  1. Measurement of Dynamic Urethral Pressures with a High Resolution Manometry System in Continent and Incontinent Women

    Science.gov (United States)

    Kirby, Anna C; Tan-Kim, Jasmine; Nager, Charles W.

    2015-01-01

    Objectives Female stress urinary incontinence (SUI) is caused by urethral dysfunction during dynamic conditions, but current technology has limitations in measuring urethral pressures under dynamic conditions. An 8-French high resolution manometry catheter (HRM) currently in clinical use in gastroenterology may accurately measure urethral pressures under dynamic conditions because it has a 25ms response rate and circumferential pressure sensors along the length of the catheter (ManoScan® ESO, Given Imaging). We evaluated the concordance, repeatability, and tolerability of this catheter. Methods We measured resting, cough, and strain maximum urethral closure pressures (MUCPs) using HRM and measured resting MUCPs with water perfusion side-hole catheter urethral pressure profilometry (UPP) in 37 continent and 28 stress incontinent subjects. Maneuvers were repeated after moving the HRM catheter along the urethral length to evaluate whether results depend on catheter positioning. Visual analog pain scores evaluated the comfort of HRM compared to UPP. Results The correlation coefficient for resting MUCPs measured by HRM vs. UPP was high (r = 0.79, prest, cough, and strain with HRM: r= 0.92, 0.89, and 0.89. Mean MUCPs (rest, cough, strain) were higher in continent than incontinent subjects (all p continent subjects during cough and strain maneuvers compared to rest. Conclusions This preliminary study shows that HRM is concordant with standard technology, repeatable, and well tolerated in the urethra. Incontinent women have more impairment of their urethral closure pressures during cough and strain than continent women. PMID:25185595

  2. Urethral pressure reflectometry. A method for simultaneous measurements of pressure and cross-sectional area in the female urethra

    DEFF Research Database (Denmark)

    Klarskov, Niels

    2012-01-01

    A novel technique for simultaneous measurements of pressure and cross-sectional area (CA) in the female urethra, denoted Urethral Pressure Reflectometry (UPR), was devised. A very thin and highly flexible polyurethane-bag was placed in the urethra. A pump applied increasing and decreasing pressur...

  3. Pressure/cross-sectional area probe in the assessment of urethral closure function. Reproducibility of measurement

    DEFF Research Database (Denmark)

    Lose, G; Schroeder, T

    1990-01-01

    A probe, which enables measurement of related values of pressure and cross-sectional area, was used for in vitro studies and in vivo measurements in the female urethra. Six healthy females underwent two successive investigations. Measurements were performed at the bladder neck, in the high......-pressure zone and distally in the urethra. The in vitro study showed that cross sectional areas of 13-79 mm2 were determined with a SD of 1.4 mm2. In vivo measurements revealed that the urethral parameters: elastance, hysteresis, pressure and power of contraction during coughing and squeezing were fairly...

  4. Measurement of dynamic urethral pressures with a high-resolution manometry system in continent and incontinent women.

    Science.gov (United States)

    Kirby, Anna C; Tan-Kim, Jasmine; Nager, Charles W

    2015-01-01

    Female stress urinary incontinence is caused by urethral dysfunction during dynamic conditions, but current technology has limitations in measuring urethral pressures under these conditions. An 8-French high-resolution manometry (HRM) catheter currently in clinical use in gastroenterology may accurately measure urethral pressures under dynamic conditions because it has a 25-millisecond response rate and circumferential pressure sensors along the length of the catheter (ManoScan ESO; Given Imaging, Yoqneam, Israel). We evaluated the concordance, repeatability, and tolerability of this catheter. We measured resting, cough, and strain maximum urethral closure pressures (MUCPs) using HRM and measured resting MUCPs with water-perfusion side-hole catheter urethral pressure profilometry (UPP) in 37 continent and 28 stress-incontinent subjects. Maneuvers were repeated after moving the HRM catheter along the urethral length to evaluate whether results depend on catheter positioning. Visual analog pain scores evaluated the comfort of HRM compared to UPP. The correlation coefficient for resting MUCPs measured by HRM versus UPP was high (r = 0.79, P rest, cough, and strain with HRM: r = 0.92, 0.89, and 0.89. Mean MUCPs (rest, cough, and strain) were higher in continent than in incontinent subjects (all P continent subjects during cough and strain maneuvers compared to rest. This preliminary study shows that HRM is concordant with standard technology, repeatable, and well tolerated in the urethra. Incontinent women have more impairment of their urethral closure pressures during cough and strain than continent women.

  5. Air charged and microtip catheters cannot be used interchangeably for urethral pressure measurement: a prospective, single-blind, randomized trial.

    Science.gov (United States)

    Zehnder, Pascal; Roth, Beat; Burkhard, Fiona C; Kessler, Thomas M

    2008-09-01

    We determined and compared urethral pressure measurements using air charged and microtip catheters in a prospective, single-blind, randomized trial. A consecutive series of 64 women referred for urodynamic investigation underwent sequential urethral pressure measurements using an air charged and a microtip catheter in randomized order. Patients were blinded to the type and sequence of catheter used. Agreement between the 2 catheter systems was assessed using the Bland and Altman 95% limits of agreement method. Intraclass correlation coefficients of air charged and microtip catheters for maximum urethral closure pressure at rest were 0.97 and 0.93, and for functional profile length they were 0.9 and 0.78, respectively. Pearson's correlation coefficients and Lin's concordance coefficients of air charged and microtip catheters were r = 0.82 and rho = 0.79 for maximum urethral closure pressure at rest, and r = 0.73 and rho = 0.7 for functional profile length, respectively. When applying the Bland and Altman method, air charged catheters gave higher readings than microtip catheters for maximum urethral closure pressure at rest (mean difference 7.5 cm H(2)O) and functional profile length (mean difference 1.8 mm). There were wide 95% limits of agreement for differences in maximum urethral closure pressure at rest (-24.1 to 39 cm H(2)O) and functional profile length (-7.7 to 11.3 mm). For urethral pressure measurement the air charged catheter is at least as reliable as the microtip catheter and it generally gives higher readings. However, air charged and microtip catheters cannot be used interchangeably for clinical purposes because of insufficient agreement. Hence, clinicians should be aware that air charged and microtip catheters may yield completely different results, and these differences should be acknowledged during clinical decision making.

  6. Urethral Closure Pressure at Stress: A Predictive Measure for the Diagnosis and Severity of Urinary Incontinence in Women

    Directory of Open Access Journals (Sweden)

    Anne-Cécile Pizzoferrato

    2017-06-01

    Full Text Available Purpose Maintaining urinary continence at stress requires a competent urethral sphincter and good suburethral support. Sphincter competence is estimated by measuring the maximal urethral closure pressure at rest. We aimed to study the value of a new urodynamic measure, the urethral closure pressure at stress (s-UCP, in the diagnosis and severity of female stress urinary incontinence (SUI. Methods A total of 400 women without neurological disorders were included in this observational study. SUI was diagnosed using the International Continence Society definition, and severity was assessed using a validated French questionnaire, the Mesure du Handicap Urinaire. The perineal examination consisted of rating the strength of the levator ani muscle (0–5 and an assessment of bladder neck mobility using point Aa (cm. The urodynamic parameters were maximal urethral closure pressure at rest, s-UCP, Valsalva leak point pressure (cm H2O, and pressure transmission ratio (%. Results Of the women, 358 (89.5% were diagnosed with SUI. The risk of SUI significantly increased as s-UCP decreased (odds ratio [OR], 0.92; 95% confidence interval, 0.88–0.98. The discriminative value of the measure was good for the diagnosis of SUI (area under curve>0.80. s-UCP values less than or equal to 20 cm H2O had a sensitivity of 73.1% and a specificity of 93.0% for predicting SUI. The association between s-UCP and SUI severity was also significant. Conclusions s-UCP is the most discriminative measure that has been identified for the diagnosis of SUI. It is strongly inversely correlated with the severity of SUI. It appears to be a specific SUI biomarker reflecting both urethral sphincter competence and urethral support.

  7. Distributed pressure sensors for a urethral catheter.

    Science.gov (United States)

    Ahmadi, Mahdi; Rajamani, Rajesh; Timm, Gerald; Sezen, A S

    2015-01-01

    A flexible strip that incorporates multiple pressure sensors and is capable of being fixed to a urethral catheter is developed. The urethral catheter thus instrumented will be useful for measurement of pressure in a human urethra during urodynamic testing in a clinic. This would help diagnose the causes of urinary incontinence in patients. Capacitive pressure sensors are fabricated on a flexible polyimide-copper substrate using surface micromachining processes and alignment/assembly of the top and bottom portions of the sensor strip. The developed sensor strip is experimentally evaluated in an in vitro test rig using a pressure chamber. The sensor strip is shown to have adequate sensitivity and repeatability. While the calibration factors for the sensors on the strip vary from one sensor to another, even the least sensitive sensor has a resolution better than 0.1 psi.

  8. The urethral closure function in continent and stress urinary incontinent women assessed by urethral pressure reflectometry.

    Science.gov (United States)

    Saaby, Marie-Louise

    2014-02-01

    Stress urinary incontinence (SUI) occurs when the bladder pressure exceeds the urethral pressure in connection with physical effort or exertion or when sneezing or coughing and depends both on the strength of the urethral closure function and the abdominal pressure to which it is subjected. The urethral closure function in continent women and the dysfunction causing SUI are not known in details. The currently accepted view is based on the concept of a sphincteric unit and a support system. Our incomplete knowledge relates to the complexity of the closure apparatus and to inadequate assessment methods which so far have not provided robust urodynamic diagnostic tools, severity measures, or parameters to assess outcome after intervention. Urethral Pressure Reflectometry (UPR) is a novel method that measures the urethral pressure and cross-sectional area (by use of sound waves) simultaneously. The technique involves insertion of only a small, light and flexible polyurethane bag in the urethra and therefore avoids the common artifacts encountered with conventional methods. The UPR parameters can be obtained at a specific site of the urethra, e.g. the high pressure zone, and during various circumstances, i.e. resting and squeezing. During the study period, we advanced the UPR technique to enable faster measurement (within 7 seconds by the continuous technique) which allowed assessment during increased intra-abdominal pressure induced by physical straining. We investigated the urethral closure function in continent and SUI women during resting and straining by the "fast" UPR technique. Thereby new promising urethral parameters were provided that allowed characterization of the closure function based on the permanent closure forces (primarily generated by the sphincteric unit, measured by the Po-rest) and the adjunctive closure forces (primarily generated by the support system, measured by the abdominal to urethral pressure impact ratio (APIR)). The new parameters enabled

  9. Comparison of urethral pressure profilometry and contrast radiography in the diagnosis of incompetence of the urethral sphincter mechanism in bitches

    International Nuclear Information System (INIS)

    Gregory, S.P.; Cripps, P.J.; Holt, P.E.

    1996-01-01

    Three diagnostic indicators of urethral sphincter mechanism incompetence were compared in 25 continent and 25 incontinent anaesthetised bitches: the resting urethral pressure profile, the stressed urethral pressure profile and the radiographic position of the bladder neck. Logistic regression indicated that the best predictor of continence status was the stressed urethral pressure profile as assessed by the percentage of negative peaks extending below the resting intravesical pressure; it classified 43 of the 50 dogs correctly. The radiographic position of the bladder neck was a better predictor of continence than either the measurement of functional profile length or the maximum urethral closure pressure from the resting urethral pressure profile, whether alone or in combination. By combining the percentage of negative peaks on the stressed profile with the position of the bladder neck, 46 of the 50 dogs were classified correctly. Cut-off values for the percentage of negative peaks on the stressed urethral pressure profile, and for the radiographic position of the bladder neck are suggested for use in evaluating incontinent bitches in clinical practice

  10. A faster urethral pressure reflectometry technique for evaluating the squeezing function

    DEFF Research Database (Denmark)

    Klarskov, Niels; Saaby, Marie-Louise; Lose, Gunnar

    2013-01-01

    Abstract Objective. Urethral pressure reflectometry (UPR) has shown to be superior in evaluating the squeeze function compared to urethral pressure profilometry. The conventional UPR measurement (step method) required up to 15 squeezes to provide one measure of the squeezing opening pressure...

  11. Measurement of urethral closure function in women with stress urinary incontinence

    DEFF Research Database (Denmark)

    Klarskov, N; Scholfield, D; Soma, K

    2009-01-01

    , double-blind, placebo controlled, crossover study 17 women with stress urinary incontinence or mixed urinary incontinence received 4 mg esreboxetine or placebo for 7 to 9 days followed by a washout period before crossing over treatments. Urethral pressure reflectometry and urethral pressure profilometry......, and had a positive and clinically relevant effect on urethral closure function and symptoms of stress urinary incontinence....... esreboxetine patients had significantly fewer incontinence episodes and reported a treatment benefit (global impression of change) compared to placebo. CONCLUSIONS: The opening pressure measured with urethral pressure reflectometry was less variable compared to the parameters measured with urethral pressure...

  12. The effect of single oral doses of duloxetine, reboxetine, and midodrine on the urethral pressure in healthy female subjects, using urethral pressure reflectometry

    DEFF Research Database (Denmark)

    Klarskov, Niels; Cerneus, Dirk; Sawyer, William

    2018-01-01

    AIMS: To evaluate the effect on urethral pressure of reference drugs known to reduce stress urinary incontinence symptoms by different effect size and mechanisms of action on urethral musculature under four test conditions in healthy female subjects using urethral pressure reflectometry. METHODS......: Healthy females aged 18-55 years were recruited by advertising for this phase 1, single site, placebo-controlled, randomized, four-period, crossover study. The interventions were single oral doses of 10 mg Midodrine, 80 mg Duloxetine, 12 mg Reboxetine, and placebo. The endpoints were the opening urethral...... pressure measured in each period at four time points (predose and 2, 5.5, and 9 h after dosing). RESULTS: Twenty-nine females were enrolled; 25 randomized and 24 completed the study. The opening urethral pressure was higher in all measurements with filled bladder compared with empty bladder, and during...

  13. Urethral pressure reflectometry before and after tension-free vaginal tape

    DEFF Research Database (Denmark)

    Saaby, Marie-Louise; Klarskov, Niels; Lose, Gunnar

    2012-01-01

    Urethral pressure reflectometry (UPR) is a new method for measuring pressure and cross-sectional area in the urethra. Our aim was to investigate if the UPR parameters at rest and during squeeze were unchanged after TVT....

  14. Urethral pressure reflectometry during intra-abdominal pressure increase—an improved technique to characterize the urethral closure function in continent and stress urinary incontinent women

    DEFF Research Database (Denmark)

    Saaby, Marie-Louise; Klarskov, Niels; Lose, Gunnar

    2013-01-01

    to assess the urethral closure function by urethral pressure reflectometry (UPR) during intra-abdominal pressure-increase in SUI and continent women.......to assess the urethral closure function by urethral pressure reflectometry (UPR) during intra-abdominal pressure-increase in SUI and continent women....

  15. Urethral pressure reflectometry in women with pelvic organ prolapse

    DEFF Research Database (Denmark)

    Khayyami, Yasmine; Lose, Gunnar; Klarskov, Niels

    2017-01-01

    at an abdominal pressure of 50 cmH2O (PO-Abd 50). UPR can help identify women with POP at risk of postoperative de novo SUI. The aim of this study was to investigate the reproducibility of UPR in women with POP. METHODS: Women with anterior or posterior vaginal wall prolapse were recruited for this prospective......INTRODUCTION AND HYPOTHESIS: The mechanism of continence in women with pelvic organ prolapse (POP) before and after surgery remains unknown. Urethral pressure reflectometry (UPR) separates women with stress urinary incontinence (SUI) from continent women by measuring urethral opening pressure...... studies to help reveal urodynamic features predictive of postoperative de novo SUI in women with POP....

  16. A Method for Recording Urethral Pressure Profiles in Female Rats.

    Directory of Open Access Journals (Sweden)

    Shengfei Xu

    Full Text Available Urethral pressure profile (UPP and leak-point pressure (LPP measurements as well as external urethral sphincter (EUS electromyography (EMG and videourodynamic analyses are the primary methods for evaluating urethral function in humans. However, UPP recording in female rats, a widely used animal model, is challenging due to their small body sizes. This study reports a novel method for recording UPP in female rats.Seventeen anesthetized female rats were studied. LPP data for 14 rats were included. The other 3 rats were excluded because of death or abnormal urogenital organs. UPP curves were recorded using a modified water-perfusion catheter system, with the lateral hole facing the 3-, 6-, 9-, and 12-o'clock positions in a randomized sequence. LPP, functional urethral length (FUL and maximum urethral closure pressure (MUCP were analyzed.The mean LPP was 64.39 ± 20.29 cm H2O. The mean FUL and MUCP values at the 3-, 6-, 9-, and 12-o'clock positions were 12.90 ± 1.20, 16.70 ± 1.95, 13.90 ± 2.42, and 11.60 ± 0.97 mm, respectively, and 38.70 ± 11.85, 33.90 ± 11.82, 37.40 ± 11.95, and 71.90 ± 23.01 cm H2O, respectively. The FUL at the 6-o'clock position and MUCP at the 12-o'clock position were significantly greater than those at the other 3 positions. The FUL and MUCP of repeated UPP recordings were not significantly different than those of the first recordings.UPP recording using a modified method based on a water-perfusion catheter system is feasible and replicable in female rats. It produces UPP curves that sensitively and appreciably reflect detailed pressure changes at different points within the urethra and thus provides opportunity to evaluate urethral structures, especially the urethral sphincter, in detail. These results may enhance the utility of female rat models in research of urinary sphincter mechanisms.

  17. Urethral pressure reflectometry, a novel technique for simultaneous recording of pressure and cross-sectional area in the prostatic urethra

    DEFF Research Database (Denmark)

    Aagaard, Mikael; Klarskov, Niels; Sønksen, Jens

    2014-01-01

    OBJECTIVE: Urethral pressure reflectometry (UPR) was introduced in 2005, for simultaneous measurement of pressure and cross-sectional area in the female urethra. It has shown to be more reproducible than conventional pressure measurement. Recently, it has been tested in the anal canal and the pro......OBJECTIVE: Urethral pressure reflectometry (UPR) was introduced in 2005, for simultaneous measurement of pressure and cross-sectional area in the female urethra. It has shown to be more reproducible than conventional pressure measurement. Recently, it has been tested in the anal canal...... version of Prostate Symptom Score, flow rate, residual urine measurements, transrectal ultrasound, urethral pressure profilometry and visual analogue scale (Discomfort). UPR parameters measured were opening and closing pressure, opening and closing elastance and hysteresis, from the bladder neck...

  18. Urethral pressure reflectometry during intra-abdominal pressure increase-an improved technique to characterize the urethral closure function in continent and stress urinary incontinent women.

    Science.gov (United States)

    Saaby, Marie-Louise; Klarskov, Niels; Lose, Gunnar

    2013-11-01

    to assess the urethral closure function by urethral pressure reflectometry (UPR) during intra-abdominal pressure-increase in SUI and continent women. Twenty-five urodynamically proven SUI women and eight continent volunteer women were assessed by ICIQ-SF, pad-weighing test, incontinence diary, and UPR. UPR was conducted during resting and increased intra-abdominal pressure (P(Abd)) by straining. Related values of P(Abd) and urethral opening pressure (P(o)) were plotted into an abdomino-urethral pressuregram. Linear regression of the values was conducted, and the slope of the line ("APIR") and the intercept with the y-axis found. By the equation of the line, Po was calculated for various values of P(Abd), for example, 50 cm H2O (P(o-Abd 50)). The resting P(o) (P(o-rest)) and APIR, respectively, significantly differed in SUI and continent women but could not separate the two groups. The urethral closure equation (UCE) based on P(o-rest) and APIR provided a more detailed characterization of a woman's closure function based on the permanent closure forces (primarily generated by the urethral sphincteric unit) and the adjunctive closure forces (primarily generated by the support system). P(o-Abd 50) and UCE, respectively, which express the combined permanent and adjunctive closure forces and estimate the efficiency of the closure function, separated SUI and continent women and were highly significantly negatively correlated with ICIQ-SF, pad test, and the number of incontinence episodes. New parameters for characterization of the urethral closure function and possible dysfunctions and its efficiency were provided. P(o-Abd 50) and UCE may be used as diagnostic tests and severity measures. © 2013 Wiley Periodicals, Inc.

  19. Urethral pressure reflectometry; a novel technique for simultaneous recording of pressure and cross-sectional area

    DEFF Research Database (Denmark)

    Aagaard, Mikael; Klarskov, Niels; Sønksen, Jens

    2012-01-01

    Study Type - Diagnostic (case series) Level of Evidence 4 What's known on the subject? and What does the study add? In the 1980s and 1990s, a method for direct measurement of pressure and cross-sectional area in women and men was developed. It was successful in terms of obtaining meaningful results...... reproducible than conventional urethral pressure profilometry, when measuring incontinence in women. In 2010 it was also introduced as a new measuring technique in the anal canal. This study, adds a new and interesting technique to the field of male urodynamics. For the first time, sound waves have been used...... in several studies. But the technique, which was based on the field gradient principle, was never implemented in the clinical setting because of technical limitations. In 2005, urethral pressure reflectometry was introduced as a new technique in female urodynamics. The technique has been shown to be more...

  20. Urethral pressure response patterns induced by squeeze in continent and incontinent women.

    Science.gov (United States)

    Teleman, Pia M; Mattiasson, Anders

    2007-09-01

    Our aim was to compare the urethral pressure response pattern to pelvic floor muscle contractions in 20-27 years old, nulliparous continent women (n = 31) to that of continent (n = 28) and formerly untreated incontinent (n = 59) (53-63 years old) women. These women underwent urethral pressure measurements during rest and repeated pelvic muscle contractions. The response to the contractions was graded 0-4. The young continent women showed a mean urethral pressure response of 2.8, the middle-aged continent women 2.2 (NS vs young continent), and the incontinent women 1.5 (p continent, p continent). Urethral pressures during rest were significantly higher in the younger women than in both groups of middle-aged women. The decreased ability to increase urethral pressure on demand seen in middle-aged incontinent women compared to continent women of the same age as well as young women seems to be a consequence of a neuromuscular disorder rather than of age.

  1. Analysis of pressure-flow data in terms of computer-derived urethral resistance parameters

    NARCIS (Netherlands)

    R. van Mastrigt (Ron); M. Kranse

    1995-01-01

    textabstractThe simultaneous measurement of detrusor pressure and flow rate during voiding is at present the only way to measure or grade infravesical obstruction objectively. Numerous methods have been introduced to analyze the resulting data. These methods differ in aim (measurement of urethral

  2. In vivo measurement of urethral dose profiles

    International Nuclear Information System (INIS)

    Toye, W.C.; Royal Melbourne Institute of Technology,; Duchesne, G.M.; Das, K.R.; Cee, A.; Mameghan, H.; Johnston, P.N.

    2001-01-01

    Full text: Quality assurance becomes a critical requirement when radiographs are routinely used in planning of treatments. In HDR prostate brachytherapy, the surrounding organs at risk of complications are the bladder and the rectum. However, of particular concern is the urethra that runs centrally through the prostate gland, as an unavoidably high dose can occur in the central region in order to achieve a minimum peripheral dose to a small target volume. Although high urethral doses have previously been related to increased urinary symptoms, some recent studies have not found such a correlation. The aim of this study was firstly, to identify dosimetric indicators of urethral morbidity following HDR prostate brachytherapy (4F x of 5.0 Gy), and secondly, to test the validity of calculated dose values. The in vivo measurements utilised a TLD (LiF:Mg,Ti) train formed by loading eight TLD rods alternating with 1,0 cm brass spacers into a fine plastic flexible tube. The length and diameter of plastic tubing was approximately 45cm and 0.15cm respectively, while the train length was 11.8 cm from the tip of the tube. The TLD train was placed into the central lumen of an 18 F three-way urethral catheter prior to its insertion. Significant urinary morbidity was defined prospectively as a score of a total of 3 or more points for severity from 5 symptoms categories. The five symptoms evaluated were hesitancy, frequency/nocturia, dysuria, haematuria and incontinence. The introduction of in vivo measurements to enhance the existing dosimetric analysis may be required to fully test the quantitative relationships (e.g. dose-volume ratios). Placement of TLDs within the urethra results in measurements whose accuracy is unaffected by internal organ motion as the hollow urethra must move with the prostate. The dose recorded by the TLDs is determined independently of the predictive algorithm used by the treatment planning system, and prostate location errors (e.g. due to image

  3. Urethritis

    Science.gov (United States)

    ... urethritis. Organisms—such as Neisseria gonorrhoeae , which causes gonorrhea —can spread to the urethra during sexual intercourse ... Sometimes people have no symptoms. In men, when gonorrhea or chlamydia is the cause, there is usually ...

  4. Analysis of pressure-flow data in terms of computer-derived urethral resistance parameters.

    Science.gov (United States)

    van Mastrigt, R; Kranse, M

    1995-01-01

    The simultaneous measurement of detrusor pressure and flow rate during voiding is at present the only way to measure or grade infravesical obstruction objectively. Numerous methods have been introduced to analyze the resulting data. These methods differ in aim (measurement of urethral resistance and/or diagnosis of obstruction), method (manual versus computerized data processing), theory or model used, and resolution (continuously variable parameters or a limited number of classes, the so-called monogram). In this paper, some aspects of these fundamental differences are discussed and illustrated. Subsequently, the properties and clinical performance of two computer-based methods for deriving continuous urethral resistance parameters are treated.

  5. Signal processing in urodynamics: towards high definition urethral pressure profilometry.

    Science.gov (United States)

    Klünder, Mario; Sawodny, Oliver; Amend, Bastian; Ederer, Michael; Kelp, Alexandra; Sievert, Karl-Dietrich; Stenzl, Arnulf; Feuer, Ronny

    2016-03-22

    Urethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI) which is a significant medical, social, and economic problem. Low spatial pressure resolution, common occurrence of artifacts, and uncertainties in data location limit the diagnostic value of UPP. To overcome these limitations, high definition urethral pressure profilometry (HD-UPP) combining enhanced UPP hardware and signal processing algorithms has been developed. In this work, we present the different signal processing steps in HD-UPP and show experimental results from female minipigs. We use a special microtip catheter with high angular pressure resolution and an integrated inclination sensor. Signals from the catheter are filtered and time-correlated artifacts removed. A signal reconstruction algorithm processes pressure data into a detailed pressure image on the urethra's inside. Finally, the pressure distribution on the urethra's outside is calculated through deconvolution. A mathematical model of the urethra is contained in a point-spread-function (PSF) which is identified depending on geometric and material properties of the urethra. We additionally investigate the PSF's frequency response to determine the relevant frequency band for pressure information on the urinary sphincter. Experimental pressure data are spatially located and processed into high resolution pressure images. Artifacts are successfully removed from data without blurring other details. The pressure distribution on the urethra's outside is reconstructed and compared to the one on the inside. Finally, the pressure images are mapped onto the urethral geometry calculated from inclination and position data to provide an integrated image of pressure distribution, anatomical shape, and location. With its advanced sensing capabilities, the novel microtip catheter collects an unprecedented amount of urethral pressure data. Through sequential signal processing steps, physicians are provided with

  6. Effect of fesoterodine on urethral closure function in women with stress urinary incontinence assessed by urethral pressure reflectometry

    DEFF Research Database (Denmark)

    Klarskov, Niels; Darekar, Amanda; Scholfield, David

    2014-01-01

    INTRODUCTION AND HYPOTHESIS: The aim was to evaluate, using urethral pressure reflectometry (UPR), the effect of fesoterodine on urethral function in women with stress urinary incontinence (SUI). METHODS: Women aged 18 to 65 years were eligible for this randomised, double-blind, placebo...... significant differences were seen between fesoterodine 4 mg or fesoterodine 8 mg and placebo in opening urethral pressure (primary endpoint) or other UPR endpoints. No statistically significant differences were seen between either fesoterodine dose and placebo in the change from baseline in the bladder diary...... variables (total urinary incontinence, SUI, or urgency urinary incontinence episodes per 24 h). Adverse events were reported by 8 participants taking fesoterodine 4 mg, 17 taking fesoterodine 8 mg, and 8 taking placebo. CONCLUSIONS: Fesoterodine did not affect urethral pressure or significantly decrease...

  7. The urethral closure function in continent and stress urinary incontinent women assessed by urethral pressure reflectometry

    DEFF Research Database (Denmark)

    Saaby, Marie-Louise

    2014-01-01

    , the parameters showed highly significant negative correlation with ICIQ-SF, pad test and the number of incontinence episodes per week and are therefore valid as urodynamic severity measures. UPR in SUI women before and after TVT demonstrated a more efficient urethral closure function after the operation. The Po......-rest was unchanged suggesting that the sphincteric unit was virtually unaltered and hence the permanent closure forces unchanged. However, the resting opening elastance increased by 18% indicating that at the resting state the TVT somewhat improves the closure function by providing increased resistance against...... the dilation of the urethra, which probably explains the decreased maximum urine flow rate found after TVT in this and previous studies. The APIR increased in all patients after TVT suggesting that the support system was re-established and thus the adjunctive closure forces improved, regardless of the type...

  8. Urethral pressure reflectometry in women with pelvic organ prolapse: a study of reproducibility.

    Science.gov (United States)

    Khayyami, Yasmine; Lose, Gunnar; Klarskov, Niels

    2017-05-01

    The mechanism of continence in women with pelvic organ prolapse (POP) before and after surgery remains unknown. Urethral pressure reflectometry (UPR) separates women with stress urinary incontinence (SUI) from continent women by measuring urethral opening pressure at an abdominal pressure of 50 cmH 2 O (P O-Abd 50 ). UPR can help identify women with POP at risk of postoperative de novo SUI. The aim of this study was to investigate the reproducibility of UPR in women with POP. Women with anterior or posterior vaginal wall prolapse were recruited for this prospective, observational study from our outpatient clinic. The women were examined with UPR on two occasions. Measurements were done at rest, and during squeezing and straining. Statistical analyses were performed using SAS 9.4. A Bland-Altman analysis with limits of agreement and coefficients of variation was used to determine the level of agreement between measurements. Paired t tests were used to estimate the difference; a two-tailed P value of rest or during squeezing or in the values of P O-Abd 50 . P O-Abd 50 showed limits of agreement of 15.3 cmH 2 O and a coefficient of variation of 9.9 %. UPR was found to be a highly reproducible method in women with POP. UPR may be used in future studies to help reveal urodynamic features predictive of postoperative de novo SUI in women with POP.

  9. Vaginal Swab Test Compared With the Urethral Q-tip Test for Urethral Mobility Measurement: A Randomized Controlled Trial.

    Science.gov (United States)

    Meyer, Isuzu; Szychowski, Jeff M; Illston, Jana D; Parden, Alison M; Richter, Holly E

    2016-02-01

    To assess whether use of a vaginal cotton-tipped swab is equivalent to the standard Q-tip test regarding urethral mobility. Secondarily, to examine whether both tests agree in hypermobility diagnosis, discomfort level, and patients' preference. In this randomized crossover trial, women with stress urinary incontinence without prolapse beyond the hymen were randomized to undergo either a vaginal or urethral mobility test first followed by the alternate approach. The primary outcome was the difference in rotation angle, from resting to maximum strain, between tests. The equivalence margin was ±10°. The secondary outcome was agreement in hypermobility diagnosis using two definitions: 1) maximum straining angle of 30° or greater from the horizontal plane; and 2) rotation angle 30° or greater. Discomfort was assessed using a 0-10 visual analog scale. Using 90% power assuming a standard deviation of 20°, 36 and 139 patients were needed for 10° and 5° equivalence margins, respectively. From January 2014 to March 2015, 140 women were randomized. The mean difference between the two tests was 5.1° (95% confidence interval 3.2-6.9°), meeting the predefined equivalence criteria. In the hypermobility diagnosis, the urethral and vaginal tests had no disagreement using definition 1 (P=.23), whereas the two tests disagreed using definition 2 (P=.03). The urethral approach had a higher discomfort level (Pstandard Q-tip test in measuring urethral mobility with less discomfort and is preferred by patients.

  10. Technical features of the system used to perform multichannel urethral pressure profilometry

    NARCIS (Netherlands)

    Messelink, E. J.; Dobbe, I.; Kools, C.; Dabhoiwala, N. F.; Dijkhuizen, T.; Schneider, P.; Lettinga, K. P.; Kurth, K.

    1997-01-01

    Multichannel Urethral Pressure Profilometry (MCUPP) is a method used to get more information on the pressure distribution within the female urethra. This information may be of value in the diagnostic work up of women with urinary incontinence. Different systems are used for this technique. The pump

  11. Is a sequence of tests during urethral pressure profilometry correlated with symptoms assessment in women?

    Science.gov (United States)

    Valentini, Françoise A; Robain, Gilberte; Marti, Brigitte G

    2012-01-01

    Our purpose was, applying a strictly defined protocol for urethral profilometry, 1) to test the repeatability of same session rest maximum urethral closure pressure (MUCP) and 2) to search for correlation between women complaint and the changes in MUCP value (rest and dynamic tests). A population of 140 consecutive women referred for evaluation of lower urinary tract dysfunction was stratified in 4 groups according with the urinary symptoms: stress, urge, mixed incontinence and continent and in each group in 3 age groups (young, middle age and old). The sequence of tests recorded in supine position was: urethral pressure profile at rest bladder empty, after bladder filling at 250 mL (reference test), stress profile, fatigability (before (rest) and after 10 successive strong coughs), then in standing position. In all groups, there was no significant difference between the two MUCP values at rest bladder filled. In the three incontinent groups, MUCP was higher bladder empty than bladder filled (p rest bladder filled has a good repeatability in individual. However a complex sequence of tests during urethral pressure profilometry remains discussed in middle-age and old age-groups, it allows specifying the stress component of incontinence in young women and the urgency component in all age-groups.

  12. Is a sequence of tests during urethral pressure profilometry correlated with symptoms assessment in women?

    Directory of Open Access Journals (Sweden)

    Françoise A. Valentini

    2012-12-01

    Full Text Available Introduction Our purpose was, applying a strictly defined protocol for urethral profilometry, 1 to test the repeatability of same session rest maximum urethral closure pressure (MUCP and 2 to search for correlation between women complaint and the changes in MUCP value (rest and dynamic tests. Materials and Methods A population of 140 consecutive women referred for evaluation of lower urinary tract dysfunction was stratified in 4 groups according with the urinary symptoms: stress, urge, mixed incontinence and continent and in each group in 3 age groups (young, middle age and old. The sequence of tests recorded in supine position was: urethral pressure profile at rest bladder empty, after bladder filling at 250 mL (reference test, stress profile, fatigability (before (rest and after 10 successive strong coughs, then in standing position. Results In all groups, there was no significant difference between the two MUCP values at rest bladder filled. In the three incontinent groups, MUCP was higher bladder empty than bladder filled (p < 0.05 except in the young sub-group. Stress incontinence led to significant decrease of MUCP during dynamic tests in the young group. MUCP was not modified after fatigability test in women with urge complaint whatever age. Conclusion When recorded following a strictly defined protocol, MUCP at rest bladder filled has a good repeatability in individual. However a complex sequence of tests during urethral pressure profilometry remains discussed in middle-age and old age-groups, it allows specifying the stress component of incontinence in young women and the urgency component in all age-groups.

  13. Evaluating the urethral closure mechanism after pelvic organ prolapse surgery

    DEFF Research Database (Denmark)

    Khayyami, Yasmine

    2017-01-01

    . By measuring urethral opening pressure at an abdominal pressure of 50 mmH2O (PO-Abd 50), it is the only method that has succeeded in distinguishing between women with and without SUI. The overall aim of this thesis was to evaluate the urethral closure mechanism before and after anterior and posterior......, the woman has occult SUI. However, only half of all women with occult SUI actually develop de novo SUI postoperatively and therefore, the usefulness of the test has been questioned. Studies investigating how POP reduction and POP surgery affect the urethral closure mechanism have used conventional urethral...... pressure profilometry, a method that has shown wide overlaps in the results of women with and without SUI. Urethral pressure reflectometry (UPR), a method that assesses the urethral closure mechanism by means of acoustic reflectometry, has proven highly reproducible in women with and without SUI...

  14. Urethral stricture

    Science.gov (United States)

    ... It can also occur after a disease or injury. Rarely, it may be caused by pressure from a growing tumor near the urethra. Other factors that increase the risk for this condition include: Sexually ... Injury to the pelvic area Repeated urethritis Strictures that ...

  15. Assessing the reproducibility of high definition urethral pressure profilometry and its correlation with an air-charged system.

    Science.gov (United States)

    Klünder, Mario; Amend, Bastian; Sawodny, Oliver; Stenzl, Arnulf; Ederer, Michael; Kelp, Alexandra; Sievert, Karl-Dietrich; Feuer, Ronny

    2017-06-01

    Recently, a new urodynamic method for the assessment of stress urinary incontinence called high definition urethral pressure profilometry (HD-UPP) has been introduced. This method combines a novel microtip catheter with advanced signal processing to enable spatial data location and the reconstruction of a pressure image inside the urethra. In order to assess the reproducibility of HD-UPP data, we statistically evaluate HD-UPP datasets and compare them to data from a double balloon air-charged system. Both catheters are used on sedated female minipigs. Data from the microtip catheter are processed through a signal reconstruction algorithm, urodynamic features are extracted, and compared to the air-charged system. Reproducibility of HD-UPP data is assessed by statistically evaluating consecutive, intra-individual datasets. HD-UPP delivers results in agreement with previous comparisons of microtip and air-charged systems. The average deviation of two consecutive, intra-individual pressure images is very low at 7 cm H 2 O. HD-UPP provides physicians with detailed information on the pressure distribution inside the urethra. Through comparison with an air-charged catheter, it is shown that HD-UPP delivers results in agreement with previous studies on the comparison of microtip and air-charged catheters. It provides excellent reproducibility, as the difference between sequentially measured profiles from the same minipig is significantly lower than the one between profiles from different minipigs. © 2016 Wiley Periodicals, Inc.

  16. Outcome of TVT operations in women with low maximum urethral closure pressure.

    Science.gov (United States)

    Moe, Kjartan; Schiøtz, Hjalmar A; Kulseng-Hanssen, Sigurd

    2017-06-01

    (i) To establish whether low maximal urethral closure pressure (MUCP) is associated with a poorer prognosis after TVT-surgery, and if so to establish an MUCP cut-off value for poor outcome. (ii) To characterize the population with a low MUCP. Retrospective analysis of data from 6,646 women with stress/mixed urinary incontinence included in the Norwegian Female Incontinence Registry. Postoperative subjective (degree of satisfaction), objective (leakage on stress test) and composite cure according to preoperative MUCP were analyzed in unadjusted and adjusted analysis. Preoperative variables were compared between women having a low or normal MUCP. Non-parametric tests were used on continuous variables and χ 2 tests on categorical variables. Logistic regression was used for the adjusted analysis. Level of significance: P 20 cm H 2 O. In adjusted analysis MUCP ≤20 cm H 2 O was associated with neither objective, subjective, nor composite failure. Women with MUCP TVT-surgery compared to women with MUCP >20 cm H 2 O after adjusting for preoperative variables. Neurourol. Urodynam. 36:1320-1324, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. A Giant Urethral Calculus.

    Science.gov (United States)

    Sigdel, G; Agarwal, A; Keshaw, B W

    2014-01-01

    Urethral calculi are rare forms of urolithiasis. Majority of the calculi are migratory from urinary bladder or upper urinary tract. Primary urethral calculi usually occur in presence of urethral stricture or diverticulum. In this article we report a case of a giant posterior urethral calculus measuring 7x3x2 cm in a 47 years old male. Patient presented with acute retention of urine which was preceded by burning micturition and dribbling of urine for one week. The calculus was pushed in to the bladder through the cystoscope and was removed by suprapubic cystolithotomy.

  18. Urethral calibre measurements on micturition cystourethrograms in adult males. Pt. 1

    International Nuclear Information System (INIS)

    Manoliu, R.A.

    1982-01-01

    The calibres of six different parts of the urethra were measured on micturition cystourethrograms in 92 normal adult males. The results are graphically displayed as frequency distribution histograms. The narrowest segment of the visualized urethra appeared to be the membranous part in 89 per cent of the cases. In the rest of the cases more distal regions were less distended than the membranous urethra. The bladder neck was always wider than the membranous part. Comparison of the diameters of the same segments measured in different planes suggest that during micturition the cross-sectional shape of the urethral tube is round. (orig.)

  19. Urethral Injuries

    Science.gov (United States)

    ... the bladder and the urethra ( cystoscopy ). Treatment Bladder drainage tube Sometimes surgery (to repair urethral tears) For urethral bruises that do not result in any leakage of urine, a doctor can place a catheter ... days to drain the urine while the urethra heals. For urethral ...

  20. Urethrotonography - a radiological and manometrical combination technique to diagnose urinary stress incontinance in comparison with urethral pressure profile recording

    International Nuclear Information System (INIS)

    Wess, H.

    1982-01-01

    The study described here was carried out in order to gain more insight into the pathogenesis of urinary stress incontinance and the related urethrovesical functions. The pathophysiological changes in the urogenital tract that are associated with urinary stress incontinance are described just as well as the clinical symptoms and signs differentiating the individual forms of incontinance from each other. Account is further taken of the various manometrical and radiological techniques used in the diagnosis of urinary stress incontinance. In this study, which included a total of 100 patients, comparative evaluations were made of the pressure behaviour of the bladder during the filling-up phase and the closing mechanism of the urethra both at rest and under stress using the following procedures: - Method developed by Brown and Wickham for urethral pressure profile recording; visualisation of the bladder and urethra with the aid of X-rays and a balloon catheter especially developed by us. The latter technique may help to solve the problems usually arising when given morphological factors are to be connected with certain medical views or theories concerning the vesical and urethral functions as well as the pathogenesis of urinary stress incontinance. It may thus enable more straightforward diagnosis to be made. (TRV) [de

  1. Urethral trauma

    International Nuclear Information System (INIS)

    Carrington, B.M.; Hricak, H.; Dixon, C.; McAninch, J.W.

    1990-01-01

    This paper evaluates the role of MR imaging in posterior urethral trauma. Fifteen patients with posttraumatic membranous urethral strictures underwent prospective MR imaging with a 1.5-T unit before open urethroplasty. All patients had transaxial T1-weighted (500/20) and T2-weighted (2,500/70) spin-echo images and T2-weighted sagittal and coronal images (matrix, 192 x 256; section thickness, 4 mm with 20% gap). Conventional retrograde and cystourethrography were performed preoperatively. Compared with conventional studies, MR imaging defined the length and location of the urethral injury and provided additional information regarding the direction and degree of prostatic and urethral dislocation

  2. Measuring fluid pressure

    International Nuclear Information System (INIS)

    Lee, A.S.

    1978-01-01

    A method and apparatus are described for measuring the pressure of a fluid having characteristics that make it unsuitable for connection directly to a pressure gauge. The method is particularly suitable for the periodic measurement of the pressure of a supply of liquid Na to Na-lubricated bearings of pumps for pumping Na from a reservoir to the bearing via a filter, the reservoir being contained in a closed vessel containing an inert blanket gas, such as Ar, above the Na. (UK)

  3. Pressure Measurement Systems

    Science.gov (United States)

    1990-01-01

    System 8400 is an advanced system for measurement of gas and liquid pressure, along with a variety of other parameters, including voltage, frequency and digital inputs. System 8400 offers exceptionally high speed data acquisition through parallel processing, and its modular design allows expansion from a relatively inexpensive entry level system by the addition of modular Input Units that can be installed or removed in minutes. Douglas Juanarena was on the team of engineers that developed a new technology known as ESP (electronically scanned pressure). The Langley ESP measurement system was based on miniature integrated circuit pressure-sensing transducers that communicated pressure information to a minicomputer. In 1977, Juanarena formed PSI to exploit the NASA technology. In 1978 he left Langley, obtained a NASA license for the technology, introduced the first commercial product, the 780B pressure measurement system. PSI developed a pressure scanner for automation of industrial processes. Now in its second design generation, the DPT-6400 is capable of making 2,000 measurements a second and has 64 channels by addition of slave units. New system 8400 represents PSI's bid to further exploit the 600 million U.S. industrial pressure measurement market. It is geared to provide a turnkey solution to physical measurement.

  4. Line pressure effects on differential pressure measurements

    International Nuclear Information System (INIS)

    Neff, G.G.; Evans, R.P.

    1982-01-01

    The performance of differential pressure transducers in experimental pressurized water reactor (PWR) systems was evaluated. Transient differential pressure measurements made using a simple calibration proportionality relating differential pressure to output voltage could have large measurement uncertainties. A more sophisticated calibration equation was derived to incorporate the effects of zero shifts and sensitivity shifts as pressure in the pressure sensing line changes with time. A comparison made between the original calibration proportionality equation and the derived compensation equation indicates that potential measurement uncertainties can be reduced

  5. Ultrasonographic evaluation of urethral stricture

    International Nuclear Information System (INIS)

    Kim, Seung Eun; Lee, Hee Jung; Lee, Nam Hee; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun

    1990-01-01

    We studied sonography of saline filled male urethra in 21 cases, who had a urinary symptoms of urethral stricture. There were 11 cases of anterior urethral stricture, 2 cases of stricture with stone, and 8 cases of posterior urethral stricture. Sonography length of urethral stricture was compared with that of retrograde urethrography. The level and length of urethral stricture in sonography and retrograde urethrography compared to surgical findings in 7 out of 21 cases. The average lengths of anterior urethral strictures measured by sonography and retrograde urethroography were 28.15 and 18.75 mm. In cases of operation, the sonographic measurement was confirmed to be more accurate than urethrographic measurement. Sonography is easier to perform, more available in follow up and has no radiation hazard to the testis than X-ray study. Sonography is more accurate to determine the site, length and degree of anterior urethral stricture than X-ray study. As sonographic evaluations concerning posterior urethra stricture is impossible because of angulations of the urethra in posterior urethra, retrograde urethrography is preferable

  6. Ultrasonographic evaluation of urethral stricture

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Eun; Lee, Hee Jung; Lee, Nam Hee; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun [Seoul Red Cross Hospital, Seoul (Korea, Republic of)

    1990-12-15

    We studied sonography of saline filled male urethra in 21 cases, who had a urinary symptoms of urethral stricture. There were 11 cases of anterior urethral stricture, 2 cases of stricture with stone, and 8 cases of posterior urethral stricture. Sonography length of urethral stricture was compared with that of retrograde urethrography. The level and length of urethral stricture in sonography and retrograde urethrography compared to surgical findings in 7 out of 21 cases. The average lengths of anterior urethral strictures measured by sonography and retrograde urethroography were 28.15 and 18.75 mm. In cases of operation, the sonographic measurement was confirmed to be more accurate than urethrographic measurement. Sonography is easier to perform, more available in follow up and has no radiation hazard to the testis than X-ray study. Sonography is more accurate to determine the site, length and degree of anterior urethral stricture than X-ray study. As sonographic evaluations concerning posterior urethra stricture is impossible because of angulations of the urethra in posterior urethra, retrograde urethrography is preferable.

  7. Serial blood pressure measurements

    Directory of Open Access Journals (Sweden)

    N.R. Koehler

    2002-05-01

    Full Text Available The objective of the present investigation was to study the effects of a 60-s interval of venous congestion between two noninvasive measurements of arterial blood pressure (ABP on the fluctuation of ABP, assessed by the standard deviation of the differences between two readings. ABP was measured in 345 successive patients, at rest, four times each. For 269 participants, one pair of readings was obtained with a 60-s interval and the other pair without an interval. For 76 patients, the first pair was read at the same interval, and the second pair had venous congestion interposed and there was no waiting interval. There was no increased ABP oscillation, either when there was no interval between ABP readings, or when venous congestion was interposed compared to pairs of ABP measurements performed with a 60-s interval. There was no increase in ABP oscillations when successive ABP readings were taken without an interval or even with venous congestion interposed. Contrary to the present belief, there seems to be no loss of reliability when blood pressure recordings are taken immediately one after another, in the clinical setting.

  8. Pressure Measurement Sensor

    Science.gov (United States)

    1997-01-01

    FFPI Industries Inc. is the manufacturer of fiber-optic sensors that furnish accurate pressure measurements in internal combustion chambers. Such an assessment can help reduce pollution emitted by these engines. A chief component in the sensor owes its seven year- long development to Lewis Research Center funding to embed optical fibers and sensors in metal parts. NASA support to Texas A&M University played a critical role in developing this fiber optic technology and led to the formation of FFPI Industries and the production of fiber sensor products. The simple, rugged design of the sensor offers the potential for mass production at low cost. Widespread application of the new technology is forseen, from natural gas transmission, oil refining and electrical power generation to rail transport and the petrochemical paper product industry.

  9. Urethral alarm probe for permanent prostate implants

    International Nuclear Information System (INIS)

    Cutajar, D.; Lerch, M.; Takacs, G.

    2008-01-01

    We have developed a urethral dosimetry system for real time dose verification along the urethra during permanent implant prostate brachytherapy. The urethral alarm uses 'spectroscopic dosimetry' to calculate the dose rate along the urethra in real time. The application of spectroscopic dosimetry for the urethral alarm probe was verified using Monte Carlo calculations. In phantom depth dose measurements as well as isotropy measurements were performed to verify the usefulness of the urethra alarm probe as an in vivo real time dosimeter. (author)

  10. TRICHOMONAS URETHRITIS IN MALES

    Science.gov (United States)

    Le Duc, Ector

    1955-01-01

    Trichomonas urethritis in the male should be suspected in all chronic cases of urethritis. The diagnosis is easily established by the hanging-drop method of examining the urethral discharge, or the first-glass urine specimen. Curative treatment is readily accomplished by the use of urethral instillations of Carbarsone suspension using 1 capsule of Carbarsone per ounce of distilled water. PMID:13270111

  11. Preoperative Valsava leak point pressure may not predict outcome of mid-urethral slings: analysis from a randomized controlled trial of retropubic versus transobturator mid-urethral slings

    Directory of Open Access Journals (Sweden)

    Elisabetta Costantini

    2008-02-01

    Full Text Available OBJECTIVE: To test the hypothesis that preoperative Valsalva leak point pressure (VLPP predicts long-term outcome of mid-urethra slings for female stress urinary incontinence (SUI. MATERIALS AND METHODS: One hundred and forty-five patients with SUI were prospectively randomized to two mid-urethra sling treatments: Tension free vaginal tape (TVT or transobturator tape (TOT. They were followed-up at 3, 6, 12 months post-operatively and then annually for the primary outcome variable, i.e. dry or wet and secondary outcome variables such as scores on the urogenital distress inventory (UDI-6 and the impact of incontinence on quality of life (IIQ-7 questionnaire as well as patient satisfaction as scored on a visual analogue scale (VAS. Preoperative VLPP was correlated with primary and secondary outcome variables. RESULTS: Mean follow-ups were 32 + 12 months (range 12-55 for TVT and 31 + 15 months (range 12-61 for TOT. When patients were analyzed according to VLPP stratification, 95 (65.5% patients showed a VLPP > 60 cm H2O and 50 (34.5% patients had a VLPP 60 cm H2O and 72% for those with VLPP 60 cm H2O (82 % vs. 68.9% p of 60 cm H2O, preoperative VLPP was not linked to outcome after TVT or TOT procedures.

  12. Magnetic measurements under pressure

    Czech Academy of Sciences Publication Activity Database

    Zentková, M.; Arnold, Zdeněk; Mihalik, M.; Mihalik, M.; Zentko, A.; Kamarád, Jiří; Mitróová, Z.; Mat`aš, S.

    2006-01-01

    Roč. 57, 8/S (2006), s. 29-32 ISSN 1335-3632 Institutional research plan: CEZ:AV0Z10100521 Keywords : hydrostatic pressure * Prussian blue analogues * AC susceptibility * intermetallic compound * ferromagnetism * errimagnetism Subject RIV: BM - Solid Matter Physics ; Magnetism

  13. Posterior Urethral Strictures

    Directory of Open Access Journals (Sweden)

    Joel Gelman

    2015-01-01

    Full Text Available Pelvic fracture urethral injuries are typically partial and more often complete disruptions of the most proximal bulbar and distal membranous urethra. Emergency management includes suprapubic tube placement. Subsequent primary realignment to place a urethral catheter remains a controversial topic, but what is not controversial is that when there is the development of a stricture (which is usually obliterative with a distraction defect after suprapubic tube placement or urethral catheter removal, the standard of care is delayed urethral reconstruction with excision and primary anastomosis. This paper reviews the management of patients who suffer pelvic fracture urethral injuries and the techniques of preoperative urethral imaging and subsequent posterior urethroplasty.

  14. Posterior Urethral Strictures

    Science.gov (United States)

    Gelman, Joel; Wisenbaugh, Eric S.

    2015-01-01

    Pelvic fracture urethral injuries are typically partial and more often complete disruptions of the most proximal bulbar and distal membranous urethra. Emergency management includes suprapubic tube placement. Subsequent primary realignment to place a urethral catheter remains a controversial topic, but what is not controversial is that when there is the development of a stricture (which is usually obliterative with a distraction defect) after suprapubic tube placement or urethral catheter removal, the standard of care is delayed urethral reconstruction with excision and primary anastomosis. This paper reviews the management of patients who suffer pelvic fracture urethral injuries and the techniques of preoperative urethral imaging and subsequent posterior urethroplasty. PMID:26691883

  15. Pressure measurements in harsh environments

    International Nuclear Information System (INIS)

    Cook, C.W.; Ames, E.S.

    1979-01-01

    A fluid coupled plate (FCP) gage was designed which allows pressure measurements to be made in harsh environments (including debris) using conventional pressure transducers. The pressure transducer is isolated by means of a rigid force plate which is supported by a bellows having one corrugation. This portion of the gage is machined from a single piece of material. The interior of the gage is filled with a phenol fluid which has a low compressibility

  16. LOFT fuel rod pressure measurement

    International Nuclear Information System (INIS)

    Billeter, T.R.

    1979-01-01

    Pressure sensors selected for measuring fuel rod pressure within the LOFT reactor exhibited stable, repeatable operating characteristics during calibrations at temperatures up to 800 0 F and pressures to 2500 psig. All sensors have a nominal sensitivity of .5 millivolts per psi, decreasing monotonically with temperature. Output signal increases linearly with increasing pressure up to 2000 psig. For imposed slow and rapid temperature variations and for pressure applied during these tests, the sensor indicates a pressure at variance with the actual value by up to 15% of reading. However, the imposed temperature rates of change often exceeded the value of -10 0 F/sec. specified for LOFT. The series of tests in an autoclave permit creation of an environment most closely resembling sensor operating conditions within LOFT. For multiple blowdowns and for longtime durations the sensor continued to provide pressure-related output signals. For temperature rates up to -87 0 F/sec, the indicated pressure measurement error remained less than 13% of reading. Adverse effects caused by heating the 1/16 inch O.D. signal cable to 800 0 F contributed only insignificantly to the noted pressure measurement error

  17. Urethral hydrodistension for management of urethral hypoplasia in prune belly syndrome: long-term results.

    Science.gov (United States)

    Kajbafzadeh, Abdol-Mohammad; Rasouli, Mohammad Reza; Dianat, SeyedSaeid; Nezami, Behtash G; Mahboubi, Amir Hassan; Sina, Alireza

    2010-11-01

    The aim of the study was to evaluate the efficacy and safety of urethral hydrodistension for management of urethral hypoplasia in prune belly syndrome (PBS). During a 10-year period, 7 infants with PBS and urethral hypoplasia presented either with open urachus or surgically created urinary diversion referred to our hospital. Five milliliters of normal saline was pushed via a 22-gauge plastic angiocatheter into the urethra with simultaneous finger pressure on the perineum to occlude the proximal urethra that was repeated with higher volumes of the solution (up to 20 mL). The procedure was continued until a 6F or 8F feeding tube catheter confirmed the urethral patency. Hydrodistension was repeated in 3-month intervals till complete patency was confirmed by imaging. Median age of the infants was 6 (1-8) months. All urethral hydrodistension were successful after 1 to 3 sessions. Follow-up imaging studies showed significant improvement in all patients except one. Natural and surgically created urinary diversions were closed in 6 infants. The hydrodistension create an equal and constant pressure into the urethral wall without any urethral damage. This technique can be considered along with the other available methods for management of urethral hypoplasia in selected cases of PBS. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. Measurement of fast transient pressures

    International Nuclear Information System (INIS)

    Procaccia, Henri

    1978-01-01

    The accuracy, reliability and sensitivity of a pressure transducers define its principal static characteristics. When the quantity measured varies with time, the measurement carries a dynamic error and a delay depending on the frequency of this variation. Hence, when fast pressure changes in a fluid have to be determined, different kinds of pressure transducers can be used depending on their inherent dynamic characteristics which must be compared with those of the transient phenomenon to be analysed. The text describes the pressure transducers generally employed in industry for analysing such phenomenon and gives two practical applications developed in the EDF: the first submits the measurements and results of pump cavitation tests carried out at the Vitry II EDF power station; the second deals with hammer blows particularly noticed in nuclear power stations and required the use of transducers of exceptionally high performance such as strain gauge transducers and piezoelectric transducers (response time within 1m sec.) [fr

  19. Endoscopic urethral realignment of traumatic urethral disruption: A monocentric experience

    Directory of Open Access Journals (Sweden)

    Hamed Mohamed El Darawany

    2018-01-01

    Conclusions: Endoscopic primary realignment of posterior urethral rupture is less invasive and a safer procedure, without pelvic hemorrhage or additional injuries. It has low incidence of severe urethral stricture and avoids the need for delayed open urethral reconstruction.

  20. Comparison of urethral diameters for calculating the urethral dose after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Matsuo, Masayuki; Nakano, Masahiro; Kubota, Yasuaki; Maeda, Sunaho; Ohtakara, Kazuhiro; Deguchi, Takashi; Hoshi, Hiroaki

    2007-01-01

    No studies have yet evaluated the effects of a dosimetric analysis for different urethral volumes. We therefore evaluated the effects of a dosimetric analysis to determine the different urethral volumes. This study was based on computed tomography/magnetic resonance imaging (CT/MRI) combined findings in 30 patients who had undergone prostate brachytherapy. Postimplant CT/MRI scans were performed 30 days after the implant. The urethra was contoured based on its diameter (8, 6, 4, 2, and 0 mm). The total urethral volume-in cubic centimeters [UrV150/200 (cc)] and percent (UrV150%/200%), of the urethra receiving 150% or 200% of the prescribed dose-and the doses (UrD90/30/5) in Grays to 90%, 30%, and 5% of the urethral volume were measured based on the urethral diameters. The UrV150 (cc) and UrD30 were statistically different between the of 8-, 6-, 4-, 2-, and 0-mm diameters, whereas the UrD5 was statistically different only between the 8-, 6-, and 4-mm diameters. Especially for UrD5, there was an approximately 40-Gy difference between the mean values for the 8- and 0-mm diameters. We recommend that the urethra should be contoured as a 4- to 6-mm diameter circle or one side of a triangle of 5-7 mm. By standardizing the urethral diameter, the urethral dose will be less affected by the total urethral volume. (author)

  1. Automated Office Blood Pressure Measurement.

    Science.gov (United States)

    Myers, Martin G

    2018-04-01

    Manual blood pressure (BP) recorded in routine clinical practice is relatively inaccurate and associated with higher readings compared to BP measured in research studies in accordance with standardized measurement guidelines. The increase in routine office BP is the result of several factors, especially the presence of office staff, which tends to make patients nervous and also allows for conversation to occur. With the disappearance of the mercury sphygmomanometer because of environmental concerns, there is greater use of oscillometric BP recorders, both in the office setting and elsewhere. Although oscillometric devices may reduce some aspects of observer BP measurement error in the clinical setting, they are still associated with higher BP readings, known as white coat hypertension (for diagnosis) or white coat effect (with treated hypertension). Now that fully automated sphygmomanometers are available which are capable of recording several readings with the patient resting quietly, there is no longer any need to have office staff present when BP is being recorded. Such readings are called automated office blood pressure (AOBP) and they are both more accurate than conventional manual office BP and not associated with the white coat phenomena. AOBP readings are also similar to the awake ambulatory BP and home BP, both of which are relatively good predictors of cardiovascular risk. The available evidence suggests that AOBP should now replace manual or electronic office BP readings when screening patients for hypertension and also after antihypertensive drug therapy is initiated. Copyright © 2018. The Korean Society of Cardiology.

  2. Magnetic resonance imaging in assessment of stress urinary incontinence in women: Parameters differentiating urethral hypermobility and intrinsic sphincter deficiency.

    Science.gov (United States)

    Macura, Katarzyna Jadwiga; Thompson, Richard Eugene; Bluemke, David Alan; Genadry, Rene

    2015-11-28

    To define the magnetic resonance imaging (MRI) parameters differentiating urethral hypermobility (UH) and intrinsic sphincter deficiency (ISD) in women with stress urinary incontinence (SUI). The static and dynamic MR images of 21 patients with SUI were correlated to urodynamic (UD) findings and compared to those of 10 continent controls. For the assessment of the urethra and integrity of the urethral support structures, we applied the high-resolution endocavitary MRI, such as intraurethral MRI, endovaginal or endorectal MRI. For the functional imaging of the urethral support, we performed dynamic MRI with the pelvic phased array coil. We assessed the following MRI parameters in both the patient and the volunteer groups: (1) urethral angle; (2) bladder neck descent; (3) status of the periurethral ligaments, (4) vaginal shape; (5) urethral sphincter integrity, length and muscle thickness at mid urethra; (6) bladder neck funneling; (7) status of the puborectalis muscle; (8) pubo-vaginal distance. UDs parameters were assessed in the patient study group as follows: (1) urethral mobility angle on Q-tip test; (2) Valsalva leak point pressure (VLPP) measured at 250 cc bladder volume; and (3) maximum urethral closure pressure (MUCP). The UH type of SUI was defined with the Q-tip test angle over 30 degrees, and VLPP pressure over 60 cm H2O. The ISD incontinence was defined with MUCP pressure below 20 cm H2O, and VLPP pressure less or equal to 60 cm H2O. We considered the associations between the MRI and clinical data and UDs using a variety of statistical tools to include linear regression, multivariate logistic regression and receiver operating characteristic (ROC) analysis. All statistical analyses were performed using STATA version 9.0 (StataCorp LP, College Station, TX). In the incontinent group, 52% have history of vaginal delivery trauma as compared to none in control group (P continent volunteers and incontinent patients in body habitus as assessed by the body mass

  3. Congenital anterior urethral diverticulum

    International Nuclear Information System (INIS)

    Jung, Hyun Sub; Chung, Young Sun; Suh, Chee Jang; Won, Jong Jin

    1985-01-01

    Two cases of congenital anterior urethral diverticular which have occurred in a 4 year old and one month old boy are presented. Etiology, diagnostic procedures, and its clinical results are briefly reviewed

  4. Urethral diverticulum in pregnancy

    Directory of Open Access Journals (Sweden)

    Qiao-Xuan Xie

    2015-05-01

    Full Text Available Urethral diverticulum is rare in pregnancy. There is no clear guideline on the management of urethral diverticulum in pregnancy, but most cases were managed conservatively. We report a case of urethral diverticulum in a primigravida woman, who presented with anterior vaginal swelling at 14 weeks of gestation. She was managed conservatively and the cyst (approximately 8 cm × 13 cm was aspirated during the early stage of labor. However her labor did not progress during the second stage, which resulted in an emergency cesarean section. She underwent diverticulectomy at 1 month postpartum because of the recurrence of the swelling and persistent discomfort. We believe that her dystocia may have been caused by factors other than the diverticulum. As previously described in literature, we concluded that, even in pregnant women with a large urethral diverticulum, vaginal delivery can still be considered with prior aspiration during the early stage of labor.

  5. Pressures Detector Calibration and Measurement

    CERN Document Server

    AUTHOR|(CDS)2156315

    2016-01-01

    This is report of my first and second projects (of 3) in NA61. I did data taking and analysis in order to do calibration of pressure detectors and verified it. I analyzed the data by ROOT software using the C ++ programming language. The first part of my project was determination of calibration factor of pressure sensors. Based on that result, I examined the relation between pressure drop, gas flow rate of in paper filter and its diameter.

  6. Blood pressure and anthropometric measurements in healthy ...

    African Journals Online (AJOL)

    Methods. We measured the blood pressures of 650 healthy, randomly ... In addition, blood pressure measurement should be a part of the routine clinical examination of children. ... familial risk factors.2 ... common cause of elevated blood pressure in children.4 They ... sphygmomanometer (Accoson, hospital model BS 274,.

  7. Vapor pressure measured with inflatable plastic bag

    Science.gov (United States)

    1965-01-01

    Deflated plastic bag in a vacuum chamber measures initial low vapor pressures of materials. The bag captures the test sample vapors and visual observation of the vapor-inflated bag under increasing external pressures yields pertinent data.

  8. Posterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Steve J. Hodges

    2009-01-01

    Full Text Available The most common cause of lower urinary tract obstruction in male infants is posterior urethral valves. Although the incidence has remained stable, the neonatal mortality for this disorder has improved due to early diagnosis and intensive neonatal care, thanks in part to the widespread use of prenatal ultrasound evaluations. In fact, the most common reason for the diagnosis of posterior urethral valves presently is the evaluation of infants for prenatal hydronephrosis. Since these children are often diagnosed early, the urethral obstruction can be alleviated rapidly through catheter insertion and eventual surgery, and their metabolic derangements can be normalized without delay, avoiding preventable infant mortality. Of the children that survive, however, early diagnosis has not had much effect on their long-term prognosis, as 30% still develop renal insufficiency before adolescence. A better understanding of the exact cause of the congenital obstruction of the male posterior urethra, prevention of postnatal bladder and renal injury, and the development of safe methods to treat urethral obstruction prenatally (and thereby avoiding the bladder and renal damage due to obstructive uropathy are the goals for the care of children with posterior urethral valves[1].

  9. Urethral Cancer—Patient Version

    Science.gov (United States)

    Urethral cancer is rare and is more common in men than in women. Urethral cancer can metastasize (spread) quickly to tissues around the urethra and has often spread to nearby lymph nodes by the time it is diagnosed. Start here to find information on urethral cancer treatment.

  10. A microwave pressure sounder. [for remote measurement of atmospheric pressure

    Science.gov (United States)

    Peckham, G. E.; Flower, D. A.

    1981-01-01

    A technique for the remote measurement of atmospheric surface pressure will be described. Such measurements could be made from a satellite in polar orbit and would cover many areas for which conventional meteorological data are not available. An active microwave instrument is used to measure the strength of return echoes from the ocean surface at a number of frequencies near the 60 GHz oxygen absorption band. Factors which affect the accuracy with which surface pressure can be deduced from these measurements will be discussed and an instrument designed to test the method by making measurements from an aircraft will be described.

  11. Measurement of intraocular pressure with pressure phosphene tonometry in children.

    Science.gov (United States)

    Fan, Dorothy S P; Chiu, Thomas Y H; Congdon, Nathan; Chan, Jeffrey C W; Cheung, Eva Y Y; Lam, Dennis S C

    2011-01-01

    To study the accuracy and acceptability of intraocular pressure (IOP) measurement by the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer in children. Fifty children (5 to 14 years old) participated in this prospective comparative study. IOP was measured with the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer by three different examiners who were masked to the results. The children were also asked to grade the degree of discomfort from 0 to 5 (0 = no discomfort; 5 = most discomfort). The mean IOPs measured by the Goldmann tonometer, pressure phosphene tonometer, and non-contact tonometer were 15.9 mm Hg (standard deviation [SD]: = 5.5 mm Hg; range: 10 to 36 mm Hg), 16.0 mm Hg (SD: 2.9 mm Hg; range: 12 to 25 mm Hg), and 15.7 mm Hg (SD = 5.1 mm Hg; range: 8 to 32 mm Hg), respectively (P = .722). The mean difference between pressure phosphene tonometer and Goldmann tonometer readings was 2.9 mm Hg and that between non-contact tonometer and Goldmann tonometer readings was 2.1 mm Hg. The 95% confidence interval of the mean difference between pressure phosphene tonometer and Goldmann tonometer readings was -1.07 and 1.19, and that between non-contact tonometer and Goldmann tonometer readings was -1.07 and 0.53. The mean discomfort ratings for the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer were 0.6, 2.0, and 2.3, respectively (P tonometer was less accurate than the non-contact tonometer compared with Goldmann tonometer, it gave a reasonably close estimate and had a high specificity of raised IOP. In addition, measurement by the pressure phosphene tonometer is most acceptable to children. The pressure phosphene tonometer can be considered as an alternative method of IOP measurement in children. Copyright 2011, SLACK Incorporated.

  12. Commentary on differential-pressure measurements at high reference pressures

    International Nuclear Information System (INIS)

    Hasbrouck, R.T.; Noyes, R.P.

    1981-01-01

    Some practical approaches to the difficult problems in calibrating and implementing differential-pressure measurements are discussed. The data presented were gathered several years ago in separate investigations. An attempt is made to compare the results of these investigations to the common mode concept as described by Peter K. Stein in his publication, The Measurement of Differential Quantities - Problems and Approaches. Although one of these investigations involed a 10,000- to 20,000-psi reference-pressure gas measured at an ambient temperature and the other a classic /sup Δ/P flow measurement of cryogenic temperature, the problems encountered were the same

  13. Anaerobes in men with urethritis

    OpenAIRE

    Fontaine, E A; Taylor-Robinson, D; Hanna, N F; Coufalik, E D

    1982-01-01

    Sixty-four men with non-gonococcal urethritis (NGU), seven with gonococcal urethritis (GU), and 30 who had no symptoms or signs of urethritis were studied. Chlamydia trachomatis was isolated from urethral specimens taken from 22% of the men with NGU, and 18% with GU, but not from those who did not have urethritis even though 20 (67%) of them had a history of NGU, GU, or both. The chlamydial isolation rate for men having NGU for the first time was 30%. Ureaplasma urealyticum was isolated from ...

  14. Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure.

    NARCIS (Netherlands)

    Kiers, H.D.; Hofstra, J.M.; Wetzels, J.F.M.

    2008-01-01

    Mean arterial pressure (MAP) is often used as an index of overall blood pressure. In recent years, the use of automated oscillometric blood pressure measurement devices is increasing. These devices directly measure and display MAP; however, MAP is often calculated from systolic blood pressure (SBP)

  15. Pirani pressure sensor with distributed temperature measurement

    NARCIS (Netherlands)

    de Jong, B.R.; Bula, W.P.; Zalewski, D.R.; van Baar, J.J.J.; Wiegerink, Remco J.

    2003-01-01

    Surface micro-machined distributed Pirani pressure gauges, with designed heater-to-heat sink distances (gap-heights) of 0.35 μm and 1.10 μm, are successfully fabricated, modeled and characterized. Measurements and model response correspond within 5% of the measured value in a pressure range of 10 to

  16. Palpatory method of measuring diastolic blood pressure

    Directory of Open Access Journals (Sweden)

    Dinesh Sahu

    2010-01-01

    Conclusion: The palpatory method would be very useful where frequent blood pressure measurement are being done manually like in wards, in busy OPD, patient on treadmill and also whenever stethoscope is not available. The blood pressure can be measured in noisy environment too.

  17. Urethral dysfunction in female mice with estrogen receptor β deficiency.

    Directory of Open Access Journals (Sweden)

    Yung-Hsiang Chen

    Full Text Available Estrogen has various regulatory functions in the growth, development, and differentiation of the female urogenital system. This study investigated the roles of ERβ in stress urinary incontinence (SUI. Wild-type (ERβ(+/+ and knockout (ERβ(-/- female mice were generated (aged 6-8 weeks, n = 6 and urethral function and protein expression were measured. Leak point pressures (LPP and maximum urethral closure pressure (MUCP were assessed in mice under urethane anesthesia. After the measurements, the urethras were removed for proteomic analysis using label-free quantitative proteomics by nano-liquid chromatography-mass spectrometry (LC-MS/MS analysis. The interaction between these proteins was further analysed using MetaCore. Lastly, Western blot was used to confirm the candidate proteins. Compared with the ERβ(+/+ group, the LPP and MUCP values of the ERβ(-/- group were significantly decreased. Additionally, we identified 85 differentially expressed proteins in the urethra of ERβ(-/- female mice; 57 proteins were up-regulated and 28 were down-regulated. The majority of the ERβ knockout-modified proteins were involved in cell-matrix adhesion, metabolism, immune response, signal transduction, nuclear receptor translational regelation, and muscle contraction and development. Western blot confirmed the up-regulation of myosin and collagen in urethra. By contrast, elastin was down-regulated in the ERβ(-/- mice. This study is the first study to estimate protein expression changes in urethras from ERβ(-/- female mice. These changes could be related to the molecular mechanism of ERβ in SUI.

  18. Micro packaged MEMS pressure sensor for intracranial pressure measurement

    International Nuclear Information System (INIS)

    Liu Xiong; Yao Yan; Ma Jiahao; Zhang Zhaohua; Zhang Yanhang; Wang Qian; Ren Tianling

    2015-01-01

    This paper presents a micro packaged MEMS pressure sensor for intracranial pressure measurement which belongs to BioMEMS. It can be used in lumbar puncture surgery to measure intracranial pressure. Miniaturization is key for lumbar puncture surgery because the sensor must be small enough to allow it be placed in the reagent chamber of the lumbar puncture needle. The size of the sensor is decided by the size of the sensor chip and package. Our sensor chip is based on silicon piezoresistive effect and the size is 400 × 400 μm 2 . It is much smaller than the reported polymer intracranial pressure sensors such as liquid crystal polymer sensors. In terms of package, the traditional dual in-line package obviously could not match the size need, the minimal size of recently reported MEMS-based intracranial pressure sensors after packaging is 10 × 10 mm 2 . In this work, we are the first to introduce a quad flat no-lead package as the package form of piezoresistive intracranial pressure sensors, the whole size of the sensor is minimized to only 3 × 3 mm 2 . Considering the liquid measurement environment, the sensor is gummed and waterproof performance is tested; the sensitivity of the sensor is 0.9 × 10 −2 mV/kPa. (paper)

  19. Fast Neutral Pressure Measurements in NSTX

    International Nuclear Information System (INIS)

    R. Raman; H.W. Kugel; T. Provost; R. Gernhardt; T.R. Jarboe; M.G. Bell

    2002-01-01

    Several fast neutral pressure gauges have been installed on NSTX [National Spherical Torus Experiment] to measure the vessel and divertor pressure during inductive and coaxial helicity injected (CHI) plasma operations. Modified, PDX [Poloidal Divertor Experiment]-type Penning gauges have been installed on the upper and lower divertors. Neutral pressure measurements during plasma operations from these and from two shielded fast Micro ion gauges at different toroidal locations on the vessel mid-plane are described. A new unshielded ion gauge, referred to as the In-vessel Neutral Pressure (INP) gauge is under development

  20. Measuring Viscosities of Gases at Atmospheric Pressure

    Science.gov (United States)

    Singh, Jag J.; Mall, Gerald H.; Hoshang, Chegini

    1987-01-01

    Variant of general capillary method for measuring viscosities of unknown gases based on use of thermal mass-flowmeter section for direct measurement of pressure drops. In technique, flowmeter serves dual role, providing data for determining volume flow rates and serving as well-characterized capillary-tube section for measurement of differential pressures across it. New method simple, sensitive, and adaptable for absolute or relative viscosity measurements of low-pressure gases. Suited for very complex hydrocarbon mixtures where limitations of classical theory and compositional errors make theoretical calculations less reliable.

  1. Experimental Pressure Measurements on Hydropower Turbine Runners

    Energy Technology Data Exchange (ETDEWEB)

    Harding, Samuel F.; Richmond, Marshall C.

    2017-04-28

    The range of hydrodynamic operating conditions to which the turbine is exposed results in significant pressure fluctuations on both the pressure and suction sides of the blades. Understanding these dynamic pressures has a range of applications. Structurally, the resulting dynamic loads are significant in understanding the design life and maintenance schedule of the bearing, shafts and runner components. The pulsing pressures have also been seen to have a detrimental effect on the surface condition of the blades. Biologically, the pressure gradients and pressure extremes are the primary driver of barotrauma for fish passing through hydroturbines. Improvements in computational fluid dynamics (CFD) can be used to simulate such unsteady pressures in the regions of concern. High frequency model scale and prototype measurements of pressures at the blade are important in the validation of these models. Experimental characterization of pressure fields over hydroturbine blades has been demonstrated by a number of studies which using multiple pressure transducers to map the pressure contours on the runner blades. These have been performed at both model and prototype scales, often to validate computational models of the pressure and flow fields over the blades. This report provides a review of existing studies in which the blade pressure was measured in situ. The report assesses the technology for both model and prototype scale testing. The details of the primary studies in this field are reported and used to inform the types of hardware required for similar experiments based on the Ice Harbor Dam owned by the US Corps of Engineers on the Snake River, WA, USA. Such a study would be used to validate the CFD performed for the BioPA.

  2. Intelligent pressure measurement in multiple sensor arrays

    International Nuclear Information System (INIS)

    Matthews, C.A.

    1995-01-01

    Pressure data acquisition has typically consisted of a group of sensors scanned by an electronic or mechanical multiplexer. The data accuracy was dependent upon the temperature stability of the sensors. This paper describes a new method of pressure measurement that combines individual temperature compensated pressure sensors, a microprocessor, and an A/D converter in one module. Each sensor has its own temperature characteristics stored in a look-up table to minimize sensor thermal errors. The result is an intelligent pressure module that can output temperature compensated engineering units over an Ethernet interface. Calibration intervals can be dramatically extended depending upon system accuracy requirements and calibration techniques used

  3. Thermogravimetric measurements of liquid vapor pressure

    International Nuclear Information System (INIS)

    Rong Yunhong; Gregson, Christopher M.; Parker, Alan

    2012-01-01

    Highlights: ► Rapid determination of vapor pressure by TGA. ► Demonstration of limitations of currently available approaches in literature. ► New model for vapor pressure assessment of small size samples in TGA. ► New model accounts for vapor diffusion and sample geometry and measures vapor pressure normally within 10%. - Abstract: A method was developed using thermo-gravimetric analysis (TGA) to determine the vapor pressure of volatile liquids. This is achieved by measuring the rate of evaporation (mass loss) of a pure liquid contained within a cylindrical pan. The influence of factors like sample geometry and vapor diffusion on evaporation rate are discussed. The measurement can be performed across a wide range of temperature yielding reasonable results up to 10 kPa. This approach may be useful as a rapid and automatable method for measuring the volatility of flavor and fragrance raw materials.

  4. Transrectal ultrasound in male urethritis.

    OpenAIRE

    Ghaly, A F; Taylor, P M; Goorney, B P; Haye, K R

    1994-01-01

    OBJECTIVE--To assess the prevalence of prostatic abnormalities in men with gonococcal and non-gonococcal urethritis using trans-rectal ultrasonic markers. DESIGN--A case control study of patients attending a department of genitourinary medicine with symptoms of urethritis. SETTING--Department of Genitourinary Medicine and Department of Radiology in Manchester Royal Infirmary. RESULTS--A total of 42 patients were recruited to the study: 26 with urethritis and 16 controls. Of the 26 study patie...

  5. Female urethral carcinoma

    International Nuclear Information System (INIS)

    Saitoh, Masahiko; Kondo, Atsuo; Sakakibara, Toshihumi

    1988-01-01

    Urethral carcinoma in 2 females has been treated with irradiation together with adjunct chemotherapy. In case 1, a 73-year-old female with squamous cell carcinoma was successfully treated with irradiation of 4,000 rad and peplomycin of 60 mg intravenously given. She has been free from the disease for the past 43 months. In case 2, a 61-year-old female with transitional cell carcinoma was initially treated with irradiation of 5,000 rad together with peplomycin 90 mg, which was followed by another 5,000 rad irradiation. The tumor recurred and the patient was operated on for cystourethrectomy and partial resection of the vagina. A further chemotherapy of cisplatin, peplomycin, and mitomycin C was instituted. She died of the tumor recurrence 23 months after the first visit to our clinic. Diagnosis and treatment modalities on the female urethral carcinoma are briefly discussed. (author)

  6. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  7. Pancreas tumor interstitial pressure catheter measurement

    Science.gov (United States)

    Nieskoski, Michael D.; Gunn, Jason; Marra, Kayla; Trembly, B. Stuart; Pogue, Brian W.

    2016-03-01

    This paper highlights the methodology in measuring interstitial pressure in pancreatic adenocarcinoma tumors. A Millar Mikrotip pressure catheter (SPR-671) was used in this study and a system was built to amplify and filter the output signal for data collection. The Millar pressure catheter was calibrated prior to each experiment in a water column at 37°C, range of 0 to 60 inH2O (112 mmHg), resulting in a calibration factor of 33 mV / 1 inH2O. The interstitial pressures measured in two orthotopically grown pancreatic adenocarcinoma tumor were 57 mmHg and 48 mmHg, respectively. Verteporfin uptake into the pancreatic adenocarcinoma tumor was measured using a probe-based experimental dosimeter.

  8. Pressure measurements in magnetic-fusion devices

    International Nuclear Information System (INIS)

    Dylla, H.F.

    1981-11-01

    Accurate pressure measurements are important in magnetic fusion devices for: (1) plasma diagnostic measurements of particle balance and ion temperature; (2) discharge cleaning optimization; (3) vacuum system performance; and (4) tritium accountability. This paper reviews the application, required accuracy, and suitable instrumentation for these measurements. Demonstrated uses of ionization-type and capacitance-diaphragm gauges for various pressure and gas-flow measurements in tokamaks are presented, with specific reference to the effects of magnetic fields on gauge performance and the problems associated with gauge calibration

  9. On output measurements via radiation pressure

    DEFF Research Database (Denmark)

    Leeman, S.; Healey, A.J.; Forsberg, F.

    1990-01-01

    It is shown, by simple physical argument, that measurements of intensity with a radiation pressure balance should not agree with those based on calorimetric techniques. The conclusion is ultimately a consequence of the circumstance that radiation pressure measurements relate to wave momentum, while...... calorimetric methods relate to wave energy. Measurements with some typical ultrasound fields are performed with a novel type of hydrophone, and these allow an estimate to be made of the magnitude of the discrepancy to be expected between the two types of output measurement in a typical case....

  10. Pressure measurements in magnetic-fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Dylla, H.F.

    1981-11-01

    Accurate pressure measurements are important in magnetic fusion devices for: (1) plasma diagnostic measurements of particle balance and ion temperature; (2) discharge cleaning optimization; (3) vacuum system performance; and (4) tritium accountability. This paper reviews the application, required accuracy, and suitable instrumentation for these measurements. Demonstrated uses of ionization-type and capacitance-diaphragm gauges for various pressure and gas-flow measurements in tokamaks are presented, with specific reference to the effects of magnetic fields on gauge performance and the problems associated with gauge calibration.

  11. Fundamentals and clinical perspective of urethral sphincter instability as a contributing factor in patients with lower urinary tract dysfunction--ICI-RS 2014

    NARCIS (Netherlands)

    Kirschner-Hermanns, Ruth; Anding, Ralf; Rosier, Peter; Birder, Lori; Andersson, Karl Erik; Djurhuus, Jens Christian

    AIMS: Urethral pathophysiology is often neglected in discussions of bladder dysfunction. It has been debated whether "urethral sphincter instability," referred to based on observed "urethral pressure variations," is an important aspect of overactive bladder syndrome (OAB). The purpose of this report

  12. [Contemporary possibilities of intraocular pressure measurement].

    Science.gov (United States)

    Hornová, J; Baxant, A

    2013-10-01

    Authors introduced current possibilities of measuring intraocular pressure (IOP). A list of available methods of monitoring IOP is published; contact measurement method IOP directly on the cornea, but also over upper lid, methodology of minimal contact and non-contact measurement. Following contact methods are described; former measurements of IOP by impression Schiotz tonometer and the current methodology applanation. So far as the gold standard measurement Goldmann applanation tonometer (GAT) is considered, another methodology with applanation measurements are compared: Pascal dynamic contoured tonometer (DCT ), BioResonator - resonant applanation tonometer (ART ), digital applanation tonometer Tonopen and last hit: continuous measurement of IOP by Sensimed Triggerfish. Orientation and rapid assessment is palpation pressure control over the lid and measuring by tonometer Diaton. Rebound tonometer (RBT) iCare belongs to measurements with minimal contact, no need anesthetic drops and fluorescein, therefore a self - home version of IOP measurements (Icare ONE) is developed. Non-contact measurement of IOP by different pneumotonometers is popular for screening assessment of IOP. Reichert Ocular Response Analyzer (ORA) is a non-contact applanation IOP measurement and reveals additional properties of the cornea. In the discussion of a range methodology is evaluated, the experience of other authors and their own experience is compared. For monitoring of patients is necessary to select the most suitable methodology, measure repeatedly and accurately to allow long-term monitoring of intraocular pressure.

  13. Urethral anatomy and semen flow during ejaculation

    Science.gov (United States)

    Kelly, Diane

    2016-11-01

    Ejaculation is critical for reproductive success in many animals, but little is known about its hydrodynamics. In mammals, ejaculation pushes semen along the length of the penis through the urethra. Although the urethra also carries urine during micturition, the flow dynamics of micturition and ejaculation differ: semen is more viscous than urine, and the pressure that drives its flow is derived primarily from the rhythmic contractions of muscles at the base of the penis, which produce pulsatile rather than steady flow. In contrast, Johnston et al. (2014) describe a steady flow of semen through the crocodilian urethral groove during ejaculation. Anatomical differences of tissues associated with mammalian and crocodilian urethral structures may underlie these differences in flow behavior.

  14. The impact of tension-free vaginal tape on the urethral closure function

    DEFF Research Database (Denmark)

    Saaby, Marie-Louise; Klarskov, Niels; Lose, Gunnar

    2015-01-01

    AIM: To investigate if the tension-free vaginal tape (TVT) works by increasing the abdominal to urethral pressure impact ratio (APIR). METHODS: Twenty one women with urodynamically proven stress urinary incontinence (SUI) were assessed by ICIQ-SF, pad-weighing test, incontinence diary and Urethral...

  15. Measurement of pressure pulsations in Francis turbines

    Energy Technology Data Exchange (ETDEWEB)

    Kobro, Einar

    2010-11-15

    The work presented in this thesis involves preparation and execution of measurements on Francis runners. The measurements were performed by means of onboard measuring equipment both in model runners and full-scale prototype runners. Also, analysis of the measured data, and the discussion of the results, is presented. The measurements resulted in large data sets. These data sets were used by the author to investigate the dynamic pressure and strain in the runners. The results of the analysis can be used as input in future turbine design. Andritz Hydro AG has used the data for verification of their numerical simulation tools. In connection with the refurbishment of Tokke power plant, two model runners were made available for onboard pressure measurements. To investigate the dynamic pressure in these runners, methods for integration of pressure transducers in the runner blades needed to be developed. After initial difficulties during the preparation, successful measurements were obtained from both model runners. At Tokke power plant, both the original and replacement runners were made accessible for onboard pressure and strain gauge measurements. On the original Kvaerner Brug AS runner, the test was prepared and performed by the author. This test failed, due to water intrusion in the logging chain. The second test was performed on the Andritz Hydro AG replacement runner. This test was prepared and performed by the author in close cooperation with Andritz Hydro AG, and the results were successful. The analysis results from both model and prototype runners show that the wake leaving the guide vanes is the most severe source of dynamic pressure in the runner. The draft tube vortex rope pulsation propagates upstream the runner, but does not appear as a significant frequency in the runner strain measurements. (Author)

  16. Comparison of radiographic and sonographic urethrography for assessing urethral strictures

    International Nuclear Information System (INIS)

    Babnik Peskar, Darja; Visnar Perovic, Alenka

    2004-01-01

    The aim of this study was to compare radiourethrography (RUG) and sonourethrography (SUG) for assessment of urethral strictures and to evaluate whether RUG underestimates stricture length, as has been reported. Fifty-one men with suspected urethral strictures were evaluated by both methods performed consecutively. Stricture lengths and diameters measured by RUG were significantly greater (mean 22%, 30%) than those measured by SUG because of radiographic magnification. Both methods, however, detected a similar percentage lumen reduction and similarly graded stricture severity. Equally significant non-correlation between both methods for length measurements in the bulbar and penile urethra (p 2 =0.33 and 0.34, respectively) supported radiographic magnification. Previous inaccuracies appear to relate to RUG measurements of the central tight stricture (mean 44% of the entire length in our series), not the full stricture length. Use of sonographic contrast medium intra-urethrally improved the definition of long narrow strictures. The SUG gave information about peri-urethral tissues not provided by RUG. Once radiographic magnification was taken into account, there were no major differences in the assessment of urethral strictures by both methods. With correct measurement methods, RUG does not underestimate stricture length. For full assessment, the combination of RUG and SUG, which gives information about peri-urethral disease, is optimal in many patients. (orig.)

  17. Strain measurements during pressurized thermal shock experiment

    International Nuclear Information System (INIS)

    Tarso Vida Gomes, P. de; Julio Ricardo Barreto Cruz; Tanius Rodrigues Mansur; Denis Henrique Bianchi Scaldaferri; Miguel Mattar Neto

    2005-01-01

    For the life extension of nuclear power plants, the residual life of most of their components must be evaluated along all their operating time. Concerning the reactor pressure vessel, the pressurized thermal shock (PTS) is a very important event to be considered. For better understanding the effects of this kind of event, tests are made. The approach described here consisted of building a simplified in-scale physical model of the reactor pressure vessel, submitting it to the actual operating temperature and pressure conditions and provoking a thermal shock by means of cold water flow in its external surface. To conduct such test, the Nuclear Technology Development Center (CDTN) has been conducting several studies related to PTS and has also built a laboratory that has made possible the simulation of the PTS loading conditions. Several cracks were produced in the external surface of the reactor pressure vessel model. Strain gages were fixed by means of electrical discharge welding over the cracks regions in both external and internal surfaces. The temperature was monitored in 10 points across the vessel wall. The internal pressure was manually controlled and monitored using a pressure transducer. Two PTS experiments were conducted and this paper presents the strain measurement procedures applied to the reactor pressure vessel model, during the PTS, using strain gages experimental methodology. (authors)

  18. A gas thermometer for vapor pressure measurements

    Science.gov (United States)

    Rusin, A. D.

    2008-08-01

    The pressure of an inert gas over the range 400 1000 K was measured on a tensimetric unit with a quartz membrane pressure gauge of enhanced sensitivity. It was shown that a reactor with a membrane null gauge could be used as a gas thermometer. The experimental confidence pressure and temperature intervals were 0.07 torr and 0.1 K at a significance level of 0.05. A Pt-Pt/10% Rh thermocouple was calibrated; the results were approximated by a polynomial of degree five. The error in temperature calculations was 0.25 K.

  19. Uncertainties for pressure-time efficiency measurements

    OpenAIRE

    Ramdal, Jørgen; Jonsson, Pontus; Dahlhaug, Ole Gunnar; Nielsen, Torbjørn; Cervantes, Michel

    2010-01-01

     In connection with the pressure-time project at the Norwegian University of Science and Technology and Luleå University of Technology, a number of tests with the pressure-time method have been performed at the Waterpower Laboratory in Trondheim, Norway. The aim is to lower the uncertainty and improve usability of the method. Also a field test at the Anundsjoe power plant in Sweden has been performed. The pressure-time measurement is affected by random uncertainty. To minimize the effect of t...

  20. Calculi in female urethral diverticulum

    DEFF Research Database (Denmark)

    Hansen, B J; Hørby, J; Brynitz, S

    1989-01-01

    A case of two calculi found in the same urethral diverticulum in a 41-year-old woman with recurrent urinary tract infections is reported. The diagnostic procedures are discussed.......A case of two calculi found in the same urethral diverticulum in a 41-year-old woman with recurrent urinary tract infections is reported. The diagnostic procedures are discussed....

  1. Measuring the osmotic pressure of active colloids

    Science.gov (United States)

    Wang, Michael; Soni, Vishal; Magkiriadou, Sofia; Ferrari, Melissa; Youssef, Mina; Driscoll, Michelle; Sacanna, Stefano; Chaikin, Paul; Irvine, William

    We study the behavior of a system of colloidal spinners, consisting of weakly magnetic colloids driven by a rotating magnetic field. First the particles are allowed to sediment to an equilibrium density profile in a gravitational field, from which we measure the equilibrium equation of state. By spinning the particles at various frequencies, we introduce activity into the system through the hydrodynamic interactions between particles. We observe that the activity expands the sedimentation profile to a new steady state, from which we measure the pressure as a function of the density and activity. We compare the effects of activity on the pressure and mean-squared displacement of spinners and tracer particles.

  2. Symptoms of non-gonococcal urethritis in heterosexual men: a case control study.

    Science.gov (United States)

    Iser, P; Read, Tr H; Tabrizi, S; Bradshaw, C; Lee, D; Horvarth, L; Garland, S; Denham, I; Fairley, C K

    2005-04-01

    To determine microbial and behavioural factors contributing to non-gonococcal urethral symptoms in men. Case-control study of heterosexual men with non-gonococcal urethral symptoms (cases) and without urethral symptoms (controls) attending Melbourne Sexual Health Centre, Australia. Sexual behaviour and condom use were measured by questionnaire. First stream urine was tested for potential pathogens: Chlamydia trachomatis (ligase chain reaction), Mycoplasma genitalium (polymerase chain reaction, PCR), Ureaplasma urealyticum (culture and PCR), and Streptococcus spp, Gardnerella vaginalis, and Haemophilus species (culture). Urethral smears from cases were examined for polymorphonuclear leucocytes. 80 cases and 79 controls were recruited over 4 months in 2002-3. 49 cases (61%) had urethritis by microscopic criteria, 17 (21%) had Chlamydia trachomatis (adjusted odds ratio (OR) 27 (95% confidence interval (CI): 3.4 to 222)), five (6%) had Mycoplasma genitalium (OR 6.1 (95% CI: 0.6 to 61)), and 11 (14%) had Gardnerella vaginalis (OR 9.0 (95% CI: 1.6 to 52)). Other organisms were not significantly associated with urethral symptoms. The presence of urethritis on urethral smear did not predict the presence of Chlamydia trachomatis (OR 1.7 (95% CI: 0.5 to 5.4)). Urethral symptoms were significantly associated with unprotected vaginal sex with more than one casual partner (OR 9.3 (95% CI: 1.3 to 65)) and unprotected anal sex with a regular partner in the past month (OR 3.5 (95% CI: 1.0 to 13)). Gardnerella vaginalis and unprotected anal sex may cause symptoms of non-gonococcal urethritis. Microscopy of the urethral smear to diagnose urethritis in this population does not help to identify which men with urethral symptoms require treatment for chlamydia.

  3. Side abutment pressure distribution by field measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lian-guo Wang; Yang Song; Xing-hua He; Jian Zhang [State Key Laboratory for Geomechanics and Deep Underground Engineering, Xuzhou (China)

    2008-12-15

    Given the 7123 working face in the Qidong Coal Mine of the Wanbei Mining Group, nine dynamic roof monitors were installed in the crossheading to measure the amount and velocity of roof convergence in different positions and at different times and three steel bored stress sensors were installed in the return airway to measure rock stress at depth. On the basis of this arrangement, the rule of change of the distribution of the side abutment pressure with the advance of the working face and movement of overlying strata was studied. The rule of change and the stability of rock stress at depth were measured. Secondly, the affected area and stability time of the side abutment pressure were also studied. The results show that: 1) During working, the face advanced distance was from 157 m to 99 m, the process was not effected by mining induced pressure. When the distance was 82 m, the position of peak stress was 5 m away from the coal wall. When the distance was 37 m, the position of peak stress away from the coal wall was about 15 m to 20 m and finally reached a steady state; 2) the time and the range of the peak of side rock pressure obtained from stress sensors were consistent with the results from the dynamic roof monitors; 3) the position of the peak pressure was 25 m away from the coal wall. 14 refs., 6 figs.

  4. Eccentric pressurized tube for measuring creep rupture

    International Nuclear Information System (INIS)

    Schwab, P.R.

    1981-01-01

    Creep rupture is a long term failure mode in structural materials that occurs at high temperatures and moderate stress levels. The deterioration of the material preceding rupture, termed creep damage, manifests itself in the formation of small cavities on grain boundaries. To measure creep damage, sometimes uniaxial tests are performed, sometimes density measurements are made, and sometimes the grain boundary cavities are measured by microscopy techniques. The purpose of the present research is to explore a new method of measuring creep rupture, which involves measuring the curvature of eccentric pressurized tubes. Theoretical investigations as well as the design, construction, and operation of an experimental apparatus are included in this research

  5. High Temperature Dynamic Pressure Measurements Using Silicon Carbide Pressure Sensors

    Science.gov (United States)

    Okojie, Robert S.; Meredith, Roger D.; Chang, Clarence T.; Savrun, Ender

    2014-01-01

    Un-cooled, MEMS-based silicon carbide (SiC) static pressure sensors were used for the first time to measure pressure perturbations at temperatures as high as 600 C during laboratory characterization, and subsequently evaluated in a combustor rig operated under various engine conditions to extract the frequencies that are associated with thermoacoustic instabilities. One SiC sensor was placed directly in the flow stream of the combustor rig while a benchmark commercial water-cooled piezoceramic dynamic pressure transducer was co-located axially but kept some distance away from the hot flow stream. In the combustor rig test, the SiC sensor detected thermoacoustic instabilities across a range of engine operating conditions, amplitude magnitude as low as 0.5 psi at 585 C, in good agreement with the benchmark piezoceramic sensor. The SiC sensor experienced low signal to noise ratio at higher temperature, primarily due to the fact that it was a static sensor with low sensitivity.

  6. Equipment for liquid metal pressure measurement

    International Nuclear Information System (INIS)

    Jung, J.

    1977-01-01

    Equipment is proposed for measuring liquid metal pressure in piping or a tank. An auxiliary piping is connected to the piping or tank at the measuring point. The auxiliary piping transports liquid metal to a container by means of an electromagnetic pump. The piping also houses an electromagnetic flow ratemeter connected to an electric comparator. The comparator and the electromagnetic pump are connected to the pump output generator. (Z.M.)

  7. Correlação entre a pressão de perda à manobra de Valsalva e a pressão máxima de fechamento uretral com a história clínica em mulheres com incontinência urinária de esforço Correlation of Valsalva leak point pressure and maximal urethral closure pressure with clinical history in women with stress urinary incontinence

    Directory of Open Access Journals (Sweden)

    Paulo Cezar Feldner Jr

    2002-08-01

    incontinence. Valsalva leak point pressure (VLPP was measured with a vesical volume of 200 mL. Urethral profile was determined using a flow catheter number 8 with measurement of maximum urethral closure pressure (MUCP. Data were compared by chi², ANOVA and Tukey tests. Results: mean age was 51.2 years (19-82, 76 women (47.2% were in menacme and 85 (52.8% in postmenopausal status. Mean parity was 3.9 (0-18. The exact test for trend demonstrated a statistically significant (p<0.0001 correlation between the number of patients with VLPP of 60 cmH2O or less and clinical complaints. The group with severe leakage had mean VLPP of 69.1 cmH2O. The group with moderated leakage had mean VLPP of 84.6 cmH2O and the group with mild leakage had mean VLPP of 90.6 cmH2O. Conclusions: VLPP correlated with the subjective degree of stress urinary incontinence. Higher grades of stress urinary incontinence had a higher likelyhood of a low VLPP. MUCP did not correlate with clinical complaints.

  8. Sacral neuromodulation effects on periurethral sensation and urethral sphincter activity.

    Science.gov (United States)

    Gleason, Jonathan L; Kenton, Kimberly; Greer, W Jerod; Ramm, Olga; Szychowski, Jeff M; Wilson, Tracey; Richter, Holly E

    2013-06-01

    To characterize the effect of sacral neuromodulation (SNM) on urethral neuromuscular function. Following IRB approval, women with refractory overactive bladder (OAB) underwent standardized urethral testing prior to and after Stage 1 SNM implantation. Periurethral sensation was measured using current perception thresholds (CPT). Striated urethral sphincter activity was quantified using concentric needle electromyography (CNE) and Multi-Motor Unit Action Potential (MUP) analysis software. Nonparametric analyses were used to characterize pre/post changes with intervention. Baseline CPT and CNE findings were compared between SNM responders and non-responders. Twenty-seven women were enrolled in this pilot study with a mean age of 61 ± 13 years. Twenty of 26 women (76.9%) responded to SNM and went to Stage 2 permanent implantation. Four (14.8%) withdrew after Stage 1 implantation; three of the four withdrawals had not had therapeutic responses to SNM. CPT and CNE parameters did not significantly differ from baseline 2 weeks after SNM. Pre-SNM urethral sensation was not significantly different between responders and non-responders. However, responders had larger amplitude, longer duration and more turns and phases at baseline approaching significance, reflecting more successful urethral reinnervation, than non-responders. SNM does not alter urethral neuromuscular function 2 weeks post Stage 1 implantation. Copyright © 2012 Wiley Periodicals, Inc.

  9. Basic principles for measurement of intramuscular pressure

    Science.gov (United States)

    Hargens, A. R.; Ballard, R. E.

    1995-01-01

    We review historical and methodological approaches to measurements of intramuscular pressure (IMP) in humans. These techniques provide valuable measures of muscle tone and activity as well as diagnostic criteria for evaluation of exertional compartment syndrome. Although the wick and catheter techniques provide accurate measurements of IMP at rest, their value for exercise studies and diagnosis of exertional compartment syndrome is limited because of low frequency response and hydrostatic (static and inertial) pressure artifacts. Presently, most information on diagnosis of exertional compartment syndromes during dynamic exercise is available using the Myopress catheter. However, future research and clinical diagnosis using IMP can be optimized by the use of a miniature transducer-tipped catheter such as the Millar Mikro-tip.

  10. Posterior colporrhaphy does not affect the urethral closure mechanism

    DEFF Research Database (Denmark)

    Khayyami, Yasmine; Lose, Gunnar; Klarskov, Niels

    2018-01-01

    prolapse ≥stage II were examined before and after posterior colporrhaphy. We performed prolapse staging according to the Pelvic Organ Prolapse Quantification system, UPR measurements at rest, during squeezing and straining, and standardized stress tests with 300 ml saline. The women filled out...... International Consultation on Incontinence-Urinary incontinence (ICIQ-UI) short forms. The sample size was 18, with a power of 99.9% and a level of significance of 5%. Parameters were compared using paired t tests or Fisher's exact test, where appropriate; p values ... significant. RESULTS: Eighteen women with posterior vaginal wall prolapse ≥stage II were recruited. One woman did not undergo surgery. There were no changes in urethral pressure at rest (p = 0.4), during squeezing (p = 0.2) or straining (p = 0.2), before and after surgery. The results of the stress tests...

  11. Measurements of Pressure of Extracorporeal Shock Wave Lithotripter Using Pressure-Sensitive Papers

    Science.gov (United States)

    Inose, Naoto; Ide, Masao

    1993-05-01

    This paper describes measurements of pressures at the focal region of the extracorporeal shock wave lithotripter (ESWL) using pressure-sensitive papers. At the focal region of ESWL, ordinary hydrophones are quickly damaged, because of very high pressures. Recently, measurements of pressure at the focal region of ESWL using pressure-sensitive paper have been advised. Therefore, we have studied the effectiveness of pressure-sensitive papers in the measurement of high acoustic pressures at the focal region of ESWL.

  12. Signal quality measures for unsupervised blood pressure measurement

    International Nuclear Information System (INIS)

    Abdul Sukor, J; Redmond, S J; Lovell, N H; Chan, G S H

    2012-01-01

    Accurate systolic and diastolic pressure estimation, using automated blood pressure measurement, is difficult to achieve when the transduced signals are contaminated with noise or interference, such as movement artifact. This study presents an algorithm for automated signal quality assessment in blood pressure measurement by determining the feasibility of accurately detecting systolic and diastolic pressures when corrupted with various levels of movement artifact. The performance of the proposed algorithm is compared to a manually annotated reference scoring (RS). Based on visual representations and audible playback of Korotkoff sounds, the creation of the RS involved two experts identifying sections of the recorded sounds and annotating sections of noise contamination. The experts determined the systolic and diastolic pressure in 100 recorded Korotkoff sound recordings, using a simultaneous electrocardiograph as a reference signal. The recorded Korotkoff sounds were acquired from 25 healthy subjects (16 men and 9 women) with a total of four measurements per subject. Two of these measurements contained purposely induced noise artifact caused by subject movement. Morphological changes in the cuff pressure signal and the width of the Korotkoff pulse were extracted features which were believed to be correlated with the noise presence in the recorded Korotkoff sounds. Verification of reliable Korotkoff pulses was also performed using extracted features from the oscillometric waveform as recorded from the inflatable cuff. The time between an identified noise section and a verified Korotkoff pulse was the key feature used to determine the validity of possible systolic and diastolic pressures in noise contaminated Korotkoff sounds. The performance of the algorithm was assessed based on the ability to: verify if a signal was contaminated with any noise; the accuracy, sensitivity and specificity of this noise classification, and the systolic and diastolic pressure

  13. Automatic Blood Pressure Measurements During Exercise

    Science.gov (United States)

    Weaver, Charles S.

    1985-01-01

    Microprocessor circuits and a computer algorithm for automatically measuring blood pressure during ambulatory monitoring and exercise stress testing have been under development at SRI International. A system that records ECG, Korotkov sound, and arm cuff pressure for off-line calculation of blood pressure has been delivered to NASA, and an LSLE physiological monitoring system that performs the algorithm calculations in real-time is being constructed. The algorithm measures the time between the R-wave peaks and the corresponding Korotkov sound on-set (RK-interval). Since the curve of RK-interval versus cuff pressure during deflation is predictable and slowly varying, windows can be set around the curve to eliminate false Korotkov sound detections that result from noise. The slope of this curve, which will generally decrease during exercise, is the inverse of the systolic slope of the brachial artery pulse. In measurements taken during treadmill stress testing, the changes in slopes of subjects with coronary artery disease were markedly different from the changes in slopes of healthy subjects. Measurements of slope and O2 consumption were also made before and after ten days of bed rest during NASA/Ames Research Center bed rest studies. Typically, the maximum rate of O2 consumption during the post-bed rest test is less than the maximum rate during the pre-bed rest test. The post-bed rest slope changes differ from the pre-bed rest slope changes, and the differences are highly correlated with the drop in the maximum rate of O2 consumption. We speculate that the differences between pre- and post-bed rest slopes are due to a drop in heart contractility.

  14. Unusual Giant Prostatic Urethral Calculus

    African Journals Online (AJOL)

    2010-06-29

    Jun 29, 2010 ... Jolly type a) De novo urethral stones are generally composed ... Prepare the title page, covering letter, acknowledgement etc. using a word processor program. ... The main text of the article, beginning with the Abstract to ...

  15. Neisseria gonorrhoeae DNA bacterial load in men with symptomatic and asymptomatic gonococcal urethritis.

    Science.gov (United States)

    Priest, David; Ong, Jason J; Chow, Eric P F; Tabrizi, Sepehr; Phillips, Sam; Bissessor, Melanie; Fairley, Christopher K; Bradshaw, Catriona S; Read, Tim R H; Garland, Suzanne; Chen, Marcus

    2017-11-01

    Previous studies have quantified bacterial loads of Neisseria gonorrhoeae in the pharynx and rectum of men but not the urethra. We quantified the bacterial load of N. gonorrhoeae in men with symptomatic and asymptomatic urethral gonorrhoea infections. Consecutive men diagnosed with urethral gonorrhoea by Aptima Combo 2 testing of urine at the Melbourne Sexual Health Centre between March and July 2016 were eligible for the study: symptomatic men with purulent urethral discharge and asymptomatic men with no urethral symptoms. The gonococcal bacterial load in both groups was measured by urethral swab using a standardised collection method and real-time quantitative PCR targeting the opa gene. Twenty men were recruited into the study: 16 had purulent urethral discharge and 4 had asymptomatic urethral gonorrhoea. The median gonococcal bacterial load was significantly higher among symptomatic men (3.7×10 6 copies per swab, IQR 2.5×10 6 -4.7×10 6 ) compared with asymptomatic men (2.0×10 5 copies per swab, IQR 2.7×10 4 -4.5×10 5 ) (p=0.002). Gonococcal loads in men with urethral discharge were higher than loads seen with asymptomatic urethral gonorrhoea and loads seen in asymptomatic pharyngeal and rectal gonorrhoea infections in previous studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Advances in urethral stricture management

    Science.gov (United States)

    Gallegos, Maxx A.; Santucci, Richard A.

    2016-01-01

    Urethral stricture/stenosis is a narrowing of the urethral lumen. These conditions greatly impact the health and quality of life of patients. Management of urethral strictures/stenosis is complex and requires careful evaluation. The treatment options for urethral stricture vary in their success rates. Urethral dilation and internal urethrotomy are the most commonly performed procedures but carry the lowest chance for long-term success (0–9%). Urethroplasty has a much higher chance of success (85–90%) and is considered the gold-standard treatment. The most common urethroplasty techniques are excision and primary anastomosis and graft onlay urethroplasty. Anastomotic urethroplasty and graft urethroplasty have similar long-term success rates, although long-term data have yet to confirm equal efficacy. Anastomotic urethroplasty may have higher rates of sexual dysfunction. Posterior urethral stenosis is typically caused by previous urologic surgery. It is treated endoscopically with radial incisions. The use of mitomycin C may decrease recurrence. An exciting area of research is tissue engineering and scar modulation to augment stricture treatment. These include the use of acellular matrices or tissue-engineered buccal mucosa to produce grafting material for urethroplasty. Other experimental strategies aim to prevent scar formation altogether. PMID:28105329

  17. Urethral sensation following reconstructive pelvic surgery.

    Science.gov (United States)

    Abernethy, M G; Davis, C; Lowenstein, L; Mueller, E R; Brubaker, L; Kenton, K

    2014-11-01

    Most urethral neuromuscular function data focus on efferent rather than afferent innervation. We aimed to determine if changes exist in urethral afferent nerve function before and after reconstructive pelvic surgery (RPS). Secondarily, we compared afferent urethral innervation in women with and without stress urinary incontinence undergoing RPS. Participants underwent current perception threshold (CPT) and urethral anal reflex (UAR) testing prior to surgery and again post-operatively. Wilcoxon signed ranked test and Spearman's correlations were used and all tests were two-sided. p = 0.05 was considered to indicate statistical significance. Urethral CPT thresholds increased significantly after RPS, consistent with decreased urethral afferent function. Pre-operative urethral CPT thresholds at 5 and 250 Hz were lower in SUI women (10 [IQR 5-29], 40 [32-750]) compared with continent women (63 [14-99], 73 [51-109]; p = 0.45, p = 0.020), signifying increased urethral sensation or easier activation of urethral afferents in SUI women. Reconstructive pelvic surgery is associated with a short-term deleterious impact on urethral afferent function, as demonstrated by the higher levels of stimuli required to activate urethral afferent nerves (decreased urethral sensation) immediately after RPS. Women with SUI required lower levels of stimuli to activate urethral afferent nerves prior to RPS, although UAR latencies were similar regardless of concomitant SUI.

  18. Hybrid Optical Unobtrusive Blood Pressure Measurements

    Directory of Open Access Journals (Sweden)

    Guangfei Zhang

    2017-07-01

    Full Text Available Blood pressure (BP is critical in diagnosing certain cardiovascular diseases such as hypertension. Some previous studies have proved that BP can be estimated by pulse transit time (PTT calculated by a pair of photoplethysmography (PPG signals at two body sites. Currently, contact PPG (cPPG and imaging PPG (iPPG are two feasible ways to obtain PPG signals. In this study, we proposed a hybrid system (called the ICPPG system employing both methods that can be implemented on a wearable device, facilitating the measurement of BP in an inconspicuous way. The feasibility of the ICPPG system was validated on a dataset with 29 subjects. It has been proved that the ICPPG system is able to estimate PTT values. Moreover, the PTT measured by the new system shows a correlation on average with BP variations for most subjects, which could facilitate a new generation of BP measurement using wearable and mobile devices.

  19. Intraocular pressure measurements after conductive keratoplasty.

    Science.gov (United States)

    Kymionis, George D; Naoumidi, Tatiana L; Aslanides, Ioannis M; Kumar, Vinod; Astyrakakis, Nikolaos I; Tsilimbaris, Miltiadis; Pallikaris, Ioannis G

    2005-01-01

    To determine the possible impact of conductive keratoplasty (CK) on intraocular pressure (IOP) measurements. A prospective, single-center, noncomparative interventional case series was performed. Baseline and postoperative IOPs were measured by Goldmann applanation tonometry in 32 eyes of 18 patients who underwent CK for hyperopia correction. Mean follow-up was 11.9 months (range: 8 to 18 months). After CK, a statistically significant decrease in the measured IOP was observed (before CK: 14.22+/-1.64 vs after CK: 12.66+/-2.21, P<.001). The change in IOP readings postoperatively was not correlated with age, sex, keratometric readings, or attempted correction. Despite the limitations due to the small number of patients enrolled in this study, the applanation tonometer appears to underestimate the true IOP after CK.

  20. Pressure measurement using thermal properties of materials

    International Nuclear Information System (INIS)

    Cruz Pessoa, Jose Dalton; Calbo, Adonai Gimenes

    2004-01-01

    This work presents a design and two methods, one isothermal and one isovolumetric, for pressure measurements based on the compressibility coefficient (κ) and thermal expansibility (α) of the fluid under test. The setup and relevant construction details are described. To demonstrate the applicability of the isovolumetric measurement method, the setup was calibrated with respect to a Bourdon-type manometer; the other isothermic method was analyzed to determine construction details that could realize resolution requirements. The authors determined the effect of ambient temperature on device operation and the time response of the isovolumetric method. The device can be used to estimate the compressibility of a fluid and, in addition, could become an alternative for direct plant cell turgor measurement

  1. Polynomial analysis of ambulatory blood pressure measurements

    NARCIS (Netherlands)

    Zwinderman, A. H.; Cleophas, T. A.; Cleophas, T. J.; van der Wall, E. E.

    2001-01-01

    In normotensive subjects blood pressures follow a circadian rhythm. A circadian rhythm in hypertensive patients is less well established, and may be clinically important, particularly with rigorous treatments of daytime blood pressures. Polynomial analysis of ambulatory blood pressure monitoring

  2. Urethral Foreign Body Management: A Case Report

    OpenAIRE

    Chang, Andy Y.; Koh, Chester J.; Stein, John P.

    2004-01-01

    The management of urethral foreign bodies may require the use of various surgical techniques in a urologist's armamentarium. We report a unique case of a urethral foreign body requiring percutaneous and endoscopic techniques for removal.

  3. Partial pressure measurements with an active spectrometer

    International Nuclear Information System (INIS)

    Brooks, N.H.; Jensen, T.H.; Colchin, R.J.; Maingi, R.; Wade, M.R.; Finkenthal, D.F.; Naumenko, N.; Tugarinov, S.

    1998-07-01

    Partial pressure neutral ga measurements have been made using a commercial Penning gauge in conjunction with an active spectrometer. In prior work utilizing bandpass filters and conventional spectrometers, trace concentrations of the hydrogen isotopes H, D, T and of the noble gases He, Ne and Ar were determined from characteristic spectral lines in the light emitted by the neutral species of these elements. For all the elements mentioned, the sensitivity was limited by spectral contamination from a pervasive background of molecular hydrogen radiation. The active spectrometer overcomes this limitations by means of a digital lock-in method and correlation with reference spectra. Preliminary measurements of an admixture containing a trace amount of neon in deuterium show better than a factor of 20 improvement in sensitivity over conventional techniques. This can be further improved by correlating the relative intensities of multiple lines to sets of reference spectra

  4. Female urethral diverticulum containing large calculi

    Directory of Open Access Journals (Sweden)

    Shoichi Kimura

    2018-05-01

    Full Text Available Urinary stones in female urethral diverticulum are rarely seen. We report a 79-year-old woman who presented with irritative lower urinary tract symptoms and vaginal cystocele with incontinence. The urethral stones in the diverticulum were successfully extracted through the trans-urethral route and anterior tension-free vaginal mesh was applied one month later. The patient has been well, with no lower urinary symptoms or incontinence for 4 months. Keywords: Female, Urethral diverticulum, Incontinence, Calculus

  5. On-line pressure measurement using scanning systems

    International Nuclear Information System (INIS)

    Morss, A.G.; Watson, A.P.

    1978-08-01

    Data collection methods can be improved significantly by using pressure scanning systems in conjunction with transducers for the measurement of pressure distribution in fluid flow rigs. However, the response of pressure transducers to the slight random pressure fluctuations that occur in practice can cause some measurement problems, especially for accurate work. The nature of these pressure fluctuations is examined and suitable analysis techniques are recommended. Results obtained using these techniques are presented. It is concluded that by using the correct techniques pressure transducer systems can be used to measure pressure distributions accurately and are sufficiently sensitive to measure very small systematic effects with great precision. (author)

  6. Urethral Cancer—Health Professional Version

    Science.gov (United States)

    Urethral cancer is a rare cancer. There are three types of urethral cancer. Squamous cell carcinoma is the most common type. Transitional cell carcinoma of the urethra, and adenocarcinoma in the glands around the urethra are less common. Find evidence-based information on urethral cancer treatment.

  7. [Three theses on urethral disease].

    Science.gov (United States)

    Chesa-Ponce, N

    2012-01-01

    To inform about three doctorate theses on urethral stenosis, presented in the University of Paris and Montpellier by Spanish authors. Of the Canary Island students who studied medicine in France during the xix century and beginning of the xx century, three stand out for having chosen the same subject for presentation of their doctorate thesis. We briefly analyze their biographies, placing special emphasis on the content of their doctorate thesis. Urethral stenosis was a very mentioned disease during the period studied due to its high incidence. We distinguish the therapeutic changes contributed in the three theses studied. Copyright © 2012 AEU. Published by Elsevier Espana. All rights reserved.

  8. Development and optimization of a device for diferencial pressure measurement

    International Nuclear Information System (INIS)

    Santarine, G.A.

    1980-01-01

    The measurements of reduced values of diferencial pressure, are studied. Several situations are described where the diferencial pressure accurate measurement is necessary in routine works in the Thermohydraulic Laboratory, as well as, the major pressure measurement devices and their respective range are studied. The development of a device for diferencial pressure measurement followed by the design development of the calibration bench covering the foreseen range, start up tests realization, optimization, calibration, performance analysis and conclusions, is showed. (Author) [pt

  9. Biodegradable urethral stent in the treatment of post-traumatic urethral strictures in a war wound rabbit urethral model

    International Nuclear Information System (INIS)

    Fu Weijun; Zhang Binghong; Gao Jiangping; Hong Baofa; Zhang Lei; Yang Yong; Meng Bo; Zhu Ning; Cui Fuzhai

    2007-01-01

    To prevent terrorism during anti-terror war, we developed a reproducible animal model for the induction of a urethral stricture in a war wound rabbit, and to evaluate the feasibility and effect of using a biodegradable urethral stent in the prophylaxis and treatment of urethral strictures in a war wound (or traumatic) rabbit urethral model. The urethral stricture rabbit model was successfully performed by a self-control explosion destructor. New biodegradable urethral stents were placed in the urethras of 20 war wound (traumatic) rabbits, but no stent was used in the 8 rabbits which formed the control group. Follow-up investigation included assessment of procedure success, stent changes, urethrascopy and retrograde urethrography, and histological findings were obtained after sacrifice at 4, 6, 8 and 12 weeks after stent placement. The urethral stricture model owing to a war wound (trauma) was tested by tissue reactions and urethroscopy. The length of the urethral strictures was 5-10 mm; the coarctatetion of the urethral lumen was more than 50%. Biodegradable stent placement was technically successful in 20 rabbits. Urethral specimens obtained from the 4 week stent placement group showed diminished inflammatory cell infiltration and decreased thickness of the papillary projections of the epithelium. There was a strong tendency towards regression of the papillary projections and regeneration of urethral mucosa epithelium in the 8 week group. In particular, the injured urethra has recovered completely in the biodegradable stent groups compared with the control group at 12 weeks. The biodegradable urethral stent seems feasible for treating and preventing urethral strictures owing to a war wound (or traumatic) urethra. There are distinct advantages in terms of safe, effective and less-invasive treatment for the reconstruction of post-traumatic urethral strictures

  10. Biodegradable urethral stent in the treatment of post-traumatic urethral strictures in a war wound rabbit urethral model

    Energy Technology Data Exchange (ETDEWEB)

    Fu Weijun [Department of Urology, Chinese People' s Liberation Army General Hospital, Military Postgraduate Medical College, No.28 Fuxing Road, Hai dian District, Beijing 100853 (China); Zhang Binghong [Department of Urology, Chinese People' s Liberation Army General Hospital, Military Postgraduate Medical College, No.28 Fuxing Road, Hai dian District, Beijing 100853 (China); Gao Jiangping [Department of Urology, Chinese People' s Liberation Army General Hospital, Military Postgraduate Medical College, No.28 Fuxing Road, Hai dian District, Beijing 100853 (China); Hong Baofa [Department of Urology, Chinese People' s Liberation Army General Hospital, Military Postgraduate Medical College, No.28 Fuxing Road, Hai dian District, Beijing 100853 (China); Zhang Lei [Department of Urology, Chinese People' s Liberation Army General Hospital, Military Postgraduate Medical College, No.28 Fuxing Road, Hai dian District, Beijing 100853 (China); Yang Yong [Department of Urology, Chinese People' s Liberation Army General Hospital, Military Postgraduate Medical College, No.28 Fuxing Road, Hai dian District, Beijing 100853 (China); Meng Bo [Biomaterials Lab, School of Materials Science and Engineering, Tsinghua University, Beijing (China); Zhu Ning [Biomaterials Lab, School of Materials Science and Engineering, Tsinghua University, Beijing (China); Cui Fuzhai [Biomaterials Lab, School of Materials Science and Engineering, Tsinghua University, Beijing (China)

    2007-12-15

    To prevent terrorism during anti-terror war, we developed a reproducible animal model for the induction of a urethral stricture in a war wound rabbit, and to evaluate the feasibility and effect of using a biodegradable urethral stent in the prophylaxis and treatment of urethral strictures in a war wound (or traumatic) rabbit urethral model. The urethral stricture rabbit model was successfully performed by a self-control explosion destructor. New biodegradable urethral stents were placed in the urethras of 20 war wound (traumatic) rabbits, but no stent was used in the 8 rabbits which formed the control group. Follow-up investigation included assessment of procedure success, stent changes, urethrascopy and retrograde urethrography, and histological findings were obtained after sacrifice at 4, 6, 8 and 12 weeks after stent placement. The urethral stricture model owing to a war wound (trauma) was tested by tissue reactions and urethroscopy. The length of the urethral strictures was 5-10 mm; the coarctatetion of the urethral lumen was more than 50%. Biodegradable stent placement was technically successful in 20 rabbits. Urethral specimens obtained from the 4 week stent placement group showed diminished inflammatory cell infiltration and decreased thickness of the papillary projections of the epithelium. There was a strong tendency towards regression of the papillary projections and regeneration of urethral mucosa epithelium in the 8 week group. In particular, the injured urethra has recovered completely in the biodegradable stent groups compared with the control group at 12 weeks. The biodegradable urethral stent seems feasible for treating and preventing urethral strictures owing to a war wound (or traumatic) urethra. There are distinct advantages in terms of safe, effective and less-invasive treatment for the reconstruction of post-traumatic urethral strictures.

  11. Current management of urethral stricture disease

    Science.gov (United States)

    Smith, Thomas G.

    2016-01-01

    Introduction: Broadly defined, urethral strictures are narrowing of the urethral lumen that is surrounded by corpus spongiosum, i.e., urethral meatus through the bulbar urethra. Urethral stenosis is narrowing of the posterior urethra, i.e., membranous urethra through bladder neck/prostate junction, which is not enveloped by corpus spongiosum. The disease has significant quality of life ramifications because many times younger patients are affected by this compared to many other urological diseases. Methods: A review of the scientific literature concerning urethral stricture, stenosis, treatment, and outcomes was performed using Medline and PubMed (U.S. National Library of Medicine and the National Institutes of Health). Abstracts from scientific meetings were included in this review. Results: There is level 3 evidence regarding the etiology and epidemiology of urethral strictures, stenoses, and pelvic fracture urethral injuries. Outcomes data from literature regarding intervention for urethral stricture are largely limited to level 3 evidence and expert opinion. There is a single level 1 study comparing urethral dilation and direct vision internal urethrotomy. Urethroplasty outcomes data are limited to level 3 case series. Conclusions: Progress is being made toward consistent terminology, and nomenclature which will, in turn, help to standardize treatment within the field of urology. Treatment for urethral stricture and stenosis remains inconsistent between reconstructive and nonreconstructive urologists due to varying treatment algorithms and approaches to disease management. Tissue engineering appears to be future for reconstructive urethral surgery with reports demonstrating feasibility in the use of different tissue substitutes and grafts. PMID:26941491

  12. A brief review on anterior urethral strictures

    Directory of Open Access Journals (Sweden)

    Li Cheng

    2018-04-01

    Full Text Available The treatment of urethral strictures remains a challenging field in urology even though there are a variety of procedures to treat it at present, as no one approach is superior over another. This paper reviewed the surgical options for the management of different sites and types of anterior urethral stricture, providing a brief discussion of the controversies regarding this issue and suggesting possible future advancements. Among the existing procedures, simple dilation and direct vision internal urethrotomy are more commonly used for short urethral strictures ( <1 cm, soft and no previous intervention. Currently, urethroplasty using buccal mucosa or penile skin is the most widely adopted clinical techniques and have proved successful. Nonetheless, complications such as donor site morbidity remain problem. Tissue engineering techniques are considered as a promising solution for urethral reconstruction, but require further investigation, as does stem cell therapy. Keywords: Anterior urethral strictures, Urethral reconstruction, Tissue engineering, Urethral strictures

  13. Organic Electroluminescent Sensor for Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Tomohide Niimi

    2012-10-01

    Full Text Available We have proposed a novel concept of a pressure sensor called electroluminescent pressure sensor (ELPS based on oxygen quenching of electroluminescence. The sensor was fabricated as an organic light-emitting device (OLED with phosphorescent dyes whose phosphorescence can be quenched by oxygenmolecules, and with a polymer electrode which permeates oxygen molecules. The sensor was a single-layer OLED with Platinum (II octaethylporphine (PtOEP doped into poly(vinylcarbazole (PVK as an oxygen sensitive emissive layer and poly(3,4-ethylenedioxythiophene mixed with poly(styrenesulfonate (PEDOT:PSS as an oxygen permeating polymer anode. The pressure sensitivity of the fabricated ELPS sample was equivalent to that of the sensor excited by an illumination light source. Moreover, the pressure sensitivity of the sensor is equivalent to that of conventional pressure-sensitive paint (PSP, which is an optical pressure sensor based on photoluminescence.

  14. Long-term urethral catheterisation.

    Science.gov (United States)

    Turner, Bruce; Dickens, Nicola

    This article discusses long-term urethral catheterisation, focusing on the relevant anatomy and physiology, indications for the procedure, catheter selection and catheter care. It is important that nurses have a good working knowledge of long-term catheterisation as the need for this intervention will increase with the rise in chronic health conditions and the ageing population.

  15. Anastomotic Urethroplasty for an Obstructing Calculus Within a Bulbar Urethral Diverticulum and Urethral Stricture

    Directory of Open Access Journals (Sweden)

    Pooya Banapour

    2017-01-01

    Full Text Available A 61-year-old male with prior history of endoscopic urethral calculus removal presented to the emergency room with urinary retention and a palpable perineal mass. A CT showed a large calcification within the bulbar urethra. After multiple unsuccessful attempts at foley catheter insertion, the urology service was consulted. The patient was taken to the operating room where an obstructing urethral calculus with associated urethral stricture was visualized on cystoscopy. We present an exceedingly rare case of recurrent urethrolithiasis with associated urethral stricture managed with initial suprapubic tube and delayed primary end-to-end urethroplasty, excision of urethral stricture and urethral diverticulectomy.

  16. Blood Pressure Measurement: Clinic, Home, Ambulatory, and Beyond

    Science.gov (United States)

    Drawz, Paul E.; Abdalla, Mohamed; Rahman, Mahboob

    2014-01-01

    Blood pressure has traditionally been measured in the clinic setting using the auscultory method and a mercury sphygmomanometer. Technological advances have led to improvements in measuring clinic blood pressure and allowed for measuring blood pressures outside the clinic. This review outlines various methods for evaluating blood pressure and the clinical utility of each type of measurement. Home blood pressures and 24 hour ambulatory blood pressures have improved our ability to evaluate risk for target organ damage and hypertension related morbidity and mortality. Measuring home blood pressures may lead to more active participation in health care by patients and has the potential to improve blood pressure control. Ambulatory blood pressure monitoring enables the measuring nighttime blood pressures and diurnal changes, which may be the most accurate predictors of risk associated with elevated blood pressure. Additionally, reducing nighttime blood pressure is feasible and may be an important component of effective antihypertensive therapy. Finally, estimating central aortic pressures and pulse wave velocity are two of the newer methods for assessing blood pressure and hypertension related target organ damage. PMID:22521624

  17. Unusual giant prostatic urethral calculus | Bello | Journal of Surgical ...

    African Journals Online (AJOL)

    Giant vesico-prostatic urethral calculus is uncommon. Urethral stones rarely form primarily in the urethra, and they are usually associated with urethral strictures, posterior urethral valve or diverticula. We report a case of a 32-year-old man with giant vesico-prostatic (collar-stud) urethral stone presenting with sepsis and ...

  18. Management strategies for idiopathic urethritis.

    Science.gov (United States)

    Henderson, L; Farrelly, P; Dickson, A P; Goyal, A

    2016-02-01

    Williams and Mikhael (1971) described idiopathic urethritis (IU) as a self-limiting condition that affects boys aged 5-15 years, with symptoms of urethrorrhagia, dysuria and haematuria. However, a proportion of boys will remain symptomatic for several years, and may develop urethral stricture (Poch et al., 2007; Palagiri et al., 2003). There is no universally effective treatment for IU, although various strategies have been employed. To review the presentation and long-term outcomes of boys with IU, and present the efficacy of management strategies that have been utilised. A retrospective review was performed of all boys with IU. It was based on clinical and cystoscopic findings for presentation, medical history, management and clinical progress. Fifty-four boys were included, with a median age of 11 years (range 5-15 years) at presentation. The median duration of symptoms was 18 months (range 2-132 months). The median follow-up was 18.5 months (range 1-120 months). Seven (13.0%) boys had early urethral stricture at initial cystourethroscopy, and one (1.9%) developed stricture during follow-up. Thirty-six boys (66.7%) had previous circumcision and four (7.4%) had meatal stenosis. Eight (14.8%) had previous hypospadias repair. Whilst 50% of boys with IU do not require any specific treatment, those with severe/unremitting symptoms may benefit from a trial of urethral steroids or short-term urethral catheterisation. The mechanisms of benefit from these modalities are unclear and they require further evaluation. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  19. Prevalence and morbidity of urethral Trichomonas vaginalis in Japanese men with or without urethritis.

    Science.gov (United States)

    Seike, Kensaku; Maeda, Shin-Ichi; Kubota, Yasuaki; Tamaki, Masayoshi; Yasuda, Mitsuru; Deguchi, Takashi

    2013-09-01

    Trichomonas vaginalis is one of the pathogens causing sexually transmitted infections. This microorganism is a common pathogen among women, but its significance as a cause of morbidity among men remains uncertain. We sought to determine the prevalence and morbidity of T. vaginalis infection in Japanese men with and without urethritis. We examined urine specimens from 215 men with urethritis and 98 men without urethritis for the presence of urethral T. vaginalis by PCR assay. Only four patients-one with gonococcal urethritis, one with non-gonococcal chlamydial urethritis, one with non-gonococcal non-chlamydial urethritis and one without urethritis-were positive for T. vaginalis. The prevalence of T. vaginalis was 1.4% in men with urethritis and 1.0% in men without urethritis. A possible relation between the appearance of T. vaginalis and clinical symptoms was not confirmed. In the present study, the incidence of urethral T. vaginalis infection appears to be rare in Japanese men with or without urethritis, and T. vaginalis may be an uncommon pathogen in male urethritis in Japan.

  20. Sensing line effects on PWR-based differential pressure measurements

    International Nuclear Information System (INIS)

    Evans, R.P.; Neff, G.G.

    1982-01-01

    An incorrrect configuration of the fluid-filled pressure sensing lines connecting differential pressure transducers to the pressure taps in a pressurized water reactor system can cause errors in the measurement and, during rapid pressure transients, could cause the transducer to fail. Testing was performed in both static and dynamic modes to experimentally determine the effects of sensing lines of various lengths, diameters, and materials. Testing was performed at ambient temperature with absolute line pressures at about 17 MPa using water as the pressure transmission fluid

  1. Auscultatory versus oscillometric measurement of blood pressure in octogenarians

    DEFF Research Database (Denmark)

    Rosholm, Jens-Ulrik; Pedersen, Sidsel Arnspang; Matzen, Lars

    2012-01-01

    Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement.......Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement....

  2. Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm.

    Science.gov (United States)

    Goldstein, Lara Nicole; Wells, Mike; Sliwa, Karen

    2014-07-25

    Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically relevant (i.e. a difference of ≥10 mmHg). This was a prospective cross-sectional study in an urban ED making use of a convenience sample of 201 patients (18 - 50 years of age) who were not in need of emergency medical treatment. BP was measured in the supine position on both arms and ankles with the correct size cuff according to the manufacturer's guidelines. The arm and ankle BP measurements were compared. There was a clinically and statistically significant difference between arm and ankle systolic BP (SBP) and mean arterial pressure (MAP) (-13 mmHg, 95% confidence interval (CI) -28 - 1 mmHg and -5 mmHg, 95% CI -13 - 4 mmHg, respectively), with less difference in diastolic BP (DBP) (2 mmHg, 95% CI -7 - 10 mmHg). Only 37% of SBP measurements and 83% of MAP measurements were within an error range of 10 mmHg, while 95% of DBP measurements agreed within 10 mmHg. While the average differences (or the bias) were generally not large, large variations in individual patients (indicating poor precision) made the prediction of arm BP from ankle measurements unreliable. Ankle BP cannot be used as a substitute for arm BP in the ED.

  3. Measuring N2 Pressure Using Cyanobacteria

    Science.gov (United States)

    Silverman, S. N.; Kopf, S.; Gordon, R.; Bebout, B.; Som, S.

    2017-11-01

    We have shown that cyanobacteria can record information about N2 partial pressure both morphologically and isotopically, and thus may serve as useful geobarometers to help us better understand Earth's ancient atmosphere.

  4. Ionic conductivity measurements of zirconia under pressure using impedance spectroscopy

    International Nuclear Information System (INIS)

    Takebe, H; Sakamoto, D; Ohtaka, O; Fukui, H; Yoshiasa, A; Yamanaka, T; Ota, K; Kikegawa, T

    2002-01-01

    We have set up an electrical conductivity measurement system under high-pressure and high-temperature conditions with a multi-anvil high-pressure apparatus using an AC complex impedance method. With this system, we have successfully measured the electrical conductivity of stabilized ZrO 2 (Y 2 O 3 -ZrO 2 solid solution) under pressures up to 5 GPa in the temperature range from 300 to 1200 K. The electrical conductivities obtained under pressure are compatible with those of previous results measured at ambient pressure

  5. Automated measurement of pressure injury through image processing.

    Science.gov (United States)

    Li, Dan; Mathews, Carol

    2017-11-01

    To develop an image processing algorithm to automatically measure pressure injuries using electronic pressure injury images stored in nursing documentation. Photographing pressure injuries and storing the images in the electronic health record is standard practice in many hospitals. However, the manual measurement of pressure injury is time-consuming, challenging and subject to intra/inter-reader variability with complexities of the pressure injury and the clinical environment. A cross-sectional algorithm development study. A set of 32 pressure injury images were obtained from a western Pennsylvania hospital. First, we transformed the images from an RGB (i.e. red, green and blue) colour space to a YC b C r colour space to eliminate inferences from varying light conditions and skin colours. Second, a probability map, generated by a skin colour Gaussian model, guided the pressure injury segmentation process using the Support Vector Machine classifier. Third, after segmentation, the reference ruler - included in each of the images - enabled perspective transformation and determination of pressure injury size. Finally, two nurses independently measured those 32 pressure injury images, and intraclass correlation coefficient was calculated. An image processing algorithm was developed to automatically measure the size of pressure injuries. Both inter- and intra-rater analysis achieved good level reliability. Validation of the size measurement of the pressure injury (1) demonstrates that our image processing algorithm is a reliable approach to monitoring pressure injury progress through clinical pressure injury images and (2) offers new insight to pressure injury evaluation and documentation. Once our algorithm is further developed, clinicians can be provided with an objective, reliable and efficient computational tool for segmentation and measurement of pressure injuries. With this, clinicians will be able to more effectively monitor the healing process of pressure

  6. Unsteady pressures on a blunt trailing edge measured with an embedded pressure scanner

    Science.gov (United States)

    Naughton, Jonathan; Nikoueeyan, Pourya; Hind, Michael; Strike, John; Dahland, Matz; Keeter, Steven

    2017-11-01

    Development of direct-mount pressure scanners can decrease the pneumatic tubing length required to connect the measurement ports to the scanner manifold resulting in improved dynamic range for unsteady pressure measurements. In this work, the performance of a direct-mount pressure scanner for time-resolved pressure measurement is demonstrated in a well-established flow; the pressure fluctuations near the base of flat plate is considered. The additive manufactured model is instrumented with a pressure scanner and flush-mounted high-speed pressure transducers. The configuration of the ports on the model allows for side-by-side comparison of the pressures measured via embedded pneumatic tubing routed to a pressure scanner with that measured by high-speed transducers. Prior to testing, the dynamic response of each embedded pressure port is dynamically calibrated via an in-situ calibration technique. Pressure data is then acquired for fixed angle-of-attack and different dynamic pitching conditions. The dynamic range of the measurements acquired via direct-mount scanner will be compared to those acquired by the high speed transducers for both static and dynamic pitching configurations. The uncertainties associated with Weiner deconvolution are also quantified for the measurements.

  7. Clinical Characteristics of Herpes Simplex Virus Urethritis Compared With Chlamydial Urethritis Among Men.

    Science.gov (United States)

    Ong, Jason J; Morton, Anna N; Henzell, Helen R; Berzins, Karen; Druce, Julian; Fairley, Christopher K; Bradshaw, Catriona S; Read, Tim Rh; Hocking, Jane S; Chen, Marcus Y

    2017-02-01

    The aim of this study was to ascertain the clinical characteristics associated with herpes simplex virus (HSV) urethritis in men and to compare those with chlamydial urethritis. We compared clinical and laboratory data from men diagnosed with polymerase chain reaction confirmed HSV urethritis with those of men with chlamydial urethritis presenting to Melbourne Sexual Health Centre between 2000 and 2015. Eighty HSV urethritis cases were identified: 55 (68%, 95% confidence interval, 58-78) were by HSV-1 and 25 (32%, 95% confidence interval, 22-42) by HSV-2. Compared with chlamydial urethritis, men with HSV urethritis were significantly more likely to report severe dysuria (20% vs 0%, P < 0.01) or constitutional symptoms (15% vs 0%, P < 0.01). Men with HSV urethritis were significantly more likely to have meatitis (62% vs 23%, P < 0.01), genital ulceration (37% vs 0%, P < 0.01), or inguinal lymphadenopathy (30% vs 0%, P < 0.01) but less likely to have urethral discharge (32% vs 69%, P < 0.01). There was no significant difference in the proportion of men who had raised (≥5) polymorphonuclear leukocytes per high-powered field between the two groups (P = 0.46). The clinical presentation of HSV urethritis in men may differ from those of chlamydial urethritis and guide testing for HSV in men presenting with non-gonococcal urethritis.

  8. Urethral Leiomyoma: A Rare Clinical Entity

    Directory of Open Access Journals (Sweden)

    Ng Beng Kwang

    2016-01-01

    Full Text Available Extrauterine leiomyomas are encountered occasionally, which can pose a diagnostic dilemma and challenge to the gynaecologist. We report a rare case of urethral leiomyoma. A 31-year-old woman with history of primary subfertility presented with mass at her urethral meatus and lower urinary tract symptoms. She underwent examination under anaesthesia and excision of the urethral mass. Histopathological examination confirmed leiomyoma. Diagnosis and management of this common growth situated at a rare location were reviewed and discussed.

  9. Infectious Urethritis in Men and Women

    Science.gov (United States)

    Meares, Edwin M.

    1975-01-01

    Acute and recurrent infectious urethritis in men and women is commonly seen by physicians. Since specific therapy varies widely with the type of urethritis present, the proper diagnosis must be clearly established if curative drug therapy is to be selected. It is valuable, therefore, to review the diagnosis and therapy of the various forms of infectious urethritis that are recognized today in both men and women. PMID:1199099

  10. Various high precision measurements of pressure in atomic energy industry

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Inoue, Akira; Hosoma, Takashi; Tanaka, Izumi; Gabane, Tsunemichi.

    1987-01-01

    As for the pressure measurement in atomic energy industry, it is mostly the measurement using differential pressure transmitters and pressure transmitters for process measurement with the general accuracy of measurement of 0.2 - 0.5 % FS/year. However, recently for the development of nuclear fusion reactors and the establishment of nuclear fuel cycle accompanying new atomic energy technology, there are the needs of the pressure measurement having higher accuracy of 0.01 % FS/year and high resolution, and quartz vibration type pressure sensors appeared. New high accuracy pressure measurement techniques were developed by the advance of data processing and the rationalization of data transmission. As the results, the measurement of the differential pressure of helium-lithium two-phase flow in the cooling system of nuclear fusion reactors, the high accuracy measuring system for the level of plutonium nitrate and other fuel substance in tanks in fuel reprocessing and conversion, the high accuracy measurement of atmospheric pressure and wind velocity in ducts, chimneys and tunnels in nuclear facilities and so on became feasible. The principle and the measured data of quartz vibration type pressure sensors are shown. (Kako, I.)

  11. Acoustic sensor for remote measuring of pressure

    Directory of Open Access Journals (Sweden)

    Kataev V. F.

    2008-04-01

    Full Text Available The paper deals with sensors based on delay lines on surface acoustic waves (SAW, having a receiving-emitting and a reflective interdigital transducers (IDT. The dependence of the reflection coefficient of SAW on type and intensity of the load was studied. The authors propose a composite delay line in which the phase of the reflection coefficient depends on the pressure. Pressure leads to a shift of the reflective IDT relative to the transceiver, because they are located on different substrates. The paper also presents functional diagrams of the interrogator.

  12. Measuring infrared contributions to the QCD pressure

    CERN Document Server

    Kajantie, Keijo; Rummukainen, K; Schröder, Y

    2002-01-01

    For the pressure (or free energy) of QCD, four-dimensional (4d) lattice data is available at zero baryon density up to a few times the critical temperature $T_c$. Perturbation theory, on the other hand, has serious convergence problems even at very high temperatures. In a combined analytical and three-dimensional (3d) lattice method, we show that it is possible to compute the QCD pressure from about $2 T_c$ to infinity. The numerical accuracy is good enough to resolve in principle, e.g., logarithmic contributions related to 4-loop perturbation theory.

  13. Pressure field in measurement section of wind tunnel

    Directory of Open Access Journals (Sweden)

    Hnidka Jakub

    2017-01-01

    Full Text Available The University of Defence in Brno has a new low-speed wind tunnel. In order to confirm the quality of the wind inside of the measurement section, several measurements of the dynamic pressure have been performed with the Pitot-static tube. The pressure fields are then analysed and quality of the field is evaluated. Measurement of a pressure drop on the body of a standing helicopter was conducted.

  14. Hybrid optical unobtrusive blood pressure measurements

    NARCIS (Netherlands)

    Zhang, G.; Shan, C.; Kirenko, I.; Long, X.; Aarts, R.M.

    2017-01-01

    Blood pressure (BP) is critical in diagnosing certain cardiovascular diseases such as hypertension. Some previous studies have proved that BP can be estimated by pulse transit time (PTT) calculated by a pair of photoplethysmography (PPG) signals at two body sites. Currently, contact PPG (cPPG) and

  15. The promise of urethral pressure reflectometry

    DEFF Research Database (Denmark)

    Khayyami, Yasmine; Klarskov, Niels; Lose, Gunnar

    2016-01-01

    consists of a 45-cm-long PVC tube connected to a thin and highly flexible polyurethane bag, which is placed in the urethra. When inserted, the bag only occupies 0.4 mm(2) of the urethra, respecting the natural shape and orientation of the urethra and, most importantly; respecting the laws of physics when...

  16. Heat transfer and pressure measurements for the SSME fuel turbine

    Science.gov (United States)

    Dunn, Michael G.; Kim, Jungho

    1991-01-01

    A measurement program is underway using the Rocketdyne two-stage Space Shuttle Main Engine (SSME) fuel turbine. The measurements use a very large shock tunnel to produce a short-duration source of heated and pressurized gas which is subsequently passed through the turbine. Within this environment, the turbine is operated at the design values of flow function, stage pressure ratio, stage temperature ratio, and corrected speed. The first stage vane row and the first stage blade row are instrumented in both the spanwise and chordwise directions with pressure transducers and heat flux gages. The specific measurements to be taken include time averaged surface pressure and heat flux distributions on the vane and blade, flow passage static pressure, flow passage total pressure and total temperature distributions, and phase resolved surface pressure and heat flux on the blade.

  17. A method enabling simultaneous pressure and temperature measurement using a single piezoresistive MEMS pressure sensor

    International Nuclear Information System (INIS)

    Frantlović, Miloš; Stanković, Srđan; Jokić, Ivana; Lazić, Žarko; Smiljanić, Milče; Obradov, Marko; Vukelić, Branko; Jakšić, Zoran

    2016-01-01

    In this paper we present a high-performance, simple and low-cost method for simultaneous measurement of pressure and temperature using a single piezoresistive MEMS pressure sensor. The proposed measurement method utilizes the parasitic temperature sensitivity of the sensing element for both pressure measurement correction and temperature measurement. A parametric mathematical model of the sensor was established and its parameters were calculated using the obtained characterization data. Based on the model, a real-time sensor correction for both pressure and temperature measurements was implemented in a target measurement system. The proposed method was verified experimentally on a group of typical industrial-grade piezoresistive sensors. The obtained results indicate that the method enables the pressure measurement performance to exceed that of typical digital industrial pressure transmitters, achieving at the same time the temperature measurement performance comparable to industrial-grade platinum resistance temperature sensors. The presented work is directly applicable in industrial instrumentation, where it can add temperature measurement capability to the existing pressure measurement instruments, requiring little or no additional hardware, and without adverse effects on pressure measurement performance. (paper)

  18. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    Science.gov (United States)

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  19. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    Science.gov (United States)

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  20. Measuring sub-bandage pressure: comparing the use of pressure monitors and pulse oximeters.

    Science.gov (United States)

    Satpathy, A; Hayes, S; Dodds, S R

    2006-03-01

    To test the use of low-cost sub-bandage pressure monitors and pulse oximeters as part of a quality-control measure for graduated compression bandaging in leg ulcer clinics. Twenty-five healthy volunteers (mean age 40 years) providing 50 limbs were bandaged with a four-layer compression bandaging system. The ankle systolic pressure (ASP) was measured using a pulse oximeter (Nellcor NBP-40) before applying the graduated compression bandages. Interface pressure was measured by placing pressure sensors on the skin at three points (2cm above the medial malleolus; the widest part of the calf; and a point midway between them) in the supine and standing positions. The ASP was measured again with the pulse oximeter after the bandage had been applied, and the effect of the bandage on the ASP was recorded. The actual pressure created by the bandage was compared with the required pressure profile. Interface pressures varied with change of position and movement. With the operator blinded to the pressure monitors while applying the bandages, the target pressure of 35-40mmHg at the ankle was achieved in only 36% of limbs ([mean +/- 95% confidence interval]; 32.3 +/- 1.6mmHg [supine]; 38.4 +/- 2.4mmHg [standing position]). With the help of the pressure monitors, the target pressure was achieved in 78% of the limbs. There was no correlation between the pressure monitors and pulse oximeter pressures, demonstrating that the pulse oximeter is not a useful tool for measuring sub-bandage pressures. The results suggest a tool (interface pressure monitors) that is easy to operate should be available as part of quality assurance for treatment, training of care providers and education.

  1. Pressure History Measurement in a Microwave Beaming Thruster

    International Nuclear Information System (INIS)

    Oda, Yasuhisa; Ushio, Masato; Komurasaki, Kimiya; Takahashi, Koji; Kasugai, Atsushi; Sakamoto, Keishi

    2006-01-01

    In a microwave beaming thruster with a 1-dimensional nozzle, plasma and shock wave propagates in the nozzle absorbing microwave power. In this study, pressure histories in the thruster are measured using pressure gauges. Measured pressure history at the thruster wall shows constant pressure during plasma propagation in the nozzle. The result of measurement of the propagating velocities of shock wave and plasma shows that both propagate in the same velocity. These result shows that thrust producing model of analogy of pulse detonation engine is successful for the 1D thruster

  2. Peyronie's disease after urethral swab, an unusual complication: a case report

    Directory of Open Access Journals (Sweden)

    Paulis G

    2015-11-01

    Full Text Available Gianni Paulis,1,2 Davide Barletta3 1Andrology Center, Regina Apostolorum Hospital, Albano Laziale, Rome, Italy; 2Castelfidardo Medical Team, Peyronie's Disease Care Center, Rome, Italy; 3Department of Urology, Andrology Center, San Matteo Hospital, Pavia, Italy Abstract: Urethral swabs are still currently used as a diagnostic tool when urethritis or prostatitis are suspected. Urologists are certainly aware that Peyronie's disease may occur after traumatic urethral instrumentation (catheterization, urethrocystoscopy, etc, but onset of Peyronie's disease after urethral swab for diagnostic purposes has never been reported in the literature. This paper presents the case of a patient who developed Peyronie's disease after a clumsy urethral swab insertion. It is an unusual, and to date unreported, complication which we would like to call attention to. In the case of our patient, the swab had been inserted to a greater depth than normally required and strong pressure had also been applied. During the procedure, the patient experienced severe urethral and penile pain, which was followed by urethrorrhagia, and later penile curvature. The patient was treated conservatively with good results, partly because the disease was still in its active stage and not yet stable. In the light of what we report, when ordering a urethral swab, physicians should always recommend that it be performed at testing centers that follow accurate, rigorous standards. Patients should also be informed that the test they are to undergo consists of a swab being inserted into the urethra for a short distance, not more than 2–3 cm. Keywords: genitourinary trauma, penile curvature, Peyronie, urethral swab

  3. Pressurized transient otoacoustic emissions measured using click and chirp stimuli.

    Science.gov (United States)

    Keefe, Douglas H; Patrick Feeney, M; Hunter, Lisa L; Fitzpatrick, Denis F; Sanford, Chris A

    2018-01-01

    Transient-evoked otoacoustic emission (TEOAE) responses were measured in normal-hearing adult ears over frequencies from 0.7 to 8 kHz, and analyzed with reflectance/admittance data to measure absorbed sound power and the tympanometric peak pressure (TPP). The mean TPP was close to ambient. TEOAEs were measured in the ear canal at ambient pressure, TPP, and fixed air pressures from 150 to -200 daPa. Both click and chirp stimuli were used to elicit TEOAEs, in which the incident sound pressure level was constant across frequency. TEOAE levels were similar at ambient and TPP, and for frequencies from 0.7 to 2.8 kHz decreased with increasing positive and negative pressures. At 4-8 kHz, TEOAE levels were larger at positive pressures. This asymmetry is possibly related to changes in mechanical transmission through the ossicular chain. The mean TEOAE group delay did not change with pressure, although small changes were observed in the mean instantaneous frequency and group spread. Chirp TEOAEs measured in an adult ear with Eustachian tube dysfunction and TPP of -165 daPa were more robust at TPP than at ambient. Overall, results demonstrate the feasibility and clinical potential of measuring TEOAEs at fixed pressures in the ear canal, which provide additional information relative to TEOAEs measured at ambient pressure.

  4. Innovations in plantar pressure and foot temperature measurements in diabetes

    NARCIS (Netherlands)

    Bus, S. A.

    2016-01-01

    Plantar pressure and temperature measurements in the diabetic foot primarily contribute to identifying abnormal values that increase risk for foot ulceration, and they are becoming increasingly more integrated in clinical practice and daily life of the patient. While plantar pressure measurements

  5. Investigating the mechanism underlying urinary continence recovery after radical prostatectomy: effectiveness of a longer urethral stump to prevent urinary incontinence.

    Science.gov (United States)

    Kadono, Yoshifumi; Nohara, Takahiro; Kawaguchi, Shohei; Naito, Renato; Urata, Satoko; Nakashima, Kazufumi; Iijima, Masashi; Shigehara, Kazuyoshi; Izumi, Kouji; Gabata, Toshifumi; Mizokami, Atsushi

    2018-02-28

    To assess the chronological changes in urinary incontinence and urethral function before and after radical prostatectomy (RP), and to compare the findings of pelvic magnetic resonance imaging (MRI) before and after RP to evaluate the anatomical changes. In total, 185 patients were evaluated with regard to the position of the distal end of the membranous urethra (DMU) on a mid-sagittal MRI slice and urethral sphincter function using the urethral pressure profilometry. The patients also underwent an abdominal leak point pressure test before RP and at 10 days and 12 months after RP. The results were then compared with the chronological changes in urinary incontinence. The MRI results showed that the DMU shifted proximally to an average distance of 4 mm at 10 days after RP and returned to the preoperative position at 12 months after RP. Urethral sphincter function also worsened 10 days after RP, with recovery after 12 months. The residual length of the urethral stump and urinary incontinence were significantly associated with the migration length of the DMU at 10 days after RP. The residual length of the urethral stump was a significant predictor of urinary incontinence after RP. This is the first study to elucidate that the slight vertical repositioning of the membranous urethra after RP causes chronological changes in urinary incontinence. A long urethral residual stump reduces urinary incontinence after RP. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  6. Differential Intracochlear Sound Pressure Measurements in Normal Human Temporal Bones

    Science.gov (United States)

    Nakajima, Hideko Heidi; Dong, Wei; Olson, Elizabeth S.; Merchant, Saumil N.; Ravicz, Michael E.; Rosowski, John J.

    2009-02-01

    We present the first simultaneous sound pressure measurements in scala vestibuli and scala tympani of the cochlea in human cadaveric temporal bones. Micro-scale fiberoptic pressure sensors enabled the study of differential sound pressure at the cochlear base. This differential pressure is the input to the cochlear partition, driving cochlear waves and auditory transduction. Results showed that: pressure of scala vestibuli was much greater than scala tympani except at low and high frequencies where scala tympani pressure affects the input to the cochlea; the differential pressure proved to be an excellent measure of normal ossicular transduction of sound (shown to decrease 30-50 dB with ossicular disarticulation, whereas the individual scala pressures were significantly affected by non-ossicular conduction of sound at high frequencies); the middle-ear gain and differential pressure were generally bandpass in frequency dependence; and the middle-ear delay in the human was over twice that of the gerbil. Concurrent stapes velocity measurements allowed determination of the differential impedance across the partition and round-window impedance. The differential impedance was generally resistive, while the round-window impedance was consistent with a compliance in conjunction with distributed inertia and damping. Our techniques can be used to study inner-ear conductive pathologies (e.g., semicircular dehiscence), as well as non-ossicular cochlear stimulation (e.g., round-window stimulation) - situations that cannot be completely quantified by measurements of stapes velocity or scala-vestibuli pressure by themselves.

  7. Full scale measurement of wind induced pressures : 1 configuration of wind induced pressures

    NARCIS (Netherlands)

    Geurts, C.P.W.; Wijen, H.L.M.

    1994-01-01

    A research project 10 the spectral characteristics of wind induced pressures is in progress in Eindhoven. This project includes both wind tunnel and full scale measurements. Wind induced pressures are measured in full scale at the main building of Eindhoven University of Technology. This paper

  8. The optimal scheme of self blood pressure measurement as determined from ambulatory blood pressure recordings

    NARCIS (Netherlands)

    Verberk, Willem J.; Kroon, Abraham A.; Kessels, Alfons G. H.; Lenders, Jacques W. M.; Thien, Theo; van Montfrans, Gert A.; Smit, Andries J.; de Leeuw, Peter W.

    Objective To determine how many self-measurements of blood pressure (BP) should be taken at home in order to obtain a reliable estimate of a patient's BP. Design Participants performed self blood pressure measurement (SBPM) for 7 days (triplicate morning and evening readings). In all of them, office

  9. Velocity-pressure correlation measurements in complex free shear flows

    International Nuclear Information System (INIS)

    Naka, Yoshitsugu; Obi, Shinnosuke

    2009-01-01

    Simultaneous measurements of fluctuating velocity and pressure were performed in various turbulent free shear flows including a turbulent mixing layer and the wing-tip vortex trailing from a NACA0012 half-wing. Two different methods for fluctuating static pressure measurement were considered: a direct method using a miniature Pitot tube and an indirect method where static pressure was calculated from total pressure. The pressure obtained by either of these methods was correlated with the velocity measured by an X-type hot-wire probe. The results from these two techniques agreed with each other in the turbulent mixing layer. In the wing-tip vortex case, however, some discrepancies were found, although overall characteristics of the pressure-related statistics were adequately captured by both methods.

  10. Modern gas-based temperature and pressure measurements

    CERN Document Server

    Pavese, Franco

    2013-01-01

    This 2nd edition volume of Modern Gas-Based Temperature and Pressure Measurements follows the first publication in 1992. It collects a much larger set of information, reference data, and bibliography in temperature and pressure metrology of gaseous substances, including the physical-chemical issues related to gaseous substances. The book provides solutions to practical applications where gases are used in different thermodynamic conditions. Modern Gas-Based Temperature and Pressure Measurements, 2nd edition is the only comprehensive survey of methods for pressure measurement in gaseous media used in the medium-to-low pressure range closely connected with thermometry. It assembles current information on thermometry and manometry that involve the use of gaseous substances which are likely to be valid methods for the future. As such, it is an important resource for the researcher. This edition is updated through the very latest scientific and technical developments of gas-based temperature and pressure measurem...

  11. Balloon dilatation of iatrogenic urethral strictures

    International Nuclear Information System (INIS)

    Acunas, B.; Acunas, G.; Gokmen, E.; Celik, L.

    1988-01-01

    Balloon dilatation of the urethra was performed in five patients with iatrogenic urethral strictures. The urethral strictures were successfully negotiated and dilated in all patients. Redilatation became necessary in a period ranging from 3 to 10 months. The authors believe that balloon dilatation of the urethra can be safely and successfully performed; the procedure produces minimal trauma and immediate relief of symptoms. (orig.)

  12. Hydraulic urethral dilatation after optical internal urethrotomy ...

    African Journals Online (AJOL)

    Objectives: To determine the rate of early recurrence of urethral stricture in the first six months in patients who perform hydraulic urethral dilatation(HUD) after optical internal urethrotomy (OIU) and compare the early recurrence Fate in patients who perform HUD after OIU with the recurrence rates in patients reported in the ...

  13. [Transurethral thulium laser urethrotomy for urethral stricture].

    Science.gov (United States)

    Liu, Chun-Lai; Zhang, Xi-Ling; Liu, Yi-Li; Wang, Ping

    2011-09-01

    To evaluate the effect of endourethrotomy with thulium laser as a minimally invasive treatment for urethral stricture. We treated 36 cases of urethral stricture or atresia by endourethrotomy with thulium laser, restored the urethral continuity by vaporization excision of the scar tissue, and observed the clinical effects and complications. The mean operation time was 35 min, ranging from 10 to 90 min. Smooth urination was achieved after 2-6 weeks of catheter indwelling, with no urinary incontinence. The patients were followed up for 4-24 (mean 12) months, during which 27 did not need any reintervention, 5 developed urinary thinning but cured by urethral dilation, 3 received another laser urethrotomy for previous negligence of timely urethral dilation, and the other 1 underwent open urethroplasty. Thulium laser urethrotomy is a safe and effective minimally invasive option for short urethral stricture, which is also suitable for severe urethral stricture and urethral atresia. Its short-term outcome is satisfactory, but its long-term effect remains to be further observed.

  14. Azithromycin Failure in Mycoplasma genitalium Urethritis

    Science.gov (United States)

    Jensen, Jorgen S.; Tabrizi, Sepehr N.; Read, Timothy R.H.; Garland, Suzanne M.; Hopkins, Carol A.; Moss, Lorna M.; Fairley, Christopher K.

    2006-01-01

    We report significant failure rates (28%, 95% confidence interval 15%–45%) after administering 1 g azithromycin to men with Mycoplasma genitalium–positive nongonococcal urethritis. In vitro evidence supported reduced susceptibility of M. genitalium to macrolides. Moxifloxacin administration resulted in rapid symptom resolution and eradication of infection in all cases. These findings have implications for management of urethritis. PMID:16836839

  15. Reactive arthritis associated with Mycoplasma genitalium urethritis.

    Science.gov (United States)

    Chrisment, D; Machelart, I; Wirth, G; Lazaro, E; Greib, C; Pellegrin, J-L; Bébéar, C; Peuchant, O

    2013-11-01

    Mycoplasma genitalium is an important cause of sexually transmitted infections that is gaining recognition and is an independent cause of acute and chronic nongonococcal urethritis in men. M. genitalium has been implicated as a possible causative factor in reactive arthritis. We report a case of reactive arthritis complicating M. genitalium urethritis in an HLA-B27-positive patient. © 2013.

  16. Corynebacterium propinquum associated with acute, nongonococcal urethritis.

    Science.gov (United States)

    Abdolrasouli, Alireza; Roushan, Azita

    2013-10-01

    Corynebacterium propinquum is usually considered part of the normal human oropharyngeal flora and is rarely responsible for clinical infection. We report here what seems to be the first case of acute purulent urethral discharge in a young Iranian man with urethritis acquired after orogenital contact. Attention should be devoted to less common nondiphtheriae Corynebacterium species for differential diagnosis.

  17. Bladder exstrophy associated with complete urethral duplication ...

    African Journals Online (AJOL)

    J.E. Mensah

    ees.elsevier.com/afju · www.sciencedirect.com. Case report. Bladder exstrophy associated with complete urethral duplication: Bladder can be augmented with dorsal urethral mucosa. J.E. Mensaha,∗. , K.N. Ampadua, M.Y. Kyeia, B. Edusieb.

  18. The diastal urethral stenosis in female children

    International Nuclear Information System (INIS)

    Pauer, W.

    1985-01-01

    The distal urethral stenosis in female children is a pathological reality. It is represented by the hymenal hood, the meatal stenosis and the distal urethral ring. Diagnosis and localisation of the stenosis is maintained by calibration with bougies a boule. Therapeutical consequences are: internal urethrotomy, bilateral meatotomy and excision of hymenal hoods. (Author)

  19. Contemporary Management of Primary Distal Urethral Cancer

    NARCIS (Netherlands)

    Traboulsi, S.L.; Witjes, J.A.; Kassouf, W.

    2016-01-01

    Primary urethral cancer is one of the rare urologic tumors. Distal urethral tumors are usually less advanced at diagnosis compared with proximal tumors and have a good prognosis if treated appropriately. Low-stage distal tumors can be managed successfully with a surgical approach in men or radiation

  20. Intraocular pressure measurement in patients with previous LASIK surgery using pressure phosphene tonometer.

    Science.gov (United States)

    Cheng, Arthur C K; Leung, Dexter Y L; Cheung, Eva Y Y; Fan, Dorothy S P; Law, Ricky W K; Lam, Dennis S C

    2005-04-01

    To compare intraocular pressure (IOP) assessment in post-LASIK patients using non-contact tonometry, pressure phosphene tonometry and applanation tonometry. Sixty-two consecutive LASIK patients were analysed preoperatively and postoperatively with non-contact, pressure phosphene and applanation tonometry. Comparisons among these values were assessed with paired sample Student t-test, Pearson's correlation test and Bland-Altman plotting. There was no significant difference for preoperative IOP measurement between non-contact, pressure phosphene and applanation tonometry. The mean +/-SD difference between the preoperative non-contact tonometry and postoperative pressure phosphene tonometry IOP measurements was 0.80 +/- 2.77 mmHg (P contact tonometry significantly underestimated IOP measurement by 9.96 +/- 2.25 mmHg (P < 0.001). Pressure phosphene tonometry may provide an alternative method for the assessment of IOP in post-LASIK patients.

  1. A clinicopathological study of urethritis in males.

    Science.gov (United States)

    Saleem, Khawer; Mumtaz, Babar; Raza, Naeem

    2009-12-01

    To determine the etiology and frequency of different types of urethritis in adult males. A case series. The Dermatology Department of PNS Shifa Hospital, Karachi, from June 2004 to December 2007. One hundred male patients having complaints of urethral discharge and dysuria reporting in the skin OPD were included in the study. Patients who had received systemic treatment for their complaints and those who had other systemic infections were excluded. A detailed history including history of sexual contact was taken. Dermatological examination including examination of external genitalia was also performed. All these patients were subjected to complete physical examination, complete urine examination, urethral pus for gram staining and culture, endo-urethral swab with urethral loop for seeing Chlamydia antigen by fluorescent microscopy, cultures for ureaplasma and Wet mount specimen microscopy for trichomonas along with HIV (serum ELISA) test. Non-gonococcal urethritis was diagnosed on the presence of more than five polymorphonuclear leucocytes per high power field in at least five fields of Gram stained urethral smear, in the absence of Gram negative diplococci. The mean age was 29.2 + or - 5.8 years. Seventy (70%) cases were diagnosed as gonococcal urethritis and 30 (30%) cases as non-gonococcal urethritis (NGU). History of illicit sexual exposure was available in 25 (25%) patients. The interval period between initiation of symptoms and reporting of patient in gonococcal urethritis was 4 to 30 days (mean 12.8 days) and 4 days to 2 months (mean 20.7 days) in non-gonococcal urethritis. The patients with gonococcal urethritis presented with purulent discharge in 66 (84%) cases, and dysuria in 49 (70%) cases. In the NGU group, 25 (80%) cases had mucoid discharge and 18 (65%) had dysuria. in 70%, Neisseria gonorrhoeae was isolated, Chlamydia trachomatis in 16%, ureaplasma in 8%, and Trichomonas vaginalis in 4%. No organism could be detected in 2% cases. HIV test was

  2. Imaging of the female urethral diverticulum

    International Nuclear Information System (INIS)

    Singla, P.; Long, S.S.; Long, C.M.; Genadry, R.R.; Macura, K.J.

    2013-01-01

    Female urethral diverticulum is a localized out-pouching of the urethra that is becoming increasingly prevalent, but often poses a diagnostic challenge. Traditionally, conventional voiding cystourethrography has been used to make the preoperative diagnosis. With the development of higher-resolution images acquired through ultrasonography (US), computed tomography (CT), and magnetic resonance imaging (MRI), the anatomy and various abnormalities of the female urethra can be better elucidated. This article focuses on the imaging features of female urethral diverticulum, with emphasis on diagnostic pearls, particularly using MRI. Female urethral diverticulum can be best identified by their location in the posterolateral urethra and by their communication with the urethral lumen. Improved imaging techniques combined with increased physician awareness of urethral diverticulum will lead to more prompt and accurate diagnosis of this entity, leading to better treatment of affected patients

  3. URETHROPLASTY FOR COMPLICATED ANTERIOR URETHRAL STRICTURES.

    Science.gov (United States)

    Aoki, Katsuya; Hori, Shunta; Morizawa, Yosuke; Nakai, Yasushi; Miyake, Makito; Anai, Satoshi; Torimoto, Kazumasa; Yoneda, Tatsuo; Tanaka, Nobumichi; Yoshida, Katsunori; Fujimoto, Kiyohide

    2016-01-01

    (Objectives) To compare efficacy and outcome of urethroplasty for complicated anterior urethral strictures. (Methods) Twelve patients, included 3 boys, with anterior urethral stricture underwent urethroplasty after the failure of either urethral dilatation or internal urethrotomy. We evaluated pre- and post-operative Q max and surgical outcome. (Results) Four patients were treated with end-to-end anastomosis, included a case of bulbar urethral elongation simultaneously, one patient was treated with augmented anastomotic urethroplasty, three patients were treated with onlay urethroplasty with prepucial flap, one patient was treated with tubed urethroplasty with prepucial flap (Ducket procedure) and three patients were treated with onlay urethroplasty with buccal mucosal graft. Postoperative Qmax improved in all patients without major complications and recurrence during follow-up periods ranging from 17 to 102 months (mean 55 months). (Conclusions) Urethroplasty is an effective therapeutic procedure for complicated anterior urethral stricture.

  4. Measurements of the Exerted Pressure by Pelvic Circumferential Compression Devices

    Science.gov (United States)

    Knops, Simon P; van Riel, Marcel P.J.M; Goossens, Richard H.M; van Lieshout, Esther M.M; Patka, Peter; Schipper, Inger B

    2010-01-01

    Background: Data on the efficacy and safety of non-invasive Pelvic Circumferential Compression Devices (PCCDs) is limited. Tissue damage may occur if a continuous pressure on the skin exceeding 9.3 kPa is sustained for more than two or three hours. The aim of this study was to gain insight into the pressure build-up at the interface, by measuring the PCCD-induced pressure when applying pulling forces to three different PCCDs (Pelvic Binder® , SAM-Sling ® and T-POD® ) in a simplified model. Methods: The resulting exerted pressures were measured at four ‘anatomical’ locations (right, left, posterior and anterior) in a model using a pressure measurement system consisting of pressure cuffs. Results: The exerted pressure varied substantially between the locations as well as between the PCCDs. Maximum pressures ranged from 18.9-23.3 kPa and from 19.2-27.5 kPa at the right location and left location, respectively. Pressures at the posterior location stayed below 18 kPa. At the anterior location pressures varied markedly between the different PCCDs. Conclusion: The circumferential compression by the different PCCDs showed high pressures measured at the four locations using a simplified model. Difference in design and functional characteristics of the PCCDs resulted in different pressure build-up at the four locations. When following the manufacturer’s instructions, the exerted pressure of all three PCCDs tested exceeded the tissue damaging level (9.3 kPa). In case of prolonged use in a clinical situation this might put patients at risk for developing tissue damage. PMID:20361001

  5. [Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm].

    Science.gov (United States)

    Saul, F; Aristidou, Y; Klaus, D; Wiemeyer, A; Lösse, B

    1995-09-01

    Indirectly measured blood pressure at the wrist or upper arm was compared with directly measured values in the aortic arch during routinely performed diagnostic cardiac catheterization in 100 patients (31-80 years, mean 59.3 years, 60% males). The noninvasive measurements were carried out by oscillometric devices, NAiS Blood Pressure Watch for measurements at the wrist, and Hestia OZ80 at the upper arm. Systolic blood pressure measured at the wrist was 4.3 +/- 14.1 mm Hg, and the diastolic value 6.0 +/- 8.9 mm Hg higher than when measured at the aortic arch; the difference was significant in both cases. Correlation coefficients were 0.85 for systolic and 0.71 for diastolic blood pressure. In 16% of the patients the systolic blood pressure at the wrist differed more than +/- 20 mm Hg. The diastolic blood pressure at the wrist measured more than +/- 20 mm Hg higher than in the aorta in 5% of the patients. At the upper arm mean systolic values were not different to the aorta. The diastolic pressure was 9.3 +/- 9.8 mm Hg higher in the aorta than at the upper arm. To verify the accuracy of values measured with the NAiS Blood Pressure Watch compared with the standard technique at the upper arm, sequential measurements were made at wrist and ipsilateral upper arm in the same group of 100 patients. The systolic blood pressure at the left wrist was 3.4 +/- 13.3 mm Hg higher and the diastolic pressure 3.8 +/- 9.5 mm Hg lower than at the upper arm. Only 53% of systolic values lay within a range of +/- 10 mm Hg. The correspondence between wrist and upper arm values was better for diastolic blood pressure, the values differing by less than +/- 10 mm Hg in two-thirds of patients. Self-measurement of arterial blood pressure with an oscillometric device at the wrist can be recommended only in individual cases with a difference of simultaneously measured values at the upper arm of less than +/- 10 mm Hg for systolic and diastolic blood pressures. The standard method for indirectly

  6. Comparison of ambulatory blood pressure monitoring and office blood pressure measurements in obese children and adolescents.

    Science.gov (United States)

    Renda, Rahime

    2018-04-01

    Obesity in adults has been related to hypertension and abnormal nocturnal dipping of blood pressure, which are associated with poor cardiovascular and renal outcomes. Here, we aimed to resolve the relationship between the degree of obesity, the severity of hypertension and dipping status on ambulatory blood pressure in obese children. A total 72 patients with primary obesity aged 7 to 18 years (mean: 13.48 ± 3.25) were selected. Patients were divided into three groups based on body mass index (BMİ) Z-score. Diagnosis and staging of ambulatory hypertension based on 24-h blood pressure measurements, obtained from ambulatory blood pressure monitoring. Based on our ambulatory blood pressure data, 35 patients (48.6%) had hypertension, 7 (20%) had ambulatory prehypertension, 21 (60%) had hypertension, and 7 patients (20%) had severe ambulatory hypertension. There was a significant relationship between severity of hypertension and the degree of obesity (p lood pressure results and loads were similar between groups. Diastolic and mean arterial blood pressure levels during the night, diastolic blood pressure loads, and heart rate during the day were significantly higher in Group 3 (p lood pressure at night, mean arterial pressure at night, diastolic blood pressure loads and heart rate at day. Increase in BMI Z-score does not a significant impact on daytime blood pressure and nocturnal dipping status.

  7. Podophyllin induced urethral stricture in a young Nigerian male ...

    African Journals Online (AJOL)

    Urethral stricture is an abnormal narrowing or loss of distensibility due to fibrosis in the peri-urethral tissues. Some substances can induce chemical urethritis severe enough to cause stricture. We present a case of long segment anterior urethral stricture in a young Nigerian patient cause by self-application of podophyllin for ...

  8. Podophyllin induced urethral stricture in a young Nigerian male

    Directory of Open Access Journals (Sweden)

    P.O. Areo

    2015-09-01

    Full Text Available Urethral stricture is an abnormal narrowing or loss of distensibility due to fibrosis in the peri-urethral tissues. Some substances can induce chemical urethritis severe enough to cause stricture. We present a case of long segment anterior urethral stricture in a young Nigerian patient cause by self-application of podophyllin for the treatment of genital warts.

  9. Aetiology of Urethral Strictures at Moi Teaching and Refferal Hospital

    African Journals Online (AJOL)

    16.3 years. Conclusion. Urethritis, iatrogenic and accidental trauma are still the commonest causes of urethral strictures in our environment. These causes are preventable. Introduction. Urethral stricture disease is caused by any process that injures the urethral epithelium or the underlying spongiosum leading to healing by.

  10. Electrochemical noise measurements under pressurized water reactor conditions

    International Nuclear Information System (INIS)

    Van Nieuwenhove, R.

    2000-01-01

    Electrochemical potential noise measurements on sensitized stainless steel pressure tubes under pressurized water reactor (PWR) conditions were performed for the first time. Very short potential spikes, believed to be associated to crack initiation events, were detected when stressing the sample above the yield strength and increased in magnitude until the sample broke. Sudden increases of plastic deformation, as induced by an increased tube pressure, resulted in slower, high-amplitude potential transients, often accompanied by a reduction in noise level

  11. Using pressure square-like wave to measure the dynamic characteristics of piezoelectric pressure sensor

    International Nuclear Information System (INIS)

    Han, L-L; Tsung, T-T; Chen, L-C; Chang Ho; Jwo, C-S

    2005-01-01

    Piezoelectric pressure sensors are commonly used to measuring the dynamic characteristics in a hydraulic system. The dynamic measurements require a pressure sensor which has a high response rate. In this paper, we proposed use of a pressure square wave to excite the piezoelectric pressure sensor. Experimental frequencies are 0.5, 1.0, 1.5, and 2.0 kHz at 10, 15, 20 bar, respectively. Results show that the waveform of time-domain and frequencydomain response are quite different under above testing conditions. The higher the frequencies tested, the faster the pressure-rise speeds obtained. Similarly, the higher the testing pressure, the shorter the rise time attained

  12. [Invasive arterial blood pressure measurement using an aneroid pressure system in cattle].

    Science.gov (United States)

    Mosing, M; Franz, S; Iff, I; Schwendenwein, I

    2009-06-01

    The aim of this study was to compare the results of invasive arterial blood pressure measurement using an electronic pressure transducer (EPT) or an aneroid pressure system (APS) in cattle. A catheter was placed in the auricular artery of 11 adult cattle and connected to a pressure transducer via pressure line. The aneroid system was connected to the same catheter using a three-way stop-cock in the pressure line. On five occasions three consecutive measurements were performed with the APS. The mean blood pressure values of the EPT were recorded before each individual measurement. Values from each device were compared using Passing and Bablok regression of agreement and a Bland and Altman difference plot. One hundred and forty-seven paired measurements were analysed. The average bias between the two methods (EPT vs. APS) was -1.6 mmHg (95 % confidence interval [CI]: -3.0 to -0.2 mmHg). The coefficient of correlation was 1.0084. The aneroid system showed an almost perfect agreement with the EPT. This study shows that it can be used in a clinical setting as well as under field conditions to measure arterial blood pressure in cattle.

  13. A note on measurement of sound pressure with intensity probes

    DEFF Research Database (Denmark)

    Juhl, Peter; Jacobsen, Finn

    2004-01-01

    be improved under a variety of realistic sound field conditions by applying a different weighting of the two pressure signals from the probe. The improved intensity probe can measure the sound pressure more accurately at high frequencies than an ordinary sound intensity probe or an ordinary sound level meter......The effect of scattering and diffraction on measurement of sound pressure with "two-microphone" sound intensity probes is examined using an axisymmetric boundary element model of the probe. Whereas it has been shown a few years ago that the sound intensity estimated with a two-microphone probe...... is reliable up to 10 kHz when using 0.5 in. microphones in the usual face-to-face arrangement separated by a 12 mm spacer, the sound pressure measured with the same instrument will typically be underestimated at high frequencies. It is shown in this paper that the estimate of the sound pressure can...

  14. TREATMENT OF HYPERTENSION USING TELEMEDICAL HOME BLOOD PRESSURE MEASUREMENTS

    DEFF Research Database (Denmark)

    Hoffmann-Petersen, N; Lauritzen, T; Bech, J N

    2015-01-01

    OBJECTIVE: Telemonitoring of home blood pressure measurements (TBPM) is a new and promising supplement to diagnosis, control and treatment of hypertension. We wanted to compare the outcome of antihypertensive treatment based on TBPM and conventional monitoring of blood pressure. DESIGN AND METHOD...... of the measurements and subsequent communication by telephone or E-mail. In the control group, patients received usual care. Primary outcome was reduction in daytime ambulatory blood pressure measurements (ABPM) from baseline to 3 months' follow-up. RESULTS: In both groups, daytime ABPM decreased significantly....../181), p = 0.34. Blood pressure reduction in the TBPM group varied with the different practices. CONCLUSIONS: No further reduction in ABPM or number of patients reaching blood pressure targets was observed when electronic transmission of TBPM was applied in the treatment of hypertension by GPs. Thus...

  15. Blood pressure measurement: one arm or both arm?

    Science.gov (United States)

    Kulkarni, Prasad K; Shekhar, Susheela; Reddy, B N; Nirmala, B C

    2011-09-01

    Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.

  16. Pico gauges for minimally invasive intracellular hydrostatic pressure measurements

    DEFF Research Database (Denmark)

    Knoblauch, Jan; Mullendore, Daniel L.; Jensen, Kaare Hartvig

    2014-01-01

    Intracellular pressure has a multitude of functions in cells surrounded by a cell wall or similar matrix in all kingdoms of life. The functions include cell growth, nastic movements, and penetration of tissue by parasites. The precise measurement of intracellular pressure in the majority of cells......, however, remains difficult or impossible due to their small size and/or sensitivity to manipulation. Here, we report on a method that allows precise measurements in basically any cell type over all ranges of pressure. It is based on the compression of nanoliter and picoliter volumes of oil entrapped...... in the tip of microcapillaries, which we call pico gauges. The production of pico gauges can be accomplished with standard laboratory equipment, and measurements are comparably easy to conduct. Example pressure measurements are performed on cells that are difficult or impossible to measure with other methods....

  17. Maximum respiratory pressure measuring system : calibration and evaluation of uncertainty

    NARCIS (Netherlands)

    Ferreira, J.L.; Pereira, N.C.; Oliveira Júnior, M.; Vasconcelos, F.H.; Parreira, V.F.; Tierra-Criollo, C.J.

    2010-01-01

    The objective of this paper is to present a methodology for the evaluation of uncertainties in the measurements results obtained during the calibration of a digital manovacuometer prototype (DM) with a load cell sensor pressure device incorporated. Calibration curves were obtained for both pressure

  18. Definition-consistent measurement of exchange market pressure

    NARCIS (Netherlands)

    Klaassen, F.; Jager, H.

    2011-01-01

    Currencies can be under severe pressure, but in a managed exchange rate regime that is not fully visible via the change in the exchange rate. The literature has proposed a way to measure such exchange market pressure (EMP) indirectly, by adding interest rate changes and forex interventions to the

  19. Blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, Christina H.; Toftegaard, Thomas Skjødeberg

    2013-01-01

    a reliable blood pressure reading. Results: We found that the patients did not adhere to given instructions when performing blood pressure self-measurement in the waiting room. None of the 81 patients adhered to all six inves- tigated recommendations, while around a quarter adhered to five out of six...

  20. New Technique of Direct Intra-abdominal Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Elena Risin

    2006-10-01

    Conclusion: Direct measurement of intra-abdominal pressure using 14-Fr PVC round drain is a newly described technique that is simple, fast and credible. Future investigation will be needed to confirm the reliability of this method during postoperative follow-up of intra-abdominal pressures in selected patients.

  1. Noninvasive microbubble-based pressure measurements: a simulation study

    NARCIS (Netherlands)

    Postema, Michiel; Postema, M.A.B.; Bouakaz, Ayache; de Jong, N.

    2004-01-01

    This paper describes a noninvasive method to measure local hydrostatic pressures in fluid filled cavities. The method is based on the disappearance time of a gas bubble, as the disappearance time is related to the hydrostatic pressure. When a bubble shrinks, its response to ultrasound changes. From

  2. Gain measurements in CO2 CW low pressure lasers

    International Nuclear Information System (INIS)

    Rodrigues, N.A.S.; Chanes Junior, J.B.; Jayaram, K.

    1983-01-01

    A series of gain measurements in low pressure CO 2 CW laser were performed in order to study the behaviour of a CO 2 laser ampliflier as a function of pressure and discharge current. A theoretical model, based on rate equations is also presented to describe the laser behaviour and the experimental procedure adopted. (C.L.B.) [pt

  3. Surgical management of urethral prolapse in girls: 13 years' experience.

    Science.gov (United States)

    Holbrook, Charlotte; Misra, Devesh

    2012-07-01

    Study Type - Therapy (case series) Level of Evidence 4 What's known on the subject? and What does the study add? Urethral prolapse (UP) is a rare condition, with a suggested incidence of one in 3000. It occurs most often in prepubertal, primarily Black, girls. The underlying cause of this condition remains uncertain, although a lack of oestrogen is thought to have a role, owing to the preponderance of the condition in the prepubertal and postmenopausal age groups. A popular theory is that the problem arises as a consequence of poor attachments between the two layers of smooth muscle surrounding the urethra, combined with episodic increases in intraabdominal pressure. The most common presentation of UP is genital bleeding or a mass. The classical appearance of UP (i.e. the 'doughnut' sign) enables diagnosis to be made easily on clinical grounds alone. Optimum management of UP is less certain, with opinion divided on the merits of conservative therapy vs surgical excision. Conservative therapy aims to reduce mucosal oedema, improve local hygiene and counteract lack of oestrogen by using a combination of any or all of the following: Sitz baths, topical oestrogen cream, antibacterial wash/soap and topical antibiotics. Surgical management of UP involves excision of the prolapsed mucosa circumferentially. Several authors have reported success with surgical excision, but it carries a risk of developing stenosis of the urethral opening. The present study supports previously reported findings by other authors in terms of demographics and clinical presentation. Patient ages ranged from 2 to 15 years and all girls were of Black race. They most commonly presented with a mass (8/21 patients) or bleeding (6/21 patients) and diagnosis was confirmed on clinical examination, although one required a general anaesthetic (GA) to complete the examination. The present study shows that, in mild cases (usually where there is a mass without symptoms), UP can be successfully managed using

  4. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

    Directory of Open Access Journals (Sweden)

    Glik Zehava

    2009-10-01

    Full Text Available Abstract Background Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. Methods In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1 determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2 discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. Results Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. Conclusion The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.

  5. Development of a Blood Pressure Measurement Instrument with Active Cuff Pressure Control Schemes

    Directory of Open Access Journals (Sweden)

    Chung-Hsien Kuo

    2017-01-01

    Full Text Available This paper presents an oscillometric blood pressure (BP measurement approach based on the active control schemes of cuff pressure. Compared with conventional electronic BP instruments, the novelty of the proposed BP measurement approach is to utilize a variable volume chamber which actively and stably alters the cuff pressure during inflating or deflating cycles. The variable volume chamber is operated with a closed-loop pressure control scheme, and it is activated by controlling the piston position of a single-acting cylinder driven by a screw motor. Therefore, the variable volume chamber could significantly eliminate the air turbulence disturbance during the air injection stage when compared to an air pump mechanism. Furthermore, the proposed active BP measurement approach is capable of measuring BP characteristics, including systolic blood pressure (SBP and diastolic blood pressure (DBP, during the inflating cycle. Two modes of air injection measurement (AIM and accurate dual-way measurement (ADM were proposed. According to the healthy subject experiment results, AIM reduced 34.21% and ADM reduced 15.78% of the measurement time when compared to a commercial BP monitor. Furthermore, the ADM performed much consistently (i.e., less standard deviation in the measurements when compared to a commercial BP monitor.

  6. Home blood pressure measurement in elderly patients with cognitive impairment: comparison of agreement between relative-measured blood pressure and automated blood pressure measurement.

    Science.gov (United States)

    Plichart, Matthieu; Seux, Marie-Laure; Caillard, Laure; Chaussade, Edouard; Vidal, Jean-Sébastien; Boully, Clémence; Hanon, Olivier

    2013-08-01

    Home blood pressure measurement (HBPM) is recommended by guidelines for hypertension management. However, this method might be difficult to use in elderly individuals with cognitive disorders. Our aim was to assess the agreement and the feasibility of HBPM by a relative as compared with 24-h ambulatory blood pressure monitoring (ABPM) in elderly patients with dementia. Sixty outpatients with dementia aged 75 years and older with office hypertension (≥140/90 mmHg) were subjected successively to HBPM by a trained relative and 24-h ABPM. The order of the two methods was randomized. Current guidelines' thresholds for the diagnosis of hypertension were used. The mean (SD) age of the patients was 80.8 (6.1) years (55% women) and the mean (SD) mini-mental state examination score was 20.1 (6.9). The feasibility of relative-HBPM was very high, with a 97% success rate (defined by ≥12/18 measurements reported). The blood pressure measurements were highly correlated between the two methods (r=0.75 and 0.64 for systolic blood pressure and diastolic blood pressure, respectively; Pmethods for the diagnosis of sustained hypertension and white-coat hypertension was excellent (overall agreement, 92%; κ coefficient, 0.81; 95% CI, 0.61-0.93). Similar results were found for daytime-ABPM. In cognitively impaired elderly patients, HBPM by a relative using an automated device was a good alternative to 24-h ABPM.

  7. Thermopower measurement under high pressure using 'seesaw heating method'

    International Nuclear Information System (INIS)

    Hedo, M; Nakamura, D; Takaesu, Y; Yagasaki, K; Nakama, T; Fujiwara, T; Uchima, K

    2010-01-01

    We have developed a set-up with modified 'seesaw heating method' for the thermopower measurement under pressures P up to 3 GPa at the temperature range between 2 K and 300 K. By using this set-up, the thermopower and electrical resistivity of the single crystalline YbMn 2 Ge 2 under high pressure were measured with enough accuracy. S(T) curve shows the characteristic feature at the magnetic transition in all pressure range, while no evidence of the magnetic phase transition is observed in ρ(T) at P > 1.25 GPa. The measurement results indicate that the simultaneous measurement of the thermopower and electrical resistivity is a useful tool to study the pressure-induced phase transitions.

  8. Radiation Pressure Measurements on Micron-Size Individual Dust Grains

    Science.gov (United States)

    Abbas, M. M.; Craven, P. D.; Spann, J. F.; Witherow, W. K.; West, E. A.; Gallagher, D. L.; Adrian, M. L.; Fishman, G. J.; Tankosic, D.; LeClair, A.

    2003-01-01

    Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2- to 6.82-micron range and irradiating them from above with laser radiation focused to beam widths of approximately 175- 400 microns at ambient pressures particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of SiO2 and the corresponding extinction and scattering efficiencies.

  9. Measurement of the differential pressure of liquid metals

    Science.gov (United States)

    Metz, H.J.

    1975-09-01

    This patent relates to an improved means for measuring the differential pressure between any two points in a process liquid metal coolant loop, wherein the flow of liquid metal in a pipe is opposed by a permanent magnet liquid metal pump until there is almost zero flow shown by a magnetic type flowmeter. The pressure producing the liquid metal flow is inferred from the rate of rotation of the permanent magnet pump. In an alternate embodiment, a differential pressure transducer is coupled to a process pipeline by means of high-temperature bellows or diaphragm seals, and a permanent magnet liquid metal pump in the high-pressure transmission line to the pressure transducer can be utilized either for calibration of the transducer or for determining the process differential pressure as a function of the magnet pump speed. (auth)

  10. Measurement of the differential pressure of liquid metals

    International Nuclear Information System (INIS)

    Metz, H.J.

    1975-01-01

    This patent relates to an improved means for measuring the differential pressure between any two points in a process liquid metal coolant loop, wherein the flow of liquid metal in a pipe is opposed by a permanent magnet liquid metal pump until there is almost zero flow shown by a magnetic type flowmeter. The pressure producing the liquid metal flow is inferred from the rate of rotation of the permanent magnet pump. In an alternate embodiment, a differential pressure transducer is coupled to a process pipeline by means of high-temperature bellows or diaphragm seals, and a permanent magnet liquid metal pump in the high-pressure transmission line to the pressure transducer can be utilized either for calibration of the transducer or for determining the process differential pressure as a function of the magnet pump speed

  11. The urethral smear as a tool in diagnosing adenovirus-induced urethritis.

    Science.gov (United States)

    Tønsberg, E; Hartgill, U

    2014-12-01

    Adenovirus is a recognised cause of non-gonococcal urethritis, and is not uncommonly associated with extragenital signs and symptoms. This case report describes a patient with symptoms of conjunctivitis, meatitis and urethritis. The urethral smear revealed almost exclusively monocytes microscopically, raising the suspicion of a viral aetiology. Results confirmed the presence of adenovirus in both the eyes and urethra. Despite waning reliance on the urethral smear in sexual health clinics, it can still be an important diagnostic tool in assessing the aetiology of non-specific urethritis. Finding an obvious monocytic cell response in the urethral smear can indicate a viral cause and allow the clinician to optimise management, counsel appropriately, and potentially reduce unnecessary antibiotic use. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  12. A rare case of giant urethral calculus and multiple urethral diverticulum

    Directory of Open Access Journals (Sweden)

    A Agarwal

    2012-09-01

    Full Text Available Urethral stones in adults are rare and usually encountered with urethral stricture or diverticulum. We report a 54 years old gentleman who presented with urinary retention due to a large urethral calculus impacted in bulbar urethra with multiple stones in anterior and posterior urethral diverticulum. On examination a mass of size 5.5cmx4cmx3cm was palpable at anterior perineum with a fistulous tract from which pus was oozing out. On retrograde urethrogram a large urethral calculus with bulbar diverticulum and multiple radio opacity in prostatic area were revealed. Patient was managed by suprapubic cystostomy initially and later on by external urethrotomy, diverticulectomy, urethroscopic removal of multiple stones in prostatic urethral diverticulum and urethroplasty. Journal of College of Medical Sciences-Nepal,2012,Vol-8,No-2, 46-48 DOI: http://dx.doi.org/10.3126/jcmsn.v8i2.6838

  13. Obesity and stress urinary incontinence in women: compromised continence mechanism or excess bladder pressure during cough?

    Science.gov (United States)

    Swenson, Carolyn W; Kolenic, Giselle E; Trowbridge, Elisa R; Berger, Mitchell B; Lewicky-Gaupp, Christina; Margulies, Rebecca U; Morgan, Daniel M; Fenner, Dee E; DeLancey, John O

    2017-09-01

    We compared two hypotheses as to why obesity is associated with stress urinary incontinence (SUI): (1) obesity increases demand on the continence system (e.g. higher cough pressure) and (2) obesity compromises urethral function and urethrovaginal support. A secondary analysis was performed using data from a case-control study of SUI in women. Measurements of urethrovaginal support (POP-Q point Aa, urethral axis), urethral function (maximal urethral closure pressure, MUCP), and measures of continence system demand (intravesical pressures at rest and during maximal cough) were analyzed. Cases and controls were divided into three body mass index (BMI) groups: normal (18.5-24.9 kg/m 2 ); overweight (25.0-29.9 kg/m 2 ); and obese (≥30 kg/m 2 ). Logistic regression models where created to investigate variables related to SUI for each BMI group. Structural equation modeling was used to test the direct and indirect relationships among BMI, SUI, maximal cough pressure, MUCP, and POP-Q point Aa. The study included 108 continent controls and 103 women with SUI. MUCP was the factor most strongly associated with SUI in all BMI groups. Maximal cough pressure was significantly associated with SUI in obese women (OR 3.191, 95% CI 1.326, 7.683; p continence mechanism.

  14. High resolution magnetic resonance imaging of urethral anatomy in continent nulliparous pregnant women

    International Nuclear Information System (INIS)

    Preyer, Oliver; Brugger, Peter C.; Laml, Thomas; Hanzal, Engelbert; Prayer, Daniela; Umek, Wolfgang

    2011-01-01

    Introduction: To quantify the distribution of morphologic appearances of urethral anatomy and measure variables of urethral sphincter anatomy in continent, nulliparous, pregnant women by high resolution magnetic resonance imaging (MRI). Materials and methods: We studied fifteen women during their first pregnancy. We defined and quantified bladder neck and urethral morphology on axial and sagittal MR images from healthy, continent women. Results: The mean (±standard deviation) total transverse urethral diameter, anterior–posterior diameter, unilateral striated sphincter muscle thickness, and striated sphincter length were 15 ± 2 mm (range: 12–19 mm), 15 ± 2 mm (range: 11–20 mm), 2 ± 1 mm (range: 1–4 mm), and 13 ± 3 mm (range: 9–18 mm) respectively. The mean (±standard deviation) total urethral length on sagittal scans was 22 ± 3 mm (range: 17.6–26.4 mm). Discussion: Advances in MR technique combined with anatomical and histological findings will provide an insight to understand how changes in urethral anatomy might affect the continence mechanisms in pregnant and non-pregnant, continent or incontinent individuals.

  15. The effect of platelet rich fibrin on growth factor levels in urethral repair.

    Science.gov (United States)

    Soyer, Tutku; Ayva, Şebnem; Boybeyi, Özlem; Aslan, Mustafa Kemal; Çakmak, Murat

    2013-12-01

    Platelet rich fibrin (PRF) is an autologous source of growth factors and promotes wound healing. An experimental study was performed to evaluate the effect of PRF on growth factor levels in urethral repair. Eighteen Wistar albino rats were included in the study. Rats were allocated in three groups (n:6): control (CG), sham (SG), and PRF (PRFG). In SG, a 5 mm vertical incision was performed in the penile urethra and repaired with 10/0 Vicryl® under a microscope. In PRFG, during the urethral repair as described in SG, 1 cc of blood was sampled from each rat and centrifuged for 10 minutes at 2400 rpm. PRF obtained from the centrifugation was placed on the repair site during closure. Penile urethras were sampled 24 hours after PRF application in PRFG and after urethral repair in SG. Transforming growth factor beta receptor (TGF-β-R-CD105), vascular endothelial growth factor (VEGF) and its receptor (VEGF-R), as well as endothelial growth factor receptor (EGFR), were evaluated in subepithelia of the penile skin and urethra. Groups were compared for growth factor levels and growth factor receptor expression with the Kruskal Wallis test. TGF-β-R levels were significantly decreased in SG when compared to CG (p0.05). Use of PRF after urethral repair increases TGF-β-R and VEGF expressions in urethral tissue. PRF can be considered as an alternative measure to improve the success of urethral repair. © 2013.

  16. Pressure and Relative Humidity Measurement Devices for Mars 2020 Rover

    Science.gov (United States)

    Hieta, M.; Genzer, M.; Nikkanen, T.; Haukka, H.; Harri, A.-M.; Polkko, J.; Rodriguez-Manfredi, J. A.

    2017-09-01

    One of the scientific payloads onboard the NASA Mars 2020 rover mission is Mars Environmental Dynamic Analyzer (MEDA): a set of environmental sensors for Mars surface weather measurements. Finnish Meteorological Institute (FMI) provides a pressure measurement device (MEDA PS) and a relative humidity measurement device (MEDA HS) for MEDA.

  17. Blood pressure measurements in the ankle are not equivalent to ...

    African Journals Online (AJOL)

    Background. Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. Objective. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically ...

  18. Urethral syndrome” in women

    Directory of Open Access Journals (Sweden)

    Sławomir Dutkiewicz

    2013-08-01

    Full Text Available A contemporary overview of knowledge is presented on the subject of the so-called urethral syndrome in women, the causes of which have yet to be clearly identified. For practical reasons, the following three forms of the syndrome have been distinguished: interstitial cystitis, the “infectious” form and the “clean” form. In women who do not show symptoms of inflammation of the reproductive organs, bacterial urethritis should be distinguished from the urethral syndrome by evaluating the symptoms, the bacteriological tests and the risk of infection.

  19. TMX-U neutral pressure measurement diagnostic systems

    International Nuclear Information System (INIS)

    Pickles, W.L.; Allen, S.L.; Hill, D.N.; Hunt, A.L.; Simonen, T.C.

    1984-01-01

    The Tandem Mirror Experiment-Upgrade (TMX-U) has a large and complex system of Baird Alpert, magnetron, and Penning gauges, in addition to mass spectrometers (RGA), all of which measure neutral pressures in the many internal regions of TMX-U. These pressure measurements are used as part of the confinement physics data base as well as for management of the TMX-U vacuum system. Dynamic pressures are modeled by a coupled-volumes simulation code, which includes wall reflus, getter pumping, and plasma pumping

  20. A human cadaver fascial compartment pressure measurement model.

    Science.gov (United States)

    Messina, Frank C; Cooper, Dylan; Huffman, Gretchen; Bartkus, Edward; Wilbur, Lee

    2013-10-01

    Fresh human cadavers provide an effective model for procedural training. Currently, there are no realistic models to teach fascial compartment pressure measurement. We created a human cadaver fascial compartment pressure measurement model and studied its feasibility with a pre-post design. Three faculty members, following instructions from a common procedure textbook, used a standard handheld intra-compartment pressure monitor (Stryker(®), Kalamazoo, MI) to measure baseline pressures ("unembalmed") in the anterior, lateral, deep posterior, and superficial posterior compartments of the lower legs of a fresh human cadaver. The right femoral artery was then identified by superficial dissection, cannulated distally towards the lower leg, and connected to a standard embalming machine. After a 5-min infusion, the same three faculty members re-measured pressures ("embalmed") of the same compartments on the cannulated right leg. Unembalmed and embalmed readings for each compartment, and baseline readings for each leg, were compared using a two-sided paired t-test. The mean baseline compartment pressures did not differ between the right and left legs. Using the embalming machine, compartment pressure readings increased significantly over baseline for three of four fascial compartments; all in mm Hg (±SD): anterior from 40 (±9) to 143 (±44) (p = 0.08); lateral from 22 (±2.5) to 160 (±4.3) (p cadaver using a standard embalming machine. Set-up is minimal and the model can be incorporated into teaching curricula. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Use of an Ethanol-Driven Pressure Cell to Measure Hydrostatic Pressure Response of Protein-Stabilized Gold Nanoclusters

    Science.gov (United States)

    2016-01-01

    ARL-TR-7577 ● JAN 2016 US Army Research Laboratory Use of an Ethanol-Driven Pressure Cell to Measure Hydrostatic Pressure ...ARL-TR-7577 ● JAN 2016 US Army Research Laboratory Use of an Ethanol-Driven Pressure Cell to Measure Hydrostatic Pressure Response of...DATES COVERED (From - To) May 2014–September 2014 4. TITLE AND SUBTITLE Use of an Ethanol-Driven Pressure Cell to Measure Hydrostatic Pressure

  2. The protective arm of the renin-angiotensin system may counteract the intense inflammatory process in fetuses with posterior urethral valves.

    Science.gov (United States)

    Rocha, Natalia P; Bastos, Fernando M; Vieira, Érica L M; Prestes, Thiago R R; Silveira, Katia D da; Teixeira, Mauro M; Simões E Silva, Ana Cristina

    2018-03-11

    Posterior urethral valve is the most common lower urinary tract obstruction in male children. A high percentage of patients with posterior urethral valve evolve to end-stage renal disease. Previous studies showed that cytokines, chemokines, and components of the renin-angiotensin system contribute to the renal damage in obstructive uropathies. The authors recently found that urine samples from fetuses with posterior urethral valve have increased levels of inflammatory molecules. The aim of this study was to measure renin-angiotensin system molecules and to investigate their correlation with previously detected inflammatory markers in the same urine samples of fetuses with posterior urethral valve. Urine samples from 24 fetuses with posterior urethral valve were collected and compared to those from 22 healthy male newborns at the same gestational age (controls). Renin-angiotensin system components levels were measured by enzyme-linked immunosorbent assay. Fetuses with posterior urethral valve presented increased urinary levels of angiotensin (Ang) I, Ang-(1-7) and angiotensin-converting enzyme 2 in comparison with controls. ACE levels were significantly reduced and Ang II levels were similar in fetuses with posterior urethral valve in comparison with controls. Increased urinary levels of angiotensin-converting enzyme 2 and of Ang-(1-7) in fetuses with posterior urethral valve could represent a regulatory response to the intense inflammatory process triggered by posterior urethral valve. Copyright © 2018 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  3. Hepatic venous pressure gradients measured by duplex ultrasound

    International Nuclear Information System (INIS)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M.

    2002-01-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P -2 provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  4. Hepatic venous pressure gradients measured by duplex ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M

    2002-08-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P < 0.0001) and with the Child-Pugh score (r = 0.63, P < 0.0001). An acceleration index cut-off value of 1 m.s{sup -2} provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  5. Peripheral vascular effects on auscultatory blood pressure measurement.

    Science.gov (United States)

    Rabbany, S Y; Drzewiecki, G M; Noordergraaf, A

    1993-01-01

    Experiments were conducted to examine the accuracy of the conventional auscultatory method of blood pressure measurement. The influence of the physiologic state of the vascular system in the forearm distal to the site of Korotkoff sound recording and its impact on the precision of the measured blood pressure is discussed. The peripheral resistance in the arm distal to the cuff was changed noninvasively by heating and cooling effects and by induction of reactive hyperemia. All interventions were preceded by an investigation of their effect on central blood pressure to distinguish local effects from changes in central blood pressure. These interventions were sufficiently moderate to make their effect on central blood pressure, recorded in the other arm, statistically insignificant (i.e., changes in systolic [p cooling experiments was statistically significant (p < 0.001). Moreover, both measured systolic (p < 0.004) and diastolic (p < 0.001) pressure decreases during the reactive hyperemia experiments were statistically significant. The findings demonstrate that alteration in vascular state generates perplexing changes in blood pressure, hence confirming experimental observations by earlier investigators as well as predictions by our model studies.

  6. MEASUREMENT OF FRICTIONAL PRESSURE DIFFERENTIALS DURING A VENTILATION SURVEY

    International Nuclear Information System (INIS)

    B.S. Prosser, PE; I.M. Loomis, PE, PhD

    2003-01-01

    During the course of a ventilation survey, both airflow quantity and frictional pressure losses are measured and quantified. The measurement of airflow has been extensively studied as the vast majority of ventilation standards/regulations are tied to airflow quantity or velocity. However, during the conduct of a ventilation survey, measurement of airflow only represents half of the necessary parameters required to directly calculate the airway resistance. The measurement of frictional pressure loss is an often misunderstood and misapplied part of the ventilation survey. This paper compares the two basic methods of frictional pressure drop measurements; the barometer and the gauge and tube. Personal experiences with each method will be detailed along with the authors' opinions regarding the applicability and conditions favoring each method

  7. Dew-point measurements at high water vapour pressure

    Science.gov (United States)

    Lomperski, S.; Dreier, J.

    1996-05-01

    A dew-point meter capable of measuring humidity at high vapour pressure and high temperature has been constructed and tested. Humidity measurements in pure steam were made over the temperature range 100 - 1500957-0233/7/5/003/img1C and a vapour pressure range of 1 - 4 bar. The dew-point meter performance was assessed by comparing measurements with a pressure transmitter and agreement between the two was within 0957-0233/7/5/003/img2% relative humidity. Humidity measurements in steam - air mixtures were also made and the dew-point meter readings were compared to those of a zirconia oxygen sensor. For these tests the dew-point meter readings were generally within 0957-0233/7/5/003/img2% relative humidity of the oxygen sensor measurements.

  8. Dynamic MRI evaluation of urethral hypermobility post-radical prostatectomy.

    Science.gov (United States)

    Suskind, Anne M; DeLancey, John O L; Hussain, Hero K; Montgomery, Jeffrey S; Latini, Jerilyn M; Cameron, Anne P

    2014-03-01

    One postulated cause of post-prostatectomy incontinence is urethral and bladder neck hypermobility. The objective of this study was to determine the magnitude of anatomical differences of urethral and bladder neck position at rest and with valsalva in continent and incontinent men post-prostatectomy based on dynamic MRI. All subjects underwent a dynamic MRI protocol with valsalva and non-valsalva images and a standard urodynamic evaluation. MRI measurements were taken at rest and with valsalva, including (1) bladder neck to sacrococcygeal inferior pubic point line (SCIPP), (2) urethra to pubis, and (3) bulbar urethra to SCIPP. Data were analyzed in SAS using two-tailed t tests. A total of 21 subjects (13 incontinent and 8 continent) had complete data and were included in the final analysis. The two groups had similar demographic characteristics. On MRI, there were no statistically significant differences in anatomic position of the bladder neck or urethra either at rest or with valsalva. The amount of hypermobility ranged from 0.8 to 2 mm in all measures. There were also no differences in the amount of hypermobility (position at rest minus position at valsalva) between groups. We found no statistically significant differences in bladder neck and urethral position or mobility on dynamic MRI evaluation between continent and incontinent men status post-radical prostatectomy. A more complex mechanism for post-prostatectomy incontinence needs to be modeled in order to better understand the continence mechanism in this select group of men. © 2013 Wiley Periodicals, Inc.

  9. Correction of static pressure on a research aircraft in accelerated flight using differential pressure measurements

    Directory of Open Access Journals (Sweden)

    A. R. Rodi

    2012-11-01

    Full Text Available A method is described that estimates the error in the static pressure measurement on an aircraft from differential pressure measurements on the hemispherical surface of a Rosemount model 858AJ air velocity probe mounted on a boom ahead of the aircraft. The theoretical predictions for how the pressure should vary over the surface of the hemisphere, involving an unknown sensitivity parameter, leads to a set of equations that can be solved for the unknowns – angle of attack, angle of sideslip, dynamic pressure and the error in static pressure – if the sensitivity factor can be determined. The sensitivity factor was determined on the University of Wyoming King Air research aircraft by comparisons with the error measured with a carefully designed sonde towed on connecting tubing behind the aircraft – a trailing cone – and the result was shown to have a precision of about ±10 Pa over a wide range of conditions, including various altitudes, power settings, and gear and flap extensions. Under accelerated flight conditions, geometric altitude data from a combined Global Navigation Satellite System (GNSS and inertial measurement unit (IMU system are used to estimate acceleration effects on the error, and the algorithm is shown to predict corrections to a precision of better than ±20 Pa under those conditions. Some limiting factors affecting the precision of static pressure measurement on a research aircraft are discussed.

  10. Urethritis

    Science.gov (United States)

    ... groin area Tender and swollen penis A digital rectal exam will also be performed. Women will have ... Copyright 1997-2018, A.D.A.M., Inc. Duplication for commercial use must be authorized in writing ...

  11. A large extra-abdominal prevesical pseudo-cyst in a newborn with posterior urethral valves.

    NARCIS (Netherlands)

    Binkhorst, M.; Gier, R.P.E. de

    2010-01-01

    A male newborn is described, in whom a large extra-abdominal prevesical pseudo-cyst as well as prune-belly features were present, both of which were supposedly secondary to posterior urethral valves. It is postulated that the subvesical obstruction caused pressure build-up in the urinary tract,

  12. Transperineal Ultrasonographic findings of female urethral diverticulum

    International Nuclear Information System (INIS)

    Cho, Jin Han; Koo, Bong Sik; Nam, Ki Dong; Choi, Jong Cheol; Park, Byeong Ho; Nam, Kyung Jin; Kweon, Heon Young

    1999-01-01

    The purpose of the study was to explore the role of sonography for women with a suspected urethral diverticulum and to evaluate the transperineal ultrasonographic findings of female urethral diverticulum. Eight women (mean age, 44 years) who presented with urethral symptoms and clinically suspected urethral diverticula underwent transperineal ultrasonography; sagittal and coronal images were obtained. Sonography was done with either a 7-5 MHz curved array transducer or 10-5 MHz linear transducer, placed on the perineum at the level of the urethra. Ultrasonograms were assessed for the presence, size, location, shape, echogenicity, and septum. Five patients underwent voiding cystourethrography (VCUG). Results of the sonograms and VCUGs were compared with each other and with surgical findings. Longitudinally, all lesions were located in a middle third of the urethra. In axial plane, 4 diverticula wrapped around 50-100% of the urethra. 3 cases located posteriorly, and 1 case laterally. Seven diverticula contained echogenic debris. Three cases have septa in the diverticulum. The outer margin of the diverticula was smooth in 2 patients and was lobulated in 6 patients. In 3 of 5 cases who underwent VCUG, diverticula were filled with contrast, and appeared to be smaller than those of ultrasonography. In addition, all were single diverticulum in VCUG. Most urethral diverticulum were located in a middle third of the urethra, wrapped around the urethra or round posteriorly. Many cases appear unilocular or multilocular with echogenic debris. Transperineal ultrasonography is easy to operate and accurate for showing urethral diverticulum, and it may be useful for diagnosing this group of women with urethral symptoms and suspected urethral diverticulum. It provides information on the extent and location of the diverticulum, which are important in surgical excision.

  13. Current management of urethral stricture disease

    Directory of Open Access Journals (Sweden)

    Thomas G Smith

    2016-01-01

    Conclusions: Progress is being made toward consistent terminology, and nomenclature which will, in turn, help to standardize treatment within the field of urology. Treatment for urethral stricture and stenosis remains inconsistent between reconstructive and nonreconstructive urologists due to varying treatment algorithms and approaches to disease management. Tissue engineering appears to be future for reconstructive urethral surgery with reports demonstrating feasibility in the use of different tissue substitutes and grafts.

  14. Diagnosis and treatment of urethritis in men.

    Science.gov (United States)

    Brill, John R

    2010-04-01

    Symptoms of urethritis in men typically include urethral discharge, penile itching or tingling, and dysuria. A diagnosis can be made if at least one of the following is present: discharge, a positive result on a leukocyte esterase test in first-void urine, or at least 10 white blood cells per high-power field in urine sediment. The primary pathogens associated with urethritis are Chlamydia trachomatis and Neisseria gonorrhoeae. Racial disparities in the prevalence of sexually transmitted infections persist in the United States, with rates of gonorrhea 40 times higher in black adolescent males than in white adolescent males. Recent studies have focused on identifying causes of nongonococcal urethritis and developing testing for atypical organisms, such as Mycoplasma genitalium and Ureaplasma species. Less common pathogens identified in patients with urethritis include Trichomonas species, adenovirus, and herpes simplex virus. History and examination findings can help distinguish urethritis from other urogenital syndromes, such as epididymitis, orchitis, and prostatitis. The goals of treatment include alleviating symptoms; preventing complications in the patient and his sexual partners; reducing the transmission of coinfections (particularly human immunodeficiency virus); identifying and treating the patient's contacts; and encouraging behavioral changes that will reduce the risk of recurrence. The combination of azithromycin or doxycycline plus ceftriaxone or cefixime is considered first-line empiric therapy in patients with urethritis. Expedited partner treatment, which involves giving patients prescriptions for partners who have not been examined by the physician, is advocated by the Centers for Disease Control and Prevention and has been approved in many states. There is an association between urethritis and an increased human immunodeficiency virus concentration in semen.

  15. Iatrogenic Urethral Defect Repairment: A Case Report

    Directory of Open Access Journals (Sweden)

    Ulas Fidan

    2013-10-01

    Full Text Available    Iatrogenic urethral defect is a complication that occurs after vaginal surgical procedures. Many surgical methods according to place of defect are described in case of injury of urethra. In this article, we reported the repairment of distal urethral defect with the help of greft taken from labia minor. This defect is made by the excision of the granulation tissue that occurred after chronic paraurethral  gland infection.

  16. MRI measurements of intracranial pressure in the upright posture: The effect of the hydrostatic pressure gradient.

    Science.gov (United States)

    Alperin, Noam; Lee, Sang H; Bagci, Ahmet M

    2015-10-01

    To add the hydrostatic component of the cerebrospinal fluid (CSF) pressure to magnetic resonance imaging (MRI)-derived intracranial pressure (ICP) measurements in the upright posture for derivation of pressure value in a central cranial location often used in invasive ICP measurements. Additional analyses were performed using data previously collected from 10 healthy subjects scanned in supine and sitting positions with a 0.5T vertical gap MRI scanner (GE Medical). Pulsatile blood and CSF flows to and from the brain were quantified using cine phase-contrast. Intracranial compliance and pressure were calculated using a previously described method. The vertical distance between the location of the CSF flow measurement and a central cranial location was measured manually in the mid-sagittal T1 -weighted image obtained in the upright posture. The hydrostatic pressure gradient of a CSF column with similar height was then added to the MR-ICP value. After adjustment for the hydrostatic component, the mean ICP value was reduced by 7.6 mmHg. Mean ICP referenced to the central cranial level was -3.4 ± 1.7 mmHg compared to the unadjusted value of +4.3 ± 1.8 mmHg. In the upright posture, the hydrostatic pressure component needs to be added to the MRI-derived ICP values for compatibility with invasive ICP at a central cranial location. © 2015 Wiley Periodicals, Inc.

  17. Foldable micro coils for a transponder system measuring intraocular pressure

    Energy Technology Data Exchange (ETDEWEB)

    Ullerich, S.; Schnakenberg, U. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1; Mokwa, W. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1]|[Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany); Boegel, G. vom [Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany)

    2001-07-01

    A foldable transponder system consisting of a chip and a micro coil for measuring intraocular pressure continuously is presented. The system will be integrated in the haptic of a soft artificial intraocular lens. Calculations of planar micro coils with 6 mm and 10.3 mm in diameter show the limits for planar coils with an outer diameter of 6 mm. For the realisation of the transponder system a 20 {mu}m thick coil with an outer diameter of 10.3 mm, an inner diameter of 7.7 mm, 16 turns and a gap of 20 {mu}m between the windings was selected. Measurements show a good agreement between calculated and measured values. Wireless pressure measurements were carried out showing a linear behaviour of the output signal with respect to the applied pressure. (orig.)

  18. Measurement of rock properties at elevated pressures and temperatures

    International Nuclear Information System (INIS)

    Pincus, H.J.; Hoskins, E.R.

    1985-01-01

    The papers in this volume were presented at an ASTM symposium held on 20 June 1983 in conjunction with the 24th Annual Rock Mechanics Symposium at Texas A and M University, College Station, TX. The purpose of these papers is to present recent developments in the measurement of rock properties at elevated pressures and temperatures, and to examine and interpret the data produced by such measurement. The need for measuring rock properties at elevated pressures and temperatures has become increasingly important in recent years. Location and design of nuclear waste repositories, development of geothermal energy sites, and design and construction of deep excavations for civil, military, and mining engineering require significantly improved capabilities for measuring rock properties under conditions substantially different from those prevailing in most laboratory and in situ work. The development of high-pressure, high-temperature capabilities is also significant for the analysis of tectonic processes

  19. Cost-effectiveness of microscopy of urethral smears for asymptomatic Mycoplasma genitalium urethritis in men in England.

    Science.gov (United States)

    Sutton, Andrew J; Roberts, Tracy E; Jackson, Louise; Saunders, John; White, Peter J; Birger, Ruthie; Estcourt, Claudia

    2018-01-01

    The objective was to determine whether or not the limited use of urethral microscopy to diagnose asymptomatic and symptomatic non-chlamydial, non-gonococcal urethritis (NCNGU) in men is a cost-effective strategy to avert pelvic inflammatory disease (PID), ectopic pregnancy or infertility in female partners. Outputs from a transmission dynamic model of NCNGU in a population of 16-30 year olds in England simulating the number of consultations, PID cases and patients treated over time amongst others, were used along with secondary data to undertake a cost-effectiveness analysis carried out from a health care provider perspective. The main outcome measure was cost per case of PID averted. A secondary outcome measure was cost per major outcome averted, where a major outcome is a case of symptomatic PID, ectopic pregnancy, or infertility. Offering a limited number of asymptomatic men urethral microscopy was more effective than the current practice of no microscopy in terms of reducing the number of cases of PID with an incremental cost-effectiveness ratio of £15,700, meaning that an investment of £15,800 is required to avert one case of PID. For major outcomes averted, offering some asymptomatic men urethral microscopy was again found to be more effective than no microscopy, but here an investment of £49,900 is required to avert one major outcome. Testing asymptomatic men for NCNGU in a small number of genitourinary medicine settings in England is not cost-effective, and thus by maintaining the current practice of not offering this patient group microscopy, this continues to make savings for the health care provider.

  20. Chlamydia trachomatis in non-specific urethritis.

    Science.gov (United States)

    Terho, P

    1978-01-01

    Chlamydia trachomatis was isolated from 58.5% of 159 patients with non-specific urethritis (NSU) using irradiated McCoy cell cultures. Patients with persistent Chlamydia-positive NSU remained Chlamydia-positive each time they were examined before treatment and patients with Chlamydia-negative NSU remained Chlamydia-negative during the course of the illness. Neither the duration of symptoms of urethritis nor a history of previous urethritis affected the chlamydial isolation rate significantly. Of 40 patients with severe discharge 30 (75%) harboured C. trachomatis. One-third of the Chlamydia-positive patients had a severe urethral discharge, while this was present in only 15% of Chlamydia-negative patients. Complications--such as conjunctivitis, arthritis, and epididymitis--were more severe in men with Chlamdia-positive NSU than in those with Chlamydia-negative NSU. Of 64 men matched for sexual promiscuity but without urethritis, none harboured C. trachomatis in his urethra. This differs significantly (P less than 0.001) when compared with patients with NSU. C. trachomatis was isolated from the urogenital tract in 24 (42%) out of 57 female sexual contacts of patients with NSU. The presence of C. trachomatis in the women correlated significantly (P less than 0.001) with the isolation of the agent from their male contacts. These findings give further evidence for the aetiological role of C. trachomatis in non-specific urethritis and its sexual transmission. PMID:678958

  1. Radiological findings of congenital urethral valves

    International Nuclear Information System (INIS)

    Yeon, Kyung Mo; Kook, Shin Ho

    1990-01-01

    Congenital urethral valve is the common cause of hydronephrosis in newborn infants and the most common cause of bladder outlet obstruction in male children. We reviewed and analysed radiological findings and associated anomalies of 16 cases of congenital urethral valve which were examined during the period from January 1985 to December 1989. The most frequent age was under one year old (56%). The main symptoms were urinary dribbing (37.5%), weak stream (25%) and urinary frequency and incontinence (25%). Anterior urethral valve (AUV) was 5 cases (31%) and posterior urethral valve (PUV) was 11 cases(69%), in which 10 cases were Type I and one case was Type III. Bladder wall thickening was seen in all cases and its severity was partly correlated with the degree of vesicoureteral reflux (VUR). VUR was observed in 12 cases (75%), and relatively severe in older age group. The degree of VUR was milder in AUV than PUV. Hydronephrosis was more severe in PUV than in anterior one, and its degree was correlated with the severity of VUR. Associated anomalies were ectopic urethral opening (2 cases), PDA (1 case), congenital megacolon (1 case) and patent urachus (1 case) in PUV. So early diagnosis and treatment of congenital urethral valve is essential to the prevention of renal damage

  2. Urethral prolapse in dogs: a retrospective study.

    Science.gov (United States)

    Carr, Jennifer G; Tobias, Karen M; Smith, Laura

    2014-07-01

    To evaluate the signalment, clinical signs, treatment, and outcome of dogs with urethral prolapse and identify risk factors associated with prolapse or treatment. Retrospective case series. Dogs (n = 48) with urethral prolapse. Medical records (May 1995-June 2010) from 2 referral centers were reviewed. Retrieved data included signalment, clinical signs, laboratory findings, treatment, complications, results of long-term follow-up. Records from Veterinary Medical Data Base (VMDB) were evaluated to determine odds ratios. Odds ratio for urethral prolapse in English bulldogs compared to all breeds was 366.99 (95% CI: 265.83, 506.65). Of 48 affected dogs, 46 had either resection and anastomosis (43 dogs) or urethropexy (3 dogs). The most common early postoperative complication was hemorrhage (39%); postoperative hemorrhage was less common when a simple continuous pattern was used for resection and anastomosis. Prolapse recurred in 57% of dogs available for long-term follow-up; recurrence was less common in dogs that were administered postoperative butorphanol or acepromazine. Gender was not associated with urethral prolapse or postoperative complications. Urethral prolapse occurs most commonly in English bulldogs. Postoperative hemorrhage and prolapse recurrence may be reduced with use of a simple continuous pattern for urethral anastomosis and by administration of postoperative sedation, respectively. Castration status did not appear to affect prolapse development or outcome. © Copyright 2014 by The American College of Veterinary Surgeons.

  3. Standard values of maximum tongue pressure taken using newly developed disposable tongue pressure measurement device.

    Science.gov (United States)

    Utanohara, Yuri; Hayashi, Ryo; Yoshikawa, Mineka; Yoshida, Mitsuyoshi; Tsuga, Kazuhiro; Akagawa, Yasumasa

    2008-09-01

    It is clinically important to evaluate tongue function in terms of rehabilitation of swallowing and eating ability. We have developed a disposable tongue pressure measurement device designed for clinical use. In this study we used this device to determine standard values of maximum tongue pressure in adult Japanese. Eight hundred fifty-three subjects (408 male, 445 female; 20-79 years) were selected for this study. All participants had no history of dysphagia and maintained occlusal contact in the premolar and molar regions with their own teeth. A balloon-type disposable oral probe was used to measure tongue pressure by asking subjects to compress it onto the palate for 7 s with maximum voluntary effort. Values were recorded three times for each subject, and the mean values were defined as maximum tongue pressure. Although maximum tongue pressure was higher for males than for females in the 20-49-year age groups, there was no significant difference between males and females in the 50-79-year age groups. The maximum tongue pressure of the seventies age group was significantly lower than that of the twenties to fifties age groups. It may be concluded that maximum tongue pressures were reduced with primary aging. Males may become weaker with age at a faster rate than females; however, further decreases in strength were in parallel for male and female subjects.

  4. Wavenumber-frequency Spectra of Pressure Fluctuations Measured via Fast Response Pressure Sensitive Paint

    Science.gov (United States)

    Panda, J.; Roozeboom, N. H.; Ross, J. C.

    2016-01-01

    The recent advancement in fast-response Pressure-Sensitive Paint (PSP) allows time-resolved measurements of unsteady pressure fluctuations from a dense grid of spatial points on a wind tunnel model. This capability allows for direct calculations of the wavenumber-frequency (k-?) spectrum of pressure fluctuations. Such data, useful for the vibro-acoustics analysis of aerospace vehicles, are difficult to obtain otherwise. For the present work, time histories of pressure fluctuations on a flat plate subjected to vortex shedding from a rectangular bluff-body were measured using PSP. The light intensity levels in the photographic images were then converted to instantaneous pressure histories by applying calibration constants, which were calculated from a few dynamic pressure sensors placed at selective points on the plate. Fourier transform of the time-histories from a large number of spatial points provided k-? spectra for pressure fluctuations. The data provides first glimpse into the possibility of creating detailed forcing functions for vibro-acoustics analysis of aerospace vehicles, albeit for a limited frequency range.

  5. Temperature measurement in the liquid helium range at pressure

    International Nuclear Information System (INIS)

    Itskevich, E.S.; Krajdenov, V.F.

    1978-01-01

    The use of bronze and germanium resistance thermometers and the use of a (Au + 0.07 % Fe)-Cu thermocouple for temperature measurements from 1.5 to 4.2 K in the hydrostatic compression of up to 10 kbar are considered. To this aim, the thermometer resistance as a function of temperature and pressure is measured. It is revealed that pressure does not change the thermometric response of the bronze resistance thermometer but only shifts it to the region of lower temperatures. The identical investigations of the germanium resistance thermometer shows that strong temperature dependence and the shift of its thermometric response under the influence of pressure make the use of germanium resistance thermometers in high-pressure chambers very inconvenient. The results of the analysis of the (Au + 0.07 % Fe) - Cu thermocouple shows that with a 2 per cent accuracy the thermocouple Seebeck coefficient does not depend on pressure. It permits to use this thermocouple for temperature measurements at high pressures

  6. A Manganin Thin Film Ultra-High Pressure Sensor for Microscale Detonation Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Guodong Zhang

    2018-03-01

    Full Text Available With the development of energetic materials (EMs and microelectromechanical systems (MEMS initiating explosive devices, the measurement of detonation pressure generated by EMs in the microscale has become a pressing need. This paper develops a manganin thin film ultra-high pressure sensor based on MEMS technology for measuring the output pressure from micro-detonator. A reliable coefficient is proposed for designing the sensor’s sensitive element better. The sensor employs sandwich structure: the substrate uses a 0.5 mm thick alumina ceramic, the manganin sensitive element with a size of 0.2 mm × 0.1 mm × 2 μm and copper electrodes of 2 μm thick are sputtered sequentially on the substrate, and a 25 μm thick insulating layer of polyimide is wrapped on the sensitive element. The static test shows that the piezoresistive coefficient of manganin thin film is 0.0125 GPa−1. The dynamic experiment indicates that the detonation pressure of micro-detonator is 12.66 GPa, and the response time of the sensor is 37 ns. In a word, the sensor developed in this study is suitable for measuring ultra-high pressure in microscale and has a shorter response time than that of foil-like manganin gauges. Simultaneously, this study could be beneficial to research on ultra-high-pressure sensors with smaller size.

  7. Dynamic tire pressure sensor for measuring ground vibration.

    Science.gov (United States)

    Wang, Qi; McDaniel, James Gregory; Wang, Ming L

    2012-11-07

    This work presents a convenient and non-contact acoustic sensing approach for measuring ground vibration. This approach, which uses an instantaneous dynamic tire pressure sensor (DTPS), possesses the capability to replace the accelerometer or directional microphone currently being used for inspecting pavement conditions. By measuring dynamic pressure changes inside the tire, ground vibration can be amplified and isolated from environmental noise. In this work, verifications of the DTPS concept of sensing inside the tire have been carried out. In addition, comparisons between a DTPS, ground-mounted accelerometer, and directional microphone are made. A data analysis algorithm has been developed and optimized to reconstruct ground acceleration from DTPS data. Numerical and experimental studies of this DTPS reveal a strong potential for measuring ground vibration caused by a moving vehicle. A calibration of transfer function between dynamic tire pressure change and ground acceleration may be needed for different tire system or for more accurate application.

  8. A Computer Controlled Precision High Pressure Measuring System

    Science.gov (United States)

    Sadana, S.; Yadav, S.; Jha, N.; Gupta, V. K.; Agarwal, R.; Bandyopadhyay, A. K.; Saxena, T. K.

    2011-01-01

    A microcontroller (AT89C51) based electronics has been designed and developed for high precision calibrator based on Digiquartz pressure transducer (DQPT) for the measurement of high hydrostatic pressure up to 275 MPa. The input signal from DQPT is converted into a square wave form and multiplied through frequency multiplier circuit over 10 times to input frequency. This input frequency is multiplied by a factor of ten using phased lock loop. Octal buffer is used to store the calculated frequency, which in turn is fed to microcontroller AT89C51 interfaced with a liquid crystal display for the display of frequency as well as corresponding pressure in user friendly units. The electronics developed is interfaced with a computer using RS232 for automatic data acquisition, computation and storage. The data is acquired by programming in Visual Basic 6.0. This system is interfaced with the PC to make it a computer controlled system. The system is capable of measuring the frequency up to 4 MHz with a resolution of 0.01 Hz and the pressure up to 275 MPa with a resolution of 0.001 MPa within measurement uncertainty of 0.025%. The details on the hardware of the pressure measuring system, associated electronics, software and calibration are discussed in this paper.

  9. Extremely-high vacuum pressure measurement by laser ionization

    International Nuclear Information System (INIS)

    Kokubun, Kiyohide

    1991-01-01

    Laser ionization method has the very high sensitivity for detecting atoms and molecules. Hurst et al. successfully detected a single Cs atom by means of resonance ionization spectroscopy developed by them. Noting this high sensitivity, the authors have attempted to apply the laser ionization method to measure gas pressure, particularly in the range down to extremely high vacuum. At present, hot cathode ionization gauges are used for measuring gas pressure down to ultrahigh vacuum, however, those have a number of disadvantages. The pressure measurement using lasers does not have such disadvantages. The pressure measurement utilizing the laser ionization method is based on the principle that when laser beam is focused through a lens, the amount of atom or molecule ions generated in the focused space region is proportional to gas pressure. In this paper, the experimental results are presented on the nonresonant multiphoton ionization characteristics of various kinds of gases, the ion detection system with high sensitivity and an extremely high vacuum system prepared for the laser ionization experiment. (K.I.)

  10. Noninvasive blood pressure measurement scheme based on optical fiber sensor

    Science.gov (United States)

    Liu, Xianxuan; Yuan, Xueguang; Zhang, Yangan

    2016-10-01

    Optical fiber sensing has many advantages, such as volume small, light quality, low loss, strong in anti-jamming. Since the invention of the optical fiber sensing technology in 1977, optical fiber sensing technology has been applied in the military, national defense, aerospace, industrial, medical and other fields in recent years, and made a great contribution to parameter measurement in the environment under the limited condition .With the rapid development of computer, network system, the intelligent optical fiber sensing technology, the sensor technology, the combination of computer and communication technology , the detection, diagnosis and analysis can be automatically and efficiently completed. In this work, we proposed a noninvasive blood pressure detection and analysis scheme which uses optical fiber sensor. Optical fiber sensing system mainly includes the light source, optical fiber, optical detector, optical modulator, the signal processing module and so on. wavelength optical signals were led into the optical fiber sensor and the signals reflected by the human body surface were detected. By comparing actual testing data with the data got by traditional way to measure the blood pressure we can establish models for predicting the blood pressure and achieve noninvasive blood pressure measurement by using spectrum analysis technology. Blood pressure measurement method based on optical fiber sensing system is faster and more convenient than traditional way, and it can get accurate analysis results in a shorter period of time than before, so it can efficiently reduce the time cost and manpower cost.

  11. Fiber optic pressure sensors in skin-friction measurements

    Science.gov (United States)

    Kidwell, R.

    1985-01-01

    Fiber optic lever pressure sensors intended for use in a low speed wind tunnel environment were designed, constructed and tested for the measurement of normal and shear displacements associated with the pressures acting on a flat aluminum plate. On-site tests performed along with several static and dynamic measurements made have established that, with proper modifications and improvements, the design concepts are acceptable and can be utilized for their intended use. Several elastomers were investigated for use in sensors and for their incorporation into these sensors. Design and assembly techniques for probes and complete sensors were developed.

  12. Indications for portal pressure measurement in chronic liver disease

    DEFF Research Database (Denmark)

    Hobolth, Lise; Bendtsen, Flemming; Møller, Søren

    2012-01-01

    Portal hypertension leads to development of serious complications such as esophageal varices, ascites, renal and cardiovascular dysfunction. The importance of the degree of portal hypertension has been substantiated within recent years. Measurement of the portal pressure is simple and safe...... and the hepatic venous pressure gradient (HVPG) independently predicts survival and development of complications such as ascites, HCC and bleeding from esophageal varices. Moreover, measurements of HVPG can be used to guide pharmacotherapy for primary and secondary prophylaxis for variceal bleeding. Assessment...... of HVPG should therefore be considered as a part of the general characterization of patients with portal hypertension in departments assessing and treating this condition....

  13. Management of severe urethral complications of prostate cancer therapy.

    Science.gov (United States)

    Elliott, Sean P; McAninch, Jack W; Chi, Thomas; Doyle, Sean M; Master, Viraj A

    2006-12-01

    We present our management of urethral stenosis and rectourinary fistula resulting from prostate cancer therapy. We concentrated on cases refractory to minimally invasive treatment, such as dilation, urethrotomy, and urinary and/or fecal diversion. In our prospectively collected urethral reconstruction database we identified patients who underwent reconstruction of urethral stenosis or rectourinary fistula who also received prior treatment for prostate cancer. We documented demographics, prostate cancer pretreatment characteristics, prostate cancer therapy type, urethral reconstruction type and success. A total of 48 patients met the inclusion criteria, including 16 with rectourinary fistula and 32 with urethral stenosis. Urethral complications followed prior radical prostatectomy, brachytherapy, external beam radiotherapy, cryotherapy, thermal ablation and any combination of these procedures. Stenosis repair was successful in 23 of 32 cases (73%) and it differed little between anterior and posterior urethral stenosis. Repair was accomplished by anastomotic urethroplasty in 19 cases, flap urethroplasty in 2, perineal urethrostomy in 2 and a urethral stent in 9. Prior external beam radiotherapy was a risk factor for urethral reconstruction failure. Fistula repair was successful in 14 of 15 patients (93%), excluding 1 who died postoperatively. The complexity of fistula management was dictated by fistula size and the presence or absence of coincident urethral stenosis. Urethral stenosis or rectourethral fistula following prostate cancer therapy can be managed by urethral reconstruction, such that normal voiding via the urethra is maintained, rather than abandoning the urethral outlet and performing heterotopic diversion. This can be accomplished with an acceptable rate of failure, given the complexity of the cases.

  14. Measurement of digital blood pressure after local cooling

    DEFF Research Database (Denmark)

    Nielsen, S L; Lassen, N A

    1977-01-01

    A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between...... the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women...

  15. Measuring element for determining the internal pressure in fuel rods

    International Nuclear Information System (INIS)

    Deckers, H.; Drexler, H.; Reiser, H.

    1983-01-01

    A pressure cell is situated inside the fuel rod, which contains a magnetic core or a core influenced by magnetism, whose position relative to an outer front surface of an end stopper of the fuel rod can vary. The fuel rod contains a pressure cell directly above the lower end stopper or connected to it. This can consist of closed bellows, where if the internal pressure in the fuel rod rises, a ferrite core moves axially. When the pressure drops, this returns to the initial position, which is precisely defined by a stop. To detect a rod defect, the position of the soft iron core relative to the lower edge of the end stopper is scanned by a special measuring device. (orig./HP) [de

  16. Microwave measurements of water vapor partial pressure at high temperatures

    International Nuclear Information System (INIS)

    Latorre, V.R.

    1991-01-01

    One of the desired parameters in the Yucca Mountain Project is the capillary pressure of the rock comprising the repository. This parameter is related to the partial pressure of water vapor in the air when in equilibrium with the rock mass. Although there are a number of devices that will measure the relative humidity (directly related to the water vapor partial pressure), they generally will fail at temperatures on the order of 150C. Since thee author has observed borehole temperatures considerably in excess of this value in G-Tunnel at the Nevada Test Site (NTS), a different scheme is required to obtain the desired partial pressure data at higher temperatures. This chapter presents a microwave technique that has been developed to measure water vapor partial pressure in boreholes at temperatures up to 250C. The heart of the system is a microwave coaxial resonator whose resonant frequency is inversely proportional to the square root of the real part of the complex dielectric constant of the medium (air) filling the resonator. The real part of the dielectric constant of air is approximately equal to the square of the refractive index which, in turn, is proportional to the partial pressure of the water vapor in the air. Thus, a microwave resonant cavity can be used to measure changes in the relative humidity or partial pressure of water vapor in the air. Since this type of device is constructed of metal, it is able to withstand very high temperatures. The actual limitation is the temperature limit of the dielectric material in the cable connecting the resonator to its driving and monitoring equipment-an automatic network analyzer in our case. In the following sections, the theory of operation, design, construction, calibration and installation of the microwave diagnostics system is presented. The results and conclusions are also presented, along with suggestions for future work

  17. A novel approach to office blood pressure measurement: 30-minute office blood pressure vs daytime ambulatory blood pressure

    NARCIS (Netherlands)

    Wel, M.C. van der; Buunk, I.E.; Weel, C. van; Thien, Th.; Bakx, J.C.

    2011-01-01

    PURPOSE: Current office blood pressure measurement (OBPM) is often not executed according to guidelines and cannot prevent the white-coat effect. Serial, automated, oscillometric OBPM has the potential to overcome both these problems. We therefore developed a 30-minute OBPM method that we compared

  18. Experimental viscosity measurements of biodiesels at high pressure

    Directory of Open Access Journals (Sweden)

    Schaschke C.J.

    2016-01-01

    Full Text Available The viscosity of biodiesels of soybean and rapeseed biodiesels blended with mineral diesel fuel were measured at pressures of up to 200 MPa. Using a falling sinker-type viscometer reproducible viscosity data were obtained based on the time taken for a sinker to descend a fixed distance down an enclosed tube under the influence of gravity. Measurements were taken using pressures which correspond to those of interest in automotive common rail diesel engines, and at temperatures of between 25ºC and 80ºC. In all cases, the viscosity of the biodiesel blends were found to increase exponentially for which the blends were noted as being more viscous than pure mineral fuels. A pressure-freezing effect was not observed for the blends.

  19. Exhaust pressure pulsation observation from turbocharger instantaneous speed measurement

    Science.gov (United States)

    Macián, V.; Luján, J. M.; Bermúdez, V.; Guardiola, C.

    2004-06-01

    In internal combustion engines, instantaneous exhaust pressure measurements are difficult to perform in a production environment. The high temperature of the exhaust manifold and its pulsating character make its application to exhaust gas recirculation control algorithms impossible. In this paper an alternative method for estimating the exhaust pressure pulsation is presented. A numerical model is built which enables the exhaust pressure pulses to be predicted from instantaneous turbocharger speed measurements. Although the model is data based, a theoretical description of the process is also provided. This combined approach makes it possible to export the model for different engine operating points. Also, compressor contribution in the turbocharger speed pulsation is discussed extensively. The compressor contribution is initially neglected, and effects of this simplified approach are analysed.

  20. Low temperature measurement of the vapor pressures of planetary molecules

    Science.gov (United States)

    Kraus, George F.

    1989-01-01

    Interpretation of planetary observations and proper modeling of planetary atmospheres are critically upon accurate laboratory data for the chemical and physical properties of the constitutes of the atmospheres. It is important that these data are taken over the appropriate range of parameters such as temperature, pressure, and composition. Availability of accurate, laboratory data for vapor pressures and equilibrium constants of condensed species at low temperatures is essential for photochemical and cloud models of the atmospheres of the outer planets. In the absence of such data, modelers have no choice but to assume values based on an educated guess. In those cases where higher temperature data are available, a standard procedure is to extrapolate these points to the lower temperatures using the Clausius-Clapeyron equation. Last summer the vapor pressures of acetylene (C2H2) hydrogen cyanide (HCN), and cyanoacetylene (HC3N) was measured using two different methods. At the higher temperatures 1 torr and 10 torr capacitance manometers were used. To measure very low pressures, a technique was used which is based on the infrared absorption of thin film (TFIR). This summer the vapor pressure of acetylene was measured the TFIR method. The vapor pressure of hydrogen sulfide (H2S) was measured using capacitance manometers. Results for H2O agree with literature data over the common range of temperature. At the lower temperatures the data lie slightly below the values predicted by extrapolation of the Clausius-Clapeyron equation. Thin film infrared (TFIR) data for acetylene lie significantly below the values predicted by extrapolation. It is hoped to bridge the gap between the low end of the CM data and the upper end of the TFIR data in the future using a new spinning rotor gauge.

  1. Urethral Cancer Treatment (PDQ®)—Patient Version

    Science.gov (United States)

    Urethral cancer occurs in men and women and can spread quickly to lymph nodes near the urethra. Find out about risk factors, symptoms, tests to diagnose, prognosis, staging, and treatment for urethral cancer.

  2. Management of Posterior Urethral Valves in Rural Kenya

    African Journals Online (AJOL)

    Management of Posterior Urethral Valves in Rural. Kenya .... Antwi S. Audit of Posterior Urethral Valve (PUV) in Children at ... Community Paediatrics Committee, Infectious. Diseases ... Effect of Circumcision on Risk of Urinary Tract. Infection in ...

  3. Radiation Pressure Measurements on Micron Size Individual Dust Grains

    Science.gov (United States)

    Abbas, M. M.; Craven, P.D.; Spann, J. F.; Tankosic, D.; Witherow, W. K.; LeClair, A.; West, E.; Sheldon, R.; Gallagher, D. L.; Adrian, M. L.

    2003-01-01

    Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2 micron to 6.82 micron range and irradiating them from above with laser radiation focused to beam-widths of approx. 175-400 micron, at ambient pressures approx. 10(exp -3) to 10(exp -4) torr. The downward displacement of the particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of silica and the corresponding extinction and scattering efficiencies.

  4. Combination of phlebography and sanguinous measurement of venous blood pressure

    International Nuclear Information System (INIS)

    Weber, J.

    1988-01-01

    Phlebographic visualisation offers the highest spatial resolution of all imaging methods both in respect of veins of the leg and pelvis and of the abdomen. Phlebography offers optimal conditions for assessing morphological changes at the veins and in their direct neighbourhood. No quantitative information is available via phlebography if haemodynamics are disturbed; qualitative information is yielded merely to a restricted extent (by assessing flow velocity and collaterals). Direct sanguinous measurement of venous blood pressure is particularly suitable for the quantitative and qualitative assessment of disturbed haemodynamic conditions; in this respect it stands out among the function tests based on the employment of apparatures. If it is combined with phlebography, it is possible not only to optimise the diagnostic yield in the hands of one investigator, but also to reduce the invasiveness of both methods to one single puncture, since the puncture needle is at the same time also an instrument to measure the pressure. The article points out the possibilities and limitations of combining a) ascending phlebography of the leg and pelvis with peripheral venous pressure measurement (phlebodynamometry) and b) visualisation of the veins of the pelvis and vena cava inferior with central sanguinous venous pressure measurement (CP). Indicatious and technical execution are described. (orig.) [de

  5. Measurements and modeling of VLLE at elevated pressures

    DEFF Research Database (Denmark)

    Laursen, Torben

    and pure component calibration. Samples from the different liquid phases in the high-pressure cell is taken using a moveable needle. The systems investigated have been a combination of the components: CO2, N2, di-methyl ether (DME), water, methanol, ethanol and 1-propanol. 41 isotherms have been measured...

  6. Deformation measurement of a pressure vessel flange by holographic interferometry

    International Nuclear Information System (INIS)

    Goncalves Junior, Armando A.; Schneider, C.A.

    1984-01-01

    An automatic metodology used for the measurement of displacement through the holographic interferometry is presented. In order to shown its performance and potentiality, the displacement field from a pipe's and flange, when submited to an internal pressure, is experimentally found. Holography's results are compared with other technique's results. (Author) [pt

  7. When and how should we measure intra- abdominal pressure?

    African Journals Online (AJOL)

    2008-11-11

    Nov 11, 2008 ... developing intra-abdominal hypertension (IAH) and. ACS. This may be ... the development of systemic inflammatory response syndrome (SIRS) ... of this technique are that it places the patient at increased risk for .... 9. Malbrain ML. Different techniques to measure intra-abdominal pressure (IAP): time for a.

  8. Measuring occupational stress: development of the pressure management indicator.

    Science.gov (United States)

    Williams, S; Cooper, C L

    1998-10-01

    The study of occupational stress is hindered by the lack of compact and comprehensive standardized measurement tools. The Pressure Management Indicator (PMI) is a 120-item self-report questionnaire developed from the Occupational Stress Indicator (OSI). The PMI is more reliable, more comprehensive, and shorter than the OSI. It provides an integrated measure of the major dimensions of occupational stress. The outcome scales measure job satisfaction, organizational satisfaction, organizational security, organizational commitment, anxiety--depression, resilience, worry, physical symptoms, and exhaustion. The stressor scales cover pressure from workload, relationships, career development, managerial responsibility, personal responsibility, home demands, and daily hassles. The moderator variables measure drive, impatience, control, decision latitude, and the coping strategies of problem focus, life work balance, and social support.

  9. A study of dynamic foot pressure measurement in diabetic patients

    Directory of Open Access Journals (Sweden)

    Milka D Madhale

    2017-01-01

    Full Text Available Introduction: Diabetic foot ulcer is a major source of morbidity and a leading cause of hospitalization. It is estimated that approximately 20% of hospital admissions among patients with diabetes mellitus are due to diabetic foot ulcer. It can lead to infection, gangrene, amputation, and even death if appropriate care is not provided. Overall, the lower limb amputation in diabetic patients is 15 times higher than in non-diabetics. In the majority of cases, the cause for the foot ulcer is the altered architecture of the foot due to neuropathy resulting in abnormal pressure points on the soles. Purpose: The aim of this study is to develop low cost, lightweight foot pressure scanner and check its reliability and validity which can help to prevent foot ulceration. Design/Methodology/Approach: In the present study, a low cost, lightweight foot pressure scanner is developed, and dynamic plantar pressures in a group of 110 Indian patients with diabetes with or without neuropathy and foot ulcers are measured. Practical Implications: If these pressure points can be detected, ulcers can be prevented by providing offloading footwear. Originality/Value: Differences are found in dynamic foot pressures in different study groups, namely, diabetic patients, patients with diabetic peripheral neuropathy, patients with foot ulcers, and nondiabetics. The differences are significant (P < 0.01, which showed the validity of the tool. Reliability and consistency of the tool was checked by test–retest method. Paper Type: Original Research work. Conclusion: Based on the results of the present study, it is concluded that the scanner is successfully developed and it can measure foot pressures. It is a novel device to proactively monitor foot health in diabetics in an effort to prevent and reduce diabetic foot complications.

  10. Fiber optic pressure sensors in skin-friction measurements

    Science.gov (United States)

    Cuomo, F. W.

    1986-01-01

    A fiber optic lever sensing technique that can be used to measure normal pressure as well as shear stresses is discussed. This method uses three unequal fibers combining small size and good sensitivity. Static measurements appear to confirm the theoretical models predicted by geometrical optics and dynamic tests performed at frequencies up to 10 kHz indicate a flat response within this frequency range. These sensors are intended for use in a low speed wind tunnel environment.

  11. Localized urethral cancer in women

    International Nuclear Information System (INIS)

    Mayer, R.; Fowler, J.E. Jr.; Clayton, M.

    1987-01-01

    The results of treatments for localized carcinoma of the urethra were assessed in 21 consecutive women treated at our institutions over a twenty year period. Only one of the tumors was confined to the distal urethra. Eighty-six percent invaded the periurethral tissues and 24% were known to be associated with regional lymph node metastases. Fifty-seven percent were adenocarcinomas. Five patients refused active therapeutic intervention and expired within one to 30 months following diagnosis. Sixteen patients were treated with extirpative surgery, radiation therapy, or combinations of the two. Four are free of disease at one, four, eleven, and 15 years after treatment. Nine developed pelvic recurrences, two developed pelvic recurrences and distant metastases and one developed distant metastases only from six to 72 months (mean, 19 months) after initial treatment. Eight of these 12 patients died at two to 13 months (mean, 8 months) after secondary treatment, two are alive with residual pelvic tumor, and two are clinically free of disease at 7 and 48 months. Only six patients were known to have distant metastases at the time of death and five of these six had adenocarcinomas. Advanced localized urethral cancer in women is difficult to eradicate and usually fatal

  12. Minimally invasive surgical approach to treat posterior urethral diverticulum

    Directory of Open Access Journals (Sweden)

    Ossamah Alsowayan

    2015-01-01

    Full Text Available Urethral diverticulum is a localized saccular or fusiform out-pouching of the urethra. It may occur at any point along the urethra in both male and females. Male urethral diverticulum is rare, and could be either congenital or acquired, anterior or posterior. The mainstay treatment of posterior urethral diverticulum (PUD is the open surgical approach. Here we discuss our minimally invasive surgical approach (MIS in managing posterior urethral diverticulum.

  13. Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences

    NARCIS (Netherlands)

    van der Hoeven, Niels V.; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A.; van den Born, Bert-Jan H.

    2013-01-01

    There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age ( <50 or ≥60 years) and

  14. Fundamentals and clinical perspective of urethral sphincter instability as a contributing factor in patients with lower urinary tract dysfunction--ICI-RS 2014.

    Science.gov (United States)

    Kirschner-Hermanns, Ruth; Anding, Ralf; Rosier, Peter; Birder, Lori; Andersson, Karl Erik; Djurhuus, Jens Christian

    2016-02-01

    Urethral pathophysiology is often neglected in discussions of bladder dysfunction. It has been debated whether "urethral sphincter instability," referred to based on observed "urethral pressure variations," is an important aspect of overactive bladder syndrome (OAB). The purpose of this report is to summarize current urethral pathophysiology evidence and outline directions for future research based on a literature review and discussions during the ICI-RS meeting in Bristol in 2014. Urethral pathophysiology with a focus on urethral pressure variation (UPV) was presented and discussed in a multidisciplinary think tank session at the ICI_R meeting in Bristol 2014. This think tank session was based on collaboration between physicians and basic science researchers. Experimental animal studies or studies performed in clinical series (predominantly symptomatic women) provided insights into UPV, but the findings were inconsistent and incomplete. However, UPV is certainly associated with lower urinary tract symptoms (likely OAB), and thus, future research on this topic is relevant. Future research based on adequately defined clinical (and urodynamic) parameters with precisely defined patient groups might shed better light on the cause of OAB symptoms. Further fundamental investigation of urethral epithelial-neural interactions via the release of mediators should enhance our knowledge and improve the management of patients with OAB. © 2016 The Authors. Neurourology and Urodynamics published by Wiley Periodicals, Inc.

  15. Male urethral strictures and their management

    Science.gov (United States)

    Hampson, Lindsay A.; McAninch, Jack W.; Breyer, Benjamin N.

    2014-01-01

    Male urethral stricture disease is prevalent and has a substantial impact on quality of life and health-care costs. Management of urethral strictures is complex and depends on the characteristics of the stricture. Data show that there is no difference between urethral dilation and internal urethrotomy in terms of long-term outcomes; success rates range widely from 8–80%, with long-term success rates of 20–30%. For both of these procedures, the risk of recurrence is greater for men with longer strictures, penile urethral strictures, multiple strictures, presence of infection, or history of prior procedures. Analysis has shown that repeated use of urethrotomy is not clinically effective or cost-effective in these patients. Long-term success rates are higher for surgical reconstruction with urethroplasty, with most studies showing success rates of 85–90%. Many techniques have been utilized for urethroplasty, depending on the location, length, and character of the stricture. Successful management of urethral strictures requires detailed knowledge of anatomy, pathophysiology, proper patient selection, and reconstructive techniques. PMID:24346008

  16. Management of posterior urethral disruption injuries.

    Science.gov (United States)

    Myers, Jeremy B; McAninch, Jack W

    2009-03-01

    Posterior urethral disruption is a traumatic injury to the male urethra, which most often results from pelvic fracture. After trauma, the distraction defect between the two ends of the urethra often scars and becomes fibrotic, blocking the urethra and bladder emptying. Increasing evidence suggests that many posterior urethral disruptions occur at the junction between the membranous urethra and the bulbar urethra, which is distal to the rhabdosphincter. In the acute setting, when a posterior urethral disruption is suspected, retrograde urethrography should be performed. Posterior urethral disruptions can be managed acutely by realignment of the urethra over a urethral catheter or by placement of a suprapubic catheter for bladder drainage only. Once fibrosis has stabilized, the patient can undergo posterior urethroplasty. In most cases, this procedure can be performed via a perineal approach in a single-stage surgery. The results of this single-stage perineal urethroplasty are excellent, and a patent urethra can be re-established in the majority of men who undergo surgery.

  17. Acoustic emission measurements at the pressure vessel ZB2

    International Nuclear Information System (INIS)

    Tirbonod, B.; Hanacek, L.

    1990-01-01

    The work presented here is the Swiss contribution to the project 'Zwischenbehaelter 2 (ZB2)' hosted by the 'Bundesministerium fuer Forschung und Technologie' of the Federal Republic of Germany. One of the crack-like defects introduced at the inside surface of the thick-walled pressure vessel ZB2 was locally monitored by acoustic emission. The measurement system was broadband (0.5 - 5 MHz) and allowed a threedimensional location of the source. The vessel was subjected to different tests. Signals were recorded during the second series of hydrotests, fast pressure cycles and fatigue test at 50 C. About 1 signal per hydrotest or cycle was recorded. For the hydrotests the signals were recorded generally at loading in the intermediate range of pressure; the sources were located in the artificial defect. Recurrent and non recurrent signals were recorded during the fatigue test. At loading, signals were captured up to the maximum pressure and for the recurrent signals at well defined pressure ranges. All the sources (except one, located in the base material ahead of the artificial defect) were situated in the artificial defect. The pressure and location depended on the loading phase and on the cycle range. The measurements were discussed by describing the signals by measurement, signal and source parameters. The goal was to identify the source mechanism and to assess the growth of the defect. For the hydrotests the identification of the mechanism at loading remains open. For the fatigue test the source situated in the base material was attributed to a primary mechanism; this source could assess the growth of the defect on the basis of linear elastic fracture mechanics. A secondary mechanism was suggested for recurrent sources active at loading. For all the tests, the sources active at unloading were attributed to a secondary mechanism. (author)

  18. Peripheral blood T cell proliferative response to chlamydial organisms in gonococcal and non-gonococcal urethritis and presumed pelvic inflammatory disease

    Science.gov (United States)

    Shahmanesh, M.; Brunst, M.; Sukthankar, A.; Pearce, J. H.; Gaston, J. S.

    1999-01-01

    OBJECTIVE: To study peripheral blood mononuclear cell (PBMC) proliferative response to Chlamydia trachomatis elementary bodies in (a) controls, (b) various stages of gonococcal (c) and non-gonococcal urethritis, and (d) women with a clinical diagnosis of pelvic inflammatory disease (PID). METHODS: We categorised 102 men presenting to a GUM clinic with urethritis by organisms (C trachomatis (CT) or Neisseria gonorrhoeae (NG) (both by culture), and whether it was their first (urethritis naive) or subsequent (urethritis experienced) attack. 23 women presenting to the clinic with a clinical diagnosis of PID were also investigated. We measured PBMC proliferative responses to C trachomatis (DK20--an oculogenital strain, serovar E), lysate of McCoy cells (used to propagate chlamydiae), and the recall antigen PPD. Controls were 37 men and women without present or past history of urethritis or chlamydial infection. Results were expressed as the ratio of the stimulation index (SI) obtained with DK20 compared with McCoy cells (DK index), and the ratio of the SI obtained with DK20 compared with PPD (PPD index). RESULTS: The median SI to DK20 in the urethritis was 12.7 which was significantly higher than the controls (7.6, p urethritis patients (17.4) and the controls (22.4). All urethritis patient subgroups had a significantly higher DK index and PPD index than the controls. There was no difference in the PPD and DK index between urethritis naive and urethritis experienced patients and between the culture positive and culture negative urethritis subgroups. In PID patients only the PPD index was significantly higher than the controls. CONCLUSION: Men presenting with urethritis and women presenting with PID both have significantly greater peripheral blood mononuclear cell proliferative responses to the DK20 strain of C trachomatis than controls. A similar T cell proliferative response pattern in urethritis naive patients with either gonococcal or non-gonococcal urethritis could

  19. Piston cylinder cell for high pressure ultrasonic pulse echo measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kepa, M. W., E-mail: mkepa@staffmail.ed.ac.uk; Huxley, A. D. [SUPA, Centre for Science at Extreme Conditions and School of Physics and Astronomy, University of Edinburgh, Edinburgh EH9 3JZ (United Kingdom); Ridley, C. J.; Kamenev, K. V. [Centre for Science at Extreme Conditions and School of Engineering, University of Edinburgh, Edinburgh EH9 3FD (United Kingdom)

    2016-08-15

    Ultrasonic techniques such as pulse echo, vibrating reed, or resonant ultrasound spectroscopy are powerful probes not only for studying elasticity but also for investigating electronic and magnetic properties. Here, we report on the design of a high pressure ultrasonic pulse echo apparatus, based on a piston cylinder cell, with a simplified electronic setup that operates with a single coaxial cable and requires sample lengths of mm only. The design allows simultaneous measurements of ultrasonic velocities and attenuation coefficients up to a pressure of 1.5 GPa. We illustrate the performance of the cell by probing the phase diagram of a single crystal of the ferromagnetic superconductor UGe{sub 2}.

  20. Seat pressure measurement technologies: considerations for their evaluation.

    Science.gov (United States)

    Gyi, D E; Porter, J M; Robertson, N K

    1998-04-01

    Interface pressure measurement has generated interest in the automotive industry as a technique which could be used in the prediction of driver discomfort for various car seat designs, and provide designers and manufacturers with rapid information early on in the design process. It is therefore essential that the data obtained are of the highest quality, relevant and have some quantitative meaning. Exploratory experimental work carried out with the commercially available Talley Pressure Monitor is outlined. This led to a better understanding of the strengths and weaknesses of this system and the re-design of the sensor matrix. Such evaluation, in the context of the actual experimental environment, is considered essential.

  1. Long-term effect of urethral dilatation and internal urethrotomy for urethral strictures.

    Science.gov (United States)

    Veeratterapillay, Rajan; Pickard, Rob S

    2012-11-01

    Urethral dilatation and direct visual internal urethrotomy (DVIU) are widely used minimally invasive options to manage men with urethral strictures. Advances in open urethroplasty with better long-term cure rates have fuelled the continuing debate as to which treatment is best for primary and recurrent urethral strictures. We reviewed recent literature to identify contemporary practice of urethral dilatation and DVIU and the long-term outcome of these procedures. Systematic literature search for the period January 2010 to December 2011 showed that urethral dilatation and DVIU remain frequently used treatment options as confirmed by surveys of urologists in the USA and the Netherlands. Multiple reports of laser DVIU confirm the safety of this approach but long-term data were lacking. Stricture free rates from urethra dilatation and DVIU vary from 10 to 90% at 12 months, although adjunctive intermittent self-dilatation can reduce time to recurrence. Although quality-of-life benefit appears good in the short term, repeated procedures may harm sexual function in the long-term. Urethral dilatation and DVIU remain widely used in urethral stricture management but high-level comparative evidence of benefit and harms against urethroplasty in the short and long-term is still lacking.

  2. Use of an Absorbable Urethral Stent for the Management of a Urethral Stricture in a Stallion.

    Science.gov (United States)

    Trela, Jan M; Dechant, Julie E; Culp, William T; Whitcomb, Mary B; Palm, Carrie A; Nieto, Jorge E

    2016-11-01

    To describe the successful management of a urethral stricture with an absorbable stent in a stallion. Clinical report. Stallion with a urethral stricture. A 12-year-old Thoroughbred breeding stallion was evaluated for acute onset of colic. Uroperitoneum because of presumptive urinary bladder rupture, with urethral obstruction by a urethrolith, was diagnosed. The uroperitoneum was treated conservatively. The urethrolith was removed through a perineal urethrotomy. Approximately 15 weeks after urethrolith removal, the stallion presented with a urethral stricture. The stricture was unsuccessfully treated with an indwelling urinary catheter and 4 attempts at balloon dilation. Eight weeks after diagnosis of stricture, an absorbable polydioxanone (20 mm × 80 mm) urethral stent was implanted under percutaneous, ultrasound guidance. Urethroscopy was performed at 70, 155, and 230 days after stent placement and the endoscope passed through the affected site without complication. Urethroscopy at 155 days showed the stent had been reabsorbed. Follow-up 20 months after stent placement reports the stallion was able to void a normal urine stream. Absorbable urethral stent placement was a feasible treatment for urethral stricture in this stallion. © Copyright 2016 by The American College of Veterinary Surgeons.

  3. Editorial comment on “Etiology of male urethral strictures ...

    African Journals Online (AJOL)

    My colleagues and I are strongly convinced that urethral stricture disease presents different etiologies and pathological characteris- tics in developed compared to developing countries [1]. Recently, we reported the differences in posterior urethral stricture after pelvic fracture urethral distraction defects in developing (India) ...

  4. 21 CFR 876.4590 - Interlocking urethral sound.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Interlocking urethral sound. 876.4590 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4590 Interlocking urethral sound. (a) Identification. An interlocking urethral sound is a device that consists of two metal sounds...

  5. Urethral catheterization:The need for adequate undergraduate ...

    African Journals Online (AJOL)

    E.V. Ezenwa

    2016-12-26

    Dec 26, 2016 ... urethral catheterization procedure and precautionary methods taken while carrying out the procedure. Also assessed was the ... Conclusion: Newly recruited interns have poor practical exposure to urethral catheterization. Efforts should .... ska B. Treatment of posterior and anterior urethral trauma. BJU Int.

  6. [Parkinson gait analysis using in-shoe plantar pressure measurements].

    Science.gov (United States)

    Pihet, D; Moretto, P; Defebvre, L; Thevenon, A

    2006-02-01

    The literature reports some studies describing the walking pattern of patients with Parkinson's disease, its deterioration with disease severity and the effects of various treatments. Other studies concerned the plantar pressure distribution when walking. The aim of this study was to validate the use of baropodometric measurements for gait analysis of parkinsonian patients at various stages of disease severity and in on and off phases. Fifteen normal control subjects and fifteen parkinsonian patients equipped with a plantar pressure measurement system performed walking tests. The parkinsonian patients performed the walking tests in off phase then in on phase. A clinical examination was performed to score the motor handicap on the UPDRS scale. Analysis of the plantar pressures of the parkinsonian subjects under various footprint areas detected significant baropodometric differences compared with controls, between groups with different UPDRS scores, and before and after L-Dopa treatment. Plantar pressures measurements allow a sufficiently fine discrimination for using it to detect parkinsonism and monitor patients with Parkinson's disease.

  7. Measurement of pressure on a surface using bubble acoustic resonances

    International Nuclear Information System (INIS)

    Aldham, Ben; Manasseh, Richard; Liffman, Kurt; Šutalo, Ilija D; Illesinghe, Suhith; Ooi, Andrew

    2010-01-01

    The frequency response of gas bubbles as a function of liquid ambient pressure was measured and compared with theory. A bubble size with equivalent spherical radius of 2.29 mm was used over a frequency range of 1000–1500 Hz. The ultimate aim is to develop an acoustic sensor that can measure static pressure and is sensitive to variations as small as a few kPa. The classical bubble resonance frequency is known to vary with ambient pressure. Experiments were conducted with a driven bubble in a pressurizable tank with a signal processing system designed to extract the resonant peak. Since the background response of the containing tank is significant, particularly near tank-modal resonances, it must be carefully removed from the bubble response signal. A dual-hydrophone method was developed to allow rapid and reliable real-time measurements. The expected pressure dependence was found. In order to obtain a reasonable match with theory, the classical theory was modified by the introduction of a 'mirror bubble' to account for the influence of a nearby surface. (technical design note)

  8. The detection of microorganisms related to urethritis from the oral cavity of male patients with urethritis.

    Science.gov (United States)

    Le, Phuong Thi; Hamasuna, Ryoichi; Matsumoto, Masahiro; Furubayashi, Keiichi; Hatanaka, Masayuki; Kawai, Shuichi; Yamaguchi, Takamasa; Uehara, Kazutaka; Murakami, Norihiko; Yoshioka, Masaru; Nakayama, Ken; Shiono, Yutaka; Muraoka, Keisuke; Suzuki, Masahiko; Fujimoto, Naohiro; Matsumoto, Tetsuro

    2017-10-01

    To investigate the presence of microorganisms related to urethritis in the oral cavity of male patients with urethritis and the efficacies of antimicrobials for urethritis on microorganisms in the oral cavity. Ninety-two male patients with urethritis and 17 male controls participated to this study at 12 urology clinics in Japan between March 2014 and March 2015. The first voided urine (FVU) and oral wash fluid (OWF) specimens were collected from the participants. The microorganisms in both FVU and OWF specimens were detected by nucleic acid amplification tests at the first and follow-up visit. The efficacies of antimicrobials were evaluated after 1-4 weeks treatment completion. In a total of 92 male patients with urethritis, Neisseria gonorrhoeae, Chlamydia trachomatis, Mycoplasma hominis, Mycoplasma genitalium, Ureaplasma urealyticum, Ureaplasma parvum, Trichomonas vaginalis and Gardnerella vaginalis were detected from OWF specimens of 12%, 3%, 9%, 0%, 12%, 3%, 3% and 15% patients, respectively. From control males, no microorganism was detected from OWF specimens. Among 46 patients who could be evaluated for antimicrobial efficacies at the follow-up visit, 5 in FVU specimens failed by azithromycin (AZM), and 10 failed in OWF specimens (7 by AZM, 2 by tetracycline, 1 by spectinomycin; p = 0.002). Especially, a high prevalence of G. vaginalis remained positive after treatment for urethritis in the oral cavity. Microorganisms related to urethritis were detected in the oral cavity of male patients with urethritis. Antimicrobials that focused on urethritis, especially AZM regimen seem to be less effective for microorganisms in the oral cavity. Copyright © 2017 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  9. Early Primary Endoscopic Realignment of Posterior Urethral Injury- Evaluation and Follow-Up

    Directory of Open Access Journals (Sweden)

    Prasad Mylarappa

    2013-07-01

    Full Text Available Background: The management of complete orpartial posterior urethral disruption is contro-versial and much debate continues regarding theimmediate, early and delayed definitive therapy.Objective: We report our institutional experi-ence and long term result of early endoscopicrealignment of traumatic posterior urethral in-jury. Method and Materials: Between Septem-ber 1996 and March 2012, ninety six men witheither complete (84 or partial (12 posteriorurethral injury secondary to blunt trauma (11or pelvic fractures (85, presented to our insti-tution and these patients underwent immediatesuprapubic cystostomy followed by early pri-mary endoscopic realignment done 3-8 daysafter injury. Result: Seventy four patients(92.5% were continent after catheter removal.Urethral stricture was seen in seventy two pa-tients (90% of which fifty patients (69.4%had simple urethral stricture who were managedby urethral dilatation on outpatient basis. Four-teen patients (19.4% developed short stric-tures which were successfully treated with vi-sual internal urethrotomy. Eight patients(11.1% required anastomotic urethroplasty fordense stricture. Potency was retained in sev-enty five patients (93.75%. Urinary flow mea-surements at follow-up evaluation were satis-factory.Conclusion:Early primary endoscopic realign-ment in our experience reduces time to spon-taneous voiding, decrease the need for majorreconstructive surgery and long term supra pub-lic urinary diversion.

  10. Pressure pulsation measurements in pipe and cluster flows

    International Nuclear Information System (INIS)

    Benemann, A.; Voj, P.

    1976-01-01

    Measuring and evaluation techniques of pressure pulsations in pipe and cluster flows are described. The measurements were made on a 1 m long SNR rod-cluster and its feed and drain pipes. At Reynolds numbers in the cluster of 8.9 x 10 4 flow velocities of 14 m/sec were achieved. With the aid of a block diagram recording of the measured values by piezoelectric crystal and piezo-resistive strain gange as well as data processing are explained. For the analytical treatment of the pressure pulsation signals characterizing the turbulence field computer codes of a digital computer and a fast-fourier analyzer (Hewlett-Packard 5450 A) were used. The results show good agreement with theoretical curves on the behaviour of turbulent boundary layers of cluster and pipe flows at high Reynolds numbers. (TK) [de

  11. Pressure drop ana velocity measurements in KMRR fuel rod bundles

    International Nuclear Information System (INIS)

    Yagn, Sun Kyu; Chung, Heung June; Chung, Chang Whan; Chun, Se Young; Song, Chul Wha; Won, Soon Yeun; Chung, Moon Ki

    1990-01-01

    The detailed hydraulic characteristic measurements in subchannels of longitudinally finned rod bundles using one-component LDV(Laser Doppler Velocimeter) were performed. Time mean axial velocity, turbulent intensity, and turbulent micro scales, such as time auto-correlation, Eulerian integral and micro scale, Kolmogorov length and time scale, and Taylor micro length scale were measured. The signals from LDV are inherently more or less discontinuous. The spectra of signals having such intermittent defects can be obtained by the fast Fourier transformation (FFT) of the auto-correlation function. The turbulent crossflow mixing rate between neighboring subchannels and dominant frequencies were evaluated from the measured data. Pressure drop data were obtained for the typical 36-element and 18-element fuel rod bundles fabricated by the design requirement of KMRR fuel and for other type of fuels assembled with 6-fin rods to investigate the fin effects on the pressure drop characteristics

  12. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.

    Science.gov (United States)

    Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio

    2004-06-01

    It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (pforearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (pforearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.

  13. Body mass index and blood pressure measurement during pregnancy.

    LENUS (Irish Health Repository)

    Hogan, Jennifer L

    2012-02-01

    OBJECTIVE: The accurate measurement of blood pressure requires the use of a large cuff in subjects with a high mid-arm circumference (MAC). This prospective study examined the need for a large cuff during pregnancy and its correlation with maternal obesity. METHODS: Maternal body mass index (BMI), fat mass, and MAC were measured. RESULTS: Of 179 women studied, 15.6% were obese. With a BMI of level 1 obesity, 44% needed a large cuff and with a BMI of level 2 obesity 100% needed a large cuff. CONCLUSION: All women booking for antenatal care should have their MAC measured to avoid the overdiagnosis of pregnancy hypertension.

  14. Measurements of acoustic pressure at high amplitudes and intensities

    International Nuclear Information System (INIS)

    Crum, L A; Bailey, M R; Kaczkowski, P; McAteer, J A; Pishchalnikov, Y A; Sapozhnikov, O A

    2004-01-01

    In our research group, we desire measurements of the large pressure amplitudes generated by the shock waves used in shock wave lithotripsy (SWL) and the large acoustic intensities used in High Intensity Focused Ultrasound (HIFU). Conventional piezoelectric or PVDF hydrophones can not be used for such measurements as they are damaged either by cavitation, in SWL applications, or heat, in HIFU applications. In order to circumvent these difficulties, we have utilized optical fiber hydrophones in SWL that do not cavitate, and small glass probes and a scattering technique for measurements of large HIFU intensities. Descriptions of these techniques will be given as well as some typical data

  15. Measurement of carotid bifurcation pressure gradients using the Bernoulli principle.

    Science.gov (United States)

    Illig, K A; Ouriel, K; DeWeese, J A; Holen, J; Green, R M

    1996-04-01

    Current randomized prospective studies suggest that the degree of carotid stenosis is a critical element in deciding whether surgical or medical treatment is appropriate. Of potential interest is the actual pressure drop caused by the blockage, but no direct non-invasive means of quantifying the hemodynamic consequences of carotid artery stenoses currently exists. The present prospective study examined whether preoperative pulsed-Doppler duplex ultrasonographic velocity (v) measurements could be used to predict pressure gradients (delta P) caused by carotid artery stenoses, and whether such measurements could be used to predict angiographic percent diameter reduction. Preoperative Doppler velocity and intraoperative direct pressure measurements were obtained, and per cent diameter angiographic stenosis measured in 76 consecutive patients who underwent 77 elective carotid endarterectomies. Using the Bernoulli principle (delta P = 4v(2), pressure gradients across the stenoses were calculated. The predicted delta P, as well as absolute velocities and internal carotid artery/common carotid velocity ratios were compared with the actual delta P measured intraoperatively and with preoperative angiography and oculopneumoplethysmography (OPG) results. An end-diastolic velocity of > or = 1 m/s and an end-diastolic internal carotid artery/common carotid artery velocity ratio of > or = 10 predicted a 50% diameter angiographic stenosis with 100% specificity. Although statistical significance was reached, preoperative pressure gradients derived from the Bernoulli equation could not predict actual individual intraoperative pressure gradients with enough accuracy to allow decision making on an individual basis. Velocity measurements were as specific and more sensitive than OPG results. Delta P as predicted by the Bernoulli equation is not sufficiently accurate at the carotid bifurcation to be useful for clinical decision making on an individual basis. However, end

  16. Ventral inlay buccal mucosal graft urethroplasty: a novel surgical technique for the management of urethral stricture disease.

    Science.gov (United States)

    Kovell, Robert Caleb; Terlecki, Ryan Patrick

    2015-02-01

    To describe the novel technique of ventral inlay substitution urethroplasty for the management of male anterior urethral stricture disease. A 58-year-old gentleman with multifocal bulbar stricture disease measuring 7 cm in length was treated using a ventral inlay substitution urethroplasty. A dorsal urethrotomy was created, and the ventral urethral plated was incised. The edges of the urethral plate were mobilized without violation of the ventral corpus spongiosum. A buccal mucosa graft was harvested and affixed as a ventral inlay to augment the caliber of the urethra. The dorsal urethrotomy was closed over a foley catheter. No intraoperative or postoperative complications occurred. Postoperative imaging demonstrated a widely patent urethra. After three years of follow-up, the patient continues to do well with no voiding complaints and low postvoid residuals. Ventral inlay substitution urethroplasty appears to be a safe and feasible technique for the management of bulbar urethral strictures.

  17. Isotretinoin-induced urethritis versus non-gonococcal urethritis in a man who has sex with men: an open debate.

    Science.gov (United States)

    Ballout, Rami A; Maatouk, Ismael

    2018-01-01

    This is the case of a young man presenting with urethritis despite a negative infectious work-up. Careful history taking elucidated a strong correlation between symptom onset and a recent dose escalation of isotretinoin for treatment of his refractory cystic acne. The urethral symptoms quickly resolved with dose reduction, suggesting urethritis as a rare adverse reaction of isotretinoin.

  18. Propagation of Radiosonde Pressure Sensor Errors to Ozonesonde Measurements

    Science.gov (United States)

    Stauffer, R. M.; Morris, G.A.; Thompson, A. M.; Joseph, E.; Coetzee, G. J. R.; Nalli, N. R.

    2014-01-01

    Several previous studies highlight pressure (or equivalently, pressure altitude) discrepancies between the radiosonde pressure sensor and that derived from a GPS flown with the radiosonde. The offsets vary during the ascent both in absolute and percent pressure differences. To investigate this problem further, a total of 731 radiosonde-ozonesonde launches from the Southern Hemisphere subtropics to Northern mid-latitudes are considered, with launches between 2005 - 2013 from both longer-term and campaign-based intensive stations. Five series of radiosondes from two manufacturers (International Met Systems: iMet, iMet-P, iMet-S, and Vaisala: RS80-15N and RS92-SGP) are analyzed to determine the magnitude of the pressure offset. Additionally, electrochemical concentration cell (ECC) ozonesondes from three manufacturers (Science Pump Corporation; SPC and ENSCI-Droplet Measurement Technologies; DMT) are analyzed to quantify the effects these offsets have on the calculation of ECC ozone (O3) mixing ratio profiles (O3MR) from the ozonesonde-measured partial pressure. Approximately half of all offsets are 0.6 hPa in the free troposphere, with nearly a third 1.0 hPa at 26 km, where the 1.0 hPa error represents 5 persent of the total atmospheric pressure. Pressure offsets have negligible effects on O3MR below 20 km (96 percent of launches lie within 5 percent O3MR error at 20 km). Ozone mixing ratio errors above 10 hPa (30 km), can approach greater than 10 percent ( 25 percent of launches that reach 30 km exceed this threshold). These errors cause disagreement between the integrated ozonesonde-only column O3 from the GPS and radiosonde pressure profile by an average of +6.5 DU. Comparisons of total column O3 between the GPS and radiosonde pressure profiles yield average differences of +1.1 DU when the O3 is integrated to burst with addition of the McPeters and Labow (2012) above-burst O3 column climatology. Total column differences are reduced to an average of -0.5 DU when

  19. Falls event detection using triaxial accelerometry and barometric pressure measurement.

    Science.gov (United States)

    Bianchi, Federico; Redmond, Stephen J; Narayanan, Michael R; Cerutti, Sergio; Celler, Branko G; Lovell, Nigel H

    2009-01-01

    A falls detection system, employing a Bluetooth-based wearable device, containing a triaxial accelerometer and a barometric pressure sensor, is described. The aim of this study is to evaluate the use of barometric pressure measurement, as a surrogate measure of altitude, to augment previously reported accelerometry-based falls detection algorithms. The accelerometry and barometric pressure signals obtained from the waist-mounted device are analyzed by a signal processing and classification algorithm to discriminate falls from activities of daily living. This falls detection algorithm has been compared to two existing algorithms which utilize accelerometry signals alone. A set of laboratory-based simulated falls, along with other tasks associated with activities of daily living (16 tests) were performed by 15 healthy volunteers (9 male and 6 female; age: 23.7 +/- 2.9 years; height: 1.74 +/- 0.11 m). The algorithm incorporating pressure information detected falls with the highest sensitivity (97.8%) and the highest specificity (96.7%).

  20. Contemporary Management of Primary Distal Urethral Cancer.

    Science.gov (United States)

    Traboulsi, Samer L; Witjes, Johannes Alfred; Kassouf, Wassim

    2016-11-01

    Primary urethral cancer is one of the rare urologic tumors. Distal urethral tumors are usually less advanced at diagnosis compared with proximal tumors and have a good prognosis if treated appropriately. Low-stage distal tumors can be managed successfully with a surgical approach in men or radiation therapy in women. There are no clear-cut indications for the choice of the most appropriate treatment modality. Organ-preserving modalities have shown effective and should be used whenever they do not compromise the oncological safety to decrease the physical and psychological trauma of dismemberment or loss of sexual/urinary function. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. How important is the recommended slow cuff pressure deflation rate for blood pressure measurement?

    Science.gov (United States)

    Zheng, Dingchang; Amoore, John N; Mieke, Stephan; Murray, Alan

    2011-10-01

    Cuff pressure deflation rate influences blood pressure (BP) measurement. However, there is little quantitative clinical evidence on its effect. Oscillometric pulses recorded from 75 subjects at the recommended deflation rate of 2-3 mmHg per second were analyzed. Some pulses were removed to realize six faster rates (2-7 times faster than the original). Systolic, diastolic, and mean arterial blood pressures (SBP, DBP, MAP) were determined from the original and six reconstructed oscillometric waveforms. Manual measurement was based on the appearance of oscillometric pulse peaks, and automatic measurement on two model envelopes (linear and polynomial) fitted to the sequence of oscillometric pulse amplitudes. The effects of deflation rate on BP determination and within-subject BP variability were analyzed. For SBP and DBP determined from the manual measurement, different deflation rates resulted in significant changes (both p deflation rate effect (all p > 0.3). Faster deflation increased the within-subject BP variability (all p deflation rate, and for the automatic model-based techniques, the deflation rate had little effect.

  2. Comparison of current tonometry techniques in measurement of intraocular pressure.

    Science.gov (United States)

    Kouchaki, Behrooz; Hashemi, Hassan; Yekta, Abbasali; Khabazkhoob, Mehdi

    2017-06-01

    To compare four tonometry techniques: Goldmann applanation tonometer (GAT), Dynamic contour tonometer (DCT), Non-contact tonometer (NCT), and Ocular Response Analyzer (ORA) in the measurement of intraocular pressure (IOP) and the impact of some corneal biomechanical factors on their performance. In this cross-sectional study, volunteers with normal ophthalmic examination and no history of eye surgery (except for uncomplicated cataract surgery) or trauma were selected. Twenty-five subjects were male, and 21 were female. The mean age was 48 ± 19.2 years. Anterior segment parameters were measured with Scheimpflug imaging. IOP was measured with GAT, DCT, NCT, and ORA in random order. A 95% limit of agreement of IOPs was analyzed. The impact of different parameters on the measured IOP with each device was evaluated by regression analysis. The average IOP measured with GAT, DCT, NCT, and ORA was 16.4 ± 3.5, 18.1 ± 3.4, 16.2 ± 3.9, and 17.3 ± 3.4 mmHg, respectively. The difference of IOP measured with NCT and GAT was not significant ( P  = 0.382). Intraocular pressure was significantly different between GAT with DCT and IOP CC ( P  tonometers.

  3. Measurement of viscosity of gaseous mixtures at atmospheric pressure

    Science.gov (United States)

    Singh, J. J.; Mall, G. H.; Chegini, H.

    1986-01-01

    Coefficients of viscosity of various types of gas mixtures, including simulated natural-gas samples, have been measured at atmospheric pressure and room temperature using a modified capillary tube method. Pressure drops across the straight capillary tube section of a thermal mass flowmeter were measured for small, well-defined, volume flow rates for the test gases and for standard air. In this configuration, the flowmeter provides the volumetric flow rates as well as a well-characterized capillary section for differential pressure measurements across it. The coefficients of viscosity of the test gases were calculated using the reported value of 185.6 micro P for the viscosity of air. The coefficients of viscosity for the test mixtures were also calculated using Wilke's approximation of the Chapman-Enskog (C-E) theory. The experimental and calculated values for binary mixtures are in agreement within the reported accuracy of Wilke's approximation of the C-E theory. However, the agreement for multicomponent mixtures is less satisfactory, possible because of the limitations of Wilkes's approximation of the classical dilute-gas state model.

  4. Deferred endoscopic urethral realignment: Role in management of traumatic posterior urethral disruption

    Directory of Open Access Journals (Sweden)

    M.A. Elgammal

    2014-06-01

    Conclusion: When early realignment is postponed for any reason, deferred endoscopic realignment is considered an adequate substitute because urethral continuity can be achieved in a group of patients without increase incidence of impotence and incontinence.

  5. Photoluminescence excitation measurements using pressure-tuned laser diodes

    Science.gov (United States)

    Bercha, Artem; Ivonyak, Yurii; Medryk, Radosław; Trzeciakowski, Witold A.; Dybała, Filip; Piechal, Bernard

    2015-06-01

    Pressure-tuned laser diodes in external cavity were used as tunable sources for photoluminescence excitation (PLE) spectroscopy. The method was demonstrated in the 720 nm-1070 nm spectral range using a few commercial laser diodes. The samples for PLE measurements were quantum-well structures grown on GaAs and on InP. The method is superior to standard PLE measurements using titanium sapphire laser because it can be extended to any spectral range where anti-reflection coated laser diodes are available.

  6. Photoluminescence excitation measurements using pressure-tuned laser diodes

    International Nuclear Information System (INIS)

    Bercha, Artem; Ivonyak, Yurii; Mędryk, Radosław; Trzeciakowski, Witold A.; Dybała, Filip; Piechal, Bernard

    2015-01-01

    Pressure-tuned laser diodes in external cavity were used as tunable sources for photoluminescence excitation (PLE) spectroscopy. The method was demonstrated in the 720 nm-1070 nm spectral range using a few commercial laser diodes. The samples for PLE measurements were quantum-well structures grown on GaAs and on InP. The method is superior to standard PLE measurements using titanium sapphire laser because it can be extended to any spectral range where anti-reflection coated laser diodes are available

  7. Prospective blood pressure measurement in renal transplant recipients.

    Science.gov (United States)

    David, V G; Yadav, B; Jeyaseelan, L; Deborah, M N; Jacob, S; Alexander, S; Varughese, S; John, G T

    2014-05-01

    Blood pressure (BP) control at home is difficult when managed only with office blood pressure monitoring (OBPM). In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM) was compared with ambulatory blood pressure monitoring (ABPM) as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2(nd), 4(th), 6(th), and 9(th) months and all the three methods: OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%). Systolic BP (SBP) and diastolic BP (DBP) measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa: 0.88 vs. 89% specificity, Kappa: 0.71). HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa: 0.71 vs. 50% specificity Kappa: 0.54). In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  8. Prospective blood pressure measurement in renal transplant recipients

    Directory of Open Access Journals (Sweden)

    V G David

    2014-01-01

    Full Text Available Blood pressure (BP control at home is difficult when managed only with office blood pressure monitoring (OBPM. In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM was compared with ambulatory blood pressure monitoring (ABPM as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2 nd , 4 th , 6 th , and 9 th months and all the three methods : OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%. Systolic BP (SBP and diastolic BP (DBP measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa : 0.88 vs. 89% specificity, Kappa : 0.71. HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa : 0.71 vs. 50% specificity Kappa : 0.54. In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  9. New calibration method for I-scan sensors to enable the precise measurement of pressures delivered by 'pressure garments'.

    Science.gov (United States)

    Macintyre, Lisa

    2011-11-01

    Accurate measurement of the pressure delivered by medical compression products is highly desirable both in monitoring treatment and in developing new pressure inducing garments or products. There are several complications in measuring pressure at the garment/body interface and at present no ideal pressure measurement tool exists for this purpose. This paper summarises a thorough evaluation of the accuracy and reproducibility of measurements taken following both of Tekscan Inc.'s recommended calibration procedures for I-scan sensors; and presents an improved method for calibrating and using I-scan pressure sensors. The proposed calibration method enables accurate (±2.1 mmHg) measurement of pressures delivered by pressure garments to body parts with a circumference ≥30 cm. This method is too cumbersome for routine clinical use but is very useful, accurate and reproducible for product development or clinical evaluation purposes. Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.

  10. A noncontact intraocular pressure measurement device using a micro reflected air pressure sensor for the prediagnosis of glaucoma

    International Nuclear Information System (INIS)

    Kim, Kyoung Hwan; Kim, Byeong Hee; Seo, Young Ho

    2012-01-01

    This study investigates a novel, portable tonometer using a micro reflected air pressure sensor for the prediagnosis of glaucoma. Because glaucoma progresses slowly and is not painful, glaucoma patients require a portable prediagnosis system to periodically measure intraocular pressure at home. Conventionally, intraocular pressure is measured by an air-puff tonometer whereby the cornea is deformed by a short pulse of air pressure and the magnitude of the corneal deformation is measured by optic systems such as a combination of laser- and photodiodes. In this study, a micro reflected air pressure sensor was designed, fabricated, and tested in order to measure the magnitude of corneal deformation without optic systems. In an experimental study, artificial eyes with different internal pressures were fabricated and these pressures were measured by the aforementioned system. (paper)

  11. Female urethral strictures: successful management with long-term clean intermittent catheterization after urethral dilatation.

    Science.gov (United States)

    Smith, Ariana L; Ferlise, Victor J; Rovner, Eric S

    2006-07-01

    To report our experience in the diagnosis and treatment of urethral stricture in women. A retrospective review of records and video-urodynamics identified women treated for urethral stricture between 1999 and 2004 at one institution by one surgeon. Urethral stricture was defined as a fixed anatomical narrowing between the bladder neck and distal urethra of or = 30 F. After a period of indwelling catheterization, the women were placed on clean intermittent self-catheterization (CISC) at least once daily, and monitored every 3-6 months. At each follow-up, the urethra was catheterized to exclude recurrence. American Urological Association (AUA) symptom scores were obtained at presentation and at the initial 3 month follow-up. Seven women met the criteria for urethral stricture, and were followed for a mean (range) of 21 (6-34) months. All were initially maintained on daily CISC, and some were gradually reduced to weekly CISC for the duration of follow-up. No patient had a recurrent stricture while on CISC, and none has had a urethral reconstruction to manage their condition. AUA symptom scores improved in all of the women by a mean of 10.7 points. No complications related to catheterization were noted. Urethral stricture is rare in women. Long-term CISC in these women is safe and effective, and can avoid the need for major reconstructive surgery.

  12. Interpreting Aerodynamics of a Transonic Impeller from Static Pressure Measurements

    Directory of Open Access Journals (Sweden)

    Fangyuan Lou

    2018-01-01

    Full Text Available This paper investigates the aerodynamics of a transonic impeller using static pressure measurements. The impeller is a high-speed, high-pressure-ratio wheel used in small gas turbine engines. The experiment was conducted on the single stage centrifugal compressor facility in the compressor research laboratory at Purdue University. Data were acquired from choke to near-surge at four different corrected speeds (Nc from 80% to 100% design speed, which covers both subsonic and supersonic inlet conditions. Details of the impeller flow field are discussed using data acquired from both steady and time-resolved static pressure measurements along the impeller shroud. The flow field is compared at different loading conditions, from subsonic to supersonic inlet conditions. The impeller performance was strongly dependent on the inducer, where the majority of relative diffusion occurs. The inducer diffuses flow more efficiently for inlet tip relative Mach numbers close to unity, and the performance diminishes at other Mach numbers. Shock waves emerging upstream of the impeller leading edge were observed from 90% to 100% corrected speed, and they move towards the impeller trailing edge as the inlet tip relative Mach number increases. There is no shock wave present in the inducer at 80% corrected speed. However, a high-loss region near the inducer throat was observed at 80% corrected speed resulting in a lower impeller efficiency at subsonic inlet conditions.

  13. Measurement of the pressure pulse from a detonating explosive

    International Nuclear Information System (INIS)

    Bourne, N K; Milne, A M; Biers, R A

    2005-01-01

    A series of experiments has been carried out to determine the pressure pulse exiting from a polymethylmethacrylate (PMMA) plate, of varying thickness, subject to the shock pulse exerted by a detonating charge of fixed mass. This calibration will define a new donor explosive and inert gap material for use in one of the qualification tests for energetic materials, the large scale gap test. The peak pressure was recorded on the central axis of the attenuator using calibrated piezoresistive manganin gauges as a function of the quantity of PMMA applied to the output of the donor charge. The stress history within the PMMA was measured as a function of run distance and the peak pressure plotted against thickness as a calibration. The shock front was known to have curvature and a measurement of this was attempted. The behaviour of the transmitted shock at small gap thicknesses was shown to be anomalous since the front was partially in a reactive and partially within an inert medium

  14. Incomplete urethral duplication in an adult male.

    LENUS (Irish Health Repository)

    Davis, N F

    2012-09-01

    Urethral duplication is a rare congenital anomaly with less than 200 cases reported. It predominantly occurs in males and is nearly always diagnosed in childhood or adolescence. It is defined as a complete second passage from the bladder to the dorsum of the penis or as an accessory pathway that ends blindly on the dorsal or ventral surface.

  15. Early endoscopic realignment in posterior urethral injuries.

    Science.gov (United States)

    Shrestha, B; Baidya, J L

    2013-01-01

    Posterior urethral injury requires meticulous tertiary care and optimum expertise to manage successfully. The aim of our study is to describe our experiences with pelvic injuries involving posterior urethra and their outcome after early endoscopic realignment. A prospective study was carried out in 20 patients with complete posterior urethral rupture, from November 2007 till October 2010. They presented with blunt traumatic pelvic fracture and underwent primary realignment of posterior urethra in our institute. The definitive diagnosis of urethral rupture was made after retrograde urethrography and antegrade urethrography where applicable. The initial management was suprapubic catheter insertion after primary trauma management in casualty. After a week of conservative management with intravenous antibiotics and pain management, patients were subjected to the endoscopic realignment. The follow up period was at least six months. The results were analyzed with SPSS software. After endoscopic realignment, all patients were advised CISC for the initial 3 months. All patients voided well after three months of CISC. However, 12 patients were lost to follow up by the end of 6 postoperative months. Out of eight remaining patients, two had features of restricture and were managed with DVU followed by CISC again. One patient with restricture had some degree of erectile dysfunction who improved significantly after phospodiesterase inhibitors. None of the patients had features of incontinence. Early endoscopic realignment of posterior urethra is a minimally invasive modality in the management of complete posterior urethral injury with low rates of incontinence and impotency.

  16. Male Urethral Diverticulum Having Multiple Stones

    African Journals Online (AJOL)

    muscle fibers in their wall, commonly encountered in adults, and involve the posterior urethra. Differential diagnosis for UD includes syringoceles (cystic dilatation of the Cowper's gland), sequestration cysts, epidermoid and epithelial inclusion cysts. Male Urethral Diverticulum Having Multiple Stones. Mohanty D, Garg PK, ...

  17. A user's guide to intra-abdominal pressure measurement.

    LENUS (Irish Health Repository)

    Sugrue, Michael

    2015-01-01

    The intra-abdominal pressure (IAP) measurement is a key to diagnosing and managing critically ill medical and surgical patients. There are an increasing number of techniques that allow us to measure the IAP at the bedside. This paper reviews these techniques. IAP should be measured at end-expiration, with the patient in the supine position and ensuring that there is no abdominal muscle activity. The intravesicular IAP measurement is convenient and considered the gold standard. The level where the mid-axillary line crosses the iliac crest is the recommended zero reference for the transvesicular IAP measurement; moreover, marking this level on the patient increases reproducibility. Protocols for IAP measurement should be developed for each ICU based on the locally available tools and equipment. IAP measurement techniques are safe, reproducible and accurate and do not increase the risk of urinary tract infection. Continuous IAP measurement may offer benefits in specific situations in the future. In conclusion, the IAP measurement is a reliable and essential adjunct to the management of patients at risk of intra-abdominal hypertension.

  18. [Urethroplasty with transection of urethral orifice and preservation and lengthening of urethral plate: highly applicable to the treatment of hypospadias].

    Science.gov (United States)

    Wang, Wen-Min; Qiu, Wei-Feng; Qian, Chong

    2010-07-01

    To explore the feasibility of urethroplasty with transection of the urethral orifice and preservation and lengthening of the urethral plate in the treatment of hypospadias. Forty-eight patients with hypospadias (18 of the coronal type, 21 the penile type, 8 the penoscrotal type and 1 the perineal type) underwent urethroplasty with transection of the urethral orifice and preservation and lengthening of the urethral plate. The surgical effects were observed by following up the patients for 3-27 months. One-stage surgical success was achieved in 44 of the cases, with satisfactory functional and cosmetic results but no complications. Two cases developed urinary fistula and another 2 urethral stricture, but all cured by the second surgery. Urethroplasty with transection of the urethral orifice and preservation and lengthening of the urethral plate is a simple, safe and effective surgical procedure for the treatment of hypospadias.

  19. Measurement of local void fraction at elevated temperature and pressure

    International Nuclear Information System (INIS)

    Duncan, D.; Trabold, T.A.

    1993-03-01

    Significant advances have recently been made in analytical and computational methods for the prediction of local thermal-hydraulic conditions in gas/liquid two-phase flows. There is, however, a need for extensive experimental data, for the dual purposes of constitutive relation development and code qualification. There is especially true of systems involving complicated geometries and/or extreme flow conditions for which little, if any, applicable information exists in the open literature. For the tests described in the present paper, a novel electrical probe has been applied to measure the void fraction in atmospheric pressure air/water flows, and steam/water mixtures at high temperature and pressure. The data acquired in the latter experiments are compared with the results of a one-dimensional two-fluid computational analysis

  20. Redo-urethroplasty in pelvic fracture urethral distraction defect: an audit.

    Science.gov (United States)

    Bhagat, Suresh K; Gopalakrishnan, Ganesh; Kumar, Santosh; Devasia, Antony; Kekre, Nitin S

    2011-02-01

    To predict the outcome of redo-urethroplasty after failed single or multiple open urethral procedures for pelvic fracture urethral distraction defects. From January 1997 to December 2006, 43 patients underwent redo-urethroplasty for pelvic fracture urethral distraction defect. Forty-one were referred from other centers. All had undergone open surgery along with an endoscopic procedure (one or more procedures in each patient) which included endoscopic internal urethrotomy, urethral stenting or urethral dilations. There were 43 men with mean age of 29 (range 11-52). Eleven had associated injuries: intraperitoneal bladder rupture (3), bladder neck (2), rectum (3), anal sphincter (2), combined bladder, rectum and anal sphincter (1). Trocar suprapubic cystostomy was performed in 22, rail-road procedures in 10 and open suprapubic cystostomy in 11 along with the management of associated injuries as immediate treatment. Of 43 patients, 28 had progressive perineal, and 12 had transpubic repair. Three patients had total bulbar necrosis, and they underwent prepuceal tube reconstruction (1) and staged substitution with BMG and standard scrotal inlay (2). Analysis of various factors like number of attempts at previous surgery and stricture length did not affect the outcome. A successful result was achieved in 36 (83.72%), improved and stable in five and failure in two. The overall result of redo-urethroplasty for pelvic fracture urethral distraction defect continues to be gratifying. Failures happen usually within the first 3 months. Substitution urethroplasty can be reserved for those who have long distraction defect. Long-term follow-up is essential using stringent criteria to measure success.

  1. Interpretation of strain measurements on nuclear pressure vessels

    International Nuclear Information System (INIS)

    Andersen, S.I.; Engbaek, P.

    1979-11-01

    Selected results from strain measurements on 4 nuclear pressure vessels are presented and discussed. The measurements were made in several different regions of the vessels: transition zones in vessel heads, flanges and bottom parts, nozzels, internal vessel structure and flange bolts. The results presented are based on data obtained by approximately 700 strain-gauges, and a comprehensive knowledge of the quality obtained by such measurements is established. It is shown that a thorough control procedure before and after the test as well as detailed knowledge of the behaviour of the signal from the individual gauges during the test is necessary. If this is omitted, it can be extremely difficult to distinguish between the real structural behaviour and a malfunctioning of a specific gauge installation. In general, most of the measuring results exhibit a very linear behaviour with a negligible zeroshift. However, deviations from linear behaviour are observed in several cases. This nonlinearity can be explained by friction (flange connections) or by gaps (concentrical nozzles) in certain regions, whereas local plastic deformations during the first pressure loadings of the vessel seem to be the reason in other regions. (author)

  2. Dynamic pressure measures for long pipeline leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Likun Wang; Hongchao Wang; Min Xiong; Bin Xu; Dongjie Tan; Hengzhang Zhou [PetroChina Pipeline Company, Langfang (China). R and D Center

    2009-07-01

    Pipeline leak detection method based on dynamic pressure is studied. The feature of dynamic pressure which is generated by the leakage of pipeline is analyzed. The dynamic pressure method is compared with the static pressure method for the advantages and disadvantages in pipeline leak detection. The dynamic pressure signal is suitable for pipeline leak detection for quick-change of pipeline internal pressure. Field tests show that the dynamic pressure method detects pipeline leak rapidly and precisely. (author)

  3. Comparison of three protocols for measuring the maximal respiratory pressures

    Directory of Open Access Journals (Sweden)

    Isabela Maria B. Sclauser Pessoa

    Full Text Available Introduction To avoid the selection of submaximal efforts during the assessment of maximal inspiratory and expiratory pressures (MIP and MEP, some reproducibility criteria have been suggested. Criteria that stand out are those proposed by the American Thoracic Society (ATS and European Respiratory Society (ERS and by the Brazilian Thoracic Association (BTA. However, no studies were found that compared these criteria or assessed the combination of both protocols. Objectives To assess the pressure values selected and the number of maneuvers required to achieve maximum performance using the reproducibility criteria proposed by the ATS/ERS, the BTA and the present study. Materials and method 113 healthy subjects (43.04 ± 16.94 years from both genders were assessed according to the criteria proposed by the ATS/ERS, BTA and the present study. Descriptive statistics were used for analysis, followed by ANOVA for repeated measures and post hoc LSD or by Friedman test and post hoc Wilcoxon, according to the data distribution. Results The criterion proposed by the present study resulted in a significantly higher number of maneuvers (MIP and MEP – median and 25%-75% interquartile range: 5[5-6], 4[3-5] and 3[3-4] for the present study criterion, BTA and ATS/ERS, respectively; p < 0.01 and higher pressure values (MIP – mean and 95% confidence interval: 103[91.43-103.72], 100[97.19-108.83] and 97.6[94.06-105.95]; MEP: median and 25%-75% interquartile range: 124.2[101.4-165.9], 123.3[95.4-153.8] and 118.4[95.5-152.7]; p < 0.05. Conclusion The proposed criterion resulted in the selection of pressure values closer to the individual’s maximal capacity. This new criterion should be considered in future studies concerning MIP and MEP measurements.

  4. Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure

    NARCIS (Netherlands)

    Imholz, B. P.; Settels, J. J.; van der Meiracker, A. H.; Wesseling, K. H.; Wieling, W.

    1990-01-01

    The aim of the study was to evaluate whether invasive blood pressure responses to orthostatic stress can be replaced by non-invasive continuous finger blood pressure responses. DESIGN - Intrabrachial and Finapres blood pressures were simultaneously measured during passive head up tilt and during

  5. Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences.

    Science.gov (United States)

    van der Hoeven, Niels V; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A; van den Born, Bert-Jan H

    2013-11-01

    There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age (simultaneous and three sequential BP measurements were taken in each patient. Starting measurement type and starting arm for sequential measurements were randomized. Mean BP and inter-arm BP differences of the first pair and reproducibility of inter-arm BP differences of the first and second pair were compared between both methods. Mean systolic BP was 1.3±7.5 mm Hg lower during sequential compared with simultaneous measurement (Psequential measurement was on average higher than the second, suggesting an order effect. Absolute systolic inter-arm BP differences were smaller on simultaneous (6.2±6.7/3.3±3.5 mm Hg) compared with sequential BP measurement (7.8±7.3/4.6±5.6 mm Hg, PSimultaneous measurement of BP at both arms reduces order effects and results in smaller inter-arm BP differences, thereby potentially reducing unnecessary referral and diagnostic procedures. ©2013 Wiley Periodicals, Inc.

  6. Temperature measurement in low pressure plasmas. Temperaturmessungen im Niederdruckplasma

    Energy Technology Data Exchange (ETDEWEB)

    Rosenbauer, K.A.; Wilting, H.; Schramm, G. (Duesseldorf Univ. (Germany, F.R.). Abt. fuer Histologie und Embryologie)

    1989-11-01

    The present work discusses the influence of various parameters on the substrate temperature in a low pressure plasma. The measurement method chosen utilized Signotherm (Merck) temperature sensors embedded in silicon between two glass substrates. All measurements were made in a 200 G Plasma Processor from Technics Plasma GmbH. The substrate temperature is dependent on the process time, the RF power, the process gas and the position in the chamber. The substrate temperature increases with increasing process time and increasing power. Due to the location of the microwave port from the magnetron to the chamber, the substrate temperature is highest in the center of the chamber. Measurements performed in an air plasma yielded higher results than in an oxygen plasma. (orig.).

  7. Step Prediction During Perturbed Standing Using Center Of Pressure Measurements

    Directory of Open Access Journals (Sweden)

    Milos R. Popovic

    2007-04-01

    Full Text Available The development of a sensor that can measure balance during quiet standing and predict stepping response in the event of perturbation has many clinically relevant applica- tions, including closed-loop control of a neuroprothesis for standing. This study investigated the feasibility of an algorithm that can predict in real-time when an able-bodied individual who is quietly standing will have to make a step to compensate for an external perturbation. Anterior and posterior perturbations were performed on 16 able-bodied subjects using a pul- ley system with a dropped weight. A linear relationship was found between the peak center of pressure (COP velocity and the peak COP displacement caused by the perturbation. This result suggests that one can predict when a person will have to make a step based on COP velocity measurements alone. Another important feature of this finding is that the peak COP velocity occurs considerably before the peak COP displacement. As a result, one can predict if a subject will have to make a step in response to a perturbation sufficiently ahead of the time when the subject is actually forced to make the step. The proposed instability detection algorithm will be implemented in a sensor system using insole sheets in shoes with minitur- ized pressure sensors by which the COPv can be continuously measured. The sensor system will be integrated in a closed-loop feedback system with a neuroprosthesis for standing in the near future.

  8. Out-of-office blood pressure: from measurement to control

    Directory of Open Access Journals (Sweden)

    Baguet JP

    2012-05-01

    Full Text Available Jean-Philippe Baguet1,21Department of Cardiology, University Hospital, 2Bioclinic Radiopharmaceutics Laboratory, INSERM U1039, Joseph Fourier University, Grenoble, FranceAbstract: Hypertension is an important risk factor for the development of cardiovascular disease, and is a major cause of morbidity and mortality worldwide. Traditionally, hypertension diagnosis and treatment and clinical evaluations of antihypertensive efficacy have been based on office blood pressure (BP measurements; however, there is increasing evidence that office measures may provide inadequate or misleading estimates of a patient’s true BP status and level of cardiovascular risk. The introduction, and endorsement by treatment guidelines, of 24-hour ambulatory BP monitoring and self (or home BP monitoring has facilitated more reliable and reproducible estimations of true BP, including the identification of white-coat and masked hypertension, and evaluation of BP variability. In addition, ambulatory BP monitoring enables accurate assessment of treatment effectiveness over 24 hours and both ambulatory and self BP monitoring may lead to better tailoring of therapy according to BP profile and concomitant disease. This review describes the clinical benefits and limitations of out-of-office assessments and their applications for effective management of hypertension and attainment of BP control.Keywords: ambulatory, ABPM, SBPM, blood pressure measurement, hypertension

  9. Measuring and understanding total dissolved gas pressure in groundwater

    Science.gov (United States)

    Ryan, C.; Roy, J. W.; Randell, J.; Castellon, L.

    2009-05-01

    Since dissolved gases are important to a number of aspects of groundwater (e.g. age dating, active or passive bioremediation, greenhouse gas fluxes, understanding biogeochemical processes involving gases, assessing potential impacts of coal bed methane activities), accurate concentration measurements, and understanding of their subsurface behaviour are important. Researchers have recently begun using total dissolved gas pressure (TGP) sensor measurements, more commonly applied for surface water monitoring, in concert with gas composition analyses to estimate more accurate groundwater gas concentrations in wells. We have used hydraulic packers to isolate the well screens where TDP is being measured, and pump tests to indicate that in-well degassing may reduce TDG below background groundwater levels. Thus, in gas-charged groundwater zones, TGPs can be considerably underestimated in the absence of pumping or screen isolation. We have also observed transient decreased TGPs during pumping that are thought to result from ebullition induced when the water table or water level in the well is lowered below a critical hydrostatic pressure.

  10. Prospective Comparative Analysis of 4 Different Intraocular Pressure Measurement Techniques and Their Effects on Pressure Readings.

    Science.gov (United States)

    Berk, Thomas A; Yang, Patrick T; Chan, Clara C

    2016-10-01

    To compare intraocular pressure (IOP) measurement using the Goldmann applanation tonometry (GAT) without fluorescein, with fluorescein strips, with fluorescein droplets, and IOP measurement with Tono-Pen Avia (TPA). This was a prospective comparative clinical analysis. It was performed in clinical practice. The study population consisted of 40 volunteer patients, 1 eye per patient. All patients who were 18 years and older having routine ophthalmological examination were eligible to participate. Active corneal abrasions and/or ulcers, previous glaucoma surgery, or prostheses interfering with GAT measurement were excluded. GAT IOP was measured first without fluorescein, then with fluorescein strip, then with fluorescein droplet, and finally with the TPA device. The main outcome measure was central corneal IOP. Mean±SD IOP measurements for GAT without fluorescein, with fluorescein strip, with fluorescein droplet, and for TPA groups were 12.65±3.01, 14.70±2.82, 15.78±2.64, and 16.33±3.08 mm Hg, respectively. Repeated-measures analysis of variance corrected with the Greenhouse-Geisser estimate ([Latin Small Letter Open E]=0.732) showed that measuring technique had a significant effect on IOP measurements (F2.20,85.59=34.66, P<0.001). The pairwise post hoc testing showed statistically significant mean differences (P≤0.001) between all techniques except when GAT with fluorescein droplet was compared with TPA (P=0.222). The Bland-Altman analyses showed 95% limits of agreement maximum potential discrepancies in measurement ranging from 5.89 mm Hg in the GAT with fluorescein strip versus droplet compared with 11.83 mm Hg in the GAT with fluorescein strip versus TPA comparison. IOP measurement technique significantly impacted the values obtained. The ophthalmologist should ensure consistent measurement technique to minimize variability when following patients.

  11. Simulations of piezoelectric pressure sensor for radial artery pulse measurement

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Abhay B. [Department of Electronic Science, University of Pune, Pune 411 007 (India); Kalange, Ashok E. [Department of Electronic Science, University of Pune, Pune 411 007 (India); Tuljaram Chaturchand College, Baramati 413 102 (India); Bodas, Dhananjay, E-mail: dhananjay.bodas@gmail.co [Center for Nanobio Sciences, Agharkar Research Institute, Pune 411 004 (India); Gangal, S.A. [Department of Electronic Science, University of Pune, Pune 411 007 (India)

    2010-04-15

    A radial artery pulse is used to diagnose human body constitution (Prakruti) in Ayurveda. A system consisting of piezoelectric sensor (22 mm x 12 mm), data acquisition card and LabView software was used to record the pulse data. The pulse obtained from the sensor was noisy, even though signal processing was done. Moreover due to large sized senor accurate measurements were not possible. Hence, a need was felt to develop a sensor of the size of the order of finger tip with a resonant frequency of the order of 1 Hz. A micromachined pressure sensor based on piezoelectric sensing mechanism was designed and simulated using CoventorWare. Simulations were carried out by varying dimensions of the sensor to optimize the resonant frequency, stresses and voltage generated as a function of applied pressure. All simulations were done with pressure ranging of 1-30 kPa, which is the range used by Ayurvedic practitioners for diagnosis. Preliminary work on fabrication of such a sensor was carried out successfully.

  12. Simulations of piezoelectric pressure sensor for radial artery pulse measurement

    International Nuclear Information System (INIS)

    Joshi, Abhay B.; Kalange, Ashok E.; Bodas, Dhananjay; Gangal, S.A.

    2010-01-01

    A radial artery pulse is used to diagnose human body constitution (Prakruti) in Ayurveda. A system consisting of piezoelectric sensor (22 mm x 12 mm), data acquisition card and LabView software was used to record the pulse data. The pulse obtained from the sensor was noisy, even though signal processing was done. Moreover due to large sized senor accurate measurements were not possible. Hence, a need was felt to develop a sensor of the size of the order of finger tip with a resonant frequency of the order of 1 Hz. A micromachined pressure sensor based on piezoelectric sensing mechanism was designed and simulated using CoventorWare. Simulations were carried out by varying dimensions of the sensor to optimize the resonant frequency, stresses and voltage generated as a function of applied pressure. All simulations were done with pressure ranging of 1-30 kPa, which is the range used by Ayurvedic practitioners for diagnosis. Preliminary work on fabrication of such a sensor was carried out successfully.

  13. Fast pressure measurements for the TMX-U fusion experiment

    International Nuclear Information System (INIS)

    Hunt, A.L.; Coffield, F.E.; Pickles, W.L.

    1982-01-01

    The pressure on the boundary of the Lawrence Livermore National Laboratory's (LLNL) tandem mirror (TMX-U) plasma experiment is difficult to trace for several reasons: (1) the TMX-U boundary is in the high vacuum range (10 -5 to 10 -6 Pa) and requires an ionization gauge; (2) the boundary includes high-energy neutral particles and radiation, so the gauge must be optically baffled from the plasma; (3) the gauge must be shielded from the magnetic flux density of 0.03 T; (4) maximum conductance to the gauge must be preserved so that the time response remains about 1 ms; (5) a fast electrical circuit is required to measure the small ion-current changes at a rate consistent with the geometrical and experimental time constant of 1 ms. We have developed solutions to these limitations, including fast ionization gauge (FIG) circuitry for the remote gauge operation and the CAMAC system for recording the pressure-time history in the TMX-U computer data base. We also give some examples of actual fast pressure histories during plasma operation

  14. Non-destructive residual pressure self-measurement method for the sensing chip of optical Fabry-Perot pressure sensor.

    Science.gov (United States)

    Wang, Xue; Wang, Shuang; Jiang, Junfeng; Liu, Kun; Zhang, Xuezhi; Xiao, Mengnan; Xiao, Hai; Liu, Tiegen

    2017-12-11

    We introduce a simple residual pressure self-measurement method for the Fabry-Perot (F-P) cavity of optical MEMS pressure sensor. No extra installation is required and the structure of the sensor is unchanged. In the method, the relationship between residual pressure and external pressure under the same diaphragm deflection condition at different temperatures is analyzed by using the deflection formula of the circular plate with clamped edges and the ideal gas law. Based on this, the residual pressure under the flat condition can be obtained by pressure scanning process and calculation process. We carried out the experiment to compare the residual pressures of two batches MEMS sensors fabricated by two kinds of bonding process. The measurement result indicates that our approach is reliable enough for the measurement.

  15. Microscopy of Stained Urethral Smear in Male Urethritis; Which Cutoff Should be Used?

    Science.gov (United States)

    Moi, Harald; Hartgill, Usha; Skullerud, Kristin Helene; Reponen, Elina J; Syvertsen, Line; Moghaddam, Amir

    2017-03-01

    The microscopical diagnosis of male urethritis was recently questioned by Rietmeijer and Mettenbrink, lowering the diagnostic criteria of the diagnosis to ≥2 polymorphonuclear leucocytes (PMNL) per high power field (HPF), and adopted by Centers for Disease Control and Prevention in their 2015 STD Treatment Guidelines. The European Non-Gonococcal Urethritis Guideline advocates a limit of ≥5 PMNL/HPF. To determine if syndromic treatment of urethritis should be considered with a cutoff value of ≥2 PMNL/HPF in urethral smear. The design was a cross-sectional study investigating the presence and degree of urethritis relative to specific infections in men attending an STI clinic as drop-in patients. The material included 2 cohorts: a retrospective study of 13,295 men and a prospective controlled study including 356 men. We observed a mean chlamydia prevalence of 2.3% in the 0-9 stratum, and a 12-fold higher prevalence (27.3%) in the strata above 9. Of the chlamydia cases, 89.8% were diagnosed in strata above 9. For Mycoplasma genitalium, the prevalence was 1.4% in the 0-9 stratum and 11.2% in the stratum ≥10, and 83.6% were diagnosed in strata above 9. For gonorrhea, a significant increase in the prevalence occurred between the 0-30 strata and >30 strata from 0.2% to 20.7%. The results of the prospective study were similar. Our data do not support lowering the cutoff to ≥2 PMNL/HPF. However, a standardization of urethral smear microscopy seems to be impossible. The cutoff value should discriminate between low and high prevalence of chlamydia, mycoplasma, and gonorrhea to include as many as possible with a specific infection in syndromic treatment, without overtreating those with few PMNL/HPF and high possibility of having nonspecific or no urethritis.

  16. Impact of prior urethral manipulation on outcome of anastomotic urethroplasty for post-traumatic urethral stricture.

    Science.gov (United States)

    Singh, Bhupendra P; Andankar, Mukund G; Swain, Sanjaya K; Das, Krishanu; Dassi, Vimal; Kaswan, Harish K; Agrawal, Vipul; Pathak, Hemant R

    2010-01-01

    To determine the impact of earlier urethral interventions on the outcomes of anastomotic urethroplasty in post-traumatic stricture urethra. From October 1995 to March 2008, a total of 58 patients with post-traumatic posterior urethral stricture underwent anastomotic urethroplasty. Eighteen patients had earlier undergone urethral intervention in the form of urethrotomy (3), endoscopic realignment (7), or open urethroplasty (8). Success was defined as no obstructive urinary symptoms, maximum urine flow rate > or = 15 mL/s, normal urethral imaging and/or urethroscopy, and no need of any intervention in the follow-up period. Patients who met the above objective criteria after needing 1 urethrotomy following urethroplasty were defined to have satisfactory outcome and were included in satisfactory result rate along with patients who had a successful outcome. Results were analyzed using unpaired t test, chi-square test, binary logistic regression, Kaplan-Meier curves, and log rank test. Previous interventions in the form of endoscopic realignment or urethroplasty have significant adverse effect on the success rate of subsequent anastomotic urethroplasty for post-traumatic posterior urethral strictures (P urethrotomies (up to 2 times) did not affect the outcome of subsequent anastomotic urethroplasty. Length of stricture and age of patient did not predict the outcome in traumatic posterior urethral strictures in logistic regression analysis. Previous failed railroading or urethroplasty significantly decrease the success of subsequent anastomotic urethroplasty. Hence, a primary realignment or urethroplasty should be avoided in suboptimal conditions and the cases of post-traumatic urethral stricture should be referred to centers with such expertise. 2010 Elsevier Inc. All rights reserved.

  17. Extraction of airfoil data using PIV and pressure measurements

    DEFF Research Database (Denmark)

    Yang, Hua; Shen, Wen Zhong; Sørensen, Jens Nørkær

    2011-01-01

    of the rotor. The extraction technique is verified by employing the derived airfoil characteristics as input to computations using the BEM technique and comparing the calculated axial and tangential forces to the measured data. The comparison also demonstrates that the used technique of determining the AOA...... airfoil data are compared to 2D data from wind tunnel experiments and XFOIL computations. The comparison suggests that the rotor is subject to severe 3D effects originating from the geometry of the rotor, and explains why the Blade Element Momentum technique with 2D airfoil data over‐predicts the loading......A newly developed technique for determining the angle of attack (AOA) on a rotating blade is used to extract AOAs and airfoil data from measurements obtained during the MEXICO (Model rotor EXperiments in COntrolled conditions) rotor experiment. Detailed surface pressure and Particle Image...

  18. Sound field separation with sound pressure and particle velocity measurements

    DEFF Research Database (Denmark)

    Fernandez Grande, Efren; Jacobsen, Finn; Leclère, Quentin

    2012-01-01

    separation techniques make it possible to distinguish between outgoing and incoming waves from the two sides, and thus NAH can be applied. In this paper, a separation method based on the measurement of the particle velocity in two layers and another method based on the measurement of the pressure...... and the velocity in a single layer are proposed. The two methods use an equivalent source formulation with separate transfer matrices for the outgoing and incoming waves, so that the sound from the two sides of the array can be modeled independently. A weighting scheme is proposed to account for the distance......In conventional near-field acoustic holography (NAH) it is not possible to distinguish between sound from the two sides of the array, thus, it is a requirement that all the sources are confined to only one side and radiate into a free field. When this requirement cannot be fulfilled, sound field...

  19. Quantitative Thermochemical Measurements in High-Pressure Gaseous Combustion

    Science.gov (United States)

    Kojima, Jun J.; Fischer, David G.

    2012-01-01

    We present our strategic experiment and thermochemical analyses on combustion flow using a subframe burst gating (SBG) Raman spectroscopy. This unconventional laser diagnostic technique has promising ability to enhance accuracy of the quantitative scalar measurements in a point-wise single-shot fashion. In the presentation, we briefly describe an experimental methodology that generates transferable calibration standard for the routine implementation of the diagnostics in hydrocarbon flames. The diagnostic technology was applied to simultaneous measurements of temperature and chemical species in a swirl-stabilized turbulent flame with gaseous methane fuel at elevated pressure (17 atm). Statistical analyses of the space-/time-resolved thermochemical data provide insights into the nature of the mixing process and it impact on the subsequent combustion process in the model combustor.

  20. Predictors for success of internal urethrotomy in patients with urethral contracture following perineal repair of pelvic fracture urethral injuries.

    Science.gov (United States)

    Hong, Young-Kwon; Choi, Kyung-Hwa; Lee, Young-Tae; Lee, Seung-Ryeol

    2017-05-01

    Internal urethrotomy (IU) in patients with urethral contracture following perineal repair of pelvic fracture urethral injuries (PRPFUI) is troublesome. We evaluated the clinical factors affecting the surgical outcome of IU for urethral contracture after PRPFUI. We retrospectively reviewed the records of 35 patients who underwent IU for urethral contracture after PRPFUI between March 2004 and June 2013. Ages of patients ranged from 18 to 50, and their follow-up duration was more than 1year after IU. The urethral contracture was confirmed by retrograde urethrogram or cysto-urethroscopy. Success was defined as greater than 15mL/s of peak urinary flow rate at 1year after IU without any clinical evidence of urethral contracture. Success rates were investigated according to the number of IU. Age, body mass index, urethral defect length before PRPFUI, time interval between the original urethral injury and the PRPFUI or between a previous operation and the PRPFUI, time interval between the PRPFUI and the urethral contracture, number of PRPFUI performed, and the type of urethral lengthening procedure were compared between patients with and without success according to the number of IU. Among the 35 patients, the overall success rate of IU was 37% (13/35) during the mean follow-up period of 53 months (range: 17-148 months). There were 8 and 5 patients with success in first and second IU, respectively. However, there was no success after third IU. Urethral defect length before PRPFUI was significantly shorter in patients with success who underwent first and second IU (p<0.05). There were significant differences of success between patients with and without previous repeated failures of PRPFUI in first and second IU (p<0.05). Short urethral defect length and no previous surgical failures before PRPFUI are good prognostic factors for IU following PRPFUI. Only one or two IUs will be helpful in patients with urethral contracture following PRPFUI. Copyright © 2017 Elsevier Ltd

  1. Management of non-gonococcal urethritis.

    Science.gov (United States)

    Moi, Harald; Blee, Karla; Horner, Patrick J

    2015-07-29

    Non-gonococcal urethritis (NGU), or inflammation of the urethra, is the most common treatable sexually transmitted syndrome in men, with approximately 20-50 % of cases being due to infection with Chlamydia trachomatis and 10-30 % Mycoplasma genitalium. Other causes are Ureaplasma urealyticum, Trichomonas vaginalis, anaerobes, Herpes simplex virus (HSV) and adenovirus. Up to half of the cases are non-specific. Urethritis is characterized by discharge, dysuria and/or urethral discomfort but may be asymptomatic. The diagnosis of urethritis is confirmed by demonstrating an excess of polymorpho-nuclear leucocytes (PMNLs) in a stained smear. An excess of mononuclear leucocytes in the smear indicates a viral etiology. In patients presenting with symptoms of urethritis, the diagnosis should be confirmed by microscopy of a stained smear, ruling out gonorrhea. Nucleid acid amplifications tests (NAAT) for Neisseria gonorrhoeae, C. trachomatis and for M. genitalium. If viral or protozoan aetiology is suspected, NAAT for HSV, adenovirus and T. vaginalis, if available. If marked symptoms and urethritis is confirmed, syndromic treatment should be given at the first appointment without waiting for the laboratory results. Treatment options are doxycycline 100 mg x 2 for one week or azithromycin 1 gram single dose or 1,5 gram distributed in five days. However, azithromycin as first line treatment without test of cure for M. genitalium and subsequent Moxifloxacin treatment of macrolide resistant strains will select and increase the macrolide resistant strains in the population. If positive for M. genitalium, test of cure samples should be collected no earlier than three weeks after start of treatment. If positive in test of cure, moxifloxacin 400 mg 7-14 days is indicated. Current partner(s) should be tested and treated with the same regimen. They should abstain from intercourse until both have completed treatment. Persistent or recurrent NGU must be confirmed with microscopy

  2. Electrical probe measurements in low and high pressure discharges

    International Nuclear Information System (INIS)

    Andersson, D.

    1976-11-01

    The construction of an apparatus for automatic determination of electron distributions is described, whereafter measurements of electron energy distributions before and after a stationary plasma sheath in a low pressure mercury discharge are presented. The sheath appears at a constriction of the discharge tube. The measurements have been made with a spheric probe, using the second-derivative method, and the results show that the energy distribution on the anode side of the sheath is a sum of a thermal population and an accelerated distribution. Near the sheath the accelerated electrons suffice to carry the discharge current, but far from it the current must be carried by an anisotropy in the thermal part of the distribution function. A comparison is made with calculated distributions. The cross-sections for electron-neutral and Coulomb collisions are not sufficient to account for the damping of the accelerated population, suggesting the presence of a plasma instability. In order to study the distribution function of the axial velocity component, preliminary measurements of the first derivative of the current to a plane probe have been made. Such measurements yield information about the anisotropy and the current transport, and may perhaps shed some light on the phenomenon of current limitation. Some measurements on a TIG welding arc are also described. (Auth.)

  3. Measurement of micro Bubbles generated by a pressurized dissolution method

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, S; Tanaka, K; Tomiyama, A [Kobe University, 1-1 Rokkodai, Nada, Kobe 657-8501 (Japan); Maeda, Y; Yamaguchi, S; Ito, Y, E-mail: hosokawa@mech.kobe-u.ac.j [Panasonic Electric Works Co., Ltd., 1048 Kadoma, Osaka 571-8686 (Japan)

    2009-02-01

    Diameters of micro-bubbles are apt to range from about one mm to several-hundred mm, and therefore, it is difficult to measure a correct diameter distribution using a single measurement method. In this study, diameters of bubbles generated by a pressurized dissolution method are measured by using phase Doppler anemometry (PDA) and an image processing method, which is based on the Sobel filter and Hough transform. The diameter distribution and the Sauter mean diameter of micro bubbles are evaluated based on the diameters measured by both methods. Experiments are conducted for several mass flow rates of dissolved gas and of air bubbles entrained in the upstream of the decompression nozzle to examine effects of the entrained bubbles on bubble diameter. As a result, the following conclusions are obtained: (1) Diameter distribution of micro bubbles can be accurately measured for a wide range of diameter by using PDA and the image processing method. (2) The mean diameter of micro-bubbles generated by gasification of dissolved gas is smaller than that generated by breakup of air bubbles entrained in the upstream of the decompression nozzle. (3) The mean bubble diameter increases with the entrainment of air bubbles in the upstream of the decompression nozzle at a constant mass flow rate of dissolved gas.

  4. Measurement of micro Bubbles generated by a pressurized dissolution method

    International Nuclear Information System (INIS)

    Hosokawa, S; Tanaka, K; Tomiyama, A; Maeda, Y; Yamaguchi, S; Ito, Y

    2009-01-01

    Diameters of micro-bubbles are apt to range from about one mm to several-hundred mm, and therefore, it is difficult to measure a correct diameter distribution using a single measurement method. In this study, diameters of bubbles generated by a pressurized dissolution method are measured by using phase Doppler anemometry (PDA) and an image processing method, which is based on the Sobel filter and Hough transform. The diameter distribution and the Sauter mean diameter of micro bubbles are evaluated based on the diameters measured by both methods. Experiments are conducted for several mass flow rates of dissolved gas and of air bubbles entrained in the upstream of the decompression nozzle to examine effects of the entrained bubbles on bubble diameter. As a result, the following conclusions are obtained: (1) Diameter distribution of micro bubbles can be accurately measured for a wide range of diameter by using PDA and the image processing method. (2) The mean diameter of micro-bubbles generated by gasification of dissolved gas is smaller than that generated by breakup of air bubbles entrained in the upstream of the decompression nozzle. (3) The mean bubble diameter increases with the entrainment of air bubbles in the upstream of the decompression nozzle at a constant mass flow rate of dissolved gas.

  5. Effect of Hemifacial Spasm on Intraocular Pressure Measurement.

    Science.gov (United States)

    Cicik, Erdogan; Yildirim, Rengin; Arici, Ceyhun; Dikkaya, Funda; Arslan, Osman Sevki

    2018-01-01

    To evaluate the effect of hemifacial spasm (HFS) on intraocular pressure (IOP) measurement. Twenty-four consecutive patients with HFS and 25 age- and gender-matched randomly selected eyes of healthy volunteers underwent corneal pachymetry and IOP measurements using Goldmann applanation tonometer (GAT) and noncontact tonometer (NCT). IOP measurements were performed before (during HFS) and 2 weeks after Botox injections in HFS patients and in healthy volunteers without Botox injections. There was no statistical difference between involved eye side and uninvolved eye side of HFS patients in measured central corneal thickness. Similarly, no difference was found between involved eye side of HFS patients and controls. There were no statistically significant differences comparing IOP values before treatment and levels measured at 2 weeks of Botox injections, either with GAT ( p = 0.33, 0.11) or NCT ( p = 0.80, 0.43) devices in the involved eyes and uninvolved eyes of patients with HFS, respectively. There were also no significant differences in these parameters (GAT ( p = 0.63) and NCT ( p = 0.54)) in controls. Contractions in facial muscles may not lead to significant increase in IOP in HFS patients. This result may help clinical decision making in the treatment of glaucoma patients with HFS. This trial is registered with NCT03390803.

  6. Sonourethrography of anterior urethral strictures: assessment of length and degree

    International Nuclear Information System (INIS)

    Kim, Jong Chul; Jeong, Youn Sin

    1994-01-01

    We reviewed out experience of sonourethrography(SUG) in male anterior urethral strictures to correlate the stricture length and degree seen on SUG with those on urethroscopy, surgery or biopsy. During the recent 6 years,both the retrograde urethrography (RUG) and SUG were preformed in 50 occasions for 47 patients with anteriorurethral stricture, that were subsequently evaluated urethroscopically or at surgery. As a whole, the length of the stricture seen on SUG did not correlate very well with that seen on RGU (r2=0.71, p<0.005). Considering the data from the operation as the gold standard, SUG was more accurate than RUG in depicting the exact stricturelength (r2=0.97 and 0.75 respectively,p<0.005). The shorter the lesion, the more accurate the data obtained.Although SUG certainly identified periurethral tissue, it was not adequate in predicting the depth of spongiofibrosis compared with full-depth biopsies in 20 patients. In conclusion, SUG, a dynamic study, accurately defined the stricture site, number and calibre. When compared with RUG, SUG was more accurate in the measurement of stricture length and in the demonstration of periurethral tissue, making it a valuable method in the evaluation of patients with suspected anterior urethral strictures

  7. Neutron flux measurements in C-9 capsule pressure tube

    International Nuclear Information System (INIS)

    Barbos, D.; Roth, C. S.; Gugiu, D.; Preda, M.

    2001-01-01

    C-9 capsule is a fuel testing facility in which the testing consists of a daily cycle ranging between the limits 100% power to 50% power. C-9 in-pile section with sample holder an instrumentation are introduced in G-9 and G-10 experimental channels. The experimental fuel channel has a maximum value when the in-pile section (pressure tube) is in G-9 channel and minimum value in G-10 channel. In this paper the main goals are determination or measurements of: - axial thermal neutron flux distribution in C-9 pressure tube both in G-9 and G-10 channel; - ratio of maximum neutron flux value in G-9 and the same value in G-9 channel and the same value in G-10 channel; - neutron flux-spectrum. On the basis of axial neutron flux distribution measurements, the experimental fuel element in sample holder position in set. Both axial neutron flux distribution of thermal neutrons and neutron flux-spectrum were performed using multi- foil activation technique. Activation rates were obtained by absolute measurements of the induced activity using gamma spectroscopy methods. To determine the axial thermal neutron flux distribution in G-9 and G-10, Cu 100% wire was irradiated at the reactor power of 2 MW. Ratio between the two maximum values, in G-9 and G-10 channels, is 2.55. Multi-foil activation method was used for neutron flux spectrum measurements. The neutron spectra and flux were obtained from reaction rate measurements by means of SAND 2 code. To obtain gamma-ray spectra, a HPGe detector connected to a multichannel analyzer was used. The spectrometer is absolute efficiency calibrated. The foils were irradiated at 2 MW reactor power in previously determined maximum flux position resulted from wire measurements. This reaction rates were normalized for 10 MW reactor power. Neutron self shielding corrections for the activation foils were applied. The self-shielding corrections are computed using Monte Carlo simulation methods. The measured integral flux is 1.1·10 14 n/cm 2 s

  8. The value of pressure ulcer risk assessment and interface pressure measurements in patients: A nursing perspective

    NARCIS (Netherlands)

    J.T.M. Weststrate

    2005-01-01

    textabstractPressure sores in an intensive care unit 35 and related variables: a descriptive study Prevalence of pressure ulcers, risk factors 47 and the use of pressure-relieving mattresses in ICU patients The clinical relevance of the Waterlow 61 Pressure Sore Risk Scale in the ICU The

  9. New intraocular pressure measurement method using reflected pneumatic pressure from cornea deformed by air puff of ring-type nozzle.

    Science.gov (United States)

    Kim, Hyung Jin; Seo, Yeong Ho; Kim, Byeong Hee

    2017-01-01

    In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3-5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3-5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more.

  10. Context-aware patient guidance during blood pressure self-measurement

    DEFF Research Database (Denmark)

    Sandager, Puk; Lindahl, Camilla; Schlütter, Jacob Mørup

    2013-01-01

    The importance of accurate measurement of blood pressure in the screening and management of hypertension during pregnancy is well established. Blood pressure levels can be measured manually by healthcare staff or by using a blood pressure self-measurement device, either at home or in the clinic...... the blood pressure self-measurement process. Preliminary results indicate that such active and context-aware guidance leads to more reliable measurements by inhibiting non-adherent patient behavior...

  11. Recognition and Treatment of Nongonococcal Urethritis in Clinical Practice

    Science.gov (United States)

    Isiadinso, O. O. A.

    1980-01-01

    Nongonococcal urethritis is a relatively common disorder in sexually active individuals. The incidence is almost as high, if not higher, than gonorrhea. This syndrome may present with signs and symptoms indistinguishable from acute gonococcal urethritis. It is essential to differentiate the two diseases, as treatment protocols are different. Early recognition of nongonococcal urethritis and proper therapy will often lead to complete resolution and prevention of annoying complications. PMID:6999164

  12. Gaseous Multiplication factor measurements on low pressure ethylene

    International Nuclear Information System (INIS)

    Hevia Vives, Alberto

    2008-01-01

    The present investigation consists of a study of a Proportional Counter considered as a fundamental part of an Absolute Neutron Dosimeter developed for the Chilean Nuclear Energy Commission. The proportional counter consists of a Polyethylene Cathode of approximately 5 cm in diameter and an Anode consisting of a central wire of 5 μm in diameter. The proportional counter is biased at 650 V. The gas pressure ranges from 12 to 36 Torr of pure Ethylene. The work comes up as a need to obtain gas gain curves (Gas Multiplication Factors) for the proportional counter operated in the conditions as mentioned. This is a consequence of the scarcity of the existing information referred to Ethylene for the range of bias and gas pressure required in this case. Likewise, the research involved in this study contributed with useful information for the institution involved in the design and construction of the neutron dosimeter, as well as for the scientific community through the publication of this work. The results were obtained by using the above-mentioned Neutron Dosimeter but instead of using recoil protons by fast neutrons, the measurements were completed by directly using a 241 Am alpha particle source installed inside the dosimeter. The analysis of results as well as a detailed study of the pulse shapes provided by the proportional counter was performed by using the well-known MathCAD software. This software contains a text interface that includes symbolic and numeric calculations. Results of the research show that for the high Reduced Electric Fields ( Sa > 1500 Volts/cmTorr) used throughout the present work, Townsend law is still valid. This law states that the Multiplication Factors may be considered as dependent on the Reduced Electric Field instead of depending on the bias and gas pressure separately

  13. Student measurement of blood pressure using a simulator arm compared with a live subject's arm.

    Science.gov (United States)

    Lee, Jennifer J; Sobieraj, Diana M; Kuti, Effie L

    2010-06-15

    To compare accuracy of blood pressure measurements using a live subject and a simulator arm, and to determine students' preferences regarding measurement. This was a crossover study comparing blood pressure measurements from a live subject and a simulator arm. Students completed an anonymous survey instrument defining opinions on ease of measurement. Fifty-seven students completed blood pressure measurements on live subjects while 72 students completed blood pressure measurements using the simulator arm. There were no significant systematic differences between the 2 measurement techniques. Systolic blood pressure measurements from a live subject arm were less likely to be within 4 mm Hg compared with measurements of a simulator arm. Diastolic blood pressure measurements were not significantly different between the 2 techniques. Accuracy of student measurement of blood pressure using a simulator arm was similar to the accuracy with a live subject. There was no difference in students' preferences regarding measurement techniques.

  14. Non-Invasive Measurement of Intracranial Pressure Pulsation using Ultrasound

    Science.gov (United States)

    Ueno, Toshiaki; Ballard, R. E.; Yost, W. T.; Hargens, A. R.

    1997-01-01

    Exposure to microgravity causes a cephalad fluid shift which may elevate intracranial pressure (ICP). Elevation in ICP may affect cerebral hemodynamics in astronauts during space flight. ICP is, however, a difficult parameter to measure due to the invasiveness of currently available techniques. We already reported our development of a non-invasive ultrasound device for measurement of ICP. We recently modified the device so that we might reproducibly estimate ICP changes in association with cardiac cycles. In the first experiment, we measured changes in cranial distance with the ultrasound device in cadavera while changing ICP by infusing saline into the lateral ventricle. In the second experiment, we measured changes in cranial distance in five healthy volunteers while placing them in 60 deg, 30 deg head-up tilt, supine, and 10 deg head-down tilt position. In the cadaver study, fast Fourier transformation revealed that cranial pulsation is clearly associated with ICP pulsation. The ratio of cranial distance and ICP pulsation is 1.3microns/mmHg. In the tilting study, the magnitudes of cranial pulsation are linearly correlated to tilt angles (r=0.87). The ultrasound device has sufficient sensitivity to detect cranial pulsation in association with cardiac cycles. By analyzing the magnitude of cranial pulsation, estimates of ICP during space flight are possible.

  15. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Directory of Open Access Journals (Sweden)

    Paschalis EI

    2014-01-01

    Full Text Available Eleftherios I Paschalis,* Fabiano Cade,* Samir Melki, Louis R Pasquale, Claes H Dohlman, Joseph B CiolinoMassachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA*These authors contributed equally to this workPurpose: To present an autonomous intraocular pressure (IOP measurement technique using a wireless implantable transducer (WIT and a motion sensor.Methods: The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline IOP.Results: On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg and mean vehicle IOP (13.27±2.1 mmHg (P=0.45, suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001, and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001. Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001. Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute, during which the IOP is not expected to change.Conclusion: IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.Keywords: IOP, pressure transducer, wireless, MEMS, implant, intraocular

  16. Adenocarcinoma arising in female urethral diverticulum

    International Nuclear Information System (INIS)

    Patanaphan, V.; Prempree, T.; Sewchand, W.; Hafiz, M.A.; Jaiwatana, J.

    1983-01-01

    Cancer arising from a female urethral diverticulum is rare, and because of its rarity, a review of the medical literature reveals significant nonuniformity in its management. We report an additional 2 cases of this disease, one of which has an even rarer feature of being mucin-producing. The management of our 2 cases is presented in detail and in line with the management of female urethral cancer. From our extensive literature search, diverticulectomy alone showed poor results with the highest rate of recurrence (67%). Extensive surgery, either in the form of cystourethrectomy or anterior exenteration, offered results comparable with those of combined therapy (diverticulectomy and full course of irradiation for early cases; preoperative irradiation followed by cystourethrectomy for late cases). Individualization of radiation treatment and cooperative effort between urologist and radiation oncologist are essential if best results are to be achieved

  17. Late presentation of posterior urethral valves.

    Science.gov (United States)

    Jalbani, Imran Khan; Biyabani, Syed Raziuddin

    2014-05-01

    Presence of posterior urethral valves (PUV) is the most common cause of urinary tract obstruction in the male neonate. Late presentation occurs in 10% of cases. We present a case of PUVs in an adult male who presented with history of obstructive lower urinary tract symptoms and hematuria. On evaluation, he was found to have raised serum creatinine level. A voiding cystourethrogram (VCUG) could not be completely performed because of narrowing in the posterior urethra. A rigid urethrocystoscopy was performed at which he was found to have type-I posterior urethral valve which were fulgurated. A repeat uroflowmetry revealed maximum flow rate of 12 ml/second. This case highlights that PUVs is not solely a disease of infancy but may also present late. VCUG is the radiological investigation of choice but the diagnosis may be missed. A urethrocystoscopy is advised if there is a high index of suspicion.

  18. Asymptomatic urethral lymphogranuloma venereum: a case report.

    Science.gov (United States)

    Charest, Louise; Fafard, Judith; Greenwald, Zoë R

    2018-07-01

    Since 2003, there has been a resurgence of lymphogranuloma venereum (LGV), a variant of Chlamydia trachomatis (CT), among men who have sex with men (MSM) in several urban areas of Europe and North America. LGV infection occurs most often at anal sites causing proctitis. Urethral and oropharyngeal infections are rare. In Quebec, LGV incidence has been increasing exponentially in recent years and the current guidelines support systematic LGV genotype testing among anorectal CT-positive samples only. This case report describes a patient with a urethral LGV infection, remarkable due to its prolonged asymptomatic development prior to the manifestation of an inguinal bubo. Physicians should be vigilant of potential cases of LGV and forward CT-positive samples occurring among individuals with LGV risk factors for genotype testing.

  19. Pressure drop measurements in LMFBR wire wrapped blanket assemblies

    International Nuclear Information System (INIS)

    Chiu, C.; Hawley, J.; Rohsenow, W.M.; Todreas, N.E.

    1977-07-01

    In this experiment, measurements of subchannel static pressure for an interior and edge subchannel were taken at two elevations in two wire-wrapped 61-pin bundles. One of the bundles has geometric characteristics of P/D = 1.067 and H/D = 8.0 (4 inch lead length and 0.501 inch rod diameter) and the other bundle has geometric characteristics of P/D = 1.067 and H/D = 4.0 (2 inch lead length and 0.501 inch rod diameter). The bundle average friction factors as well as the local subchannel friction factors for both interior and edge subchannels were determined from the experimental static pressure data. The average subchannel flow rates for both edge and interior subchannels were determined in a separate experiment. Results show that two correlations suggested by Rehme and Novendstern for the bundle average friction factor cannot predict the data within the range of experimental error. The bundle average friction factors for both bundles under test were underestimated by Rehme's correlation and overestimated by Novendstern's correlation. The results of the local subchannel friction factors indicate the effect of the wire lead length is more pronounced in the interior subchannel friction factor than in the edge subchannel friction factor. As the wire wrap lead length decreases, both interior and edge subchannel friction factors increase

  20. Pressure drop measurements in LMFBR wire wrapped blanket assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, C.; Hawley, J.; Rohsenow, W.M.; Todreas, N.E.

    1977-07-01

    In this experiment, measurements of subchannel static pressure for an interior and edge subchannel were taken at two elevations in two wire-wrapped 61-pin bundles. One of the bundles has geometric characteristics of P/D = 1.067 and H/D = 8.0 (4 inch lead length and 0.501 inch rod diameter) and the other bundle has geometric characteristics of P/D = 1.067 and H/D = 4.0 (2 inch lead length and 0.501 inch rod diameter). The bundle average friction factors as well as the local subchannel friction factors for both interior and edge subchannels were determined from the experimental static pressure data. The average subchannel flow rates for both edge and interior subchannels were determined in a separate experiment. Results show that two correlations suggested by Rehme and Novendstern for the bundle average friction factor cannot predict the data within the range of experimental error. The bundle average friction factors for both bundles under test were underestimated by Rehme's correlation and overestimated by Novendstern's correlation. The results of the local subchannel friction factors indicate the effect of the wire lead length is more pronounced in the interior subchannel friction factor than in the edge subchannel friction factor. As the wire wrap lead length decreases, both interior and edge subchannel friction factors increase.

  1. Stress Rupture Life Reliability Measures for Composite Overwrapped Pressure Vessels

    Science.gov (United States)

    Murthy, Pappu L. N.; Thesken, John C.; Phoenix, S. Leigh; Grimes-Ledesma, Lorie

    2007-01-01

    Composite Overwrapped Pressure Vessels (COPVs) are often used for storing pressurant gases onboard spacecraft. Kevlar (DuPont), glass, carbon and other more recent fibers have all been used as overwraps. Due to the fact that overwraps are subjected to sustained loads for an extended period during a mission, stress rupture failure is a major concern. It is therefore important to ascertain the reliability of these vessels by analysis, since the testing of each flight design cannot be completed on a practical time scale. The present paper examines specifically a Weibull statistics based stress rupture model and considers the various uncertainties associated with the model parameters. The paper also examines several reliability estimate measures that would be of use for the purpose of recertification and for qualifying flight worthiness of these vessels. Specifically, deterministic values for a point estimate, mean estimate and 90/95 percent confidence estimates of the reliability are all examined for a typical flight quality vessel under constant stress. The mean and the 90/95 percent confidence estimates are computed using Monte-Carlo simulation techniques by assuming distribution statistics of model parameters based also on simulation and on the available data, especially the sample sizes represented in the data. The data for the stress rupture model are obtained from the Lawrence Livermore National Laboratories (LLNL) stress rupture testing program, carried out for the past 35 years. Deterministic as well as probabilistic sensitivities are examined.

  2. Posterior urethral polyps and review of literature

    Directory of Open Access Journals (Sweden)

    Prashant Jain

    2007-01-01

    Full Text Available Urethral polyp is a rare finding in young children. Fibroepithelial polyps of the urethra are usually diagnosed during the first decade of life. They present with obstruction, voiding dysfunction and hematuria. They can be associated with other congenital urinary tract anomalies. They are usually benign fibroepithelial lesions with no tendency to recur and are treated by surgical ablation, fulguration or laser therapy.

  3. Calculi in a Female Urethral Diverticulum

    Directory of Open Access Journals (Sweden)

    Ji Sung Shim

    2011-03-01

    Full Text Available Urinary stones are rarely seen in the urethra and are usually encountered in men with urethral stricture or diverticulum. The case of a 52-year-old woman presented, who consulted for weak stream associated with repeated urinary infections. The diverticulum was approached via vaginal route and the extraction was successful. The patient has been well, with no dysuria, dyspareunia, incontinence for 3-month follow-ups.

  4. Polypoidal Intestinal Metaplasia and Dysplasia of the External Urethral Meatus

    Directory of Open Access Journals (Sweden)

    Mary Mathew

    2012-01-01

    Full Text Available Urethral mucosa with intestinal metaplasia and dysplasia is a rare occurrence. To date only a single case has been reported in a male with long-standing urethral stricture. We present a 33-year-old female with polypoid intestinal metaplasia and dysplasia of the external urethral meatus in the absence of an inciting factor. Intestinal metaplasia of the urethral mucosa may undergo dysplasia, emphasizing the necessity of a high degree of clinical suspicion and vigilant pathological examination of these lesions.

  5. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Science.gov (United States)

    Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B

    2014-01-01

    Purpose To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. Methods The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. Results On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. Conclusion IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results. PMID:24531415

  6. Reliable intraocular pressure measurement using automated radio-wave telemetry.

    Science.gov (United States)

    Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B

    2014-01-01

    To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.

  7. Balloon catheter dilatation of benign urethral strictures

    International Nuclear Information System (INIS)

    Perini, L.; Cavallo, A.; Perin, B.; Bighi, G.

    1988-01-01

    The authors report their experience of benign urethral stricture dilatation by balloon catheter in 11 male patients. Ten posterior and 2 anterior urethral strictures were treated; in 1 patients several narrowings coexisted at various levels. Etiology was inflammatory in 4 cases, iatrogen in 3, post-traumatic in 2, and equivocal in 2. The patients were studied both before and soon after dilatation by means of retrograde and voiding cystourethrogram and uroflowgraphy; the follow-up (2-14 months) was performed by urodynamic alone. In all cases, dilatation was followed by the restoration of urethral gauge, together with prompt functional improvement of urodynamic parameters. The latter result subsisted in time in 9 patients. In 2 cases recurrences were observed demonstrated at once by clinics and urodynamics. Both lesions were successfully re-treated. Neither early not late complication occurred. In spite of the limited material, the valuable results obtained, together with the absence of complications, the peculiar morphology of recurrences, and the chance of repeating it make the procedure advisable as a valid alternative to conventional techniques for these pathologies

  8. Urethral Foreign Body: A Case report

    Directory of Open Access Journals (Sweden)

    Ozgur Enginyurt

    2013-03-01

    Full Text Available Urethral insertion of foreign bodies is not very common. It is often associated with psychological problems and sexual alerts. In men due to the longer urethra this situation remains generally limited to the urethra, in women due to the short urethra foreign body can pass to the bladder. 40 years old, mentally retarded male patient was admitted to the emergency department with a complaint of urethrorrhagia. Physical examination revealed needle like structure in the urethra. The patient was taken into the operating room and under general anestesia by using cysto panendoscopy the foreign body has been identified as an old syringe needle, foreign body was removed with the help of forceps. Endoscopic methods should be utilized for the realization of the diagnosis and treatment of urethral foreign bodies. Foreign body in the urethra is usually encountered in patients with psychiatric disorders. For this reason, a detailed psychiatric evaluation is important in patients with urethral foreign bodies. [J Contemp Med 2013; 3(1.000: 62-65

  9. Concomitant urethral triplication, bladder, and colon duplication.

    Science.gov (United States)

    Tourchi, Ali; Kajbafzadeh, Abdol-Mohammad; Khakpour, Mahshid; Mohammadi Nejad, Payam; Mousavian, Amir-Abbas; Kalantary, Mahdi

    2012-02-01

    The concomitant presence of urethral triplication and caudal duplication is extremely rare with no previous reported cases. We report a case of urethral triplication associated with bladder, sigmoid, and rectum duplication. The patient was initially referred with a history of fecaluria and recurrent urinary tract infection. Physical examination revealed 2 meatal opening on the glans penis. Further investigation revealed three distinct urinary streams, two terminating on the glans penis, and one in the rectum in voiding cystourethrography and retrograde urethrography. Computed tomography demonstrated the bladder divided into two compartments by a complete sagittal septum. The patient was managed by the excision of the rectal ending urethra and removal of the bladder sagittal septum during which, two sigmoidal and rectal segments (the right one filled with fecal) were revealed. The right sigmoid and rectum was resected. The two ventral urethras were kept intact. The postoperative course was uneventful. At his 4 month readmission for colostomy closure, the patient reported good urethral voiding with no complication and recurrence of urinary tract infection and the colostomy was closed with no major complication.

  10. Non-Invasive Measurement of Pulsatile Intracranial Pressures Using Ultrasound

    Science.gov (United States)

    Ueno, Toshiaki; Ballard, Richard E.; Shuer, Lawrence M.; Cantrell, John H.; Cantrell, John H.; Hargens, Alan R.

    1997-01-01

    Early detection of elevated intracranial pressure (ICP) will aid clinical decision-making for head trauma, brain tumor and other cerebrovascular diseases. Conventional methods, however, require surgical procedures which take time and are accompanied by increased risk of infection. Accordingly we have developed and refined a new ultrasound device to measure skull movements which are known to occur in conjunction with altered ICP. The principle of this device is based upon pulse phase locked loop (PPLL), which enables us to detect changes in distance on the order of microns between an ultrasound transducer on one side of the skull and the opposite inner surface of the cranium. The present study was designed to verify this measurement technique in cadavera. Transcranial distance was increased in steps of 10 mmHg from zero to 50 mmHg by saline infusion into the lateral ventricle of two cadavera. In separate experiments, pulsations of ICP with the amplitudes of zero to 2 mmHg were generated by rhythmic injections of saline using a syringe. When the ICP was stepwise increased from zero to 50 mmHg, transcranial distance increased in proportion with the ICP increase (y=12 x - 76, r=0.938), where y is changes in transcranial distance in microns and x is ICP in mmHg. In the data recorded while ICP pulsations were generated, fast Fourier transform analysis demonstrated that cranial pulsations were clearly associated with ICP pulsations. The results indicate that changes in transcranial distance is linearly correlated with those in ICP, and also that the PPLL device has sufficient sensitivity to detect transcranial pulsations which occur in association with the cardiac cycle. By analyzing the magnitude of cranial pulsations, we may be able to estimate the pressure-volume index in the cranium. As a result, estimates of intracranial compliance may be possible by using the PPLL device. Further studies are necessary in normal subjects and patients.

  11. The Efficacy of Bulbar Urethral Mobilization for Anastomotic Anterior Urethroplasty in a Case With Recurrent Anterior Urethral Stricture

    OpenAIRE

    Fukui, Shinji; Aoki, Katsuya; Kaneko, Yoshiteru; Samma, Shoji; Fujimoto, Kiyohide

    2014-01-01

    A 2-month-old boy was diagnosed with febrile urinary tract infection. Voiding cystourethrography showed bulbar and anterior urethral strictures, and endoscopic internal urethrotomy was performed. He developed febrile urinary tract infection again and revealed the recurrence of the anterior urethral stricture. Consequently, endoscopic internal urethrotomy was performed 4 times. Because the anterior urethral stricture had not improved, he was referred to us. Anterior urethroplasty was performed...

  12. Evaluation of the Automatic Density Compensation for Pressurizer Level Measurement

    International Nuclear Information System (INIS)

    Jeong, Insoo; Min, Seohong; Ahn, Myunghoon

    2014-01-01

    When using two transmitters, it is difficult for the operators to identify the correct level of the pressurizer (PZR) upon failure of one of the two transmitters. For this reason, Korean Utility Requirements Document (KURD) requires that the operators to use three independent level indicators. Two hot calibrated transmitters and one cold calibrated transmitter compose PZR level transmitters in APR1400. In this paper, the deviation between cold calibration and hot calibration is evaluated, and the application of compensated PZR level measurement and uncompen-sated PZR level measurement during the normal operation of APR1400 are introduced. The PZR level signals for APR1400 come in three channels. To satisfy the KURD requirements for PZR level measurement, and at the same time to accomplish correction design and implementation, applicability and differences between hot calibration and cold calibration, compensated level and uncompensated level were evaluated as follows: For proper indication of PZR levels under normal operating condition, two of the three transmitters went through hot calibration and the remaining one transmitter went through cold calibration. This was to allow indicating entire regions of PZR regardless of the plant operation modes. For automatic density compensation per KURD requirements, the algorithm of the density compensated PZR level implemented in the DCS controller and PRV logic is adopted as a signal validation method

  13. The Efficacy of Bulbar Urethral Mobilization for Anastomotic Anterior Urethroplasty in a Case With Recurrent Anterior Urethral Stricture.

    Science.gov (United States)

    Fukui, Shinji; Aoki, Katsuya; Kaneko, Yoshiteru; Samma, Shoji; Fujimoto, Kiyohide

    2014-05-01

    A 2-month-old boy was diagnosed with febrile urinary tract infection. Voiding cystourethrography showed bulbar and anterior urethral strictures, and endoscopic internal urethrotomy was performed. He developed febrile urinary tract infection again and revealed the recurrence of the anterior urethral stricture. Consequently, endoscopic internal urethrotomy was performed 4 times. Because the anterior urethral stricture had not improved, he was referred to us. Anterior urethroplasty was performed when he was 5 years. After excision of the scarred portions of the urethra, the defect of the urethra was 20 mm. Transperineal bulbar urethral mobilization was performed, and a single-stage end-to-end anterior urethroplasty without tension could be performed simultaneously.

  14. Experimental measurements of static pressure and pressure drop in a duct enclosing a seven wire-wrapped rod bundle

    International Nuclear Information System (INIS)

    Graca, M.C.; Ballve, H.; Fernandez y Fernandez, E.; Carajilescov, P.

    1981-01-01

    The friction factor and the static pressure distributions, in the axial and transversal directions, in the wall of the hexagonal duct, enclosing a seven wire-wrapped rod bundle, were experimentally measured, using an air opened loop. The Reynolds numbers are the range 10 3 - 5x10 4 . The friction factors are compared to existing correlations. The static pressure distributions show that the static pressure is not hydrostatic in the cross section of the flow. (Author) [pt

  15. Liquid crystalline fiber optic colorimeter for hydrostatic pressure measurement

    Science.gov (United States)

    Wolinski, Tomasz R.; Bajdecki, Waldemar K.; Domanski, Andrzej W.; Karpierz, Miroslaw A.; Konopka, Witold; Nasilowski, T.; Sierakowski, Marek W.; Swillo, Marcin; Dabrowski, Roman S.; Nowinowski-Kruszelnicki, Edward; Wasowski, Janusz

    2001-08-01

    This paper presents results of tests performed on a fiber optic system of liquid crystalline transducer for hydrostatic pressure monitoring based on properties of colorimetry. The system employs pressure-induced deformations occurring in liquid crystalline (LC) cells configured in a homogeneous Frederiks geometry. The sensor is compared of a round LC cell placed inside a specially designed pressure chamber. As a light source we used a typical diode operating at red wavelength and modulated using standard techniques. The pressure transducer was connected to a computer with a specially designed interface built on the bas of advanced ADAM modules. Results indicate that the system offers high response to pressure with reduced temperature sensitivity and, depending on the LC cell used, can be adjusted for monitoring of low hydrostatic pressures up to 6 MPa. These studies have demonstrated the feasibility of fiber optic liquid crystal colorimeter for hydrostatic pressure sensing specially dedicated to pipe- lines, mining instrumentation, and process-control technologies.

  16. Blood pressure measurement in epidemiological investigations in teenagers

    International Nuclear Information System (INIS)

    Coppieters, Yves; Parent, Florence; Berghmans, Luc; Godin, Isabelle; Leveque, Alain

    2001-01-01

    Background: The use of sphygmomanometers may lead to problems in investigations on health of young people. The purpose of this paper is to present the validation of the blood pressure (BP) collected during the survey 'Youth Heart Health' in Hainaut by using second sample of young people in Hainaut for which BP was measured by a manual taking of tension and by an electronic device. Methods: Validation was done with a control sample of 343 young with five successive BP measures: twice with the mercury sphygmomanometer and three with DXL. We compared the manual and the electronic measures in order to study the correlation between the two methods. The control sample was used in order to compare the BP measurements with the results of the survey on the health of young people in Hainaut. Results: The differences between manual systolic BP and Dinamap measures are significant (differences in averages 3.6 mmHg; d.s. 7.8; 95% CI: 2.8-4.4 mmHg; p < 0.001) and the regression coefficient is -0.015. Diastolic BP is significantly higher with the manual method than with Dinamap (differences in means: 8.2 mmHg; d.s. 7.0; 95% CI: 7.4-8.9 mmHg; p < 0.001) and the coefficient of regression is 0.096. We observe a difference in BP between the general survey and the control group (10.3 mmHg for systolic manual control and of 10.9 mmHg for systolic electronic control; 3.3 mmHg for diastolic manual control and of 11.5 mmHg for diastolic electronic control). Conclusions: The values of BP of the 'Youth Heart Health' are significantly higher. These observations indicate the difficulties in the choice of the tool for measurements of BP in epidemiological investigations in the teenagers. In order to decrease skews of observations in the measurement of BP, it is recommended to use a valid electronic instrument. Dinamap XL is an instrument of choice in such studies of young people. Environmental and organisational factors may also explain the observed difference, which means that survey

  17. Endoscopic PIV measurements in a low pressure turbine rig

    Energy Technology Data Exchange (ETDEWEB)

    Kegalj, Martin; Schiffer, Heinz-Peter [Technische Universitaet Darmstadt (Germany). Department of Gas Turbines and Aerospace Propulsion

    2009-10-15

    Particle-Image-Velocimetry (PIV) is a useful way to acquire information about the flow in turbomachinery. Several premises have to be fulfilled to achieve high-quality data, for example, optical access, low vibrations and low reflections. However, not all test facilities comply with these requirements. If there is no optical access to the test area, measurements cannot be performed. The use of borescopic optics is a possible solution to this issue, as the access required is very small. Several different techniques can be used to measure the three components of the velocity vector, one of which is Stereo-PIV. These techniques require either large optical access from several viewing angles or highly complex setups. Orthogonal light sheet orientations in combination with borescopic optics using Planar-PIV can deliver sufficient information about the flow. This study will show the feasibility of such an approach in an enclosed test area, such as the interblade space in a Low-Pressure-Turbine-Rig. The results from PIV will be compared with data collected with conventional techniques, such as the Five-Hole-Probe and the 2-component Hot-Wire-Anemometry. An analysis of time- and phase-averaged data will be performed. (orig.)

  18. Time-averaged second-order pressure and velocity measurements in a pressurized oscillating flow prime mover

    Energy Technology Data Exchange (ETDEWEB)

    Paridaens, Richard [DynFluid, Arts et Metiers, 151 boulevard de l' Hopital, Paris (France); Kouidri, Smaine [LIMSI-CNRS, Orsay Cedex (France)

    2016-11-15

    Nonlinear phenomena in oscillating flow devices cause the appearance of a relatively minor secondary flow known as acoustic streaming, which is superimposed on the primary oscillating flow. Knowledge of control parameters, such as the time-averaged second-order velocity and pressure, would elucidate the non-linear phenomena responsible for this part of the decrease in the system's energetic efficiency. This paper focuses on the characterization of a travelling wave oscillating flow engine by measuring the time-averaged second order pressure and velocity. Laser Doppler velocimetry technique was used to measure the time-averaged second-order velocity. As streaming is a second-order phenomenon, its measurement requires specific settings especially in a pressurized device. Difficulties in obtaining the proper settings are highlighted in this study. The experiments were performed for mean pressures varying from 10 bars to 22 bars. Non-linear effect does not constantly increase with pressure.

  19. Time response measurements of pressure sensors using pink noise technique

    International Nuclear Information System (INIS)

    Pereira, Iraci Martinez; Santos, Roberto Carlos dos

    2009-01-01

    This work presents an experimental setup for Pink Noise method application on pressure transmitters' response times. The Pink Noise method consists on injecting artificial pressure noise into the pressure transmitter. The artificial pressure noise is generated using a current-to-pressure (I-to-P) converter, which is driven by a random noise signal generator. The output pressure transmitter noise is then analyzed using conventional Noise Analysis Technique. Noise signals may be interpreted using spectral techniques or empirical time series models. The frequency domain method consists of evaluating the Power Spectral Density (PSD) function. The information needed for time constant estimation can be obtained by fitting an all-pole transfer function to this power spectral density. (author)

  20. Optical measurement of acoustic radiation pressure of the near-field acoustic levitation through transparent object

    OpenAIRE

    Nakamura, Satoshi; Furusawa, Toshiaki; Sasao, Yasuhiro; Katsura, Kogure; Naoki, Kondo

    2013-01-01

    It is known that macroscopic objects can be levitated for few to several hundred micrometers by near-field acoustic field and this phenomenon is called near-field acoustic levitation (NFAL). Although there are various experiments conducted to measure integrated acoustic pressure on the object surface, up to now there was no direct method to measure pressure distribution. In this study we measured the acoustic radiation pressure of the near-field acoustic levitation via pressure-sensitive paint.

  1. Design and Development of a Pressure Transmitter Using Modified Inductance Measuring Network and Bellow Sensor

    OpenAIRE

    Venkata Lakshmi Narayana K.; Bhujanga Rao A.

    2013-01-01

    In this paper, a pressure transmitter using a modified op-amp based network for inductance measurement using a bellow as sensor has been proposed to measure the pressure and to convert pressure changes in to an electrical current which can be transmitted to a remote indicator. The change in inductance due to change in pressure is measured by an improved modified operational amplifier based network. The proposed network permits offset inductance compensation of sensing coil and also minimizes ...

  2. Conception and preliminary evaluation of an optical fibre sensor for simultaneous measurement of pressure and temperature

    International Nuclear Information System (INIS)

    Bremer, K; Moss, B; Leen, G; Mueller, I; Lewis, E; Lochmann, S

    2009-01-01

    This paper presents a novel concept of simultaneously measuring pressure and temperature using a silica optical fibre extrinsic Fabry-Perot interferometric (EFPI) pressure sensor incorporating a fibre Bragg grating (FBG), which is constructed entirely from fused-silica. The novel device is used to simultaneously provide accurate pressure and temperature readings at the point of measurement. Furthermore, the FBG temperature measurement is used to eliminate the temperature cross-sensitivity of the EFPI pressure sensor.

  3. Clinical presentation and treatment of urethral stricture: Experience ...

    African Journals Online (AJOL)

    O.N. Ekeke

    2016-08-23

    Aug 23, 2016 ... demography, aetiology, site, treatment and outcome of treatment of USD were collated and analyzed using. SPSS 20.0. Results: ... Eighty two patients (42.27%) had anterior urethral stricture; while 78 (40.20%) had posterior urethral strictures. ..... to leave a catheter and, if so, for what duration [34,4,35–37] in.

  4. Visual Internal Urethrotomy in the Management of Anterior Urethral ...

    African Journals Online (AJOL)

    Objective: Urethral stricture disease is common in our environment. The aim of this study is to report our experience with visual internal urethrotomy (VIU) in the management of this disease. Patients and Methods: Seventy male patients with a mean age of 30.6 years were treated for anterior urethral stricture by VIU at the Jos ...

  5. A descriptive study of urethral discharge among men in Fiji.

    Science.gov (United States)

    Gaunavinaka, Lavenia; Balak, Dashika; Varman, Sumanthla; Ram, Sharan; Graham, Stephen M

    2014-10-17

    Urethral discharge is a common presentation of sexually transmitted infection (STI) in men and known pathogens include Neisseria gonorrhoeae and Chlamydia trachomatis. There are no published data of the burden of urethral discharge among men in Fiji. To evaluate urethral discharge among men to determine the incidence, the frequency of recurrence and reported at-risk behaviour. We conducted a retrospective, descriptive study of clinical records of all men presenting with urethral discharge to two major reproductive health clinics. Data collected included self-reported at-risk behaviours, results of abnormal syphilis serology and antibiotics prescribed. The frequency of recurrence in the following 1-2 years of initial presentation was determined along with microbiological findings from urethral swab in this group. A total of 748 males presented with urethral discharge to the clinic in one year. This represents an incidence rate of at least 295 per 100,000 adult males per year in the study population. Within the next 1-2 years of the initial presentation, 102 (14%) of these re-presented out of which 42 had urethral swab taken for etiological diagnosis. The commonest isolate was Neisseria gonorrhoeae. Results of syphilis tests were available for 560 (75%) of patients and 29 (5%) were positive. Recurrence was not associated with self-reported at-risk behaviours. The incidence of urethral discharge among males in Fiji is very high and prevention strategies are urgently needed.

  6. Fiber types in the striated urethral and anal sphincters

    DEFF Research Database (Denmark)

    Schrøder, H D; Reske-Nielsen, E

    1983-01-01

    Seven normal human striated urethral and anal sphincters obtained by autopsy were examined using histochemical techniques. In both the urethral sphincter and the subcutaneous (s.c.) and superficial part of the anal sphincter a characteristic pattern with two populations of muscle fibers, abundant...

  7. Female Urethral Anomalies in Pediatric Age Group: Uncovered

    African Journals Online (AJOL)

    Urogenital sinus in females (ectopia of the external urethral opening in the urogenital sinus). All the variants of female hypospadias must be surgically corrected as transposition of the external opening of the urethra from the vagina on the perineum under the clitoris in chronic urethritis. The second case mentioned above.

  8. Urethritis due to corynebacterium striatum: An emerging germ.

    Science.gov (United States)

    Frikh, Mohammed; El Yaagoubi, Imad; Lemnouer, Abdelhay; Elouennass, Mostafa

    2015-01-01

    Corynedbacterium striatum (CS) is a Gram-positive coryneform bacillus that is part of mucous and skin flora. It has been considered as a causative agent of many infections in intensive care, neurology, traumatology and urology, but was never implicated in non-gonococcal urethritis. We report the case of a nosocomial urethritis due to Corynebacterium striatum following resection of an intrameatus condyloma.

  9. Transurethral incision of urethral diverticulum in the female

    DEFF Research Database (Denmark)

    Miskowiak, J; Honnens de Lichtenberg, M

    1989-01-01

    A new technique of transurethral incision of urethral diverticulum was successfully used in two women. The method described is safe, simple and shortens operating time.......A new technique of transurethral incision of urethral diverticulum was successfully used in two women. The method described is safe, simple and shortens operating time....

  10. Gonococcal Conjunctivitis Despite Successful Treatment of Male Urethritis Syndrome.

    Science.gov (United States)

    Peters, Remco P H; Verweij, Stephan P; McIntyre, James A; Schaftenaar, Erik

    2016-02-01

    We report a case of progressive, cephalosporin-susceptible, Neisseria gonorrhoeae conjunctivitis despite successful treatment of male urethritis syndrome. We hypothesize that conjunctival infection progressed due to insufficient penetration of cefixime and azithromycin and point out that extragenital infection and male urethritis may not be cured simultaneously in settings where the syndromic approach is used.

  11. Treatment of Acute Uncomplicated Gonococcal Urethritis in Males by Rosoxacin

    Directory of Open Access Journals (Sweden)

    A N Tiwari

    1986-01-01

    Full Text Available Twenty eight male patients with acute gonococcal, urethritis were treated, with rosoxacin 300 mg capsule, (Eradacil as a single- dose oral therapy. Twenty six patients were cured, while two patients did not improve. Four patients developed post-gonococcal urethritis (PGU.

  12. Congenital urethral polyps: a report of two cases

    International Nuclear Information System (INIS)

    Cano, D.; Vivas, I.; Torres, E.; Garcia, L.; Fernandez-Villa, T.

    1999-01-01

    Congenital urethral polyps are uncommon lesions, very few cases of which have been previously reported in the literature. We present two cases of congenital urethral polyps in children, describing the clinical and radiological features and the diagnostic method employed, as well as reviewing the literature. (Author) 6 refs

  13. Original article Urethral Stricture and HIV: Unusual Presentations ...

    African Journals Online (AJOL)

    mn

    cause of urethral stricture in this series was traumatic injury The other important cause was post-inflammatory (after gonococcal urethritis) with HIV co-infection. These patients posed a challenge due to our lack of experience and the absence of literature guidelines on the optimal management. The first unusual feature in the ...

  14. Epidemiology of urethral stricture at Tygerberg Hospital | Steenkamp ...

    African Journals Online (AJOL)

    Over a 12-month period, 120 consecutive male patients with confirmed urethral stricture were prospectively studied with regard to the epidemiology of the disease. Specific urethritis is the main aetiological factor (45%) and internal and external trauma account for an alarming 38,3% of cases. The prevalence is highest ...

  15. Results of surgical excision of urethral prolapse in symptomatic patients.

    Science.gov (United States)

    Hall, Mary E; Oyesanya, Tola; Cameron, Anne P

    2017-11-01

    Here, we present the clinical presentation and surgical outcomes of women with symptomatic urethral prolapse presenting to our institution over 20 years, and seek to provide treatment recommendations for management of symptomatic urethral prolapse and caruncle. A retrospective review of medical records from female patients who underwent surgery for symptomatic urethral prolapse from June 1995 to August 2015 was performed. Surgical technique consisted of a four-quadrant excisional approach for repair of urethral prolapse. A total of 26 patients were identified with a mean age of 38.8 years (range 3-81). The most common presentations were vaginal bleeding, hematuria, pain, and dysuria. All patients underwent surgical excision of urethral prolapse via a standard approach. Follow-up data was available in 24 patients. Six patients experienced temporary postoperative bleeding, and one patient required placement of a Foley catheter for tamponade. One patient experienced temporary postoperative urinary retention requiring Foley catheter placement. Three patients had visible recurrence of urethral prolapse, for which one later underwent re-excision. Surgical excision of urethral prolapse is a reasonable treatment option in patients who have tried conservative management without relief, as well as in those who present with severe symptoms. Possible complications following excision include postoperative bleeding and recurrence, and patients must be counseled accordingly. In this work, we propose a treatment algorithm for symptomatic urethral prolapse. © 2017 Wiley Periodicals, Inc.

  16. Direct vision internal urethrotomy in 459 urethral stricture patients at ...

    African Journals Online (AJOL)

    Four hundred and fifty nine patients seen with simple urethral strictures between 1990 and 1998 underwent direct vision urethrotomy.. The procedure was successful in 441 patients and failed in only 18 patients. Postoperative complications included fever in 31 patients, urethral bleeding in 14 and epididymitis in 17 patients.

  17. Direct vision internal urethrotomy in 459 urethral stricture patients at ...

    African Journals Online (AJOL)

    Keywords: Direct vision, internal, urethrotomy, urethral and stricture.;. Four hundred and fifty nine patients seen with simple urethral strictures between 1990 and 1998 underwent direct vision urethrotomy.. The procedure was successful in 441 patients and failed in only 18 patients. Postoperative complications included fever.

  18. A rare case of congenital Y-type urethral duplication

    Directory of Open Access Journals (Sweden)

    Charu Tiwari

    2015-11-01

    Full Text Available Duplication of urethra is a rare congenital anomaly. We report a case of Y-type of urethral duplication with the accessory urethra arising from posterior urethra and opening in the perineum. The orthotopic urethra was normal. The accessory urethral tract was cored, transfixed and divided. At 1 year of follow-up, the patient has no urinary complaints

  19. Posterior urethral valves: search for a diagnostic reference standard

    NARCIS (Netherlands)

    de Jong, Tom P. V. M.; Radmayr, Christian; Dik, Pieter; Chrzan, Rafal; Klijn, Aart J.; de Kort, Laetitia

    2008-01-01

    To test the agreement among pediatric urologists regarding endoscopic findings concerning posterior urethral valves. A total of 25 experienced pediatric urologic surgeons observed 11 video fragments of cystourethroscopy in boys. For most of these boys, a strong suspicion of urethral obstruction had

  20. Delayed primary realignment of posterior urethral rupture | Shittu ...

    African Journals Online (AJOL)

    The treatment of acute posterior urethral rupture is controversial. Twelve patients who presented with acute posterior urethral rupture over a five--year period were treated by delayed primary realignment of the injury. The technique of this procedure and the outcome are the subject of this presentation. Eight patients had ...

  1. Urethral Stricture as seen in Dar es Salaam, Tanzania.

    African Journals Online (AJOL)

    dell

    urethritis have increasingly been incriminated as a major etiological factor of inflammatory urethral stricture especially in the developed world. Organisms which fall in this group include. Ureaplasma (T-strain), Mycoplasma, Trichomonas vaginalis, Candida albicans, and Haemophilus vaginalis, Herpes simplex virus type II, ...

  2. Dorsolateral onlay urethroplasty for anterior urethral strictures by a unilateral urethral mobilization approach.

    Science.gov (United States)

    Singh, Bhupendra P; Pathak, Hemant R; Andankar, Mukund G

    2009-04-01

    For management of long segment anterior urethral stricture, dorsal onlay urethroplasty is currently the most favored single-stage procedure. Conventional dorsal onlay urethroplasty requires circumferential mobilization of the urethra, which might cause ischemia of the urethra in addition to chordee. To determine the feasibility and short-term outcomes of applying a dorsolateral free graft to treat anterior urethral stricture by unilateral urethral mobilization through a perineal approach. A prospective study from September 2005 to March 2008 in a tertiary care teaching hospital. Seventeen patients with long or multiple strictures of the anterior urethra were treated by a dorsolateral free buccal mucosa graft. The pendulous urethra was accessed by penile eversion through the perineal wound. The urethra was not separated from the corporal bodies on one side and was only mobilized from the midline on the ventral aspect to beyond the midline on the dorsal aspect. The urethra was opened in the dorsal midline over the stricture. The buccal mucosa graft was secured on the ventral tunica of the corporal bodies. Mean and median. After a follow-up of 12-30 months, one recurrence developed and 1 patient needed an internal urethrotomy. A unilateral urethral mobilization approach for dorsolateral free graft urethroplasty is feasible for panurethral strictures of any length with good short-term success.

  3. Single-Staged Improved Tubularized Preputial/Penile Skin Flap Urethroplasty for Obliterated Anterior Urethral Stricture: Long-Term Results.

    Science.gov (United States)

    Xue, Jing-Dong; Xie, Hong; Fu, Qiang; Feng, Chao; Guo, Hui; Xu, Yue-Min

    2016-01-01

    To present an improved tubularized flap (ITF) technique and report the outcome of single-stage urethroplasty using preputial/penile skin flaps (PSFs) for the treatment of obliterative anterior urethral strictures (AUSs). From January 2000 to June 2012, 42 cases of obliterative AUS (3-14 cm, mean 6.38 cm) with urethral plate unsalvageable were treated using PSF-ITF urethroplasty including longitudinal skin flap, circular island flap, L-flap, Q-flap. Patients were divided into 3 groups: pendulous urethral stricture (Group A), bulbar urethral stricture (Group B) and panurethral strictures (Group C). Patients were followed up by uroflowmetry, urethrography and ureteroscope when necessary. The mean follow-up in these patients was 65 months (range 36 months-15 years). The primary success rates at 3-year follow-up were 75, 75 and 60% for Groups A, B and C, respectively. The overall success rates were 85, 83 and 70% with the remedial measure of a single visual internal urethrotomy at 3-year follow-up. A total 60% of the patients in the study completed more than 5 years of follow-up with no additional recurrence. Improved tubularized preputial/PSF urethroplasty with relatively high overall satisfaction is a novel technique for treatment of AUS when there is inadequate urethral plate or obliterative defects. © 2016 S. Karger AG, Basel.

  4. The effect of penile urethral fat graft application on urethral angiogenesis.

    Science.gov (United States)

    Cakmak, M; Yazıcı, I; Boybeyi, O; Ayva, S; Aslan, M K; Senyucel, M F; Soyer, T

    2015-10-01

    Autologous fat grafts are rich in adipose-derived stem cells, providing optimal soft-tissue replacement and significant quantities of angiogenic growth factor. Although fat grafts (FG) are used in several clinical conditions, the use of FG in urethral repairs and the effects of FG to urethral repairs have not yet been reported. An experimental study was performed to evaluate the effect of FG on urethral angiogenesis and tissue growth factor (GF) levels. Sixteen Wistar albino, adult, male rats were allocated into two groups: the control group (CG) (n = 8) and the experiment group (EG) (n = 8). After anesthetization of all rats, 3-mm vertical incisions were made on the urethras, and then sutured with interrupted 5/0 vicryl sutures. The operations were performed under a stereo dissecting microscope under magnification (×20). In the CG, no additional procedure was performed. In the EG after the same surgical procedure, 1 mm(3) FG was removed from the inguinal region by sharp dissection with a knife. The grafts were trimmed to 1 × 1 mm dimensions on millimeter paper. The FGs were placed on the repaired urethras. The skin was then closed. Samples from urethral and penile skin were taken 21 days after surgery in both groups. Density and intensity of staining with vascular-endothelial GF (VEGF), VEGF-receptor, and endothelial-GF receptor (EGFR) in the endothelial and mesenchymal cells of the penile urethral vessels were immunohistochemically evaluated. Data obtained from immunohistochemical evaluations were analyzed with SPSS 15.0. The P-values lower than 0.05 were considered as significant. Density of VEGF staining was significantly decreased in the vascular endothelium of the EG compared to the CG (P factor levels, which is contrary to the literature data. Fat grafting has an immunohistochemical effect on the growth factor levels that are related to angiogenesis after urethral repair. It is difficult to make a firm conclusion about the role of fat grafting on urethral

  5. Congenital anterior urethral valves and diverticula: Diagnosis and management in six cases

    Directory of Open Access Journals (Sweden)

    Rawat Jiledar

    2009-01-01

    Full Text Available Background: Anterior urethral valves (AUVs are rare congenital anomalies causing lower urinary tract obstruction in children. Although they are referred to as valves, these obstructive structures often occur in the form of a diverticulum. The urethra in these cases shows saccular or bulbar dilatation known as anterior urethral diverticulum (AUD. They typically occur where there is a defect in the corpus spongiosum, leaving a thin-walled urethra. This segment of the urethra balloons out during voiding, simulating a mass that is sometimes visible along the ventral wall of the penis. The swelling is fluctuant and urine dribbles from the meatus on compression. The present study highlights the clinical approach in identifying the condition and its treatment options, especially for those, presenting with urethral diverticula. Materials and Methods: We have studied children with congenital anterior urethral valves and diverticula. Six patients of AUVs with diverticula were admitted during the period of 2000-2007 and were prospectively evaluated. The mean age of presentation was 16 months (15 days to 4 years. Straining at micturition and a palpable penile swelling were the most common presenting features. The diagnosis was established by voiding cystourethrogram (VCUG and supported by ultrasonography (USG. All patients were treated with single-stage open surgical excision except one who died preoperatively due to urosepsis. Initial lay opening of the penoscrotal urethra and delayed repair were done in one patient. Results: The surgical outcome was successful in all but one patient, who died of delayed presentation with severe back pressure changes, urinary ascitis and urosepsis. On long-term follow-up, all patients demonstrated good stream of urine. The renal functions were normal and the patients had no evidence of urinary infections. Conclusion: We propose that, the patients of AUVs, if not excessively delayed for treatment are otherwise well in terms

  6. Reliability of blood pressure measurement and cardiovascular risk prediction

    NARCIS (Netherlands)

    van der Hoeven, N.V.

    2016-01-01

    High blood pressure is one of the leading risk factors for cardiovascular disease, but difficult to reliably assess because there are many factors which can influence blood pressure including stress, exercise or illness. The first part of this thesis focuses on possible ways to improve the

  7. An instrument to measure differential pore pressures in deep ocean sediments: Pop-Up-Pore-Pressure-Instrument (PUPPI)

    International Nuclear Information System (INIS)

    Schultheiss, P.J.; McPhail, S.D.; Packwood, A.R.; Hart, B.

    1985-01-01

    A Pop-Up-Pore-Pressure-Instrument (PUPPI) has been developed to measure differential pore pressures in sediments. The differential pressure is the pressure above or below normal hydrostatic pressure at the depth of the measurement. It is designed to operate in water depths up to 6000 metres for periods of weeks or months, if required, and measures differential pore pressures at depths of up to 3 metres into the sediments with a resolution of 0.05 kPa. It is a free-fall device with a lance which penetrates the sediments. This lance and the ballast weight is disposed when the PUPPI is acoustically released from the sea floor. When combined with permeability and porosity values of deep-sea sediments the pore pressure measurements made using the PUPPI suggest advection velocities as low as 8.8 mm/yr. The mechanical, electrical and acoustic systems are described together with data obtained from both shallow and deep water trials. (author)

  8. Central venous pulse pressure analysis using an R-synchronized pressure measurement system.

    Science.gov (United States)

    Fujita, Yoshihisa; Hayashi, Daisuke; Wada, Shinya; Yoshioka, Naoki; Yasukawa, Takeshi; Pestel, Gunther

    2006-12-01

    The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7 mmHg and -0.9+/- 0.5 mmHg, respectively), with a mean pulse pressure of 3.4 mmHg. The difference between the mean CVP and CVP at end-diastole during expiration was 0.58+/- 0.81 mmHg. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.

  9. A comparison of blood pressure measurements in newborns.

    LENUS (Irish Health Repository)

    O'Shea, Joyce

    2012-02-01

    Blood pressure monitoring is an essential component of neonatal intensive care. We compared invasive and noninvasive (Dinamap, Marquette, and Dash) recordings in newborns and also noninvasive values obtained from upper and lower limbs. Infants\\' blood pressure was recorded every 6 hours for 72 hours using three noninvasive devices and compared with invasive readings taken simultaneously. Twenty-five babies were enrolled in the study, with birth weights of 560 to 4500 g and gestation 24 + 1 to 40 + 5 weeks. Three hundred thirty-two recordings were obtained. Comparison between invasive and noninvasive readings revealed that all three noninvasive monitors overread mean blood pressure. There was no significant difference between the cuff recordings obtained from the upper or lower limbs. All three noninvasive devices overestimated mean blood pressure values compared with invasive monitoring. Clinicians may be falsely reassured by noninvasive monitoring. Mean blood pressure values obtained from the upper and lower limb are similar.

  10. Development of a commercial Transducer for Measuring Pressure and Friction on the Model Die Surface

    DEFF Research Database (Denmark)

    Andersen, Claus Bo; Ravn, Bjarne Gottlieb; Wanheim, Tarras

    2001-01-01

    deflection in the tool causes incorrect shape of the final component. The dinemsions of the die-cavity have to be corrected taking into account die deflection due to the high internal pressure. The modelling material technique is suitable for measuring internal pressure, but so far only a transducer...... to measure normal pressure has been available....

  11. Large Cluster of Neisseria meningitidis Urethritis in Columbus, Ohio, 2015.

    Science.gov (United States)

    Bazan, Jose A; Turner, Abigail Norris; Kirkcaldy, Robert D; Retchless, Adam C; Kretz, Cecilia B; Briere, Elizabeth; Tzeng, Yih-Ling; Stephens, David S; Maierhofer, Courtney; Del Rio, Carlos; Abrams, A Jeanine; Trees, David L; Ervin, Melissa; Licon, Denisse B; Fields, Karen S; Roberts, Mysheika Williams; Dennison, Amanda; Wang, Xin

    2017-07-01

    Neisseria meningitidis (Nm) is a Gram-negative diplococcus that normally colonizes the nasopharynx and rarely infects the urogenital tract. On Gram stain of urethral exudates, Nm can be misidentified as the more common sexually transmitted pathogen Neisseria gonorrhoeae. In response to a large increase in cases of Nm urethritis identified among men presenting for screening at a sexually transmitted disease clinic in Columbus, Ohio, we investigated the epidemiologic characteristics of men with Nm urethritis and the molecular and phylogenetic characteristics of their Nm isolates. The study was conducted between 1 January and 18 November 2015. Seventy-five Nm urethritis cases were confirmed by biochemical and polymerase chain reaction testing. Men with Nm urethritis were a median age of 31 years (interquartile range [IQR] = 24-38) and had a median of 2 sex partners in the last 3 months (IQR = 1-3). Nm cases were predominantly black (81%) and heterosexual (99%). Most had urethral discharge (91%), reported oral sex with a female in the last 12 months (96%), and were treated with a ceftriaxone-based regimen (95%). A minority (15%) also had urethral chlamydia coinfection. All urethral Nm isolates were nongroupable, ST-11 clonal complex (cc11), ET-15, and clustered together phylogenetically. Urethral Nm isolates were similar by fine typing (PorA P1.5-1,10-8, PorB 2-2, FetA F3-6), except 2, which had different PorB types (2-78 and 2-52). Between January and November 2015, 75 urethritis cases due to a distinct Nm clade occurred among primarily black, heterosexual men in Columbus, Ohio. Future urogenital Nm infection studies should focus on pathogenesis and modes of sexual transmission. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  12. Haemophilus parainfluenzae urethritis among homosexual men.

    Science.gov (United States)

    Hsu, Meng-Shiuan; Wu, Mei-Yu; Lin, Tsui-Hsien; Liao, Chun-Hsing

    2015-08-01

    Haemophilus parainfluenzae is a common inhabitant of the human upper respiratory tract of the normal oral microflora. We report three men who had been having unprotected sex with men (MSM) and subsequently acquired H. parainfluenzae urethritis, which was confirmed by 16S rRNA gene sequencing analysis. Two men were treated with ceftriaxone and doxycycline, and the third man was treated with clarithromycin. All three patients responded to treatment. This case series highlights the potential role of H. parainfluenzae as a sexually transmitted genitourinary pathogen. Copyright © 2012. Published by Elsevier B.V.

  13. Mycoplasmas and Non-gonococcal Urethritis

    Directory of Open Access Journals (Sweden)

    Bhushan Kumar

    1989-01-01

    Full Text Available A total of 692 heterosexual males which included 130 men with non-gonoccal urethritis (NGU and 562 age-matched controls, were studied. Mycoplasmas were cultivated in liquid PPLO medium tubes containing arionine and urea. Mycoplasmas were isolated in 24 (18.59o of the 130 patients and 76 (13.60/o of the 562 controls. Ureaplasma urealyticum was isolated in 18 (13.9% gatients with NGU and in 21 (3.8% controls. Mycoplasma hominiq was isolated in 6 (4.6% patientuft NGU and in 55 (9.8% controls. Ureaplasma urealyticurm has a definite in NGU.

  14. Urethral catheters: can we reduce use?

    Directory of Open Access Journals (Sweden)

    van den Akker-van Marle M Elske

    2011-05-01

    Full Text Available Abstract Background Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. Methods The efficacy of an intervention programme to improve adherence to recommendations to reduce the use of urethral catheters was studied in a before-after comparison in ten Dutch hospitals. The programme detected barriers and facilitators and each individual facility was supported with developing their own intervention strategy. Outcome was evaluated by the prevalence of catheters, alternatives such as diapers, numbers of urinary tract infections, the percentage of correct indications and the duration of catheterization. The costs of the implementation as well as the catheterization were evaluated. Results Of a population of 16,495 hospitalized patients 3335 patients of whom 2943 were evaluable for the study, had a urethral catheter. The prevalence of urethral catheters decreased insignificantly in neurology (OR 0.93; 95% CI 0.77 - 1.13 and internal medicine wards (OR 0.97; 95% CI 0.83 - 1.13, decreased significantly in surgical wards (OR 0.84; 95% CI 0.75 - 0.96, but increased significantly in intensive care (IC and coronary care (CC units (OR 1.48; 95% CI 1.01 - 2.17. The use of alternatives was limited and remained so after the intervention. Duration of catheterization decreased insignificantly in IC/CC units (ratio after/before 0.95; 95% CI 0.78 - 1.16 and neurology (ratio 0.97; 95% CI 0.80 - 1.18 and significantly in internal medicine (ratio 0.81; 95% CI 0.69 - 0.96 and surgery wards (ratio 0.80; 95% CI 0.71 - 0.90. The percentage of correct indications on the day of inclusion increased from 50 to 67% (p Conclusion Targeted implementation of recommendations from an existing guideline can lead to better adherence and cost savings. Especially, hospitals which use a lot of urethral catheters or

  15. Aetiology of male urethritis in patients recruited from a population with a high HIV prevalence.

    NARCIS (Netherlands)

    Sturm, P.D.J.; Moodley, P.; Khan, N.; Ebrahim, S.; Govender, K.; Connolly, C.E.; Sturm, A.W.

    2004-01-01

    The aetiology of urethritis, the significance of potential pathogens and the relation of urethritis to HIV infection were determined in 335 men (cases) with and 100 men (controls) without urethral symptoms. Urethral swab specimens were tested for different organisms by PCR or by culture for

  16. Bladder pressure measurements and urinary tract infection in trauma patients.

    Science.gov (United States)

    Duane, Therèse M; Young, Andrew; Weber, William; Wolfe, Luke G; Malhotra, Ajai K; Aboutanos, Michel B; Whelan, James F; Mayglothling, Julie; Ivatury, Rao R

    2012-04-01

    The purpose of this trial was to determine if using a closed technique for bladder pressure measurements (BPMs) would eliminate them as a risk factor for urinary tract infection (UTI) in trauma patients, as was shown previously using an open technique. Data were collected prospectively from January 2006 until December 2009 by a dedicated epidemiology nurse and combined with trauma registry data at our Level 1 trauma center. All trauma patients admitted to the surgical trauma intensive care unit (STICU) with and without UTIs were compared for demographic and epidemiologic data. A closed system was used in which the urinary drainage catheter (UDC) remained connected to the bag and 45 mL of saline was injected through a two-way valved sideport, with subsequent measurements through the sideport. There were 1,641 patients in the trial. The UTI group was sicker (Injury Severity Score [ISS] 18.7±11.9 no UTI vs. 28±10.7 UTI; p<0.0001), with longer stays (11.4±12.4 days no UTI vs. 37.9±20.3 days UTI; p<0.0001) and more UDC days (4.3±6.6 no UTI vs. 23.9±16.6 UTI; p<0.0001). The BPM group had more UDC days (15.6 days±16.0 BPM vs. 5.4 days±7.3 no BPM; p<0.0001), yet no difference in UTI rate/1,000 UDC days (5.7 no BPM vs. 8.0 BPM; p=0.5291). Logistic regression demonstrated only UDC days to be a predictor of UTI (1.125; 95% confidence interval [CI] 1.097-1.154; p<0.0001), whereas ISS (1.083, 95% CI 1.063-1.104; p<0.0001) and age (1.051, 95% CI 1.037-1.065; p<0.0001) were the only predictors of death. Although patients undergoing BPM have more UTIs than patients without BPM, the measurements are not an independent predictor of UTI when done by the closed technique. These findings emphasize the judicious use of BPM with a closed system and, more importantly, the need for early removal of catheters.

  17. Peripheral arterial volume distensibility: significant differences with age and blood pressure measured using an applied external pressure

    International Nuclear Information System (INIS)

    Zheng, Dingchang; Murray, Alan

    2011-01-01

    A new arterial distensibility measurement technique was assessed in 100 healthy normotensive subjects. Arterial transmural pressures on the whole right arm were reduced with a 50 cm long cuff inflated to 10, 20, 30 and 40 mmHg. The electrocardiogram, and finger and ear photoplethysmograms were recorded simultaneously. Arm pulse propagation time, pulse wave velocity (PWV) and arterial volume distensibility were determined. With a 40 mmHg reduction in transmural pressure, arm pulse propagation time increased from 61 to 83 ms, PWV decreased from 12 to 8 m s −1 and arterial distensibility increased from 0.102% to 0.232% per mmHg (all P < 0.0001). At all cuff pressures, arterial distensibility was significantly related to resting mean arterial pressure (MAP), diastolic blood pressure (DBP) and age, and for systolic blood pressure at 30 and 40 mmHg (all P < 0.05). At 40 mmHg cuff pressure, arterial distensibility fell by 54% for a MAP increase from 75 to 105 mmHg, 57% for a DBP increase from 60 to 90 mmHg and 47% for an age increase from 20 to 70 years. These changes were more than double than those without cuff pressure. Our technique showed that systemic volume distensibility of the peripheral arm artery reduced with age, with a greater effect at higher external and lower transmural pressures

  18. A novel high pressure, high temperature vessel used to conduct long-term stability measurements of silicon MEMS pressure transducers

    Science.gov (United States)

    Wisniewiski, David

    2014-03-01

    The need to quantify and to improve long-term stability of pressure transducers is a persistent requirement from the aerospace sector. Specifically, the incorporation of real-time pressure monitoring in aircraft landing gear, as exemplified in Tire Pressure Monitoring Systems (TPMS), has placed greater demand on the pressure transducer for improved performance and increased reliability which is manifested in low lifecycle cost and minimal maintenance downtime through fuel savings and increased life of the tire. Piezoresistive (PR) silicon MEMS pressure transducers are the primary choice as a transduction method for this measurement owing to their ability to be designed for the harsh environment seen in aircraft landing gear. However, these pressure transducers are only as valuable as the long-term stability they possess to ensure reliable, real-time monitoring over tens of years. The "heart" of the pressure transducer is the silicon MEMS element, and it is at this basic level where the long-term stability is established and needs to be quantified. A novel High Pressure, High Temperature (HPHT) vessel has been designed and constructed to facilitate this critical measurement of the silicon MEMS element directly through a process of mechanically "floating" the silicon MEMS element while being subjected to the extreme environments of pressure and temperature, simultaneously. Furthermore, the HPHT vessel is scalable to permit up to fifty specimens to be tested at one time to provide a statistically significant data population on which to draw reasonable conclusions on long-term stability. With the knowledge gained on the silicon MEMS element, higher level assembly to the pressure transducer envelope package can also be quantified as to the build-effects contribution to long-term stability in the same HPHT vessel due to its accommodating size. Accordingly, a HPHT vessel offering multiple levels of configurability and robustness in data measurement is presented, along

  19. Using the area under the curve to reduce measurement error in predicting young adult blood pressure from childhood measures.

    Science.gov (United States)

    Cook, Nancy R; Rosner, Bernard A; Chen, Wei; Srinivasan, Sathanur R; Berenson, Gerald S

    2004-11-30

    Tracking correlations of blood pressure, particularly childhood measures, may be attenuated by within-person variability. Combining multiple measurements can reduce this error substantially. The area under the curve (AUC) computed from longitudinal growth curve models can be used to improve the prediction of young adult blood pressure from childhood measures. Quadratic random-effects models over unequally spaced repeated measures were used to compute the area under the curve separately within the age periods 5-14 and 20-34 years in the Bogalusa Heart Study. This method adjusts for the uneven age distribution and captures the underlying or average blood pressure, leading to improved estimates of correlation and risk prediction. Tracking correlations were computed by race and gender, and were approximately 0.6 for systolic, 0.5-0.6 for K4 diastolic, and 0.4-0.6 for K5 diastolic blood pressure. The AUC can also be used to regress young adult blood pressure on childhood blood pressure and childhood and young adult body mass index (BMI). In these data, while childhood blood pressure and young adult BMI were generally directly predictive of young adult blood pressure, childhood BMI was negatively correlated with young adult blood pressure when childhood blood pressure was in the model. In addition, racial differences in young adult blood pressure were reduced, but not eliminated, after controlling for childhood blood pressure, childhood BMI, and young adult BMI, suggesting that other genetic or lifestyle factors contribute to this difference. 2004 John Wiley & Sons, Ltd.

  20. Does the Position or Contact Pressure of the Stethoscope Make Any Difference to Clinical Blood Pressure Measurements

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-01-01

    Abstract This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP. PMID:25546675

  1. Does the position or contact pressure of the stethoscope make any difference to clinical blood pressure measurements: an observational study.

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-12-01

    This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP.

  2. Long-term outcome of primary endoscopic realignment for bulbous urethral injuries: risk factors of urethral stricture.

    Science.gov (United States)

    Seo, Ill Young; Lee, Jea Whan; Park, Seung Chol; Rim, Joung Sik

    2012-12-01

    Although endoscopic realignment has been accepted as a standard treatment for urethral injuries, the long-term follow-up data on this procedure are not sufficient. We report the long-term outcome of primary endoscopic realignment in bulbous urethral injuries. Patients with bulbous urethral injuries were treated by primary endoscopic realignment between 1991 and 2005. The operative procedure included suprapubic cystostomy and transurethral catheterization using a guide wire, within 72 hours of injury. The study population included 51 patients with a minimum follow-up duration of 5 years. The most common causes of the injuries were straddle injury from falling down (74.5%), and pelvic bone fracture (7.8%). Gross hematuria was the most common complaint (92.2%). Twenty-three patients (45.1%) had complete urethral injuries. The mean time to operation after the injury was 38.8±43.2 hours. The mean operation time and mean indwelling time of a urethral Foley catheter were 55.5±37.6 minutes and 22.0±11.9 days, respectively. Twenty out of 51 patients (39.2%) were diagnosed with urethral stricture in 89.1±36.6 months after surgery. A multivariate analysis revealed that young age and operation time were independent risk factors for strictures as a complication of urethral realignment (hazard ratio [HR], 6.554, P=0.032; HR, 6.206, P=0.035). Urethral stricture commonly developed as a postoperative complication of primary endoscopic urethral realignment for bulbous urethral injury, especially in young age and long operation time.

  3. High pressure cells for magnetic measurements - destruction and functional tests

    Czech Academy of Sciences Publication Activity Database

    Kamarád, Jiří; Machátová, Zuzana; Arnold, Zdeněk

    2004-01-01

    Roč. 75, č. 11 (2004), s. 5022-5025 ISSN 0034-6748 R&D Projects: GA ČR GA202/02/0739; GA AV ČR IAA1010315 Institutional research plan: CEZ:AV0Z1010914 Keywords : pressure cells * pressure transmitting media * CuBe * MP35N Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.226, year: 2004

  4. Effect of Foley catheters on seed positions and urethral dose in 125I and 103Pd prostate implants

    International Nuclear Information System (INIS)

    Brezovich, Ivan A.; Pareek, Prem N.; Duan, Jun; Fiveash, John

    2001-01-01

    Purpose: To estimate the perturbation of seed position and urethral dose, subsequent to withdrawal of urethral catheters. Methods and Materials: A mathematical model based on the volume incompressibility of tissues was used to compute seed positions and doses following removal of the Foley. The model assumed that the central axis of the urethra remains stationary, and that prostate tissue and seeds move radially toward the center of the urethra to fill the void left by the catheter. Seed motion has also been measured using transrectal ultrasound. Results: Based on the computations, seeds located originally close to the urethra travel relatively large distances toward the urethra upon Foley removal, whereas seeds located further away move substantially less. This seed motion leads to higher urethral doses than shown in a standard treatment plan. Dose enhancements increase with catheter size, decrease with increasing prostate volume, are more pronounced for 103 Pd than for 125 I, and range between 3.5% and 32.4%. Postimplant dosimetry is equally affected if images are taken with urethral catheters in place, showing lower urethral doses than actually delivered. Preliminary ultrasound based measurements of seed motion agree with the theory. Conclusion: During the implantation procedure, 12 fr or smaller urethral catheters are preferable to larger diameter catheters if urine drainage is sufficient. Treatment planners should avoid planning seeds at 5 mm or closer from the urethra. Special caution is indicated in prostates having about 20 cm 3 or smaller volumes, and when 103 Pd is used. Postimplant dosimetry is susceptible to the same errors

  5. Response characteristics of probe-transducer systems for pressure measurements in gas-solid fluidized beds: how to prevent pitfalls in dynamic pressure measurements

    NARCIS (Netherlands)

    Ommen, van J.R.; Schouten, J.C.; Stappen, van der M.L.M.; Bleek, van den C.M.

    1999-01-01

    It is long known already that the pressure probe–transducer systems applied in gas–solid fluidized beds can distort the measured pressure fluctuations. Several rules of thumb have been proposed to determine probe length and internal diameter required to prevent this. Recently, Xie and Geldart [H.-Y.

  6. Adult urethral stricture: practice of Turkish urologists

    Science.gov (United States)

    Akyuz, Mehmet; Sertkaya, Zulfu; Koca, Orhan; Calıskan, Selahattin; Kutluhan, Musab Ali; Karaman, Muhammet Ihsan

    2016-01-01

    ABSTRACT Objectives: To evaluate national practice patterns in the treatment of male anterior urethral strictures among Turkish urologists. Materials and Methods: A survey form including 12 questions prepared to determine active Turkish urologists' approach to diagnosis and treatment of the adult urethral stricture (US) were filled out. Based on the survey results, the institutions which 218 urologists work and their years of expertise, methods they used for diagnosis and treatment, whether or not they perform open urethroplasty and timing of open urethroplasty were investigated. Results: Optic internal urethrotomy and dilatation are the most commonly used minimal invasive procedures in treatment of US with the ratios of 93.5% and 63.3% respectively. On the other hand it was seen that urethroplasty was a less commonly used procedure, compared to minimal invasive techniques, with the ratio of 36.7%. Survey results showed us that the number of US cases observed and open urethroplasty procedures performed increases with increasing years of professional experience. Conclusions: As a method demanding special surgical experience and known as a time-consuming and challenging procedure, open urethroplasty will be able to take a greater part in current urological practice with the help of theoretical education and practical courses given by specific centers and experienced authors. PMID:27256189

  7. Adult urethral stricture: practice of Turkish urologists

    Directory of Open Access Journals (Sweden)

    Mehmet Akyuz

    2016-04-01

    Full Text Available ABSTRACT Objectives: To evaluate national practice patterns in the treatment of male anterior urethral strictures among Turkish urologists. Materials and Methods: A survey form including 12 questions prepared to determine active Turkish urologists' approach to diagnosis and treatment of the adult urethral stricture (US were filled out. Based on the survey results, the institutions which 218 urologists work and their years of expertise, methods they used for diagnosis and treatment, whether or not they perform open urethroplasty and timing of open urethroplasty were investigated. Results: Optic internal urethrotomy and dilatation are the most commonly used minimal invasive procedures in treatment of US with the ratios of 93.5% and 63.3% respectively. On the other hand it was seen that urethroplasty was a less commonly used procedure, compared to minimal invasive techniques, with the ratio of 36.7%. Survey results showed us that the number of US cases observed and open urethroplasty procedures performed increases with increasing years of professional experience. Conclusions: As a method demanding special surgical experience and known as a time-consuming and challenging procedure, open urethroplasty will be able to take a greater part in current urological practice with the help of theoretical education and practical courses given by specific centers and experienced authors.

  8. Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Pierre Galvagni Silveira

    2008-01-01

    Full Text Available PURPOSE: To establish a correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter placed in the same aneurysm sac before and after its exclusion by an endoprosthesis. METHODS: Patients who underwent endovascular abdominal aortic aneurysm repair and received an EndoSureTM wireless pressure sensor implant between March 19 and December 11, 2004 were enrolled in the study. Simultaneous readings of systolic, diastolic, mean, and pulse pressure within the aneurysm sac were obtained from the catheter and the sensor, both before and after sac exclusion by the endoprosthesis (Readings 1 and 2, respectively. Intrasac pressure measurements were compared using Pearson's correlation and Student's t test. Statistical significance was set at p0.05, mean (p>0.05, and pulse (p0.05 by the sensor. CONCLUSION: The excellent agreement between intrasac pressure readings recorded by the catheter and the sensor justifies use of the latter for detection of post-exclusion abdominal aortic aneurysm pressurization.

  9. Pressure Measurement Techniques for Abdominal Hypertension: Conclusions from an Experimental Model.

    Science.gov (United States)

    Chopra, Sascha Santosh; Wolf, Stefan; Rohde, Veit; Freimann, Florian Baptist

    2015-01-01

    Introduction. Intra-abdominal pressure (IAP) measurement is an indispensable tool for the diagnosis of abdominal hypertension. Different techniques have been described in the literature and applied in the clinical setting. Methods. A porcine model was created to simulate an abdominal compartment syndrome ranging from baseline IAP to 30 mmHg. Three different measurement techniques were applied, comprising telemetric piezoresistive probes at two different sites (epigastric and pelvic) for direct pressure measurement and intragastric and intravesical probes for indirect measurement. Results. The mean difference between the invasive IAP measurements using telemetric pressure probes and the IVP measurements was -0.58 mmHg. The bias between the invasive IAP measurements and the IGP measurements was 3.8 mmHg. Compared to the realistic results of the intraperitoneal and intravesical measurements, the intragastric data showed a strong tendency towards decreased values. The hydrostatic character of the IAP was eliminated at high-pressure levels. Conclusion. We conclude that intragastric pressure measurement is potentially hazardous and might lead to inaccurately low intra-abdominal pressure values. This may result in missed diagnosis of elevated abdominal pressure or even ACS. The intravesical measurements showed the most accurate values during baseline pressure and both high-pressure plateaus.

  10. [Neisseria meningitidis urethritis: Two case reports].

    Science.gov (United States)

    Dubois, C; Liegeon, A-L; Fabbro, C; Truchetet, F

    2017-10-01

    Neisseria meningitidis (NM) is a commensal bacteria present in the oropharyngeal flora that causes invasive infections. There have been rarer reports of presence in the genital region. Herein, we present two cases of acute NM urethritis. Two men aged 30 and 31years, one of whom is homosexual and seropositive for HIV infection, presented urethral discharge which was diagnosed as acute urethritis. The unit through samples indicated the presence of NM of serogroups B and C. One of the antibiotic sensitivity tests revealed intermediate susceptibility to penicillin G and to amoxicillin. The clinical presentation of acute NM urethritis is non-specific, because of which urethral samples should be taken wherever acute urethritis is suspected. NM urethritis is infrequent and primarily affects men who have sex with men (MSM). Its current increase is due to unprotected oral-genital sexual practices. Due to the emergence of resistance to NM, antibiotic susceptibility testing should be carried out routinely to ensure appropriate therapy and prophylaxis. Cases of invasive serogroup C meningococcal infections have been recorded within the MSM population with hypothetical sexual port of entry. Thus, the French High Public Health Authority recommends vaccination against meningitis C in this population. Copyright © 2017. Published by Elsevier Masson SAS.

  11. Advances in the Understanding and Treatment of Male Urethritis.

    Science.gov (United States)

    Bachmann, Laura H; Manhart, Lisa E; Martin, David H; Seña, Arlene C; Dimitrakoff, Jordan; Jensen, Jørgen Skov; Gaydos, Charlotte A

    2015-12-15

    Neisseria gonorrhoeae and Chlamydia trachomatis are well-documented urethral pathogens, and the literature supporting Mycoplasma genitalium as an etiology of urethritis is growing. Trichomonas vaginalis and viral pathogens (herpes simplex virus types 1 and 2 and adenovirus) can cause urethritis, particularly in specific subpopulations. New data are emerging regarding the potential role of bacterial vaginosis-associated bacteria in urethritis, although results are inconsistent regarding the pathogenic role of Ureaplasma urealyticum in men. Mycoplasma hominis and Ureaplasma parvum do not appear to be pathogens. Men with suspected urethritis should undergo evaluation to confirm urethral inflammation and etiologic cause. Although nucleic acid amplification testing would detect N. gonorrhoeae and C. trachomatis (or T. vaginalis if utilized), there is no US Food and Drug Administration-approved clinical test for M. genitalium available in the United States at this time. The varied etiologies of urethritis and lack of diagnostic options for some organisms present treatment challenges in the clinical setting. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  12. [Chlamydia trachomatis and urogenital mycoplasms in nonconococcal urethritis in men].

    Science.gov (United States)

    Vesić, Sonja; Vukićević, Jelica; Gvozdenović, Eleonora; Skiljević, Dusan; Janosević, Slobodanka; Medenica, Ljiljana

    2010-01-01

    Nongonococcal urethritis is the most common sexually transmitted infection in men, with vast majority of the etiological agents such as Chlamydia trachomatis, followed by urogenital mycoplasmas. The aim of this study was to determine the prevalence of Chlamydia trachomatis, Ureaplasma urealyticum and Mycoplasma hominis in nongonococcal urethritis in men, and to examine infections associated with these agents. Material and methods 299 sexually active, heterosexual men with nongonococcal urethritis were included into the study. Urethral samples were taken with a dacron swab placed into the urethra up to 2-3 cm. The Direct immunofluorescence technique was performed for identification of Chlamydia trachomatis. Ureaplasma urealyticum and Mycoplasma hominis were detected with Mycoplasma IST assay. Chlamydia trachomatis was detected in 22.75%, Uraeplasma urealyticum in 21.08% and Mycoplasma hominis in 8.02% cases. We found no significant differences in prevalence between Chlamydia trachomatis and Ureaplasma urealyticym (p > 0.05). Monoinfections were found in 51.85% with significantly higher rate (p urethritis with prevalence of 51.85% in monoinfections and 11.70% in associated infections. In 36.45% of cases the etiology of urethritis was not elucidated. These results suggest that more sensitive diagnostic tool should be applied when searching for the derailed etiology of nongonococcal urethritis.

  13. Meatal Swabs Contain Less Cellular Material and Are Associated with a Decrease in Gram Stain Smear Quality Compared to Urethral Swabs in Men.

    Science.gov (United States)

    Jordan, Stephen J; Schwebke, Jane R; Aaron, Kristal J; Van Der Pol, Barbara; Hook, Edward W

    2017-07-01

    Urethral swabs are the samples of choice for point-of-care Gram stain testing to diagnose Neisseria gonorrhoeae infection and nongonococcal urethritis (NGU) in men. As an alternative to urethral swabs, meatal swabs have been recommended for the collection of urethral discharge to diagnose N. gonorrhoeae and Chlamydia trachomatis infection in certain populations by nucleic acid amplification testing (NAAT), as they involve a less invasive collection method. However, as meatal swabs could be sampling a reduced surface area and result in fewer collected epithelial cells compared to urethral swabs, the adequacy of meatal swab specimens to collect sufficient cellular material for Gram stain testing remains unknown. We enrolled 66 men who underwent either urethral or meatal swabbing and compared the cellular content and Gram stain failure rate. We measured the difference in swab cellular content using the Cepheid Xpert CT/NG sample adequacy control crossing threshold (SAC CT ) and determined the failure rate of Gram stain smears (GSS) due to insufficient cellular material. In the absence of discharge, meatal smears were associated with a significant reduction in cellular content ( P = 0.0118), which corresponded with a GSS failure rate significantly higher than that for urethral swabs (45% versus 3%, respectively; P < 0.0001). When discharge was present, there was no difference among results from urethral and meatal swabs. Therefore, if GSS testing is being considered for point-of-care diagnosis of N. gonorrhoeae infection or NGU in men, meatal swabs should be avoided in the absence of a visible discharge. Copyright © 2017 American Society for Microbiology.

  14. Aortic blood pressure measured via EIT: investigation of different measurement settings.

    Science.gov (United States)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Adler, Andy; Grychtol, Bartłomiej; Solà, Josep; Thiran, Jean-Philippe

    2015-06-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.

  15. Aortic blood pressure measured via EIT: investigation of different measurement settings

    International Nuclear Information System (INIS)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Solà, Josep; Adler, Andy; Grychtol, Bartłomiej; Thiran, Jean-Philippe

    2015-01-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss–Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss–Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg. (paper)

  16. [Efficacy and safety of levofloxacin to non-gonorrheal urethritis].

    Science.gov (United States)

    Onodera, Shoichi; Onoe, Yasuhiko; Hosobe, Takahide; Kato, Tetsuro; Yoshida, Masaki

    2012-12-01

    We investigated the efficacy and safety of levofloxacin (LVFX) 500mg once a day in patients with non-gonorrheal urethritis. Men, aged 20 years or older, with urethritis symptoms, and detection of Chlamydia trachomatis (C. trachomatis) or Mycoplasma genitalium (M. genitalium) by a microbiological examination were eligible for this study. Patients were administered LVFX 500mg, orally, once a day and the dosage period was seven days. We assumed 22 patients for a safety and efficacy analysis. In 22 patients, 17 patients had urethritis with C. trachomatis, 4 patients urethritis with M. genitalium, and one patient mixed infection of C. trachomatis and M. genitalium. In the clinial study, the primary endpoint was set as the bacteriological eradication rate at two to four weeks after completion of treatment. The bacterial eradication rate in the urethritis was 86.4% (19/22). The bacterial eradication rate in the urethritis with C. trachomatis, M. genitalium, and mixed infection of C. trachomatis and M. genitalium were 94.1% (16/17), 50.0% (2/4), 100% (1/1), respectively. A significant difference was not recognized among the three groups. The clinical efficacy at two to four weeks after completion of treatment was 90.9% (20/22). The clinical efficacy rates in the urethritis with C. trachomatis, M. genitalium, and mixed infection of C. trachomatis and M. genitalium were 100% (17/17), 50.0% (2/4), 100% (1/1), respectively. The efficacy rate of urethritis with M. genitalium was significantly low. No adverse drug reactions were observed. These results suggest that once-a-day levofloxacin (500mg) is effective and safe treatment for non-gonorrheal urethritis.

  17. Studies of Protein Solution Properties Using Osmotic Pressure Measurements

    Science.gov (United States)

    Agena, S.; Bogle, David; Pusey, Marc; Agena, S.

    1998-01-01

    Examination of the protein crystallization process involves investigation of the liquid and solid state and a protein's properties in these states. Liquid state studies such as protein self association in solution by light scattering methods or other methods have been used to examine a protein Is properties and therefore its crystallization process and conditions. Likewise can osmotic pressure data be used to examine protein properties and various published osmotic pressure studies were examined by us to correlate osmotic pressure to protein solution properties. The solution behavior of serum albumin, alpha - chymotrypsin, beta - lactoglobulin and ovalbumin was examined over a range of temperatures, pH values and different salt types and concentrations. Using virial expansion and a local composition model the non ideal solution behavior in form of the activity coefficients (thermodynamic) was described for the systems. This protein activity coefficient data was related to a protein's solubility behavior and this process and the results will be presented.

  18. Glucose Monitoring System Based on Osmotic Pressure Measurements

    Directory of Open Access Journals (Sweden)

    Alexandra LEAL

    2011-02-01

    Full Text Available This paper presents the design and development of a prototype sensor unit for implementation in a long-term glucose monitoring system suitable for estimating glucose levels in people suffering from diabetes mellitus. The system utilizes osmotic pressure as the sensing mechanism and consists of a sensor prototype that is integrated together with a pre-amplifier and data acquisition unit for both data recording and processing. The sensor prototype is based on an embedded silicon absolute pressure transducer and a semipermeable nanoporous membrane that is enclosed in the sensor housing. The glucose monitoring system facilitates the integration of a low power microcontroller that is combined with a wireless inductive powered communication link. Experimental verification have proven that the system is capable of tracking osmotic pressure changes using albumin as a model compound, and thereby show a proof of concept for novel long term tracking of blood glucose from remote sensor nodes.

  19. Risk evaluation on the basis of pressure rate measured by automatic pressure tracking adiabatic calorimeter.

    Science.gov (United States)

    Iwata, Yusaku; Koseki, Hiroshi

    2008-11-15

    An automatic pressure tracking adiabatic calorimeter (APTAC) had been employed to obtain the thermokinetic and the vapor pressure data during runaway reactions. The APTAC is an adiabatic calorimeter with a large-scale sample mass and low thermal inertia, and is an extremely useful tool for assessing thermal hazards of reactive chemicals. The data obtained by the APTAC are important information for the design of the safe industrial process. The thermodynamics parameters and the gas production were discussed on the basis of the experimental data of various concentrations and weights of di-tert-butyl peroxide (DTBP)/toluene solution for the purpose of investigating the properties of the APTAC data. The thermal decomposition of DTBP was studied on the basis of the temperature data and the pressure data obtained by the APTAC. The activation energy and the frequency factor of DTBP are nearly constant and the same as the literature values in the concentrations between 20 and 60 wt.%. The pressure rise due to gas production is important data for designing the relief vent of a reactor. The time history of the gas production was investigated with various weights and concentrations. The total gas production index, which had the vapor pressure correction, was 1.0 in the decomposition of DTBP.

  20. Risk evaluation on the basis of pressure rate measured by automatic pressure tracking adiabatic calorimeter

    International Nuclear Information System (INIS)

    Iwata, Yusaku; Koseki, Hiroshi

    2008-01-01

    An automatic pressure tracking adiabatic calorimeter (APTAC) had been employed to obtain the thermokinetic and the vapor pressure data during runaway reactions. The APTAC is an adiabatic calorimeter with a large-scale sample mass and low thermal inertia, and is an extremely useful tool for assessing thermal hazards of reactive chemicals. The data obtained by the APTAC are important information for the design of the safe industrial process. The thermodynamics parameters and the gas production were discussed on the basis of the experimental data of various concentrations and weights of di-tert-butyl peroxide (DTBP)/toluene solution for the purpose of investigating the properties of the APTAC data. The thermal decomposition of DTBP was studied on the basis of the temperature data and the pressure data obtained by the APTAC. The activation energy and the frequency factor of DTBP are nearly constant and the same as the literature values in the concentrations between 20 and 60 wt.%. The pressure rise due to gas production is important data for designing the relief vent of a reactor. The time history of the gas production was investigated with various weights and concentrations. The total gas production index, which had the vapor pressure correction, was 1.0 in the decomposition of DTBP

  1. Comparison between transurethral ultrasound and conventional urethrography in male urethral stricture

    International Nuclear Information System (INIS)

    Fernandez, G. C.; Rivas, C.; Rivas, B.; Perez, M.; Peasqueira, D.; Tardaguila, F.

    2001-01-01

    To define the role of transurethral ultrasound in the study of male urethral structure. A prospective study was carried out in 19 consecutive patients with male urethral structure, diagnosed by means of conventional urethrography, who subsequently underwent transurethral ultrasound. The latter study consisted of the introduction of a Foley catheter (8 or 10 F) and gradual inflation of the balloon within the navicular fossa. Sterile saline solution was then slowly and continuously infused while the ultrasound was carried out by placing the transducer on the ventral aspect of the penis and in the perineal region to identify the different portions of the urethra. The location and extension of the structure were determined by both radiological techniques, and adjacent areas of fibrosis (spongiofibrosis) were detected by ultrasound. The results correlated with the pathological findings in 10 case. There was good agreement between the two techniques in the localization of the structure (kappa=0.81). However, there were statistically significant differences in the measurements of the extension (p=0.01). Transurethral ultrasound revealed areas of spongiofibrosis adjacent to the structure that presented a different echogenicity. The results of the measurement of their extension were not significantly different from those found in the pathological study. Transurethral ultrasound is more effective than conventional urethrography in the study of urethral structure since it permits the precise measurement and localization of the structure and the visualization of the zone of spongiofibrosis, a determining factor in surgical planning. (Author) 11 refs

  2. [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].

    Science.gov (United States)

    Zhou, Xia; Wu, Wenli; Bao, Shudi

    2015-07-01

    IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.

  3. Research on Water Velocity Measurement of Reservoir Based on Pressure Sensor

    Directory of Open Access Journals (Sweden)

    Xiaoqiang Zhao

    2014-11-01

    Full Text Available To address the problem that pressure sensor can only measure the liquid level in reservoir, we designed a current velocity measurement system of reservoir based on pressure sensor, analyzed the error of current velocity measurement system, and proposed the error processing method and corresponding program. Several tests and experimental results show that in this measurement system, the liquid level measurement standard deviation is no more than 0.01 cm, and the current velocity measurement standard deviation is no more than 0.35 mL/s, which proves that the pressure sensor can measure both liquid level and current velocity synchronously.

  4. Measuring Vapor Pressure with an Isoteniscope: A Hands-on Introduction to Thermodynamic Concepts

    Science.gov (United States)

    Chen, Wenqian; Haslam, Andrew J.; Macey, Andrew; Shah, Umang V.; Brechtelsbauer, Clemens

    2016-01-01

    Characterization of the vapor pressure of a volatile liquid or azeotropic mixture, and its fluid phase diagram, can be achieved with an isoteniscope and an industrial grade digital pressure sensor using the experimental method reported in this study. We describe vapor-pressure measurements of acetone and n-hexane and their azeotrope, and how the…

  5. A simple technique for measurement of pressure in the tympanitic rumen of cattle.

    Science.gov (United States)

    Turner, C B; Whyte, T D

    1978-05-13

    The construction and method of use of a simple device for the non-invasive measurement of intra-rumenal pressure is outlined. Results obtained from calves suffering from increased intra-rumenal pressure (bloat) are shown. The method is capable of quantifying pressures involved in bloat and could be used to augment the visual assessment of bloat scoring.

  6. Healing of ulcers on the feet correlated with distal blood pressure measurements in occlusive arterial disease

    DEFF Research Database (Denmark)

    Holstein, P; Lassen, N A

    1980-01-01

    The frequency of healing in subchronic ulcers in 66 feet in 62 patients with arterial occlusive disease was correlated with the systolic digital blood pressure (SDBP) and the systolic ankle blood pressure (SABP), both measured with a strain gauge, and with the skin perfusion pressure on the heel...

  7. Spectrally resolved pressure dependence measurements of air fluorescence emission with AIRFLY

    International Nuclear Information System (INIS)

    Ave, M.; Bohacova, M.; Buonomo, B.; Busca, N.; Cazon, L.; Chemerisov, S.D.; Conde, M.E.; Crowell, R.A.; Di Carlo, P.; Di Giulio, C.; Doubrava, M.; Esposito, A.; Facal, P.; Franchini, F.J.; Hoerandel, J.; Hrabovsky, M.; Iarlori, M.; Kasprzyk, T.E.; Keilhauer, B.; Klages, H.

    2008-01-01

    The knowledge of the fluorescence emission as a function of atmospheric parameters is essential for the detection of extensive air showers with the fluorescence technique. In this paper, we summarize AIRFLY published measurements of the pressure dependence of the fluorescence yield. The spectral distribution of the fluorescent light between 280 and 429 nm has been measured with high resolution. Relative intensities of 34 spectral lines have been determined. The pressure dependence of 25 lines was measured in terms of quenching reference pressures p λ ' in air. This set of AIRFLY measurements yields the most comprehensive parametrization of the pressure dependence of the fluorescent spectrum.

  8. Performance evaluation of Honeywell silicon piezoresistive pressure transducers for oceanographic and limnological measurements

    Digital Repository Service at National Institute of Oceanography (India)

    VijayKumar, K.; Joseph, A.; Desai, R.G.P.; Prabhudesai, S.; Nagvekar, S.; Damodaran, V.

    results have indicated that a suitably calibrated temperature-compensated Honeywell PPTR provides an alternate cost-effective means for pressure measurements for coastal oceanographic and limnological studies....

  9. X-ray reflectivity measurements of liquid/solid interfaces under high hydrostatic pressure conditions.

    Science.gov (United States)

    Wirkert, Florian J; Paulus, Michael; Nase, Julia; Möller, Johannes; Kujawski, Simon; Sternemann, Christian; Tolan, Metin

    2014-01-01

    A high-pressure cell for in situ X-ray reflectivity measurements of liquid/solid interfaces at hydrostatic pressures up to 500 MPa (5 kbar), a pressure regime that is particularly important for the study of protein unfolding, is presented. The original set-up of this hydrostatic high-pressure cell is discussed and its unique properties are demonstrated by the investigation of pressure-induced adsorption of the protein lysozyme onto hydrophobic silicon wafers. The presented results emphasize the enormous potential of X-ray reflectivity studies under high hydrostatic pressure conditions for the in situ investigation of adsorption phenomena in biological systems.

  10. NORMAL PRESSURE AND FRICTION STRESS MEASUREMENT IN ROLLING PROCESSES

    DEFF Research Database (Denmark)

    Henningsen, Poul; Arentoft, Mogens; Lagergren, Jonas

    2005-01-01

    the output from the transducer, the friction stress and normal pressure in the contact zone can be determined. The new concept differs from existing pin designs by a lower disturbance of lubricant film and material flow and limited penetration of material between transducer and roll. Aluminum, cupper...

  11. Acoustic emission signal measurements in pressure vessel testing

    International Nuclear Information System (INIS)

    Peter, A.

    1984-01-01

    The number of acoustic emission events per plastically deformed unit of volume caused by artificial notches in real pressure vessels has been calculated taking into account reference voltage, distance between acoustic emission source and sensor as well as the effect of noise background. A test performed at a 100 m 3 gasholder verifies the theoretical considerations. (author)

  12. Interpretation of Strain Measurements on Nuclear Pressure Vessels

    DEFF Research Database (Denmark)

    Andersen, Svend Ib Smidt; Engbæk, Preben

    1980-01-01

    with a negligible zeroshift. However, deviations from linear behaviour are observed in several cases. This nonlinearity can be explained by friction (flange connections) or by gaps (concentrical nozzles) in certain regions, whereas local plastic deformations during the first pressure loadings of the vessel seem...

  13. 3-D high-frequency endovaginal ultrasound of female urethral complex and assessment of inter-observer reliability

    International Nuclear Information System (INIS)

    Wieczorek, A.P.; Wozniak, M.M.; Stankiewicz, A.; Santoro, G.A.; Bogusiewicz, M.; Rechberger, T.

    2012-01-01

    Objectives: Assessment of the urethral complex and defining its morphological characteristics with 3-dimensional endovaginal ultrasonography with the use of high frequency rotational 360° transducer. Defining inter-observer reliability of the performed measurements. Materials and methods: Twenty-four asymptomatic, nulliparous females (aged 18–55, mean 32 years) underwent high-frequency (12 MHz) endovaginal ultrasound with rotational 360° and automated 3D data acquisition (type 2050, B-K Medical, Herlev, Denmark). Measurements of the urethral thickness, width and length, bladder neck-symphysis distance, intramural part of the urethra as well as rhabdosphincter thickness, width and length were taken by three investigators. Descriptive statistics for continuous data was performed. The results were given as mean values with standard deviation. The relationships among different variables were assessed with ANOVA for repeated measures factors, as well as T-test for dependent samples. Intraclass correlation (ICC) was calculated for each parameter. Intra- and interobserver reliability was assessed. Statistical significance was assigned to a P value of 0.8) and good reliability for rhabdosphincter measurements (ICC > 0.6) between all three investigators. Conclusions: Advanced EVUS provides detailed information on anatomy and morphology of the female urethral complex. Our results show that 360° rotational transducer with automated 3D acquisition, currently routinely used for proctological scanning is suitable for the reliable assessment of the urethral complex and can be applied in a routine diagnostics of pelvic floor disturbances in females.

  14. Simultaneously Measured Interarm Blood Pressure Difference and Stroke: An Individual Participants Data Meta-Analysis.

    Science.gov (United States)

    Tomiyama, Hirofumi; Ohkuma, Toshiaki; Ninomiya, Toshiharu; Mastumoto, Chisa; Kario, Kazuomi; Hoshide, Satoshi; Kita, Yoshikuni; Inoguchi, Toyoshi; Maeda, Yasutaka; Kohara, Katsuhiko; Tabara, Yasuharu; Nakamura, Motoyuki; Ohkubo, Takayoshi; Watada, Hirotaka; Munakata, Masanori; Ohishi, Mitsuru; Ito, Norihisa; Nakamura, Michinari; Shoji, Tetsuo; Vlachopoulos, Charalambos; Yamashina, Akira

    2018-06-01

    We conducted individual participant data meta-analysis to examine the validity of interarm blood pressure difference in simultaneous measurement as a marker to identify subjects with ankle-brachial pressure index blood pressure difference >5 mm Hg as being associated with a significant odds ratio for the presence of ankle-brachial pressure index blood pressure difference >15 mm Hg was associated with a significant Cox stratified adjusted hazard ratio for subsequent stroke (hazard ratio, 2.42; 95% confidence interval, 1.27-4.60; P blood pressure differences, measured simultaneously in both arms, may be associated with vascular damage in the systemic arterial tree. These differences may be useful for identifying subjects with an ankle-brachial pressure index of blood pressure in both arms at the first visit. © 2018 American Heart Association, Inc.

  15. Laser-machined microcavities for simultaneous measurement of high-temperature and high-pressure.

    Science.gov (United States)

    Ran, Zengling; Liu, Shan; Liu, Qin; Huang, Ya; Bao, Haihong; Wang, Yanjun; Luo, Shucheng; Yang, Huiqin; Rao, Yunjiang

    2014-08-07

    Laser-machined microcavities for simultaneous measurement of high-temperature and high-pressure are demonstrated. These two cascaded microcavities are an air cavity and a composite cavity including a section of fiber and an air cavity. They are both placed into a pressure chamber inside a furnace to perform simultaneous pressure and high-temperature tests. The thermal and pressure coefficients of the short air cavity are ~0.0779 nm/°C and ~1.14 nm/MPa, respectively. The thermal and pressure coefficients of the composite cavity are ~32.3 nm/°C and ~24.4 nm/MPa, respectively. The sensor could be used to separate temperature and pressure due to their different thermal and pressure coefficients. The excellent feature of such a sensor head is that it can withstand high temperatures of up to 400 °C and achieve precise measurement of high-pressure under high temperature conditions.

  16. Measurement of intrahepatic pressure during radiofrequency ablation in porcine liver.

    Science.gov (United States)

    Kawamoto, Chiaki; Yamauchi, Atsushi; Baba, Yoko; Kaneko, Keiko; Yakabi, Koji

    2010-04-01

    To identify the most effective procedures to avoid increased intrahepatic pressure during radiofrequency ablation, we evaluated different ablation methods. Laparotomy was performed in 19 pigs. Intrahepatic pressure was monitored using an invasive blood pressure monitor. Radiofrequency ablation was performed as follows: single-step standard ablation; single-step at 30 W; single-step at 70 W; 4-step at 30 W; 8-step at 30 W; 8-step at 70 W; and cooled-tip. The array was fully deployed in single-step methods. In the multi-step methods, the array was gradually deployed in four or eight steps. With the cooled-tip, ablation was performed by increasing output by 10 W/min, starting at 40 W. Intrahepatic pressure was as follows: single-step standard ablation, 154.5 +/- 30.9 mmHg; single-step at 30 W, 34.2 +/- 20.0 mmHg; single-step at 70 W, 46.7 +/- 24.3 mmHg; 4-step at 30 W, 42.3 +/- 17.9 mmHg; 8-step at 30 W, 24.1 +/- 18.2 mmHg; 8-step at 70 W, 47.5 +/- 31.5 mmHg; and cooled-tip, 114.5 +/- 16.6 mmHg. The radiofrequency ablation-induced area was spherical with single-step standard ablation, 4-step at 30 W, and 8-step at 30 W. Conversely, the ablated area was irregular with single-step at 30 W, single-step at 70 W, and 8-step at 70 W. The ablation time was significantly shorter for the multi-step method than for the single-step method. Increased intrahepatic pressure could be controlled using multi-step methods. From the shapes of the ablation area, 30-W 8-step expansions appear to be most suitable for radiofrequency ablation.

  17. Comparison of sonourethrography and retrograde urethrography in the evaluation of anterior urethral strictures

    Directory of Open Access Journals (Sweden)

    N. Khan

    2004-06-01

    Full Text Available Radiographic retrograde urethrography (RUG has traditionally been the preferred technique used by urologists to image the anterior urethra. Since originally described by McAninch et aL in 1988, ultrasonic imaging of the urethra has evolved into a powerful and clinically useful tool for the accurate delineation of urethral pathology. However the posterior urethra cannot be assessed reliably using this technique. Sonourethrography has proved to be more accurate than conventional radiographic urethrography in measuring stricture length throughout the anterior urethra. The objective and purpose of this study was to assess the efficacy of sonourethrography in the evaluation of anterior urethral strictures and also to explain its many advantages over traditional imaging technique.

  18. High Resolution and Large Dynamic Range Resonant Pressure Sensor Based on Q-Factor Measurement

    Science.gov (United States)

    Gutierrez, Roman C. (Inventor); Stell, Christopher B. (Inventor); Tang, Tony K. (Inventor); Vorperian, Vatche (Inventor); Wilcox, Jaroslava (Inventor); Shcheglov, Kirill (Inventor); Kaiser, William J. (Inventor)

    2000-01-01

    A pressure sensor has a high degree of accuracy over a wide range of pressures. Using a pressure sensor relying upon resonant oscillations to determine pressure, a driving circuit drives such a pressure sensor at resonance and tracks resonant frequency and amplitude shifts with changes in pressure. Pressure changes affect the Q-factor of the resonating portion of the pressure sensor. Such Q-factor changes are detected by the driving/sensing circuit which in turn tracks the changes in resonant frequency to maintain the pressure sensor at resonance. Changes in the Q-factor are reflected in changes of amplitude of the resonating pressure sensor. In response, upon sensing the changes in the amplitude, the driving circuit changes the force or strength of the electrostatic driving signal to maintain the resonator at constant amplitude. The amplitude of the driving signals become a direct measure of the changes in pressure as the operating characteristics of the resonator give rise to a linear response curve for the amplitude of the driving signal. Pressure change resolution is on the order of 10(exp -6) torr over a range spanning from 7,600 torr to 10(exp -6) torr. No temperature compensation for the pressure sensor of the present invention is foreseen. Power requirements for the pressure sensor are generally minimal due to the low-loss mechanical design of the resonating pressure sensor and the simple control electronics.

  19. Nanocomposite-Based Microstructured Piezoresistive Pressure Sensors for Low-Pressure Measurement Range

    Directory of Open Access Journals (Sweden)

    Vasileios Mitrakos

    2018-01-01

    Full Text Available Piezoresistive pressure sensors capable of detecting ranges of low compressive stresses have been successfully fabricated and characterised. The 5.5 × 5 × 1.6 mm3 sensors consist of a planar aluminium top electrode and a microstructured bottom electrode containing a two-by-two array of truncated pyramids with a piezoresistive composite layer sandwiched in-between. The responses of two different piezocomposite materials, a Multiwalled Carbon Nanotube (MWCNT-elastomer composite and a Quantum Tunneling Composite (QTC, have been characterised as a function of applied pressure and effective contact area. The MWCNT piezoresistive composite-based sensor was able to detect pressures as low as 200 kPa. The QTC-based sensor was capable of detecting pressures as low as 50 kPa depending on the contact area of the bottom electrode. Such sensors could find useful applications requiring the detection of small compressive loads such as those encountered in haptic sensing or robotics.

  20. Proposal to Measure Hadron Scattering with a Gaseous High Pressure TPC for Neutrino Oscillation Measurements

    CERN Document Server

    Andreopoulos, C; Bordoni, S; Boyd, S; Brailsford, D; Brice, S; Catanesi, G; Chen-Wishart, Z; Denner, P; Dunne, P; Giganti, C; Gonzalez Diaz, D; Haigh, J; Hamacher-Baumann, P; Hallsjo, S; Hayato, Y; Irastorza, I; Jamieson, B; Kaboth, A; Korzenev, A; Kudenko, Y; Leyton, M; Luk, K-B; Ma, W; Mahn, K; Martini, M; McCauley, N; Mermod, P; Monroe, J; Mosel, U; Nichol, R; Nieves, J; Nonnenmacher, T; Nowak, J; Parker, W; Raaf, J; Rademacker, J; Radermacher, T; Radicioni, E; Roth, S; Saakyan, R; Sanchez, F; Sgalaberna, D; Shitov, Y; Sobczyk, J; Soler, F; Touramanis, C; Valder, S; Walding, J; Ward, M; Wascko, M; Weber, A; Yokoyama, M; Zalewska, A; Ziembicki, M

    2017-01-01

    We propose to perform new measurements of proton and pion scattering on argon using a prototype High Pressure gas Time Projection Chamber (HPTPC) detector, and by doing so to develop the physics case for, and the technological readiness of, an HPTPC as a neutrino detector for accelerator neutrino oscillation searches. The motivation for this work is to improve knowledge of final state interactions, in order to ultimately achieve 1-2% systematic error on neutrino-nucleus scattering for oscillation measurements at 0.6 GeV and 2.5 GeV neutrino energy, as required for the Charge-Parity (CP) violation sensitivity projections by the Hyper-Kamiokande experiment (Hyper-K) and the Deep Underground Neutrino Experiment (DUNE). The final state interaction uncertainties in neutrino-nucleus interactions dominate cross-section systematic errors, currently 5–10% at these energies, and therefore R&D is needed to explore new approaches to achieve this substantial improvement.

  1. Wireless contactless pressure measurement of an LC passive pressure sensor with a novel antenna for high-temperature applications

    International Nuclear Information System (INIS)

    Li Chen; Tan Qiu-Lin; Xue Chen-Yang; Zhang Wen-Dong; Li Yun-Zhi; Xiong Ji-Jun

    2015-01-01

    In this paper, a novel antenna is proposed for high-temperature testing, which can make the high-temperature pressure characteristics of a wireless passive ceramic pressure sensor demonstrated at up to a temperature of 600 °C. The design parameters of the antenna are similar to those of the sensor, which will increase the coupling strength between the sensor and testing antenna. The antenna is fabricated in thick film integrated technology, and the properties of the alumina ceramic and silver ensure the feasibility of the antenna in high-temperature environments. The sensor, coupled with the ceramic antenna, is investigated using a high-temperature pressure testing platform. The experimental measurement results show that the pressure signal in a harsh environment can be detected by the frequency diversity of the sensor. (paper)

  2. Surface pressure retrieval from SCIAMACHY measurements in the O2 A Band: validation of the measurements and sensitivity on aerosols

    Directory of Open Access Journals (Sweden)

    B. van Diedenhoven

    2005-01-01

    Full Text Available We perform surface pressure retrievals from cloud-free Oxygen A band measurements of SCIAMACHY. These retrievals can be well validated because surface pressure is a quantity that is, in general, accurately known from meteorological models. Therefore, surface pressure retrievals and their validation provide important insight into the quality of the instrument calibration. Furthermore, they can provide insight into retrievals which are affected by similar radiation transport processes, for example the retrieval of total columns of H2O, CO, CO2 and CH4. In our retrieval aerosols are neglected. Using synthetic measurements, it is shown that for low to moderate surface albedos this leads to an underestimation of the retrieved surface pressures. For high surface albedos this generally leads to an overestimation of the retrieved surface pressures. The surface pressures retrieved from the SCIAMACHY measurements indeed show this dependence on surface albedo, when compared to the corresponding pressures from a meteorological database. However, an offset of about 20 hPa was found, which can not be caused by neglecting aerosols in the retrieval. The same offset was found when comparing the retrieved surface pressures to those retrieved from co-located GOME Oxygen A band measurements. This implies a calibration error in the SCIAMACHY measurements. By adding an offset of 0.86% of the continuum reflectance at 756 nm to the SCIAMACHY reflectance measurements, this systematic bias vanishes.

  3. In situ high-pressure measurement of crystal solubility by using neutron diffraction

    Science.gov (United States)

    Chen, Ji; Hu, Qiwei; Fang, Leiming; He, Duanwei; Chen, Xiping; Xie, Lei; Chen, Bo; Li, Xin; Ni, Xiaolin; Fan, Cong; Liang, Akun

    2018-05-01

    Crystal solubility is one of the most important thermo-physical properties and plays a key role in industrial applications, fundamental science, and geoscientific research. However, high-pressure in situ measurements of crystal solubility remain very challenging. Here, we present a method involving high-pressure neutron diffraction for making high-precision in situ measurements of crystal solubility as a function of pressure over a wide range of pressures. For these experiments, we designed a piston-cylinder cell with a large chamber volume for high-pressure neutron diffraction. The solution pressures are continuously monitored in situ based on the equation of state of the sample crystal. The solubility at a high pressure can be obtained by applying a Rietveld quantitative multiphase analysis. To evaluate the proposed method, we measured the high-pressure solubility of NaCl in water up to 610 MPa. At a low pressure, the results are consistent with the previous results measured ex situ. At a higher pressure, more reliable data could be provided by using an in situ high-pressure neutron diffraction method.

  4. Primary care management of sexually transmitted urethritis in adolescent males.

    Science.gov (United States)

    Lindberg, Claire E

    2003-04-01

    To describe current knowledge about diagnosis, screening, and treatment of sexually transmitted urethritis among adolescent and young adult males. Current research, systematic reviews, consensus guidelines and the author's clinical experience. Urethritis, the most common sexually transmitted syndrome in young males, is most frequently caused by Chlamydia trachomatis and/or Neisseria gonorrhea. Symptoms include dysuria and penile discharge, although up to 50% of males are asymptomatic. Risky sexual behaviors and lack of access to healthcare increase incidence of this infection. Transmission to female partners can lead to pelvic inflammatory disease, infertility, and neonatal infection. Young males with urethritis must be treated as soon as diagnosis is established. Consensus guidelines exist for diagnosis and treatment of gonococcal and non-gonococcal urethritis. Careful patient education is necessary to ensure successful treatment. Prevention of repeat infections requires partner treatment and detailed education about safer sexual practices. Improved access to preventive services for young males should be a healthcare priority.

  5. A novel cannulation technique for difficult urethral catheterization

    Directory of Open Access Journals (Sweden)

    Mehmet Kaynar

    2016-03-01

    Full Text Available Introduction: To propose a novel cannulation technique for difficult urethral catheterization procedures. Technique: The sheath tip of an intravenous catheter is cut off, replaced to the needle tip and pushed through the distal drainage side hole to Foley catheter tip, and finally withdrawn for cannulation. In situations making urethral catheterization difficult, a guide wire is placed under direct vision. The modified Foley catheter is slid successfully over the guide wire from its distal end throughout the urethral passage into the bladder. Results: The modified Foley catheter was used successfully in our clinic in cases requiring difficult urethral catheterization. Conclusions: This easy and rapid modification of a Foley catheter may minimize the potential complications of blind catheter placement in standard catheterization.

  6. Patient knowledge of urethral stricture disease in a state sector ...

    African Journals Online (AJOL)

    M. Barnard

    2018-02-16

    Feb 16, 2018 ... Introduction: The knowledge urethral stricture patients in a developing country Specialist Clinic have ... A systematic review done by DeWalt et al. confirms that low literacy ... The questionnaire was translated into Afrikaans and.

  7. Contralateral Fracture of the Penis with Concomitant Urethral Injury ...

    African Journals Online (AJOL)

    ra

    2009-03-16

    Mar 16, 2009 ... 2, 2009. 103. 103-106. Case Report. Contralateral Fracture of the Penis with Concomitant. Urethral ... Examination revealed ecchymosis and swelling of the proximal shaft and ... of impotence due to infection and cavernosal.

  8. Hinged Transpubic Approach to Delayed Repair of Posterior Urethral

    African Journals Online (AJOL)

    ... to the management of one of the most challenging injuries of the lower urinary tract. ... This patient underwent a successful re-operation with full recovery. ... delayed repair of urethral distraction defects complicating pelvic fracture is feasible.

  9. Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots.

    Science.gov (United States)

    Acierno, Mark J; da Cunha, Anderson; Smith, Julie; Tully, Thomas N; Guzman, David Sanchez-Migallon; Serra, Verna; Mitchell, Mark A

    2008-11-15

    To determine the level of agreement between direct and indirect blood pressure measurements obtained from healthy Hispaniolan Amazon parrots (Amazona ventralis) anesthetized with isoflurane. Validation study. 16 healthy adult Hispaniolan Amazon parrots. Parrots were anesthetized, and a 26-gauge, 19-mm catheter was placed percutaneously in the superficial ulnar artery for direct measurement of systolic, mean, and diastolic arterial pressures. Indirect blood pressure measurements were obtained with a Doppler ultrasonic flow detector and an oscillometric unit. The Bland-Altman method was used to compare direct and indirect blood pressure values. There was substantial disagreement between direct systolic arterial blood pressure and indirect blood pressure measurements obtained with the Doppler detector from the wing (bias, 24 mm Hg; limits of agreement, -37 to 85 mm Hg) and from the leg (bias, 14 mm Hg; limits of agreement, -14 to 42 mm Hg). Attempts to obtain indirect blood pressure measurements with the oscillometric unit were unsuccessful. Results suggested that there was substantial disagreement between indirect blood pressure measurements obtained with a Doppler ultrasonic flow detector in anesthetized Hispaniolan Amazon parrots and directly measured systolic arterial blood pressure.

  10. Influence on Calculated Blood Pressure of Measurement Posture for the Development of Wearable Vital Sign Sensors

    Directory of Open Access Journals (Sweden)

    Shouhei Koyama

    2017-01-01

    Full Text Available We studied a wearable blood pressure sensor using a fiber Bragg grating (FBG sensor, which is a highly accurate strain sensor. This sensor is installed at the pulsation point of the human body to measure the pulse wave signal. A calibration curve is built that calculates the blood pressure by multivariate analysis using the pulse wave signal and a reference blood pressure measurement. However, if the measurement height of the FBG sensor is different from the reference measurement height, an error is included in the reference blood pressure. We verified the accuracy of the blood pressure calculation with respect to the measurement height difference and the posture of the subject. As the difference between the measurement height of the FBG sensor and the reference blood pressure measurement increased, the accuracy of the blood pressure calculation decreased. When the measurement height was identical and only posture was changed, good accuracy was achieved. In addition, when calibration curves were built using data measured in multiple postures, the blood pressure of each posture could be calculated from a single calibration curve. This will allow miniaturization of the necessary electronics of the sensor system, which is important for a wearable sensor.

  11. Arterial blood pressure measurement and pulse wave analysis—their role in enhancing cardiovascular assessment

    International Nuclear Information System (INIS)

    Avolio, Alberto P; Butlin, Mark; Walsh, Andrew

    2010-01-01

    The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blood pressure obtained from the brachial cuff. Although the measurement is taken in a peripheral limb, the values are generally assumed to reflect the pressure throughout the arterial tree in large conduit arteries. Since the arterial pressure pulse becomes modified as it travels away from the heart towards the periphery, this is generally true for mean and diastolic pressure, but not for systolic pressure, and so pulse pressure. The relationship between central and peripheral pulse pressure depends on propagation characteristics of arteries. Hence, while the sphygmomanometer gives values of two single points on the pressure wave (systolic and diastolic pressure), there is additional information that can be obtained from the time-varying pulse waveform that enables an improved quantification of the systolic load on the heart and other central organs. This topical review will assess techniques of pressure measurement that relate to the use of the cuff sphygmomanometer and to the non-invasive registration and analysis of the peripheral and central arterial pressure waveform. Improved assessment of cardiovascular function in relation to treatment and management of high blood pressure will result from future developments in the indirect measurement of arterial blood pressure that involve the conventional cuff sphygmomanometer with the addition of information derived from the peripheral arterial pulse. (topical review)

  12. THE ROLE OF OPTICAL INTERNAL URETHROTOMY FOR MALE URETHRAL STRICTURE

    Directory of Open Access Journals (Sweden)

    Ekrem Akdeniz

    2016-04-01

    Full Text Available Introduction:Urethral stricture is characterized by decrease in urethral flow severe enough to cause acute urinary retention. Urethral strictures may develop after traumas to urethral epithelium and/or corpus spongiosum. Complication rates due to untreated urethral stricture are very high. Although various treatment methods have been described, the second most common method after urethral dilation in practice is cold-knife internal urethrotomy. The purpose of this study is to evaluate data of patients who were treated with internal urethrotomy in our clinic. Methods:This study included patients who were treated with internal urethrotomy due to internal stricture between January 2011 and May 2015. Demographic, clinical, radiological, uroflowmetric (maximum and mean urine flow rate and operative datas of the patients were retrospectively evaluated and recorded. Results:This study included 155 patients with a mean (±standard deviation age of 71.70 (±13.7. Etiologically the most common reason was urological surgical procedures (67% and the most common stricture was seen at bulbomembranous urethra region (85.2%. Mean length of stricture was 5.4±2.4mm. Mean duration to remove the catheter was 1.8±1.3 days. Regional anesthesia was used in 67.7% of the patients. Our success rate was 78,1%. Comparison of maximum and mean urine flow rates pre and postoperatively revealed significant increases postoperatively. Conclusion:Internal urethrotomy is a first line treatment method for urethral strictures because it is easily applied, has a low complication rate, and can be applied with local aenesthesia in high risk patients who are unable to take general anesthesia. Although recurrence rate is high, repeatability is its greatest advantage and it causes significant relief in patients with urethral strictures, but it must be kept in mind that definitive treatment is urethroplasty.

  13. Simple urethral dilatation, endoscopic urethrotomy, and urethroplasty for urethral stricture disease in adult men.

    Science.gov (United States)

    Wong, Susan S W; Aboumarzouk, Omar M; Narahari, Radhakrishna; O'Riordan, Anna; Pickard, Robert

    2012-12-12

    Strictures of the urethra are the most common cause of obstructed micturition in younger men and frequently recur after initial treatment. Standard treatment comprises internal widening of the strictured area by simple dilatation or by telescope-guided internal cutting (optical urethrotomy), but these interventions are associated with a high failure rate requiring repeated treatment. The alternative option of open urethroplasty whereby the urethral lumen is permanently widened by removal or grafting of the strictured segment is less likely to fail but requires greater expertise. Findings of Improved choice of graft material and shortened hospital stay suggest that urethroplasty may be under utilised. The extent and quality of evidence guiding treatment choice for this condition are uncertain.   To determine which is the best surgical treatment for male urethral stricture disease taking into account relative efficacy, adverse event rates and cost-effectiveness.   We searched the Cochrane Incontinence Group Specialised Register (searched 21 June 2012), CENTRAL (2012, Issue 6), MEDLINE (January 1946 to week 2 June 2012), EMBASE (January 1980 to week 25 2012), OpenSIGLE (searched 26 June 2012), clinical trials registries and reference lists of relevant articles. We included publications reporting data from randomised or quasi-randomised controlled trials comparing the effectiveness of dilatation, urethrotomy and urethroplasty in the treatment of adult men with urethral stricture disease. Two authors evaluated trials for appropriateness for inclusion and methodological quality. Data extraction was performed using predetermined criteria. Analyses were carried out using the Cochrane Review Manager software (RevMan 5). Two randomised trials were identified. One trial compared the outcomes of surgical urethral dilatation and optical urethrotomy in 210 adult men with urethral stricture disease. No significant difference was found in the proportion of men being

  14. Contact pressure measurement in hand tool evaluation studies

    NARCIS (Netherlands)

    Kuijt-Evers, L.F.M.; Bosch, T.

    2006-01-01

    In hand tool evaluation studies, several objective measurements are used. Grip force distribution and grip force are important as they give feedback about the force which has to be performed with the hand on the handle. A measurement technique -which is related to grip force measurement- is contact

  15. High-resolution thermal expansion measurements under helium-gas pressure

    Science.gov (United States)

    Manna, Rudra Sekhar; Wolf, Bernd; de Souza, Mariano; Lang, Michael

    2012-08-01

    We report on the realization of a capacitive dilatometer, designed for high-resolution measurements of length changes of a material for temperatures 1.4 K ⩽ T ⩽ 300 K and hydrostatic pressure P ⩽ 250 MPa. Helium (4He) is used as a pressure-transmitting medium, ensuring hydrostatic-pressure conditions. Special emphasis has been given to guarantee, to a good approximation, constant-pressure conditions during temperature sweeps. The performance of the dilatometer is demonstrated by measurements of the coefficient of thermal expansion at pressures P ≃ 0.1 MPa (ambient pressure) and 104 MPa on a single crystal of azurite, Cu3(CO3)2(OH)2, a quasi-one-dimensional spin S = 1/2 Heisenberg antiferromagnet. The results indicate a strong effect of pressure on the magnetic interactions in this system.

  16. The position of the arm during blood pressure measurement in sitting position.

    NARCIS (Netherlands)

    Adiyaman, A.; Verhoeff, R.; Lenders, J.W.M.; Deinum, J.; Thien, Th.

    2006-01-01

    OBJECTIVE: Determining the influence of the position of the arm on blood pressure measurement in the sitting position. METHODS: Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in

  17. Recommendations for blood pressure measuring devices for office/clinic use in low resource settings

    NARCIS (Netherlands)

    Parati, G.; Mendis, S.; Abegunde, D.; Asmar, R.; Mieke, S.; Murray, A.; Shengelia, B.; Steenvoorden, G.; Montfrans, G. van; O'Brien, E.

    2005-01-01

    This paper, which summarizes the conclusions of a WHO Expert meeting, is aimed at proposing indications to develop technical specifications for an accurate and affordable blood pressure measuring device for office/ clinic use in low resource settings. Blood pressure measuring devices to be used in

  18. Measuring the collateral network pressure to minimize paraplegia risk in thoracoabdominal aneurysm resection.

    Science.gov (United States)

    Etz, Christian D; Zoli, Stefano; Bischoff, Moritz S; Bodian, Carol; Di Luozzo, Gabriele; Griepp, Randall B

    2010-12-01

    To minimize paraplegia during thoracoabdominal aortic aneurysm repair, the concept of the collateral network was developed. That is, spinal cord perfusion is provided by an interconnecting complex of vessels in the intraspinal, paraspinous, and epidural space and in the paravertebral muscles, including intercostal and lumbar segmental as well as subclavian and hypogastric arteries. Collateral network pressure was measured with a catheter in the distal end of a ligated segmental artery in pigs and human beings. In the pig, collateral network pressure was 75% of the simultaneous mean aortic pressure. With complete segmental arterial ligation, it fell to 27% of baseline, recovering to 40% at 24 hours and 90% at 120 hours. Spinal cord injury occurred in approximately 50% of animals. When all segmental arteries were taken in 2 stages a week apart, collateral network pressure fell only to 50% to 70% of baseline, and spinal cord injury was rare. In human beings, baseline collateral network pressure also was 75% of mean aortic pressure, fell in proportion to the number of segmental arteries ligated, and began recovery within 24 hours. Collateral network pressure was lower with nonpulsatile distal bypass than with pulsatile perfusion. After subtraction of a measure of spinal cord outflow pressure (cerebrospinal fluid pressure or central venous pressure), collateral network pressure provides a clinically useful estimate of spinal cord perfusion pressure. Copyright © 2010. Published by Mosby, Inc.

  19. A viscosity measurement during the high pressure phase transition in triolein

    International Nuclear Information System (INIS)

    Siegoczynski, R M; Rostocki, A J; Kielczynski, P; Szalewski, M

    2008-01-01

    The high-pressure properties of triolein, a subject of extensive research at the Faculty of Physics of Warsaw University of Technology (WUT) have been enhanced by the results of viscosity measurement within the pressure range up to 0.8 GPa. For the measurement the authors have adopted a new ultrasonic method based on Bleustein-Gulyaev waves, successfully developed earlier for the low pressures in the Section of Acoustoelectronics of the Institute of Fundamental Technological Research. The measurements have shown: 1. Exponential rise of viscosity with pressure up to 0.5 GPa. 2. Extraordinary increment of viscosity at constant pressure during phase transition. 3. Further exponential rise of viscosity with pressure of the high-pressure phase of triolein. 4. The pressure exponents of the viscosity of both phases were different (the high-pressure phase had much smaller exponent). 5. The decomposition of the high pressure phase due to the slow decompression have shown very large hysteresis of viscosity on pressure dependence

  20. The measurement for level of marine high-temperature and high-pressure vessels

    International Nuclear Information System (INIS)

    Lin Jie.

    1986-01-01

    The various error factors in measurement for level of marine high-temperature and high-pressure vessels are anslysed. The measuring method of error self compensation and its simplification for land use are shown

  1. Dorsal onlay vaginal graft urethroplasty for female urethral stricture

    Directory of Open Access Journals (Sweden)

    Manmeet Singh

    2013-01-01

    Full Text Available Introduction: Female urethral stricture is an underdiagnosed and overlooked cause of female bladder outlet obstruction. The possible etiologies may be infection, prior dilation, difficult catheterization with subsequent fibrosis, urethral surgery, trauma, or idiopathic. We present our technique and results of dorsal onlay full thickness vaginal graft urethroplasty for female urethral stricture. Materials and Methods: A retrospective review was performed on 16 female patients with mid-urethral stricture who underwent dorsal onlay vaginal graft urethroplasty from January 2007 to June 2011.Of these, 13 patients had previously undergone multiple Hegar dilatations, three had previous internal urethrotomies. The preoperative work up included detailed voiding history, local examination, uroflowmetry, calibration, and micturating cystourethrogram. Results: All patients had mid-urethral stricture. Mean age was 47.5 years. Mean Q max improved from 6.2 to 27.6 ml/s. Mean residual volume decreased from 160 to 20 ml. Mean duration of follow-up was 24.5 months (6 months to 3 years. Only one patient required self-calibration for 6 months after which her stricture stabilized. None of the patient was incontinent. Conclusion: Dorsal vaginal onlay graft urethroplasty could be considered as an effective way to treat female urethral stricture.

  2. Urethral obstruction from dislodged bladder Diverticulum stones: a case report

    Directory of Open Access Journals (Sweden)

    Okeke Linus I

    2012-11-01

    Full Text Available Abstract Background Secondary urethral stone although rare, commonly arises from the kidneys, bladder or are seen in patients with urethral stricture. These stones are either found in the posterior or anterior urethra and do result in acute urinary retention. We report urethral obstruction from dislodged bladder diverticulum stones. This to our knowledge is the first report from Nigeria and in English literature. Case presentation A 69 year old, male, Nigerian with clinical and radiological features of acute urinary retention, benign prostate enlargement and bladder diverticulum. He had a transurethral resection of the prostate (TURP and was lost to follow up. He re-presented with retained urethral catheter of 4months duration. The catheter was removed but attempt at re-passing the catheter failed and a suprapubic cystostomy was performed. Clinical examination and plain radiograph of the penis confirmed anterior and posterior urethral stones. He had meatotomy and antegrade manual stone extraction with no urethra injury. Conclusions Urethral obstruction can result from inadequate treatment of patient with benign prostate enlargement and bladder diverticulum stones. Surgeons in resource limited environment should be conversant with transurethral resection of the prostate and cystolithotripsy or open prostatectomy and diverticulectomy.

  3. Urethral and periurethral dosimetry in prostate brachytherapy: is there a convenient surrogate?

    International Nuclear Information System (INIS)

    Bucci, Joseph; Spadinger, Ingrid; Hilts, Michelle; Sidhu, Sabeena; Smith, Clarke; Keyes, Mira; Morris, W. James

    2002-01-01

    Purpose: To assess and compare two models for a surrogate urethra to be used for postimplant dosimetry in prostate brachytherapy. Methods and Materials: Twenty men with a urinary catheter present at the time of postimplant computed tomographic imaging were studied. Urethral and periurethral volumes were defined as 5-mm and 10-mm diameter volumes, respectively. Three contours of each were used: one contour of the true urethra (and periurethra), and two surrogate models. The true volumes were centered on the catheter center. One surrogate model used volumes centered on the geometrical center of each prostate contour (centered surrogate). The other surrogate model was based on the average deviation of the true urethra from a reference line through the geometrical center of the axial midplane of the prostate (deviated surrogate). Maximum point doses and the D 10 , D 25 , D 50 , D 90 , V 100 , V 120 , and V 150 of the true and surrogate volumes were measured and compared (D n is the minimum dose [Gy] received by n% of the structure, and V m is the volume [%] of the structure that received m% of the prescribed dose) as well as the distances between the surrogate urethras and the true urethra. Results: Doses determined from both surrogate urethral and periurethral volumes were in good agreement with the true urethral and periurethral doses except in the superior third of the gland. The deviated surrogate provided a physically superior likeness to the true urethra. Certain dose-volume histogram (DVH)-based parameters could also be predicted reasonably well on the basis of the surrogates. Correlation coefficients ≥0.85 were seen for D 25 , D 50 , V 100 , V 120 , and V 150 for both models. All the other parameters had correlation coefficients in the range of 0.73 - 0.85. Conclusions: Both surrogate models predicted true urethral dosimetry reasonably well. It is recommended that the simpler deviated surrogate would be a more suitable surrogate for routine clinical practice

  4. Comparison of two different methods for urethral lengthening in female to male (metoidioplasty) surgery.

    Science.gov (United States)

    Djordjevic, Miroslav L; Bizic, Marta R

    2013-05-01

    Metoidioplasty presents one of the variants of phalloplasty in female transsexuals. Urethral lengthening is the most difficult part in this surgery and poses many challenges. We evaluated 207 patients who underwent metoidioplasty, aiming to compare two different surgical techniques of urethral lengthening, postoperative results, and complications. The study encompassed a total of 207 patients, aged from 18 to 62 years, who underwent single stage metoidioplasty between September 2002 and July 2011. The procedure included lengthening and straightening of the clitoris, urethral reconstruction, and scrotoplasty with implantation of testicular prostheses. Buccal mucosa graft was used in all cases for dorsal urethral plate formation and joined with one of the two different flaps: I-longitudinal dorsal clitoral skin flap (49 patients) and II-labia minora flap (158 patients). Results were analyzed using Z-test to evaluate the statistical difference between the two approaches. Also, postoperative questionnaire was used, which included questions on functioning and esthetical appearance of participating subjects as well as overall satisfaction. The median follow-up was 39 months (ranged 12-116 months). The total length of reconstructed urethra was measured during surgery in both groups. It ranged from 9.1 to 12.3 cm (median 9.5) in group I and from 9.4 to 14.2 cm (median 10.8) in group II. Voiding while standing was significantly better in group II (93%) than in group I (87.82%) (P lengthening confirmed combined buccal mucosa graft and labia minora flap as a method of choice for urethroplasty in metoidioplasty, minimizing postoperative complications. © 2013 International Society for Sexual Medicine.

  5. Persistent increase in the incidence of acute male urethritis diagnosed in general practices in France

    Science.gov (United States)

    Massari, Véronique; Dorléans, Yves; Flahault, Antoine

    2006-01-01

    Background At-risk sexual behaviour seems to have increased in Europe, possibly due to the reassuring efficacy of highly active antiretroviral treatments. Aim To follow, from 1990 to 2003, in France, the trends in the incidence of acute male urethritis diagnosed in general practice, a marker of at-risk sexual behaviour. Design of study Electronic disease surveillance. Setting General practices located all over mainland France. Method The GPs of the French Sentinelles network reported, via online computer systems, the acute urethritis cases they diagnosed, and for each case the characteristics of the patients. Results After a striking decrease between 1990 and 1995 from 460 per 100 000 men aged 15–64 years (95% confidence interval [CI] = 390 to 520) to 180 (95% CI = 150 to 200), when antiretroviral drugs became available on the French market, the incidence of acute male urethritis stopped decreasing. Between 1996 and 2003, it may have risen again from 190 per 100 000 men (95% CI = 160 to 210) to 325 per 100 000 men (95% CI = 280 to 370) aged 15–64 years. The percentage of homosexual/bisexual men among the cases reported was higher than in the general population (10% versus 4%, Purethritis, shows that the sexual health of men has worsened in France, and calls for urgent new preventive measures. PMID:16464324

  6. The Efficacy of Bulbar Urethral Mobilization for Anastomotic Anterior Urethroplasty in a Case With Recurrent Anterior Urethral Stricture

    Directory of Open Access Journals (Sweden)

    Shinji Fukui

    2014-05-01

    Full Text Available A 2-month-old boy was diagnosed with febrile urinary tract infection. Voiding cystourethrography showed bulbar and anterior urethral strictures, and endoscopic internal urethrotomy was performed. He developed febrile urinary tract infection again and revealed the recurrence of the anterior urethral stricture. Consequently, endoscopic internal urethrotomy was performed 4 times. Because the anterior urethral stricture had not improved, he was referred to us. Anterior urethroplasty was performed when he was 5 years. After excision of the scarred portions of the urethra, the defect of the urethra was 20 mm. Transperineal bulbar urethral mobilization was performed, and a single-stage end-to-end anterior urethroplasty without tension could be performed simultaneously.

  7. A misleading urethral smear with polymorphonuclear leucocytes and intracellular diplococci; case report of urethritis caused by Neisseria meningitidis.

    Science.gov (United States)

    Genders, R E; Spitaels, D; Jansen, C L; van den Akker, Th W; Quint, K D

    2013-12-01

    The primary pathogens found in men with urethritis are Chlamydia trachomatis and Neisseria gonorrhoeae. Rapid diagnosis of N. gonorrhoeae infection can be made based on a Gram- or methylene blue-stained urethral smear. We describe a case of a man with purulent penile discharge, in which microscopic examination led to the presumptive diagnosis of gonorrhoea. A nucleic acid amplification test was negative for N. gonorrhoeae but positive for C. trachomatis. Culture showed Gram-negative diplococci which were identified as Neisseria meningitidis. N. meningitidis can be sporadically pathogenic in the genito-urinary tract and mimicks gonococcal urethritis, and appears identical by microscopy. When a gonococcal urethritis is suspected based on clinical signs and microscopic examination, but investigatory tests cannot confirm the diagnosis, a N. meningitidis infection should be considered.

  8. Arterial pressure measurement: Is the envelope curve of the oscillometric method influenced by arterial stiffness?

    International Nuclear Information System (INIS)

    Gelido, G; Angiletta, S; Pujalte, A; Quiroga, P; Cornes, P; Craiem, D

    2007-01-01

    Measurement of peripheral arterial pressure using the oscillometric method is commonly used by professionals as well as by patients in their homes. This non invasive automatic method is fast, efficient and the required equipment is affordable with a low cost. The measurement method consists of obtaining parameters from a calibrated decreasing curve that is modulated by heart beats witch appear when arterial pressure reaches the cuff pressure. Diastolic, mean and systolic pressures are obtained calculating particular instants from the heart beats envelope curve. In this article we analyze the envelope of this amplified curve to find out if its morphology is related to arterial stiffness in patients. We found, in 33 volunteers, that the envelope waveform width correlates to systolic pressure (r=0.4, p<0.05), to pulse pressure (r=0.6, p<0.05) and to pulse pressure normalized to systolic pressure (r=0.6, p<0.05). We believe that the morphology of the heart beats envelope curve obtained with the oscillometric method for peripheral pressure measurement depends on arterial stiffness and can be used to enhance pressure measurements

  9. Air Flow and Pressure Drop Measurements Across Porous Oxides

    Science.gov (United States)

    Fox, Dennis S.; Cuy, Michael D.; Werner, Roger A.

    2008-01-01

    This report summarizes the results of air flow tests across eight porous, open cell ceramic oxide samples. During ceramic specimen processing, the porosity was formed using the sacrificial template technique, with two different sizes of polystyrene beads used for the template. The samples were initially supplied with thicknesses ranging from 0.14 to 0.20 in. (0.35 to 0.50 cm) and nonuniform backside morphology (some areas dense, some porous). Samples were therefore ground to a thickness of 0.12 to 0.14 in. (0.30 to 0.35 cm) using dry 120 grit SiC paper. Pressure drop versus air flow is reported. Comparisons of samples with thickness variations are made, as are pressure drop estimates. As the density of the ceramic material increases the maximum corrected flow decreases rapidly. Future sample sets should be supplied with samples of similar thickness and having uniform surface morphology. This would allow a more consistent determination of air flow versus processing parameters and the resulting porosity size and distribution.

  10. Differential pressure distribution measurement for the development of insect-sized wings

    International Nuclear Information System (INIS)

    Takahashi, Hidetoshi; Matsumoto, Kiyoshi; Shimoyama, Isao

    2013-01-01

    This paper reports on the measurement of the differential pressure distribution over a flat, thin wing using a micro-electro-mechanical systems sensor. Sensors featuring a piezoresistive cantilever were attached to a polyimide/Cu wing. Because the weight of the cantilever element was less than 10 ng, the sensor can measure the differential pressure without interference from inertial forces, such as wing flapping motions. The dimensions of the sensor chips and the wing were 1.0 mm × 1.0 mm × 0.3 mm and 100 mm × 30 mm × 1 mm, respectively. The differential pressure distribution along the wing's chord direction was measured in a wind tunnel at an air velocity of 4.0 m s –1 by changing the angle of attack. It was confirmed that the pressure coefficient calculated by the measured differential pressure distribution was similar to the value measured by a load cell. (paper)

  11. Endoscopic removal of a proximal urethral stent using a holmium laser: Case report and literature review

    Directory of Open Access Journals (Sweden)

    Francisco Botelho

    2012-01-01

    Full Text Available Urethral stents were initially developed for the management of urethral strictures and obstructive voiding disorders in select patients. Urethral stent complications are common and may require stent explantation, which is often quite challenging. We present our experience with endoscopic removal of an encrusted UroLume proximal urethral stent in a 72-year-old male using a holmium laser. The literature on various management options and outcomes for urethral stent removal is reviewed. Endoscopic removal of proximal urethral stents is feasible and safe and should be considered as the primary treatment option in patients requiring stent extraction.

  12. Detection of small-amplitude periodic surface pressure fluctuation by pressure-sensitive paint measurements using frequency-domain methods

    Science.gov (United States)

    Noda, Takahiro; Nakakita, Kazuyki; Wakahara, Masaki; Kameda, Masaharu

    2018-06-01

    Image measurement using pressure-sensitive paint (PSP) is an effective tool for analyzing the unsteady pressure field on the surface of a body in a low-speed air flow, which is associated with wind noise. In this study, the surface pressure fluctuation due to the tonal trailing edge (TE) noise for a two-dimensional NACA 0012 airfoil was quantitatively detected using a porous anodized aluminum PSP (AA-PSP). The emission from the PSP upon illumination by a blue laser diode was captured using a 12-bit high-speed complementary metal-oxide-semiconductor (CMOS) camera. The intensities of the captured images were converted to pressures using a standard intensity-based method. Three image-processing methods based on the fast Fourier transform (FFT) were tested to determine their efficiency in improving the signal-to-noise ratio (SNR) of the unsteady PSP data. In addition to two fundamental FFT techniques (the full data and ensemble averaging FFTs), a technique using the coherent output power (COP), which involves the cross correlation between the PSP data and the signal measured using a pointwise sound-level meter, was tested. Preliminary tests indicated that random photon shot noise dominates the intensity fluctuations in the captured PSP emissions above 200 Hz. Pressure fluctuations associated with the TE noise, whose dominant frequency is approximately 940 Hz, were successfully measured by analyzing 40,960 sequential PSP images recorded at 10 kfps. Quantitative validation using the power spectrum indicates that the COP technique is the most effective method of identification of the pressure fluctuation directly related to TE noise. It is possible to distinguish power differences with a resolution of 10 Pa^2 (4 Pa in amplitude) when the COP was employed without use of another wind-off data. This resolution cannot be achieved by the ensemble averaging FFT because of an insufficient elimination of the background noise.

  13. Flexible Piezoelectric-Induced Pressure Sensors for Static Measurements Based on Nanowires/Graphene Heterostructures.

    Science.gov (United States)

    Chen, Zefeng; Wang, Zhao; Li, Xinming; Lin, Yuxuan; Luo, Ningqi; Long, Mingzhu; Zhao, Ni; Xu, Jian-Bin

    2017-05-23

    The piezoelectric effect is widely applied in pressure sensors for the detection of dynamic signals. However, these piezoelectric-induced pressure sensors have challenges in measuring static signals that are based on the transient flow of electrons in an external load as driven by the piezopotential arisen from dynamic stress. Here, we present a pressure sensor with nanowires/graphene heterostructures for static measurements based on the synergistic mechanisms between strain-induced polarization charges in piezoelectric nanowires and the caused change of carrier scattering in graphene. Compared to the conventional piezoelectric nanowire or graphene pressure sensors, this sensor is capable of measuring static pressures with a sensitivity of up to 9.4 × 10 -3 kPa -1 and a fast response time down to 5-7 ms. This demonstration of pressure sensors shows great potential in the applications of electronic skin and wearable devices.

  14. Transurethral resection of fibrotic scar tissue combined with temporary urethral stent placement for patients with in anterior urethral stricture

    Directory of Open Access Journals (Sweden)

    Cheol Yong Yoon

    2014-08-01

    Full Text Available Introduction Fibrotic scar formation is a main cause of recurrent urethral stricture after initial management with direct vision internal urethrotomy (DVIU. In the present study, we devised a new technique of combined the transurethral resection of fibrotic scar tissue and temporary urethral stenting, using a thermo-expandable urethral stent (MemokathTM 044TW in patients with anterior urethral stricture. Materials and Methods As a first step, multiple incisions were made around stricture site with cold-cutting knife and Collins knife electrode to release a stricture band. Fibrotic tissue was then resected with a 13Fr pediatric resectoscope before deployment of a MemokathTM 044TW stent (40 – 60mm on a pre-mounted sheath using 0° cystoscopy. Stents were removed within 12 months after initial placement. Results We performed this technique on 11 consecutive patients with initial (n = 4 and recurrent (n = 7 anterior urethral stricture (April 2009 – February 2013. At 18.9 months of mean follow-up (12-34 months, mean Qmax (7.8±3.9ml/sec vs 16.8 ± 4.8ml/sec, p < 0.001, IPSS (20.7 vs 12.5, p = 0.001 , and QoL score (4.7 vs 2.2, p < 0.001 were significantly improved. There were no significant procedure-related complications except two cases of tissue ingrowth at the edge of stent, which were amenable by transurethral resection. In 7 patients, an average 1.4 times (1-5 times of palliative urethral dilatation was carried out and no patients underwent open surgical urethroplasty during the follow-up period. Conclusion Combined transurethral resection and temporary urethral stenting is a effective therapeutic option for anterior urethral stricture. Further investigations to determine the long-term effects, and safety profile of this new technique are warranted.

  15. Calibrating airborne measurements of airspeed, pressure and temperature using a Doppler laser air-motion sensor

    Directory of Open Access Journals (Sweden)

    W. A. Cooper

    2014-09-01

    Full Text Available A new laser air-motion sensor measures the true airspeed with a standard uncertainty of less than 0.1 m s−1 and so reduces uncertainty in the measured component of the relative wind along the longitudinal axis of the aircraft to about the same level. The calculated pressure expected from that airspeed at the inlet of a pitot tube then provides a basis for calibrating the measurements of dynamic and static pressure, reducing standard uncertainty in those measurements to less than 0.3 hPa and the precision applicable to steady flight conditions to about 0.1 hPa. These improved measurements of pressure, combined with high-resolution measurements of geometric altitude from the global positioning system, then indicate (via integrations of the hydrostatic equation during climbs and descents that the offset and uncertainty in temperature measurement for one research aircraft are +0.3 ± 0.3 °C. For airspeed, pressure and temperature, these are significant reductions in uncertainty vs. those obtained from calibrations using standard techniques. Finally, it is shown that although the initial calibration of the measured static and dynamic pressures requires a measured temperature, once calibrated these measured pressures and the measurement of airspeed from the new laser air-motion sensor provide a measurement of temperature that does not depend on any other temperature sensor.

  16. Intracochlear pressure measurements in scala media inform models of cochlear mechanics

    Science.gov (United States)

    Kale, Sushrut; Olson, Elizabeth S.

    2015-12-01

    In the classic view of cochlear mechanics, the cochlea is comprised of two identical fluid chambers separated by the cochlear partition (CP). In this view the traveling wave pressures in the two chambers mirror each other; they are equal in magnitude and opposite in phase. A fast pressure mode adds approximately uniformly. More recent models of cochlear mechanics take into account the structural complexity of the CP and the resulting additional mechanical modes would lead to distinct (non-symmetric) patterns of pressure and motion on the two sides of the CP. However, there was little to no physiological data that explored these predictions. To this aim, we measured intracochlear fluid pressure in scala media (SM), including measurements close to the sensory tissue, using miniaturized pressure sensors (˜ 80 μm outer diameter). Measurements were made in-vivo from the basal cochlear turn in gerbils. SM pressure was measured at two longitudinal locations in different preparations. In a subset of the experiments SM and ST (scala tympani) pressures were measured at the same longitudinal location. Traveling wave pressures were observed in both SM and ST, and showed the relative phase predicted by the classical theory. In addition, SM pressure showed spatial variations that had not been observed in ST, which points to a relatively complex CP motion on the SM side. These data both underscore the first-order validity of the classic cochlear traveling wave model, and open a new view to CP mechanics.

  17. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.

    Science.gov (United States)

    Gholamhosseini, Hamid; Meintjes, Andries; Baig, Mirza; Linden, Maria

    2016-01-01

    The increasing availability of low cost and easy to use personalized medical monitoring devices has opened the door for new and innovative methods of health monitoring to emerge. Cuff-less and continuous methods of measuring blood pressure are particularly attractive as blood pressure is one of the most important measurements of long term cardiovascular health. Current methods of noninvasive blood pressure measurement are based on inflation and deflation of a cuff with some effects on arteries where blood pressure is being measured. This inflation can also cause patient discomfort and alter the measurement results. In this work, a mobile application was developed to collate the PhotoPlethysmoGramm (PPG) waveform provided by a pulse oximeter and the electrocardiogram (ECG) for calculating the pulse transit time. This information is then indirectly related to the user's systolic blood pressure. The developed application successfully connects to the PPG and ECG monitoring devices using Bluetooth wireless connection and stores the data onto an online server. The pulse transit time is estimated in real time and the user's systolic blood pressure can be estimated after the system has been calibrated. The synchronization between the two devices was found to pose a challenge to this method of continuous blood pressure monitoring. However, the implemented continuous blood pressure monitoring system effectively serves as a proof of concept. This combined with the massive benefits that an accurate and robust continuous blood pressure monitoring system would provide indicates that it is certainly worthwhile to further develop this system.

  18. Differential Intracochlear Sound Pressure Measurements in Human Temporal Bones with an Off-the-Shelf Sensor

    Directory of Open Access Journals (Sweden)

    Martin Grossöhmichen

    2016-01-01

    Full Text Available The standard method to determine the output level of acoustic and mechanical stimulation to the inner ear is measurement of vibration response of the stapes in human cadaveric temporal bones (TBs by laser Doppler vibrometry. However, this method is reliable only if the intact ossicular chain is stimulated. For other stimulation modes an alternative method is needed. The differential intracochlear sound pressure between scala vestibuli (SV and scala tympani (ST is assumed to correlate with excitation. Using a custom-made pressure sensor it has been successfully measured and used to determine the output level of acoustic and mechanical stimulation. To make this method generally accessible, an off-the-shelf pressure sensor (Samba Preclin 420 LP, Samba Sensors was tested here for intracochlear sound pressure measurements. During acoustic stimulation, intracochlear sound pressures were simultaneously measurable in SV and ST between 0.1 and 8 kHz with sufficient signal-to-noise ratios with this sensor. The pressure differences were comparable to results obtained with custom-made sensors. Our results demonstrated that the pressure sensor Samba Preclin 420 LP is usable for measurements of intracochlear sound pressures in SV and ST and for the determination of differential intracochlear sound pressures.

  19. Clinical comparison of automatic, noninvasive measurements of blood pressure in the forearm and upper arm.

    Science.gov (United States)

    Schell, Kathleen; Bradley, Elisabeth; Bucher, Linda; Seckel, Maureen; Lyons, Denise; Wakai, Sandra; Bartell, Deborah; Carson, Elizabeth; Chichester, Melanie; Foraker, Teresa; Simpson, Kathleen

    2005-05-01

    When the upper arm (area from shoulder to elbow) is inaccessible and/or a standard-sized blood pressure cuff does not fit, some healthcare workers use the forearm to measure blood pressure. To compare automatic noninvasive measurements of blood pressure in the upper arm and forearm. A descriptive, correlational comparison study was conducted in the emergency department of a 1071-bed teaching hospital. Subjects were 204 English-speaking patients 6 to 91 years old in medically stable condition who had entered the department on foot or by wheelchair and who had no exclusions to using their left upper extremity. A Welch Allyn Vital Signs 420 series monitor was used to measure blood pressure in the left upper arm and forearm with the subject seated and the upper arm or forearm at heart level. Pearson r correlation coefficients between measurements in the upper arm and forearm were 0.88 for systolic blood pressure and 0.76 for diastolic blood pressure (P upper arm and forearm differed significantly (t = 2.07, P = .04). A Bland-Altman analysis indicated that the distances between the mean values and the limits of agreement for the 2 sites ranged from 15 mm Hg (mean arterial pressure) to 18.4 mm Hg (systolic pressure). Despite strict attention to correct cuff size and placement of the upper arm or forearm at heart level, measurements of blood pressure obtained noninvasively in the arm and forearm of seated patients in stable condition are not interchangeable.

  20. Challenges in standardization of blood pressure measurement at the population level.

    Science.gov (United States)

    Tolonen, Hanna; Koponen, Päivikki; Naska, Androniki; Männistö, Satu; Broda, Grazyna; Palosaari, Tarja; Kuulasmaa, Kari

    2015-04-10

    Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed. The European Health Examination Survey (EHES) Pilot project was conducted in 2009-2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization. The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement. It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.