  1. Occupational doses due to photoneutrons in medical linear accelerators rooms

    International Nuclear Information System (INIS)

    Soares, Alessandro Facure Neves de Salles

    2006-04-01

    Medical linear accelerators, with maximum photon energies above 10 MeV, are becoming of common use in Brazil. Although desirable in the therapeutic point of view, the increase in photon energies causes the generation of undesired neutrons, which are produced through nuclear reactions between photons and the high Z target nuclei of the materials that constitute the accelerator head. In this work, MCNP simulation was undertaken to examine the neutron equivalent doses around the accelerators head and at the entrance of medical linear accelerators treatment rooms, some of them licensed in Brazil by the National Regulatory Agency (CNEN). The simulated neutron dose equivalents varied between 2 e 26 μ Sv/Gy RX , and the results were compared with calculations performed with the use of some semi-empirical equations found in literature. It was found that the semi-empirical equations underestimate the simulated neutron doses in the majority of the cases, if compared to the simulated values, suggesting that these equations must be revised, due to the increasing number of high energy machines in the country. (author)

  2. Discussion of feasibility to carry out intensity modulated radiation therapy in conventional medical electron linear accelerator treatment rooms

    International Nuclear Information System (INIS)

    Yang Haiyou; Liu Liping; Liang Yueqin; Zhang Liang; Yu Shui

    2010-01-01

    Objective: To investigate the feasibility about the shielding effect of conventional medical electron linear accelerator treatment in the existing rooms to carry out intensity modulated radiation therapy (IMRT). Methods: The estimation model given in NCRP REPORT No. 151- S tructural Shielding Design and Evaluation for Megavoltage X-and Gamma-Ray Radiotherapy Facilities i s adopted by linking instances, which presents the calculation methods on radiation level at the ambience of megavoltage medical electron linear accelerator treatment room. Results: The radiation level, as well as the additional annual effect dose of occupational and public at the ambience of accelerator treatment room, in crease to a certain extent, when conventional medical electron linear accelerator treatment room; are used to carry out IMRT. Conclusion: It is necessary to make environmental impact assessment for conventional medical electron linear accelerator treatment rooms, which will be used to execute IMRT. (authors)

  3. Some folded issues related to over-shielded and unplanned rooms for medical linear accelerators - A case study

    Science.gov (United States)

    Muhammad, Wazir; Ullah, Asad; Hussain, Amjad; Ali, Nawab; Alam, Khan; Khan, Gulzar; Matiullah; Maeng, Seongjin; Lee, Sang Hoon

    2015-08-01

    A medical linear accelerator (LINAC) room must be properly shielded to limit the outside radiation exposure to an acceptable safe level defined by individual state and international regulations. However, along with this prime objective, some additional issues are also important. The current case-study was designed to unfold the issues related to over-shielded and unplanned treatment rooms for LINACs. In this connection, an apparently unplanned and over-shielded treatment room of 610 × 610 cm2 in size was compared with a properly designed treatment room of 762 × 762 cm2 in size ( i.e., by following the procedures and recommendations of the IAEA Safety Reports Series No. 47 and NCRP 151). Evaluation of the unplanned room indicated that it was over-shielded and that its size was not suitable for total body irradiation (TBI), although the license for such a treatment facility had been acquired for the installed machine. An overall 14.96% reduction in the total shielding volume ( i.e., concrete) for an optimally planned room as compared to a non-planned room was estimated. Furthermore, the inner room's dimensions were increased by 25%, in order to accommodate TBI patients. These results show that planning and design of the treatment rooms are imperative to avoid extra financial burden to the hospitals and to provide enough space for easy and safe handling of the patients. A spacious room is ideal for storing treatment accessories and facilitates TBI treatment.

  4. Practical high-density shielding materials for medical linear accelerator rooms

    International Nuclear Information System (INIS)

    Barish, R.J.

    1990-01-01

    High-energy linear accelerators are replacing lower energy units in radiation therapy centers. Radiation protection requirements necessitate expensive reconstruction of existing treatment rooms to accommodate these new machines. We describe two shielding materials: one made by embedding small pieces of scrap steel in cement, and the other made with cast iron in cement. Both materials produce high-density barriers at low cost using standard construction methods

  5. Application of NCRP REPORT No.151 for evaluating the radiation level at the ambience of megavoltage medical electron linear accelerator treatment room

    International Nuclear Information System (INIS)

    Yang Haiyou; Yu Shui

    2011-01-01

    Objective: The estimation model,on radiation level at the ambience of medical electron linear accelerator treatment rooms, is derived on the basis of NCRP REPORT No.151, which presents the calculation model of shielding design about barrier thicknesses of megavoltage medical electron linear accelerator treatment rooms. Methods: The estimation model comes from NCRP REPORT No.151- S tructural Shielding Design and Evaluation for Megavoltage X-and Gamma-Ray Radiotherapy Facilities , which presents the calculation model of shielding design about megavoltage medical electron linear accelerator treatment rooms, and the dose rate at isocenter replaces the workload, and the occupancy factor and the use factor are forsaken, then the converse deduction is done according to barrier thicknesses of shielding materials. Ultimately, the estimation model, on radiation level at the ambience of medical electron linear accelerator treatment rooms, is derived. Results: It can be regarded as a systematic estimation model for calculating the radiation level at the ambience of medical electron linear accelerator treatment room. Conclusion: The estimation model has certain practical value to evaluate the radiation level at the ambience of medical electron linear accelerator treatment room. (authors)

  6. Activation products in a treatment room of a 15 MV linear accelerator for medical use

    International Nuclear Information System (INIS)

    De Leon M, H. A.; Soto B, T. G.; Rivera P, E.; Hernandez D, V. M.; Vega C, H. R.

    2012-10-01

    Linacs working above 8 MV produce an undesirable neutron field mainly through (γ, n) nuclear reactions. Due to room-return effect inside the vault there is a thermal neutron flux that is constant regarded the distance to the isocenter. When thermal neutrons collide with the bunker walls and the Linac head some radioisotopes are induced in the concrete, wedges and collimators due to neutron and photon activation. The aim of this work is to study the induced radioisotopes in concrete samples and a wedge, which emits gamma-ray during its decay, the presence of this protons will represent a radiological risk for the patient. Induced radioisotopes were studied with a 15 MV Linac, and a gamma-ray spectrometer with a Nal(Tl) scintillator where 846.8, 1368.6 and 1778.8 keV gamma-rays were observed, these photons are produced during the decay of 54 Mn, 24 Na and 28 Al respectively, being in agreement with radionuclides reported in the literature. (Author)

  7. A study on optimization of photoneutron shielding in a medical accelerator room by using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Kim, Yong Nam; Jeong, Kyoungkeun; Kim, Joo Young; Lee, Chang Geol; Seong, Jinsil; Choi, Sang Hyun; Kim, Chan Hyeong

    2008-01-01

    Medical linear accelerators operating above 10 MV require door shielding for neutrons in addition to photons. A criterion for choice of optimal configuration of lamination of BPE (Borated Polyethylene) and lead is not clear. Moreover, optimal configuration cannot be determined by the conventional method using an analytical formula and simple measurement. This study performs Monte Carlo simulation of radiation field in a commercial LINAC room with 15 MV X-ray sources. Considering two configuration of lamination such as 'lead-BPE' and 'lead-BPE-lead', dose equivalents are calculated by using the MCNPX code and comparative analyses are performed with each other. The obtained results show that there is no significant difference in neuron shielding between both configurations, whereas lead-BPE-lead is more effective for photon shielding. It is also noted that the absolute values of neutron doses are much greater than that of photon doses outside as well as inside the door, by three orders of magnitude. As a conclusion, the laminating of lead-BPE is suggested as the optimal configuration from the viewpoint of simplicity in fabrication and handling, even though it has no significant difference from lead-BPE-lead in terms of total dose equivalent. (author)

  8. Occupational doses due to photoneutrons in medical linear accelerators rooms; Doses ocupacionais devido a neutrons em salas de aceleradores lineares de uso medico

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Alessandro Facure Neves de Salles

    2006-04-15

    Medical linear accelerators, with maximum photon energies above 10 MeV, are becoming of common use in Brazil. Although desirable in the therapeutic point of view, the increase in photon energies causes the generation of undesired neutrons, which are produced through nuclear reactions between photons and the high Z target nuclei of the materials that constitute the accelerator head. In this work, MCNP simulation was undertaken to examine the neutron equivalent doses around the accelerators head and at the entrance of medical linear accelerators treatment rooms, some of them licensed in Brazil by the National Regulatory Agency (CNEN). The simulated neutron dose equivalents varied between 2 e 26 {mu} Sv/Gy{sub RX}, and the results were compared with calculations performed with the use of some semi-empirical equations found in literature. It was found that the semi-empirical equations underestimate the simulated neutron doses in the majority of the cases, if compared to the simulated values, suggesting that these equations must be revised, due to the increasing number of high energy machines in the country. (author)

  9. Medical Proton Accelerator Project

    International Nuclear Information System (INIS)

    Comsan, M.N.H.

    2008-01-01

    A project for a medical proton accelerator for cancer treatment is outlined. The project is motivated by the need for a precise modality for cancer curing especially in children. Proton therapy is known by its superior radiation and biological effectiveness as compared to photon or electron therapy. With 26 proton and 3 heavy-ion therapy complexes operating worldwide only one (p) exists in South Africa, and none in south Asia and the Middle East. The accelerator of choice should provide protons with energy 75 MeV for eye treatment and 250 MeV for body treatment. Four treatment rooms are suggested: two with isocentric gantries, one with fixed beams and one for development. Passive scanning is recommended. The project can serve Middle East and North Africa with ∼ 400 million populations. The annual capacity of the project is estimated as 1,100 to be compared with expected radiation cases eligible for proton cancer treatment of not less than 200,000

  10. Personnel hazards from medical electron accelerator photoneutrons

    International Nuclear Information System (INIS)

    McCall, R.C.; Jenkins, T.M.; Shore, R.A.; LaRiviere, P.D.

    1979-12-01

    For medical accelerators, neutron penetration through the room entry door is the major personnel hazard. Most therapy accelerator rooms are designed with at least a rudimentary maze to avoid the use of massive doors. Often, however, the maze may be similar to those shown in scale outline drawings of some medical electron accelerator rooms where the authors have made neutron measurements outside the doors which were of different thicknesses and compositions. The results are tabulated. It should be noted that there can be significant dose equivalents (H) at the door when a maze is inadequate, and that all three components - fast neutron, thermal neutron, and neutron capture γ rays - can be equally important

  11. High energy medical accelerators

    International Nuclear Information System (INIS)

    Mandrillon, P.

    1990-01-01

    The treatment of tumours with charged particles, ranging from protons to 'light ions' (carbon, oxygen, neon), has many advantages, but up to now has been little used because of the absence of facilities. After the successful pioneering work carried out with accelerators built for physics research, machines dedicated to this new radiotherapy are planned or already in construction. These high energy medical accelerators are presented in this paper. (author) 15 refs.; 14 figs.; 8 tabs

  12. Medical uses of accelerators

    International Nuclear Information System (INIS)

    Bradbury, J.N.

    1981-01-01

    A variety of particle accelerators have either potential or already demonstrated uses in connection with medically-related research, diagnosis, and treatment. For cancer radiotherapy, nuclear particles including protons, neutrons, heavy ions, and negative pi mesons have advantages compared to conventional radiations in terms of dose localization and/or biological effectiveness. Clinical evaluations of these particles are underway at a number of institutions. Accelerator-produced radionuclides are in widespread use for research and routine diagnostic purposes. Elemental analysis techniques with charged particles and neutrons are being applied to bone, blood, and other tissues. Finally, low-dose medical imaging can be accomplished with accelerated protons and heavy ions. The status and future of these programs are discussed

  13. Medical applications of accelerators

    CERN Document Server

    Rossi, Sandro

    1998-01-01

    At Present, about five thousands accelerators are devoted to biomedical applications. They are mainly used in radiotherapy, research and medical radioisotopes production. In this framework oncological hadron-therapy deserves particular attention since it represents a field in rapid evolution thanks to the joint efforts of laboratories with long experiences in particle physics. It is the case of CERN where the design of an optimised synchrotron for medical applications has been pursued. These lectures present these activities with particular attention to the new developments which are scientifically interesting and/or economically promising.

  14. Heavy ion medical accelerator, HIMAC

    International Nuclear Information System (INIS)

    Yamada, Satoru

    1993-01-01

    The heavy ion beam is undoutedly suitable for the cancer treatment. The supriority of the heavy ions over the conventional radiations including protons and neutrons comes mainly from physical characteristics of a heavy particle with multiple charges. A straggling angle due to a multiple Coulomb scattering process in a human body is small for heavy ions, and the small scattering angle results in a good dose localization in a transverse direction. An ionization ratio of the heavy ion beam makes a very sharp peak at the ends of their range. The height of the peak is higher for the heavier ions and shows excellent biomedical effects around Ne ions. In order to apply heavy ion beams to cancer treatment, Heavy Ion Medical Accelerator in Chiba (HIMAC) has been constructed at National Institute of Radiological Sciences. The accelerator complex consists of two ion sources, two successive linac tanks, a pair of synchrotron rings, a beam transport system and an irradiation system. An operation frequency is 100 MHz for two linacs, and the ion energy is 6.0 MeV/u at the output end of the linac. The other four experimental rooms are prepared for basic experiments. The synchrotron accelerates ions up to 800 MeV/u for a charge to mass ratio of 1/2. The long beam transport line provides two vertical beams in addition with two horizontal beams for the treatment. The three treatment rooms are prepared one of which is equipped with both horizontal and vertical beam lines. The whole facility will be open for all scientists who have interests in the heavy ion science as well as the biophysics. The conceptual design study of HIMAC started in 1984, and the construction of the accelerator complex was begun in March 1988. The beam acceleration tests of the injector system was successfully completed in March of this year, and tests of the whole system will be finished throughout this fyscal year. (author)

  15. Advanced Accelerators for Medical Applications

    Science.gov (United States)

    Uesaka, Mitsuru; Koyama, Kazuyoshi

    We review advanced accelerators for medical applications with respect to the following key technologies: (i) higher RF electron linear accelerator (hereafter “linac”); (ii) optimization of alignment for the proton linac, cyclotron and synchrotron; (iii) superconducting magnet; (iv) laser technology. Advanced accelerators for medical applications are categorized into two groups. The first group consists of compact medical linacs with high RF, cyclotrons and synchrotrons downsized by optimization of alignment and superconducting magnets. The second group comprises laser-based acceleration systems aimed of medical applications in the future. Laser plasma electron/ion accelerating systems for cancer therapy and laser dielectric accelerating systems for radiation biology are mentioned. Since the second group has important potential for a compact system, the current status of the established energy and intensity and of the required stability are given.

  16. Accelerator development for medical applications

    International Nuclear Information System (INIS)

    Tanabe, Eiji

    2007-01-01

    Electron linear accelerators have been widely used in medical applications, especially in radiation therapy for cancer treatment. There are more than 7,000 medical electron linear accelerators in the world, treating over 250,000 patients per day. This paper reviews the current status of accelerator applications and technologies in radiation therapy, and presents the anticipated requirements for advanced radiation therapy technology in the foreseeable future. (author)

  17. Measurement of the radiation in the accelerator-therapy room

    International Nuclear Information System (INIS)

    Zutz, Hayo

    2013-01-01

    The measurement of the scattering radiation in the accelerator-therapy room of the PTB is described. The accelerators are commercial linear accelerators of the firm Elektra of the type ''Precise''. The measurements were performed by means of secondary-normal ionization chambers and a special measurement technique developed in the PTB both with and without the used beam. (HSI)

  18. Compact accelerator for medical therapy

    Science.gov (United States)

    Caporaso, George J.; Chen, Yu-Jiuan; Hawkins, Steven A.; Sampayan, Stephen E.; Paul, Arthur C.

    2010-05-04

    A compact accelerator system having an integrated particle generator-linear accelerator with a compact, small-scale construction capable of producing an energetic (.about.70-250 MeV) proton beam or other nuclei and transporting the beam direction to a medical therapy patient without the need for bending magnets or other hardware often required for remote beam transport. The integrated particle generator-accelerator is actuable as a unitary body on a support structure to enable scanning of a particle beam by direction actuation of the particle generator-accelerator.

  19. Neutrons from medical electron accelerators

    International Nuclear Information System (INIS)

    Swanson, W.P.; McCall, R.C.

    1979-06-01

    The significant sources of photoneutrons within a linear-accelerator treatment head are identified and absolute estimates of neutron production per treatment dose are given for typical components. Measured data obtained at a variety of accelerator installations are presented and compared with these calculations. It is found that the high-Z materials within the treatment head do not significantly alter the neutron fluence, but do substantially reduce the average energy of the transmitted spectrum. Reflected neutrons from the concrete treatment room contribute to the neutron fluence, but not substantially to the patient integral dose, because of a further reduction in average energy. Absolute depth-dose distributions for realistic neutron spectra are calculated, and a rapid falloff with depth is found

  20. Basis of medical accelerator. Synchrotron

    International Nuclear Information System (INIS)

    Kawachi, Kiyomitsu

    2014-01-01

    On the synchrotron as a medical accelerator, this paper introduces the basic principle, basic techniques and the like. The accelerator, when synchrotron is adopted as an ion beam radiotherapy system, is the composite accelerator composed of ion sources, injector, and synchrotron. This paper introduces the overall structure of synchrotron, and conceptually explains the basic behavior of high-frequency waves and magnetic field of synchrotron, as well as the deflection electromagnet of medical synchrotron and the operation pattern of high-frequency acceleration system. The types of synchrotron can be classified to the function combination type and function separation type, and this paper introduces the features of each type and various types of synchrotrons. It also explains beam dynamics important for ensuring the stability of beams, with a focus on the coordinate system, vertical movement, and lateral movement. In addition, it explains the incidence and outgoing of beams that are important for properly operating the accelerator, with a focus on their techniques. (A.O.)

  1. Medical heavy ion accelerator proposals

    International Nuclear Information System (INIS)

    Gough, R.A.

    1985-05-01

    For several decades, accelerators designed primarily for research in nuclear and high energy physics have been adapted for biomedical research including radiotherapeutic treatment of human diseases such as pituitary disorders, cancer, and more recently, arteriovascular malformations. The particles used in these treatments include pions, protons and heavier ions such as carbon, neon, silicon and argon. Maximum beam energies must be available to penetrate into an equivalent of about 30 cm of water, requiring treatment beams of 250 to 1000 MeV/nucleon. Certain special treatments of superficial melanoma, however, require that beam energies as low as 70 MeV/nucleon also be available. Intensities must be adequate to complete a 100 rad treatment fraction in about 1 minute. For most heavy ion treatments, this corresponds to 10 7 -10 9 ions/second at the patient. Because this research is best conducted in a dedicated, hospital-based facility, and because of the clinical need for ultra-high reliability, the construction of new and dedicated facilities has been proposed. Heavy ion accelerators can provide a variety of ions and energies, permitting treatment plans that exploit the properties of the ion best suited to each individual treatment, and that employ radioactive beams (such as 11 C and 19 Ne) to precisely confirm the dose localization. The favored technical approach in these proposals utilizes a conventional, strong-focusing synchrotron capable of fast switching between ions and energies, and servicing multiple treatment rooms. Specialized techniques for shaping the dose to conform to irregularly-shaped target volumes, while simultaneously sparing surrounding, healthy tissue and critical structures, are employed in each treatment room, together with the sophisticated dosimetry necessary for verification, monitoring, and patient safety. 3 refs., 8 figs

  2. Moonshot Acceleration Factor: Medical Imaging.

    Science.gov (United States)

    Sevick-Muraca, Eva M; Frank, Richard A; Giger, Maryellen L; Mulshine, James L

    2017-11-01

    Medical imaging is essential to screening, early diagnosis, and monitoring responses to cancer treatments and, when used with other diagnostics, provides guidance for clinicians in choosing the most effective patient management plan that maximizes survivorship and quality of life. At a gathering of agency officials, patient advocacy organizations, industry/professional stakeholder groups, and clinical/basic science academicians, recommendations were made on why and how one should build a "cancer knowledge network" that includes imaging. Steps to accelerate the translation and clinical adoption of cancer discoveries to meet the goals of the Cancer Moonshot include harnessing computational power and architectures, developing data sharing policies, and standardizing medical imaging and in vitro diagnostics. Cancer Res; 77(21); 5717-20. ©2017 AACR . ©2017 American Association for Cancer Research.

  3. Personnel hazards from medical electron accelerator photoneutrons

    International Nuclear Information System (INIS)

    Mcall, R.C.; Jenkins, T.M.; Shore, R.A.; LaRiviere, P.D.

    1980-01-01

    Medical electron accelerators operated in the photon mode produce significant amounts of photoneutrons at energies above 15 MeV. There can be definite radiation problems at doors of treatment rooms where operating consoles are often located. These problems are due in large part to inadequate maze design by physicists unaccustomed to shielding against neutrons. The radiation field at the door is an unusual combination of low energy neutrons, thermal neutrons and capture γ-rays from the concrete walls of the maze and the door itself. While this radiation field is dependent upon the actual construction details, these three components each contribute roughly one-third of the total dose equivalent. Reducing these high radiation levels presents a formidable problem. The neutrons can be absorbed by hydrogenous material which can be attached to the door, but the neutron capture γ-rays would require massive amounts of lead for the required attenuation. Both measurements and Monte Carlo calculations are presented to illustrate the problem. Some possible shielding solutions are presented for pre-existing treatment rooms, as well as design recommendations for new rooms. (H.K.)

  4. Application of accelerator in the medical aspects

    International Nuclear Information System (INIS)

    Shi Lisheng; Wang Bairong; Yang Zhongping

    2014-01-01

    In recent years, the human life span compared with before there is an obvious increase in. With the extension of life, cancer incidence is increasing, at the same time, the diagnosis and treatment of cancer has been the development of. Based on the review of the past and present situation of diagnosis and treatment of cancer, the accelerator and the future to introduce, divided into the accelerator treatment, cancer diagnosis, accelerator accelerator with radioactive isotopes, medical accelerator conditions and medical accelerator built five content. (authors)

  5. Accelerator for medical applications and electron acceleration by laser plasma

    International Nuclear Information System (INIS)

    Hosokai, Tomonao; Uesaka, Mitsuru

    2006-01-01

    In this article, the current status of radiation therapies in Japan and updated medical accelerators are reviewed. For medical use, there is a strong demand of a compact and flexible accelerator. At present, however, we have only two choices of the S-band linac with one or two rotation axis combined with the multi leaf collimator, or the X-band linac with a rather flexible robotic arm. In addition, the laser plasma cathode that is the second generation of the laser wake-field accelerator (LWFA) is studied as a high-quality electron source for medical use though it is still at the stage of the basic research. The potential of LWFA as medical accelerator near future is discussed based on updated results of laser plasma cathode experiment in Univ. of Tokyo. (author)

  6. Applications of Particle Accelerators in Medical Physics

    OpenAIRE

    Cuttone, G

    2008-01-01

    Particle accelerators are often associated to high energy or nuclear physics. As well pointed out in literature [1] if we kindly analyse the number of installation worldwide we can easily note that about 50% is mainly devoted to medical applications (radiotherapy, medical radioisotopes production, biomedical research). Particle accelerators are also playing an important indirect role considering the improvement of the technical features of medical diagnostic. In fact the use of radionuclide f...

  7. Neutron radiation from medical electron accelerators

    International Nuclear Information System (INIS)

    McCall, R.C.

    1983-01-01

    A method is described using simple gold foils and relatively inexpensive moderators to measure neutron fluences, both fast nd thermal, which then can be converted to dose equivalent using a few simple formulas. The method is sensitive, easy to calibrate, and should work at most accelerators regardless of energy or room geometry

  8. Shielding calculation for treatment rooms of high energy linear accelerator

    International Nuclear Information System (INIS)

    Elleithy, M.A.

    2006-01-01

    A review of German Institute of Standardization (DIN) scheme of the shielding calculation and the essential data required has been done for X-rays and electron beam in the energy range from 1 MeV to 50 MeV. Shielding calculation was done for primary and secondary radiations generated during X-ray operation of Linac. In addition, shielding was done against X-rays generated (Bremsstrahlung) by useful electron beams. The calculations also covered the neutrons generated from the interactions of useful X-rays (at energies above 8 MeV) with the surrounding. The present application involved the computation of shielding against the double scattered components of X-rays and neutrons in the maze area and the thickness of the paraffin wax of the room door. A new developed computer program was designed to assist shielding thickness calculations for a new Linac installation or in replacing an existing machine. The program used a combination of published tables and figures in computing the shielding thickness at different locations for all possible radiation situations. The DIN published data of 40 MeV accelerator room was compared with the program calculations. It was found that there is good agreement between both calculations. The developed program improved the accuracy and speed of calculation

  9. Ion sources for medical accelerators

    Science.gov (United States)

    Barletta, W. A.; Chu, W. T.; Leung, K. N.

    1998-02-01

    Advanced injector systems for proton synchrotrons and accelerator-based boron neutron capture therapy systems are being developed at the Lawrence Berkeley National Laboratory. Multicusp ion sources, particularly those driven by radio frequency, have been tested for these applications. The use of a radio frequency induction discharge provides clean, reliable, and long-life source operation. It has been demonstrated that the multicusp ion source can provide good-quality positive hydrogen ion beams with a monatomic ion fraction higher than 90%. The extractable ion current densities from this type of source can meet the injector requirements for both proton synchrotron and accelerator-based boron neutron capture therapy projects.

  10. Consumer opinions of emergency room medical care.

    Science.gov (United States)

    McMillan, J R; Younger, M S; DeWine, L C

    1984-12-01

    If hospital management is to adapt successfully to an increasingly competitive environment, and to retain a viable emergency department, it well be necessary to objectively and accurately assess the hospital's image in the community served. Knowledge of the consumers' views is an essential input into the formulation of strategic plans. This article reports on a study in which consumer opinions on 15 dimensions of emergency room health care were obtained from 723 respondents using a mail questionnaire. Findings reveal that consumers view the emergency room as being more expensive than other health care providers. Except for being available or convenient, little or no advantage is perceived for the emergency room over the personal physician. Even though the emergency room has specialized staff and equipment, consumers do not believe patients receive better or faster treatment in an emergency room than would be obtained in a physician's office. Unless changed, these perceptions will diminish the role of the emergency room in the delivery of health care services.

  11. Occupational dose due to neutrons in medical linear accelerators

    International Nuclear Information System (INIS)

    Larcher, Ana M.; Bonet Duran, Stella M.; Lerner, Ana M.

    2000-01-01

    This paper describes a semi-empirical method to calculate the occupational dose due to neutrons and capture gamma rays in medical linear accelerators. It compares theoretical dose values with measurements performed in several 15 MeV medical accelerators installed in the country. Good agreement has been found between calculations made using the model and dose measurements, except for those accelerator rooms in which the maze length was shorter than the postulated tenth value distance. For those cases the model seems to overestimate neutron dose. The results demonstrate that the semi-empirical model is a good tool for quick and conservative shielding calculations for radiation protection purposes. Nevertheless, it is necessary to continue with the measurements in order to perform a more accurate validation of the model. (author)

  12. Accelerators for Medical Applications What is so Special?

    CERN Document Server

    Schippers, J.M.

    2016-01-01

    Specific requirements of accelerators for radiation therapy with protons or ions will be discussed. The focus will be on accelerator design, operational and formal aspects. We will discuss the special requirements to reach a high reliability for patient treatments as well as an accurate delivery of the dose at the correct position in the patient using modern techniques like pencil beam scanning. It will be shown that the requirements of the accelerated beam differ from those in a nuclear physics laboratory. The way of operating such a medical device requires not only operators, but also the possibility to have a safe machine operation by non accelerator specialists at different operating sites (treatment rooms). It will be shown that the organisation and role of the control/interlock system can be considered as being the most dedicated in a particle-therapy providing facility.

  13. Applications of Particle Accelerators in Medical Physics

    CERN Document Server

    Cuttone, G

    2008-01-01

    Particle accelerators are often associated to high energy or nuclear physics. As well pointed out in literature [1] if we kindly analyse the number of installation worldwide we can easily note that about 50% is mainly devoted to medical applications (radiotherapy, medical radioisotopes production, biomedical research). Particle accelerators are also playing an important indirect role considering the improvement of the technical features of medical diagnostic. In fact the use of radionuclide for advanced medical imaging is strongly increasing either in conventional radiography (CT and MRI) and also in nuclear medicine for Spect an PET imaging. In this paper role of particle accelerators for medical applications will be presented together with the main solutions applied.

  14. Special radiation protection aspects of medical accelerators

    CERN Document Server

    Silari, Marco

    2001-01-01

    Radiation protection aspects relevant to medical accelerators are discussed. An overview is first given of general safety requirements. Next. shielding and labyrinth design are discussed in some detail for the various types of accelerators, devoting more attention to hadron machines as they are far less conventional than electron linear accelerators. Some specific aspects related to patient protection are also addressed. Finally, induced radioactivity in accelerator components and shielding walls is briefly discussed. Three classes of machines are considered: (1) medical electron linacs for 'conventional' radiation therapy. (2) low energy cyclotrons for production of radionuclides mainly for medical diagnostics and (3) medium energy cyclotrons and synchrotrons for advanced radiation therapy with protons or light ion beams (hadron therapy). (51 refs).

  15. Neutron yield of medical electron accelerators

    International Nuclear Information System (INIS)

    McCall, R.C.

    1988-01-01

    Shielding calculations for medical electron accelerators above about 10 MeV require some knowledge of the neutron emission from the machine. This knowledge might come from the manufacturer's specifications or from published measurements of the neutron leakage of that particular model and energy of accelerator. In principle, the yield can be calculated if details of the accelerator design are known. These details are often not available because the manufacturer considers them proprietary. A broader knowledge of neutron emission would be useful and it is the purpose of this paper to present such information

  16. Stabilisation Evaluation of Medical Linear Accelerator

    International Nuclear Information System (INIS)

    Nasukha

    1996-01-01

    Medical linear accelerator are widely used for cancer treatment in radiotherapy. Radiation beam stability of accelerators, Megatron 20 and 12 were evaluated for a month with RMI daily constancy tool. Un stability less than 3 % for 7,10,12,15,18 MeV of electron beam and photon beam 15MV of Megatron 20 and photon beam 12MV of Megatron 12. Electron beam of 5 MeV of Megatron 20 should be set to get better salability, especially its radiofrequency

  17. Heavy ion medical accelerator in chiba

    International Nuclear Information System (INIS)

    Hirao, Y.; Ogawa, H.; Yamada, S.

    1992-12-01

    The HIMAC (Heavy Ion Medical Accelerator in Chiba) construction project has been promoted by NIRS (National Institute of Radiological Sciences) as one of the projects of 'Comprehensive 10 year Strategy for Cancer Control' HIMAC is the first heavy-ion accelerator dedicated to medicine in the world, and its design parameters are based on the radiological requirements. It consists of two types of ion sources, an RFQ and an Alvarez linacs, dual synchrotron rings, high energy beam transport lines, and irradiation facilities for treatment and experiments. This report mainly describes the outline of the structure and performance of each HIMAC subsystem. (J.P.N.)

  18. The neutron dose equivalent around high energy medical electron linear accelerators

    Directory of Open Access Journals (Sweden)

    Poje Marina

    2014-01-01

    Full Text Available The measurement of neutron dose equivalent was made in four dual energy linear accelerator rooms. Two of the rooms were reconstructed after decommissioning of 60Co units, so the main limitation was the space. The measurements were performed by a nuclear track etched detectors LR-115 associated with the converter (radiator that consist of 10B and with the active neutron detector Thermo BIOREM FHT 742. The detectors were set at several locations to evaluate the neutron ambient dose equivalent and/or neutron dose rate to which medical personnel could be exposed. Also, the neutron dose dependence on collimator aperture was analyzed. The obtained neutron dose rates outside the accelerator rooms were several times smaller than the neutron dose rates inside the accelerator rooms. Nevertheless, the measured neutron dose equivalent was not negligible from the aspect of the personal dosimetry with almost 2 mSv a year per person in the areas occupied by staff (conservative estimation. In rooms with 15 MV accelerators, the neutron exposure to the personnel was significantly lower than in the rooms having 18 MV accelerators installed. It was even more pronounced in the room reconstructed after the 60Co decommissioning. This study confirms that shielding from the neutron radiation should be considered when building vaults for high energy linear accelerators, especially when the space constraints exist.

  19. Dedicated medical ion accelerator design study. Final report

    International Nuclear Information System (INIS)

    1977-12-01

    Results and conclusions are reported from a design study for a dedicated medical accelerator. Basing efforts on the current consensus regarding medical requirements, the resulting demands on accelerator and beam delivery systems were analyzed, and existing accelerator technology was reviewed to evaluate the feasibility of meeting these demands. This general analysis was augmented and verified by preparing detailed preliminary designs for sources of therapeutic beams of neutrons, protons and heavy ions. The study indicates that circular accelerators are the most desirable and economical solutions for such sources. Synchrotrons are clearly superior for beams of helium and heavier ions, while synchrotrons and cyclotrons seem equally well suited for protons although they have different strengths and weaknesses. Advanced techniques of beam delivery are of utmost importance in fully utilizing the advantages of particle beams. Several issues are invloved here. First, multi-treatment room arrangements are essential for making optimal use of the high dose rate capabilities of ion accelerators. The design of corresponding beam switching systems, the principles of which are already developed for physics experimental areas, pose no problems. Second, isocentric beam delivery substantially enhances flexibility of dose delivery. After several designs for such devices were completed, it was concluded that high field magnets are necessary to keep size, bulk and cost acceptable. Third, and most important, is the generation of large, homogeneous radiation fields. This is presently accomplished with the aid of scattering foils, occluding rings, collimators, ridge filters, and boluses. A novel approach, three-dimensional beam scanning, was developed here, and the most demanding components of such a system (fast-scanning magnet and power supply) were built and tested

  20. Discussion on the optimization design on mazes of medical linear accelerator facilities

    International Nuclear Information System (INIS)

    Cao Lei; Zhang Wenyi; Liu Baiqun; Hou Changsong; Zhao Lancai

    2007-01-01

    Objective: To discuss the differences on the design and evaluation between the L-type and Z-type mazes of typical medical electric linear accelerator. Methods: The study is conducted by choosing some typical medical electric linear accelerators used in China, further analyzing on the running conditions of the accelerators in the mode of MV-X-ray, and referring to the late NCRP Report 51 and other references. Results: The radiation levels at the access to therapy room are effectively reduced by Z-type mazes. Conclusions: The Z-type mazes are advisable during the optimization design. (authors)

  1. Accelerator Production of Isotopes for Medical Use

    Science.gov (United States)

    Lapi, Suzanne

    2014-03-01

    The increase in use of radioisotopes for medical imaging and therapy has led to the development of novel routes of isotope production. For example, the production and purification of longer-lived position emitting radiometals has been explored to allow for nuclear imaging agents based on peptides, antibodies and nanoparticles. These isotopes (64Cu, 89Zr, 86Y) are typically produced via irradiation of solid targets on smaller medical cyclotrons at dedicated facilities. Recently, isotope harvesting from heavy ion accelerator facilities has also been suggested. The Facility for Rare Isotope Beams (FRIB) will be a new national user facility for nuclear science to be completed in 2020. Radioisotopes could be produced by dedicated runs by primary users or may be collected synergistically from the water in cooling-loops for the primary beam dump that cycle the water at flow rates in excess of hundreds of gallons per minute. A liquid water target system for harvesting radioisotopes at the National Superconducting Cyclotron Laboratory (NSCL) was designed and constructed as the initial step in proof-of-principle experiments to harvest useful radioisotopes in this manner. This talk will provide an overview of isotope production using both dedicated machines and harvesting from larger accelerators typically used for nuclear physics. Funding from Department of Energy under DESC0007352 and DESC0006862.

  2. A Miracle That Accelerates Operating Room Functionality: Sugammadex

    Directory of Open Access Journals (Sweden)

    Erdal Dogan

    2014-01-01

    Full Text Available Background. Sugammadex offers a good alternative to the conventional decurarisation process currently performed with cholinesterase inhibitors. Sugammadex, which was developed specifically for the aminosteroid-structured rocuronium and vecuronium neuromuscular blockers, is a modified cyclodextrin made up of 8 glucose monomers arranged in a cylindrical shape. Methods. In this study, the goal was to investigate the efficacy of sugammadex. Sugammadex was used when there was insufficient decurarisation following neostigmine. This study was performed on 14 patients who experienced insufficient decurarisation (TOF <0.9 with neostigmine after general anaesthesia in the operating rooms of a university and a state hospital between June, 2012, and January, 2014. A dose of 2 mg/kg of sugammadex was administered. Results. Time elapsed until sugammadex administration following neostigmine 37 ± 6 min, following sugammadex it took 2.1 ± 0.9 min to reach TOF ≥ 0.9, and the extubation time was 3.2 ± 1.4 min. No statistically significant differences were detected in the hemodynamic parameters before and after sugammadex application. From the time of administration of sugammadex to the second postoperative hour, no side effects or complications occurred. None of the patients experienced acute respiratory failure or residual block during this time period. Conclusion. Sugammadex was successfully used to reverse rocuronium-induced neuromuscular block in patients where neostigmine was insufficient.

  3. Research on cw electron accelerators using room-temperature rf structures: Annual report

    International Nuclear Information System (INIS)

    1986-01-01

    This joint NBS-Los Alamos project of ''Research on CW Electron Accelerators Using Room-Temperature RF Structures'' began seven years ago with the goal of developing a technology base for cw electron accelerators. In this report we describe our progress during FY 1986 and present our plans for completion of the project. First, however, it is appropriate to review the past contributions of the project, describe its status, and indicate its future benefits

  4. Variables influencing medical student learning in the operating room.

    Science.gov (United States)

    Schwind, Cathy J; Boehler, Margaret L; Rogers, David A; Williams, Reed G; Dunnington, Gary; Folse, Roland; Markwell, Stephen J

    2004-02-01

    The operating room (OR) is an important venue where surgeons do much of medical student teaching and yet there has been little work evaluating variables that influence learning in this unique environment. We designed this study to identify variables that affected medical student learning in the OR. We developed a questionnaire based on surgery faculty observations of learning in the OR. The medical students completed the questionnaire on 114 learning episodes in the OR. Pearson correlation coefficient was used to establish the strength of association between various variables and the student's overall perception of learning. The students evaluated 27 variables that might impact their learning in the OR. Strong correlations were identified between the attending physician's attitude, interactions and teaching ability in the OR and the environment being conducive to learning. Surgical faculty behavior is a powerful determinant of student perceptions of what provides for a favorable learning environment in the OR.

  5. [Technical Gap of Chinese Medical Accelerator and Its Development Path].

    Science.gov (United States)

    Tian, Xinzhi

    2017-11-30

    With the reform and opening up the tide through nearly four decades of development, our medical accelerator business isfacing new era demands now, in this new historical opportunity in front of the younger generation of medical accelerator staff must assume the older generation of scientific research personnel are different of the historical responsibility. Based on the development of the predecessors, we try to analyze the current situation of the domestic accelerator, establish the new development ideas of the domestic medical accelerator, and directly face and solve the dilemma facing the development of the domestic accelerator.

  6. Shielding design for the target room of the proton accelerator research center

    International Nuclear Information System (INIS)

    Min, Y. S.; Lee, C. W.; Mun, K. J.; Nam, J.; Kim, J. Y.

    2010-01-01

    The Proton Engineering Frontier Project (PEFP) has been developing a 100-MeV proton linear accelerator. Also, PEFP has been designing the Proton Accelerator Research Center (PARC). In the Accelerator Tunnel and Beam Experiment Hall in PARC, 10 target rooms for the 20- and 100-MeV beamline facilities exist in the Beam Experiment Hall. For the 100-MeV target rooms during 100-MeV proton beam extraction, a number of high energy neutrons, ranging up to 100-MeV, are produced. Because of the high beam current and space limitations of each target room, the shielding design of each target room should be considered seriously. For the shielding design of the 100-MeV target rooms of the PEFP, a permanent and removable local shield structure was adopted. To optimize shielding performance, we evaluated four different shield materials (concrete, HDPE, lead, iron). From the shielding calculation results, we confirmed that the proposed shielding design made it possible to keep the dose rate below the 'as low as reasonably achievable (ALARA)' objective.

  7. Evaluation of accelerated stability test conditions for medicated chewing gums.

    Science.gov (United States)

    Maggi, Lauretta; Conte, Ubaldo; Nhamias, Alain; Grenier, Pascal; Vergnault, Guy

    2013-10-01

    The overall stability of medicated chewing gums is investigated under different storage conditions. Active substances with different chemical stabilities in solid state are chosen as model drugs. The dosage form is a three layer tablet obtained by direct compression. The gum core contains the active ingredient while the external layers are formulated to prevent gum adhesion to the punches of the tableting machine. Two accelerated test conditions (40°C/75% RH and 30°C/65% RH) are performed for 6 months. Furthermore, a long-term stability test at room conditions is conducted to verify the predictability of the results obtained from the stress tests. Some drugs are stable in all the conditions tested, but other drugs, generally considered stable in solid dosage forms, have shown relevant stability problems particularly when stress test conditions are applied to this particular semi-solid dosage forms. For less stable drugs, the stress conditions of 40°C/75% RH are not always predictable of chewing gum stability at room temperature and may produce false negative; intermediate conditions, 30°C/65% RH, are more predictive for this purpose, the results of drug content found after 6 months at intermediate stress conditions and 12 months at room conditions are generally comparable. But the results obtained show that only long-term conditions stability tests gave consistent results. During aging, the semi solid nature of the gum base itself, may also influence the drug delivery rate during chewing and great attention should be given also to the dissolution stability.

  8. Characteristics of induced activity from medical linear accelerators

    International Nuclear Information System (INIS)

    Wang Yizhen; Evans, Michael D.C.; Podgorsak, Ervin B.

    2005-01-01

    A study of the induced activity in a medical linear accelerator (linac) room was carried out on several linac installations. Higher beam energy, higher dose rate, and larger field size generally result in higher activation levels at a given point of interest, while the use of multileaf collimators (MLC) can also increase the activation level at the isocenter. Both theoretical and experimental studies reveal that the activation level in the morning before any clinical work increases from Monday to Saturday and then decreases during the weekend. This weekly activation picture keeps stable from one week to another during standard clinical operation of the linac. An effective half-life for a given point in the treatment room can be determined from the measured or calculated activity decay curves. The effective half-life for points inside the treatment field is longer than that for points outside of the field in the patient plane, while a larger field and longer irradiation time can also make the effective half-life longer. The activation level reaches its practical saturation value after a 30 min continuous irradiation, corresponding to 12 000 MU at a 'dose rate' of 400 MU/min. A 'dose' of 300 MU was given 20 times in 15 min intervals to determine the trends in the activation level in a typical clinical mode. As well, a long-term (85 h over a long weekend) decay curve was measured to evaluate the long-term decay of room activation after a typical day of clinical linac use. A mathematical model for the activation level at the isocenter has been established and shown to be useful in explaining and predicting the induced activity levels for typical clinical and experimental conditions. The activation level for a 22 MeV electron beam was also measured and the result shows it is essentially negligible

  9. A versatile program for the calculation of linear accelerator room shielding.

    Science.gov (United States)

    Hassan, Zeinab El-Taher; Farag, Nehad M; Elshemey, Wael M

    2018-03-22

    This work aims at designing a computer program to calculate the necessary amount of shielding for a given or proposed linear accelerator room design in radiotherapy. The program (Shield Calculation in Radiotherapy, SCR) has been developed using Microsoft Visual Basic. It applies the treatment room shielding calculations of NCRP report no. 151 to calculate proper shielding thicknesses for a given linear accelerator treatment room design. The program is composed of six main user-friendly interfaces. The first enables the user to upload their choice of treatment room design and to measure the distances required for shielding calculations. The second interface enables the user to calculate the primary barrier thickness in case of three-dimensional conventional radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT) and total body irradiation (TBI). The third interface calculates the required secondary barrier thickness due to both scattered and leakage radiation. The fourth and fifth interfaces provide a means to calculate the photon dose equivalent for low and high energy radiation, respectively, in door and maze areas. The sixth interface enables the user to calculate the skyshine radiation for photons and neutrons. The SCR program has been successfully validated, precisely reproducing all of the calculated examples presented in NCRP report no. 151 in a simple and fast manner. Moreover, it easily performed the same calculations for a test design that was also calculated manually, and produced the same results. The program includes a new and important feature that is the ability to calculate required treatment room thickness in case of IMRT and TBI. It is characterised by simplicity, precision, data saving, printing and retrieval, in addition to providing a means for uploading and testing any proposed treatment room shielding design. The SCR program provides comprehensive, simple, fast and accurate room shielding calculations in radiotherapy.

  10. SU-E-T-270: Optimized Shielding Calculations for Medical Linear Accelerators (LINACs).

    Science.gov (United States)

    Muhammad, W; Lee, S; Hussain, A

    2012-06-01

    The purpose of radiation shielding is to reduce the effective equivalent dose from a medical linear accelerator (LINAC) to a point outside the room to a level determined by individual state/international regulations. The study was performed to design LINAC's room for newly planned radiotherapy centers. Optimized shielding calculations were performed for LINACs having maximum photon energy of 20 MV based on NCRP 151. The maximum permissible dose limits were kept 0.04 mSv/week and 0.002 mSv/week for controlled and uncontrolled areas respectively by following ALARA principle. The planned LINAC's room was compared to the already constructed (non-optimized) LINAC's room to evaluate the shielding costs and the other facilities those are directly related to the room design. In the evaluation process it was noted that the non-optimized room size (i.e., 610 × 610 cm 2 or 20 feet × 20 feet) is not suitable for total body irradiation (TBI) although the machine installed inside was having not only the facility of TBI but the license was acquired. By keeping this point in view, the optimized INAC's room size was kept 762 × 762 cm 2. Although, the area of the optimized rooms was greater than the non-planned room (i.e., 762 × 762 cm 2 instead of 610 × 610 cm 2), the shielding cost for the optimized LINAC's rooms was reduced by 15%. When optimized shielding calculations were re-performed for non-optimized shielding room (i.e., keeping room size, occupancy factors, workload etc. same), it was found that the shielding cost may be lower to 41 %. In conclusion, non- optimized LINAC's room can not only put extra financial burden on the hospital but also can cause of some serious issues related to providing health care facilities for patients. © 2012 American Association of Physicists in Medicine.

  11. Simulation of a medical linear accelerator for teaching purposes.

    Science.gov (United States)

    Anderson, Rhys; Lamey, Michael; MacPherson, Miller; Carlone, Marco

    2015-05-08

    Simulation software for medical linear accelerators that can be used in a teaching environment was developed. The components of linear accelerators were modeled to first order accuracy using analytical expressions taken from the literature. The expressions used constants that were empirically set such that realistic response could be expected. These expressions were programmed in a MATLAB environment with a graphical user interface in order to produce an environment similar to that of linear accelerator service mode. The program was evaluated in a systematic fashion, where parameters affecting the clinical properties of medical linear accelerator beams were adjusted independently, and the effects on beam energy and dose rate recorded. These results confirmed that beam tuning adjustments could be simulated in a simple environment. Further, adjustment of service parameters over a large range was possible, and this allows the demonstration of linear accelerator physics in an environment accessible to both medical physicists and linear accelerator service engineers. In conclusion, a software tool, named SIMAC, was developed to improve the teaching of linear accelerator physics in a simulated environment. SIMAC performed in a similar manner to medical linear accelerators. The authors hope that this tool will be valuable as a teaching tool for medical physicists and linear accelerator service engineers.

  12. Role of accelerator science and technology in medical science

    International Nuclear Information System (INIS)

    Uesaka, Mitsuru

    2006-01-01

    Updated status of compact and advanced-compact medical accelerator development is reviewed. In their applications, medical physics and medical physicist are necessary. Their educational programs have started in several universities and institutes. As one important new trend on life-science, the research on the synergy of DDS (Drug Delivery System) and physical energies are proposed. (author)

  13. RF linear accelerators for medical and industrial applications

    CERN Document Server

    Hanna, Samy

    2012-01-01

    This unique resource offers you a clear overview of medical and industrial accelerators. Using minimal mathematics, this book focuses on offering thorough explanations of basic concepts surrounding the operation of accelerators. you find well illustrated discussions designed to help you use accelerator-based systems in a safer, more productive, and more reliable manner.This practical book details the manufacturing process for producing accelerators for medical and industrial applications. You become knowledgeable about the commonly encountered real-world manufacturing issues and potential sources of defects which help you avoid costly production problems. From principles of operation and the role of accelerators in cancer radiation therapy, to manufacturing techniques and future trends in accelerator design and applications, this easy-to-comprehend volume quickly brings you up-to-speed with the critical concepts you need to understand for your work in the field.

  14. Presentation of a semiempirical method for the calculation of doses due to neutrons and capture gamma rays inside high energy accelerators rooms

    International Nuclear Information System (INIS)

    Larcher, A.M.; Bonet Duran, S.M.

    1998-01-01

    Full text: Medical electron accelerators operating above 10 MeV produce radiation beams that are contaminated with neutrons. Therefore, shielding design for high energy accelerator rooms must consider the neutron component of the radiation field. In this paper a semiempirical method is presented to calculate doses due to neutrons and capture gamma rays inside the room and the maze. The calculation method is based on the knowledge of the neutron yield Q (neutrons/Gy of photons at isocenter) and the average energy of the primary beam of neutrons Eo (MeV). The method constitutes an appropriate tool for shielding facilities evaluation. The accuracy of the method has been contrasted with data obtained from the literature and an excellent correlation among the calculations and the measured values was achieved. In addition, the method has been used in the verification of experimental data corresponding to a 15 MeV linear accelerator installed in the country with similar results. (author) [es

  15. The application of accelerator for medical therapy in Indonesia

    International Nuclear Information System (INIS)

    Yunasfi; Mudjiono; Irwati, Dwi; Hanifa

    2003-01-01

    The study of the application of accelerator for medical therapy in Indonesia was carried out. Accelerator that used for therapy is an electron lintier accelerator (Linac) which can radiate electron beam and X-ray. This study shows that there are 8 unit of Linac distributed at 6 big hospitals in Indonesia, especially in Jakarta. This study also shows that radiotherapy facilities in Indonesia is un sufficient of. Therefore, providing radiotherapy facilities for hospitals, especially the big hospitals in Indonesia is necessary

  16. A beam-matching concept for medical linear accelerators

    DEFF Research Database (Denmark)

    Sjöström, David; Bjelkengren, Ulf; Ottosson, Wiviann

    2009-01-01

    The flexibility in radiotherapy can be improved if a patient can be moved between any one of the department's medical linear accelerators without the need to change anything in the patient's treatment plan. For this to be possible, the dosimetric characteristics of the various accelerators must...

  17. Neutron fluence produced in medical accelerators

    International Nuclear Information System (INIS)

    Castro, R.C.; Silva, A.X. da; Crispim, V.R.

    2004-01-01

    Radiotherapy with photon and electron beams still represents the most diffused technique to control and treat tumour diseases. To increase the treatment efficiency, accelerators of higher energy are used, the increase of electron and photon energy is joined with generation of undesired fast neutron that contaminated the therapeutic beam and give a non-negligible contribution to the patient dose. In this work we have simulated with the MCNP4B code the produced neutron spectra in the interaction between the beam and the head to the accelerator and estimating the equivalent dose for neutrons by x-ray dose for aims far from the targets. (author)

  18. Reaction of Medical Students to Experiences in Dissection Room ...

    African Journals Online (AJOL)

    Conclusion: The present study findings show that smell of the dissection room, touch and fear of cadaver were the commonest cause of their symptoms experienced while study in dissection room for the majority of students. Thus, instructors are should give awareness raising education before the commencement of the ...

  19. If additional shielding required for the linear accelerator room when modern treatment techniques are intensively used

    International Nuclear Information System (INIS)

    Miller, Albert V.; Atkocius, Vydmantas; Aleknavicius, Eduardas

    2001-01-01

    Full text: Introduction - When the new linear accelerator is to be installed in radiotherapy department the responsible personnel should perform necessary estimations and calculations of the protective barriers for the accelerator treatment room. These methods are described in details in literature. However, if modern treatment techniques are planned to be intensively used on this machine, additional concern rises regarding adequacy of these calculations. The new Saturne-43 linear accelerator with three photon energies of 8, 15 and 25 MV recently installed at our department was, planned to be used for conventional treatment techniques as well as for conformal and total body treatments. The method of conformal therapy generally employs more small fields per one treated patient than conventional techniques. It leads to the use of more linear accelerator monitor units for the average treatment. It was estimated that 'beam on' time of an accelerator to deliver the same dose to the tumor is up to 3 times more than for conventional methods. The total body technique contribute to the extra time on of an accelerator because of extended distance to the dose prescription point. Altogether intensive clinical use of these modern techniques will noticeably increase 'beam on' time of an accelerator and rise question regarding validity of the traditionally calculated shielding of the treatment room. Materials and methods - IAEA-TECDOC-1040 and NCRP Report No 49 suggest considering three main components incident on the protective barriers: direct radiation, scatter radiation and leakage radiation. The formulas for these components are similar and dose equivalent limits are proportional to the workload. For the conventional treatments workloads of direct, scattered and leakage radiation are equal and calculated by the division of total prescribed dose (for all treated per week patients) to the machine isocenter to average tissue maximum ratio. These workloads for conformal and TBI

  20. Distribution of residual long-lived radioactivity in the inner concrete walls of a compact medical cyclotron vault room.

    Science.gov (United States)

    Fujibuchi, Toshioh; Nohtomi, Akihiro; Baba, Shingo; Sasaki, Masayuki; Komiya, Isao; Umedzu, Yoshiyuki; Honda, Hiroshi

    2015-01-01

    Compact medical cyclotrons have been set up to generate the nuclides necessary for positron emission tomography. In accelerator facilities, neutrons activate the concrete used to construct the vault room; this activation increases with the use of an accelerator. The activation causes a substantial radioactive waste management problem when facilities are decommissioned. In the present study, several concrete cores from the walls, ceiling and floor of a compact medical cyclotron vault room were samples 2 years after the termination of operations, and the radioactivity concentrations of radionuclides were estimated. Cylindrical concrete cores 5 cm in diameter and 10 cm in length were bored from the concrete wall, ceiling and floor. Core boring was performed at 18 points. The gamma-ray spectrum of each sample was measured using a high-purity germanium detector. The degree of activation of the concrete in the cyclotron vault room was analyzed, and the range and tendency toward activation in the vault room were examined. (60)Co and (152)Eu were identified by gamma-ray spectrometry of the concrete samples. (152)Eu and (60)Co are produced principally from the stable isotopes of europium and cobalt by neutron capture reactions. The radioactivity concentration did not vary much between the surface of the concrete and at a depth of 10 cm. Although the radioactivity concentration near the target was higher than the clearance level for radioactive waste indicated in IAEA RS-G-1.7, the mean radioactivity concentration in the walls and floor was lower than the clearance level. The radioactivity concentration of the inner concrete wall of the medical cyclotron vault room was not uniform. The areas exceeding the clearance level were in the vicinity of the target, but most of the building did not exceed the clearance levels.

  1. Engineering Prototype for a Compact Medical Dielectric Wall Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Zografos, Anthony; Hening, Andy; Joshkin, Vladimir; Leung, Kevin; Pearson, Dave; Pearce-Percy, Henry; Rougieri, Mario; Parker, Yoko; Weir, John [CPAC, Livermore, CA (United States); Blackfield, Donald; Chen, Yu-Jiuan; Falabella, Steven; Guethlein, Gary; Poole, Brian [Lawrence Livermore National Laboratory, Livermore, CA (United States); Hamm, Robert W. [R and M Technical Enterprises, Pleasanton, CA (United States); Becker, Reinard [Scientific Software Service, Gelnhausen (Germany)

    2011-12-13

    A compact accelerator system architecture based on the dielectric wall accelerator (DWA) for medical proton beam therapy has been developed by the Compact Particle Acceleration Corporation (CPAC). The major subsystems are a Radio Frequency Quadrupole (RFQ) injector linac, a pulsed kicker to select the desired proton bunches, and a DWA linear accelerator incorporating a high gradient insulator (HGI) with stacked Blumleins to produce the required acceleration energy. The Blumleins are switched with solid state laser-driven optical switches integrated into the Blumlein assemblies. Other subsystems include a high power pulsed laser, fiber optic distribution system, electrical charging system, and beam diagnostics. An engineering prototype has been constructed and characterized, and these results will be used within the next three years to develop an extremely compact 150 MeV system capable of modulating energy, beam current, and spot size on a shot-to-shot basis. This paper presents the details the engineering prototype, experimental results, and commercialization plans.

  2. Engineering Prototype for a Compact Medical Dielectric Wall Accelerator

    International Nuclear Information System (INIS)

    Zografos, Anthony; Hening, Andy; Joshkin, Vladimir; Leung, Kevin; Pearson, Dave; Pearce-Percy, Henry; Rougieri, Mario; Parker, Yoko; Weir, John; Blackfield, Donald; Chen, Yu-Jiuan; Falabella, Steven; Guethlein, Gary; Poole, Brian; Hamm, Robert W.; Becker, Reinard

    2011-01-01

    A compact accelerator system architecture based on the dielectric wall accelerator (DWA) for medical proton beam therapy has been developed by the Compact Particle Acceleration Corporation (CPAC). The major subsystems are a Radio Frequency Quadrupole (RFQ) injector linac, a pulsed kicker to select the desired proton bunches, and a DWA linear accelerator incorporating a high gradient insulator (HGI) with stacked Blumleins to produce the required acceleration energy. The Blumleins are switched with solid state laser-driven optical switches integrated into the Blumlein assemblies. Other subsystems include a high power pulsed laser, fiber optic distribution system, electrical charging system, and beam diagnostics. An engineering prototype has been constructed and characterized, and these results will be used within the next three years to develop an extremely compact 150 MeV system capable of modulating energy, beam current, and spot size on a shot-to-shot basis. This paper presents the details the engineering prototype, experimental results, and commercialization plans.

  3. Evaluation of neutron doses beyond of primary shielding of rooms housing clinical linear accelerators

    International Nuclear Information System (INIS)

    Rezende, Gabriel Fonseca da Silva

    2011-01-01

    The growing need to build radiotherapy rooms in places with lack of available space leads to the necessity of unconventional solutions for the shielding projects. In most cases, adding metals to the primary barriers is the best way to shield the rooms properly. However, when photons with energies equal to or great than 10 MeV interact with nuclei of materials with high atomic number, neutrons are ejected and can result in a problem of radioprotection both inside and outside the room. Currently, the only empirical formula existing in the literature to assess the dose equivalent due to neutrons beyond the laminated barriers works only under very specific conditions, and a validation of this formula had not yet been done. In this work, the Monte Carlo code MCNPX was used to verify the validity of the above formula for cases of primary barriers containing lead or iron sheets in rooms that house linear accelerators with 10, 15 and 18 MV. Moreover, such a code was used to evaluate the coefficient of neutron production and tenth-value layer for neutrons in concrete, both parameters that directly influence the equation studied. The study results showed that over 90% of the values compared between the formula and the simulations present discrepancies above 100%, which led to conclude that the formula from the literature produces values that do not match the reality. In addition, there were inconsistencies in the parameters that make up the formula, leading to a need to review this formula in order to build a new model that will better represent the real case. (author)

  4. Report of the Study Group on Medical Uses of Accelerators

    International Nuclear Information System (INIS)

    1978-01-01

    Medical uses of accelerators to raise the welfare of peoples are advancing rapidly due to the improvement of using technology. Under the situation, the Study Group on Medical Uses of Accelerators set up in the Science and Technology Agency has surveyed the status in Japan of radiation therapy of cancers and nuclear medicine with accelerators, and has studied on the future research and development in this field. The present report should contribute to the plans by the Government for the future. The results obtained by the study Group are described: the trends of medicine for the next ten years, especially the advances of cancer diagnosis and treatment and nuclear medicine; and medical radiation sources and the accelerators as their generators expected to be in practical utilization. As for the particles from accelerators used for medical purposes, there are fast neutrons, protons, helium particles, charged heavy particles, and π-mesons. For diagnosis and treatment, the radiation sources must be chosen according to the purposes, and their combination becomes necessary. (Mori, K.)

  5. CAS Accelerators for Medical Applications in Vösendorf, Austria

    CERN Multimedia

    CERN Accelerator School

    2015-01-01

    The CERN Accelerator School (CAS) and MedAustron jointly organised a course on Accelerators for Medical Applications in Vösendorf, Austria between 26 May and 5 June 2015. The course was held at the Eventhotel Pyramide on the outskirts of Vienna, and was attended by 76 participants from 29 countries, coming from as far away as Canada, China, Lithuania, Thailand, Ukraine and Russia.       The intensive programme comprised 37 lectures. The emphasis was on using charged particle beams for cancer therapy and the programme began by covering the way in which particles interact with biological material, how this translates into the dose needed for treatment and how this dose is best delivered. The different accelerator options for providing the particles needed were then presented in some detail. The production of radioisotopes and how these are used for diagnostics and therapy was also covered, together with a look at novel acceleration techniques that may play a role i...

  6. Design and construction of the clean room for proton beam accelerator assembly

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. S.; Song, I. T

    2000-09-01

    The objective of this report is to design, construction and evaluation of clean room for proton beam accelerator assembly. The design conditions o Class : 1,000(1,000 ea ft{sup 3}), o Flow Rate : 200 m{sup 3}/h m{sup 2}, o Temperature : 22 deg C{+-}2, o Humidity : 55%{+-}5. The main design results are summarized as follows: o Air-handling unit : Cooling Capacity : 13,500 kcal/h, Heating Capacity : 10,300 kcal/h, Humidity Capacity : 4 kg/h, Flow Rate : 150 CMM o Air Shower : Flow Rate : 35 CMM, Size : 1500 x 1000 x 2200, Material : In-steel, Out-SUS304, Filter : PRE + HEPA, AIR Velocity : 25 m/s o Relief Damper : Size : {phi}250, Casing : SS41, Blade : AL, Shaft : SUS304, Weight Ring : SS41, Grill : AL o HEPA Filter Box : Filter Box Size : 670 x 670 x 630, Filter Size : 610 x 610 x 150, Frame: Poly Wood, Media : Glass Fiber, Filter Efficiency : 0.3{mu}m, 99.97%, Separator : AL, Flow Rate : 17 CMM, Damper Size : {phi}300 Following this report will be used important data for the design, construction, operation and maintenance of the clean room, for high precision apparatus assembly laboratory.

  7. Design and construction of the clean room for proton beam accelerator assembly

    International Nuclear Information System (INIS)

    Park, J. S.; Song, I. T.

    2000-09-01

    The objective of this report is to design, construction and evaluation of clean room for proton beam accelerator assembly. The design conditions o Class : 1,000(1,000 ea ft 3 ), o Flow Rate : 200 m 3 /h m 2 , o Temperature : 22 deg C±2, o Humidity : 55%±5. The main design results are summarized as follows: o Air-handling unit : Cooling Capacity : 13,500 kcal/h, Heating Capacity : 10,300 kcal/h, Humidity Capacity : 4 kg/h, Flow Rate : 150 CMM o Air Shower : Flow Rate : 35 CMM, Size : 1500 x 1000 x 2200, Material : In-steel, Out-SUS304, Filter : PRE + HEPA, AIR Velocity : 25 m/s o Relief Damper : Size : Φ250, Casing : SS41, Blade : AL, Shaft : SUS304, Weight Ring : SS41, Grill : AL o HEPA Filter Box : Filter Box Size : 670 x 670 x 630, Filter Size : 610 x 610 x 150, Frame: Poly Wood, Media : Glass Fiber, Filter Efficiency : 0.3μm, 99.97%, Separator : AL, Flow Rate : 17 CMM, Damper Size : Φ300 Following this report will be used important data for the design, construction, operation and maintenance of the clean room, for high precision apparatus assembly laboratory

  8. Proposed medical applications of the National Accelerator Centre facilities

    International Nuclear Information System (INIS)

    Jones, D.T.L.

    1982-01-01

    The National Accelerator Centre is at present under construction at Faure, near Cape Town. The complex will house a 200 MeV separated-sector cyclotron which will provide high quality beams for nuclear physics and related diciplines as well as high intensity beams for medical use. The medical aspects catered for will include particle radiotherapy, isotope production and possibly proton radiography. A 30-bed hospital is to be constructed on the site. Building operations are well advanced and the medical facilities should be available for use by the end of 1984

  9. The final technical report of the CRADA, 'Medical Accelerator Technology'

    International Nuclear Information System (INIS)

    Chu, W.T.; Rawls, J.M.

    2000-01-01

    Under this CRADA, Berkeley Lab and the industry partner, General Atomics (GA), have cooperatively developed hadron therapy technologies for commercialization. Specifically, Berkeley Lab and GA jointly developed beam transport systems to bring the extracted protons from the accelerator to the treatment rooms, rotating gantries to aim the treatment beams precisely into patients from any angle, and patient positioners to align the patient accurately relative to the treatment beams. We have also jointly developed a patient treatment delivery system that controls the radiation doses in the patient, and hardware to improve the accelerator performances, including a radio-frequency ion source and its low-energy beam transport (LEBT) system. This project facilitated the commercialization of the DOE-developed technologies in hadron therapy by the private sector in order to improve the quality of life of the nation

  10. An examination of medical linear accelerator ion-chamber performance

    International Nuclear Information System (INIS)

    Karolis, C.; Lee, C.; Rinks, A.

    1996-01-01

    Full text: The company ( Radiation Oncology Physics and Engineering Services Pty Ltd) provides medical physics services to four radiotherapy centres in NSW with a total of 6 high energy medical linear accelerators manufactured by three different companies. As part of the services, the stability of the accelerator ion chamber system is regularly examined for constancy and periodically for absolute calibration. Each accelerator ion chamber has exhibited undesirable behaviour from time to time, sometimes leading to its replacement. This presentation describes the performance of the ion chambers for some of the linacs over a period of 12-18 months and the steps taken by the manufacturer to address the problems encountered. As part of our commissioning procedure of new linacs, an absolute calibration of the accelerator output (photon and electron beams) is repeated several times over the period following examination of the physical properties of the radiation beams. These calibrations were undertaken in water using the groups calibrated ion chamber/electrometer system and were accompanied by constancy checks using an acrylic phantom and field instruments. Constancy checks were performed daily for a period of 8 weeks during the initial life of the accelerator and thereafter weekly. For one accelerator, the ion chamber was replaced 6 times in the first eighteen months of its life due to severe drifts in output, found to be due to pressure changes in one half of the chamber In another accelerator, erratic swings of 2% were observed for a period of nine months, particularly with the electron beams, before the manufacturer offered to change the chamber with another constructed from different materials. In yet another accelerator the ion chamber has shown consistent erratic behaviour, but this has not been addressed by the manufacturer. In another popular accelerator, the dosimetry was found to be very stable until some changes in the tuning were introduced resulting in small

  11. Current heavy particle medical accelerator programs in Japan

    International Nuclear Information System (INIS)

    Kawachi, K.

    1987-01-01

    The first clinical trial of proton radiotherapy in Japan started at National Institute of Radiological Sciences (NIRS) in 1979. The proton which is provided from the NIRS medical cyclotron, has an energy of 70 MeV, and has been used for only superficial or short range tumor therapy. Recently, the cyclotron has been raised the energy up to 90 MeV and a vertical treatment line of protons has been completed in the basement of the cyclotron building. In 1983, Particle Radiation Medical Science Center (PARMS) of the University of Tsukuba started to treat patients with 250 MeV proton beam. The Institute of Physical and Chemical Research (IPCR) has a plan to construct a heavy ion biomedical irradiation facility in the Ring (Separate Sector) Cyclotron building. The facility will be completed in 1989 and will be used for proton and helium ion therapy. Recently, several hospitals have proposed to construct the dedicated proton therapy facilities. The National Cancer Center of Japan, and the PARMS of the University of Tsukuba have taken active parts in such projects. At present time, there is a step to make a decision of the type of accelerators. Another program is a construction of the NIRS Heavy Particle Medical Accelerator which is possible to provide Helium to Argon ions for therapy. The paper describes the accelerators for proton therapy and for heavy ion therapy in some detail

  12. [Design and Implementation of a Mobile Operating Room Information Management System Based on Electronic Medical Record].

    Science.gov (United States)

    Liu, Baozhen; Liu, Zhiguo; Wang, Xianwen

    2015-06-01

    A mobile operating room information management system with electronic medical record (EMR) is designed to improve work efficiency and to enhance the patient information sharing. In the operating room, this system acquires the information from various medical devices through the Client/Server (C/S) pattern, and automatically generates XML-based EMR. Outside the operating room, this system provides information access service by using the Browser/Server (B/S) pattern. Software test shows that this system can correctly collect medical information from equipment and clearly display the real-time waveform. By achieving surgery records with higher quality and sharing the information among mobile medical units, this system can effectively reduce doctors' workload and promote the information construction of the field hospital.

  13. Invisible victims: battered women in psychiatric and medical emergency rooms.

    Science.gov (United States)

    Keller, L E

    1996-01-01

    Violence against women by their male partners is widespread and infrequently identified as a causal factor in multiple physical and psychological problems of female patients in medical and psychiatric settings. Three main countertransferences that interfere with accurate identification of battered women are described: (1) counter- identification, (2)countertransference rage, and (3) countertransference helplessness. Battering men and battered women are found in all levels of society, although younger, lower income, less-educated men who have observed parental violence in their own home are at higher risk of abusing their spouses. Additionally, antisocial personality disorder, depression, and/or alcohol and drug abuse increase the risk of male violence in the home. Contrary to popular belief, the husband-to-wife violence is usually motivated by his need to control her rather than a result of his loss of control. Battered women show no consistent prebattering risk markers, except for a history of parental violence in their family of origin. Violence against women by their male partners is a serious public health problem that has not been adequately addressed by the medical and psychiatric professions. Myths and clinical realities of battered women are described and detailed recommendations for clinical inquiry and evaluation of level of danger are given.

  14. Clinical nutrition in medical gastroenterology: room for improvement

    DEFF Research Database (Denmark)

    Johansson, U.; Rasmussen, H.H.; Mowe, M.

    2009-01-01

    BACKGROUND & AIMS: Undernutrition is a problem in hospitals, with lack of nutritional routines. Recently, guidelines concerning the nutritional care process were developed from ESPEN. This study was conducted to assess the present status of nutritional routines among doctors and nurses in internal...... medicine (IM) and medical gastroenterology (MG), in comparison with the ESPEN guidelines. METHOD: A questionnaire-based investigation among doctors and nurses working in departments of internal medicine and gastroenterology in Scandinavia, based on further analysis of previous data. RESULTS: Overall, 4512...... (1753 doctors, 2759 nurses) answered the questionnaire, of which 1155 were from internal medicine and 193 from gastroenterology. A similar, non-significant, discrepancy in attitudes and nutritional routines was noted in gastroenterologists and internists. Concerning basic nutritional education, 46...

  15. Closed-loop approach for situation awareness of medical devices and operating room infrastructure

    Directory of Open Access Journals (Sweden)

    Rockstroh Max

    2015-09-01

    Full Text Available In recent years, approaches for information and control integration in the digital operating room have emerged. A major step towards an intelligent operating room and a cooperative technical environment would be autonomous adaptation of medical devices and systems to the surgical workflow. The OR staff should be freed from information seeking and maintenance tasks. We propose a closed-loop concept integrating workflow monitoring, processing and (semi-automatic interaction to bridge the gap between OR integration of medical devices and workflow-related information management.

  16. Smartphone application for mechanical quality assurance of medical linear accelerators.

    Science.gov (United States)

    Kim, Hwiyoung; Lee, Hyunseok; Park, Jong In; Choi, Chang Heon; Park, So-Yeon; Kim, Hee Jung; Kim, Young Suk; Ye, Sung-Joon

    2017-06-07

    Mechanical quality assurance (QA) of medical linear accelerators consists of time-consuming and human-error-prone procedures. We developed a smartphone application system for mechanical QA. The system consists of two smartphones: one attached to a gantry for obtaining real-time information on the mechanical parameters of the medical linear accelerator, and another displaying real-time information via a Bluetooth connection with the former. Motion sensors embedded in the smartphone were used to measure gantry and collimator rotations. Images taken by the smartphone's high-resolution camera were processed to evaluate accuracies of jaw-positioning, crosshair centering and source-to-surface distance (SSD). The application was developed using Android software development kit and OpenCV library. The accuracy and precision of the system was validated against an optical rotation stage and digital calipers, prior to routine QA measurements of five medical linear accelerators. The system accuracy and precision in measuring angles and lengths were determined to be 0.05  ±  0.05° and 0.25  ±  0.14 mm, respectively. The mean absolute errors (MAEs) in QA measurements of gantry and collimator rotation were 0.05  ±  0.04° and 0.05  ±  0.04°, respectively. The MAE in QA measurements of light field was 0.39  ±  0.36 mm. The MAEs in QA measurements of crosshair centering and SSD were 0.40  ±  0.35 mm and 0.41  ±  0.32 mm, respectively. In conclusion, most routine mechanical QA procedures could be performed using the smartphone application system with improved precision and within a shorter time-frame, while eliminating potential human errors.

  17. Shielding for neutrons produced by medical linear accelerators

    International Nuclear Information System (INIS)

    Rebello, Wilson F.; Silva, Ademir X.

    2007-01-01

    The shielding system called Multileaf Shielding (MLS) was designed in Brazil to be used for protection patients, who undergo radiotherapy treatment, against undesired neutrons produced in the medical linear accelerator heads. During the conceiving of the MLS it was necessary to evaluate its efficiency. For that purpose, several simulations using the Monte Carlo N-particle radiation transport code, MCNP5, were made, in order to evaluate the response of the new shielding system. The results showed a significant neutron dose reduction after the inclusion of the MLS. This work aims to presenting these simulation results. (author)

  18. Some advances in medical applications of low energy accelerators

    Science.gov (United States)

    Valković, V.; Moschini, G.

    1991-05-01

    Medical applications of low energy accelerators include: the use of nuclear analytical methods and procedures for laboratory studies and routine measurements; material productions and modifications to meet special requirements; radioisotope productions and their applications in radiopharmaceuticals as well as in positron emission tomography; and radiotherapy with ions, based on improved understanding of the interaction of charged particles with living tissue. Some of the recent advances in these fields are critically summarized. The plan for an improved charged particle facility in a hospital environment dedicated to applications in biology and medicine is presented.

  19. On isocentre adjustment and quality control in linear accelerator based radiosurgery with circular collimators and room lasers

    Energy Technology Data Exchange (ETDEWEB)

    Treuer, H. [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany). E-mail: h.treuer at uni-koeln.de; Hoevels, M.; Luyken, K.; Gierich, A.; Sturm, V. [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Kocher, M.; Mueller, R.-P. [Department of Radiotherapy, University of Cologne, Cologne (Germany)

    2000-08-01

    We have developed a densitometric method for measuring the isocentric accuracy and the accuracy of marking the isocentre position for linear accelerator based radiosurgery with circular collimators and room lasers. Isocentric shots are used to determine the accuracy of marking the isocentre position with room lasers and star shots are used to determine the wobble of the gantry and table rotation movement, the effect of gantry sag, the stereotactic collimator alignment, and the minimal distance between gantry and table rotation axes. Since the method is based on densitometric measurements, beam spot stability is implicitly tested. The method developed is also suitable for quality assurance and has proved to be useful in optimizing isocentric accuracy. The method is simple to perform and only requires a film box and film scanner for instrumentation. Thus, the method has the potential to become widely available and may therefore be useful in standardizing the description of linear accelerator based radiosurgical systems. (author)

  20. On isocentre adjustment and quality control in linear accelerator based radiosurgery with circular collimators and room lasers

    International Nuclear Information System (INIS)

    Treuer, H.; Kocher, M.; Mueller, R.-P.

    2000-01-01

    We have developed a densitometric method for measuring the isocentric accuracy and the accuracy of marking the isocentre position for linear accelerator based radiosurgery with circular collimators and room lasers. Isocentric shots are used to determine the accuracy of marking the isocentre position with room lasers and star shots are used to determine the wobble of the gantry and table rotation movement, the effect of gantry sag, the stereotactic collimator alignment, and the minimal distance between gantry and table rotation axes. Since the method is based on densitometric measurements, beam spot stability is implicitly tested. The method developed is also suitable for quality assurance and has proved to be useful in optimizing isocentric accuracy. The method is simple to perform and only requires a film box and film scanner for instrumentation. Thus, the method has the potential to become widely available and may therefore be useful in standardizing the description of linear accelerator based radiosurgical systems. (author)

  1. Operation of medical accelerator PATRO at Hyogo Ion Beam Medical Center

    International Nuclear Information System (INIS)

    Itano, A.; Akagi, T.; Higashi, A.; Fukushima, S.; Fujita, A.; Honda, Y.; Isa, H.; Nishikigouri, K.

    2004-01-01

    PATRO (Particle Accelerator for Therapy, Radiology and Oncology) is a medical accelerator facility for hadrontherapy of cancer at Hyogo Ion Beam Medical Center (HIBMC). Beam particles are proton (230 MeV) and carbon (320 MeV/u). After the beam commissioning and the tuning of irradiation system in 2000, we performed the clinical trials with proton and carbon beams from May 2001 until July 2002. We operated the accelerator for about 11,000 hours since the beginning of the beam tuning until the end of the clinical trials and for about 5,000 hours during the clinical trials. No serious troubles happened during the clinical trials. The stability and the reproducibility of the beams were well proved. (author)

  2. Flexibility in hospital building and application by means of standardized medical room types

    NARCIS (Netherlands)

    Kamp, Pieter; Kooistra, Rien; Ankersmid, H.A.H.G.; Bonnema, Gerrit Maarten

    2014-01-01

    This paper presents an approach to standardization of hospital rooms. As hospitals are becoming more complex, the need for quality assurance and validation increases as well. Several sources mention the responsibility of the medical personnel for the quality and safety of the equipment with which

  3. Re-Shielding of Cobalt-60 Teletherapy Rooms for Tomotherapy and Conventional Linear Accelerators using Monte Carlo Simulations

    Science.gov (United States)

    Çeçen, Yiğit; Yazgan, Çağrı

    2017-09-01

    Purpose. Nearly all Cobalt-60 teletherapy machines were removed around the world during the last two decades. The remaining ones are being used for experimental purposes. However, the rooms of these teletherapy machines are valuable because of lack of space in radiotherapy clinics. In order to place a new technology treatment machine in one of these rooms, one should re-shield the room since it was designed only for 1.25 MeV gamma beams on average. Mostly, the vendor of the new machine constructs the new shielding of the room using their experience. However, every radiotherapy room has different surrounding work areas and it would be wise to shield the room considering these special conditions. Also, the shield design goal of the clinic may be much lower than the International Atomic Energy Agency (IAEA) or the local association accepts. The study shows re-shielding of a Cobalt-60 room, specific to the clinic, using Monte Carlo simulations. Materials & Methods: First, a 6 MV Tomotherapy machine, then a 10 MV conventional linear accelerator (LINAC) was placed inside the Cobalt-60 teletherapy room. The photon flux outside the room was simulated using Monte Carlo N-Particle (MCNP6.1) code before and after re-shielding. For the Tomotherapy simulation, flux distributions around the machine were obtained from the vendor and implemented as the source of the model. The LINAC model was more generic with the 10 MeV electron source, the tungsten target, first and secondary collimators. The aim of the model was to obtain the maximum (40x40 cm2) open field at the isocenter. Two different simulations were carried out for gantry angles 90o and 270o. The LINAC was placed in the room such that the primary walls were A' (Gantry 270o) and C' (Gantry 90o) (figure 1). The second part of the study was to model the re-shielding of the room for Tomotherapy and for the conventional LINAC, separately. The aim was to investigate the recommended shielding by the vendors. Left side of the room

  4. Smartphone application for mechanical quality assurance of medical linear accelerators

    Science.gov (United States)

    Kim, Hwiyoung; Lee, Hyunseok; In Park, Jong; Choi, Chang Heon; Park, So-Yeon; Kim, Hee Jung; Kim, Young Suk; Ye, Sung-Joon

    2017-06-01

    Mechanical quality assurance (QA) of medical linear accelerators consists of time-consuming and human-error-prone procedures. We developed a smartphone application system for mechanical QA. The system consists of two smartphones: one attached to a gantry for obtaining real-time information on the mechanical parameters of the medical linear accelerator, and another displaying real-time information via a Bluetooth connection with the former. Motion sensors embedded in the smartphone were used to measure gantry and collimator rotations. Images taken by the smartphone’s high-resolution camera were processed to evaluate accuracies of jaw-positioning, crosshair centering and source-to-surface distance (SSD). The application was developed using Android software development kit and OpenCV library. The accuracy and precision of the system was validated against an optical rotation stage and digital calipers, prior to routine QA measurements of five medical linear accelerators. The system accuracy and precision in measuring angles and lengths were determined to be 0.05  ±  0.05° and 0.25  ±  0.14 mm, respectively. The mean absolute errors (MAEs) in QA measurements of gantry and collimator rotation were 0.05  ±  0.04° and 0.05  ±  0.04°, respectively. The MAE in QA measurements of light field was 0.39  ±  0.36 mm. The MAEs in QA measurements of crosshair centering and SSD were 0.40  ±  0.35 mm and 0.41  ±  0.32 mm, respectively. In conclusion, most routine mechanical QA procedures could be performed using the smartphone application system with improved precision and within a shorter time-frame, while eliminating potential human errors.

  5. Accelerating physician workforce transformation through competitive graduate medical education funding.

    Science.gov (United States)

    Goodman, David C; Robertson, Russell G

    2013-11-01

    Graduate medical education (GME) has fallen short in training physicians to meet changes in the US population and health care delivery systems. The shortfall in training has happened despite a consensus on the need for accelerated change. This article discusses the varied causes of GME inertia and proposes a new funding mechanism coupled to a competitive peer-review process. The result would be to reward GME programs that are aligned with publicly set priorities for specialty numbers and training content. New teaching organizations and residency programs would compete on an equal footing with existing ones. Over a decade, all current programs would undergo peer review, with low review scores leading to partial, but meaningful, decreases in funding. This process would incentivize incremental and continual change in GME and would provide a mechanism for funding innovative training through special requests for proposals.

  6. Can Accelerators Meet the Medical Isotopes Needs of the World?

    Science.gov (United States)

    Ruth, Thomas

    2011-10-01

    Over 80% of all Nuclear Medicine procedures make use of the radionuclide Tc-99 for SPECT imaging of heart disease, cancer and other disorders. Historically TC-99 has been produced from a generator through the decay of Mo-99 where the Mo-99 is a fission product of U-235. Five reactors around the world supply the market. However, these reactors are aging (many over 50 years old) and governments are reluctant to replace them. Therefore researchers have turned to accelerators as a potential source of this important radionuclide. In Canada the government has funded research project for two accelerator approaches: Mo-100(gamma,n)Mo-99 and Mo-100(p,2n)Tc-99m where the photons are generated from the conversion of high powered electrons into Bremsstrahlung radiation and the protons generated in low energy cyclotrons (15-25 MeV). The goal of these project is to provide the Government with sufficient information so that an informed decision can be made with respect to future supplies of medical isotopes for Canada. International interest has been expressed by the IAEA as a way to allow Member States with existing cyclotron programs to take advantage of the direct production route. This talk will describe the challenges with the approaches and the progress to date.

  7. Industrial and medical applications of accelerators with energies less than 20 MeV

    International Nuclear Information System (INIS)

    Duggan, J.L.

    1983-01-01

    In this paper the medical and industrial application of small accelerators is reviewed. Most of the material is taken from the Seventh Conference on the Application of Accelerators in Research and Industry, which was held in Denton, Texas in November of 1982. The areas covered include medical linacs, cyclotron design and production of medical radioisotopes, radiation processing, ion implantation for the metallurgical and semiconductor industries, oil and mineral exploration, trace, surface and bulk analysis, and unique accelerators for all of the above applications

  8. Occupational radiation protection around medical linear accelerators: measurements and semi-analytical approaches

    International Nuclear Information System (INIS)

    Donadille, L.; Derreumaux, S.; Mantione, J.; Robbes, I.; Trompier, F.; Amgarou, K.; Asselineau, B.; Martin, A.

    2008-01-01

    Full text: X-rays produced by high-energy (larger than 6 MeV) medical electron linear accelerators create secondary neutron radiation fields mainly by photonuclear reactions inside the materials of the accelerator head, the patient and the walls of the therapy room. Numerous papers were devoted to the study of neutron production in medical linear accelerators and resulting decay of activation products. However, data associated to doses delivered to workers in treatment conditions are scarce. In France, there are more than 350 external radiotherapy facilities representing almost all types of techniques and designs. IRSN carried out a measurement campaign in order to investigate the variation of the occupational dose according the different encountered situations. Six installations were investigated, associated with the main manufacturers (Varian, Elekta, General Electrics, Siemens), for several nominal energies, conventional and IMRT techniques, and bunker designs. Measurements were carried out separately for neutron and photon radiation fields, and for radiation associated with the decay of the activation products, by means of radiometers, tissue-equivalent proportional counters and spectrometers (neutron and photon spectrometry). They were performed at the positions occupied by the workers, i.e. outside the bunker during treatments, inside between treatments. Measurements have been compared to published data. In addition, semi-empirical analytical approaches recommended by international protocols were used to estimate doses inside and outside the bunkers. The results obtained by both approaches were compared and analysed. The annual occupational effective dose was estimated to about 1 mSv, including more than 50 % associated with the decay of activation products and less than 10 % due to direct exposure to leakage neutrons produced during treatments. (author)

  9. Accelerating Energy Efficiency Improvements in Room Air Conditioners in India: Potential, Costs-Benefits, and Policies

    OpenAIRE

    Abhyankar, N; Shah, N; Park, WY; Phadke, AA

    2017-01-01

    Rising incomes, increasing urbanization, and large cooling demand prompted by India’s hot, humid climate are driving increasing uptake of room air conditioners (ACs). Air conditioning already accounts for 40-60% of summer peak load in large Indian cities such as Delhi and is on track to contribute 140 gigawatts (GW) ( 30%) to peak demand in 2030. India’s standards and labeling policies improved the market average efficiency of room ACs by about 35% between 2006 and 2016 (3% per year) even as ...

  10. Structural shielding of medical X-ray rooms for diagnostic installations

    International Nuclear Information System (INIS)

    Rabitsch, H.

    1979-06-01

    In Part I (RIG 8), the various design procedures for shielding against X-rays are discussed and compared. In particular, this comparison is carried out between the shielding obtained conforming to the Austrian Regulations for Radiation Protection and that obtained from the DIN-standard DIN 6812; this latter includes the various operating conditions of diagnostic installations up to 150 kV. Several examples for particular structural shielding components in medical radiation rooms are given. (author)

  11. Building a Smooth Medical Service for Operating Room Using RFID Technologies

    Directory of Open Access Journals (Sweden)

    Lun-Ping Hung

    2014-01-01

    Full Text Available Due to the information technology advancement, the feasibility for the establishment of mobile medical environments has been strengthened. Using RFID to facilitate the tracing of patients’ mobile position in hospital has attracted more attentions from researchers due to the demand on advanced features. Traditionally, the management of surgical treatment is generally manually operated and there is no consistent operating procedure for patients transferring among wards, surgery waiting rooms, operating rooms, and recovery rooms, resulting in panicky and urgent transferring work among departments and, thus, leading to delays and errors. In this paper, we propose a new framework using radio frequency identification (RFID technology for a mobilized surgical process monitoring system. Through the active tag, an application management system used before, during, and after the surgical processes has been proposed. The concept of signal level matrix, SLM, was proposed to accurately identify patients and dynamically track patients’ location. By updating patient’s information real-time, the preprocessing time needed for various tasks and incomplete transfers among departments can be reduced, the medical resources can be effectively used, unnecessary medical disputes can be reduced, and more comprehensive health care environment can be provided. The feasibility and effectiveness of our proposed system are demonstrated with a number of experimental results.

  12. Hospital Patient Room Design: The Issues Facing 23 Occupational Groups Who Work in Medical/Surgical Patient Rooms.

    Science.gov (United States)

    Lavender, Steven A; Sommerich, Carolyn M; Patterson, Emily S; Sanders, Elizabeth B-N; Evans, Kevin D; Park, Sanghyun; Umar, Radin Zaid Radin; Li, Jing

    2015-01-01

    The aim of this study was to learn from a wide range of hospital staff members about how the design of the patient room in which they work adversely affects their ergonomics or hinders their job performance. In addition to providing a healing space for patients, hospital patient rooms need to serve as functional workplaces for the people who provide clinical care, to clean, or to maintain room functions. Therefore, from a design perspective, it is important to understand the needs of all the users of hospital patient rooms with regard to room design. One hundred forty-seven people, representing 23 different occupational stakeholder groups, participated in either focus groups or interviews in which they were asked to identify room design issues that affect the performance of their work tasks. Key issues shared across multiple stakeholder groups included an inability to have eye contact with the patient when entering the room, inadequate space around the bed for the equipment used by stakeholders, the physical demands experienced as stakeholders move furnishings to accomplish their activities or access equipment, and a lack of available horizontal surfaces. Unique issues were also identified for a number of stakeholder groups. There are a number of issues that should be addressed in the next generation of hospital patient rooms, or when refurbishing existing facilities, so that all occupational stakeholder groups can work effectively, efficiently, and without undue physical stress. © The Author(s) 2015.

  13. Dose determination of Neutron contamination in radiothrapy rooms equiped with high energy linear accelerators

    International Nuclear Information System (INIS)

    Shweikani, R.; Anjak, O.

    2014-03-01

    Radiotherapy represents the most widely spread technique to control and treat cancer. To increase the treatment efficiency, high-energy linear accelerators are used. However, applying high energy photon beams leads to a non-negligible dose of neutrons contaminating therapeutic beams. A high-energy (23 MV) linear accelerator (Varian 21EX) was studied. The CR-39 nuclear track detectors (NTDs) were used to study the variation of fast neutron relative intensities around a linear accelerator high energy photon beam and to determined the its variation on the patient plane at 0, 50, 100, 150 and 200 cm from the center of the photon beam was. By increasing the distance from the center of the X-ray beam towards the periphery, the photoneutron dose equivalent decreased rapidly for the fields. Photoneutron intensity and distributions at isocenter level with the field sizes of 40*40 cm'2 at SSD=100cm around 23 MV photon beam using Nuclear Track Detectors were determined. The advantages of CR-39 NTD s over active detectors: 1- there is no pulse pileup problem. 2- no photon interference with neutron measurement. 3- no electronics are required. 4 - less prone to noise and interference. The photoneutron intensities were rapidly decreased as we move away from the isocenter of linear accelerators. As the use of simulation software MCNP match in the results we have obtained through direct measurements and the modeling results using the code MCNP (author).

  14. Shielding design of a treatment room for an accelerator-based epithermal neutron irradiation facility for BNCT

    International Nuclear Information System (INIS)

    Evans, J.F.; Blue, T.E.

    1996-01-01

    Protecting the facility personnel and the general public from radiation exposure is a primary safety concern of an accelerator-based epithermal neutron irradiation facility. This work makes an attempt at answering the questions open-quotes How much?close quotes and open-quotes What kind?close quotes of shielding will meet the occupational limits of such a facility. Shielding effectiveness is compared for ordinary and barytes concretes in combination with and without borated polyethylene. A calculational model was developed of a treatment room, patient open-quotes scatterer,close quotes and the epithermal neutron beam. The Monte Carlo code, MCNP, was used to compute the total effective dose equivalent rates at specific points of interest outside of the treatment room. A conservative occupational effective dose rate limit of 0.01 mSv h -1 was the guideline for this study. Conservative Monte Carlo calculations show that constructing the treatment room walls with 1.5 m of ordinary concrete, 1.2 m of barytes concrete, 1.0 m of ordinary concrete preceded by 10 cm of 5% boron-polyethylene, or 0.8 m of barytes concrete preceded by 10 cm of 5% boron-polyethylene will adequately protect facility personnel. 20 refs., 8 figs., 2 tabs

  15. A novel technique to optimise the length of a linear accelerator treatment room maze without compromising radiation protection.

    Science.gov (United States)

    Al-Affan, I A M; Evans, S C; Qutub, M; Hugtenburg, R P

    2018-03-01

    Simulations with the FLUktuierende KAskade (FLUKA) Monte Carlo code were used to establish the possibility of introducing lead to cover the existing concrete walls of a linear accelerator treatment room maze, in order to reduce the dose of the scattered photons at the maze entrance. In the present work, a pilot study performed at Singleton Hospital in Swansea was used to pioneer the use of lead sheets of various thicknesses to absorb scattered low energy photons in the maze. The dose reduction was considered to be due to the strong effect of the photoelectric interaction in lead resulting in attenuation of the back-scattered photons. Calculations using FLUKA with mono-energetic photons were used to represent the main components of the x-ray spectrum up to 10 MV. Mono-energetic photons were used to enable the study of the behaviour of each energy component from the associated interaction processes. The results showed that adding lead of 1 to 4 mm thickness to the walls and floor of the maze reduced the dose at the maze entrance by up to 80%. Subsequent scatter dose measurements performed at the maze entrance of an existing treatment room with lead sheet of 1.3 mm thickness added to the maze walls and floor supported the results from the simulations. The dose reduction at the maze entrance with the lead in place was up to 50%. The variation between simulation and measurement was attributed to the fact that insufficient lead was available to completely cover the maze walls and floor. This novel proposal of partly, or entirely, covering the maze walls with lead a few millimetres in thickness has implications for the design of linear accelerator treatment rooms since it has the potential to provide savings, in terms of space and costs, when an existing maze requires upgrading in an environment where space is limited and the maze length cannot be extended sufficiently to reduce the dose.

  16. Positron emission medical measurements with accelerated radioactive ion beams

    International Nuclear Information System (INIS)

    Llacer, J.

    1988-01-01

    This paper reviews in some detail the process by which a heavy ion accelerator can be used to inject positron emitting radioactive particles into a human body for a range of possible medical measurements. The process of radioactive beam generation and injection is described, followed by a study of the relationship between activity that can be injected versus dose to the patient as a function of which of the positron emitting ions is used. It is found that 6 C 10 and 10 Ne 19 are the two isotopes that appear more promising for injection into humans. The design considerations for a non-tomographic instrument to obtain images from beam injections are outlined and the results of 10 Ne 19 preliminary measurements with human phantoms and actual patients for the determination of end-of-range of cancer therapy ion beams is reported. Accuracies in the order of ±1 mm in the measurements of stopping point of a therapy beam with safe doses to the patient are reported. The paper concludes with a simple analysis of requirements to extend the technique to on-line verification of cancer treatment and to nuclear medicine research and diagnostics measurements. 17 refs.; 16 figs.; 3 tabs

  17. Environmental impact assessment methods of the radiation generated by the runing medical linear accelerator

    International Nuclear Information System (INIS)

    Yin haihua; Yao Zhigang

    2014-01-01

    This article describes the environmental impact assessment methods of the radiation generated by the runing. medical linear accelerator. The material and thickness of shielding wall and protective doors of the linear accelerator were already knew, therefore we can evaluate the radiation by the runing. medical linear accelerator whether or not in the normal range of national standard by calculating the annual effective radiation dose of the surrounding personnel suffered. (authors)

  18. Research on cw electron accelerators using room-temperature rf structures. Annual report

    International Nuclear Information System (INIS)

    1985-01-01

    Highlights reported include: measurement of the 100 keV chopped beam emittance, completion of installation of the entire 5 MeV injector linac system with all rf power and drive, extensive field mapping of one end magnet, completion of construction of the 12 MeV linac for the racetrack microtron (RTM), installation of most of the control system, and first acceleration of beam to 5 MeV. Plans for completion of the project are discussed. When the RTM is operating, it is expected to have many unique performance characteristics, including the cw nature of the beam, high current, easily variable energy over a wide range, excellent emittance, and small energy spread. Plans for future uses in the areas of nuclear physics, dosimetry research and standards, accelerator development, and free electron laser research are discussed. 19 refs

  19. An injector system of a NDZ-20 medical electron linear accelerator

    International Nuclear Information System (INIS)

    Wang Houwen; Lai Qiji; Zhu Yizhang; Yang Fangxin

    1987-01-01

    The structure and characteristic of an injector system of a NDZ-20 medical electron linear accelerator are described. A bombarded type of Pierce electron gun is used. There are pre-focusing coil, deflecting coil, steering coil and beam pulse lead cutting coil in drift tube region. They control electron beam efficiently for ARC, ADC and BLC of the accelerator. ARC and ADC can increase stability and reliability of the accelerator operation, and BLC improves energy spectrum of the back feed accelerator

  20. Determination of the neutron spectra in the treatment room of a linear accelerator for radiotherapy

    International Nuclear Information System (INIS)

    Vega C, H.R.; Barquero, R.; Mendez, R.; Iniguez, M.P.

    2003-01-01

    By means of a series of measures and Monte Carlo calculations the dosimetric characteristics of the photoneutrons have been determined that take place in volume to a linear accelerator of radiotherapy of 18 MV, LINAC, mark Siemens Mevatron model. The measures were carried out with thermoluminescent dosemeters TLD 600 and TLD 700 that were naked exposed and confined with cover of Cd and Sn, inside a sphere of paraffin and inside spheres Bonner. (Author)

  1. Monte Carlo simulation of medical linear accelerator using primo code

    International Nuclear Information System (INIS)

    Omer, Mohamed Osman Mohamed Elhasan

    2014-12-01

    The use of monte Carlo simulation has become very important in the medical field and especially in calculation in radiotherapy. Various Monte Carlo codes were developed simulating interactions of particles and photons with matter. One of these codes is PRIMO that performs simulation of radiation transport from the primary electron source of a linac to estimate the absorbed dose in a water phantom or computerized tomography (CT). PRIMO is based on Penelope Monte Carlo code. Measurements of 6 MV photon beam PDD and profile were done for Elekta precise linear accelerator at Radiation and Isotopes Center Khartoum using computerized Blue water phantom and CC13 Ionization Chamber. accept Software was used to control the phantom to measure and verify dose distribution. Elektalinac from the list of available linacs in PRIMO was tuned to model Elekta precise linear accelerator. Beam parameter of 6.0 MeV initial electron energy, 0.20 MeV FWHM, and 0.20 cm focal spot FWHM were used, and an error of 4% between calculated and measured curves was found. The buildup region Z max was 1.40 cm and homogenous profile in cross line and in line were acquired. A number of studies were done to verily the model usability one of them is the effect of the number of histories on accuracy of the simulation and the resulted profile for the same beam parameters. The effect was noticeable and inaccuracies in the profile were reduced by increasing the number of histories. Another study was the effect of Side-step errors on the calculated dose which was compared with the measured dose for the same setting.It was in range of 2% for 5 cm shift, but it was higher in the calculated dose because of the small difference between the tuned model and measured dose curves. Future developments include simulating asymmetrical fields, calculating the dose distribution in computerized tomographic (CT) volume, studying the effect of beam modifiers on beam profile for both electron and photon beams.(Author)

  2. Optimisation of structural shielding of accelerator control room for compliance with ALARA principle under Indian conditions

    International Nuclear Information System (INIS)

    Ahmad, Masood; Singh, Brijesh

    1999-01-01

    The case of a 20 MV x-ray accelerator has been considered in this paper for optimisation. An internationally recommended value of α = US$ 1000 per person-sievert has been assumed. Cost of concrete has been assumed as US$ 82.7/m 3 . It is seen that, extra shielding is needed to satisfy the ALARA principle. Further, the amount of requisite shielding increases with the degree of occupancy and, also, if the local construction materials or the labour are cheaper than considered in this paper. Accordingly 1.5 to 4.75 HVLs may be needed as extra shielding in different situations. Therefore, a site specific and installation specific optimisation of shielding is necessary

  3. The third person in the room: frequency, role, and influence of companions during primary care medical encounters.

    Science.gov (United States)

    Schilling, Lisa M; Scatena, Lisa; Steiner, John F; Albertson, Gail A; Lin, C T; Cyran, Lisa; Ware, Lindsay; Anderson, Robert J

    2002-08-01

    We wanted to characterize patient accompaniment to medical encounters and to explore the rationale and influence of the companion on the primary care medical encounter. This was a descriptive study. Academic general internal medicine physicians, patients, and patient companions participated. We measured the frequency of waiting and examination room companions, the reasons for accompaniment, the influence on the encounter, and the overall helpfulness of the companion as assessed by patients and companions. We also determined the physicianamprsquos assessment of the companionamprsquos influence, helpfulness, and behavior during the encounter. Companions were in the examination room for 16% of visits; 93% were family members. The rationales for waiting and examination room companions were to help with transportation, provide emotional support, and provide company. Examination room companions helped communicate concerns to the physician, remember the physicianamprsquos advice, make decisions, and communicate their own concerns to the physician. Patients believed that examination room companions influenced 75% of medical encounters, mainly by improving communication between physician and patient. Physicians agreed that examination room companions favorably influenced physician and patient understanding (60% and 46% of encounters, respectively). Patients indicated that waiting and examination room companions were very helpful for 71% and 83% of visits, respectively. Companions frequently accompany patients to their primary care medical encounters. They are often family members, and they assume important roles in enhancing patient and physician understanding.

  4. Ethical views, attitudes and reactions of Romanian medical students to the dissecting room.

    Science.gov (United States)

    Bob, M H; Popescu, Codruţa Alina; Armean, M S; Suciu, Soimita Mihaela; Buzoianu, Anca Dana

    2014-01-01

    Our objective was to evaluate the attitudes and views of first year medical students towards cadaver dissection in anatomy learning and discuss various findings in relation with ethical problems). The study was conducted at the "Iuliu Hat ieganu" University of Medicine and Pharmacy, during the academic year 2012-2013 at the end of the second semester. There were 121 first year medical students included. We developed a questionnaire to asses among other, the degree of fear, anxiety and stress in the dissection room, methods of coping, ethical aspects of dissection and hand it to the students. 34.7% of students experienced different levels of fear on exposure to the dissection room practical sessions. Many students experienced anxiety in reaction to dissection. In the first semester most students reported physical and behavioral reaction towards certain stimuli, with a decrease in the second semester. Recurring visual images of cadavers, reported by 57% of students in the first semester, dropped to 44.6% in the second semester. Students used most frequently the "rationalization and emotional detachment" as a coping method. Anatomists, most often the firsts who need to be aware of emotional and ethical issues, need to explain in detail the steps necessary for dissection and that dissection is performed with the respect of legislation, ethics and human rights.

  5. Determination of the exposure speed of radiation emitted by the linear accelerator, using the code MCNP5 to evaluate the radiotherapy room shields of ABC Hospital

    International Nuclear Information System (INIS)

    Corral B, J. R.

    2015-01-01

    Humans should avoid exposure to radiation, because the consequences are harmful to health. Although there are different emission sources of radiation, generated by medical devices they are usually of great interest, since people who attend hospitals are exposed in one way or another to ionizing radiation. Therefore, is important to conduct studies on radioactive levels that are generated in hospitals, as a result of the use of medical equipment. To determine levels of exposure speed of a radioactive facility there are different methods, including the radiation detector and computational method. This thesis uses the computational method. With the program MCNP5 was determined the speed of the radiation exposure in the radiotherapy room of Cancer Center of ABC Hospital in Mexico City. In the application of computational method, first the thicknesses of the shields were calculated, using variables as: 1) distance from the shield to the source; 2) desired weekly equivalent dose; 3) weekly total dose equivalent emitted by the equipment; 4) occupation and use factors. Once obtained thicknesses, we proceeded to model the bunker using the mentioned program. The program uses the Monte Carlo code to probabilistic ally determine the phenomena of interaction of radiation with the shield, which will be held during the X-ray emission from the linear accelerator. The results of computational analysis were compared with those obtained experimentally with the detection method, for which was required the use of a Geiger-Muller counter and the linear accelerator was programmed with an energy of 19 MV with 500 units monitor positioning the detector in the corresponding boundary. (Author)

  6. Technical Note: A proposal of air ventilation system design criteria for a clinical room in a heavy-ion medical facility.

    Science.gov (United States)

    Kum, Oyeon

    2018-04-16

    An optimized air ventilation system design for a treatment room in Heavy-ion Medical Facility is an important issue in the aspects of nuclear safety because the activated air produced in a treatment room can directly affect the medical staff and the general public in the radiation-free area. Optimized design criteria of air ventilation system for a clinical room in 430 MeV/u carbon ion beam medical accelerator facility was performed by using a combination of MCNPX2.7.0 and CINDER'90 codes. Effective dose rate and its accumulated effective dose by inhalation and residual gamma were calculated for a normal treatment scenario (2 min irradiation for one fraction) as a function of decay time. Natural doses around the site were measured before construction and used as reference data. With no air ventilation system, the maximum effective dose rate was about 3 μSv/h (total dose of 90 mSv/y) and minimum 0.2 μSv/h (total dose of 6 mSv/y), which are over the legal limits for medical staff and for the general public. Although inhalation dose contribution was relatively small, it was considered seriously because of its long-lasting effects in the body. The integrated dose per year was 1.8 mSv/y in the radiation-free area with the 20-min rate of air ventilation system. An optimal air ventilation rate of 20 min is proposed for a clinical room, which also agrees with the best mechanical design value. © 2018 American Association of Physicists in Medicine.

  7. High-performance control system for a heavy-ion medical accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lancaster, H.D.; Magyary, S.B.; Sah, R.C.

    1983-03-01

    A high performance control system is being designed as part of a heavy ion medical accelerator. The accelerator will be a synchrotron dedicated to clinical and other biomedical uses of heavy ions, and it will deliver fully stripped ions at energies up to 800 MeV/nucleon. A key element in the design of an accelerator which will operate in a hospital environment is to provide a high performance control system. This control system will provide accelerator modeling to facilitate changes in operating mode, provide automatic beam tuning to simplify accelerator operations, and provide diagnostics to enhance reliability. The control system being designed utilizes many microcomputers operating in parallel to collect and transmit data; complex numerical computations are performed by a powerful minicomputer. In order to provide the maximum operational flexibility, the Medical Accelerator control system will be capable of dealing with pulse-to-pulse changes in beam energy and ion species.

  8. High-performance control system for a heavy-ion medical accelerator

    International Nuclear Information System (INIS)

    Lancaster, H.D.; Magyary, S.B.; Sah, R.C.

    1983-03-01

    A high performance control system is being designed as part of a heavy ion medical accelerator. The accelerator will be a synchrotron dedicated to clinical and other biomedical uses of heavy ions, and it will deliver fully stripped ions at energies up to 800 MeV/nucleon. A key element in the design of an accelerator which will operate in a hospital environment is to provide a high performance control system. This control system will provide accelerator modeling to facilitate changes in operating mode, provide automatic beam tuning to simplify accelerator operations, and provide diagnostics to enhance reliability. The control system being designed utilizes many microcomputers operating in parallel to collect and transmit data; complex numerical computations are performed by a powerful minicomputer. In order to provide the maximum operational flexibility, the Medical Accelerator control system will be capable of dealing with pulse-to-pulse changes in beam energy and ion species

  9. Evaluating Operating Room Turnaround Times and Cancellations at Dwight D. Eisenhower Army Medical Center

    National Research Council Canada - National Science Library

    Amsink, William L

    2005-01-01

    .... This study describes the inefficient use of the current operating room management software system, and identifies strategies to improve operating room efficiency by analyzing the most common causes...

  10. FFAGs: Front-end for neutrino factories and medical accelerators

    Science.gov (United States)

    Mori, Yoshiharu

    The idea of Fixed Field Alternating Gradient (FFAG) accelerator was originated by different people and groups in the early 1950s. It was independently introduced by Ohkawa [Ohkawa (1953)], Symon et al. [Symon et al. (1956)], and Kolomensky [Kolomensky and Lebedev (1966)] when the strong Alternate Gradient (AG) focusing and the phase stability schemes were applied to particle acceleration. The first FFAG electron model was developed in the MURA accelerator project led by Kerst and Cole in the late 1950s. Since then, they have fabricated several electron models in the early 1960s [Symon et al. (1956)]. However, the studies did not lead to a single practical FFAG accelerator for the following 50 years. Because of the difficulties of treating non-linear magnetic field and RF acceleration for non-relativistic particles, the proton FFAG, especially, was not accomplished until recently. In 2000, the FFAG concept was revived with the world's first proton FFAG (POP) which was developed at KEK [Aiba (2000); Mori (1999)]. Since then, in many places [Berg (2004); Johnstone et al. (2004); Mori (2011); Ruggiero (2004); Trbojevic (2004)], FFAGs have been developed and constructed...

  11. Some issues that easily to be overlooked during the environmental impact assessment of medical electrical accelerators

    International Nuclear Information System (INIS)

    Fu Jie; Zhou Qifu; Chen Dongliang

    2011-01-01

    This paper mainly introduces the contents of shielding design in the No. 151 report of NCRP published in 2005, discusses some issues that easily to be overlooked during the environmental impact assessment of medical electrical accelerators in China. Some references will be provided in the medical electrical accelerators' shielding design and assessment to achieved the purpose of scientific, reasonable, feasible and economical radiation shielding protection. (authors)

  12. Ambient neutron dose equivalent outside concrete vault rooms for 15 and 18 MV radiotherapy accelerators

    International Nuclear Information System (INIS)

    Martinez-ovalle, S. A.; Barquero, R.; Gomez-ros, J. M.; Lallena, A. M.

    2012-01-01

    In this work, the ambient dose equivalent, H*(10), due to neutrons outside three bunkers that house a 15- and a 18-MV Varian Clinac 2100C/D and a 15-MV Elekta Inor clinical linacs, has been calculated. The Monte Carlo code MCNPX (v. 2.5) has been used to simulate the neutron production and transport. The complete geometries including linacs and full installations have been built up according to the specifications of the manufacturers and the planes provided by the corresponding medical physical services of the hospitals where the three linacs operate. Two of these installations, those lodging the Varian linacs, have an entrance door to the bunker while the other one does not, although it has a maze with two bends. Various treatment orientations were simulated in order to establish plausible annual equivalent doses. Specifically anterior-posterior, posterior-anterior, left lateral, right lateral orientations and an additional one with the gantry rotated 30 deg. have been studied. Significant dose rates have been found only behind the walls and the door of the bunker, near the entrance and the console, with a maximum of 12 μSv h -1 . Dose rates per year have been calculated assuming a conservative workload for the three facilities. The higher dose rates in the corresponding control areas were 799 μSv y -1 , in the case of the facility which operates the 15-MV Clinac, 159 μSv y -1 , for that with the 15-MV Elekta, and 21 μSv y -1 for the facility housing the 18-MV Varian. A comparison with measurements performed in similar installations has been carried out and a reasonable agreement has been found. The results obtained indicate that the neutron contamination does not increase the doses above the legal limits and does not produce a significant enhancement of the dose equivalent calculated. When doses are below the detection limits provided by the measuring devices available today, MCNPX simulation provides an useful method to evaluate neutron dose equivalents

  13. Evaluating the attendance of medical staff and room occupancy during palliative radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Adamietz, Irenaeus A. [University of Bochum, Department of Radiation Oncology, Bochum (Germany); Marienhospital Herne, Department of Radiotherapy and Radiation Oncology, Herne (Germany); Micke, Oliver [Franziskus-Hospital, Department of Radiation Oncology, Bielefeld (Germany); Popp, Wolfgang [Prime Networks AG, Basel (Switzerland); Sack, Horst [DEGRO, Berlin (Germany)

    2014-09-15

    Attendance of staff and use of resources during treatment have an impact on costs. For palliative radiotherapy, no reliable data are available on the subject. Therefore, the measurement of selected variables (staff absorbance and room occupancy) based on daily palliative irradiation was the aim of our prospective study. The analysis is part of a larger study conducted by the German Society of Radiation Oncology (DEGRO). A total of 172 palliative radiation treatments were followed up prospectively between October 2009 and March 2010. The study was performed at two experienced radiotherapy departments (Herne and Bielefeld) and evaluated the attendance of medical personnel and room occupancy related to the selected steps of the treatment procedure: treatment planning and daily application of radiation dose. Computed tomography for treatment planning engaged the unit for 19 min (range: 17-22 min). The localization of target volume required on average 28 min of a technician's working time. The mean attendance of the entire staff (radiation oncologist, physicist, technician) for treatment planning was 159 min, while the total room occupancy was 140 min. Depending on the type of treatment, the overall duration of a radiotherapy session varied on average between 8 and 18 min. The staff was absorbed by the first treatment session (including portal imaging) for 8-27 min. Mean room occupancy was 18 min (range: 6-65 min). The longest medical staff attendance was observed during an initial irradiation session (mean: 11 min). Radiotherapy sessions with weekly performed field verifications occupied the rooms slightly longer (mean: 10 min, range: 4-25 min) than daily radiotherapy sessions (mean: 9 min, range: 3-29 min). We observed that the patients' symptoms, their condition, and their social environment confounded the time schedule. Target localization, treatment planning, and performance of palliative radiotherapy absorb resources to an extent comparable to

  14. Accelerator-driven Medical Sterilization to Replace Co-60 Sources

    Energy Technology Data Exchange (ETDEWEB)

    Kroc, Thomas K. [Fermilab; Thangaraj, Jayakar C.T. [Fermilab; Penning, Richard T. [Fermilab; Kephart, Robert D. [Fermilab

    2017-08-11

    This report documents the results of a study prepared at the request of the Office of Radiological Security of the National Nuclear Security Administration (NNSA), as part of the Domestic Protect and Reduce mission by the Illinois Accelerator Research Center (IARC) of Fermi National Accelerator Laboratory. The study included a literature survey of over 80 relevant documents and articles including industry standards, regulatory documents, technical papers, a court case, previous task force reports and industry white papers. The team also conducted interviews or had conversations with over 40 individuals representing over a dozen organizations over the course of its 10-month program. This report summarizes our findings, addresses the specific questions posed to us by NNSA, and concludes with a list of actionable recommendations.

  15. Medical writing on an accelerated path in India

    Science.gov (United States)

    Shirke, Sarika

    2015-01-01

    The medical writing industry is on an upwards growth path in India. This is probably driven by an increasing urgency to have high-quality documents authored to support timely drug approvals, complemented by the realization that the competencies required are available in emerging geographies such as India. This article reviews the business landscape and the opportunities and challenges associated with outsourcing medical writing work India. It also analyzes the core competencies that a medical writer should possess and enlists various associations supporting learning in this domain. PMID:26229746

  16. Medical writing on an accelerated path in India.

    Science.gov (United States)

    Shirke, Sarika

    2015-01-01

    The medical writing industry is on an upwards growth path in India. This is probably driven by an increasing urgency to have high-quality documents authored to support timely drug approvals, complemented by the realization that the competencies required are available in emerging geographies such as India. This article reviews the business landscape and the opportunities and challenges associated with outsourcing medical writing work India. It also analyzes the core competencies that a medical writer should possess and enlists various associations supporting learning in this domain.

  17. Calibration and application of medical particle accelerators to space radiation experiments

    International Nuclear Information System (INIS)

    Ryu, Kwangsun; Park, Miyoung; Chae, Jangsoo; Yoon, Sangpil; Shin, Dongho

    2012-01-01

    In this paper, we introduce radioisotope facilities and medical particle accelerators that can be applied to space radiation experiments and the experimental conditions required by the space radiation experiments. Space radiation experiments on the ground are critical in determining the lifetimes of satellites and in choosing or preparing the appropriate electrical parts to assure the designated mission lifetime. Before the completion of building the 100-MeV proton linear accelerator in Gyeongju, or even after the completion, the currently existing proton accelerators for medical purposes could suggest an alternative plan. We have performed experiments to calibrate medical proton beam accelerators to investigate whether the beam conditions are suitable for applications to space radiation experiments. Based on the calibration results, we propose reference beam operation conditions for space radiation experiments.

  18. A proton medical accelerator by the SBIR route — an example of technology transfer

    Science.gov (United States)

    Martin, R. L.

    1989-04-01

    Medical facilities for radiation treatment of cancer with protons have been established in many laboratories throughout the world. Essentially all of these have been designed as physics facilities, however, because of the requirement for protons up to 250 MeV. Most of the experience in this branch of accelerator technology lies in the national laboratories and a few large universities. A major issue is the transfer of this technology to the commercial sector to provide hospitals with simple, reliable and relatively inexpensive accelerators for this application. The author has chosen the SBIR route to accomplish this goal. ACCTEK Associates has received grants from the National Cancer Institute for development of the medical accelerator and beam delivery systems. Considerable encouragement and help has been received from Argonne National Laboratory and the Department of Energy. The experiences to date and the pros and cons on this approach to commercializing medical accelerators are described.

  19. A proton medical accelerator by the SBIR route - an example of technology transfer

    International Nuclear Information System (INIS)

    Martin, R.L.

    1989-01-01

    Medical facilities for radiation treatment of cancer with protons have been established in many laboratories throughout the world. Essentially all of these have been designed as physics facilities, however, because of the requirement for protons up to 250 MeV. Most of the experience on this branch of accelerator technology lies in the national laboratories and a few large universities. A major issue is the transfer of this technology to the commercial sector to provide hospitals with simple, reliable, and relatively inexpensive accelerators for this application. The author has chosen the SBIR route to accomplish this goal. ACCTEK Associates has received grants from the National Cancer Institute for development of the medical accelerator and beam delivery systems. Considerable encouragement and help has been received from Argonne National Laboratory and the Department of Energy. The experiences to date and the pros and cons on this approach to commercializing medical accelerators are described. (orig.)

  20. A proton medical accelerator by the SBIR route: An example of technology transfer

    International Nuclear Information System (INIS)

    Martin, R.L.

    1988-01-01

    Medical facilities for radiation treatment of cancer with protons have been established in many laboratories throughout the world. Essentially all of these have been designed as physics facilities, however, because of the requirement for protons up to 250 MeV. Most of the experience in this branch of accelerator technology lies in the national laboratories and a few large universities. A major issue is the transfer of this technology to the commercial sector to provide hospitals with simple, reliable, and relatively inexpensive accelerators for this application. The author has chosen the SBIR route to accomplish this goal. ACCTEK Associates have received grants from the National Cancer Institute for development of the medical accelerator and beam delivery systems. Considerable encouragement and help has been received from Argonne National Laboratory and the Department of Energy. The experiences to date and the pros and cons on this approach to commercializing medical accelerators are described. 4 refs., 1 fig

  1. Accelerating medical education: a survey of deans and program directors

    Directory of Open Access Journals (Sweden)

    Joan Cangiarella

    2016-06-01

    Full Text Available Background: A handful of medical schools in the U.S. are awarding medical degrees after three years. While the number of three-year pathway programs is slowly increasing there is little data on the opinions of medical education leaders on the need for shortening training. Purpose: To survey deans and program directors (PDs to understand the current status of 3-year medical degree programs and to elicit perceptions of the need for shortening medical school and the benefits and liabilities of 3-year pathway programs (3YPP. Methods: Online surveys were emailed to the academic deans of all U.S. medical schools and to a convenience sample of residency and fellowship PDs. Frequency distributions are reported for key survey items and content analysis was used to describe open-ended responses. Results: Of the respondents, 7% have a 3YPP, 4% were developing one, and 35% were considering development. In 2014, 47% of educational deans and 32% of PDs agreed that there may be a need to shorten medical school. From a list of benefits, both deans and PDs agreed that the greatest benefit to a 3YPP was debt reduction (68%. PDs and deans felt reduced readiness for independence, reduced exposure to complementary curricula regarding safety and quality improvement, premature commitment to a specialty, and burnout were all potential liabilities. From a list of concerns, PDs were concerned about depth of clinical exposure, direct patient care experience, ability to assume increased responsibility, level of maturity, and certainty regarding career choice. Conclusions: Over one-third of medical schools are considering the development of a 3YPP. While there may be benefits for a select group of students, concerns regarding maturity, depth of clinical exposure, and competency must be addressed for these programs to be well received.

  2. [Management of an elderly patient in the emergency room at the end of life : A medical ethics challenge].

    Science.gov (United States)

    Michels, G; Nies, R; Ortmann, S; Pfister, R; Salomon, F

    2018-04-01

    A 94-year-old patient with cardiogenic shock due to myocardial infarction was admitted via the emergency room. A coronary angiography and intensive care were requested. The need for care due to dementia was known. After case discussion in the interdisciplinary and multiprofessional treatment team, the decision for a palliative care concept in the form of symptom control was made in the emergency room, taking into account the patient's medical history, the current situation, and the presumed patient consent. The integration of medical ethics aspects and palliative medicine into "geriatric emergency medicine" will present a challenge in the future.

  3. Determination Of The QUART Ion Chamber Stability By Using Medical Linear Accelerator

    International Nuclear Information System (INIS)

    Nasukha.

    1990-01-01

    The Quality Assurance Radiation Therapy (QUART) ion chamber was designed for quality assurance measurements of the medical linear accelerator at the Department of Radiation Oncology, Westmead Hospital in Sydney-Australia. The ion chamber has been calibrated by using the 6 MV medical linear accelerator against the farmer dosimeter. The Medical Physics Department Protocol, Westmead Hospital, Sydney (Australia) was used to check the stability of QUART ion chamber by determination of calibration factor for a period of time. It was found that the stability of the seven chambers were less than 2% for more than 125 days. (author). 4 refs, 7 figs

  4. Evaluation of the Induced Activity in Air by the External Proton Beam in the Target Room of the Proton Accelerator Facility of Proton Engineering Frontier Project

    International Nuclear Information System (INIS)

    Lee, Cheol Woo; Lee, Young Ouk; Cho, Young Sik; Ahn, So Hyun

    2007-01-01

    One of the radiological concerns is the worker's exposure level and the concentration of the radionuclides in the air after shutdown, for the safety analysis on the proton accelerator facility. Although, the primary radiation source is the protons accelerated up to design value, all of the radio-nuclide is produced from the secondary neutron and photon induced reaction in air. Because, the protons don't penetrate the acceleration equipment like the DTL tank wall or BTL wall, secondary neutrons or photons are only in the air in the accelerator tunnel building because of the short range of the proton in the materials. But, for the case of the target rooms, external proton beams are occasionally used in the various experiments. When these external proton beams travel through air from the end of the beam transport line to the target, they interact directly with air and produce activation products from the proton induced reaction. The external proton beam will be used in the target rooms in the accelerator facility of the Proton Accelerator Frontier Project (PEFP). In this study, interaction characteristics of the external proton beam with air and induced activity in air from the direct interaction of the proton beam were evaluated

  5. Induced radioactivity in air and water at medical accelerators

    International Nuclear Information System (INIS)

    Masumoto, K.; Takahashi, K.; Nakamura, H.; Toyoda, A.; Iijima, K.; Kosako, K.; Oishi, K.; Nobuhara, F.

    2013-01-01

    Activation of air and water has been evaluated at the 10 and 15 MeV linear electron accelerator facilities. At 15 MeV irradiation, the activity of 10-min-half-life 13 N was observed in the case of the air in the glove box. Air and water samples were also bombarded by 250 MeV protons and 400 MeV/u carbon, and the irradiation dose was 10 Gy at the isocenter. Upon the ion-chamber monitoring of the air sampled from the glove box, 15 O, 13 N, and 11 C activities were mainly observed. At the end of proton and carbon irradiation, the activity of the water was found to be about 10 kBq·cm -3 and several kBq·cm -3 , respectively. From the decay analysis of the induced activity in water, 15 O, 13 N, and 11 C were detected. (author)

  6. Production of 123I for medical use with small accelerators

    International Nuclear Information System (INIS)

    Beyer, G.J.; Pimentel, G.; Solin, O.; Heselius, S.J.; Taka, T.

    1988-01-01

    The possibilities of 123 I production with small accelerators are discussed. Among the possible nuclear reactions the 122 Te(d,n) 123 I and the 123 Te(p,n) 123 I reaction are of particular interest for those institutions, who do not run a cyclotron with particle energies for protons above 18-20 MeV. The use of TeO 2 as target material is advantaged over Te. The 123 I preparations contain resonable amounts of 130 I and 124 I. The most 'dangerous' impurity is 130 I due to its high energy gamma radiation. Nevertheless, high quality imagings may be obtained using medium or high energy collimators loosing some of the advantages of 123 I. The proposed approach is the only way to make 123 I available for a number of institutions or countries running small cyclotrons and for which commercial 123 I is difficult or impossible to obtain for economical or geographical reasons. (author)

  7. Intensity possibilities for the Loma Linda Medical Accelerator

    International Nuclear Information System (INIS)

    Young, P.E.; Morton, P.L.

    1991-01-01

    Based on questions and concerns over the possible intensity limitations of the Loma Linda Medical Synchrotron, a detailed study was conducted in order to determine the possible intensity limitations in the synchrotron as presently configured and what could be done in future machines in order to achieve better intensity performance. The losses in the operating machine were investigated as well as the possible space charge and coherent collective effects limits

  8. Medical applications of accelerators at Tata Memorial Centre

    International Nuclear Information System (INIS)

    Dinshaw, K.A.

    2003-01-01

    The Tata Memorial Centre constitutes the national comprehensive cancer centre for the prevention, diagnosis, treatment and research on cancer. It is well equipped with sophisticated state-of-the-art equipment capable of delivering External Beam Radiotherapy (Ebert) and Brachytherapy. Nearly 400 patients receive Ebert daily at the institute from a team of highly skilled and dedicated radiation oncologists, medical physicists and technologists, making it one of the busiest centres in the country

  9. Telementoring systems in the operating room: a new approach in medical training

    Directory of Open Access Journals (Sweden)

    Juan P. Wachs

    2013-12-01

    Full Text Available This paper discusses the challenges and innovations related to the use of telementoring systems in the operating room. Most of the systems presented leverage on three types of interaction channels: audio, visual and physical. The audio channel enables the mentor to verbally instruct the trainee, and allows the trainee to ask questions. The visual channel is used to deliver annotations, alerts and other messages graphically to the trainee during the surgery. These visual representations are often displayed through a telestrator. The physical channel has been used in laparoscopic procedures by partially controlling the laparoscope through force-feedback. While in face to face instruction, the mentor produces gestures to convey certain aspects of the surgical instruction, there is not equivalent of this form of physical interaction between the mentor and trainee in open surgical procedures in telementoring systems. Even that the trend is to perform more minimally invasive surgery (MIS, trauma surgeries are still necessary, where initial resuscitation and stabilization of the patient in a timely manner is crucial. This paper presents a preliminary study conducted at the Indiana University Medical School and Purdue University, where initial lexicons of surgical instructive gestures (SIGs were determined through systematic observation when mentor and trainee operate together. The paper concludes with potential ways to convey gestural information through surgical robots.

  10. Telementoring systems in the operating room: a new approach in medical training.

    Science.gov (United States)

    Wachs, Juan P; Gomez, Gerardo

    2013-01-01

    This paper discusses the challenges and innovations related to the use of telementoring systems in the operating room. Most of the systems presented leverage on three types of interaction channels: audio, visual and physical. The audio channel enables the mentor to verbally instruct the trainee, and allows the trainee to ask questions. The visual channel is used to deliver annotations, alerts and other messages graphically to the trainee during the surgery. These visual representations are often displayed through a telestrator. The physical channel has been used in laparoscopic procedures by partially controlling the laparoscope through force-feedback. While in face to face instruction, the mentor produces gestures to convey certain aspects of the surgical instruction, there is not equivalent of this form of physical interaction between the mentor and trainee in open surgical procedures in telementoring systems. Even that the trend is to perform more minimally invasive surgery (MIS), trauma surgeries are still necessary, where initial resuscitation and stabilization of the patient in a timely manner is crucial. This paper presents a preliminary study conducted at the Indiana University Medical School and Purdue University, where initial lexicons of surgical instructive gestures (SIGs) were determined through systematic observation when mentor and trainee operate together. The paper concludes with potential ways to convey gestural information through surgical robots.

  11. [Intelligent operating room suite : From passive medical devices to the self-thinking cognitive surgical assistant].

    Science.gov (United States)

    Kenngott, H G; Wagner, M; Preukschas, A A; Müller-Stich, B P

    2016-12-01

    Modern operating room (OR) suites are mostly digitally connected but until now the primary focus was on the presentation, transfer and distribution of images. Device information and processes within the operating theaters are barely considered. Cognitive assistance systems have triggered a fundamental rethinking in the automotive industry as well as in logistics. In principle, tasks in the OR, some of which are highly repetitive, also have great potential to be supported by automated cognitive assistance via a self-thinking system. This includes the coordination of the entire workflow in the perioperative process in both the operating theater and the whole hospital. With corresponding data from hospital information systems, medical devices and appropriate models of the surgical process, intelligent systems could optimize the workflow in the operating theater in the near future and support the surgeon. Preliminary results on the use of device information and automatically controlled OR suites are already available. Such systems include, for example the guidance of laparoscopic camera systems. Nevertheless, cognitive assistance systems that make use of knowledge about patients, processes and other pieces of information to improve surgical treatment are not yet available in the clinical routine but are urgently needed in order to automatically assist the surgeon in situation-related activities and thus substantially improve patient care.

  12. Remanent radiation fields around medical linear accelerators due to the induced radionuclides

    International Nuclear Information System (INIS)

    Sabol, J.; Khalifa, O.; Berka, Z.; Stankus, P.; Frencl, L.

    1998-01-01

    Radiation fields around two linear accelerators, Saturn 43 and a Saturn 2 Plus, installed at radiotherapy department is Prague, were measured and interpreted. The measurements included the determination of the dose equivalent rate resulting from photons emitted by induced radionuclides produced in reactions of high-energy photons with certain elements present in air and accelerator components as well as in the shielding and building materials in the treatment rooms, which are irradiated by high-energy X-rays, and due to radionuclides formed by capture of photoneutrons. While scattered photons and photoneutrons are only present during the accelerator operation, residual radioactivity creates a remanent radiation field persisting for some time after the instrument shutdown. The activity induced in the accessories is also an important source of exposure. (P.A.)

  13. Correlated histogram representation of Monte Carlo derived medical accelerator photon-output phase space

    Science.gov (United States)

    Schach Von Wittenau, Alexis E.

    2003-01-01

    A method is provided to represent the calculated phase space of photons emanating from medical accelerators used in photon teletherapy. The method reproduces the energy distributions and trajectories of the photons originating in the bremsstrahlung target and of photons scattered by components within the accelerator head. The method reproduces the energy and directional information from sources up to several centimeters in radial extent, so it is expected to generalize well to accelerators made by different manufacturers. The method is computationally both fast and efficient overall sampling efficiency of 80% or higher for most field sizes. The computational cost is independent of the number of beams used in the treatment plan.

  14. High-quality laser-accelerated ion beams for medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Harman, Zoltan; Keitel, Christoph H. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Salamin, Yousef I. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); American University of Sharjah (United Arab Emirates)

    2009-07-01

    Cancer radiation therapy requires accelerated ion beams of high energy sharpness and a narrow spatial profile. As shown recently, linearly and radially polarized, tightly focused and thus extremely strong laser beams should permit the direct acceleration of light atomic nuclei up to energies that may offer the potentiality for medical applications. Radially polarized beams have better emittance than their linearly polarized counterparts. We put forward the direct laser acceleration of ions, once the refocusing of ion beams by external fields is solved or radially polarized laser pulses of sufficient power can be generated.

  15. Injection septum magnets for the Loma Linda medical accelerator

    International Nuclear Information System (INIS)

    Satti, J.A.

    1987-01-01

    The injection beamline runs over the last magnet before a long straight section and is then displaced downward 55.88 cm to the accelerator beamline. The displacement is magnetic and the final deflection onto the synchrotron orbit is by an electric kicker. The first component, the reverse septum magnet, bends the injection beam 25/degree/ downward. This is followed by the injection septum (20/degree/ bend upward) and the final injection kicker (5/degree/ bend upward). The septum magnets produce a peak field of 3.4 K gauss at a current of 28,000 amperes within a 0.1 msec long pulse. The electric kicker produces a field of 7.3 KV/cm with a pulse length of 0.0011 msec. The septum magnets are similar to each other in construction with a bending radium of 72.7 cm. The curvature is required to increase the effective aperture. Each magnet has a single-turn copper coil bonded to a stainless steel plate for reinforcement. This eliminates insulating material, which could be subject to radiation damage, at the septum. The stainless steel plate is welded to the magnet laminations. The current is confined to the septum by the insulation between the laminations, which are a standard core material. The total septum thickness with shield is 1.227 cm. Pulsing the magnet eliminates the need for water cooling. 2 refs., 4 figs

  16. Field size dependent mapping of medical linear accelerator radiation leakage

    International Nuclear Information System (INIS)

    Vu Bezin, Jérémi; De Vathaire, Florent; Diallo, Ibrahima; Veres, Attila; Lefkopoulos, Dimitri; Chavaudra, Jean; Deutsch, Eric

    2015-01-01

    The purpose of this study was to investigate the suitability of a graphics library based model for the assessment of linear accelerator radiation leakage. Transmission through the shielding elements was evaluated using the build-up factor corrected exponential attenuation law and the contribution from the electron guide was estimated using the approximation of a linear isotropic radioactive source. Model parameters were estimated by a fitting series of thermoluminescent dosimeter leakage measurements, achieved up to 100 cm from the beam central axis along three directions. The distribution of leakage data at the patient plane reflected the architecture of the shielding elements. Thus, the maximum leakage dose was found under the collimator when only one jaw shielded the primary beam and was about 0.08% of the dose at isocentre. Overall, we observe that the main contributor to leakage dose according to our model was the electron beam guide. Concerning the discrepancies between the measurements used to calibrate the model and the calculations from the model, the average difference was about 7%. Finally, graphics library modelling is a readily and suitable way to estimate leakage dose distribution on a personal computer. Such data could be useful for dosimetric evaluations in late effect studies. (paper)

  17. Evaluation of the photon monitor backscatter in medical electron accelerators

    International Nuclear Information System (INIS)

    Zrenner, M.; Krieger, H.

    1999-01-01

    Background: Modern linear accelerators permit the use of irregular fields due to their flexible collimator systems with separately movable jaws or multileaf collimators. When using such irregular fields in the clinical practice output factors have to be corrected for enhanced backscatter to the dose monitor as compared with the conventional block shieldings. Methods: A method is presented to detect the monitor backscatter contributions to the output factor for irregular field settings. Results: The monitor backscatter factors have been measured using a telescopic device for 2 different treatment head geometries (Varian Clinac 2100C/D, General Electric Saturne 15) and for 3 photon radiation qualities (nominal energies X6, X18, X12). A method is introduced to calculate the monitor backscatter for arbitrary irregular treatment fields from the experimental data for square or rectangular fields. Conclusions: Besides the corrections for changes in phantom scatter and changes in the aperture, corrections for monitor backscatter have to be taken into account in many clinical cases. They can contribute up to more than 10% compared with the monitor values for free regular fields. (orig.) [de

  18. Development of ECR ion source for the HIMAC medical accelerator

    International Nuclear Information System (INIS)

    Kitagawa, A.; Yamada, S.; Sekiguchi, M.

    1992-01-01

    The development of the ECR ion source for the HIMAC injector is reported. The HIMAC facility has two types of the ion source, one is the PIG ion source and the other is the ECR ion source. The ECR ion source is especially expected long lifetime, easy operation, and easy maintenance for the medical use. Now, the system of the ion source is under construction. However, the tests of fundamental performances have been started. In the present tests, the output electrical currents of Ions are 1300 eμA of He 1+ , 210 eμA of Ne 3+ , and 100 eμA of Ar 6+ . And the good stability of the extracted beam is acquired. These performances satisfied the requirements for the radiotherapy. (author)

  19. External radiotherapy. Particle accelerator - Radiation protection: medical sheet ED 4246

    International Nuclear Information System (INIS)

    2007-06-01

    After having indicated the required authorizations for the use of external radiotherapy installations, this document presents the various aspects and measures related to radiation protection of workers when performing such treatments. It presents the concerned personnel, describes the operational process, indicates the associated hazards and the risk related to ionizing radiation, and describes how the risk is to be assessed and how exposure levels are to be determined (elements of risk assessment, delimitation of controlled and monitored areas, personnel classification, and choice of the dose monitoring method). It describes the various components of a risk management strategy (risk reduction, technical measures regarding the installation and the personnel, training and information, prevention and medical monitoring). It briefly presents how risk management is to be assessed, and mentions other related risks

  20. Technical Note: On maximizing Cherenkov emissions from medical linear accelerators.

    Science.gov (United States)

    Shrock, Zachary; Yoon, Suk W; Gunasingha, Rathnayaka; Oldham, Mark; Adamson, Justus

    2018-04-19

    Cherenkov light during MV radiotherapy has recently found imaging and therapeutic applications but is challenged by relatively low fluence. Our purpose is to investigate the feasibility of increasing Cherenkov light production during MV radiotherapy by increasing photon energy and applying specialized beam-hardening filtration. GAMOS 5.0.0, a GEANT4-based framework for Monte Carlo simulations, was used to model standard clinical linear accelerator primary photon beams. The photon source was incident upon a 17.8 cm 3 cubic water phantom with a 94 cm source to surface distance. Dose and Cherenkov production was determined at depths of 3-9 cm. Filtration was simulated 15 cm below the photon beam source. Filter materials included aluminum, iron, and copper with thicknesses of 2-20 cm. Histories used depended on the level of attenuation from the filter, ranging from 100 million to 2 billion. Comparing average dose per history also allowed for evaluation of dose-rate reduction for different filters. Overall, increasing photon beam energy is more effective at improving Cherenkov production per unit dose than is filtration, with a standard 18 MV beam yielding 3.3-4.0× more photons than 6 MV. Introducing an aluminum filter into an unfiltered 2400 cGy/min 10 MV beam increases the Cherenkov production by 1.6-1.7×, while maintaining a clinical dose rate of 300 cGy/min, compared to increases of ~1.5× for iron and copper. Aluminum was also more effective than the standard flattening filter, with the increase over the unfiltered beam being 1.4-1.5× (maintaining 600 cGy/min dose rate) vs 1.3-1.4× for the standard flattening filter. Applying a 10 cm aluminum filter to a standard 18 MV, photon beam increased the Cherenkov production per unit dose to 3.9-4.3× beyond that of 6 MV (vs 3.3-4.0× for 18 MV with no aluminum filter). Through a combination of increasing photon energy and applying specialized beam-hardening filtration, the amount of Cherenkov photons per

  1. Mapping Iterative Medical Imaging Algorithm on Cell Accelerator

    Directory of Open Access Journals (Sweden)

    Meilian Xu

    2011-01-01

    architectures that exploit data parallel applications, medical imaging algorithms such as OS-SART can be studied to produce increased performance. In this paper, we map OS-SART on cell broadband engine (Cell BE. We effectively use the architectural features of Cell BE to provide an efficient mapping. The Cell BE consists of one powerPC processor element (PPE and eight SIMD coprocessors known as synergetic processor elements (SPEs. The limited memory storage on each of the SPEs makes the mapping challenging. Therefore, we present optimization techniques to efficiently map the algorithm on the Cell BE for improved performance over CPU version. We compare the performance of our proposed algorithm on Cell BE to that of Sun Fire ×4600, a shared memory machine. The Cell BE is five times faster than AMD Opteron dual-core processor. The speedup of the algorithm on Cell BE increases with the increase in the number of SPEs. We also experiment with various parameters, such as number of subsets, number of processing elements, and number of DMA transfers between main memory and local memory, that impact the performance of the algorithm.

  2. Laser-wakefield accelerators for medical phase contrast imaging: Monte Carlo simulations and experimental studies

    Science.gov (United States)

    Cipiccia, S.; Reboredo, D.; Vittoria, Fabio A.; Welsh, G. H.; Grant, P.; Grant, D. W.; Brunetti, E.; Wiggins, S. M.; Olivo, A.; Jaroszynski, D. A.

    2015-05-01

    X-ray phase contrast imaging (X-PCi) is a very promising method of dramatically enhancing the contrast of X-ray images of microscopic weakly absorbing objects and soft tissue, which may lead to significant advancement in medical imaging with high-resolution and low-dose. The interest in X-PCi is giving rise to a demand for effective simulation methods. Monte Carlo codes have been proved a valuable tool for studying X-PCi including coherent effects. The laser-plasma wakefield accelerators (LWFA) is a very compact particle accelerator that uses plasma as an accelerating medium. Accelerating gradient in excess of 1 GV/cm can be obtained, which makes them over a thousand times more compact than conventional accelerators. LWFA are also sources of brilliant betatron radiation, which are promising for applications including medical imaging. We present a study that explores the potential of LWFA-based betatron sources for medical X-PCi and investigate its resolution limit using numerical simulations based on the FLUKA Monte Carlo code, and present preliminary experimental results.

  3. Planetary method to measure the neutrons spectrum in lineal accelerators of medical use

    International Nuclear Information System (INIS)

    Vega C, H. R.; Benites R, J. L.

    2014-08-01

    A novel procedure to measure the neutrons spectrum originated in a lineal accelerator of medical use has been developed. The method uses a passive spectrometer of Bonner spheres. The main advantage of the method is that only requires of a single shot of the accelerator. When this is used around a lineal accelerator is necessary to operate it under the same conditions so many times like the spheres that contain the spectrometer, activity that consumes enough time. The developed procedure consists on situating all the spheres of the spectrometer at the same time and to realize the reading making a single shot. With this method the photo neutrons spectrum produced by a lineal accelerator Varian ix of 15 MV to 100 cm of the isocenter was determined, with the spectrum is determined the total flow and the ambient dose equivalent. (Author)

  4. Using films and television shows with a medical theme as a medium to accelerate the spread of medical humanities.

    Science.gov (United States)

    Chen, Wenting; Qian, Haihong

    2017-05-23

    People have more visual experiences than ever before, and the same is true for situations in medicine. More mature films and television shows with a medical theme have been available over the past 20 years. In mainland China, the TV series "Angel Heart" has generated a wave of universal concern since it truly depicts the work of health care workers and it reflects the sharp distinction between doctors and patients to a certain extent. Riding this wave, many medical documentaries like The Human World have also been launched in China and have garnered sizable audiences. Such films and television shows with a medical theme strive to depict the lives of ordinary people. When watching these medical documentaries, audiences are able to better comprehend the work of health care workers in light of their life experiences and feelings towards current society. Audiences can gain a profound understanding of the medical humanities through films and television shows with a medical theme. We look forward to more such films and television shows with a medical theme that depict "hospitals-the realest place" on camera. Films and television shows with a medical theme can serve as a storytelling medium to accelerate the spread of medical humanities and to promote harmony among doctors, patients, and the public.

  5. Accelerators

    CERN Multimedia

    CERN. Geneva

    2001-01-01

    The talk summarizes the principles of particle acceleration and addresses problems related to storage rings like LEP and LHC. Special emphasis will be given to orbit stability, long term stability of the particle motion, collective effects and synchrotron radiation.

  6. Radiant Ceiling Panels Combined with Localized Methods for Improved Thermal Comfort of Both Patient and Medical Staff in Patient Room

    DEFF Research Database (Denmark)

    Mori, Sakura; Barova, Mariya; Bolashikov, Zhecho Dimitrov

    2012-01-01

    The objectives were to identify whether ceiling installed radiant heating panels can provide thermal comfort to the occupants in a patient room, and to determine a method for optimal thermal environment to both patient and medical staff simultaneously. The experiments were performed in a climate...... mattress were used to provide local heating for the patient. The effects of the methods were identified by comparing the manikin based equivalent temperatures. The optimal thermal comfort level for both patient and medical staff would obtained when two conventional cotton blankets were used with extra...... chamber resembling a single-bed patient room under convective air conditioning alone or combined with the ceiling installed radiant heating panels. Two thermal manikins simulated a patient lying in the bed and a doctor standing next to the patient. Conventional cotton blanket, electric blanket, electric...

  7. Accelerating medical innovation at USC: realizing the dream of Alfred E. Mann.

    Science.gov (United States)

    Gosset, Nathalie; Lasch, Jonathan G

    2012-07-01

    Alfred E. Mann's vision is to create organizations that will help medical innovations born in academic environments evolve into commercially fit solutions, without the risk of being abandoned under the financial pressures early stage start-ups often experience. In 1998, Mann worked with Stephen Sample, president of USC, to create the first AMI for Biomedical Engineering, an organization fueled by an endowment valued at approximately US$160 million today. Technology-acceleration centers come in different flavors. AMI USC's recipe has evolved since its creation, with edits that incorporate lessons learned and improvements brought by its expanding network of talented resource people. Its 15-member staff, consisting of three-fourths industry professionals, includes seasoned generalists and specialists in medical technology commercialization. Although the support varies with each invention, some recurring ingredients weave into the AMI approach to accelerating medical innovation.

  8. Associated Roles of Perioperative Medical Directors and Anesthesia: Hospital Agreements for Operating Room Management.

    Science.gov (United States)

    Dexter, Franklin; Epstein, Richard H

    2015-12-01

    As reviewed previously, decision making can be made systematically shortly before the day of surgery based on reducing the hours of overutilized operating room (OR) time and tardiness of case starts (i.e., patient waiting). We subsequently considered in 2008 that such decision making depends on rational anesthesia-hospital agreements specifying anesthesia staffing. Since that prior study, there has been a substantial increase in understanding of the timing of decision making to reduce overutilized OR time. Most decisions substantively influencing overutilized OR time are those made within 1 workday before the day of surgery and on the day of surgery, because only then are ORs sufficiently full that case scheduling and staff assignment decisions affect overutilized OR time. Consequently, anesthesiologists can easily be engaged in such decisions, because generally they must be involved to ensure that the corresponding anesthesia staff assignments are appropriate. Despite this, at hospitals with >8 hours of OR time used daily in each OR, computerized recommendations are superior to intuition because of cognitive biases. Decisions need to be made by a Perioperative Medical Director who has knowledge of the principles of perioperative managerial decision making published in the scientific literature rather than by a committee lacking this competency. Education in the scientific literature, and when different analytical methods should be used, is important. The addition that we make in this article is to show that an agreement between an anesthesia group and a hospital can both reduce overutilized OR time and patient waiting: The anesthesia group and hospital will ensure, hourly, that, when there are case(s) waiting to start, the number of ORs in use for each service will be at least the number that maximizes the efficiency of use of OR time. Neither the anesthesia group nor the hospital will be expected to run more than that number of ORs without mutual agreement

  9. Use of bubbles dosemeters to measure the neutrons leakage radiations around a medical accelerator

    International Nuclear Information System (INIS)

    Bourgois, L.

    1999-01-01

    In this study, the neutron component has been determined on a medical accelerator (Saturne 43F type accelerator) with the help of bubbles detectors marketed by the Bubble Technology Industry society. BD-PND type dosemeters with sensitivities from 0.1 to 0.23 bubbles/micro sievert have been used. These dosemeters have important advantages: they are small enough and then, homogeneously irradiated, they are insensitive to intense electromagnetic fields and to photons and electrons, they can used several times by compression, the reading of the device does not need expensive means and it is possible to multiply the measure points. (N.C.)

  10. Americium-241 use of measurement lead equivalent thickness for medical x-ray room: A review

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Husaini Saleh; Abd Aziz Mhd Ramli; Muhammad Jamal Md Isa; Mohd Firdaus Abd Rahman; Zainal Jamaluddin

    2010-01-01

    Lead equivalent thickness measurement of a shielding material in diagnostic radiology is very important to ensure that requirements for the purpose of radiation protection of patients, employees and the public are met. The Malaysian Ministry of Health (MOH) has established that the irradiation room must have sufficient shielding thickness, for example for general radiography it must be at least equal to 2.0 mm of Pb, for panoramic dental radiography at least equal to 1.5 mm of Pb and for mammography should be a minimum of 1.0 mm of Pb. This paper presents a technique using americium-241 source to test and verify the integrity of the shielding thickness in term of lead equivalent for X-ray room at health centres. Results of measurement of 30 irradiation rooms conducted from 2009 to mid 2010 were analyzed for this presentation. Technical comparison of the attenuation of gamma rays from Am-241 source through the walls of the irradiation room and pieces of lead were used to assess the lead equivalent thickness of the walls. Results showed that 96.7 % of the irradiation rooms tested meet the requirements of the Ministry of Health and is suitable for the installation of the intended diagnostic X-ray apparatus. Some specific positions such as door knobs and locks, electrical plug sockets were identified with potential to not met the required lead equivalent thickness hence may contribute to higher radiation exposure to workers and the public. (author)

  11. Dose levels due to neutrons in the vicinity of high energy medical accelerators

    International Nuclear Information System (INIS)

    McGinley, P.H.; Wood, M.; Sohrabi, M.; Mills, M.; Rodriguez, R.

    1976-01-01

    High energy photons are generated for use in radiation therapy by the decelleration of electrons in metal targets. Fast neutrons are also generated as a result of (γ, n) and (e, e'n) interactions in the target, beam compensator filter, and collimator material. In this work the adsorbed dose to neutrons was measured at the center of a 10 x 10 cm photon beam and 5 cm outside of the beam edge for a number of treatment units. Dose levels due to slow and fast neutrons were also established outside of the treatment rooms and a Bonner sphere neutron spectrometer system was employed to determine the neutron energy spectrum due to stray neutron radiation at each accelerator. For the linac it was found that the neutron dose at the beam center was 0.0039% of the photon dose and values of 0.049% and 0.053% were observed for the Allis Chalmers betatron and the Brown Boveri Betatron. Dose equivalent rates in the range of 0.3 to 22.5 mrem/hr were measured for points outside the treatment rooms when the accelerators were operated at a photon dose rate of 100 rad/min at the treatment position

  12. Shielding of medically used proton accelerators; Abschirmung von medizinisch genutzten Protonenbeschleunigern

    Energy Technology Data Exchange (ETDEWEB)

    Ewen, Klaus

    2014-10-01

    In several standards of the standards committee radiology (NRA) the shielding of proton accelerators (cyclotrons) for medical utilization is described. Proton beams can be used in nuclear medicine for PET (proton emission tomography) isotope production or for radiotherapeutic use. The dominating radiation from proton induced nuclear reactions is fast neutron radiation. The calculation procedure for appropriate shielding measures according to the NAR standards is described step-by-step. AN adequate shielding of fast neutrons is also sufficient for the generated gamma radiation.

  13. Frontier of Advanced Accelerator Applications and Medical Treatments Using Nuclear Techniques. Abstract

    International Nuclear Information System (INIS)

    2015-01-01

    To address the challenges of research-based practice, developing advanced accelerator applications, and medical treatments using nuclear tecniqoes, researchers from Rajamakala University of Technology Lanna, Office of Atoms for Peace, and Chiang Mai University have joined in hosting this conference. Nuclear medicine, amedical specialty, diagnoses and treats diseases in a safe and painless way. Nuclear techniques can determine medical information that may otherwise be unavailable, require surgery, or necessitate more expensive and invasive diagnostic tests. Advance in nuclear techniques also offer the potential to detect abnormalities at earlier stages, leasding to earlier treatment and a more successful prognosis.

  14. A review of ion sources for medical accelerators (invited)a)

    Science.gov (United States)

    Muramatsu, M.; Kitagawa, A.

    2012-02-01

    There are two major medical applications of ion accelerators. One is a production of short-lived isotopes for radionuclide imaging with positron emission tomography and single photon emission computer tomography. Generally, a combination of a source for negative ions (usually H- and/or D-) and a cyclotron is used; this system is well established and distributed over the world. Other important medical application is charged-particle radiotherapy, where the accelerated ion beam itself is being used for patient treatment. Two distinctly different methods are being applied: either with protons or with heavy-ions (mostly carbon ions). Proton radiotherapy for deep-seated tumors has become widespread since the 1990s. The energy and intensity are typically over 200 MeV and several 1010 pps, respectively. Cyclotrons as well as synchrotrons are utilized. The ion source for the cyclotron is generally similar to the type for production of radioisotopes. For a synchrotron, one applies a positive ion source in combination with an injector linac. Carbon ion radiotherapy awakens a worldwide interest. About 6000 cancer patients have already been treated with carbon beams from the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan. These clinical results have clearly verified the advantages of carbon ions. Heidelberg Ion Therapy Center and Gunma University Heavy Ion Medical Center have been successfully launched. Several new facilities are under commissioning or construction. The beam energy is adjusted to the depth of tumors. It is usually between 140 and 430 MeV/u. Although the beam intensity depends on the irradiation method, it is typically several 108 or 109 pps. Synchrotrons are only utilized for carbon ion radiotherapy. An ECR ion source supplies multi-charged carbon ions for this requirement. Some other medical applications with ion beams attract developer's interests. For example, the several types of accelerators are under

  15. Evaluation of the Accelerate Pheno System: Results from Two Academic Medical Centers.

    Science.gov (United States)

    Lutgring, Joseph D; Bittencourt, Cassiana; McElvania TeKippe, Erin; Cavuoti, Dominick; Hollaway, Rita; Burd, Eileen M

    2018-04-01

    Rapid diagnostic tests are needed to improve patient care and to combat the problem of antimicrobial resistance. The Accelerate Pheno system (Accelerate Diagnostics, Tucson, AZ) is a new diagnostic device that can provide rapid bacterial identification and antimicrobial susceptibility test (AST) results directly from a positive blood culture. The device was compared to the standard of care at two academic medical centers. There were 298 blood cultures included in the study, and the Accelerate Pheno system provided a definitive identification result in 218 instances (73.2%). The Accelerate Pheno system provided a definitive and correct result for 173 runs (58.1%). The Accelerate Pheno system demonstrated an overall sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 94.7%, 98.9%, 83.7%, and 99.7%, respectively. An AST result was available for analysis in 146 instances. The overall category agreement was 94.1% with 12 very major errors, 5 major errors, and 55 minor errors. After a discrepancy analysis, there were 5 very major errors and 4 major errors. The Accelerate Pheno system provided an identification result in 1.4 h and an AST result in 6.6 h; the identification and AST results were 41.5 h and 48.4 h faster than those with the standard of care, respectively. This study demonstrated that the Accelerate Pheno system is able to provide fast and accurate organism identification and AST data. A limitation is the frequency with which cultures required the use of alternative identification and AST methods. Copyright © 2018 American Society for Microbiology.

  16. EURADOS intercomparison exercise on Monte Carlo modelling of a medical linear accelerator.

    Science.gov (United States)

    Caccia, Barbara; Le Roy, Maïwenn; Blideanu, Valentin; Andenna, Claudio; Arun, Chairmadurai; Czarnecki, Damian; El Bardouni, Tarek; Gschwind, Régine; Huot, Nicolas; Martin, Eric; Zink, Klemens; Zoubair, Mariam; Price, Robert; de Carlan, Loïc

    2017-01-01

    In radiotherapy, Monte Carlo (MC) methods are considered a gold standard to calculate accurate dose distributions, particularly in heterogeneous tissues. EURADOS organized an international comparison with six participants applying different MC models to a real medical linear accelerator and to one homogeneous and four heterogeneous dosimetric phantoms. The aim of this exercise was to identify, by comparison of different MC models with a complete experimental dataset, critical aspects useful for MC users to build and calibrate a simulation and perform a dosimetric analysis. Results show on average a good agreement between simulated and experimental data. However, some significant differences have been observed especially in presence of heterogeneities. Moreover, the results are critically dependent on the different choices of the initial electron source parameters. This intercomparison allowed the participants to identify some critical issues in MC modelling of a medical linear accelerator. Therefore, the complete experimental dataset assembled for this intercomparison will be available to all the MC users, thus providing them an opportunity to build and calibrate a model for a real medical linear accelerator.

  17. Assessment of abuse-related injuries: a comparative study of forensic physicians, emergency room physicians, emergency room nurses and medical students.

    Science.gov (United States)

    Reijnders, Udo J L; Giannakopoulos, Georgios F; de Bruin, Kim H

    2008-01-01

    A comparative study was made investigating whether emergency room physicians, emergency room nurses, forensic physicians, and interns are competent in describing, recognising and determining the possible cause of injuries. The injury assessment scores varied from good--adequate--fail and remained blank in various participant groups. Forensic physicians scored significantly better than emergency room staff and interns in the assessment of abuse-related injuries. There were almost no differences noted between emergency room physicians and emergency room nurses. For the functional group with more or less than 4 to 6 years of experience, no significant differences were noted for scoring good in all 5 cases. The fact that forensic physicians scored better than the emergency room staff is probably explained by the fact that almost all practicing forensic physicians have been officially qualified. Training in this field for all professionals involved in such assessment should be mandatory.

  18. A Study of the Operating Room Scheduling System at Tripler Army Medical Center, Hawaii

    Science.gov (United States)

    1981-08-01

    PROCESSING CLASS V SYSTEM .... .......... . A BIBLIOGRAPHY ....... ........... . . . .. . ii ’I. INTRODUCTIO9 Development of the Problem Convinced that...of the most difficult administrativo tasks that a modern hospital must face, and proposed using a combination of a master posting sheet and a...deal with scheduling problems.9 This particular process also incorporates the two-room system doscribed earlier, and the author admits that this

  19. The Psychoactive Effects of Psychiatric Medication: The Elephant in the Room

    OpenAIRE

    Moncrieff, J; Cohen, D; Porter, S

    2013-01-01

    The psychoactive effects of psychiatric medications have been obscured by the presumption that these medications have disease-specific actions. Exploiting the parallels with the psychoactive effects and uses of recreational substances helps to highlight the psychoactive properties of psychiatric medications and their impact on people with psychiatric problems. We discuss how psychoactive effects produced by different drugs prescribed in psychiatric practice might modify various disturbing and...

  20. Introducing Gross Pathology to Undergraduate Medical Students in the Dissecting Room

    Science.gov (United States)

    Wood, Andrew; Struthers, Kate; Whiten, Susan; Jackson, David; Herrington, C. Simon

    2010-01-01

    Pathology and anatomy are both sciences that contribute to the foundations of a successful medical career. In the past decade, medical education has undergone profound changes with the development of a core curriculum combined with student selected components. There has been a shift from discipline-based teaching towards problem-based learning.…

  1. Assessment of Clinical Stressful Factors Among Academic Students of Nursing and Operating Room of Dezful University of Medical Sciences (2015

    Directory of Open Access Journals (Sweden)

    Mojtaba Raji

    2016-07-01

    Full Text Available Background and Objective: Nursing students are exposed to clinical environmental stresses in addition to educational environmental stresses. The aim of this study was to assessment of clinical stressful factors among Academic Students of Nursing and Operating Room of Dezful University of Medical Sciences in 2015.Materials and Methods: This study was a description-analytical study with 234 students of nursing and operation room up to two semesters for enrolled. Data was using a self-made researcher Questionnaire consisted of demographic information and clinical stressful factors. Data analysis was performed by descriptive and inferential statistics using SPSS-PC (v.20.Results: The findings showed that the main stressors in students of nursing and operation room were unpleasant emotions and least stressful areas were interpersonal communication in a clinical environment. The results showed that the average score of the field of education and humiliating experiences using Spearman correlation test (P=0/045 (r=0/16.Conclusion: Study showed, the mean stress is the moderate level. Stressful areas obtained in the four areas of personal communication, clinical practice stressful, unpleasant feelings and humiliating experience that fortunately, in many cases reform and change.

  2. Failure modes and effects criticality analysis and accelerated life testing of LEDs for medical applications

    Science.gov (United States)

    Sawant, M.; Christou, A.

    2012-12-01

    While use of LEDs in Fiber Optics and lighting applications is common, their use in medical diagnostic applications is not very extensive. Since the precise value of light intensity will be used to interpret patient results, understanding failure modes [1-4] is very important. We used the Failure Modes and Effects Criticality Analysis (FMECA) tool to identify the critical failure modes of the LEDs. FMECA involves identification of various failure modes, their effects on the system (LED optical output in this context), their frequency of occurrence, severity and the criticality of the failure modes. The competing failure modes/mechanisms were degradation of: active layer (where electron-hole recombination occurs to emit light), electrodes (provides electrical contact to the semiconductor chip), Indium Tin Oxide (ITO) surface layer (used to improve current spreading and light extraction), plastic encapsulation (protective polymer layer) and packaging failures (bond wires, heat sink separation). A FMECA table is constructed and the criticality is calculated by estimating the failure effect probability (β), failure mode ratio (α), failure rate (λ) and the operating time. Once the critical failure modes were identified, the next steps were generation of prior time to failure distribution and comparing with our accelerated life test data. To generate the prior distributions, data and results from previous investigations were utilized [5-33] where reliability test results of similar LEDs were reported. From the graphs or tabular data, we extracted the time required for the optical power output to reach 80% of its initial value. This is our failure criterion for the medical diagnostic application. Analysis of published data for different LED materials (AlGaInP, GaN, AlGaAs), the Semiconductor Structures (DH, MQW) and the mode of testing (DC, Pulsed) was carried out. The data was categorized according to the materials system and LED structure such as AlGaInP-DH-DC, Al

  3. The effects of dissection-room experiences and related coping strategies among Hungarian medical students

    OpenAIRE

    S?ndor, Imola; Birk?s, Emma; Gy?rffy, Zsuzsa

    2015-01-01

    Background Students get their first experiences of dissecting human cadavers in the practical classes of anatomy and pathology courses, core components of medical education. These experiences form an important part of the process of becoming a doctor, but bring with them a special set of problems. Methods Quantitative, national survey (n?=?733) among medical students, measured reactions to dissection experiences and used a new measuring instrument to determine the possible factors of coping. ...

  4. The issue of thermal comfort of medical clothing in the operating room

    OpenAIRE

    Abreu, Isabel; Ribeiro, Patrícia; Abreu, Maria José

    2017-01-01

    Abstract Medical clothes have the primary function of protection. However this function must be correlated with a good comfort experience to the user. The comfort is a very important issue, since professionals are exposed to stress situations that can influence, negatively, their performance work. More specific, thermal comfort plays a crucial role for the best performance of OR medical clothing, involving heat regulation and mass transfer between a clothed body and the environment, once clot...

  5. A study on the calculation of the shielding wall thickness in medical linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Yeon [Dept. of Radiation Oncology, Dongnam Ins. of Radiological and Medical Science, Busan (Korea, Republic of); Park, Eun Tae [Dept. of Radiation Oncology, Inje University Busan Paik Hospital, Busan (Korea, Republic of); Kim, Jung Hoon [Dept. of Radiological science, college of health sciences, Catholic University of Pusan, Busan (Korea, Republic of)

    2017-06-15

    The purpose of this study is to calculate the thickness of shielding for concrete which is mainly used for radiation shielding and study of the walls constructed to shield medical linear accelerator. The optimal shielding thickness was calculated using MCNPX(Ver.2.5.0) for 10 MV of photon beam energy generated by linear accelerator. As a result, the TVL for photon shielding was formed at 50⁓100 cm for pure concrete and concrete with Boron+polyethylene at 80⁓100 cm. The neutron shielding was calculated 100⁓140 cm for pure concrete and concrete with Boron+polyethylene at 90⁓100 cm. Based on this study, the concrete is considered to be most efficient method of using steel plates and adding Boron+polyethylene th the concrete.

  6. Study of behaviour of the monitor chambers of a linear accelerator for medical use

    International Nuclear Information System (INIS)

    Brosed, A.; Lopez-Bote, M.A.; Blanco, M.A.; Galvez, M.

    1988-01-01

    An experimental procedure to study the nature and behaviour of the monitor chambers of a linear accelerator for medical use is presented. The procedure has been applied to a Siemens accelerator, Mevatron-77, that has two different types of monitor chambers: sealed for the photon beam and unsealed for the electron ones. As it was expected, no deviations in the dose per monitor unit has been obtained for the photon beam. Variations in the absorbed dose per monitor unit have been observed for the electron beams up to 6% along the working day. Practical solutions compensating this fact are pointed out and the standard recommendations on the control of dose per monitor unit are discussed. (Author)

  7. Monte Carlo simulation of a medical linear accelerator for radiotherapy use

    International Nuclear Information System (INIS)

    Serrano, B.; Hachem, A.; Franchisseur, E.; Herault, J.; Marcie, S.; Costa, A.; Bensadoun, R. J.; Barthe, J.; Gerard, J. P.

    2006-01-01

    A Monte Carlo code MCNPX (Monte Carlo N-particle) was used to model a 25 MV photon beam from a PRIMUS (KD2-Siemens) medical linear electron accelerator at the Centre Antoine Lacassagne in Nice. The entire geometry including the accelerator head and the water phantom was simulated to calculate the dose profile and the relative depth-dose distribution. The measurements were done using an ionisation chamber in water for different square field ranges. The first results show that the mean electron beam energy is not 19 MeV as mentioned by Siemens. The adjustment between the Monte Carlo calculated and measured data is obtained when the mean electron beam energy is ∼15 MeV. These encouraging results will permit to check calculation data given by the treatment planning system, especially for small fields in high gradient heterogeneous zones, typical for intensity modulated radiation therapy technique. (authors)

  8. A quality control method for detecting energy changes of medical accelerators

    International Nuclear Information System (INIS)

    McGinley, P.H.

    2000-01-01

    A description is presented of a simple and sensitive method for detecting a change in the energy of the electrons bombarding the target of medical accelerators. This technique is useful for x-ray beams with end point energy in the range of 15.7 to 25 MeV. The method is based on the photoactivation of 16 O and 14 N in a small sample of ammonium nitrate. It was found that the ratio of the activity induced in the oxygen divided by that produced in the nitrogen can be used as a quality control technique to detect a change in the energy of the electrons that bombard the target of the accelerator. An electron energy change of the order of 0.2 MeV can be determined using this method. (author)

  9. Laser Radiation Pressure Accelerator for Quasi-Monoenergetic Proton Generation and Its Medical Implications

    Science.gov (United States)

    Liu, C. S.; Shao, X.; Liu, T. C.; Su, J. J.; He, M. Q.; Eliasson, B.; Tripathi, V. K.; Dudnikova, G.; Sagdeev, R. Z.; Wilks, S.; Chen, C. D.; Sheng, Z. M.

    Laser radiation pressure acceleration (RPA) of ultrathin foils of subwavelength thickness provides an efficient means of quasi-monoenergetic proton generation. With an optimal foil thickness, the ponderomotive force of the intense short-pulse laser beam pushes the electrons to the edge of the foil, while balancing the electric field due to charge separation. The electron and proton layers form a self-organized plasma double layer and are accelerated by the radiation pressure of the laser, the so-called light sail. However, the Rayleigh-Taylor instability can limit the acceleration and broaden the energy of the proton beam. Two-dimensional particle-in-cell (PIC) simulations have shown that the formation of finger-like structures due to the nonlinear evolution of the Rayleigh-Taylor instability limits the acceleration and leads to a leakage of radiation through the target by self-induced transparency. We here review the physics of quasi-monoenergetic proton generation by RPA and recent advances in the studies of energy scaling of RPA, and discuss the RPA of multi-ion and gas targets. The scheme for generating quasi-monoenergetic protons with RPA has the potential of leading to table-top accelerators as sources for producing monoenergetic 50-250 MeV protons. We also discuss potential medical implications, such as particle therapy for cancer treatment, using quasi-monoenergetic proton beams generated from RPA. Compact monoenergetic ion sources also have applications in many other areas such as high-energy particle physics, space electronics radiation testing, and fast ignition in laser fusion.

  10. Errors in the administration of intravenous medications in patients undergoing anesthesia in the operating room

    Directory of Open Access Journals (Sweden)

    Juan David Miranda

    2013-03-01

    Full Text Available Errors in medication administration have affected the anesthetic practice over the time and have become a major cause of perioperative morbidity and mortality. Among different medical specialties, anesthesiology is perhaps the most likely to make mistakes in this procedure. This is because in many places around the world, a single professional "anesthesiologist" orders, prepares and administers a drug at one time and setting. For thirty years, Cooper disclosed the first reports of critical incidents and perioperative safety scheme, and in the 90s', Chopra performed a retrospective analysis, found that medication errors are the fourth most common that results in disability in 17% and death in 8%, these being preventable errors in 51% of cases. It’s essential for the safe practice of anesthesia to establish interventions for improving prevention programs, education, research and development, enabling break traditional paradigms, with the aim of making recommendations and standardize the safe administration of drugs in this field.

  11. Status on the compilation of nuclear data for medical radioisotopes produced by accelerators

    International Nuclear Information System (INIS)

    Gandarias-Cruz, D.; Okamoto, K.

    1988-10-01

    The status of data on excitation functions and thick target yields for medical radioisotopes produced by accelerators is summarized. Most of the information was extracted from the compiled data in EXFOR (EXCHANGE FORMAT) which is a common format used by the co-operating nuclear data centres in the world. The nuclear decay mode, half-life, production method, Q-value, maximum cross-section value and the energy at this maximum, are tabulated. For some commonly used reactions, the available excitation functions are plotted in graph. (author). 353 refs

  12. Verification of radiodynamic therapy by medical linear accelerator using a mouse melanoma tumor model.

    Science.gov (United States)

    Takahashi, Junko; Murakami, Mami; Mori, Takashi; Iwahashi, Hitoshi

    2018-02-09

    Combined treatment with 5-aminolevulinic acid (5-ALA) and X-rays improves tumor suppression in vivo. This is because the accumulated protoporphyrin IX from 5-ALA enhances the generation of ROS by the X-ray irradiation. In the present study, a high-energy medical linear accelerator was used instead of a non-medical low energy X-ray irradiator, which had been previously used. Tumor-bearing mice implanted with B16-BL6 melanoma cells were treated with fractionated doses of irradiation (in total, 20 or 30 Gy), using two types of X-ray irradiator after 5-ALA administration. Suppression of tumor growth was enhanced with X-ray irradiation in combination with 5-ALA treatment compared with X-ray treatment alone, using both medical and non-medical X-ray irradiators. 5-ALA has been used clinically for photodynamic therapy. Thus, "radiodynamic therapy", using radiation from medical linacs as a physical driving force, rather than the light used in photodynamic therapy, may have potential clinical applications.

  13. The psychoactive effects of psychiatric medication: the elephant in the room.

    Science.gov (United States)

    Moncrieff, Joanna; Cohen, David; Porter, Sally

    2013-01-01

    The psychoactive effects of psychiatric medications have been obscured by the presumption that these medications have disease-specific actions. Exploiting the parallels with the psychoactive effects and uses of recreational substances helps to highlight the psychoactive properties of psychiatric medications and their impact on people with psychiatric problems. We discuss how psychoactive effects produced by different drugs prescribed in psychiatric practice might modify various disturbing and distressing symptoms, and we also consider the costs of these psychoactive effects on the mental well-being of the user. We examine the issue of dependence, and the need for support for people wishing to withdraw from psychiatric medication. We consider how the reality of psychoactive effects undermines the idea that psychiatric drugs work by targeting underlying disease processes, since psychoactive effects can themselves directly modify mental and behavioral symptoms and thus affect the results of placebo-controlled trials. These effects and their impact also raise questions about the validity and importance of modern diagnosis systems. Extensive research is needed to clarify the range of acute and longer-term mental, behavioral, and physical effects induced by psychiatric drugs, both during and after consumption and withdrawal, to enable users and prescribers to exploit their psychoactive effects judiciously in a safe and more informed manner.

  14. Sedative medications outside the operating room and the pharmacology of sedatives

    DEFF Research Database (Denmark)

    Hansen, Tom G

    2015-01-01

    PURPOSE OF REVIEW: There is a growing medical demand for suitable sedatives and analgesics to support the ongoing progress in diagnostic procedures and imaging techniques. This review provides an update of the pharmacology of the most commonly used drugs used for these procedures and shortly...

  15. Is single room hospital accommodation associated with differences in healthcare-associated infection, falls, pressure ulcers or medication errors? A natural experiment with non-equivalent controls.

    Science.gov (United States)

    Simon, Michael; Maben, Jill; Murrells, Trevor; Griffiths, Peter

    2016-07-01

    A wide range of patient benefits have been attributed to single room hospital accommodation including a reduction in adverse patient safety events. However, studies have been limited to the US with limited evidence from elsewhere. The aim of this study was to assess the impact on safety outcomes of the move to a newly built all single room acute hospital. A natural experiment investigating the move to 100% single room accommodation in acute assessment, surgical and older people's wards. Move to 100% single room accommodation compared to 'steady state' and 'new build' control hospitals. Falls, pressure ulcer, medication error, meticillin-resistant Staphylococcus aureus and Clostridium difficile rates from routine data sources were measured over 36 months. Five of 15 time series in the wards that moved to single room accommodation revealed changes that coincided with the move to the new all single room hospital: specifically, increased fall, pressure ulcer and Clostridium difficile rates in the older people's ward, and temporary increases in falls and medication errors in the acute assessment unit. However, because the case mix of the older people's ward changed, and because the increase in falls and medication errors on the acute assessment ward did not last longer than six months, no clear effect of single rooms on the safety outcomes was demonstrated. There were no changes to safety events coinciding with the move at the new build control site. For all changes in patient safety events that coincided with the move to single rooms, we found plausible alternative explanations such as case-mix change or disruption as a result of the re-organization of services after the move. The results provide no evidence of either benefit or harm from all single room accommodation in terms of safety-related outcomes, although there may be short-term risks associated with a move to single rooms. © The Author(s) 2016.

  16. Fixed Field Alternating Gradient (FFAG)accelerators and their medical application in proton therapy

    International Nuclear Information System (INIS)

    Fourrier, J.

    2008-10-01

    Radiotherapy uses particle beams to irradiate and kill cancer tumors while sparing healthy tissues. Bragg peak shape of the proton energy loss in matter allows a ballistic improvement of the dose deposition compared with X rays. Thus, the irradiated volume can be precisely adjusted to the tumour. This thesis, in the frame of the RACCAM project, aims to the study and the design of a proton therapy installation based on a fixed field alternating gradient (FFAG) accelerator in order to build a spiral sector FFAG magnet for validation. First, we present proton therapy to define medical specifications leading to the technical specifications of a proton therapy installation. Secondly, we introduce FFAG accelerators through their past and on-going projects which are on their way around the world before developing the beam dynamic theories in the case of invariant focusing optics (scaling FFAG). We describe modelling and simulation tools developed to study the dynamics in a spiral scaling FFAG accelerator. Then we explain the spiral optic parameter search which has leaded to the construction of a magnet prototype. Finally, we describe the RACCAM project proton therapy installation starting from the injector cyclotron and ending with the extraction system. (author)

  17. Medical linear accelerator mounted mini-beam collimator: design, fabrication and dosimetric characterization.

    Science.gov (United States)

    Cranmer-Sargison, G; Crewson, C; Davis, W M; Sidhu, N P; Kundapur, V

    2015-09-07

    The goal of this work was to design, build and experimentally characterize a linear accelerator mounted mini-beam collimator for use at a nominal 6 MV beam energy. Monte Carlo simulation was used in the design and dosimetric characterization of a compact mini-beam collimator assembly mounted to a medical linear accelerator. After fabrication, experimental mini-beam dose profiles and central axis relative output were measured and the results used to validate the simulation data. The simulation data was then used to establish traceability back to an established dosimetric code of practice. The Monte Carlo simulation work revealed that changes in collimator blade width have a greater influence on the valley-to-peak dose ratio than do changes in blade height. There was good agreement between the modeled and measured profile data, with the exception of small differences on either side of the central peak dose. These differences were found to be systematic across all depths and result from limitations associated with the collimator fabrication. Experimental mini-beam relative output and simulation data agreed to better than ± 2.0%, which is well within the level of uncertainty required for dosimetric traceability of non-standard field geometries. A mini-beam collimator has now been designed, built and experimentally characterized for use with a commercial linear accelerator operated at a nominal 6 MV beam energy.

  18. Method for calculating required shielding in medical x-ray rooms

    International Nuclear Information System (INIS)

    Karppinen, J.

    1997-10-01

    The new annual radiation dose limits - 20 mSv (previously 50 mSv) for radiation workers and 1 mSv (previously 5 mSv) for other persons - implies that the adequacy of existing radiation shielding must be re-evaluated. In principle, one could assume that the thicknesses of old radiation shields should be increased by about one or two half-value layers in order to comply with the new dose limits. However, the assumptions made in the earlier shielding calculations are highly conservative; the required shielding was often determined by applying the maximum high-voltage of the x-ray tube for the whole workload. A more realistic calculation shows that increased shielding is typically not necessary if more practical x-ray tube voltages are used in the evaluation. We have developed a PC-based calculation method for calculating the x-ray shielding which is more realistic than the highly conservative method formerly used. The method may be used to evaluate an existing shield for compliance with new regulations. As examples of these calculations, typical x-ray rooms are considered. The lead and concrete thickness requirements as a function of x-ray tube voltage and workload are also given in tables. (author)

  19. Room for improvement: Palliating the ego in feedback-resistant medical students.

    Science.gov (United States)

    Perrella, Andrew

    2017-05-01

    Feedback in medical education provides the impetus for growth in a field pressured to demonstrate continuous progress. Unfortunately, as it always incorporates some level of judgment, certain students appear more resistant than receptive to receiving feedback. Coupled with the ubiquitous stressors of medicine-examinations, perpetual knowledge acquisition, competition for employment-there subtly emerges a learning environment in which the mindset of medical trainees morphs from collegiality to outperformance of one's peers. As the unconscious mind is ultimately focused on self-protection, the cognitive response of reflecting upon received feedback is overcome by an emotional response to safeguard one's self-image against criticism in a culture of comparison. Although self-confidence plays a critical role in mitigating burnout, the relationship between resiliency and ego-armoring is rarely discussed in the literature. Consequently, despite the best intentions of educators in fostering clinical maturity among their trainees, the fact remains that insecurity, inadequacy and invulnerability continue to drive feedback-resistance among medical students.

  20. A medical cost estimation with fuzzy neural network of acute hepatitis patients in emergency room.

    Science.gov (United States)

    Kuo, R J; Cheng, W C; Lien, W C; Yang, T J

    2015-10-01

    Taiwan is an area where chronic hepatitis is endemic. Liver cancer is so common that it has been ranked first among cancer mortality rates since the early 1980s in Taiwan. Besides, liver cirrhosis and chronic liver diseases are the sixth or seventh in the causes of death. Therefore, as shown by the active research on hepatitis, it is not only a health threat, but also a huge medical cost for the government. The estimated total number of hepatitis B carriers in the general population aged more than 20 years old is 3,067,307. Thus, a case record review was conducted from all patients with diagnosis of acute hepatitis admitted to the Emergency Department (ED) of a well-known teaching-oriented hospital in Taipei. The cost of medical resource utilization is defined as the total medical fee. In this study, a fuzzy neural network is employed to develop the cost forecasting model. A total of 110 patients met the inclusion criteria. The computational results indicate that the FNN model can provide more accurate forecasts than the support vector regression (SVR) or artificial neural network (ANN). In addition, unlike SVR and ANN, FNN can also provide fuzzy IF-THEN rules for interpretation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. AAPM Medical Physics Practice Guideline 8.a.: Linear accelerator performance tests.

    Science.gov (United States)

    Smith, Koren; Balter, Peter; Duhon, John; White, Gerald A; Vassy, David L; Miller, Robin A; Serago, Christopher F; Fairobent, Lynne A

    2017-07-01

    The purpose of this guideline is to provide a list of critical performance tests in order to assist the Qualified Medical Physicist (QMP) in establishing and maintaining a safe and effective quality assurance (QA) program. The performance tests on a linear accelerator (linac) should be selected to fit the clinical patterns of use of the accelerator and care should be given to perform tests which are relevant to detecting errors related to the specific use of the accelerator. A risk assessment was performed on tests from current task group reports on linac QA to highlight those tests that are most effective at maintaining safety and quality for the patient. Recommendations are made on the acquisition of reference or baseline data, the establishment of machine isocenter on a routine basis, basing performance tests on clinical use of the linac, working with vendors to establish QA tests and performing tests after maintenance. The recommended tests proposed in this guideline were chosen based on the results from the risk analysis and the consensus of the guideline's committee. The tests are grouped together by class of test (e.g., dosimetry, mechanical, etc.) and clinical parameter tested. Implementation notes are included for each test so that the QMP can understand the overall goal of each test. This guideline will assist the QMP in developing a comprehensive QA program for linacs in the external beam radiation therapy setting. The committee sought to prioritize tests by their implication on quality and patient safety. The QMP is ultimately responsible for implementing appropriate tests. In the spirit of the report from American Association of Physicists in Medicine Task Group 100, individual institutions are encouraged to analyze the risks involved in their own clinical practice and determine which performance tests are relevant in their own radiotherapy clinics. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on

  2. Statistical analysis of operating efficiency and failures of a medical linear accelerator for ten years

    International Nuclear Information System (INIS)

    Ju, Sang Gyu; Huh, Seung Jae; Han, Young Yih

    2005-01-01

    To improve the management of a medical linear accelerator, the records of operational failures of a Varian CL2100C over a ten year period were retrospectively analyzed. The failures were classified according to the involved functional subunits, with each class rated into one of three levels depending on the operational conditions. The relationships between the failure rate and working ratio and between the failure rate and outside temperature were investigated. In addition, the average life time of the main part and the operating efficiency over the last 4 years were analyzed. Among the recorded failures (total 587 failures), the most frequent failure was observed in the parts related with the collimation system, including the monitor chamber, which accounted for 20% of all failures. With regard to the operational conditions, 2nd level of failures, which temporally interrupted treatments, were the most frequent. Third level of failures, which interrupted treatment for more than several hours, were mostly caused by the accelerating subunit. The number of failures was increased with number of treatments and operating time. The average life-times of the Klystron and Thyratron became shorter as the working ratio increased, and were 42 and 83% of the expected values, respectively. The operating efficiency was maintained at 95% or higher, but this value slightly decreased. There was no significant correlation between the number of failures and the outside temperature. The maintenance of detailed equipment problems and failures records over a long period of time can provide good knowledge of equipment function as well as the capability of predicting future failure. More rigorous equipment maintenance is required for old medical linear accelerators for the advanced avoidance of serious failure and to improve the quality of patient treatment

  3. Calibration of PADC-based neutron area dosemeters in the neutron field produced in the treatment room of a medical LINAC

    International Nuclear Information System (INIS)

    Bedogni, R.; Domingo, C.; Esposito, A.; Gentile, A.; García-Fusté, M.J.; San-Pedro, M. de; Tana, L.; D’Errico, F.; Ciolini, R.; Di Fulvio, A.

    2013-01-01

    PADC-based nuclear track detectors have been widely used as convenient ambient dosemeters in many working places. However, due to the large energy dependence of their response in terms of ambient dose equivalent (H ∗ (10)) and to the diversity of workplace fields in terms of energy distribution, the appropriate calibration of these dosemeters is a delicate task. These are among the reasons why ISO has introduced the 12789 Series of Standards, where the simulated workplace neutron fields are introduced and their use to calibrate neutron dosemeters is recommended. This approach was applied in the present work to the UAB PADC-based nuclear track detectors. As a suitable workplace, the treatment room of a 15 MV Varian CLINAC DHX medical accelerator, located in the Ospedale S. Chiara (Pisa), was chosen. Here the neutron spectra in two points of tests (1.5 m and 2 m from the isocenter) were determined with the INFN-LNF Bonner Sphere Spectrometer equipped with Dysprosium activation foils (Dy-BSS), and the values of H ∗ (10) were derived on this basis. The PADC dosemeters were exposed in these points. Their workplace specific H*(10) responses were determined and compared with those previously obtained in different simulated workplace or reference (ISO 8529) neutron fields. - Highlights: ► The neutron field of a medical LINAC was used to calibrate PADC neutron dosemeters. ► The neutron spectra were derived with a Dy-foil based Bonner Sphere Spectrometer. ► Workplace specific calibration factor were derived for the PADC dosemeters. ► These factors were compared with those obtained in reference neutron fields

  4. Accelerating Improvements in the Energy Efficiency of Room Air Conditioners (RACs) in India: Potential, Cost-Benefit, and Policies (Interim Assessment)

    Energy Technology Data Exchange (ETDEWEB)

    Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-06-01

    Falling AC prices, increasing incomes, increasing urbanization, and high cooling requirements due to hot climate are all driving increasing uptake of Room Air Conditioners (RACs) in the Indian market. Air conditioning already comprises 40-60% of summer peak load in large metropolitan Indian cities such as Delhi and is likely to contribute 150 GW to the peak demand in 2030. Standards and labeling policies have contributed to improving the efficiency of RACs in India by about 2.5% in the last 10 years (2.5% per year) while inflation adjusted RAC prices have continued to decline. In this paper, we assess the technical feasibility, cost-benefit, and required policy enhancements by further accelerating the efficiency improvement of RACs in India. We find that there are examples of significantly more accelerated improvements such as those in Japan and Korea where AC efficiency improved by more than 7% per year resulting in almost a doubling of energy efficiency in 7 to 10 years while inflation adjusted AC prices continued to decline. We find that the most efficient RAC sold on the Indian market is almost twice as efficient as the typical AC sold on the market and hence see no technology constraints in a similar acceleration of improvement of efficiency. If starting 2018, AC efficiency improves at a rate of 6% instead of 3%, 40-60 GW of peak load (equivalent to connected load of 5-6 billion LED bulbs), and over 75 TWh/yr (equivalent to 60 million consumers consuming 100 kWh/month) will be saved by 2030; total peak load reduction would be as high as 50 GW. The net present value (NPV) of the consumer benefit between 2018-2030 will range from Rs 18,000 Cr in the most conservative case (in which prices don’t continue to decline and increase based estimates of today’s cost of efficiency improvement) to 140,000 Cr in a more realistic case (in which prices are not affected by accelerated efficiency improvement as shown by historical experience). This benefit is achievable by

  5. An investigation of performance characteristics of a pixellated room-temperature semiconductor detector for medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Guerra, P; Santos, A [Centro de Investigacion Biomedica de Bioningenieria, Biomateriales y Nanomedicina, CEEI-Modulo 3, C/ Maria de Luna, 11, 50018 Zaragoza (United States); Darambara, D G, E-mail: pguerra@ciber-bbn.e [Joint Department of Physics, Royal Marsden NHS Foundation Trust and Institute of Cancer Research, Fulham Road, London SW3 6JJ (United Kingdom)

    2009-09-07

    The operation of any semiconductor detector depends on the movement of the charge carriers, which are created within the material when radiation passes through, as a result of energy deposition. The carrier movement in the bulk semiconductor induces charges on the metal electrodes, and therefore a current on the electrodes and the external circuit. The induced charge strongly depends on the material transport parameters as well as the geometrical dimensions of a pixellated semiconductor detector. This work focuses on the performance optimization in terms of energy resolution, detection efficiency and intrinsic spatial resolution of a room-temperature semiconductor pixellated detector based on CdTe/CdZnTe. It analyses and inter-relates these performance figures for various dimensions of CdTe and CdZnTe detectors and for an energy range spanning from x-ray (25 keV) to PET (511 keV) imaging. Monte Carlo simulations, which integrate a detailed and accurate noise model, are carried out to investigate several CdTe/CdZnTe configurations and to determine possible design specifications. Under the considered conditions, the simulations demonstrate the superiority of the CdZnTe over the CdTe in terms of energy resolution and sensitivity in the photopeak. Further, according to the results, the spatial resolution is maximized at high energies and the energy resolution at low energies, while a reasonable detection efficiency is achieved at high energies, with a 1 x 1 x 6 mm{sup 3} CdZnTe pixellated detector.

  6. An investigation of performance characteristics of a pixellated room-temperature semiconductor detector for medical imaging

    International Nuclear Information System (INIS)

    Guerra, P; Santos, A; Darambara, D G

    2009-01-01

    The operation of any semiconductor detector depends on the movement of the charge carriers, which are created within the material when radiation passes through, as a result of energy deposition. The carrier movement in the bulk semiconductor induces charges on the metal electrodes, and therefore a current on the electrodes and the external circuit. The induced charge strongly depends on the material transport parameters as well as the geometrical dimensions of a pixellated semiconductor detector. This work focuses on the performance optimization in terms of energy resolution, detection efficiency and intrinsic spatial resolution of a room-temperature semiconductor pixellated detector based on CdTe/CdZnTe. It analyses and inter-relates these performance figures for various dimensions of CdTe and CdZnTe detectors and for an energy range spanning from x-ray (25 keV) to PET (511 keV) imaging. Monte Carlo simulations, which integrate a detailed and accurate noise model, are carried out to investigate several CdTe/CdZnTe configurations and to determine possible design specifications. Under the considered conditions, the simulations demonstrate the superiority of the CdZnTe over the CdTe in terms of energy resolution and sensitivity in the photopeak. Further, according to the results, the spatial resolution is maximized at high energies and the energy resolution at low energies, while a reasonable detection efficiency is achieved at high energies, with a 1 x 1 x 6 mm 3 CdZnTe pixellated detector.

  7. SU-E-J-137: Image Registration Tool for Patient Setup in Korea Heavy Ion Medical Accelerator Center

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M; Suh, T [Department of Biomedical Engineering, Research Institute of Biomedical Engineering, The Catholic University of Korea, Seoul (Korea, Republic of); Cho, W [Borame Medical Center, Seoul National University Hospital, Seoul, Seoul (Korea, Republic of); Jung, W [Korea Institute of Radiological & Medical Sciences, Seoul, Seoul (Korea, Republic of)

    2015-06-15

    Purpose: A potential validation tool for compensating patient positioning error was developed using 2D/3D and 3D/3D image registration. Methods: For 2D/3D registration, digitally reconstructed radiography (DRR) and three-dimensional computed tomography (3D-CT) images were applied. The ray-casting algorithm is the most straightforward method for generating DRR. We adopted the traditional ray-casting method, which finds the intersections of a ray with all objects, voxels of the 3D-CT volume in the scene. The similarity between the extracted DRR and orthogonal image was measured by using a normalized mutual information method. Two orthogonal images were acquired from a Cyber-Knife system from the anterior-posterior (AP) and right lateral (RL) views. The 3D-CT and two orthogonal images of an anthropomorphic phantom and head and neck cancer patient were used in this study. For 3D/3D registration, planning CT and in-room CT image were applied. After registration, the translation and rotation factors were calculated to position a couch to be movable in six dimensions. Results: Registration accuracies and average errors of 2.12 mm ± 0.50 mm for transformations and 1.23° ± 0.40° for rotations were acquired by 2D/3D registration using an anthropomorphic Alderson-Rando phantom. In addition, registration accuracies and average errors of 0.90 mm ± 0.30 mm for transformations and 1.00° ± 0.2° for rotations were acquired using CT image sets. Conclusion: We demonstrated that this validation tool could compensate for patient positioning error. In addition, this research could be the fundamental step for compensating patient positioning error at the first Korea heavy-ion medical accelerator treatment center.

  8. SU-E-J-137: Image Registration Tool for Patient Setup in Korea Heavy Ion Medical Accelerator Center

    International Nuclear Information System (INIS)

    Kim, M; Suh, T; Cho, W; Jung, W

    2015-01-01

    Purpose: A potential validation tool for compensating patient positioning error was developed using 2D/3D and 3D/3D image registration. Methods: For 2D/3D registration, digitally reconstructed radiography (DRR) and three-dimensional computed tomography (3D-CT) images were applied. The ray-casting algorithm is the most straightforward method for generating DRR. We adopted the traditional ray-casting method, which finds the intersections of a ray with all objects, voxels of the 3D-CT volume in the scene. The similarity between the extracted DRR and orthogonal image was measured by using a normalized mutual information method. Two orthogonal images were acquired from a Cyber-Knife system from the anterior-posterior (AP) and right lateral (RL) views. The 3D-CT and two orthogonal images of an anthropomorphic phantom and head and neck cancer patient were used in this study. For 3D/3D registration, planning CT and in-room CT image were applied. After registration, the translation and rotation factors were calculated to position a couch to be movable in six dimensions. Results: Registration accuracies and average errors of 2.12 mm ± 0.50 mm for transformations and 1.23° ± 0.40° for rotations were acquired by 2D/3D registration using an anthropomorphic Alderson-Rando phantom. In addition, registration accuracies and average errors of 0.90 mm ± 0.30 mm for transformations and 1.00° ± 0.2° for rotations were acquired using CT image sets. Conclusion: We demonstrated that this validation tool could compensate for patient positioning error. In addition, this research could be the fundamental step for compensating patient positioning error at the first Korea heavy-ion medical accelerator treatment center

  9. Evaluation of medical isotope production with the accelerator production of tritium (APT) facility

    International Nuclear Information System (INIS)

    Benjamin, R.W.; Frey, G.D.; McLean, D.C., Jr; Spicer, K.M.; Davis, S.E.; Baron, S.; Frysinger, J.R.; Blanpied, G.; Adcock, D.

    1997-01-01

    The accelerator production of tritium (APT) facility, with its high beam current and high beam energy, would be an ideal supplier of radioisotopes for medical research, imaging, and therapy. By-product radioisotopes will be produced in the APT window and target cooling systems and in the tungsten target through spallation, neutron, and proton interactions. High intensity proton fluxes are potentially available at three different energies for the production of proton- rich radioisotopes. Isotope production targets can be inserted into the blanket for production of neutron-rich isotopes. Currently, the major production sources of radioisotopes are either aging or abroad, or both. The use of radionuclides in nuclear medicine is growing and changing, both in terms of the number of nuclear medicine procedures being performed and in the rapidly expanding range of procedures and radioisotopes used. A large and varied demand is forecast, and the APT would be an ideal facility to satisfy that demand

  10. Assessment of beam stability of high energy and low energy Varian medical linear accelerators

    International Nuclear Information System (INIS)

    Jayesh, K.; Mohan, R.; Joshi, R.C.; Ganesh, T.; Hegazy, M.; Oubaye, A.J.; AI Idrisi, Maha

    2008-01-01

    An accurate measurement of the dose delivered to the tumor in external beam radiotherapy is one of the primary responsibilities of a medical physicist. In general, such measurements have been based on the application of a dosimetry protocol and quality assurance procedures. Clinically one must be able to assess the beam quality, flatness and symmetry and variation in the output on daily basis. Flatness and symmetry are the main parameters for determining the pattern of a photon and electron beam produced by linear accelerators. The quality assurance in routine clinical practice of radiotherapy and consequently the treatment-outcome depends definitely on the physical parameters of treatment-delivery. Several recommendations from national and international associations are reported to define the limits for the beam parameters. The review of literature and various reports on quality assurance in radiotherapy show that for flatness, symmetry and output constancy the optimal level of deviation should be within ±3%

  11. Probabilistic safety assessment of the radiotherapy treatment with a linear accelerator for medical use

    International Nuclear Information System (INIS)

    Vilaragut Llanes, Juan Jose; Ferro Fernandez, Ruben; Rodriguez MartI, Manuel; Ramirez, Maria Luisa; Perez Mulas, Arturo; Barrientos Montero, Marta; Ortiz Lopez, Pedro; Somoano, Fernando; Delgado RodrIguez, Jose Miguel; Papadopulos, Susana B.; Pereira Jr, Pedro Paulo; Lopez Morones, Ramon; Larrinaga Cortina, Eduardo; Rivero Oliva, Jose de Jesus; Alemanny, Jorge

    2010-01-01

    This paper presents the results of the Probabilistic Safety Assessment to the radiotherapy treatment with an Electron Linear Accelerator for Medical Use, which was conducted in the framework of the Iberian-American Forum of Radiological and Nuclear Regulatory Agencies. Potential accidental exposures during the treatment of patients, workers and members of the public were assessed, although the study was mainly focused on patients. The methodology of failure modes and effects analysis was used to define accident initiating events and methods of event tree and fault tree analysis to determine the accident sequences that may occur. After quantifying the frequency of occurrence of the accident sequences, an important analysis was carried out in order to determine the most significant events from the point of view of safety. The major contributors to risk were identified as well as the most appropriate safety recommendations to reduce it. (author)

  12. Status report on electron cyclotron resonance ion sources at the Heavy Ion Medical Accelerator in Chiba

    CERN Document Server

    Kitagawa, A; Sekiguchi, M; Yamada, S; Jincho, K; Okada, T; Yamamoto, M; Hattori, T G; Biri, S; Baskaran, R; Sakata, T; Sawada, K; Uno, K

    2000-01-01

    The Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences (NIRS) is not only dedicated to cancer therapy, it is also utilized with various ion species for basic experiments of biomedical science, physics, chemistry, etc. Two electron cyclotron resonance (ECR) ion sources are installed for production of gaseous ions. One of them, the NIRS-ECR, is a 10 GHz ECR ion source, and is mainly operated to produce C/sup 4+/ ions for daily clinical treatment. This source realizes good reproducibility and reliability and it is easily operated. The other source, the NIRS-HEC, is an 18 GHz ECR ion source that is expected to produce heavier ion species. The output ion currents of the NIRS-ECR and the NIRS-HEC are 430e mu A for C/sup 4+/ and 1.1e mA for Ar/sup 8+/, respectively. (14 refs).

  13. Neutron dose to patients treated with high-energy medical accelerators

    International Nuclear Information System (INIS)

    McGinley, P.H.

    2001-01-01

    The neutron dose equivalent received by patients treated with high energy x-ray beams was measured in this research. A total of 13 different medical accelerators were evaluated in terms of the neutron dose equivalent in the patient plane and at the beam center. The neutron dose equivalent at the beam center was found to ranged from 0.02 to 9.4 mSv per Sv of x-ray dose and values from 0.029 to 2.58 mSv per Sv of x-ray were measured in the patient plane. It was concluded that the neutron levels meet the International Electrotechnical Commission standard for the patient plane. It was also concluded that when intensity modulated radiation treatment is conducted the neutron dose equivalent received by the patient will increase by a factor of 2 to 10. (author)

  14. Experimental validation of neutron activation simulation of a varian medical linear accelerator.

    Science.gov (United States)

    Morato, S; Juste, B; Miro, R; Verdu, G; Diez, S

    2016-08-01

    This work presents a Monte Carlo simulation using the last version of MCNP, v. 6.1.1, of a Varian CLinAc emitting a 15MeV photon beam. The main objective of the work is to estimate the photoneutron production and activated products inside the medical linear accelerator head. To that, the Varian LinAc head was modelled in detail using the manufacturer information, and the model was generated with a CAD software and exported as a mesh to be included in the particle transport simulation. The model includes the transport of photoneutrons generated by primary photons and the (n, γ) reactions which can result in activation products. The validation of this study was done using experimental measures. Activation products have been identified by in situ gamma spectroscopy placed at the jaws exit of the LinAc shortly after termination of a high energy photon beam irradiation. Comparison between experimental and simulation results shows good agreement.

  15. Photoneutrons from medical linear accelerators--radiobiological measurements and risk estimates

    International Nuclear Information System (INIS)

    Hall, Eric J.; Martin, Stewart G.; Amols, Howard; Hei, Tom K.

    1995-01-01

    Purpose: To assess the oncogenic potential of the photoneutrons produced by high energy medical linear accelerators. Methods and Materials: An established line of cells of rodent origin (C 3 H 10T1/2) was used to assess the oncogenic potential of the radiation dose received in the breast of an anthropomorphic 'randoman' phanton, while the cervix received a dose of 70 Gy. Experiments were performed at 6 MV, below the threshold for the production of photoneutrons, and at 20 MV where the dose includes about 0.01 Gy of photoneutrons as well as scattered x-rays. Results: A significantly higher transformation incidence was observed for the 20-MV machine, consistent with the measured neutron dose of about 0.01 Gy and a quality factor of 20. Conclusion: An estimate can be made of the additional deaths from second malignancies that might result from the photoneutrons generated by higher energy linear accelerators (Linacs), which must be offset against the possible improvements in survival that might result from the higher tumor doses made possible by the increased percentage depth doses

  16. An MCNP-based model of a medical linear accelerator x-ray photon beam.

    Science.gov (United States)

    Ajaj, F A; Ghassal, N M

    2003-09-01

    The major components in the x-ray photon beam path of the treatment head of the VARIAN Clinac 2300 EX medical linear accelerator were modeled and simulated using the Monte Carlo N-Particle radiation transport computer code (MCNP). Simulated components include x-ray target, primary conical collimator, x-ray beam flattening filter and secondary collimators. X-ray photon energy spectra and angular distributions were calculated using the model. The x-ray beam emerging from the secondary collimators were scored by considering the total x-ray spectra from the target as the source of x-rays at the target position. The depth dose distribution and dose profiles at different depths and field sizes have been calculated at a nominal operating potential of 6 MV and found to be within acceptable limits. It is concluded that accurate specification of the component dimensions, composition and nominal accelerating potential gives a good assessment of the x-ray energy spectra.

  17. An investigation of the efficiency in simulating 6 MV medical accelerator using OMEGA/BEAM

    International Nuclear Information System (INIS)

    Dai Zhenhui; Wang Xuetao; Zhu Lin; Zhang Yu; Liu Xiaowei

    2013-01-01

    Background: Monte Carlo simulation techniques are presently considered to be the most reliable method for radiation therapy treatment planning. However, long simulation times involved when using the general-purpose Monte Carlo code systems have led to the development of special-purpose Monte Carlo programs. Purpose: This paper attempts to improve computing efficiency for dose calculation in the EGSnrc modeling of clinical linear accelerator by selecting proper parameters. Methods: Several variance reduction techniques including uniform bremsstrahlung splitting, selective bremsstrahlung splitting, directional bremsstrahlung splitting are applied in BEAMnrc simulating medical accelerator treatment head to generate phase-space file which is selected as a source for DOSXYZnrc simulation, both photon splitting and particle recycling are used to improve the efficiency in the calculation of dose profile in water phantom. Results: The splitting number for maximum efficiency in directional bremsstrahlung splitting (no electron splitting) is 2500 in the BEAMnrc simulation. The highest efficiency of DOSXYZnrc simulation is given when photon splitting number is set to 40. Conclusions: Efficiency can be significantly improved by setting appropriate bremsstrahlung splitting and optimized photon splitting number and particle recycling number. (authors)

  18. Retrospective Chart Review of Skin-to-Skin Contact in the Operating Room and Administration of Analgesic and Anxiolytic Medication to Women After Cesarean Birth.

    Science.gov (United States)

    Wagner, Debra L; Lawrence, Stephen; Xu, Jing; Melsom, Janice

    2018-04-01

    Transporting a newborn out of the operating room after cesarean birth can contribute to maternal awareness of discomfort, anxiety, and the need for administration of analgesics and anxiolytics for relief. This retrospective study analyzed the association between skin-to-skin contact in the operating room and administration of analgesics and anxiolytics to women in the operating and recovery rooms after cesarean birth. Our results indicated a trend toward decreased medication administration for women who experienced skin-to-skin contact and add to evidence supporting the incorporation of skin-to-skin contact in the operating room as the standard of care for cesarean birth. This practice has the potential to enhance the birth experience, promote breastfeeding, and provide greater safety with less exposure to opioids and benzodiazepines for women and their newborns. © 2018 AWHONN, the Association of Women’s Health, Obstetric and Neonatal Nurses.

  19. INVESTIGATION OF SECONDARY MIXED RADIATION FIELD AROUND A MEDICAL LINEAR ACCELERATOR.

    Science.gov (United States)

    Tulik, Piotr; Tulik, Monika; Maciak, Maciej; Golnik, Natalia; Kabat, Damian; Byrski, Tomasz; Lesiak, Jan

    2017-09-29

    The aim of this study is to investigate secondary mixed radiation field around linac, as the first part of an overall assessment of out-of-field contribution of neutron dose for new advanced radiation dose delivery techniques. All measurements were performed around Varian Clinic 2300 C/D accelerator at Maria Sklodowska-Curie Memorial, Cancer Center and Institute of Oncology, Krakow Branch. Recombination chambers REM-2 and GW2 were used for recombination index of radiation quality Q4 determination (as an estimate of quality factor Q), measurement of total tissue dose Dt and calculation of gamma and neutron components to Dt. Estimation of Dt and Q4 allowed for the ambient dose equivalent H*(10) per monitor unit (MU) calculations. Measurements around linac were performed on the height of the middle of the linac's head (three positions) and on the height of the linac's isocentre (five positions). Estimation of secondary radiation level was carried out for seven different configurations of upper and lower jaws position and multileaf collimator set open or closed in each position. Study includes the use of two photon beam modes: 6 and 18 MV. Spatial distribution of ambient dose equivalent H*(10) per MU on the height of the linac's head and on the standard couch height for patients during the routine treatment, as well as relative contribution of gamma and neutron secondary radiation inside treatment room were evaluated. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Epidemiological profile of work-related accidents with biological exposure among medical students in a surgical emergency room.

    Science.gov (United States)

    Reis, Phillipe Geraldo Teixeira de Abreu; Driessen, Anna Luiza; da Costa, Ana Claudia Brenner Affonso; Nasr, Adonis; Collaço, Iwan Augusto; Tomasich, Flávio Daniel Saavedra

    2013-01-01

    To evaluate the accidents with biological material among medical students interning in a trauma emergency room and identify key related situations, attributed causes and prevention. we conducted a study with a quantitative approach. Data were collected through a questionnaire applied via internet, with closed, multiple-choice questions regarding accidents with biological material. The sample comprised 100 students. thirty-two had accidents with biological material. Higher-risk activities were local anesthesia (39.47%), suture (18.42%) and needle recapping (15.79%). The main routes of exposure to biological material were the eyes or mucosa, with 34%, and syringe needle puncture, with 45%. After contamination, only 52% reported the accident to the responsible department. The main causes of accidents and routes of exposure found may be attributed to several factors, such as lack of training and failure to use personal protective equipment. Educational and preventive actions are extremely important to reduce the incidence of accidents with biological materials and improve the conduct of post-exposure. It is important to understand the main causes attributed and situations related, so as general and effective measures can be applied.

  1. Do radio frequencies of medical instruments common in the operating room interfere with near-infrared spectroscopy signals?

    Science.gov (United States)

    Shadgan, Babak; Molavi, Behnam; Reid, W. D.; Dumont, Guy; Macnab, Andrew J.

    2010-02-01

    Background: Medical and diagnostic applications of near infrared spectroscopy (NIRS) are increasing, especially in operating rooms (OR). Since NIRS is an optical technique, radio frequency (RF) interference from other instruments is unlikely to affect the raw optical data, however, NIRS data processing and signal output could be affected. Methods: We investigated the potential for three common OR instruments: an electrical cautery, an orthopaedic drill and an imaging system, to generate electromagnetic interference (EMI) that could potentially influence NIRS signals. The time of onset and duration of every operation of each device was recorded during surgery. To remove the effects of slow changing physiological variables, we first used a lowpass filter and then selected 2 windows with variable lengths around the moment of device onset. For each instant, variances (energy) and means of the signals in the 2 windows were compared. Results: Twenty patients were studied during ankle surgery. Analysis shows no statistically significant difference in the means and variance of the NIRS signals (p < 0.01) during operation of any of the three devices for all surgeries. Conclusion: This method confirms the instruments evaluated caused no significant interference. NIRS can potentially be used without EMI in clinical environments such as the OR.

  2. Decontamination of the activation product based on a legal revision of the cyclotron vault room on the non-self-shield compact medical cyclotron

    International Nuclear Information System (INIS)

    Komiya, Isao; Umezu, Yoshiyuki; Fujibuchi, Toshiou; Nakamura, Kazumasa; Baba, Shingo; Honda, Hiroshi

    2016-01-01

    The non-self-shield compact medical cyclotron and the cyclotron vault room were in operation for 27 years. They have now been decommissioned. We efficiently implemented a technique to identify an activation product in the cyclotron vault room. Firstly, the distribution of radioactive concentrations in the concrete of the cyclotron vault room was estimated by calculation from the record of the cyclotron operation. Secondly, the comparison of calculated results with an actual measurement was performed using a NaI scintillation survey meter and a high-purity germanium detector. The calculated values were overestimated as compared to the values measured using the Nal scintillation survey meter and the high-purity germanium detector. However, it could limit the decontamination area. By simulating the activation range, we were able to minimize the concrete core sampling. Finally, the appropriate range of radioactivated area in the cyclotron vault room was decontaminated based on the results of the calculation. After decontamination, the radioactive concentration was below the detection limit value in all areas inside the cyclotron vault room. By these procedures, the decommissioning process of the cyclotron vault room was more efficiently performed. (author)

  3. Radiation protection studies for medical particle accelerators using FLUKA Monte Carlo code

    International Nuclear Information System (INIS)

    Infantino, Angelo; Mostacci, Domiziano; Cicoria, Gianfranco; Lucconi, Giulia; Pancaldi, Davide; Vichi, Sara; Zagni, Federico; Marengo, Mario

    2017-01-01

    Radiation protection (RP) in the use of medical cyclotrons involves many aspects both in the routine use and for the decommissioning of a site. Guidelines for site planning and installation, as well as for RP assessment, are given in international documents; however, the latter typically offer analytic methods of calculation of shielding and materials activation, in approximate or idealised geometry set-ups. The availability of Monte Carlo (MC) codes with accurate up-to-date libraries for transport and interaction of neutrons and charged particles at energies below 250 MeV, together with the continuously increasing power of modern computers, makes the systematic use of simulations with realistic geometries possible, yielding equipment and site-specific evaluation of the source terms, shielding requirements and all quantities relevant to RP at the same time. In this work, the well-known FLUKA MC code was used to simulate different aspects of RP in the use of biomedical accelerators, particularly for the production of medical radioisotopes. In the context of the Young Professionals Award, held at the IRPA 14 conference, only a part of the complete work is presented. In particular, the simulation of the GE PETtrace cyclotron (16.5 MeV) installed at S. Orsola-Malpighi University Hospital evaluated the effective dose distribution around the equipment; the effective number of neutrons produced per incident proton and their spectral distribution; the activation of the structure of the cyclotron and the vault walls; the activation of the ambient air, in particular the production of "4"1Ar. The simulations were validated, in terms of physical and transport parameters to be used at the energy range of interest, through an extensive measurement campaign of the neutron environmental dose equivalent using a rem-counter and TLD dosemeters. The validated model was then used in the design and the licensing request of a new Positron Emission Tomography facility. (authors)

  4. Introducing a system for automated control of rotation axes, collimator and laser adjustment for a medical linear accelerator

    International Nuclear Information System (INIS)

    Winkler, Peter; Bergmann, Helmar; Stuecklschweiger, Georg; Guss, Helmuth

    2003-01-01

    Mechanical stability and precise adjustment of rotation axes, collimator and room lasers are essential for the success of radiotherapy and particularly stereotactic radiosurgery with a linear accelerator. Quality assurance procedures, at present mainly based on visual tests and radiographic film evaluations, should desirably be little time consuming and highly accurate. We present a method based on segmentation and analysis of digital images acquired with an electronic portal imaging device (EPID) that meets these objectives. The method can be employed for routine quality assurance with a square field formed by the built-in collimator jaws as well as with a circular field using an external drill hole collimator. A number of tests, performed to evaluate accuracy and reproducibility of the algorithm, yielded very satisfying results. Studies performed over a period of 18 months prove the applicability of the inspected accelerator for stereotactic radiosurgery

  5. Maintenance of a medical klystron linear accelerator and evaluation of the lifetime of the klystron

    International Nuclear Information System (INIS)

    Yokoyama, Koichi; Takita, Takenobu; Hashimoto, Shigeo; Koda, Yukio; Sawayanagi, Hisayoshi

    1981-01-01

    A 15 MeV Mitsubishi medical linear accelerator was installed at our center in June 1971. Clinical use and maintenance of the machine are reviewed. Special attention should be paid to the fact that only one klystron tube has been working for nine years. This tube has now recorded more than 17,000 filament hours, while the manufacturer's warranty time is 1,500 hours. Extension of the operating hours will significantly reduce the maintenance expenses of the machine. In this aspect, we intended to evaluate the lifetime of the Mitsubishi klystron used at several hospitals by means of a questionnaire. As a result, the following points are noticed: 1. It is advisable to keep in use a klystron tube which has been working normally for a quite long time. (Preventive replacement is unnecessary.) 2. A protective device should be provided to prevent the trouble which will follow the breakage in a klystron. 3. The present warranty time for the klystron may depend on the lifetime of individual products, including even some defective ones. If the occurrence of such products is minimized, the mean life of the klystron will be extended considerably and, consequently, the warranty time can also be prolonged to a great extent. (author)

  6. Developments in the design of proton and ion accelerators for medical use

    CERN Document Server

    Bryant, P J

    1998-01-01

    Accelerators and medicine have been close companions since cyclotrons first made biological studies with particle beams possible in the 1930s. Later improvements, such as H-minus (H-) extraction, made cyclotrons the foremost, commercially-available producer of medical isotopes. Although the world's first hospital-based proton treatment centre, Loma Linda, uses a synchrotron, the cyclotron is now al so establishing a dominance in proton centres using passive beam spreading. However, two trends indicate a slightly different direction. The first is towards light ions and the second is towards 'penc il' beam scanning with active energy control. Together, these point to a new generation of synchrotrons with slow-beam-extraction systems that allow time for on-line dosimetry and provide very smooth spills. There are several variants for the slow extraction including the use of a betatron core and rf knockout. There are also methods for improving the spill quality such as rf channelling buckets a nd rf noise. The use...

  7. Management of activated parts generated during the dismantling of linear accelerators for medical uses

    International Nuclear Information System (INIS)

    Ortiz, Teresa; Correa, Cristina

    2008-01-01

    During years 2006-2008 have been carried out to the dismantling of several linear accelerators of medical use in Spain. The two first were in the Hospital of 'La Princesa' in Madrid and in the Hospital 'Santa Creu y Sant Pau' in Barcelona. The disassembling of such was made by technicians of the providing company and of the own hospital, with the advising of experts of the Radiological Protection and Radiophysics Service of such. Technicians of the Radiological Protection Technical Unit (RPU) of ENRESA collaborated in these dismantlings with the objective to determine that pieces could be evacuated conventionally as metallic scraps and which had to be managed as radioactive waste. In the following dismantling the classification of the pieces were carried out by the technicians of the providing company. After that the technicians of the RPU of ENRESA verified this classification and characterized, in detail, the pieces classified as radioactive wasted before their removal. In this paper the activities carried out to classify the pieces and the legal bases in which it leans on, as well as the measures made for the characterization of the materials considered as radioactive waste are described. (author)

  8. Effects of Field Distortions in IH-APF Linac for a Compact Medical Accelerator

    CERN Document Server

    Kapin, Valery; Yamada, Satoru

    2004-01-01

    The project on developing compact medical accelerators for the tumor therapy using carbon ions has been started at the National Institute of Radiological Sciences (NIRS). Alternating-phase-focused (APF) linac using an interdigital H-mode (IH) cavity has been proposed for the injector linac. The IH-cavity is a doubly ridged circular resonator loaded by the drift-tubes mounted on ridges with supporting stems. The effects of intrinsic and random field distortions in a practical design of the 4-Mev/u 200-MHz IH-APF linac are considered. The intrinsic field distortions in the IH-cavity are caused by an asymmetry of the gap fields due to presence of the stems and pair of ridges. The random field distortions are caused by drift-tube misalignments and non-regular deviations of the gap voltages from programmed values. The RF fields in the IH-cavity have been calculated using Microwave Studio (MWS) code. The effects of field distortions on beam dynamics have been simulated numerically. The intrinsic field distortions a...

  9. Beam Characterization of 10-MV Photon Beam from Medical Linear Accelerator without Flattening Filter.

    Science.gov (United States)

    Shimozato, Tomohiro; Aoyama, Yuichi; Matsunaga, Takuma; Tabushi, Katsuyoshi

    2017-01-01

    This work investigated the dosimetric properties of a 10-MV photon beam emitted from a medical linear accelerator (linac) with no flattening filter (FF). The aim of this study is to analyze the radiation fluence and energy emitted from the flattening filter free (FFF) linac using Monte Carlo (MC) simulations. The FFF linac was created by removing the FF from a linac in clinical use. Measurements of the depth dose (DD) and the off-axis profile were performed using a three-dimensional water phantom with an ionization chamber. A MC simulation for a 10-MV photon beam from this FFF linac was performed using the BEAMnrc code. The off-axis profiles for the FFF linac exhibited a chevron-like distribution, and the dose outside the irradiation field was found to be lower for the FFF linac than for a linac with an FF (FF linac). The DD curves for the FFF linac included many contaminant electrons in the build-up region. Therefore, for clinical use, a metal filter is additionally required to reduce the effects of the electron contamination. The mean energy of the FFF linac was found to be lower than that of the FF linac owing to the absence of beam hardening caused by the FF.

  10. The present status of medical application of particle accelerator. Started construction of a new medically dedicated proton accelerator facility in Tsukuba

    International Nuclear Information System (INIS)

    Sakae, Takeji; Maruhashi, Akira

    1999-01-01

    A new facility of PMRC starts the construction in the neighborhood of Tsukuba university hospital, in order to establish technical skill for practical use in the cancer treatment and to grope for new skill. The facility has a linac injection system, a compact synchrotron, two rotating gantry rooms and two fixed horizontal beam lines. The outline of the design arranged for the facility is reviewed. As one of the important technique for the treatment, investigation into target adjusting accuracy in respiration-gated proton irradiation is presented. (author)

  11. QALMA: A computational toolkit for the analysis of quality protocols for medical linear accelerators in radiation therapy

    Science.gov (United States)

    Rahman, Md Mushfiqur; Lei, Yu; Kalantzis, Georgios

    2018-01-01

    Quality Assurance (QA) for medical linear accelerator (linac) is one of the primary concerns in external beam radiation Therapy. Continued advancements in clinical accelerators and computer control technology make the QA procedures more complex and time consuming which often, adequate software accompanied with specific phantoms is required. To ameliorate that matter, we introduce QALMA (Quality Assurance for Linac with MATLAB), a MALAB toolkit which aims to simplify the quantitative analysis of QA for linac which includes Star-Shot analysis, Picket Fence test, Winston-Lutz test, Multileaf Collimator (MLC) log file analysis and verification of light & radiation field coincidence test.

  12. Medical research and multidisciplinary applications with laser-accelerated beams: the ELIMED netwotk at ELI-Beamlines

    Science.gov (United States)

    Tramontana, A.; Anzalone, A.; Candiano, G.; Carpinelli, M.; Cirrone, G. A. P.; Cuttone, G.; Korn, G.; Licciardello, T.; Maggiore, M.; Manti, L.; Margarone, D.; Musumarra, A.; Perozziello, F.; Pisciotta, P.; Raffaele, L.; Romano, F.; Romano, F. P.; Stancampiano, C.; Schillaci, F.; Scuderi, V.; Torrisi, L.; Tudisco, S.

    2014-04-01

    Laser accelerated proton beams represent nowadays an attractive alternative to the conventional ones and they have been proposed in different research fields. In particular, the interest has been focused in the possibility of replacing conventional accelerating machines with laser-based accelerators in order to develop a new concept of hadrontherapy facilities, which could result more compact and less expensive. With this background the ELIMED (ELIMED: ELI-Beamlines MEDical applications) research project has been launched by LNS-INFN researchers (Laboratori Nazionali del Sud-Istituto Nazionale di Fisica Nucleare, Catania, IT) and ASCR-FZU researchers (Academy of Sciences of the Czech Republic-Fyzikální ústar, Prague, Cz), within the pan-European ELI-Beamlines facility framework. Its main purposes are the demonstration of future applications in hadrontherapy of optically accelerated protons and the realization of a laser-accelerated ion transport beamline for multidisciplinary applications. Several challenges, starting from laser-target interaction and beam transport development, up to dosimetric and radiobiological issues, need to be overcome in order to reach the final goals. The design and the realization of a preliminary beam handling and dosimetric system and of an advanced spectrometer for high energy (multi-MeV) laser-accelerated ion beams will be shortly presented in this work.

  13. An MCNP-based model for the evaluation of the photoneutron dose in high energy medical electron accelerators.

    Science.gov (United States)

    Carinou, Eleutheria; Stamatelatos, Ion Evangelos; Kamenopoulou, Vassiliki; Georgolopoulou, Paraskevi; Sandilos, Panayotis

    The development of a computational model for the treatment head of a medical electron accelerator (Elekta/Philips SL-18) by the Monte Carlo code mcnp-4C2 is discussed. The model includes the major components of the accelerator head and a pmma phantom representing the patient body. Calculations were performed for a 14 MeV electron beam impinging on the accelerator target and a 10 cmx10 cm beam area at the isocentre. The model was used in order to predict the neutron ambient dose equivalent at the isocentre level and moreover the neutron absorbed dose distribution within the phantom. Calculations were validated against experimental measurements performed by gold foil activation detectors. The results of this study indicated that the equivalent dose at tissues or organs adjacent to the treatment field due to photoneutrons could be up to 10% of the total peripheral dose, for the specific accelerator characteristics examined. Therefore, photoneutrons should be taken into account when accurate dose calculations are required to sensitive tissues that are adjacent to the therapeutic X-ray beam. The method described can be extended to other accelerators and collimation configurations as well, upon specification of treatment head component dimensions, composition and nominal accelerating potential.

  14. Application of Electron Accelerators in Conjunction with Microwave Sources in Medical Studies

    International Nuclear Information System (INIS)

    Martin, D.; Craciun, G.; Manaila, E.; Ighigeanu, D.; Margaritescu, I.; Chirita, D.; Neagu, M.

    2009-01-01

    Electron beams (EB) are presently used, in addition to the routine conventional radiotherapy techniques, for cancer specialized therapies (intensity modulated radiation therapy [1] and total body electron irradiation [2]), the irradiation of blood and blood components, vaccine preparation, and other. Microwaves (MW) are presently used for therapeutic applications in cardiology, urology, surgery, ophthalmology, cancer therapy, and others, and for diagnostic applications such as cancer detection, organ imaging, and more [3]. The reported data show that low dose-all body irradiation with ionizing as well as with nonionizing irradiation may enhance the tumoricidal effects of radiation or chemotherapy, overcome acquired drug resistance and can stimulate certain components of the immune system that may aid in destroying cancer cells. These data suggested that application of low-dose total body EB + MW irradiation in conjunction with chemotherapy could contribute by novel effects to the cancer therapies. In view of this argument two specifically designed radiation exposure devices (REDs) were carried out for separate, successive and simultaneous irradiation with EB of 6.23 MeV and MW of 2.45 GHz in vivo (RED-vivo) and in vitro (RED-vitro) for the following medical studies: 1) The effects of low-dose EB + MW total body irradiation without/with drugs administration on the C57 BL/6 mice bearing malignant melanoma (MM); 2) The effects of separate and simultaneous MW and EB irradiation on MM cells culture without/with drugs incubation and on human blood components (proteins and cells) irradiated in samples of integral blood from healthy donors and from donors with MM. Both REDs consist of the following units: 1) An accelerated EB source: ALIN-10 electron linear accelerator of 6.23 MeV and adjustable absorbed dose rate from 0.002 Gy s-1 up to 70 Gy s-1 (built in the NILPRP, Bucharest, Romania); 2) A special designed exposure chamber that permits inside separate, successive or

  15. Measurement of activity distribution using photostimulable phosphor imaging plates in decommissioned 10 MV medical linear accelerator.

    Science.gov (United States)

    Fujibuchi, Toshioh; Yonai, Shunsuke; Yoshida, Masahiro; Sakae, Takeji; Watanabe, Hiroshi; Abe, Yoshihisa; Itami, Jun

    2014-08-01

    Photonuclear reactions generate neutrons in the head of the linear accelerator. Therefore, some parts of the linear accelerator can become activated. Such activated materials must be handled as radioactive waste. The authors attempted to investigate the distribution of induced radioactivity using photostimulable phosphor imaging plates. Autoradiographs were produced from some parts of the linear accelerator (the target, upper jaw, multileaf collimator and shielding). The levels of induced radioactivity were confirmed to be non-uniform within each part from the autoradiographs. The method was a simple and highly sensitive approach to evaluating the relative degree of activation of the linear accelerators, so that appropriate materials management procedures can be carried out.

  16. Air quality monitoring of the post-operative recovery room and locations surrounding operating theaters in a medical center in Taiwan.

    Directory of Open Access Journals (Sweden)

    Chin-Sheng Tang

    Full Text Available To prevent surgical site infection (SSI, the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH, and carbon dioxide (CO2, suspended particulate matter (PM, and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18% and traumatic surgery room (8%. The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.

  17. Air quality monitoring of the post-operative recovery room and locations surrounding operating theaters in a medical center in Taiwan.

    Science.gov (United States)

    Tang, Chin-Sheng; Wan, Gwo-Hwa

    2013-01-01

    To prevent surgical site infection (SSI), the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH), and carbon dioxide (CO2), suspended particulate matter (PM), and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18%) and traumatic surgery room (8%). The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.

  18. Monte Carlo simulation of a medical accelerator: application on a heterogeneous phantom

    International Nuclear Information System (INIS)

    Serrano, B.; Franchisseur, E.; Hachem, A.; Herault, J.; Marcie, S.; Bensadoun, R.J.

    2005-01-01

    The objective of this study is to seek an accurate and efficient method to calculate the dose distribution for small fields in high gradient heterogeneity, typical for Intensity Modulated Radiation Therapy (IMRT) technique on head and neck regions. This motivates a Monte Carlo (MC) simulation of the photon beam for the two nominal potential energies of 25 and 6 MV delivered by a medical linear electron accelerator (Linac) used at the Centre Antoine Lacassagne. These investigations were checked by means of an ionization chamber (IC). Some first adjustments on parameters given by the manufacturer for the 25 and the 6 MV data have been applied to optimize the adjustment between the IC and the MC simulation on the depth-dose and the dose profile distributions. The good agreement between the MC calculated and the measured data are only obtained when the mean energies of the electron beams are respectively 15 MeV and 5.2 MeV and the corresponding spot size diameter 2 and 3 mm. Once the validation of the MC simulation of the Linac is overcome, these results permit us in a second part to check the calculation data given by a treatment planning system (TPS) on a heterogeneous phantom. The result shows some discrepancies up to 7% between TPS and MC simulation. Those differences come from a bad approximation of the material density by the TPS. These encouraging results of the MC simulation will permit us afterwards to check the dose deposition given by the TPS on IMRT treatment. (authors)

  19. Treatment vault shielding for a flattening filter-free medical linear accelerator

    Science.gov (United States)

    Kry, Stephen F.; Howell, Rebecca M.; Polf, Jerimy; Mohan, Radhe; Vassiliev, Oleg N.

    2009-03-01

    The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target current requirements were determined from treatment planning studies of several disease sites with, and without, the flattening filter. The flattened beam shielding data were compared to data published in NCRP Report No. 151, and the unflattened beam shielding data were presented relative to the NCRP data. Finally, the shielding requirements for a typical treatment vault were determined for a single-energy (6 MV) linac and a dual-energy (6 MV/18 MV) linac. With the exception of large-angle patient scatter fractions and wall scatter fractions, the vault shielding parameters were reduced when the flattening filter was removed. Much of this reduction was consistent with the reduced average energy of the FFF beams. Primary beam TVLs were reduced by 12%, on average, and small-angle scatter fractions were reduced by up to 30%. Head leakage was markedly reduced because less integral target current was required to deliver the target dose. For the treatment vault examined in the current study, removal of the flattening filter reduced the required thickness of the primary and secondary barriers by 10-20%, corresponding to 18 m3 less concrete to shield the single-energy linac and 36 m3 less concrete to shield the dual-energy linac. Thus, a shielding advantage was found when the linac was operated without the flattening filter. This translates into a reduction in occupational exposure and/or the cost and space of shielding.

  20. Treatment vault shielding for a flattening filter-free medical linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kry, Stephen F; Howell, Rebecca M; Polf, Jerimy; Mohan, Radhe; Vassiliev, Oleg N [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States)], E-mail: sfkry@mdanderson.org

    2009-03-07

    The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target current requirements were determined from treatment planning studies of several disease sites with, and without, the flattening filter. The flattened beam shielding data were compared to data published in NCRP Report No. 151, and the unflattened beam shielding data were presented relative to the NCRP data. Finally, the shielding requirements for a typical treatment vault were determined for a single-energy (6 MV) linac and a dual-energy (6 MV/18 MV) linac. With the exception of large-angle patient scatter fractions and wall scatter fractions, the vault shielding parameters were reduced when the flattening filter was removed. Much of this reduction was consistent with the reduced average energy of the FFF beams. Primary beam TVLs were reduced by 12%, on average, and small-angle scatter fractions were reduced by up to 30%. Head leakage was markedly reduced because less integral target current was required to deliver the target dose. For the treatment vault examined in the current study, removal of the flattening filter reduced the required thickness of the primary and secondary barriers by 10-20%, corresponding to 18 m{sup 3} less concrete to shield the single-energy linac and 36 m{sup 3} less concrete to shield the dual-energy linac. Thus, a shielding advantage was found when the linac was operated without the flattening filter. This translates into a reduction in occupational exposure and/or the cost and space of shielding.

  1. Treatment vault shielding for a flattening filter-free medical linear accelerator

    International Nuclear Information System (INIS)

    Kry, Stephen F; Howell, Rebecca M; Polf, Jerimy; Mohan, Radhe; Vassiliev, Oleg N

    2009-01-01

    The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target current requirements were determined from treatment planning studies of several disease sites with, and without, the flattening filter. The flattened beam shielding data were compared to data published in NCRP Report No. 151, and the unflattened beam shielding data were presented relative to the NCRP data. Finally, the shielding requirements for a typical treatment vault were determined for a single-energy (6 MV) linac and a dual-energy (6 MV/18 MV) linac. With the exception of large-angle patient scatter fractions and wall scatter fractions, the vault shielding parameters were reduced when the flattening filter was removed. Much of this reduction was consistent with the reduced average energy of the FFF beams. Primary beam TVLs were reduced by 12%, on average, and small-angle scatter fractions were reduced by up to 30%. Head leakage was markedly reduced because less integral target current was required to deliver the target dose. For the treatment vault examined in the current study, removal of the flattening filter reduced the required thickness of the primary and secondary barriers by 10-20%, corresponding to 18 m 3 less concrete to shield the single-energy linac and 36 m 3 less concrete to shield the dual-energy linac. Thus, a shielding advantage was found when the linac was operated without the flattening filter. This translates into a reduction in occupational exposure and/or the cost and space of shielding.

  2. Cobalt-60 Machines and Medical Linear Accelerators: Competing Technologies for External Beam Radiotherapy.

    Science.gov (United States)

    Healy, B J; van der Merwe, D; Christaki, K E; Meghzifene, A

    2017-02-01

    Medical linear accelerators (linacs) and cobalt-60 machines are both mature technologies for external beam radiotherapy. A comparison is made between these two technologies in terms of infrastructure and maintenance, dosimetry, shielding requirements, staffing, costs, security, patient throughput and clinical use. Infrastructure and maintenance are more demanding for linacs due to the complex electric componentry. In dosimetry, a higher beam energy, modulated dose rate and smaller focal spot size mean that it is easier to create an optimised treatment with a linac for conformal dose coverage of the tumour while sparing healthy organs at risk. In shielding, the requirements for a concrete bunker are similar for cobalt-60 machines and linacs but extra shielding and protection from neutrons are required for linacs. Staffing levels can be higher for linacs and more staff training is required for linacs. Life cycle costs are higher for linacs, especially multi-energy linacs. Security is more complex for cobalt-60 machines because of the high activity radioactive source. Patient throughput can be affected by source decay for cobalt-60 machines but poor maintenance and breakdowns can severely affect patient throughput for linacs. In clinical use, more complex treatment techniques are easier to achieve with linacs, and the availability of electron beams on high-energy linacs can be useful for certain treatments. In summary, there is no simple answer to the question of the choice of either cobalt-60 machines or linacs for radiotherapy in low- and middle-income countries. In fact a radiotherapy department with a combination of technologies, including orthovoltage X-ray units, may be an option. Local needs, conditions and resources will have to be factored into any decision on technology taking into account the characteristics of both forms of teletherapy, with the primary goal being the sustainability of the radiotherapy service over the useful lifetime of the equipment

  3. High gradient RF test results of S-band and C-band cavities for medical linear accelerators

    Science.gov (United States)

    Degiovanni, A.; Bonomi, R.; Garlasché, M.; Verdú-Andrés, S.; Wegner, R.; Amaldi, U.

    2018-05-01

    TERA Foundation has proposed and designed hadrontherapy facilities based on novel linacs, i.e. high gradient linacs which accelerate either protons or light ions. The overall length of the linac, and therefore its cost, is almost inversely proportional to the average accelerating gradient. With the scope of studying the limiting factors for high gradient operation and to optimize the linac design, TERA, in collaboration with the CLIC Structure Development Group, has conducted a series of high gradient experiments. The main goals were to study the high gradient behavior and to evaluate the maximum gradient reached in 3 and 5.7 GHz structures to direct the design of medical accelerators based on high gradient linacs. This paper summarizes the results of the high power tests of 3.0 and 5.7 GHz single-cell cavities.

  4. Illustrated instructions for mechanical quality assurance of a medical linear accelerator.

    Science.gov (United States)

    Court, Laurence; Wang, He; Aten, David; Brown, Derek; MacGregor, Hannelie; du Toit, Monique; Chi, Melinda; Gao, Song; Yock, Adam; Aristophanous, Michalis; Balter, Peter

    2018-03-03

    The purpose of this study was to develop and test a set of illustrated instructions for effective training for mechanical quality assurance (QA) of medical linear accelerators (linac). Illustrated instructions were created for mechanical QA and underwent several steps of review, testing, and refinement. Eleven testers with no recent QA experience were then recruited from our radiotherapy department (one student, two computational scientists, and eight dosimetrists). This group was selected because they have experience of radiation therapy but no preconceived ideas about how to do QA. The following parameters were progressively decalibrated on a Varian C-series linac: Group A = gantry angle, ceiling laser position, X1 jaw position, couch longitudinal position, physical graticule position (five testers); Group B = Group A + wall laser position, couch lateral and vertical position, collimator angle (three testers); Group C = Group B + couch angle, wall laser angle, and optical distance indicator (three testers). Testers were taught how to use the linac and then used the instructions to try to identify these errors. An experienced physicist observed each session, giving support on machine operation as necessary. Testers were able to follow the instructions. They determined gantry, collimator, and couch angle errors within 0.4°, 0.3°, and 0.9° of the actual changed values, respectively. Laser positions were determined within 1 mm and jaw positions within 2 mm. Couch position errors were determined within 2 mm and 3 mm for lateral/longitudinal and vertical errors, respectively. Accessory-positioning errors were determined within 1 mm. Optical distance indicator errors were determined within 2 mm when comparing with distance sticks and 6 mm when using blocks, indicating that distance sticks should be the preferred approach for inexperienced staff. Inexperienced users were able to follow these instructions and catch errors within the criteria suggested

  5. AN IMPACT OF THE EFFICIENT FUNCTIONING OF THE VENTILATION AND AIR-CONDITIONING SYSTEM ON THERMAL COMFORT OF THE MEDICAL STAFF IN THE OPERATING ROOM

    Directory of Open Access Journals (Sweden)

    Tomasz Jankowski

    2016-11-01

    Full Text Available Ventilation and air conditioning systems are necessary for developing proper parameters of indoor envi-ronment in operating rooms. The main task of ventilation and air conditioning in those specific areas consists in creating desirable temperature, reducing the number of microorganisms and the concen-trations of hazardous gases and substances in the air, as well as ensuring the proper direction of airflow. In Poland, indoor environment in operating rooms has to comply with the requirements set out in three regulations (Journal of Laws of 2002 No. 75, item 690, as amended, Journal of Laws of 2002 No. 217, item 1833, Journal of Laws of 2011 No. 31, item 158, as amended and the document entitled "Guidelines for the design of general hospitals". Given insufficient accuracy of the abovementioned national documents, it is a common practice to use foreign standards, i.e. ASHRAE Standard 170-2013, DIN 1946-4: 2008 and FprCEN TR 16244: 2011. When considering the conditions for thermal comfort, it is important to bear in mind a close link between air flow velocity and air temperature. Air in the zone occupied by patients and medical staff must not cause the sensation of draft. Furthermore, air velocity should be sufficient to eliminate interference caused by the presence of people and other sources of heat. It should also reduce the turbulence level in the air in the operating room. Efficient functioning of ventilation and air conditioning was tested during treatments and operations carried out on three wards of a Warsaw hospital. Tests were performed with the participation of medical staff from various surgical units. They were asked to perform minor manual tasks to simulate work on the op-erating table, and to complete a questionnaire on subjective thermal sensation. The applied methodology is widely used during testing of general and local ventilation in public buildings. Air temperature, relative humidity, air flow supply and exhaust air from the

  6. Performance of the Operating Room Personnel in following of the standards of Infection Control in the Educational Hospitals of Yasuj University of Medical Sciences in 2009

    Directory of Open Access Journals (Sweden)

    A Rostaminejad

    2011-04-01

    Full Text Available Introduction & Objective: Surgical wound infection is one of the common nosocomial infections. During operation, members of the surgical team which are in contact with the tissue incision should observe the standards of infection control in the operating room since it has a great role in prevention and control of these infections. The present study aimed to determine the performance of the operating room personnel in observing the standards of infection control in educational hospitals of Yasuj University of Medical Sciences in 2009. Materials & Methods: Forty two operating room personnel participated in this cross-sectional analytic-descriptive study. A check list was used for unnoticeably collecting the data about the performance of personnel in respect of infection control standards at three different times. Their performances were classified into four levels (very weak, weak, moderate and good and the results were shown as absolute and relative frequency distribution. Data were analyzed using Chi-square and Fischer exact test by the SPSS software. Results: Performance of personnel in following the standards of infection control in this study was moderate. Conclusion: The results indicate that the participants of the study do not follow some of the standards of infection control in the operating rooms. Therefore, further activities of the committees of infection control and using of new antiseptic for surgical scrub are recommended.

  7. Microwave system of the 7-10 MeV electron linear accelerator ALIN for medical applications

    International Nuclear Information System (INIS)

    Martin, D.; Iliescu, E.; Stirbet, M.; Oproiu, C.; Vintan, I.

    1978-01-01

    A detailed description of the Central Institute of Physics 10 MeV linear microwave system and its associated subsystems are presented. Methods of impedance matching to obtain maximum power transfer are described along with broadband design methods for transmission-line impedance transformers. Experimental results for such microwave devices are included. With respect to microwave device performances, simultaneous high efficiency and high power capability with reliability and long life at relatively low unit cost have only recently been achieved as typical device characteristics. Industrial, medical and scientific application of microwave electron accelerators have markedly influenced microwave research progress. Radiographic linear accelerators have grown substantially mainly during the past few years. Following this, the improvements of microwave device performances solicit our attention. The first electron therapy Linear Accelerator ALIN 10 marks a new stage in the development of such instrumentation. Its subsequent ALIN 15 is designed to produce a maximum energy of 18 MeV to widen its applicability in radiotherapy. In addition, a new electron linear accelerator of 8 MeV for nondestructive testing has been started. (author)

  8. Estimation of neutron production from accelerator head assembly of 15 MV medical LINAC using FLUKA simulations

    Energy Technology Data Exchange (ETDEWEB)

    Patil, B.J., E-mail: bjp@physics.unipune.ac.in [Department of Physics, University of Pune, Pune 411 007 (India); Chavan, S.T., E-mail: sharad@sameer.gov.in [SAMEER, IIT Powai Campus, Mumbai 400 076 (India); Pethe, S.N., E-mail: sanjay@sameer.gov.in [SAMEER, IIT Powai Campus, Mumbai 400 076 (India); Krishnan, R., E-mail: krishnan@sameer.gov.in [SAMEER, IIT Powai Campus, Mumbai 400 076 (India); Bhoraskar, V.N., E-mail: vnb@physics.unipune.ac.in [Department of Physics, University of Pune, Pune 411 007 (India); Dhole, S.D., E-mail: sanjay@physics.unipune.ac.in [Department of Physics, University of Pune, Pune 411 007 (India)

    2011-12-15

    For the production of a clinical 15 MeV photon beam, the design of accelerator head assembly has been optimized using Monte Carlo based FLUKA code. The accelerator head assembly consists of e-{gamma} target, flattening filter, primary collimator and an adjustable rectangular secondary collimator. The accelerators used for radiation therapy generate continuous energy gamma rays called Bremsstrahlung (BR) by impinging high energy electrons on high Z materials. The electron accelerators operating above 10 MeV can result in the production of neutrons, mainly due to photo nuclear reaction ({gamma}, n) induced by high energy photons in the accelerator head materials. These neutrons contaminate the therapeutic beam and give a non-negligible contribution to patient dose. The gamma dose and neutron dose equivalent at the patient plane (SSD = 100 cm) were obtained at different field sizes of 0 Multiplication-Sign 0, 10 Multiplication-Sign 10, 20 Multiplication-Sign 20, 30 Multiplication-Sign 30 and 40 Multiplication-Sign 40 cm{sup 2}, respectively. The maximum neutron dose equivalent is observed near the central axis of 30 Multiplication-Sign 30 cm{sup 2} field size. This is 0.71% of the central axis photon dose rate of 0.34 Gy/min at 1 {mu}A electron beam current.

  9. A dose-per-pulse monitor for a dual-mode medical accelerator

    International Nuclear Information System (INIS)

    Galbraith, D.M.; Martell, E.S.; Fueurstake, T.; Norrlinger, B.; Schwendener, H.; Rawlinson, J.A.

    1990-01-01

    On a radiotherapy accelerator, the dose monitoring system is the last level of protection between the patient and the extremely high dose rate which all accelerators are capable of producing. The risk of losing this level of protection is substantially reduced if two or more dose monitoring systems are used which are mechanically and electrically independent in design. This paper describes the installation of an independent radiation monitor in a dual-mode, computer-controlled accelerator with a moveable monitor chamber. The added device is fixed in the beam path, is capable of monitoring each beam pulse, and is capable of terminating irradiation within the pulse repetition period if any measured pulse is unacceptably high

  10. Monte-Carlo simulation of the SL-ELEKTA-20 medical linear accelerator. Dosimetric study of a water phantom

    International Nuclear Information System (INIS)

    Thiam, Ch. O.

    2003-06-01

    In radiotherapy, it is essential to have a precise knowledge of the dose delivered in the target volume and the neighbouring critical organs. To be usable clinically, the models of calculation must take into account the exact characteristics of the beams used and the densities of fabrics. Today we can use sophisticated irradiation techniques and get a more precise assessment of the dose and with a better knowledge of its distribution. Thus in this report, will be detailed a simulation of the head of irradiation of accelerator SL-ELEKTA-20 in electrons mode and a dosimetric study of a water phantom. This study is carried out with the code of simulation Monte Carlo GATE adapted for applications of medical physics; the results are compared with the data obtained by the anticancer center 'Jean Perrin' on a similar accelerator. (author)

  11. Recent developments of ion sources for life-science studies at the Heavy Ion Medical Accelerator in Chiba (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Kitagawa, A.; Drentje, A. G.; Fujita, T.; Muramatsu, M. [National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555 (Japan); Fukushima, K.; Shiraishi, N.; Suzuki, T.; Takahashi, K.; Takasugi, W. [Accelerator Engineering Corporation, Chiba (Japan); Biri, S.; Rácz, R. [Institute for Nuclear Research (Atomki), Hungarian Academy of Sciences, Bem tér 18/C, H-4026 Debrecen (Hungary); Kato, Y. [Graduate School of Engineering, Osaka University, Osaka (Japan); Uchida, T.; Yoshida, Y. [Bio-Nano Electronics Research Centre, Toyo University, Kawagoe (Japan)

    2016-02-15

    With about 1000-h of relativistic high-energy ion beams provided by Heavy Ion Medical Accelerator in Chiba, about 70 users are performing various biology experiments every year. A rich variety of ion species from hydrogen to xenon ions with a dose rate of several Gy/min is available. Carbon, iron, silicon, helium, neon, argon, hydrogen, and oxygen ions were utilized between 2012 and 2014. Presently, three electron cyclotron resonance ion sources (ECRISs) and one Penning ion source are available. Especially, the two frequency heating techniques have improved the performance of an 18 GHz ECRIS. The results have satisfied most requirements for life-science studies. In addition, this improved performance has realized a feasible solution for similar biology experiments with a hospital-specified accelerator complex.

  12. Biological and medical research with accelerated heavy ions at the Bevalac, 1977-1980

    International Nuclear Information System (INIS)

    Pirruccello, M.C.; Tobias, C.A.

    1980-11-01

    Separate abstracts were prepared for the 46 papers presented in this progress report. This report is a major review of studies with accelerated heavy ions carried out by the Biology and Medicine Division of Lawrence Berkeley Laboratory from 1977 to 1980

  13. Biological and medical research with accelerated heavy ions at the Bevalac, 1977-1980. [Lead abstract

    Energy Technology Data Exchange (ETDEWEB)

    Pirruccello, M.C.; Tobias, C.A. (eds.)

    1980-11-01

    Separate abstracts were prepared for the 46 papers presented in this progress report. This report is a major review of studies with accelerated heavy ions carried out by the Biology and Medicine Division of Lawrence Berkeley Laboratory from 1977 to 1980. (KRM)

  14. Hypoxia Room

    Data.gov (United States)

    Federal Laboratory Consortium — The Hypoxia Room is a 8x8x8 ft. clear vinyl plastic and aluminum frame construction enclosure located within USAREIM laboratory 028. The Hypoxia Room (manufactured...

  15. Evaluation of CdZnTe as neutron detector around medical accelerators

    International Nuclear Information System (INIS)

    Martin-Martin, A.; Iniguez, M. P.; Luke, P. N.; Barquero, R.; Lorente, A.; Morchon, J.; Gallego, E.; Quincoces, G.; Marti-Climent, J. M.

    2009-01-01

    The operation of electron linear accelerators (LINACs) and cyclotrons can produce a mixed gamma-neutron field composed of energetic neutrons coming directly from the source and scattered lower energy neutrons. The thermal neutron detection properties of a non-moderated coplanar-grid CdZnTe (CZT) gamma-ray detector close to an 18 MV electron LINAC and an 18 MeV proton cyclotron producing the radioisotope 18 F for positron emission tomography are investigated. The two accelerators are operated at conditions producing similar thermal neutron fluence rates of the order of 104 cm -2 s -1 at the measurement locations. The counting efficiency of the CZT detector using the prompt 558 keV photopeak following 113 Cd thermal neutron capture is evaluated and a good neutron detection performance is found at the two installations. (authors)

  16. Computer study of isotope production for medical and industrial applications in high power accelerators

    Science.gov (United States)

    Mashnik, S. G.; Wilson, W. B.; Van Riper, K. A.

    2001-07-01

    Methods for radionuclide production calculation in a high power proton accelerator have been developed and applied to study production of 22 isotopes. These methods are readily applicable both to accelerator and reactor environments and to the production of other radioactive and stable isotopes. We have also developed methods for evaluating cross sections from a wide variety of sources into a single cross section set and have produced an evaluated library covering about a third of all natural elements that may be expanded to other reactions. A 684 page detailed report on this study, with 37 tables and 264 color figures, is available on the Web at http://t2.lanl.gov/publications/.

  17. A computer study of radionuclide production in high power accelerators for medical and industrial applications

    Science.gov (United States)

    Van Riper, K. A.; Mashnik, S. G.; Wilson, W. B.

    2001-05-01

    Methods for radionuclide production calculation in a high power proton accelerator have been developed and applied to study production of 22 isotopes by high-energy protons and neutrons. These methods are readily applicable to accelerator, and reactor, environments other than the particular model we considered and to the production of other radioactive and stable isotopes. We have also developed methods for evaluating cross sections from a wide variety of sources into a single cross section set and have produced an evaluated library covering about a third of all natural elements. These methods also are applicable to an expanded set of reactions. A 684 page detailed report on this study, with 37 tables and 264 color figures is available on the Web at http://t2.lanl.gov/publications/publications.html, or, if not accessible, in hard copy from the authors.

  18. Portal imaging improvement with a low energy un flattened beam in high energy medical accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Krutman, Y; Faermann, S; Tsechanski, A [Ben-Gurion Univ. of the Negev, Beersheba (Israel)

    1996-12-01

    In this work we present a further improvement of the portal film option, for a Clinac 18 accelerator with a 10 MV therapeutic x-ray beam. This is done by lowering the nominal photon energy to 4 MV, therefore increasing the relative contribution of the low energy portion of the x-ray spectrum. Improvement of the image quality is demonstrated with a portal film scale tray, and with an anthropomorphic phantom, a graphical analysis demonstrates the improvement on image (authors).

  19. LANL Activities Supporting Electron Accelerator Production of 99Mo for NorthStar Medical Radioisotopes, LLC

    International Nuclear Information System (INIS)

    Dale, Gregory E.; Kelsey, Charles T. IV; Woloshun, Keith A.; Holloway, Michael A.; Olivas, Eric R.; Dalmas, Dale A.; Romero, Frank P.; Hurtle, Kenneth P.

    2012-01-01

    Summary of LANL FY12 Activities are: (1) Preparation, performance, and data analysis for the FY12 accelerator tests at ANL - (a) LANL designed and installed a closed-loop helium target cooling system at ANL for the FY12 accelerator tests, (b) Thermal test was performed on March 27, (c) 24 h production test to follow the accelerator upgrade at ANL; (2) Local target shielding design and OTR/IR recommendations - (a) Target dose rate and activation products were calculated with MCNPX, (b) 206 Pb(γ,2n) 204m Pb vs 204g Pb branching ratio unpublished, will measure using the LANL microtron, (c) OTR system nearing final configuration, (d) IR prototype system demonstrated during the recent thermal test at ANL; (3) Target housing lifetime estimation - Target housing material specifications and design to be finalized following the thermal test, lifetime not believed to be an issue; and (4) Target cooling system reliability - Long duration system characterizations will begin following the thermal test.

  20. Medical Isotope Production With The Accelerator Production of Tritium (APT) Facility

    International Nuclear Information System (INIS)

    Buckner, M.; Cappiello, M.; Pitcher, E.; O'Brien, H.

    1998-01-01

    In order to meet US tritium needs to maintain the nuclear weapons deterrent, the Department of Energy (DOE) is pursuing a dual track program to provide a new tritium source. A record of decision is planned for late in 1998 to select either the Accelerator Production of Tritium (APT) or the Commercial Light Water Reactor (CLWR) as the technology for new tritium production in the next century. To support this decision, an APT Project was undertaken to develop an accelerator design capable of producing 3 kg of tritium per year by 2007 (START I requirements). The Los Alamos National Laboratory (LANL) was selected to lead this effort with Burns and Roe Enterprises, Inc. (BREI) / General Atomics (GA) as the prime contractor for design, construction, and commissioning of the facility. If chosen in the downselect, the facility will be built at the Savannah River Site (SRS) and operated by the SRS Maintenance and Operations (M ampersand O) contractor, the Westinghouse Savannah River Company (WSRC), with long-term technology support from LANL. These three organizations (LANL, BREI/GA, and WSRC) are working together under the direction of the APT National Project Office which reports directly to the DOE Office of Accelerator Production which has program authority and responsibility for the APT Project

  1. MO-FG-303-04: A Smartphone Application for Automated Mechanical Quality Assurance of Medical Accelerators

    International Nuclear Information System (INIS)

    Kim, H; Lee, H; Choi, K; Ye, S

    2015-01-01

    Purpose: The mechanical quality assurance (QA) of medical accelerators consists of a time consuming series of procedures. Since most of the procedures are done manually – e.g., checking gantry rotation angle with the naked eye using a level attached to the gantry –, it is considered to be a process with high potential for human errors. To remove the possibilities of human errors and reduce the procedure duration, we developed a smartphone application for automated mechanical QA. Methods: The preparation for the automated process was done by attaching a smartphone to the gantry facing upward. For the assessments of gantry and collimator angle indications, motion sensors (gyroscope, accelerator, and magnetic field sensor) embedded in the smartphone were used. For the assessments of jaw position indicator, cross-hair centering, and optical distance indicator (ODI), an optical-image processing module using a picture taken by the high-resolution camera embedded in the smartphone was implemented. The application was developed with the Android software development kit (SDK) and OpenCV library. Results: The system accuracies in terms of angle detection error and length detection error were < 0.1° and < 1 mm, respectively. The mean absolute error for gantry and collimator rotation angles were 0.03° and 0.041°, respectively. The mean absolute error for the measured light field size was 0.067 cm. Conclusion: The automated system we developed can be used for the mechanical QA of medical accelerators with proven accuracy. For more convenient use of this application, the wireless communication module is under development. This system has a strong potential for the automation of the other QA procedures such as light/radiation field coincidence and couch translation/rotations

  2. MO-FG-303-04: A Smartphone Application for Automated Mechanical Quality Assurance of Medical Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H [Interdisciplinary Program in Radiation applied Life Science, College of Medicine, Seoul National University, Seoul (Korea, Republic of); Lee, H; Choi, K [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Ye, S [Interdisciplinary Program in Radiation applied Life Science, College of Medicine, Seoul National University, Seoul (Korea, Republic of); Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Department of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2015-06-15

    Purpose: The mechanical quality assurance (QA) of medical accelerators consists of a time consuming series of procedures. Since most of the procedures are done manually – e.g., checking gantry rotation angle with the naked eye using a level attached to the gantry –, it is considered to be a process with high potential for human errors. To remove the possibilities of human errors and reduce the procedure duration, we developed a smartphone application for automated mechanical QA. Methods: The preparation for the automated process was done by attaching a smartphone to the gantry facing upward. For the assessments of gantry and collimator angle indications, motion sensors (gyroscope, accelerator, and magnetic field sensor) embedded in the smartphone were used. For the assessments of jaw position indicator, cross-hair centering, and optical distance indicator (ODI), an optical-image processing module using a picture taken by the high-resolution camera embedded in the smartphone was implemented. The application was developed with the Android software development kit (SDK) and OpenCV library. Results: The system accuracies in terms of angle detection error and length detection error were < 0.1° and < 1 mm, respectively. The mean absolute error for gantry and collimator rotation angles were 0.03° and 0.041°, respectively. The mean absolute error for the measured light field size was 0.067 cm. Conclusion: The automated system we developed can be used for the mechanical QA of medical accelerators with proven accuracy. For more convenient use of this application, the wireless communication module is under development. This system has a strong potential for the automation of the other QA procedures such as light/radiation field coincidence and couch translation/rotations.

  3. Biological and medical research with accelerated heavy ions at the Bevalac, 1974--1977

    International Nuclear Information System (INIS)

    Elam, S.

    1977-04-01

    The Bevalac, a versatile high-energy heavy-ion accelerator complex, has been in operation for less than two years. A major purpose for which the Bevalac was constructed was to explore the possibility of heavy-ion teams for therapy for certain forms of cancer. Significant progress has been made in this direction. The National Cancer Institute has recognized the advantages that these and other accelerated particles offer, and heavy ions have been included in a long-term plan for particle therapy that will assess by means of controlled therapeutic tests the value of various modalities. Since accelerated heavy ions became available, the possibility of other contributions, not planned, became apparent. We are developig a new diagnostic method known as heavy-ion radiography that has greatly increased sensitivity for soft-tissue detail and that may become a powerful tool for localizing early tumors and metastases. We have discovered that radioactive beams are formed from fragmentation of stable deflected beams. Use of these autoradioactive beams is just beginning; however, we know that these beams will be helpful in localizing the region in the body where therapy is being delivered. In addition, it has been demonstrated that instant implantation of the radioactive beam allows direct measurements of blood perfusion rates in inaccessible parts of the body, and such a technique may become a new tool for the study of fast hot atom reactions in biochemistry, tracer biology and nuclear medicine. The Bevalac will also be useful for the continuation of previously developed methods for the control of acromegaly, Cushing's disease and, on a research basis, advanced diabetes mellitus with vascular disease. The ability to make small bloodless lesions in the brain and elsewhere with heavy-ion beams has great potential for nervous-system studies and perhaps later for radioneurosurgery

  4. A model for preemptive maintenance of medical linear accelerators-predictive maintenance.

    Science.gov (United States)

    Able, Charles M; Baydush, Alan H; Nguyen, Callistus; Gersh, Jacob; Ndlovu, Alois; Rebo, Igor; Booth, Jeremy; Perez, Mario; Sintay, Benjamin; Munley, Michael T

    2016-03-10

    Unscheduled accelerator downtime can negatively impact the quality of life of patients during their struggle against cancer. Currently digital data accumulated in the accelerator system is not being exploited in a systematic manner to assist in more efficient deployment of service engineering resources. The purpose of this study is to develop an effective process for detecting unexpected deviations in accelerator system operating parameters and/or performance that predicts component failure or system dysfunction and allows maintenance to be performed prior to the actuation of interlocks. The proposed predictive maintenance (PdM) model is as follows: 1) deliver a daily quality assurance (QA) treatment; 2) automatically transfer and interrogate the resulting log files; 3) once baselines are established, subject daily operating and performance values to statistical process control (SPC) analysis; 4) determine if any alarms have been triggered; and 5) alert facility and system service engineers. A robust volumetric modulated arc QA treatment is delivered to establish mean operating values and perform continuous sampling and monitoring using SPC methodology. Chart limits are calculated using a hybrid technique that includes the use of the standard SPC 3σ limits and an empirical factor based on the parameter/system specification. There are 7 accelerators currently under active surveillance. Currently 45 parameters plus each MLC leaf (120) are analyzed using Individual and Moving Range (I/MR) charts. The initial warning and alarm rule is as follows: warning (2 out of 3 consecutive values ≥ 2σ hybrid) and alarm (2 out of 3 consecutive values or 3 out of 5 consecutive values ≥ 3σ hybrid). A customized graphical user interface provides a means to review the SPC charts for each parameter and a visual color code to alert the reviewer of parameter status. Forty-five synthetic errors/changes were introduced to test the effectiveness of our initial chart limits. Forty

  5. MONITORING OF INDIVIDUAL DOSES FOR MEDICAL WORKERS OF DENTAL POLYCLINIC’S X-RAY ROOMS IN DUSHANBE, THE REPUBLIC OF TADJIKISTAN

    Directory of Open Access Journals (Sweden)

    N. U. Hakimova

    2016-01-01

    Full Text Available The article presents the data and analyses of personnel’s average annual external exposure doses monitoring via the thermoluminescent dosimetry method used for X-ray radiological personnel in dental polyclinics of Dushanbe, Tadjikistan Republic over a 5-year period ( 2010–2014 . Out of 42 registered medical institutions dental polyclinics amounted up to only just 14%. For this work thermoluminescent dosimeters were used ( with LiF: Mg, Ti with the thermoluminescent dosimetric installation “ Harshaw – 4500” as the reader device. Monitoring results comparison of individual dose equivalent Hp ( 10 values was conducted for two groups of medical workers: medical doctors and X-ray lab technicians. It is demonstrated that radiological technicians’ professional exposure doses are on the average by 23% higher than those for medical doctors.The average individual exposure doses over the above indicated period amount to 0,93 mSv and 1,3 mSv for doctors and X-ray lab technicians, respectively, and are in the range from 0,45 mSv to 2,39 mSv. The doses include contribution from the natural background. The values of doses recorded for the personnel in dental polyclinic correspond to those recorded for the workers in the routine X-ray rooms.

  6. Radiological protection in medical facilities and applications and around accelerator facilities

    International Nuclear Information System (INIS)

    Reiners, C.; Harder, D.; Messerschmidt, O.

    1992-01-01

    The proceedings of the meeting of radiation protection experts present the invited papers, of which 37 have been analysed and indexed for retrieval from the database. The papers discuss a broad spectrum of topics in the field of radiologic safety, as e.g. the fundamentals of assessing the effects of low-level ionizing radiation, new releases of international recommendations, the legal basis of activities for an optimization of radiological protection, including the tasks of the radiation protection officers, and recent developments in dose monitoring and measurement. There are papers dealing with topical aspects of radiation protection around accelerators for radiotherapy or radionuclide production, and at accelerators in research and industry. Experts in the field of diagnostic X-ray examination present the latest knowledge contributing to minimizing the radiation exposure from conventional or from novel, digital examination techniques, and recent developments in the field of quality assurance. In connection with the handling of unsealed radioactive materials, there are some papers discussing the monitoring and limits of intakes of radionuclides by workers. (orig./HP) With 124 figs., 72 tabs [de

  7. CLIC: Overview of applications using high-gradient acceleration, from photon sources to medical physics

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    The Compact Linear Collider (CLIC) is a future electron-positron collider under study. It foresees e+e- collisions at centre-of-mass energies ranging from a few hundred GeV up to 3 TeV. The CLIC study is an international collaboration hosted by CERN. The lectures provide a broad overview of the CLIC project, covering the physics potential, the particle detectors and the accelerator. An overview of the CLIC physics opportunities is presented. These are best exploited in a staged construction and operation scenario of the collider. The detector technologies, fulfilling CLIC performance requirements and currently under study, are described. The accelerator design and performance, together with its major technologies, are presented in the light of ongoing component tests and large system tests. The status of the optimisation studies (e.g. for cost and power) of the CLIC complex for the proposed energy staging is included. One lecture is dedicated to the use of CLIC technologies in free electron lasers and other ...

  8. Investigating Perceived vs. Medical Weight Status Classification among College Students: Room for Improvement Exists among the Overweight and Obese

    Science.gov (United States)

    Duffrin, Christopher; Eakin, Angela; Bertrand, Brenda; Barber-Heidel, Kimberly; Carraway-Stage, Virginia

    2011-01-01

    The American College Health Association estimated that 31% of college students are overweight or obese. It is important that students have a correct perception of body weight status as extra weight has potential adverse health effects. This study assessed accuracy of perceived weight status versus medical classification among 102 college students.…

  9. Particle accelerators installed in hospitals: the need for a program of training for medical physicists

    International Nuclear Information System (INIS)

    Brandan, M.E.

    1989-01-01

    This paper was presented at the session which closed the round table. The need for setting up a program of professional training directed by hospital physicists who have functioned for some time as medical physicists in the health centers of the country was proposed. (Author)

  10. Experimental investigations of the neutron contamination in high-energy photon fields at medical linear accelerators

    International Nuclear Information System (INIS)

    Brunckhorst, Elin

    2009-01-01

    The scope of this thesis was to develop a device for the detection of the photoneutron dose inside the high-energy photon field. The photoneutron contamination of a Siemens PRIMUS linear accelerator was investigated in detail in its 15 MV photon mode. The experimental examinations were performed with three ionisation chambers (a tissue equivalent chamber, a magnesium chamber and a 10 B-coated magnesium chamber) and two types of thermoluminescence detectors (enriched with 6 Li and 7 Li, respectively). The detectors have different sensitivities to photons and neutrons and their combination allows the dose separation in a mixed neutron/photon field. The application of the ionisation chamber system, as well as the present TLD system for photoneutron detection in high-energy photon beams is a new approach. The TLD neutron sensitivity was found to be too low for a measurement inside the open photon field and the further investigation focused on the ionisation chambers. The three ionisation chambers were calibrated at different photon and neutron sources and a the borated magnesium chamber showed a very high response to thermal neutrons. For a cross check of the calibration, the three chambers were also used for dose separation of a boron neutron capture therapy beam where the exact determination of the thermal neutron dose is essential. Very accurate results were achieved for the thermal neutron dose component. At the linear accelerator the chamber system was reduced to a paired chamber system utilising the two magnesium chambers, since the fast neutron component was to small to be separated. The neutron calibration of the three chambers could not be applied, instead a conversion of measured thermal neutron signal by the borated chamber to Monte Carlo simulated total neutron dose was performed. Measurements for open fields in solid water and liquid water were performed with the paired chamber system. In larger depths the neutron dose could be determined with an

  11. Experimental investigations of the neutron contamination in high-energy photon fields at medical linear accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Brunckhorst, Elin

    2009-02-26

    The scope of this thesis was to develop a device for the detection of the photoneutron dose inside the high-energy photon field. The photoneutron contamination of a Siemens PRIMUS linear accelerator was investigated in detail in its 15 MV photon mode. The experimental examinations were performed with three ionisation chambers (a tissue equivalent chamber, a magnesium chamber and a {sup 10}B-coated magnesium chamber) and two types of thermoluminescence detectors (enriched with {sup 6}Li and {sup 7}Li, respectively). The detectors have different sensitivities to photons and neutrons and their combination allows the dose separation in a mixed neutron/photon field. The application of the ionisation chamber system, as well as the present TLD system for photoneutron detection in high-energy photon beams is a new approach. The TLD neutron sensitivity was found to be too low for a measurement inside the open photon field and the further investigation focused on the ionisation chambers. The three ionisation chambers were calibrated at different photon and neutron sources and a the borated magnesium chamber showed a very high response to thermal neutrons. For a cross check of the calibration, the three chambers were also used for dose separation of a boron neutron capture therapy beam where the exact determination of the thermal neutron dose is essential. Very accurate results were achieved for the thermal neutron dose component. At the linear accelerator the chamber system was reduced to a paired chamber system utilising the two magnesium chambers, since the fast neutron component was to small to be separated. The neutron calibration of the three chambers could not be applied, instead a conversion of measured thermal neutron signal by the borated chamber to Monte Carlo simulated total neutron dose was performed. Measurements for open fields in solid water and liquid water were performed with the paired chamber system. In larger depths the neutron dose could be determined

  12. Room Acoustics

    Science.gov (United States)

    Kuttruff, Heinrich; Mommertz, Eckard

    The traditional task of room acoustics is to create or formulate conditions which ensure the best possible propagation of sound in a room from a sound source to a listener. Thus, objects of room acoustics are in particular assembly halls of all kinds, such as auditoria and lecture halls, conference rooms, theaters, concert halls or churches. Already at this point, it has to be pointed out that these conditions essentially depend on the question if speech or music should be transmitted; in the first case, the criterion for transmission quality is good speech intelligibility, in the other case, however, the success of room-acoustical efforts depends on other factors that cannot be quantified that easily, not least it also depends on the hearing habits of the listeners. In any case, absolutely "good acoustics" of a room do not exist.

  13. TU-F-CAMPUS-T-01: Dose and Energy Spectra From Neutron Induced Radioactivity in Medical Linear Accelerators Following High Energy Total Body Irradiation

    International Nuclear Information System (INIS)

    Keehan, S; Taylor, M; Franich, R; Smith, R; Dunn, L; Kron, T

    2015-01-01

    Purpose: To assess the risk posed by neutron induced activation of components in medical linear accelerators (linacs) following the delivery of high monitor unit 18 MV photon beams such as used in TBI. Methods: Gamma spectroscopy was used to identify radioisotopes produced in components of a Varian 21EX and an Elekta Synergy following delivery of photon beams. Dose and risk estimates for TBI were assessed using dose deliveries from an actual patient treatment. A 1 litre spherical ion chamber (PTW, Germany) has been used to measure the dose at the beam exit window and at the total body irradiation (TBI) treatment couch following large and small field beams with long beam-on times. Measurements were also made outside of the closed jaws to quantify the benefit of the attenuation provided by the jaws. Results: The radioisotopes produced in the linac head have been identified as 187 W, 56 Mn, 24 Na and 28 Al, which have half-lives from between 2.3 min to 24 hours. The dose at the beam exit window following an 18 MV 2197 MU TBI beam delivery was 12.6 µSv in ten minutes. The dose rate at the TBI treatment couch 4.8 m away is a factor of ten lower. For a typical TBI delivered in six fractions each consisting of four beams and an annual patient load of 24, the annual dose estimate for a staff member at the treatment couch for ten minutes is 750 µSv. This can be further reduced by a factor of about twelve if the jaws are closed before entering the room, resulting in a dose estimate of 65 µSv. Conclusion: The dose resulting from the activation products for a representative TBI workload at our clinic of 24 patients per year is 750 µSv, which can be further reduced to 65 µSv by closing the jaws

  14. Successful strategies for the reduction of operating room turnover times in a tertiary care academic medical center.

    Science.gov (United States)

    Kodali, Bhavani S; Kim, Dennie; Bleday, Ronald; Flanagan, Hugh; Urman, Richard D

    2014-04-01

    Turnover time (TOT) is one of the classic measures of operating room (OR) efficiency. There have been numerous efforts to reduce TOTs, sometimes through the employment of a process improvement framework. However, most examples of process improvement in the TOT focus primarily on operational changes to workflows and statistical significance. These examples of process improvement do not detail the complex organizational challenges associated with implementing, expanding, and sustaining change. TOT data for general and gastrointestinal surgery were collected retrospectively over a 26-mo period at a large multispecialty academic institution. We calculated mean and median TOTs. TOTs were excluded if the sequence of cases was changed or cases were canceled. Data were retrieved from the perioperative nursing data entry system. Using performance improvement strategies, we determined how various events and organizational factors created an environment that was receptive to change. This ultimately led to a sustained decrease in the OR TOT both in the general and gastrointestinal surgery ORs that were the focus of the study (44.8 min versus 48.6 min; P managers, and change agents commonly face. Awareness of the numerous variables that may support or impede a particular change effort can inform effective change implementation strategies that are "organizationally compatible." Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Monte Carlo simulation of a medical linear accelerator for generation of phase spaces

    International Nuclear Information System (INIS)

    Oliveira, Alex C.H.; Santana, Marcelo G.; Lima, Fernando R.A.; Vieira, Jose W.

    2013-01-01

    Radiotherapy uses various techniques and equipment for local treatment of cancer. The equipment most often used in radiotherapy to the patient irradiation are linear accelerators (Linacs) which produce beams of X-rays in the range 5-30 MeV. Among the many algorithms developed over recent years for evaluation of dose distributions in radiotherapy planning, the algorithms based on Monte Carlo methods have proven to be very promising in terms of accuracy by providing more realistic results. The MC methods allow simulating the transport of ionizing radiation in complex configurations, such as detectors, Linacs, phantoms, etc. The MC simulations for applications in radiotherapy are divided into two parts. In the first, the simulation of the production of the radiation beam by the Linac is performed and then the phase space is generated. The phase space contains information such as energy, position, direction, etc. og millions of particles (photos, electrons, positrons). In the second part the simulation of the transport of particles (sampled phase space) in certain configurations of irradiation field is performed to assess the dose distribution in the patient (or phantom). The objective of this work is to create a computational model of a 6 MeV Linac using the MC code Geant4 for generation of phase spaces. From the phase space, information was obtained to asses beam quality (photon and electron spectra and two-dimensional distribution of energy) and analyze the physical processes involved in producing the beam. (author)

  16. SU-CD-PinS Room/Hall E-00: HAZMAT Training for the Medical Physicist - Part I

    International Nuclear Information System (INIS)

    2016-01-01

    Medical Physicists are frequently involved in shipping radioactive materials or supervising those who do. Current U.S. Department of Transportation Hazardous Material Regulations, 49 CFR Parts 171 - 185, require hazmat employees to have documented training specified in 49 CFR 172 Subpart H. A hazmat employee is defined as an individual who: (1) loads, unloads or handles hazardous material; (2) manufactures, tests, reconditions, repairs, modifies, marks or otherwise represents containers, drums or packagings as qualified for use in the transportation of hazardous materials; (3) prepares hazardous materials for transportation; (4) is responsible for safety of transporting hazardous materials; or (5) operates a vehicle used to transport hazardous materials. Recurrent training is required at least once every three years. (The IATA two-year training interval is not applicable and is generally misunderstood.) FAA has escalated inspection and enforcement. Facilities who ship radiopharmaceuticals to other laboratories, return radiopharmaceuticals or radioactive sources to suppliers, or otherwise ship radioactive materials have been cited for failure to provide and document the required training. The interrelationship of transportation regulations, 49 CFR, IATA, ICAO and other transportation regulations, which are frequently misunderstood, will be explained. The course will cover typical shipments by air and highway which are encountered in a medical institution. Items such as fissile materials, highway route controlled quantities, rail shipments, vessel shipments and such will be omitted; although specific questions may be addressed. A major objective of the course is to present the process of shipping radioactive material in a sequential and logical fashion. How radioactive materials for transportation purposes are defined by activity concentrations for exempt materials and activity limits for exempt consignments will be explained. Radioactive material shipments of

  17. SU-G-PinS Room/Hall E-00: HAZMAT Training for the Medical Physicist - Part II

    International Nuclear Information System (INIS)

    2016-01-01

    Medical Physicists are frequently involved in shipping radioactive materials or supervising those who do. Current U.S. Department of Transportation Hazardous Material Regulations, 49 CFR Parts 171 - 185, require hazmat employees to have documented training specified in 49 CFR 172 Subpart H. A hazmat employee is defined as an individual who: (1) loads, unloads or handles hazardous material; (2) manufactures, tests, reconditions, repairs, modifies, marks or otherwise represents containers, drums or packagings as qualified for use in the transportation of hazardous materials; (3) prepares hazardous materials for transportation; (4) is responsible for safety of transporting hazardous materials; or (5) operates a vehicle used to transport hazardous materials. Recurrent training is required at least once every three years. (The IATA two year training interval is not applicable and is generally misunderstood.) FAA has escalated inspection and enforcement. Facilities who ship radiopharmaceuticals to other laboratories, return radiopharmaceuticals or radioactive sources to suppliers, or otherwise ship radioactive materials have been cited for failure to provide and document the required training. The interrelationship of transportation regulations, 49 CFR, IATA, ICAO and other transportation regulations, which are frequently misunderstood, will be explained. The course will cover typical shipments by air and highway which are encountered in a medical institution. Items such as fissile materials, highway route controlled quantities, rail shipments, vessel shipments and such will be omitted; although specific questions may be addressed. A major objective of the course is to present the process of shipping radioactive material in a sequential and logical fashion. How radioactive materials for transportation purposes are defined by activity concentrations for exempt materials and activity limits for exempt consignments will be explained. Radioactive material shipments of

  18. SU-CD-PinS Room/Hall E-00: HAZMAT Training for the Medical Physicist - Part I

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Medical Physicists are frequently involved in shipping radioactive materials or supervising those who do. Current U.S. Department of Transportation Hazardous Material Regulations, 49 CFR Parts 171 - 185, require hazmat employees to have documented training specified in 49 CFR 172 Subpart H. A hazmat employee is defined as an individual who: (1) loads, unloads or handles hazardous material; (2) manufactures, tests, reconditions, repairs, modifies, marks or otherwise represents containers, drums or packagings as qualified for use in the transportation of hazardous materials; (3) prepares hazardous materials for transportation; (4) is responsible for safety of transporting hazardous materials; or (5) operates a vehicle used to transport hazardous materials. Recurrent training is required at least once every three years. (The IATA two-year training interval is not applicable and is generally misunderstood.) FAA has escalated inspection and enforcement. Facilities who ship radiopharmaceuticals to other laboratories, return radiopharmaceuticals or radioactive sources to suppliers, or otherwise ship radioactive materials have been cited for failure to provide and document the required training. The interrelationship of transportation regulations, 49 CFR, IATA, ICAO and other transportation regulations, which are frequently misunderstood, will be explained. The course will cover typical shipments by air and highway which are encountered in a medical institution. Items such as fissile materials, highway route controlled quantities, rail shipments, vessel shipments and such will be omitted; although specific questions may be addressed. A major objective of the course is to present the process of shipping radioactive material in a sequential and logical fashion. How radioactive materials for transportation purposes are defined by activity concentrations for exempt materials and activity limits for exempt consignments will be explained. Radioactive material shipments of

  19. SU-G-PinS Room/Hall E-00: HAZMAT Training for the Medical Physicist - Part II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Medical Physicists are frequently involved in shipping radioactive materials or supervising those who do. Current U.S. Department of Transportation Hazardous Material Regulations, 49 CFR Parts 171 - 185, require hazmat employees to have documented training specified in 49 CFR 172 Subpart H. A hazmat employee is defined as an individual who: (1) loads, unloads or handles hazardous material; (2) manufactures, tests, reconditions, repairs, modifies, marks or otherwise represents containers, drums or packagings as qualified for use in the transportation of hazardous materials; (3) prepares hazardous materials for transportation; (4) is responsible for safety of transporting hazardous materials; or (5) operates a vehicle used to transport hazardous materials. Recurrent training is required at least once every three years. (The IATA two year training interval is not applicable and is generally misunderstood.) FAA has escalated inspection and enforcement. Facilities who ship radiopharmaceuticals to other laboratories, return radiopharmaceuticals or radioactive sources to suppliers, or otherwise ship radioactive materials have been cited for failure to provide and document the required training. The interrelationship of transportation regulations, 49 CFR, IATA, ICAO and other transportation regulations, which are frequently misunderstood, will be explained. The course will cover typical shipments by air and highway which are encountered in a medical institution. Items such as fissile materials, highway route controlled quantities, rail shipments, vessel shipments and such will be omitted; although specific questions may be addressed. A major objective of the course is to present the process of shipping radioactive material in a sequential and logical fashion. How radioactive materials for transportation purposes are defined by activity concentrations for exempt materials and activity limits for exempt consignments will be explained. Radioactive material shipments of

  20. Coating of human decay accelerating factor (hDAF) onto medical devices to improve biocompatibility.

    Science.gov (United States)

    Watkins, N J; Braidley, P; Bray, C J; Savill, C M; White, D J

    1997-12-01

    In passing blood through an artificial circulatory system, the blood is exposed to surfaces that result in activation of the complement system. The consequences of the activation of complement can be extremely serious for the patient ranging from mild discomfort to respiratory distress and even anaphylaxis. An entirely novel approach was to express recombinant GPI anchored human decay accelerating factor (hDAF) using the baculovirus system and then coat the recombinant protein onto the surfaces of these materials to reduce complement activation. Expression of hDAF in Sf9 cells was shown by ELISA, FACS analysis, and Western blot. Functional activity was tested by CH50 assay. For the coating experiments a small scale model of a cardiovascular bypass circuit constructed from COBE tubing was used. hDAF was either coated onto the circuit using adsorption or covalently linked via the photoreactive crosslinker, p-azidobenzoyl hydrazide. After coating, heparinised human blood was pumped around the circuit and samples were collected into EDTA collection tubes at different time points. Complement activation was measured using a Quidel C3a-des-arg EIA. The photolinked circuits gave a reduction in C3a production of 20-50%, compared to 10-20% seen with an absorbed hDAF circuit. Furthermore, the inhibition of complement was seen over the whole time scale of the photolinked circuit, 60-90 min, whilst in the adsorbed circuit inhibition was not seen to a significant degree after 60 min. The time scale of a standard cardiac bypass is 45-90 min, therefore, the photolinked circuit results are encouraging, as significant inhibition of complement activation is seen within this time frame.

  1. A collimated detection system for assessing leakage dose from medical linear accelerators at the patient plane.

    Science.gov (United States)

    Lonski, P; Taylor, M L; Franich, R D; Kron, T

    2014-03-01

    Leakage radiation from linear accelerators can make a significant contribution to healthy tissue dose in patients undergoing radiotherapy. In this work thermoluminescent dosimeters (LiF:Mg,Cu,P TLD chips) were used in a focused lead cone loaded with TLD chips for the purpose of evaluating leakage dose at the patient plane. By placing the TLDs at one end of a stereotactic cone, a focused measurement device is created; this was tested both in and out of the primary beam of a Varian 21-iX linac using 6 MV photons. Acrylic build up material of 1.2 cm thickness was used inside the cone and measurements made with either one or three TLD chips at a given distance from the target. Comparing the readings of three dosimeters in one plane inside the cone offered information regarding the orientation of the cone relative to a radiation source. Measurements in the patient plane with the linac gantry at various angles demonstrated that leakage dose was approximately 0.01% of the primary beam out of field when the cone was pointed directly towards the target and 0.0025% elsewhere (due to scatter within the gantry). No specific 'hot spots' (e.g., insufficient shielding or gaps at abutments) were observed. Focused cone measurements facilitate leakage dose measurements from the linac head directly at the patient plane and allow one to infer the fraction of leakage due to 'direct' photons (along the ray-path from the bremsstrahlung target) and that due to scattered photons.

  2. A collimated detection system for assessing leakage dose from medical linear accelerators at the patient plane

    International Nuclear Information System (INIS)

    Lonski, P.; Kron, T.; Taylor, M.L.; Franich, R.D.

    2014-01-01

    Leakage radiation from linear accelerators can make a significant contribution to healthy tissue dose in patients undergoing radiotherapy. In this work thermoluminescent dosimeters (LiF:Mg,Cu,P TLD chips) were used in a focused lead cone loaded with TLD chips for the purpose of evaluating leakage dose at the patient plane. By placing the TLDs at one end of a stereotactic cone, a focused measurement device is created; this was tested both in and out of the primary beam of a Varian 21-iX linac using 6 MV photons. Acrylic build up material of 1.2 cm thickness was used inside the cone and measurements made with either one or three TLD chips at a given distance from the target. Comparing the readings of three dosimeters in one plane inside the cone offered information regarding the orientation of the cone relative to a radiation source. Measurements in the patient plane with the linac gantry at various angles demonstrated that leakage dose was approximately 0.01 % of the primary beam out of field when the cone was pointed directly towards the target and 0.0025 % elsewhere (due to scatter within the gantry). No specific ‘hot spots’ (e.g., insufficient shielding or gaps at abutments) were observed. Focused cone measurements facilitate leakage dose measurements from the linac head directly at the patient plane and allow one to infer the fraction of leakage due to ‘direct’ photons (along the ray-path from the bremsstrahlung target) and that due to scattered photons.

  3. Commissioning of a medical accelerator photon beam Monte Carlo simulation using wide-field profiles

    International Nuclear Information System (INIS)

    Pena, J; Franco, L; Gomez, F; Iglesias, A; Lobato, R; Mosquera, J; Pazos, A; Pardo, J; Pombar, M; RodrIguez, A; Sendon, J

    2004-01-01

    A method for commissioning an EGSnrc Monte Carlo simulation of medical linac photon beams through wide-field lateral profiles at moderate depth in a water phantom is presented. Although depth-dose profiles are commonly used for nominal energy determination, our study shows that they are quite insensitive to energy changes below 0.3 MeV (0.6 MeV) for a 6 MV (15 MV) photon beam. Also, the depth-dose profile dependence on beam radius adds an additional uncertainty in their use for tuning nominal energy. Simulated 40 cm x 40 cm lateral profiles at 5 cm depth in a water phantom show greater sensitivity to both nominal energy and radius. Beam parameters could be determined by comparing only these curves with measured data

  4. Commissioning of a medical accelerator photon beam Monte Carlo simulation using wide-field profiles

    Energy Technology Data Exchange (ETDEWEB)

    Pena, J [Departamento de Fisica de PartIculas, Facultade de Fisica, 15782 Santiago de Compostela (Spain); Franco, L [Departamento de Fisica de PartIculas, Facultade de Fisica, 15782 Santiago de Compostela (Spain); Gomez, F [Departamento de Fisica de PartIculas, Facultade de Fisica, 15782 Santiago de Compostela (Spain); Iglesias, A [Departamento de Fisica de PartIculas, Facultade de Fisica, 15782 Santiago de Compostela (Spain); Lobato, R [Hospital ClInico Universitario de Santiago, Santiago de Compostela (Spain); Mosquera, J [Hospital ClInico Universitario de Santiago, Santiago de Compostela (Spain); Pazos, A [Departamento de Fisica de PartIculas, Facultade de Fisica, 15782 Santiago de Compostela (Spain); Pardo, J [Departamento de Fisica de PartIculas, Facultade de Fisica, 15782 Santiago de Compostela (Spain); Pombar, M [Hospital ClInico Universitario de Santiago, Santiago de Compostela (Spain); RodrIguez, A [Departamento de Fisica de PartIculas, Facultade de Fisica, 15782 Santiago de Compostela (Spain); Sendon, J [Hospital ClInico Universitario de Santiago, Santiago de Compostela (Spain)

    2004-11-07

    A method for commissioning an EGSnrc Monte Carlo simulation of medical linac photon beams through wide-field lateral profiles at moderate depth in a water phantom is presented. Although depth-dose profiles are commonly used for nominal energy determination, our study shows that they are quite insensitive to energy changes below 0.3 MeV (0.6 MeV) for a 6 MV (15 MV) photon beam. Also, the depth-dose profile dependence on beam radius adds an additional uncertainty in their use for tuning nominal energy. Simulated 40 cm x 40 cm lateral profiles at 5 cm depth in a water phantom show greater sensitivity to both nominal energy and radius. Beam parameters could be determined by comparing only these curves with measured data.

  5. Voluntary medical male circumcision: an introduction to the cost, impact, and challenges of accelerated scaling up.

    Directory of Open Access Journals (Sweden)

    Catherine Hankins

    2011-11-01

    Full Text Available Scaling up voluntary medical male circumcision (VMMC for HIV prevention is cost saving and creates fiscal space in the future that otherwise would have been encumbered by antiretroviral treatment costs. An investment of US$1,500,000,000 between 2011 and 2015 to achieve 80% coverage in 13 priority countries in southern and eastern Africa will result in net savings of US$16,500,000,000. Strong political leadership, country ownership, and stakeholder engagement, along with effective demand creation, community mobilisation, and human resource deployment, are essential. This collection of articles on determining the cost and impact of VMMC for HIV prevention signposts the way forward to scaling up VMMC service delivery safely and efficiently to reap individual- and population-level benefits.

  6. Calculation of the structural shielding of the radiotherapy treatment room equipped with a linear accelerator type Tomo therapy Hi-Art in the Oncology Center of Chihuahua, Mexico

    International Nuclear Information System (INIS)

    Caballero G, C. A.; Plascencia, J. C.; Vargas V, M. X.; Toledo J, P.

    2010-09-01

    The helicoid tomo therapy is an external radiotherapy system of modulated intensity, guided by image, in which the radiation is imparted to the patient using a narrow radiation beam in helicoid form, in a similar way to the scanning process with a computerized tomography. The tomo therapy equipment (Tomo Therapy Hi-Art) consists in an electrons linear accelerator with acceleration voltages of 6 MV for treatment and 3.5 MV for image, coupled to a ring that turn around the patient as this is transferred through this ring in perpendicular sense to the radiation beam. The radiation beam is narrow because has the maximum size of 5 x 40 cm 2 in the isocenter. The intensity modulation of the beam is carried out with a binary dynamic collimator of 64 crisscross sheets, and the guide by image though a system of megavoltage computerized tomography. Opposed to the radiation beam, also coupled to the rotational ring, a group of lead plates exists with a total thickness of 13 cm that acts as barrier of the primary radiation beam. The special configuration of the tomography equipment makes to have the following characteristics: 1) the presence of the lead barrier of the equipment reduces the intensity of the primary beam that reaches the bunker walls in considerable way, 2) the disperse and leakage radiations are increased with regard to a conventional accelerator due to the increase in the necessary irradiation time to produce modulated intensity fields by means of the narrow radiation beam. These special characteristics of the tomo therapy equipment make that particularities exist in the application of the formulations for structural shielding calculations that appears in the NCRP reports 49, NCRP 151 and IAEA-SRS-47. For this reason, several researches have development analytic models based on geometric considerations of continuous rotation of the equipment ring to determine the shielding requirements for the primary beam, the dispersed and leakage radiation in tomo therapy

  7. Probabilistic safety assessment (PSA) of the radiotherapy treatment process with an Electron Linear Accelerator (LINAC) for medical uses

    International Nuclear Information System (INIS)

    Vilaragut Llanes, J.J.; Ferro Fernandez, R.; Rodriguez Marti, M.; Ramirez, M.L.; Perez Mulas, A.; Barrientos Montero, M.; Ortiz Lopez, P.; Somoano, F.; Delgado Rodriguez, J.M.; Papadopulos, S.B.; Pereira, P.P. Jr.; Lopez Morones, R.; Larrinaga Cortinai, E.; Rivero Oliva, J.J.; Alemany, J.

    2008-01-01

    This paper presents the results of the Probabilistic Safety Assessment (PSA) to the radiotherapy treatment process with an Electron Linear Accelerator (LINAC) for Medical Uses, which was conducted in the framework of the Extra budgetary Programme on Nuclear and Radiological Safety in Iberian-America. The PSA tools were used to evaluate occupational, public and medical exposures during treatment. The study focused on the radiological protection of patients. Equipment Failure Modes and Human Errors were evaluated for each system and treatment phase by FMEA. It was aimed at obtaining an exhaustive list of deviations with a reasonable probability of occurrence and which might produce significant adverse outcomes. Separate events trees were constructed for each initiating event group. Each event tree had a different structure since the initiating events were grouped according to mitigation requirements. Fault tree models were constructed for each top event. The fault trees were developed up to the level of components. In addition to hardware faults, the fault trees included human errors associated with the response to accidents, and human errors associated with the treatment. Each accident sequence was quantified. The combination of the initiating event and top events through one fault tree was the method used to analyse the accident sequences. After combining the appropriate models, a Boolean reduction was conducted by computer software to produce sequence cut sets. Several findings were analysed concerning the treatment process and the study proposed safety recommendations to avoid them. (author)

  8. New Production Routes for Medical Isotopes 64Cu and 67Cu Using Accelerator Neutrons

    Science.gov (United States)

    Kin, Tadahiro; Nagai, Yasuki; Iwamoto, Nobuyuki; Minato, Futoshi; Iwamoto, Osamu; Hatsukawa, Yuichi; Segawa, Mariko; Harada, Hideo; Konno, Chikara; Ochiai, Kentaro; Takakura, Kosuke

    2013-03-01

    We have measured the activation cross sections producing 64Cu and 67Cu, promising medical radioisotopes for molecular imaging and radioimmunotherapy, by bombarding a natural zinc sample with 14 MeV neutrons. We estimated the production yields of 64Cu and 67Cu by fast neutrons from \\text{natC(d,n) with 40 MeV 5 mA deuterons. We used the present result together with the evaluated cross section of Zn isotopes. The calculated 64Cu yield is 1.8 TBq (175 g 64Zn) for 12 h of irradiation; the yields of 67Cu by 67Zn(n,p)67Cu and 68Zn(n,x)67Cu were 249 GBq (184 g 67Zn) and 287 GBq (186 g 68Zn) at the end of 2 days of irradiation, respectively. From the results, we proposed a new route to produce 67Cu with very little radionuclide impurity via the 68Zn(n,x)67Cu reaction, and showed the 64Zn(n,p)64Cu reaction to be a promising route to produce 64Cu. Both 67Cu and 64Cu are noted to be produced using fast neutrons.

  9. Determination of the exposure speed of radiation emitted by the linear accelerator, using the code MCNP5 to evaluate the radiotherapy room shields of ABC Hospital; Determinacion de la rapidez de exposicion de la radiacion emitida por el acelerador lineal, utilizando el codigo MCNP5, para evaluar los blindajes de la sala de radioterapia del Hospital ABC

    Energy Technology Data Exchange (ETDEWEB)

    Corral B, J. R.

    2015-07-01

    Humans should avoid exposure to radiation, because the consequences are harmful to health. Although there are different emission sources of radiation, generated by medical devices they are usually of great interest, since people who attend hospitals are exposed in one way or another to ionizing radiation. Therefore, is important to conduct studies on radioactive levels that are generated in hospitals, as a result of the use of medical equipment. To determine levels of exposure speed of a radioactive facility there are different methods, including the radiation detector and computational method. This thesis uses the computational method. With the program MCNP5 was determined the speed of the radiation exposure in the radiotherapy room of Cancer Center of ABC Hospital in Mexico City. In the application of computational method, first the thicknesses of the shields were calculated, using variables as: 1) distance from the shield to the source; 2) desired weekly equivalent dose; 3) weekly total dose equivalent emitted by the equipment; 4) occupation and use factors. Once obtained thicknesses, we proceeded to model the bunker using the mentioned program. The program uses the Monte Carlo code to probabilistic ally determine the phenomena of interaction of radiation with the shield, which will be held during the X-ray emission from the linear accelerator. The results of computational analysis were compared with those obtained experimentally with the detection method, for which was required the use of a Geiger-Muller counter and the linear accelerator was programmed with an energy of 19 MV with 500 units monitor positioning the detector in the corresponding boundary. (Author)

  10. Adjoint acceleration of Monte Carlo simulations using TORT/MCNP coupling approach: A case study on the shielding improvement for the cyclotron room of the Buddhist Tzu Chi General Hospital

    International Nuclear Information System (INIS)

    Sheu, R. J.; Sheu, R. D.; Jiang, S. H.; Kao, C. H.

    2005-01-01

    Full-scale Monte Carlo simulations of the cyclotron room of the Buddhist Tzu Chi General Hospital were carried out to improve the original inadequate maze design. Variance reduction techniques are indispensable in this study to facilitate the simulations for testing a variety of configurations of shielding modification. The TORT/MCNP manual coupling approach based on the Consistent Adjoint Driven Importance Sampling (CADIS) methodology has been used throughout this study. The CADIS utilises the source and transport biasing in a consistent manner. With this method, the computational efficiency was increased significantly by more than two orders of magnitude and the statistical convergence was also improved compared to the unbiased Monte Carlo run. This paper describes the shielding problem encountered, the procedure for coupling the TORT and MCNP codes to accelerate the calculations and the calculation results for the original and improved shielding designs. In order to verify the calculation results and seek additional accelerations, sensitivity studies on the space-dependent and energy-dependent parameters were also conducted. (authors)

  11. Recovery Room

    African Journals Online (AJOL)

    defined postoperative unit or on the hospital ward. Patients were frequently transferred from the operating room directly to the ward where they were placed close to the nursing station. In 1947 the. Anesthesia Study Commission of the Philadelphia.

  12. Planetary method to measure the neutrons spectrum in lineal accelerators of medical use; Metodo planetario para medir el espectro de neutrones en aceleradores lineales de uso medico

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Benites R, J. L., E-mail: fermineutron@yahoo.com [Centro Estatal de Cancerologia de Nayarit, Servicio de Seguridad Radiologica, Calzada de la Cruz 118 Sur, 63000 Tepic, Nayarit (Mexico)

    2014-08-15

    A novel procedure to measure the neutrons spectrum originated in a lineal accelerator of medical use has been developed. The method uses a passive spectrometer of Bonner spheres. The main advantage of the method is that only requires of a single shot of the accelerator. When this is used around a lineal accelerator is necessary to operate it under the same conditions so many times like the spheres that contain the spectrometer, activity that consumes enough time. The developed procedure consists on situating all the spheres of the spectrometer at the same time and to realize the reading making a single shot. With this method the photo neutrons spectrum produced by a lineal accelerator Varian ix of 15 MV to 100 cm of the isocenter was determined, with the spectrum is determined the total flow and the ambient dose equivalent. (Author)

  13. Highly Compact Accelerator-Driven Subcritical Assembly for Medical and Industrial Applications

    International Nuclear Information System (INIS)

    Jasmina Vujic; William Kastenberg; Ehud Greenspan; Ka-Ngo Leung

    2006-01-01

    A novel, highly compact, fusion neutron source (CNS) based on a coaxial electrostatic accelerator is under development at the Lawrence Berkeley National Laboratory. This source is designed to generate up to ∼1012 D-D n/s. This source intensity is an order of magnitude too small for Boron Neutron Capture Therapy (BNCT) applications. The objective of this project is to assess the feasibility of using a small, safe and inexpensive subcritical fission assembly to multiply the fusion neutrons by a factor of (ge)30. The overall design objective is to get a treatment time for deep seated rain tumors that does not significantly increase beyond one hour when the effective multiplication factor of the SCM is k eff = 0.98. There are two major parts to this study: the optimization of the Sub-Critical Multiplier (SCM) and the optimization of the Beam Shaping Assembly (BSA), including the reflector for both subsystems. The SCM optimization objective is to maximize the current of neutrons that leak out from the SCM in the direction of the patient, without exceeding the maximum permissible k eff . Minimizing the required uranium inventory is another objective. SCM design variables considered include the uranium enrichment level in the range not exceeding 20% 235U (for proliferation concerns), SCM geometry and dimensions, fuel thickness and moderator thickness. The objective of the BSA optimization is to maximize the tumor dose rate using the optimal SCM while maintaining a tumor-to-normal tissue dose ratio of at least 20 to 12.5 (corresponding to the tumor control dose and to the healthy tissue dose limit). The BSA design variables include its shape, dimensions and composition. The reflector optimization is, in fact, an integral part of the SCM optimization and of the BSA optimization. The reflector design variables are composition and thickness. The study concludes that it is not quite feasible to achieve the project objective. Nevertheless, it appears feasible to develop a

  14. Development of a Magnetron Resonance Frequency Auto Tuning System for Medical Xband [9300 MHz] RF Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Sung Su; Lee, Byung Cheol [University of Science and Technology, Daejeon (Korea, Republic of); Kim, Yujong; Park, Hyung Dal; Lee, Byeong-No; Joo, Youngwoo; Cha, Hyungki; Lee, Soo Min; Song, Ki Baek [KAERI, Daejeon (Korea, Republic of); Lee, Seung Hyun [Sungkyunkwan University, Suwon (Korea, Republic of)

    2015-05-15

    The total components of the accelerator are the magnetron, electron gun, accelerating structure, a set of solenoid magnets, four sets of steering coils, a modulator, and a circulator. One of the accelerator components of the accelerating structure is made of oxygen-free high-conductivity copper (OFHC), and its volume is changed according to the ambient temperature. As the volume changes, the resonant frequency of the accelerating structure is changed. Accordingly, the resonance frequency is mismatched between the source of the magnetron and the accelerating structure. An automatic frequency tuning system is automatically matched with the resonant frequency of the magnetron and accelerating structure, which allows a high output power and reliable accelerator operation. An automatic frequency tuning system is composed of a step motor control part for correcting the frequency of the source and power measuring parts, i.e., the forward and reflected power between the magnetron and accelerating structure. In this paper, the design, fabrication, and RF power test of the automatic frequency tuning system for the X-band linac are presented. A frequency tuning system was developed to overcome an unstable accelerator operation owing to the frequency mismatch between the magnetron and accelerating structure. The frequency measurement accuracy is 100 kHz and 0.72 degree per pulse.

  15. Comparison of quality assurance for performance and safety characteristics of the facility for Boron Neutron Capture therapy in Petten/NL with medical electron accelerators

    International Nuclear Information System (INIS)

    Rassow, Juergen; Stecher-Rasmussen, Finn; Voorbraak, Wim; Moss, Ray; Vroegindeweij, Corine; Hideghety, Katalin; Sauerwein, Wolfgang

    2001-01-01

    Background and purpose: The European Council Directive on health protection 97/43/EURATOM requires radiotherapy quality assurance programmes for performance and safety characteristics including acceptance and repeated tests. For Boron Neutron Capture therapy (BNCT) at the High Flux Reactor (HFR) in Petten/NL such a programme has been developed on the basis of IEC publications for medical electron accelerators. Results: The fundamental differences of clinical dosimetry for medical electron accelerators and BNCT are presented and the order of magnitude of dose components and their stability and that of the main other influencing parameter 10 B concentration for BNCT patient treatments. A comparison is given for requirements for accelerators and BNCT units indicating items which are not transferable, equal or additional. Preliminary results of in vivo measurements done with a set of 55 Mn, 63 Cu and 197 Au activation foils for all single fields for the four fractions at all 15 treated patients show with <±4% up to now a worse reproducibility than the used dose monitoring systems (±1.5%) caused by influence of hair position on the foil-skull distance. Conclusions: Despite the more complex clinical dosimetry (because of four relevant dose components, partly of different linear energy transfer (LET)) BNCT can be regulated following the principles of quality assurance procedures for therapy with medical electron accelerators. The reproducibility of applied neutron fluence (proportional to absorbed doses) and the main safety aspects are equal for all teletherapy methods including BNCT

  16. Control room lay-out

    International Nuclear Information System (INIS)

    Toma, Violeta

    2004-01-01

    TRIUMF (Tri-University Meson Facility) is Canada's national laboratory for particle and nuclear physics. There are 6 accelerators and 3 Control Rooms at TRIUMF. The main control room serves the big cyclotron, the 500 MeV, and the adjacent experiment. The 42 MeV and two 32 MeV ones are production dedicated. These cyclotrons belong to a private company but are operated by TRIUMF staff from ATG (Applied Technology Group) Control Room. The last is ISAC (Isotope Acceleration and Separation) Control Room, from which the LINAC is controlled. Research areas cover theoretical (2 subjects), pure (5 subjects) and applied (8 subjects) physics. In the early '70s, as the 500 MeV was being completed, the first Control Room was built in the main accelerator building. The recent topics covered by this paper are proton and pion therapy, what are the operator's duties?, the CP42, TR30 and TR13 cyclotron control rooms, the ISAC control systems including control room modification. Due to the nature of an operator's job, the Control Room layout is pretty important. This is true for any work environment, but when working shifts it becomes essential. Lots of time and effort, not to mention money, were spent to figure out the optimum configuration. It seems to me that the key factor in the control room layout is versatility, and this is because it has to keep happy a group of people with different inclinations, which have a tendency to become quite moody after the second night shift. No matter what, there will still be unhappy people, but we are trying our best. (Y. Tanaka)

  17. Reevaluation of photon activation yields of {sup 11}C. {sup 13}N, and {sup 15}O for the estimation of activity in gas and water induced by the operation of electron accelerates for medical use

    Energy Technology Data Exchange (ETDEWEB)

    Masumoto, Kazuyoshi; Matsumura, Hiroshi; Bessho, Kotaro; Toyoda, Akihiro [High Energy Accelerator Research Organization, Tsukuba (Japan); Kasako, Kazuaki [Shimizu Corporation, Tokyo (Japan)

    2016-09-15

    Activation of air and water in the electron linear accelerator for medical use has not been considered severely. By the new Japanese regulation for protection of radiation hazard, it became indispensable to evaluate of activation of air and water in the accelerator room. The measurement of induced activity in air and water components in the electron energy region of 10 to 20 MeV is very difficult, because this energy region is close to the threshold energy region of photonuclear reactions. Then, we measured the photonuclear reaction yields of {sup 13}N,{sup 15}O, and {sup 11}C by using the electron linear accelerator. Obtained data were compared with the data calculated by the Monte Carlo method. An activation experiment was performed at the Research Center for Electron Photon Science, Tohoku University. Highly purified SiO{sub 2}, Si{sub 3}N{sub 4}, and carbon disks were irradiated for 10 minutes by Bremsstrahlung converted by a tungsten plate. Induced activity from C, N, and O was obtained. Monte Carlo calculation was performed using MCNP5 and AERY (DCHAIN-SP) to simulate the experimental condition. Cross section data were adopted the KAERI dataset. In our experiment in hospital, calculated values were not agreed with experimental values. It might be three possible reasons as the cause of this deference, such as irradiation energy, calculation procedure and cross section data. Obtained data of this work, calculated and experimental values were good agreement with each other within one order. In this work, we used KAERI dataset of photonuclear reaction instead of JENDL. Therefore, it was found that the photonuclear cross section data of light elements are most important for yield calculation in these reactions. Further improvement for calculation using a new dataset JENDL/PD-2015 and considering electron energy spreading will be needed.

  18. Accelerators for Medicine

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    This lecture will review the different applications of particle accelerators to the medical field, from cancer treatment with beams of accelerator-produced particles (photons, electrons, protons, ions and neutrons) to the generation of radioactive isotopes used in medical diagnostics, in cancer therapy and in the new domain of theragnostics. For each application will be outlined the state of the art, the potential, and the accelerator challenges to be faced to meet the increasing demand for therapeutic procedures based on accelerators.

  19. SU-F-E-18: Training Monthly QA of Medical Accelerators: Illustrated Instructions for Self-Learning

    Energy Technology Data Exchange (ETDEWEB)

    Court, L; Wang, H; Aten, D; Chi, P; Gao, S; Aristophanous, M; Balter, P [UT MD Anderson Cancer Center, Houston, TX (United States); Brown, D; Yock, A [University of California, San Diego, La Jolla, CA (United States); Maddox, B [Brigham & Women’s Hospital, Boston, MA (United States); MacGregor, H [University of Cape Town (South Africa)

    2016-06-15

    Purpose: To develop and test clear illustrated instructions for training of monthly mechanical QA of medical linear accelerators. Methods: Illustrated instructions were created for monthly mechanical QA with tolerance tabulated, and underwent several steps of review and refinement. Testers with zero QA experience were then recruited from our radiotherapy department (1 student, 2 computational scientists and 8 dosimetrists). The following parameters were progressively de-calibrated on a Varian C-series linac: Group A = gantry angle, ceiling laser position, X1 jaw position, couch longitudinal position, physical graticule position (5 testers); Group B = Group A + wall laser position, couch lateral and vertical position, collimator angle (3 testers); Group C = Group B + couch angle, wall laser angle, and optical distance indicator (3 testers). Testers were taught how to use the linac, and then used the instructions to try to identify these errors. A physicist observed each session, giving support on machine operation, as necessary. The instructions were further tested with groups of therapists, graduate students and physics residents at multiple institutions. We have also changed the language of the instructions to simulate using the instructions with non-English speakers. Results: Testers were able to follow the instructions. They determined gantry, collimator and couch angle errors within 0.4, 0.3, and 0.9degrees of the actual changed values, respectively. Laser positions were determined within 1mm, and jaw positions within 2mm. Couch position errors were determined within 2 and 3mm for lateral/longitudinal and vertical errors, respectively. Accessory positioning errors were determined within 1mm. ODI errors were determined within 2mm when comparing with distance sticks, and 6mm when using blocks, indicating that distance sticks should be the preferred approach for inexperienced staff. Conclusion: Inexperienced users were able to follow these instructions, and catch

  20. SU-F-E-18: Training Monthly QA of Medical Accelerators: Illustrated Instructions for Self-Learning

    International Nuclear Information System (INIS)

    Court, L; Wang, H; Aten, D; Chi, P; Gao, S; Aristophanous, M; Balter, P; Brown, D; Yock, A; Maddox, B; MacGregor, H

    2016-01-01

    Purpose: To develop and test clear illustrated instructions for training of monthly mechanical QA of medical linear accelerators. Methods: Illustrated instructions were created for monthly mechanical QA with tolerance tabulated, and underwent several steps of review and refinement. Testers with zero QA experience were then recruited from our radiotherapy department (1 student, 2 computational scientists and 8 dosimetrists). The following parameters were progressively de-calibrated on a Varian C-series linac: Group A = gantry angle, ceiling laser position, X1 jaw position, couch longitudinal position, physical graticule position (5 testers); Group B = Group A + wall laser position, couch lateral and vertical position, collimator angle (3 testers); Group C = Group B + couch angle, wall laser angle, and optical distance indicator (3 testers). Testers were taught how to use the linac, and then used the instructions to try to identify these errors. A physicist observed each session, giving support on machine operation, as necessary. The instructions were further tested with groups of therapists, graduate students and physics residents at multiple institutions. We have also changed the language of the instructions to simulate using the instructions with non-English speakers. Results: Testers were able to follow the instructions. They determined gantry, collimator and couch angle errors within 0.4, 0.3, and 0.9degrees of the actual changed values, respectively. Laser positions were determined within 1mm, and jaw positions within 2mm. Couch position errors were determined within 2 and 3mm for lateral/longitudinal and vertical errors, respectively. Accessory positioning errors were determined within 1mm. ODI errors were determined within 2mm when comparing with distance sticks, and 6mm when using blocks, indicating that distance sticks should be the preferred approach for inexperienced staff. Conclusion: Inexperienced users were able to follow these instructions, and catch

  1. Development and characterization of an interferometer for calorimeter-based absorbed dose to water measurements in a medical linear accelerator.

    Science.gov (United States)

    Flores-Martinez, Everardo; Malin, Martha J; DeWerd, Larry A

    2016-11-01

    The quantity of relevance for external beam radiotherapy is absorbed dose to water (ADW). An interferometer was built, characterized, and tested to measure ADW within the dose range of interest for external beam radiotherapy using the temperature dependence of the refractive index of water. The interferometer was used to measure radiation-induced phase shifts of a laser beam passing through a (10 × 10 × 10) cm 3 water-filled glass phantom, irradiated with a 6 MV photon beam from a medical linear accelerator. The field size was (7 × 7) cm 2 and the dose was measured at a depth of 5 cm in the water phantom. The intensity of the interference pattern was measured with a photodiode and was used to calculate the time-dependent phase shift curve. The system was thermally insulated to achieve temperature drifts of less than 1.5 mK/min. Data were acquired 60 s before and after the irradiation. The radiation-induced phase shifts were calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. For 200, 300, and 400 monitor units, the measured doses were 1.6 ± 0.3, 2.6 ± 0.3, and 3.1 ± 0.3 Gy, respectively. Measurements agreed within the uncertainty with dose calculations performed with a treatment planning system. The estimated type-A, k = 1 uncertainty in the measured doses was 0.3 Gy which is an order of magnitude lower than previously published interferometer-based ADW measurements.

  2. Monte Carlo Investigation of Photon Beam Characteristics and its Variation with Incident Electron Beam Parameters for Indigenous Medical Linear Accelerator.

    Science.gov (United States)

    Mishra, Subhalaxmi; Dixit, P K; Selvam, T Palani; Yavalkar, Sanket S; Deshpande, D D

    2018-01-01

    A Monte Carlo model of a 6 MV medical linear accelerator (linac) unit built indigenously was developed using the BEAMnrc user code of the EGSnrc code system. The model was benchmarked against the measurements. Monte Carlo simulations were carried out for different incident electron beam parameters in the study. Simulation of indigenously developed linac unit has been carried out using the Monte Carlo based BEAMnrc user-code of the EGSnrc code system. Using the model, percentage depth dose (PDD), and lateral dose profiles were studied using the DOSXYZnrc user code. To identify appropriate electron parameters, three different distributions of electron beam intensity were investigated. For each case, the kinetic energy of the incident electron was varied from 6 to 6.5 MeV (0.1 MeV increment). The calculated dose data were compared against the measurements using the PTW, Germany make RFA dosimetric system (water tank MP3-M and 0.125 cm 3 ion chamber). The best fit of incident electron beam parameter was found for the combination of beam energy of 6.2 MeV and circular Gaussian distributed source in X and Y with FWHM of 1.0 mm. PDD and beam profiles (along both X and Y directions) were calculated for the field sizes from 5 cm × 5 cm to 25 cm × 25 cm. The dose difference between the calculated and measured PDD and profile values were under 1%, except for the penumbra region where the maximum deviation was found to be around 2%. A Monte Carlo model of indigenous linac (6 MV) has been developed and benchmarked against the measured data.

  3. SU-F-T-213: Commissioning Results of the Prototype Active Scanning Irradiation System of Korea Heavy Ion Medical Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kim, C; Seduk, J; Yang, T [Korea Institute of Radiological And Medical Sciences, Seoul, Seoul (Korea, Republic of)

    2016-06-15

    Purpose: A prototype actives scanning beam delivery system was designed, manufactured and installed as a part of the Korea Heavy Ion Medical Accelerator Project. The prototype system includes the most components for steering, modulating, detecting incident beam to patient. The system was installed in MC-50 cyclotron beam line and tested to extract the normal operation conditions. Methods: The commissioning process was completed by using 45 MeV of proton beam. To measure the beam position accuracy along the scanning magnet power supply current, 25 different spots were scanning and measured. The scanning results on GaF film were compared with the irradiation plan. Also, the beam size variation and the intensity reduction using range shifter were measured and analyzed. The results will be used for creating a conversion factors for asymmetric behavior of scanning magnets and a dose compensation factor for longitudinal direction. Results: The results show asymmetry operations on both scanning × and y magnet. In case of scanning magnet × operation, the current to position conversion factors were measured 1.69 mm/A for positive direction and 1.74 mm/A for negative direction. The scanning magnet y operation shows 1.38mm/A and 1.48 mm/A for both directions. The size of incoming beam which was 18 mm as sigma becomes larger up to 55 mm as sigma while using 10 mm of the range shifter plate. As the beam size becomes large, the maximum intensity of the was decreased. In case of using 10 mm of range shifter, the maximum intensity was only 52% compared with no range shifter insertion. Conclusion: For the appropriate operation of the prototype active scanning system, the commissioning process were performed to measure the beam characteristics variation. The obtained results would be applied on the irradiation planning software for more precise dose delivery using the active scanning system.

  4. Modeling of electron beams produced by linear accelerator installed at CNSTN / optimization study for the case of radiation sterilization of medical products and pharmaceutical

    International Nuclear Information System (INIS)

    Jellikh, Jihed

    2011-01-01

    The evolution of particle accelerators has led to the disposal of a very wide diversity of applications, such as the technique of treatment with Beta radiations. an electron accelerator has been installed at the National Center for nuclear Sciences and Technologies CNSTN) with the aim of controlling this technology, its development and its use in the areas of agriculture, industry, human health and scientific research. this project is committed for the study of the exploitation of this new facility in the field of radio-sterilization of medical, pharmaceuticals, cosmetics and laboratory products. A numerical tool has been then developed to simulate the radio processing and to simplify this process. Due to this option of dose distribution modeling inside a studied product, it's possible to estimate the best configuration for the accelerator parameter setting. It is a solution allowing to guarantee at once the conformity of the treatment of a product, as well as the reliability of the installation.

  5. Creators Room

    DEFF Research Database (Denmark)

    Iversholt, Lene; Iversholt Toft, Karina

    2012-01-01

    Creators Room er et koncept til daginsitutioner, der indrammer og giver bud på en forståelse mellem inkluderende pædagogik og fysiske rammer. Konceptet er udviklet i et tværfagligt procesforløb, hvor formålet har været at skabe stadig bedre indendørsmiljøer for børn ved at forene pædagogiske...

  6. CEBAF Control Room Renovation

    International Nuclear Information System (INIS)

    Michael Spata; Thomas Oren

    2005-01-01

    The Machine Control Center (MCC) at Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) was initially constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facility's 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve workflow processes and ergonomic attributes. This effort also sets the foundation for the redevelopment of the accelerator's control system to deliver high reliability performance with improvements in beam specifications management and information flow. The complete renovation was performed over a three-week maintenance period with no interruption to beam operations. We present the results of this effort

  7. CEBAF Control Room Renovation

    International Nuclear Information System (INIS)

    Michael Spata; Thomas Oren

    2005-01-01

    The Machine Control Center at Jefferson Lab's Continuous Electron Beam Accelerator Facility was initially constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facilities 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve on workflow processes and ergonomic attributes. This effort also sets the foundation for the redevelopment of the accelerator's control system to deliver high reliability performance with improvements in beam specifications management and information flow. The complete renovation was performed over a three-week period with no interruption to beam operations. We present the results of this effort

  8. Design Considerations and Validation of Tenth Value Layer Used for a Medical Linear Accelerator Bunker Using High Density Concrete

    International Nuclear Information System (INIS)

    Peet, Deborah; Horton, Patrick; Jones, Matthew; Ramsdale, Malcolm

    2006-01-01

    A bunker for the containment and medical use of 10 MV and 6 MV X-rays from a linear accelerator was designed to be added on to four existing bunkers. Space was limited and the walls of the bunker were built using Magnadense, a high density aggregate mined in Sweden and imported into the UK by Minelco Minerals Ltd. The density was specified by the user to be a minimum of 3800 kg/m 3 . This reduced the thickness of primary and secondary shielding over that required using standard concrete. Standard concrete (density 2350 kg/m 3 ) was used for the roof of the bunker. No published data for the tenth value layer (T.V.L.) of the high density concrete were available and values of T.V.L. were derived from those for standard concrete using the ratio of density. Calculations of wall thickness along established principles using normal assumptions and dose constraints resulted in a design with minimum primary wall barriers of 1500 mm and secondary barriers of between 800 mm and 1000 mm of high density concrete. Following construction, measurements were made of the dose rates outside the shielding thereby allowing estimates of the T.V.L. of the material for 6 and 10 MV X-rays. The instantaneous dose rates outside the primary barrier walls were calculated to be less than 6 x 10 -6 Sv/hr but on measurement were found to be more than a factor of 4 times lower than this. Calculations were reviewed and the T.V.L. was found to be 12% greater than that required to achieve the measured dose rate. On the roof, the instantaneous dose rate at the primary barrier was measured to be within 3% of that predicted using the published values of T.V.L. for standard concrete. Sample cubes of standard and high density concrete poured during construction showed that the density of the standard concrete in the roof was close to that used in the design whereas the physical density of Magnadense concrete was on average 5% higher than that specified. In conclusion, values of T.V.L. for the high density

  9. Decision support using anesthesia information management system records and accreditation council for graduate medical education case logs for resident operating room assignments.

    Science.gov (United States)

    Wanderer, Jonathan P; Charnin, Jonathan; Driscoll, William D; Bailin, Michael T; Baker, Keith

    2013-08-01

    Our goal in this study was to develop decision support systems for resident operating room (OR) assignments using anesthesia information management system (AIMS) records and Accreditation Council for Graduate Medical Education (ACGME) case logs and evaluate the implementations. We developed 2 Web-based systems: an ACGME case-log visualization tool, and Residents Helping in Navigating OR Scheduling (Rhinos), an interactive system that solicits OR assignment requests from residents and creates resident profiles. Resident profiles are snapshots of the cases and procedures each resident has done and were derived from AIMS records and ACGME case logs. A Rhinos pilot was performed for 6 weeks on 2 clinical services. One hundred sixty-five requests were entered and used in OR assignment decisions by a single attending anesthesiologist. Each request consisted of a rank ordered list of up to 3 ORs. Residents had access to detailed information about these cases including surgeon and patient name, age, procedure type, and admission status. Success rates at matching resident requests were determined by comparing requests with AIMS records. Of the 165 requests, 87 first-choice matches (52.7%), 27 second-choice matches (16.4%), and 8 third-choice matches (4.8%) were made. Forty-three requests were unmatched (26.1%). Thirty-nine first-choice requests overlapped (23.6%). Full implementation followed on 8 clinical services for 8 weeks. Seven hundred fifty-four requests were reviewed by 15 attending anesthesiologists, with 339 first-choice matches (45.0%), 122 second-choice matches (16.2%), 55 third-choice matches (7.3%), and 238 unmatched (31.5%). There were 279 overlapping first-choice requests (37.0%). The overall combined match success rate was 69.4%. Separately, we developed an ACGME case-log visualization tool that allows individual resident experiences to be compared against case minimums as well as resident peer groups. We conclude that it is feasible to use ACGME case

  10. Accelerator-based BNCT.

    Science.gov (United States)

    Kreiner, A J; Baldo, M; Bergueiro, J R; Cartelli, D; Castell, W; Thatar Vento, V; Gomez Asoia, J; Mercuri, D; Padulo, J; Suarez Sandin, J C; Erhardt, J; Kesque, J M; Valda, A A; Debray, M E; Somacal, H R; Igarzabal, M; Minsky, D M; Herrera, M S; Capoulat, M E; Gonzalez, S J; del Grosso, M F; Gagetti, L; Suarez Anzorena, M; Gun, M; Carranza, O

    2014-06-01

    The activity in accelerator development for accelerator-based BNCT (AB-BNCT) both worldwide and in Argentina is described. Projects in Russia, UK, Italy, Japan, Israel, and Argentina to develop AB-BNCT around different types of accelerators are briefly presented. In particular, the present status and recent progress of the Argentine project will be reviewed. The topics will cover: intense ion sources, accelerator tubes, transport of intense beams, beam diagnostics, the (9)Be(d,n) reaction as a possible neutron source, Beam Shaping Assemblies (BSA), a treatment room, and treatment planning in realistic cases. © 2013 Elsevier Ltd. All rights reserved.

  11. SU-F-T-475: An Evaluation of the Overlap Between the Acceptance Testing and Commissioning Processes for Conventional Medical Linear Accelerators

    International Nuclear Information System (INIS)

    Morrow, A; Rangaraj, D; Perez-Andujar, A; Krishnamurthy, N

    2016-01-01

    Purpose: This work’s objective is to determine the overlap of processes, in terms of sub-processes and time, between acceptance testing and commissioning of a conventional medical linear accelerator and to evaluate the time saved by consolidating the two processes. Method: A process map for acceptance testing for medical linear accelerators was created from vendor documentation (Varian and Elekta). Using AAPM TG-106 and inhouse commissioning procedures, a process map was created for commissioning of said accelerators. The time to complete each sub-process in each process map was evaluated. Redundancies in the processes were found and the time spent on each were calculated. Results: Mechanical testing significantly overlaps between the two processes - redundant work here amounts to 9.5 hours. Many beam non-scanning dosimetry tests overlap resulting in another 6 hours of overlap. Beam scanning overlaps somewhat - acceptance tests include evaluating PDDs and multiple profiles but for only one field size while commissioning beam scanning includes multiple field sizes and depths of profiles. This overlap results in another 6 hours of rework. Absolute dosimetry, field outputs, and end to end tests are not done at all in acceptance testing. Finally, all imaging tests done in acceptance are repeated in commissioning, resulting in about 8 hours of rework. The total time overlap between the two processes is about 30 hours. Conclusion: The process mapping done in this study shows that there are no tests done in acceptance testing that are not also recommended to do for commissioning. This results in about 30 hours of redundant work when preparing a conventional linear accelerator for clinical use. Considering these findings in the context of the 5000 linacs in the United states, consolidating acceptance testing and commissioning would have allowed for the treatment of an additional 25000 patients using no additional resources.

  12. SU-F-T-475: An Evaluation of the Overlap Between the Acceptance Testing and Commissioning Processes for Conventional Medical Linear Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Morrow, A [Scott & White Hospital Temple, TX (United States); Rangaraj, D [Baylor Scott & White Health, Temple, TX (United States); Perez-Andujar, A [University of California San Francisco, San Francisco, CA (United States); Krishnamurthy, N [Baylor Scott & White Healthcare, Temple, TX (United States)

    2016-06-15

    Purpose: This work’s objective is to determine the overlap of processes, in terms of sub-processes and time, between acceptance testing and commissioning of a conventional medical linear accelerator and to evaluate the time saved by consolidating the two processes. Method: A process map for acceptance testing for medical linear accelerators was created from vendor documentation (Varian and Elekta). Using AAPM TG-106 and inhouse commissioning procedures, a process map was created for commissioning of said accelerators. The time to complete each sub-process in each process map was evaluated. Redundancies in the processes were found and the time spent on each were calculated. Results: Mechanical testing significantly overlaps between the two processes - redundant work here amounts to 9.5 hours. Many beam non-scanning dosimetry tests overlap resulting in another 6 hours of overlap. Beam scanning overlaps somewhat - acceptance tests include evaluating PDDs and multiple profiles but for only one field size while commissioning beam scanning includes multiple field sizes and depths of profiles. This overlap results in another 6 hours of rework. Absolute dosimetry, field outputs, and end to end tests are not done at all in acceptance testing. Finally, all imaging tests done in acceptance are repeated in commissioning, resulting in about 8 hours of rework. The total time overlap between the two processes is about 30 hours. Conclusion: The process mapping done in this study shows that there are no tests done in acceptance testing that are not also recommended to do for commissioning. This results in about 30 hours of redundant work when preparing a conventional linear accelerator for clinical use. Considering these findings in the context of the 5000 linacs in the United states, consolidating acceptance testing and commissioning would have allowed for the treatment of an additional 25000 patients using no additional resources.

  13. Shielding evaluation of a medical linear accelerator vault in preparation for installing a high-dose rate 252Cf remote after-loader

    International Nuclear Information System (INIS)

    Melhus, C. S.; Rivard, M. J.; KurKomelis, J.; Liddle, C. B.; Masse, F. X.

    2005-01-01

    In support of the effort to begin high-dose rate 252 Cf brachytherapy treatments at Tufts-New England Medical Center, the shielding capabilities of a clinical accelerator vault against the neutron and photon emissions from a 1.124 mg 252 Cf source were examined. Outside the clinical accelerator vault, the fast neutron dose equivalent rate was below the lower limit of detection of a CR-39 etched track detector and below 0.14 ± 0.02 μSv h -1 with a proportional counter, which is consistent, within the uncertainties, with natural background. The photon dose equivalent rate was also measured to be below background levels (0.1 μSv h -1 ) using an ionisation chamber and an optically stimulated luminescence dosemeter. A Monte Carlo simulation of neutron transport through the accelerator vault was performed to validate measured values and determine the thermal-energy to low-energy neutron component. Monte Carlo results showed that the dose equivalent rate from fast neutrons was reduced by a factor of 100,000 after attenuation through the vault wall, and the thermal-energy neutron dose equivalent rate would be an additional factor of 1000 below that of the fast neutrons. Based on these findings, the shielding installed in this facility is sufficient for the use of at least 5.0 mg of 252 Cf. (authors)

  14. CEBAF Control Room Renovation

    International Nuclear Information System (INIS)

    Michael Spata; Anthony Cuffe; Thomas Oren

    2005-01-01

    The Machine Control Center (MCC) at Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) was constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facilities 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve on work-flow processes and ergonomic attributes. The renovation was performed in two phases during the summer of 2004, with one phase occurring during machine operations and the latter, more extensive phase, occurring during our semi-annual shutdown period. The new facility takes advantage of advances in display technology, analog and video signal management, server technology, ergonomic workspace design, lighting engineering, acoustic ceilings and raised flooring solutions to provide a marked improvement in the overall environment of machine operations

  15. Measurements of the relative backscatter contribution to the monitor chamber for modern medical linear accelerators; A multi-center study

    DEFF Research Database (Denmark)

    Sibolt, Patrik; Cronholm, Rickard O.; Beierholm, Anders Ravnsborg

    2015-01-01

    Conversion to absolute dose in Monte Carlo (MC) simulations of MV radiotherapy beams needs correct modeling of backscatter (BS) to the linear accelerator (linac) monitor chamber. For some linacs the BS depends largely on jaw settings. The backscattered fraction (BSF) of radiation can be determined...... BSF measurements were compared with MC simulations performed using the BEAMnrc user code. For flattened beams on the Varian linacs, the measured BSF exhibited a clear linear correlation with square jaw settings (correlation coefficient r > 0.9 with p

  16. The electron accelerator Ridgetron

    International Nuclear Information System (INIS)

    Hayashizaki, N.; Hattori, T.; Odera, M.; Fujisawa, T.

    1999-01-01

    Many electron accelerators of DC or RF type have been widely used for electron beam irradiation (curing, crosslinking of polymers, sterilization of medical disposables, preservation of food, etc.). Regardless of the acceleration energy, the accelerators to be installed in industrial facilities, have to satisfy the requires of compact size, low power consumption and stable operation. The DC accelerator is realized very compact in the energy under 300 keV, however, it is large to prevent the discharge of an acceleration column in the energy over 300 keV. The RF electron accelerator Ridgetron has been developed to accelerate the continuous beam of the 0.5-10 MeV range in compact space. It is the first example as an electron accelerator incorporated a ridged RF cavity. A prototype system of final energy of 2.5 MeV has been studied to confirm the feasibility at present

  17. Particle accelerators in the Czech lands

    International Nuclear Information System (INIS)

    Janovsky, I.

    2007-01-01

    The paper is structured as follows: A short look into history of accelerators; Particle accelerators in the Czech lands (Accelerators at the Institute of Nuclear Physics; Accelerators at the Faculty of Mathematics and Physics, Charles University; Czechoslovak betatron, accelerators for non-destructive testing and radiotherapy; Czechoslovak high-frequency linear electron accelerator; Czechoslovak-Soviet microtron; Accelerators at the State Research Institute of Textiles; Accelerators at the Kablo Vrchlabi plant; and Cyclotrons in the medical sector. (P.A.)

  18. Measurement of the neutron spectrum in a room with an accelerator Varian 2300C/D Linac using the Bonner multisphere spectrometer; Medicao do espectro de neutrons em uma sala com um acelerador Varian 2300C/D Linav usando o espectrometro de multiesferas de Bonner

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcante, D.B.S., E-mail: cavalcante@ird.gov.b [Universidade Federal do Rio de Janeiro (IF/UFRJ), RJ (Brazil). Inst. de Fisica; Fonseca, E.S. da, E-mail: evaldo@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Lemos Junior, R.M. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil); Batista, D.V.S. [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The generated neutron field varies considerably and depends on the beam energy, on the shielding of the accelerator, on the filters for beam homogeneity, and also on the mobile collimators and geometry of irradiation. The estimation of the component relative to the photoneutrons has practical interest for evaluation of the radiological risks for the workers and for the patient as well. Due to the high frequency magnetic field, and to the photon abundance resulting of the escape and scattering at treatment room, those measurements present some difficulties. Measurements of the neutron fields can be made with a Bonner spectrometer. Those system was calibrated with referred neutron standard sources and used for make measurements on a spot of the room where a Variant 2300C/D Linac is installed. The unfolding process used the BUNKI computer code for determination of the neutron spectra at the measurement spot

  19. Industrial Application of Accelerators

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    At CERN, we are very familiar with large, high energy particle accelerators. However, in the world outside CERN, there are more than 35000 accelerators which are used for applications ranging from treating cancer, through making better electronics to removing harmful micro-organisms from food and water. These are responsible for around $0.5T of commerce each year. Almost all are less than 20 MeV and most use accelerator types that are somewhat different from what is at CERN. These lectures will describe some of the most common applications, some of the newer applications in development and the accelerator technology used for them. It will also show examples of where technology developed for particle physics is now being studied for these applications. Rob Edgecock is a Professor of Accelerator Science, with a particular interest in the medical applications of accelerators. He works jointly for the STFC Rutherford Appleton Laboratory and the International Institute for Accelerator Applications at the Univer...

  20. Industrial Application of Accelerators

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    At CERN, we are very familiar with large, high energy particle accelerators. However, in the world outside CERN, there are more than 35000 accelerators which are used for applications ranging from treating cancer, through making better electronics to removing harmful micro-organisms from food and water. These are responsible for around $0.5T of commerce each year. Almost all are less than 20 MeV and most use accelerator types that are somewhat different from what is at CERN. These lectures will describe some of the most common applications, some of the newer applications in development and the accelerator technology used for them. It will also show examples of where technology developed for particle physics is now being studied for these applications. Rob Edgecock is a Professor of Accelerator Science, with a particular interest in the medical applications of accelerators. He works jointly for the STFC Rutherford Appleton Laboratory and the International Institute for Accelerator Applications at the Uni...

  1. New concept on an integrated interior magnetic resonance imaging and medical linear accelerator system for radiation therapy.

    Science.gov (United States)

    Jia, Xun; Tian, Zhen; Xi, Yan; Jiang, Steve B; Wang, Ge

    2017-01-01

    Image guidance plays a critical role in radiotherapy. Currently, cone-beam computed tomography (CBCT) is routinely used in clinics for this purpose. While this modality can provide an attenuation image for therapeutic planning, low soft-tissue contrast affects the delineation of anatomical and pathological features. Efforts have recently been devoted to several MRI linear accelerator (LINAC) projects that lead to the successful combination of a full diagnostic MRI scanner with a radiotherapy machine. We present a new concept for the development of the MRI-LINAC system. Instead of combining a full MRI scanner with the LINAC platform, we propose using an interior MRI (iMRI) approach to image a specific region of interest (RoI) containing the radiation treatment target. While the conventional CBCT component still delivers a global image of the patient's anatomy, the iMRI offers local imaging of high soft-tissue contrast for tumor delineation. We describe a top-level system design for the integration of an iMRI component into an existing LINAC platform. We performed numerical analyses of the magnetic field for the iMRI to show potentially acceptable field properties in a spherical RoI with a diameter of 15 cm. This field could be shielded to a sufficiently low level around the LINAC region to avoid electromagnetic interference. Furthermore, we investigate the dosimetric impacts of this integration on the radiotherapy beam.

  2. Accelerator business in Japan expanding

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Accelerators have become to be used increasingly in Japan in such fields as medicine, physics research and industry. This has caused stiff competition for market share by the manufacturers of accelerators. Electron beam accelerators for industrial use provide an indispensable means for adding values to products, for example, electric cables with incombustible insulators. Linear accelerators for the nondestructive inspection of nuclear components have been widely installed at equipment manufacturing plants. Active efforts have been exerted to develop small synchrotron radiation accelerators for next generation electronic industry. Cyclotrons for producing short life radioisotopes for medical diagnosis and electron beam accelerators for radiation therapy are also used routinely. The suppliers of accelerators include the companies manufacturing heavy electric machinery, heavy machinery and the engineering division of steelmakers. Accelerator physics is being formed, but universities do not yet offer the course regarding accelerators. Accelerator use in Japan and the trend of accelerator manufacturers are reported. (K.I.)

  3. Main of probabilistic safety assessment (PSA) of the radiotherapy treatment process with a linear accelerator for medical purposes (linac)

    International Nuclear Information System (INIS)

    Vilaragut Llanes, Juan Jose; Fernandez, Ruben Ferro; Ortiz Lopez, Pedro

    2009-01-01

    The radiation safety assessments traditionally have been based on analyzing the lessons you learn of new events that are becoming known. Although these methods are very valuable, their main limitation is that only cover known events and leave without consider other possible failures that have occurred or have not been published, This does not mean they can not occur. Other tools to analyze prospectively the safety, among which found Probabilistic Safety Assessment (PSA). This paper summarizes the project of American Forum of agencies radiological and nuclear regulators aimed at applying the methods of APS treatment process with a linear accelerator. We defined as unintended consequences accidental exposures both single patient and multiple patients. FMEA methodology was used to define events initiators of accidents and methods of event trees and trees failure to identify the accident sequences that may occur. A Once quantified the frequency of occurrence of accidental sequences Analyses of importance in determining the most recent events significant from the point of view of safety. We identified 158 of equipment failure modes and 295 errors human if they occurred would have the potential to cause the accidental exposures defined. We studied 118 of initiating events accident and 120 barriers. We studied 434 accident sequences. The accidental exposure of a single patient were 40 times likely that multiple patients. 100% of the total frequency of accidental exposures on a single patient is caused by human errors . 8% of the total frequency of accidental exposures on multiple patients initiating events may occur by equipment failure (Computerized tomography, treatment planning system, throttle linear) and 92% by human error. As part of the and recommendations of the study presents the events that are more contribution on the reduction of risk of accidental exposure. (author)

  4. Hotel room suicide.

    Science.gov (United States)

    Zarkowski, Paul; Avery, David

    2006-10-01

    The objective of our research was to quantify the increased risk of suicide associated with registering in local hotels/motels. Medical examiner case files of suicide in King County, Washington, were reviewed for years 2002-2004. The incidence of suicide in local residents registering in local hotels/motels was 223/100,000 which is significantly greater than the incidence of suicide in the general population of King County (11.7/100,000 p Hotel/motel guests from outside Washington had a significantly reduced incidence of suicide (3.9/100,000 p = 0.002). The study results suggest that there is an increased risk of suicide in local residents who register in local hotel rooms.

  5. Radiation protection in the operating room

    International Nuclear Information System (INIS)

    Kunz, B.; Stargardt, A.

    1978-01-01

    On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low

  6. Can Accelerators Accelerate Learning?

    International Nuclear Information System (INIS)

    Santos, A. C. F.; Fonseca, P.; Coelho, L. F. S.

    2009-01-01

    The 'Young Talented' education program developed by the Brazilian State Funding Agency (FAPERJ)[1] makes it possible for high-schools students from public high schools to perform activities in scientific laboratories. In the Atomic and Molecular Physics Laboratory at Federal University of Rio de Janeiro (UFRJ), the students are confronted with modern research tools like the 1.7 MV ion accelerator. Being a user-friendly machine, the accelerator is easily manageable by the students, who can perform simple hands-on activities, stimulating interest in physics, and getting the students close to modern laboratory techniques.

  7. Can Accelerators Accelerate Learning?

    Science.gov (United States)

    Santos, A. C. F.; Fonseca, P.; Coelho, L. F. S.

    2009-03-01

    The 'Young Talented' education program developed by the Brazilian State Funding Agency (FAPERJ) [1] makes it possible for high-schools students from public high schools to perform activities in scientific laboratories. In the Atomic and Molecular Physics Laboratory at Federal University of Rio de Janeiro (UFRJ), the students are confronted with modern research tools like the 1.7 MV ion accelerator. Being a user-friendly machine, the accelerator is easily manageable by the students, who can perform simple hands-on activities, stimulating interest in physics, and getting the students close to modern laboratory techniques.

  8. Technology and applications of advanced accelerator concepts

    CERN Document Server

    Chou, Weiren

    2016-01-01

    Since its invention in the 1920s, particle accelerators have made tremendous progress in accelerator science, technology and applications. However, the fundamental acceleration principle, namely, to apply an external radiofrequency (RF) electric field to accelerate charged particles, remains unchanged. As this method (either room temperature RF or superconducting RF) is approaching its intrinsic limitation in acceleration gradient (measured in MeV/m), it becomes apparent that new methods with much higher acceleration gradient (measured in GeV/m) must be found for future very high energy accelerators as well as future compact (table-top or room-size) accelerators. This volume introduces a number of advanced accelerator concepts (AAC) — their principles, technologies and potential applications. For the time being, none of them stands out as a definitive direction in which to go. But these novel ideas are in hot pursuit and look promising. Furthermore, some AAC requires a high power laser system. This has the ...

  9. Revisiting the Operating Room Basics

    Directory of Open Access Journals (Sweden)

    Tushar Chakravorty

    2015-12-01

    Full Text Available Young doctors walking into the operating room are eager to develop their skills to become efficient and knowledgeable professionals in future. But precious little is done to actively develop the basic practical skills of the budding doctors. They remain unaware about the layout of the operating room, the OR etiquette and often do not have sound scientific understanding and importance of meticulous execution of the basic operating room protocols. This article stresses the need to develop the basics of OR protocol and to improve the confidence of the young doctor by strengthening his foundation by showing him that attention to the basics of medical care and empathy for the patient can really make a difference to the outcome of a treatment.

  10. The relationships between the use of self-regulated learning strategies and depression among medical students: an accelerated prospective cohort study.

    Science.gov (United States)

    Van Nguyen, Hung; Laohasiriwong, Wongsa; Saengsuwan, Jiamjit; Thinkhamrop, Bandit; Wright, Pamela

    2015-01-01

    We conducted this study to determine the relationships between the use of self-regulated learning strategies (SRL) and depression scores among medical students. An accelerated prospective cohort study among 623 students at a public medical university in Vietnam was carried out during the academic year 2012-2013. The Depression, Anxiety and Stress Scales (21 items) was used to measure depression scores as the primary research outcome, and to measure anxiety and stress scores as the confounding variables. Fourteen SRL subscales including intrinsic/extrinsic goal orientation, task value, self-efficacy for learning, control of learning beliefs, rehearsal, elaboration, organization, critical thinking, meta-cognitive strategies, time and study environment, effort regulation, peer learning, and help seeking were measured using the Motivated Strategies for Learning Questionnaire. Data were collected at two points in time (once each semester). There were 744 responses at the first time (95.88%) and 623 at time two (drop-out rate of 16.26%). The generalized estimating equation was applied to identify any relationships between the use of each SRL subscale and depression scores at time 2, adjusting for the effects of depression at time 1, anxiety, stress, within cluster correlation, and potential demographic covariates. Separate multivariate GEE analysis indicated that all SRL subscales were significantly negatively associated with depression scores, except for extrinsic goal orientation and peer learning. Whereas full multivariate GEE analysis revealed that self-efficacyT1, help-seekingT1, time and study environmentT2 were found to be significantly negatively associated with depressionT2, adjusting for the effects of depressionT1, anxiety, stress, and demographic covariates. The results should be used to provide appropriate support for medical students to reduce depression.

  11. IAE pulsed electrostatic accelerator

    International Nuclear Information System (INIS)

    Afanas'ev, V.P.; Ganzhelyuk, M.L.; Kozlov, L.D.; Koltypin, E.A.; Molchanov, Yu.D.; Otroshchenko, G.A.; Yan'kov, G.B.

    1976-01-01

    The modernized pulse electrostatic accelerator using the klystron ion grouping and the beam interruption system prior to acceleration is described. The accelerator is modernized in order to improve parameters of a current pulse and to decrease the background in the measurement room. The ion beam of needed dimensions is obtained with the help of a high-frequency source and a beam grouping and deflection system. The general view of the beam grouping and deflection system is shown. The ion beam forming process is considered in detail. The modernized electrostatic accelerator permits to obtain a pulse current with a pulse length of 1.5 ns and an amplitude of 1.5 - 2 μA. With the repetition frequency of 2 MHz, the average target current is about 6 μA

  12. Plasma accelerators

    International Nuclear Information System (INIS)

    Bingham, R.; Angelis, U. de; Johnston, T.W.

    1991-01-01

    Recently attention has focused on charged particle acceleration in a plasma by a fast, large amplitude, longitudinal electron plasma wave. The plasma beat wave and plasma wakefield accelerators are two efficient ways of producing ultra-high accelerating gradients. Starting with the plasma beat wave accelerator (PBWA) and laser wakefield accelerator (LWFA) schemes and the plasma wakefield accelerator (PWFA) steady progress has been made in theory, simulations and experiments. Computations are presented for the study of LWFA. (author)

  13. Use of lean and six sigma methodology to improve operating room efficiency in a high-volume tertiary-care academic medical center.

    Science.gov (United States)

    Cima, Robert R; Brown, Michael J; Hebl, James R; Moore, Robin; Rogers, James C; Kollengode, Anantha; Amstutz, Gwendolyn J; Weisbrod, Cheryl A; Narr, Bradly J; Deschamps, Claude

    2011-07-01

    Operating rooms (ORs) are resource-intense and costly hospital units. Maximizing OR efficiency is essential to maintaining an economically viable institution. OR efficiency projects often focus on a limited number of ORs or cases. Efforts across an entire OR suite have not been reported. Lean and Six Sigma methodologies were developed in the manufacturing industry to increase efficiency by eliminating non-value-added steps. We applied Lean and Six Sigma methodologies across an entire surgical suite to improve efficiency. A multidisciplinary surgical process improvement team constructed a value stream map of the entire surgical process from the decision for surgery to discharge. Each process step was analyzed in 3 domains, ie, personnel, information processed, and time. Multidisciplinary teams addressed 5 work streams to increase value at each step: minimizing volume variation; streamlining the preoperative process; reducing nonoperative time; eliminating redundant information; and promoting employee engagement. Process improvements were implemented sequentially in surgical specialties. Key performance metrics were collected before and after implementation. Across 3 surgical specialties, process redesign resulted in substantial improvements in on-time starts and reduction in number of cases past 5 pm. Substantial gains were achieved in nonoperative time, staff overtime, and ORs saved. These changes resulted in substantial increases in margin/OR/day. Use of Lean and Six Sigma methodologies increased OR efficiency and financial performance across an entire operating suite. Process mapping, leadership support, staff engagement, and sharing performance metrics are keys to enhancing OR efficiency. The performance gains were substantial, sustainable, positive financially, and transferrable to other specialties. Copyright © 2011 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  14. A method for estimation of accuracy of dose delivery with dynamic slit windows in medical linear accelerators

    International Nuclear Information System (INIS)

    Ravichandran, R.; Binukumar, J.P.; Sivakumar, S.S.; Krishnamurthy, K.; Davis, C.A.

    2008-01-01

    Intensity-modulated radiotherapy (IMRT) clinical dose delivery is based on computer-controlled multileaf movements at different velocities. To test the accuracy of modulation of the beam periodically, quality assurance (QA) methods are necessary. Using a cylindrical phantom, dose delivery was checked at a constant geometry for sweeping fields. Repeated measurements with an in-house designed methodology over a period of 1 year indicate that the method is very sensitive to check the proper functioning of such dose delivery in medical linacs. A cylindrical perspex phantom with facility to accurately position a 0.6- cc (FC 65) ion chamber at constant depth at isocenter, (SA 24 constancy check tool phantom for MU check, Scanditronix Wellhofer) was used. Dosimeter readings were integrated for 4-mm, 10-mm, 20-mm sweeping fields and for 3 angular positions of the gantry periodically. Consistency of standard sweeping field output (10-mm slit width) and the ratios of outputs against other slit widths over a long period were reported. A 10-mm sweeping field output was found reproducible within an accuracy of 0.03% (n = 25) over 1 year. Four-millimeter, 20-mm outputs expressed as ratio with respect to 10- mm sweep output remained within a mean deviation of 0.2% and 0.03% respectively. Outputs at 3 gantry angles remained within 0.5%, showing that the effect of dynamic movements of multileaf collimator (MLC) on the output is minimal for angular positions of gantry. This method of QA is very simple and is recommended in addition to individual patient QA measurements, which reflect the accuracy of dose planning system. In addition to standard output and energy checks of linacs, the above measurements can be complemented so as to check proper functioning of multileaf collimator for dynamic field dose delivery. (author)

  15. Linear Accelerators

    International Nuclear Information System (INIS)

    Vretenar, M

    2014-01-01

    The main features of radio-frequency linear accelerators are introduced, reviewing the different types of accelerating structures and presenting the main characteristics aspects of linac beam dynamics

  16. Improving operating room safety

    Directory of Open Access Journals (Sweden)

    Garrett Jill

    2009-11-01

    Full Text Available Abstract Despite the introduction of the Universal Protocol, patient safety in surgery remains a daily challenge in the operating room. This present study describes one community health system's efforts to improve operating room safety through human factors training and ultimately the development of a surgical checklist. Using a combination of formal training, local studies documenting operating room safety issues and peer to peer mentoring we were able to substantially change the culture of our operating room. Our efforts have prepared us for successfully implementing a standardized checklist to improve operating room safety throughout our entire system. Based on these findings we recommend a multimodal approach to improving operating room safety.

  17. Manipulative therapy in addition to usual medical care accelerates recovery of shoulder complaints at higher costs: economic outcomes of a randomized trial

    Directory of Open Access Journals (Sweden)

    Bergman Gert JD

    2010-09-01

    Full Text Available Abstract Background Shoulder complaints are common in primary care and have unfavourable long term prognosis. Our objective was to evaluate the clinical effectiveness of manipulative therapy of the cervicothoracic spine and the adjacent ribs in addition to usual medical care (UMC by the general practitioner in the treatment of shoulder complaints. Methods This economic evaluation was conducted alongside a randomized trial in primary care. Included were 150 patients with shoulder complaints and a dysfunction of the cervicothoracic spine and adjacent ribs. Patients were treated with UMC (NSAID's, corticosteroid injection or referral to physical therapy and were allocated at random (yes/no to manipulative therapy (manipulation and mobilization. Patient perceived recovery, severity of main complaint, shoulder pain, disability and general health were outcome measures. Data about direct and indirect costs were collected by means of a cost diary. Results Manipulative therapy as add-on to UMC accelerated recovery on all outcome measures included. At 26 weeks after randomization, both groups reported similar recovery rates (41% vs. 38%, but the difference between groups in improvement of severity of the main complaint, shoulder pain and disability sustained. Compared to the UMC group the total costs were higher in the manipulative group (€1167 vs. €555. This is explained mainly by the costs of the manipulative therapy itself and the higher costs due sick leave from work. The cost effectiveness ratio showed that additional manipulative treatment is more costly but also more effective than UMC alone. The cost-effectiveness acceptability curve shows that a 50%-probability of recovery with AMT within 6 months after initiation of treatment is achieved at €2876. Conclusion Manipulative therapy in addition to UMC accelerates recovery and is more effective than UMC alone on the long term, but is associated with higher costs. International Standard

  18. New methods for optical distance indicator and gantry angle quality control tests in medical linear accelerators: image processing by using a 3D phantom

    Energy Technology Data Exchange (ETDEWEB)

    Shandiz, Mahdi Heravian; Khalilzadeh, Mohammadmahdi; Anvari, Kazem [Mashhad Branch, Islamic Azad University, Mashhad (Iran, Islamic Republic of); Layen, Ghorban Safaeian [Mashhad University of Medical Science, Mashhad (Iran, Islamic Republic of)

    2015-03-15

    In order to keep the acceptable level of the radiation oncology linear accelerators, it is necessary to apply a reliable quality assurance (QA) program. The QA protocols, published by authoritative organizations, such as the American Association of Physicists in Medicine (AAPM), determine the quality control (QC) tests which should be performed on the medical linear accelerators and the threshold levels for each test. The purpose of this study is to increase the accuracy and precision of the selected QC tests in order to increase the quality of treatment and also increase the speed of the tests to convince the crowded centers to start a reliable QA program. A new method has been developed for two of the QC tests; optical distance indicator (ODI) QC test as a daily test and gantry angle QC test as a monthly test. This method uses an image processing approach utilizing the snapshots taken by the CCD camera to measure the source to surface distance (SSD) and gantry angle. The new method of ODI QC test has an accuracy of 99.95% with a standard deviation of 0.061 cm and the new method for gantry angle QC has a precision of 0.43 degrees. The automated proposed method which is used for both ODI and gantry angle QC tests, contains highly accurate and precise results which are objective and the human-caused errors have no effect on the results. The results show that they are in the acceptable range for both of the QC tests, according to AAPM task group 142.

  19. New methods for optical distance indicator and gantry angle quality control tests in medical linear accelerators: image processing by using a 3D phantom

    International Nuclear Information System (INIS)

    Shandiz, Mahdi Heravian; Khalilzadeh, Mohammadmahdi; Anvari, Kazem; Layen, Ghorban Safaeian

    2015-01-01

    In order to keep the acceptable level of the radiation oncology linear accelerators, it is necessary to apply a reliable quality assurance (QA) program. The QA protocols, published by authoritative organizations, such as the American Association of Physicists in Medicine (AAPM), determine the quality control (QC) tests which should be performed on the medical linear accelerators and the threshold levels for each test. The purpose of this study is to increase the accuracy and precision of the selected QC tests in order to increase the quality of treatment and also increase the speed of the tests to convince the crowded centers to start a reliable QA program. A new method has been developed for two of the QC tests; optical distance indicator (ODI) QC test as a daily test and gantry angle QC test as a monthly test. This method uses an image processing approach utilizing the snapshots taken by the CCD camera to measure the source to surface distance (SSD) and gantry angle. The new method of ODI QC test has an accuracy of 99.95% with a standard deviation of 0.061 cm and the new method for gantry angle QC has a precision of 0.43 degrees. The automated proposed method which is used for both ODI and gantry angle QC tests, contains highly accurate and precise results which are objective and the human-caused errors have no effect on the results. The results show that they are in the acceptable range for both of the QC tests, according to AAPM task group 142.

  20. Modern accelerators in ancient Rome

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    For the first time, the achievements and hopes of the broad European accelerator community were brought together in a European Particle Accelerator Conference, held in Rome in June. Ranging from the vast machines at CERN to the small medical accelerators operating in thousands of hospitals, the programme underlined how modern civilization has benefited from the ability to handle charged particle beams

  1. Modern accelerators in ancient Rome

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1988-09-15

    For the first time, the achievements and hopes of the broad European accelerator community were brought together in a European Particle Accelerator Conference, held in Rome in June. Ranging from the vast machines at CERN to the small medical accelerators operating in thousands of hospitals, the programme underlined how modern civilization has benefited from the ability to handle charged particle beams.

  2. Accelerator reliability workshop

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, L; Duru, Ph; Koch, J M; Revol, J L; Van Vaerenbergh, P; Volpe, A M; Clugnet, K; Dely, A; Goodhew, D

    2002-07-01

    About 80 experts attended this workshop, which brought together all accelerator communities: accelerator driven systems, X-ray sources, medical and industrial accelerators, spallation sources projects (American and European), nuclear physics, etc. With newly proposed accelerator applications such as nuclear waste transmutation, replacement of nuclear power plants and others. Reliability has now become a number one priority for accelerator designers. Every part of an accelerator facility from cryogenic systems to data storage via RF systems are concerned by reliability. This aspect is now taken into account in the design/budget phase, especially for projects whose goal is to reach no more than 10 interruptions per year. This document gathers the slides but not the proceedings of the workshop.

  3. Accelerator reliability workshop

    International Nuclear Information System (INIS)

    Hardy, L.; Duru, Ph.; Koch, J.M.; Revol, J.L.; Van Vaerenbergh, P.; Volpe, A.M.; Clugnet, K.; Dely, A.; Goodhew, D.

    2002-01-01

    About 80 experts attended this workshop, which brought together all accelerator communities: accelerator driven systems, X-ray sources, medical and industrial accelerators, spallation sources projects (American and European), nuclear physics, etc. With newly proposed accelerator applications such as nuclear waste transmutation, replacement of nuclear power plants and others. Reliability has now become a number one priority for accelerator designers. Every part of an accelerator facility from cryogenic systems to data storage via RF systems are concerned by reliability. This aspect is now taken into account in the design/budget phase, especially for projects whose goal is to reach no more than 10 interruptions per year. This document gathers the slides but not the proceedings of the workshop

  4. Hospital-based proton linear accelerator for particle therapy and radioisotope production

    Science.gov (United States)

    Lennox, Arlene J.

    1991-05-01

    Taking advantage of recent advances in linear accelerator technology, it is possible for a hospital to use a 70 MeV proton linac for fast neutron therapy, boron neutron capture therapy, proton therapy for ocular melanomas, and production of radiopharmaceuticals. The linac can also inject protons into a synchrotron for proton therapy of deep-seated tumors. With 180 μA average current, a single linac can support all these applications. This paper presents a conceptual design for a medical proton linac, switchyard, treatment rooms, and isotope production rooms. Special requirements for each application are outlined and a layout for sharing beam among the applications is suggested.

  5. Room temperature superconductors

    International Nuclear Information System (INIS)

    Sleight, A.W.

    1995-01-01

    If the Holy Grail of room temperature superconductivity could be achieved, the impact on could be enormous. However, a useful room temperature superconductor for most applications must possess a T c somewhat above room temperature and must be capable of sustaining superconductivity in the presence of magnetic fields while carrying a significant current load. The authors will return to the subject of just what characteristics one might seek for a compound to be a room temperature superconductor. 30 refs., 3 figs., 1 tab

  6. Accelerator Service

    International Nuclear Information System (INIS)

    Champelovier, Y.; Ferrari, M.; Gardon, A.; Hadinger, G.; Martin, J.; Plantier, A.

    1998-01-01

    Since the cessation of the operation of hydrogen cluster accelerator in July 1996, four electrostatic accelerators were in operation and used by the peri-nuclear teams working in multidisciplinary collaborations. These are the 4 MV Van de Graaff accelerator, 2,5 MV Van de Graaff accelerator, 400 kV ion implanter as well as the 120 kV isotope separator

  7. Determination of the neutron spectra in the treatment room of a linear accelerator for radiotherapy; Determinacion de los espectros de neutrones en la sala de tratamiento de un acelerador lineal para radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R. [Universidad Autonoma de Zacatecas, Cuerpo Academico de Radiobiologia, A.P. 336, 98000 Zacatecas (Mexico); Barquero, R. [Hospital Universitario Rio Hortega, Valladolid (Spain); Mendez, R.; Iniguez, M.P. [Depto. de Fisica Teorica, Atomica, Molecular y Nuclear, Universidad de Valladolid, 47011 Valladolid (Spain)

    2003-07-01

    By means of a series of measures and Monte Carlo calculations the dosimetric characteristics of the photoneutrons have been determined that take place in volume to a linear accelerator of radiotherapy of 18 MV, LINAC, mark Siemens Mevatron model. The measures were carried out with thermoluminescent dosemeters TLD 600 and TLD 700 that were naked exposed and confined with cover of Cd and Sn, inside a sphere of paraffin and inside spheres Bonner. (Author)

  8. [Projects to accelerate the practical use of innovative medical devices to collaborate with TWIns, Center for Advanced Biomedical Sciences, Waseda University and School of Engineering, The University of Tokyo].

    Science.gov (United States)

    Niimi, Shingo; Umezu, Mitsuo; Iseki, Hiroshi; Harada, Hiroshi Kasanuki Noboru; Mitsuishi, Mamoru; Kitamori, Takehiko; Tei, Yuichi; Nakaoka, Ryusuke; Haishima, Yuji

    2014-01-01

    Division of Medical Devices has been conducting the projects to accelerate the practical use of innovative medical devices to collaborate with TWIns, Center for Advanced Biomedical Sciences, Waseda University and School of Engineering, The University of Tokyo. The TWIns has been studying to aim at establishment of preclinical evaluation methods by "Engineering Based Medicine", and established Regulatory Science Institute for Medical Devices. School of Engineering, The University of Tokyo has been studying to aim at establishment of assessment methodology for innovative minimally invasive therapeutic devices, materials, and nanobio diagnostic devices. This report reviews the exchanges of personnel, the implement systems and the research progress of these projects.

  9. Overview of accelerators in medicine

    International Nuclear Information System (INIS)

    Lennox, A.J.

    1993-06-01

    Accelerators used for medicine include synchrotrons, cyclotrons, betatrons, microtrons, and electron, proton, and light ion linacs. Some accelerators which were formerly found only at physics laboratories are now being considered for use in hospital-based treatment and diagnostic facilities. This paper presents typical operating parameters for medical accelerators and gives specific examples of clinical applications for each type of accelerator, with emphasis on recent developments in the field

  10. Workshop on Accelerator Operation (WAO 2001)

    International Nuclear Information System (INIS)

    Bailey, R.

    2001-01-01

    The 3rd Workshop on Accelerator Operation (WAO 2001) followed earlier workshops in 1996 and 1998. Most topics relevant for the efficient and effective operation of accelerators were covered. These included the tools and utilities necessary in the control rooms; the organization of accelerator operation (process monitoring, shift work, stress); the monitoring of beam quality; safety issues and standards; and questions particularly relevant for superconducting accelerators, in particular cryogenics. (author)

  11. 8 October 2013 - Rolex Director- General G. Marini in the ATLAS Control Room with CERN Director-General R. Heuer and ATLAS Collaboration Senior Physicist C. Rembser; visiting the ATLAS experimental cavern at LHC Point 1. Were also present from the Directorate: S. Lettow, Director for Administration and General Infrastructure; from the ATLAS Collaboration: Technische Universitaet Dortmund (DE) J. Jentzsch and SLAC National Accelerator Laboratory (US) G. Piacquadio.

    CERN Multimedia

    Anna Pantelia

    2013-01-01

    8 October 2013 - Rolex Director- General G. Marini in the ATLAS Control Room with CERN Director-General R. Heuer and ATLAS Collaboration Senior Physicist C. Rembser; visiting the ATLAS experimental cavern at LHC Point 1. Were also present from the Directorate: S. Lettow, Director for Administration and General Infrastructure; from the ATLAS Collaboration: Technische Universitaet Dortmund (DE) J. Jentzsch and SLAC National Accelerator Laboratory (US) G. Piacquadio.

  12. Establishing the estimation model on radiation level at the ambience of 60Co radiotherapy treatment room based on NCRP REPORT No.151

    International Nuclear Information System (INIS)

    Yang Haiyou; Liu Liping; Liang Yueqin; Yu Shui

    2009-01-01

    Objective: To establish the estimation model to evaluate the radiation level at the ambience of 60 Co radiotherapy treatment room. Methods: The estimation model derives from NCRP REPORT No.151- S tructural Shielding Design and Evaluation for Megavoltage X-and Gamma-Ray Radiotherapy Facilities b y making appropriate adjustment, which presents the calculation methods on radiation level at the ambience of megavoltage medical electron linear accelerator treatment room. Results: The application scope of estimation model from NCRP REPORT No.151 is extended to γ-radiotherapy facilities, and it can be regarded as a new model for calculating the radiation level at the ambience of 60 Co radiotherapy treatment room. Conclusion: The estimation model has certain reference value to evaluate the radiation level at the ambience of 60 Co radiotherapy treatment room. (authors)

  13. APT accelerator technology

    International Nuclear Information System (INIS)

    Schneider, J. David

    1996-01-01

    The proposed accelerator production of tritium (APT) project requires an accelerator that provides a cw proton beam of 100 m A at 1300 MeV. Since the majority of the technical risk of a high-current cw (continuous-wave, 100% DF) accelerator resides in the low-energy section, Los Alamos is building a 20 MeV duplicate of the accelerator front end to confirm design codes, beam performance, and demonstrate operational reliability. We report on design details of this low-energy demonstration accelerator (LEDA) and discuss the integrated design of the full accelerator for the APT plant. LEDA's proton injector is under test and has produced more than 130 mA at 75 keV. Fabrication is proceeding on a 6.7- MeV, 8-meter-long RFQ, and detailed design is underway on coupled-cavity drift-tube linac (CCDTL) structures. In addition, detailed design and technology experiments are underway on medium-beta superconducting cavities to assess the feasibility of replacing the conventional (room-temperature copper) high-energy linac with a linac made of niobium superconducting RF cavities. (author)

  14. Advanced Accelerator Concepts

    Science.gov (United States)

    Siemann, Robert

    1998-04-01

    Current particle accelerators rely on conventional or superconducting radio frequency cavities to accelerate beams of protons or electrons for nuclear and particle research and for medical and materials science studies. New methods for achieving larger accelerating gradients have been proposed and are being studied. These include the use of high power lasers, laser driven plasmas, wake fields generated by intense low energy beams, and millimeter wavelength EM structures. The studies to date, and the prospects for practical applications of these new ideas will be discussed.

  15. Future accelerators (?)

    Energy Technology Data Exchange (ETDEWEB)

    John Womersley

    2003-08-21

    I describe the future accelerator facilities that are currently foreseen for electroweak scale physics, neutrino physics, and nuclear structure. I will explore the physics justification for these machines, and suggest how the case for future accelerators can be made.

  16. CSN's New Emergency Room

    International Nuclear Information System (INIS)

    Sendin, P.

    2005-01-01

    During the month of July 2005 the physical renovation works and technological updating of the basic infrastructures of the CSN Emergency Room (SALEM) were finished, allowing the Room to now have greater functionality and a broader technical capacity. Nevertheless, the technological improvement process of SALEM will reach its full potential within the next few years, once the installation currently underway of the new information integration and monitoring systems and the decision making support systems have been completed. This article describes the improvements introduced to the Room and the objectives pursued in this renovation project to convert the SALEM into a new generation room in accordance with its current technological context. (Author) 4 refs

  17. Computer vision based room interior design

    Science.gov (United States)

    Ahmad, Nasir; Hussain, Saddam; Ahmad, Kashif; Conci, Nicola

    2015-12-01

    This paper introduces a new application of computer vision. To the best of the author's knowledge, it is the first attempt to incorporate computer vision techniques into room interior designing. The computer vision based interior designing is achieved in two steps: object identification and color assignment. The image segmentation approach is used for the identification of the objects in the room and different color schemes are used for color assignment to these objects. The proposed approach is applied to simple as well as complex images from online sources. The proposed approach not only accelerated the process of interior designing but also made it very efficient by giving multiple alternatives.

  18. Medical radiation safety in the angiography room

    International Nuclear Information System (INIS)

    Kudou, Tamaki

    2011-01-01

    Author's efforts for angiographic procedure and technique aiming to reduce patient's exposure are described on a case with radiation skin hazard and on considerations of regulations and investigations. The case is a male patient (45 years old at the first intracardiac catheter examination, stature 164 cm, body wt. 116 kg), who, due to the diagnosis of angina pectoris and cardiac infarction, has the 5-year history of 5 coronary angiography (CAG), 6 percutaneous coronary intervention (PCI) and 1 off-pump coronary arterial bypass grafting (CABG). Because of serious skin injury and pain development after later PCI (172.2 min) (Oct. 2006) and their exacerbation after the latest PCI (27.1 min) (Apr. 2007), skin transplantation is conducted (Nov.). The exposure dose at the later PCI above is estimated to be around 12 Gy. Based on the case, consideration is made on regulatory recommendations by FDA, IAEA, ICRP, and investigational results of fluoroscopic mode vs dose by members of Japanese Circulatory Technology. With those references where the fluoroscopy at 20 mGy/min is assumed, the dose 12 Gy estimated above is thought to be resulted from the fluoroscopic dose >50 mGy/min within about 4 hr. To reduce the exposure, the author gives 11 items to be noted in interventional radiology: short fluoroscopic time, low rate pulse, minimal acquisition, use of additional filter, dose optimization, long distance between focus and skin, short distance between image intensifier (I.I.) and/or flat panel detector (FPD), minimal field, to avoid the excess inch-up, continuous maintenance of equipment, and record/preservation of the dose indicated by the machine. (T.T.)

  19. Medical Applications

    OpenAIRE

    Biscari, C.; Falbo, L.

    2016-01-01

    The use of accelerators for medical applications has evolved from initial experimentation to turn-key devices commonly operating in hospitals. New applications are continuously being developed around the world, and the hadrontherapy facilities of the newest generation are placed at the frontier between industrial production and advanced R&D. An introduction to the different medical application accelerators is followed by a description of the hadrontherapy facilities, with special emphasis on ...

  20. Virtual Seminar Room

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Fosgerau, Anders; Hansen, Peter Søren Kirk

    1999-01-01

    The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented.......The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented....

  1. Operating room manager game

    NARCIS (Netherlands)

    Hans, Elias W.; Nieberg, T.

    2007-01-01

    The operating room (OR) department of a hospital forms the heart of the organization, where the single largest cost is incurred. This document presents and reports on the “Operating Room Manager Game,” developed to give insight into managing a large hospital's OR department at various levels of

  2. Neutron activation processes in the medical linear accelerator Elekta Precise; Procesos de activacion neutronica en el acelerador lineal medico Elekta Precise

    Energy Technology Data Exchange (ETDEWEB)

    Juste, B.; Miro, R.; Verdu, G.; Diez, S.; Campayo, J. M.

    2014-07-01

    In radiotherapy beams of high energy photons produced lower doses in the skin and a lower dose dispersed into surrounding healthy tissue. However, when operating above 10 MV, Linacs have some drawbacks such as the generation of photo-neutrons and activation of some components of the accelerator. The launch and capture of neutrons produce radioactive nuclei that can radiate even when the accelerator is not working. These reactions occur mainly in the heavier materials of the head accelerator. This work has studied the activation generated isotopes resulting, concluding that these derived doses are not negligible. (Author)

  3. Recent progress in particle accelerators

    International Nuclear Information System (INIS)

    Cole, F.T.; Mills, F.E.

    1988-01-01

    Many accelerators have also been built for medical radiography and therapy. Electron accelerators for this application are available commercially, using the electrons directly or bremsstrahlung photons. Neutrons produced by accelerator beams have also been used for therapy with considerable success, and several proton accelerators built for physics research have been adapted for direct therapy with protons. The first proton accelerator specifically for therapy is now being built. Separate from what might be called conventional accelerator technology, an entirely new field utilizing very highly pulsed power has been developed, and beams of short pulses of thousands or millions of amperes peak current in the MeV energy range are now available. These beams have important applications in high-energy particle acceleration, controlled fusion, industrial treatment of materials, and possibly in food preservation. All of these accelerators make use of external fields of acceleration. There is also vigorous research into new methods of acceleration, in many schemes making use of the intense accelerating fields, generated by laser beams or by plasma states of matter. This research has not as yet made traditional kinds of accelerators outmoded, but many workers hope that early in the next century there will be practical new acceleration methods making use of these very high fields. These developments are discussed in detail

  4. The miniature accelerator

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    The image that most people have of CERN is of its enormous accelerators and their capacity to accelerate particles to extremely high energies. But thanks to some cutting-edge studies on beam dynamics and radiofrequency technology, along with innovative construction techniques, teams at CERN have now created the first module of a brand-new accelerator, which will be just 2 metres long. The potential uses of this miniature accelerator will include deployment in hospitals for the production of medical isotopes and the treatment of cancer. It’s a real David-and-Goliath story.   Serge Mathot, in charge of the construction of the "mini-RFQ", pictured with the first of the four modules that will make up the miniature accelerator. The miniature accelerator consists of a radiofrequency quadrupole (RFQ), a component found at the start of all proton accelerator chains around the world, from the smallest to the largest. The LHC is designed to produce very high-intensity beams ...

  5. Electrostatic accelerators

    OpenAIRE

    Hinterberger, F

    2006-01-01

    The principle of electrostatic accelerators is presented. We consider Cockcroft– Walton, Van de Graaff and Tandem Van de Graaff accelerators. We resume high voltage generators such as cascade generators, Van de Graaff band generators, Pelletron generators, Laddertron generators and Dynamitron generators. The speci c features of accelerating tubes, ion optics and methods of voltage stabilization are described. We discuss the characteristic beam properties and the variety of possible beams. We ...

  6. Engineering Process Monitoring for Control Room Operation

    CERN Document Server

    Bätz, M

    2001-01-01

    A major challenge in process operation is to reduce costs and increase system efficiency whereas the complexity of automated process engineering, control and monitoring systems increases continuously. To cope with this challenge the design, implementation and operation of process monitoring systems for control room operation have to be treated as an ensemble. This is only possible if the engineering of the monitoring information is focused on the production objective and is lead in close collaboration of control room teams, exploitation personnel and process specialists. In this paper some principles for the engineering of monitoring information for control room operation are developed at the example of the exploitation of a particle accelerator at the European Laboratory for Nuclear Research (CERN).

  7. Electrostatic accelerators

    CERN Document Server

    Hinterberger, F

    2006-01-01

    The principle of electrostatic accelerators is presented. We consider Cockcroft– Walton, Van de Graaff and Tandem Van de Graaff accelerators. We resume high voltage generators such as cascade generators, Van de Graaff band generators, Pelletron generators, Laddertron generators and Dynamitron generators. The speci c features of accelerating tubes, ion optics and methods of voltage stabilization are described. We discuss the characteristic beam properties and the variety of possible beams. We sketch possible applications and the progress in the development of electrostatic accelerators.

  8. Accelerator development

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Because the use of accelerated heavy ions would provide many opportunities for new and important studies in nuclear physics and nuclear chemistry, as well as other disciplines, both the Chemistry and Physics Divisions are supporting the development of a heavy-ion accelerator. The design of greatest current interest includes a tandem accelerator with a terminal voltage of approximately 25 MV injecting into a linear accelerator with rf superconducting resonators. This combined accelerator facility would be capable of accelerating ions of masses ranging over the entire periodic table to an energy corresponding to approximately 10 MeV/nucleon. This approach, as compared to other concepts, has the advantages of lower construction costs, lower operating power, 100 percent duty factor, and high beam quality (good energy resolution, good timing resolution, small beam size, and small beam divergence). The included sections describe the concept of the proposed heavy-ion accelerator, and the development program aiming at: (1) investigation of the individual questions concerning the superconducting accelerating resonators; (2) construction and testing of prototype accelerator systems; and (3) search for economical solutions to engineering problems. (U.S.)

  9. The Virtual Dressing Room

    DEFF Research Database (Denmark)

    Holte, Michael Boelstoft; Gao, Yi; Petersson, Eva

    2015-01-01

    This paper presents the design and evaluation of a usability and user experience test of a virtual dressing room. First, we motivate and introduce our recent developed prototype of a virtual dressing room. Next, we present the research and test design grounded in related usability and user...... experience studies. We give a description of the experimental setup and the execution of the designed usability and user experience test. To this end, we report interesting results and discuss the results with respect to user-centered design and development of a virtual dressing room....

  10. Films and dark room

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    After we know where the radiographic come from, then we must know about the film and also dark room. So, this chapter 5 discusses the two main components for radiography work that is film and dark room, places to process the film. Film are structured with three structured that are basic structured, emulsion and protection structured. So, this film can be classified either with their speed, screen and standard that used. The process to wash the film must be done in dark room otherwise the radiographer cannot get what are they inspected. The processing of film will be discussed briefly in next chapter.

  11. Room Acoustical Fields

    CERN Document Server

    Mechel, Fridolin

    2013-01-01

    This book presents the theory of room acoustical fields and revises the Mirror Source Methods for practical computational use, emphasizing the wave character of acoustical fields.  The presented higher methods include the concepts of “Mirror Point Sources” and “Corner sources which allow for an excellent approximation of complex room geometries and even equipped rooms. In contrast to classical description, this book extends the theory of sound fields describing them by their complex sound pressure and the particle velocity. This approach enables accurate descriptions of interference and absorption phenomena.

  12. Developing a clinical proton accelerator facility: Consortium-assisted technology transfer

    International Nuclear Information System (INIS)

    Slater, J.M.; Miller, D.W.; Slater, J.W.

    1991-01-01

    A hospital-based proton accelerator facility has emerged from the efforts of a consortium of physicists, engineers and physicians from several high-energy physics laboratories, industries and universities, working together to develop the requirements and conceptual design for a clinical program. A variable-energy medical synchrotron for accelerating protons to a prescribed energy, intensity and beam quality, has been placed in a hospital setting at Loma Linda University Medical Center for treating patients with localized cancer. Treatments began in October 1990. Scientists from Fermi National Accelerator Laboratory; Harvard Cyclotron Laboratory; Lawrence Berkeley Laboratories; the Paul Scherrer Institute; Uppsala, Sweden; Argonne, Brookhaven and Los Alamos National Laboratories; and Loma Linda University, all cooperated to produce the conceptual design. Loma Linda University contracted with Fermi National Accelerator Laboratory to design and build a 250 MeV synchrotron and beam transport system, the latter to guide protons into four treatment rooms. Lawrence Berkeley Laboratories consulted with Loma Linda University on the design of the beam delivery system (nozzle). A gantry concept devised by scientists at Harvard Cyclotron Laboratory, was adapted and fabricated by Science Applications International Corporation. The control and safety systems were designed and developed by Loma Linda University Radiation Research Laboratory. Presently, the synchrotron, beam transport system and treatment room hardware have been installed and tested and are operating satisfactorily

  13. Anatomía Humana: estudio de las reacciones de los estudiantes de primero de medicina ante la sala de disección Human Anatomy: reactions of first year medical students to the dissection room

    Directory of Open Access Journals (Sweden)

    Maribel Miguel Pérez

    2007-06-01

    Full Text Available Introducción: El objetivo de este estudio es reflejar las reacciones físicas y emocionales de los estudiantes de primer curso de Medicina de la Universidad de Barcelona (Campus de Bellvitge ante la sala de disección. Material y métodos: Los estudiantes responden a tres cuestionarios que valoran la intensidad del miedo, las reacciones físicas y psicológicas frente la sala de disección y los métodos de afrontamiento, en dos momentos del curso: al inicio y al final del curso académico. Resultados: Las reacciones más frecuentes fueron la sensación de disgusto, la pérdida del apetito, las imágenes visuales recurrentes de los cadáveres, el insomnio y las pesadillas. Respecto a los métodos de afrontamiento más usados por los estudiantes para contrarrestar las reacciones adversas correspondieron en juntarse y hacer broma con los amigos, estudiar anatomía y pedir consejo a compañeros y profesores. Conclusiones: La sala de disección representa, para los estudiantes del primer curso de medicina, el primer encuentro relacionado con la muerte y ésta, a la vez, implica el desarrollo de mecanismos de adaptación en su futuro profesional. Los profesores de anatomía no solo tienen una mera función docente como transmisores de contenidos, sino que también deberían dar apoyo a la adaptación progresiva de los alumnos a la sala de disección.Introduction: The aim of this study is to record the physical and emotional reactions of the first-year medical students at the University of Barcelona (Campus de Bellvitge to the dissection room. Material and methods: Three questionnaires focusing on degree of fear and psychological and physical reactions were prepared and administered to students before the first dissection session, after the first dissection, and at the end of the course. Results: The most frequent reactions were sensation of disgust, loss of appetite, recurring visual images of cadavers, insomnia and nightmares. To cope with these

  14. Our Urban Living Room

    DEFF Research Database (Denmark)

    Hjortshøj, Rasmus

    2016-01-01

    Our Urban Living Room is an exhibition and a book, created by Cobe. The theme is based on Cobe’s ten years of practice, grounded in social livability and urban democracy, and our aim to create buildings and spaces that invite Copenhageners to use and define them; as an extended living room, where...... the boundaries between private and public space become fluid. Based on specific Cobe projects, Our Urban Living Room tells stories about the architectural development of Copenhagen, while exploring the progression of the Danish Capital - from an industrial city into an urban living room, known as one...... of the world’s most livable places. Photography by Rasmus Hjortshøj....

  15. Photographic art in exam rooms may reduce white coat hypertension.

    Science.gov (United States)

    Harper, Michael B; Kanayama-Trivedi, Stacy; Caldito, Gloria; Montgomery, David; Mayeaux, E J; DelRosso, Lourdes M

    2015-12-01

    Blood pressure (BP) elevation in medical office settings in patients who are normotensive in nonmedical settings is an effect known as 'white coat hypertension'. This phenomenon is thought to be due to situational anxiety caused by the experience of visiting a doctor and the anxiety-inducing nature of the medical office. Our study was designed to determine if carefully selected photographic art could counter the anxiety that causes white coat hypertension and lead to lower BP recordings in some patients. 117 adults, non-pregnant patients from the Louisiana State University Health Sciences Center Family Medicine Resident Clinic participated in this study. After the triage nurse measured the BP, the patients were randomly placed in either an exam room with standard medical posters (control room) or in an exam room with photographic art (photo room). The BP was measured in the exam room. After the medical visit, the patients switched rooms and the BP was measured a third time. The patients were asked to fill out a questionnaire to identify room preference. On average, the BP obtained in the control rooms was higher than that obtained in the photo rooms. There was a statistically significant difference between the mean arterial pressure, systolic BP and diastolic BP between the control room and the photo room. Landscape photographic art may have the beneficial effect of reducing BP in medical office examination rooms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. RECIRCULATING ACCELERATION

    International Nuclear Information System (INIS)

    BERG, J.S.; GARREN, A.A.; JOHNSTONE, C.

    2000-01-01

    This paper compares various types of recirculating accelerators, outlining the advantages and disadvantages of various approaches. The accelerators are characterized according to the types of arcs they use: whether there is a single arc for the entire recirculator or there are multiple arcs, and whether the arc(s) are isochronous or non-isochronous

  17. LIBO accelerates

    CERN Multimedia

    2002-01-01

    The prototype module of LIBO, a linear accelerator project designed for cancer therapy, has passed its first proton-beam acceleration test. In parallel a new version - LIBO-30 - is being developed, which promises to open up even more interesting avenues.

  18. Electron accelerators for environmental protection

    International Nuclear Information System (INIS)

    Zimek, Z.

    1998-01-01

    The primary objective of this publication is to provide information suitable for electron accelerators implementation in facilities applying radiation technology for environmental protection. It should be noticed that radiation processing has been successfully used in the fields of crosslinking polymer curing and medical products sterilization for more than 40 years. Practical application of radiation technology today extends on SO 2 and NO x removal from the flue gas (one of major power intensive radiation processing), destruction and removal of organic chemicals from water, decreasing bacteria content in the irradiated sludge and waste water. On the other hand the increased awareness of environmental pollution hazards and more stringent waste regulations in many countries may open stronger support for environmentally oriented technologies. This publication provides an evaluation of electron accelerators capabilities in respect of environmental applications where technological and economical criteria are now well defined. In order to determine the potential of electron accelerators, the literature data were examined as well visits and meetings with various accelerator manufacturers were performed by the author. Experience of the author in accelerator facilities construction and exploitation including those which were used for environmental protection are significant part of this publication. The principle of accelerator action was described in Chapter 1. Early development, accelerator classification and fields of accelerators application were included to this chapter as well. Details of accelerator construction was described in Chapter 2 to illustrate physical capability of accelerators to perform the function of ionizing radiation source. Electron beam extraction devices, under beam equipment, electron beam parameters and measuring methods were characterized in this chapter as well. Present studies of accelerator technology was described in Chapter 3, where

  19. Accelerating Inspire

    CERN Document Server

    AUTHOR|(CDS)2266999

    2017-01-01

    CERN has been involved in the dissemination of scientific results since its early days and has continuously updated the distribution channels. Currently, Inspire hosts catalogues of articles, authors, institutions, conferences, jobs, experiments, journals and more. Successful orientation among this amount of data requires comprehensive linking between the content. Inspire has lacked a system for linking experiments and articles together based on which accelerator they were conducted at. The purpose of this project has been to create such a system. Records for 156 accelerators were created and all 2913 experiments on Inspire were given corresponding MARC tags. Records of 18404 accelerator physics related bibliographic entries were also tagged with corresponding accelerator tags. Finally, as a part of the endeavour to broaden CERN's presence on Wikipedia, existing Wikipedia articles of accelerators were updated with short descriptions and links to Inspire. In total, 86 Wikipedia articles were updated. This repo...

  20. The Doctrinal Basis for Medical Stability Operations

    Science.gov (United States)

    2010-01-01

    lead actor, preferably a HN agency, but sometimes the military must take the lead in medical stability operations when overwhelming violence prevents...34 Assessment Tasks Administration of hospital Communications Obstetrics , Pediatrics, Emergency room. Operating room Nursing procedures Medical supply

  1. Medical Cyclotrons

    Science.gov (United States)

    Friesel, D. L.; Antaya, T. A.

    Particle accelerators were initially developed to address specific scientific research goals, yet they were used for practical applications, particularly medical applications, within a few years of their invention. The cyclotron's potential for producing beams for cancer therapy and medical radioisotope production was realized with the early Lawrence cyclotrons and has continued with their more technically advanced successors — synchrocyclotrons, sector-focused cyclotrons and superconducting cyclotrons. While a variety of other accelerator technologies were developed to achieve today's high energy particles, this article will chronicle the development of one type of accelerator — the cyclotron, and its medical applications. These medical and industrial applications eventually led to the commercial manufacture of both small and large cyclotrons and facilities specifically designed for applications other than scientific research.

  2. FMIT accelerator

    International Nuclear Information System (INIS)

    Armstrong, D.D.

    1983-01-01

    A 35-MeV 100-mA cw linear accelerator is being designed by Los Alamos for use in the Fusion Materials Irradiation Test (FMIT) Facility. Essential to this program is the design, construction, and evaluation of performance of the accelerator's injector, low-energy beam transport, and radio-frequency quadrupole sections before they are shipped to the facility site. The installation and testing of some of these sections have begun as well as the testing of the rf, noninterceptive beam diagnostics, computer control, dc power, and vacuum systems. An overview of the accelerator systems and the performance to date is given

  3. Electron accelerator

    International Nuclear Information System (INIS)

    Abramyan.

    1981-01-01

    The USSR produces an electron accelerator family of a simple design powered straight from the mains. The specifications are given of accelerators ELITA-400, ELITA-3, ELT-2, TEUS-3 and RIUS-5 with maximum electron energies of 0.3 to 5 MeV, a mean power of 10 to 70 kW operating in both the pulsed and the continuous (TEUS-3) modes. Pulsed accelerators ELITA-400 and ELITA-3 and RIUS-5 in which TESLA resonance transformers are used are characterized by their compact size. (Ha)

  4. Test Room Stability Plan

    International Nuclear Information System (INIS)

    1993-01-01

    This plan documents the combination of designs, installations, programs, and activities that ensures that the underground excavations at the Waste Isolation Pilot Plant (WIPP), in which transuranic (TRU) waste may be emplaced during the Test Phase, will remain sufficiently stable and safe during that time. The current ground support systems installed at the WIPP are the result of over ten years of data collection from hundreds of geomechanical instruments and thousands of hours of direct observation of the changing conditions of the openings. In addition, some of the world's most respected experts on salt rock mechanics have provided input in the design process and concurrence on the suitability of the final design. The general mine rockbolt pattern and the ground support system for the test rooms are designed to specifically address the fracture and deformation geometries observed today at the WIPP. After an introductory chapter, this plan describes the general underground design, then proceeds to an account of general ground support performance, and finally focuses on the details of the special test room ground support systems. One such system already installed in Room 1, Panel 1, is described in comprehensive detail. Other test rooms in Panel 1, whether full-size or smaller, will be equipped with systems that ensure stability to the same or equivalent extent. They will benefit from the experience gained in the first test room, which in turn benefitted from the data and knowledge accumulated during previous stages (e.g., the Site and Preliminary Design Validation program) of the project

  5. Accelerator Based Neutron Beams for Neutron Capture Therapy

    International Nuclear Information System (INIS)

    Yanch, Jacquelyn C.

    2003-01-01

    The DOE-funded accelerator BNCT program at the Massachusetts Institute of Technology has resulted in the only operating accelerator-based epithermal neutron beam facility capable of generating significant dose rates in the world. With five separate beamlines and two different epithermal neutron beam assemblies installed, we are currently capable of treating patients with rheumatoid arthritis in less than 15 minutes (knee joints) or 4 minutes (finger joints) or irradiating patients with shallow brain tumors to a healthy tissue dose of 12.6 Gy in 3.6 hours. The accelerator, designed by Newton scientific Incorporated, is located in dedicated laboratory space that MIT renovated specifically for this project. The Laboratory for Accelerator Beam Applications consists of an accelerator room, a control room, a shielded radiation vault, and additional laboratory space nearby. In addition to the design, construction and characterization of the tandem electrostatic accelerator, this program also resulted in other significant accomplishments. Assemblies for generating epithermal neutron beams were designed, constructed and experimentally evaluated using mixed-field dosimetry techniques. Strategies for target construction and target cooling were implemented and tested. We demonstrated that the method of submerged jet impingement using water as the coolant is capable of handling power densities of up to 6 x 10(sup 7) W/m(sup 2) with heat transfer coefficients of 10(sup 6)W/m(sup 2)-K. Experiments with the liquid metal gallium demonstrated its superiority compared with water with little effect on the neutronic properties of the epithermal beam. Monoenergetic proton beams generated using the accelerator were used to evaluate proton RBE as a function of LET and demonstrated a maximum RBE at approximately 30-40 keV/um, a finding consistent with results published by other researchers. We also developed an experimental approach to biological intercomparison of epithermal beams and

  6. Shielding Calculations for Industrial 5/7.5MeV Electron Accelerators Using the MCNP Monte Carlo Code

    International Nuclear Information System (INIS)

    Peri, E.; Orion, I.

    2014-01-01

    High energy X-rays from accelerators are used to irradiate food ingredients to prevent growth and development of unwanted biological organisms in food, in order to extend the shelf life of products. High energy photons can cause food activation due to (D 3 ,n) reactions. Until 2004, to eliminate the possibility of food activation, the electron energy was limited to 5 MeV X-rays for food irradiation. In 2004, the FDA approved the usage of up to 7.5 MeV, but only with tantalum and gold targets (1). Higher X-ray energy results an increased flux of X-rays in the forward direction, increased penetration, and higher photon dose rate due to better electron-to-photon conversion. These improvements could decrease the irradiation time and allow irradiation of larger packages, thereby providing higher production rates with lower treatment cost. Medical accelerators usually work with 6-18 MV electron energy with tungsten target to convert the electron beam to X-rays. In order to protect the patients, the accelerator head is protected with a heavy lead shielding; therefore, the bremsstrahlung is emitted only in the forward direction. There are many publications and standards that guide how to design optimal shielding for medical accelerator rooms. The shielding data for medical accelerators is not applicable for industrial accelerators, since the data is for different conversion targets, different X-Ray energies, and only for the forward direction. Collimators are not always in use in industrial accelerators, and therefore bremsstrahlung photons can be emitted in all directions. The bremsstrahlung spectrum and dose rate change as a function of the emission angle. The dose rate decreases from maximum in the forward direction (0°) to minimum at 180° by 1-2 orders of magnitude. In order to design and calculate optimal shielding for food accelerator rooms, there is a need to have the bremsstrahlung spectrum data, dose rates and concrete attenuation data in all emission directions

  7. Horizontal Accelerator

    Data.gov (United States)

    Federal Laboratory Consortium — The Horizontal Accelerator (HA) Facility is a versatile research tool available for use on projects requiring simulation of the crash environment. The HA Facility is...

  8. Acceleration theorems

    International Nuclear Information System (INIS)

    Palmer, R.

    1994-06-01

    Electromagnetic fields can be separated into near and far components. Near fields are extensions of static fields. They do not radiate, and they fall off more rapidly from a source than far fields. Near fields can accelerate particles, but the ratio of acceleration to source fields at a distance R, is always less than R/λ or 1, whichever is smaller. Far fields can be represented as sums of plane parallel, transversely polarized waves that travel at the velocity of light. A single such wave in a vacuum cannot give continuous acceleration, and it is shown that no sums of such waves can give net first order acceleration. This theorem is proven in three different ways; each method showing a different aspect of the situation

  9. Control room design

    International Nuclear Information System (INIS)

    Zinke, H.

    1980-01-01

    To control a 1300 megawatt nuclear power plant, about 15000 plant parameters must be collected together to control and operate the plant. The control room design therefore is of particular importance. The main design criteria are: Required functions of the power plant process - Level of Automation - Ergonomics - Available Technology. Extensive analysis has resulted in a control room design method. This ensures that an objective solution will be reached. Resulting from this methodical approach are: 1. Scope, position and appearance of the instrumentation. 2. Scope, position and appearance of the operator controls. Process analysis dictates what instrumentation and operator controls are needed. The priority and importance of the control and instrumentation (this we define as the utilisation areas), dictates the rough layout of the control room. (orig./RW)

  10. Room for caring

    DEFF Research Database (Denmark)

    Timmermann, Connie; Uhrenfeldt, Lisbeth; Birkelund, Regner

    2015-01-01

    Aim This study explores how seriously ill hospitalized patients' experience and assign meaning to their patient room. Background Modern hospitals and the rational underlying care and treatment of today have their emphasis on diagnosis, cure and treatment. Consequently, aesthetics in the patient...... rooms such as a view of nature or natural light entering the room are often neglected in caring for these patients. Method A phenomenological-hermeneutic study design was applied and data was collected through multiple qualitative interviews combined with observations at a teaching hospital in Denmark......-being, relief and hope for the patients during serious illness. Therefore, these sensory impressions should be thought of as holding palliative potential and should be included as a part of caring for the seriously ill patients....

  11. Clinic exam room design: present and future.

    Science.gov (United States)

    Freihoefer, Kara; Nyberg, Gary; Vickery, Christine

    2013-01-01

    This article aims to deconstruct various design qualities and strategies of clinic exam rooms, and discuss how they influence users' interaction and behavior in the space. Relevant literature supports the advantages and disadvantages of different design strategies. Annotated exam room prototypes illustrate the design qualities and strategies discussed. Advancements in technology and medicine, along with new legislative policies, are influencing the way care providers deliver care and ultimately clinic exam room designs. The patient-centered medical home model has encouraged primary care providers to make patients more active leaders of their health plan which will influence the overall functionality and configuration of clinic exam rooms. Specific design qualities discussed include overall size, location of doors and privacy curtains, positioning of exam tables, influence of technology in the consultation area, types of seating, and placement of sink and hand sanitizing dispensers. In addition, future trends of exam room prototypes are presented. There is a general lack of published evidence to support design professionals' design solutions for outpatient exam rooms. Future research should investigate such topics as the location of exam tables and privacy curtains as they relate to patient privacy; typical size and location of consultation table as it relates to patient connection and communication; and placement of sinks and sanitization dispensers as they relate to frequency and patterns of usage. Literature review, outpatient, technology, visual privacy.

  12. A new main control room for the AGS complex

    International Nuclear Information System (INIS)

    Ingrassia, P.F.; Zaharatos, R.M.; Dyling, O.H.

    1991-01-01

    A new Main Control Room (MCR) has been built to control the accelerators of the AGS Complex. A new physical environment was produced to better control light, sound, temperature, and traffic. New control consoles were built around the work-stations that make up the distributed control system. Equipment placement within consoles and console placement within the room reflect attention to the ''human factors'' needs of the operator. 1 ref., 2 figs

  13. A new Main Control Room for the AGS complex

    International Nuclear Information System (INIS)

    Ingrassia, P.F.; Zaharatos, R.M.; Dyling, O.H.

    1991-01-01

    A new Main Control Room (MCR) has been built to control the accelerators of the AGS Complex. A new physical environment was produced to better control light, sound, temperature, and traffic. New control consoles were built around the work-stations that make up the distributed control system. Equipment placement within consoles and console placement within the room reflect attention to the 'human factors' needs of the operator

  14. LINEAR ACCELERATOR

    Science.gov (United States)

    Christofilos, N.C.; Polk, I.J.

    1959-02-17

    Improvements in linear particle accelerators are described. A drift tube system for a linear ion accelerator reduces gap capacity between adjacent drift tube ends. This is accomplished by reducing the ratio of the diameter of the drift tube to the diameter of the resonant cavity. Concentration of magnetic field intensity at the longitudinal midpoint of the external sunface of each drift tube is reduced by increasing the external drift tube diameter at the longitudinal center region.

  15. The Virtual Dressing Room

    DEFF Research Database (Denmark)

    Holte, Michael Boelstoft

    2013-01-01

    This paper presents a review of recent developments and future perspectives, addressing the problem of creating a virtual dressing room. First, we review the current state-of-the-art of exiting solutions and discuss their applicability and limitations. We categorize the exiting solutions into three...... kinds: (1) virtual real-time 2D image/video techniques, where the consumer gets to superimpose the clothes on their real-time video to visualize themselves wearing the clothes. (2) 2D and 3D mannequins, where a web-application uses the body measurements provided by the customer, to superimpose...... and their demands to a virtual dressing room....

  16. Birth room images

    DEFF Research Database (Denmark)

    Bowden, Calida; Sheehan, Athena; Foureur, Maralyn Jean

    2016-01-01

    Objective: this study examined images of birth rooms in developed countries to analyse the messages and visual discourse being communicated through images. Design: a small qualitative study using Kress and van Leeuwen's (2006) social semiotic theoretical framework for image analysis, a form...... and implications for practice: as images on the Internet inform and persuade society about stereotypical behaviours, the trends of our time and sociocultural norms, it is important to recognise images of the technological birth room on the Internet may be influential in dictating women's attitudes, choices...

  17. The changing sensory room

    DEFF Research Database (Denmark)

    2018-01-01

    In 2017 the kindergarten The Milky Way in the city Vejle in Denmark made a sensory room that has the special ability change whenever wanted by the children and social educators. Kjetil Sandvik (to the right) from Copenhagen University and Klaus Thestrup from Aarhus University reflects upon what...... they saw, took part in and talked with the social educators about. Jacob Knudsen from VIFIN filmed the two gentlemen and organised the project. it is a room composed around common experiments, many self-made objects, open narrative structures. and a combination of digital and analogue elements....

  18. Accelerators for therapy

    International Nuclear Information System (INIS)

    Pohlit, W.

    1994-01-01

    In the past decades circular and linear electron accelerators have been developed for clinical use in radiation therapy of tumors with the aim of achieving a high radiation dose in the tumor and as low as possible dose in the adjacent normal tissues. Today about one thousand accelerators are in medical use throughout the world and many hundred thousand patients are treated every day with accelerator-produced radiation. There exists, however, a large number of patients who cannot be treated satisfactorily in this way. New types of radiations such as neutrons, negative pions, protons and heavy ions were therefore tested recently. The clinical experience with these radiations and with new types of treatment procedures indicate that in future the use of a scanning beam of high energy protons might be optimal for the treatment of tumors. (orig.)

  19. Creating an adaptive healing room for neurology patients

    NARCIS (Netherlands)

    Daemen, E.M.L; Behere, S.; Cuppen, R.P.G.; Facey, J.; Flinsenberg, I.C.M.; Loenen, van E.J.; Rajae-Joordens, R.J.E.

    2013-01-01

    Informed by the experiences of patients and medical staff, Philips has designed a room for neurology patients that retains a clinical feel when treatment is being carried out, but can flex to create a moretailored, personal ambiende.

  20. Performance of linear accelerator Mevatron-74 at Sher-i-Kashmir Institute of Medical Sciences, Soura, Srinagar - a 15 years experience

    International Nuclear Information System (INIS)

    Bhat, M.A.; Abbas, S.M.; Kaul, S.K.; Khan, F.A.; Ashraf Teli, M.

    1998-01-01

    In 1984, a linear accelerator, Mevatron-74 was installed in the Dept. of Radiation Oncology. Discussed in this paper is our experience with this costly machine which has not been cost effective at all with regard to the purpose it was purchased for. This will lay a guideline for the developing centres of our country to make correct decision as regards the purchase of radiotherapy equipment keeping in view their performance

  1. The Use of Online Quizlet.com Resource Tools to Support Native English Speaking Students of Engineering and Medical Departments in Accelerated RFL Teaching and Learning

    OpenAIRE

    Kh.E. Ismailova; K. Gleason; E.A. Provotorova; P.G. Matukhin

    2016-01-01

    The paper presents a description of the methodology and some results of the application of tools of the language learning support portal Quizlet.com to improve the effectiveness of the accelerated development of the basic communicative skills in Russian as a foreign language (RFL) for the group of the English-speaking students who arrived to study in Russia engineering, medicine and other areas. The application of the development is the basics of Russian teaching and learning in the classroom...

  2. The Use of Online Quizlet.com Resource Tools to Support Native English Speaking Students of Engineering and Medical Departments in Accelerated RFL Teaching and Learning

    OpenAIRE

    Ismailova , Kh ,; Gleason , K ,; Provotorova , P ,; Matukhin , P ,

    2017-01-01

    International audience; The paper presents a description of the methodology and some results of the application of tools of the language learning support portal Quizlet.com to improve the effectiveness of the accelerated development of the basic communicative skills in Russian as a foreign language (RFL) for the group of the English-speaking students who arrived to study in Russia engineering, medicine and other areas. The application of the development is the basics of Russian teaching and l...

  3. PS Control Room

    CERN Multimedia

    CERN PhotoLab

    1963-01-01

    The good old PS Control Room, all manual. For each parameter, a knob or a button to control it; for each, a light or meter or oscilloscope to monitor it; carefully written pages serve as the data bank; phones and intercom for communication. D.Dekkers is at the microphone, M.Valvini sits in front.

  4. Room for iodo therapy

    International Nuclear Information System (INIS)

    Pinto, A.L.A.; Derivi, A.; Bacelar, A.; Ramos, F.R.; Dias, T.M.; Baptista, I.S.

    1996-01-01

    A description of rules to assemble, to install and to maintain a room for iodo therapy is presented. The necessities of the patients and procedures to meet the norms of radiologic protection established by the Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil) are highlighted

  5. Local control room

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Local control room in the ejection building : all electronics pertaining to proton distribution and concomitants such as beam gymnastics and diagnostics at high energies will eventually be gathered here. Shown is the first of two rows of fast ejection electronic racks. It includes only what is necessary for operation.

  6. DSS / Press Room

    Science.gov (United States)

    Defense Security Service, U.S. Department of Defense Site Map | A-Z Index | Facebook | Twitter Locations Press Room Organizational Structure Careers at DSS Doing Business with DSS Frequently Asked Classification System (NCCS) National Industrial Security System (NISS) ODAA Business Management System (OBMS

  7. Controlling the clean room atmosphere

    International Nuclear Information System (INIS)

    Meeks, R.F.

    1979-01-01

    Several types of clean rooms are commonly in use. They include the conventional clean room, the horizontal laminar flow clean room, the vertical laminar flow clean room and a fourth type that incorporates ideas from the previous types and is known as a clean air bench or hood. These clean rooms are briefly described. The origin of contamination and methods for controlling the contamination are discussed

  8. A Miracle That Accelerates Operating Room Functionality: Sugammadex

    OpenAIRE

    Dogan, Erdal; Akdemir, Mehmet Salim; Guzel, Abdulmenap; Yildirim, Mehmet Besir; Baysal Yildirim, Zeynep; Kuyumcu, Mahir; Gümüş, Abdurrahman; Akelma, Hakan

    2014-01-01

    Background. Sugammadex offers a good alternative to the conventional decurarisation process currently performed with cholinesterase inhibitors. Sugammadex, which was developed specifically for the aminosteroid-structured rocuronium and vecuronium neuromuscular blockers, is a modified cyclodextrin made up of 8 glucose monomers arranged in a cylindrical shape. Methods. In this study, the goal was to investigate the efficacy of sugammadex. Sugammadex was used when there was insufficient decurari...

  9. A Miracle That Accelerates Operating Room Functionality: Sugammadex

    Science.gov (United States)

    Dogan, Erdal; Akdemir, Mehmet Salim; Guzel, Abdulmenap; Yildirim, Mehmet Besir; Baysal Yildirim, Zeynep; Kuyumcu, Mahir; Gümüş, Abdurrahman; Akelma, Hakan

    2014-01-01

    Background. Sugammadex offers a good alternative to the conventional decurarisation process currently performed with cholinesterase inhibitors. Sugammadex, which was developed specifically for the aminosteroid-structured rocuronium and vecuronium neuromuscular blockers, is a modified cyclodextrin made up of 8 glucose monomers arranged in a cylindrical shape. Methods. In this study, the goal was to investigate the efficacy of sugammadex. Sugammadex was used when there was insufficient decurarisation following neostigmine. This study was performed on 14 patients who experienced insufficient decurarisation (TOF sugammadex was administered. Results. Time elapsed until sugammadex administration following neostigmine 37 ± 6 min, following sugammadex it took 2.1 ± 0.9 min to reach TOF ≥0.9, and the extubation time was 3.2 ± 1.4 min. No statistically significant differences were detected in the hemodynamic parameters before and after sugammadex application. From the time of administration of sugammadex to the second postoperative hour, no side effects or complications occurred. None of the patients experienced acute respiratory failure or residual block during this time period. Conclusion. Sugammadex was successfully used to reverse rocuronium-induced neuromuscular block in patients where neostigmine was insufficient. PMID:25202709

  10. Digital linear accelerator: The advantages for radiotherapy

    International Nuclear Information System (INIS)

    Andric, S.; Maksimovic, M.; Dekic, M.; Clark, T.

    1998-01-01

    Technical performances of Digital Linear Accelerator were presented to point out its advantages for clinical radiotherapy treatment. The accelerator installation is earned out at Military Medical Academy, Radiotherapy Department, by Medes and Elekta companies. The unit offers many technical advantages with possibility of introduction new conformal treatment techniques as stereotactic radiosurgery, total body and total skin irradiation. In the paper are underlined advantages in relation to running conventional accelerator units at Yugoslav radiotherapy departments, both from technical and medical point of view. (author)

  11. Pelletron accelerator at Panjab University Chandigarh

    International Nuclear Information System (INIS)

    Singh, Nirmal; Mehta, Devinder

    2006-01-01

    The purpose of pelletron accelerator at Panjab University is to develop a low-energy accelerator laboratory within the university infrastructure. It will be housing a tandem electrostatic accelerator. The facility will bring together the available scientific expertise from a wide range of applications, viz. medical, biological and physical sciences and engineering that utilize accelerator-based technologies and techniques. It will play an important role in promoting integrated research and education across scientific disciplines available in the campus. (author)

  12. Accelerator microanalysis

    International Nuclear Information System (INIS)

    Tuniz, C.

    1997-01-01

    Particle accelerators have been developed more than sixty years ago to investigate nuclear and atomic phenomena. A major shift toward applications of accelerators in the study of materials structure and composition in inter-disciplinary projects has been witnessed in the last two decades. The Australian Nuclear Science and Technology Organisation (ANSTO) has developed advanced research programs based on the use of particle and photon beams. Atmospheric pollution problems are investigated at the 3 MV Van de Graff accelerator using ion beam analysis techniques to detect toxic elements in aerosol particles. High temperature superconductor and semiconductor materials are characterised using the recoil of iodine and other heavy ions produced at ANTARES, the 10-MV Tandem accelerator. A heavy-ion microprobe is presently being developed at ANTARES to map elemental concentrations of specific elements with micro-size resolution. An Accelerator mass Spectrometry (AMS) system has been developed at ANSTO for the ultra-sensitive detection of Carbon-14, Iodine-129 and other long-lived radioisotopes. This AMS spectrometer is a key instrument for climate change studies and international safeguards. ANSTO is also managing the Australian Synchrotron Research program based on facilities developed at the Photon Factory (Japan) and at the Advanced Photon Source (USA). Advanced projects in biology, materials chemistry, structural condensed matter and other disciplines are being promoted by a consortium involving Australian universities and research institutions. This paper will review recent advances in the use of particle accelerators, with a particular emphasis on applications developed at ANSTO and related to problems of international concern, such as global environmental change, public health and nuclear proliferation

  13. Emergency room management of radiation accidents

    International Nuclear Information System (INIS)

    Rosenberg, R.; Mettler, F.A. Jr.

    1990-01-01

    Emergency room management of radioactively contaminated patients who have an associated medical injury requiring immediate attention must be handled with care. Radioactive contamination of the skin of a worker is not a medical emergency and is usually dealt with at the plant. Effective preplanning and on-the-scene triage will allow the seriously injured and contaminated patients to get the medical care they need with a minimum of confusion and interference. Immediate medical and surgical priorities always take precedence over radiation injuries and radioactive contamination. Probably the most difficult aspect of emergency management is the rarity of such accidents and hence the unfamiliarity of the medical staff with the appropriate procedures. The authors discuss how the answer to these problems is preplanning, having a simple and workable procedure and finally having 24-h access to experts

  14. Biological and medical research with accelerated heavy ions at the Bevalac, 1974--1977. [Planning for use for radiotherapy and as radiation source for diagnostic radiography

    Energy Technology Data Exchange (ETDEWEB)

    Elam, S. (ed.)

    1977-04-01

    The Bevalac, a versatile high-energy heavy-ion accelerator complex, has been in operation for less than two years. A major purpose for which the Bevalac was constructed was to explore the possibility of heavy-ion teams for therapy for certain forms of cancer. Significant progress has been made in this direction. The National Cancer Institute has recognized the advantages that these and other accelerated particles offer, and heavy ions have been included in a long-term plan for particle therapy that will assess by means of controlled therapeutic tests the value of various modalities. Since accelerated heavy ions became available, the possibility of other contributions, not planned, became apparent. We are developig a new diagnostic method known as heavy-ion radiography that has greatly increased sensitivity for soft-tissue detail and that may become a powerful tool for localizing early tumors and metastases. We have discovered that radioactive beams are formed from fragmentation of stable deflected beams. Use of these autoradioactive beams is just beginning; however, we know that these beams will be helpful in localizing the region in the body where therapy is being delivered. In addition, it has been demonstrated that instant implantation of the radioactive beam allows direct measurements of blood perfusion rates in inaccessible parts of the body, and such a technique may become a new tool for the study of fast hot atom reactions in biochemistry, tracer biology and nuclear medicine. The Bevalac will also be useful for the continuation of previously developed methods for the control of acromegaly, Cushing's disease and, on a research basis, advanced diabetes mellitus with vascular disease. The ability to make small bloodless lesions in the brain and elsewhere with heavy-ion beams has great potential for nervous-system studies and perhaps later for radioneurosurgery.

  15. Neutron activation processes in the medical linear accelerator Elekta Precise; Procesos de activacion neutronica en el acelerador lineal medico Elekta Precise

    Energy Technology Data Exchange (ETDEWEB)

    Juste, B.; Miro, R.; Verdu, G.; Diez, S.; Campayo, J. M.

    2015-07-01

    Monte Carlo estimation of the giant-dipole-resonance (GRN) photoneutrons insider the Elekta Precise Linac head (emitting a 15 MV photon beam) were performed using the MCNP6 code. Each component of Linac head geometry and materials were modelled in detail using the given manufacturer information. Primary photons generate photoneutrons and its transport across the treatment head was simulated, including the (n, γ) reactions which undergo activation products. The MCNP6 was used to develop a method for quantifying the activation of accelerator components. The approach described in this paper is useful in quantifying the origin and the amount of nuclear activation. (Author)

  16. Medical Applications

    CERN Document Server

    Biscari, C.

    2014-12-19

    The use of accelerators for medical applications has evolved from initial experimentation to turn-key devices commonly operating in hospitals. New applications are continuously being developed around the world, and the hadrontherapy facilities of the newest generation are placed at the frontier between industrial production and advanced R&D. An introduction to the different medical application accelerators is followed by a description of the hadrontherapy facilities, with special emphasis on CNAO, and the report closes with a brief outlook on the future of this field.

  17. Medical Applications

    International Nuclear Information System (INIS)

    Biscari, C; Falbo, L

    2014-01-01

    The use of accelerators for medical applications has evolved from initial experimentation to turn-key devices commonly operating in hospitals. New applications are continuously being developed around the world, and the hadrontherapy facilities of the newest generation are placed at the frontier between industrial production and advanced R&D. An introduction to the different medical application accelerators is followed by a description of the hadrontherapy facilities, with special emphasis on CNAO, and the report closes with a brief outlook on the future of this field

  18. The Influence of Used Construction Material and Its Thickness on the Neutron Dose Rate Around the Linear Accelerator - Experimental Results

    International Nuclear Information System (INIS)

    Krpan, I; Miklavcic, I.; Poje, M.; Radolic, V.; Vukovic, B.; Zivkovic, A.; Faj, D.; Ivkovic, A.

    2013-01-01

    Since linear accelerators for medical radiotherapy do not have active radioactive sources it makes them adequate from the radioprotection point of view. However, when operating at the energy higher than 10 MeV, they can become a source of unwanted neutron radiation in the giant dipole resonance reaction between the photon beam and the accelerator head material. Neutrons created in this reaction are almost isotropic in direction with an energy range between 700 keV and 1 MeV. During the accelerator installation and different phases of the construction work around the accelerator, a neutron dose rate at several important locations was investigated. Both passive (solid state nuclear track etched detectors - CR 39 and/or LR-115 with the 10B foil) and active detectors (Thermo Biorem FHT 752) were used. A higher photon dose rate was measured around the accelerator facility. An effective photon dose reduction was achieved using steel plates. However, this was the secondary source of neutrons in the reaction between the photons and steel plates, since higher values were measured. Neutron reduction was done by additional layers of barite concrete. A very conservative assessment of the effective dose was done for the medical personnel inside the control room. At the accelerator extreme operating regime (fixed accelerator direction - gantry angle, highest energy possible used), the neutron dose rate in the control room of 12 μSv/h was measured. Knowing the number of working days and number of patients per technician (per day), an exposure to the neutron dose of 1,1 mSv per year was calculated.(author)

  19. Clean room actuators

    Energy Technology Data Exchange (ETDEWEB)

    Higuchi, Toshiro

    1987-06-01

    This report explains on the present status of the clean room actuators including the author's research results. In a clean room, there exists a possibility of dust generation, even when a direct human work is eliminated by the use of robots or automatic machines, from the machines themselves. For this, it is important to develop such clean robots and transfer/positioning mechanism that do not generate dusts, and to develop an actuator and its control technique. Topics described in the report are as follows: 1. Prevention of dust diffusion by means of sealing. 2. Elimination of mechanical contact (Linear induction motor and pneumatic float, linear motor and magnetic attraction float, linear motor and air bearing, and magnetic bearing). 3. Contactless actuator having a positioning mechanism (Use of linear step motor and rotary contactless actuator). (15 figs, 11 refs)

  20. Parametric Room Acoustic Workflows

    DEFF Research Database (Denmark)

    Parigi, Dario; Svidt, Kjeld; Molin, Erik

    2017-01-01

    The paper investigates and assesses different room acoustics software and the opportunities they offer to engage in parametric acoustics workflow and to influence architectural designs. The first step consists in the testing and benchmarking of different tools on the basis of accuracy, speed...... and interoperability with Grasshopper 3d. The focus will be placed to the benchmarking of three different acoustic analysis tools based on raytracing. To compare the accuracy and speed of the acoustic evaluation across different tools, a homogeneous set of acoustic parameters is chosen. The room acoustics parameters...... included in the set are reverberation time (EDT, RT30), clarity (C50), loudness (G), and definition (D50). Scenarios are discussed for determining at different design stages the most suitable acoustic tool. Those scenarios are characterized, by the use of less accurate but fast evaluation tools to be used...

  1. Acidentes e violências: caracterização dos atendimentos no pronto-socorro de um hospital universitário Accidents and violence: characteristics of the medical cares in the emergency room's university hospital

    Directory of Open Access Journals (Sweden)

    José Luís Guedes dos Santos

    2008-09-01

    Full Text Available Este artigo, de caráter exploratório-descritivo, tem como objetivo caracterizar os atendimentos por acidentes e violências realizados no pronto-socorro de um hospital universitário localizado no interior do Rio Grande do Sul (RS. Os dados foram obtidos a partir dos registros de um sistema de vigilância, denominado "Observatório de Acidentes e Violência", existente nos serviços de urgência e emergência no RS, que atuam como sentinela desses agravos. Os resultados mostraram que os adultos jovens, com baixo nível de instrução e não-trabalhadores são as principais vítimas de acidentes e violências. Quanto ao tipo de ocorrência, destacaram-se os acidentes de trânsito e acidentes domésticos, gerando como agravos mais constantes ferimentos na cabeça e fraturas de fêmur. Com relação ao sexo, embora para alguns tipos de acidentes e violências a predominância tenha variado entre eles, o conjunto dos dados mostrou maior vulnerabilidade masculina, em especial nos casos de violência interpessoal. Nesse sentido, as consequências dos acidentes e violências para o sistema de saúde e para a sociedade apontam a necessidade de aprimoramento dos sistemas de informações de morbimortalidade por causas externas, visando subsidiar políticas públicas de prevenção e melhoria no atendimento às vítimas.This article, of an exploratory-descriptive character, aims to characterize the medical care provided in cases of accidents and violence in the emergency room of a university hospital, located in the interior of the state of Rio Grande do Sul (RS. The data were obtained from the registers of a monitoring system called "Observatório de Acidentes e Violência" (Observatory of Accidents and Violence, which exists in the urgency and emergency services in RS and acts as a sentry of these injuries. The results showed that young adults who are non-workers and have low schooling are the main victims of accidents and violence. The most frequent

  2. Air Distribution in Rooms

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The research on air distribution in rooms is often done as full-size investigations, scale-model investigations or by Computational Fluid Dynamics (CFD). New activities have taken place within all three areas and this paper draws comparisons between the different methods. The outcome of the l......EA sponsored research "Air Flow Pattern within Buildings" is used for comparisons in some parts of the paper because various types of experiments and many countries are involved....

  3. The Use of Online Quizlet.com Resource Tools to Support Native English Speaking Students of Engineering and Medical Departments in Accelerated RFL Teaching and Learning

    Directory of Open Access Journals (Sweden)

    Kh.E. Ismailova

    2016-05-01

    Full Text Available The paper presents a description of the methodology and some results of the application of tools of the language learning support portal Quizlet.com to improve the effectiveness of the accelerated development of the basic communicative skills in Russian as a foreign language (RFL for the group of the English-speaking students who arrived to study in Russia engineering, medicine and other areas. The application of the development is the basics of Russian teaching and learning in the classroom as well as in the mode of self-education and out-of-classroom events. Special attention is paid to the use of cloud-based tools to organize and conduct extracurricular activities. Particularly in the promising subject connected with the use of 3D printers for the solution of engineering problems of prosthetics of the lost bodies of animals and birds on the example of the Toucan key restoration. Analysis of the results of the use of flash cards, tests, and group games showed the promise of using the sets of Quizlet.com tools for accelerated assimilation of the native English speaking students in the area of General and special RFL vocabulary, as well as students showed that in a short time they can get and develop their basic skills of listening, reading and writing in Russian communication when Quizlet tools being used in different modes.

  4. Accelerator operations

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    This section is concerned with the operation of both the tandem-linac system and the Dynamitron, two accelerators that are used for entirely different research. Developmental activities associated with the tandem and the Dynamitron are also treated here, but developmental activities associated with the superconducting linac are covered separately because this work is a program of technology development in its own right

  5. CNSTN Accelerator

    International Nuclear Information System (INIS)

    Habbassi, Afifa; Trabelsi, Adel

    2010-01-01

    This project give a big idea about the measurement of the linear accelerator in the CNSTN. During this work we control dose distribution for different product. For this characterisation we have to make an installation qualification ,operational qualification,performance qualification and of course for every step we have to control temperature and the dose ,even the distribution of the last one.

  6. Accelerators course

    CERN Multimedia

    CERN. Geneva HR-RFA; Métral, E

    2006-01-01

    1a) Introduction and motivation 1b) History and accelerator types 2) Transverse beam dynamics 3a) Longitudinal beam dynamics 3b) Figure of merit of a synchrotron/collider 3c) Beam control 4) Main limiting factors 5) Technical challenges

  7. Accelerator operations

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Operations of the SuperHILAC, the Bevatron/Bevalac, and the 184-inch Synchrocyclotron during the period from October 1977 to September 1978 are discussed. These include ion source development, accelerator facilities, the Heavy Ion Spectrometer System, and Bevelac biomedical operations

  8. Planets in a Room

    Science.gov (United States)

    Giacomini, l.; Aloisi, F.; De Angelis, I.

    2017-09-01

    Teaching planetary science using a spherical projector to show the planets' surfaces is a very effective but usually very expensive idea. Whatsmore, it usually assumes the availability of a dedicated space and a trained user. "Planets in a room" is a prototypal low cost version of a small, spherical projector that teachers, museum, planetary scientists and other individuals can easily build and use on their own, to show and teach the planets The project of "Planets in a Room" was made by the italian non-profit association Speak Science with the collaboration of INAF-IAPS of Rome and the Roma Tre University (Dipartimento di Matematica e Fisica). This proposal was funded by the Europlanet Outreach Funding Scheme in 2016. "Planets in a room" will be presented during EPSC 2017 to give birth to the second phase of the project, when the outreach and research community will be involved and schools from all over Europe will be invited to participate with the aim of bringing planetary science to a larger audience.

  9. Accelerator update

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    When the Accelerator Conference, combined International High Energy and US Particle versions, held in Dallas in May, was initially scheduled, progress nearby for the US Superconducting Supercollider was high on the preliminary agenda. With the SSC voted down by Congress in October 1993, this was no longer the case. However the content of the meeting, in terms of both its deep implications for ambitious new projects and the breadth of its scope, showed that the worldwide particle accelerator field is far from being moribund. A traditional feature of such accelerator conferences is the multiplicity of parallel sessions. No one person can attend all sessions, so that delegates can follow completely different paths and emerge with totally different impressions. Despite this overload, and despite the SSC cancellation, the general picture is one of encouraging progress over a wide range of major new projects throughout the world. At the same time, spinoff from, and applications of, accelerators and accelerator technology are becoming increasingly important. Centrestage is now CERN's LHC proton-proton collider, where a test string of superconducting magnets is operating over long periods at the nominal LHC field of 8.36 tesla or more. The assignment of the underground areas in the existing 27- kilometre LEP tunnel is now quasidefinitive (see page 3). For CERN's existing big machine, the LEP electron-positron collider, ongoing work concentrates on boosting performance using improved optics and bunch trains. But the main objective is the LEP2 scheme using superconducting accelerating cavities to boost the beam energy (see page 6). After some initial teething problems, production and operation of these cavities appears to have been mastered, at least under test conditions. A highlight at CERN last year was the first run with lead ions (December 1994, page 15). Handling these heavy particles with systems originally designed for protons calls for ingenuity. The SPS

  10. Accelerator update

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1995-09-15

    When the Accelerator Conference, combined International High Energy and US Particle versions, held in Dallas in May, was initially scheduled, progress nearby for the US Superconducting Supercollider was high on the preliminary agenda. With the SSC voted down by Congress in October 1993, this was no longer the case. However the content of the meeting, in terms of both its deep implications for ambitious new projects and the breadth of its scope, showed that the worldwide particle accelerator field is far from being moribund. A traditional feature of such accelerator conferences is the multiplicity of parallel sessions. No one person can attend all sessions, so that delegates can follow completely different paths and emerge with totally different impressions. Despite this overload, and despite the SSC cancellation, the general picture is one of encouraging progress over a wide range of major new projects throughout the world. At the same time, spinoff from, and applications of, accelerators and accelerator technology are becoming increasingly important. Centrestage is now CERN's LHC proton-proton collider, where a test string of superconducting magnets is operating over long periods at the nominal LHC field of 8.36 tesla or more. The assignment of the underground areas in the existing 27- kilometre LEP tunnel is now quasidefinitive (see page 3). For CERN's existing big machine, the LEP electron-positron collider, ongoing work concentrates on boosting performance using improved optics and bunch trains. But the main objective is the LEP2 scheme using superconducting accelerating cavities to boost the beam energy (see page 6). After some initial teething problems, production and operation of these cavities appears to have been mastered, at least under test conditions. A highlight at CERN last year was the first run with lead ions (December 1994, page 15). Handling these heavy particles with systems originally designed for protons calls for ingenuity. The SPS has managed

  11. Review of Advanced Accelerator Concepts R & D in Japan

    Science.gov (United States)

    Kitagawa, Yoneyoshi; Uesaka, Mitsuru; Koyama, Kazuyoshi; Nakajima, Kaszuhisa; Tajima, Toshiki; Daido, Hiroyuki; Ogata, Atsushi; Nemoto, Koshichi; Nishida, Yasushi; Yugami, Noboru; Miyamoto, Shuji; Dobashi, Katsuhiro

    2004-12-01

    More than 15 Japanese laboratories are dedicated to the advanced and compact accelerator development. Some use ultra-intense lasers and others use microwave concepts. As for the laser electron accleration, the topics are the capillary acceleration and the mono-energetic acceleration. The laser ion acceleration is also active. As well, the compatization is proceeding of the current rf accelerator. The National Institute for Radiological Science is promoting an advanced accelerator concept project mainly for the medical application.

  12. [Management for the operating room].

    Science.gov (United States)

    Tschudi, O; Schüpfer, G

    2015-03-01

    Business companies, which in the current times also includes hospitals, must create customer benefits and as a prerequisite for this must sustainably generate profits. Management in the world of business means the formation and directing of a company or parts of a company on a permanent basis, whereby management in this context is not exercising power but function. This concept of management is exemplary developed in this article for the important services sector of the operating room (OR) and individual functions, such as resource control, capacity planning and materials administration are presented in detail. Some OR-specific management challenges are worked out. From this it becomes clear that the economic logic of the most efficient implementation possible is not a contradiction of medical ethics, enabling the most effective treatment possible for patients while safeguarding the highest possible levels of safety and quality. The article aims to build a bridge for medical specialists to the language and world of commerce, emphasizing the profession-based competence and hopefully to arouse interest to go into more detail.

  13. Continuity of Accelerator Operations during an Extended Pandemic

    International Nuclear Information System (INIS)

    Noel Okay

    2010-01-01

    The Operations group for the Continuous Electron Accelerator Facility in Newport News Virginia has developed a Continuity of Operations plan for pandemic conditions when high absenteeism may impact accelerator control room operations. Protocols to address both the potential spread of illnesses in the control room environment as well as maintaining minimum staffing requirements for contiguous accelerator operation will be presented. During acute pandemic conditions local government restrictions may prevent continued operations but during extended periods of high absenteeism accelerator operations can continue when some added precautionary measures and staffing adjustments are made in the way business is done.

  14. Game theory: applications for surgeons and the operating room environment.

    Science.gov (United States)

    McFadden, David W; Tsai, Mitchell; Kadry, Bassam; Souba, Wiley W

    2012-11-01

    Game theory is an economic system of strategic behavior, often referred to as the "theory of social situations." Very little has been written in the medical literature about game theory or its applications, yet the practice of surgery and the operating room environment clearly involves multiple social situations with both cooperative and non-cooperative behaviors. A comprehensive review was performed of the medical literature on game theory and its medical applications. Definitive resources on the subject were also examined and applied to surgery and the operating room whenever possible. Applications of game theory and its proposed dilemmas abound in the practicing surgeon's world, especially in the operating room environment. The surgeon with a basic understanding of game theory principles is better prepared for understanding and navigating the complex Operating Room system and optimizing cooperative behaviors for the benefit all stakeholders. Copyright © 2012 Mosby, Inc. All rights reserved.

  15. Room with a View: Ethical Encounters in Room 13

    Science.gov (United States)

    Grube, Vicky

    2012-01-01

    In this article, the author describes ethical encounters in Room 13, a schoolroom where children made what they wanted, posed their own questions, and ran an art room like a small business. In Room 13 children had the responsibility to maintain all aspects of the art studio. Specific decisions fell to an annually elected management team, a small…

  16. Advanced accelerator and mm-wave structure research at LANL

    Energy Technology Data Exchange (ETDEWEB)

    Simakov, Evgenya Ivanovna [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-22

    This document outlines acceleration projects and mm-wave structure research performed at LANL. The motivation for PBG research is described first, with reference to couplers for superconducting accelerators and structures for room-temperature accelerators and W-band TWTs. These topics are then taken up in greater detail: PBG structures and the MIT PBG accelerator; SRF PBG cavities at LANL; X-band PBG cavities at LANL; and W-band PBG TWT at LANL. The presentation concludes by describing other advanced accelerator projects: beam shaping with an Emittance Exchanger, diamond field emitter array cathodes, and additive manufacturing of novel accelerator structures.

  17. A high-protein diet during hospitalization is associated with an accelerated decrease in soluble urokinase plasminogen activator receptor levels in acutely ill elderly medical patients with SIRS

    DEFF Research Database (Denmark)

    Tavenier, Juliette; Haupt, Thomas Huneck; Andersen, Aino L

    2017-01-01

    inflammation in healthy elderly. We hypothesized that nutritional support and resistance training would accelerate the resolution of inflammation in hospitalized elderly patients with SIRS. Acutely admitted patients aged >65 years with SIRS were randomized to an intervention consisting of a high-protein diet...... (1.7 g/kg per day) during hospitalization, and daily protein supplement (18.8 g) and 3 weekly resistance training sessions for 12 weeks after discharge (Intervention, n=14), or to standard-care (Control, n=15). Plasma levels of the inflammatory biomarkers soluble urokinase plasminogen activator...... receptor (suPAR), interleukin-6, C-reactive protein (CRP), and albumin were measured at admission, discharge, and 4 and 13 weeks after discharge. The Intervention group had an earlier decrease in suPAR levels than the Control group: -15.4% vs. +14.5%, P=.007 during hospitalization, and -2.4% vs. -28.6%, P...

  18. Study on the photoneutrons produced in 15 MV medical linear accelerators : Comparison of three dimensional conformal radiotherapy and intensity modulated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Oh Nam [Gangneung Asan Hospital, Gangneung (Korea, Republic of); Yang, Oh Nam; Lim, Cheong Hwan [Hanseo Univ., Seosan (Korea, Republic of)

    2012-12-15

    Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photoneutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photon beams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose.

  19. Study on the photoneutrons produced in 15 MV medical linear accelerators : Comparison of three dimensional conformal radiotherapy and intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Yang, Oh Nam; Yang, Oh Nam; Lim, Cheong Hwan

    2012-01-01

    Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photoneutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photon beams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose

  20. IFMIF accelerators design

    International Nuclear Information System (INIS)

    Mosnier, A.; Ratzinger, U.

    2008-01-01

    The IFMIF requirement for 250 mA current of deuteron beams at a nominal energy of 40 MeV is met by means of two identical continuous wave (CW) 175 MHz linear accelerators running in parallel, each delivering a 125 mA, 40 MeV deuteron beam to the common target. This approach allows to stay within the current capability of present RF linac technology while providing operational redundancy in case of failure of one of the linacs. Each linac comprises a sequence of acceleration and beam transport/matching stages. The ion source generates a 140 mA deuteron beam at 100 keV. A low energy beam transport (LEBT) transfers the deuteron beam from the source to a radio frequency quadrupole (RFQ) cavity. The RFQ bunches and accelerates the 125 mA beam to 5 MeV. The RFQ output beam is injected through a matching section into a drift-tube-linac (DTL) where it is accelerated to the final energy of 40 MeV. In the reference design, the final acceleration stage is a conventional Alvarez-type DTL with post-couplers operating at room temperature. Operation of both the RFQ and the DTL at the same relatively low frequency is essential for accelerating the high current deuteron beam with low beam loss. The primary concern of the IFMIF linacs is the minimization of beam losses, which could limit their availability and maintainability due to excessive activation of the linac and irradiation of the environment. A careful beam dynamics design is therefore needed from the source to the target to avoid the formation of particle halo that could finally be lost in the linac or transfer lines. A superconducting solution for the high energy portion of the linac using, for example, CH-structure or coaxial-type resonators, could offer some advantages, in particular the reduction of operational costs. Careful beam dynamics simulations and comparison tests with beam during the EVEDA phase are however necessary in order to fully assess the technical feasibility of such alternative solutions

  1. Accelerating Value Creation with Accelerators

    DEFF Research Database (Denmark)

    Jonsson, Eythor Ivar

    2015-01-01

    and developing the best business ideas and support the due diligence process. Even universities are noticing that the learning experience of the action learning approach is an effective way to develop capabilities and change cultures. Accelerators related to what has historically been associated...

  2. Post-accelerator LINAC design for the VECC RIB project

    Indian Academy of Sciences (India)

    acclerator type of RIB facility. The scheme utilises the existing = 130 room temperature variable energy cyclotron machine as the primary accelerator for the production of RIBs and radio frequency quadrupole (RFQ) and LINAC modules for ...

  3. Ergonomics in the operating room.

    Science.gov (United States)

    Janki, Shiromani; Mulder, Evalyn E A P; IJzermans, Jan N M; Tran, T C Khe

    2017-06-01

    Since the introduction of minimally invasive surgery, surgeons appear to be experiencing more occupational musculoskeletal injuries. The aim of this study is to investigate the current frequency and effects of occupational musculoskeletal injuries on work absence. An online questionnaire was conducted among all surgeons affiliated to the Dutch Society for Endoscopic Surgery, Gastrointestinal Surgery, and Surgical Oncology. In addition, this survey was conducted among surgeons, gynaecologists, and urologists of one cluster of training hospitals in the Netherlands. There were 127 respondents. Fifty-six surgeons currently suffer from musculoskeletal complaints, and 30 have previously suffered from musculoskeletal complaints with no current complaints. Frequently reported localizations were the neck (39.5 %), the erector spinae muscle (34.9 %), and the right deltoid muscle (18.6 %). Most of the musculoskeletal complaints were present while operating (41.8 %). Currently, 37.5 % uses medication and/or therapy to reduce complaints. Of surgeons with past complaints, 26.7 % required work leave and 40.0 % made intraoperative adjustments. More surgeons with a medical history of musculoskeletal complaints have current complaints (OR 6.1, 95 % CI 1.9-19.6). There were no significant differences between surgeons of different operating techniques in localizations and frequency of complaints, or work leave. Despite previous various ergonomic recommendations in the operating room, the current study demonstrated that musculoskeletal complaints and subsequent work absence are still present among surgeons, especially among surgeons with a positive medical history for musculoskeletal complaints. Even sick leave was necessary to fully recover. There were no significant differences in reported complaints between surgeons of different operating techniques. Almost half of the respondents with complaints made intraoperative ergonomic adjustments to prevent future complaints. The

  4. The radiation field measurement and analysis outside the shielding of A 10 MeV electron irradiation accelerator

    Science.gov (United States)

    Shang, Jing; Li, Juexin; Xu, Bing; Li, Yuxiong

    2011-10-01

    Electron accelerators are employed widely for diverse purposes in the irradiation-processing industry, from sterilizing medical products to treating gemstones. Because accelerators offer high efficiency, high power, and require little preventative maintenance, they are becoming more and more popular than using the 60Co isotope approach. However, the electron accelerator exposes potential radiation hazards. To protect workers and the public from exposure to radiation, the radiation field around the electronic accelerator must be assessed, especially that outside the shielding. Thus, we measured the radiation dose at different positions outside the shielding of a 10-MeV electron accelerator using a new data-acquisition unit named Mini-DDL (Mini-Digital Data Logging). The measurements accurately reflect the accelerator's radiation status. In this paper, we present our findings, results and compare them with our theoretical calculations. We conclude that the measurements taken outside the irradiation hall are consistent with the findings from our calculations, except in the maze outside the door of the accelerator room. We discuss the reason for this discrepancy.

  5. The radiation field measurement and analysis outside the shielding of A 10 MeV electron irradiation accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Shang Jing [National Synchrotron Radiation Lab, University of Science and Technology of China (China); Li Juexin, E-mail: juexin@ustc.edu.cn [National Synchrotron Radiation Lab, University of Science and Technology of China (China); Xu Bing; Li Yuxiong [National Synchrotron Radiation Lab, University of Science and Technology of China (China)

    2011-10-01

    Electron accelerators are employed widely for diverse purposes in the irradiation-processing industry, from sterilizing medical products to treating gemstones. Because accelerators offer high efficiency, high power, and require little preventative maintenance, they are becoming more and more popular than using the {sup 60}Co isotope approach. However, the electron accelerator exposes potential radiation hazards. To protect workers and the public from exposure to radiation, the radiation field around the electronic accelerator must be assessed, especially that outside the shielding. Thus, we measured the radiation dose at different positions outside the shielding of a 10-MeV electron accelerator using a new data-acquisition unit named Mini-DDL (Mini-Digital Data Logging). The measurements accurately reflect the accelerator's radiation status. In this paper, we present our findings, results and compare them with our theoretical calculations. We conclude that the measurements taken outside the irradiation hall are consistent with the findings from our calculations, except in the maze outside the door of the accelerator room. We discuss the reason for this discrepancy.

  6. Safety measures in exposure room

    International Nuclear Information System (INIS)

    Muhammad Jamal Md Isa

    2004-01-01

    The contents of this chapter are follows - The exposure room: location and dimension, material and thickness, windows, doors and other openings; Position of the Irradiating Apparatus, Use of Space Adjoining the Room, Warning Signs/Light, Dark Room. Materials and Apparatus: Classification of Areas, Local Rules, Other General Safety Requirements

  7. Prospects for Accelerator Technology

    Science.gov (United States)

    Todd, Alan

    2011-02-01

    Accelerator technology today is a greater than US$5 billion per annum business. Development of higher-performance technology with improved reliability that delivers reduced system size and life cycle cost is expected to significantly increase the total accelerator technology market and open up new application sales. Potential future directions are identified and pitfalls in new market penetration are considered. Both of the present big market segments, medical radiation therapy units and semiconductor ion implanters, are approaching the "maturity" phase of their product cycles, where incremental development rather than paradigm shifts is the norm, but they should continue to dominate commercial sales for some time. It is anticipated that large discovery-science accelerators will continue to provide a specialty market beset by the unpredictable cycles resulting from the scale of the projects themselves, coupled with external political and economic drivers. Although fraught with differing market entry difficulties, the security and environmental markets, together with new, as yet unrealized, industrial material processing applications, are expected to provide the bulk of future commercial accelerator technology growth.

  8. Laser acceleration

    Science.gov (United States)

    Tajima, T.; Nakajima, K.; Mourou, G.

    2017-02-01

    The fundamental idea of Laser Wakefield Acceleration (LWFA) is reviewed. An ultrafast intense laser pulse drives coherent wakefield with a relativistic amplitude robustly supported by the plasma. While the large amplitude of wakefields involves collective resonant oscillations of the eigenmode of the entire plasma electrons, the wake phase velocity ˜ c and ultrafastness of the laser pulse introduce the wake stability and rigidity. A large number of worldwide experiments show a rapid progress of this concept realization toward both the high-energy accelerator prospect and broad applications. The strong interest in this has been spurring and stimulating novel laser technologies, including the Chirped Pulse Amplification, the Thin Film Compression, the Coherent Amplification Network, and the Relativistic Mirror Compression. These in turn have created a conglomerate of novel science and technology with LWFA to form a new genre of high field science with many parameters of merit in this field increasing exponentially lately. This science has triggered a number of worldwide research centers and initiatives. Associated physics of ion acceleration, X-ray generation, and astrophysical processes of ultrahigh energy cosmic rays are reviewed. Applications such as X-ray free electron laser, cancer therapy, and radioisotope production etc. are considered. A new avenue of LWFA using nanomaterials is also emerging.

  9. Laser acceleration

    International Nuclear Information System (INIS)

    Tajima, T.; Nakajima, K.; Mourou, G.

    2017-01-01

    The fundamental idea of LaserWakefield Acceleration (LWFA) is reviewed. An ultrafast intense laser pulse drives coherent wakefield with a relativistic amplitude robustly supported by the plasma. While the large amplitude of wake fields involves collective resonant oscillations of the eigenmode of the entire plasma electrons, the wake phase velocity ∼ c and ultra fastness of the laser pulse introduce the wake stability and rigidity. A large number of worldwide experiments show a rapid progress of this concept realization toward both the high-energy accelerator prospect and broad applications. The strong interest in this has been spurring and stimulating novel laser technologies, including the Chirped Pulse Amplification, the Thin Film Compression, the Coherent Amplification Network, and the Relativistic Mirror Compression. These in turn have created a conglomerate of novel science and technology with LWFA to form a new genre of high field science with many parameters of merit in this field increasing exponentially lately. This science has triggered a number of worldwide research centers and initiatives. Associated physics of ion acceleration, X-ray generation, and astrophysical processes of ultrahigh energy cosmic rays are reviewed. Applications such as X-ray free electron laser, cancer therapy, and radioisotope production etc. are considered. A new avenue of LWFA using nano materials is also emerging.

  10. Accelerating networks

    International Nuclear Information System (INIS)

    Smith, David M D; Onnela, Jukka-Pekka; Johnson, Neil F

    2007-01-01

    Evolving out-of-equilibrium networks have been under intense scrutiny recently. In many real-world settings the number of links added per new node is not constant but depends on the time at which the node is introduced in the system. This simple idea gives rise to the concept of accelerating networks, for which we review an existing definition and-after finding it somewhat constrictive-offer a new definition. The new definition provided here views network acceleration as a time dependent property of a given system as opposed to being a property of the specific algorithm applied to grow the network. The definition also covers both unweighted and weighted networks. As time-stamped network data becomes increasingly available, the proposed measures may be easily applied to such empirical datasets. As a simple case study we apply the concepts to study the evolution of three different instances of Wikipedia, namely, those in English, German, and Japanese, and find that the networks undergo different acceleration regimes in their evolution

  11. Room for a rethink?

    Energy Technology Data Exchange (ETDEWEB)

    Walker, S. [Independent Editorial and Technical Services, Oxford (United Kingdom)

    2000-05-01

    Room-and-pillar has traditionally satisfied the need for a low-cost, flexible coal mining system. Its downside can be low resource recovery. With accessible reserves falling steadily, can mining companies afford to accept this? Simon Walker looks into this problem using evidence presented recently on the US experience by Richard Bonskorski of the US Energy Information Administration, Dr Michael Karmis of Virgina Tech, Roger O'Quinn from Eimco, an equipment manufacturer, and Larry Howe from J H Fletcher. An urgent need is identified to develop new systems to allow significant gains in extraction, using novel concepts such as remote mining. 2 refs., 1 fig., 4 photos.

  12. Room for improvement

    DEFF Research Database (Denmark)

    Sandal, Louise F; Thorlund, Jonas B; Moore, Andrew J

    2018-01-01

    -reported outcomes and qualitative findings supported the primary finding, while improvements in muscle strength and aerobic capacity did not differ between exercise groups. CONCLUSION: Results suggest that the physical environment contributes to treatment response. Matching patients' preferences to treatment rooms...... significance (p=0.07). Waitlist group reported no improvement (-0.05 95% CI -0.5 to 0.4). In interviews, participants from the standard environment expressed greater social cohesion and feeling at home. Qualitative themes identified; reflection, sense of fellowship and transition. Secondary patient...... may improve patient-reported outcomes. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov identifier: NCT02043613....

  13. Making room for volunteers

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Kleis

    2012-01-01

    If campaigns do not accommodate this view, all but a hard core of regulars and fired-up partisans will drift away, leaving it for staffers and hired hands to do all the hard work of identifying voters, canvassing people by foot and by phone, and turning out the vote. [...] ironically, a campaign...... that is singleminded in its instrumental pursuit of victory can thus be less effective than one that is more accommodating- a campaign that makes room for volunteers by accepting that, unlike staffers, they come to politics with a different perspective and conception of what is and ought to be going on....

  14. On The Living Room

    Directory of Open Access Journals (Sweden)

    Thomas Richards

    2013-03-01

    Full Text Available This text discusses the work The Living Room, directed by the author, and reflects on its meanings and functions. The article confronts problems performance raises in relation to contemporary social life, bringing forward the isolation of life today and the possibilities performance offers to fight it. We problematise the crisis experienced by the author and the consequent creation of the work as a mobile performative device in relation to the staging space. Finally, the work questions the forms of interaction and type of participation possible in performance.

  15. Accelerator mass spectrometry and associated facilities at Inter-University Accelerator Centre, New Delhi, India

    International Nuclear Information System (INIS)

    Kumar, Pankaj; Bohra, Archna; Ojha, S.; Gargari, S.; Joshi, R.; Roonwal, G.S.; Chopra, S.; Pattanaik, J.K.; Balakrishnan, S.

    2011-01-01

    Accelerator Mass Spectrometry (AMS) facility at Inter-University Accelerator Centre (IUAC) is developed by upgrading its existing 15UD Pelletron accelerator. Since last two decades Pelletron is mainly used for nuclear physics, materials science, atomic physics, radiation biology and accelerator mass spectrometry is recent development. In addition, a chemistry laboratory in clean room for the chemical processing of samples for AMS studies has also been established. At present the AMS facility is used for 10 Be, 26 Al measurements and soon other long lived radio-isotopes will also be used

  16. Impact of healthcare design on patients' perception of a rheumatology outpatient infusion room

    DEFF Research Database (Denmark)

    Bukh, Gunhild; Tommerup, Anne Marie Munk; Madsen, Ole Rintek

    2015-01-01

    Evidence-based healthcare design is a concept aimed at reducing stress factors in the physical environment for the benefit of patients and the medical staff. The objective of this study was to examine the impact of room modifications on patients' perception of an outpatient infusion room used...... the potential to improve patients' perception of outpatient infusion rooms used for treating rheumatologic diseases....

  17. Accelerators and superconductivity: A marriage of convenience

    International Nuclear Information System (INIS)

    Wilson, M.

    1987-01-01

    This lecture deals with the relationship between accelerator technology in high-energy-physics laboratories and the development of superconductors. It concentrates on synchrotron magnets, showing how their special requirements have brought about significant advances in the technology, particularly the development of filamentary superconducting composites. Such developments have made large superconducting accelerators an actuality: the Tevatron in routine operation, the Hadron Electron Ring Accelerator (HERA) under construction, and the Superconducting Super Collider (SSC) and Large Hadron Collider (LHC) at the conceptual design stage. Other applications of superconductivity have also been facilitated - for example medical imaging and small accelerators for industrial and medical use. (orig.)

  18. Advanced concepts for acceleration

    International Nuclear Information System (INIS)

    Keefe, D.

    1986-07-01

    Selected examples of advanced accelerator concepts are reviewed. Such plasma accelerators as plasma beat wave accelerator, plasma wake field accelerator, and plasma grating accelerator are discussed particularly as examples of concepts for accelerating relativistic electrons or positrons. Also covered are the pulsed electron-beam, pulsed laser accelerator, inverse Cherenkov accelerator, inverse free-electron laser, switched radial-line accelerators, and two-beam accelerator. Advanced concepts for ion acceleration discussed include the electron ring accelerator, excitation of waves on intense electron beams, and two-wave combinations

  19. The ATOMKI Accelerator Center

    International Nuclear Information System (INIS)

    Biri, S.; Kormany, Z.; Berzi, I.; Hunyadi, M.

    2009-01-01

    for the old units. This results in major simplifications in the construction, operation and maintenance of the involved power supplies. After successful trial operation with the prototype four new units were built. Four original units in the first rack of the beamlines power supply system (belonging to the first two quadrupole doublets) were replaced with the new ones. During the last two months of the operation in 2009 these new units were used and they performed excellently under real working conditions. VdG-5 and VdG-1 machines. The 5 MV Van de Graaff accelerator (VdG- 5) was at service nearly throughout the year. The net beamtime was 1601 hours, mainly proton particles were accelerated (99%). There was little need (1%) for 4 He + particles. The beam time was distributed among the different research subjects as shown in Table 3. The typical energy range of the ion-beam per research subjects were: Nuclear physics 0.8 MeV-1.3 MeV; Nuclear astrophysics 0.8 MeV-3.6 MeV; Analytical studies 2 MeV; Micromachining 0.8 MeV-2 MeV. We had a three week break-down in October. During that time we repaired the broken parts and performed all the maintenance work that is needed periodically. We replaced some parts of the ion-source, repaired the prefocus power supply, and carried the maintenance work of the belt driving system out (including replacing some of the special bearings and greasing). This maintenance did not cause any problem to the users. In 2009 the VdG- 1 machine was not used however it was available for users. During the year the preparation of a complicated measurement was carried out in the target room. The measurement itself is scheduled in 2010. Tandetron installation. The tandetron is a used accelerator given as a gift to our institute years ago. For some technical difficulties it is still under assembling so there has not been operation experience about this accelerator in 2009 yet.

  20. Accelerators and the Accelerator Community

    Energy Technology Data Exchange (ETDEWEB)

    Malamud, Ernest; Sessler, Andrew

    2008-06-01

    In this paper, standing back--looking from afar--and adopting a historical perspective, the field of accelerator science is examined. How it grew, what are the forces that made it what it is, where it is now, and what it is likely to be in the future are the subjects explored. Clearly, a great deal of personal opinion is invoked in this process.

  1. Accelerators and the Accelerator Community

    International Nuclear Information System (INIS)

    Malamud, Ernest; Sessler, Andrew

    2008-01-01

    In this paper, standing back--looking from afar--and adopting a historical perspective, the field of accelerator science is examined. How it grew, what are the forces that made it what it is, where it is now, and what it is likely to be in the future are the subjects explored. Clearly, a great deal of personal opinion is invoked in this process

  2. A history of radiation shielding of x-ray therapy rooms

    International Nuclear Information System (INIS)

    McGinley, P.H.; Miner, M.S.

    1996-01-01

    In this report the history of shielding for radiation treatment rooms is traced from the time of the discovery of x rays to the present. During the early part of the twentieth century the hazards from ionizing radiation were recognized and the use of lead and other materials became common place for shielding against x rays. Techniques for the calculation of the shield thickness needed for x ray protection were developed in the 1920's, and shielding materials were characterized in terms of the half value layer or simple exponential factors. At the same time, better knowledge of the interaction between radiation and matter was acquired. With the development of high energy medical accelerators after 1940, new and more complex shielding problems had to be addressed. Recently, shielding requirements have become more stringent as standards for exposure of personnel and the general public have been reduced. The art of shielding of radiation treatment facilities is still being developed, and the need for a revision of the reports on shielding of medical accelerators from the National Council on Radiation Protection and Measurements is emphasized in this article. (author). 61 Refs., 3 Tabs

  3. Foucault could have been an operating room nurse.

    Science.gov (United States)

    Riley, Robin; Manias, Elizabeth

    2002-08-01

    Operating room nursing is an under-researched area of nursing practice. The stereotypical image of operating room nursing is one of task- and technically-orientated aspects of practice, where nurses work in a medical model and are dominated by constraints from outside their sphere of influence. This paper explores the possibility of understanding operating room nursing in a different way. Using the work of Michel Foucault to analyse the work of operating room nursing, this paper argues the relevance of the framework for a more in-depth analysis of this specialty area of practice. The concepts of power, discipline and subjectivity are used to demonstrate how operating room nursing is constructed as a discipline and how operating room nurses act to govern and construct the specialty. Exemplars are drawn from extensive professional experience, from guidelines of professional operating room nursing associations, as well as published texts. The focus is predominantly on the regulation of space and time to maintain the integrity of the sterile surgical field and issues of management, as well as the use of the ethical concept of the 'surgical conscience'. This form of analysis provides a level and depth of inquiry that has rarely been undertaken in operating room nursing. As such, it has the potential to provide a much needed, different view of operation room nursing that can only help to strengthen its professional foundations and development.

  4. Characterization of the neutron spectra at the final of the installations labyrinth with medical accelerators; Caracterizacion del espectro de neutrones al final del laberinto de instalaciones con aceleradores medicos

    Energy Technology Data Exchange (ETDEWEB)

    Carelli, J.; Cruzate, J.A.; Gregori, B.; Papadopulos, S.; Discacciatti, A. [Autoridad Reguladora Nuclear, Av. del Libertador 8250, Buenos Aires (Argentina)]. e-mail: jcarelli@cae.arn.gov.ar

    2006-07-01

    A linear electron accelerator for medical use is an equipment dedicated to the production of collimated beams of electrons and/or photons. In an accelerator of a bigger potential or equal to 6 MV, are produced neutrons starting from the reaction (gamma, n) due to the interaction of the photons with the materials that compose the headset and the target. In this work the theoretical and experimental studies carried out to characterize the neutron spectra to the exit of the labyrinth of three bunkers of different geometry with accelerators of 15 MV, with the purpose of evaluating the effective dose of the occupationally exposure personnel are presented. It was carried out the simulation of the neutron transport with the MCNPX code and the ENDF/B - VI library. With the objective of analyzing the variables that affect the spectral distribution the bunkers of two existent facilities in Argentina were modeled. It was considered a isotropic punctual source located in the supposed position of the target. The spectra of {sup 252} Cf and of Watt of 1.8 MeV of half energy were simulated. The election of the sources was based on published works that suppose initial neutron sources with half energy between 1.8 and 2.3 MeV for accelerators of 15 at 25 MV. Its were considered headsets of different dimensions, with and without phantom of water disperser in the patient's position and several field dimensions in the isocenter. The spectral distribution doesn't present significant differences in the different modeling situations. Its were carried out measurements, with the multisphere spectrometric system based on twelve polyethylene spheres and a spherical detector of {sup 3} He, to the exit of each one of the bunkers. It was carried out the convolution of the spectrum using the MXD{sub F}C33 code (of the UMG33 set), considering as initial spectrum that of the fission type (inverse of the energy). The obtained spectra and the environmental equivalent dose rate in each case

  5. Ring accelerators

    International Nuclear Information System (INIS)

    Gisler, G.; Faehl, R.

    1983-01-01

    We present two-dimensional simulations in (r-z) and r-theta) cylinderical geometries of imploding-liner-driven accelerators of rings of charged particles. We address issues of azimuthal and longitudinal stability of the rings. We discuss self-trapping designs in which beam injection and extraction is aided by means of external cusp fields. Our simulations are done with the 2-1/2-D particle-in-cell plasma simulation code CLINER, which combines collisionless, electromagnetic PIC capabilities with a quasi-MHD finite element package

  6. accelerating cavity

    CERN Multimedia

    On the inside of the cavity there is a layer of niobium. Operating at 4.2 degrees above absolute zero, the niobium is superconducting and carries an accelerating field of 6 million volts per metre with negligible losses. Each cavity has a surface of 6 m2. The niobium layer is only 1.2 microns thick, ten times thinner than a hair. Such a large area had never been coated to such a high accuracy. A speck of dust could ruin the performance of the whole cavity so the work had to be done in an extremely clean environment.

  7. Menopause accelerates biological aging

    Science.gov (United States)

    Levine, Morgan E.; Lu, Ake T.; Chen, Brian H.; Hernandez, Dena G.; Singleton, Andrew B.; Ferrucci, Luigi; Bandinelli, Stefania; Salfati, Elias; Manson, JoAnn E.; Quach, Austin; Kusters, Cynthia D. J.; Kuh, Diana; Wong, Andrew; Teschendorff, Andrew E.; Widschwendter, Martin; Ritz, Beate R.; Absher, Devin; Assimes, Themistocles L.; Horvath, Steve

    2016-01-01

    Although epigenetic processes have been linked to aging and disease in other systems, it is not yet known whether they relate to reproductive aging. Recently, we developed a highly accurate epigenetic biomarker of age (known as the “epigenetic clock”), which is based on DNA methylation levels. Here we carry out an epigenetic clock analysis of blood, saliva, and buccal epithelium using data from four large studies: the Women's Health Initiative (n = 1,864); Invecchiare nel Chianti (n = 200); Parkinson's disease, Environment, and Genes (n = 256); and the United Kingdom Medical Research Council National Survey of Health and Development (n = 790). We find that increased epigenetic age acceleration in blood is significantly associated with earlier menopause (P = 0.00091), bilateral oophorectomy (P = 0.0018), and a longer time since menopause (P = 0.017). Conversely, epigenetic age acceleration in buccal epithelium and saliva do not relate to age at menopause; however, a higher epigenetic age in saliva is exhibited in women who undergo bilateral oophorectomy (P = 0.0079), while a lower epigenetic age in buccal epithelium was found for women who underwent menopausal hormone therapy (P = 0.00078). Using genetic data, we find evidence of coheritability between age at menopause and epigenetic age acceleration in blood. Using Mendelian randomization analysis, we find that two SNPs that are highly associated with age at menopause exhibit a significant association with epigenetic age acceleration. Overall, our Mendelian randomization approach and other lines of evidence suggest that menopause accelerates epigenetic aging of blood, but mechanistic studies will be needed to dissect cause-and-effect relationships further. PMID:27457926

  8. Resonant coupling applied to superconducting accelerator structures

    International Nuclear Information System (INIS)

    Potter, James M.; Krawczyk, Frank L.

    2013-01-01

    The concept of resonant coupling and the benefits that accrue from its application is well known in the world of room temperature coupled cavity linacs. Design studies show that it can be applied successfully between sections of conventional elliptical superconducting coupled cavity accelerator structures and internally to structures with spoked cavity resonators. The coupling mechanisms can be designed without creating problems with high field regions or multipactoring. The application of resonant coupling to superconducting accelerators eliminates the need for complex cryogenic mechanical tuners and reduces the time needed to bring a superconducting accelerator into operation.

  9. Accelerator Physics for ILC and CLIC

    CERN Document Server

    Zimmermann, F

    2010-01-01

    This paper summarizes the second part of the “accelerator physics lectures” delivered at the Ambleside Linear Collider School 2009. It discusses more specific linear-collider issues: superconducting and room-temperature linear accelerators, particle sources for electrons and positrons, synchrotron radiation and damping, intensity limits, beam stability, and beam delivery system – including final focus, collimation, and beam-beam effects. It also presents an overview of the International Linear Collider (ILC), a description of the two beam acceleration scheme of the Compact Linear Collider (CLIC), and a comparison of the ILC and CLIC parameters.

  10. An MLC-based version for the ecliptic method for the determination of backscatter into the beam monitor chambers in photon beams of medical accelerators

    International Nuclear Information System (INIS)

    Nelli, Flavio Enrico

    2016-01-01

    A very simple method to measure the effect of the backscatter from secondary collimators into the beam monitor chambers in linear accelerators equipped with multi-leaf collimators (MLC) is presented here. The backscatter to the monitor chambers from the upper jaws of the secondary collimator was measured on three beam-matched linacs by means of three methods: this new methodology, the ecliptic method, and assessing the variation of the beam-on time per monitor unit with dose rate feedback disabled. This new methodology was used to assess the backscatter characteristics of asymmetric over-traveling jaws. Excellent agreement between the backscatter values measured using the new methodology introduced here and the ones obtained using the other two methods was established. The experimental values reported here differ by less than 1 % from published data. The sensitivity of this novel technique allowed differences in backscatter due to the same opening of the jaws, when placed at different positions on the beam path, to be resolved. The introduction of the ecliptic method has made the determination of the backscatter to the monitor chambers an easy procedure. The method presented here for machines equipped with MLCs makes the determination of backscatter to the beam monitor chambers even easier, and suitable to characterize linacs equipped with over-traveling asymmetric secondary collimators. This experimental procedure could be simply implemented to fully characterize the backscatter output factor constituent when detailed dosimetric modeling of the machine’s head is required. The methodology proved to be uncomplicated, accurate and suitable for clinical or experimental environments.

  11. "Same Room, Safe Place".

    Science.gov (United States)

    Keene Woods, Nikki

    2017-04-01

    There are many different professional stances on safe sleep and then there is the reality of caring for a newborn. There is a debate among professionals regarding safe sleep recommendations. The continum of recommendations vary from the American Academy of Pediatrics (AAP) Safe Sleep Guidelines to the bed-sharing recommendations from the Mother-Baby Behavioral Sleep Laboratory. The lack of consistent and uniform safe sleep recommendations from health professionals has been confusing for families but has more recently raised a real professional ethical dilemma. Despite years of focused safe sleep community education and interventions, sleep-related infant deaths are on the rise in many communities. This commentary calls for a united safe sleep message from all health professionals to improve health for mothers and infants most at-risk, "Same Room, Safe Place."

  12. [Hospital emergency rooms].

    Science.gov (United States)

    Tudela, Pere; Mòdol, Josep Maria

    2003-05-17

    Overuse of hospital emergency rooms (HERs) is parallel to their controversy. To understand this problem, some concepts should be first clarified. In HERs, there are some intrinsic aspects which are directly related to the emergency itself and thus cannot be modified (intermittent patient flow, need to prioritize, difficulty to achieve a rapid diagnosis, influence of time on treatment, value of clinical follow up, patient's expectations, impact of HER on the overall hospital working dynamics). On the other hand, there are some extrinsic aspects which indeed are not related to HER itself but are rather historically associated with it (precarious structure, delay on admission, lack of privacy, inadequate triage of cases, lack of professionalization); these latter aspects may be potentially modified and should be reconsidered.

  13. Room to Groove?

    DEFF Research Database (Denmark)

    Seabrooke, Leonard

    . As long as they stay within the parameters of legitimate financial practice to signal institutional isomorphism, the `groove', creditors may well allow borrowers room for change in self-determined ways. This paper maps out the historical and conceptual terrain concerning civilizing ideas about...... the legitimacy of financial practices within global capital markets, and investigates relationships between Western `civilizers' and Emerging Market Economies during the last two periods of financial globalization, the late-nineteenth/ early-twentieth centuries and the late-twentieth century.......The use of a `standard of civilization', a preferred form of socio-political organization, in global capital markets presents both constraints and opportunities for creditors and borrowers. When imposed, civilizing standards may change how a borrower would prefer to conduct their affairs. Creditors...

  14. Binaural room simulation

    Science.gov (United States)

    Lehnert, H.; Blauert, Jens; Pompetzki, W.

    1991-01-01

    In every-day listening the auditory event perceived by a listener is determined not only by the sound signal that a sound emits but also by a variety of environmental parameters. These parameters are the position, orientation and directional characteristics of the sound source, the listener's position and orientation, the geometrical and acoustical properties of surfaces which affect the sound field and the sound propagation properties of the surrounding fluid. A complete set of these parameters can be called an Acoustic Environment. If the auditory event perceived by a listener is manipulated in such a way that the listener is shifted acoustically into a different acoustic environment without moving himself physically, a Virtual Acoustic Environment has been created. Here, we deal with a special technique to set up nearly arbitrary Virtual Acoustic Environments, the Binaural Room Simulation. The purpose of the Binaural Room Simulation is to compute the binaural impulse response related to a virtual acoustic environment taking into account all parameters mentioned above. One possible way to describe a Virtual Acoustic Environment is the concept of the virtual sound sources. Each of the virtual sources emits a certain signal which is correlated but not necessarily identical with the signal emitted by the direct sound source. If source and receiver are non moving, the acoustic environment becomes a linear time-invariant system. Then, the Binaural Impulse Response from the source to a listener' s eardrums contains all relevant auditory information related to the Virtual Acoustic Environment. Listening into the simulated environment can easily be achieved by convolving the Binaural Impulse Response with dry signals and representing the results via headphones.

  15. Cosmic ray acceleration mechanisms

    International Nuclear Information System (INIS)

    Cesarsky, C.J.

    1982-09-01

    We present a brief summary of some of the most popular theories of cosmic ray acceleration: Fermi acceleration, its application to acceleration by shocks in a scattering medium, and impulsive acceleration by relativistic shocks

  16. Design, implementation and evaluation of an independent real-time safety layer for medical robotic systems using a force-torque-acceleration (FTA) sensor.

    Science.gov (United States)

    Richter, Lars; Bruder, Ralf

    2013-05-01

    Most medical robotic systems require direct interaction or contact with the robot. Force-Torque (FT) sensors can easily be mounted to the robot to control the contact pressure. However, evaluation is often done in software, which leads to latencies. To overcome that, we developed an independent safety system, named FTA sensor, which is based on an FT sensor and an accelerometer. An embedded system (ES) runs a real-time monitoring system for continuously checking of the readings. In case of a collision or error, it instantaneously stops the robot via the robot's external emergency stop. We found that the ES implementing the FTA sensor has a maximum latency of [Formula: see text] ms to trigger the robot's emergency stop. For the standard settings in the application of robotized transcranial magnetic stimulation, the robot will stop after at most 4 mm. Therefore, it works as an independent safety layer preventing patient and/or operator from serious harm.

  17. Workshop on the accelerator for particle therapy

    International Nuclear Information System (INIS)

    Inoue, M.; Ujeno, Y.

    1991-02-01

    A two-day workshop on the accelerator for particle therapy was held on August 22-23, 1990, with the aim of mutual understanding of medical accelerators among investigators. The state-of-the-art facilities in Japan and medical proton accelerators in Japan and other countries were introduced. This is a compilation of papers presented at the workshop: (1) particle radiotherapy at the National Institute of Radiological Sciences (NIRS); (2) proton therapy; (3) treatment planning, especially for photon and electron therapies; (4) heavy ion synchrotron project at the NIRS; (5) medical proton accelerator project of Tsukuba University and recent status of Loma Linda University Medical Center Proton Beam Facility; (6) inspection report on the Loma Linda University Medical Center Proton Beam Facility; (7) accelerator project of Kyoto University; (8) actual conditions of the 7 MeV proton linear accelerator; (9) design study of superconducting compact cyclotron prototype model; (10) medical superconducting prototype cyclotron; (11) RCNP cyclotron cascade project; (12) beam extraction from synchrotron; (13) radiation safety design in high energy particle accelerator facilities. (N.K.)

  18. Improvement in Care and Outcomes for Emergency Medical Service-Transported Patients With ST-Elevation Myocardial Infarction (STEMI) With and Without Prehospital Cardiac Arrest: A Mission: Lifeline STEMI Accelerator Study.

    Science.gov (United States)

    Kragholm, Kristian; Lu, Di; Chiswell, Karen; Al-Khalidi, Hussein R; Roettig, Mayme L; Roe, Matthew; Jollis, James; Granger, Christopher B

    2017-10-11

    Patients with ST-elevation myocardial infarction (STEMI) with out-of-hospital cardiac arrest (OHCA) may benefit from direct transport to a percutaneous cardiac intervention (PCI) hospital but have previously been less likely to bypass local non-PCI hospitals to go to a PCI center. We reported time trends in emergency medical service transport and care of patients with STEMI with and without OHCA included from 171 PCI-capable hospitals in 16 US regions with participation in the Mission: Lifeline STEMI Accelerator program between July 1, 2012, and March 31, 2014. Time trends by quarter were assessed using logistic regression with generalized estimating equations to account for hospital clustering. Of 13 189 emergency medical service-transported patients, 88.7% (N=11 703; 10.5% OHCA) were taken directly to PCI hospitals. Among 1486 transfer-in patients, 21.7% had OHCA. Direct transport to a PCI center for OHCA increased from 74.7% (July 1, 2012) to 83.6% (March 31, 2014) (odds ratio per quarter, 1.07; 95% confidence interval, 1.02-1.14), versus 89.0% to 91.0% for patients without OHCA (odds ratio, 1.03; 95% confidence interval, 0.99-1.07; interaction P =0.23). The proportion with prehospital ECGs increased for patients taken directly to PCI centers (53.9%-61.9% for those with OHCA versus 73.9%-81.9% for those without OHCA; interaction P =0.12). Of 997 patients with OHCA taken directly to PCI hospitals and treated with primary PCI, first medical contact-to-device times within the guideline-recommended goal of ≤90 minutes were met for 34.5% on July 1, 2012, versus 41.8% on March 31, 2014 (51.6% and 56.1%, respectively, for 9352 counterparts without OHCA; interaction P =0.72). Direct transport to PCI hospitals increased for patients with STEMI with and without OHCA during the 2012 to 2014 Mission: Lifeline STEMI Accelerator program. Proportions with prehospital ECGs and timely reperfusion increased for patients taken directly to PCI hospitals. © 2017 The Authors

  19. Comments on shielding for dual energy accelerators

    International Nuclear Information System (INIS)

    Rossi, M. C.; Lincoln, H. M.; Quarin, D. J.; Zwicker, R. D.

    2008-01-01

    Determination of shielding requirements for medical linear accelerators has been greatly facilitated by the publication of the National Council on Radiation Protection and Measurements (NCRP) latest guidelines on this subject in NCRP Report No. 151. In the present report the authors review their own recent experience with patient treatments on conventional dual energy linear accelerators to examine the various input parameters needed to follow the NCRP guidelines. Some discussion is included of workloads, occupancy, use factors, and field size, with the effects of intensity modulated radiotherapy (IMRT) treatments included. Studies of collimator settings showed average values of 13.1x16.2 cm 2 for 6 MV and 14.1x16.8 cm 2 for 18 MV conventional ports, and corresponding average unblocked areas of 228 and 254 cm 2 , respectively. With an average of 77% of the field area unblocked, this gives a mean irradiated area of 196 cm 2 for the 18 MV beam, which dominates shielding considerations for most dual energy machines. Assuming conservatively small room dimensions, a gantry bin angle of 18 deg. was found to represent a reasonable unit for tabulation of use factors. For conventional 18 MV treatments it was found that the usual treatment angles of 0, 90, 180, and 270 deg. were still favored, and use factors of 0.25 represent reasonable estimates for these beams. As expected, the IMRT fields (all at 6 MV) showed a high degree of gantry angle randomization, with no bin having a use factor in excess of 0.10. It is concluded that unless a significant number of patients are treated with high energy IMRT, the traditional use factors of 0.25 are appropriate for the dominant high energy beam

  20. Comments on shielding for dual energy accelerators.

    Science.gov (United States)

    Rossi, M C; Lincoln, H M; Quarin, D J; Zwicker, R D

    2008-06-01

    Determination of shielding requirements for medical linear accelerators has been greatly facilitated by the publication of the National Council on Radiation Protection and Measurements (NCRP) latest guidelines on this subject in NCRP Report No. 151. In the present report the authors review their own recent experience with patient treatments on conventional dual energy linear accelerators to examine the various input parameters needed to follow the NCRP guidelines. Some discussion is included of workloads, occupancy, use factors, and field size, with the effects of intensity modulated radiotherapy (IMRT) treatments included. Studies of collimator settings showed average values of 13.1 x 16.2 cm2 for 6 MV and 14.1 x 16.8 cm2 for 18 MV conventional ports, and corresponding average unblocked areas of 228 and 254 cm2, respectively. With an average of 77% of the field area unblocked, this gives a mean irradiated area of 196 cm2 for the 18 MV beam, which dominates shielding considerations for most dual energy machines. Assuming conservatively small room dimensions, a gantry bin angle of 18 degrees was found to represent a reasonable unit for tabulation of use factors. For conventional 18 MV treatments it was found that the usual treatment angles of 0, 90, 180, and 270 degrees were still favored, and use factors of 0.25 represent reasonable estimates for these beams. As expected, the IMRT fields (all at 6 MV) showed a high degree of gantry angle randomization, with no bin having a use factor in excess of 0.10. It is concluded that unless a significant number of patients are treated with high energy IMRT, the traditional use factors of 0.25 are appropriate for the dominant high energy beam.

  1. Progress toward NLC / GLC prototype accelerator structures

    CERN Document Server

    Wang, J W; Arkan, T; Baboi, N; Boffo, C; Bowden, G B; Burke, D L; Carter, H; Chan, J; Cornuelle, J; Döbert, Steffen; Dolgashev, Valery A; Finley, D; Gonin, I; Higashi, Y; Higo, T; Jones, R M; Khabiboulline, T; Kume, T; Lewandowski, J; Li, Z; Miller, R H; Mishra, S; Morozumi, Y; Nantista, C; Pearson, C; Romanov, G; Ruth, Ronald D; Solyak, N; Tantawi, S; Toge, N; Ueno, K; Wilson, P B; Xiao, L

    2004-01-01

    The accelerator structure groups for NLC (Next Linear Collider) and GLC (Global Linear Colliders) have successfully collaborated on the research and development of a major series of advanced accelerator structures based on room-temperature technology at X-band frequency. The progress in design, simulation, microwave measurement and high gradient tests are summarized in this paper. The recent effort in design and fabrication of the accelerator structure prototype for the main linac is presented in detail including HOM (High Order Mode) suppression and couplers, fundamental mode couplers, optimized accelerator cavities as well as plans for future structures. We emphasize techniques to reduce the field on the surface of the copper structures (in order to achieve high accelerating gradients), limit the dipole wakefields (to relax alignment tolerance and prevent a beam break up instability) and improve shunt impedance (to reduce the RF power required).

  2. Comorbidity in Emergency Room: the Psychiatrist’s Perspective

    OpenAIRE

    Alice Luís

    2013-01-01

    The author puts forward some considerations about the psychiatric practice in the emergency room of a general hospital. Clinical practice in the emergency room should be highlighted by collaborative work between several medical subspecialities, in- cluding internal medicine and neurology. This is particularly true for patients with comorbidity in order to provide quality of care. Finally, the author reviews several clinical cases and suggests guidelines for their management.

  3. Accelerator driven neutron sources in Korea. Current and future

    International Nuclear Information System (INIS)

    Lee, Young-Ouk; Oh, Byung-Hoon; Hong, Bong-Geun; Chang, Jonghwa; Chang, Moon-Hee; Kim, Guinyun; Kim, Gi-Donng; Choi, Byung-Ho

    2008-01-01

    The Pohang Neutron Facility, based on a 65 MeV electron linear accelerator, has a neutron-gamma separation circuit, water-moderated tantalum target and 12 m TOF. It produces pulsed photonuclear neutrons with ≅2 μs width, 50 mA peak current and 15 Hz repetition, mainly for the neutron nuclear data production in up to keV energies. The Tandem Van de Graff at Korea Institute of Geoscience and Mineral Resources (KIGAM) is dedicated to measure MeV energy neutron capture and total cross section using TOF and prompt gamma ray detection system. The facility pulsed ≅10 8 mono-energetic neutrons/sec from 3 H(p,n) reaction with 1-2 ns width and 125 ns period. Korea Institute of Radiological and Medical Sciences (KIRAMS) has the MC50 medical cyclotron which accelerates protons up to an energy of 45 MeV and has several beam ports for proton or neutron irradiations. Beam current can be controlled from a few nano amperes to 50 uA. Korea Atomic Energy Research Institute (KAERI) has a plan to develop a neutron source by using 20 MeV electron accelerator. This photo-neutron source will be mainly used for nuclear data measurements based on time-of-flight experiments. A high intensity fast neutron source is also proposed to respond growing demands of fast neutrons, especially for the fusion material test. Throughput will be as high as several 10 13 neutrons/sec from D-T reaction powered by a high current (200 mA) ion source, a drive-in target and cooling systems, and closed circuit tritium ventilation/recovery systems. The Proton Engineering Frontier Project (PEFP) is developing a 100 MeV, 20 mA pulsed proton linear accelerator equipped with 5 target rooms, one of which is dedicated to produce neutrons using tungsten target. PEFP also proposes the 1-2 GeV rapid cycling synchrotron accelerator as an extension of the PEFP linac, which can be used for nuclear and high energy physics experiment, spallation neutron source, radioisotope, medical research, etc. (author)

  4. Control console of the gamma calibration room

    International Nuclear Information System (INIS)

    Vilchis P, A.E.; Romero G, M.

    1999-01-01

    The Nuclear Centre of Mexico has a Ionizing Radiation Metrology Center (CMRI). This is in charge of the calibration in Mexico and Latin America of equipment dedicated to radiation measurement as industrial, medical as other fields. The importance to ensure that the equipment stay justly calibrated, it is imposed the necessity of automating the different rooms which the CMRI has. in this case it will be exposed the Calibration room for gamma radiation type. The operation of this application was carried out with the LabVIEW development platform and also in C language. The hardware associated is: personal computer with two cards using the 8255 device, 16 channels with optical isolation to manage input/output TTL type, 16 channels with optical isolation to management of charges to 127 V a.c., and 2 channels for 90V d.c. motors. (Author)

  5. Leadership in the control room

    International Nuclear Information System (INIS)

    McDougall, S.J.

    2006-01-01

    This paper discusses the importance of leadership within the control rooms at nuclear power facilities. the leadership capability of control room staff has a significant influence over the improvement of human performance and the development of an 'event free' culture within the business. The development of leadership competency in the control room must be an important part of any nuclear power utility business improvement plan. (author)

  6. Leadership in the control room

    Energy Technology Data Exchange (ETDEWEB)

    McDougall, S.J. [Bruce Power, Bruce B Operations Div., Tiverton, Ontario (Canada)

    2006-07-01

    This paper discusses the importance of leadership within the control rooms at nuclear power facilities. the leadership capability of control room staff has a significant influence over the improvement of human performance and the development of an 'event free' culture within the business. The development of leadership competency in the control room must be an important part of any nuclear power utility business improvement plan. (author)

  7. Procedure to measure the neutrons spectrum around a lineal accelerator for radiotherapy

    International Nuclear Information System (INIS)

    Vega C, H. R.; Hernandez D, V. M.; Letechipia de L, C.; Benites R, J. L.; Salas L, M. A.

    2013-10-01

    An experimental procedure was developed, by means of Bonner spheres, to measure the neutrons spectrum around Linacs of medical use that only requires of a single shot of the accelerator; to this procedure we denominate Planetary or Isocentric method. One of the problems associated to the neutrons spectrum measurement in a radiotherapy room with lineal accelerator is because inside the room a mixed, intense and pulsed radiation field takes place affecting the detection systems based on active detector; this situation is solved using a passive detector. In the case of the Bonner spheres spectrometer the active detector has been substituted by activation detectors, trace detectors or thermoluminescent dosimeters. This spectrometer uses several spheres that are situated one at a time in the measurement point, this way to have the complete measurements group the accelerator should be operated, under the same conditions, so many times like spheres have the spectrometer, this activity can consume a long time and in occasions due to the work load of Linac to complicate the measurement process too. The procedure developed in this work consisted on to situate all the spectrometer spheres at the same time and to make the reading by means of a single shot, to be able to apply this procedure, is necessary that before the measurements two characteristics are evaluated: the cross-talking of the spheres and the symmetry conditions of the neutron field. This method has been applied to determine the photo-neutrons spectrum produced by a lineal accelerator of medical use Varian ix of 15 MV to 100 cm of the isocenter located to 5 cm of depth of a solid water mannequin of 30 x 30 x 15 cm. The spectrum was used to determine the total flow and the environmental dose equivalent. (Author)

  8. Application of electron accelerator worldwide

    International Nuclear Information System (INIS)

    Machi, Sueo

    2003-01-01

    Electron accelerator is an important radiation source for radiation technology, which covers broad fields such as industry, health care, food and environmental protection. There are about 1,000 electron accelerators for radiation processing worldwide. Electron accelerator has advantage over Co-60 irradiator in term of high dose rate and power, assurance of safety, and higher economic performance at larger volume of irradiation. Accelerator generating higher energy in the range of 10 MeV and high power electron beam is now commercially available. There is a trend to use high-energy electron accelerator replacing Co-60 in case of large through-put of medical products. Irradiated foods, in particular species, are on the commercial market in 35 countries. Electron accelerator is used efficiently and economically for production of new or modified polymeric materials through radiation-induced cross-linking, grafting and polymerization reaction. Another important application of electron beam is the curing of surface coatings in the manufacture of products. Electron accelerators of large capacity are used for cleaning exhaust gases in industrial scale. Economic feasibility studies of this electron beam process have shown that this technology is more cost effective than the conventional process. It should be noted that the conventional limestone process produce gypsum as a by-product, which cannot be used in some countries. By contrast, the by-product of the electron beam process is a valuable fertilizer. (Y. Tanaka)

  9. Application of electron accelerator worldwide

    Energy Technology Data Exchange (ETDEWEB)

    Machi, Sueo [Japan Atomic Industrial Forum, Inc., Tokyo (Japan)

    2003-02-01

    Electron accelerator is an important radiation source for radiation technology, which covers broad fields such as industry, health care, food and environmental protection. There are about 1,000 electron accelerators for radiation processing worldwide. Electron accelerator has advantage over Co-60 irradiator in term of high dose rate and power, assurance of safety, and higher economic performance at larger volume of irradiation. Accelerator generating higher energy in the range of 10 MeV and high power electron beam is now commercially available. There is a trend to use high-energy electron accelerator replacing Co-60 in case of large through-put of medical products. Irradiated foods, in particular species, are on the commercial market in 35 countries. Electron accelerator is used efficiently and economically for production of new or modified polymeric materials through radiation-induced cross-linking, grafting and polymerization reaction. Another important application of electron beam is the curing of surface coatings in the manufacture of products. Electron accelerators of large capacity are used for cleaning exhaust gases in industrial scale. Economic feasibility studies of this electron beam process have shown that this technology is more cost effective than the conventional process. It should be noted that the conventional limestone process produce gypsum as a by-product, which cannot be used in some countries. By contrast, the by-product of the electron beam process is a valuable fertilizer. (Y. Tanaka)

  10. Status report of pelletron accelerator and ECR based heavy ion accelerator programme

    International Nuclear Information System (INIS)

    Gupta, A.K.

    2015-01-01

    The BARC-TIFR Pelletron Accelerator is completing twenty seven years of round-the-clock operation, serving diverse users from institutions within and outside DAE. Over the years, various developmental activities and application oriented programs have been initiated at Pelletron Accelerator Facility, resulting into enhanced utilization of the accelerator. We have also been pursuing an ECR based heavy ion accelerator programme under XII th Plan, consisting of an 18 GHz superconducting ECR (Electron Cyclotron Resonance) ion source and a room temperature RFQ (Radio Frequency Quadrupole) followed by low and high beta superconducting niobium resonator cavities. This talk will provide the current status of Pelletron Accelerator and the progress made towards the ECR based heavy ion accelerator program at BARC. (author)

  11. The transfer of accelerator technology to industry

    International Nuclear Information System (INIS)

    Favale, A.

    1992-01-01

    The national laboratories and universities are sources for innovative accelerator technology developments. With the growing application of accelerators in such fields as semiconductor manufacturing, medical therapy isotope production, nuclear waste transmutation, materials testing, bomb detection, pure science, etc., it is becoming more important to transfer these technologies and build an accelerator industrial base. In this talk the methods of technology transfer, the issues involved in working with the labs and examples of successful technology transfers are discussed. (Author)

  12. Modern control room for AHWR

    International Nuclear Information System (INIS)

    Verghese, Clement C.; Joseph, Jose; Biswas, B.B.; Patil, R.K.

    2005-01-01

    Advanced Heavy Water Reactor (AHWR) is a next generation nuclear power plant being developed by Bhabha Atomic Research Centre. A modern control room has been conceived for operation and monitoring of the plant in tune with the advanced features of the reactor. A state of the art C and I architecture based on extensive use of computers and networking has been conceived for this plant. This architecture enables the implementation of a fully computerised operator friendly control room with soft HMIs. Features of the modern control room and control room and concept of soft HMI based operator interfaces have been described in the paper. (author)

  13. The tandem betatron accelerator

    International Nuclear Information System (INIS)

    Keinigs, R.

    1991-01-01

    This paper reports that the tandem betatron is a compact, high-current induction accelerator that has the capability to accelerate electrons to an energy of order one gigavolt. Based upon the operating principle of a conventional betatron, the tandem betatron employs two synchronized induction cores operating 180 degrees out of phase. Embedded within the cores are the vacuum chambers, and these are connected by linear transport sections to allow for moving the beam back and forth between the two betatrons. The 180 degree phase shift between the core fluxes permits the circumvention of the flux swing constraint that limits the maximum energy gain of a conventional betatron. By transporting the beam between the synchronized cores, an electron can access more than one acceleration cycle, and thereby continue to gain energy. This added degree of freedom also permits a significant decrease in the size of the magnet system. Biasing coils provide independent control of the confining magnetic field. Provided that efficient beam switching can be performed, it appears feasible that a one gigavolt electron beam can be generated and confined. At this energy, a high current electron beam circulating in a one meter radius orbit could provide a very intense source of short wavelength (λ < 10 nm) synchrotron radiation. This has direct application to the emerging field of x-ray lithography. At more modest energies (10 MeV-30 MEV) a compact tandem betatron could be employed in the fields of medical radiation therapy, industrial radiography, and materials processing

  14. Radiation Protection Elephants in the Room

    International Nuclear Information System (INIS)

    Vetter, R. J.

    2004-01-01

    As our system of radiological protection evolves, several significant issues loom within radiation protection discussions and publications. These issues influence the nature of epidemiological and radiobiological research and the establishment of radiation protection recommendations, standards, and regulations. These issues are like the proverbial e lephants in the room . They are large, and it is unwise to ignore them. This paper discusses the impact of three young elephants as they make their presence increasingly obvious: increased cancer susceptibility from early-life exposure to radiation, terrorism and fear of radiation, and patient safety. Increased cancer susceptibility from early-life exposure to radiation is emerging as a discussion topic related to the safety of computed tomography (CT) and other medical modalities. Shortly after publication of CT dose data, manufacturers were helping to reduce doses to children by increasing flexibility for adjustment of technique factors. Also, radiation epidemiological data are being used in the development of guidance on exposure to chemical carcinogens during early life. Re-emergence of public fear of radiation has been fueled by threats of radiological dispersion devises and confusing messages about personal decontamination, emergency room acceptance or rejection of contaminated victims, and environmental clean-up. Finally, several professional publications have characterized risk of medical radiation exposure in terms of patient deaths even though epidemiological data do not support such conclusions. All three of these elephants require excellent science and sophisticated data analysis to coax them from the room. Anecdotal communications that confuse the public should be avoided. These are not the only elephants in the room, but these three are making their presence increasingly obvious. This paper discusses the need for radiation protection professionals to rely on good science in the evolution of the system of

  15. Accelerated ion beam research at ATOMKI

    International Nuclear Information System (INIS)

    Kiss, A.Z.

    2009-01-01

    The paper summarizes the studies on accelerated ion beams at ATOMKI and their technical background, their use from chemical analysis to biological, medical, geological, archaeological applications, their advance from material science to micromachining. (TRA)

  16. From accelerators to storage rings to

    International Nuclear Information System (INIS)

    Panofsky, W.K.H.

    1983-02-01

    This talk gives a general but highly subjective overview of the expectation for accelerators and colliders for high energy physics, but not extended developments of accelerators and storage rings for application to nuclear structure physics, synchrotron radiation, medical applications or industrial use

  17. More room for ISOLDE

    CERN Multimedia

    2005-01-01

    To meet the needs of the new ISOLDE experiments, a new extension has been added to the facility's Building 170. The new extension to Building 170. Moving around the ISOLDE hall was almost like an obstacle course until now. The facility's Building 170 simply didn't have an inch to spare and the ISOLDE team's need to set up new experiments, whose installation could have created difficulties from the safety point of view, only exacerbated the problem. "We had ambitious plans to develop new experiments but no room for them", says Mats Lindroos, ISOLDE's technical coordinator. The only solution was to extend the existing building". This was how a new building saw the light of day. Measuring 24 metres long, 20 metres wide and 12 metres high, it is an extension to the existing Building 170 and should be ready for use this year. The new structure makes use of the existing infrastructure, with part of the end wall of Building 170 being kept as a support for steel platforms. The top of this wall had to be cut away ...

  18. The investigation of the design of hybrid operating room

    International Nuclear Information System (INIS)

    Jiang Weihao; Li Jun

    2011-01-01

    Objective: To investigate the design of the interventional operating room that can meet the needs of modern DSA operation, and the overall arrangement of the hybrid operating room should be reasonable, practical and perspective. Methods: The experience and understanding obtained from the designing and planning of the new Building of Radiology and Surgery in authors' hospital were summarized. In order to meet the requirements of aseptic surgical practices and a full-featured hybrid operating room the following factors should be carefully and synthetically taken into account: the room size, the functional sub-areas, the operational procedures, the aseptic specification, etc. Results: The sufficient verification and scientific design were the important link for building a hybrid operating room. It could provide the surgeons and interventional physicians with more alternative operating methods and it could represent the development trend of medical technology. Conclusion: When planning and designing a new DSA operating room, various factors related to the interventional procedures, such as the room size, the functional sub-areas, the operational procedures and the aseptic specification, should be carefully and synthetically taken into account. The standard of aseptic procedure must be strictly complied with and the various functional sub-areas need to be rationally distributed. The design of hybrid operating room, which joins the functions of both open surgery and interventional management together, should be scientific, practical and perspective. (authors)

  19. Disbursement of $65 million to the State of Texas for construction of a Regional Medical Technology Center at the former Superconducting Super Collider Site, Waxahachie, Texas

    International Nuclear Information System (INIS)

    1995-05-01

    As part of a settlement agreement between the US DOE and the State of Texas, DOE proposes to transfer $65 million of federal funds to the Texas National Research Laboratory Commission (TNLRC) for construction of the Regional Medical Technology Center (RMTC) to be located in Ellis County, Texas. The RMTC would be a state-of-the-art medical facility for proton cancer therapy, operated by the State of Texas in conjunction with the University of Texas Southwestern Medical Center. The RMTC would use the linear accelerator assets of the recently terminated DOE Superconducting Super Collider Project to accelerate protons to high energies for the treatment of cancer patients. The current design provides for treatment areas, examination rooms, support laboratories, diagnostic imaging equipment, and office space as well as the accelerators (linac and synchrotron) and beam steering and shaping components. The potential environmental consequences of the proposed action are expected to be minor

  20. Madness in Sartre's "The Room"

    NARCIS (Netherlands)

    Jongeneel, E.C.S.

    2009-01-01

    In "The Room," part of his short story collection, The Wall (1938), Jean-Paul Sartre investigates madness as an alternative way of bourgeois life and thus takes a stand in the contemporary debate on the existential status of mental illness. "The Room" is a case-study of a "limit situation," as well

  1. A control room lighting study

    International Nuclear Information System (INIS)

    Vaidya, V.V.; Iwasa-Madge, K.M.; Howard, B.; Willson, R.B.

    1984-01-01

    Operators at a Heavy Water Plant in Ontario, Canada complained about lighting-related difficulties in the control room. The Human Factors Engineering Unit was requested to perform a lighting survey and make recommendations to improve the control centre lighting conditions. This paper describes the control room, the operator tasks, the procedures used for the lighting survey, the findings, and the changes recommended

  2. Fire protection for clean rooms

    International Nuclear Information System (INIS)

    Kirson, D.

    1990-01-01

    The fire protection engineer often must decide what size fire can be tolerated before automatic fire suppression systems actuate. Is it a wastepaper basket fire, a bushel basket fire...? In the case of state-of-the-art clean rooms, the answer clearly is not even an incipient fire. Minor fires in clean rooms can cause major losses. This paper discusses what a clean room is and gives a brief overview of the unique fire protection challenges encountered. The two major causes of fire related to clean rooms in the semiconductor industry are flammable/pyrophoric gas fires in plastic ducts and polypropylene wet bench fires. This paper concentrates on plastic ductwork in clean rooms, sprinkler protection in ductwork, and protection for wet benches

  3. VEDs for charged particle accelerators: Indian scenario

    International Nuclear Information System (INIS)

    Bhandari, R.K.

    2012-01-01

    In the initial times after their invention, the charged particle accelerators have, primarily, been used for fundamental studies on nuclei and atoms. From the first modern accelerator, the cathode ray tube, used by J.J. Thomson for the discovery of electron, very recently the gigantic 27 km circumference Large Hadron Collider (LHC) is operational in the search of Higg's boson and related physics issues. Particle accelerators have emerged as powerful microscopes for investigating the finest details of cells, genes, molecules, atoms, protons, neutrons, muons, electrons, quarks and, possibly, still undiscovered even more fundamental constituents of the universe, such as dark matter and dark energy. Several noble prize winning discoveries have been made using accelerators. Accelerators are now being used in a wide area of industrial and medical applications. They are used for the production of radioisotopes for medical imaging, cancer therapy, food sterilization, treatment of waste water, sterilization of medical equipment, material modification, mass spectroscopy, cargo scanning, fabrication of semiconductors etc. Ongoing effort towards the development of accelerators with megawatt beam power is showing hope for a cleaner source of nuclear energy and treatment of nuclear waste. Several tens of thousands of accelerators are presently operational in the world for basic research and applications. Development of new accelerators has several times been driven by new technologies and materials and sometimes they have driven the technological developments towards cutting edge. Some examples are ultra-high vacuum in large volumes, superfluid helium in cryogenics, cryocoolers, superconducting magnets and RF cavities, high power vacuum electronic devices, global control systems, superfast computing and communication networks, giant data storage/processing systems etc. India has been pursuing a fairly robust programme of accelerator development at various institutions. It

  4. Radiation doses inside industrial irradiation installation with linear electron accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Alexandre R., E-mail: alexandre.lima@cnen.gov.br [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Pelegrineli, Samuel Q.; Alo, Gabriel F., E-mail: samuelfisica@yahoo.com.br, E-mail: gabriel.alo@aceletron.com.br [Aceletron Irradiacao Industrial, Aceletrica Comercio e Representacoes Ltda, Rio de Janeiro, RJ (Brazil); Silva, Francisco C.A. Da, E-mail: dasilva@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Aceletron Industrial Irradiation Company is the unique installation in South America to provide industrial irradiation service using two linear electron accelerators of 18 kW and 10 MeV energy. The electron beam technology allows using electrons to irradiate many goods and materials, such as hospital and medical equipment, cosmetics, herbal products, polymers, peat, gemstones and food. Aceletron Company uses a concrete bunker with 3.66 m of thickness to provide the necessary occupational and environmental radiation protection of X-rays produced. The bunker is divided in main four areas: irradiation room, maze, tower and pit. Inside the irradiation room the x-rays radiation rates are measured in two ways: direct beam and 90 deg C. The rates produced in the conveyor system using 10 MeV energy are 500 Gy/min/mA and 15 Gy/min/mA, respectively. For a 1.8 mA current, the rates produced are 900 Gy/min and 27 Gy/min, respectively. Outside the bunker the radiation rate is at background level, but in the tower door and modulation room the radiation rate is 10 μSv/h. In 2014, during a routine operation, an effective dose of 30.90 mSv was recorded in a monthly individual dosimeter. After the investigation, it was concluded that the dose was only in the dosimeter because it felt inside the irradiation room. As Aceletron Company follows the principles of safety culture, it was decided to perform the radiation isodose curves, inside the four areas of the installation, to know exactly the hotspots positions, exposure times and radiation doses. Five hotspots were chosen taking into account worker's routes and possible operational places. The first experiment was done using a package with three TLD and OSLD dosimeters to obtain better statistical results. The first results for the five hotspots near the accelerator machine showed that the radiation dose rates were between 26 Gy/h and 31 Gy/h. The final measurements were performed using a package with one TLD and one OSLD

  5. Radiation doses inside industrial irradiation installation with linear electron accelerator

    International Nuclear Information System (INIS)

    Lima, Alexandre R.; Pelegrineli, Samuel Q.; Alo, Gabriel F.; Silva, Francisco C.A. Da

    2015-01-01

    Aceletron Industrial Irradiation Company is the unique installation in South America to provide industrial irradiation service using two linear electron accelerators of 18 kW and 10 MeV energy. The electron beam technology allows using electrons to irradiate many goods and materials, such as hospital and medical equipment, cosmetics, herbal products, polymers, peat, gemstones and food. Aceletron Company uses a concrete bunker with 3.66 m of thickness to provide the necessary occupational and environmental radiation protection of X-rays produced. The bunker is divided in main four areas: irradiation room, maze, tower and pit. Inside the irradiation room the x-rays radiation rates are measured in two ways: direct beam and 90 deg C. The rates produced in the conveyor system using 10 MeV energy are 500 Gy/min/mA and 15 Gy/min/mA, respectively. For a 1.8 mA current, the rates produced are 900 Gy/min and 27 Gy/min, respectively. Outside the bunker the radiation rate is at background level, but in the tower door and modulation room the radiation rate is 10 μSv/h. In 2014, during a routine operation, an effective dose of 30.90 mSv was recorded in a monthly individual dosimeter. After the investigation, it was concluded that the dose was only in the dosimeter because it felt inside the irradiation room. As Aceletron Company follows the principles of safety culture, it was decided to perform the radiation isodose curves, inside the four areas of the installation, to know exactly the hotspots positions, exposure times and radiation doses. Five hotspots were chosen taking into account worker's routes and possible operational places. The first experiment was done using a package with three TLD and OSLD dosimeters to obtain better statistical results. The first results for the five hotspots near the accelerator machine showed that the radiation dose rates were between 26 Gy/h and 31 Gy/h. The final measurements were performed using a package with one TLD and one OSLD

  6. Sector ring accelerator ''RESATRON''

    International Nuclear Information System (INIS)

    Schwabe, E.

    1980-01-01

    Project of sector ring accelerator RESATRON is described. The curiosity of this accelerator is the second cycle of acceleration of the beam after stripping it on the foil. In such an accelerator heavy ions with a different ratio Z to A can be accelerated. (S.B.)

  7. Multiperiodic accelerator structures for linear particle accelerators

    International Nuclear Information System (INIS)

    Tran, D.T.

    1975-01-01

    High efficiency linear accelerator structures, comprised of a succession of cylindrical resonant cavities for acceleration, are described. Coupling annular cavities are located at the periphery, each being coupled to two adjacent cylindrical cavities. (auth)

  8. The Prevessin Control Room during LEP's start up in 1989.

    CERN Multimedia

    1989-01-01

    The Prévessin Control Room saw its first momentous event when the 400 GeV beam for the SPS was commissioned in the presence of Project Leader John Adams. It was also here that the first proton-antiproton collisions were observed, in 1981. Eight years later, in 1989, operators and directors alike jumped for joy at the announcement of the first electron-positron collisions at the start up of LEP, the biggest accelerator in the world.

  9. Deuteron and neutron induced activation in the Eveda accelerator materials: implications for the accelerator maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, M.; Sanz, J.; Garcia, N.; Cabellos, O. [Madrid Univ. Politecnica, C/ Jose Gutierrez Abascal, lnstituto de Fusion Nuclear (Spain); Sauvan, R. [Universidad Nacional de Educacion a Distancia (UNED), Madrid (Spain); Moreno, C.; Sedano, L.A. [CIEMAT-Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, Association Euratom-CIEMAT, Madrid (Spain)

    2007-07-01

    Full text of publication follows: The IFMIF (International Fusion Materials Irradiation Facility) is an accelerator-based DLi neutron source designed to test fusion reactor candidate materials for high fluence neutrons. Before deciding IFMIF construction, an engineering design and associated experimental data acquisition, defined as EVEDA, has been proposed. Along the EVEDA accelerator, deuteron beam losses collide with the accelerator materials, producing activation and consequent radiations responsible of dose. Calculation of the dose rates in the EVEDA accelerator room is necessary in order to analyze the feasibility for manual maintenance. Dose rates due to the activation produced by the deuteron beam losses interaction with the accelerator materials, will be calculated with the ACAB activation code, using EAF2007 library for deuteron activation cross-sections. Also, dose rates from the activation induced by the neutron source produced by the interaction of deuteron beam losses with the accelerator materials and the deuterium implanted in the structural lattice, will be calculated with the SRIM2006, TMAP7, DROSG2000/NEUYIE, MCNPX and ACAB codes. All calculations will be done for the EVEDA accelerator with the room temperature DTL structure, which is based on copper cavities for the DTL. Some calculations will be done for the superconducting DTL structure, based on niobium cavities for the DTL working at cryogenic temperature. Final analysis will show the dominant mechanisms and major radionuclides contributing to the surface dose rates. (authors)

  10. In the LEAR control room

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    View into the control room of the Low Energy Antiproton Ring (LEAR). Edgar Asseo (sitting) and Dieter Möhl and Georges Carron reflecting upon some beam dynamics (or hardware?) problem. Vassilis Agoritsas, in the background, leaning over a plan or a keyboard. LEAR in its early years (1982 to about 1990) was run from this local control room in building 363 close to the end of the PS South Hall, where the ring was installed. Later-on the operation was surveyed from the PS main control room.

  11. Accelerators of atomic particles

    International Nuclear Information System (INIS)

    Sarancev, V.

    1975-01-01

    A brief survey is presented of accelerators and methods of accelerating elementary particles. The principle of collective accelerating of elementary particles is clarified and the problems are discussed of its realization. (B.S.)

  12. Calculation of the neutrons shielding in cyclotron accelerator

    International Nuclear Information System (INIS)

    Ribeiro, Martha S.; Sanches, Matias P.; Rodrigues, Demerval L.

    2000-01-01

    The objective of radioprotection in cyclotron facilities is to reduce the dose levels in the workplaces to classify them like supervised areas. In this way, the radiation dose rates in areas occupied by workers during cyclotron operations should not exceed 7,5 μSv/h. In controlled areas these levels are not observed and some rigorous controls must be exerted by administrative procedures or protection mechanisms. The Cyclotron Laboratory at IPEN-CNEN/SP has a cyclotron model Cyclone 30, 30 MeV, used for research and it is also used for radioisotopes production for medical diagnosis and therapeutical applications. Among them, 123 I, 67 Ga and 18 F can be pointed. When accelerator is operating, failures in perforations and paths that conduce to room accelerator can be occur and thus, the dose levels are higher than that established by law. For this reason, a review for shielding structure was necessary in order to optimize radiation dose. The purpose of this work was to determine the shielding thickness and adequate material to diminish the dose rates in workplaces to a value below 7,5 μSv/h. It was used a method to employ the equivalent dose value in the facility areas for neutrons fluency rate for the principal reactions in target irradiation processes. The purposed shielding for the vault doors ensures dose levels lower than established limits to supervised areas. (author)

  13. Evaluation of the shielding of a room for radiodiagnostic

    International Nuclear Information System (INIS)

    Padilla R, Z. P.; Acuna D, E.; Escareno J, E.; Vega C, H. R.

    2011-10-01

    The X-ray discovery by Roentgen in 1895 and its application in diagnosis was a breakthrough in medicine. Worldwide, X-ray technique is one of the most widely used procedures in medical diagnosis. At the Mental Health Hospital of Calera Zacatecas a room has been designed as radiology room, however there is not a record of shielding characteristics. In order to determine the features of X-ray equipment that the room can host, in this work a series of calculations were carried out. Calculations were based upon the NCRP 151 recommendations and fulfilling the requirements given in the Mexican standard NOM-229-SSA1-2002. From the actual room conditions this can host a X-ray equipment without fluoroscopy, with a workload of 80 ma-min/week, with 125 k Vp as maximum operating voltage. From the actual conditions a set of recommendations, for better protection of radiation workers and public are also given. (Author)

  14. Control room philosophy: Principles of control room design and control room work

    International Nuclear Information System (INIS)

    Skriver, Jan; Ramberg, Jasmine; Allwin, Pernilla

    2006-01-01

    In order to provide insights for improvement of work in control rooms several factors have to be considered. Knowledge of principles including control room philosophies will guide the recommended improvements. In addition to knowledge about specific principles an advantage for an organization can be an understanding of similarities and policies used in other high risk industry. The report has been developed on the basis of a document analysis of international standards and other guiding documents. (NUREG 0711, ISO 11064, ISO 6385, IEC 60964). In addition to the document analysis which has strived to compare the documents to see similarities in important principals, experience from working with control room design, modifications and evaluations in other high risk industries has pervaded the report. Important principles have been identified which are recommended to be included in a control room philosophy. Many of these are similar to the principles identified in the international standards. An additional principal which is regarded as important is the utilization of Key Performance Indicators (KPI) which can be used as a measure to target preventative means. Further more it is critical that the control room philosophy is easy to access and comprehend for all users. One of the challenges that remain after having developed a control room philosophy is how to utilize it in the daily work situation. It is vital that the document remains as a living document, guiding the continual improvement of the control room in the various life cycle stages

  15. CDRH FOIA Electronic Reading Room

    Data.gov (United States)

    U.S. Department of Health & Human Services — The CDRH FOIA electronic reading room contains frequently requested information via the Freedom of Information Act from the Center for Devices and Radiological Health.

  16. Compact multi-energy electron linear accelerators

    International Nuclear Information System (INIS)

    Tanabe, E.; Hamm, R.W.

    1985-01-01

    Two distinctly different concepts that have been developed for compact multi-energy, single-section, standing-wave electron linear accelerator structures are presented. These new concepts, which utilize (a) variable nearest neighbor couplings and (b) accelerating field phase switching, provide the capability of continuously varying the electron output energy from the accelerator without degrading the energy spectrum. These techniques also provide the means for continuously varying the energy spectrum while maintaining a given average electron energy, and have been tested successfully with several accelerators of length from 0.1 m to 1.9 m. Theoretical amd experimental results from these accelerators, and demonstrated applications of these techniques to medical and industrial linear accelerator technology will be described. In addition, possible new applications available to research and industry from these techniques are presented. (orig.)

  17. Nuclear reactor control room construction

    International Nuclear Information System (INIS)

    Lamuro, R.C.; Orr, R.

    1993-01-01

    A control room for a nuclear plant is disclosed. In the control room, objects labelled 12, 20, 22, 26, 30 in the drawing are no less than four inches from walls labelled 10.2. A ceiling contains cooling fins that extend downwards toward the floor from metal plates. A concrete slab is poured over the plates. Studs are welded to the plates and are encased in the concrete. 6 figures

  18. Accelerating C++ applications in Medical Physics

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The recent developments in multithreading tools in C++, like OpenMP and TBB, taking advantage of the multicore architecture of the nowadays processors, allowed the creation and improvement of powerful softwares for scientific research. This talk will be focused on the development of such software for simulations, data acquisition and image reconstruction in Positron Emission Tomography, one of the most powerful tools for cancer detection.

  19. SCANPLAN planning system for medical accelerators

    International Nuclear Information System (INIS)

    Ovsyannikov, D.A.; Sergeev, S.L.; Stuchenkov, A.B.; Vorogushin, M.F.; Tikhomirov, A.S.; Shishov, V.A.

    2001-01-01

    The SCANPLAN automatic system for planning and documentation of every treatment of the photon radiotherapy is described. The system is oriented at the operating systems Windows 98, 2000 and is developed with using the Visual Studio 6.0 technology. This system consists of the following components: planning unit, module for preparation of anatomical information, data base and patient catalogs [ru

  20. The conference hybrid control room

    International Nuclear Information System (INIS)

    Gieci, A.; Caucik, J.; Macko, J.

    2008-01-01

    An original concept of a hybrid control room was developed for the Mochovce-3 and Mochovce-4 reactor units which are under construction. The basic idea underlying the concept is that the control room should be a main working place for the operators (reactor operator and turbine operator) and for the shift supervisor, designed as a comprehensive unit desk shaped so that all members of the control room crew are in a face-to-face contact constantly. The main desk consists of three clearly identified areas serving the operators and the unit supervisor as their main working places. A soft control system is installed at the main working places. A separate safety-related working place, designed as a panel with classical instrumentations at the conference hybrid control room, is provided in case of abnormal conditions or emergency situation. Principles of ergonomics and cognitive engineering were taken into account when designing the new conference hybrid control room for the Mochovce-3 and -4 reactor units. The sizes, propositions, shapes and disposition of the equipment at the control room have been created and verified by using virtual reality tools. (orig.)