WorldWideScience

Sample records for measurements systems evaluation

  1. Measurement and evaluation systems for NPP commissioning

    International Nuclear Information System (INIS)

    Elko, Marek

    2006-01-01

    Standard core monitoring and information systems are designed with an emphasis on normal operation of nuclear power plant. Their purpose is to provide necessary support for reactor operators and other operating personnel during the fuel cycle. After each fuel reloading, and to the larger extent during the plant commissioning, a variety of start-up tests need to be carried out and evaluated. Sampling periods, accuracy and communication delays of standard systems are not always suitable for test performance and evaluation. For technical and safety reasons, the access to standard monitoring and information systems is very limited. Non-Standard Measurement and Evaluation Systems are highly specialized devices designed with an emphasis on start-up tests performance and evaluation. They are capable of high frequency sampling, processing and communication of hundreds of technological signals with required accuracy and low communication delay. All technological signals needed for the test performance and evaluation are collected from various systems, concentrated in one system and fully accessible to a test leader, a reactor physicist or other users. In addition, Non-Standard Measurement and Evaluation Systems can perform other tasks like data storing and presentation, data distribution to other systems or external computers via network, reactivity calculations, etc. Structure of such systems can vary, but generally it is a mixture of two basic concepts: a mobile system and a stationary system. A basic description of hardware structure and software equipment of Non-Standard Measurement and Evaluation Systems is given in the paper (Authors)

  2. Evaluation of the MADAM waste measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Foster, L.A.; Wachter, J.R.; Hagan, R.C.

    1995-03-01

    The Multiple Assay Dual Analysis Measurement (MADAM) system is a combined low-level and transuranic waste assay system. The system integrates commercially available Segmented Gamma Scanner (SGS) capability with a multienergy x-ray and gamma-ray analysis to measure these two waste forms. In addition, the system incorporates a small neutron slab detector to satisfy safeguards concerns and the capability for automated high-resolution gamma-ray analysis for isotope identification. Since delivery of the system to this facility, an evaluation of the waste measurement characteristics of the system has been conducted. A set of specially constructed NIST-traceable standards was fabricated for calibration and evaluation of the low-level waste (LLW) measurement system. The measurement characteristics of the LLW assay system were determined during the evaluation, including detection limits for all isotopes of interest, matrix attenuation effects, and detector response as a function of source position. Based on these studies, several modifications to the existing analysis algorithms have been performed, new correction factors for matrix attenuation have been devised, and measurement error estimates have been calculated and incorporated into the software.

  3. Evaluation of the MADAM waste measurement system

    International Nuclear Information System (INIS)

    Foster, L.A.; Wachter, J.R.; Hagan, R.C.

    1995-01-01

    The Multiple Assay Dual Analysis Measurement (MADAM) system is a combined low-level and transuranic waste assay system. The system integrates commercially available Segmented Gamma Scanner (SGS) capability with a multienergy x-ray and gamma-ray analysis to measure these two waste forms. In addition, the system incorporates a small neutron slab detector to satisfy safeguards concerns and the capability for automated high-resolution gamma-ray analysis for isotope identification. Since delivery of the system to this facility, an evaluation of the waste measurement characteristics of the system has been conducted. A set of specially constructed NIST-traceable standards was fabricated for calibration and evaluation of the low-level waste (LLW) measurement system. The measurement characteristics of the LLW assay system were determined during the evaluation, including detection limits for all isotopes of interest, matrix attenuation effects, and detector response as a function of source position. Based on these studies, several modifications to the existing analysis algorithms have been performed, new correction factors for matrix attenuation have been devised, and measurement error estimates have been calculated and incorporated into the software

  4. An evaluation of professional quality measurement systems for the ...

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology ... An evaluation of professional quality measurement systems for the automotive industry ... The ultimate goal of this study is to get comparable quantitative information about ...

  5. Improving Teacher Evaluation Systems: Making the Most of Multiple Measures

    Science.gov (United States)

    Grissom, Jason A., Ed.; Youngs, Peter, Ed.

    2015-01-01

    This is the first book to gather and address what we have learned about the impacts and challenges of data-intensive teacher evaluation systems--a defining characteristic of the current education policy landscape. Expert researchers and practitioners speak to what we know (and what remains to be known) about evaluation measures themselves, the…

  6. Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS)

    Energy Technology Data Exchange (ETDEWEB)

    Bland, Geoffrey [NASA Goddard Space Flight Center (GSFC), Greenbelt, MD (United States)

    2016-06-30

    The use of small unmanned aircraft systems (sUAS) with miniature sensor systems for atmospheric research is an important capability to develop. The Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS) project, lead by Dr. Gijs de Boer of the Cooperative Institute for Research in Environmental Sciences (CIRES- a partnership of NOAA and CU-Boulder), is a significant milestone in realizing this new potential. This project has clearly demonstrated that the concept of sUAS utilization is valid, and miniature instrumentation can be used to further our understanding of the atmospheric boundary layer in the arctic.

  7. Evaluation of microcomputer assisted system for nuclear emulsion measurement, 2

    International Nuclear Information System (INIS)

    Sato, Yoshihiro; Tezuka, Ikuo; Izawa, Kazuo.

    1983-01-01

    In the reaction of hardrons of several hundreds GeV/c, charm particles with from 10 -12 to 10 -13 second lifetime and beauty particles of shorter lifetime are generated. For directly observing these particles, the experiment using a system which combines nuclear emulsion and an electronic counter is carried out. The authors have engaged in the development of a nuclear emulsion analyzing system since several years ago, and recently developed a program for that system, and made measurement using the program, as one of the works to participate in the NA-19 hybrid experiment of this type, which is a high energy experiment implemented with the CERN accelerator using 350 GeV/c π - beam. In this report, first the outline of NA-19 experiment, next the corresponding of counter coordinates to nuclear emulsions, and the search for candidate events, in which two or more muons exist, that passed iron and tungsten dampers, are described. Further, the measuring programs XPRED 5 and CRS 34 and the relationship between these programs and measuring procedure and the evaluation for them are described at the end. The present program allows the measurement of generated secondary particles without any trouble up to the distance of 5 mm downstream from the collision point. It was also found that the program was applicable to the measurement of the decay phenomena and kink of the particles expected in the measurement of short-life particles. The system capability of estimating the position of target particles within 10 μm greatly contributes to this. (Wakatsuki, Y.)

  8. Temperature measurement and control system for transtibial prostheses: Functional evaluation.

    Science.gov (United States)

    Ghoseiri, Kamiar; Zheng, Yong Ping; Leung, Aaron K L; Rahgozar, Mehdi; Aminian, Gholamreza; Lee, Tat Hing; Safari, Mohammad Reza

    2018-01-01

    The accumulation of heat inside the prosthetic socket increases skin temperature and fosters perspiration, which consequently leads to high tissue stress, friction blister, discomfort, unpleasant odor, and decreased prosthesis suspension and use. In the present study, the prototype of a temperature measurement and control (TM&C) system was designed, fabricated, and functionally evaluated in a phantom model of the transtibial prosthetic socket. The TM&C system was comprised of 12 thermistors divided equally into two groups that arranged internal and external to a prosthetic silicone liner. Its control system was programmed to select the required heating or cooling function of a thermal pump to provide thermal equilibrium based on the amount of temperature difference from a defined set temperature, or the amount of difference between the mean temperature recorded by inside and outside thermistors. A thin layer of aluminum was used for thermal conduction between the thermal pump and different sites around the silicone liner. The results showed functionality of the TM&C system for thermoregulation inside the prosthetic socket. However, enhancing the structure of this TM&C system, increasing its thermal power, and decreasing its weight and cost are main priorities before further development.

  9. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.

    Science.gov (United States)

    Freckmann, Guido; Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Link, Manuela; Haug, Cornelia

    2014-02-01

    Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.

  10. Evaluation and proposal of improvement for the measurement system in ATLAS

    International Nuclear Information System (INIS)

    Cho, Dong Woo; Kim, Jong Rok; Park, Jun Kwon

    2007-03-01

    The project independently evaluated the validities and reliability of measurement system in ATLAS, then proposed plans to improve the measurement system from evaluated results. For this objectives, we evaluated the design, technical backgrounds, verifying data of measurement system in ATLAS. From this evaluation, we proposed plans for improvement on parts which need improvement

  11. A measuring instrument for evaluation of quality systems.

    NARCIS (Netherlands)

    Wagner, C.; Bakker, D.H. de; Groenewegen, P.P.

    1999-01-01

    Objective: To develop an instrument for provider organizations, consumers, purchasers, and policy makers to measure and compare the development of quality systems in provider organizations. Design: Cross-sectional study of provider organizations using a structured questionnaire to survey managers.

  12. Measurement evaluation

    CERN Document Server

    Boros, A

    1990-01-01

    The information obtained about a measured object is called ``crude'' measurement information and must be related to the conditions under which the measurement took place. Using ``crude'' measurement information as a starting point, evaluation produces physically correctly interpreted data with their estimated (or corrected) error. Although a number of works deal with the evaluation of measurements, they either appeared a long time ago or serve essentially different aims. This book gives a comprehensive and current overview on the basic principles, aids, devices, and methods in the eval

  13. Maximum respiratory pressure measuring system : calibration and evaluation of uncertainty

    NARCIS (Netherlands)

    Ferreira, J.L.; Pereira, N.C.; Oliveira Júnior, M.; Vasconcelos, F.H.; Parreira, V.F.; Tierra-Criollo, C.J.

    2010-01-01

    The objective of this paper is to present a methodology for the evaluation of uncertainties in the measurements results obtained during the calibration of a digital manovacuometer prototype (DM) with a load cell sensor pressure device incorporated. Calibration curves were obtained for both pressure

  14. Measurement and protocol for evaluating video and still stabilization systems

    Science.gov (United States)

    Cormier, Etienne; Cao, Frédéric; Guichard, Frédéric; Viard, Clément

    2013-01-01

    This article presents a system and a protocol to characterize image stabilization systems both for still images and videos. It uses a six axes platform, three being used for camera rotation and three for camera positioning. The platform is programmable and can reproduce complex motions that have been typically recorded by a gyroscope mounted on different types of cameras in different use cases. The measurement uses a single chart for still image and videos, the texture dead leaves chart. Although the proposed implementation of the protocol uses a motion platform, the measurement itself does not rely on any specific hardware. For still images, a modulation transfer function is measured in different directions and is weighted by a contrast sensitivity function (simulating the human visual system accuracy) to obtain an acutance. The sharpness improvement due to the image stabilization system is a good measurement of performance as recommended by a CIPA standard draft. For video, four markers on the chart are detected with sub-pixel accuracy to determine a homographic deformation between the current frame and a reference position. This model describes well the apparent global motion as translations, but also rotations along the optical axis and distortion due to the electronic rolling shutter equipping most CMOS sensors. The protocol is applied to all types of cameras such as DSC, DSLR and smartphones.

  15. Evaluation of an attributive measurement system in the automotive industry

    Science.gov (United States)

    Simion, C.

    2016-08-01

    Measurement System Analysis (MSA) is a critical component for any quality improvement process. MSA is defined as an experimental and mathematical method of determining how much the variation within the measurement process contributes to overall process variability and it falls into two categories: attribute and variable. Most problematic measurement system issues come from measuring attribute data, which are usually the result of human judgment (visual inspection). Because attributive measurement systems are often used in some manufacturing processes, their assessment is important to obtain the confidence in the inspection process, to see where are the problems in order to eliminate them and to guide the process improvement. It was the aim of this paper to address such a issue presenting a case study made in a local company from the Sibiu region supplying products for the automotive industry, specifically the bag (a technical textile component, i.e. the fabric) for the airbag module. Because defects are inherent in every manufacturing process and in the field of airbag systems a minor defect can influence their performance and lives depend on the safety feature, there is a stringent visual inspection required on the defects of the bag material. The purpose of this attribute MSA was: to determine if all inspectors use the same criteria to determine “pass” from “fail” product (i.e. the fabric); to assess company inspection standards against customer's requirements; to determine how well inspectors are conforming to themselves; to identify how inspectors are conforming to a “known master,” which includes: how often operators ship defective product, how often operators dispose of acceptable product; to discover areas where training is required, procedures must be developed and standards are not available. The results were analyzed using MINITAB software with its module called Attribute Agreement Analysis. The conclusion was that the inspection process must

  16. Thoracic ROM measurement system with visual bio-feedback: system design and biofeedback evaluation.

    Science.gov (United States)

    Ando, Takeshi; Kawamura, Kazuya; Fujitani, Junko; Koike, Tomokazu; Fujimoto, Masashi; Fujie, Masakatsu G

    2011-01-01

    Patients with diseases such as chronic obstructive pulmonary disease (COPD) need to improve their thorax mobility. Thoracic ROM is one of the simplest and most useful indexes to evaluate the respiratory function. In this paper, we have proposed the prototype of a simple thoracic ROM measurement system with real-time visual bio-feedback in the chest expansion test. In this system, the thoracic ROM is measured using a wire-type linear encoder whose wire is wrapped around the thorax. In this paper, firstly, the repeatability and reliability of measured thoracic ROM was confirmed as a first report of the developed prototype. Secondly, we analyzed the effect of the bio-feedback system on the respiratory function. The result of the experiment showed that it was easier to maintain a large and stable thoracic ROM during deep breathing by using the real-time visual biofeedback system of the thoracic ROM.

  17. Midterm Stability Evaluation of Wide-area Power System by using Synchronized Phasor Measurements

    Science.gov (United States)

    Ota, Yutaka; Ukai, Hiroyuki; Nakamura, Koichi; Fujita, Hideki

    In recent years, the PMU (Phasor Measurement Unit) receives a great deal of attention as a synchronized measurement system of power systems. Synchronized phasor angles obtained by the PMU provide the effective information for evaluating the stability of a bulk power system. The aspect of instability phenomena during midterm tends to be more complicated, and the stability analysis using the synchronized phasor measurements is significant in order to keep a complicated power system stable. This paper proposes a midterm stability evaluation method of the wide-area power system by using the synchronized phasor measurements. By clustering and aggregating the power system to some coherent groups, the step-out is effectively predicted on the basis of the two-machine equivalent power system model. The midterm stability of a longitudinal power system model of Japanese 60Hz systems constructed by the PSA, which is a hybrid-type power system simulator, is practically evaluated using the proposed method.

  18. Usage of performance measurement and evaluation systems : the impact of evaluator characteristics

    OpenAIRE

    Gelderman, Maarten

    1998-01-01

    This paper discusses the relation between characteristics of the evaluating manager and the way performance measurement and evaluation information is used. First a discussion is provided about the dependent variable. It is recognized that categorization into archetypes (e.g., evaluative styles) is unsatisfactory. Instead the information content/emphasis dimensions financial-non- financial, quantitative-qualitative, process-outcome, past-future and external-internal, along with the dimension f...

  19. Test, measurement and evaluation with the mine boot test and evaluation system

    CSIR Research Space (South Africa)

    Ramaloko, PM

    2014-09-01

    Full Text Available Protective footwear that mitigates the shock transferred to the victim’s leg during an antipersonnel landmine blast need to be evaluated to verify their protection levels. The Mine Boot Test and Evaluation System which include a surrogate lower leg...

  20. Radionuclide measuring systems and improved methods of evaluation for the measurement of wear in stationary and mobile systems

    International Nuclear Information System (INIS)

    Lausch, W.

    1976-01-01

    A newly developped flow through measuring unit makes it possible to perform continuous wear measurements on stationary and mobile systems. It was specifically designed for measurements on engine components of passenger cars. For tests of long duration an oil sampling technique was developed. Fully automated measurements are achieved with a sampling device suitable for both stationary and mobile systems. For systems with oil consumption a mathematical model provides for the necessary connection of the loss of wear particles through oil consumption. In certain cases an empirical graphical method can achieve nearly the same results. (orig.) [de

  1. Biomagnetic Measurement System on Mice-Evaluation of System Performance by MCG and Application to MEG

    International Nuclear Information System (INIS)

    Nakamura, T; Shirai, K; Ono, Y; Kasai, N; Odawara, A; Ishiyama, A

    2006-01-01

    We developed a biomagnetic measurement system on mice. Our initial model of the system has the magnetic field sensitivity of 1.3 pT/Hz 1/2 in the white-noise region (10 Hz-10 kHz). And using the system, we succeeded to obtain magnetically the heart activity on mice. However, in its application to measure the brain activity on mice, it was necessary to improve the magnetic field sensitivity of the system. Therefore, we changed the material of the window cap, which holds a sapphire glass window on the dewar tail, to ceramic. The system noise was decreased and the magnetic field sensitivity of the system was improved to 0.75 pT/Hz 1/2 in the white-noise region. For an initial measurement of the brain activity, we also developed a whisker stimulation system using a piezoelectric element to evoke somatosensory responses

  2. Evaluation of the Space and Naval Warfare Systems Command (SPAWAR) Cost and Performance Measurement

    OpenAIRE

    Flavell, Drew G.; Dorwin, Timothy E.

    1999-01-01

    Approved for public release; distribution is unlimited. This thesis examines the Cost and Performance Measurements within four Program Directorates at the Space and Naval Warfare Systems Command (SPAWAR). SPAWAR is the Navy's full-spectrum research, development, test and evaluation, engineering and fleet support center for Command, Control and Communications Systems, Ocean Surveillance Systems and the integration of those systems that overarch multiplatforms. In the era of lean military bu...

  3. Multiple performance measures are needed to evaluate triage systems in the emergency department.

    Science.gov (United States)

    Zachariasse, Joany M; Nieboer, Daan; Oostenbrink, Rianne; Moll, Henriëtte A; Steyerberg, Ewout W

    2018-02-01

    Emergency department triage systems can be considered prediction rules with an ordinal outcome, where different directions of misclassification have different clinical consequences. We evaluated strategies to compare the performance of triage systems and aimed to propose a set of performance measures that should be used in future studies. We identified performance measures based on literature review and expert knowledge. Their properties are illustrated in a case study evaluating two triage modifications in a cohort of 14,485 pediatric emergency department visits. Strengths and weaknesses of the performance measures were systematically appraised. Commonly reported performance measures are measures of statistical association (34/60 studies) and diagnostic accuracy (17/60 studies). The case study illustrates that none of the performance measures fulfills all criteria for triage evaluation. Decision curves are the performance measures with the most attractive features but require dichotomization. In addition, paired diagnostic accuracy measures can be recommended for dichotomized analysis, and the triage-weighted kappa and Nagelkerke's R 2 for ordinal analyses. Other performance measures provide limited additional information. When comparing modifications of triage systems, decision curves and diagnostic accuracy measures should be used in a dichotomized analysis, and the triage-weighted kappa and Nagelkerke's R 2 in an ordinal approach. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Measurement-Based Evaluation of Installed Filtration System Performance in Single-Family Homes

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wanyu Rengie; Singer, Brett C.

    2014-04-03

    This guide discusses important study design issues to consider when conducting an on-site evaluation of filtration system performance. The two most important dichotomies to consider in developing a study protocol are (1) whether systems are being evaluated in occupied or unoccupied homes and (2) whether different systems are being compared in the same homes or if the comparison is between systems installed in different homes. This document provides perspective and recommendations about a suite of implementation issues including the choice of particle measurement devices, selection of sampling locations, ways to control and/or monitor factors and processes that can impact particle concentrations, and data analysis approaches.

  5. Evaluation of Routine Atmospheric Sounding Measurements Using Unmanned Systems (ERASMUS) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    de Boer, Gijs [Univ. of Colorado, Boulder, CO (United States). Cooperative Inst. for Research in Environmental Sciences (CIRES); Lawrence, Dale [Univ. of Colorado, Boulder, CO (United States); Palo, Scott [Univ. of Colorado, Boulder, CO (United States); Argrow, Brian [Univ. of Colorado, Boulder, CO (United States); LoDolce, Gabriel [Univ. of Colorado, Boulder, CO (United States); Curry, Nathan [Univ. of Colorado, Boulder, CO (United States); Weibel, Douglas [Univ. of Colorado, Boulder, CO (United States); Finnamore, W [Univ. of Colorado, Boulder, CO (United States); D' Amore, P [Univ. of Colorado, Boulder, CO (United States); Borenstein, Steven [Univ. of Colorado, Boulder, CO (United States); Nichols, Tevis [Univ. of Colorado, Boulder, CO (United States); Elston, Jack [Blackswift Technologies, Boulder, CO (United States); Ivey, Mark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bendure, Al [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schmid, Beat [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Long, Chuck [National Oceanic and Atmospheric Administration (NOAA), Boulder, CO (United States). Earth System Research Lab.; Telg, Hagen [Univ. of Colorado, Boulder, CO (United States). Cooperative Inst. for Research in Environmental Sciences (CIRES); Gao, Rushan [National Oceanic and Atmospheric Administration (NOAA), Boulder, CO (United States). Earth System Research Lab.; Hock, T [National Center for Atmospheric Research, Boulder, CO (United States); Bland, Geoff [National Aeronautics and Space Administration (NASA), Washington, DC (United States)

    2017-03-01

    The Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS) campaign was proposed with two central goals; to obtain scientifically relevant measurements of quantities related to clouds, aerosols, and radiation, including profiles of temperature, humidity, and aerosol particles, the structure of the arctic atmosphere during transitions between clear and cloudy states, measurements that would allow us to evaluate the performance of retrievals from U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility remote sensors in the Arctic atmosphere, and information on the spatial variability of heat and moisture fluxes from the arctic surface; and to demonstrate unmanned aerial system (UAS) capabilities in obtaining measurements relevant to the ARM and ASR programs, particularly for improving our understanding of Arctic clouds and aerosols.

  6. Statistical evaluation of failures and repairs of the V-1 measuring and control system

    International Nuclear Information System (INIS)

    Laurinec, R.; Korec, J.; Mitosinka, J.; Zarnovican, V.

    1984-01-01

    A failure record card system was introduced for evaluating the reliability of the measurement and control equipment of the V-1 nuclear power plant. The SPU-800 microcomputer system is used for recording data on magnetic tape and their transmission to the central data processing department. The data are used for evaluating the reliability of components and circuits and a selection is made of the most failure-prone components, and the causes of failures are evaluated as are failure identification, repair and causes of outages. The system provides monthly, annual and total assessment data since the system was commissioned. The results of the statistical evaluation of failures are used for planning preventive maintenance and for determining optimal repair intervals. (E.S.)

  7. Direct Heat-Flux Measurement System (MDF) for Solar central Receiver Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Ballestrin, J.

    2001-07-01

    A direct flux measurement system, MDF, has been designed, constructed and mounted on top of the SSPS-CRS tower at the Plataforma Solar de Almeria (PSA) in addition to an indirect flux measurement system based on a CCD camera. It's one of the main future objectives to compare systematically both measurements of the concentrated solar power, increasing in this way the confidence in the estimate of this quantity. Today everything is prepared to perform the direct flux measurement on the aperture of solar receivers: calorimeter array, data acquisition system and software. the geometry of the receiver determines the operation and analysis procedures to obtain the indecent power onto the defined area. The study of previous experiences with direct flux measurement systems ha been useful to define a new simpler and more accurate system. A description of each component of the MDF system is included, focusing on the heat-flux sensors or calorimeters, which enables these measurements to be done in a few seconds without water-cooling. The incident solar power and the spatial flux distribution on the aperture of the volumetric receiver Hitrec II are supplied by the above-mentioned MDF system. The first results obtained during the evaluation of this solar receiver are presented including a sunrise-sunset test. All these measurements have been concentrated in one coefficient that describes the global behavior of the Solar Power Plant. (Author) 18 refs.

  8. Measuring, processing and evaluation of dynamic signal components of diagnostic systems and instrumentation and control systems at the Temelin NPP

    International Nuclear Information System (INIS)

    Stulik, P.; Sipek, B.

    2005-10-01

    The quality of the RVMS measuring chains was examined during an outage of the Temelin-1 reactor unit. This consisted of a defined measurement of the measuring chain output of the ionization chambers of the power zone and thermocouples by the RVMS system, processing of the time series obtained, and evaluation of the spectral parameters within the given frequency band. The results of evaluation were classified for the transfer function values along with their differences and for the phase shift values. The dynamic components of the resistance thermometers on the primary loops of the Temelin-1 and 2 reactor units were measured and the measurements were evaluated. The results in the frequency region, in the form of spectral characteristics for both the hot and cold legs, indicate that the non-invasive determination of the dynamics of the resistance thermometer measuring chains can serve as a promising basic tool for the diagnosis and life monitoring of this important in-service measurement

  9. Design and performance evaluation of a broadband three dimensional acoustic intensity measuring system.

    Science.gov (United States)

    Miah, Khalid H; Hixon, Elmer L

    2010-04-01

    A seven-microphone three dimensional (3D) intensity measuring system has been developed and evaluated for performance for a broad frequency band (200 Hz-6.5 kHz). Six microphones are arranged in a concentric array with one microphone at the center of the probe. The screw adjustable center microphone is the probe reference microphone, and is used for calibrations of the other microphones in the probe. This probe addresses limitations of the traditional two-microphone system in measuring acoustical properties in a 3D space from the one dimensional measurements. This probe also eliminates the need of spacers used in the existing 3D probes for broadband measurements. Diffraction and reflection effects on calibrations due to presence of the microphones and the probe supporting structure are negligible. This seven-microphone probe provided better results in the intensity measurements for the wide frequency band than that of a similar four-microphone array probe.

  10. DEVELOPMENT AND EVALUATION OF SIMPLE MEASUREMENT SYSTEM USING THE OBLIQUE PHOTO AND DEM

    Directory of Open Access Journals (Sweden)

    H. Nonaka

    2016-06-01

    Full Text Available When a disaster occurs, we must grasp and evaluate its damage as soon as possible. Then we try to estimate them from some kind of photographs, such as surveillance camera imagery, satellite imagery, photographs taken from a helicopter and so on. Especially in initial stage, estimation of decent damage situation for a short time is more important than investigation of damage situation for a long time. One of the source of damage situation is the image taken by surveillance camera, satellite sensor and helicopter. If we can measure any targets in these imagery, we can estimate a length of a lava flow, a reach of a cinder and a sediment volume in volcanic eruption or landslide. Therefore in order to measure various information for a short time, we developed a simplified measurement system which uses these photographs. This system requires DEM in addition to photographs, but it is possible to use previously acquired DEM. To measure an object, we require only two steps. One is the determination of the position and the posture in which the photograph is shot. We determine these parameters using DEM. The other step is the measurement of an object in photograph. In this paper, we describe this system and show the experimental results to evaluate this system. In this experiment we measured the top of Mt. Usu by using two measurement method of this system. Then we can measure it about one hour and the difference between the measurement results and the airborne LiDAR data are less than 10 meter.

  11. Evaluation of screen-film system quality: physical principles and measurement techniques

    International Nuclear Information System (INIS)

    Borasi, G.; Berardi, P.; Ferretti, P.P.; Piccagli, V.

    1990-01-01

    Comparative evaluation of radiographic filmscreen systems presents several problems from both the theoretical and the experimental point of view. From the theoretical point of view the main difficulties are related to the choice of the parameters best suited to express the 'overall quality' of a system. From the practical point of view the main problem is that to measure some basic quantities (resolution and noise) sophisticated and expensive instruments are required. This paper deals with both these problems. To express image quality we have assumed the signal-to-noise power ration: this index depends in a explicit way on contrast, resolution and noise of the system. The dependence on sensitivity is implicit and was derived using literature data. From a knowledge of the dependence of image quality on sensitivity it is possible to develop an 'overall quality' index which is considered to express the 'technological level' of the systems. In this work some basic phisical quantities (characteristic curve, sensitivity) were evaluated using standard instruments. To measure spatial resolution and noise an inexpensive, PC-based, TV-digitizer system was developed. As an example, both image and overall quality indices were evaluated on three mammographic systems which are typical of the three different 'phases' of the development of this technique

  12. Local difference measures between complex networks for dynamical system model evaluation.

    Science.gov (United States)

    Lange, Stefan; Donges, Jonathan F; Volkholz, Jan; Kurths, Jürgen

    2015-01-01

    A faithful modeling of real-world dynamical systems necessitates model evaluation. A recent promising methodological approach to this problem has been based on complex networks, which in turn have proven useful for the characterization of dynamical systems. In this context, we introduce three local network difference measures and demonstrate their capabilities in the field of climate modeling, where these measures facilitate a spatially explicit model evaluation.Building on a recent study by Feldhoff et al. [8] we comparatively analyze statistical and dynamical regional climate simulations of the South American monsoon system [corrected]. types of climate networks representing different aspects of rainfall dynamics are constructed from the modeled precipitation space-time series. Specifically, we define simple graphs based on positive as well as negative rank correlations between rainfall anomaly time series at different locations, and such based on spatial synchronizations of extreme rain events. An evaluation against respective networks built from daily satellite data provided by the Tropical Rainfall Measuring Mission 3B42 V7 reveals far greater differences in model performance between network types for a fixed but arbitrary climate model than between climate models for a fixed but arbitrary network type. We identify two sources of uncertainty in this respect. Firstly, climate variability limits fidelity, particularly in the case of the extreme event network; and secondly, larger geographical link lengths render link misplacements more likely, most notably in the case of the anticorrelation network; both contributions are quantified using suitable ensembles of surrogate networks. Our model evaluation approach is applicable to any multidimensional dynamical system and especially our simple graph difference measures are highly versatile as the graphs to be compared may be constructed in whatever way required. Generalizations to directed as well as edge- and node

  13. A safety-critical decision support system evaluation using situation awareness and workload measures

    International Nuclear Information System (INIS)

    Naderpour, Mohsen; Lu, Jie; Zhang, Guangquan

    2016-01-01

    To ensure the safety of operations in safety-critical systems, it is necessary to maintain operators' situation awareness (SA) at a high level. A situation awareness support system (SASS) has therefore been developed to handle uncertain situations [1]. This paper aims to systematically evaluate the enhancement of SA in SASS by applying a multi-perspective approach. The approach consists of two SA metrics, SAGAT and SART, and one workload metric, NASA-TLX. The first two metrics are used for the direct objective and subjective measurement of SA, while the third is used to estimate operator workload. The approach is applied in a safety-critical environment called residue treater, located at a chemical plant in which a poor human-system interface reduced the operator's SA and caused one of the worst accidents in US history. A counterbalanced within-subjects experiment is performed using a virtual environment interface with and without the support of SASS. The results indicate that SASS improves operators' SA, and specifically has benefits for SA levels 2 and 3. In addition, it is concluded that SASS reduces operator workload, although further investigations in different environments with a larger number of participants have been suggested. - Highlights: • The suitability of a cognitive decision support system is investigated. • An evaluation approach considering situation awareness and workload measures is proposed. • A computerized system based on the proposed approach is implemented. • The implemented system is used in a safety-critical environment.

  14. Symmetry evaluation for an interferometric fiber optic gyro coil utilizing a bidirectional distributed polarization measurement system.

    Science.gov (United States)

    Peng, Feng; Li, Chuang; Yang, Jun; Hou, Chengcheng; Zhang, Haoliang; Yu, Zhangjun; Yuan, Yonggui; Li, Hanyang; Yuan, Libo

    2017-07-10

    We propose a dual-channel measurement system for evaluating the optical path symmetry of an interferometric fiber optic gyro (IFOG) coil. Utilizing a bidirectional distributed polarization measurement system, the forward and backward transmission performances of an IFOG coil are characterized simultaneously by just a one-time measurement. The simple but practical configuration is composed of a bidirectional Mach-Zehnder interferometer and multichannel transmission devices connected to the IFOG coil under test. The static and dynamic temperature results of the IFOG coil reveal that its polarization-related symmetric properties can be effectively obtained with high accuracy. The optical path symmetry investigation is highly beneficial in monitoring and improving the winding technology of an IFOG coil and reducing the nonreciprocal effect of an IFOG.

  15. Nondestructive Evaluation of Railway Bridge by System Identification Using Field Vibration Measurement

    International Nuclear Information System (INIS)

    Ho, Duc Duy; Hong, Dong Soo; Kim, Jeong Tae

    2010-01-01

    This paper presents a nondestructive evaluation approach for system identification (SID) of real railway bridges using field vibration test results. First, a multi-phase SID scheme designed on the basis of eigenvalue sensitivity concept is presented. Next, the proposed multi-phase approach is evaluated from field vibration tests on a real railway bridge (Wondongcheon bridge) located in Yangsan, Korea. On the steel girder bridge, a few natural frequencies and mode shapes are experimentally measured under the ambient vibration condition. The corresponding modal parameters are numerically calculated from a three-dimensional finite element (FE) model established for the target bridge. Eigenvalue sensitivities are analyzed for potential model-updating parameters of the FE model. Then, structural subsystems are identified phase-by-phase using the proposed model-updating procedure. Based on model-updating results, a baseline model and a nondestructive evaluation of test bridge are identified

  16. Development of Radioactive Inventory Evaluation System using 3D Shape and Multiple Radiation Measurement

    International Nuclear Information System (INIS)

    Lee, Sang Chul; Kim, Won Seok; Han, Byong Su; Moon, Joo Hyun

    2013-01-01

    The increase of the operating NPPs and the superannuation of the equipment in NPPs cause a large amount of the metal radioactive waste. Presently the metal radioactive wastes are stored in the temporary storage facility in NPPs because of the delay of the construction of the final disposal facility. The radioactive level of general metal radioactive wastes is low, and the radioactive level can be lowered by the simple decontamination process. If the radioactive wastes are disposed as the industry waste, the disposal cost is diminished largely. For the disposal of the radioactive wastes as the industrial wastes, the radioactive level of the target wastes are evaluated. It is difficult to know the position of the source term for most of the metal radioactive and the source term is distributed non-homogeneously. And the self-shielding effect of the metal material makes the evaluation more difficult. In this study, the radioactive inventory evaluation system for the metal radioactive waste is developed. For the correction of the uncertainty of the position and the non-homogeneity of the source term, the 3D shape and multiple radiation measurement are used. The existing gamma-ray measurement system for the metal radioactive waste cannot reflect the position and the distribution of the source term and the effect of self-shielding. This evaluation system suggested in this system can calculate the reasonable value regarding to the position and the distribution of the source term and the effect of self-shielding. By the calculation of the partial inventory of the target metal waste, the advantage in the application of the clearance criteria can be obtained

  17. Temperature measurement and control system for transtibial prostheses: Single subject clinical evaluation.

    Science.gov (United States)

    Ghoseiri, Kamiar; Zheng, Yong Ping; Leung, Aaron K L; Rahgozar, Mehdi; Aminian, Gholamreza; Masoumi, Mehdi; Safari, Mohammad Reza

    2018-01-01

    The snug fit of a prosthetic socket over the residual limb can disturb thermal balance and put skin integrity in jeopardy by providing an unpleasant and infectious environment. The prototype of a temperature measurement and control (TM&C) system was previously introduced to resolve thermal problems related to prostheses. This study evaluates its clinical application in a setting with reversal, single subject design. The TM&C system was installed on a fabricated prosthetic socket of a man with unilateral transtibial amputation. Skin temperature of the residual limb without prosthesis at baseline and with prosthesis during rest and walking was evaluated. The thermal sense and thermal comfort of the participant were also evaluated. The results showed different skin temperature around the residual limb with a temperature decrease tendency from proximal to distal. The TM&C system decreased skin temperature rise after prosthesis wearing. The same situation occurred during walking, but the thermal power of the TM&C system was insufficient to overcome heat build-up in some regions of the residual limb. The participant reported no significant change of thermal sense and thermal comfort. Further investigations are warranted to examine thermography pattern of the residual limb, thermal sense, and thermal comfort in people with amputation.

  18. Application of a system for measuring foot plantar pressure for evaluation of human mobility

    Science.gov (United States)

    Klimiec, Ewa; Jasiewicz, Barbara; Zaraska, Krzysztof; Piekarski, Jacek; Guzdek, Piotr; Kołaszczyński, Grzegorz

    2016-11-01

    The paper presents evaluation of human mobility by gait analysis, carried out in natural conditions (outside laboratory). Foot plantar pressure is measured using a shoe insole with 8 sensors placed in different anatomical zones of the foot, and placed inside a sports footwear. Polarized PVDF foil is used as a sensor material. A wireless transmission system is used to transmit voltage values to the computer. Due to linear relationship between force and transducer voltage, energy released during walking in arbitrary units can be calculated as integral of the square of transducer voltage over time. Gait measurements have been done over the next few days on healthy person during normal walking and slow walking. Performed measurements allow determination of walking speed (number of steps per second), gait rhythm and manner of walking (applying force to inside versus outside part of the sole). It is found that switching from normal to slow walk increases gait energy by 25% while the pressure distribution across the anatomical regions of the foot remains unchanged. The results will be used for developing a programme for evaluation of patients with cardiac failure and future integration of actimetry with pulse and spirometry measurements.

  19. Color structured light system of chest wall motion measurement for respiratory volume evaluation

    Science.gov (United States)

    Chen, Huijun; Cheng, Yuan; Liu, Dongdong; Zhang, Xiaodong; Zhang, Jue; Que, Chengli; Wang, Guangfa; Fang, Jing

    2010-03-01

    We present a structured light system to dynamically measure human chest wall motion for respiratory volume estimation. Based on a projection of an encoded color pattern and a few active markers attached to the trunk, respiratory volumes are obtained by evaluating the 3-D topographic changes of the chest wall in an anatomically consistent measuring region during respiration. Three measuring setups are established: a single-sided illuminating-recording setup for standing posture, an inclined single-sided setup for supine posture, and a double-sided setup for standing posture. Results are compared with the pneumotachography and show good agreement in volume estimations [correlation coefficient: R>0.99 (Pvolume during the isovolume maneuver (standard deviationpulmonary functional differences between the diseased and the contralateral sides of the thorax, and subsequent improvement of this imbalance after drainage. These results demonstrate the proposed optical method is capable of not only whole respiratory volume evaluation with high accuracy, but also regional pulmonary function assessment in different chest wall behaviors, with the advantage of whole-field measurement.

  20. Application-Driven Reliability Measures and Evaluation Tool for Fault-Tolerant Real-Time Systems

    National Research Council Canada - National Science Library

    Krishna, C

    2001-01-01

    .... The measure combines graphic-theoretic concepts in evaluating the underlying reliability of the network and other means to evaluate the ability of the network to support interprocessor traffic...

  1. Measure Evaluation Dataverse

    Data.gov (United States)

    US Agency for International Development — The MEASURE Evaluation Dataverse is a collection of innovative evaluation data sets assembled in order to increase the evidence-base on program impact and evaluate...

  2. Evaluation and development of measurement components for a catalytic converter test system

    Energy Technology Data Exchange (ETDEWEB)

    Chan, A.K.

    1997-08-01

    The purpose of this research and development project was to evaluate and configure the components of a test system designed for the analysis of full-scale vehicle-aged automobile catalytic converters. The components tested included an exhaust gas analyzer for measuring hydrocarbon, CO, CO{sub 2} and O{sub 2} contents and a chemiluminescence detector (CLD) for measuring NO{sub x}, as well as thermocouples and pressure meters. A software package (TestPoint vers.2.Ob, Capital Equipment) was used to develop a computer-based data sampling and acquisition interface with the components and sensors connected to the test system. Tests of the Sun MGA-1200, a non-dispersive infrared (NDIR) analyzer, with CO, CO{sub 2} and various hydrocarbons (propane and octane) revealed sensitivity to large pressure changes (greater than 500 mbar). There was no significant cross-sensitivity between the gases except for the slight response of the hydrocarbon (HC) register to water vapor and CO. However, the low range of HC(5-30 vppm) expected in car exhaust after the converter means any cross-sensitivity could have an effect on the measurement, depending on measurement conditions. Tests of the EcoPhysics CLD 700 NO{sub x} meter also indicated sensitivity to pressure. An executable TestPoint run-time application was created to allow near real-time monitoring of the test system using a desktop computer. Nine channels of analog data are fed to a desktop computer via an A/D board and seven exhaust gas parameters through an RS-232C interface with the MGA-1200 23 refs, 32 figs, 10 tabs. Examination paper

  3. Configuring Balanced Scorecards for Measuring Health System Performance: Evidence from 5 Years' Evaluation in Afghanistan

    Science.gov (United States)

    Edward, Anbrasi; Kumar, Binay; Kakar, Faizullah; Salehi, Ahmad Shah; Burnham, Gilbert; Peters, David H.

    2011-01-01

    Background In 2004, Afghanistan pioneered a balanced scorecard (BSC) performance system to manage the delivery of primary health care services. This study examines the trends of 29 key performance indicators over a 5-year period between 2004 and 2008. Methods and Findings Independent evaluations of performance in six domains were conducted annually through 5,500 patient observations and exit interviews and 1,500 provider interviews in >600 facilities selected by stratified random sampling in each province. Generalized estimating equation (GEE) models were used to assess trends in BSC parameters. There was a progressive improvement in the national median scores scaled from 0–100 between 2004 and 2008 in all six domains: patient and community satisfaction of services (65.3–84.5, pscorecard reconfigurations are needed to integrate effectiveness and efficiency measures and accommodate changes in health systems policy and strategy architecture to ensure its continued relevance and effectiveness as a comprehensive health system performance measure. The process of BSC design and implementation can serve as a valuable prototype for health policy planners managing performance in similar health care contexts. Please see later in the article for the Editors' Summary PMID:21814499

  4. Evaluation of impedance on biological Tissues using automatic control measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Kil, Sang Hyeong; Shin, Dong Hoon; Lee, Seong Mo [Pusan National University, Yangsan (Korea, Republic of); Lee, Moo Seok; Kim, Sang Sik [Pusan National University, Busan (Korea, Republic of); Kim, Gun FDo; Lee, Jong Kyu [Pukyung National University, Busan (Korea, Republic of)

    2015-08-15

    Each biological tissue has endemic electrical characteristics owing to various differences such as those in cellular arrangement or organization form. The endemic electrical characteristics change when any biological change occurs. This work is a preliminary study surveying the changes in the electrical characteristics of biological tissue caused by radiation exposure. For protection against radiation hazards, therefore the electrical characteristics of living tissue were evaluated after development of the automatic control measurement system using LabVIEW. No alteration of biological tissues was observed before and after measurement of the electrical characteristics, and the biological tissues exhibited similar patterns. Through repeated measurements using the impedance/gain-phase analyzer, the coefficient of variation was determined as within 10%. The reproducibility impedance phase difference in electrical characteristics of the biological tissue did not change, and the tissue had resistance. The absolute value of impedance decreased constantly in proportion to the frequency. It has become possible to understand the electrical characteristics of biological tissues through the measurements made possible by the use of the developed.

  5. Evaluation of impedance on biological Tissues using automatic control measurement system

    International Nuclear Information System (INIS)

    Kil, Sang Hyeong; Shin, Dong Hoon; Lee, Seong Mo; Lee, Moo Seok; Kim, Sang Sik; Kim, Gun FDo; Lee, Jong Kyu

    2015-01-01

    Each biological tissue has endemic electrical characteristics owing to various differences such as those in cellular arrangement or organization form. The endemic electrical characteristics change when any biological change occurs. This work is a preliminary study surveying the changes in the electrical characteristics of biological tissue caused by radiation exposure. For protection against radiation hazards, therefore the electrical characteristics of living tissue were evaluated after development of the automatic control measurement system using LabVIEW. No alteration of biological tissues was observed before and after measurement of the electrical characteristics, and the biological tissues exhibited similar patterns. Through repeated measurements using the impedance/gain-phase analyzer, the coefficient of variation was determined as within 10%. The reproducibility impedance phase difference in electrical characteristics of the biological tissue did not change, and the tissue had resistance. The absolute value of impedance decreased constantly in proportion to the frequency. It has become possible to understand the electrical characteristics of biological tissues through the measurements made possible by the use of the developed.

  6. Data Glove System Embedded With Inertial Measurement Units for Hand Function Evaluation in Stroke Patients.

    Science.gov (United States)

    Lin, Bor-Shing; Hsiao, Pei-Chi; Yang, Shu-Yu; Su, Che-Shih; Lee, I-Jung

    2017-11-01

    This paper proposes a data glove system integrated with six-axis inertial measurement unit sensors for evaluating the hand function of patients who have suffered a stroke. The modular design of this data glove facilitates its use for stroke patients. The proposed system can use the hand's accelerations, angular velocities, and joint angles as calculated by a quaternion algorithm, to help physicians gain new insights into rehabilitation treatments. A clinical experiment was performed on 15 healthy subjects and 15 stroke patients whose Brunnstrom stages (BSs) ranged from 4 to 6. In this experiment, the participants were subjected to a grip task, thumb task, and card turning task to produce raw data and three features, namely, the average rotation speed, variation of movement completion time, and quality of movement; these features were extracted from the recorded data to form 2-D and 3-D scatter plots. These scatter plots can provide reference information and guidance to physicians who must determine the BSs of stroke patients. The proposed system demonstrated a hit rate of 70.22% on average. Therefore, this system can effectively reduce physicians' load and provide them with detailed information about hand function to help them adjust rehabilitation strategies for stroke patients.

  7. The development of human factors experimental evaluation technology - 3-dimensional measurement system for motion analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Soo; Pan, Young Hwan; Lee, Ahn Jae; Lee, Kyung Tae; Lim, Chi Hwan; Chang, Pil Sik; Lee, Seok Woo; Han, Sung Wook; Park, Chul Wook [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1996-07-01

    Measurement of human motion is important in the application of ergonomics. We developed a system which can measure body movement, especially= hand movement using advanced direct video measurement technology. This system has as dynamic accuracy with 1% error and the sampling rate to 6 - 10 Hz, and can analyse the trajectory and speed of the marker. The use of passive marker obviates the need for a marker telemetry system and minimize motion disruption. 18 refs., 4 tabs., 6 figs. (author)

  8. Radiologic total lung capacity measurement. Development and evaluation of a computer-based system

    Energy Technology Data Exchange (ETDEWEB)

    Seeley, G.W.; Mazzeo, J.; Borgstrom, M.; Hunter, T.B.; Newell, J.D.; Bjelland, J.C.

    1986-11-01

    The development of a computer-based radiologic total lung capacity (TLC) measurement system designed to be used by non-physician personnel is detailed. Four operators tested the reliability and validity of the system by measuring inspiratory PA and lateral pediatric chest radiographs with a Graf spark pen interfaced to a DEC VAX 11/780 computer. First results suggest that the ultimate goal of developing an accurate and easy to use TLC measurement system for non-physician personnel is attainable.

  9. Measurement system microdensitometer Joyce-Loebl and computer IBM-PC for quantitative evaluation of autoradiograms

    International Nuclear Information System (INIS)

    Chajecki, T.

    1992-01-01

    The description of measurement system microdensitometer Joyce-Loebl, computer IBM-PC interface are given in the report. This system gives the possibility to save and processing of autoradiograms quantity data. (author). 2 refs, 14 figs, 2 tabs

  10. Measuring value for money: a scoping review on economic evaluation of health information systems.

    Science.gov (United States)

    Bassi, Jesdeep; Lau, Francis

    2013-01-01

    To explore how key components of economic evaluations have been included in evaluations of health information systems (HIS), to determine the state of knowledge on value for money for HIS, and provide guidance for future evaluations. We searched databases, previously collected papers, and references for relevant papers published from January 2000 to June 2012. For selection, papers had to: be a primary study; involve a computerized system for health information processing, decision support, or management reporting; and include an economic evaluation. Data on study design and economic evaluation methods were extracted and analyzed. Forty-two papers were selected and 33 were deemed high quality (scores ≥ 8/10) for further analysis. These included 12 economic analyses, five input cost analyses, and 16 cost-related outcome analyses. For HIS types, there were seven primary care electronic medical records, six computerized provider order entry systems, five medication management systems, five immunization information systems, four institutional information systems, three disease management systems, two clinical documentation systems, and one health information exchange network. In terms of value for money, 23 papers reported positive findings, eight were inconclusive, and two were negative. We found a wide range of economic evaluation papers that were based on different assumptions, methods, and metrics. There is some evidence of value for money in selected healthcare organizations and HIS types. However, caution is needed when generalizing these findings. Better reporting of economic evaluation studies is needed to compare findings and build on the existing evidence base we identified.

  11. A novel fiber-optic measurement system for the evaluation of performances of neonatal pulmonary ventilators

    International Nuclear Information System (INIS)

    Battista, L; Scorza, A; Botta, F; Sciuto, S A

    2016-01-01

    Published standards for the performance evaluation of pulmonary ventilators are mainly directed to manufacturers rather than to end-users and often considered inadequate or not comprehensive. In order to contribute to overcome the problems above, a novel measurement system was proposed and tested with waveforms of mechanical ventilation by means of experimental trials carried out with infant ventilators typically used in neonatal intensive care units: the main quantities of mechanical ventilation in newborns are monitored, i.e. air flow rate, differential pressure and volume from infant ventilator are measured by means of two novel fiber-optic sensors (OFSs) developed and characterized by the authors, while temperature and relative humidity of air mass are obtained by two commercial transducers. The proposed fiber-optic sensors (flow sensor Q-OFS, pressure sensor P-OFS) showed measurement ranges of air flow and pressure typically encountered in neonatal mechanical ventilation, i.e. the air flow rate Q ranged from 3 l min −1 to 18 l min −1 (inspiratory) and from  −3 l min −1 to  −18 l min −1 (expiratory), the differential pressure ΔP ranged from  −15 cmH 2 O to 15 cmH2O. In each experimental trial carried out with different settings of the ventilator, outputs of the OFSs are compared with data from two reference sensors (reference flow sensor RF, reference pressure sensor RP) and results are found consistent: flow rate Q showed a maximum error between Q-OFS and RF up to 13 percent, with an output ratio Q RF /Q OFS of not more than 1.06  ±  0.09 (least square estimation, 95 percent confidence level, R 2 between 0.9822 and 0.9931). On the other hand the maximum error between P-OFS and RP on differential pressure ΔP was lower than 10 percent, with an output ratio ΔP RP /ΔP OFS between 0.977  ±  0.022 and 1.0  ±  0.8 (least square estimation, 95 percent confidence level, R 2 between 0.9864 and 0.9876). Despite the

  12. A novel fiber-optic measurement system for the evaluation of performances of neonatal pulmonary ventilators

    Science.gov (United States)

    Battista, L.; Scorza, A.; Botta, F.; Sciuto, S. A.

    2016-02-01

    Published standards for the performance evaluation of pulmonary ventilators are mainly directed to manufacturers rather than to end-users and often considered inadequate or not comprehensive. In order to contribute to overcome the problems above, a novel measurement system was proposed and tested with waveforms of mechanical ventilation by means of experimental trials carried out with infant ventilators typically used in neonatal intensive care units: the main quantities of mechanical ventilation in newborns are monitored, i.e. air flow rate, differential pressure and volume from infant ventilator are measured by means of two novel fiber-optic sensors (OFSs) developed and characterized by the authors, while temperature and relative humidity of air mass are obtained by two commercial transducers. The proposed fiber-optic sensors (flow sensor Q-OFS, pressure sensor P-OFS) showed measurement ranges of air flow and pressure typically encountered in neonatal mechanical ventilation, i.e. the air flow rate Q ranged from 3 l min-1 to 18 l min-1 (inspiratory) and from  -3 l min-1 to  -18 l min-1 (expiratory), the differential pressure ΔP ranged from  -15 cmH2O to 15 cmH2O. In each experimental trial carried out with different settings of the ventilator, outputs of the OFSs are compared with data from two reference sensors (reference flow sensor RF, reference pressure sensor RP) and results are found consistent: flow rate Q showed a maximum error between Q-OFS and RF up to 13 percent, with an output ratio Q RF/Q OFS of not more than 1.06  ±  0.09 (least square estimation, 95 percent confidence level, R 2 between 0.9822 and 0.9931). On the other hand the maximum error between P-OFS and RP on differential pressure ΔP was lower than 10 percent, with an output ratio ΔP RP/ΔP OFS between 0.977  ±  0.022 and 1.0  ±  0.8 (least square estimation, 95 percent confidence level, R 2 between 0.9864 and 0.9876). Despite the possible improvements

  13. Evaluation Framework Based on Fuzzy Measured Method in Adaptive Learning Systems

    Science.gov (United States)

    Ounaies, Houda Zouari; Jamoussi, Yassine; Ben Ghezala, Henda Hajjami

    2008-01-01

    Currently, e-learning systems are mainly web-based applications and tackle a wide range of users all over the world. Fitting learners' needs is considered as a key issue to guaranty the success of these systems. Many researches work on providing adaptive systems. Nevertheless, evaluation of the adaptivity is still in an exploratory phase.…

  14. Validation, verification and evaluation of a Train to Train Distance Measurement System by means of Colored Petri Nets

    International Nuclear Information System (INIS)

    Song, Haifeng; Liu, Jieyu; Schnieder, Eckehard

    2017-01-01

    Validation, verification and evaluation are necessary processes to assure the safety and functionality of a system before its application in practice. This paper presents a Train to Train Distance Measurement System (TTDMS), which can provide distance information independently from existing onboard equipment. Afterwards, we proposed a new process using Colored Petri Nets to verify the TTDMS system functional safety, as well as to evaluate the system performance. Three main contributions are carried out in the paper: Firstly, this paper proposes a formalized TTDMS model, and the model correctness is validated using state space analysis and simulation-based verification. Secondly, corresponding checking queries are proposed for the purpose of functional safety verification. Further, the TTDMS performance is evaluated by applying parameters in the formal model. Thirdly, the reliability of a functional prototype TTDMS is estimated. It is found that the procedure can cooperate with the system development, and both formal and simulation-based verifications are performed. Using our process to evaluate and verify a system is easier to read and more reliable compared to executable code and mathematical methods. - Highlights: • A new Train to Train Distance Measurement System. • New approach verifying system functional safety and evaluating system performance by means of CPN. • System formalization using the system property concept. • Verification of system functional safety using state space analysis. • Evaluation of system performance applying simulation-based analysis.

  15. Evaluation framework based on fuzzy measured method in adaptive learning systems

    OpenAIRE

    Houda Zouari Ounaies, ,; Yassine Jamoussi; Henda Hajjami Ben Ghezala

    2008-01-01

    Currently, e-learning systems are mainly web-based applications and tackle a wide range of users all over the world. Fitting learners’ needs is considered as a key issue to guaranty the success of these systems. Many researches work on providing adaptive systems. Nevertheless, evaluation of the adaptivity is still in an exploratory phase. Adaptation methods are a basic factor to guaranty an effective adaptation. This issue is referred as meta-adaptation in numerous researches. In our research...

  16. Evaluation of irradiation measurements on tilted planes at PV systems in the Netherlands

    NARCIS (Netherlands)

    Betcke, J.W.H.; Dijk, V.A.P. van; Ramaekers, L.A.M.; Zolingen, R.J.C. van

    1998-01-01

    Monitoring data of Dutch PV systems in the field show lower values for the measured global irradiation in the array plane than expected from model calculatations. Since the locations of the PV systems contain obstacles, we expect that shielding of diffuse irradiation may cause the difference. For

  17. Basic evaluation of signal transmission in a real-time internal radiation dose measurement system

    International Nuclear Information System (INIS)

    Shinohe, K.; Takura, T.; Sato, F.; Matsuki, H.; Yamada, S.; Sato, T.

    2009-01-01

    In radiation therapy, excessive exposure to radiation occurs because the dose actually delivered to the tumor is not known. As a result, a patient suffers from side effects. To solve this problem, a system is needed in which the delivered dose is measured inside the body and the dose data are transmitted from inside to outside of the body during radiation therapy. If such a system is realized, it will be possible to treat cancer safely and effectively. The proposed real-time internal radiation dose measurement system consists of an implantable dosimeter, a wireless communication system, and a wireless feeding system. In this study, a wireless communication system that uses magnetic fields was investigated. As a result, a communication distance of 200 mm was obtained. It was confirmed that radiation dose data could be transmitted outside the body when the communication distance is the required 200 mm. (author)

  18. Evaluation of Pachymetric Measurements with Scheimpflug Photography-Based System and Optical Coherence Tomography Pachymetry at Different Stages of Keratoconus

    Directory of Open Access Journals (Sweden)

    Betül İlkay Sezgin Akçay

    2014-01-01

    Full Text Available The aim of this study was to compare the central and peripheral pachymetric measurements determined with Sirius system and Visante OCT and evaluate the agreement between them at different stages of keratoconus. Measurements were not significantly different in all patients and subgroups and showed high correlation for the corneal thicknesses of the entire cornea in different stages of keratoconus.

  19. Evaluation of accountability measurements

    International Nuclear Information System (INIS)

    Cacic, C.G.

    1988-01-01

    The New Brunswick Laboratory (NBL) is programmatically responsible to the U.S. Department of Energy (DOE) Office of Safeguards and Security (OSS) for providing independent review and evaluation of accountability measurement technology in DOE nuclear facilities. This function is addressed in part through the NBL Safegaurds Measurement Evaluation (SME) Program. The SME Program utilizes both on-site review of measurement methods along with material-specific measurement evaluation studies to provide information concerning the adequacy of subject accountability measurements. This paper reviews SME Program activities for the 1986-87 time period, with emphasis on noted improvements in measurement capabilities. Continued evolution of the SME Program to respond to changing safeguards concerns is discussed

  20. A discussion of techniques used in defining the Interactive Measurement Evaluation and Control System at Rocky Flats

    International Nuclear Information System (INIS)

    Greer, B.K.; Hunt, V.; Schweitzer, M.F.

    1983-01-01

    This paper describes both the general methodology used to study the current needs for a measurement control and evaluation system at Rocky Flats Plant and the recommendations for implementation into the Interactive Measurement Evaluation and Control System (IMECS). The study resulted in a clear assessment of the current system and recommendations for the system which will be its replacement. To arrive at the recommendations, the authors used a formal analysis approach that is based on an in-depth study of the measurement evaluation and control problems and user needs. The problems and needs were defined by interviews with present and potential users of this kind of system throughout the nuclear industry. Some of the recommendations are to provide: timely sample measurement feedback; representative measurement error estimates; a history data base of sample measurements To meet the user needs, the new system will: be interactive with user selection menus; use standards which cover the range of application; facilitate historical analysis of sample data and bookkeeping. The implementation of this program is projected to be more cost effective than the current program. Also included are the authors' recommendations to those involved in the design of a system of similar large magnitude

  1. Measuring the Usability of Augmented Reality e-Learning Systems: A User-Centered Evaluation Approach

    Science.gov (United States)

    Pribeanu, Costin; Balog, Alexandru; Iordache, Dragoş Daniel

    The development of Augmented Reality (AR) systems is creating new challenges and opportunities for the designers of e-learning systems. The mix of real and virtual requires appropriate interaction techniques that have to be evaluated with users in order to avoid usability problems. Formative usability aims at finding usability problems as early as possible in the development life cycle and is suitable to support the development of such novel interactive systems. This work presents an approach to the user-centered usability evaluation of an e-learning scenario for Biology developed on an Augmented Reality educational platform. The evaluation has been carried on during and after a summer school held within the ARiSE research project. The basic idea was to perform usability evaluation twice. In this respect, we conducted user testing with a small number of students during the summer school in order to get a fast feedback from users having good knowledge in Biology. Then, we repeated the user testing in different conditions and with a relatively larger number of representative users. In this paper we describe both experiments and compare the usability evaluation results.

  2. Development of custom measurement system for biomechanical evaluation of independent wheelchair transfers.

    Science.gov (United States)

    Koontz, Alicia M; Lin, Yen-Sheng; Kankipati, Padmaja; Boninger, Michael L; Cooper, Rory A

    2011-01-01

    This study describes a new custom measurement system designed to investigate the biomechanics of sitting-pivot wheelchair transfers and assesses the reliability of selected biomechanical variables. Variables assessed include horizontal and vertical reaction forces underneath both hands and three-dimensional trunk, shoulder, and elbow range of motion. We examined the reliability of these measures between 5 consecutive transfer trials for 5 subjects with spinal cord injury and 12 nondisabled subjects while they performed a self-selected sitting pivot transfer from a wheelchair to a level bench. A majority of the biomechanical variables demonstrated moderate to excellent reliability (r > 0.6). The transfer measurement system recorded reliable and valid biomechanical data for future studies of sitting-pivot wheelchair transfers.We recommend a minimum of five transfer trials to obtain a reliable measure of transfer technique for future studies.

  3. Virtual tape measure for the operating microscope: system specifications and performance evaluation.

    Science.gov (United States)

    Kim, M Y; Drake, J M; Milgram, P

    2000-01-01

    The Virtual Tape Measure for the Operating Microscope (VTMOM) was created to assist surgeons in making accurate 3D measurements of anatomical structures seen in the surgical field under the operating microscope. The VTMOM employs augmented reality techniques by combining stereoscopic video images with stereoscopic computer graphics, and functions by relying on an operator's ability to align a 3D graphic pointer, which serves as the end-point of the virtual tape measure, with designated locations on the anatomical structure being measured. The VTMOM was evaluated for its baseline and application performances as well as its application efficacy. Baseline performance was determined by measuring the mean error (bias) and standard deviation of error (imprecision) in measurements of non-anatomical objects. Application performance was determined by comparing the error in measuring the dimensions of aneurysm models with and without the VTMOM. Application efficacy was determined by comparing the error in selecting the appropriate aneurysm clip size with and without the VTMOM. Baseline performance indicated a bias of 0.3 mm and an imprecision of 0.6 mm. Application bias was 3.8 mm and imprecision was 2.8 mm for aneurysm diameter. The VTMOM did not improve aneurysm clip size selection accuracy. The VTMOM is a potentially accurate tool for use under the operating microscope. However, its performance when measuring anatomical objects is highly dependent on complex visual features of the object surfaces. Copyright 2000 Wiley-Liss, Inc.

  4. Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS) Science Plan

    Energy Technology Data Exchange (ETDEWEB)

    de Boer, G [University of Colorado, Boulder/CIRES; Argrow, B [University of Colorado; Bland, G [NASA - Goddard Space Flight Center - Wallops Flight Facility; Elston, J [University of Colorado, Boulder; Lawrence, D [University of Colorado; Maslanik, J [University of Colorado; Palo, S [University of Colorado; Tschudi, M [NCAR

    2015-12-01

    The use of unmanned aerial systems (UAS) is becoming increasingly popular for a variety of applications. One way in which these systems can provide revolutionary scientific information is through routine measurement of atmospheric conditions, particularly properties related to clouds, aerosols, and radiation. Improved understanding of these topics at high latitudes, in particular, has become very relevant because of observed decreases in ice and snow in polar regions.

  5. Towards unified performance measures for evaluating nuclear safeguard systems: mathematical foundations and formal comparison of existing models

    International Nuclear Information System (INIS)

    Corynen, G.C.

    1979-01-01

    An important step in the analysis of large-scale systems is the development of economical and meaningful measures of system performance. In the literature on analysis of nuclear safeguard systems, many performance measures have been advanced, but their interrelationships and their relevance to overall system objectives have not received attention commensurate with the effort spent in developing detailed safeguard models. The work reported here is an attempt to improve the development and evaluation of performance measures for nuclear safeguard systems. This work falls into three main areas. First, we develop a new framework which provides an initial basis for defining and structuring performance measures. To demonstrate that this framework allows a clear understanding of the purposes of nuclear safeguard systems, we employ it to state various safeguard questions clearly and concisely. The framework reflects the rough subsystem structure of safeguard systems - the detection and response subsystems - and formally accommodates various safeguard models. We especially emphasize two of these models which are under development at Lawrence Livermore Laboratory, the structured assessment approach (SAA) and the systems vulnerability assessment method (SVAM). Second, we examine some performance measures presently used in the nuclear safeguards area and in reliability theory in general. Some of these we accept and modify to obtain system performance measures that are an additive combination of subsystem performance measures, a very convenient form indeed. Others we reject as impractical and meaningless. Finally, we determine some common features between the SAA and SVAM models by formally comparing these models in our framework

  6. Evaluating Performance Measurement Systems in Nonprofit Agencies: The Program Accountability Quality Scale (PAQS).

    Science.gov (United States)

    Poole, Dennis L.; Nelson, Joan; Carnahan, Sharon; Chepenik, Nancy G.; Tubiak, Christine

    2000-01-01

    Developed and field tested the Performance Accountability Quality Scale (PAQS) on 191 program performance measurement systems developed by nonprofit agencies in central Florida. Preliminary findings indicate that the PAQS provides a structure for obtaining expert opinions based on a theory-driven model about the quality of proposed measurement…

  7. Measuring Social Relationships in Different Social Systems: The Construction and Validation of the Evaluation of Social Systems (EVOS) Scale

    Science.gov (United States)

    Aguilar-Raab, Corina; Grevenstein, Dennis; Schweitzer, Jochen

    2015-01-01

    Social interactions have gained increasing importance, both as an outcome and as a possible mediator in psychotherapy research. Still, there is a lack of adequate measures capturing relational aspects in multi-person settings. We present a new measure to assess relevant dimensions of quality of relationships and collective efficacy regarding interpersonal interactions in diverse personal and professional social systems including couple partnerships, families, and working teams: the EVOS. Theoretical dimensions were derived from theories of systemic family therapy and organizational psychology. The study was divided in three parts: In Study 1 (N = 537), a short 9-item scale with two interrelated factors was constructed on the basis of exploratory factor analysis. Quality of relationship and collective efficacy emerged as the most relevant dimensions for the quality of social systems. Study 2 (N = 558) confirmed the measurement model using confirmatory factor analysis and established validity with measures of family functioning, life satisfaction, and working team efficacy. Measurement invariance was assessed to ensure that EVOS captures the same latent construct in all social contexts. In Study 3 (N = 317), an English language adaptation was developed, which again confirmed the original measurement model. The EVOS is a theory-based, economic, reliable, and valid measure that covers important aspects of social relationships, applicable for different social systems. It is the first instrument of its kind and an important addition to existing measures of social relationships and related outcome measures in therapeutic and other counseling settings involving multiple persons. PMID:26200357

  8. Measuring Social Relationships in Different Social Systems: The Construction and Validation of the Evaluation of Social Systems (EVOS Scale.

    Directory of Open Access Journals (Sweden)

    Corina Aguilar-Raab

    Full Text Available Social interactions have gained increasing importance, both as an outcome and as a possible mediator in psychotherapy research. Still, there is a lack of adequate measures capturing relational aspects in multi-person settings. We present a new measure to assess relevant dimensions of quality of relationships and collective efficacy regarding interpersonal interactions in diverse personal and professional social systems including couple partnerships, families, and working teams: the EVOS. Theoretical dimensions were derived from theories of systemic family therapy and organizational psychology. The study was divided in three parts: In Study 1 (N = 537, a short 9-item scale with two interrelated factors was constructed on the basis of exploratory factor analysis. Quality of relationship and collective efficacy emerged as the most relevant dimensions for the quality of social systems. Study 2 (N = 558 confirmed the measurement model using confirmatory factor analysis and established validity with measures of family functioning, life satisfaction, and working team efficacy. Measurement invariance was assessed to ensure that EVOS captures the same latent construct in all social contexts. In Study 3 (N = 317, an English language adaptation was developed, which again confirmed the original measurement model. The EVOS is a theory-based, economic, reliable, and valid measure that covers important aspects of social relationships, applicable for different social systems. It is the first instrument of its kind and an important addition to existing measures of social relationships and related outcome measures in therapeutic and other counseling settings involving multiple persons.

  9. Self-Evaluation of PANDA-FBG Based Sensing System for Dynamic Distributed Strain and Temperature Measurement.

    Science.gov (United States)

    Zhu, Mengshi; Murayama, Hideaki; Wada, Daichi

    2017-10-12

    A novel method is introduced in this work for effectively evaluating the performance of the PANDA type polarization-maintaining fiber Bragg grating (PANDA-FBG) distributed dynamic strain and temperature sensing system. Conventionally, the errors during the measurement are unknown or evaluated by using other sensors such as strain gauge and thermocouples. This will make the sensing system complicated and decrease the efficiency since more than one kind of sensor is applied for the same measurand. In this study, we used the approximately constant ratio of primary errors in strain and temperature measurement and realized the self-evaluation of the sensing system, which can significantly enhance the applicability, as well as the reliability in strategy making.

  10. Measurement system for evaluation of the muon chambers for the LHCb experiment

    International Nuclear Information System (INIS)

    Nobrega, Rafael A.; Pinci, Davide

    2011-01-01

    In a detector with the complexity of the LHCb, where only for the muon system more than 1300 chambers, divided into 20 different types, will be used, resulting on more than 120 k channels to be readout, it is of crucial importance to study the many types of chambers to create a complete knowledge of the detector operation and to guarantee a high-quality performance during the experiment. To make it possible, a complete setup was built and a C++ based software was developed to carry out a set of measurements on the full-equipped chambers of the LHCb muon detector. The setup is made of front-end control electronics, high-voltage supply and acquisition circuitry while the software, running on a PC, remotely controls each element of the system and implements a number of automatized procedures to assess the main characteristics of the chambers. The main advantages of this system are its versatility and speed of measurement which are crucial to the experiment since there is the need to characterize every single chamber before final installation. Moreover, in this work it was proposed to measure the starting knee of the high-voltage operational plateau without the use of an external trigger by making use of the internal structure of the chambers. Two laboratories were prepared at CERN (European Laboratory for Particle Physics) to receive this system; one used to test chambers arrived from the CERN itself and the PNPI (Petersburg Nuclear Physics Institute) production sites, and one to test the chambers arrived from the INFN (National Institute of Nuclear Physics) production sites. In this document, the hardware and software setup will be presented together with the measurement-oriented implementations.

  11. Evaluating the accuracy of tooth color measurement by combining the Munsell color system and dental colorimeter.

    Science.gov (United States)

    Chang, Jiun-Yao; Chen, Wen-Cheng; Huang, Ta-Ko; Wang, Jen-Chyan; Fu, Po-Sung; Chen, Jeng-Huey; Hung, Chun-Cheng

    2012-09-01

    As we pay increasing attention to dental aesthetics, tooth color matching has become an important part of daily dental practice. This aim of this study was to develop a method to enhance the accuracy of a tooth color matching machine. The Munsell color tabs in the range of natural human teeth were measured using a tooth color measuring machine (ShadeEye NCC). The machine's accuracy was analyzed using an analysis of variance test and a Tukey post-hoc test. When matching the Munsell color tabs with the ShadeEye NCC colorimeter, settings of Chroma greater than 6 and Value less than 4 showed unacceptable clinical results. When the CIELAB mode was used, the a* value (which represents the red-green axis in the Commission Internationale de l'Eclairage color space) made no significant difference (p=0.84), the L* value (which represents the lightness) resulted in a negative correlation, and the b* value (which represents the yellow-blue axis) resulted in a positive correlation with ΔE. When the Munsell color tabs and the Vitapan were measured in the same mode and compared, the inaccuracies showed that the Vitapan was not a proper tool for evaluating the stability and accuracy of ShadeEye NCC. By knowing the limitations of the machine, we evaluated the data using the Munsell color tabs; shade beyond the acceptable range should be reevaluated using a visual shade matching method, or if measured by another machine, this shade range should be covered to obtain more accurate results. Copyright © 2012. Published by Elsevier B.V.

  12. Experiments in high energy elementary particle physics and processing of photographically filed data with the aid of a measuring and evaluating system

    Energy Technology Data Exchange (ETDEWEB)

    Kirst, H [Akademie der Wissenschaften der DDR, Berlin-Zeuthen. Inst. fuer Hochenergiephysik

    1977-01-01

    The measuring and evaluating system includes pattern recognition and measuring instruments as well as a processor for data evaluation and checking procedures. The program chart and the application to evaluating photographs of particle tracks from high energy physics experiments are mentioned. The time-sharing effect of such systems in data evaluation is emphasized.

  13. Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure.

    Science.gov (United States)

    Coorevits, L; Van den Abeele, A-M

    2015-07-01

    The yield of blood cultures is proportional to the volume of blood cultured. We evaluated an automatic blood volume monitoring system, recently developed by Becton Dickinson within its BACTEC EpiCenter module, that calculates mean volumes of negative aerobic bottles and generates boxplots and histograms. First, we evaluated the filling degree of 339 aerobic glass blood cultures by calculating the weight-based volume for each bottle. A substantial amount of the bottles (48.3%) were inadequately filled. Evaluation of the accuracy of the monitoring system showed a mean bias of -1.4 mL (-15.4%). Additional evaluation, using the amended software on 287 aerobic blood culture bottles, resulted in an acceptable mean deviation of -0.3 mL (-3.3%). The new software version was also tested on 200 of the recently introduced plastic bottles, which will replace the glass bottles in the near future, showing a mean deviation of +2.8 mL (+26.7%). In conclusion, the mean calculated volumes can be used for the training of a single phlebotomist. However, filling problems appear to be masked when using them for phlebotomist groups or on wards. Here, visual interpretation of boxplots and histograms can serve as a useful tool to observe the spread of the filling degrees and to develop a continuous improvement program. Re-adjustment of the software has proven to be necessary for use with plastic bottles. Due to our findings, BD has developed further adjustments to the software for validated use with plastic bottles, which will be released soon.

  14. Review and Evaluation of Hand–Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces

    Directory of Open Access Journals (Sweden)

    Ren G. Dong

    2015-09-01

    Full Text Available The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC system and an anatomically based biodynamic (BD system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study.

  15. Review and Evaluation of Hand–Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces

    Science.gov (United States)

    Dong, Ren G.; Sinsel, Erik W.; Welcome, Daniel E.; Warren, Christopher; Xu, Xueyan S.; McDowell, Thomas W.; Wu, John Z.

    2015-01-01

    The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study. PMID:26929824

  16. Review and Evaluation of Hand-Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces.

    Science.gov (United States)

    Dong, Ren G; Sinsel, Erik W; Welcome, Daniel E; Warren, Christopher; Xu, Xueyan S; McDowell, Thomas W; Wu, John Z

    2015-09-01

    The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study.

  17. Evaluation of an automated assay system to measure soil radionuclides by L x-ray and gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Nyhan, J.W.; Drennon, B.J.; Crowell, J.M.

    1982-08-01

    An automated radionuclide assay system for conducting soil radioassays using L x-ray and gamma-ray spectrometry was evaluated. Wet chemistry assay procedures were shown to be considerably more time consuming than similar analyses of soil on this radionuclide assay system. The detection limits of 241 Am and plutonium were determined, as well as the reproducibility of radionuclide assay results. The L x-ray spectrometric measurements were compared with radiochemical analyses on several tuff samples. The assay system's intrinsic germanium detector was found to respond linearly to varying low concentrations of 241 Am and plutonium, both of which were easily detected in the presence of elevated concentrations of 137 Cs

  18. Performance measurement, modeling, and evaluation of integrated concurrency control and recovery algorithms in distributed data base systems

    Energy Technology Data Exchange (ETDEWEB)

    Jenq, B.C.

    1986-01-01

    The performance evaluation of integrated concurrency-control and recovery mechanisms for distributed data base systems is studied using a distributed testbed system. In addition, a queueing network model was developed to analyze the two phase locking scheme in the distributed testbed system. The combination of testbed measurement and analytical modeling provides an effective tool for understanding the performance of integrated concurrency control and recovery algorithms in distributed database systems. The design and implementation of the distributed testbed system, CARAT, are presented. The concurrency control and recovery algorithms implemented in CARAT include: a two phase locking scheme with distributed deadlock detection, a distributed version of optimistic approach, before-image and after-image journaling mechanisms for transaction recovery, and a two-phase commit protocol. Many performance measurements were conducted using a variety of workloads. A queueing network model is developed to analyze the performance of the CARAT system using the two-phase locking scheme with before-image journaling. The combination of testbed measurements and analytical modeling provides significant improvements in understanding the performance impacts of the concurrency control and recovery algorithms in distributed database systems.

  19. Providers' perceptions of the implementation of a performance measurement system for substance abuse treatment: A process evaluation of the Service Quality Measures initiative.

    Science.gov (United States)

    Myers, Bronwyn; Williams, Petal Petersen; Johnson, Kim; Govender, Rajen; Manderscheid, Ron; Koch, J Randy

    2016-02-22

    In South Africa, concerns exist about the quality of substance abuse treatment. We developed a performance measurement system, known as the Service Quality Measures (SQM) initiative, to monitor the quality of treatment and assess efforts to improve quality of care. In 2014, the SQM system was implemented at six treatment sites to evaluate how implementation protocols could be improved in preparation for wider roll-out. To describe providers' perceptions of the feasibility and acceptability of implementing the SQM system, including barriers to and facilitators of implementation. We conducted 15 in-depth interviews (IDIs) with treatment providers from six treatment sites (two sites in KwaZulu-Natal and four in the Western Cape). Providers were asked about their experiences in implementing the system, the perceived feasibility of the system, and barriers to implementation. All IDIs were audio-recorded and transcribed verbatim. A framework approach was used to analyse the data. Providers reported that the SQM system was feasible to implement and acceptable to patients and providers. Issues identified through the IDIs included a perceived lack of clarity about sequencing of key elements in the implementation of the SQM system, questions on integration of the system into clinical care pathways, difficulties in tracking patients through the system, and concerns about maximising patient participation in the process. Findings suggest that the SQM system is feasible to implement and acceptable to providers, but that some refinements to the implementation protocols are needed to maximise patient participation and the likelihood of sustained implementation.

  20. Current distribution evaluation of dye-sensitized solar cell using HTS-SQUID-based magnetic measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Kenji, E-mail: Sakai-k@okayama-u.ac.jp; Tanaka, Kohei; Kiwa, Toshihiko; Tsukada, Keiji

    2016-11-15

    Highlights: • Current distribution and direction of dye-sensitized solar cell (DSSC) was measured. • Electrical current flowing in the indium tin oxide (ITO) glass substrate was uniform. • The distribution of electrical current depended on I–V characteristic. • Current direction changed when the performance of DSSC is low. - Abstract: The current flowing inside a dye-sensitized solar cell (DSSC) was measured using a high-temperature superconductor superconducting quantum interference device (HTS-SQUID)-based magnetic measurement system. Further, a new evaluation method of the DSSC, which is difficult to measure using the conventional method, was investigated to improve the characteristics of the DSSC. The tangential components of the magnetic field generated from the DSSC were measured using two HTS-SQUIDs, and the intensity and direction related to the electrical current were obtained by the measured magnetic field. The DSSCs prepared with different dyes and catalytic substances showed different current-intensity mapping. The current direction was different for the DSSC with low performance. In addition, the current flowing in the ITO layer of the ITO glass substrate was also measured and the results confirmed that it had uniform distribution. These results show that the current mapping and the direction of the electrical current depend on the internal factors of the DSSC, and the detection of the magnetic field distribution generated from it is expected to lead to its new evaluation method.

  1. Evaluation of Performance Measurement Instruments on Their Use for Food Quality Systems

    NARCIS (Netherlands)

    Spiegel, van der M.; Luning, P.A.; Ziggers, G.W.; Jongen, W.M.F.

    2004-01-01

    Due to regular challenges of food safety, consumers put high demands on the performance of food quality systems. To deal with these requirements, food manufacturers need effective quality management. Performance of food quality systems can be partly realized by quality assurance systems, such as

  2. Evaluation of Performance Measurement Instruments on their use for Food Quality Systems

    NARCIS (Netherlands)

    Spiegel, M. van der; Luning, P.A.; Ziggers, G.W.; Jongen, W.M.F.

    2005-01-01

    Due to regular challenges of food safety, consumers put high demands on the performance of food quality systems. To deal with these requirements, food manufacturers need effective quality management. Performance of food quality systems can be partly realized by quality assurance systems, such as

  3. Innovative Nuclear Energy Systems: State-of-the Art Survey on Evaluation and Aggregation Judgment Measures Applied to Performance Comparison

    Directory of Open Access Journals (Sweden)

    Vladimir Kuznetsov

    2015-04-01

    Full Text Available This paper summarizes the experience gained in the application of multi-criteria decision making and uncertainty treatment methods to a comparative assessment of nuclear energy systems and related nuclear fuel cycles. These judgment measures provide a means for comprehensive evaluation according to different conflicting criteria, such as costs, benefits and risks, which are inevitably associated with the deployment of advanced technologies. Major findings and recommendations elaborated in international and national projects and studies are reviewed and discussed. A careful analysis is performed for multi-criteria comparative assessment of nuclear energy systems and nuclear fuel cycles on the basis of various evaluation and screening results. The purpose of this paper is to discuss the lessons learned, to share the identified solutions, and indicate promising future directions.

  4. Round robins of solar cells to evaluate measurement systems of different european research institutes

    Energy Technology Data Exchange (ETDEWEB)

    Manshanden, P.; Van der Brog, N.J.C.M. [ECN Solar, Westerduinweg 3, 1755 LE Petten (Netherlands); Bliss, M.; Mihaylov, B.; Gottschlag, R. [CREST, Holywell Park MBG GJ/Gx, Loughborough Univeristy, Leicestershire, LE11 3TU (United Kingdom); Izzi, M.; Tucci, M. [ENEA CASACCIA, Via Anguillarese 301, 00123 Roma (Italy); Roca, F.; Pellegrino, M.; Romano, A.; Graditi, G. [ENEA PORTICI, P. le E. Fermi Localita Granatello, 80055 Portici Napoli (Italy); Hohl-Ebinger, J.; Warta, W. [Fraunhofer ISE, Berliner Allee 30, 79110 Freiburg (Germany); Debucquoy, M.; El Daif, O.; Gordon, I. [IMEC, Kapeldreef 75, B-3001 Heverlee (Belgium); Champliaud, J.; Jouini, A. [INES, 50 avenue du lac Leman, BP 332, 73377, Le Bourget-du-Lac (France); Glatz-Reichenbach, J. [ISC, Rudolf Diesel Str. 15, D-78467 Konstanz (Germany); Bothe, K. [ISFH, Am Ohrberg 1, 31860 Emmerthal (Germany); Herguth, A. [University of Konstanz, Universitaetsstrasse 10, 78457 Konstanz (Germany)

    2013-10-15

    Determination of the solar cell efficiency and internal quantum efficiency are standard characterization methods used by the majority of research institutes. Random errors can be assessed by institutes themselves by repeated measurements, but systematic deviations cannot be assessed without comparisons with other institutes. The comparisons were performed for illuminated IV, spectral response and reflection measurements. The results were split into systematic differences between the partners and random differences within an institute for a single measurement session. The total differences are: J{sub sc}: 0.27 A, V{sub oc}: 8.5 mV, FF: 2.4 %, {eta}: 0.6%, spectral response: 0.14 A/W and reflection: 0.08. For all measurement methods, the systematic differences exceeded the random differences. The major component for the systematic differences is likely the reference device, but also temperature control, contacting scheme and setup differences play a part.

  5. Analytical evaluation of a new point of care system for measuring cardiac Troponin I

    NARCIS (Netherlands)

    Kemper, D.W.; Semjonow, V.; de Theije, F.; Keizer, D.; van Lippen, L.; Mair, J.; Wille, B.; Christ, M.; Geijer, F.; Hausfater, P.; Pariente, D.; Scharnhorst, V.; Curvers, J.; Nieuwenhuis, J.

    2017-01-01

    OBJECTIVES: Point-of-care cardiac troponin testing with adequate analytical performances has the potential to improve chest pain patients flow in the emergency department. We present the analytical evaluation of the newly developed Philips Minicare cTnI point-of-care immunoassay. DESIGN & METHODS:

  6. Selecting Growth Measures for Use in School Evaluation Systems: Should Proportionality Matter?

    Science.gov (United States)

    Ehlert, Mark; Koedel, Cory; Parsons, Eric; Podgursky, Michael

    2016-01-01

    The specifics of how growth models should be constructed and used for educational evaluation is a topic of lively policy debate in states and school districts nationwide. In this article, we take up the question of model choice--framed within a policy context--and examine three competing approaches. The first approach, reflected in the popular…

  7. Dose estimation and evaluation of protector measures for a power plant's accidents scenario, using geographical information system

    International Nuclear Information System (INIS)

    Costa, E.M.; Biagio, R.M.S.; Alves, R.N.

    1999-01-01

    Since the initial phase of a project of a nuclear plant several environmental studies are carried out, and a considerable amount of relevant information is generated. Therefore, there is an increasing need of an integrated analysis of this information in order to better evaluate the potential impact associated to hypothetical accident scenarios of such plants. This paper presents a case-study, in which a hypothetical accident scenario is analysed taking into account the environmental and populational information of the Brazilian nuclear power plants region by using a geographical information system. Important areas for planning of protective measures are identified to provide a basis for further analysis. (author)

  8. Key Performance Indicators Evaluation and Performance Measurement in Dry Port-Seaport System: A Multi Criteria Approach

    Directory of Open Access Journals (Sweden)

    Fatimazahra BENTALEB

    2015-12-01

    Full Text Available Dry port-seaport services are key elements of a multimodal transport. They represent the needed infrastructure for its development. In this case, evaluating and improving their performance is necessary to achieve international competitiveness. The purpose of this paper is to develop a new model of performance measurement for the dry port-seaport system. To this aim, we have consolidated available researches and existing studies in order to identify and develop our proposed model framework. In this paper, a multi-criteria hierarchical model framework using MACBETH for dry port-seaport system has been developed. This framework can be used by managers at different levels of the system. The proposed model has been developed by exploring measurement gaps in multimodal transport field and by discovering prospective options from this area. The results and the methodology are practical. We obtain the global performance level of our involved system using our methodology, which can help managers in taken decisions and increase global performance of this system.

  9. IMPROVEMENT OF MANUFACTURING PERFORMANCE MEASUREMENT SYSTEM AND EVALUATION OF OVERALL RESOURCE EFFECTIVENESS

    OpenAIRE

    Karuppana Gounder Eswaramurthi; Pidugun Venkatachalam Mohanram

    2013-01-01

    In the present highly competitive business environment, well run organizations continually strive to enhance their capabilities to create excellent value for the customers by improving the cost effectiveness of the operations. Significant improvement has taken place in the management of resources associated with manufacturing systems, to reduce the wastage of resources. The Total Productive Maintenance (TPM) concept provides a quantitative metric-Overall Equipment Effectiveness (OEE), for mea...

  10. Evaluation Use in Evaluation Systems

    DEFF Research Database (Denmark)

    Højlund, Steven

    2014-01-01

    This article investigates the European Union’s evaluation system and its conduciveness to evaluation use. Taking the European Commission’s LIFE programme as its case, the article makes an empirical contribution to an emerging focus in the literature on the importance of organization...... and institutions when analyzing evaluation use. By focusing on the European Union’s evaluation system the article finds that evaluation use mainly takes place in the European Commission and less so in the European Parliament and the European Council. The main explanatory factors enabling evaluation use relate...... to the system’s formalization of evaluation implementation and use; these factors ensure evaluation quality, timeliness and capacity in the Commission. At the same time, however, the system’s formalization also impedes evaluation use, reducing the direct influence of evaluations on policy-making and effectively...

  11. Web-Based Evaluation System to Measure Learning Effectiveness in Kampo Medicine

    Directory of Open Access Journals (Sweden)

    Norio Iizuka

    2016-01-01

    Full Text Available Measuring the learning effectiveness of Kampo Medicine (KM education is challenging. The aim of this study was to develop a web-based test to measure the learning effectiveness of KM education among medical students (MSs. We used an open-source Moodle platform to test 30 multiple-choice questions classified into 8-type fields (eight basic concepts of KM including “qi-blood-fluid” and “five-element” theories, on 117 fourth-year MSs. The mean (±standard deviation [SD] score on the web-based test was 30.2±11.9 (/100. The correct answer rate ranged from 17% to 36%. A pattern-based portfolio enabled these rates to be individualized in terms of KM proficiency. MSs with scores higher (n=19 or lower (n=14 than mean ± 1SD were defined as high or low achievers, respectively. Cluster analysis using the correct answer rates for the 8-type field questions revealed clear divisions between high and low achievers. Interestingly, each high achiever had a different proficiency pattern. In contrast, three major clusters were evident among low achievers, all of whom responded with a low percentage of or no correct answers. In addition, a combination of three questions accurately classified high and low achievers. These findings suggest that our web-based test allows individual quantitative assessment of the learning effectiveness of KM education among MSs.

  12. Evaluation of a measurement system for Uranium electrodeposition control to radiopharmaceuticals production

    International Nuclear Information System (INIS)

    Tufic Madi Filho; Adonis Marcelo Saliba Silva; Jose Patricio Nahuel Cardenas; Maria da Conceicao Costa Pereira; Valdir Maciel Lopes; Alexandre, P. S.; Diogo, F. S.; Rafael, T. P.; Vitor, O. A; Anderson, F. L.; Lucas, R. S.; Brianna, S.; Eduardo, L. C.

    2015-01-01

    For 2016, studies by international bodies forecast a crisis in the supply of Molybdenum ( 99 Mo), which is the generator of 99m Tc, widely used for medical diagnoses and treatments. As a result, many countries are making efforts to prevent this crisis. Brazil is developing the Brazilian Multipurpose Reactor (RMB) project, under the responsibility of the National Nuclear Energy Commission (CNEN). The RMB is a nuclear reactor for research and production of radioisotopes used in the production of radiopharmaceuticals and radioactive sources, broadly used in industrial and research areas in Brazil. Electrodeposition of uranium is a common practice to create samples for alpha spectrometry and this methodology may be an alternative way to produce targets of low enriched uranium (LEU) to fabricate radiopharmaceuticals, as 99 Mo, used for cancer diagnosis. To study the electrodeposition, a solution of 10 mM uranyl nitrate, in 2-propanol, containing uranium enriched to 2.4% in 235 U, with pH = 1, was prepared and measurements with an alpha spectrometer were performed. These studies are justified by the need to produce 99 Mo since, despite using molybdenum in bulk, Brazil is totally dependent on its import. In this project, we intend to obtain a process that may be technologically feasible to control the radiation targets for 99 Mo production. (authors)

  13. Evaluation of a measurement system for Uranium electrodeposition control to radiopharmaceuticals production

    Energy Technology Data Exchange (ETDEWEB)

    Tufic Madi Filho; Adonis Marcelo Saliba Silva; Jose Patricio Nahuel Cardenas; Maria da Conceicao Costa Pereira; Valdir Maciel Lopes; Alexandre, P. S.; Diogo, F. S.; Rafael, T. P.; Vitor, O. A; Anderson, F. L.; Lucas, R. S.; Brianna, S.; Eduardo, L. C. [Nuclear and Energy Research Institute, IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242 Cid Univers. CEP: 05508-000- Sao Paulo-SP, (Brazil)

    2015-07-01

    For 2016, studies by international bodies forecast a crisis in the supply of Molybdenum ({sup 99}Mo), which is the generator of {sup 99m}Tc, widely used for medical diagnoses and treatments. As a result, many countries are making efforts to prevent this crisis. Brazil is developing the Brazilian Multipurpose Reactor (RMB) project, under the responsibility of the National Nuclear Energy Commission (CNEN). The RMB is a nuclear reactor for research and production of radioisotopes used in the production of radiopharmaceuticals and radioactive sources, broadly used in industrial and research areas in Brazil. Electrodeposition of uranium is a common practice to create samples for alpha spectrometry and this methodology may be an alternative way to produce targets of low enriched uranium (LEU) to fabricate radiopharmaceuticals, as {sup 99}Mo, used for cancer diagnosis. To study the electrodeposition, a solution of 10 mM uranyl nitrate, in 2-propanol, containing uranium enriched to 2.4% in {sup 235}U, with pH = 1, was prepared and measurements with an alpha spectrometer were performed. These studies are justified by the need to produce {sup 99}Mo since, despite using molybdenum in bulk, Brazil is totally dependent on its import. In this project, we intend to obtain a process that may be technologically feasible to control the radiation targets for {sup 99}Mo production. (authors)

  14. Establishment of Passive Energy Conservation Measure and Economic Evaluation of Fenestration System in Nonresidential Building of Korea

    Directory of Open Access Journals (Sweden)

    Bo-Eun Choi

    2017-01-01

    Full Text Available ECO2 (building energy efficiency rating program and passive energy conservation measures (ECMs were established as a basic study for targeted methodologies and decision support systems development in Korea to meet national regulations. The primary energy consumption and economic evaluation of nonresidential buildings was performed. Passive ECMs were classified as planning and performance elements. The planning elements are the window-to-wall ratio (WWR and horizontal shading angle. The performance elements are the thermal transmittance (U-value of the walls, roof, and floor and the U-value and solar heat gain coefficient (SHGC of windows. This study focused on the window-to-wall ratio and the U-value and solar heat gain coefficient of windows. An economic efficiency database for the constructed alternatives was built; the target building was set and the Passive ECM List for the target building was derived. The energy consumption evaluation and economic evaluation were performed for each of the constructed alternatives, and a methodology for guiding energy efficiency decisions was proposed based on the performance evaluation results, and the optimal Passive ECM List for the target building was derived.

  15. Health System Measurement Project

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Health System Measurement Project tracks government data on critical U.S. health system indicators. The website presents national trend data as well as detailed...

  16. A system for tumor heterogeneity evaluation and diagnosis based on tumor markers measured routinely in the laboratory.

    Science.gov (United States)

    Hui, Liu; Rixv, Liu; Xiuying, Zhou

    2015-12-01

    To develop an efficient and reliable approach to estimate tumor heterogeneity and improve tumor diagnosis using multiple tumor markers measured routinely in the clinical laboratory. A total of 161 patients with different cancers were recruited as the cancer group, and 91 patients with non-oncological conditions were required as the non-oncological disease group. The control group comprised 90 randomly selected healthy subjects. AFP, CEA, CYFRA, CA125, CA153, CA199, CA724, and NSE levels were measured in all these subjects with a chemiluminescent microparticle immunoassay. The tumor marker with the maximum S/CO value (sample test value:cutoff value for discriminating individuals with and without tumors) was considered as a specific tumor marker (STM) for an individual. Tumor heterogeneity index (THI)=N/P (N: number of STMs; P: percentage of individuals with STMs in a certain tumor population) was used to quantify tumor heterogeneity: high THI indicated high tumor heterogeneity. The tumor marker index (TMI), TMI = STM×(number of positive tumor markers+1), was used for diagnosis. The THIs of lung, gastric, and liver cancers were 8.33, 9.63, and 5.2, respectively, while the ROC-areas under the curve for TMI were 0.862, 0.809, and 0.966. In this study, we developed a novel index for tumor heterogeneity based on the expression of various routinely evaluated serum tumor markers. Development of an evaluation system for tumor heterogeneity on the basis of this index could provide an effective diagnostic tool for some cancers. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Evaluating a Radar-Based, Non Contact Streamflow Measurement System in the San Joaquin River at Vernalis, California

    Science.gov (United States)

    Cheng, Ralph T.; Gartner, Jeffrey W.; Mason, Jr., Robert R.; Costa, John E.; Plant, William J.; Spicer, Kurt R.; Haeni, F. Peter; Melcher, Nick B.; Keller, William C.; Hayes, Ken

    2004-01-01

    Accurate measurement of flow in the San Joaquin River at Vernalis, California, is vital to a wide range of Federal and State agencies, environmental interests, and water contractors. The U.S. Geological Survey uses a conventional stage-discharge rating technique to determine flows at Vernalis. Since the flood of January 1997, the channel has scoured and filled as much as 20 feet in some sections near the measurement site resulting in an unstable stage-discharge rating. In response to recent advances in measurement techniques and the need for more accurate measurement methods, the Geological Survey has undertaken a technology demonstration project to develop and deploy a radar-based streamflow measuring system on the bank of the San Joaquin River at Vernalis, California. The proposed flow-measurement system consists of a ground-penetrating radar system for mapping channel geometries, a microwave radar system for measuring surface velocities, and other necessary infrastructure. Cross-section information derived from ground penetrating radar provided depths similar to those measured by other instruments during the study. Likewise, surface-velocity patterns and magnitudes measured by the pulsed Doppler radar system are consistent with near surface current measurements derived from acoustic velocity instruments. Since the ratio of surface velocity to mean velocity falls to within a small range of theoretical value, using surface velocity as an index velocity to compute river discharge is feasable. Ultimately, the non-contact radar system may be used to make continuous, near-real-time flow measurements during high and medium flows. This report documents the data collected between April 14, 2002 and May 17, 2002 for the purposes of testing this radar based system. Further analyses of the data collected during this field effort will lead to further development and improvement of the system.

  18. Radioisotope measurement system

    International Nuclear Information System (INIS)

    Villanueva Ruibal, Jose

    2007-01-01

    A radioisotope measurement system installed at L.M.R. (Ezeiza Atomic Center of CNEA) allows the measurement of nuclear activity from a wide range of radioisotopes. It permits to characterize a broad range of radioisotopes at several activity levels. The measurement hardware as well as the driving software have been developed and constructed at the Dept. of Instrumentation and Control. The work outlines the system's conformation and its operating concept, describes design characteristics, construction and the error treatment, comments assay results and supplies use advices. Measuring tests carried out employing different radionuclides confirmed the system performing satisfactorily and with friendly operation. (author) [es

  19. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Acharya, Viral V.; Heje Pedersen, Lasse; Philippon, Thomas

    2017-01-01

    We present an economic model of systemic risk in which undercapitalization of the financial sector as a whole is assumed to harm the real economy, leading to a systemic risk externality. Each financial institution’s contribution to systemic risk can be measured as its systemic expected shortfall...... of components of SES to predict emerging systemic risk during the financial crisis of 2007–2009....

  20. Quality assurance of automated emission measurement systems - long time evaluation; Kvalitetssaekring av automatiska emissionsmaetsystem - analys och laangtidsutvaerdering

    Energy Technology Data Exchange (ETDEWEB)

    Harnevie, Henrik; Andersson, Magnus [Swedpower, Stockholm (Sweden); Gustavsson, Lennart [Swedish National Testing and Research Inst., Boraas (Sweden)

    2004-11-01

    As a consequence of the waste incineration directive and the EG-directive of large combustion plant, standards to meet the requirements in those directives had been worked out within CEN. Among those standards a standard concerning 'quality assurance of automated measurement system' is of major importance (SS-EN 14181). All automated emission monitoring systems (AMS) used to verify the requirements in the EC combustion directives should follow the procedures in SS-EN 14181. The standard both handle different types of controls (as function controls and parallel measurements) and documentation of data and journals. To make it easier for their members to implement the standard this Vaermeforsk study had been realized. SEPA (Swedish Environmental Protection Agency) and Vattenfall have also financed the work. SEPAs interest of the standard is to receive information of which parts in the standard that are in conflict with their present legislation. The main objectives of this project had been to document and explain the separate parts in the standard (QAL2, QAL3 and AST). Especially how the standard affects the situation and the routines on the plants. Other objectives have been to identify differences between other Swedish legislation and explain the consequences of such differences. In this project the standard also has been used to evaluate an existing AMS for measurement of NO{sub x}, SO{sub 2} and dust. In most cases the analyzers succeed to fulfill the criteria mentioned in the standard. During QAL2 only the dust analyzer failed the controls. The results of the AST gave better results for the dust analyzer but the SO{sub 2}-analyzer failed the requirements. Differences and consequences of such differences between the standard and the current Swedish legislation are also described. Finally, the report gives recommendations to the plant owners how to handle the standard. The standard is already valid. However, the use of it will be regulated by the

  1. SACRI: A measure of situation awareness for use in the evaluation of nuclear power plant control room systems providing information about the current process state

    International Nuclear Information System (INIS)

    Hogg, D.N.; Follesoe, K.; Volden, F.S.; Torralba, B.

    1994-01-01

    Control room operator support systems and their interface designs have as one goal the enhancement of the operators' situation awareness of the dynamically changing process state. This paper describes a technique for measuring situation awareness within the Human Factors evaluation of control room operator-system interfaces. The technique, referred to as SACRI, has been evaluated in four simulator studies and the main findings from these studies are summarized in this paper. It is concluded that SACRI can be a useful supplement to operator performance measures currently existing for use within control room interface evaluations. (author). 16 refs, 2 figs, 3 tabs

  2. Pressure Measurement Systems

    Science.gov (United States)

    1990-01-01

    System 8400 is an advanced system for measurement of gas and liquid pressure, along with a variety of other parameters, including voltage, frequency and digital inputs. System 8400 offers exceptionally high speed data acquisition through parallel processing, and its modular design allows expansion from a relatively inexpensive entry level system by the addition of modular Input Units that can be installed or removed in minutes. Douglas Juanarena was on the team of engineers that developed a new technology known as ESP (electronically scanned pressure). The Langley ESP measurement system was based on miniature integrated circuit pressure-sensing transducers that communicated pressure information to a minicomputer. In 1977, Juanarena formed PSI to exploit the NASA technology. In 1978 he left Langley, obtained a NASA license for the technology, introduced the first commercial product, the 780B pressure measurement system. PSI developed a pressure scanner for automation of industrial processes. Now in its second design generation, the DPT-6400 is capable of making 2,000 measurements a second and has 64 channels by addition of slave units. New system 8400 represents PSI's bid to further exploit the 600 million U.S. industrial pressure measurement market. It is geared to provide a turnkey solution to physical measurement.

  3. Development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements

    Science.gov (United States)

    Rey, Charles A.

    1991-03-01

    The development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements are discussed. Efforts were directed towards the following task areas: design and development of a High Temperature Acoustic Levitator (HAL) for containerless processing and property measurements at high temperatures; testing of the HAL module to establish this technology for use as a positioning device for microgravity uses; construction and evaluation of a brassboard hot wall Acoustic Levitation Furnace; construction and evaluation of a noncontact temperature measurement (NCTM) system based on AGEMA thermal imaging camera; construction of a prototype Division of Amplitude Polarimetric Pyrometer for NCTM of levitated specimens; evaluation of and recommendations for techniques to control contamination in containerless materials processing chambers; and evaluation of techniques for heating specimens to high temperatures for containerless materials experimentation.

  4. Development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements

    Science.gov (United States)

    Rey, Charles A.

    1991-01-01

    The development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements are discussed. Efforts were directed towards the following task areas: design and development of a High Temperature Acoustic Levitator (HAL) for containerless processing and property measurements at high temperatures; testing of the HAL module to establish this technology for use as a positioning device for microgravity uses; construction and evaluation of a brassboard hot wall Acoustic Levitation Furnace; construction and evaluation of a noncontact temperature measurement (NCTM) system based on AGEMA thermal imaging camera; construction of a prototype Division of Amplitude Polarimetric Pyrometer for NCTM of levitated specimens; evaluation of and recommendations for techniques to control contamination in containerless materials processing chambers; and evaluation of techniques for heating specimens to high temperatures for containerless materials experimentation.

  5. Bioelectric Signal Measuring System

    Science.gov (United States)

    Guadarrama-Santana, A.; Pólo-Parada, L.; García-Valenzuela, A.

    2015-01-01

    We describe a low noise measuring system based on interdigitated electrodes for sensing bioelectrical signals. The system registers differential voltage measurements in order of microvolts. The base noise during measurements was in nanovolts and thus, the sensing signals presented a very good signal to noise ratio. An excitation voltage of 1Vrms with 10 KHz frequency was applied to an interdigitated capacitive sensor without a material under test and to a mirror device simultaneously. The output signals of both devices was then subtracted in order to obtain an initial reference value near cero volts and reduce parasitic capacitances due to the electronics, wiring and system hardware as well. The response of the measuring system was characterized by monitoring temporal bioelectrical signals in real time of biological materials such as embryo chicken heart cells and bovine suprarenal gland cells.

  6. Electrochemical thermodynamic measurement system

    Science.gov (United States)

    Reynier, Yvan [Meylan, FR; Yazami, Rachid [Los Angeles, CA; Fultz, Brent T [Pasadena, CA

    2009-09-29

    The present invention provides systems and methods for accurately characterizing thermodynamic and materials properties of electrodes and electrochemical energy storage and conversion systems. Systems and methods of the present invention are configured for simultaneously collecting a suite of measurements characterizing a plurality of interconnected electrochemical and thermodynamic parameters relating to the electrode reaction state of advancement, voltage and temperature. Enhanced sensitivity provided by the present methods and systems combined with measurement conditions that reflect thermodynamically stabilized electrode conditions allow very accurate measurement of thermodynamic parameters, including state functions such as the Gibbs free energy, enthalpy and entropy of electrode/electrochemical cell reactions, that enable prediction of important performance attributes of electrode materials and electrochemical systems, such as the energy, power density, current rate and the cycle life of an electrochemical cell.

  7. Application of Cherenkov light observation to reactor measurements (3). Evaluation of spent fuel elements of LWRs with Cherenkov light estimation system

    International Nuclear Information System (INIS)

    Yamamoto, Keiichi; Takeuchi, Tomoaki; Tsuchiya, Kunihiko; Hayashi, Takayasu; Kosuge, Fumiaki

    2016-11-01

    Development of the reactor measurement system has been carried out to obtain the real-time in-core nuclear and thermal information, where the quantitative measurement of brightness of Cherenkov light was investigated. The system would be applied as a monitoring system in severe accidents and for the advanced operation management technology in existing LWRs. This report summarized the modification of Cherenkov light estimation system described JAEA-Testing 2015-001 and the result of the burn-up evaluation by Cherenkov light image emitted from spent fuel elements of LWRs with the modified system. (author)

  8. Dialogue scanning measuring systems

    International Nuclear Information System (INIS)

    Borodyuk, V.P.; Shkundenkov, V.N.

    1985-01-01

    The main developments of scanning measuring systems intended for mass precision processsing of films in nuclear physics problems and in related fields are reviewed. A special attention is paid to the problem of creation of dialogue systems which permit to simlify the development of control computer software

  9. Evaluation of a lower-powered analyzer and sampling system for eddy-covariance measurements of nitrous oxide fluxes

    Science.gov (United States)

    Brown, Shannon E.; Sargent, Steve; Wagner-Riddle, Claudia

    2018-03-01

    Nitrous oxide (N2O) fluxes measured using the eddy-covariance method capture the spatial and temporal heterogeneity of N2O emissions. Most closed-path trace-gas analyzers for eddy-covariance measurements have large-volume, multi-pass absorption cells that necessitate high flow rates for ample frequency response, thus requiring high-power sample pumps. Other sampling system components, including rain caps, filters, dryers, and tubing, can also degrade system frequency response. This field trial tested the performance of a closed-path eddy-covariance system for N2O flux measurements with improvements to use less power while maintaining the frequency response. The new system consists of a thermoelectrically cooled tunable diode laser absorption spectrometer configured to measure both N2O and carbon dioxide (CO2). The system features a relatively small, single-pass sample cell (200 mL) that provides good frequency response with a lower-powered pump ( ˜ 250 W). A new filterless intake removes particulates from the sample air stream with no additional mixing volume that could degrade frequency response. A single-tube dryer removes water vapour from the sample to avoid the need for density or spectroscopic corrections, while maintaining frequency response. This eddy-covariance system was collocated with a previous tunable diode laser absorption spectrometer model to compare N2O and CO2 flux measurements for two full growing seasons (May 2015 to October 2016) in a fertilized cornfield in Southern Ontario, Canada. Both spectrometers were placed outdoors at the base of the sampling tower, demonstrating ruggedness for a range of environmental conditions (minimum to maximum daily temperature range: -26.1 to 31.6 °C). The new system rarely required maintenance. An in situ frequency-response test demonstrated that the cutoff frequency of the new system was better than the old system (3.5 Hz compared to 2.30 Hz) and similar to that of a closed-path CO2 eddy-covariance system (4

  10. Evaluation of the confusion matrix method in the validation of an automated system for measuring feeding behaviour of cattle.

    Science.gov (United States)

    Ruuska, Salla; Hämäläinen, Wilhelmiina; Kajava, Sari; Mughal, Mikaela; Matilainen, Pekka; Mononen, Jaakko

    2018-03-01

    The aim of the present study was to evaluate empirically confusion matrices in device validation. We compared the confusion matrix method to linear regression and error indices in the validation of a device measuring feeding behaviour of dairy cattle. In addition, we studied how to extract additional information on classification errors with confusion probabilities. The data consisted of 12 h behaviour measurements from five dairy cows; feeding and other behaviour were detected simultaneously with a device and from video recordings. The resulting 216 000 pairs of classifications were used to construct confusion matrices and calculate performance measures. In addition, hourly durations of each behaviour were calculated and the accuracy of measurements was evaluated with linear regression and error indices. All three validation methods agreed when the behaviour was detected very accurately or inaccurately. Otherwise, in the intermediate cases, the confusion matrix method and error indices produced relatively concordant results, but the linear regression method often disagreed with them. Our study supports the use of confusion matrix analysis in validation since it is robust to any data distribution and type of relationship, it makes a stringent evaluation of validity, and it offers extra information on the type and sources of errors. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Calorimetric measuring systems

    DEFF Research Database (Denmark)

    Ritchie, Andrew Ewen; Pedersen, John Kim; Blaabjerg, Frede

    2004-01-01

    in the system. If the switching speed can be increased, improvements may be possible (e.g., current ripple in an electrical machine or physical size of passive components may be reduced). On the other hand, increased switching speed may cause additional losses in a power electronic system and increase...... the system cooling requirement. A common problem is that high-frequency phenomena like proximity effect, skin effect, hysteresis losses, and eddy current losses appear in the systems. These losses are very difficult to treat both theoretically and in practice. It is often difficult to measure the effect...

  12. Measuring Student Growth within a Merit-Pay Evaluation System: Perceived Effects on Music Teacher Motivation Career Commitment

    Science.gov (United States)

    Munroe, Angela

    2017-01-01

    In this experimental study, music teachers from a large school district were randomly assigned to one of two hypothetical conditions reflecting different methods for measuring student growth under a merit pay compensation system. In Scenario A, half of a teacher's effectiveness rating was based on student standardized test scores in reading,…

  13. [Patient evaluation and outcome measures].

    Science.gov (United States)

    Nieto Pol, Enrique

    2014-01-01

    Both the initial evaluation and follow-up of patients with osteoarthritis require systematic evaluation of the indicators that provide information on the degree of involvement of the disease and allow its quantification. Reliable measures of disease progression help decision-making by clinicians and provide valid information on treatment response and the effectiveness of the distinct therapeutic interventions. The instruments recommended in research, as outcome measures in osteoarthritis, are pain evaluation, assessment of physical function, and self-reported global evaluation. In studies lasting more than 1 year, structural changes are evaluated through simple X-ray. Self-reported quality of life assessment and physician global assessment are also recommended as options. These indicators should be incorporated into routine clinical practice for adequate evaluation and correct follow-up of patients with osteoarthritis. The recommended pain evaluation method for use in clinical practice is the visual analog scale (VAS). The best instrument to evaluate physical function in patients with hip or knee osteoarthritis is the WOMAC scale (Western Ontario and McMaster Universities Osteoarthritis Index). For patient-reported global assessment in routine practice, the recommended scales are VAS or the SF-12 (12-item short-form health survey). Copyright © 2014 Elsevier España, S.L. All rights reserved.

  14. Evaluation of a lower-powered analyzer and sampling system for eddy-covariance measurements of nitrous oxide fluxes

    Directory of Open Access Journals (Sweden)

    S. E. Brown

    2018-03-01

    Full Text Available Nitrous oxide (N2O fluxes measured using the eddy-covariance method capture the spatial and temporal heterogeneity of N2O emissions. Most closed-path trace-gas analyzers for eddy-covariance measurements have large-volume, multi-pass absorption cells that necessitate high flow rates for ample frequency response, thus requiring high-power sample pumps. Other sampling system components, including rain caps, filters, dryers, and tubing, can also degrade system frequency response. This field trial tested the performance of a closed-path eddy-covariance system for N2O flux measurements with improvements to use less power while maintaining the frequency response. The new system consists of a thermoelectrically cooled tunable diode laser absorption spectrometer configured to measure both N2O and carbon dioxide (CO2. The system features a relatively small, single-pass sample cell (200 mL that provides good frequency response with a lower-powered pump ( ∼  250 W. A new filterless intake removes particulates from the sample air stream with no additional mixing volume that could degrade frequency response. A single-tube dryer removes water vapour from the sample to avoid the need for density or spectroscopic corrections, while maintaining frequency response. This eddy-covariance system was collocated with a previous tunable diode laser absorption spectrometer model to compare N2O and CO2 flux measurements for two full growing seasons (May 2015 to October 2016 in a fertilized cornfield in Southern Ontario, Canada. Both spectrometers were placed outdoors at the base of the sampling tower, demonstrating ruggedness for a range of environmental conditions (minimum to maximum daily temperature range: −26.1 to 31.6 °C. The new system rarely required maintenance. An in situ frequency-response test demonstrated that the cutoff frequency of the new system was better than the old system (3.5 Hz compared to 2.30 Hz and similar to that of a closed

  15. Design, construction and performance evaluation of the target tissue thickness measurement system in intraoperative radiotherapy for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yazdani, Mohammad Reza, E-mail: myazdani@aut.ac.ir [Faculty of Energy Engineering and Physics, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Setayeshi, Saeed, E-mail: setayesh@aut.ac.ir [Faculty of Energy Engineering and Physics, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Arabalibeik, Hossein, E-mail: arabalibeik@tums.ac.ir [Research Center for Biomedical Technology and Robotics (RCBTR), Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Akbari, Mohammad Esmaeil [Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2017-05-21

    Intraoperative electron radiation therapy (IOERT), which uses electron beams for irradiating the target directly during the surgery, has the advantage of delivering a homogeneous dose to a controlled layer of tissue. Since the dose falls off quickly below the target thickness, the underlying normal tissues are spared. In selecting the appropriate electron energy, the accuracy of the target tissue thickness measurement is critical. In contrast to other procedures applied in IOERT, the routine measurement method is considered to be completely traditional and approximate. In this work, a novel mechanism is proposed for measuring the target tissue thickness with an acceptable level of accuracy. An electronic system has been designed and manufactured with the capability of measuring the tissue thickness based on the recorded electron density under the target. The results indicated the possibility of thickness measurement with a maximum error of 2 mm for 91.35% of data. Aside from system limitation in estimating the thickness of 5 mm phantom, for 88.94% of data, maximum error is 1 mm.

  16. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Acharya, Viral V.; Heje Pedersen, Lasse; Philippon, Thomas

    We present a simple model of systemic risk and we show that each financial institution's contribution to systemic risk can be measured as its systemic expected shortfall (SES), i.e., its propensity to be undercapitalized when the system as a whole is undercapitalized. SES increases...... with the institution's leverage and with its expected loss in the tail of the system's loss distribution. Institutions internalize their externality if they are ‘taxed’ based on their SES. We demonstrate empirically the ability of SES to predict emerging risks during the financial crisis of 2007-2009, in particular......, (i) the outcome of stress tests performed by regulators; (ii) the decline in equity valuations of large financial firms in the crisis; and, (iii) the widening of their credit default swap spreads....

  17. Beta measurement evaluation and upgrade

    International Nuclear Information System (INIS)

    Swinth, K.L.; Rathbun, L.A.; Roberson, P.L.; Endres, G.W.R.

    1986-01-01

    This program focuses on the resolution of problems associated with the field measurement of the beta dose component at Department of Energy (DOE) facilities. The change in DOE programs, including increased efforts in improved waste management and decontamination and decommissioning (D and D) of facilities, coupled with beta measurement problems identified at Three Mile Island has increased the need to improve beta measurements. In FY 1982, work was initiated to provide a continuing effort to identify problems associated with beta dose assessment at DOE facilities. The problems identified resulted in the development of this program. The investigation includes (1) an assessment of measurement systems now in use, (2) development of improved calibration systems and procedures, (3) application of innovative beta dosimetry concepts, (4) investigation of new instruments or concepts for monitoring and spectroscopy, and (5) development of recommendations to assure an adequate beta measurement program within DOE facilities

  18. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Heje Pedersen, Lasse

    We present a simple model of systemic risk and we show that each financial institution’s contribution to systemic risk can be measured as its systemic expected shortfall (SES), i.e., its propensity to be undercapitalized when the system as a whole is undercapitalized. SES increases...... with the institution’s leverage and with its expected loss in the tail of the system’s loss distribution. Institutions internalize their externality if they are “taxed” based on their SES. We demonstrate empirically the ability of SES to predict emerging risks during the financial crisis of 2007-2009, in particular......, (i) the outcome of stress tests performed by regulators; (ii) the decline in equity valuations of large financial firms in the crisis; and, (iii) the widening of their credit default swap spreads....

  19. Design, Construction and Evaluation of an Interchangeable Digital System to Measure Slip and Ground Speed of Existing 2WD Tractors in Iran

    Directory of Open Access Journals (Sweden)

    M Khosravi

    2012-05-01

    Full Text Available The majority of existing tractors in Iran are not equipped with any tools to measure and display slip and ground speed. This is mainly due to the lack of national standards for measuring tools and instruments of tractors. In current research, an interchangeable system for two wheel drive tractors has been designed. Furthermore, it has been assessed after construction. To measure actual and theoretical ground speed, four rotary encoders for sensing the rotation of front and rear wheels have been utilized. Slip and ground speed were measured by means of software which has been developed in an ATmega16PU microprocessor. The measured slip and speed are digitally displayed on tractor dashboard. To evaluate the performance of the system, the measured values of ground speed and slip were compared with their calculated values obtained from conventional method. The Micro-controller has been programmed in such a way that the effect of front wheel sliding on slip is eliminated. In all evaluation conditions (in field and on asphalt, the maximum difference between system measurements for slip and speed and calculated slip and speed via conventional method was 2.4% and 0.2 km h-1, respectively. With slight alteration this system can be fitted on any kind of exiting two wheel drive tractors in the country.

  20. Standard practice for evaluating performance characteristics of ultrasonic Pulse-Echo testing instruments and systems without the use of electronic measurement instruments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice describes procedures for evaluating the following performance characteristics of ultrasonic pulse-echo examination instruments and systems: Horizontal Limit and Linearity; Vertical Limit and Linearity; Resolution - Entry Surface and Far Surface; Sensitivity and Noise; Accuracy of Calibrated Gain Controls. Evaluation of these characteristics is intended to be used for comparing instruments and systems or, by periodic repetition, for detecting long-term changes in the characteristics of a given instrument or system that may be indicative of impending failure, and which, if beyond certain limits, will require corrective maintenance. Instrument characteristics measured in accordance with this practice are expressed in terms that relate to their potential usefulness for ultrasonic testing. Instrument characteristics expressed in purely electronic terms may be measured as described in E1324. 1.2 Ultrasonic examination systems using pulsed-wave trains and A-scan presentation (rf or video) may be ev...

  1. Covariance evaluation system

    International Nuclear Information System (INIS)

    Kawano, Toshihiko; Shibata, Keiichi.

    1997-09-01

    A covariance evaluation system for the evaluated nuclear data library was established. The parameter estimation method and the least squares method with a spline function are used to generate the covariance data. Uncertainties of nuclear reaction model parameters are estimated from experimental data uncertainties, then the covariance of the evaluated cross sections is calculated by means of error propagation. Computer programs ELIESE-3, EGNASH4, ECIS, and CASTHY are used. Covariances of 238 U reaction cross sections were calculated with this system. (author)

  2. Ground-truth measurement systems

    Science.gov (United States)

    Serafin, R.; Seliga, T. A.; Lhermitte, R. M.; Nystuen, J. A.; Cherry, S.; Bringi, V. N.; Blackmer, R.; Heymsfield, G. M.

    1981-01-01

    Ground-truth measurements of precipitation and related weather events are an essential component of any satellite system designed for monitoring rainfall from space. Such measurements are required for testing, evaluation, and operations; they provide detailed information on the actual weather events, which can then be compared with satellite observations intended to provide both quantitative and qualitative information about them. Also, very comprehensive ground-truth observations should lead to a better understanding of precipitation fields and their relationships to satellite data. This process serves two very important functions: (a) aiding in the development and interpretation of schemes of analyzing satellite data, and (b) providing a continuing method for verifying satellite measurements.

  3. Enterprise performance measurement systems

    Directory of Open Access Journals (Sweden)

    Milija Bogavac

    2014-10-01

    Full Text Available Performance measurement systems are an extremely important part of the control and management actions, because in this way a company can determine its business potential, its market power, potential and current level of business efficiency. The significance of measurement consists in influencing the relationship between the results of reproduction (total volume of production, value of production, total revenue and profit and investments to achieve these results (factors of production spending and hiring capital in order to achieve the highest possible quality of the economy. (The relationship between the results of reproduction and investment to achieve them quantitatively determines economic success as the quality of the economy. Measuring performance allows the identification of the economic resources the company has, so looking at the key factors that affect its performance can help to determine the appropriate course of action.

  4. Radon integral measurement system

    International Nuclear Information System (INIS)

    Garcia H, J.M.

    1994-01-01

    The Radon Integral Measurement System (SMIR) is a device designed specially to detect, to count and to store the data of the acquisition of alpha particles emitted by Radon-222 coming from the underground. The system includes a detection chamber, a radiation detector, a digital system with bateries backup and an auxiliary photovoltaic cell. A personal computer fixes the mode in which the system works, transmitting the commands to the system by the serial port. The heart of the system is a microprocesor working with interrupts by hardware. Every external device to the microprocessor sends his own interrupt request and the microprocessor handles the interrupts with a defined priority. The system uses a real time clock, compatible with the microprocessor, to take care of the real timing and date of the acquisition. A non volatile RAM is used to store data of two bytes every 15 minutes along 41 days as a maximum. After the setting up to the system by the computer, it can operate in stand alone way for up 41 days in the working place without the lose of any data. If the memory is full the next data will be written in the first locations of the memory. The memory is divided in pages corresponding every one of this to a different day of the acquisition. The counting time for every acquisition can be programmed by the user from 15 minutes to 65535 minutes but it is recommended to use a small time not to reach the limit of 65535 counts in every acquisition period. We can take information of the system without affecting the acquisition process in the field by using a lap top computer, then the information can be stored in a file. There is a program in the computer that can show the information in a table of values or in a bar graph. (Author)

  5. Evaluating penetration-monitoring systems

    International Nuclear Information System (INIS)

    Markin, J.T.

    1981-01-01

    Evaluating the performance of a process monitoring system in detecting improper activities that could be related to material diversion requires a framework for addressing the complexity and statistical uncertainty of such systems. This report proposes a methodology that determines the optimal divertor strategy against a monitoring system and the system probability of detection. This method extends previous work by correctly modeling uncorrelated and correlated measurement errors for radiation monitors

  6. Fault Severity Evaluation and Improvement Design for Mechanical Systems Using the Fault Injection Technique and Gini Concordance Measure

    Directory of Open Access Journals (Sweden)

    Jianing Wu

    2014-01-01

    Full Text Available A new fault injection and Gini concordance based method has been developed for fault severity analysis for multibody mechanical systems concerning their dynamic properties. The fault tree analysis (FTA is employed to roughly identify the faults needed to be considered. According to constitution of the mechanical system, the dynamic properties can be achieved by solving the equations that include many types of faults which are injected by using the fault injection technique. Then, the Gini concordance is used to measure the correspondence between the performance with faults and under normal operation thereby providing useful hints of severity ranking in subsystems for reliability design. One numerical example and a series of experiments are provided to illustrate the application of the new method. The results indicate that the proposed method can accurately model the faults and receive the correct information of fault severity. Some strategies are also proposed for reliability improvement of the spacecraft solar array.

  7. Thyroid Uptake Measurement System

    International Nuclear Information System (INIS)

    Nguyen Duc Tuan; Nguyen Thi Bao My; Nguyen Van Sy

    2007-01-01

    The NED-UP.M7 is a complete thyroid uptake and analysis system specifically designed for nuclear medicine. Capable of performing a full range of studies this system provides fast, accurate results for Uptake Studies. The heart of the NED-UP.M7 is a microprocessor-controlled 2048 channel Compact Multi-Channel Analyzer, coupled to a 2 inch x 2 inch NaI(Tl) detector with a USB personal computer interface. The system offers simple, straight-forward operation using pre-programmed isotopes, and menudriven prompts to guide the user step by step through each procedure. The pre-programmed radionuclides include I-123, I-125, I-131, Tc-99m and Cs-137. The user-defined radionuclides also allow for isotope identification while the printer provides hard copy printouts for patient and department record keeping. The included software program running on PC (Windows XP-based) is a user friendly program with menudriven and graphic interface for easy controlling the system and managing measurement results of patient on Excel standard form. (author)

  8. Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter

    Directory of Open Access Journals (Sweden)

    Pakbin Payam

    2008-11-01

    Full Text Available Abstract Background A newly designed electrostatic precipitator (ESP in tandem with Versatile Aerosol Concentration Enrichment System (VACES was developed by the University of Southern California to collect ambient aerosols on substrates appropriate for chemical and toxicological analysis. The laboratory evaluation of this sampler is described in a previous paper. The main objective of this study was to evaluate the performance of the new VACES-ESP system in the field by comparing the chemical characteristics of the PM collected in the ESP to those of reference samplers operating in parallel. Results The field campaign was carried out in the period from August, 2007 to March, 2008 in a typical urban environment near downtown Los Angeles. Each sampling set was restricted to 2–3 hours to minimize possible sampling artifacts in the ESP. The results showed that particle penetration increases and ozone concentration decreases with increasing sampling flow rate, with highest particle penetration observed between 100 nm and 300 nm. A reference filter sampler was deployed in parallel to the ESP to collect concentration-enriched aerosols, and a MOUDI sampler was used to collect ambient aerosols. Chemical analysis results showed very good agreement between the ESP and MOUDI samplers in the concentrations of trace elements and inorganic ions. The overall organic compound content of PM collected by the ESP, including polycyclic aromatic hydrocarbons (PAHs, hopanes, steranes, and alkanes, was in good agreement with that of the reference sampler, with an average ESP -to -reference concentration ratio of 1.07 (± 0.38. While majority of organic compound ratios were close to 1, some of the semi-volatile organic species had slightly deviated ratios from 1, indicating the possibility of some sampling artifacts in the ESP due to reactions of PM with ozone and radicals generated from corona discharge, although positive and negative sampling artifacts in the

  9. Evaluating performance characteristics of x-ray equipment and film systems without the use of electronic measurement and/or special instruments

    International Nuclear Information System (INIS)

    Bianchi, M.F.; DeNitto, C.; Liscio, A.; Scala, N.

    2004-01-01

    Measurement and control of characteristics of NDT equipment and system that produce output to be interpreted by inspector is one of the most important tools for NDT reliability. Control activity should be based on: initial accurate measurement and calibration; periodical check to assure maintenance of calibration status; and, immediate verification and corrective action when any malfunctioning is suspected. 'Self-calibration' intended as capability of NDT facility to calibrate and control its own equipment and systems is very important for continuous and reliable activity. Typical approach based on this philosophy is ASTM E317 'Standard Practice for Evaluating Performance Characteristics of Ultrasonic Pulse-Echo Examination Instruments and Systems Without the Use of Electronic Measurement Instruments' that is applicable to shop or field conditions. Is 'Self-calibration' applicable to radiographic system too? Many characteristics can be self-determined according to existing practices and methods, but other ones require assistance and cooperation of supplier both for film system and x-ray equipment. A certified film system being controlled by pre-exposed filmstrips can be adopted as 'measurement device' for X-ray output concerning both intensity and contrast. Basically x-ray equipment manufacturer performs initial accurate measurement and calibration using electronic measurement and/or special instrumentation as necessary. Then specific film set on 'low-price' blocks and specimens is produced according to standard practice whose guidelines are supplied by this paper. Film set, blocks, specimens and results referred to specific film system will be the reference kit for periodical check in NDT facility. This paper supplies some guidelines for standard practice based on testing using mainly GE Inspection Technologies radiographic system being available in Avio facilities. (author)

  10. Evaluation of a novel noninvasive continuous core temperature measurement system with a zero heat flux sensor using a manikin of the human body.

    Science.gov (United States)

    Brandes, Ivo F; Perl, Thorsten; Bauer, Martin; Bräuer, Anselm

    2015-02-01

    Reliable continuous perioperative core temperature measurement is of major importance. The pulmonary artery catheter is currently the gold standard for measuring core temperature but is invasive and expensive. Using a manikin, we evaluated the new, noninvasive SpotOn™ temperature monitoring system (SOT). With a sensor placed on the lateral forehead, SOT uses zero heat flux technology to noninvasively measure core temperature; and because the forehead is devoid of thermoregulatory arteriovenous shunts, a piece of bone cement served as a model of the frontal bone in this study. Bias, limits of agreements, long-term measurement stability, and the lowest measurable temperature of the device were investigated. Bias and limits of agreement of the temperature data of two SOTs and of the thermistor placed on the manikin's surface were calculated. Measurements obtained from SOTs were similar to thermistor values. The bias and limits of agreement lay within a predefined clinically acceptable range. Repeat measurements differed only slightly, and stayed stable for hours. Because of its temperature range, the SOT cannot be used to monitor temperatures below 28°C. In conclusion, the new SOT could provide a reliable, less invasive and cheaper alternative for measuring perioperative core temperature in routine clinical practice. Further clinical trials are needed to evaluate these results.

  11. System tuning and measurement error detection testing

    International Nuclear Information System (INIS)

    Krejci, Petr; Machek, Jindrich

    2008-09-01

    The project includes the use of the PEANO (Process Evaluation and Analysis by Neural Operators) system to verify the monitoring of the status of dependent measurements with a view to early measurement fault detection and estimation of selected signal levels. At the present stage, the system's capabilities of detecting measurement errors was assessed and the quality of the estimates was evaluated for various system configurations and the formation of empiric models, and rules were sought for system training at chosen process data recording parameters and operating modes. The aim was to find a suitable system configuration and to document the quality of the tuned system on artificial failures

  12. Emittance measuring system on the UNILAC

    International Nuclear Information System (INIS)

    Ehrich, A.; Glatz, J.; Strahl, P.

    A description is given of one of the beam emittance measuring systems designed for the UNILAC at GSI. The measuring system mechanics and the detector system are detailed, and the associated electronics are discussed. Computer programming and data processing and evaluation are described

  13. Stresses and residual stresses optical measurements systems evaluation; Avaliacao de sistemas opticos de medicao de tensoes e tensoes residuais em dutos

    Energy Technology Data Exchange (ETDEWEB)

    Peixoto Filho, Flavio Tito; Goncalves Junior, Armando Albertazzi [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil). Lab. de Metrologia e Automatizacao (LABMETRO)

    2004-07-01

    There is always a constant concern about the pipelines' integrity. An important control parameter is the level of total mechanical stresses acting over the pipeline. However, the loading and residual stresses acting on a pipeline are not measured in the field as much as necessary. Technical difficulties and the high cost of the nowadays techniques and the hostile measurement conditions are the main reason for that. An alternative method has been developed at the Universidade Federal de Santa Catarina (UFSC) since 1992. A new optical measurement device is used to measure strains, mechanical stresses and residual stresses acting over the structure. A metrological and functional evaluation of this system is the main focus of this paper. (author)

  14. Evaluation of the level of skill required of operators of a computer-assisted radiologic total lung capacity measurement system

    International Nuclear Information System (INIS)

    Mazzeo, J.

    1985-01-01

    This research was conducted to obtain information regarding the feasibility of using non-medical personnel to obtain measurements of radiologic total lung capacity (TLC). Operators from each of four groups (general undergraduates, nursing students, medical students, radiologists) differing in the amount of medical training and/or experience reading x-rays, performed each of two tasks. The first task was the measurement of radiologic TLC for a set of twenty x-rays. The second task consisted of tracing the outline of the anatomical structures that must be identified in the execution of the radiologic TLC measurement task. Data from the radiologic TLC measurement task were used to identify possible group differences in the reliability and validity of the measures. The reliability analyses were performed within the framework of Generalizability Theory. While the results are not conclusive, due to small sizes, the analyses suggest that group differences in reliability of the measures, if they exist, are small

  15. Evaluation of EIT system performance.

    Science.gov (United States)

    Yasin, Mamatjan; Böhm, Stephan; Gaggero, Pascal O; Adler, Andy

    2011-07-01

    An electrical impedance tomography (EIT) system images internal conductivity from surface electrical stimulation and measurement. Such systems necessarily comprise multiple design choices from cables and hardware design to calibration and image reconstruction. In order to compare EIT systems and study the consequences of changes in system performance, this paper describes a systematic approach to evaluate the performance of the EIT systems. The system to be tested is connected to a saline phantom in which calibrated contrasting test objects are systematically positioned using a position controller. A set of evaluation parameters are proposed which characterize (i) data and image noise, (ii) data accuracy, (iii) detectability of single contrasts and distinguishability of multiple contrasts, and (iv) accuracy of reconstructed image (amplitude, resolution, position and ringing). Using this approach, we evaluate three different EIT systems and illustrate the use of these tools to evaluate and compare performance. In order to facilitate the use of this approach, all details of the phantom, test objects and position controller design are made publicly available including the source code of the evaluation and reporting software.

  16. Nuclear data evaluation method and evaluation system

    International Nuclear Information System (INIS)

    Liu Tingjin

    1995-01-01

    The evaluation methods and Nuclear Data Evaluation System have been developed in China. A new version of the system has been established on Micro-VAX2 computer, which is supported by IAEA under the technology assistance program. The flow chart of Chinese Nuclear Data Evaluation System is shown out. For last ten years, the main efforts have been put on the double differential cross section, covariance data and evaluated data library validation. The developed evaluation method and Chinese Nuclear Data Evaluation System have been widely used at CNDC and in Chinese Nuclear Data Network for CENDL. (1 tab., 15 figs.)

  17. MODULAR CONSTRUCTION SYSTEM EVALUATION

    International Nuclear Information System (INIS)

    Gillespie, S.

    2002-01-01

    The purpose of this study is to respond to U.S. Department of Energy (DOE) Technical Direction Letter (TDL) 02-003 (Waisley 2001), which directs Bechtel SAIC Company, LLC (BSC) to complete a design study to recommend repository design options to support receipt and/or emplacement of any or all of the following: commercial spent nuclear fuel (CSNF), high-level radioactive waste (HLW), DOE-managed spent nuclear fuel (DSNF) (including naval spent nuclear fuel [SNF]), and immobilized plutonium (if available), as soon as practicable, but no later than 2010. From the possible design options, a recommended approach will be determined for further evaluation to support the preliminary design of the repository. This study integrates the results of the repository Design Evolution Study (Rowe 2002) with supporting studies concerning national transportation options (BSC 2002b) and Nevada transportation options (Gehner 2002). The repository Design Evolution Study documents the processes used to reevaluate the design, construction, operation, and cost of the repository in response to TDL 02-003 (Waisley 2001), and to determine possible repository conceptual design options. The transportation studies evaluate the national and Nevada transportation options that support the repository conceptual design options. An evaluation methodology was established, based on Program-level requirements developed for the study in reference BSC 2001a, to allow the repository and system design options to be evaluated on a consistent basis. The transportation options and the design components were integrated into system design implementation options, which were evaluated using receipt and emplacement scenarios. The scenarios tested the ability of the design concept to adapt to changes in funding, waste receipt rate, and Nevada rail transportation availability. The results of the evaluation (in terms of system throughput, cost, and schedule) were then compared to the Program-level requirements, and

  18. Process evaluation distributed system

    Science.gov (United States)

    Moffatt, Christopher L. (Inventor)

    2006-01-01

    The distributed system includes a database server, an administration module, a process evaluation module, and a data display module. The administration module is in communication with the database server for providing observation criteria information to the database server. The process evaluation module is in communication with the database server for obtaining the observation criteria information from the database server and collecting process data based on the observation criteria information. The process evaluation module utilizes a personal digital assistant (PDA). A data display module in communication with the database server, including a website for viewing collected process data in a desired metrics form, the data display module also for providing desired editing and modification of the collected process data. The connectivity established by the database server to the administration module, the process evaluation module, and the data display module, minimizes the requirement for manual input of the collected process data.

  19. Measurement and evaluation of sustainable development

    International Nuclear Information System (INIS)

    Kondyli, Julia

    2010-01-01

    This paper develops a methodology to analyse, measure and evaluate sustainable development (SD). A holistic approach (systems analysis) is applied to operationalise the SD concept and an integrated approach (composite indicator construction) is adopted for the measurement of SD. The operationalisation of the SD concept is based on an in-depth systems analysis of issues associated with economic, social and environmental problems in a policy context. The composite indicator (overall sustainability index) is developed based on the three composite sub-indicators of the SD dimensions. The valuation of the SD is based both on the aggregated sub-indicators and the overall composite indicator. The methodology is used to evaluate the SD of the North Aegean islands between different temporal points. The assessment of the change in the islands' SD is based on a quartile grading scale of the overall SD composite scores.

  20. Evaluation of load case ''switch-off of the high pressure pump of the emergency core cooling system'', measures of verification and in situ-test

    International Nuclear Information System (INIS)

    Trobitz, M.; Mattheis, A.; Kerkhof, K.; Hippelein, K.; Hofstoetter, P.

    1998-01-01

    Within the framework of periodic safety inspection of the Gundremmingen power station (RWE-Bayernwerk - KRB II), the load collectives used for the design of safety-relevant systems and components were checked for their consistency with latest updates of the design basis. It was found that there was no analytical information or study available describing a particular process and its effects, namely switch-off of the high-pressure feedwater pump of the emergency core cooling system. The paper reports the work performed for closing the gap, including preparatory analyses, accompanying measures such as vibration measurements during plant shut-down, as well as the preparation and performance of the in-situ test. The experimental results and the comparative evaluation of calculated and experimental data are presented. (orig./CB) [de

  1. Promoting Student Teachers' Content Related Knowledge in Teaching Systems Thinking: Measuring Effects of an Intervention through Evaluating a Videotaped Lesson

    Science.gov (United States)

    Rosenkränzer, Frank; Kramer, Tim; Hörsch, Christian; Schuler, Stephan; Rieß, Werner

    2016-01-01

    The understanding of complex, dynamic and animate systems has a special standing in education for sustainable development and biology. Thus one important role of science teacher education is to promote student teachers' Content Related Knowledge (CRK) for teaching systems thinking, consisting of extensive Content Knowledge (CK) and well formed…

  2. MARBLE (Multiple Antenna Radio-interferometry for Baseline Length Evaluation): Development of a Compact VLBI System for Calibrating GNSS and Electronic Distance Measurement Devices

    Science.gov (United States)

    Ichikawa, R.; Ishii, A.; Takiguchi, H.; Kimura, M.; Sekido, M.; Takefuji, K.; Ujihara, H.; Hanado, Y.; Koyama, Y.; Kondo, T.; Kurihara, S.; Kokado, K.; Kawabata, R.; Nozawa, K.; Mukai, Y.; Kuroda, J.; Ishihara, M.; Matsuzaka, S.

    2012-12-01

    We are developing a compact VLBI system with a 1.6-m diameter aperture dish in order to provide reference baseline lengths for calibration. The reference baselines are used to validate surveying instruments such as GPS and EDM and is maintained by the Geospatial Information Authority of Japan (GSI). The compact VLBI system will be installed at both ends of the reference baseline. Since the system is not sensitive enough to detect fringes between the two small dishes, we have designed a new observation concept including one large dish station. We can detect two group delays between each compact VLBI system and the large dish station based on conventional VLBI measurement. A group delay between the two compact dishes can be indirectly calculated using a simple equation. We named the idea "Multiple Antenna Radio-interferometry for Baseline Length Evaluation", or MARBLE system. The compact VLBI system is easy transportable and consists of the compact dish, a new wide-band front-end system, azimuth and elevation drive units, an IF down-converter unit, an antenna control unit (ACU), a counterweight, and a monument pillar. Each drive unit is equipped with a zero-backlash harmonic drive gearing component. A monument pillar is designed to mount typical geodetic GNSS antennas easily and an offset between the GNSS antenna reference point. The location of the azimuth-elevation crossing point of the VLBI system is precisely determined with an uncertainty of less than 0.2 mm. We have carried out seven geodetic VLBI experiments on the Kashima-Tsukuba baseline (about 54 km) using the two prototypes of the compact VLBI system between December 2009 and December 2010. The average baseline length and repeatability of the experiments is 54184874.0 ± 2.4 mm. The results are well consistent with those obtained by GPS measurements. In addition, we are now planning to use the compact VLBI system for precise time and frequency comparison between separated locations.

  3. Evaluation of corn genotypes for drought and heat stress tolerance using physiological measurements and a microcontroller-based monitoring system

    Science.gov (United States)

    Moisture deficit accompanied by high temperature are major abiotic stress factors that affect corn production in the southern United States, particularly during the reproductive stage of the plant. In evaluating plants for environmental stress tolerance, it is important to monitor changes in their ...

  4. Development of a Time-Intensity Evaluation System for Consumers: Measuring Bitterness and Retronasal Aroma of Coffee Beverages in 106 Untrained Panelists.

    Science.gov (United States)

    Gotow, Naomi; Moritani, Ami; Hayakawa, Yoshinobu; Akutagawa, Akihito; Hashimoto, Hiroshi; Kobayakawa, Tatsu

    2015-06-01

    In order to develop products that are acceptable to consumers, it is necessary to incorporate consumers' intentions into products' characteristics. Therefore, investigation of consumers' perceptions of the taste or smell of common beverages provides information that should be useful in predicting market responses. In this study, we sought to develop a time-intensity evaluation system for consumer panels. Using our system, we performed time-intensity evaluation of flavor attributes (bitterness and retronasal aroma) that consumers perceived after swallowing a coffee beverage. Additionally, we developed quantitative evaluation methods for determining whether consumer panelists can properly perform time-intensity evaluation. In every trial, we fitted an exponential function to measured intensity data for bitterness and retronasal aroma. The correlation coefficients between measured time-intensity data and the fitted exponential curves were greater than 0.8 in about 90% of trials, indicating that we had successfully developed a time-intensity system for use with consumer panelists, even after just a single training trial using a nontrained consumer. We classified participants into two groups based on their consumption of canned coffee beverages. Significant difference was observed in only AUC of sensory modality (bitterness compared with retronasal aroma) among conventional TI parameters using two-way ANOVA. However, three-way ANOVA including a time course revealed significant difference between bitterness and retronasal aroma in the high-consumption group. Moreover, the high-consumption group more easily discriminated between bitterness and retronasal aroma than the low-consumption group. This finding implied that manufacturers should select consumer panelists who are suitable for their concepts of new products. © 2015 Institute of Food Technologists®

  5. Measuring and evaluating the soft energy efficiency measures. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Suvilehto, H.-M.; Solid, D. [AaF-Industry Ltd, Solna (Sweden); Rouhiainen, V. [Adato Energia Ltd, Helsinki (Finland); Honkasalo, N.; Sarvaranta, A. [AaF-Consult Ltd, Solna (Sweden)

    2012-07-15

    ;soft' measures that aim to achieve behavioural change have not so far been covered by these methods. The recent year's research from Great Britain and Ireland has managed to identify statistically significant results from measures very similar for those carried out by the Finnish energy utilities. In this study, a number of domestic and international empirical studies and evaluations have been assessed, reviewed and used as a basis for suggesting a way to quantify the energy savings that are obtained with the 'soft' measures in Finland. The chosen method to evaluate the impacts of 'soft' measures is based on the available national data, the literature study and the general information available today on the proposed EU Directive on Energy Efficiency. According to our findings, reliable numeric data of the energy saving effects of the 'soft' measures on energy demand in Finland does not exist. Therefore, the evaluation based on saving percentages established in international studies is suggested to be regarded as a first step towards when developing system.

  6. Human Performance Evaluation System

    International Nuclear Information System (INIS)

    Hardwick, R.J. Jr.

    1985-01-01

    Operating nuclear power plants requires high standards of performance, extensive training and responsive management. Despite our best efforts inappropriate human actions do occur, but they can be managed. An extensive review of License Event Reports (LERs) was conducted which indicated continual inadequacy in human performance and in evaluation of root causes. Of some 31,000 LERs, about 5,000 or 16% were directly attributable to inappropriate actions. A recent analysis of 87 Significant Event Reports (issued by INPO in 1983) identified inappropriate actions as being the most frequent root cause (44% of the total). A more recent analysis of SERs issued in 1983 and 1984 indicate that 52% of the root causes were attributed to human performance. The Human Performance Evaluation System (HPES) is a comprehensive, coordinated utility/industry system for evaluating and reporting human performance situtations. HPES is a result of the realization that current reporting system provide limited treatment of human performance and rarely provide adequate information about root causes of inappropriate actions by individuals. The HPES was implemented to identify and eliminate root causes of inappropriate actions

  7. The evaluation and use of a portable TEPC system for measuring in-flight exposure to cosmic radiation

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, G.C.; Bentley, R.D.; Conroy, T.J.; Hunter, R.; Jones, J.B.L.; Pond, A.; Thomas, D.J

    2002-07-01

    A recent EC directive has called for all member states to introduce legislation covering the assessment and restriction of air crew exposure to cosmic radiation. In the UK the Civil Aviation Authority, in conjunction with the Department of the Environment, Transport and the Regions issued guidelines suggesting the use of a predictive code such as CARI for this purpose. In order to validate the use of calculated route doses, an extensive programme of measurements is being carried out in conjunction with Virgin Atlantic Airways, using a prototype HAWK TEPC developed by Far West Technology. This programme began in January 2000 and by the end of February 2001 had resulted in the accumulation of data from 74 flights. In this paper the instrument design is discussed, together with the calibration program. An overview of the in-flight results is also presented, including comparisons between measurements and calculations, which indicates that CARI under-predicts the route doses by approximately 20%. (author)

  8. The evaluation and use of a portable TEPC system for measuring in-flight exposure to cosmic radiation

    International Nuclear Information System (INIS)

    Taylor, G.C.; Bentley, R.D.; Conroy, T.J.; Hunter, R.; Jones, J.B.L.; Pond, A.; Thomas, D.J.

    2002-01-01

    A recent EC directive has called for all member states to introduce legislation covering the assessment and restriction of air crew exposure to cosmic radiation. In the UK the Civil Aviation Authority, in conjunction with the Department of the Environment, Transport and the Regions issued guidelines suggesting the use of a predictive code such as CARI for this purpose. In order to validate the use of calculated route doses, an extensive programme of measurements is being carried out in conjunction with Virgin Atlantic Airways, using a prototype HAWK TEPC developed by Far West Technology. This programme began in January 2000 and by the end of February 2001 had resulted in the accumulation of data from 74 flights. In this paper the instrument design is discussed, together with the calibration program. An overview of the in-flight results is also presented, including comparisons between measurements and calculations, which indicates that CARI under-predicts the route doses by approximately 20%. (author)

  9. Fibrinogen measurements in plasma and whole blood: a performance evaluation study of the dry-hematology system.

    Science.gov (United States)

    Ogawa, Satoru; Tanaka, Kenichi A; Nakajima, Yasufumi; Nakayama, Yoshinobu; Takeshita, Jun; Arai, Masatoshi; Mizobe, Toshiki

    2015-01-01

    An accurate and rapid determination of fibrinogen level is important during hemorrhage to establish a timely hemostatic intervention. The accuracy of fibrinogen measurements may be affected by the specific methodology for its determination, fluid therapies, and anticoagulant agents. The dry-hematology method (DRIHEMATO®) is a novel approach to determine fibrinogen levels in plasma and whole blood based on thrombin-activated coagulation time. We hypothesized that plasma or whole blood fibrinogen level using the dry-hematology method would be similar to those measured with conventional plasma fibrinogen assays. Acquired hypofibrinogenemia was modeled by serial dilutions of blood samples obtained from 12 healthy volunteers. Citrated whole blood samples were diluted with either normal saline, 5% human albumin, or 6% hydroxyethyl starch to achieve 25%, 50%, and 75% volume replacement. The dry-hematology method, the Clauss method, the prothrombin time (PT)-derived method, determination of antigen levels, and thromboelastometric fibrin formation were compared in plasma or whole blood samples. The effect of heparin on each assay was examined (0 to 6 IU/mL). Comparisons of dry-hematology and other methods were also conducted using ex vivo samples obtained from cardiac surgical patients (n = 60). In plasma samples, there were no significant differences between dry-hematology and the Clauss method, while dry-hematology showed lower fibrinogen levels compared with PT-derived and antigen level methods. The dry-hematology method yielded acceptable concordance correlation coefficients (Pc) with the Clauss method, the PT-derived method, and fibrinogen antigen levels (Pc = 0.91-0.99). The type of diluents and heparin affected the results of the PT-derived method and thromboelastometric assay, but not the dry-hematology method. In cardiac surgical patients, the overall correlation in fibrinogen levels between dry-hematology and the other methods was comparable to the results from

  10. Measuring and Analyzing the Scholarly Impact of Experimental Evaluation Initiatives

    DEFF Research Database (Denmark)

    Angelini, Marco; Ferro, Nicola; Larsen, Birger

    2014-01-01

    Evaluation initiatives have been widely credited with contributing highly to the development and advancement of information access systems, by providing a sustainable platform for conducting the very demanding activity of comparable experimental evaluation in a large scale. Measuring the impact...

  11. Systems Measures of Water Distribution System Resilience

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Katherine A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Murray, Regan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Walker, La Tonya Nicole [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Resilience is a concept that is being used increasingly to refer to the capacity of infrastructure systems to be prepared for and able to respond effectively and rapidly to hazardous events. In Section 2 of this report, drinking water hazards, resilience literature, and available resilience tools are presented. Broader definitions, attributes and methods for measuring resilience are presented in Section 3. In Section 4, quantitative systems performance measures for water distribution systems are presented. Finally, in Section 5, the performance measures and their relevance to measuring the resilience of water systems to hazards is discussed along with needed improvements to water distribution system modeling tools.

  12. Measuring name system health

    NARCIS (Netherlands)

    Casalicchio, Emiliano; Caselli, Marco; Coletta, Alessio; Di Blasi, Salvatore; Fovino, Igor Nai; Butts, Jonathan; Shenoi, Sujeet

    2012-01-01

    Modern critical infrastructure assets are exposed to security threats arising from their use of IP networks and the Domain Name System (DNS). This paper focuses on the health of DNS. Indeed, due to the increased reliance on the Internet, the degradation of DNS could have significant consequences for

  13. Optical absorption measurement system

    International Nuclear Information System (INIS)

    Draggoo, V.G.; Morton, R.G.; Sawicki, R.H.; Bissinger, H.D.

    1989-01-01

    This patent describes a non-intrusive method for measuring the temperature rise of optical elements under high laser power optical loading to determine the absorption coefficient. The method comprises irradiating the optical element with a high average power laser beam, viewing the optical element with an infrared camera to determine the temperature across the optical element and calculating the absorption of the optical element from the temperature

  14. Evaluation of Real-time Measurement Liver Tumor's Movement and SynchronyTM System's Accuracy of Radiosurgery using a Robot CyberKnife

    International Nuclear Information System (INIS)

    Kim, Gha Jung; Shim, Su Jung; Kim, Jeong Ho; Min, Chul Kee; Chung, Weon Kuu

    2008-01-01

    This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system (SynchronyTM). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and 13.9±5.5 mm, respectively from the superior to the inferior direction, 3.9 mm and 1.9±0.9 mm, respectively from left to right, and 8.3 mm and 4.9±1.9 mm, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be 3.3o and 2.6±1.3o, respectively for X (Left-Right) axis rotation, 4.8o and 2.3±1.0o, respectively for Y (Cranio-Caudal) axis rotation, 3.9o and 2.8±1.1o, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was 1.1±0.7 mm. Conclusion

  15. Simultaneous state-parameter estimation supports the evaluation of data assimilation performance and measurement design for soil-water-atmosphere-plant system

    Science.gov (United States)

    Hu, Shun; Shi, Liangsheng; Zha, Yuanyuan; Williams, Mathew; Lin, Lin

    2017-12-01

    Improvements to agricultural water and crop managements require detailed information on crop and soil states, and their evolution. Data assimilation provides an attractive way of obtaining these information by integrating measurements with model in a sequential manner. However, data assimilation for soil-water-atmosphere-plant (SWAP) system is still lack of comprehensive exploration due to a large number of variables and parameters in the system. In this study, simultaneous state-parameter estimation using ensemble Kalman filter (EnKF) was employed to evaluate the data assimilation performance and provide advice on measurement design for SWAP system. The results demonstrated that a proper selection of state vector is critical to effective data assimilation. Especially, updating the development stage was able to avoid the negative effect of ;phenological shift;, which was caused by the contrasted phenological stage in different ensemble members. Simultaneous state-parameter estimation (SSPE) assimilation strategy outperformed updating-state-only (USO) assimilation strategy because of its ability to alleviate the inconsistency between model variables and parameters. However, the performance of SSPE assimilation strategy could deteriorate with an increasing number of uncertain parameters as a result of soil stratification and limited knowledge on crop parameters. In addition to the most easily available surface soil moisture (SSM) and leaf area index (LAI) measurements, deep soil moisture, grain yield or other auxiliary data were required to provide sufficient constraints on parameter estimation and to assure the data assimilation performance. This study provides an insight into the response of soil moisture and grain yield to data assimilation in SWAP system and is helpful for soil moisture movement and crop growth modeling and measurement design in practice.

  16. Evaluation of non-invasive multispectral imaging as a tool for measuring the effect of systemic therapy in Kaposi sarcoma.

    Directory of Open Access Journals (Sweden)

    Jana M Kainerstorfer

    Full Text Available Diffuse multi-spectral imaging has been evaluated as a potential non-invasive marker of tumor response. Multi-spectral images of Kaposi sarcoma skin lesions were taken over the course of treatment, and blood volume and oxygenation concentration maps were obtained through principal component analysis (PCA of the data. These images were compared with clinical and pathological responses determined by conventional means. We demonstrate that cutaneous lesions have increased blood volume concentration and that changes in this parameter are a reliable indicator of treatment efficacy, differentiating responders and non-responders. Blood volume decreased by at least 20% in all lesions that responded by clinical criteria and increased in the two lesions that did not respond clinically. Responses as assessed by multi-spectral imaging also generally correlated with overall patient clinical response assessment, were often detectable earlier in the course of therapy, and are less subject to observer variability than conventional clinical assessment. Tissue oxygenation was more variable, with lesions often showing decreased oxygenation in the center surrounded by a zone of increased oxygenation. This technique could potentially be a clinically useful supplement to existing response assessment in KS, providing an early, quantitative, and non-invasive marker of treatment effect.

  17. Microbial ecology measurement system

    Science.gov (United States)

    1972-01-01

    The sensitivity and potential rapidity of the PIA test that was demonstrated during the feasibility study warranted continuing the effort to examine the possibility of adapting this test to an automated procedure that could be used during manned missions. The effort during this program has optimized the test conditions for two important respiratory pathogens, influenza virus and Mycoplasma pneumoniae, developed a laboratory model automated detection system, and investigated a group antigen concept for virus detection. Preliminary tests on the handling of oropharygeal clinical samples for PIA testing were performed using the adenovirus system. The results obtained indicated that the PIA signal is reduced in positive samples and is increased in negative samples. Treatment with cysteine appeared to reduce nonspecific agglutination in negative samples but did not maintain the signal in positive samples.

  18. The Evaluation of Computer Systems

    Directory of Open Access Journals (Sweden)

    Cezar Octavian Mihalcescu

    2007-01-01

    Full Text Available Generally, the evaluation of the computersystems is especially interesting at present from severalpoints of view: computer-related, managerial,sociological etc. The reasons for this extended interest arerepresented by the fact that IT becomes increasinglyimportant for reaching the goals of an organization, ingeneral, and the strategic ones in particular. Evaluationmeans the estimation or determination of value, and issynonymous with measuring the value. Evaluating theeconomic value of Computer Systems should be studiedat three levels: individually, at a group level and at anorganization level.

  19. Safety significance evaluation system

    International Nuclear Information System (INIS)

    Lew, B.S.; Yee, D.; Brewer, W.K.; Quattro, P.J.; Kirby, K.D.

    1991-01-01

    This paper reports that the Pacific Gas and Electric Company (PG and E), in cooperation with ABZ, Incorporated and Science Applications International Corporation (SAIC), investigated the use of artificial intelligence-based programming techniques to assist utility personnel in regulatory compliance problems. The result of this investigation is that artificial intelligence-based programming techniques can successfully be applied to this problem. To demonstrate this, a general methodology was developed and several prototype systems based on this methodology were developed. The prototypes address U.S. Nuclear Regulatory Commission (NRC) event reportability requirements, technical specification compliance based on plant equipment status, and quality assurance assistance. This collection of prototype modules is named the safety significance evaluation system

  20. Evaluation of geomagnetic field models using magnetometer measurements for satellite attitude determination system at low earth orbits: Case studies

    Science.gov (United States)

    Cilden-Guler, Demet; Kaymaz, Zerefsan; Hajiyev, Chingiz

    2018-01-01

    In this study, different geomagnetic field models are compared in order to study the errors resulting from the representation of magnetic fields that affect the satellite attitude system. For this purpose, we used magnetometer data from two Low Earth Orbit (LEO) spacecraft and the geomagnetic models IGRF-12 (Thébault et al., 2015) and T89 (Tsyganenko, 1989) models to study the differences between the magnetic field components, strength and the angle between the predicted and observed vector magnetic fields. The comparisons were made during geomagnetically active and quiet days to see the effects of the geomagnetic storms and sub-storms on the predicted and observed magnetic fields and angles. The angles, in turn, are used to estimate the spacecraft attitude and hence, the differences between model and observations as well as between two models become important to determine and reduce the errors associated with the models under different space environment conditions. We show that the models differ from the observations even during the geomagnetically quiet times but the associated errors during the geomagnetically active times increase. We find that the T89 model gives closer predictions to the observations, especially during active times and the errors are smaller compared to the IGRF-12 model. The magnitude of the error in the angle under both environmental conditions was found to be less than 1°. For the first time, the geomagnetic models were used to address the effects of the near Earth space environment on the satellite attitude.

  1. Mobility Models for Systems Evaluation

    Science.gov (United States)

    Musolesi, Mirco; Mascolo, Cecilia

    Mobility models are used to simulate and evaluate the performance of mobile wireless systems and the algorithms and protocols at the basis of them. The definition of realistic mobility models is one of the most critical and, at the same time, difficult aspects of the simulation of applications and systems designed for mobile environments. There are essentially two possible types of mobility patterns that can be used to evaluate mobile network protocols and algorithms by means of simulations: traces and synthetic models [130]. Traces are obtained by means of measurements of deployed systems and usually consist of logs of connectivity or location information, whereas synthetic models are mathematical models, such as sets of equations, which try to capture the movement of the devices.

  2. Bluetooth-based distributed measurement system

    International Nuclear Information System (INIS)

    Tang Baoping; Chen Zhuo; Wei Yuguo; Qin Xiaofeng

    2007-01-01

    A novel distributed wireless measurement system, which is consisted of a base station, wireless intelligent sensors and relay nodes etc, is established by combining of Bluetooth-based wireless transmission, virtual instrument, intelligent sensor, and network. The intelligent sensors mounted on the equipments to be measured acquire various parameters and the Bluetooth relay nodes get the acquired data modulated and sent to the base station, where data analysis and processing are done so that the operational condition of the equipment can be evaluated. The establishment of the distributed measurement system is discussed with a measurement flow chart for the distributed measurement system based on Bluetooth technology, and the advantages and disadvantages of the system are analyzed at the end of the paper and the measurement system has successfully been used in Daqing oilfield, China for measurement of parameters, such as temperature, flow rate and oil pressure at an electromotor-pump unit

  3. Bluetooth-based distributed measurement system

    Science.gov (United States)

    Tang, Baoping; Chen, Zhuo; Wei, Yuguo; Qin, Xiaofeng

    2007-07-01

    A novel distributed wireless measurement system, which is consisted of a base station, wireless intelligent sensors and relay nodes etc, is established by combining of Bluetooth-based wireless transmission, virtual instrument, intelligent sensor, and network. The intelligent sensors mounted on the equipments to be measured acquire various parameters and the Bluetooth relay nodes get the acquired data modulated and sent to the base station, where data analysis and processing are done so that the operational condition of the equipment can be evaluated. The establishment of the distributed measurement system is discussed with a measurement flow chart for the distributed measurement system based on Bluetooth technology, and the advantages and disadvantages of the system are analyzed at the end of the paper and the measurement system has successfully been used in Daqing oilfield, China for measurement of parameters, such as temperature, flow rate and oil pressure at an electromotor-pump unit.

  4. Bluetooth-based distributed measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Tang Baoping; Chen Zhuo; Wei Yuguo; Qin Xiaofeng [Department of Mechatronics, College of Mechanical Engineering, Chongqing University, Chongqing, 400030 (China)

    2007-07-15

    A novel distributed wireless measurement system, which is consisted of a base station, wireless intelligent sensors and relay nodes etc, is established by combining of Bluetooth-based wireless transmission, virtual instrument, intelligent sensor, and network. The intelligent sensors mounted on the equipments to be measured acquire various parameters and the Bluetooth relay nodes get the acquired data modulated and sent to the base station, where data analysis and processing are done so that the operational condition of the equipment can be evaluated. The establishment of the distributed measurement system is discussed with a measurement flow chart for the distributed measurement system based on Bluetooth technology, and the advantages and disadvantages of the system are analyzed at the end of the paper and the measurement system has successfully been used in Daqing oilfield, China for measurement of parameters, such as temperature, flow rate and oil pressure at an electromotor-pump unit.

  5. Measuring Externalities in Program Evaluation

    NARCIS (Netherlands)

    Janssens, Wendy

    2005-01-01

    Impact evaluations of development programmes usually focus on a comparison of participants with a control group. However, if the programme generates externalities for non-participants such an approach will capture only part of the programme's impact. Based on a unique large-scale quantitative survey

  6. Power Curve Measurements, AEP evaluation

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Vesth, Allan

    The purpose of this report is to quantify the production increase on a given turbine with respect to another given turbine. The used methodology is the “side by side” comparison method, provided by the client. This method involves the use of two neighboring turbines and it is based on the assumpt...... on the assumption that the wind field in front of the tested turbines is statistically the same (i.e. has in average the same mean wind speed conditions in front of both turbines). The method is only used for the evaluation of a relative change in the AEP, not the AEP itself....

  7. Power Curve Measurements, AEP evaluation

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Vesth, Allan

    The purpose of this report is to quantify the production increase on a given turbine with respect to another given turbine. The used methodology is the “side by side” comparison method, provided by the client. This method involves the use of two neighboring turbines and it is based on the assumpt...... on the assumption that the wind field in front of the tested turbines is statistically the same (i.e. has in average the same mean wind speed conditions in front of both turbines). The method is only used for the evaluation of a relative change in the AEP, not the AEP itself.......The purpose of this report is to quantify the production increase on a given turbine with respect to another given turbine. The used methodology is the “side by side” comparison method, provided by the client. This method involves the use of two neighboring turbines and it is based...

  8. Evaluating groundwater flow using passive electrical measurements

    Science.gov (United States)

    Voytek, E.; Revil, A.; Singha, K.

    2016-12-01

    Accurate quantification of groundwater flow patterns, both in magnitude and direction, is a necessary component of evaluating any hydrologic system. Groundwater flow patterns are often determined using a dense network of wells or piezometers, which can be limited due to logistical or regulatory constraints. The self-potential (SP) method, a passive geophysical technique that relies on currents generated by water movement through porous materials, is a re-emerging alternative or addition to traditional piezometer networks. Naturally generated currents can be measured as voltage differences at the ground surface using only two electrodes, or a more complex electrode array. While the association between SP measurements and groundwater flow was observed as early as 1890s, the method has seen resurgence in hydrology since the governing equations were refined in the 1980s. The method can be used to analyze hydrologic processes at various temporal and spatial scales. Here we present the results of multiple SP surveys collected a multiple scales (1 to 10s of meters). Here single SP grid surveys are used to evaluate flow patterns through artic hillslopes at a discrete point in time. Additionally, a coupled groundwater and electrical model is used to analyze multiple SP data sets to evaluate seasonal changes in groundwater flow through an alpine meadow.

  9. Proton gyromagnetic precision measurement system

    International Nuclear Information System (INIS)

    Zhu Deming; Deming Zhu

    1991-01-01

    A computerized control and measurement system used in the proton gyromagnetic precision meausrement is descirbed. It adopts the CAMAC data acquisition equipment, using on-line control and analysis with the HP85 and PDP-11/60 computer systems. It also adopts the RSX11M computer operation system, and the control software is written in FORTRAN language

  10. Control measurement system in purex process

    International Nuclear Information System (INIS)

    Mani, V.V.S.

    1985-01-01

    The dependence of a bulk facility handling Purex Process on the control measurement system for evaluating the process performance needs hardly be emphasized. process control, Plant control, inventory control and quality control are the four components of the control measurement system. The scope and requirements of each component are different and the measurement methods are selected accordingly. However, each measurement system has six important elements. These are described in detail. The quality assurance programme carried out by the laboratory as a mechanism through which the quality of measurements is regularly tested and stated in quantitative terms is also explained in terms of internal and external quality assurance, with examples. Suggestions for making the control measurement system more responsive to the operational needs in future are also briefly discussed. (author)

  11. Significance of apparent diffusion coefficient measurement for the differential diagnosis of multiple system atrophy, progressive supranuclear palsy, and Parkinson's disease: evaluation by 3.0-T MR imaging

    International Nuclear Information System (INIS)

    Tsukamoto, Kazumichi; Kanasaki, Yoshiko; Kakite, Suguru; Fujii, Shinya; Kaminou, Toshio; Ogawa, Toshihide; Matsusue, Eiji

    2012-01-01

    The clinical differentiation of Parkinson's disease (PD) from multiple system atrophy (MSA) and progressive supranuclear palsy (PSP) may be challenging, especially in their early stages. The aim of this study was to evaluate the utility of apparent diffusion coefficient (ADC) measurement to distinguish among these degenerative disorders. Twenty-five MSA, 20 PSP, and 17 PD patients and 18 healthy controls were retrospectively studied. Axial diffusion-weighted and T2-weighted images were obtained using a 3-T MR system. Regions of interest (ROIs) were precisely placed in the midbrain, pons, putamen, globus pallidus, caudate nucleus, thalamus, superior cerebellar peduncle, middle cerebellar peduncle, cerebellar white matter, and cerebellar dentate nucleus, and the regional ADC (rADC) value was calculated in each ROI. In MSA, rADC values in the pons, middle cerebellar peduncle, cerebellar white matter, and cerebellar dentate nucleus were significantly higher than in PSP, PD, and controls. Furthermore, rADC values in the posterior putamen were significantly higher in MSA than in PSP and controls. In PSP, rADC values were significantly higher in the globus pallidus and midbrain than in MSA, PD, and controls. Furthermore, rADC values in the caudate nucleus and superior cerebellar peduncle were significantly higher in PSP than in MSA and controls. In PD, there were no significant differences in the rADC values compared to in MSA, PSP, and controls in all regions. Evaluation of rADC values in characteristic lesions in MSA, PSP, and PD by placing ROIs using 3-T systems can provide useful additional information for differentiating these disorders. (orig.)

  12. INFORMATION SECURITY IN MOBILE MODULAR MEASURING SYSTEMS

    Directory of Open Access Journals (Sweden)

    A. N. Tkhishev

    2017-01-01

    Full Text Available A special aspect of aircraft test is carrying out both flight evaluation and ground operation evaluation in a structure of flying aids and special tools equipment. The specific of flight and sea tests involve metering in offshore zone, which excludes the possibility of fixed geodetically related measuring tools. In this regard, the specific role is acquired by shipbased measurement systems, in particular the mobile modular measuring systems. Information processed in the mobile modular measurement systems is a critical resource having a high level of confidentiality. When carrying out their functions, it should be implemented a proper information control of the mobile modular measurement systems to ensure their protection from the risk of data leakage, modification or loss, i.e. to ensure a certain level of information security. Due to the specific of their application it is difficult to solve the problems of information security in such complexes. The intruder model, the threat model, the security requirements generated for fixed informatization objects are not applicable to mobile systems. It was concluded that the advanced mobile modular measuring systems designed for flight experiments monitoring and control should be created due to necessary information protection measures and means. The article contains a diagram of security requirements formation, starting with the data envelopment analysis and ending with the practical implementation. The information security probabilistic model applied to mobile modular measurement systems is developed. The list of current security threats based on the environment and specific of the mobile measurement system functioning is examined. The probabilistic model of the information security evaluation is given. The problems of vulnerabilities transformation of designed information system into the security targets with the subsequent formation of the functional and trust requirements list are examined.

  13. Economic framework for information system evaluation

    International Nuclear Information System (INIS)

    King, D.W.; Roderer, N.K.

    1979-01-01

    In the evaluation of complex information systems, it is useful to work within a generalized economic framework. This framework is based on consideration of four evaluation levels, including those associated with the overall system, system functions, products and services, and activities. Measures of cost and output can be defined at each level, with output measures related to volume of activity, performance, effectiveness, and benefit. The description of this framework includes definitions of the terminology used. Examples of the application of the framework to specific information system evaluations are also given. 4 figures

  14. Evaluation of the Sebia Capillarys 3 Tera and the Bio-Rad D-100 Systems for the Measurement of Hemoglobin A1c.

    Science.gov (United States)

    Herpol, Margaux; Lanckmans, Katrien; Van Neyghem, Stefaan; Clement, Pascale; Crevits, Stefanie; De Crem, Kim; Gorus, Frans K; Weets, Ilse

    2016-07-01

    We evaluated the Bio-Rad (Irvine, CA) D-100 and the Sebia (Lisses, France) Capillarys 3 Tera for the measurement of hemoglobin A1c (HbA1c) in venous blood samples. Whole-blood samples and control material were analyzed with the D-100 and Capillarys 3 Tera and compared with our routine method, HLC-723G7 (Tosoh, Tokyo, Japan). An evaluation protocol to test precision, trueness, linearity, carryover, and selectivity was set up according to Clinical and Laboratory Standards Institute guidelines. The results were presented in National Glycohemoglobin Standardization Program and International Federation of Clinical Chemistry (IFCC) units. Both systems showed excellent precision (total coefficients of variation hemoglobin (≤0.5 mmol/L potassium cyanate), hemoglobin variants, bilirubin (≤15 mg/dL), and triglycerides (≤3,360 mg/dL). The Bio-Rad D-100 and the Sebia Capillarys 3 Tera instruments performed well for the determination of HbA1c in terms of quality criteria as well as for sample throughput. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. External Evaluation Measures for Subspace Clustering

    DEFF Research Database (Denmark)

    Günnemann, Stephan; Färber, Ines; Müller, Emmanuel

    2011-01-01

    research area of subspace clustering. We formalize general quality criteria for subspace clustering measures not yet addressed in the literature. We compare the existing external evaluation methods based on these criteria and pinpoint limitations. We propose a novel external evaluation measure which meets...

  16. Facilities projects performance measurement system

    International Nuclear Information System (INIS)

    Erben, J.F.

    1979-01-01

    The two DOE-owned facilities at Hanford, the Fuels and Materials Examination Facility (FMEF), and the Fusion Materials Irradiation Test Facility (FMIT), are described. The performance measurement systems used at these two facilities are next described

  17. Automated measuring systems. Automatisierte Messsysteme

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    Microprocessors have become a regular component of automated measuring systems. Experts offer their experience and basic information in 24 lectures and 10 poster presentations. The focus is on the following: Automated measuring, computer and microprocessor use, sensor technique, actuator technique, communication, interfaces, man-system interaction, distrubance tolerance and availability as well as uses. A discussion meeting is dedicated to the theme complex sensor digital signal, sensor interface and sensor bus.

  18. Acoustic building infiltration measurement system

    Science.gov (United States)

    Muehleisen, Ralph T.; Raman, Ganesh

    2018-04-10

    Systems and methods of detecting and identifying a leak from a container or building. Acoustic pressure and velocity are measured. Acoustic properties are acquired from the measured values. The acoustic properties are converted to infiltration/leakage information. Nearfield Acoustic Holography (NAH) may be one method to detect the leakages from a container by locating the noise sources.

  19. Evaluation of the accuracy, consistency, and stability of measurements of the Planck constant used in the redefinition of the international system of units

    Science.gov (United States)

    Possolo, Antonio; Schlamminger, Stephan; Stoudt, Sara; Pratt, Jon R.; Williams, Carl J.

    2018-02-01

    The Consultative Committee for Mass and related quantities (CCM), of the International Committee for weights and measures (CIPM), has recently declared the readiness of the community to support the redefinition of the international system of units (SI) at the next meeting of the General Conference on Weights and Measures (CGPM) scheduled for November, 2018. Such redefinition will replace the international prototype of the Kilogram (IPK), as the definition and sole primary realization of the unit of mass, with a definition involving the Planck constant, h. This redefinition in terms of a fundamental constant of nature will enable widespread primary realizations not only of the kilogram but also of its multiples and sub-multiples, best to address the full range of practical needs in the measurement of mass. We review and discuss the statistical models and statistical data reductions, uncertainty evaluations, and substantive arguments that support the verification of several technical preconditions for the redefinition that the CCM has established, and whose verification the CCM has affirmed. These conditions relate to the accuracy and mutual consistency of qualifying measurement results. We review also an issue that has surfaced only recently, concerning the convergence toward a stable value, of the historical values that the task group on fundamental constants of the committee on Data for Science and Technology CODATA-TGFC has recommended for h over the years, even though the CCM has not deemed this issue to be relevant. We conclude that no statistically significant trend can be substantiated for these recommended values, but note that cumulative consensus values that may be derived from the historical measurement results for h seem to have converged while continuing to exhibit fluctuations that are typical of a process in statistical control. Finally, we argue that the most recent consensus value derived from the best measurements available for h, obtained using

  20. Establishing System Measures of Effectiveness

    Science.gov (United States)

    2001-03-01

    Halpin, 1991] Andriole, Stephen J. and Stanley M. Halpin, editors. Information Technology for Command and Control: Methods and Tools for Systems...Systems with Models and Objects, New York: Mc Graw -Hill, 1997. [Pawlowski, 1993a] Pawlowski, Thomas J. III, LTC. C3IEW Measures of Effectiveness

  1. Measuring Complexity of SAP Systems

    Directory of Open Access Journals (Sweden)

    Ilja Holub

    2016-10-01

    Full Text Available The paper discusses the reasons of complexity rise in ERP system SAP R/3. It proposes a method for measuring complexity of SAP. Based on this method, the computer program in ABAP for measuring complexity of particular SAP implementation is proposed as a tool for keeping ERP complexity under control. The main principle of the measurement method is counting the number of items or relations in the system. The proposed computer program is based on counting of records in organization tables in SAP.

  2. Airborne Atmospheric Aerosol Measurement System

    Science.gov (United States)

    Ahn, K.; Park, Y.; Eun, H.; Lee, H.

    2015-12-01

    It is important to understand the atmospheric aerosols compositions and size distributions since they greatly affect the environment and human health. Particles in the convection layer have been a great concern in global climate changes. To understand these characteristics satellite, aircraft, and radio sonde measurement methods have usually been used. An aircraft aerosol sampling using a filter and/or impactor was the method commonly used (Jay, 2003). However, the flight speed particle sampling had some technical limitations (Hermann, 2001). Moreover, the flight legal limit, altitude, prohibited airspace, flight time, and cost was another demerit. To overcome some of these restrictions, Tethered Balloon Package System (T.B.P.S.) and Recoverable Sonde System(R.S.S.) were developed with a very light optical particle counter (OPC), impactor, and condensation particle counter (CPC). Not only does it collect and measure atmospheric aerosols depending on altitudes, but it also monitors the atmospheric conditions, temperature, humidity, wind velocity, pressure, GPS data, during the measurement (Eun, 2013). In this research, atmospheric aerosol measurement using T.B.P.S. in Ansan area is performed and the measurement results will be presented. The system can also be mounted to an unmanned aerial vehicle (UAV) and create an aerial particle concentration map. Finally, we will present measurement data using Tethered Balloon Package System (T.B.P.S.) and R.S.S (Recoverable Sonde System).

  3. Distance measures for image segmentation evaluation

    OpenAIRE

    Monteiro, Fernando C.; Campilho, Aurélio

    2012-01-01

    In this paper we present a study of evaluation measures that enable the quantification of the quality of an image segmentation result. Despite significant advances in image segmentation techniques, evaluation of these techniques thus far has been largely subjective. Typically, the effectiveness of a new algorithm is demonstrated only by the presentation of a few segmented images and is otherwise left to subjective evaluation by the reader. Such an evaluation criterion can be useful for differ...

  4. Nuclear systems of level measurement

    International Nuclear Information System (INIS)

    Lara, A.J.; Cabrera, M.J.

    1992-01-01

    In the industry there are processes in which is necessary to maintain the products level controlled which are handled for their transformation. The majority of such processes and by the operation conditions, they do not admit measure systems of level of invasive type then the application of nuclear techniques for level measurement results a big aid in these cases, since all the system installation is situated beyond frontiers of vessels that contain the product for measuring. In the Department of Nuclear Technology Applications of Mexican Petroleum Institute was developed a level measurement system by gamma rays transmission which operates in the Low Density Polyethylene plant of Petrochemical Complex Escolin at Poza Rica, Veracruz, Mexico. (Author)

  5. Evaluating neural networks and artificial intelligence systems

    Science.gov (United States)

    Alberts, David S.

    1994-02-01

    Systems have no intrinsic value in and of themselves, but rather derive value from the contributions they make to the missions, decisions, and tasks they are intended to support. The estimation of the cost-effectiveness of systems is a prerequisite for rational planning, budgeting, and investment documents. Neural network and expert system applications, although similar in their incorporation of a significant amount of decision-making capability, differ from each other in ways that affect the manner in which they can be evaluated. Both these types of systems are, by definition, evolutionary systems, which also impacts their evaluation. This paper discusses key aspects of neural network and expert system applications and their impact on the evaluation process. A practical approach or methodology for evaluating a certain class of expert systems that are particularly difficult to measure using traditional evaluation approaches is presented.

  6. Pervious Pavement System Evaluation

    Science.gov (United States)

    Porous pavement is a low impact development stormwater control. The Urban Watershed Management Branch is evaluating interlocking concrete pavers as a popular implementation. The pavers themselves are impermeable, but the spaces between the pavers are backfilled with washed, grade...

  7. Evaluation Systems, Ethics, and Development Evaluation

    Science.gov (United States)

    Thomas, Vinod

    2010-01-01

    After some 65 years of international development assistance, it is still difficult to show the effectiveness of aid in ways that are fully convincing. In part, this reflects inadequacies in the evaluation systems of the bilateral, multilateral, and global organizations that provide official development aid. Underlying these weaknesses often are a…

  8. ASUPT Automated Objective Performance Measurement System.

    Science.gov (United States)

    Waag, Wayne L.; And Others

    To realize its full research potential, a need exists for the development of an automated objective pilot performance evaluation system for use in the Advanced Simulation in Undergraduate Pilot Training (ASUPT) facility. The present report documents the approach taken for the development of performance measures and also presents data collected…

  9. Computerized system for measuring cerebral metabolism

    International Nuclear Information System (INIS)

    McGlone, J.S.; Hibbard, L.S.; Hawkins, R.A.; Kasturi, R.

    1987-01-01

    A computerized stereotactic measurement system for evaluating rat brain metabolism was developed to utilize the large amount of data generated by quantitative autoradiography. Conventional methods of measurement only analyze a small percent of these data because these methods are limited by instrument design and the subjectiveness of the investigator. However, a computerized system allows digital images to be analyzed by placing data at their appropriate three-dimensional stereotactic coordinates. The system automatically registers experimental data to a standard three-dimensional image using alignment, scaling, and matching operations. Metabolic activity in different neuronal structures is then measured by generating digital masks and superimposing them on to experimental data. Several experimental data sets were evaluated and it was noticed that the structures measured by the computerized system, had in general, lower metabolic activity than manual measurements had indicated. This was expected because the computerized system measured the structure over its volume while the manual readings were taken from the most active metabolic area of a particular structure

  10. Peer Evaluation Can Reliably Measure Local Knowledge

    Science.gov (United States)

    Reyes-García, Victoria; Díaz-Reviriego, Isabel; Duda, Romain; Fernández-Llamazares, Álvaro; Gallois, Sandrine; Guèze, Maximilien; Napitupulu, Lucentezza; Pyhälä, Aili

    2016-01-01

    We assess the consistency of measures of individual local ecological knowledge obtained through peer evaluation against three standard measures: identification tasks, structured questionnaires, and self-reported skills questionnaires. We collected ethnographic information among the Baka (Congo), the Punan (Borneo), and the Tsimane' (Amazon) to…

  11. Evaluation of performance, acceptance, and compliance of an auto-injector in healthy and rheumatoid arthritic subjects measured by a motion capture system.

    Science.gov (United States)

    Xiao, Xiao; Li, Wei; Clawson, Corbin; Karvani, David; Sondag, Perceval; Hahn, James K

    2018-01-01

    The study aimed to develop a motion capture system that can track, visualize, and analyze the entire performance of self-injection with the auto-injector. Each of nine healthy subjects and 29 rheumatoid arthritic (RA) patients with different degrees of hand disability performed two simulated injections into an injection pad while six degrees of freedom (DOF) motions of the auto-injector and the injection pad were captured. We quantitatively measured the performance of the injection by calculating needle displacement from the motion trajectories. The max, mean, and SD of needle displacement were analyzed. Assessments of device acceptance and usability were evaluated by a survey questionnaire and independent observations of compliance with the device instruction for use (IFU). A total of 80 simulated injections were performed. Our results showed a similar level of performance among all the subjects with slightly larger, but not statistically significant, needle displacement in the RA group. In particular, no significant effects regarding previous experience in self-injection, grip method, pain in hand, and Cochin score in the RA group were found to have an impact on the mean needle displacement. Moreover, the analysis of needle displacement for different durations of injections indicated that most of the subjects reached their personal maximum displacement in 15 seconds and remained steady or exhibited a small amount of increase from 15 to 60 seconds. Device acceptance was high for most of the questions (ie, >4; >80%) based on a 0-5-point scale or percentage of acceptance. The overall compliance with the device IFU was high for the first injection (96.05%) and reached 98.02% for the second injection. We demonstrated the feasibility of tracking the motions of injection to measure the performance of simulated self-injection. The comparisons of needle displacement showed that even RA patients with severe hand disability could properly perform self-injection with this

  12. Regarding KUR Reactivity Measurement System

    International Nuclear Information System (INIS)

    Nakamori, Akira; Hasegawa, Kei; Tsuchiyama, Tatsuo; Yamamoto, Toshihiro; Okumura, Ryo; Sano, Tadafumi

    2012-01-01

    This article reported: (1) the outline of the reactivity measurement system of Kyoto University Research Reactor (KUR), (2) the calibration data of control rod, (3) the problems and the countermeasures for range switching of linear output meter. For the laptop PC for the reactivity measurement system, there are four input signals: (1) linear output meter, (2) logarithmic output meter, (3) core temperature gauge, and (4) control rod position. The hardware of reactivity measurement system is controlled with Labview installed on the laptop. Output, reactivity, reactor period, and the change in reactivity due to temperature effect or Xenon effect are internally calculated and displayed in real-time with Labview based on the four signals above. Calculation results are recorded in the form of a spreadsheet. At KUR, the reactor core arrangement was changed, so the control rod was re-calibrated. At this time, calculated and experimental values of reactivity based on the reactivity measurement system were compared, and it was confirmed that the reactivity calculation by Labview was accurate. The range switching of linear output meter in the nuclear instrumentation should automatically change within the laptop, however sometimes this did not function properly in the early stage. It was speculated that undefined percent values during the transition of percent value were included in the calculation and caused calculation errors. The range switching started working properly after fixing this issue. (S.K.)

  13. Quality measures for nurse practitioner practice evaluation.

    Science.gov (United States)

    Kleinpell, Ruth; Kapu, April N

    2017-08-01

    Evaluating the impact of nurse practitioner (NP) practice has become a priority area of focus for demonstrating outcomes. A number of quality measures are available to enable practice-specific evaluation of NP roles and initiatives. This article reviews sources of quality measures that can be used to facilitate quantifying the outcomes of NP practice as part of an overall evaluation agenda. National resources and published literature on NP quality measures were reviewed. Various resources and toolkits exist to assist NPs in identifying outcomes of practice using quality measures. The need to demonstrate outcomes of NP practice remains an ongoing priority area regardless of the clinical practice setting. A variety of sources of quality measures exist that can be used to showcase the effect of NP care. The use of quality measures can be effectively integrated into evaluation of NP role and NP-directed initiatives to demonstrate impact, and enhance the conduct of an NP outcomes assessment. The use of organizational, NP-specific, and national-related quality measures can help to showcase how NP care improves the quality, safety, and costs of health care. ©2017 American Association of Nurse Practitioners.

  14. Design and validation of a 3D virtual reality desktop system for sonographic length and volume measurements in early pregnancy evaluation.

    Science.gov (United States)

    Baken, Leonie; van Gruting, Isabelle M A; Steegers, Eric A P; van der Spek, Peter J; Exalto, Niek; Koning, Anton H J

    2015-03-01

    To design and validate a desktop virtual reality (VR) system, for presentation and assessment of volumetric data, based on commercially off-the-shelf hardware as an alternative to a fully immersive CAVE-like I-Space VR system. We designed a desktop VR system, using a three-dimensional (3D) monitor and a six degrees-of-freedom tracking system. A personal computer uses the V-Scope (Erasmus MC, Rotterdam, The Netherlands) volume-rendering application, developed for the I-Space, to create a hologram of volumetric data. Inter- and intraobserver reliability for crown-rump length and embryonic volume measurements are investigated using Bland-Altman plots and intraclass correlation coefficients. Time required for the measurements was recorded. Comparing the I-Space and the desktop VR system, the mean difference for crown-rump length is -0.34% (limits of agreement -2.58-1.89, ±2.24%) and for embryonic volume -0.92% (limits of agreement -6.97-5.13, ±6.05%). Intra- and interobserver intraclass correlation coefficients of the desktop VR system were all >0.99. Measurement times were longer on the desktop VR system compared with the I-Space, but the differences were not statistically significant. A user-friendly desktop VR system can be put together using commercially off-the-shelf hardware at an acceptable price. This system provides a valid and reliable method for embryonic length and volume measurements and can be used in clinical practice. © 2014 Wiley Periodicals, Inc.

  15. Evaluating and Measuring the Return on Investment of an Emergency Center Health Care Professional Picture Archiving and Communication Systems Training Program

    Science.gov (United States)

    Roelandt, James P.

    2012-01-01

    Picture archiving and communication system (PACS) workflow directly affects the quality of emergency patient care through radiology exam turn-around times and the speed of delivery of diagnostic radiology results. This study was a mixed methods training and performance improvement study that evaluated the effectiveness and value of a hospital…

  16. Assessment and evaluation of the employment of the Midshipman Information System (MIDS) as a performance measurement tool by Company Officers at the United States Naval Academy

    OpenAIRE

    Luckett, Michael D.; Oden, David M.

    2001-01-01

    This research first examines the use of the Midshipmen Information System (MIDS) by faculty, staff and midshipmen as a performance measurement tool at the United States Naval Academy. Specifically, this project examines how Company Officers use MIDS to measure the performance and development of the midshipmen over time, what metrics they believe are important to midshipmen development, how current MIDS functionality meets the needs of end users and recommendations for improvement of the overa...

  17. Measurement system for large motions

    International Nuclear Information System (INIS)

    Noyes, R.; Davies, L.; Kalinowski, J.; Stubbs, T.

    1979-05-01

    The system used to measure the response of geologic media to stress waves generated during and after underground tests performed by the Lawrence Livermore Laboratory (LLL) at the Department of Energy's Nevada Test Site (NTS) is described. Included are descriptions of the system transducers and accelerometers, the procedures used in calibrating and packaging the system at the North Las Vegas Facility of EG and G, Inc., the positioning of equipment during fielding activities at NTS, and the procedures used at LLL's facilities in California to reduce and analyze the data recorded on magnetic tape at NTS during an underground nuclear explosion. In summarizing, the authors give the system high marks, attributing its success to good basic design, careful installation, and rigorous calibration and data analysis techniques applied with good judgement on the part of the instrumentation engineers and data analysts. 10 figures

  18. Evaluating measurement accuracy a practical approach

    CERN Document Server

    Rabinovich, Semyon G

    2013-01-01

    The goal of Evaluating Measurement Accuracy: A Practical Approach is to present methods for estimating the accuracy of measurements performed in industry, trade, and scientific research. From developing the theory of indirect measurements to proposing new methods of reduction, transformation, and enumeration, this work encompasses the full range of measurement data processing. It includes many examples that illustrate the application of general theory to typical problems encountered in measurement practice. As a result, the book serves as an inclusive reference work for data processing of all types of measurements: single and multiple, combined and simultaneous, direct (both linear and nonlinear), and indirect (both dependent and independent). It is a working tool for experimental scientists and engineers of all disciplines who work with instrumentation. It is also a good resource for natural science and engineering students and for technicians performing measurements in industry. A key feature of the book is...

  19. Evaluating measurement accuracy a practical approach

    CERN Document Server

    Rabinovich, Semyon G

    2017-01-01

    This book presents a systematic and comprehensive exposition of the theory of measurement accuracy and provides solutions that fill significant and long-standing gaps in the classical theory. It eliminates the shortcomings of the classical theory by including methods for estimating accuracy of single measurements, the most common type of measurement. The book also develops methods of reduction and enumeration for indirect measurements, which do not require Taylor series and produce a precise solution to this problem. It produces grounded methods and recommendations for summation of errors. The monograph also analyzes and critiques two foundation metrological documents, the International Vocabulary of Metrology (VIM) and the Guide to the Expression of Uncertainty in Measurement (GUM), and discusses directions for their revision. This new edition adds a step-by-step guide on how to evaluate measurement accuracy and recommendations on how to calculate systematic error of multiple measurements. There is also an e...

  20. Evaluation of Columbia, USMARC-Composite, Suffolk, and Texel rams as terminal sires in an extensive rangeland production system: VIII. Quality measures of lamb longissimus dorsi.

    Science.gov (United States)

    Mousel, M R; Notter, D R; Leeds, T D; Zerby, H N; Moeller, S J; Taylor, J B; Lewis, G S

    2014-07-01

    Quality measures of lamb longissimus dorsi were evaluated in 514 crossbred wether lambs to assess sire breed differences. Wethers were produced over 3 yr from single-sire matings of 22 Columbia, 22 U.S. Meat Animal Research Center (USMARC)-Composite (Composite), 21 Suffolk, and 17 Texel rams to adult Rambouillet ewes. Lambs were reared to weaning in an extensive western rangeland production system and finished in a feedlot on a high-energy finishing diet. One of three harvest groups were randomly assigned to each lamb, and lambs were transported to The Ohio State University abattoir when the mean BW of wethers remaining in the feedlot reached 54.4, 61.2, or 68.0 kg. After harvest, subjective lean quality scores were assigned and LM pH (immediately after and 24 h after harvest), color (quantified as Minolta L*, a*, and b*), intramuscular fat (IMF), cooking loss percentage, and Warner-Bratzler shear force (WBSF) were determined. Statistical models included fixed effects of sire breed, year of birth, and harvest group and random effects of sire (nested within sire breed and year) and maternal grandsire. Year and harvest group were significant (P 0.28). At comparable numbers of days on feed, Texel-sired wethers had the greatest (more desirable; P lambs were intermediate and Columbia-sired lambs had the lowest (less desirable). Minolta L* values were greater (P lambs, although this difference is not visually discernible by humans. No significant (P > 0.05) sire breed effects were detected for LM pH at or 24 h after harvest, Minolta a* and b*, IMF, percentage of cooking loss, and WBSF at comparable numbers of days on feed. At comparable chilled carcass weight, significant (P lambs had greater scores than Columbia- and Suffolk-sired lambs, but Composite-sired lambs did not differ from lambs sired by the other sire breeds. Sire breed effects were not detected (P > 0.15) for LM pH at or 24 h after harvest, Minolta L*, a*, and b*, cooking loss percentage, IMF, and WBSF at

  1. Measurement techniques of LC display systems

    Science.gov (United States)

    Kosmowski, Bogdan B.; Becker, Michael E.; Neumeier, Juergen

    1993-10-01

    The strong increase of applications of liquid crystal displays in various areas (measuring, medical equipment, automotive, telecommunication, office, etc.) has forced the demand for the adequate specification of the LCDs performances. The optical, electro-optical and spectral properties of LCDs are strongly dependent on viewing direction, electrical driving conditions, illumination and temperature. All these quantities have to be precisely controlled, when one of them is varied, the resulting optical response of the object is recorded. In this paper we present measuring methods proposed for LCD panels and the computer controlled measuring system (DMS) for their evaluation.

  2. MTA Computer Based Evaluation System.

    Science.gov (United States)

    Brenner, Lisa P.; And Others

    The MTA PLATO-based evaluation system, which has been implemented by a consortium of schools of medical technology, is designed to be general-purpose, modular, data-driven, and interactive, and to accommodate other national and local item banks. The system provides a comprehensive interactive item-banking system in conjunction with online student…

  3. TRU assay system and measurements

    International Nuclear Information System (INIS)

    Brodzinski, R.L.

    1984-02-01

    The measurement of the transuranic content of nuclear products or process residues has become increasingly important for the recovery of fissionable material from spent fuel elements, the identification of commercial fuel elements which have not yet reached full burnup, the measurement and recovery of transuranics from discarded or stored waste materials, the determination of the transuranic content in high gamma activity waste material scheduled for disposal, compliance with 10CFR61 by land burial operators/shippers, and the satisfaction of accountability requirements. Active neutron interrogation techniques measure either the prompt neutrons or the beta delayed neutrons from fission products following induced fission. These techniques normally only measure fissile transuranics ( 235 U, 239 Pu, and 241 Pu) and are commonly applied only to contact handleable waste. Passive neutron interrogation techniques, on the other hand, are capable of measuring all transuranics except 235 U with adequate sensitivity and will work on both contact handleable and high gamma activity wastes. Since the passive techniques are senstitive to a wider spectrum of transuranic isotopes than the active techniques, substantially less complex and less expensive than the active systems, and they have proven techniques for measuring small quantities of TRU in high gamma activity packages, the passive neutron TRU assay technology was chosen for development into the instruments discussed in this paper

  4. A propagation-measurement-based evaluation of channel characteristics and models pertinent to the expansion of mobile radio systems to frequencies beyond 2 GHz

    NARCIS (Netherlands)

    Bultitude, R.J.C.; Schenk, T.C.W.; Op de Kamp, N.A.A.; Adnani, N.

    2007-01-01

    64This paper concerns the measurement-based comparison of urban microcellular mobile radio channel characteristics at 1.9 GHz and a higher frequency, i.e., 5.8 GHz, where future wireless systems could operate. Characteristics that are reported include transmission loss, root-mean-square delay

  5. DEVELOPMENT OF EVALUATION OF A QUANTITATIVE VIDEO-FLUORESCENCE IMAGING SYSTEM AND FLUORESCENT TRACER FOR MEASURING TRANSFER OF PESTICIDE RESIDUES FROM SURFACES TO HANDS WITH REPEATED CONTACTS

    Science.gov (United States)

    A video imaging system and the associated quantification methods have been developed for measurement of the transfers of a fluorescent tracer from surfaces to hands. The highly fluorescent compound riboflavin (Vitamin B2), which is also water soluble and non-toxic, was chosen as...

  6. Video integrated measurement system. [Diagnostic display devices

    Energy Technology Data Exchange (ETDEWEB)

    Spector, B.; Eilbert, L.; Finando, S.; Fukuda, F.

    1982-06-01

    A Video Integrated Measurement (VIM) System is described which incorporates the use of various noninvasive diagnostic procedures (moire contourography, electromyography, posturometry, infrared thermography, etc.), used individually or in combination, for the evaluation of neuromusculoskeletal and other disorders and their management with biofeedback and other therapeutic procedures. The system provides for measuring individual diagnostic and therapeutic modes, or multiple modes by split screen superimposition, of real time (actual) images of the patient and idealized (ideal-normal) models on a video monitor, along with analog and digital data, graphics, color, and other transduced symbolic information. It is concluded that this system provides an innovative and efficient method by which the therapist and patient can interact in biofeedback training/learning processes and holds considerable promise for more effective measurement and treatment of a wide variety of physical and behavioral disorders.

  7. Evaluating and measuring impact: where and how?

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    On 12 and 13 November, a workshop on “Evaluation in international organisations” took place at CERN. Fourteen internal auditors and planning and policy analysts, from six different international organisations, discussed whether and how to evaluate the impact of their organisations’ programmes on the target beneficiaries.      Participants of the “Evaluation in international organisations” workshop at CERN. “Evaluation”, a relatively recent but fast growing discipline, deals with the systematic and objective assessment of the impact of policies and programmes on the target beneficiaries – often society at large. In the past few years, other international organisations have created an evaluation function within their internal structure, whose role is to measure the impact of their public policies. “In the first instance we wanted to understand what the difference between evaluation a...

  8. USAF Weapon System Evaluation Program

    National Research Council Canada - National Science Library

    1999-01-01

    During this task period, Schafer Corporation provided engineering services and analysis to the USAF at Eglin AFB, Florida in direct support of the USAF Air-to-Surface Weapon System Evaluation Program (WSEP...

  9. Control Evaluation Information System Savings

    Directory of Open Access Journals (Sweden)

    Eddy Sutedjo

    2011-05-01

    Full Text Available The purpose of this research is to evaluate the control of information system savings in the banking and to identify the weaknesses and problem happened in those saving systems. Research method used are book studies by collecting data and information needed and field studies by interview, observation, questioner, and checklist using COBIT method as a standard to assess the information system control of the company. The expected result about the evaluation result that show in the problem happened and recommendation given as the evaluation report and to give a view about the control done by the company. Conclusion took from this research that this banking company has met standards although some weaknesses still exists in the system.Index Terms - Control Information System, Savings

  10. Lightweight, Miniature Inertial Measurement System

    Science.gov (United States)

    Tang, Liang; Crassidis, Agamemnon

    2012-01-01

    A miniature, lighter-weight, and highly accurate inertial navigation system (INS) is coupled with GPS receivers to provide stable and highly accurate positioning, attitude, and inertial measurements while being subjected to highly dynamic maneuvers. In contrast to conventional methods that use extensive, groundbased, real-time tracking and control units that are expensive, large, and require excessive amounts of power to operate, this method focuses on the development of an estimator that makes use of a low-cost, miniature accelerometer array fused with traditional measurement systems and GPS. Through the use of a position tracking estimation algorithm, onboard accelerometers are numerically integrated and transformed using attitude information to obtain an estimate of position in the inertial frame. Position and velocity estimates are subject to drift due to accelerometer sensor bias and high vibration over time, and so require the integration with GPS information using a Kalman filter to provide highly accurate and reliable inertial tracking estimations. The method implemented here uses the local gravitational field vector. Upon determining the location of the local gravitational field vector relative to two consecutive sensors, the orientation of the device may then be estimated, and the attitude determined. Improved attitude estimates further enhance the inertial position estimates. The device can be powered either by batteries, or by the power source onboard its target platforms. A DB9 port provides the I/O to external systems, and the device is designed to be mounted in a waterproof case for all-weather conditions.

  11. Aerial radiological measuring system program

    International Nuclear Information System (INIS)

    Doyle, J.F.; Boyns, P.K.

    1972-01-01

    The present ARMS aircraft has an effective survey time of four hours. Typical survey altitudes are 300 to 500 feet for terrain surveys and up to 20,000 feet for cloud tracks. A number of special airframe modifications have been made to accommodate the various sensor systems. The ARMS radiation measurement system consists of fourteen 4-inch diameter by 4-inch thick sodium iodide (NaI) detectors, a summing network for the detector signals, single and multichannel analyzers, analog computers, digital display and recording equipment, a doppler radar position computer, and strip chart recorders. Major subsystems include meteorology sensors, multispectral camera systems, and an infrared scanner for thermal mapping. Additional radiation detectors include an alpha spectrometer and a beta counter, used to count filter samples taken from a 150 cfm air sampler, which is a permanent part of the aircraft. A small lead shield houses a 1 / 2 -in. x 3-in. NaI crystal for beta and gamma counting of air filter samples. Several BF 3 neutron detectors are also available for neutron counting. The raw data from the gross gamma count and the gamma spectral measurements are permanently recorded on paper tape, and they must undergo reduction and analysis for final characterization of the radiological properties of the surveyed area. (U.S.)

  12. Evaluation of protection measurements for rural environments

    International Nuclear Information System (INIS)

    Silva, Diogo N.G.; Silva, Fernanda L.; Conti, Luiz F.; Wasserman, Maria Angelica V.; Rochedo, Elaine R.R.

    2011-01-01

    Among the planning activities of actuation in nuclear/radiological emergences, it is included the efficiency evaluation of protection and remediation measurements. From the development of a data base on such measurements for the agricultural areas, the program SIEM was used for effectuation the simulations involving the 137 Cs, 131 I and 90 Sr radionuclides, in scenery previously established for simulation those areas of a 50 km surrounding the Admiral Alvaro Alberto nuclear power plant. The obtained results indicate that the scenery is determinant of efficiency measurements involving various specific factors of each place, such as: agricultural and cattle breeding products, consumption habits of population and the grade of subsistence by the diet items, making not practical the elaboration of predefined generic sceneries. The great dependence on seasoning related to the moment of accident makes inadequate any previous evaluation what soever for evaluation of efficiency of protection and remediation measurements. Therefore, previous decisions are not recommended about the relevance of protection measurements for rural areas. Two classification criteria were defined: (i) the efficiency in reduction the doses in the firs year; and, (i i) efficiency in reduction the dose at long term

  13. Multiplex measuring systems in physics

    International Nuclear Information System (INIS)

    Soroko, L.M.

    1980-01-01

    The principles of operation of multiplex devices used in different spheres of physics are discussed. The ''multiplex'' notion means that the data output of the device is an integral image of the functional dependence under investigation, but not its readings as in usual instruments. The analysis of the present state of developments of the multiplex systems in optics, nuclear magnetic resonance spectroscopy, in time-of-flight spectrometers for slow and fast neutrons, as well as elementary particle detectors, is given. The construction algorithms for the digital codes are presented, the history of development of the multiplex measuring principle is given [ru

  14. Aerial measuring system sensor modeling

    International Nuclear Information System (INIS)

    Detwiler, Rebecca

    2002-01-01

    The AMS fixed-wing and rotary-wing systems are critical National Nuclear Security Administration (NNSA) Emergency Response assets. This project is principally focused on the characterization of the sensors utilized with these systems via radiation transport calculations. The Monte Carlo N-Particle code (MCNP) which has been developed at Los Alamos National Laboratory was used to model the detector response of the AMS fixed wing and helicopter systems. To validate the calculations, benchmark measurements were made for simple source-detector configurations. The fixed-wing system is an important tool in response to incidents involving the release of mixed fission products (a commercial power reactor release), the threat or actual explosion of a Radiological Dispersal Device, and the loss or theft of a large industrial source (a radiography source). Calculations modeled the spectral response for the sensors contained, a 3-element NaI detector pod and HpGe detector, in the relevant energy range of 50 keV to 3 MeV. NaI detector responses were simulated for both point and distributed surface sources as a function of gamma energy and flying altitude. For point sources, photo-peak efficiencies were calculated for a zero radial distance and an offset equal to the altitude. For distributed sources approximating infinite plane, gross count efficiencies were calculated and normalized to a uniform surface deposition of 1 C i/m2

  15. Aerial Measuring System Sensor Modeling

    International Nuclear Information System (INIS)

    Detwiler, R.S.

    2002-01-01

    This project deals with the modeling the Aerial Measuring System (AMS) fixed-wing and rotary-wing sensor systems, which are critical U.S. Department of Energy's National Nuclear Security Administration (NNSA) Consequence Management assets. The fixed-wing system is critical in detecting lost or stolen radiography or medical sources, or mixed fission products as from a commercial power plant release at high flying altitudes. The helicopter is typically used at lower altitudes to determine ground contamination, such as in measuring americium from a plutonium ground dispersal during a cleanup. Since the sensitivity of these instruments as a function of altitude is crucial in estimating detection limits of various ground contaminations and necessary count times, a characterization of their sensitivity as a function of altitude and energy is needed. Experimental data at altitude as well as laboratory benchmarks is important to insure that the strong effects of air attenuation are modeled correctly. The modeling presented here is the first attempt at such a characterization of the equipment for flying altitudes. The sodium iodide (NaI) sensors utilized with these systems were characterized using the Monte Carlo N-Particle code (MCNP) developed at Los Alamos National Laboratory. For the fixed wing system, calculations modeled the spectral response for the 3-element NaI detector pod and High-Purity Germanium (HPGe) detector, in the relevant energy range of 50 keV to 3 MeV. NaI detector responses were simulated for both point and distributed surface sources as a function of gamma energy and flying altitude. For point sources, photopeak efficiencies were calculated for a zero radial distance and an offset equal to the altitude. For distributed sources approximating an infinite plane, gross count efficiencies were calculated and normalized to a uniform surface deposition of 1 microCi/m 2 . The helicopter calculations modeled the transport of americium-241 ( 241 Am) as this is

  16. Integration and evaluation of a position sensor with continuous read-out for use with the Environmental Measurement-While-Drilling Gamma Ray Spectrometer system

    International Nuclear Information System (INIS)

    Normann, R.A.; Lockwood, G.J.; Williams, C.V.; Selph, M.M.

    1998-02-01

    The Environmental Measurement-While-Drilling-Gamma Ray Spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides real-time environmental and drill bit data during drilling operations. The EMWD-GRS technology was demonstrated at Savannah River Site (SRS) F-Area Retention Basin. The EMWD-GRS technology demonstration consisted of continuously monitoring for gamma-radiation-producing contamination while drilling two horizontal boreholes below the backfilled waste retention basin. These boreholes passed near previously sampled locations where concentrations of contaminant levels of cesium had been measured. Contaminant levels continuously recorded by the EMWD-GRS system during drilling were compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples. The results show general agreement between the soil sampling and EMWD-GRS techniques for Cs-137. The EMWD-GRS system has been improved by the integration of an orientation sensor package for position sensing (PS) (EMWD-GRS/PS). This added feature gives the capability of calculating position, which is tied directly to EMWD-GRS sensor data obtained while drilling. The EMWD-GRS/PS system is described and the results of the field tests are presented

  17. Field Measurement and Evaluation of the Passive and Active Solar Heating Systems for Residential Building Based on the Qinghai-Tibetan Plateau Case

    Directory of Open Access Journals (Sweden)

    Zhijian Liu

    2017-10-01

    Full Text Available Passive and active solar heating systems have drawn much attention and are widely used in residence buildings in the Qinghai-Tibetan plateau due to its high radiation intensity. In fact, there is still lack of quantitative evaluation of the passive and active heating effect, especially for residential building in the Qinghai-Tibetan plateau areas. In this study, three kinds of heating strategies, including reference condition, passive solar heating condition and active solar heating condition, were tested in one demonstration residential building. The hourly air temperatures of each room under different conditions were obtained and analyzed. The results show the indoor air temperature in the living room and bedrooms (core zones was much higher than that of other rooms under both passive and active solar heating conditions. In addition, the heating effect with different strategies for core zones of the building was evaluated by the ratio of indoor and outdoor degree hour, which indicates that solar heating could effectively reduce the traditional energy consumption and improve the indoor thermal environment. The passive solar heating could undertake 49.8% degree hours for heating under an evaluation criterion of 14 °C and the active solar heating could undertake 75% degree hours for heating under evaluation criterion of 18 °C, which indicated that solar heating could effectively reduce the traditional energy consumption and improve the indoor thermal environment in this area. These findings could provide reference for the design and application of solar heating in similar climate areas.

  18. "System evaluates system": method for evaluating the efficiency of IS

    Directory of Open Access Journals (Sweden)

    Dita Blazkova

    2016-10-01

    Full Text Available In paper I deal with the possible solution of evaluating the efficiency of information systems in companies. The large number of existing methods used to address the efficiency of information systems is dependent on the subjective responses of the user that may distort output evaluation. Therefore, I propose a method that eliminates the subjective opinion of a user as the primary data source. Applications, which I suggests as part of the method, collects relevant data. In this paper I describe the application in detail. This is a follow-on program on any system that runs parallel with it. The program automatically collects data for evaluation. Data include mainly time data, positions the mouse cursor, printScreens, i-grams of previous, etc. I propose a method of evaluation of the data, which identifies the degree of the friendliness of the information system to the user. Thus, the output of the method is the conclusion whether users, who work with the information system, can handle effectively work with it.

  19. The use of qualitative methods in developing the descriptive systems of preference-based measures of health-related quality of life for use in economic evaluation.

    Science.gov (United States)

    Stevens, Katherine; Palfreyman, Simon

    2012-12-01

    To describe how qualitative methods can be used in the development of descriptive systems of preference-based measures (PBMs) of health-related quality of life. The requirements of the National Institute for Health and Clinical Excellence and other agencies together with the increasing use of patient-reported outcome measures has led to an increase in the demand for PBMs. Recently, interest has grown in developing new PBMs and while previous research on PBMs has mainly focused on the methods of valuation, research into the methods of developing descriptive systems is an emerging field. Traditionally, descriptive systems of PBMs were developed by using top-down methods, where content was derived from existing measures, the literature, or health surveys. A contrasting approach is a bottom-up methodology, which takes the views of patients or laypeople on how their life is affected by their health. This approach generally requires the use of qualitative methods. Qualitative methods lend themselves well to the development of PBMs. They also ensure that the measure has appropriate language, content validity, and responsiveness to change. While the use of qualitative methods in the development of non-PBMs is fairly standard, their use in developing PBMs was until recently nonexistent. In this article, we illustrate the use of qualitative methods by presenting two case studies of recently developed PBMs, one generic and one condition specific. We outline the stages involved, discuss the strengths and weaknesses of the approach, and compare with the top-down approach used in the majority of PBMs to date. Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  20. Evaluation of a centrifuge with rapid turnaround time for the preparation of plasma samples for measurement of common STAT markers on the ACS: 180 system.

    Science.gov (United States)

    Foster, K; Datta, P; Orswell, M; Tasaico, K; Alpert, A; Bluestein, B

    2000-01-01

    Reported is the evaluation of a new centrifugation method, Statspin, that addresses both time and sample separation integrity. The method can successfully separate the plasma fraction from the cellular material in 2 minutes as compared to 20 minutes for the conventional centrifuge method. The Statspin, combined with the ACS:180 system, can generate test results in less than 30 minutes, exclusive of transport to the laboratory. This study demonstrated that the combined technologies offer timing-saving improvements for clinical laboratories offering STAT immunoassays for cardiac markers, endocrine molecules, and therapeutic drugs.

  1. WE-NET substask 3. Conceptual design of total system (Safety measures and evaluation techniques); 1998 nendo suiso riyo kokusai clean energy system gijutsu (WE-NET). 3. Zentai system gainen sekkei anzen taisaku hyoka gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    Under the hydrogen-utilizing international clean energy system technology project WE-NET (World Energy NET Work) in fiscal 1998, researches and studies were conducted to clearly define safety designs and to improve on accident-and-safety analyses. In relation with system safety design, investigations continued into Japanese and foreign manuals and regulations about the handling of hydrogen and its peripherals, and safe design guidelines (draft) were compiled. Anomalies and accidents supposed to be typical of each of the systems concerned were investigated. As for accident-and-safety analyses, incorporation of a turbulence model was studied in relation to models representing the leak, evaporation, and diffusion of liquid hydrogen, and improvement was achieved when the scope of evaluation was enlarged concerning the hydrogen detonation model. The integration of the two models was discussed for the due evaluation of a series of processes of liquid hydrogen leak, evaporation, diffusion, and detonation. Calculation was performed for two assumed accidents, and the results were found to justify the integration of the two models. (NEDO)

  2. System for optimizing activation measurements

    International Nuclear Information System (INIS)

    Antonov, V.A.

    1993-01-01

    Optimization procedures make it possible to perform committed activation investigations, reduce the number of experiments, make them less laborious, and increase their productivity. Separate mathematical functions were investigated for given optimization conditions, and these enable numerical optimal parameter values to be established only in the particular cases of specific techniques and mathematical computer programs. In the known mathematical models insufficient account is taken of the variety and complexity of real nuclide mixtures, the influence of background radiation, and the wide diversity of activation measurement conditions, while numerical methods for solving the optimization problem fail to reveal the laws governing the variations of the activation parameters and their functional interdependences. An optimization method was proposed in which was mainly used to estimate the time intervals for activation measurements of a mononuclide, binary or ternary nuclide mixture. However, by forming a mathematical model of activation processes it becomes possible to extend the number of nuclides in the mixture and to take account of the influence of background radiation and the diversity of the measurement alternatives. The analytical expressions and nomograms obtained can be used to determine the number of measurements, their minimum errors, their sensitivities when estimating the quantity of the tracer nuclide, the permissible quantity of interfering nuclides, the permissible background radiation intensity, and the flux of activating radiation. In the worker described herein these investigations are generalized to include spectrally resolved detection of the activation effect in the presence of the tracer and the interfering nuclides. The analytical expressions are combined into a system from which the optimal activation parameters can be found under different given conditions

  3. Integrated system for seismic evaluations

    International Nuclear Information System (INIS)

    Xu, J.; Philippacopoulos, A.J.; Miller, C.A.; Costantino, C.J.; Graves, H.

    1989-01-01

    This paper describes the various features of the seismic module of the CARES system (computer analysis for rapid evaluation of structures). This system was developed to perform rapid evaluations of structural behavior and capability of nuclear power plant facilities. The CARES is structural in a modular format. Each module performs a specific type of analysis i.e., static or dynamic, linear or nonlinear, etc. This paper describes the features of the seismic module in particular. The development of the seismic modules of the CARES system is based on an approach which incorporates major aspects of seismic analysis currently employed by the industry into an integrated system that allows for carrying out interactively computations of structural response to seismic motions. The code operates on a PC computer system and has multi-graphics capabilities

  4. Integral measurement system for radon

    International Nuclear Information System (INIS)

    Garcia H, J.M.; Pena E, R.

    1996-01-01

    The Integral measurement system for Radon is an equipment to detect, counting and storage data of alpha particles produced by Radon 222 which is emanated through the terrestrial peel surface. This equipment was designed in the Special Designs Department of the National Institute of Nuclear Research. It supplies information about the behavior at long time (41 days) on each type of alpha radiation that is present into the environment as well as into the terrestrial peel. The program is formed by an User program, where it is possible to determine the operation parameters of a portable probe that contains, a semiconductor detector, a microprocessor as a control central unit, a real time clock and calendar to determine the occurred events chronology, a non-volatile memory device for storage the acquired data and an interface to establish the serial communications with other personal computers. (Author)

  5. Integration and Evaluation of a Position Sensor with Continuous Read-Out for use with the Environmental Measurement-While-Drilling Gamma Ray Spectrometer System

    International Nuclear Information System (INIS)

    Lockwood, G.J.; Normann, R.A.; Selph, M.M.; Williams, C.V.

    1999-01-01

    The Environmental Measurement-While-Drilling-Gamma Ray Spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides real-time environmental and drill bit data during drilling operations. The EMWD-GRS technology was demonstrated at Savannah River Site (SRS) F-Area Retention Basin. The EMWD-GRS technology demonstration consisted of continuously monitoring for gamma-radiation-producing contamination while drilling two horizontal boreholes below the backfilled waste retention basin. These boreholes passed near previously sampled locations where concentrations of contaminant levels of cesium had been measured. Contaminant levels continuously recorded by the EMWD-GRS system during drilling were compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples. The demonstration of the EMWD-GRS was a complete success. The results show general agreement between the soil sampling and EMWD-GRS techniques for CS-137. It was recognized that the EMWD-GRS tool would better satisfy our customers' needs if the instrument location could be continuously monitored. During the demonstration at SRS, an electromagnetic beacon with a walkover monitor (Subsitereg s ign) was used to measure bit location at depth. To use a beacon locator drilling must be stopped, thus it is normally only used when a new section of pipe was added. The location of contamination could only be estimated based on the position of the EMED-GRS package and the distance between locator beacon readings. A continuous location system that would allow us to know the location of each spectrum as it is obtained is needed

  6. Improvement an enterprises marketing performance measurement system

    Directory of Open Access Journals (Sweden)

    Stanković Ljiljana

    2013-01-01

    Full Text Available Business conditions in which modern enterprises do business are more and more complex. The complexity of the business environment is caused by activities of external and internal factors, which imposes the need for the turn in management focus. One of key turns is related to the need of adaptation and development of new business performance evaluation systems. The evaluation of marketing contribution to business performance is very important however a complex task as well. The marketing theory and practice indicates the need for developing adequate standards and systems for evaluating the efficiency of marketing decisions. The better understanding of marketing standards and ways that managers use is a very important factor that affects the efficiency of strategic decision-making. The paper presents the results of researching the way in which managers perceive and apply marketing performance measures. The data that were received through the field research sample enabled the consideration of the managers' attitudes on practical ways of implementing marketing performance measurement and identifying measures that managers imply as used mostly in business practice.

  7. Evaluation of protection measurements for urban environments

    International Nuclear Information System (INIS)

    Rochedo, Elaine R.R.; Wasserman, Maria Angelica V.

    2011-01-01

    Radioactive accidents has shown the necessity of a previous evaluation planning of exposure and directives for implementation of protection measurements. The description or measurements in the literature usually is associated to reduction of concentrations in the medium where they are applied. For verification the efficiency in dose reduction, it is necessary to proceed simulations. Through the development of data base on protection measurements, it was established basic sceneries, typically tropical as far the building type is concerned and the construction material. The program SIEM was used for simulation of contamination with 137 Cs. The results indicates that generic solutions persuade not to and the decision make processes should be effectuated according to the real conditions of contamination and the use of affected area. For affected areas, two classification criteria were defined: (1) efficiency in reducing the dose in the first year; and (2) efficiency in dose reducing at long term

  8. True mean rate measuring system

    International Nuclear Information System (INIS)

    Eichenlaub, D.P.

    1980-01-01

    A digital radiation-monitoring system for nuclear power plants uses digital and microprocessor circuitry to enable rapid processing of pulse information from remote radiation monitors. The pulse rates are analyzed to determine whether new pulse-rate information is statisticaly the same as that previously received and to determine the best possible averaging time, which can be changed so that the statistical error remains below a specified level while the system response time remains short. Several data modules each process the pulse-rate information from several remote radiation monitors. Each data module accepts pulse data from each radiation monitor and measures the true average or mean pulse rate of events occurring with a Poisson distribution to determine the radiation level. They then develop digital output signals which indciate the respective radiation levels and which can be transmitted via multiplexer circuits for additional processing and display. The data modules can accept signals from remote control stations or computer stations via the multiplexer circuit to change operating thresholds and alarm levels in their memories. A check module scans the various data modules to determine whether the output signals are valid. It also acts as a redundant data module and will automatically replace an inoperative unit. (DN)

  9. Lightning magnetic field measuring system in Bogota

    OpenAIRE

    Escobar Alvarado, Oscar Fernardo

    2013-01-01

    This thesis presents the configuration and performance of a lightning radiated electromagnetic field measuring system in Bogotá Colombia. The system is composed by both magnetic and electric field measuring systems working as separated sensors. The aim of the thesis is the design and construction of a Magnetic Field Measuring System and the implementation of a whole lightning measuring system in Bogotá. The theoretical background, design process, construction and implementation of the system ...

  10. Evaluation of saving measurements and energetic efficiency in air-conditioning systems; Evaluacion de medidas de ahorro y eficiencia energetica en sistemas de climatizacion

    Energy Technology Data Exchange (ETDEWEB)

    Perez Lombard, L [Asociacion de Investigacion y Cooperacion de Andalucia (Spain); Ortiz, J [Building Research Establishment (United Kingdom); Riviere, P [Armines-ecole des mines de Paris (France)

    2006-04-15

    Buildings require an adequate air conditioning to offer workers a labor environment where there is thermal comfort. A study was performed in three different European places which count on several climates. The conclusion was the following: in order to analyze the energy efficiency in edifications it is fundamental the simulation tools use with the purpose of calculating the consumption and evaluating the saving measurements. [Spanish] Los edificios requieren de una climatizacion adecuada para que los que ahi operan puedan hacerlo dentro de un ambiente laboral donde exista el confort termico. Se llevo a cabo un estudio en tres lugares de Europa poseedores de diferentes climas y se concluyo que para poder analizar la eficiencia energetica de climatizacion en las edificaciones es imprescindible el uso de herramientas de simulacion con el proposito de calcular el consumo y evaluar las medidas de ahorro.

  11. Evaluation of pain intensity measurement during the removal of wound dressing material using 'the PainVision™ system' for quantitative analysis of perception and pain sensation in healthy subjects.

    Science.gov (United States)

    Matsumura, Hajime; Imai, Ryutaro; Gondo, Masahide; Watanabe, Katsueki

    2012-08-01

    Reducing pain caused by the removal of adhesive wound dressing materials is very important in clinical practice and is also one of the factors to consider when choosing dressing materials. A visual analogue scale is the most popular method for assessing pain, but it is subjective and is difficult to evaluate quantitatively or statistically. Recently, a new method for the quantitative measurement of pain intensity using a painless electrical stimulation system, PainVision™, has been developed. In this study, we evaluated pain intensity during the removal of wound dressing materials in healthy volunteers by comparing pain during the removal of wound dressing materials, which use acrylic pressure-sensitive adhesive and pain during the removal of materials, which use soft silicone adhesive, as evaluated using the PainVision™ system. Pain intensity was significantly lower with the dressing materials, which use soft silicone adhesive when measured with the PainVision™ system. The PainVision™ system promises to be useful for the quantitative assessment of pain caused by the removal of adhesive wound dressing materials. Further studies are needed to determine whether the PainVision™ system is also effective in measuring pain caused by the removal of wound dressing materials in actual wounds. © 2012 The Authors. © 2012 Blackwell Publishing Ltd and Medicalhelplines.com Inc.

  12. Evaluation of indices for voltage stability monitoring using PMU measurements

    Directory of Open Access Journals (Sweden)

    Sindy Lorena Ramirez Perdomo

    2014-09-01

    Full Text Available Large disturbances such as voltage collapse and its consequences represent a large challenge to the operational safety of power systems. Therefore, it is important to have indicators of the presence of voltage stability problems in real time. Using phasor measure-ments of voltage and current that are presented in Phasor Measurement Units (PMU, indices for voltage stability monitoring can be calculated in real time. This paper presents some indices for voltage stability monitoring using PMU measurements. Evaluation of such indices on a simplified system was carried out, and the indices were classified according to their method of calculation. Finally, one of these indices was used with the New England 39-bus system under different operating scenarios, including load increments, line output and generator output, to check the indices’ behavior for voltage stability monitoring based on synchronized local measurements.

  13. Performance analysis and evaluation of direct phase measuring deflectometry

    Science.gov (United States)

    Zhao, Ping; Gao, Nan; Zhang, Zonghua; Gao, Feng; Jiang, Xiangqian

    2018-04-01

    Three-dimensional (3D) shape measurement of specular objects plays an important role in intelligent manufacturing applications. Phase measuring deflectometry (PMD)-based methods are widely used to obtain the 3D shapes of specular surfaces because they offer the advantages of a large dynamic range, high measurement accuracy, full-field and noncontact operation, and automatic data processing. To enable measurement of specular objects with discontinuous and/or isolated surfaces, a direct PMD (DPMD) method has been developed to build a direct relationship between phase and depth. In this paper, a new virtual measurement system is presented and is used to optimize the system parameters and evaluate the system's performance in DPMD applications. Four system parameters are analyzed to obtain accurate measurement results. Experiments are performed using simulated and actual data and the results confirm the effects of these four parameters on the measurement results. Researchers can therefore select suitable system parameters for actual DPMD (including PMD) measurement systems to obtain the 3D shapes of specular objects with high accuracy.

  14. Computerized x-ray radiographic system for fuel pellet measurements

    International Nuclear Information System (INIS)

    Green, D.R.; Karnesky, R.A.; Bromley, C.

    1977-01-01

    The development and operation of a computerized system for determination of fuel pellet diameters from x-ray radiography is described. Actual fuel pellet diameter measurements made with the system are compared to micrometer measurements on the same pellets, and statistically evaluated. The advantages and limitations of the system are discussed, and recommendations are made for further development

  15. Formation evaluation using measurements recorded while drilling

    International Nuclear Information System (INIS)

    Coope, D.F.; Hendricks, W.E.

    1984-01-01

    Two of the measurements recorded while drilling (MWD), gamma ray and resistivity, are traditionally formation evaluation measurements. However, their primary user thus far has been the drilling engineer. The authors believe that MWD will have increasing importance in formation evaluation, and that a good understanding of MWD resistivity and gamma ray logs will be needed by the log analyst. MWD gamma ray and resistivity logs are similar to their wireline counterparts, but there are significant differences. The differences stem from different invasion (or lack of invasion) development for MWD as opposed to open hole wireline; drill collar influence on both the resistivity and gamma ray (GR) measurements - this influence is both positive and negative; and logging speed (drilling rate for MWD) is much slower for MWD and can vary erratically. The MWD logs presented in this paper demonstrate the value of using MWD logs. Emphasis is placed on both the qualitative and quantitative techniques available to the log analyst to help him get maximum benefit from the MWD logs

  16. Approximate Bayesian evaluations of measurement uncertainty

    Science.gov (United States)

    Possolo, Antonio; Bodnar, Olha

    2018-04-01

    The Guide to the Expression of Uncertainty in Measurement (GUM) includes formulas that produce an estimate of a scalar output quantity that is a function of several input quantities, and an approximate evaluation of the associated standard uncertainty. This contribution presents approximate, Bayesian counterparts of those formulas for the case where the output quantity is a parameter of the joint probability distribution of the input quantities, also taking into account any information about the value of the output quantity available prior to measurement expressed in the form of a probability distribution on the set of possible values for the measurand. The approximate Bayesian estimates and uncertainty evaluations that we present have a long history and illustrious pedigree, and provide sufficiently accurate approximations in many applications, yet are very easy to implement in practice. Differently from exact Bayesian estimates, which involve either (analytical or numerical) integrations, or Markov Chain Monte Carlo sampling, the approximations that we describe involve only numerical optimization and simple algebra. Therefore, they make Bayesian methods widely accessible to metrologists. We illustrate the application of the proposed techniques in several instances of measurement: isotopic ratio of silver in a commercial silver nitrate; odds of cryptosporidiosis in AIDS patients; height of a manometer column; mass fraction of chromium in a reference material; and potential-difference in a Zener voltage standard.

  17. Reliability evaluation of power systems

    CERN Document Server

    Billinton, Roy

    1996-01-01

    The Second Edition of this well-received textbook presents over a decade of new research in power system reliability-while maintaining the general concept, structure, and style of the original volume. This edition features new chapters on the growing areas of Monte Carlo simulation and reliability economics. In addition, chapters cover the latest developments in techniques and their application to real problems. The text also explores the progress occurring in the structure, planning, and operation of real power systems due to changing ownership, regulation, and access. This work serves as a companion volume to Reliability Evaluation of Engineering Systems: Second Edition (1992).

  18. Computed radiography systems performance evaluation

    International Nuclear Information System (INIS)

    Xavier, Clarice C.; Nersissian, Denise Y.; Furquim, Tania A.C.

    2009-01-01

    The performance of a computed radiography system was evaluated, according to the AAPM Report No. 93. Evaluation tests proposed by the publication were performed, and the following nonconformities were found: imaging p/ate (lP) dark noise, which compromises the clinical image acquired using the IP; exposure indicator uncalibrated, which can cause underexposure to the IP; nonlinearity of the system response, which causes overexposure; resolution limit under the declared by the manufacturer and erasure thoroughness uncalibrated, impairing structures visualization; Moire pattern visualized at the grid response, and IP Throughput over the specified by the manufacturer. These non-conformities indicate that digital imaging systems' lack of calibration can cause an increase in dose in order that image prob/ems can be so/ved. (author)

  19. Evaluation of the sensitivity of electro-acoustic measurements for process monitoring and control of an atmospheric pressure plasma jet system

    Energy Technology Data Exchange (ETDEWEB)

    Law, V J [Dublin City University, National Centre of Plasma Science and Technology, Collins Avenue, Glasnevin, Dublin 9, Dublin (Ireland); O' Neill, F T; Dowling, D P, E-mail: vic.law@dcu.ie [School Mechanical and Materials Engineering, University College Dublin, Belfield, Dublin 4 (Ireland)

    2011-06-15

    The development of non-invasive process diagnostic techniques for the control of atmospheric plasmas is a critical issue for the wider adoption of this technology. This paper evaluates the use of a frequency-domain deconvolution of an electro-acoustic emission as a means to monitor and control the plasma formed using an atmospheric pressure plasma jet (APPJ) system. The air plasma system investigated was formed using a PlasmaTreat(TM) OpenAir applicator. Change was observed in the electro-acoustic signal with changes in substrate type (ceramic, steel, polymer). APPJ nozzle to substrate distance and substrate feature size were monitored. The decoding of the electro-acoustic emission yields three subdatasets that are described by three separate emission mechanisms. The three emissions are associated with the power supply fundamental drive frequency and its harmonics, the APPJ nozzle longitudinal mode acoustic emission and its odd overtones, and the acoustic surface reflection that is produced by the impedance mismatch between the discharge and the surface. Incorporating this knowledge into a LabVIEW program facilitated the continuous deconvolution of the electro-acoustic data. This enabled the use of specific frequency band test limits to control the APPJ treatment process which is sensitive to both plasma processing conditions and substrate type and features.

  20. Indicators System for Poverty Measurement

    Directory of Open Access Journals (Sweden)

    Constantin Mitrut

    2006-10-01

    Full Text Available Poverty represents a life aspect which is focusing the attention of both the macroeconomic analysis and the international comparisons. In order to measure the level being recorded by this phenomenon, there is a system of indicators which are used in order to underline, in a correlated manner, a number of aspects which are characterizing, quality and quantity wise, the evolution of the poverty in a specific country or, to a larger extent, through comparative surveys, at international level. Despite the fact that they are not the only instrument being used within the process of comparison of the stages of social and economic development at the international level, however the poverty indicators are providing a clear significance to the worked out surveys. In fact, the very purpose of the economic activity consists of increasing welfare and, as much as possible, at least reducing, if not eradicating, the poverty. The present work is broadly presenting the methodology as well as, both theoretical and practical, the way of computing the poverty, making a synthesis of the specific used indicators.

  1. Evaluation of protective measures for tropical environments

    International Nuclear Information System (INIS)

    Silva, D. N. G.; Rochedo, E. R. R.; Wasserman, M. A. V.; Conti, L. F. C.

    2012-01-01

    Nuclear and radiological accidents have demonstrated the need for prior planning for exposure assessment as well as guidelines for the implementation of protection and remediation measures of contaminated areas. Typically, the description of the efficiency of the measures in the literature is associated with the reduction of the concentration of the environmental media where they are applied. In order to verify the efficiency related to the reduction in doses, some basic scenarios were established, taking into account aspects of a typical tropical climate, such as building materials (urban areas) and types of crops and farming practices, considering the seasonality and soil type typical of the southeastern region of Brazil. The Integrated System for Emergency (SIEM) program was used to perform the simulations. The results indicate that decision-making processes must be made in accordance with the actual conditions of contamination and use of the affected area. For rural areas, the effectiveness of measures depends on many factors specific to each site, such as seasonality, produced crops, diet habits and degree of subsistence on the items in the diet, which make it unfeasible to develop generic predefined scenarios. The criteria for classification of measurements were defined as: (i) the efficiency in reducing the doses in the first year, in which largest dose rates are observed; (ii) the efficiency in reducing the long-term dose, considering 50 y for adults and (iii) the effect of delay in implementation of the measures on the reduction of doses. (authors)

  2. measurements by Thomson scattering system

    Indian Academy of Sciences (India)

    oirity in measuring the electron temperature (Te) and density (ne) in fusion plasma devices like tokamaks. ... by the plasma electrons is used for the measurements. .... will be in the photon integration mode and will be acquired by a computer.

  3. Plant operator performance evaluation system

    International Nuclear Information System (INIS)

    Ujita, Hiroshi; Fukuda, Mitsuko; Kubota, Ryuji.

    1989-01-01

    A plant operator performance evaluation system to analyze plant operation records during accident training and to identify and classify operator errors has been developed for the purpose of supporting realization of a training and education system for plant operators. A knowledge engineering technique was applied to evaluation of operator behavior by both even-based and symptom-based procedures, in various situations including event transition due to multiple failures or operational errors. The system classifies the identified errors as to their single and double types based on Swain's error classification and the error levels reflecting Rasmussen's cognitive level, and it also evaluates the effect of errors on plant state and then classifies error influence, using 'knowledge for phenomena and operations', as represented by frames. It has additional functions for analysis of error statistics and knowledge acquisition support of 'knowledge for operations'. The system was applied to a training analysis for a scram event in a BWR plant, and its error analysis function was confirmed to be effective by operational experts. (author)

  4. Evaluation and adjustment of description of denitrification in the DailyDayCent and COUP models based on N2 and N2O laboratory incubation system measurements

    Science.gov (United States)

    Grosz, Balázs; Well, Reinhard; Dannenmann, Michael; Dechow, René; Kitzler, Barbara; Michel, Kerstin; Reent Köster, Jan

    2017-04-01

    data-sets are needed in view of the extreme spatio-temporal heterogeneity of denitrification. DASIM will provide such data based on laboratory incubations including measurement of N2O and N2 fluxes and determination of the relevant drivers. Here, we present how we will use these data to evaluate common biogeochemical process models (DailyDayCent, Coup) with respect to modeled NO, N2O and N2 fluxes from denitrification. The models are used with different settings. The first approximation is the basic "factory" setting of the models. The next step would show the precision in the results of the modeling after adjusting the appropriate parameters from the result of the measurement values and the "factory" results. The better adjustment and the well-controlled input and output measured parameters could provide a better understanding of the probable scantiness of the tested models which will be a basis for future model improvement.

  5. Mobile measurement system for wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Kildemoes Moeller, T.

    1997-06-01

    The aim of this project `Udviklingsafproevning af smaa moellevinger` has been to develop a mobile measurement system for wind turbines. The following report describes the measurement system. The project has been financed by the Danish Ministry of Energy. (au)

  6. Dosimetric system for measurement of radioactive contaminations

    International Nuclear Information System (INIS)

    Litynski, Z.; Pienkos, J.P.; Witkowski, J.; Zadrozny, S.

    1985-01-01

    A dosimetric system for personnel dosimetry and monitoring measuring a contamination without time delay and dead time is described. The system ensures many-point measurement and minimalization of background radiation influence. 1 fig. (A.S.)

  7. Application in measurements of SKODA-OZES mobile measuring system

    International Nuclear Information System (INIS)

    Grof, V.; Drab, F.; Icha, K.

    A mobile digital measuring system was built at SKODA - Energeticke strojirenstvi based on digital information system CIS 3000 with the ADT 4100 computer. The system can operate in the BCS or in the RTE-C mode. Two programs are briefly described written for the purpose of measurements. The following applications of the system were tried: testing the reactivity meter on the reactor model, demonstration measurement of the temperature of the medium and display of values on the monitor, measurement of the temperature of the lid of the pressure vessel of the WWER-440 reactor during overlaying and measurement and the adaptive control of band thickness on a KVARTO 200 rolling mill. The measurement system is expected to be used in nuclear power plants and experimental reactors. (M.D.)

  8. Psychometric evaluation of the pediatric and parent-proxy Patient-Reported Outcomes Measurement Information System and the Neurology and Traumatic Brain Injury Quality of Life measurement item banks in pediatric traumatic brain injury.

    Science.gov (United States)

    Bertisch, Hilary; Rivara, Frederick P; Kisala, Pamela A; Wang, Jin; Yeates, Keith Owen; Durbin, Dennis; Zonfrillo, Mark R; Bell, Michael J; Temkin, Nancy; Tulsky, David S

    2017-07-01

    The primary objective is to provide evidence of convergent and discriminant validity for the pediatric and parent-proxy versions of the Patient-Reported Outcomes Measurement Information System (PROMIS) Anxiety, Depression, Anger, Peer Relations, Mobility, Pain Interference, and Fatigue item banks, the Neurology Quality of Life measurement system (Neuro-QOL) Cognition-General Concerns and Stigma item banks, and the Traumatic Brain Injury Quality of Life (TBI-QOL) Executive Function and Headache item banks in a pediatric traumatic brain injury (TBI) sample. Participants were 134 parent-child (ages 8-18 years) days. Children all sustained TBI and the dyads completed outcome ratings 6 months after injury at one of six medical centers across the United States. Ratings included PROMIS, Neuro-QOL, and TBI-QOL item banks, as well as the Pediatric Quality of Life inventory (PedsQL), the Health Behavior Inventory (HBI), and the Strengths and Difficulties Questionnaire (SDQ) as legacy criterion measures against which these item banks were validated. The PROMIS, Neuro-QOL, and TBI-QOL item banks demonstrated good convergent validity, as evidenced by moderate to strong correlations with comparable scales on the legacy measures. PROMIS, Neuro-QOL, and TBI-QOL item banks showed weaker correlations with ratings of unrelated constructs on legacy measures, providing evidence of discriminant validity. Our results indicate that the constructs measured by the PROMIS, Neuro-QOL, and TBI-QOL item banks are valid in our pediatric TBI sample and that it is appropriate to use these standardized scores for our primary study analyses.

  9. Gradual Reduction in Sodium Content in Cooked Ham, with Corresponding Change in Sensorial Properties Measured by Sensory Evaluation and a Multimodal Machine Vision System.

    Directory of Open Access Journals (Sweden)

    Kirsti Greiff

    Full Text Available The European diet today generally contains too much sodium (Na(+. A partial substitution of NaCl by KCl has shown to be a promising method for reducing sodium content. The aim of this work was to investigate the sensorial changes of cooked ham with reduced sodium content. Traditional sensorial evaluation and objective multimodal machine vision were used. The salt content in the hams was decreased from 3.4% to 1.4%, and 25% of the Na(+ was replaced by K(+. The salt reduction had highest influence on the sensory attributes salty taste, after taste, tenderness, hardness and color hue. The multimodal machine vision system showed changes in lightness, as a function of reduced salt content. Compared to the reference ham (3.4% salt, a replacement of Na(+-ions by K(+-ions of 25% gave no significant changes in WHC, moisture, pH, expressed moisture, the sensory profile attributes or the surface lightness and shininess. A further reduction of salt down to 1.7-1.4% salt, led to a decrease in WHC and an increase in expressible moisture.

  10. Gradual Reduction in Sodium Content in Cooked Ham, with Corresponding Change in Sensorial Properties Measured by Sensory Evaluation and a Multimodal Machine Vision System.

    Science.gov (United States)

    Greiff, Kirsti; Mathiassen, John Reidar; Misimi, Ekrem; Hersleth, Margrethe; Aursand, Ida G

    2015-01-01

    The European diet today generally contains too much sodium (Na(+)). A partial substitution of NaCl by KCl has shown to be a promising method for reducing sodium content. The aim of this work was to investigate the sensorial changes of cooked ham with reduced sodium content. Traditional sensorial evaluation and objective multimodal machine vision were used. The salt content in the hams was decreased from 3.4% to 1.4%, and 25% of the Na(+) was replaced by K(+). The salt reduction had highest influence on the sensory attributes salty taste, after taste, tenderness, hardness and color hue. The multimodal machine vision system showed changes in lightness, as a function of reduced salt content. Compared to the reference ham (3.4% salt), a replacement of Na(+)-ions by K(+)-ions of 25% gave no significant changes in WHC, moisture, pH, expressed moisture, the sensory profile attributes or the surface lightness and shininess. A further reduction of salt down to 1.7-1.4% salt, led to a decrease in WHC and an increase in expressible moisture.

  11. Brush seal performance measurement system

    OpenAIRE

    Aksoy, Serdar; Akşit, Mahmut Faruk; Aksit, Mahmut Faruk; Duran, Ertuğrul Tolga; Duran, Ertugrul Tolga

    2009-01-01

    Brush seals are rapidly replacing conventional labyrinth seals in turbomachinery applications. Upon pressure application, seal stiffness increases drastically due to frictional bristle interlocking. Operating stiffness is critical to determine seal wear life. Typically, seal stiffness is measured by pressing a curved shoe to brush bore. The static-unpressurized measurement is extrapolated to pressurized and high speed operating conditions. This work presents a seal stiffness measurement syste...

  12. High Pressure Electrolyzer System Evaluation

    Science.gov (United States)

    Prokopius, Kevin; Coloza, Anthony

    2010-01-01

    This report documents the continuing efforts to evaluate the operational state of a high pressure PEM based electrolyzer located at the NASA Glenn Research Center. This electrolyzer is a prototype system built by General Electric and refurbished by Hamilton Standard (now named Hamilton Sunstrand). It is capable of producing hydrogen and oxygen at an output pressure of 3000 psi. The electrolyzer has been in storage for a number of years. Evaluation and testing was performed to determine the state of the electrolyzer and provide an estimate of the cost for refurbishment. Pressure testing was performed using nitrogen gas through the oxygen ports to ascertain the status of the internal membranes and seals. It was determined that the integrity of the electrolyzer stack was good as there were no appreciable leaks in the membranes or seals within the stack. In addition to the integrity testing, an itemized list and part cost estimate was produced for the components of the electrolyzer system. An evaluation of the system s present state and an estimate of the cost to bring it back to operational status was also produced.

  13. Psychometric evaluation of the Patient-Reported Outcomes Measurement Information System (PROMIS) Nicotine Dependence Item Bank for use with electronic cigarettes.

    Science.gov (United States)

    Morean, Meghan; Krishnan-Sarin, Suchitra; Sussman, Steve; Foulds, Jonathan; Fishbein, Howard; Grana, Rachel; O'Malley, Stephanie S

    2018-01-02

    Psychometrically sound measures of e-cigarette dependence are lacking. We modified the PROMIS Nicotine Dependence Item Banks for use with e-cigarettes and evaluated the psychometrics of the 22-, 8- and 4-item adapted versions. 1009 adults who reported using e-cigarettes at least weekly completed an anonymous survey in Summer 2016 (50.2% male, 77.1% White, mean age 35.81 [10.71], 66.4% daily e-cigarette users, 72.6% current cigarette smokers). Psychometric analyses included confirmatory factor analysis, internal consistency, measurement invariance, examination of mean-level differences, convergent validity, and test-criterion relationships with e-cigarette use outcomes. All PROMIS-E versions had confirmable, internally consistent latent structures that were scalar invariant by sex, race, e-cigarette use (non-daily/daily), e-liquid nicotine content (no/yes), and current cigarette smoking status (no/yes). Daily e-cigarette users, nicotine e-liquid users, and cigarette smokers reported being more dependent on e-cigarettes than their counterparts. All PROMIS-E versions correlated strongly with one another, evidenced convergent validity with the Penn State E-cigarette Dependence Index and time to first e-cigarette use in the morning, and evidenced test-criterion relationships with vaping frequency, e-liquid nicotine concentration, and e-cigarette quit attempts. Similar results were observed when analyses were conducted within subsamples of exclusive e-cigarette users and duals-users of cigarettes and e-cigarettes. Each PROMIS-E version evidenced strong psychometric properties for assessing e-cigarette dependence in adults who either use e-cigarette exclusively or who are dual-users of cigarettes and e-cigarettes. However, results indicated little benefit of the longer versions over the 4-item PROMIS-E, which provides an efficient assessment of e-cigarette dependence. The availability of the novel, psychometrically sound PROMIS-E can further research on a wide range of

  14. Evaluation of Uranium-235 Measurement Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kaspar, Tiffany C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dibert, Mark W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-05-23

    Monolithic U-Mo fuel plates are rolled to final fuel element form from the original cast ingot, and thus any inhomogeneities in 235U distribution present in the cast ingot are maintained, and potentially exaggerated, in the final fuel foil. The tolerance for inhomogeneities in the 235U concentration in the final fuel element foil is very low. A near-real-time, nondestructive technique to evaluate the 235U distribution in the cast ingot is required in order to provide feedback to the casting process. Based on the technical analysis herein, gamma spectroscopy has been recommended to provide a near-real-time measure of the 235U distribution in U-Mo cast plates.

  15. A method for evaluating the effectiveness of site characterization measurements

    International Nuclear Information System (INIS)

    Ditmars, J.D.

    1987-01-01

    A quantitative approach for evaluating the effectiveness of site characterization measurement activities is developed and illustrated with an example application to hypothetical measurement schemes at a potential geologic repository site for radioactive waste. The method is a general one and could also be applied at sites for underground disposal of hazardous chemicals. The approach presumes that measurements will be undertaken to support predictions of the performance of some aspect of a constructed facility or natural system. It requires a quantitative performance objective, such as groundwater travel time or contaminant concentration, against which to compare predictions of performance. The approach recognizes that such predictions are uncertain because the measurements upon which they are based are uncertain. The effectiveness of measurement activities is quantified by a confidence index, β, that reflects the number of standard deviations separating the best estimate of performance from the predetermined performance objective. Measurements that reduce the uncertainty in predictions lead to increased values of β. 5 refs., 4 figs

  16. The diagnostic reliability of the quantitative pivot-shift evaluation using an electromagnetic measurement system for anterior cruciate ligament deficiency was superior to those of the accelerometer and iPad image analysis.

    Science.gov (United States)

    Tanaka, Toshikazu; Hoshino, Yuichi; Miyaji, Nobuaki; Ibaragi, Kazuyuki; Nishida, Kyohei; Nishizawa, Yuichiro; Araki, Daisuke; Kanzaki, Noriyuki; Matsushita, Takehiko; Kuroda, Ryosuke

    2017-10-14

    Several non-invasive devices have been developed to obtain quantitative assessment of the pivot-shift test in clinical setting using similar but diverse measurement parameters. However, the clinical usability of those measurements has yet to be closely investigated and compared. The purpose of this study was to compare the diagnostic accuracy of three non-invasive measurement devices for the pivot-shift test. Thirty patients with unilateral anterior cruciate ligament (ACL) injury were enrolled. The pivot-shift test was performed under general anaesthesia. Three devices, an accelerometer system (KiRA), an image analysis iPad application (iPad), and electromagnetic measurement system (EMS), were used simultaneously to provide two parameters, namely tibial acceleration monitored using KiRA and EMS, and tibial translation recorded using iPad and EMS. Side-to-side differences in each parameter and correlation between the measurements were tested, and a receiver-operating characteristic (ROC) curve analysis was conducted to compare their measurement accuracy. Significant side-to-side differences were successfully detected using any of the measurements (all p iPad and the EMS for the translation (r = 0.28; p iPad for tibial acceleration and translation, respectively. Although all three measurements were similarly capable of detecting ACL deficiency, the EMS has the advantage of comprehensive evaluation of the pivot-shift test by evaluating both tibial acceleration and translation with higher accuracy than those of KiRA and iPad. It could be suggested that any of those measurement tools might improve the clinical diagnosis of ACL insufficiency. Diagnostic study of consecutive patients with a universally applied gold standard, Level Ib.

  17. Fiber-optic voltage measuring system

    Science.gov (United States)

    Ye, Miaoyuan; Nie, De-Xin; Li, Yan; Peng, Yu; Lin, Qi-Qing; Wang, Jing-Gang

    1993-09-01

    A new fibre optic voltage measuring system has been developed based on the electrooptic effect of bismuth germanium oxide (Bi4Ge3O12)crystal. It uses the LED as the light source. The light beam emitted from the light source is transmitted to the sensor through the optic fibre and the intensity of the output beam is changed by the applied voltage. This optic signal is transmitted to the PIN detector and converted to an electric signal which is processed by the electronic circuit and 8098 single chip microcomputer the output voltage signal obtained is directly proportional to the applied voltage. This paper describes the principle the configuration and the performance parameters of the system. Test results are evaluated and discussed.

  18. Measuring stakeholder participation in evaluation: an empirical validation of the Participatory Evaluation Measurement Instrument (PEMI).

    Science.gov (United States)

    Daigneault, Pierre-Marc; Jacob, Steve; Tremblay, Joël

    2012-08-01

    Stakeholder participation is an important trend in the field of program evaluation. Although a few measurement instruments have been proposed, they either have not been empirically validated or do not cover the full content of the concept. This study consists of a first empirical validation of a measurement instrument that fully covers the content of participation, namely the Participatory Evaluation Measurement Instrument (PEMI). It specifically examines (1) the intercoder reliability of scores derived by two research assistants on published evaluation cases; (2) the convergence between the scores of coders and those of key respondents (i.e., authors); and (3) the convergence between the authors' scores on the PEMI and the Evaluation Involvement Scale (EIS). A purposive sample of 40 cases drawn from the evaluation literature was used to assess reliability. One author per case in this sample was then invited to participate in a survey; 25 fully usable questionnaires were received. Stakeholder participation was measured on nominal and ordinal scales. Cohen's κ, the intraclass correlation coefficient, and Spearman's ρ were used to assess reliability and convergence. Reliability results ranged from fair to excellent. Convergence between coders' and authors' scores ranged from poor to good. Scores derived from the PEMI and the EIS were moderately associated. Evidence from this study is strong in the case of intercoder reliability and ranges from weak to strong in the case of convergent validation. Globally, this suggests that the PEMI can produce scores that are both reliable and valid.

  19. HTGR Measurements and Instrumentation Systems

    International Nuclear Information System (INIS)

    Ball, Sydney J.; Holcomb, David Eugene; Cetiner, Mustafa Sacit

    2012-01-01

    This report provides an integrated overview of measurements and instrumentation for near-term future high-temperature gas-cooled reactors (HTGRs). Instrumentation technology has undergone revolutionary improvements since the last HTGR was constructed in the United States. This report briefly describes the measurement and communications needs of HTGRs for normal operations, maintenance and inspection, fuel fabrication, and accident response. The report includes a description of modern communications technologies and also provides a potential instrumentation communications architecture designed for deployment at an HTGR. A principal focus for the report is describing new and emerging measurement technologies with high potential to improve operations, maintenance, and accident response for the next generation of HTGRs, known as modular HTGRs, which are designed with passive safety features. Special focus is devoted toward describing the failure modes of the measurement technologies and assessing the technology maturity.

  20. Experimental evaluation of Arabic OCR systems

    Directory of Open Access Journals (Sweden)

    Mansoor Alghamdi

    2017-11-01

    Full Text Available Purpose – The aim of this paper is to experimentally evaluate the effectiveness of the state-of-the-art printed Arabic text recognition systems to determine open areas for future improvements. In addition, this paper proposes a standard protocol with a set of metrics for measuring the effectiveness of Arabic optical character recognition (OCR systems to assist researchers in comparing different Arabic OCR approaches. Design/methodology/approach – This paper describes an experiment to automatically evaluate four well-known Arabic OCR systems using a set of performance metrics. The evaluation experiment is conducted on a publicly available printed Arabic dataset comprising 240 text images with a variety of resolution levels, font types, font styles and font sizes. Findings – The experimental results show that the field of character recognition for printed Arabic still requires further research to reach an efficient text recognition method for Arabic script. Originality/value – To the best of the authors’ knowledge, this is the first work that provides a comprehensive automated evaluation of Arabic OCR systems with respect to the characteristics of Arabic script and, in addition, proposes an evaluation methodology that can be used as a benchmark by researchers and therefore will contribute significantly to the enhancement of the field of Arabic script recognition.

  1. Management information systems software evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Al-Tunisi, N.; Ghazzawi, A.; Gruyaert, F.; Clarke, D. [Saudi Aramco, Dhahran (Saudi Arabia). Process and Control Systems Dept.

    1995-11-01

    In November 1993, Saudi Aramco management endorsed a proposal to coordinate the development of the Management Information Systems (MISs) of four concurrent projects for its facilities Controls Modernization Program. The affected projects were the Ras Tanura Refinery Upgrade Project, the Abqaiq Plant Controls Modernization and the Shedgum and Uthmaniyah Gas plants Control Upgrade Projects. All of these projects had a significant requirement of MISs in their scope. Under the leadership of the Process and Control Systems Department, and MIS Coordination Team was formed with representatives of several departments. An MIS Applications Evaluation procedure was developed based on the Kepner Tregoe Decisions Analysis Process and general questionnaires were sent to over a hundred potential Vendors. The applications were divided into several categories, such as: Data Capture and Historization, Human User Interface, Trending, Reporting, Graphic Displays, Data Reconciliation, Statistical Analysis, Expert Systems, Maintenance Applications, Document Management and Operations Planning and Scheduling. For each of the MIS Application areas, detailed follow-up questionnaires were used to short list the candidate products. In May and June 1994, selected Vendors were invited to Saudi Arabia for an Exhibition which was open to all Saudi Aramco employees. In conjunction with this, the Vendors were subjected to a rigorous product testing exercise by independent teams of testers. The paper will describe the methods used and the lessons learned in this extensive software evaluation phase, which was a first for Saudi Aramco.

  2. Management information systems software evaluation

    International Nuclear Information System (INIS)

    Al-Tunisi, N.; Ghazzawi, A.; Gruyaert, F.; Clarke, D.

    1995-01-01

    In November 1993, Saudi Aramco management endorsed a proposal to coordinate the development of the Management Information Systems (MISs) of four concurrent projects for its facilities Controls Modernization Program. The affected projects were the Ras Tanura Refinery Upgrade Project, the Abqaiq Plant Controls Modernization and the Shedgum and Uthmaniyah Gas plants Control Upgrade Projects. All of these projects had a significant requirement of MISs in their scope. Under the leadership of the Process and Control Systems Department, and MIS Coordination Team was formed with representatives of several departments. An MIS Applications Evaluation procedure was developed based on the Kepner Tregoe Decisions Analysis Process and general questionnaires were sent to over a hundred potential Vendors. The applications were divided into several categories, such as: Data Capture and Historization, Human User Interface, Trending, Reporting, Graphic Displays, Data Reconciliation, Statistical Analysis, Expert Systems, Maintenance Applications, Document Management and Operations Planning and Scheduling. For each of the MIS Application areas, detailed follow-up questionnaires were used to short list the candidate products. In May and June 1994, selected Vendors were invited to Saudi Arabia for an Exhibition which was open to all Saudi Aramco employees. In conjunction with this, the Vendors were subjected to a rigorous product testing exercise by independent teams of testers. The paper will describe the methods used and the lessons learned in this extensive software evaluation phase, which was a first for Saudi Aramco

  3. Parametric modelling of cardiac system multiple measurement signals: an open-source computer framework for performance evaluation of ECG, PCG and ABP event detectors.

    Science.gov (United States)

    Homaeinezhad, M R; Sabetian, P; Feizollahi, A; Ghaffari, A; Rahmani, R

    2012-02-01

    The major focus of this study is to present a performance accuracy assessment framework based on mathematical modelling of cardiac system multiple measurement signals. Three mathematical algebraic subroutines with simple structural functions for synthetic generation of the synchronously triggered electrocardiogram (ECG), phonocardiogram (PCG) and arterial blood pressure (ABP) signals are described. In the case of ECG signals, normal and abnormal PQRST cycles in complicated conditions such as fascicular ventricular tachycardia, rate dependent conduction block and acute Q-wave infarctions of inferior and anterolateral walls can be simulated. Also, continuous ABP waveform with corresponding individual events such as systolic, diastolic and dicrotic pressures with normal or abnormal morphologies can be generated by another part of the model. In addition, the mathematical synthetic PCG framework is able to generate the S4-S1-S2-S3 cycles in normal and in cardiac disorder conditions such as stenosis, insufficiency, regurgitation and gallop. In the PCG model, the amplitude and frequency content (5-700 Hz) of each sound and variation patterns can be specified. The three proposed models were implemented to generate artificial signals with varies abnormality types and signal-to-noise ratios (SNR), for quantitative detection-delineation performance assessment of several ECG, PCG and ABP individual event detectors designed based on the Hilbert transform, discrete wavelet transform, geometric features such as area curve length (ACLM), the multiple higher order moments (MHOM) metric, and the principal components analysed geometric index (PCAGI). For each method the detection-delineation operating characteristics were obtained automatically in terms of sensitivity, positive predictivity and delineation (segmentation) error rms and checked by the cardiologist. The Matlab m-file script of the synthetic ECG, ABP and PCG signal generators are available in the Appendix.

  4. Integrated system for seismic evaluations

    International Nuclear Information System (INIS)

    Xu, J.; Philippacopoulos, A.J.; Miller, C.A.; Costantino, C.J.; Graves, H.

    1989-01-01

    This paper describes the various features of the Seismic Module of the CARES system (Computer Analysis for Rapid Evaluation of Structures). This system was developed by Brookhaven National Laboratory (BNL) for the US Nuclear Regulatory Commission to perform rapid evaluations of structural behavior and capability of nuclear power plant facilities. The CARES is structured in a modular format. Each module performs a specific type of analysis i.e., static or dynamic, linear or nonlinear, etc. This paper describes the features of the Seismic Module in particular. The development of the Seismic Module of the CARES system is based on an approach which incorporates all major aspects of seismic analysis currently employed by the industry into an integrated system that allows for carrying out interactively computations of structural response to seismic motions. The code operates on a PC computer system and has multi-graphics capabilities. It has been designed with user friendly features and it allows for interactive manipulation of various analysis phases during the seismic design process. The capabilities of the seismic module include (a) generation of artificial time histories compatible with given design ground response spectra, (b) development of Power Spectral Density (PSD) functions associated with the seismic input, (c) deconvolution analysis using vertically propagating shear waves through a given soil profile, and (d) development of in-structure response spectra or corresponding PSD's. It should be pointed out that these types of analyses can also be performed individually by using available computer codes such as FLUSH, SAP, etc. The uniqueness of the CARES, however, lies on its ability to perform all required phases of the seismic analysis in an integrated manner. 5 refs., 6 figs

  5. Measurement system performance during cold checkout runs at the BNFP

    International Nuclear Information System (INIS)

    Ehinger, M.H.; Crawford, J.M.

    1978-01-01

    The measurement systems in a complex nuclear fuel plant such as the Barnwell Nuclear Fuel Plant rely on capabilities to remotely measure solution quantities and determine the nuclear material content of these solutions. During recent testing activities using natural uranium, a major objective of the NMC group was to demonstrate these solution measurement capabilities. Installed measurement systems at the BNFP use the most recent innovations in measurement equipment and techniques for remote solution measurement. This paper presents the measurement methods and results of the tests and evaluations. 6 figures

  6. Introduction to control system performance measurements

    CERN Document Server

    Garner, K C

    1968-01-01

    Introduction to Control System Performance Measurements presents the methods of dynamic measurements, specifically as they apply to control system and component testing. This book provides an introduction to the concepts of statistical measurement methods.Organized into nine chapters, this book begins with an overview of the applications of automatic control systems that pervade almost every area of activity ranging from servomechanisms to electrical power distribution networks. This text then discusses the common measurement transducer functions. Other chapters consider the basic wave

  7. Evaluation of the COGITO system

    DEFF Research Database (Denmark)

    Andersen, V.; Andersen, H.H.K.

    2002-01-01

    -site and for benefiting efficiently from the functionality of the site. In order to make the report a stand-alone report, it contains an introduction including 'Study of end-user needs and behaviour' exposing problemsconcerning e-commerce in general (taken from the D6.1), and a brief review of the objectives......This report covers the deliverable D7.2 of the COGITO project. It presents the evaluation of an 'intelligent' agent integrated into an e-commerce system. The aim of the agent is to support the user partly through direct communication and partly by guidinghim/her for navigating the web...

  8. Radiation transmission pipe thickness measurement system

    International Nuclear Information System (INIS)

    Higashi, Yasuhiko

    2010-01-01

    Fuji Electric Systems can be measured from the outer insulation of the transmission Characteristics and radiation detection equipment had been developed that can measure pipe wall thinning in plant and running, the recruitment of another three-beam calculation method by pipe thickness measurement system was developed to measure the thickness of the pipe side. This equipment has been possible to measure the thickness of the circumferential profile of the pipe attachment by adopting automatic rotation. (author)

  9. SQUID-based measuring systems

    Indian Academy of Sciences (India)

    field produced by a given two-dimensional current density distribution is inverted using the Fourier transform technique. Keywords ... Superconducting quantum interference devices (SQUIDs) are the most sensitive detectors for measurement of ... omagnetic prospecting, detection of gravity waves etc. Judging the importance ...

  10. Efficiency Evaluation of Energy Systems

    CERN Document Server

    Kanoğlu, Mehmet; Dinçer, İbrahim

    2012-01-01

    Efficiency is one of the most frequently used terms in thermodynamics, and it indicates how well an energy conversion or process is accomplished. Efficiency is also one of the most frequently misused terms in thermodynamics and is often a source of misunderstanding. This is because efficiency is often used without being properly defined first. This book intends to provide a comprehensive evaluation of various efficiencies used for energy transfer and conversion systems including steady-flow energy devices (turbines, compressors, pumps, nozzles, heat exchangers, etc.), various power plants, cogeneration plants, and refrigeration systems. The book will cover first-law (energy based) and second-law (exergy based) efficiencies and provide a comprehensive understanding of their implications. It will help minimize the widespread misuse of efficiencies among students and researchers in energy field by using an intuitive and unified approach for defining efficiencies. The book will be particularly useful for a clear ...

  11. Absolute calibration in vivo measurement systems

    International Nuclear Information System (INIS)

    Kruchten, D.A.; Hickman, D.P.

    1991-02-01

    Lawrence Livermore National Laboratory (LLNL) is currently investigating a new method for obtaining absolute calibration factors for radiation measurement systems used to measure internally deposited radionuclides in vivo. Absolute calibration of in vivo measurement systems will eliminate the need to generate a series of human surrogate structures (i.e., phantoms) for calibrating in vivo measurement systems. The absolute calibration of in vivo measurement systems utilizes magnetic resonance imaging (MRI) to define physiological structure, size, and composition. The MRI image provides a digitized representation of the physiological structure, which allows for any mathematical distribution of radionuclides within the body. Using Monte Carlo transport codes, the emission spectrum from the body is predicted. The in vivo measurement equipment is calibrated using the Monte Carlo code and adjusting for the intrinsic properties of the detection system. The calibration factors are verified using measurements of existing phantoms and previously obtained measurements of human volunteers. 8 refs

  12. Measuring and evaluating energy consumption in street lighting networks

    International Nuclear Information System (INIS)

    Janiga, P.; Gasparovsky, D.

    2012-01-01

    Smart metering and smart grid are incoming technologies that provide new opportunities in various fields. In connection with the issue of evaluation of the energy aspects of public lighting networks opens up the possibility of evaluating and measuring consumption. Based on the obtained values would be possible to determine energy consumption of lighting systems. This obtained value could serve as a basis for comparing the relevant networks and thus the optimality assessment of lighting designs. Currently, the measure placed in the switchboard of public lighting. If we have considered sections parametramim same lighting, it is necessary to obtain more value from the measured or determined to assess the consumption of time. Proposal of such methods is still under construction but the basic methods have already been outlined. (Authors)

  13. Quality control of gamma radiation measuring systems

    International Nuclear Information System (INIS)

    Surma, M.J.

    2002-01-01

    The problem of quality control and assurance of gamma radiation measuring systems has been described in detail. The factors deciding of high quality of radiometric measurements as well as statistical testing and calibration of measuring systems have been presented and discussed

  14. Identification of invariant measures of interacting systems

    International Nuclear Information System (INIS)

    Chen Jinwen

    2004-01-01

    In this paper we provide an approach for identifying certain mixture representations of some invariant measures of interacting stochastic systems. This is related to the problem of ergodicity of certain extremal invariant measures that are translation invariant. Corresponding to these, results concerning the existence of invariant measures and certain weak convergence of the systems are also provided

  15. An automatic tension measurement system of MWPC wires

    International Nuclear Information System (INIS)

    D'Antone, I.; Lolli, M.; Torromeo, G.

    1992-01-01

    An electronic system is presented for automatic mechanical tension measurement to test wire chambers. The developed system works in the tension range from 50 g to 300 g; this large working range is obtained by using a microcontroller that performs a digital control on the bridge of an oscillator containing the wire of which the tension has to be measured. The microcontroller automatically brings the system towards the oscillation condition and subsequently, measuring the frequency, it evaluates, displays and sends to a host computer the value of the mechanical tension of the wires. The system is precise and allows fast measurements. A description of the hardware and software design is given. (orig.)

  16. Evaluation of a radioactive aerosol surveillance system

    International Nuclear Information System (INIS)

    Scripsick, R.C.; Stafford, R.G.; Beckman, R.J.; Tillery, M.I.; Romero, P.O.

    Measurements of the dilution of air contaminants between worker breathing zone and area air samplers were made by releasing a test aerosol in a workroom equipped with an aerosol surveillance system. The data were used to evaluate performance, and suggest improvements in design of the workroom's alarming air monitor system. It was found that a breathing zone concentration of 960 times the maximum permissible concentration in air (MPC/sub a/) for a half-hour was required to trigger alarms of the existing monitoring system under some release conditions. Alternative air monitor placement, suggested from dilution measurements, would reduce this average triggering concentration to 354 MPC/sub a/. Deployment of additional air monitors could further reduce the average triggering concentration to 241 MPC/sub a/. The relation between number of monitors and triggering concentration was studied. No significant decrease in average triggering concentration was noted for arrays containing greater than five monitors

  17. Management Control Systems, Evaluative Style, and Behaviour : Exploring the Concept and Behavioural Consequences of Evaluative Style

    NARCIS (Netherlands)

    J. Noeverman (Jan)

    2007-01-01

    textabstractOrganisations develop and implement performance measurement and performance evaluation systems to motivate employees to take actions that -in the end- improve organisational (financial) performance. But do these systems really influence employee behaviour as intended? This thesis shows

  18. Measurement system as a subsystem of the quality management system

    OpenAIRE

    Ľubica Floreková; Ján Terpák; Marcela Čarnogurská

    2006-01-01

    Each measurement system and a control principle must be based on certain facts about the system behaviour (what), operation (how) and structure (why). Each system is distributed into subsystems that provide an input for the next subsystem. For each system, start is important the begin, that means system characteristics, collecting of data, its hierarchy and the processes distribution.A measurement system (based on the chapter 8 of the standard ISO 9001:2000 Quality management system, requirem...

  19. Measuring situation awareness in complex systems: Comparison of measures study

    OpenAIRE

    Salmon, PM; Stanton, NA; Walker, GH; Jenkins, DP; Ladva, D; Rafferty, L; Young, MS

    2008-01-01

    Situation Awareness (SA) is a distinct critical commodity for teams working in complex industrial systems and its measurement is a key provision in system, procedural and training design efforts. This article describes a study that was undertaken in order to compare three different SA measures (a freeze probe recall approach, a post trial subjective rating approach and a critical incident interview technique) when used to assess participant SA during a military planning task. The results indi...

  20. Particle measurement systems and methods

    Science.gov (United States)

    Steele, Paul T [Livermore, CA

    2011-10-04

    A system according to one embodiment includes a light source for generating light fringes; a sampling mechanism for directing a particle through the light fringes; and at least one light detector for detecting light scattered by the particle as the particle passes through the light fringes. A method according to one embodiment includes generating light fringes using a light source; directing a particle through the light fringes; and detecting light scattered by the particle as the particle passes through the light fringes using at least one light detector.

  1. International Clean Energy System Using Hydrogen Conversion (WE-NET). subtask 3. Conceptual design of the total system (safety measures and evaluation technology); Suiso riyo kokusai clean energy system gijutsu (WE-NET). subtask 3. Zentai system gainen sekkei (anzen taisaku hyoka gijutsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    Safety measures and assessment technology were studied for the WE-NET project. As the study result in fiscal 1996, the information on safety design, anomaly and accident was collected and arranged. The information on safety measures, ideology and criterion was also collected by visiting some domestic and overseas organizations experienced about handling of liquid hydrogen (LH). The initial survey was made for the safety design ideology, analytical technique and disaster preventive measures of LNG systems as the similar cold liquid system. Accidents and explosion accident of a hydrogen production plant (water electrolysis) in Germany were analyzed. Events on storage tanks and leakage around the tanks were studied as typical risk of LH considering temporary and LNG system design information. The model based on the LH spillage test result and 3-D dispersion of vapor cloud were prepared by modifying a simulation code. The model allowed evaluation of the effect of explosion and fire accidents of compressed hydrogen gas and flying fragments on structures and people, and visual display of distances from a tank and damage conditions. 19 refs., 29 figs., 18 tabs.

  2. Traffic Management Systems Performance Measurement: Final Report

    OpenAIRE

    Banks, James H.; Kelly, Gregory

    1997-01-01

    This report documents a study of performance measurement for Transportation Management Centers (TMCs). Performance measurement requirements were analyzed, data collection and management techniques were investigated, and case study traffic data system improvement plans were prepared for two Caltrans districts.

  3. Evaluation of caries progression in dentin treated by fluoride-containing materials using an in-air micro-PIGE and micro-PIXE measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, H., E-mail: yhiroko@dent.osaka-u.ac.jp [Department of Restorative Dentistry and Endodontology, Osaka University Graduate School of Dentistry, 1-8 Yamada-Oka, Suita 565-0871 (Japan); Iwami, Y.; Yagi, K.; Hayashi, M. [Department of Restorative Dentistry and Endodontology, Osaka University Graduate School of Dentistry, 1-8 Yamada-Oka, Suita 565-0871 (Japan); Komatsu, H.; Okuyama, K.; Matsuda, Y. [Graduate School of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Kita-ku, Sapporo 060-8586 (Japan); Yasuda, K. [The Wakasa Wan Energy Research Center, 64-52-1 Nagatani, Tsuruga 914-0192 (Japan)

    2015-04-01

    It is well-known that fluorine (F) is involved in the progression of caries. The evaluation of caries progression has conventionally been based on the change in mineral content using transverse microradiography (TMR). The purpose of this study was to evaluate the progression of dentinal caries by the change in calcium (Ca) content using Particle-Induced Gamma-ray Emission/Particle-Induced X-ray Emission (PIGE/PIXE) techniques at the Wakasa Wan Energy Research Center. We also assessed the relationship between caries progression rate and the concentration of F penetration into dentin from dental fluoride-containing materials (FCMs). Dentin sections of six extracted human teeth were prepared to obtain various amounts of F uptake using three types of FCMs. F and Ca distribution of specimens were obtained using PIGE/PIXE techniques. After evaluation, the specimens were immersed in 10 ml of demineralizing solution (pH 4.5) to simulate caries attack. To estimate caries progression rates, the same portions of the specimens were evaluated after caries attack treatment using PIGE/PIXE. A negative correlation between the F uptake in dentin and the rate of caries progression was observed. Therefore, caries progression in dentin was reduced by increasing the amount of F uptake from FCMs. This demonstrates that PIGE/PIXE techniques are valuable for estimating caries progression rates.

  4. Evaluation of caries progression in dentin treated by fluoride-containing materials using an in-air micro-PIGE and micro-PIXE measurement system

    International Nuclear Information System (INIS)

    Yamamoto, H.; Iwami, Y.; Yagi, K.; Hayashi, M.; Komatsu, H.; Okuyama, K.; Matsuda, Y.; Yasuda, K.

    2015-01-01

    It is well-known that fluorine (F) is involved in the progression of caries. The evaluation of caries progression has conventionally been based on the change in mineral content using transverse microradiography (TMR). The purpose of this study was to evaluate the progression of dentinal caries by the change in calcium (Ca) content using Particle-Induced Gamma-ray Emission/Particle-Induced X-ray Emission (PIGE/PIXE) techniques at the Wakasa Wan Energy Research Center. We also assessed the relationship between caries progression rate and the concentration of F penetration into dentin from dental fluoride-containing materials (FCMs). Dentin sections of six extracted human teeth were prepared to obtain various amounts of F uptake using three types of FCMs. F and Ca distribution of specimens were obtained using PIGE/PIXE techniques. After evaluation, the specimens were immersed in 10 ml of demineralizing solution (pH 4.5) to simulate caries attack. To estimate caries progression rates, the same portions of the specimens were evaluated after caries attack treatment using PIGE/PIXE. A negative correlation between the F uptake in dentin and the rate of caries progression was observed. Therefore, caries progression in dentin was reduced by increasing the amount of F uptake from FCMs. This demonstrates that PIGE/PIXE techniques are valuable for estimating caries progression rates

  5. New measuring and protection system at VR-1 training reactor

    International Nuclear Information System (INIS)

    Kropik, M.; Jurickova, M.

    2006-01-01

    The contribution describes the new measuring and protection system of the VR-1 training reactor. The measuring and protection system upgrade is an integral part of the reactor I and C upgrade. The new measuring and protection system of the VR-1 reactor consists of the operational power measuring and the independent power protection systems. Both systems measure the reactor power and power rate, initiate safety action if safety limits are exceeded and send data (power, power rate, status, etc.) to the reactor control system. The operational power measuring system is a full power range system that receives signal from a fission chamber. The signal is evaluated according to the reactor power either in the pulse or current mode. The current mode utilizes the DC current and Campbell techniques. The new independent power protection system operates in the two highest reactor power decades. It receives signals from a boron chamber and evaluates it in the pulse mode. Both systems are computer based. The operational power measuring and independent power protection systems are diverse - different types and location of chambers, completely different hardware, software algorithms for the power and power rate calculations, software development tools and teems for the software manufacturing. (author)

  6. Using a New Measurement to Evaluate Pain Relief Among Cancer Inpatients with Clinically Significant Pain Based on a Nursing Information System: A Three-Year Hospital-Based Study.

    Science.gov (United States)

    Wang, Wei-Yun; Chu, Chi-Ming; Sung, Chun-Sung; Ho, Shung-Tai; Wu, Yi-Syuan; Liang, Chun-Yu; Wang, Kwua-Yun

    2016-11-01

    Developing a new measurement index is the first step in evaluating pain relief outcomes. Although the percentage difference in pain intensity (%PID) is the most popular indicator, this indicator does not take into account the goal of pain relief. Therefore, the aims of this study were to develop a pain relief index (PRI) for outcome evaluation and to examine the index using demographic characteristics of cancer inpatients with clinically significant pain. Retrospective cohort study. A national hospital. All cancer inpatients. Pain intensity was assessed using a numerical rating scale, a faces pain scale or the Face, Legs, Activity, Cry, Consolability (FLACC) Behavioral Tool. Using a nursing information system, a pain score database containing data from 2011 through 2013 was analyzed. Cancer patients representing 93,812 hospitalizations were considered in this study. We focused on cancer patients for whom the worst pain intensity (WPI) was ≥ 4 points. PRI values of -62.02% to -72.55% were observed in the WPI ≥ 7 and 4 ≤ WPI ≤ 6 groups. Significant (P 65 years old, those who were admitted to the medicine or gynecology and those who had a hospital stay > 30 days. This hospital-based study demonstrated that the PRI is an effective and valid measure for evaluating outcome data using an electronic nursing information system. We will further define the meaningful range of percentage difference in PRI from various perspectives. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Evaluation of hypostasis using a colorimeter measuring system and its application to assessment of the post-mortem interval (time of death).

    Science.gov (United States)

    Vanezis, P; Trujillo, O

    1996-03-05

    Hypostasis was measured in 93 cadavers using a tristimulus colorimeter in order to investigate its relationship with the time of death. The intensity (lightness) of the hypostasis in each case was measured over a period of 4 h and the rate of change in lightness derived. When examined against the time of death, it was found that there was a good correlation between the two. Namely, that the rate of change of lightness (and it can be inferred that this represents displaceability) decreases as the post-mortem period increases. The shift in hypostasis was particularly marked in the first 12 h and decreased thereafter. However, hypostasis could be useful for time of death estimation for up to 48 h. After this time, the degree of change was small or non-existent and by 72 h hypostasis had become fixed in the majority of cases, within our measuring period of 4 h.

  8. Burnup verification using the FORK measurement system

    International Nuclear Information System (INIS)

    Ewing, R.I.

    1994-01-01

    Verification measurements may be used to help ensure nuclear criticality safety when burnup credit is applied to spent fuel transport and storage systems. The FORK measurement system, designed at Los Alamos National Laboratory for the International Atomic Energy Agency safeguards program, has been used to verify reactor site records for burnup and cooling time for many years. The FORK system measures the passive neutron and gamma-ray emission from spent fuel assemblies while in the storage pool. This report deals with the application of the FORK system to burnup credit operations based on measurements performed on spent fuel assemblies at the Oconee Nuclear Station of Duke Power Company

  9. Farm nitrogen balances in six European agricultural landscapes – a method for farming system assessment, emission hotspot identification, and mitigation measure evaluation

    DEFF Research Database (Denmark)

    Dalgaard, Tommy; Bienkowski, J.; Bleeker, A.

    2012-01-01

    average was similar to those of PL and DK (122 ± 20 and 146 ± 55 kg N ha−1yr−1, respectively) when landless poultry were included. However, the challenge remains how to account for indirect N surpluses and emissions from such farms with a large export of manure out of the landscape. We conclude that farm......–2009. This indicates that farm N surpluses may be used as an independent dataset for validation of measured and modelled N emissions in agricultural landscapes. However, no significant correlation was found to N measured in surface waters, probably because of the short time horizon of the study. A case study...

  10. Site evaluation using measured meteorology data

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R. E.; Rusche, B. C. [Savannah River Lab., E.I. du Pont de Nemours and Co., Aiken, South Carolina (United States)

    1967-07-01

    A key factor in reactor site evaluation is the frequency of occurrence of various dispersion conditions and this relationship to potential off-site doses following a reactor accident. Detailed measurements of the wind speed, wind direction, and temperature at heights up to 1200 ft at the Savannah River Plant form the basis for a comprehensive analysis of the frequency of occurrence of potential off-site doses. A complete set of data was taken about every five minutes, and 107,000 sets (about one year of data) were analyzed. The meteorology data were converted to ordinary dispersion parameters through correlating equations developed at Brookhaven National Laboratory. The results were expressed on curves in dose per unit release of activity vs distance from the reactor with probability of occurrence as a parameter. Separate sets of curves were calculated for releases of noble gas and of halogens and at release heights of 200 ft (a nominal stack height) and of 850 ft (about the height of the tallest power plant stacks). Additional curves were developed to show dose as a function of direction and probability of occurrence. In addition to the dose frequency distribution analyses performed as a function of height of release, direction, and distance; more conventional frequency distributions of wind speed, wind direction, and thermal stability were developed as a function of height. All the analyses were carried out on the IBM 360/65. These results represent the first known analysis utilizing data up to 1200 ft and taken often enough to develop reliable frequency distributions for a short term release. (author)

  11. Heart Rate Measures of Flight Test and Evaluation

    National Research Council Canada - National Science Library

    Bonner, Malcolm A; Wilson, Glenn F

    2001-01-01

    .... Because flying is a complex task, several measures are required to derive the best evaluation. This article describes the use of heart rate to augment the typical performance and subjective measures used in test and evaluation...

  12. Acid dew point measurements in combustion gases using the dew point measuring system AH 85100

    Energy Technology Data Exchange (ETDEWEB)

    Fehler, D.

    1984-01-01

    Measuring system for continuous monitoring of the SO/sub 2//SO/sub 3/ dew point in the flue gas, characterized by a low failure rate, applicability inside the flue gas duct, maintenance-free continuous operation, and self-cleaning. The measuring principle is the cooling of the sensor element down to the 'onset condensation' message. Sensor surface temperatures are listed and evaluated as flue gas dew point temperatures. The measuring system is described. (DOMA).

  13. A shielded measurement system for irradiated nuclear fuel measurements

    International Nuclear Information System (INIS)

    Mosby, W.R.; Aumeier, S.E.; Klann, R.T.

    1999-01-01

    The US Department of Energy (DOE) is driving a transition toward dry storage of irradiated nuclear fuel (INF), toward characterization of INF for final disposition, and toward resumption of measurement-based material control and accountability (MC and A) efforts for INF. For these reasons, the ability to efficiently acquire radiological measurements of INF in a dry environment is important. The DOE has recently developed a guidance document proposing MC and A requirements for INF. The intent of this document is to encourage the direct measurement of INF on inventory within DOE. The guidance document reinforces and clarifies existing material safeguards requirements as they pertain to INF. Validation of nuclear material contents of non-self-protecting INF must be accomplished by direct measurement, application of validated burnup codes using qualified initial fissile content, burnup data, and age or by other valid means. The fuel units must remain intact with readable identification numbers. INF may be subject to periodic inventories with visual item accountability checks. Quantitative measurements may provide greater assurance of the integrity of INF inventories at a lower cost and with less personnel exposure than visual item accountability checks. Currently, several different approaches are used to measure the radiological attributes of INF. Although these systems are useful for a wide variety of applications, there is currently no relatively inexpensive measurement system that is readily deployable for INF measurements for materials located in dry storage. The authors present the conceptual design of a shielded measurement system (SMS) that could be used for this purpose. The SMS consists of a shielded enclosure designed to house a collection of measurement systems to allow measurements on spent fuel outside of a hot cell. The phase 1 SMS will contain 3 He detectors and ionization chambers to allow for gross neutron and gamma-ray measurements. The phase 2 SMS

  14. GPS synchronized power system phase angle measurements

    Science.gov (United States)

    Wilson, Robert E.; Sterlina, Patrick S.

    1994-09-01

    This paper discusses the use of Global Positioning System (GPS) synchronized equipment for the measurement and analysis of key power system quantities. Two GPS synchronized phasor measurement units (PMU) were installed before testing. It was indicated that PMUs recorded the dynamic response of the power system phase angles when the northern California power grid was excited by the artificial short circuits. Power system planning engineers perform detailed computer generated simulations of the dynamic response of the power system to naturally occurring short circuits. The computer simulations use models of transmission lines, transformers, circuit breakers, and other high voltage components. This work will compare computer simulations of the same event with field measurement.

  15. Operational Contract Support: Economic Impact Evaluation and Measures of Effectiveness

    Science.gov (United States)

    2017-12-01

    NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA MBA PROFESSIONAL REPORT OPERATIONAL CONTRACT SUPPORT: ECONOMIC IMPACT EVALUATION AND MEASURES...DATES COVERED MBA professional report 4. TITLE AND SUBTITLE OPERATIONAL CONTRACT SUPPORT: ECONOMIC IMPACT EVALUATION AND MEASURES OF EFFECTIVENESS 5...evaluation, expeditionary economics , operational contract support, measure of effectiveness 15. NUMBER OF PAGES 89 16. PRICE CODE 17. SECURITY

  16. System-wide significance of predation on juvenile salmonids in Columbia and Snake River reservoirs and evaluation of predation control measures. Annual report 1993

    International Nuclear Information System (INIS)

    Gadomski, D.M.; Poe, T.P.

    1994-01-01

    This project had three major goals. The first was to assist the Oregon Department of Fish and Wildlife with predation indexing as part of an effort to estimate the relative magnitude of juvenile salmonid losses to northern squawfish Ptychocheilus oregonensis in reservoirs throughout the Columbia River Basin. The second goal was to evaluate the northern squawfish control program and test critical assumptions about mid-reservoir predation processes. The final goal was to determine mechanisms underlying northern squawfish recruitment and factors affecting year-class strength

  17. Nuclear material measurement system in Brazil

    International Nuclear Information System (INIS)

    Almeida, S.G. de.

    1988-01-01

    The description of the activities developed at the Safeguards Laboratory of Brazilian Nuclear Energy Commission is done. The methods and techniques used for measuring and evaluating nuclear materials and facilities are presented. (E.G.) [pt

  18. A new telemetry-based system for assessing cardiovascular function in group-housed large animals. Taking the 3Rs to a new level with the evaluation of remote measurement via cloud data transmission.

    Science.gov (United States)

    Markert, Michael; Trautmann, Thomas; Krause, Florian; Cioaga, Marius; Mouriot, Sebastien; Wetzel, Miriam; Guth, Brian D

    2018-03-26

    A newly developed total implant telemetry system for cardiovascular (CV), electrophysiological and body temperature measurement was evaluated. A cloud-based transmission of the physiological signals allowed an assessment of the quality of the physiological signals despite the physical separation between the instrumented animals and the evaluating home laboratory. The new system is intended to be used for safety pharmacological evaluations of drug candidates in various species. Two female minipigs, 6 Labrador-mixed breed dogs and 4 female Cynomolgus monkeys were instrumented with a newly developed total implant system (TSE SYSTEMS). The implants feature a microprocessor, internal memory (1 GB), 2 solid state pressure-tipped catheters, amplifiers and a radio transmitter. Sampling rates for each measurement can be selected within a range between 0.1 and 1 kHz. Biological signals are selected in a programmable fashion on a session-by-session basis according to a user-defined protocol. The pressure sensors are at the tip of an electrical lead having a length customized to each species. Core temperature measurement and activity monitoring (3D accelerometer) are included in the system. Digital transmission range using a single antenna is 5 m with up to 16 animals held together and monitored simultaneously. The range can be expanded with more antennas in an array coupled to a single receiver. The antenna/receiver station consists of a single USB powered mobile unit connected to a PC or laptop. The battery life provides 110 days of continuous recording. The dogs and minipigs were instrumented and monitored in Germany. A novel cloud-based data transmission system was developed to monitor the physiological signals in real-time from the Cynomolgus monkeys, still kept in Mauritius, from the data evaluation laboratory in Germany. After recovery from the surgical implantation, aortic pressure (AP), left ventricular pressure (LVP), ECG and body temperature were recorded

  19. Measurement system for diffraction efficiency of convex gratings

    Science.gov (United States)

    Liu, Peng; Chen, Xin-hua; Zhou, Jian-kang; Zhao, Zhi-cheng; Liu, Quan; Luo, Chao; Wang, Xiao-feng; Tang, Min-xue; Shen, Wei-min

    2017-08-01

    A measurement system for diffraction efficiency of convex gratings is designed. The measurement system mainly includes four components as a light source, a front system, a dispersing system that contains a convex grating, and a detector. Based on the definition and measuring principle of diffraction efficiency, the optical scheme of the measurement system is analyzed and the design result is given. Then, in order to validate the feasibility of the designed system, the measurement system is set up and the diffraction efficiency of a convex grating with the aperture of 35 mm, the curvature-radius of 72mm, the blazed angle of 6.4°, the grating period of 2.5μm and the working waveband of 400nm-900nm is tested. Based on GUM (Guide to the Expression of Uncertainty in Measurement), the uncertainties in the measuring results are evaluated. The measured diffraction efficiency data are compared to the theoretical ones, which are calculated based on the grating groove parameters got by an atomic force microscope and Rigorous Couple Wave Analysis, and the reliability of the measurement system is illustrated. Finally, the measurement performance of the system is analyzed and tested. The results show that, the testing accuracy, the testing stability and the testing repeatability are 2.5%, 0.085% and 3.5% , respectively.

  20. Automatic system for ionization chamber current measurements

    International Nuclear Information System (INIS)

    Brancaccio, Franco; Dias, Mauro S.; Koskinas, Marina F.

    2004-01-01

    The present work describes an automatic system developed for current integration measurements at the Laboratorio de Metrologia Nuclear of Instituto de Pesquisas Energeticas e Nucleares. This system includes software (graphic user interface and control) and a module connected to a microcomputer, by means of a commercial data acquisition card. Measurements were performed in order to check the performance and for validating the proposed design

  1. Superconducting property measuring system by magnetization method

    International Nuclear Information System (INIS)

    Ikisawa, K.; Mori, T.; Takasu, N.

    1988-01-01

    Superconducting property measuring system (CMS-370B) for high temperature oxide superconductor has been developed. This system adopts magnetization measurement. The superconducting properties are able to be measured automatically and continuously changing the temperature and external magnetic field. The critical current density as a function of temperature and magnetic field of high temperature superconductor YBa 2 Cu 3 O 7-y (YBCO) has been measured. This paper reports how it was confirmed that this system having the high performance and the accuracy gave the significant contribution to the superconducting material development

  2. Visual Peoplemeter: A Vision-based Television Audience Measurement System

    Directory of Open Access Journals (Sweden)

    SKELIN, A. K.

    2014-11-01

    Full Text Available Visual peoplemeter is a vision-based measurement system that objectively evaluates the attentive behavior for TV audience rating, thus offering solution to some of drawbacks of current manual logging peoplemeters. In this paper, some limitations of current audience measurement system are reviewed and a novel vision-based system aiming at passive metering of viewers is prototyped. The system uses camera mounted on a television as a sensing modality and applies advanced computer vision algorithms to detect and track a person, and to recognize attentional states. Feasibility of the system is evaluated on a secondary dataset. The results show that the proposed system can analyze viewer's attentive behavior, therefore enabling passive estimates of relevant audience measurement categories.

  3. Performance measurement for information systems: Industry perspectives

    Science.gov (United States)

    Bishop, Peter C.; Yoes, Cissy; Hamilton, Kay

    1992-01-01

    Performance measurement has become a focal topic for information systems (IS) organizations. Historically, IS performance measures have dealt with the efficiency of the data processing function. Today, the function of most IS organizations goes beyond simple data processing. To understand how IS organizations have developed meaningful performance measures that reflect their objectives and activities, industry perspectives on IS performance measurement was studied. The objectives of the study were to understand the state of the practice in IS performance techniques for IS performance measurement; to gather approaches and measures of actual performance measures used in industry; and to report patterns, trends, and lessons learned about performance measurement to NASA/JSC. Examples of how some of the most forward looking companies are shaping their IS processes through measurement is provided. Thoughts on the presence of a life-cycle to performance measures development and a suggested taxonomy for performance measurements are included in the appendices.

  4. Dynamic Properties of Impulse Measuring Systems

    DEFF Research Database (Denmark)

    Pedersen, A.; Lausen, P.

    1971-01-01

    After some basic considerations the dynamic properties of the measuring system are subjected to a general examination based on a number of responses, characteristic of the system. It is demonstrated that an impulse circuit has an internal impedance different from zero, for which reason...... the interaction between the generator and the measuring circuit is of paramount importance to the voltage across the test object. Based on the measured values the determination of the applied voltage is considered....

  5. Evaluation of Real-time Measurement Liver Tumor's Movement and SynchronyTM System's Accuracy of Radiosurgery using a Robot CyberKnife

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gha Jung; Shim, Su Jung; Kim, Jeong Ho; Min, Chul Kee; Chung, Weon Kuu [Konyang University College of Medicine, Daejeon (Korea, Republic of)

    2008-12-15

    This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system (SynchronyTM). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and 13.9{+-}5.5 mm, respectively from the superior to the inferior direction, 3.9 mm and 1.9{+-}0.9 mm, respectively from left to right, and 8.3 mm and 4.9{+-}1.9 mm, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be 3.3o and 2.6{+-}1.3o, respectively for X (Left-Right) axis rotation, 4.8o and 2.3{+-}1.0o, respectively for Y (Cranio-Caudal) axis rotation, 3.9o and 2.8{+-}1.1o, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was 1

  6. Evaluation of Arctic broadband surface radiation measurements

    Science.gov (United States)

    Matsui, N.; Long, C. N.; Augustine, J.; Halliwell, D.; Uttal, T.; Longenecker, D.; Niebergall, O.; Wendell, J.; Albee, R.

    2012-02-01

    The Arctic is a challenging environment for making in-situ surface radiation measurements. A standard suite of radiation sensors is typically designed to measure incoming and outgoing shortwave (SW) and thermal infrared, or longwave (LW), radiation. Enhancements may include various sensors for measuring irradiance in narrower bandwidths. Many solar radiation/thermal infrared flux sensors utilize protective glass domes and some are mounted on complex mechanical platforms (solar trackers) that keep sensors and shading devices trained on the sun along its diurnal path. High quality measurements require striking a balance between locating stations in a pristine undisturbed setting free of artificial blockage (such as from buildings and towers) and providing accessibility to allow operators to clean and maintain the instruments. Three significant sources of erroneous data in the Arctic include solar tracker malfunctions, rime/frost/snow deposition on the protective glass domes of the radiometers and operational problems due to limited operator access in extreme weather conditions. In this study, comparisons are made between the global and component sum (direct [vertical component] + diffuse) SW measurements. The difference between these two quantities (that theoretically should be zero) is used to illustrate the magnitude and seasonality of arctic radiation flux measurement problems. The problem of rime/frost/snow deposition is investigated in more detail for one case study utilizing both SW and LW measurements. Solutions to these operational problems that utilize measurement redundancy, more sophisticated heating and ventilation strategies and a more systematic program of operational support and subsequent data quality protocols are proposed.

  7. Ultrasonic nondestructive evaluation systems industrial application issues

    CERN Document Server

    Callegari, Sergio; Montisci, Augusto; Ricci, Marco; Versaci, Mario

    2015-01-01

    This book covers the practical implementation of ultrasonic NDT techniques in an industrial environment, discussing several issues that may emerge and proposing strategies for addressing them successfully.  It aims to bridge advanced academic research results and their application to industrial procedures. The topics covered in the text range from the basic operation of an ultrasonic NDT system to the simulation of the measurement operations; from the choice and generation of the signals energizing the system to the different ways of exploiting the probes and their output signals; and from quality assessment evaluation to the use of soft computing techniques for classification. Throughout the text, an effort is made to embrace a system view where the physical and technological aspects of sensing are addressed together with higher abstraction levels, such as signal and information processing. Consequently, the book aims at guiding the reader through the various tasks requested for developing a complete ultras...

  8. The Simplest Evaluation Measures for XML Information Retrieval that Could Possibly Work

    NARCIS (Netherlands)

    Hiemstra, Djoerd; Mihajlovic, V.

    2005-01-01

    This paper reviews several evaluation measures developed for evaluating XML information retrieval (IR) systems. We argue that these measures, some of which are currently in use by the INitiative for the Evaluation of XML Retrieval (INEX), are complicated, hard to understand, and hard to explain to

  9. Electronic instrumentation system for pulsed neutron measurements

    International Nuclear Information System (INIS)

    Burda, J.; Igielski, A.; Kowalik, W.

    1982-01-01

    An essential point of pulsed neutron measurement of thermal neutron parameters for different materials is the registration of the thermal neutron die-away curve after a fast neutron bursts have been injected into the system. An electronic instrumentation system which is successfully applied for pulsed neutron measurements is presented. An important part of the system is the control unit which has been designed and built in the Laboratory of Neutron Parameters of Materials. (author)

  10. Front-End Electronics for Verification Measurements: Performance Evaluation and Viability of Advanced Tamper Indicating Measures

    International Nuclear Information System (INIS)

    Smith, E.; Conrad, R.; Morris, S.; Ramuhalli, P.; Sheen, D.; Schanfein, M.; Ianakiev, K.; Browne, M.; Svoboda, J.

    2015-01-01

    The International Atomic Energy Agency (IAEA) continues to expand its use of unattended, remotely monitored measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. A collaboration between Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL), and Los Alamos National Laboratory (LANL) is working to advance the IAEA's capabilities in these areas. The first objective of the project is to perform a comprehensive evaluation of a prototype front-end electronics package, as specified by the IAEA and procured from a commercial vendor. This evaluation begins with an assessment against the IAEA's original technical specifications and expands to consider the strengths and limitations over a broad range of important parameters that include: sensor types, cable types, and the spectrum of industrial electromagnetic noise that can degrade signals from remotely located detectors. A second objective of the collaboration is to explore advanced tamper-indicating (TI) measures that could help to address some of the long-standing data authentication challenges with IAEA's unattended systems. The collaboration has defined high-priority tampering scenarios to consider (e.g., replacement of sensor, intrusion into cable), and drafted preliminary requirements for advanced TI measures. The collaborators are performing independent TI investigations of different candidate approaches: active time-domain reflectometry (PNNL), passive noise analysis (INL), and pulse-by-pulse analysis and correction (LANL). The initial investigations focus on scenarios where new TI measures are retrofitted into existing IAEA UMS deployments; subsequent work will consider the integration of advanced TI methods into new IAEA UMS deployments where the detector is separated from the front-end electronics. In this paper, project progress

  11. Perturbation measurements in reactor LR-0 and their evaluation

    International Nuclear Information System (INIS)

    Rypar, W.; Faehrmann, K.H.

    1988-07-01

    To investigate space-dependent kinetic effects in reactors of the WWER-1000 type, two central and one eccentric perturbation measurements were performed in the zero power reactor LR-0 of the UJV Rez (CSSR) by trapeze-form movements of an absorber cluster. The measurements were based ona computer aided CAMAC system for the simultaneous data acquisition of 20 spatially distributed neutron detectors and for cluster movement control. The measurements were followed by a detailed evaluation in the ZfK Rossendorf (GDR) with respect to the calculation results of flux response obtained by nodal code HEXDYN3D, the aim of which was to demostrate the limits of the point reactor model and to account for space-dependent effects by approximative methods. A sensitive check of the calculation methods was made possible especially by the eccentric perturbation where the space dependent effects,due to a larger distance of cluster movement, were most significant. (author). 17 figs., 9 refs

  12. Evaluation of Arctic broadband surface radiation measurements

    Directory of Open Access Journals (Sweden)

    N. Matsui

    2012-02-01

    Full Text Available The Arctic is a challenging environment for making in-situ surface radiation measurements. A standard suite of radiation sensors is typically designed to measure incoming and outgoing shortwave (SW and thermal infrared, or longwave (LW, radiation. Enhancements may include various sensors for measuring irradiance in narrower bandwidths. Many solar radiation/thermal infrared flux sensors utilize protective glass domes and some are mounted on complex mechanical platforms (solar trackers that keep sensors and shading devices trained on the sun along its diurnal path. High quality measurements require striking a balance between locating stations in a pristine undisturbed setting free of artificial blockage (such as from buildings and towers and providing accessibility to allow operators to clean and maintain the instruments. Three significant sources of erroneous data in the Arctic include solar tracker malfunctions, rime/frost/snow deposition on the protective glass domes of the radiometers and operational problems due to limited operator access in extreme weather conditions. In this study, comparisons are made between the global and component sum (direct [vertical component] + diffuse SW measurements. The difference between these two quantities (that theoretically should be zero is used to illustrate the magnitude and seasonality of arctic radiation flux measurement problems. The problem of rime/frost/snow deposition is investigated in more detail for one case study utilizing both SW and LW measurements. Solutions to these operational problems that utilize measurement redundancy, more sophisticated heating and ventilation strategies and a more systematic program of operational support and subsequent data quality protocols are proposed.

  13. Measurement system analysis for one-sided tolerance

    Directory of Open Access Journals (Sweden)

    Szemik Kamil

    2017-01-01

    Full Text Available Measurement system analysis is carried out in order to determine if a capability to perform measurements in terms of product and process control is sufficient, indicating that the type I and the type II appraisal errors probability are acceptable. Statistical analyses for measurement system evaluation presented in the literature and the industrial manuals are not applicable for all complex and unusual applications. Therefore, the purpose of this study was to develop a robust statistical analysis method for measurement system variability analysis, in terms of product control scenario applied to one-sided tolerance. In the hereby presented study, the authors presented the theoretical principles of statistical techniques for measurement variations evaluation. Subsequently, the formula of gauge repeatability and reproducibility in terms of lower specification limit was proposed. The research hypothesis was tested using the statistical analysis.

  14. System Entropy Measurement of Stochastic Partial Differential Systems

    Directory of Open Access Journals (Sweden)

    Bor-Sen Chen

    2016-03-01

    Full Text Available System entropy describes the dispersal of a system’s energy and is an indication of the disorder of a physical system. Several system entropy measurement methods have been developed for dynamic systems. However, most real physical systems are always modeled using stochastic partial differential dynamic equations in the spatio-temporal domain. No efficient method currently exists that can calculate the system entropy of stochastic partial differential systems (SPDSs in consideration of the effects of intrinsic random fluctuation and compartment diffusion. In this study, a novel indirect measurement method is proposed for calculating of system entropy of SPDSs using a Hamilton–Jacobi integral inequality (HJII-constrained optimization method. In other words, we solve a nonlinear HJII-constrained optimization problem for measuring the system entropy of nonlinear stochastic partial differential systems (NSPDSs. To simplify the system entropy measurement of NSPDSs, the global linearization technique and finite difference scheme were employed to approximate the nonlinear stochastic spatial state space system. This allows the nonlinear HJII-constrained optimization problem for the system entropy measurement to be transformed to an equivalent linear matrix inequalities (LMIs-constrained optimization problem, which can be easily solved using the MATLAB LMI-toolbox (MATLAB R2014a, version 8.3. Finally, several examples are presented to illustrate the system entropy measurement of SPDSs.

  15. Evaluation of Cow Milk Electrical Conductivity Measurements

    Directory of Open Access Journals (Sweden)

    Constantin Gavan

    2017-11-01

    Full Text Available The efficiency of subclinical mastitis diagnosis using an electrical conductivity (EC meter was evaluated in the dairy farm of Agricultural Research and Development Station ( ARDS Simnic Craiova. The results were compared with those obtained by using the California Mastitis Test (CMT and the Somatic Cell Count (SCC.The milk quarter samples ( 1176 from Holstein Friesian cows were analyzed between September and December 2015. The EC evaluation with  the EC meter  ,showed a high proportion of results differing from SCC and CMT results. The CMT still shows to be the most accessible and efficient test in comparison to the EC meter tested.

  16. Entropy Measurement for Biometric Verification Systems.

    Science.gov (United States)

    Lim, Meng-Hui; Yuen, Pong C

    2016-05-01

    Biometric verification systems are designed to accept multiple similar biometric measurements per user due to inherent intrauser variations in the biometric data. This is important to preserve reasonable acceptance rate of genuine queries and the overall feasibility of the recognition system. However, such acceptance of multiple similar measurements decreases the imposter's difficulty of obtaining a system-acceptable measurement, thus resulting in a degraded security level. This deteriorated security needs to be measurable to provide truthful security assurance to the users. Entropy is a standard measure of security. However, the entropy formula is applicable only when there is a single acceptable possibility. In this paper, we develop an entropy-measuring model for biometric systems that accepts multiple similar measurements per user. Based on the idea of guessing entropy, the proposed model quantifies biometric system security in terms of adversarial guessing effort for two practical attacks. Excellent agreement between analytic and experimental simulation-based measurement results on a synthetic and a benchmark face dataset justify the correctness of our model and thus the feasibility of the proposed entropy-measuring approach.

  17. A minimally invasive system for glucose area under the curve measurement using interstitial fluid extraction technology: evaluation of the accuracy and usefulness with oral glucose tolerance tests in subjects with and without diabetes.

    Science.gov (United States)

    Sakaguchi, Kazuhiko; Hirota, Yushi; Hashimoto, Naoko; Ogawa, Wataru; Sato, Toshiyuki; Okada, Seiki; Hagino, Kei; Asakura, Yoshihiro; Kikkawa, Yasuo; Kojima, Junko; Maekawa, Yasunori; Nakajima, Hiromu

    2012-06-01

    Recent studies have highlighted the importance of managing postprandial hyperglycemia, but adequate monitoring of postprandial glucose remains difficult because of wide variations in levels. We have therefore developed a minimally invasive system to monitor postprandial glucose area under the curve (AUC). This system involves no blood sampling and uses interstitial fluid glucose (IG) AUC (IG-AUC) as a surrogate marker of postprandial glucose. This study aimed to evaluate the usefulness of this system by comparing data with the findings of oral glucose tolerance tests (OGTTs) in subjects with and without diabetes. The glucose AUC monitoring system was validated by OGTTs in 37 subjects with and 10 subjects without diabetes. A plastic microneedle array was stamped on the forearm to extract IG. A hydrogel patch was then placed on the pretreated area to accumulate IG. Glucose and sodium ion concentrations in the hydrogel were measured to calculate IG-AUC at 2-h postload glucose. Plasma glucose (PG) levels were measured every 30 min to calculate reference PG-AUC. IG-AUC correlated strongly with reference PG-AUC (r=0.93) over a wide range. The level of correlation between IG-AUC and maximum PG level was also high (r=0.86). The painless nature of the technique was confirmed by the response of patients to questionnaires. The glucose AUC monitoring system using IG provided good estimates of reference PG-AUC and maximum PG level during OGTTs in subjects with and without diabetes. This system provides easy-to-use monitoring of glucose AUC, which is a good indicator of postprandial glucose.

  18. Temperature measurement systems in wearable electronics

    Science.gov (United States)

    Walczak, S.; Gołebiowski, J.

    2014-08-01

    The aim of this paper is to present the concept of temperature measurement system, adapted to wearable electronics applications. Temperature is one of the most commonly monitored factor in smart textiles, especially in sportswear, medical and rescue products. Depending on the application, measured temperature could be used as an initial value of alert, heating, lifesaving or analysis system. The concept of the temperature measurement multi-point system, which consists of flexible screen-printed resistive sensors, placed on the T-shirt connected with the central unit and the power supply is elaborated in the paper.

  19. Seat pressure measurement technologies: considerations for their evaluation.

    Science.gov (United States)

    Gyi, D E; Porter, J M; Robertson, N K

    1998-04-01

    Interface pressure measurement has generated interest in the automotive industry as a technique which could be used in the prediction of driver discomfort for various car seat designs, and provide designers and manufacturers with rapid information early on in the design process. It is therefore essential that the data obtained are of the highest quality, relevant and have some quantitative meaning. Exploratory experimental work carried out with the commercially available Talley Pressure Monitor is outlined. This led to a better understanding of the strengths and weaknesses of this system and the re-design of the sensor matrix. Such evaluation, in the context of the actual experimental environment, is considered essential.

  20. Multicenter Evaluation of Cystatin C Measurement after Assay Standardization.

    Science.gov (United States)

    Bargnoux, Anne-Sophie; Piéroni, Laurence; Cristol, Jean-Paul; Kuster, Nils; Delanaye, Pierre; Carlier, Marie-Christine; Fellahi, Soraya; Boutten, Anne; Lombard, Christine; González-Antuña, Ana; Delatour, Vincent; Cavalier, Etienne

    2017-04-01

    Since 2010, a certified reference material ERM-DA471/IFCC has been available for cystatin C (CysC). This study aimed to assess the sources of uncertainty in results for clinical samples measured using standardized assays. This evaluation was performed in 2015 and involved 7 clinical laboratories located in France and Belgium. CysC was measured in a panel of 4 serum pools using 8 automated assays and a candidate isotope dilution mass spectrometry reference measurement procedure. Sources of uncertainty (imprecision and bias) were evaluated to calculate the relative expanded combined uncertainty for each CysC assay. Uncertainty was judged against the performance specifications derived from the biological variation model. Only Siemens reagents on the Siemens systems and, to a lesser extent, DiaSys reagents on the Cobas system, provided results that met the minimum performance criterion calculated according to the intraindividual and interindividual biological variations. Although the imprecision was acceptable for almost all assays, an increase in the bias with concentration was observed for Gentian reagents, and unacceptably high biases were observed for Abbott and Roche reagents on their own systems. This comprehensive picture of the market situation since the release of ERM-DA471/IFCC shows that bias remains the major component of the combined uncertainty because of possible problems associated with the implementation of traceability. Although some manufacturers have clearly improved their calibration protocols relative to ERM-DA471, most of them failed to meet the criteria for acceptable CysC measurements. © 2016 American Association for Clinical Chemistry.

  1. The efficacy of stuttering measurement training: evaluating two training programs.

    Science.gov (United States)

    Bainbridge, Lauren A; Stavros, Candace; Ebrahimian, Mineh; Wang, Yuedong; Ingham, Roger J

    2015-04-01

    Two stuttering measurement training programs currently used for training clinicians were evaluated for their efficacy in improving the accuracy of total stuttering event counting. Four groups, each with 12 randomly allocated participants, completed a pretest-posttest design training study. They were evaluated by their counts of stuttering events on eight 3-min audiovisual speech samples from adults and children who stutter. Stuttering judgment training involved use of either the Stuttering Measurement System (SMS), Stuttering Measurement Assessment and Training (SMAAT) programs, or no training. To test for the reliability of any training effect, SMS training was repeated with the 4th group. Both SMS-trained groups produced approximately 34% improvement, significantly better than no training or the SMAAT program. The SMAAT program produced a mixed result. The SMS program was shown to produce a "medium" effect size improvement in the accuracy of stuttering event counts, and this improvement was almost perfectly replicated in a 2nd group. Half of the SMAAT judges produced a 36% improvement in accuracy, but the other half showed no improvement. Additional studies are needed to demonstrate the durability of the reported improvements, but these positive effects justify the importance of stuttering measurement training.

  2. Measurement and analysis of operating system fault tolerance

    Science.gov (United States)

    Lee, I.; Tang, D.; Iyer, R. K.

    1992-01-01

    This paper demonstrates a methodology to model and evaluate the fault tolerance characteristics of operational software. The methodology is illustrated through case studies on three different operating systems: the Tandem GUARDIAN fault-tolerant system, the VAX/VMS distributed system, and the IBM/MVS system. Measurements are made on these systems for substantial periods to collect software error and recovery data. In addition to investigating basic dependability characteristics such as major software problems and error distributions, we develop two levels of models to describe error and recovery processes inside an operating system and on multiple instances of an operating system running in a distributed environment. Based on the models, reward analysis is conducted to evaluate the loss of service due to software errors and the effect of the fault-tolerance techniques implemented in the systems. Software error correlation in multicomputer systems is also investigated.

  3. A transuranic aerosol measurement system: Preliminary results

    International Nuclear Information System (INIS)

    Prevo, C.T.; Kaifer, R.C.; Rueppel, D.W.; Delvasto, R.M.; Biermann, A.H.; Phelps, P.L.

    1986-10-01

    We have completed the design, fabrication, and assembly of a computer-based prototype system for the measurement of transuranic aerosols in the workplace and environment. This system (called WOTAMS for Workplace Transuranic Aerosol Measurement System) incorporates two detectors: (1) an in-line solid-state alpha detector that sends out an alarm the moment a transuranic release occurs, and (2) an in-vacuum detector that increases off-line-analysis sensitivity. The in-line sensitivity of the system is better than 5.0 MPC-h, and the in-vacuum sensitivity exceeds 0.5 MPC-h. 5 refs., 8 figs., 1 tab

  4. Evaluation of measures of urinary albumin excretion

    NARCIS (Netherlands)

    Gansevoort, Ronald T.; Brinkman, Jacoline; Bakker, Stephan J. L.; De Jong, Paul E.; de Zeeuw, Dick

    2006-01-01

    Albuminuria has recently drawn much attention as a valuable risk marker for cardiovascular and renal disease progression. Albuminuria can be measured and expressed in several ways: 1) in a spot morning urine sample as urinary albumin concentration (mg/liter) or albumin:creatinine ratio (mg/mmol) and

  5. Measurement and evaluation of internal dose

    International Nuclear Information System (INIS)

    Lee, Tae Young; Chang, S. Y.; Lee, J. I.; Song, M. Y.

    2006-01-01

    This report describes the contents and results for implementation of internal radiation monitoring programme, measurement of uranium present in lung by lung counter and assessment of committed effective dose for radiation workers of the KNFC. The aim of radiation protection was achieved by implementing this activity

  6. A computerized system for handling renal size measurements from urograms

    International Nuclear Information System (INIS)

    Claesson, I.; Jacobsson, B.F.; Riha, M.

    1987-01-01

    The size of a kidney, as measured on an urogram, is a sensitive indicator of renal damage in a child with urinary tract infection, and renal surface area correlates well with glomerular filtration rate. Sequential measurements can be invaluable in evaluating the efficacy of a regimen of treatment. A system utilizing a personal microcomputer has been developed to facilitate the measuring procedure and the handling and analysis of data. (orig.)

  7. Analysis of measurement system as the mechatronics system

    Energy Technology Data Exchange (ETDEWEB)

    Giniotis, V [Institute of Geodesy, Vilnius Gediminas Technical University, Vilnius, Lithuania, Sauletekio al. 11, 10223 Vilnius-40, Lithuania, Fax: 370 5 2744 705 (Lithuania); Grattan, K T V [School of Engineering and Mathematical Sciences Electrical, Electronic and Information Eng, City University, Northampton Square, London EC1V 0HB (United Kingdom); Rybokas, M [Department of Information Technologies, Vilnius Gediminas Technical University, Sauletekio al. 11, 10223 Vilnius-40, Lithuania, Fax: 370 5 2744 705 (Lithuania); Brucas, D, E-mail: gi@ap.vtu.l, E-mail: k.t.v.grattan@city.ac.u, E-mail: MRybokas@gama.l, E-mail: domka@ktv.l, E-mail: vg@ai.vgtu.l [Department of Geodesy and Cadastre, Vilnius Gediminas Technical University, Vilnius, Lithuania Sauletekio al. 11, 10223 Vilnius-40, Lithuania, Fax: 370 5 2744 705 (Lithuania)

    2010-07-01

    The paper deals with the mechatronic arrangement for angle measuring system application. The objects to be measured are the circular raster scales, rotary encoders and coded scales. The task of the measuring system is to determine the bias of angle measuring standard as the circular scale and to use the results for the error correction and accuracy improvement of metal cutting machines, coordinate measuring machines, robots, etc. The technical solutions are given with the application of active materials for smart piezoactuators implemented into the several positions of angular measuring equipment. Mechatronic measuring system is analysed as complex integrated system and some of its elements can be used as separate units. All these functional elements are described and commented in the paper with the diagrams and graphs of errors and examples of microdisplacement devices using the mechatronic elements.

  8. Analysis of measurement system as the mechatronics system

    International Nuclear Information System (INIS)

    Giniotis, V; Grattan, K T V; Rybokas, M; Brucas, D

    2010-01-01

    The paper deals with the mechatronic arrangement for angle measuring system application. The objects to be measured are the circular raster scales, rotary encoders and coded scales. The task of the measuring system is to determine the bias of angle measuring standard as the circular scale and to use the results for the error correction and accuracy improvement of metal cutting machines, coordinate measuring machines, robots, etc. The technical solutions are given with the application of active materials for smart piezoactuators implemented into the several positions of angular measuring equipment. Mechatronic measuring system is analysed as complex integrated system and some of its elements can be used as separate units. All these functional elements are described and commented in the paper with the diagrams and graphs of errors and examples of microdisplacement devices using the mechatronic elements.

  9. Fission yield data evaluation system FYDES

    International Nuclear Information System (INIS)

    Liu Tingjin

    1998-01-01

    Taking account of some features of fission yield data, to do the fission yield data evaluation conveniently, a fission yield data evaluation system FYDES has been developed for last two years. Outline of the system, data retrieval and data table standardization, data correction codes, data averaging code, simultaneous evaluation code and data fit programs were introduced

  10. Integral Criteria for Measuring the Quality of Teacher Evaluation

    Directory of Open Access Journals (Sweden)

    Olga Navickienė

    2012-07-01

    Full Text Available Purpose—To construct the knowledge evaluation quality integral criteria, which allows to ascertain whether the different teachers properly assess the students’ knowledge. The criteria has been tested setting up the educational experiment and examining the six mathematics lecturers’ assessments.Design/methodology/approach—This research involved the Mykolas Romeris University students of Public Administration degree second year and Management of Organizations degree first year. The test questions for students were designed using the mathematical knowledge assessment information system, which allows for closed-ended mathematical test, to obtain statistical data about test takers, to perform quality analysis of the test; in the middle and the end of the semester.Findings—The construction technique for the evaluation quality criteria of the students’ working results assessment, which were performed by six different lecturers, during practical trainings, seminars, laboratory and other sessions is proposed in this article.Research limitations/implications—The constructed evaluation criteria is universal: it does not depend on the particular subject; it can be applied to several groups, courses or lecturers. It depends on three calculated indicators I, S, K, which show in two ways obtained estimates of the measured information compatibility of degrees, marks matching and correlation terms.Practical implications—The integral criteria has been tested examining the six mathematics lecturers’ assessments.Originality/Value—Constructing the criteria have been used the educational measurement models of authors of this article and other researchers, however its’ connection to general (integral criteria, best of authors’ knowledge, is original and have not be researched before.Keywords: knowledge evaluation, quality of teacher evaluation, evaluation of teachers, mathematical modeling.Research type: research paper.

  11. Measurement system as a subsystem of the quality management system

    Directory of Open Access Journals (Sweden)

    Ľubica Floreková

    2006-12-01

    Full Text Available Each measurement system and a control principle must be based on certain facts about the system behaviour (what, operation (how and structure (why. Each system is distributed into subsystems that provide an input for the next subsystem. For each system, start is important the begin, that means system characteristics, collecting of data, its hierarchy and the processes distribution.A measurement system (based on the chapter 8 of the standard ISO 9001:2000 Quality management system, requirements defines the measurement, analysis and improvement for each organization in order to present the products conformity, the quality management system conformity guarantee and for the continuously permanent improvement of effectivity, efficiency and economy of quality management system.

  12. A system for pulse Hall effect measurements

    International Nuclear Information System (INIS)

    Orzechowski, T.; Kupczak, R.

    1975-01-01

    Measuring system for fast Hall-voltage changes in an n-type germanium sample irradiated at liquid nitrogen temperature with a high-energy electron-beam from the Van de Graaff accelerator is described. (author)

  13. Telemetric measurement system of beehive environment conditions

    Science.gov (United States)

    Walendziuk, Wojciech; Sawicki, Aleksander

    2014-11-01

    This work presents a measurement system of beehive environmental conditions. The purpose of the device is to perform measurements of parameters such as ambient temperature, atmospheric pressure, internal temperature, humidity and sound level. The measured values were transferred to the MySQL database, which is located on an external server, with the use of GPRS protocol. A website presents the measurement data in the form of tables and graphs. The study also shows exemplary results of environmental conditions measurements recorded in the beehive by hour cycle.

  14. An evaluation of classification systems for stillbirth

    Directory of Open Access Journals (Sweden)

    Pattinson Robert

    2009-06-01

    Full Text Available Abstract Background Audit and classification of stillbirths is an essential part of clinical practice and a crucial step towards stillbirth prevention. Due to the limitations of the ICD system and lack of an international approach to an acceptable solution, numerous disparate classification systems have emerged. We assessed the performance of six contemporary systems to inform the development of an internationally accepted approach. Methods We evaluated the following systems: Amended Aberdeen, Extended Wigglesworth; PSANZ-PDC, ReCoDe, Tulip and CODAC. Nine teams from 7 countries applied the classification systems to cohorts of stillbirths from their regions using 857 stillbirth cases. The main outcome measures were: the ability to retain the important information about the death using the InfoKeep rating; the ease of use according to the Ease rating (both measures used a five-point scale with a score Results InfoKeep scores were significantly different across the classifications (p ≤ 0.01 due to low scores for Wigglesworth and Aberdeen. CODAC received the highest mean (SD score of 3.40 (0.73 followed by PSANZ-PDC, ReCoDe and Tulip [2.77 (1.00, 2.36 (1.21, 1.92 (1.24 respectively]. Wigglesworth and Aberdeen resulted in a high proportion of unexplained stillbirths and CODAC and Tulip the lowest. While Ease scores were different (p ≤ 0.01, all systems received satisfactory scores; CODAC received the highest score. Aberdeen and Wigglesworth showed poor agreement with kappas of 0.35 and 0.25 respectively. Tulip performed best with a kappa of 0.74. The remainder had good to fair agreement. Conclusion The Extended Wigglesworth and Amended Aberdeen systems cannot be recommended for classification of stillbirths. Overall, CODAC performed best with PSANZ-PDC and ReCoDe performing well. Tulip was shown to have the best agreement and a low proportion of unexplained stillbirths. The virtues of these systems need to be considered in the development of an

  15. An evaluation of classification systems for stillbirth.

    Science.gov (United States)

    Flenady, Vicki; Frøen, J Frederik; Pinar, Halit; Torabi, Rozbeh; Saastad, Eli; Guyon, Grace; Russell, Laurie; Charles, Adrian; Harrison, Catherine; Chauke, Lawrence; Pattinson, Robert; Koshy, Rachel; Bahrin, Safiah; Gardener, Glenn; Day, Katie; Petersson, Karin; Gordon, Adrienne; Gilshenan, Kristen

    2009-06-19

    Audit and classification of stillbirths is an essential part of clinical practice and a crucial step towards stillbirth prevention. Due to the limitations of the ICD system and lack of an international approach to an acceptable solution, numerous disparate classification systems have emerged. We assessed the performance of six contemporary systems to inform the development of an internationally accepted approach. We evaluated the following systems: Amended Aberdeen, Extended Wigglesworth; PSANZ-PDC, ReCoDe, Tulip and CODAC. Nine teams from 7 countries applied the classification systems to cohorts of stillbirths from their regions using 857 stillbirth cases. The main outcome measures were: the ability to retain the important information about the death using the InfoKeep rating; the ease of use according to the Ease rating (both measures used a five-point scale with a score <2 considered unsatisfactory); inter-observer agreement and the proportion of unexplained stillbirths. A randomly selected subset of 100 stillbirths was used to assess inter-observer agreement. InfoKeep scores were significantly different across the classifications (p < or = 0.01) due to low scores for Wigglesworth and Aberdeen. CODAC received the highest mean (SD) score of 3.40 (0.73) followed by PSANZ-PDC, ReCoDe and Tulip [2.77 (1.00), 2.36 (1.21), 1.92 (1.24) respectively]. Wigglesworth and Aberdeen resulted in a high proportion of unexplained stillbirths and CODAC and Tulip the lowest. While Ease scores were different (p < or = 0.01), all systems received satisfactory scores; CODAC received the highest score. Aberdeen and Wigglesworth showed poor agreement with kappas of 0.35 and 0.25 respectively. Tulip performed best with a kappa of 0.74. The remainder had good to fair agreement. The Extended Wigglesworth and Amended Aberdeen systems cannot be recommended for classification of stillbirths. Overall, CODAC performed best with PSANZ-PDC and ReCoDe performing well. Tulip was shown to have the

  16. Organic indoor air pollutants: occurrence, measurement, evaluation

    National Research Council Canada - National Science Library

    Salthammer, Tunga; Uhde, Erik

    2009-01-01

    ... hand, organic chemical pollutants emitted from materials and appliances can adversely affect human health. People in developed countries spend more than 90% of their time indoors. In the light of this fact, the cleanliness of occupied spaces such as buildings, houses, and transportation systems becomes very important. In contemporary so...

  17. Measures of Situation Awareness: An Experimental Evaluation

    Science.gov (United States)

    1991-10-01

    occurrence from non- occurrence of the target event, referred to as sensitivity (Macmillan and Creelman , 1990). Because sensitivity declines if pilots are...Pollack and Norman, 1964; see also Craig, 1979; Macmillan and Creelman , 1990). Finally, avoidance failures were measured simply as the number of times...Wesley. Macmillan, N. A., & Creelman , C. D. (1990). Response bias: Characteristics of detection theory, threshold theory, and "non- parametric" indexes

  18. Bioimpedance measurement based evaluation of wound healing.

    Science.gov (United States)

    Kekonen, Atte; Bergelin, Mikael; Eriksson, Jan-Erik; Vaalasti, Annikki; Ylänen, Heimo; Viik, Jari

    2017-06-22

    Our group has developed a bipolar bioimpedance measurement-based method for determining the state of wound healing. The objective of this study was to assess the capability of the method. To assess the performance of the method, we arranged a follow-up study of four acute wounds. The wounds were measured using the method and photographed throughout the healing process. Initially the bioimpedance of the wounds was significantly lower than the impedance of the undamaged skin, used as a baseline. Gradually, as healing progressed, the wound impedance increased and finally reached the impedance of the undamaged skin. The clinical appearance of the wounds examined in this study corresponded well with the parameters derived from the bioimpedance data. Hard-to-heal wounds are a significant and growing socioeconomic burden, especially in the developed countries, due to aging populations and to the increasing prevalence of various lifestyle related diseases. The assessment and the monitoring of chronic wounds are mainly based on visual inspection by medical professionals. The dressings covering the wound must be removed before assessment; this may disturb the wound healing process and significantly increases the work effort of the medical staff. There is a need for an objective and quantitative method for determining the status of a wound without removing the wound dressings. This study provided evidence of the capability of the bioimpedance based method for assessing the wound status. In the future measurements with the method should be extended to concern hard-to-heal wounds.

  19. Distance and Cable Length Measurement System

    Science.gov (United States)

    Hernández, Sergio Elias; Acosta, Leopoldo; Toledo, Jonay

    2009-01-01

    A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement. PMID:22303169

  20. Automated statistical modeling of analytical measurement systems

    International Nuclear Information System (INIS)

    Jacobson, J.J.

    1992-01-01

    The statistical modeling of analytical measurement systems at the Idaho Chemical Processing Plant (ICPP) has been completely automated through computer software. The statistical modeling of analytical measurement systems is one part of a complete quality control program used by the Remote Analytical Laboratory (RAL) at the ICPP. The quality control program is an integration of automated data input, measurement system calibration, database management, and statistical process control. The quality control program and statistical modeling program meet the guidelines set forth by the American Society for Testing Materials and American National Standards Institute. A statistical model is a set of mathematical equations describing any systematic bias inherent in a measurement system and the precision of a measurement system. A statistical model is developed from data generated from the analysis of control standards. Control standards are samples which are made up at precise known levels by an independent laboratory and submitted to the RAL. The RAL analysts who process control standards do not know the values of those control standards. The object behind statistical modeling is to describe real process samples in terms of their bias and precision and, to verify that a measurement system is operating satisfactorily. The processing of control standards gives us this ability

  1. SPEED ROLLER STAND MEASUREMENT SYSTEM CHECKING TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Y. Zybtsev

    2011-01-01

    Full Text Available The study has shown that the accuracy of brakes checking by inertial stands depends upon the applied methods of measurement of braking parameters (stand slowing down, braking distance, brakes triggering time, current speed as well as the methods of metrological checking of measuring system canals.

  2. Evaluation of mobile systems: an integrative framework.

    NARCIS (Netherlands)

    Högler, T.; Versendaal, J.; Batenburg, R.

    2015-01-01

    This work presents an integrative framework for the evaluation of mobile systems. In comparison to stationary systems, mobile systems have a bundle of specific singularities that should be considered for evaluation. Further analysis of existing approaches clarifies that an integrative approach for

  3. Measurement trends for future safeguards systems

    International Nuclear Information System (INIS)

    Baloga, S.M.; Hakkila, E.A.

    1980-01-01

    Safeguards for future commercial-scale nuclear facilities may employ three materials control and accounting concepts: classical accounting, dynamic materials balancing, and independent verification of inventories and materials balances. Typical measurement needs associated with the implementation of these concepts at high-throughput facilities are discussed. Promising measurement methods for meeting these needs are described and recent experience is cited. General directions and considerations for meeting advanced safeguards systems needs through measurement technology development over the next decade are presented

  4. Analyze of the Measuring Performance for Artificially Business Intelligent Systems

    OpenAIRE

    Vatuiu, Teodora

    2007-01-01

    This paper analyzes the measuring performance of artificially business intelligent systems. Thousands of persons-years have been devoted to the research and development in the vari¬ous aspects of artificially intelligent systems. Much progress has been attained. However, there has been no means of evaluating the progress of the field. How can we assess the cur¬rent state of the science? Most of business intelligent systems are beginning to be deployed commercially. How can a commercial buyer ...

  5. Intravenous flurbiprofen axetil can stabilize the hemodynamic instability due to mesenteric traction syndrome--evaluation with continuous measurement of the systemic vascular resistance index using a FloTrac® sensor.

    Science.gov (United States)

    Takada, Motoshi; Taruishi, Chieko; Sudani, Tomoko; Suzuki, Akira; Iida, Hiroki

    2013-08-01

    Evaluation of the stabilizing effect of intravenous flurbiprofen axetil against hemodynamic instability due to mesenteric traction syndrome (MTS) by continuous measurement of systemic vascular resistance index (SVRI) using a FloTrac(®) sensor was evaluated. Prospective randomized trial. A single-center study performed in an educational hospital. Two prospective studies were carried out, each with 40 patients scheduled for elective open abdominal surgery. Twenty patients received 50 mg of flurbiprofen axetil after the recognition of MTS by the anesthesiologist (group FT). The remaining patients served as controls (groups CP and CT). SVRI data was collected every 20 seconds for 1 hour after starting the laparotomy. The average SVRI prior to skin incision was taken as the baseline. Following 3 values were devised to evaluate MTS: the S-value (sum total of changes in SVRI from baseline), the T-value (period during which SVRI remained 20% or more below baseline), and the M-value (maximum change in SVRI from baseline). In group FP, decrease in SVRI was smaller than in group CP, and statistical differences in the 3 values were found. In group FT, SVRI recovered earlier than in group CT, and statistical differences were found in S-value and T-value. However, the M-value had no statistical differences. Intravenous flurbiprofen axetil can stabilize the hemodynamic instability due to MTS. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Pervious Pavement System Evaluation- Abstract

    Science.gov (United States)

    Porous pavement is a low impact development stormwater control. The Urban Watershed Management Branch is evaluating interlocking concrete pavers as a popular implementation. The pavers themselves are impermeable, but the spaces between the pavers are backfilled with washed, gra...

  7. CITYkeys Smart city performance measurement system

    NARCIS (Netherlands)

    Huovila, A.; Airaksinen, M.; Pinto-Seppa, I.; Piira, K.; Bosch, P.R.; Penttinen, T.; Neumann, H.M.; Kontinakis, N.

    2017-01-01

    Cities are tackling their economic, social and environmental challenges through smart city solutions. To demonstrate that these solutions achieve the desired impact, an indicator-based assessment system is needed. This paper presents the process of developing CITYkeys performance measurement system

  8. Telerobotic system performance measurement - Motivation and methods

    Science.gov (United States)

    Kondraske, George V.; Khoury, George J.

    1992-01-01

    A systems performance-based strategy for modeling and conducting experiments relevant to the design and performance characterization of telerobotic systems is described. A developmental testbed consisting of a distributed telerobotics network and initial efforts to implement the strategy described is presented. Consideration is given to the general systems performance theory (GSPT) to tackle human performance problems as a basis for: measurement of overall telerobotic system (TRS) performance; task decomposition; development of a generic TRS model; and the characterization of performance of subsystems comprising the generic model. GSPT employs a resource construct to model performance and resource economic principles to govern the interface of systems to tasks. It provides a comprehensive modeling/measurement strategy applicable to complex systems including both human and artificial components. Application is presented within the framework of a distributed telerobotics network as a testbed. Insight into the design of test protocols which elicit application-independent data is described.

  9. Internal Performance Measurement Systems: Problems and Solutions

    DEFF Research Database (Denmark)

    Jakobsen, Morten; Mitchell, Falconer; Nørreklit, Hanne

    2010-01-01

    This article pursues two aims: to identify problems and dangers related to the operational use of internal performance measurement systems of the Balanced Scorecard (BSC) type and to provide some guidance on how performance measurement systems may be designed to overcome these problems....... The analysis uses and extends N rreklit's (2000) critique of the BSC by applying the concepts developed therein to contemporary research on the BSC and to the development of practice in performance measurement. The analysis is of relevance for many companies in the Asia-Pacific area as an increasing numbers...

  10. APPROXIMATIONS TO PERFORMANCE MEASURES IN QUEUING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Kambo, N. S.

    2012-11-01

    Full Text Available Approximations to various performance measures in queuing systems have received considerable attention because these measures have wide applicability. In this paper we propose two methods to approximate the queuing characteristics of a GI/M/1 system. The first method is non-parametric in nature, using only the first three moments of the arrival distribution. The second method treads the known path of approximating the arrival distribution by a mixture of two exponential distributions by matching the first three moments. Numerical examples and optimal analysis of performance measures of GI/M/1 queues are provided to illustrate the efficacy of the methods, and are compared with benchmark approximations.

  11. Facility for the evaluation of space communications and related systems

    Science.gov (United States)

    Kerczewski, Robert J.; Svoboda, James S.; Kachmar, Brian A.

    1995-01-01

    NASA Lewis Research Center's Communications Projects Branch has developed a facility for the evaluation of space communications systems and related types of systems, called the Advanced Space Communications (ASC) Laboratory. The ASC Lab includes instrumentation, testbed hardware, and experiment control and monitor software for the evaluation of components, subsystems, systems, and networks. The ASC lab has capabilities to perform radiofrequency (RF), microwave, and millimeter-wave characterizations as well as measurements using low, medium, or high data rate digital signals. In addition to laboratory measurements, the ASC Lab also includes integrated satellite ground terminals allowing experimentation and measurements accessing operational satellites through real space links.

  12. Economic evaluation of occupational safety preventive measures in a hospital.

    Science.gov (United States)

    Ramos, Delfina G; Arezes, Pedro M; Afonso, Paulo

    2015-01-01

    When an organization performs an integrated analysis of risks through its Occupational Health and Safety Management System, several steps are suggested to address the implications of the identified risks. Namely, the organization should make a detailed analysis of the monetary impact for the organization of each of the preventive measures considered. However, it is also important to perform an analysis of the impact of each measure on society (externalities). The aim of this paper is to present a case study related to the application of the proposed economic evaluation methodology. An analysis of the work accidents in a hospital has been made. Three of the major types of accidents have been selected: needle stings, falls and excessive strain. Following the risk assessment, some preventive measures have been designed. Subsequently, the Benefit/Cost ratio (B/C) of these measures has been calculated, both in financial terms (from the organization's perspective) and in economic terms (including the benefits for the worker and for the Society). While the financial ratio is only advantageous in some cases, when the externalities are taken into account, the B/C ratio increases significantly. It is important to consider external benefits to make decisions concerning the implementation of preventive measures in Occupational Health and Safety projects.

  13. Performance Evaluation Of Behavioral Biometric Systems

    OpenAIRE

    Cherifi , Fouad; Hemery , Baptiste; Giot , Romain; Pasquet , Marc; Rosenberger , Christophe

    2009-01-01

    We present in this chapter an overview of techniques for the performance evaluation of behavioral biometric systems. The BioAPI standard that defines the architecture of a biometric system is presented in the first part of the chapter... The general methodology for the evaluation of biometric systems is given including statistical metrics, definition of benchmark databases and subjective evaluation. These considerations rely with the ISO/IEC19795-1 standard describing the biometric performanc...

  14. NKS MOMS. Final report. [Mobile Measurement Systems

    Energy Technology Data Exchange (ETDEWEB)

    Nilssen, J. [Norwegian Radiation Protection Authority (NRPA) (Norway); Aage, H.K. [Danish Emergency Management Agency (DEMA) (Denmark); Palsson, S.E. [Icelandic Radiation Safety Authority (IRSA) (Iceland)

    2013-02-15

    Mobile car-borne measurement systems are an important asset in early phase emergency response in all Nordic countries. However, through the development of the systems in the different countries, there are considerable differences between the systems developed. This complicates Nordic cooperation and mutual assistance in emergency situations. This project aimed to facilitate harmonization of mobile measurement systems between the Nordic countries. The project focused on harmonizing data formats, information exchange and measurement strategies. Although the work done was funded by each member, the project established a good platform for cooperation which will hopefully continue beyond the scope of the project. A two-day seminar was held in May 2012, where all participants presented the current status (equipment, methods used etc.), in addition to invited speakers presenting development within the field of mobile detection and in situ measurements. Exchange of experiences and information on different measurement systems and practises in use was an important part of the seminar. The seminar was followed up by a small workshop during the REFOX exercise in Lund, Sweden, September 2012. Exchange of measurement data from the exercise was facilitated through a workspace proveded by NRPA as part of the MOMS project. The work done in this project will be presented at the NordEx12 seminar in March 2013. (Author)

  15. Evaluating safety management system implementation

    International Nuclear Information System (INIS)

    Preuss, M.

    2009-01-01

    Canada is committed to not only maintaining, but also improving upon our record of having one of the safest aviation systems in the world. The development, implementation and maintenance of safety management systems is a significant step towards improving safety performance. Canada is considered a world leader in this area and we are fully engaged in implementation. By integrating risk management systems and business practices, the aviation industry stands to gain better safety performance with less regulatory intervention. These are important steps towards improving safety and enhancing the public's confidence in the safety of Canada's aviation system. (author)

  16. Image processing system for flow pattern measurements

    International Nuclear Information System (INIS)

    Ushijima, Satoru; Miyanaga, Yoichi; Takeda, Hirofumi

    1989-01-01

    This paper describes the development and application of an image processing system for measurements of flow patterns occuring in natural circulation water flows. In this method, the motions of particles scattered in the flow are visualized by a laser light slit and they are recorded on normal video tapes. These image data are converted to digital data with an image processor and then transfered to a large computer. The center points and pathlines of the particle images are numerically analized, and velocity vectors are obtained with these results. In this image processing system, velocity vectors in a vertical plane are measured simultaneously, so that the two dimensional behaviors of various eddies, with low velocity and complicated flow patterns usually observed in natural circulation flows, can be determined almost quantitatively. The measured flow patterns, which were obtained from natural circulation flow experiments, agreed with photographs of the particle movements, and the validity of this measuring system was confirmed in this study. (author)

  17. Multichannel simultaneous magnetic induction measurement system (MUSIMITOS)

    International Nuclear Information System (INIS)

    Steffen, Matthias; Leonhardt, Steffen; Heimann, Konrad; Bernstein, Nina

    2008-01-01

    Non-contact heart and lung activity monitoring would be a desirable supplement to conventional monitoring techniques. Based on the potential of non-contact magnetic induction measurements, requirements for an adequate monitoring system were estimated. This formed the basis for the development of the presented extendable multichannel simultaneous magnetic induction measurement system (MUSIMITOS). Special focus was given to the dynamic behaviour and simultaneous multichannel measurements, so that the system allows for up to 14 receiver coils working simultaneously at 6 excitation frequencies. Moreover, a real-time software concept for online signal processing visualization in combination with a fast software demodulation is presented. Finally, first steps towards a clinical application are pointed out and technical performance as well as first in vivo measurements are presented. This paper covers some aspects previously presented in Steffen and Leonhardt (2007 Proc. 13th Int. Conf. on Electrical Bioimpedance and the 8th Conf. on Electrical Impedance Tomography, Graz 2007)

  18. Radioactivity measurement in Austria 1992 and 1993. Data and evaluation

    International Nuclear Information System (INIS)

    Bobek, E.

    1995-01-01

    The Federal Ministry of Health and Consumer Protection is responsible for the large scale surveillance of radioactive contaminations of the Austrian territory. For this purpose on one hand an on-line measurement system has been set up, using gamma dose rate measuring devices situated in 336 locations. On the other hand, various media e.g. aerosols, precipitation, surface water and foodstuffs are being collected. Their radionuclide content is analysed in several laboratories. Additional special projects have been set up to improve the knowledge of the time dependence respectively of regional aspects of the contamination situation. The report covers the results of this surveillance for the years 1992 and 1993. The evaluation of these measurements and of other data concerning the average exposure of the Austrian population for the year 1993 is summarized in the following figure. It can be seen that the main contributions to the radiation dose are due to natural exposure pathways, among which the inhalation of indoor radon is of main importance. (Compared to the data in earlier reports due to a new evaluation of the radon risk by ICRP this dose contribution is significantly lower.) In comparison, the component due to the consequences of the Chernobyl reactor accident in 1986 onto Austrian territory during 1992 and 1993 was marginal. (author)

  19. Measurement-Based Performance Evaluation of Advanced MIMO Transceiver Designs

    Directory of Open Access Journals (Sweden)

    Schneider Christian

    2005-01-01

    Full Text Available This paper describes the methodology and the results of performance investigations on a multiple-input multiple-output (MIMO transceiver scheme for frequency-selective radio channels. The method relies on offline simulations and employs real-time MIMO channel sounder measurement data to ensure a realistic channel modeling. Thus it can be classified in between the performance evaluation using some predefined channel models and the evaluation of a prototype hardware in field experiments. New aspects for the simulation setup are discussed, which are frequently ignored when using simpler model-based evaluations. Example simulations are provided for an iterative ("turbo" MIMO equalizer concept. The dependency of the achievable bit error rate performance on the propagation characteristics and on the variation in some system design parameters is shown, whereas the antenna constellation is of particular concern for MIMO systems. Although in many of the considered constellations turbo MIMO equalization appears feasible in real field scenarios, there exist cases with poor performance as well, indicating that in practical applications link adaptation of the transmitter and receiver processing to the environment is necessary.

  20. Linear systems a measurement based approach

    CERN Document Server

    Bhattacharyya, S P; Mohsenizadeh, D N

    2014-01-01

    This brief presents recent results obtained on the analysis, synthesis and design of systems described by linear equations. It is well known that linear equations arise in most branches of science and engineering as well as social, biological and economic systems. The novelty of this approach is that no models of the system are assumed to be available, nor are they required. Instead, a few measurements made on the system can be processed strategically to directly extract design values that meet specifications without constructing a model of the system, implicitly or explicitly. These new concepts are illustrated by applying them to linear DC and AC circuits, mechanical, civil and hydraulic systems, signal flow block diagrams and control systems. These applications are preliminary and suggest many open problems. The results presented in this brief are the latest effort in this direction and the authors hope these will lead to attractive alternatives to model-based design of engineering and other systems.

  1. A Critique of Health System Performance Measurement.

    Science.gov (United States)

    Lynch, Thomas

    2015-01-01

    Health system performance measurement is a ubiquitous phenomenon. Many authors have identified multiple methodological and substantive problems with performance measurement practices. Despite the validity of these criticisms and their cross-national character, the practice of health system performance measurement persists. Theodore Marmor suggests that performance measurement invokes an "incantatory response" wrapped within "linguistic muddle." In this article, I expand upon Marmor's insights using Pierre Bourdieu's theoretical framework to suggest that, far from an aberration, the "linguistic muddle" identified by Marmor is an indicator of a broad struggle about the representation and classification of public health services as a public good. I present a case study of performance measurement from Alberta, Canada, examining how this representational struggle occurs and what the stakes are. © The Author(s) 2015.

  2. IBM PC/IX operating system evaluation plan

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Granier, Martin; Hall, Philip P.; Triantafyllopoulos, Spiros

    1984-01-01

    An evaluation plan for the IBM PC/IX Operating System designed for IBM PC/XT computers is discussed. The evaluation plan covers the areas of performance measurement and evaluation, software facilities available, man-machine interface considerations, networking, and the suitability of PC/IX as a development environment within the University of Southwestern Louisiana NASA PC Research and Development project. In order to compare and evaluate the PC/IX system, comparisons with other available UNIX-based systems are also included.

  3. Measuring weld heat to evaluate weld integrity

    Energy Technology Data Exchange (ETDEWEB)

    Schauder, V., E-mail: schauder@hks-prozesstechnik.de [HKS-Prozesstechnik GmbH, Halle (Germany)

    2015-11-15

    Eddy current and ultrasonic testing are suitable for tube and pipe mills and have been used for weld seam flaw detection for decades, but a new process, thermography, is an alternative. By measuring the heat signature of the weld seam as it cools, it provides information about weld integrity at and below the surface. The thermal processes used to join metals, such as plasma, induction, laser, and gas tungsten arc welding (GTAW), have improved since they were developed, and they get better with each passing year. However, no industrial process is perfect, so companies that conduct research in flaw detection likewise continue to develop and improve the technologies used to verify weld integrity: ultrasonic testing (UT), eddy current testing (ET), hydrostatic, X-ray, magnetic particle, and liquid penetrant are among the most common. Two of these are used for verifying the integrity of the continuous welds such as those used on pipe and tube mills: UT and ET. Each uses a transmitter to send waves of ultrasonic energy or electrical current through the material and a receiver (probe) to detect disturbances in the flow. The two processes often are combined to capitalize on the strengths of each. While ET is good at detecting flaws at or near the surface, UT penetrates the material, detecting subsurface flaws. One drawback is that sound waves and electrical current waves have a specific direction of travel, or an alignment. A linear defect that runs parallel to the direction of travel of the ultrasonic sound wave or a flaw that is parallel to the coil winding direction of the ET probe can go undetected. A second drawback is that they don't detect cold welds. An alternative process, thermography, works in a different fashion: It monitors the heat of the material as the weld cools. Although it measures the heat at the surface, the heat signature provides clues about cooling activity deep in the material, resulting in a thorough assessment of the weld's integrity It

  4. eHealth System for Collecting and Utilizing Patient Reported Outcome Measures for Personalized Treatment and Care (PROMPT-Care) Among Cancer Patients: Mixed Methods Approach to Evaluate Feasibility and Acceptability.

    Science.gov (United States)

    Girgis, Afaf; Durcinoska, Ivana; Levesque, Janelle V; Gerges, Martha; Sandell, Tiffany; Arnold, Anthony; Delaney, Geoff P

    2017-10-02

    Despite accumulating evidence indicating that collecting patient-reported outcomes (PROs) and transferring results to the treating health professional in real time has the potential to improve patient well-being and cancer outcomes, this practice is not widespread. The aim of this study was to test the feasibility and acceptability of PROMPT-Care (Patient Reported Outcome Measures for Personalized Treatment and Care), a newly developed electronic health (eHealth) system that facilitates PRO data capture from cancer patients, data linkage and retrieval to support clinical decisions and patient self-management, and data retrieval to support ongoing evaluation and innovative research. We developed an eHealth system in consultation with content-specific expert advisory groups and tested it with patients receiving treatment or follow-up care in two hospitals in New South Wales, Australia, over a 3-month period. Participants were recruited in clinic and completed self-report Web-based assessments either just before their upcoming clinical consultation or every 4 weeks if in follow-up care. A mixed methods approach was used to evaluate feasibility and acceptability of PROMPT-Care; data collected throughout the study informed the accuracy and completeness of data transfer procedures, and extent of missing data was determined from participants' assessments. Patients participated in cognitive interviews while completing their first assessment and completed evaluation surveys and interviews at study-end to assess system acceptability and usefulness of patient self-management resources, and oncology staff were interviewed at study-end to determine the acceptability and perceived usefulness of real-time PRO reporting. A total of 42 patients consented to the study; 7 patients were withdrawn before starting the intervention primarily because of changes in eligibility. Overall, 35 patients (13 on treatment and 22 in follow-up) completed 67 assessments during the study period. Mean

  5. Evaluating a Skills Management System

    International Nuclear Information System (INIS)

    Largier, A.

    2013-01-01

    In order to anticipate the large number of people due to retire in the next few years, and to optimize the workforce contribution, IRSN (Institute for radiation protection and nuclear safety) is setting up skill management. This poster presents the IRSN's skill management system. The skill management system is based on a 4 step approach: -) identifying and listing the necessary skills, -) assessing the skills available, -) defining and setting up solutions: training, recruitment, out-sourcing), and -) feedback about the efficiency of the system. It appears that it is important to take into account the way the organization considers individual ability in order to favour collective proficiency

  6. Academic Digital Library Construction Evaluation: Measures and Approaches

    OpenAIRE

    Wang , Qiyun

    2008-01-01

    Through review norms, standards and practice related to academic digital library construction evaluation at home and abroad, on the basis of investigation and study on the digital library evaluation at home and abroad, for status quo of the academic digital library construction, using qualitative analysis and quantitative analysis method, with methods and indicators for the traditional library evaluation system as a reference coordinates, put forward a comprehensive evaluation index system of...

  7. Adversary characterization for security system evaluation

    International Nuclear Information System (INIS)

    Suber, L.A. Jr.

    1976-04-01

    Evaluation of security systems effectiveness requires a definition of adversary capabilities, but an objective basis for such a definition has been lacking. A system of adversary attributes is proposed in which any desired adversary may be synthesized by selection of the appropriate level of capability from each attribute or category. In use, the synthesized adversaries will be pitted against a security system in an evaluation model, thus allowing comparison of other adversary or security system configurations

  8. Modular system design and evaluation

    CERN Document Server

    Levin, Mark Sh

    2015-01-01

    This book examines seven key combinatorial engineering frameworks (composite schemes consisting of algorithms and/or interactive procedures) for hierarchical modular (composite) systems. These frameworks are based on combinatorial optimization problems (e.g., knapsack problem, multiple choice problem, assignment problem, morphological clique problem), with the author’s version of morphological design approach – Hierarchical Morphological Multicritieria Design (HMMD) – providing a conceptual lens with which to elucidate the examples discussed. This approach is based on ordinal estimates of design alternatives for systems parts/components, however, the book also puts forward an original version of HMMD that is based on new interval multiset estimates for the design alternatives with special attention paid to the aggregation of modular solutions (system versions). The second part of ‘Modular System Design and Evaluation’ provides ten information technology case studies that enriches understanding of th...

  9. Measurability and Safety Verification for Stochastic Hybrid Systems

    DEFF Research Database (Denmark)

    Fränzle, Martin; Hahn, Ernst Moritz; Hermanns, Holger

    2011-01-01

    method that establishes safe upper bounds on reachability probabilities. To arrive there requires us to solve semantic intricacies as well as practical problems. In particular, we show that measurability of a complete system follows from the measurability of its constituent parts. On the practical side......-time behaviour is given by differential equations, as for usual hybrid systems, but the targets of discrete jumps are chosen by probability distributions. These distributions may be general measures on state sets. Also non-determinism is supported, and the latter is exploited in an abstraction and evaluation...

  10. Magnetic Field Response Measurement Acquisition System

    Science.gov (United States)

    Woodard, Stanley E.; Taylor,Bryant D.; Shams, Qamar A.; Fox, Robert L.

    2007-01-01

    This paper presents a measurement acquisition method that alleviates many shortcomings of traditional measurement systems. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. Wire degradation has resulted in aircraft fatalities and critical space launches being delayed. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. Power is wirelessly provided to the sensing element by using Faraday induction. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response frequency, resistance and amplitude has been developed and is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. The method does not require the sensors to be near the acquisition hardware. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed. Examples of magnetic field response sensors and the respective measurement characterizations are presented. Implementation of this method on an aerospace system is discussed.

  11. Dependability Evaluation of Advanced Diverse Protection System

    International Nuclear Information System (INIS)

    Oh, Yang Gyun; Lee, Yoon Hee; Sohn, Se Do; Baek, Seung Min; Lee, Sang Jeong

    2014-01-01

    For the mitigation of anticipated transients without scram (ATWS) as well as common cause failure (CCF) within the plant protection system (PPS) and the emergency safety feature . component control system (ESF-CCS), the diverse protection system (DPS) has been designed by KEPCO Engineering and Construction Company. Recently KEPCO E and C has developed the advanced diverse protection system (ADPS), which has four redundant channels, in an attempt to enhance a fault-tolerant capability of the system. For the evaluation of overall system improvement effects of the ADPS compared with the DPS, the dependability evaluation results are described herein. For all dependability attributes, this paper suggests a practical dependability evaluation method which uses quantitative dependability scores and indices. An overall dependability evaluation index (DEI) for the ADPS is evaluated with the average value of reliability/ security/maintainability/safety indices (i.e., RID, SID, MID, and SID') for dependability. The evaluation results show that the DEI value of ADPS can be improved by approximately 23% compared with that of the DPS, thanks to its fault-tolerant system architecture, software design changes, and external interface design features. Several suggestions have been made, in this paper, of an overall quantitative dependability evaluation method for the nuclear instrumentation and control (I and C) systems including the DPS and ADPS, and the usefulness of dependability evaluation on nuclear I and C systems has been confirmed

  12. Coordinate metrology accuracy of systems and measurements

    CERN Document Server

    Sładek, Jerzy A

    2016-01-01

    This book focuses on effective methods for assessing the accuracy of both coordinate measuring systems and coordinate measurements. It mainly reports on original research work conducted by Sladek’s team at Cracow University of Technology’s Laboratory of Coordinate Metrology. The book describes the implementation of different methods, including artificial neural networks, the Matrix Method, the Monte Carlo method and the virtual CMM (Coordinate Measuring Machine), and demonstrates how these methods can be effectively used in practice to gauge the accuracy of coordinate measurements. Moreover, the book includes an introduction to the theory of measurement uncertainty and to key techniques for assessing measurement accuracy. All methods and tools are presented in detail, using suitable mathematical formulations and illustrated with numerous examples. The book fills an important gap in the literature, providing readers with an advanced text on a topic that has been rapidly developing in recent years. The book...

  13. Development of film dosimetric measurement system for verification of RTP

    International Nuclear Information System (INIS)

    Chen Yong; Bao Shanglian; Ji Changguo; Zhang Xin; Wu Hao; Han Shukui; Xiao Guiping

    2007-01-01

    Objective: To develop a novel film dosimetry system based on general laser scanner in order to verify patient-specific Radiotherapy Treatment Plan(RTP) in three-Dimensional Adaptable Radiotherapy(3D ART) and Intensity Modulated Radiotherapy (IMRT). Methods: Some advanced methods, including film saturated development, wavelet filtering with multi-resolution thresholds and discrete Fourier reconstruction are employed in this system to reduce artifacts, noise and distortion induced by film digitizing with general scanner; a set of coefficients derived from Monte Carlo(MC) simulation are adopted to correct the film over-response to low energy scattering photons; a set of newly emerging criteria, including γ index and Normalized Agreement Test (NAT) method, are employed to quantitatively evaluate agreement of 2D dose distributions between the results measured by the films and calculated by Treatment Planning System(TPS), so as to obtain straightforward presentations, displays and results with high accuracy and reliability. Results: Radiotherapy doses measured by developed system agree within 2% with those measured by ionization chamber and VeriSoft Film Dosimetry System, and quantitative evaluation indexes are within 3%. Conclusions: The developed system can be used to accurately measure the radiotherapy dose and reliably make quantitative evaluation for RTP dose verification. (authors)

  14. Handbook on Measurement, Assessment, and Evaluation in Higher Education

    Science.gov (United States)

    Secolsky, Charles, Ed.; Denison, D. Brian, Ed.

    2011-01-01

    Increased demands for colleges and universities to engage in outcomes assessment for accountability purposes have accelerated the need to bridge the gap between higher education practice and the fields of measurement, assessment, and evaluation. The "Handbook on Measurement, Assessment, and Evaluation in Higher Education" provides higher…

  15. Diagnostic and Measuring Systems of the Power Transformers

    Directory of Open Access Journals (Sweden)

    Jan Michalik

    2003-01-01

    Full Text Available In the article the diagnostic and measuring systems dedicated for complex output tests of power transformers aswell as their diagnostic is dcscribcd. The aim of research in this area was to elaborate the problem of so-called open loop measuring system controlled by PC. The attribute "open" means the possibility to adapt the system for different electric equipment, different measurands and an zdaptation of the way of monitoring, evaluation and distribution of output information according to specific requirements the controlled transformer.

  16. Road Anomalies Detection System Evaluation.

    Science.gov (United States)

    Silva, Nuno; Shah, Vaibhav; Soares, João; Rodrigues, Helena

    2018-06-21

    Anomalies on road pavement cause discomfort to drivers and passengers, and may cause mechanical failure or even accidents. Governments spend millions of Euros every year on road maintenance, often causing traffic jams and congestion on urban roads on a daily basis. This paper analyses the difference between the deployment of a road anomalies detection and identification system in a “conditioned” and a real world setup, where the system performed worse compared to the “conditioned” setup. It also presents a system performance analysis based on the analysis of the training data sets; on the analysis of the attributes complexity, through the application of PCA techniques; and on the analysis of the attributes in the context of each anomaly type, using acceleration standard deviation attributes to observe how different anomalies classes are distributed in the Cartesian coordinates system. Overall, in this paper, we describe the main insights on road anomalies detection challenges to support the design and deployment of a new iteration of our system towards the deployment of a road anomaly detection service to provide information about roads condition to drivers and government entities.

  17. Using Expert Systems in Evaluation of the State of High Voltage Machine Insulation Systems

    Directory of Open Access Journals (Sweden)

    K. Záliš

    2000-01-01

    Full Text Available Expert systems are used for evaluating the actual state and future behavior of insulating systems of high voltage electrical machines and equipment. Several rule-based expert systems have been developed in cooperation with top diagnostic workplaces in the Czech Republic for this purpose. The IZOLEX expert system evaluates diagnostic measurement data from commonly used offline diagnostic methods for the diagnostic of high voltage insulation of rotating machines, non-rotating machines and insulating oils. The CVEX expert system evaluates the discharge activity on high voltage electrical machines and equipment by means of an off-line measurement. The CVEXON expert system is for evaluating the discharge activity by on-line measurement, and the ALTONEX expert system is the expert system for on-line monitoring of rotating machines. These developed expert systems are also used for educating students (in bachelor, master and post-graduate studies and in courses which are organized for practicing engineers and technicians and for specialists in the electrical power engineering branch. A complex project has recently been set up to evaluate the measurement of partial discharges. Two parallel expert systems for evaluating partial dischatge activity on high voltage electrical machines will work at the same time in this complex evaluating system.

  18. Differential Measurement Periodontal Structures Mapping System

    Science.gov (United States)

    Companion, John A. (Inventor)

    1998-01-01

    This invention relates to a periodontal structure mapping system employing a dental handpiece containing first and second acoustic sensors for locating the Cemento-Enamel Junction (CEJ) and measuring the differential depth between the CEJ and the bottom of the periodontal pocket. Measurements are taken at multiple locations on each tooth of a patient, observed, analyzed by an optical analysis subsystem, and archived by a data storage system for subsequent study and comparison with previous and subsequent measurements. Ultrasonic transducers for the first and second acoustic sensors are contained within the handpiece and in connection with a control computer. Pressurized water is provided for the depth measurement sensor and a linearly movable probe sensor serves as the sensor for the CEJ finder. The linear movement of the CEJ sensor is obtained by a control computer actuated by the prober. In an alternate embodiment, the CEJ probe is an optical fiber sensor with appropriate analysis structure provided therefor.

  19. The Transportable Measurements Facility (TMF) System Description.

    Science.gov (United States)

    1980-05-23

    sites using different antennas, antenna/site characterization, ATCRBS-mode and DABS-mode processor evaluation, and DABS-based ATC and ATARS system...conditions met. 34 TABLE 3 TMF DATA RECORDED DURING EXPERIMENTS By Word Type 1) By Parameter Word No. of Bits Experiment Number 8 Physical Location Number of

  20. A portable nondestructive assay measurement control system

    International Nuclear Information System (INIS)

    Palmer, M.E.

    1984-01-01

    Portable nondestructive assay (NDA) of plutonium processing hoods, solvent extraction columns, glove boxes, filters, and other items is required for both nuclear materials accountability and criticality control purposes. The Plutonium Finishing Plant has hundreds of such items that require routine portable NDA measurement. Previous recordkeeping of NDA measurements consisted of boxes of papers containing results and notebooks containing notes for each item to be measured. If the notes for any item were lost, new measurement parameters had to be calculated for that item. As a result, subsequent measurements could no longer be directly compared with previous results for that item due to possible changes in measurement parameters. The new portable NDA management system keeps all the necessary information in a computerized data base. Technicians are provided with a computer-generated drawing of each item to be measured, which also contains comments, measurement points, measurement parameters, and a form for filling in the raw data. After the measurements are made, the technician uses the computer to calculate and print out the results

  1. Eddy Correlation Flux Measurement System Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Cook, D. R. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-01-01

    The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO2) (and methane at one Southern Great Plains extended facility (SGP EF) and the North Slope of Alaska Central Facility (NSA CF). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO2 concentration. The instruments used are: • a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature) • an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO2 concentration, and • an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at one SGP EF and at the NSA CF. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A Surface Energy Balance System (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), ARM Mobile Facility 1 (AMF1), and ARM Mobile Facility 2 (AMF2). The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. The SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes. The SEBS at one SGP and one NSA site also support upwelling and downwelling PAR measurements to qualify those two locations as Ameriflux sites.

  2. Corrective measures evaluation report for Tijeras Arroyo groundwater.

    Energy Technology Data Exchange (ETDEWEB)

    Witt, Johnathan L (North Wind, Inc., Idaho Falls, ID); Orr, Brennon R. (North Wind, Inc., Idaho Falls, ID); Dettmers, Dana L. (North Wind, Inc., Idaho Falls, ID); Hall, Kevin A. (North Wind, Inc., Idaho Falls, ID); Howard, M. Hope (North Wind, Inc., Idaho Falls, ID)

    2005-08-01

    This Corrective Measures Evaluation report was prepared as directed by a Compliance Order on Consent issued by the New Mexico Environment Department to document the process of selecting the preferred remedial alternative for Tijeras Arroyo Groundwater. Supporting information includes background concerning the site conditions and potential receptors and an overview of work performed during the Corrective Measures Evaluation. The evaluation of remedial alternatives included identifying and describing four remedial alternatives, an overview of the evaluation criteria and approach, comparing remedial alternatives to the criteria, and selecting the preferred remedial alternative. As a result of the Corrective Measures Evaluation, monitored natural attenuation of the contaminants of concern (trichloroethene and nitrate) is the preferred remedial alternative for implementation as the corrective measure for Tijeras Arroyo Groundwater. Design criteria to meet cleanup goals and objectives and the corrective measures implementation schedule for the preferred remedial alternative are also presented.

  3. UNIX-based operating systems robustness evaluation

    Science.gov (United States)

    Chang, Yu-Ming

    1996-01-01

    Robust operating systems are required for reliable computing. Techniques for robustness evaluation of operating systems not only enhance the understanding of the reliability of computer systems, but also provide valuable feed- back to system designers. This thesis presents results from robustness evaluation experiments on five UNIX-based operating systems, which include Digital Equipment's OSF/l, Hewlett Packard's HP-UX, Sun Microsystems' Solaris and SunOS, and Silicon Graphics' IRIX. Three sets of experiments were performed. The methodology for evaluation tested (1) the exception handling mechanism, (2) system resource management, and (3) system capacity under high workload stress. An exception generator was used to evaluate the exception handling mechanism of the operating systems. Results included exit status of the exception generator and the system state. Resource management techniques used by individual operating systems were tested using programs designed to usurp system resources such as physical memory and process slots. Finally, the workload stress testing evaluated the effect of the workload on system performance by running a synthetic workload and recording the response time of local and remote user requests. Moderate to severe performance degradations were observed on the systems under stress.

  4. Development of a School Leadership Evaluation System

    Science.gov (United States)

    Orlando, Nik

    2014-01-01

    This action research study examined the effectiveness of the process implemented by Partnerships to Uplift Communities (PUC) Schools Charter Management Organization to develop their school leader evaluation system in collaboration with current PUC school leaders. The development of the leadership evaluation system included the collective voices of…

  5. IDEA: A Unifying Theory for Evaluation Systems

    DEFF Research Database (Denmark)

    Bella, Giampaolo; Giustolisi, Rosario

    2017-01-01

    Secure systems for voting, exams, auctions and conference paper management are theorised to address the same problem, that of secure evaluations. In support of such a unifying theory comes a model for Secure Evaluation Systems (SES), which offers innovative common grounds to understand all four...

  6. Intelligent nuclear measuring system for multi detectors

    International Nuclear Information System (INIS)

    Gujgiczer, A.; Solymosi, J.; Zsille, O.; Illes, Z.; Barnabas, I.; Ranga, T.; Lakatos, T.

    1998-01-01

    The measuring system can be used for recording gamma spectra and/or experimental beta-dispersion. Several environmental samples can be examined simultaneously, and the instrument can be used in the laboratory or in the field. Low cost multichannel analyzers using NaI(Tl) or plastic scintillators are interfaced to an IBM PC/AT, which controls the measurement, data processing, and data transmission and archiving. (M.D.)

  7. High temperature hall effect measurement system design, measurement and analysis

    Science.gov (United States)

    Berkun, Isil

    A reliable knowledge of the transport properties of semiconductor materials is essential for the development and understanding of a number of electronic devices. In this thesis, the work on developing a Hall Effect measurement system with software based data acqui- sition and control for a temperature range of 300K-700K will be described. A system was developed for high temperature measurements of materials including single crystal diamond, poly-crystalline diamond, and thermoelectric compounds. An added capability for monitor- ing the current versus voltage behavior of the contacts was used for studying the influence of ohmic and non-ohmic contacts on Hall Effect measurements. The system has been primar- ily used for testing the transport properties of boron-doped single crystal diamond (SCD) deposited in a microwave plasma-assisted chemical vapor deposition (MPCVD) reactor [1]. Diamond has several outstanding properties that are of high interest for its development as an electronic material. These include a relatively wide band gap of 5.5 (eV), high thermal conductivity, high mobility, high saturation velocity, and a high breakdown voltage. For a temperature range of 300K-700K, IV curves, Hall mobilities and carrier concentrations are shown. Temperature dependent Hall effect measurements have shown carrier concentrations from below 1017cm --3 to approximately 1021 cm--3 with mobilities ranging from 763( cm2/V s) to 0.15(cm 2/V s) respectively. Simulation results have shown the effects of single and mixed carrier models, activation energies, effective mass and doping concentrations. These studies have been helpful in the development of single crystal diamond for diode applications. Reference materials of Ge and GaAs were used to test the Hall Effect system. The system was also used to characterize polycrystalline diamond deposited on glass for electrochemical applications, and Mg2(Si,Sn) compounds which are promising candidates of low-cost, light weight and non

  8. An USB-based time measurement system

    International Nuclear Information System (INIS)

    Qin Xi; Liu Shubin; An Qi

    2010-01-01

    In this paper,we report the electronics of a timing measurement system of PTB(portable TDC board), which is a handy tool based on USB interface, customized for high precision time measurements without any crates. The time digitization is based on the High Performance TDC Chip (HPTDC). The real-time compensation for HPTDC outputs and the USB master logic are implemented in an ALTERA's Cyclone FPGA. The architecture design and logic design are described in detail. Test of the system showed a time resolution of 13.3 ps. (authors)

  9. Size and velocity measurements in combustion systems

    International Nuclear Information System (INIS)

    Levy, Y.; Timnat, Y.M.

    1986-01-01

    Two-phase flow measurements for size and velocity determination in combustion systems are discussed: the pedestal technique and phase Doppler anemometry (PDA) are described in detail. The experimental apparatus for the pedestal method includes the optical laser-Doppler anemometry (LDA) package and the electronic data acquisition system. The latter comprises three channels for recording the Doppler frequency, and the pedestal amplitude as well as the validation pulse. Results of measurements performed in a dump combustor, into which kerosene droplets were injected, are presented. The principle of the PDA technique is explained and validation experiments, using latex particles, are reported. Finally the two methods are compared

  10. Solar Thermal System Evaluation in China

    Directory of Open Access Journals (Sweden)

    Xinyu Zhang

    2015-01-01

    Full Text Available More than 581 solar thermal systems (STSs, 98 counties, and 47 renewable application demonstration cites in China need to be inspected by the end of 2015. In this study, the baseline for performance and economic evaluation of STSs are presented based on the site test data and related references. An index used to evaluate STSs was selected, and methods to acquire the parameters used to calculate the related index were set. The requirements for sensors for testing were specified. The evaluation method was applied to three systems and the result shows that the evaluation method is suitable for the evaluation of STSs in China.

  11. Task oriented evaluation system for maintenance robots

    International Nuclear Information System (INIS)

    Asame, Hajime; Endo, Isao; Kotosaka, Shin-ya; Takata, Shozo; Hiraoka, Hiroyuki; Kohda, Takehisa; Matsumoto, Akihiro; Yamagishi, Kiichiro.

    1994-01-01

    The adaptability evaluation of maintenance robots to autonomous plants has been discussed. In this paper, a new concept of autonomous plant with maintenance robots are introduced, and a framework of autonomous maintenance system is proposed. Then, task-oriented evaluation of robot arms is discussed for evaluating their adaptability to maintenance tasks, and a new criterion called operability is proposed for adaptability evaluation. The task-oriented evaluation system is implemented and applied to structural design of robot arms. Using genetic algorithm, an optimal structure adaptable to a pump disassembly task is obtained. (author)

  12. Magnetization measurement of niobium for superconducting cavity material evaluation

    International Nuclear Information System (INIS)

    Wake, Masayoshi; Saito, Kenji.

    1995-05-01

    A series of magnetization measurements on niobium materials for superconducting cavities was performed, and the method was found to be very useful for material evaluation. The effects of annealing, chemical polishing and machining were clearly observed by this method. The material quality and the processing of the material can be properly evaluated by measuring the magnetization. An observation of the Q-disease effect indicates the possibility of using this method for the studies beyond material evaluation. (J.P.N)

  13. Walking beam pumping unit system efficiency measurements

    International Nuclear Information System (INIS)

    Kilgore, J.J.; Tripp, H.A.; Hunt, C.L. Jr.

    1991-01-01

    The cost of electricity used by walking beam pumping units is a major expense in producing crude oil. However, only very limited information is available on the efficiency of beam pumping systems and less is known about the efficiency of the various components of the pumping units. This paper presents and discusses measurements that have been made on wells at several Shell locations and on a specially designed walking beam pump test stand at Lufkin Industries. These measurements were made in order to determine the overall system efficiency and efficiency of individual components. The results of this work show that the overall beam pumping system efficiency is normally between 48 and 58 percent. This is primarily dependent on the motor size, motor type, gearbox size, system's age, production, pump size, tubing size, and rod sizes

  14. Urogenital system diseases's radiological evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, S; Mecozzi, B

    1985-01-01

    Radiological urogenital radiography reliability, can be compromised because of absence of a correct urodynamic diagnosis. It is then required that specialist radiologists know the problems concerning the urogenital system radiographies cannot be made in many cases, because of the scarcity in hospitals of idoneous urodynamic services.

  15. Establishment of nuclear data evaluation system (I)

    International Nuclear Information System (INIS)

    Chang, Jong Hwa; Lee, Chang Kun; Kim, Jeong Do; Kim, Young Sik; Kim, Young Jin; Kim, Hyung Guk; Kil, Chung Sup; Kim, Kang Suk

    1994-08-01

    Nuclear data is fundamental data for development of new type of nuclear, upgrade of nuclear fuel, treatment of radwaste, research on fusion reactor, radioisotope usage, and nuclear medical therapy. Nuclear data is produced with experiments. However rack of experimental data for thousands of nuclides and various reaction types makes it essential to do statistical evaluation and theoretical interpolation. This study is intended to join international cooperation after establishing domestic basis for nuclear data evaluation work. This project is the first year of five year plan to do followings: 1) Establishment of database system to collect experimental data, 2) Setup of computer assistance system for evaluation work, 3) Verification of established system by test evaluation of selected nuclide reaction. The system has a collection of mass data of nuclides, computer codes for test evaluation of total cross section of 0-16 and collection of EXFOR format data for 0-16. This system will be improved continuously on next years. (Author)

  16. Displacement measurement system for linear array detector

    International Nuclear Information System (INIS)

    Zhang Pengchong; Chen Ziyu; Shen Ji

    2011-01-01

    It presents a set of linear displacement measurement system based on encoder. The system includes displacement encoders, optical lens and read out circuit. Displacement read out unit includes linear CCD and its drive circuit, two amplifier circuits, second order Butterworth low-pass filter and the binarization circuit. The coding way is introduced, and various parts of the experimental signal waveforms are given, and finally a linear experimental test results are given. The experimental results are satisfactory. (authors)

  17. Measurement system for SSRF pulsed magnets

    International Nuclear Information System (INIS)

    Peng Chengcheng; Gu Ming; Liu Bo; Ouyang Lianhua

    2007-01-01

    This paper describes the magnetic field measurement system for pulsed magnets in SSRF. The system consists of magnetic probes, analog active integrator, oscilloscope, stepper motor and a controller. An application program based on LabVIEW has been developed as main control unit. After the magnetic field mapping of a septum magnet prototype, it is verified that the test results accord with the results of theoretical calculation and computer simulation. (authors)

  18. An Examination of Organizatinal Performance Measurement System Utilization

    OpenAIRE

    DeBusk, Gerald Kenneth

    2003-01-01

    This dissertation provides results of three studies, which examine the utilization of organizational performance measurement systems. Evidence gathered in the first study provides insight into the number of perspectives or components found in the evaluation of an organization's performance and the relative weight placed on those components. The evidence suggests that the number of performance measurement components and their relative composition is situational. Components depend heavily on th...

  19. Quantum system lifetimes and measurement perturbations

    International Nuclear Information System (INIS)

    Najakov, E.

    1977-05-01

    The recently proposed description of quantum system decay in terms of repeated measurement perturbations is modified. The possibility of retarded reductions to a unique quantum state, due to ineffective localization of the decay products at initial time measurements, is simply taken into account. The exponential decay law is verified again. A modified equation giving the observed lifetime in terms of unperturbed quantum decay law, measurement frequency and reduction law is derived. It predicts deviations of the observed lifetime from the umperturbed one, together with a dependence on experimental procedures. The influence of different model unperturbed decay laws and reduction laws on this effect is studied

  20. Electron cyclotron beam measurement system in the Large Helical Device

    Energy Technology Data Exchange (ETDEWEB)

    Kamio, S., E-mail: kamio@nifs.ac.jp; Takahashi, H.; Kubo, S.; Shimozuma, T.; Yoshimura, Y.; Igami, H.; Ito, S.; Kobayashi, S.; Mizuno, Y.; Okada, K.; Osakabe, M.; Mutoh, T. [National Institute for Fusion Science, Toki 509-5292 (Japan)

    2014-11-15

    In order to evaluate the electron cyclotron (EC) heating power inside the Large Helical Device vacuum vessel and to investigate the physics of the interaction between the EC beam and the plasma, a direct measurement system for the EC beam transmitted through the plasma column was developed. The system consists of an EC beam target plate, which is made of isotropic graphite and faces against the EC beam through the plasma, and an IR camera for measuring the target plate temperature increase by the transmitted EC beam. This system is applicable to the high magnetic field (up to 2.75 T) and plasma density (up to 0.8 × 10{sup 19} m{sup −3}). This system successfully evaluated the transmitted EC beam profile and the refraction.

  1. Measurement of Detector Efficiency for the CZT Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Kang Hwa; Kon, Kang Seo; Kim, Jeongin [KHNP, Radiation Health Research Institute, Seoul (Korea, Republic of)

    2014-05-15

    Evaluation method of using CZT have been being attempted in various places such as AEP(American Electronic Power) etc since EDF(Electricite de France) had apply to the project named 'Source Term Reduction'. CZT can measure source terms on various places in nuclear power plants because it is available at room temperature unless a seperate device and portability is good. Consequently, CZT show good result from analysis of source terms in nuclear power plants. This study found out efficiency of CZT detector that is now researched in CZT Monitoring System for measure source terms on RCS system of domestic old and new nuclear power plants and verified measured efficiency values by comparing to reference efficiency we already know. This study was carried out for finding out detector's efficiency depending on necessary energy in order to save quantitative radioactivity value of source terms. Eventually, this study is to develope CZT Monitoring System measuring CRUD in domestic PWRs primary system or piping system by carrying out in-vivo. Considering error ratio ±20% on radioactivity value of CRM used in measuring and verifying efficiency, measurement of detector Efficiency for the CZT Monitoring System is good. But more various tests is needed than now for an accurate measurement.

  2. Optimized Evaluation System to Athletic Food Safety

    OpenAIRE

    Shanshan Li

    2015-01-01

    This study presented a new method of optimizing evaluation function in athletic food safety information programming by particle swarm optimization. The process of food information evaluation function is to automatically adjust these parameters in the evaluation function by self-optimizing method accomplished through competition, which is a food information system plays against itself with different evaluation functions. The results show that the particle swarm optimization is successfully app...

  3. Evaluating Frequency Quality of Nordic System using PMU data

    DEFF Research Database (Denmark)

    Xu, Zhao; Østergaard, Jacob; Togeby, Mikael

    2008-01-01

    This paper focuses on analysing frequency quality of Nordic power system using measurements from Phasor Measurement Units (PMU). The PMU data of one year long period is used which has very high time resolution (20 ms per sample) and is able to provide detailed information in evaluating frequency...

  4. Contact pressure measurement in hand tool evaluation studies

    NARCIS (Netherlands)

    Kuijt-Evers, L.F.M.; Bosch, T.

    2006-01-01

    In hand tool evaluation studies, several objective measurements are used. Grip force distribution and grip force are important as they give feedback about the force which has to be performed with the hand on the handle. A measurement technique -which is related to grip force measurement- is contact

  5. Evaluating the effects of parking policy measures in nature areas

    NARCIS (Netherlands)

    Beunen, R.; Jaarsma, C.F.; Regnerus, H.D.

    2006-01-01

    Parking policy measures are widely used to manage cars in nature areas. Only with data from long-term monitoring projects is it possible to separate ¿normal¿ fluctuation in the number of cars from fluctuation caused by trends or caused by the effects of these measures. An evaluation of measures

  6. Thermodynamic evaluation of the Cu-Mg-Zr system

    International Nuclear Information System (INIS)

    Haemaelaeinen, M.; Zeng, K.

    1999-01-01

    The thermodynamic evaluation of the Cu-Mg-Zr system is presented in this paper. A literature survey was carried out first based on the most recent literature, which was scanned from the THERMET literature database. The evaluation of the thermodynamic parameters was carried out using Thermo-Calc (version H) software. The evaluation of the Cu-Mg-Zr system was carried out using the most recent experimental data from the literature and a set of DTA measurements. DTA measurements were done using alumina (Al 2 O 3 ) crucibles under helium atmosphere with the niobium (Nb) reference crucible. The evaluated Cu-Mg-Zr phase diagram fitted well with experimental data with the liquidus data in a limited range of composition. There were two miscibility gaps observe in the system. New τ phase was detected using the X-ray and microscopic analysis and the data was used in this evaluation. (orig.)

  7. Characteristics of a simple blackbody measurement system

    International Nuclear Information System (INIS)

    Fu, C.; Anger, N.H.; Kaehms, R.; Jaeger, K.B.

    1988-01-01

    An axially symmetric blackbody (BB) measurement system with a circular aperture and a circular detector is considered. The BB can be of a right circular conical shape, a right cylindrical shape, or a combination of these two shapes. Assuming that the BB is ideal, the power received by the detector is calculated. 8 references

  8. Distance Measures for Information System Reengineering

    NARCIS (Netherlands)

    Poels, G.; Viaene, S.; Dedene, G.; Wangler, B.; Bergman, L.

    2000-01-01

    We present an approach to assess the magnitude and impact of information system reengineering caused by business process change. This approach is based on two concepts: object-oriented business modeling and distance measurement. The former concept is used to visualize changes in the business layer

  9. SIMS: The SLAC Industrial Measurement System

    International Nuclear Information System (INIS)

    Bell, B.

    1990-01-01

    Kern was the first survey company to market an Industrial Measurement System when it released ECDS (Electronic Coordinate Determination System) in the mid-1980s. Originally written for the PDP-11, a version was later released for the PC (ECDS-PC). SLAC purchased this system in 1986 and immediately began to use it for the alignment of the SLC (Stanford Linear Collider). Although ECDS enabled SLAC to perform tasks with a speed never before achieved, they experienced limitations in the software. Since Kern proved unresponsive and SLAC was unable to purchase the source code for any amount of money, they set about writing their own portions of code. They first wrote a system of menus tailored for their specific alignment tasks, and disabled much of the ECDS menu structure. Due to dissatisfaction with the ECDS bundle adjustment program, they wrote their own bundle adjustment in 1988. A further step towarad having their own complete IMS was to develop a data capture program, a task which has been underway since the beginning of this year. They do not yet have data analysis features that are fully integrated, but they do have stand-alone packages that have been written at SLAC. When they first started tinkering with ECDS there was no intention of developing a complete system, but they now have all the elements of such a system - SIMS, the SLAC Industrial Measurement System

  10. Evaluation of Human Prehension Using Grasp Quality Measures

    Directory of Open Access Journals (Sweden)

    Beatriz León

    2012-10-01

    Full Text Available One of the main features of the human hand is its grasping ability. Robot grasping has been studied for years and different quality measures have been proposed to evaluate the stability and manipulability of grasps. Although the human hand is obviously more complex than robot hands, the methods used in robotics might be adopted to study the human grasp. The purpose of this work is to propose a set of measures that allow the evaluation of different aspects of the human grasp. The most common robotic grasp quality measures have been adapted to the evaluation of the human hand and a new quality measure – the fatigue index – is proposed in order to incorporate the biomechanical aspect into the evaluation. The minimum set of indices that allows the evaluation of the different aspects of the grasp is obtained from the analysis of a human prehension experiment.

  11. Blade Vibration Measurement System for Unducted Fans

    Science.gov (United States)

    Marscher, William

    2014-01-01

    With propulsion research programs focused on new levels of efficiency and noise reduction, two avenues for advanced gas turbine technology are emerging: the geared turbofan and ultrahigh bypass ratio fan engines. Both of these candidates are being pursued as collaborative research projects between NASA and the engine manufacturers. The high bypass concept from GE Aviation is an unducted fan that features a bypass ratio of over 30 along with the accompanying benefits in fuel efficiency. This project improved the test and measurement capabilities of the unducted fan blade dynamic response. In the course of this project, Mechanical Solutions, Inc. (MSI) collaborated with GE Aviation to (1) define the requirements for fan blade measurements; (2) leverage MSI's radar-based system for compressor and turbine blade monitoring; and (3) develop, validate, and deliver a noncontacting blade vibration measurement system for unducted fans.

  12. Improvement of Ultrasonic Distance Measuring System

    Directory of Open Access Journals (Sweden)

    Jiang Yu

    2018-01-01

    Full Text Available This paper mainly introduces a kind of ultrasonic distance measuring system with AT89C51 single chip as the core component. The paper expounds the principle of ultrasonic sensor and ultrasonic ranging, hardware circuit and software program, and the results of experiment and analysis.The hardware circuit based on SCM, the software design adopts the advanced microcontroller programming language.The amplitude of the received signal and the time of ultrasonic propagation are regulated by closed loop control. [1,2]The double closed loop control technology for amplitude and time improves the measuring accuracy of the instrument. The experimental results show that greatly improves the measurement accuracy of the system.

  13. Multi-scale biomedical systems: measurement challenges

    International Nuclear Information System (INIS)

    Summers, R

    2016-01-01

    Multi-scale biomedical systems are those that represent interactions in materials, sensors, and systems from a holistic perspective. It is possible to view such multi-scale activity using measurement of spatial scale or time scale, though in this paper only the former is considered. The biomedical application paradigm comprises interactions that range from quantum biological phenomena at scales of 10-12 for one individual to epidemiological studies of disease spread in populations that in a pandemic lead to measurement at a scale of 10+7. It is clear that there are measurement challenges at either end of this spatial scale, but those challenges that relate to the use of new technologies that deal with big data and health service delivery at the point of care are also considered. The measurement challenges lead to the use, in many cases, of model-based measurement and the adoption of virtual engineering. It is these measurement challenges that will be uncovered in this paper. (paper)

  14. New evaluation system for antisabotage physical protection

    International Nuclear Information System (INIS)

    Itakura, Shuichiro; Nakagome, Yoshihiro

    2008-01-01

    The discussion on an appropriate level of physical protection has not been elaborated so far because of the confidentiality of its nature, thus resulting in a lack of consensus on this issue. In view of this context, a new system for the evaluation of antisabotage physical protection systems is proposed in this paper, in which we introduce openness to a certain extent in the process of the evaluation. The proposed system is composed of the following three elements; (1) establishment of an evaluation basis threat (EBT), which should be less strong but more likely to occur than the design basis threat (DBT); (2) employment of realistic standard scenarios in the process of evaluation; (3) disclosure of results of evaluation implemented based on the above EBT and standard scenarios. It is expected that this considerably open system will foment peace of mind among citizens as well as create a deterrent effect that would minimize the occurrence of sabotage on nuclear facilities. (author)

  15. System for measuring radioactivity of labelled biopolymers

    International Nuclear Information System (INIS)

    Gross, V.

    1980-01-01

    A system is described for measuring radioactivity of labelled biopolymers, comprising: a set of containers adapted for receiving aqueous solutions of biological samples containing biopolymers which are subsequently precipitated in said containers on particles of diatomite in the presence of a coprecipitator, then filtered, dissolved, and mixed with a scintillator; radioactivity measuring means including a detection chamber to which is fed the mixture produced in said set of containers; an electric drive for moving said set of containers in a stepwise manner; means for proportional feeding of said coprecipitator and a suspension of diatomite in an acid solution to said containers which contain the biological sample for forming an acid precipitation of biopolymers; means for the removal of precipitated samples from said containers; precipitated biopolymer filtering means for successively filtering the precipitate, suspending the precipitate, dissolving the biopolymers mixed with said scintillator for feeding of the mixture to said detection chamber; a system of pipelines interconnecting said above-recited means; and said means for measuring radioactivity of labelled biopolymers including, a measuring cell arranged in a detection chamber and communicating with said means for filtering precipitated biopolymers through one pipeline of said system of pipelines; a program unit electrically connected to said electric drive, said means for acid precipatation of biopolymers, said means for the removal of precipitated samples from said containers, said filtering means, and said radioactivity measuring device; said program unit adapted to periodically switch on and off the above-recited means and check the sequence of the radioactivity measuring operations; and a control unit for controlling the initiation of the system and for selecting programs

  16. Automated System of Area Radiation Measurement (ASARM)

    International Nuclear Information System (INIS)

    Hernandez G, J.

    2013-10-01

    The realized activities in nuclear facilities involve the determination of the presence of ionizing radiation fields in the workspaces. The instruments designed to detect and to measure these radiation fields provide useful information (specific type of radiation, intensity, etc.) to take the appropriate radiological protection measures, with the purpose of reducing to the minimum the workers exposition and the people in general. The radiological protection program of Reactor TRIGA Mark III contains the instructions and procedures to implement a periodic radiological monitoring, surveillance, rising of contamination levels, type and number of the instruments required for the radiological monitoring of areas and personal. The ana logical monitoring system model Rms II used to detect and measuring exposition speed and neutron radiation fields in several areas of the installation, provides the information in a logarithmic scale measurer of 4 or 5 decades located in a shelf where the previously mentioned measurement channels are centralized. Also inside the reactor monitoring system are two monitors of radioactive material concentration in the air: The particles continuous monitor and the gaseous effluents monitor which present the referred information of the diverse detectors through ana logical readers. These monitors when operating with an ana logical indication does not present the possibility to generate historical files electronically of each monitor previously mentioned neither to generate visual and audible indications of the alarms. This work presents the Automated System of Area Radiation Measurement which potentiated the functionality of the area monitors for gamma and neutron radiation, as well as of the particles continuous monitor and the gaseous effluents of reactor TRIGA Mark III, when being developed a computer system that captures in real time the information of all the monitors, generating this way an electronic binnacle, a visual and audible alarm

  17. Fully automated system for pulsed NMR measurements

    International Nuclear Information System (INIS)

    Cantor, D.M.

    1977-01-01

    A system is described which places many of the complex, tedious operations for pulsed NMR experiments under computer control. It automatically optimizes the experiment parameters of pulse length and phase, and precision, accuracy, and measurement speed are improved. The hardware interface between the computer and the NMR instrument is described. Design features, justification of the choices made between alternative design strategies, and details of the implementation of design goals are presented. Software features common to all the available experiments are discussed. Optimization of pulse lengths and phases is performed via a sequential search technique called Uniplex. Measurements of the spin-lattice and spin-spin relaxation times and of diffusion constants are automatic. Options for expansion of the system are explored along with some of the limitations of the system

  18. Measures to Evaluate the Effects of DBS on Speech Production

    Science.gov (United States)

    Weismer, Gary; Yunusova, Yana; Bunton, Kate

    2011-01-01

    The purpose of this paper is to review and evaluate measures of speech production that could be used to document effects of Deep Brain Stimulation (DBS) on speech performance, especially in persons with Parkinson disease (PD). A small set of evaluative criteria for these measures is presented first, followed by consideration of several speech physiology and speech acoustic measures that have been studied frequently and reported on in the literature on normal speech production, and speech production affected by neuromotor disorders (dysarthria). Each measure is reviewed and evaluated against the evaluative criteria. Embedded within this review and evaluation is a presentation of new data relating speech motions to speech intelligibility measures in speakers with PD, amyotrophic lateral sclerosis (ALS), and control speakers (CS). These data are used to support the conclusion that at the present time the slope of second formant transitions (F2 slope), an acoustic measure, is well suited to make inferences to speech motion and to predict speech intelligibility. The use of other measures should not be ruled out, however, and we encourage further development of evaluative criteria for speech measures designed to probe the effects of DBS or any treatment with potential effects on speech production and communication skills. PMID:24932066

  19. Evaluation of Intersection Traffic Control Measures through Simulation

    Science.gov (United States)

    Asaithambi, Gowri; Sivanandan, R.

    2015-12-01

    Modeling traffic flow is stochastic in nature due to randomness in variables such as vehicle arrivals and speeds. Due to this and due to complex vehicular interactions and their manoeuvres, it is extremely difficult to model the traffic flow through analytical methods. To study this type of complex traffic system and vehicle interactions, simulation is considered as an effective tool. Application of homogeneous traffic models to heterogeneous traffic may not be able to capture the complex manoeuvres and interactions in such flows. Hence, a microscopic simulation model for heterogeneous traffic is developed using object oriented concepts. This simulation model acts as a tool for evaluating various control measures at signalized intersections. The present study focuses on the evaluation of Right Turn Lane (RTL) and Channelised Left Turn Lane (CLTL). A sensitivity analysis was performed to evaluate RTL and CLTL by varying the approach volumes, turn proportions and turn lane lengths. RTL is found to be advantageous only up to certain approach volumes and right-turn proportions, beyond which it is counter-productive. CLTL is found to be advantageous for lower approach volumes for all turn proportions, signifying the benefits of CLTL. It is counter-productive for higher approach volume and lower turn proportions. This study pinpoints the break-even points for various scenarios. The developed simulation model can be used as an appropriate intersection lane control tool for enhancing the efficiency of flow at intersections. This model can also be employed for scenario analysis and can be valuable to field traffic engineers in implementing vehicle-type based and lane-based traffic control measures.

  20. Dose measurements in space by the Hungarian Pille TLD system

    International Nuclear Information System (INIS)

    Apathy, I.; Deme, S.; Feher, I.; Akatov, Y.A.; Reitz, G.; Arkhanguelski, V.V.

    2002-01-01

    Exposure of crew, equipment, and experiments to the ambient space radiation environment in low Earth orbit poses one of the most significant problems to long-term space habitation. Accurate dose measurement has become increasingly important during the assembly (extravehicular activity (EVA)) and operation of space stations such as on Space Station Mir. Passive integrating detector systems such as thermoluminescent dosemeters (TLDs) are commonly used for dosimetry mapping and personal dosimetry on space vehicles. The well-known advantages of passive detector systems are their independence of power supply, small dimensions, high sensitivity, good stability, wide measuring range, resistance to environmental effects, and relatively low cost. Nevertheless, they have the general disadvantage that for evaluation purposes they need a laboratory or large--in mass and power consumption--terrestrial equipment, and consequently they cannot provide time-resolved dose data during long-term space flights. KFKI Atomic Energy Research Institute (KFKI AEKI) has developed and manufactured a series of thermoluminescent dosemeter systems for measuring cosmic radiation doses in the 10 μGy to 10 Gy range, consisting of a set of bulb dosemeters and a compact, self-contained, TLD reader suitable for on-board evaluation of the dosemeters. By means of such a system, highly accurate measurements were carried out on board the Salyut-6, -7 and Mir Space Stations as well as on the Space Shuttle. A detailed description of the system is given and the comprehensive results of these measurements are summarised

  1. How to Evaluate Integrated Library Automation Systems.

    Science.gov (United States)

    Powell, James R.; Slach, June E.

    1985-01-01

    This paper describes methodology used in compiling a list of candidate integrated library automation systems at a corporate technical library. Priorities for automation, identification of candidate systems, the filtering process, information for suppliers, software and hardware considerations, on-site evaluations, and final system selection are…

  2. Measuring the Balance Control System – Review

    Directory of Open Access Journals (Sweden)

    Jitka Jančová

    2008-01-01

    Full Text Available Past studies of postural control during standing have employed wide range of procedures including the outcome measures use to quantify postural control, the duration of the sample collected, sampling frequency and methods for data processing. Due to these differences there remains little, if any, common grounds for comparisons between studies to establish a concrete understanding of the features and bouns which characterize normal healthy postural control. This article deals with terms such as reliability and repeatability of stabilometric measurements, stabilometric data quantification and analysis. To clear up those terms is suggested, by the author of this paper, very important. The stabilometric measurements remain, nevertheless, different when dealing with aging adults. Though, we notes some alterations of the aging systems, this article is not entirely dedicated to the seniors population. Measurements of COP and technical notes remain the main axis of present paper.

  3. Modern systems for environmental radioactivity measurements

    International Nuclear Information System (INIS)

    Cimpean, A.; Borodeanu, C.

    1995-01-01

    The system for environmental radioactivity measurements with automatic data transmission represents a better solution for nuclear safety assurance. The 'intelligent probe' will be of real use for surveying the environmental radioactivity. The probes work independently. They measure the dose rate and store the data in their internal memory. Many such probes can be spread all over a large area. They are able to measure dose rate from the background level up to high catastrophic levels. A central computer 'asks' periodically the probes to send their stored data. This computer stores the data from many probes over a long time. It can show in 'windows' manner the dose rate from any probe (either in a numerical or graphical way), the position on a map of every probe and the corresponding results of the measurements. In can alert, if an alarm threshold is crossed or it can print on a printer the data for any single probe. (author)

  4. Machine vision system for measuring conifer seedling morphology

    Science.gov (United States)

    Rigney, Michael P.; Kranzler, Glenn A.

    1995-01-01

    A PC-based machine vision system providing rapid measurement of bare-root tree seedling morphological features has been designed. The system uses backlighting and a 2048-pixel line- scan camera to acquire images with transverse resolutions as high as 0.05 mm for precise measurement of stem diameter. Individual seedlings are manually loaded on a conveyor belt and inspected by the vision system in less than 0.25 seconds. Designed for quality control and morphological data acquisition by nursery personnel, the system provides a user-friendly, menu-driven graphical interface. The system automatically locates the seedling root collar and measures stem diameter, shoot height, sturdiness ratio, root mass length, projected shoot and root area, shoot-root area ratio, and percent fine roots. Sample statistics are computed for each measured feature. Measurements for each seedling may be stored for later analysis. Feature measurements may be compared with multi-class quality criteria to determine sample quality or to perform multi-class sorting. Statistical summary and classification reports may be printed to facilitate the communication of quality concerns with grading personnel. Tests were conducted at a commercial forest nursery to evaluate measurement precision. Four quality control personnel measured root collar diameter, stem height, and root mass length on each of 200 conifer seedlings. The same seedlings were inspected four times by the machine vision system. Machine stem diameter measurement precision was four times greater than that of manual measurements. Machine and manual measurements had comparable precision for shoot height and root mass length.

  5. Noise evaluation of a point autofocus surface topography measuring instrument

    Science.gov (United States)

    Maculotti, Giacomo; Feng, Xiaobing; Galetto, Maurizio; Leach, Richard

    2018-06-01

    In this work, the measurement noise of a point autofocus surface topography measuring instrument is evaluated, as the first step towards establishing a route to traceability for this type of instrument. The evaluation is based on the determination of the metrological characteristics for noise as outlined in draft ISO specification standards by using a calibrated optical flat. The static noise and repeatability of the autofocus sensor are evaluated. The influence of environmental disturbances on the measured surface topography and the built-in software to compensate for such influences are also investigated. The instrument was found to have a measurement noise of approximately 2 nm or, when expressed with the measurement bandwidth, 0.4 nm for a single-point measurement.

  6. A measure of internal synergy of the collective system

    Directory of Open Access Journals (Sweden)

    Novikov V.A.

    2013-12-01

    Full Text Available Background: The authors examine the methodology of HRM personnel management based on ratings. Proposed to represent a collective system that uses a matrix of pair relations as a system of linear differential equations. The condition of auto generation of an autonomous system can be determined by the application of the Laplace transformation to the system. This condition mainly depends on the main eigenvalue of dating relationships matrix. Assuming the oscillation frequency is straightly proportional to the system's synergy rating, a special algorithm of comparative evaluation of several collective systems was suggested. Methods: The calculation of the rating of internal synergies is based on the representation of the collective system as a system of linear differential equations, the coefficients of which are obtained by questionnaire survey of all members of the team. Internal representation of the system's synergism as a stimulation of an autonomous system allows using the eigenvector of the system as a measure of internal synergies. Results: The result of this method is the rating of members of interacting collective systems in terms of their contribution to the self-organization sharing behavior.  Conclusions:  Using a matrix of pair relations allows without direct programming and only using MathCad determines the measure of internal synergy of a collective system.  

  7. Measurement System Analyses - Gauge Repeatability and Reproducibility Methods

    Science.gov (United States)

    Cepova, Lenka; Kovacikova, Andrea; Cep, Robert; Klaput, Pavel; Mizera, Ondrej

    2018-02-01

    The submitted article focuses on a detailed explanation of the average and range method (Automotive Industry Action Group, Measurement System Analysis approach) and of the honest Gauge Repeatability and Reproducibility method (Evaluating the Measurement Process approach). The measured data (thickness of plastic parts) were evaluated by both methods and their results were compared on the basis of numerical evaluation. Both methods were additionally compared and their advantages and disadvantages were discussed. One difference between both methods is the calculation of variation components. The AIAG method calculates the variation components based on standard deviation (then a sum of variation components does not give 100 %) and the honest GRR study calculates the variation components based on variance, where the sum of all variation components (part to part variation, EV & AV) gives the total variation of 100 %. Acceptance of both methods among the professional society, future use, and acceptance by manufacturing industry were also discussed. Nowadays, the AIAG is the leading method in the industry.

  8. The SPS Individual Bunch Measurement System

    CERN Document Server

    Guerrero, A; Jones, R; Savioz, J J

    2001-01-01

    The Individual Bunch Measurement System (IBMS) allows the intensity of each bunch in an LHC batch to be the measured both in the PS to SPS transfer lines and in the SPS ring itself. The method is vased on measuring the peak and valley of the analogue signal supplied by a Fast Beam Current Transformer at a frequency of 40 MHz. A 12 bit acquisition system is required to obtain a 1% resolution for the intensity range of 5X10`9 to 1.7X10`11 protons per bunch, corresponding to the pilot and ultimate LHC bunch intensities. The acquisition selection and external trigger adjustment system is driven by the 200MHz RF, which is distributed using a single-mode fibre-optic link. A local oscilloscope, controlled via a GPIB interface, allows the remote adjustment of the timing signals. The low-level software consists of a real-time task and a communication server run on a VME Power PC, which is accessed using a graphical user interface. This paper describes the system as a whole and presents some recent uses and results fro...

  9. Developing a lean measurement system to enhance process improvement

    Directory of Open Access Journals (Sweden)

    Lewis P.

    2013-01-01

    Full Text Available A key ingredient to underpin process improvement is a robust, reliable, repeatable measurement system. Process improvement activity needs to be supported by accurate and precise data because effective decision making, within process improvement activity, demands the use of “hard” data. One of the oldest and most established process improvement methods is Deming’s Plan-Do-Check-Act (PDCA cycle which is reliant on the check phase, a measurement activity where data is being gathered and evaluated. Recent expansions of the PDCA such as the Six-Sigma Define-Measure-Analyse-Improve-Control (DMAIC methodology place significant importance upon measurement. The DMAIC cycle incorporates the regimented requirement for the inclusion of measurement system analysis (MSA into the breakthrough strategy. The call for MSA within the DMAIC cycle is to provide the improvement activity with a robust measurement system that will ensure a pertinent level of data during any validation process. The Lean methodology is heavily centred on the removal of the seven Mudas (wastes from a manufacturing process: defects, overproduction, transportation, waiting, inventory, motion and processing. The application of lean, particularly within the manufacturing industry, has led to a perception that measurement is a waste within a manufacturing process because measurement processes identify defective products. The metrologists’ pursuit for measurement excellence could be construed as a hindrance by the “cost down” demands being perpetrated from the same organisation’s lean policy. So what possible benefits does enforcing the regimes of the lean and quality philosophies upon the measurement process have and how does this ultimately enhance the process improvement activity? The key fundamental to embed with any process improvement is the removal of waste. The process improvement techniques embedded within lean and quality concepts are extremely powerful practices in the

  10. Eddy Correlation Flux Measurement System (ECOR) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Cook, DR

    2011-01-31

    The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO2) (and methane at one Southern Great Plains extended facility (SGP EF) and the North Slope of Alaska Central Facility (NSA CF). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO2 concentration.

  11. Slot Antenna for Wireless Temperature Measurement Systems

    DEFF Research Database (Denmark)

    Acar, Öncel; Jakobsen, Kaj Bjarne

    2016-01-01

    This paper presents a novel clover-slot antenna for a surface-acoustic-wave sensor based wireless temperature measurement system. The slot is described by a parametric locus curve that has the shape of a clover. The antenna is operated at high temperatures, in rough environments, and has a 43......% fractional bandwidth at the 2.4 GHz ISM-band. The slot antenna has been optimized for excitation by a passive chip soldered onto it. Measurement results are compared with simulation results and show good agreements....

  12. Electric Field Quantitative Measurement System and Method

    Science.gov (United States)

    Generazio, Edward R. (Inventor)

    2016-01-01

    A method and system are provided for making a quantitative measurement of an electric field. A plurality of antennas separated from one another by known distances are arrayed in a region that extends in at least one dimension. A voltage difference between at least one selected pair of antennas is measured. Each voltage difference is divided by the known distance associated with the selected pair of antennas corresponding thereto to generate a resulting quantity. The plurality of resulting quantities defined over the region quantitatively describe an electric field therein.

  13. The New Brunswick Laboratory Safeguards Measurement Evaluation Program

    International Nuclear Information System (INIS)

    Cacic, C.G.; Trahey, N.M.; Zook, A.C.

    1987-01-01

    The New Brunswick Laboratory (NBL) has been tasked by the U.S. Department of Energy (DOE) Office of Safeguards and Security (OSS) to assess and evaluate the adequacy of measurement technology as applied to materials accounting in DOE nuclear facilities. The Safeguards Measurement Evaluation (SME) Program was developed as a means to monitor and evaluate the quality and effectiveness of accounting measurements by site, material balance area (MBA), or unit process. Phase I of the SME Program, initiated during 1985, involved evaluation of the primary accountability measurement methods at six DOE Defense Programs facilities: Savannah River Plant, Portsmouth Gaseous Diffusion Plant, Y-12 Plant, Rocky Flats Plant, Rockwell Hanford Operations, and NBL. Samples of uranyl nitrate solution, dried plutonium nitrates, and plutonium oxides were shipped to the participants for assay and isotopic abundance measurements. Resulting data are presented and evaluated as indicators of current state-of-the-practice accountability measurement methodology, deficiencies in materials accounting practices, and areas for possible assistance in upgrading measurement capabilities. Continuing expansion of the SME Program to include materials which are representative of specific accountability measurement points within the DOE complex is discussed

  14. Methods, measures and indicators for evaluating benefits of transportation research

    CSIR Research Space (South Africa)

    Du Plessis, Louw

    2016-04-01

    Full Text Available The purpose of this article is to provide updated information by identifying and discussing methods, measures and indicators for evaluating benefits appropriate for transportation-related research facilities/programmes. The information has been...

  15. Multivariate Methods Based Soft Measurement for Wine Quality Evaluation

    Directory of Open Access Journals (Sweden)

    Shen Yin

    2014-01-01

    a decision. However, since the physicochemical indexes of wine can to some extent reflect the quality of wine, the multivariate statistical methods based soft measure can help the oenologist in wine evaluation.

  16. Thermodynamics of Weakly Measured Quantum Systems.

    Science.gov (United States)

    Alonso, Jose Joaquin; Lutz, Eric; Romito, Alessandro

    2016-02-26

    We consider continuously monitored quantum systems and introduce definitions of work and heat along individual quantum trajectories that are valid for coherent superposition of energy eigenstates. We use these quantities to extend the first and second laws of stochastic thermodynamics to the quantum domain. We illustrate our results with the case of a weakly measured driven two-level system and show how to distinguish between quantum work and heat contributions. We finally employ quantum feedback control to suppress detector backaction and determine the work statistics.

  17. The flow measurement plan for the primary system of SMART

    International Nuclear Information System (INIS)

    Lee, Jun; Seo, J. K.; Park, C. T.; Yoon, J. H.; Cho, B. H.; Lee, D. J.

    2001-08-01

    It is the common features of the integrated reactor that the main components of the primary system are installed within the reactor vessel, and so there are no any flow pipes connecting the reactor coolant pumps or steam generators. Due to no any flow pipes, it is impossible to measure the differential pressure at the primary system of the integrated reactor, and it also makes impossible measure the primary coolant flow rate. SMART is also a integrated reactor type, and have a problem as same as the above case. The objective of the study is to draw up the flow measurement plan for the primary system of SMART. In this study, firstly we reviewed the flow measurement methods at the primary system for the existing commercial nuclear power reactors. As a result of the review, we selected preliminarily the 3 methods which is a good possibility of application to SMART. The 3 methods are as follows. Flow measurement method by MCP rotation speed, flow measurement method by HBM, flow measurement method by pump motor power. For the above methods, we have evaluated whether they actually can be applied to SMART, and also have set up the concrete methodology. Finally we have made a selection of the above methods as the flow measurement plan for the primary system of SMART. Peculiarly, we did not found out a precedent which the direct pump motor power-flow rate curve is used as the flow measurement method in the existing commercial nuclear power reactors. Therefore, to use this method for SMART, it is needed to bear the follow-up measures in mind. The follow-up measures is included in this report

  18. Quantitative evaluation of physical protection system in nuclear power plant

    International Nuclear Information System (INIS)

    Sun Yahua; Li Bin; Li Shiju

    2009-01-01

    Based on the prompt detection analysis, this paper introduced one analysis model of intrusion path in nuclear power plant by means of morphology analysis and developed the evaluation software for path model analysis of physical protection system. Quantitative analysis on three elements (detection, delay, and response) of physical protection system was presented with an imaginary intrusion event example in Mac Arthur nuclear center. The results indicated that the path prompt detection analysis worked effectively to find the weak point of the physical protection system in NPP, and meantime we can also get the high cost-effectiveness improved measures. It is an effective approach to evaluate the overall performance of the system. (authors)

  19. Noncontacting Optical Measurement And Inspection Systems

    Science.gov (United States)

    Asher, Jeffrey A.; Jackson, Robert L.

    1986-10-01

    Product inspection continues to play a growing role in the improvement of quality and reduction of scrap. Recent emphasis on precision measurements and in-process inspection have been a driving force for the development of noncontacting sensors. Noncontacting sensors can provide long term, unattended use due to the lack of sensor wear. Further, in applications where, sensor contact can damage or geometrically change the part to be measured or inspected, noncontacting sensors are the only technical approach available. MTI is involved in the development and sale of noncontacting sensors and custom inspection systems. This paper will review the recent advances in noncontacting sensor development. Machine vision and fiber optics sensor systems are finding a wide variety of industrial inspection applications. This paper will provide detailed examples of several state-of-the-art applications for these noncontacting sensors.

  20. Evaluation methodologies for security testing biometric systems beyond technological evaluation

    OpenAIRE

    Fernández Saavedra, María Belén

    2013-01-01

    The main objective of this PhD Thesis is the specification of formal evaluation methodologies for testing the security level achieved by biometric systems when these are working under specific contour conditions. This analysis is conducted through the calculation of the basic technical biometric system performance and its possible variations. To that end, the next two relevant contributions have been developed. The first contribution is the definition of two independent biometric performance ...

  1. Evaluation of real time operating system

    International Nuclear Information System (INIS)

    Lee, Cheol Hoon; Cho, Moon Heang; Choi, In Bum; Lee, Jung Won; Kang, Hui Sung

    2006-02-01

    An hard RTOS used in the Nuclear Power Plants must satisfy severe performance requirements even in a worst case scenario. Since operating systems are becoming more complicated, it is not an easy job to evaluate them. So it becomes more important how to evaluate the RTOS's used in the Nuclear Power Plants. The purpose of this work is to survey design examples and performance models of RTOS's used in the nuclear power plants and based on this survey, develop a evaluation technologies

  2. Modeling a support system for the evaluator

    International Nuclear Information System (INIS)

    Lozano Lima, B.; Ilizastegui Perez, F; Barnet Izquierdo, B.

    1998-01-01

    This work gives evaluators a tool they can employ to give more soundness to their review of operational limits and conditions. The system will establish the most adequate method to carry out the evaluation, as well as to evaluate the basis for technical operational specifications. It also includes the attainment of alternative questions to be supplied to the operating entity to support it in decision-making activities

  3. Performance measurement system for training simulators. Interim report

    International Nuclear Information System (INIS)

    Bockhold, G. Jr.; Roth, D.R.

    1978-05-01

    In the first project phase, the project team has designed, installed, and test run on the Browns Ferry nuclear power plant training simulator a performance measurement system capable of automatic recording of statistical information on operator actions and plant response. Key plant variables and operator actions were monitored and analyzed by the simulator computer for a selected set of four operating and casualty drills. The project has the following objectives: (1) To provide an empirical data base for statistical analysis of operator reliability and for allocation of safety and control functions between operators and automated controls; (2) To develop a method for evaluation of the effectiveness of control room designs and operating procedures; and (3) To develop a system for scoring aspects of operator performance to assist in training evaluations and to support operator selection research. The performance measurement system has shown potential for meeting the research objectives. However, the cost of training simulator time is high; to keep research program costs reasonable, the measurement system is being designed to be an integral part of operator training programs. In the pilot implementation, participating instructors judged the measurement system to be a valuable and objective extension of their abilities to monitor trainee performance

  4. Evaluation system of minerals reserve at Nuclebras

    International Nuclear Information System (INIS)

    Marques, J.P.M.; Guerra, P.A.G.; Vinha, C.A.G. da.

    1980-01-01

    The paper describes the methodology used for the reserve evaluation of minerals, particularly of uranium, as used world wide, and specially at Nuclebras. The paper discusses a series of procedures envolving basic definitions, reserve evaluation methods (Conventional, Statistical and Geoestatistical), data management, use of computer systems, classification of reserves as well as the results achieved [pt

  5. Performance Evaluation of Proportional Fair Scheduling Algorithm with Measured Channels

    DEFF Research Database (Denmark)

    Sørensen, Troels Bundgaard; Pons, Manuel Rubio

    2005-01-01

    subjected to measured channel traces. Specifically, we applied measured signal fading recorded from GSM cell phone users making calls on an indoor wireless office system. Different from reference channel models, these measured channels have much more irregular fading between users, which as we show...

  6. The Efficacy of Stuttering Measurement Training: Evaluating Two Training Programs

    Science.gov (United States)

    Bainbridge, Lauren A.; Stavros, Candace; Ebrahimian, Mineh; Wang, Yuedong; Ingham, Roger J.

    2015-01-01

    Purpose: Two stuttering measurement training programs currently used for training clinicians were evaluated for their efficacy in improving the accuracy of total stuttering event counting. Method: Four groups, each with 12 randomly allocated participants, completed a pretest-posttest design training study. They were evaluated by their counts of…

  7. Designing an accurate system for temperature measurements

    Directory of Open Access Journals (Sweden)

    Kochan Orest

    2017-01-01

    Full Text Available The method of compensation of changes in temperature field along the legs of inhomogeneous thermocouple, which measures a temperature of an object, is considered in this paper. This compensation is achieved by stabilization of the temperature field along the thermocouple. Such stabilization does not allow the error due to acquired thermoelectric inhomogeneity to manifest itself. There is also proposed the design of the furnace to stabilize temperature field along the legs of the thermocouple which measures the temperature of an object. This furnace is not integrated with the thermocouple mentioned above, therefore it is possible to replace this thermocouple with a new one when it get its legs considerably inhomogeneous.. There is designed the two loop measuring system with the ability of error correction which can use simultaneously a usual thermocouple as well as a thermocouple with controlled profile of temperature field. The latter can be used as a reference sensor for the former.

  8. Measuring Principals' Effectiveness: Results from New Jersey's First Year of Statewide Principal Evaluation. REL 2016-156

    Science.gov (United States)

    Herrmann, Mariesa; Ross, Christine

    2016-01-01

    States and districts across the country are implementing new principal evaluation systems that include measures of the quality of principals' school leadership practices and measures of student achievement growth. Because these evaluation systems will be used for high-stakes decisions, it is important that the component measures of the evaluation…

  9. Nuclear instrumentation for the industrial measuring systems

    International Nuclear Information System (INIS)

    Normand, S.

    2010-01-01

    This work deals with nuclear instrumentation and its application to industry, power plant fuel reprocessing plant and finally with homeland security. The first part concerns the reactor instrumentation, in-core and ex-core measurement system. Ionization Uranium fission chamber will be introduced with their acquisition system especially Campbell mode system. Some progress have been done on regarding sensors failure foresee. The second part of this work deals with reprocessing plant and associated instrumentation for nuclear waste management. Proportional counters techniques will be discussed, especially Helium-3 counter, and new development on electronic concept for reprocessing nuclear waste plant (one electronic for multipurpose acquisition system). For nuclear safety and security for human and homeland will be introduce. First we will explain a new particular approach on operational dosimetric measurement and secondly, we will show new kind of organic scintillator material and associated electronics. Signal treatment with real time treatment is embedded, in order to make neutron gamma discrimination possible even in solid organic scintillator. Finally, the conclusion will point out future, with most trends in research and development on nuclear instrumentation for next years. (author) [fr

  10. Waste assay measurement integration system user interface

    International Nuclear Information System (INIS)

    Mousseau, K.C.; Hempstead, A.R.; Becker, G.K.

    1995-01-01

    The Waste Assay Measurement Integration System (WAMIS) is being developed to improve confidence in and lower the uncertainty of waste characterization data. There are two major components to the WAMIS: a data access and visualization component and a data interpretation component. The intent of the access and visualization software is to provide simultaneous access to all data sources that describe the contents of any particular container of waste. The visualization software also allows the user to display data at any level from raw to reduced output. Depending on user type, the software displays a menuing hierarchy, related to level of access, that allows the user to observe only those data sources s/he has been authorized to view. Access levels include system administrator, physicist, QA representative, shift operations supervisor, and data entry. Data sources are displayed in separate windows and presently include (1) real-time radiography video, (2) gamma spectra, (3) passive and active neutron, (4) radionuclide mass estimates, (5) total alpha activity (Ci), (6) container attributes, (7) thermal power (w), and (8) mass ratio estimates for americium, plutonium, and uranium isotopes. The data interpretation component is in the early phases of design, but will include artificial intelligence, expert system, and neural network techniques. The system is being developed on a Pentium PC using Microsoft Visual C++. Future generations of WAMIS will be UNIX based and will incorporate more generically radiographic/tomographic, gamma spectroscopic/tomographics, neutron, and prompt gamma measurements

  11. Good Evaluation Measures: More than Their Psychometric Properties

    Science.gov (United States)

    Weitzman, Beth C.; Silver, Diana

    2013-01-01

    In this commentary, we examine Braverman's insights into the trade-offs between feasibility and rigor in evaluation measures and reject his assessment of the trade-off as a zero-sum game. We, argue that feasibility and policy salience are, like reliability and validity, intrinsic to the definition of a good measure. To reduce the tension between…

  12. Young Children's Understandings of Length Measurement: Evaluating a Learning Trajectory

    Science.gov (United States)

    Szilagyi, Janka; Clements, Douglas H.; Sarama, Julie

    2013-01-01

    This study investigated the development of length measurement ideas in students from prekindergarten through 2nd grade. The main purpose was to evaluate and elaborate the developmental progression, or levels of thinking, of a hypothesized learning trajectory for length measurement to ensure that the sequence of levels of thinking is consistent…

  13. Design and evaluation of an integrated safeguards system: principles

    International Nuclear Information System (INIS)

    Markin, J.T.; Coulter, C.A.; Gutmacher, R.G.; Whitty, W.J.

    1984-07-01

    An integrated safeguards system is defined as a collection of safeguards activities in which system components are coordinated to meet safeguards objectives efficiently within constraints imposed by safeguards resources, facility operations, potential adversaries, and regulatory requirements. This paper describes principles for designing and evaluating an integrated safeguards system that consists of four parts: (1) a problem definition phase that specifies resources and constraints composing the problem boundary values; (2) a system analysis/synthesis phase that describes how to select and integrate safeguards activities for efficient attainment of system objectives; (3) a system evaluation/optimization phase that defines measures of safeguards performance and develops methods for evaluating them; and (4) a decision-making phase that develops principles for selecting admissible designs and preference-ordering designs. 6 references, 4 figures, 5 tables

  14. Design and evaluation of an integrated safeguards system: principles

    International Nuclear Information System (INIS)

    Markin, J.T.; Coulter, C.A.; Gutmacher, R.G.; Whitty, W.J.

    1984-01-01

    An integrated safeguards system is defined as a collection of safeguards activities in which system components are coordinated to meet safeguards objectives efficiently within constraints imposed by safeguards resources, facility operations, potential adversaries, and regulatory requirements. This paper describes principles for designing and evaluating an integrated safeguards system that consists of four parts: a problem definition phase that specifies resources and constraints composing the problem boundary values, a system analysis/synthesis phase that describes how to select and integrate safeguards activities for efficient attainment of system objectives, a system evaluation/optimization phase that defines measures of safeguards performance and develops methods for evaluating them, and a decision-making phase that develops principles for selecting admissible designs and preference-ordering designs

  15. Measurement system for ultrahigh temperature thermophysical properties

    International Nuclear Information System (INIS)

    Fukuyama, Hiroyuki

    2015-01-01

    Properties and Simulations Probed with Electromagnetic Containerless Technique (PROSPECT) is a measurement system for ultrahigh temperature thermophysical properties to be able to measure thermophysical properties with high precision by combining AC magnetic field (electromagnetic levitation device) and DC magnetic field (superconducting magnet) to realize the static floating state of metallic melt, in other words, the state of suppressing the surface vibration of droplets, translational motion, and internal convection. The electromagnetic levitation method is a method to obtain a floating force due to the Lorentz force generated by the interaction between high-frequency current flowing in the coil and the induced current generated in a sample, and to heat/melt the sample with the Joule heat generated by its induced current. This paper roughly explains the element technologies of PROSPECT with a focus on the laser modulation calorimetry (laser periodic heating method), normal spectral emissivity measurement method, density measurement, and surface tension measurement method. Furthermore, as the application of PROSPECT to new research deployment, it introduces the observation of phase separation structure in the supercooled solidification structure of Cu-Co alloy. (A.O.)

  16. PERFORMANCE EVALUATION OF THERMOGRAPHIC CAMERAS FOR PHOTOGRAMMETRIC MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    N. Yastikli

    2013-05-01

    Full Text Available The aim of this research is the performance evaluation of the termographic cameras for possible use for photogrammetric documentation and deformation analyses caused by moisture and isolation problem of the historical and cultural heritage. To perform geometric calibration of the termographic camera, the 3D test object was designed with 77 control points which were distributed in different depths. For performance evaluation, Flir A320 termographic camera with 320 × 240 pixels and lens with 18 mm focal length was used. The Nikon D3X SLR digital camera with 6048 × 4032 pixels and lens with 20 mm focal length was used as reference for comparison. The size of pixel was 25 μm for the Flir A320 termographic camera and 6 μm for the Nikon D3X SLR digital camera. The digital images of the 3D test object were recorded with the Flir A320 termographic camera and Nikon D3X SLR digital camera and the image coordinate of the control points in the images were measured. The geometric calibration parameters, including the focal length, position of principal points, radial and tangential distortions were determined with introduced additional parameters in bundle block adjustments. The measurement of image coordinates and bundle block adjustments with additional parameters were performed using the PHIDIAS digital photogrammetric system. The bundle block adjustment was repeated with determined calibration parameter for both Flir A320 termographic camera and Nikon D3X SLR digital camera. The obtained standard deviation of measured image coordinates was 9.6 μm and 10.5 μm for Flir A320 termographic camera and 8.3 μm and 7.7 μm for Nikon D3X SLR digital camera. The obtained standard deviation of measured image points in Flir A320 termographic camera images almost same accuracy level with digital camera in comparison with 4 times bigger pixel size. The obtained results from this research, the interior geometry of the termographic cameras and lens distortion was

  17. Performance Evaluation of Thermographic Cameras for Photogrammetric Measurements

    Science.gov (United States)

    Yastikli, N.; Guler, E.

    2013-05-01

    The aim of this research is the performance evaluation of the termographic cameras for possible use for photogrammetric documentation and deformation analyses caused by moisture and isolation problem of the historical and cultural heritage. To perform geometric calibration of the termographic camera, the 3D test object was designed with 77 control points which were distributed in different depths. For performance evaluation, Flir A320 termographic camera with 320 × 240 pixels and lens with 18 mm focal length was used. The Nikon D3X SLR digital camera with 6048 × 4032 pixels and lens with 20 mm focal length was used as reference for comparison. The size of pixel was 25 μm for the Flir A320 termographic camera and 6 μm for the Nikon D3X SLR digital camera. The digital images of the 3D test object were recorded with the Flir A320 termographic camera and Nikon D3X SLR digital camera and the image coordinate of the control points in the images were measured. The geometric calibration parameters, including the focal length, position of principal points, radial and tangential distortions were determined with introduced additional parameters in bundle block adjustments. The measurement of image coordinates and bundle block adjustments with additional parameters were performed using the PHIDIAS digital photogrammetric system. The bundle block adjustment was repeated with determined calibration parameter for both Flir A320 termographic camera and Nikon D3X SLR digital camera. The obtained standard deviation of measured image coordinates was 9.6 μm and 10.5 μm for Flir A320 termographic camera and 8.3 μm and 7.7 μm for Nikon D3X SLR digital camera. The obtained standard deviation of measured image points in Flir A320 termographic camera images almost same accuracy level with digital camera in comparison with 4 times bigger pixel size. The obtained results from this research, the interior geometry of the termographic cameras and lens distortion was modelled efficiently

  18. A gaseous measurement system for carbon-14 dioxide and carbon-14 methane: An analytical methodology to be applied in the evaluation of the carbon-14 dioxide and carbon-14 methane produced via microbial activity in volcanic tuff

    International Nuclear Information System (INIS)

    Dolan, M.M.

    1987-01-01

    The objectives of this study were to develop a gaseous measurement system for the carbon-14 dioxide and carbon-14 methane produced via microbial activity or geochemical action on leachate in tuff; to determine the trapping efficiency of the system for carbon-14 dioxide; to determine the trapping efficiency of the system for carbon-14 methane; to apply the experimentally determined factors regarding the system's trapping efficiency for carbon-14 dioxide and carbon-14 methane to a trapping algorithm to determine the activity of the carbon-14 dioxide and carbon-14 methane in a mixed sample; to determine the minimum detectable activity of the measurement process in picocuries per liter; and to determine the lower limit or detection of the measurement process in counts per minute

  19. Corrective measures evaluation report for technical area-v groundwater.

    Energy Technology Data Exchange (ETDEWEB)

    Witt, Johnathan L (North Wind, Inc., Idaho Falls, ID); Orr, Brennon R. (North Wind, Inc., Idaho Falls, ID); Dettmers, Dana L. (North Wind, Inc., Idaho Falls, ID); Hall, Kevin A. (North Wind, Inc., Idaho Falls, ID); Howard, Hope (North Wind, Inc., Idaho Falls, ID)

    2005-07-01

    This Corrective Measures Evaluation Report was prepared as directed by the Compliance Order on Consent issued by the New Mexico Environment Department to document the process of selecting the preferred remedial alternative for contaminated groundwater at Technical Area V. Supporting information includes background information about the site conditions and potential receptors and an overview of work performed during the Corrective Measures Evaluation. Evaluation of remedial alternatives included identification and description of four remedial alternatives, an overview of the evaluation criteria and approach, qualitative and quantitative evaluation of remedial alternatives, and selection of the preferred remedial alternative. As a result of the Corrective Measures Evaluation, it was determined that monitored natural attenuation of all contaminants of concern (trichloroethene, tetrachloroethene, and nitrate) was the preferred remedial alternative for implementation as the corrective measure to remediate contaminated groundwater at Technical Area V of Sandia National Laboratories/New Mexico. Finally, design criteria to meet cleanup goals and objectives and the corrective measures implementation schedule for the preferred remedial alternative are presented.

  20. Automatic system for evaluation of ionizing field

    International Nuclear Information System (INIS)

    Pimenta, N.L.; Calil, S.J.

    1992-01-01

    A three-dimensional cartesian manipulator for evaluating the ionizing field and able to position a ionization chamber in any point of the space is developed. The control system is made using a IBM microcomputer. The system aimed the study of isodose curves from ionizing sources, verifying the performance of radiotherapeutic equipment. (C.G.C.)

  1. Expected energy production evaluation for photovoltaic systems

    DEFF Research Database (Denmark)

    Ding, Yi; Østergaard, Jacob; Peng, Wang

    2011-01-01

    A photovoltaic (PV) system consists of many solar panels, which are connected in series, parallel or a combination of both. Energy production for the PV system with various configurations is different. In this paper, a methodology is developed to evaluate and analyze the expected energy production...

  2. Dosimetry with alanine/electron spin resonance. Measuring and evaluating

    International Nuclear Information System (INIS)

    Anton, M.

    2007-02-01

    In the first part of the present report a short outline of the theoretical foundations in view of the parameters and evaluation programs described in the following is given. The second part described the measurement procedures and the handling of the measuring data including the applied data formats. In the third part the collection SPAD of MATLAB programs is described, which are necessary for the processing of the measurment data and the subsequent evaluations. Routine evaluations can by means of the present graphic user surface simply be performed. But the described routines can (and shall) be used also as kit in order to solve special evaluation problems. The third part closes with a listing of all programs including the online available aid texts. All functions were tested both under MATLAB 6 and under MATLAB 7

  3. Multidimensional evaluation on FR cycle systems

    International Nuclear Information System (INIS)

    Nakai, Ryodai; Fujii, Sumio; Takakuma, Katsuyuki; Katoh, Atsushi; Ono, Kiyoshi; Ohtaki, Akira; Shiotani, Hiroki

    2004-01-01

    This report explains some results of the multidimensional evaluation on various fast reactor cycle system concepts from an interim report of the 2nd phase of ''Feasibility Study on Commercialized FR Cycle System''. This method is designed to give more objective and more quantitative evaluations to clarify commercialized system candidate concepts. Here we brief current evaluation method from the five viewpoints of safety, economy, environment, resource and non-proliferation, with some trial evaluation results for some cycles consist of promising technologies in reactor, core and fuel, reprocessing and fuel manufacture. Moreover, we describe FR cycle deployment scenarios which describe advantages and disadvantages of the cycles from the viewpoints of uranium resource and radioactive waste based on long-term nuclear material mass flow analyses and advantages of the deployment of FR cycle itself from the viewpoints of the comparison with alternative power supplies as well as cost and benefit. (author)

  4. Evaluation of pipeline leak detection systems

    International Nuclear Information System (INIS)

    Glauz, W.D.; Flora, J.D.; Hennon, G.J.

    1993-01-01

    Leaking underground storage tank system presents an environmental concern and a potential health hazard. It is well known that leaks in the piping associated with these systems account for a sizeable fraction of the leaks. EPA has established performance standards for pipeline leak detection systems, and published a document presenting test protocols for evaluating these systems against the standards. This paper discusses a number of facets and important features of evaluating such systems, and presents results from tests of several systems. The importance of temperature differences between the ground and the product in the line is shown both in theory and with test data. The impact of the amount of soil moisture present is addressed, along with the effect of frozen soil. These features are addressed both for line tightness test systems, which must detect leaks of 0.10 gal/h (0.38 L/h) at 150% of normal line pressure, or 0.20 gal/h (0.76 L/h) at normal line pressure, and for automatic line leak detectors that must detect leaks of 3 gal/h (11 L/h) at 10 psi (69 kPa) within an hour of the occurrence of the leak. This paper also addresses some statistical aspects of the evaluation of these systems. Reasons for keeping the evaluation process ''blind'' to the evaluated company are given, along with methods for assuring that the tests are blind. Most importantly, a test procedure is presented for evaluating systems that report a flow rate (not just a pass/fail decision) that is much more efficient than the procedure presented in the EPA protocol, and is just as stringent

  5. Error Ellipsoid Analysis for the Diameter Measurement of Cylindroid Components Using a Laser Radar Measurement System

    Directory of Open Access Journals (Sweden)

    Zhengchun Du

    2016-05-01

    Full Text Available The use of three-dimensional (3D data in the industrial measurement field is becoming increasingly popular because of the rapid development of laser scanning techniques based on the time-of-flight principle. However, the accuracy and uncertainty of these types of measurement methods are seldom investigated. In this study, a mathematical uncertainty evaluation model for the diameter measurement of standard cylindroid components has been proposed and applied to a 3D laser radar measurement system (LRMS. First, a single-point error ellipsoid analysis for the LRMS was established. An error ellipsoid model and algorithm for diameter measurement of cylindroid components was then proposed based on the single-point error ellipsoid. Finally, four experiments were conducted using the LRMS to measure the diameter of a standard cylinder in the laboratory. The experimental results of the uncertainty evaluation consistently matched well with the predictions. The proposed uncertainty evaluation model for cylindrical diameters can provide a reliable method for actual measurements and support further accuracy improvement of the LRMS.

  6. Measuring Health Literacy in Individuals with Diabetes: A Systematic Review and Evaluation of Available Measures

    Science.gov (United States)

    Al Sayah, Fatima; Williams, Beverly; Johnson, Jeffrey A.

    2013-01-01

    Objective: To identify instruments used to measure health literacy and numeracy in people with diabetes; evaluate their use, measurement scope, and properties; discuss their strengths and weaknesses; and propose the most useful, reliable, and applicable measure for use in research and practice settings. Methods" A systematic literature review…

  7. Leak rate measurements and detection systems

    International Nuclear Information System (INIS)

    Kupperman, D.; Shack, W.J.; Claytor, T.

    1983-10-01

    A research program is under way to evaluate and develop improve leak detection systems. The primary focus of the work has been on acoustic emission detection of leaks. Leaks from artificial flaws, laboratory-generated IGSCCs and thermal fatigue cracks, and field-induced intergranular stress corrosion cracks (IGSCCs) from reactor piping have been examined. The effects of pressure, temperature, and leak rate and geometry on the acoustic signature are under study. The use of cross-correlation techniques for leak location and pattern recognition and autocorrelation for source discrimination is also being considered

  8. A review of definitions and measures of system resilience

    International Nuclear Information System (INIS)

    Hosseini, Seyedmohsen; Barker, Kash; Ramirez-Marquez, Jose E.

    2016-01-01

    Modeling and evaluating the resilience of systems, potentially complex and large-scale in nature, has recently raised significant interest among both practitioners and researchers. This recent interest has resulted in several definitions of the concept of resilience and several approaches to measuring this concept, across several application domains. As such, this paper presents a review of recent research articles related to defining and quantifying resilience in various disciplines, with a focus on engineering systems. We provide a classification scheme to the approaches in the literature, focusing on qualitative and quantitative approaches and their subcategories. Addressed in this review are: an extensive coverage of the literature, an exploration of current gaps and challenges, and several directions for future research. - Highlights: • A comprehensive review of definitions and measures of system resilience. • Focus given to resilience in engineering systems is provided. • Nearly 150 articles across several domains are reviewed. • Future directions in resilience research are discussed.

  9. Accuracy evaluation of pendulum gravity measurements of Robert von Sterneck

    Directory of Open Access Journals (Sweden)

    Alena Pešková

    2015-06-01

    Full Text Available The accuracy of first pendulum gravity measurements in the Czech territory was determined using both original surveying notebooks of Robert Daublebsky von Sterneck and modern technologies. Since more accurate methods are used for gravity measurements nowadays, our work is mostly important from the historical point of view. In previous  works, the accuracy of Sterneck’s gravity measurements was determined using only a small dataset. Here we process all Sterneck’s measurements from the Czech territory (a dataset ten times larger than in the previous works, and we complexly assess the accuracy of these measurements. Locations of the measurements were found with the help of original notebooks. Gravity in the site was interpolated using actual gravity models. Finally, the accuracy of Sterneck’s measurements was evaluated as the difference between the measured and interpolated gravity.

  10. Evaluating Management Information Systems, A Protocol for Automated Peer Review Systems

    Science.gov (United States)

    Black, Gordon C.

    1980-01-01

    This paper discusses key issues in evaluating an automated Peer Review System. Included are the conceptual base, design, steps in planning structural components, operation parameters, criteria, costs and a detailed outline or protocol for use in the evaluation. At the heart of the Peer Review System is the criteria utilized for measuring quality. Criteria evaluation should embrace, as a minimum, appropriateness, validity and reliability, and completemess or comprehensiveness of content. Such an evaluation is not complete without determining the impact (clinical outcome) of the service system or the patient and the population served.

  11. Ensuring system security through formal software evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Howell, J A; Fuyat, C [Los Alamos National Lab., NM (United States); Elvy, M [Marble Associates, Boston, MA (United States)

    1992-01-01

    With the increasing use of computer systems and networks to process safeguards information in nuclear facilities, the issue of system and data integrity is receiving worldwide attention. Among the many considerations are validation that the software performs as intended and that the information is adequately protected. Such validations are often requested of the Safeguards Systems Group of the Los Alamos National Laboratory. This paper describes our methodology for performing these software evaluations.

  12. Exploration of nuclear power enterprise 'STAR' management performance evaluation system

    International Nuclear Information System (INIS)

    Wang Sen

    2005-01-01

    From the angle of nuclear power enterprise safety culture, this essay breaks the connotations of the safety culture down to nine aspects (target management, safety management, quality management, housekeeping, cost control, authorization management, teamwork, communication and continued improvement), with each aspect divided into five levels of star class according to its own characteristics. A comparison is made between the actualities of the enterprise and star management performance evaluation system to find out the gap and identify ways of continued improvement to elevate the enterprise management level, thereby developing a standard system of conducting qualitative and quantitative evaluation to the management process. Apart from its evaluation function, this system provides a guideline on the work orientation, method, and steps to elevate work level and capability for the managers performing specific management actions. It is also a system of measuring and evaluating the executive force of the company's management and its employees. (author)

  13. EAST machine assembly and its measurement system

    International Nuclear Information System (INIS)

    Wu, S.T.

    2005-01-01

    The EAST (HT-7U) superconducting tokamak consists of a superconducting poloidal field magnet system, a toroidal field magnet system, a vacuum vessel and in-vessel components, thermal shields and a cryostat vessel. The main parts of the machine have been delivered to ASIPP (Institute of Plasma Physics, Chinese Academy of Sciences) successionally from 2003. For its complicated constitution and precise requirement, a reasonable assembly procedure and measurement technique should be defined carefully. Before the assembly procedure, a reference frame has been set up with reference fiducial targets on the wall of the test hall by an industrial measurement system. After the torus of TF coils is formed, a new reference frame will be set up from the position of the TF torus. The vacuum vessel with all inner parts will be installed with reference of the new reference frame. The big size and mass of components, special configuration of the superconducting machine with tight installation tolerances of the HT-7U (EAST) machine result in complicated assembly procedure. The procedure had begun with the installation of the support frame and the base of cryostat vessel last year. In this paper, the requirements of the assembly precise for some key components of the machine are described. The reference frame for the assembly and maintenance is explained. The assembly procedure is introduced

  14. Automatic radiation measuring system connected with GPS

    International Nuclear Information System (INIS)

    Tanigaki, Minoru

    2014-01-01

    The most serious nuclear disaster in Japan has broken out at Fukushima Daiichi Nuclear Power Plant due to Great East Japan Earthquake. Prompt and exact mapping of the contamination is of great importance for radiation protection and for the environment restoration. We have developed radiation survey systems KURAMA and KURAMA-2 for rapid and exact measurement of radiation dose distribution. The system is composed of a mobile radiation monitor and the computer in office which is for the storage and visualization of the data. They are connected with internet and are operated for continuous radiation measurement while the monitor is moving. The mobile part consists of a survey meter, an interface to transform the output of the survey meter for the computer, a global positioning system, a computer to process the data for connecting to the network, and a mobile router. Thus they are effective for rapid mapping of the surface contamination. The operation and the performance of the equipment at the site are presented. (J.P.N.)

  15. System Modeling and Trust Evaluation of Distributed Systems

    OpenAIRE

    Alhadad , Nagham; Serrano-Alvarado , Patricia; Busnel , Yann; Lamarre , Philippe

    2015-01-01

    International audience; Nowadays, digital systems are connected through complex architectures. These systems involve persons, physical and digital resources such that we can consider that a system consists of elements from two worlds, the social world and the digital world, and their relations. Users perform activities like chatting, buying, sharing data, etc. Evaluating and choosing appropriate systems involve aspects like functionality, performance, QoS, ease of use, or price. Recently, tru...

  16. System to Measure Thermal Conductivity and Seebeck Coefficient for Thermoelectrics

    Science.gov (United States)

    Kim, Hyun-Jung; Skuza, Jonathan R.; Park, Yeonjoon; King, Glen C.; Choi, Sang H.; Nagavalli, Anita

    2012-01-01

    The Seebeck coefficient, when combined with thermal and electrical conductivity, is an essential property measurement for evaluating the potential performance of novel thermoelectric materials. However, there is some question as to which measurement technique(s) provides the most accurate determination of the Seebeck coefficient at elevated temperatures. This has led to the implementation of nonstandardized practices that have further complicated the confirmation of reported high ZT materials. The major objective of the procedure described is for the simultaneous measurement of the Seebeck coefficient and thermal diffusivity within a given temperature range. These thermoelectric measurements must be precise, accurate, and reproducible to ensure meaningful interlaboratory comparison of data. The custom-built thermal characterization system described in this NASA-TM is specifically designed to measure the inplane thermal diffusivity, and the Seebeck coefficient for materials in the ranging from 73 K through 373 K.

  17. Automatic actinometric system for diffuse radiation measurement

    Science.gov (United States)

    Litwiniuk, Agnieszka; Zajkowski, Maciej

    2015-09-01

    Actinometric station is using for measuring solar of radiation. The results are helpful in determining the optimal position of solar panels relative to the Sun, especially in today's world, when the energy coming from the Sun and other alternative sources of energy become more and more popular. Polish climate does not provide as much energy as in countries in southern Europe, but it is possible to increase the amount of energy produced by appropriate arrangement of photovoltaic panels. There is the possibility of forecasting the amount of produced energy, the cost-effectiveness and profitability of photovoltaic installations. This implies considerable development opportunities for domestic photovoltaic power plants. This article presents description of actinometric system for diffuse radiation measurement, which is equipped with pyranometer - thermopile temperature sensor, amplifier AD620, AD Converter ADS1110, microcontroller Atmega 16, SD card, GPS module and LCD screen.

  18. Physical protection system design and evaluation

    International Nuclear Information System (INIS)

    Williams, J.D.

    1997-01-01

    The design of an effective physical protection system includes the determination of physical protection system objectives, initial design of a physical protection system, design evaluation, and probably a redesign or refinement. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary's capabilities, and range of adversary's tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the physical protection system, that is, open-quotes what to protect against whom.close quotes The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control elements, procedures, communication devices, and protective forces personnel to meet the objectives of the system. Once a physical protection system is designed, it must be analyzed and evaluated to ensure it meets the physical protection objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. This paper reviews the physical protection system design and methodology mentioned above. Examples of the steps required and a brief introduction to some of the technologies used in modem physical protections system are given

  19. Evaluation of flow hood measurements for residential register flows; TOPICAL

    International Nuclear Information System (INIS)

    Walker, I.S.; Wray, C.P.; Dickerhoff, D.J.; Sherman, M.H.

    2001-01-01

    Flow measurement at residential registers using flow hoods is becoming more common. These measurements are used to determine if the HVAC system is providing adequate comfort, appropriate flow over heat exchangers and in estimates of system energy losses. These HVAC system performance metrics are determined by using register measurements to find out if individual rooms are getting the correct airflow, and in estimates of total air handler flow and duct air leakage. The work discussed in this paper shows that commercially available flow hoods are poor at measuring flows in residential systems. There is also evidence in this and other studies that flow hoods can have significant errors even when used on the non-residential systems they were originally developed for. The measurement uncertainties arise from poor calibrations and the sensitivity of exiting flow hoods to non-uniformity of flows entering the device. The errors are usually large-on the order of 20% of measured flow, which is unacceptably high for most applications. Active flow hoods that have flow measurement devices that are insensitive to the entering airflow pattern were found to be clearly superior to commercially available flow hoods. In addition, it is clear that current calibration procedures for flow hoods may not take into account any field application problems and a new flow hood measurement standard should be developed to address this issue

  20. Measures for Ph.D. Evaluation: The Recruitment Process

    Science.gov (United States)

    D'Agostino, Antonella; Fruzzetti, Stefania; Ghellini, Giulio; Neri, Laura

    2011-01-01

    In the last years the quality of Higher Education (HE) system and its evaluation have been key issues of the political and scientific debate on education policies all over Europe. In the wide landscape that involves the entire HE system we draw attention on the third level of its organization, i.e. the Ph.D. In particular, this paper discusses the…

  1. Transmission Quality Measurements in DAB+ Broadcast System

    Directory of Open Access Journals (Sweden)

    Gilski Przemysław

    2017-12-01

    Full Text Available In the age of digital media, delivering broadcast content to customers at an acceptable level of quality is one of the most challenging tasks. The most important factor is the efficient use of available resources, including bandwidth. An appropriate way of managing the digital multiplex is essential for both the economic and technical issues. In this paper we describe transmission quality measurements in the DAB+ broadcast system. We provide a methodology for analysing parameters and factors related with the efficiency and reliability of a digital radio link. We describe a laboratory stand that can be used for transmission quality assessment on a regional and national level.

  2. Theoretical evaluation of measurement uncertainties of two-color pyrometry applied to optical diagnostics

    International Nuclear Information System (INIS)

    Fu Tairan; Cheng Xiaofang; Yang Zangjian

    2008-01-01

    We present a theoretical analysis of two-color pyrometry applied to optical diagnostics. A two-color pyrometer built with a single CCD is advantageous due to the simple system design. We evaluate the possibility and degree of ill-conditionness on the basis of measurement uncertainties for different measurement approaches of this two-color system. We classify measurement approaches. The corresponding ill-conditionness criterion is established. The greater the criterion value is, the worse the ill-conditioned degree of solution is. So, the optimum choice of measurement approach for the two-color system is achieved through intercomparison of the criterion values. Numerical examples are also given to illustrate this point. The theoretical analysis not only provides an effective way of evaluating different measurement approaches, but also may help us to better understand the influences that determine the choices between wavelength/waveband measurements and calibration/noncalibration modes for temperature and soot distribution

  3. Evaluation of the new respiratory gating system

    Science.gov (United States)

    Shi, Chengyu; Tang, Xiaoli; Chan, Maria

    2018-01-01

    Objective The newly released Respiratory Gating for Scanners (RGSC; Varian Medical Systems, Palo Alto, CA, USA) system has limited existing quality assurance (QA) protocols and pertinent publications. Herein, we report our experiences of the RGSC system acceptance and QA. Methods The RGSC system integration was tested with peripheral equipment, spatial reproducibility, and dynamic localization accuracy for regular and irregular breathing patterns, respectively. A QUASAR Respiratory Motion Phantom and a mathematical fitting method were used for data acquisition and analysis. Results The results showed that the RGSC system could accurately measure regular motion periods of 3–10 s. For irregular breathing patterns, differences from the existing Real-time Position Management (RPM; Varian Medical Systems, Palo Alto, CA) system were observed. For dynamic localization measurements, the RGSC system showed 76% agreement with the programmed test data within ±5% tolerance in terms of fitting period. As s comparison, the RPM system showed 66% agreement within ±5% tolerance, and 65% for the RGSC versus RPM measurements. Conclusions New functions and positioning accuracy improve the RGSC system’s ability to achieve higher dynamic treatment precision. A 4D phantom is helpful for the QA tests. Further investigation is required for the whole RGSC system performance QA. PMID:29722356

  4. Optimization of the German integrated information and measurement system (IMIS)

    International Nuclear Information System (INIS)

    Wirth, E.; Weiss, W.

    2002-01-01

    The Chernobyl accident led to a widespread contamination of the environment in most European countries. In Germany, like in all other countries, it took some time to evaluate the radiological situation, time which is extremely valuable in the early phases of an accident when decisions on countermeasures like sheltering, iodine prophylaxis or evacuation have to be taken. For a better emergency preparedness the Integrated Information and Measurement System (IMIS) has been developed and established in Germany. In case of a widespread contamination of the environment, the system will provide the decision makers with all information necessary to evaluate the radiological situation and to decide on countermeasures. Presently this system is upgraded due to the adoption of the European decision supporting system RODOS and by the improvement of the national information exchange. For this purpose the web based information system ELAN has been developed. The national systems have to be integrated into the European and international communication systems. In this presentation the IMIS system is briefly described and the new features and modules of the system are discussed in greater detail

  5. The Technology of Measurement Feedback Systems.

    Science.gov (United States)

    Bickman, Leonard; Kelley, Susan Douglas; Athay, Michele

    2012-12-01

    Usual care in the community is far from optimal. Sufficient evidence exists that dropout rates are significant, treatment is effective for only a small proportion of clients, and that the translation of evidence-based treatments to the real world is problematic. Technology has been shown to be helpful in health care in improving the effectiveness of treatment. A relatively new technology being used in mental health is measurement feedback systems (MFSs). MFSs are particularly applicable to couple and family psychology (CFP) because of its ability to provide information on the multiple perspectives involved in treatment. The Contextualized Feedback Systems tm (CFS®), developed at Vanderbilt University is used as an example of what can be accomplished with an MFS. The advantages and limitations of this technology are described as well as the anticipated reimbursement requirements that mental health services will need.

  6. Dual-goniometer system for channeling measurements

    International Nuclear Information System (INIS)

    Linden, M.; Hellborg, R.

    1986-03-01

    This paper describes a two-goniometer system for obtaining azimuthally averaged measurements in channeling experiments. The system consists of a tri-axial master goniometer and a bi-axial goniometer. Both goniometers are controlled by stepping motors. The alignment goniometer has a target holder, which permits the beam spot to be placed anywhere in a 6 x 6 mm 2 square on the target crystal without loosing the target orientation. The design, construction and operation of the goniometers as well as stepping motor control units and programs for computer control of the goniometers are described. Two control programs cover orientation of the target crystal and a number of other normal experimental conditions. (author)

  7. Evaluation of an Automated Keywording System.

    Science.gov (United States)

    Malone, Linda C.; And Others

    1990-01-01

    Discussion of automated indexing techniques focuses on ways to statistically document improvements in the development of an automated keywording system over time. The system developed by the Joint Chiefs of Staff to automate the storage, categorization, and retrieval of information from military exercises is explained, and performance measures are…

  8. Concept Evaluation for Hydraulic Yaw System

    DEFF Research Database (Denmark)

    Stubkier, Søren; Pedersen, Henrik C.; Andersen, Torben Ole

    2013-01-01

    The yaw system is the subsystem on a wind turbine which ensures that the rotor plane of the turbine always is facing the wind direction. Studies from [1] show that a soft yaw system may be utilized to dampen the loads in the wind turbine structure. The soft yaw system operates much like...... investigation. Loads and yaw demands are based on the IEC 61400-1 standard for wind turbine design, and the loads for this examination are extrapolated from the HAWC2 aeroelastic design code. The concepts are based on a 5 MW off-shore turbine....... a suspension system on a car, leading the loads away from the turbine structure. However, to realize a soft hydraulic yaw system a new design concept must be found. As a part of the development of the new concept a preliminary concept evaluation has been conducted, evaluating seven different hydraulic yaw...

  9. Human factors measurement for future air traffic control systems.

    Science.gov (United States)

    Langan-Fox, Janice; Sankey, Michael J; Canty, James M

    2009-10-01

    This article provides a critical review of research pertaining to the measurement of human factors (HF) issues in current and future air traffic control (ATC). Growing worldwide air traffic demands call for a radical departure from current ATC systems. Future systems will have a fundamental impact on the roles and responsibilities of ATC officers (ATCOs). Valid and reliable methods of assessing HF issues associated with these changes, such as a potential increase (or decrease) in workload, are of utmost importance for advancing theory and for designing systems, procedures, and training. We outline major aviation changes and how these relate to five key HF issues in ATC. Measures are outlined, compared, and evaluated and are followed by guidelines for assessing these issues in the ATC domain. Recommendations for future research are presented. A review of the literature suggests that situational awareness and workload have been widely researched and assessed using a variety of measures, but researchers have neglected the areas of trust, stress, and boredom. We make recommendations for use of particular measures and the construction of new measures. It is predicted that, given the changing role of ATCOs and profound future airspace requirements and configurations, issues of stress, trust, and boredom will become more significant. Researchers should develop and/or refine existing measures of all five key HF issues to assess their impact on ATCO performance. Furthermore, these issues should be considered in a holistic manner. The current article provides an evaluation of research and measures used in HF research on ATC that will aid research and ATC measurement.

  10. Evaluating measurement of dynamic constructs: defining a measurement model of derivatives.

    Science.gov (United States)

    Estabrook, Ryne

    2015-03-01

    While measurement evaluation has been embraced as an important step in psychological research, evaluating measurement structures with longitudinal data is fraught with limitations. This article defines and tests a measurement model of derivatives (MMOD), which is designed to assess the measurement structure of latent constructs both for analyses of between-person differences and for the analysis of change. Simulation results indicate that MMOD outperforms existing models for multivariate analysis and provides equivalent fit to data generation models. Additional simulations show MMOD capable of detecting differences in between-person and within-person factor structures. Model features, applications, and future directions are discussed. (c) 2015 APA, all rights reserved).

  11. Fuzzy comprehensive evaluation of district heating systems

    International Nuclear Information System (INIS)

    Wei Bing; Wang Songling; Li Li

    2010-01-01

    Selecting the optimal type of district heating (DH) system is of great importance because different heating systems have different levels of efficiency, which will impact the system economics, environment and energy use. In this study, seven DH systems were analysed and evaluated by the fuzzy comprehensive evaluation method. The dimensionless number-goodness was introduced into the calculation, the economics, environment and energy technology factors were considered synthetically, and the final goodness values were obtained. The results show that if only one of the economics, environment or energy technology factors are considered, different heating systems have different goodness values. When all three factors were taken into account, the final ranking of goodness values was: combined heating and power>gas-fired boiler>water-source heat pump>coal-fired boiler>ground-source heat pump>solar-energy heat pump>oil-fired boiler. The combined heating and power system is the best choice from all seven systems; the gas-fired boiler system is the best of the three boiler systems for heating purpose; and the water-source heat pump is the best of the three heat pump systems for heating and cooling.

  12. Integrated solidity test measurement of the airtight compartment system at the Paks nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Osztheimer, M.; Taubner, R.; Techy, Zs. (Villamosenergiaipari Kutato Intezet, Budapest (Hungary))

    1983-01-01

    A brief report on the purpose of the integrated solidity test measurements of the airtight compartment system of the Paks nuclear power plant and on the applied measuring principles is given. The measuring system and the selected measuring methods are evaluated. The characteristic features of the airtight system of the Paks nuclear power plant's 1st block and their effects on the measurement are mentioned.

  13. Earthquake Ground Motion Measures for Seismic Response Evaluation of Structures

    Energy Technology Data Exchange (ETDEWEB)

    Cho, In-Kil; Ahn, Seong-Moon; Choun, Young-Sun; Seo, Jeong-Moon

    2007-03-15

    This study used the assessment results of failure criteria - base shear, story drift, top acceleration and top displacement - for a PSC containment building subjected to 30 sets of near-fault ground motions to evaluate the earthquake ground motion intensity measures. Seven intensity measures, peak ground acceleration(PGA), peak ground velocity(PGV), spectral acceleration(Sa), velocity(Sv), spectrum intensity for acceleration(SIa), velocity(SIv) and displacement(SId), were used to represent alternative ground motion. The regression analyses of the failure criteria for a PSC containment building were carried out to evaluate a proper intensity measure by using two regression models and seven ground motion parameters. The regression analysis results demonstrate the correlation coefficients of the failure criteria in terms of the candidate IM. From the results, spectral acceleration(Sa) is estimated as the best parameter for a evaluation of the structural safety for a seismic PSA.

  14. NBS measurement system for natural argon-37

    International Nuclear Information System (INIS)

    Currie, L.A.; Lindstrom, R.M.

    1973-01-01

    A project to determine the cosmic-ray production rate and the natural levels of 35-day half-life 37 Ar in the atmosphere has been underway at the National Bureau of Standards for about the past year. The prime objective of this project is to determine the spatial dependence of 37 Ar production in the atmosphere, and the spatial distribution of the naturally-produced 37 Ar (observed concentrations). The results of this study are to be used, in cooperation with L. Machta (National Oceanographic and Atmospheric Administration), to derive information about atmospheric mixing. The purpose of this communication, however, is to present a general description of the various components of the measurement system. As the lowest concentrations of interest are but approximately equal to 10 -3 dpm ( 37 Ar)/l-Ar, very high sensitivity measurement techniques are required. Among the techniques which we have adopted are: quantitative separation of the noble gases from about 1 m 3 of air, using a CaC 2 reactor; gas chromatographic separation of the argon fraction; isotopic enrichment (by a factor of approximately equal to 100) of purified argon; use of specially selected low-level gas proportional counters together with massive shielding and anticoincidence meson cancellation; and the application of pulse discrimination based upon both amplitude (energy) and pulse shape. Finally, on-line computer techniques are being applied for data acquisition and system control

  15. Preparing and evaluating delivery systems for proteins

    DEFF Research Database (Denmark)

    Jorgensen, L; Moeller, E H; van de Weert, M

    2006-01-01

    From a formulation perspective proteins are complex and therefore challenging molecules to develop drug delivery systems for. The success of a formulation depends on the ability of the protein to maintain the native structure and activity during preparation and delivery as well as during shipping...... and long-term storage of the formulation. Therefore, the development and evaluation of successful and promising drug delivery systems is essential. In the present review, some of the particulate drug delivery systems for parenteral delivery of protein are presented and discussed. The challenge...... for incorporation of protein in particulate delivery systems is exemplified by water-in-oil emulsions....

  16. Using the SIMGRO regional hydrological model to evaluate salinity control measures in an irrigation area

    NARCIS (Netherlands)

    Kupper, E.; Querner, E.P.; Morábito, J.A.; Menenti, M.

    2002-01-01

    In irrigated areas with drainage and an important interaction with the groundwater system, it is often difficult to predict effects of measures to control salinity. Therefore, in order to evaluate measures to control salinity the SIMGRO integrated regional hydrological model was extended with a

  17. Evaluation of measures to decrease intra-operative bacterial contamination in orthopaedic implant surgery

    NARCIS (Netherlands)

    Knobben, BAS; van Horn, [No Value; van der Mei, HC; Busscher, HJ

    The aim of this study was to evaluate whether behavioural and systemic measures wilt decrease intra-operative contamination during total hip or knee replacements. The influence of these measures on subsequent prolonged wound discharge, superficial surgical site infection and deep periprosthetic

  18. Course Evaluation Systems for Open-ended Quality Enhancement

    DEFF Research Database (Denmark)

    Piihl, Jesper; Rasmussen, Jens Smed

    2013-01-01

    Quality in higher education is widely controlled through surveys asking students to evaluate teaching. However, control of quality does not necessarily lead to enhancement of quality. Drawing on accounting research and a case study, a measurement-based and open-ended quality control system...... emphasising quality enhancement is suggested. The case shows how interactive use of performance measurement can lead to more engaged and enabling dialogue amongst involved actors concerning quality enhancement, however institutionalised beliefs regarding course evaluation systems makes a change challenging....... The chapter suggests that open-ended measurement systems enabling stakeholders to take responsibility for quality enhancement is not so much a matter of technical design as a matter of an enabling style of use....

  19. Metric Indices for Performance Evaluation of a Mixed Measurement based State Estimator

    Directory of Open Access Journals (Sweden)

    Paula Sofia Vide

    2013-01-01

    Full Text Available With the development of synchronized phasor measurement technology in recent years, it gains great interest the use of PMU measurements to improve state estimation performances due to their synchronized characteristics and high data transmission speed. The ability of the Phasor Measurement Units (PMU to directly measure the system state is a key over SCADA measurement system. PMU measurements are superior to the conventional SCADA measurements in terms of resolution and accuracy. Since the majority of measurements in existing estimators are from conventional SCADA measurement system, it is hard to be fully replaced by PMUs in the near future so state estimators including both phasor and conventional SCADA measurements are being considered. In this paper, a mixed measurement (SCADA and PMU measurements state estimator is proposed. Several useful measures for evaluating various aspects of the performance of the mixed measurement state estimator are proposed and explained. State Estimator validity, performance and characteristics of the results on IEEE 14 bus test system and IEEE 30 bus test system are presented.

  20. Flavor release measurement from gum model system.

    Science.gov (United States)

    Ovejero-López, Isabel; Haahr, Anne-Mette; van den Berg, Frans; Bredie, Wender L P

    2004-12-29

    Flavor release from a mint-flavored chewing gum model system was measured by atmospheric pressure chemical ionization mass spectroscopy (APCI-MS) and sensory time-intensity (TI). A data analysis method for handling the individual curves from both methods is presented. The APCI-MS data are ratio-scaled using the signal from acetone in the breath of subjects. Next, APCI-MS and sensory TI curves are smoothed by low-pass filtering. Principal component analysis of the individual curves is used to display graphically the product differentiation by APCI-MS or TI signals. It is shown that differences in gum composition can be measured by both instrumental and sensory techniques, providing comparable information. The peppermint oil level (0.5-2% w/w) in the gum influenced both the retronasal concentration and the perceived peppermint flavor. The sweeteners' (sorbitol or xylitol) effect is less apparent. Sensory adaptation and sensitivity differences of human perception versus APCI-MS detection might explain the divergence between the two dynamic measurement methods.