WorldWideScience

Sample records for median door-to-balloon time

  1. Improving Door-to-balloon Time by Decreasing Door-to-ECG time for Walk-in STEMI Patients

    Directory of Open Access Journals (Sweden)

    Coyne, Christopher J.

    2014-12-01

    Full Text Available Introduction: The American Heart Association/American College of Cardiology guidelines recommend rapid door-to-electrocardiography (ECG times for patients with ST-segment elevation myocardial infarction (STEMI. Previous quality improvement research at our institution revealed that we were not meeting this benchmark for walk-in STEMI patients. The objective is to investigate whether simple, directed changes in the emergency department (ED triage process for potential cardiac patients could decrease door-to-ECG times and secondarily door-to-balloon times. Methods: We conducted an interventional study at a large, urban, public teaching hospital from April 2010 to June 2012. All patients who walked into the ED with a confirmed STEMI were enrolled in the study. The primary intervention involved creating a chief complaint-based “cardiac triage” designation that streamlined the evaluation of potential cardiac patients. A secondary intervention involved moving our ECG technician and ECG station to our initial triage area. The primary outcome measure was door-to-ECG time and the secondary outcome measure was door-to-balloon time. Results: We enrolled 91 walk-in STEMI patients prior to the intervention period and 141 patients after the invention. We observed statistically significant reductions in door-to-ECG time (43±93 to 30±72 minutes, median 23 to 14 minutes p<0.01, ECG-to-activation time (87±134 to 52±82 minutes, median 43 to 31 minutes p<0.01, and door-to-balloon time (134±146 to 84±40 minutes, median 85 -75 minutes p=0.03. Conclusion: By creating a chief complaint-based cardiac triage protocol and by streamlining ECG completion, walk-in STEMI patients are systematically processed through the ED. This is not only associated with a decrease in door-to-balloon time, but also a decrease in the variability of the time sensitive intervals of door-to-ECG and ECG-to-balloon time. [West J Emerg Med. 2015;16(1:184–189.

  2. Using a Cloud Computing System to Reduce Door-to-Balloon Time in Acute ST-Elevation Myocardial Infarction Patients Transferred for Percutaneous Coronary Intervention.

    Science.gov (United States)

    Ho, Chi-Kung; Chen, Fu-Cheng; Chen, Yung-Lung; Wang, Hui-Ting; Lee, Chien-Ho; Chung, Wen-Jung; Lin, Cheng-Jui; Hsueh, Shu-Kai; Hung, Shin-Chiang; Wu, Kuan-Han; Liu, Chu-Feng; Kung, Chia-Te; Cheng, Cheng-I

    2017-01-01

    This study evaluated the impact on clinical outcomes using a cloud computing system to reduce percutaneous coronary intervention hospital door-to-balloon (DTB) time for ST segment elevation myocardial infarction (STEMI). A total of 369 patients before and after implementation of the transfer protocol were enrolled. Of these patients, 262 were transferred through protocol while the other 107 patients were transferred through the traditional referral process. There were no significant differences in DTB time, pain to door of STEMI receiving center arrival time, and pain to balloon time between the two groups. Pain to electrocardiography time in patients with Killip I/II and catheterization laboratory to balloon time in patients with Killip III/IV were significantly reduced in transferred through protocol group compared to in traditional referral process group (both p cloud computing system in our present protocol did not reduce DTB time.

  3. Using a Cloud Computing System to Reduce Door-to-Balloon Time in Acute ST-Elevation Myocardial Infarction Patients Transferred for Percutaneous Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Chi-Kung Ho

    2017-01-01

    Full Text Available Background. This study evaluated the impact on clinical outcomes using a cloud computing system to reduce percutaneous coronary intervention hospital door-to-balloon (DTB time for ST segment elevation myocardial infarction (STEMI. Methods. A total of 369 patients before and after implementation of the transfer protocol were enrolled. Of these patients, 262 were transferred through protocol while the other 107 patients were transferred through the traditional referral process. Results. There were no significant differences in DTB time, pain to door of STEMI receiving center arrival time, and pain to balloon time between the two groups. Pain to electrocardiography time in patients with Killip I/II and catheterization laboratory to balloon time in patients with Killip III/IV were significantly reduced in transferred through protocol group compared to in traditional referral process group (both p<0.05. There were also no remarkable differences in the complication rate and 30-day mortality between two groups. The multivariate analysis revealed that the independent predictors of 30-day mortality were elderly patients, advanced Killip score, and higher level of troponin-I. Conclusions. This study showed that patients transferred through our present protocol could reduce pain to electrocardiography and catheterization laboratory to balloon time in Killip I/II and III/IV patients separately. However, this study showed that using a cloud computing system in our present protocol did not reduce DTB time.

  4. Impact of around-the-clock in-house cardiology fellow coverage on door-to-balloon time in an academic medical center

    Directory of Open Access Journals (Sweden)

    Kohan LC

    2017-04-01

    Full Text Available Luke C Kohan,1,* Vijaiganesh Nagarajan,1,* Michael A Millard,2 Michael J Loguidice,2 Nancy M Fauber,1 Ellen C Keeley1 1Division of Cardiology, 2Department of Medicine, University of Virginia, Charlottesville, VA, USA * These authors contributed equally to this work Objectives: To assess if a change in our cardiology fellowship program impacted our ST elevation myocardial infarction (STEMI program. Background: Fellows covering the cardiac care unit were spending excessive hours in the hospital while on call, resulting in increased duty hours violations. A night float fellow system was started on July 1, 2012, allowing the cardiac care unit fellow to sign out to a night float fellow at 5:30 pm. The night float fellow remained in-house until the morning. Methods: We performed a retrospective study assessing symptom onset to arrival, arterial access to first device, and door-to-balloon (D2B times, in consecutive STEMI patients presenting to our emergency department before and after initiation of the night float fellow system. Results: From 2009 to 2013, 208 STEMI patients presented to our emergency department and underwent primary percutaneous coronary intervention. There was no difference in symptom onset to arrival (150±102 minutes vs 154±122 minutes, p=0.758, arterial access to first device (12±8 minutes vs 11±7 minutes, p=0.230, or D2B times (50±32 minutes vs 52±34 minutes, p=0.681 during regular working hours. However, there was a significant decrease in D2B times seen during off-hours (72±33 minutes vs 49±15 minutes, p=0.007. There was no difference in in-hospital mortality (11% vs 8%, p=0.484 or need for intra-aortic balloon pump placement (7% vs 8%, p=0.793. Conclusion: In academic medical centers, in-house cardiology fellow coverage during off-hours may expedite care of STEMI patients. Keywords: door-to-balloon time, 24/7 in-house call, cardiology fellow

  5. Financial impact of reducing door-to-balloon time in ST-elevation myocardial infarction: a single hospital experience.

    Science.gov (United States)

    Khot, Umesh N; Johnson-Wood, Michele L; Geddes, Jason B; Ramsey, Curtis; Khot, Monica B; Taillon, Heather; Todd, Randall; Shaikh, Saeed R; Berg, William J

    2009-07-26

    The impact of reducing door-to-balloon time on hospital revenues, costs, and net income is unknown. We prospectively determined the impact on hospital finances of (1) emergency department physician activation of the catheterization lab and (2) immediate transfer of the patient to an immediately available catheterization lab by an in-house transfer team consisting of an emergency department nurse, a critical care unit nurse, and a chest pain unit nurse. We collected financial data for 52 consecutive ST-elevation myocardial infarction patients undergoing emergency percutaneous intervention from October 1, 2004-August 31, 2005 and compared this group to 80 consecutive ST-elevation myocardial infarction patients from September 1, 2005-June 26, 2006 after protocol implementation. Per hospital admission, insurance payments (hospital revenue) decreased ($35,043 +/- $36,670 vs. $25,329 +/- $16,185, P = 0.039) along with total hospital costs ($28,082 +/- $31,453 vs. $18,195 +/- $9,242, P = 0.009). Hospital net income per admission was unchanged ($6962 vs. $7134, P = 0.95) as the drop in hospital revenue equaled the drop in costs. For every $1000 reduction in total hospital costs, insurance payments (hospital revenue) dropped $1077 for private payers and $1199 for Medicare/Medicaid. A decrease in hospital charges ($70,430 +/- $74,033 vs. $53,514 +/- $23,378, P = 0.059), diagnosis related group relative weight (3.7479 +/- 2.6731 vs. 2.9729 +/- 0.8545, P = 0.017) and outlier payments with hospital revenue>$100,000 (7.7% vs. 0%, P = 0.022) all contributed to decreasing ST-elevation myocardial infarction hospitalization revenue. One-year post-discharge financial follow-up revealed similar results: Insurance payments: $49,959 +/- $53,741 vs. $35,937 +/- $23,125, P = 0.044; Total hospital costs: $39,974 +/- $37,434 vs. $26,778 +/- $15,561, P = 0.007; Net Income: $9984 vs. $9159, P = 0.855. All of the financial benefits of reducing door-to-balloon time in ST-elevation myocardial

  6. [Door-to-balloon time and in-hospital mortality in patients with ST-evaluation myocardial infarction: a network experience in a province in northwest Tuscany, Italy].

    Science.gov (United States)

    Paradossi, Umberto; Palmieri, Cataldo; Trianni, Giuseppe; Ravani, Marcello; Vaghetti, Marco; Rizza, Antonio; Gianetti, Jacopo; Cardullo, Simona; Chabane, Hakim; Maffei, Stefano; Berti, Sergio

    2010-05-01

    A network system for ST-elevation myocardial infarction (STEMI) patients offers a quick diagnosis and a rapid transfer to a specialized center for primary percutaneous coronary intervention. The aim of our study was to evaluate the relationship between door-to-balloon time and in-hospital mortality in our network of STEMI patients. Our Hub & Spoke network in the province of Massa-Carrara in the northwest of Tuscany Region, Italy, began in April 2006. This program involved 5 Spoke and 1 Hub centers, 1 medical helicopter, 3 advanced life support ambulances with direct transmission of the ECG and vital parameters to our cath lab on call 24h a day for primary percutaneous coronary intervention. Data regarding clinical, echocardiographic and hemodynamic parameters, the door-to-balloon (DTB) time and their impact on mortality were analyzed. Up to January 2008, 312 STEMI patients were enrolled (242 male, mean age 66.6 +/- 12.3 years). The DTB time was 93 min (79-117, 25th-75th percentile, respectively). The gold standard of a DTB mountain area. Patients from the coast (n = 238) had a DTB time lower than patients from the mountain area (89.5 vs 122.5 min, p < 0.0001), and the risk of in-hospital mortality was significantly and independently correlated with the increase in DTB time (p = 0.04). CONCLUSIONS; Our data confirm the correlation between DTB time and in-hospital mortality. More efforts are necessary to reduce the time to treatment and mortality rates.

  7. Call-to-balloon time dashboard in patients with ST-segment elevation myocardial infarction results in significant improvement in the logistic chain.

    Science.gov (United States)

    Hermans, Maaike P J; Velders, Matthijs A; Smeekes, Martin; Drexhage, Olivier S; Hautvast, Raymond W M; Ytsma, Timon; Schalij, Martin J; Umans, Victor A W M

    2017-08-04

    Timely reperfusion with primary percutaneous coronary intervention (pPCI) in ST-segment elevation myocardial infarction (STEMI) patients is associated with superior clinical outcomes. Aiming to reduce ischaemic time, an innovative system for home-to-hospital (H2H) time monitoring was implemented, which enabled real-time evaluation of ischaemic time intervals, regular feedback and improvements in the logistic chain. The objective of this study was to assess the results after implementation of the H2H dashboard for monitoring and evaluation of ischaemic time in STEMI patients. Ischaemic time in STEMI patients transported by emergency medical services (EMS) and treated with pPCI in the Noordwest Ziekenhuis, Alkmaar before (2008-2009; n=495) and after the implementation of the H2H dashboard (2011-2014; n=441) was compared. Median time intervals were significantly shorter in the H2H group (door-to-balloon time 32 [IQR 25-43] vs. 40 [IQR 28-55] minutes, p-value dashboard was independently associated with shorter time delays. Real-time monitoring and feedback on time delay with the H2H dashboard improves the logistic chain in STEMI patients, resulting in shorter ischaemic time intervals.

  8. Effect of a real-time tele-transmission system of 12-lead electrocardiogram on the first-aid for athletes with ST-elevation myocardial infarction.

    Science.gov (United States)

    Zhang, Huan; Song, Donghan; An, Lina

    2016-05-01

    To study the effect of a real-time tele-transmission system of 12-lead electrocardiogram on door-to-balloon time in athletes with ST-elevation myocardial infarction. A total of 60 athletes with chest pain diagnosed as ST-elevation myocardial infarction (STEMI) from our hospital were randomly divided into group A (n=35) and group B (n=25), the patients in group A transmitted the real-time tele-transmission system of 12-lead electrocardiogram to the chest pain center before arriving in hospital, however, the patients in group B not. The median door-to-balloon time was significant shorter in-group A than group B (38min vs 94 min, p0.05). The median length of stay was significant reduced in-group A (5 days vs 7 days, pelectrocardiogram is beneficial to the pre-hospital diagnosis of STEMI.

  9. Looners: Inside the world of balloon fetishism

    OpenAIRE

    McIntyre, Karen E

    2011-01-01

    In the spring of 1997, Shaun had just broken up with a boyfriend, and his roommate had moved out. Living alone for the first time and relieved of the fear that someone might walk in the door, he was finally able to indulge his fantasy. The young man sat on his couch and started blowing up balloons. Shaun had loved playing with balloons since he was a child. When he hit puberty, he felt his first orgasm rubbing against a balloon. It was then that his relationship with the object took ...

  10. Real-time door detection for indoor autonomous vehicle

    Science.gov (United States)

    He, Zhihao; Zhu, Ming

    2017-07-01

    Indoor Autonomous Vehicle(IAV) is used in many indoor scenes. Such as hotels and hospitals. Door detection is a key issue to guide the IAV into rooms. In this paper, we consider door detection in the use of indoor navigation of IAV. Since real-time properties are important for real-world IAV, the detection algorithm must be fast enough. Most monocular-camera based door detection model need a perfect detection of the four line segments of the door or the four corners. But in many situations, line segments could be extended or cut off. And there could be many false detected corners. And few of them can distinguish doors from door-like objects with door-like shape effectively. We proposed a 2-D vision model of the door that is made up of line segments. The number of parts detected is used to determine the possibility of a door. Our algorithm is tested on a database of doors.1 The robustness and real-time are verified. The precision is 89.4%. Average time consumed for processing a 640x320 figure is 44.73ms.

  11. Evaluation of the door-to-needle time in patients undergoing fibrinolytic therapy after acute myocardial infarction

    International Nuclear Information System (INIS)

    Jehangir, W.; Daood, M.S.; Khan, M.

    2009-01-01

    Early thrombolysis with fibrinolytic therapy has reduced mortality following acute myocardial infarction (AMI) with the major effect coming from early achievement of infarct-related artery potency. This study was carried out to determine the door-to-needle time in patients undergoing fibrinolytic therapy after acute myocardial infarction and to identify factors associated with a prolonged door-to-needle time. This was a cross sectional study in which patients who were thrombolysed for AMI with streptokinase at Punjab Institute of Cardiology, Lahore, from December 12, 2008 to February 18, 2009 were included. All patients admitted with AMI, who were candidates for fibrinolysis, were included. The time of infarction and time of arrival in hospital was determined with ECG changes and asking from patient and/or relatives. The reasons for delay of arrival were asked from patient and accompanying attendants where possible. A door-to-needle time of <30 min could be achieved in 110 of our 201 patients (54.72%). Mean door-to-needle time was 55.13 (+-71.04) minutes. A door-to-needle time of less than 30 minutes in 54.72% is comparable to most contemporary studies however there is a need to look into factors associated with delay. (author)

  12. Door-to-needle time for administration of fibrinolytics in acute ...

    African Journals Online (AJOL)

    Objectives. To determine the current door-to-needle time for the administration of fibrinolytics for acute myocardial infarction (AMI) in emergency centres (ECs) at three hospitals in Cape Town, and to compare it with the American Heart Association/American College of Cardiology (AHA/ACC) recommendation of 30 minutes ...

  13. Time-dependent strains and stresses in a pumpkin balloon

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    This paper presents a study of pumpkin-shaped superpressure balloons consisting of gores made from a thin polymeric film attached to high stiffness meridional tendons This type of design is being used for the NASA ULDB balloons The gore film shows considerable time-dependent stress relaxation whereas the behaviour of the tendons is essentially time-independent Upon inflation and pressurization the instantaneous i e linear-elastic strain and stress distributions in the film show significantly higher values in the meridional direction However over time and due to the biaxial visco-elastic stress relaxation of the the gore material the em hoop strains increase and the em meridional stresses decrease whereas the em remaining strain and stress components remain substantially unchanged These results are important for a correct assessment of the structural integrity of a pumpkin balloon in a long-duration mission both in terms of the material performance and the overall stability of the shape of the balloon An experimental investigation of the time dependence of the biaxial strain distribution in the film of a 4 m diameter 48 gore pumpkin balloon is presented The inflated shape of selected gores has been measured using photogrammetry and the time variation in strain components at some particular points of these gores has been measured under constant pressure and temperature The results show good correlation with a numerical study using the ABAQUS finite-element package that includes a widely used model of

  14. Long-Term Impact of Implementation of a Stroke Protocol on Door-to-Needle Time in the Administration of Intravenous Tissue Plasminogen Activator.

    Science.gov (United States)

    Hillen, Machteld E; He, Wenzhuan; Al-Qudah, Zaid; Wang, Weizhen; Hidalgo, Andrea; Walia, Jessy

    2017-07-01

    This study aims to evaluate the effectiveness of implementing a stroke protocol (SP) in improving door-to-needle time (DTNT) and door-to-computed tomography (DTCT) time from 2010 to 2014. Published data from the Get With The Guidelines-Stroke (GWTGS) participating hospitals showed that median DTNT = 75 minutes with 26.6% of the patients achieving the recommended DTNT of 60 minutes or less. Implementation of an SP, which specifies the role of nurses, physicians, and technicians during acute stroke evaluation, can improve DTNT. This longitudinal quality assurance study was designed to compare the DTNT and the DTCT time pre- and post implementation of an SP in our hospital. Patients' data before (2009-2010) and after (2010-2014) the implementation of an SP were collected each year during the same 6-month period and compared using statistical software SPSS 20.0 for Windows (SPSS Inc., Chicago, IL). Although our DTNT did not significantly improve over the years, the median DTNT (59 minutes) was much less than the reported 75 minutes of GWTGS hospitals. Our DTCT time diminished from 20.6 minutes in 2009 to 15.9 minutes in 2014. The percentage of patients with a DTNT of 1 hour or less did not differ among all years (P = .296) and was 55.8%. Our study suggests that our performance in evaluating acute ischemic stroke patients within the American Heart Association/American Stroke Association suggested time window is reachable for prolonged periods of time. Continuous monitoring and education of all players involved are crucial to ensure best possible outcomes in the timely administration of intravenous tissue plasminogen activator. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  15. Impact of contrast agent viscosity on coronary balloon deflation times: bench testing results.

    Science.gov (United States)

    Mogabgab, Owen; Patel, Vishal G; Michael, Tesfaldet T; Kotsia, Anna; Christopoulos, George; Banerjee, Subhash; Brilakis, Emmanouil S

    2014-04-01

    To assess the impact of viscosity on angioplasty balloon deflation times. Lower contrast viscosity could result in more rapid coronary balloon deflation times. We performed a bench comparison of coronary balloon deflation times using 2 contrast agents with different viscosity (ioxaglate and iodixanol), 3 contrast dilutions, and 2 inflation syringe filling volumes. Ten identical pairs of coronary angioplasty balloons were used to conduct each comparison after balloon inflation to 12 atmospheres. Simultaneous deflations were performed under cineangiography. The time to full contrast extraction and the area of contrast remaining after 5 seconds of deflation (quantified by opaque pixel count) were compared between groups. The mean time to full contrast extraction during balloon deflation was 8.3 ± 2.5 seconds for ioxaglate (lower viscosity) versus 10.1 ± 2.9 seconds for iodixanol (higher viscosity) (17.4% decrease, P = 0.005), with a 35.6% (P = 0.004) reduction in contrast area at 5 seconds. Compared to 1:1 ioxaglate-saline mixture, 1:2 and 1:3 ioxaglate/saline mixes resulted in 26.7% (P deflation time, respectively, but at the expense of decreased balloon opacity. Filling the inflation syringe with 5 versus 15 ml of contrast/saline solution was associated with 7.5% decrease in balloon deflation time (P = 0.005), but no difference in contrast area at 5 seconds (P = 0.749). Use of a lower viscosity contrast agent and higher contrast dilution significantly reduced coronary balloon deflation times, whereas use of lower syringe filling volume had a modest effect. Rapid coronary balloon deflation could improve the safety of interventional procedures. © 2014 Wiley Periodicals, Inc.

  16. Incremental balloon deflation following complete resuscitative endovascular balloon occlusion of the aorta results in steep inflection of flow and rapid reperfusion in a large animal model of hemorrhagic shock.

    Science.gov (United States)

    Davidson, Anders J; Russo, Rachel M; Ferencz, Sarah-Ashley E; Cannon, Jeremy W; Rasmussen, Todd E; Neff, Lucas P; Johnson, M Austin; Williams, Timothy K

    2017-07-01

    To avoid potential cardiovascular collapse after resuscitative endovascular balloon occlusion of the aorta (REBOA), current guidelines recommend methodically deflating the balloon for 5 minutes to gradually reperfuse distal tissue beds. However, anecdotal evidence suggests that this approach may still result in unpredictable aortic flow rates and hemodynamic instability. We sought to characterize aortic flow dynamics following REBOA as the balloon is deflated in accordance with current practice guidelines. Eight Yorkshire-cross swine were splenectomized, instrumented, and subjected to rapid 25% total blood volume hemorrhage. After 30 minutes of shock, animals received 60 minutes of Zone 1 REBOA with a low-profile REBOA catheter. During subsequent resuscitation with shed blood, the aortic occlusion balloon was gradually deflated in stepwise fashion at the rate of 0.5 mL every 30 seconds until completely deflated. Aortic flow rate and proximal mean arterial pressure (MAP) were measured continuously over the period of balloon deflation. Graded balloon deflation resulted in variable initial return of aortic flow (median, 78 seconds; interquartile range [IQR], 68-105 seconds). A rapid increase in aortic flow during a single-balloon deflation step was observed in all animals (median, 819 mL/min; IQR, 664-1241 mL/min) and corresponded with an immediate decrease in proximal MAP (median, 30 mm Hg; IQR, 14.5-37 mm Hg). Total balloon volume and time to return of flow demonstrated no correlation (r = 0.016). This study is the first to characterize aortic flow during balloon deflation following REBOA. A steep inflection point occurs during balloon deflation that results in an abrupt increase in aortic flow and a concomitant decrease in MAP. Furthermore, the onset of distal aortic flow was inconsistent across study animals and did not correlate with initial balloon volume or relative deflation volume. Future studies to define the factors that affect aortic flow during balloon

  17. Prospective multi-centre randomised trial comparing induction of labour with a double-balloon catheter versus dinoprostone

    DEFF Research Database (Denmark)

    Løkkegaard, E; Lundstrøm, M; Kjær, Michael

    2015-01-01

    This randomised controlled study compared the efficacy of double-balloon catheter versus vaginal prostaglandin E2 (dinoprostone) for induction of labour. In total, 825 pregnant women with cephalic presentation and an unfavourable cervix undergoing induction for conventional indications were...... randomised to double-balloon or vaginal dinoprostone (3 mg) groups. There was a significantly higher failure rate for labour induction in the balloon group (relative risk: 1.25, 95% confidence interval [CI]: 1.02-1.49). Median induction time was 27.3 h in the balloon group and 29.8 h in the dinoprostone...

  18. Measuring Quality Improvement in Acute Ischemic Stroke Care: Interrupted Time Series Analysis of Door-to-Needle Time

    Directory of Open Access Journals (Sweden)

    Anne Margreet van Dishoeck

    2014-06-01

    Full Text Available Background: In patients with acute ischemic stroke, early treatment with recombinant tissue plasminogen activator (rtPA improves functional outcome by effectively reducing disability and dependency. Timely thrombolysis, within 1 h, is a vital aspect of acute stroke treatment, and is reflected in the widely used performance indicator ‘door-to-needle time' (DNT. DNT measures the time from the moment the patient enters the emergency department until he/she receives intravenous rtPA. The purpose of the study was to measure quality improvement from the first implementation of thrombolysis in stroke patients in a university hospital in the Netherlands. We further aimed to identify specific interventions that affect DNT. Methods: We included all patients with acute ischemic stroke consecutively admitted to a large university hospital in the Netherlands between January 2006 and December 2012, and focused on those treated with thrombolytic therapy on admission. Data were collected routinely for research purposes and internal quality measurement (the Erasmus Stroke Study. We used a retrospective interrupted time series design to study the trend in DNT, analyzed by means of segmented regression. Results: Between January 2006 and December 2012, 1,703 patients with ischemic stroke were admitted and 262 (17% were treated with rtPA. Patients treated with thrombolysis were on average 63 years old at the time of the stroke and 52% were male. Mean age (p = 0.58 and sex distribution (p = 0.98 did not change over the years. The proportion treated with thrombolysis increased from 5% in 2006 to 22% in 2012. In 2006, none of the patients were treated within 1 h. In 2012, this had increased to 81%. In a logistic regression analysis, this trend was significant (OR 1.6 per year, CI 1.4-1.8. The median DNT was reduced from 75 min in 2006 to 45 min in 2012 (p Conclusion and Implications: The DNT steadily improved from the first implementation of thrombolysis. Specific

  19. Results of a 1-year quality-improvement process to reduce door-to-needle time in acute ischemic stroke with MRI screening.

    Science.gov (United States)

    Sablot, D; Gaillard, N; Colas, C; Smadja, P; Gely, C; Dutray, A; Bonnec, J-M; Jurici, S; Farouil, G; Ferraro-Allou, A; Jantac, M; Allou, T; Pujol, C; Olivier, N; Laverdure, A; Fadat, B; Mas, J; Dumitrana, A; Garcia, Y; Touzani, H; Perucho, P; Moulin, T; Richard, C; Heroum, C; Bouly, S; Sagnes-Raffy, C; Heve, D

    To determine the effects of a 1-year quality-improvement (QI) process to reduce door-to-needle (DTN) time in a secondary general hospital in which multimodal MRI screening is used before tissue plasminogen activator (tPA) administration in patients with acute ischemic stroke (AIS). The QI process was initiated in January 2015. Patients who received intravenous (iv) tPAprocess; the "2015 cohort") were identified (n=130), and their demographic and clinical characteristics and timing metrics compared with those of patients treated by iv tPA in 2014 (the "2014 cohort", n=135). Of the 130 patients in the 2015 cohort, 120 (92.3%) of them were screened by MRI. The median DTN time was significantly reduced by 30% (from 84min in 2014 to 59min; Pimprovement in DTN time was associated with better outcomes after discharge (patients with a 0-2 score on the modified rankin scale: 59% in the 2015 cohort vs 42.4% in the 2014 cohort; Pprocess, the median DTN time decreased by 15% (from 65min in the first trimester to 55min in the last trimester; P≤0.04) with a non-significant 1.5-fold increase in the proportion of treated patients with a DTN time≤60min (from 41% to 62%; P=0.09). It is feasible to deliver tPA to patients with AIS within 60min in a general hospital, using MRI as the routine screening modality, making this QI process to reduce DTN time widely applicable to other secondary general hospitals. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  20. A battery-operated pilot balloon time-signal generator

    Science.gov (United States)

    Ralph H. Moltzau

    1966-01-01

    Describes the design and construction of a 1-pound, battery-operated, time-signal transmitter, which is usable with portable radio or field telephone circuits for synchronizing multi-theodolite observation of pilot balloons.

  1. Evaluation of pre-hospital transport time of stroke patients to thrombolytic treatment.

    Science.gov (United States)

    Simonsen, Sofie Amalie; Andresen, Morten; Michelsen, Lene; Viereck, Søren; Lippert, Freddy K; Iversen, Helle Klingenberg

    2014-11-13

    Effective treatment of stroke is time dependent. Pre-hospital management is an important link in reducing the time from occurrence of stroke symptoms to effective treatment. The aim of this study was to evaluate time used by emergency medical services (EMS) for stroke patients during a five-year period in order to identify potential delays and evaluate the reorganization of EMS in Copenhagen in 2009. We performed a retrospective analysis of ambulance records from stroke patients suitable for thrombolysis from 1 January 2006 to 7 July 2011. We noted response time from dispatch of the ambulance to arrival at the scene, on-scene time and transport time to the hospital-in total, alarm-to-door time. In addition, we noted baseline characteristics. We reviewed 481 records (58% male, median age 66 years). The median (IQR) alarm-to-door time in minutes was 41 (33-52), of which 18 (12-24) minutes were spent on scene. Response time was reduced from the period before to the period after reorganization (7 vs. 5 minutes, p <0.001). In a linear multiple regression model, higher patient age and longer distance to the hospital correlated with significantly longer transportation time (p <0.001). This study shows an unchanged alarm-to-door time of 41 minutes over a five-year period. Response time, but not total alarm-to-door time, was reduced during the five years. On-scene time constituted nearly half of the total alarm-to-door time and is thus a point of focus for improvement.

  2. Field triage reduces treatment delay and improves long-term clinical outcome in patients with acute ST-segment elevation myocardial infarction treated with primary percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Pedersen, Sune H; Galatius, Soren; Hansen, Peter R

    2009-01-01

    by field triage and 821 by emergency departments. Baseline and angiographic variables were similar in the 2 populations. Patients admitted by field triage had a significantly shorter median door-to-balloon time compared with patients admitted by emergency department triage (83 min, interquartile range 67...... to 100 min vs. 103 min, interquartile range 80 to 135 min; p

  3. A review of a regional primary percutaneous coronary intervention service, with a focus on door to reperfusion times: the 2012 Auckland/Northland experience.

    Science.gov (United States)

    Lin, Aaron; Oh, Timothy; Alawami, Mohammed; Webster, Mark; El-Jack, Seif; Scott, Douglas; Stewart, James; Ormiston, John; Armstrong, Guy; Khan, Ali; Kay, Patrick; Harrison, Wil; Kerr, Andrew; McGeorge, Alastair; Gamble, Greg; Ruygrok, Peter; Ellis, Chris J

    2015-01-01

    Primary percutaneous coronary intervention (PCI) is the optimal management for ST segment elevation myocardial infarction (STEMI) patients. We reviewed the largest primary PCI regional service in New Zealand: the Auckland/Northland service based at Auckland City Hospital, to assess patient management, in particular the door to reperfusion times (DTRTs), and predictors of death in hospital. We obtained patient details from a comprehensive prospective database of all primary PCI patients admitted with STEMI from 1/1/12 to 31/12/12 to the Auckland City Hospital cardiac catheterisation laboratory. Of four District Health Boards (DHBs) within the region, two accessed this regional service at all times, and two accessed the Auckland City Hospital cardiac catheterisation laboratory 'after hours': all times except for 08:00 to 16:00 hours on Monday to Friday. A total of 401 adult patients underwent a primary PCI at the Auckland City Hospital Regional centre for a STEMI presentation, over the 12 months period. The median patient age was 61 years, 77% were male. Overall 183 (46%) (95% CI 41, 51) patients achieved a DTRT of Auckland/Northland primary PCI service delivers good outcomes consistent with current Australasian standards. Although geographical isolation complicates door to reperfusion times, these may potentially be improved by more focus on direct transfer to the cardiac catheterisation laboratory, especially directly from the community. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  4. GHOST balloons around Antarctica

    Science.gov (United States)

    Stearns, Charles R.

    1988-01-01

    The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.

  5. A Door-to-Door Combined Transport Planner

    DEFF Research Database (Denmark)

    Aastrup, Jesper; Jespersen, Per Homann; Pedersen, Michael B.

    2004-01-01

    Establishing a web-based portal functioning as a one-stop-shop for transport buyers is a radical idea of a consumer oriented intermodal freight system. This utopian vision will be materialized in a system description and a prototype of a Door-to-Door Combined Trans-port Planner (COTRAP), developed......- and inter-organizational barriers to the establishment of a competitive and effective combined transport system with rail freight operators as the intermodal integrator. In this paper we describes the ideas and methodology behind the project, as well as some preliminary results....

  6. DYNAMIC TIME HISTORY ANALYSIS OF BLAST RESISTANT DOOR USING BLAST LOAD MODELED AS IMPACT LOAD

    Directory of Open Access Journals (Sweden)

    Y. A. Pranata

    2012-06-01

    Full Text Available A blast resistant single door was designed to withstand a 0.91 bar blast pressure and 44 ms blast duration. The analysis was done using Dynamic Time History Analysis using Blast Load modeled as Impact Load for given duration. The material properties used have been modified to accommodate dynamic effects. The analysis was done using dynamic finite element method (fem for time of the blast duration, and the maximum/minimum internal forces and displacement were taken from the time history output, in order to know the behavior under blast load and estimate the safety margin of the door. Results obtained from this research indicated that the maximum z-displacement is 1.709 mm, while in the term of serviceability, the permitted is 25 mm. The maximum reaction force is 73,960 N, while the maximum anchor capacity is 82,069 N. On blast condition, the maximum frame stress is 71.71 MPa, the maximum hinge shear stress is 45.28 MPa. While on rebound condition, the maximum frame stress is 172.11 MPa, the maximum hinge shear stress is 29.46 MPa. The maximum door edge rotation is 0.44 degree, which is not exceed the permitted boundary (1.2 degree. Keywords: Dynamic time history, blast resistant door, single door, finite element method.

  7. Balloon brachytherapy for brain tumor-radiation safety experiences at the University of Medicine and Dentistry of New Jersey.

    Science.gov (United States)

    Lanka, Venkata K

    2006-11-01

    Balloon brachytherapy is a technique for the removal of a brain tumor in which an inflatable balloon is placed in a resection cavity and then filled with liquid I, delivering low energy dose to the cancerous cells surrounding the cavity. After preparing a patient room to mitigate any spills or contamination, liquid 125I (Iotrex) was assayed with a dose calibrator and injected into the balloon placed in the patient's brain. Approximately 98.6% of the isotope was recovered at the end of the procedure. Approximately 1.4% remained unrecovered and is assumed to have diffused through the balloon membrane. Each day, the patient's urine was collected and the total urine activity measured was less than 7% of the unrecovered activity. The remainder of the unrecovered activity was not evaluated. It was assumed to be distributed in the patient's body, and a tiny quantity of liquid spilled from an IV line while injecting. Training was conducted for radiation oncologists, neurosurgeons, and participating residents regarding balloon brachytherapy radiation safety precautions. Precautions during treatment included safe handling of body fluids. General radiation safety precautions and nursing care instructions were posted on the patient door. Air monitoring was conducted to detect any airborne iodine. At the time of balloon removal, the radiation safety department monitored the operating room and staff for contamination. Waste, including the balloon, was held for decay on site prior to disposal.

  8. Comparative study of balloon and metal olive dilators for endoscopic management of benign anastomotic rectal strictures: clinical and cost-effectiveness outcomes.

    Science.gov (United States)

    Xinopoulos, Dimitrios; Kypreos, Dimitrios; Bassioukas, Stefanos P; Korkolis, Dimitrios; Mavridis, Konstantinos; Scorilas, Andreas; Dimitroulopoulos, Dimitrios; Loukou, Argyro; Paraskevas, Emmanouel

    2011-03-01

    Postoperative anastomotic strictures frequently complicate colorectal resection. Currently, various endoscopic techniques are being employed in their management, but the establishment of an optimal therapeutic strategy is still pending. The purpose of our study is to compare through-the-scope (TTS) balloon dilators versus Eder-Puestow metal olive dilators in the treatment of postoperative benign rectal strictures, considering the clinical outcome and cost-effectiveness of each method. A total of 39 patients with benign anastomotic rectal stenosis were retrospectively studied. In group A, 15 patients underwent dilation with Eder-Puestow metal olives, while in group B 19 patients were treated by means of TTS balloon dilators. The technical and clinical success of dilation, complications, number of repeated sessions required, disease-free time intervals, and the overall cost of each procedure were evaluated. Dilations were technically successful in all patients. No major complications occurred in either group. The number of dilations needed, rate of stricture recurrence, and duration of stenosis-free time intervals were not statistically significantly different between the two groups. Both methods proved more effective in older patients, given the greater number of dilations required in younger patients of both groups and higher frequency of stricture relapse in younger balloon-dilated patients (median 64.00 years) compared with older ones (median 75.00 years) (p = 0.001). An indisputable advantage of the Eder-Puestow technique, compared with TTS balloon dilators, is the low cost of equipment (median 22.30 compared with 680 , respectively; p Puestow bougies or TTS balloon dilators. However, metal olivary tips seem to surpass balloon dilators when considering the obvious economical benefits of the first method.

  9. Reducing door-to-needle times using Toyota's lean manufacturing principles and value stream analysis.

    Science.gov (United States)

    Ford, Andria L; Williams, Jennifer A; Spencer, Mary; McCammon, Craig; Khoury, Naim; Sampson, Tomoko R; Panagos, Peter; Lee, Jin-Moo

    2012-12-01

    Earlier tissue-type plasminogen activator (tPA) treatment for acute ischemic stroke increases efficacy, prompting national efforts to reduce door-to-needle times. We used lean process improvement methodology to develop a streamlined intravenous tPA protocol. In early 2011, a multidisciplinary team analyzed the steps required to treat patients with acute ischemic stroke with intravenous tPA using value stream analysis (VSA). We directly compared the tPA-treated patients in the "pre-VSA" epoch with the "post-VSA" epoch with regard to baseline characteristics, protocol metrics, and clinical outcomes. The VSA revealed several tPA protocol inefficiencies: routing of patients to room, then to CT, then back to the room; serial processing of workflow; and delays in waiting for laboratory results. On March 1, 2011, a new protocol incorporated changes to minimize delays: routing patients directly to head CT before the patient room, using parallel process workflow, and implementing point-of-care laboratories. In the pre and post-VSA epochs, 132 and 87 patients were treated with intravenous tPA, respectively. Compared with pre-VSA, door-to-needle times and percent of patients treated ≤60 minutes from hospital arrival were improved in the post-VSA epoch: 60 minutes versus 39 minutes (PLean process improvement methodology can expedite time-dependent stroke care without compromising safety.

  10. Intrarectal pressures and balloon expulsion related to evacuation proctography.

    Science.gov (United States)

    Halligan, S; Thomas, J; Bartram, C

    1995-01-01

    Seventy four patients with constipation were examined by standard evacuation proctography and then attempted to expel a small, non-deformable rectal balloon, connected to a pressure transducer to measure intrarectal pressure. Simultaneous imaging related the intrarectal position of the balloon to rectal deformity. Inability to expel the balloon was associated proctographically with prolonged evacuation, incomplete evacuation, reduced anal canal diameter, and acute anorectal angulation during evacuation. The presence and size of rectocoele or intussusception was unrelated to voiding of paste or balloon. An independent linear combination of pelvic floor descent and evacuation time on proctography correctly predicted maximum intrarectal pressure in 74% of cases. No patient with both prolonged evacuation and reduced pelvic floor descent on proctography could void the balloon, as maximum intrarectal pressure was reduced in this group. A prolonged evacuation time on proctography, in combination with reduced pelvic floor descent, suggests defecatory disorder may be caused by inability to raise intrarectal pressure. A diagnosis of anismus should not be made on proctography solely on the basis of incomplete/prolonged evacuation, as this may simply reflect inadequate straining. PMID:7672656

  11. Iridium: Global OTH data communications for high altitude scientific ballooning

    Science.gov (United States)

    Denney, A.

    While the scientific community is no stranger to embracing commercially available technologies, the growth and availability of truly affordable cutting edge technologies is opening the door to an entirely new means of global communications. For many years high altitude ballooning has provided science an alternative to costly satellite based experimental platforms. As with any project, evolution becomes an integral part of development. Specifically in the NSBF ballooning program, where flight durations have evolved from the earlier days of hours to several weeks and plans are underway to provide missions up to 100 days. Addressing increased flight durations, the harsh operational environment, along with cumbersome and outdated systems used on existing systems, such as the balloon vehicles Support Instrumentation Package (SIP) and ground-based systems, a new Over-The-Horizon (OTH) communications medium is sought. Current OTH equipment planning to be phased-out include: HF commanding systems, ARGOS PTT telemetry downlinks and INMARSAT data terminals. Other aspects up for review in addition to the SIP to utilize this communications medium include pathfinder balloon platforms - thereby, adding commanding abilities and increased data rates, plus providing a package for ultra-small experiments to ride aloft. Existing communication systems employed by the National Scientific Balloon Facility ballooning program have been limited not only by increased cost, slow data rates and "special government use only" services such as TDRSS (Tracking and Data Relay Satellite System), but have had to make special provisions to geographical flight location. Development of the Support Instrumentation Packages whether LDB (Long Duration Balloon), ULDB (Ultra Long Duration Balloon) or conventional ballooning have been plagued by non-standard systems configurations requiring additional support equipment for different regions and missions along with a myriad of backup for redundancy. Several

  12. A method for sampling microbial aerosols using high altitude balloons.

    Science.gov (United States)

    Bryan, N C; Stewart, M; Granger, D; Guzik, T G; Christner, B C

    2014-12-01

    Owing to the challenges posed to microbial aerosol sampling at high altitudes, very little is known about the abundance, diversity, and extent of microbial taxa in the Earth-atmosphere system. To directly address this knowledge gap, we designed, constructed, and tested a system that passively samples aerosols during ascent through the atmosphere while tethered to a helium-filled latex sounding balloon. The sampling payload is ~ 2.7 kg and comprised of an electronics box and three sampling chambers (one serving as a procedural control). Each chamber is sealed with retractable doors that can be commanded to open and close at designated altitudes. The payload is deployed together with radio beacons that transmit GPS coordinates (latitude, longitude and altitude) in real time for tracking and recovery. A cut mechanism separates the payload string from the balloon at any desired altitude, returning all equipment safely to the ground on a parachute. When the chambers are opened, aerosol sampling is performed using the Rotorod® collection method (40 rods per chamber), with each rod passing through 0.035 m3 per km of altitude sampled. Based on quality control measurements, the collection of ~ 100 cells rod(-1) provided a 3-sigma confidence level of detection. The payload system described can be mated with any type of balloon platform and provides a tool for characterizing the vertical distribution of microorganisms in the troposphere and stratosphere. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Balloon dilatation of the prostatic urethra

    International Nuclear Information System (INIS)

    Lee, Yeon Soo; Shim, Hyung Jin; Cha, Kyung Soo; Hong, Ju Hee; Lim, Myung Ah; Kim, Cheol Soo

    1991-01-01

    We analyzed the result of transurethral balloon dilatation in 11 patients with benign prostatic hypertrophy. The procedures were performed under intravenous sedation and local anesthesia with double lumen balloon catheter at 4 atmosphere for 10 minutes. After dilatation, the prostatism symptom scores improved in 10 out of 11 patients and the mean diameter of the prostatic urethra significantly increased form 4.3 mm to 10.2 mm (ρ < 0.005). The procedures were successful not only in lateral lobe hypertrophy but also in median lobe hypertrophy of the prostate. Postdilatation MRI of 1 patient showed an intact prostatic capsule and no periprostatic hematoma. Complications did not develop except in 1 patient with mild hematuria and incontinence. These preliminary results suggest that transurethral balloon dilatation can be an effective and safe treatment modality for benign prostatic hypertrophy

  14. CT and MRI-based door-needle-times for acute stroke patients a quasi-randomized clinical trial

    DEFF Research Database (Denmark)

    Hansen, Christine Krarup; Christensen, Anders; Rodgers, Helen

    2017-01-01

    OBJECTIVES: Door-Needle-times (DNT) of 20min are feasible when Computer Tomography (CT) is used for first-line brain-imaging to assess stroke-patients' eligibility for intravenous-tissue-Plasminogen-Activator (iv-tPA), but the more time-consuming Magnetic Resonance Imaging (MRI)-based-evaluation ......OBJECTIVES: Door-Needle-times (DNT) of 20min are feasible when Computer Tomography (CT) is used for first-line brain-imaging to assess stroke-patients' eligibility for intravenous-tissue-Plasminogen-Activator (iv-tPA), but the more time-consuming Magnetic Resonance Imaging (MRI...

  15. Electric two wheelers, zero emission solution for urban door to door transportation

    DEFF Research Database (Denmark)

    Fasil, Muhammed; Jensen, Bogi Bech

    The noise and exhaust pollution coupled with increasing congestion faced by urban centres demands new personal mobility solution for faster door to door connectivity. The advancement in electric power train and lowering cost of Li-ion battery is made it possible to develop light weight fully...

  16. The use of a prospective audit proforma to improve door-to-mask times for acute exacerbations chronic obstructive pulmonary disease (COPD) requiring non-invasive ventilation (NIV).

    Science.gov (United States)

    Mandal, S; Howes, T Q; Parker, M; Roberts, C M

    2014-12-01

    Non-invasive ventilation (NIV) is an evidence based management of acidotic, hypercapnic exacerbations of COPD. Previous national and international audits of clinical practice have shown variation against guideline standards with significant delays in initiating NIV. We aimed to map the clinical pathway to better understand delays and reduce the door-to-NIV time to less than 3 hours for all patients with acidotic, hypercapnic exacerbations of COPD requiring this intervention, by mandating the use of a guideline based educational management proforma.The proforma was introduced at 7 acute hospitals in North London and Essex and initiated at admission of the patient. It was used to record the clinical pathway and patient outcomes until the point of discharge or death. Data for 138 patients were collected. 48% of patients commenced NIV within 3 hours with no reduction in door-to-mask time during the study period. Delays in starting NIV were due to: time taken for review by the medical team (101 minutes) and time taken for NIV to be started once a decision had been made (49 minutes). There were significant differences in door-to-NIV decision and mask times between differing respiratory on-call systems, p < 0.05). The introduction of the proforma had no effect on door-to-mask times over the study period. Main reasons for delay were related to timely access to medical staff and to NIV equipment; however, a marked variation in practice within these hospitals was been noted, with a 9-5 respiratory on-call system associated with shorter NIV initiation times.

  17. Direct Observation of Long-Range Transport Using Continuously Sounding Balloons and Near-Real-Time Trajectory Modeling

    Science.gov (United States)

    Voss, P. B.; Zaveri, R. A.; Berkowitz, C. M.

    2009-12-01

    Controlled Meteorological (CMET) balloons have been used in several recent studies to measure long-range transport over periods as long as 30 hours and distances up to 1000 kilometers. By repeatedly performing shallow soundings as they drift, CMET balloons can quantify evolving atmospheric structure, mixing events, shear advection, and dispersion during transport. In addition, the quasi-Lagrangian wind profiles can be used to drive a multi-layer trajectory model in which the advected air parcels follow the underlying terrain, or are constrained by altitude, potential temperature, or tracer concentration. Data from a coordinated balloon-aircraft study of long range transport over Texas (SETTS 2005) show that the reconstructed trajectories accurately track residual-layer urban outflow (and at times even its fine-scale structure) over distances of many hundreds of kilometers. The reconstructed trajectories and evolving profile visualizations are increasingly being made available in near-real time during balloon flights, supporting data-driven flight planning and sophisticated process studies relevant to atmospheric chemistry and climate. Multilayer trajectories (black grids) derived from CMET balloon flight paths (grey lines) for a transport event across Texas in 2005.

  18. Influence of Contrast Agent Dilution on Ballon Deflation Time and Visibility During Tracheal Balloon Dilation: A 3D Printed Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Tae; Park, Jung-Hoon; Shin, Ji Hoon, E-mail: jhshin@amc.seoul.kr; Kim, Namkug, E-mail: namkugkim@gmail.com [University of Ulsan College of Medicine, Departments of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of); Kim, Sunghyun Daniel [Seoul National University College of Medicine (Korea, Republic of); Tsauo, Jiaywei; Kim, Kun Young [University of Ulsan College of Medicine, Departments of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of); Kim, Guk Bae [University of Ulsan College of Medicine, Biomedical Engineering Research Center, Asan Medical Center (Korea, Republic of); Song, Ho-Young [University of Ulsan College of Medicine, Departments of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of)

    2017-02-15

    PurposeTo determine the effect of contrast medium dilution during tracheal balloon dilation on balloon deflation time and visibility using a 3-dimensional (3D) printed airway phantom.Materials and MethodsA comparison study to investigate balloon deflation times and image quality was performed using two contrast agents with different viscosities, i.e., iohexol and ioxithalamate, and six contrast dilutions with a 3D printed airway phantom.ResultsCompared to 1:0 concentration, 3:1, 2:1, 1:1, 1:2, and 1:3, contrast/saline ratios resulted in a 46% (56.2 s), 59.8% (73.1 s), 74.9% (91.6 s), 81.7% (99.8 s), and 83.5% (102 s) reduction for iohexol, respectively, and a 51.8% (54.7 s), 63.8% (67.6 s), 74.7% (79.2 s), 80.5% (85.3 s), and 82.4% (87.4 s) reduction for ioxithalamate, respectively, in the mean balloon deflation time, although at the expense of decreased balloon opacity (3.5, 6.9, 11.1, 12.4, and 13.9%, for iohexol, respectively, and 3.2, 6, 9.6, 10.8, and 12.4%, for ioxithalamate, respectively).ConclusionsUse of a lower viscosity contrast agent and higher contrast dilution is considered to be able to reduce balloon deflation times and then simultaneously decrease visualization of balloons. The rapid balloon deflation time is likely to improve the safe performance of interventional procedures.

  19. Influence of Contrast Agent Dilution on Ballon Deflation Time and Visibility During Tracheal Balloon Dilation: A 3D Printed Phantom Study.

    Science.gov (United States)

    Kim, Min Tae; Park, Jung-Hoon; Shin, Ji Hoon; Kim, Namkug; Kim, Sunghyun Daniel; Tsauo, Jiaywei; Kim, Kun Young; Kim, Guk Bae; Song, Ho-Young

    2017-02-01

    To determine the effect of contrast medium dilution during tracheal balloon dilation on balloon deflation time and visibility using a 3-dimensional (3D) printed airway phantom. A comparison study to investigate balloon deflation times and image quality was performed using two contrast agents with different viscosities, i.e., iohexol and ioxithalamate, and six contrast dilutions with a 3D printed airway phantom. Compared to 1:0 concentration, 3:1, 2:1, 1:1, 1:2, and 1:3, contrast/saline ratios resulted in a 46% (56.2 s), 59.8% (73.1 s), 74.9% (91.6 s), 81.7% (99.8 s), and 83.5% (102 s) reduction for iohexol, respectively, and a 51.8% (54.7 s), 63.8% (67.6 s), 74.7% (79.2 s), 80.5% (85.3 s), and 82.4% (87.4 s) reduction for ioxithalamate, respectively, in the mean balloon deflation time, although at the expense of decreased balloon opacity (3.5, 6.9, 11.1, 12.4, and 13.9%, for iohexol, respectively, and 3.2, 6, 9.6, 10.8, and 12.4%, for ioxithalamate, respectively). Use of a lower viscosity contrast agent and higher contrast dilution is considered to be able to reduce balloon deflation times and then simultaneously decrease visualization of balloons. The rapid balloon deflation time is likely to improve the safe performance of interventional procedures.

  20. Influence of Contrast Agent Dilution on Ballon Deflation Time and Visibility During Tracheal Balloon Dilation: A 3D Printed Phantom Study

    International Nuclear Information System (INIS)

    Kim, Min Tae; Park, Jung-Hoon; Shin, Ji Hoon; Kim, Namkug; Kim, Sunghyun Daniel; Tsauo, Jiaywei; Kim, Kun Young; Kim, Guk Bae; Song, Ho-Young

    2017-01-01

    PurposeTo determine the effect of contrast medium dilution during tracheal balloon dilation on balloon deflation time and visibility using a 3-dimensional (3D) printed airway phantom.Materials and MethodsA comparison study to investigate balloon deflation times and image quality was performed using two contrast agents with different viscosities, i.e., iohexol and ioxithalamate, and six contrast dilutions with a 3D printed airway phantom.ResultsCompared to 1:0 concentration, 3:1, 2:1, 1:1, 1:2, and 1:3, contrast/saline ratios resulted in a 46% (56.2 s), 59.8% (73.1 s), 74.9% (91.6 s), 81.7% (99.8 s), and 83.5% (102 s) reduction for iohexol, respectively, and a 51.8% (54.7 s), 63.8% (67.6 s), 74.7% (79.2 s), 80.5% (85.3 s), and 82.4% (87.4 s) reduction for ioxithalamate, respectively, in the mean balloon deflation time, although at the expense of decreased balloon opacity (3.5, 6.9, 11.1, 12.4, and 13.9%, for iohexol, respectively, and 3.2, 6, 9.6, 10.8, and 12.4%, for ioxithalamate, respectively).ConclusionsUse of a lower viscosity contrast agent and higher contrast dilution is considered to be able to reduce balloon deflation times and then simultaneously decrease visualization of balloons. The rapid balloon deflation time is likely to improve the safe performance of interventional procedures.

  1. Balloon dilatation of the esophageal stricture in infants and children

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Sung Wook; Kim, In One; Kim, Woo Sun; Yeon, Kyung Mo; Kim, Woo Ki; Park, Kwi Won; Han, Man Chung [Seoul Natioal University College of Medicine, Seoul (Korea, Republic of); Lee, Gi Jae [Inje University Paik Hospital, Seoul (Korea, Republic of); Yu, Pil Mun [Dankuk University College of Medicine, Seoul (Korea, Republic of)

    1992-09-15

    Balloon dilatation has been applied in treating of various pathologic narrowing of the hollow viscus. It is now accepted as a very effective modality especially in treating esophageal stenosis obviating surgical procedure. We performed 128 balloon dilatations in 29 patients with the number of dilatations in each patient ranging from once to 12 times. The age distribution of the patients was from 3 weeks to 6 years, with the median age of 3 months. Twenty nine patients consisted of 25 postoperative esophageal strictures (21 esophageal atresia with tracheoesophageal fistula, 1 congenital esophageal stenosis, 2 tracheobronchial remnant, and 1 congenital esophageal stenosis with esophageal atresia), 2 achalasia, 1 congenital esophageal stenosis, and 1 corrosive esophagitis. We had successful dilatation in 22 patients, who showed subsequent relief of symptoms and improvement in the diameter of stenotic segment. In 14 patients, esophageal perforation occurred during the procedure, one requiring emergency thoracotomy and the other three conservative management. Seven patients had no improvement in stenotic sites after several balloon dilatations. Failed cases were congenital stenosis, achalasia, corrosive esophagitis and four postoperative strictures. We believe that balloon dilatation is the procedure of choice in the treatment of postoperative esophageal stricture in infants and children and is a safe method as the perforation which can complicate the procedure could be managed conservatively.

  2. Balloon dilatation of the esophageal stricture in infants and children

    International Nuclear Information System (INIS)

    Choo, Sung Wook; Kim, In One; Kim, Woo Sun; Yeon, Kyung Mo; Kim, Woo Ki; Park, Kwi Won; Han, Man Chung; Lee, Gi Jae; Yu, Pil Mun

    1992-01-01

    Balloon dilatation has been applied in treating of various pathologic narrowing of the hollow viscus. It is now accepted as a very effective modality especially in treating esophageal stenosis obviating surgical procedure. We performed 128 balloon dilatations in 29 patients with the number of dilatations in each patient ranging from once to 12 times. The age distribution of the patients was from 3 weeks to 6 years, with the median age of 3 months. Twenty nine patients consisted of 25 postoperative esophageal strictures (21 esophageal atresia with tracheoesophageal fistula, 1 congenital esophageal stenosis, 2 tracheobronchial remnant, and 1 congenital esophageal stenosis with esophageal atresia), 2 achalasia, 1 congenital esophageal stenosis, and 1 corrosive esophagitis. We had successful dilatation in 22 patients, who showed subsequent relief of symptoms and improvement in the diameter of stenotic segment. In 14 patients, esophageal perforation occurred during the procedure, one requiring emergency thoracotomy and the other three conservative management. Seven patients had no improvement in stenotic sites after several balloon dilatations. Failed cases were congenital stenosis, achalasia, corrosive esophagitis and four postoperative strictures. We believe that balloon dilatation is the procedure of choice in the treatment of postoperative esophageal stricture in infants and children and is a safe method as the perforation which can complicate the procedure could be managed conservatively

  3. Clinical application of Inoue-balloon in percutaneous transluminal angioplasty for Budd-Chiari syndrome

    International Nuclear Information System (INIS)

    Mei Jian; Qu Jian; Zhu Yaoqing; Wang Lei; Liu Cheng

    2007-01-01

    Objective: To investigate the feasibility and effect of recanalization of inferior vena cava with percutaneous transluminal angioplasty(PTA)by Inoue-balloon. Methods: Eighty-nine patients with Budd-chiari syndrome (BCS )were treated with PTA by Inoue-balloon. Results: After PTA, the median (interquartile range)diameter of hepatic segment inferior vena cava increased from 0.00 (0.20-0.00) cm to 1.90 (2.00 1.47)cm; (P < 0.001), and the mean pressure of inferior vena cava reduced from (20.63 ± 7.22) mmHg to (12.13 ± 5.60) mmHg; (P < 0.001); with only less serious complications as rupture in two cases and without need of prior minor diameter balloon dilation in Inoue-balloon PTA. Conclusion: The advantages of Inoue- balloon PTA for BCS are more reliable and facile than those of polyethylene balloon, and may take the place in the foreseen future. (authors)

  4. Covered Balloon-Expanding Stents in Airway Stenosis.

    Science.gov (United States)

    Majid, Adnan; Kheir, Fayez; Chung, Jey; Alape, Daniel; Husta, Bryan; Oh, Scott; Folch, Erik

    2017-04-01

    The balloon-expanding stents are widely available but rarely described for use within the tracheobronchial tree. This report describes our experience with these stents in airway stenosis particularly as a lobar salvage therapy. This was a retrospective review of all records in which the balloon-expanding stents were used at a tertiary medical center. Ages, sex, location of stenosis, etiology of stenosis, stent size, duration of stent placement and associated interventions for airway stenosis were recorded. Patient's self-reported respiratory symptoms, dyspnea scale, and radiographic imaging at baseline and after stent placement were also reported. Twenty-one Atrium iCAST stents were inserted in 18 patients with malignant and benign airway disease. The median age was 69.5 years (interquartile range, 53.5 to 74). Most stents (n=20, 95%) were deployed in the lobar airways. There was a significant improvement in the modified Medical Research Council dyspnea scale from median of 3 to 2 (Pstent placement was achieved in 15 patients (83%). No deaths were related to airway stenting complications. Adverse events related to stents included migration (n=2, 9.5%), granulation tissue formation (n=2, 9.5%) and mucus plugging (n=1, 4.8%). Lobar stenting with balloon-expanding metallic stents appears feasible, safe and improves symptoms as well as radiographic atelectasis in patients with lobar airway stenosis in this small case series. Larger studies are needed to confirm this observation and to address long-term safety.

  5. Management and complications of anaesthesia during balloon valvuloplasty for pulmonic stenosis in dogs: 39 cases (2000 to 2012).

    Science.gov (United States)

    Ramos, R V; Monteiro-Steagall, B P; Steagall, P V M

    2014-04-01

    The aim of this study was to report the management and complications of anaesthesia in dogs undergoing balloon valvuloplasty. A retrospective review of medical records of dogs that were diagnosed with pulmonic stenosis and undergoing balloon valvuloplasty between 2000 and 2012. Thirty-nine cases were identified (28 males and 11 females). Median (range) age and bodyweight was 6 (4 to 48) months and 11·5 (2·0 to 30·3) kg, respectively. The most commonly represented breeds included mixed breed (n = 7, 17·9%) and English bulldog (n = 6, 15·3%). Anaesthesia was induced most commonly with intravenous administration of ketamine-diazepam (n = 8, 20·5%), propofol-diazepam (n = 8, 20·5%), or propofol-midazolam-lidocaine (n = 6, 15·4%), and maintained with isoflurane in combination with fentanyl or lidocaine. Anaesthetic and surgery times (mean ± sd) were 268·5 ±54 minutes and 193·2 ±50 minutes, respectively. The most common intraoperative complications were hypotension (n = 19, 48·7%), bradycardia (n = 8, 20·5%) and desaturation (n = 7, 17·9%). Cardiac arrhythmias were observed in 21 (53·8%) dogs. Death occurred in one (2·6%) dog due to severe hypotension after ballooning followed by cardiac arrest. Successful anaesthesia can be performed in young dogs with pulmonic stenosis undergoing balloon valvuloplasty. Management of anaesthesia requires intense monitoring and immediate treatment of complications. Anaesthetic risk increases during ballooning and may result in cardiac arrest. © 2014 British Small Animal Veterinary Association.

  6. The Vaccination of 35,000 Dogs in 20 Working Days Using Combined Static Point and Door-to-Door Methods in Blantyre, Malawi.

    Directory of Open Access Journals (Sweden)

    Andrew D Gibson

    2016-07-01

    Full Text Available An estimated 60,000 people die of rabies annually. The vast majority of cases of human rabies develop following a bite from an infected dog. Rabies can be controlled in both human and canine populations through widespread vaccination of dogs. Rabies is particularly problematic in Malawi, costing the country an estimated 13 million USD and 484 human deaths annually, with an increasing paediatric incidence in Blantyre City. Consequently, the aim of this study was to vaccinate a minimum of 75% of all the dogs within Blantyre city during a one month period. Blantyre's 25 administrative wards were divided into 204 working zones. For initial planning, a mean human:dog ratio from the literature enabled estimation of dog population size and dog surveys were then performed in 29 working zones in order to assess dog distribution by land type. Vaccination was conducted at static point stations at weekends, at a total of 44 sites, with each operating for an average of 1.3 days. On Monday to Wednesday, door-to-door vaccination sessions were undertaken in the areas surrounding the preceding static point stations. 23,442 dogs were vaccinated at static point stations and 11,774 dogs were vaccinated during door-to-door vaccinations. At the end of the 20 day vaccination programme, an assessment of vaccination coverage through door-to-door surveys found that of 10,919 dogs observed, 8,661 were vaccinated resulting in a vaccination coverage of 79.3% (95%CI 78.6-80.1%. The estimated human:dog ratio for Blantyre city was 18.1:1. Mobile technology facilitated the collection of data as well as efficient direction and coordination of vaccination teams in near real time. This study demonstrates the feasibility of vaccinating large numbers of dogs at a high vaccination coverage, over a short time period in a large African city.

  7. The Vaccination of 35,000 Dogs in 20 Working Days Using Combined Static Point and Door-to-Door Methods in Blantyre, Malawi.

    Science.gov (United States)

    Gibson, Andrew D; Handel, Ian G; Shervell, Kate; Roux, Tarryn; Mayer, Dagmar; Muyila, Stanford; Maruwo, Golden B; Nkhulungo, Edwin M S; Foster, Rachel A; Chikungwa, Patrick; Chimera, Bernard; Bronsvoort, Barend M deC; Mellanby, Richard J; Gamble, Luke

    2016-07-01

    An estimated 60,000 people die of rabies annually. The vast majority of cases of human rabies develop following a bite from an infected dog. Rabies can be controlled in both human and canine populations through widespread vaccination of dogs. Rabies is particularly problematic in Malawi, costing the country an estimated 13 million USD and 484 human deaths annually, with an increasing paediatric incidence in Blantyre City. Consequently, the aim of this study was to vaccinate a minimum of 75% of all the dogs within Blantyre city during a one month period. Blantyre's 25 administrative wards were divided into 204 working zones. For initial planning, a mean human:dog ratio from the literature enabled estimation of dog population size and dog surveys were then performed in 29 working zones in order to assess dog distribution by land type. Vaccination was conducted at static point stations at weekends, at a total of 44 sites, with each operating for an average of 1.3 days. On Monday to Wednesday, door-to-door vaccination sessions were undertaken in the areas surrounding the preceding static point stations. 23,442 dogs were vaccinated at static point stations and 11,774 dogs were vaccinated during door-to-door vaccinations. At the end of the 20 day vaccination programme, an assessment of vaccination coverage through door-to-door surveys found that of 10,919 dogs observed, 8,661 were vaccinated resulting in a vaccination coverage of 79.3% (95%CI 78.6-80.1%). The estimated human:dog ratio for Blantyre city was 18.1:1. Mobile technology facilitated the collection of data as well as efficient direction and coordination of vaccination teams in near real time. This study demonstrates the feasibility of vaccinating large numbers of dogs at a high vaccination coverage, over a short time period in a large African city.

  8. Windows and doors

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    A complete manual is presented on windows and doors for the housing contractor. In order to understand the role of windows and doors in a house's energy performance, an introduction explains the house as a system of components that can have effects on each other. Further chapters explain in detail the parts of a window, window types and RSI values; window servicing and repair; window replacement; parts of a door, door types and RSI values; door service and repair, including weatherstripping; door replacement; and how to ensure quality, service, and customer satisfaction. A glossary of terms is included. 61 figs., 3 tabs.

  9. Reduction of the door-to-needle time for administration of antibiotics in patients with a severe infection: a tailored intervention project

    NARCIS (Netherlands)

    van Tuijn, C. F. J.; Luitse, J. S.; van der Valk, M.; van Wissen, S.; Prins, M. [= Maria; Rosmulder, R.; Geerlings, S. E.

    2010-01-01

    Background: Door-to-needle time (DNT), defined as the time between arrival at the emergency department (ED) and intravenous (iv) antibiotic administration is of crucial importance in the treatment of patients suffering from serious infections. The aim of this project was to reduce the DNT for

  10. Stimulus-response time to alarms of the intra-aortic balloon pump: safe care practices

    Directory of Open Access Journals (Sweden)

    Andrezza Serpa Franco

    Full Text Available ABSTRACT Objective: To characterize the sound alarms of the Intra-Aortic Balloon Pump (IABP during aortic counterpulsation therapy; to measure the stimulus-response time of the team to these; and to discuss the implications of increasing this time for patient safety from the alarm fatigue perspective. Method: This is an observational and descriptive study with quantitative and qualitative approach, case study type, carried out in a Cardiac Surgical Intensive Care Unit. Results: The most audible IABP alarm was the one of high priority increased-reduced diastolic blood pressure. The stimulus-response time was 33.9 seconds on average. Conclusion: Managing the alarms of these equipment is essential to minimize the occurrence of the alarm fatigue phenomenon and to offer a safer assistance to patients who rely on this technology.

  11. Two Tethered Balloon Systems

    Science.gov (United States)

    Youngbluth, Otto; Owens, Thomas L.; Storey, Richard W.

    1990-01-01

    Systems take meteorological measurements for variety of research projects. Report describes work done by NASA Langley Research Center in atmospheric research using tethered balloon systems composed of commercially available equipment. Two separate tethered balloon systems described in report have payloads and configurations tailored to requirements of specific projects. Each system capable of measuring atmospheric parameter or species in situ and then telemetering this data in real time to ground station. Meteorological data and concentration of ozone typically measured. Indicates instrumented tethered balloon systems have distinct advantages over other systems for gathering data on troposphere.

  12. Holiday Door Decorating Contest Brings Cheer | Poster

    Science.gov (United States)

    By Carolynne Keenan, Contributing Writer Other than the time of year, what do the following have in common: the leg lamp from the movie “A Christmas Story,” a compilation of silly holiday jokes, a gingerbread house, and Santa on a motorcycle? All four were among the individual door winners for the Holiday Door Decorating Contest, held at NCI at Frederick in December. Employees dressed up their office doors, hallways, and even stairwells to participate. Entries for the contest included individual office doors as well as groups. Some employees even “decked the halls” of whole office buildings to participate.

  13. Simultaneous stent expansion/balloon deflation technique to salvage failed balloon remodeling.

    Science.gov (United States)

    Ladner, Travis R; He, Lucy; Davis, Brandon J; Froehler, Michael T; Mocco, J

    2016-04-01

    Herniation, with possible embolization, of coils into the parent vessel following aneurysm coiling remains a frequent challenge. For this reason, balloon or stent assisted embolization remains an important technique. Despite the use of balloon remodeling, there are occasions where, on deflation of the balloon, some coils, or even the entire coil mass, may migrate. We report the successful use of a simultaneous adjacent stent deployment bailout technique in order to salvage coil prolapse during balloon remodeling in three patients. Case No 1 was a wide neck left internal carotid artery bifurcation aneurysm, measuring 9 mm×7.9 mm×6 mm with a 5 mm neck. Case No 2 was a complex left superior hypophyseal artery aneurysm, measuring 5.3 mm×4 mm×5 mm with a 2.9 mm neck. Case No 3 was a ruptured right posterior communicating artery aneurysm, measuring 4 mm×4 mm×4.5 mm with a 4 mm neck. This technique successfully returned the prolapsed coil mass into the aneurysm sac in all cases without procedural complications. The closed cell design of the Enterprise VRD (Codman and Shurtleff Inc, Raynham, Massachusetts, USA) makes it ideal for this bailout technique, by allowing the use of an 0.021 inch delivery catheter (necessary for simultaneous access) and by avoiding the possibility of an open cell strut getting caught on the deflated balloon. We hope this technique will prove useful to readers who may find themselves in a similar predicament. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. Optimal application of the Contura multilumen balloon breast brachytherapy catheter vacuum port to deliver accelerated partial breast irradiation.

    Science.gov (United States)

    Tokita, Kenneth M; Cuttino, Laurie W; Vicini, Frank A; Arthur, Douglas W; Todor, Dorin A; Julian, Thomas B; Lyden, Maureen R

    2011-01-01

    The impact of using the Contura multilumen balloon (MLB) (SenoRx, Inc., Irvine, CA) breast brachytherapy catheter's vacuum port in patients treated with accelerated partial breast irradiation (APBI) was analyzed. Data from 32 patients at two sites were reviewed. Variables analyzed included the seroma fluid (SF):air volume around the MLB before and after vacuum port use and on its ability to improve (1) the eligibility of patients for APBI and (2) dose coverage of the planning target volume for evaluation (PTV_EVAL) in eligible patients. The median SF/air volume before vacuum removal was 6.8 cc vs. 0.8 cc after vacuum removal (median reduction in SF/air volume was 90.5%). Before vacuum port use, the median SF/air volume expressed as percentage of the PTV_EVAL was 7.8% (range, 1.9-26.6) in all patients. After application of the vacuum, this was reduced to 1.2%. Before vacuum port use, 10 (31.3%) patients were not considered acceptable candidates for APBI because the SF/air volume:PTV_EVAL ratio (SF:PTV) was greater than 10% (range, 10.1-26.6%; median, 15.2%). After vacuum port use, the median SF:PTV ratio was 1.6% for a median reduction of 91.5%. In addition, the percentage of the prescribed dose covering greater than or equal to 90% of the PTV_EVAL proportionally increased a median of 8% (range, 3-10%) in eligible patients. Use of the Contura MLB vacuum port significantly improved the conformity of the target tissue to the balloon surface, leading to reproducible dose delivery and increased target volume coverage. In addition, application of the vacuum allowed the safe treatment of unacceptable patients with APBI. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  15. Boston's balloon dilatation for treatment of cardiac achalasia

    International Nuclear Information System (INIS)

    Yin Jianguo; Song Jinwen; Yang Yan; Liu Xiaohong; Fu Zhiming; Zhang Yaqin

    2001-01-01

    Objective: To review and summarize effectiveness and method of the Boston's balloon dilation in cardiac achalasia. Methods: The intensified guide wire was inserted into stomach through mouth cavity under TV control. The Boston's balloon was inserted to the cardiac stricture through the guide wire and dilatated with 15% contrast medium with to a maximum diameter for five minutes and then the balloon was dilatated again for 3-5 minutes, all together for 3-4 times. The severe stricture must be pre-dilatated with 20-25 mm diameter balloon. Results: The balloon insertion was technically successful in all 26 patients. The once success of balloon dilation was achieved in 24 patients and twice in other 2. Follow-up time was from 2 weeks to 31 months (mean 10.6 months). Recurrent stenosis had not occurred in all patients. Remission rate of dysphagia was 100%. Esophageal reflux occurred in 3 patients. Conclusions: The Boston's balloon dilatation is simple and effective for treatment of cardiac achalasia. The method sometimes may replace surgical procedure

  16. Benefits of ambulatory axillary intra-aortic balloon pump for circulatory support as bridge to heart transplant.

    Science.gov (United States)

    Umakanthan, Ramanan; Hoff, Steven J; Solenkova, Natalia; Wigger, Mark A; Keebler, Mary E; Lenneman, Andrew; Leacche, Marzia; Disalvo, Thomas G; Ooi, Henry; Naftilan, Allen J; Byrne, John G; Ahmad, Rashid M

    2012-05-01

    Axillary intra-aortic balloon pump therapy has been described as a bridge to transplant. Advantages over femoral intra-aortic balloon pump therapy include reduced incidence of infection and enhanced patient mobility. We identified the patients who would benefit most from this therapy while awaiting heart transplantation. We conducted a single-center, retrospective observational study to evaluate outcomes from axillary intra-aortic balloon pump therapy. These included hemodynamic parameters, duration of support, and success in bridging to transplant. We selected patients on the basis of history of sternotomy, elevated panel-reactive antibody, and small body habitus. Patients were made to ambulate aggressively beginning on postoperative day 1. Between September 2007 and September 2010, 18 patients underwent axillary intra-aortic balloon pump therapy. All patients had the devices placed through the left axillary artery with a Hemashield side graft (Boston Scientific, Natick, Mass). Before axillary placement, patients underwent femoral placement to demonstrate hemodynamic benefit. Duration of support ranged from 5 to 63 days (median = 19 days). There was marked improvement in ambulatory potential and hemodynamic parameters, with minimal blood transfusion requirements. There were no device-related infections. Some 72% of the patients (13/18) were successfully bridged to transplantation. Axillary intra-aortic balloon pump therapy provides excellent support for selected patients as a bridge to transplant. The majority of the patients were successfully bridged to transplant and discharged. Although this therapy has been described in previous studies, this is the largest series to incorporate a regimen of aggressive ambulation with daily measurements of distances walked. Copyright © 2012. Published by Mosby, Inc.

  17. In vitro analysis of balloon cuffing phenomenon: inherent biophysical properties of catheter material or mechanics of catheter balloon deflation?

    Science.gov (United States)

    Chung, Eric; So, Karina

    2012-06-01

    To investigates the different methods of balloon deflation, types of urinary catheters and exposure to urine media in catheter balloon cuffing. Bardex®, Bard-Lubri-Sil®, Argyle®, Releen® and Biocath® were tested in sterile and E.Coli inoculated urine at 0, 14 and 28 days. Catheter deflation was performed with active deflation; passive deflation; passive auto-deflation; and excision of the balloon inflow channel. Balloon cuffing was assessed objectively by running the deflated balloon over a plate of agar and subjectively by 3 independent observers. Bardex®, Argyle® and Biocath® showed greater degree of catheter balloon cuffing (p deflation was the worst method (p 0.05). Linear regression model analysis confirmed time as the most significant factor. The duration of catheters exposure, different deflation methods and types of catheters tested contributed significantly to catheter balloon cuffing (p < 0.01).

  18. The Rocket Balloon (Rocketball): Applications to Science, Technology, and Education

    Science.gov (United States)

    Esper, Jaime

    2009-01-01

    Originally envisioned to study upper atmospheric phenomena, the Rocket Balloon system (or Rocketball for short) has utility in a range of applications, including sprite detection and in-situ measurements, near-space measurements and calibration correlation with orbital assets, hurricane observation and characterization, technology testing and validation, ground observation, and education. A salient feature includes the need to reach space and near-space within a critical time-frame and in adverse local meteorological conditions. It can also provide for the execution of technology validation and operational demonstrations at a fraction of the cost of a space flight. In particular, planetary entry probe proof-of-concepts can be examined. A typical Rocketball operational scenario consists of a sounding rocket launch and subsequent deployment of a balloon above a desired location. An obvious advantage of this combination is the additional mission 'hang-time' rendered by the balloon once the sounding rocket flight is completed. The system leverages current and emergent technologies at the NASA Goddard Space Flight Center and other organizations.

  19. Indoor Modelling from Slam-Based Laser Scanner: Door Detection to Envelope Reconstruction

    Science.gov (United States)

    Díaz-Vilariño, L.; Verbree, E.; Zlatanova, S.; Diakité, A.

    2017-09-01

    Updated and detailed indoor models are being increasingly demanded for various applications such as emergency management or navigational assistance. The consolidation of new portable and mobile acquisition systems has led to a higher availability of 3D point cloud data from indoors. In this work, we explore the combined use of point clouds and trajectories from SLAM-based laser scanner to automate the reconstruction of building indoors. The methodology starts by door detection, since doors represent transitions from one indoor space to other, which constitutes an initial approach about the global configuration of the point cloud into building rooms. For this purpose, the trajectory is used to create a vertical point cloud profile in which doors are detected as local minimum of vertical distances. As point cloud and trajectory are related by time stamp, this feature is used to subdivide the point cloud into subspaces according to the location of the doors. The correspondence between subspaces and building rooms is not unambiguous. One subspace always corresponds to one room, but one room is not necessarily depicted by just one subspace, for example, in case of a room containing several doors and in which the acquisition is performed in a discontinue way. The labelling problem is formulated as combinatorial approach solved as a minimum energy optimization. Once the point cloud is subdivided into building rooms, envelop (conformed by walls, ceilings and floors) is reconstructed for each space. The connectivity between spaces is included by adding the previously detected doors to the reconstructed model. The methodology is tested in a real case study.

  20. Development of inverter for elevator door control

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J.K.; Choi, U.D.; Jung, M.K.; Choi, S.K. [HHI R and D Center (Korea, Republic of); Yun, J.H.; Han, S.B. [HELCO R and D Center (Korea, Republic of)

    1995-07-01

    Most of the elevator door controllers have been controlled by DC Motors as an actuator. Recently, The control system using AC induction motor and general purpose inverter has been applied to control of elevator door. But there are some difficulties in making use of this system, such as adjustment of door speed pattern, door open-close time, and security of passenger safety. In order to solve these problems, a special inverter has been developed with an encoder feedback. From the result of field-test, we proved that a special inverter with encoder feedback device has come to considerable effect. Until now about 1,200 sets of these inverters are operated in Korea and about 100 sets are operated in South-east Asia. (author). 3 refs., 10 figs., 3 tabs.

  1. Median survival time of patients after transcatheter chemo-embolization for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Haider, Z.; Haq, T.; Munir, K.; Usman, M.U.; Azeemuddin, M.

    2006-01-01

    Objective: To determine the effect on survival after trans arterial chemo embolization (TACE) in patients with unresectable hepatocellular carcinoma (HCC). Design: Longitudinal cohort study. Place and Duration of Study: Radiology Department, The Aga Khan University Hospital, Stadium Road, Karachi, from December 1997 to September 2005. Patients and Methods: Patients undergoing TACE procedure for HCC were prospectively followed. Forty three patients were enrolled from December 1997 to March 2003 in the study and subjected to chemo embolization therapy. Eight out of 43 patients were excluded from the study, who lost to follow-up. All the patients were followed till their death. Median and mean survival were calculated. Results: The median survival of these 35 patients was 410 days (13.6 months), with 95% confidence interval (236 days lower bound and 536 days upper bound). Mean survival time was 603 days (20.1 months) with 95% confidence interval (394 days lower bound and 812 days upper bound). There was significant difference in mean survival time (in days) by Child's Pugh class (X2 = 12.384; df=2, p-value=0.002). Conclusion: The study showed that TACE is an effective palliative treatment. TACE increases the median survival time. (author)

  2. INDOOR MODELLING FROM SLAM-BASED LASER SCANNER: DOOR DETECTION TO ENVELOPE RECONSTRUCTION

    Directory of Open Access Journals (Sweden)

    L. Díaz-Vilariño

    2017-09-01

    Full Text Available Updated and detailed indoor models are being increasingly demanded for various applications such as emergency management or navigational assistance. The consolidation of new portable and mobile acquisition systems has led to a higher availability of 3D point cloud data from indoors. In this work, we explore the combined use of point clouds and trajectories from SLAM-based laser scanner to automate the reconstruction of building indoors. The methodology starts by door detection, since doors represent transitions from one indoor space to other, which constitutes an initial approach about the global configuration of the point cloud into building rooms. For this purpose, the trajectory is used to create a vertical point cloud profile in which doors are detected as local minimum of vertical distances. As point cloud and trajectory are related by time stamp, this feature is used to subdivide the point cloud into subspaces according to the location of the doors. The correspondence between subspaces and building rooms is not unambiguous. One subspace always corresponds to one room, but one room is not necessarily depicted by just one subspace, for example, in case of a room containing several doors and in which the acquisition is performed in a discontinue way. The labelling problem is formulated as combinatorial approach solved as a minimum energy optimization. Once the point cloud is subdivided into building rooms, envelop (conformed by walls, ceilings and floors is reconstructed for each space. The connectivity between spaces is included by adding the previously detected doors to the reconstructed model. The methodology is tested in a real case study.

  3. [When doors slam, fingers jam!].

    Science.gov (United States)

    Claudet, I; Toubal, K; Carnet, C; Rekhroukh, H; Zelmat, B; Debuisson, C; Cahuzac, J-P

    2007-08-01

    Epidemiological analysis in a universitary paediatric emergency unit of children admitted after accidental injuries resulting from fingers crushed in a door. Prospective, descriptive cohort study from September 6th, 2004 to July 1st, 2005 included all children admitted for finger injuries crushed in a non-automatic door. included accidents due to automatic doors, toy's or refrigerator doors, families who refused to participate to the study or families who had left the waiting area before medical examination. Collected data were patient and family characteristics, accident characteristics and its management. Three hundred and forty children affected by 427 digital lesions were included. The mean age was 5.5+/-3.8 years (range 4 months - 15.5 years). Male/female ratio was equal to 1.2: 1. Fifty-eight percent of patients belonged to families composed of 3 or more siblings. Ninety-three per cent of families came to hospital within the first 2 hours after the accident (mean delay 99+/-162 min, median range 54 minutes). Location of the accident was: domestic (62%, at home (64%)), at school (17%). Locations within the home were: the bedroom (33%), bathroom and toilets (21%). An adult was present in 75% of cases and responsible for the trauma in 25% of accidents, another child in 44%. The finger or fingers were trapped on the hinge side in 57% of patients. No specific safeguard devices were used by 94% of families. Among victims, 20% had several crushed digits; left and right hand were injured with an equal frequency. The commonest involved digits were: the middle finger (29%), the ring finger (23%). The nail plate was damaged in 60% of digital lesions, associated with a wound (50%), a distal phalanx fracture (P3) (12%). Six children had a partial or complete amputation of P3, 2 children a lesion of the extensor tendon, 1 child had a rupture of the external lateral ligament. Three percent of children required an admission to the paediatric orthopaedic surgery unit. Post

  4. An Overview of Current and Future Stratospheric Balloon Mission Capabilities

    Science.gov (United States)

    Smith, Michael

    The modern stratospheric balloon has been used for a variety of missions since the late 1940's. Capabilities of these vehicles to carry larger payloads, fly to higher altitudes, and fly for longer periods of time have increased dramatically over this time. In addition to these basic performance metrics, reliability statistics for balloons have reached unprecedented levels in recent years. Balloon technology developed in the United States in the last decade has the potential to open a new era in economical space science using balloons. As always, the advantage of the balloon platform is the fact that missions can be carried out at a fraction of the cost and schedule of orbital missions. A secondary advantage is the fact that instruments can be re-flown numerous times while upgrading sensor and data processing technologies from year to year. New mission capabilities now have the potential for enabling ground breaking observations using balloons as the primary platform as opposed to a stepping stone to eventual orbital observatories. The limit of very high altitude balloon missions will be explored with respect to the current state of the art of balloon materials and fabrication. The same technological enablers will also be applied to possibilities for long duration missions at mid latitudes with payloads of several tons. The balloon types and their corresponding mission profiles will be presented in a performance matrix that will be useful for potential scientific users in planning future research programs.

  5. Transhepatic Balloon Dilatation of Early Biliary Strictures in Pediatric Liver Transplantation: Successful Initial and Mid-Term Outcome

    International Nuclear Information System (INIS)

    Belenky, Alexander; Mor, Eytan; Bartal, Gabriel; Atar, Eli; Shapiro, Riki; Bar-Nathan, Nathan; Bachar, Gil N.

    2004-01-01

    Purpose: To evaluate the initial and mid-term outcomes of transhepatic balloon dilatation for the treatment of early biliary strictures in lateral left-segment liver transplants in young children.Methods: Between April 1997 and May 2001, seven children aged 9 months to 6 years with nine benign strictures in left-segment liver grafts were treated percutaneously. Sessions of two or three dilations were performed three or four times at average intervals of 10-20 days. In each session, the biliary stenoses were gradually dilated using balloons of 3-7 mm. Follow-up ranged from 12 to 54 months (mean 27 months, median 12 months). Clinical success was defined as resolution of the stenosis, normalization of liver enzymes and lack of clinical symptoms. Results: Technical success was achieved in all nine strictures. Hemobilia occurred in one patient and was successfully treated. On follow-up, all patients had complete clinical recovery with normalization of liver function and imaging of patent bile ducts. Conclusion: Balloon dilatation is an effective and relatively safe method for the treatment of early biliary strictures in left-segment liver transplantation in young children. We recommend this approach as the initial treatment for early strictures. Metal stents or surgery should be reserved for patients with late appearance of strictures or failure of balloon dilatation

  6. From acoustic descriptors to evoked quality of car door sounds.

    Science.gov (United States)

    Bezat, Marie-Céline; Kronland-Martinet, Richard; Roussarie, Vincent; Ystad, Sølvi

    2014-07-01

    This article describes the first part of a study aiming at adapting the mechanical car door construction to the drivers' expectancies in terms of perceived quality of cars deduced from car door sounds. A perceptual cartography of car door sounds is obtained from various listening tests aiming at revealing both ecological and analytical properties linked to evoked car quality. In the first test naive listeners performed absolute evaluations of five ecological properties (i.e., solidity, quality, weight, closure energy, and success of closure). Then experts in the area of automobile doors categorized the sounds according to organic constituents (lock, joints, door panel), in particular whether or not the lock mechanism could be perceived. Further, a sensory panel of naive listeners identified sensory descriptors such as classical descriptors or onomatopoeia that characterize the sounds, hereby providing an analytic description of the sounds. Finally, acoustic descriptors were calculated after decomposition of the signal into a lock and a closure component by the Empirical Mode Decomposition (EMD) method. A statistical relationship between the acoustic descriptors and the perceptual evaluations of the car door sounds could then be obtained through linear regression analysis.

  7. Door Hardware and Installations; Carpentry: 901894.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    The curriculum guide outlines a course designed to provide instruction in the selection, preparation, and installation of hardware for door assemblies. The course is divided into five blocks of instruction (introduction to doors and hardware, door hardware, exterior doors and jambs, interior doors and jambs, and a quinmester post-test) totaling…

  8. How to perform combined cutting balloon and high pressure balloon valvuloplasty for dogs with subaortic stenosis.

    Science.gov (United States)

    Kleman, Mandi E; Estrada, Amara H; Maisenbacher, Herbert W; Prošek, Robert; Pogue, Brandon; Shih, Andre; Paolillo, Joseph A

    2012-01-01

    Subvalvular aortic stenosis (SAS) is one of the most common congenital cardiac malformations in dogs. Unfortunately, the long term success rate and survival data following either open heart surgery or catheter based intervention has been disappointing in dogs with severe subaortic stenosis. Medical therapy is currently the only standard recommended treatment option. A cutting balloon dilation catheter has been used successfully for resistant coronary artery and peripheral pulmonary arterial stenoses in humans. This catheter is unique in that it has the ability to cut, or score, the stenotic region prior to balloon dilatation of the stenosis. The use of cutting balloon valvuloplasty combined with high pressure valvuloplasty for dogs with severe subaortic stenosis has recently been reported to be a safe and feasible alternative therapeutic option. The following report describes this technique, outlines the materials required, and provides some 'tips' for successful percutaneous subaortic balloon valvuloplasty. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Retrofit curtain for overhead doors

    Energy Technology Data Exchange (ETDEWEB)

    Leckie, R E

    1987-12-29

    A heat insulating curtain has been developed for reducing heat losses through overhead doors of the type commonly found in industrial warehouses. The curtain consists of a reinforced polyester fabric attached to the outside top of the overhead door and moves with the door as it opens and closes. A T-shaped edge track seals the edges of the curtain to the door frame; the edge of the curtain is also T-shaped and runs up and down the track as the curtain is raised and lowered. The curtain fabric is ultraviolet resistant, durable, flexible, and transparent, and transforms the door into a solar collector which provides solar heated air to the building interior. Two curtains have been satisfactorily installed and tested at a warehouse in Calgary, Alberta. A market evaluation study was conducted to determine the possible buyers for such a door curtain. A target market consisting of those wishing to fix old, leaky doors was selected and a marketing strategy developed. The described strategy includes product development, pricing, distribution, promotion, and advertising. 2 figs., 1 tab.

  10. Energy from solar balloons

    Energy Technology Data Exchange (ETDEWEB)

    Grena, Roberto [C. R. Casaccia, via Anguillarese 301, 00123 Roma (Italy)

    2010-04-15

    Solar balloons are hot air balloons in which the air is heated directly by the sun, by means of a black absorber. The lift force of a tethered solar balloon can be used to produce energy by activating a generator during the ascending motion of the balloon. The hot air is then discharged when the balloon reaches a predefined maximum height. A preliminary study is presented, along with an efficiency estimation and some considerations on possible realistic configurations. (author)

  11. An Intervention to Reduce the Time Interval Between Hospital Entry and Emergency Coronary Angiography in Patients with ST-Elevation Myocardial Infarction.

    Science.gov (United States)

    Karkabi, Basheer; Jaffe, Ronen; Halon, David A; Merdler, Amnon; Khader, Nader; Rubinshtein, Ronen; Goldstein, Jacob; Zafrir, Barak; Zissman, Keren; Ben-Dov, Nissan; Gabrielly, Michael; Fuks, Alex; Shiran, Avinoam; Adawi, Salim; Hellman, Yaron; Shahla, Johny; Halabi, Salim; Flugelman, Moshe Y; Cohen, Shai; Bergman, Irina; Kassem, Sameer; Shapira, Chen

    2017-09-01

    Outcomes of patients with acute ST-elevation myocardial infarction (STEMI) are strongly correlated to the time interval from hospital entry to primary percutaneous coronary intervention (PPCI). Current guidelines recommend a door to balloon time of < 90 minutes. To reduce the time from hospital admission to PPCI and to increase the proportion of patients treated within 90 minutes. In March 2013 the authors launched a seven-component intervention program:  Direct patient evacuation by out-of-hospital emergency medical services to the coronary intensive care unit or catheterization laboratory Education program for the emergency department staff Dissemination of information regarding the urgency of the PPCI decision Activation of the catheterization team by a single phone call Reimbursement for transportation costs to on-call staff who use their own cars Improvement in the quality of medical records Investigation of failed cases and feedback. During the 14 months prior to the intervention, initiation of catheterization occurred within 90 minutes of hospital arrival in 88/133 patients(65%); during the 18 months following the start of the intervention, the rate was 181/200 (90%) (P < 0.01). The respective mean/median times to treatment were 126/67 minutes and 52/47 minutes (P < 0.01). Intervention also resulted in shortening of the time interval from hospital entry to PPCI on nights and weekends. Following implementation of a comprehensive intervention, the time from hospital admission to PPCI of STEMI patients shortened significantly, as did the proportion of patients treated within 90 minutes of hospital arrival.

  12. Median and Morphological Specialized Processors for a Real-Time Image Data Processing

    Directory of Open Access Journals (Sweden)

    Kazimierz Wiatr

    2002-01-01

    Full Text Available This paper presents the considerations on selecting a multiprocessor MISD architecture for fast implementation of the vision image processing. Using the author′s earlier experience with real-time systems, implementing of specialized hardware processors based on the programmable FPGA systems has been proposed in the pipeline architecture. In particular, the following processors are presented: median filter and morphological processor. The structure of a universal reconfigurable processor developed has been proposed as well. Experimental results are presented as delays on LCA level implementation for median filter, morphological processor, convolution processor, look-up-table processor, logic processor and histogram processor. These times compare with delays in general purpose processor and DSP processor.

  13. Flight Qualification of the NASA's Super Pressure Balloon

    Science.gov (United States)

    Cathey, Henry; Said, Magdi; Fairbrother, Debora

    Designs of new balloons to support space science require a number of actual flights under various flight conditions to qualify them to as standard balloon flight offerings to the science community. Development of the new Super Pressure Balloon for the National Aeronautics and Space Administration’s Balloon Program Office has entailed employing new design, analysis, and production techniques to advance the state of the art. Some of these advances have been evolutionary steps and some have been revolutionary steps requiring a maturing understanding of the materials, designs, and manufacturing approaches. The NASA Super Pressure Balloon development end goal is to produce a flight vehicle that is qualified to carry a ton of science instrumentation, at an altitude greater than 33 km while maintaining a near constant pressure altitude for extended periods of up to 100 days, and at any latitude on the globe. The NASA’s Balloon Program Office has pursued this development in a carefully executed incremental approach by gradually increasing payload carrying capability and increasing balloon volume to reach these end goal. A very successful test flight of a ~200,700 m3 balloon was launch in late 2008 from Antarctica. This balloon flew for over 54 days at a constant altitude and circled the Antarctic continent almost three times. A larger balloon was flown from Antarctica in early 2011. This ~422,400 m3 flew at a constant altitude for 22 days making one circuit around Antarctica. Although the performance was nominal, the flight was terminated via command to recover high valued assets from the payload. The balloon designed to reach the program goals is a ~532,200 m3 pumpkin shaped Super Pressure Balloon. A test flight of this balloon was launched from the Swedish Space Corporation’s Esrange Balloon Launch Facilities near Kiruna, Sweden on 14 August, 2012. This flight was another success for this development program. Valuable information was gained from this short test

  14. Viscoelastic behaviour of pumpkin balloons

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    2008-11-01

    The lobes of the NASA ULDB pumpkin-shaped super-pressure balloons are made of a thin polymeric film that shows considerable time-dependent behaviour. A nonlinear viscoelastic model based on experimental measurements has been recently established for this film. This paper presents a simulation of the viscoelastic behaviour of ULDB balloons with the finite element software ABAQUS. First, the standard viscoelastic modelling capabilities available in ABAQUS are examined, but are found of limited accuracy even for the case of simple uniaxial creep tests on ULDB films. Then, a nonlinear viscoelastic constitutive model is implemented by means of a user-defined subroutine. This approach is verified by means of biaxial creep experiments on pressurized cylinders and is found to be accurate provided that the film anisotropy is also included in the model. A preliminary set of predictions for a single lobe of a ULDB is presented at the end of the paper. It indicates that time-dependent effects in a balloon structure can lead to significant stress redistribution and large increases in the transverse strains in the lobes.

  15. Upper gastrointestinal strictures: The results of balloon dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kil Woo; Lim, Hyo Keun; Choo, In Wook; Bae, Sang Hoon; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of); Yoo, Hyung Sik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1990-12-15

    Balloon catheter dilatation of upper gastrointestinal strictures is an accepted mode of therapy. The authors report the balloon dilatation in 11 consecutive patients. The lesions treated included 10 benign strictures, and 1 esophageal cancer. Esophageal balloon were ranged from 2 mm in diameter, 4 cm in length, to 30 mm in diameter, 8 cm in length. Inflation was held for from 30 to 60 seconds and then repeated two or three times during each session. The balloons were inflated to pressure of from 2 to 12 atmospheres. There were from 1 to 13 dilatations. Two esophageal perforations were occurred in one esophagitis patient and other lye stricture patient. Two perforations were not required any surgical repair. All dilatation were performed without anesthesia. All strictures were responded immediately to dilatation. Prolonged course of treatment were needed with chronic severe esophagitis, lye stricture, gastrojejunostomy with chemotherapy, as a result, all patients, except esophageal cancer, could take regular diet after balloon catheter dilatation. Balloon catheter dilatation of upper gastrointestinal stenosis was effective and safe. It should be considered before other methods of treatment applicable.

  16. Effect of intravenous TRO40303 as an adjunct to primary percutaneous coronary intervention for acute ST-elevation myocardial infarction: MITOCARE study results.

    Science.gov (United States)

    Atar, Dan; Arheden, Håkan; Berdeaux, Alain; Bonnet, Jean-Louis; Carlsson, Marcus; Clemmensen, Peter; Cuvier, Valérie; Danchin, Nicolas; Dubois-Randé, Jean-Luc; Engblom, Henrik; Erlinge, David; Firat, Hüseyin; Halvorsen, Sigrun; Hansen, Henrik Steen; Hauke, Wilfried; Heiberg, Einar; Koul, Sasha; Larsen, Alf-Inge; Le Corvoisier, Philippe; Nordrehaug, Jan Erik; Paganelli, Franck; Pruss, Rebecca M; Rousseau, Hélène; Schaller, Sophie; Sonou, Giles; Tuseth, Vegard; Veys, Julien; Vicaut, Eric; Jensen, Svend Eggert

    2015-01-07

    The MITOCARE study evaluated the efficacy and safety of TRO40303 for the reduction of reperfusion injury in patients undergoing revascularization for ST-elevation myocardial infarction (STEMI). Patients presenting with STEMI within 6 h of the onset of pain randomly received TRO40303 (n = 83) or placebo (n = 80) via i.v. bolus injection prior to balloon inflation during primary percutaneous coronary intervention in a double-blind manner. The primary endpoint was infarct size expressed as area under the curve (AUC) for creatine kinase (CK) and for troponin I (TnI) over 3 days. Secondary endpoints included measures of infarct size using cardiac magnetic resonance (CMR) and safety outcomes. The median pain-to-balloon time was 180 min for both groups, and the median (mean) door-to-balloon time was 60 (38) min for all sites. Infarct size, as measured by CK and TnI AUCs at 3 days, was not significantly different between treatment groups. There were no significant differences in the CMR-assessed myocardial salvage index (1-infarct size/myocardium at risk) (mean 52 vs. 58% with placebo, P = 0.1000), mean CMR-assessed infarct size (21.9 g vs. 20.0 g, or 17 vs. 15% of LV-mass) or left ventricular ejection fraction (LVEF) (46 vs. 48%), or in the mean 30-day echocardiographic LVEF (51.5 vs. 52.2%) between TRO40303 and placebo. A greater number of adjudicated safety events occurred in the TRO40303 group for unexplained reasons. This study in STEMI patients treated with contemporary mechanical revascularization principles did not show any effect of TRO40303 in limiting reperfusion injury of the ischaemic myocardium. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  17. A balloon-borne experiment to investigate the Martian magnetic field

    Science.gov (United States)

    Schwingenschuh, K.; Feldhofer, H.; Koren, W.; Jernej, I.; Stachel, M.; Riedler, W.; Slamanig, H.; Auster, H.-U.; Rustenbach, J.; Fornacon, H. K.; Schenk, H. J.; Hillenmaier, O.; Haerendel, G.; Yeroshenko, Ye.; Styashkin, V.; Zaroutzky, A.; Best, A.; Scholz, G.; Russell, C. T.; Means, J.; Pierce, D.; Luhmann, J. G.

    1996-03-01

    The Space Research Institute of the Austrian Academy, of Sciences (Graz, Austria) in cooperation with MPE (Berlin, Germany), GFZ Potsdam (Obs. Niemegk, Germany) IZMIRAN/IOFAN (Moscow, Russian) and IGPP/UCLA (Los Angeles, USA) is designing the magnetic field experiment MAGIBAL (MAGnetic field experiment aboard a martian BALloon) to investigate the magnetic field on the surface of Mars. The dual sensor fluxgate magnetometer is part of the MARS-98/MARS-TOGETHER balloon payload. During a ten days period the balloon will float over a distance of about 2000 km at altitudes between 0 and 4 km. Due to the limited power and telemetry allocation the magnetometer can transmit only one vector per ten seconds and spectral information in the frequency range from 2 - 25 Hz. The dynamic range is +/- 2000 nT. The main scientific objectives of the experiment are: • Determination of the magnetism of the Martian rocks • Investigation of the leakage of the solar wind induced magnetosphere using the correlation between orbiter and balloon observations • Measurement of the magnetic field profile between the orbiter and the surface of Mars during the descent phase of the balloon. Terrestrial test flights with a hot air balloon were performed in order to test the original MAGIBAL equipment under balloon flight conditions.

  18. Analysis of costs to dispense prescriptions in independently owned, closed-door long-term care pharmacies.

    Science.gov (United States)

    Carroll, Norman V; Rupp, Michael T; Holdford, David A

    2014-03-01

    developed to examine the impact of shorter dispensing cycles on LTC pharmacies' CTD. A prescription volume increase of 19% was assumed based on converting only solid oral branded drugs to short-cycle dispensing. A diverse sample of 64 closed-door LTC pharmacies returned usable surveys. Sales from dispensing to LTC facilities accounted for more than 98% of total sales. Respondents indicated that they currently dispensed 23% of total doses in 14-day-or-less cycles and 76% in 28-31 day cycles. Most pharmacies used automated medication packaging technology, heat and cold package sealers, bar code systems, sterile compounding hoods, LTC printers or labelers, and electronic prescribing. The median CTD was $13.54 with an interquartile range (25th to 75th percentiles) of $10.51 to $17.66. More than half of dispensing-related costs were from personnel expense, of which pharmacists and managers accounted for more than 40%. The results of the fixed and variable cost modeling suggested that converting solid oral brand-name drugs from 30-day to 14-day dispensing cycles would lower the median per prescription CTD to between $11.63 and $12.54, depending on the assumptions made about the effects of semivariable costs. However, this decrease in per prescription dispensing cost is dwarfed by an increase in total dispensing cost incurred by pharmacies that results from doubling the monthly volume of short-cycle prescriptions that must be dispensed. The result is that the typical LTC pharmacy in our sample incurred a CTD of $13.54 if the medication is dispensed in a 30-day cycle or $23.26 if the medication is dispensed in two 14-day cycles (at a cost of $11.63 for each cycle dispensed). Our results indicated a median CTD of $13.54 for the typical independently owned, closed-door LTC pharmacy. Moving to a shorter cycle would reduce pharmacies' average per-prescription CTD but would increase the number of prescriptions dispensed per month. Our results indicated that transitioning solid oral

  19. Clefting in pumpkin balloons

    Science.gov (United States)

    Baginski, F.; Schur, W.

    NASA's effort to develop a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, focuses on a pumpkin shape super-pressure design. It has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired stable state instead. Hoop stress considerations in the pumpkin design leads to choosing the lowest possible bulge radius, while robust deployment is favored by a large bulge radius. Some qualitative understanding of design aspects on undesired equilibria in pumpkin balloons has been obtained via small-scale balloon testing. Poorly deploying balloons have clefts, but most gores away from the cleft deploy uniformly. In this paper, we present models for pumpkin balloons with clefts. Long term success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and means for quantitative assessment of measures that prevent their occurrence. This paper attempts to determine numerical thresholds of design parameters that distinguish between properly deploying designs and improperly deploying designs by analytically investigating designs in the vicinity of criticality. Design elements which may trigger the onset undesired equilibria and remedial measures that ensure deployment are discussed.

  20. Utility of newly developed short-type double-balloon endoscopy for endoscopic retrograde cholangiography in postoperative patients.

    Science.gov (United States)

    Shimatani, Masaaki; Tokuhara, Mitsuo; Kato, Kota; Miyamoto, Sachi; Masuda, Masataka; Sakao, Masayuki; Fukata, Norimasa; Miyoshi, Hideaki; Ikeura, Tsukasa; Takaoka, Makoto; Okazaki, Kazuichi

    2017-07-01

    The utility of conventional short-type double-balloon endoscopy (DBE) for pancreatobiliary disease in patients with postoperative anatomy had been widely acknowledged and accepted. However, some technical difficulties yet remained. In an attempt to solve these problems, the new short-type DBE (N-short DBE) was uniquely designed for therapeutic endoscopic retrograde cholangiography (ERC) in postoperative patients. The aim of this study was to evaluate the usefulness of N-short DBE for ERC in postoperative patients. From August 2015 to April 2016, ERC using N-short DBE (DB-ERC) was performed in 100 postoperative patients (112 procedures). We retrospectively studied the success rate of reaching the blind end, the median time to reach the blind end, the diagnostic success rate, the therapeutic success rate, the median time to complete ERC-related interventions, the overall success rate, the median time to complete DB-ERC, and adverse events. The success rate of reaching the blind end was 99.1%. The median time to reach the blind end was 10 min (interquartile range [IQR], 6-19 min). The diagnostic success rate was 98.2%. The therapeutic success rate was 100%. The median time to complete ERC-related interventions was 36 min (IQR, 22-62 min). The overall DB-ERC success rate was 97.3%. The median time to complete DB-ERC was 54 min (IQR, 37-73 min). The occurrence of adverse events was 2.7%. The N-short DBE for ERC in postoperative patients is useful and safe. DB-ERC is promising therapeutic modality in such patients and should be selected as the first-line policy. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  1. Real-Time Study of Prostate Intrafraction Motion During External Beam Radiotherapy With Daily Endorectal Balloon

    Energy Technology Data Exchange (ETDEWEB)

    Both, Stefan, E-mail: Stefan.Both@uphs.upenn.edu [Department of Radiation Oncology, Hospital of University of Pennsylvania, Philadelphia, PA (United States); Wang, Ken Kang-Hsin; Plastaras, John P.; Deville, Curtiland; Bar Ad, Voika; Tochner, Zelig; Vapiwala, Neha [Department of Radiation Oncology, Hospital of University of Pennsylvania, Philadelphia, PA (United States)

    2011-12-01

    Purpose: To prospectively investigate intrafraction prostate motion during radiofrequency-guided prostate radiotherapy with implanted electromagnetic transponders when daily endorectal balloon (ERB) is used. Methods and Materials: Intrafraction prostate motion from 24 patients in 787 treatment sessions was evaluated based on three-dimensional (3D), lateral, cranial-caudal (CC), and anterior-posterior (AP) displacements. The mean percentage of time with 3D, lateral, CC, and AP prostate displacements >2, 3, 4, 5, 6, 7, 8, 9, and 10 mm in 1 minute intervals was calculated for up to 6 minutes of treatment time. Correlation between the mean percentage time with 3D prostate displacement >3 mm vs. treatment week was investigated. Results: The percentage of time with 3D prostate movement >2, 3, and 4 mm increased with elapsed treatment time (p < 0.05). Prostate movement >5 mm was independent of elapsed treatment time (p = 0.11). The overall mean time with prostate excursions >3 mm was 5%. Directional analysis showed negligible lateral prostate motion; AP and CC motion were comparable. The fraction of time with 3D prostate movement >3 mm did not depend on treatment week of (p > 0.05) over a 4-minute mean treatment time. Conclusions: Daily endorectal balloon consistently stabilizes the prostate, preventing clinically significant displacement (>5 mm). A 3-mm internal margin may sufficiently account for 95% of intrafraction prostate movement for up to 6 minutes of treatment time. Directional analysis suggests that the lateral internal margin could be further reduced to 2 mm.

  2. [A clinical observation of percutaneous balloon dilation and maintenance percutaneous transhepatic cholangial catheter drainage for treatment of 21 patients with benign biliary strictures and difficult endoscopy].

    Science.gov (United States)

    Pan, Jie; Shi, Hai-feng; Li, Xiao-guang; Zhang, Xiao-bo; Liu, Wei; Jin, Zheng-yu; Hong, Tao; Yang, Ai-ming; Yang, Ning

    2012-06-01

    To investigate the value of percutaneous balloon dilation and percutaneous transhepatic cholangial drainage (PTCD) catheter maintenance in the treatment of benign biliary strictures. The clinical data of 21 patients with benign biliary strictures at Peking Union Medical College Hospital from June 2005 to June 2011 were retrospectively studied, in which 12 patients in severe stricture (stenosis > 70%) were treated with percutaneous balloon dilation and PTCD catheter placed across the stricture, while another 9 patients in median stricture (stenosis stenosis was seen in 2 patients. A severe complication with biliary artery branch rupture and massive hemobilia was seen in 1 patient during balloon dilation. Of the 9 patients only treated with 1 - 12 months (median: 6 months) of PTCD catheter placement, 7 patients had the catheter successfully removed. In the follow-up of 5 - 18 months (median: 8 months), patency of bile duct was preserved in 5 of 7 patients, and recurrent stenosis was seen in 2 patients. No severe complication occurred. When endoscopy therapy is failed or the patient can't undergo endoscopy therapy, the percutaneous balloon dilation and PTCD catheter maintenance method is an effective alternative therapeutic approach in the treatment of benign biliary strictures. The moderate benign biliary stricture may be effectively treated only by the PTCD catheter maintenance method.

  3. Meshed-Pumpkin Super-Pressure Balloon Design

    Science.gov (United States)

    Jones, Jack; Yavrouian, Andre

    2003-01-01

    An improved, lightweight design has been proposed for super-pressure balloons used to carry scientific instruments at high altitudes in the atmosphere of Earth for times as long as 100 days. [A super-pressure balloon is one in which the pressure of the buoyant gas (typically, helium) is kept somewhat above ambient pressure in order to maintain approximately constant density and thereby regulate the altitude.] The proposed design, called "meshed pumpkin," incorporates the basic concept of the pumpkin design, which is so named because of its appearance. The pumpkin design entails less weight than does a spherical design, and the meshed-pumpkin design would reduce weight further. The basic idea of the meshed-pumpkin design is to reinforce the membrane of a pumpkin balloon by attaching a strong, lightweight fabric mesh to its outer surface. The reinforcement would make it possible to reduce the membrane mass to one-third or less of that of the basic pumpkin design while retaining sufficient strength to enable the balloon to remain at approximately constant altitude for months.

  4. Effect of education on a chest pain mnemonic on door-to-ECG time.

    Science.gov (United States)

    Ballard, Nancy; Bairan, Annette; Newberry, Lorene; Van Brackle, Lewis; Barnett, Gwen

    2011-05-01

    Acute myocardial infarction (AMI) continues to contribute to both death and disability in both men and women. The first step in early intervention is an ECG. Atypically presenting patients, especially those who present by self-transport, are more likely to experience delays. The purpose of this study was to evaluate the effect of a new chest pain mnemonic (CPM) as a teaching tool for rapid recognition of AMI patients arriving by self-transport in ED triage in an effort to improve door-to-ECG (DTE) time. This study is a longitudinal, quasi-experimental quantitative study. Instruction and evaluation of nurses' knowledge related to identification of AMI before and after instruction on the CPM education (intervention) were coordinated by the emergency clinical nurse specialist. The study sample for the educational intervention included 26 nurses (15% of total population) from 4 emergency departments. Ad hoc queries of the National Registry for Myocardial Infarction database for patients arriving by self-transport to the emergency department were done to examine DTE before and after intervention. The pretests and post-tests of the nurses were analyzed with a paired t test, and the pre- and post-intervention DTE times were analyzed by log-linear modeling. Evaluation of nurses' knowledge before and after CPM education indicated an improvement in DTE time, although it was not statistically significant. There was a significant improvement in DTE time for 2 hospitals that was somewhat negated in the aggregate data. There was a noted trend that showed an advantage in DTE time associated with male patients. Inclusion of tools such as the CPM in education programs for emergency nurses improved rapid recognition of AMI patients presenting via self-transport to the emergency department. Attention to gender differences in patient presentation should be included in future CPM education, and tools to assist nurses in the early recognition of AMI need to be developed. Investigation

  5. Balloon sinuplasty

    OpenAIRE

    Ahmad, Zahoor

    2010-01-01

    Balloon sinuplasty is a technique in endoscopic sinus surgery that involves minimally invasive procedures to dilate the obstructed or stenosed anatomical sinus pathways. Procedure is derived from the well-recognized techinique of angioplasty. This article highlights the procedural methods with review of literature and my personal experience in balloon sinupalsty.

  6. Cleft formation in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank E.; Brakke, Kenneth A.; Schur, Willi W.

    NASA’s development of a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, centers on a pumpkin shape super-pressure design. Under certain circumstances, it has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired state instead. Success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and developing of means for the quantitative assessment of design measures that prevent the occurrence of undesired equilibrium. In this paper, we will use the concept of stability to classify cyclically symmetric equilibrium states at full inflation and pressurization. Our mathematical model for a strained equilibrium balloon, when applied to a shape that mimics the Phase IV-A balloon of Flight 517, predicts instability at float. Launched in Spring 2003, this pumpkin balloon failed to deploy properly. Observations on pumpkin shape type super-pressure balloons that date back to the 1980s suggest that within a narrowly defined design class of pumpkin shape super-pressure balloons where individual designs are fully described by the number of gores ng and by a single measure of the bulging gore shape, the designs tend to become more vulnerable with the growing number of gores and with the diminishing size of the bulge radius rB Weight efficiency considerations favor a small bulge radius, while robust deployment into the desired cyclically symmetrical configuration becomes more likely with an increased bulge radius. In an effort to quantify this dependency, we will explore the stability of a family of balloon shapes parametrized by (ng, rB) which includes a design that is very similar, but not identical, to the balloon of Flight 517. In addition, we carry out a number of simulations that demonstrate other aspects related to multiple equilibria of pumpkin balloons.

  7. Investigation of hot air balloon fatalities.

    Science.gov (United States)

    McConnell, T S; Smialek, J E; Capron, R G

    1985-04-01

    The rising popularity of the sport of hot air ballooning has been accompanied by several recent incidents, both in this country and other parts of the world, where mechanical defects and the improper operation of balloons have resulted in several fatalities. A study was conducted to identify the location and frequency of hot air ballooning accidents. Furthermore, the study attempted to identify those accidents that were the result of improper handling on the part of the balloon operators and those that were related to specific defects in the construction of the balloon. This paper presents a background of the sport of hot air ballooning, together with an analysis of the construction of a typical hot air balloon, pointing out the specific areas where defects may occur that could result in a potential fatal balloon crash. Specific attention is given to the two recent balloon crashes that occurred in Albuquerque, N.M., hot air balloon capital of the world, and that resulted in multiple fatalities.

  8. Immediate balloon deflation for prevention of persistent phrenic nerve palsy during pulmonary vein isolation by balloon cryoablation.

    Science.gov (United States)

    Ghosh, Justin; Sepahpour, Ali; Chan, Kim H; Singarayar, Suresh; McGuire, Mark A

    2013-05-01

    Persistent phrenic nerve palsy is the most frequent complication of cryoballoon ablation for atrial fibrillation and can be disabling. To describe a technique-immediate balloon deflation (IBD)-for the prevention of persistent phrenic nerve palsy, provide data for its use, and describe in vitro simulations performed to investigate the effect of IBD on the atrium and pulmonary vein. Cryoballoon procedures for atrial fibrillation were analyzed retrospectively (n = 130). IBD was performed in patients developing phrenic nerve dysfunction (n = 22). In vitro simulations were performed by using phantoms. No adverse events occurred, and all patients recovered normal phrenic nerve function before leaving the procedure room. No patient developed persistent phrenic nerve palsy. The mean cryoablation time to onset of phrenic nerve dysfunction was 144 ± 64 seconds. Transient phrenic nerve dysfunction was seen more frequently with the 23-mm balloon than with the 28-mm balloon (11 of 39 cases vs 11 of 81 cases; P = .036). Balloon rewarming was faster following IBD. The time to return to 0 and 20° C was shorter in the IBD group (6.7 vs 8.9 seconds; P = .007 and 16.7 vs 37.6 seconds; Pphrenic nerve palsy. Simulations suggest that IBD is unlikely to damage the atrium or pulmonary vein. Copyright © 2013 Heart Rhythm Society. All rights reserved.

  9. Gondola development for CNES stratospheric balloons

    Science.gov (United States)

    Vargas, A.; Audoubert, J.; Cau, M.; Evrard, J.; Verdier, N.

    The CNES has been supporting scientific ballooning since its establishment in 1962. The two main parts of the balloon system or aerostat are the balloon itself and the flight train, comprising the house-keeping gondola, for the control of balloon flight (localization and operational telemetry & telecommand - TM/TC), and the scientific gondola with its dedicated telecommunication system. For zero pressure balloon, the development of new TM/TC system for the housekeeping and science data transmission are going on from 1999. The main concepts are : - for balloon house-keeping and low rate scientific telemetry, the ELITE system, which is based on single I2C bus standardizing communication between the different components of the system : trajectography, balloon control, power supply, scientific TM/TC, .... In this concept, Radio Frequency links are developed between the house keeping gondola and the components of the aerostat (balloon valve, ballast machine, balloon gas temperature measurements, ...). The main objectives are to simplify the flight train preparation in term of gondola testing before flight, and also by reducing the number of long electrical cables integrated in the balloon and the flight train; - for high rate scientific telemetry, the use of functional interconnection Internet Protocol (IP) in interface with the Radio Frequency link. The main idea is to use off-the-shelf IP hardware products (routers, industrial PC, ...) and IP software (Telnet, FTP, Web-HTTP, ...) to reduce the development costs; - for safety increase, the adding, in the flight train, of a totally independent house keeping gondola based on the satellite Inmarsat M and Iridium telecommunication systems, which permits to get real time communications between the on-board data mobile and the ground station, reduced to a PC computer with modem connected to the phone network. These GEO and LEO telecommunication systems give also the capability to operate balloon flights over longer distance

  10. Weather Balloon Ascent Rate

    Science.gov (United States)

    Denny, Mark

    2016-05-01

    The physics of a weather balloon is analyzed. The surprising aspect of the motion of these balloons is that they ascend to great altitudes (typically 35 km) at a more or less constant rate. Such behavior is not surprising near the ground—say for a helium-filled party balloon rising from street level to the top of the Empire State building—but it is unexpected for a balloon that rises to altitudes where the air is rarefied. We show from elementary physical laws why the ascent rate is approximately constant.

  11. Revolving Classroom Door: Management Strategies To Eliminate the Quick Spin.

    Science.gov (United States)

    Rancifer, Jesse L.

    This paper presents classroom management practices that can be used to avoid the "revolving classroom door." In the revolving classroom door, misbehaving students are sent to the principal, and eventually returned to the classroom with no gains in student behavior or opportunity for learning. The paper begins by discussing the meaning of classroom…

  12. An investigation of electrostatically deposited radionuclides on latex balloons

    International Nuclear Information System (INIS)

    Price, T.; Caly, A.

    2012-01-01

    Use of Canadian Nuclear Society (CNS) education material for a community science education event to promote science awareness, science culture and literacy (Science Rendezvous 2011) lead to investigation of observed phenomena. Experiments are done on balloons that are electrostatically charged then left to collect particulate. Alpha spectroscopy was performed to identify alpha emitting radioisotopes present on the balloons. The time dependent behaviour of the activity was investigated. Additionally, the Alpha activity of the balloon was compared to Beta activity. The grounds for further investigations are proposed. (author)

  13. An investigation of electrostatically deposited radionuclides on latex balloons

    Energy Technology Data Exchange (ETDEWEB)

    Price, T.; Caly, A., E-mail: Terry.Price@gmail.com [Univ. of Ontario Inst. of Technology, Oshawa, Ontario (Canada)

    2012-07-01

    Use of Canadian Nuclear Society (CNS) education material for a community science education event to promote science awareness, science culture and literacy (Science Rendezvous 2011) lead to investigation of observed phenomena. Experiments are done on balloons that are electrostatically charged then left to collect particulate. Alpha spectroscopy was performed to identify alpha emitting radioisotopes present on the balloons. The time dependent behaviour of the activity was investigated. Additionally, the Alpha activity of the balloon was compared to Beta activity. The grounds for further investigations are proposed. (author)

  14. OCT evaluation of directional atherectomy compared to balloon angioplasty

    International Nuclear Information System (INIS)

    Marmagkiolis, Konstantinos; Lendel, Vasili; Cilingiroglu, Mehmet

    2015-01-01

    Directional atherectomy (DA) is one of the most commonly used modalities for the treatment of obstructive femoropopliteal peripheral arterial disease (PAD), especially in patients with large and calcified atherosclerotic plaques. The effect of directional atherectomy to the vascular wall compared to balloon angioplasty by optical coherence tomography (OCT) has not been previously described. We present the first case of OCT after directional atherectomy with SilverHawk followed by angiosculpt balloon angioplasty. - Highlights: • Directional atherectomy avoids the vascular mechanical damage caused by angioplasty balloons and the exposure of stent struts or the potential of stent fracture with stents. • OCT can accurately assess the effect of endovacular interventions to the vessel wall. • Although angiographic results after directional atherectomy are acceptable, OCT use demonstrated suboptimal improvement of the MLA requiring additional balloon angioplasty. • Longer studies are needed to define whether the improved OCT results with angioplasty compared to DA may offer better clinical outcomes.

  15. OCT evaluation of directional atherectomy compared to balloon angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Marmagkiolis, Konstantinos [Citizens Memorial Hospital Heart and Vascular Institute, Bolivar, MO (United States); Lendel, Vasili [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Cilingiroglu, Mehmet, E-mail: mcilingiroglu@yahoo.com [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Koc University, School of Medicine, Istanbul (Turkey)

    2015-09-15

    Directional atherectomy (DA) is one of the most commonly used modalities for the treatment of obstructive femoropopliteal peripheral arterial disease (PAD), especially in patients with large and calcified atherosclerotic plaques. The effect of directional atherectomy to the vascular wall compared to balloon angioplasty by optical coherence tomography (OCT) has not been previously described. We present the first case of OCT after directional atherectomy with SilverHawk followed by angiosculpt balloon angioplasty. - Highlights: • Directional atherectomy avoids the vascular mechanical damage caused by angioplasty balloons and the exposure of stent struts or the potential of stent fracture with stents. • OCT can accurately assess the effect of endovacular interventions to the vessel wall. • Although angiographic results after directional atherectomy are acceptable, OCT use demonstrated suboptimal improvement of the MLA requiring additional balloon angioplasty. • Longer studies are needed to define whether the improved OCT results with angioplasty compared to DA may offer better clinical outcomes.

  16. External caps: An approach to stress reduction in balloons

    Science.gov (United States)

    Hazlewood, K. H.

    Recent findings of the catastrophic balloon failures investigation in the U.S.A. indicate that very large gross inflations, in balloons using present design philosophy, over-stress currently available materials. External caps are proposed as an economic approach to reducting those stresses to an acceptable level.

  17. Fluoroscopy-guided balloon dilation in patients with Eustachian tube dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kun Yung; Tsauo, Jiaywei; Song, Ho-Young [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Park, Hong Ju; Kang, Woo Seok [University of Ulsan College of Medicine, Department of Otorhinolaryngology-Head and Neck Surgery, Asan Medical Center, Seoul (Korea, Republic of); Park, Jung-Hoon [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); University of Ulsan College of Medicine, Department of Biomedical Engineering Research Center, Asan Medical Center, Seoul (Korea, Republic of); Wang, Zhe [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Tianjin Medical University General Hospital, Department of Radiology (China)

    2018-03-15

    To prospectively evaluate the technical feasibility and safety of fluoroscopy-guided balloon dilation in patients with Eustachian tube (ET) dysfunction. Patients who could not do a Valsalva manoeuvre for more than 6 months and diagnosed with chronic otitis media or ET dysfunction were prospectively enrolled. A 0.035-in. guide wire and 6-mm long balloon catheter with a diameter of 2 mm were used to dilate the cartilaginous portion of the ET under fluoroscopic guidance. The balloon was inflated by manual injection twice for 1 min each time. Clinical outcomes were assessed by the patient's ability to perform a Valsalva manoeuvre, and symptoms were assessed using the 7-item Eustachian Tube Dysfunction Questionnaire (ETDQ-7) score. Balloon dilation was attempted in a total of ten adult patients from October 2016 to March 2017. Technical success was achieved in all procedures (10/10). Ninety percent (9/10) of the balloons were fully dilated without waist deformity. There were no major complications. All patients were able to perform a Valsalva manoeuvre at the time of their last visit and/or improvement of at least one ETDQ-7 score. Fluoroscopy-guided balloon dilation seems to be technically feasible and safe in the treatment of ET dysfunction. (orig.)

  18. Status of the NASA Balloon Program

    Science.gov (United States)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-02-01

    In the early 1980's the U.S. National Aeronautics and Space Administration (NASA) Balloon Program was faced with a problem of catastrophic balloon failures. In 1986 a balloon recovery program was initiated. This program included qualification of new balloon films, and investigations into materials, processing, structures and performance of balloons. This recovery program has been very successful. To date, more than 100 balloons manufactured of newly developed films have been flown with unprecedented success. There has been much progress made across the spectrum of balloon related disciplines. A new design philosophy has been developed and is being used for all NASA balloons. An updated balloon reliability and quality assurance program is in effect. The long duration balloon development project has been initiated with the first flight test having been conducted in December 1989 from Antarctica. A comprehensive research and development (R&D) effort has been initiated and is progressing well. The progress, status and future plans for these and other aspects of the NASA program, along with a description of the comprehensive balloon R&D activity, will be presented.

  19. The ballooning of fuel cladding tubes: theory and experiment

    International Nuclear Information System (INIS)

    Shewfelt, R.S.W.

    1988-01-01

    Under some conditions, fuel clad ballooning can result in considerable strain before rupture. If ballooning were to occur during a loss-of-coolant accident (LOCA), the resulting substantial blockage of the sub-channel would restrict emergency core cooling. However, circumferential temperature gradients that would occur during a LOCA may significantly limit the average strain at failure. Understandably, the factors that control ballooning and rupture of fuel clad are required for the analysis of a LOCA. Considerable international effort has been spent on studying the deformation of Zircaloy fuel cladding under conditions that would occur during a LOCA. This effort has established a reasonable understanding of the factors that control the ballooning, failure time, and average failure strain of fuel cladding. In this paper, both the experimental and theoretical studies of the fuel clad ballooning are reviewed. (author)

  20. Effects of Door Width and Human Body Size on Walking Speed

    Directory of Open Access Journals (Sweden)

    Jetthumrong Siwalee

    2016-01-01

    Full Text Available Door width is one of the important factors to concern in layout or facilities design because it affects directly to traffic speed and overall traffic time simultaneously. Nowadays, common assessment method is computer simulation which is still not realistic due to the unchanged speed of model while walking through a door. This research aims to study an effect of door width to individual walking speed. Sixty subjects participated in the experiment and performed task by walking through the door that is set the width as 40, 50, 60, 70, 80, 90 and 100 centimetres. The optical motion capture system was used to determine walking speed. The results showed that Fitts’ law was applied to the participants with high weight. Door width below 70 centimetres significantly affected to changing speed at 0-0.5 m. before the door. Additionally, human size also affected changing speed. The factors include shoulder breadth, weight and interaction between shoulder breadth and weight were found to be significant. These factors explained 54.2% of changing speed.

  1. Analysis of the quality of the whole journey (door-to-door) passenger expierence

    Energy Technology Data Exchange (ETDEWEB)

    Herrero Tomas, M.D.; Gonzalez Viosca, E.

    2016-07-01

    European cities increasingly face problems caused by transport and traffic. A key factor for all transport operators is the quality of the passenger experience as this particularly, affects the uptake of the service. A comprehensive study (METPEX FP7 EU project - www.metpex.eu) developed by a consortium of 16 European partners has analysed the quality of the whole journey (door-to-door) passenger experience, including private or individual forms transport and attending to specific need of users’ groups. For this purpose, a tool with a technological basis was used to collect data from 8 trial cities: Bucharest (Romania), Coventry (United Kingdom), Dublin (Ireland), Grevena (Greece), Rome (Italy), Stockholm (Sweden), Valencia (Spain) and Vilnius (Lithuania); and five FIA motorist networks countries. For a correct evaluation of quality experience, it was deployed a subset of key variables derived from the comprehensive set of potential satisfaction factors that were studied for each pilot city. In this paper, results of the travel experience are showed, including analysis of variables affecting behavior and feelings of passengers. (Author)

  2. Science Opens Doors

    Science.gov (United States)

    Smyth, Steve; Smyth, Jen

    2016-01-01

    Science Opens Doors is the creation of Clive Thompson of the Horners' Livery Company. The Science Opens Doors project philosophy is strongly based upon the King's College London ASPIRES project, which established that children like doing science in junior school (ages 7-11), but that by the age of 12-14 they are firmly against becoming scientists.…

  3. Aviation investigation report : hard landing : fuel leak and fire[Sundance Balloons International Firefly 12B (hot air balloon) C-FNVM, Winnipeg, Manitoba, 15 nm NE, 11 August 2007

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-08-15

    This investigation report discussed an incident in Winnipeg in which a hot air balloon attempting to land during strong winds was dragged on its side for approximately 700 feet. The balloon's burners struck the ground as the balloon came to a stop, after which a propane leak occurred. An intense, uncontrolled fire ensued as balloon passengers were exiting from the partially-inverted basket. The pilot and 2 passengers suffered serious injuries, while another 4 passengers suffered minor injuries. The balloon's 2 propane tanks and a fire extinguisher canister exploded during the fire, which destroyed the balloon's basket. The rigging of the balloon was examined and no failures were discovered. Pressure tests showed that the balloon's hoses started leaking at the crimped sleeve fittings at 150 psi. While the pilot had been informed of potentially heavy winds and thunderstorms, changes in wind speed and direction occurred earlier than the forecasted time of 10:00. It was concluded that standards are needed to ensure balloon cabin safety. Balloon operators do not currently require the use of protective helmets or gloves in case of dragged landings. A review will be conducted to address the issue of proposed emergency fuel shut-offs for balloons carrying fare-paying passengers. 2 figs.

  4. A new approach to the diagnosis of esophageal rupture due to balloon dilatation

    International Nuclear Information System (INIS)

    Song, Ho Young; Han, Young Min; Lee, Sang Young; Kuh, Ja Hong; Lee, Dong Kun; Chae, Soo Wan

    1990-01-01

    The diagnosis of esophageal rupture in balloon dilatation is usually made from clinical symptom of sharp chest pain, plain chest radiographs and esophagograms after dilation. It has some problems; the pain is varied patients to patients and bacterial flora in the mouth or esophagus can be mixed with the contrast media to flow into the mediastinum during esophagography, to create mediastinitis. We could make the diagnosis of esophageal rupture without using contrast media by the observation of the pressure change in the balloon during dilatation. An infusion pump, transducer and esophageal balloon were connected through a multi-way connector, and the transducer of them was also connected to an amplifier which was connected to a pressure monitor to record the balloon pressure. As balloon(20mm/3cm) inserted in the mid-thoracic esophagus under the fluoroscopic control was inflated until the esophagus was ruptured. Balloon was distended by injecting air in 15 rabbits(A group), and by injecting diluted contrast medium in 15 rabbits(B group). The pressure decrease after esophageal rupture was ranged from 94 to 160 mmHg(mean; 103) in A group and 340 to 1040 mmHg(mean; 537) in B group. The pressure curve of A group was smooth, regular and so accurate to make the diagnosis of esophageal rupture, whereas that of B group was irregular and not so accurate. In conclusion, our new method to make the diagnosis of esophageal rupture during balloon dilatation may be useful in patients of esophageal stricture

  5. Ballooning mode instability due to slowed-down ALPHA -particles and associated transport

    International Nuclear Information System (INIS)

    Itoh, Sanae; Itoh, Kimitaka; Tuda, Takashi; Tokuda, Shinji.

    1982-01-01

    The microscopic stability of tokamak plasma, which contains slowed-down alpha-particles and the anomalous fluxes enhanced by the fluctuation, was studied. The local maxwellian distribution with the density inhomogeneity as the equilibrium distribution of electrons, ions and alpha-particles was closen. In the zero-beta limit, two branches of eigenmodes, which are electrostatic, were obtained. The electrostatic ballooning mode became unstable by the grad B drift of particles in the toroidal plasma. It should be noted that there was no critical alpha-particle density and no critical beta-value for the onset of the instability in toroidal plasma even in the presence of the magnetic shear. When the beta-value exceeded the critical beta-value of the MHD ballooning mode, the growth rate approached to that of the MHD mode, and the mode sturcture became very close to that of the MHD mode. The unstable mode in toroidal plasma was the ballooning mode, and was unstable for all plasma parameters. The associated cross-field transport by the ballooning mode is considered. It was found that if the distribution function was assumed to be the birth distribution, the loss rate was very slow and slower than the slowing down time. The effect of alpha-particles on the large scale MHD activity of plasma is discussed. (Kato, T.)

  6. EMPLACEMENT DRIFT ISOLATION DOOR CONTROL SYSTEM

    International Nuclear Information System (INIS)

    N.T. Raczka

    1998-01-01

    The purpose of this analysis is to review and refine key design concepts related to the control system presently under consideration for remotely operating the emplacement drift isolation doors at the potential subsurface nuclear waste repository at Yucca Mountain. This analysis will discuss the key design concepts of the control system that may be utilized for remotely monitoring, opening, and closing the emplacement drift isolation doors. The scope and primary objectives of this analysis are to: (1) Discuss the purpose and function of the isolation doors (Presented in Section 7.1). (2) Review the construction of the isolation door and other physical characteristics of the doors that the control system will interface with (Presented in Section 7.2). (3) Discuss monitoring and controlling the operation of the isolation doors with a digital control system (either a Programmable Logic Controller (PLC) system or a Distributed Control System (DCS)) (Presented in Section 7.3). (4) Discuss how all isolation doors can be monitored and controlled from a subsurface central control center (Presented in Section 7.4). This analysis will focus on the development of input/output (I/O) counts including the types of I/O, redundancy and fault tolerance considerations, and processor requirements for the isolation door control system. Attention will be placed on operability, maintainability, and reliability issues for the system operating in the subsurface environment with exposure to high temperatures and radiation

  7. Door Locking Options in Schools

    Science.gov (United States)

    National Clearinghouse for Educational Facilities, 2009

    2009-01-01

    Doors serve a variety of needs and purposes in schools: (1) Exterior doors provide building security and protection from the elements; and (2) Interior doors control the movement of people among school spaces, help control noise and air flow, and act as flame and smoke barriers during a fire. In a lockdown, they serve as safety barriers. From a…

  8. Scientific Ballooning in India - Recent Developments

    Science.gov (United States)

    Manchanda, R. K.; Srinivasan, S.; Subbarao, J. V.

    Established in 1972, the National Balloon Facility operated by TIFR in Hyderabad, India is is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, Research and Development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is a hallmark of the Hyderabad balloon facility. In the past few years we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to size of 780,000 M^3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  9. Balloon-Expandable Stent Graft for Treating Uretero-Iliac Artery Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Guntau, Moritz, E-mail: guntau@med.uni-marburg.de [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hegele, Axel [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Rheinheimer, Stephan [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hofmann, Rainer [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Mahnken, Andreas H. [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany)

    2017-06-15

    PurposeTo evaluate the safety, efficacy and outcome of percutaneous balloon-expandable covered stent graft placement for uretero-iliac artery fistula (UAF) treatment.MethodsThis retrospective study evaluated the single-center experience of percutaneous balloon-expandable covered stent graft placement (ADVANTA™, Atrium Hudson, NH, USA) in UAF. Data were obtained from a prospective institutional database. Patient follow-up included complications, symptoms recurrence and mortality rate.ResultsTen UAFs in eight patients (3 males; 5 females) with a mean age of 64.5 (35–77) years were identified. All patients had a history pelvic malignancy, extirpative surgery (n = 6), long-term ureteral stenting (n = 7) and pelvic radiation (n = 5). All procedures were completed successfully without complications. Thirty-day mortality rate was zero. At a median follow-up of 6 (1–60) months, one patient suffered recurrent hematuria requiring a secondary stent graft placement 26 months after the initial treatment. During follow-up, five patients died of the underlying disease (43, 66, 105, and 183 and 274 days after the last procedure).ConclusionPercutaneous balloon-expandable stent graft placement in UAF is a safe and effective treatment option. Implantation of stent grafts should be considered as treatment of choice in UAF.

  10. Ballooning for Biologists: Mission Essentials for Flying Experiments on Large NASA Balloons

    Science.gov (United States)

    Smith, David J.; Sowa, Marianne

    2017-01-01

    Despite centuries of scientific balloon flights, only a handful of experiments have produced biologically-relevant results. Yet unlike orbital spaceflight, it is much faster and cheaper to conduct biology research with balloons, sending specimens to the near space environment of Earths stratosphere. Samples can be loaded the morning of a launch and sometimes returned to the laboratory within one day after flying. The National Aeronautics and Space Administration (NASA) flies large, unmanned scientific balloons from all over the globe, with missions ranging from hours to weeks in duration. A payload in the middle portion of the stratosphere (approx. 35 km above sea level) will be exposed to an environment similar to the surface of Mars: temperatures generally around -36 C, atmospheric pressure at a thin 1 kPa, relative humidity levels <1%, and a harsh illumination of ultraviolet (UV) and cosmic radiation levels (about 100 W/sq m and 0.1 mGy/d, respectively) that can be obtained nowhere else on the surface of the Earth, including environmental chambers and particle accelerator facilities attempting to simulate space radiation effects. Considering the operational advantages of ballooning and the fidelity of space-like stressors in the stratosphere, researchers in aerobiology, astrobiology, and space biology can benefit from balloon flight experiments as an intermediary step on the extraterrestrial continuum (ground, low Earth orbit, and deep space studies). Our presentation targets biologists with no background or experience in scientific ballooning. We will provide an overview of large balloon operations, biology topics that can be uniquely addressed in the stratosphere, and a roadmap for developing payloads to fly with NASA.

  11. Reducing Door-to-Needle Times using Toyota’s Lean Manufacturing Principles and Value Stream Analysis

    Science.gov (United States)

    Ford, Andria L.; Williams, Jennifer A.; Spencer, Mary; McCammon, Craig; Khoury, Naim; Sampson, Tomoko; Panagos, Peter; Lee, Jin-Moo

    2012-01-01

    Background Earlier tPA treatment for acute ischemic stroke increases efficacy, prompting national efforts to reduce door-to-needle times (DNTs). We utilized lean process improvement methodology to develop a streamlined IV tPA protocol. Methods In early 2011, a multi-disciplinary team analyzed the steps required to treat acute ischemic stroke patients with IV tPA, utilizing value stream analysis (VSA). We directly compared the tPA-treated patients in the “pre-VSA” epoch to the “post-VSA” epoch with regard to baseline characteristics, protocol metrics, and clinical outcomes. Results The VSA revealed several tPA protocol inefficiencies: routing of patients to room, then to CT, then back to room; serial processing of work flow; and delays in waiting for lab results. On 3/1/2011, a new protocol incorporated changes to minimize delays: routing patients directly to head CT prior to patient room, utilizing parallel process work-flow, and implementing point-of-care labs. In the pre-and post-VSA epochs, 132 and 87 patients were treated with IV tPA, respectively. Compared to pre-VSA, DNTs and percent of patients treated ≤60 minutes from hospital arrival were improved in the post-VSA epoch: 60 min vs. 39 min (pLean process improvement methodology can expedite time-dependent stroke care, without compromising safety. PMID:23138440

  12. Oesophageal strictures caused by the ingestion of corrosive agents: effectiveness of balloon dilatation in children

    Energy Technology Data Exchange (ETDEWEB)

    Doo, E.-Y. [Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of); Shin, J.H. [Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of)], E-mail: jhshin@amc.seoul.kr; Kim, J.H.; Song, H.-Y. [Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of)

    2009-03-15

    Aim: To evaluate the safety and clinical effectiveness of balloon dilatation in children for oesophageal strictures caused by the ingestion of corrosive agents. Materials and methods: The study comprised 11 children (median age 6 years; range 1-14 years) with oesophageal strictures caused by corrosive agents, who underwent a total of 36 balloon dilatation sessions. The technical and clinical success, recurrence of dysphagia, complications, and primary and secondary patency rates were retrospectively evaluated. Results: Technical success was achieved in 91% of patients and in 97% of balloon dilatation sessions. Clinical success (defined as improved food intake and reduced dysphagia within 1 month of the first balloon dilatation session) was achieved in 64% of patients (7/11). During the mean 35-month follow-up period (range 1-89 months), 10 (91%) patients experienced recurrence. Oesophageal rupture (types 1 or 2) occurred in 45% of patients and in 31% of balloon dilatation sessions. Primary patency rates at 6 months and 1, 2, 3, 4, and 5 years were 36, 27, 14, 14, 14, and 14%, respectively. Secondary patency rates at 6 months and 1, 2, 3, 4, and 5 years were 82, 82, 82, 56, 42, and 42%, respectively. The secondary patency rate was higher than the primary patency rate (p < 0.05). Conclusion: The present study examined oesophageal balloon dilatation for paediatric oesophageal strictures caused by the ingestion of corrosive agents. Although the technical success rate was high and there were no deaths, the clinical success rate was low owing to a high recurrence rate. However, repeated balloon dilatations resulted in an acceptable secondary patency rate.

  13. Barriers to and enablers for European rail freight transport for integrated door-to-door logistics service. Part 2: Enablers for multimodal rail freight transport

    Directory of Open Access Journals (Sweden)

    Dewan Md Zahurul ISLAM

    2014-12-01

    Full Text Available The objective of this paper is to examine and identify barriers to and enablers for the European rail freight transport services as a transport chain partner along the supply chains in the changing market scenario. The changing market scenario includes, among others, requiring 'door-to-door' rather than 'terminal to terminal' and integrated service, competitive ability to attract non-rail cargo type, changes in the customer requirements (e.g. reliable service and changes in the operational requirements and practices. Using a literature review method, the paper is presented in two parts. The part 1 focuses on the identification of barriers to the European rail freight service by reviewing freight logistics services for global supply chains followed by the current performance of European rail freight transport followed by a discussion on the rail freight market liberalisation in Europe. Then rail freight transport in the Unites States (U.S. is discussed. The research notes that although the background, scope and necessity for reform measures in Europe differ from those of the U.S., some lessons can be learned and the main lesson is that an appropriate reform measure can enhance rail sector competitive ability in Europe. The part 2 of the paper is dedicated to recommend some concrete steps and actions as enablers to remove the barriers identified in the part 1 to develop multimodal rail freight transport. The enablers for multimodal rail freight transport include: •\tEuropean rail freight transport market needs full liberalisation so that incumbent and new entrants can compete freely. •\tThe rail operators need to acquire service (e.g. customer tailored services, door to door service quality offered by road freight operators. •\tThey need to conduct a combination of ‘terminal-to-terminal’ and door-to-door operations, as and when needed; •\tThey must build partnership with freight forwarder or 3PLs to include all types of customers

  14. Scientific ballooning in India Recent developments

    Science.gov (United States)

    Manchanda, R. K.

    Established in 1971, the National Balloon Facility operated by TIFR in Hyderabad, India, is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, research and development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is its hallmark. In the past few years, we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m 3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  15. 21 CFR 874.4100 - Epistaxis balloon.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Epistaxis balloon. 874.4100 Section 874.4100 Food... DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4100 Epistaxis balloon. (a) Identification. An epistaxis balloon is a device consisting of an inflatable balloon intended to control internal...

  16. Ballooning stability analysis of JET H-mode discharges

    International Nuclear Information System (INIS)

    O'Brien, D.P.; Galvao, R.; Keilhacker, M.; Lazzaro, E.; Watkins, M.L.

    1989-01-01

    Previous studies of the stability of a large aspect ratio model equilibrium to ideal MHD ballooning modes have shown that across the bulk of the plasma there exist two marginally stable values of the pressure gradient parameter α. These define an unstable zone which separates the first (small α) stable region from the second (large α) stable region. Close to the separatrix, however, the first and second regions can coalesce when the surface averaged current density, Λ, exceeds a critical value. The plasma in this region is then stable to ballooning modes at all values of the pressure gradient. In this paper we extend these results to JET H-mode equilibria using a finite aspect ratio ballooning formalism, and assess the relevance of ideal ballooning stability in these discharges. In particular we analyse shot 15894 at time 56 sec. which is 1.3 s into the H-phase. (author) 4 refs., 4 figs

  17. Rectal Balloon for the Immobilization of the Prostate Internal Motion

    International Nuclear Information System (INIS)

    Lee, Sang Kyu; Beak, Jong Geal; Kim, Joo Ho; Jeon, Byong Chul; Cho, Jeong Hee; Kim, Dong Wook; Song, Tae Soo; Cho, Jae Ho; Na, Soo Kyong

    2005-01-01

    The using of endo-rectal balloon has proposed as optimal method that minimized the motion of prostate and the dose of rectum wall volume for treated prostate cancer patients, so we make the customized rectal balloon device. In this study, we analyzed the efficiency of the Self-customized rectal balloon in the aspects of its reproducibility. In 5 patients, for treatment planning, each patient was acquired CT slice images in state of with and without rectal balloon. Also they had CT scanning same repeated third times in during radiation treatment (IMRT). In each case, we analyzed the deviation of rectal balloon position and verified the isodose distribution of rectum wall at closed prostate. Using the rectal balloon, we minimized the planning target volume (PTV) by decreased the internal motion of prostate and overcome the dose limit of radiation therapy in prostate cancer by increased the gap between the rectum wall and high dose region. The using of rectal balloon, although, was reluctant to treat by patients. View a point of immobilization of prostate internal motion and dose escalation of GTV (gross tumor volume), its using consider large efficient for treated prostate cancer patients.

  18. Close-fitting shield doors with sculptured edges

    International Nuclear Information System (INIS)

    Goodman, L.

    1986-01-01

    The US Department of Energy has contracted with Fluor Technology, Inc. for design and engineering of a facility to begin reprocessing fuel from the reactors at Hanford, Washington. Within the facility, a 15-cm (6-in.)-thick, steel shield door is needed to close an opening 4.3 m (14 ft) high x 8.2 m (27 ft) wide. Two cranes and a centrally located monorail hoist must pass through the opening. The door weighs about 41,000 kg (45 ton), and passage of the hoist will be the most frequent cause for opening the door. These two factors essentially mandated a three-piece door, which allows for using commercially available chain hoists to raise and lower the individual door sections. Normally, there is a 187-Pa (0.75-in. water gauge) pressure differential across the door, and minimal air leakage is essential. Stepped, mating edges between sections and along the adjacent concrete structures are typical with such doors, but so are significant gaps (and air leaks) around the edges. Gaps are needed to preclude frictional jamming between edges as a section is lowered. The challenge was to conceive a method to produce near-zero gaps and preclude jamming without involving impractically tight tolerances. The chosen method was to place trapezoidally shaped, steel gaskets on the door-section edges and on the mating concrete surfaces. The concept is described

  19. SBARMO-79 a multi-balloon campaign in the auroral zone

    International Nuclear Information System (INIS)

    Tanskanen, P.; Kangas, J.; Bjordal, J.; Bronstad, K.; Block, L.P.; Holtet, T.

    1982-01-01

    A joint European International Magnetospheric Study (IMS) balloon campaign was conducted within the framework of the Scientific Ballooning and Radiation Monitoring Organization (SBARMO). The campaign was carried out during the time from May 30 to July 10, 1979. A total of 29 successful balloon launches were made from four launch sites located in Norway and in Finland. The campaign has the objective to provide information for a better understanding of temporal and spatial variations of magnetospheric processes, giving particular attention to the coupling between the magnetosphere and the ionosphere

  20. Technologies developed by CNES balloon team

    Science.gov (United States)

    Sosa-Sesma, Sergio; Charbonnier, Jean-Marc; Deramecourt, Arnaud

    CNES balloon team develops and operates all the components of this kind of vehicle: it means envelope and gondola. This abstract will point out only developments done for envelope. Nowadays CNES offers to scientists four types of envelops that cover a large range of mission demands. These envelops are: 1. Zero pressure balloons: Size going from 3,000m3 to 600,000m3, this kind of envelop is ideal for short duration flights (a few hours) but if we use an intelligent management of ballast consumption and if we chose the best launch site, it is possible to perform medium duration flights (10/20 days depending on the ballast on board). Flight train mass starts at 50kg for small balloons and reach 1000kg for larger ones. Zero pressure balloons are inflated with helium gas. 2. Super pressure balloons: Diameter going from 2.5m to 12m, this kind of envelop is ideal for long duration flights (1 to 6 months). Flight train is inside the envelop for small balloons, it means 2.5 diameter meters which is usually called BPCL (Super pressure balloon for Earth boundary layer) and it is about 3kg of mass. Larger ones could lift external flight trains about 50kg of mass. Super pressure balloons are inflated with helium gas. 3. MIR balloons: Size going from 36,000m3 to 46,000m3. Ceiling is reach with helium gas but after three days helium is no longer present inside and lift force is produced by difference of temperature between air inside and air of atmosphere. Flight trains must not be over 50kg. 4. Aero Clipper balloons: A concept to correlate measurements done in oceans and in nearest layers of atmosphere simultaneously. Flight train is made by a "fish" that drags inside water and an atmospheric gondola few meters above "fish", both pushed by a balloon which profits of the wind force. Materials used for construction and assembling depend on balloon type; they are usually made of polyester or polyethylene. Thickness varies from 12 micrometers to 120 micrometers. Balloon assembling

  1. The Micro-Instrumentation Package: A Solution to Lightweight Ballooning

    Science.gov (United States)

    Juneau, Jill

    This paper discusses the design and testing of an over the horizon (OTH) light weight telemetry and termination system that can be used for small ballooning payloads. Currently, the Columbia Scientific Balloon Facility (CSBF) provides telemetry for the science payload by integrating one of two types of support packages. The type of support package integrated depends on whether the flight will stay in range of line of sight (LOS) or will exceed LOS requiring the use of over the horizon (OTH) telemetry. The weights of these systems range from 100 pounds to 350 pounds depending upon the use of redundant systems, equipment for high data rates, and batteries and/or solar panels for power requirements. These weight values are not as significant for larger payloads but can be crippling for smaller payloads. In addition, these support package systems are fairly expensive, placing a high importance on recovery. A lightweight and inexpensive telemetry system could be beneficial for various reasons. First, it would allow scientists to fly lightweight payloads on large balloons reaching even higher altitudes. Second, scientists could fly lightweight payloads on less expensive balloons such as meteorological balloons. Depending on the payload, these flights could be fairly inexpensive and even disposable. Third, a compact telemetry system on any balloon will free up more room for the science portion of the payload. In response, a compact telemetry/termination system called the Micro-Instrumentation Package (MIP) was developed. The MIP provides uplink and downlink communications, an interface to the science, housekeeping information including global positioning system (GPS) position, and relays. Instead of a power-hungry microprocessor, the MIP's central consists of a microcontroller. Microcontrollers are lower power, easily programmed, and can be purchased for less than ten dollars. For uplink and downlink telemetry, the MIP uses an LOS serial transceiver and an Iridium unit

  2. Design, development and testing of a high speed door for a blast containment fixture

    International Nuclear Information System (INIS)

    Shapiro, C.

    1991-01-01

    This paper reports that the concept of a large door able to close over a three foot diameter hole in less than 50 milliseconds evolved during the design of a test containment fixture at the Idaho National Engineering laboratory (INEL). This facility was designed for use at the Aberdeen Proving Ground (APG) in Aberdeen, Maryland. EPA regulations required new technologies for blast containment at APG, which culminated in the design of the blast chamber with a high speed door at its entrance. The main requirement of the fixture is to contain large explosion pressure pulses and explosive by-products during a variety of test scenarios. The door was designed to allow entrance of test projectiles and then to close over the entrance hole to contain explosive by-products inside the fixture. The speed of the projectile and the resultant blast pressure pulse required door closure within 56 msec. Analytical modelling of the door closure indicated velocities of up to 150 ft/sec before impact, for closure within the required time. Lightweight materials were used for the moving parts to minimize this impact force, including aluminum honeycomb composite panels and energy absorbers. Actuation was accomplished with a standard explosive bolt. High pressure nitrogen accelerated the door during closure. Time measurement for the door closer were obtained using high speed video equipment

  3. Cardiogenic shock with ST-segment elevation acute coronary syndrome (ReNa-Shock ST

    Directory of Open Access Journals (Sweden)

    Yanina Castillo Costa

    2017-08-01

    Full Text Available Cardiogenic shock (CS in the setting of an ST-segment elevation myocardial infarction (STEMI is a severe complication and constitutes one of the principal causes of death associated with this condition. The aim of this study was to describe the clinical characteristics, treatment strategies and hospital outcome of CS associated with STEMI in Argentina. The Argentine Registry of Cardiogenic Shock (ReNA-Shock was a prospective and multicenter registry of consecutive patients with CS hospitalized in 64 centers in Argentina between July 2013 and May 2015. Only those with ST-segment elevation myocardial infarction (STEMI were selected for this analysis. Of the 165 patients included in the ReNa-Shock registry, 124 presented STEMI. Median age was 64 years (IQR 25-75: 56.5-75 and 67% were men; median time from symptom onset to admission was 240 minutes (IQR 25-75: 132-720. 63% of the cases presented CS at admission. Eighty-seven percent underwent reperfusion therapy: 80% primary percutaneous intervention with a median door-to-balloon time of 110 minutes (IQR 25-75: 62-184. Inotropic agents were used in 96%; 79% required mechanical ventilation; a Swan Ganz catheter was inserted in 47% and 35% required intra-aortic balloon pumping. Most patients (59% presented multivessel disease (MV. Hospital mortality was 54%. Multivariate analysis identified that time from symptom onset to admission (> 240 min was the only independent predictor of mortality (OR: 3.04; CI 95%: 1.18-7.9. Despite using treatment strategies currently available, morbidity and mortality of STEMI complicated with CS remains high.

  4. Nuclear Storage Overpack Door Actuator and Alignment Apparatus

    International Nuclear Information System (INIS)

    Andreyko, Gregory M.

    2005-01-01

    The invention is a door actuator and alignment apparatus for opening and closing the 15,000-pound horizontally sliding door of a storage overpack. The door actuator includes a ball screw mounted horizontally on a rigid frame including a pair of door panel support rails. An electrically powered ball nut moves along the ball screw. The ball nut rotating device is attached to a carriage. The carriage attachment to the sliding door is horizontally pivoting. Additional alignment features include precision cam followers attached to the rails and rail guides attached to the carriage

  5. JACEE long duration balloon flights

    International Nuclear Information System (INIS)

    Burnett, T.; Iwai, J.; Lord, J.J.; Strausz, S.; Wilkes, R.J.; Dake, S.; Oda, H.; Miyamura, O.; Fuki, M.; Jones, W.V.; Gregory, J.; Hayashi, T.; Takahashi, U.; Tominaga, Y.; Wefel, J.P.; Fountain, W.; Derrickson, J.; Parnell, T.A.; Roberts, E.; Tabuki, T.; Watts, J.W.

    1989-01-01

    JACEE balloon-borne emulsion chamber detectors are used to observe the spectra and interactions of cosmic ray protons and nuclei in the energy range 1-100A TeV. Experience with long duration mid-latitude balloon flights and characteristics of the detector system that make it ideal for planned Antarctic balloon flights are discussed. 5 refs., 2 figs

  6. Design and Construction of Pool Door for Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kwangsub; Lee, Sangjin; Choi, Jinbok; Oh, Jinho; Lee, Jongmin [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The pool door is a structure to isolate the reactor pool from the service pool for maintenance. The pool door is installed before the reactor pool is drained. The pool door consists of structural component and sealing component. The main structures of the pool door are stainless steel plates and side frames. The plates and frames are assembled by welded joints. Lug is welded at the top of the plate. The pool door is submerged in the pool water when it is used. Materials of the pool door should be resistive to corrosion and radiation. Stainless steel is used in structural components and air nozzle assemblies. Features of design and construction of the pool door for the research reactor are introduced. The pool door is designed to isolate the reactor pool for maintenance. Structural analysis is performed to evaluate the structural integrity during earthquake. Tests and inspections are also carried out during construction to identify the safety and function of the pool door.

  7. Design and Construction of Pool Door for Research Reactor

    International Nuclear Information System (INIS)

    Jung, Kwangsub; Lee, Sangjin; Choi, Jinbok; Oh, Jinho; Lee, Jongmin

    2016-01-01

    The pool door is a structure to isolate the reactor pool from the service pool for maintenance. The pool door is installed before the reactor pool is drained. The pool door consists of structural component and sealing component. The main structures of the pool door are stainless steel plates and side frames. The plates and frames are assembled by welded joints. Lug is welded at the top of the plate. The pool door is submerged in the pool water when it is used. Materials of the pool door should be resistive to corrosion and radiation. Stainless steel is used in structural components and air nozzle assemblies. Features of design and construction of the pool door for the research reactor are introduced. The pool door is designed to isolate the reactor pool for maintenance. Structural analysis is performed to evaluate the structural integrity during earthquake. Tests and inspections are also carried out during construction to identify the safety and function of the pool door

  8. Pioneering Space Research with Balloons

    Science.gov (United States)

    Jones, W. V.

    NASA s Scientific Ballooning Planning Team has concluded that ballooning enables significant scientific discoveries while providing test beds for space instruments and training for young scientists Circumpolar flights around Antarctica have been spectacularly successful with fight durations up to 42 days Demand for participation in this Long-Duration Balloon LDB program a partnership with the U S National Science Foundation Office of Polar Programs is greater than the current capacity of two flights per campaign Given appropriate international agreements LDB flights in the Northern Hemisphere would be competitive with Antarctic flights and super-pressure balloons would allow comparable flights at any latitude The Balloon Planning Team made several recommendations for LDB flights provide a reliable funding source for sophisticated payloads extend the Antarctic capability to three flights per year and develop a comparable capability in the Arctic provide aircraft for intact-payload recovery develop a modest trajectory modification capability to enable longer flights and enhance super-pressure balloons to carry 1-ton payloads to 38 km Implementation of these recommendations would facilitate frequent access to near-space for cutting-edge research and technology development for a wide range of investigations

  9. Cutting-balloon angioplasty of resistant ureteral stenosis as bridge to stent insertion

    Energy Technology Data Exchange (ETDEWEB)

    Iezzi, R., E-mail: iezzir@virgilio.it [Department of Bioimaging and Radiological Sciences, Institute of Radiology, ' A. Gemelli' Hospital - Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Di Stasi, C.; Simeone, A.; Bonomo, L. [Department of Bioimaging and Radiological Sciences, Institute of Radiology, ' A. Gemelli' Hospital - Catholic University, L.go A Gemelli 8, 00168 Rome (Italy)

    2011-07-15

    Ureteral stenting is a routine, minimally invasive procedure performed for relief of benign or malignant obstruction. In case of ureteral stenosis, to allow a correct insertion of the stent, a predilatation of the ureter stenosis with a conventional balloon catheter can be necessary. In exceptional cases, it can be difficult to advance an 7-8 Fr JJ-catheter over a tight resistant ureter stenosis following unsuccessful high-pressure balloon dilatation. In the present report, we describe two cases of resistant ureter stenosis successfully dilated by a cutting-balloon following the failure of high-pressure balloon dilatation, allowing a correct and uncomplicated antegrade stent insertion.

  10. Cutting-balloon angioplasty of resistant ureteral stenosis as bridge to stent insertion

    International Nuclear Information System (INIS)

    Iezzi, R.; Di Stasi, C.; Simeone, A.; Bonomo, L.

    2011-01-01

    Ureteral stenting is a routine, minimally invasive procedure performed for relief of benign or malignant obstruction. In case of ureteral stenosis, to allow a correct insertion of the stent, a predilatation of the ureter stenosis with a conventional balloon catheter can be necessary. In exceptional cases, it can be difficult to advance an 7-8 Fr JJ-catheter over a tight resistant ureter stenosis following unsuccessful high-pressure balloon dilatation. In the present report, we describe two cases of resistant ureter stenosis successfully dilated by a cutting-balloon following the failure of high-pressure balloon dilatation, allowing a correct and uncomplicated antegrade stent insertion.

  11. Complications of balloon packing in epistaxis

    NARCIS (Netherlands)

    Vermeeren, Lenka; Derks, Wynia; Fokkens, Wytske; Menger, Dirk Jan

    2015-01-01

    Although balloon packing appears to be efficient to control epistaxis, severe local complications can occur. We describe four patients with local lesions after balloon packing. Prolonged balloon packing can cause damage to nasal mucosa, septum and alar skin (nasal mucosa, the cartilaginous skeleton

  12. Dynamic Object Oriented Requirements System (DOORS) System Test Plan

    International Nuclear Information System (INIS)

    JOHNSON, A.L.

    2000-01-01

    The U. S. Department of Energy, Office of River Protection (ORP) will use the Dynamic Object Oriented Requirements System (DOORS) as a tool to assist in identifying, capturing, and maintaining the necessary and sufficient set of requirements for accomplishing the ORP mission. By managing requirements as one integrated set, the ORP will be able to carry out its mission more efficiently and effectively. DOORS is a Commercial-Off-The-Shelf (COTS) requirements management tool. The tool has not been customized for the use of the PIO, at this time

  13. Development of a New Coaxial Balloon Catheter System for Balloon-Occluded Retrograde Transvenous Obliteration (B-RTO)

    International Nuclear Information System (INIS)

    Tanoue, Shuichi; Kiyosue, Hiro; Matsumoto, Shunro; Hori, Yuzo; Okahara, Mika; Kashiwagi, Junji; Mori, Hiromu

    2006-01-01

    Purpose. To develop a new coaxial balloon catheter system and evaluate its clinical feasibility for balloon-occluded retrograde transvenous obliteration (B-RTO). Methods. A coaxial balloon catheter system was constructed with 9 Fr guiding balloon catheter and 5 Fr balloon catheter. A 5 Fr catheter has a high flexibility and can be coaxially inserted into the guiding catheter in advance. The catheter balloons are made of natural rubber and can be inflated to 2 cm (guiding) and 1 cm (5 Fr) maximum diameter. Between July 2003 and April 2005, 8 consecutive patients (6 men, 2 women; age range 33-72 years, mean age 55.5 years) underwent B-RTO using the balloon catheter system. Five percent ethanolamine oleate iopamidol (EOI) was used as sclerosing agent. The procedures, including maneuverability of the catheter, amount of injected sclerosing agent, necessity for coil embolization of collateral draining veins, and initial clinical results, were evaluated retrospectively. The occlusion rate was assessed by postcontrast CT within 2 weeks after B-RTO. Results. The balloon catheter could be advanced into the proximal potion of the gastrorenal shunt beyond the collateral draining vein in all cases. The amount of injected EOI ranged from 3 to 34 ml. Coil embolization of the collateral draining vein was required in 2 cases. Complete obliteration of gastric varices on initial follow-up CT was obtained in 7 cases. The remaining case required re-treatment that resulted in complete obstruction of the varices after the second B-RTO. No procedure-related complications were observed. Conclusion. B-RTO using the new coaxial balloon catheter is feasible. Gastric varices can be treated more simply by using this catheter system

  14. Balloon sheaths for gastrointestinal guidance and access: a preliminary phantom study

    International Nuclear Information System (INIS)

    He, Xu; Shin, Ji Hoon; Kim, Hyo Cheol; Woo, Cheol Woong; Woo, Sung Ha; Choi, Won Chan; Kim, Jong Gyu; Lim, Jin Oh; Kim, Tae Hyung; Yoon, Chang Jin; Song, Ho Young; Kang, Wee Chang

    2005-01-01

    We wanted to evaluate the feasibility and usefulness of a newly designed balloon sheath for gastrointestinal guidance and access by conducting a phantom study. The newly designed balloon sheath consisted of an introducer sheath and a supporting balloon. A coil catheter was advanced over a guide wire into two gastroduodenal phantoms (one was with stricture and one was without stricture); group I was without a balloon sheath, group II was with a deflated balloon sheath, and groups III and IV were with an inflated balloon and with the balloon in the fundus and body, respectively. Each test was performed for 2 minutes and it was repeated 10 times in each group by two researchers, and the positions reached by the catheter tip were recorded. Both researchers had better performances with both phantoms in order of group IV, III, II and I. In group IV, both researchers advanced the catheter tip through the fourth duodenal segment in both the phantoms. In group I, however, the catheter tip never reached the third duodenal segment in both the phantoms by both the researchers. The numeric values for the four study groups were significantly different for both the phantoms (ρ < 0.001). A significant difference was also found between group III and IV for both phantoms (ρ < 0.001). The balloon sheath seems to be feasible for clinical use, and it has good clinical potential for gastrointestinal guidance and access, particularly when the inflated balloon is placed in the gastric body

  15. Use of Cutting Balloon in the Treatment of Urethral Stricture: A Novel Technique

    International Nuclear Information System (INIS)

    Yildirim, Erkan; Cicek, Tufan; Istanbulluoglu, Okan; Ozturk, Bulent

    2009-01-01

    The peripheral cutting balloon has been used to treat various nonvascular strictures as well as vascular stenosis. In this article, we describe for the first time the use of the cutting balloon in the treatment of patients with urethral stricture. Four patients with bulbar urethral stricture were included in the study. All strictures were successfully dilated with the cutting balloon, and patients were free of symptoms at 6-month follow-up. Cutting-balloon dilatation is a safe, easy-to-perform, and effective treatment for patients with tight urethral strictures.

  16. An unexpected knock on Corrigan's secret door.

    Science.gov (United States)

    Woywodt, Alexander

    2010-10-01

    Corrigan's secret door describes a metaphorical escape route for busy physicians. The term was derived from the successful and exceptionally busy professional life of Irish physician Dominic John Corrigan (1802-80). It is claimed that Corrigan's outpatient clinic was so busy that he required a secret door in his consulting rooms to escape from the ever-growing queue of eager patients. The origins of this charming story are unknown, and the door may have never existed. However, at present, Corrigan's secret door is often quoted when busy physicians have their own little ways in surviving a stressful professional life. Generations of British-trained doctors have grown up with Corrigan's secret door, as it was featured in the introduction of the Oxford Handbook of Clinical Medicine. Accordingly, trainees as well as more senior doctors are often reminded that having a 'secret door' is vital in surviving in the medical profession. My own escape is through classical music and the violoncello, in particular. As the name implies, my own secret door is normally invisible to colleagues and patients. This little article is about a patient who found me out, and a reflection on the role of classical music and the cello in my professional life.

  17. Recent Developments in Scientific Research Ballooning

    International Nuclear Information System (INIS)

    Jones, W. Vernon

    2007-01-01

    The National Aeronautics and Space Administration (NASA) Balloon Program is committed to meeting the need for extended duration scientific investigations by providing advanced balloon vehicles and support systems. A sea change in ballooning capability occurred with the inauguration of 8 - 20 day flights around Antarctica in the early 1990's. The attainment of 28-31 day flights and a record-breaking 42-day flight in, respectively, two and three circumnavigations of the continent has greatly increased the expectations of the scientific users. A new super-pressure balloon is currently under development for future flights of 60-100 days at any latitude, which would bring another sea change in scientific research ballooning

  18. Comparing energy use and environmental emissions of reinforced wood doors and steel doors

    Science.gov (United States)

    Lynn Knight; Melissa Huff; Janet I. Stockhausen; Robert J. Ross

    2005-01-01

    The USDA Forest Service Forest Products Laboratory has patented a technology that incorporates fiberglass-reinforced wood into the structure of wood doors and other wood building products. The process of reinforcing wood doors with epoxy and fiberglass increases the strength and durability of the product. Also, it allows the use of low-value, small-diameter wood which...

  19. OCT evaluation of directional atherectomy compared to balloon angioplasty.

    Science.gov (United States)

    Marmagkiolis, Konstantinos; Lendel, Vasili; Cilingiroglu, Mehmet

    2015-09-01

    Directional atherectomy (DA) is one of the most commonly used modalities for the treatment of obstructive femoropopliteal peripheral arterial disease (PAD), especially in patients with large and calcified atherosclerotic plaques. The effect of directional atherectomy to the vascular wall compared to balloon angioplasty by optical coherence tomography (OCT) has not been previously described. We present the first case of OCT after directional atherectomy with SilverHawk followed by angiosculpt balloon angioplasty. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. A balloon-borne prototype for demonstrating the concept of JEM-EUSO

    Science.gov (United States)

    von Ballmoos, P.; Santangelo, A.; Adams, J. H.; Barrillon, P.; Bayer, J.; Bertaina, M.; Cafagna, F.; Casolino, M.; Dagoret, S.; Danto, P.; Distratis, G.; Dupieux, M.; Ebersoldt, A.; Ebisuzaki, T.; Evrard, J.; Gorodetzky, Ph.; Haungs, A.; Jung, A.; Kawasaki, Y.; Medina-Tanco, G.; Mot, B.; Osteria, G.; Parizot, E.; Park, I. H.; Picozza, P.; Prévôt, G.; Prieto, H.; Ricci, M.; Rodríguez Frías, M. D.; Roudil, G.; Scotti, V.; Szabelski, J.; Takizawa, Y.; Tusno, K.

    2014-05-01

    EUSO-BALLOON has been conceived as a pathfinder for JEM-EUSO, a mission concept for a space-borne wide-field telescope monitoring the Earth's nighttime atmosphere with the objective of recording the ultraviolet light from tracks initiated by ultra-high energy cosmic rays. Through a series of stratospheric balloon flights performed by the French Space Agency CNES, EUSO-BALLOON will serve as a test-bench for the key technologies of JEM-EUSO. EUSO-BALLOON shall perform an end-to-end test of all subsystems and components, and prove the global detection chain while improving our knowledge of the atmospheric and terrestrial ultraviolet background. The balloon-instrument also has the potential to detect for the first time UV-light generated by atmospheric air-shower from above, marking a milestone in the development of UHECR science, and paving the way for any future large scale, space-based ultra-high energy cosmic ray observatory.

  1. Performance of the EUSO-Balloon electronics

    International Nuclear Information System (INIS)

    Barrillon, P.; Dagoret, S.; Miyamoto, H.; Moretto, C.; Bacholle, S.; Blaksley, C; Gorodetzky, P.; Jung, A.; Prévôt, G.; Prat, P.; Bayer, J.; Blin, S.; Taille, C. De La; Cafagna, F.; Fornaro, C.; Karczmarczyk, J.; Tanco, G. Medina; Osteria, G.; Perfetto, F.; Park, I.

    2016-01-01

    The 24th of August 2014, the EUSO-Balloon instrument went for a night flight for several hours, 40 km above Timmins (Canada) balloon launching site, concretizing the hard work of an important part of the JEM-EUSO collaboration started 3 years before. This instrument consists of a telescope made of two lenses and a complex electronic chain divided in two main sub-systems: the PDM (Photo Detector Module) and the DP (Data Processor). Each of them is made of several innovative elements developed and tested in a short time. This paper presents their performances before and during the flight

  2. Abdominal cavity balloon for preventing a patient's bleeding

    OpenAIRE

    Naber, E.E.H.; Rutten, H.J.T.; Jakimowicz, J.J.; Goossens, R.H.M.; Moes, C.C.M.; Buzink, S.N.

    2007-01-01

    The invention relates to an abdominal cavity balloon for preventing a haemorrhage in a patient's pelvic region, comprising an inflatable balloon, wherein the balloon is pro vided with a smooth surface and with a strip that is flex- urally stiff and formed to follow the balloon's shape for po sitioning the balloon.

  3. Development, Control, and Evaluation of an Actuated Car Door.

    Science.gov (United States)

    Strolz, M; Mortl, A; Graf, M; Buss, M

    2009-01-01

    Actuated car doors are a promising way to increase the convenience of access to cars. We propose an advanced actuation and control concept which can easily be integrated into conventional car doors. By utilizing a linear, nonbackdrivable actuator and various sensors, both automatic and manual door operations are enabled. A discrete state controller ensures a safe operation of the door, including automatic opening and closing. The realization of a supportive, high-quality haptic interaction with the car door for the manual operation is the principal part of our work. Due to the impracticality of a direct measurement of the user interaction force at a car door, we chose impedance control to render the desired dynamics. The impedance was designed to provide a convenient, intuitive, and safe manual handling of the door. We implemented and tested four different impedance control schemes, of which impedance control with actuator force feedback performed best. Two experimental evaluations with 16 and 27 participants revealed a predominant approval of the actuated car door.

  4. Launching Garbage-Bag Balloons.

    Science.gov (United States)

    Kim, Hy

    1997-01-01

    Presents a modification of a procedure for making and launching hot air balloons made out of garbage bags. Student instructions for balloon construction, launching instructions, and scale diagrams are included. (DDR)

  5. Solar research with stratospheric balloons

    Science.gov (United States)

    Vázquez, Manuel; Wittmann, Axel D.

    Balloons, driven by hot air or some gas lighter than air, were the first artificial machines able to lift payloads (including humans) from the ground. After some pioneering flights the study of the physical properties of the terrestrial atmosphere constituted the first scientific target. A bit later astronomers realized that the turbulence of the atmospheric layers above their ground-based telescopes deteriorated the image quality, and that balloons were an appropriate means to overcome, total or partially, this problem. Some of the most highly-resolved photographs and spectrograms of the sun during the 20th century were actually obtained by balloon-borne telescopes from the stratosphere. Some more recent projects of solar balloon astronomy will also be described.

  6. Modelling Hot Air Balloons.

    Science.gov (United States)

    Brimicombe, M. W.

    1991-01-01

    A macroscopic way of modeling hot air balloons using a Newtonian approach is presented. Misleading examples using a car tire and the concept of hot air rising are discussed. Pressure gradient changes in the atmosphere are used to explain how hot air balloons work. (KR)

  7. Calculating Payload for a Tethered Balloon System

    Science.gov (United States)

    Charles D. Tangren

    1980-01-01

    A graph method to calculate payload for a tethered balloon system, with the supporting helium lift and payload equations. is described. The balloon system is designed to collect emissions data during the convective-lift and no-convective-lift phases of a forest fire. A description of the balloon system and a list of factors affecting balloon selection are included....

  8. Ballooning stability of JET discharges

    International Nuclear Information System (INIS)

    Huysmans, G.T.A.; Goedbloed, J.P.; Galvao, R.M.O.; Lazzaro, E.; Smeulders, P.

    1989-01-01

    Conditions under which ballooning modes are expected to be excited have recently been obtained in two different types of discharges in JET. In the first type, extremely large pressure gradients have been produced in the plasma core through pellet injections in the current rise phase followed by strong additional heating. In the second type, the total pressure of the discharge is approaching the Troyon limit. The stability of these discharges with respect to the ideal MHD ballooning modes has been studied with the stability code HBT. The equilibria are reconstructed with the IDENTC code using the external magnetic measurements and the experimental pressure profile. The results show that the evaluated high beta discharge is unstable in the central region of the plasma. This instability is related to the low shear and not to a large pressure gradient, as expected at the Troyon limit. In the pellet discharges the regions with the large pressure gradients are unstable to ballooning modes at the time of the beta decay, which ends the period of enhanced performance. The maximum pressure gradient in these discharges is limited by the boundary of the first region of stability. The observed phenomena at the beta decay are similar to those observed at the beta limit in DIII-D and TFTR. (author)

  9. Modal analysis of pool door in water tank

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kang Soo; Jeong, Kyeong Hoon; Park, Chan Gook; Koo, In Soo [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    A pool door is installed at the chase of the pool gate by means of an overhead crane in the building of a research reactor. The principal function of the pool door, which is located between the reactor pool and service pool, is to separate the reactor pool from the service pool for the maintenance and/or the removal of the equipment either in the reactor pool or service pool. The pool door consists of stainless steel plates supported by structural steel frames and sealing components. The pool door is equipped with double inflatable gaskets. The configuration of the pool door is shown in Figure 1. The FEM analysis and theoretical calculation by the formula were performed to evaluate the natural frequency for the pool door in the water. The results from the two methods were compared.

  10. Novel Door-opening Method for Six-legged Robots Based on Only Force Sensing

    Science.gov (United States)

    Chen, Zhi-Jun; Gao, Feng; Pan, Yang

    2017-09-01

    Current door-opening methods are mainly developed on tracked, wheeled and biped robots by applying multi-DOF manipulators and vision systems. However, door-opening methods for six-legged robots are seldom studied, especially using 0-DOF tools to operate and only force sensing to detect. A novel door-opening method for six-legged robots is developed and implemented to the six-parallel-legged robot. The kinematic model of the six-parallel-legged robot is established and the model of measuring the positional relationship between the robot and the door is proposed. The measurement model is completely based on only force sensing. The real-time trajectory planning method and the control strategy are designed. The trajectory planning method allows the maximum angle between the sagittal axis of the robot body and the normal line of the door plane to be 45º. A 0-DOF tool mounted to the robot body is applied to operate. By integrating with the body, the tool has 6 DOFs and enough workspace to operate. The loose grasp achieved by the tool helps release the inner force in the tool. Experiments are carried out to validate the method. The results show that the method is effective and robust in opening doors wider than 1 m. This paper proposes a novel door-opening method for six-legged robots, which notably uses a 0-DOF tool and only force sensing to detect and open the door.

  11. Esophageal achalasia : results of balloon dilation

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Won Woo; Kang, Sung Gwon; Yoon, Kwon Ha; Kim, Nam Hyeon; Lee, Hyo Jeong; Yoon, Hyun Ki; Sung, Kyu Bo; Song, Ho Young [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-08-01

    To evaluate the clinical effectiveness of fluoroscopically guided balloon dilation in the treatment of esophageal achalasia. Under fluoroscopic guidance, 21 balloon dilation procedures were performed in 14 patients with achalasia. A balloon with a diameter of 20 mm was used for the initial attempt.If the patient tolerated this well, the procedure was repeated with a 10-20 mm balloon, placed alongside at the same session. If, however the patient complained of severe chest pain and/or a postprocedural esophagogram showed an improvement,the additional balloon was not used. For patients whose results were unsatisfactory, the dilation procedure was repeated at sessions three to seven days apart. Succesful dilation was achieved in 13 of 14 patients(92.9%), who needed a total of 20 sessions of balloon dilation, ranging from one to three sessions per patient(mean, 1.54 sessions). Esophageal rupture occured in one of 14 patients(7.1%) ; of the 13 patients who underwent a successful dilation procedure, 12(92.3%) were free of recurrent symptoms during the follow-up period of 1-56(mean, 18.5) months. The remaning patient(7.7%) had a recurrence seven months after dilation. Fluoroscopically guided balloon dilation seems to be safe and effective in the treatment of esophageal achalasia.

  12. Esophageal achalasia : results of balloon dilation

    International Nuclear Information System (INIS)

    Ki, Won Woo; Kang, Sung Gwon; Yoon, Kwon Ha; Kim, Nam Hyeon; Lee, Hyo Jeong; Yoon, Hyun Ki; Sung, Kyu Bo; Song, Ho Young

    1996-01-01

    To evaluate the clinical effectiveness of fluoroscopically guided balloon dilation in the treatment of esophageal achalasia. Under fluoroscopic guidance, 21 balloon dilation procedures were performed in 14 patients with achalasia. A balloon with a diameter of 20 mm was used for the initial attempt.If the patient tolerated this well, the procedure was repeated with a 10-20 mm balloon, placed alongside at the same session. If, however the patient complained of severe chest pain and/or a postprocedural esophagogram showed an improvement,the additional balloon was not used. For patients whose results were unsatisfactory, the dilation procedure was repeated at sessions three to seven days apart. Succesful dilation was achieved in 13 of 14 patients(92.9%), who needed a total of 20 sessions of balloon dilation, ranging from one to three sessions per patient(mean, 1.54 sessions). Esophageal rupture occured in one of 14 patients(7.1%) ; of the 13 patients who underwent a successful dilation procedure, 12(92.3%) were free of recurrent symptoms during the follow-up period of 1-56(mean, 18.5) months. The remaning patient(7.7%) had a recurrence seven months after dilation. Fluoroscopically guided balloon dilation seems to be safe and effective in the treatment of esophageal achalasia

  13. Fasting and meal-suppressed ghrelin levels before and after intragastric balloons and balloon-induced weight loss

    NARCIS (Netherlands)

    Mathus-Vliegen, E. M. H.; Eichenberger, R. I.

    2014-01-01

    Intragastric balloons may be an option for obese patients with weight loss failure. Its mode of action remains enigmatic. We hypothesised depressed fasting ghrelin concentrations and enhanced meal suppression of ghrelin secretion by the gastric fundus through balloon contact and balloon-induced

  14. Fluorescence Lyman-Alpha Stratospheric Hygrometer (FLASH): application on meteorological balloons, long duration balloons and unmanned aerial vehicles.

    Science.gov (United States)

    Lykov, Alexey; Khaykin, Sergey; Yushkov, Vladimir; Efremov, Denis; Formanyuk, Ivan; Astakhov, Valeriy

    The FLASH instrument is based on the fluorescent method, which uses H2O molecules photodissociation at a wavelength lambda=121.6 nm (Lalpha - hydrogen emission) followed by the measurement of the fluorescence of excited OH radicals. The source of Lyman-alpha radiation is a hydrogen discharge lamp while the detector of OH fluorescence at 308 -316 nm is a photomultiplier run in photon counting mode. The intensity of the fluorescent light as well as the instrument readings is directly proportional to the water vapor mixing ratio under stratospheric conditions with negligible oxygen absorption. Initially designed for rocket-borne application, FLASH has evolved into a light-weight balloon sonde (FLASH-B) for measurements in the upper troposphere and stratosphere on board meteorological and small plastic balloons. This configuration has been used in over 100 soundings at numerous tropical mid-latitude and polar locations within various international field campaigns. An airborne version of FLASH instrument is successfully utilized onboard stratospheric M55-Geophysica aircraft and tropospheric airborne laboratory YAK42-Roshydromet. The hygrometer was modified for application onboard stratospheric long-duration balloons (FLASH-LDB version). This version was successfully used onboard CNES super-pressure balloon launched from SSC Esrange in March 2007 and flown during 10 days. Special design for polar long duration balloon PoGOLite was created for testing work during polar day in June 2013. Installation and measurement peculiarities as well as observational results are presented. Observations of water vapour using FLASH-B instrument, being of high quality are rather costly as the payload recovery is often complicated and most of the time impossible. Following the goal to find a cost-efficient solution, FLASH was adapted for use onboard Unmanned Aerial Vehicles (UAV). This solution was only possible thanks to compactness and light-weight (0.5 kg) of FLASH instrument. The

  15. Endoscopic balloon dilatation of intestinal strictures in Crohn's disease: safe alternative to surgery.

    Science.gov (United States)

    Ajlouni, Yousef; Iser, John H; Gibson, Peter R

    2007-04-01

    Endoscopic balloon dilatation (EBD), a non-surgical treatment option for intestinal strictures in Crohn's disease, appears to be applied infrequently, possibly due to the perceived risk of perforation and early recurrence. This study aimed to determine the outcomes of EBD by a single endoscopist using a defined technique. The records of all patients with Crohn's disease in whom EBD was attempted over a 12-year period were examined to determine the rate of technical success, complications and outcome. A stricture was defined as that which prevented passage of the 14 mm diameter colonoscope. Technical success was defined as the ability to traverse the stricture postdilatation. Patients were selected on the colonoscopic appearance of the stricture and dilatation was performed using through-the-endoscope balloons. Antibiotics were given during and for 7 days postdilatation. EBD was attempted on 83 strictures (31 anastomotic and 52 primary) in 37 patients (15 males) and was successful in 75 (90%) of 31 patients. A single dilatation only was required in 21 patients who had a median follow-up of 20 months (range 6-122 months). Recurrent symptomatic stricture requiring dilatation (eight patients) or surgery (two patients) occurred 8 (1-112) months after the initial dilatation. The only complication occurred in one patient where an intra-abdominal fistula and abscess were probably related to the dilatation. EBD of intestinal strictures associated with Crohn's disease has a low complication rate and leads to prolonged clinical benefit. It should be considered as a real alternative to surgery.

  16. Hyperspectral Polarimeter for Monitoring Balloon Strain, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's latest generation of superpressure, ultra long duration balloons (ULDB) extend the flight time for stratospheric experiments to levels previously unattainable...

  17. Sweet Spots and Door Stops

    Science.gov (United States)

    Thompson, Michael; Tsui, Stella; Leung, Chi Fan

    2011-01-01

    A sweet spot is referred to in sport as the perfect place to strike a ball with a racquet or bat. It is the point of contact between bat and ball where maximum results can be produced with minimal effort from the hand of the player. Similar physics can be applied to the less inspiring examples of door stops; the perfect position of a door stop is…

  18. Magnesium-made door frame for passenger cars; Pkw-Tuerrahmen aus Magnesium

    Energy Technology Data Exchange (ETDEWEB)

    Tikal, F.; Vollmer, C. [Kassel Univ. (Gesamthochschule) (Germany). Inst. fuer Produktionstechnik und Logistik

    1997-11-01

    One of the most complicated parts of a car is the door. An so it will be in the future. More and more parts will be integrated in a car`s door, especially safety and comfort related parts as well as a big number of functional elements. The car industry tries intensively to bring about a growing safety image to its buyers. At the Institute for Technical Production and Logistics (IPL) of the University of Kassel (GhK) a passenger door construction out of magnesium has been developed on the base of a foregoing construction. With the new practice orientated model the time of production could be essentially reduced while at the same time the weight could be decreased. (orig.) [Deutsch] Am Institut fuer Produktionstechnik und Logistik (ipl) der Universitaet Gesamthochschule Kassel wurde ein optimierter Magnesium-Druckguss-Rahmen fuer eine Pkw-Tuer, basierend auf einer vorangegangenen Arbeit, entwickelt. Mit dem neuen praxisnahen Modell konnte die Montagezeit erheblich reduziert und Gewicht eingespart werden. (orig.)

  19. Ballooning stable high beta tokamak equilibria

    International Nuclear Information System (INIS)

    Tuda, Takashi; Azumi, Masafumi; Kurita, Gen-ichi; Takizuka, Tomonori; Takeda, Tatsuoki

    1981-04-01

    The second stable regime of ballooning modes is numerically studied by using the two-dimensional tokamak transport code with the ballooning stability code. Using the simple FCT heating scheme, we find that the plasma can locally enter this second stable regime. And we obtained equilibria with fairly high beta (β -- 23%) stable against ballooning modes in a whole plasma region, by taking into account of finite thermal diffusion due to unstable ballooning modes. These results show that a tokamak fusion reactor can operate in a high beta state, which is economically favourable. (author)

  20. NASA balloon design and flight - Philosophy and criteria

    Science.gov (United States)

    Smith, I. S., Jr.

    1993-01-01

    The NASA philosophy and criteria for the design and flight of scientific balloons are set forth and discussed. The thickness of balloon films is standardized at 20.3 microns to isolate potential film problems, and design equations are given for specific balloon parameters. Expressions are given for: flight-stress index, total required thickness, cap length, load-tape rating, and venting-duct area. The balloon design criteria were used in the design of scientific balloons under NASA auspices since 1986, and the resulting designs are shown to be 95 percent effective. These results represent a significant increase in the effectiveness of the balloons and therefore indicate that the design criteria are valuable. The criteria are applicable to four balloon volume classes in combination with seven payload ranges.

  1. Ballooning Representation Approach to Low-Frequency Instabilities in Stellarators

    International Nuclear Information System (INIS)

    Dewar, R.L.; Gardner, H.J.; Lewandowski, J.; Persson, M.

    1995-01-01

    Local ideal MHD ballooning eigenvalues have been calculated on many field lines for heliac and torsatron cases using a parallel implementation of a ballooning code on a Thinking Machines Corporation CM-5 Global eigenvalues have been estimated for the torsatron test case using the ray tracing method of Dewar and Glasser and also by using the TERPSI-CHORE global eigenvalue code, with good agreement. As a preliminary to detailed study of H-1, 3-D visualizations of stability-related quantities have been produced. 6 refs

  2. Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir

    Directory of Open Access Journals (Sweden)

    Tarcísio Passos Ribeiro de Campos

    2016-04-01

    Full Text Available Abstract Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with 99mTc and balloon brachytherapy with high-dose-rate (HDR 192Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and Methods: Simulations of implants with 99mTc-filled and HDR 192Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: The 99mTc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h-1.mCi-1 and 0.190 cGyh-1.mCi-1 at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh-1.mCi-1, respectively, for the HDR 192Ir balloon. An exposure time of 24 hours was required for the 99mTc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR 192Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: Temporary 99mTc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR 192Ir balloon implantation, which is the current standard in clinical practice.

  3. Bulkhead Door – Critical Evacuation States

    Directory of Open Access Journals (Sweden)

    Flizikowski Józef

    2017-03-01

    Full Text Available The article is a preliminary to a modification concept of the sliding watertight bulkhead door used on ships and vessels. Hydraulic or electro-hydraulic drives used to move these doors require complicated and extended pressure installations with large amounts of hydraulic fluid. Well-known operational drawbacks of these installations include high level of noise and possibility of various leaks in the hydraulic system. Being the first in a series, the present article describes and analyses critical states which can take place during evacuation of people through openings in the watertight bulkhead doors on seagoing ships and vessels.

  4. Effect of intra-aortic balloon pump on coronary blood flow during different balloon cycles support: A computer study.

    Science.gov (United States)

    Aye, Thin Pa Pa; Htet, Zwe Lin; Singhavilai, Thamvarit; Naiyanetr, Phornphop

    2015-01-01

    Intra-aortic balloon pump (IABP) has been used in clinical treatment as a mechanical circulatory support device for patients with heart failure. A computer model is used to study the effect on coronary blood flow (CBF) with different balloon cycles under both normal and pathological conditions. The model of cardiovascular and IABP is developed by using MATLAB SIMULINK. The effect on coronary blood flow has been studied under both normal and pathological conditions using different balloon cycles (balloon off; 1:4; 1:2; 1:1). A pathological heart is implemented by reducing the left ventricular contractility. The result of this study shows that the rate of balloon cycles is related to the level of coronary blood flow.

  5. Early Cosmic Ray Research with Balloons

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Michael, E-mail: michael.walter@desy.de

    2013-06-15

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  6. Early Cosmic Ray Research with Balloons

    Science.gov (United States)

    Walter, Michael

    2013-06-01

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  7. Early Cosmic Ray Research with Balloons

    International Nuclear Information System (INIS)

    Walter, Michael

    2013-01-01

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster

  8. Are drug-coated balloons cost effective for femoropopliteal occlusive disease? A comparison of bare metal stents and uncoated balloons.

    Science.gov (United States)

    Poder, Thomas G; Fisette, Jean-François

    2016-07-01

    To perform a cost-effectiveness analysis to help hospital decision-makers with regard to the use of drug-coated balloons compared with bare metal stents and uncoated balloons for femoropopliteal occlusive disease. Clinical outcomes were extracted from the results of meta-analyses already published, and cost units are those used in the Quebec healthcare network. The literature review was limited to the last four years to obtain the most recent data. The cost-effectiveness analysis was based on a 2-year perspective, and risk factors of reintervention were considered. The cost-effectiveness analysis indicated that drug-coated balloons were generally more efficient than bare metal stents, particularly for patients with higher risk of reintervention (up to CAD$1686 per patient TASC II C or D). Compared with uncoated balloons, results indicated that drug-coated balloons were more efficient if the reintervention rate associated with uncoated balloons is very high and for patients with higher risk of reintervention (up to CAD$3301 per patient). The higher a patient's risk of reintervention, the higher the savings associated with the use of a drug-coated balloon will be. For patients at lower risk, the uncoated balloon strategy is still recommended as a first choice for endovascular intervention.

  9. Anderson localization and ballooning eigenfunctions

    International Nuclear Information System (INIS)

    Dewar, R.L.; Cuthbert, P.

    1999-01-01

    In solving the ballooning eigenvalue for a low-aspect-ratio stellarator equilibrium it is found that the quasiperiodic behaviour of the equilibrium quantities along a typical magnetic field line can lead to localization of the ballooning eigenfunction (Anderson localization) even in the limit of zero shear. This localization leads to strong field-line dependence of the ballooning eigenvalue, with different branches attaining their maximum growth rates on different field lines. A method is presented of estimating the field-line dependence of various eigenvalue branches by using toroidal and poloidal symmetry operations on the shear-free ballooning equation to generate an approximate set of eigenfunctions. These zero-shear predictions are compared with accurate numerical solutions for the H-1 Heliac and are shown to give a qualitatively correct picture, but finite shear corrections will be needed to give quantitative predictions

  10. Catching Comet's Particles in the Earth's Atmosphere by Using Balloons

    Science.gov (United States)

    Potashko, Oleksandr; Viso, Michel

    Indian Space Research Organization experience that launched a balloon to stratosphere in 2009 and successfully caught particles with organics at an altitude of 42 km. The main aim of the project is to catch cometary particles by using balloons and to make this method steady and reliable. Why are the comet particles interesting? The nature of a comet is full of puzzles; many researchers think that comets may give keys to the origin of the Solar System and origin of life on the Earth. 2014 and 2015 are special years for comet science: mission Rozetta will reach the vicinity of the comet 67P/Churyumov-Gerasimenko - 10 years after leaving the Earth. Using astronomic data, one may choose date for ballooning, specify the altitude of comet particles by photometry and laser measurement of particle outburst. After height measurement one may launch a balloon. For example, for Draconids particles (Parent comet: 21PGiacobini-Zinner) the expected time of outburst maximum - hence that for catching is 22:42 UT, October 6, 2014. The best conditions for catching will be in Greenland and extreme north-eastern part of North America. Draconids are very convenient for the initial stage of the project - the altitude of observed Draconids outburst is 10 km. One may catch them above 10 km, e.g. 10500 m. We consider ballooning is quite a good method to get experimental data as an additional technique in comparison with big space missions. Moreover, it might be a part of cosmic mission to other planets such as Mars and Venus. The approach of the project is to make targeting catch of comet particles. The method consists of choosing the right place and time for ballooning.

  11. Traumatic asphyxia--fatal accident in an automatic revolving door.

    Science.gov (United States)

    Cortis, J; Falk, J; Rothschild, M A

    2015-09-01

    Due to continuing modernisation, the number of automatic doors in routine use, including powered revolving doors, has increased in recent years. Automatic revolving doors are found mostly in department stores, airports, railway stations and hospitals. Although safety arrangements and guidelines concerning the installation of automatic doors are in existence, their disregard in conjunction with obsolete or incorrect installation can lead to fatal accidents. In this report, a 19-month-old boy is described whose right arm was caught between the elements of an automatic revolving door. As a direct result of rescue attempts, the child's body was drawn further into the narrow gap between elements of the door. To get the boy's body out of the 4-cm-wide gap between the fixed outer wall of the revolving door and the revolving inner, back-up batteries had to be disconnected so as to stop the electrical motor powering the door. Cardiopulmonary resuscitation was begun immediately after the rescue but was unsuccessful; the child was declared dead at the hospital he was taken to. The cause of death was a combination of compression-related skull and brain injury together with thoracic compression. This case shows an outstanding example of the preventive aspect as a special task of forensic medicine. Additionally, it serves as a warning for the correct installation and use of automatic revolving doors. Even so, small children should not use these doors on their own, but only with an alert companion, so as to prevent further fatal accidents of this sort.

  12. The German scientific balloon and sounding rocket programme

    International Nuclear Information System (INIS)

    Dahl, A.F.

    1980-01-01

    This report contains information on sounding rocket projects in the scientific field of astronomy, aeronomy, magnetosphere, and material science under microgravity. The scientific balloon projects are performed with emphasis on astronomical research. By means of tables it is attempted to give a survey, as complete as possible, of the projects the time since the last symposium in Ajaccio, Corsica, and of preparations and plans for the future until 1983. The scientific balloon and sounding rocket projects form a small successful part of the German space research programme. (Auth.)

  13. Doors for memory: A searchable database.

    Science.gov (United States)

    Baddeley, Alan D; Hitch, Graham J; Quinlan, Philip T; Bowes, Lindsey; Stone, Rob

    2016-11-01

    The study of human long-term memory has for over 50 years been dominated by research on words. This is partly due to lack of suitable nonverbal materials. Experience in developing a clinical test suggested that door scenes can provide an ecologically relevant and sensitive alternative to the faces and geometrical figures traditionally used to study visual memory. In pursuing this line of research, we have accumulated over 2000 door scenes providing a database that is categorized on a range of variables including building type, colour, age, condition, glazing, and a range of other physical characteristics. We describe an illustrative study of recognition memory for 100 doors tested by yes/no, two-alternative, or four-alternative forced-choice paradigms. These stimuli, together with the full categorized database, are available through a dedicated website. We suggest that door scenes provide an ecologically relevant and participant-friendly source of material for studying the comparatively neglected field of visual long-term memory.

  14. 27. The impact of introduction of code-stemi program on clinical outcomes of acute st-elevation myocardial infarction (stemi patients undergoing primary pci: Single center study in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    A. ALYAHYA

    2016-07-01

    Full Text Available This study was conducted to evaluate the effect of direct Emergency Department activation of the Catheterization Lab on door to balloon (D2B time and outcomes of acute ST-elevation myocardial infarction (STEMI patients in King Khalid University Hospital (KKUH. Establishing dedicated comprehensive STEMI programs aiming at reducing door to balloon time will impact favourably the outcomes of patients presenting with acute STEMI. This was a retrospective cohort study that involved 100 patients in KKUH who presented with acute STEMI and underwent primary percutaneous intervention (PPCI, between June 2010 and January 2015. The cohort was divided into two groups, the first group consisted of 50 patients who were treated before establishing the Code-STEMI protocol, whereas the second group were 50 patients who were treated according to the protocol, which was implemented in June 2013. Code-STEMI program is a comprehensive program that includes direct activation of the cath lab team using a single call system, data monitoring and feedback, and standardized order forms. The mean age in both groups was 54 ± 12 years and 86% (43 and 94% (47 of the patients in the two groups were males, respectively. 90% (90 of patients in both groups had one or more comorbidities.Code-STEMI group had a significantly lower D2BT with 70% of patients treated within the recommended 90 minutes (median = 76.5 min, IQR: 63–90 min compared to only 26% of pre code-STEMI patients (median = 107 min, IQR: 74–149 min In-hospital complications were lower in the Code-STEMI group; however, the only statistically significant reduction was in non-fatal re-infarction, (8% vs. 0%, p = 0.043. In addition, the number of patients with more than one in-hospital complications was also reduced by 20%.Implementation of direct ER-Catheterization lab activation protocol was associated with a significant reduction in D2B time, and an overall improvement of in-hospital outcomes.

  15. SAFETY BULLETIN TIS 2002-03 GLASS DOORS

    CERN Multimedia

    2002-01-01

    Be careful! What happened?   Unsignaled reinforced glass.   Signaled safety glass.   A visitor recently hurt his leg when he walked into a glass door which shattered from the impact. This door was made of reinforced glass, a material which is inappropriate for this kind of use as it is too fragile. Indeed, it shatters into sharp splinters which can cause serious injury. Furthermore, the door was not easily visible (badly lit, no warning signs, ...). Corrective measures Just after the accident: glass doors were signed to make them more visible; replacement of dangerous glass panes planned for 2003. What preventive measures can be taken against this kind of accident? If you are in charge of projects and works: In the call for tender, specify the acceptable shock resistance level of the glass pane; Before the door is mounted, insist on receiving technical documentation and/or certificate of conformity from the supplier; If in doubt, ask advice from the TIS/GS sa...

  16. Motor actuated vacuum door. [for photography from sounding rockets

    Science.gov (United States)

    Hanagud, A. V.

    1986-01-01

    Doors that allow scientific instruments to record and retrieve the observed data are often required to be designed and installed as a part of sounding rocket hardware. The motor-actuated vacuum door was designed to maintain a medium vacuum of the order of 0.0001 torr or better while closed, and to provide an opening 15 inches long x 8.5 inches wide while open for cameras to image Halley's comet. When the electric motor receives the instruction to open the door through the payload battery, timer, and relay circuit, the first operation is to unlock the door. After unlatching, the torque transmitted by the motor to the main shaft through the links opens the door. A microswitch actuator, which rides on the linear motion conversion mechanism, is adjusted to trip the limit switch at the end of the travel. The process is repeated in the reverse order to close the door. 'O' rings are designed to maintain the seal. Door mechanisms similar to the one described have flown on Aerobee 17.018 and Black Brant 27.047 payloads.

  17. Gas dynamic laser having shutter doors

    International Nuclear Information System (INIS)

    Olinger, J.B. Jr.; Wahl, R.L.

    1975-01-01

    A gas dynamic laser is shown wherein gases containing constituents necessary to obtain a lasing action are passed through a nozzle array and directed into a lasing cavity and through a diffuser to an exit. An opening is located on each side of said lasing cavity with a shutter box outside of said cavity having a shutter door for opening or closing said opening. A mirror box is located behind each shutter box and contains a mirror. These mirrors are aligned with the openings in the lasing cavity with each door positioned between an opening and a mirror. Another outlet opening is positioned downstream of the first opening which provides an outlet opening for a laser beam. A shutter box is located around this opening and also houses a shutter door for opening and closing said opening. The mirror box which extends behind this shutter box includes opening means for permitting the output beam to pass through an aerodynamic window to atmosphere. Actuating means are provided for rapidly opening and closing said shutter doors. Bearing means including recirculating balls are located on the top and bottom of each shutter door to ride in tracks at an angle to the sealing surface on the laser device. Vacuum means are provided to reduce the pressure in the shutter box and mirror box independently of the pressure in the lasing cavity

  18. 29 CFR 1917.114 - Cargo doors.

    Science.gov (United States)

    2010-07-01

    ... counterweights shall be guarded. (2) Lift trucks and cranes shall not be used to move mechanically operated doors.... (1) The door shall be connected to its lifting tackle with shackles or equally secure means. (2) Lifting bridles and tackles shall have a safety factor of five, based upon maximum anticipated static...

  19. The French balloon and sounding rocket space program

    Science.gov (United States)

    Coutin/Faye, S.; Sadourny, I.

    1987-08-01

    Stratospheric and long duration flight balloon programs are outlined. Open stratospheric balloons up to 1 million cu m volume are used to carry astronomy, solar system, aeronomy, stratosphere, biology, space physics, and geophysics experiments. The long duration balloons can carry 50 kg payloads at 20 to 30 km altitude for 10 days to several weeks. Pressurized stratospheric balloons, and infrared hot air balloons are used. They are used to study the dynamics of stratospheric waves and atmospheric water vapor. Laboratories participating in sounding rocket programs are listed.

  20. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won [Konyang University Hospital, Daejeon (Korea, Republic of)

    2005-12-15

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful.

  1. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    International Nuclear Information System (INIS)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won

    2005-01-01

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful

  2. Development of a tornado safe room door from wood Products: door design and impact testing

    Science.gov (United States)

    Robert H. Falk; James J. Bridwell

    2016-01-01

    In this study, a tornado safe room door built from wood products and steel sheeting was developed and impact-tested according to tornado safe room standards. Results indicate that an door constructed from as few as two sheets of 23/32-in. (18.26-mm) construction-grade plywood and overlaid with 18-gauge (0.05-in.- (1.27- mm-) thick) steel can pass the required impact...

  3. Balloon-borne stratospheric BrO measurements: comparison with Envisat/SCIAMACHY BrO limb profiles

    Directory of Open Access Journals (Sweden)

    M. Dorf

    2006-01-01

    Full Text Available For the first time, results of four stratospheric BrO profiling instruments, are presented and compared with reference to the SLIMCAT 3-dimensional chemical transport model (3-D CTM. Model calculations are used to infer a BrO profile validation set, measured by 3 different balloon sensors, for the new Envisat/SCIAMACHY (ENVIronment SATellite/SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY satellite instrument. The balloon observations include (a balloon-borne in situ resonance fluorescence detection of BrO (Triple, (b balloon-borne solar occultation DOAS measurements (Differential Optical Absorption Spectroscopy of BrO in the UV, and (c BrO profiling from the solar occultation SAOZ (Systeme d'Analyse par Observation Zenithale balloon instrument. Since stratospheric BrO is subject to considerable diurnal variation and none of the measurements are performed close enough in time and space for a direct comparison, all balloon observations are considered with reference to outputs from the 3-D CTM. The referencing is performed by forward and backward air mass trajectory calculations to match the balloon with the satellite observations. The diurnal variation of BrO is considered by 1-D photochemical model calculation along the trajectories. The 1-D photochemical model is initialised with output data of the 3-D model with additional constraints on the vertical transport, the total amount and photochemistry of stratospheric bromine as given by the various balloon observations. Total [Bry]=(20.1±2.5 pptv obtained from DOAS BrO observations at mid-latitudes in 2003, serves as an upper limit of the comparison. Most of the balloon observations agree with the photochemical model predictions within their given error estimates. First retrieval exercises of BrO limb profiling from the SCIAMACHY satellite instrument on average agree to around 20% with the photochemically-corrected balloon observations of the remote sensing instruments (SAOZ

  4. TMBM: Tethered Micro-Balloons on Mars

    Science.gov (United States)

    Sims, M. H.; Greeley, R.; Cutts, J. A.; Yavrouian, A. H.; Murbach, M.

    2000-01-01

    The use of balloons/aerobots on Mars has been under consideration for many years. Concepts include deployment during entry into the atmosphere from a carrier spacecraft, deployment from a lander, use of super-pressurized systems for long duration flights, 'hot-air' systems, etc. Principal advantages include the ability to obtain high-resolution data of the surface because balloons provide a low-altitude platform which moves relatively slowly. Work conducted within the last few years has removed many of the technical difficulties encountered in deployment and operation of balloons/aerobots on Mars. The concept proposed here (a tethered balloon released from a lander) uses a relatively simple approach which would enable aspects of Martian balloons to be tested while providing useful and potentially unique science results. Tethered Micro-Balloons on Mars (TMBM) would be carried to Mars on board a future lander as a stand-alone experiment having a total mass of one to two kilograms. It would consist of a helium balloon of up to 50 cubic meters that is inflated after landing and initially tethered to the lander. Its primary instrumentation would be a camera that would be carried to an altitude of up to tens of meters above the surface. Imaging data would be transmitted to the lander for inclusion in the mission data stream. The tether would be released in stages allowing different resolutions and coverage. In addition during this staged release a lander camera system may observe the motion of the balloon at various heights above he lander. Under some scenarios upon completion of the primary phase of TMBM operations, the tether would be cut, allowing TMBM to drift away from the landing site, during which images would be taken along the ground.

  5. Real-time profiling of organic trace gases in the planetary boundary layer by PTR-MS using a tethered balloon

    Directory of Open Access Journals (Sweden)

    R. Schnitzhofer

    2009-12-01

    Full Text Available A method for real-time profiling of volatile organic compounds (VOCs was developed combining the advantages of a tethered balloon as a research platform and of proton transfer reaction mass spectrometry (PTR-MS as an analytical technique for fast and highly sensitive VOC measurements. A 200 m Teflon tube was used to draw sampling air from a tethered aerodynamic balloon to the PTR-MS instrument. Positive and negative artefacts (i.e. formation and loss of VOCs in the tube were characterised in the laboratory and in the field by a set of 11 atmospherically relevant VOCs including both pure and oxygenated hydrocarbons. The only two compounds that increased or decreased when sampled through the tube were acetone (+7% and xylene (-6%. The method was successfully deployed during a winter field campaign to determine the small scale spatial and temporal patterns of air pollutants under winter inversion conditions.

  6. Doors and thresholds: Jeddi's approach to psychiatric disorders.

    Science.gov (United States)

    Devisch, R; Vervaeck, B

    1986-01-01

    Professor Essedik Jeddi and his team have introduced a most significant institutional and therapeutic innovation at the Ibn Rochd and Pinel section of the Razi university long-term mental hospital in Tunis (Tunisia). The innovation focuses upon the ambiguity of doors and boundaries in the mental asylum. Doors and walls influence the rhythm of activity and the nature of contact between patients, therapists and the wider society and culture. If they are very rigid, they may disjoin the patient from him- or herself, from his/her body, social network and culture. On the other hand, if such boundaries are completely neglected they may merge these related dimensions as undifferentiated entities. Jeddi's innovation is primarily concerned with placing the spatio-temporal experience of the body and the intimate interpersonal interaction at the centre of treatment. It aims at establishing creative modes of expression, interaction and exchange such as tea-sessions, dancing, singing, verbal communication, clay-modelling, figurative or plastic expression, agricultural works. These relationships mediate and differentiate at the same time between the patient, his/her body-self, and his/her social and cultural world, thus avoiding both the disjunction and the merging. It would seem that the activities concerned with the distinction between 'inside' and 'outside', peasant and urban, self and other (e.g. dancing and singing) are of paramount importance in bringing about such mediating and differentiating relationships. In the present study we limit ourselves to one particularly revealing therapeutic activity, namely dancing to live music. Jeddi's innovation is a unique blend of current developments in psychiatry and psychotherapy with Arabo-Islamic science and philosophy.

  7. Barriers to and enablers for European rail freight transport for integrated door-to-door logistics service. Part 1: Barriers to multimodal rail freight transport

    Directory of Open Access Journals (Sweden)

    Dewan Md Zahurul ISLAM

    2014-09-01

    Full Text Available The objective of this paper is to examine and identify barriers to and enablers for the European rail freight transport services as a transport chain partner along the supply chains in the changing market scenario. The changing market scenario includes, among others, requiring 'door-to-door' rather than 'terminal to terminal' and integrated service, competitive ability to attract non-rail cargo type, changes in the customer requirements (e.g. reliable service and changes in the operational requirements and practices. Using a literature review method, the paper is presented in two parts. The part 1 focuses on the identification of barriers to the European rail freight service by reviewing freight logistics services for global supply chains followed by the current performance of European rail freight transport followed by a discussion on the rail freight market liberalisation in Europe. Then rail freight transport in the Unites States (U.S. is discussed. The research notes that although the background, scope and necessity for reform measures in Europe differ from those of the U.S., some lessons can be learned and the main lesson is that an appropriate reform measure can enhance rail sector competitive ability in Europe. Examining and identifying the barriers in the part 1 (with the pan-Pacific examples of rail freight transports, the part 2 of the paper focuses on recommending clear actions and steps as enablers for the rail freight industry in general and operators in particular. The research in part 1 of the paper finds that: •\tIn many European countries, the rail freight market is not fully liberalised. In such market segment, infrastructure managers do act independently for incumbents and new entrant operators that hamper the progress of building a competitive market; •\tThe rail operators have not yet achieved the service quality (e.g. customer tailored service needed for the modern supply chains; •\tThey operate ‘terminal-to

  8. Design Report for ACP Hot Cell Rear Door

    Energy Technology Data Exchange (ETDEWEB)

    Ku, J. H.; Kwon, K. C.; Choung, W. M.; Cho, I. J.; Kook, D. H.; Lee, W. K.; You, G. S.; Lee, E. P.; Park, S. W

    2005-12-15

    A hot-cell facility was constructed at the IMEF building for the demonstrate ACP process. ACP hot-cell consists of process cell and maintenance cell, and each cell has rear door. Since this facility was constructed at basement floor, all process materials, equipment and radioactive materials are take in and out through the rear door. Also, this door can be an access route of workers for the maintenance works. Therefore ACP hot-cell rear doors must maintain the radiation shielding, sealing, mechanical and structural safety. This report presents design criteria, design contents of each part and driving part. It was confirmed that the rear doors sufficiently maintain the safety through the structural analysis and shielding analysis. Also, it was confirmed that the rear doors were constructed as designed by the gamma scanning test after the installation.

  9. Design Report for ACP Hot Cell Rear Door

    International Nuclear Information System (INIS)

    Ku, J. H.; Kwon, K. C.; Choung, W. M.; Cho, I. J.; Kook, D. H.; Lee, W. K.; You, G. S.; Lee, E. P.; Park, S. W.

    2005-12-01

    A hot-cell facility was constructed at the IMEF building for the demonstrate ACP process. ACP hot-cell consists of process cell and maintenance cell, and each cell has rear door. Since this facility was constructed at basement floor, all process materials, equipment and radioactive materials are take in and out through the rear door. Also, this door can be an access route of workers for the maintenance works. Therefore ACP hot-cell rear doors must maintain the radiation shielding, sealing, mechanical and structural safety. This report presents design criteria, design contents of each part and driving part. It was confirmed that the rear doors sufficiently maintain the safety through the structural analysis and shielding analysis. Also, it was confirmed that the rear doors were constructed as designed by the gamma scanning test after the installation

  10. Pre-hospital electrocardiogram triage with tele-cardiology support is associated with shorter time-to-balloon and higher rates of timely reperfusion even in rural areas: data from the Bari- Barletta/Andria/Trani public emergency medical service 118 registry on primary angioplasty in ST-elevation myocardial infarction.

    Science.gov (United States)

    Brunetti, Natale Daniele; Di Pietro, Gaetano; Aquilino, Ambrogio; Bruno, Angela I; Dellegrottaglie, Giulia; Di Giuseppe, Giuseppe; Lopriore, Claudio; De Gennaro, Luisa; Lanzone, Saverio; Caldarola, Pasquale; Antonelli, Gianfranco; Di Biase, Matteo

    2014-09-01

    We report the preliminary data from a regional registry on ST-elevation myocardial infarction (STEMI) patients treated with primary angioplasty in Apulia, Italy; the region is covered by a single public health-care service, a single public emergency medical service (EMS), and a single tele-medicine service provider. Two hundred and ninety-seven consecutive patients with STEMI transferred by regional free public EMS 1-1-8 for primary-PCI were enrolled in the study; 123 underwent pre-hospital electrocardiograms (ECGs) triage by tele-cardiology support and directly referred for primary-PCI, those remaining were just transferred by 1-1-8 ambulances for primary percutaneous coronary intervention (PCI) (diagnosis not based on tele-medicine ECG; already hospitalised patients, emergency-room without tele-medicine support). Time from first ECG diagnostic for STEMI to balloon was recorded; a time-to-balloon primary-PCI). Pre-hospital triage with tele-cardiology ECG in an EMS registry from an area with more than one and a half million inhabitants was associated with shorter time-to-balloon and higher rates of timely treated patients, even in 'rural' areas. © The European Society of Cardiology 2014.

  11. PERCUTANEOUS BALLOON COMPRESSION OF GASSERIAN GANGLION FOR THE TREATMENT OF TRIGEMINAL NEURALGIA: AN EXPERIENCE FROM INDIA.

    Science.gov (United States)

    Agarwal, Anurag; Dhama, Vipin; Manik, Yogesh K; Upadhyaya, M K; Singh, C S; Rastogi, V

    2015-02-01

    Trigeminal neuralgia (TN) is characterized by unilateral, lancinating, paroxysmal pain in the dermatomal distribution area of trigeminal nerve. Percutaneous balloon compression (PBC) of Gasserian ganglion is an effective, comparatively cheaper and simple therapeutic modality for treatment of TN. Compression secondary to PBC selectively injures the large myelinated A-alfa (afferent) fibers that mediate light touch and does not affect A-delta and C-fibres, which carry pain sensation. Balloon compression reduces the sensory neuronal input, thus turning off the trigger to the neuropathic trigeminal pain. In this current case series, we are sharing our experience with PBC of Gasserian Ganglion for the treatment of idiopathic TN in our patients at an academic university-based medical institution in India. During the period of August 2012 to October 2013, a total of twelve PBCs of Gasserian Ganglion were performed in eleven patients suffering from idiopathic TN. There were nine female patients and two male patients with the age range of 35-70 years (median age: 54 years). In all patients cannulation of foramen ovale was done successfully in the first attempt. In eight out of eleven (72.7%) patients ideal 'Pear-shaped' balloon visualization could be achieved. In the remaining three patients (27.3%), inflated balloon was 'Bullet-shaped'. In one patient final placement of Fogarty balloon was not satisfactory and it ruptured during inflation. This case was deferred for one week when it was completed successfully with 'Pear-shaped' balloon inflation. During the follow up period of 1-13 months, there have been no recurrences of TN. Eight out of eleven patients (72.7%) are completely off medicines (carbamazepine and baclofen) and other two patients are stable on very low doses of carbamazepine. All patients have reported marked improvement in quality of life. This case series shows that percutaneous balloon compression is a useful minimally invasive intervention for the

  12. Critical element development of double seal door for tritium containment

    International Nuclear Information System (INIS)

    Kanamori, Naokazu; Kakudate, Satoshi; Oka, Kiyoshi; Nakahira, Masataka; Taguchi, Kou; Obara, Kenjiro; Tada, Eisuke; Shibanuma, Kiyoshi; Seki, Masahiro

    1994-08-01

    In fusion experimental reactors, the in-vessel components such as blanket are activated due to D-T operation and they have to be assembled and replaced by remote operation through port penetration of plasma vacuum vessel. A double seal door is inevitably required at an interface between vacuum vessel port and maintenance cask in order to avoid the dispersion of tritium and activated dust during in-vessel component handling. The double seal door should have two open/close doors with four seal surfaces so as to keep leak tightness both of the vacuum vessel and the maintenance cask when doors closed, and to provide access space for handling in-vessel components when doors opened. A prototype compact double seal door with an attractive kinematics of parabolic trajectory has been proposed so as to minimize dead space for the door open/close operation, compared with ordinary slide or hinge type door. Based on this design concept, a sub-scaled model of double seal door with trapezoidal cross-section of around 0.2 m 2 has been fabricated. Through the preliminary experiments such as open/close performance, the double seal door mechanism with parabolic trajectory has been successfully demonstrated. As for leak tightness, seal characteristics of a polyimide ring irradiated up to 10 MGy have been measured. (author)

  13. Recent activities on the scientific ballooning in Japan

    International Nuclear Information System (INIS)

    Nisimura, J.; Hirosawa, H.

    1984-01-01

    Scientific ballooning is Japan has been organized by the Institute of Space and Astronautical Science, and about 15 balloons have been launched each year from Sanriku Balloon Center that belongs to this Institute. The balloon center is located in the northern part of Japan. The observations cover the field of X-ray, gamma-ray, infrared astronomy, cosmic rays, and atmospheric science. Systems of lon duration flights such as 'Boomerang Balloons', and fine attitude control systems were developed and widely applied to the scientific observations. International collaborative works were performed in Australia and Indonesia last year. Some details of these activities are reported and possible future collaborations with Braziian balloon group are also discussed. (Author) [pt

  14. Design proposal for door thresholds

    Directory of Open Access Journals (Sweden)

    Smolka Radim

    2017-01-01

    Full Text Available Panels for openings in structures have always been an essential and integral part of buildings. Their importance in terms of a building´s functionality was not recognised. However, the general view on this issue has changed from focusing on big planar segments and critical details to sub-elements of these structures. This does not only focus on the forms of connecting joints but also on the supporting systems that keep the panels in the right position and ensure they function properly. One of the most strained segments is the threshold structure, especially the entrance door threshold structure. It is the part where substantial defects in construction occur in terms of waterproofing, as well as in the static, thermal and technical functions thereof. In conventional buildings, this problem is solved by pulling the floor structure under the entrance door structure and subsequently covering it with waterproofing material. This system cannot work effectively over the long term so local defects occur. A proposal is put forward to solve this problem by installing a sub-threshold door coupler made of composite materials. The coupler is designed so that its variability complies with the required parameters for most door structures on the European market.

  15. Blower-door techniques for measuring interzonal leakage

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L.; Sherman, Max H.; Walker, Iain

    2013-01-01

    Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

  16. Investigation into the acceptability of door locking to staff, patients, and visitors on acute psychiatric wards.

    Science.gov (United States)

    Muir-Cochrane, Eimear; van der Merwe, Marie; Nijman, Henk; Haglund, Kristina; Simpson, Alan; Bowers, Len

    2012-02-01

    There is disagreement among psychiatric professionals about whether the doors of acute psychiatric wards should be kept locked to prevent patients from leaving and harming themselves or others. This study explored patient, staff, and visitor perceptions about the acceptability of locking the ward door on acute psychiatric inpatient wards. Interviews were conducted with 14 registered nurses, 15 patients, and six visitors from three different acute wards. Findings revealed commonalities across all groups, with general agreement that locking the door reduced absconding. Staff expressed feelings of guilt, embarrassment, and fear of being blamed when a patient absconded. Staff also reported that open wards created anxious vigilance to prevent an abscond and increased workload in allocating staff to watch the door, whereas staff on partially-locked doors also perceived an increased workload in letting people in and out of the ward. Patients had mixed feelings about the status of the door, expressing depression, a sense of stigma, and low self-esteem when the door was locked. The issue of balancing safety and security on acute psychiatric wards against the autonomy of patients is not easily resolved, and requires focused research to develop innovative nursing practices. © 2011 The Authors. International Journal of Mental Health Nursing © 2011 Australian College of Mental Health Nurses Inc.

  17. Transthoracic ultrasound guided balloon dilation of cor triatriatum dexter in 2 Rottweiler puppies.

    Science.gov (United States)

    Birettoni, F; Caivano, D; Bufalari, A; Giorgi, M E; Miglio, A; Paradies, P; Porciello, F

    2016-12-01

    Balloon dilation was performed in two Rottweiler puppies with cor triatriatum dexter and clinical signs of ascites using transthoracic echocardiographic guidance. The dogs were positioned on a standard echocardiography table in right lateral recumbency, and guide wires and balloon catheters were imaged by echocardiographic views optimized to allow visualization of the defect. The procedures were performed successfully without complications and clinical signs were resolved completely in both cases. Guide wires and balloon catheters appeared hyperechoic on transthoracic echocardiography image and could be clearly monitored and guided in real-time. These two cases demonstrate that it is possible to perform balloon catheter dilation of cor triatriatum dexter under transthoracic guidance alone. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Application of Electrocautery Needle Knife Combined with Balloon Dilatation versus Balloon Dilatation in the Treatment of Tracheal Fibrotic Scar Stenosis.

    Science.gov (United States)

    Bo, Liyan; Li, Congcong; Chen, Min; Mu, Deguang; Jin, Faguang

    Electrocautery needle knives can largely reduce scar and granulation tissue hyperplasia and play an important role in treating patients with benign stricture. The aim of this retrospective study was to evaluate the efficacy and safety of electrocautery needle knife combined with balloon dilatation versus balloon dilatation alone in the treatment of tracheal stenosis caused by tracheal intubation or tracheotomy. We retrospectively analysed the clinical data of 43 patients with tracheal stenosis caused by tracheotomy or tracheal intubation in our department from January 2013 to January 2016. Among these 43 patients, 23 had simple web-like stenosis and 20 had complex steno sis. All patients were treated under general anaesthesia, and the treatment methods were (1) balloon dilatation alone, (2) needle knife excision of fibrotic tissue combined with balloon dilatation, and (3) needle knife radial incision of fibrotic tissue combined with balloon dilatation. After treatment the symptoms, such as shortness of breath, were markedly improved immediately in all cases. The stenosis degree of patients who were treated with the elec-trocautery needle knife combined with balloon dilatation had better improvement compared with that of those treated with balloon dilatation treatment alone after 3 months (0.45 ± 0.04 vs. 0.67 ± 0.05, p knife combined with balloon dilatation is an effective and safe treatment for tracheal fibrotic stenosis compared with balloon dilatation alone. © 2017 S. Karger AG, Basel.

  19. Scientific ballooning. Proceedings of the symposium on the scientific use of balloons and related technical problems, Innsbruck, Austria, May 29-June 10, 1978

    Energy Technology Data Exchange (ETDEWEB)

    Riedler, W

    1979-01-01

    The book includes works on operational and technical aspects of balloon launching I and II, cooperative balloon campaigns, and new developments in scientific use of balloons. The specific topics discussed are coordinated balloon and rocket measurements of stratospheric wind shears and turbulence, ballooning in Japan and India, magnetospheric processes investigated with data taken from balloon flights, and remote sensing of middle atmosphere winds from balloon platforms.

  20. Long-Term Follow-up After Embolization of Pulmonary Arteriovenous Malformations with Detachable Silicone Balloons

    International Nuclear Information System (INIS)

    Andersen, Poul Erik; Kjeldsen, Anette D.

    2008-01-01

    Long-term follow-up results after embolization of 13 pulmonary arteriovenous malformations in 10 patients by use of 14 detachable silicone balloons are given. Patients were followed for a mean of 99 months (range, 63-123 months) with chest x-rays and for a mean of 62 months (range, 3-101 months) with pulmonary angiography. Fifty-four percent of the balloons were deflated at latest radiographic chest film follow-up, but at pulmonary angiographic follow-up all embolized malformations were without flow irrespective of whether or not the balloons were visible. Detachable silicone balloons are not available anymore, but use of these balloons for embolization of pulmonary arteriovenous malformations has been shown to be a safe and precise method, with immediate occlusion of the feeding artery and with long-lasting occlusion, even though many balloons deflate with time, leaving a fibrotic scar replacing the pulmonary arteriovenous malformation. No case of recanalization has been discovered, and these results seem to justify a reduced number of controls of these balloon-embolized malformations

  1. Heat Transfer Model for Hot Air Balloons

    Science.gov (United States)

    Llado-Gambin, Adriana

    A heat transfer model and analysis for hot air balloons is presented in this work, backed with a flow simulation using SolidWorks. The objective is to understand the major heat losses in the balloon and to identify the parameters that affect most its flight performance. Results show that more than 70% of the heat losses are due to the emitted radiation from the balloon envelope and that convection losses represent around 20% of the total. A simulated heating source is also included in the modeling based on typical thermal input from a balloon propane burner. The burner duty cycle to keep a constant altitude can vary from 10% to 28% depending on the atmospheric conditions, and the ambient temperature is the parameter that most affects the total thermal input needed. The simulation and analysis also predict that the gas temperature inside the balloon decreases at a rate of -0.25 K/s when there is no burner activity, and it increases at a rate of +1 K/s when the balloon pilot operates the burner. The results were compared to actual flight data and they show very good agreement indicating that the major physical processes responsible for balloon performance aloft are accurately captured in the simulation.

  2. The German scientific balloon and sounding rocket projects

    International Nuclear Information System (INIS)

    Dalh, A.F.

    1978-01-01

    This report contains information on the sounding rocket projects: experiment preparation for spacelab (astronomy), aeronomy, magnetosphere, and material science. Except for material science the scientific balloon projects are performed in the some scientific fields, but with a strong emphasis on astronomical research. It is tried to provide by means of tables a survey as complete as possible of the projects for the time since the last symposium in Elmau and of the plans for the future until 1981. The scientific balloon and sounding rocket projects form a small succesful part of the German space research programme. (author)

  3. Portal: Your Door to World Languages and Cultures

    Science.gov (United States)

    Elliott, Don; Lawton, Rachele

    2009-01-01

    Portal: Your Door to World Languages and Cultures was a series of public cultural events, in a variety of formats, created through a new partnership between the credit and continuing education (noncredit) foreign language programs at the Community College of Baltimore County (CCBC). Portal was designed to cultivate interest in foreign languages…

  4. Laser welding of balloon catheters

    Science.gov (United States)

    Flanagan, Aidan J.

    2003-03-01

    The balloon catheter is one of the principal instruments of non-invasive vascular surgery. It is used most commonly for angioplasty (and in recent years for delivering stents) at a multitude of different sites in the body from small arteries in the heart to the bilary duct. It is composed of a polymer balloon that is attached to a polymer shaft at two points called the distal and proximal bonds. The diverse utility of balloon catheters means a large range of component sizes and materials are used during production; this leads to a complexity of bonding methods and technology. The proximal and distal bonds have been conventionally made using cyanoacrylate or UV curing glue, however with performance requirements of bond strength, flexibility, profile, and manufacturing costs these bonds are increasingly being made by welding using laser, RF, and Hot Jaw methods. This paper describes laser welding of distal and proximal balloon bonds and details beam delivery, bonding mechanisms, bond shaping, laser types, and wavelength choice.

  5. Safety and effectiveness of gastric balloons associated with hypocaloric diet for the treatment of obesity.

    Science.gov (United States)

    de Castro, Maria Luisa; Morales, Maria Jose; Martínez-Olmos, Miguel A; Pineda, Juan R; Cid, Lucia; Estévez, Pamela; del-Campo, Victor; Rodríguez-Prada, J Ignacio

    2013-10-01

    intragastric balloons provide early satiety and thereby induce short-term weight loss. The aim of this study was to evaluate safety and short and medium-term effectiveness of gastric balloons associated to hypocaloric diet in obesity. from May 2004 to June 2011 91 obese patients, body mass index (BMI) 45.2 +/- 7.2 kg/m2 were prospectively followed after endoscopic implantation of a gastric balloon associated to restricted diet. Successful therapy was defined as percent loss of total weight (%LTW) > or = 5 % at six months after balloon placement and 6 and 12 months after their withdrawal. All analyses followed intention-to treat principles considering significant p-values or = 5 %. Short-term and medium-term effectiveness was negatively associated to obesity in first-grade relatives (p = 0.003 and p = 0.04). Higher weight loss 6 months after balloon placement independently predicted medium-term effectiveness (p = 0.0001). Mortality was absent but there were two spontaneous deflations of air-filled balloons and severe withdrawal difficulties in 8 patients, leading to surgery in one case. Retrieval complications associated to air-filled balloons (p = 0.0005). in obesity, effectiveness of gastric balloons associated to hypocaloric diet decreases over time.Complications occurred mainly in the retrieval endoscopic procedure and related to air-filled balloons.

  6. Deployment Instabilities of Lobed-Pumpkin Balloon

    Science.gov (United States)

    Nakashino, Kyoichi

    A lobed-pumpkin balloon, currently being developed in ISAS/JAXA as well as in NASA, is a promising vehicle for long duration scientific observations in the stratosphere. Recent ground and flight experiments, however, have revealed that the balloon has deployment instabilities under certain conditions. In order to overcome the instability problems, a next generation SPB called 'tawara' type balloon has been proposed, in which an additional cylindrical part is appended to the standard lobed-pumpkin balloon. The present study investigates the deployment stability of tawara type SPB in comparison to that of standard lobed-pumpkin SPB through eigenvalue analysis on the basis of finite element methods. Our numerical results show that tawara type SPB enjoys excellent deployment performance over the standard lobed-pumpkin SPBs.

  7. Gigantic balloon type artificial lightning generator

    Energy Technology Data Exchange (ETDEWEB)

    Horii; kenji

    1988-09-05

    This paper outlines a hot-air balloon type Van de Graaf 50-MV generator which can generate a 50,000,000 V, 0.2 to 0.3 coulomb artificial lightning comparable to natural lightning discharge and reports the results of investigation on discharging experiments conducted using this apparatus. The subjects covered are as follows: (1) Outline of the hot-air balloon type Van de Graaf 50-MV generator, (2) electric characteristics of the Van de Graaf 50-MV generator, (3) charge transfer with film and balloon charging, (4) the load of the balloon and buoyancy calculation, (5) leakage of charges, (6) study of charging experiments, and (7) evaluation of the apparatus and its method and problems to be solved. (4 figs, 4 tabs, 4 refs)

  8. Study of structural capacity and serviceability affecting the obstruction of residential door

    Directory of Open Access Journals (Sweden)

    Eric Forcael

    Full Text Available The last Chilean earthquake, occurred on February 27, 2010, allowed establishing important patterns of structural failures in reinforced concrete residential buildings; however, limited progress has been made in the study of basic standards of serviceability, such as obstruction of doors. Thus, this study focused on measuring the influence of design specifications and construction criteria of lintels and columns, in terms of obstruction of doors, considering capacity thresholds for certain levels of displacement. The study consisted of the design and construction of a full-scale prototype of a reinforced concrete frame, designed in accordance with all the ACI-318-08 requirements, taking into account typical aspects of geometry and materiality widely used by the real estate industry, for location and size of doors. In order to quantify the structural capacity of the prototype and to study the serviceability of the door, a quasi-static cyclic test was conducted, according to load and displacement protocols specified in FEMA 356 and FEMA 461, which was adjusted by using virtual models based on a static nonlinear analysis called "Pushover". This research verified that, for displacement levels even five times higher than those established by codes considered, the cracking degree was minimal and fully recoverable. It was also found the door evidenced malfunction when the displacements were greater than those specified by design only, validating a high degree of accomplishment of current codes, in terms of capacity and serviceability, when dealing with obstruction of residential doors.

  9. Overview of the NASA balloon R&D program

    Science.gov (United States)

    Smith, I. Steve, Jr.

    1994-01-01

    The catastrophic balloon failure during the first half of the 1980's identified the need for a comprehensive and continuing balloon research and development (R&D) commitment by NASA. Technical understanding was lacking in many of the disciplines and processes associated with scientific ballooning. A comprehensive balloon R&D plan was developed in 1986 and implemented in 1987. The objectives were to develop the understanding of balloon system performance, limitations, and failure mechanisms. The program consisted of five major technical areas: structures, performance and analysis, materials, chemistry and processing, and quality control. Research activitites have been conducted at NASA/Goddard Space Flight Center (GSFC)-Wallops Flight Facility (WFF), other NASA centers and government facilities, universities, and the balloon manufacturers. Several new and increased capabilities and resources have resulted from this activity. The findings, capabilities, and plan of the balloon R&D program are presented.

  10. Vertical sounding balloons for stratospheric photochemistry

    Science.gov (United States)

    Pommereau, J. P.

    The use of vertical sounding balloons for stratospheric photochemistry studies is illustrated by the use of a vertical piloted gas balloon for the search of NO2 diurnal variations. It is shown that the use of montgolfieres (hot air balloons) can enhance the vertical sounding technique. Particular attention is given to a sun-heated montgolfiere and to the more sophisticated infrared montgolfiere that is able to perform three to four vertical excursions per day and to remain aloft for weeks or months.

  11. TRANSPORT OF PATIENTS FOR PRIMARY PTCA FROM GENERAL HOSPITAL NOVO MESTO TO LJUBLJANA IN 2002

    Directory of Open Access Journals (Sweden)

    Renata Okrajšek

    2004-12-01

    Full Text Available Background. The treatment of acute coronary syndrome (ACS with ST-segment elevation with primary percutaneous transluminal coronary angioplasty (PTCA is the best way to treat these patients. Primary PTCA is also practicable with patients who are admitted into institution without catheter laboratory. The transport of patients into the tertiary institution is safe, but it is important to keep the time of ischemia as short as possible and to reach the time interval of door-balloon as recommended by the guidelines. The ACS patients with ST-segment elevation that were directed into General Hospital Novo mesto after examination at the internistic emergency department have been redirected to KC Ljubljana for realization of PTCA since October 2001.Methods. A prospective analysis of patients with ACS with STsegment elevation, who had been transferred from General Hospital Novo mesto to KC Ljubljana in the period from January 1, 2002 to December 31, 2002 to have a primary PTCA, was performed. The analysis comprised the following: the time interval of handling the patients at Internistic department of General Hospital Novo mesto, the time of transport of patients to Ljubljana and total time interval from the arrival of patients to General Hospital Novo mesto to the first inflation of balloon in Ljubljana. We monitored the complications that occurred during the treatment of the patients.Results. In the above mentioned period 29 patients (24 males and 5 females were transported from the General Hospital Novo mesto to the KC Ljubljana to have a primary PTCA performed. The total time interval measured between the patients’ arrival to General Hospital Novo mesto to the first inflation of balloon in Ljubljana in the year 2002 was 145 minutes, which is 17 minutes better than in the previous period. The time interval recommended by the guidelines was achieved with four patients.Conclusions. By recognizing the problems that had encountered with directing the

  12. Stability of Balloon-Retention Gastrostomy Tubes with Different Concentrations of Contrast Material: In Vitro Study

    International Nuclear Information System (INIS)

    Lopera, Jorge E.; Alvarez, Alex; Trimmer, Clayton; Josephs, Shellie; Anderson, Matthew; Dolmatch, Bart

    2009-01-01

    The purpose of this study was to determine the performance of two balloon-retention-type gastrostomy tubes when the balloons are inflated with two types of contrast materials at different concentrations. Two commonly used balloon-retention-type tubes (MIC and Tri-Funnel) were inflated to the manufacturer's recommended volumes (4 and 20 cm 3 , respectively) with normal saline or normal saline plus different concentrations of contrast material. Five tubes of each brand were inflated with normal saline and 0%, 25%, 50%, 75%, and 100% contrast material dilutions, using either nonionic hyperosmolar contrast, or nonionic iso-osmolar contrast. The tubes were submerged in a glass basin containing a solution with a pH of 4. Every week the tubes were visually inspected to determine the integrity of the balloons, and the diameter of the balloons was measured with a caliper. The tests were repeated every week for a total of 12 weeks. The MIC balloons deflated slightly faster over time than the Tri-Funnel balloons. The Tri-Funnel balloons remained relatively stable over the study period for the different concentrations of contrast materials. The deflation rates of the MIC balloons were proportionally related to the concentration of saline and inversely related to the concentration of the contrast material. At high contrast material concentrations, solidification of the balloons was observed. In conclusion, this in vitro study confirms that the use of diluted amounts of nonionic contrast materials is safe for inflating the balloons of two types of balloon-retention feeding tubes. High concentrations of contrast could result in solidification of the balloons and should be avoided.

  13. NASA Langley Research Center tethered balloon systems

    Science.gov (United States)

    Owens, Thomas L.; Storey, Richard W.; Youngbluth, Otto

    1987-01-01

    The NASA Langley Research Center tethered balloon system operations are covered in this report for the period of 1979 through 1983. Meteorological data, ozone concentrations, and other data were obtained from in situ measurements. The large tethered balloon had a lifting capability of 30 kilograms to 2500 meters. The report includes descriptions of the various components of the balloon systems such as the balloons, the sensors, the electronics, and the hardware. Several photographs of the system are included as well as a list of projects including the types of data gathered.

  14. Mars Solar Balloon Lander, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Solar Balloon Lander (MSBL) is a novel concept which utilizes the capability of solar-heated hot air balloons to perform soft landings of scientific...

  15. Clinical experience with the Monorail balloon catheter for coronary angioplasty.

    Science.gov (United States)

    Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W

    1988-01-01

    The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.

  16. Flow of pedestrians through narrow doors with different competitiveness

    International Nuclear Information System (INIS)

    Garcimartín, A; Pastor, J M; Zuriguel, I; Parisi, D R; Martín-Gómez, C

    2016-01-01

    We report a thorough analysis of the intermittent flow of pedestrians through a narrow door. The observations include five different sets of evacuation drills with which we have investigated the effect of door size and competitiveness on the flow dynamics. Although the outcomes are in general compatible with the existence of the faster-is-slower effect, the temporal evolution of the instantaneous flow rate provides evidence of new features. These stress the crucial role of the number of people performing the tests, which has an influence on the obtained results. Once the transients at the beginning and end of the evacuation are removed, we have found that the time lapses between the passage of two consecutive pedestrians display heavy-tailed distributions in all the scenarios studied. Meanwhile, the distribution of burst sizes decays exponentially; this can be linked to a constant probability of finding a long-lasting clog during the evacuation process. Based on these results, a discussion is presented on the caution that should be exercised when measuring or describing the intermittent flow of pedestrians through narrow doors. (paper: interdisciplinary statistical mechanics)

  17. Observations of volcanic plumes using small balloon soundings

    Science.gov (United States)

    Voemel, H.

    2015-12-01

    Eruptions of volcanoes are very difficult to predict and for practical purposes may occur at any time. Any observing system intending to observe volcanic eruptions has to be ready at any time. Due to transport time scales, emissions of large volcanic eruptions, in particular injections into the stratosphere, may be detected at locations far from the volcano within days to weeks after the eruption. These emissions may be observed using small balloon soundings at dedicated sites. Here we present observations of particles of the Icelandic Grimsvotn eruption at the Meteorological Observatory Lindenberg, Germany in the months following the eruption and observations of opportunity of other volcanic particle events. We also present observations of the emissions of SO2 from the Turrialba volcano at San Jose, Costa Rica. We argue that dedicated sites for routine observations of the clean and perturbed atmosphere using small sounding balloons are an important element in the detection and quantification of emissions from future volcanic eruptions.

  18. Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients.

    Directory of Open Access Journals (Sweden)

    Hee Young Cho

    Full Text Available The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation.We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL.Sixty-four patients (46.7% required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1% had placenta previa totalis. The overall success rate was 75% (48/64 for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all p<0.05. The drainage amount over 1 hour was 500 mL (20-1200 mL in the balloon failure group and 60 mL (5-500 mL in the balloon success group (p<0.01.Intrauterine tamponade with a Bakri balloon is an adequate adjunct management for postpartum hemorrhage following cesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance.

  19. Balloon-based adjuvant radiotherapy in breast cancer: comparison between {sup 99m}Tc and HDR {sup 192}Ir

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Tarcisio Passos Ribeiro de; Lima, Carla Flavia de; Cuperschmid, Ethel Mizrahy, E-mail: tprcampos@pq.cnpq.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2016-03-15

    Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with {sup 99m}Tc and balloon brachytherapy with high-dose-rate (HDR) {sup 192}Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and methods: simulations of implants with {sup 99m}Tc-filled and HDR {sup 192}Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: the {sup 99m}Tc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h{sup -1}.mCi{sup -1} and 0.190 cGyh{sup -1} at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh{sup -1}.mCi{sup -1}, respectively, for the HDR {sup 192}Ir balloon. An exposure time of 24 hours was required for the {sup 99m}Tc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR {sup 192}Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: temporary {sup 99m}Tc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR {sup 192}Ir balloon implantation, which is the current standard in clinical practice. (author)

  20. Use of monorail PTCA balloon catheter for local drug delivery.

    Science.gov (United States)

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  1. Certification and safety aspects relating to the transport of passengers on high altitude balloons in Europe

    Science.gov (United States)

    Schoenmaker, Annelie

    2014-07-01

    High-altitude balloons typically fly between 25 and 50 km in altitude, which, while below the Karman line of 100 km, is yet far above the altitudes typically flown by aircraft. For example, the highest-flying commercial aircraft - the Concorde - had a maximum cruising altitude of only 18 km. zero2infinity, a Spanish company, is currently developing a pressurized pod named “bloon” which will be capable of lifting six people, including two pilot crew members and four paying passengers, to an altitude of 36 km through the use of high-altitude balloons. The boundary between Airspace and Outer Space has never been legally defined, mostly because of the lack of activities taking place between the altitude where airplanes fly and the lowest orbiting spacecraft. High-altitude balloons do fly at these in-between altitudes and the prospect of commercializing access to these parts of the stratosphere poses some questions in a new light. Given the relatively low altitude at which they fly, it may well be that these types of balloons would be considered to operate exclusively within air space. However, given the technology involved in crewed high altitude balloon flights, which is more similar to spacecraft engineering than to traditional hot-air or gas ballooning, it is necessary to evaluate the various legal regimes, codes, and regulations that would apply to such flights, especially regarding licenses and liabilities. For high altitude balloon flights commencing in Europe, the European Aviation Safety Agency (EASA) would very likely be the competent certification or licensing agency for these flights, although there would likely be input from various national aviation authorities as well. However, because the European Commission (EC) has not yet issued regulations regarding commercial spaceflight, particularly the use of high altitude balloons, new rules and regulations governing such flights may still need to be drafted and promulgated. With the development of

  2. An unexpected knock on Corrigan’s secret door

    Science.gov (United States)

    Woywodt, Alexander

    2010-01-01

    Corrigan’s secret door describes a metaphorical escape route for busy physicians. The term was derived from the successful and exceptionally busy professional life of Irish physician Dominic John Corrigan (1802–80). It is claimed that Corrigan’s outpatient clinic was so busy that he required a secret door in his consulting rooms to escape from the ever-growing queue of eager patients. The origins of this charming story are unknown, and the door may have never existed. However, at present, Corrigan’s secret door is often quoted when busy physicians have their own little ways in surviving a stressful professional life. Generations of British-trained doctors have grown up with Corrigan’s secret door, as it was featured in the introduction of the Oxford Handbook of Clinical Medicine. Accordingly, trainees as well as more senior doctors are often reminded that having a ‘secret door’ is vital in surviving in the medical profession. My own escape is through classical music and the violoncello, in particular. As the name implies, my own secret door is normally invisible to colleagues and patients. This little article is about a patient who found me out, and a reflection on the role of classical music and the cello in my professional life. PMID:25984078

  3. COMPARISON OF RESULTS OF THERMAL TESTS OF BALCONY DOORS

    Directory of Open Access Journals (Sweden)

    Golubev Stanislav Sergeevich

    2012-10-01

    Full Text Available Results of thermal tests of balcony doors are presented in the article. In the course of the research project, two types of doors were tested. The first type represents a PVC frame door (width 82 mm; it has a triple glazing (4K-16Ar-4-16Ar-K4; its blank part represents a polystyrene sandwich panel (width 40 mm. The second type represents a PVC frame door (width 82 mm, that has a triple glazing (4K-16Ar-4-16Ar-K4 and composite PVC panels. The testing procedure and processing results are described in the article. The test has demonstrated that the thermal resistance value of the balcony door of the first type exceeds the thermal resistance value of the balcony door of the second type.

  4. Differentiating ST elevation myocardial infarction and nonischemic causes of ST elevation by analyzing the presenting electrocardiogram

    DEFF Research Database (Denmark)

    Jayroe, Jason B; Spodick, David H; Nikus, Kjell

    2008-01-01

    Guidelines recommend that patients with suggestive symptoms of myocardial ischemia and ST-segment elevation (STE) in > or =2 adjacent electrocardiographic leads should receive immediate reperfusion therapy. Novel strategies aimed to reduce door-to-balloon time, such as prehospital wireless...

  5. Characterizing the continuously acquired cardiovascular time series during hemodialysis, using median hybrid filter preprocessing noise reduction.

    Science.gov (United States)

    Wilson, Scott; Bowyer, Andrea; Harrap, Stephen B

    2015-01-01

    The clinical characterization of cardiovascular dynamics during hemodialysis (HD) has important pathophysiological implications in terms of diagnostic, cardiovascular risk assessment, and treatment efficacy perspectives. Currently the diagnosis of significant intradialytic systolic blood pressure (SBP) changes among HD patients is imprecise and opportunistic, reliant upon the presence of hypotensive symptoms in conjunction with coincident but isolated noninvasive brachial cuff blood pressure (NIBP) readings. Considering hemodynamic variables as a time series makes a continuous recording approach more desirable than intermittent measures; however, in the clinical environment, the data signal is susceptible to corruption due to both impulsive and Gaussian-type noise. Signal preprocessing is an attractive solution to this problem. Prospectively collected continuous noninvasive SBP data over the short-break intradialytic period in ten patients was preprocessed using a novel median hybrid filter (MHF) algorithm and compared with 50 time-coincident pairs of intradialytic NIBP measures from routine HD practice. The median hybrid preprocessing technique for continuously acquired cardiovascular data yielded a dynamic regression without significant noise and artifact, suitable for high-level profiling of time-dependent SBP behavior. Signal accuracy is highly comparable with standard NIBP measurement, with the added clinical benefit of dynamic real-time hemodynamic information.

  6. Optimizing logistics for balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices by doing away with the indwelling balloon: concept and techniques.

    Science.gov (United States)

    Saad, Wael E; Nicholson, David B

    2013-06-01

    Since the conception of balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices 25 years ago, the placement of an indwelling balloon for hours has been central to the BRTO procedure. Numerous variables and variations of the BRTO procedure have been described, including methods to reduce sclerosant, combining percutaneous transhepatic obliteration, varying sclerosant, and using multiple sclerosants within the same procedure. However, the consistent feature of BRTO has always remained the indwelling balloon. Placing an indwelling balloon over hours for the BRTO procedure is a logistical burden that taxes the interventional radiology team and hospital resources. Substituting the balloon with hardware (coils or Amplatzer vascular plugs [AVPs] or both) is technically feasible and its risks most likely correlate with gastrorenal shunt (GRS) size. The current authors use packed 0.018- or 0.035-in coils or both for small gastric variceal systems (GRS size A and B) and AVPs for GRS sizes up to size E (from size A-E). The current authors recommend an indwelling balloon (no hardware substitute) for very large gastric variceal system (GRS size F). Substituting the indwelling balloon for hardware in size F and potentially size E GRS can also be risky. The current article describes the techniques of placing up to 16-mm AVPs through balloon occlusion guide catheters and then deflating the balloon once it has been substituted with the AVPs. In addition, 22-mm AVPs can be placed through sheaths once the balloon occlusion catheters are removed to further augment the 16-mm Amplatzer occlusion. To date, there are no studies describing, let alone evaluating, the clinical feasibility of performing BRTO without indwelling balloons. The described techniques have been successfully performed by the current authors. However, the long-term safety and effectiveness of these techniques is yet to be determined. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Ballooning behavior in the golden orbweb spider Nephilapilipes (Araneae: Nephilidae

    Directory of Open Access Journals (Sweden)

    Vanessa M.J. Lee

    2015-01-01

    Full Text Available Ballooning, a mode of aerial dispersal in spiders, is an innate behavior that requires appropriate physiological and meteorological conditions. Although only rarely reported in the golden orbweb spiders, family Nephilidae, the large geographic distributions of most nephilids—in particular of Nephila species—would imply that these spiders likely routinely disperse by ballooning in spite of giant female sizes. Here we study ballooning behavior in the golden orbweb spider Nephila pilipes (Fabricius, 1793. Specifically, we test for the propensity of spiderlings to deploy ballooning as a dispersal mechanism. We subjected a total of 59 first-instar spiderlings to a wind experiment at two wind speeds (2.17 ± 0.02 m s-1 and 3.17 ± 0.02 m s-1 under laboratory conditions. Under an average wind speed of 3.17 m s-1, none of the spiderlings exhibited pre-ballooning or ballooning behavior. However, at an average wind speed of 2.17 m s-1, 53 (89.8% spiderlings showed pre-ballooning behavior, and 17 (32.1% of the pre-ballooners ultimately ballooned. Our results concur with prior reports on spiderlings of other families that pre-ballooning behavior is a requirement for ballooning to occur. Furthermore, although we cannot rule out other dispersal mechanisms such as synanthropic spread, our findings suggest that the widespread N. pilipes uses ballooning to colonize remote oceanic islands.

  8. Endoscopy-guided balloon dilation of benign anastomotic strictures after radical gastrectomy for gastric cancer.

    Science.gov (United States)

    Lee, Hyun Jik; Park, Wan; Lee, Hyuk; Lee, Keun Ho; Park, Jun Chul; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan; Noh, Sung Hoon

    2014-07-01

    The aim of this study was to evaluate the outcome of endoscopic dilation for benign anastomotic stricture after radical gastrectomy in gastric cancer patients. Gastric cancer patients who underwent endoscopic balloon dilation for benign anastomosis stricture after radical gastrectomy during a 6-year period were reviewed retrospectively. Twenty-one patients developed benign strictures at the site of anastomosis. The majority of strictures occurred within 1 year after surgery (95.2%). The median duration to stenosis after surgery was 1.70 months (range, 0.17 to 23.97 months). The success rate of the first endoscopic dilation was 61.9%. Between the restenosis group (n=8) and the no restenosis group (n=13), there were no significant differences in the body mass index (22.82 kg/m(2) vs 22.46 kg/m(2)), interval to symptom onset (73.9 days vs 109.3 days), interval to treatment (84.6 days vs 115.6 days), maximal balloon diameter (14.12 mm vs 15.62 mm), number of balloon dilation sessions (1.75 vs 1.31), location of gastric cancer or type of surgery. One patient required surgery because of stricture refractory to repeated dilation. Endoscopic dilation is a highly effective treatment for benign anastomotic strictures after radical gastrectomy for gastric cancer and should be considered a primary intervention prior to proceeding with surgical revision.

  9. Use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats: six cases (2005-2007).

    Science.gov (United States)

    Berent, Allyson C; Weisse, Chick; Todd, Kimberly; Rondeau, Mark P; Reiter, Alexander M

    2008-11-01

    To determine outcome associated with use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats. Retrospective case series. 3 dogs and 3 cats. All 6 animals had severe inspiratory stertor at initial examination. Two animals had no orifice present at the stenosis. Nasopharyngeal stenosis was diagnosed and stent size determined by use of computed tomography. A percutaneous transluminal angioplasty balloon premounted with a balloon-expandable metallic stent was placed over a guidewire, advanced through the stenotic lesion under fluoroscopic and rhinoscopic guidance, and dilated to restore patency. All animals had immediate resolution of clinical signs after stent placement. The procedure took a median of 38 minutes (range, 22 to 70 minutes). One animal with a stenosis located far caudally needed the tip of the stent resected because of hairball entrapment and exaggerated swallowing. Both animals without an orifice in the stenosis had tissue in-growth requiring a covered stent. All animals were reexamined 6 to 12 weeks after treatment via rhinoscopy, radiography, computed tomography, or a combination of techniques. All animals lacked signs of discomfort; 5 of 6 were breathing normally 12 to 28 months after the procedure. Transnasal balloon-expandable metallic stent placement may represent a rapid, safe, noninvasive, and effective treatment in animals with nasopharyngeal stenosis. If the stenosis is extremely caudal in the nasopharynx, serial balloon dilatation might be considered prior to stent placement. A covered stent should be considered initially if the stenosis is completely closed.

  10. A Foot Operated Timeout Room Door Latch.

    Science.gov (United States)

    Foxx, R. M.; And Others

    1982-01-01

    This report describes the design and implementation of a foot operated timeout room door latch that permits staff members to maintain a misbehaving retarded individual in timeout without locking the door. Use of the latch also frees the staff member involved to record behavioral observations or reinforce appropriate behavior. (Author)

  11. Detecting Signage and Doors for Blind Navigation and Wayfinding.

    Science.gov (United States)

    Wang, Shuihua; Yang, Xiaodong; Tian, Yingli

    2013-07-01

    Signage plays a very important role to find destinations in applications of navigation and wayfinding. In this paper, we propose a novel framework to detect doors and signage to help blind people accessing unfamiliar indoor environments. In order to eliminate the interference information and improve the accuracy of signage detection, we first extract the attended areas by using a saliency map. Then the signage is detected in the attended areas by using a bipartite graph matching. The proposed method can handle multiple signage detection. Furthermore, in order to provide more information for blind users to access the area associated with the detected signage, we develop a robust method to detect doors based on a geometric door frame model which is independent to door appearances. Experimental results on our collected datasets of indoor signage and doors demonstrate the effectiveness and efficiency of our proposed method.

  12. Balloon pulmonary valvotomy – Not just a simple balloon dilatation

    Directory of Open Access Journals (Sweden)

    Subhendu Mohanty

    2014-07-01

    Full Text Available Balloon pulmonary valvotomy is the preferred mode of treatment in patients with isolated pulmonary valvar stenosis and has shown good long term results. It is generally considered a safe procedure with few complications. There have been however, case reports of potentially fatal acute severe pulmonary edema occurring after the procedure in some patients. The cause of this complication and its pathophysiology is still not clear. Its occurrence is also infrequent with less than 5 cases reported till now. We report a case of pulmonary valvar stenosis which developed acute severe refractory pulmonary edema immediately after balloon pulmonary valvotomy.

  13. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. From the box press a valve plate is suspended by four linkage bars, one for each corner. Each linkage bar is provided with two wheels which are respectively mounted at the connections with the box press and the valve plate. The wheels are carried on the horizontal grooves formed in a door valve casing. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing while the valve plate does not contact the casing. When the box press reaches the home position, the wheels drop into the recesses which are disposed at the ends of the grooves, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not over other parts. (Yamaguchi, T.)

  14. TLE Balloon experiment campaign carried out on 25 August 2006 in Japan

    Science.gov (United States)

    Takahashi, Y.; Chikada, S.; Yoshida, A.; Adachi, T.; Sakanoi, T.

    2006-12-01

    The balloon observation campaign for TLE and lightning study was carried out 25 August 2006 in Japan by Tohoku University, supported by JAXA. The balloon was successfully launched at 18:33 LT at Sanriku Balloon Center of JAXA located in the east coast of northern part of Japan (Iwate prefecture). Three types of scientific payloads were installed at the 1 m-cubic gondola, that is, 3-axis VLF electric filed antenna and receiver (VLFR), 4 video frame CCD cameras (CCDI) and 2-color photometer (PM). The video images were stored in 4 HD video recorders, which have 20GB memories respectively, at 30 frames/sec and VLFR and PM data were put into digital data recorder with 30 GB memory at sampling rate of 100 kHz. The balloon floated at the altitude of 13 km until about 20:30 LT, going eastward and went up to 26 km at a distance of 130 km from the coast. And it went back westward at the altitude of 26 km until midnight. The total observation period is about 5 hours. Most of the equipments worked properly except for one video recorder. Some thunderstorms existed within the direct FOV from the balloon in the range of 400-600 km and more than about 400 lightning flashes were recorded as video images. We confirmed that, at least, one sprite halo was captured by CCDI which occurred in the oceanic thunderstorm at a distance of about 500 km from balloon. This is the first TLE image obtained by a balloon-borne camera. Simultaneous measurements of VLF sferics and lightning/TLE images will clarify the role of intracloud (IC) currents in producing and/or modulating TLEs as well as cloud-to-ground discharges (CG). Especially the effect of horizontal components will be investigated in detail, which cannot be detected on the ground, to explain the unsolved properties of TLEs, such as long time delay of TLE from the timing of stroke and large horizontal displacement between CG and TLEs.

  15. Simulating clefts in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank; Brakke, Kenneth

    2010-02-01

    The geometry of a large axisymmetric balloon with positive differential pressure, such as a sphere, leads to very high film stresses. These stresses can be significantly reduced by using a tendon re-enforced lobed pumpkin-like shape. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin shape, including the constant bulge angle (CBA) design, the constant bulge radius (CBR) design, CBA/CBR hybrids, and NASA’s recent constant stress (CS) design. Utilizing a hybrid CBA/CBR pumpkin design, Flight 555-NT in June 2006 formed an S-cleft and was unable to fully deploy. In order to better understand the S-cleft phenomenon, a series of inflation tests involving four 27-m diameter 200-gore pumpkin balloons were conducted in 2007. One of the test vehicles was a 1/3-scale mockup of the Flight 555-NT balloon. Using an inflation procedure intended to mimic ascent, the 1/3-scale mockup developed an S-cleft feature strikingly similar to the one observed in Flight 555-NT. Our analysis of the 1/3-scale mockup found it to be unstable. We compute asymmetric equilibrium configurations of this balloon, including shapes with an S-cleft feature.

  16. 46 CFR 170.270 - Door design, operation, installation, and testing.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Door design, operation, installation, and testing. 170..., operation, installation, and testing. (a) Each Class 1 door must have a quick action closing device... the welding process so that the door frame is not distorted. (e) For each watertight door which is in...

  17. Particle Astrophysics in NASA's Long Duration Balloon Program

    International Nuclear Information System (INIS)

    Gorham, Peter W.

    2013-01-01

    A century after Viktor Hess' discovery of cosmic rays, balloon flights still play a central role in the investigation of cosmic rays over nearly their entire spectrum. We report on the current status of NASA balloon program for particle astrophysics, with particular emphasis on the very successful Antarctic long-duration balloon program, and new developments in the progress toward ultra-long duration balloons

  18. Development of a Super-Pressure Balloon with an Improved Design

    Science.gov (United States)

    Izutsu, Naoki; Akita, Daisuke; Fuke, Hideyuki; Iijima, Issei; Kato, Yoichi; Kawada, Jiro; Matsushima, Kiyoho; Matsuzaka, Yukihiko; Mizuta, Eiichi; Nakada, Takashi; Nonaka, Naoki; Saito, Yoshitaka; Takada, Atsushi; Tamura, Keisuke; Yamada, Kazuhiko; Yoshida, Tetsuya

    A zero-pressure balloon used for scientific observation in the stratosphere has an unmanageable limitation that its floating altitude decreases during a nighttime because of temperature drop of the lifting gas. Since a super-pressure balloon may not change its volume, the lifetime can extend very long. We had introduced so called the ‘lobed-pumpkin’ type of super-pressure balloon that can realize a full-scale long-duration balloon and it will be in practical use in the very near future. As for larger super-pressure balloons, however, we still have some potential difficulties to be resolved. We here propose a new design suitable for a larger super-pressure balloon, which is roughly ‘lobed pumpkin with lobed cylinder’ and can adapt a single design for balloons of a wide range of volumes. Indoor inflation tests were successfully carried out with balloons designed and made by the method. It has been shown that the limit of the resisting pressure differential for a new designed balloon is same as that of a normal lobed-pumpkin balloon.

  19. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  20. Contura Multi-Lumen Balloon Breast Brachytherapy Catheter: Comparative Dosimetric Findings of a Phase 4 Trial

    Energy Technology Data Exchange (ETDEWEB)

    Arthur, Douglas W., E-mail: darthur@mcvh-vcu.edu [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States); Vicini, Frank A. [Michigan Healthcare Professionals/21st Century Oncology, Farmington Hills, Michigan (United States); Todor, Dorin A. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States); Julian, Thomas B. [Allegheny General Hospital, Temple University School of Medicine, Pittsburgh, Pennsylvania (United States); Cuttino, Laurie W.; Mukhopadhyay, Nitai D. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States)

    2013-06-01

    Purpose: Final dosimetric findings of a completed, multi-institutional phase 4 registry trial using the Contura Multi-Lumen Balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer are presented. Methods and Materials: Three dosimetric plans with identical target coverage were generated for each patient for comparison: multilumen multidwell (MLMD); central-lumen multidwell (CLMD); and central-lumen single-dwell (CLSD) loading of the Contura catheter. For this study, a successful treatment plan achieved ideal dosimetric goals and included the following: ≥95% of the prescribed dose (PD) covering ≥95% of the target volume (TV); maximum skin dose ≤125% of the PD; maximum rib dose ≤145% of the PD; and V150 ≤50 cc and V200 ≤10 cc. Results: Between January 2008 and February 2011, 23 institutions participated. A total of 318 patients were available for dosimetric review. Using the Contura MLB, all dosimetric criteria were met in 78.93% of cases planned with MLMD versus 55.38% with the CLMD versus 37.66% with the CLSD (P≤.0001). Evaluating all patients with the full range of skin to balloon distance represented, median maximum skin dose was reduced by 12% and median maximum rib dose by 13.9% when using MLMD-based dosimetric plans compared to CLSD. The dosimetric benefit of MLMD was further demonstrated in the subgroup of patients where skin thickness was <5 mm, where MLMD use allowed a 38% reduction in median maximum skin dose over CLSD. For patients with rib distance <5 mm, the median maximum rib dose reduction was 27%. Conclusions: Use of the Contura MLB catheter produced statistically significant improvements in dosimetric capabilities between CLSD and CLMD treatments. This device approach demonstrates the ability not only to overcome the barriers of limited skin thickness and close rib proximity, but to consistently achieve a higher standard of dosimetric planning goals.

  1. Contura Multi-Lumen Balloon breast brachytherapy catheter: comparative dosimetric findings of a phase 4 trial.

    Science.gov (United States)

    Arthur, Douglas W; Vicini, Frank A; Todor, Dorin A; Julian, Thomas B; Cuttino, Laurie W; Mukhopadhyay, Nitai D

    2013-06-01

    Final dosimetric findings of a completed, multi-institutional phase 4 registry trial using the Contura Multi-Lumen Balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer are presented. Three dosimetric plans with identical target coverage were generated for each patient for comparison: multilumen multidwell (MLMD); central-lumen multidwell (CLMD); and central-lumen single-dwell (CLSD) loading of the Contura catheter. For this study, a successful treatment plan achieved ideal dosimetric goals and included the following: ≥ 95% of the prescribed dose (PD) covering ≥ 95% of the target volume (TV); maximum skin dose ≤ 125% of the PD; maximum rib dose ≤ 145% of the PD; and V150 ≤50 cc and V200 ≤ 10 cc. Between January 2008 and February 2011, 23 institutions participated. A total of 318 patients were available for dosimetric review. Using the Contura MLB, all dosimetric criteria were met in 78.93% of cases planned with MLMD versus 55.38% with the CLMD versus 37.66% with the CLSD (P ≤.0001). Evaluating all patients with the full range of skin to balloon distance represented, median maximum skin dose was reduced by 12% and median maximum rib dose by 13.9% when using MLMD-based dosimetric plans compared to CLSD. The dosimetric benefit of MLMD was further demonstrated in the subgroup of patients where skin thickness was <5 mm, where MLMD use allowed a 38% reduction in median maximum skin dose over CLSD. For patients with rib distance <5 mm, the median maximum rib dose reduction was 27%. Use of the Contura MLB catheter produced statistically significant improvements in dosimetric capabilities between CLSD and CLMD treatments. This device approach demonstrates the ability not only to overcome the barriers of limited skin thickness and close rib proximity, but to consistently achieve a higher standard of dosimetric planning goals. Copyright © 2013 Elsevier Inc. All rights

  2. Impact of mobile intensive care unit use on total ischemic time and clinical outcomes in ST-elevation myocardial infarction patients - real-world data from the Acute Coronary Syndrome Israeli Survey.

    Science.gov (United States)

    Koifman, Edward; Beigel, Roy; Iakobishvili, Zaza; Shlomo, Nir; Biton, Yitschak; Sabbag, Avi; Asher, Elad; Atar, Shaul; Gottlieb, Shmuel; Alcalai, Ronny; Zahger, Doron; Segev, Amit; Goldenberg, Ilan; Strugo, Rafael; Matetzky, Shlomi

    2017-01-01

    Ischemic time has prognostic importance in ST-elevation myocardial infarction patients. Mobile intensive care unit use can reduce components of total ischemic time by appropriate triage of ST-elevation myocardial infarction patients. Data from the Acute Coronary Survey in Israel registry 2000-2010 were analyzed to evaluate factors associated with mobile intensive care unit use and its impact on total ischemic time and patient outcomes. The study comprised 5474 ST-elevation myocardial infarction patients enrolled in the Acute Coronary Survey in Israel registry, of whom 46% ( n=2538) arrived via mobile intensive care units. There was a significant increase in rates of mobile intensive care unit utilization from 36% in 2000 to over 50% in 2010 ( pcare unit use were Killip>1 (odds ratio=1.32, pcare units benefitted from increased rates of primary reperfusion therapy (odds ratio=1.58, pcare unit benefitted from shorter median total ischemic time compared with non-mobile intensive care unit patients (175 (interquartile range 120-262) vs 195 (interquartile range 130-333) min, respectively ( pcare unit use was the most important predictor in achieving door-to-balloon time care unit group (odds ratio=0.79, 95% confidence interval (0.66-0.94), p=0.01). Among patients with ST-elevation myocardial infarction, the utilization of mobile intensive care units is associated with increased rates of primary reperfusion, a reduction in the time interval to reperfusion, and a reduction in one-year adjusted mortality.

  3. Balloon launching station, Mildura, Victoria

    International Nuclear Information System (INIS)

    The Mildura Balloon Launching Station was established in 1960 by the Department of Supply (now the Department of Manufacturing Industry) on behalf of the United States Atomic Energy Commission (USAEC) to determine the content of radioactive material in the upper atmosphere over Australia. The Station location and layout, staffing, balloon launching equipment, launching, tracking and recovery are described. (R.L.)

  4. Ballooning mode stabilization by moderate sheared rotation

    International Nuclear Information System (INIS)

    Hameiri, E.

    1996-01-01

    Sheared toroidal plasma rotation has been known for some time to have a stabilizing effect on the ballooning modes. A recent calculation showed that a large flow shear, with dΩ/dq of the order of the Alfven toroidal frequency, can stabilize the ballooning modes. This latest result is, in fact, not so optimistic. For observed flows with Mach number of order unity one gets dΩ/dq smaller by a factor O(√β) from the required level (if the flow shear length is of the same order as the magnetic shear length). Moreover, the calculation does not take into account a possibly large transient growth of the mode amplitude due to its Floquet structures We show here that, in fact, there is a general tendency of the ballooning mode to stabilize as soon as the flow shear dΩ/dq exceeds the (O√β smaller) open-quotes slowclose quotes magnetosonic wave frequency. Our analysis is perturbative, where the small parameter is related to the small coupling between the slow and Alfven waves-as is the case in a high aspect-ratio tokamak. (In the perturbation it is important to take the Hamiltonian nature of the governing equations into account.) Moreover, our results apply to the relevant transient growth of the mode amplitude

  5. Scientific ballooning. Proceedings. PSB Meeting of the COSPAR Panel on Technical Problems Related to Scientific Ballooning which was held during the Thirtieth COSPAR Scientific Assembly, Hamburg (Germany), 11 - 21 Jul 1994.

    Science.gov (United States)

    Riedler, W.; Torkar, K.

    1996-05-01

    This issue is grouped into sections on materials, design, performance and analysis of balloons, reviews of major national and international balloon programmes, novel instrumentation and systems for scientific ballooning, and selected recent scientific observations.

  6. Keys to Achieving Target First Medical Contact to Balloon Times and Bypassing Emergency Department More Important Than Distance

    Directory of Open Access Journals (Sweden)

    Saad Ezad

    2018-01-01

    Full Text Available Background. Australian guidelines advocate primary percutaneous coronary intervention (PPCI as the reperfusion strategy of choice for ST elevation myocardial infarction (STEMI in patients in whom it can be performed within 90 minutes of first medical contact; otherwise, fibrinolytic therapy is preferred. In a large health district, the reperfusion strategy is often chosen in the prehospital setting. We sought to identify a distance from a PCI centre, which made it unlikely first medical contact to balloon time (FMCTB of less than 90 minutes could be achieved in the Hunter New England health district and to identify causes of delay in patients who were triaged to a PPCI strategy. Methods and Results. We studied 116 patients presenting via the ambulance service with STEMI from January 2016 to December 2016. In patients who were taken directly to the cardiac catheterisation lab, a maximum distance of 50 km from hospital resulted in 75% of patients receiving PCI within 90 minutes and approximately 95% of patients receiving PCI within 120 minutes. Patients who bypassed the emergency department (ED were significantly more likely to have FMCTB of less than 90 minutes (p<0.001 despite having a longer travel distance (28.5 km versus 17.4 km, p<0.001. Patients transiting via the ED were significantly more likely to present out of hours (60 versus 24.2% p<0.001. Conclusions. Patients who do not bypass the ED have a longer FMCTB across all spectrum of distances from the PCI centre; therefore, bypassing the ED is key to achieving target FMCTB times. Using a cutoff distance of 50 km may reduce human error in estimating travel time to our PCI centre and thereby identifying patients who should receive prehospital thrombolysis.

  7. A New Type of Captive Balloon for Vertical Meteorological Observation in Urban Area

    Science.gov (United States)

    Nakamura, M.; Sakai, S.; Ono, K.

    2010-12-01

    Many meteorological observations in urban area have been made in recent years in order to investigate the mechanism of heat island. However, there are few data of cooling process in urban area. For this purpose, high density observations in both space and time are required. Generally vertical meteorological observations can be made by towers, radars, balloons. These methods are limited by urban area conditions. Among these methods, a captive balloon is mainly used to about a hundred meter from ground in a vertical meteorological observation. Small airships called kytoons or advertising balloons, for example. Conventional balloons are, however, influenced by the wind and difficult to keep the specified position. Moreover, it can be dangerous to conduct such observations in the highly build-up area. To overcome these difficulties, we are developing a new type of captive balloon. It has a wing form to gain lift and keep its position. It is also designed small to be kept in a carport. It is made of aluminum film and polyester cloth in order to attain lightweight solution. We have tried floating a balloon like NACA4424 for several years. It was difficult to keep a wing form floating up over 100 meters from ground because internal pressure was decreased by different temperature. The design is changed in this year. The balloon that has wing form NACA4415 is similar in composition to an airplane. It has a big gasbag with airship form and two wing form. It is able to keep form of a wing by high internal pressure. We will report a plan for the balloon and instances of some observations.

  8. Stability of the pumpkin balloon

    Science.gov (United States)

    Baginski, Frank

    A large axisymmetric balloon with positive differential pressure, e.g., a sphere, leads to high film stresses. These can be significantly reduced by using a lobed pumpkin-like shape re-enforced with tendons. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin-shape at full inflation, including the constant bulge angle (CBA) design and the constant bulge radius (CBR) design. The authors and others have carried out stability studies of CBA and CBR designs and found instabilities under various conditions. While stability seems to be a good indicator of deployment problems for large balloons under normal ascent conditions, one cannot conclude that a stable design will deploy reliably. Nevertheless, stability analysis allows one to quantify certain deployment characteristics. Ongoing research by NASA's Balloon Program Office utilizes a new design approach developed by Rodger Farley, NASA/GSFC, that takes into account film and tendon strain. We refer to such a balloon as a constant stress (CS) pumpkin design. In June 2006, the Flight 555-NT balloon (based on a hybrid CBR/CBA design) developed an S-cleft and did not deploy. In order to understand the S-cleft phenomena and study a number of aspects related to the CS-design, a series of inflation tests were conducted at TCOM, Elizabeth City, NC in 2007. The test vehicles were 27 meter diameter pumpkins distinguished by their respective equatorial bulge angles (BA). For example, BA98 indicates an equatorial bulge angle of 98° . BA90, BA55, and BA00 are similarly defined. BA98 was essentially a one-third scale version of of the Flight 555 balloon (i.e., 12 micron film instead of 38.1 micron, mini-tendons, etc.). BA90 and BA55 were Farley CS-designs. BA00 was derived from the BA55 design so that a flat chord spanned adjacent tendons. In this paper, we will carry out stability studies of BA98, BA90, BA55, and BA00. We discuss the deployment problem of pumpkin balloons in light of 2007 inflation

  9. F-door spaces and F-submaximal spaces

    Directory of Open Access Journals (Sweden)

    Lobna Dridi

    2013-04-01

    Full Text Available Submaximal spaces and door spaces play an enigmatic role in topology. In this paper, reinforcing this role, we are concerned with reaching two main goals: The first one is to characterize topological spaces X such that F(X is a submaximal space (resp., door space for some covariant functor Ff rom the category Top to itself. T0, and FH functors are completely studied. Secondly, our interest is directed towards the characterization of maps f given by a flow (X, f in the category Set, such that (X,P(f is submaximal (resp., door where P(f is a topology on X whose closed sets are exactly the f-invariant sets.

  10. Balloon cell nevus of the iris.

    Science.gov (United States)

    Morcos, Mohib W; Odashiro, Alexandre; Bazin, Richard; Pereira, Patricia Rusa; O'Meara, Aisling; Burnier, Miguel N

    2014-12-01

    Balloon cell nevus is a rare histopathological lesion characterized by a predominance of large, vesicular and clear cells, called balloon cells. There is only 1 case of balloon cell nevus of the iris reported in the literature. A 55 year-old man presented a pigmented elevated lesion in the right iris since the age of 12 years old. The lesion had been growing for the past 2 years and excision was performed. Histopathological examination showed a balloon cell nevus composed of clear and vacuolated cells without atypia. A typical spindle cell nevus of the iris was also observed. The differential diagnosis included xanthomatous lesions, brown adipocyte or other adipocytic lesions, clear cell hidradenoma, metastatic clear cell carcinoma of the kidney and clear cell sarcoma. The tumor was positive for Melan A, S100 protein and HMB45. Balloon cell nevus of the iris is rare but should be considered in the differential diagnosis of melanocytic lesions of the iris. Copyright © 2014 Elsevier GmbH. All rights reserved.

  11. Balloon dilatation of ureteric strictures.

    Directory of Open Access Journals (Sweden)

    Punekar S

    2000-01-01

    Full Text Available AIMS: Evaluation of dilatation as a minimally invasive technique for the treatment of ureteric strictures. MATERIAL AND METHODS: We evaluated this technique in 16 patients with ureteric and secondary pelviureteric junction strictures from June 1998. Of these, 7 were men and 9 were women. The age range was from 14 to 40 years. RESULTS: Balloon dilatation was successful in 69% of patients. Strictures secondary to previous surgery had nearly 100% success. Of the 8 cases diagnosed as genitourinary tuberculosis, success rate was 50%. CONCLUSIONS: Factors affecting success of balloon dilatation are: a age of the stricture b length of the stricture and c etiology of the stricture. In a select group of patients with fresh post-operative or post-inflammatory strictures, balloon dilatation may be an attractive alternative to surgery.

  12. The Ins and Outs of Modern Doors.

    Science.gov (United States)

    College Planning & Management, 1999

    1999-01-01

    Discusses the qualities and trends in modern metal doors for educational facilities that include fire protection and sound-control attributes. Important differences in door manufacturing methods and materials are addressed and sound-transmission class values, ratings, and rating descriptions are listed. (GR)

  13. Percutaneous balloon dilation of pulmonary stenosis

    International Nuclear Information System (INIS)

    Hua Yangde; Huang Ming; Li Jinkang; Qian Jinqing; Chen Xiuyu; Yang Siyuan

    2003-01-01

    Objective: Review our experience of balloon dilation of valvular pulmonary stenosis in 32 cases. Methods: Totally 32 cases of pulmonary stenosis admitted from 1995-2001 with age of 1.5-13 yrs mean 6.8. Diagnosis was made by clinical manifestations, EKG, ECHO and angiocardiography. Results: Before dilation, the mean systolic pressure of right ventricle was (93.5 ± 28.5) mmHg, after the procedure it reduced to (42 ± 9.0) mmHg. The pressure gradient between right ventricle and pulmonary artery before dilation was (76 ± 30) mmHg and become (24.5 ± 8.5) mmHg after dilation. The gradient pressure after dilation was less than 25 mmHg in 90.6% cases. A case of Noonan syndrome showed no response to balloon dilation and died during valvulectomy from accompanying left ventricular cardiomyopathy. Conclusions: Balloon dilation of valvular pulmonary stenosis is effective and safe. The selection of proper diameter of pulmonary valvular rings and sized of the balloon are the major factors

  14. Does water-perfused catheter overdiagnose anismus compared to balloon probe?

    Science.gov (United States)

    Savoye, G; Leroi, A M; Bertot-Sassigneux, P; Touchais, J Y; Devroede, G; Denis, P

    2002-12-01

    The purpose of this study was to compare the manometric assessment of straining effort as if to defecate and rectoanal inhibitory reflex obtained with a rectosphincteric balloon probe and with a water-perfused catheter in the same subject. Twelve healthy volunteers underwent two manometric assessments of anal sphincter function and electromyographic (EMG) surface recordings. one with a rectosphincteric balloon and one with a water-perfused catheter, 7 days apart in random order. Increased EMG activity in the external anal sphincter in the midst of the rectoanal inhibitory reflex (P anismus, particularly if pelvic floor EMG is only taken into account for the diagnosis of anismus.

  15. Developing International Standards for Meteorological Balloon to Facilitate Industrial Progress

    Institute of Scientific and Technical Information of China (English)

    Deng Yizhi

    2011-01-01

    Meteorological balloon is made of natural rubber latex with a special process.On natural conditions,it carries the air sounding instrument into the high air to detect the meteorological elements in the air.As a means of delivery used in the aerological sounding,it is widely used in the meteorological,sailing,aeronautical,aerospace and other fields,and plays an extremely important role in the weather report,disaster prevention,disaster relief,guaranteeing ships and aircrafts to leave ports safely,and scientific research in relevant spaces,etc.Especially,the role of meteorological balloons is not ignorable in the forecast of extremely adverse weather frequently occurring around the world in recent years.

  16. Properties of ballooning modes in the Heliotron configurations

    International Nuclear Information System (INIS)

    Nakajima, N.; Hudson, S.R.; Hegna, C.C.

    2005-01-01

    The stability of ballooning modes is influenced by the local and global magnetic shear and local and global magnetic curvature so significantly that it is fairly difficult to get those general properties in the three dimensional configurations with strong flexibility due to the external coil system. In the case of the planar axis heliotron configurations allowing a large Shafranov shift, like LHD, properties of the high-mode-number ballooning modes have been intensively investigated. It has been analytically shown that the local magnetic shear comes to disappear in the stellarator-like global magnetic shear region, as the Shafranov shift becomes large. Based on this mechanism and the characteristics of the local and global magnetic curvature, it is numerically shown that the destabilized ballooning modes have strong three-dimensional properties (both poloidal and toroidal mode couplings) in the Mercier stable region, and that those are fairly similar to ballooning modes in the axisymmetric system in the Mercier unstable region. As is well known, however, no quantization condition is applicable to the ballooning modes in the three-dimensional system without symmetry, and so the results of the high-mode-number ballooning modes in the covering space had to be confirmed in the real space. Such a confirmation has been done in the Mercier stable region and also in the Mercier unstable region by using three dimensional linearized ideal MHD stability code cas3d. Confirming the relation between high-mode-number ballooning analyses by the global mode analyses, the method of the equilibrium profile variations has been developed in the tree dimensional system, giving dt/dψ - dP/dψ stability diagram corresponding to the s - α diagram in tokamaks. This method of profile variation are very powerful to investigate the second stability of high-mode-number ballooning modes and has been more developed. Recently it has been applied to the plasma in the inward-shifted LHD

  17. Functional Median Polish

    KAUST Repository

    Sun, Ying

    2012-08-03

    This article proposes functional median polish, an extension of univariate median polish, for one-way and two-way functional analysis of variance (ANOVA). The functional median polish estimates the functional grand effect and functional main factor effects based on functional medians in an additive functional ANOVA model assuming no interaction among factors. A functional rank test is used to assess whether the functional main factor effects are significant. The robustness of the functional median polish is demonstrated by comparing its performance with the traditional functional ANOVA fitted by means under different outlier models in simulation studies. The functional median polish is illustrated on various applications in climate science, including one-way and two-way ANOVA when functional data are either curves or images. Specifically, Canadian temperature data, U. S. precipitation observations and outputs of global and regional climate models are considered, which can facilitate the research on the close link between local climate and the occurrence or severity of some diseases and other threats to human health. © 2012 International Biometric Society.

  18. Balloon dilation and airway stenting for benign and malignant tracheal stenosis

    International Nuclear Information System (INIS)

    Guo Jianhai; Yang Renjie; Zhang Hongzhi

    2009-01-01

    Objective: To assess the effectiveness of balloon dilation and airway stenting performed under fluoroscopic guidance for the treatment of benign and malignant tracheal stenosis. Methods: Under fluoroscopic guidance, balloon dilation and airway stenting were performed in 45 patients with tracheobronchial stricture. Of the 45 patients,malignant tracheal stenosis was seen in 37, including mediastinal nodal metastases (n=14), esophageal carcinoma (n=13), lung carcinoma (n= 4), adenocarcinoma of bronchus (n=3), lymphoma (n=2) and laryngocarcinoma (n=1), and benign tracheal stenosis was seen in 8, including endobronchial tuberculosis (n=6), retrosternal thyroid adenoma (n=1) and endotracheal intubation (n=1). Airway stenting with self-expandable metal stent was employed in 38 patients and balloon dilation in 7 patients. All the procedures were performed under fluoroscopic guidance. Results: A total of 53 self-expandable metal stents was implanted in 38 patients. The clinical symptoms were immediately relived after the procedure in all patients except for one patient who died from choking of sputum. No stent migration was observed. Restenosis developed in 4 patients, which was successfully treated with repeated stenting and balloon dilation. Nineteen times of balloon dilation procedure were accomplished in 7 patients. Marked remission of clinical symptoms was seen in most cases. During a follow-up period (ranged from 0 to 124 months with a mean of 24.5 months) 31 patients died. Conclusion: For both benign and malignant tracheal stenosis, balloon dilation with airway stenting performed under fluoroscopic guidance is a safe and efficient therapy with instant curative effect in relieving clinical symptoms. (authors)

  19. 16 CFR 1211.13 - Inherent force activated secondary door sensors.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Inherent force activated secondary door sensors. 1211.13 Section 1211.13 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT... across the door so that the axis is perpendicular to the plane of the door. See Figure 6 of this part...

  20. Development of the automated bunker door by using a microcontroller-system

    Science.gov (United States)

    Ahmad, M. A.; Leo, K. W.; Mohamad, G. H. P.; Ahmad, A.; Hashim, S. A.; Chulan, R. M.; Baijan, A. H.

    2018-01-01

    The new low energy electron beam accelerator bunker was designed and built locally to allocate a 500 keV electron beam accelerator at Block 43T in Malaysian Nuclear Agency. This bunker is equipped with a locally made radiation shielding door of 10 tons. Originally, this door is moving manually by a wheel and fitted with a gear system. However, it is still heavy and need longer time to operate it manually. To overcome those issues, a new automated control system has been designed and developed. In this paper, the complete steps and design of automated control system based on the microcontroller (PIC16F84A) is described.

  1. Diplopie door monovisie

    NARCIS (Netherlands)

    Jorien Schouten; Louise Helmer

    2017-01-01

    Doelstelling: In kaart brengen van de risicofactoren voor het ontwikkelen van binoculaire diplopie na conventionele monovisie door middel van contactlenzen of refractiechirurgie bij presbyopen. Methode: Voor deze literatuurstudie is in maart 2017 gezocht in databanken Pubmed, ScienceDirect en Google

  2. Atmospheric Sampling of Aerosols to Stratospheric Altitudes using High Altitude Balloons

    Science.gov (United States)

    Jerde, E. A.; Thomas, E.

    2010-12-01

    Although carbon dioxide represents a long-lived atmospheric component relevant to global climate change, it is also understood that many additional contributors influence the overall climate of Earth. Among these, short-lived components are more difficult to incorporate into models due to uncertainties in the abundances of these both spatially and temporally. Possibly the most significant of these short-lived components falls under the heading of “black carbon” (BC). There are numerous overlapping definitions of BC, but it is basically carbonaceous in nature and light absorbing. Due to its potential as a climate forcer, an understanding of the BC population in the atmosphere is critical for modeling of radiative forcing. Prior measurements of atmospheric BC generally consist of airplane- and ground-based sampling, typically below 5000 m and restricted in time and space. Given that BC has a residence time on the order of days, short-term variability is easily missed. Further, since the radiative forcing is a result of BC distributed through the entire atmospheric column, aircraft sampling is by definition incomplete. We are in the process of planning a more comprehensive sampling of the atmosphere for BC using high-altitude balloons. Balloon-borne sampling is a highly reliable means to sample air through the entire troposphere and into the lower stratosphere. Our system will incorporate a balloon and a flight train of two modules. One module will house an atmospheric sampler. This sampler will be single-stage (samples all particle sizes together), and will place particles directly on an SEM sample stub for analysis. The nozzle depositing the sample will be offset from the center of the stub, placing the aerosol particles toward the edge. At various altitudes, the stub will be rotated 45 degrees, providing 6-8 sample “cuts” of particle populations through the atmospheric column. The flights will reach approximately 27 km altitude, above which the balloons

  3. Non-linear analysis and the design of Pumpkin Balloons: stress, stability and viscoelasticity

    Science.gov (United States)

    Rand, J. L.; Wakefield, D. S.

    Tensys have a long-established background in the shape generation and load analysis of architectural stressed membrane structures Founded upon their inTENS finite element analysis suite these activities have broadened to encompass lighter than air structures such as aerostats hybrid air-vehicles and stratospheric balloons Winzen Engineering couple many years of practical balloon design and fabrication experience with both academic and practical knowledge of the characterisation of the non-linear viscoelastic response of the polymeric films typically used for high-altitude scientific balloons Both companies have provided consulting services to the NASA Ultra Long Duration Balloon ULDB Program Early implementations of pumpkin balloons have shown problems of geometric instability characterised by improper deployment and these difficulties have been reproduced numerically using inTENS The solution lies in both the shapes of the membrane lobes and also the need to generate a biaxial stress field in order to mobilise in-plane shear stiffness Balloons undergo significant temperature and pressure variations in flight The different thermal characteristics between tendons and film can lead to significant meridional stress Fabrication tolerances can lead to significant local hoop stress concentrations particularly adjacent to the base and apex end fittings The non-linear viscoelastic response of the envelope film acts positively to help dissipate stress concentrations However creep over time may produce lobe geometry variations that may

  4. Intravascular Ultrasound Imaging of Peripheral Arteries as an Adjunct to Balloon Angioplasty and Atherectomy

    International Nuclear Information System (INIS)

    Korogi, Yukunori; Hirai, Toshinori; Takahashi, Mutsumasa

    1996-01-01

    This article reviews many of the applications of intravascular ultrasound (US) imaging for peripheral arterial diseases. In vitro studies demonstrate an excellent correlation between ultrasound measurements of lumen and plaque crossectional area compared with histologic sections. In vivo clinical studies reveal the enhanced diagnostic capabilities of this technology compared with angiography. Intravascular US imaging can provide valuable information on the degree, eccentricity, and histologic type of stenosis before intervention, and on the morphological changes in the arterial wall and the extent of excision after intervention. Intravascular US may also serve as a superior index for gauging the diameter of balloon, stent, laser probe, and/or atherectomy catheter appropriate for a proposed intervention. Significant new insights into the mechanisms of balloon angioplasty and atherectomy have been established by intravascular US findings. Intravascular US imaging has been shown to be a more accurate method than angiography for determining the cross-sectional area of the arterial lumen, and for assessing severity of stenosis. Quantitative assessment of the luminal cross-sectional area after the balloon dilatation should be more accurate than angiography as intimal tears or dissections produced by the dilatation may not be accurately evaluated with angiography. At the present time, intravascular US is still a controversial imaging technique. Outcome studies are currently being organized to assess the clinical value and cost effectiveness of intravascular ultrasound in the context of these interventional procedures

  5. Taksterfte in Buxus, veroorzaakt door Cylindrocladium buxicola

    NARCIS (Netherlands)

    Kuik, van A.J.; Dalfsen, van P.

    2010-01-01

    De laatste jaren wordt de Buxusteelt geplaagd door een ziekte die veroorzaakt wordt door de schimmel Cylindrocladium buxicola. Gezien de snelle uitbreiding van de ziekte is het voor kwekers en afnemers van Buxus van groot belang dat deze problematiek wordt aangepakt. Daar om is begin 2006 in

  6. Heat Transfer Model for Hot Air Balloons

    OpenAIRE

    Lladó Gambín, Adriana

    2016-01-01

    A heat transfer model and analysis for hot air balloons is presented in this work, backed with a flow simulation using SolidWorks. The objective is to understand the major heat losses in the balloon and to identify the parameters that affect most its flight performance. Results show that more than 70% of the heat losses are due to the emitted radiation from the balloon envelope and that convection losses represent around 20% of the total. A simulated heating source is also included in the mod...

  7. Time-to-reperfusion in STEMI undergoing interhospital transfer using smartphone and WhatsApp messenger.

    Science.gov (United States)

    Astarcioglu, Mehmet Ali; Sen, Taner; Kilit, Celal; Durmus, Halil Ibrahim; Gozubuyuk, Gokhan; Kalcik, Macit; Karakoyun, Suleyman; Yesin, Mahmut; Zencirkiran Agus, Hicaz; Amasyali, Basri

    2015-10-01

    The objective of this study is to assess the efficacy of WhatsApp application as a communication method among the emergency physician (EP) in a rural hospital without percutaneous coronary intervention (PCI) capability and the interventional cardiologist at a tertiary PCI center. Current guidelines recommend that patients with ST-segment elevation myocardial infarction (STEMI) receive primary PCI within 90 minutes. This door-to-balloon (D2B) time has been difficult to achieve in rural STEMI. We evaluated 108 patients with STEMI in a rural hospital with emergency department but without PCI capability to determine the impact of WhatsApp triage and activation of the cardiac catheterization laboratory on D2B time. The images were obtained from cases of suspected STEMI using the smartphones by the EP and were sent to the interventional cardiologist via the WhatsApp application (group 1, n=53). The control group included concurrently treated patients with STEMI during the same period but not receiving triage (group 2, n=55). The D2B time was significantly shorter in the intervention group (109±31 vs 130±46 minutes, PWhatsApp triage with activation of the cardiac catheterization laboratory was associated with shorter D2B time and results in a greater proportion of patients achieving guideline recommendations. The method is cheap, quick, and easy to operate. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. A Study on the Modeling of the Oil Damper in an Auto-Door Hinge

    International Nuclear Information System (INIS)

    Ha, Kwang Soon; Kim, Jong Tae; Kim, Hwan Yeol

    2009-11-01

    An auto-door hinge, which is one of the automatic door-closing apparatuses, has been widely used to prevent fire propagations in living or commercial buildings. The auto-door hinge consists of a spring to accumulate power for closing a door and an oil damper to control door-closing velocity. To predict and optimize the temporal door behavior during the door-closing period, the auto-door closing system was modeled as a second order-damping system. And a damping coefficient of the oil damper was also theoretically modeled by analyzing Newtonian, incompressible, viscous flow through an oil passage between a oil control rod and a oil piston body. The temporal door behaviors during the door-closing period were predicted with respect to the gap distance of the oil passage, oil viscosity, and pre-compressing of the spring. Temporal door behavior measurement method using an encoder system was also developed to validate the modelling on the oil damping system. As using the developed test apparatus, the temporal door position, velocity, and rotational torque were measured, and the modelling method was evaluated

  9. A Study on the Modeling of the Oil Damper in an Auto-Door Hinge

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Kwang Soon; Kim, Jong Tae; Kim, Hwan Yeol

    2009-11-15

    An auto-door hinge, which is one of the automatic door-closing apparatuses, has been widely used to prevent fire propagations in living or commercial buildings. The auto-door hinge consists of a spring to accumulate power for closing a door and an oil damper to control door-closing velocity. To predict and optimize the temporal door behavior during the door-closing period, the auto-door closing system was modeled as a second order-damping system. And a damping coefficient of the oil damper was also theoretically modeled by analyzing Newtonian, incompressible, viscous flow through an oil passage between a oil control rod and a oil piston body. The temporal door behaviors during the door-closing period were predicted with respect to the gap distance of the oil passage, oil viscosity, and pre-compressing of the spring. Temporal door behavior measurement method using an encoder system was also developed to validate the modelling on the oil damping system. As using the developed test apparatus, the temporal door position, velocity, and rotational torque were measured, and the modelling method was evaluated.

  10. Structure variations of pumpkin balloon

    Science.gov (United States)

    Yajima, N.; Izutsu, N.; Honda, H.

    2004-01-01

    A lobed pumpkin balloon by 3-D gore design concept is recognized as a basic form for a super-pressure balloon. This paper deals with extensions of this design concept for other large pressurized membrane structures, such as a stratospheric airship and a balloon of which volume is controllable. The structural modifications are performed by means of additional ropes, belts or a strut. When the original pumpkin shape is modified by these systems, the superior characteristics of the 3-D gore design, incorporating large bulges with a small local radius and unidirectional film tension, should be maintained. Improved design methods which are adequate for the above subjects will be discussed in detail. Application for ground structures are also mentioned.

  11. Continuous quality improvement process pin-points delays, speeds STEMI patients to life-saving treatment.

    Science.gov (United States)

    2011-11-01

    Using a multidisciplinary team approach, the University of California, San Diego, Health System has been able to significantly reduce average door-to-balloon angioplasty times for patients with the most severe form of heart attacks, beating national recommendations by more than a third. The multidisciplinary team meets monthly to review all cases involving patients with ST-segment-elevation myocardial infarctions (STEMI) to see where process improvements can be made. Using this continuous quality improvement (CQI) process, the health system has reduced average door-to-balloon times from 120 minutes to less than 60 minutes, and administrators are now aiming for further progress. Among the improvements instituted by the multidisciplinary team are the implementation of a "greeter" with enough clinical expertise to quickly pick up on potential STEMI heart attacks as soon as patients walk into the ED, and the purchase of an electrocardiogram (EKG) machine so that evaluations can be done in the triage area. ED staff have prepared "STEMI" packets, including items such as special IV tubing and disposable leads, so that patients headed for the catheterization laboratory are prepared to undergo the procedure soon after arrival. All the clocks and devices used in the ED are synchronized so that analysts can later review how long it took to complete each step of the care process. Points of delay can then be targeted for improvement.

  12. Inflatable door seals - reduced maintenance and longer service-life

    International Nuclear Information System (INIS)

    Kuran, S.; Wensel, R.; Lazic, M.

    1995-01-01

    Inflatable door seals, designed more than a quarter of a century ago, have given good service in Canadian and overseas CANDU reactors. These thin-walled elastomeric seals have been exposed to many thousands of cycles of inflation and deflation, various types of aging (temperature, radiation and time), ozone degradation, abrasion, pinching, stiction, cracking and installation damage. The fact that they have operated successfully as part of the reactor building containment structure - subjected to the same pressures and temperatures as those for the thick reinforced concrete walls and steel doors highlights the achievement of these thin rubber seals. However, in the last decade, the rubber industry has developed new compounds that are more resistant to radiation, temperature, and time-dependent aging. Components manufactured from such compounds are less prone to hardening, stress cracking and permanent set; thereby saving on replacement costs, inventory and overall maintenance. This paper discusses development and testing of recent material and design changes to inflatable seals, and addresses various practical issues faced by the operations engineers and maintainers using these seals. (author)

  13. Accurate Determination of the Volume of an Irregular Helium Balloon

    Science.gov (United States)

    Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine

    2013-01-01

    In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…

  14. A tethered balloon system for observation of atmospheric temperature inversion

    International Nuclear Information System (INIS)

    Hayashi, Takashi; Kakuta, Michio

    1979-05-01

    In environmental assessment of near-shore nuclear plants, information is often required on the development of internal boundary layer (IBL) and associated fumigation condition. Single tower data is not sufficient to clarify the site-dependent IBL structure that affects the atmospheric diffusion in shoreline-stack-site boundary complex. A tethered balloon system has been developed, which comprises a fixed point kitoon and a car-borne small balloon. The system enables us to measure the detailed time-space distribution of temperature without much man-power. The system and example of field observations with it are described. (author)

  15. Analysis of Flight of Near-Space Balloon

    Science.gov (United States)

    Miller, Zech; Evans, Austin; Seyfert, James; Leadlove, Kyle; Gumina, Kaitlyn; Martell, Eric

    2015-04-01

    In December 2014, the Electronics class at Millikin University launched a balloon designed to travel into the near-space region of the atmosphere. The balloon was equipped with an instrumentation package including a camera, accelerometer, barometric pressure sensor, temperature probes, as well as a system for tracking using an Automatic Packet Reporting System (APRS). The balloon was launched from Decatur, IL, and landed in Marysville, OH, nearly 320 miles away. The students then analyzed the data from the flight and compared results to expectations.

  16. Safety and effectiveness of gastric balloons associated with hypocaloric diet for the treatment of obesity

    Directory of Open Access Journals (Sweden)

    M.ª Luisa de Castro

    2013-10-01

    Full Text Available Introduction: intragastric balloons provide early satiety and thereby induce short-term weight loss. The aim of this study was to evaluate safety and short and medium-term effectiveness of gastric balloons associated to hypocaloric diet in obesity. Material and methods: from May 2004 to June 2011 91 obese patients, body mass index [BMI] 45.2 ± 7.2 kg/m² were prospectively followed after endoscopic implantation of a gastric balloon associated to restricted diet. Successful therapy was defined as percent loss of total weight (%LTW ≥ 5% at six months after balloon placement and 6 and 12 months after their withdrawal. All analyses followed intention-to treat principles considering significant p-values < 0.05. Results: we placed 73 fluid-filled balloons (80.2% and 18 air-filled ones (19.8%. Compared to baseline values, at 6-month 73.7% subjects succeeded, showing significant reductions in weight (13.3 ± 8.8 kg, BMI (5 ± 3.4 kg/m² (p < 0.0001, with% LTW 11 ± 7%. Six and twelve months after retrieval 45.1% and 28.6% patients reached% LTW ≥ 5%. Short-term and medium-term effectiveness was negatively associated to obesity in first-grade relatives (p = 0.003 and p = 0.04. Higher weight loss 6 months after balloon placement independently predicted medium-term effectiveness (p = 0.0001. Mortality was absent but there were two spontaneous deflations of air-filled balloons and severe withdrawal difficulties in 8 patients, leading to surgery in one case. Retrieval complications associated to air-filled balloons (p = 0.0005. Conclusions: in obesity, effectiveness of gastric balloons associated to hypocaloric diet decreases over time. Complications occurred mainly in the retrieval endoscopic procedure and related to air-filled balloons.

  17. Components for containment enclosures - Part 3: Transfer systems such as plain doors, airlock chambers, double door transfer systems, leaktight connections for waste drums. 1. ed.

    International Nuclear Information System (INIS)

    1998-01-01

    This part of ISO 11933 specifies requirements for the selection, construction and use of the following leak tight components: doors, airlock chambers, double door transfer systems, leaktight connections for waste drums. Some of the elements, double doors or airlock chambers are described in ISO 11933-1 and ISO 11933-2 as well. Doors having bigger dimensions used for personnel od larger objects are not covered by this document

  18. Benefits of Balloon-Dilatable Bilateral Pulmonary Artery Banding in Patients With Hypoplastic Left Heart Syndrome and Other Complex Cardiac Anomalies.

    Science.gov (United States)

    Kise, Hiroaki; Suzuki, Shoji; Hoshiai, Minako; Toda, Takako; Koizumi, Keiichi; Hasebe, Yohei; Kono, Yosuke; Honda, Yoshihiro; Kaga, Shigeaki; Sugita, Kanji

    2015-12-01

    The purpose of this study was to evaluate the potential of balloon-dilatable bilateral pulmonary artery banding (b-PAB) and its impact on the configuration of the pulmonary artery (PA). We have previously used balloon-dilatable b-PAB as first-stage palliation for patients with hypoplastic left heart syndrome (HLHS) and other complex cardiac anomalies. Two pliable tapes were placed around each branch of the PA and tightened with 7-0 polypropylene sutures in a manner that allowed for the subsequent adjustment of PA diameters. We retrospectively examined the adjustability of PA diameters by balloon dilation and the need for surgical PA angioplasty at later stages. From January 2010 to October 2013, we performed b-PAB in 8 patients, including 3 borderline cases between biventricular repair (BVR) and univentricular repair (UVR). The b-PAB procedures were performed at a median age of 6.5 days (range, 2-10 days). Balloon dilations were performed in 10 lesions in 4 patients. All of the procedures were performed safely. Two patients reached definite BVR. The remaining 6 patients underwent open palliative procedures with univentricular physiologies that resulted in 2 deaths unrelated to the initial b-PAB. In all but 1 of the patients, the PA configuration was properly maintained and did not require surgical pulmonary angioplasty. Balloon-dilatable b-PAB can be performed safely and prevents PA distortion at later stages. This technique should be considered for patients with complex cardiac anomalies if uncertainty exists regarding the optimal surgical strategy (BVR or UVR) in early infancy. © 2015, Wiley Periodicals, Inc.

  19. Introduction (Special Issue on Scientific Balloon Capabilities and Instrumentation)

    Science.gov (United States)

    Gaskin, Jessica A.; Smith, I. S.; Jones, W. V.

    2014-01-01

    In 1783, the Montgolfier brothers ushered in a new era of transportation and exploration when they used hot air to drive an un-tethered balloon to an altitude of 2 km. Made of sackcloth and held together with cords, this balloon challenged the way we thought about human travel, and it has since evolved into a robust platform for performing novel science and testing new technologies. Today, high-altitude balloons regularly reach altitudes of 40 km, and they can support payloads that weigh more than 3,000 kg. Long-duration balloons can currently support mission durations lasting 55 days, and developing balloon technologies (i.e. Super-Pressure Balloons) are expected to extend that duration to 100 days or longer; competing with satellite payloads. This relatively inexpensive platform supports a broad range of science payloads, spanning multiple disciplines (astrophysics, heliophysics, planetary and earth science.) Applications extending beyond traditional science include testing new technologies for eventual space-based application and stratospheric airships for planetary applications.

  20. Deflation of gastric band balloon in pregnancy for improving outcomes.

    Science.gov (United States)

    Jefferys, Amanda E; Siassakos, Dimitrios; Draycott, Tim; Akande, Valentine A; Fox, Robert

    2013-04-30

    In line with the rise in the prevalence of obesity, an increasing number of women of childbearing age are undergoing laparoscopic adjustable gastric banding (LAGB), resulting in an increasing number of pregnancies with a band in place. Currently, there is no consensus on optimal band management in pregnancy. Some clinicians advocate leaving the band balloon inflated to reduce gestational weight gain and associated adverse perinatal outcomes. However, there are concerns that maintaining balloon inflation during pregnancy might increase the risk of band complications and adversely affect fetal development and/or growth as a result of reduced nutritional intake. To compare maternal and perinatal outcomes for elective gastric band balloon deflation versus intention to maintain balloon inflation during pregnancy. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 September 2012) and the Web of Science database (1940 to September 2012). Randomised-controlled trials comparing elective deflation of the gastric band balloon with intention to maintain balloon inflation in pregnant women who have undergone LAGB. Two review authors independently assessed studies for inclusion. No studies met the criteria for inclusion in the review. To date no randomised controlled trials exist that compare elective deflation of the gastric band balloon in pregnancy versus intention to maintain balloon inflation. Further research is needed to define the optimum management of the gastric band balloon in pregnancy.

  1. Cryo-balloon catheter localization in fluoroscopic images

    Science.gov (United States)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  2. Median Survival Time of Endometrial Cancer Patients with Lymphovascular Invasion at the Hospital Universiti Sains Malaysia.

    Science.gov (United States)

    Asyikeen, Wan Adnan Wan Nor; Siti-Azrin, Ab Hamid; Jalil, Nur Asyilla Che; Zin, Anani Aila Mat; Othman, Nor Hayati

    2016-11-01

    Endometrial cancer is the most common gynaecologic malignancy among females worldwide. The purpose of this study was to determine the median survival time of endometrial cancer patients at the Hospital Universiti Sains Malaysia (USM). A list of 121 endometrial cancer cases registered at Hospital USM between 2000 until 2011 was retrospectively reviewed. The survival time of the endometrial cancer patients was estimated by Kaplan-Meier survival analysis. Log-rank tests were performed to compare the survival of the patients based on socio-demographics and clinical presentation. Only 108 patients, 87.0%, were included who were of Malay ethnicity. Previous history included menopause in 67.6% of patients and diabetes mellitus in 39.8% of patients; additionally, 63.4% of patients were nulliparous. Tumour staging was as follows: 24.5% stage I, 10.8% stage II, 26.5% stage III and 38.2% stage IV. The overall median survival time of the endometrial cancer patients was 70.20 months (95% confidence interval (CI): 51.79, 88.61). The significant factors were age, the presence of lymphovascular invasion and treatment received. The overall survival of endometrial cancer was low. A prospective study needs to be carried out to discover more effective and accurate tests for the early detection of endometrial cancer.

  3. Reduction of prostate intrafraction motion using gas-release rectal balloons

    International Nuclear Information System (INIS)

    Su Zhong; Zhao Tianyu; Li Zuofeng; Hoppe, Brad; Henderson, Randy; Mendenhall, William; Nichols, R. Charles; Marcus, Robert; Mendenhall, Nancy

    2012-01-01

    Purpose: To analyze prostate intrafraction motion using both non-gas-release (NGR) and gas-release (GR) rectal balloons and to evaluate the ability of GR rectal balloons to reduce prostate intrafraction motion. Methods: Twenty-nine patients with NGR rectal balloons and 29 patients with GR balloons were randomly selected from prostate patients treated with proton therapy at University of Florida Proton Therapy Institute (Jacksonville, FL). Their pretreatment and post-treatment orthogonal radiographs were analyzed, and both pretreatment setup residual error and intrafraction-motion data were obtained. Population histograms of intrafraction motion were plotted for both types of balloons. Population planning target-volume (PTV) margins were calculated with the van Herk formula of 2.5Σ+ 0.7σ to account for setup residual errors and intrafraction motion errors. Results: Pretreatment and post-treatment radiographs indicated that the use of gas-release rectal balloons reduced prostate intrafraction motion along superior–inferior (SI) and anterior–posterior (AP) directions. Similar patient setup residual errors were exhibited for both types of balloons. Gas-release rectal balloons resulted in PTV margin reductions from 3.9 to 2.8 mm in the SI direction, 3.1 to 1.8 mm in the AP direction, and an increase from 1.9 to 2.1 mm in the left–right direction. Conclusions: Prostate intrafraction motion is an important uncertainty source in radiotherapy after image-guided patient setup with online corrections. Compared to non-gas-release rectal balloons, gas-release balloons can reduce prostate intrafraction motion in the SI and AP directions caused by gas buildup.

  4. Reduction of prostate intrafraction motion using gas-release rectal balloons

    Energy Technology Data Exchange (ETDEWEB)

    Su Zhong; Zhao Tianyu; Li Zuofeng; Hoppe, Brad; Henderson, Randy; Mendenhall, William; Nichols, R. Charles; Marcus, Robert; Mendenhall, Nancy [Department of Radiation Oncology, University of Florida Proton Therapy Institute, Jacksonville, Florida 32206 (United States)

    2012-10-15

    Purpose: To analyze prostate intrafraction motion using both non-gas-release (NGR) and gas-release (GR) rectal balloons and to evaluate the ability of GR rectal balloons to reduce prostate intrafraction motion. Methods: Twenty-nine patients with NGR rectal balloons and 29 patients with GR balloons were randomly selected from prostate patients treated with proton therapy at University of Florida Proton Therapy Institute (Jacksonville, FL). Their pretreatment and post-treatment orthogonal radiographs were analyzed, and both pretreatment setup residual error and intrafraction-motion data were obtained. Population histograms of intrafraction motion were plotted for both types of balloons. Population planning target-volume (PTV) margins were calculated with the van Herk formula of 2.5{Sigma}+ 0.7{sigma} to account for setup residual errors and intrafraction motion errors. Results: Pretreatment and post-treatment radiographs indicated that the use of gas-release rectal balloons reduced prostate intrafraction motion along superior-inferior (SI) and anterior-posterior (AP) directions. Similar patient setup residual errors were exhibited for both types of balloons. Gas-release rectal balloons resulted in PTV margin reductions from 3.9 to 2.8 mm in the SI direction, 3.1 to 1.8 mm in the AP direction, and an increase from 1.9 to 2.1 mm in the left-right direction. Conclusions: Prostate intrafraction motion is an important uncertainty source in radiotherapy after image-guided patient setup with online corrections. Compared to non-gas-release rectal balloons, gas-release balloons can reduce prostate intrafraction motion in the SI and AP directions caused by gas buildup.

  5. Modular and Reusable Power System Design for the BRRISON Balloon Telescope

    Science.gov (United States)

    Truesdale, Nicholas A.

    High altitude balloons are emerging as low-cost alternatives to orbital satellites in the field of telescopic observation. The near-space environment of balloons allows optics to perform near their diffraction limit. In practice, this implies that a telescope similar to the Hubble Space Telescope could be flown for a cost of tens of millions as opposed to billions. While highly feasible, the design of a balloon telescope to rival Hubble is limited by funding. Until a prototype is proven and more support for balloon science is gained, projects remain limited in both hardware costs and man hours. Thus, to effectively create and support balloon payloads, engineering designs must be efficient, modular, and if possible reusable. This thesis focuses specifically on a modular power system design for the BRRISON comet-observing balloon telescope. Time- and cost-saving techniques are developed that can be used for future missions. A modular design process is achieved through the development of individual circuit elements that span a wide range of capabilities. Circuits for power conversion, switching and sensing are designed to be combined in any configuration. These include DC-DC regulators, MOSFET drivers for switching, isolated switches, current sensors and voltage sensing ADCs. Emphasis is also given to commercially available hardware. Pre-fabricated DC-DC converters and an Arduino microcontroller simplify the design process and offer proven, cost-effective performance. The design of the BRRISON power system is developed from these low-level circuits elements. A board for main power distribution supports the majority of flight electronics, and is extensible to additional hardware in future applications. An ATX computer power supply is developed, allowing the use of a commercial ATX motherboard as the flight computer. The addition of new capabilities is explored in the form of a heater control board. Finally, the power system as a whole is described, and its overall

  6. Proceedings (Supplement), AFCRL Scientific Balloon Symposium (8th) 30 September to 3 October 1974

    Science.gov (United States)

    1974-12-02

    Air Force Cambrldge Research Laboratorles, AFCR L-TR -73-0447. 55 I Session 2 Tethered Balloons Rded. Cpap lCainm-m TCOu Cotpaeutin Precediug page blank...interesting case. (See Figure 13). The balloon, flying at about 4, 000 feet, was struck by a flash from a cloud which we believe was about five miles away...where lighting is probable. The significant factors here are that a balloon with a poorly conducting tether was struck from a flash from a relatively

  7. The chatter door, designing for in-between spaces

    NARCIS (Netherlands)

    Duel, T.; Levy, P.

    2015-01-01

    The project presented in this paper is part of a broader research addressing in-between spaces and the designing of experiences taking place there. The project focuses on door frames, and inquires the way to improve social interactions taking place 'at the door'. To do so, the approach is structured

  8. Bunker door interlock limit issues of K-130 cyclotron, VECC

    International Nuclear Information System (INIS)

    Srihari, K.; Ravishankar, R.; Mitra, M.S.; Mishra, S.K.; Bandyopadhyay, T.; Sarkar, P.K.

    2011-01-01

    The K-130 cyclotron is in operation at VECC, Kolkata. Recently modernization of the cyclotron has taken place. Central region modification has increased reasonable internal beam current. During the tuning of the projectiles, loss of beam is unavoidable and projectiles hitting different parts of the machine inside the vacuum chamber . These interactions produce prompt radiation comprising neutron and gamma. However machine bunker is not accessible during the operation of the machine. The induced activity produced because of interactions of the primary and secondary radiation a radiation hazardous environment during the shut down for the related maintenance work. Area radiation monitors placed at machine bunker room have the interlock with massive shield door of the bunker. Area radiation monitors are set to specified limiting value, lower than that will allow to open the shield door in normal condition. As, the internal beam current being increased and the probability of beam spread being more. Consequently generation of induced activity is also high leading to delay in machine bunker door opening because of the interlock settings. Radiation dose mapping after a long operation of the machine was done for the different strategic points (The locations mainly people access immediate after shut down). Different consequences and remedial measures being presented in paper to raise the dose rate limit level for the interlocks between the area radiation monitors with machine bunker door, keeping in mind of the regulatory requirements. Raising the limit of dose rate limiting value will minimize the waiting time to access the machine bunker which will increase the duty factor of the machine. (author)

  9. Taking the Hot Air Out of Balloons.

    Science.gov (United States)

    Brinks, Virgil L.; Brinks, Robyn L.

    1994-01-01

    Describes how a teacher can give their students the challenge of designing and building model balloons or blimps. The project helps students learn the basics of balloon flight and what it really means to be "lighter than air." (PR)

  10. Balloon catheter dilation of benign esophageal stenosis in children

    International Nuclear Information System (INIS)

    Fan Guoping; Yu Juming; Zhong Weixing; Zhu Ming; Wu Yeming; Shi Chengren

    2001-01-01

    Objective: To evaluate the methods and effect of balloon catheter dilation of benign esophageal stenosis in children. Methods: 9 cases had an anastomotic stenosis after surgical correction of esophageal atresia; 11 cases of esophageal stenosis due to ingestion of caustics; one case had an lower esophageal stenosis after Nissen surgery and one case after gastro-esophagoplasty. Age ranged from 17 days to 7 years. Each case had a barium esophagram before balloon dilation. The balloon size varied from 3 to 10 mm in diameter. Results: 21 cases were successful after dilation of balloon catheter. There were no esophageal perforation and complications. The satisfactory results maintained from six months to thirty months. Conclusions: Balloon catheter dilation is a simple, safe and reliable method for the treatment of benign esophageal strictures in children as the first choice

  11. Ballooning modes or Fourier modes in a toroidal plasma?

    International Nuclear Information System (INIS)

    Connor, J.W.; Taylor, J.B.

    1987-01-01

    The relationship between two different descriptions of eigenmodes in a torus is investigated. In one the eigenmodes are similar to Fourier modes in a cylinder and are highly localized near a particular rational surface. In the other they are the so-called ballooning modes that extend over many rational surfaces. Using a model that represents both drift waves and resistive interchanges the transition from one of these structures to the other is investigated. In this simplified model the transition depends on a single parameter which embodies the competition between toroidal coupling of Fourier modes (which enhances ballooning) and variation in frequency of Fourier modes from one rational surface to another (which diminishes ballooning). As the coupling is increased each Fourier mode acquires a sideband on an adjacent rational surface and these sidebands then expand across the radius to form the extended mode described by the conventional ballooning mode approximation. This analysis shows that the ballooning approximation is appropriate for drift waves in a tokamak but not for resistive interchanges in a pinch. In the latter the conventional ballooning effect is negligible but they may nevertheless show a ballooning feature. This is localized near the same rational surface as the primary Fourier mode and so does not lead to a radially extended structure

  12. Paraplegia following intraaortic balloon circulatory assistance

    Directory of Open Access Journals (Sweden)

    Benício Anderson

    1999-01-01

    Full Text Available Intraaortic balloon counterpulsation is frequently used in patients experiencing severe ventricular dysfunction following maximal drug therapy. However, even with the improvement of percutaneous insertion techniques, the procedure has always been followed by vascular, infectious, and neurological complications. This article describes a case of paraplegia due to intraaortic balloon counterpulsation in the postoperative period of cardiac surgery.

  13. Psychiatric wards with locked doors--advantages and disadvantages according to nurses and mental health nurse assistants.

    Science.gov (United States)

    Haglund, K; von Knorring, L; von Essen, L

    2006-04-01

    To describe nurses' and mental health nurse assistants' perceptions of advantages and disadvantages about working on a psychiatric ward with a locked entrance door. Psychiatric staff sometimes needs to protect patients from harming themselves or others. To keep the entrance door locked may help staff to achieve this goal. How locked entrance doors at psychiatric wards are experienced by staff, working on these wards, has been investigated to a very limited extent. The study was explorative and descriptive. Audio taped, semi-structured interviews with open-ended questions about advantages and disadvantages about working on a psychiatric ward with a locked entrance door, were conducted with 20 nurses and 20 mental health nurse assistants. Data were analyzed with content analysis. A content analysis revealed eight categories of advantages and 18 categories of disadvantages. Most advantages mentioned by nurses and mental health nurse assistants were categorized as providing staff with control over patients, providing patients with a secure and efficient care and protecting patients and staff against 'the outside'. Most disadvantages mentioned by nurses were categorized as causing extra work for staff, making patients feel confined, making patients feel dependent and creating a non-caring environment. Most disadvantages mentioned by mental health nurse assistants were categorized as causing extra work for staff, making patients feel confined, causing emotional problems for patients, making staff's power obvious and forcing patients to adapt to other patients' needs. Nurses and mental health nurse assistants mentioned more disadvantages than advantages and nurses mentioned more disadvantages than mental health nurse assistants. Nurses and mental health nurse assistants perceive a number of advantages and disadvantages for themselves, patients and significant others with a locked door at a psychiatric ward. Most of these concern patients' experiences. It is important for

  14. [Balloon cell nevi of the conjunctiva (author's transl)].

    Science.gov (United States)

    Schlageter, P E; Daicker, B

    1975-06-01

    The clinical and histological features of three cases of conjunctival balloon cell nevi are described. This peculiar form of nevus is very rare in the conjunctiva. The findings are compared with the descriptions in the literature of dermal balloon cell nevi. They demonstrate, that the conjunctival and dermal tumours are of idential histological structure. The proliferations of the conjunctival epithelium often found in conjunctival nevi do not modify the balloon cell nevi. These can not be diagnosed clinically. The problems of the pathogenesis of the balloon cell nevi are discussed.

  15. Door locking and exit security measures on acute psychiatric admission wards

    NARCIS (Netherlands)

    Nijman, H.L.I.; Bowers, L.; Haglund, K.; Muir-Cochrane, E.; Simpson, A.; Merwe, M. van der

    2011-01-01

    Locking the exit doors of psychiatric wards is believed to reduce the risk of patients absconding. The aims of the study were to investigate both the prevalence of door locking and other exit security measures on UK admission wards, as well as whether door locking appears to be effective in keeping

  16. Special sliding door with storable handrail to support senior and handicapped persons to walk by themselves

    Science.gov (United States)

    Saitou, K.; Noda, N.-A.; Sano, Y.; Takase, Y.; Murai, K.; Wang, Z. F.; Li, S. Q.; Liu, X.; Tanaka, H.; Kubo, Y.

    2018-06-01

    In this paper, special sliding door is designed in order to support senior and handicapped persons to walk by themselves in hospitals and nursing facilities. This semiautomatic lifting equipment is utilized for the storable handrail to make sure the bad health persons are able to open the door by using a weak force. In this study, to design the equipment of the handrail, the theoretical formula of opening force is derived. Then the simulation is performed by varying geometrical conditions. The simulation results are compared with the experiment results.

  17. Lifting options for stratospheric aerosol geoengineering: advantages of tethered balloon systems.

    Science.gov (United States)

    Davidson, Peter; Burgoyne, Chris; Hunt, Hugh; Causier, Matt

    2012-09-13

    The Royal Society report 'Geoengineering the Climate' identified solar radiation management using albedo-enhancing aerosols injected into the stratosphere as the most affordable and effective option for geoengineering, but did not consider in any detail the options for delivery. This paper provides outline engineering analyses of the options, both for batch-delivery processes, following up on previous work for artillery shells, missiles, aircraft and free-flying balloons, as well as a more lengthy analysis of continuous-delivery systems that require a pipe connected to the ground and supported at a height of 20 km, either by a tower or by a tethered balloon. Towers are shown not to be practical, but a tethered balloon delivery system, with high-pressure pumping, appears to have much lower operating and capital costs than all other delivery options. Instead of transporting sulphuric acid mist precursors, such a system could also be used to transport slurries of high refractive index particles such as coated titanium dioxide. The use of such particles would allow useful experiments on opacity, coagulation and atmospheric chemistry at modest rates so as not to perturb regional or global climatic conditions, thus reducing scale-up risks. Criteria for particle choice are discussed, including the need to minimize or prevent ozone destruction. The paper estimates the time scales and relatively modest costs required if a tethered balloon system were to be introduced in a measured way with testing and development work proceeding over three decades, rather than in an emergency. The manufacture of a tether capable of sustaining the high tensions and internal pressures needed, as well as strong winds, is a significant challenge, as is the development of the necessary pumping and dispersion technologies. The greatest challenge may be the manufacture and launch of very large balloons, but means have been identified to significantly reduce the size of such balloons or aerostats.

  18. An analysis of the deployment of a pumpkin balloon at Mars

    Science.gov (United States)

    Rand, J. L.; Phillips, M. L.

    2004-01-01

    The design of large superpressure balloons has received significant attention in recent years due to the successful demonstration of various enabling technologies and materials. Of particular note is the "pumpkin" shaped balloon concept, which allows the stress in the envelope to be limited by the surface geometry. Unlike a sphere, where the radius used to determine the stress is determined by the volume of the balloon, the pumpkin utilizes a system of meridional tendons to react the loading in one direction, and form a number of lobes, which limit the stress in the circumferential direction. A suitable superpressure balloon has been designed using this technology which will carry 2 kg in the atmosphere of Mars. The deployment of this balloon is assumed to occur while falling on a decelerator suitably designed for the Mars atmosphere. The inflation is accomplished by a 10 kg system suspended at the nadir of the balloon. As the system falls toward the surface of the planet, helium gas is transferred into the balloon, forming a partially inflated system very similar to an ascending zero pressure balloon. This analysis incorporates the flow of the planetary gas around the inflating balloon which alters the pressure distribution and shape. As a result, stresses are seen to increase beyond the design values which will require the balloon to be redesigned to accommodate this type of dynamic deployment.

  19. Solar Hot Air Balloons: A Low Cost, Multi-hour Flight System for Lightweight Scientific Instrumentation Packages

    Science.gov (United States)

    Bowman, D. C.; Albert, S.; Dexheimer, D.; Murphy, S.; Mullen, M.

    2017-12-01

    Existing scientific ballooning solutions for multi hour flights in the upper troposphere/lower stratosphere are expensive and/or technically challenging. In contrast, solar hot air balloons are inexpensive and simple to construct. These balloons, which rely solely on sunlight striking a darkened envelope, can deliver payloads to 22 km altitude and maintain level flight until sunset. We describe an experimental campaign in which five solar hot air balloons launched in 45 minutes created a free flying infrasound (low frequency sound) microphone network that remained in the air for over 12 hours. We discuss the balloons' trajectory, maximum altitude, and stability as well as present results from the infrasound observations. We assess the performance and limitations of this design for lightweight atmospheric instrumentation deployments that require multi-hour flight times. Finally, we address the possibilities of multi day flights during the polar summer and on other planets.

  20. Assessment of operating room airflow using air particle counts and direct observation of door openings.

    Science.gov (United States)

    Teter, Jonathan; Guajardo, Isabella; Al-Rammah, Tamrah; Rosson, Gedge; Perl, Trish M; Manahan, Michele

    2017-05-01

    The role of the operating room (OR) environment has been thought to contribute to surgical site infection rates. The quality of OR air, disruption of airflow, and other factors may increase contamination risks. We measured air particulate counts (APCs) to determine if they increased in relation to traffic, door opening, and other common activities. During 1 week, we recorded APCs in 5-minute intervals and movement of health care workers. Trained observers recorded information about traffic, door openings, job title of the opener, and the reason for opening. At least 1 OR door was open during 47% of all readings. There were 13.4 door openings per hour during cases. Door opening rates ranged from 0.19-0.28 per minute. During this time, a total of 660 air measurements were obtained. The mean APCs were 9,238 particles (95% confidence interval [CI], 5,494- 12,982) at baseline and 14,292 particles (95% CI, 12,382-16,201) during surgery. Overall APCs increased 13% when either door was opened (P opening. We observed numerous instances of verbal communication and equipment movement. Improving efficiency of communication and equipment can aid in reduction of traffic. Further study is needed to examine links between microbiologic sampling, outcome data, and particulate matter to enable study of risk factors and effects of personnel movement. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  1. New concepts for interplanetary balloons and blimps, particularly for Titan

    Science.gov (United States)

    Nott, J.

    This paper proposes novel approaches for balloons for planets Titan BALLUTE A balloon or blimp arriving at a planet or moon with an atmosphere might inflate falling under a parachute or after landing Neither is ideal In both cases the envelope must include qualities needed for inflation as well as those for flight A ballute BALLoon parachUTE could be used thus a ballute is like a hot air balloon with a large mouth Initially it fills by ram pressure descending through an atmosphere As proposed it would then be heated by solid propellant It would stop descending and float level with hot air lift It is now a perfect location for inflation without wind or movement through the atmosphere and away from the uncertainties of the surface A ballute could be used over several bodies in the solar system BALLOONS FOR LOW TEMPERATURES Flight in very low temperatures is also discussed Conditions are so different that it is useful to examine basic factors These apply for any planet with low temperature and weather calm enough for balloons or blimps First for terrestrial hot air balloons thermal radiation is usually the dominant way heat is lost But radiation rises with the 4th power of absolute temperature At Titan radiation will be one or two orders of magnitude smaller Also the dense atmosphere allows small balloons small temperature differences So convection is small It appears a hot air balloon can easily be heated by a radioactive source likely carried to make electricity Pinholes are not important in such a balloon

  2. Retained intraaortic balloon. Case report and review of the literature.

    Science.gov (United States)

    Grande, A M; Martinelli, L; Graffigna, A; Viganò, M

    1995-01-01

    We report a case of intraaortic balloon entrapment in a 70-year-old man who underwent emergency triple coronary bypass. Intraaortic balloon rupture caused the formation of a clot inside the balloon that eventually was responsible for the balloon's entrapment at the aortic bifurcation. The patient had severe atherosclerosis of the aorta and iliac arteries. Balloon removal required aorto-iliac exposure and aorto-bifemoral bypass. After 16 months, he is symptom free and at home.

  3. Balloon dilatation of iatrogenic urethral strictures

    International Nuclear Information System (INIS)

    Acunas, B.; Acunas, G.; Gokmen, E.; Celik, L.

    1988-01-01

    Balloon dilatation of the urethra was performed in five patients with iatrogenic urethral strictures. The urethral strictures were successfully negotiated and dilated in all patients. Redilatation became necessary in a period ranging from 3 to 10 months. The authors believe that balloon dilatation of the urethra can be safely and successfully performed; the procedure produces minimal trauma and immediate relief of symptoms. (orig.)

  4. Static and quasi-static analysis of lobed-pumpkin balloon

    Science.gov (United States)

    Nakashino, Kyoichi; Sasaki, Makoto; Hashimoto, Satoshi; Saito, Yoshitaka; Izutsu, Naoki

    The present study is motivated by the need to improve design methodology for super pressure balloon with 3D gore design concept, currently being developed at the Scientific Balloon Center of ISAS/JAXA. The distinctive feature of the 3-D gore design is that the balloon film has excess materials not only in the circumferential direction but also in the meridional direction; the meridional excess is gained by attaching the film boundaries to the corresponding tendons of a shorter length with a controlled shortening rate. The resulting balloon shape is a pumpkin-like shape with large bulges formed between adjacent tendons. The balloon film, when fully inflated, develops wrinkles in the circumferential direction over its entire region, so that the stresses in the film are limited to a small amount of uniaxial tension in the circumferential direction while the high meridional loads are carried by re-enforced tendons. Naturally, the amount of wrinkling in the film is dominated by the shortening rate between the film boundaries and the tendon curve. In the 3-D gore design, as a consequence, the shortening rate becomes a fundamental design parameter along with the geometric parameters of the gore. In view of this, we have carried out a series of numerical study of the lobed-pumpkin balloon with varying gore geometry as well as with varying shortening rate. The numerical simula-tions were carried out with a nonlinear finite element code incorporating the wrinkling effect. Numerical results show that there is a threshold value for the shortening rate beyond which the stresses in the balloon film increases disproportionately. We have also carried out quasi-static simulations of the inflation process of the lobed-pumpkin balloon, and have obtained asymmetric deformations when the balloon films are in uniaxial tension state.

  5. Understanding "revolving door" patients in general practice: a qualitative study.

    Science.gov (United States)

    Williamson, Andrea E; Mullen, Kenneth; Wilson, Philip

    2014-02-13

    'Revolving door' patients in general practice are repeatedly removed from general practitioners' (GP) lists. This paper reports a qualitative portion of the first mixed methods study of these marginalised patients. We conducted qualitative semi-structured interviews with six practitioner services staff and six GPs in Scotland, utilizing Charmazian grounded theory to characterise 'revolving door' patients and their impact from professionals' perspectives. 'Revolving door' patients were reported as having three necessary characteristics; they had unreasonable expectations, exhibited inappropriate behaviours and had unmet health needs. A range of boundary breaches were reported too when 'revolving door' patients interacted with NHS staff. We utilise the 'sensitising concepts' of legitimacy by drawing on literature about 'good and bad' patients and 'dirty work designations.' We relate these to the core work of general practice and explore the role that medical and moral schemas have in how health service professionals understand and work with 'revolving door' patients. We suggest this may have wider relevance for the problem doctor patient relationship literature.

  6. Stent-assisted, balloon-induced intimal disruption and relamination of aortic dissection in patients with Marfan syndrome: Midterm outcomes and aortic remodeling.

    Science.gov (United States)

    Faure, Elsa Madeleine; El Batti, Salma; Abou Rjeili, Marwan; Ben Abdallah, Iannis; Julia, Pierre; Alsac, Jean-Marc

    2018-05-17

    The study objective was to assess the midterm outcomes and aortic remodeling in patients with Marfan syndrome with complicated acute type B aortic dissection treated with stent-assisted, balloon-induced intimal disruption and relamination. We reviewed all patients treated with stent-assisted, balloon-induced intimal disruption and relamination for a complicated acute type B aortic dissection associated with Marfan syndrome according to the revised Ghent criteria. Between 2015 and November 2017, 7 patients with Marfan syndrome underwent stent-assisted, balloon-induced intimal disruption and relamination for a complicated acute type B aortic dissection. The median age of patients was 47 years (range, 23-70). Four patients had a history of aortic root replacement. Technical success was achieved in 100%. Three patients required an adjunctive procedure for renal artery stenting (n = 2) and iliac artery stenting (n = 1). There was no in-hospital death, 30-day postoperative stroke, spinal cord ischemia, ischemic colitis, or renal failure requiring dialysis. At a median follow-up of 15 months (range, 7-28), 1 patient required aortic arch replacement for aneurysmal degeneration associated with a type Ia endoleak at 2 years, giving a late reintervention rate of 14%. There was no other secondary endoleak. The primary visceral patency rate was 100%. There were no all-cause deaths reported. At last computed tomography scan, all patients had complete aortic remodeling of the treated thoracoabdominal aorta. Distally, at the nonstented infrarenal aortoiliac level, 6 patients had persistent false lumen flow with stable aorto-iliac diameter in 5. One patient had iliac diameter growth (27 mm diameter at last computed tomography scan). Stent-assisted, balloon-induced intimal disruption and relamination of aortic dissection in patients with Marfan syndrome is feasible, safe, and associated with an immediate and midterm persisting thoracoabdominal aortic remodeling. Copyright

  7. Characterizing the continuously acquired cardiovascular time series during hemodialysis, using median hybrid filter preprocessing noise reduction

    Directory of Open Access Journals (Sweden)

    Wilson S

    2015-01-01

    Full Text Available Scott Wilson,1,2 Andrea Bowyer,3 Stephen B Harrap4 1Department of Renal Medicine, The Alfred Hospital, 2Baker IDI, Melbourne, 3Department of Anaesthesia, Royal Melbourne Hospital, 4University of Melbourne, Parkville, VIC, Australia Abstract: The clinical characterization of cardiovascular dynamics during hemodialysis (HD has important pathophysiological implications in terms of diagnostic, cardiovascular risk assessment, and treatment efficacy perspectives. Currently the diagnosis of significant intradialytic systolic blood pressure (SBP changes among HD patients is imprecise and opportunistic, reliant upon the presence of hypotensive symptoms in conjunction with coincident but isolated noninvasive brachial cuff blood pressure (NIBP readings. Considering hemodynamic variables as a time series makes a continuous recording approach more desirable than intermittent measures; however, in the clinical environment, the data signal is susceptible to corruption due to both impulsive and Gaussian-type noise. Signal preprocessing is an attractive solution to this problem. Prospectively collected continuous noninvasive SBP data over the short-break intradialytic period in ten patients was preprocessed using a novel median hybrid filter (MHF algorithm and compared with 50 time-coincident pairs of intradialytic NIBP measures from routine HD practice. The median hybrid preprocessing technique for continuously acquired cardiovascular data yielded a dynamic regression without significant noise and artifact, suitable for high-level profiling of time-dependent SBP behavior. Signal accuracy is highly comparable with standard NIBP measurement, with the added clinical benefit of dynamic real-time hemodynamic information. Keywords: continuous monitoring, blood pressure

  8. Design and evaluation of a continuum robot with extendable balloons

    Directory of Open Access Journals (Sweden)

    E. Y. Yarbasi

    2018-02-01

    Full Text Available This article presents the design and preliminary evaluation of a novel continuum robot actuated by two extendable balloons. Extendable balloons are utilized as the actuation mechanism of the robot, and they are attached to the tip from their slack sections. These balloons can extend very much in length without having a significant change in diameter. Employing two balloons in an axially extendable, radially rigid flexible shaft, radial strain becomes constricted, allowing high elongation. As inflated, the balloons apply a force on the wall of the tip, pushing it forward. This force enables the robot to move forward. The air is supplied to the balloons by an air compressor and its flow rate to each balloon can be independently controlled. Changing the air volumes differently in each balloon, when they are radially constricted, orients the robot, allowing navigation. Elongation and force generation capabilities and pressure data are measured for different balloons during inflation and deflation. Afterward, the robot is subjected to open field and maze-like environment navigation tests. The contribution of this study is the introduction of a novel actuation mechanism for soft robots to have extreme elongation (2000 % in order to be navigated in substantially long and narrow environments.

  9. Balloon dilatation of nasopharyngeal stenosis in a dog.

    Science.gov (United States)

    Berent, Allyson C; Kinns, Jennifer; Weisse, Chick

    2006-08-01

    A dog was examined because of a 6-month history of upper airway stridor that began after postoperative regurgitation of gastric contents. Constant stridor was evident during inspiration and expiration, although it was worse during inspiration. The stridor was no longer evident when the dog's mouth was manually held open. Computed tomography, rhinoscopy, and fluoroscopy were used to confirm a diagnosis of nasopharyngeal stenosis. The dog was anesthetized, and balloon dilatation of the stenosis was performed. Prednisone was prescribed for 4 weeks after the procedure to decrease fibrous tissue formation. Although the dog was initially improved, signs recurred 3.5 weeks later, and balloon dilatation was repeated. This time, however, triamcinolone was injected into the area of stenosis at the end of the dilatation procedure. Two months later, although the dog did not have clinical signs of stridor, a third dilatation procedure was performed because mild stenosis was seen on follow-up computed tomographic images; again, triamcinolone was injected into the area of stenosis at the end of the dilatation procedure. Three and 6 months after the third dilatation procedure, the dog reportedly was clinically normal. Findings suggest that balloon dilatation may be an effective treatment for nasopharyngeal stenosis in dogs.

  10. False coronary dissection with the new Monorail angioplasty balloon catheter.

    Science.gov (United States)

    Esplugas, E; Cequier, A R; Sabaté, X; Jara, F

    1990-01-01

    During percutaneous transluminal coronary angioplasty, the appearance of persistent staining in the vessel by contrast media suggests coronary dissection. We report seven patients in whom a false image of severe coronary dissection was observed during angioplasty performed with the new Monorail balloon catheter. This image emerges at the moment of balloon inflation, is distally located to the balloon, and disappears with balloon catheter deflation. No complications were associated with the appearance of this image.

  11. Thromboembolic events associated with single balloon-, double balloon-, and stent-assisted coil embolization of asymptomatic unruptured cerebral aneurysms: evaluation with diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Takigawa, Tomoji; Suzuki, Kensuke; Sugiura, Yoshiki; Suzuki, Ryotaro; Takano, Issei; Shimizu, Nobuyuki; Tanaka, Yoshihiro; Hyodo, Akio

    2014-01-01

    The introduction of the balloon remodeling and stent-assisted technique has revolutionized the approach to coil embolization for wide-neck aneurysms. The purpose of this study was to determine the frequency of thromboembolic events associated with single balloon-assisted, double balloon-assisted, and stent-assisted coil embolization for asymptomatic unruptured aneurysms. A retrospective review was undertaken by 119 patients undergoing coiling with an adjunctive technique for unruptured saccular aneurysms (64 single balloon, 12 double balloon, 43 stent assisted). All underwent diffusion-weighted imaging (DWI) within 24 h after the procedure. DWI showed hyperintense lesions in 48 (40 %) patients, and ten (21 %) of these patients incurred neurological deterioration (permanent, two; transient, eight). Hyperintense lesions were detected significantly more often in procedures with the double balloon-assisted technique (7/12, 58 %) than with the single balloon-assisted technique (16/64, 25 %, p = 0.05). Occurrence of new lesions was significantly higher with the use of stent-assisted technique (25/43, 58 %) than with the single balloon-assisted technique (p = 0.001). Symptomatic ischemic rates were similar between the three groups. The increased number of microcatheters was significantly related to the DWI abnormalities (two microcatheters, 15/63 (23.8 %); three microcatheters, 20/41 (48.8 %) (p = 0.008); four microcatheters, 12/15 (80 %) (p = 0.001)). Thromboembolic events detected on DWI related to coil embolization for unruptured aneurysms are relatively common, especially in association with the double balloon-assisted and stent-assisted techniques. Furthermore, the number of microcatheters is highly correlated with DWI abnormalities. The high rate of thromboembolic events suggests the need for evaluation of platelet reactivity and the addition or change of antiplatelet agents. (orig.)

  12. High-pressure balloon valvuloplasty for severe pulmonary valve stenosis: a prospective observational pilot study in 25 dogs.

    Science.gov (United States)

    Belanger, Catherine; Gunther-Harrington, Catherine T; Nishimura, Satoko; Oldach, Maureen S; Fousse, Samantha L; Visser, Lance C; Stern, Joshua A

    2018-04-01

    We aimed to evaluate safety and efficacy of high-pressure balloon valvuloplasty (HPBVP) for treatment of canine severe pulmonary valve stenosis (PS). A secondary aim was to provide pre-procedure predictors of success. Twenty-five dogs. Prospective observational study. Dogs with severe PS (echocardiographically derived trans-pulmonary peak/maximum pressure gradient (EDPG) ≥80 mmHg) were recruited. All dogs underwent echocardiography before and 20-24hrs after HPBVP using a high-pressure balloon with rated burst pressures ranging from 12 to 18 ATM. Procedural success was defined as a post-HPBVP EDPG reduction of ≥50% or reduction into at least the moderate category of PS (50-79 mmHg). Optimal result was defined as a post-procedural EDPG ≤30 mmHg. Initial median (IQR) EDPG for all dogs was 96 (88, 127) mmHg with a post-operative median of 48 (36, 65) mmHg. The median EDPG reduction provided by HPBVP was 63% (39, 68); procedural success rate was 92% (23 dogs). Optimal results were achieved in 56% (14 dogs). There were no significant correlations between EDPG reduction and valve morphology (Type A and Type B) or severity of right ventricular hypertrophy. Pulmonary valve annulus diameter was the only echocardiographic variable that was significantly correlated to EDPG reduction (p = 0.02; r = -0.46). No dog experienced any anesthetic or surgical complications, and all patients survived the procedure. In this cohort of 25 dogs with severe PS, HPBVP was safe and effective. The procedural success rate and high number of optimal results achieved with HPBVP suggest future randomized controlled trials comparing HPBVP to conventional valvuloplasty are warranted. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Adjustable continence balloons

    DEFF Research Database (Denmark)

    Kjær, Line; Fode, Mikkel; Nørgaard, Nis

    2012-01-01

    Abstract Objective. This study aimed to evaluate the results of the Danish experience with the ProACT urinary continence device inserted in men with stress urinary incontinence. Material and methods. The ProACT was inserted in 114 patients. Data were registered prospectively. The main endpoints...... in urinary leakage > 50% was seen in 72 patients (80%). Complications were seen in 23 patients. All of these were treated successfully by removal of the device in the outpatient setting followed by replacement of the device. Another eight patients had a third balloon inserted to improve continence further....... Fourteen patients (12%) ended up with an artificial sphincter or a urethral sling. Sixty patients (63%) experienced no discomfort and 58 (61%) reported being dry or markedly improved. Overall, 50 patients (53%) reported being very or predominantly satisfied. Conclusions. Adjustable continence balloons seem...

  14. Analysis of current diffusive ballooning mode

    International Nuclear Information System (INIS)

    Yagi, M.; Azumi, M.; Itoh, K.; Itoh, S.; Fukuyama, A.

    1993-04-01

    The current diffusive ballooning mode is analysed in the tokamak plasma. This mode is destabilized by the current diffusivity (i.e., the electron viscosity) and stabilized by the thermal conductivity and ion viscosity. By use of the ballooning transformation, the eigenmode equation is solved. Analytic solution is obtained by the strong ballooning limit. Numerical calculation is also performed to confirm the analytic theory. The growth rate of the mode and the mode structure are analysed. The stability boundary is derived in terms of the current diffusivity, thermal conductivity, ion viscosity and the pressure gradient for the given shear parameter. This result is applied to express the thermal conductivity in terms of the pressure gradient, magnetic configurational parameters (such as the safety factor, shear and aspect ratio) and the Prandtl numbers. (author)

  15. Numerical research on the thermal performance of high altitude scientific balloons

    International Nuclear Information System (INIS)

    Dai, Qiumin; Xing, Daoming; Fang, Xiande; Zhao, Yingjie

    2017-01-01

    Highlights: • A model is presented to evaluate the IR radiation between translucent surfaces. • Comprehensive ascent and thermal models of balloons are established. • The effect of IR transmissivity on film temperature distribution is unneglectable. • Atmospheric IR radiation is the primary thermal factor of balloons at night. • Solar radiation is the primary thermal factor of balloons during the day. - Abstract: Internal infrared (IR) radiation is an important factor that affects the thermal performance of high altitude balloons. The internal IR radiation is commonly neglected or treated as the IR radiation between opaque gray bodies. In this paper, a mathematical model which considers the IR transmissivity of the film is proposed to estimate the internal IR radiation. Comprehensive ascent and thermal models for high altitude scientific balloons are established. Based on the models, thermal characteristics of a NASA super pressure balloon are simulated. The effects of film IR property on the thermal behaviors of the balloon are discussed in detail. The results are helpful for the design and operation of high altitude scientific balloons.

  16. Palliative balloon dilation of pulmonic stenosis in a dog with tetralogy of Fallot.

    Science.gov (United States)

    Weder, C; Ames, M; Kellihan, H; Bright, J; Orton, C

    2016-09-01

    A 6-month-old Beagle with tetralogy of Fallot underwent balloon valvuloplasty of the pulmonary valve. Balloon valvuloplasty was successful and resulted in palliation of clinical signs and an improved quality of life for approximately 9 months. After 9 months, the dog became symptomatic and a modified Blalock-Taussig shunt procedure was successfully performed. Based on this report, balloon valvuloplasty in dogs with tetralogy of Fallot appears to be a feasible technique that may result in improvement of clinical signs. In addition, it may allow for the delay of the more invasive surgical palliation and provide time for weight gain and development of the pulmonary vascular bed for greater ease of surgical shunt creation. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Upgrading inflatable door seals

    International Nuclear Information System (INIS)

    Sykes, T.M.; Metcalfe, R.; Welch, L.A.; Josefowich, J.M.

    1997-01-01

    Inflatable door seals are used for airlocks in CANDU stations. They have been a significant source of unreliability and maintenance cost. A program is underway to improve their performance and reliability, backed by environmental qualification testing. Only commercial products and suppliers existed in 1993. For historical reasons, these 'existing products' did not use the most durable material then available. In hindsight, neither had they been adapted nor optimized to combat conditions often experienced in the plants-sagging doors, damaged sealing surfaces, and many thousands of openings and closings per year. Initial attempts to involve the two existing suppliers in efforts to upgrade these seals were unsuccessful. Another suitable supplier had therefore to be found, and a 'new,' COG-owned seal developed; this was completed in 1997. This paper summarizes its testing, along with that of the two existing products. Resistance to aging has been improved significantly. Testing has shown that an accident can be safely withstood after 10 years of service or 40,000 openings-closings, whichever comes first. AECL's Fluid Sealing Technology Unit (FSTU) has invested in the special moulds, test fixtures and other necessary tooling and documentation required to begin commercial manufacture of this new quality product. Accordingly, as with FSTU's other nuclear products such as pump seals, the long-term supply of door seals to CANDU plants is now protected from many external uncertainties-e.g., commercial products being discontinued, materials being changed, companies going out of business. Manufacturing to AECL's detailed specifications is being subcontracted to the new supplier. FSTU is performing the quality surveillance, inspection, testing, and customer service activities concomitant with direct responsibility for supply to the plants. (author)

  18. A "Global Radiosonde and tracked-balloon Archive on Sixteen Pressure levels" (GRASP) going back to 1905 – Part 2: homogeneity adjustments for pilot balloon and radiosonde wind data

    OpenAIRE

    L. Ramella Pralungo; L. Haimberger

    2014-01-01

    This paper describes the comprehensive homogenization of the "Global Radiosonde and tracked balloon Archive on Sixteen Pressure levels" (GRASP) wind records. Many of those records suffer from artificial shifts that need to be detected and adjusted before they are suitable for climate studies. Time series of departures between observations and the National Atmospheric and Oceanic Administration 20th-century (NOAA-20CR) surface pressure only reanalysis have been calculated...

  19. Basic development of a small balloon-mounted telemetry and its operation system by university students

    Science.gov (United States)

    Yamamoto, Masa-yuki; Kakinami, Yoshihiro; Kono, Hiroki

    In Japan, the high altitude balloon for scientific observation has been continuously launched by JAXA. The balloon has a possibility to reach 50 km altitude without tight environmental condition for onboard equipments, operating with a cost lower than sounding rockets, however, development of the large-scale scientific observation balloons by university laboratories is still difficult. Being coupled with recent improvement of semiconductor sensors, laboratory-basis balloon experiments using small weather balloons has been becoming easily in these years. Owing to an advantage of wide land fields in continental regions, the launch of such small balloons has become to be carried out many times especially in continental countries (e.g. Near Space Ventures, Inc., 2013). Although the balloon is very small as its diameter of 6 feet, excluding its extra buoyancy and the weight of the balloon itself, it is expected that about 2 kg loading capacity is remained for payloads to send it up to about 35 km altitude. However, operation of such balloons in Japan is not in general because precise prediction of a landing area of the payload is difficult, thus high-risk situation for balloon releases is remained. In this study, we aim to achieve practical engineering experiments of weather balloons in Japan to be used for scientific observation within university laboratory level as an educational context. Here we report an approach of developing many devices for a small tethered balloon currently in progress. We evaluated an accuracy of altitude measurement by using a laboratory developed altitude data logger system that consists of a GPS-module and a barometric altimeter. Diameter of the balloon was about 1.4 m. Being fulfilled with about 1440 L helium, it produced buoyancy of about 15.7 N. Taking into account of total weight including the mooring equipments, available payload mass becomes to be about 1100 g. Applying an advantage of a 3D printer of FDM (Fused Deposition Modeling

  20. Gamma Ray Large Area Space Telescope (GLAST) Balloon Flight Engineering Model: Overview

    Science.gov (United States)

    Thompson, D. J.; Godfrey, G.; Williams, S. M.; Grove, J. E.; Mizuno, T.; Sadrozinski, H. F.-W.; Kamae, T.; Ampe, J.; Briber, Stuart; Dann, James; hide

    2001-01-01

    The Gamma Ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT) is a pair-production high-energy (greater than 20 MeV) gamma-ray telescope being built by an international partnership of astrophysicists and particle physicists for a satellite launch in 2006, designed to study a wide variety of high-energy astrophysical phenomena. As part of the development effort, the collaboration has built a Balloon Flight Engineering Model (BFEM) for flight on a high-altitude scientific balloon. The BFEM is approximately the size of one of the 16 GLAST-LAT towers and contains all the components of the full instrument: plastic scintillator anticoincidence system (ACD), high-Z foil/Si strip pair-conversion tracker (TKR), CsI hodoscopic calorimeter (CAL), triggering and data acquisition electronics (DAQ), commanding system, power distribution, telemetry, real-time data display, and ground data processing system. The principal goal of the balloon flight was to demonstrate the performance of this instrument configuration under conditions similar to those expected in orbit. Results from a balloon flight from Palestine, Texas, on August 4, 2001, show that the BFEM successfully obtained gamma-ray data in this high-background environment.

  1. Development of radioactive 166Ho-coated balloon and its dose estimation

    International Nuclear Information System (INIS)

    Park, K. B.; Kim, K. H.; Hong, Y. D.; Park, E. W.

    2000-01-01

    The use of balloon with radioisotope is a promising method to prevent restenosis after transluminal coronary arterial angioplasty or stent implantation. In this study, we have developed a new radioactive coated balloon, which is prepared by coating the surface of existing balloon with 166 Ho instead of being filled with beta sources which emit high energy beta-particles for the purpose of the delivery of sufficient radiation to the vessel wall. To estimate the safety of 166 Ho-coated balloon, leaching test and radiation resistance test of the balloon were performed. The absorbed dose distributions around the 166 Ho-coated balloon were estimated by means of Monte Carlo simulation and the initial activities for optimal therapeutic regimen were determined on the basis of this results

  2. Balloon Cell Urethral Melanoma: Differential Diagnosis and Management

    Directory of Open Access Journals (Sweden)

    M. McComiskey

    2015-01-01

    Full Text Available Introduction. Primary malignant melanoma of the urethra is a rare tumour (0.2% of all melanomas that most commonly affects the meatus and distal urethra and is three times more common in women than men. Case. A 76-year-old lady presented with vaginal pain and discharge. On examination, a 4 cm mass was noted in the vagina and biopsy confirmed melanoma of a balloon type. Preoperative CT showed no distant metastases and an MRI scan of the pelvis demonstrated no associated lymphadenopathy. She underwent anterior exenterative surgery and vaginectomy also. Histology confirmed a urethral nodular malignant melanoma. Discussion. First-line treatment of melanoma is often surgical. Adjuvant treatment including chemotherapy, radiotherapy, or immunotherapy has also been reported. Even with aggressive management, malignant melanoma of the urogenital tract generally has a poor prognosis. Recurrence rates are high and the mean period between diagnosis and recurrence is 12.5 months. A 5-year survival rate of less than 20% has been reported in balloon cell melanomas along with nearly 20% developing local recurrence. Conclusion. To the best of our knowledge, this case is the first report of balloon cell melanoma arising in the urethra. The presentation and surgical management has been described and a literature review provided.

  3. Ballooning Stability of the Compact Quasiaxially Symmetric Stellarator

    International Nuclear Information System (INIS)

    Redi, M.H.; Canik, J.; Dewar, R.L.; Johnson, J.L.; Klasky, S.; Cooper, W.A.; Kerbichler, W.

    2001-01-01

    The magnetohydrodynamic (MHD) ballooning stability of a compact, quasiaxially symmetric stellarator (QAS), expected to achieve good stability and particle confinement is examined with a method that can lead to estimates of global stability. Making use of fully 3D, ideal-MHD stability codes, the QAS beta is predicted to be limited above 4% by ballooning and high-n kink modes. Here MHD stability is analyzed through the calculation and examination of the ballooning mode eigenvalue isosurfaces in the 3-space [s, alpha, theta(subscript ''k'')]; s is the edge normalized toroidal flux, alpha is the field line variable, and theta(subscript ''k'') is the perpendicular wave vector or ballooning parameter. Broken symmetry, i.e., deviations from axisymmetry, in the stellarator magnetic field geometry causes localization of the ballooning mode eigenfunction, with new types of nonsymmetric, eigenvalue isosurfaces in both the stable and unstable spectrum. The isosurfaces around the most unstable points i n parameter space (well above marginal) are topologically spherical. In such cases, attempts to use ray tracing to construct global ballooning modes lead to a k-space runaway. Introduction of a reflecting cutoff in k(perpendicular) to model numerical truncation or finite Larmor radius (FLR) yields chaotic ray paths ergodically filling the allowed phase space, indicating that the global spectrum must be described using the language of quantum chaos theory. However, the isosurface for marginal stability in the cases studied are found to have a more complex topology, making estimation of FLR stabilization more difficult

  4. Planetary Balloon-Based Science Platform Evaluation and Program Implementation

    Science.gov (United States)

    Dankanich, John W.; Kremic, Tibor; Hibbitts, Karl; Young, Eliot F.; Landis, Rob

    2016-01-01

    This report describes a study evaluating the potential for a balloon-based optical telescope as a planetary science asset to achieve decadal class science. The study considered potential science achievable and science traceability relative to the most recent planetary science decadal survey, potential platform features, and demonstration flights in the evaluation process. Science Potential and Benefits: This study confirms the cost the-benefit value for planetary science purposes. Forty-four (44) important questions of the decadal survey are at least partially addressable through balloon based capabilities. Planetary science through balloon observations can provide significant science through observations in the 300 nm to 5 m range and at longer wavelengths as well. Additionally, balloon missions have demonstrated the ability to progress from concept to observation to publication much faster than a space mission increasing the speed of science return. Planetary science from a balloon-borne platform is a relatively low-cost approach to new science measurements. This is particularly relevant within a cost-constrained planetary science budget. Repeated flights further reduce the cost of the per unit science data. Such flights offer observing time at a very competitive cost. Another advantage for planetary scientists is that a dedicated asset could provide significant new viewing opportunities not possible from the ground and allow unprecedented access to observations that cannot be realized with the time allocation pressures faced by current observing assets. In addition, flight systems that have a relatively short life cycle and where hardware is generally recovered, are excellent opportunities to train early career scientists, engineers, and project managers. The fact that balloon-borne payloads, unlike space missions, are generally recovered offers an excellent tool to test and mature instruments and other space craft systems. Desired Gondola Features: Potential

  5. Aerial Deployment and Inflation System for Mars Helium Balloons

    Science.gov (United States)

    Lachenmeler, Tim; Fairbrother, Debora; Shreves, Chris; Hall, Jeffery, L.; Kerzhanovich, Viktor V.; Pauken, Michael T.; Walsh, Gerald J.; White, Christopher V.

    2009-01-01

    A method is examined for safely deploying and inflating helium balloons for missions at Mars. The key for making it possible to deploy balloons that are light enough to be buoyant in the thin, Martian atmosphere is to mitigate the transient forces on the balloon that might tear it. A fully inflated Mars balloon has a diameter of 10 m, so it must be folded up for the trip to Mars, unfolded upon arrival, and then inflated with helium gas in the atmosphere. Safe entry into the Martian atmosphere requires the use of an aeroshell vehicle, which protects against severe heating and pressure loads associated with the hypersonic entry flight. Drag decelerates the aeroshell to supersonic speeds, then two parachutes deploy to slow the vehicle down to the needed safe speed of 25 to 35 m/s for balloon deployment. The parachute system descent dynamic pressure must be approximately 5 Pa or lower at an altitude of 4 km or more above the surface.

  6. Medium-to-high prevalence of screening-detected parkinsonism in the urban area of Tehran, Iran: data from a community-based door-to-door study

    Directory of Open Access Journals (Sweden)

    Fereshtehnejad SM

    2015-02-01

    Full Text Available Seyed-Mohammad Fereshtehnejad,1,2 Mahdiyeh Shafieesabet,3 Arash Rahmani,4 Ahmad Delbari,1,5 Johan Lökk1,6 1Division of Clinical Geriatrics, Department of Neurobiology, Care Sciences, and Society (NVS, Karolinska Institutet, Stockholm, Sweden; 2Firoozgar Clinical Research Development Center (FCRDC, Firoozgar Hospital, 3Medical Student Research Committee (MSRC, Faculty of Medicine, 4Mental Health Research Center, Tehran Institute of Psychiatry, School of Behavioral Sciences and Mental Health, Iran University of Medical Sciences, Tehran, Iran; 5Iranian Research Center on Aging, University of Social Welfare and Rehabilitation, Tehran, Iran; 6Department of Geriatric Medicine, Karolinska University Hospital, Stockholm, Sweden Introduction: Parkinsonism occurs in all ethnic groups worldwide; however, there are wide variations in the prevalence rates reported from different countries, even for neighboring regions. The huge socioeconomic burden of parkinsonism necessitates the need for prevalence studies in each country. So far, there is neither data registry nor prevalence information on parkinsonism in the Iranian population. The aim of our study was to estimate the prevalence rate of probable parkinsonism in a huge urban area in Iran, Tehran using a community-based door-to-door survey.Materials and methods: We used a random multistage sampling of the households within the network of health centers consisting of 374 subunits in all 22 districts throughout the entire urban area of Tehran. Overall, 20,621 individuals answered the baseline checklist and screening questionnaire and data from 19,500 persons aged ≥30 years were entered in the final analysis. Health care professionals used a new six-item screening questionnaire for parkinsonism, which has been previously shown to have a high validity and diagnostic value in the same population.Results: A total of 157 cases were screened for parkinsonism using the validated six-item questionnaire. After

  7. Association Between Disruption of Fibrin Sheaths Using Percutaneous Transluminal Angioplasty Balloons and Late Onset of Central Venous Stenosis

    International Nuclear Information System (INIS)

    Ni, Nina; Mojibian, Hamid; Pollak, Jeffrey; Tal, Michael

    2011-01-01

    To compare the rates of central venous stenosis in patients undergoing hemodialysis who underwent disruption of fibrin sheath with percutaneous transluminal angioplasty balloons and those who underwent over-the-wire catheter exchange. This study is a retrospective review of 209 percutaneous transluminal angioplasty balloon disruption and 1304 over-the-wire catheter exchange procedures performed in 753 patients. Approval from the Human Investigations Committee was obtained for this study. Up to 10-year follow-up was performed. A χ 2 test was used to compare the rates of central venous stenosis after balloon disruption versus catheter exchange. A t-test was used to compare time to central venous stenosis development. Of the 753 patients in the study, 127 patients underwent balloon disruption of fibrin sheath and 626 had catheter exchange. Within the balloon disruption group, 18 (14.2%) of 127 patients subsequently developed central venous stenosis, compared with 44 (7.0%) of 626 in the catheter exchange group (P 2 test). Time to central venous stenosis development was approximately 3 years in both groups and not significantly different (1371 and 1010 days, P = 0.20). A total of 25.2% of patients in the balloon disruption group had four or more subsequent catheter exchanges, versus 12.6% in the catheter exchange group (P 2 test). In conclusions, there is a possible association between percutaneous transluminal angioplasty balloon disruption of fibrin sheath and late-onset central venous stenosis. Because venography was not routinely performed in catheter exchange patients, future randomized studies are necessary to confirm these findings.

  8. Gastric emptying and intragastric balloon in obese patients.

    Science.gov (United States)

    Bonazzi, P; Petrelli, M D; Lorenzini, I; Peruzzi, E; Nicolai, A; Galeazzi, R

    2005-01-01

    Intragastric balloons have been proposed to induce weight loss in obese subjects. The consequences of the balloon on gastric physiology remain poorly studied. We studied the influence of an intragastric balloon on gastric emptying in obese patients. 12 patients were included in the study, with BMI (mean +/- SD) of 38.51 +/- 4.32 kg/m2. The balloon was inserted under light anaesthesia and endoscopic control, inflated with 700 ml saline, and removed 6 months later. Body weight and gastric emptying (T1/2 and T lag) using 13C-octanoic acid breath test were monitored before balloon placement, during its permanence and 2 months after removal. Mean weight loss was: 6.2 +/- 2.3 kg after one month; 12.4 +/- 5.8 kg after 3 months; 14.4 +/- 6.6 kg after 6 months and 10.1 +/- 4.3 kg two months after BIB removal. Gastric emptying rates were significantly decreased in the first periods with balloon in place, and returned to pre-implantation values after balloon removal. T1/2 was: 87 +/- 32 min before BIB positioning, 181 +/- 91 min after 1 month, 145 +/- 99 min after 3 months, 104 +/- 50 min after 6 months and 90 +/- 43 min 2 months after removal. T lag was 36 +/- 18 min before BIB positioning, 102 +/- 82 min after 1 month, 77 +/- 53 min after 3 months, 59 +/- 28 min after 6 months and 40 +/- 21 min. 2 months after removal. BIB in obese patients seems to be a good help in following the hypo caloric diet, especially during the first three months when the gastric emptying is slower and the sense of repletion is higher. After this period gastric emptying starts to return to normal and the stomach adapts to BIB loosing efficacy in weight loss.

  9. Spectrum of ballooning instabilities in a stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, W A [Ecole Polytechnique Federale, Lausanne (Switzerland). Centre de Recherche en Physique des Plasma (CRPP); Singleton, D B [Australian National Univ., ANU Supercomputing Facility, Canberra (Australia); Dewar, R L [Australian National Univ., Canberra, ACT (Australia). Research School of Physical Sciences

    1995-08-01

    The recent revival of interest in the application of the `ballooning formalism` to low-frequency plasma instabilities has prompted a comparison of the Wentzel-Brillouin-Kramers (WKB) ballooning approximation with an (in principle) exact normal mode calculation for a three-dimensional plasma equilibrium. Semiclassical quantization, using the ideal magnetohydrodynamic (MHD) ballooning eigenvalue to provide a local dispersion relation, is applied to a ten-field period stellarator test case. Excellent qualitative agreement, and good quantitative agreement is found with predictions from the TERPSICHORE code for toroidal mode numbers from 1 to 14 and radial mode numbers from 0 to 2. The continuum bands predicted from three-dimensional WKB theory are too narrow to resolve. (author) 3 figs., 24 refs.

  10. Spectrum of ballooning instabilities in a stellarator

    International Nuclear Information System (INIS)

    Cooper, W.A.; Singleton, D.B.; Dewar, R.L.

    1995-08-01

    The recent revival of interest in the application of the 'ballooning formalism' to low-frequency plasma instabilities has prompted a comparison of the Wentzel-Brillouin-Kramers (WKB) ballooning approximation with an (in principle) exact normal mode calculation for a three-dimensional plasma equilibrium. Semiclassical quantization, using the ideal magnetohydrodynamic (MHD) ballooning eigenvalue to provide a local dispersion relation, is applied to a ten-field period stellarator test case. Excellent qualitative agreement, and good quantitative agreement is found with predictions from the TERPSICHORE code for toroidal mode numbers from 1 to 14 and radial mode numbers from 0 to 2. The continuum bands predicted from three-dimensional WKB theory are too narrow to resolve. (author) 3 figs., 24 refs

  11. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. A valve plate is suspended from the box press by four guide wheels mounted thereon. The guide wheels are fitted into inclined guide grooves formed at the valve plate and into grooved formed in the inner wall of a valve casing. A locking ball is provided at each side of the valve plate. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing, thus releasing the locking balls. The valve plate does not contact the bottom of the casing. When the box press reaches the home position, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not slide over other parts. (Yamaguchi, T.)

  12. Efficacy of pneumodilation in achalasia after failed Heller myotomy.

    Science.gov (United States)

    Saleh, C M G; Ponds, F A M; Schijven, M P; Smout, A J P M; Bredenoord, A J

    2016-11-01

    Heller myotomy is an effective treatment for the majority of achalasia patients. However, a small proportion of patients suffer from persistent or recurrent symptoms after surgery and they are usually subsequently treated with pneumodilation (PD). Data on the efficacy of PD as secondary treatment for achalasia are scarce. Therefore, this study aimed to investigate the efficacy of PD as treatment for achalasia patients suffering from persistent or recurrent symptoms after Heller myotomy. Patients with recurrent or persistent symptoms (Eckardt score >3) after Heller myotomy were selected. Patients were treated with PD, using a graded distension protocol with balloon sizes ranging from 30 to 40 mm. After each dilation symptoms were assessed to evaluate whether a subsequent dilation with a larger balloon size was required. Patients with recurrent or persistent symptoms (Eckardt score >3) after treatment with a 40-mm balloon were identified as failures. Twenty-four patients were included in total; 15 patients with achalasia type I, seven with achalasia type II and two with achalasia type III. Median relapse time was 2.5 years after Heller myotomy (IQR: 9 years and 3 months). Three patients were not suitable for PD; one patient was morbidly obese and not fit for any form of sedation and two had a siphon-shaped esophagus leaving 21 patients to treat. Eight patients were successfully treated with a single 30-mm balloon dilation (median follow-up time: 6.5 years; IQR: 7.5 years). Four patients required dilations with 30- and 35-mm balloons (median follow-up time: 11 years; IQR: 3 years). Nine patients failed on the 35-mm balloon dilation and underwent a subsequent dilation with a 40-mm balloon, and all failed on this balloon as well. Thus, PD was successful in 12 of the 21 treatable patients, resulting in a success rate of 57% for treatable patients or 50% for all patients. Baseline Eckardt scores were also higher in those that failed (median: 8; IQR: 2) than those that

  13. Large-diameter balloon dilation for the treatment of achalasia of cardia: an analysis of mid-to-long term efficacy in 80 cases

    International Nuclear Information System (INIS)

    Song Jinwen; Yin Jianguo; Yang Yan; Liu Xiaohong; Wang Zhihong

    2011-01-01

    Objective: To discuss the technical points of large-diameter (40 mm) balloon dilation in treating achalasia of cardia, and to assess its mid-to-long term efficacy. Methods: A total of 80 patients of achalasia of cardia with a disease course of 3-23 years were enrolled in this study. According to Mellow-Pinkas standard of the dysphagia grading (from 0 to Ⅳ), the patients were classified into grade Ⅰ (n=6), grade Ⅱ (n=60) and grade Ⅲ (n=14). The diagnosis was confirmed by barium meal examination in all patients. Under spraying anesthesia of pharyngeal portion with 2% lidocaine, the intensified guide wire was inserted into the stomach through mouth under fluoroscopy guidance. The Boston's balloon (40 mm in diameter) was pushed along the guidewire to the stricture site at the cardia and was gradually inflated with 15% contrast medium by using the 'graded intermittent inflation' technique. Namely, the balloon was inflated to a maximum diameter and was kept in this condition for five minute, and then the balloon was deflated for 3-5 minutes. The above procedure was repeated 2-3 times. For the severe stricture, pre-dilatation with 20-25 mm diameter balloon was carried out. As a routine, postoperative measures to prevent possible bleeding and infection were adopted. The patient was allowed to take cool liquid diet 2-3 hours after the procedure, to have semi-liquid diet within three days and then to take normal diet. The patients were followed up for 2-10 years. Results: The balloon insertion was technically successful in all of the 80 patients. The success rate of single and twice manipulations was 96.3% (77/80) and 3.7% (3/80), respectively. Postoperative rupture of the cardia region was seen in one patient, and surgical repair had to be carried out. The follow-up time ranged from 2 years to 10 years (mean 6.27 years). No recurrent stenosis occurred in all patients. The remission rate of dysphagia was 100%. The swallowing function returned to normal in 90% of

  14. Wind-Driven Montgolfiere Balloons for Mars

    Science.gov (United States)

    Jones, Jack A.; Fairbrother, Debora; Lemieux, Aimee; Lachenmeier, Tim; Zubrin, Robert

    2005-01-01

    Solar Montgolfiere balloons, or solar-heated hot air balloons have been evaluated by use on Mars for about 5 years. In the past, JPL has developed thermal models that have been confirmed, as well as developed altitude control systems to allow the balloons to float over the landscape or carry ground sampling instrumentation. Pioneer Astronautics has developed and tested a landing system for Montgolfieres. JPL, together with GSSL. have successfully deployed small Montgolfieres (<15-m diameter) in the earth's stratosphere, where conditions are similar to a Mars deployment. Two larger Montgolfieres failed, however, and a series of larger scale Montgolfieres is now planned using stronger, more uniform polyethylene bilaminate, combined with stress-reducing ripstitch and reduced parachute deceleration velocities. This program, which is presently under way, is a joint effort between JPL, WFF, and GSSL, and is planned for completion in three years.

  15. Removing Nasal Packing in Epistaxis: What to Do in the Case of an Undeflatable Foley Catheter Balloon

    Directory of Open Access Journals (Sweden)

    Gaspar-Sobrinho, Fernando Pena

    2014-01-01

    Full Text Available Introduction Undeflatable Foley catheter balloons adapted for use as nasal packing in epistaxis represent a possible complication. Case Reports We report on three cases in which Foley catheter balloons adapted for use as posterior nasal packing in epistaxis failed to deflate. In one patient, deflation was achieved by simply using the fingertips to massage the segment of the catheter collapsed by the fixation device. In the second case, the Foley balloon was removed by the oral route after sectioning the catheter. In the third patient, the Foley catheter was successfully deflated after sectioning. Discussion The probable causes of the undeflatable balloons in these cases were a blockage or lumen collapse of the balloon or a malfunction in the valve system. Although no definitive method has been established for dealing with this complication, the options proposed are the following: manipulation to restore the permeability of the segment of the catheter collapsed by the fixation device, if this is the case; sectioning the catheter or inserting a stiletto catheter; bursting the balloon; or removing it by the oral route. The latter option is apparently the most appropriate for the otolaryngologist in cases unrelated to simple collapse caused by the fixation device.

  16. Innovations in Balloon Catheter Technology in Rhinology.

    Science.gov (United States)

    D'Anza, Brian; Sindwani, Raj; Woodard, Troy D

    2017-06-01

    Since being introduced more than 10 years ago, balloon catheter technology (BCT) has undergone several generations of innovations. From construction to utilization, there has been a myriad of advancements in balloon technology. The ergonomics of the balloon dilation systems have improved with a focus on limiting the extra assembly. "Hybrid" BCT procedures have shown promise in mucosal preservation, including treating isolated complex frontal disease. Multiple randomized clinical trials report improved long-term outcomes in stand-alone BCT, including in-office use. The ever-expanding technological innovations ensure BCT will be a key component in the armamentarium of the modern sinus surgeon. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Usage of radiography techniques for restoration of Cizre Mardin Ulucami door

    International Nuclear Information System (INIS)

    Tugrul, B.; Sungur, F.; Gorkem, A.; Olcer, N.

    1986-01-01

    In this study, one of the two sections of Cizre-Mardin Ulucami door is investigated by x-ray radiography technique whether it has some patterns similar to those which were discovered during the restoration of the first section of the door. Some painted and traced parts have been fixed and torn down, cleared and investigated. In the study, many pieces of the first part of the door including the second door have been investigated by x-ray radiography technique and have been evaluated. Furthermore, neutrography has been applied on some painted parts for the investigation of traces of painting. (author)

  18. Acute stent recoil and optimal balloon inflation strategy: an experimental study using real-time optical coherence tomography.

    Science.gov (United States)

    Kitahara, Hideki; Waseda, Katsuhisa; Yamada, Ryotaro; Otagiri, Kyuhachi; Tanaka, Shigemitsu; Kobayashi, Yuhei; Okada, Kozo; Kume, Teruyoshi; Nakagawa, Kaori; Teramoto, Tomohiko; Ikeno, Fumiaki; Yock, Paul G; Fitzgerald, Peter J; Honda, Yasuhiro

    2016-06-12

    Our aim was to evaluate stent expansion and acute recoil at deployment and post-dilatation, and the impact of post-dilatation strategies on final stent dimensions. Optical coherence tomography (OCT) was performed on eight bare metal platforms of drug-eluting stents (3.0 mm diameter, n=6 for each) during and after balloon inflation in a silicone mock vessel. After nominal-pressure deployment, a single long (30 sec) vs. multiple short (10 sec x3) post-dilatations were performed using a non-compliant balloon (3.25 mm, 20 atm). Stent areas during deployment with original delivery systems were smaller in stainless steel stents than in cobalt-chromium and platinum-chromium stents (pstrategies showed a significant impact on final stent expansion.

  19. Stabilization of ballooning modes with sheared toroidal rotation

    International Nuclear Information System (INIS)

    Miller, R.L.; Waelbroeck, F.L.; Hassam, A.B.; Waltz, R.E.

    1995-01-01

    Stabilization of magnetohydrodynamic ballooning modes by sheared toroidal rotation is demonstrated using a shifted circle equilibrium model. A generalized ballooning mode representation is used to eliminate the fast Alfven wave, and an initial value code solves the resulting equations. The s-α diagram (magnetic shear versus pressure gradient) of ballooning mode theory is extended to include rotational shear. In the ballooning representation, the modes shift periodically along the field line to the next point of unfavorable curvature. The shift frequency (dΩ/dq, where Ω is the angular toroidal velocity and q is the safety factor) is proportional to the rotation shear and inversely proportional to the magnetic shear. Stability improves with increasing shift frequency and direct stable access to the second stability regime occurs when this frequency is approximately one-quarter to one-half the Alfven frequency, ω A =V A /qR. copyright 1995 American Institute of Physics

  20. Analysis of the ballooning deformation of an internally pressurized thin-wall tube during fast thermal transients

    International Nuclear Information System (INIS)

    Lin, E.I.H.

    1977-01-01

    A large-strain time-dependent thermoplastic analysis has been developed for the ballooning deformation of a thin-wall tube subjected to internal pressure, axial loading, and fast thermal transients. This deformation initiates with the onset of plastic instability in the material, the onset being determined by a plastic-instability criterion for strain-rate sensitive materials. The interaction among the local ballooning geometry, the state of stress, and the plastic flow process was considered, and integration of the flow equations yields the local curvature and the states of stress and strain in the vicinity of the maximum ballooning site. The effects of axial constraint and heating rate were also discussed. The analysis was applied to a LWR Zircaloy cladding subjected to a constant heating rate and a range of internal pressures. The results agree very well with experimental strain-time data obtained from tube-burst tests. In most cases, the time of rupture was accurately predicted despite the lack of complete material-property data

  1. Percutaneous transhepatic balloon dilation of biliary-enteric anastomotic strictures after surgical repair of iatrogenic bile duct injuries.

    Directory of Open Access Journals (Sweden)

    Andrew Y Lee

    Full Text Available PURPOSE: To evaluate the efficacy of percutaneous balloon dilation of biliary-enteric anastomotic strictures resulting from surgical repair of laparoscopic cholecystectomy-related bile duct injuries. MATERIAL AND METHODS: A total of 61 patients were referred to our institution from 1995 to 2010 for treatment of obstruction at the biliary-enteric anastomosis following surgical repair of laparoscopic cholecystectomy-related bile duct injuries. Of these 61 patients, 27 underwent surgical revision upon stricture diagnosis, and 34 patients were managed using balloon dilation. Of these 34 patients, 2 were lost to follow up, leaving 32 patients for analysis. The primary study objective was to determine the clinical success rate of balloon dilation of biliary-enteric anastomotic strictures. Secondary study objectives included determining anastomosis patency, rates of stricture recurrence following treatment, and morbidity. RESULTS: Balloon dilation of biliary-enteric anastomotic strictures was clinically successful in 21 of 32 patients (66%. Anastomotic stricture recurred in one of 21 patients (5% after an average of 13.1 years of follow-up. Patients who were unsuccessfully managed with balloon dilation required significantly more invasive procedures (6.8 v. 3.4; p = 0.02 and were left with an indwelling biliary catheter for a significantly longer period of time (8.8 v. 2.0 months; p = 0.02 than patients whose strictures could be resolved by balloon dilation. No significant differences in the number of balloon dilations performed (p = 0.17 or in the maximum balloon diameter used (p = 0.99 were demonstrated for patients with successful or unsuccessful balloon dilation outcomes. CONCLUSION: Percutaneous balloon dilation of anastomotic biliary strictures following surgical repair of laparoscopic cholecystectomy-related injuries may result in lasting patency of the biliary-enteric anastomosis.

  2. Balloon-Borne Infrasound Detection of Energetic Bolide Events

    Science.gov (United States)

    Young, Eliot F.; Ballard, Courtney; Klein, Viliam; Bowman, Daniel; Boslough, Mark

    2016-10-01

    Infrasound is usually defined as sound waves below 20 Hz, the nominal limit of human hearing. Infrasound waves propagate over vast distances through the Earth's atmosphere: the CTBTO (Comprehensive Nuclear-Test-Ban Treaty Organization) has 48 installed infrasound-sensing stations around the world to detect nuclear detonations and other disturbances. In February 2013, several CTBTO infrasound stations detected infrasound signals from a large bolide that exploded over Chelyabinsk, Russia. Some stations recorded signals that had circumnavigated the Earth, over a day after the original event. The goal of this project is to improve upon the sensitivity of the CTBTO network by putting microphones on small, long-duration super-pressure balloons, with the overarching goal of studying the small end of the NEO population by using the Earth's atmosphere as a witness plate.A balloon-borne infrasound sensor is expected to have two advantages over ground-based stations: a lack of wind noise and a concentration of infrasound energy in the "stratospheric duct" between roughly 5 - 50 km altitude. To test these advantages, we have built a small balloon payload with five calibrated microphones. We plan to fly this payload on a NASA high-altitude balloon from Ft Sumner, NM in August 2016. We have arranged for three large explosions to take place in Socorro, NM while the balloon is aloft to assess the sensitivity of balloon-borne vs. ground-based infrasound sensors. We will report on the results from this test flight and the prospects for detecting/characterizing small bolides in the stratosphere.

  3. Balloon catheter dilatation in esophageal achalasia: long term follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Cheol Yong; Park, Hyun Mee; Kim, So Eun; Lee, Shin Hyung; Kim, Seung Hyeon; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    1994-12-15

    To evaluate the clinical efficacy of balloon catheter dilatation in the treatment of esophageal achalasia. Seven patients(three males and four females) with esopha-geal achalasia were treated with balloon catheter dilatation. Balloon catheters of variable sizes were used depending on patient's conditions. The patients were followed up over a period of 12-39 months. Balloon catheter dilatation in esophageal achalasia was successful in all patients without esophageal perforation. All patients were relieved from dysphagia. Recurrence was not found in 5 patients on long term follow-up study, but was seen in 2 patients after 18 and 21 months, respectively. Balloon catheter dilatation was a safe and effective method in the treatment of esophageal achalasia with low recurrence rate of 29% on follow-up study.

  4. Balloon catheter dilatation in esophageal achalasia: long term follow-up

    International Nuclear Information System (INIS)

    Shin, Cheol Yong; Park, Hyun Mee; Kim, So Eun; Lee, Shin Hyung; Kim, Seung Hyeon; Lee, Chang Joon

    1994-01-01

    To evaluate the clinical efficacy of balloon catheter dilatation in the treatment of esophageal achalasia. Seven patients(three males and four females) with esopha-geal achalasia were treated with balloon catheter dilatation. Balloon catheters of variable sizes were used depending on patient's conditions. The patients were followed up over a period of 12-39 months. Balloon catheter dilatation in esophageal achalasia was successful in all patients without esophageal perforation. All patients were relieved from dysphagia. Recurrence was not found in 5 patients on long term follow-up study, but was seen in 2 patients after 18 and 21 months, respectively. Balloon catheter dilatation was a safe and effective method in the treatment of esophageal achalasia with low recurrence rate of 29% on follow-up study

  5. CdZnTe background measurements at balloon altitudes with PoRTIA

    International Nuclear Information System (INIS)

    Parsons, A.; Barthelmy, S.; Bartlett, L.; Gehrels, N.; Naya, J.; Stahle, C.M.; Tueller, J.; Teegarden, B.

    2004-01-01

    Measurements of the CdZnTe internal background at balloon altitudes are essential to determine which physical processes make the most important background contributions. We present results from CdZnTe background measurements made by PoRTIA, a small CdZnTe balloon instrument that was flown three times in three different shielding configurations. PoRTIA was passively shielded during its first flight from Palestine, Texas and actively shielded as a piggyback instrument on the GRIS balloon experiment during its second and third flights from Alice Springs, Australia, using the thick GRIS NaI anticoincidence shield. A significant CdZnTe background reduction was achieved during the third flight with PoRTIA placed completely inside the GRIS shield and blocking crystal, and thus completely surrounded by 15 cm of NaI. A unique balloon altitude background data set is provided by CdZnTe and Ge detectors simultaneously surrounded by the same thick anticoincidence shield; the presence of a single coaxial Ge detector inside the shield next to PoRTIA allowed a measurement of the ambient neutron flux inside the shield throughout the flight. These neutrons interact with the detector material to produce isomeric states of the Cd, Zn, and Te nuclei that radiatively decay; calculations are presented to determine the relative contribution of these decays to the fully shielded CdZnTe background measured by PoRTIA

  6. Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Hoshiai, Sodai, E-mail: hoshiai@sb4.so-net.ne.jp; Mori, Kensaku; Ishiguro, Toshitaka; Konishi, Takahiro; Uchikawa, Yoko [University of Tsukuba Hospital, Department of Diagnostic and Interventional Radiology (Japan); Fukuda, Kuniaki [University of Tsukuba Hospital, Department of Gastroenterology (Japan); Minami, Manabu [University of Tsukuba Hospital, Department of Diagnostic and Interventional Radiology (Japan)

    2017-04-15

    Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolization without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.

  7. Treatment of symptomatic high-grade intracranial stenoses with the balloon-expandable Pharos stent: initial experience

    International Nuclear Information System (INIS)

    Kurre, W.; Berkefeld, J.; Mesnil de Rochemont, R. du; Sitzer, M.; Neumann-Haefelin, T.

    2008-01-01

    We report our first clinical experience with a CE-marked flexible monorail balloon-expandable stent for treatment of high-grade intracranial stenoses. Between April 2006 and November 2007 21 patients with symptomatic intracranial stenoses (>70%) were treated with the PHAROS stent. In seven patients, the procedure was performed during acute stroke intervention. Procedural success, clinical complication rates and mid-term follow-up data were prospectively recorded. During a median follow-up period of 7.3 months one additional patient died of an unknown cause 3 months after the intervention. A patient with a significant residual stenosis presented with a new stroke after further progression of the residual stenosis. None of the successfully treated patients experienced ipsilateral stroke. Recanalization of intracranial stenoses with the balloon-expandable Pharos stent is technically feasible. The periprocedural complication rate and mid-term follow-up results were in the range of previously reported case series. This pilot study was limited by the small sample size and severe morbidity of the included patients. Final evaluation of the efficacy of Pharos stent treatment demands further investigation. (orig.)

  8. Design Evolution and Methodology for Pumpkin Super-Pressure Balloons

    Science.gov (United States)

    Farley, Rodger

    The NASA Ultra Long Duration Balloon (ULDB) program has had many technical development issues discovered and solved along its road to success as a new vehicle. It has the promise of being a sub-satellite, a means to launch up to 2700 kg to 33.5 km altitude for 100 days from a comfortable mid-latitude launch point. Current high-lift long duration ballooning is accomplished out of Antarctica with zero-pressure balloons, which cannot cope with the rigors of diurnal cycles. The ULDB design is still evolving, the product of intense analytical effort, scaled testing, improved manufacturing, and engineering intuition. The past technical problems, in particular the s-cleft deformation, their solutions, future challenges, and the methodology of pumpkin balloon design will generally be described.

  9. Large window median filtering on Clip7

    Energy Technology Data Exchange (ETDEWEB)

    Mathews, K N

    1983-07-01

    Median filtering has been found to be a useful operation to perform on images in order to reduce random noise while preserving edges of objects. However, in some cases, as the resolution of the image increases, so too does the required window size of the filter. For parallel array processors, this leads to problems when dealing with the large amount of data involved. That is to say that there tend to be problems over slow access of data from pixels over a large neighbourhood, lack of available storage of this data during the operation and long computational times for finding the median. An algorithm for finding the median, designed for use on byte wide architecture parallel array processors is presented together with its implementation on Clip7, a scanning array of such processors. 6 references.

  10. Bakri balloon as a uterus preserving treatment of uncontrollable haemorrhage one month post-partum

    DEFF Research Database (Denmark)

    Bonnici, Mia; Markauskas, Algirdas; Munk, Torben

    2014-01-01

    In this case Bakri balloon was used to stop haemorrhage one month post-partum. The case introduces the use of this device outside usual indications. A 27-year-old woman was admitted several times with vaginal bleeding after caesarean section. She was treated pharmacologically and with curettage. ....... One month post-partum hysteroscopic removal of placental tissue was done. During this uncontrollable haemorrhage occurred and hysterectomy was considered. An attempt to save the uterus with Bakri balloon was made succesfully....

  11. Euso-Balloon: A pathfinder mission for the JEM-EUSO experiment

    Energy Technology Data Exchange (ETDEWEB)

    Osteria, Giuseppe, E-mail: osteria@na.infn.it [Istituto Nazionale di Fisica Nucleare Sezione di Napoli, Naples (Italy); Scotti, Valentina [Istituto Nazionale di Fisica Nucleare Sezione di Napoli, Naples (Italy); Università di Napoli Federico II, Dipartimento di Fisica, Naples (Italy)

    2013-12-21

    EUSO-Balloon is a pathfinder mission for JEM-EUSO, the near-UV telescope proposed to be installed on board the ISS in 2017. The main objective of this pathfinder mission is to perform a full scale end-to-end test of all the key technologies and instrumentation of JEM-EUSO detectors and to prove the entire detection chain. EUSO-Balloon will measure the atmospheric and terrestrial UV background components, in different observational modes, fundamental for the development of the simulations. Through a series of flights performed by the French Space Agency CNES, EUSO-Balloon also has the potential to detect Extensive Air Showers (EAS) from above. EUSO-Balloon will be mounted in an unpressurized gondola of a stratospheric balloon. We will describe the instrument and the electronic system which performs instrument control and data management in such a critical environment.

  12. Usefulness of cutting balloon angioplasty for the treatment of congenital heart defects.

    Science.gov (United States)

    Kusa, Jacek; Mazurak, Magdalena; Skierska, Agnieszka; Szydlowski, Leslaw; Czesniewicz, Pawel; Manka, Lukasz

    2018-01-01

    Patients with complex congenital heart defects may have different hemodynamic prob-lems which require a variety of interventional procedures including angioplasty which involves using high-pressure balloons. After failure of conventional balloon angioplasty, cutting balloon angioplasty is the next treatment option available. The purpose of this study was to evaluate the safety and efficacy of cutting balloon angioplasty in children with different types of congenital heart defects. Cutting balloon angioplasty was performed in 28 children with different congenital heart defects. The indication for cutting balloon angioplasty was: pulmonary artery stenosis in 17 patients, creating or dilatation of interatrial communication in 10 patients, and stenosis of left subclavian artery in 1 patient. In the pulmonary arteries group there was a significant decrease in systolic blood pressure (SBP) in the proximal part of the artery from the average 74.33 ± 20.4 mm Hg to 55 ± 16.7 mm Hg (p cutting balloon angioplasty was performed after an unsuccessful classic Rashkind procedure. After cutting balloon angioplasty there was a significant widening of the interatrial communication. Cutting balloon angioplasty is a feasible and effective treatment option in different con-genital heart defects.

  13. Location and data collection for long stratospheric balloon flights

    Science.gov (United States)

    Malaterre, P.

    Stratospheric balloons capable of taking a 30 kg scientific payload to an altitude of 22 to 30 km for 1 month or more were developed. In-flight experiments were used to qualify the designs of a pumpkin shaped superpressure balloon and an infrared hot air balloon. Tracking of the flights (location and transmission of the parameters measured on board) was achieved using a telemetry gondola including an ARGOS beacon adapted for operation in the low temperatures encountered.

  14. Response of Balloon-Expandable Endoprosthetic Metallic Stents Subjected to Over-Expansion In Vitro

    International Nuclear Information System (INIS)

    Montague, B. J.; Kakimoto, W. M.; Arepally, A.; Razavi, M.; Dake, M. D.; Hofmann, L. V.

    2004-01-01

    We attempted to evaluate the in vitro behavior and performance of balloon-expandable endoprosthetic metallic stents subjected to over-expansion (OE). Seventy-two balloon-expandable endoprosthetic stents, representing 22 models from six manufacturers, were over- expanded in vitro. Stents were initially expanded to their maximum manufacturer- recommended diameter and then over-expanded incrementally to their endpoints. Endpoints for OE were either stent disarticulation or an inability to undergo further expansion despite balloon insufflation to maximum burst pressure. Measurements of stent dimensions were recorded at each overexpanded diameter and comparisons were made to manufacturer's specifications. A total of 288 balloon-driven expansions were performed on 72 stents. Sixteen stents were expanded to large diameters (≥ 16 mm), 20 stents underwent OE of 50% or greater. One model tended to disarticulate after OE greater than 50%. There were five models that had a tendency to disarticulate after minimal OE. Five models were resistant to OE (25% or less OE) but did not disarticulate. Nearly all stents showed some degree of foreshortening with OE, while 36 stents underwent foreshortening of 30% or more. Models that are not recommended for OE include Intrastent, Intrastent DoubleStrut, NIR Royale and Omniflex. Good candidates for OE include Intrastent DoubleStrut LD, Palmaz large, Medtronic Extra Support Biliary Plus and Medtronic Flexible Biliary. Palmaz XL remains the only model available for expansion from 20 to 28 mm in diameter. For the remaining stents, OE is possible, however, caution should be used

  15. Ozone profiles from tethered balloon measurements in an urban plume experiment

    Science.gov (United States)

    Youngbluth, O., Jr.; Storey, R. W.; Clendenin, C. G.; Jones, S.; Leighty, B.

    1981-01-01

    NASA Langley Research Center used two tethered balloon systems to measure ozone in the general area of Norfolk, Va. The large balloon system which has an altitude range of 1,500 meters was located at Wallops Island, Va., and the smaller balloon which has an altitude range of 900 meters was located at Chesapeake, Va. Each balloon system measured ozone, temperature, humidity, wind speed, and wind direction from ground to its maximum altitude. From these measurements and from the location of the balloon sites, areas of ozone generation and ozone transport may be inferred. The measurements which were taken during August 1979 are discussed as well as the measurement techniques.

  16. Complex Coronary Interventions with the Novel Mozec™ CTO Balloon: The MOZART Registry.

    Science.gov (United States)

    Lupi, Alessandro; Rognoni, Andrea; Schaffer, Alon; Secco, Gioel G; Bongo, Angelo S

    2015-01-01

    Mozec™ CTO is a novel semicompliant rapid-exchange PTCA balloon catheter with specific features dedicated to treat complex coronary lesions like chronic total occlusions (CTOs). However, no data have been reported about the performance of this device in an all-comers population with complex coronary lesions. We evaluated the safety and success rate of Mozec™ CTO balloon in 41 consecutive patients with chronic stable angina and complex coronary lesions (15 severe calcified coronary stenoses, 15 bifurcation lesions with planned two-stent intervention, and 11 CTOs). Safety was assessed reporting the balloon burst rate after inflation exceeding the rated burst pressure (RBP) according to the manufacturer's reference table. Success was defined as the possibility to advance the device further the target lesion. The Mozec™ CTO balloon showed an excellent performance with a 93.3% success in crossing tight and severely calcified lesions (14/15 pts), a 93.3% success in engaging jailed side branches after stent deployment across bifurcations (14/15 pts), and a 90.9% success in crossing CTO lesions (10/11 pts). The burst rate at RBP of the Mozec™ CTO balloon was 6.7% (1/15 balloons) in the tight and severely calcified lesions, 6.7% (1/15 balloons) when dilating jailed vessels, and 9.1% (1/11 balloons) in CTOs. The novel Mozec™ CTO balloon dilatation catheter showed promising results when employed to treat complex lesions in an all-comers population. Further studies should clarify if this kind of balloon might reduce the need of more costly devices like over-the-wire balloons and microcatheters for complex lesions treatment.

  17. Confounding adjustment through front-door blocking in longitudinal studies

    Directory of Open Access Journals (Sweden)

    Arvid Sjölander

    2013-03-01

    Full Text Available A common aim of epidemiological research is to estimate the causal effect of a particular exposure on a particular outcome. Towards this end, observed associations are often ‘adjusted’ for potential confounding variables. When the potential confounders are unmeasured, explicit adjustment becomes unfeasible. It has been demonstrated that causal effects can be estimated even in the presence of umeasured confounding, utilizing a method called ‘front-door blocking’. In this paper we generalize this method to longitudinal studies. We demonstrate that the method of front-door blocking poses a number of challenging statistical problems, analogous to the famous problems associ- ated with the method of ‘back-door blocking’.

  18. Landing Gear Door Liners for Airframe Noise Reduction

    Science.gov (United States)

    Jones, Michael G. (Inventor); Howerton, Brian M. (Inventor); Van De Ven, Thomas (Inventor)

    2014-01-01

    A landing gear door for retractable landing gear of aircraft includes an acoustic liner. The acoustic liner includes one or more internal cavities or chambers having one or more openings that inhibit the generation of sound at the surface and/or absorb sound generated during operation of the aircraft. The landing gear door may include a plurality of internal chambers having different geometries to thereby absorb broadband noise.

  19. Locked doors in acute inpatient psychiatry: a literature review.

    Science.gov (United States)

    van der Merwe, M; Bowers, L; Jones, J; Simpson, A; Haglund, K

    2009-04-01

    Many acute inpatient psychiatric wards in the UK are permanently locked, although this is contrary to the current Mental Health Act Code of Practice. To conduct a literature review of empirical articles concerning locked doors in acute psychiatric inpatient wards, an extensive literature search was performed in SAGE Journals Online, EBM Reviews, British Nursing Index, CINAHL, EMBASE Psychiatry, International Bibliography of the Social Sciences, Ovid MEDLINE, PsycINFO and Google, using the search terms 'open$', 'close$', '$lock$', 'door', 'ward', 'hospital', 'psychiatr', 'mental health', 'inpatient' and 'asylum'. A total of 11 empirical papers were included in the review. Both staff and patients reported advantages (e.g. preventing illegal substances from entering the ward and preventing patients from absconding and harming themselves or others) and disadvantages (e.g. making patients feel depressed, confined and creating extra work for staff) regarding locked doors. Locked wards were associated with increased patient aggression, poorer satisfaction with treatment and more severe symptoms. The limited literature available showed the urgent need for research to determine the real effects of locked doors in inpatient psychiatry.

  20. Quality of life in symptomatic cervical myelopathy after open-door laminoplasty

    Directory of Open Access Journals (Sweden)

    Rodrigo Yuiti Nakao

    2015-06-01

    Full Text Available OBJECTIVE: To analyze the results obtained by open-door laminoplasty using the Newbridge(r/Blackstone plate, in cases of myelopathy associated with cervical lordosis.METHODS: From December 2010 to October 2012, eight patients between the ages of 49 and 68 underwent open-door laminoplasty with the use of the Newbridge(r fixation system for maintenance and stabilization of the cervical laminoplasty. Minimum follow-up was four months. For the evaluation of quality of life the questionnaire SF-36 was applied at the following times: preoperative, one month and three months after surgery associated with the subjective assessment of the patient regarding satisfaction with the procedure and with the Nurick neurological scale applied prior to surgery and three months later.RESULTS: According to the SF-36, there was significant improvement in the domains functional ability, general health perceptions and emotional aspects over time; regarding physical limitations and social aspects there was no improvement in the first postoperative month, only in the third month. There were no statistically significant changes observed during the period covered by this study related to pain, vitality and mental health. According to Nurick scale, there was evidence of improvement in symptoms of cervical myelopathy. Based on the subjective evaluation of the patients, surprisingly, all patients were satisfied with the surgical procedure and the results.CONCLUSION: The open-door laminoplasty technique with rigid fixation to maintain the opening is useful in improving the symptoms of cervical myelopathy associated with lordosis, leading to improved quality of life and with a high degree of patient satisfaction and fewer complications.

  1. 78 FR 18533 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances

    Science.gov (United States)

    2013-03-27

    ... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... Hot Air Balloons Ltd female ACME threaded hose connectors, part numbers HS6139 and HS6144, installed... follows: * * * * * (c) Applicability This AD applies to Lindstrand Hot Air Balloons Ltd female ACME...

  2. 77 FR 64763 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances

    Science.gov (United States)

    2012-10-23

    ... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... propose to adopt a new airworthiness directive (AD) for certain Lindstrand Hot Air Balloons Ltd female... identified in this proposed AD, contact Lindstrand Hot Air Balloons Ltd., Maesbury Road, Oswestry, Shropshire...

  3. MHD simulation of high wavenumber ballooning-like modes in LHD

    International Nuclear Information System (INIS)

    Miura, H.; Nakajima, N.

    2008-10-01

    Dynamical growths of high-wavenumber ballooning modes are studied through full-3D nonlinear MHD simulations of the Large Helical Device. The growths of the ballooning modes are identified by studying the growth rates and the radial profiles of the Fourier coefficients of fluctuation variables. The mechanisms to weaken the growth of instability, such as the local fattening of the pressure and the energy release to the parallel kinetic energy, are found being insufficient to suppress the high-wavenumber ballooning modes. Consequently, the mean pressure profile is totally modified when the evolutions of the ballooning modes are saturated. The numerical results reveal that we need some mechanisms which do not originate from an ideal MHD to achieve a mild, saturated behaviors beyond the growths of unstable high ballooning modes in the helical device. The parallel heat conductivity is proposed as one of possible non-ideal mechanisms. (author)

  4. Hot air balloon engine

    Energy Technology Data Exchange (ETDEWEB)

    Edmonds, Ian [Solartran Pty Ltd, 12 Lentara Street, Kenmore, Brisbane 4069 (Australia)

    2009-04-15

    This paper describes a solar powered reciprocating engine based on the use of a tethered hot air balloon fuelled by hot air from a glazed collector. The basic theory of the balloon engine is derived and used to predict the performance of engines in the 10 kW to 1 MW range. The engine can operate over several thousand metres altitude with thermal efficiencies higher than 5%. The engine thermal efficiency compares favorably with the efficiency of other engines, such as solar updraft towers, that also utilize the atmospheric temperature gradient but are limited by technical constraints to operate over a much lower altitude range. The increased efficiency allows the use of smaller area glazed collectors. Preliminary cost estimates suggest a lower $/W installation cost than equivalent power output tower engines. (author)

  5. The role of scientific ballooning for exploration of the magnetosphere

    International Nuclear Information System (INIS)

    Block, L.P.; Lazutin, L.L.; Riedler, W.

    1984-11-01

    The magnetosphere is explored in situ by satellites, but measurements near the low altitude magnetospheric boundary by rockets, balloons and groundbased instruments play a very significant role. The geomagnetic field provides a frame with anisotropic wave and particle propagation effects, enabling remote sensing of the distant magnetosphere by means of balloon-borne and groundbased instruments. Examples will be given of successful studies, with coordinated satellite and balloon observations, of substorm, pulsation and other phenomena propagating both along and across the geomagnetic field. Continued efforts with sophisticated balloon-borne instrumentations should contribute substantially to our understanding of magnetospheric physics. (Author)

  6. [Application of temporary balloon blocking technique in bone tumors surgery under the aid of CT angiography].

    Science.gov (United States)

    Fang, Cheng; Hu, Yongcheng; Huang, Hongchao; Xia, Qun; Chen, Xiaopeng; Yuan, Binbin; He, Xin; Wang, Peng

    2014-10-01

    To study the value of CT angiography (CTA) in the surgical treatment of bone tumors with the temporary balloon blocking technique. A retrospective analysis was made on the clinical data of 36 bone tumor patients between April 2008 and October 2013. There were 22 males and 14 females, aged from 25 to 83 years (mean, 46 years). The tumor located at the sacrococcygeal region in 17 cases, at the ilium in 12 cases, at the pubis in 5 cases, and at the proximal femur in 2 cases. Before surgery, CTA was performed to measure the external diameter of aortaventralis and arteria iliac communis, and the distance between the low renal artery and the abdominal aortic bifurcation as well as mark the anatomical relationship between the low renal artery, the abdominal aortic bifurcation and bony landmarks of vertebral body. According to these data, suitable balloon was chosen and the balloon positioning was guided in the surgery to completely excise tumor assisted by balloon blocking technique. The CTA results showed that the external diameter of aortaventralis and arteria iliaca communis was (1.545 ± 0.248) cm and (1.060 ± 0.205) cm respectively, and the distance between the low renal artery and the abdominal aortic bifurcation was (10.818 ± 1.165) cm. The three-dimensional reconstruction showed that the opening of the low renal artery was mainly located at L1 (16/36, 44.4%) and the abdominal aortic bifurcation mainly located at L4 (22/36, 61.1%). Effective block of abdomial aorta was performed; the blood pressure obviously increased in 3 cases after balloon inflation, and pulse of the left dorsal artery of the foot decreased in 1 case after removal of balloon, which were relieved after expectant treatment. The operation time was 118-311 minutes; the intraoperative blood loss was 200-1800 mL, 21 patients were given blood transfusion, and the amount of blood transfusion was 400-1200 mL; and the aortic clamping time was 40-136 minutes. All patients were followed up 5-44 months

  7. A Rare and Serious Unforeseen Complication of Cutting Balloon Angioplasty

    Directory of Open Access Journals (Sweden)

    Praveen Vemula

    2014-01-01

    Full Text Available Cutting balloon angioplasty (CBA is one of the adept ways of treating “in-stent restenosis.” Various complications related to cutting balloon angioplasty have been reported including arterial rupture, delayed perforation and fracture of microsurgical blades. Here we report a very unusual and inadvertent extraction of a stent previously deployed in the ramus intermedius coronary branch by a cutting balloon catheter. This required repeat stenting of the same site for an underlying dissection. Even though stent extraction is a rare complication it can be serious due to dissection, perforation, and closure of the artery. Physicians performing coronary artery interventions would need to be aware of this rare and serious complication especially if any difficulty is encountered while withdrawing the cutting balloon. Therefore, after removal, cutting balloon should be examined thoroughly for possible stent dislodgment or extraction when used for “in-stent restenosis.”

  8. Modeling and Simulation of Two Wheelchair Accessories for Pushing Doors.

    Science.gov (United States)

    Abdullah, Soran Jalal; Shaikh Mohammed, Javeed

    2017-03-27

    Independent mobility is vital to individuals of all ages, and wheelchairs have proven to be great personal mobility devices. The tasks of opening and navigating through a door are trivial for healthy people, while the same tasks could be difficult for some wheelchair users. A wide range of intelligent wheelchair controllers and systems, robotic arms, or manipulator attachments integrated with wheelchairs have been developed for various applications, including manipulating door knobs. Unfortunately, the intelligent wheelchairs and robotic attachments are not widely available as commercial products. Therefore, the current manuscript presents the modeling and simulation of a novel but simple technology in the form of a passive wheelchair accessory (straight, arm-like with a single wheel, and arc-shaped with multiple wheels) for pushing doors open from a wheelchair. From the simulations using different wheel shapes and sizes, it was found that the arc-shaped accessory could push open the doors faster and with almost half the required force as compared to the arm-like accessory. Also, smaller spherical wheels were found to be best in terms of reaction forces on the wheels. Prototypes based on the arc-shaped accessory design will be manufactured and evaluated for pushing doors open and dodging or gliding other obstacles.

  9. In Situ Balloon-Borne Ice Particle Imaging in High-Latitude Cirrus

    Science.gov (United States)

    Kuhn, Thomas; Heymsfield, Andrew J.

    2016-09-01

    Cirrus clouds reflect incoming solar radiation, creating a cooling effect. At the same time, these clouds absorb the infrared radiation from the Earth, creating a greenhouse effect. The net effect, crucial for radiative transfer, depends on the cirrus microphysical properties, such as particle size distributions and particle shapes. Knowledge of these cloud properties is also needed for calibrating and validating passive and active remote sensors. Ice particles of sizes below 100 µm are inherently difficult to measure with aircraft-mounted probes due to issues with resolution, sizing, and size-dependent sampling volume. Furthermore, artefacts are produced by shattering of particles on the leading surfaces of the aircraft probes when particles several hundred microns or larger are present. Here, we report on a series of balloon-borne in situ measurements that were carried out at a high-latitude location, Kiruna in northern Sweden (68N 21E). The method used here avoids these issues experienced with the aircraft probes. Furthermore, with a balloon-borne instrument, data are collected as vertical profiles, more useful for calibrating or evaluating remote sensing measurements than data collected along horizontal traverses. Particles are collected on an oil-coated film at a sampling speed given directly by the ascending rate of the balloon, 4 m s-1. The collecting film is advanced uniformly inside the instrument so that an always unused section of the film is exposed to ice particles, which are measured by imaging shortly after sampling. The high optical resolution of about 4 µm together with a pixel resolution of 1.65 µm allows particle detection at sizes of 10 µm and larger. For particles that are 20 µm (12 pixel) in size or larger, the shape can be recognized. The sampling volume, 130 cm3 s-1, is well defined and independent of particle size. With the encountered number concentrations of between 4 and 400 L-1, this required about 90- to 4-s sampling times to

  10. Advanced Onboard Energy Storage Solution for Balloons, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Advanced Balloon Programs at NASA are looking for a potential 100 day missions at mid-altitudes. These balloons would be powered by solar panels to take advantage of...

  11. LRO-LAMP failsafe door-open performance: improving FUV measurements of dayside lunar hydration

    Science.gov (United States)

    Davis, Michael W.; Greathouse, Thomas K.; Kaufmann, David E.; Retherford, Kurt D.; Versteeg, Maarten H.

    2017-08-01

    The Lunar Reconnaissance Orbiter's (LRO) Lyman Alpha Mapping Project (LAMP) is a lightweight (6.1 kg), lowpower (4.5 W), ultraviolet spectrograph based on the Alice instruments aboard the European Space Agency's Rosetta spacecraft and NASA's New Horizons spacecraft. Its primary job is to identify and localize exposed water frost in permanently shadowed regions (PSRs) near the Moon's poles, and to characterize landforms and albedos in PSRs. LRO launched on June 18, 2009 and reached lunar orbit four days later. LAMP operated with its failsafe door closed for its first seven years in flight. The failsafe door was opened in October 2016 to increase light throughput during dayside operations at the expense of no longer having the capacity to take further dark observations and slightly more operational complexity to avoid saturating the instrument. This one-time irreversible operation was approved after extensive review, and was conducted flawlessly. The increased throughput allows measurement of dayside hydration in one orbit, instead of averaging multiple orbits together to reach enough signal-to-noise. The new measurement mode allows greater time resolution of dayside water migration for improved investigations into the source and loss processes on the lunar surface. LAMP performance and optical characteristics after the failsafe door opening are described herein, including the new effective area, wavelength solution, and resolution.

  12. Exponential Growth of Nonlinear Ballooning Instability

    International Nuclear Information System (INIS)

    Zhu, P.; Hegna, C. C.; Sovinec, C. R.

    2009-01-01

    Recent ideal magnetohydrodynamic (MHD) theory predicts that a perturbation evolving from a linear ballooning instability will continue to grow exponentially in the intermediate nonlinear phase at the same linear growth rate. This prediction is confirmed in ideal MHD simulations. When the Lagrangian compression, a measure of the ballooning nonlinearity, becomes of the order of unity, the intermediate nonlinear phase is entered, during which the maximum plasma displacement amplitude as well as the total kinetic energy continues to grow exponentially at the rate of the corresponding linear phase.

  13. Ballooning Interest in Science.

    Science.gov (United States)

    Kim, Hy

    1992-01-01

    Presents an activity in which students construct model hot air balloons to introduce the concepts of convection current, the principles of Charles' gas law, and three-dimensional geometric shapes. Provides construction and launching instructions. (MDH)

  14. Numerical and experimental simulation of the mechanical behavior of super-pressure balloon subsystems

    Science.gov (United States)

    Siguier, J.-M.; Guigue, P.; Karama, M.; Mistou, S.; Dalverny, O.; Granier, S.

    2004-01-01

    Long duration super-pressure balloons constitute a great challenge in scientific ballooning. For any type of balloons (spherical, pumpkin, …), it is necessary to have a good knowledge of the mechanical behavior of envelopes regarding the level and the lifetime of the flight. For this reason CNES, ONERA and ENIT are carrying out a research program of modelization and experimentation in order to predict the envelope shape of a balloon in different conditions of temperature and differential pressure. This study was conducted in two parts. During the first one, we defined, with parameters obtained from unidirectional tests, the mechanical laws (elasticity, plasticity and viscosity properties of polymers) of materials involved in the envelope. These laws are introduced in a finite element code, which predicts the stress and strain status of a complex envelope structure. During the second one, we developed an experimental set-up to measure the 3D strain on a balloon subsystem, which includes envelope, assemblies and apex parts, in real flight conditions. This facility, called NIRVANA, is a 1 m 3 vacuum chamber with cooled screens equipped with a stereoscopic CCD measurement system. A 1.5 m diameter sample can be tested under differential pressure, regulated temperature (from +20 to -120 °C) and a load (up to 6 tonnes) applied on tendons. This paper presents the first results obtained from the modelizations and measurements done on an envelope sample submitted to axisymmetrical stress due to the differential pressure. This sample consists of a 50 μm multilayer polymer film with an assembly, used in 10 m diameter STRATEOLE super-pressure balloons. The modelization gives results in good accordance with the experiments and will enable us to follow this work with cold conditions, time dependence (creeping) and more complex structures.

  15. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Pretolesi, F.; Derchi, L.E. [Dept. of Radiology, University of Genoa (Italy); Redaelli, G.; Papagni, L. [IRCCS, Ist. Auxologico Italiano, Milan (Italy)

    2001-04-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  16. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    International Nuclear Information System (INIS)

    Pretolesi, F.; Derchi, L.E.; Redaelli, G.; Papagni, L.

    2001-01-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  17. Hybridization and adaptation to introduced balloon vines in an Australian soapberry bug.

    Science.gov (United States)

    Andres, J A; Thampy, P R; Mathieson, M T; Loye, J; Zalucki, M P; Dingle, H; Carroll, S P

    2013-12-01

    Contemporary adaptation of plant feeding insects to introduced hosts provides clear cases of ecologically based population divergence. In most cases the mechanisms permitting rapid differentiation are not well known. Here we study morphological and genetic variation associated with recent shifts by the Australian soapberry bug Leptocoris tagalicus onto two naturalized Neotropical balloon vines, Cardiospermum halicacabum and C. grandiflorum that differ in time since introduction. Our results show that these vines have much larger fruits than the native hosts (Whitewood tree -Atalaya hemiglauca- and Woolly Rambutan -Alectryon tomentosus-) and that bugs living on them have evolved significantly longer beaks and new allometries. Genetic analyses of mitochondrial haplotypes and amplified fragment length polymorphic (AFLP) markers indicate that the lineage of bugs on the annual vine C. halicacabum, the older introduction, is intermediate between the two subspecies of L. tagalicus found on native hosts. Moreover, where the annual vine and Whitewood tree co-occur, the morphology and genomic composition of the bugs are similar to those occurring in allopatry. These results show that hybridization provided the genetic elements underlying the strongly differentiated 'Halicacabum bugs'. In contrast, the bugs feeding on the recently introduced perennial balloon vine (C. grandiflorum) showed no evidence of admixture, and are genetically indistinguishable from the nearby populations on a native host. © 2013 John Wiley & Sons Ltd.

  18. Cutting balloon and high-pressure balloon dilation for palliative treatment of congenital double-chambered right ventricle and primary infundibular stenosis in a Golden retriever dog.

    Science.gov (United States)

    Schober, Karsten E; Rhinehart, Jaylyn; Kohnken, Rebecca; Bonagura, John D

    2017-12-01

    Combined cutting balloon and high-pressure balloon dilation was performed in a dog with a double-chambered right ventricle and severe infundibular stenosis of the right ventricular outflow tract. The peak systolic pressure gradient across the stenosis decreased by 65% after dilation (from 187 mmHg before to 66 mmHg after) affirming the intervention as successful. However, early re-stenosis occurred within 3 months leading to exercise intolerance, exercise-induced syncope, and right-sided congestive heart failure. Cutting balloon followed by high-pressure balloon dilation provided temporary but not long-term relief of right ventricular obstruction in this dog. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Identification of persons entering through the door from the accelerometers data

    OpenAIRE

    Vodopivec, Tadej

    2013-01-01

    This thesis presents a system for automatic identification of a person who walks through a door based on the information gathered with acceleration sensors, which are mounted on the door. The proccedure for automatic identification consists of four steps. In the first step, data acquisition and coordinate system rotation is performed. Coordinate system rotation is needed in order to match the direction of measured accelerations with the direction of components of the forces acting on the door...

  20. Looking for the WIMP next door

    Science.gov (United States)

    Evans, Jared A.; Gori, Stefania; Shelton, Jessie

    2018-02-01

    We comprehensively study experimental constraints and prospects for a class of minimal hidden sector dark matter (DM) models, highlighting how the cosmological history of these models informs the experimental signals. We study simple `secluded' models, where the DM freezes out into unstable dark mediator states, and consider the minimal cosmic history of this dark sector, where coupling of the dark mediator to the SM was sufficient to keep the two sectors in thermal equilibrium at early times. In the well-motivated case where the dark mediators couple to the Standard Model (SM) via renormalizable interactions, the requirement of thermal equilibrium provides a minimal, UV-insensitive, and predictive cosmology for hidden sector dark matter. We call DM that freezes out of a dark radiation bath in thermal equilibrium with the SM a WIMP next door, and demonstrate that the parameter space for such WIMPs next door is sharply defined, bounded, and in large part potentially accessible. This parameter space, and the corresponding signals, depend on the leading interaction between the SM and the dark mediator; we establish it for both Higgs and vector portal interactions. In particular, there is a cosmological lower bound on the portal coupling strength necessary to thermalize the two sectors in the early universe. We determine this thermalization floor as a function of equilibration temperature for the first time. We demonstrate that direct detection experiments are currently probing this cosmological lower bound in some regions of parameter space, while indirect detection signals and terrestrial searches for the mediator cut further into the viable parameter space. We present regions of interest for both direct detection and dark mediator searches, including motivated parameter space for the direct detection of sub-GeV DM.

  1. Temporary Percutaneous Aortic Balloon Occlusion to Enhance Fluid Resuscitation Prior to Definitive Embolization of Post-Traumatic Liver Hemorrhage

    International Nuclear Information System (INIS)

    Matsuoka, Shin; Uchiyama, Katsuhiro; Shima, Hideki; Ohishi, Sonomi; Nojiri, Yoko; Ogata, Hitoshi

    2001-01-01

    We successfully stabilized severe hemorrhagic shock following traumatic liver injury by percutaneous transcarotid supraceliac aortic occlusion with a 5 Fr balloon catheter. Then we were able to perform transfemoral embolization therapy of the hepatic arterial bleeding source. Transient aortic occlusion using a balloon catheter appears to be a useful adjunct in select cases where stabilization of the patient is necessary to allow successful selective embolization of the bleeding source

  2. Double-Balloon Catheter for Isolated Liver Perfusion: An Experimental Study

    International Nuclear Information System (INIS)

    Cwikiel, Wojciech; Bergqvist, Lennart; Harnek, Jan

    2001-01-01

    Purpose: Further development of a previously described interventional method for isolated liver perfusion (ILP) with a new double-lumen balloon catheter, and evaluation of the side-effects of such isolation.Methods: In six pigs a double-balloon occlusion catheter was placed via the transjugular approach with its tip in the portal vein. One of the balloons was positioned in the inferior vena cava (IVC), cranial to the origin of the hepatic veins and the other balloon in the portal vein. By the transfemoral approach, a single-balloon occlusion catheter was placed in the IVC caudal to the origin of the hepatic veins. A third catheter was placed by the transfemoral route with the occlusion balloon in the proper hepatic artery. After inflation of all balloons 99 Tc m -labelled human serum albumin was recirculated through the liver. The isolation was evaluated by repeated measurement of radioactivity levels in peripheral blood. Laboratory tests of liver and pancreas function, and hemoglobin, were taken before, at the end of, and 3 days after the procedure. Blood gases were tested at the beginning and end of the procedure.Results: One pig died during the procedure due to technical failure and was excluded from the study. In the other pigs leakage from the isolated liver to the systemic circulation increased slowly, up to 9.7% (mean) during 30 min of recirculation of the perfusate through the liver. Laboratory tests were normal in all pigs except insignificant acidosis directly after the procedure and the slight elevation of s-ALAT after 3 days.Conclusions: Only minor leakage from the liver to the systemic circulation was noted during ILP performed with a new, double-balloon catheter. There were no serious side effects

  3. Scheduling Trucks in a Cross-Dock with Mixed Service Mode Dock Doors

    DEFF Research Database (Denmark)

    Bodnar, Peter; Azadeh, Kaveh; Koster, René de

    2017-01-01

    The problem considered in this paper is how to schedule inbound and outbound trucks subject to time windows at a multidoor cross-dock. Dock doors can either be dedicated to inbound or outbound trucks or be capable of handling both truck types. In addition, loads are allowed to be temporarily...

  4. Rotational and frictional dynamics of the slamming of a door

    Science.gov (United States)

    Klein, Pascal; Müller, Andreas; Gröber, Sebastian; Molz, Alexander; Kuhn, Jochen

    2017-01-01

    A theoretical and experimental investigation of the rotational dynamics, including friction, of a slamming door is presented. Based on existing work regarding different damping models for rotational and oscillatory motions, we examine different forms for the (angular) velocity dependence (ωn, n = 0, 1, 2) of the frictional force. An analytic solution is given when all three friction terms are present and several solutions for specific cases known from the literature are reproduced. The motion of a door is investigated experimentally using a smartphone, and the data are compared with the theoretical results. A laboratory experiment under more controlled conditions is conducted to gain a deeper understanding of the movement of a slammed door. Our findings provide quantitative evidence that damping models involving quadratic air drag are most appropriate for the slamming of a door. Examining this everyday example of a physical phenomenon increases student motivation, because they can relate it to their own personal experience.

  5. Intra-aortic balloon shape change: effects on volume displacement during inflation and deflation.

    Science.gov (United States)

    Khir, Ashraf William; Bruti, Gianpaolo

    2013-07-01

    It has been observed that operating the intra-aortic balloon at an angle to the horizontal resulted in a reduction of the volume displaced toward the coronary arteries and compromised afterload reduction. Therefore, the aim of this work is to examine whether changing the current balloon shape, which has not been altered for 40 years, could compensate for the negative hemodynamic effects due to angulation. We tested two tapered balloons, increasing diameter (TID) and decreasing diameter (TDD), and compared the results with those obtained from a standard cylindrical balloon. The balloons were tested in vitro at 60 beats/min and a static pressure of 90 mm Hg. The balloons were operated at four angles (0°, 20°, 30°, 45°), and the pressure at three locations along the balloon (base, middle, and tip) was also measured. Flow rate upstream of the tip of the balloon was also measured to indicate the flow displaced toward the coronary circulation. The relative volume displaced toward (VUTVi) and suctioned away from (VUTVd) the simulated ascending aorta, during inflation and deflation, respectively, is reduced when a standard cylindrical balloon is operated at an angle to the horizontal. The TDD provided the greatest VUTVi and also produced the largest pulse pressure during deflation. Although the TID provided less VUTVi and VUTVd at smaller angles, it was not markedly affected by the change of angle. According to these results, different balloon shapes analyzed, with comparable volume to that of a cylindrical balloon, produced greater inflation and deflation benefits, at the horizontal and at a range of angles to the horizontal. Further investigations are required to optimize the shape of the tapered balloons to fit into the available physiological space. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  6. The Titan Sky Simulator ™ - Testing Prototype Balloons in Conditions Approximating those in Titan's Atmosphere

    Science.gov (United States)

    Nott, Julian

    This paper will describe practical work flying prototype balloons in the "The Titan Sky Simulator TM " in conditions approximating those found in Titan's atmosphere. Saturn's moon, Titan, is attracting intense scientific interest. This has led to wide interest in exploring it with Aerobots, balloons or airships. Their function would be similar to the Rovers exploring Mars, but instead of moving laboriously across the rough terrain on wheels, they would float freely from location to location. To design any balloon or airship it is essential to know the temperature of the lifting gas as this influences the volume of the gas, which in turn influences the lift. To determine this temperature it is necessary to know how heat is transferred between the craft and its surroundings. Heat transfer for existing balloons is well understood. However, Titan conditions are utterly different from those in which balloons have ever been flown, so heat transfer rates cannot currently be calculated. In particular, thermal radiation accounts for most heat transfer for existing balloons but over Titan heat transfer will be dominated by convection. To be able to make these fundamental calculations, it is necessary to get fundamental experimental data. This is being obtained by flying balloons in a Simulator filled with nitrogen gas at very low temperature, about 95° K / minus 180° C, typical of Titan's temperatures. Because the gas in the Simulator is so cold, operating at atmospheric pressure the density is close to that of Titan's atmosphere. "The Titan Sky Simulator TM " has an open interior approximately 4.5 meter tall and 2.5 meters square. It has already been operated at 95° K/-180° C. By the time of the Conference it is fully expected to have data to present from actual balloons flying at this temperature. Perhaps the most important purpose of this testing is to validate numerical [computational fluid dynamics] models being developed by Tim Colonius of Caltech. These numerical

  7. [Psychiatry with open doors. Part 1: Rational for an open door for acute psychiatry].

    Science.gov (United States)

    Sollberger, D; Lang, U E

    2014-03-01

    Despite the reform efforts of the last decades modern acute psychiatry still stands between conflicting priorities in everyday practice. The protection of patient autonomy might conflict with a regulatory mandate of psychiatry in societal contexts and the necessity of coercive measures and involuntary treatment might become problematic with respect to presumed but contentious interests of the patient. The conflicts particularly concern questions of involuntary commitment, door closing, coercive and isolation measures. Research on the topic of therapeutic effectiveness of these practices is rare. Accordingly, the practice depends on the federal state, hospital and ward and is very heterogeneous. Epidemiological prognosis predicts an increase of psychiatric disorders; however, simultaneously in terms of medical ethics the warranty of patient autonomy, shared decision-making and informed consent in psychiatry become increasingly more important. This challenges structural and practical changes in psychiatry, particularly in situations of self and third party endangerment which are outlined and a rationale for an opening of the doors in acute psychiatric wards is provided.

  8. Allegheny County Median Age at Death

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The median age at death is calculated for each municipality in Allegheny County. Data is based on the decedent's residence at the time of death, not the location...

  9. Design of experiments and equipment to test the ballooning characteristics of CANDU pressure tubes

    International Nuclear Information System (INIS)

    Forrest, C.F.; Stern, F.; Hart, R.G.

    1992-01-01

    Experiments have been planned and an apparatus has been designed to enable creep testing of end-of-life pressure tube specimens in a LOCA environment. Effects that could be studied include: annealing of irradiation damage during transient heating; effects of hydride blisters on pressure tube ballooning strains; and, effects of uniformly-distributed hydrogen content on pressure tube ballooning strains. The proposed experimental program will consist of separate effects creep tests on pressure tube sections under transient heating conditions

  10. Balloon observation of gamma-ray burst

    International Nuclear Information System (INIS)

    Nishimura, Jun; Fujii, Masami; Yamagami, Takamasa; Oda, Minoru; Ogawara, Yoshiaki

    1978-01-01

    Cosmic gamma-ray burst is an interesting high energy astrophysical phenomenon, but the burst mechanism has not been well understood. Since 1975, long duration balloon flight has been conducted to search for gamma-ray bursts and to determine the source locations. A rotating cross-modulation collimator was employed to determine the locations of sources, and four NaI(Tl) scintillation counters were employed to detect hard X-ray with energy from 20 to 200 keV. The balloon light was performed at altitude of 8.3 mb from September 28, 1977, and the observation time of 79 hours was achieved. In this experiment, the monitor counter was not mounted. The count increase was observed at 16 h 22 m 31 s JST on October 1, 1977. The event disappeared after 1 sec. The total flux is estimated to be 1.6 x 10 -6 erg/cm 2 sec at the top of the atmosphere. When this event was observed, the solar-terrestrial environment was also quiet. Thus, this event was attributed to a small gamma-ray burst. Unfortunately, the duration of the burst was so short that the position of the burst source was not able to be determined. (Yoshimori, M.)

  11. The response of superpressure balloons to gravity wave motions

    Directory of Open Access Journals (Sweden)

    R. A. Vincent

    2014-04-01

    Full Text Available Superpressure balloons (SPB, which float on constant density (isopycnic surfaces, provide a unique way of measuring the properties of atmospheric gravity waves (GW as a function of wave intrinsic frequency. Here we devise a quasi-analytic method of investigating the SPB response to GW motions. It is shown that the results agree well with more rigorous numerical simulations of balloon motions and provide a better understanding of the response of SPB to GW, especially at high frequencies. The methodology is applied to ascertain the accuracy of GW studies using 12 m diameter SPB deployed in the 2010 Concordiasi campaign in the Antarctic. In comparison with the situation in earlier campaigns, the vertical displacements of the SPB were measured directly using GPS. It is shown using a large number of Monte Carlo-type simulations with realistic instrumental noise that important wave parameters, such as momentum flux, phase speed and wavelengths, can be retrieved with good accuracy from SPB observations for intrinsic wave periods greater than ca. 10 min. The noise floor for momentum flux is estimated to be ca. 10−4 mPa.

  12. Beoordeling RWA-installatie Atrium Vertigo: Rookverspreiding door het gebouw

    NARCIS (Netherlands)

    Neuhaus, E.

    2004-01-01

    Het atrium van het Vertigo-gebouw is bouwkundig bedoeld als één groot brandcompartiment. De schuifdeuren en ramen naar aanliggende vertrekken staan echter vaak open. Hierdoor kan de rook zich in het geval van een brand in het atrium gemakkelijk door het gebouw verspreiden door een overdruk in het

  13. The development of coastal diffusion observation method with a captive balloon

    International Nuclear Information System (INIS)

    Fukuda, Masaaki; Yamada, Masaharu

    1980-03-01

    Apparatus whereby the dye cloud in a coastal area in diffusion experiment can be photographed was developed. It consists of a vinyl balloon two meters in diameter, a photographic device with the camera shutter released by wireless signals from the ground, and a winch to raise or lower the balloon. A maximum height of the balloon for taking photographs is 1000 m. During the single balloon flight, thirty photographs can be taken. With the balloon at a certain height, dye as the tracer in diffusion experiment is released at sea surface or a certain sea depth by dye-throwing means or pump, and then taking the photographs is started. Movement and diffusion of the dye are analyzed by means of the photographs taken. The apparatus is simple in mechanism and easy to transport. Dye experiment is possible in the surfe zone where a boat cannot enter. It is impossible, however, to raise the balloon in strong wind or sea breeze. Typical results of the dye diffusion experiment with the apparatus are given. (author)

  14. Tackling the Issue of High Postoperative Pacemaker Implantation Rates in Sutureless Aortic Valve Replacement: Should Balloon Inflation be Removed from the Implantation Method of the Perceval Prosthesis?

    Science.gov (United States)

    Charles Blouin, Mathieu; Bouhout, Ismail; Demers, Philippe; Carrier, Michel; Perrault, Louis; Lamarche, Yoan; El-Hamamsy, Ismail; Bouchard, Denis

    2017-05-01

    Sutureless aortic valve replacement (AVR) is an emerging alternative to standard AVR in elderly and high-risk patients. This procedure is associated with a high rate of postoperative permanent pacemaker implantation (PPI). The study aim was to assess the impact on the rate of PPI of implanting the Perceval prosthesis without using balloon inflation. A total of 159 patients who underwent sutureless AVR using the Perceval prosthesis was included. Balloon inflation was used in 132 patients (Balloon group) and not used in the remaining 27 (No-Balloon group). Clinical, echocardiographic and electrocardiographic outcomes were assessed. There was no significant difference in PPI rate between the two groups (26% for Balloon group versus 22% in No-Balloon group; p = 0.700). Balloon inflation had no significant impact on the incidence of paravalvular leaks (p = 0.839), or on the need to return to cardiopulmonary bypass (CPB) intraoperatively due to paravalvular leak or unsatisfactory deployment (p >0.999). Mean and peak transaortic pressure gradients were similar between the two groups (p = 0.417 and p = 0.522, respectively). Cross-clamp and CPB times were shorter in the No-Balloon group (49.6 ± 15.9 min versus 61.1 ± 25.6 min and 64.1 ± 26.3 min versus 79.6 ± 35.4 min, respectively; p = 0.027 and p = 0.012, respectively). The two groups had similar postoperative PPI rates. Implanting the Perceval prosthesis without balloon inflation is safe and had no impact on paravalvular leaks, intraoperative complications or hemodynamic results. Reductions in aortic cross-clamp time and CPB time were observed when the balloon was not used.

  15. Unconventional ballooning structures for toroidal drift waves

    International Nuclear Information System (INIS)

    Xie, Hua-sheng; Xiao, Yong

    2015-01-01

    With strong gradients in the pedestal of high confinement mode (H-mode) fusion plasmas, gyrokinetic simulations are carried out for the trapped electron and ion temperature gradient modes. A broad class of unconventional mode structures is found to localize at arbitrary poloidal positions or with multiple peaks. It is found that these unconventional ballooning structures are associated with different eigen states for the most unstable mode. At weak gradient (low confinement mode or L-mode), the most unstable mode is usually in the ground eigen state, which corresponds to a conventional ballooning mode structure peaking in the outboard mid-plane of tokamaks. However, at strong gradient (H-mode), the most unstable mode is usually not the ground eigen state and the ballooning mode structure becomes unconventional. This result implies that the pedestal of H-mode could have better confinement than L-mode

  16. From the glass door to the glass ceiling: An analysis of the gender wage gap by age groups

    OpenAIRE

    Elena Dalla Chiara; Eleonora Matteazzi; Ilaria Petrarca

    2014-01-01

    Using 2009 EU-SILC data for France, Italy, the Netherlands and the United Kingdom, we decompose the gender wage gap for prime age workers. We adopt an age group approach to identify when and how the glass door and the glass ceiling effects arise and their persistency over time. The empirical results verify that the raw gender wage gap increases with age. In all considered countries, the glass ceiling effect is completely realized by the age of 30 and increases over time. French, Italian and B...

  17. Door and cabinet recognition using convolutional neural nets and real-time method fusion for handle detection and grasping

    DEFF Research Database (Denmark)

    Maurin, Adrian Llopart; Ravn, Ole; Andersen, Nils Axel

    2017-01-01

    In this paper we present a new method that robustly identifies doors, cabinets and their respective handles, with special emphasis on extracting useful features from handles to be then manipulated. The novelty of this system relies on the combination of a Convolutional Neural Net (CNN), as a form...

  18. A cooled water-irrigated intraesophageal balloon to prevent thermal injury during cardiac ablation: experimental study based on an agar phantom

    International Nuclear Information System (INIS)

    Lequerica, Juan L; Berjano, Enrique J; Herrero, Maria; Melecio, Lemuel; Hornero, Fernando

    2008-01-01

    A great deal of current research is directed to finding a way to minimize thermal injury in the esophagus during radiofrequency catheter ablation of the atrium. A recent clinical study employing a cooling intraesophageal balloon reported a reduction of the temperature in the esophageal lumen. However, it could not be determined whether the deeper muscular layer of the esophagus was cooled enough to prevent injury. We built a model based on an agar phantom in order to experimentally study the thermal behavior of this balloon by measuring the temperature not only on the balloon, but also at a hypothetical point between the esophageal lumen and myocardium (2 mm distant). Controlled temperature (55 0 C) ablations were conducted for 120 s. The results showed that (1) the cooling balloon provides a reduction in the final temperature reached, both on the balloon surface and at a distance of 2 mm; (2) coolant temperature has a significant effect on the temperature measured at 2 mm from the esophageal lumen (it has a less effect on the temperature measured on the balloon surface) and (3) the pre-cooling period has a significant effect on the temperature measured on the balloon surface (the effect on the temperature measured 2 mm away is small). The results were in good agreement with those obtained in a previous clinical study. The study suggests that the cooling balloon gives thermal protection to the esophagus when a minimum pre-cooling period of 2 min is programmed at a coolant temperature of 5 deg. C or less. (note)

  19. Using Face Recognition in the Automatic Door Access Control in a Secured Room

    Directory of Open Access Journals (Sweden)

    Gheorghe Gilca

    2017-06-01

    Full Text Available The aim of this paper is to help users improve the door security of sensitive locations by using face detection and recognition. This paper is comprised mainly of three subsystems: face detection, face recognition and automatic door access control. The door will open automatically for the known person due to the command of the microcontroller.

  20. Blood pressure normalization post-jugular venous balloon angioplasty.

    Science.gov (United States)

    Sternberg, Zohara; Grewal, Prabhjot; Cen, Steven; DeBarge-Igoe, Frances; Yu, Jinhee; Arata, Michael

    2015-05-01

    This study is the first in a series investigating the relationship between autonomic nervous system dysfunction and chronic cerebrospinal venous insufficiency in multiple sclerosis patients. We screened patients for the combined presence of the narrowing of the internal jugular veins and symptoms of autonomic nervous system dysfunction (fatigue, cognitive dysfunction, sleeping disorders, headache, thermal intolerance, bowel/bladder dysfunction) and determined systolic and diastolic blood pressure responses to balloon angioplasty. The criteria for eligibility for balloon angioplasty intervention included ≥ 50% narrowing in one or both internal jugular veins, as determined by the magnetic resonance venography, and ≥ 3 clinical symptoms of autonomic nervous system dysfunction. Blood pressure was measured at baseline and post-balloon angioplasty. Among patients who were screened, 91% were identified as having internal jugular veins narrowing (with obstructing lesions) combined with the presence of three or more symptoms of autonomic nervous system dysfunction. Balloon angioplasty reduced the average systolic and diastolic blood pressure. However, blood pressure categorization showed a biphasic response to balloon angioplasty. The procedure increased blood pressure in multiple sclerosis patients who presented with baseline blood pressure within lower limits of normal ranges (systolic ≤ 105 mmHg, diastolic ≤ 70 mmHg) but decreased blood pressure in patients with baseline blood pressure above normal ranges (systolic ≥ 130 mmHg, diastolic ≥ 80 mmHg). In addition, gender differences in baseline blood pressure subcategories were observed. The coexistence of internal jugular veins narrowing and symptoms of autonomic nervous system dysfunction suggests that the two phenomena may be related. Balloon angioplasty corrects blood pressure deviation in multiple sclerosis patients undergoing internal jugular vein dilation. Further studies should investigate the

  1. Hot air balloons fill gap in atmospheric and sensing platforms

    Science.gov (United States)

    Watson, Steven M.; Price, Russ

    Eric Edgerton was having a problem he could not solve: how to noninvasively collect in situ incinerator plume data. So he called in the Air Force and learned about its Atmospheric and Sensor Test Platform program; its platform is a manned hot air balloon. Many investigators are discovering the advantages of hot air balloons as stable, inexpensive platforms for performing in situ atmospheric measurements. Some are also using remote sensing capabilities on the balloon platforms.

  2. Ballooning-mirror instability and internally driven Pc 4--5 wave events

    International Nuclear Information System (INIS)

    Cheng, C.Z.; Qian, Q.; Takahashi, K.; Lui, A.T.Y.

    1994-03-01

    A kinetic-MHD field-aligned eigenmode stability analysis of low frequency ballooning-mirror instabilities has been performed for anisotropic pressure plasma sin the magnetosphere. The ballooning mode is mainly a transverse wave driven unstable by pressure gradient in the bad curvature region. The mirror mode with a dominant compressional magnetic field perturbation is excited when the product of plasma beta and pressure anisotropy (P perpendicular /P parallel > 1) is large. From the AMPTE/CCE particle and magnetic field data observed during Pc 4--5 wave events the authors compute the ballooning-mirror instability parameters and perform a correlation study with the theoretical instability threshold. They find that compressional Pc 5 waves approximately satisfy the ballooning-mirror instability condition, and transverse Pc 4--5 waves are probably related to resonant ballooning instabilities with small pressure anisotropy

  3. Detection of Artificially Generated Seismic Signals Using Balloon-Borne Infrasound Sensors

    Science.gov (United States)

    Krishnamoorthy, Siddharth; Komjathy, Attila; Pauken, Michael T.; Cutts, James A.; Garcia, Raphael F.; Mimoun, David; Cadu, Alexandre; Sournac, Anthony; Jackson, Jennifer M.; Lai, Voon Hui; Bowman, Daniel C.

    2018-04-01

    We conducted an experiment in Pahrump, Nevada, in June 2017, where artificial seismic signals were created using a seismic hammer, and the possibility of detecting them from their acoustic signature was examined. In this work, we analyze the pressure signals recorded by highly sensitive barometers deployed on the ground and on tethers suspended from balloons. Our signal processing results show that wind noise experienced by a barometer on a free-flying balloon is lower compared to one on a moored balloon. This has never been experimentally demonstrated in the lower troposphere. While seismoacoustic signals were not recorded on the hot air balloon platform owing to operational challenges, we demonstrate the detection of seismoacoustic signals on our moored balloon platform. Our results have important implications for performing seismology in harsh surface environments such as Venus through atmospheric remote sensing.

  4. Opening Doors, Hearts and Minds

    Science.gov (United States)

    Foster, Andrea

    2007-01-01

    A panel discussion, "Opening Doors, Hearts and Minds," was hosted at the 2006 annual COEO conference. Four dedicated Torontonians shared how they interpret outdoor environmental education and environmental education in what they do and offered suggestions as to how their work might be integrated in diverse urban communities. Tafari…

  5. Montgolfiere balloon missions from Mars and Titan

    Science.gov (United States)

    Jones, Jack A.

    2005-01-01

    Montgolfieres, which are balloons that are filled with heated ambient atmospheric gas, appear promising for the exploration of Mars as well as of Saturn's moon, Titan. On Earth, Montgolfieres are also known as 'hot air balloons'. Commercial versions are typically heated by burning propane, although a number of radiant and solar-heated Montgolfieres have been flown on earth by CNES.

  6. Dose Reduction Study in Vaginal Balloon Packing Filled With Contrast for HDR Brachytherapy Treatment

    International Nuclear Information System (INIS)

    Saini, Amarjit S.; Zhang, Geoffrey G.; Finkelstein, Steven E.; Biagioli, Matthew C.

    2011-01-01

    Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken with each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 ± 0.002 for contrast/saline solution and 0.808 ± 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 ± 0.010 and 0.781 ± 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.

  7. Door-to-door survey of major neurological disorders (project in Al Quseir City, Red Sea Governorate, Egypt

    Directory of Open Access Journals (Sweden)

    El Tallawy HN

    2013-05-01

    Full Text Available Hamdy NA El Tallawy,1 Wafaa MA Farghaly,1 Tarek A Rageh,1 Ghaydaa A Shehata,1 Reda Badry,1 Nabil A Metwally,2 Esam A El Moselhy,2 Mahmoud Hassan,2 Mohamed A Sayed,3 Ahmed A Waris,1 Yaser Hamed,2 Islam Shaaban,2 Mohamed A Hamed,1 Mahmoud Raafat Kandil11Department of Neurology, Faculty of Medicine, Assiut University, Assiut, Egypt; 2Department of Neurology and Public Health, Faculty of Medicine, Al-Azhar University (Assiut branch, Assiut, Egypt; 3Department of Neurology, Faculty of Medicine, Sohag University, Sohag, EgyptAbstract: A door-to-door survey, including every household, was conducted for all inhabitants of Al Quseir City (33,283, Red Sea Governorate, Egypt by three specialists of neurology as well as nine senior staff members of neurology and 15 female social workers to assess the epidemiology of major neurological disorders. Over six phases, from July 1, 2009 to January 31, 2012, screening of all eligible people in the population was carried out, by which case ascertainment of all major neurological disorders included in the study was done according to the accepted definitions and diagnostic criteria of the World Health Organization. The order of frequency of prevalence of the studied neurological disorders was dementia (3.83% for those aged > 60 years, migraine (2.8% for those aged > 8 years, stroke (6.2/1000 for those aged > 20 years, epilepsy (5.5/1000, Parkinson’s disease (452.1/100,000 for those aged > 40 years, cerebral palsy (3.6/1000 among children 37 years, chorea (21.03/100,000, athetosis (15/100,000, and multiple sclerosis (13.74/100,000. The incidence rates of stroke, epilepsy, and Bell’s palsy were 181/100,000, 48/100,000, and 98.9/100,000 per year, respectively.Keywords: prevalence, incidence, neurological disorders

  8. Titan Exploration Using a Radioisotopically-Heated Montgolfiere Balloon

    Science.gov (United States)

    Elliott, John O.; Reh, Kim; Spilker, Tom

    2007-01-01

    This paper describes results of a recent Titan exploration mission study; one which includes an aerial vehicle in the form of a hot air balloon, or montgolfiere. Unlike terrestrial montgolfieres which require burning fuel, the dual use of MMRTGs to provide a continuous source of heat as well as electrical power would give the balloon an inherent ability to float for a very long time in the atmosphere of Titan. It would ride with the easterly winds at a cruising altitude of about 10,000 km, occasionally changing altitude to take advantage of possible reverse wind directions and even descending to the surface to physically sample sites of interest. Seasonal and tidal north-south winds would allow the mission to explore different latitudes, which Cassini data have shown to be amazingly diverse in geologic nature. Communication from the aerial vehicle would be relayed through an accompanying orbiter spacecraft, as well as transmitted directly to Earth, providing the potential for data return from Titan's surface equivalent to that provided by many comparable orbiter missions at much closer destinations.

  9. Maillard-reactie door model beheersbaar

    NARCIS (Netherlands)

    Roost, van M.

    2006-01-01

    Gewenste en ongewenste bruinkleuring van levensmiddelen door een Maillard-reactie is vaak lastig te beheersen. Wageningse onderzoekers ontwikkelden een simulatiemodel, waarmee producentenmeer inzicht krijgen in de Maillard-reactie, en zo ook de kleur van het eindproduct beter kunnen beheersen

  10. Constant volume balloons measurements in the urban Marseille and Fos-Berre industrial ozone plumes during ESCOMPTE experiment

    Science.gov (United States)

    Bénech, Bruno; Ezcurra, Agustin; Lothon, Marie; Saïd, Frédérique; Campistron, Bernard; Lohou, Fabienne; Durand, Pierre

    ESCOMPTE programme aims at studying the emissions of primary pollutants in industrial and urban areas, their transport, diffusion and transformation in the atmosphere. This experiment, carried out in southeast France, can be used to validate and to improve meteorological and chemical mesoscale models. One major goal of this experiment was to follow the pollutant plumes, and to investigate its thermodynamic and physico-chemical time evolution. This was realized by means of constant volume balloons, located by global position satellite (GPS) and equipped with thermodynamic and ozone sensors, flying at constant density levels. During the two ESCOMPTE campaigns that took place in June and July 2000 and 2001, 40 balloons were launched, 17 of them equipped with ozone sensors during the day from 0800 to 1800 UTC. Balloons' altitudes flight levels ranged between 400 and 1200 m altitude with Mistral (northerly synoptic flow) and Sea Breeze (southerly breeze) conditions. The atmospheric boundary layer (ABL) topography of the experimental domain is complex and varies strongly from day to day. Its depth presents a large gradient from the sea coast to the north part of the ESCOMPTE domain, and also more complex variability within the domain. The balloons' trajectories describe the evolution of the pollutant plume emitted from the industrial area of Fos-Berre or from the Marseille urban area. Constant volume balloons give a good description of the trajectories of these two plumes. The balloons, which fly at an isopicnic level, cross different atmospheric layers chiefly depending on the ABL height in relation with the constant volume balloons flight level. Thus, each balloon flight is decomposed into different segments that correspond to the same atmospheric layer. In each segment, the ozone content variation is analyzed in relation to other thermodynamical parameters measured by the balloon and mainly to the vapor mixing ratio content. During ESCOMPTE campaign, the mean linear

  11. Double balloon esophageal catheter for diagnosis of tracheo-esophageal fistula

    International Nuclear Information System (INIS)

    Kiyan, Guersu; Dagli, Tolga E.; Tugtepe, Halil; Kodalli, Nihat

    2003-01-01

    Congenital H-type and recurrent tracheo-esophageal fistulas (TEF) are always difficult to diagnose. For a more accurate diagnosis we designed a new double balloon catheter, which is a modification of esophageal dilatation balloon. The catheter has two balloons to occlude the esophagus proximal and distal to the fistula. The fistula can be identified by passing of the contrast material to the tracheal tree, which was injected into the esophageal segment between the inflated balloons. To prove the efficiency of this catheter, a TEF was created surgically in a New Zealand rabbit. On the postoperative fourteenth day the catheter was tried and the fistula could be visualized easily by injecting the contrast material. We think this technique may be of use in the diagnosis of TEF in children. (orig.)

  12. Median nail dystrophy involving the thumb nail

    Directory of Open Access Journals (Sweden)

    Rahulkrishna Kota

    2016-01-01

    Full Text Available Median canaliform dystrophy of Heller is a rare entity characterized by a midline or a paramedian ridge or split and canal formation in nail plate of one or both the thumb nails. It is an acquired condition resulting from a temporary defect in the matrix that interferes with nail formation. Habitual picking of the nail base may be responsible for some cases. Histopathology classically shows parakeratosis, accumulation of melanin within and between the nail bed keratinocytes. Treatment of median nail dystrophy includes injectable triamcinalone acetonide, topical 0.1% tacrolimus, and tazarotene 0.05%, which is many a times challenging for a dermatologist. Psychiatric opinion should be taken when associated with the depressive, obsessive-compulsive, or impulse-control disorder. We report a case of 19-year-old male diagnosed as median nail dystrophy.

  13. 78 FR 9785 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances

    Science.gov (United States)

    2013-02-12

    ... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... airworthiness directive (AD) for certain Lindstrand Hot Air Balloons Ltd female ACME threaded hose connectors...., Washington, DC 20590. For service information identified in this AD, contact Lindstrand Hot Air Balloons Ltd...

  14. Second-generation endometrial ablation technologies: the hot liquid balloons.

    Science.gov (United States)

    Vilos, George A; Edris, Fawaz

    2007-12-01

    Hysteroscopic endometrial ablation (HEA) was introduced in the 1980s to treat menorrhagia. Its use required additional training, surgical expertise and specialized equipment to minimize emergent complications such as uterine perforations, thermal injuries and excessive fluid absorption. To overcome these difficulties and concerns, thermal balloon endometrial ablation (TBEA) was introduced in the 1990s. Four hot liquid balloons have been introduced into clinical practice. All systems consist of a catheter (4-10mm diameter), a silicone balloon and a control unit. Liquids used to inflate the balloons include internally heated dextrose in water (ThermaChoice, 87 degrees C), and externally heated glycine (Cavaterm, 78 degrees C), saline (Menotreat, 85 degrees ) and glycerine (Thermablate, 173 degrees C). All balloons require pressurization from 160 to 240 mmHg for treatment cycles of 2 to 10 minutes. Prior to TBEA, preoperative endometrial thinning, including suction curettage, is optional. Several RCTs and cohort studies indicate that the advantages of TBEA include portability, ease of use and short learning curve. In addition, small diameter catheters requiring minimal cervical dilatation (5-7 mm) and short duration of treatment cycles (2-8 min) allow treatment under minimal analgesia/anesthesia requirements in a clinic setting. Following TBEA serious adverse events, including thermal injuries to viscera have been experienced. To minimize such injuries some surgeons advocate the use of routine post-dilatation hysteroscopy and/or ultrasonography to confirm correct intrauterine placement of the balloon prior to initiating the treatment cycle. After 10 years of clinical practice, TBEA is thought to be the preferred first-line surgical treatment of menorrhagia in appropriately selected candidates. Economic modeling also suggested that TBEA may be more cost-effective than HEA.

  15. MHD Ballooning Instability in the Plasma Sheet

    International Nuclear Information System (INIS)

    Cheng, C.Z.; Zaharia, S.

    2003-01-01

    Based on the ideal-MHD model the stability of ballooning modes is investigated by employing realistic 3D magnetospheric equilibria, in particular for the substorm growth phase. Previous MHD ballooning stability calculations making use of approximations on the plasma compressibility can give rise to erroneous conclusions. Our results show that without making approximations on the plasma compressibility the MHD ballooning modes are unstable for the entire plasma sheet where beta (sub)eq is greater than or equal to 1, and the most unstable modes are located in the strong cross-tail current sheet region in the near-Earth plasma sheet, which maps to the initial brightening location of the breakup arc in the ionosphere. However, the MHD beq threshold is too low in comparison with observations by AMPTE/CCE at X = -(8 - 9)R(sub)E, which show that a low-frequency instability is excited only when beq increases over 50. The difficulty is mitigated by considering the kinetic effects of ion gyrorad ii and trapped electron dynamics, which can greatly increase the stabilizing effects of field line tension and thus enhance the beta(sub)eq threshold [Cheng and Lui, 1998]. The consequence is to reduce the equatorial region of the unstable ballooning modes to the strong cross-tail current sheet region where the free energy associated with the plasma pressure gradient and magnetic field curvature is maximum

  16. Liquid- and air-filled catheters without balloon as an alternative to the air-filled balloon catheter for measurement of esophageal pressure.

    Science.gov (United States)

    Beda, Alessandro; Güldner, Andreas; Carvalho, Alysson R; Zin, Walter Araujo; Carvalho, Nadja C; Huhle, Robert; Giannella-Neto, Antonio; Koch, Thea; de Abreu, Marcelo Gama

    2014-01-01

    Measuring esophageal pressure (Pes) using an air-filled balloon catheter (BC) is the common approach to estimate pleural pressure and related parameters. However, Pes is not routinely measured in mechanically ventilated patients, partly due to technical and practical limitations and difficulties. This study aimed at comparing the conventional BC with two alternative methods for Pes measurement, liquid-filled and air-filled catheters without balloon (LFC and AFC), during mechanical ventilation with and without spontaneous breathing activity. Seven female juvenile pigs (32-42 kg) were anesthetized, orotracheally intubated, and a bundle of an AFC, LFC, and BC was inserted in the esophagus. Controlled and assisted mechanical ventilation were applied with positive end-expiratory pressures of 5 and 15 cmH2O, and driving pressures of 10 and 20 cmH2O, in supine and lateral decubitus. Cardiogenic noise in BC tracings was much larger (up to 25% of total power of Pes signal) than in AFC and LFC (<3%). Lung and chest wall elastance, pressure-time product, inspiratory work of breathing, inspiratory change and end-expiratory value of transpulmonary pressure were estimated. The three catheters allowed detecting similar changes in these parameters between different ventilation settings. However, a non-negligible and significant bias between estimates from BC and those from AFC and LFC was observed in several instances. In anesthetized and mechanically ventilated pigs, the three catheters are equivalent when the aim is to detect changes in Pes and related parameters between different conditions, but possibly not when the absolute value of the estimated parameters is of paramount importance. Due to a better signal-to-noise ratio, and considering its practical advantages in terms of easier calibration and simpler acquisition setup, LFC may prove interesting for clinical use.

  17. Liquid- and air-filled catheters without balloon as an alternative to the air-filled balloon catheter for measurement of esophageal pressure.

    Directory of Open Access Journals (Sweden)

    Alessandro Beda

    Full Text Available BACKGROUND: Measuring esophageal pressure (Pes using an air-filled balloon catheter (BC is the common approach to estimate pleural pressure and related parameters. However, Pes is not routinely measured in mechanically ventilated patients, partly due to technical and practical limitations and difficulties. This study aimed at comparing the conventional BC with two alternative methods for Pes measurement, liquid-filled and air-filled catheters without balloon (LFC and AFC, during mechanical ventilation with and without spontaneous breathing activity. Seven female juvenile pigs (32-42 kg were anesthetized, orotracheally intubated, and a bundle of an AFC, LFC, and BC was inserted in the esophagus. Controlled and assisted mechanical ventilation were applied with positive end-expiratory pressures of 5 and 15 cmH2O, and driving pressures of 10 and 20 cmH2O, in supine and lateral decubitus. MAIN RESULTS: Cardiogenic noise in BC tracings was much larger (up to 25% of total power of Pes signal than in AFC and LFC (<3%. Lung and chest wall elastance, pressure-time product, inspiratory work of breathing, inspiratory change and end-expiratory value of transpulmonary pressure were estimated. The three catheters allowed detecting similar changes in these parameters between different ventilation settings. However, a non-negligible and significant bias between estimates from BC and those from AFC and LFC was observed in several instances. CONCLUSIONS: In anesthetized and mechanically ventilated pigs, the three catheters are equivalent when the aim is to detect changes in Pes and related parameters between different conditions, but possibly not when the absolute value of the estimated parameters is of paramount importance. Due to a better signal-to-noise ratio, and considering its practical advantages in terms of easier calibration and simpler acquisition setup, LFC may prove interesting for clinical use.

  18. The effect of pressure anisotropy on ballooning modes in tokamak plasmas

    Science.gov (United States)

    Johnston, A.; Hole, M. J.; Qu, Z. S.; Hezaveh, H.

    2018-06-01

    Edge Localised Modes are thought to be caused by a spectrum of magnetohydrodynamic instabilities, including the ballooning mode. While ballooning modes have been studied extensively both theoretically and experimentally, the focus of the vast majority of this research has been on isotropic plasmas. The prevalence of pressure anisotropy in modern tokamaks thus motivates further study of these modes. This paper presents a numerical analysis of ballooning modes in anisotropic equilibria. The investigation was conducted using the newly-developed codes HELENA+ATF and MISHKA-A, which adds anisotropic physics to equilibria and stability analysis. We have examined the impact of anisotropy on the stability of an n = 30 ballooning mode, confirming results conform to previous calculations in the isotropic limit. Growth rates of ballooning modes in equilibria with different levels of anisotropy were then calculated using the stability code MISHKA-A. The key finding was that the level of anisotropy had a significant impact on ballooning mode growth rates. For {T}\\perp > {T}| | , typical of ICRH heating, the growth rate increases, while for {T}\\perp < {T}| | , typical of neutral beam heating, the growth rate decreases.

  19. A stratospheric balloon experiment to test the Huygens atmospheric structure instrument (HASI)

    Science.gov (United States)

    Fulchignoni, M.; Aboudan, A.; Angrilli, F.; Antonello, M.; Bastianello, S.; Bettanini, C.; Bianchini, G.; Colombatti, G.; Ferri, F.; Flamini, E.; Gaborit, V.; Ghafoor, N.; Hathi, B.; Harri, A.-M.; Lehto, A.; Lion Stoppato, P. F.; Patel, M. R.; Zarnecki, J. C.

    2004-08-01

    We developed a series of balloon experiments parachuting a 1:1 scale mock-up of the Huygens probe from an altitude just over 30 km to simulate at planetary scale the final part of the descent of the probe through Titan's lower atmosphere. The terrestrial atmosphere represents a natural laboratory where most of the physical parameters meet quite well the bulk condition of Titan's environment, in terms of atmosphere composition, pressure and mean density ranges, though the temperature range will be far higher. The probe mock-up consists of spares of the HASI sensor packages, housekeeping sensors and other dedicated sensors, and also incorporates the Huygens Surface Science Package (SSP) Tilt sensor and a modified version of the Beagle 2 UV sensor, for a total of 77 acquired sensor channels, sampled during ascent, drift and descent phase. An integrated data acquisition and instrument control system, simulating the HASI data-processing unit (DPU), has been developed, based on PC architecture and soft-real-time application. Sensor channels were sampled at the nominal HASI data rates, with a maximum rate of 1 kHz. Software has been developed for data acquisition, onboard storage and telemetry transmission satisfying all requests for real-time monitoring, diagnostic and redundancy. The mock-up of the Huygens probe mission was successfully launched for the second time (first launch in summer 2001, see Gaborit et al., 2001) with a stratospheric balloon from the Italian Space Agency Base "Luigi Broglio" in Sicily on May 30, 2002, and recovered with all sensors still operational. The probe was lifted to an altitude of 32 km and released to perform a parachuted descent lasting 53 min, to simulate the Huygens mission at Titan. Preliminary aerodynamic study of the probe has focused upon the achievement of a descent velocity profile reproducing the expected profile of Huygens probe descent into Titan. We present here the results of this experiment discussing their relevance in

  20. HZETRN radiation transport validation using balloon-based experimental data

    Science.gov (United States)

    Warner, James E.; Norman, Ryan B.; Blattnig, Steve R.

    2018-05-01

    The deterministic radiation transport code HZETRN (High charge (Z) and Energy TRaNsport) was developed by NASA to study the effects of cosmic radiation on astronauts and instrumentation shielded by various materials. This work presents an analysis of computed differential flux from HZETRN compared with measurement data from three balloon-based experiments over a range of atmospheric depths, particle types, and energies. Model uncertainties were quantified using an interval-based validation metric that takes into account measurement uncertainty both in the flux and the energy at which it was measured. Average uncertainty metrics were computed for the entire dataset as well as subsets of the measurements (by experiment, particle type, energy, etc.) to reveal any specific trends of systematic over- or under-prediction by HZETRN. The distribution of individual model uncertainties was also investigated to study the range and dispersion of errors beyond just single scalar and interval metrics. The differential fluxes from HZETRN were generally well-correlated with balloon-based measurements; the median relative model difference across the entire dataset was determined to be 30%. The distribution of model uncertainties, however, revealed that the range of errors was relatively broad, with approximately 30% of the uncertainties exceeding ± 40%. The distribution also indicated that HZETRN systematically under-predicts the measurement dataset as a whole, with approximately 80% of the relative uncertainties having negative values. Instances of systematic bias for subsets of the data were also observed, including a significant underestimation of alpha particles and protons for energies below 2.5 GeV/u. Muons were found to be systematically over-predicted at atmospheric depths deeper than 50 g/cm2 but under-predicted for shallower depths. Furthermore, a systematic under-prediction of alpha particles and protons was observed below the geomagnetic cutoff, suggesting that

  1. Framing alters risk-taking behavior on a modified Balloon Analogue Risk Task (BART) in a sex-specific manner.

    Science.gov (United States)

    Gabriel, Kara I; Williamson, Ashley

    2010-12-01

    Framing uncertain scenarios to emphasize potential positive or negative elements influences decision making and behavior. The current experiment investigated sex differences in framing effects on risk-taking propensity in a modified version of the Balloon Analogue Risk Task (BART). Male and female undergraduates completed questionnaires on sensation seeking, impulsiveness, and risk and benefit perception prior to viewing one of three framing conditions for the BART: (1) positively-framed instructions emphasizing the ability to earn money if balloons were inflated to large size; (2) negatively framed instructions emphasizing the possibility that money could be lost if balloons were inflated to bursting; and (3) completely framed instructions noting both possible outcomes. Results revealed correlations between BART performance and impulsiveness for both sexes. Compared to positive and complete framing, negatively framed instructions decreased balloon inflation time in women but not men, indicating sex differences in response to treatments designed to alter risk-taking behavior.

  2. Test ventilation with smoke, bubbles, and balloons

    International Nuclear Information System (INIS)

    Pickering, P.L.; Cucchiara, A.L.; McAtee, J.L.; Gonzales, M.

    1987-01-01

    The behavior of smoke, bubbles, and helium-filled balloons was videotaped to demonstrate the mixing of air in the plutonium chemistry laboratories, a plutonium facility. The air-distribution patterns, as indicated by each method, were compared. Helium-filled balloons proved more useful than bubbles or smoke in the visualization of airflow patterns. The replay of various segments of the videotape proved useful in evaluating the different techniques and in identifying airflow trends responsible for air mixing. 6 refs

  3. Balloon dacryocystoplasty: Incomplete versus complete obstruction of the nasolacrimal system

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Lee, Sang Hoon; Han, Young Min; Chung, Gyung Ho; Kim, Chong Soo; Choi, Ki Chul; Song, Ho Young

    1993-01-01

    Balloon dilatation of nasolacrimal drainage apparatus was attempted for the treatment of stenoses or obstructures of the nasolacrimal system in 49 eyes of 41 consecutive patients with complete obstructions and 16 eyes of 14 patients with incomplete obstructions. These two groups were compared with regards to the effectiveness of balloon dacryocystoplasty. All patients suffered from severe epiphora had already undergone multiple probings. A 0.018 inch hair or ball guide wire was introduced through the superior punctum into the inferior meatus of the nasal cavity and pulled out through the nasal aperture using a hemostat under nasal endoscopy. A deflated angiography balloon catheter was then introduced in a retrograde direction and dilated under fluoroscopic control. No major complications occurred in any of the patients. At 7 days after balloon dilatation, 25 of 49 eyes with complete obstruction demonstrated improvement in epiphora (initial success rate: 51.0%) and among them 17 eyes showed complete resolution of symptoms. Reocclusion occurred in 12 of the 25 eyes with initial improvement at the 2 months follow up. For the 16 eyes with incomplete obstruction, and improvement of epiphora was attained in 11 eyes (initial success rate 68.8%): 5 of these eyes showed complete resolution of epiphora, and 3 was failed to maintain initial improvement at the 2 month follow up. Although this study demonstrate that results of balloon dacryocystoplasty are not encouraging because of the high failure and recurrence rate, balloon dacryocystoplasty is a simple and safe nonsurgical technique that can be used to treat for obstructions of the nasolacrimal system. In addition, balloon dacryocystoplasty shows better results in incomplete obstruction than in complete obstruction than complete obstruction of the nasolacrimal system

  4. Design And Implementation Of A Door Locking System Using Android App

    Directory of Open Access Journals (Sweden)

    Agbo David O.

    2017-08-01

    Full Text Available The Android Operating System finds wide use in smart phones and tablets and is thus suitable for home controllers. This project presents a smart home controller that uses the Bluetooth in an Android device to control the operation of an automated security door system. The software was designed using an Android app that generates a password that is recognized by the Bluetooth to control the opening and closing of the door located at some distance from the user. The Bluetooth module that is installed on the door receives the commands from the android phone and passes these commands to the microcontroller that controls the opening and closing of the door. The design was simulated in Proteus integrated development environment after which the hardware was built on experimental boards. The performance of the system agrees excellently with its conception. The system can be used in various situations where access to an enclosure need to be secured

  5. The UK sounding rocket and balloon programme

    International Nuclear Information System (INIS)

    Delury, J.T.

    1980-01-01

    The UK civil science balloon and rocket programmes for 1979/80/81 are summarised and the areas of scientific interest for the period 1981/85 mentioned. In the main the facilities available are 10 in number balloons up to 40 m cu ft launched from USA or Australia and up to 10 in number 7 1/2'' diameter Petrel rockets. This paper outlines the 1979 and 1980 programmes and explains the longer term plans covering the next 5 years. (Auth.)

  6. A new TDRSS Compatible Transceiver for Long Duration HIgh Altitude Scientific Balloon Missions

    Science.gov (United States)

    Stilwell, B.; Siemon, M.

    High altitude scientific balloons have been used for many years to provide scientists with access to near space at a fraction of the cost of satellite based or sounding rocket experiments. In recent years, these balloons have been successfully used for long duration missions of up to several weeks. Longer missions with durations of up to 100 days (Ultra-Long) are on the drawing board. An enabling technology for the growth of the scientific balloon missions is the use of the NASA Tracking and Data Relay Satellite System (TDRSS) for telemetering the health, status, position and payload science data to mission operations personnel. The TDRSS system provides global coverage by relaying the data through geostationary relay satellites to a single ground station in White Sands New Mexico. Data passes from the White Sands station to the user via commercial telecommunications services including the Internet. A forward command link can also be established to the balloon for real- time command and control. Early TDRSS communications equipment used by the National Scientific Balloon Facility was either unreliable or too expensive. The equipment must be a le tob endure the rigors of space flight including radiation exposure, high temperature extremes and the shock of landing and recovery. Since a payload may occasionally be lost, the cost of the TDRSS communications gear is a limiting factor in the number of missions that can be supported. Under sponsorship of the NSBF, General Dynamics Decision Systems has developed a new TDRSS compatible transceiver that reduces the size, weight and cost to approximately one half that of the prior generation of hardware. This paper describes the long and ultra-long balloon missions and the role that TDRSS communications plays in mission success. The new transceiver design is described, along with its interfaces, performance characteristics, qualification and production status. The transceiver can also be used in other space, avionics or

  7. JUBA (Joint UAS-Balloon Activities) Final Campaign Report.

    Energy Technology Data Exchange (ETDEWEB)

    Dexheimer, Darielle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Apple, Monty [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Callow, Diane Schafer [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Longbottom, Casey Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Novick, David K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wilson, Christopher W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-02-01

    Using internal investment funds within Sandia National Laboratories’ (SNL) Division 6000, JUBA was a collaborative exercise between SNL Orgs. 6533 & 6913 (later 8863) to demonstrate simultaneous flights of tethered balloons and UAS on the North Slope of Alaska. JUBA UAS and tethered balloon flights were conducted within the Restricted Airspace associated with the ARM AMF3 site at Oliktok Point, Alaska. The Restricted Airspace occupies a 2 nautical mile radius around Oliktok Point. JUBA was conducted at the Sandia Arctic Site, which is approximately 2 km east-southeast of the AMF3. JUBA activities occurred from 08/08/17 – 08/10/17. Atmospheric measurements from tethered balloons can occur for a long duration, but offer limited spatial variation. Measurements from UAS could offer increased spatial variability.

  8. Numerical modeling of cold room's hinged door opening and closing processes

    Science.gov (United States)

    Carneiro, R.; Gaspar, P. D.; Silva, P. D.; Domingues, L. C.

    2016-06-01

    The need of rationalize energy consumption in agrifood industry has fasten the development of methodologies to improve the thermal and energy performances of cold rooms. This paper presents a three-dimensional (3D) transient Computational Fluid Dynamics (CFD) modelling of a cold room to evaluate the air infiltration rate through hinged doors. A species transport model is used for modelling the tracer gas concentration decay technique. Numerical predictions indicate that air temperature difference between spaces affects the air infiltration. For this case study, the infiltration rate increases 0.016 m3 s-1 per K of air temperature difference. The knowledge about the evolution of air infiltration during door opening/closing times allows to draw some conclusions about its influence on the air conditions inside the cold room, as well as to suggest best practices and simple technical improvements that can minimize air infiltration, and consequently improve thermal performance and energy consumption rationalization.

  9. The Tethered Balloon Current Generator - A space shuttle-tethered subsatellite for plasma studies and power generation

    Science.gov (United States)

    Williamson, P. R.; Banks, P. M.

    1976-01-01

    The objectives of the Tethered Balloon Current Generator experiment are to: (1) generate relatively large regions of thermalized, field-aligned currents, (2) produce controlled-amplitude Alfven waves, (3) study current-driven electrostatic plasma instabilities, and (4) generate substantial amounts of power or propulsion through the MHD interaction. A large balloon (a diameter of about 30 m) will be deployed with a conducting surface above the space shuttle at a distance of about 10 km. For a generally eastward directed orbit at an altitude near 400 km, the balloon, connected to the shuttle by a conducting wire, will be positive with respect to the shuttle, enabling it to collect electrons. At the same time, the shuttle will collect positive ions and, upon command, emit an electron beam to vary current flow in the system.

  10. High Altitude Infrasound Measurements using Balloon-Borne Arrays

    Science.gov (United States)

    Bowman, D. C.; Johnson, C. S.; Gupta, R. A.; Anderson, J.; Lees, J. M.; Drob, D. P.; Phillips, D.

    2015-12-01

    For the last fifty years, almost all infrasound sensors have been located on the Earth's surface. A few experiments consisting of microphones on poles and tethered aerostats comprise the remainder. Such surface and near-surface arrays likely do not capture the full diversity of acoustic signals in the atmosphere. Here, we describe results from a balloon mounted infrasound array that reached altitudes of up to 38 km (the middle stratosphere). The balloon drifted at the ambient wind speed, resulting in a near total reduction in wind noise. Signals consistent with tropospheric turbulence were detected. A spectral peak in the ocean microbarom range (0.12 - 0.35 Hz) was present on balloon-mounted sensors but not on static infrasound stations near the flight path. A strong 18 Hz signal, possibly related to building ventilation systems, was observed in the stratosphere. A wide variety of other narrow band acoustic signals of uncertain provenance were present throughout the flight, but were absent in simultaneous recordings from nearby ground stations. Similar phenomena were present in spectrograms from the last balloon infrasound campaign in the 1960s. Our results suggest that the infrasonic wave field in the stratosphere is very different from that which is readily detectable on surface stations. This has implications for modeling acoustic energy transfer between the lower and upper atmosphere as well as the detection of novel acoustic signals that never reach the ground. Our work provides valuable constraints on a proposed mission to detect earthquakes on Venus using balloon-borne infrasound sensors.

  11. ELMs and constraints on the H-mode pedestal: A model based on peeling-ballooning modes

    International Nuclear Information System (INIS)

    Snyder, P.B.; Ferron, J.R.; Wilson, H.R.

    2003-01-01

    We propose a model for Edge Localized Modes (ELMs) and pedestal constraint based upon theoretical analysis of instabilities which can limit the pedestal height and drive ELMs. The sharp pressure gradients, and resulting bootstrap current, in the pedestal region provide free energy to drive peeling and ballooning modes. The interaction of peeling-ballooning coupling, ballooning mode second stability, and finite-Larmor-radius effects results in coupled peeling-ballooning modes of intermediate wavelength generally being the limiting instability. A highly efficient new MHD code, ELITE, is used to calculate quantitative stability constraints on the pedestal, including con straits on the pedestal height. Because of the impact of collisionality on the bootstrap current, these pedestal constraints are dependant on the density and temperature separately, rather than simply on the pressure. A model of various ELM types is developed, and quantitatively compared to data. A number of observations agree with predictions, including ELM onset times, ELM depth and variation in pedestal height with collisionality and discharge shape. Stability analysis of series of model equilibria are used both o predict and interpret pedestal trends in existing experiments and to project pedestal constraints for future burning plasma tokamak designs. (author)

  12. A local network integrated into a balloon-borne apparatus

    Science.gov (United States)

    Imori, Masatosi; Ueda, Ikuo; Shimamura, Kotaro; Maeno, Tadashi; Murata, Takahiro; Sasaki, Makoto; Matsunaga, Hiroyuki; Matsumoto, Hiroshi; Shikaze, Yoshiaki; Anraku, Kazuaki; Matsui, Nagataka; Yamagami, Takamasa

    A local network is incorporated into an apparatus for a balloon-borne experiment. A balloon-borne system implemented in the apparatus is composed of subsystems interconnected through a local network, which introduces modular architecture into the system. The network decomposes the balloon-borne system into subsystems, which are similarly structured from the point of view that the systems is kept under the control of a ground station. The subsystem is functionally self-contained and electrically independent. A computer is integrated into a subsystem, keeping the subsystem under the control. An independent group of batteries, being dedicated to a subsystem, supplies the whole electricity of the subsystem. The subsystem could be turned on and off independently of the other subsystems. So communication among the subsystems needs to be based on such a protocol that could guarantee the independence of the individual subsystems. An Omninet protocol is employed to network the subsystems. A ground station sends commands to the balloon-borne system. The command is received and executed at the system, then results of the execution are returned to the ground station. Various commands are available so that the system borne on a balloon could be controlled and monitored remotely from the ground station. A subsystem responds to a specific group of commands. A command is received by a transceiver subsystem and then transferred through the network to the subsystem to which the command is addressed. Then the subsystem executes the command and returns results to the transceiver subsystem, where the results are telemetered to the ground station. The network enhances independence of the individual subsystems, which enables programs of the individual subsystems to be coded independently. Independence facilitates development and debugging of programs, improving the quality of the system borne on a balloon.

  13. Robotic weather balloon launchers spread in Alaska

    Science.gov (United States)

    Rosen, Julia

    2018-04-01

    Last week, things began stirring inside the truck-size box that sat among melting piles of snow at the airport in Fairbanks, Alaska. Before long, the roof of the box yawned open and a weather balloon took off into the sunny afternoon, instruments dangling. The entire launch was triggered with the touch of a button, 5 kilometers away at an office of the National Weather Service (NWS). The flight was smooth, just one of hundreds of twice-daily balloon launches around the world that radio back crucial data for weather forecasts. But most of those balloons are launched by people; the robotic launchers, which are rolling out across Alaska, are proving to be controversial. NWS says the autolaunchers will save money and free up staff to work on more pressing matters. But representatives of the employee union question their reliability, and say they will hasten the end of Alaska's remote weather offices, where forecasting duties and hours have already been slashed.

  14. To Enhance the Fire Resistance Performance of High-Speed Steel Roller Door with Water Film System

    Directory of Open Access Journals (Sweden)

    De-Hua Chung

    2015-01-01

    Full Text Available The structure of high-speed roller door with water film has improved in this study. The flameproof water film system is equipped with a water circulating device to reduce the water consumption of water film system. The water film is generated at the roller box of the high-speed roller door in this study. The heating test is done with the full-scale heating furnace. Both cases of the water film on unexposed surface and water film on exposed surface passed the fire resistance test based on ISO 834, proving that the high-speed roller door with water film system has 120A fire resistance period. The main findings indicate that the water film on exposed surface shows that as the amount of water film evaporated by high temperature inside the furnace must be greater than the evaporation capacity of water film on unexposed surface, the required water supply is 660 L more than the water film on unexposed surface.

  15. Scott Brothers Windows and Doors Information Sheet

    Science.gov (United States)

    Scott Brothers Windows and Doors (the Company) is located in Bridgeville, Pennsylvania. The settlement involves renovation activities conducted at property constructed prior to 1978, located in Pittsburgh, Pennsylvania.

  16. Blower door method in radon diagnostics

    International Nuclear Information System (INIS)

    Fronka, A.; Moucka, L.

    2004-01-01

    The idea of the radon transfer factor is commonly presented as the ratio of the building indoor radon concentration to the subsoil radon concentration. Ventilation and the pressure field over the whole building envelope, which varies in a time over a very wide range even in the same building, poses a major problem. Therefore a new approach based on the controlled conditions determining the soil air infiltration was developed. Radon in soil gas infiltrates into the building indoor environment particularly through cracks and other leakages in the structure providing the building contact with its subsoil. The infiltration is driven by the air pressure difference on the two sides of the structure. The pressure difference is caused by the stack effect and its value ranges from 1-2 Pa in family houses to some tens of Pa in higher buildings. Unfortunately, the pressure difference is very unstable under normal conditions, being affected by a host of parameters such as the height of the building, distribution and geometry of leakages, outdoor-indoor temperature difference, etc. Wind direction and velocity of the wind plays a major role. In our research the blower door method was applied in combination with a monitoring of the indoor radon concentration. The indoor-outdoor pressure difference and the pressure difference at the two sides of the screen shutter of the blower door fan are also measured. The blower door ensures a constant, evaluable air exchange rate. The fan power is regulated to provide a stable pressure difference within the range of roughly 5-100 Pa. This approach provides very well defined conditions allowing us to apply a constant ventilation-constant radon supply model. In such circumstances the dynamical changes of radon concentrations are very fast, and therefore a unique continual radon monitor was applied. The radon supply rate is evaluated from the radon steady state of the time course of radon concentration. The dependence of the radon supply rate on

  17. Retrieving Balloon Data in Flight

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's Ultra Long Duration Balloon (ULDB) program will soon make flights lasting up to 100 days. Some flights may generate high data rates and retrieving this data...

  18. Construction and testing of a blower-door assembly for regulation of air pressure within structures

    International Nuclear Information System (INIS)

    Steele, W.D.

    1987-09-01

    The Technical Measurements Center is evaluating several methods to decrease the time required to determine an annual average radon-daughter concentration in structures. One method involves stabilizing the air pressure within the structure at a constant pressure with reference to external atmospheric or soil-gas pressure. This report describes the construction and preliminary testing of a blower-door system to maintain a constant differential air pressure within a structure. The blower-door assembly includes a collapsible frame and a large fan to occlude a doorway, a damper with an actuator to control air flow, a controller to drive the damper actuator, and a pressure transducer to measure the differential pressure. Preliminary testing of the system indicates that pressure within the structure in the range of 1 to 20 Pascals can be held to within approximately +-1 Pa of the set point. Further testing of the blower-door system is planned to provide data on the applicability of this method to short-duration tests for annual average radon-daughter concentration estimates. 13 figs., 1 tab

  19. Koperemissies door drinkwaterleidingen (herziene editie)

    NARCIS (Netherlands)

    Verweij W; Mons MN; Aalbers JEM; Cruchten RGH van; LWD

    1996-01-01

    Ge-inventariseerd werd wat er bekend is over de fluxen van koper door (corrosie van) waterleidingen naar rioolwaterzuiveringsinstallaties (rwzi's), rwzi-slib en het oppervlaktewater. Gebleken is dat in 1993 (landelijk gemiddeld) 57% van de koperbelasting van rwzi's afkomstig is van

  20. Phase I/II Study Evaluating Early Tolerance in Breast Cancer Patients Undergoing Accelerated Partial Breast Irradiation Treated With the MammoSite Balloon Breast Brachytherapy Catheter Using a 2-Day Dose Schedule

    International Nuclear Information System (INIS)

    Wallace, Michelle; Martinez, Alvaro; Mitchell, Christina; Chen, Peter Y.; Ghilezan, Mihai; Benitez, Pamela; Brown, Eric; Vicini, Frank

    2010-01-01

    Purpose: Initial Phase I/II results using balloon brachytherapy to deliver accelerated partial breast irradiation (APBI) in 2 days in patients with early-stage breast cancer are presented. Materials and Methods: Between March 2004 and August 2007, 45 patients received adjuvant radiation therapy after lumpectomy with balloon brachytherapy in a Phase I/II trial delivering 2800 cGy in four fractions of 700 cGy. Toxicities were evaluated using the National Cancer Institute Common Toxicity Criteria for Adverse Events v3.0 scale and cosmesis was documented at ≥6 months. Results: The median age was 66 years (range, 48-83) and median skin spacing was 12 mm (range, 8-24). The median follow-up was 11.4 months (5.4-48 months) with 21 patients (47%) followed ≥1 year, 11 (24%) ≥2 years, and 7 (16%) ≥3 years. At <6 months (n = 45), Grade II toxicity rates were 9% radiation dermatitis, 13% breast pain, 2% edema, and 2% hyperpigmentation. Grade III breast pain was reported in 13% (n = 6). At ≥6 months (n = 43), Grade II toxicity rates were: 2% radiation dermatitis, 2% induration, and 2% hypopigmentation. Grade III breast pain was reported in 2%. Infection was 13% (n = 6) at <6 months and 5% (n = 2) at ≥6 months. Persistent seroma ≥6 months was 30% (n = 13). Fat necrosis developed in 4 cases (2 symptomatic). Rib fractures were seen in 4% (n = 2). Cosmesis was good/excellent in 96% of cases. Conclusions: Treatment with balloon brachytherapy using a 2-day dose schedule resulted acceptable rates of Grade II/III chronic toxicity rates and similar cosmetic results observed with a standard 5-day accelerated partial breast irradiation schedule.

  1. Star camera aspect system suitable for use in balloon experiments

    International Nuclear Information System (INIS)

    Hunter, S.D.; Baker, R.G.

    1985-01-01

    A balloon-borne experiment containing a star camera aspect system was designed, built, and flown. This system was designed to provide offset corrections to the magnetometer and inclinometer readings used to control an azimuth and elevation pointed experiment. The camera is controlled by a microprocessor, including commendable exposure and noise rejection threshold, as well as formatting the data for telemetry to the ground. As a background program, the microprocessor runs the aspect program to analyze a fraction of the pictures taken so that aspect information and offset corrections are available to the experiment in near real time. The analysis consists of pattern recognition of the star field with a star catalog in ROM memory and a least squares calculation. The performance of this system in ground based tests is described. It is part of the NASA/GSFC High Energy Gamma-Ray Balloon Instrument (2)

  2. Embolization of carotid-cavernous fistula using a silicone balloon and a tracker-catheter system

    International Nuclear Information System (INIS)

    Kim, Sun Yong; Cho, Kil Ho; Park, Bok Hwan

    1992-01-01

    With the recent introduction and development of the detachable balloon system, it has become the treatment of choice in the management of carotid cavernous fistulas(CCFs). But, since most delivery systems for embolization of CCF mainly depend on flow guidance for balloon delivery, in case of small fistula, pseudo aneurysm and arterialized venous collaterals, failure of balloon embolization can occur. To overcome these limitation, the authors designed and used a new versatile, steerable, and flow-guided detachable balloon system by using a Tracker catheter system with silicone or latex balloons. Using this maneuver, we could get successful fistula occlusion in 7 out of 8 patients (silicone balloon). But in one case, we had to occlude the internal carotid artery at the fistula site, proximal and distal cervical portions of the internal carotid artery. This balloon delivery system proved to provide high selectivity for fistula and relatively ease of handing

  3. Paraspinal arteriovenous malformation Onyx embolization via an Ascent balloon.

    Science.gov (United States)

    Martínez-Galdámez, Mario; Rodriguez-Arias, Carlos A; Utiel, Elena; Arreba, Emilio; Gonzalo, Miguel; Arenillas, Juan F

    2014-04-01

    Purely extradural lumbar spinal arteriovenous malformations (AVMs) are rare lesions that have diverse presentations and imaging features. The treatment of a symptomatic high flow paraspinal AVM with multiple feeders remains a challenge. We report the first use of an Ascent balloon (dual lumen balloon catheter) to deliver Onyx with excellent penetration to a paraspinal AVM.

  4. Modified jailed balloon technique for bifurcation lesions.

    Science.gov (United States)

    Saito, Shigeru; Shishido, Koki; Moriyama, Noriaki; Ochiai, Tomoki; Mizuno, Shingo; Yamanaka, Futoshi; Sugitatsu, Kazuya; Tobita, Kazuki; Matsumi, Junya; Tanaka, Yutaka; Murakami, Masato

    2017-12-04

    We propose a new systematic approach in bifurcation lesions, modified jailed balloon technique (M-JBT), and report the first clinical experience. Side branch occlusion brings with a serious complication and occurs in more than 7.0% of cases during bifurcation stenting. A jailed balloon (JB) is introduced into the side branch (SB), while a stent is placed in the main branch (MB) as crossing SB. The size of the JB is half of the MB stent size. While the proximal end of JB attaching to MB stent, both stent and JB are simultaneously inflated with same pressure. JB is removed and then guidewires are recrossed. Kissing balloon dilatation (KBD) and/or T and protrusion (TAP) stenting are applied as needed. Between February 2015 and February 2016, 233 patients (254 bifurcation lesions including 54 left main trunk disease) underwent percutaneous coronary intervention (PCI) using this technique. Procedure success was achieved in all cases. KBD was performed for 183 lesions and TAP stenting was employed for 31 lesions. Occlusion of SV was not observed in any of the patients. Bench test confirmed less deformity of MB stent in M-JBT compared with conventional-JBT. This is the first report for clinical experiences by using modified jailed balloon technique. This novel M-JBT is safe and effective in the preservation of SB patency during bifurcation stenting. © 2017 Wiley Periodicals, Inc.

  5. US Air Force Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Worksheets containing pilot balloon data computed from releases at Air Force stations in the western United States. Elevation and azimuth angles are used to compute...

  6. Thrombosed persistent median artery causing carpal tunnel syndrome associated with bifurcated median nerve: A case report

    International Nuclear Information System (INIS)

    Salter, M.; Sinha, N. R.; Szmigielski, W.

    2011-01-01

    Background: Carpal tunnel syndrome is a sporadically occurring abnormality due to compression of median nerve. It is exceedingly rare for it to be caused by thrombosis of persistent median artery. Case Report: A forty two year old female was referred for ultrasound examination due to ongoing wrist pain, not relived by pain killers and mild paraesthesia on the radial side of the hand. High resolution ultrasound and Doppler revealed a thrombosed persistent median artery and associated bifurcated median nerve. The thrombus resolved on treatment with anticoagulants. Conclusions: Ultrasound examination of the wrist when done for patients with carpal tunnel syndrome should preferably include looking for persistent median artery and its patency. (authors)

  7. Laparoscopic management of a small bowel obstruction secondary to Elipse intragastric balloon migration: A case report

    Directory of Open Access Journals (Sweden)

    Saud Al-Subaie

    Full Text Available Introduction: The Elipse™ intragastric balloon (IGB for weight loss is a swallowable capsule that is filled with 550 mL of fluid and resides in the stomach for four months before being excreted from the gastrointestinal tract. Although initial data showed that use of this device is safe and free from serious complications, we report for the first time the successful management of an Elipse™ IGB-related adverse event. Presentation of case: A 41-year-old woman presented to our emergency department following two days of abdominal pain, vomiting, and constipation. Her medical history included four caesarean sections and insertion of the Elipse™ IGB 16 weeks prior to presentation. The patient was vitally stable at presentation and abdominal examination revealed a mildly distended abdomen. Plain X-ray revealed a small bowel obstruction (SBO, and a double contrast computed tomography scan showed a dilated small bowel with mild free fluid proximal to a transition zone at the distal jejunum. Laparoscopic enterotomy was performed just proximal to the obstruction site, and the balloon was visualized and extracted after it had been incised and emptied. The enterotomy incision was closed with an intracorporeal continuous absorbable suture. The patient’s recovery was uneventful and she was discharged on postoperative day 4. Discussion: We discuss the possible etiologies of SBO following Elipse™ IGB insertion, and present a brief literature review regarding surgical and nonsurgical management options for such cases. Conclusion: Although initial data showed the Elipse™ IGB to be safe, complications can occur and be managed successfully. Keywords: Elipse, Intragastric balloon, Capsule, Obesity, Case report

  8. Laser Fenestration of Aortic Stent-Grafts Followed by Noncompliant vs Cutting Balloon Dilation: A Scanning Electron Microscopy Study.

    Science.gov (United States)

    Lin, Jing; Parikh, Niraj; Udgiri, Naval; Wang, Shaoxia; Miller, Daniel F; Li, Chaojing; Panneton, Jean; Nutley, Mark; Zhang, Ze; Huang, Yunfan; Lu, Jun; Zhang, Jingyi; Wang, Lu; Guidoin, Robert

    2018-06-01

    To examine the effects of in situ laser fenestration and subsequent balloon dilation (noncompliant vs cutting) on the graft fabric of 4 aortic stent-graft models. In an in vitro setup, the Zenith TX2, Talent, Endurant, and Anaconda aortic stent-grafts (all made of polyester graft material) were subjected to laser fenestration with a 2.3-mm-diameter probe at low and high energy in a physiologic saline solution followed by balloon dilation of the hole. For the first series of tests, 6-mm-diameter noncompliant balloons were used and replaced for the second series by 6-mm-diameter cutting balloons. Each procedure was performed 5 times (5 fenestrations per balloon type). The fenestrations were examined visually and with light and scanning electron microscopy. Each fenestration demonstrated various degrees of fraying and/or tearing regardless of the device. The monofilament twill weave of the Talent endograft tore in the warp direction up to 7.09±0.46 mm at high energy compared with 2.41±0.26 mm for the Endurant multifilament device. The fenestrations of the 3 endografts with multifilament weave (Zenith, Anaconda, and Endurant) showed more fraying; fenestration areas in the multifilament Endurant were >10 mm 2 at low and high energy. The fenestrations were free of melted fibers, but minor blackening of the filaments was observed in all devices. Overall, the cutting balloons resulted in worse tearing and damage. Of note, the edges of the dilated laser-formed fenestrations of the Talent and the Endurant grafts demonstrated evidence of additional shredded yarns. In situ fenestration does not cause any melting of the polyester; however, the observed structural damage to the fabric construction must be carefully considered. Cutting balloons caused various levels of tearing compared to the noncompliant balloons and cannot be recommended for use in this application. Rather, noncompliant balloons should be employed, but only with endografts constructed from multifilament yarns

  9. Comparison of results of Bakri balloon tamponade and caesarean hysterectomy in management of placenta accreta and increta: a retrospective study.

    Science.gov (United States)

    Pala, Şehmus; Atilgan, Remzi; Başpınar, Melike; Kavak, Ebru Çelik; Yavuzkır, Şeyda; Akyol, Alparslan; Kavak, Burçin

    2018-02-01

    The aim of this study was to compare the postoperative results of the patients who were treated with Bakri balloon tamponade or hysterectomy for placenta accreta and increta. Patients who were diagnosed with placenta accreta or increta preoperatively and intraoperatively and treated with Bakri balloon tamponade (Group 1) or caesarean hysterectomy (Group 2) were compared in regards to the postoperative results. Among the 36 patients diagnosed with placenta accreta or increta, 19 patients were treated with Bakri balloon tamponade while 17 cases were treated with hysterectomy. Intraoperative blood loss amount was 1794 ± 725 ml in G1, which was lower than that in G2 (2694 ± 893 ml). Blood transfusion amount was 2.7 ± 2.6 units in G1, lower than that in G2 (5.7 ± 2.4 units), too. Operation time was 64.5 ± 29 min and 140 ± 51 min in G1 and G2, respectively, showing significant differences between two groups. The success rate of Bakri balloon was determined as 84.21%. In conclusion, cases with placenta accreta/increta, with predicted placental detachment who are willing to preserve fertility, application of uterine balloon tamponade devices before the hysterectomy is encouraging with its advantages compared with the hysterectomy. Impact statement What is already known on this subject: Invasive placental anomalies are the most common indication of postpartum hysterectomy. Recently, uterine balloon tamponade was also included in the treatment modalities of postpartum haemorrhage.This study aimed to compare the postoperative results of UBT or hysterectomy for patients with placenta accreta and increta. What the results of this study add: In this study, the total amount of blood loss was higher in the caesarean hysterectomy group when compared with the Bakri balloon tamponade group. The mean transfusion requirement, mean operation time and hospitalisation period was significantly longer in the caesarean hysterectomy group. The success

  10. Significant change in the construction of a door to a room with slowed down neutron field by means of commonly used inexpensive protective materials

    International Nuclear Information System (INIS)

    Konefal, Adam; Laciak, Marcin; Dawidowska, Anna; Osewski, Wojciech

    2014-01-01

    The detailed analysis of nuclear reactions occurring in materials of the door is presented for the typical construction of an entrance door to a room with a slowed down neutron field. The changes in the construction of the door were determined to reduce effectively the level of neutron and gamma radiation in the vicinity of the door in a room adjoining the neutron field room. Optimisation of the door construction was performed with the use of Monte Carlo calculations (GEANT4). The construction proposed in this paper bases on the commonly used inexpensive protective materials such as borax (13.4 cm), lead (4 cm) and stainless steel (0.1 and 0.5 cm on the side of the neutron field room and of the adjoining room, respectively). The improved construction of the door, worked out in the presented studies, can be an effective protection against neutrons with energies up to 1 MeV (authors)

  11. Sosiaalisen median mahdollisuudet Tilastokeskukselle

    OpenAIRE

    Vesterinen, Anu

    2011-01-01

    Tämän opinnäytetyön aiheena oli sosiaalisen median mahdollisuudet Tilastokeskuksen viestinnässä. Työn tavoitteena oli kartoittaa sosiaalisen median käyttöön liittyviä mahdollisuuksia ja haasteita sekä selvittää siihen liittyviä odotuksia Tilastokeskuksen henkilöstön keskuudessa. Työn teoriaosuudessa tarkasteltiin sosiaalista mediaa käsitteenä ja esiteltiin sosiaalisen median käyttöä organisaation ulkoisen viestinnän välineenä. Opinnäytetyössä selvitettiin teoriatietoon pohjautuen sekä ca...

  12. Stability analysis and trend study of a balloon tethered in a wind, with experimental comparisons

    Science.gov (United States)

    Redd, L. T.; Bland, S. R.; Bennett, R. M.

    1973-01-01

    A stability analysis and trend study for a balloon tethered in a steady wind are presented. The linearized, stability-derivative type analysis includes balloon aerodynamics, buoyancy, mass (including apparent mass), and static forces resulting from the tether cable. The analysis has been applied to a balloon 7.64 m in length, and the results are compared with those from tow tests of this balloon. This comparison shows that the analysis gives reasonable predictions for the damping, frequencies, modes of motion, and stability boundaries exhibited by the balloon. A trend study for the 7.64-m balloon was made to illustrate how the stability boundaries are affected by changes in individual stability parameters. The trends indicated in this study may also be applicable to many other tethered-balloon systems.

  13. Angry Birds realized: water balloon launcher for teaching projectile motion with drag

    International Nuclear Information System (INIS)

    Edwards, Boyd F; Sam, David D; Christiansen, Michael A; Booth, William A; Jessup, Leslie O

    2014-01-01

    A simple, collapsible design for a large water balloon slingshot launcher features a fully adjustable initial velocity vector and a balanced launch platform. The design facilitates quantitative explorations of the dependence of the balloon range and time of flight on the initial speed, launch angle, and projectile mass, in an environment where quadratic air drag is important. Presented are theory and experiments that characterize this drag, and theory and experiments that characterize the nonlinear elastic energy and hysteresis of the latex tubing used in the slingshot. The experiments can be carried out with inexpensive and readily available tools and materials. The launcher provides an engaging way to teach projectile motion and elastic energy to students of a wide variety of ages. (paper)

  14. Fasting and meal-induced CCK and PP secretion following intragastric balloon treatment for obesity.

    Science.gov (United States)

    Mathus-Vliegen, Elisabeth M H; de Groot, Gerrit H

    2013-05-01

    Satiety is centrally and peripherally mediated by gastrointestinal peptides and the vagal nerve. We aimed to investigate whether intragastric balloon treatment affects satiety through effects on fasting and meal-stimulated cholecystokinin (CCK) and pancreatic polypeptide (PP) secretion. Patients referred for obesity treatment were randomised to 13 weeks of sham treatment followed by 13 weeks of balloon treatment (group 1; sham/balloon) or to twice a 13-week period of balloon treatment (group 2; balloon/balloon). Blood samples were taken for fasting and meal-stimulated CCK and PP levels at the start (T0) and after 13 (T1) and 26 (T2) weeks. Patients filled out visual analogue scales (VAS) to assess satiety. Forty-two patients (35 females, body weight 125.1 kg, BMI 43.3 kg/m(2)) participated. In group 1, basal CCK levels decreased but meal-stimulated response remained unchanged after 13 weeks of sham treatment. In group 2, basal and meal-stimulated CCK levels decreased after 13 weeks of balloon treatment. At the end of the second 13-week period, when group 1 had their first balloon treatment, they duplicated the initial 13-week results of group 2, whereas group 2 continued their balloon treatment and reduced meal-stimulated CCK release. Both groups showed reduced meal-stimulated PP secretions at T1 and T2 compared to T0. Changes in diet composition and VAS scores were similar. Improvements in glucose homeostasis partly explained the PP results. The reduced CCK and PP secretion after balloon positioning was unexpected and may reflect delayed gastric emptying induced by the balloon. Improved glucose metabolism partly explained the reduced PP secretion. Satiety and weight loss were not adversely influenced by these hormonal changes.

  15. Single-centre comparison of a novel single-step balloon inflation ...

    African Journals Online (AJOL)

    Objective. A new second-generation balloon dilatation device for percutaneous nephrolithotomy (PCNL) has been launched, promising to challenge the traditional Amplatz serial dilators (ASDs). This device allows for the polyurethane sheath to be deployed on balloon inflation. Our primary objective in this pilot study was to ...

  16. High Altitude Balloons as a Platform for Space Radiation Belt Science

    Science.gov (United States)

    Mazzino, L.; Buttenschoen, A.; Farr, Q.; Hodgson, C.; Johnson, W.; Mann, I. R.; Rae, J.; University of Alberta High Altitude Balloons (UA-HAB)

    2011-12-01

    The goals of the University of Alberta High Altitude Balloons Program (UA-HAB) are to i) use low cost balloons to address space radiation science, and ii) to utilise the excitement of "space mission" involvement to promote and facilitate the recruitment of undergraduate and graduate students in physics, engineering, and atmospheric sciences to pursue careers in space science and engineering. The University of Alberta High Altitude Balloons (UA-HAB) is a unique opportunity for University of Alberta students (undergraduate and graduate) to engage in the hands-on design, development, build, test and flight of a payload to operate on a high altitude balloon at around 30km altitude. The program development, including formal design and acceptance tests, reports and reviews, mirror those required in the development of an orbital satellite mission. This enables the students to gain a unique insight into how space missions are flown. UA-HAB is a one and half year program that offers a gateway into a high-altitude balloon mission through hands on experience, and builds skills for students who may be attracted to participate in future space missions in their careers. This early education will provide students with the experience necessary to better assess opportunities for pursuing a career in space science. Balloons offer a low-cost alternative to other suborbital platforms which can be used to address radiation belt science goals. In particular, the participants of this program have written grant proposal to secure funds for this project, have launched several 'weather balloon missions', and have designed, built, tested, and launched their particle detector called "Maple Leaf Particle Detector". This detector was focussed on monitoring cosmic rays and space radiation using shielded Geiger tubes, and was flown as one of the payloads from the institutions participating in the High Altitude Student Platform (HASP), organized by the Louisiana State University and the Louisiana

  17. FDS5 Simulation for OECD PRISME Fire Test of DOOR PRSD5

    International Nuclear Information System (INIS)

    Lee, Kyu Bok; Park, Jong Seuk

    2009-01-01

    OECD/NEA PRISME Fire Project is an international co-operation project to investigate fire propagation by means of experiments and analyses for nuclear power plant applications. This project focuses on the generation of experimental data for fire and smoke propagation from the fire room to adjacent rooms under various conditions and room configurations. In addition, analyses using computer codes are performed to understand the phenomena of interest and to produce a consistent interpretation of the experimental results. The PRISME Project is composed of series of tests named as SOURCE, DOOR, LEAK and Global Tests. The SOURCE is composed of tests to characterize the fire source, and the DOOR is to study fire and smoke propagation through an open door, while the LEAK is to investigate hot gas leakages through other modes of openings such as holes, a slot, a duct, and a partially opened door. The Global test will be conducted as integral tests on the basis of the results of the previous separate effects tests. In this paper, simulations are performed with FDS5 computer code for the DOOR Test No.5 (PRS D 5) and the calculation results are compared with the corresponding experimental data to study the code capability to predict the phenomena of the hot gas propagation between two rooms

  18. Modeling the ascent of sounding balloons: derivation of the vertical air motion

    Directory of Open Access Journals (Sweden)

    A. Gallice

    2011-10-01

    Full Text Available A new model to describe the ascent of sounding balloons in the troposphere and lower stratosphere (up to ∼30–35 km altitude is presented. Contrary to previous models, detailed account is taken of both the variation of the drag coefficient with altitude and the heat imbalance between the balloon and the atmosphere. To compensate for the lack of data on the drag coefficient of sounding balloons, a reference curve for the relationship between drag coefficient and Reynolds number is derived from a dataset of flights launched during the Lindenberg Upper Air Methods Intercomparisons (LUAMI campaign. The transfer of heat from the surrounding air into the balloon is accounted for by solving the radial heat diffusion equation inside the balloon. In its present state, the model does not account for solar radiation, i.e. it is only able to describe the ascent of balloons during the night. It could however be adapted to also represent daytime soundings, with solar radiation modeled as a diffusive process. The potential applications of the model include the forecast of the trajectory of sounding balloons, which can be used to increase the accuracy of the match technique, and the derivation of the air vertical velocity. The latter is obtained by subtracting the ascent rate of the balloon in still air calculated by the model from the actual ascent rate. This technique is shown to provide an approximation for the vertical air motion with an uncertainty error of 0.5 m s−1 in the troposphere and 0.2 m s−1 in the stratosphere. An example of extraction of the air vertical velocity is provided in this paper. We show that the air vertical velocities derived from the balloon soundings in this paper are in general agreement with small-scale atmospheric velocity fluctuations related to gravity waves, mechanical turbulence, or other small-scale air motions measured during the SUCCESS campaign (Subsonic Aircraft: Contrail and Cloud Effects

  19. Vascular Rupture Caused by a Molding Balloon during Endovascular Aneurysm Repair: Case Report

    International Nuclear Information System (INIS)

    Lee, Hee Young; Do, Young Soo; Park, Hong Suk; Park, Kwang Bo; Kim, Young Wook; Kim, Dong Ik

    2011-01-01

    Endovascular aneurysm repair (EVAR) has been accepted as an alternative to traditional open surgery in selected patients. Despite the minimally invasiveness of this treatment, several complications may occur during or after EVAR. Complications include endoleak, aortic dissection, distal embolism, or iatrogenic injury to the access artery. However, there are few reports on the vascular rupture caused by a molding balloon during EVAR. We report two cases of infrarenal abdominal aortic aneurysms complicated by procedure-related aortic or iliac artery rupture by the molding balloon during EVAR. In our cases, we observed suddenly abrupt increase of the diameter of the endograft during balloon inflation, because we inflated the balloon rapidly. In conclusion, careful attention must be paid during inflation of the molding balloon to prevent vascular rupture.

  20. Efficient Scalable Median Filtering Using Histogram-Based Operations.

    Science.gov (United States)

    Green, Oded

    2018-05-01

    Median filtering is a smoothing technique for noise removal in images. While there are various implementations of median filtering for a single-core CPU, there are few implementations for accelerators and multi-core systems. Many parallel implementations of median filtering use a sorting algorithm for rearranging the values within a filtering window and taking the median of the sorted value. While using sorting algorithms allows for simple parallel implementations, the cost of the sorting becomes prohibitive as the filtering windows grow. This makes such algorithms, sequential and parallel alike, inefficient. In this work, we introduce the first software parallel median filtering that is non-sorting-based. The new algorithm uses efficient histogram-based operations. These reduce the computational requirements of the new algorithm while also accessing the image fewer times. We show an implementation of our algorithm for both the CPU and NVIDIA's CUDA supported graphics processing unit (GPU). The new algorithm is compared with several other leading CPU and GPU implementations. The CPU implementation has near perfect linear scaling with a speedup on a quad-core system. The GPU implementation is several orders of magnitude faster than the other GPU implementations for mid-size median filters. For small kernels, and , comparison-based approaches are preferable as fewer operations are required. Lastly, the new algorithm is open-source and can be found in the OpenCV library.

  1. Hand sanitizer-dispensing door handles increase hand hygiene compliance: a pilot study.

    Science.gov (United States)

    Babiarz, Lukasz S; Savoie, Brent; McGuire, Mark; McConnell, Lauren; Nagy, Paul

    2014-04-01

    Improving rates of hand hygiene compliance (HHC) has been shown to reduce nosocomial disease. We compared the HHC for a traditional wall-mounted unit and a novel sanitizer-dispensing door handle device in a hospital inpatient ultrasound area. HHC increased 24.5%-77.1% (P sanitizer-dispensing door handle, whereas it remained unchanged for the other rooms. Technical improvements like a sanitizer-dispensing door handle can improve hospital HHC. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  2. [The psychiatric revolution in Quebec, 1950-1962. From asylum to community psychiatry and the open door].

    Science.gov (United States)

    Duprey, Catherine

    2011-01-01

    Psychiatry opens to the world at a time when the very basis of psychiatric practice, namely the asylum, is called into question. Studies appear in Quebec and Canadian journals concurrent to the introduction of new formulas for care, such as the delivery of psychiatric services in general hospitals and clinics, that allow patients to be treated outside the walls of psychiatric hospitals. In addition, postwar psychiatry takes an optimistic view toward the future of children with impairments through the creation of specialized schools and workshops. From the mid-20th century onward, the thinking in psychiatry centres on the open door.

  3. Titan Balloon Convection Model, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This innovative research effort is directed at determining, quantitatively, the convective heat transfer coefficients applicable to a Montgolfiere balloon operating...

  4. Balloon Valvuloplasty of Tricuspid Stenosis: A Retrospective Study of 5 Labrador Retriever Dogs.

    Science.gov (United States)

    Lake-Bakaar, G A; Griffiths, L G; Kittleson, M D

    2017-03-01

    There are limited reports of severe tricuspid valve stenosis in dogs and limited data regarding treatment and outcome. To evaluate clinical signs, echocardiographic features, and outcome of balloon valvuloplasty (BV) in dogs with severe tricuspid valve stenosis (TVS) in which BV was attempted. Five client-owned dogs with severe TVS. Records were retrospectively reviewed and data collected regarding signalment, clinical signs, diagnostic findings, procedures, and outcome. All dogs were Labrador Retrievers. Presenting complaints included episodic weakness/syncope (4/5), abdominal distension (4/5), lethargy (2/5), and exercise intolerance (2/5). The median and range of measurements before BV were as follows: TV mean velocity 1.5 m/s (range 1.4-1.7 m/s); velocity-time integral (VTI) 79.8 cm (42.4-99.1 cm); and TV maximum velocity 2.9 m/s (2.3-3.2 m/s). Measurements (available for 3 of 5 dogs) after BV were as follows: TV mean velocity 1.15 m/s (0.9-1.4 m/s); VTI 44.95 cm (41.4-54.8 cm); and TV maximum velocity 1.15 m/s (1.9-2.3 m/s). The procedure was attempted in all dogs and completed in 4/5 dogs. The largest balloon diameter ranged from 15 mm to 25 mm, and length ranged from 4 cm to 5 cm. Right atrial pressure decreased in 4/5 dogs. All but 1 dog had clinical improvement after BV, but recurrence of clinical signs occurred (2/5). Tricuspid regurgitation worsened in 1 dog culminating in right heart failure and euthanasia. BV can be an effective treatment; however, clinical signs can recur. Right heart failure due to worsened TR is a potential complication in dogs with pre-existing moderate-to-severe TR. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  5. Sosiaalisen median markkinointistrategia

    OpenAIRE

    Tran, Jenny

    2017-01-01

    Insinöörityön tavoitteena oli suunnitella toimeksiantajayritykselle sopiva sosiaalisen median markkinointistrategia ja avustaa sen toteutuksessa sekä tuottaen sisältöä sovittuihin kanaviin. Pyrkimyksenä oli myös kouluttaa yrityksen henkilökuntaa käyttämään sosiaalista mediaa yleisellä tasolla ja markkinoinnissa tutustuttamalla heidät sosiaalisen median erilaisiin kanaviin ja mainostyökaluihin. Opinnäytetyössä keskityttiin tutkimaan Facebookissa toimivaa markkinointia ja siinä toimivia mai...

  6. Experimental investigation of undesired stable equilibria in pumpkin shape super-pressure balloon designs

    Science.gov (United States)

    Schur, W. W.

    2004-01-01

    Excess in skin material of a pneumatic envelope beyond what is required for minimum enclosure of a gas bubble is a necessary but by no means sufficient condition for the existence of multiple equilibrium configurations for that pneumatic envelope. The very design of structurally efficient super-pressure balloons of the pumpkin shape type requires such excess. Undesired stable equilibria in pumpkin shape balloons have been observed on experimental pumpkin shape balloons. These configurations contain regions with stress levels far higher than those predicted for the cyclically symmetric design configuration under maximum pressurization. Successful designs of pumpkin shape super-pressure balloons do not allow such undesired stable equilibria under full pressurization. This work documents efforts made so far and describes efforts still underway by the National Aeronautics and Space Administration's Balloon Program Office to arrive on guidance on the design of pumpkin shape super-pressure balloons that guarantee full and proper deployment.

  7. PULSAR: a balloon-borne experiment to detect variable low energy gamma-ray

    International Nuclear Information System (INIS)

    Bui-Van, N.A.; Martin, I.M.; Blanco, F.G.; Braga, J.

    1983-01-01

    The main goal of the balloon-borne 'PULSAR' experiment is to observe γ-ray photons of variable sources and pulsars in the energy range 0.1-5.0 MeV. The geometrical arrangement of the telescope has been designed according to detector sensitivity estimations for the pulsed radiation, which have been made by empirical and analytical methods. From the obtained results we expect to achieve a detection sensitivity of 3.7 x 10 -7 photons cm -2 s -1 KeV -1 (0.1 - 0.5 MeV) and 4.5 x 10 -6 photons cm -2 s -1 KeV -1 (1.0 - 5.0 MeV), for 5 hours integration time at 5 g cm -2 atmospheric depth, with 3σ statistical significance. It was developed an on-board electronics, compatible with the available telemetry capacity, that is able to process the data with a time resolution of approximatelly 4 miliseconds. (Author) [pt

  8. Biogenic nonmethane hydrocarbon emissions estimated from tethered balloon observations

    Science.gov (United States)

    Davis, K. J.; Lenschow, D. H.; Zimmerman, P. R.

    1994-01-01

    A new technique for estimating surface fluxes of trace gases, the mixed-layer gradient technique, is used to calculate isoprene and terpene emissions from forests. The technique is applied to tethered balloon measurements made over the Amazon forest and a pine-oak forest in Alabama at altitudes up to 300 m. The observations were made during the dry season Amazon Boundary Layer Experiment (ABLE 2A) and the Rural Oxidants in the Southern Environment 1990 experiment (ROSE I). Results from large eddy simulations of scalar transport in the clear convective boundary layer are used to infer fluxes from the balloon profiles. Profiles from the Amazon give a mean daytime emission of 3630 +/- 1400 micrograms isoprene sq m/h, where the uncertainty represents the standard deviation of the mean of eight flux estimates. Twenty profiles from Alabama give emissions of 4470 +/- 3300 micrograms isoprene sq m/h, 1740 +/- 1060 micrograms alpha-pinene sq m/h, and 790 +/- 560 micrograms beta-pinene sq m/h, respectively. These results are in agreement with emissions derived from chemical budgets. The emissions may be overestimated because of uncertainty about how to incorporate the effects of the canopy on the mixed-layer gradients. The large variability in these emission estimates is probably due to the relatively short sampling times of the balloon profiles, though spatially heterogeneous emissions may also play a role. Fluxes derived using this technique are representative of an upwind footprint of several kilometers and are independent of hydrocarbon oxidation rate and mean advection.

  9. Onyx HD-500 embolization of intracranial aneurysms: modified technique using continuous balloon inflation under conscious sedation.

    Science.gov (United States)

    Rahme, Ralph; Grande, Andrew; Jimenez, Lincoln; Abruzzo, Todd A; Ringer, Andrew J

    2014-08-01

    The conventional technique of intracranial aneurysm embolization using Onyx HD-500 (ev3 Neurovascular, Irvine, CA, USA) involves repetitive balloon inflation-deflation cycles under general anesthesia. By limiting parent artery occlusion to 5 minutes, this cyclic technique is thought to minimize cerebral ischemia. However, intermittent balloon deflation may lengthen procedure time and allow balloon migration, resulting in intimal injury or Onyx leakage. We report our experience using a modified technique of uninterrupted Onyx injection with continuous balloon occlusion under conscious sedation. All Onyx embolization procedures for unruptured aneurysms performed by the senior author (A.J.R.) between September 2008 and April 2010 were retrospectively reviewed. Demographic, clinical, angiographic, and procedural data were recorded. Twenty-four embolization procedures were performed in 21 patients with 23 aneurysms, including four recurrences. Twenty aneurysms (87%) involved the paraclinoid or proximal supraclinoid internal carotid artery. Size ranged from 2.5 to 24mm and neck diameter from 2 to 8mm. The modified technique was employed in 19 cases. All but one patient (94.4%) tolerated continuous balloon inflation. Complete occlusion was achieved in 20 aneurysms (83.3%) and subtotal occlusion in three (12.5%). Stable angiographic results were seen in 85%, 94%, 94%, and 100% of patients at 6, 12, 24, and 36months, respectively. There were no deaths. Permanent non-disabling neurological morbidity occurred in one patient (4.2%). Minor, transient, and/or angiographic complications were seen in three patients (12.5%), none related to the technique itself. Onyx embolization of unruptured intracranial aneurysms can be safely and effectively performed using continuous balloon inflation under conscious sedation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Trace gas measurements from tethered balloon platforms

    Science.gov (United States)

    Bandy, Alan R.; Bandy, Terese L.; Youngbluth, Otto; Owens, Thomas L.

    1987-01-01

    Instrumentation and chemical sampling and analysis procedures are described for making measurements of atmospheric carbon disulfide in the concentration range 1-1000 pptv from tethered balloon platforms. Results of a study on the CS2 composition of air downward of a saltwater marsh are reported. A method for obtaining the necessary data for solving the budget equations for surface fluxes, chemical formation rates and chemical destruction rates using data acquired from tethered balloon platforms is presented.

  11. Balloon catheter dilatation of esophageal strictures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeung Sook; Yoon, Yup; Sung, Dong Yook; Choi, Woo Suk; Nam, Kyung Jin; Lim, Jae Hoon [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    1990-07-15

    The authors performed 27 fluoroscopically guided balloon dilatation in 12 patients of esophageal stricture during recent 3 years. The causes of esophageal stricture were corrosive esophagitis (N=2) and congenital narrowing (N=1), including postoperative narrowing in achalasia (N=3), esophageal varix (N=3), lye stricture (N=2) and esophageal cancer (N=1). Successful dilatation of the stricture was achieved during the procedure in 10 patients(83%). Major complication such as esophageal rupture was not found. The authors conclude that fluoroscopically guided esophageal balloon dilatation is a safe and effective method for treatment of symptomatic esophageal strictures.

  12. Balloon catheter dilatation of esophageal strictures

    International Nuclear Information System (INIS)

    Kim, Jeung Sook; Yoon, Yup; Sung, Dong Yook; Choi, Woo Suk; Nam, Kyung Jin; Lim, Jae Hoon

    1990-01-01

    The authors performed 27 fluoroscopically guided balloon dilatation in 12 patients of esophageal stricture during recent 3 years. The causes of esophageal stricture were corrosive esophagitis (N=2) and congenital narrowing (N=1), including postoperative narrowing in achalasia (N=3), esophageal varix (N=3), lye stricture (N=2) and esophageal cancer (N=1). Successful dilatation of the stricture was achieved during the procedure in 10 patients(83%). Major complication such as esophageal rupture was not found. The authors conclude that fluoroscopically guided esophageal balloon dilatation is a safe and effective method for treatment of symptomatic esophageal strictures

  13. A comparison of freeway median crash frequency, severity, and barrier strike outcomes by median barrier type.

    Science.gov (United States)

    Russo, Brendan J; Savolainen, Peter T

    2018-08-01

    Median-crossover crashes are among the most hazardous events that can occur on freeways, often resulting in severe or fatal injuries. The primary countermeasure to reduce the occurrence of such crashes is the installation of a median barrier. When installation of a median barrier is warranted, transportation agencies are faced with the decision among various alternatives including concrete barriers, beam guardrail, or high-tension cable barriers. Each barrier type differs in terms of its deflection characteristics upon impact, the required installation and maintenance costs, and the roadway characteristics (e.g., median width) where installation would be feasible. This study involved an investigation of barrier performance through an in-depth analysis of crash frequency and severity data from freeway segments where high-tension cable, thrie-beam, and concrete median barriers were installed. A comprehensive manual review of crash reports was conducted to identify crashes in which a vehicle left the roadway and encroached into the median. This review also involved an examination of crash outcomes when a barrier strike occurred, which included vehicle containment, penetration, or re-direction onto the travel lanes. The manual review of crash reports provided critical supplementary information through narratives and diagrams not normally available through standard fields on police crash report forms. Statistical models were estimated to identify factors that affect the frequency, severity, and outcomes of median-related crashes, with particular emphases on differences between segments with varying median barrier types. Several roadway-, traffic-, and environmental-related characteristics were found to affect these metrics, with results varying across the different barrier types. The results of this study provide transportation agencies with important guidance as to the in-service performance of various types of median barrier. Copyright © 2018 Elsevier Ltd. All rights

  14. Balloon dilation of congenital supravalvular pulmonic stenosis in a dog.

    Science.gov (United States)

    Treseder, Julia R; Jung, SeungWoo

    2017-03-30

    Percutaneous balloon valvuloplasty is considered the standard of care for treatment of valvular pulmonic stenosis, a common congenital defect in dogs. Supravalvular pulmonic stenosis is a rare form of pulmonic stenosis in dogs and standard treatment has not been established. Although, there have been reports of successful treatment of supravalvular pulmonic stenosis with surgical and stenting techniques, there have been no reports of balloon dilation to treat dogs with this condition. Here, a case of supravalvular pulmonic stenosis diagnosed echocardiographically and angiographically in which a significant reduction in pressure gradient was achieved with balloon dilation alone is presented.

  15. A Comparative Study of Two Different Uncinectomy Techniques: Swing-Door and Classical

    Directory of Open Access Journals (Sweden)

    Ankit A Singhania

    2011-01-01

    Full Text Available Introduction: The aim of this study was to determine which technique of uncinectomy, classical or swing door technique.  Materials and Methods: Four hundred eighty Cases of sinusitis were selected and operated for Functional Endoscopic Sinus Surgery (FESS. Out of these, in 240 uncinectomies classical uncinectomy was done whereas in another 240 uncinectomies swing door technique was used. Initially patients were medically managed treated according to their symptoms and prior management. Patients who had received previous adequate medical management were evaluated with CT scan of the sinuses. If disease still persists than they were operated for FESS. Results: The authors' experience indicates that Functional endoscopic sinus surgery can be performed under local or general anesthesia, as permitted or tolerated. In this review classical technique was used in 240 uncinectomies. Out of this, ethmoidal complex injury was noted in 4 cases, missed maxillary ostium syndrome (incomplete removal was reported in 12 patients and orbital fat exposure was encountered in 5 patients. As compared to 240 uncinectomies done with swing door technique, incomplete removal was evident in 2 cases and lacrimal duct injury was reported in 3 cases. 'Evidence that underscores how this 'swing door technique' successfully combines 'the conservation goals of the anterior-to-posterior approach and anatomic virtues of the posterior-to-anterior approach to ethmoidectomy of the total 480 uncinectomies operated. Out of which 240 uncinectomies have been performed using the 'swing-door' technique. The 240 uncinectomies performed using classical technique were used as controls. The incidence of orbital penetration, incomplete removal, ethmoidal complex injury and ostium non-identification was significantly less with the new technique. Three lacrimal injuries occurred with the 'swing-door' technique compared to no injuries with classical technique. Conclusion: The authors recommend

  16. A comparative study of two different uncinectomy techniques: swing-door and classical.

    Science.gov (United States)

    Singhania, Ankit A; Bansal, Chetan; Chauhan, Nirali; Soni, Saurav

    2012-01-01

    The aim of this study was to determine which technique of uncinectomy, classical or swing door technique. Four hundred eighty Cases of sinusitis were selected and operated for Functional Endoscopic Sinus Surgery (FESS). Out of these, in 240 uncinectomies classical uncinectomy was done whereas in another 240 uncinectomies swing door technique was used. Initially patients were medically managed treated according to their symptoms and prior management. Patients who had received previous adequate medical management were evaluated with CT scan of the sinuses. If disease still persists than they were operated for FESS. The authors' experience indicates that Functional endoscopic sinus surgery can be performed under local or general anesthesia, as permitted or tolerated. In this review classical technique was used in 240 uncinectomies. Out of this, ethmoidal complex injury was noted in 4 cases, missed maxillary ostium syndrome (incomplete removal) was reported in 12 patients and orbital fat exposure was encountered in 5 patients. As compared to 240 uncinectomies done with swing door technique, incomplete removal was evident in 2 cases and lacrimal duct injury was reported in 3 cases. 'Evidence that underscores how this 'swing door technique' successfully combines 'the conservation goals of the anterior-to-posterior approach and anatomic virtues of the posterior-to-anterior approach to ethmoidectomy of the total 480 uncinectomies operated. Out of which 240 uncinectomies have been performed using the 'swing-door' technique. The 240 uncinectomies performed using classical technique were used as controls. The incidence of orbital penetration, incomplete removal, ethmoidal complex injury and ostium non-identification was significantly less with the new technique. Three lacrimal injuries occurred with the 'swing-door' technique compared to no injuries with classical technique. The authors recommend swing door technique as it is easy to learn, allows complete removal of the

  17. Effect of door opening and defrost cycle on a freezer with phase change panels

    International Nuclear Information System (INIS)

    Gin, B.; Farid, M.M.; Bansal, P.K.

    2010-01-01

    An investigation into the effectiveness of phase change material (PCM) panels placed against the internal walls of a freezer to maintain stable temperatures in the presence of heat loads such as door openings, defrosting, and loss of electrical power was carried out. Temperature response was studied during loss of power, a defrost cycle lasting 30 min, and a door opening scheme of 13 door openings over an 11 h period. This PCM system has significantly decreased the rate of temperature increase inside the freezer during defrosting and power loss. Energy consumption was measured during steady operation, a defrost cycle of 30 min, and a scheme of eight door openings at 40 min intervals. It was found that heat loads caused greater energy consumption, and that the presence of PCM during defrosting and door openings resulted in slightly lower energy consumption compared to without PCM.

  18. EUSO-BALLOON a pathfinder for detecting UHECR's from the edge of space

    Directory of Open Access Journals (Sweden)

    Scotti V.

    2013-06-01

    Full Text Available EUSO-Balloon has been conceived as a pathfinder mission for JEM-EUSO, to perform an end-to-end test of the subsystems and components, and to prove the global detection chain while improving our knowledge of the atmospheric and terrestrial UV background. Through a series of stratospheric balloon flights performed by the French Space Agency CNES, EUSO-BALLOON will serve as an evolutive test-bench for all the key technologies of JEM-EUSO. EUSO-Balloon also has the potential to detect Extensive Air Showers from above, marking a key milestone in the development of UHECR science, and paving the way for any future large scale, space-based UHECR observatory.

  19. Time management in acute vertebrobasilar occlusion.

    Science.gov (United States)

    Kamper, Lars; Rybacki, Konrad; Mansour, Michael; Winkler, Sven B; Kempkes, Udo; Haage, Patrick

    2009-03-01

    Acute vertebrobasilar occlusion (VBO) is associated with a high risk of stroke and death. Although local thrombolysis may achieve recanalization and improve outcome, mortality is still between 35% and 75%. However, without recanalization the chance of a good outcome is extremely poor, with mortality rates of 80-90%. Early treatment is a fundamental factor, but detailed studies of the exact time management of the diagnostic and interventional workflow are still lacking. Data on 18 patients were retrospectively evaluated. Time periods between symptom onset, admission to hospital, time of diagnosis, and beginning of intervention were correlated with postinterventional neurological status. The Glasgow Coma Scale and National Institute of Health Stroke Scale (NIHSS) were used to examine patients before and after local thrombolysis. Additionally, multivariate statistics were applied to reveal similarities between patients with neurological improvement. Primary recanalization was achieved in 77% of patients. The overall mortality was 55%. Major complications were intracranial hemorrhage and peripheral embolism. The time period from symptom onset to intervention showed a strong correlation with the postinterventional NIHSS as well as the patient's age, with the best results in a 4-h interval. Multivariate statistics revealed similarities among the patients. Evaluation of time management in acute VBO by multivariate statistics is a helpful tool for definition of similarities in this patient group. Similarly to the door-to-balloon time for acute coronary interventions, the chances for a good outcome depend on a short time interval between symptom onset and intervention. While the only manipulable time period starts with hospital admission, our results emphasize the necessity of efficient intrahospital workflow.

  20. Time Management in Acute Vertebrobasilar Occlusion

    International Nuclear Information System (INIS)

    Kamper, Lars; Rybacki, Konrad; Mansour, Michael; Winkler, Sven B.; Kempkes, Udo; Haage, Patrick

    2009-01-01

    Acute vertebrobasilar occlusion (VBO) is associated with a high risk of stroke and death. Although local thrombolysis may achieve recanalization and improve outcome, mortality is still between 35% and 75%. However, without recanalization the chance of a good outcome is extremely poor, with mortality rates of 80-90%. Early treatment is a fundamental factor, but detailed studies of the exact time management of the diagnostic and interventional workflow are still lacking. Data on 18 patients were retrospectively evaluated. Time periods between symptom onset, admission to hospital, time of diagnosis, and beginning of intervention were correlated with postinterventional neurological status. The Glasgow Coma Scale and National Institute of Health Stroke Scale (NIHSS) were used to examine patients before and after local thrombolysis. Additionally, multivariate statistics were applied to reveal similarities between patients with neurological improvement. Primary recanalization was achieved in 77% of patients. The overall mortality was 55%. Major complications were intracranial hemorrhage and peripheral embolism. The time period from symptom onset to intervention showed a strong correlation with the postinterventional NIHSS as well as the patient's age, with the best results in a 4-h interval. Multivariate statistics revealed similarities among the patients. Evaluation of time management in acute VBO by multivariate statistics is a helpful tool for definition of similarities in this patient group. Similarly to the door-to-balloon time for acute coronary interventions, the chances for a good outcome depend on a short time interval between symptom onset and intervention. While the only manipulable time period starts with hospital admission, our results emphasize the necessity of efficient intrahospital workflow.

  1. Postoperative Outcomes of Mitral Valve Repair for Mitral Restenosis after Percutaneous Balloon Mitral Valvotomy

    Directory of Open Access Journals (Sweden)

    Seong Lee

    2015-10-01

    Full Text Available Background: There have been a number of studies on mitral valve replacement and repeated percutaneous mitral balloon valvotomy for mitral valve restenosis after percutaneous mitral balloon valvotomy. However, studies on mitral valve repair for these patients are rare. In this study, we analyzed postoperative outcomes of mitral valve repair for mitral valve restenosis after percutaneous mitral balloon valvotomy. Methods: In this study, we assessed 15 patients (mean age, 47.7±9.7 years; 11 female and 4 male who underwent mitral valve repair between August 2008 and March 2013 for symptomatic mitral valve restenosis after percutaneous mitral balloon valvotomy. The mean interval between the initial percutaneous mitral balloon valvotomy and the mitral valve repair was 13.5±7 years. The mean preoperative Wilkins score was 9.4±2.6. Results: The mean mitral valve area obtained using planimetry increased from 1.16±0.16 cm2 to 1.62±0.34 cm2 (p=0.0001. The mean pressure half time obtained using Doppler ultrasound decreased from 202.4±58.6 ms to 152±50.2 ms (p=0.0001. The mean pressure gradient obtained using Doppler ultrasound decreased from 9.4±4.0 mmHg to 5.8±1.5 mmHg (p=0.0021. There were no early or late deaths. Thromboembolic events or infective endocarditis did not occur. Reoperations such as mitral valve repair or mitral valve replacement were not performed during the follow-up period (39±16 months. The 5-year event-free survival was 56.16% (95% confidence interval, 47.467–64.866. Conclusion: On the basis of these results, we could not conclude that mitral valve repair could be an alternative for patients with mitral valve restenosis after percutaneous balloon mitral valvotomy. However, some patients presented with results similar to those of mitral valve replacement. Further studies including more patients with long-term follow-up are necessary to determine the possibility of this application of mitral valve repair.

  2. Significant change in the construction of a door to a room with slowed down neutron field by means of commonly used inexpensive protective materials.

    Science.gov (United States)

    Konefał, Adam; Łaciak, Marcin; Dawidowska, Anna; Osewski, Wojciech

    2014-12-01

    The detailed analysis of nuclear reactions occurring in materials of the door is presented for the typical construction of an entrance door to a room with a slowed down neutron field. The changes in the construction of the door were determined to reduce effectively the level of neutron and gamma radiation in the vicinity of the door in a room adjoining the neutron field room. Optimisation of the door construction was performed with the use of Monte Carlo calculations (GEANT4). The construction proposed in this paper bases on the commonly used inexpensive protective materials such as borax (13.4 cm), lead (4 cm) and stainless steel (0.1 and 0.5 cm on the side of the neutron field room and of the adjoining room, respectively). The improved construction of the door, worked out in the presented studies, can be an effective protection against neutrons with energies up to 1 MeV. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Microcontroller uses in Long-Duration Ballooning

    Science.gov (United States)

    Jones, Joseph

    This paper discusses how microcontrollers are being utilized to fulfill the demands of long duration ballooning (LDB) and the advantages of doing so. The Columbia Scientific Balloon Facility (CSBF) offers the service of launching high altitude balloons (120k ft) which provide an over the horizon telemetry system and platform for scientific research payloads to collect data. CSBF has utilized microcontrollers to address multiple tasks and functions which were previously performed by more complex systems. A microcontroller system has been recently developed and programmed in house to replace our previous backup navigation system which is used on all LDB flights. A similar microcontroller system was developed to be independently launched in Antarctica before the actual scientific payload. This system's function is to transmit its GPS position and a small housekeeping packet so that we can confirm the upper level float winds are as predicted from satellite derived models. Microcontrollers have also been used to create test equipment to functionally check out the flight hardware used in our telemetry systems. One test system which was developed can be used to quickly determine if our communication link we are providing for the science payloads is functioning properly. Another system was developed to provide us with the ability to easily determine the status of one of our over the horizon communication links through a closed loop system. This test system has given us the capability to provide more field support to science groups than we were able to in years past. The trend of utilizing microcontrollers has taken place for a number of reasons. By using microcontrollers to fill these needs, it has given us the ability to quickly design and implement systems which meet flight critical needs, as well as perform many of the everyday tasks in LDB. This route has also allowed us to reduce the amount of time required for personnel to perform a number of the tasks required

  4. Viscoresistive g-modes and ballooning

    International Nuclear Information System (INIS)

    Dagazian, R.Y.; Paris, R.B.

    1980-01-01

    The resistive G-mode and its particular form, the resistive ballooning mode, are treated as limits of a single simple model. MHD theory including parallel and perpendicular viscosity, finite shear, and finite beta is employed to study their linear stability

  5. Treatment of multiple-level tracheobronchial stenosis secondary to endobronchial tuberculosis using bronchoscopic balloon dilatation with topical mitomycin-C.

    Science.gov (United States)

    Faisal, Mohamed; Harun, Hafaruzi; Hassan, Tidi M; Ban, Andrea Y L; Chotirmall, Sanjay H; Abdul Rahaman, Jamalul Azizi

    2016-04-14

    Tracheobronchial stenosis is a known complication of endobronchial tuberculosis. Despite antituberculous and steroid therapy, the development of bronchial stenosis is usually irreversible and requires airway patency to be restored by either bronchoscopic or surgical interventions. We report the use of balloon dilatation and topical mitomycin-C to successful restore airway patency. We present a 24-year old lady with previous pulmonary tuberculosis and laryngeal tuberculosis in 2007 and 2013 respectively who presented with worsening dyspnoea and stridor. She had total left lung collapse with stenosis of both the upper trachea and left main bronchus. She underwent successful bronchoscopic balloon and manual rigid tube dilatation with topical mitomycin-C application over the stenotic tracheal segment. A second bronchoscopic intervention was performed after 20 weeks for the left main bronchus stenosis with serial balloon dilatation and topical mitomycin-C application. These interventions led to significant clinical and radiographic improvements. This case highlights that balloon dilatation and topical mitomycin-C application should be considered in selected patients with tracheobronchial stenosis following endobronchial tuberculosis, avoiding airway stenting and invasive surgical intervention.

  6. Hamming's "open doors" and group creativity as keys to scientific excellence: the example of Cambridge.

    Science.gov (United States)

    Erren, Thomas C

    2008-01-01

    Dr. Charlton used diverse approaches to identify research institutions which provided home to outstanding scientists and work. One intriguing example of long-lasting scientific excellence is Cambridge with 19 Nobel laureates who worked at the University or at the MRC Molecular Biology Unit when they received the prize between 1947 and 2006. With specific reference to Cambridge, I would like to complement the primarily quantitative assessment and offer considerations as to why and how research achievements may have clustered in space and time. Indeed, observations voiced by the mathematician Richard Hamming as to how great research can be pursued offer explanations for the series of great science in the UK. In my view, the most important determinant of the clustering may be illustrated by Hamming's fitting picture of "open doors": working in environments with the doors open allows constant interactions with peers with various disciplinary backgrounds, and thus fast avoidance of detours or dead ends in science and, ultimately, a focus on and the solution of problems of paramount, rather than of tangential, importance. Narrative insights into a strong argumentative tradition at Cambridge provided by Drs. Watson and Magueijo between 1968 and 2003 are in line with Hamming's suggestion and the value of group creativity. In the internet age with abundant interactions beyond home institutions we should not be surprised if clusters of great science were no longer confined to the usual suspect institutions which were awarded disproportionally with Nobel prizes in the past.

  7. Time-Driven Activity-Based Costing: A Comparative Cost Analysis of Whole-Breast Radiotherapy Versus Balloon-Based Brachytherapy in the Management of Early-Stage Breast Cancer.

    Science.gov (United States)

    Schutzer, Matthew E; Arthur, Douglas W; Anscher, Mitchell S

    2016-05-01

    Value in health care is defined as outcomes achieved per dollar spent, and understanding cost is critical to delivering high-value care. Traditional costing methods reflect charges rather than fundamental costs to provide a service. The more rigorous method of time-driven activity-based costing was used to compare cost between whole-breast radiotherapy (WBRT) and accelerated partial-breast irradiation (APBI) using balloon-based brachytherapy. For WBRT (25 fractions with five-fraction boost) and APBI (10 fractions twice daily), process maps were created outlining each activity from consultation to post-treatment follow up. Through staff interviews, time estimates were obtained for each activity. The capacity cost rates (CCR), defined as cost per minute, were calculated for personnel, equipment, and physical space. Total cost was calculated by multiplying the time required of each resource by its CCR. This was then summed and combined with cost of consumable materials. The total cost for WBRT was $5,333 and comprised 56% personnel costs and 44% space/equipment costs. For APBI, the total cost was $6,941 (30% higher than WBRT) and comprised 51% personnel costs, 6% space/equipment costs, and 43% consumable materials costs. The attending physician had the highest CCR of all personnel ($4.28/min), and APBI required 24% more attending time than WBRT. The most expensive activity for APBI was balloon placement and for WBRT was computed tomography simulation. APBI cost more than WBRT when using the dose/fractionation schemes analyzed. Future research should use time-driven activity-based costing to better understand cost with the aim of reducing expenditure and defining bundled payments. Copyright © 2016 by American Society of Clinical Oncology.

  8. GPU Accelerated Vector Median Filter

    Science.gov (United States)

    Aras, Rifat; Shen, Yuzhong

    2011-01-01

    Noise reduction is an important step for most image processing tasks. For three channel color images, a widely used technique is vector median filter in which color values of pixels are treated as 3-component vectors. Vector median filters are computationally expensive; for a window size of n x n, each of the n(sup 2) vectors has to be compared with other n(sup 2) - 1 vectors in distances. General purpose computation on graphics processing units (GPUs) is the paradigm of utilizing high-performance many-core GPU architectures for computation tasks that are normally handled by CPUs. In this work. NVIDIA's Compute Unified Device Architecture (CUDA) paradigm is used to accelerate vector median filtering. which has to the best of our knowledge never been done before. The performance of GPU accelerated vector median filter is compared to that of the CPU and MPI-based versions for different image and window sizes, Initial findings of the study showed 100x improvement of performance of vector median filter implementation on GPUs over CPU implementations and further speed-up is expected after more extensive optimizations of the GPU algorithm .

  9. Endovascular rescue of a fused monorail balloon and cerebral protection device.

    Science.gov (United States)

    Campbell, John E; Bates, Mark C; Elmore, Michael

    2007-08-01

    To present a case of successful endovascular retrieval of a monorail predilation balloon fused to an embolic protection device (EPD) in the distal internal carotid artery (ICA) of a high-risk symptomatic patient. A 60-year-old man with documented systemic atherosclerotic disease had a severe (>70%) restenosis in the left ICA 3 years after endarterectomy. He was scheduled for carotid artery stenting (CAS) with cerebral protection; however, he developed unstable angina and was transferred to our facility, where the admitting team decided that staged CAS followed by coronary bypass grafting would be the best option. During the CAS procedure, a 6-mm AccuNet filter was passed across the lesion via a 6-F carotid sheath and deployed in the distal ICA without incident. However, the 4-x20-mm predilation monorail balloon was then advanced without visualizing the markers, resulting in inadvertent aggressive interaction that trapped the balloon's tip in the filter. Several maneuvers to separate the devices were unsuccessful. Finally, the filter/balloon combination was moved gently retrograde until the balloon was straddling the subtotal ICA lesion. The lesion was dilated to 4 mm with the balloon, and the sheath was gently advanced across the lesion as the balloon was deflated. Angiography excluded interval occlusion of the filter from the embolic debris during the aforementioned aggressive maneuvers and documented antegrade flow. The filter was slowly withdrawn into the 6-F sheath with simultaneous aspiration. A second 6-mm filter was deployed, and the procedure was completed satisfactorily. The patient did well, with no neurological sequelae. EPDs are an essential in carotid artery stenting and, keeping in mind the potential risks associated with their use, will help the operator avoid complications such as this one.

  10. Analysis of current diffusive ballooning mode in tokamaks

    International Nuclear Information System (INIS)

    Uchida, M.; Fukuyama, A.; Itoh, S.-I.; Yagi, M.

    1999-12-01

    The effect of finite gyroradius on the current diffusive ballooning mode is examined. Starting from the reduced MHD equations including turbulent transports, coupling with drift motion and finite gyroradius effect of ions, we derive a ballooning mode equation with complex transport coefficients. The eigenfrequency, saturation level and thermal diffusivity are evaluated numerically from the marginal stability condition. Preliminary results of their parameter dependence is presented. (author)

  11. Balloon dacryocystoplasty study in the management of adult epiphora.

    LENUS (Irish Health Repository)

    Fenton, S

    2012-02-03

    PURPOSE: To determine the efficacy of dacryocystoplasty with balloon dilation in the treatment of acquired obstruction of the nasolacrimal system in adults. METHODS: Balloon dacryocystoplasty was performed in 52 eyes of 42 patients under general anaesthetic. A Teflon-coated guidewire was introduced through the canaliculus and manipulated through the nasolacrimal system and out of the nasal aperture. A 4 mm wide 3 cm coronary angioplasty balloon catheter was threaded over the guidewire in a retrograde fashion and dilated at the site of obstruction. RESULTS: There was complete obstruction in 30% of cases and partial obstruction in 70%. The most common site of obstruction was the nasolacrimal duct. The procedure was technically successful in 94% of cases. The overall re-obstruction rate was 29% within 1 year of the procedure. There was an anatomical failure rate of 17% for partial obstruction and 69% for complete obstruction within 1 year. CONCLUSIONS: Balloon dacryocystoplasty has a high recurrence rate. There may be a limited role for this procedure in partial obstructions. Further refinements of the procedure are necessary before it can be offered as a comparable alternative to a standard surgical dacryocystorhinostomy.

  12. Anchoring barbs and balloon expandable stents: what is the risk of perforation and failed stent deployment?

    Science.gov (United States)

    Bown, M J; Harrison, G J; How, T V; Brennan, J A; Fisher, R K; Vallabhaneni, S R; McWilliams, R G

    2012-09-01

    Balloon expandable stents may on occasion be deployed in close proximity to the anchoring barbs of endovascular grafts. The aim of this study was to determine the risk and effect of balloon perforation by anchoring barbs and to assess whether these risks are different if the balloon is protected by a covered stent mounted upon it. A bench-top model was developed to mimic the penetration of anchoring barbs into the lumen of medium sized blood vessels. The model allowed variation of angle and depth of vessel penetration. Both bare balloons and those with covered stents mounted upon them were tested in the model to determine whether there was a risk of perforation and which factors increased or decreased this risk. All combinations of barb angle and depth caused balloon perforation but this was most marked when the barb was placed perpendicular to the long axis of the balloon. When the deployment of covered stents was attempted balloon perforation occurred in some cases but full stent deployment was achieved in all cases where the perforation was in the portion of the balloon covered by the stent. The only situation in which stent deployment failed was where the barb was intentionally placed in the uncovered portion of the balloon. This resulted in only partial deployment of the stent. Balloon rupture is a distinct possibility when deploying balloon-expandable stents in close proximity to anchoring barbs. Care should be taken in this circumstance to ensure that the barb is well away from the uncovered portion of the balloon. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Balloon dilatations of esophageal strictures

    International Nuclear Information System (INIS)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De

    1990-01-01

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used

  14. Balloon dilatations of esophageal strictures

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Seoul (Korea, Republic of)

    1990-04-15

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used.

  15. Malignant Esophagogastric Junction Obstruction: Efficacy of Balloon Dilation Combined with Chemotherapy and/or Radiation Therapy

    International Nuclear Information System (INIS)

    Ko, Gi-Young; Song, Ho-Young; Hong, Heuk-Jin; Sung, Kyu-Bo; Seo, Tae-Seok; Yoon, Hyun-Ki

    2003-01-01

    Purpose: To assess the efficacy of balloon dilation combined with chemotherapy and/or radiation therapy for palliation of dysphagia due to malignant esophagogastric junction strictures. Methods: Fluoroscopically guided balloon dilation was attempted in 20 patients. The causes of strictures were gastric adenocarcinoma (n = 10) and esophageal squamous cell carcinoma (n = 10). Scheduled chemotherapy and/or radiation therapy followed balloon dilation in all patients. Results: There were no technical failures or major complications. After balloon dilation, 15 (75%) patients showed improvement of dysphagia. No patient complained of reflux esophagitis during the follow-up period. Among the 15 patients, seven needed no further treatment for palliation of dysphagia until their deaths. The remaining eight patients underwent repeat balloon dilation(n = 4) or stent placement (n = 4)3-43 weeks (mean 15 weeks) after the initial balloon dilation because of recurrent dysphagia. Conclusion: Balloon dilation combined with chemotherapy and/or radiation therapy seems to be an easy and reasonably effective palliative treatment for malignant esophagogastric strictures

  16. Gaffkemia van kreeften door Aerococcus viridans

    NARCIS (Netherlands)

    Engelsma, M.Y.; Haenen, O.L.M.

    2011-01-01

    Artikel over een bacteriële ziekte van onder andere kreeften, de zogenaamde Gaffkemia, veroorzaakt door de bacterie Aerococcus viridans. Deze ziekte is in Nederland nog niet eerder gevonden bij kreeften, maar zou met importen van kreeftachtigen mee kunnen komen.

  17. Numerical Modelling Of Pumpkin Balloon Instability

    Science.gov (United States)

    Wakefield, D.

    Tensys have been involved in the numerical formfinding and load analysis of architectural stressed membrane structures for 15 years. They have recently broadened this range of activities into the `lighter than air' field with significant involvement in aerostat and heavy-lift hybrid airship design. Since early 2004 they have been investigating pumpkin balloon instability on behalf of the NASA ULDB programme. These studies are undertaken using inTENS, an in-house finite element program suite based upon the Dynamic Relaxation solution method and developed especially for the non-linear analysis and patterning of membrane structures. The paper describes the current state of an investigation that started with a numerical simulation of the lobed cylinder problem first studied by Calladine. The influence of material properties and local geometric deformation on stability is demonstrated. A number of models of complete pumpkin balloons have then been established, including a 64-gore balloon with geometry based upon Julian Nott's Endeavour. This latter clefted dramatically upon initial inflation, a phenomenon that has been reproduced in the numerical model. Ongoing investigations include the introduction of membrane contact modelling into inTENS and correlation studies with the series of large-scale ULDB models currently in preparation.

  18. Double-Balloon-Assisted n-Butyl-2-Cyanoacrylate Embolization of Intrahepatic Arterioportal Shunt Prior to Chemoembolization of Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Takao, Hidemasa, E-mail: takaoh-tky@umin.ac.jp; Shibata, Eisuke; Ohtomo, Kuni [University of Tokyo, Department of Radiology, Graduate School of Medicine (Japan)

    2016-10-15

    A case of multiple hepatocellular carcinomas with a severe intrahepatic arterioportal shunt that was successfully embolized with n-butyl-2-cyanoacrylate with coaxial double-balloon occlusion prior to transcatheter arterial chemoembolization is presented. A proximal balloon positioned at the proper hepatic artery was used for flow control, and a coaxial microballoon, positioned in the closest of three arterial feeding branches to the arterioportal shunt, was used to control the delivery of n-butyl-2-cyanoacrylate. This coaxial double-balloon technique can prevent proximal embolization and distal migration of n-butyl-2-cyanoacrylate and enable precise control of the distribution of n-butyl-2-cyanoacrylate. It could also be applicable to n-butyl-2-cyanoacrylate embolization for other than intrahepatic arterioportal shunt.

  19. Endoscopic minor papilla balloon dilation for the treatment of symptomatic pancreas divisum.

    Science.gov (United States)

    Yamamoto, Natsuyo; Isayama, Hiroyuki; Sasahira, Naoki; Tsujino, Takeshi; Nakai, Yousuke; Miyabayashi, Koji; Mizuno, Suguru; Kogure, Hirofumi; Sasaki, Takashi; Hirano, Kenji; Tada, Minoru; Koike, Kazuhiko

    2014-08-01

    A subpopulation of patients with pancreas divisum experience symptomatic events such as recurrent acute pancreatitis and chronic pancreatitis. Minor papilla sphincterotomy has been reported as being an effective treatment. The aim of this study was to evaluate the safety and efficacy of endoscopic balloon dilation for the minor papilla. Between 2000 and 2012, 16 patients were retrospectively included in this study. After endoscopic balloon dilation for the minor papilla was received, a pancreatic stent or a nasal pancreatic drainage catheter was placed for 1 week. If a stricture or obstruction was evident, it was treated with balloon dilation followed by long-term stent placement (1 year). When an outflow of pancreatic juice was disturbed by a pancreatic stone, endoscopic stone extraction was performed. Balloon dilation and stent placement were achieved and were successful in all the cases (16/16; 100%). Clinical improvement was achieved in 7 (84.7%) of the 9 patients with recurrent acute pancreatitis and in 6 (85.7%) of the 7 patients with chronic pancreatitis. Early complications were observed in 1 (6.3%) patient. Pancreatitis or bleeding related to balloon dilation was not observed. Endoscopic balloon dilation for the minor papilla is feasible for the management of symptomatic pancreas divisum.

  20. Study of recurrent branch of median nerve (Thenar's muscular branch in relation to the flexor retinaculum and median in 64 hands (32 Men

    Directory of Open Access Journals (Sweden)

    Amirsadri R

    1998-07-01

    Full Text Available Variation of recurred branch of median nerve in relation to the median and flexor retinaculum are significant for both hand surgeons and specialists always. In this study, 64 cadaver hands (32 men have been dissected. The median nerve was identified at the proximal edge of the flexor retinaculum, and in order to expose carpal tunnel the ligament was divided, and the above subjects were studied. The results are: 1 The relation of recurrent nerve to the flexor retinaculum was classified into 4 types: A In (53.1% of subjects, this branch arises from the median after the flexor retinaculum. B In (31.3% of subjects, it arises from the median in the carpal tunnel and the moves around the lower edge of flexor retinaculum and enters the thenar region. C In (14.1% of subjects, it arises from the median in the carpal tunnel and pierces the flexor retinaculum. D In (1.56% of subjects it arises, in the carpal tunnel and it divides into two subbranches here. One follows pattern A and the other pattern C. 2 In this step, the relation of the recurrent branch to the median nerve was studied. The results show that inspite of this image even though most often the recurrent branch arises from the lateral side of median, in (68.75% of subjects it arises from it's anterior surface. The MC Nemar test reveals that there is no relation between manifestation of mentioned patterns with right or left hands.