WorldWideScience

Sample records for median operative time

  1. Efficient Scalable Median Filtering Using Histogram-Based Operations.

    Science.gov (United States)

    Green, Oded

    2018-05-01

    Median filtering is a smoothing technique for noise removal in images. While there are various implementations of median filtering for a single-core CPU, there are few implementations for accelerators and multi-core systems. Many parallel implementations of median filtering use a sorting algorithm for rearranging the values within a filtering window and taking the median of the sorted value. While using sorting algorithms allows for simple parallel implementations, the cost of the sorting becomes prohibitive as the filtering windows grow. This makes such algorithms, sequential and parallel alike, inefficient. In this work, we introduce the first software parallel median filtering that is non-sorting-based. The new algorithm uses efficient histogram-based operations. These reduce the computational requirements of the new algorithm while also accessing the image fewer times. We show an implementation of our algorithm for both the CPU and NVIDIA's CUDA supported graphics processing unit (GPU). The new algorithm is compared with several other leading CPU and GPU implementations. The CPU implementation has near perfect linear scaling with a speedup on a quad-core system. The GPU implementation is several orders of magnitude faster than the other GPU implementations for mid-size median filters. For small kernels, and , comparison-based approaches are preferable as fewer operations are required. Lastly, the new algorithm is open-source and can be found in the OpenCV library.

  2. Influence of median surgeon operative duration on adverse outcomes in bariatric surgery.

    Science.gov (United States)

    Reames, Bradley N; Bacal, Daniel; Krell, Robert W; Birkmeyer, John D; Birkmeyer, Nancy J O; Finks, Jonathan F

    2015-01-01

    Evidence suggests that prolonged operative time adversely affects surgical outcomes. However, whether faster surgeons have better outcomes is unclear, as a surgeon׳s speed could reflect skill and efficiency, but may alternatively reflect haste. This study evaluates whether median surgeon operative time is associated with adverse surgical outcomes after laparoscopic Roux-en-Y gastric bypass. We performed a retrospective cohort study using statewide clinical registry data from the years 2006 to 2012. Surgeons were ranked by their median operative time and grouped into terciles. Multivariable logistic regression with robust standard errors was used to evaluate the influence of median surgeon operative time on 30-day surgical outcomes, adjusting for patient and surgeon characteristics, trainee involvement, concurrent procedures, and the complex interaction between these variables. A total of 16,344 patients underwent surgery during the study period. Compared to surgeons in the fastest tercile, slow surgeons required 53 additional minutes to complete a gastric bypass procedure (median [interquartile range] 139 [133-150] versus 86 [69-91], Ppatient characteristic only, slow surgeons had significantly higher adjusted rates of any complication, prolonged length of stay, emergency department visits or readmissions, and venous thromboembolism (VTE). After further adjustment for surgeon characteristics, resident involvement, and the interaction between these variables, slow surgeons had higher rates of any complication (10.5% versus 7.1%, P=.039), prolonged length of stay (14.0% versus 4.4%, P=.002), and VTE (0.39% versus .22%, P<.001). Median surgeon operative duration is independently associated with adjusted rates of certain adverse outcomes after laparoscopic Roux-en-Y gastric bypass. Improving surgeon efficiency while operating may reduce operative time and improve the safety of bariatric surgery. Copyright © 2015 American Society for Bariatric Surgery. Published by

  3. Body Mass Index and Operating Times in Vascular Procedures

    Directory of Open Access Journals (Sweden)

    M. Durup-Dickenson

    Full Text Available : Introduction: The influence of body mass index (BMI on operating times in central and peripheral vascular surgical procedures was investigated. Report: A national cohort of Danish patients who underwent a vascular procedure between 1983 and 2012 was used for analysis. Data were analysed with pairwise comparisons of BMI groups for operating times using the independent samples Kruskall–Wallis test. Discussion: A total of 3,255 carotid endarterectomies; 6,885 central vascular procedures; and 4,488 peripheral bypasses were included for the analysis. Median operating times for carotid endarterectomy and central vascular procedures were, respectively, 5 and 15 minutes longer in obese patients than in normal weight patients. This represents a 7% and 10% increase in median operating times, respectively. Linear and multi-adjusted linear regressions were conducted adjusting for confounders, showing a significant correlation between BMI and operating time. Obesity significantly increased the operating times in carotid endarterectomy and central vascular procedures. These may have ramifications for the individual operative stress but not necessarily on logistical operation planning. Keywords: Body mass index (BMI, Obesity, Operating time, Surgery, Vascular surgical procedures

  4. Large window median filtering on Clip7

    Energy Technology Data Exchange (ETDEWEB)

    Mathews, K N

    1983-07-01

    Median filtering has been found to be a useful operation to perform on images in order to reduce random noise while preserving edges of objects. However, in some cases, as the resolution of the image increases, so too does the required window size of the filter. For parallel array processors, this leads to problems when dealing with the large amount of data involved. That is to say that there tend to be problems over slow access of data from pixels over a large neighbourhood, lack of available storage of this data during the operation and long computational times for finding the median. An algorithm for finding the median, designed for use on byte wide architecture parallel array processors is presented together with its implementation on Clip7, a scanning array of such processors. 6 references.

  5. Median survival time of patients after transcatheter chemo-embolization for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Haider, Z.; Haq, T.; Munir, K.; Usman, M.U.; Azeemuddin, M.

    2006-01-01

    Objective: To determine the effect on survival after trans arterial chemo embolization (TACE) in patients with unresectable hepatocellular carcinoma (HCC). Design: Longitudinal cohort study. Place and Duration of Study: Radiology Department, The Aga Khan University Hospital, Stadium Road, Karachi, from December 1997 to September 2005. Patients and Methods: Patients undergoing TACE procedure for HCC were prospectively followed. Forty three patients were enrolled from December 1997 to March 2003 in the study and subjected to chemo embolization therapy. Eight out of 43 patients were excluded from the study, who lost to follow-up. All the patients were followed till their death. Median and mean survival were calculated. Results: The median survival of these 35 patients was 410 days (13.6 months), with 95% confidence interval (236 days lower bound and 536 days upper bound). Mean survival time was 603 days (20.1 months) with 95% confidence interval (394 days lower bound and 812 days upper bound). There was significant difference in mean survival time (in days) by Child's Pugh class (X2 = 12.384; df=2, p-value=0.002). Conclusion: The study showed that TACE is an effective palliative treatment. TACE increases the median survival time. (author)

  6. Median and Morphological Specialized Processors for a Real-Time Image Data Processing

    Directory of Open Access Journals (Sweden)

    Kazimierz Wiatr

    2002-01-01

    Full Text Available This paper presents the considerations on selecting a multiprocessor MISD architecture for fast implementation of the vision image processing. Using the author′s earlier experience with real-time systems, implementing of specialized hardware processors based on the programmable FPGA systems has been proposed in the pipeline architecture. In particular, the following processors are presented: median filter and morphological processor. The structure of a universal reconfigurable processor developed has been proposed as well. Experimental results are presented as delays on LCA level implementation for median filter, morphological processor, convolution processor, look-up-table processor, logic processor and histogram processor. These times compare with delays in general purpose processor and DSP processor.

  7. Choice reaction time in patients with post-operative cognitive dysfunction

    DEFF Research Database (Denmark)

    Steinmetz, J.; Rasmussen, L.S.

    2008-01-01

    BACKGROUND: Post-operative cognitive dysfunction (POCD) is detected by administration of a neuropsychological test battery. Reaction time testing is at present not included as a standard test. Choice reaction time (CRT) data from the first International Study of Post-operative Cognitive Dysfunction...... in nine countries. CRT was measured 52 times using the four boxes test. Patients performed the test before surgery (n=1083), at 1 week (n=926) and at 3 months (n=852) post-operatively. CRT for the individual patient was determined as the median time of correct responses. The usefulness of the CRT...... had a significantly longer CRT. ROC curves revealed that a reaction time of 813 ms was the most appropriate cut-off at 1 week and 762 ms at 3 months but the positive predictive value for POCD was low: 34.4% and 14.7%, respectively. CONCLUSIONS: Post-operative cognitive dysfunction is associated...

  8. Time Operators and Time Crystals

    OpenAIRE

    Nakatsugawa, K.; Fujii, T.; Saxena, A.; Tanda, S.

    2017-01-01

    We investigate time operators in the context of quantum time crystals in ring systems. We demonstrate that a self-adjoint time operator with a periodic time evolution can be derived for a free particle on a ring system: The conventional Aharonov-Bohm time operator is obtained by taking the infinite-radius limit. We also reveal the relationship between our time operator and a $\\mathcal PT$-symmetric time operator. We find that both time operators indeed describe the periodic time evolution of ...

  9. Median Filtering Methods for Non-volcanic Tremor Detection

    Science.gov (United States)

    Damiao, L. G.; Nadeau, R. M.; Dreger, D. S.; Luna, B.; Zhang, H.

    2016-12-01

    Various properties of median filtering over time and space are used to address challenges posed by the Non-volcanic tremor detection problem. As part of a "Big-Data" effort to characterize the spatial and temporal distribution of ambient tremor throughout the Northern San Andreas Fault system, continuous seismic data from multiple seismic networks with contrasting operational characteristics and distributed over a variety of regions are being used. Automated median filtering methods that are flexible enough to work consistently with these data are required. Tremor is characterized by a low-amplitude, long-duration signal-train whose shape is coherent at multiple stations distributed over a large area. There are no consistent phase arrivals or mechanisms in a given tremor's signal and even the durations and shapes among different tremors vary considerably. A myriad of masquerading noise, anthropogenic and natural-event signals must also be discriminated in order to obtain accurate tremor detections. We present here results of the median methods applied to data from four regions of the San Andreas Fault system in northern California (Geysers Geothermal Field, Napa, Bitterwater and Parkfield) to illustrate the ability of the methods to detect tremor under diverse conditions.

  10. How Predictable Is the Operative Time of Laparoscopic Surgery for Ovarian Endometrioma?

    Directory of Open Access Journals (Sweden)

    Pietro Gambadauro

    2015-01-01

    Full Text Available Endometriosis is a tricky albeit common disease whose management largely relies on laparoscopy. We have studied the operative times of laparoscopic endometrioma surgery in order to assess their predictability and possible predictors. One hundred forty-eight laparoscopies were included, with a median operative time of 70 minutes (mean 75.14; 95% CI: 70.03–80.24. Half of the cases had a duration within 15–20 minutes above or below the median (IQR: 55–93.75, but the whole dataset ranged from 20 to 180 minutes, and the standard deviation was relatively large (31.4. Surgical times were significantly related to technical (number and size of the cysts and nontechnical factors (age, parity, dysmenorrhea, and family history. At multiple logistic regression, after adjusting for number and size of the cysts, surgical times below the first quartile were associated with older age (>30 years old: aOR: 3.590; 95% CI: 1.417–9.091 and parity (≥1 delivery: aOR: 3.409; 95% CI: 1.343–8.651. Longer times, above the third quartile, were instead predicted by a familial anamnesis of endometriosis (aOR: 3.639; 95% CI: 1.246–10.627. Our findings indicate highly variable surgical times, which are predicted by unexpected nontechnical factors. This is consistent with the complexity of endometriosis and its treatment. Productivity and efficiency in endometriosis surgery should focus on the quality of healthcare outcomes rather than on the time spent in the operating theatres.

  11. Robust median estimator in logisitc regression

    Czech Academy of Sciences Publication Activity Database

    Hobza, T.; Pardo, L.; Vajda, Igor

    2008-01-01

    Roč. 138, č. 12 (2008), s. 3822-3840 ISSN 0378-3758 R&D Projects: GA MŠk 1M0572 Grant - others:Instituto Nacional de Estadistica (ES) MPO FI - IM3/136; GA MŠk(CZ) MTM 2006-06872 Institutional research plan: CEZ:AV0Z10750506 Keywords : Logistic regression * Median * Robustness * Consistency and asymptotic normality * Morgenthaler * Bianco and Yohai * Croux and Hasellbroeck Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.679, year: 2008 http://library.utia.cas.cz/separaty/2008/SI/vajda-robust%20median%20estimator%20in%20logistic%20regression.pdf

  12. Quadratic Assignment of Hubs in p-Hub Median Problem

    DEFF Research Database (Denmark)

    Gelareh, Shahin

    We introduce Generalized p-Hub Median Problem (GpHMP) that seeks to locate p hub nodes and install p distinct hub facilities/operators on the hubs while discount factor resulted by consolidation of flow on the hub links depends on the facilities/operators that are installed/operating on both hub...

  13. Characterizing the continuously acquired cardiovascular time series during hemodialysis, using median hybrid filter preprocessing noise reduction.

    Science.gov (United States)

    Wilson, Scott; Bowyer, Andrea; Harrap, Stephen B

    2015-01-01

    The clinical characterization of cardiovascular dynamics during hemodialysis (HD) has important pathophysiological implications in terms of diagnostic, cardiovascular risk assessment, and treatment efficacy perspectives. Currently the diagnosis of significant intradialytic systolic blood pressure (SBP) changes among HD patients is imprecise and opportunistic, reliant upon the presence of hypotensive symptoms in conjunction with coincident but isolated noninvasive brachial cuff blood pressure (NIBP) readings. Considering hemodynamic variables as a time series makes a continuous recording approach more desirable than intermittent measures; however, in the clinical environment, the data signal is susceptible to corruption due to both impulsive and Gaussian-type noise. Signal preprocessing is an attractive solution to this problem. Prospectively collected continuous noninvasive SBP data over the short-break intradialytic period in ten patients was preprocessed using a novel median hybrid filter (MHF) algorithm and compared with 50 time-coincident pairs of intradialytic NIBP measures from routine HD practice. The median hybrid preprocessing technique for continuously acquired cardiovascular data yielded a dynamic regression without significant noise and artifact, suitable for high-level profiling of time-dependent SBP behavior. Signal accuracy is highly comparable with standard NIBP measurement, with the added clinical benefit of dynamic real-time hemodynamic information.

  14. Interfascicular suture with nerve autografts for median, ulnar and radial nerve lesions.

    Science.gov (United States)

    Pluchino, F; Luccarelli, G

    1981-05-01

    Interfascicular nerve suture with autografts is the operation of choice for repairing peripheral nerve injuries because it ensures more precise alignment of the fasciculi and so better chances of reinnervation of the sectioned nerve. The procedure as described by Millesi et al has been used at the Istituto Neurologico di Milano in 30 patients with traumatic lesions of the median, ulnar and radial nerves. All have been followed up for 2 to 7 years since operation. The results obtained are compared with those of other series obtained with interfascicular suture and with epineural suture. Microsurgery is essential. The best time to operate is discussed.

  15. Functional Median Polish

    KAUST Repository

    Sun, Ying

    2012-08-03

    This article proposes functional median polish, an extension of univariate median polish, for one-way and two-way functional analysis of variance (ANOVA). The functional median polish estimates the functional grand effect and functional main factor effects based on functional medians in an additive functional ANOVA model assuming no interaction among factors. A functional rank test is used to assess whether the functional main factor effects are significant. The robustness of the functional median polish is demonstrated by comparing its performance with the traditional functional ANOVA fitted by means under different outlier models in simulation studies. The functional median polish is illustrated on various applications in climate science, including one-way and two-way ANOVA when functional data are either curves or images. Specifically, Canadian temperature data, U. S. precipitation observations and outputs of global and regional climate models are considered, which can facilitate the research on the close link between local climate and the occurrence or severity of some diseases and other threats to human health. © 2012 International Biometric Society.

  16. Median Survival Time of Endometrial Cancer Patients with Lymphovascular Invasion at the Hospital Universiti Sains Malaysia.

    Science.gov (United States)

    Asyikeen, Wan Adnan Wan Nor; Siti-Azrin, Ab Hamid; Jalil, Nur Asyilla Che; Zin, Anani Aila Mat; Othman, Nor Hayati

    2016-11-01

    Endometrial cancer is the most common gynaecologic malignancy among females worldwide. The purpose of this study was to determine the median survival time of endometrial cancer patients at the Hospital Universiti Sains Malaysia (USM). A list of 121 endometrial cancer cases registered at Hospital USM between 2000 until 2011 was retrospectively reviewed. The survival time of the endometrial cancer patients was estimated by Kaplan-Meier survival analysis. Log-rank tests were performed to compare the survival of the patients based on socio-demographics and clinical presentation. Only 108 patients, 87.0%, were included who were of Malay ethnicity. Previous history included menopause in 67.6% of patients and diabetes mellitus in 39.8% of patients; additionally, 63.4% of patients were nulliparous. Tumour staging was as follows: 24.5% stage I, 10.8% stage II, 26.5% stage III and 38.2% stage IV. The overall median survival time of the endometrial cancer patients was 70.20 months (95% confidence interval (CI): 51.79, 88.61). The significant factors were age, the presence of lymphovascular invasion and treatment received. The overall survival of endometrial cancer was low. A prospective study needs to be carried out to discover more effective and accurate tests for the early detection of endometrial cancer.

  17. Characterizing the continuously acquired cardiovascular time series during hemodialysis, using median hybrid filter preprocessing noise reduction

    Directory of Open Access Journals (Sweden)

    Wilson S

    2015-01-01

    Full Text Available Scott Wilson,1,2 Andrea Bowyer,3 Stephen B Harrap4 1Department of Renal Medicine, The Alfred Hospital, 2Baker IDI, Melbourne, 3Department of Anaesthesia, Royal Melbourne Hospital, 4University of Melbourne, Parkville, VIC, Australia Abstract: The clinical characterization of cardiovascular dynamics during hemodialysis (HD has important pathophysiological implications in terms of diagnostic, cardiovascular risk assessment, and treatment efficacy perspectives. Currently the diagnosis of significant intradialytic systolic blood pressure (SBP changes among HD patients is imprecise and opportunistic, reliant upon the presence of hypotensive symptoms in conjunction with coincident but isolated noninvasive brachial cuff blood pressure (NIBP readings. Considering hemodynamic variables as a time series makes a continuous recording approach more desirable than intermittent measures; however, in the clinical environment, the data signal is susceptible to corruption due to both impulsive and Gaussian-type noise. Signal preprocessing is an attractive solution to this problem. Prospectively collected continuous noninvasive SBP data over the short-break intradialytic period in ten patients was preprocessed using a novel median hybrid filter (MHF algorithm and compared with 50 time-coincident pairs of intradialytic NIBP measures from routine HD practice. The median hybrid preprocessing technique for continuously acquired cardiovascular data yielded a dynamic regression without significant noise and artifact, suitable for high-level profiling of time-dependent SBP behavior. Signal accuracy is highly comparable with standard NIBP measurement, with the added clinical benefit of dynamic real-time hemodynamic information. Keywords: continuous monitoring, blood pressure

  18. Allegheny County Median Age at Death

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The median age at death is calculated for each municipality in Allegheny County. Data is based on the decedent's residence at the time of death, not the location...

  19. Median Filter Noise Reduction of Image and Backpropagation Neural Network Model for Cervical Cancer Classification

    Science.gov (United States)

    Wutsqa, D. U.; Marwah, M.

    2017-06-01

    In this paper, we consider spatial operation median filter to reduce the noise in the cervical images yielded by colposcopy tool. The backpropagation neural network (BPNN) model is applied to the colposcopy images to classify cervical cancer. The classification process requires an image extraction by using a gray level co-occurrence matrix (GLCM) method to obtain image features that are used as inputs of BPNN model. The advantage of noise reduction is evaluated by comparing the performances of BPNN models with and without spatial operation median filter. The experimental result shows that the spatial operation median filter can improve the accuracy of the BPNN model for cervical cancer classification.

  20. Median nail dystrophy involving the thumb nail

    Directory of Open Access Journals (Sweden)

    Rahulkrishna Kota

    2016-01-01

    Full Text Available Median canaliform dystrophy of Heller is a rare entity characterized by a midline or a paramedian ridge or split and canal formation in nail plate of one or both the thumb nails. It is an acquired condition resulting from a temporary defect in the matrix that interferes with nail formation. Habitual picking of the nail base may be responsible for some cases. Histopathology classically shows parakeratosis, accumulation of melanin within and between the nail bed keratinocytes. Treatment of median nail dystrophy includes injectable triamcinalone acetonide, topical 0.1% tacrolimus, and tazarotene 0.05%, which is many a times challenging for a dermatologist. Psychiatric opinion should be taken when associated with the depressive, obsessive-compulsive, or impulse-control disorder. We report a case of 19-year-old male diagnosed as median nail dystrophy.

  1. Prevalence and anatomical pattern of the median artery among ...

    African Journals Online (AJOL)

    Knowledge of the anatomy of median arteries is important in the diagnosis and management of carpal tunnel and pronator teres syndromes, reconstructive surgery in the forearm, minimizing inadvertent vascular injury as well as in limiting operative complications due to unexpected bleeding. The anatomical pattern displays ...

  2. Factorizing the time evolution operator

    International Nuclear Information System (INIS)

    Garcia Quijas, P C; Arevalo Aguilar, L M

    2007-01-01

    There is a widespread belief in the quantum physical community, and textbooks used to teach quantum mechanics, that it is a difficult task to apply the time evolution operator e itH-hat/h on an initial wavefunction. Because the Hamiltonian operator is, generally, the sum of two operators, then it is not possible to apply the time evolution operator on an initial wavefunction ψ(x, 0), for it implies using terms like (a-hat + b-hat). A possible solution is to factorize the time evolution operator and then apply successively the individual exponential operator on the initial wavefunction. However, the exponential operator does not directly factorize, i.e. e a-hat+b-hat ≠ e a-hat e b-hat . In this study we present a useful procedure for factorizing the time evolution operator when the argument of the exponential is a sum of two operators, which obey specific commutation relations. Then, we apply the exponential operator as an evolution operator for the case of elementary unidimensional potentials, like a particle subject to a constant force and a harmonic oscillator. Also, we discuss an apparent paradox concerning the time evolution operator and non-spreading wave packets addressed previously in the literature

  3. Sosiaalisen median mahdollisuudet Tilastokeskukselle

    OpenAIRE

    Vesterinen, Anu

    2011-01-01

    Tämän opinnäytetyön aiheena oli sosiaalisen median mahdollisuudet Tilastokeskuksen viestinnässä. Työn tavoitteena oli kartoittaa sosiaalisen median käyttöön liittyviä mahdollisuuksia ja haasteita sekä selvittää siihen liittyviä odotuksia Tilastokeskuksen henkilöstön keskuudessa. Työn teoriaosuudessa tarkasteltiin sosiaalista mediaa käsitteenä ja esiteltiin sosiaalisen median käyttöä organisaation ulkoisen viestinnän välineenä. Opinnäytetyössä selvitettiin teoriatietoon pohjautuen sekä ca...

  4. Evaluation of median nerve T2 signal changes in patients with surgically treated carpal tunnel syndrome.

    Science.gov (United States)

    Samanci, Yavuz; Karagöz, Yeşim; Yaman, Mehmet; Atçı, İbrahim Burak; Emre, Ufuk; Kılıçkesmez, Nuri Özgür; Çelik, Suat Erol

    2016-11-01

    To determine the accuracy of median nerve T2 evaluation and its relation with Boston Questionnaire (BQ) and nerve conduction studies (NCSs) in pre-operative and post-operative carpal tunnel syndrome (CTS) patients in comparison with healthy volunteers. Twenty-three CTS patients and 24 healthy volunteers underwent NCSs, median nerve T2 evaluation and self-administered BQ. Pre-operative and 1st year post-operative median nerve T2 values and cross-sectional areas (CSAs) were compared both within pre-operative and post-operative CTS groups, and with healthy volunteers. The relationship between MRI findings and BQ and NCSs was analyzed. The ROC curve analysis was used for determining the accuracy. The comparison of pre-operative and post-operative T2 values and CSAs revealed statistically significant improvements in the post-operative patient group (pT2 values at all levels and BQ values, and positive and negative correlations were also found regarding T2 values and NCS findings in CTS patients. The receiver operating characteristic curve analysis for defined cut-off levels of median nerve T2 values in hands with severe CTS yielded excellent accuracy at all levels. However, this accuracy could not be demonstrated in hands with mild CTS. This study is the first to analyze T2 values in both pre-operative and post-operative CTS patients. The presence of increased T2 values in CTS patients compared to controls and excellent accuracy in hands with severe CTS indicates T2 signal changes related to CTS pathophysiology and possible utilization of T2 signal evaluation in hands with severe CTS. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Median Sternotomy or Right Thoracotomy Techniques for Total Artificial Heart Implantation in Calves.

    Science.gov (United States)

    Karimov, Jamshid H; Moazami, Nader; Sunagawa, Gengo; Kobayashi, Mariko; Byram, Nicole; Sale, Shiva; Such, Kimberly A; Horvath, David J; Golding, Leonard A R; Fukamachi, Kiyotaka

    2016-10-01

    The choice of optimal operative access technique for mechanical circulatory support device implantation ensures successful postoperative outcomes. In this study, we retrospectively evaluated the median sternotomy and lateral thoracotomy incisions for placement of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) in a bovine model. The CFTAH was implanted in 17 calves (Jersey calves; weight range, 77.0-93.9 kg) through a median sternotomy (n = 9) or right thoracotomy (n = 8) for elective chronic implantation periods of 14, 30, or 90 days. Similar preoperative preparation, surgical techniques, and postoperative care were employed. Implantation of the CFTAH was successfully performed in all cases. Both methods provided excellent surgical field visualization. After device connection, however, the median sternotomy approach provided better visualization of the anastomoses and surgical lines for hemostasis confirmation and repair due to easier device displacement, which is severely limited following right thoracotomy. All four animals sacrificed after completion of the planned durations (up to 90 days) were operated through full median sternotomy. Our data demonstrate that both approaches provide excellent initial field visualization. Full median sternotomy provides larger viewing angles at the anastomotic suture line after device connection to inflow and outflow ports. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  6. Sosiaalisen median markkinointistrategia

    OpenAIRE

    Tran, Jenny

    2017-01-01

    Insinöörityön tavoitteena oli suunnitella toimeksiantajayritykselle sopiva sosiaalisen median markkinointistrategia ja avustaa sen toteutuksessa sekä tuottaen sisältöä sovittuihin kanaviin. Pyrkimyksenä oli myös kouluttaa yrityksen henkilökuntaa käyttämään sosiaalista mediaa yleisellä tasolla ja markkinoinnissa tutustuttamalla heidät sosiaalisen median erilaisiin kanaviin ja mainostyökaluihin. Opinnäytetyössä keskityttiin tutkimaan Facebookissa toimivaa markkinointia ja siinä toimivia mai...

  7. Modeling operators' emergency response time for chemical processing operations.

    Science.gov (United States)

    Murray, Susan L; Harputlu, Emrah; Mentzer, Ray A; Mannan, M Sam

    2014-01-01

    Operators have a crucial role during emergencies at a variety of facilities such as chemical processing plants. When an abnormality occurs in the production process, the operator often has limited time to either take corrective actions or evacuate before the situation becomes deadly. It is crucial that system designers and safety professionals can estimate the time required for a response before procedures and facilities are designed and operations are initiated. There are existing industrial engineering techniques to establish time standards for tasks performed at a normal working pace. However, it is reasonable to expect the time required to take action in emergency situations will be different than working at a normal production pace. It is possible that in an emergency, operators will act faster compared to a normal pace. It would be useful for system designers to be able to establish a time range for operators' response times for emergency situations. This article develops a modeling approach to estimate the time standard range for operators taking corrective actions or following evacuation procedures in emergency situations. This will aid engineers and managers in establishing time requirements for operators in emergency situations. The methodology used for this study combines a well-established industrial engineering technique for determining time requirements (predetermined time standard system) and adjustment coefficients for emergency situations developed by the authors. Numerous videos of workers performing well-established tasks at a maximum pace were studied. As an example, one of the tasks analyzed was pit crew workers changing tires as quickly as they could during a race. The operations in these videos were decomposed into basic, fundamental motions (such as walking, reaching for a tool, and bending over) by studying the videos frame by frame. A comparison analysis was then performed between the emergency pace and the normal working pace operations

  8. Anterolateral minithoracotomy versus median sternotomy for mitral valve disease: a meta-analysis.

    Science.gov (United States)

    Ding, Chao; Jiang, Da-ming; Tao, Kai-yu; Duan, Qun-jun; Li, Jie; Kong, Min-jian; Shen, Zhong-hua; Dong, Ai-qiang

    2014-06-01

    Mitral valve disease tends to be treated with anterolateral minithoracotomy (ALMT) rather than median sternotomy (MS), as ALMT uses progressively smaller incisions to promote better cosmetic outcomes. This meta-analysis quantifies the effects of ALMT on surgical parameters and post-operative outcomes compared with MS. One randomized controlled study and four case-control studies, published in English from January 1996 to January 2013, were identified and evaluated. ALMT showed a significantly longer cardiopulmonary bypass time (P=0.001) and aortic cross-clamp time (P=0.05) compared with MS. However, the benefits of ALMT were evident as demonstrated by a shorter length of hospital stay (PALMT decreased significantly as compared with MS (P=0.05); however, the incidence of peri-operative mortality (P=0.62), re-operation for bleeding (P=0.37), neurologic events (P=0.77), myocardial infarction (P=0.84), gastrointestinal complications (P=0.89), and renal insufficiency (P=0.67) were similar to these of MS. Long-term follow-up data were also examined, and revealed equivalent survival and freedom from mitral valve events. Current clinical data suggest that ALMT is a safe and effective alternative to the conventional approach and is associated with better short-term outcomes and a trend towards longer survival.

  9. Thrombosed persistent median artery causing carpal tunnel syndrome associated with bifurcated median nerve: A case report

    International Nuclear Information System (INIS)

    Salter, M.; Sinha, N. R.; Szmigielski, W.

    2011-01-01

    Background: Carpal tunnel syndrome is a sporadically occurring abnormality due to compression of median nerve. It is exceedingly rare for it to be caused by thrombosis of persistent median artery. Case Report: A forty two year old female was referred for ultrasound examination due to ongoing wrist pain, not relived by pain killers and mild paraesthesia on the radial side of the hand. High resolution ultrasound and Doppler revealed a thrombosed persistent median artery and associated bifurcated median nerve. The thrombus resolved on treatment with anticoagulants. Conclusions: Ultrasound examination of the wrist when done for patients with carpal tunnel syndrome should preferably include looking for persistent median artery and its patency. (authors)

  10. Operative Start Time Does Not Affect Post-Operative Infection Risk.

    Science.gov (United States)

    Guidry, Christopher A; Davies, Stephen W; Willis, Rhett N; Dietch, Zachary C; Shah, Puja M; Sawyer, Robert G

    2016-10-01

    Surgical care is delivered 24 h a day at most institutions. Alarmingly, some authors have found that certain operative start times are associated with greater morbidity and mortality rates. This effect has been noted in both the public and private sector. Although some of these differences may be related to process, they may also be caused by the human circadian rhythm and corresponding changes in host defenses. We hypothesized that the time of day of an operation would impact the frequency of certain post-operative outcomes significantly. Cases at a single tertiary-care center reported to the American College of Surgeons National Surgical Quality Improvement Program over a 10-year period were identified. Operative start times were divided into six-hour blocks, with 6 am to noon serving as the reference. Standard univariable techniques were applied. Multivariable logistic regression with mixed effects modeling then was used to determine the relation between operative start times and infectious outcomes, controlling for surgeon clustering. Statistical significance was set at p operative infectious complication. Seventy percent of these infections (n = 1,506) were surgical site infections. On univariable analysis considering all cases, nighttime and evening operations had higher rates of post-operative infections than those in performed during the day (9.1% from 6 am to noon; 9.7% from noon to 6 pm; 14.8% from 6 pm to midnight; and 14.4% from midnight to 6 am; p operative start time was not associated with the risk of post-operative infection, even when emergency cases were considered independently. Our data suggest that operative start times have no correlation with post-operative infectious complications. Further work is required to identify the source of the time-dependent outcome variability observed in previous studies.

  11. A comparison of freeway median crash frequency, severity, and barrier strike outcomes by median barrier type.

    Science.gov (United States)

    Russo, Brendan J; Savolainen, Peter T

    2018-08-01

    Median-crossover crashes are among the most hazardous events that can occur on freeways, often resulting in severe or fatal injuries. The primary countermeasure to reduce the occurrence of such crashes is the installation of a median barrier. When installation of a median barrier is warranted, transportation agencies are faced with the decision among various alternatives including concrete barriers, beam guardrail, or high-tension cable barriers. Each barrier type differs in terms of its deflection characteristics upon impact, the required installation and maintenance costs, and the roadway characteristics (e.g., median width) where installation would be feasible. This study involved an investigation of barrier performance through an in-depth analysis of crash frequency and severity data from freeway segments where high-tension cable, thrie-beam, and concrete median barriers were installed. A comprehensive manual review of crash reports was conducted to identify crashes in which a vehicle left the roadway and encroached into the median. This review also involved an examination of crash outcomes when a barrier strike occurred, which included vehicle containment, penetration, or re-direction onto the travel lanes. The manual review of crash reports provided critical supplementary information through narratives and diagrams not normally available through standard fields on police crash report forms. Statistical models were estimated to identify factors that affect the frequency, severity, and outcomes of median-related crashes, with particular emphases on differences between segments with varying median barrier types. Several roadway-, traffic-, and environmental-related characteristics were found to affect these metrics, with results varying across the different barrier types. The results of this study provide transportation agencies with important guidance as to the in-service performance of various types of median barrier. Copyright © 2018 Elsevier Ltd. All rights

  12. Sosiaalisen median riskit yritysmaailmassa

    OpenAIRE

    Kilpinen, Joni

    2015-01-01

    Sosiaalisen median palveluista on kirjoitettu lukuisia kirjoja ja artikkeleita, joissa niitä ylistetään varsinkin yritysnäkökulmasta. Vaikka sosiaalinen media on muuttanut olennaisesti tapaa, jolla keskustella, mainostaa, etsiä ja jakaa tietoa, piilee sen palveluiden käytössä kuitenkin erilaisia uhkakuvia. Yritykset ja asiantuntijat pelkäävät sosiaalisen median avoimuuden aiheuttavan suuria tietoturvariskejä. Lisäksi asiantuntijat ovat varoitelleet sosiaalisessa mediassa olevista haittaohjelm...

  13. GPU Accelerated Vector Median Filter

    Science.gov (United States)

    Aras, Rifat; Shen, Yuzhong

    2011-01-01

    Noise reduction is an important step for most image processing tasks. For three channel color images, a widely used technique is vector median filter in which color values of pixels are treated as 3-component vectors. Vector median filters are computationally expensive; for a window size of n x n, each of the n(sup 2) vectors has to be compared with other n(sup 2) - 1 vectors in distances. General purpose computation on graphics processing units (GPUs) is the paradigm of utilizing high-performance many-core GPU architectures for computation tasks that are normally handled by CPUs. In this work. NVIDIA's Compute Unified Device Architecture (CUDA) paradigm is used to accelerate vector median filtering. which has to the best of our knowledge never been done before. The performance of GPU accelerated vector median filter is compared to that of the CPU and MPI-based versions for different image and window sizes, Initial findings of the study showed 100x improvement of performance of vector median filter implementation on GPUs over CPU implementations and further speed-up is expected after more extensive optimizations of the GPU algorithm .

  14. Switching non-local median filter

    Science.gov (United States)

    Matsuoka, Jyohei; Koga, Takanori; Suetake, Noriaki; Uchino, Eiji

    2015-06-01

    This paper describes a novel image filtering method for removal of random-valued impulse noise superimposed on grayscale images. Generally, it is well known that switching-type median filters are effective for impulse noise removal. In this paper, we propose a more sophisticated switching-type impulse noise removal method in terms of detail-preserving performance. Specifically, the noise detector of the proposed method finds out noise-corrupted pixels by focusing attention on the difference between the value of a pixel of interest (POI) and the median of its neighboring pixel values, and on the POI's isolation tendency from the surrounding pixels. Furthermore, the removal of the detected noise is performed by the newly proposed median filter based on non-local processing, which has superior detail-preservation capability compared to the conventional median filter. The effectiveness and the validity of the proposed method are verified by some experiments using natural grayscale images.

  15. Predictive factors in patients with hepatocellular carcinoma receiving sorafenib therapy using time-dependent receiver operating characteristic analysis.

    Science.gov (United States)

    Nishikawa, Hiroki; Nishijima, Norihiro; Enomoto, Hirayuki; Sakamoto, Azusa; Nasu, Akihiro; Komekado, Hideyuki; Nishimura, Takashi; Kita, Ryuichi; Kimura, Toru; Iijima, Hiroko; Nishiguchi, Shuhei; Osaki, Yukio

    2017-01-01

    To investigate variables before sorafenib therapy on the clinical outcomes in hepatocellular carcinoma (HCC) patients receiving sorafenib and to further assess and compare the predictive performance of continuous parameters using time-dependent receiver operating characteristics (ROC) analysis. A total of 225 HCC patients were analyzed. We retrospectively examined factors related to overall survival (OS) and progression free survival (PFS) using univariate and multivariate analyses. Subsequently, we performed time-dependent ROC analysis of continuous parameters which were significant in the multivariate analysis in terms of OS and PFS. Total sum of area under the ROC in all time points (defined as TAAT score) in each case was calculated. Our cohort included 175 male and 50 female patients (median age, 72 years) and included 158 Child-Pugh A and 67 Child-Pugh B patients. The median OS time was 0.68 years, while the median PFS time was 0.24 years. On multivariate analysis, gender, body mass index (BMI), Child-Pugh classification, extrahepatic metastases, tumor burden, aspartate aminotransferase (AST) and alpha-fetoprotein (AFP) were identified as significant predictors of OS and ECOG-performance status, Child-Pugh classification and extrahepatic metastases were identified as significant predictors of PFS. Among three continuous variables (i.e., BMI, AST and AFP), AFP had the highest TAAT score for the entire cohort. In subgroup analyses, AFP had the highest TAAT score except for Child-Pugh B and female among three continuous variables. In continuous variables, AFP could have higher predictive accuracy for survival in HCC patients undergoing sorafenib therapy.

  16. Clinical Outcomes following median to radial nerve transfers

    Science.gov (United States)

    Ray, Wilson Z.; Mackinnon, Susan E.

    2010-01-01

    Purpose In this study the authors evaluate the clinical outcomes in patients with radial nerve palsy who underwent nerve transfers utilizing redundant fascicles of median nerve (innervating the flexor digitorum superficialis and flexor carpi radialis muscles) to the posterior interosseous nerve and the nerve to the extensor carpi radialis brevis. Methods A retrospective review of the clinical records of 19 patients with radial nerve injuries who underwent nerve transfer procedures using the median nerve as a donor nerve were included. All patients were evaluated using the Medical Research Council (MRC) grading system. Results The mean age of patients was 41 years (range 17 – 78 years). All patients received at least 12 months of follow-up (20.3 ± 5.8 months). Surgery was performed at a mean of 5.7 ± 1.9 months post-injury. Post-operative functional evaluation was graded according to the following scale: grades MRC 0/5 - MRC 2/5 were considered poor outcomes, while MRC of 3/5 was a fair result, MRC grade 4/5 was a good result, and grade 4+/5 was considered an excellent outcome. Seventeen patients (89%) had a complete radial nerve palsy while two patients (11%) had intact wrist extension but no finger or thumb extension. Post-operatively all patients except one had good to excellent recovery of wrist extension. Twelve patients recovered good to excellent finger and thumb extension, two patients had fair recovery, five patients had a poor recovery. Conclusions The radial nerve is a commonly injured nerve, causing significant morbidity in affected patients. The median nerve provides a reliable source of donor nerve fascicles for radial nerve reinnervation. This transfer was first performed in 1999 and evolved over the subsequent decade. The important nuances of both surgical technique and motor re-education critical for to the success of this transfer have been identified and are discussed. PMID:21168979

  17. Wound infection after median sternotomy during the war in Croatia.

    Science.gov (United States)

    Jelić, I; Anić, D; Alfirević, I; Kalinić, S; Ugljen, R; Letica, D; Ante Korda, Z; Vucemilo, I; Bulat, C; Predrijevac, M; Corić, V; Husar, J; Jelic, M; Hulina, D; Depina, I; Dadić, D

    1996-12-01

    From 1990 to 1994 at Clinical Hospital Center, Zagreb, 1904 median sternotomies were performed for cardiac operations. Patients shared the same intensive care unit (ICU) with the wounded persons, admitted to the hospital from battlefield. Infection developed in 124 patients, an incidence of 6.51%. Methicillin resistant Staphylococcus aureus (MRSA) was isolated from 90, methicillin resistant Staphylococcus epidermidis (MRSE) from 19, and gram negative bacilli (GNB) from 56 patients, Pseudomonas aeruginosa in 2, and Clostridium pneumoniae in 1 case. Ninety-six patients (5.04%) developed superficial localized infection of subcutaneous tissues and they were treated with frequent dressing changes with antibiotic-soaked gauze in combination with systemic antibiotics. Twenty-eight patients (1.47%) developed mediastinitis and sternal dehiscence. They were treated by operative debridement followed by reclosure of the sternum with continuous antibiotic irrigation. We obtained satisfactory results with our method of closure of sternum which is a modification of Robicsek's technique. Nine of them required further operation. In seven cases we performed muscle flaps and in two omentoplasty. One hundred and twenty patients were discharged in satisfactory condition. The uncontrolled mediastinal sepsis caused death in 4 patients. Higher infection rate after median sternotomy during 1991 and 1992 could be possibly explained with the war circumstances in Croatia, and especially with MRSA strain becoming endemic in surgical ICU.

  18. Functional Median Polish

    KAUST Repository

    Sun, Ying; Genton, Marc G.

    2012-01-01

    polish is demonstrated by comparing its performance with the traditional functional ANOVA fitted by means under different outlier models in simulation studies. The functional median polish is illustrated on various applications in climate science

  19. Five Roots Pattern of Median Nerve Formation

    Directory of Open Access Journals (Sweden)

    Konstantinos Natsis

    2016-04-01

    Full Text Available An unusual combination of median nerve’s variations has been encountered in a male cadaver during routine educational dissection. In particular, the median nerve was formed by five roots; three roots originated from the lateral cord of the brachial plexus joined individually the median nerve’s medial root. The latter (fourth root was united with the lateral (fifth root of the median nerve forming the median nerve distally in the upper arm and not the axilla as usually. In addition, the median nerve was situated medial to the brachial artery. We review comprehensively the relevant variants, their embryologic development and their potential clinical applications.

  20. Radiation dose to the operator during fluoroscopically guided spine procedures

    Energy Technology Data Exchange (ETDEWEB)

    Roccatagliata, Luca; Pravata, Emanuele; Cianfoni, Alessandro [Department of Neuroradiology, Neurocenter of Southern Switzerland, Ospedale Regionale di Lugano, Lugano (Switzerland); Presilla, Stefano [Unita di Fisica Medica, Ente Ospedaliero Cantonale (EOC), Bellinzona (Switzerland)

    2017-09-15

    Fluoroscopy is widely used to guide diagnostic and therapeutic spine procedures. The purpose of this study was to quantify radiation incident on the operator (operator Air Kerma) during a wide range of fluoroscopy-guided spine procedures and its correlation with the amount of radiation incident on the patient (Kerma Area Product - KAP). We retrospectively included 57 consecutive fluoroscopically guided spine procedures. KAP [Gy cm{sup 2}] and total fluoroscopy time were recorded for each procedure. An electronic dosimeter recorded the operator Air Kerma [μGy] for each procedure. Operator Air Kerma for each procedure, correlation between KAP and operator Air Kerma, and between KAP and fluoroscopy time was obtained. Operator Air Kerma was widely variable across procedures, with median value of 6.4 μGy per procedure. Median fluoroscopy time and median KAP per procedure were 2.6 min and 4.7 Gy cm{sup 2}, respectively. There was correlation between operator Air Kerma and KAP (r{sup 2} = 0.60), with a slope of 1.6 μGy Air Kerma per unit Gy cm{sup 2} KAP incident on the patient and between fluoroscopy time and KAP (r{sup 2} = 0.63). Operator Air Kerma during individual fluoroscopy-guided spine procedures can be approximated from the commonly and readily available information of the total amount of radiation incident on the patient, measured as KAP. (orig.)

  1. Median Hetero-Associative Memories Applied to the Categorization of True-Color Patterns

    Science.gov (United States)

    Vázquez, Roberto A.; Sossa, Humberto

    Median associative memories (MED-AMs) are a special type of associative memory based on the median operator. This type of associative model has been applied to the restoration of gray scale images and provides better performance than other models, such as morphological associative memories, when the patterns are altered with mixed noise. Despite of his power, MED-AMs have not been applied in problems involving true-color patterns. In this paper we describe how a median hetero-associative memory (MED-HAM) could be applied in problems that involve true-color patterns. A complete study of the behavior of this associative model in the restoration of true-color images is performed using a benchmark of 14400 images altered by different type of noises. Furthermore, we describe how this model can be applied to an image categorization problem.

  2. Impact of keyboard typing on the morphological changes of the median nerve.

    Science.gov (United States)

    Yeap Loh, Ping; Liang Yeoh, Wen; Nakashima, Hiroki; Muraki, Satoshi

    2017-09-28

    The primary objective was to investigate the effects of continuous typing on median nerve changes at the carpal tunnel region at two different keyboard slopes (0° and 20°). The secondary objective was to investigate the differences in wrist kinematics and the changes in wrist anthropometric measurements when typing at the two different keyboard slopes. Fifteen healthy right-handed young men were recruited. A randomized sequence of the conditions (control, typing I, and typing II) was assigned to each participant. Wrist anthropometric measurements, wrist kinematics data collection and ultrasound examination to the median nerve was performed at designated time block. Typing activity and time block do not cause significant changes to the wrist anthropometric measurements. The wrist measurements remained similar across all the time blocks in the three conditions. Subsequently, the wrist extensions and ulnar deviations were significantly higher in both the typing I and typing II conditions than in the control condition for both wrists (ptyping I and typing II conditions after the typing task than before the typing task. The MNCSA significantly decreased in the recovery phase after the typing task. This study demonstrated the immediate changes in the median nerve after continuous keyboard typing. Changes in the median nerve were greater during typing using a keyboard tilted at 20° than during typing using a keyboard tilted at 0°. The main findings suggest wrist posture near to neutral position caused lower changes of the median nerve.

  3. Operational quantum theory without predefined time

    International Nuclear Information System (INIS)

    Oreshkov, Ognyan; Cerf, Nicolas J

    2016-01-01

    The standard formulation of quantum theory assumes a predefined notion of time. This is a major obstacle in the search for a quantum theory of gravity, where the causal structure of space-time is expected to be dynamical and fundamentally probabilistic in character. Here, we propose a generalized formulation of quantum theory without predefined time or causal structure, building upon a recently introduced operationally time-symmetric approach to quantum theory. The key idea is a novel isomorphism between transformations and states which depends on the symmetry transformation of time reversal. This allows us to express the time-symmetric formulation in a time-neutral form with a clear physical interpretation, and ultimately drop the assumption of time. In the resultant generalized formulation, operations are associated with regions that can be connected in networks with no directionality assumed for the connections, generalizing the standard circuit framework and the process matrix framework for operations without global causal order. The possible events in a given region are described by positive semidefinite operators on a Hilbert space at the boundary, while the connections between regions are described by entangled states that encode a nontrivial symmetry and could be tested in principle. We discuss how the causal structure of space-time could be understood as emergent from properties of the operators on the boundaries of compact space-time regions. The framework is compatible with indefinite causal order, timelike loops, and other acausal structures. (paper)

  4. Permasalahan P-Hub Median Dengan Lintasan Terpendek

    OpenAIRE

    Pasaribu, Raja David

    2013-01-01

    Hub are facilities that serve as sorting, switching, and transhipment in a transportation network. P-hub median problem is a discrete case location allocation problem which all hub is fully connected. In this paper will be intoduced Mixed Integrer Linear Programming (MILP) formulation models of cost for p-hub median problem allocation for uncapacitaced single allocation p-hub median(USApHMP). In this paper also introduced Floyd-Warshall shortest path algorithm to solve p-hub median problems a...

  5. On the time evolution operator for time-dependent quadratic Hamiltonians

    International Nuclear Information System (INIS)

    Fernandez, F.M.

    1989-01-01

    The Schroedinger equation with a time-dependent quadratic Hamiltonian is investigated. The time-evolution operator is written as a product of exponential operators determined by the Heisenberg equations of motion. This product operator is shown to be global in the occupation number representation when the Hamiltonian is Hermitian. The success of some physical applications of the product-form representation is explained

  6. Time-critical multirate scheduling using contemporary real-time operating system services

    Science.gov (United States)

    Eckhardt, D. E., Jr.

    1983-01-01

    Although real-time operating systems provide many of the task control services necessary to process time-critical applications (i.e., applications with fixed, invariant deadlines), it may still be necessary to provide a scheduling algorithm at a level above the operating system in order to coordinate a set of synchronized, time-critical tasks executing at different cyclic rates. The scheduling requirements for such applications and develops scheduling algorithms using services provided by contemporary real-time operating systems.

  7. The Ultrasonographic Findings of Bifid Median Nerve

    International Nuclear Information System (INIS)

    Park, Hee Jin; Park, Noh Hyuck; Joh, Joon Hee; Lee, Sung Moon

    2009-01-01

    We wanted to evaluate the ultrasonographic findings of bifid median nerve and its clinical significance. We retrospectively reviewed five cases (three men and two women, mean age: 54 years) of incidentally found bifid median nerve from 264 cases of clinically suspected carpal-tunnel syndrome that were seen at our hospital during last 6 years. Doppler sonography was performed in all five cases and MR angiography was done in one case for detecting a persistent median artery. The difference (ΔCSA) between the sum of the cross-sectional areas of the bifid median nerve at the pisiform level (CSA2) and the cross-sectional area proximal to the bifurcation(CSA1) was calculated. The incidence of a bifid median nerve was 1.9%. All the patients presented with a tingling sensation on a hand and two patients had nocturnal pain. All the cases showed bifurcation of the nerve bundle proximal to the carpal tunnel. The margins appeared relatively smooth and each bundle showed a characteristic fascicular pattern. A persistent median artery was noted between the bundles in four cases. ΔCSA was more than 2 mm 2 in four cases. Bifid median nerve with a persistent median artery is a relatively rare normal variance and these are very important findings before performing surgical intervention to avoid potential nerve injury and massive bleeding. We highly suggest that radiologists should understand the anatomical characteristics of this anomaly and make efforts to detect it

  8. Testing the gravity p-median model empirically

    Directory of Open Access Journals (Sweden)

    Kenneth Carling

    2015-12-01

    Full Text Available Regarding the location of a facility, the presumption in the widely used p-median model is that the customer opts for the shortest route to the nearest facility. However, this assumption is problematic on free markets since the customer is presumed to gravitate to a facility by the distance to and the attractiveness of it. The recently introduced gravity p-median model offers an extension to the p-median model that account for this. The model is therefore potentially interesting, although it has not yet been implemented and tested empirically. In this paper, we have implemented the model in an empirical problem of locating vehicle inspections, locksmiths, and retail stores of vehicle spare-parts for the purpose of investigating its superiority to the p-median model. We found, however, the gravity p-median model to be of limited use for the problem of locating facilities as it either gives solutions similar to the p-median model, or it gives unstable solutions due to a non-concave objective function.

  9. Switching non-local vector median filter

    Science.gov (United States)

    Matsuoka, Jyohei; Koga, Takanori; Suetake, Noriaki; Uchino, Eiji

    2016-04-01

    This paper describes a novel image filtering method that removes random-valued impulse noise superimposed on a natural color image. In impulse noise removal, it is essential to employ a switching-type filtering method, as used in the well-known switching median filter, to preserve the detail of an original image with good quality. In color image filtering, it is generally preferable to deal with the red (R), green (G), and blue (B) components of each pixel of a color image as elements of a vectorized signal, as in the well-known vector median filter, rather than as component-wise signals to prevent a color shift after filtering. By taking these fundamentals into consideration, we propose a switching-type vector median filter with non-local processing that mainly consists of a noise detector and a noise removal filter. Concretely, we propose a noise detector that proactively detects noise-corrupted pixels by focusing attention on the isolation tendencies of pixels of interest not in an input image but in difference images between RGB components. Furthermore, as the noise removal filter, we propose an extended version of the non-local median filter, we proposed previously for grayscale image processing, named the non-local vector median filter, which is designed for color image processing. The proposed method realizes a superior balance between the preservation of detail and impulse noise removal by proactive noise detection and non-local switching vector median filtering, respectively. The effectiveness and validity of the proposed method are verified in a series of experiments using natural color images.

  10. Time Operator in Relativistic Quantum Mechanics

    Science.gov (United States)

    Khorasani, Sina

    2017-07-01

    It is first shown that the Dirac’s equation in a relativistic frame could be modified to allow discrete time, in agreement to a recently published upper bound. Next, an exact self-adjoint 4 × 4 relativistic time operator for spin-1/2 particles is found and the time eigenstates for the non-relativistic case are obtained and discussed. Results confirm the quantum mechanical speculation that particles can indeed occupy negative energy levels with vanishingly small but non-zero probablity, contrary to the general expectation from classical physics. Hence, Wolfgang Pauli’s objection regarding the existence of a self-adjoint time operator is fully resolved. It is shown that using the time operator, a bosonic field referred here to as energons may be created, whose number state representations in non-relativistic momentum space can be explicitly found.

  11. Range Selection and Median

    DEFF Research Database (Denmark)

    Jørgensen, Allan Grønlund; Larsen, Kasper Green

    2011-01-01

    and several natural special cases thereof. The rst special case is known as range median, which arises when k is xed to b(j 􀀀 i + 1)=2c. The second case, denoted prex selection, arises when i is xed to 0. Finally, we also consider the bounded rank prex selection problem and the xed rank range......Range selection is the problem of preprocessing an input array A of n unique integers, such that given a query (i; j; k), one can report the k'th smallest integer in the subarray A[i];A[i+1]; : : : ;A[j]. In this paper we consider static data structures in the word-RAM for range selection...... selection problem. In the former, data structures must support prex selection queries under the assumption that k for some value n given at construction time, while in the latter, data structures must support range selection queries where k is xed beforehand for all queries. We prove cell probe lower bounds...

  12. Median Nerve Conduction in Healthy Nigerians: Normative Data

    African Journals Online (AJOL)

    of median nerve disease using multiple studies, and rendering ... Aim: To develop normative values for motor and sensory median nerve ..... Table 5: Comparison of median motor nerve conduction study parameters to studies elsewhere. Study.

  13. Relationships between the Brook Street Terrane and Median Tectonic Zone (Median Batholith) : evidence from Jurassic conglomerates

    International Nuclear Information System (INIS)

    Tulloch, A.J.; Kimbrough, D.L.; Landis, C.A.; Mortimer, N.; Johnston, M.R.

    1999-01-01

    U-Pb zircon ages of 237-180 Ma and c. 280 Ma of seven granitoid clasts from the Rainy River Conglomerate which lies within the eastern Median Tectonic Zone (Median Batholith) in Nelson, and the Barretts Formation of the Brook Street Terrane in Southland, constrain the depositional ages of both units to be no older than c. 180-200 Ma (Early Jurassic). The minimum age of the Rainy River Conglomerate is constrained by the 147 +2 -1 Ma (Latest Jurassic) emplacement age of the One Mile Gabbronorite (new name: previously western Buller Diorite). The ages and chemistry of five of the granitoid clasts are broadly compatible with derivation from rocks that are now represented by Triassic plutons of the Median Tectonic Zone (Median Batholith), although ages as young as 180 Ma are slightly outside the range of the latter as currently exposed in New Zealand. The age (273-290 Ma, 237 +/- 3 Ma) and chemistry of the other two clasts (one each from Rainy River Conglomerate and Barretts Formation) suggest derivation from the Brook Street Terrane. Similarity in stratigraphic age, depositional characteristics, granitoid clast ages and composition between Rainy River Conglomerate and Barretts Formation suggests that they are broadly correlative and collectively overlapped a combined Brook Street Terrane - Median Batholith (MTZ) before the Late Jurassic (147 +2 -1 Ma). Sedimentary overlap may also have continued across to Middle Jurassic conglomeratic strata in the Murihiku Terrane to the east of the Brook Street Terrane. A U-Pb zircon age of 261 +/- 2 Ma is reported for Pourakino Trondhjemite of the Brook Street Terrane. (author). 56 refs., 10 figs., 4 tabs

  14. Median and ulnar neuropathies in university guitarists.

    Science.gov (United States)

    Kennedy, Rachel H; Hutcherson, Kimberly J; Kain, Jennifer B; Phillips, Alicia L; Halle, John S; Greathouse, David G

    2006-02-01

    Descriptive study. To determine the presence of median and ulnar neuropathies in both upper extremities of university guitarists. Peripheral nerve entrapment syndromes of the upper extremities are well documented in musicians. Guitarists and plucked-string musicians are at risk for entrapment neuropathies in the upper extremities and are prone to mild neurologic deficits. Twenty-four volunteer male and female guitarists (age range, 18-26 years) were recruited from the Belmont University School of Music and the Vanderbilt University Blair School of Music. Individuals were excluded if they were pregnant or had a history of recent upper extremity or neck injury. Subjects completed a history form, were interviewed, and underwent a physical examination. Nerve conduction status of the median and ulnar nerves of both upper extremities was obtained by performing motor, sensory, and F-wave (central) nerve conduction studies. Descriptive statistics of the nerve conduction study variables were computed using Microsoft Excel. Six subjects had positive findings on provocative testing of the median and ulnar nerves. Otherwise, these guitarists had normal upper extremity neural and musculoskeletal function based on the history and physical examinations. When comparing the subjects' nerve conduction study values with a chart of normal nerve conduction studies values, 2 subjects had prolonged distal motor latencies (DMLs) of the left median nerve of 4.3 and 4.7 milliseconds (normal, DMLs are compatible with median neuropathy at or distal to the wrist. Otherwise, all electrophysiological variables were within normal limits for motor, sensory, and F-wave (central) values. However, comparison studies of median and ulnar motor latencies in the same hand demonstrated prolonged differences of greater than 1.0 milliseconds that affected the median nerve in 2 additional subjects, and identified contralateral limb involvement in a subject with a prolonged distal latency. The other 20

  15. Bayesian median regression for temporal gene expression data

    Science.gov (United States)

    Yu, Keming; Vinciotti, Veronica; Liu, Xiaohui; 't Hoen, Peter A. C.

    2007-09-01

    Most of the existing methods for the identification of biologically interesting genes in a temporal expression profiling dataset do not fully exploit the temporal ordering in the dataset and are based on normality assumptions for the gene expression. In this paper, we introduce a Bayesian median regression model to detect genes whose temporal profile is significantly different across a number of biological conditions. The regression model is defined by a polynomial function where both time and condition effects as well as interactions between the two are included. MCMC-based inference returns the posterior distribution of the polynomial coefficients. From this a simple Bayes factor test is proposed to test for significance. The estimation of the median rather than the mean, and within a Bayesian framework, increases the robustness of the method compared to a Hotelling T2-test previously suggested. This is shown on simulated data and on muscular dystrophy gene expression data.

  16. Time course and predictors of median nerve conduction after carpal tunnel release.

    Science.gov (United States)

    Rotman, Mitchell B; Enkvetchakul, Bobby V; Megerian, J Thomas; Gozani, Shai N

    2004-05-01

    To identify predictors of outcome and of electrophysiologic recovery in patients with carpal tunnel syndrome (CTS) treated by endoscopic carpal tunnel release using a nerve conduction testing system (NC-Stat; NEUROMetrix, Inc, Waltham, MA). Validity of the automated nerve conduction testing system was shown by comparing presurgical distal motor latencies (DMLs) against a reference obtained by referral to an electromyography laboratory. The DML was evaluated in 48 patients with CTS. Measurements were obtained within 1 hour of surgery and at 2 weeks, 6 weeks, 3 months, and 6 months after carpal tunnel release. Presurgical and postsurgical DMLs were then compared and correlated with variables and possible predictors of outcome including age, body mass index, gender, and presurgical DMLs. The automated nerve conduction testing system DMLs matched those of reference electromyography/nerve conduction study values with high correlation. Sensitivity of the automated nerve conduction testing system when compared with a standardized CTS case definition was 89%, with a specificity of 95%. A significant correlation was found between the DML before release and the DML 1 hour after release. Moreover, maximal postsurgical DML improvement was highly dependent on the presurgical DML, with no improvement shown for the 6-ms group. Among the clinical variables of age, gender, and body mass index only age was mildly predictive of postrelease DML changes at 6 months. No other correlations between clinical variables and postsurgical DMLs were significant. In addition the predictive value of age was lost when combined with the presurgical DML in a multivariate analysis. Postsurgical changes in the median nerve DML were highly dependent on the prerelease latency. The sensitivity and specificity of a nerve conduction monitoring system in detecting and aiding in the diagnosis of CTS is useful in the long-term management of patients with CTS and can aid in determining the level of improvement

  17. Effect of Resident Involvement on Operative Time and Operating Room Staffing Costs.

    Science.gov (United States)

    Allen, Robert William; Pruitt, Mark; Taaffe, Kevin M

    The operating room (OR) is a major driver of hospital costs; therefore, operative time is an expensive resource. The training of surgical residents must include time spent in the OR, but that experience comes with a cost to the surgeon and hospital. The objective of this article is to determine the effect of surgical resident involvement in the OR on operative time and subsequent hospital labor costs. The Kruskal-Wallis statistical test is used to determine whether or not there is a difference in operative times between 2 groups of cases (with residents and without residents). This difference leads to an increased cost in associated hospital labor costs for the group with the longer operative time. Cases were performed at Greenville Memorial Hospital. Greenville Memorial Hospital is part of the larger healthcare system, Greenville Health System, located in Greenville, SC and is a level 1 trauma center with up to 33 staffed ORs. A total of 84,997 cases were performed at the partnering hospital between January 1st, 2011 and July 31st, 2015. Cases were only chosen for analysis if there was only one CPT code associated with the case and there were more than 5 observations for each group being studied. This article presents a comprehensive retrospective analysis of 29,134 cases covering 246 procedures. The analysis shows that 45 procedures took significantly longer with a resident present in the room. The average increase in operative time was 4.8 minutes and the cost per minute of extra operative time was determined to be $9.57 per minute. OR labor costs at the partnering hospital was found to be $2,257,433, or $492,889 per year. Knowing the affect on operative time and OR costs allows managers to make smart decisions when considering alternative educational and training techniques. In addition, knowing the connection between residents in the room and surgical duration could help provide better estimates of surgical time in the future and increase the predictability of

  18. Separate patient serum sodium medians from males and females provide independent information on analytical bias.

    Science.gov (United States)

    Hansen, Steen Ingemann; Petersen, Per Hyltoft; Lund, Flemming; Fraser, Callum G; Sölétormos, György

    2017-10-26

    During monitoring of monthly medians of results from patients undertaken to assess analytical stability in routine laboratory performance, the medians for serum sodium for male and female patients were found to be significantly related. Daily, weekly and monthly patient medians of serum sodium for both male and female patients were calculated from results obtained on samples from the population >18 years on three analysers in the hospital laboratory. The half-range of medians was applied as an estimate of the maximum bias. Further, the ratios between the two medians were calculated. The medians of both genders demonstrated dispersions over time, but they were closely connected in like patterns, which were confirmed by the half-range of the ratios of medians for males and females that varied from 0.36% for daily, 0.14% for weekly and 0.036% for monthly ratios over all instruments. The tight relationship between the gender medians for serum sodium is only possible when raw laboratory data are used for calculation. The two patient medians can be used to confirm both and are useful as independent estimates of analytical bias during constant calibration periods. In contrast to the gender combined median, the estimate of analytical bias can be confirmed further by calculation of the ratios of medians for males and females.

  19. Guidance concepts for time-based flight operations

    Science.gov (United States)

    Vicroy, Dan D.

    1990-01-01

    Airport congestion and the associated delays are severe in today's airspace system and are expected to increase. NASA and the FAA is investigating various methods of alleviating this problem through new technology and operational procedures. One concept for improving airspace productivity is time-based control of aircraft. Research to date has focused primarily on the development of time-based flight management systems and Air Traffic Control operational procedures. Flight operations may, however, require special onboard guidance in order to satisfy the Air Traffic Control imposed time constraints. The results are presented of a simulation study aimed at evaluating several time-based guidance concepts in terms of tracking performance, pilot workload, and subjective preference. The guidance concepts tested varied in complexity from simple digital time-error feedback to an advanced time-referenced-energy guidance scheme.

  20. Motor operated valve stroke timing; is there value?

    International Nuclear Information System (INIS)

    Green, K.; Rosch, F. Jr.; Neckowicz, T.

    1990-01-01

    Both ASME Section XI, Subsection IWV and ASME/ANSI OMa-1988, Part 10 require stroke timing of certain power operated valves. This requirement is intended to detect valve degradation and subsequent maintenance, repair or replacement needs. However, the adequacy of stroke timing, especially for motor operated valves, has met much skepticism in the industry. This paper will demonstrate that stroke timing for ac motor operated valves is inadequate and provide a non-intrusive testing alternative. It will also discuss the value of stroke timing for dc motor operated valves

  1. Single-Use Energy Sources and Operating Room Time for Laparoscopic Hysterectomy: A Randomized Controlled Trial.

    Science.gov (United States)

    Holloran-Schwartz, M Brigid; Gavard, Jeffrey A; Martin, Jared C; Blaskiewicz, Robert J; Yeung, Patrick P

    2016-01-01

    To compare the intraoperative direct costs of a single-use energy device with reusable energy devices during laparoscopic hysterectomy. A randomized controlled trial (Canadian Task Force Classification I). An academic hospital. Forty-six women who underwent laparoscopic hysterectomy from March 2013 to September 2013. Each patient served as her own control. One side of the uterine attachments was desiccated and transected with the single-use device (Ligasure 5-mm Blunt Tip LF1537 with the Force Triad generator). The other side was desiccated and transected with reusable bipolar forceps (RoBi 5 mm), and transected with monopolar scissors using the same Covidien Force Triad generator. The instrument approach used was randomized to the attending physician who was always on the patient's left side. Resident physicians always operated on the patient's right side and used the converse instruments of the attending physician. Start time was recorded at the utero-ovarian pedicle and end time was recorded after transection of the uterine artery on the same side. Costs included the single-use device; amortized costs of the generator, reusable instruments, and cords; cleaning and packaging of reusable instruments; and disposal of the single-use device. Operating room time was $94.14/min. We estimated that our single use-device cost $630.14 and had a total time savings of 6.7 min per case, or 3.35 min per side, which could justify the expense of the device. The single-use energy device had significant median time savings (-4.7 min per side, p energy device that both desiccates and cuts significantly reduced operating room time to justify its own cost, and it also reduced total intraoperative direct costs during laparoscopic hysterectomy in our institution. Operating room cost per minute varies between institutions and must be considered before generalizing our results. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  2. Real-time multi-task operators support system

    International Nuclear Information System (INIS)

    Wang He; Peng Minjun; Wang Hao; Cheng Shouyu

    2005-01-01

    The development in computer software and hardware technology and information processing as well as the accumulation in the design and feedback from Nuclear Power Plant (NPP) operation created a good opportunity to develop an integrated Operator Support System. The Real-time Multi-task Operator Support System (RMOSS) has been built to support the operator's decision making process during normal and abnormal operations. RMOSS consists of five system subtasks such as Data Collection and Validation Task (DCVT), Operation Monitoring Task (OMT), Fault Diagnostic Task (FDT), Operation Guideline Task (OGT) and Human Machine Interface Task (HMIT). RMOSS uses rule-based expert system and Artificial Neural Network (ANN). The rule-based expert system is used to identify the predefined events in static conditions and track the operation guideline through data processing. In dynamic status, Back-Propagation Neural Network is adopted for fault diagnosis, which is trained with the Genetic Algorithm. Embedded real-time operation system VxWorks and its integrated environment Tornado II are used as the RMOSS software cross-development. VxGUI is used to design HMI. All of the task programs are designed in C language. The task tests and function evaluation of RMOSS have been done in one real-time full scope simulator. Evaluation results show that each task of RMOSS is capable of accomplishing its functions. (authors)

  3. MEDIAN: Wireless broadband LAN for multimedia applications

    NARCIS (Netherlands)

    Vliet, P.J. van

    1998-01-01

    MEDIAN is one of the projects in the mobile domain of the Advanced Communications Technologies and Services (ACTS) programme of the European Commission. The main obiective of the MEDIAN project is to evaluate and implement a high speed Wireless Customer Premises / Local Area Network (WCPN/WLAN)

  4. On Preliminary Test Estimator for Median

    OpenAIRE

    Okazaki, Takeo; 岡崎, 威生

    1990-01-01

    The purpose of the present paper is to discuss about estimation of median with a preliminary test. Two procedures are presented, one uses Median test and the other uses Wilcoxon two-sample test for the preliminary test. Sections 3 and 4 give mathematical formulations of such properties, including mean square errors with one specified case. Section 5 discusses their optimal significance levels of the preliminary test and proposes their numerical values by Monte Carlo method. In addition to mea...

  5. Anterolateral minithoracotomy versus median sternotomy for the treatment of congenital heart defects: a meta-analysis and systematic review

    Directory of Open Access Journals (Sweden)

    Ding Chao

    2012-05-01

    Full Text Available Abstract Background Anterolateral Minithoracotomy (ALMT for the radical correction of Congenital Heart Defects is an alternative to Median Sternotomy (MS due to reduce operative trauma accelerating recovery and yield a better cosmetic outcome after surgery. Our purpose is to conduct whether ALMT would bring more short-term benefits to patients than conventional Median Sternotomy by using a meta-analysis of case–control study in the published English Journal. Methods 6 case control studies published in English from 1997 to 2011 were identified and synthesized to compare the short-term postoperative outcomes between ALMT and MS. These outcomes were cardiopulmonary bypass time, aortic cross-clamp time, intubation time, intensive care unit stay time, and postoperative hospital stay time. Results ALMT had significantly longer cardiopulmonary bypass times (8.00 min more, 95% CI 0.36 to 15.64 min, p = 0.04. Some evidence proved that aortic cross-clamp time of ALMT was longer, yet not significantly (2.38 min more, 95% CI −0.15 to 4.91 min, p = 0.06. In addition, ALMT had significantly shorter intubation time (1.66 hrs less, 95% CI −3.05 to −0.27 hrs, p = 0.02. Postoperative hospital stay time was significantly shorter with ALMT (1.52 days less, 95% CI −2.71 to −0.33 days, p = 0.01. Some evidence suggested a reduction in ICU stay time in the ALMT group. However, this did not prove to be statistically significant (0.88 days less, 95% CI −0.81 to 0.04 days, p = 0.08. Conclusion ALMT can bring more benefits to patients with Congenital Heart Defects by reducing intubation time and postoperative hospital stay time, though ALMT has longer CPB time and aortic cross-clamp time.

  6. Anterolateral minithoracotomy versus median sternotomy for the treatment of congenital heart defects: a meta-analysis and systematic review.

    Science.gov (United States)

    Ding, Chao; Wang, Chunmao; Dong, Aiqiang; Kong, Minjian; Jiang, Daming; Tao, Kaiyu; Shen, Zhonghua

    2012-05-04

    Anterolateral Minithoracotomy (ALMT) for the radical correction of Congenital Heart Defects is an alternative to Median Sternotomy (MS) due to reduce operative trauma accelerating recovery and yield a better cosmetic outcome after surgery. Our purpose is to conduct whether ALMT would bring more short-term benefits to patients than conventional Median Sternotomy by using a meta-analysis of case-control study in the published English Journal. 6 case control studies published in English from 1997 to 2011 were identified and synthesized to compare the short-term postoperative outcomes between ALMT and MS. These outcomes were cardiopulmonary bypass time, aortic cross-clamp time, intubation time, intensive care unit stay time, and postoperative hospital stay time. ALMT had significantly longer cardiopulmonary bypass times (8.00 min more, 95% CI 0.36 to 15.64 min, p = 0.04). Some evidence proved that aortic cross-clamp time of ALMT was longer, yet not significantly (2.38 min more, 95% CI -0.15 to 4.91 min, p = 0.06). In addition, ALMT had significantly shorter intubation time (1.66 hrs less, 95% CI -3.05 to -0.27 hrs, p = 0.02). Postoperative hospital stay time was significantly shorter with ALMT (1.52 days less, 95% CI -2.71 to -0.33 days, p = 0.01). Some evidence suggested a reduction in ICU stay time in the ALMT group. However, this did not prove to be statistically significant (0.88 days less, 95% CI -0.81 to 0.04 days, p = 0.08). ALMT can bring more benefits to patients with Congenital Heart Defects by reducing intubation time and postoperative hospital stay time, though ALMT has longer CPB time and aortic cross-clamp time.

  7. Real-time operating system timing jitter and its impact on motor control

    Science.gov (United States)

    Proctor, Frederick M.; Shackleford, William P.

    2001-12-01

    General-purpose microprocessors are increasingly being used for control applications due to their widespread availability and software support for non-control functions like networking and operator interfaces. Two classes of real-time operating systems (RTOS) exist for these systems. The traditional RTOS serves as the sole operating system, and provides all OS services. Examples include ETS, LynxOS, QNX, Windows CE and VxWorks. RTOS extensions add real-time scheduling capabilities to non-real-time OSes, and provide minimal services needed for the time-critical portions of an application. Examples include RTAI and RTL for Linux, and HyperKernel, OnTime and RTX for Windows NT. Timing jitter is an issue in these systems, due to hardware effects such as bus locking, caches and pipelines, and software effects from mutual exclusion resource locks, non-preemtible critical sections, disabled interrupts, and multiple code paths in the scheduler. Jitter is typically on the order of a microsecond to a few tens of microseconds for hard real-time operating systems, and ranges from milliseconds to seconds in the worst case for soft real-time operating systems. The question of its significance on the performance of a controller arises. Naturally, the smaller the scheduling period required for a control task, the more significant is the impact of timing jitter. Aside from this intuitive relationship is the greater significance of timing on open-loop control, such as for stepper motors, than for closed-loop control, such as for servo motors. Techniques for measuring timing jitter are discussed, and comparisons between various platforms are presented. Techniques to reduce jitter or mitigate its effects are presented. The impact of jitter on stepper motor control is analyzed.

  8. Short Operative Duration and Surgical Site Infection Risk in Hip and Knee Arthroplasty Procedures.

    Science.gov (United States)

    Dicks, Kristen V; Baker, Arthur W; Durkin, Michael J; Anderson, Deverick J; Moehring, Rebekah W; Chen, Luke F; Sexton, Daniel J; Weber, David J; Lewis, Sarah S

    2015-12-01

    To determine the association (1) between shorter operative duration and surgical site infection (SSI) and (2) between surgeon median operative duration and SSI risk among first-time hip and knee arthroplasties. Retrospective cohort study A total of 43 community hospitals located in the southeastern United States. Adults who developed SSIs according to National Healthcare Safety Network criteria within 365 days of first-time knee or hip arthroplasties performed between January 1, 2008 and December 31, 2012. Log-binomial regression models estimated the association (1) between operative duration and SSI outcome and (2) between surgeon median operative duration and SSI outcome. Hip and knee arthroplasties were evaluated in separate models. Each model was adjusted for American Society of Anesthesiology score and patient age. A total of 25,531 hip arthroplasties and 42,187 knee arthroplasties were included in the study. The risk of SSI in knee arthroplasties with an operative duration shorter than the 25th percentile was 0.40 times the risk of SSI in knee arthroplasties with an operative duration between the 25th and 75th percentile (risk ratio [RR], 0.40; 95% confidence interval [CI], 0.38-0.56; Poperative duration did not demonstrate significant association with SSI for hip arthroplasties (RR, 1.04; 95% CI, 0.79-1.37; P=.36). Knee arthroplasty surgeons with shorter median operative durations had a lower risk of SSI than surgeons with typical median operative durations (RR, 0.52; 95% CI, 0.43-0.64; Poperative durations were not associated with a higher SSI risk for knee or hip arthroplasty procedures in our analysis.

  9. Reusable single-port access device shortens operative time and reduces operative costs.

    Science.gov (United States)

    Shussman, Noam; Kedar, Asaf; Elazary, Ram; Abu Gazala, Mahmoud; Rivkind, Avraham I; Mintz, Yoav

    2014-06-01

    In recent years, single-port laparoscopy (SPL) has become an attractive approach for performing surgical procedures. The pitfalls of this approach are technical and financial. Financial concerns are due to the increased cost of dedicated devices and prolonged operating room time. Our aim was to calculate the cost of SPL using a reusable port and instruments in order to evaluate the cost difference between this approach to SPL using the available disposable ports and standard laparoscopy. We performed 22 laparoscopic procedures via the SPL approach using a reusable single-port access system and reusable laparoscopic instruments. These included 17 cholecystectomies and five other procedures. Operative time, postoperative length of stay (LOS) and complications were prospectively recorded and were compared with similar data from our SPL database. Student's t test was used for statistical analysis. SPL was successfully performed in all cases. Mean operative time for cholecystectomy was 72 min (range 40-116). Postoperative LOS was not changed from our standard protocols and was 1.1 days for cholecystectomy. The postoperative course was within normal limits for all patients and perioperative morbidity was recorded. Both operative time and length of hospital stay were shorter for the 17 patients who underwent cholecystectomy using a reusable port than for the matched previous 17 SPL cholecystectomies we performed (p cost difference. Operating with a reusable port ended up with an average cost savings of US$388 compared with using disposable ports, and US$240 compared with standard laparoscopy. Single-port laparoscopic surgery is a technically challenging and expensive surgical approach. Financial concerns among others have been advocated against this approach; however, we demonstrate herein that using a reusable port and instruments reduces operative time and overall operative costs, even beyond the cost of standard laparoscopy.

  10. Operator of Time and Generalized Schrödinger Equation

    Directory of Open Access Journals (Sweden)

    Slobodan Prvanović

    2018-01-01

    Full Text Available The equation describing the change of the state of the quantum system with respect to energy is introduced within the framework of the self-adjoint operator of time in nonrelativistic quantum mechanics. In this proposal, the operator of time appears to be the generator of the change of the energy, while the operator of energy that is conjugate to the operator of time generates the time evolution. Two examples, one with discrete time and the other with continuous one, are given and the generalization of Schrödinger equation is proposed.

  11. Quantum arrival times and operator normalization

    International Nuclear Information System (INIS)

    Hegerfeldt, Gerhard C.; Seidel, Dirk; Gonzalo Muga, J.

    2003-01-01

    A recent approach to arrival times used the fluorescence of an atom entering a laser illuminated region, and the resulting arrival-time distribution was close to the axiomatic distribution of Kijowski, but not exactly equal, neither in limiting cases nor after compensation of reflection losses by normalization on the level of expectation values. In this paper we employ a normalization on the level of operators, recently proposed in a slightly different context. We show that in this case the axiomatic arrival-time distribution of Kijowski is recovered as a limiting case. In addition, it is shown that Allcock's complex potential model is also a limit of the physically motivated fluorescence approach and connected to Kijowski's distribution through operator normalization

  12. An assessment of the quality indicators of operative and non-operative times in a public university hospital.

    Science.gov (United States)

    Costa, Altair da Silva; Leão, Luiz Eduardo Villaça; Novais, Maykon Anderson Pires de; Zucchi, Paola

    2015-01-01

    To assess the operative time indicators in a public university hospital. A descriptive cross-sectional study was conducted using data from operating room database. The sample was obtained from January 2011 to January 2012. The operations performed in sequence in the same operating room, between 7:00 am and 5:00 pm, elective or emergency, were included. The procedures with incomplete data in the system were excluded, as well as the operations performed after 5:00 pm or on weekends or holidays. We measured the operative and non-operative time of 8,420 operations. The operative time (mean and standard deviation) of anesthesias and operations were 177.6 ± 110 and 129.8 ± 97.1 minutes, respectively. The total time of the patient in operative room (mean and standard deviation) was 196.8 ± 113.2. The non-operative time, e.g., between the arrival of the patient and the onset of anesthesia was 14.3 ± 17.3 minutes. The time to set the next patient in operating room was 119.8 ± 79.6 minutes. Our total non-operative time was 155 minutes. Delays frequently occurred in our operating room and had a major effect on patient flow and resource utilization. The non-operative time was longer than the operative time. It is possible to increase the operating room capacity by management and training of the professionals involved. The indicators provided a tool to improve operating room efficiency.

  13. Dual pathology proximal median nerve compression of the forearm.

    LENUS (Irish Health Repository)

    Murphy, Siun M

    2013-12-01

    We report an unusual case of synchronous pathology in the forearm- the coexistence of a large lipoma of the median nerve together with an osteochondroma of the proximal ulna, giving rise to a dual proximal median nerve compression. Proximal median nerve compression neuropathies in the forearm are uncommon compared to the prevalence of distal compression neuropathies (eg Carpal Tunnel Syndrome). Both neural fibrolipomas (Refs. 1,2) and osteochondromas of the proximal ulna (Ref. 3) in isolation are rare but well documented. Unlike that of a distal compression, a proximal compression of the median nerve will often have a definite cause. Neural fibrolipoma, also called fibrolipomatous hamartoma are rare, slow-growing, benign tumours of peripheral nerves, most often occurring in the median nerve of younger patients. To our knowledge, this is the first report of such dual pathology in the same forearm, giving rise to a severe proximal compression of the median nerve. In this case, the nerve was being pushed anteriorly by the osteochondroma, and was being compressed from within by the intraneural lipoma. This unusual case highlights the advantage of preoperative imaging as part of the workup of proximal median nerve compression.

  14. Portfolio optimization using median-variance approach

    Science.gov (United States)

    Wan Mohd, Wan Rosanisah; Mohamad, Daud; Mohamed, Zulkifli

    2013-04-01

    Optimization models have been applied in many decision-making problems particularly in portfolio selection. Since the introduction of Markowitz's theory of portfolio selection, various approaches based on mathematical programming have been introduced such as mean-variance, mean-absolute deviation, mean-variance-skewness and conditional value-at-risk (CVaR) mainly to maximize return and minimize risk. However most of the approaches assume that the distribution of data is normal and this is not generally true. As an alternative, in this paper, we employ the median-variance approach to improve the portfolio optimization. This approach has successfully catered both types of normal and non-normal distribution of data. With this actual representation, we analyze and compare the rate of return and risk between the mean-variance and the median-variance based portfolio which consist of 30 stocks from Bursa Malaysia. The results in this study show that the median-variance approach is capable to produce a lower risk for each return earning as compared to the mean-variance approach.

  15. Regularization of DT-MR images using a successive Fermat median filtering method.

    Science.gov (United States)

    Kwon, Kiwoon; Kim, Dongyoun; Kim, Sunghee; Park, Insung; Jeong, Jaewon; Kim, Taehwan; Hong, Cheolpyo; Han, Bongsoo

    2008-05-21

    Tractography using diffusion tensor magnetic resonance imaging (DT-MRI) is a method to determine the architecture of axonal fibers in the central nervous system by computing the direction of greatest diffusion in the white matter of the brain. To reduce the noise in DT-MRI measurements, a tensor-valued median filter, which is reported to be denoising and structure preserving in the tractography, is applied. In this paper, we proposed the successive Fermat (SF) method, successively using Fermat point theory for a triangle contained in the two-dimensional plane, as a median filtering method. We discussed the error analysis and numerical study about the SF method for phantom and experimental data. By considering the computing time and the image quality aspects of the numerical study simultaneously, we showed that the SF method is much more efficient than the simple median (SM) and gradient descents (GD) methods.

  16. Regularization of DT-MR images using a successive Fermat median filtering method

    International Nuclear Information System (INIS)

    Kwon, Kiwoon; Kim, Dongyoun; Kim, Sunghee; Park, Insung; Jeong, Jaewon; Kim, Taehwan; Hong, Cheolpyo; Han, Bongsoo

    2008-01-01

    Tractography using diffusion tensor magnetic resonance imaging (DT-MRI) is a method to determine the architecture of axonal fibers in the central nervous system by computing the direction of greatest diffusion in the white matter of the brain. To reduce the noise in DT-MRI measurements, a tensor-valued median filter, which is reported to be denoising and structure preserving in the tractography, is applied. In this paper, we proposed the successive Fermat (SF) method, successively using Fermat point theory for a triangle contained in the two-dimensional plane, as a median filtering method. We discussed the error analysis and numerical study about the SF method for phantom and experimental data. By considering the computing time and the image quality aspects of the numerical study simultaneously, we showed that the SF method is much more efficient than the simple median (SM) and gradient descents (GD) methods

  17. Regularization of DT-MR images using a successive Fermat median filtering method

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kiwoon; Kim, Dongyoun; Kim, Sunghee; Park, Insung; Jeong, Jaewon; Kim, Taehwan [Department of Biomedical Engineering, Yonsei University, Wonju, 220-710 (Korea, Republic of); Hong, Cheolpyo; Han, Bongsoo [Department of Radiological Science, Yonsei University, Wonju, 220-710 (Korea, Republic of)], E-mail: bshan@yonsei.ac.kr

    2008-05-21

    Tractography using diffusion tensor magnetic resonance imaging (DT-MRI) is a method to determine the architecture of axonal fibers in the central nervous system by computing the direction of greatest diffusion in the white matter of the brain. To reduce the noise in DT-MRI measurements, a tensor-valued median filter, which is reported to be denoising and structure preserving in the tractography, is applied. In this paper, we proposed the successive Fermat (SF) method, successively using Fermat point theory for a triangle contained in the two-dimensional plane, as a median filtering method. We discussed the error analysis and numerical study about the SF method for phantom and experimental data. By considering the computing time and the image quality aspects of the numerical study simultaneously, we showed that the SF method is much more efficient than the simple median (SM) and gradient descents (GD) methods.

  18. Determination of operation time function for activimeters

    International Nuclear Information System (INIS)

    Sousa, C.H.S.; Peixoto, J.G.P.; Araujo, G.; Padilha, L.G.

    2016-01-01

    Radiation detectors must pass periodically recommended quality control tests and standardized to certify the quality of measurements, however, many studies have shown that several parameters can influence the results, however, some instrument components that can not be adjusted during calibrations may have significant importance in measurement results over the operating time. This study sought to determine the influence of the use of time in the activity measurements. The results show a trend of decreased activity measured for equipment with detectors with more operating time. (author)

  19. Operational and real-time Business Intelligence

    Directory of Open Access Journals (Sweden)

    Daniela Ioana SANDU

    2008-01-01

    Full Text Available A key component of a company’s IT framework is a business intelligence (BI system. BI enables business users to report on, analyze and optimize business operations to reduce costs and increase revenues. Organizations use BI for strategic and tactical decision making where the decision-making cycle may span a time period of several weeks (e.g., campaign management or months (e.g., improving customer satisfaction.Competitive pressures coming from a very dynamic business environment are forcing companies to react faster to changing business conditions and customer requirements. As a result, there is now a need to use BI to help drive and optimize business operations on a daily basis, and, in some cases, even for intraday decision making. This type of BI is usually called operational business intelligence and real-time business intelligence.

  20. Mixed-mode Operating System for Real-time Performance

    OpenAIRE

    M.M. Hasan; S. Sultana; C.K. Foo

    2017-01-01

    The purpose of the mixed-mode system research is to handle devices with the accuracy of real-time systems and at the same time, having all the benefits and facilities of a matured Graphic User Interface (GUI) operating system which is typically nonreal-time. This mixed-mode operating system comprising of a real-time portion and a non-real-time portion was studied and implemented to identify the feasibilities and performances in practical applications (in the context of scheduled the real-time...

  1. Mixed - mode Operating System for Real - time Performance

    OpenAIRE

    Hasan M. M.; Sultana S.; Foo C.K.

    2017-01-01

    The purpose of the mixed-mode system research is to handle devices with the accuracy of real-time systems and at the same time, having all the benefits and facilities of a matured Graphic User Interface(GUI)operating system which is typicallynon-real-time. This mixed-mode operating system comprising of a real-time portion and a non-real-time portion was studied and implemented to identify the feasibilities and performances in practical applications (in the context of scheduled the real-time e...

  2. Papillary carcinoma in median aberrant thyroid (ectopic) - case report.

    Science.gov (United States)

    Hebbar K, Ashwin; K, Shashidhar; Deshmane, Vijaya Laxmi; Kumar, Veerendra; Arjunan, Ravi

    2014-06-01

    Median ectopic thyroid may be encountered anywhere from the foramen caecum to the diaphragm. Non lingual median aberrant thyroid (incomplete descent) usually found in the infrahyoid region and malignant transformation in this ectopic thyroid tissue is very rare. We report an extremely rare case of papillary carcinoma in non lingual median aberrant thyroid in a 25-year-old female. The differentiation between a carcinoma arising in the median ectopic thyroid tissue and a metastatic papillary carcinoma from an occult primary in the main thyroid gland is also discussed.

  3. Development of Kinematic Graphs of Median Nerve during Active Finger Motion: Implications of Smartphone Use.

    Directory of Open Access Journals (Sweden)

    Hoi-Chi Woo

    Full Text Available Certain hand activities cause deformation and displacement of the median nerve at the carpal tunnel due to the gliding motion of tendons surrounding it. As smartphone usage escalates, this raises the public's concern whether hand activities while using smartphones can lead to median nerve problems.The aims of this study were to 1 develop kinematic graphs and 2 investigate the associated deformation and rotational information of median nerve in the carpal tunnel during hand activities.Dominant wrists of 30 young adults were examined with ultrasonography by placing a transducer transversely on their wrist crease. Ultrasound video clips were recorded when the subject performing 1 thumb opposition with the wrist in neutral position, 2 thumb opposition with the wrist in ulnar deviation and 3 pinch grip with the wrist in neutral position. Six still images that were separated by 0.2-second intervals were then captured from the ultrasound video for the determination of 1 cross-sectional area (CSA, 2 flattening ratio (FR, 3 rotational displacement (RD and 4 translational displacement (TD of median nerve in the carpal tunnel, and these collected information of deformation, rotational and displacement of median nerve were compared between 1 two successive time points during a single hand activity and 2 different hand motions at the same time point. Finally, kinematic graphs were constructed to demonstrate the mobility of median nerve during different hand activities.Performing different hand activities during this study led to a gradual reduction in CSA of the median nerve, with thumb opposition together with the wrist in ulnar deviation causing the greatest extent of deformation of the median nerve. Thumb opposition with the wrist in ulnar deviation also led to the largest extent of TD when compared to the other two hand activities of this study. Kinematic graphs showed that the motion pathways of median nerve during different hand activities were complex

  4. On the definition of time operator in quantum mechanics

    International Nuclear Information System (INIS)

    Nowicki, A.A.

    1974-01-01

    Different approaches to the quantum-mechanical definition of time operator T are briefly discussed. In particular we define the analytic continuation of the time operator and show that one can construct its exact eigenstates. We consider also the case of a relativistic free scalar particle and discuss the notion of proper time operator S. (author)

  5. Adiabatic theorem for the time-dependent wave operator

    International Nuclear Information System (INIS)

    Viennot, David; Jolicard, Georges; Killingbeck, John P.; Perrin, Marie-Yvonne

    2005-01-01

    The application of time-dependent wave operator theory to the development of a quantum adiabatic perturbation theory is treated both theoretically and numerically, with emphasis on the description of field-matter interactions which involve short laser pulses. It is first shown that the adiabatic limit of the time-dependent wave operator corresponds to a succession of instantaneous static Bloch wave operators. Wave operator theory is then shown to be compatible with the two-time Floquet theory of light-matter interaction, thus allowing the application of Floquet theory to cases which require the use of a degenerate active space. A numerical study of some problems shows that the perturbation strength associated with nonadiabatic processes can be reduced by using multidimensional active spaces and illustrates the capacity of the wave operator approach to produce a quasiadiabatic treatment of a nominally nonadiabatic Floquet dynamical system

  6. Dual pathology proximal median nerve compression of the forearm.

    Science.gov (United States)

    Murphy, Siun M; Browne, Katherine; Tuite, David J; O'Shaughnessy, Michael

    2013-12-01

    We report an unusual case of synchronous pathology in the forearm- the coexistence of a large lipoma of the median nerve together with an osteochondroma of the proximal ulna, giving rise to a dual proximal median nerve compression. Proximal median nerve compression neuropathies in the forearm are uncommon compared to the prevalence of distal compression neuropathies (eg Carpal Tunnel Syndrome). Both neural fibrolipomas (Refs. 1,2) and osteochondromas of the proximal ulna (Ref. 3) in isolation are rare but well documented. Unlike that of a distal compression, a proximal compression of the median nerve will often have a definite cause. Neural fibrolipoma, also called fibrolipomatous hamartoma are rare, slow-growing, benign tumours of peripheral nerves, most often occurring in the median nerve of younger patients. To our knowledge, this is the first report of such dual pathology in the same forearm, giving rise to a severe proximal compression of the median nerve. In this case, the nerve was being pushed anteriorly by the osteochondroma, and was being compressed from within by the intraneural lipoma. This unusual case highlights the advantage of preoperative imaging as part of the workup of proximal median nerve compression. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. The management of right iliac fossa pain - is timing everything?

    LENUS (Irish Health Repository)

    McCartan, D P

    2012-01-31

    BACKGROUND: Right iliac fossa (RIF) pain remains the commonest clinical dilemma encountered by general surgeons. We prospectively audited the management of acute RIF pain, examining the relationship between symptom duration, use of pre-operative radiological imaging and patient outcome. METHODS: Over a six-month period, 302 patients, median age 18 years, 59% female, were admitted with RIF pain. Symptoms, clinical findings and laboratory results were documented. Patient management, timing of radiological investigations and operations, and outcome were recorded prospectively. RESULTS: Non-specific abdominal pain (26%), gynaecological (22%) and miscellaneous causes (14%) accounted for most admissions. Ultimately, 119 patients (39%) had appendicitis. Anorexia, tachycardia or rebound tenderness in the RIF significantly predicted a final diagnosis of appendicitis. Patients with perforated appendicitis (n = 29) had a longer duration of pre-hospital symptoms (median 50h) compared to those with simple appendicitis (median 17 h) (p<0.001). The use of pre-operative imaging resulted in an increased time to surgery but was not associated with increased post-operative morbidity or perforated appendicitis. CONCLUSION: The majority of patients presenting to hospital with RIF pain did not have appendicitis. Increased duration of pre-hospital symptoms was the main factor associated with perforated appendicitis. However, increased in-hospital time to theatre was not associated with perforated appendicitis or post-operative morbidity.

  8. Optimizing capital and time expenditures for drilling service operations

    Energy Technology Data Exchange (ETDEWEB)

    Zazovskiy, F Ya; Soltysyak, T I

    1980-01-01

    The operational efficiency of drilling services operations management are examined. The structure of time expenditure is analyzed for repair operations according to equipment type employed by the Ivano-Frankovsk Drilling Management under the Ukrneft' enterprise during 1977. The results of this analysis are weighed against a series of service operations carried out at industrial enterprises and connected with technical disruptions. Some of the cases examined include service competion operations outside of the industrial units when technical processes are disrupted only for the change of equipment which has outlived its usefulness and is no longer in series production. First of all, time expended for repair work can be reduced to zero during the drilling of shallow wells which do not require extensive drilling time. The actual savings, both in time and money, as far as repair work is concerned, hinges on the actual time factor for total oil depetion. An equation is provided for optimal time expenditure necessary for repair work and equipment replacement. An actual example is given from the Dolinsk UBR (Drillin Management) under the Ukrneft' enterprise where time spent on actual service operations has appeared to be less than the optimal figure cited in the above material. This is possible because of increased capital expenditures.

  9. Sosiaalisen median markkinoinnin vuosikello Weecos Oy:lle

    OpenAIRE

    Heinämäki, Lotta; Huuskonen, Leena

    2015-01-01

    Opinnäytetyön tarkoitus oli luoda kokonaisvaltainen ja selkeä suunnitelma Weecos Oy:n markkinointitoimenpiteille valituissa sosiaalisen median kanavissa. Weecos on vuonna 2012 perustettu ekologisia yrityksiä yhteen keräävä verkkokauppa-alusta. Pienestä koostaan johtuen se ei ole pystynyt toteuttamaan sosiaalisen median markkinointia toivomallaan tavalla ja markkinoinnin suunnittelu ja toteutus on ollut epäsäännöllistä. Markkinointisuunnitelman tavoitteena oli helpottaa yrityksen markkinoi...

  10. Start time delays in operating room: Different perspectives

    Directory of Open Access Journals (Sweden)

    Babita Gupta

    2011-01-01

    Full Text Available Background: Healthcare expenditure is a serious concern, with escalating costs failing to meet the expectations of quality care. The treatment capacities are limited in a hospital setting and the operating rooms (ORs. Their optimal utilization is vital in efficient hospital management. Starting late means considerable wait time for staff, patients and waste of resources. We planned an audit to assess different perspectives of the residents in surgical specialities and anesthesia and OR staff nurses so as to know the causative factors of operative delay. This can help develop a practical model to decrease start time delays in operating room (ORs. Aims: An audit to assess different perspectives of the Operating room (OR staff with respect to the varied causative factors of operative delay in the OR. To aid in the development of a practical model to decrease start time delays in ORs and facilitate on-time starts at Jai Prakash Narayan Apex Trauma centre (JPNATC, All India Institute of Medical Sciences (AIIMS, New Delhi. Methods: We prepared a questionnaire seeking the five main reasons of delay as per their perspective. Results: The available data was analysed. Analysis of the data demonstrated the common causative factors in start time operative delays as: a lack of proper planning, deficiencies in team work, communication gap and limited availability of trained supporting staff. Conclusions: The preparation of the equipment and required material for the OR cases must be done well in advance. Utilization of newer technology enables timely booking and scheduling of cases. Improved inter-departmental coordination and compliance with preanesthetic instructions needs to be ensured. It is essential that the anesthesiologists perform their work promptly, well in time . and supervise the proceedings as the OR manager. This audit is a step forward in defining the need of effective OR planning for continuous quality improvement.

  11. Real-time Testing of Operating Systems on Raspberry Pi

    OpenAIRE

    Murstad, Amund

    2016-01-01

    A subset of operating systems are called ``real time'' operating systems. While a general operating system like Windows or OSX can make no guarantee when a process gets to run, a real time one has the ability to do so. They are used for systems where the quality of the results from the operating system is not only defined by their correctness, but also by when they arrive. These kinds of systems are called Real-time Systems and can be divided into soft, hard and firm. If a deadline is missed ...

  12. A Time-Composable Operating System for the Patmos Processor

    DEFF Research Database (Denmark)

    Ziccardi, Marco; Schoeberl, Martin; Vardanega, Tullio

    2015-01-01

    -composable operating system, on top of a time-composable processor, facilitates incremental development, which is highly desirable for industry. This paper makes a twofold contribution. First, we present enhancements to the Patmos processor to allow achieving time composability at the operating system level. Second......, we extend an existing time-composable operating system, TiCOS, to make best use of advanced Patmos hardware features in the pursuit of time composability.......In the last couple of decades we have witnessed a steady growth in the complexity and widespread of real-time systems. In order to master the rising complexity in the timing behaviour of those systems, rightful attention has been given to the development of time-predictable computer architectures...

  13. Time Warp Operating System, Version 2.5.1

    Science.gov (United States)

    Bellenot, Steven F.; Gieselman, John S.; Hawley, Lawrence R.; Peterson, Judy; Presley, Matthew T.; Reiher, Peter L.; Springer, Paul L.; Tupman, John R.; Wedel, John J., Jr.; Wieland, Frederick P.; hide

    1993-01-01

    Time Warp Operating System, TWOS, is special purpose computer program designed to support parallel simulation of discrete events. Complete implementation of Time Warp software mechanism, which implements distributed protocol for virtual synchronization based on rollback of processes and annihilation of messages. Supports simulations and other computations in which both virtual time and dynamic load balancing used. Program utilizes underlying resources of operating system. Written in C programming language.

  14. Smooth time-dependent receiver operating characteristic curve estimators.

    Science.gov (United States)

    Martínez-Camblor, Pablo; Pardo-Fernández, Juan Carlos

    2018-03-01

    The receiver operating characteristic curve is a popular graphical method often used to study the diagnostic capacity of continuous (bio)markers. When the considered outcome is a time-dependent variable, two main extensions have been proposed: the cumulative/dynamic receiver operating characteristic curve and the incident/dynamic receiver operating characteristic curve. In both cases, the main problem for developing appropriate estimators is the estimation of the joint distribution of the variables time-to-event and marker. As usual, different approximations lead to different estimators. In this article, the authors explore the use of a bivariate kernel density estimator which accounts for censored observations in the sample and produces smooth estimators of the time-dependent receiver operating characteristic curves. The performance of the resulting cumulative/dynamic and incident/dynamic receiver operating characteristic curves is studied by means of Monte Carlo simulations. Additionally, the influence of the choice of the required smoothing parameters is explored. Finally, two real-applications are considered. An R package is also provided as a complement to this article.

  15. On Real-Time Operating Systems.

    Science.gov (United States)

    1987-04-01

    1Ri2 193 ONREAL-TIME OPERATING SYS EMS(U MAYLAN UN V COLLG PARK DEPT OF COMPUTER SCIENCE S LEVI ET AL APR 87 CS-TR-1838 NOSO14-87-K-9124 UNCLASSIFIED...and processes. In each instance the abstraction takes the form of some non- physical resource and benefits both the system and the user. ...The...service, which is important as an inter-process service (for physical synchronization) as well as an internal service for a process. A time service in a

  16. Speckle noise reduction in breast ultrasound images: SMU (srad median unsharp) approch

    International Nuclear Information System (INIS)

    Njeh, I.; Sassi, O. B.; Ben Hamida, A.; Chtourou, K.

    2011-01-01

    Image denoising has become a very essential for better information extraction from the image and mainly from so noised ones, such as ultrasound images. In certain cases, for instance in ultrasound images, the noise can restrain information which is valuable for the general practitioner. Consequently medical images are very inconsistent, and it is crucial to operate case to case. This paper presents a novel algorithm SMU (Srad Median Unsharp) for noise suppression in ultrasound breast images in order to realize a computer aided diagnosis (CAD) for breast cancer.

  17. Surgical team turnover and operative time: An evaluation of operating room efficiency during pulmonary resection.

    Science.gov (United States)

    Azzi, Alain Joe; Shah, Karan; Seely, Andrew; Villeneuve, James Patrick; Sundaresan, Sudhir R; Shamji, Farid M; Maziak, Donna E; Gilbert, Sebastien

    2016-05-01

    Health care resources are costly and should be used judiciously and efficiently. Predicting the duration of surgical procedures is key to optimizing operating room resources. Our objective was to identify factors influencing operative time, particularly surgical team turnover. We performed a single-institution, retrospective review of lobectomy operations. Univariate and multivariate analyses were performed to evaluate the impact of different factors on surgical time (skin-to-skin) and total procedure time. Staff turnover within the nursing component of the surgical team was defined as the number of instances any nurse had to leave the operating room over the total number of nurses involved in the operation. A total of 235 lobectomies were performed by 5 surgeons, most commonly for lung cancer (95%). On multivariate analysis, percent forced expiratory volume in 1 second, surgical approach, and lesion size had a significant effect on surgical time. Nursing turnover was associated with a significant increase in surgical time (53.7 minutes; 95% confidence interval, 6.4-101; P = .026) and total procedure time (83.2 minutes; 95% confidence interval, 30.1-136.2; P = .002). Active management of surgical team turnover may be an opportunity to improve operating room efficiency when the surgical team is engaged in a major pulmonary resection. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  18. Real-Time Operating Systems for Multicore Embedded Systems

    OpenAIRE

    Tomiyama, Hiroyuki; Honda, Shinya; Takada, Hiroaki

    2008-01-01

    Multicore systems-on-chip have become popular inthe design of embedded systems in order to simultaneously achieve high performance and low power consumption. On the software side, real-time operating systems are necessary in orderto handle growing complexity of embedded software. This paper describes requirements, design principles and implementation techniques for real-time operating systems to be used inasymmetric multicore systems.

  19. An Estimation of Operator's Diagnostic Time for Feed-And-Bleed Operation under Various Scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bo Gyung; Kang, Hyun Gook [KAIST, Daejeon (Korea, Republic of); Yoon, Ho Joon [Khalifa University of Science, Abu Dhabi (United Arab Emirates)

    2015-10-15

    In order to assess realistic safety of plant, effects of interactions between components, operator, and plant condition are needed to be considered in the PSA model. One of the important issues to estimate the CDF is the estimation of human error probability (HEP). When an accident occurs, operators follow the emergency operating procedure and check various alarm, parameters, and signals. In the conventional Korean PSA model, the Korean standard HRA (K-HRA) method is used. In this method, the HEP is the sum of diagnosis error probability and execution error probability. A diagnosis error probability is expressed by the available time for diagnosis and adjusting performance shaping factors, and an execution error probability is a function of task type and stress level. Available time for diagnosis is very important factor of HEP. If the available time for diagnosis is short, the HEP becomes high. In order to obtain the realistic risk assessment results, we first focus on the estimation of HEP considering the plant dynamics under various scenarios. Target operation and scenarios are feed-and bleed operation (F and B operation) and total loss of feedwater (TLOFW) accident with/without loss of coolant accident (LOCA). One of the highest HEP is HEP of FnB operation. In additional, Scenarios, which are related to combination secondary heat removal failure and primary heat removal failure, are most critical core damage scenario of the combined accident except scenarios related to station black out (SBO). In these scenarios, the FnB operation is last resort to prevent core damage. To estimate available operator diagnosis time, we identify the relationship between accidents, mitigation function, and plant condition. Distribution of available time of diagnosis was estimated using the MOSAIQUE. The variables are break size, break timing, trip timing of RCP, and availability of high pressure safety injection (HPSI) pump under the TLOFW accident with LOCA. For Type 1 accident

  20. Overview of real-time operating systems on microprocessor platforms

    International Nuclear Information System (INIS)

    Luong, T.T.

    1994-01-01

    This paper attempts to overview the real-time operating systems on microprocessor platforms in the field of experimental physics facility controls. The key issues regarding operating systems as well as standards and development environment are discussed. As an illustration, some current industrial products are indicated. Also, real-time systems operating in some institutes of the EPS/EPCS inter divisional group are reviewed. (author). 3 refs., 4 figs

  1. A distributed real-time operating system

    International Nuclear Information System (INIS)

    Tuynman, F.; Hertzberger, L.O.

    1984-07-01

    A distributed real-time operating system, Fados, has been developed for an embedded multi-processor system. The operating system is based on a host target approach and provides for communication between arbitrary processes on host and target machine. The facilities offered are, apart from process communication, access to the file system on the host by programs on the target machine and monitoring and debugging of programs on the target machine from the host. The process communication has been designed in such a way that the possibilities are the same as those offered by the Ada programming language. The operating system is implemented on a MC 68000 based multiprocessor system in combination with a Unix host. (orig.)

  2. Regularization of DT-MRI Using 3D Median Filtering Methods

    Directory of Open Access Journals (Sweden)

    Soondong Kwon

    2014-01-01

    Full Text Available DT-MRI (diffusion tensor magnetic resonance imaging tractography is a method to determine the architecture of axonal fibers in the central nervous system by computing the direction of the principal eigenvectors obtained from tensor matrix, which is different from the conventional isotropic MRI. Tractography based on DT-MRI is known to need many computations and is highly sensitive to noise. Hence, adequate regularization methods, such as image processing techniques, are in demand. Among many regularization methods we are interested in the median filtering method. In this paper, we extended two-dimensional median filters already developed to three-dimensional median filters. We compared four median filtering methods which are two-dimensional simple median method (SM2D, two-dimensional successive Fermat method (SF2D, three-dimensional simple median method (SM3D, and three-dimensional successive Fermat method (SF3D. Three kinds of synthetic data with different altitude angles from axial slices and one kind of human data from MR scanner are considered for numerical implementation by the four filtering methods.

  3. Safety performance evaluation of cable median barriers on freeways in Florida.

    Science.gov (United States)

    Alluri, Priyanka; Haleem, Kirolos; Gan, Albert; Mauthner, John

    2016-07-03

    This article aims to evaluate the safety performance of cable median barriers on freeways in Florida. The safety performance evaluation was based on the percentages of barrier and median crossovers by vehicle type, crash severity, and cable median barrier type (Trinity Cable Safety System [CASS] and Gibraltar system). Twenty-three locations with cable median barriers totaling about 101 miles were identified. Police reports of 6,524 crashes from years 2005-2010 at these locations were reviewed to verify and obtain detailed crash information. A total of 549 crashes were determined to be barrier related (i.e., crashes involving vehicles hitting the cable median barrier) and were reviewed in further detail to identify crossover crashes and the manner in which the vehicles crossed the barriers; that is, by either overriding, underriding, or penetrating the barriers. Overall, 2.6% of vehicles that hit the cable median barrier crossed the median and traversed into the opposite travel lane. Overall, 98.1% of cars and 95.5% of light trucks that hit the barrier were prevented from crossing the median. In other words, 1.9% of cars and 4.5% of light trucks that hit the barrier had crossed the median and encroached on the opposite travel lanes. There is no significant difference in the performance of cable median barrier for cars versus light trucks in terms of crossover crashes. In terms of severity, overrides were more severe compared to underrides and penetrations. The statistics showed that the CASS and Gibraltar systems performed similarly in terms of crossover crashes. However, the Gibraltar system experienced a higher proportion of penetrations compared to the CASS system. The CASS system resulted in a slightly higher percentage of moderate and minor injury crashes compared to the Gibraltar system. Cable median barriers are successful in preventing median crossover crashes; 97.4% of the cable median barrier crashes were prevented from crossing over the median. Of all of

  4. Performance evaluation of cable median barrier systems in Texas.

    Science.gov (United States)

    2009-08-01

    Since 2003, the Texas Department of Transportation (TxDOT) has embarked on an aggressive campaign to install : median barriers to prevent cross-median crashes on freeway facilities statewide. In the few years prior to 2003, : virtually all fatalities...

  5. Research and application of embedded real-time operating system

    Science.gov (United States)

    Zhang, Bo

    2013-03-01

    In this paper, based on the analysis of existing embedded real-time operating system, the architecture of an operating system is designed and implemented. The experimental results show that the design fully complies with the requirements of embedded real-time operating system, can achieve the purposes of reducing the complexity of embedded software design and improving the maintainability, reliability, flexibility. Therefore, this design program has high practical value.

  6. Simulation-based multidisciplinary team training decreases time to critical operations for trauma patients.

    Science.gov (United States)

    Murphy, Margaret; Curtis, Kate; Lam, Mary K; Palmer, Cameron S; Hsu, Jeremy; McCloughen, Andrea

    2018-05-01

    Simulation has been promoted as a platform for training trauma teams. However, it is not clear if this training has an impact on health service delivery and patient outcomes. This study evaluates the association between implementation of a simulation based multidisciplinary trauma team training program at a metropolitan trauma centre and subsequent patient outcomes. This was a retrospective review of trauma registry data collected at an 850-bed Level 1 Adult Trauma Centre in Sydney, Australia. Two concurrent four-year periods, before and after implementation of a simulation based multidisciplinary trauma team training program were compared for differences in time to critical operations, Emergency Department (ED) length of stay (LOS) and patient mortality. There were 2389 major trauma patients admitted to the hospital during the study, 1116 in the four years preceding trauma team training (the PREgroup) and 1273 in the subsequent 4 years (the POST group). There were no differences between the groups with respect to gender, body region injured, incidence of polytrauma, and pattern of arrival to ED. The POST group was older (median age 54 versus 43 years, p team training was associated with a reduction in time to critical operation while overall ED length of stay increased. Simulation is promoted as a platform for training teams; but the complexity of trauma care challenges efforts to demonstrate direct links between multidisciplinary team training and improved outcomes. There remain considerable gaps in knowledge as to how team training impacts health service delivery and patient outcomes. Retrospective comparative therapeutic/care management study, Level III evidence. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  7. Study of recurrent branch of median nerve (Thenar's muscular branch in relation to the flexor retinaculum and median in 64 hands (32 Men

    Directory of Open Access Journals (Sweden)

    Amirsadri R

    1998-07-01

    Full Text Available Variation of recurred branch of median nerve in relation to the median and flexor retinaculum are significant for both hand surgeons and specialists always. In this study, 64 cadaver hands (32 men have been dissected. The median nerve was identified at the proximal edge of the flexor retinaculum, and in order to expose carpal tunnel the ligament was divided, and the above subjects were studied. The results are: 1 The relation of recurrent nerve to the flexor retinaculum was classified into 4 types: A In (53.1% of subjects, this branch arises from the median after the flexor retinaculum. B In (31.3% of subjects, it arises from the median in the carpal tunnel and the moves around the lower edge of flexor retinaculum and enters the thenar region. C In (14.1% of subjects, it arises from the median in the carpal tunnel and pierces the flexor retinaculum. D In (1.56% of subjects it arises, in the carpal tunnel and it divides into two subbranches here. One follows pattern A and the other pattern C. 2 In this step, the relation of the recurrent branch to the median nerve was studied. The results show that inspite of this image even though most often the recurrent branch arises from the lateral side of median, in (68.75% of subjects it arises from it's anterior surface. The MC Nemar test reveals that there is no relation between manifestation of mentioned patterns with right or left hands.

  8. Endoscopic stenting versus operative gastrojejunostomy for malignant gastric outlet obstruction.

    Science.gov (United States)

    Chandrasegaram, Manju D; Eslick, Guy D; Mansfield, Clare O; Liem, Han; Richardson, Mark; Ahmed, Sulman; Cox, Michael R

    2012-02-01

    Malignant gastric outlet obstruction represents a terminal stage in pancreatic cancer. Between 5% and 25% of patients with pancreatic cancer ultimately experience malignant gastric outlet obstruction. The aim in palliating patients with malignant gastric outlet obstruction is to reestablish an oral intake by restoring gastrointestinal continuity. This ultimately improves their quality of life in the advanced stages of cancer. The main drawback to operative bypass is the high incidence of delayed gastric emptying, particularly in this group of patients with symptomatic obstruction. This study aimed to compare surgical gastrojejunostomy and endoscopic stenting in palliation of malignant gastric outlet obstruction, acknowledging the diversity and heterogeneity of patients with this presentation. This retrospective study investigated patients treated for malignant gastric outlet obstruction from December 1998 to November 2008 at Nepean Hospital, Sydney, Australia. Endoscopic duodenal stenting was performed under fluoroscopic guidance for placement of the stent. The operative patients underwent open surgical gastrojejunostomy. The outcomes assessed included time to diet, hospital length of stay (LOS), biliary drainage procedures, morbidity, and mortality. Of the 45 participants in this study, 26 underwent duodenal stenting and 19 had operative bypass. Comparing the stenting and operative patients, the median time to fluid intake was respectively 0 vs. 7 days (P < 0.001), and the time to intake of solids was 2 vs. 9 days (P = 0.004). The median total LOS was shorter in the stenting group (11 vs. 25 days; P < 0.001), as was the median postprocedure LOS (5 vs. 10 days; P = 0.07). Endoscopic stenting is preferable to operative gastrojejunostomy in terms of shorter LOS, faster return to fluids and solids, and reduced morbidity and in-hospital mortality for patients with a limited life span.

  9. Seeking for the rational basis of the Median Model: the optimal combination of multi-model ensemble results

    Directory of Open Access Journals (Sweden)

    A. Riccio

    2007-12-01

    Full Text Available In this paper we present an approach for the statistical analysis of multi-model ensemble results. The models considered here are operational long-range transport and dispersion models, also used for the real-time simulation of pollutant dispersion or the accidental release of radioactive nuclides.

    We first introduce the theoretical basis (with its roots sinking into the Bayes theorem and then apply this approach to the analysis of model results obtained during the ETEX-1 exercise. We recover some interesting results, supporting the heuristic approach called "median model", originally introduced in Galmarini et al. (2004a, b.

    This approach also provides a way to systematically reduce (and quantify model uncertainties, thus supporting the decision-making process and/or regulatory-purpose activities in a very effective manner.

  10. Embedded and real-time operating systems

    CERN Document Server

    Wang, K C

    2017-01-01

    This book covers the basic concepts and principles of operating systems, showing how to apply them to the design and implementation of complete operating systems for embedded and real-time systems. It includes all the foundational and background information on ARM architecture, ARM instructions and programming, toolchain for developing programs, virtual machines for software implementation and testing, program execution image, function call conventions, run-time stack usage and link C programs with assembly code. It describes the design and implementation of a complete OS for embedded systems in incremental steps, explaining the design principles and implementation techniques. For Symmetric Multiprocessing (SMP) embedded systems, the author examines the ARM MPcore processors, which include the SCU and GIC for interrupts routing and interprocessor communication and synchronization by Software Generated Interrupts (SGIs). Throughout the book, complete working sample systems demonstrate the design principles and...

  11. A theoretical analysis of the median LMF adaptive algorithm

    DEFF Research Database (Denmark)

    Bysted, Tommy Kristensen; Rusu, C.

    1999-01-01

    Higher order adaptive algorithms are sensitive to impulse interference. In the case of the LMF (Least Mean Fourth), an easy and effective way to reduce this is to median filter the instantaneous gradient of the LMF algorithm. Although previous published simulations have indicated that this reduces...... the speed of convergence, no analytical studies have yet been made to prove this. In order to enhance the usability, this paper presents a convergence and steady-state analysis of the median LMF adaptive algorithm. As expected this proves that the median LMF has a slower convergence and a lower steady...

  12. Advanced Hard Real-Time Operating System, the Maruti Project. Part 2.

    Science.gov (United States)

    1997-01-01

    Real - Time Operating System , The Maruti Project DASG-60-92-C-0055 5b. Program Element # 62301E 6. Author(s...The maruti hard real - time " operating system . A CM SIGOPS, Operating Systems Review. 23:90-106, July 1989. 254 !1 110) C. L. Liu and J. Layland...February 14, 1995 Abstract The Maruti Real - Time Operating System was developed for applications that must meet hard real-time constraints. In order

  13. Natural world physical, brain operational, and mind phenomenal space-time

    Science.gov (United States)

    Fingelkurts, Andrew A.; Fingelkurts, Alexander A.; Neves, Carlos F. H.

    2010-06-01

    Concepts of space and time are widely developed in physics. However, there is a considerable lack of biologically plausible theoretical frameworks that can demonstrate how space and time dimensions are implemented in the activity of the most complex life-system - the brain with a mind. Brain activity is organized both temporally and spatially, thus representing space-time in the brain. Critical analysis of recent research on the space-time organization of the brain's activity pointed to the existence of so-called operational space-time in the brain. This space-time is limited to the execution of brain operations of differing complexity. During each such brain operation a particular short-term spatio-temporal pattern of integrated activity of different brain areas emerges within related operational space-time. At the same time, to have a fully functional human brain one needs to have a subjective mental experience. Current research on the subjective mental experience offers detailed analysis of space-time organization of the mind. According to this research, subjective mental experience (subjective virtual world) has definitive spatial and temporal properties similar to many physical phenomena. Based on systematic review of the propositions and tenets of brain and mind space-time descriptions, our aim in this review essay is to explore the relations between the two. To be precise, we would like to discuss the hypothesis that via the brain operational space-time the mind subjective space-time is connected to otherwise distant physical space-time reality.

  14. Real time operation of a multiple gamma measurement installation

    International Nuclear Information System (INIS)

    Philippot, J.C.; Lefevre, J.

    1980-01-01

    This paper describes a multiple measurement channel facility for fine gamma spectrometry, its real time operation, and the new possibilities which it offers. The installation is presented in its twofold electronic and processing aspects, by considering its architecture, its hard and software, and its data processing package. Real time operation requires customized general organization, perfect instantaneous knowledge of the status of all the units, and a sound hierarchy between the various participants, operators as well as requestors. The care inherent in the installation itself and in the definition of its operation explains its new possibilities. (Auth.)

  15. Uncommon Dorsal Radiocarpal Fracture Dislocation Complicated With Median Nerve Palsy: Case Report, Review of the Literature, and a New Classification System Guiding the Management

    Directory of Open Access Journals (Sweden)

    Hing-Cheong Wong

    2012-06-01

    Full Text Available We report the case of a 36-year-old lorry driver who sustained left dorsal radiocarpal fracture dislocation and left median nerve injury in a traffic accident in 2010. Emergency operation of closed reduction, cross-wrist-bridging external fixation, percutaneous transradial styloid Kirschner wire fixation, decompression of left median nerve, and repair of the partially torn palmar radiocarpal ligament were performed under general anaesthesia. Because of the persistent depressed dorsal articular rim fracture of left distal radius, another operation of open reduction, corticocancellous bone grafting, and dorsal buttress plating was performed 5 days after the initial operation. Six months after the operation, the patient enjoyed good range of wrist motion but weak twisting power, especially in supination. There was no radiological feature of radiocarpal subluxation.

  16. The Investigation of Median Frequency Changes in Paraspinal Muscles Following Fatigue

    Directory of Open Access Journals (Sweden)

    Saeed Talebian

    2009-10-01

    Conclusion: Median frequency shift toward low values following fatigue in global and local paraspinal muscles was seen. However, median frequency values for the local stabilizer muscle were higher than median frequency values for the global muscles.

  17. Premedication with gabapentin, alprazolam or a placebo for abdominal hysterectomy: Effect on pre-operative anxiety, post-operative pain and morphine consumption

    Directory of Open Access Journals (Sweden)

    Tim Thomas Joseph

    2014-01-01

    Full Text Available Background and Aims : Utility of gabapentin for pre-operative anxiolysis as compared to commonly administered alprazolam is not evident. The aim of the present study was to compare the effects of pre-operative oral gabapentin 600 mg, alprazolam 0.5 mg or a placebo on pre-operative anxiety along with post-operative pain and morphine consumption. Methods: Seventy five patients scheduled for abdominal hysterectomy under general anaesthesia were included. Groups gabapentin, alprazolam and placebo, received oral gabapentin 600 mg, alprazolam 0.5 mg and one capsule of oral B-complex forte with Vitamin C respectively, on the night prior to surgery and 2 h prior to surgery. Visual analogue scale (VAS was used to measure the anxiety and post-operative pain. All patients received patient-controlled analgesia. Statistical tests used were Kruskal-Wallis test, Wilcoxon signed rank test and one-way ANOVA. Results: Alprazolam provided significant anxiolysis (median [interquartile range] baseline VAS score 35 [15.5, 52] to 20 [6.5, 34.5] after drug administration; P = 0.007. Gabapentin did not provide significant decrease in anxiety (median [interquartile range] VAS score 21 [7.5, 41] to 20 [6.5, 34.5]; P = 0.782. First analgesic request time (median [interquartile range in minutes] was longer in group gabapentin (17.5 [10, 41.25] compared to group placebo (10 [5, 15] (P = 0.019 but comparable to that in group alprazolam (15 [10, 30]. Cumulative morphine consumption at different time periods and total morphine consumption (mean [standard deviation] at the end of study period (38.65 [18.04], 39.91 [15.73], 44.29 [16.02] mg in group gabapentin, alprazolam and placebo respectively were comparable. Conclusion: Gabapentin 600 mg does not have significant anxiolytic effect compared to alprazolam 0.5 mg. Alprazolam 0.5 mg was found to be an effective anxiolytic in the pre-operative period. Neither alprazolam nor gabapentin, when compared to placebo showed any opioid

  18. Intraneural synovial sarcoma of the median nerve

    Directory of Open Access Journals (Sweden)

    Rahul Kasukurthi

    2010-06-01

    Full Text Available Synovial sarcomas are soft-tissue malignancies with a poor prognosis and propensity for distant metastases. Although originally believed to arise from the synovium, these tumors have been found to occur anywhere in the body. We report a rare case of synovial sarcoma arising from the median nerve. To our knowledge, this is the twelfth reported case of intraneural synovial sarcoma, and only the fourth arising from the median nerve. Because the diagnosis may not be apparent until after pathological examination of the surgical speci­men, synovial sarcoma should be kept in mind when dealing with what may seem like a benign nerve tumor.

  19. Mixed-mode Operating System for Real-time Performance

    Directory of Open Access Journals (Sweden)

    M.M. Hasan

    2017-11-01

    Full Text Available The purpose of the mixed-mode system research is to handle devices with the accuracy of real-time systems and at the same time, having all the benefits and facilities of a matured Graphic User Interface (GUI operating system which is typically nonreal-time. This mixed-mode operating system comprising of a real-time portion and a non-real-time portion was studied and implemented to identify the feasibilities and performances in practical applications (in the context of scheduled the real-time events. In this research an i8751 microcontroller-based hardware was used to measure the performance of the system in real-time-only as well as non-real-time-only configurations. The real-time portion is an 486DX-40 IBM PC system running under DOS-based realtime kernel and the non-real-time portion is a Pentium III based system running under Windows NT. It was found that mixed-mode systems performed as good as a typical realtime system and in fact, gave many additional benefits such as simplified/modular programming and load tolerance.

  20. Prolonged operative time increases infection rate in tibial plateau fractures.

    Science.gov (United States)

    Colman, Matthew; Wright, Adam; Gruen, Gary; Siska, Peter; Pape, Hans-Christoph; Tarkin, Ivan

    2013-02-01

    Fractures of the tibial plateau present a treatment challenge and are susceptible to both prolonged operative times and high postoperative infection rates. For those fractures treated with open plating, we sought to identify the relationship between surgical site infection and prolonged operative time as well as to identify other surgical risk factors. We performed a retrospective controlled analysis of 309 consecutive unicondylar and bicondylar tibial plateau fractures treated with open plate osteosynthesis at our institution's level I trauma centre during a recent 5-year period. We recorded operative times, injury characteristics, surgical treatment, and need for operative debridement due to infection. Operative times of infected cases were compared to uncomplicated surgical cases. Multivariable logistic regression analysis was performed to identify independent risk factors for postoperative infection. Mean operative time in the infection group was 2.8h vs. 2.2h in the non-infected group (p=0.005). 15 fractures (4.9%) underwent four compartment fasciotomies as part of their treatment, with a significantly higher infection rate than those not undergoing fasciotomy (26.7% vs. 6.8%, p=0.01). Open fracture grade was also significantly related to infection rate (closed fractures: 5.3%, grade 1: 14.3%, grade 2: 40%, grade 3: 50%, pinfection rates (13.9% vs. 8.7%, p=0.36). Multivariable logistic regression analysis of the entire study group identified longer operative times (OR 1.78, p=0.013) and open fractures (OR 7.02, psite infection. Operative times approaching 3h and open fractures are related to an increased overall risk for surgical site infection after open plating of the tibial plateau. Dual incision approaches with bicolumnar plating do not appear to expose the patient to increased risk compared to single incision approaches. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Robust K-Median and K-Means Clustering Algorithms for Incomplete Data

    Directory of Open Access Journals (Sweden)

    Jinhua Li

    2016-01-01

    Full Text Available Incomplete data with missing feature values are prevalent in clustering problems. Traditional clustering methods first estimate the missing values by imputation and then apply the classical clustering algorithms for complete data, such as K-median and K-means. However, in practice, it is often hard to obtain accurate estimation of the missing values, which deteriorates the performance of clustering. To enhance the robustness of clustering algorithms, this paper represents the missing values by interval data and introduces the concept of robust cluster objective function. A minimax robust optimization (RO formulation is presented to provide clustering results, which are insensitive to estimation errors. To solve the proposed RO problem, we propose robust K-median and K-means clustering algorithms with low time and space complexity. Comparisons and analysis of experimental results on both artificially generated and real-world incomplete data sets validate the robustness and effectiveness of the proposed algorithms.

  2. REAL TIME SYSTEM OPERATIONS 2006-2007

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joseph H.; Parashar, Manu; Lewis, Nancy Jo

    2008-08-15

    The Real Time System Operations (RTSO) 2006-2007 project focused on two parallel technical tasks: (1) Real-Time Applications of Phasors for Monitoring, Alarming and Control; and (2) Real-Time Voltage Security Assessment (RTVSA) Prototype Tool. The overall goal of the phasor applications project was to accelerate adoption and foster greater use of new, more accurate, time-synchronized phasor measurements by conducting research and prototyping applications on California ISO's phasor platform - Real-Time Dynamics Monitoring System (RTDMS) -- that provide previously unavailable information on the dynamic stability of the grid. Feasibility assessment studies were conducted on potential application of this technology for small-signal stability monitoring, validating/improving existing stability nomograms, conducting frequency response analysis, and obtaining real-time sensitivity information on key metrics to assess grid stress. Based on study findings, prototype applications for real-time visualization and alarming, small-signal stability monitoring, measurement based sensitivity analysis and frequency response assessment were developed, factory- and field-tested at the California ISO and at BPA. The goal of the RTVSA project was to provide California ISO with a prototype voltage security assessment tool that runs in real time within California ISO?s new reliability and congestion management system. CERTS conducted a technical assessment of appropriate algorithms, developed a prototype incorporating state-of-art algorithms (such as the continuation power flow, direct method, boundary orbiting method, and hyperplanes) into a framework most suitable for an operations environment. Based on study findings, a functional specification was prepared, which the California ISO has since used to procure a production-quality tool that is now a part of a suite of advanced computational tools that is used by California ISO for reliability and congestion management.

  3. Application of total care time and payment per unit time model for physician reimbursement for common general surgery operations.

    Science.gov (United States)

    Chatterjee, Abhishek; Holubar, Stefan D; Figy, Sean; Chen, Lilian; Montagne, Shirley A; Rosen, Joseph M; Desimone, Joseph P

    2012-06-01

    The relative value unit system relies on subjective measures of physician input in the care of patients. A payment per unit time model incorporates surgeon reimbursement to the total care time spent in the operating room, postoperative in-house, and clinic time to define payment per unit time. We aimed to compare common general surgery operations by using the total care time and payment per unit time method in order to demonstrate a more objective measurement for physician reimbursement. Average total physician payment per case was obtained for 5 outpatient operations and 4 inpatient operations in general surgery. Total care time was defined as the sum of operative time, 30 minutes per hospital day, and 30 minutes per office visit for each operation. Payment per unit time was calculated by dividing the physician reimbursement per case by the total care time. Total care time, physician payment per case, and payment per unit time for each type of operation demonstrated that an average payment per time spent for inpatient operations was $455.73 and slightly more at $467.51 for outpatient operations. Partial colectomy with primary anastomosis had the longest total care time (8.98 hours) and the least payment per unit time ($188.52). Laparoscopic gastric bypass had the highest payment per time ($707.30). The total care time and payment per unit time method can be used as an adjunct to compare reimbursement among different operations on an institutional level as well as on a national level. Although many operations have similar payment trends based on time spent by the surgeon, payment differences using this methodology are seen and may be in need of further review. Copyright © 2012 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Median and ulnar neuropathies in U.S. Army Medical Command Band members.

    Science.gov (United States)

    Shaffer, Scott W; Koreerat, Nicholas R; Gordon, Lindsay B; Santillo, Douglas R; Moore, Josef H; Greathouse, David G

    2013-12-01

    Musicians have been reported as having a high prevalence of upper-extremity musculoskeletal disorders, including carpal tunnel syndrome. The purpose of this study was to determine the presence of median and ulnar neuropathies in U.S. Army Medical Command (MEDCOM) Band members at Fort Sam Houston, Texas. Thirty-five MEDCOM Band members (30 males, 5 females) volunteered to participate. There were 33 right-handed musicians, and the mean length of time in the MEDCOM Band was 12.2 yrs (range, 1-30 yrs). Subjects completed a history form, were interviewed, and underwent a physical examination of the cervical spine and bilateral upper extremities. Nerve conduction studies of the bilateral median and ulnar nerves were performed. Electrophysiological variables served as the reference standard for median and ulnar neuropathy and included distal sensory latencies, distal motor latencies, amplitudes, conduction velocities, and comparison study latencies. Ten of the 35 subjects (29%) presented with abnormal electrophysiologic values suggestive of an upper extremity mononeuropathy. Nine of the subjects had abnormal median nerve electrophysiologic values at or distal to the wrist; 2 had bilateral abnormal values. One had an abnormal ulnar nerve electrophysiologic assessment at the elbow. Nine of these 10 subjects had clinical examination findings consistent with the electrophysiological findings. The prevalence of mononeuropathies in this sample of band members is similar to that found in previous research involving civilian musicians (20-36%) and far exceeds that reported in the general population. Prospective research investigating screening, examination items, and injury prevention measures in musicians appears to be warranted.

  5. Relationship between laparoscopic cholecystectomy operative time and carbonyl hemoglobin content

    Directory of Open Access Journals (Sweden)

    ZHANG Qi

    2013-06-01

    Full Text Available ObjectiveTo investigate whether operative time of laparoscopic cholecystectomy impacts the carbonyl hemoglobin (COHb concentration in peripheral blood. MethodsForty patients with gallstones and indications for laparoscopic cholecystectomy were enrolled in the study. Peripheral venous blood samples were collected at the beginning and end of the operative procedure. COHb concentration was measured by UV spectroscopy. The significance of changes in COHb concentration in relation to time of the operative procedure (rounded to the nearest minute was assessed by statistical correlation coefficient test. ResultsThe laparoscopic procedure was completed in 38 cases, and two patients required conversion to laparotomy. The content of COHb in peripheral venous blood had significantly increased during the laparoscopic operation (operation beginning: 11.07%±1.18% vs. operation end: 1.44%±0.26%, P<0.05. The change was positively correlated with operation time (r=0.85. ConclusionCarbon monoxide produced during the laparoscopic cholecystectomy procedure can lead to an increase in peripheral venous blood COHb. The longer the operation lasts, the greater the increase in COHb.

  6. Effect of Streamflow Forecast Uncertainty on Real-Time Reservoir Operation

    Science.gov (United States)

    Zhao, T.; Cai, X.; Yang, D.

    2010-12-01

    Various hydrological forecast products have been applied to real-time reservoir operation, including deterministic streamflow forecast (DSF), DSF-based probabilistic streamflow forecast (DPSF), and ensemble streamflow forecast (ESF), which represent forecast uncertainty in the form of deterministic forecast error, deterministic forecast error-based uncertainty distribution, and ensemble forecast errors, respectively. Compared to previous studies that treat these forecast products as ad hoc inputs for reservoir operation models, this paper attempts to model the uncertainties involved in the various forecast products and explores their effect on real-time reservoir operation decisions. In hydrology, there are various indices reflecting the magnitude of streamflow forecast uncertainty; meanwhile, few models illustrate the forecast uncertainty evolution process. This research introduces Martingale Model of Forecast Evolution (MMFE) from supply chain management and justifies its assumptions for quantifying the evolution of uncertainty in streamflow forecast as time progresses. Based on MMFE, this research simulates the evolution of forecast uncertainty in DSF, DPSF, and ESF, and applies the reservoir operation models (dynamic programming, DP; stochastic dynamic programming, SDP; and standard operation policy, SOP) to assess the effect of different forms of forecast uncertainty on real-time reservoir operation. Through a hypothetical single-objective real-time reservoir operation model, the results illustrate that forecast uncertainty exerts significant effects. Reservoir operation efficiency, as measured by a utility function, decreases as the forecast uncertainty increases. Meanwhile, these effects also depend on the type of forecast product being used. In general, the utility of reservoir operation with ESF is nearly as high as the utility obtained with a perfect forecast; the utilities of DSF and DPSF are similar to each other but not as efficient as ESF. Moreover

  7. Minimally invasive repair of pectus excavatum in an adolescent with a history of a median sternotomy as an infant

    Directory of Open Access Journals (Sweden)

    Lauren Huckaby

    2014-10-01

    Full Text Available The report by Nuss et al., in 1998 of their 10-year experience with minimally invasive repair of pectus excavatum introduced the possibility of a less invasive approach for the correction of chest wall abnormalities. This procedure is now well-accepted around the world, although serious complications such as intraoperative cardiac perforation and postoperative bar displacement have been reported. The Nuss procedure has been performed concurrently with sternotomy for cardiac operations. However, there have been no reports of minimally invasive pectus excavatum correction in a child with a remote history of a median sternotomy. With IRB approval (Protocol #1308002283 we report the successful completion of a Nuss procedure in an adolescent with a history of a median sternotomy in infancy. During the procedure, thoracoscopy on the right side revealed significant adhesions of the lung and pericardium to the posterior sternum. Additional trocars were placed bilaterally to facilitate visualization and to allow for lysis of the adhesions with bipolar cautery. Passage of the bar was accomplished uneventfully and the patient has an excellent cosmetic outcome 28 months following the operation. We believe that a previous median sternotomy should not be viewed as a contraindication to the minimally invasive repair of pectus excavatum.

  8. Nursing Leaders' Satisfaction with Information Systems in the Day-to-Day Operations Management in Hospital Units.

    Science.gov (United States)

    Peltonen, Laura-Maria; Junttila, Kristiina; Salanterä, Sanna

    2018-01-01

    Information usage in the day-to-day operations management of hospital units is complex due to numerous information systems in use. The aim of this study was to describe and compare nurse leaders' satisfaction with information systems used in the day-to-day operations management in hospital units. The design was a cross-sectional survey with five questions rated from one (disagree) to five (fully agree). The response rate was 65 % (n = 453). Respondents reported fair satisfaction with how information systems support decision-making (median 4, IQR 3-4) and improve ease of access to information (median 4, IQR 3-4). However, respondents were less satisfied with how systems improve speed of access to information (median 3, IQR 3-4). Nor did respondents think that systems were developed for them (median 3, IQR 2-4). Respondents further reported needing numerous systems daily to support decision-making (median 4, IQR 3-5). A clear need for one system, which would gather important information for display was stated (median 5, IQR 4-5). Work experience, gender and time when overseeing the unit were associated with some aspects related to satisfaction. In conclusion, information system improvements are needed to better support the day-to-day operations management in hospital units.

  9. Cold intolerance following median and ulnar nerve injuries : prognosis and predictors

    NARCIS (Netherlands)

    Ruijs, A.C.J; Jaquet, J-B.; van Riel, W. G.; Daanen, H. A M; Hovius, S.E.R.

    This study describes the predictors for cold intolerance and the relationship to sensory recovery after median and ulnar nerve injuries. The study population consisted of 107 patients 2 to 10 years after median, ulnar or combined median and ulnar nerve injuries. Patients were asked to fill out the

  10. Cold intolerance following median and ulnar nerve injuries : prognosis and predictors

    NARCIS (Netherlands)

    Ruijs, A.C.J.; Jaquet, J.B.; Riel, W.G. van; Daanen, H.A.M.; Hovius, S.E.R.

    2007-01-01

    This study describes the predictors for cold intolerance and the relationship to sensory recovery after median and ulnar nerve injuries. The study population consisted of 107 patients 2 to 10 years after median, ulnar or combined median and ulnar nerve injuries. Patients were asked to fill out the

  11. Robust non-local median filter

    Science.gov (United States)

    Matsuoka, Jyohei; Koga, Takanori; Suetake, Noriaki; Uchino, Eiji

    2017-04-01

    This paper describes a novel image filter with superior performance on detail-preserving removal of random-valued impulse noise superimposed on natural gray-scale images. The non-local means filter is in the limelight as a way of Gaussian noise removal with superior performance on detail preservation. By referring the fundamental concept of the non-local means, we had proposed a non-local median filter as a specialized way for random-valued impulse noise removal so far. In the non-local processing, the output of a filter is calculated from pixels in blocks which are similar to the block centered at a pixel of interest. As a result, aggressive noise removal is conducted without destroying the detailed structures in an original image. However, the performance of non-local processing decreases enormously in the case of high noise occurrence probability. A cause of this problem is that the superimposed noise disturbs accurate calculation of the similarity between the blocks. To cope with this problem, we propose an improved non-local median filter which is robust to the high level of corruption by introducing a new similarity measure considering possibility of being the original signal. The effectiveness and validity of the proposed method are verified in a series of experiments using natural gray-scale images.

  12. Usefulness of ultrasound assessment of median nerve mobility in carpal tunnel syndrome.

    Science.gov (United States)

    Park, Gi-Young; Kwon, Dong Rak; Seok, Jung Im; Park, Dong-Soon; Cho, Hee Kyung

    2018-01-01

    Background Carpal tunnel syndrome (CTS) is the most common peripheral compression neuropathy of the upper extremity. Recently, dynamic ultrasound (US) imaging has shown differences in median nerve mobility between the affected and unaffected sides in CTS. Purpose The present study was performed to compare the median nerve mobility between patients with CTS and healthy individuals, and to correlate median nerve mobility with the severity of CTS. Material and Methods A total of 101 patients (128 wrists) with CTS and 43 healthy individuals (70 wrists) were evaluated. Electrodiagnostic studies were initially conducted to determine the neurophysiological grading scale (NGS). The cross-sectional area (CSA) of the median nerve and the grade of median nerve mobility were measured using US. Results The mean grade of median nerve mobility in the CTS group (1.9) was significantly lower than that in the control group (2.6; P mobility and distal motor latency of the median nerve (r = -0.218, P = 0.015), NGS (r = -0.207, P = 0.020) and CSA of the median nerve (r = -0.196, P = 0.028). Conclusion The grade of median nerve mobility was negatively correlated with the severity of CTS. US assessment of median nerve mobility may be useful in diagnosing and determining the severity of CTS.

  13. Wound infections after median sternotomy treated by VAC therapy, summary of results, and risk factor analysis.

    Science.gov (United States)

    Hulman, M; Bezak, B; Artemiou, P; Cikrai, R

    2017-01-01

    The aim of this study is to summarize results and analyze risk factors for the development of wound infection in heart surgery patients after median sternotomy. In this retrospective analysis with assessment of multiple risk factors, we examined 143 patients with infection after median sternotomy treated with VAC therapy from total of 4,650 patients operated in our department from 2012 to 2015. Total of 143 patients developed significant SSI treated by VAC therapy following cardiac surgery. Of these, only 14 patients developed DSWI and one patient was diagnosed with suspected osteomyelitis. BMI, female gender, and use of BIMA proved to be statistically significant risk factors in our study (p infection (p infection proved to be a significant prognostic factor for patients' outcome (p infection (Tab. 3, Ref. 30).

  14. Timing system for multi-bunch/multi-train operation at ATF

    International Nuclear Information System (INIS)

    Naito, T.; Hayano, H.; Urakawa, J.; Imai, T.

    2000-01-01

    A timing system has been constructed for multi-bunch/multi-train operation at KEK-ATF. The linac accelerates 20 bunches of multi-bunch with 2.8 ns spacing. The Damping Ring stores up to 5 trains of multi-bunch. The timing system is required to provide flexible operation mode and bucket selection. A personal computer is used for manipulating the timing. The performance of kicker magnets at the injection/extruction is key issue for multi-train operation. The hardware and the test results are presented. (author)

  15. Prediction of the time-dependent failure rate for normally operating components taking into account the operational history

    International Nuclear Information System (INIS)

    Vrbanic, I.; Simic, Z.; Sljivac, D.

    2008-01-01

    The prediction of the time-dependent failure rate has been studied, taking into account the operational history of a component used in applications such as system modeling in a probabilistic safety analysis in order to evaluate the impact of equipment aging and maintenance strategies on the risk measures considered. We have selected a time-dependent model for the failure rate which is based on the Weibull distribution and the principles of proportional age reduction by equipment overhauls. Estimation of the parameters that determine the failure rate is considered, including the definition of the operational history model and likelihood function for the Bayesian analysis of parameters for normally operating repairable components. The operational history is provided as a time axis with defined times of overhauls and failures. An example for demonstration is described with prediction of the future behavior for seven different operational histories. (orig.)

  16. Sosiaalisen median rooli kunnan viestinnässä

    OpenAIRE

    Selkämaa, Kati

    2016-01-01

    Opinnäytetyön tavoitteena oli selvittää sosiaalisen median roolia kunnan viestinnässä sekä tutkia, miten sosiaalista mediaa hyödynnetään kuntien viestinnässä. Teoriaosuudessa tarkasteltiin sosiaalista mediaa, tutustuttiin sen tunnetuimpiin sovelluksiin sekä perehdyttiin kuntien viestintään yleisesti. Työssä tarkasteltiin myös kuntien viestintään vaikuttavia ja sitä sääteleviä lakeja. Kuntien sosiaalisen median käyttöön tutustuttiin Kuntaliiton tekemän viestintätutkimuksen tulosten pohjalt...

  17. Development of guidelines for cable median barrier systems in Texas.

    Science.gov (United States)

    2009-12-01

    Since 2003, the Texas Department of Transportation (TxDOT) has embarked on an aggressive campaign to install : median barriers to prevent cross-median crashes on freeway facilities statewide. In the few years prior to 2003, : virtually all fatalities...

  18. A Real-Time Simulation Platform for Power System Operation

    DEFF Research Database (Denmark)

    Cha, Seung-Tae; Østergaard, Jacob; Wu, Qiuwei

    2010-01-01

    This paper describes the real-time digital simulation platform that can be used for power system operation, analysis, and power system modeling. This particular platform gives grid operators, planners and researchers the opportunity to observe how a power system behaves and can be used...... in real time. Various phenomena commonly encountered when dealing with the two-area system is studied. Despite its small size, it mimics very closely the behavior of typical systems in actual operation. The electromagnetic transient type of simulation made in RSCAD enables the study of fast and detailed...... phenomena like single-phase faults in the two-area network and to observe their effects on a larger time scale. Also, the case study of 11 bus system with 5 generators has been also used and the results are presented....

  19. Median nerve trauma in a rat model of work-related musculoskeletal disorder.

    Science.gov (United States)

    Clark, Brian D; Barr, Ann E; Safadi, Fayez F; Beitman, Lisa; Al-Shatti, Talal; Amin, Mamta; Gaughan, John P; Barbe, Mary F

    2003-07-01

    Anatomical and physiological changes were evaluated in the median nerves of rats trained to perform repetitive reaching. Motor degradation was evident after 4 weeks. ED1-immunoreactive macrophages were seen in the transcarpal region of the median nerve of both forelimbs by 5-6 weeks. Fibrosis, characterized by increased immunoexpression of collagen type I by 8 weeks and connective tissue growth factor by 12 weeks, was evident. The conduction velocity (NCV) within the carpal tunnel showed a modest but significant decline after 9-12 weeks. The lowest NCV values were found in animals that refused to participate in the task for the full time available. Thus, both anatomical and physiological signs of progressive tissue damage were present in this model. These results, together with other recent findings indicate that work-related carpal tunnel syndrome develops through mechanisms that include injury, inflammation, fibrosis and subsequent nerve compression.

  20. Time warp operating system version 2.7 internals manual

    Science.gov (United States)

    1992-01-01

    The Time Warp Operating System (TWOS) is an implementation of the Time Warp synchronization method proposed by David Jefferson. In addition, it serves as an actual platform for running discrete event simulations. The code comprising TWOS can be divided into several different sections. TWOS typically relies on an existing operating system to furnish some very basic services. This existing operating system is referred to as the Base OS. The existing operating system varies depending on the hardware TWOS is running on. It is Unix on the Sun workstations, Chrysalis or Mach on the Butterfly, and Mercury on the Mark 3 Hypercube. The base OS could be an entirely new operating system, written to meet the special needs of TWOS, but, to this point, existing systems have been used instead. The base OS's used for TWOS on various platforms are not discussed in detail in this manual, as they are well covered in their own manuals. Appendix G discusses the interface between one such OS, Mach, and TWOS.

  1. MEAN OF MEDIAN ABSOLUTE DERIVATION TECHNIQUE MEAN ...

    African Journals Online (AJOL)

    eobe

    development of mean of median absolute derivation technique based on the based on the based on .... of noise mean to estimate the speckle noise variance. Noise mean property ..... Foraging Optimization,” International Journal of. Advanced ...

  2. Efficient Architecture and Implementation of Vector Median Filter in Co-Design Context

    Directory of Open Access Journals (Sweden)

    N. Masmoudi

    2007-09-01

    Full Text Available This work presents an efficient fast parallel architecture of the Vector Median Filter (VMF using combined hardware/software (HW/SW implementation. The hardware part of the system is implemented using VHDL language, whereas the software part is developed using C/C++ language. The software part of the embedded system uses the NIOS-II softcore processor and the operating system used is μClinux. The comparison between the software and HW/SW solutions shows that adding a hardware part in the design attempts to speed up the filtering process compared to the software solution. This efficient embedded system implementation can perform well in several image processing applications.

  3. Electroacupuncture and Acupuncture Promote the Rat’s Transected Median Nerve Regeneration

    OpenAIRE

    Ho, C. Y.; Yao, C. H.; Chen, W. C.; Shen, W. C.; Bau, D. T.

    2013-01-01

    Background. Acupuncture and electroacupuncture treatments of damaged nerves may aid nerve regeneration related to hindlimb function, but the effects on the forelimb-related median nerve were not known. Methods. A gap was made in the median nerve of each rat by suturing the stumps into silicone rubber tubes. The influences of acupuncture and electroacupuncture treatments on transected median nerve regeneration were evaluated from morphological, electrophysiological, and functional angles. Resu...

  4. Hardware design of the median filter based on window structure and batcher′s oddeven sort network

    Directory of Open Access Journals (Sweden)

    SUN Kaimin

    2013-06-01

    Full Text Available Area and speed are two important factors to be considered in designing Median Filter with digital circuits.Area consideration requires the use of logical resources as little as possible,while speed consideration requires the system capable of working on higher clock frequencies,with as few clock cycles as possible to complete a frame filtering or real time filtering.This paper gives a new design of Median Filter,the hardware structure of which is a 3×3 window structure with two buffers.The filter function module is based on Batcher′s Odd-Even Sort network theory.Structural design is implemented in FPGA,verified by ModelSim software and realizes video image filtering.The experimental analysis shows that this new structure of Median Filter effectively decreases logical resources (merely using 741 Logic Elements,and accelerates the pixel processing speed up to 27MHz.This filter achieves realtime processing of video images of 30 frames/s.This design not only has a certain practicality,but also provides a reference for the hardware structure design ideas in digital image processing.

  5. Embedded real-time operating system micro kernel design

    Science.gov (United States)

    Cheng, Xiao-hui; Li, Ming-qiang; Wang, Xin-zheng

    2005-12-01

    Embedded systems usually require a real-time character. Base on an 8051 microcontroller, an embedded real-time operating system micro kernel is proposed consisting of six parts, including a critical section process, task scheduling, interruption handle, semaphore and message mailbox communication, clock managent and memory managent. Distributed CPU and other resources are among tasks rationally according to the importance and urgency. The design proposed here provides the position, definition, function and principle of micro kernel. The kernel runs on the platform of an ATMEL AT89C51 microcontroller. Simulation results prove that the designed micro kernel is stable and reliable and has quick response while operating in an application system.

  6. The Older of Two Trees: Young Children's Development of Operational Time

    Science.gov (United States)

    Kamii, Constance; Russell, Kelly A.

    2010-01-01

    Piaget (1971) made a distinction between intuitive (preoperational) time and operational (logico-mathematical) time. According to Piaget, operational time develops around 7-8 years of age and is characterized by children's ability to deduce, for example, that if A was born before B, A will always be older than B. When time is still intuitive,…

  7. Advanced Hard Real-Time Operating System, The Maruti Project. Part 1.

    Science.gov (United States)

    1997-01-01

    REAL - TIME OPERATING SYSTEM , THE MARUTI PROJECT Part 1 of 2 Ashok K. Agrawala Satish K. Tripathi Department of Computer Science University of Maryland...Hard Real - Time Operating System , The Maruti Project DASG-60-92-C-0055 5b. Program Element # 62301E 6. Author(s) 5c. Project # DRPB Ashok K. Agrawala...SdSA94), a real - time operating system developed at the I3nversity of Maryland, and conducted extensive experiments under various task

  8. Online Synthesis for Operation Execution Time Variability on Digital Microfluidic Biochips

    DEFF Research Database (Denmark)

    Alistar, Mirela; Pop, Paul

    2014-01-01

    have assumed that each biochemical operation in an application is characterized by a worst-case execution time (wcet). However, during the execution of the application, due to variability and randomness in biochemical reactions, operations may finish earlier than their wcets. In this paper we propose...... an online synthesis strategy that re-synthesizes the application at runtime when operations experience variability in their execution time, obtaining thus shorter application execution times. The proposed strategy has been evaluated using several benchmarks....

  9. Operating system for a real-time multiprocessor propulsion system simulator

    Science.gov (United States)

    Cole, G. L.

    1984-01-01

    The success of the Real Time Multiprocessor Operating System (RTMPOS) in the development and evaluation of experimental hardware and software systems for real time interactive simulation of air breathing propulsion systems was evaluated. The Real Time Multiprocessor Operating System (RTMPOS) provides the user with a versatile, interactive means for loading, running, debugging and obtaining results from a multiprocessor based simulator. A front end processor (FEP) serves as the simulator controller and interface between the user and the simulator. These functions are facilitated by the RTMPOS which resides on the FEP. The RTMPOS acts in conjunction with the FEP's manufacturer supplied disk operating system that provides typical utilities like an assembler, linkage editor, text editor, file handling services, etc. Once a simulation is formulated, the RTMPOS provides for engineering level, run time operations such as loading, modifying and specifying computation flow of programs, simulator mode control, data handling and run time monitoring. Run time monitoring is a powerful feature of RTMPOS that allows the user to record all actions taken during a simulation session and to receive advisories from the simulator via the FEP. The RTMPOS is programmed mainly in PASCAL along with some assembly language routines. The RTMPOS software is easily modified to be applicable to hardware from different manufacturers.

  10. How Much Volume of Local Anesthesia and How Long Should You Wait After Injection for an Effective Wrist Median Nerve Block?

    Science.gov (United States)

    Lovely, Lyndsay M; Chishti, Yasmin Z; Woodland, Jennifer L; Lalonde, Donald H

    2018-05-01

    Many surgeons and emergentologists use non-ultrasound-guided wrist nerve blocks. There is little evidence to guide the ideal volume of local anesthesia or how long we should wait after injection before performing pain-free procedures. This pilot study examined time to maximal anesthesia to painful needle stick in 14 volunteer participants receiving bilateral wrist blocks of 6 versus 11 mL of local. One surgeon performed all 14 bilateral wrist median nerve blocks in participants who remained blinded until after bandages were applied to their wrist. No one could see which wrist received the larger 11-mL volume injection versus the 6-mL block. Blinded sensory assessors then measured perceived maximal numbness time and numbness to needle stick pain in the fingertips of the median nerve distribution. Failure to get a complete median nerve block occurred in seven of fourteen 6-mL wrist blocks versus failure in only one of fourteen 11-mL blocks. Perceived maximal numbness occurred at roughly 40 minutes after injection, but actual numbness to painful needle stick took around 100 minutes. Incomplete median nerve numbness occurred with both 6- and 11-mL non-ultrasound-guided blocks at the wrist. In those with complete blocks, it took a surprisingly long time of 100 minutes for maximal anesthesia to occur to painful needle stick stimuli to the fingertips of the median nerve distribution. Non-ultrasound-guided median nerve blocks at the wrist as described in this article lack reliability and take too long to work.

  11. Lapset median käyttäjinä

    OpenAIRE

    Jalonen, Taru; Suomela, Sonja

    2010-01-01

    Laurea-ammattikorkeakoulu Tiivistelmä Hyvinkää Sosiaali-, terveys- ja liikunta-ala Hoitotyön koulutusohjelma Terveydenhoitaja AMK Sairaanhoitaja AMK Taru Jalonen, Sonja Suomela Lapset median käyttäjinä Vuosi ‎2010‎ Sivumäärä ‎63‎ Tämän opinnäytetyön tarkoituksena oli selvittää lasten tottumuksia ja kokemuksia mediasta sekä ‎niiden herättämiä tunteita. Lisäksi selvitimme lasten käyttämiä mediaympäristöjä sekä median ‎näkymistä lasten leikeissä. Tämä työ on os...

  12. Optimal design of work zone median crossovers.

    Science.gov (United States)

    2010-09-01

    The use of temporary median crossovers in work zones allows for the closure of one side of a multi-lane roadway while : maintaining two-way traffic on the opposite side. This process provides the ability for construction and maintenance crews : to co...

  13. Years Versus Days Between Successive Surgeries, After an Initial Outpatient Procedure, for the Median Patient Versus the Median Surgeon in the State of Iowa.

    Science.gov (United States)

    Dexter, Franklin; Jarvie, Craig; Epstein, Richard H

    2018-03-01

    Previously, we studied the relative importance of different institutional interventions that the largest hospital in Iowa could take to grow the anesthesia department's outpatient surgical care. Most (>50%) patients having elective surgery had not previously had surgery at the hospital. Patient perioperative experience was unimportant for influencing total anesthesia workload and numbers of patients. More important was the availability of surgical clinic appointments within several days. These results would be generalizable if the median time from surgery to a patient's next surgical procedure was large (eg, >2 years), among all hospitals in Iowa with outpatient surgery, and without regard to the hospital where the next procedure was performed. There were 37,172 surgical cases at hospital outpatient departments of any of the 117 hospitals in Iowa from July 1, 2013, to September 30, 2013. Data extracted about each case included its intraoperative work relative value units. The 37,172 cases were matched to all inpatient and outpatient records for the next 2 years statewide using patient linkage identifiers; from these were determined whether the patient had surgery again within 2 years. Furthermore, the cases' 1820 surgeons were matched to the surgeon's next outpatient or inpatient case, both including and excluding other cases performed on the date of the original case. By patient, the median time to their next surgical case, either outpatient or inpatient, exceeded 2 years, tested with weighting by intraoperative relative value units and repeated when unweighted (both P 2 years for patients versus 1 day for surgeons. Thus, although patients' experiences are an important attribute of quality of care, surgeons' experiences are orders of magnitude more important from the vantage point of marketing and growth of an anesthesia practice.

  14. Timing of ileocolonic resection for symptomatic Crohn's disease--the patient's view.

    OpenAIRE

    Scott, N A; Hughes, L E

    1994-01-01

    Eighty patients were asked if they would have preferred their ileocolonic resection and anastomosis for Crohn's disease, to have been carried out sooner, later or at the same time as it was done. Seventy of the patients replied (88%). No patient would have preferred their operation to have been later, while 74% thought it should have been earlier. A preferred operation time was given for 69 resections, between 0 months--that is, at the same time--and 15 years earlier. The median preferred ope...

  15. Response times of operators in a control room

    International Nuclear Information System (INIS)

    Platz, O.; Rasmussen, J.; Skanborg, P.Z.

    1982-12-01

    A statistical analysis was made of operator response times recorded in the control room of a research reactor during the years 1972-1974. A homogeneity test revealed that the data consist of a mixture of populations. A small but statistically significant difference is found between day and night response times. Lognormal distributions are found to provide the best fit of the day and the night response times. (author)

  16. Sosiaalisen median markkinointisuunnitelma uudelle hoitoalan konseptoidulle työvaatemallistolle

    OpenAIRE

    Leppälä, Sanna

    2017-01-01

    Opinnäytetyössä pohdittiin keinoja saada uuden konseptoidun työvaatemalliston näkyvyyttä esille sosiaalisen median keinoin. Toimeksiantaja-yrityksenä toimi suomalainen Virtually Oy ja kohteena oli sen uusi hoitajille suunnattu työvaatemallisto. Malliston ympärille halutaan luoda kestävä brändi ja sosiaalisen median markkinointi on tukemassa brändin tunnettavuutta ja myyntiä. Sosiaalinen media ei yritysten välisessä liiketoiminnassa toimi ainoana markkinoinnin työkaluna, vaan se on tukemas...

  17. The Optimal Timing of Stage-2-Palliation After the Norwood Operation.

    Science.gov (United States)

    Meza, James M; Hickey, Edward; McCrindle, Brian; Blackstone, Eugene; Anderson, Brett; Overman, David; Kirklin, James K; Karamlou, Tara; Caldarone, Christopher; Kim, Richard; DeCampli, William; Jacobs, Marshall; Guleserian, Kristine; Jacobs, Jeffrey P; Jaquiss, Robert

    2018-01-01

    The effect of the timing of stage-2-palliation (S2P) on survival through single ventricle palliation remains unknown. This study investigated the optimal timing of S2P that minimizes pre-S2P attrition and maximizes post-S2P survival. The Congenital Heart Surgeons' Society's critical left ventricular outflow tract obstruction cohort was used. Survival analysis was performed using multiphase parametric hazard analysis. Separate risk factors for death after the Norwood and after S2P were identified. Based on the multivariable models, infants were stratified as low, intermediate, or high risk. Cumulative 2-year, post-Norwood survival was predicted. Optimal timing was determined using conditional survival analysis and plotted as 2-year, post-Norwood survival versus age at S2P. A Norwood operation was performed in 534 neonates from 21 institutions. The S2P was performed in 71%, at a median age of 5.1 months (IQR: 4.3 to 6.0), and 22% died after Norwood. By 5 years after S2P, 10% of infants had died. For low- and intermediate-risk infants, performing S2P after age 3 months was associated with 89% ± 3% and 82% ± 3% 2-year survival, respectively. Undergoing an interval cardiac reoperation or moderate-severe right ventricular dysfunction before S2P were high-risk features. Among high-risk infants, 2-year survival was 63% ± 5%, and even lower when S2P was performed before age 6 months. Performing S2P after age 3 months may optimize survival of low- and intermediate-risk infants. High-risk infants are unlikely to complete three-stage palliation, and early S2P may increase their risk of mortality. We infer that early referral for cardiac transplantation may increase their chance of survival. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Successful strategies for the reduction of operating room turnover times in a tertiary care academic medical center.

    Science.gov (United States)

    Kodali, Bhavani S; Kim, Dennie; Bleday, Ronald; Flanagan, Hugh; Urman, Richard D

    2014-04-01

    Turnover time (TOT) is one of the classic measures of operating room (OR) efficiency. There have been numerous efforts to reduce TOTs, sometimes through the employment of a process improvement framework. However, most examples of process improvement in the TOT focus primarily on operational changes to workflows and statistical significance. These examples of process improvement do not detail the complex organizational challenges associated with implementing, expanding, and sustaining change. TOT data for general and gastrointestinal surgery were collected retrospectively over a 26-mo period at a large multispecialty academic institution. We calculated mean and median TOTs. TOTs were excluded if the sequence of cases was changed or cases were canceled. Data were retrieved from the perioperative nursing data entry system. Using performance improvement strategies, we determined how various events and organizational factors created an environment that was receptive to change. This ultimately led to a sustained decrease in the OR TOT both in the general and gastrointestinal surgery ORs that were the focus of the study (44.8 min versus 48.6 min; P managers, and change agents commonly face. Awareness of the numerous variables that may support or impede a particular change effort can inform effective change implementation strategies that are "organizationally compatible." Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Real-time embedded systems open-source operating systems perspective

    CERN Document Server

    Bertolotti, Ivan Cibrario

    2012-01-01

    From the Foreword: "!the presentation of real-time scheduling is probably the best in terms of clarity I have ever read in the professional literature. Easy to understand, which is important for busy professionals keen to acquire (or refresh) new knowledge without being bogged down in a convoluted narrative and an excessive detail overload. The authors managed to largely avoid theoretical-only presentation of the subject, which frequently affects books on operating systems. ! an indispensable [resource] to gain a thorough understanding of the real-time systems from the operating systems p

  20. Assessment of resident operative performance using a real-time mobile Web system: preparing for the milestone age.

    Science.gov (United States)

    Wagner, Justin P; Chen, David C; Donahue, Timothy R; Quach, Chi; Hines, O Joe; Hiatt, Jonathan R; Tillou, Areti

    2014-01-01

    To satisfy trainees' operative competency requirements while improving feedback validity and timeliness using a mobile Web-based platform. The Southern Illinois University Operative Performance Rating Scale (OPRS) was embedded into a website formatted for mobile devices. From March 2013 to February 2014, faculty members were instructed to complete the OPRS form while providing verbal feedback to the operating resident at the conclusion of each procedure. Submitted data were compiled automatically within a secure Web-based spreadsheet. Conventional end-of-rotation performance (CERP) evaluations filed 2006 to 2013 and OPRS performance scores were compared by year of training using serial and independent-samples t tests. The mean CERP scores and OPRS overall resident operative performance scores were directly compared using a linear regression model. OPRS mobile site analytics were reviewed using a Web-based reporting program. Large university-based general surgery residency program. General Surgery faculty used the mobile Web OPRS system to rate resident performance. Residents and the program director reviewed evaluations semiannually. Over the study period, 18 faculty members and 37 residents logged 176 operations using the mobile OPRS system. There were 334 total OPRS website visits. Median time to complete an evaluation was 45 minutes from the end of the operation, and faculty spent an average of 134 seconds on the site to enter 1 assessment. In the 38,506 CERP evaluations reviewed, mean performance scores showed a positive linear trend of 2% change per year of training (p = 0.001). OPRS overall resident operative performance scores showed a significant linear (p = 0.001), quadratic (p = 0.001), and cubic (p = 0.003) trend of change per year of clinical training, reflecting the resident operative experience in our training program. Differences between postgraduate year-1 and postgraduate year-5 overall performance scores were greater with the OPRS (mean = 0.96, CI

  1. The energy-momentum operator in curved space-time

    International Nuclear Information System (INIS)

    Brown, M.R.; Ottewill, A.C.

    1983-01-01

    It is argued that the only meaningful geometrical measure of the energy-momentum of states of matter described by a free quantum field theory in a general curved space-time is that provided by a normal ordered energy-momentum operator. The finite expectation values of this operator are contrasted with the conventional renormalized expectation values and it is further argued that the use of renormalization theory is inappropriate in this context. (author)

  2. Sosiaalisen median rooli mikroyrittäjän ostoprosessissa

    OpenAIRE

    Martikainen, Inkeri

    2014-01-01

    Opinnäytetyön tavoite oli selvittää sosiaalisen median rooli mikroyrittäjän ostoprosessissa; miten mikroyrittäjä hakee tietoa sosiaalisesta mediasta ja millainen vaikutus sieltä löytyvillä käyttäjäarvioilla on ostopäätökseen. Opinnäytetyö tehtiin erään finanssialan yrityksen toimeksiantona. Opinnäytetyön tarkoituksena oli antaa digitaalisen markkinoinnin ammattilaisille tietoa siitä, miten mikroyrittäjiä voidaan tavoittaa sosiaalisen median kautta, ja saada näin uusia asiakkaita. Tutkimus...

  3. Median forehead flap - beyond classic indication

    Directory of Open Access Journals (Sweden)

    Cristian R. Jecan

    2016-11-01

    Full Text Available Introduction. The paramedian forehead flap is one of the best options for reconstruction of the median upper two-thirds of the face due to its vascularity, color, texture match and ability to resurface all or part of the reconstructed area. The forehead flap is the gold standard for nasal soft tissue reconstruction and the flap of choice for larger cutaneous nasal defects having a robust pedicle and large amount of tissue. Materials and Methods. We are reporting a clinical series of cutaneous tumors involving the nose, medial canthus, upper and lower eyelid through a retrospective review of 6 patients who underwent surgical excision of the lesion and primary reconstruction using a paramedian forehead flap. Results. The forehead flap was used for total nose reconstruction, eyelids and medial canthal reconstruction. All flaps survived completely and no tumor recurrence was seen in any of the patients. Cosmetic and functional results were favorable. Conclusions. The forehead flap continues to be one of the best options for nose reconstruction and for closure of surgical defects of the nose larger than 2 cm. Even though is not a gold standard, median forehead flap can be an advantageous technique in periorbital defects reconstruction.

  4. Ultrahigh-frequency ultrasound of fascicles in the median nerve at the wrist.

    Science.gov (United States)

    Cartwright, Michael S; Baute, Vanessa; Caress, James B; Walker, Francis O

    2017-10-01

    An ultrahigh-frequency (70 MHZ) ultrasound device has recently been approved for human use. This study seeks to determine whether this device facilitates counting of fascicles within the median nerve at the wrist. Twenty healthy volunteers underwent imaging of the median nerve at the wrist bilaterally. The number of fascicles in each nerve was counted by two independent raters. The mean fascicle number was 22.68. Correlation was strong between the two raters (r = 0.68, P nerve area did not predict fascicle number. Those with bifid median nerves and persistent median arteries had lower fascicle density than those without anatomic anomalies (1.79 vs. 2.29; P = 0.01). Fascicles within the median nerve at the wrist can be readily imaged. Ultrahigh-frequency ultrasound technology may be informative in a variety of disorders affecting the peripheral nervous system. Muscle Nerve 56: 819-822, 2017. © 2017 Wiley Periodicals, Inc.

  5. Welded repair joints of boiler steels following operation in creep conditions exceeding the design time of operation

    Energy Technology Data Exchange (ETDEWEB)

    Dobrzanski, J.; Paszkowska, H.; Zielinski, A. [Institute for Ferrous Metallurgy, Gliwice (Poland)

    2010-07-01

    The assessment of suitability for further operation for materials and welded repair joints of thick-walled main steam pipeline components, made of steel 14MoV63, as well as steam superheater outlet headers made of steel X20CrMoV121 following operation in creep conditions in time periods considerably longer than the specified calculated time of operation. Strength properties, impact strength and transition temperature into brittle condition, as well as structure condition have been evaluated. On the basis of shortened creep tests, the residual life and disposable residual life of materials and welded joints have been determined. Material properties following operation and those of fabricated circumferential welded repair joints have been compared. The condition of examined components and suitability of the fabricated welded repair joints for further operation have been assessed. (orig.)

  6. Program-level and contextual-level determinants of low-median CD4+ cell count in cohorts of persons initiating ART in eight sub-Saharan African countries.

    Science.gov (United States)

    Nash, Denis; Wu, Yingfeng; Elul, Batya; Hoos, David; El Sadr, Wafaa

    2011-07-31

    In sub-Saharan Africa, many patients initiate antiretroviral therapy (ART) at CD4 cell counts much lower than those recommended in national guidelines. We examined program-level and contextual-level factors associated with low median CD4 cell count at ART initiation in populations initiating ART. Multilevel analysis of aggregate and program-level service delivery data. We examined data on 1690 cohorts of patients initiating ART during 2004-2008 in eight sub-Saharan African countries. Cohorts with median CD4 less than 111 cells/μl (the lowest quartile) were classified as having low median CD4 cell count at ART initiation. Cohort information was combined with time-updated program-level data and subnational contextual-level data, and analyzed using multilevel models. The 1690 cohorts had median CD4 cell count of 136 cells/μl and included 121,504 patients initiating ART at 267 clinics. Program-level factors associated with low cohort median CD4 cell count included urban setting [adjusted odds ratio (AOR) 2.1; 95% confidence interval (CI) 1.3-3.3], lower provider-to-patient ratio (AOR 2.2; 95% CI 1.3-4.0), no PMTCT program (AOR 3.6; 95% CI 1.0-12.8), outreach services for ART patients only vs. both pre-ART and ART patients (AOR 2.4; 95% CI 1.5-3.9), fewer vs. more adherence support services (AOR 1.6; 95% CI 1.0-2.5), and smaller cohort size (AOR 2.5; 95% CI 1.4-4.5). Contextual-level factors associated with low cohort median CD4 cell count included initiating ART in areas where a lower proportion of the population heard of AIDS, tested for HIV recently, and a higher proportion believed 'limiting themselves to one HIV-uninfected sexual partner reduces HIV risk'. Determinants of CD4 cell count at ART initiation in populations initiating ART operate at multiple levels. Structural interventions targeting points upstream from ART initiation along the continuum from infection to diagnosis to care engagement are needed.

  7. A battery-operated pilot balloon time-signal generator

    Science.gov (United States)

    Ralph H. Moltzau

    1966-01-01

    Describes the design and construction of a 1-pound, battery-operated, time-signal transmitter, which is usable with portable radio or field telephone circuits for synchronizing multi-theodolite observation of pilot balloons.

  8. Determination operation Time Risk of Box Spinning Components-oe Spinning Machine

    OpenAIRE

    Slobodan Stefanovic

    2013-01-01

    Based on the constructed dependency diagram reliability of the exploitation operation time of each constituent components of the analyzed frame in the case of selected statistical distributions, areas of the operation exploitation and repair intervals are determined. This is done by determining the first inflection points. Based on these points analysis to determine the time of safety operation of frame components with allowable risk to the segmental linear function of the intensity of failur...

  9. Median Robust Extended Local Binary Pattern for Texture Classification.

    Science.gov (United States)

    Liu, Li; Lao, Songyang; Fieguth, Paul W; Guo, Yulan; Wang, Xiaogang; Pietikäinen, Matti

    2016-03-01

    Local binary patterns (LBP) are considered among the most computationally efficient high-performance texture features. However, the LBP method is very sensitive to image noise and is unable to capture macrostructure information. To best address these disadvantages, in this paper, we introduce a novel descriptor for texture classification, the median robust extended LBP (MRELBP). Different from the traditional LBP and many LBP variants, MRELBP compares regional image medians rather than raw image intensities. A multiscale LBP type descriptor is computed by efficiently comparing image medians over a novel sampling scheme, which can capture both microstructure and macrostructure texture information. A comprehensive evaluation on benchmark data sets reveals MRELBP's high performance-robust to gray scale variations, rotation changes and noise-but at a low computational cost. MRELBP produces the best classification scores of 99.82%, 99.38%, and 99.77% on three popular Outex test suites. More importantly, MRELBP is shown to be highly robust to image noise, including Gaussian noise, Gaussian blur, salt-and-pepper noise, and random pixel corruption.

  10. Succinct Dynamic Cardinal Trees with Constant Time Operations for Small Alphabet

    DEFF Research Database (Denmark)

    Davoodi, Pooya; Satti, Srinivasa Rao

    2011-01-01

    ) bits and performs the following operations in O(1) time: parent, child(i), label-child(alpha), degree, subtree-size, preorder, is-ancestor(x), insert-leaf (alpha), delete-leaf(alpha). The update times are amortized. The space is close to the information theoretic lower bound. The operations...

  11. MINIX4RT: a real-time operating system based on MINIX

    OpenAIRE

    Pessolani, Pablo Andrés

    2006-01-01

    Tanenbaum's MINIX Operating System was extended with a Real-Time microkernel and services to conform MINIX4RT, a Real-Time Operating System for academic uses that includes more flexible Interprocess Communications facilities supporting basic priority inheritance protocol, a fixed priority scheduler, timer and event driven interrupt management, statistics and Real-Time metrics gathering keeping backward compatibility with standard MINIX versions. Facultad de Informática

  12. Koopman Operator Framework for Time Series Modeling and Analysis

    Science.gov (United States)

    Surana, Amit

    2018-01-01

    We propose an interdisciplinary framework for time series classification, forecasting, and anomaly detection by combining concepts from Koopman operator theory, machine learning, and linear systems and control theory. At the core of this framework is nonlinear dynamic generative modeling of time series using the Koopman operator which is an infinite-dimensional but linear operator. Rather than working with the underlying nonlinear model, we propose two simpler linear representations or model forms based on Koopman spectral properties. We show that these model forms are invariants of the generative model and can be readily identified directly from data using techniques for computing Koopman spectral properties without requiring the explicit knowledge of the generative model. We also introduce different notions of distances on the space of such model forms which is essential for model comparison/clustering. We employ the space of Koopman model forms equipped with distance in conjunction with classical machine learning techniques to develop a framework for automatic feature generation for time series classification. The forecasting/anomaly detection framework is based on using Koopman model forms along with classical linear systems and control approaches. We demonstrate the proposed framework for human activity classification, and for time series forecasting/anomaly detection in power grid application.

  13. Extending the maximum operation time of the MNSR reactor.

    Science.gov (United States)

    Dawahra, S; Khattab, K; Saba, G

    2016-09-01

    An effective modification to extend the maximum operation time of the Miniature Neutron Source Reactor (MNSR) to enhance the utilization of the reactor has been tested using the MCNP4C code. This modification consisted of inserting manually in each of the reactor inner irradiation tube a chain of three polyethylene-connected containers filled of water. The total height of the chain was 11.5cm. The replacement of the actual cadmium absorber with B(10) absorber was needed as well. The rest of the core structure materials and dimensions remained unchanged. A 3-D neutronic model with the new modifications was developed to compare the neutronic parameters of the old and modified cores. The results of the old and modified core excess reactivities (ρex) were: 3.954, 6.241 mk respectively. The maximum reactor operation times were: 428, 1025min and the safety reactivity factors were: 1.654 and 1.595 respectively. Therefore, a 139% increase in the maximum reactor operation time was noticed for the modified core. This increase enhanced the utilization of the MNSR reactor to conduct a long time irradiation of the unknown samples using the NAA technique and increase the amount of radioisotope production in the reactor. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Early and late outcomes of 1000 minimally invasive aortic valve operations.

    Science.gov (United States)

    Tabata, Minoru; Umakanthan, Ramanan; Cohn, Lawrence H; Bolman, Ralph Morton; Shekar, Prem S; Chen, Frederick Y; Couper, Gregory S; Aranki, Sary F

    2008-04-01

    Minimal access cardiac valve surgery is increasingly utilized. We report our 11-year experience with minimally invasive aortic valve surgery. From 07/96 to 12/06, 1005 patients underwent minimally invasive aortic valve surgery. Early and late outcomes were analyzed. Median patient age was 68 years (range: 24-95), 179 patients (18%) were 80 years or older, 130 patients (13%) had reoperative aortic valve surgery, 86 (8.4%) had aortic root replacement, 62 (6.1%) had concomitant ascending aortic replacement, and 26 (2.6%) had percutaneous coronary intervention on the day of surgery (hybrid procedure). Operative mortality was 1.9% (19/1005). The incidences of deep sternal wound infection, pneumonia and reoperation for bleeding were 0.5% (5/1005), 1.3% (13/1005) and 2.4% (25/1005), respectively. Median length of stay was 6 days and 733 patients (72%) were discharged home. Actuarial survival was 91% at 5 years and 88% at 10 years. In the subgroup of the elderly (> or =80 years), operative mortality was 1.7% (3/179), median length of stay was 8 days and 66 patients (37%) were discharged home. Actuarial survival at 5 years was 84%. There was a significant decreasing trend in cardiopulmonary bypass time, the incidence of bleeding, and operative mortality over time. Minimal access approaches in aortic valve surgery are safe and feasible with excellent outcomes. Aortic root replacement, ascending aortic replacement, and reoperative surgery can be performed with these approaches. These procedures are particularly well-tolerated in the elderly.

  15. Race and time from diagnosis to radical prostatectomy: does equal access mean equal timely access to the operating room?--Results from the SEARCH database.

    Science.gov (United States)

    Bañez, Lionel L; Terris, Martha K; Aronson, William J; Presti, Joseph C; Kane, Christopher J; Amling, Christopher L; Freedland, Stephen J

    2009-04-01

    African American men with prostate cancer are at higher risk for cancer-specific death than Caucasian men. We determine whether significant delays in management contribute to this disparity. We hypothesize that in an equal-access health care system, time interval from diagnosis to treatment would not differ by race. We identified 1,532 African American and Caucasian men who underwent radical prostatectomy (RP) from 1988 to 2007 at one of four Veterans Affairs Medical Centers that comprise the Shared Equal-Access Regional Cancer Hospital (SEARCH) database with known biopsy date. We compared time from biopsy to RP between racial groups using linear regression adjusting for demographic and clinical variables. We analyzed risk of potential clinically relevant delays by determining odds of delays >90 and >180 days. Median time interval from diagnosis to RP was 76 and 68 days for African Americans and Caucasian men, respectively (P = 0.004). After controlling for demographic and clinical variables, race was not associated with the time interval between diagnosis and RP (P = 0.09). Furthermore, race was not associated with increased risk of delays >90 (P = 0.45) or >180 days (P = 0.31). In a cohort of men undergoing RP in an equal-access setting, there was no significant difference between racial groups with regard to time interval from diagnosis to RP. Thus, equal-access includes equal timely access to the operating room. Given our previous finding of poorer outcomes among African Americans, treatment delays do not seem to explain these observations. Our findings need to be confirmed in patients electing other treatment modalities and in other practice settings.

  16. Speckle Reduction and Structure Enhancement by Multichannel Median Boosted Anisotropic Diffusion

    Directory of Open Access Journals (Sweden)

    Yang Zhi

    2004-01-01

    Full Text Available We propose a new approach to reduce speckle noise and enhance structures in speckle-corrupted images. It utilizes a median-anisotropic diffusion compound scheme. The median-filter-based reaction term acts as a guided energy source to boost the structures in the image being processed. In addition, it regularizes the diffusion equation to ensure the existence and uniqueness of a solution. We also introduce a decimation and back reconstruction scheme to further enhance the processing result. Before the iteration of the diffusion process, the image is decimated and a subpixel shifted image set is formed. This allows a multichannel parallel diffusion iteration, and more importantly, the speckle noise is broken into impulsive or salt-pepper noise, which is easy to remove by median filtering. The advantage of the proposed technique is clear when it is compared to other diffusion algorithms and the well-known adaptive weighted median filtering (AWMF scheme in both simulation and real medical ultrasound images.

  17. The HAL 9000 Space Operating System Real-Time Planning Engine Design and Operations Requirements

    Science.gov (United States)

    Stetson, Howard; Watson, Michael D.; Shaughnessy, Ray

    2012-01-01

    In support of future deep space manned missions, an autonomous/automated vehicle, providing crew autonomy and an autonomous response planning system, will be required due to the light time delays in communication. Vehicle capabilities as a whole must provide for tactical response to vehicle system failures and space environmental effects induced failures, for risk mitigation of permanent loss of communication with Earth, and for assured crew return capabilities. The complexity of human rated space systems and the limited crew sizes and crew skills mix drive the need for a robust autonomous capability on-board the vehicle. The HAL 9000 Space Operating System[2] designed for such missions and space craft includes the first distributed real-time planning / re-planning system. This paper will detail the software architecture of the multiple planning engine system, and the interface design for plan changes, approval and implementation that is performed autonomously. Operations scenarios will be defined for analysis of the planning engines operations and its requirements for nominal / off nominal activities. An assessment of the distributed realtime re-planning system, in the defined operations environment, will be provided as well as findings as it pertains to the vehicle, crew, and mission control requirements needed for implementation.

  18. An investigation on the noise reduction performance of profiled rigid median barriers at highways

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Monazzam

    2012-01-01

    Full Text Available Median barriers as a portion of a divided highway are provided to minimize the cross-median crashes. Moreover, median barriers similar to roadside noise barriers could protect people from transportation noise. Thus, there is a need to investigate various median barrier models to identify changes of insertion loss over a simple rigid barrier. In order to estimate the acoustical influence of median barrier′s profile in the shadow zone, different median barrier models are presented and their insertion losses are calculated over a frequency range from 50 to 4000 Hz using a two-dimensional boundary element method. The present investigation has clearly revealed that among the profiled median barriers, T-shape, Y-shape, and L-shape provide better performance than that of the other shapes. It is also found that among inclined barriers, V-shape barrier significantly presents higher values of attenuation. Based on the calculation of different geometrics, it has been shown that a further 2 dB (A in efficiency could be obtained by a better design of the median barrier which is labeled model "L."

  19. Feynman's operational calculus and beyond noncommutativity and time-ordering

    CERN Document Server

    Johnson, George W; Nielsen, Lance

    2015-01-01

    This book is aimed at providing a coherent, essentially self-contained, rigorous and comprehensive abstract theory of Feynman's operational calculus for noncommuting operators. Although it is inspired by Feynman's original heuristic suggestions and time-ordering rules in his seminal 1951 paper An operator calculus having applications in quantum electrodynamics, as will be made abundantly clear in the introduction (Chapter 1) and elsewhere in the text, the theory developed in this book also goes well beyond them in a number of directions which were not anticipated in Feynman's work. Hence, the second part of the main title of this book. The basic properties of the operational calculus are developed and certain algebraic and analytic properties of the operational calculus are explored. Also, the operational calculus will be seen to possess some pleasant stability properties. Furthermore, an evolution equation and a generalized integral equation obeyed by the operational calculus are discussed and connections wi...

  20. Alpha: A real-time decentralized operating system for mission-oriented system integration and operation

    Science.gov (United States)

    Jensen, E. Douglas

    1988-01-01

    Alpha is a new kind of operating system that is unique in two highly significant ways. First, it is decentralized transparently providing reliable resource management across physically dispersed nodes, so that distributed applications programming can be done largely as though it were centralized. And second, it provides comprehensive, high technology support for real-time system integration and operation, an application area which consists predominately of aperiodic activities having critical time constraints such as deadlines. Alpha is extremely adaptable so that it can be easily optimized for a wide range of problem-specific functionality, performance, and cost. Alpha is the first systems effort of the Archons Project, and the prototype was created at Carnegie-Mellon University directly on modified Sun multiprocessor workstation hardware. It has been demonstrated with a real-time C(sup 2) application. Continuing research is leading to a series of enhanced follow-ons to Alpha; these are portable but initially hosted on Concurrent's MASSCOMP line of multiprocessor products.

  1. COLOUR IMAGE STEGANOGRAPHY USING MEDIAN MAINTENANCE

    Directory of Open Access Journals (Sweden)

    S. Arivazhagan

    2011-08-01

    Full Text Available Steganographic algorithms in the recent past have been producing stego images with perceptual invisibility, better secrecy and certain robustness against attacks like cropping, filtering etc. Recovering a good quality secret from a good quality stego image may not always be possible. The method proposed in this paper works in transform domain and attempts to extract the secret almost as same as the embedded one maintaining minimal changes to the cover image by using techniques like median maintenance, offset and quantization.

  2. Electromyogram median power frequency in dynamic exercise at medium exercise intensities

    NARCIS (Netherlands)

    Ament, W; Bonga, GJJ; Hof, AL; Verkerke, GJ

    The electromyogram (EMG) median power Frequency of the calf muscles was investigated during an exhausting treadmill exercise and a 20-min recovery period. The exercise was an uphill run at a speed of 5 km . h(-1) and a gradient of 20%. During exercise there was no decrease of EMG median power

  3. Real-Time Plasma Control Tools for Advanced Tokamak Operation

    International Nuclear Information System (INIS)

    Varandas, C. A. F.; Sousa, J.; Rodrigues, A. P.; Carvalho, B. B.; Fernandes, H.; Batista, A. J.; Cruz, N.; Combo, A.; Pereira, R. C.

    2006-01-01

    Real-time control will play an important role in the operation and scientific exploitation of the new generation fusion devices. This paper summarizes the real-time systems and diagnostics developed by the Portuguese Fusion Euratom Association based on digital signal processors and field programmable gate arrays

  4. Median mental sinus in twins.

    Science.gov (United States)

    Ong, S T; Ngeow, W C

    1999-05-01

    Sinus on the chin can be the result of a chronic apical abscess due to pulp necrosis of a mandibular anterior tooth. The tooth is usually asymptomatic, and a dental cause is therefore not apparent to the patient or the unsuspecting clinician. Not infrequently, the patient may seek treatment from a dermatologist or general surgeon instead of a dentist. Excision and repair of the fistula may be carried out with subsequent breakdown because the dental pathology is not removed. This paper reports the presence of median mental sinus of dental origin in twins. One case healed following root canal therapy while the other required both root canal therapy and surgery to eliminate the infection.

  5. Voimaa visuaalisuudesta : Narratiivinen kirjallisuuskatsaus visuaalisen sosiaalisen median vaikutuksista nuorten aikuisten hyvinvointiin

    OpenAIRE

    Viita, Shir

    2017-01-01

    Viita, Shir. Voimaa visuaalisuudesta – Narratiivinen kirjallisuuskatsaus visuaalisen sosiaalisen median vaikutuksista nuorten aikuisten hyvinvointiin. Kevät 2016. 52 s., 1 liite. Diakonia ammattikorkeakoulu. Sosiaalialan koulutusohjelma, sosionomin suuntautumisvaihtoehto. Sosionomi (AMK). Opinnäytetyön tavoitteena on tuottaa tietoa sosiaalialan ammattilaisille visuaalisen sosiaalisen median sivustojen Instagramin ja Snapchatin vaikutuksista nuorten aikuisten hyvinvointiin. Opinnäyte...

  6. Application of median-equation approach for outlier detection in geodetic networks

    Directory of Open Access Journals (Sweden)

    Serif Hekimoglu

    Full Text Available In geodetic measurements some outliers may occur sometimes in data sets, depending on different reasons. There are two main approaches to detect outliers as Tests for outliers (Baarda's and Pope's Tests and robust methods (Danish method, Huber method etc.. These methods use the Least Squares Estimation (LSE. The outliers affect the LSE results, especially it smears the effects of the outliers on the good observations and sometimes wrong results may be obtained. To avoid these effects, a method that does not use LSE should be preferred. The median is a high breakdown point estimator and if it is applied for the outlier detection, reliable results can be obtained. In this study, a robust method which uses median with or as a treshould value on median residuals that are obtained from median equations is proposed. If the a priori variance of the observations is known, the reliability of the new approch is greater than the one in the case where the a priori variance is unknown.

  7. A Parallel Priority Queue with Constant Time Operations

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Träff, Jesper Larsson; Zaroliagis, Christos D.

    1998-01-01

    We present a parallel priority queue that supports the following operations in constant time:parallel insertionof a sequence of elements ordered according to key,parallel decrease keyfor a sequence of elements ordered according to key,deletion of the minimum key element, anddeletion of an arbitrary...... application is a parallel implementation of Dijkstra's algorithm for the single-source shortest path problem, which runs inO(n) time andO(mlogn) work on a CREW PRAM on graphs withnvertices andmedges. This is a logarithmic factor improvement in the running time compared with previous approaches....

  8. Separate patient serum sodium medians from males and females provide independent information on analytical bias

    DEFF Research Database (Denmark)

    Hansen, Steen Ingemann; Petersen, Per Hyltoft; Lund, Flemming

    2017-01-01

    BACKGROUND: During monitoring of monthly medians of results from patients undertaken to assess analytical stability in routine laboratory performance, the medians for serum sodium for male and female patients were found to be significantly related. METHODS: Daily, weekly and monthly patient medians...... all instruments. CONCLUSIONS: The tight relationship between the gender medians for serum sodium is only possible when raw laboratory data are used for calculation. The two patient medians can be used to confirm both and are useful as independent estimates of analytical bias during constant...... calibration periods. In contrast to the gender combined median, the estimate of analytical bias can be confirmed further by calculation of the ratios of medians for males and females....

  9. A GPU-Based Genetic Algorithm for the P-Median Problem

    OpenAIRE

    AlBdaiwi, Bader F.; AboElFotoh, Hosam M. F.

    2016-01-01

    The p-median problem is a well-known NP-hard problem. Many heuristics have been proposed in the literature for this problem. In this paper, we exploit a GPGPU parallel computing platform to present a new genetic algorithm implemented in Cuda and based on a Pseudo Boolean formulation of the p-median problem. We have tested the effectiveness of our algorithm using a Tesla K40 (2880 Cuda cores) on 290 different benchmark instances obtained from OR-Library, discrete location problems benchmark li...

  10. Lightweight MAC-Spoof Detection Exploiting Received Signal Power and Median Filtering

    DEFF Research Database (Denmark)

    Papini, Davide

    2011-01-01

    this kind of attack based on signal power monitoring. The main contribution of our work is the introduction of a median l- ter that enables the detection of the attack by looking at the variance of the signal power. We take into account two types of references for the samples, time and number of frames......IEEE 802.11 networks are subject to MAC-spoof attacks. An attacker can easily steal the identity of a legitimate station, even Access Points, thus enabling him to take full control over network basic mech- anisms or even access restricted resources. In this paper we propose a method to detect...

  11. Median nerve fascicular anatomy as a basis for distal neural prostheses.

    Science.gov (United States)

    Planitzer, Uwe; Steinke, Hanno; Meixensberger, Jürgen; Bechmann, Ingo; Hammer, Niels; Winkler, Dirk

    2014-05-01

    Functional electrical stimulation (FES) serves as a possible therapy to restore missing motor functions of peripheral nerves by means of cuff electrodes. FES is established for improving lower limb function. Transferring this method to the upper extremity is complex, due to a lack of anatomical data on the physiological configuration of nerve fascicles. Our study's aim was to provide an anatomical basis for FES of the median nerve in the distal forearm and hand. We investigated 21 distal median nerves from 12 body donors. The peripheral fascicles were traced back by removing the external and interfascicular epineurium and then assigned to 4 quadrants. A distinct motor and sensory distribution was observed. The fascicles innervating the thenar eminence and the first lumbrical muscle originated from the nerves' radial parts in 82%. The fascicle supplying the second lumbrical muscle originated from the ulnar side in 78%. No macroscopically visible plexus formation was observed for the distal median nerve in the forearm. The findings on the distribution of the motor branches of the median nerve and the missing plexus formation may likely serve as an anatomical basis for FES of the distal forearm. However, due to the considerable variability of the motor branches, cuff electrodes will need to be adapted individually in FES. Taking into account the sensory distribution of the median nerve, FES may also possibly be applied in the treatment of regional pain syndromes. Copyright © 2013 Elsevier GmbH. All rights reserved.

  12. Variant palmaris profundus enclosed by an unusual loop of the median nerve

    Science.gov (United States)

    CHOU, HSIU-CHU; JENG, HELLEN; KO, TSUI-LING; PAI, MAN-HUI; CHANG, CHIU-YUN; WU, CHING-HSIANG

    2001-01-01

    According to the usual description in most anatomy texts, the median nerve in the forearm passes between the 2 heads of pronator teres. It continues distally between flexor digitorum superficialis and profundus almost to the retinaculum. Muscular branches leave the nerve near the elbow and supply all superficial muscles of the anterior part of the forearm except flexor carpi ulnaris. Many variations of the median nerve in the forearm have been reported (Urban & Krosman, 1992). The palmaris profundus is also a rare anomaly of the forearm (Dyreby & Engber, 1982). It originates from the radial side of the common flexor tendon in the proximal forearm and inserts into the undersurface of the palmar aponeurosis. The origin of palmaris profundus may be close to the median nerve and its branches, and may be involved in compressive neuropathy of the anterior interosseous nerve. Its tendon crossing through the carpal canal has been implicated in the carpal tunnel syndrome (reviewed by Lahey & Aulicino, 1986). In some cases, palmaris profundus was found enclosed in a common fascial sheath with the median nerve (Stark, 1992; Sahinoglu et al. 1994). To indicate its close association with the median nerve, the palmaris profundus was also named ‘musculus comitans nervi mediani’ (Sahinoglu et al. 1994). This article reports an unusual loop of the median nerve encircling an anomalous palmaris profundus in the forearm, which, to the best of our knowledge, has not been previously described. PMID:11693311

  13. Least median of squares filtering of locally optimal point matches for compressible flow image registration

    International Nuclear Information System (INIS)

    Castillo, Edward; Guerrero, Thomas; Castillo, Richard; White, Benjamin; Rojo, Javier

    2012-01-01

    Compressible flow based image registration operates under the assumption that the mass of the imaged material is conserved from one image to the next. Depending on how the mass conservation assumption is modeled, the performance of existing compressible flow methods is limited by factors such as image quality, noise, large magnitude voxel displacements, and computational requirements. The Least Median of Squares Filtered Compressible Flow (LFC) method introduced here is based on a localized, nonlinear least squares, compressible flow model that describes the displacement of a single voxel that lends itself to a simple grid search (block matching) optimization strategy. Spatially inaccurate grid search point matches, corresponding to erroneous local minimizers of the nonlinear compressible flow model, are removed by a novel filtering approach based on least median of squares fitting and the forward search outlier detection method. The spatial accuracy of the method is measured using ten thoracic CT image sets and large samples of expert determined landmarks (available at www.dir-lab.com). The LFC method produces an average error within the intra-observer error on eight of the ten cases, indicating that the method is capable of achieving a high spatial accuracy for thoracic CT registration. (paper)

  14. Nonunitary similarity transformation of conservative to dissipative evolutions: Intertwining without time operator

    Science.gov (United States)

    Gómez, Fernando

    2007-04-01

    Reversible evolutions are usually expressed in terms of unitary groups on separable Hilbert spaces, whereas irreversible ones are described by contraction semigroups. In the theory of nonunitary similarity transformations intertwining unitary groups and contraction semigroups, proposed initially in the context of statistical mechanics as part of an exact theory of irreversibility, the unitary groups with such intertwining property have been qualified by the existence of an internal time operator. This work tackles the question of existence of internal time operators for unitary groups with the intertwining property. Equivalent conditions to the existence of internal time operators for such unitary groups are given on the basis of the Sz.-Nagy-Foiaş [Harmonic Analysis of Operators on Hilbert Spaces (North-Holland, Amsterdam, 1970)] dilation theory and the theory of shift invariant subspaces. These conditions permit us to solve the inverse intertwining problem in the negative: there are unitary groups with the intertwining property which do not admit internal time operator. A representative family of such unitary groups is given.

  15. Social Security: a financial appraisal for the median voter.

    Science.gov (United States)

    Galasso, V

    Several explanations have been proposed for why voters continue to support unfunded social security systems. Browning (1975) suggests that the extremely large unfunded pension systems of most democracies depend on the existence of a voting majority composed of middle-aged and older people who fail to fully internalize the cost of financing the system. In fact, when voting, economically rational workers consider only their current and future contributions to the system and their expected pension benefits--not their past contributions, which they regard as sunk costs. If, for a majority of voters, the expected continuation return from social security exceeds the return from alternative assets, an unfunded social security system is politically sustainable. This article explores the validity of Browning's proposition by quantifying the returns that U.S. voters in presidential elections from 1964 to 1996 have obtained, or expect to obtain, from Social Security. Did "investments" in Social Security outperform alternative forms of investment, such as mutual funds or pension funds, for a majority of the voters? What can be expected for the future? The U.S. Social Security system redistributes income within age cohorts on the basis of sex, income, and marital status. To account for some of these features, the median voter is represented by a family unit whose members--a husband who accounts for 70 percent of household earnings and a wife who accounts for 30 percent--make joint economic and voting decisions. Thus, retirement and survival benefits paid out to the spouse of an insured worker can be included in the calculation of Social Security returns. Interval estimates of voters' family incomes from the U.S. Census Bureau were used to obtain the median voter's household earnings. The median voter's age is derived from the ages of those who voted in presidential elections, not from the ages of the entire electorate. The median voter's contributions to Social Security are the

  16. When Is the Optimal Timing of the Surgical Treatment for Secondary Spontaneous Pneumothorax?

    Science.gov (United States)

    Jeon, Hyun Woo; Kim, Young-Du; Choi, Si Young; Park, Jae Kil

    2017-01-01

    Objectives  The definition of spontaneous pneumothorax is accumulation of air in the pleural space, resulting in dyspnea or chest pain. Unlike primary spontaneous pneumothorax, secondary pneumothorax can be a life-threatening condition and spontaneous healing rate is uncommon. Although surgery is the most effective treatment modality for pneumothorax, surgical management and timing is difficult where there is underlying lung disease and/or medical comorbidities. Prolonged air leakage increases the morbidity and mortality in thoracic surgery. We hypothesized that duration of air leakage before operation may lead to increase in complications. Methods  This study is a retrospective review of 155 consecutive patients with air leakage who underwent bullectomy for secondary spontaneous pneumothorax from January 2005 to July 2013. The patients were divided according to the duration of preoperative air leakage. The patients were followed-up until the time of last visit or death. Postoperative morbidity and mortality were assessed and the risk factors for complications were analyzed. Results  The median age was 65 years (range, 52-88) with male predominance (96.13%). The median duration of preoperative air leakage was 6 days (range, 1-30). The median surgery time was 90 minutes (range, 25-300) and median hospital stay after operation was 7 days (range, 3-75). Postoperative complications occurred in 38 patients (24.52%) and postoperative recurrence was shown to have occurred in 8 patients (5.16%). With multivariate analysis, risk factors for postoperative complications were: underlying interstitial lung disease and air leakage > 5 days before operation. Conclusion  Persistent air leakage was a major surgical indication for pneumothorax. Early surgical treatment reduced postoperative complications for secondary spontaneous pneumothorax. Georg Thieme Verlag KG Stuttgart · New York.

  17. An O(n log n) Version of the Averbakh-Berman Algorithm for the Robust Median of a Tree

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Georgiadis, Loukas; Katriel, Irit

    2008-01-01

    We show that the minmax regret median of a tree can be found in O(nlog n) time. This is obtained by a modification of Averbakh and Berman's O(nlog2 n)-time algorithm: We design a dynamic solution to their bottleneck subproblem of finding the middle of every root-leaf path in a tree....

  18. The Median Solution of the Newsvendor Problem and Some Observations

    Directory of Open Access Journals (Sweden)

    Sinha Pritibhushan

    2015-09-01

    Full Text Available We consider the median solution of the Newsvendor Problem. Some properties of such a solution are shown through a theoretical analysis and a numerical experiment. Sometimes, though not often, median solution may be better than solutions maximizing expected profit, or maximizing minimum possible, over distribution with the same average and standard deviation, expected profit, according to some criteria. We discuss the practical suitability of the objective function set and the solution derived, for the Newsvendor Problem, and other such random optimization problems.

  19. Real-time solar magnetograph operation system software design and user's guide

    Science.gov (United States)

    Wang, C.

    1984-01-01

    The Real Time Solar Magnetograph (RTSM) Operation system software design on PDP11/23+ is presented along with the User's Guide. The RTSM operation software is for real time instrumentation control, data collection and data management. The data is used for vector analysis, plotting or graphics display. The processed data is then easily compared with solar data from other sources, such as the Solar Maximum Mission (SMM).

  20. Preliminary Investigation of Time Remaining Display on the Computer-based Emergency Operating Procedure

    Science.gov (United States)

    Suryono, T. J.; Gofuku, A.

    2018-02-01

    One of the important thing in the mitigation of accidents in nuclear power plant accidents is time management. The accidents should be resolved as soon as possible in order to prevent the core melting and the release of radioactive material to the environment. In this case, operators should follow the emergency operating procedure related with the accident, in step by step order and in allowable time. Nowadays, the advanced main control rooms are equipped with computer-based procedures (CBPs) which is make it easier for operators to do their tasks of monitoring and controlling the reactor. However, most of the CBPs do not include the time remaining display feature which informs operators of time available for them to execute procedure steps and warns them if the they reach the time limit. Furthermore, the feature will increase the awareness of operators about their current situation in the procedure. This paper investigates this issue. The simplified of emergency operating procedure (EOP) of steam generator tube rupture (SGTR) accident of PWR plant is applied. In addition, the sequence of actions on each step of the procedure is modelled using multilevel flow modelling (MFM) and influenced propagation rule. The prediction of action time on each step is acquired based on similar case accidents and the Support Vector Regression. The derived time will be processed and then displayed on a CBP user interface.

  1. Decreasing delays in urgent and expedited surgery in a university teaching hospital through audit and communication between peri-operative and surgical directorates.

    Science.gov (United States)

    Cosgrove, J F; Gaughan, M; Snowden, C P; Lees, T

    2008-06-01

    National Confidential Enquiry into Patient Outcome and Death guidelines for urgent surgery recommend a fully staffed emergency operating theatre and restriction of 'after-midnight' operating to immediate life-, limb- or organ-threatening conditions. Audit performed in our institution demonstrated significant decreases in waiting times for urgent surgery and an increased seniority of medical care associated with overnight pre-operative assessment of patients by anaesthetic trainees. Nevertheless, urgent cases continued to be delayed unnecessarily. A classification of delays was developed from existing guidelines and their incidence was audited. The results were disseminated to involved directorates. A repeat of the audit demonstrated a significant decrease in delays (p = 0.001), a significant increase in the availability of surgeons (p = 0.001) and a significant decrease in the median waiting time for urgent surgery compared to the first audit cycle and a previous standard (p auditing delays and disseminating the results of the audit significantly decreases delays and median waiting times for urgent surgery because of improved surgical availability.

  2. Myofibroma in the Palm Presenting with Median Nerve Compression Symptoms

    Directory of Open Access Journals (Sweden)

    Heidi Sarkozy, PA-C, BS

    2014-08-01

    Full Text Available Summary: A myofibroma is a benign proliferation of myofibroblasts in the connective tissue. Solitary myofibromas are a rare finding especially in an adult. We report a case of a 23-year-old man presenting with an enlarging mass over his right palm. The patient is an active weight lifter. He reported numbness and tingling in the median nerve distribution. Nerve conduction studies and magnetic resonance imaging scans suggested a tumor involving or compressing the median nerve. The final diagnosis of myofibroma was made only after the histopathological diagnosis.

  3. Ranking Exponential Trapezoidal Fuzzy Numbers by Median Value

    Directory of Open Access Journals (Sweden)

    S. Rezvani

    2013-12-01

    Full Text Available In this paper, we want represented a method for ranking of two exponential trapezoidal fuzzy numbers. A median value is proposed for the ranking of exponential trapezoidal fuzzy numbers. For the validation the results of the proposed approach are compared with different existing approaches.

  4. Predictors of shoulder dystocia at the time of operative vaginal delivery.

    Science.gov (United States)

    Palatnik, Anna; Grobman, William A; Hellendag, Madeline G; Janetos, Timothy M; Gossett, Dana R; Miller, Emily S

    2016-11-01

    It remains uncertain whether clinical factors known prior to delivery can predict which women are more likely to experience shoulder dystocia in the setting of operative vaginal delivery. We sought to identify whether shoulder dystocia can be accurately predicted among women undergoing an operative vaginal delivery. This was a case-control study of women undergoing a low or outlet operative vaginal delivery from 2005 through 2014 in a single tertiary care center. Cases were defined as women who experienced a shoulder dystocia at the time of operative vaginal delivery. Controls consisted of women without a shoulder dystocia at the time of operative vaginal delivery. Variables previously identified to be associated with shoulder dystocia that could be known prior to delivery were abstracted from the medical records. Bivariable analyses and multivariable logistic regression were used to identify factors independently associated with shoulder dystocia. A receiver operating characteristic curve was created to evaluate the predictive value of the model for shoulder dystocia. Of the 4080 women who met inclusion criteria, shoulder dystocia occurred in 162 (4.0%) women. In bivariable analysis, maternal age, parity, body mass index, diabetes, chorioamnionitis, arrest disorder as an indication for an operative vaginal delivery, vacuum use, and estimated fetal weight >4 kg were significantly associated with shoulder dystocia. In multivariable analysis, parity, diabetes, chorioamnionitis, arrest disorder as an indication for operative vaginal delivery, vacuum use, and estimated fetal weight >4 kg remained independently associated with shoulder dystocia. The area under the curve for the generated receiver operating characteristic curve was 0.73 (95% confidence interval, 0.69-0.77), demonstrating only a modest ability to predict shoulder dystocia before performing an operative vaginal delivery. While risk factors for shoulder dystocia at the time of operative vaginal delivery

  5. Real time operating system for a nuclear power plant computer

    International Nuclear Information System (INIS)

    Alger, L.S.; Lala, J.H.

    1986-01-01

    A quadruply redundant synchronous fault tolerant processor (FTP) is now under fabrication at the C.S. Draper Laboratory to be used initially as a trip monitor for the Experimental Breeder Reactor EBR-II operated by the Argonne National Laboratory in Idaho Falls, Idaho. The real time operating system for this processor is described

  6. ASPECTS REGARDING THE SETTING OF TIME STANDARDS FOR THE PRODUCTION AND SEWING OPERATIONS

    Directory of Open Access Journals (Sweden)

    SECAN Cristina

    2014-05-01

    Full Text Available This paper presents the technological process of manufacture of a shoe for women in IL system in order to establish the time and the production norm in the processing-sewing procedure. The sequence of operations is presented in a case study that analyzed how can be obtained the upper assembly of a footwear product that later becomes integral part into the finished product. Drawing up the technological process is done considering both the manual operations and the manual-mechanical operations for processing and assembling the parts that make the whole upper assembly by gluing the parts, by seaming and securing the joints. The type of equipment chosen to carry out operations is influencing through its productivity the necessary material calculated and hence the labour force required. The amount of time consists of time needed for preparation-finishing time, operative time, time of working place service and time of regulated interruptions. These periods of times were determined basically by timing assistance of the manufacturing process throughout its development. Production norm is calculated on the basis of the standard time, taking into account that it represents the amount of products manufactured in a work shift In order to improve the process by reducing the time of production and the number of workers engaged we are considering the automation of the manufacturing process by using modern methods using laser cutting or cutting under running water, automatic sewing machines, strip conveyor belts with pace imposed etc.

  7. A HARDWARE SUPPORTED OPERATING SYSTEM KERNEL FOR EMBEDDED HARD REAL-TIME APPLICATIONS

    NARCIS (Netherlands)

    COLNARIC, M; HALANG, WA; TOL, RM

    1994-01-01

    The concept of the kernel, i.e. the time critical part of a real-time operating system, and its dedicated co-processor, especially tailored for embedded applications, are presented. The co-processor acts as a system controller and operates in conjunction with one or more conventional processors in

  8. Response Times of Operators in a Control Room

    DEFF Research Database (Denmark)

    Platz, O.; Rasmussen, Jens; Skanborg, Preben Zacho

    A statistical analysis was made of operator response times recorded in the control room of a research reactor during the years 1972-1974. A homogeneity test revealed that the data consist of a mixture of populations. A small but statistically significant difference is found between day and night...

  9. Real-Time Integrated Re-scheduling for Tramway Operations

    NARCIS (Netherlands)

    Cheung, Kam-Fung; Kuo, Yong-Hong; Lai, S.W.; Leung, Janny M.Y.

    2018-01-01

    Our work aims to develop practical solution approaches for real-time dispatch of crews and vehicles for disruption management. The practical motivation for our research arose from the operations of a public tramway system in Hong Kong. The tram system shares the road with other vehicular traffic in

  10. Intraneural hemangioma of the median nerve: A case report

    Directory of Open Access Journals (Sweden)

    Sevinç Teoman

    2008-02-01

    Full Text Available Abstract Hemangiomas of the median nerve are very rare and, so far, only ten cases of intraneural hemangioma of this nerve have been reported in the literature. We present a case of 14-year-old girl who had a soft tissue mass in the region of the left wrist with signs and symptoms of carpal tunnel syndrome. Total removal of the mass was achieved using microsurgical epineural and interfasicular dissection. The symptoms were relieved completely, after this procedure, without any neurologic deficit. On follow-up two years later, no recurrence was observed. Whenever a child or young adult patient presents with CTS the possibility of a hemangioma involving the median nerve should be kept in mind in the differential diagnosis.

  11. Mixed - mode Operating System for Real - time Performance

    Directory of Open Access Journals (Sweden)

    Hasan M. M.

    2017-11-01

    Full Text Available The purpose of the mixed-mode system research is to handle devices with the accuracy of real-time systems and at the same time, having all the benefits and facilities of a matured Graphic User Interface(GUIoperating system which is typicallynon-real-time. This mixed-mode operating system comprising of a real-time portion and a non-real-time portion was studied and implemented to identify the feasibilities and performances in practical applications (in the context of scheduled the real-time events. In this research an i8751 microcontroller-based hardware was used to measure the performance of the system in real-time-only as well as non-real-time-only configurations. The real-time portion is an 486DX-40 IBM PC system running under DOS-based real-time kernel and the non-real-time portion is a Pentium IIIbased system running under Windows NT. It was found that mixed-mode systems performed as good as a typical real-time system and in fact, gave many additional benefits such as simplified/modular programming and load tolerance.

  12. Off-Policy Reinforcement Learning: Optimal Operational Control for Two-Time-Scale Industrial Processes.

    Science.gov (United States)

    Li, Jinna; Kiumarsi, Bahare; Chai, Tianyou; Lewis, Frank L; Fan, Jialu

    2017-12-01

    Industrial flow lines are composed of unit processes operating on a fast time scale and performance measurements known as operational indices measured at a slower time scale. This paper presents a model-free optimal solution to a class of two time-scale industrial processes using off-policy reinforcement learning (RL). First, the lower-layer unit process control loop with a fast sampling period and the upper-layer operational index dynamics at a slow time scale are modeled. Second, a general optimal operational control problem is formulated to optimally prescribe the set-points for the unit industrial process. Then, a zero-sum game off-policy RL algorithm is developed to find the optimal set-points by using data measured in real-time. Finally, a simulation experiment is employed for an industrial flotation process to show the effectiveness of the proposed method.

  13. Brain malformation in single median maxillary central incisor

    DEFF Research Database (Denmark)

    Kjaer, I; Wagner, Aa; Thomsen, L L

    2009-01-01

    Clinical and radiographic examinations and MR scan of a 12-year-old girl with SMMCI (single median maxillary central incisor) showed impaired growth and a midline defect involving the central incisor, cranium and the midline structures in the brain, falx cerebri and pituitary gland. She had a sev...

  14. TWOS - TIME WARP OPERATING SYSTEM, VERSION 2.5.1

    Science.gov (United States)

    Bellenot, S. F.

    1994-01-01

    The Time Warp Operating System (TWOS) is a special-purpose operating system designed to support parallel discrete-event simulation. TWOS is a complete implementation of the Time Warp mechanism, a distributed protocol for virtual time synchronization based on process rollback and message annihilation. Version 2.5.1 supports simulations and other computations using both virtual time and dynamic load balancing; it does not support general time-sharing or multi-process jobs using conventional message synchronization and communication. The program utilizes the underlying operating system's resources. TWOS runs a single simulation at a time, executing it concurrently on as many processors of a distributed system as are allocated. The simulation needs only to be decomposed into objects (logical processes) that interact through time-stamped messages. TWOS provides transparent synchronization. The user does not have to add any more special logic to aid in synchronization, nor give any synchronization advice, nor even understand much about how the Time Warp mechanism works. The Time Warp Simulator (TWSIM) subdirectory contains a sequential simulation engine that is interface compatible with TWOS. This means that an application designer and programmer who wish to use TWOS can prototype code on TWSIM on a single processor and/or workstation before having to deal with the complexity of working on a distributed system. TWSIM also provides statistics about the application which may be helpful for determining the correctness of an application and for achieving good performance on TWOS. Version 2.5.1 has an updated interface that is not compatible with 2.0. The program's user manual assists the simulation programmer in the design, coding, and implementation of discrete-event simulations running on TWOS. The manual also includes a practical user's guide to the TWOS application benchmark, Colliding Pucks. TWOS supports simulations written in the C programming language. It is designed

  15. Applicable value of real time interventional ultrasound guidance in family planning reproduction operation

    International Nuclear Information System (INIS)

    Wu Guoping; Zou Dongfang; Sun Jian; Dong Weihua

    2007-01-01

    Objective: To determine the clinical value of real time interventional ultrasound guidance in family planning reproduction operation. Methods: Under the guidance of ultrasound monitoring, 522 cases with high risk and difficult uterine operation were undertaken in our department. Results: The abdominal endoscopic contraceptive uterine operation under real time ultrasound monitoring was carried out for 522 cases in 4 years, with successful rates for high risk pregnancy as 287/289 cases, high risk troublesome withdrawal of contraceptive ring as 129/130 cases and puzzling uterine operation as 103/103 cases. The total successful rate reached 99.42%, without uterine rupture and other complications. Conclusion: The former complex, blind and difficult uterine operations turn to be simple, safe and reliable under the guidance of real time ultrasound. (authors)

  16. Tunneling time through a barrier using the tempus operator

    Energy Technology Data Exchange (ETDEWEB)

    Kobe, Donald H.; Aguilera-Navarro, Valdir C. [North Texas Univ., Denton, TX (United States). Dept. of Physics

    1996-11-01

    The time a particle spends in a classically forbidden region of a potential barrier is expressed as an expectation value of the time operator in that region. Classically, time is canonically conjugate to the energy and is equal to the time a conservative system. The tunneling time is calculated by this approach for a rectangular barrier, which gives a complex time. The imaginary part of the time is non negative, so it is interpreted as a tunneling time. The real part gives a negative value for some values of the parameters, and is therefore rejected because it violates causality. This tunneling time is compared with other tunneling times that have been suggested by also calculating them for the rectangular barrier. 58 refs., 7 figs.

  17. Tunneling time through a barrier using the tempus operator

    International Nuclear Information System (INIS)

    Kobe, Donald H.; Aguilera-Navarro, Valdir C.

    1996-11-01

    The time a particle spends in a classically forbidden region of a potential barrier is expressed as an expectation value of the time operator in that region. Classically, time is canonically conjugate to the energy and is equal to the time a conservative system. The tunneling time is calculated by this approach for a rectangular barrier, which gives a complex time. The imaginary part of the time is non negative, so it is interpreted as a tunneling time. The real part gives a negative value for some values of the parameters, and is therefore rejected because it violates causality. This tunneling time is compared with other tunneling times that have been suggested by also calculating them for the rectangular barrier. 58 refs., 7 figs

  18. Use of an operating microscope during spine surgery is associated with minor increases in operating room times and no increased risk of infection.

    Science.gov (United States)

    Basques, Bryce A; Golinvaux, Nicholas S; Bohl, Daniel D; Yacob, Alem; Toy, Jason O; Varthi, Arya G; Grauer, Jonathan N

    2014-10-15

    Retrospective database review. To evaluate whether microscope use during spine procedures is associated with increased operating room times or increased risk of infection. Operating microscopes are commonly used in spine procedures. It is debated whether the use of an operating microscope increases operating room time or confers increased risk of infection. The American College of Surgeons National Surgical Quality Improvement Program database, which includes data from more than 370 participating hospitals, was used to identify patients undergoing elective spinal procedures with and without the use of an operating microscope for the years 2011 and 2012. Bivariate and multivariate linear regressions were used to test the association between microscope use and operating room times. Bivariate and multivariate logistic regressions were similarly conducted to test the association between microscope use and infection occurrence within 30 days of surgery. A total of 23,670 elective spine procedures were identified, of which 2226 (9.4%) used an operating microscope. The average patient age was 55.1±14.4 years. The average operative time (incision to closure) was 125.7±82.0 minutes.Microscope use was associated with minor increases in preoperative room time (+2.9 min, P=0.013), operative time (+13.2 min, Pmicroscope and nonmicroscope groups for occurrence of any infection, superficial surgical site infection, deep surgical site infection, organ space infection, or sepsis/septic shock, regardless of surgery type. We did not find operating room times or infection risk to be significant deterrents for use of an operating microscope during spine surgery. 3.

  19. Dose dependency of the frequency of micronucleated binucleated clone cells and of division related median clone sizes difference. Pt. 2

    International Nuclear Information System (INIS)

    Hagemann, G,; Kreczik, A.; Treichel, M.

    1996-01-01

    Following irradiation of the progenitor cells the clone growth of CHO cells decreases as a result of cell losses. Lethally acting expressions of micronuclei are produced by heritable lethal mutations. The dependency of the frequency of micronucleated binucleated clone cells and of the median clone sizes difference on the radiation dose was measured and compared to non-irradiated controls. Using the cytokinesis-block-micronucleus-method binucleated cells with micronuclei were counted as ratio of all binucleated cells within a clone size distribution. This ratio (shortened: micronucleus yield) was determined for all clone size distributions, which had been exposed to different irradiation doses and incubation times. The micronucleus yields were compared to the corresponding median clone sizes differences. The micronucleus yield is linearly dependent on the dose and is independent of the incubation time. The same holds true for the division related median clone sizes difference, which as a result is also linearly dependent on the micronucleus yield. Due to the inevitably errors of the cell count of micronucleated binucleated cells, an automatic measurement of the median clone sizes differences is the preferred method for evaluation of cellular radiation sensitivity for heritable lethal mutations. This value should always be determined in addition, if clone survival fractions are used as predictive test because it allows for an estimation of the remission probability of surviving cells. (orig.) [de

  20. A new continuous-time formulation for scheduling crude oil operations

    International Nuclear Information System (INIS)

    Reddy, P. Chandra Prakash; Karimi, I.A.; Srinivasan, R.

    2004-01-01

    In today's competitive business climate characterized by uncertain oil markets, responding effectively and speedily to market forces, while maintaining reliable operations, is crucial to a refinery's bottom line. Optimal crude oil scheduling enables cost reduction by using cheaper crudes intelligently, minimizing crude changeovers, and avoiding ship demurrage. So far, only discrete-time formulations have stood up to the challenge of this important, nonlinear problem. A continuous-time formulation would portend numerous advantages, however, existing work in this area has just begun to scratch the surface. In this paper, we present the first complete continuous-time mixed integer linear programming (MILP) formulation for the short-term scheduling of operations in a refinery that receives crude from very large crude carriers via a high-volume single buoy mooring pipeline. This novel formulation accounts for real-world operational practices. We use an iterative algorithm to eliminate the crude composition discrepancy that has proven to be the Achilles heel for existing formulations. While it does not guarantee global optimality, the algorithm needs only MILP solutions and obtains excellent maximum-profit schedules for industrial problems with up to 7 days of scheduling horizon. We also report the first comparison of discrete- vs. continuous-time formulations for this complex problem. (Author)

  1. Time parallelization of advanced operation scenario simulations of ITER plasma

    International Nuclear Information System (INIS)

    Samaddar, D; Casper, T A; Kim, S H; Houlberg, W A; Berry, L A; Elwasif, W R; Batchelor, D

    2013-01-01

    This work demonstrates that simulations of advanced burning plasma operation scenarios can be successfully parallelized in time using the parareal algorithm. CORSICA -an advanced operation scenario code for tokamak plasmas is used as a test case. This is a unique application since the parareal algorithm has so far been applied to relatively much simpler systems except for the case of turbulence. In the present application, a computational gain of an order of magnitude has been achieved which is extremely promising. A successful implementation of the Parareal algorithm to codes like CORSICA ushers in the possibility of time efficient simulations of ITER plasmas.

  2. Planning the City Logistics Terminal Location by Applying the Green p-Median Model and Type-2 Neurofuzzy Network.

    Science.gov (United States)

    Pamučar, Dragan; Vasin, Ljubislav; Atanasković, Predrag; Miličić, Milica

    2016-01-01

    The paper herein presents green p-median problem (GMP) which uses the adaptive type-2 neural network for the processing of environmental and sociological parameters including costs of logistics operators and demonstrates the influence of these parameters on planning the location for the city logistics terminal (CLT) within the discrete network. CLT shows direct effects on increment of traffic volume especially in urban areas, which further results in negative environmental effects such as air pollution and noise as well as increased number of urban populations suffering from bronchitis, asthma, and similar respiratory infections. By applying the green p-median model (GMM), negative effects on environment and health in urban areas caused by delivery vehicles may be reduced to minimum. This model creates real possibilities for making the proper investment decisions so as profitable investments may be realized in the field of transport infrastructure. The paper herein also includes testing of GMM in real conditions on four CLT locations in Belgrade City zone.

  3. Planning the City Logistics Terminal Location by Applying the Green p-Median Model and Type-2 Neurofuzzy Network

    Directory of Open Access Journals (Sweden)

    Dragan Pamučar

    2016-01-01

    Full Text Available The paper herein presents green p-median problem (GMP which uses the adaptive type-2 neural network for the processing of environmental and sociological parameters including costs of logistics operators and demonstrates the influence of these parameters on planning the location for the city logistics terminal (CLT within the discrete network. CLT shows direct effects on increment of traffic volume especially in urban areas, which further results in negative environmental effects such as air pollution and noise as well as increased number of urban populations suffering from bronchitis, asthma, and similar respiratory infections. By applying the green p-median model (GMM, negative effects on environment and health in urban areas caused by delivery vehicles may be reduced to minimum. This model creates real possibilities for making the proper investment decisions so as profitable investments may be realized in the field of transport infrastructure. The paper herein also includes testing of GMM in real conditions on four CLT locations in Belgrade City zone.

  4. Operator-normalized quantum arrival times in the presence of interactions

    International Nuclear Information System (INIS)

    Hegerfeldt, G.C.; Seidel, D.; Muga, J.G.; Navarro, B.

    2004-01-01

    We model ideal arrival-time measurements for free quantum particles and for particles subject to an external interaction by means of a narrow and weak absorbing potential. This approach is related to the operational approach of measuring the first photon emitted from a two-level atom illuminated by a laser. By operator normalizing the resulting time-of-arrival distribution, a distribution is obtained which for freely moving particles not only recovers the axiomatically derived distribution of Kijowski for states with purely positive momenta but is also applicable to general momentum components. For particles interacting with a square barrier the mean arrival time and corresponding 'tunneling time' obtained at the transmission side of the barrier become independent of the barrier width (Hartman effect) for arbitrarily wide barriers, i.e., without the transition to the ultraopaque, classical-like regime dominated by wave packet components above the barrier

  5. A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Lorraine [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia); Cox, Jennifer [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia); Faculty of Health Sciences, University of Sydney, Sydney, New South Wales (Australia); Morgia, Marita [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia); Atyeo, John [Faculty of Health Sciences, University of Sydney, Sydney, New South Wales (Australia); Lamoury, Gillian [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia)

    2015-09-15

    The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 days post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm{sup 3} (4–118) and CT2ch: median 16 cm{sup 3}, (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence.

  6. A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time

    International Nuclear Information System (INIS)

    Lewis, Lorraine; Cox, Jennifer; Morgia, Marita; Atyeo, John; Lamoury, Gillian

    2015-01-01

    The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 days post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm 3 (4–118) and CT2ch: median 16 cm 3 , (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence

  7. Developing infrared array controller with software real time operating system

    Science.gov (United States)

    Sako, Shigeyuki; Miyata, Takashi; Nakamura, Tomohiko; Motohara, Kentaro; Uchimoto, Yuka Katsuno; Onaka, Takashi; Kataza, Hirokazu

    2008-07-01

    Real-time capabilities are required for a controller of a large format array to reduce a dead-time attributed by readout and data transfer. The real-time processing has been achieved by dedicated processors including DSP, CPLD, and FPGA devices. However, the dedicated processors have problems with memory resources, inflexibility, and high cost. Meanwhile, a recent PC has sufficient resources of CPUs and memories to control the infrared array and to process a large amount of frame data in real-time. In this study, we have developed an infrared array controller with a software real-time operating system (RTOS) instead of the dedicated processors. A Linux PC equipped with a RTAI extension and a dual-core CPU is used as a main computer, and one of the CPU cores is allocated to the real-time processing. A digital I/O board with DMA functions is used for an I/O interface. The signal-processing cores are integrated in the OS kernel as a real-time driver module, which is composed of two virtual devices of the clock processor and the frame processor tasks. The array controller with the RTOS realizes complicated operations easily, flexibly, and at a low cost.

  8. Design of real-time operating system software

    International Nuclear Information System (INIS)

    Stafford, D.L.; Hulbert, A.J.

    1976-01-01

    Design of real-time data collection and control systems is complicated by problems not found in common sequential programming projects. Timing and synchronization are critical; data collection equipment is often completely foreign to mainframe programming facilities; operating system response to real-time events may be far too slow or too cumbersome. The philosophy at the Inhalation Toxicology Research Institute (ITRI) is to allow the investigators to do as much of their own programming as possible. Inasmuch as programming is not their primary responsibility or area of training, it is unreasonable to assume that they are familiar with the subtleties involved. The problem, therefore, has been to develop a system whereby investigators are able, with minimal consultation, to write, modify and otherwise maintain their own data collection and control programs and to do so with a minimum of destructive interaction with other data collection and control tasks

  9. Identification of human operator performance models utilizing time series analysis

    Science.gov (United States)

    Holden, F. M.; Shinners, S. M.

    1973-01-01

    The results of an effort performed by Sperry Systems Management Division for AMRL in applying time series analysis as a tool for modeling the human operator are presented. This technique is utilized for determining the variation of the human transfer function under various levels of stress. The human operator's model is determined based on actual input and output data from a tracking experiment.

  10. PERBANDINGAN TRANSFORMASI BOX-COX DAN REGRESI KUANTIL MEDIAN DALAM MENGATASI HETEROSKEDASTISITAS

    Directory of Open Access Journals (Sweden)

    NI WAYAN YUNI CAHYANI

    2015-01-01

    Full Text Available Ordinary least square (OLS is a method that can be used to estimate the parameter in linear regression analysis. There are some assumption which should be satisfied on OLS, one of this assumption is homoscedasticity, that is the variance of error is constant. If variance of the error is unequal that so-called heteroscedasticity. The presence heteroscedasticity can cause estimation with OLS becomes inefficient. Therefore, heteroscedasticity shall be overcome. There are some method that can used to overcome heteroscedasticity, two among those are Box-Cox power transformation and median quantile regression. This research compared Box-Cox power transformation and median quantile regression to overcome heteroscedasticity. Applied Box-Cox power transformation on OLS result ????2point are greater, smaller RMSE point and confidencen interval more narrow, therefore can be concluded that applied of Box-Cox power transformation on OLS better of median quantile regression to overcome heteroscedasticity.

  11. PERBANDINGAN TRANSFORMASI BOX-COX DAN REGRESI KUANTIL MEDIAN DALAM MENGATASI HETEROSKEDASTISITAS

    Directory of Open Access Journals (Sweden)

    NI WAYAN YUNI CAHYANI

    2015-03-01

    Full Text Available Ordinary least square (OLS is a method that can be used to estimate the parameter in linear regression analysis. There are some assumption which should be satisfied on OLS, one of this assumption is homoscedasticity, that is the variance of error is constant. If variance of the error is unequal that so-called heteroscedasticity. The presence heteroscedasticity can cause estimation with OLS becomes inefficient. Therefore, heteroscedasticity shall be overcome. There are some method that can used to overcome heteroscedasticity, two among those are Box-Cox power transformation and median quantile regression. This research compared Box-Cox power transformation and median quantile regression to overcome heteroscedasticity. Applied Box-Cox power transformation on OLS result ????2point are greater, smaller RMSE point and confidencen interval more narrow, therefore can be concluded that applied of Box-Cox power transformation on OLS better of median quantile regression to overcome heteroscedasticity.

  12. Effect of Individual Surgeons and Anesthesiologists on Operating Room Time

    NARCIS (Netherlands)

    van Eijk, Ruben P A; van Veen-Berkx, Elizabeth; Kazemier, Geert; Eijkemans, Marinus J C

    BACKGROUND:: Variability in operating room (OR) time causes overutilization and underutilization of the available ORs. There is evidence that for a given type of procedure, the surgeon is the major source of variability in OR time. The primary aim was to quantify the variability between surgeons and

  13. A Randomized Trial to Assess the Contribution of a Novel Thorax Support Vest (Corset) in Preventing Mechanical Complications of Median Sternotomy.

    Science.gov (United States)

    Caimmi, Philippe P; Sabbatini, Maurizio; Kapetanakis, Emmanouil I; Cantone, Silvia; Ferraz, Marcus V; Cannas, Mario; Tesler, Ugo F

    2017-06-01

    Mechanical complications of median sternotomy may cause significant morbidity and mortality in cardiac surgical patients. This study was aimed at assessing the role of Posthorax support vest (Epple, Inc., Vienna, Austria) in the prevention of sternal complications and the improvement of anatomical healing in patients at high risk for mechanical sternal dehiscence after cardiac surgery by mean of median sternotomy. A prospective, randomized, study was performed and 310 patients with predisposing factors for sternal dehiscence after sternotomy for cardiac surgery were included. The patients were divided into two groups: patients who received the Posthorax support vest after surgery, and patients who did not. Primary variables assessed included the incidence of mechanical sternal complications, the quality of sternal healing, the rate of re-operation, the duration of hospitalization, rate and duration of hospital, re-admission for sternal complications. Secondary variables assessed were the post-operative pain, the number of requests for supplemental analgesia and the quality of life measured by means of the EQ-5D format. Patients using vest demonstrated a lower incidence of mechanical sternal complications, a better anatomical sternum healing, lower hospital stay, no re-operations for sternal dehiscence before discharge and lower re-admissions for mechanical sternal complication. In addition, patients using a vest reported a better quality of life with better freedom from limitations in mobility, self-care, and pain. Our findings demonstrate that the use of the Posthorax vest reduces post-sternotomy mechanical complications and improves the healing of the sternotomy, the clinical course, and the post-operative quality of life.

  14. Ignition and time-dependent fractional power operation of tokamak reactors

    International Nuclear Information System (INIS)

    Vold, E.L.; Mau, T.K.; Conn, R.W.

    1986-01-01

    The eventual utilization of a tokamak fusion reactor for commercial power necessitates a thorough understanding of the operational requirements at full and fractional power levels and during transitions from one operating level to another. In this study we examine the role of burn control in maintaining the reactor plasma at equilibrium to avoid thermal runaway during fractional power operation. Because these requirements rely so heavily on the assumptions that govern the plasma transport, this study focuses on time-dependent analyses and a comparison of ignition requirements using a range of energy confinement

  15. Real-time operations intelligence from the user perspective

    Energy Technology Data Exchange (ETDEWEB)

    Kharbat, Fayez [Saudi Aramco, Dhahran (Saudi Arabia)

    2004-07-01

    Running a refinery or a chemical plant is a complex business. Planning and scheduling, process control and maintenance require dedicated, multifaceted solutions necessitating highly trained and experienced users. The inevitable system and user specialization results in the proliferation of disparate data sources, incoherent information, inconsistent decisions and the failure to realize corporate objectives - until today. IndX Software Corporation is the de facto market-leading provider of operations intelligence solutions. IndX's XHQ{sup TM} Real-time Operations Intelligence solutions have been selected by many of the world's major corporations in their quest for Operational Excellence and IndX is currently engaged in more than 50 maximizedROI{sup TM} deployments around the world. This paper describes the thinking and technology behind XHQ and the implementation methodology typically employed in deploying an XHQ solution enterprise-wide. This paper will also provide examples of the benefits that users have realized from their implementation of XHQ. (author)

  16. Using mean duration and variation of procedure times to plan a list of surgical operations to fit into the scheduled list time.

    Science.gov (United States)

    Pandit, Jaideep J; Tavare, Aniket

    2011-07-01

    It is important that a surgical list is planned to utilise as much of the scheduled time as possible while not over-running, because this can lead to cancellation of operations. We wished to assess whether, theoretically, the known duration of individual operations could be used quantitatively to predict the likely duration of the operating list. In a university hospital setting, we first assessed the extent to which the current ad-hoc method of operating list planning was able to match the scheduled operating list times for 153 consecutive historical lists. Using receiver operating curve analysis, we assessed the ability of an alternative method to predict operating list duration for the same operating lists. This method uses a simple formula: the sum of individual operation times and a pooled standard deviation of these times. We used the operating list duration estimated from this formula to generate a probability that the operating list would finish within its scheduled time. Finally, we applied the simple formula prospectively to 150 operating lists, 'shadowing' the current ad-hoc method, to confirm the predictive ability of the formula. The ad-hoc method was very poor at planning: 50% of historical operating lists were under-booked and 37% over-booked. In contrast, the simple formula predicted the correct outcome (under-run or over-run) for 76% of these operating lists. The calculated probability that a planned series of operations will over-run or under-run was found useful in developing an algorithm to adjust the planned cases optimally. In the prospective series, 65% of operating lists were over-booked and 10% were under-booked. The formula predicted the correct outcome for 84% of operating lists. A simple quantitative method of estimating operating list duration for a series of operations leads to an algorithm (readily created on an Excel spreadsheet, http://links.lww.com/EJA/A19) that can potentially improve operating list planning.

  17. Impulse Noise Cancellation of Medical Images Using Wavelet Networks and Median Filters

    Science.gov (United States)

    Sadri, Amir Reza; Zekri, Maryam; Sadri, Saeid; Gheissari, Niloofar

    2012-01-01

    This paper presents a new two-stage approach to impulse noise removal for medical images based on wavelet network (WN). The first step is noise detection, in which the so-called gray-level difference and average background difference are considered as the inputs of a WN. Wavelet Network is used as a preprocessing for the second stage. The second step is removing impulse noise with a median filter. The wavelet network presented here is a fixed one without learning. Experimental results show that our method acts on impulse noise effectively, and at the same time preserves chromaticity and image details very well. PMID:23493998

  18. Nuorten sosiaalisen median käyttö seurustelusuhteissa : "Onksiul snappii, kikkii tai whatsappii?"

    OpenAIRE

    Pöllänen, Kati

    2016-01-01

    Tässä opinnäytetyössä tutkittiin nuorten sosiaalisen median käyttöä seurustelusuhteissa. Seurustelusuhteella tarkoitetaan kahden toisistaan pitävän ihmisen romanttista suhdetta. Työssä tarkasteltiin keskinuorten ja myöhäisnuorten käyttämiä sosiaalisen median sovelluksia, käyttömääriä ja –tapoja. Lisäksi selvitettiin, millainen rooli sosiaalisella medialla on seurustelusuhteen eri vaiheissa. Työssä tutustuttiin nuorten sosiaalisen median käyttöön kenttätutkimuksella, jossa nu...

  19. Does antegrade JJ stenting affect the total operative time during laparoscopic pyeloplasty?

    Science.gov (United States)

    Bolat, Mustafa Suat; Çınar, Önder; Akdeniz, Ekrem

    2017-12-01

    We aimed to show the effect of retrograde JJ stenting and intraoperative antegrade JJ stenting techniques on operative time in patients who underwent laparoscopic pyeloplasty. A total of 34 patients were retrospectively investigated (15 male and 19 female) with ureteropelvic junction obstruction. Of the patients stentized under local anesthesia preoperatively, as a part of surgery, 15 were retrogradely stentized at the beginning of the procedure (Group 1), and 19 were antegradely stentized during the procedure (Group 2). A transperitoneal dismembered pyeloplasty technique was performed in all patients. The two groups were retrospectively compared in terms of complications, the mean total operative time, and the mean stenting times. The mean ages of the patients were 31.5±15.5 and 33.2±15.5 years (p=0.09), and the mean body mass indexes were 25.8±5.6 and 26.2.3±8.4 kg/m 2 in Group 1 and Group 2, respectively. The mean total operative times were 128.9±38.9 min and 112.7±21.9 min (p=0.04); the mean stenting times were 12.6±5.4 min and 3.5±2.4 min (p=0.02); and the mean rates of catheterization-to-total surgery times were 0.1 and 0.03 (p=0.01) in Group 1 and 2, respectively. The mean hospital stays and the mean anastomosis times were similar between the two groups (p>0.05). Antegrade JJ stenting during laparoscopic pyeloplasty significantly decreased the total operative time.

  20. Real-time operation without a real-time operating system for instrument control and data acquisition

    Science.gov (United States)

    Klein, Randolf; Poglitsch, Albrecht; Fumi, Fabio; Geis, Norbert; Hamidouche, Murad; Hoenle, Rainer; Looney, Leslie; Raab, Walfried; Viehhauser, Werner

    2004-09-01

    We are building the Field-Imaging Far-Infrared Line Spectrometer (FIFI LS) for the US-German airborne observatory SOFIA. The detector read-out system is driven by a clock signal at a certain frequency. This signal has to be provided and all other sub-systems have to work synchronously to this clock. The data generated by the instrument has to be received by a computer in a timely manner. Usually these requirements are met with a real-time operating system (RTOS). In this presentation we want to show how we meet these demands differently avoiding the stiffness of an RTOS. Digital I/O-cards with a large buffer separate the asynchronous working computers and the synchronous working instrument. The advantage is that the data processing computers do not need to process the data in real-time. It is sufficient that the computer can process the incoming data stream on average. But since the data is read-in synchronously, problems of relating commands and responses (data) have to be solved: The data is arriving at a fixed rate. The receiving I/O-card buffers the data in its buffer until the computer can access it. To relate the data to commands sent previously, the data is tagged by counters in the read-out electronics. These counters count the system's heartbeat and signals derived from that. The heartbeat and control signals synchronous with the heartbeat are sent by an I/O-card working as pattern generator. Its buffer gets continously programmed with a pattern which is clocked out on the control lines. A counter in the I/O-card keeps track of the amount of pattern words clocked out. By reading this counter, the computer knows the state of the instrument or knows the meaning of the data that will arrive with a certain time-tag.

  1. Schroedinger operators - geometric estimates in terms of the occupation time

    International Nuclear Information System (INIS)

    Demuth, M.; Kirsch, W.; McGillivray, I.

    1995-01-01

    The difference of Schroedinger and Dirichlet semigroups is expressed in terms of the Laplace transform of the Brownian motion occupation time. This implies quantitative upper and lower bounds for the operator norms of the corresponding resolvent differences. One spectral theoretical consequence is an estimate for the eigenfunction for a Schroedinger operator in a ball where the potential is given as a cone indicator function. 12 refs

  2. Median sternotomy for double lung transplantation with cardiopulmonary bypass in seven consecutive patients

    DEFF Research Database (Denmark)

    Kohno, Mitsutomo; Steinbrüchel, Daniel A

    2012-01-01

    We describe our technique of using median sternotomy to perform double lung transplantations with cardiopulmonary bypass. By sparing the respiratory muscles, median sternotomy is probably less invasive and preserves lung function. Furthermore, it causes less long-term discomfort than intercostal...

  3. Characterization of melatonin binding sites in the Harderian gland and median eminence of the rat

    International Nuclear Information System (INIS)

    Lopez-Gonzalez, M.A.; Calvo, J.R.; Rubio, A.; Goberna, R.; Guerrero, J.M.

    1991-01-01

    The characterization of specific melatonin binding sites in the Harderian gland (HG) and median eminence (ME) of the rat was studied using [ 125 I]melatonin. Binding of melatonin to membrane crude preparations of both tissues was dependent on time and temperature. Thus, maximal binding was obtained at 37 degree C after 30-60 min incubation. Binding was also dependent on protein concentration. The specific binding of [ 125 I]melatonin was saturable, exhibiting only the class of binding sites in both tissues. The dissociation constants (Kd) were 170 and 190 pM for ME and HG, respectively. The concentration of the binding sites in ME was 8 fmol/mg protein, and in the HG 4 fmol/mg protein. In competition studies, binding of [ 125 I]melatonin to ME or HG was inhibited by increasing concentration of native melatonin; 50% inhibition was observed at about 702 and 422 nM for ME and HG, respectively. Additionally, the [ 125 I]melatonin binding to the crude membranes was not affected by the addition of different drugs such as norepinephrine, isoproterenol, phenylephrine, propranolol, or prazosin. The results confirm the presence of melatonin binding sites in median eminence and show, for the first time, the existence of melatonin binding sites in the Harderian gland

  4. A virtual reality-based method of decreasing transmission time of visual feedback for a tele-operative robotic catheter operating system.

    Science.gov (United States)

    Guo, Jin; Guo, Shuxiang; Tamiya, Takashi; Hirata, Hideyuki; Ishihara, Hidenori

    2016-03-01

    An Internet-based tele-operative robotic catheter operating system was designed for vascular interventional surgery, to afford unskilled surgeons the opportunity to learn basic catheter/guidewire skills, while allowing experienced physicians to perform surgeries cooperatively. Remote surgical procedures, limited by variable transmission times for visual feedback, have been associated with deterioration in operability and vascular wall damage during surgery. At the patient's location, the catheter shape/position was detected in real time and converted into three-dimensional coordinates in a world coordinate system. At the operation location, the catheter shape was reconstructed in a virtual-reality environment, based on the coordinates received. The data volume reduction significantly reduced visual feedback transmission times. Remote transmission experiments, conducted over inter-country distances, demonstrated the improved performance of the proposed prototype. The maximum error for the catheter shape reconstruction was 0.93 mm and the transmission time was reduced considerably. The results were positive and demonstrate the feasibility of remote surgery using conventional network infrastructures. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Implementation and Operational Research: A Time-Motion Analysis of HIV Transmission Prevention Counseling and Antiretroviral Adherence Messages in Western Kenya.

    Science.gov (United States)

    Were, Martin C; Kessler, Jason; Shen, Changyu; Sidle, John; Macharia, Stephen; Lizcano, John; Siika, Abraham; Wools-Kaloustian, Kara; Kurth, Ann

    2015-08-01

    Shortages of health workers and large number of HIV-infected persons in Africa mean that time to provide antiretroviral therapy (ART) adherence and other messages to patients is limited. Using time-motion methodology, we documented the intensity and nature of counseling delivered to patients. The study was conducted at a rural and an urban HIV clinic in western Kenya. We recorded all activities of 190 adult patients on ART during their return clinic visits to assess type, frequency, and duration of counseling messages. Mean visit length for patients at the rural clinic was 44.5 (SD = 27.9) minutes and at urban clinic was 78.2 (SD = 42.1) minutes. Median time spent receiving any counseling during a visit was 4.07 minutes [interquartile range (IQR), 1.57-7.33] at rural and 3.99 (IQR, 2.87-6.25) minutes at urban, representing 11% and 8% of total mean visit time, respectively. Median time patients received ART adherence counseling was 1.29 (IQR, 0.77-2.83) minutes at rural and 1.76 (IQR, 1.23-2.83) minutes at urban (P = 0.001 for difference). Patients received a median time of 0.18 (0-0.72) minutes at rural and 0.28 (IQR, 0-0.67) minutes at urban clinic of counseling regarding contraception and pregnancy. Most patients in the study did not receive any counseling regarding alcohol/substance use, emerging risks for ongoing HIV transmission. Although ART adherence was discussed with most patients, time was limited. Reproductive counseling was provided to only half of the patients, and "positive prevention" messaging was minimal. There are strategic opportunities to enhance counseling and information received by clients within HIV programs in resource-limited settings.

  6. A case of fibrolipomatous hamartoma of the median nerve with macrodactyly

    Directory of Open Access Journals (Sweden)

    Sathish Arakeri

    2012-07-01

    Full Text Available Fibrolipomatous hamartoma of nerve is a tumor-like lipomatous process principally involving affecting young persons. The median nerve is most commonly affectedinvolved. The lesion is characterized by a soft slowly growing mass, surrounding and infiltrating major nerves and their branches. It may cause symptoms of compression neuropathy and is associated with macrodactyly in one third of cases. Here, we present a case of Fibrolipomatous hamartoma of nerve in the wrist of a young man arising from median nerve. Debulking of the tumour was performed.

  7. ISS Operations Cost Reductions Through Automation of Real-Time Planning Tasks

    Science.gov (United States)

    Hall, Timothy A.

    2011-01-01

    In 2008 the Johnson Space Center s Mission Operations Directorate (MOD) management team challenged their organization to find ways to reduce the costs of International Space station (ISS) console operations in the Mission Control Center (MCC). Each MOD organization was asked to identify projects that would help them attain a goal of a 30% reduction in operating costs by 2012. The MOD Operations and Planning organization responded to this challenge by launching several software automation projects that would allow them to greatly improve ISS console operations and reduce staffing and operating costs. These projects to date have allowed the MOD Operations organization to remove one full time (7 x 24 x 365) ISS console position in 2010; with the plan of eliminating two full time ISS console support positions by 2012. This will account for an overall 10 EP reduction in staffing for the Operations and Planning organization. These automation projects focused on utilizing software to automate many administrative and often repetitive tasks involved with processing ISS planning and daily operations information. This information was exchanged between the ground flight control teams in Houston and around the globe, as well as with the ISS astronaut crew. These tasks ranged from managing mission plan changes from around the globe, to uploading and downloading information to and from the ISS crew, to even more complex tasks that required multiple decision points to process the data, track approvals and deliver it to the correct recipient across network and security boundaries. The software solutions leveraged several different technologies including customized web applications and implementation of industry standard web services architecture between several planning tools; as well as a engaging a previously research level technology (TRL 2-3) developed by Ames Research Center (ARC) that utilized an intelligent agent based system to manage and automate file traffic flow

  8. Educational system, income inequality and growth: the median voter's decision

    Directory of Open Access Journals (Sweden)

    Joilson Dias

    2005-03-01

    Full Text Available I analyze a long run educational policy as a mechanism to close the income gap among low, median and high-income families. If the choice is made endogenous by the use of the median voter theorem, the results are as follow: i public education system guarantees income convergence, however the income growth rate of the median voter is smaller; ii the combination public and private (hybrid educational system allows faster income growth rate, but income inequality is almost the natural outcome. The ending result is that the combination public and private system will prevail, since the income growth rate of the median voter is higher in this system. This might explain the persistence and differences of income inequality among the economies.O objetivo deste artigo é analisar a utilização da política educacional no longo prazo como mecanismo para a redução da desigualdade de renda entre famílias de renda baixa, mediana e alta. Se a decisão sobre a política for endogeneizada, de acordo com o teorema do eleitor mediano, os resultados são os seguintes: i o sistema educacional público para todos, apesar de garantir convergência de renda, produz uma menor taxa de crescimento da renda do eleitor mediano; ii a combinação público-privado (sistema educacional híbrido permite uma maior taxa de crescimento da renda do eleitor mediano, no entanto a desigualdade de renda é inerente a este sistema. Como resultado final, o eleitor mediano irá escolher o sistema público-privado, pois o crescimento da sua renda é maior, o que pode explicar a persistência e as diferenças na desigualdade de renda das economias.

  9. Real-time risk assessment of operational events

    International Nuclear Information System (INIS)

    Perryman, L.J.; Foster, N.A.S.; Nicholls, D.R.; Grobbelaar, J.F.

    1996-01-01

    Probabilistic risk assessment (PRA) has always been fundamental to the licensing process of Koeberg nuclear power station. Furthermore, over the past 8 years PRA has assisted in many areas of operation. One of these areas is the real-time assessment of abnormal operating events. Over the years, considerable experience has been gained in using PRA to improve plant safety and performance. This paper presents some of the insights obtained in using PRA in such a dynamic role and demonstrates that, by developing and using the plant-specific 'living' PRA, considerable safety and financial gains can be obtained. These insights specifically concern the prerequisites before optimal use of a plant-specific 'living' PRA can be made. Finally, examples are presented of occurrences when PRA was used to improve plant safety and performance. These examples serve to demonstrate the advantages that can be obtained if sufficient resources are placed at the disposal of the PRA team. (orig.)

  10. Finite-element time evolution operator for the anharmonic oscillator

    Science.gov (United States)

    Milton, Kimball A.

    1995-01-01

    The finite-element approach to lattice field theory is both highly accurate (relative errors approximately 1/N(exp 2), where N is the number of lattice points) and exactly unitary (in the sense that canonical commutation relations are exactly preserved at the lattice sites). In this talk I construct matrix elements for dynamical variables and for the time evolution operator for the anharmonic oscillator, for which the continuum Hamiltonian is H = p(exp 2)/2 + lambda q(exp 4)/4. Construction of such matrix elements does not require solving the implicit equations of motion. Low order approximations turn out to be extremely accurate. For example, the matrix element of the time evolution operator in the harmonic oscillator ground state gives a results for the anharmonic oscillator ground state energy accurate to better than 1 percent, while a two-state approximation reduces the error to less than 0.1 percent.

  11. Synthesis of Biochemical Applications on Digital Microfluidic Biochips with Operation Execution Time Variability

    DEFF Research Database (Denmark)

    Alistar, Mirela; Pop, Paul

    2015-01-01

    that each biochemical operation in an application is characterized by a worst-case execution time (wcet). However, during the execution of the application, due to variability and randomness in biochemical reactions, operations may finish earlier than their wcetswcets, resulting in unexploited slack...... in the schedule. In this paper, we first propose an online synthesis strategy that re-synthesizes the application at runtime when operations experience variability in their execution time, exploiting thus the slack to obtain shorter application completion times. We also propose a quasi-static synthesis strategy...... approaches have been proposed for the synthesis of digital microfluidic biochips, which, starting from a biochemical application and a given biochip architecture, determine the allocation, resource binding, scheduling, placement and routing of the operations in the application. Researchers have assumed...

  12. Numerical Solution of Time-Dependent Problems with a Fractional-Power Elliptic Operator

    Science.gov (United States)

    Vabishchevich, P. N.

    2018-03-01

    A time-dependent problem in a bounded domain for a fractional diffusion equation is considered. The first-order evolution equation involves a fractional-power second-order elliptic operator with Robin boundary conditions. A finite-element spatial approximation with an additive approximation of the operator of the problem is used. The time approximation is based on a vector scheme. The transition to a new time level is ensured by solving a sequence of standard elliptic boundary value problems. Numerical results obtained for a two-dimensional model problem are presented.

  13. Time Management in the Operating Room: An Analysis of the Dedicated Minimally Invasive Surgery Suite

    Science.gov (United States)

    Hsiao, Kenneth C.; Machaidze, Zurab

    2004-01-01

    Background: Dedicated minimally invasive surgery suites are available that contain specialized equipment to facilitate endoscopic surgery. Laparoscopy performed in a general operating room is hampered by the multitude of additional equipment that must be transported into the room. The objective of this study was to compare the preparation times between procedures performed in traditional operating rooms versus dedicated minimally invasive surgery suites to see whether operating room efficiency is improved in the specialized room. Methods: The records of 50 patients who underwent laparoscopic procedures between September 2000 and April 2002 were retrospectively reviewed. Twenty-three patients underwent surgery in a general operating room and 18 patients in an minimally invasive surgery suite. Nine patients were excluded because of cystoscopic procedures undergone prior to laparoscopy. Various time points were recorded from which various time intervals were derived, such as preanesthesia time, anesthesia induction time, and total preparation time. A 2-tailed, unpaired Student t test was used for statistical analysis. Results: The mean preanesthesia time was significantly faster in the minimally invasive surgery suite (12.2 minutes) compared with that in the traditional operating room (17.8 minutes) (P=0.013). Mean anesthesia induction time in the minimally invasive surgery suite (47.5 minutes) was similar to time in the traditional operating room (45.7 minutes) (P=0.734). The average total preparation time for the minimally invasive surgery suite (59.6 minutes) was not significantly faster than that in the general operating room (63.5 minutes) (P=0.481). Conclusion: The amount of time that elapses between the patient entering the room and anesthesia induction is statically shorter in a dedicated minimally invasive surgery suite. Laparoscopic surgery is performed more efficiently in a dedicated minimally invasive surgery suite versus a traditional operating room. PMID

  14. Effects of smartphone overuse on hand function, pinch strength, and the median nerve.

    Science.gov (United States)

    İnal, Esra Erkol; Demİrcİ, kadİr; Çetİntürk, Azİze; Akgönül, Mehmet; Savaş, Serpİl

    2015-08-01

    In this study we investigated the flexor pollicis longus (FPL) tendon and median nerve in smartphone users by ultrasonography to assess the effects of smartphone addiction on the clinical and functional status of the hands. One hundred two students were divided into 3 groups: non-users, and high or low smartphone users. Smartphone Addiction Scale (SAS) scores and grip and pinch strengths were recorded. Pain in thumb movement and rest and hand function were evaluated on the visual analog scale (VAS) and the Duruöz Hand Index (DHI), respectively. The cross-sectional areas (CSAs) of the median nerve and the FPL tendon were calculated bilaterally using ultrasonography. Significantly higher median nerve CSAs were observed in the dominant hands of the high smartphone users than in the non-dominant hands (PSmartphone overuse enlarges the median nerve, causes pain in the thumb, and decreases pinch strength and hand functions. © 2015 Wiley Periodicals, Inc.

  15. Real-Time Science Operations to Support a Lunar Polar Volatiles Rover Mission

    Science.gov (United States)

    Heldmann, Jennifer L.; Colaprete, Anthony; Elphic, Richard C.; Mattes, Greg; Ennico, Kimberly; Fritzler, Erin; Marinova, Margarita M.; McMurray, Robert; Morse, Stephanie; Roush, Ted L.; hide

    2014-01-01

    Future human exploration of the Moon will likely rely on in situ resource utilization (ISRU) to enable long duration lunar missions. Prior to utilizing ISRU on the Moon, the natural resources (in this case lunar volatiles) must be identified and characterized, and ISRU demonstrated on the lunar surface. To enable future uses of ISRU, NASA and the CSA are developing a lunar rover payload that can (1) locate near subsurface volatiles, (2) excavate and analyze samples of the volatile-bearing regolith, and (3) demonstrate the form, extractability and usefulness of the materials. Such investigations are important both for ISRU purposes and for understanding the scientific nature of these intriguing lunar volatile deposits. Temperature models and orbital data suggest near surface volatile concentrations may exist at briefly lit lunar polar locations outside persistently shadowed regions. A lunar rover could be remotely operated at some of these locations for the approx. 2-14 days of expected sunlight at relatively low cost. Due to the limited operational time available, both science and rover operations decisions must be made in real time, requiring immediate situational awareness, data analysis, and decision support tools. Given these constraints, such a mission requires a new concept of operations. In this paper we outline the results and lessons learned from an analog field campaign in July 2012 which tested operations for a lunar polar rover concept. A rover was operated in the analog environment of Hawaii by an off-site Flight Control Center, a rover navigation center in Canada, a Science Backroom at NASA Ames Research Center in California, and support teams at NASA Johnson Space Center in Texas and NASA Kennedy Space Center in Florida. We find that this type of mission requires highly efficient, real time, remotely operated rover operations to enable low cost, scientifically relevant exploration of the distribution and nature of lunar polar volatiles. The field

  16. A study of retrograde degeneration of median nerve forearm ...

    African Journals Online (AJOL)

    Mona Mokhtar El Bardawil

    2013-10-22

    Oct 22, 2013 ... tient clinic of the Physical Medicine Rheumatology and Reha- bilitation ... F-wave to calculate axillary F central loop (AFCL) latency of median and ..... amplitude which substantially results from the block of faster ... Postoperative electrophysiological follow up for ... Regional rheumatic pain syndromes. In:.

  17. A novel image inpainting technique based on median diffusion

    Indian Academy of Sciences (India)

    numerical methods such as anisotropic diffusion and multiresolution schemes. Some steps ... Roth & Black (2005) have developed a framework for learning a generic and expressive image priors that ..... This paper presents a new approach for image inpainting by propagating median information .... J. Graphics Tools 9(1):.

  18. Investigation of survival time and disability characteristics in 5 subjects with bilateral thalamus infarction near median line%双侧中线旁丘脑梗死5例致残特点及生存期调查

    Institute of Scientific and Technical Information of China (English)

    翟明; 刘江; 钟静玫; 林岚

    2002-01-01

    @@ Background:Bilateral thalamus infarction near median line is uncommon in clinic.Reports concerned with this conditions were more less.It is characterized by conscious disorder and Korsakoff syndrome.The main caused may be the injury of intralaminar nuclei,dorsomedial nuclei,and injury of cortical matter,mammalillary bodies,fasciculus thalamicus around cerebral chamer III.Comprehensing the disability characteristics in pateints with bilateral thalamus infarction near median line is important for direction of rehabilitation.While study of survival time will improve evaluation of prognosis. Design:Patients recruited from June 1997~ October 2000 were analyzed. Unit:Intraneural Department of First People's Hospital of Yunnan Province. Subjects:55 subjects with MRI proved bilateral thalamus infarction near median line entered study.These patients included 3 women,2 men(age ranging from 50 to 77 years old,mean age:68.6 years).The period from onset to admission ranged from 5 hours to 2 days.All subejcts experienced acute bilateral thalamus infarction near median line.All had hypertension previously,1 had diabetes,2 had auricular fibrillation. Intervention:All patients received management which was conducted according to protocol for treatment of ischemic cerebrovascular diseases. Patients clinical characteristics were summari-zed and analyzed.Follow up was conducted to determine the survival period. Main evaluation indexes:Survival time and conscious disorder were evaluated. Result:All patients showed different level of conscious disorder.3 cases developed thalamic dementia,2 developed vision numb,In 1 case,condition progressively deteriorated manifesting as moderate coma progressed to deep coma,and bilateral mydriasis.Finally,this patients died of central respiratory and circulatory failure after 8 days.4 cases with favorable prognosis discharged,3 out of them died within 1 year after discharge.Survival subject suffered from reduced memory was followed up till now

  19. Controlled time of arrival windows for already initiated energy-neutral continuous descent operations

    OpenAIRE

    Dalmau Codina, Ramon; Prats Menéndez, Xavier

    2017-01-01

    Continuous descent operations with controlled times of arrival at one or several metering fixes could enable environmentally friendly procedures without compromising terminal airspace capacity. This paper focuses on controlled time of arrival updates once the descent has been already initiated, assessing the feasible time window (and associated fuel consumption) of continuous descent operations requiring neither thrust nor speed-brake usage along the whole descent (i.e. only elevator control ...

  20. Army Secure Operating System: Information Security for Real Time Systems

    National Research Council Canada - National Science Library

    Anderson, Eric

    1984-01-01

    The Army Secure Operating System (ASOS) project, under the management of the U.S. Army CECOM organization, will provide real time systems software necessary for fielding modern Battlefield Automation Systems...

  1. Expert system of real time for support of operators of atomic power plants

    International Nuclear Information System (INIS)

    Bashlykov, A.A.; Davidenko, N.N.; Dumshev, V.G.; Kislov, G.I.; Pavlova, E.V.; Prozorovskij, E.D.; Bashlykov, A.A.

    1994-01-01

    The problems of construction and introdution of an intellectual system for information support of operators at nuclear power plants are discussed. This system is used for operator assisstance during real time decision making for NPP operational regime control

  2. Fuzzy operation and real time surveillance of a nuclear reactor

    International Nuclear Information System (INIS)

    Si-Fodil, M.; Guely, F.; Siarry, P.; Tyran, J.L.

    1997-01-01

    The operating power of nuclear power plants needs to be modulated according to the thin evolutions of electric power demand. Two parameters are concerned by load following operations: the power axial disequilibrium and the position of control rods. This paper deals with the automation of the control of power axial disequilibrium using boration-dilution. An automatic system based on fuzzy logic is proposed which can be substituted to the expert operator who is in charge of this fastidious manual task. The management of water and boron flow rates are studied in details. A Graphic interface was designed for the real-time surveillance of the reactor. (J.S.)

  3. CT morphology of benign median nerve tumors

    International Nuclear Information System (INIS)

    Feyerabend, T.; Schmitt, R.; Lanz, U.; Warmuth-Metz, M.; Wuerzburg Univ.

    1990-01-01

    Computed tomography (CT) was performed in 3 patients with benign tumors of the median nerve, histologically confirmed as neurilemmoma, fibrolipoma and hemangioma. The neurilemmoma showed a ring-shaped contrast enhancement. The fibrolipoma presented with areas of solid soft tissue and areas of fat. The hemangioma was a solid tumor with a lacunar, vascular contrast enhancement. According to our experience and to the previous literature CT gives useful information regarding the anatomic location, size, and relationship of peripheral nerve sheath tumors to surrounding structures, and may help to differentiate between various tumor types. (orig.)

  4. Real-Time Assessment and Diagnosis of Process Operating Performance

    Directory of Open Access Journals (Sweden)

    Shabnam Sedghi

    2017-04-01

    Full Text Available Over time, the performance of processes may deviate from the initial design due to process variations and uncertainties, making it necessary to develop systematic methods for online optimality assessment based on routine operating process data. Some processes have multiple operating modes caused by the set point change of the critical process variables to achieve different product specifications. On the other hand, the operating region in each operating mode can alter, due to uncertainties. In this paper, we will establish an optimality assessment framework for processes that typically have multi-mode, multi-region operations, as well as transitions between different modes. The kernel density approach for mode detection is adopted and improved for operating mode detection. For online mode detection, the model-based clustering discriminant analysis (MclustDA approach is incorporated with some a priori knowledge of the system. In addition, multi-modal behavior of steady-state modes is tackled utilizing the mixture probabilistic principal component regression (MPPCR method, and dynamic principal component regression (DPCR is used to investigate transitions between different modes. Moreover, a probabilistic causality detection method based on the sequential forward floating search (SFFS method is introduced for diagnosing poor or non-optimum behavior. Finally, the proposed method is tested on the Tennessee Eastman (TE benchmark simulation process in order to evaluate its performance.

  5. Use of the temporal median and trimmed mean mitigates effects of respiratory motion in multiple-acquisition abdominal diffusion imaging

    International Nuclear Information System (INIS)

    Jerome, N P; Orton, M R; D’Arcy, J A; Leach, M O; Collins, D J; Feiweier, T; Tunariu, N; Koh, D-M

    2015-01-01

    Respiratory motion commonly confounds abdominal diffusion-weighted magnetic resonance imaging, where averaging of successive samples at different parts of the respiratory cycle, performed in the scanner, manifests the motion as blurring of tissue boundaries and structural features and can introduce bias into calculated diffusion metrics. Storing multiple averages separately allows processing using metrics other than the mean; in this prospective volunteer study, median and trimmed mean values of signal intensity for each voxel over repeated averages and diffusion-weighting directions are shown to give images with sharper tissue boundaries and structural features for moving tissues, while not compromising non-moving structures. Expert visual scoring of derived diffusion maps is significantly higher for the median than for the mean, with modest improvement from the trimmed mean. Diffusion metrics derived from mono- and bi-exponential diffusion models are comparable for non-moving structures, demonstrating a lack of introduced bias from using the median. The use of the median is a simple and computationally inexpensive alternative to complex and expensive registration algorithms, requiring only additional data storage (and no additional scanning time) while returning visually superior images that will facilitate the appropriate placement of regions-of-interest when analysing abdominal diffusion-weighted magnetic resonance images, for assessment of disease characteristics and treatment response. (note)

  6. Retroperitoneal laparoscopic nephrectomy: the effect of the learning curve, and concentrating expertise, on operating times.

    Science.gov (United States)

    Skinner, Adrian; Maoate, Kiki; Beasley, Spencer

    2010-05-01

    Laparoscopic nephrectomy is an accepted alternative to open nephrectomy. We analyzed our first 80 procedures of laparoscopic nephrectomy to evaluate the effect of experience and configuration of service on operative times. A retrospective review of 80 consecutive children who underwent retroperitoneal laparoscopic nephrectomy or heminephrectomy during an 11-year period from 1997 at Christchurch Hospital (Christchurch, New Zealand) was conducted. Operative times, in relation to the experience of the surgeon for this procedure, were analyzed. Four surgeons, assisted by an annually rotating trainee registrar, performed the procedure in 26 girls and 54 boys (range, 8 months to 15 years). Operating times ranged from 38 to 225 minutes (mean, 104). The average operative time fell from 105 to 90 minutes. One surgeon performed 40% of the procedures and assisted with a further 55%. The operative times for all surgeons showed a tendency to reduce, but this was not marked. Most procedures were performed by two surgeons working together, although one surgeon was involved in the majority of cases. The lead surgeon is often assisted by a fellow consultant colleague. Operative times were influenced by experience, but not markedly so. The shorter operative times and minimal "learning curve," compared with other reported series, may, in part, be due to the involvement of two surgeons experienced in laparoscopy for the majority of cases.

  7. Median nerve cross-sectional area and MRI diffusion characteristics: normative values at the carpal tunnel

    International Nuclear Information System (INIS)

    Yao, Lawrence; Gai, Neville

    2009-01-01

    Enlargement of the median nerve is an objective potential imaging sign of carpal tunnel syndrome. Diffusion tensor MRI (DTI) may provide additional structural information that may prove useful in characterizing median neuropathy. This study further examines normal values for median nerve cross-sectional area (CSA), apparent diffusion coefficient (ADC), and fractional anisotropy (FA). Twenty-three wrists in 17 healthy volunteers underwent MRI of the wrist at 3 T. In 13 subjects, DTI was performed at a B value of 600 mm 2 /s. Median nerve CSA, ADC, and FA were analyzed at standardized anatomic levels. Mean (SD) median nerve CSA within the proximal carpal tunnel was 10.0 (3.4) mm 2 . The mean (SD) FA of the median nerve was 0.71 (0.06) and 0.70 (0.13) proximal to and within the carpal tunnel, respectively. There was a significant difference between nerve CSA and ADC, but not FA, at the distal forearm and proximal carpal tunnel. Nerve CSA, ADC, and FA did not differ between men and women or between dominant and non-dominant wrists. Nerve CSA at the proximal carpal tunnel was positively correlated with subject age and body mass index. Our results suggest a 90% upper confidence limit for normal median nerve CSA of 14.4 mm 2 at the proximal carpal tunnel, higher than normal limits reported by many ultrasound studies. We observed a difference between the CSA and ADC, but not the FA, of the median nerve at the distal forearm and proximal carpal tunnel levels. (orig.)

  8. Integrated real-time information to use in commercial, logistics and operational activities provide by the national control center operation of Transpetro

    Energy Technology Data Exchange (ETDEWEB)

    Aniceto, Hello A. R. [National Control Center Operation Transpetro, Rio de Janeiro, (Brazil)

    2010-07-01

    TRANSPETRO needed real time computational tools to manage its commercial, logistics and operational activities more efficiently. TRANSPETRO's National Control Center Operation developed an information site that provides information in real time on the process plans involved in each operation, using a Plant Information Management System (PIMS). SCADA systems were introduced during 2009 and 2010. This paper reports on the global introduction of the site and its basic architecture. Every screen displays the overall data in real time on movement in volume in pipeline operated by TRANSPETRO. The products transported are tracked for each infrastructure and are shown on dynamic geographic maps. Applications have been developed to improve the quality of information available to customers. It was found that the development of this site using PIMS technology brought gains in support to decision-making at the strategic and tactical levels for TRANSPETRO.

  9. Effectiveness Analysis of a Part-Time Rapid Response System During Operation Versus Nonoperation.

    Science.gov (United States)

    Kim, Youlim; Lee, Dong Seon; Min, Hyunju; Choi, Yun Young; Lee, Eun Young; Song, Inae; Park, Jong Sun; Cho, Young-Jae; Jo, You Hwan; Yoon, Ho Il; Lee, Jae Ho; Lee, Choon-Taek; Do, Sang Hwan; Lee, Yeon Joo

    2017-06-01

    To evaluate the effect of a part-time rapid response system on the occurrence rate of cardiopulmonary arrest by comparing the times of rapid response system operation versus nonoperation. Retrospective cohort study. A 1,360-bed tertiary care hospital. Adult patients admitted to the general ward were screened. Data were collected over 36 months from rapid response system implementation (October 2012 to September 2015) and more than 45 months before rapid response system implementation (January 2009 to September 2012). None. The rapid response system operates from 7 AM to 10 PM on weekdays and from 7 AM to 12 PM on Saturdays. Primary outcomes were the difference of cardiopulmonary arrest incidence between pre-rapid response system and post-rapid response system periods and whether the rapid response system operating time affects the cardiopulmonary arrest incidence. The overall cardiopulmonary arrest incidence (per 1,000 admissions) was 1.43. Although the number of admissions per month and case-mix index were increased (3,555.18 vs 4,564.72, p times (0.82 vs 0.49/1,000 admissions; p = 0.001) but remained similar during rapid response system nonoperating times (0.77 vs 0.73/1,000 admissions; p = 0.729). The implementation of a part-time rapid response system reduced the cardiopulmonary arrest incidence based on the reduction of cardiopulmonary arrest during rapid response system operating times. Further analysis of the cost effectiveness of part-time rapid response system is needed.

  10. A computer-based time study system for timber harvesting operations

    Science.gov (United States)

    Jingxin Wang; Joe McNeel; John Baumgras

    2003-01-01

    A computer-based time study system was developed for timber harvesting operations. Object-oriented techniques were used to model and design the system. The front-end of the time study system resides on the MS Windows CE and the back-end is supported by MS Access. The system consists of three major components: a handheld system, data transfer interface, and data storage...

  11. A study of retrograde degeneration of median nerve forearm ...

    African Journals Online (AJOL)

    Introduction: Carpal tunnel syndrome (CTS) is a disorder of the hand which results from compression of the median nerve within its fibro-osseous tunnel at the wrist. The slowing in the forearm motor conduction velocity suggests the presence of retrograde degeneration. Existing studies conflict regarding a correlation ...

  12. l-Arginine Pathway Metabolites Predict Need for Intra-operative Shunt During Carotid Endarterectomy

    DEFF Research Database (Denmark)

    Szabo, P; Lantos, J; Nagy, L

    2016-01-01

    lactate levels were increased during reperfusion (p = .02). The median pre-operative concentration of l-arginine was lower in patients requiring an intra-operative shunt than in patients without need of shunt (median: 30.3 μmol/L [interquartile range 24.4-34.4 μmol/L] vs. 57.6 μmol/L [interquartile range...

  13. A Systematic Approach for Real-Time Operator Functional State Assessment

    Science.gov (United States)

    Zhang, Guangfan; Wang, Wei; Pepe, Aaron; Xu, Roger; Schnell, Thomas; Anderson, Nick; Heitkamp, Dean; Li, Jiang; Li, Feng; McKenzie, Frederick

    2012-01-01

    A task overload condition often leads to high stress for an operator, causing performance degradation and possibly disastrous consequences. Just as dangerous, with automated flight systems, an operator may experience a task underload condition (during the en-route flight phase, for example), becoming easily bored and finding it difficult to maintain sustained attention. When an unexpected event occurs, either internal or external to the automated system, the disengaged operator may neglect, misunderstand, or respond slowly/inappropriately to the situation. In this paper, we discuss an approach for Operator Functional State (OFS) monitoring in a typical aviation environment. A systematic ground truth finding procedure has been designed based on subjective evaluations, performance measures, and strong physiological indicators. The derived OFS ground truth is continuous in time compared to a very sparse estimation of OFS based on an expert review or subjective evaluations. It can capture the variations of OFS during a mission to better guide through the training process of the OFS assessment model. Furthermore, an OFS assessment model framework based on advanced machine learning techniques was designed and the systematic approach was then verified and validated with experimental data collected in a high fidelity Boeing 737 simulator. Preliminary results show highly accurate engagement/disengagement detection making it suitable for real-time applications to assess pilot engagement.

  14. Effects of operator time pressure and noise on manual ultrasonic testing

    International Nuclear Information System (INIS)

    Enkvist, J.; Edland, A.; Svenson, O.

    2002-01-01

    In earlier studies of manual ultrasonic testing, great variations have been found in operator performance, often attributed to operator fatigue. However, no conclusive findings have been reported. In the present study, twenty operators performed manual ultrasonic inspections of six test-pieces with manufactured flaws. The operators performed the inspections under stress (high arousal - time pressure and noise) and no-stress conditions; one condition the first day and the other the second and last day. According to the Yerkes-Dodson Law there is an optimal arousal level where performance is highest. It was hypothesised that the stress condition led to a level of arousal so high that it would affect the results negatively. However, contrary to the hypotheses it was found that the manipulation increased operator performance. Operators with the stress condition day 1 performed better than the other operators (under the no-stress condition). This was interpreted as the 'stress first' (group 1) operators had established efficient performance patterns the first day - affecting also the second day. Operators beginning with stress condition also tended to be more motivated. It was concluded that operator performance is affected by arousal. (author)

  15. Time-dependent reliability analysis of nuclear reactor operators using probabilistic network models

    International Nuclear Information System (INIS)

    Oka, Y.; Miyata, K.; Kodaira, H.; Murakami, S.; Kondo, S.; Togo, Y.

    1987-01-01

    Human factors are very important for the reliability of a nuclear power plant. Human behavior has essentially a time-dependent nature. The details of thinking and decision making processes are important for detailed analysis of human reliability. They have, however, not been well considered by the conventional methods of human reliability analysis. The present paper describes the models for the time-dependent and detailed human reliability analysis. Recovery by an operator is taken into account and two-operators models are also presented

  16. Variability of pudendal and median nerve sensory perception thresholds in healthy persons.

    Science.gov (United States)

    Quaghebeur, Jörgen; Wyndaele, Jean-Jacques

    2015-04-01

    Normative current perception thresholds (CPTs) are used for the evaluation of sensory function in a variety of diseases. To evaluate the reproducibility of CPT measurements with sinusoidal current in healthy volunteers. Neuroselective CPT evaluations of the median and pudendal nerve in healthy volunteers were repeated with 1 week interval (T1 and T2). In the study group (N = 41) no difference between genders for age (MW-U: P = 0.91) and BMI (t-test: P = 0.18) were found. No significant difference between T1 and T2 was found (Paired t-test: all P-values > 0.05), although the intraclass correlation for each person was low. The variability of measures for the pudendal nerve was: ICC 2 kHz: 0.41; 250 Hz: 0.30; 5 Hz: 0.38, and for the median nerve respectively: 0.58; 0.46; 0.40. Normal CPTs were shown for the pudendal nerve: 2 kHz: 51%; 250 Hz: 76%; 5 Hz: 71%, and median nerve respectively: 78%; 98%; 80%. The pudendal nerve showed more deviating values compared to the median nerve. Both nerves showed deviating values. CPT values with sinusoidal current assessed with 1 week interval, showed a weak intraclass correlation. This finding limits the use of CPT values with this current for longitudinal studies. © 2014 Wiley Periodicals, Inc.

  17. Accelerated magnetic resonance diffusion tensor imaging of the median nerve using simultaneous multi-slice echo planar imaging with blipped CAIPIRINHA.

    Science.gov (United States)

    Filli, Lukas; Piccirelli, Marco; Kenkel, David; Boss, Andreas; Manoliu, Andrei; Andreisek, Gustav; Bhat, Himanshu; Runge, Val M; Guggenberger, Roman

    2016-06-01

    To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA. After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm(2); 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test. Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm(2)/s; twofold acceleration: 1.016 ± 0.123 mm(2)/s; threefold acceleration: 0.979 ± 0.153 mm(2)/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021). Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI. • Standard DTI of the median nerve is limited by its long acquisition time. • Simultaneous multi-slice acquisition is a new technique for accelerated DTI. • Accelerated DTI of the median nerve yields similar results to standard DTI.

  18. Realization of a unique time evolution unitary operator in Klein Gordon theory

    International Nuclear Information System (INIS)

    Balasubramanian, T.S.; Bhatia, S.Kr.

    1986-01-01

    The scattering theory for the Klein Gordon equation, with time-dependent potential and in a non-static space-time, is considered. Using the Klein Gordon equation formulated in the Hilbert space L 2 (R 3 ) and the Einstein's relativistic equation in the space L 2 (R 3 ,dx) and establishing the equivalence of the vacuum states of their linearized forms in the Hilbert space L 2 (R 3 ) with the help of unique symmetric symplectic operator, the time evolution unitary operator U(t) has been fixed for the Klein Gordon eqution, incorporating either the positive or negative frequencies, in the infinite dimensional Hilbert space L 2 (R 3 ). (author)

  19. Reconstruction of a 10-mm-long median nerve gap in an ischemic environment using autologous conduits with different patterns of blood supply: A comparative study in the rat

    Science.gov (United States)

    Iria, Inês; Alves, Sara; Farinho, Ana; Pen, Cláudia; Lourenço-Silva, Nuno; Mascarenhas-Lemos, Luís; Silva-Ferreira, José; Ferraz-Oliveira, Mário; Vassilenko, Valentina; Videira, Paula Alexandra; Goyri-O’Neill, João; Pais, Diogo

    2018-01-01

    The aim of this study was to evaluate in the Wistar rat the efficacy of various autologous nerve conduits with various forms of blood supply in reconstructing a 10-mm-long gap in the median nerve (MN) under conditions of local ischemia. A 10-mm-long median nerve defect was created in the right arm. A loose silicone tube was placed around the nerve gap zone, in order to simulate a local ischemic environment. Rats were divided in the following experimental groups (each with 20 rats): the nerve Graft (NG) group, in which the excised MN segment was reattached; the conventional nerve flap (CNF) and the arterialized neurovenous flap (ANVF) groups in which the gap was bridged with homonymous median nerve flaps; the prefabricated nerve flap (PNF) group in which the gap was reconstructed with a fabricated flap created by leaving an arteriovenous fistula in contact with the sciatic nerve for 5 weeks; and the two control groups, Sham and Excision groups. In the latter group, the proximal stump of the MN nerve was ligated and no repair was performed. The rats were followed for 100 days. During this time, they did physiotherapy. Functional, electroneuromyographic and histological studies were performed. The CNF and ANVF groups presented better results than the NG group in the following assessments: grasping test, nociception, motor stimulation threshold, muscle weight, and histomorphometric evaluation. Radial deviation of the operated forepaw was more common in rats that presented worse results in the other outcome variables. Overall, CNFs and ANVFs produced a faster and more complete recovery than NGs in the reconstruction of a 10-mm-long median nerve gap in an ischemic environment in the Wistar rat. Although, results obtained with CNFs were in most cases were better than ANVFs, these differences were not statistically significant for most of the outcome variables. PMID:29659600

  20. Factors impacting arthroscopic rotator cuff repair operational throughput time at an ambulatory care center

    Directory of Open Access Journals (Sweden)

    Emily J. Curry

    2018-03-01

    Full Text Available Identifying patient factors influencing operational throughput time is becoming more imperative due to an increasing focus on value and cost savings in healthcare. The primary objective of this study was to determine patient factors influencing throughput time for primary rotator cuff repairs. Demographic information, medical history and operative reports of 318 patients from one ambulatory care center were retrospectively reviewed. Operating room set up, incision to closure and recovery room time were collected from anesthesia records. Univariate analysis was performed for both continuous and categorical variables. A stepwise, multivariable regression analysis was performed to determine factors associated with operating room time (incision to closure and recovery room time. Of the 318 patients, the mean age was 54.4±10.0 and 197 (61% were male. Male patients had a significantly longer OR time than females (115.5 vs. 100.8 minutes; P<0.001. Furthermore, patients set up in the beach chair position had a significantly longer OR time than patients positioned lateral decubitus (115.8 vs. 89.6 mins, P<0.0001. Number of tendons involved, and inclusion of distal clavicle excision, biceps tenodesis and labral debridement also added significant OR time. Type and number of support staff present also significantly affected OR time. Recovery room time was significantly longer patients who had surgery in the beach chair position (+9.61 minutes and for those who had a cardiac-related medical comorbidity (+11.7 minutes. Our study found that patients positioned in a beach chair spent significantly more time in the operating and recovery rooms. While ease of set up has been a stated advantage ofbeach chair position, we found the perceived ease of set up does not result in more efficient OR throughput.

  1. 16 CFR Figure 2 to Part 1203 - ISO Headform-Basic, Reference, and Median Planes

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false ISO Headform-Basic, Reference, and Median Planes 2 Figure 2 to Part 1203 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT... Headform-Basic, Reference, and Median Planes ER10MR98.002 ...

  2. Real-time observations of stressful events in the operating room

    Directory of Open Access Journals (Sweden)

    AlNassar Sami

    2012-01-01

    Full Text Available Aim: To identify and quantify factors causing stress in the operating room (OR and evaluate the relationship between these factors and surgeons′ stress level. Methods: This is a prospective observational study from 32 elective surgical procedures conducted in the OR of King Khalid University Hospital, Riyadh, Saudi Arabia. Before each operation, each surgeon was asked of stressors. Two interns observed 16 surgeries each, separately. The interns watched and took notes during the entire surgical procedure. During each operation, the observer recorded anxiety-inducing activities and events that occurred in real time by means of a checklist of 8 potential stressors: technical, patient problems, teamwork problems, time and management issues, distractions and interruptions, equipment problems, personal problems, and teaching. After each operation, surgeons were asked to answer the validated State-Trait Anxiety Inventory questionnaire and self-report on their stress level from the 8 sources using a scale of 1-8 (1: stress free, 8: extremely stressful. The observer also recorded perceived stress levels experienced by the surgeons during the operation. Results: One hundred ten stressors were identified. Technical problems most frequently caused stress (16.4% and personal issues the least often (6.4%. Frequently encountered stressors (teaching and distractions/interruptions caused less stress to the surgeons. Technical factors, teamwork, and equipment problems occurred frequently and were also a major contributor to OR stress. All patients were discharged in good health and within 1 week of surgery. Conclusion: Certain stressful factors do occur among surgeons in the OR and can increase the potential for errors. Further research is required to determine the impact of stress on performance and the outcome of surgery.

  3. Decision of Lead-Time Compression and Stable Operation of Supply Chain

    Directory of Open Access Journals (Sweden)

    Songtao Zhang

    2017-01-01

    Full Text Available A cost optimization strategy and a robust control strategy were studied to realize the low-cost robust operation of the supply chain with lead times. Firstly, for the multiple production lead times which existed in the supply chain, a corresponding inventory state model and a supply chain cost model were constructed based on the Takagi-Sugeno fuzzy control system. Then, by considering the actual inventory level, the lead-time compression cost, and the stock-out cost, a cost optimization strategy was proposed. Furthermore, a fuzzy robust control strategy was proposed to realize the flexible switching among the models. Finally, the simulation results show that the total cost of the supply chain could be reduced effectively by the cost optimization strategy, and the stable operation of the supply chain could be realized by the proposed fuzzy robust control strategy.

  4. A Rare Variation of the Human Median Nerve Direction

    Directory of Open Access Journals (Sweden)

    Barfi

    2016-04-01

    Full Text Available Introduction The brachial plexus, a complex network of nerves, innervates to the upper limbs. Variation in the course of the nerves in the upper limb is common. Case Presentation This paper describes two cases of upper limb variations in a cadaver dissected at Lorestan University of Medical Sciences. In the first variation, the median nerve in the arm has a different route, so that the median moves deep into the brachialis muscle. In the latter case, after piercing the coracobrachialis muscle a musculocutaneous nerve exists between the brachialis and biceps and goes to the lateral region of the forearm. This is known as the lateral cutaneous nerve of the forearm nerve, and innervates the skin of the lateral part of the forearm and the dorsal part of the hand. Conclusions Because of the possibility of damage to the brachial plexus branches is high in upper limb injuries and surgeries, full knowledge of normal anatomy and variations of these branches is essential for orthopedic specialists, neurosurgeons, radiologists, and anatomists.

  5. Kajian dan Implementasi Real TIME Operating System pada Single Board Computer Berbasis Arm

    OpenAIRE

    A, Wiedjaja; M, Handi; L, Jonathan; Christian, Benyamin; Kristofel, Luis

    2014-01-01

    Operating System is an important software in computer system. For personal and office use the operating system is sufficient. However, to critical mission applications such as nuclear power plants and braking system on the car (auto braking system) which need a high level of reliability, it requires operating system which operates in real time. The study aims to assess the implementation of the Linux-based operating system on a Single Board Computer (SBC) ARM-based, namely Pandaboard ES with ...

  6. Research on Control Method Based on Real-Time Operational Reliability Evaluation for Space Manipulator

    Directory of Open Access Journals (Sweden)

    Yifan Wang

    2014-05-01

    Full Text Available A control method based on real-time operational reliability evaluation for space manipulator is presented for improving the success rate of a manipulator during the execution of a task. In this paper, a method for quantitative analysis of operational reliability is given when manipulator is executing a specified task; then a control model which could control the quantitative operational reliability is built. First, the control process is described by using a state space equation. Second, process parameters are estimated in real time using Bayesian method. Third, the expression of the system's real-time operational reliability is deduced based on the state space equation and process parameters which are estimated using Bayesian method. Finally, a control variable regulation strategy which considers the cost of control is given based on the Theory of Statistical Process Control. It is shown via simulations that this method effectively improves the operational reliability of space manipulator control system.

  7. Development of a processor embedded timing unit for the synchronized operation in KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woongryol, E-mail: wrlee@nfri.re.kr; Lee, Taegu; Hong, Jaesic

    2016-11-15

    Highlights: • Timing board for the synchronized tokamak operation. • Processor embedded distributed control system. • Single clock source and multiple trigger signal for the plasma diagnostics. • Delay compensation among the distributed timing boards. - Abstract: The Local Timing Unit (LTU) in KSTAR provides a single clock source and multiple trigger signals with flexible configuration. Over the past seven years, the LTU had a mechanical redesign and several firmware updates for the purpose of provision of a robust operation and precision timing signal. Now we have developed a third version of a local timing unit which has a standalone operation capability. The LTU is built in a cabinet mountable 1U PIZZA box and provides twelve signal output ports, a packet mirroring interface, and an LCD interface panel. The core functions of the LTU are implemented in a Field Programmable Gate Array (FPGA) which has an internal hardcore processor. The internal processor allows the use of Linux Operating System (OS) and the Experimental Physics and Industrial Control System (EPICS). All user level application functions are controllable through the EPICS, however the time critical internal functions are performed by the FPGA logic blocks same as the previous version. The new LTU provides pluggable output module so that we can easily extend the signal output port. The easy installation and effective replacement reduce the efforts of maintenance. This paper describes design, development, and commissioning results of the new KSTAR LTU.

  8. Development of a processor embedded timing unit for the synchronized operation in KSTAR

    International Nuclear Information System (INIS)

    Lee, Woongryol; Lee, Taegu; Hong, Jaesic

    2016-01-01

    Highlights: • Timing board for the synchronized tokamak operation. • Processor embedded distributed control system. • Single clock source and multiple trigger signal for the plasma diagnostics. • Delay compensation among the distributed timing boards. - Abstract: The Local Timing Unit (LTU) in KSTAR provides a single clock source and multiple trigger signals with flexible configuration. Over the past seven years, the LTU had a mechanical redesign and several firmware updates for the purpose of provision of a robust operation and precision timing signal. Now we have developed a third version of a local timing unit which has a standalone operation capability. The LTU is built in a cabinet mountable 1U PIZZA box and provides twelve signal output ports, a packet mirroring interface, and an LCD interface panel. The core functions of the LTU are implemented in a Field Programmable Gate Array (FPGA) which has an internal hardcore processor. The internal processor allows the use of Linux Operating System (OS) and the Experimental Physics and Industrial Control System (EPICS). All user level application functions are controllable through the EPICS, however the time critical internal functions are performed by the FPGA logic blocks same as the previous version. The new LTU provides pluggable output module so that we can easily extend the signal output port. The easy installation and effective replacement reduce the efforts of maintenance. This paper describes design, development, and commissioning results of the new KSTAR LTU.

  9. A real-time control framework for urban water reservoirs operation

    Science.gov (United States)

    Galelli, S.; Goedbloed, A.; Schwanenberg, D.

    2012-04-01

    Drinking water demand in urban areas is growing parallel to the worldwide urban population, and it is acquiring an increasing part of the total water consumption. Since the delivery of sufficient water volumes in urban areas represents a difficult logistic and economical problem, different metropolitan areas are evaluating the opportunity of constructing relatively small reservoirs within urban areas. Singapore, for example, is developing the so-called 'Four National Taps Strategies', which detects the maximization of water yields from local, urban catchments as one of the most important water sources. However, the peculiar location of these reservoirs can provide a certain advantage from the logistical point of view, but it can pose serious difficulties in their daily management. Urban catchments are indeed characterized by large impervious areas: this results in a change of the hydrological cycle, with decreased infiltration and groundwater recharge, and increased patterns of surface and river discharges, with higher peak flows, volumes and concentration time. Moreover, the high concentrations of nutrients and sediments characterizing urban discharges can cause further water quality problems. In this critical hydrological context, the effective operation of urban water reservoirs must rely on real-time control techniques, which can exploit hydro-meteorological information available in real-time from hydrological and nowcasting models. This work proposes a novel framework for the real-time control of combined water quality and quantity objectives in urban reservoirs. The core of this framework is a non-linear Model Predictive Control (MPC) scheme, which employs the current state of the system, the future discharges furnished by a predictive model and a further model describing the internal dynamics of the controlled sub-system to determine an optimal control sequence over a finite prediction horizon. The main advantage of this scheme stands in its reduced

  10. Real time evolution at finite temperatures with operator space matrix product states

    International Nuclear Information System (INIS)

    Pižorn, Iztok; Troyer, Matthias; Eisler, Viktor; Andergassen, Sabine

    2014-01-01

    We propose a method to simulate the real time evolution of one-dimensional quantum many-body systems at finite temperature by expressing both the density matrices and the observables as matrix product states. This allows the calculation of expectation values and correlation functions as scalar products in operator space. The simulations of density matrices in inverse temperature and the local operators in the Heisenberg picture are independent and result in a grid of expectation values for all intermediate temperatures and times. Simulations can be performed using real arithmetics with only polynomial growth of computational resources in inverse temperature and time for integrable systems. The method is illustrated for the XXZ model and the single impurity Anderson model. (paper)

  11. Real time evolution at finite temperatures with operator space matrix product states

    Science.gov (United States)

    Pižorn, Iztok; Eisler, Viktor; Andergassen, Sabine; Troyer, Matthias

    2014-07-01

    We propose a method to simulate the real time evolution of one-dimensional quantum many-body systems at finite temperature by expressing both the density matrices and the observables as matrix product states. This allows the calculation of expectation values and correlation functions as scalar products in operator space. The simulations of density matrices in inverse temperature and the local operators in the Heisenberg picture are independent and result in a grid of expectation values for all intermediate temperatures and times. Simulations can be performed using real arithmetics with only polynomial growth of computational resources in inverse temperature and time for integrable systems. The method is illustrated for the XXZ model and the single impurity Anderson model.

  12. Pudendal and median nerve sensory perception threshold: a comparison between normative studies.

    Science.gov (United States)

    Quaghebeur, Jörgen; Wyndaele, Jean Jacques

    2014-12-01

    For the evaluation of sensory innervation, normative data are necessary as a comparison. To compare our current perception thresholds (CPTs) with normative data from other research. Healthy volunteers were assessed for 2000, 250, and 5 Hz CPTs of the median and pudendal nerve and data were compared with other studies. Normative data in the studied group n = 41 (male: 21; female: 20) for the median nerve, 2 kHz, 250 Hz, and 5 Hz were respectively: 241.85 ± 67.72 (140-444); 106.27 ± 39.12 (45-229); 82.05 ± 43.40 (13-271). Pudendal nerve CPTs 250 Hz were: 126.44 ± 69.46 (6-333). For men 2 kHz: 349.95 ± 125.76 (100-588); 5 Hz: 132.67 ± 51.81 (59-249) and women 2 kHz:226.20 ± 119.65 (64-528); 5 Hz: 92.45 ± 44.66 (35-215). For the median nerve no statistical differences for gender were shown. For the pudendal nerve, only 250 Hz showed no difference for gender (t-test: 0.516). Comparison of our data with CPTs of other normative data showed no agreement for the pudendal nerve. For the median nerve only 2 kHz showed agreement in three studies and for 5 Hz with one study. Comparing normative data of multiple studies shows a variety of results and poor agreement. Therefore, referring to normative data of other studies should be handled with caution.

  13. Post-operative treatment of malignant salivary gland tumours of the palate with iodine-125 brachytherapy

    International Nuclear Information System (INIS)

    Stannard, Clare E.; Hering, Egbert; Hough, Jan; Knowles, Ruth; Munro, Roger; Hille, Jos

    2004-01-01

    Background and purpose: Malignant minor salivary gland tumours are usually small and clinically indistinguishable from benign lesions. Surgery is the treatment of choice with post-operative radiotherapy for involved margins or unfavourable histology. We assessed the results of a series of such patients treated with iodine-125 brachytherapy in the form of a temporary applicator or implant. Patients and methods: There were nine patients with T1/T2 tumours of the hard and/or soft palate that had been excised. All had close or involved margins. Six were treated with a dental applicator alone, two with an applicator and additional I-125 seeds in tubes and one with an implant alone. The applicator consists of two layers of plastic made from a dental impression enclosing a predetermined number of I-125 seeds, 9-39, glued to one surface and a layer of ash metal to protect the tongue. It was inserted 1-3 months post-operatively and delivered 35-62 Gy, median 56 Gy, at 5-7 mm depth over 58-156 h, median 120 h, at 0.26-0.67 Gy/h, median 0.45 Gy/h. Results: The patients have been followed up for 32-158 months, median 50 months, and there were no recurrences. The applicator was well tolerated. A confluent mucositis developed which lasted 3-4 weeks. One patient developed a mucosal ulcer which healed spontaneously. Conclusions: Brachytherapy is an effective way of delivering post-operative radiotherapy to the hard and soft palate in patients with malignant salivary gland tumours that have been incompletely excised or have unfavourable histology. Local control is excellent, treatment time is short and morbidity is minimal

  14. In uncertainty we trust: a median voter model with risk aversion

    Directory of Open Access Journals (Sweden)

    Pavel A. Yakovlev

    2011-12-01

    Full Text Available The principal-agent problem and uncertainty are some of the key factors affecting financial and political markets. Fear of the unknown plays an important role in human decision making, including voting. This article describes a theoretical model where voter risk aversion towards uncertainty gives political incumbents a significant advantage over their challengers, exacerbating the principal-agent problem between voters and legislators. The model presented predicts that a rise in voter uncertainty concerning the challenger allows the incumbent to deviate from the median voter’s policy preference without losing the election. This model reconciles the paradoxical coexistence of ideological shirking and high incumbent reelection rates without abandoning the elegant median voter framework.

  15. Treatment time and occlusal outcome of orthognathic therapy in the East of England region.

    Science.gov (United States)

    Jeremiah, Huw G; Cousley, Richard R; Newton, Tim; Abela, Stefan

    2012-09-01

    To evaluate the process of combined orthognathic and orthodontic care. To identify factors that affect treatment time and percentage Peer Assessment Rating (PAR) reduction, and the PAR efficiency factor for such cases. Retrospective multi centre study of patients who underwent orthognathic treatment in the East of England region. Analysis of consecutive cases that underwent orthognathic surgery in 2008. Inclusion criteria included pre- and post-surgery orthodontic treatment. Ten orthodontic units submitted data for a total of 118 patients. Within the sample, 64% were class III, 35% class II/1 and 1% class II/2. Overall extraction rate, excluding third molars, was 58%. Median age at bond up was 17 years. Mean total number of orthodontic attendances was 23. Median length of pre-surgical orthodontics was 23 months and post-surgical orthodontics was 7 months. Median length of total treatment was 29 months. Mean wait for surgery was 3·6 months. Diagnosis of incisor relationship and skeletal base, transfer of operator, total number of visits, tooth extraction and treatment unit affected treatment duration. Median pre- and post-treatment PAR scores were 43 and 4, respectively. Median change in PAR score was 38·5. Median per cent reduction in PAR was 90·6%. The median PAR efficiency factor (reduction in PAR score divided by treatment time in months) was 1·24. Diagnosis of incisor relationship and skeletal base correlated with percentage reduction in PAR score. Combined orthognathic treatment was effective. Factors affecting treatment duration and percentage reduction in PAR have been established.

  16. Sosiaalisen median kehittäminen pk-yrityksissä Töpseli-verkoston avulla

    OpenAIRE

    Palander, Laura

    2010-01-01

    Tämän opinnäytetyön tarkoituksena oli selvittää, minkälaisena mahdollisuutena pk-yrittäjät kokevat sosiaalisen median ja miten he ymmärtävät sen. Läntisellä Uudellamaalla toimivia yrityksiä on osallistunut Laurea-ammattikorkeakoulun Lohjan toimipisteen Töpseli-verkostoon. Verkoston tarkoituksena on vahvistaa länsi Uudellamaalla toimivien pk-yritysten kilpailukykyä, parantamalla yrittäjien ymmärrystä sosiaalisen median tarjoamista mahdollisuuksista. Työtä varten selvitettiin myös ammattikorkea...

  17. DETERMINATION OF THE RESIDUAL OPERATING TIME OF UNRESTORABLE ELEMENT OF THE ELECTRIC POWER OBJECT AT THE WAYBALL DISTRIBUTION

    International Nuclear Information System (INIS)

    Namgaladze, D.; Gurgenidze, D.

    2007-01-01

    In practice, it is often essential to determinethe residual operating time for an unrestorable element of the electric power object which has operated without failure for a certain time. The density of probability distribution of operating time can be determined from the initial probability distribution of operating time. In this work, the relations for determination of the function of residual operating time of the unrestorable element at the exponential and Wayball distributions are analytically derived. (author)

  18. Statistical properties of the deviations of f 0 F 2 from monthly medians

    Directory of Open Access Journals (Sweden)

    Y. Tulunay

    2002-06-01

    Full Text Available The deviations of hourly f 0 F 2 from monthly medians for 20 stations in Europe during the period 1958-1998 are studied. Spectral analysis is used to show that, both for original data (for each hour and for the deviations from monthly medians, the deterministic components are the harmonics of 11 years (solar cycle, 1 year and its harmonics, 27 days and 12 h 50.49 m (2nd harmonic of lunar rotation period L 2 periodicities. Using histograms for one year samples, it is shown that the deviations from monthly medians are nearly zero mean (mean < 0.5 and approximately Gaussian (relative difference range between %10 to %20 and their standard deviations are larger for daylight hours (in the range 5-7. It is shown that the amplitude distribution of the positive and negative deviations is nearly symmetrical at night hours, but asymmetrical for day hours. The positive and negative deviations are then studied separately and it is observed that the positive deviations are nearly independent of R12 except for high latitudes, but negative deviations are modulated by R12 . The 90% confidence interval for negative deviations for each station and each hour is computed as a linear model in terms of R12. After correction for local time, it is shown that for all hours the confidence intervals increase with latitude but decrease above 60N. Long-term trend analysis showed that there is an increase in the amplitude of positive deviations from monthly means irrespective of the solar conditions. Using spectral analysis it is also shown that the seasonal dependency of negative deviations is more accentuated than the seasonal dependency of positive deviations especially at low latitudes. In certain stations, it is also observed that the 4th harmonic of 1 year corresponding to a periodicity of 3 months, which is missing in f 0 F 2 data, appears in the spectra of negative variations.

  19. Hyperparathyroidism-jaw tumor syndrome: Results of operative management.

    Science.gov (United States)

    Mehta, Amit; Patel, Dhaval; Rosenberg, Avi; Boufraqech, Myriem; Ellis, Ryan J; Nilubol, Naris; Quezado, Martha M; Marx, Stephen J; Simonds, William F; Kebebew, Electron

    2014-12-01

    Hyperparathyroidism-jaw tumor syndrome (HPT-JT) is a rare, autosomal-dominant disease secondary to germline-inactivating mutations of the tumor suppressor gene HRPT2/CDC73. The aim of the present study was to determine the optimal operative approach to parathyroid disease in patients with HPT-JT. A retrospective analysis of clinical and genetic features, parathyroid operative outcomes, and disease outcomes in 7 unrelated HPT-JT families. Seven families had 5 distinct germline HRPT2/CDC73 mutations. Sixteen affected family members (median age, 30.7 years) were diagnosed with primary hyperparathyroidism (PHPT). Fifteen of the 16 patients underwent preoperative tumor localization studies and uncomplicated bilateral neck exploration at initial operation; all were in biochemical remission at most recent follow-up. Of these patients, 31% had multiglandular involvement; 37.5% of the patients developed parathyroid carcinoma (median overall survival, 8.9 years; median follow-up, 7.4 years). Long-term follow-up showed that 20% of patients had recurrent PHPT. Given the high risk of malignancy and multiglandular involvement in our cohort, we recommend bilateral neck exploration and en bloc resection of parathyroid tumors suspicious for cancer and life-long postoperative follow-up. Published by Elsevier Inc.

  20. [Safety of repeat median sternotomy in the palliative treatment of patients with a univentricular heart].

    Science.gov (United States)

    Díliz-Nava, Héctor; Meléndez-Sagaón, Isis; Tamaríz-Cruz, Orlando; García-Benítez, Luis; Araujo-Martínez, Aric; Palacios-Macedo, Alexis

    To establish the morbidity and mortality of patients with univentricular hearts who underwent a repeat median sternotomy at the Instituto Nacional de Pediatría. A retrospective review was performed on the clinical charts of all patients who underwent a repeat median sternotomy from 2001 to 2016. Sixty-five patients underwent 76 surgeries by repeat median sternotomy. Fifty-nine patients had a first repeat median sternotomy, with a mean age of 36 months (range: 4-176 months) and a mean weight of 12.2 kg (range: 3.2-21.5 kg). Forty patients had a Glenn procedure, and 19 patients had a Fontan procedure. There were 17 patients with a second repeat median sternotomy, with a mean age of 89 months (range 48-156 months), and a mean weight of 22.7 kg (14.4-41 kg). A Fontan procedure was performed on all these 17 patients. A section of the right coronary artery with electrocardiographic changes and a right atrium tear that caused hypotension occurred during first repeat sternotomy. An aortic tear occurred during a second repeat sternotomy with massive bleeding and subsequent death. This represents 3.9% of re-entry injuries. It is concluded that repeat median sternotomy is a safe procedure. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  1. A Rank Test on Equality of Population Medians

    OpenAIRE

    Pooi Ah Hin

    2012-01-01

    The Kruskal-Wallis test is a non-parametric test for the equality of K population medians. The test statistic involved is a measure of the overall closeness of the K average ranks in the individual samples to the average rank in the combined sample. The resulting acceptance region of the test however may not be the smallest region with the required acceptance probability under the null hypothesis. Presently an alternative acceptance region is constructed such that it has the smallest size, ap...

  2. Tessier Number 30 Median Mandibular Cleft With Congenital Heart Anomalies in Qena, Egypt.

    Science.gov (United States)

    Ali, Ahmed Ali Abdelrahim

    2018-01-01

    Median cleft deformities of the lower lip and mandible are very rare congenital anomalies. Our patient had median cleft of the lower lip, mandible, and the chin with tongue duplication, ankyloglossia, and cleft strap muscles with 2 neck contracture bands. This anomaly was associated with congenital heart disease transposition of great vessels, large ventricular septal defect, and severe pulmonary stenosis. Early repair was done at 6 months to improve feeding.

  3. Evaluation of Real-time operating systems for FGC controls

    CERN Document Server

    Chalas, Konstantinos

    2015-01-01

    Power Converter Control for various experiments at CERN, is con- ducted using a machine called Function Generator Controller. The cur- rent generation of FGCs being deployed is FGC3. A certain number of FGCs require very fast and precise control, and for these systems, there is uncertainty of whether the existing hardware will be able to provide the level of determinism required. I have worked in the CCS section as a summer student on a project to study the potential of ARM-based CPUs to provide a real time behaviour fit for a future high-performance FGC4. In this paper, i will present the results of my research into real-time vari- ants of Linux and other real-time operating systems on two different ARM CPUs.

  4. [Surgery for colorectal cancer since the introduction of the Netherlands national screening programmeInvestigations into changes in number of resections and waiting times for surgery].

    Science.gov (United States)

    de Neree Tot Babberich, M P M; van der Willik, E M; van Groningen, J T; Ledeboer, M; Wiggers, T; Wouters, M W J M

    2017-01-01

    To investigate the impact of the Netherlands national colorectal cancer screening programme on the number of surgical resections for colorectal carcinoma and on waiting times for surgery. Descriptive study. Data were extracted from the Dutch Surgical Colorectal Audit. Patients with primary colorectal cancer surgery between 2011-2015 were included. The volume and median waiting times for the years 2011-2015 are described. Waiting times from first tumor positive biopsy until the operation (biopsy-operation) and first preoperative visit to the surgeon until the operation (visit-operation) are analyzed with a univariate and multivariate linear regression analysis. Separate analysis was done for visit-operation for academic and non-academic hospitals and for screening compared to non-screening patients. In 2014 there was an increase of 1469 (15%) patients compared to 2013. In 2015 this increase consisted of 1168 (11%) patients compared to 2014. In 2014 and 2015, 1359 (12%) and 3111 (26%) patients were referred to the surgeon through screening, respectively. The median waiting time of biopsy-operation significantly decreased (ß: 0.94, 95%BI) over the years 2014-2015 compared to 2011-2013. In non-academic hospitals, the waiting time visit-operation also decreased significantly (ß: 0.89, 95%BI 0.87-0.90) over the years 2014-2015 compared to 2011-2013. No difference was found in waiting times between patients referred to the surgeon through screening compared to non-screening. There is a clear increase in volume since the introduction of the colorectal cancer screening programme without an increase in waiting time until surgery.

  5. Distributed Resource Energy Analysis and Management System (DREAMS) Development for Real-time Grid Operations

    Energy Technology Data Exchange (ETDEWEB)

    Nakafuji, Dora [Hawaiian Electric Company, Honululu, HI (United States); Gouveia, Lauren [Hawaiian Electric Company, Honululu, HI (United States)

    2016-10-24

    This project supports development of the next generation, integrated energy management infrastructure (EMS) able to incorporate advance visualization of behind-the-meter distributed resource information and probabilistic renewable energy generation forecasts to inform real-time operational decisions. The project involves end-users and active feedback from an Utility Advisory Team (UAT) to help inform how information can be used to enhance operational functions (e.g. unit commitment, load forecasting, Automatic Generation Control (AGC) reserve monitoring, ramp alerts) within two major EMS platforms. Objectives include: Engaging utility operations personnel to develop user input on displays, set expectations, test and review; Developing ease of use and timeliness metrics for measuring enhancements; Developing prototype integrated capabilities within two operational EMS environments; Demonstrating an integrated decision analysis platform with real-time wind and solar forecasting information and timely distributed resource information; Seamlessly integrating new 4-dimensional information into operations without increasing workload and complexities; Developing sufficient analytics to inform and confidently transform and adopt new operating practices and procedures; Disseminating project lessons learned through industry sponsored workshops and conferences;Building on collaborative utility-vendor partnership and industry capabilities

  6. Evaluation of a non-proprietary, high-tension, four-cable median barrier on level terrain.

    Science.gov (United States)

    2012-11-01

    During the last decade, the use of cable median barriers has risen dramatically. Cable barriers are often utilized in depressed medians : with widths ranging from 30 to 50 ft (9.1 to 15.2 m) and with fill slopes as steep as 4H:1V. A careful review of...

  7. Decreasing Histology Turnaround Time Through Stepwise Innovation and Capacity Building in Rwanda

    Directory of Open Access Journals (Sweden)

    Gaspard Muvugabigwi

    2017-11-01

    Full Text Available Purpose: Minimal turnaround time for pathology results is crucial for highest-quality patient care in all settings, especially in low- and middle-income countries, where rural populations may have limited access to health care. Methods: We retrospectively determined the turnaround times (TATs for anatomic pathology specimens, comparing three different modes of operation that occurred throughout the development and implementation of our pathology laboratory at the Butaro Cancer Center of Excellence in Rwanda. Before opening this laboratory, TAT was measured in months because of inconsistent laboratory operations and a paucity of in-country pathologists. Results: We analyzed 2,514 individual patient samples across the three modes of study. Diagnostic mode 1 (samples sent out of the country for analysis had the highest median TAT, with an overall time of 30 days (interquartile range [IQR], 22 to 43 days. For diagnostic mode 2 (static image telepathology, the median TAT was 14 days (IQR, 7 to 27 days, and for diagnostic mode 3 (onsite expert diagnosis, it was 5 days (IQR, 2 to 9 days. Conclusion: Our results demonstrate that telepathology is a significant improvement over external expert review and can greatly assist sites in improving their TATs until pathologists are on site.

  8. DCOS, a Real-Time Light-weight Data Centric Operating System

    NARCIS (Netherlands)

    Hofmeijer, T.J.; Dulman, S.O.; Jansen, P.G.; Havinga, Paul J.M.; Sahni, S.

    2004-01-01

    DCOS is a Data Centric lightweight Operating System for embedded devices. Despite limited energy and hardware resources, it supports a data driven architecture with provisions for dynamic loadable Modules. It combines these with Real-Time provisions based on Earliest Deadline First with a simple but

  9. DCOS, a real-time light-weight Data Centric Operating System

    NARCIS (Netherlands)

    Hofmeijer, T.J.; Dulman, S.O.; Jansen, P.G.; Havinga, Paul J.M.

    2004-01-01

    DCOS is a Data Centric lightweight Operating System for embedded devices. Despite limited energy and hardware resources, it supports a data driven architecture with provisions for dynamic loadable Modules. It combines these with Real-Time provisions based on Earliest Deadline First with a simple but

  10. Time cycle calculation procedure for the special crew during the mining mobile machine complex operation

    International Nuclear Information System (INIS)

    Shmurygin, V; Lukyanov, V; Maslovsky, A

    2015-01-01

    The relevance of the research is specified by the necessity to optimize the delft mobile tunneling equipment operation. Target of the research is tunneling time cycle justification for the special crew during the mining mobile machine complex operation. Methods of the research included the consideration of operation organization schemes in the drifting face and effective use of the mobile equipment during mine exploratory working operations. Time cycle calculation procedures for major processes have been considered. This has been done for the special crew during the mobile machine complex operations for several working faces and various organization schemes

  11. ISS Operations Cost Reductions Through Automation of Real-Time Planning Tasks

    Science.gov (United States)

    Hall, Timothy A.; Clancey, William J.; McDonald, Aaron; Toschlog, Jason; Tucker, Tyson; Khan, Ahmed; Madrid, Steven (Eric)

    2011-01-01

    In 2007 the Johnson Space Center s Mission Operations Directorate (MOD) management team challenged their organizations to find ways to reduce the cost of operations for supporting the International Space Station (ISS) in the Mission Control Center (MCC). Each MOD organization was asked to define and execute projects that would help them attain cost reductions by 2012. The MOD Operations Division Flight Planning Branch responded to this challenge by launching several software automation projects that would allow them to greatly improve console operations and reduce ISS console staffing and intern reduce operating costs. These tasks ranged from improving the management and integration mission plan changes, to automating the uploading and downloading of information to and from the ISS and the associated ground complex tasks that required multiple decision points. The software solutions leveraged several different technologies including customized web applications and implementation of industry standard web services architecture; as well as engaging a previously TRL 4-5 technology developed by Ames Research Center (ARC) that utilized an intelligent agent-based system to manage and automate file traffic flow, archive data, and generate console logs. These projects to date have allowed the MOD Operations organization to remove one full time (7 x 24 x 365) ISS console position in 2010; with the goal of eliminating a second full time ISS console support position by 2012. The team will also reduce one long range planning console position by 2014. When complete, these Flight Planning Branch projects will account for the elimination of 3 console positions and a reduction in staffing of 11 engineering personnel (EP) for ISS.

  12. Operative outcomes of conventional specimen radiography versus in-operating room specimen radiography in radioactive seed-localized segmental mastectomies.

    Science.gov (United States)

    Rhee, Daniel; Pockaj, Barbara; Wasif, Nabil; Stucky, Chee-Chee; Pizzitola, Victor; Giurescu, Marina; Patel, Bhavika; McCarthy, Janice; Gray, Richard

    2018-01-01

    In-operating room specimen radiography (ORSR) has not been studied among women undergoing radioactive seed localization (RSL) for breast cancer surgery and had the potential to decrease operative time and perhaps improve intraoperative margin management. One hundred consecutive RSL segmental mastectomies among 98 patients using ORSR were compared to 100 consecutive segmental mastectomies among 98 patients utilizing conventional radiography (CSR) prior to the initiation of ORSR from December 2013 to January 2015 after radioactive seed localization. Final pathologic margins were considered to be 10 mm for all cases of no residual disease after biopsy or neoadjuvant therapy, but such patients were excluded from analyses involving tumor size. All patients' specimens were subjected to intraoperative pathologic consultation in addition to ORSR or CSR. The median age of the cohort was 65 years (range 36-97), and the median tumor size was 1 cm. There were no differences between the ORSR and CSR groups in age, tumor size, percentage of cases with only DCIS, and percentage of cases with microcalcifications. The ORSR group had a statistically significant lower BMI. Mean operative time from cut-to-close was not significantly different (ORSR 77 min, SD 24.8 vs CSR 76 min, SD 24.8, p = 0.75). There was no statistical difference in mean closest final pathologic margin (4.99 mm, SD 3.3 vs 4.88 mm, SD 3.5, p = 0.9). The percentage undergoing intraoperative margin re-excision (ORSR 40%, CR 47%, p = 0.31) and the mean total number of margins excised intraoperatively (ORSR 0.9, CR 1.0 p = 0.65) were similar. The rate of any margin CSR; this difference was not statistically significant (p = 0.25). The mean ratio of segmental mastectomy volume to maximum tumor diameter was less for ORSR (82.7cm2 vs 139.4cm2, p = 0.014). ORSR for RSL breast surgery, in the setting of routine intraoperative pathology consultation, does not significantly impact operative time, the rate or

  13. New England observed and predicted median July stream/river temperature points

    Data.gov (United States)

    U.S. Environmental Protection Agency — The shapefile contains points with associated observed and predicted median July stream/river temperatures in New England based on a spatial statistical network...

  14. New England observed and predicted median August stream/river temperature points

    Data.gov (United States)

    U.S. Environmental Protection Agency — The shapefile contains points with associated observed and predicted median August stream/river temperatures in New England based on a spatial statistical network...

  15. A Study of Time Response for Safety-Related Operator Actions in Non-LOCA Safety Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Seok; Lee, Sang Seob; Park, Min Soo; Lee, Gyu Cheon; Kim, Shin Whan [KEPCO E and C Company, Daejeon (Korea, Republic of)

    2014-10-15

    The classification of initiating events for safety analysis report (SAR) chapter 15 is categorized into moderate frequency events (MF), infrequent events (IF), and limiting faults (LF) depending on the frequency of its occurrence. For the non-LOCA safety analysis with the purpose to get construction or operation license, however, it is assumed that the operator response action to mitigate the events starts at 30 minutes after the initiation of the transient regardless of the event categorization. Such an assumption of corresponding operator response time may have over conservatism with the MF and IF events and results in a decrease in the safety margin compared to its acceptance criteria. In this paper, the plant conditions (PC) are categorized with the definitions in SAR 15 and ANS 51.1. Then, the consequence of response for safety-related operator action time is determined based on the PC in ANSI 58.8. The operator response time for safety analysis regarding PC are reviewed and suggested. The clarifying alarm response procedure would be required for the guideline to reduce the operator response time when the alarms indicate the occurrence of the transient.

  16. A Systematic Multi-Time Scale Solution for Regional Power Grid Operation

    Science.gov (United States)

    Zhu, W. J.; Liu, Z. G.; Cheng, T.; Hu, B. Q.; Liu, X. Z.; Zhou, Y. F.

    2017-10-01

    Many aspects need to be taken into consideration in a regional grid while making schedule plans. In this paper, a systematic multi-time scale solution for regional power grid operation considering large scale renewable energy integration and Ultra High Voltage (UHV) power transmission is proposed. In the time scale aspect, we discuss the problem from month, week, day-ahead, within-day to day-behind, and the system also contains multiple generator types including thermal units, hydro-plants, wind turbines and pumped storage stations. The 9 subsystems of the scheduling system are described, and their functions and relationships are elaborated. The proposed system has been constructed in a provincial power grid in Central China, and the operation results further verified the effectiveness of the system.

  17. The mean, the median, and the St. Petersburg paradox.

    Science.gov (United States)

    Hayden, Benjamin Y; Platt, Michael L

    2009-06-01

    The St. Petersburg Paradox is a famous economic and philosophical puzzle that has generated numerous conflicting explanations. To shed empirical light on this phenomenon, we examined subjects' bids for one St. Petersburg gamble with a real monetary payment. We found that bids were typically lower than twice the smallest payoff, and thus much lower than is generally supposed. We also examined bids offered for several hypothetical variants of the St. Petersburg Paradox. We found that bids were weakly affected by truncating the gamble, were strongly affected by repeats of the gamble, and depended linearly on the initial "seed" value of the gamble. One explanation, which we call the median heuristic , strongly predicts these data. Subjects following this strategy evaluate a gamble as if they were taking the median rather than the mean of the payoff distribution. Finally, we argue that the distribution of outcomes embodied in the St. Petersburg paradox is so divergent from the Gaussian form that the statistical mean is a poor estimator of expected value, so that the expected value of the St. Petersburg gamble is undefined. These results suggest that this classic paradox has a straightforward explanation rooted in the use of a statistical heuristic.

  18. PROJECTIONS OF DORSAL AND MEDIAN RAPHE NUCLEI TO DORSAL AND VENTRAL STRIATUM

    Directory of Open Access Journals (Sweden)

    G. R. Hassanzadeh G. Behzadi

    2007-08-01

    Full Text Available The ascending serotonergic projections are derived mainly from mesencephalic raphe nuclei. Topographical projections from mesencephalic raphe nuclei to the striatum were examined in the rat by the retrograde transport technique of HRP (horseradish peroxidase. In 29 rats stereotaxically injection of HRP enzyme were performed in dorsal and ventral parts of striatum separately. The extent of the injection sites and distribution of retrogradely labeled neuronal cell bodies were drawed on representative sections using a projection microscope. Following ipsilateral injection of HRP into the dorsal striatum, numerous labeled neurons were seen in rostral portion of dorsal raphe (DR nucleus. In the same level the cluster of labeled neurons were hevier through caudal parts of DR. A few neurons were also located in lateral wing of DR. More caudally some labeled neurons were found in lateral, medial line of DR. In median raphe nucleus (MnR the labeled neurons were scattered only in median portion of this nucleus. The ipsilateral injection of HRP into the ventral region of striatum resulted on labeling of numerous neurons in rostral, caudal and lateral portions of DR. Through the caudal extension of DR on 4th ventricle level, a large number of labeled neurons were distributed along the ventrocaudal parts of DR. In MnR, labeled neurons were observed only in median part of this nucleus. These findings suggest the mesencephalic raphe nuclei projections to caudo-putamen are topographically organized. In addition dorsal and median raphe nuclei have a stronger projection to the ventral striatum.

  19. Implementation and evaluation of an ordered subsets reconstruction algorithm for transmission PET studies using median root prior and inter-update median filtering

    International Nuclear Information System (INIS)

    Bettinardi, V.; Gilardi, M.C.; Fazio, F.; Alenius, S.; Ruotsalainen, U.; Numminen, P.; Teraes, M.

    2003-01-01

    An ordered subsets (OS) reconstruction algorithm based on the median root prior (MRP) and inter-update median filtering was implemented for the reconstruction of low count statistics transmission (TR) scans. The OS-MRP-TR algorithm was evaluated using an experimental phantom, simulating positron emission tomography (PET) whole-body (WB) studies, as well as patient data. Various experimental conditions, in terms of TR scan time (from 1 h to 1 min), covering a wide range of TR count statistics were evaluated. The performance of the algorithm was assessed by comparing the mean value of the attenuation coefficient (MVAC) of known tissue types and the coefficient of variation (CV) for low-count TR images, reconstructed with the OS-MRP-TR algorithm, with reference values obtained from high-count TR images reconstructed with a filtered back-projection (FBP) algorithm. The reconstructed OS-MRP-TR images were then used for attenuation correction of the corresponding emission (EM) data. EM images reconstructed with attenuation correction generated by OS-MRP-TR images, of low count statistics, were compared with the EM images corrected for attenuation using reference (high statistics) TR data. In all the experimental situations considered, the OS-MRP-TR algorithm showed: (1) a tendency towards a stable solution in terms of MVAC; (2) a difference in the MVAC of within 5% for a TR scan of 1 min reconstructed with the OS-MRP-TR and a TR scan of 1 h reconstructed with the FBP algorithm; (3) effectiveness in noise reduction, particularly for low count statistics data [using a specific parameter configuration the TR images reconstructed with OS-MRP-TR(1 min) had a lower CV than the corresponding TR images of a 1-h scan reconstructed with the FBP algorithm]; (4) a difference of within 3% between the mean counts in the EM images attenuation corrected using the OS-MRP-TR images of 1 min and the mean counts in the EM images attenuation corrected using the OS-MRP-TR images of 1 h; (5

  20. Digitaalisen markkinoinnin ja sosiaalisen median hyödyntäminen kampaamoalalla : Pienyritykset

    OpenAIRE

    Myllymäki, Hanna

    2016-01-01

    Tämän opinnäytetyön aiheena oli digitaalisen markkinoinnin ja sosiaalisen median hyödyntäminen kampaamoalalla, erityisesti pienissä yrityksissä. Tavoitteena oli opastaa lukijaa ymmärtämään digitaalisen markkinoinnin ja sosiaalisen median keskeisimmät perusteet ja antaa neuvoja parturi-kampaamoalan yrittäjälle, joka ei ole vielä huomioinut tai osannut hyödyntää niiden työkaluja. Työn teoriaosuudessa käsiteltiin mitä markkinointiviestintä on ja mitä sosiaalisen media on. Tämän lisäksi käsit...

  1. From dynamical systems with time-varying delay to circle maps and Koopman operators

    Science.gov (United States)

    Müller, David; Otto, Andreas; Radons, Günter

    2017-06-01

    In this paper, we investigate the influence of the retarded access by a time-varying delay on the dynamics of delay systems. We show that there are two universality classes of delays, which lead to fundamental differences in dynamical quantities such as the Lyapunov spectrum. Therefore, we introduce an operator theoretic framework, where the solution operator of the delay system is decomposed into the Koopman operator describing the delay access and an operator similar to the solution operator known from systems with constant delay. The Koopman operator corresponds to an iterated map, called access map, which is defined by the iteration of the delayed argument of the delay equation. The dynamics of this one-dimensional iterated map determines the universality classes of the infinite-dimensional state dynamics governed by the delay differential equation. In this way, we connect the theory of time-delay systems with the theory of circle maps and the framework of the Koopman operator. In this paper, we extend our previous work [A. Otto, D. Müller, and G. Radons, Phys. Rev. Lett. 118, 044104 (2017), 10.1103/PhysRevLett.118.044104] by elaborating the mathematical details and presenting further results also on the Lyapunov vectors.

  2. Regulatory Approach to Safety of Long Time Operating Research Reactors in Russia

    Energy Technology Data Exchange (ETDEWEB)

    Sapozhnikov, Alexander [Industrial and Nuclear Supervision Service, Moscow (Russian Federation)

    2013-07-01

    In the Russian Federation more than 60% of operating Nuclear Research Facilities (NRFs) are of age over 30 years old or their usage exceeds originally conceived continuous operation. In this regard, important areas of regulatory body activity are: 1) a systematic assessment of the actual state of structures, systems and components (SSCs) important to safety, 2) control of implementation of organizational and technical measures to mitigate ageing impact on the basis of programmes to manage reliability (service life) of SSCs, and 3) issues of facility modification/reconstruction in line with up-to-day safety requirements. The practice of licensing NRFs with long operating times shows that the national regulations are generally in compliance with IAEA recommendations for ageing management of research reactors. In operating organizations, the ageing management is being effectively provided as a part of the integrated management system for NRFs, including the monitoring of the reliability of SSCs, a methodology to detect their ageing, reporting and investigation of events, analysis of their root causes, and measures to prevent and mitigate ageing effects to safety. The report outlines a good practice of safety regulation of NRFs with long operating times and based on lessons learned from experience, including challenges for future improvement of ageing management.

  3. Regulatory Approach to Safety of Long Time Operating Research Reactors in Russia

    International Nuclear Information System (INIS)

    Sapozhnikov, Alexander

    2013-01-01

    In the Russian Federation more than 60% of operating Nuclear Research Facilities (NRFs) are of age over 30 years old or their usage exceeds originally conceived continuous operation. In this regard, important areas of regulatory body activity are: 1) a systematic assessment of the actual state of structures, systems and components (SSCs) important to safety, 2) control of implementation of organizational and technical measures to mitigate ageing impact on the basis of programmes to manage reliability (service life) of SSCs, and 3) issues of facility modification/reconstruction in line with up-to-day safety requirements. The practice of licensing NRFs with long operating times shows that the national regulations are generally in compliance with IAEA recommendations for ageing management of research reactors. In operating organizations, the ageing management is being effectively provided as a part of the integrated management system for NRFs, including the monitoring of the reliability of SSCs, a methodology to detect their ageing, reporting and investigation of events, analysis of their root causes, and measures to prevent and mitigate ageing effects to safety. The report outlines a good practice of safety regulation of NRFs with long operating times and based on lessons learned from experience, including challenges for future improvement of ageing management

  4. Impact of the European Working Time Directive (EWTD) on the operative experience of surgery residents.

    Science.gov (United States)

    Hopmans, Cornelis J; den Hoed, Pieter T; van der Laan, Lijckle; van der Harst, Erwin; van der Elst, Maarten; Mannaerts, Guido H H; Dawson, Imro; Timman, Reinier; Wijnhoven, Bas P L; IJzermans, Jan N M

    2015-04-01

    In Europe and the United States, work hour restrictions are considered to be particularly burdensome for residents in surgery specialties. The aim of this study was to examine whether reduction of the work week to 48 hours resulting from the implementation of the European Working Time Directive has affected the operative experience of surgery residents. This study was conducted in a general surgery training region in the Netherlands, consisting of 1 university hospital and 6 district training hospitals. Operating records summarizing the surgical procedures performed as "primary surgeon" in the operating theater for different grades of surgeons were retrospectively analyzed for the period 2005-2012 by the use of linear regression models. Operative procedures performed by residents were considered the main outcome measure. In total, 235,357 operative procedures were performed, including 47,458 (20.2%) in the university hospital and 187,899 (79.8%) in the district training hospitals (n = 5). For residents in the university hospital, the mean number of operative procedures performed per 1.0 full-time equivalent increased from 128 operations in 2005 to 204 operations in 2012 (P = .001), whereas for residents in district training hospitals, no substantial differences were found over time. The mean (±SD) operative caseload of 64 residents who completed the 6-year training program between 2005 and 2012 was 1,391 ± 226 (range, 768-1856). A comparison of the operative caseload according to year of board-certification showed no difference. Implementation of the European Working Time Directive has not affected adversely the number of surgical procedures performed by residents within a general surgical training region in the Netherlands. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. On the definition of the time evolution operator for time-independent Hamiltonians in non-relativistic quantum mechanics

    Science.gov (United States)

    Amaku, Marcos; Coutinho, Francisco A. B.; Masafumi Toyama, F.

    2017-09-01

    The usual definition of the time evolution operator e-i H t /ℏ=∑n=0∞1/n ! (-i/ℏHt ) n , where H is the Hamiltonian of the system, as given in almost every book on quantum mechanics, causes problems in some situations. The operators that appear in quantum mechanics are either bounded or unbounded. Unbounded operators are not defined for all the vectors (wave functions) of the Hilbert space of the system; when applied to some states, they give a non-normalizable state. Therefore, if H is an unbounded operator, the definition in terms of the power series expansion does not make sense because it may diverge or result in a non-normalizable wave function. In this article, we explain why this is so and suggest, as an alternative, another definition used by mathematicians.

  6. Intelligent control for modeling of real-time reservoir operation, part II: artificial neural network with operating rule curves

    Science.gov (United States)

    Chang, Ya-Ting; Chang, Li-Chiu; Chang, Fi-John

    2005-04-01

    To bridge the gap between academic research and actual operation, we propose an intelligent control system for reservoir operation. The methodology includes two major processes, the knowledge acquired and implemented, and the inference system. In this study, a genetic algorithm (GA) and a fuzzy rule base (FRB) are used to extract knowledge based on the historical inflow data with a design objective function and on the operating rule curves respectively. The adaptive network-based fuzzy inference system (ANFIS) is then used to implement the knowledge, to create the fuzzy inference system, and then to estimate the optimal reservoir operation. To investigate its applicability and practicability, the Shihmen reservoir, Taiwan, is used as a case study. For the purpose of comparison, a simulation of the currently used M-5 operating rule curve is also performed. The results demonstrate that (1) the GA is an efficient way to search the optimal input-output patterns, (2) the FRB can extract the knowledge from the operating rule curves, and (3) the ANFIS models built on different types of knowledge can produce much better performance than the traditional M-5 curves in real-time reservoir operation. Moreover, we show that the model can be more intelligent for reservoir operation if more information (or knowledge) is involved.

  7. Median sep and blink reflex in thyroid diseases.

    Science.gov (United States)

    Oflazoğlu, B; Somay, G; Us, O; Surardamar, A; Tanridağ, T

    2006-11-01

    Pathological disturbances of thyroid hormones is associated with central and peripheral nervous system disturbances. The aim of this study is to evaluate median nerve stimulated somatosensory evoked potential (SEP) and blink reflex of thyroid patients (hypo and hyperthyroidism). Median SEP was performed in 40 patients (21 with hyperthyroidism and 19 with hypothyroidism). We evaluated the latencies of N9, N11, N13, P9, P11, P14, N20 and P25 waves and the N9-N20, N9-N13, N13-N20 and P14-N20 interpeak latencies. We compared the results of patients with the control group (26 persons). We found that the N20 latency was longer in patients with hyperthyroidism than in the control group and the difference was statistically significant. There was not any statistically significant difference regarding the N9, N11, N13, P9, P11, P14, N20 and P25 latencies and the N9-N20, N9-N13, N13-N20 and P14-N20 interpeak latencies between hypothyroid patients and controls. We performed the blink reflex study in 28 of 40 patients (14 patients with hyperthyroidism and 14 patients with hypothyroidism). Comparing the R1, R2, CR2 (contralateral R2) latencies and durations of the patients and controls, we found that R2 and CR2 duration was shorter in patients with hyperthyroidism. This difference was statistically significant.

  8. Anticipation of lead time performance in supply chain operations planning

    NARCIS (Netherlands)

    Jansen, M.M.; Kok, de A.G.; Fransoo, J.C.

    2009-01-01

    Whilst being predominantly used in practice, linear and mixed integer programming models for Supply Chain Operations Planning (SCOP) are not well suited for modeling the relationship between the release of work to a production unit and its output over time. In this paper we propose an approach where

  9. Radiofrequency catheter ablation: Relationship between fluoroscopic time and skin doses according to diagnoses. Basis to establish a quality assurance programme

    International Nuclear Information System (INIS)

    Cotelo, E.; Pouso, J.; Reyes, W.

    2001-01-01

    Radiofrequency Cardiac Catheter Ablation is an Interventional Radiology procedure of great complexity because the cardiologist needs a simultaneous evaluation of fluoroscopic images and electrophysiologic information. Therefore, the procedure typically involves extended fluoroscopic time that may cause radiation-skin injures to patients. Skin doses depend on many factors: equipment design features and its proper use, cardiologist practice, fluoroscopic time, irradiated areas, application of radiation protection recommendations, etc. We evaluate fluoroscopic time in relation to pathology and we estimate skin doses on 233 procedures at the Electrophysiology Laboratory in Casa de Galicia, Montevideo, Uruguay. Significant differences among the medians of fluoroscopic time were found in those procedures depending on diagnoses and results. Higher fluoroscopic time was found in flutter and auricular tachycardia (median was 83 minutes, p=0.0001). In successful procedures (almost 90%), median skin doses was 2.0 Grays (p=0.0001). On the basis of records information, the standard operating procedure and the clinical protocol, expanding close cooperation between the cardiologists and the experts in Radiation Protection will secure the establishment of an Assurance Quality Program. (author)

  10. Effect of finger motion on transverse median nerve movement in the carpal tunnel.

    Science.gov (United States)

    Kang, Hyo Jung; Yoon, Joon Shik

    2016-10-01

    We used ultrasonography (US) to investigate the effects of finger motion on movement of the median nerve in patients with carpal tunnel syndrome (CTS) and the correlation between these US parameters and CTS severity. Ultrasonographic measures were performed in 23 control wrists and 22 CTS wrists in women. During first through third finger flexion and grip motion, median nerve movements were obtained using US and a tracing program. Nerve movements during third finger flexion in the dorsopalmar axis and grip motion in both axes, and during second finger flexion in the radioulnar axis, differed significantly between the control and CTS groups. US parameters correlated negatively with cross-sectional area. This study shows that transverse median nerve movements decreased during grip using US and correlated negatively with CTS severity. Muscle Nerve, 2016 Muscle Nerve 54: -, 2016 Muscle Nerve 54: 738-742, 2016. © 2016 Wiley Periodicals, Inc.

  11. Ureteral catheters for colorectal surgery: Influence on operative times and complication outcomes: An observational study

    Directory of Open Access Journals (Sweden)

    Julio T. Chong

    2018-03-01

    Full Text Available Purpose: Placement of pre-operative ureteral catheters for colorectal surgery can aid in the identification of ureteral injuries. This study investigates whether simultaneous ureteral catheterization with surgery skin preparation can minimize operating room times without increasing post-operative complications. Materials and Methods: Patients undergoing simultaneous colorectal surgery skin preparation and placement of pre-operative ureteral catheters (n=21 were compared to those who underwent these events sequentially (n=28. Operative time-points of anesthesia ready (AR, surgery procedure start (PS, dorsal lithotomy and catheter insertion (CI times were compared to assess for differences between groups. Complications were compared between groups. Results: There were no differences in age, gender, body mass index (BMI, American Society of Anesthesiologists (ASA, comorbidities, current procedure terminology (CPT or International Classification of Diseases, 9th revision (ICD-9 codes between groups. Simultaneous catheterization saved 11.82 minutes of operative time between CI to PS (p=0.005, t-test. There was a significant difference in mean time between CI to PS (11.82 minutes, p=0.008 between simultaneous and sequential ureteral catheterization groups in a linear regression multivariate analysis controlling for age, BMI, CPT and ICD-9 codes. There were 4 complications in the simultaneous (19% and 3 in the sequential group (11% (p=0.68. Conclusions: Ureteral catheterization and colorectal surgery skin preparation in a simultaneous fashion decreases the time between CI and PS without significant increase in complications. Mean time saved with simultaneous ureteral catheterization was 11.82 minutes per case. Simultaneous ureteral catheterization may be an option in colorectal surgery and may result in cost savings without additional complications.

  12. Median Arcuate Ligament Syndrome: A Single-Center Experience with 23 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Nasr, Layla A. [American University of Beirut Medical Center, Division of Interventional Radiology, Department of Radiology (Lebanon); Faraj, Walid G. [American University of Beirut Medical Center, Department of Surgery (Lebanon); Al-Kutoubi, Aghiad [American University of Beirut Medical Center, Division of Interventional Radiology, Department of Radiology (Lebanon); Hamady, Mohamad [Imperial College-London Faculty of Medicine, Division of Interventional Radiology, Department of Radiology (United Kingdom); Khalifeh, Mohamad; Hallal, Ali; Halawani, Hamzeh M. [American University of Beirut Medical Center, Department of Surgery (Lebanon); Wazen, Joelle; Haydar, Ali A., E-mail: ah24@aub.edu.lb [American University of Beirut Medical Center, Division of Interventional Radiology, Department of Radiology (Lebanon)

    2017-05-15

    BackgroundMedian arcuate ligament syndrome (MALS) is a rare entity that occurs when the median arcuate ligament of the diaphragm is low-lying, causing a compression to the underlying celiac trunk. We reviewed the vascular changes associated with MALS in an effort to emphasize the seriousness of this disease and the complications that may result.MethodsThis is a retrospective descriptive analysis of 23 consecutive patients diagnosed with MALS between January 1, 2012 and December 31, 2015 at a tertiary medical center. Computed tomographic (CT) scans, medical records, and patient follow-up were reviewed.ResultsThe number of patients included herein was 23. The median age was 56 years (17–83). Sixteen patients (69.6%) had a significant arterial collateral circulation. Eleven patients (47.8%) were found to have visceral artery aneurysms; 4 patients (36.4%) bled secondary to aneurysm rupture. All ruptured aneurysms were treated with endovascular approach. The severity of the hemodynamic changes appears to be greater with complete occlusion,ConclusionsMALS causes pathological hemodynamic changes within the abdominal vasculature. Follow-up is advised for patients who develop a collateral circulation. Resulting aneurysms should preferably be treated when the size ratio approaches three. Treatment of these aneurysms can be done via an endovascular approach coupled with possible celiac artery decompression to restore physiologic blood flow.

  13. Real Time Space Weather Support for Chandra X-ray Observatory Operations

    Science.gov (United States)

    O'Dell, S. L.; Miller, S.; Minow, J. I.; Wolk, S.; Aldcroft, T. L.; Spitzbart, B. D.; Swartz, D. A.

    2012-12-01

    NASA launched the Chandra X-ray Observatory in July 1999. Soon after first light in August 1999, however, degradation in the energy resolution and charge transfer efficiency of the Advanced CCD Imaging Spectrometer (ACIS) x-ray detectors was observed. The source of the degradation was quickly identified as radiation damage in the charge-transfer channel of the front-illuminated CCDs, by weakly penetrating ("soft", 100-500 keV) protons as Chandra passed through the Earth's radiation belts and ring currents. As soft protons were not considered a risk to spacecraft health before launch, the only on-board radiation monitoring system is the Electron, Proton, and Helium Instrument (EPHIN) which was included on Chandra with the primary purpose of monitoring energetic solar particle events. Further damage to the ACIS detector has been successfully mitigated through a combination of careful mission planning, autonomous on-board radiation protection, and manual intervention based upon real-time monitoring of the soft-proton environment. The AE-8 and AP-8 trapped radiation models and Chandra Radiation Models are used to schedule science operations in regions of low proton flux. EPHIN has been used as the primary autonomous in-situ radiation trigger; but, it is not sensitive to the soft protons that damage the front-illuminated CCDs. Monitoring of near-real-time space weather data sources provides critical information on the proton environment outside the Earth's magnetosphere due to solar proton events and other phenomena. The operations team uses data from the Geostationary Operational Environmental Satellites (GOES) to provide near-real-time monitoring of the proton environment; however, these data do not give a representative measure of the soft-proton (real-time data provided by NOAA's Space Weather Prediction Center. This presentation will discuss radiation mitigation against proton damage, including models and real-time data sources used to protect the ACIS detector

  14. Case Report: A true median facial cleft (crano-facial dysraphia ...

    African Journals Online (AJOL)

    Case Report: A true median facial cleft (crano-facial dysraphia, atessier type O) in Bingham University Teaching Hospital, Jos. ... Patient had a multidisciplinary care by the obstetrician, Neonatologist, anesthesiologist and the plastic surgery team who scheduled a soft tissue repair of the upper lip defect, columella and ...

  15. SOSIAALISEN MEDIAN HYÖDYNTÄMINEN KUNTOKESKUS BALANCEN MARKKINOINNISSA

    OpenAIRE

    Arvola, Timo

    2011-01-01

    Tässä opinnäytetyössä oli kyse kehittämistehtävästä. Kehittämistehtävän tarkoitus oli tarkastella voiko Kuntokes-kus Balance hyödyntää sosiaalista mediaa markkinoinnissaan. Empiirisessä osassa on ohje Facebook-sivun luomi-seen. Teorian alussa tarkastellaan sosiaalista mediaa käsitteenä. Sosiaalisesta mediasta käsitteenä siirrytään sosiaalisen median sovelluksiin ja niiden ominaisuuksiin. Sovelluksista käsitellään Facebook, Youtube, Twitter, Wikipedia, blogit, Movescount ja HeiaHeia. ...

  16. Nuorten sosiaalisen median käyttö tiedonhankinnassa

    OpenAIRE

    Simolin, Annina

    2017-01-01

    Opinnäytetyön toimeksiantajana on Hämeen ammattikorkeakoulun strateginen viestintä, joka vastaa muun muassa opiskelijahankinnasta. HAMKilla on tällä hetkellä käytössään useita sosiaalisen median kanavia, ja työllä haluttiin selvittää mistä kanavista ja mitä tietoa nuoret erityisesti hakevat jatko-opintoja suunnitellessaan. Lisäksi haluttiin selvittää miten nuoret haluavat itse olla yhteydessä oppilaitoksiin hakuaikana. Teoriaosiossa on käsitelty nuorten mediakäyttäytymistä sekä useita sosiaal...

  17. Evolving from Planning and Scheduling to Real-Time Operations Support: Design Challenges

    Science.gov (United States)

    Marquez, Jessica J.; Ludowise, Melissa; McCurdy, Michael; Li, Jack

    2010-01-01

    Versions of Scheduling and Planning Interface for Exploration (SPIFe) have supported a variety of mission operations across NASA. This software tool has evolved and matured over several years, assisting planners who develop intricate schedules. While initially conceived for surface Mars missions, SPIFe has been deployed in other domains, where people rather than robotic explorers, execute plans. As a result, a diverse set of end-users has compelled growth in a new direction: supporting real-time operations. This paper describes the new needs and challenges that accompany this development. Among the key features that have been built for SPIFe are current time indicators integrated into the interface and timeline, as well as other plan attributes that enable execution of scheduled activities. Field tests include mission support for the Lunar CRater Observation and Sensing Satellite (LCROSS), NASA Extreme Environment Mission Operations (NEEMO) and Desert Research and Technology Studies (DRATS) campaigns.

  18. Innovative Telemonitoring System for Cardiology: From Science to Routine Operation

    Science.gov (United States)

    Kastner, P.; Morak, J.; Modre, R.; Kollmann, A.; Ebner, C.; Fruhwald, FM.; Schreier, G.

    2010-01-01

    Objective Results of the Austrian MOBITEL (MOBIle phone based TELemonitoring for heart failure patients) trial indicate that home-based telemonitoring improves outcome of chronic heart failure (CHF) patients and reduces both frequency and duration of hospitalizations. Based on lessons learned, we assessed the weak points to clear the way for routine operations. Methods We analyzed the system with respect to recommendations of the ESC Guidelines and experiences gained throughout the trial to identify potential improvements. The following components have been identified: a patient terminal with highest usability, integrated way to document drug-intake and well-being, and automated event detection for worsening of CHF. As a consequence the system was extended by Near Field Communication (NFC) technology and by an event management tool. Results Usability evaluation with 30 adults (14f, median 51y. IQR[45-65]) showed that 21 (8f) were able to immediately operate the system after reading a step-by-step manual. Eight (6f) needed one time demonstration and one man (80y) failed to operate the blood pressure meter. Routine operation of the revised system started in March 2009. Within 9 months, 15 patients (4f, median 74y. IQR[71-83], all NYHA-III) transmitted 17,149 items. 43 events were detected because of body weight gain of more then 2kg within 2 days. 49 therapy adjustments were documented. Three patients stopped using the system, two (1f) because of non-compliance and one (m, 82y) because of death. Overall, the rate of adherence to daily data transfer was 78%. Conclusion First results confirm the applicability of the revised telemonitoring system in routine operation. PMID:23616835

  19. Median effective dose of isoflurane, sevoflurane, and desflurane in green iguanas.

    Science.gov (United States)

    Barter, Linda S; Hawkins, Michelle G; Brosnan, Robert J; Antognini, Joseph F; Pypendop, Bruno H

    2006-03-01

    To determine the median effective dose (ED(50); equivalent to the minimum alveolar concentration [MAC]) of isoflurane, sevoflurane, and desflurane for anesthesia in iguanas. 6 healthy adult green iguanas. In unmedicated iguanas, anesthesia was induced and maintained with each of the 3 volatile drugs administered on separate days according to a Latin square design. Iguanas were endotracheally intubated, mechanically ventilated, and instrumented for cardiovascular and respiratory measurements. During each period of anesthesia, MAC was determined in triplicate. The mean value of 2 consecutive expired anesthetic concentrations, 1 that just permitted and 1 that just prevented gross purposeful movement in response to supramaximal electrical stimulus, and that were not different by more than 15%, was deemed the MAC. Mean +/- SD values for the third MAC determination for isoflurane, sevoflurane, and desflurane were 1.8 +/- 0.3%, 3.1 +/- 1.0%, and 8.9 +/- 2.1% of atmospheric pressure, respectively. The MAC for all inhaled agents was, on average, 22% greater for the first measurement than for the third measurement. Over time, MACs decreased for all 3 agents. Final MAC measurements were similar to values reported for other species. The decrease in MACs over time may be at least partly explained by limitations of anesthetic uptake and distribution imposed by the reptilian cardiorespiratory system. Hence, for a constant end-tidal anesthetic concentration in an iguana, the plane of anesthesia may deepen over time, which could contribute to increased morbidity during prolonged procedures.

  20. Operation Modes and Control Schemes for Internet-Based Teleoperation System with Time Delay

    Institute of Scientific and Technical Information of China (English)

    曾庆军; 宋爱国

    2003-01-01

    Teleoperation system plays an important role in executing task under hazard environment. As the computer networks such as the Internet are being used as the communication channel of teleoperation system, varying time delay causes the overall system unstable and reduces the performance of transparency. This paper proposed twelve operation modes with different control schemes for teleoperation on the Internet with time delay. And an optimal operation mode with control scheme was specified for teleoperation with time delay, based on the tradeoff between passivity and transparency properties. It experimentally confirmed the validity of the proposed optimal mode and control scheme by using a simple one DOF master-slave manipulator system.

  1. A time-dependent event tree technique for modelling recovery operations

    International Nuclear Information System (INIS)

    Kohut, P.; Fitzpatrick, R.

    1991-01-01

    The development of a simplified time dependent event tree methodology is presented. The technique is especially applicable to describe recovery operations in nuclear reactor accident scenarios initiated by support system failures. The event tree logic is constructed using time dependent top events combined with a damage function that contains information about the final state time behavior of the reactor core. Both the failure and the success states may be utilized for the analysis. The method is illustrated by modeling the loss of service water function with special emphasis on the RCP [reactor coolant pump] seal LOCA [loss of coolant accident] scenario. 5 refs., 2 figs., 2 tabs

  2. Etiology and mechanisms of ulnar and median forearm nerve injuries

    Directory of Open Access Journals (Sweden)

    Puzović Vladimir

    2015-01-01

    Full Text Available Bacgraund/Aim. Most often injuries of brachial plexus and its branches disable the injured from using their arms and/or hands. The aim of this study was to investigate the etiology and mechanisms of median and ulnar forearm nerves injuries. Methods. This retrospective cohort study included 99 patients surgically treated in the Clinic of Neurosurgery, Clinical Center of Serbia, from January 1st, 2000 to December 31st, 2010. All data are obtained from the patients' histories. Results. The majority of the injured patients were male, 81 (81.8%, while only 18 (18.2% were females, both mainly with nerve injuries of the distal forearm - 75 (75.6%. Two injury mechanisms were present, transection in 85 patients and traction and contusion in 14 of the patients. The most frequent etiological factor of nerve injuries was cutting, in 61 of the patients. Nerve injuries are often associated with other injuries. In the studied patients there were 22 vascular injuries, 33 muscle and tendon injuries and 20 bone fractures. Conclusion. The majority of those patients with peripheral nerve injuries are represented in the working age population, which is a major socioeconomic problem. In our study 66 out of 99 patients were between 17 and 40 years old, in the most productive age. The fact that the majority of patients had nerve injuries of the distal forearm and that they are operated within the first 6 months after injury, promises them good functional prognosis.

  3. Study of time-critical diagnostic method for emergency operation of nuclear power plant

    International Nuclear Information System (INIS)

    Gofuku, A.; Yoshikawa, H.; Itoh, K.; Wakabayashi, J.

    1986-01-01

    In order to support the emergency operation of nuclear power plant, the method of time-critical diagnostic plant analyzer has been investigated. The conception of the emergency operation support center is proposed and two types of plant analyzer may be installed in this center. One analyzer is a real-time tracking simulation code using the observed signals and another is a fast trend-prediction code. A real-time tracking code, TOKRAC, has been developed for analyzing the PWR primary loop thermo-hydraulics at SBLOCA, and the applicability of this code was examined by the numerical experiments for the initial phase transient of both TMI-2 accident and 6% coldleg SBLOCA of a Westinghouse-type PWR plant. The results showed that fairly good tracking was carried out by TOKRAC. The CPU time of TOKRAC was about 12-14 percent of real-time

  4. On Lambda and Time Operators: the Inverse Intertwining Problem Revisited

    Science.gov (United States)

    Gómez-Cubillo, F.; Suchanecki, Z.; Villullas, S.

    2011-07-01

    An exact theory of irreversibility was proposed by Misra, Prigogine and Courbage, based on non-unitary similarity transformations Λ that intertwine reversible dynamics and irreversible ones. This would advocate the idea that irreversible behavior would originate at the microscopic level. Reversible evolution with an internal time operator have the intertwining property. Recently the inverse intertwining problem has been answered in the negative, that is, not every unitary evolution allowing such Λ-transformation has an internal time. This work contributes new results in this direction.

  5. Measuring quality indicators in the operating room: cleaning and turnover time.

    Science.gov (United States)

    Jericó, Marli de Carvalho; Perroca, Márcia Galan; da Penha, Vivian Colombo

    2011-01-01

    This exploratory-descriptive study was carried out in the Surgical Center Unit of a university hospital aiming to measure time spent with concurrent cleaning performed by the cleaning service and turnover time and also investigated potential associations between cleaning time and the surgery's magnitude and specialty, period of the day and the room's size. The sample consisted of 101 surgeries, computing cleaning time and 60 surgeries, computing turnover time. The Kaplan-Meier method was used to analyze time and Pearson's correlation to study potential correlations. The time spent in concurrent cleaning was 7.1 minutes and turnover time was 35.6 minutes. No association between cleaning time and the other variables was found. These findings can support nurses in the efficient use of resources thereby speeding up the work process in the operating room.

  6. The mean, the median, and the St. Petersburg paradox

    Directory of Open Access Journals (Sweden)

    Benjamin Y. Hayden

    2009-06-01

    Full Text Available The St.~Petersburg Paradox is a famous economic and philosophical puzzle that has generated numerous conflicting explanations. To shed empirical light on this phenomenon, we examined subjects' bids for one St.~Petersburg gamble with a real monetary payment. We found that bids were typically lower than twice the smallest payoff, and thus much lower than is generally supposed. We also examined bids offered for several hypothetical variants of the St.~Petersburg Paradox. We found that bids were weakly affected by truncating the gamble, were strongly affected by repeats of the gamble, and depended linearly on the initial ``seed'' value of the gamble. One explanation, which we call the extit{median} extit{heuristic}, strongly predicts these data. Subjects following this strategy evaluate a gamble as if they were taking the median rather than the mean of the payoff distribution. Finally, we argue that the distribution of outcomes embodied in the St.~Petersburg paradox is so divergent from the Gaussian form that the statistical mean is a poor estimator of expected value, so that the expected value of the St.~Petersburg gamble is undefined. These results suggest that this classic paradox has a straightforward explanation rooted in the use of a statistical heuristic.

  7. "Knife to skin" time is a poor marker of operating room utilization and efficiency in cardiac surgery.

    Science.gov (United States)

    Luthra, Suvitesh; Ramady, Omar; Monge, Mary; Fitzsimons, Michael G; Kaleta, Terry R; Sundt, Thoralf M

    2015-06-01

    Markers of operation room (OR) efficiency in cardiac surgery are focused on "knife to skin" and "start time tardiness." These do not evaluate the middle and later parts of the cardiac surgical pathway. The purpose of this analysis was to evaluate knife to skin time as an efficiency marker in cardiac surgery. We looked at knife to skin time, procedure time, and transfer times in the cardiac operational pathway for their correlation with predefined indices of operational efficiency (Index of Operation Efficiency - InOE, Surgical Index of Operational Efficiency - sInOE). A regression analysis was performed to test the goodness of fit of the regression curves estimated for InOE relative to the times on the operational pathway. The mean knife to skin time was 90.6 ± 13 minutes (23% of total OR time). The mean procedure time was 282 ± 123 minutes (71% of total OR time). Utilization efficiencies were highest for aortic valve replacement and coronary artery bypass grafting and least for complex aortic procedures. There were no significant procedure-specific or team-specific differences for standard procedures. Procedure times correlated the strongest with InOE (r = -0.98, p knife to skin is not as strong an indicator of efficiency. A statistically significant linear dependence on InOE was observed with "procedure times" only. Procedure times are a better marker of OR efficiency than knife to skin in cardiac cases. Strategies to increase OR utilization and efficiency should address procedure times in addition to knife to skin times. © 2015 Wiley Periodicals, Inc.

  8. Tecnatom's operation system interfaces and their evolution in time

    International Nuclear Information System (INIS)

    Trueba, Pedro

    1998-01-01

    The author comments the evolution of operation system interfaces produced by the Tecnatom Company, notably for the support in the construction of the Spanish nuclear power plants. A system can typically be divided into a data acquisition system, a central processing system, and a graphical system. The author discusses and comments the main functional applications which are: real time data displays, data analysis functions, and other utilities (file management, data storing, file reloading)

  9. APPLICATION OF TRAVEL TIME RELIABILITY FOR PERFORMANCE ORIENTED OPERATIONAL PLANNING OF EXPRESSWAYS

    Science.gov (United States)

    Mehran, Babak; Nakamura, Hideki

    Evaluation of impacts of congestion improvement scheme s on travel time reliability is very significant for road authorities since travel time reliability repr esents operational performance of expressway segments. In this paper, a methodology is presented to estimate travel tim e reliability prior to implementation of congestion relief schemes based on travel time variation modeling as a function of demand, capacity, weather conditions and road accident s. For subject expressway segmen ts, traffic conditions are modeled over a whole year considering demand and capacity as random variables. Patterns of demand and capacity are generated for each five minute interval by appl ying Monte-Carlo simulation technique, and accidents are randomly generated based on a model that links acci dent rate to traffic conditions. A whole year analysis is performed by comparing de mand and available capacity for each scenario and queue length is estimated through shockwave analysis for each time in terval. Travel times are estimated from refined speed-flow relationships developed for intercity expressways and buffer time index is estimated consequently as a measure of travel time reliability. For validation, estimated reliability indices are compared with measured values from empirical data, and it is shown that the proposed method is suitable for operational evaluation and planning purposes.

  10. Development and operation of a real-time simulation at the NASA Ames Vertical Motion Simulator

    Science.gov (United States)

    Sweeney, Christopher; Sheppard, Shirin; Chetelat, Monique

    1993-01-01

    The Vertical Motion Simulator (VMS) facility at the NASA Ames Research Center combines the largest vertical motion capability in the world with a flexible real-time operating system allowing research to be conducted quickly and effectively. Due to the diverse nature of the aircraft simulated and the large number of simulations conducted annually, the challenge for the simulation engineer is to develop an accurate real-time simulation in a timely, efficient manner. The SimLab facility and the software tools necessary for an operating simulation will be discussed. Subsequent sections will describe the development process through operation of the simulation; this includes acceptance of the model, validation, integration and production phases.

  11. Mission reliability of semi-Markov systems under generalized operational time requirements

    International Nuclear Information System (INIS)

    Wu, Xiaoyue; Hillston, Jane

    2015-01-01

    Mission reliability of a system depends on specific criteria for mission success. To evaluate the mission reliability of some mission systems that do not need to work normally for the whole mission time, two types of mission reliability for such systems are studied. The first type corresponds to the mission requirement that the system must remain operational continuously for a minimum time within the given mission time interval, while the second corresponds to the mission requirement that the total operational time of the system within the mission time window must be greater than a given value. Based on Markov renewal properties, matrix integral equations are derived for semi-Markov systems. Numerical algorithms and a simulation procedure are provided for both types of mission reliability. Two examples are used for illustration purposes. One is a one-unit repairable Markov system, and the other is a cold standby semi-Markov system consisting of two components. By the proposed approaches, the mission reliability of systems with time redundancy can be more precisely estimated to avoid possible unnecessary redundancy of system resources. - Highlights: • Two types of mission reliability under generalized requirements are defined. • Equations for both types of reliability are derived for semi-Markov systems. • Numerical methods are given for solving both types of reliability. • Simulation procedure is given for estimating both types of reliability. • Verification of the numerical methods is given by the results of simulation

  12. Tokamak power reactor ignition and time dependent fractional power operation

    International Nuclear Information System (INIS)

    Vold, E.L.; Mau, T.K.; Conn, R.W.

    1986-06-01

    A flexible time-dependent and zero-dimensional plasma burn code with radial profiles was developed and employed to study the fractional power operation and the thermal burn control options for an INTOR-sized tokamak reactor. The code includes alpha thermalization and a time-dependent transport loss which can be represented by any one of several currently popular scaling laws for energy confinement time. Ignition parameters were found to vary widely in density-temperature (n-T) space for the range of scaling laws examined. Critical ignition issues were found to include the extent of confinement time degradation by alpha heating, the ratio of ion to electron transport power loss, and effect of auxiliary heating on confinement. Feedback control of the auxiliary power and ion fuel sources are shown to provide thermal stability near the ignition curve

  13. Overcoming misconceptions in quantum mechanics with the time evolution operator

    International Nuclear Information System (INIS)

    Garcia Quijas, P C; Arevalo Aguilar, L M

    2007-01-01

    Recently, there have been many efforts to use the research techniques developed in the field of physics education research to improve the teaching and learning of quantum mechanics. In particular, part of this research is focusing on misconceptions held by students. For instance, a set of misconceptions is associated with the concept of stationary states. In this paper, we argue that a possible way to remove these is to solve the Schroedinger equation using the evolution operator method (EOM), and stress the fact that to find stationary states is only the first step in solving that equation. The EOM consists in solving the Schroedinger equation by direct integration, i.e. Ψ(x, t) = U(t)Ψ(x, 0), where U(t)=e -itH-hat/h is the time evolution operator, and Ψ(x, 0) is the initial state. We apply the evolution operator method in the case of the harmonic oscillator

  14. Sosiaalisen median merkitys mikroyrityksille - Case: TallFits Oy

    OpenAIRE

    Nousiainen, Ari; Koskivuori, Timo

    2011-01-01

    Tämän opinnäytetyön aiheena on sosiaalinen media mikroyritysten näkökulmasta. Työssä käsi-tellään sosiaalista mediaa ja markkinoinnissa tapahtunutta muutosta sekä niitä toimintatapoja, joita interaktiivinen mediaympäristö yrityksille ja sen asiakkaille tarjoaa. Työn tavoitteena on tuottaa tietoa sosiaalisen median hyödyistä ja haasteista mikroyrityksille ja lisätä koh-deyrityksemme TallFits Oy:n myyntiä ja löydettävyyttä. Tavoitteiden saavuttamiseksi opinnäytetyömme tarkoituksena oli tehd...

  15. MOPITT Near Real-Time Data for LANCE: Automatic Quality Assurance and Comparison to Operational Products

    Science.gov (United States)

    Martinez-Alonso, S.; Deeter, M. N.; Worden, H. M.; Ziskin, D.

    2017-12-01

    Terra-MOPITT (the Measurements of Pollution in the Troposphere instrument) near real-time (NRT) carbon monoxide (CO) products have been selected for distribution through NASA's LANCE (the Land, Atmosphere Near Real-Time Capability for EOS). MOPITT version 7 NRT data will be made publicly available within 3 hours from observation. The retrieval process is the same for both MOPITT NRT and operational products, albeit for the former it is constrained to use ancillary data available within the latency time. Among other requirements, LANCE NRT products must be examined for quality assurance (QA) purposes and relative errors between NRT and operational products must be quantified. Here we present an algorithm for automatic MOPITT NRT QA aimed to identify artifacts and separate those from anomalously high but real CO values. The algorithm is based on a comparison to the statistics of MOPITT operational products. We discuss the algorithm's performance when tested by applying it to three MOPITT datasets: a known (and corrected) artifact in version 4 operational data, anomalously high CO values in operational data during the 2015 Indonesia fires, and actual NRT data. Last, we describe results from a quantitative comparison between MOPITT NRT data and their operational counterparts.

  16. Extending an open-source real-time operating system with hierarchical scheduling

    NARCIS (Netherlands)

    Holenderski, M.J.; Cools, W.A.; Bril, R.J.; Lukkien, J.J.

    2010-01-01

    Hierarchical scheduling frameworks (HSFs) have been devised to support the integration of independently developed and analyzed subsystems. This paper presents an efficient, modular and extendible design for enhancing a real-time operating system with periodic tasks, two-level fixed-priority HSF

  17. A time series model: First-order integer-valued autoregressive (INAR(1))

    Science.gov (United States)

    Simarmata, D. M.; Novkaniza, F.; Widyaningsih, Y.

    2017-07-01

    Nonnegative integer-valued time series arises in many applications. A time series model: first-order Integer-valued AutoRegressive (INAR(1)) is constructed by binomial thinning operator to model nonnegative integer-valued time series. INAR (1) depends on one period from the process before. The parameter of the model can be estimated by Conditional Least Squares (CLS). Specification of INAR(1) is following the specification of (AR(1)). Forecasting in INAR(1) uses median or Bayesian forecasting methodology. Median forecasting methodology obtains integer s, which is cumulative density function (CDF) until s, is more than or equal to 0.5. Bayesian forecasting methodology forecasts h-step-ahead of generating the parameter of the model and parameter of innovation term using Adaptive Rejection Metropolis Sampling within Gibbs sampling (ARMS), then finding the least integer s, where CDF until s is more than or equal to u . u is a value taken from the Uniform(0,1) distribution. INAR(1) is applied on pneumonia case in Penjaringan, Jakarta Utara, January 2008 until April 2016 monthly.

  18. On $L^p$ Estimates for the Time-Dependent Schrodinger Operator on $L^2$

    CERN Document Server

    Mortad, M H

    2006-01-01

    Let L denote the time-dependent Schrodinger operator in n space variables. We consider a variety of Lebesgue norms for functions u on R^{n+1}, and prove or disprove estimates for such norms of u in terms of the L^2-norms of u and Lu. The results have implications for self-adjo intness of operators of the form L+V where V is a multiplication operator. The proofs are based mainly on the Strichartz-type inequalities.

  19. Development of a prototype real-time automated filter for operational deep space navigation

    Science.gov (United States)

    Masters, W. C.; Pollmeier, V. M.

    1994-01-01

    Operational deep space navigation has been in the past, and is currently, performed using systems whose architecture requires constant human supervision and intervention. A prototype for a system which allows relatively automated processing of radio metric data received in near real-time from NASA's Deep Space Network (DSN) without any redesign of the existing operational data flow has been developed. This system can allow for more rapid response as well as much reduced staffing to support mission navigation operations.

  20. Operating system for a real-time multiprocessor propulsion system simulator. User's manual

    Science.gov (United States)

    Cole, G. L.

    1985-01-01

    The NASA Lewis Research Center is developing and evaluating experimental hardware and software systems to help meet future needs for real-time, high-fidelity simulations of air-breathing propulsion systems. Specifically, the real-time multiprocessor simulator project focuses on the use of multiple microprocessors to achieve the required computing speed and accuracy at relatively low cost. Operating systems for such hardware configurations are generally not available. A real time multiprocessor operating system (RTMPOS) that supports a variety of multiprocessor configurations was developed at Lewis. With some modification, RTMPOS can also support various microprocessors. RTMPOS, by means of menus and prompts, provides the user with a versatile, user-friendly environment for interactively loading, running, and obtaining results from a multiprocessor-based simulator. The menu functions are described and an example simulation session is included to demonstrate the steps required to go from the simulation loading phase to the execution phase.

  1. AN AMELIORATED DETECTION STATISTICS FOR ADAPTIVE MASK MEDIAN FILTRATION OF HEAVILY NOISED DIGITAL IMAGES

    Directory of Open Access Journals (Sweden)

    Geeta Hanji

    2016-11-01

    Full Text Available Noise reduction is an important area of research in image processing applications. The performance of the digital image noise filtering method primarily depends upon the accuracy of noise detection scheme. This paper presents an effective detector based, adaptive mask, median filtration of heavily noised digital images affected with fixed value (or salt and pepper impulse noise. The proposed filter presents a novel approach; an ameliorated Rank Ordered Absolute Deviation (ROAD statistics to judge whether the input pixel is noised or noise free. If a pixel is detected as corrupted, it is subjected to adaptive mask median filtration; otherwise, it is kept unchanged. Extensive experimental results and comparative performance evaluations demonstrate that the proposed filter outperforms the existing decision type, median based filters with powerful noise detectors in terms of objective performance measures and visual retrieviation accuracy.

  2. Robot-Assisted Thoracoscopic Surgery versus Video-Assisted Thoracoscopic Surgery for Lung Lobectomy: Can a Robotic Approach Improve Short-Term Outcomes and Operative Safety?

    Science.gov (United States)

    Mahieu, Julien; Rinieri, Philippe; Bubenheim, Michael; Calenda, Emile; Melki, Jean; Peillon, Christophe; Baste, Jean-Marc

    2016-06-01

    Background Minimally invasive surgery has been recently recommended for treatment of early-stage non-small cell lung cancer. Despite the recent increase of robotic surgery, the place and potential advantages of the robot in thoracic surgery has not been well defined until now. Methods We reviewed our prospective database for retrospective comparison of our first 28 video-assisted thoracoscopic surgery lobectomies (V group) and our first 28 robotic lobectomies (R group). Results No significant difference was shown in median operative time between the two groups (185 vs. 190 minutes, p = 0.56). Median preincision time was significantly longer in the R group (80 vs. 60 minutes, P < 0.0001). The rate of emergency conversion for uncontrolled bleeding was lower in the R group (one vs. four). Median length of stay was comparable (6 days in the R group vs. 7 days in the V group, p = 0.4) with no significant difference in the rate of postoperative complications (eight Grade I in both groups, four Grade III or IV in the V group vs. six in the R group, according to the Clavien-Dindo classification, p = 0.93). No postoperative cardiac morbidity was observed in the R group. Median drainage time was similar (5 days, p = 0.78), with a rate of prolonged air leak slightly higher in the R group (25 vs. 17.8%, p = 0.74). Conclusion Perioperative outcomes are similar even in the learning period but robotic approach seems to offer more operative safety with fewer conversions for uncontrolled bleeding. Georg Thieme Verlag KG Stuttgart · New York.

  3. Real Time Space Weather Support for Chandra X-Ray Observatory Operations

    Science.gov (United States)

    O'Dell, Stephen L.; Minow, Joseph I.; Miller, J. Scott; Wolk, Scott J.; Aldcroft, Thomas L.; Spitzbart, Bradley D.; Swartz. Douglas A.

    2012-01-01

    NASA launched the Chandra X-ray Observatory in July 1999. Soon after first light in August 1999, however, degradation in the energy resolution and charge transfer efficiency of the Advanced CCD Imaging Spectrometer (ACIS) x-ray detectors was observed. The source of the degradation was quickly identified as radiation damage in the charge-transfer channel of the front-illuminated CCDs, by weakly penetrating ( soft , 100 500 keV) protons as Chandra passed through the Earth s radiation belts and ring currents. As soft protons were not considered a risk to spacecraft health before launch, the only on-board radiation monitoring system is the Electron, Proton, and Helium Instrument (EPHIN) which was included on Chandra with the primary purpose of monitoring energetic solar particle events. Further damage to the ACIS detector has been successfully mitigated through a combination of careful mission planning, autonomous on-board radiation protection, and manual intervention based upon real-time monitoring of the soft-proton environment. The AE-8 and AP-8 trapped radiation models and Chandra Radiation Models are used to schedule science operations in regions of low proton flux. EPHIN has been used as the primary autonomous in-situ radiation trigger; but, it is not sensitive to the soft protons that damage the front-illuminated CCDs. Monitoring of near-real-time space weather data sources provides critical information on the proton environment outside the Earth s magnetosphere due to solar proton events and other phenomena. The operations team uses data from the Geostationary Operational Environmental Satellites (GOES) to provide near-real-time monitoring of the proton environment; however, these data do not give a representative measure of the soft-proton (real-time data provided by NOAA s Space Weather Prediction Center. This presentation describes the radiation mitigation strategies to minimize the proton damage in the ACIS CCD detectors and the importance of real-time data

  4. Post-event human decision errors: operator action tree/time reliability correlation

    International Nuclear Information System (INIS)

    Hall, R.E.; Fragola, J.; Wreathall, J.

    1982-11-01

    This report documents an interim framework for the quantification of the probability of errors of decision on the part of nuclear power plant operators after the initiation of an accident. The framework can easily be incorporated into an event tree/fault tree analysis. The method presented consists of a structure called the operator action tree and a time reliability correlation which assumes the time available for making a decision to be the dominating factor in situations requiring cognitive human response. This limited approach decreases the magnitude and complexity of the decision modeling task. Specifically, in the past, some human performance models have attempted prediction by trying to emulate sequences of human actions, or by identifying and modeling the information processing approach applicable to the task. The model developed here is directed at describing the statistical performance of a representative group of hypothetical individuals responding to generalized situations

  5. Post-event human decision errors: operator action tree/time reliability correlation

    Energy Technology Data Exchange (ETDEWEB)

    Hall, R E; Fragola, J; Wreathall, J

    1982-11-01

    This report documents an interim framework for the quantification of the probability of errors of decision on the part of nuclear power plant operators after the initiation of an accident. The framework can easily be incorporated into an event tree/fault tree analysis. The method presented consists of a structure called the operator action tree and a time reliability correlation which assumes the time available for making a decision to be the dominating factor in situations requiring cognitive human response. This limited approach decreases the magnitude and complexity of the decision modeling task. Specifically, in the past, some human performance models have attempted prediction by trying to emulate sequences of human actions, or by identifying and modeling the information processing approach applicable to the task. The model developed here is directed at describing the statistical performance of a representative group of hypothetical individuals responding to generalized situations.

  6. Gender-partitioned patient medians of serum albumin requested by general practitioners for the assessment of analytical stability.

    Science.gov (United States)

    Hansen, Steen Ingemann; Petersen, Per Hyltoft; Lund, Flemming; Fraser, Callum G; Sölétormos, György

    2018-04-25

    Recently, the use of separate gender-partitioned patient medians of serum sodium has revealed potential for monitoring analytical stability within the optimum analytical performance specifications for laboratory medicine. The serum albumin concentration depends on whether a patient is sitting or recumbent during phlebotomy. We therefore investigated only examinations requested by general practitioners (GPs) to provide data from sitting patients. Weekly and monthly patient medians of serum albumin requested by GP for both male and female patients were calculated from the raw data obtained from three analysers in the hospital laboratory on examination of samples from those >18 years. The half-range of medians were applied as an estimate of the maximum bias. Further, the ratios between the two medians were calculated (females/males). The medians for male and female patients were closely related despite considerable variation due to the current analytical variation. This relationship was confirmed by the calculated half-range for the monthly ratio between the genders of 0.44%, which surpasses the optimum analytical performance specification for bias of serum albumin (0.72%). The weekly ratio had a half-range of 1.83%, which surpasses the minimum analytical performance specifications of 2.15%. Monthly gender-partitioned patient medians of serum albumin are useful for monitoring of long-term analytical stability, where the gender medians are two independent estimates of changes in (delta) bias: only results requested by GP are of value in this application to ensure that all patients are sitting during phlebotomy.

  7. CONTRIBUTIONS TO THE CALCULATION OF NORM TIME EDGE THINNING OPERATIONS PARTS OF FOOTWEAR

    Directory of Open Access Journals (Sweden)

    MALCOCI Marina

    2016-05-01

    Full Text Available It is known that regulations allow the introduction in production regimes efficient operation of equipment and methods of rational organization of production. To ensure accuracy imposed regulations must meet the following conditions: to take into account the main factors influencing consumption of work; depending on the types of production which they are intended to ensure adequate precision. In this work the analysis literature authors proposed a new relationship for calculating the standard time for the operation of thinning also set the value of two coefficients K1 and K2. K1 is a constant coefficient for thinning operation of 1,0549; and K2 - a constant that depends on the degree of automation of the machine. Knowing the degree of mechanization machines and time required to perform operation coefficient was determined K2, namely Km – 1,0833; KM – 1,0460; KA – 0,0785. Since the relationship for the calculation of the time aids not it into consideration that a part may contain from 3 to 5 types of profiles, it has been proposed that it be included in the relationship, so there was obtained a new relationship calculation. The study conducted also allowed the optimization of computing time assistant relationship, including the number of adjustments in relation computing machine. Proper use of normative values, taking into account the type of machine, but also their knowledge calclulul methodology allow us to identify the following positive effects on the company's footwear: reducing workload; achieving balanced labor standards; saving human effort; reducing worker fatigue etc.

  8. Integrated payload and mission planning, phase 3. Volume 3: Ground real-time mission operations

    Science.gov (United States)

    White, W. J.

    1977-01-01

    The payloads tentatively planned to fly on the first two Spacelab missions were analyzed to examine the cost relationships of providing mission operations support from onboard vs the ground-based Payload Operations Control Center (POCC). The quantitative results indicate that use of a POCC, with data processing capability, to support real-time mission operations is the most cost effective case.

  9. Performance analysis and kernel size study of the Lynx real-time operating system

    Science.gov (United States)

    Liu, Yuan-Kwei; Gibson, James S.; Fernquist, Alan R.

    1993-01-01

    This paper analyzes the Lynx real-time operating system (LynxOS), which has been selected as the operating system for the Space Station Freedom Data Management System (DMS). The features of LynxOS are compared to other Unix-based operating system (OS). The tools for measuring the performance of LynxOS, which include a high-speed digital timer/counter board, a device driver program, and an application program, are analyzed. The timings for interrupt response, process creation and deletion, threads, semaphores, shared memory, and signals are measured. The memory size of the DMS Embedded Data Processor (EDP) is limited. Besides, virtual memory is not suitable for real-time applications because page swap timing may not be deterministic. Therefore, the DMS software, including LynxOS, has to fit in the main memory of an EDP. To reduce the LynxOS kernel size, the following steps are taken: analyzing the factors that influence the kernel size; identifying the modules of LynxOS that may not be needed in an EDP; adjusting the system parameters of LynxOS; reconfiguring the device drivers used in the LynxOS; and analyzing the symbol table. The reductions in kernel disk size, kernel memory size and total kernel size reduction from each step mentioned above are listed and analyzed.

  10. Post-operative pain relief using local infiltration analgesia during open abdominal hysterectomy: a randomized, double-blind study.

    Science.gov (United States)

    Hayden, J M; Oras, J; Karlsson, O I; Olausson, K G; Thörn, S-E; Gupta, A

    2017-05-01

    Post-operative pain is common and often severe after open abdominal hysterectomy, and analgesic consumption high. This study assessed the efficacy of local infiltration analgesia (LIA) injected systematically into different tissues during surgery compared with saline on post-operative pain and analgesia. Fifty-nine patients were randomized to Group LIA (n = 29) consisting of 156 ml of a mixture of 0.2% ropivacaine + 30 mg ketorolac + 0.5 mg (5 ml) adrenaline, where the drugs were injected systematically in the operating site, around the proximal vagina, the ligaments, in the fascia and subcutaneously, or to saline and intravenous ketorolac, Group C (Control, n = 28), in a double-blind study. Post-operative pain, analgesic consumption, side-effects, and home discharge were analysed. Median dose of rescue morphine given 0-24 h after surgery was significantly lower in group LIA (18 mg, IQR 5-25 mg) compared with group C (27 mg, IQR 15-43 mg, P = 0.028). Median time to first analgesic injection was significantly longer in group LIA (40 min, IQR 20-60 min) compared with group C (20 min, IQR 12-30 min, P = 0.009). NRS score was lower in the group LIA compared with group C in the direct post-operative period (0-2 h). No differences were found in post-operative side-effects or home discharge between the groups. Systematically injected local infiltration analgesia for pain management was superior to saline in the primary endpoint, resulting in significantly lower rescue morphine requirements during 0-24 h, longer time to first analgesic request and lower early post-operative pain intensity. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  11. Evaluation of real-time operating system for small-scale embedded systems

    International Nuclear Information System (INIS)

    Dayang Norhayati Abang Jawawi; Rosbi Mamat

    1999-01-01

    In this paper, the performance of some real-time operating systems for small-scale embedded systems are evaluated based on some criteria. The evaluation is performed qualitatively and quantitatively. The evaluation results based on a case study on an engineering application will be presented. (author)

  12. Contemporary management of median arcuate ligament syndrome provides early symptom improvement

    Science.gov (United States)

    Columbo, Jesse A.; Trus, Thadeus; Nolan, Brian; Goodney, Philip; Rzucidlo, Eva; Powell, Richard; Walsh, Daniel; Stone, David

    2017-01-01

    Objective Optimal diagnosis and management of median arcuate ligament (MAL) syndrome (MALS) remains unclear in contemporary practice. The advent and evolution of laparoscopic and endovascular techniques has redirected management toward a less invasive therapeutic algorithm. This study examined our contemporary outcomes of patients treated for MALS. Methods All patients treated for MALS at Dartmouth-Hitchcock Medical Center from 2000 to 2013 were retrospectively reviewed. Demographics and comorbidities were recorded. Freedom from symptoms and freedom from reintervention were the primary end points. Return to work or school was assessed. Follow-up by clinic visits and telephone allowed quantitative comparisons among the patients. Results During the study interval, 21 patients (24% male), with a median age of 42 years, were treated for MALS. All patients complained of abdominal pain in the presence of a celiac stenosis, 16 (76%) also reported weight loss at the time of presentation, and 57% had a concomitant psychiatric history. Diagnostic imaging most commonly used included duplex ultrasound (81%), computed tomography angiography (66%), angiography (57%), and magnetic resonance angiography (5%). Fourteen patients (67%) underwent multiple diagnostic studies. All patients underwent initial laparoscopic MAL release. Seven patients (33%) underwent subsequent celiac stent placement in the setting of recurrent or unresolved symptoms with persistent celiac stenosis at a mean interval of 49 days. Two patients required surgical bypass after an endovascular intervention failed. The 6-month freedom from symptoms was 75% and freedom from reintervention was 64%. Eighteen patients (81%) reported early symptom improvement and weight gain, and 66% were able to return to work. Conclusions A multidisciplinary treatment approach using initial laparoscopic release and subsequent stent placement and bypass surgery provides symptom improvement in most patients treated for MALS. The

  13. Improving operating room efficiency in academic children's hospital using Lean Six Sigma methodology.

    Science.gov (United States)

    Tagge, Edward P; Thirumoorthi, Arul S; Lenart, John; Garberoglio, Carlos; Mitchell, Kenneth W

    2017-06-01

    Lean Six Sigma (LSS) is a process improvement methodology that utilizes a collaborative team effort to improve performance by systematically identifying root causes of problems. Our objective was to determine whether application of LSS could improve efficiency when applied simultaneously to all services of an academic children's hospital. In our tertiary academic medical center, a multidisciplinary committee was formed, and the entire perioperative process was mapped, using fishbone diagrams, Pareto analysis, and other process improvement tools. Results for Children's Hospital scheduled main operating room (OR) cases were analyzed, where the surgical attending followed themselves. Six hundred twelve cases were included in the seven Children's Hospital operating rooms (OR) over a 6-month period. Turnover Time (interval between patient OR departure and arrival of the subsequent patient) decreased from a median 41min in the baseline period to 32min in the intervention period (p<0.0001). Turnaround Time (interval between surgical dressing application and subsequent surgical incision) decreased from a median 81.5min in the baseline period to 71min in the intervention period (p<0.0001). These results demonstrate that a coordinated multidisciplinary process improvement redesign can significantly improve efficiency in an academic Children's Hospital without preselecting specific services, removing surgical residents, or incorporating new personnel or technology. Prospective comparative study, Level II. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Understanding Fish Linear Acceleration Using an Undulatory Biorobotic Model with Soft Fluidic Elastomer Actuated Morphing Median Fins.

    Science.gov (United States)

    Wen, Li; Ren, Ziyu; Di Santo, Valentina; Hu, Kainan; Yuan, Tao; Wang, Tianmiao; Lauder, George V

    2018-04-10

    Although linear accelerations are an important common component of the diversity of fish locomotor behaviors, acceleration is one of the least-understood aspects of propulsion. Analysis of acceleration behavior in fishes with both spiny and soft-rayed median fins demonstrates that fin area is actively modulated when fish accelerate. We implemented an undulatory biomimetic robotic fish model with median fins manufactured using multimaterial three-dimensional printing-a spiny-rayed dorsal fin, soft-rayed dorsal/anal fins, and a caudal fin-whose stiffnesses span three orders of magnitude. We used an array of fluidic elastomeric soft actuators to mimic the dorsal/anal inclinator and erector/depressor muscles of fish, which allowed the soft fins to be erected or folded within 0.3 s. We experimentally show that the biomimetic soft dorsal/anal fin can withstand external loading. We found that erecting the soft dorsal/anal fins significantly enhanced the linear acceleration rate, up to 32.5% over the folded fin state. Surprisingly, even though the projected area of the body (in the lateral plane) increased 16.9% when the median fins were erected, the magnitude of the side force oscillation decreased by 24.8%, which may have led to significantly less side-to-side sway in the robotic swimmer. Visualization of fluid flow in the wake of median fins reveals that during linear acceleration, the soft dorsal fin generates a wake flow opposite in direction to that of the caudal fin, which creates propulsive jets with time-variant circulations and jet angles. Erectable/foldable fins provide a new design space for bioinspired underwater robots with structures that morph to adapt to different locomotor behaviors. This biorobotic fish model is also a potentially promising system for studying the dynamics of complex multifin fish swimming behaviors, including linear acceleration, steady swimming, and burst and coast, which are difficult to analyze in freely swimming fishes.

  15. A real-time expert system for nuclear power plant failure diagnosis and operational guide

    International Nuclear Information System (INIS)

    Naito, N.; Sakuma, A.; Shigeno, K.; Mori, N.

    1987-01-01

    A real-time expert system (DIAREX) has been developed to diagnose plant failure and to offer a corrective operational guide for boiling water reactor (BWR) power plants. The failure diagnosis model used in DIAREX was systematically developed, based mainly on deep knowledge, to cover heuristics. Complex paradigms for knowledge representation were adopted, i.e., the process representation language and the failure propagation tree. The system is composed of a knowledge base, knowledge base editor, preprocessor, diagnosis processor, and display processor. The DIAREX simulation test has been carried out for many transient scenarios, including multiple failures, using a real-time full-scope simulator modeled after the 1100-MW(electric) BWR power plant. Test results showed that DIAREX was capable of diagnosing a plant failure quickly and of providing a corrective operational guide with a response time fast enough to offer valuable information to plant operators

  16. NOAA's Strategy to Improve Operational Weather Prediction Outlooks at Subseasonal Time Range

    Science.gov (United States)

    Schneider, T.; Toepfer, F.; Stajner, I.; DeWitt, D.

    2017-12-01

    NOAA is planning to extend operational global numerical weather prediction to sub-seasonal time range under the auspices of its Next Generation Global Prediction System (NGGPS) and Extended Range Outlook Programs. A unification of numerical prediction capabilities for weather and subseasonal to seasonal (S2S) timescales is underway at NOAA using the Finite Volume Cubed Sphere (FV3) dynamical core as the basis for the emerging unified system. This presentation will overview NOAA's strategic planning and current activities to improve prediction at S2S time-scales that are ongoing in response to the Weather Research and Forecasting Innovation Act of 2017, Section 201. Over the short-term, NOAA seeks to improve the operational capability through improvements to its ensemble forecast system to extend its range to 30 days using the new FV3 Global Forecast System model, and by using this system to provide reforecast and re-analyses. In parallel, work is ongoing to improve NOAA's operational product suite for 30 day outlooks for temperature, precipitation and extreme weather phenomena.

  17. EOS: A project to investigate the design and construction of real-time distributed Embedded Operating Systems

    Science.gov (United States)

    Campbell, R. H.; Essick, Ray B.; Johnston, Gary; Kenny, Kevin; Russo, Vince

    1987-01-01

    Project EOS is studying the problems of building adaptable real-time embedded operating systems for the scientific missions of NASA. Choices (A Class Hierarchical Open Interface for Custom Embedded Systems) is an operating system designed and built by Project EOS to address the following specific issues: the software architecture for adaptable embedded parallel operating systems, the achievement of high-performance and real-time operation, the simplification of interprocess communications, the isolation of operating system mechanisms from one another, and the separation of mechanisms from policy decisions. Choices is written in C++ and runs on a ten processor Encore Multimax. The system is intended for use in constructing specialized computer applications and research on advanced operating system features including fault tolerance and parallelism.

  18. Kajian dan Implementasi Real Time Operating System pada Single Board Computer Berbasis Arm

    Directory of Open Access Journals (Sweden)

    Wiedjaja A

    2014-06-01

    Full Text Available Operating System is an important software in computer system. For personal and office use the operating system is sufficient. However, to critical mission applications such as nuclear power plants and braking system on the car (auto braking system which need a high level of reliability, it requires operating system which operates in real time. The study aims to assess the implementation of the Linux-based operating system on a Single Board Computer (SBC ARM-based, namely Pandaboard ES with the Dual-core ARM Cortex-A9, TI OMAP 4460 type. Research was conducted by the method of implementation of the General Purpose OS Ubuntu 12:04 OMAP4-armhf-RTOS and Linux 3.4.0-rt17 + on PandaBoard ES. Then research compared the latency value of each OS on no-load and with full-load condition. The results obtained show the maximum latency value of RTOS on full load condition is at 45 uS, much smaller than the maximum value of GPOS at full-load at 17.712 uS. The lower value of latency demontrates that the RTOS has ability to run the process in a certain period of time much better than the GPOS.

  19. Development of a subway operation incident delay model using accelerated failure time approaches.

    Science.gov (United States)

    Weng, Jinxian; Zheng, Yang; Yan, Xuedong; Meng, Qiang

    2014-12-01

    This study aims to develop a subway operational incident delay model using the parametric accelerated time failure (AFT) approach. Six parametric AFT models including the log-logistic, lognormal and Weibull models, with fixed and random parameters are built based on the Hong Kong subway operation incident data from 2005 to 2012, respectively. In addition, the Weibull model with gamma heterogeneity is also considered to compare the model performance. The goodness-of-fit test results show that the log-logistic AFT model with random parameters is most suitable for estimating the subway incident delay. First, the results show that a longer subway operation incident delay is highly correlated with the following factors: power cable failure, signal cable failure, turnout communication disruption and crashes involving a casualty. Vehicle failure makes the least impact on the increment of subway operation incident delay. According to these results, several possible measures, such as the use of short-distance and wireless communication technology (e.g., Wifi and Zigbee) are suggested to shorten the delay caused by subway operation incidents. Finally, the temporal transferability test results show that the developed log-logistic AFT model with random parameters is stable over time. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Assessment of operative times of multiple surgical specialties in a public university hospital.

    Science.gov (United States)

    Costa, Altair da Silva

    2017-01-01

    To evaluate the indicators duration of anesthesia, operative time and time patients stay in the operating rooms of different surgical specialties at a public university hospital. It was done by a descriptive cross-sectional study based on the operating room database. The following stages were measured: duration of anesthesia, procedure time and patient length of stay in the room of the various specialties. We included surgeries carried out in sequence in the same room, between 7:00 a.m. and 5 p.m., either elective or emergency. We calculated the 80th percentile of the stages, where 80% of procedures were below this value. The study measured 8,337 operations of 12 surgical specialties performed within one year. The overall mean duration of anesthesia of all specialties was 178.12±110.46 minutes, and the 80th percentile was 252 minutes. The mean operative time was 130.45±97.23 minutes, and the 80th percentile was 195 minutes. The mean total time of the patient in the operating room was 197.30±113.71 minutes, and the 80th percentile was 285 minutes. Thus, the variation of the overall mean compared to the 80th percentile was 41% for anesthesia, 49% for surgeries and 44% for operating room time. In average, anesthesia took up 88% of the operating room period, and surgery, 61%. This study identified patterns in the duration of surgery stages. The mean values of the specialties can assist with operating room planning and reduce delays. Avaliar os indicadores de tempo da anestesia, da operação e da permanência do paciente em sala de diversas especialidades do centro cirúrgico de um hospital universitário. Foi realizado em estudo descritivo transversal a partir da base de dados do centro cirúrgico e mensuradas as seguintes etapas: duração de anestesia, tempo do procedimento e tempo de permanência do paciente em sala das diversas especialidades. Foram incluídas as operações realizadas em sequência na mesma sala, das 7h às 17h, eletivas ou de urg

  1. [Use of four kinds of three-dimensional printing guide plate in bone tumor resection and reconstruction operation].

    Science.gov (United States)

    Fu, Jun; Guo, Zheng; Wang, Zhen; Li, Xiangdong; Fan, Hongbin; Li, Jing; Pei, Yanjun; Pei, Guoxian; Li, Dan

    2014-03-01

    To explore the effectiveness of excision and reconstruction of bone tumor by using operation guide plate made by variety of three-dimensional (3-D) printing techniques, and to compare the advantages and disadvantages of different 3-D printing techniques in the manufacture and application of operation guide plate. Between September 2012 and January 2014, 31 patients with bone tumor underwent excision and reconstruction of bone tumor by using operation guide plate. There were 19 males and 12 females, aged 6-67 years (median, 23 years). The disease duration ranged from 15 days to 12 months (median, 2 months). There were 13 cases of malignant tumor and 18 cases of benign tumor. The tumor located in the femur (9 cases), the spine (7 cases), the tibia (6 cases), the pelvis (5 cases), the humerus (3 cases), and the fibula (1 case). Four kinds of 3-D printing technique were used in processing operation guide plate: fused deposition modeling (FDM) in 9 cases, stereo lithography appearance (SLA) in 14 cases, 3-D printing technique in 5 cases, and selective laser sintering (SLS) in 3 cases; the materials included ABS resin, photosensitive resin, plaster, and aluminum alloy, respectively. Before operation, all patients underwent thin layer CT scanning (0.625 mm) in addition to conventional imaging. The data were collected for tumor resection design, and operation guide plate was designed on the basis of excision plan. Preoperatively, the operation guide plates were made by 3-D printing equipment. After sterilization, the guide plates were used for excision and reconstruction of bone tumor. The time of plates processing cycle was recorded to analyse the efficiency of 4 kinds of 3-D printing techniques. The time for design and operation and intraoperative fluoroscopy frequency were recorded. Twenty-eight patients underwent similar operations during the same period as the control group. The processing time of operation guide plate was (19.3 +/- 6.5) hours in FDM, (5.2 +/- 1

  2. Accuracy of Perceived Estimated Travel Time by EMS to a Trauma Center in San Bernardino County, California

    Directory of Open Access Journals (Sweden)

    Michael M. Neeki

    2016-06-01

    Full Text Available Introduction: Mobilization of trauma resources has the potential to cause ripple effects throughout hospital operations. One major factor affecting efficient utilization of trauma resources is a discrepancy between the prehospital estimated time of arrival (ETA as communicated by emergency medical services (EMS personnel and their actual time of arrival (TOA. The current study aimed to assess the accuracy of the perceived prehospital estimated arrival time by EMS personnel in comparison to their actual arrival time at a Level II trauma center in San Bernardino County, California. Methods: This retrospective study included traumas classified as alerts or activations that were transported to Arrowhead Regional Medical Center in 2013. We obtained estimated arrival time and actual arrival time for each transport from the Surgery Department Trauma Registry. The difference between the median of ETA and actual TOA by EMS crews to the trauma center was calculated for these transports. Additional variables assessed included time of day and month during which the transport took place. Results: A total of 2,454 patients classified as traumas were identified in the Surgery Department Trauma Registry. After exclusion of trauma consults, walk-ins, handoffs between agencies, downgraded traumas, traumas missing information, and traumas transported by agencies other than American Medical Response, Ontario Fire, Rialto Fire or San Bernardino County Fire, we included a final sample size of 555 alert and activation classified traumas in the final analysis. When combining all transports by the included EMS agencies, the median of the ETA was 10 minutes and the median of the actual TOA was 22 minutes (median of difference=9 minutes, p<0.0001. Furthermore, when comparing the difference between trauma alerts and activations, trauma activations demonstrated an equal or larger difference in the median of the estimated and actual time of arrival (p<0.0001. We also found

  3. Hybrid (laparoscopy + stent treatment of celiac trunk compression syndrome (Dunbar syndrome, median arcuate ligament syndrome (MALS

    Directory of Open Access Journals (Sweden)

    Maciej Michalik

    2016-12-01

    Full Text Available Introduction : Celiac trunk (CT compression syndrome caused by the median arcuate ligament (MAL is a rarely diagnosed disease because of its nonspecific symptoms, which cause a delay in the correct diagnosis. Intestinal ischemia occurs, which causes symptoms of abdominal angina. One method of treatment for this disease is surgical release of the CT – the intersection of the MAL. Laparoscopy is the first step of the hybrid technique combined with percutaneous angioplasty and stenting of the CT. Aim: To demonstrate the usefulness and advantages of the laparoscopic approach in the treatment of Dunbar syndrome. Material and methods : Between 2013 and 2016 in the General and Minimally Invasive Surgery Department of the Medical Sciences Faculty of the University of Warmia and Mazury in Olsztyn, 6 laparoscopic procedures were performed because of median arcuate ligament syndrome. During the laparoscopy the MAL was cut with a harmonic scalpel. One month after laparoscopy 5 patients had Doppler percutaneous angioplasty of the CT with stent implantation in the Vascular Surgery Department in Pomeranian Medical University in Szczecin. Results : In one case, there was a conversion of laparoscopic surgery to open due to unmanageable intraoperative bleeding. In one case, postoperative ultrasound examination of the abdominal cavity demonstrated the presence of a large hematoma in the retroperitoneal space. All patients reported relief of symptoms in the first days after the operation. Conclusions : The hybrid method, combining laparoscopy and angioplasty, seems to be a long-term solution, which increases the comfort of the patient, brings the opportunity for normal functioning and minimizes the risk of restenosis.

  4. Hybrid (laparoscopy + stent) treatment of celiac trunk compression syndrome (Dunbar syndrome, median arcuate ligament syndrome (MALS)).

    Science.gov (United States)

    Michalik, Maciej; Dowgiałło-Wnukiewicz, Natalia; Lech, Paweł; Majda, Kaja; Gutowski, Piotr

    2016-01-01

    Celiac trunk (CT) compression syndrome caused by the median arcuate ligament (MAL) is a rarely diagnosed disease because of its nonspecific symptoms, which cause a delay in the correct diagnosis. Intestinal ischemia occurs, which causes symptoms of abdominal angina. One method of treatment for this disease is surgical release of the CT - the intersection of the MAL. Laparoscopy is the first step of the hybrid technique combined with percutaneous angioplasty and stenting of the CT. To demonstrate the usefulness and advantages of the laparoscopic approach in the treatment of Dunbar syndrome. Between 2013 and 2016 in the General and Minimally Invasive Surgery Department of the Medical Sciences Faculty of the University of Warmia and Mazury in Olsztyn, 6 laparoscopic procedures were performed because of median arcuate ligament syndrome. During the laparoscopy the MAL was cut with a harmonic scalpel. One month after laparoscopy 5 patients had Doppler percutaneous angioplasty of the CT with stent implantation in the Vascular Surgery Department in Pomeranian Medical University in Szczecin. In one case, there was a conversion of laparoscopic surgery to open due to unmanageable intraoperative bleeding. In one case, postoperative ultrasound examination of the abdominal cavity demonstrated the presence of a large hematoma in the retroperitoneal space. All patients reported relief of symptoms in the first days after the operation. The hybrid method, combining laparoscopy and angioplasty, seems to be a long-term solution, which increases the comfort of the patient, brings the opportunity for normal functioning and minimizes the risk of restenosis.

  5. Imageless navigation total hip arthroplasty – an evaluation of operative time

    Directory of Open Access Journals (Sweden)

    Valsamis Epaminondas Markos

    2018-01-01

    Discussion: This is the first study that demonstrates no added operative time when using imageless navigation in THA, achieved with an improved workflow. The results also demonstrate a very reasonable learning curve.

  6. Platelet-rich plasma limits the nerve injury caused by 10% dextrose in the rabbit median nerve.

    Science.gov (United States)

    Park, Gi-Young; Kwon, Dong Rak

    2014-01-01

    We evaluated the effect of platelet-rich plasma (PRP) injection in a rabbit model of dextrose-induced median nerve injury. New Zealand white rabbits (n = 15) were divided randomly into 3 groups. Three different regimens (group 1: 0.1 ml saline; group 2: 10% dextrose with PRP; group 3: 10% dextrose with saline) were injected within the carpal tunnel. Electrophysiological and histological findings were evaluated 12 weeks after the injection. The mean median motor latency in group 3 was significantly longer than that in groups 1 and 2. The cross-sectional area of the median nerve and subsynovial connective tissue thickness in group 3 were significantly larger than those in groups 1 and 2. PRP injection may be effective in controlling median nerve injury, as demonstrated by improvement in electrophysiological and histological findings 12 weeks after dextrose injection. Copyright © 2013 Wiley Periodicals, Inc.

  7. Dynamic state estimation and prediction for real-time control and operation

    NARCIS (Netherlands)

    Nguyen, P.H.; Venayagamoorthy, G.K.; Kling, W.L.; Ribeiro, P.F.

    2013-01-01

    Real-time control and operation are crucial to deal with increasing complexity of modern power systems. To effectively enable those functions, it is required a Dynamic State Estimation (DSE) function to provide accurate network state variables at the right moment and predict their trends ahead. This

  8. Impact of operative time on early joint infection and deep vein thrombosis in primary total hip arthroplasty.

    Science.gov (United States)

    Wills, B W; Sheppard, E D; Smith, W R; Staggers, J R; Li, P; Shah, A; Lee, S R; Naranje, S M

    2018-03-22

    Infections and deep vein thrombosis (DVT) after total hip arthroplasty (THA) are challenging problems for both the patient and surgeon. Previous studies have identified numerous risk factors for infections and DVT after THA but have often been limited by sample size. We aimed to evaluate the effect of operative time on early postoperative infection as well as DVT rates following THA. We hypothesized that an increase in operative time would result in increased odds of acquiring an infection as well as a DVT. We conducted a retrospective analysis of prospectively collected data using the American College of Surgeons National Surgical Quality Improvement Program (NSQIP) database from 2006 to 2015 for all patients undergoing primary THA. Associations between operative time and infection or DVT were evaluated with multivariable logistic regressions controlling for demographics and several known risks factors for infection. Three different types of infections were evaluated: (1) superficial surgical site infection (SSI), an infection involving the skin or subcutaneous tissue, (2) deep SSI, an infection involving the muscle or fascial layers beneath the subcutaneous tissue, and (3) organ/space infection, an infection involving any part of the anatomy manipulated during surgery other than the incisional components. In total, 103,044 patients who underwent THA were included in our study. Our results suggested a significant association between superficial SSIs and operative time. Specifically, the adjusted odds of suffering a superficial SSI increased by 6% (CI=1.04-1.08, ptime. When using dichotomized operative time (90minutes), the adjusted odds of suffering a superficial SSI was 56% higher for patients with prolonged operative time (CI=1.05-2.32, p=0.0277). The adjusted odds of suffering a deep SSI increased by 7% for every 10-minute increase in operative time (CI=1.01-1.14, p=0.0335). No significant associations were detected between organ/space infection, wound

  9. Investigation of the Adaptability of Transient Stability Assessment Methods to Real-Time Operation

    DEFF Research Database (Denmark)

    Weckesser, Johannes Tilman Gabriel; Jóhannsson, Hjörtur; Sommer, Stefan

    2012-01-01

    In this paper, an investigation of the adaptability of available transient stability assessment methods to real-time operation and their real-time performance is carried out. Two approaches based on Lyapunov’s method and the equal area criterion are analyzed. The results allow to determine...

  10. Filtering with the Centered Moving Median to Effectively Monitor Solution Processes for Safeguard Purposes

    Energy Technology Data Exchange (ETDEWEB)

    Richir, Patrice; Dzbikowicz, Zdzislaw [Institute for Transuranium Elements (ITU), Joint Research Centre (JRC), European Commission, Ispra, Varese (Italy)

    2012-06-15

    Reprocessing plants require continuous and integrated safeguards activities by inspectors of the IAEA and Euratom because of their proliferation-sensitivity as complex facilities handling large quantities of direct use nuclear material. In support of both organizations, the JRC has developed a solution monitoring software package (DAI, Data Analysis and Interpretation) which has been implemented in the main commercial European reprocessing plants and which allows enhanced monitoring of nuclear materials in the processed solutions. This tool treats data acquired from different sensor types (e.g. from pressure transducers monitoring the solution levels in tanks). Collected signals are often noisy because of the instrumentation itself and/or because of ambient and operational conditions (e.g. pumps, ventilation systems or electromagnetic interferences) and therefore require filtering. Filtering means reduction of information and has to be applied correctly to avoid misinterpretation of the process steps. This paper describes the study of some filters one of which is the centered moving median which has been revealed as a powerful tool for solution monitoring.

  11. Radiographic signs of open median sternotomy in neonates and infants

    Energy Technology Data Exchange (ETDEWEB)

    Wu, George [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Geisinger Medical Center, Danville, PA (United States); Jaimes, Camilo; Markowitz, Richard I. [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Gaynor, J.W. [The Children' s Hospital of Philadelphia, Department of Surgery, Philadelphia, PA (United States)

    2012-06-15

    Leaving the median sternotomy wound open following cardiac surgery is employed to avoid cardiovascular compression. Horizontal struts can be used. Radiologists interpreting portable radiographs might be unaware of the open median sternotomy (OMS). To describe the frequency of radiographic signs of OMS and to increase awareness among radiologists to prevent misdiagnosis of pneumothorax and pneumomediastinum. Radiographs of 41 infants (17 girls/24 boys) with OMS were studied (age range 2 days to 8 months, mean 33 days). Central lucency and sternal edges were noted. Interclavicular distances before and after sternotomy were compared. Central lucency was seen in 25/41 (61%) children. Sternal struts were apparent in 27 (66%). In 14 without struts, central lucency was present in 8 (57%). In 27 children with struts, central lucency was present in 17 (63%) and absent in 10 (37%). Split sternal centers were identified in 6/41 (15%). The mean interclavicular distance was 23.5 mm (SD = 4.39) before sternotomy and 38.2 mm (SD = 7.0 mm) after sternotomy (P < 0.001). OMS has characteristic signs in the majority of cases. Recognition of these findings is useful and can prevent misinterpretation. (orig.)

  12. Median Modified Wiener Filter for nonlinear adaptive spatial denoising of protein NMR multidimensional spectra

    KAUST Repository

    Cannistraci, Carlo Vittorio

    2015-01-26

    Denoising multidimensional NMR-spectra is a fundamental step in NMR protein structure determination. The state-of-the-art method uses wavelet-denoising, which may suffer when applied to non-stationary signals affected by Gaussian-white-noise mixed with strong impulsive artifacts, like those in multi-dimensional NMR-spectra. Regrettably, Wavelet\\'s performance depends on a combinatorial search of wavelet shapes and parameters; and multi-dimensional extension of wavelet-denoising is highly non-trivial, which hampers its application to multidimensional NMR-spectra. Here, we endorse a diverse philosophy of denoising NMR-spectra: less is more! We consider spatial filters that have only one parameter to tune: the window-size. We propose, for the first time, the 3D extension of the median-modified-Wiener-filter (MMWF), an adaptive variant of the median-filter, and also its novel variation named MMWF*. We test the proposed filters and the Wiener-filter, an adaptive variant of the mean-filter, on a benchmark set that contains 16 two-dimensional and three-dimensional NMR-spectra extracted from eight proteins. Our results demonstrate that the adaptive spatial filters significantly outperform their non-adaptive versions. The performance of the new MMWF* on 2D/3D-spectra is even better than wavelet-denoising. Noticeably, MMWF* produces stable high performance almost invariant for diverse window-size settings: this signifies a consistent advantage in the implementation of automatic pipelines for protein NMR-spectra analysis.

  13. Median Modified Wiener Filter for nonlinear adaptive spatial denoising of protein NMR multidimensional spectra

    KAUST Repository

    Cannistraci, Carlo Vittorio; Abbas, Ahmed; Gao, Xin

    2015-01-01

    Denoising multidimensional NMR-spectra is a fundamental step in NMR protein structure determination. The state-of-the-art method uses wavelet-denoising, which may suffer when applied to non-stationary signals affected by Gaussian-white-noise mixed with strong impulsive artifacts, like those in multi-dimensional NMR-spectra. Regrettably, Wavelet's performance depends on a combinatorial search of wavelet shapes and parameters; and multi-dimensional extension of wavelet-denoising is highly non-trivial, which hampers its application to multidimensional NMR-spectra. Here, we endorse a diverse philosophy of denoising NMR-spectra: less is more! We consider spatial filters that have only one parameter to tune: the window-size. We propose, for the first time, the 3D extension of the median-modified-Wiener-filter (MMWF), an adaptive variant of the median-filter, and also its novel variation named MMWF*. We test the proposed filters and the Wiener-filter, an adaptive variant of the mean-filter, on a benchmark set that contains 16 two-dimensional and three-dimensional NMR-spectra extracted from eight proteins. Our results demonstrate that the adaptive spatial filters significantly outperform their non-adaptive versions. The performance of the new MMWF* on 2D/3D-spectra is even better than wavelet-denoising. Noticeably, MMWF* produces stable high performance almost invariant for diverse window-size settings: this signifies a consistent advantage in the implementation of automatic pipelines for protein NMR-spectra analysis.

  14. Regional gastrointestinal transit times in severe ulcerative colitis.

    Science.gov (United States)

    Haase, A M; Gregersen, T; Christensen, L A; Agnholt, J; Dahlerup, J F; Schlageter, V; Krogh, K

    2016-02-01

    Gastrointestinal (GI) dysmotility may present secondary to inflammatory bowel disease. The main aim of this study was to investigate GI motility in ulcerative colitis (UC) patients during severe disease activity. Twenty patients with severe UC were studied with a novel telemetric capsule system (3D-Transit) designed for minimally invasive, ambulatory assessment of total and regional GI transit times. Ten patients were available for follow-up during remission. Data were compared to those of 20 healthy subjects (HS). Total GI transit time was significantly longer in patients with severe UC (median 44.5 h [range 9.9-102.7 h]) than in HS (median 27.6 h [range 9.6-56.4 h]) (p = 0.032). Additionally, during severe UC, transit time was prolonged through the proximal colon (p = 0.003) and there were strong trends toward longer than normal small intestinal transit time (HS: median 4.9 h [range 3.4-8.3 h] vs severe UC patients: median 5.9 h [range 3.9-11.9 h]; p = 0.053) and colorectal transit times (HS: median 18.2 h [range 1.5-43.7] vs severe UC patients: median 34.9 h [range 0.4-90.9 h]; p = 0.056). Our data further indicate that total GI and colorectal transit times may be prolonged in UC during early remission. Total GI transit times are significantly prolonged during severe UC. © 2016 John Wiley & Sons Ltd.

  15. Calculation of statistic estimates of kinetic parameters from substrate uncompetitive inhibition equation using the median method

    Directory of Open Access Journals (Sweden)

    Pedro L. Valencia

    2017-04-01

    Full Text Available We provide initial rate data from enzymatic reaction experiments and tis processing to estimate the kinetic parameters from the substrate uncompetitive inhibition equation using the median method published by Eisenthal and Cornish-Bowden (Cornish-Bowden and Eisenthal, 1974; Eisenthal and Cornish-Bowden, 1974. The method was denominated the direct linear plot and consists in the calculation of the median from a dataset of kinetic parameters Vmax and Km from the Michaelis–Menten equation. In this opportunity we present the procedure to applicate the direct linear plot to the substrate uncompetitive inhibition equation; a three-parameter equation. The median method is characterized for its robustness and its insensibility to outlier. The calculations are presented in an Excel datasheet and a computational algorithm was developed in the free software Python. The kinetic parameters of the substrate uncompetitive inhibition equation Vmax, Km and Ks were calculated using three experimental points from the dataset formed by 13 experimental points. All the 286 combinations were calculated. The dataset of kinetic parameters resulting from this combinatorial was used to calculate the median which corresponds to the statistic estimator of the real kinetic parameters. A comparative statistical analyses between the median method and the least squares was published in Valencia et al. [3].

  16. An Efficient Randomized Algorithm for Real-Time Process Scheduling in PicOS Operating System

    Science.gov (United States)

    Helmy*, Tarek; Fatai, Anifowose; Sallam, El-Sayed

    PicOS is an event-driven operating environment designed for use with embedded networked sensors. More specifically, it is designed to support the concurrency in intensive operations required by networked sensors with minimal hardware requirements. Existing process scheduling algorithms of PicOS; a commercial tiny, low-footprint, real-time operating system; have their associated drawbacks. An efficient, alternative algorithm, based on a randomized selection policy, has been proposed, demonstrated, confirmed for efficiency and fairness, on the average, and has been recommended for implementation in PicOS. Simulations were carried out and performance measures such as Average Waiting Time (AWT) and Average Turn-around Time (ATT) were used to assess the efficiency of the proposed randomized version over the existing ones. The results prove that Randomized algorithm is the best and most attractive for implementation in PicOS, since it is most fair and has the least AWT and ATT on average over the other non-preemptive scheduling algorithms implemented in this paper.

  17. Determination of operation time function for activimeters; Determinacao da funcao tempo de operacao para ativimetros

    Energy Technology Data Exchange (ETDEWEB)

    Sousa, C.H.S.; Peixoto, J.G.P. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Araujo, G.; Padilha, L.G. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil)

    2016-07-01

    Radiation detectors must pass periodically recommended quality control tests and standardized to certify the quality of measurements, however, many studies have shown that several parameters can influence the results, however, some instrument components that can not be adjusted during calibrations may have significant importance in measurement results over the operating time. This study sought to determine the influence of the use of time in the activity measurements. The results show a trend of decreased activity measured for equipment with detectors with more operating time. (author)

  18. Median artery of the forearm in human fetuses in northeastern Brazil: anatomical study and review of the literature.

    Science.gov (United States)

    Aragão, José Aderval; da Silva, Ana Caroline Ferreira; Anunciação, Caio Barretto; Reis, Francisco Prado

    2017-01-01

    A persistent median artery is a rare anomaly. It accompanies the median nerve along its course in the forearm and is of variable origin. It is associated with other local anatomical variations and may contribute significantly towards formation of the superficial palmar arch. In embryos, it is responsible mainly for the blood supply to the hand. The objective of this study was to research the frequency, type (forearm or palmar) and origin of the median artery in fetuses, correlating its presence with sex and body side. Red-colored latex was injected into 32 brachial arteries of human fetuses until its arrival in the hand could be seen. Twenty-four hours after the injection, the median arteries were dissected without the aid of optical instruments. Among the 32 forearms dissected, the median artery was present in 81.25 % (26) of the cases, and it was found more frequently in females and on the left side. Regarding origin, most of the median arteries originated in the common interosseous artery (38.5 %) and anterior interosseous artery (34.6 %). The mean length of the median arteries was 21.1 mm for the palmar type and 19.8 mm for the forearm type. The median artery has a high rate of persistence. It is important to be aware of this anatomical variation, since its presence may give rise to difficulties during routine surgical procedures on the wrist. Its presence may cause serious functional complications in the carpal tunnel, anterior interosseous nerve, round pronator syndromes, and ischemia of the hand.

  19. Time trends in prostate cancer surgery: data from an Internet-based multicentre database.

    Science.gov (United States)

    Schostak, Martin; Baumunk, Daniel; Jagota, Anita; Klopf, Christian; Winter, Alexander; Schäfers, Sebastian; Kössler, Robert; Brennecke, Volker; Fischer, Tom; Hagel, Susanne; Höchel, Steffen; Jäkel, Dierk; Lehsnau, Mike; Krege, Susanne; Rüffert, Bernd; Pretzer, Jana; Becht, Eduard; Zegenhagen, Thomas; Miller, Kurt; Weikert, Steffen

    2012-02-01

    To report our experience with an Internet-based multicentre database that enables tumour documentation, as well as the collection of quality-related parameters and follow-up data, in surgically treated patients with prostate cancer. The system was used to assess the quality of prostate cancer surgery and to analyze possible time-dependent trends in the quality of care. An Internet-based database system enabled a standardized collection of treatment data and clinical findings from the participating urological centres for the years 2005-2009. An analysis was performed aiming to evaluate relevant patient characteristics (age, pathological tumour stage, preoperative International Index of Erectile Function-5 score), intra-operative parameters (operating time, percentage of nerve-sparing operations, complication rate, transfusion rate, number of resected lymph nodes) and postoperative parameters (hospitalization time, re-operation rate, catheter indwelling time). Mean values were calculated and compared for each annual cohort from 2005 to 2008. The overall survival rate was also calculated for a subgroup of the Berlin patients. A total of 914, 1120, 1434 and 1750 patients submitted to radical prostatectomy in 2005, 2006, 2007 and 2008 were documented in the database. The mean age at the time of surgery remained constant (66 years) during the study period. More than half the patients already had erectile dysfunction before surgery (median International Index of Erectile Function-5 score of 19-20). During the observation period, there was a decrease in the percentage of pT2 tumours (1% in 2005; 64% in 2008) and a slight increase in the percentage of patients with lymph node metastases (8% in 2005; 10% in 2008). No time trend was found for the operating time (142-155 min) or the percentage of nerve-sparing operations (72-78% in patients without erectile dysfunction). A decreasing frequency was observed for the parameters: blood transfusions (1.9% in 2005; 0.5% in 2008

  20. Salvage concurrent radio-chemotherapy for post-operative local recurrence of squamous-cell esophageal cancer

    Directory of Open Access Journals (Sweden)

    Zhang Jian

    2012-06-01

    Full Text Available Abstract Purpose To evaluate the treatment outcome of salvage concurrent radio-chemotherapy for patients with loco-recurrent esophageal cancer after surgery. Methods 50 patients with loco-recurrent squamous-cell cancer after curative esophagectomy were retrospectively analyzed. Patients were treated with radiotherapy (median 60 Gy combined with chemotherapy consisting of either 5-fluorouracil (5-FU plus cisplatin (DDP (R-FP group or paclitaxel plus DDP (R-TP group. Results The median follow-up period was 16.0 months. The 1-year and 3-year survival rates were 56% and 14%, respectively. The median progression-free survival (PFS and overall survival (OS time was 9.8 and 13.3 months respectively. There was no statistical significance of the PFS of the two groups. The OS (median 16.3 months in the R-TP group was superior to that in the R-FP group (median: 9.8 months (p = 0.012. Among the patients who had received ≥60 Gy irradiation dose, the median PFS (10.6 months and OS (16.3 months were significantly superior to the PFS (8.7 months and OS (11.3 months among those patients did not (all p  Conclusions For those patients with post-operative loco-recurrent squamous-cell esophageal carcinoma, radiotherapy combined with either FP or TP regimen chemotherapy was an effective salvage treatment. Younger age, treatment with the TP regimen and an irradiation dose ≥60 Gy might improve the patients’ treatment outcome.

  1. Property Mix Heterogeneity and Market Cycles: How Much Can We Rely on Median-Price Indices?

    Directory of Open Access Journals (Sweden)

    Odilon Ricardo da Hora Gonçalves Fernandes Costa

    2017-05-01

    Full Text Available Objective. Understand in which types of location median-price indices could provide reasonable estimates of rent growth. As far as our research allows, the market-based measures developed througout this study are the first to emphasize office properties in Brazil using an hedonic framework.Methodology. Create appraisal-based indices of rent growth using median-price and hedonic-based techniques for two regions with different degrees of property mix heterogeneity and compare their behavior overtime.Findings. Volatility in median-price measures is larger than hedonic-based measures in market peaks and throughs due to different weighting of high and low-tier properties overtime. This result is stronger in the location with higher property mix heterogeneity and, consequently, exacerbates market cycles in this region.  Limitations. We do not find statistically significant differences between the measures considered. Nevertheless, we do not consider whether this similarity would hold when using transactional-based data.    Value. Our results suggest that researchers, policy makers and investors need to take into account the “undesired fluctuation” of median-price measures when interpreting such indices.  

  2. Some haltuun : Murrosikäisen sosiaalisen median käytön ohjaus terveydenhoitajan työssä

    OpenAIRE

    Paavola, Pinja; Haapala, Lotta

    2016-01-01

    Opinnäytetyön tavoitteena oli lisätä terveydenhoitajien tietämystä sosiaalisesta mediasta, jotta he osaavat ohjata murrosikäisiä sosiaalisen median turvallisessa käytössä ja, että murrosikäinen voi käyttää sosiaalista mediaa turvallisesti. Tarkoituksena oli selvittää, miten murrosikäinen käyttää sosiaalisen median sovelluksia ja miten terveydenhoitaja voisi ohjata sosiaalisen median turvalliseen käyttöön. Tutkimuskysymyksinä oli selvittää; mitä murrosikäinen tietää sosiaalisen median turvalli...

  3. The "p"-Median Model as a Tool for Clustering Psychological Data

    Science.gov (United States)

    Kohn, Hans-Friedrich; Steinley, Douglas; Brusco, Michael J.

    2010-01-01

    The "p"-median clustering model represents a combinatorial approach to partition data sets into disjoint, nonhierarchical groups. Object classes are constructed around "exemplars", that is, manifest objects in the data set, with the remaining instances assigned to their closest cluster centers. Effective, state-of-the-art implementations of…

  4. Resuscitation therapy for traumatic brain injury-induced coma in rats: mechanisms of median nerve electrical stimulation

    Directory of Open Access Journals (Sweden)

    Zhen Feng

    2015-01-01

    Full Text Available In this study, rats were put into traumatic brain injury-induced coma and treated with median nerve electrical stimulation. We explored the wake-promoting effect, and possible mechanisms, of median nerve electrical stimulation. Electrical stimulation upregulated the expression levels of orexin-A and its receptor OX1R in the rat prefrontal cortex. Orexin-A expression gradually increased with increasing stimulation, while OX1R expression reached a peak at 12 hours and then decreased. In addition, after the OX1R antagonist, SB334867, was injected into the brain of rats after traumatic brain injury, fewer rats were restored to consciousness, and orexin-A and OXIR expression in the prefrontal cortex was downregulated. Our findings indicate that median nerve electrical stimulation induced an up-regulation of orexin-A and OX1R expression in the prefrontal cortex of traumatic brain injury-induced coma rats, which may be a potential mechanism involved in the wake-promoting effects of median nerve electrical stimulation.

  5. Hospital markup and operation outcomes in the United States.

    Science.gov (United States)

    Gani, Faiz; Ejaz, Aslam; Makary, Martin A; Pawlik, Timothy M

    2016-07-01

    Although the price hospitals charge for operations has broad financial implications, hospital pricing is not subject to regulation. We sought to characterize national variation in hospital price markup for major cardiothoracic and gastrointestinal operations and to evaluate perioperative outcomes of hospitals relative to hospital price markup. All hospitals in which a patient underwent a cardiothoracic or gastrointestinal procedure were identified using the Nationwide Inpatient Sample for 2012. Markup ratios (ratio of charges to costs) for the total cost of hospitalization were compared across hospitals. Risk-adjusted morbidity, failure-to-rescue, and mortality were calculated using multivariable, hierarchical logistic regression. Among the 3,498 hospitals identified, markup ratios ranged from 0.5-12.2, with a median markup ratio of 2.8 (interquartile range 2.7-3.9). For the 888 hospitals with extreme markup (greatest markup ratio quartile: markup ratio >3.9), the median markup ratio was 4.9 (interquartile range 4.3-6.0), with 10% of these hospitals billing more than 7 times the Medicare-allowable costs (markup ratio ≥7.25). Extreme markup hospitals were more often large (46.3% vs 33.8%, P markup ratio compared with 19.3% (n = 452) and 6.8% (n = 35) of nonprofit and government hospitals, respectively. Perioperative morbidity (32.7% vs 26.4%, P markup hospitals. There is wide variation in hospital markup for cardiothoracic and gastrointestinal procedures, with approximately a quarter of hospital charges being 4 times greater than the actual cost of hospitalization. Hospitals with an extreme markup had greater perioperative morbidity. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. PENERAPAN METODE LEAST MEDIAN SQUARE-MINIMUM COVARIANCE DETERMINANT (LMS-MCD DALAM REGRESI KOMPONEN UTAMA

    Directory of Open Access Journals (Sweden)

    I PUTU EKA IRAWAN

    2013-11-01

    Full Text Available Principal Component Regression is a method to overcome multicollinearity techniques by combining principal component analysis with regression analysis. The calculation of classical principal component analysis is based on the regular covariance matrix. The covariance matrix is optimal if the data originated from a multivariate normal distribution, but is very sensitive to the presence of outliers. Alternatives are used to overcome this problem the method of Least Median Square-Minimum Covariance Determinant (LMS-MCD. The purpose of this research is to conduct a comparison between Principal Component Regression (RKU and Method of Least Median Square - Minimum Covariance Determinant (LMS-MCD in dealing with outliers. In this study, Method of Least Median Square - Minimum Covariance Determinant (LMS-MCD has a bias and mean square error (MSE is smaller than the parameter RKU. Based on the difference of parameter estimators, still have a test that has a difference of parameter estimators method LMS-MCD greater than RKU method.

  7. Second RPA dynamics at finite temperature: time-evolutions of dynamical operators

    International Nuclear Information System (INIS)

    Jang, S.

    1989-01-01

    Time-evolutions of dynamical operators, in particular the generalized density matrix comprising both diagonal and off-diagonal elements, are investigated within the framework of second RPA dynamics at finite temperature. The calculation of the density matrix previously carried out through the appliance of the second RPA master equation by retaining only the slowly oscillating coupling terms is extended to include in the interaction Hamiltonian both the rapidly and slowly oscillating coupling terms. The extended second RPA master equation, thereby formulated without making use of the so-called resonant approximation, is analytically solved and a closed expression for the generalized density matrix is extracted. We provide illustrative examples of the generalized density matrix for various specific initial conditions. We turn particularly our attention to the Poisson distribution type of initial condition for which we deduce specifically a particular form of the density matrix from the solution of the Fokker-Planck equation for the coherent state representation. The relation of the Fokker-Planck equation to the second RPA master equation and its properties are briefly discussed. The oversight incurred in the time-evolution of operators by the resonant approximation is elucidated. The first and second moments of collective coordinates are also computed in relation to the expectation value of various dynamical operators involved in the extended master equation

  8. Deep structure of Porcupine Basin and nature of the Porcupine Median Ridge from seismic refraction tomography

    Science.gov (United States)

    Watremez, L.; Chen, C.; Prada, M.; Minshull, T. A.; O'Reilly, B.; Reston, T. J.; Wagner, G.; Gaw, V.; Klaeschen, D.; Shannon, P.

    2015-12-01

    The Porcupine Basin is a narrow V-shaped failed rifted basin located offshore SW Ireland. It is of Permo-Triassic to Cenozoic age, with the main rifting phase in the Late Jurassic to Early Cretaceous. Porcupine Basin is a key study area to learn about the processes of continental extension and to understand the thermal history of this rifted basin. Previous studies show increasing stretching factors, from less than 1.5 to the North to more than 6 to the South. A ridge feature, the Porcupine Median Ridge, has been identified in the middle of the southernmost part of the basin. During the last three decades, this ridge has been successively interpreted as a volcanic structure, a diapir of partially serpentinized mantle, or a block of continental crust. Its nature still remains debated today. In this study, we use arrival times from refractions and wide-angle reflections in the sedimentary, crustal and mantle layers to image the crustal structure of the thinnest part of the basin, the geometry of the continental thinning from margin to margin, and the Porcupine Median Ridge. The final velocity model is then compared with coincident seismic reflection data. We show that (1) the basin is asymmetric, (2) P-wave velocities in the uppermost mantle are lower than expected for unaltered peridotites, implying upper-mantle serpentinisation, (3) the nature of Porcupine Median Ridge is probably volcanic, and (4) the amount of thinning is greater than shown in previous studies. We discuss the thermal implications of these results for the evolution of this rift system and the processes leading to the formation of failed rifts. This project is funded by the Irish Shelf Petroleum Studies Group (ISPSG) of the Irish Petroleum Infrastructure Programme Group 4.

  9. Median Urinary Iodine Concentrations Are Indicative of Adequate Iodine Status among Women of Reproductive Age in Prey Veng, Cambodia.

    Science.gov (United States)

    Karakochuk, Crystal D; Michaux, Kristina D; Chai, Tze L; Chan, Benny B; Whitfield, Kyly C; Barr, Susan I; McLean, Judy; Talukder, Aminuzzaman; Hou, Kroeun; Ly, Sokhoing; Green, Tim J

    2016-03-03

    Iodine deficiency disorders are estimated to affect over 1.9 million people worldwide. Iodine deficiency is especially serious for women during pregnancy and lactation because of the negative consequences for both mother and infant. The aim of this cross-sectional study was to determine the median urinary iodine concentration (UIC) as a population-level indicator of iodine status among rural women farmers of reproductive age (18-45 years) in the province of Prey Veng, Cambodia. A total of 450 women provided a spot morning urine sample in 2012. Of those women, 93% (n = 420) were non-pregnant and 7% (n = 30) were pregnant at the time of collection. UIC was quantified using the Sandell-Kolthoff reaction with modifications. The median UIC of non-pregnant (139 μg/L) and pregnant women (157 μg/L) were indicative of adequate iodine status using the WHO/UNICEF/ICCIDD epidemiological criteria for both groups (median UIC between 100-199 and 150-249 μg/L, respectively). We conclude that non-pregnant and pregnant women in rural Prey Veng, Cambodia had adequate iodine status based on single spot morning urine samples collected in 2012. More research is warranted to investigate iodine status among larger and more representative populations of women in Cambodia, especially in light of recent policy changes to the national program for universal salt iodization.

  10. Usability testing of wireless broadband LAN in the MEDIAN user trials

    NARCIS (Netherlands)

    Dam, C. van; Vliet, P.J. van; Schuurman, K.; Maltha, S.R.; Leyten, A.J.M.; Dirks, M.W.S.

    1999-01-01

    The main objective of the ACTS MEDIAN project is to build a high speed WCPN/LAN demonstrator system for multimedia applications and demonstrate it in user trials. The demonstrator system, consisting of one base station and two portable stations, is capable of handling high speed (up to 150 Mbit/s)

  11. Predicting in-hospital mortality after redo cardiac operations: development of a preoperative scorecard.

    Science.gov (United States)

    Launcelott, Sebastian; Ouzounian, Maral; Buth, Karen J; Légaré, Jean-Francois

    2012-09-01

    The present study generated a risk model and an easy-to-use scorecard for the preoperative prediction of in-hospital mortality for patients undergoing redo cardiac operations. All patients who underwent redo cardiac operations in which the initial and subsequent procedures were performed through a median sternotomy were included. A logistic regression model was created to identify independent preoperative predictors of in-hospital mortality. The results were then used to create a scorecard predicting operative risk. A total of 1,521 patients underwent redo procedures between 1995 and 2010 at a single institution. Coronary bypass procedures were the most common previous (58%) or planned operations (54%). The unadjusted in-hospital mortality for all redo cases was higher than for first-time procedures (9.7% vs. 3.4%; pscorecard was generated using these independent predictors, stratifying patients undergoing redo cardiac operations into 6 risk categories of in-hospital mortality ranging from risk to >40%. Reoperation represents a significant proportion of modern cardiac surgical procedures and is often associated with significantly higher mortality than first-time operations. We created an easy-to-use scorecard to assist clinicians in estimating operative mortality to ensure optimal decision making in the care of patients facing redo cardiac operations. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Technology strategy for integrated operations and real time reservoir management; Technology Target Areas; TTA5 - Integrated operations and RTRM

    Energy Technology Data Exchange (ETDEWEB)

    2007-07-01

    In Norway Integrated Operations (IO) is a concept which in the first phase (G1) has been used to describe how to integrate processes and people onshore and offshore using ICT solutions and facilities that improve onshore's ability to support offshore operationally. The second generation (G2) Integrated Operations aims to help operators utilize vendors' core competencies and services more efficiently. Utilizing digital services and vendor products, operators will be able to update reservoir models, drilling targets and well trajectories as wells are drilled, manage well completions remotely, optimize production from reservoir to export lines, and implement condition-based maintenance concepts. The total impact on production, recovery rates, costs and safety will be profound. When the international petroleum business moves to the Arctic region the setting is very different from what is the case on the Norwegian Continental Shelf (NCS) and new challenges will arise. The Norwegian Ministry of Environment has recently issued an Integrated Management Plan for the Barents Sea where one focus is on 'Monitoring of the Marine Environment in the North'. The Government aims to establish a new and more coordinated system for monitoring the marine ecosystems in the north. A representative group consisting of the major Operators, the Service Industry, Academia and the Authorities have developed the enclosed strategy for the OG21 Integrated Operations and Real Time Reservoir Management (IO and RTRM) Technology Target Area (TTA). Major technology and work process research and development gaps have been identified in several areas: Bandwidth down-hole to surface; Sensor development including Nano-technology; Cross discipline use of Visualisation, Simulation and model development particularly in Drilling and Reservoir management areas; Software development in terms of data handling, model updating and calculation speed; Enabling reliable and robust communications particularly for

  13. Technology strategy for integrated operations and real time reservoir management; Technology Target Areas; TTA5 - Integrated operations and RTRM

    Energy Technology Data Exchange (ETDEWEB)

    2007-07-01

    In Norway Integrated Operations (IO) is a concept which in the first phase (G1) has been used to describe how to integrate processes and people onshore and offshore using ICT solutions and facilities that improve onshore's ability to support offshore operationally. The second generation (G2) Integrated Operations aims to help operators utilize vendors' core competencies and services more efficiently. Utilizing digital services and vendor products, operators will be able to update reservoir models, drilling targets and well trajectories as wells are drilled, manage well completions remotely, optimize production from reservoir to export lines, and implement condition-based maintenance concepts. The total impact on production, recovery rates, costs and safety will be profound. When the international petroleum business moves to the Arctic region the setting is very different from what is the case on the Norwegian Continental Shelf (NCS) and new challenges will arise. The Norwegian Ministry of Environment has recently issued an Integrated Management Plan for the Barents Sea where one focus is on 'Monitoring of the Marine Environment in the North'. The Government aims to establish a new and more coordinated system for monitoring the marine ecosystems in the north. A representative group consisting of the major Operators, the Service Industry, Academia and the Authorities have developed the enclosed strategy for the OG21 Integrated Operations and Real Time Reservoir Management (IO and RTRM) Technology Target Area (TTA). Major technology and work process research and development gaps have been identified in several areas: Bandwidth down-hole to surface; Sensor development including Nano-technology; Cross discipline use of Visualisation, Simulation and model development particularly in Drilling and Reservoir management areas; Software development in terms of data handling, model updating and calculation speed; Enabling reliable and robust communications

  14. Robust Mediation Analysis Based on Median Regression

    Science.gov (United States)

    Yuan, Ying; MacKinnon, David P.

    2014-01-01

    Mediation analysis has many applications in psychology and the social sciences. The most prevalent methods typically assume that the error distribution is normal and homoscedastic. However, this assumption may rarely be met in practice, which can affect the validity of the mediation analysis. To address this problem, we propose robust mediation analysis based on median regression. Our approach is robust to various departures from the assumption of homoscedasticity and normality, including heavy-tailed, skewed, contaminated, and heteroscedastic distributions. Simulation studies show that under these circumstances, the proposed method is more efficient and powerful than standard mediation analysis. We further extend the proposed robust method to multilevel mediation analysis, and demonstrate through simulation studies that the new approach outperforms the standard multilevel mediation analysis. We illustrate the proposed method using data from a program designed to increase reemployment and enhance mental health of job seekers. PMID:24079925

  15. Reengineering observatory operations for the time domain

    Science.gov (United States)

    Seaman, Robert L.; Vestrand, W. T.; Hessman, Frederic V.

    2014-07-01

    Observatories are complex scientific and technical institutions serving diverse users and purposes. Their telescopes, instruments, software, and human resources engage in interwoven workflows over a broad range of timescales. These workflows have been tuned to be responsive to concepts of observatory operations that were applicable when various assets were commissioned, years or decades in the past. The astronomical community is entering an era of rapid change increasingly characterized by large time domain surveys, robotic telescopes and automated infrastructures, and - most significantly - of operating modes and scientific consortia that span our individual facilities, joining them into complex network entities. Observatories must adapt and numerous initiatives are in progress that focus on redesigning individual components out of the astronomical toolkit. New instrumentation is both more capable and more complex than ever, and even simple instruments may have powerful observation scripting capabilities. Remote and queue observing modes are now widespread. Data archives are becoming ubiquitous. Virtual observatory standards and protocols and astroinformatics data-mining techniques layered on these are areas of active development. Indeed, new large-aperture ground-based telescopes may be as expensive as space missions and have similarly formal project management processes and large data management requirements. This piecewise approach is not enough. Whatever challenges of funding or politics facing the national and international astronomical communities it will be more efficient - scientifically as well as in the usual figures of merit of cost, schedule, performance, and risks - to explicitly address the systems engineering of the astronomical community as a whole.

  16. The upgrade of KSTAR timing system to support long-pulse operation and high-speed data acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Park, Mikyung, E-mail: mkpark@nfri.re.kr [National Fusion Research Institute (NFRI), Daejeon (Korea, Republic of); Lee, Woongryol; Na, Hoonkyun [National Fusion Research Institute (NFRI), Daejeon (Korea, Republic of)

    2012-12-15

    Since the first campaign of KSTAR in 2008, the home-made timing system had run for the synchronized operation of tokamak. The timing board which featured PMC-form factor, giga-bit optical communication, home-made protocol, multi-triggering capability, using GPS time and being integrated to EPICS (Experimental Physics and Industrial Control System), had advantages of compactness, modularity, platform independency and full functionality for the synchronized tokamak operation. However, there was deficiency in timing accuracy resulting from the engagement of software in realization of timing function and timing jitter due to poor isolation in output ports. Moreover, new requirements were on the rise as the plasma pulse length was getting longer and diagnostics operating at the higher frequency were newly installed. In order to meet new requirements and overcome the problems, the new timing board has been developed. As a result, the performance is remarkably enhanced: timing accuracy less than 5 ns, jitter less than 100 ps, 8 configurable multi-triggering sections, provision of maximum 100 MHz sampling clock. The KSTAR timing system upgraded by introducing the new timing board is participating in the 2011 campaign after calibration and consolidating the established timing system. This paper describes design, development and commissioning results of the new KSTAR timing system.

  17. New design for photonic temporal integration with combined high processing speed and long operation time window.

    Science.gov (United States)

    Asghari, Mohammad H; Park, Yongwoo; Azaña, José

    2011-01-17

    We propose and experimentally prove a novel design for implementing photonic temporal integrators simultaneously offering a high processing bandwidth and a long operation time window, namely a large time-bandwidth product. The proposed scheme is based on concatenating in series a time-limited ultrafast photonic temporal integrator, e.g. implemented using a fiber Bragg grating (FBG), with a discrete-time (bandwidth limited) optical integrator, e.g. implemented using an optical resonant cavity. This design combines the advantages of these two previously demonstrated photonic integrator solutions, providing a processing speed as high as that of the time-limited ultrafast integrator and an operation time window fixed by the discrete-time integrator. Proof-of-concept experiments are reported using a uniform fiber Bragg grating (as the original time-limited integrator) connected in series with a bulk-optics coherent interferometers' system (as a passive 4-points discrete-time photonic temporal integrator). Using this setup, we demonstrate accurate temporal integration of complex-field optical signals with time-features as fast as ~6 ps, only limited by the processing bandwidth of the FBG integrator, over time durations as long as ~200 ps, which represents a 4-fold improvement over the operation time window (~50 ps) of the original FBG integrator.

  18. The Bloch wave operator: generalizations and applications: Part I. The time-independent case

    CERN Document Server

    Killingbeck, J P

    2003-01-01

    This is part 1 of a two-part review on wave operator theory and methods. The basic theory of the time-independent wave operator is presented in terms of partitioned matrix theory for the benefit of general readers, with a discussion of the links between the matrix and projection operator approaches. The matrix approach is shown to lead to simple derivations of the wave operators and effective Hamiltonians of Loewdin, Bloch, Des Cloizeaux and Kato as well as to some associated variational forms. The principal approach used throughout stresses the solution of the nonlinear equation for the reduced wave operator, leading to the construction of the effective Hamiltonians of Bloch and of Des Cloizeaux. Several mathematical techniques which are useful in implementing this approach are explained, some of them being relatively little known in the area of wave operator calculations. The theoretical discussion is accompanied by several specimen numerical calculations which apply the described techniques to a selection ...

  19. Change in working characteristics of the steam turbine metal with operating time of more than 330000 hours

    Science.gov (United States)

    Gladshteyn, V. I.; Troitskiy, A. I.

    2017-01-01

    Research of a metal of the stop valve case (SVC) of the K-300-23.5 LMZ turbine (steel grade 15Kh1M1FL), destroyed after operation for 331000 hours, is performed. It's chemical composition and properties are determined as follows: a short-term mechanical tensile stress at 20°C and at elevated temperature, critical temperature, fragility, critical crack opening at elevated temperature, and long-term strength. Furthermore, nature of the microstructure, packing density of carbide particles and their size, and chemical composition of carbide sediment are estimated. A manifestation of metal properties for the main case components by comparison with a forecast of the respective characteristics made for the operating time of 331000 hours is tested. Property-time relationships are built for the forecast using statistical treatment of the test results for the samples cut out from more than 300 parts. Representativeness of the research results is proved: the statistical treatment of their differences are within the range of ±5%. It has been found that, after 150000 hours of operation, only the tensile strength insignificantly depends on the operating time at 20°C, whereas indicators of strength at elevated temperature significantly reduce, depending on the operating time. A brittle-to-ductile transition temperature (BDTT) raises, a critical notch opening changes in a complicated way, a long-term strength reduces. It has been found empirically that the limit of a long-term strength of the SVC metal at 540°C and the operating time of 105 hours is almost 1.6 times less than the required value in the as-delivered state. It is possible to evaluate a service life of the operating valves with the operating time of more than 330000 hours with respect to the long-term strength of the metal taking into account the actual temperature and stress. Guidelines for the control of similar parts are provided.

  20. A Concurrent Implementation of the Cascade-Correlation Algorithm, Using the Time Warp Operating System

    Science.gov (United States)

    Springer, P.

    1993-01-01

    This paper discusses the method in which the Cascade-Correlation algorithm was parallelized in such a way that it could be run using the Time Warp Operating System (TWOS). TWOS is a special purpose operating system designed to run parellel discrete event simulations with maximum efficiency on parallel or distributed computers.

  1. The median hazard ratio: a useful measure of variance and general contextual effects in multilevel survival analysis.

    Science.gov (United States)

    Austin, Peter C; Wagner, Philippe; Merlo, Juan

    2017-03-15

    Multilevel data occurs frequently in many research areas like health services research and epidemiology. A suitable way to analyze such data is through the use of multilevel regression models (MLRM). MLRM incorporate cluster-specific random effects which allow one to partition the total individual variance into between-cluster variation and between-individual variation. Statistically, MLRM account for the dependency of the data within clusters and provide correct estimates of uncertainty around regression coefficients. Substantively, the magnitude of the effect of clustering provides a measure of the General Contextual Effect (GCE). When outcomes are binary, the GCE can also be quantified by measures of heterogeneity like the Median Odds Ratio (MOR) calculated from a multilevel logistic regression model. Time-to-event outcomes within a multilevel structure occur commonly in epidemiological and medical research. However, the Median Hazard Ratio (MHR) that corresponds to the MOR in multilevel (i.e., 'frailty') Cox proportional hazards regression is rarely used. Analogously to the MOR, the MHR is the median relative change in the hazard of the occurrence of the outcome when comparing identical subjects from two randomly selected different clusters that are ordered by risk. We illustrate the application and interpretation of the MHR in a case study analyzing the hazard of mortality in patients hospitalized for acute myocardial infarction at hospitals in Ontario, Canada. We provide R code for computing the MHR. The MHR is a useful and intuitive measure for expressing cluster heterogeneity in the outcome and, thereby, estimating general contextual effects in multilevel survival analysis. © 2016 The Authors. Statistics in Medicine published by John Wiley & Sons Ltd. © 2016 The Authors. Statistics in Medicine published by John Wiley & Sons Ltd.

  2. The influence of tourniquet use and operative time on the incidence of deep vein thrombosis in total knee arthroplasty.

    Science.gov (United States)

    Hernandez, Arnaldo José; Almeida, Adriano Marques de; Fávaro, Edmar; Sguizzato, Guilherme Turola

    2012-09-01

    To evaluate the association between tourniquet and total operative time during total knee arthroplasty and the occurrence of deep vein thrombosis. Seventy-eight consecutive patients from our institution underwent cemented total knee arthroplasty for degenerative knee disorders. The pneumatic tourniquet time and total operative time were recorded in minutes. Four categories were established for total tourniquet time: 120 minutes. Three categories were defined for operative time: 150 minutes. Between 7 and 12 days after surgery, the patients underwent ascending venography to evaluate the presence of distal or proximal deep vein thrombosis. We evaluated the association between the tourniquet time and total operative time and the occurrence of deep vein thrombosis after total knee arthroplasty. In total, 33 cases (42.3%) were positive for deep vein thrombosis; 13 (16.7%) cases involved the proximal type. We found no statistically significant difference in tourniquet time or operative time between patients with or without deep vein thrombosis. We did observe a higher frequency of proximal deep vein thrombosis in patients who underwent surgery lasting longer than 120 minutes. The mean total operative time was also higher in patients with proximal deep vein thrombosis. The tourniquet time did not significantly differ in these patients. We concluded that surgery lasting longer than 120 minutes increases the risk of proximal deep vein thrombosis.

  3. Improved operative efficiency using a real-time MRI-guided stereotactic platform for laser amygdalohippocampotomy.

    Science.gov (United States)

    Ho, Allen L; Sussman, Eric S; Pendharkar, Arjun V; Le, Scheherazade; Mantovani, Alessandra; Keebaugh, Alaine C; Drover, David R; Grant, Gerald A; Wintermark, Max; Halpern, Casey H

    2018-04-01

    OBJECTIVE MR-guided laser interstitial thermal therapy (MRgLITT) is a minimally invasive method for thermal destruction of benign or malignant tissue that has been used for selective amygdalohippocampal ablation for the treatment of temporal lobe epilepsy. The authors report their initial experience adopting a real-time MRI-guided stereotactic platform that allows for completion of the entire procedure in the MRI suite. METHODS Between October 2014 and May 2016, 17 patients with mesial temporal sclerosis were selected by a multidisciplinary epilepsy board to undergo a selective amygdalohippocampal ablation for temporal lobe epilepsy using MRgLITT. The first 9 patients underwent standard laser ablation in 2 phases (operating room [OR] and MRI suite), whereas the next 8 patients underwent laser ablation entirely in the MRI suite with the ClearPoint platform. A checklist specific to the real-time MRI-guided laser amydalohippocampal ablation was developed and used for each case. For both cohorts, clinical and operative information, including average case times and accuracy data, was collected and analyzed. RESULTS There was a learning curve associated with using this real-time MRI-guided system. However, operative times decreased in a linear fashion, as did total anesthesia time. In fact, the total mean patient procedure time was less in the MRI cohort (362.8 ± 86.6 minutes) than in the OR cohort (456.9 ± 80.7 minutes). The mean anesthesia time was significantly shorter in the MRI cohort (327.2 ± 79.9 minutes) than in the OR cohort (435.8 ± 78.4 minutes, p = 0.02). CONCLUSIONS The real-time MRI platform for MRgLITT can be adopted in an expedient manner. Completion of MRgLITT entirely in the MRI suite may lead to significant advantages in procedural times.

  4. Angiotensin converting enzyme 1 in the median preoptic nucleus contributes to chronic intermittent hypoxia hypertension.

    Science.gov (United States)

    Faulk, Katelynn E; Nedungadi, T Prashant; Cunningham, J Thomas

    2017-05-01

    Obstructive sleep apnea is associated with hypertension and cardiovascular disease. Chronic intermittent hypoxia is used to model the arterial hypoxemia seen in sleep apnea patients and is associated with increased sympathetic nerve activity and a sustained diurnal increase in blood pressure. The renin angiotensin system has been associated with hypertension seen in chronic intermittent hypoxia. Angiotensin converting enzyme 1, which cleaves angiotensin I to the active counterpart angiotensin II, is present within the central nervous system and has been shown to be regulated by AP-1 transcription factors, such as ΔFosB. Our previous study suggested that this transcriptional regulation in the median preoptic nucleus contributes to the sustained blood pressure seen following chronic intermittent hypoxia. Viral mediated delivery of a short hairpin RNA against angiotensin converting enzyme 1 in the median preoptic nucleus was used along with radio-telemetry measurements of blood pressure to test this hypothesis. FosB immunohistochemistry was utilized in order to assess the effects of angiotensin converting enzyme 1 knockdown on the activity of nuclei downstream from median preoptic nucleus. Angiotensin converting enzyme 1 knockdown within median preoptic nucleus significantly attenuated the sustained hypertension seen in chronic intermittent hypoxia. Angiotensin converting enzyme 1 seems to be partly responsible for regulating downstream regions involved in sympathetic and blood pressure control, such as the paraventricular nucleus and the rostral ventrolateral medulla. The data suggest that angiotensin converting enzyme 1 within median preoptic nucleus plays a critical role in the sustained hypertension seen in chronic intermittent hypoxia. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  5. Obesity Increases Operative Time in Children Undergoing Laparoscopic Cholecystectomy.

    Science.gov (United States)

    Pandian, T K; Ubl, Daniel S; Habermann, Elizabeth B; Moir, Christopher R; Ishitani, Michael B

    2017-03-01

    Few studies have assessed the impact of obesity on laparoscopic cholecystectomy (LC) in pediatric patients. Children who underwent LC were identified from the 2012 to 2013 American College of Surgeons' National Surgical Quality Improvement Program Pediatrics data. Patient characteristics, operative details, and outcomes were compared. Multivariable logistic regression was utilized to identify predictors of increased operative time (OT) and duration of anesthesia (DOAn). In total, 1757 patients were identified. Due to low rates of obesity in children obese). Among obese children, 80.6% were girls. A higher proportion of obese patients had diabetes (3.0% versus 1.0%, P obesity was an independent predictor of OT >90 (odds ratio [OR] 2.02; 95% confidence interval [95% CI] 1.55-2.63), and DOAn >140 minutes (OR 1.86; 95% CI 1.42-2.43). Obesity is an independent risk factor for increased OT in children undergoing LC. Pediatric surgeons and anesthesiologists should be prepared for the technical and physiological challenges that obesity may pose in this patient population.

  6. Experience of thymectomy by median sternotomy in patients with myasthenia gravis

    International Nuclear Information System (INIS)

    Hussain, N.; Ahmed, S.W.; Ahmed, T.; Hafeez, A.B.; Baloch, R.; Ali, S.

    2010-01-01

    Objective: To determine the outcome of thymectomy in patients with myasthenia gravis and safety of median sternotomy approach. Methodology: An observational descriptive study was conducted in the department of thoracic surgery JPMC from February 2005 to January 2009. Twenty two patients having persistent generalized or ocular myasthenia gravis referred to our department by neurologists and general physicians, partially or not responding to medical treatment with or without thymoma, were included in the study. Those who were not fit for anaesthesia were excluded. Preoperatively 2 to 3 sessions of plasmaphaeresis were done and each patient was given anti myasthenia gravis treatment. Clinical staging was done by Modified Osserman classification. Median sternotomy approach was used. Outcome was assessed on the basis of remission of disease in different Osserman groups. All patients were followed for a minimum of 6 months. Results: Out of 22 patients, 16 (72.7%) were females and 6 (27.2%) males. Mean age at presentation was 35.2 +- 14.5 years. Mean duration of symptoms was 1.5 +- 1.2 years. A total of 4 (18.1%) patients with myasthenia gravis had thymoma and histopathology of 18 (81.9%) patients showed thymic hyperplasia. Remission was seen in most grades of Osserman. The best response was seen in Grade I where all patients achieved remission. Most patients in Grade II A and II B were benefited. The only patient in Grade III had no improvement of symptoms. No patient in Grade IV underwent thymectomy. Overall 86.3 % had a positive outcome on basis of remission and improvement. Conclusion: Thymectomy by median sternotomy is safe and effective with more favourable outcomes for patients of myasthenia gravis not responding to medical treatment. (author)

  7. Implications of Perioperative Team Setups for Operating Room Management Decisions.

    Science.gov (United States)

    Doll, Dietrich; Kauf, Peter; Wieferich, Katharina; Schiffer, Ralf; Luedi, Markus M

    2017-01-01

    Team performance has been studied extensively in the perioperative setting, but the managerial impact of interprofessional team performance remains unclear. We hypothesized that the interplay between anesthesiologists and surgeons would affect operating room turnaround times, and teams that worked together over time would become more efficient. We analyzed 13,632 surgical cases at our hospital that involved 64 surgeons and 48 anesthesiologists. We detrended and adjusted the data for potential confounders including age, American Society of Anesthesiologists physical status, and surgical list (scheduled cases of specific surgical specialties). The surgical lists were categorized as ear, nose, and throat surgery; trauma surgery; general surgery; and gynecology. We assessed the relationship between turnaround times and assignment of different anesthesiologists to specific surgeons using a Monte Carlo simulation. We found significant differences in team performances among the different surgical lists but no team learning. We constructed managerial decision tables for the assignment of anesthesiologists to specific surgeons at our hospital. We defined a decision algorithm based on these tables. Our analysis indicated that had this algorithm been used in staffing the operating room for the surgical cases represented in our data, median turnaround times would have a reduction potential of 6.8% (95% confidence interval 6.3% to 7.1%). A surgeon is usually predefined for scheduled surgeries (surgical list). Allocation of the right anesthesiologist to a list and to a surgeon can affect the team performance; thus, this assignment has managerial implications regarding the operating room efficiency affecting turnaround times and thus potentially overutilized time of a list at our hospital.

  8. The Perforation-Operation time Interval; An Important Mortality Indicator in Peptic Ulcer Perforation.

    Science.gov (United States)

    Surapaneni, Sushama; S, Rajkumar; Reddy A, Vijaya Bhaskar

    2013-05-01

    To find out the significance of the Perforation-Operation Interval (POI) with respect to an early prognosis, in patients with peritonitis which is caused by peptic ulcer perforation. Case series. Place and Duration of the Study: Department of General Surgery, Konaseema Institute of Medical Sciences and RF Amalapuram, Andhra Pradesh, India from 2008-2011. This study included 150 patients with generalized peritonitis, who were diagnosed to have Perforated Peptic Ulcers (PPUs). The diagnosis of the PPUs was established on the basis of the history , the clinical examination and the radiological findings. The perforation-operation interval was calculated from the time of onset of the symptoms like severe abdominal pain or vomiting till the time the patient was operated. Out of the 150 patients 134 were males and 16 were females, with a male : female ratio of 9:1. Their ages ranged between 25-70 years. Out of the 150 patients, 65 patients (43.3%) presented within 24 hours of the onset of severe abdominal pain (Group A), 27 patients (18%) presented between 24-48 hours of the onset of severe abdominal pain (Group B) and 58 patients (38.6%) presented after 48 hours. There was no mortality in Group A and the morbidity was more in Group B and Group C. There were 15 deaths in Group C. The problem of peptic ulcer perforation with its complication, can be decreased by decreasing the perforation -operation time interval, which as per our study, appeared to be the single most important mortality and morbidity indicator in peptic ulcer perforation.

  9. A new generation of real-time DOS technology for mission-oriented system integration and operation

    Science.gov (United States)

    Jensen, E. Douglas

    1988-01-01

    Information is given on system integration and operation (SIO) requirements and a new generation of technical approaches for SIO. Real-time, distribution, survivability, and adaptability requirements and technical approaches are covered. An Alpha operating system program management overview is outlined.

  10. Operative time and cost of resident surgical experience: effect of instituting an otolaryngology residency program.

    Science.gov (United States)

    Pollei, Taylor R; Barrs, David M; Hinni, Michael L; Bansberg, Stephen F; Walter, Logan C

    2013-06-01

    Describe the procedure length difference between surgeries performed by an attending surgeon alone compared with the resident surgeon supervised by the same attending surgeon. Case series with chart review. Tertiary care center and residency program. Six common otolaryngologic procedures performed between August 1994 and May 2012 were divided into 2 cohorts: attending surgeon alone or resident surgeon. This division coincided with our July 2006 initiation of an otolaryngology-head and neck surgery residency program. Operative duration was compared between cohorts with confounding factors controlled. In addition, the direct result of increased surgical length on operating room cost was calculated and applied to departmental and published resident case log report data. Five of the 6 procedures evaluated showed a statistically significant increase in surgery length with resident involvement. Operative time increased 6.8 minutes for a cricopharyngeal myotomy (P = .0097), 11.3 minutes for a tonsillectomy (P operative time difference. Cost of increased surgical time was calculated per surgery and ranged from $286 (cricopharyngeal myotomy) to $2142 (mastoidectomy). When applied to reported national case log averages for graduating residents, this resulted in a significant increase of direct training-related costs. Resident participation in the operating room results in increased surgical length and additional system cost. Although residency is a necessary part of surgical training, associated costs need to be acknowledged.

  11. Does Full Wound Rupture following Median Pilonidal Closure Alter Long-Term Recurrence Rate?

    Science.gov (United States)

    Doll, Dietrich; Matevossian, Edouard; Luedi, Markus M; Schneider, Ralf; van Zypen, Dominic; Novotny, Alexander

    2015-01-01

    The purpose of this study was to examine the recurrence rate of wound rupture in primary pilonidal sinus disease (PSD) after median closure. A total of 583 patients from the German military cohort were interviewed. We compared the choice of surgical therapy, wound dehiscence (if present) and long-term recurrence-free survival for patients with primary open treatment, marsupialization and primary median treatment (closed vs. secondary open, respectively). Actuarial recurrence rate was determined using the Kaplan-Meier calculation with a follow-up of up to 20 years after primary PSD surgery. Patients with excision followed by primary open wound treatment showed a significantly lower 5- than 10-year recurrence rate (8.3 vs. 11.2%) compared to the patients with primary midline closure (17.4 vs. 20.5%, p = 0.03). The 20-year recurrence rate was 28% in primary open wound treatment versus 44% in primary midline closure without wound rupture. In contrast to these findings, long-term recurrence rates following secondary open wound treatment (12.2% at 5 years vs. 17.1% at 10 years) tended to be higher (although not significantly, p = 0.57) compared to primary open treatment (8.3% at 5 years vs. 11.2% at 10 years). There was no statistical difference in long-term recurrence rates between secondary open and primary midline closure (p = 0.7). Hence, despite only a short wound closure time experienced before wound rupture, the patient does not fully benefit from an open wound treatment in terms of recurrence rate. The postoperative pilonidal sinus wound rupture of primary midline closures did not significantly increase the 5- and 10-year long-term recurrence rates compared to uneventfully healing primary midline closures. © 2015 S. Karger AG, Basel.

  12. THERMAL HYDRAULIC ISSUES OF CONTAINMENT FILTERED VENTING SYSTEM FOR A LONG OPERATING TIME

    Directory of Open Access Journals (Sweden)

    YOUNG SU NA

    2014-12-01

    Full Text Available This study investigated the thermal hydraulic issues in the Containment Filtered Venting System (CFVS for a long operating time using the MELCOR computer code. The modeling of the CFVS, including the models for pool scrubbing and the filter, was added to the input file for the OPR-1000, and a Station Blackout (SBO was chosen as an accident scenario. Although depressurization in the containment building as a primary objective of the CFVS was successful, the decontamination feature by scrubbing and filtering in the CFVS for a long operating time could fail by the continuous evaporation of the scrubbing solution. After the operation of the CFVS, the atmosphere temperature in the CFVS became slightly above the water saturation temperature owing to the release of an amount of steam with high temperature from the containment building to the scrubbing solution. Reduced pipe diameters at the inlet and outlet of the CFVS vessel mitigated the evaporation of scrubbing water by controlling the amount of high-temperature steam and the water saturation temperature.

  13. Estudio del comportamiento de zapatas de medianería con viga centradora mediante modelos de elementos finitos

    OpenAIRE

    Galletero Montero, Pablo; Fernandez Gomez, Jaime Antonio; Perepérez Ventura, Bernardo

    2014-01-01

    Investigación sobre el cálculo de zapatas de medianería utilizando métodos no convencionales. Las dos soluciones más empleadas en edificación para el problema de las cimentaciones de medianería son la utilización de una viga centradora que conecta la zapata de medianería con la zapata del pilar interior más próximo y la colaboración de la viga de la primera planta trabajando como tirante. Los modelos convencionales existentes para el cálculo de este tipo de cimentaciones presentan una serie d...

  14. Median prior constrained TV algorithm for sparse view low-dose CT reconstruction.

    Science.gov (United States)

    Liu, Yi; Shangguan, Hong; Zhang, Quan; Zhu, Hongqing; Shu, Huazhong; Gui, Zhiguo

    2015-05-01

    It is known that lowering the X-ray tube current (mAs) or tube voltage (kVp) and simultaneously reducing the total number of X-ray views (sparse view) is an effective means to achieve low-dose in computed tomography (CT) scan. However, the associated image quality by the conventional filtered back-projection (FBP) usually degrades due to the excessive quantum noise. Although sparse-view CT reconstruction algorithm via total variation (TV), in the scanning protocol of reducing X-ray tube current, has been demonstrated to be able to result in significant radiation dose reduction while maintain image quality, noticeable patchy artifacts still exist in reconstructed images. In this study, to address the problem of patchy artifacts, we proposed a median prior constrained TV regularization to retain the image quality by introducing an auxiliary vector m in register with the object. Specifically, the approximate action of m is to draw, in each iteration, an object voxel toward its own local median, aiming to improve low-dose image quality with sparse-view projection measurements. Subsequently, an alternating optimization algorithm is adopted to optimize the associative objective function. We refer to the median prior constrained TV regularization as "TV_MP" for simplicity. Experimental results on digital phantoms and clinical phantom demonstrated that the proposed TV_MP with appropriate control parameters can not only ensure a higher signal to noise ratio (SNR) of the reconstructed image, but also its resolution compared with the original TV method. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Patient delay is the main cause of treatment delay in acute limb ischemia: an investigation of pre- and in-hospital time delay

    DEFF Research Database (Denmark)

    Londero, Louise Skovgaard; Nørgaard, Birgitte; Houlind, Kim Christian

    2014-01-01

    Abstract BACKGROUND: The prognosis of acute limb ischemia is severe, with amputation rates of up to 25% and in-hospital mortality of 9-15%. Delay in treatment increases the risk of major amputation and may be present at different stages, including patient delay, doctors´ delay and waiting time...... in the emergency department. It is important to identify existing problems in order to reduce time delay. The aim of this study was to collect data for patients with acute limb ischemia and to evaluate the time delay between the different events from onset of symptoms to specialist evaluation and further treatment...... (median (range)) was identified. From onset of symptoms to first contact with a doctor the time for all patients were 24 (0-1200) hours. Thirty patients needed immediate intervention. In the group of fourteen patients who had immediate operation, the median time from vascular evaluation...

  16. Effect of operational cycle time length on nitrogen removal in an alternating oxidation ditch system.

    Science.gov (United States)

    Mantziaras, I D; Stamou, A; Katsiri, A

    2011-06-01

    This paper refers to nitrogen removal optimization of an alternating oxidation ditch system through the use of a mathematical model and pilot testing. The pilot system where measurements have been made has a total volume of 120 m(3) and consists of two ditches operating in four phases during one cycle and performs carbon oxidation, nitrification, denitrification and settling. The mathematical model consists of one-dimensional mass balance (convection-dispersion) equations based on the IAWPRC ASM 1 model. After the calibration and verification of the model, simulation system performance was made. Optimization is achieved by testing operational cycles and phases with different time lengths. The limits of EU directive 91/271 for nitrogen removal have been used for comparison. The findings show that operational cycles with smaller time lengths can achieve higher nitrogen removals and that an "equilibrium" between phase time percentages in the whole cycle, for a given inflow, must be achieved.

  17. Donation return time at fixed and mobile donation sites

    Science.gov (United States)

    Carey, Patricia M.; High, Patrick M.; Schlumpf, Karen S.; Johnson, Bryce R.; Mast, Alan E.; Rios, Jorge A.; Simon, Toby L.; Wilkinson, Susan L.

    2013-01-01

    BACKGROUND This study investigated the effect of blood donation environment, fixed or mobile with differing sponsor types, on donation return time. STUDY DESIGN AND METHODS Data from 2006 through 2009 at six US blood centers participating in the Retrovirus Epidemiology Donor Study-II (REDS-II) were used for analysis. Descriptive statistics stratified by whole blood (WB), plateletpheresis (PP), and double red blood cell (R2) donations were obtained for fixed and mobile locations, including median number of donations and median interdonation interval. A survival analysis estimated median return time at fixed and mobile sites, while controlling for censored return times, demographics, blood center, and mandatory recovery times. RESULTS Two-thirds (67.9%) of WB donations were made at mobile sites, 97.4% of PP donations were made at fixed sites, and R2 donations were equally distributed between fixed and mobile locations. For donations at fixed sites only or alternating between fixed and mobile sites, the highest median numbers of donations were nine and eight, respectively, and the shortest model-adjusted median return times (controlling for mandatory eligibility times of 56 and 112 days) were 36 and 30 days for WB and R2 donations, respectively. For PP donations, the shortest model-adjusted median return time was 23 days at a fixed location and the longest was 693 days at community locations. CONCLUSION WB, PP, and R2 donors with the shortest time between donations were associated with fixed locations and those alternating between fixed and mobile locations, even after controlling for differing mandatory recovery times for the different blood donation procedures. PMID:21745215

  18. Synthesis document on the long time behavior of packages: operational document ''bituminous'' 2204

    International Nuclear Information System (INIS)

    Tiffreau, C.

    2004-09-01

    This document is realized in the framework of the law of 1991 on the radioactive wastes management. The 2004 synthesis document on long time behavior of bituminous sludges packages is constituted by two documents, the reference document and the operational document. This paper presents the operational model describing the water alteration of the packages and the associated radioelements release, as the gas term source and the swelling associated to the self-irradiation and the bituminous radiolysis. (A.L.B.)

  19. Comparison of laparoscopic and open appendectomy in terms of operative time, hospital stay and frequency of surgical site infection

    International Nuclear Information System (INIS)

    Ibrahim, T.; Saleem, M.R.; Aziz, O.B.; Arshad, A.

    2014-01-01

    To compare laparoscopic and conventional open appendectomy in terms of operative time, hospital stay and frequency of surgical site infection (SSI). Patient and Methods: A total of 417 patients underwent appendectomy during this period. 137 patients underwent laparoscopic appendectomy (group A) while 280 patient had open appendectomy (group B). The samples include all patients who were operated open between the time span of june 2010 to september 2011. A chi square-test was performed to compare the data for statistical significance. Result: Mean operative time for group A was 79.21+-23.42 minitues where as in group B, the mean operative time was 41.49+-20.86 minitues. Group A patients had a shorter hospital 1 stay (3.6+-1 day) but in group B it was (5.2+-3 days). Seven patients (5.1 %) developed surgical site infection (SSI) in group A and 34 patients (12.14 %)developed postoperative SSI in group B. Conclusion: Laparoscopic appendectomy is superior to open appendectomy because of shorter hospital stay and laser-operative SSI, but requires longer operative time. (author)

  20. A median filter approach for correcting errors in a vector field

    Science.gov (United States)

    Schultz, H.

    1985-01-01

    Techniques are presented for detecting and correcting errors in a vector field. These methods employ median filters which are frequently used in image processing to enhance edges and remove noise. A detailed example is given for wind field maps produced by a spaceborne scatterometer. The error detection and replacement algorithm was tested with simulation data from the NASA Scatterometer (NSCAT) project.

  1. Optimal operation of smart houses by a real-time rolling horizon algorithm

    NARCIS (Netherlands)

    Paterakis, N.G.; Pappi, I.N.; Catalão, J.P.S.; Erdinc, O.

    2016-01-01

    In this paper, a novel real-time rolling horizon optimization framework for the optimal operation of a smart household is presented. A home energy management system (HEMS) model based on mixed-integer linear programming (MILP) is developed in order to minimize the energy procurement cost considering

  2. Non-Markovian finite-temperature two-time correlation functions of system operators of a pure-dephasing model

    International Nuclear Information System (INIS)

    Goan, Hsi-Sheng; Jian, Chung-Chin; Chen, Po-Wen

    2010-01-01

    We evaluate the non-Markovian finite-temperature two-time correlation functions (CF's) of system operators of a pure-dephasing spin-boson model in two different ways, one by the direct exact operator technique and the other by the recently derived evolution equations, valid to second order in the system-environment interaction Hamiltonian. This pure-dephasing spin-boson model that is exactly solvable has been extensively studied as a simple decoherence model. However, its exact non-Markovian finite-temperature two-time system operator CF's, to our knowledge, have not been presented in the literature. This may be mainly due to the fact, illustrated in this article, that in contrast to the Markovian case, the time evolution of the reduced density matrix of the system (or the reduced quantum master equation) alone is not sufficient to calculate the two-time system operator CF's of non-Markovian open systems. The two-time CF's obtained using the recently derived evolution equations in the weak system-environment coupling case for this non-Markovian pure-dephasing model happen to be the same as those obtained from the exact evaluation. However, these results significantly differ from the non-Markovian two-time CF's obtained by wrongly directly applying the quantum regression theorem (QRT), a useful procedure to calculate the two-time CF's for weak-coupling Markovian open systems. This demonstrates clearly that the recently derived evolution equations generalize correctly the QRT to non-Markovian finite-temperature cases. It is believed that these evolution equations will have applications in many different branches of physics.

  3. Time evolution of plasma potential in pulsed operation of ECRIS

    International Nuclear Information System (INIS)

    Tarvainen, O.; Koivisto, H.; Ropponen, T.; Toivanen, V.; Higurashi, Y.; Nakagawa, T.

    2012-01-01

    The time evolution of plasma potential has been measured with a retarding field analyzer in pulsed operation mode with electron cyclotron resonance ion sources at JYFL and RIKEN. Three different ion sources with microwave frequencies ranging from 6.4 to 18 GHz were employed for the experiments. The plasma potential was observed to increase 10-75 % during the Pre-glow and 10-30 % during the afterglow compared to steady state. The paper is followed by the slides of the presentation. (authors)

  4. Programming a real-time operating system for satellite control applications Satellite Control Applications

    International Nuclear Information System (INIS)

    Omer, M.; Anjum, O.; Suddle, M.R.

    2004-01-01

    With the realization of ideas like formation flights and multi-body space vehicles the demands on an attitude control system have become increasingly complex. Even in its most simplified form, the control system for a typical geostationary satellite has to run various supervisory functions along with determination and control algorithms side by side. Within each algorithm it has to employ multiple actuation and sensing mechanisms and service real time interrupts, for example, in the case of actuator saturation and sensor data fusion. This entails the idea of thread scheduling and program synchronization, tasks specifically meant for a real time OS. This paper explores the embedding of attitude determination and control loop within the framework of a real time operating system provided for TI's DSP C6xxx series. The paper details out the much functionality provided within the scaleable real time kernel and the analysis and configuration tools available, It goes on to describe a layered implementation stack associated with a typical control for Geo Stationary satellites. An application for control is then presented in which state of the art analysis tools are employed to view program threads, synchronization semaphores, hardware interrupts and data exchange pipes operating in real time. (author)

  5. Prevalence of ulnar-to-median nerve motor fiber anastomosis (Riché-Cannieu communicating branch) in hand: An electrophysiological study

    Science.gov (United States)

    Ahadi, Tannaz; Raissi, Gholam Reza; Yavari, Masood; Majidi, Lobat

    2016-01-01

    Background: Two main muscles studied in the hand for evaluation of median nerve injuries are opponens pollicis (OP) and abductor pollicis brevis (APB). However, Riché-Cannieu communicating branch (RCCB) may limit the use of these muscles in electrodiagnosis. This condition is confusing in the case of median nerve injuries. This study was conducted to evaluate the prevalence of RCCB. Methods: Twenty-three consecutive cases of complete median nerve injury were studied. Evoked responses via stimulation of median and ulnar nerves in the wrist and recording with needle in the thenar area were studied. Results: Of the patients, 82.6% exhibited RCCB. In 14 (60.8%) cases the OP and in 19(82.6%) cases APB was supplied by the ulnar nerve. Conclusion: RCCB was detected to be 60.8% in OP and 82.6% in APB, so OP is preferable to APB in the study of median nerve. PMID:27390694

  6. A Study on Evaluation Issues of Real-Time Operating System in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, Y. M.; Jeong, C. H.; Koh, J. S.

    2006-01-01

    Control applications such as aircraft, robotics and nuclear power plant have to maintain a very high level of safety, typically defined as the avoidance of unplanned events resulting in hazard. These applications usually operate with hard real-time operating system (RTOS). In this case, hard RTOS software should be reliable and safe. RTOS used in safety-critical I and C system is the base software for the purpose of satisfying the real-time constraints. So, careful evaluation of its safety and functionality is very important. In this paper, we present the case study for RTOSs used in real nuclear power plants (NPP), and suggest the evaluation approach for the RTOS

  7. A Study on Evaluation Issues of Real-Time Operating System in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. M.; Jeong, C. H.; Koh, J. S. [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of)

    2006-07-01

    Control applications such as aircraft, robotics and nuclear power plant have to maintain a very high level of safety, typically defined as the avoidance of unplanned events resulting in hazard. These applications usually operate with hard real-time operating system (RTOS). In this case, hard RTOS software should be reliable and safe. RTOS used in safety-critical I and C system is the base software for the purpose of satisfying the real-time constraints. So, careful evaluation of its safety and functionality is very important. In this paper, we present the case study for RTOSs used in real nuclear power plants (NPP), and suggest the evaluation approach for the RTOS.

  8. Gas-fired power plants: Investment timing, operating flexibility and CO2 capture

    International Nuclear Information System (INIS)

    Fleten, Stein-Erik; Naesaekkaelae, Erkka

    2010-01-01

    We analyze investments in gas-fired power plants based on stochastic electricity and natural gas prices. A simple but realistic two-factor model is used for price processes, enabling analysis of the value of operating flexibility, the opportunity to abandon the capital equipment, as well as finding thresholds for energy prices for which it is optimal to enter into the investment. We develop a method to compute upper and lower bounds on plant values and investment threshold levels. Our case study uses representative power plant investment and operations data, and historical forward prices from well-functioning energy markets. We find that when the decision to build is considered, the abandonment option does not have significant value, whereas the operating flexibility and time-to-build option have significant effect on the building threshold. Furthermore, the joint value of the operating flexibility and the abandonment option is much smaller than the sum of their separate values, because both are options to shut down. The effects of emission costs on the value of installing CO 2 capture technology are also analyzed.

  9. The prevalence of median neuropathy at wrist in systemic sclerosis patients at Srinagarind Hospital

    Directory of Open Access Journals (Sweden)

    Thanaporn Nimitbancha

    2015-01-01

    Full Text Available Objectives: To determine the prevalence and factor related with median neuropathy at wrist (MNW in systemic sclerosis patients. Study Design: Cross-sectional study. Setting: Srinagarind Hospital, Khon Kaen, Thailand. Participants: Systemic sclerosis patients who attended the Scleroderma Clinic, Srinagarind Hospital. Materials and Methods: Seventyfive systemic sclerosis patients were prospectively evaluated by questionnaire, physical examination, and electrodiagnostic study. The questionnaire consisted of the symptoms, duration, and type of systemic sclerosis. The physical examination revealed skin score of systemic sclerosis, pinprick sensation of median nerve distribution of both hands, and weakness of both abductor pollicis brevis muscles. The provocative test which were Tinel′s sign and Phalen′s maneuver were also examined. Moreover, electrodiagnostic study of the bilateral median and ulnar nerves was conducted. Results: The prevalence of MNW in systemic sclerosis patients was 44% - percentage of mild, moderate, and severe were 28%, 9.3%, and 6.7%, respectively. The prevalence of asymptomatic MNW was 88%. There were no association between the presence of MNW and related factors of systemic sclerosis. Conclusions: MNW is one of the most common entrapment neuropathies in systemic sclerosis patients. Systemic sclerosis patients should be screened for early signs of MNW.

  10. Remaining useful life estimation for deteriorating systems with time-varying operational conditions and condition-specific failure zones

    Directory of Open Access Journals (Sweden)

    Li Qi

    2016-06-01

    Full Text Available Dynamic time-varying operational conditions pose great challenge to the estimation of system remaining useful life (RUL for the deteriorating systems. This paper presents a method based on probabilistic and stochastic approaches to estimate system RUL for periodically monitored degradation processes with dynamic time-varying operational conditions and condition-specific failure zones. The method assumes that the degradation rate is influenced by specific operational condition and moreover, the transition between different operational conditions plays the most important role in affecting the degradation process. These operational conditions are assumed to evolve as a discrete-time Markov chain (DTMC. The failure thresholds are also determined by specific operational conditions and described as different failure zones. The 2008 PHM Conference Challenge Data is utilized to illustrate our method, which contains mass sensory signals related to the degradation process of a commercial turbofan engine. The RUL estimation method using the sensor measurements of a single sensor was first developed, and then multiple vital sensors were selected through a particular optimization procedure in order to increase the prediction accuracy. The effectiveness and advantages of the proposed method are presented in a comparison with existing methods for the same dataset.

  11. Supporting Real-Time Operations and Execution through Timeline and Scheduling Aids

    Science.gov (United States)

    Marquez, Jessica J.; Pyrzak, Guy; Hashemi, Sam; Ahmed, Samia; McMillin, Kevin Edward; Medwid, Joseph Daniel; Chen, Diana; Hurtle, Esten

    2013-01-01

    Since 2003, the NASA Ames Research Center has been actively involved in researching and advancing the state-of-the-art of planning and scheduling tools for NASA mission operations. Our planning toolkit SPIFe (Scheduling and Planning Interface for Exploration) has supported a variety of missions and field tests, scheduling activities for Mars rovers as well as crew on-board International Space Station and NASA earth analogs. The scheduled plan is the integration of all the activities for the day/s. In turn, the agents (rovers, landers, spaceships, crew) execute from this schedule while the mission support team members (e.g., flight controllers) follow the schedule during execution. Over the last couple of years, our team has begun to research and validate methods that will better support users during realtime operations and execution of scheduled activities. Our team utilizes human-computer interaction principles to research user needs, identify workflow processes, prototype software aids, and user test these. This paper discusses three specific prototypes developed and user tested to support real-time operations: Score Mobile, Playbook, and Mobile Assistant for Task Execution (MATE).

  12. A multi-disciplinary assessment of operator action time for mitigating a postulated accident

    International Nuclear Information System (INIS)

    Morgan, C.D.; Fields, C.C.; Hightower, N.T. III; Buczek, J.A.; Jenkins, T.B.; Swanson, P.J.

    1992-01-01

    This report discusses mitigation of the postulated Loss of Heat Sink Accident for the Savannah River Site K Reactor which requires operator action to place the plant in a water conservation configuration. In August 1991, concerns were raised about the allowances in the safety analyses for operator action times in an unpowered scenario, where several valves would be manually closed. WSRC management conservatively decided to include explicit consideration of a seismic initiator for this scenario, which introduced the additional concern that operator actions could be hindered by tritium from flange leakage. The revised analyses concluded that the powered case documented in the Safety Analysis Report is limiting and that all acceptance criteria are met

  13. On-line diagnostic techniques for air-operated control valves based on time series analysis

    International Nuclear Information System (INIS)

    Ito, Kenji; Matsuoka, Yoshinori; Minamikawa, Shigeru; Komatsu, Yasuki; Satoh, Takeshi.

    1996-01-01

    The objective of this research is to study the feasibility of applying on-line diagnostic techniques based on time series analysis to air-operated control valves - numerous valves of the type which are used in PWR plants. Generally the techniques can detect anomalies by failures in the initial stages for which detection is difficult by conventional surveillance of process parameters measured directly. However, the effectiveness of these techniques depends on the system being diagnosed. The difficulties in applying diagnostic techniques to air-operated control valves seem to come from the reduced sensitivity of their response as compared with hydraulic control systems, as well as the need to identify anomalies in low level signals that fluctuate only slightly but continuously. In this research, simulation tests were performed by setting various kinds of failure modes for a test valve with the same specifications as of a valve actually used in the plants. Actual control signals recorded from an operating plant were then used as input signals for simulation. The results of the tests confirmed the feasibility of applying on-line diagnostic techniques based on time series analysis to air-operated control valves. (author)

  14. Hotellin ravitsemispalveluiden markkinointiviestinnän kehittäminen sosiaalisen median keinoin, esimerkkinä case: Digihotelli

    OpenAIRE

    Ruokolainen, Anita

    2014-01-01

    Opinnäytetyössä kehitetään hotellin ravitsemispalveluiden markkinointiviestintää sosiaalisen median tarjoamin keinoin. Työn toimeksiantaja on majoitus- ja ravitsemispalveluita tarjoava yritys. Työn tavoitteena on laatia konkreettisia kehitysideoita markkinointiviestintää varten. Lisäksi tavoitteena on kehittää uusia tapoja hyödyntää sosiaalista mediaa yrityksen markkinointiviestinnässä. Työssä perehdytään myös sosiaalisen median uusiin trendeihin ja kehityssuuntiin. Työn teoreettinen vii...

  15. Data Visualization of Item-Total Correlation by Median Smoothing

    Directory of Open Access Journals (Sweden)

    Chong Ho Yu

    2016-02-01

    Full Text Available This paper aims to illustrate how data visualization could be utilized to identify errors prior to modeling, using an example with multi-dimensional item response theory (MIRT. MIRT combines item response theory and factor analysis to identify a psychometric model that investigates two or more latent traits. While it may seem convenient to accomplish two tasks by employing one procedure, users should be cautious of problematic items that affect both factor analysis and IRT. When sample sizes are extremely large, reliability analyses can misidentify even random numbers as meaningful patterns. Data visualization, such as median smoothing, can be used to identify problematic items in preliminary data cleaning.

  16. Infinite set of relevant operators for an exact solution of the time-dependent Jaynes-Cummings Hamiltonian

    International Nuclear Information System (INIS)

    Gruver, J.L.; Aliaga, J.; Cerdeira, H.A.; Proto, A.N.

    1995-03-01

    The dynamics and thermodynamics of a quantum time-dependent field coupled to a two-level system, well known as the Jaynes-Cummings Hamiltonian, is studied, using the maximum entropy principle. In the framework of this approach we found three different infinite sets of relevant operators that describe the dynamics of the system for any temporal dependence. These sets of relevant operators are connected by isomorphisms, which allow us to consider the case of mixed initial conditions. A consistent set of initial conditions is established using the maximum entropy principle density operator, obtaining restrictions to the physically feasible initial conditions of the system. The behaviour of the population inversion is shown for different time dependencies of the Hamiltonian and initial conditions. For the time-independent case, an explicit solution for the population inversion in terms of the relevant operators of one of the sets is given. It is also shown how the well-known formulas for the population inversion are recovered for the special cases where the initial conditions correspond to a pure, coherent, and thermal field. (author). 35 refs, 9 figs

  17. A Retrospective Study of Success, Failure, and Time Needed to Perform Awake Intubation.

    Science.gov (United States)

    Joseph, Thomas T; Gal, Jonathan S; DeMaria, Samuel; Lin, Hung-Mo; Levine, Adam I; Hyman, Jaime B

    2016-07-01

    Awake intubation is the standard of care for management of the anticipated difficult airway. The performance of awake intubation may be perceived as complex and time-consuming, potentially leading clinicians to avoid this technique of airway management. This retrospective review of awake intubations at a large academic medical center was performed to determine the average time taken to perform awake intubation, its effects on hemodynamics, and the incidence and characteristics of complications and failure. Anesthetic records from 2007 to 2014 were queried for the performance of an awake intubation. Of the 1,085 awake intubations included for analysis, 1,055 involved the use of a flexible bronchoscope. Each awake intubation case was propensity matched with two controls (1:2 ratio), with similar comorbidities and intubations performed after the induction of anesthesia (n = 2,170). The time from entry into the operating room until intubation was compared between groups. The anesthetic records of all patients undergoing awake intubation were also reviewed for failure and complications. The median time to intubation for patients intubated post induction was 16.0 min (interquartile range: 13 to 22) from entrance into the operating room. The median time to intubation for awake patients was 24.0 min (interquartile range: 19 to 31). The complication rate was 1.6% (17 of 1,085 cases). The most frequent complications observed were mucous plug, endotracheal tube cuff leak, and inadvertent extubation. The failure rate for attempted awake intubation was 1% (n = 10). Awake intubations have a high rate of success and low rate of serious complications and failure. Awake intubations can be performed safely and rapidly.

  18. Ciliated median raphe cyst of perineum presenting as perianal polyp: a case report with immunohistochemical study, review of literature, and pathogenesis.

    Science.gov (United States)

    Sagar, Jayesh; Sagar, Bethani; Patel, Adam F; Shak, D K

    2006-03-05

    Median raphe cyst is a very rare, benign congenital lesion occurring mainly on the ventral aspect of the penis, but can develop anywhere in the midline between the external urethral meatus and anus. We report a case of median raphe cyst in the perineum presenting as a perianal polyp in a 65-year-old, English white male with exceptionally rare ciliated epithelium. According to our knowledge, this is the third such case of ciliated median raphe cyst in the English literature. This case, also the first case of ciliated median raphe cyst in the perineum location, focuses on pathogenesis of median raphe cyst.

  19. Bascoms operation for pilonidalcyste

    DEFF Research Database (Denmark)

    Bertelsen, C.A.; Jørgensen, Lars Nannestad

    2008-01-01

    . MATERIALS AND METHODS: 59 patients (53 male) underwent surgery between September 2004 and January 2007. The median age was 27.7 (16-48) years. The indication for surgery was recurrent pilonidal cysts in 17 cases, impaired wound healing after prior surgery in 7 cases and large cysts in 35 cases. RESULTS: All......INTRODUCTION: Treatment of pilonidal fistula often results in impaired wound healing and recurrence. After wide excision of the fistula, impaired healing and recurrence occur in up to 69% and 10-29% of cases, respectively. Based on these facts we decided to implement Bascom's cleft-lift operation...... reoperation due to infection, but none of these patients received postoperative antibiotics. 26 (44%) patients developed minor wound defects. In 22 (85%) of these cases, the wounds healed spontaneously in less than 3 months. 42 patients were followed for more than 6 months with a median follow-up of 19 (8...

  20. Changes in operating time of modern domestic EKG exсavators in dependence of their functioning conditions

    Directory of Open Access Journals (Sweden)

    С. Л. Иванов

    2016-11-01

    Full Text Available Domestically produced opencast excavators are shown to be serious competition for foreign hydraulic machinery. It is suggested to estimate the potential of an opencast excavator via its basic operation effectiveness factor equal to the ratio of the scoop payload to the nominal cost of excavator operations under its normal operational conditions. Comparing the theoretical values of standard operations of hydraulic excavators of the third type-and-size group during coal mining with domestically produced EKG-18R on their operation effectiveness factor shows that the excavator exceeds foreign hydraulic models from that group 2.7-3.3 times. Theoretical foundation is provided for a complex of factors that affect the operating time of single scoop open- cast excavators, a structure is offered for the model of comprehensive assessment of operating time for opencast excavators. Complex indicators are substantiated and proposed for supporting operational effectiveness of such excavators. Assessment is offered of operational effectiveness of EKG-18R excavators following the criterion of energy consumption per excavation of a unit of rock mass. Generalization analysis is given of a set of factors that affect the value of operating time for EKG-18R excavators. Proposals are put forward on upgrading the regulations for technical maintenance and repairs of EKG-18R excavators. The task of assessing the technical state of machinery calls for using integral criteria that would enable one to identify the current technical state and the residual resource of machine aggregates, their failure potentially resulting in emergency situations accompanied by considerable property damage. It is feasible to use an integrated indicator of the degree of degradation of s machinery item for such an integrated indicator, retrieved in the course of assessing the current technical state of that item during diagnostic procedures. In its turn, such and integral indicator of the state

  1. Management of colorectal injuries during operation iraqi freedom: patterns of stoma usage.

    Science.gov (United States)

    Duncan, James E; Corwin, Christian H; Sweeney, W Brian; Dunne, James R; Denobile, John W; Perdue, Philip W; Galarneau, Michael R; Pearl, Jonathan P

    2008-04-01

    Management of penetrating colorectal injuries in the civilian trauma population has evolved away from diversionary stoma into primary repair or resection and primary anastomosis. With this in mind, we evaluated how injuries to the colon and rectum were managed in the ongoing war in Iraq. The records of Operation Iraqi Freedom patients evacuated to National Naval Medical Center (NNMC) from March 2004 until November 2005 were retrospectively reviewed. Patients with colorectal injuries were identified and characterized by the following: (1) injury type; (2) mechanism; (3) associated injuries; (4) Injury Severity Score; (5) levels of medical care involved in patient treatment; (6) time interval(s) between levels of care; (7) management; and (8) outcomes. Twenty-three patients were identified as having either colon or rectal injury. The average ISS was 24.4 (range, 9-54; median 24). On average, patients were evaluated and treated at 2.5 levels of surgically capable medical care (range, 2-3; median 2) between time of injury and arrival at NNMC, with a median of 6 days from initial injury until presentation at NNMC (range, 3-11). Management of colorectal injuries included 7 primary repairs (30.4%), 3 resections with anastomoses (13.0%), and 13 colostomies (56.6%). There was one death (4.3%) and three anastomotic leaks (30%). Total complication rate was 48%. Based upon injury severity, the complex nature of triage and medical evacuation, and the multiple levels of care involved for injured military personnel, temporary stoma usage should play a greater role in military casualties than in the civilian environment for penetrating colorectal injuries.

  2. Academic versus Clinical Productivity of Cardiac Surgeons in the State of New York: Who Publishes More and Who Operates More.

    Science.gov (United States)

    Rosati, Carlo Maria; Gaudino, Mario; Vardas, Panos N; Weber, Daniel J; Blitzer, David; Hameedi, Fawad; Koniaris, Leonidas G; Girardi, Leonard N

    2018-01-01

    We investigated whether/how cardiac surgeons can be productive both academically and clinically. Using online resources (New York State Adult Cardiac Surgery database, SCOPUS), we collected individual clinical volumes (operations performed/year), academic metrics (ongoing publications, role as author), practice setting, and seniority for all cardiac surgeons in the State of New York from 1994 to 2011. Over time, individual clinical volumes decreased (median operations/year: 193 in 1995 vs 126 in 2010; P published more worked at hospitals with higher clinical volumes (Spearman's correlation coefficient: 0.16; P publishing at all; ∼45 per cent operating less, but publishing a little; ∼15 per cent clinically very productive (operating as much as the nonpublishers) and publishing a lot; and ∼1 per cent operating the least, but publishing the most.

  3. Efficient implementation of real-time programs under the VAX/VMS operating system

    Science.gov (United States)

    Johnson, S. C.

    1985-01-01

    Techniques for writing efficient real-time programs under the VAX/VMS oprating system are presented. Basic operations are presented for executing at real-time priority and for avoiding needlless processing delays. A highly efficient technique for accessing physical devices by mapping to the input/output space and accessing the device registrs directly is described. To illustrate the application of the technique, examples are included of different uses of the technique on three devices in the Langley Avionics Integration Research Lab (AIRLAB): the KW11-K dual programmable real-time clock, the Parallel Communications Link (PCL11-B) communication system, and the Datacom Synchronization Network. Timing data are included to demonstrate the performance improvements realized with these applications of the technique.

  4. The space-time operator product expansion in string theory duals of field theories

    International Nuclear Information System (INIS)

    Aharony, Ofer; Komargodski, Zohar

    2008-01-01

    We study the operator product expansion (OPE) limit of correlation functions in field theories which possess string theory duals, from the point of view of the string worldsheet. We show how the interesting ('single-trace') terms in the OPE of the field theory arise in this limit from the OPE of the worldsheet theory of the string dual, using a dominant saddle point which appears in computations of worldsheet correlation functions in the space-time OPE limit. The worldsheet OPE generically contains only non-physical operators, but all the non-physical contributions are resummed by the saddle point to a contribution similar to that of a physical operator, which exactly matches the field theory expectations. We verify that the OPE limit of the worldsheet theory does not have any other contributions to the OPE limit of space-time correlation functions. Our discussion is completely general and applies to any local field theory (conformal at high energies) that has a weakly coupled string theory dual (with arbitrary curvature). As a first application, we compare our results to a proposal of R. Gopakumar for the string theory dual of free gauge theories

  5. Time Series Modeling of Human Operator Dynamics in Manual Control Tasks

    Science.gov (United States)

    Biezad, D. J.; Schmidt, D. K.

    1984-01-01

    A time-series technique is presented for identifying the dynamic characteristics of the human operator in manual control tasks from relatively short records of experimental data. Control of system excitation signals used in the identification is not required. The approach is a multi-channel identification technique for modeling multi-input/multi-output situations. The method presented includes statistical tests for validity, is designed for digital computation, and yields estimates for the frequency response of the human operator. A comprehensive relative power analysis may also be performed for validated models. This method is applied to several sets of experimental data; the results are discussed and shown to compare favorably with previous research findings. New results are also presented for a multi-input task that was previously modeled to demonstrate the strengths of the method.

  6. A Comparison among Worker Types Using a Composites Approach and Median Splits

    Science.gov (United States)

    Aziz, Shahnaz; Wuensch, Karl L.; Brandon, Howard R.

    2010-01-01

    The current study examined Spence and Robbins' (1992) worker types in terms of correlates of workaholism (e.g., work-life imbalance, obsessive-compulsive behavior). A survey was administered to professionals, who were then classified into different worker types following the traditional median-split technique. The data were also analyzed with…

  7. Epithelioid Sarcoma of the Forearm Arising from Perineural Sheath of Median Nerve Mimicking Carpal Tunnel Syndrome

    Directory of Open Access Journals (Sweden)

    Hiromasa Fujii

    2009-01-01

    Full Text Available We report here a case of epithelioid sarcoma in the forearm of a 33-year-old male presenting with symptoms and signs of carpal tunnel syndrome originating from the direct involvement of the median nerve. Due to the slow growing of the tumor, the patient noticed the presence of tumor mass in his forearm after several months from the initial onset of the symptoms. Magnetic resonance imaging showed an 8×4 cm mass involving the median nerve in the middle part of the forearm, and histological analysis of the biopsy specimen revealed the diagnosis of epithelioid sarcoma. Radical surgical resection was performed in conjunction with adjuvant chemotherapy. The function of the flexors were restored by the multiple tendon transfers (EIP→FDS; ECRL→FDP; BrR→FPL; EDM→opponens with superficial cutaneous branch of radial nerve transfer to the resected median nerve. The function of the affected hand showed excellent with the DASH disability/symptom score of 22.5, and both the grasp power and sensory of the median nerve area has recovered up to 50% of the normal side. The patient returned to his original vocation and alive with continuous disease free at 3.5-year follow-up since initial treatment.

  8. Gynaecomastia and scrotal rhacosis: two aesthetic surgical operations for men in Byzantine times.

    Science.gov (United States)

    Papadakis, Marios; Manios, Andreas; de Bree, Eelco; Trompoukis, Constantinos; Tsiftsis, Dimitris D

    2010-08-01

    Nowadays, as in the past, much attention is paid to aesthetic operations in women, while only infrequently have such operations been referred to in males. Generally, male aesthetic surgery was introduced to surgical practise during the 19th century. In this study, we analysed the practise of such operations in Byzantine times and in other ancient cultures with surgical knowledge, i.e. ancient India and China The sixth book of Paul of Aegina's "Epitome of Medicine" was studied for description of aesthetic operations in males in the Byzantine period, since this book is completely devoted to surgery and is generally considered to be the most important reference for surgery in Byzantine times. The original text and its excellent translation by Francis Adams were used. References concerning aesthetic operations for males were identified. Accordingly, historical work and reviews on plastic surgery in ancient India and China were studied. Mainly, two aesthetic surgical procedures for males in the Byzantine period were identified. These two procedures comprise gynaecomastia and rhacosis (scrotal relaxation). Two different techniques were reported for the surgical management of gynaecomastia, through sub-mammary or supra-mammary access. Two procedures were noted for rhacosis, for which Paul of Aegina reproduced the respective chapters from Leonides' and Antyllus' works. Evidence supporting male aesthetic surgery in ancient India and China or elsewhere was not found. Despite the dubious aesthetic result, the existence of different aesthetic surgical techniques in males substantiate the advanced level of surgery achieved by physicians in the Byzantine period. Copyright 2010 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Ciliated Median Raphe Cyst of Perineum Presenting as Perianal Polyp: A Case Report with Immunohistochemical Study, Review of Literature, and Pathogenesis

    Directory of Open Access Journals (Sweden)

    Jayesh Sagar

    2006-01-01

    Full Text Available Median raphe cyst is a very rare, benign congenital lesion occurring mainly on the ventral aspect of the penis, but can develop anywhere in the midline between the external urethral meatus and anus. We report a case of median raphe cyst in the perineum presenting as a perianal polyp in a 65-year-old, English white male with exceptionally rare ciliated epithelium. According to our knowledge, this is the third such case of ciliated median raphe cyst in the English literature. This case, also the first case of ciliated median raphe cyst in the perineum location, focuses on pathogenesis of median raphe cyst.

  10. Operational Testing and Measurement of the Resolving Time of a Counting Assembly

    International Nuclear Information System (INIS)

    Manent, G.; Scheemaecker, J. de

    1968-01-01

    An experiment is described which constitutes a very sensitive test of the satisfactory operation of a counting assembly. It makes it possible to measure the resolving time of an assembly to an accuracy of 1 per cent. A certain number of examples are presented which show the sensitivity of the test. (author) [fr

  11. The potential use of unmanned aircraft systems (drones) in mountain search and rescue operations.

    Science.gov (United States)

    Karaca, Yunus; Cicek, Mustafa; Tatli, Ozgur; Sahin, Aynur; Pasli, Sinan; Beser, Muhammed Fatih; Turedi, Suleyman

    2018-04-01

    This study explores the potential use of drones in searching for and locating victims and of motorized transportation of search and rescue providers in a mountain environment using a simulation model. This prospective randomized simulation study was performed in order to compare two different search and rescue techniques in searching for an unconscious victim on snow-covered ground. In the control arm, the Classical Line Search Technique (CLT) was used, in which the search is performed on foot and the victim is reached on foot. In the intervention arm, the Drone-snowmobile Technique (DST) was used, the search being performed by drone and the victim reached by snowmobile. The primary outcome of the study was the comparison of the two search and rescue techniques in terms of first human contact time. Twenty search and rescue operations were conducted in this study. Median time to arrival at the mannequin was 57.3min for CLT, compared to 8.9min for DST. The median value of the total searched area was 88,322.0m 2 for CLT and 228,613.0m 2 for DST. The median area searched per minute was 1489.6m 2 for CLT and 32,979.9m 2 for DST (pdrone using DST compared to the classical technique, and the victim can be located faster and reached earlier with rescuers transported by snowmobile. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Salvage concurrent radio-chemotherapy for post-operative local recurrence of squamous-cell esophageal cancer

    International Nuclear Information System (INIS)

    Zhang, Jian; Gong, Youling; Peng, Feng; Li, Na; Liu, Yongmei; Xu, Yong; Zhou, Lin; Wang, Jin; Zhu, Jiang; Huang, Meijuan

    2012-01-01

    To evaluate the treatment outcome of salvage concurrent radio-chemotherapy for patients with loco-recurrent esophageal cancer after surgery. 50 patients with loco-recurrent squamous-cell cancer after curative esophagectomy were retrospectively analyzed. Patients were treated with radiotherapy (median 60 Gy) combined with chemotherapy consisting of either 5-fluorouracil (5-FU) plus cisplatin (DDP) (R-FP group) or paclitaxel plus DDP (R-TP group). The median follow-up period was 16.0 months. The 1-year and 3-year survival rates were 56% and 14%, respectively. The median progression-free survival (PFS) and overall survival (OS) time was 9.8 and 13.3 months respectively. There was no statistical significance of the PFS of the two groups. The OS (median 16.3 months) in the R-TP group was superior to that in the R-FP group (median: 9.8 months) (p = 0.012). Among the patients who had received ≥60 Gy irradiation dose, the median PFS (10.6 months) and OS (16.3 months) were significantly superior to the PFS (8.7 months) and OS (11.3 months) among those patients did not (all p < 0.05). Grade 3 treatment-related gastritis were observed in 6 (27.3%) and 7 (25%) patients in the R-FP and R-TP group respectively. By univariate survival analysis, the age (<60 years), TP regimen and higher irradiation dose might improve the OS of such patients in present study. For those patients with post-operative loco-recurrent squamous-cell esophageal carcinoma, radiotherapy combined with either FP or TP regimen chemotherapy was an effective salvage treatment. Younger age, treatment with the TP regimen and an irradiation dose ≥60 Gy might improve the patients’ treatment outcome

  13. Real-Time and Real-Fast Performance of General-Purpose and Real-Time Operating Systems in Multithreaded Physical Simulation of Complex Mechanical Systems

    Directory of Open Access Journals (Sweden)

    Carlos Garre

    2014-01-01

    Full Text Available Physical simulation is a valuable tool in many fields of engineering for the tasks of design, prototyping, and testing. General-purpose operating systems (GPOS are designed for real-fast tasks, such as offline simulation of complex physical models that should finish as soon as possible. Interfacing hardware at a given rate (as in a hardware-in-the-loop test requires instead maximizing time determinism, for which real-time operating systems (RTOS are designed. In this paper, real-fast and real-time performance of RTOS and GPOS are compared when simulating models of high complexity with large time steps. This type of applications is usually present in the automotive industry and requires a good trade-off between real-fast and real-time performance. The performance of an RTOS and a GPOS is compared by running a tire model scalable on the number of degrees-of-freedom and parallel threads. The benchmark shows that the GPOS present better performance in real-fast runs but worse in real-time due to nonexplicit task switches and to the latency associated with interprocess communication (IPC and task switch.

  14. A comparison of latent class, K-means, and K-median methods for clustering dichotomous data.

    Science.gov (United States)

    Brusco, Michael J; Shireman, Emilie; Steinley, Douglas

    2017-09-01

    The problem of partitioning a collection of objects based on their measurements on a set of dichotomous variables is a well-established problem in psychological research, with applications including clinical diagnosis, educational testing, cognitive categorization, and choice analysis. Latent class analysis and K-means clustering are popular methods for partitioning objects based on dichotomous measures in the psychological literature. The K-median clustering method has recently been touted as a potentially useful tool for psychological data and might be preferable to its close neighbor, K-means, when the variable measures are dichotomous. We conducted simulation-based comparisons of the latent class, K-means, and K-median approaches for partitioning dichotomous data. Although all 3 methods proved capable of recovering cluster structure, K-median clustering yielded the best average performance, followed closely by latent class analysis. We also report results for the 3 methods within the context of an application to transitive reasoning data, in which it was found that the 3 approaches can exhibit profound differences when applied to real data. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  15. Estimation of mean and median pO2 values for a composite EPR spectrum.

    Science.gov (United States)

    Ahmad, Rizwan; Vikram, Deepti S; Potter, Lee C; Kuppusamy, Periannan

    2008-06-01

    Electron paramagnetic resonance (EPR)-based oximetry is capable of quantifying oxygen content in samples. However, for a heterogeneous environment with multiple pO2 values, peak-to-peak linewidth of the composite EPR lineshape does not provide a reliable estimate of the overall pO2 in the sample. The estimate, depending on the heterogeneity, can be severely biased towards narrow components. To address this issue, we suggest a postprocessing method to recover the linewidth histogram which can be used in estimating meaningful parameters, such as the mean and median pO2 values. This information, although not as comprehensive as obtained by EPR spectral-spatial imaging, goes beyond what can be generally achieved with conventional EPR spectroscopy. Substantially shorter acquisition times, in comparison to EPR imaging, may prompt its use in clinically relevant models. For validation, simulation and EPR experiment data are presented.

  16. Real time estimation of photovoltaic modules characteristics and its application to maximum power point operation

    Energy Technology Data Exchange (ETDEWEB)

    Garrigos, Ausias; Blanes, Jose M.; Carrasco, Jose A. [Area de Tecnologia Electronica, Universidad Miguel Hernandez de Elche, Avda. de la Universidad s/n, 03202 Elche, Alicante (Spain); Ejea, Juan B. [Departamento de Ingenieria Electronica, Universidad de Valencia, Avda. Dr Moliner 50, 46100 Valencia, Valencia (Spain)

    2007-05-15

    In this paper, an approximate curve fitting method for photovoltaic modules is presented. The operation is based on solving a simple solar cell electrical model by a microcontroller in real time. Only four voltage and current coordinates are needed to obtain the solar module parameters and set its operation at maximum power in any conditions of illumination and temperature. Despite its simplicity, this method is suitable for low cost real time applications, as control loop reference generator in photovoltaic maximum power point circuits. The theory that supports the estimator together with simulations and experimental results are presented. (author)

  17. Median and common peroneal neuropathy in coir workers of Alappuzha district, Kerala.

    Science.gov (United States)

    Chandra, Sadanandavalli Retnaswami; Anand, Biji; Issac, Thomas Gregor

    2017-01-01

    Coir work, in a large number of people involves mechanically rolling the coconut fibers into coir which is later subjected to various processes. The primary work is done as a cottage industry specially by women in the sitting posture for several hours. This study reports evidence of median and common peroneal neuropathy electrophysiologically in people who had been engaged in this job for several years. This study was initiated to establish the possible relationship between coir work and symptomatic neuropathies which was seen in that region with all investigations " for other causes not " contributing to the etiological diagnosis. One hundred and forty-two upper limbs and 142 lower limbs in patients engaged in long years of coir work but having no symptoms were evaluated electrophysiologically with informed consent and financial compensation, appropriate inclusion and exclusion criteria were followed as described in the text. There is electrophysiological evidence for median and common peroneal neuropathy in persons engaged in long years of coir work. Coir workers neuropathy appears to be a new occupational neuropathy which can be prevented by following simple preventive measures.

  18. Correlation between the median particle size of chewed frankfurter sausage and almonds during masticatory performance test.

    Science.gov (United States)

    Sumonsiri, P; Thongudomporn, U; Paphangkorakit, J

    2018-04-27

    The correlation between chewing and gastric function is best reflected when the same food type is used during both tests. We proposed frankfurter sausage as test food for masticatory performance as it can also be used in gastric emptying test. The suitability of frankfurter sausage to determine masticatory performance, however, has never been examined. To examine the correlations between the median particle size of frankfurter sausage and almonds (as standard test food) after different numbers of chewing cycles. Twenty-seven subjects performed masticatory performance tests by chewing 2 types of test foods, that is, a piece of almond or 5-g frankfurter sausage cubes placed in a sealed latex bag, for 5 and 15 chewing cycles. For each individual, right and left sides were tested separately. Chewed samples obtained from both sides were pooled. Median particle sizes were determined using a multiple sieving method. Spearman's rank correlation was used to examine any correlation between median particle sizes of the 2 test foods after 5 and 15 cycles. Median particle sizes after 5 and 15 cycles were 2.04 ± 0.87 and 0.95 ± 0.58 mm for almonds and 4.16 ± 0.19 and 3.73 ± 0.25 mm for frankfurter sausage, respectively. Significant correlations were observed between the median particle size of chewed frankfurter sausage after 15 cycles and that of chewed almonds after 5 and 15 cycles (r = .76, P < .01 and r = .52, P = .01, respectively). Frankfurter sausage chewed for 15 cycles may be suitable for the determination of masticatory performance in conjunction with gastric emptying test. © 2018 John Wiley & Sons Ltd.

  19. Whither probabilistic security management for real-time operation of power systems ?

    OpenAIRE

    Karangelos, Efthymios; Panciatici, Patrick; Wehenkel, Louis

    2016-01-01

    This paper investigates the stakes of introducing probabilistic approaches for the management of power system’s security. In real-time operation, the aim is to arbitrate in a rational way between preventive and corrective control, while taking into account i) the prior probabilities of contingencies, ii) the possible failure modes of corrective control actions, iii) the socio-economic consequences of service interruptions. This work is a first step towards the construction of a globally co...

  20. A Comparison of Ultrasound and MRI Measurements of the Cross-Sectional Area of the Median Nerve at the Wrist.

    Science.gov (United States)

    Hersh, Beverly; D'Auria, Jennifer; Scott, Michael; Fowler, John R

    2018-05-01

    Ultrasound (US) measurement of cross-sectional area (CSA) of the median nerve has emerged as a viable alternative to electromyography/nerve conduction studies (EMG/NCS) for diagnosis of carpal tunnel syndrome (CTS). The purpose of this study is to compare CSA of the median nerve between US and MRI using current MRI and US technology. The null hypothesis is there is no difference between US and MRI CSA measurements. The study design was an observational cohort, enrolling patients presenting to clinic with MRI of the wrist. Participants with clinical signs and symptoms of CTS were excluded. The CSA measurements of the median nerve on MRI T1-weighted axial images were performed by a hand fellow blinded to results of US measurements, and US measurement of median nerve CSA was performed by a hand fellowship trained surgeon blinded to results of the MRI measurements. Results were analyzed via percent error, Pearson correlation, and t tests. Twenty participants were enrolled with mean age of 29.4 years. Four left wrists and 16 right wrists were measured. The US mean CSA of the median nerve was 6.8 mm 2 (±2.330 mm 2 ). The MRI mean CSA of the median nerve was 6.8 mm 2 (±2.153 mm 2 ), P = .442. Pearson correlation between modalities was 0.93, suggesting near-perfect correlation. Mean percent error was 8.8%. Results of this study suggest that US is an accurate method to measure CSA of the median nerve at the carpal tunnel inlet. The mean difference between US and MRI was unlikely to be clinically significant.

  1. The effect of symptoms of carpal tunnel syndrome on ultrasonographic median nerve measures before and after wheelchair propulsion.

    Science.gov (United States)

    Impink, Bradley G; Collinger, Jennifer L; Boninger, Michael L

    2011-09-01

    To quantify median nerve characteristics before and after strenuous wheelchair propulsion and relate them to symptoms of carpal tunnel syndrome (CTS). We hypothesized that persons with and without symptoms of CTS would have significantly different nerve characteristics at baseline and after propulsion. A repeated-measures design was used to obtain ultrasound images of the median nerve at 3 levels of the wrist (radius, pisiform, and hamate) before and after wheelchair propulsion. Investigators were blinded to subject history related to CTS. The 2007 and 2008 National Veterans Wheelchair Games and the Human Engineering Research Laboratories. Fifty-four participants between the ages of 18 and 65 years with a nonprogressive disability who used a manual wheelchair as their primary means of mobility completed this study. Participants completed questionnaires regarding demographics and the presence and severity of symptoms of CTS. Ultrasound images of the median nerve were obtained before and after a 15-minute strenuous wheelchair-propulsion task. Baseline values and post-propulsion changes were determined for median nerve cross-sectional area, flattening ratio, and swelling ratio. Differences in median nerve variables between symptomatic and asymptomatic groups were assessed. No significant differences between symptom groups were identified at baseline; however, persons with symptoms of CTS showed a significantly different percent change from baseline compared with the asymptomatic participants for cross-sectional area at pisiform (P = .014) and flattening ratio at hamate (P = .022), and they showed a strong trend toward a difference in swelling ratio (P = .0502). For each of these variables, the change in the symptomatic group was in the opposite direction of the change in the asymptomatic group. We found several median nerve responses to wheelchair propulsion associated with symptoms of CTS. These responses occurred even though no baseline ultrasound difference was

  2. Operational definition of (brane-induced) space-time and constraints on the fundamental parameters

    International Nuclear Information System (INIS)

    Maziashvili, Michael

    2008-01-01

    First we contemplate the operational definition of space-time in four dimensions in light of basic principles of quantum mechanics and general relativity and consider some of its phenomenological consequences. The quantum gravitational fluctuations of the background metric that comes through the operational definition of space-time are controlled by the Planck scale and are therefore strongly suppressed. Then we extend our analysis to the braneworld setup with low fundamental scale of gravity. It is observed that in this case the quantum gravitational fluctuations on the brane may become unacceptably large. The magnification of fluctuations is not linked directly to the low quantum gravity scale but rather to the higher-dimensional modification of Newton's inverse square law at relatively large distances. For models with compact extra dimensions the shape modulus of extra space can be used as a most natural and safe stabilization mechanism against these fluctuations

  3. Real time test bed development for power system operation, control and cyber security

    Science.gov (United States)

    Reddi, Ram Mohan

    The operation and control of the power system in an efficient way is important in order to keep the system secure, reliable and economical. With advancements in smart grid, several new algorithms have been developed for improved operation and control. These algorithms need to be extensively tested and validated in real time before applying to the real electric power grid. This work focuses on the development of a real time test bed for testing and validating power system control algorithms, hardware devices and cyber security vulnerability. The test bed developed utilizes several hardware components including relays, phasor measurement units, phasor data concentrator, programmable logic controllers and several software tools. Current work also integrates historian for power system monitoring and data archiving. Finally, two different power system test cases are simulated to demonstrate the applications of developed test bed. The developed test bed can also be used for power system education.

  4. Operation time extension for power units of the first generation NPP and the liability for potential damage

    International Nuclear Information System (INIS)

    Kovalevich, O.M.

    2000-01-01

    The problem on the operation time extension for the six operating NPP first generation power units is discussed. However it is not advisable to improve the safety of these power units up to the acceptable level, therefore there arises the contradiction between the operation time extension of these power units and potential damage for the population. The possibility of having the increased civilian-legal responsibility for potential harm and losses in case of an accident is proposed to be considered as a compensating measure. The measures for realization of this civilian-legal responsibility are described [ru

  5. OceanNOMADS: Real-time and retrospective access to operational U.S. ocean prediction products

    Science.gov (United States)

    Harding, J. M.; Cross, S. L.; Bub, F.; Ji, M.

    2011-12-01

    The National Oceanic and Atmospheric Administration (NOAA) National Operational Model Archive and Distribution System (NOMADS) provides both real-time and archived atmospheric model output from servers at the National Centers for Environmental Prediction (NCEP) and National Climatic Data Center (NCDC) respectively (http://nomads.ncep.noaa.gov/txt_descriptions/marRutledge-1.pdf). The NOAA National Ocean Data Center (NODC) with NCEP is developing a complementary capability called OceanNOMADS for operational ocean prediction models. An NCEP ftp server currently provides real-time ocean forecast output (http://www.opc.ncep.noaa.gov/newNCOM/NCOM_currents.shtml) with retrospective access through NODC. A joint effort between the Northern Gulf Institute (NGI; a NOAA Cooperative Institute) and the NOAA National Coastal Data Development Center (NCDDC; a division of NODC) created the developmental version of the retrospective OceanNOMADS capability (http://www.northerngulfinstitute.org/edac/ocean_nomads.php) under the NGI Ecosystem Data Assembly Center (EDAC) project (http://www.northerngulfinstitute.org/edac/). Complementary funding support for the developmental OceanNOMADS from U.S. Integrated Ocean Observing System (IOOS) through the Southeastern University Research Association (SURA) Model Testbed (http://testbed.sura.org/) this past year provided NODC the analogue that facilitated the creation of an NCDDC production version of OceanNOMADS (http://www.ncddc.noaa.gov/ocean-nomads/). Access tool development and storage of initial archival data sets occur on the NGI/NCDDC developmental servers with transition to NODC/NCCDC production servers as the model archives mature and operational space and distribution capability grow. Navy operational global ocean forecast subsets for U.S waters comprise the initial ocean prediction fields resident on the NCDDC production server. The NGI/NCDDC developmental server currently includes the Naval Research Laboratory Inter-America Seas

  6. Experimental concrete coating application on the median barrier of I 65 in Louisville.

    Science.gov (United States)

    2008-06-01

    The objectives of this research were to evaluate the experimental protective coating that was applied to approximately 1,200 linear feet of concrete median barrier along the paving project on a section of I 65 between mile points 131.289 and 136.421 ...

  7. A two-stage method of quantitative flood risk analysis for reservoir real-time operation using ensemble-based hydrologic forecasts

    Science.gov (United States)

    Liu, P.

    2013-12-01

    Quantitative analysis of the risk for reservoir real-time operation is a hard task owing to the difficulty of accurate description of inflow uncertainties. The ensemble-based hydrologic forecasts directly depict the inflows not only the marginal distributions but also their persistence via scenarios. This motivates us to analyze the reservoir real-time operating risk with ensemble-based hydrologic forecasts as inputs. A method is developed by using the forecast horizon point to divide the future time into two stages, the forecast lead-time and the unpredicted time. The risk within the forecast lead-time is computed based on counting the failure number of forecast scenarios, and the risk in the unpredicted time is estimated using reservoir routing with the design floods and the reservoir water levels of forecast horizon point. As a result, a two-stage risk analysis method is set up to quantify the entire flood risks by defining the ratio of the number of scenarios that excessive the critical value to the total number of scenarios. The China's Three Gorges Reservoir (TGR) is selected as a case study, where the parameter and precipitation uncertainties are implemented to produce ensemble-based hydrologic forecasts. The Bayesian inference, Markov Chain Monte Carlo, is used to account for the parameter uncertainty. Two reservoir operation schemes, the real operated and scenario optimization, are evaluated for the flood risks and hydropower profits analysis. With the 2010 flood, it is found that the improvement of the hydrologic forecast accuracy is unnecessary to decrease the reservoir real-time operation risk, and most risks are from the forecast lead-time. It is therefore valuable to decrease the avarice of ensemble-based hydrologic forecasts with less bias for a reservoir operational purpose.

  8. Comparison of the time taken for localised breast surgery pre- and post-introduction of intra-operative digital specimen mammography.

    Science.gov (United States)

    Carraro do Nascimento, Vinicius; Bourke, Anita G

    2018-02-01

    More than half of the patients with an impalpable malignant breast lesion have a mammographically detected and imaged-guided localisation, which can be technically challenging for the breast surgeon. Specimen imaging is used to confirm successful excision of the localised index lesion and has improved the operating list efficiency resulting in a higher number of excisions per surgical list. The aim of this study was to evaluate whether introducing IDSM (intra-operative digital specimen mammography) saved operation time for localised breast surgery. A single-centre retrospective review was undertaken to compare the operation time (from incision to wound closure) taken for excision of 114 consecutive image-guided localised impalpable breast lesions, performed using departmental specimen radiography (DSR), 6 months prior to the introduction of IDSM (Hologic, Trident ® ) in March 2013, with the theatre time taken for excision of 121 consecutive image-guided localised impalpable breast lesions in the 6 months following introduction of IDSM. There was no significant difference in mean surgical time, which were 47.8 (±27.3) minutes in the CSR group and 48.8 (±25.7) minutes in the IDSM group. We were expecting to confirm a reduction in theatre time with the introduction of IDSM. Surprisingly, no difference in operating times was demonstrated. Factors that influenced the impact of IDSM included the proximity of the imaging department to the operating theatre. © 2017 The Royal Australian and New Zealand College of Radiologists.

  9. Cost per median overall survival month associated with abiraterone acetate and enzalutamide for treatment of patients with metastatic castration-resistant prostate cancer.

    Science.gov (United States)

    Pilon, Dominic; Queener, Marykay; Lefebvre, Patrick; Ellis, Lorie A

    2016-08-01

    To calculate costs per median overall survival (OS) month in chemotherapy-naïve patients with metastatic castration-resistant prostate cancer (mCRPC) treated with abiraterone acetate plus prednisone (AA + P) or enzalutamide. Median treatment duration and median OS data from published Phase 3 clinical trials and prescribing information were used to calculate costs per median OS month based on wholesale acquisition costs (WACs) for patients with mCRPC treated with AA + P or enzalutamide. Sensitivity analyses were performed to understand how variations in treatment duration and treatment-related monitoring recommendations influenced cost per median OS month. Cost-effectiveness estimates of other Phase 3 trial outcomes were also explored: cost per month of chemotherapy avoided and per median radiographic progression-free survival (rPFS) month. The results demonstrated that AA + P has a lower cost per median OS month than enzalutamide ($3231 vs 4512; 28% reduction), based on the following assumptions: median treatment duration of 14 months for AA + P and 18 months for enzalutamide, median OS of 34.7 months for AA + P and 35.3 months for enzalutamide, and WAC per 30-day supply of $8007.17 for AA + P vs $8847.98 for enzalutamide. Sensitivity analyses showed that accounting for recommended treatment-related monitoring costs or assuming identical treatment durations for AA + P and enzalutamide (18 months) resulted in costs per median OS month 8-27% lower for AA + P than for enzalutamide. Costs per month of chemotherapy avoided were $4448 for AA + P and $5688 for enzalutamide, while costs per month to achieve median rPFS were $6794 for AA + P and $7963 for enzalutamide. This cost-effectiveness analysis demonstrated that costs per median OS month, along with costs of other Phase 3 trial outcomes, were lower for AA + P than for enzalutamide. The findings were robust to sensitivity analyses. These results have important implications

  10. Dynamic Value Engineering Method Optimizing the Risk on Real Time Operating System

    Directory of Open Access Journals (Sweden)

    Prashant Kumar Patra

    2014-04-01

    Full Text Available The value engineering is the umbrella of the many more sub-system like quality assurance, quality control, quality function design and development for manufacturability. The system engineering & value engineering is two part of the coin. The value engineering is the high level of technology management for every aspect of engineering fields. The value engineering is the high utilization of System Product (i.e. Processor, Memory & Encryption key, Services, Business and Resources at minimal cost. The high end operating system providing highest services at optimal cost & time. The value engineering provides the maximum performance, accountability, reliability, integrity and availability of processor, memory, encryption key and other inter dependency sub-components. The value engineering is the ratio of the maximum functionality of individual components to the optimal cost. VE=k [(P, M, E, C, A]/optimal cost. Where k is the proportionality constant. The VE is directly proportional to performance of individual components and inversely proportional to the minimal cost. The VE is directly proportional to the risk assessment. The VE maximize the business throughput & decision process mean while minimize the risk and down time. We have to develop the dynamic value engineering model & mechanism for risk optimization over a complex real time operating system This proposed composition model definite will be resolve our objective at top high level. Product

  11. Traumatic First Time Shoulder Dislocation: Surgery vs Non-Operative Treatment

    Directory of Open Access Journals (Sweden)

    Ioannis Polyzois

    2016-04-01

    Full Text Available Management of first shoulder dislocation following reduction remains controversial. The two main options are immobilisation and arthroscopic stabilisation. The aim of this article is to highlight some of the issues that influence decision making when discussing management options with these patients, including natural history of the first time dislocation, outcomes of surgery and non-operative management particularly on the risk of future osteoarthritis (OA, the effects of delaying surgery and the optimal method of immobilisation. Extensive literature review was performed looking for previous publication addressing 4 points. i Natural history of primary shoulder dislocation ii Effect of surgical intervention on natural history iii Risk of long term osteoarthritis with and without surgical intervention iv Immobilisation techniques post reduction. Individuals younger than 25 years old are likely to re-dislocate with non-operative management. Surgery reduces risk of recurrent instability. Patients with recurrent instability appear to be at a higher risk of OA. Those who have surgical stabilisation do not appear to be at a higher risk than those who dislocate just once, but are less likely to develop OA than those with recurrent instability. Delaying surgery makes the stabilisation more demanding due to elongation of capsule, progressive labro-ligamentous injury, prevalence and severity of glenoid bone loss. Recent studies have failed to match the preliminary outcomes associated with external rotation braces. Defining the best timing and type of treatment remains a challenge and should be tailored to each individual’s age, occupation and degree of physical activity.

  12. Operational performance of the TIMED Doppler Interferometer (TIDI)

    Science.gov (United States)

    Skinner, Wilbert R.; Niciejewski, Rick J.; Killeen, Timothy L.; Solomon, Stanley C.; Gablehouse, Daniel; Wu, Qian; Ortland, David; Gell, David A.; Marshall, Alan R.; Wolfe, Edwin, Jr.; Cooper, Marie; Kafkalidis, Julie F.

    2003-11-01

    The TIMED Doppler Interferometer (TIDI) is a Fabry-Perot interferometer designed to measure winds in the mesosphere and thermosphere (60-180 km) as part of the TIMED mission. TIDI is a limb viewer and observes emissions from OI 557.7 nm and rotational lines in the O2(0-0) Atmospheric band. Wind measurement accuracies approach 3 ms-1 in the mesosphere and 15 ms-1 in the thermosphere. The TIDI instrument"s performance during the first year and a half of operation is discussed in this paper. Many subsystems are working as designed. The thermal control system is holding the instrument temperatures at their desired set-points. The CCD detector is working as expected with no changes observed in the gain, bias or read noise. The instrument suffers from a light leak that causes the background to be elevated and increases the uncertainty in the wind measurement. Nothing can be done to eliminate this problem but modeling of the background has eliminated any systematic effect. Water outgassing from the spacecraft or instrument has deposited as ice on some part of the optics and reduced the instrument"s sensitivity. This problem has been reduced by two spacecraft rolls which pointed the TIDI radiator to view more of the earth causing the optics to warm up and sublimate much of the ice.

  13. Anomalous Innervation of the Median Nerve in the Arm in the Absence of the Musculocutaneous Nerve

    Directory of Open Access Journals (Sweden)

    Khursheed Raza

    2017-03-01

    Full Text Available The brachial plexus innervates the upper extremities. While variations in the formation of the brachial plexus and its terminal branches are quite common, it is uncommon for the median nerve to innervate the muscles of the arm. During the dissection of an elderly male cadaver at the Department of Anatomy, All India Institute of Medical Sciences, New Delhi, India, in 2016, the coracobrachialis muscle was found to be supplied by a direct branch from the lateral root of the median nerve and the musculocutaneous nerve was absent. The branches of the median nerve supplied the biceps brachii and brachialis muscles and the last branch continued as the lateral cutaneous nerve of the forearm. These variations may present atypically in cases of arm flexor paralysis or sensory loss on the lateral forearm. Knowledge of these variations is important in surgeries and during the administration of regional anaesthesia near the shoulder joint and upper arm.

  14. Normative weight-adjusted models for the median levels of first trimester serum biomarkers for trisomy 21 screening in a specific ethnicity.

    Directory of Open Access Journals (Sweden)

    Ounjai Kor-Anantakul

    Full Text Available To establish normative weight-adjusted models for the median levels of first trimester serum biomarkers for trisomy 21 screening in southern Thai women, and to compare these reference levels with Caucasian-specific and northern Thai models.A cross-sectional study was conducted in 1,150 normal singleton pregnancy women to determine serum pregnancy-associated plasma protein-A (PAPP-A and free β-human chorionic gonadotropin (β-hCG concentrations in women from southern Thailand. The predicted median values were compared with published equations for Caucasians and northern Thai women.The best-fitting regression equations for the expected median serum levels of PAPP-A (mIU/L and free β- hCG (ng/mL according to maternal weight (Wt in kg and gestational age (GA in days were: [Formula: see text] and [Formula: see text] Both equations were selected with a statistically significant contribution (p< 0.05. Compared with the Caucasian model, the median values of PAPP-A were higher and the median values of free β-hCG were lower in the southern Thai women. And compared with the northern Thai models, the median values of both biomarkers were lower in southern Thai women.The study has successfully developed maternal-weight- and gestational-age-adjusted median normative models to convert the PAPP-A and free β-hCG levels into their Multiple of Median equivalents in southern Thai women. These models confirmed ethnic differences.

  15. Use of real-time tools to support field operations of NSF's Lower Atmosphere Observing Facilities

    Science.gov (United States)

    Daniels, M.; Stossmeister, G.; Johnson, E.; Martin, C.; Webster, C.; Dixon, M.; Maclean, G.

    2012-12-01

    NCAR's Earth Observing Laboratory (EOL) operates Lower Atmosphere Observing Facilities (LAOF) for the scientific community, under sponsorship of the National Science Foundation. In order to obtain the highest quality dataset during field campaigns, real-time decision-making critically depends on the availability of timely data and reliable communications between field operations staff and instrument operators. EOL incorporates the latest technologies to monitor the health of instrumentation, facilitate remote operations of instrumentation and keep project participants abreast of changing conditions in the field. As the availability of bandwidth on mobile communication networks and the capabilities of their associated devices (smart phone, tablets, etc.) improved, so has the ability of researchers to respond to rapidly changing conditions and coordinate ever more detailed measurements from multiple remote fixed, portable and airborne platforms. This presentation will describe several new tools that EOL is making available to project investigators and how these tools are being used in a mobile computing environment to support enhanced data collection during field campaigns. LAOF platforms such as radars, aircraft, sondes, balloons and surface stations all rely on displays of real-time data for their operations. Data from sondes are ingested into the Global Telecommunications System (GTS) for assimilation into regional forecasting models that help guide project operations. Since many of EOL's projects occur around the globe and at the same time instrument complexity has increased, automated monitoring of instrumentation platforms and systems has become essential. Tools are being developed to allow remote instrument control of our suite of observing systems where feasible. The Computing, Data and Software (CDS) Facility of EOL develops and supports a Field Catalog used in field campaigns for nearly two decades. Today, the Field Catalog serves as a hub for the

  16. SOSPO-SP: Secure Operation of Sustainable Power Systems Simulation Platform for Real-Time System State Evaluation and Control

    DEFF Research Database (Denmark)

    Morais, Hugo; Vancraeyveld, Pieter; Pedersen, Allan Henning Birger

    2014-01-01

    Measurement Units (PMUs) provides more information and enables wide-area monitoring with accurate timing. One of the challenges in the near future is converting the high quantity and quality of information provided by PMUs into useful knowledge about operational state of a global system. The use of real-time...... simulation in closed-loop is essential to develop and validate new real-time applications of wide-area PMU data. This paper presents a simulation platform developed within the research project Secure Operation of Sustainable Power Systems (SOSPO). The SOSPO simulation platform (SOSPO-SP) functions...... in a closed-loop, integrating new real-time assessment methods to provide useful information to operators in power system control centers and to develop new control methodologies that handle emergency situations and avoid power system blackouts....

  17. Real-time monitoring and operational control of drinking-water systems

    CERN Document Server

    Ocampo-Martínez, Carlos; Pérez, Ramon; Cembrano, Gabriela; Quevedo, Joseba; Escobet, Teresa

    2017-01-01

    This book presents a set of approaches for the real-time monitoring and control of drinking-water networks based on advanced information and communication technologies. It shows the reader how to achieve significant improvements in efficiency in terms of water use, energy consumption, water loss minimization, and water quality guarantees. The methods and approaches presented are illustrated and have been applied using real-life pilot demonstrations based on the drinking-water network in Barcelona, Spain. The proposed approaches and tools cover: • decision-making support for real-time optimal control of water transport networks, explaining how stochastic model predictive control algorithms that take explicit account of uncertainties associated with energy prices and real demand allow the main flow and pressure actuators—pumping stations and pressure regulation valves—and intermediate storage tanks to be operated to meet demand using the most sustainable types of source and with minimum electricity costs;...

  18. Gender-partitioned patient medians of serum albumin requested by general practitioners for the assessment of analytical stability

    DEFF Research Database (Denmark)

    Hansen, Steen Ingemann; Petersen, Per Hyltoft; Lund, Flemming

    2017-01-01

    BACKGROUND: Recently, the use of separate gender-partitioned patient medians of serum sodium has revealed potential for monitoring analytical stability within the optimum analytical performance specifications for laboratory medicine. The serum albumin concentration depends on whether a patient...... patients were closely related despite considerable variation due to the current analytical variation. This relationship was confirmed by the calculated half-range for the monthly ratio between the genders of 0.44%, which surpasses the optimum analytical performance specification for bias of serum albumin...... (0.72%). The weekly ratio had a half-range of 1.83%, which surpasses the minimum analytical performance specifications of 2.15%. CONCLUSIONS: Monthly gender-partitioned patient medians of serum albumin are useful for monitoring of long-term analytical stability, where the gender medians are two...

  19. Operative intercostal chest drain is not required following extrapleural or transpleural esophageal atresia repair.

    Science.gov (United States)

    Paramalingam, Saravanakumar; Burge, David M; Stanton, Michael P

    2013-08-01

    Approximately half of the United Kingdom patients undergoing esophageal atresia (OA) repair have an operative intercostal chest drain (ICD) placed (2008 British Association of Pediatric Surgeons Congenital Anomalies Surveillance Study data). We reviewed our experience of OA repairs to evaluate if an ICD placement is necessary. Patients with OA/distal tracheoesophageal fistula (TOF), treated between January 1990 and January 2010, were identified by retrospective review of a prospectively maintained electronic database and patient case notes. A total of 112 consecutive patients were identified, of whom 107 were included (73 male). Five were excluded as no case notes were available. Median birth weight was 2,597 g (range 924 to 4,245 g) and median gestational age was 38 weeks (27 to 41 weeks). Median age at discharge was 22 days (3 to 440 days) and median follow-up was 3.5 years (0 to 18 years). Patients were analyzed in two groups-group 1 (n = 73) had an extrapleural (EP) repair, of which 23 had a pleural breach and group 2 (n = 34) had a purposeful transpleural (TP) approach (surgeon preference). Eleven patients (10%) had an operative ICD, of which six patients were in group 1 and five in group 2. These 11 patients had an uncomplicated postoperative course and all operative ICD were removed within 48 hours of surgery. Of the 96 patients that did not have an operative ICD, only 2 (2%) required postoperative intervention. One patient, in group 2, had a postoperative ICD inserted for a simple pneumothorax at 12 hours and removed at 48 hours. The other patient, in group 1, had a clinically detected anastomotic leak after 48 hours and required operative repair. An operative ICD is not required following OA/distal TOF repair, whether the approach is EP or TP. ICD that were electively placed (in 10%) served no clinical purpose. Georg Thieme Verlag KG Stuttgart · New York.

  20. Applications For Real Time NOMADS At NCEP To Disseminate NOAA's Operational Model Data Base

    Science.gov (United States)

    Alpert, J. C.; Wang, J.; Rutledge, G.

    2007-05-01

    A wide range of environmental information, in digital form, with metadata descriptions and supporting infrastructure is contained in the NOAA Operational Modeling Archive Distribution System (NOMADS) and its Real Time (RT) project prototype at the National Centers for Environmental Prediction (NCEP). NOMADS is now delivering on its goal of a seamless framework, from archival to real time data dissemination for NOAA's operational model data holdings. A process is under way to make NOMADS part of NCEP's operational production of products. A goal is to foster collaborations among the research and education communities, value added retailers, and public access for science and development. In the National Research Council's "Completing the Forecast", Recommendation 3.4 states: "NOMADS should be maintained and extended to include (a) long-term archives of the global and regional ensemble forecasting systems at their native resolution, and (b) re-forecast datasets to facilitate post-processing." As one of many participants of NOMADS, NCEP serves the operational model data base using data application protocol (Open-DAP) and other services for participants to serve their data sets and users to obtain them. Using the NCEP global ensemble data as an example, we show an Open-DAP (also known as DODS) client application that provides a request-and-fulfill mechanism for access to the complex ensemble matrix of holdings. As an example of the DAP service, we show a client application which accesses the Global or Regional Ensemble data set to produce user selected weather element event probabilities. The event probabilities are easily extended over model forecast time to show probability histograms defining the future trend of user selected events. This approach insures an efficient use of computer resources because users transmit only the data necessary for their tasks. Data sets are served by OPeN-DAP allowing commercial clients such as MATLAB or IDL as well as freeware clients