WorldWideScience

Sample records for measured variables included

  1. Variable screening and ranking using sampling-based sensitivity measures

    International Nuclear Information System (INIS)

    Wu, Y-T.; Mohanty, Sitakanta

    2006-01-01

    This paper presents a methodology for screening insignificant random variables and ranking significant important random variables using sensitivity measures including two cumulative distribution function (CDF)-based and two mean-response based measures. The methodology features (1) using random samples to compute sensitivities and (2) using acceptance limits, derived from the test-of-hypothesis, to classify significant and insignificant random variables. Because no approximation is needed in either the form of the performance functions or the type of continuous distribution functions representing input variables, the sampling-based approach can handle highly nonlinear functions with non-normal variables. The main characteristics and effectiveness of the sampling-based sensitivity measures are investigated using both simple and complex examples. Because the number of samples needed does not depend on the number of variables, the methodology appears to be particularly suitable for problems with large, complex models that have large numbers of random variables but relatively few numbers of significant random variables

  2. Seasonal Variability in European Radon Measurements

    Science.gov (United States)

    Groves-Kirkby, C. J.; Denman, A. R.; Phillips, P. S.; Crockett, R. G. M.; Sinclair, J. M.

    2009-04-01

    In temperate climates, domestic radon concentration levels are generally seasonally dependent, the level in the home reflecting the convolution of two time-dependent functions. These are the source soil-gas radon concentration itself, and the principal force driving radon into the building from the soil, namely the pressure-difference between interior and exterior environment. While the meteorological influence can be regarded as relatively uniform on a European scale, its variability being defined largely by the influence of North-Atlantic weather systems, soil-gas radon is generally more variable as it is essentially geologically dependent. Seasonal variability of domestic radon concentration can therefore be expected to exhibit geographical variability, as is indeed the case. To compensate for the variability of domestic radon levels when assessing the long term radon health risks, the results of individual short-term measurements are generally converted to equivalent mean annual levels by application of a Seasonal Correction Factor (SCF). This is a multiplying factor, typically derived from measurements of a large number of homes, applied to the measured short-term radon concentration to provide a meaningful annual mean concentration for dose-estimation purposes. Following concern as to the universal applicability of a single SCF set, detailed studies in both the UK and France have reported location-specific SCF sets for different regions of each country. Further results indicate that SCFs applicable to the UK differ significantly from those applicable elsewhere in Europe and North America in both amplitude and phase, supporting the thesis that seasonal variability in indoor radon concentration cannot realistically be compensated for by a single national or international SCF scheme. Published data characterising the seasonal variability of European national domestic radon concentrations, has been collated and analysed, with the objective of identifying

  3. Bias in random forest variable importance measures: Illustrations, sources and a solution

    Directory of Open Access Journals (Sweden)

    Hothorn Torsten

    2007-01-01

    Full Text Available Abstract Background Variable importance measures for random forests have been receiving increased attention as a means of variable selection in many classification tasks in bioinformatics and related scientific fields, for instance to select a subset of genetic markers relevant for the prediction of a certain disease. We show that random forest variable importance measures are a sensible means for variable selection in many applications, but are not reliable in situations where potential predictor variables vary in their scale of measurement or their number of categories. This is particularly important in genomics and computational biology, where predictors often include variables of different types, for example when predictors include both sequence data and continuous variables such as folding energy, or when amino acid sequence data show different numbers of categories. Results Simulation studies are presented illustrating that, when random forest variable importance measures are used with data of varying types, the results are misleading because suboptimal predictor variables may be artificially preferred in variable selection. The two mechanisms underlying this deficiency are biased variable selection in the individual classification trees used to build the random forest on one hand, and effects induced by bootstrap sampling with replacement on the other hand. Conclusion We propose to employ an alternative implementation of random forests, that provides unbiased variable selection in the individual classification trees. When this method is applied using subsampling without replacement, the resulting variable importance measures can be used reliably for variable selection even in situations where the potential predictor variables vary in their scale of measurement or their number of categories. The usage of both random forest algorithms and their variable importance measures in the R system for statistical computing is illustrated and

  4. Clarifying the use of aggregated exposures in multilevel models: self-included vs. self-excluded measures.

    Directory of Open Access Journals (Sweden)

    Etsuji Suzuki

    Full Text Available Multilevel analyses are ideally suited to assess the effects of ecological (higher level and individual (lower level exposure variables simultaneously. In applying such analyses to measures of ecologies in epidemiological studies, individual variables are usually aggregated into the higher level unit. Typically, the aggregated measure includes responses of every individual belonging to that group (i.e. it constitutes a self-included measure. More recently, researchers have developed an aggregate measure which excludes the response of the individual to whom the aggregate measure is linked (i.e. a self-excluded measure. In this study, we clarify the substantive and technical properties of these two measures when they are used as exposures in multilevel models.Although the differences between the two aggregated measures are mathematically subtle, distinguishing between them is important in terms of the specific scientific questions to be addressed. We then show how these measures can be used in two distinct types of multilevel models-self-included model and self-excluded model-and interpret the parameters in each model by imposing hypothetical interventions. The concept is tested on empirical data of workplace social capital and employees' systolic blood pressure.Researchers assume group-level interventions when using a self-included model, and individual-level interventions when using a self-excluded model. Analytical re-parameterizations of these two models highlight their differences in parameter interpretation. Cluster-mean centered self-included models enable researchers to decompose the collective effect into its within- and between-group components. The benefit of cluster-mean centering procedure is further discussed in terms of hypothetical interventions.When investigating the potential roles of aggregated variables, researchers should carefully explore which type of model-self-included or self-excluded-is suitable for a given situation

  5. Variable reflectivity signal mirrors and signal response measurements

    International Nuclear Information System (INIS)

    Vine, Glenn de; Shaddock, Daniel A; McClelland, David E

    2002-01-01

    Future gravitational wave detectors will include some form of signal mirror in order to alter the signal response of the device. We introduce interferometer configurations which utilize a variable reflectivity signal mirror allowing a tunable peak frequency and variable signal bandwidth. A detector configured with a Fabry-Perot cavity as the signal mirror is compared theoretically with one using a Michelson interferometer for a signal mirror. A system for the measurement of the interferometer signal responses is introduced. This technique is applied to a power-recycled Michelson interferometer with resonant sideband extraction. We present broadband measurements of the benchtop prototype's signal response for a range of signal cavity detunings. This technique is also applicable to most other gravitational wave detector configurations

  6. Variable reflectivity signal mirrors and signal response measurements

    CERN Document Server

    Vine, G D; McClelland, D E

    2002-01-01

    Future gravitational wave detectors will include some form of signal mirror in order to alter the signal response of the device. We introduce interferometer configurations which utilize a variable reflectivity signal mirror allowing a tunable peak frequency and variable signal bandwidth. A detector configured with a Fabry-Perot cavity as the signal mirror is compared theoretically with one using a Michelson interferometer for a signal mirror. A system for the measurement of the interferometer signal responses is introduced. This technique is applied to a power-recycled Michelson interferometer with resonant sideband extraction. We present broadband measurements of the benchtop prototype's signal response for a range of signal cavity detunings. This technique is also applicable to most other gravitational wave detector configurations.

  7. The variability of piezoelectric measurements. Material and measurement method contributions

    International Nuclear Information System (INIS)

    Stewart, M.; Cain, M.

    2002-01-01

    The variability of piezoelectric materials measurements has been investigated in order to separate the contributions from intrinsic instrumental variability, and the contributions from the variability in materials. The work has pinpointed several areas where weaknesses in the measurement methods result in high variability, and also show that good correlation between piezoelectric parameters allow simpler measurement methods to be used. The Berlincourt method has been shown to be unreliable when testing thin discs, however when testing thicker samples there is a good correlation between this and other methods. The high field permittivity and low field permittivity correlate well, so tolerances on low field measurements would predict high field performance. In trying to identify microstructural origins of samples that behave differently to others within a batch, no direct evidence was found to suggest that outliers originate from either differences in microstructure or crystallography. Some of the samples chosen as maximum outliers showed pin-holes, probably from electrical breakdown during poling, even though these defects would ordinarily be detrimental to piezoelectric output. (author)

  8. A Case for Including Atmospheric Thermodynamic Variables in Wind Turbine Fatigue Loading Parameter Identification

    International Nuclear Information System (INIS)

    Kelley, Neil D.

    1999-01-01

    This paper makes the case for establishing efficient predictor variables for atmospheric thermodynamics that can be used to statistically correlate the fatigue accumulation seen on wind turbines. Recently, two approaches to this issue have been reported. One uses multiple linear-regression analysis to establish the relative causality between a number of predictors related to the turbulent inflow and turbine loads. The other approach, using many of the same predictors, applies the technique of principal component analysis. An examination of the ensemble of predictor variables revealed that they were all kinematic in nature; i.e., they were only related to the description of the velocity field. Boundary-layer turbulence dynamics depends upon a description of the thermal field and its interaction with the velocity distribution. We used a series of measurements taken within a multi-row wind farm to demonstrate the need to include atmospheric thermodynamic variables as well as velocity-related ones in the search for efficient turbulence loading predictors in various turbine-operating environments. Our results show that a combination of vertical stability and hub-height mean shearing stress variables meet this need over a period of 10 minutes

  9. Measures of the sheep-goat variable, transliminality, and their correlates.

    Science.gov (United States)

    Thalbourne, M A

    2001-04-01

    In this study a battery of pencil-and-paper tests was given to 125 first-year psychology students (27% men). This battery included as measures of belief in the paranormal (the so-called "sheep-goat variable") the Australian Sheep-Goat Scale, Tobacyk's Revised Paranormal Belief Scale (comprised of two scales--New Age Philosophy and Traditional Paranormal Beliefs), and the Anomalous Experience Inventory (comprised of five scales: Anomalous/Paranormal Experience, Belief, Ability, Fear, and Drug Use). Also included were the 29-item Transliminality Scale, a 35-item Kundalini Scale, an experimental 13-item Determinism/Free Will scale, and a number of single-question items aimed specifically at transliminality. The results were, first, that virtually all the measures of the sheep-goat variable were intercorrelated with each other (range, .34 to .77), thereby providing support for their convergent validity. Second, scores on the Kundalini Scale and Drug Use correlated significantly with scores on the sheep-goat variable, replicating previous findings. And, finally, many correlates of transliminality were found, again including scores on the Kundalini Scale and Drug Use (prescribed and illicit) as well as certain determinism-related beliefs. Beliefs, experiences, and behaviors associated with transliminality and the Kundalini experience may reflect a desire to escape a negative state of being.

  10. Kiloampere, Variable-Temperature, Critical-Current Measurements of High-Field Superconductors.

    Science.gov (United States)

    Goodrich, L F; Cheggour, N; Stauffer, T C; Filla, B J; Lu, X F

    2013-01-01

    K to those measured on the same specimen in flowing helium gas ("gas" or I c gas) at the same temperature. These comparisons indicate the temperature control is effective over the superconducting wire length between the voltage taps, and this condition is valid for all types of sample investigated, including Nb-Ti, Nb3Sn, and MgB2 wires. The liquid/gas comparisons are used to study the variable-temperature measurement protocol that was necessary to obtain the "correct" critical current, which was assumed to be the I c liq. We also calibrated the magnetoresistance effect of resistive thermometers for temperatures from 4 K to 35 K and magnetic fields from 0 T to 16 T. This calibration reduces systematic errors in the variable-temperature data, but it does not affect the liquid/gas comparison since the same thermometers are used in both cases.

  11. MEASUREMENT OPTIMALIZATION OF ZAKAT DISTRIBUTION AT LEMBAGA AMIL ZAKAT USING VARIABLE MEASUREMENT OF ECONOMY

    Directory of Open Access Journals (Sweden)

    Marissa Haque

    2016-09-01

    Full Text Available The aim of this research conducted is to optimalize the zakat distribution using economy variabel measurement. Design/Metodology. The Quantitative Research Method is used to analyze financial data, with Optimalize Model as Z variable design, Measurement of Economy as Y variable and Objective Output as X variable, using AMOS program and SEM as tool analysis to confirm that the model can be used as a measurement tool. Research result. Using some indicators to analyze every variable, obtaining output and objective result, influence optimalization of measurement of economy. Conclusion. The measurement of optimalization of zakat distribution using measurement of economy variable, with independent variable/output exogenous and objective, can be used as a model to measure Lembaga Amil Zakat performance. Furthermore, this research need to have some indicators’ development especially in the area of objective variable. Key words:   Output, Objective, Measurement of Economy, Distribution Optimalization, Zakat JEL Classification: D64

  12. Gait variability measurements in lumbar spinal stenosis patients: part B. Preoperative versus postoperative gait variability

    International Nuclear Information System (INIS)

    Papadakis, N C; Christakis, D G; Tzagarakis, G N; Chlouverakis, G I; Kampanis, N A; Stergiopoulos, K N; Katonis, P G

    2009-01-01

    The objective of this study was to assess the gait variability of lumbar spinal stenosis (LSS) patients and to evaluate its postoperative progression. The hypothesis was that LSS patients' preoperative gait variability in the frequency domain was higher than the corresponding postoperative. A tri-axial accelerometer sensor was used for the gait measurement and a spectral differential entropy algorithm was used to measure the gait variability. Twelve subjects with LSS were measured before and after surgery. Preoperative measurements were performed 2 days before surgery. Postoperative measurements were performed 6 and 12 months after surgery. Preoperative gait variability was higher than the corresponding postoperative. Also, in most cases, gait variability appeared to decrease throughout the year

  13. Bell inequalities for continuous-variable measurements

    International Nuclear Information System (INIS)

    He, Q. Y.; Reid, M. D.; Drummond, P. D.; Cavalcanti, E. G.

    2010-01-01

    Tests of local hidden-variable theories using measurements with continuous-variable (CV) outcomes are developed, and a comparison of different methods is presented. As examples, we focus on multipartite entangled Greenberger-Horne-Zeilinger and cluster states. We suggest a physical process that produces the states proposed here, and investigate experiments both with and without binning of the continuous variable. In the former case, the Mermin-Klyshko inequalities can be used directly. For unbinned outcomes, the moment-based Cavalcanti-Foster-Reid-Drummond inequalities are extended to functional inequalities by consideration of arbitrary functions of the measurements at each site. By optimizing these functions, we obtain more robust violations of local hidden-variable theories than with either binning or moments. Recent inequalities based on the algebra of quaternions and octonions are compared with these methods. Since the prime advantage of CV experiments is to provide a route to highly efficient detection via homodyne measurements, we analyze the effect of noise and detection losses in both binned and unbinned cases. The CV moment inequalities with an optimal function have greater robustness to both loss and noise. This could permit a loophole-free test of Bell inequalities.

  14. Additive measures of travel time variability

    DEFF Research Database (Denmark)

    Engelson, Leonid; Fosgerau, Mogens

    2011-01-01

    This paper derives a measure of travel time variability for travellers equipped with scheduling preferences defined in terms of time-varying utility rates, and who choose departure time optimally. The corresponding value of travel time variability is a constant that depends only on preference...... parameters. The measure is unique in being additive with respect to independent parts of a trip. It has the variance of travel time as a special case. Extension is provided to the case of travellers who use a scheduled service with fixed headway....

  15. Taylor Series Trajectory Calculations Including Oblateness Effects and Variable Atmospheric Density

    Science.gov (United States)

    Scott, James R.

    2011-01-01

    Taylor series integration is implemented in NASA Glenn's Spacecraft N-body Analysis Program, and compared head-to-head with the code's existing 8th- order Runge-Kutta Fehlberg time integration scheme. This paper focuses on trajectory problems that include oblateness and/or variable atmospheric density. Taylor series is shown to be significantly faster and more accurate for oblateness problems up through a 4x4 field, with speedups ranging from a factor of 2 to 13. For problems with variable atmospheric density, speedups average 24 for atmospheric density alone, and average 1.6 to 8.2 when density and oblateness are combined.

  16. SALTSTONE VARIABILITY STUDY - MEASUREMENT OF POROSITY

    International Nuclear Information System (INIS)

    Harbour, J; Vickie Williams, V; Tommy Edwards, T; Russell Eibling, R; Ray Schumacher, R

    2007-01-01

    made from either Modular Caustic Side Solvent Extraction Unit (MCU) or Salt Waste Processing Facility (SWPF) simulants in premix, the porosities averaged near 62 % with an uptake of water through hydration reactions equivalent to a water to cementitious materials ratio (w/cm) of 0.04. For a mix made from a Deliquification, Dissolution and Adjustment (DDA) simulant and premix, the porosity is slightly lower at 57 % with an uptake of water through hydration reactions equivalent to a w/cm ratio of 0.07. Data are presented which demonstrate that porosity is inversely related to the heat of hydration, a measure of the extent of the hydration reactions. Modeling of porosities from three of the statistically designed phases of the Saltstone Variability Study demonstrated that the data could be fit to a linear model with an R2 of 0.74 and no statistical evidence for a lack of fit. The model revealed that w/cm ratio plays a significant role in the total porosity with porosity increasing as the w/cm ratio increases. Other elements of the model include positive correlations with the free hydroxide ion concentration and the total nitrate plus nitrite ion concentration. For a series of mixes in which the composition of the salt solution remained constant (MCU baseline) the porosity increased from ∼60 to 65 % as the w/cm ratio increased from 0.55 to 0.65

  17. Bayesian modeling of measurement error in predictor variables

    NARCIS (Netherlands)

    Fox, Gerardus J.A.; Glas, Cornelis A.W.

    2003-01-01

    It is shown that measurement error in predictor variables can be modeled using item response theory (IRT). The predictor variables, that may be defined at any level of an hierarchical regression model, are treated as latent variables. The normal ogive model is used to describe the relation between

  18. Volume measurement variability in three-dimensional high-frequency ultrasound images of murine liver metastases

    International Nuclear Information System (INIS)

    Wirtzfeld, L A; Graham, K C; Groom, A C; MacDonald, I C; Chambers, A F; Fenster, A; Lacefield, J C

    2006-01-01

    The identification and quantification of tumour volume measurement variability is imperative for proper study design of longitudinal non-invasive imaging of pre-clinical mouse models of cancer. Measurement variability will dictate the minimum detectable volume change, which in turn influences the scheduling of imaging sessions and the interpretation of observed changes in tumour volume. In this paper, variability is quantified for tumour volume measurements from 3D high-frequency ultrasound images of murine liver metastases. Experimental B16F1 liver metastases were analysed in different size ranges including less than 1 mm 3 , 1-4 mm 3 , 4-8 mm 3 and 8-70 mm 3 . The intra- and inter-observer repeatability was high over a large range of tumour volumes, but the coefficients of variation (COV) varied over the volume ranges. The minimum and maximum intra-observer COV were 4% and 14% for the 1-4 mm 3 and 3 tumours, respectively. For tumour volumes measured by segmenting parallel planes, the maximum inter-slice distance that maintained acceptable measurement variability increased from 100 to 600 μm as tumour volume increased. Comparison of free breathing versus ventilated animals demonstrated that respiratory motion did not significantly change the measured volume. These results enable design of more efficient imaging studies by using the measured variability to estimate the time required to observe a significant change in tumour volume

  19. Measuring Variability in the Presence of Noise

    Science.gov (United States)

    Welsh, W. F.

    Quantitative measurements of a variable signal in the presence of noise requires very careful attention to subtle affects which can easily bias the measurements. This is not limited to the low-count rate regime, nor is the bias error necessarily small. In this talk I will mention some of the dangers in applying standard techniques which are appropriate for high signal to noise data but fail in the cases where the S/N is low. I will discuss methods for correcting the bias in the these cases, both for periodic and non-periodic variability, and will introduce the concept of the ``filtered de-biased RMS''. I will also illustrate some common abuses of power spectrum interpretation. All of these points will be illustrated with examples from recent work on CV and AGN variability.

  20. Blood Pressure Variability and Cognitive Function Among Older African Americans: Introducing a New Blood Pressure Variability Measure.

    Science.gov (United States)

    Tsang, Siny; Sperling, Scott A; Park, Moon Ho; Helenius, Ira M; Williams, Ishan C; Manning, Carol

    2017-09-01

    Although blood pressure (BP) variability has been reported to be associated with cognitive impairment, whether this relationship affects African Americans has been unclear. We sought correlations between systolic and diastolic BP variability and cognitive function in community-dwelling older African Americans, and introduced a new BP variability measure that can be applied to BP data collected in clinical practice. We assessed cognitive function in 94 cognitively normal older African Americans using the Mini-Mental State Examination (MMSE) and the Computer Assessment of Mild Cognitive Impairment (CAMCI). We used BP measurements taken at the patients' three most recent primary care clinic visits to generate three traditional BP variability indices, range, standard deviation, and coefficient of variation, plus a new index, random slope, which accounts for unequal BP measurement intervals within and across patients. MMSE scores did not correlate with any of the BP variability indices. Patients with greater diastolic BP variability were less accurate on the CAMCI verbal memory and incidental memory tasks. Results were similar across the four BP variability indices. In a sample of cognitively intact older African American adults, BP variability did not correlate with global cognitive function, as measured by the MMSE. However, higher diastolic BP variability correlated with poorer verbal and incidental memory. By accounting for differences in BP measurement intervals, our new BP variability index may help alert primary care physicians to patients at particular risk for cognitive decline.

  1. Measurement-Device Independency Analysis of Continuous-Variable Quantum Digital Signature

    Directory of Open Access Journals (Sweden)

    Tao Shang

    2018-04-01

    Full Text Available With the practical implementation of continuous-variable quantum cryptographic protocols, security problems resulting from measurement-device loopholes are being given increasing attention. At present, research on measurement-device independency analysis is limited in quantum key distribution protocols, while there exist different security problems for different protocols. Considering the importance of quantum digital signature in quantum cryptography, in this paper, we attempt to analyze the measurement-device independency of continuous-variable quantum digital signature, especially continuous-variable quantum homomorphic signature. Firstly, we calculate the upper bound of the error rate of a protocol. If it is negligible on condition that all measurement devices are untrusted, the protocol is deemed to be measurement-device-independent. Then, we simplify the calculation by using the characteristics of continuous variables and prove the measurement-device independency of the protocol according to the calculation result. In addition, the proposed analysis method can be extended to other quantum cryptographic protocols besides continuous-variable quantum homomorphic signature.

  2. Measuring the surgical 'learning curve': methods, variables and competency.

    Science.gov (United States)

    Khan, Nuzhath; Abboudi, Hamid; Khan, Mohammed Shamim; Dasgupta, Prokar; Ahmed, Kamran

    2014-03-01

    To describe how learning curves are measured and what procedural variables are used to establish a 'learning curve' (LC). To assess whether LCs are a valuable measure of competency. A review of the surgical literature pertaining to LCs was conducted using the Medline and OVID databases. Variables should be fully defined and when possible, patient-specific variables should be used. Trainee's prior experience and level of supervision should be quantified; the case mix and complexity should ideally be constant. Logistic regression may be used to control for confounding variables. Ideally, a learning plateau should reach a predefined/expert-derived competency level, which should be fully defined. When the group splitting method is used, smaller cohorts should be used in order to narrow the range of the LC. Simulation technology and competence-based objective assessments may be used in training and assessment in LC studies. Measuring the surgical LC has potential benefits for patient safety and surgical education. However, standardisation in the methods and variables used to measure LCs is required. Confounding variables, such as participant's prior experience, case mix, difficulty of procedures and level of supervision, should be controlled. Competency and expert performance should be fully defined. © 2013 The Authors. BJU International © 2013 BJU International.

  3. Disaggregating measurement uncertainty from population variability and Bayesian treatment of uncensored results

    International Nuclear Information System (INIS)

    Strom, Daniel J.; Joyce, Kevin E.; Maclellan, Jay A.; Watson, David J.; Lynch, Timothy P.; Antonio, Cheryl L.; Birchall, Alan; Anderson, Kevin K.; Zharov, Peter

    2012-01-01

    In making low-level radioactivity measurements of populations, it is commonly observed that a substantial portion of net results are negative. Furthermore, the observed variance of the measurement results arises from a combination of measurement uncertainty and population variability. This paper presents a method for disaggregating measurement uncertainty from population variability to produce a probability density function (PDF) of possibly true results. To do this, simple, justifiable, and reasonable assumptions are made about the relationship of the measurements to the measurands (the 'true values'). The measurements are assumed to be unbiased, that is, that their average value is the average of the measurands. Using traditional estimates of each measurement's uncertainty to disaggregate population variability from measurement uncertainty, a PDF of measurands for the population is produced. Then, using Bayes's theorem, the same assumptions, and all the data from the population of individuals, a prior PDF is computed for each individual's measurand. These PDFs are non-negative, and their average is equal to the average of the measurement results for the population. The uncertainty in these Bayesian posterior PDFs is all Berkson with no remaining classical component. The methods are applied to baseline bioassay data from the Hanford site. The data include 90Sr urinalysis measurements on 128 people, 137Cs in vivo measurements on 5,337 people, and 239Pu urinalysis measurements on 3,270 people. The method produces excellent results for the 90Sr and 137Cs measurements, since there are nonzero concentrations of these global fallout radionuclides in people who have not been occupationally exposed. The method does not work for the 239Pu measurements in non-occupationally exposed people because the population average is essentially zero.

  4. Beta activity measurements in high, variable gamma backgrounds

    International Nuclear Information System (INIS)

    Stanga, D.; Sandu, E.; Craciun, L.

    1997-01-01

    In many cases beta activity measurements must be performed in high and variable gamma backgrounds. In such instances it is necessary to use well-shielded detectors but this technique is limited to laboratory equipment and frequently insufficient. In order to perform in a simple manner beta activity measurements in high and variable backgrounds a software-aided counting technique have been developed and a counting system have been constructed. This technique combines the different counting techniques with traditional method of successive measurement of the sample and background. The counting system is based on a programmable multi-scaler which is endowed with appropriate software and allow all operations to be performed via keyboard in an interactive fashion. Two large - area proportional detectors were selected in order to have the same background and the same gamma response within 5%. A program has been developed for the counting data analysis and beta activity computing. The software-aided counting technique has been implemented for beta activity measurement in high and variable backgrounds. (authors)

  5. Stepwise data envelopment analysis (DEA); choosing variables for measuring technical efficiency in Norwegian electricity distribution

    International Nuclear Information System (INIS)

    Kittelsen, S.A.C.

    1993-04-01

    Electric power distribution is an activity that in principle delivers a separate product to each customer. A specification of products for a utility as a whole leads potentially to a large number of product aspects including topographic and climatic conditions, and the level of disaggregation of factors and products may give the production and cost functions a high dimensionality. Some aggregation is therefore necessary. Non-parametric methods like Data Envelopment Analysis (DEA) have the advantage that they may give meaningful results when parametric methods would not have enough degrees of freedom, but will have related problems if the variables are collinear or are irrelevant. Although aggregate efficiency measures will not be much affected, rates of transformation will be corrupted and observations with extreme values may be measured as efficient by default. Little work has been done so far on the statistical properties of the non-parametric efficiency measure. This paper utilizes a suggestion by Rajiv Banker to measure the significance of the change in results when disaggregating or introducing an extra variable, and shows how one can let the data participate in deciding which variables should be included in the analysis. 32 refs., 7 figs., 4 tabs

  6. Quantifying measurement uncertainty and spatial variability in the context of model evaluation

    Science.gov (United States)

    Choukulkar, A.; Brewer, A.; Pichugina, Y. L.; Bonin, T.; Banta, R. M.; Sandberg, S.; Weickmann, A. M.; Djalalova, I.; McCaffrey, K.; Bianco, L.; Wilczak, J. M.; Newman, J. F.; Draxl, C.; Lundquist, J. K.; Wharton, S.; Olson, J.; Kenyon, J.; Marquis, M.

    2017-12-01

    In an effort to improve wind forecasts for the wind energy sector, the Department of Energy and the NOAA funded the second Wind Forecast Improvement Project (WFIP2). As part of the WFIP2 field campaign, a large suite of in-situ and remote sensing instrumentation was deployed to the Columbia River Gorge in Oregon and Washington from October 2015 - March 2017. The array of instrumentation deployed included 915-MHz wind profiling radars, sodars, wind- profiling lidars, and scanning lidars. The role of these instruments was to provide wind measurements at high spatial and temporal resolution for model evaluation and improvement of model physics. To properly determine model errors, the uncertainties in instrument-model comparisons need to be quantified accurately. These uncertainties arise from several factors such as measurement uncertainty, spatial variability, and interpolation of model output to instrument locations, to name a few. In this presentation, we will introduce a formalism to quantify measurement uncertainty and spatial variability. The accuracy of this formalism will be tested using existing datasets such as the eXperimental Planetary boundary layer Instrumentation Assessment (XPIA) campaign. Finally, the uncertainties in wind measurement and the spatial variability estimates from the WFIP2 field campaign will be discussed to understand the challenges involved in model evaluation.

  7. Violation of Bell's Inequality Using Continuous Variable Measurements

    Science.gov (United States)

    Thearle, Oliver; Janousek, Jiri; Armstrong, Seiji; Hosseini, Sara; Schünemann Mraz, Melanie; Assad, Syed; Symul, Thomas; James, Matthew R.; Huntington, Elanor; Ralph, Timothy C.; Lam, Ping Koy

    2018-01-01

    A Bell inequality is a fundamental test to rule out local hidden variable model descriptions of correlations between two physically separated systems. There have been a number of experiments in which a Bell inequality has been violated using discrete-variable systems. We demonstrate a violation of Bell's inequality using continuous variable quadrature measurements. By creating a four-mode entangled state with homodyne detection, we recorded a clear violation with a Bell value of B =2.31 ±0.02 . This opens new possibilities for using continuous variable states for device independent quantum protocols.

  8. Impact of including surface currents on simulation of Indian Ocean variability with the POAMA coupled model

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Mei; Wang, Guomin; Hendon, Harry H.; Alves, Oscar [Bureau of Meteorology, Centre for Australian Weather and Climate Research, Melbourne (Australia)

    2011-04-15

    Impacts on the coupled variability of the Indo-Pacific by including the effects of surface currents on surface stress are explored in four extended integrations of an experimental version of the Bureau of Meteorology's coupled seasonal forecast model POAMA. The first pair of simulations differs only in their treatment of momentum coupling: one version includes the effects of surface currents on the surface stress computation and the other does not. The version that includes the effect of surface currents has less mean-state bias in the equatorial Pacific cold tongue but produces relatively weak coupled variability in the Tropics, especially that related to the Indian Ocean dipole (IOD) and El Nino/Southern Oscillation (ENSO). The version without the effects of surface currents has greater bias in the Pacific cold tongue but stronger IOD and ENSO variability. In order to diagnose the role of changes in local coupling from changes in remote forcing by ENSO for causing changes in IOD variability, a second set of simulations is conducted where effects of surface currents are included only in the Indian Ocean and only in the Pacific Ocean. IOD variability is found to be equally reduced by inclusion of the local effects of surface currents in the Indian Ocean and by the reduction of ENSO variability as a result of including effects of surface currents in the Pacific. Some implications of these results for predictability of the IOD and its dependence on ENSO, and for ocean subsurface data assimilation are discussed. (orig.)

  9. Between-centre variability versus variability over time in DXA whole body measurements evaluated using a whole body phantom

    Energy Technology Data Exchange (ETDEWEB)

    Louis, Olivia [Department of Radiology, AZ-VUB, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussel (Belgium)]. E-mail: olivia.louis@az.vub.ac.be; Verlinde, Siska [Belgian Study Group for Pediatric Endocrinology (Belgium); Thomas, Muriel [Belgian Study Group for Pediatric Endocrinology (Belgium); De Schepper, Jean [Department of Pediatrics, AZ-VUB, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussel (Belgium)

    2006-06-15

    This study aimed to compare the variability of whole body measurements, using dual energy X-ray absorptiometry (DXA), among geographically distinct centres versus that over time in a given centre. A Hologic-designed 28 kg modular whole body phantom was used, including high density polyethylene, gray polyvinylchloride and aluminium. It was scanned on seven Hologic QDR 4500 DXA devices, located in seven centres and was also repeatedly (n = 18) scanned in the reference centre, over a time span of 5 months. The mean between-centre coefficient of variation (CV) ranged from 2.0 (lean mass) to 5.6% (fat mass) while the mean within-centre CV ranged from 0.3 (total mass) to 4.7% (total area). Between-centre variability compared well with within-centre variability for total area, bone mineral content and bone mineral density, but was significantly higher for fat (p < 0.001), lean (p < 0.005) and total mass (p < 0.001). Our results suggest that, even when using the same device, the between-centre variability remains a matter of concern, particularly where body composition is concerned.

  10. Measurement of variable magnetic reversal paths in electrically contacted pseudo-spin-valve rings

    International Nuclear Information System (INIS)

    Hayward, T J; Llandro, J; Schackert, F D O; Morecroft, D; Balsod, R B; Bland, J A C; Castano, F J; Ross, C A

    2007-01-01

    In this work we show that the measurement of single magnetic reversal events is of critical importance in order to correctly characterize the switching of magnetic microstructures. Magnetoresistance measurements are performed on two pseudo-spin-valve ring structures with high enough signal to noise to allow the probing of single reversal events. Using this technique we acquire 'switching spectra' which demonstrate that the rings exhibit a range of variable reversal paths, including a bistable reversal mechanism of the hard layer, where the two switching routes have substantially different switching fields. The signature of the variable reversal paths would have been obscured in field cycle averaged data and in the bistable case would cause a fundamental misinterpretation of the reversal behaviour

  11. Comparison of seasonal variability in European domestic radon measurements

    Science.gov (United States)

    Groves-Kirkby, C. J.; Denman, A. R.; Phillips, P. S.; Crockett, R. G. M.; Sinclair, J. M.

    2010-03-01

    Analysis of published data characterising seasonal variability of domestic radon concentrations in Europe and elsewhere shows significant variability between different countries and between regions where regional data is available. Comparison is facilitated by application of the Gini Coefficient methodology to reported seasonal variation data. Overall, radon-rich sedimentary strata, particularly high-porosity limestones, exhibit high seasonal variation, while radon-rich igneous lithologies demonstrate relatively constant, but somewhat higher, radon concentrations. High-variability regions include the Pennines and South Downs in England, Languedoc and Brittany in France, and especially Switzerland. Low-variability high-radon regions include the granite-rich Cornwall/Devon peninsula in England, and Auvergne and Ardennes in France, all components of the Devonian-Carboniferous Hercynian belt.

  12. Comparison of seasonal variability in European domestic radon measurements

    Directory of Open Access Journals (Sweden)

    C. J. Groves-Kirkby

    2010-03-01

    Full Text Available Analysis of published data characterising seasonal variability of domestic radon concentrations in Europe and elsewhere shows significant variability between different countries and between regions where regional data is available. Comparison is facilitated by application of the Gini Coefficient methodology to reported seasonal variation data. Overall, radon-rich sedimentary strata, particularly high-porosity limestones, exhibit high seasonal variation, while radon-rich igneous lithologies demonstrate relatively constant, but somewhat higher, radon concentrations. High-variability regions include the Pennines and South Downs in England, Languedoc and Brittany in France, and especially Switzerland. Low-variability high-radon regions include the granite-rich Cornwall/Devon peninsula in England, and Auvergne and Ardennes in France, all components of the Devonian-Carboniferous Hercynian belt.

  13. Measure of uncertainty in regional grade variability

    NARCIS (Netherlands)

    Tutmez, B.; Kaymak, U.; Melin, P.; Castillo, O.; Gomez Ramirez, E.; Kacprzyk, J.; Pedrycz, W.

    2007-01-01

    Because the geological events are neither homogeneous nor isotropic, the geological investigations are characterized by particularly high uncertainties. This paper presents a hybrid methodology for measuring of uncertainty in regional grade variability. In order to evaluate the fuzziness in grade

  14. Variability of vascular CT measurement techniques used in the assessment abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    England, Andrew; Niker, Amanda; Redmond, Claire

    2010-01-01

    Purpose: The aim of this project is to assess the variability of six CT measurement techniques for sizing abdominal aortic aneurysms (AAAs). Method: 37 CT scans with known AAAs were loaded on to a departmental picture archiving and communication system (PACS). A team of three observers, with experience in aortic CT measurements and the PACS performed a series of 2D and 3D measurements on the abdominal aorta. Each observer was asked to measure 3 quantities; anterior-posterior AAA diameter, maximum oblique AAA diameter, maximum aneurysm area using both 2D and 3D techniques. In order to test intra-observer variability each observer was asked to repeat their measurements. All measurements were taken using electronic callipers, under standardised viewing conditions using previously calibrated equipment. 3D measurements were conducted using a computer generated central luminal line (CLL). All measurements for this group were taken perpendicular to the CLL. Results: A total of 972 independent measurements were recorded by three observers. Mean intra-observer variability was lower for 2D diameter measurements (AP 1.3 ± 1.6 mm; 2D Oblique 1.2 ± 1.3 mm) and 2D areas (0.7 ± 1.3 cm 2 ) when compared to inter-observer variability (AP 1.7 ± 1.9 mm; Oblique 1.6 ± 1.7 mm; area 1.1 ± 1.5 cm 2 ). When comparing 2D with 3D measurements, differences were comparable except for 3D AP diameter and area which had lower inter-observer variability than their 2D counterparts (AP 2D 1.7 ± 1.9 mm, 3D 1.3 ± 1.3 mm; area 2D 1.1 ± 1.5 cm 2 , 3D 0.7 ± 0.7 cm 2 ). 3D area measurement was the only technique which had equal variability for intra- and inter-observer measurements. Overall observer variability for the study was good with 94-100% of all paired measurements within 5.00 mm/cm 2 or less. Using Pitman's test it can be confirmed that area measurements in the 3D plane have the least variability (r = 0.031) and 3D oblique measurements have the highest variability (r = 0

  15. Variability of Measured Runoff and Soil Loss from Field Plots

    Directory of Open Access Journals (Sweden)

    F. Asadzadeh

    2016-02-01

    Full Text Available Introduction: Field plots are widely used in studies related to the measurements of soil loss and modeling of erosion processes. Research efforts are needed to investigate factors affecting the data quality of plots. Spatial scale or size of plots is one of these factors which directly affects measuring runoff and soil loss by means of field plots. The effect of plot size on measured runoff or soil loss from natural plots is known as plot scale effect. On the other hand, variability of runoff and sediment yield from replicated filed plots is a main source of uncertainty in measurement of erosion from plots which should be considered in plot data interpretation processes. Therefore, there is a demand for knowledge of soil erosion processes occurring in plots of different sizes and of factors that determine natural variability, as a basis for obtaining soil loss data of good quality. This study was carried out to investigate the combined effects of these two factors by measurement of runoff and soil loss from replicated plots with different sizes. Materials and Methods: In order to evaluate the variability of runoff and soil loss data seven plots, differing in width and length, were constructed in a uniform slope of 9% at three replicates at Koohin Research Station in Qazvin province. The plots were ploughed up to down slope in September 2011. Each plot was isolated using soil beds with a height of 30 cm, to direct generated surface runoff to the lower part of the plots. Runoff collecting systems composed of gutters, pipes and tankswere installed at the end of each plot. During the two-year study period of 2011-2012, plots were maintained in bare conditions and runoff and soil loss were measured for each single event. Precipitation amounts and characteristics were directly measured by an automatic recording tipping-bucket rain gauge located about 200 m from the experimental plots. The entire runoff volume including eroded sediment was measured on

  16. Input variable selection for data-driven models of Coriolis flowmeters for two-phase flow measurement

    International Nuclear Information System (INIS)

    Wang, Lijuan; Yan, Yong; Wang, Xue; Wang, Tao

    2017-01-01

    Input variable selection is an essential step in the development of data-driven models for environmental, biological and industrial applications. Through input variable selection to eliminate the irrelevant or redundant variables, a suitable subset of variables is identified as the input of a model. Meanwhile, through input variable selection the complexity of the model structure is simplified and the computational efficiency is improved. This paper describes the procedures of the input variable selection for the data-driven models for the measurement of liquid mass flowrate and gas volume fraction under two-phase flow conditions using Coriolis flowmeters. Three advanced input variable selection methods, including partial mutual information (PMI), genetic algorithm-artificial neural network (GA-ANN) and tree-based iterative input selection (IIS) are applied in this study. Typical data-driven models incorporating support vector machine (SVM) are established individually based on the input candidates resulting from the selection methods. The validity of the selection outcomes is assessed through an output performance comparison of the SVM based data-driven models and sensitivity analysis. The validation and analysis results suggest that the input variables selected from the PMI algorithm provide more effective information for the models to measure liquid mass flowrate while the IIS algorithm provides a fewer but more effective variables for the models to predict gas volume fraction. (paper)

  17. Measuring Repeatability of the Focus-variable Lenses

    Directory of Open Access Journals (Sweden)

    Jan Řezníček

    2014-12-01

    Full Text Available In the field of photogrammetry, the optical system, usually represented by the glass lens, is used for metric purposes. Therefore, the aberration characteristics of such a lens, inducing deviations from projective imaging, has to be well known. However, the most important property of the metric lens is the stability of its glass and mechanical elements, ensuring long-term reliability of the measured parameters. In case of a focus-variable lens, the repeatability of the lens setup is important as well. Lenses with a fixed focal length are usually considered as “fixed” though, in fact, most of them contain one or more movable glass elements, providing the focusing function. In cases where the lens is not equipped with fixing screws, the repeatability of the calibration parameters should be known. This paper derives simple mathematical formulas that can be used for measuring the repeatability of the focus-variable lenses, and gives a demonstrative example of such measuring. The given procedure has the advantage that only demanded parameters are estimated, hence, no unwanted correlations with the additional parameters exist. The test arrangement enables us to measure each demanded magnification of the optical system, which is important in close-range photogrammetry.

  18. Mini-UAV based sensory system for measuring environmental variables in greenhouses.

    Science.gov (United States)

    Roldán, Juan Jesús; Joossen, Guillaume; Sanz, David; del Cerro, Jaime; Barrientos, Antonio

    2015-02-02

    This paper describes the design, construction and validation of a mobile sensory platform for greenhouse monitoring. The complete system consists of a sensory system on board a small quadrotor (i.e., a four rotor mini-UAV). The goals of this system include taking measures of temperature, humidity, luminosity and CO2 concentration and plotting maps of these variables. These features could potentially allow for climate control, crop monitoring or failure detection (e.g., a break in a plastic cover). The sensors have been selected by considering the climate and plant growth models and the requirements for their integration onboard the quadrotor. The sensors layout and placement have been determined through a study of quadrotor aerodynamics and the influence of the airflows from its rotors. All components of the system have been developed, integrated and tested through a set of field experiments in a real greenhouse. The primary contributions of this paper are the validation of the quadrotor as a platform for measuring environmental variables and the determination of the optimal location of sensors on a quadrotor.

  19. Mini-UAV Based Sensory System for Measuring Environmental Variables in Greenhouses

    Directory of Open Access Journals (Sweden)

    Juan Jesús Roldán

    2015-02-01

    Full Text Available This paper describes the design, construction and validation of a mobile sensory platform for greenhouse monitoring. The complete system consists of a sensory system on board a small quadrotor (i.e., a four rotor mini-UAV. The goals of this system include taking measures of temperature, humidity, luminosity and CO2 concentration and plotting maps of these variables. These features could potentially allow for climate control, crop monitoring or failure detection (e.g., a break in a plastic cover. The sensors have been selected by considering the climate and plant growth models and the requirements for their integration onboard the quadrotor. The sensors layout and placement have been determined through a study of quadrotor aerodynamics and the influence of the airflows from its rotors. All components of the system have been developed, integrated and tested through a set of field experiments in a real greenhouse. The primary contributions of this paper are the validation of the quadrotor as a platform for measuring environmental variables and the determination of the optimal location of sensors on a quadrotor.

  20. Estimations of natural variability between satellite measurements of trace species concentrations

    Science.gov (United States)

    Sheese, P.; Walker, K. A.; Boone, C. D.; Degenstein, D. A.; Kolonjari, F.; Plummer, D. A.; von Clarmann, T.

    2017-12-01

    In order to validate satellite measurements of atmospheric states, it is necessary to understand the range of random and systematic errors inherent in the measurements. On occasions where the measurements do not agree within those errors, a common "go-to" explanation is that the unexplained difference can be chalked up to "natural variability". However, the expected natural variability is often left ambiguous and rarely quantified. This study will look to quantify the expected natural variability of both O3 and NO2 between two satellite instruments: ACE-FTS (Atmospheric Chemistry Experiment - Fourier Transform Spectrometer) and OSIRIS (Optical Spectrograph and Infrared Imaging System). By sampling the CMAM30 (30-year specified dynamics simulation of the Canadian Middle Atmosphere Model) climate chemistry model throughout the upper troposphere and stratosphere at times and geolocations of coincident ACE-FTS and OSIRIS measurements at varying coincidence criteria, height-dependent expected values of O3 and NO2 variability will be estimated and reported on. The results could also be used to better optimize the coincidence criteria used in satellite measurement validation studies.

  1. Using variable homography to measure emergent fibers on textile fabrics

    Science.gov (United States)

    Xu, Jun; Cudel, Christophe; Kohler, Sophie; Fontaine, Stéphane; Haeberlé, Olivier; Klotz, Marie-Louise

    2011-07-01

    A fabric's smoothness is a key factor to determine the quality of textile finished products and has great influence on the functionality of industrial textiles and high-end textile products. With popularization of the 'zero defect' industrial concept, identifying and measuring defective material in the early stage of production is of great interest for the industry. In the current market, many systems are able to achieve automatic monitoring and control of fabric, paper, and nonwoven material during the entire production process, however online measurement of hairiness is still an open topic and highly desirable for industrial applications. In this paper we propose a computer vision approach, based on variable homography, which can be used to measure the emergent fiber's length on textile fabrics. The main challenges addressed in this paper are the application of variable homography to textile monitoring and measurement, as well as the accuracy of the estimated calculation. We propose that a fibrous structure can be considered as a two-layer structure and then show how variable homography can estimate the length of the fiber defects. Simulations are carried out to show the effectiveness of this method to measure the emergent fiber's length. The true lengths of selected fibers are measured precisely using a digital optical microscope, and then the same fibers are tested by our method. Our experimental results suggest that smoothness monitored by variable homography is an accurate and robust method for quality control of important industrially fabrics.

  2. The cost of travel time variability: three measures with properties

    DEFF Research Database (Denmark)

    Engelson, Leonid; Fosgerau, Mogens

    2016-01-01

    This paper explores the relationships between three types of measures of the cost of travel time variability: measures based on scheduling preferences and implicit departure time choice, Bernoulli type measures based on a univariate function of travel time, and mean-dispersion measures. We...

  3. The gait standard deviation, a single measure of kinematic variability.

    Science.gov (United States)

    Sangeux, Morgan; Passmore, Elyse; Graham, H Kerr; Tirosh, Oren

    2016-05-01

    Measurement of gait kinematic variability provides relevant clinical information in certain conditions affecting the neuromotor control of movement. In this article, we present a measure of overall gait kinematic variability, GaitSD, based on combination of waveforms' standard deviation. The waveform standard deviation is the common numerator in established indices of variability such as Kadaba's coefficient of multiple correlation or Winter's waveform coefficient of variation. Gait data were collected on typically developing children aged 6-17 years. Large number of strides was captured for each child, average 45 (SD: 11) for kinematics and 19 (SD: 5) for kinetics. We used a bootstrap procedure to determine the precision of GaitSD as a function of the number of strides processed. We compared the within-subject, stride-to-stride, variability with the, between-subject, variability of the normative pattern. Finally, we investigated the correlation between age and gait kinematic, kinetic and spatio-temporal variability. In typically developing children, the relative precision of GaitSD was 10% as soon as 6 strides were captured. As a comparison, spatio-temporal parameters required 30 strides to reach the same relative precision. The ratio stride-to-stride divided by normative pattern variability was smaller in kinematic variables (the smallest for pelvic tilt, 28%) than in kinetic and spatio-temporal variables (the largest for normalised stride length, 95%). GaitSD had a strong, negative correlation with age. We show that gait consistency may stabilise only at, or after, skeletal maturity. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Measuring variability of procedure progression in proceduralized scenarios

    International Nuclear Information System (INIS)

    Kim, Yochan; Park, Jinkyun; Jung, Wondea

    2012-01-01

    Highlights: ► The VPP measure was developed to quantify how differently operators follow the procedures. ► Sources that cause variability of ways to follow a given procedure were identified. ► The VPP values for the scenarios are positively related to the scenario performance time. ► The VPP measure is meaningful for explaining characteristics of several PSFs. -- Abstract: Various performance shaping factors (PSFs) have been presented to explain the contributors to unsafe acts in a human failure event or predict a human error probability of new human performance. However, because most of these parameters of an HRA depend on the subjective knowledge and experience of HRA analyzers, the results of an HRA insufficiently provide unbiased standards to explain human performance variations or compare collected data with other data from different analyzers. To secure the validity of the HRA results, we propose a quantitative measure, which represents the variability of procedure progression (VPP) in proceduralized scenarios. A VPP measure shows how differently the operators follow the steps of the procedures. This paper introduces the sources of the VPP measure and relevance to PSFs. The assessment method of the VPP measure is also proposed, and the application examples are shown with a comparison of the performance time. Although more empirical studies should be conducted to reveal the relationship between the VPP measure and other PSFs, it is believed that the VPP measure provides evidence to quantitatively evaluate human performance variations and to cross-culturally compare the collected data.

  5. Measurement of very rapidly variable temperatures

    International Nuclear Information System (INIS)

    Elberg, S.; Mathonnet, P.

    1974-01-01

    Bibliographical research and visits to laboratories were undertaken in order to survey the different techniques used to measure rapidly variable temperatures, specifying the limits in maximum temperature and variation rate (time constant). On the basis of the bibliographical study these techniques were classified in three categories according to the physical meaning of their response time. Extension of the bibliographical research to methods using fast temperature variation measurement techniques and visits to research and industrial laboratories gave in an idea of the problems raised by the application of these methods. The use of these techniques in fields other than those for which they were developed can sometimes be awkward in the case of thermometric probe devices where the time constant cannot generally be specified [fr

  6. Direct-phase-variable model of a synchronous reluctance motor including all slot and winding harmonics

    International Nuclear Information System (INIS)

    Obe, Emeka S.; Binder, A.

    2011-01-01

    A detailed model in direct-phase variables of a synchronous reluctance motor operating at mains voltage and frequency is presented. The model includes the stator and rotor slot openings, the actual winding layout and the reluctance rotor geometry. Hence, all mmf and permeance harmonics are taken into account. It is seen that non-negligible harmonics introduced by slots are present in the inductances computed by the winding function procedure. These harmonics are usually ignored in d-q models. The machine performance is simulated in the stator reference frame to depict the difference between this new direct-phase model including all harmonics and the conventional rotor reference frame d-q model. Saturation is included by using a polynomial fitting the variation of d-axis inductance with stator current obtained by finite-element software FEMAG DC (registered) . The detailed phase-variable model can yield torque pulsations comparable to those obtained from finite elements while the d-q model cannot.

  7. Measures of Quantum Synchronization in Continuous Variable Systems

    Science.gov (United States)

    Mari, A.; Farace, A.; Didier, N.; Giovannetti, V.; Fazio, R.

    2013-09-01

    We introduce and characterize two different measures which quantify the level of synchronization of coupled continuous variable quantum systems. The two measures allow us to extend to the quantum domain the notions of complete and phase synchronization. The Heisenberg principle sets a universal bound to complete synchronization. The measure of phase synchronization is, in principle, unbounded; however, in the absence of quantum resources (e.g., squeezing) the synchronization level is bounded below a certain threshold. We elucidate some interesting connections between entanglement and synchronization and, finally, discuss an application based on quantum optomechanical systems.

  8. Observer variability of lung function measurements in 2-6-yr-old children

    DEFF Research Database (Denmark)

    Klug, B; Nielsen, K G; Bisgaard, H

    2000-01-01

    by the interrupter technique measurements in young children are subject to influence by the observer, and the random variability between observers appears to be particularly great for respiratory resistance assessed by the interrupter technique. The authors suggest that the between-observer variability should......The aim of this study was to assess the within-observer and between-observer variability of lung function measurements in children aged 2-6 yrs. Two observers examined 22 asthmatic children independently according to a predefined protocol. Each observer obtained duplicate measurements...... observers. The ratio SDw between observers/mean SDw within observers was 0.94, 1.25, 1.35 and 2.86 for Xrs,5, Rrs,5, sRaw and Rint, respectively, indicating greater between-observer variability of the latter. The systematic difference between observers assessed by the difference between observer means...

  9. Association between different measurements of blood pressure variability by ABP monitoring and ankle-brachial index.

    Science.gov (United States)

    Wittke, Estefânia; Fuchs, Sandra C; Fuchs, Flávio D; Moreira, Leila B; Ferlin, Elton; Cichelero, Fábio T; Moreira, Carolina M; Neyeloff, Jeruza; Moreira, Marina B; Gus, Miguel

    2010-11-05

    Blood pressure (BP) variability has been associated with cardiovascular outcomes, but there is no consensus about the more effective method to measure it by ambulatory blood pressure monitoring (ABPM). We evaluated the association between three different methods to estimate BP variability by ABPM and the ankle brachial index (ABI). In a cross-sectional study of patients with hypertension, BP variability was estimated by the time rate index (the first derivative of SBP over time), standard deviation (SD) of 24-hour SBP; and coefficient of variability of 24-hour SBP. ABI was measured with a doppler probe. The sample included 425 patients with a mean age of 57 ± 12 years, being 69.2% women, 26.1% current smokers and 22.1% diabetics. Abnormal ABI (≤ 0.90 or ≥ 1.40) was present in 58 patients. The time rate index was 0.516 ± 0.146 mmHg/min in patients with abnormal ABI versus 0.476 ± 0.124 mmHg/min in patients with normal ABI (P = 0.007). In a logistic regression model the time rate index was associated with ABI, regardless of age (OR = 6.9, 95% CI = 1.1- 42.1; P = 0.04). In a multiple linear regression model, adjusting for age, SBP and diabetes, the time rate index was strongly associated with ABI (P < 0.01). None of the other indexes of BP variability were associated with ABI in univariate and multivariate analyses. Time rate index is a sensible method to measure BP variability by ABPM. Its performance for risk stratification of patients with hypertension should be explored in longitudinal studies.

  10. Association between different measurements of blood pressure variability by ABP monitoring and ankle-brachial index

    Directory of Open Access Journals (Sweden)

    Moreira Leila B

    2010-11-01

    Full Text Available Abstract Background Blood pressure (BP variability has been associated with cardiovascular outcomes, but there is no consensus about the more effective method to measure it by ambulatory blood pressure monitoring (ABPM. We evaluated the association between three different methods to estimate BP variability by ABPM and the ankle brachial index (ABI. Methods and Results In a cross-sectional study of patients with hypertension, BP variability was estimated by the time rate index (the first derivative of SBP over time, standard deviation (SD of 24-hour SBP; and coefficient of variability of 24-hour SBP. ABI was measured with a doppler probe. The sample included 425 patients with a mean age of 57 ± 12 years, being 69.2% women, 26.1% current smokers and 22.1% diabetics. Abnormal ABI (≤ 0.90 or ≥ 1.40 was present in 58 patients. The time rate index was 0.516 ± 0.146 mmHg/min in patients with abnormal ABI versus 0.476 ± 0.124 mmHg/min in patients with normal ABI (P = 0.007. In a logistic regression model the time rate index was associated with ABI, regardless of age (OR = 6.9, 95% CI = 1.1- 42.1; P = 0.04. In a multiple linear regression model, adjusting for age, SBP and diabetes, the time rate index was strongly associated with ABI (P Conclusion Time rate index is a sensible method to measure BP variability by ABPM. Its performance for risk stratification of patients with hypertension should be explored in longitudinal studies.

  11. Chromospheric activity of periodic variable stars (including eclipsing binaries) observed in DR2 LAMOST stellar spectral survey

    Science.gov (United States)

    Zhang, Liyun; Lu, Hongpeng; Han, Xianming L.; Jiang, Linyan; Li, Zhongmu; Zhang, Yong; Hou, Yonghui; Wang, Yuefei; Cao, Zihuang

    2018-05-01

    The LAMOST spectral survey provides a rich databases for studying stellar spectroscopic properties and chromospheric activity. We cross-matched a total of 105,287 periodic variable stars from several photometric surveys and databases (CSS, LINEAR, Kepler, a recently updated eclipsing star catalogue, ASAS, NSVS, some part of SuperWASP survey, variable stars from the Tsinghua University-NAOC Transient Survey, and other objects from some new references) with four million stellar spectra published in the LAMOST data release 2 (DR2). We found 15,955 spectra for 11,469 stars (including 5398 eclipsing binaries). We calculated their equivalent widths (EWs) of their Hα, Hβ, Hγ, Hδ and Caii H lines. Using the Hα line EW, we found 447 spectra with emission above continuum for a total of 316 stars (178 eclipsing binaries). We identified 86 active stars (including 44 eclipsing binaries) with repeated LAMOST spectra. A total of 68 stars (including 34 eclipsing binaries) show chromospheric activity variability. We also found LAMOST spectra of 12 cataclysmic variables, five of which show chromospheric activity variability. We also made photometric follow-up studies of three short period targets (DY CVn, HAT-192-0001481, and LAMOST J164933.24+141255.0) using the Xinglong 60-cm telescope and the SARA 90-cm and 1-m telescopes, and obtained new BVRI CCD light curves. We analyzed these light curves and obtained orbital and starspot parameters. We detected the first flare event with a huge brightness increase of more than about 1.5 magnitudes in R filter in LAMOST J164933.24+141255.0.

  12. The relationship between psychosocial variables and measures of ...

    African Journals Online (AJOL)

    was found to be the most important psychosocial variable in the present study, correlating with several .... It includes eight activities of daily living on which patients have to ..... Effects of aerobic exercise versus stress management treatment in.

  13. Night-to-night arousal variability and interscorer reliability of arousal measurements.

    Science.gov (United States)

    Loredo, J S; Clausen, J L; Ancoli-Israel, S; Dimsdale, J E

    1999-11-01

    Measurement of arousals from sleep is clinically important, however, their definition is not well standardized, and little data exist on reliability. The purpose of this study is to determine factors that affect arousal scoring reliability and night-to-night arousal variability. The night-to-night arousal variability and interscorer reliability was assessed in 20 subjects with and without obstructive sleep apnea undergoing attended polysomnography during two consecutive nights. Five definitions of arousal were studied, assessing duration of electroencephalographic (EEG) frequency changes, increases in electromyographic (EMG) activity and leg movement, association with respiratory events, as well as the American Sleep Disorders Association (ASDA) definition of arousals. NA. NA. NA. Interscorer reliability varied with the definition of arousal and ranged from an Intraclass correlation (ICC) of 0.19 to 0.92. Arousals that included increases in EMG activity or leg movement had the greatest reliability, especially when associated with respiratory events (ICC 0.76 to 0.92). The ASDA arousal definition had high interscorer reliability (ICC 0.84). Reliability was lowest for arousals consisting of EEG changes lasting <3 seconds (ICC 0.19 to 0.37). The within subjects night-to-night arousal variability was low for all arousal definitions In a heterogeneous population, interscorer arousal reliability is enhanced by increases in EMG activity, leg movements, and respiratory events and decreased by short duration EEG arousals. The arousal index night-to-night variability was low for all definitions.

  14. On Association Measures for Continuous Variables and Correction for Chance

    NARCIS (Netherlands)

    Warrens, Matthijs J.

    2015-01-01

    This paper studies correction for chance for association measures for continuous variables. The set of linear transformations of Pearson's product-moment correlation is used as the domain of the correction for chance function. Examples of measures in this set are Tucker's congruence coefficient,

  15. Sequential Measurement of Intermodal Variability in Public Transportation PM2.5 and CO Exposure Concentrations.

    Science.gov (United States)

    Che, W W; Frey, H Christopher; Lau, Alexis K H

    2016-08-16

    A sequential measurement method is demonstrated for quantifying the variability in exposure concentration during public transportation. This method was applied in Hong Kong by measuring PM2.5 and CO concentrations along a route connecting 13 transportation-related microenvironments within 3-4 h. The study design takes into account ventilation, proximity to local sources, area-wide air quality, and meteorological conditions. Portable instruments were compacted into a backpack to facilitate measurement under crowded transportation conditions and to quantify personal exposure by sampling at nose level. The route included stops next to three roadside monitors to enable comparison of fixed site and exposure concentrations. PM2.5 exposure concentrations were correlated with the roadside monitors, despite differences in averaging time, detection method, and sampling location. Although highly correlated in temporal trend, PM2.5 concentrations varied significantly among microenvironments, with mean concentration ratios versus roadside monitor ranging from 0.5 for MTR train to 1.3 for bus terminal. Measured inter-run variability provides insight regarding the sample size needed to discriminate between microenvironments with increased statistical significance. The study results illustrate the utility of sequential measurement of microenvironments and policy-relevant insights for exposure mitigation and management.

  16. Measured spatial variability of beach erosion due to aeolian processes.

    NARCIS (Netherlands)

    de Vries, S.; Verheijen, A.H.; Hoonhout, B.M.; Vos, S.E.; Cohn, Nicholas; Ruggiero, P; Aagaard, T.; Deigaard, R.; Fuhrman, D.

    2017-01-01

    This paper shows the first results of measured spatial variability of beach erosion due to aeolian processes during the recently conducted SEDEX2 field experiment at Long Beach, Washington, U.S.A.. Beach erosion and sedimentation were derived using series of detailed terrestrial LIDAR measurements

  17. Hidden measurements, hidden variables and the volume representation of transition probabilities

    OpenAIRE

    Oliynyk, Todd A.

    2005-01-01

    We construct, for any finite dimension $n$, a new hidden measurement model for quantum mechanics based on representing quantum transition probabilities by the volume of regions in projective Hilbert space. For $n=2$ our model is equivalent to the Aerts sphere model and serves as a generalization of it for dimensions $n \\geq 3$. We also show how to construct a hidden variables scheme based on hidden measurements and we discuss how joint distributions arise in our hidden variables scheme and th...

  18. Determination of continuous variable entanglement by purity measurements.

    Science.gov (United States)

    Adesso, Gerardo; Serafini, Alessio; Illuminati, Fabrizio

    2004-02-27

    We classify the entanglement of two-mode Gaussian states according to their degree of total and partial mixedness. We derive exact bounds that determine maximally and minimally entangled states for fixed global and marginal purities. This characterization allows for an experimentally reliable estimate of continuous variable entanglement based on measurements of purity.

  19. [Comparison of self-reported anthropometric variables and real measurement data].

    Science.gov (United States)

    Díaz-García, J; González-Zapata, L I; Estrada-Restrepo, A

    2012-06-01

    The objectives of this study were to evaluate self-reporting of weight, height, and waist circumference, and to compare that perception with the real measurements in college students of the MESPYN cohort--Medellin, Salud Pública y Nutrición--from the University of Antioquia (UdeA), Colombia. A cross-sectional study was conducted starting with the first measurement of the MESPYN Cohort 2009-2010. The sample included volunteer students from different academic areas. Self-perception of weight, height, and waist circumference were recorded before the real measurements were performed. Intraclass correlation coefficients (ICC) were calculated for all the variables, and an alpha of 0.05 was used. The concordance between real measurements and self-referred values was evaluated with the Bland and Altman method. 424 volunteer students were included. The average real weight (kg) in males was 67.4 +/- 10.4 and self-reported: 67.0 +/- 11.0; in females the real value was 55.7 +/- 10.1 and self-reported: 55.0 +/- 9.0. The average real height (m) in males was 1.73 +/- 6.1 and self-reported: 1.73 +/- 6.0; in females the real value was 1.60 +/- 5.9 and self-reported: 1.61 +/- 6.0. In males, the average real waist circumference (cm) was 76.6 +/- 8.0 and self-reported: 75.0 +/- 14.0; in females the real value was 69.9 +/- 8.0 and self-reported: 70.0 +/- 9.0. Weight ICC: 0.956, 95% CI (0.95; 0.97), (p < 0.01); height ICC: 0.953, 95%IC (0.91; 0.97), (p < 0.01), and waist circumference ICC: 0.593, 95% IC (0.55; 0.65), (p < 0.01). In conclusion, anthropometric nutritional evaluation of UdeA students can be performed with self-reported data for weight and height, but the evaluation of abdominal obesity requires direct measurement of waist circumference.

  20. Some metabolic and anthropometric variables in obes children by measuring serum insulin, and leptin

    International Nuclear Information System (INIS)

    Nour Eldin, A.M.

    2004-01-01

    The present study aimed to assess serum leptin level in obese children to study its correlation with some metabolic variables as serum insulin and serum glucose. The study was conducted on 30 obese children of age from 9-14 years with body mass index (BMI) > 27.8 Kg/m 2 . All children were subjected to history taking, clinical examination, anthropometric measurements and laboratory investigations including fasting serum leptin, insulin and blood glucose. Serum leptin was significantly higher in obese children (102.3± 56.2 ng/ml) compared to non-obese ones (48.15±26.1 ng/ml). The relation between serum leptin and anthropometric measurements and laboratory investigations including fasting serum insulin and blood glucose. Serum leptin was significantly higher in obese children (102.3± 56.2 ng/ml)compared to non-obese ones (48.15±26.1 ng/ml). The relation between serum leptin and anthropometric variables was positively correlated with BMI r s = 0.68, (p s = 0.59.(p<0.01). It is concluded that serum leptin is increased in obesity and its concentration effects the size of the body. Moreover, the relation of leptin and insulin suggests a positive role of leptin in insulin resistance, which are common metabolic disorders associated with obesity

  1. An evaluation of FIA's stand age variable

    Science.gov (United States)

    John D. Shaw

    2015-01-01

    The Forest Inventory and Analysis Database (FIADB) includes a large number of measured and computed variables. The definitions of measured variables are usually well-documented in FIA field and database manuals. Some computed variables, such as live basal area of the condition, are equally straightforward. Other computed variables, such as individual tree volume,...

  2. Performance Measure as Feedback Variable in Image Processing

    Directory of Open Access Journals (Sweden)

    Ristić Danijela

    2006-01-01

    Full Text Available This paper extends the view of image processing performance measure presenting the use of this measure as an actual value in a feedback structure. The idea behind is that the control loop, which is built in that way, drives the actual feedback value to a given set point. Since the performance measure depends explicitly on the application, the inclusion of feedback structures and choice of appropriate feedback variables are presented on example of optical character recognition in industrial application. Metrics for quantification of performance at different image processing levels are discussed. The issues that those metrics should address from both image processing and control point of view are considered. The performance measures of individual processing algorithms that form a character recognition system are determined with respect to the overall system performance.

  3. Novel Variable Structure Measurement System with Intelligent Components for Flight Vehicles

    Directory of Open Access Journals (Sweden)

    Shen Kai

    2017-06-01

    Full Text Available The paper presents a method of developing a variable structure measurement system with intelligent components for flight vehicles. In order to find a distinguishing feature of a variable structure, a numerical criterion for selecting measuring sensors is proposed by quantifying the observability of different states of the system. Based on the Peter K. Anokhin’s theory of functional systems, a mechanism of “action acceptor” is built with intelligent components, e.g. self-organization algorithms. In this mechanism, firstly, prediction models of system states are constructed using self-organization algorithms; secondly, the predicted and measured values are compared; thirdly, an optimal structure of the measurement system is finally determined based on the results of comparison. According to the results of simulation with practical data and experiments obtained during field tests, the novel developed measurement system has the properties of high-accuracy, reliable operation and fault tolerance.

  4. Tethered balloon-based measurements of meteorological variables and aerosols

    Science.gov (United States)

    Sentell, R. J.; Storey, R. W.; Chang, J. J. C.; Jacobsen, S. J.

    1976-01-01

    Tethered balloon based measurements of the vertical distributions of temperature, humidity, wind speed, and aerosol concentrations were taken over a 4-hour period beginning at sunrise on June 29, 1976, at Wallops Island, Virginia. Twelve consecutive profiles of each variable were obtained from ground to about 500 meters. These measurements were in conjuction with a noise propagation study on remotely arrayed acoustic range (ROMAAR) at Wallops Flight Center. An organized listing of these vertical soundings is presented. The tethered balloon system configuration utilized for these measurements is described.

  5. Estimation of road profile variability from measured vehicle responses

    Science.gov (United States)

    Fauriat, W.; Mattrand, C.; Gayton, N.; Beakou, A.; Cembrzynski, T.

    2016-05-01

    When assessing the statistical variability of fatigue loads acting throughout the life of a vehicle, the question of the variability of road roughness naturally arises, as both quantities are strongly related. For car manufacturers, gathering information on the environment in which vehicles evolve is a long and costly but necessary process to adapt their products to durability requirements. In the present paper, a data processing algorithm is proposed in order to estimate the road profiles covered by a given vehicle, from the dynamic responses measured on this vehicle. The algorithm based on Kalman filtering theory aims at solving a so-called inverse problem, in a stochastic framework. It is validated using experimental data obtained from simulations and real measurements. The proposed method is subsequently applied to extract valuable statistical information on road roughness from an existing load characterisation campaign carried out by Renault within one of its markets.

  6. Biogenic carbon in combustible waste: Waste composition, variability and measurement uncertainty

    DEFF Research Database (Denmark)

    Larsen, Anna Warberg; Fuglsang, Karsten; Pedersen, Niels H.

    2013-01-01

    described in the literature. This study addressed the variability of biogenic and fossil carbon in combustible waste received at a municipal solid waste incinerator. Two approaches were compared: (1) radiocarbon dating (14C analysis) of carbon dioxide sampled from the flue gas, and (2) mass and energy......, the measurement uncertainties related to the two approaches were determined. Two flue gas sampling campaigns at a full-scale waste incinerator were included: one during normal operation and one with controlled waste input. Estimation of carbon contents in the main waste types received was included. Both the 14C...... method and the balance method represented promising methods able to provide good quality data for the ratio between biogenic and fossil carbon in waste. The relative uncertainty in the individual experiments was 7–10% (95% confidence interval) for the 14C method and slightly lower for the balance method....

  7. Inter-observer and inter-examination variability of manual vertebral bone attenuation measurements on computed tomography

    International Nuclear Information System (INIS)

    Pompe, Esther; Lammers, Jan-Willem J.; Jong, Pim A. de; Jong, Werner U. de; Takx, Richard A.P.; Eikendal, Anouk L.M.; Willemink, Martin J.; Mohamed Hoesein, Firdaus A.A.; Oudkerk, Matthijs; Budde, Ricardo P.J.

    2016-01-01

    To determine inter-observer and inter-examination variability of manual attenuation measurements of the vertebrae in low-dose unenhanced chest computed tomography (CT). Three hundred and sixty-seven lung cancer screening trial participants who underwent baseline and repeat unenhanced low-dose CT after 3 months because of an indeterminate lung nodule were included. The CT attenuation value of the first lumbar vertebrae (L1) was measured in all CTs by one observer to obtain inter-examination reliability. Six observers performed measurements in 100 randomly selected CTs to determine agreement with limits of agreement and Bland-Altman plots and reliability with intraclass correlation coefficients (ICCs). Reclassification analyses were performed using a threshold of 110 HU to define osteoporosis. Inter-examination reliability was excellent with an ICC of 0.92 (p < 0.001). Inter-examination limits of agreement ranged from -26 to 28 HU with a mean difference of 1 ± 14 HU. Inter-observer reliability ICCs ranged from 0.70 to 0.91. Inter-examination variability led to 11.2 % reclassification of participants and inter-observer variability led to 22.1 % reclassification. Vertebral attenuation values can be manually quantified with good to excellent inter-examination and inter-observer reliability on unenhanced low-dose chest CT. This information is valuable for early detection of osteoporosis on low-dose chest CT. (orig.)

  8. Can Wearable Devices Accurately Measure Heart Rate Variability? A Systematic Review.

    Science.gov (United States)

    Georgiou, Konstantinos; Larentzakis, Andreas V; Khamis, Nehal N; Alsuhaibani, Ghadah I; Alaska, Yasser A; Giallafos, Elias J

    2018-03-01

    A growing number of wearable devices claim to provide accurate, cheap and easily applicable heart rate variability (HRV) indices. This is mainly accomplished by using wearable photoplethysmography (PPG) and/or electrocardiography (ECG), through simple and non-invasive techniques, as a substitute of the gold standard RR interval estimation through electrocardiogram. Although the agreement between pulse rate variability (PRV) and HRV has been evaluated in the literature, the reported results are still inconclusive especially when using wearable devices. The purpose of this systematic review is to investigate if wearable devices provide a reliable and precise measurement of classic HRV parameters in rest as well as during exercise. A search strategy was implemented to retrieve relevant articles from MEDLINE and SCOPUS databases, as well as, through internet search. The 308 articles retrieved were reviewed for further evaluation according to the predetermined inclusion/exclusion criteria. Eighteen studies were included. Sixteen of them integrated ECG - HRV technology and two of them PPG - PRV technology. All of them examined wearable devices accuracy in RV detection during rest, while only eight of them during exercise. The correlation between classic ECG derived HRV and the wearable RV ranged from very good to excellent during rest, yet it declined progressively as exercise level increased. Wearable devices may provide a promising alternative solution for measuring RV. However, more robust studies in non-stationary conditions are needed using appropriate methodology in terms of number of subjects involved, acquisition and analysis techniques implied.

  9. Continuous performance task in ADHD: Is reaction time variability a key measure?

    Science.gov (United States)

    Levy, Florence; Pipingas, Andrew; Harris, Elizabeth V; Farrow, Maree; Silberstein, Richard B

    2018-01-01

    To compare the use of the Continuous Performance Task (CPT) reaction time variability (intraindividual variability or standard deviation of reaction time), as a measure of vigilance in attention-deficit hyperactivity disorder (ADHD), and stimulant medication response, utilizing a simple CPT X-task vs an A-X-task. Comparative analyses of two separate X-task vs A-X-task data sets, and subgroup analyses of performance on and off medication were conducted. The CPT X-task reaction time variability had a direct relationship to ADHD clinician severity ratings, unlike the CPT A-X-task. Variability in X-task performance was reduced by medication compared with the children's unmedicated performance, but this effect did not reach significance. When the coefficient of variation was applied, severity measures and medication response were significant for the X-task, but not for the A-X-task. The CPT-X-task is a useful clinical screening test for ADHD and medication response. In particular, reaction time variability is related to default mode interference. The A-X-task is less useful in this regard.

  10. Computed tomography dose and variability of airway dimension measurements: how low can we go?

    International Nuclear Information System (INIS)

    Jong, Pim A. de; Long, Frederick R.; Nakano, Yasutaka

    2006-01-01

    Quantitative CT shows promise as an outcome measure for cystic fibrosis (CF) lung disease in infancy, but must be accomplished at a dose as low as reasonably achievable. To determine the feasibility of ultra-low-dose CT for quantitative measurements of airway dimensions. Two juvenile pigs were anesthetized and their lungs scanned at 25 cm H 2 O face-mask pressure in apnoea using beam currents of 5, 10, 20, 40 and 100 mAs. The lumen diameters and wall thicknesses of matched airways (n=22) at each dose were measured by two observers using validated software. Measurement variability at each dose was compared to that at 100 mAs (reference dose) for large and small airways (lumen diameter <2.5 mm). Lowering CT dose (mAs) affected measurement variability for lumen diameter of small and large airways (P<0.001) and for wall thickness of small (P<0.001), but not large (P=0.63), airways. To obtain the same measurement variability at 5 mAs as at 100 mAs, four to six small airways or one to three large airways have to be measured and averaged. Quantitative airway measurements are feasible on images obtained at as low as 5 mAs, but more airways need to be measured to compensate for greater measurement variability. (orig.)

  11. Environmental economic variables - what has been measured until now?

    International Nuclear Information System (INIS)

    Ahlroth, S.; Palm, V.

    2001-01-01

    Environmental accounting encompasses a variety of economic variables. They range from production values of different branches of industry, through fiscal instruments such as environmental taxes, and to valuation studies of external effects of the economy. This paper tries to map out the different aspects of variables, and to point out their linkages and uses, viewed from an environmental accounting perspective. Also, the estimated size of the different types of variables is discussed, based mainly on Swedish studies and on a national scale. Included variables are GDP, export and import, environmental taxes, subsidies, environmental costs, remediation costs, environmental damage costs and examples of prevention costs. We will divide the economic variables into four different types: 1. Those that are recorded as the actors payment on the market 2. Those that are part of the government budget 3. Those that serve as a valuation of the costs incurred on society 4. Those that could be invested to prevent environmental damage The size of the different costs will be taken from a variety of studies, mainly Swedish, and be put in relation to GDP or similar. A brief discussion of the Swedish situation as compared to international figures will also be made

  12. Interobserver Variability of Ki-67 Measurement in Breast Cancer

    Directory of Open Access Journals (Sweden)

    Yul Ri Chung

    2016-03-01

    Full Text Available Background: As measurement of Ki-67 proliferation index is an important part of breast cancer diagnostics, we conducted a multicenter study to examine the degree of concordance in Ki-67 counting and to find factors that lead to its variability. Methods: Thirty observers from thirty different institutions reviewed Ki-67–stained slides of 20 different breast cancers on whole sections and tissue microarray (TMA by online system. Ten of the 20 breast cancers had hot spots of Ki-67 expression. Each observer scored Ki-67 in two different ways: direct counting (average vs. hot spot method and categorical estimation. Intraclass correlation coefficient (ICC of Ki-67 index was calculated for comparative analysis. Results: For direct counting, ICC of TMA was slightly higher than that of whole sections using average method (0.895 vs 0.858. The ICC of tumors with hot spots was lower than that of tumors without (0.736 vs 0.874. In tumors with hot spots, observers took an additional counting from the hot spot; the ICC of whole sections using hot spot method was still lower than that of TMA (0.737 vs 0.895. In categorical estimation, Ki-67 index showed a wide distribution in some cases. Nevertheless, in tumors with hot spots, the range of distribution in Ki-67 categories was decreased with hot spot method and in TMA platform. Conclusions: Interobserver variability of Ki-67 index for direct counting and categorical estimation was relatively high. Tumors with hot spots showed greater interobserver variability as opposed to those without, and restricting the measurement area yielded lower interobserver variability.

  13. Biogenic carbon in combustible waste: waste composition, variability and measurement uncertainty.

    Science.gov (United States)

    Larsen, Anna W; Fuglsang, Karsten; Pedersen, Niels H; Fellner, Johann; Rechberger, Helmut; Astrup, Thomas

    2013-10-01

    Obtaining accurate data for the contents of biogenic and fossil carbon in thermally-treated waste is essential for determination of the environmental profile of waste technologies. Relations between the variability of waste chemistry and the biogenic and fossil carbon emissions are not well described in the literature. This study addressed the variability of biogenic and fossil carbon in combustible waste received at a municipal solid waste incinerator. Two approaches were compared: (1) radiocarbon dating ((14)C analysis) of carbon dioxide sampled from the flue gas, and (2) mass and energy balance calculations using the balance method. The ability of the two approaches to accurately describe short-term day-to-day variations in carbon emissions, and to which extent these short-term variations could be explained by controlled changes in waste input composition, was evaluated. Finally, the measurement uncertainties related to the two approaches were determined. Two flue gas sampling campaigns at a full-scale waste incinerator were included: one during normal operation and one with controlled waste input. Estimation of carbon contents in the main waste types received was included. Both the (14)C method and the balance method represented promising methods able to provide good quality data for the ratio between biogenic and fossil carbon in waste. The relative uncertainty in the individual experiments was 7-10% (95% confidence interval) for the (14)C method and slightly lower for the balance method.

  14. Fuzzy central tendency measure for time series variability analysis with application to fatigue electromyography signals.

    Science.gov (United States)

    Xie, Hong-Bo; Dokos, Socrates

    2013-01-01

    A new method, namely fuzzy central tendency measure (fCTM) analysis, that could enable measurement of the variability of a time series, is presented in this study. Tests on simulated data sets show that fCTM is superior to the conventional central tendency measure (CTM) in several respects, including improved relative consistency and robustness to noise. The proposed fCTM method was applied to electromyograph (EMG) signals recorded during sustained isometric contraction for tracking local muscle fatigue. The results showed that the fCTM increased significantly during the development of muscle fatigue, and it was more sensitive to the fatigue phenomenon than mean frequency (MNF), the most commonly-used muscle fatigue indicator.

  15. Bayesian modeling of measurement error in predictor variables using item response theory

    NARCIS (Netherlands)

    Fox, Gerardus J.A.; Glas, Cornelis A.W.

    2000-01-01

    This paper focuses on handling measurement error in predictor variables using item response theory (IRT). Measurement error is of great important in assessment of theoretical constructs, such as intelligence or the school climate. Measurement error is modeled by treating the predictors as unobserved

  16. Spatial Variability of Soil-Water Storage in the Southern Sierra Critical Zone Observatory: Measurement and Prediction

    Science.gov (United States)

    Oroza, C.; Bales, R. C.; Zheng, Z.; Glaser, S. D.

    2017-12-01

    Predicting the spatial distribution of soil moisture in mountain environments is confounded by multiple factors, including complex topography, spatial variably of soil texture, sub-surface flow paths, and snow-soil interactions. While remote-sensing tools such as passive-microwave monitoring can measure spatial variability of soil moisture, they only capture near-surface soil layers. Large-scale sensor networks are increasingly providing soil-moisture measurements at high temporal resolution across a broader range of depths than are accessible from remote sensing. It may be possible to combine these in-situ measurements with high-resolution LIDAR topography and canopy cover to estimate the spatial distribution of soil moisture at high spatial resolution at multiple depths. We study the feasibility of this approach using six years (2009-2014) of daily volumetric water content measurements at 10-, 30-, and 60-cm depths from the Southern Sierra Critical Zone Observatory. A non-parametric, multivariate regression algorithm, Random Forest, was used to predict the spatial distribution of depth-integrated soil-water storage, based on the in-situ measurements and a combination of node attributes (topographic wetness, northness, elevation, soil texture, and location with respect to canopy cover). We observe predictable patterns of predictor accuracy and independent variable ranking during the six-year study period. Predictor accuracy is highest during the snow-cover and early recession periods but declines during the dry period. Soil texture has consistently high feature importance. Other landscape attributes exhibit seasonal trends: northness peaks during the wet-up period, and elevation and topographic-wetness index peak during the recession and dry period, respectively.

  17. Inter-observer variability in fetal biometric measurements.

    Science.gov (United States)

    Kilani, Rami; Aleyadeh, Wesam; Atieleh, Luay Abu; Al Suleimat, Abdul Mane; Khadra, Maysa; Hawamdeh, Hassan M

    2018-02-01

    To evaluate inter-observer variability and reproducibility of ultrasound measurements for fetal biometric parameters. A prospective cohort study was implemented in two tertiary care hospitals in Amman, Jordan; Prince Hamza Hospital and Albashir Hospital. 192 women with a singleton pregnancy at a gestational age of 18-36 weeks were the participants in the study. Transabdominal scans for fetal biometric parameter measurement were performed on study participants from the period of November 2014 to March 2015. Women who agreed to participate in the study were administered two ultrasound scans for head circumference, abdominal circumference and femur length. The correlation coefficient was calculated. Bland-Altman plots were used to analyze the degree of measurement agreement between observers. Limits of agreement ± 2 SD for the differences in fetal biometry measurements in proportions of the mean of the measurements were derived. Main outcome measures examine the reproducibility of fetal biometric measurements by different observers. High inter-observer inter-class correlation coefficient (ICC) was found for femur length (0.990) and abdominal circumference (0.996) where Bland-Altman plots showed high degrees of agreement. The highest degrees of agreement were noted in the measurement of abdominal circumference followed by head circumference. The lowest degree of agreement was found for femur length measurement. We used a paired-sample t-test and found that the mean difference between duplicate measurements was not significant (P > 0.05). Biometric fetal parameter measurements may be reproducible by different operators in the clinical setting with similar results. Fetal head circumference, abdominal circumference and femur length were highly reproducible. Large organized studies are needed to ensure accurate fetal measurements due to the important clinical implications of inaccurate measurements. Copyright © 2018. Published by Elsevier B.V.

  18. Variability in Measured Space Temperatures in 60 Homes

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, D.; Lay, K.

    2013-03-01

    This report discusses the observed variability in indoor space temperature in a set of 60 homes located in Florida, New York, Oregon, and Washington. Temperature data were collected at 15-minute intervals for an entire year, including living room, master bedroom, and outdoor air temperature (Arena, et. al). The data were examined to establish the average living room temperature for the set of homes for the heating and cooling seasons, the variability of living room temperature depending on climate, and the variability of indoor space temperature within the homes. The accuracy of software-based energy analysis depends on the accuracy of input values. Thermostat set point is one of the most influential inputs for building energy simulation. Several industry standards exist that recommend differing default thermostat settings for heating and cooling seasons. These standards were compared to the values calculated for this analysis. The data examined for this report show that there is a definite difference between the climates and that the data do not agree well with any particular standard.

  19. Bias correction by use of errors-in-variables regression models in studies with K-X-ray fluorescence bone lead measurements.

    Science.gov (United States)

    Lamadrid-Figueroa, Héctor; Téllez-Rojo, Martha M; Angeles, Gustavo; Hernández-Ávila, Mauricio; Hu, Howard

    2011-01-01

    In-vivo measurement of bone lead by means of K-X-ray fluorescence (KXRF) is the preferred biological marker of chronic exposure to lead. Unfortunately, considerable measurement error associated with KXRF estimations can introduce bias in estimates of the effect of bone lead when this variable is included as the exposure in a regression model. Estimates of uncertainty reported by the KXRF instrument reflect the variance of the measurement error and, although they can be used to correct the measurement error bias, they are seldom used in epidemiological statistical analyzes. Errors-in-variables regression (EIV) allows for correction of bias caused by measurement error in predictor variables, based on the knowledge of the reliability of such variables. The authors propose a way to obtain reliability coefficients for bone lead measurements from uncertainty data reported by the KXRF instrument and compare, by the use of Monte Carlo simulations, results obtained using EIV regression models vs. those obtained by the standard procedures. Results of the simulations show that Ordinary Least Square (OLS) regression models provide severely biased estimates of effect, and that EIV provides nearly unbiased estimates. Although EIV effect estimates are more imprecise, their mean squared error is much smaller than that of OLS estimates. In conclusion, EIV is a better alternative than OLS to estimate the effect of bone lead when measured by KXRF. Copyright © 2010 Elsevier Inc. All rights reserved.

  20. Contribution to the discussion of P.M. Fayers and David J. Hand: Causal variables, indicator variables and measurement scales: an example from quality of life

    DEFF Research Database (Denmark)

    Keiding, Niels

    2002-01-01

    Causal variables; Clinimetric scales; Composite scales; Construct validity; Measurement scales; Multi-item scales; Quality-of-life instruments......Causal variables; Clinimetric scales; Composite scales; Construct validity; Measurement scales; Multi-item scales; Quality-of-life instruments...

  1. Variability of ferritin measurements in chronic kidney disease; implications for iron management.

    Science.gov (United States)

    Ford, Bradley A; Coyne, Daniel W; Eby, Charles S; Scott, Mitchell G

    2009-01-01

    Serum ferritin levels are a proxy measure of iron stores; and existing guidelines for managing anemia in hemodialysis patients suggest that serum ferritin concentrations should be maintained at >200 ng/ml. The KDOQI recommendations further state there is insufficient evidence advocating routine intravenous iron when ferritin levels exceed 500 ng/ml. Here we determined the interassay differences and short-term intraindividual variability of serum ferritin measurements in patients on chronic hemodialysis to illustrate how these variances may affect treatment decisions. Intermethod variations of up to 150 ng/ml were found comparing six commonly used ferritin assays that evaluated thirteen pools of serum from hemodialysis and nonhemodialysis patients. The intraindividual variability for ferritin in 60 stable hemodialysis patients ranged between 2-62% measured over an initial two-week period and from 3-52% when factored over a six-week period. Our results suggests that single serum ferritin values should not be used to guide clinical decisions regarding treatment of chronic hemodialysis patients with intravenous iron due to significant analytical and intraindividual variability.

  2. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    NARCIS (Netherlands)

    E.M.M. Santos (Emilie M.); A.J. Yoo (Albert J.); L.F.M. Beenen (Ludo); O.A. Berkhemer (Olvert); M.D. Den Blanken (Mark D.); C. Wismans (Carrie); W.J. Niessen (Wiro); C.B. Majoie (Charles); H. Marquering (Henk)

    2016-01-01

    textabstractIntroduction: Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by

  3. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    NARCIS (Netherlands)

    Santos, Emilie M. M.; Yoo, Albert J.; Beenen, Ludo F.; Berkhemer, Olvert A.; den Blanken, Mark D.; Wismans, Carrie; Niessen, Wiro J.; Majoie, Charles B.; Marquering, Henk A.; Fransen, Puck S. S.; Beumer, Debbie; van den Berg, Lucie A.; Lingsma, Hester F.; Schonewille, Wouter J.; Vos, Jan Albert; Nederkoorn, Paul J.; Wermer, Marieke J. H.; van Walderveen, Marianne A. A.; Staals, Julie; Hofmeijer, Jeannette; van Oostayen, Jacques A.; Lycklama à Nijeholt, Geert J.; Boiten, Jelis; Brouwer, Patrick A.; Emmer, Bart J.; de Bruijn, Sebastiaan F.; van Dijk, Lukas C.; Kappelle, L. Jaap; Lo, Rob H.; van Dijk, Ewoud J.; de Vries, Joost; de Kort, Paul L. M.; van den Berg, Jan S. P.; A A M van Hasselt, Boudewijn; Aerden, Leo A. M.; Dallinga, René J.; Visser, Marieke C.; Bot, Joseph C. J.; Vroomen, Patrick C.; Eshghi, Omid; Schreuder, Tobien H. C. M. L.; Heijboer, Roel J. J.; Keizer, Koos; Tielbeek, Alexander V.; Hertog, Heleen M. Den; Gerrits, Dick G.; van den Berg-Vos, Renske M.; Karas, Giorgos B.; Steyerberg, Ewout W.; Flach, H. Zwenneke; Sprengers, Marieke E. S.; Jenniskens, Sjoerd F. M.; van den Berg, René; Koudstaal, Peter J.; van Zwam, Wim H.; Roos, Yvo B. W. E. M.; van der Lugt, Aad; van Oostenbrugge, Robert J.; Dippel, Diederik W. J.

    2016-01-01

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert

  4. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    NARCIS (Netherlands)

    Santos, E.M.; Yoo, A.J.; Beenen, L.F.; Berkhemer, O.A.; Blanken, M.D. den; Wismans, C.; Niessen, W.J.; Majoie, C.B.; Marquering, H.A.; Dijk, E.J. van; et al.,

    2016-01-01

    INTRODUCTION: Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and

  5. THE RELIABILITY AND ACCURACY OF THE TRIPLE MEASUREMENTS OF ANALOG PROCESS VARIABLES

    Directory of Open Access Journals (Sweden)

    V. A. Anishchenko

    2017-01-01

    Full Text Available The increase in unit capacity of electric equipment as well as complication of technological processes, devices control and management of the latter in power plants and substations demonstrate the need to improve the reliability and accuracy of measurement information characterizing the state of the objects being managed. The mentioned objective is particularly important for nuclear power plants, where the price of inaccuracy of measurement responsible process variables is particularly high and the error might lead to irreparable consequences. Improving the reliability and accuracy of measurements along with the improvement of the element base is provided by methods of operational validation. These methods are based on the use of information redundancy (structural, topological, temporal. In particular, information redundancy can be achieved by the simultaneous measurement of one analog variable by two (duplication or three devices (triplication i.e., triple redundancy. The problem of operational control of the triple redundant system of measurement of electrical analog variables (currents, voltages, active and reactive power and energy is considered as a special case of signal processing by an orderly sampling on the basis of majority transformation and transformation being close to majority one. Difficulties in monitoring the reliability of measurements are associated with the two tasks. First, one needs to justify the degree of truncation of the distributions of random errors of measurements and allowable residuals of the pairwise differences of the measurement results. The second task consists in formation of the algorithm of joint processing of a set of separate measurements determined as valid. The quality of control is characterized by the reliability, which adopted the synonym of validity, and accuracy of the measuring system. Taken separately, these indicators might lead to opposite results. A compromise solution is therefore proposed

  6. Spatial modelling of marine organisms in Forsmark and Oskarshamn. Including calculation of physical predictor variables

    Energy Technology Data Exchange (ETDEWEB)

    Carlen, Ida; Nikolopoulos, Anna; Isaeus, Martin (AquaBiota Water Research, Stockholm (SE))

    2007-06-15

    GIS grids (maps) of marine parameters were created using point data from previous site investigations in the Forsmark and Oskarshamn areas. The proportion of global radiation reaching the sea bottom in Forsmark and Oskarshamn was calculated in ArcView, using Secchi depth measurements and the digital elevation models for the respective area. The number of days per year when the incoming light exceeds 5 MJ/m2 at the bottom was then calculated using the result of the previous calculations together with measured global radiation. Existing modelled grid-point data on bottom and pelagic temperature for Forsmark were interpolated to create surface covering grids. Bottom and pelagic temperature grids for Oskarshamn were calculated using point measurements to achieve yearly averages for a few points and then using regressions with existing grids to create new maps. Phytoplankton primary production in Forsmark was calculated using point measurements of chlorophyll and irradiance, and a regression with a modelled grid of Secchi depth. Distribution of biomass of macrophyte communities in Forsmark and Oskarshamn was calculated using spatial modelling in GRASP, based on field data from previous surveys. Physical parameters such as those described above were used as predictor variables. Distribution of biomass of different functional groups of fish in Forsmark was calculated using spatial modelling based on previous surveys and with predictor variables such as physical parameters and results from macrophyte modelling. All results are presented as maps in the report. The quality of the modelled predictions varies as a consequence of the quality and amount of the input data, the ecology and knowledge of the predicted phenomena, and by the modelling technique used. A substantial part of the variation is not described by the models, which should be expected for biological modelling. Therefore, the resulting grids should be used with caution and with this uncertainty kept in mind. All

  7. Spatial modelling of marine organisms in Forsmark and Oskarshamn. Including calculation of physical predictor variables

    International Nuclear Information System (INIS)

    Carlen, Ida; Nikolopoulos, Anna; Isaeus, Martin

    2007-06-01

    GIS grids (maps) of marine parameters were created using point data from previous site investigations in the Forsmark and Oskarshamn areas. The proportion of global radiation reaching the sea bottom in Forsmark and Oskarshamn was calculated in ArcView, using Secchi depth measurements and the digital elevation models for the respective area. The number of days per year when the incoming light exceeds 5 MJ/m2 at the bottom was then calculated using the result of the previous calculations together with measured global radiation. Existing modelled grid-point data on bottom and pelagic temperature for Forsmark were interpolated to create surface covering grids. Bottom and pelagic temperature grids for Oskarshamn were calculated using point measurements to achieve yearly averages for a few points and then using regressions with existing grids to create new maps. Phytoplankton primary production in Forsmark was calculated using point measurements of chlorophyll and irradiance, and a regression with a modelled grid of Secchi depth. Distribution of biomass of macrophyte communities in Forsmark and Oskarshamn was calculated using spatial modelling in GRASP, based on field data from previous surveys. Physical parameters such as those described above were used as predictor variables. Distribution of biomass of different functional groups of fish in Forsmark was calculated using spatial modelling based on previous surveys and with predictor variables such as physical parameters and results from macrophyte modelling. All results are presented as maps in the report. The quality of the modelled predictions varies as a consequence of the quality and amount of the input data, the ecology and knowledge of the predicted phenomena, and by the modelling technique used. A substantial part of the variation is not described by the models, which should be expected for biological modelling. Therefore, the resulting grids should be used with caution and with this uncertainty kept in mind. All

  8. Minimizing variability of cascade impaction measurements in inhalers and nebulizers.

    Science.gov (United States)

    Bonam, Matthew; Christopher, David; Cipolla, David; Donovan, Brent; Goodwin, David; Holmes, Susan; Lyapustina, Svetlana; Mitchell, Jolyon; Nichols, Steve; Pettersson, Gunilla; Quale, Chris; Rao, Nagaraja; Singh, Dilraj; Tougas, Terrence; Van Oort, Mike; Walther, Bernd; Wyka, Bruce

    2008-01-01

    The purpose of this article is to catalogue in a systematic way the available information about factors that may influence the outcome and variability of cascade impactor (CI) measurements of pharmaceutical aerosols for inhalation, such as those obtained from metered dose inhalers (MDIs), dry powder inhalers (DPIs) or products for nebulization; and to suggest ways to minimize the influence of such factors. To accomplish this task, the authors constructed a cause-and-effect Ishikawa diagram for a CI measurement and considered the influence of each root cause based on industry experience and thorough literature review. The results illustrate the intricate network of underlying causes of CI variability, with the potential for several multi-way statistical interactions. It was also found that significantly more quantitative information exists about impactor-related causes than about operator-derived influences, the contribution of drug assay methodology and product-related causes, suggesting a need for further research in those areas. The understanding and awareness of all these factors should aid in the development of optimized CI methods and appropriate quality control measures for aerodynamic particle size distribution (APSD) of pharmaceutical aerosols, in line with the current regulatory initiatives involving quality-by-design (QbD).

  9. Outpatient versus inpatient mixed meal tolerance and arginine stimulation testing yields comparable measures of variability for assessment of beta cell function

    Directory of Open Access Journals (Sweden)

    Sudha S. Shankar

    2018-06-01

    Full Text Available Standard practice to minimize variability in beta cell function (BCF measurement is to test in inpatient (IP settings. IP testing strains trial subjects, investigators, and budgets. Outpatient (OP testing may be a solution although there are few reports on OP BCF testing variability. We compared variability metrics between OP and IP from a standardized mixed meal tolerance test (MMTT and arginine stimulation test (AST in two separate type 2 diabetes (T2DM cohorts (OP, n = 20; IP n = 22 in test-retest design. MMTT variables included: insulin sensitivity (Si; beta cell responsivity (Φtot; and disposition index (DItot = Si* Φtot following 470 kCal meal. AST variables included: acute insulin response to arginine (AIRarg and during hyperglycemia (AIRargMAX. Results: Baseline characteristics were well-matched. Between and within subject variance for each parameter across cohorts, and intraclass correlation coefficients (ICC-a measure of reproducibility across parameters were generally comparable for OP to IP. Table summarizes the ICC results for each key parameter and cohort.Test/ParameterOutpatient (95% CIInpatient (95% CIMMTT: Si0.49(0,0.690.28(0,0.60MMTT: Φtot0.65(0.16,0.890.81(0.44,0.93MMTT: DI0.67(0,0.830.36(0,0.69AST: AIR Arg0.96(0.88,0.980.84(0.59,0.94AST: AIR Arg Max0.97(0.90,0.990.95(0.86,0.97AST: ISR0.93(0.77,0.970.93(0.82,0.96In conclusion, the variability (reproducibility of BCF measures from standardized MMTT and AST is comparable between OP and IP settings. These observations have significant implications for complexity and cost of metabolic studies.

  10. Context matters! sources of variability in weekend physical activity among families: a repeated measures study

    Directory of Open Access Journals (Sweden)

    Robert J. Noonan

    2017-04-01

    Full Text Available Abstract Background Family involvement is an essential component of effective physical activity (PA interventions in children. However, little is known about the PA levels and characteristics of PA among families. This study used a repeated measures design and multiple data sources to explore the variability and characteristics of weekend PA among families. Methods Families (including a ‘target’ child aged 9–11 years, their primary caregiver(s and siblings aged 6–8 years were recruited through primary schools in Liverpool, UK. Participants completed a paper-based PA diary and wore an ActiGraph GT9X accelerometer on their left wrist for up to 16 weekend days. ActiGraph.csv files were analysed using the R-package GGIR version 1.1–4. Mean minutes of moderate-to-vigorous PA (MVPA for each weekend of measurement were calculated using linear mixed models, and variance components were estimated for participant (inter-individual, weekend of measurement, and residual error (intra-individual. Intraclass correlation coefficients (ICC were calculated from the proportion of total variance accounted for by inter-individual sources, and used as a measure of reliability. Diary responses were summed to produce frequency counts. To offer contextual insight into weekend PA among family units, demographic, accelerometer, and diary data were combined to form two case studies representative of low and high active families. Results Twenty-five participants from 7 families participated, including 7 ‘target’ children (mean age 9.3 ± 1.1 years, 4 boys, 6 siblings (mean age 7.2 ± 0.7 years; 4 boys and 12 adults (7 mothers and 5 fathers. There was a high degree of variability in target children’s (ICC = 0.55, siblings (ICC = 0.38, and mothers’ MVPA (ICC = 0.58, but not in fathers’ MVPA (ICC = 0.83. Children’s weekend PA was mostly unstructured in nature and undertaken with friends, whereas a greater proportion of parents’ weekend

  11. Posterior variability of inclusion shape based on tomographic measurement data

    International Nuclear Information System (INIS)

    Watzenig, Daniel; Fox, Colin

    2008-01-01

    We treat the problem of recovering the unknown shape of a single inclusion with unknown constant permittivity in an otherwise uniform background material, from uncertain measurements of trans-capacitance at electrodes outside the material. The ubiquitous presence of measurement noise implies that the practical measurement process is probabilistic, and the inverse problem is naturally stated as statistical inference. Formulating the inverse problem in a Bayesian inferential framework requires accurately modelling the forward map, measurement noise, and specifying a prior distribution for the cross-sectional material distribution. Numerical implementation of the forward map is via the boundary element method (BEM) taking advantage of a piecewise constant representation. Summary statistics are calculated using MCMC sampling to characterize posterior variability for synthetic and measured data sets.

  12. Environmental variables measured at multiple spatial scales exert uneven influence on fish assemblages of floodplain lakes

    Science.gov (United States)

    Dembkowski, Daniel J.; Miranda, Leandro E.

    2014-01-01

    We examined the interaction between environmental variables measured at three different scales (i.e., landscape, lake, and in-lake) and fish assemblage descriptors across a range of over 50 floodplain lakes in the Mississippi Alluvial Valley of Mississippi and Arkansas. Our goal was to identify important local- and landscape-level determinants of fish assemblage structure. Relationships between fish assemblage structure and variables measured at broader scales (i.e., landscape-level and lake-level) were hypothesized to be stronger than relationships with variables measured at finer scales (i.e., in-lake variables). Results suggest that fish assemblage structure in floodplain lakes was influenced by variables operating on three different scales. However, and contrary to expectations, canonical correlations between in-lake environmental characteristics and fish assemblage structure were generally stronger than correlations between landscape-level and lake-level variables and fish assemblage structure, suggesting a hierarchy of influence. From a resource management perspective, our study suggests that landscape-level and lake-level variables may be manipulated for conservation or restoration purposes, and in-lake variables and fish assemblage structure may be used to monitor the success of such efforts.

  13. Force measuring valve assemblies, systems including such valve assemblies and related methods

    Science.gov (United States)

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  14. A protocol for measuring spatial variables in soft-sediment tide pools

    Directory of Open Access Journals (Sweden)

    Marina R. Brenha-Nunes

    2016-01-01

    Full Text Available ABSTRACT We present a protocol for measuring spatial variables in large (>50 m2 soft-sediment tide pool. Secondarily, we present the fish capture efficiency of a sampling protocol that based on such spatial variables to calculate relative abundances. The area of the pool is estimated by summing areas of basic geometric forms; the depth, by taken representative measurements of the depth variability of each pool's sector, previously determined according to its perimeter; and the volume, by considering the pool as a prism. These procedures were a trade-off between the acquisition of reliable estimates and the minimization of both the cost of operating and the time spent in field. The fish sampling protocol is based on two con secutive stages: 1 two people search for fishes under structures (e.g., rocks and litters on the pool and capture them with hand seines; 2 these structures are removed and then a beach-seine is hauled over the whole pool. Our method is cheaper than others and fast to operate considering the time in low tides. The method to sample fish is quite efficient resulting in a capture efficiency of 89%.

  15. Virtual continuity of the measurable functions of several variables, and Sobolev embedding theorems

    OpenAIRE

    Vershik, Anatoly; Zatitskiy, Pavel; Petrov, Fedor

    2013-01-01

    Classical Luzin's theorem states that the measurable function of one variable is "almost" continuous. This is not so anymore for functions of several variables. The search of right analogue of the Luzin theorem leads to a notion of virtually continuous functions of several variables. This probably new notion appears implicitly in the statements like embeddings theorems and traces theorems for Sobolev spaces. In fact, it reveals their nature as theorems about virtual continuity. This notion is...

  16. Optimization of Drilling Resistance Measurement (DRM) user-controlled variables

    OpenAIRE

    Tudor, Dumitrescu; Pesce, Giovanni; Ball, Richard

    2017-01-01

    Drilling Resistance Measurement (DRM) is recognised as an important on-site micro-invasive procedure for assessment of construction materials. This paper presents a detailed investigation of user-controlled variables and their influence on drilling resistance. The study proves that the ratio of penetration rate/rotational speed (PR/RPM) is proportional to drilling resistance. Data from Bath stone and an artificial reference stone demonstrates how different materials can be compared using thei...

  17. On the choice of retrieval variables in the inversion of remotely sensed atmospheric measurements.

    Science.gov (United States)

    Ridolfi, Marco; Sgheri, Luca

    2013-05-06

    In this paper we introduce new variables that can be used to retrieve the atmospheric continuum emission in the inversion of remote sensing measurements. This modification tackles the so-called sloppy model problem. We test this approach on an extensive set of real measurements from the Michelson Interferometer for Passive Atmospheric Sounding. The newly introduced variables permit to achieve a more stable inversion and a smaller value of the minimum of the cost function.

  18. Heart rate variability measured early in patients with evolving acute coronary syndrome and 1-year outcomes of rehospitalization and mortality.

    Science.gov (United States)

    Harris, Patricia R E; Stein, Phyllis K; Fung, Gordon L; Drew, Barbara J

    2014-01-01

    This study sought to examine the prognostic value of heart rate variability (HRV) measurement initiated immediately after emergency department presentation for patients with acute coronary syndrome (ACS). Altered HRV has been associated with adverse outcomes in heart disease, but the value of HRV measured during the earliest phases of ACS related to risk of 1-year rehospitalization and death has not been established. Twenty-four-hour Holter recordings of 279 patients with ACS were initiated within 45 minutes of emergency department arrival; recordings with ≥18 hours of sinus rhythm were selected for HRV analysis (number [N] =193). Time domain, frequency domain, and nonlinear HRV were examined. Survival analysis was performed. During the 1-year follow-up, 94 patients were event-free, 82 were readmitted, and 17 died. HRV was altered in relation to outcomes. Predictors of rehospitalization included increased normalized high frequency power, decreased normalized low frequency power, and decreased low/high frequency ratio. Normalized high frequency >42 ms(2) predicted rehospitalization while controlling for clinical variables (hazard ratio [HR] =2.3; 95% confidence interval [CI] =1.4-3.8, P=0.001). Variables significantly associated with death included natural logs of total power and ultra low frequency power. A model with ultra low frequency power 0.3 ng/mL (HR =4.0; 95% CI =1.3-12.1; P=0.016) revealed that each contributed independently in predicting mortality. Nonlinear HRV variables were significant predictors of both outcomes. HRV measured close to the ACS onset may assist in risk stratification. HRV cut-points may provide additional, incremental prognostic information to established assessment guidelines, and may be worthy of additional study.

  19. Quantifying Variability and Correlation in Biomarker and Mineralogical Measurements: Lessons from Five Astrobiological Mars Analogue Expeditions in Iceland

    Science.gov (United States)

    Gentry, D.; Amador, E. S.; Cable, M. L.; Cantrell, T.; Chaudry, N.; Duca, Z. A.; Jacobsen, M. B.; Kirby, J.; McCaig, H. C.; Murukesan, G.; Rader, E.; Cullen, T.; Rennie, V.; Schwieterman, E. W.; Stevens, A. H.; Sutton, S. A.; Tan, G.; Yin, C.; Cullen, D.; Geppert, W.; Stockton, A. M.

    2017-12-01

    Studies in planetary analogue sites correlating remote imagery, mineralogy, and biomarker assay results help predict biomarker distribution and preservation. The FELDSPAR team has conducted five expeditions (2012-2017) to Icelandic Mars analogue sites with an increasingly refined battery of physicochemical measurements and biomarker assays. Two additional expeditions are planned; here we report intermediate results.The biomarker assays performed represent a diversity of potential biomarker types: ATP, cell counts, qPCR with domain-level primers, and DNA content. Mineralogical, chemical, and physical measurements and observations include temperature, pH, moisture content, and Raman, near-IR reflectance, and X-ray fluorescence spectra. Sites are geologically recent basaltic lava flows (Fimmvörðuháls, Eldfell, Holuhraun) and barren basaltic sand plains (Mælifellssandur, Dyngjusandur). All samples were 'homogeneous' at the 1 m to 1 km scale in apparent color, morphology, and grain size.[1]Sample locations were arranged in hierarchically nested grids at 10 cm, 1 m, 10 m, 100 m, and >1 km scales. Several measures of spatial distribution and variability were derived: unbiased sample variance, F- and pairwise t-tests with Bonferroni correction, and the non-parametric H- and u-tests. All assay results, including preliminary mineralogical information in the form of notable spectral bands, were then tested for correlation using the non-parametric Spearman's rank test.[2] For Fimmvörðuháls, four years of data were also examined for temporal trends.Biomarker quantification (other than cell count) was generally well correlated, although all assays showed notable variability even at the smallest examined spatial scale. Pairwise comparisons proved to be the most intuitive measure of variability; non-parametric characterization indicated trends at the >100 m scale, but required more replicates than were feasible at smaller scales. Future work will integrate additional

  20. Variability of gastric emptying measurements in man employing standardized radiolabeled meals

    International Nuclear Information System (INIS)

    Brophy, C.M.; Moore, J.G.; Christian, P.E.; Egger, M.J.; Taylor, A.T.

    1986-01-01

    Radiolabeled liquid and solid portions of standardized 300-g meals were administered on four different study days to eight healthy subjects in an attempt to define the range of inter- and intrasubject variability in gastric emptying. Meal half emptying times, analysis of variance, and intraclass correlations were computed and compared within and between subjects. The mean solid half emptying time was 58 +/- 17 min (range 29-92), while the mean liquid half emptying time was 24 +/- 8 min (range 12-37). A nested random effects analysis of variance showed moderate intrasubject variability for solid emptying and high intrasubject variability for liquid emptying. The variability of solid and liquid emptying was comparable and relatively large when compared with other reports in the literature. The isotopic method for measuring gastric emptying is a valuable tool for investigating problems in gastric pathophysiology, particularly when differences between groups of subjects are sought. However, meal emptying time is a variable phenomenon in healthy subjects with significant inter- and intraindividual day-to-day differences. These day-to-day variations in gastric emptying must be considered in interpreting individual study results

  1. Variability of gastric emptying measurements in man employing standardized radiolabeled meals

    Energy Technology Data Exchange (ETDEWEB)

    Brophy, C.M.; Moore, J.G.; Christian, P.E.; Egger, M.J.; Taylor, A.T.

    1986-08-01

    Radiolabeled liquid and solid portions of standardized 300-g meals were administered on four different study days to eight healthy subjects in an attempt to define the range of inter- and intrasubject variability in gastric emptying. Meal half emptying times, analysis of variance, and intraclass correlations were computed and compared within and between subjects. The mean solid half emptying time was 58 +/- 17 min (range 29-92), while the mean liquid half emptying time was 24 +/- 8 min (range 12-37). A nested random effects analysis of variance showed moderate intrasubject variability for solid emptying and high intrasubject variability for liquid emptying. The variability of solid and liquid emptying was comparable and relatively large when compared with other reports in the literature. The isotopic method for measuring gastric emptying is a valuable tool for investigating problems in gastric pathophysiology, particularly when differences between groups of subjects are sought. However, meal emptying time is a variable phenomenon in healthy subjects with significant inter- and intraindividual day-to-day differences. These day-to-day variations in gastric emptying must be considered in interpreting individual study results.

  2. Mutually unbiased coarse-grained measurements of two or more phase-space variables

    Science.gov (United States)

    Paul, E. C.; Walborn, S. P.; Tasca, D. S.; Rudnicki, Łukasz

    2018-05-01

    Mutual unbiasedness of the eigenstates of phase-space operators—such as position and momentum, or their standard coarse-grained versions—exists only in the limiting case of infinite squeezing. In Phys. Rev. Lett. 120, 040403 (2018), 10.1103/PhysRevLett.120.040403, it was shown that mutual unbiasedness can be recovered for periodic coarse graining of these two operators. Here we investigate mutual unbiasedness of coarse-grained measurements for more than two phase-space variables. We show that mutual unbiasedness can be recovered between periodic coarse graining of any two nonparallel phase-space operators. We illustrate these results through optics experiments, using the fractional Fourier transform to prepare and measure mutually unbiased phase-space variables. The differences between two and three mutually unbiased measurements is discussed. Our results contribute to bridging the gap between continuous and discrete quantum mechanics, and they could be useful in quantum-information protocols.

  3. Caliper variable sonde for thermal conductivity measurements in situ

    Energy Technology Data Exchange (ETDEWEB)

    Oelsner, C; Leischner, H; Pischel, S

    1968-01-01

    For the measurement of the thermal conductivity of the formations surrounding a borehole, a sonde having variable diameter (consisting of an inflatable rubber cylinder with heating wires embedded in its wall) is described. The conditions for the usual sonde made of metal are no longer fulfilled, but the solution to the problem of determining the thermal conductivity from the temperature rise is given, based on an approach by Carslaw and Jaeger, which contains the Bessel functions of the second kind. It is shown that a simpler solution for large values of time can be obtained through the Laplace transformation, and the necessary series developments for computer application are also given. The sonde and the necessary measuring circuitry are described. Tests measurements have indicated that the thermal conductivity can be determined with this sonde with a precision of + 10%.

  4. Portable instrumentation for quantitatively measuring radioactive surface contaminations, including 90Sr

    International Nuclear Information System (INIS)

    Brodzinski, R.L.

    1983-10-01

    In order to measure the effectiveness of decontamination efforts, a quantitative analysis of the radiocontamination is necessary, both before and after decontamination. Since it is desirable to release the decontaminated material for unrestricted use or disposal, the assay equipment must provide adequate sensitivity to measure the radioactivity at or below the release limit. In addition, the instrumentation must be capable of measuring all kinds of radiocontaminants including fission products, activation products, and transuranic materials. Finally, the survey instrumentation must be extremely versatile in order to assay the wide variety of contaminated surfaces in many environments, some of which may be extremely hostile or remote. This communication describes the development and application of portable instrumentation capable of quantitatively measuring most transuranics, activation products, and fission products, including 90 Sr, on almost any contaminated surface in nearly any location

  5. Evaluating measurement models in clinical research: covariance structure analysis of latent variable models of self-conception.

    Science.gov (United States)

    Hoyle, R H

    1991-02-01

    Indirect measures of psychological constructs are vital to clinical research. On occasion, however, the meaning of indirect measures of psychological constructs is obfuscated by statistical procedures that do not account for the complex relations between items and latent variables and among latent variables. Covariance structure analysis (CSA) is a statistical procedure for testing hypotheses about the relations among items that indirectly measure a psychological construct and relations among psychological constructs. This article introduces clinical researchers to the strengths and limitations of CSA as a statistical procedure for conceiving and testing structural hypotheses that are not tested adequately with other statistical procedures. The article is organized around two empirical examples that illustrate the use of CSA for evaluating measurement models with correlated error terms, higher-order factors, and measured and latent variables.

  6. Correlations between Sportsmen’s Morpho-Functional Measurements and Voice Acoustic Variables

    Directory of Open Access Journals (Sweden)

    Rexhepi Agron M.

    2016-12-01

    Full Text Available Purpose. Since human voice characteristics are specific to each individual, numerous anthropological studies have been oriented to find significant relationships between voice and morpho-functional features. The goal of this study was to identify the correlation between seven morpho-functional variables and six voice acoustic parameters in sportsmen. Methods. Following the protocols of the International Biological Program, seven morpho-functional variables and six voice acoustic parameters have been measured in 88 male professional athletes from Kosovo, aged 17-35 years, during the period of April-October 2013. The statistical analysis was accomplished through the SPSS program, version 20. The obtained data were analysed through descriptive parameters and with Spearman’s method of correlation analysis. Results. Spearman’s method of correlation showed significant negative correlations (R = -0.215 to -0.613; p = 0.05 between three voice acoustic variables of the fundamental frequency of the voice sample (Mean, Minimum, and Maximum Pitch and six morpho-functional measures (Body Height, Body Weight, Margaria-Kalamen Power Test, Sargent Jump Test, Pull-up Test, and VO2max.abs. Conclusions. The significant correlations imply that the people with higher stature have longer vocal cords and a lower voice. These results encourage investigations on predicting sportsmen’s functional abilities on the basis of their voice acoustic parameters.

  7. Correlation between measured energy expenditure and clinically obtained variables in trauma and sepsis patients.

    Science.gov (United States)

    Frankenfield, D C; Omert, L A; Badellino, M M; Wiles, C E; Bagley, S M; Goodarzi, S; Siegel, J H

    1994-01-01

    Indirect calorimetry is the preferred method for determining caloric requirements of patients, but availability of the device is limited by high cost. A study was therefore conducted to determine whether clinically obtainable variables could be used to predict metabolic rate. Patients with severe trauma or sepsis who required mechanical ventilation were measured by an open-circuit indirect calorimeter. Several clinical variables were obtained simultaneously. Measurements were repeated every 12 hours for up to 10 days. Twenty-six trauma and 30 sepsis patients were measured 423 times. Mean resting energy expenditure was 36 +/- 7 kcal/kg (trauma) vs 45 +/- 8 kcal/kg (sepsis) (p types.

  8. Variability of creatinine measurements in clinical laboratories: results from the CRIC study.

    Science.gov (United States)

    Joffe, Marshall; Hsu, Chi-yuan; Feldman, Harold I; Weir, Matthew; Landis, J R; Hamm, L Lee

    2010-01-01

    Estimating equations using serum creatinine (SCr) are often used to assess glomerular filtration rate (GFR). Such creatinine (Cr)-based formulae may produce biased estimates of GFR when using Cr measurements that have not been calibrated to reference laboratories. In this paper, we sought to examine the degree of this variation in Cr assays in several laboratories associated with academic medical centers affiliated with the Chronic Renal Insufficiency Cohort (CRIC) Study; to consider how best to correct for this variation, and to quantify the impact of such corrections on eligibility for participation in CRIC. Variability of Cr is of particular concern in the conduct of CRIC, a large multicenter study of subjects with chronic renal disease, because eligibility for the study depends on Cr-based assessment of GFR. A library of 5 large volume plasma specimens from apheresis patients was assembled, representing levels of plasma Cr from 0.8 to 2.4 mg/dl. Samples from this library were used for measurement of Cr at each of the 14 CRIC laboratories repetitively over time. We used graphical displays and linear regression methods to examine the variability in Cr, and used linear regression to develop calibration equations. We also examined the impact of the various calibration equations on the proportion of subjects screened as potential participants who were actually eligible for the study. There was substantial variability in Cr assays across laboratories and over time. We developed calibration equations for each laboratory; these equations varied substantially among laboratories and somewhat over time in some laboratories. The laboratory site contributed the most to variability (51% of the variance unexplained by the specimen) and variation with time accounted for another 15%. In some laboratories, calibration equations resulted in differences in eligibility for CRIC of as much as 20%. The substantial variability in SCr assays across laboratories necessitates calibration

  9. Prediction of preterm birth in multiple pregnancies: development of a multivariable model including cervical length measurement at 16 to 21 weeks' gestation.

    Science.gov (United States)

    van de Mheen, Lidewij; Schuit, Ewoud; Lim, Arianne C; Porath, Martina M; Papatsonis, Dimitri; Erwich, Jan J; van Eyck, Jim; van Oirschot, Charlotte M; Hummel, Piet; Duvekot, Johannes J; Hasaart, Tom H M; Groenwold, Rolf H H; Moons, Karl G M; de Groot, Christianne J M; Bruinse, Hein W; van Pampus, Maria G; Mol, Ben W J

    2014-04-01

    To develop a multivariable prognostic model for the risk of preterm delivery in women with multiple pregnancy that includes cervical length measurement at 16 to 21 weeks' gestation and other variables. We used data from a previous randomized trial. We assessed the association between maternal and pregnancy characteristics including cervical length measurement at 16 to 21 weeks' gestation and time to delivery using multivariable Cox regression modelling. Performance of the final model was assessed for the outcomes of preterm and very preterm delivery using calibration and discrimination measures. We studied 507 women, of whom 270 (53%) delivered models for preterm and very preterm delivery had a c-index of 0.68 (95% CI 0.63 to 0.72) and 0.68 (95% CI 0.62 to 0.75), respectively, and showed good calibration. In women with a multiple pregnancy, the risk of preterm delivery can be assessed with a multivariable model incorporating cervical length and other predictors.

  10. Effect of trotting speed on kinematic variables measured by use of extremity-mounted inertial measurement units in nonlame horses performing controlled treadmill exercise.

    Science.gov (United States)

    Cruz, Antonio M; Vidondo, Beatriz; Ramseyer, Alessandra A; Maninchedda, Ugo E

    2018-02-01

    OBJECTIVE To assess effects of speed on kinematic variables measured by use of extremity-mounted inertial measurement units (IMUs) in nonlame horses performing controlled exercise on a treadmill. ANIMALS 10 nonlame horses. PROCEDURES 6 IMUs were attached at predetermined locations on 10 nonlame Franches Montagnes horses. Data were collected in triplicate during trotting at 3.33 and 3.88 m/s on a high-speed treadmill. Thirty-three selected kinematic variables were analyzed. Repeated-measures ANOVA was used to assess the effect of speed. RESULTS Significant differences between the 2 speeds were detected for most temporal (11/14) and spatial (12/19) variables. The observed spatial and temporal changes would translate into a gait for the higher speed characterized by increased stride length, protraction and retraction, flexion and extension, mediolateral movement of the tibia, and symmetry, but with similar temporal variables and a reduction in stride duration. However, even though the tibia coronal range of motion was significantly different between speeds, the high degree of variability raised concerns about whether these changes were clinically relevant. For some variables, the lower trotting speed apparently was associated with more variability than was the higher trotting speed. CONCLUSIONS AND CLINICAL RELEVANCE At a higher trotting speed, horses moved in the same manner (eg, the temporal events investigated occurred at the same relative time within the stride). However, from a spatial perspective, horses moved with greater action of the segments evaluated. The detected changes in kinematic variables indicated that trotting speed should be controlled or kept constant during gait evaluation.

  11. Methodology for setup and data processing of mobile air quality measurements to assess the spatial variability of concentrations in urban environments

    International Nuclear Information System (INIS)

    Van Poppel, Martine; Peters, Jan; Bleux, Nico

    2013-01-01

    A case study is presented to illustrate a methodology for mobile monitoring in urban environments. A dataset of UFP, PM 2.5 and BC concentrations was collected. We showed that repeated mobile measurements could give insight in spatial variability of pollutants at different micro-environments in a city. Streets of contrasting traffic intensity showed increased concentrations by a factor 2–3 for UFP and BC and by 2.5 . The first quartile (P25) of the mobile measurements at an urban background zone seems to be good estimate of the urban background concentration. The local component of the pollutant concentrations was determined by background correction. The use of background correction reduced the number of runs needed to obtain representative results. The results presented, are a first attempt to establish a methodology for setup and data processing of mobile air quality measurements to assess the spatial variability of concentrations in urban environments. -- Highlights: ► Mobile measurements are used to assess the variability of air pollutants in urban environments. ► PM 2.5 , BC and UFP concentrations are presented for zones with different traffic characteristics. ► A methodology for background correction based on the mobile measurements is presented. ► The background concentration is estimated as the 25th percentile of the urban background data. ► The minimum numbers of runs for a representative estimate is reduced after background correction. -- This paper shows that the spatial variability of air pollutants in an urban environment can be assessed by a mobile monitoring methodology including background correction

  12. Variability in measured current structure on the southwest continental shelf of India

    Digital Repository Service at National Institute of Oceanography (India)

    DineshKumar, P.K.; Srinivas, K.

    -1 Variability in Measured Current Structure on the Southwest Continental Shelf of India P.K. Dinesh Kumar and K. Srinivas National Institute of Oceanography, Regional Centre P.O.Box 1913, Cochin - 682018,India Email: dineshku@niokochi.org ABSTRACT... WORDS: Direct current measurements, tidal currents, southwest coast of India. INTRODUCTION The circulation pattern of the eastern Arabian Sea over the southwest continental shelf of India (inferred...

  13. VARIABILITY OF MANUAL AND COMPUTERIZED METHODS FOR MEASURING CORONAL VERTEBRAL INCLINATION IN COMPUTED TOMOGRAPHY IMAGES

    Directory of Open Access Journals (Sweden)

    Tomaž Vrtovec

    2015-06-01

    Full Text Available Objective measurement of coronal vertebral inclination (CVI is of significant importance for evaluating spinal deformities in the coronal plane. The purpose of this study is to systematically analyze and compare manual and computerized measurements of CVI in cross-sectional and volumetric computed tomography (CT images. Three observers independently measured CVI in 14 CT images of normal and 14 CT images of scoliotic vertebrae by using six manual and two computerized measurements. Manual measurements were obtained in coronal cross-sections by manually identifying the vertebral body corners, which served to measure CVI according to the superior and inferior tangents, left and right tangents, and mid-endplate and mid-wall lines. Computerized measurements were obtained in two dimensions (2D and in three dimensions (3D by manually initializing an automated method in vertebral centroids and then searching for the planes of maximal symmetry of vertebral anatomical structures. The mid-endplate lines were the most reproducible and reliable manual measurements (intra- and inter-observer variability of 0.7° and 1.2° standard deviation, SD, respectively. The computerized measurements in 3D were more reproducible and reliable (intra- and inter-observer variability of 0.5° and 0.7° SD, respectively, but were most consistent with the mid-wall lines (2.0° SD and 1.4° mean absolute difference. The manual CVI measurements based on mid-endplate lines and the computerized CVI measurements in 3D resulted in the lowest intra-observer and inter-observer variability, however, computerized CVI measurements reduce observer interaction.

  14. Clinical Implications of Glucose Variability: Chronic Complications of Diabetes

    Directory of Open Access Journals (Sweden)

    Hye Seung Jung

    2015-06-01

    Full Text Available Glucose variability has been identified as a potential risk factor for diabetic complications; oxidative stress is widely regarded as the mechanism by which glycemic variability induces diabetic complications. However, there remains no generally accepted gold standard for assessing glucose variability. Representative indices for measuring intraday variability include calculation of the standard deviation along with the mean amplitude of glycemic excursions (MAGE. MAGE is used to measure major intraday excursions and is easily measured using continuous glucose monitoring systems. Despite a lack of randomized controlled trials, recent clinical data suggest that long-term glycemic variability, as determined by variability in hemoglobin A1c, may contribute to the development of microvascular complications. Intraday glycemic variability is also suggested to accelerate coronary artery disease in high-risk patients.

  15. Resolving meso-scale seabed variability using reflection measurements from an autonomous underwater vehicle.

    Science.gov (United States)

    Holland, Charles W; Nielsen, Peter L; Dettmer, Jan; Dosso, Stan

    2012-02-01

    Seabed geoacoustic variability is driven by geological processes that occur over a wide spectrum of space-time scales. While the acoustics community has some understanding of horizontal fine-scale geoacoustic variability, less than O(10(0)) m, and large-scale variability, greater than O(10(3)) m, there is a paucity of data resolving the geoacoustic meso-scale O(10(0)-10(3)) m. Measurements of the meso-scale along an ostensibly "benign" portion of the outer shelf reveal three classes of variability. The first class was expected and is due to horizontal variability of layer thicknesses: this was the only class that could be directly tied to seismic reflection data. The second class is due to rapid changes in layer properties and/or boundaries, occurring over scales of meters to hundreds of meters. The third class was observed as rapid variations of the angle/frequency dependent reflection coefficient within a single observation and is suggestive of variability at scales of meter or less. Though generally assumed to be negligible in acoustic modeling, the second and third classes are indicative of strong horizontal geoacoustic variability within a given layer. The observations give early insight into possible effects of horizontal geoacoustic variability on long-range acoustic propagation and reverberation. © 2012 Acoustical Society of America

  16. Interobserver and Intraobserver Variability among Measurements of FDG PET/CT Parameters in Pulmonary Tumors

    Directory of Open Access Journals (Sweden)

    Gülgün Büyükdereli

    2016-06-01

    Full Text Available Background: 18F-fluorodeoxyglucose (FDG positron emission tomography computed tomography (PET/CT provides information about metabolic and morphologic status of malignancies. Tumor size and standardized uptake value (SUV measurements are crucial for cancer treatment monitoring.: 18F-fluorodeoxyglucose (FDG positron emission tomography computed tomography (PET/CT provides information about metabolic and morphologic status of malignancies. Tumor size and standardized uptake value (SUV measurements are crucial for cancer treatment monitoring. Aims: The purpose of our study was to assess the variability of these measurements performed by observers evaluating lung tumors. Study Design: Retrospective cross-sectional study. Methods: FDG PET/CT images of 97 patients with pulmonary tumors were independently evaluated by two experienced nuclear medicine physicians. Primary tumor size (UDCT, maximum SUV (SUVmax, mean SUV (SUVmean and maximum SUV normalized to liver mean SUV (SUVnliv max were measured by each observer at two different times with an interval of at least 2 weeks. Interobserver and intraobserver variabilities of measurements were evaluated through statistical methods. Results: Size of the lesions varied from 0.81 to 13.6 cm (mean 4.29±2.24 cm. Very good agreement was shown with correlation, Bland-Altman and regression analysis for all measured PET/CT parameters. In the interobserver and intraobserver variability analysis, the Pearson correlation coefficients were greater than 0.96 and 0.98, respectively. Conclusion: Semi-quantitative measurements of pulmonary tumors were highly reproducible when determined by experienced physicians with clinically available software for routine FDG PET/CT evaluation. Consistency may be improved if the same observer performs serial measurements for any one patient.

  17. Analysis and modeling of wafer-level process variability in 28 nm FD-SOI using split C-V measurements

    Science.gov (United States)

    Pradeep, Krishna; Poiroux, Thierry; Scheer, Patrick; Juge, André; Gouget, Gilles; Ghibaudo, Gérard

    2018-07-01

    This work details the analysis of wafer level global process variability in 28 nm FD-SOI using split C-V measurements. The proposed approach initially evaluates the native on wafer process variability using efficient extraction methods on split C-V measurements. The on-wafer threshold voltage (VT) variability is first studied and modeled using a simple analytical model. Then, a statistical model based on the Leti-UTSOI compact model is proposed to describe the total C-V variability in different bias conditions. This statistical model is finally used to study the contribution of each process parameter to the total C-V variability.

  18. Using atmospheric 14CO to constrain OH variability: concept and potential for future measurements

    Science.gov (United States)

    Petrenko, V. V.; Murray, L. T.; Smith, A. W.

    2017-12-01

    The primary source of 14C-containing carbon monoxide (14CO) in the atmosphere is via 14C production from 14N by secondary cosmic rays, and the primary sink is removal by OH. Variations in the global abundance of 14CO that are not explained by variations in 14C production are mainly driven by variations in the global abundance of OH. Monitoring OH variability via methyl chloroform is becoming increasingly difficult as methyl chloroform abundance is continuing to decline. Measurements of atmospheric 14CO have previously been successfully used to infer OH variability. However, these measurements are currently only continuing at one location (Baring Head, New Zealand), which is insufficient to infer global trends. We propose to restart global 14CO monitoring with the aim of providing another constraint on OH variability. A new analytical system for 14CO sampling and measurements is in development, which will allow to strongly reduce the required sample air volumes (previously ≥ 400 L) and simplify field logistics. A set of test measurements is planned, with sampling at the Mauna Loa Observatory. Preliminary work with a state-of-the-art chemical transport model is identifying the most promising locations for global 14CO sampling.

  19. Determining the Variability of Lesion Size Measurements from CT Patient Data Sets Acquired under “No Change” Conditions

    Directory of Open Access Journals (Sweden)

    Michael F. McNitt-Gray

    2015-02-01

    Full Text Available PURPOSE: To determine the variability of lesion size measurements in computed tomography data sets of patients imaged under a “no change” (“coffee break” condition and to determine the impact of two reading paradigms on measurement variability. METHOD AND MATERIALS: Using data sets from 32 non-small cell lung cancer patients scanned twice within 15 minutes (“no change”, measurements were performed by five radiologists in two phases: (1 independent reading of each computed tomography dataset (timepoint: (2 a locked, sequential reading of datasets. Readers performed measurements using several sizing methods, including one-dimensional (1D longest in-slice dimension and 3D semi-automated segmented volume. Change in size was estimated by comparing measurements performed on both timepoints for the same lesion, for each reader and each measurement method. For each reading paradigm, results were pooled across lesions, across readers, and across both readers and lesions, for each measurement method. RESULTS: The mean percent difference (±SD when pooled across both readers and lesions for 1D and 3D measurements extracted from contours was 2.8 ± 22.2% and 23.4 ± 105.0%, respectively, for the independent reads. For the locked, sequential reads, the mean percent differences (±SD reduced to 2.52 ± 14.2% and 7.4 ± 44.2% for the 1D and 3D measurements, respectively. CONCLUSION: Even under a “no change” condition between scans, there is variation in lesion size measurements due to repeat scans and variations in reader, lesion, and measurement method. This variation is reduced when using a locked, sequential reading paradigm compared to an independent reading paradigm.

  20. Fault-tolerant measurement-based quantum computing with continuous-variable cluster states.

    Science.gov (United States)

    Menicucci, Nicolas C

    2014-03-28

    A long-standing open question about Gaussian continuous-variable cluster states is whether they enable fault-tolerant measurement-based quantum computation. The answer is yes. Initial squeezing in the cluster above a threshold value of 20.5 dB ensures that errors from finite squeezing acting on encoded qubits are below the fault-tolerance threshold of known qubit-based error-correcting codes. By concatenating with one of these codes and using ancilla-based error correction, fault-tolerant measurement-based quantum computation of theoretically indefinite length is possible with finitely squeezed cluster states.

  1. High-precision 41K/39K measurements by MC-ICP-MS indicate terrestrial variability of δ41K

    Science.gov (United States)

    Morgan, Leah; Santiago Ramos, Danielle P.; Davidheiser-Kroll, Brett; Faithfull, John; Lloyd, Nicholas S.; Ellam, Rob M.; Higgins, John A.

    2018-01-01

    Potassium is a major component in continental crust, the fourth-most abundant cation in seawater, and a key element in biological processes. Until recently, difficulties with existing analytical techniques hindered our ability to identify natural isotopic variability of potassium isotopes in terrestrial materials. However, measurement precision has greatly improved and a range of K isotopic compositions has now been demonstrated in natural samples. In this study, we present a new technique for high-precision measurement of K isotopic ratios using high-resolution, cold plasma multi-collector mass spectrometry. We apply this technique to demonstrate natural variability in the ratio of 41K to 39K in a diverse group of geological and biological samples, including silicate and evaporite minerals, seawater, and plant and animal tissues. The total range in 41K/39K ratios is ca. 2.6‰, with a long-term external reproducibility of 0.17‰ (2, N=108). Seawater and seawater-derived evaporite minerals are systematically enriched in 41K compared to silicate minerals by ca. 0.6‰, a result consistent with recent findings1, 2. Although our average bulk-silicate Earth value (-0.54‰) is indistinguishable from previously published values, we find systematic δ41K variability in some high-temperature sample suites, particularly those with evidence for the presence of fluids. The δ41K values of biological samples span a range of ca. 1.2‰ between terrestrial mammals, plants, and marine organisms. Implications of terrestrial K isotope variability for the atomic weight of K and K-based geochronology are discussed. Our results indicate that high-precision measurements of stable K isotopes, made using commercially available mass spectrometers, can provide unique insights into the chemistry of potassium in geological and biological systems. 

  2. Coronary Artery Calcium Distribution and Interscan Measurement Variability in End-Stage Renal and Coronary Heart Disease Patients

    International Nuclear Information System (INIS)

    Serafin, Z.; Laskowska, K.; Marzec, M.; Lasek, W.; Sinjab, T.A.; Wlodarczyk, Z.

    2009-01-01

    Background: Coronary heart disease patients and end-stage renal disease patients have been documented to have an increased amount of coronary artery calcifications (CAC). Purpose: To evaluate the distribution of CAC and its influence on interscan variability of measurement in end-stage renal disease and coronary heart disease patients, proven to have calcifications. Material and Methods: 69 patients having CAC, including 34 with coronary heart disease and 35 with end-stage renal disease, were scanned twice with multidetector-row computed tomography (MDCT). Amount of CAC was determined as the number of calcified lesions (CN), total calcium score (CS), calcium volume (CV), and calcium mass (CM). Distribution of CAC was evaluated on a per-patient basis as the median CS and CM of a single lesion. Density of the calcifications was calculated as the patient's CM divided by CV. Results: The overall median CS was 457.2, and the median CM was 75.6 mg. There were no significant differences in the number of calcified lesions, CS, or CM between the two groups. Both CS and CM of a single lesion, as well as the mean calcium density were lower in renal disease patients (P<0.05) than in coronary heart disease subjects. The relative interscan variability of coronary calcium measurement was higher in the renal disease group (P<0.05). There was a negative correlation between the calcium concentration and the relative interscan variability. Conclusion: The results indicate that the coronary calcium distribution influences the measurement interscan reproducibility, and the distribution may differ between end-stage renal disease patients and coronary heart disease patients, reflecting the dissimilar nature of coronary calcifications in those groups

  3. Coronary Artery Calcium Distribution and Interscan Measurement Variability in End-Stage Renal and Coronary Heart Disease Patients

    Energy Technology Data Exchange (ETDEWEB)

    Serafin, Z.; Laskowska, K.; Marzec, M.; Lasek, W. (Dept. of Radiology and Diagnostic Imaging, Nicolaus Copernicus Univ., Collegium Medicum, Bydgoszcz (Poland)); Sinjab, T.A.; Wlodarczyk, Z. (Dept. of Transplantology, Nicolaus Copernicus Univ., Collegium Medicum, Bydgoszcz (Poland))

    2009-04-15

    Background: Coronary heart disease patients and end-stage renal disease patients have been documented to have an increased amount of coronary artery calcifications (CAC). Purpose: To evaluate the distribution of CAC and its influence on interscan variability of measurement in end-stage renal disease and coronary heart disease patients, proven to have calcifications. Material and Methods: 69 patients having CAC, including 34 with coronary heart disease and 35 with end-stage renal disease, were scanned twice with multidetector-row computed tomography (MDCT). Amount of CAC was determined as the number of calcified lesions (CN), total calcium score (CS), calcium volume (CV), and calcium mass (CM). Distribution of CAC was evaluated on a per-patient basis as the median CS and CM of a single lesion. Density of the calcifications was calculated as the patient's CM divided by CV. Results: The overall median CS was 457.2, and the median CM was 75.6 mg. There were no significant differences in the number of calcified lesions, CS, or CM between the two groups. Both CS and CM of a single lesion, as well as the mean calcium density were lower in renal disease patients (P<0.05) than in coronary heart disease subjects. The relative interscan variability of coronary calcium measurement was higher in the renal disease group (P<0.05). There was a negative correlation between the calcium concentration and the relative interscan variability. Conclusion: The results indicate that the coronary calcium distribution influences the measurement interscan reproducibility, and the distribution may differ between end-stage renal disease patients and coronary heart disease patients, reflecting the dissimilar nature of coronary calcifications in those groups.

  4. Temporal variability of TEC deduced from groundbased measurements

    International Nuclear Information System (INIS)

    Mosert, M.; Ezquer, R.G.; Jadur, C.; Radicella, S.M.

    2001-01-01

    This paper presents a study of the behaviour of the integrated total electron content (ITEC) deduced from electron density profiles of two Argentine stations: Tucuman (26.9 S; 294.6 E) and San Juan (31.5 S; 290.4 E). The ITEC values have been obtained by the technique proposed by Reinisch and Huang (2000). The database includes electron density profiles derived from ionograms recorded at 4 typical hours of the day (00.00, 06.00, 12.00 and 18.00 LT) during different seasonal and solar activity conditions. An analysis of the day to day variability of ITEC has also been done. (author)

  5. Continuous-variable measurement-device-independent quantum key distribution with virtual photon subtraction

    Science.gov (United States)

    Zhao, Yijia; Zhang, Yichen; Xu, Bingjie; Yu, Song; Guo, Hong

    2018-04-01

    The method of improving the performance of continuous-variable quantum key distribution protocols by postselection has been recently proposed and verified. In continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocols, the measurement results are obtained from untrusted third party Charlie. There is still not an effective method of improving CV-MDI QKD by the postselection with untrusted measurement. We propose a method to improve the performance of coherent-state CV-MDI QKD protocol by virtual photon subtraction via non-Gaussian postselection. The non-Gaussian postselection of transmitted data is equivalent to an ideal photon subtraction on the two-mode squeezed vacuum state, which is favorable to enhance the performance of CV-MDI QKD. In CV-MDI QKD protocol with non-Gaussian postselection, two users select their own data independently. We demonstrate that the optimal performance of the renovated CV-MDI QKD protocol is obtained with the transmitted data only selected by Alice. By setting appropriate parameters of the virtual photon subtraction, the secret key rate and tolerable excess noise are both improved at long transmission distance. The method provides an effective optimization scheme for the application of CV-MDI QKD protocols.

  6. How to include the variability of TMS responses in simulations: a speech mapping case study

    Science.gov (United States)

    De Geeter, N.; Lioumis, P.; Laakso, A.; Crevecoeur, G.; Dupré, L.

    2016-11-01

    When delivered over a specific cortical site, TMS can temporarily disrupt the ongoing process in that area. This allows mapping of speech-related areas for preoperative evaluation purposes. We numerically explore the observed variability of TMS responses during a speech mapping experiment performed with a neuronavigation system. We selected four cases with very small perturbations in coil position and orientation. In one case (E) a naming error occurred, while in the other cases (NEA, B, C) the subject appointed the images as smoothly as without TMS. A realistic anisotropic head model was constructed of the subject from T1-weighted and diffusion-weighted MRI. The induced electric field distributions were computed, associated to the coil parameters retrieved from the neuronavigation system. Finally, the membrane potentials along relevant white matter fibre tracts, extracted from DTI-based tractography, were computed using a compartmental cable equation. While only minor differences could be noticed between the induced electric field distributions of the four cases, computing the corresponding membrane potentials revealed different subsets of tracts were activated. A single tract was activated for all coil positions. Another tract was only triggered for case E. NEA induced action potentials in 13 tracts, while NEB stimulated 11 tracts and NEC one. The calculated results are certainly sensitive to the coil specifications, demonstrating the observed variability in this study. However, even though a tract connecting Broca’s with Wernicke’s area is only triggered for the error case, further research is needed on other study cases and on refining the neural model with synapses and network connections. Case- and subject-specific modelling that includes both electromagnetic fields and neuronal activity enables demonstration of the variability in TMS experiments and can capture the interaction with complex neural networks.

  7. Contextuality in canonical systems of random variables

    Science.gov (United States)

    Dzhafarov, Ehtibar N.; Cervantes, Víctor H.; Kujala, Janne V.

    2017-10-01

    Random variables representing measurements, broadly understood to include any responses to any inputs, form a system in which each of them is uniquely identified by its content (that which it measures) and its context (the conditions under which it is recorded). Two random variables are jointly distributed if and only if they share a context. In a canonical representation of a system, all random variables are binary, and every content-sharing pair of random variables has a unique maximal coupling (the joint distribution imposed on them so that they coincide with maximal possible probability). The system is contextual if these maximal couplings are incompatible with the joint distributions of the context-sharing random variables. We propose to represent any system of measurements in a canonical form and to consider the system contextual if and only if its canonical representation is contextual. As an illustration, we establish a criterion for contextuality of the canonical system consisting of all dichotomizations of a single pair of content-sharing categorical random variables. This article is part of the themed issue `Second quantum revolution: foundational questions'.

  8. Evaluation of the Wind Flow Variability Using Scanning Doppler Lidar Measurements

    Science.gov (United States)

    Sand, S. C.; Pichugina, Y. L.; Brewer, A.

    2016-12-01

    Better understanding of the wind flow variability at the heights of the modern turbines is essential to accurately assess of generated wind power and efficient turbine operations. Nowadays the wind energy industry often utilizes scanning Doppler lidar to measure wind-speed profiles at high spatial and temporal resolution.The study presents wind flow features captured by scanning Doppler lidars during the second Wind Forecast and Improvement Project (WFIP 2) sponsored by the Department of Energy (DOE) and National Oceanic and Atmospheric Administration (NOAA). This 18-month long experiment in the Columbia River Basin aims to improve model wind forecasts complicated by mountain terrain, coastal effects, and numerous wind farms.To provide a comprehensive dataset to use for characterizing and predicting meteorological phenomena important to Wind Energy, NOAA deployed scanning, pulsed Doppler lidars to two sites in Oregon, one at Wasco, located upstream of all wind farms relative to the predominant westerly flow in the region, and one at Arlington, located in the middle of several wind farms.In this presentation we will describe lidar scanning patterns capable of providing data in conical, or vertical-slice modes. These individual scans were processed to obtain 15-min averaged profiles of wind speed and direction in real time. Visualization of these profiles as time-height cross sections allows us to analyze variability of these parameters with height, time and location, and reveal periods of rapid changes (ramp events). Examples of wind flow variability between two sites of lidar measurements along with examples of reduced wind velocity downwind of operating turbines (wakes) will be presented.

  9. Hypocretin measurement: shelf age of radioimmunoassay kit, but not freezer time, influences assay variability.

    Science.gov (United States)

    Keating, Glenda; Bliwise, Donald L; Saini, Prabhjyot; Rye, David B; Trotti, Lynn Marie

    2017-09-01

    The hypothalamic peptide hypocretin 1 (orexin A) may be assayed in cerebrospinal fluid to diagnose narcolepsy type 1. This testing is not commercially available, and factors contributing to assay variability have not previously been comprehensively explored. In the present study, cerebrospinal fluid hypocretin concentrations were determined in duplicate in 155 patient samples, across a range of sleep disorders. Intra-assay variability of these measures was analyzed. Inter-assay correlation between samples tested at Emory and at Stanford was high (r = 0.79, p hypocretin values, such that kits closer to expiration exhibit significantly more variability.

  10. Simultaneously measured pupillary light reflex and heart rate variability in healthy children

    International Nuclear Information System (INIS)

    Daluwatte, C; Yao, G; Miles, J H

    2012-01-01

    We investigated the potential inter-relationship between two measures of autonomic nervous system: pupillary light reflex (PLR) and heart rate variability (HRV), in healthy children of 8–16 years old. PLR was measured at both dark- and light-adapted conditions with various stimulation intensities. Simultaneously measured HRV was obtained in five different PLR testing phases: before PLR test, light-adapted PLR test, dark adaptation, dark-adapted PLR test and after PLR test. The frequency domain HRV parameters measured during the PLR test were significantly different from those measured during rest. Both the regression analysis and factor analysis indicated that PLR and HRV parameters were not correlated, which suggests that they may provide complementary assessment of different aspects of the overall autonomic nervous system. (paper)

  11. Simultaneously measured pupillary light reflex and heart rate variability in healthy children

    Energy Technology Data Exchange (ETDEWEB)

    Daluwatte, C; Yao, G [Department of Biological Engineering, University of Missouri, Columbia, MO 65211 (United States); Miles, J H, E-mail: YaoG@missouri.edu [Child Health and Thompson Center for Autism and Neurodevelopmental Disorders, University of Missouri, Columbia, MO 65211 (United States)

    2012-06-15

    We investigated the potential inter-relationship between two measures of autonomic nervous system: pupillary light reflex (PLR) and heart rate variability (HRV), in healthy children of 8–16 years old. PLR was measured at both dark- and light-adapted conditions with various stimulation intensities. Simultaneously measured HRV was obtained in five different PLR testing phases: before PLR test, light-adapted PLR test, dark adaptation, dark-adapted PLR test and after PLR test. The frequency domain HRV parameters measured during the PLR test were significantly different from those measured during rest. Both the regression analysis and factor analysis indicated that PLR and HRV parameters were not correlated, which suggests that they may provide complementary assessment of different aspects of the overall autonomic nervous system. (paper)

  12. In situ measurements of the NO{sub x} distribution and variability over the eastern North Atlantic

    Energy Technology Data Exchange (ETDEWEB)

    Ziereis, H.; Schlager, H.; Schulte, P.; Koehler, I.; Marquardt, R.; Feigl, C.

    1998-11-01

    Between 1994 and 1996 the research aircraft Falcon of the ``Deutsches Zentrum fuer Luft- und Raumfahrt (DLR)`` was used to probe the upper troposphere and lowermost stratosphere over the eastern North Atlantic. In situ measurements of NO, NO{sub 2}, and O{sub 3} were performed during 32 flights. The measurements were carried out during five aircraft campaigns in summer and late autumn, respectively, based from Shannon/Ireland and Prestwick/Scotland. Most of the flights were conducted in the region of the North Atlantic flight corridor. Main objectives of these measurements included the study of the large scale distribution of NO and NO{sub x} and the development of a ``climatology`` of NO{sub x} in a region of the atmosphere that is strongly affected by aircraft emissions. Substantial variability of NO and NO{sub x} volume mixing ratios was observed in the upper troposphere and lowermost stratosphere. In spite of this variability a significant seasonal dependence was found. NO mean values (averages over all measurements made during one campaign) at altitudes between 10,500 and 11,500 m, where most of the data have been obtained, ranged between about 0.1 and 0.14 ppbv in summer and 0.03 and 0.10 ppbv in late autumn. NO and NO{sub x} did not show a significant gradient across the tropopause. The correlation between NO{sub x} and O{sub 3} in the upper troposphere and lowermost stratosphere was only very weak. The present measurements represent a suitable data set for comparison with predictions of the NO{sub x} distribution in the upper troposphere over the eastern North Atlantic by three dimensional models. A comparison with the NO{sub x} fields simulated with the climate model ECHAM 3 extended by a simplified NO{sub x} chemistry reveals good agreement for summer and autumn conditions. (orig.) 44 refs.

  13. Original method to compute epipoles using variable homography: application to measure emergent fibers on textile fabrics

    Science.gov (United States)

    Xu, Jun; Cudel, Christophe; Kohler, Sophie; Fontaine, Stéphane; Haeberlé, Olivier; Klotz, Marie-Louise

    2012-04-01

    Fabric's smoothness is a key factor in determining the quality of finished textile products and has great influence on the functionality of industrial textiles and high-end textile products. With popularization of the zero defect industrial concept, identifying and measuring defective material in the early stage of production is of great interest to the industry. In the current market, many systems are able to achieve automatic monitoring and control of fabric, paper, and nonwoven material during the entire production process, however online measurement of hairiness is still an open topic and highly desirable for industrial applications. We propose a computer vision approach to compute epipole by using variable homography, which can be used to measure emergent fiber length on textile fabrics. The main challenges addressed in this paper are the application of variable homography on textile monitoring and measurement, as well as the accuracy of the estimated calculation. We propose that a fibrous structure can be considered as a two-layer structure, and then we show how variable homography combined with epipolar geometry can estimate the length of the fiber defects. Simulations are carried out to show the effectiveness of this method. The true length of selected fibers is measured precisely using a digital optical microscope, and then the same fibers are tested by our method. Our experimental results suggest that smoothness monitored by variable homography is an accurate and robust method of quality control for important industrial fabrics.

  14. The effect of virtual reality on gait variability.

    Science.gov (United States)

    Katsavelis, Dimitrios; Mukherjee, Mukul; Decker, Leslie; Stergiou, Nicholas

    2010-07-01

    Optic Flow (OF) plays an important role in human locomotion and manipulation of OF characteristics can cause changes in locomotion patterns. The purpose of the study was to investigate the effect of the velocity of optic flow on the amount and structure of gait variability. Each subject underwent four conditions of treadmill walking at their self-selected pace. In three conditions the subjects walked in an endless virtual corridor, while a fourth control condition was also included. The three virtual conditions differed in the speed of the optic flow displayed as follows--same speed (OFn), faster (OFf), and slower (OFs) than that of the treadmill. Gait kinematics were tracked with an optical motion capture system. Gait variability measures of the hip, knee and ankle range of motion and stride interval were analyzed. Amount of variability was evaluated with linear measures of variability--coefficient of variation, while structure of variability i.e., its organization over time, were measured with nonlinear measures--approximate entropy and detrended fluctuation analysis. The linear measures of variability, CV, did not show significant differences between Non-VR and VR conditions while nonlinear measures of variability identified significant differences at the hip, ankle, and in stride interval. In response to manipulation of the optic flow, significant differences were observed between the three virtual conditions in the following order: OFn greater than OFf greater than OFs. Measures of structure of variability are more sensitive to changes in gait due to manipulation of visual cues, whereas measures of the amount of variability may be concealed by adaptive mechanisms. Visual cues increase the complexity of gait variability and may increase the degrees of freedom available to the subject. Further exploration of the effects of optic flow manipulation on locomotion may provide us with an effective tool for rehabilitation of subjects with sensorimotor issues.

  15. Three-dimensional Mass Measurement of Subsolid Pulmonary Nodules on Chest CT: Intra and Inter-observer Variability

    Directory of Open Access Journals (Sweden)

    Huiting LIU

    2015-05-01

    Full Text Available Background and objective Subsolid pulmonary nodules tend to exhibit considerably slower growth rates than solid lesions, nevertheless, higher malignancy probability. The diagnosis of indeterminate nodules largely depends on the growth evaluation during follow-up. The growth can manifested as an increase in size or the appearance and/or subsequent increase of solid components. The mass reflect the product of volume and density and can be more sensitive in growth evaluation. However, the repeatability needs a further validation. The purpose of this study is to assess the intra and inter-observer variability of mass measurement for subsolid nodules. Methods 80 subsolid nodules in 44 patients were retrospectively enrolled. Both the volume and mass were measured by two radiologists using blind method independently. Intra-observer and inter-observer variability were analyzed and compared by Bland-Altman method intra-class correlation test and Wilcoxon test. Results Software achieved satisfied segmentation for 92.5% nodules. Of them, 35% underwent manual modification. The 95% limits of agreement for intra-observer variability were -11.5%-10.4% for mass and -8.4%-8.8% for volume. The 95% limits of agreement for inter-observer variability were -17.4%-19.3% for mass and -17.9%-19.4% for volume.The intra-class correlation foefficients between volume and mass measument was 0.95 and 0.93 (both P<0.001 and no significant differences (P=0.78, 0.09 was found for intra- and inter-observer variability. Manual modification of the segmentation caused the worse mass measurement repeatability in spite of the reader satisfaction. Conclusion The repeatability of mass measurement has no significant difference with that of volume measurement and may act as a reliable method in the follow-up of subsolid nodules.

  16. Statistical methodology for discrete fracture model - including fracture size, orientation uncertainty together with intensity uncertainty and variability

    Energy Technology Data Exchange (ETDEWEB)

    Darcel, C. (Itasca Consultants SAS (France)); Davy, P.; Le Goc, R.; Dreuzy, J.R. de; Bour, O. (Geosciences Rennes, UMR 6118 CNRS, Univ. def Rennes, Rennes (France))

    2009-11-15

    the lineament scale (k{sub t} = 2) on the other, addresses the issue of the nature of the transition. We develop a new 'mechanistic' model that could help in modeling why and where this transition can occur. The transition between both regimes would occur for a fracture length of 1-10 m and even at a smaller scale for the few outcrops that follow the self-similar density model. A consequence for the disposal issue is that the model that is likely to apply in the 'blind' scale window between 10-100 m is the self-similar model as it is defined for large-scale lineaments. The self-similar model, as it is measured for some outcrops and most lineament maps, is definitely worth being investigated as a reference for scales above 1-10 m. In the rest of the report, we develop a methodology for incorporating uncertainty and variability into the DFN modeling. Fracturing properties arise from complex processes which produce an intrinsic variability; characterizing this variability as an admissible variation of model parameter or as the division of the site into subdomains with distinct DFN models is a critical point of the modeling effort. Moreover, the DFN model encompasses a part of uncertainty, due to data inherent uncertainties and sampling limits. Both effects must be quantified and incorporated into the DFN site model definition process. In that context, all available borehole data including recording of fracture intercept positions, pole orientation and relative uncertainties are used as the basis for the methodological development and further site model assessment. An elementary dataset contains a set of discrete fracture intercepts from which a parent orientation/density distribution can be computed. The elementary bricks of the site, from which these initial parent density distributions are computed, rely on the former Single Hole Interpretation division of the boreholes into sections whose local boundaries are expected to reflect - locally - geology

  17. Intraobserver and interobserver variability in CT angiography and MR angiography measurements of the size of cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hye Jeong [Hallym University College of Medicine, Department of Radiology, Kangnam Sacred Heart Hospital, Seoul (Korea, Republic of); Yoon, Dae Young; Lee, Hyung Jin [Hallym University College of Medicine, Department of Radiology, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of); Kim, Eun Soo [Hallym University College of Medicine, Department of Radiology, Hallym University Sacred Heart Hospital, Anyang, Gyeonggi-do (Korea, Republic of); Jeon, Hong Jun; Lee, Jong Young; Cho, Byung-Moon [Hallym University College of Medicine, Department of Neurosurgery, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of)

    2017-05-15

    Accurate and reliable measurement of aneurysm size is important for treatment planning. The purpose of this study was to determine intraobserver and interobserver variability of CTA and MRA for measurement of the size of cerebral aneurysms. Thirty patients with 33 unruptured cerebral aneurysms (saccular, >3 mm in their maximal dimension, with no daughter sacs or lobulations) who underwent 256-row multislice CTA, 3-D TOF MRA at 3.0T, and 3D rotational angiography (3DRA) were retrospectively analyzed. Three independent observers measured the neck, height, and width of the aneurysms using the CTA and MRA images. Intraobserver and interobserver variability of CTA and MRA measurements was evaluated using the standardized difference and intraclass correlation coefficient, with 3DRA measurements as the reference standard. In addition, the mean values of the measurements using CTA and MRA were compared with those using 3DRA. The overall intraobserver and interobserver standardized differences in CTA/MRA were 12.83-15.92%/13.48-17.45% and 14.08-17.00%/12.08-17.67%, respectively. The overall intraobserver and interobserver intraclass correlation coefficients of CTA/MRA were 0.88-0.98/0.84-0.96 and 0.86-0.98/0.85-0.95, respectively. Compared to the height and width measurements, measurements of the neck dimensions showed higher intraobserver and interobserver variability. The sizes of the cerebral aneurysms measured by CTA and MRA were 1.13-9.26 and 5.20-9.67% larger than those measured by 3DRA, respectively; however, these differences were not statistically significant. There were no noticeable differences between intraobserver and interobserver variability for both CTA- and MRA-based measurements of the size of cerebral aneurysms. (orig.)

  18. Assessing the inter- and intra-animal variability of in vivo OsteoProbe skeletal measures in untreated dogs

    Directory of Open Access Journals (Sweden)

    Erin M.B. McNerny

    2016-12-01

    Full Text Available The OsteoProbe is a second-generation reference point indentation (RPI device without a reference probe that is designed to simplify RPI testing for clinical use. Successful clinical implementation of the OsteoProbe would benefit from a better understanding of how its output, bone material strength index (BMSi, relates to the material properties of bone and under what conditions it reliably correlates with fracture risk. Large animal models have the potential to help fill this knowledge gap, as cadaveric studies are retrospective and limited by incomplete patient histories (including the potential use of bone matrix altering drugs such as bisphosphonates. The goal of this study was to assess the intra and inter-animal variability of OsteoProbe measures in untreated beagle dogs (n = 12, and to evaluate this variability in comparison to traditional mechanical testing. OsteoProbe measurements were performed in vivo on the left tibia of each dog and repeated 6 months later on the day of sacrifice. Within-animal variation of BMSi (CV of 5–10 indents averaged 8.9 and 9.0% at the first and second timepoints, respectively. In contrast, inter-animal variation of BMSi increased from 5.3% to 9.1%. The group variation of BMSi was on par with that of traditional 3-point mechanical testing; inter-animal variation was 10% for ultimate force, 13% for stiffness, and 12% for total work as measured on the femur. There was no significant change in mean BMSi after 6 months, but the individual change with time across the 12 dogs was highly variable, ranging from −12.4% to +21.7% (mean 1.6%, SD 10.6%. No significant correlations were found between in vivo tibia BMSi and femur mechanical properties measured by ex vivo 3-pt bending, but this may be a limitation of sample size or the tests being performed on different bones. No relationship was found between BMSi and tissue mineral density, but a strong positive correlation was found between BMSi and tibia

  19. Estimation of intersubject variability of cerebral blood flow measurements using MRI and positron emission tomography

    DEFF Research Database (Denmark)

    Henriksen, Otto Mølby; Larsson, Henrik B W; Hansen, Adam E

    2012-01-01

    PURPOSE: To investigate the within and between subject variability of quantitative cerebral blood flow (CBF) measurements in normal subjects using various MRI techniques and positron emission tomography (PET). MATERIALS AND METHODS: Repeated CBF measurements were performed in 17 healthy, young...

  20. How novice, skilled and advanced clinical researchers include variables in a case report form for clinical research: a qualitative study.

    Science.gov (United States)

    Chu, Hongling; Zeng, Lin; Fetters, Micheal D; Li, Nan; Tao, Liyuan; Shi, Yanyan; Zhang, Hua; Wang, Xiaoxiao; Li, Fengwei; Zhao, Yiming

    2017-09-18

    Despite varying degrees in research training, most academic clinicians are expected to conduct clinical research. The objective of this research was to understand how clinical researchers of different skill levels include variables in a case report form for their clinical research. The setting for this research was a major academic institution in Beijing, China. The target population was clinical researchers with three levels of experience, namely, limited clinical research experience, clinicians with rich clinical research experience and clinical research experts. Using a qualitative approach, we conducted 13 individual interviews (face to face) and one group interview (n=4) with clinical researchers from June to September 2016. Based on maximum variation sampling to identify researchers with three levels of research experience: eight clinicians with limited clinical research experience, five clinicians with rich clinical research experience and four clinical research experts. These 17 researchers had diverse hospital-based medical specialties and or specialisation in clinical research. Our analysis yields a typology of three processes developing a case report form that varies according to research experience level. Novice clinician researchers often have an incomplete protocol or none at all, and conduct data collection and publication based on a general framework. Experienced clinician researchers include variables in the case report form based on previous experience with attention to including domains or items at risk for omission and by eliminating unnecessary variables. Expert researchers consider comprehensively in advance data collection and implementation needs and plan accordingly. These results illustrate increasing levels of sophistication in research planning that increase sophistication in selection for variables in the case report form. These findings suggest that novice and intermediate-level researchers could benefit by emulating the comprehensive

  1. Heart rate variability measured early in patients with evolving acute coronary syndrome and 1-year outcomes of rehospitalization and mortality

    Directory of Open Access Journals (Sweden)

    Harris PR

    2014-08-01

    Full Text Available Patricia R E Harris,1 Phyllis K Stein,2 Gordon L Fung,3 Barbara J Drew4 1Electrocardiographic Monitoring Research Laboratory, School of Nursing, Department of Physiological Nursing, University of California, San Francisco, CA, USA; 2Heart Rate Variability Laboratory, School of Medicine, Division of Cardiology, Washington University, St Louis, MO, USA; 3Cardiology Services, Mount Zion, Department of Medicine, Division of Cardiology, University of California, San Francisco, CA, USA; 4School of Nursing, Department of Physiological Nursing, Division of Cardiology, University of California, San Francisco, CA, USA Objective: This study sought to examine the prognostic value of heart rate variability (HRV measurement initiated immediately after emergency department presentation for patients with acute coronary syndrome (ACS. Background: Altered HRV has been associated with adverse outcomes in heart disease, but the value of HRV measured during the earliest phases of ACS related to risk of 1-year rehospitalization and death has not been established. Methods: Twenty-four-hour Holter recordings of 279 patients with ACS were initiated within 45 minutes of emergency department arrival; recordings with ≥18 hours of sinus rhythm were selected for HRV analysis (number [N] =193. Time domain, frequency domain, and nonlinear HRV were examined. Survival analysis was performed. Results: During the 1-year follow-up, 94 patients were event-free, 82 were readmitted, and 17 died. HRV was altered in relation to outcomes. Predictors of rehospitalization included increased normalized high frequency power, decreased normalized low frequency power, and decreased low/high frequency ratio. Normalized high frequency >42 ms2 predicted rehospitalization while controlling for clinical variables (hazard ratio [HR] =2.3; 95% confidence interval [CI] =1.4–3.8, P=0.001. Variables significantly associated with death included natural logs of total power and ultra low frequency

  2. Soil temperature variability in complex terrain measured using fiber-optic distributed temperature sensing

    Science.gov (United States)

    Soil temperature (Ts) exerts critical controls on hydrologic and biogeochemical processes but magnitude and nature of Ts variability in a landscape setting are rarely documented. Fiber optic distributed temperature sensing systems (FO-DTS) potentially measure Ts at high density over a large extent. ...

  3. Spatial Variability Analysis of Within-Field Winter Wheat Nitrogen and Grain Quality Using Canopy Fluorescence Sensor Measurements

    Directory of Open Access Journals (Sweden)

    Xiaoyu Song

    2017-03-01

    Full Text Available Wheat grain protein content (GPC is a key component when evaluating wheat nutrition. It is also important to determine wheat GPC before harvest for agricultural and food process enterprises in order to optimize the wheat grading process. Wheat GPC across a field is spatially variable due to the inherent variability of soil properties and position in the landscape. The objectives of this field study were: (i to assess the spatial and temporal variability of wheat nitrogen (N attributes related to the grain quality of winter wheat production through canopy fluorescence sensor measurements; and (ii to examine the influence of spatial variability of soil N and moisture across different growth stages on the wheat grain quality. A geostatistical approach was used to analyze data collected from 110 georeferenced locations. In particular, Ordinary Kriging Analysis (OKA was used to produce maps of wheat GPC, GPC yield, and wheat canopy fluorescence parameters, including simple florescence ratio and Nitrogen Balance Indices (NBI. Soil Nitrate-Nitrogen (NO3-N content and soil Time Domain Reflectometry (TDR value in the study field were also interpolated through the OKA method. The fluorescence parameter maps, soil NO3-N and soil TDR maps obtained from the OKA output were compared with the wheat GPC and GPC yield maps in order to assess their relationships. The results of this study indicate that the NBI spatial variability map in the late stage of wheat growth can be used to distinguish areas that produce higher GPC.

  4. Measurement of the ratio Γbb/Γhad using event shape variables

    Science.gov (United States)

    Buskulic, D.; de Bonis, I.; Decamp, D.; Ghez, P.; Goy, C.; Lees, J.-P.; Minard, M.-N.; Pietrzyk, B.; Ariztizabal, F.; Comas, P.; Crespo, J. M.; Delfino, M.; Efthymiopoulos, I.; Fernandez, E.; Fernandez-Bosman, M.; Gaitan, V.; Garrido, Ll.; Mattison, T.; Pacheco, A.; Padilla, C.; Pascual, A.; Creanza, D.; de Palma, M.; Farilla, A.; Iaselli, G.; Maggi, G.; Natali, S.; Nuzzo, S.; Quattromini, M.; Ranieri, A.; Raso, G.; Romano, F.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Zito, G.; Chai, Y.; Hu, H.; Huang, D.; Huang, X.; Lin, J.; Wang, T.; Xie, Y.; Xie, D.; Xu, D.; Xu, R.; Zhang, J.; Zhang, L.; Zhao, W.; Blucher, E.; Bonvicini, G.; Boudreau, J.; Casper, D.; Drevermann, H.; Forty, R. W.; Ganis, G.; Gay, C.; Hagelberg, R.; Harvey, J.; Hilgart, J.; Jacobsen, R.; Jost, B.; Knobloch, J.; Lehraus, I.; Lohse, T.; Maggi, M.; Markou, C.; Martinez, M.; Mato, P.; Meinhard, H.; Minten, A.; Miotto, A.; Miquel, R.; Moser, H.-G.; Palazzi, P.; Pater, J. R.; Perlas, J. A.; Pusztaszeri, J.-F.; Ranjard, F.; Redlinger, G.; Rolandi, L.; Rothberg, J.; Ruan, T.; Saich, M.; Schlatter, D.; Schmelling, M.; Sefkow, F.; Tejessy, W.; Tomalin, I. R.; Veenhof, R.; Wachsmuth, H.; Wasserbaech, S.; Wiedenmann, W.; Wildish, T.; Witzeling, W.; Wotschack, J.; Ajaltouni, Z.; Badaud, F.; Bardadin-Otwinowska, M.; El Fellous, R.; Falvard, A.; Gay, P.; Guicheney, C.; Henrard, P.; Jousset, J.; Michel, B.; Montret, J.-C.; Pallin, D.; Perret, P.; Podlyski, F.; Proriol, J.; Prulhière, F.; Saadi, F.; Fearnley, T.; Hansen, J. B.; Hansen, J. D.; Hansen, J. R.; Hansen, P. H.; Møllerud, R.; Nilsson, B. S.; Kyriakis, A.; Simopoulou, E.; Siotis, I.; Vayaki, A.; Zachariadou, K.; Badier, J.; Blondel, A.; Bonneaud, G.; Brient, J. C.; Fouque, G.; Orteu, S.; Rougé, A.; Rumpf, M.; Tanaka, R.; Verderi, M.; Videau, H.; Candlin, D. J.; Parsons, M. I.; Veitch, E.; Focardi, E.; Moneta, L.; Parrini, G.; Corden, M.; Georgiopoulos, C.; Ikeda, M.; Levinthal, D.; Antonelli, A.; Baldini, R.; Bencivenni, G.; Bologna, G.; Bossi, F.; Campana, P.; Capon, G.; Cerutti, F.; Chiarella, V.; D'Ettorre-Piazzoli, B.; Felici, G.; Laurelli, P.; Mannocchi, G.; Murtas, F.; Murtas, G. P.; Passalacqua, L.; Pepe-Altarelli, M.; Picchi, P.; Colrain, P.; Ten Have, I.; Lynch, J. G.; Maitland, W.; Morton, W. T.; Raine, C.; Reeves, P.; Scarr, J. M.; Smith, K.; Smith, M. G.; Thompson, A. S.; Turnbull, R. M.; Brandl, B.; Braun, O.; Geweniger, C.; Hanke, P.; Hepp, V.; Kluge, E. E.; Maumary, Y.; Putzer, A.; Rensch, B.; Stahl, A.; Tittel, K.; Wunsch, M.; Beuselinck, R.; Binnie, D. M.; Cameron, W.; Cattaneo, M.; Colling, D. J.; Dornan, P. J.; Greene, A. M.; Hassard, J. F.; Lieske, N. M.; Moutoussi, A.; Nash, J.; Patton, S.; Payne, D. G.; Phillips, M. J.; San Martin, G.; Sedgbeer, J. K.; Wright, A. G.; Girtler, P.; Kuhn, D.; Rudolph, G.; Vogl, R.; Bowdery, C. K.; Brodbeck, T. J.; Finch, A. J.; Foster, F.; Hughes, G.; Jackson, D.; Keemer, N. R.; Nuttall, M.; Patel, A.; Sloan, T.; Snow, S. W.; Whelan, E. P.; Kleinknecht, K.; Raab, J.; Renk, B.; Sander, H.-G.; Schmidt, H.; Steeg, F.; Walther, S. M.; Wanke, R.; Wolf, B.; Bencheikh, A. M.; Benchouk, C.; Bonissent, A.; Carr, J.; Coyle, P.; Drinkard, J.; Etienne, F.; Nicod, D.; Papalexiou, S.; Payre, P.; Roos, L.; Rousseau, D.; Schwemling, P.; Talby, M.; Adlung, S.; Assmann, R.; Bauer, C.; Blum, W.; Brown, D.; Cattaneo, P.; Dehning, B.; Dietl, H.; Dydak, F.; Frank, M.; Halley, A. W.; Jakobs, K.; Lauber, J.; Lütjens, G.; Lutz, G.; Männer, W.; Richter, R.; Schröder, J.; Schwarz, A. S.; Settles, R.; Seywerd, H.; Stierlin, U.; Stiegler, U.; St. Denis, R.; Wolf, G.; Alemany, R.; Boucrot, J.; Callot, O.; Cordier, A.; Davier, M.; Duflot, L.; Grivaz, J.-F.; Heusse, Ph.; Jaffe, D. E.; Janot, P.; Kim, D. W.; Le Diberder, F.; Lefrançois, J.; Lutz, A.-M.; Schune, M.-H.; Veillet, J.-J.; Videau, I.; Zhang, Z.; Abbaneo, D.; Bagliesi, G.; Batignani, G.; Bottigli, U.; Bozzi, C.; Calderini, G.; Carpinelli, M.; Ciocci, M. A.; dell'Orso, R.; Ferrante, I.; Fidecaro, F.; Foà, L.; Forti, F.; Giassi, A.; Giorgi, M. A.; Gregorio, A.; Ligabue, F.; Lusiani, A.; Mannelli, E. B.; Marrocchesi, P. S.; Messineo, A.; Palla, F.; Rizzo, G.; Sanguinetti, G.; Spagnolo, P.; Steinberger, J.; Tenchini, R.; Tonelli, G.; Triggiani, G.; Vannini, C.; Venturi, A.; Verdini, P. G.; Walsh, J.; Betteridge, A. P.; Gao, Y.; Green, M. G.; March, P. V.; Mir, Ll. M.; Medcalf, T.; Quazi, I. S.; Strong, J. A.; West, L. R.; Botterill, D. R.; Clifft, R. W.; Edgecock, T. R.; Haywood, S.; Norton, P. R.; Thompson, J. C.; Bloch-Devaux, B.; Colas, P.; Duarte, H.; Emery, S.; Kozanecki, W.; Lançon, E.; Lemaire, M. C.; Locci, E.; Marx, B.; Perez, P.; Rander, J.; Renardy, J.-F.; Rosowsky, A.; Roussarie, A.; Schuller, J.-P.; Schwindling, J.; Si Mohand, D.; Vallage, B.; Johnson, R. P.; Litke, A. M.; Taylor, G.; Wear, J.; Ashman, J. G.; Babbage, W.; Booth, C. N.; Buttar, C.; Cartwright, S.; Combley, F.; Dawson, I.; Thompson, L. F.; Barberio, E.; Böhrer, A.; Brandt, S.; Cowan, G.; Grupen, C.; Lutters, G.; Rivera, F.; Schäfer, U.; Smolik, L.; Bosisio, L.; della Marina, R.; Giannini, G.; Gobbo, B.; Ragusa, F.; Bellantoni, L.; Chen, W.; Conway, J. S.; Feng, Z.; Ferguson, D. P. S.; Gao, Y. S.; Grahl, J.; Harton, J. L.; Hayes, O. J.; Nachtman, J. M.; Pan, Y. B.; Saadi, Y.; Schmitt, M.; Scott, I.; Sharma, V.; Shi, Z. H.; Turk, J. D.; Walsh, A. M.; Weber, F. V.; Lan Wu, Sau; Wu, X.; Zheng, M.; Zobernig, G.

    1993-09-01

    The branching fraction of Z --> bb relative to all hadronic decays of the Z has been measured using event shape variables to preferentially select Z --> bb events. The method chosen applies a combination of shape discriminators and the selection of high transverse momentum leptons to event hemispheres. From a sample of 440 000 hadronic Z decays collected with the ALEPH detector at LEP, the ration Γbb/Γhad = 0.228+/-0.005(stat.)+/-0.005(syst.) is measured. Supported by the US Department of Energy, contract DE-AC02-76ER00881.

  5. Persistent pulmonary subsolid nodules: model-based iterative reconstruction for nodule classification and measurement variability on low-dose CT.

    Science.gov (United States)

    Kim, Hyungjin; Park, Chang Min; Kim, Seong Ho; Lee, Sang Min; Park, Sang Joon; Lee, Kyung Hee; Goo, Jin Mo

    2014-11-01

    To compare the pulmonary subsolid nodule (SSN) classification agreement and measurement variability between filtered back projection (FBP) and model-based iterative reconstruction (MBIR). Low-dose CTs were reconstructed using FBP and MBIR for 47 patients with 47 SSNs. Two readers independently classified SSNs into pure or part-solid ground-glass nodules, and measured the size of the whole nodule and solid portion twice on both reconstruction algorithms. Nodule classification agreement was analyzed using Cohen's kappa and compared between reconstruction algorithms using McNemar's test. Measurement variability was investigated using Bland-Altman analysis and compared with the paired t-test. Cohen's kappa for inter-reader SSN classification agreement was 0.541-0.662 on FBP and 0.778-0.866 on MBIR. Between the two readers, nodule classification was consistent in 79.8 % (75/94) with FBP and 91.5 % (86/94) with MBIR (p = 0.027). Inter-reader measurement variability range was -5.0-2.1 mm on FBP and -3.3-1.8 mm on MBIR for whole nodule size, and was -6.5-0.9 mm on FBP and -5.5-1.5 mm on MBIR for solid portion size. Inter-reader measurement differences were significantly smaller on MBIR (p = 0.027, whole nodule; p = 0.011, solid portion). MBIR significantly improved SSN classification agreement and reduced measurement variability of both whole nodules and solid portions between readers. • Low-dose CT using MBIR algorithm improves reproducibility in the classification of SSNs. • MBIR would enable more confident clinical planning according to the SSN type. • Reduced measurement variability on MBIR allows earlier detection of potentially malignant nodules.

  6. Modeling intraindividual variability with repeated measures data methods and applications

    CERN Document Server

    Hershberger, Scott L

    2013-01-01

    This book examines how individuals behave across time and to what degree that behavior changes, fluctuates, or remains stable.It features the most current methods on modeling repeated measures data as reported by a distinguished group of experts in the field. The goal is to make the latest techniques used to assess intraindividual variability accessible to a wide range of researchers. Each chapter is written in a ""user-friendly"" style such that even the ""novice"" data analyst can easily apply the techniques.Each chapter features:a minimum discussion of mathematical detail;an empirical examp

  7. Intra- and inter-observer variability and accuracy in the determination of linear and angular measurements in computed tomography

    International Nuclear Information System (INIS)

    Christiansen, E.L.; Thompson, J.R.; Kopp, S.

    1986-01-01

    The observer variability and accuracy of linear and angular computed tomography (CT) software measurements in the transaxial plane were investigated for the temporomandibular joint with the General Electric 8800 CT/N Scanner. A dried and measured human mandible was embedded in plastic and scanned in vitro. Sixteen observers participated in the study. The following measurements were tested: inter- and extra-condylar distances, transverse condylar dimension, condylar angulation, and the plastic base of the specimen. Three frozen cadaveric heads were similarly scanned and measured in situ. Intra- and inter-observer variabilities were lowest for the specimen base and highest for condylar angulation. Neuroradiologists had the lowest variability as a group, and the radiology residents and paramedical personell had the highest, but the differences were small. No significant difference was found between CT and macroscopic measurement of the mandible. In situ measurement by CT of condyles with structural changes in the transaxial plane was, however, subject to substantial error. It was concluded that transaxial linear measurements of the condylar processes free of significant structural changes had an error and an accuracy well within acceptable limits. The error for angular measurements was significantly greater than the error for linear measurements

  8. The effects of metronome breathing on the variability of autonomic activity measurements.

    Science.gov (United States)

    Driscoll, D; Dicicco, G

    2000-01-01

    Many chiropractors hypothesize that spinal manipulation affects the autonomic nervous system (ANS). However, the ANS responses to chiropractic manipulative therapy are not well documented, and more research is needed to support this hypothesis. This study represents a step toward the development of a reliable method by which to document that chiropractic manipulative therapy does affect the ANS by exploring the use of paced breathing as a way to reduce the inherent variability in ANS measurements. To examine the hypothesis that the variability of ANS measurements would be reduced if breathing were paced to a metronome at 12 breaths/min. The study was performed at Parker College Research Institute. Eight normotensive subjects were recruited from the student body and staff. Respiration frequency was measured through a strain gauge. A 3-lead electrocardiogram (ECG) was used to register the electric activity of the heart, and arterial tonometry monitors were used to record the left and right radial artery blood pressures. Signals were recorded on an IBM-compatible computer with a sampling frequency of 100 Hz. Normal breathing was used for the first 3 recordings, and breathing was paced to a metronome for the final 3 recordings at 12 breaths/min. Fourier analysis was performed on the beat-by-beat fluctuations of the ECG-determined R-R interval and systolic arterial pressure (SBP). Low-frequency fluctuations (LF; 0.04-0.15 Hz) reflected sympathetic activity, whereas high-frequency fluctuations (HF; 0.15-0.4 Hz) represented parasympathetic activity. Sympathovagal indices were determined from the ratio of the two bandwidths (LF/HF). The coefficient of variation (CV%) for autonomic parameters was calculated ([average/SD] x 100%) to compare breathing normally and breathing to a metronome with respect to variability. One-way analysis of variance was used to detect differences. A value of P Metronome breathing did not produce any significant changes in blood pressure for the

  9. Changes in heart rate variability and QT variability during the first trimester of pregnancy.

    Science.gov (United States)

    Carpenter, R E; D'Silva, L A; Emery, S J; Uzun, O; Rassi, D; Lewis, M J

    2015-03-01

    The risk of new-onset arrhythmia during pregnancy is high, presumably relating to changes in both haemodynamic and cardiac autonomic function. The ability to non-invasively assess an individual's risk of developing arrhythmia during pregnancy would therefore be clinically significant. We aimed to quantify electrocardiographic temporal characteristics during the first trimester of pregnancy and to compare these with non-pregnant controls. Ninety-nine pregnant women and sixty-three non-pregnant women underwent non-invasive cardiovascular and haemodynamic assessment during a protocol consisting of various physiological states (postural manoeurvres, light exercise and metronomic breathing). Variables measured included stroke volume, cardiac output, heart rate, heart rate variability, QT and QT variability and QTVI (a measure of the variability of QT relative to that of RR). Heart rate (p pregnancy only during the supine position (p pregnancy in all physiological states (p pregnancy in all states (p pregnancy is associated with substantial changes in heart rate variability, reflecting a reduction in parasympathetic tone and an increase in sympathetic activity. QTVI shifted to a less favourable value, reflecting a greater than normal amount of QT variability. QTVI appears to be a useful method for quantifying changes in QT variability relative to RR (or heart rate) variability, being sensitive not only to physiological state but also to gestational age. We support the use of non-invasive markers of cardiac electrical variability to evaluate the risk of arrhythmic events in pregnancy, and we recommend the use of multiple physiological states during the assessment protocol.

  10. Measurement Uncertainty in Racial and Ethnic Identification among Adolescents of Mixed Ancestry: A Latent Variable Approach

    Science.gov (United States)

    Tracy, Allison J.; Erkut, Sumru; Porche, Michelle V.; Kim, Jo; Charmaraman, Linda; Grossman, Jennifer M.; Ceder, Ineke; Garcia, Heidie Vazquez

    2010-01-01

    In this article, we operationalize identification of mixed racial and ethnic ancestry among adolescents as a latent variable to (a) account for measurement uncertainty, and (b) compare alternative wording formats for racial and ethnic self-categorization in surveys. Two latent variable models were fit to multiple mixed-ancestry indicator data from…

  11. Measuring myokines with cardiovascular functions: pre-analytical variables affecting the analytical output.

    Science.gov (United States)

    Lombardi, Giovanni; Sansoni, Veronica; Banfi, Giuseppe

    2017-08-01

    In the last few years, a growing number of molecules have been associated to an endocrine function of the skeletal muscle. Circulating myokine levels, in turn, have been associated with several pathophysiological conditions including the cardiovascular ones. However, data from different studies are often not completely comparable or even discordant. This would be due, at least in part, to the whole set of situations related to the preparation of the patient prior to blood sampling, blood sampling procedure, processing and/or store. This entire process constitutes the pre-analytical phase. The importance of the pre-analytical phase is often not considered. However, in routine diagnostics, the 70% of the errors are in this phase. Moreover, errors during the pre-analytical phase are carried over in the analytical phase and affects the final output. In research, for example, when samples are collected over a long time and by different laboratories, a standardized procedure for sample collecting and the correct procedure for sample storage are acknowledged. In this review, we discuss the pre-analytical variables potentially affecting the measurement of myokines with cardiovascular functions.

  12. Violation of Continuous-Variable Einstein-Podolsky-Rosen Steering with Discrete Measurements

    Science.gov (United States)

    Schneeloch, James; Dixon, P. Ben; Howland, Gregory A.; Broadbent, Curtis J.; Howell, John C.

    2013-03-01

    In this Letter, we derive an entropic Einstein-Podolsky-Rosen (EPR) steering inequality for continuous-variable systems using only experimentally measured discrete probability distributions and details of the measurement apparatus. We use this inequality to witness EPR steering between the positions and momenta of photon pairs generated in spontaneous parametric down-conversion. We examine the asymmetry between parties in this inequality, and show that this asymmetry can be used to reduce the technical requirements of experimental setups intended to demonstrate the EPR paradox. Furthermore, we develop a more stringent steering inequality that is symmetric between parties, and use it to show that the down-converted photon pairs also exhibit symmetric EPR steering.

  13. Modelling modulus of elasticity of Pinus pinaster Ait. in northwestern Spain with standing tree acoustic measurements, tree, stand and site variables

    Directory of Open Access Journals (Sweden)

    Esther Merlo

    2014-04-01

    Full Text Available Aim of study: Modelling the structural quality of Pinus pinaster Ait. wood on the basis of measurements made on standing trees is essential because of the importance of the species in the Galician forestry and timber industries and the good mechanical properties of its wood. In this study, we investigated how timber stiffness is affected by tree and stand properties, climatic and edaphic characteristics and competition. Area of study: The study was performed in Galicia, north-western Spain.Material and methods: Ten pure and even-aged P. pinaster stands were selected and tree and stand variables and the stress wave velocity of 410 standing trees were measured. A sub-sample of 73 trees, representing the variability in acoustic velocity, were felled and sawed into structural timber pieces (224 which were subjected to a bending test to determine the modulus of elasticity (MOE. Main results: Linear models including wood properties explained more than 97%, 73% and 60% of the observed MOE variability at site, tree and board level, respectively, with acoustic velocity and wood density as the main regressors. Other linear models, which did not include wood density, explained more than 88%, 69% and 55% of the observed MOE variability at site, tree and board level, respectively, with acoustic velocity as the main regressor. Moreover, a classification tree for estimating the visual grade according to standard UNE 56544:2011 was developed. Research highlights: The results have demonstrated the usefulness of acoustic velocity for predicting MOE in standing trees. The use of the fitted equations together with existing dynamic growth models will enable preliminary assessment of timber stiffness in relation to different silvicultural alternatives used with this species.Keywords: stress wave velocity, modulus of elasticity, site index, competition index, stepwise regression, CART.

  14. Quantitative Assessment of Blood Pressure Measurement Accuracy and Variability from Visual Auscultation Method by Observers without Receiving Medical Training

    Science.gov (United States)

    Feng, Yong; Chen, Aiqing

    2017-01-01

    This study aimed to quantify blood pressure (BP) measurement accuracy and variability with different techniques. Thirty video clips of BP recordings from the BHS training database were converted to Korotkoff sound waveforms. Ten observers without receiving medical training were asked to determine BPs using (a) traditional manual auscultatory method and (b) visual auscultation method by visualizing the Korotkoff sound waveform, which was repeated three times on different days. The measurement error was calculated against the reference answers, and the measurement variability was calculated from the SD of the three repeats. Statistical analysis showed that, in comparison with the auscultatory method, visual method significantly reduced overall variability from 2.2 to 1.1 mmHg for SBP and from 1.9 to 0.9 mmHg for DBP (both p auscultation methods). In conclusion, the visual auscultation method had the ability to achieve an acceptable degree of BP measurement accuracy, with smaller variability in comparison with the traditional auscultatory method. PMID:29423405

  15. Variability of bronchial measurements obtained by sequential CT using two computer-based methods

    International Nuclear Information System (INIS)

    Brillet, Pierre-Yves; Fetita, Catalin I.; Mitrea, Mihai; Preteux, Francoise; Capderou, Andre; Dreuil, Serge; Simon, Jean-Marc; Grenier, Philippe A.

    2009-01-01

    This study aimed to evaluate the variability of lumen (LA) and wall area (WA) measurements obtained on two successive MDCT acquisitions using energy-driven contour estimation (EDCE) and full width at half maximum (FWHM) approaches. Both methods were applied to a database of segmental and subsegmental bronchi with LA > 4 mm 2 containing 42 bronchial segments of 10 successive slices that best matched on each acquisition. For both methods, the 95% confidence interval between repeated MDCT was between -1.59 and 1.5 mm 2 for LA, and -3.31 and 2.96 mm 2 for WA. The values of the coefficient of measurement variation (CV 10 , i.e., percentage ratio of the standard deviation obtained from the 10 successive slices to their mean value) were strongly correlated between repeated MDCT data acquisitions (r > 0.72; p 2 , whereas WA values were lower for bronchi with WA 2 ; no systematic EDCE underestimation or overestimation was observed for thicker-walled bronchi. In conclusion, variability between CT examinations and assessment techniques may impair measurements. Therefore, new parameters such as CV 10 need to be investigated to study bronchial remodeling. Finally, EDCE and FWHM are not interchangeable in longitudinal studies. (orig.)

  16. Persistent pulmonary subsolid nodules: model-based iterative reconstruction for nodule classification and measurement variability on low-dose CT

    International Nuclear Information System (INIS)

    Kim, Hyungjin; Kim, Seong Ho; Lee, Sang Min; Lee, Kyung Hee; Park, Chang Min; Park, Sang Joon; Goo, Jin Mo

    2014-01-01

    To compare the pulmonary subsolid nodule (SSN) classification agreement and measurement variability between filtered back projection (FBP) and model-based iterative reconstruction (MBIR). Low-dose CTs were reconstructed using FBP and MBIR for 47 patients with 47 SSNs. Two readers independently classified SSNs into pure or part-solid ground-glass nodules, and measured the size of the whole nodule and solid portion twice on both reconstruction algorithms. Nodule classification agreement was analyzed using Cohen's kappa and compared between reconstruction algorithms using McNemar's test. Measurement variability was investigated using Bland-Altman analysis and compared with the paired t-test. Cohen's kappa for inter-reader SSN classification agreement was 0.541-0.662 on FBP and 0.778-0.866 on MBIR. Between the two readers, nodule classification was consistent in 79.8 % (75/94) with FBP and 91.5 % (86/94) with MBIR (p = 0.027). Inter-reader measurement variability range was -5.0-2.1 mm on FBP and -3.3-1.8 mm on MBIR for whole nodule size, and was -6.5-0.9 mm on FBP and -5.5-1.5 mm on MBIR for solid portion size. Inter-reader measurement differences were significantly smaller on MBIR (p = 0.027, whole nodule; p = 0.011, solid portion). MBIR significantly improved SSN classification agreement and reduced measurement variability of both whole nodules and solid portions between readers. (orig.)

  17. Attention Measures of Accuracy, Variability, and Fatigue Detect Early Response to Donepezil in Alzheimer's Disease: A Randomized, Double-blind, Placebo-Controlled Pilot Trial.

    Science.gov (United States)

    Vila-Castelar, Clara; Ly, Jenny J; Kaplan, Lillian; Van Dyk, Kathleen; Berger, Jeffrey T; Macina, Lucy O; Stewart, Jennifer L; Foldi, Nancy S

    2018-04-09

    Donepezil is widely used to treat Alzheimer's disease (AD), but detecting early response remains challenging for clinicians. Acetylcholine is known to directly modulate attention, particularly under high cognitive conditions, but no studies to date test whether measures of attention under high load can detect early effects of donepezil. We hypothesized that load-dependent attention tasks are sensitive to short-term treatment effects of donepezil, while global and other domain-specific cognitive measures are not. This longitudinal, randomized, double-blind, placebo-controlled pilot trial (ClinicalTrials.gov Identifier: NCT03073876) evaluated 23 participants newly diagnosed with AD initiating de novo donepezil treatment (5 mg). After baseline assessment, participants were randomized into Drug (n = 12) or Placebo (n = 11) groups, and retested after approximately 6 weeks. Cognitive assessment included: (a) attention tasks (Foreperiod Effect, Attentional Blink, and Covert Orienting tasks) measuring processing speed, top-down accuracy, orienting, intra-individual variability, and fatigue; (b) global measures (Alzheimer's Disease Assessment Scale-Cognitive Subscale, Mini-Mental Status Examination, Dementia Rating Scale); and (c) domain-specific measures (memory, language, visuospatial, and executive function). The Drug but not the Placebo group showed benefits of treatment at high-load measures by preserving top-down accuracy, improving intra-individual variability, and averting fatigue. In contrast, other global or cognitive domain-specific measures could not detect treatment effects over the same treatment interval. The pilot-study suggests that attention measures targeting accuracy, variability, and fatigue under high-load conditions could be sensitive to short-term cholinergic treatment. Given the central role of acetylcholine in attentional function, load-dependent attentional measures may be valuable cognitive markers of early treatment response.

  18. Endotracheal temperature and humidity measurements in laryngectomized patients: intra- and inter-patient variability

    NARCIS (Netherlands)

    Scheenstra, R.J.; Muller, S.H.; Vincent, A.; Sinaasappel, M.; Zuur, J.K.; Hilgers, F.J.M.

    2009-01-01

    This study assesses intra- and inter-patient variability in endotracheal climate (temperature and humidity) and effects of heat and moister exchangers (HME) in 16 laryngectomized individuals, measured repeatedly (N = 47). Inhalation Breath Length (IBL) was 1.35 s without HME and 1.05 s with HME (P <

  19. Endotracheal temperature and humidity measurements in laryngectomized patients: intra- and inter-patient variability

    NARCIS (Netherlands)

    Scheenstra, R. J.; Muller, S. H.; Vincent, A.; Sinaasappel, M.; Zuur, J. K.; Hilgers, Frans J. M.

    2009-01-01

    This study assesses intra- and inter-patient variability in endotracheal climate (temperature and humidity) and effects of heat and moister exchangers (HME) in 16 laryngectomized individuals, measured repeatedly (N = 47). Inhalation Breath Length (IBL) was 1.35 s without HME and 1.05 s with HME (P

  20. Lexical and phonological variability in preschool children with speech sound disorder.

    Science.gov (United States)

    Macrae, Toby; Tyler, Ann A; Lewis, Kerry E

    2014-02-01

    The authors of this study examined relationships between measures of word and speech error variability and between these and other speech and language measures in preschool children with speech sound disorder (SSD). In this correlational study, 18 preschool children with SSD, age-appropriate receptive vocabulary, and normal oral motor functioning and hearing were assessed across 2 sessions. Experimental measures included word and speech error variability, receptive vocabulary, nonword repetition (NWR), and expressive language. Pearson product–moment correlation coefficients were calculated among the experimental measures. The correlation between word and speech error variability was slight and nonsignificant. The correlation between word variability and receptive vocabulary was moderate and negative, although nonsignificant. High word variability was associated with small receptive vocabularies. The correlations between speech error variability and NWR and between speech error variability and the mean length of children's utterances were moderate and negative, although both were nonsignificant. High speech error variability was associated with poor NWR and language scores. High word variability may reflect unstable lexical representations, whereas high speech error variability may reflect indistinct phonological representations. Preschool children with SSD who show abnormally high levels of different types of speech variability may require slightly different approaches to intervention.

  1. Momentum, sensible heat and CO2 correlation coefficient variability: what can we learn from 20 years of continuous eddy covariance measurements?

    Science.gov (United States)

    Hurdebise, Quentin; Heinesch, Bernard; De Ligne, Anne; Vincke, Caroline; Aubinet, Marc

    2017-04-01

    Long-term data series of carbon dioxide and other gas exchanges between terrestrial ecosystems and atmosphere become more and more numerous. Long-term analyses of such exchanges require a good understanding of measurement conditions during the investigated period. Independently of climate drivers, measurements may indeed be influenced by measurement conditions themselves subjected to long-term variability due to vegetation growth or set-up changes. The present research refers to the Vielsalm Terrestrial Observatory (VTO) an ICOS candidate site located in a mixed forest (beech, silver fir, Douglas fir, Norway spruce) in the Belgian Ardenne. Fluxes of momentum, carbon dioxide and sensible heat have been continuously measured there by eddy covariance for more than 20 years. During this period, changes in canopy height and measurement height occurred. The correlation coefficients (for momemtum, sensible heat and CO2) and the normalized standard deviations measured for the past 20 years at the Vielsalm Terrestrial Observatory (VTO) were analysed in order to define how the fluxes, independently of climate conditions, were affected by the surrounding environment evolution, including tree growth, forest thinning and tower height change. A relationship between canopy aerodynamic distance and the momentum correlation coefficient was found which is characteristic of the roughness sublayer, and suggests that momentum transport processes were affected by z-d. In contrast, no relationship was found for sensible heat and CO2 correlation coefficients, suggesting that the z-d variability observed did not affect their turbulent transport. There were strong differences in these coefficients, however, between two wind sectors, characterized by contrasted stands (height differences, homogeneity) and different hypotheses were raised to explain it. This study highlighted the importance of taking the surrounding environment variability into account in order to ensure the spatio

  2. Effects of weight loss diet therapy on anthropometric measurements and biochemical variables in schizophrenic patients.

    Science.gov (United States)

    Urhan, Murat; Ergün, Can; Aksoy, Meral; Ayer, Ahmet

    2015-07-01

    Prevalence of obesity in schizophrenic patients is two to three times higher than in the general population and unhealthy dietary patterns, a sedentary lifestyle and antipsychotic medication use may contribute to the higher levels of obesity among schizophrenic patients. We evaluated the effects of diet therapy on weight loss, anthropometric and biochemical variables in overweight or obese (body mass index, BMI ≥ 27 kg/m(2)) female schizophrenic patients who use antipsychotic medications and in healthy volunteers. Primary demographic variables were collected via questionnaire; blood samples and anthropometric measurements were obtained. Personalized diet recipes were prepared and nutritional education was shared. We logged the physical activity of the patients and maintained food consumption records at 3-day intervals. Participants were weighed every week; anthropometric measurements and blood samples were collected at the end of the first and second months. At the end of the study, reductions in body weight and other anthropometric measurements were statistically significant (P < 0.05). Reductions in body weight and BMI values for patient group were - 4.05 ± 1.73 kg and - 1.62 ± 0.73 kg/m(2) and for the control group were - 6.79 ± 1.80 kg and - 2.55 ± 0.64 kg/m(2), respectively. When compared with the patient group, reductions in the anthropometric variables of the control group were statistically significant (P < 0.05). Fasting glucose, blood lipids, albumin and leptin levels were decreased; insulin and homeostatic model assessment-measured insulin resistance (HOMA-IR) levels were increased insignificantly. Increases in the blood ghrelin levels for both groups were statistically significant (P < 0.05). Improvements to the diets of schizophrenic patient led to improvements in anthropometric measurements and biochemical variables and reduced the health risks caused by antipsychotic medications. Furthermore, we hypothesize that antipsychotic medications do not

  3. Gait variability measurements in lumbar spinal stenosis patients: part A. Comparison with healthy subjects

    International Nuclear Information System (INIS)

    Papadakis, N C; Christakis, D G; Tzagarakis, G N; Chlouverakis, G I; Kampanis, N A; Stergiopoulos, K N; Katonis, P G

    2009-01-01

    The objective of this study is to compare the gait variability of patients with lumbar spinal stenosis (experimental group) with healthy individuals (control group). The hypothesis is that the preoperative gait variability of the experimental group is higher than the control group. The experimental group consisted of 35 adults (18 males, 17 females). The subjects of the experimental group suffered exclusively from spinal stenosis. The patients were determined by MRI scans. A tri-axial accelerometer sensor was used for the gait measurement, and differential entropy algorithm was used to quantify the gait acceleration signal. The Oswestry Low Back Pain Questionnaire was used to determine the condition on the day of the measurement. Receiver operating characteristic (ROC) was utilized to assess the diagnostic value of the method and determine a cut-off value. There is a statistically significant difference between gait variability in the control group and the experimental group. ROC analysis determines a cut-off differential entropy value. The cut-off value has a 97.6% probability of separating patients with spinal stenosis from healthy subjects. The Oswestry Low Back Questionnaire is well correlated with the spectral differential entropy values

  4. Challenge in Enhancing the Teaching and Learning of Variable Measurements in Quantitative Research

    Science.gov (United States)

    Kee, Chang Peng; Osman, Kamisah; Ahmad, Fauziah

    2013-01-01

    Statistical analysis is one component that cannot be avoided in a quantitative research. Initial observations noted that students in higher education institution faced difficulty analysing quantitative data which were attributed to the confusions of various variable measurements. This paper aims to compare the outcomes of two approaches applied in…

  5. Remote sensing of Essential Biodiversity Variables: new measurements linking ecosystem structure, function and composition

    Science.gov (United States)

    Schimel, D.; Pavlick, R.; Stavros, E. N.; Townsend, P. A.; Ustin, S.; Thompson, D. R.

    2017-12-01

    Remote sensing can inform a wide variety of essential biodiversity variables, including measurements that define primary productivity, forest structure, biome distribution, plant communities, land use-land cover change and climate drivers of change. Emerging remote sensing technologies can add significantly to remote sensing of EBVs, providing new, large scale insights on plant and habitat diversity itself, as well as causes and consequences of biodiversity change. All current biodiversity assessments identify major data gaps, with insufficient coverage in critical regions, limited observations to monitor change over time, with very limited revisit of sample locations, as well as taxon-specific biased biases. Remote sensing cannot fill many of the gaps in global biodiversity observations, but spectroscopic measurements in terrestrial and marine environments can aid in assessing plant/phytoplankton functional diversity and efficiently reveal patterns in space, as well as changes over time, and, by making use of chlorophyll fluorescence, reveal associated patterns in photosynthesis. LIDAR and RADAR measurements quantify ecosystem structure, and can precisely define changes due to growth, disturbance and land use. Current satellite-based EBVs have taken advantage of the extraordinary time series from LANDSAT and MODIS, but new measurements more directly reveal ecosystem structure, function and composition. We will present results from pre-space airborne studies showing the synergistic ability of a suite of new remote observation techniques to quantify biodiversity and ecosystem function and show how it changes during major disturbance events.

  6. Conventional QT Variability Measurement vs. Template Matching Techniques: Comparison of Performance Using Simulated and Real ECG

    Science.gov (United States)

    Baumert, Mathias; Starc, Vito; Porta, Alberto

    2012-01-01

    Increased beat-to-beat variability in the QT interval (QTV) of ECG has been associated with increased risk for sudden cardiac death, but its measurement is technically challenging and currently not standardized. The aim of this study was to investigate the performance of commonly used beat-to-beat QT interval measurement algorithms. Three different methods (conventional, template stretching and template time shifting) were subjected to simulated data featuring typical ECG recording issues (broadband noise, baseline wander, amplitude modulation) and real short-term ECG of patients before and after infusion of sotalol, a QT interval prolonging drug. Among the three algorithms, the conventional algorithm was most susceptible to noise whereas the template time shifting algorithm showed superior overall performance on simulated and real ECG. None of the algorithms was able to detect increased beat-to-beat QT interval variability after sotalol infusion despite marked prolongation of the average QT interval. The QTV estimates of all three algorithms were inversely correlated with the amplitude of the T wave. In conclusion, template matching algorithms, in particular the time shifting algorithm, are recommended for beat-to-beat variability measurement of QT interval in body surface ECG. Recording noise, T wave amplitude and the beat-rejection strategy are important factors of QTV measurement and require further investigation. PMID:22860030

  7. Conventional QT variability measurement vs. template matching techniques: comparison of performance using simulated and real ECG.

    Directory of Open Access Journals (Sweden)

    Mathias Baumert

    Full Text Available Increased beat-to-beat variability in the QT interval (QTV of ECG has been associated with increased risk for sudden cardiac death, but its measurement is technically challenging and currently not standardized. The aim of this study was to investigate the performance of commonly used beat-to-beat QT interval measurement algorithms. Three different methods (conventional, template stretching and template time shifting were subjected to simulated data featuring typical ECG recording issues (broadband noise, baseline wander, amplitude modulation and real short-term ECG of patients before and after infusion of sotalol, a QT interval prolonging drug. Among the three algorithms, the conventional algorithm was most susceptible to noise whereas the template time shifting algorithm showed superior overall performance on simulated and real ECG. None of the algorithms was able to detect increased beat-to-beat QT interval variability after sotalol infusion despite marked prolongation of the average QT interval. The QTV estimates of all three algorithms were inversely correlated with the amplitude of the T wave. In conclusion, template matching algorithms, in particular the time shifting algorithm, are recommended for beat-to-beat variability measurement of QT interval in body surface ECG. Recording noise, T wave amplitude and the beat-rejection strategy are important factors of QTV measurement and require further investigation.

  8. Investigating Einstein-Podolsky-Rosen steering of continuous-variable bipartite states by non-Gaussian pseudospin measurements

    Science.gov (United States)

    Xiang, Yu; Xu, Buqing; Mišta, Ladislav; Tufarelli, Tommaso; He, Qiongyi; Adesso, Gerardo

    2017-10-01

    Einstein-Podolsky-Rosen (EPR) steering is an asymmetric form of correlations which is intermediate between quantum entanglement and Bell nonlocality, and can be exploited as a resource for quantum communication with one untrusted party. In particular, steering of continuous-variable Gaussian states has been extensively studied theoretically and experimentally, as a fundamental manifestation of the EPR paradox. While most of these studies focused on quadrature measurements for steering detection, two recent works revealed that there exist Gaussian states which are only steerable by suitable non-Gaussian measurements. In this paper we perform a systematic investigation of EPR steering of bipartite Gaussian states by pseudospin measurements, complementing and extending previous findings. We first derive the density-matrix elements of two-mode squeezed thermal Gaussian states in the Fock basis, which may be of independent interest. We then use such a representation to investigate steering of these states as detected by a simple nonlinear criterion, based on second moments of the correlation matrix constructed from pseudospin operators. This analysis reveals previously unexplored regimes where non-Gaussian measurements are shown to be more effective than Gaussian ones to witness steering of Gaussian states in the presence of local noise. We further consider an alternative set of pseudospin observables, whose expectation value can be expressed more compactly in terms of Wigner functions for all two-mode Gaussian states. However, according to the adopted criterion, these observables are found to be always less sensitive than conventional Gaussian observables for steering detection. Finally, we investigate continuous-variable Werner states, which are non-Gaussian mixtures of Gaussian states, and find that pseudospin measurements are always more effective than Gaussian ones to reveal their steerability. Our results provide useful insights on the role of non

  9. Context-invariant quasi hidden variable (qHV) modelling of all joint von Neumann measurements for an arbitrary Hilbert space

    International Nuclear Information System (INIS)

    Loubenets, Elena R.

    2015-01-01

    We prove the existence for each Hilbert space of the two new quasi hidden variable (qHV) models, statistically noncontextual and context-invariant, reproducing all the von Neumann joint probabilities via non-negative values of real-valued measures and all the quantum product expectations—via the qHV (classical-like) average of the product of the corresponding random variables. In a context-invariant model, a quantum observable X can be represented by a variety of random variables satisfying the functional condition required in quantum foundations but each of these random variables equivalently models X under all joint von Neumann measurements, regardless of their contexts. The proved existence of this model negates the general opinion that, in terms of random variables, the Hilbert space description of all the joint von Neumann measurements for dimH≥3 can be reproduced only contextually. The existence of a statistically noncontextual qHV model, in particular, implies that every N-partite quantum state admits a local quasi hidden variable model introduced in Loubenets [J. Math. Phys. 53, 022201 (2012)]. The new results of the present paper point also to the generality of the quasi-classical probability model proposed in Loubenets [J. Phys. A: Math. Theor. 45, 185306 (2012)

  10. Heart Rate Variability as a Measure of Airport Ramp-Traffic Controllers Workload

    Science.gov (United States)

    Hayashi, Miwa; Dulchinos, Victoria Lee

    2016-01-01

    Heart Rate Variability (HRV) has been reported to reflect the person's cognitive and emotional stress levels, and may offer an objective measure of human-operator's workload levels, which are recorded continuously and unobtrusively to the task performance. The present paper compares the HRV data collected during a human-in-the-loop simulation of airport ramp-traffic control operations with the controller participants' own verbal self-reporting ratings of their workload.

  11. A database of 10 min average measurements of solar radiation and meteorological variables in Ostrava, Czech Republic

    Directory of Open Access Journals (Sweden)

    M. Opálková

    2018-04-01

    Full Text Available A database containing 10 min means of solar irradiance measured on a horizontal plane in several ultraviolet and visible bands from July 2014 to December 2016 at three stations in the area of the city of Ostrava (Czech Republic is presented. The database contains time series of 10 min average irradiances or photosynthetic photon flux densities measured in the following spectral bands: 280–315 nm (UVB; 315–380 nm (UVA; and 400–700 nm (photosynthetically active radiation, PAR; 510–700 nm; 600–700 nm; 610–680 nm; 690–780 nm; 400–1100 nm. A series of meteorological variables including relative air humidity and air temperature at surface is also provided at the same 10 min time step at all three stations, and precipitation is provided for two stations. Air pressure, wind speed, wind direction, and concentrations of air pollutants PM10, SO2, NOx, NO, NO2 were measured at the 1 h time step at the fourth station owned by the Public Health Institute of Ostrava. The details of the experimental sites and instruments used for the measurements are given. Special attention is given to the data quality, and the original approach to the data quality which was established is described in detail. About 130 000 records for each of the three stations are available in the database. This database offers a unique ensemble of variables having a high temporal resolution and it is a reliable source for radiation in relation to environment and vegetation in highly polluted areas of industrial cities in the of northern mid-latitudes. The database has been placed on the PANGAEA repository (https://doi.org/10.1594/PANGAEA.879722 and contains individual data files for each station.

  12. A database of 10 min average measurements of solar radiation and meteorological variables in Ostrava, Czech Republic

    Science.gov (United States)

    Opálková, Marie; Navrátil, Martin; Špunda, Vladimír; Blanc, Philippe; Wald, Lucien

    2018-04-01

    A database containing 10 min means of solar irradiance measured on a horizontal plane in several ultraviolet and visible bands from July 2014 to December 2016 at three stations in the area of the city of Ostrava (Czech Republic) is presented. The database contains time series of 10 min average irradiances or photosynthetic photon flux densities measured in the following spectral bands: 280-315 nm (UVB); 315-380 nm (UVA); and 400-700 nm (photosynthetically active radiation, PAR); 510-700 nm; 600-700 nm; 610-680 nm; 690-780 nm; 400-1100 nm. A series of meteorological variables including relative air humidity and air temperature at surface is also provided at the same 10 min time step at all three stations, and precipitation is provided for two stations. Air pressure, wind speed, wind direction, and concentrations of air pollutants PM10, SO2, NOx, NO, NO2 were measured at the 1 h time step at the fourth station owned by the Public Health Institute of Ostrava. The details of the experimental sites and instruments used for the measurements are given. Special attention is given to the data quality, and the original approach to the data quality which was established is described in detail. About 130 000 records for each of the three stations are available in the database. This database offers a unique ensemble of variables having a high temporal resolution and it is a reliable source for radiation in relation to environment and vegetation in highly polluted areas of industrial cities in the of northern mid-latitudes. The database has been placed on the PANGAEA repository (https://doi.org/10.1594/PANGAEA.879722" target="_blank">https://doi.org/10.1594/PANGAEA.879722) and contains individual data files for each station.

  13. Robust shot-noise measurement for continuous-variable quantum key distribution

    Science.gov (United States)

    Kunz-Jacques, Sébastien; Jouguet, Paul

    2015-02-01

    We study a practical method to measure the shot noise in real time in continuous-variable quantum key distribution systems. The amount of secret key that can be extracted from the raw statistics depends strongly on this quantity since it affects in particular the computation of the excess noise (i.e., noise in excess of the shot noise) added by an eavesdropper on the quantum channel. Some powerful quantum hacking attacks relying on faking the estimated value of the shot noise to hide an intercept and resend strategy were proposed. Here, we provide experimental evidence that our method can defeat the saturation attack and the wavelength attack.

  14. Equations of bark thickness and volume profiles at different heights with easy-measurement variables

    Energy Technology Data Exchange (ETDEWEB)

    Cellini, J. M.; Galarza, M.; Burns, S. L.; Martinez-Pastur, G. J.; Lencinas, M. V.

    2012-11-01

    The objective of this work was to develop equations of thickness profile and bark volume at different heights with easy-measurement variables, taking as a study case Nothofagus pumilio forests, growing in different site qualities and growth phases in Southern Patagonia. Data was collected from 717 harvested trees. Three models were fitted using multiple, non-lineal regression and generalized linear model, by stepwise methodology, iteratively reweighted least squares method for maximum likelihood estimation and Marquardt algorithm. The dependent variables were diameter at 1.30 m height (DBH), relative height (RH) and growth phase (GP). The statistic evaluation was made through the adjusted determinant coefficient (r2-adj), standard error of the estimation (SEE), mean absolute error and residual analysis. All models presented good fitness with a significant correlation with the growth phase. A decrease in the thickness was observed when the relative height increase. Moreover, a bark coefficient was made to calculate volume with and without bark of individual trees, where significant differences according to site quality of the stands and DBH class of the trees were observed. It can be concluded that the prediction of bark thickness and bark coefficient is possible using DBH, height, site quality and growth phase, common and easy measurement variables used in forest inventories. (Author) 23 refs.

  15. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    International Nuclear Information System (INIS)

    Santos, Emilie M.M.; Yoo, Albert J.; Beenen, Ludo F.; Majoie, Charles B.; Berkhemer, Olvert A.; Blanken, Mark D. den; Wismans, Carrie; Niessen, Wiro J.; Marquering, Henk A.

    2016-01-01

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert observers. For 132 consecutive patients with acute ischemic stroke, three experts and two trained observers determined thrombus density by placing three standardized regions of interest (ROIs) in the thrombus and corresponding contralateral arterial segment. Subsequently, absolute and relative thrombus densities were determined using either one or three ROIs. Intraclass correlation coefficient (ICC) was determined, and Bland-Altman analysis was performed to evaluate interobserver and intermethod agreement. Accuracy of the trained observer was evaluated with a reference expert observer using the same statistical analysis. The highest interobserver agreement was obtained for absolute thrombus measurements using three ROIs (ICCs ranging from 0.54 to 0.91). In general, interobserver agreement was lower for relative measurements, and for using one instead of three ROIs. Interobserver agreement of trained non-experts and experts was similar. Accuracy of the trained observer measurements was comparable to the expert interobserver agreement and was better for absolute measurements and with three ROIs. The agreement between the one ROI and three ROI methods was good. Absolute thrombus density measurement has superior interobserver agreement compared to relative density measurement. Interobserver variation is smaller when multiple ROIs are used. Trained non-expert observers can accurately and reproducibly assess absolute thrombus densities using three ROIs. (orig.)

  16. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Emilie M.M. [Erasmus MC - University Medical Center Rotterdam, Department of Radiology, P.O. Box 2040, Rotterdam (Netherlands); Department of Radiology, AMC, Amsterdam (Netherlands); Yoo, Albert J. [Texas Stroke Institute, Plano, TX (United States); Beenen, Ludo F.; Majoie, Charles B. [Department of Radiology, AMC, Amsterdam (Netherlands); Berkhemer, Olvert A. [Department of Radiology, AMC, Amsterdam (Netherlands); Department of Neurology, Erasmus MC, Rotterdam (Netherlands); Blanken, Mark D. den; Wismans, Carrie [AMC, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Niessen, Wiro J. [Erasmus MC - University Medical Center Rotterdam, Department of Radiology, P.O. Box 2040, Rotterdam (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Delft (Netherlands); Marquering, Henk A. [Department of Radiology, AMC, Amsterdam (Netherlands); AMC, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Collaboration: on behalf of the MR CLEAN investigators

    2016-02-15

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert observers. For 132 consecutive patients with acute ischemic stroke, three experts and two trained observers determined thrombus density by placing three standardized regions of interest (ROIs) in the thrombus and corresponding contralateral arterial segment. Subsequently, absolute and relative thrombus densities were determined using either one or three ROIs. Intraclass correlation coefficient (ICC) was determined, and Bland-Altman analysis was performed to evaluate interobserver and intermethod agreement. Accuracy of the trained observer was evaluated with a reference expert observer using the same statistical analysis. The highest interobserver agreement was obtained for absolute thrombus measurements using three ROIs (ICCs ranging from 0.54 to 0.91). In general, interobserver agreement was lower for relative measurements, and for using one instead of three ROIs. Interobserver agreement of trained non-experts and experts was similar. Accuracy of the trained observer measurements was comparable to the expert interobserver agreement and was better for absolute measurements and with three ROIs. The agreement between the one ROI and three ROI methods was good. Absolute thrombus density measurement has superior interobserver agreement compared to relative density measurement. Interobserver variation is smaller when multiple ROIs are used. Trained non-expert observers can accurately and reproducibly assess absolute thrombus densities using three ROIs. (orig.)

  17. Use of UAVs for Remote Measurement of Vegetation Canopy Variables

    Science.gov (United States)

    Rango, A.; Laliberte, A.; Herrick, J.; Steele, C.; Bestelmeyer, B.; Chopping, M. J.

    2006-12-01

    Remote sensing with different sensors has proven useful for measuring vegetation canopy variables at scales ranging from landscapes down to individual plants. For use at landscape scales, such as desert grasslands invaded by shrubs, it is possible to use multi-angle imagery from satellite sensors, such as MISR and CHRIS/Proba, with geometric optical models to retrieve fractional woody plant cover. Vegetation community states can be mapped using visible and near infrared ASTER imagery at 15 m resolution. At finer scales, QuickBird satellite imagery with approximately 60 cm resolution and piloted aircraft photography with 25-80 cm resolution can be used to measure shrubs above a critical size. Tests conducted with the QuickBird data in the Jornada basin of southern New Mexico have shown that 87% of all shrubs greater than 2 m2 were detected whereas only about 29% of all shrubs less than 2 m2 were detected, even at these high resolutions. Because there is an observational gap between satellite/aircraft measurements and ground observations, we have experimented with Unmanned Aerial Vehicles (UAVs) producing digital photography with approximately 5 cm resolution. We were able to detect all shrubs greater than 2 m2, and we were able to map small subshrubs indicative of rangeland deterioration, as well as remnant grass patches, for the first time. None of these could be identified on the 60 cm resolution data. Additionally, we were able to measure canopy gaps, shrub patterns, percent bare soil, and vegetation cover over mixed rangeland vegetation. This approach is directly applicable to rangeland health monitoring, and it provides a quantitative way to assess shrub invasion over time and to detect the depletion or recovery of grass patches. Further, if the UAV images have sufficient overlap, it may be possible to exploit the stereo viewing capabilities to develop a digital elevation model from the orthophotos, with a potential for extracting canopy height. We envision two

  18. Method and system to estimate variables in an integrated gasification combined cycle (IGCC) plant

    Science.gov (United States)

    Kumar, Aditya; Shi, Ruijie; Dokucu, Mustafa

    2013-09-17

    System and method to estimate variables in an integrated gasification combined cycle (IGCC) plant are provided. The system includes a sensor suite to measure respective plant input and output variables. An extended Kalman filter (EKF) receives sensed plant input variables and includes a dynamic model to generate a plurality of plant state estimates and a covariance matrix for the state estimates. A preemptive-constraining processor is configured to preemptively constrain the state estimates and covariance matrix to be free of constraint violations. A measurement-correction processor may be configured to correct constrained state estimates and a constrained covariance matrix based on processing of sensed plant output variables. The measurement-correction processor is coupled to update the dynamic model with corrected state estimates and a corrected covariance matrix. The updated dynamic model may be configured to estimate values for at least one plant variable not originally sensed by the sensor suite.

  19. Evaluation of Heart Rate Variability by means of Laser Doppler Vibrometry measurements

    International Nuclear Information System (INIS)

    Cosoli, G; Casacanditella, L; Tomasini, EP; Scalise, L

    2015-01-01

    Heart Rate Variability (HRV) analysis aims to study the physiological variability of the Heart Rate (HR), which is related to the health conditions of the subject. HRV is assessed measuring heart periods (HP) on a time window of >5 minutes (1)-(2). HPs are determined from signals of different nature: electrocardiogram (ECG), photoplethysmogram (PPG), phonocardiogram (PCG) or vibrocardiogram (VCG) (3)-(4)-(5). The fundamental aspect is the identification of a feature in each heartbeat that allows to accurately compute cardiac periods (such as R peaks in ECG), in order to make possible the measurement of all the typical HRV evaluations on those intervals. VCG is a non-contact technique (4), very favourable in medicine, which detects the vibrations on the skin surface (e.g. on the carotid artery) resulting from vascular blood motion consequent to electrical signal (ECG).In this paper, we propose the use of VCG for the measurement of a signal related to HRV and the use of a novel algorithm based on signal geometry (7) to detect signal peaks, in order to accurately determine cardiac periods and the Poincare plot (9)-(10). The results reported are comparable to the ones reached with the gold standard (ECG) and in literature (3)-(5). We report mean values of HP of 832±54 ms and 832±55 ms by means of ECG and VCG, respectively. Moreover, this algorithm allow us to identify particular features of ECG and VCG signals, so that in the future we will be able to evaluate specific correlations between the two. (paper)

  20. Difference infiltrometer: a method to measure temporally variable infiltration rates during rainstorms

    Science.gov (United States)

    Moody, John A.; Ebel, Brian A.

    2012-01-01

    We developed a difference infiltrometer to measure time series of non-steady infiltration rates during rainstorms at the point scale. The infiltrometer uses two, tipping bucket rain gages. One gage measures rainfall onto, and the other measures runoff from, a small circular plot about 0.5-m in diameter. The small size allows the infiltration rate to be computed as the difference of the cumulative rainfall and cumulative runoff without having to route water through a large plot. Difference infiltrometers were deployed in an area burned by the 2010 Fourmile Canyon Fire near Boulder, Colorado, USA, and data were collected during the summer of 2011. The difference infiltrometer demonstrated the capability to capture different magnitudes of infiltration rates and temporal variability associated with convective (high intensity, short duration) and cyclonic (low intensity, long duration) rainstorms. Data from the difference infiltrometer were used to estimate saturated hydraulic conductivity of soil affected by the heat from a wildfire. The difference infiltrometer is portable and can be deployed in rugged, steep terrain and does not require the transport of water, as many rainfall simulators require, because it uses natural rainfall. It can be used to assess infiltration models, determine runoff coefficients, identify rainfall depth or rainfall intensity thresholds to initiate runoff, estimate parameters for infiltration models, and compare remediation treatments on disturbed landscapes. The difference infiltrometer can be linked with other types of soil monitoring equipment in long-term studies for detecting temporal and spatial variability at multiple time scales and in nested designs where it can be linked to hillslope and basin-scale runoff responses.

  1. Statistical methodology for discrete fracture model - including fracture size, orientation uncertainty together with intensity uncertainty and variability

    International Nuclear Information System (INIS)

    Darcel, C.; Davy, P.; Le Goc, R.; Dreuzy, J.R. de; Bour, O.

    2009-11-01

    the other, addresses the issue of the nature of the transition. We develop a new 'mechanistic' model that could help in modeling why and where this transition can occur. The transition between both regimes would occur for a fracture length of 1-10 m and even at a smaller scale for the few outcrops that follow the self-similar density model. A consequence for the disposal issue is that the model that is likely to apply in the 'blind' scale window between 10-100 m is the self-similar model as it is defined for large-scale lineaments. The self-similar model, as it is measured for some outcrops and most lineament maps, is definitely worth being investigated as a reference for scales above 1-10 m. In the rest of the report, we develop a methodology for incorporating uncertainty and variability into the DFN modeling. Fracturing properties arise from complex processes which produce an intrinsic variability; characterizing this variability as an admissible variation of model parameter or as the division of the site into subdomains with distinct DFN models is a critical point of the modeling effort. Moreover, the DFN model encompasses a part of uncertainty, due to data inherent uncertainties and sampling limits. Both effects must be quantified and incorporated into the DFN site model definition process. In that context, all available borehole data including recording of fracture intercept positions, pole orientation and relative uncertainties are used as the basis for the methodological development and further site model assessment. An elementary dataset contains a set of discrete fracture intercepts from which a parent orientation/density distribution can be computed. The elementary bricks of the site, from which these initial parent density distributions are computed, rely on the former Single Hole Interpretation division of the boreholes into sections whose local boundaries are expected to reflect - locally - geology and fracturing properties main characteristics. From that

  2. Statistical variability of hydro-meteorological variables as indicators ...

    African Journals Online (AJOL)

    Statistical variability of hydro-meteorological variables as indicators of climate change in north-east Sokoto-Rima basin, Nigeria. ... water resources development including water supply project, agriculture and tourism in the study area. Key word: Climate change, Climatic variability, Actual evapotranspiration, Global warming ...

  3. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    International Nuclear Information System (INIS)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders; Andersson, Anna; Biglarnia, Ali-Reza

    2012-01-01

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume

  4. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders [Uppsala Univ., Dept. of Radiology, Oncology and Radiation Science, Section of Radiology, Uppsala (Sweden)], E-mail: eva.lundqvist.8954@student.uu.se; Andersson, Anna; Biglarnia, Ali-Reza [Dept. of Surgical Sciences, Section of Transplantation Surgery, Uppsala Univ. Hospital, Uppsala (Sweden)

    2012-11-15

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume.

  5. Measuring variability in trophic status in the Lake Waco/Bosque River Watershed

    Directory of Open Access Journals (Sweden)

    Rodriguez Angela D

    2008-01-01

    Full Text Available Abstract Background Nutrient management in rivers and streams is difficult due to the spatial and temporal variability of algal growth responses. The objectives of this project were to determine the spatial and seasonal in situ variability of trophic status in the Lake Waco/Bosque River watershed, determine the variability in the lotic ecosystem trophic status index (LETSI at each site as indicators of the system's nutrient sensitivity, and determine if passive diffusion periphytometers could provide threshold algal responses to nutrient enrichment. Methods We used the passive diffusion periphytometer to measure in-situ nutrient limitation and trophic status at eight sites in five streams in the Lake Waco/Bosque River Watershed in north-central Texas from July 1997 through October 1998. The chlorophyll a production in the periphytometers was used as an indicator of baseline chlorophyll a productivity and of maximum primary productivity (MPP in response to nutrient enrichment (nitrogen and phosphorus. We evaluated the lotic ecosystem trophic status index (LETSI using the ratio of baseline primary productivity to MPP, and evaluated the trophic class of each site. Results The rivers and streams in the Lake Waco/Bosque River Watershed exhibited varying degrees of nutrient enrichment over the 18-month sampling period. The North Bosque River at the headwaters (NB-02 located below the Stephenville, Texas wastewater treatment outfall consistently exhibited the highest degree of water quality impact due to nutrient enrichment. Sites at the outlet of the watershed (NB-04 and NB-05 were the next most enriched sites. Trophic class varied for enriched sites over seasons. Conclusion Seasonality played a significant role in the trophic class and sensitivity of each site to nutrients. Managing rivers and streams for nutrients will require methods for measuring in situ responses and sensitivities to nutrient enrichment. Nutrient enrichment periphytometers show

  6. Intra- and interobserver variability of MRI-based volume measurements of the hippocampus and amygdala using the manual ray-tracing method

    International Nuclear Information System (INIS)

    Achten, E.; Deblaere, K.; Damme, F. van; Kunnen, M.; Wagter, C. de; Boon, P.; Reuck, J. de

    1998-01-01

    We studied the intra- and interobserver variability of volume measurments of the hippocampus (HC) and the amygdala as applied to the detection of HC atrophy in patients with complex partial seizures (CPE), measuring the volumes of the HC and amygdala of 11 normal volunteers and 12 patients with presumed CPE, using the manual ray-tracing method. Two independent observers performed these measurements twice each using home-made software. The intra- and interobserver variability of the absolute volumes and of the normalised left-to-right volume differences (δV) between the HC (δV HC ), the amygdala (δV A ) and the sum of both (δV HCA) were assessed. In our mainly right-handed normals, the right HC and amygdala were on average 0.05 and 0.03 ml larger respectively than on the left. The interobserver variability for volume measurements in normal subjects was 1.80 ml for the HC and 0.82 ml for the amygdala, the intraobserver variability roughly one third of these values. The interobserver variability coefficient in normals was 3.6 % for δV HCA , 4.7 % for δV HC and 7.3 % for δV A . The intraobserver variability coefficient was 3.4 % for δV HCA , 4.2 % for δV HC amd 5.6 % for δV A . The variability in patients was the same for volume differences less than 5 % either side of the interval for normality, but was higher when large volume differences were encountered, is probably due to the lack of thresholding and/or normalisation. Cutoff values for lateralisation with the δV were defined. No intra- or interobserver lateralisation differences were encountered with δV HCA and δV HC . From these observations we conclude that the manual ray-tracing method is a robust method for lateralisation in patients with TLE. Due to its higher variability, this method is less suited to measure absolute volumes. (orig.) (orig.)

  7. Intra- and interobserver variability of MRI-based volume measurements of the hippocampus and amygdala using the manual ray-tracing method

    Energy Technology Data Exchange (ETDEWEB)

    Achten, E.; Deblaere, K.; Damme, F. van; Kunnen, M. [MR Department 1K12, University Hospital Gent (Belgium); Wagter, C. de [Department of Radiotherapy and Nuclear Medicine, University Hospital Gent (Belgium); Boon, P.; Reuck, J. de [Department of Neurology, University Hospital Gent (Belgium)

    1998-09-01

    We studied the intra- and interobserver variability of volume measurments of the hippocampus (HC) and the amygdala as applied to the detection of HC atrophy in patients with complex partial seizures (CPE), measuring the volumes of the HC and amygdala of 11 normal volunteers and 12 patients with presumed CPE, using the manual ray-tracing method. Two independent observers performed these measurements twice each using home-made software. The intra- and interobserver variability of the absolute volumes and of the normalised left-to-right volume differences ({delta}V) between the HC ({delta}V{sub HC}), the amygdala ({delta}V{sub A}) and the sum of both ({delta}V{sub HCA)} were assessed. In our mainly right-handed normals, the right HC and amygdala were on average 0.05 and 0.03 ml larger respectively than on the left. The interobserver variability for volume measurements in normal subjects was 1.80 ml for the HC and 0.82 ml for the amygdala, the intraobserver variability roughly one third of these values. The interobserver variability coefficient in normals was 3.6 % for {delta}V{sub HCA}, 4.7 % for {delta}V{sub HC} and 7.3 % for {delta}V{sub A}. The intraobserver variability coefficient was 3.4 % for {delta}V{sub HCA}, 4.2 % for {delta}V{sub HC} amd 5.6 % for {delta}V{sub A}. The variability in patients was the same for volume differences less than 5 % either side of the interval for normality, but was higher when large volume differences were encountered, is probably due to the lack of thresholding and/or normalisation. Cutoff values for lateralisation with the {delta}V were defined. No intra- or interobserver lateralisation differences were encountered with {delta}V{sub HCA} and {delta}V{sub HC}. From these observations we conclude that the manual ray-tracing method is a robust method for lateralisation in patients with TLE. Due to its higher variability, this method is less suited to measure absolute volumes. (orig.) (orig.) With 2 figs., 7 tabs., 23 refs.

  8. Retrieval of Water Constituents from Hyperspectral In-Situ Measurements under Variable Cloud Cover—A Case Study at Lake Stechlin (Germany

    Directory of Open Access Journals (Sweden)

    Anna Göritz

    2018-01-01

    Full Text Available Remote sensing and field spectroscopy of natural waters is typically performed under clear skies, low wind speeds and low solar zenith angles. Such measurements can also be made, in principle, under clouds and mixed skies using airborne or in-situ measurements; however, variable illumination conditions pose a challenge to data analysis. In the present case study, we evaluated the inversion of hyperspectral in-situ measurements for water constituent retrieval acquired under variable cloud cover. First, we studied the retrieval of Chlorophyll-a (Chl-a concentration and colored dissolved organic matter (CDOM absorption from in-water irradiance measurements. Then, we evaluated the errors in the retrievals of the concentration of total suspended matter (TSM, Chl-a and the absorption coefficient of CDOM from above-water reflectance measurements due to highly variable reflections at the water surface. In order to approximate cloud reflections, we extended a recent three-component surface reflectance model for cloudless atmospheres by a constant offset and compared different surface reflectance correction procedures. Our findings suggest that in-water irradiance measurements may be used for the analysis of absorbing compounds even under highly variable weather conditions. The extended surface reflectance model proved to contribute to the analysis of above-water reflectance measurements with respect to Chl-a and TSM. Results indicate the potential of this approach for all-weather monitoring.

  9. Carpet-dust chemicals as measures of exposure: Implications of variability

    Directory of Open Access Journals (Sweden)

    Whitehead Todd P

    2012-03-01

    Full Text Available Abstract Background There is increasing interest in using chemicals measured in carpet dust as indicators of chemical exposures. However, investigators have rarely sampled dust repeatedly from the same households and therefore little is known about the variability of chemical levels that exist within and between households in dust samples. Results We analyzed 9 polycyclic aromatic hydrocarbons, 6 polychlorinated biphenyls, and nicotine in 68 carpet-dust samples from 21 households in agricultural communities of Fresno County, California collected from 2003-2005. Chemical concentrations (ng per g dust ranged from Conclusions Our findings suggest that attenuation bias should be relatively modest when using these semi-volatile carpet-dust chemicals as exposure surrogates in epidemiologic studies.

  10. Assessing soil hydrological variability at the cm- to dm-scale using air permeameter measurements

    Science.gov (United States)

    Beerten, K.; Vandersmissen, N.; Rogiers, B.; Mallants, D.

    2012-04-01

    Soils and surficial sediments are crucial elements in the hydrological cycle since they are the medium through which infiltrating precipitation percolates to the aquifer. At the same time, soil horizons and shallow stratigraphy may act as hydraulic barriers that can promote runoff or interflow and hamper deep infiltration. For most catchments little is known about the small-scale horizontal and vertical variability of soil hydrological properties. Such information is however required to calculate detailed soil water flow paths and estimate small scale spatial variability in recharge and run-off. We present the results from field air permeameter measurements to assess the small-scale variability of saturated hydraulic conductivity in heterogeneous 2-D soil profiles. To this end, several outcrops in the unsaturated zone (sandy soils with podzolisation) of an interfluve in the Kleine Nete river catchment (Campine area, Northern Belgium) were investigated using a hand-held permeameter. Measurements were done each 10 cm on ~ 2 x 1 m or ~ 2 x 0.5 m grids. The initial results of the measurements (air permeability Kair; millidarcy) are recalculated to saturated hydraulic conductivity (Ks; m/s) using specific transfer functions (Loll et al., 1999; Iversen et al., 2003). Validation of the results is done with independent lab-based constant head Ks measurements. The results show that field based Ks values generally range between 10-3 m/s and 10-7 m/s within one profile, but extremely high values (up to 10-1 m/s) have been measured as well. The lowest values are found in the organic- and silt-rich Bh horizon of podzol soils observed within the profiles (~ 10-6-10-7m/s), while the highest values are observed in overlying dune sands less than 40 cm deep (up to 10-3 m/s with outliers to 10-1 m/s). Comparison of field and laboratory based Ks data reveals there is fair agreement between both methods, apart from several outliers. Scatter plots indicate that almost all points

  11. Variability and accuracy of coronary CT angiography including use of iterative reconstruction algorithms for plaque burden assessment as compared with intravascular ultrasound - an ex vivo study

    Energy Technology Data Exchange (ETDEWEB)

    Stolzmann, Paul [Massachusetts General Hospital and Harvard Medical School, Cardiac MR PET CT Program, Boston, MA (United States); University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Schlett, Christopher L.; Maurovich-Horvat, Pal; Scheffel, Hans; Engel, Leif-Christopher; Karolyi, Mihaly; Hoffmann, Udo [Massachusetts General Hospital and Harvard Medical School, Cardiac MR PET CT Program, Boston, MA (United States); Maehara, Akiko; Ma, Shixin; Mintz, Gary S. [Columbia University Medical Center, Cardiovascular Research Foundation, New York, NY (United States)

    2012-10-15

    To systematically assess inter-technique and inter-/intra-reader variability of coronary CT angiography (CTA) to measure plaque burden compared with intravascular ultrasound (IVUS) and to determine whether iterative reconstruction algorithms affect variability. IVUS and CTA data were acquired from nine human coronary arteries ex vivo. CT images were reconstructed using filtered back projection (FBPR) and iterative reconstruction algorithms: adaptive-statistical (ASIR) and model-based (MBIR). After co-registration of 284 cross-sections between IVUS and CTA, two readers manually delineated the cross-sectional plaque area in all images presented in random order. Average plaque burden by IVUS was 63.7 {+-} 10.7% and correlated significantly with all CTA measurements (r = 0.45-0.52; P < 0.001), while CTA overestimated the burden by 10 {+-} 10%. There were no significant differences among FBPR, ASIR and MBIR (P > 0.05). Increased overestimation was associated with smaller plaques, eccentricity and calcification (P < 0.001). Reproducibility of plaque burden by CTA and IVUS datasets was excellent with a low mean intra-/inter-reader variability of <1/<4% for CTA and <0.5/<1% for IVUS respectively (P < 0.05) with no significant difference between CT reconstruction algorithms (P > 0.05). In ex vivo coronary arteries, plaque burden by coronary CTA had extremely low inter-/intra-reader variability and correlated significantly with IVUS measurements. Accuracy as well as reader reliability were independent of CT image reconstruction algorithm. (orig.)

  12. Variability of carotid artery measurements on 3-Tesla MRI and its impact on sample size calculation for clinical research.

    Science.gov (United States)

    Syed, Mushabbar A; Oshinski, John N; Kitchen, Charles; Ali, Arshad; Charnigo, Richard J; Quyyumi, Arshed A

    2009-08-01

    Carotid MRI measurements are increasingly being employed in research studies for atherosclerosis imaging. The majority of carotid imaging studies use 1.5 T MRI. Our objective was to investigate intra-observer and inter-observer variability in carotid measurements using high resolution 3 T MRI. We performed 3 T carotid MRI on 10 patients (age 56 +/- 8 years, 7 male) with atherosclerosis risk factors and ultrasound intima-media thickness > or =0.6 mm. A total of 20 transverse images of both right and left carotid arteries were acquired using T2 weighted black-blood sequence. The lumen and outer wall of the common carotid and internal carotid arteries were manually traced; vessel wall area, vessel wall volume, and average wall thickness measurements were then assessed for intra-observer and inter-observer variability. Pearson and intraclass correlations were used in these assessments, along with Bland-Altman plots. For inter-observer variability, Pearson correlations ranged from 0.936 to 0.996 and intraclass correlations from 0.927 to 0.991. For intra-observer variability, Pearson correlations ranged from 0.934 to 0.954 and intraclass correlations from 0.831 to 0.948. Calculations showed that inter-observer variability and other sources of error would inflate sample size requirements for a clinical trial by no more than 7.9%, indicating that 3 T MRI is nearly optimal in this respect. In patients with subclinical atherosclerosis, 3 T carotid MRI measurements are highly reproducible and have important implications for clinical trial design.

  13. The reproducibility and variability of sequential left ventricular ejection fraction measurements by the nuclear stethoscope

    International Nuclear Information System (INIS)

    Kurata, Chinori; Hayashi, Hideharu; Kobayashi, Akira; Yamazaki, Noboru

    1986-01-01

    We evaluated the reproducibility and variability of sequential left ventricular ejection fraction (LVEF) measurements by the nuclear stethoscope in 72 patients. The group as a whole demonstrated excellent reproducibility (r = 0.96). However, repeat LVEF measurements by the nuclear stethoscope at 5-minute interval showed around 9 % absolute difference, at 95 % confidence levels, from one measurement to the next. The finding indicates that a change in LVEF greater than 9 % is necessary for determining an acute effect of an intervention in individual cases. (author)

  14. Variability of indoor and outdoor VOC measurements: An analysis using variance components

    International Nuclear Information System (INIS)

    Jia, Chunrong; Batterman, Stuart A.; Relyea, George E.

    2012-01-01

    This study examines concentrations of volatile organic compounds (VOCs) measured inside and outside of 162 residences in southeast Michigan, U.S.A. Nested analyses apportioned four sources of variation: city, residence, season, and measurement uncertainty. Indoor measurements were dominated by seasonal and residence effects, accounting for 50 and 31%, respectively, of the total variance. Contributions from measurement uncertainty (<20%) and city effects (<10%) were small. For outdoor measurements, season, city and measurement variation accounted for 43, 29 and 27% of variance, respectively, while residence location had negligible impact (<2%). These results show that, to obtain representative estimates of indoor concentrations, measurements in multiple seasons are required. In contrast, outdoor VOC concentrations can use multi-seasonal measurements at centralized locations. Error models showed that uncertainties at low concentrations might obscure effects of other factors. Variance component analyses can be used to interpret existing measurements, design effective exposure studies, and determine whether the instrumentation and protocols are satisfactory. - Highlights: ► The variability of VOC measurements was partitioned using nested analysis. ► Indoor VOCs were primarily controlled by seasonal and residence effects. ► Outdoor VOC levels were homogeneous within neighborhoods. ► Measurement uncertainty was high for many outdoor VOCs. ► Variance component analysis is useful for designing effective sampling programs. - Indoor VOC concentrations were primarily controlled by seasonal and residence effects; and outdoor concentrations were homogeneous within neighborhoods. Variance component analysis is a useful tool for designing effective sampling programs.

  15. Measure Guideline. Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States); Easley, S. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States)

    2012-05-01

    This measure guideline evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provides a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  16. Measuring pH variability using an experimental sensor on an underwater glider

    Science.gov (United States)

    Hemming, Michael P.; Kaiser, Jan; Heywood, Karen J.; Bakker, Dorothee C. E.; Boutin, Jacqueline; Shitashima, Kiminori; Lee, Gareth; Legge, Oliver; Onken, Reiner

    2017-05-01

    Autonomous underwater gliders offer the capability of measuring oceanic parameters continuously at high resolution in both vertical and horizontal planes, with timescales that can extend to many months. An experimental ion-sensitive field-effect transistor (ISFET) sensor measuring pH on the total scale was attached to a glider during the REP14-MED experiment in June 2014 in the Sardinian Sea in the northwestern Mediterranean. During the deployment, pH was sampled at depths of up to 1000 m along an 80 km transect over a period of 12 days. Water samples were collected from a nearby ship and analysed for dissolved inorganic carbon concentration and total alkalinity to derive the pH for validating the ISFET sensor measurements. The vertical resolution of the pH sensor was good (1 to 2 m), but stability was poor and the sensor drifted in a non-monotonous fashion. In order to remove the sensor drift, a depth-constant time-varying offset was applied throughout the water column for each dive, reducing the spread of the data by approximately two-thirds. Furthermore, the ISFET sensor required temperature- and pressure-based corrections, which were achieved using linear regression. Correcting for this decreased the apparent sensor pH variability by a further 13 to 31 %. Sunlight caused an apparent sensor pH decrease of up to 0.1 in surface waters around local noon, highlighting the importance of shielding the sensor from light in future deployments. The corrected pH from the ISFET sensor is presented along with potential temperature, salinity, potential density anomalies (σθ), and dissolved oxygen concentrations (c(O2)) measured by the glider, providing insights into the physical and biogeochemical variability in the Sardinian Sea. The pH maxima were identified close to the depth of the summer chlorophyll maximum, where high c(O2) values were also found. Longitudinal pH variations at depth (σθ > 28. 8 kg m-3) highlighted the variability of water masses in the Sardinian

  17. Measuring pH variability using an experimental sensor on an underwater glider

    Directory of Open Access Journals (Sweden)

    M. P. Hemming

    2017-05-01

    Full Text Available Autonomous underwater gliders offer the capability of measuring oceanic parameters continuously at high resolution in both vertical and horizontal planes, with timescales that can extend to many months. An experimental ion-sensitive field-effect transistor (ISFET sensor measuring pH on the total scale was attached to a glider during the REP14-MED experiment in June 2014 in the Sardinian Sea in the northwestern Mediterranean. During the deployment, pH was sampled at depths of up to 1000 m along an 80 km transect over a period of 12 days. Water samples were collected from a nearby ship and analysed for dissolved inorganic carbon concentration and total alkalinity to derive the pH for validating the ISFET sensor measurements. The vertical resolution of the pH sensor was good (1 to 2 m, but stability was poor and the sensor drifted in a non-monotonous fashion. In order to remove the sensor drift, a depth-constant time-varying offset was applied throughout the water column for each dive, reducing the spread of the data by approximately two-thirds. Furthermore, the ISFET sensor required temperature- and pressure-based corrections, which were achieved using linear regression. Correcting for this decreased the apparent sensor pH variability by a further 13 to 31 %. Sunlight caused an apparent sensor pH decrease of up to 0.1 in surface waters around local noon, highlighting the importance of shielding the sensor from light in future deployments. The corrected pH from the ISFET sensor is presented along with potential temperature, salinity, potential density anomalies (σθ, and dissolved oxygen concentrations (c(O2 measured by the glider, providing insights into the physical and biogeochemical variability in the Sardinian Sea. The pH maxima were identified close to the depth of the summer chlorophyll maximum, where high c(O2 values were also found. Longitudinal pH variations at depth (σθ > 28. 8 kg m−3 highlighted the variability of

  18. Measuring Zonal Transport Variability of the Antarctic Circumpolar Current Using GRACE Ocean Bottom Pressure

    Science.gov (United States)

    Makowski, J.; Chambers, D. P.; Bonin, J. A.

    2012-12-01

    Previous studies have suggested that ocean bottom pressure (OBP) can be used to measure the transport variability of the Antarctic Circumpolar Current (ACC). Using OBP data from the JPL ECCO model and the Gravity Recovery and Climate Experiment (GRACE), we examine the zonal transport variability of the ACC integrated between the major fronts between 2003-2010. The JPL ECCO data are used to determine average front positions for the time period studies, as well as where transport is mainly zonal. Statistical analysis will be conducted to determine the uncertainty of the GRACE observations using a simulated data set. We will also begin looking at low frequency changes and how coherent transport variability is from region to region of the ACC. Correlations with bottom pressure south of the ACC and the average basin transports will also be calculated to determine the probability of using bottom pressure south of the ACC as a means for describing the ACC dynamics and transport.

  19. Characterization of SiO2/SiC interface states and channel mobility from MOSFET characteristics including variable-range hopping at cryogenic temperature

    Directory of Open Access Journals (Sweden)

    Hironori Yoshioka

    2018-04-01

    Full Text Available The characteristics of SiC MOSFETs (drain current vs. gate voltage were measured at 0.14−350 K and analyzed considering variable-range hopping conduction through interface states. The total interface state density was determined to be 5.4×1012 cm−2 from the additional shift in the threshold gate voltage with a temperature change. The wave-function size of interface states was determined from the temperature dependence of the measured hopping current and was comparable to the theoretical value. The channel mobility was approximately 100 cm2V−1s−1 and was almost independent of temperature.

  20. Characterization of SiO2/SiC interface states and channel mobility from MOSFET characteristics including variable-range hopping at cryogenic temperature

    Science.gov (United States)

    Yoshioka, Hironori; Hirata, Kazuto

    2018-04-01

    The characteristics of SiC MOSFETs (drain current vs. gate voltage) were measured at 0.14-350 K and analyzed considering variable-range hopping conduction through interface states. The total interface state density was determined to be 5.4×1012 cm-2 from the additional shift in the threshold gate voltage with a temperature change. The wave-function size of interface states was determined from the temperature dependence of the measured hopping current and was comparable to the theoretical value. The channel mobility was approximately 100 cm2V-1s-1 and was almost independent of temperature.

  1. Global Analysis of Solar Neutrino Oscillations Including SNO CC Measurement

    CERN Document Server

    Bahcall, J N; Peña-Garay, C; Bahcall, John N; Peña-Garay, Carlos

    2001-01-01

    For active and sterile neutrinos, we present the globally allowed solutions for two neutrino oscillations. We include the SNO CC measurement and all other relevant solar neutrino and reactor data. Five active neutrino oscillation solutions (LMA, LOW, SMA, VAC, and Just So2) are currently allowed at 3 sigma; three sterile neutrino solutions (Just So2, SMA, and VAC) are allowed at 3 sigma. The goodness of fit is satisfactory for all eight solutions. We also investigate the robustness of the allowed solutions by carrying out global analyses with and without: 1) imposing solar model constraints on the 8B neutrino flux, 2) including the Super-Kamiokande spectral energy distribution and day-night data, 3) using an enhanced CC cross section for deuterium (due to radiative corrections), and 4) a optimistic, hypothetical reduction by a factor of three of the error of the SNO CC rate. For every analysis strategy used in this paper, the most favored solutions all involve large mixing angles: LMA, LOW, or VAC. The favore...

  2. A bivariate measurement error model for semicontinuous and continuous variables: Application to nutritional epidemiology.

    Science.gov (United States)

    Kipnis, Victor; Freedman, Laurence S; Carroll, Raymond J; Midthune, Douglas

    2016-03-01

    Semicontinuous data in the form of a mixture of a large portion of zero values and continuously distributed positive values frequently arise in many areas of biostatistics. This article is motivated by the analysis of relationships between disease outcomes and intakes of episodically consumed dietary components. An important aspect of studies in nutritional epidemiology is that true diet is unobservable and commonly evaluated by food frequency questionnaires with substantial measurement error. Following the regression calibration approach for measurement error correction, unknown individual intakes in the risk model are replaced by their conditional expectations given mismeasured intakes and other model covariates. Those regression calibration predictors are estimated using short-term unbiased reference measurements in a calibration substudy. Since dietary intakes are often "energy-adjusted," e.g., by using ratios of the intake of interest to total energy intake, the correct estimation of the regression calibration predictor for each energy-adjusted episodically consumed dietary component requires modeling short-term reference measurements of the component (a semicontinuous variable), and energy (a continuous variable) simultaneously in a bivariate model. In this article, we develop such a bivariate model, together with its application to regression calibration. We illustrate the new methodology using data from the NIH-AARP Diet and Health Study (Schatzkin et al., 2001, American Journal of Epidemiology 154, 1119-1125), and also evaluate its performance in a simulation study. © 2015, The International Biometric Society.

  3. Variability in baseline laboratory measurements of the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil).

    Science.gov (United States)

    Ladwig, R; Vigo, A; Fedeli, L M G; Chambless, L E; Bensenor, I; Schmidt, M I; Vidigal, P G; Castilhos, C D; Duncan, B B

    2016-08-01

    Multi-center epidemiological studies must ascertain that their measurements are accurate and reliable. For laboratory measurements, reliability can be assessed through investigation of reproducibility of measurements in the same individual. In this paper, we present results from the quality control analysis of the baseline laboratory measurements from the ELSA-Brasil study. The study enrolled 15,105 civil servants at 6 research centers in 3 regions of Brazil between 2008-2010, with multiple biochemical analytes being measured at a central laboratory. Quality control was ascertained through standard laboratory evaluation of intra- and inter-assay variability and test-retest analysis in a subset of randomly chosen participants. An additional sample of urine or blood was collected from these participants, and these samples were handled in the same manner as the original ones, locally and at the central laboratory. Reliability was assessed with the intraclass correlation coefficient (ICC), estimated through a random effects model. Coefficients of variation (CV) and Bland-Altman plots were additionally used to assess measurement variability. Laboratory intra and inter-assay CVs varied from 0.86% to 7.77%. From test-retest analyses, the ICCs were high for the majority of the analytes. Notably lower ICCs were observed for serum sodium (ICC=0.50; 95%CI=0.31-0.65) and serum potassium (ICC=0.73; 95%CI=0.60-0.83), due to the small biological range of these analytes. The CVs ranged from 1 to 14%. The Bland-Altman plots confirmed these results. The quality control analyses showed that the collection, processing and measurement protocols utilized in the ELSA-Brasil produced reliable biochemical measurements.

  4. Internet interventions for chronic pain including headache: A systematic review

    Directory of Open Access Journals (Sweden)

    Monica Buhrman

    2016-05-01

    Full Text Available Chronic pain is a major health problem and behavioral based treatments have been shown to be effective. However, the availability of these kinds of treatments is scarce and internet-based treatments have been shown to be promising in this area. The objective of the present systematic review is to evaluate internet-based interventions for persons with chronic pain. The specific aims are to do an updated review with a broad inclusion of different chronic pain diagnoses and to assess disability and pain and also measures of catastrophizing, depression and anxiety. A systematic search identified 891 studies and 22 trials were selected as eligible for review. Two of the selected trials included children/youth and five included individuals with chronic headache and/or migraine. The most frequently measured domain reflected in the primary outcomes was interference/disability, followed by catastrophizing. Result across the studies showed a number of beneficial effects. Twelve trials reported significant effects on disability/interference outcomes and pain intensity. Positive effects were also found on psychological variable such as catastrophizing, depression and anxiety. Several studies (n = 12 were assessed to have an unclear level of risk bias. The attrition levels ranged from 4% to 54% where the headache trials had the highest drop-out levels. However, findings suggest that internet-based treatments based on cognitive behavioural therapy (CBT are efficacious measured with different outcome variables. Results are in line with trials in clinical settings. Meta-analytic statistics were calculated for interference/disability, pain intensity, catastrophizing and mood ratings. Results showed that the effect size for interference/disability was Hedge's g = −0.39, for pain intensity Hedge's g = −0.33, for catastrophizing Hedge's g = −0.49 and for mood variables (depression Hedge's g = −0.26.

  5. Gait stability and variability measures show effects of impaired cognition and dual tasking in frail people

    Directory of Open Access Journals (Sweden)

    de Vries Oscar J

    2011-01-01

    Full Text Available Abstract Background Falls in frail elderly are a common problem with a rising incidence. Gait and postural instability are major risk factors for falling, particularly in geriatric patients. As walking requires attention, cognitive impairments are likely to contribute to an increased fall risk. An objective quantification of gait and balance ability is required to identify persons with a high tendency to fall. Recent studies have shown that stride variability is increased in elderly and under dual task condition and might be more sensitive to detect fall risk than walking speed. In the present study we complemented stride related measures with measures that quantify trunk movement patterns as indicators of dynamic balance ability during walking. The aim of the study was to quantify the effect of impaired cognition and dual tasking on gait variability and stability in geriatric patients. Methods Thirteen elderly with dementia (mean age: 82.6 ± 4.3 years and thirteen without dementia (79.4 ± 5.55 recruited from a geriatric day clinic, walked at self-selected speed with and without performing a verbal dual task. The Mini Mental State Examination and the Seven Minute Screen were administered. Trunk accelerations were measured with an accelerometer. In addition to walking speed, mean, and variability of stride times, gait stability was quantified using stochastic dynamical measures, namely regularity (sample entropy, long range correlations and local stability exponents of trunk accelerations. Results Dual tasking significantly (p Conclusions The observed trunk adaptations were a consistent instability factor. These results support the concept that changes in cognitive functions contribute to changes in the variability and stability of the gait pattern. Walking under dual task conditions and quantifying gait using dynamical parameters can improve detecting walking disorders and might help to identify those elderly who are able to adapt walking

  6. Universal Quantum Computing with Measurement-Induced Continuous-Variable Gate Sequence in a Loop-Based Architecture.

    Science.gov (United States)

    Takeda, Shuntaro; Furusawa, Akira

    2017-09-22

    We propose a scalable scheme for optical quantum computing using measurement-induced continuous-variable quantum gates in a loop-based architecture. Here, time-bin-encoded quantum information in a single spatial mode is deterministically processed in a nested loop by an electrically programmable gate sequence. This architecture can process any input state and an arbitrary number of modes with almost minimum resources, and offers a universal gate set for both qubits and continuous variables. Furthermore, quantum computing can be performed fault tolerantly by a known scheme for encoding a qubit in an infinite-dimensional Hilbert space of a single light mode.

  7. Identification of voltage stability condition of a power system using measurements of bus variables

    Directory of Open Access Journals (Sweden)

    Durlav Hazarika

    2014-12-01

    Full Text Available Several online methods were proposed for investigating the voltage stability condition of an interconnected power system using the measurements of voltage and current phasors at a bus. For this purpose, phasor measurement units (PMUs are used. A PMU is a device which measures the electrical waves on an electrical network, using a common time source (reference bus for synchronisation. This study proposes a method for online monitoring of voltage stability condition of a power system using measurements of bus variables namely – (i real power, (ii reactive power and (iii bus voltage magnitude at a bus. The measurements of real power, reactive power and bus voltage magnitude could be extracted/captured from a smart energy meter. The financial involvement for implementation of the proposed method would significantly lower compared with the PMU-based method.

  8. Measurements of reactive trace gases and variable O3 formation rates in some South Carolina biomass burning plumes

    Science.gov (United States)

    Akagi, S. K.; Yokelson, R. J.; Burling, I. R.; Meinardi, S.; Simpson, I.; Blake, D. R.; McMeeking, G. R.; Sullivan, A.; Lee, T.; Kreidenweis, S.; Urbanski, S.; Reardon, J.; Griffith, D. W. T.; Johnson, T. J.; Weise, D. R.

    2013-02-01

    In October-November 2011 we measured trace gas emission factors from seven prescribed fires in South Carolina (SC), US, using two Fourier transform infrared spectrometer (FTIR) systems and whole air sampling (WAS) into canisters followed by gas-chromatographic analysis. A total of 97 trace gas species were quantified from both airborne and ground-based sampling platforms, making this one of the most detailed field studies of fire emissions to date. The measurements include the first emission factors for a suite of monoterpenes produced by heating vegetative fuels during field fires. The first quantitative FTIR observations of limonene in smoke are reported along with an expanded suite of monoterpenes measured by WAS including α-pinene, β-pinene, limonene, camphene, 4-carene, and myrcene. The known chemistry of the monoterpenes and their measured abundance of 0.4-27.9% of non-methane organic compounds (NMOCs) and ~ 21% of organic aerosol (mass basis) suggests that they impacted secondary formation of ozone (O3), aerosols, and small organic trace gases such as methanol and formaldehyde in the sampled plumes in the first few hours after emission. The variability in the initial terpene emissions in the SC fire plumes was high and, in general, the speciation of the initially emitted gas-phase NMOCs was 13-195% different from that observed in a similar study in nominally similar pine forests in North Carolina ~ 20 months earlier. It is likely that differences in stand structure and environmental conditions contributed to the high variability observed within and between these studies. Similar factors may explain much of the variability in initial emissions in the literature. The ΔHCN/ΔCO emission ratio, however, was found to be fairly consistent with previous airborne fire measurements in other coniferous-dominated ecosystems, with the mean for these studies being 0.90 ± 0.06%, further confirming the value of HCN as a biomass burning tracer. The SC results also

  9. Putting the cart before the horse. A comment on Wagstaff on inequality measurement in the presence of binary variables

    NARCIS (Netherlands)

    G. Erreygers (Guido); T.G.M. van Ourti (Tom)

    2011-01-01

    textabstractAdam Wagstaff's (2011) recent paper sends a strong reminder that binary variables occur frequently in health inequality studies and that it is important to examine whether the standard measurement tools can be applied without any modification when the health variable happens to be

  10. Measurement Model Specification Error in LISREL Structural Equation Models.

    Science.gov (United States)

    Baldwin, Beatrice; Lomax, Richard

    This LISREL study examines the robustness of the maximum likelihood estimates under varying degrees of measurement model misspecification. A true model containing five latent variables (two endogenous and three exogenous) and two indicator variables per latent variable was used. Measurement model misspecification considered included errors of…

  11. Infrared Measurement Variability Analysis.

    Science.gov (United States)

    1980-09-01

    collecting optics of the measurement system. The first equation for tile blackbody experiment has the form 4.0 pim _ Ae W ,T) r(X,D) 3.5 pm - 4.0 pm JrD2 f3.5...potential for noise reduction by identifying and reducing contributing system effects. The measurement variance ott . of an infinite population of possible...irradiance can be written 4.0 pm I r()A A+ A ) 2 4.0 X C1(, = W(XT + AT)d 3.5 pim I since c + Af =2 r +Ar I Using the two expressions juSt devclopCd

  12. Concurrent variable-interval variable-ratio schedules in a dynamic choice environment.

    Science.gov (United States)

    Bell, Matthew C; Baum, William M

    2017-11-01

    Most studies of operant choice have focused on presenting subjects with a fixed pair of schedules across many experimental sessions. Using these methods, studies of concurrent variable- interval variable-ratio schedules helped to evaluate theories of choice. More recently, a growing literature has focused on dynamic choice behavior. Those dynamic choice studies have analyzed behavior on a number of different time scales using concurrent variable-interval schedules. Following the dynamic choice approach, the present experiment examined performance on concurrent variable-interval variable-ratio schedules in a rapidly changing environment. Our objectives were to compare performance on concurrent variable-interval variable-ratio schedules with extant data on concurrent variable-interval variable-interval schedules using a dynamic choice procedure and to extend earlier work on concurrent variable-interval variable-ratio schedules. We analyzed performances at different time scales, finding strong similarities between concurrent variable-interval variable-interval and concurrent variable-interval variable- ratio performance within dynamic choice procedures. Time-based measures revealed almost identical performance in the two procedures compared with response-based measures, supporting the view that choice is best understood as time allocation. Performance at the smaller time scale of visits accorded with the tendency seen in earlier research toward developing a pattern of strong preference for and long visits to the richer alternative paired with brief "samples" at the leaner alternative ("fix and sample"). © 2017 Society for the Experimental Analysis of Behavior.

  13. Using intraindividual variability to detect malingering in cognitive performance.

    Science.gov (United States)

    Strauss, E; Hultsch, D F; Hunter, M; Slick, D J; Patry, B; Levy-Bencheton, J

    1999-11-01

    The utility of measures for detecting malingering was evaluated using a simulation design in which half the participants were encouraged to do their best and half were asked to feign head injury. Particular attention was focused on the utility of repeated assessment (intraindividual variability) in discriminating the groups. Participants were tested on three occasions on measures commonly used to detect malingering including a specific symptom validity test (SVT). The results indicated that multiple measures of malingering obtained in single assessment (occasion one) discriminated the groups effectively. In addition, however, intraindividual variability in performance, particularly of indicators from the SVT, provided unique information beyond level of performance. The results suggest that response inconsistency across testing sessions may be a clinically useful measure for the detection of malingering.

  14. Stratospheric impact on tropospheric ozone variability and trends: 1990–2009

    Directory of Open Access Journals (Sweden)

    P. G. Hess

    2013-01-01

    Full Text Available The influence of stratospheric ozone on the interannual variability and trends in tropospheric ozone is evaluated between 30 and 90° N from 1990–2009 using ozone measurements and a global chemical transport model, the Community Atmospheric Model with chemistry (CAM-chem. Long-term measurements from ozonesondes, at 150 and 500 hPa, and the Measurements of OZone and water vapour by in-service Airbus aircraft programme (MOZAIC, at 500 hPa, are analyzed over Japan, Canada, the Eastern US and Northern and Central Europe. The measurements generally emphasize northern latitudes, although the simulation suggests that measurements over the Canadian, Northern and Central European regions are representative of the large-scale interannual ozone variability from 30 to 90° N at 500 hPa. CAM-chem is run with input meteorology from the National Center for Environmental Prediction; a tagging methodology is used to identify the stratospheric contribution to tropospheric ozone concentrations. A variant of the synthetic ozone tracer (synoz is used to represent stratospheric ozone. Both the model and measurements indicate that on large spatial scales stratospheric interannual ozone variability drives significant tropospheric variability at 500 hPa and the surface. In particular, the simulation and the measurements suggest large stratospheric influence at the surface sites of Mace Head (Ireland and Jungfraujoch (Switzerland as well as many 500 hPa measurement locations. Both the measurements and simulation suggest the stratosphere has contributed to tropospheric ozone trends. In many locations between 30–90° N 500 hPa ozone significantly increased from 1990–2000, but has leveled off since (from 2000–2009. The simulated global ozone budget suggests global stratosphere-troposphere exchange increased in 1998–1999 in association with a global ozone anomaly. Discrepancies between the simulated and measured ozone budget include a large underestimation of

  15. Measuring psychosocial variables that predict older persons' oral health behaviour.

    Science.gov (United States)

    Kiyak, H A

    1996-12-01

    The importance of recognising psychosocial characteristics of older people that influence their oral health behaviours and the potential success of dental procedures is discussed. Three variables and instruments developed and tested by the author and colleagues are presented. A measure of perceived importance of oral health behaviours has been found to be a significant predictor of dental service utilization in three studies. Self-efficacy regarding oral health has been found to be lower than self-efficacy regarding general health and medication use among older adults, especially among non-Western ethnic minorities. The significance of self-efficacy for predicting changes in caries and periodontal disease is described. Finally, a measure of expectations regarding specific dental procedures has been used with older people undergoing implant therapy. Studies with this instrument reveal that patients have concerns about the procedure far different than those focused on by dental providers. All three instruments can be used in clinical practice as a means of understanding patients' values, perceived oral health abilities, and expectations from dental care. These instruments can enhance dentist-patient rapport and improve the chances of successful dental outcomes for older patients.

  16. [Effects of situational and individual variables on critical thinking expression].

    Science.gov (United States)

    Tanaka, Yuko; Kusumi, Takashi

    2016-04-01

    The present study examined when people decide to choose an expression that is based on critical thinking, and how situational and individual variables affect such a decision process. Given a conversation scenario including overgeneralization with two friends, participants decided whether to follow the conversation by a critical-thinking expression or not. The authors controlled purpose and topic as situational variables, and measured critical-thinking ability, critical-thinking disposition, and self-monitoring as individual variables. We conducted an experiment in which the situational variables were counterbalanced in a within-subject design with 60 university students. The results of logistic regression analysis showed differences within individuals in the decision process whether to choose a critical-thinking expression, and that some situational factors and some subscales of the individual measurements were related to the differences.

  17. MEASURING X-RAY VARIABILITY IN FAINT/SPARSELY SAMPLED ACTIVE GALACTIC NUCLEI

    Energy Technology Data Exchange (ETDEWEB)

    Allevato, V. [Department of Physics, University of Helsinki, Gustaf Haellstroemin katu 2a, FI-00014 Helsinki (Finland); Paolillo, M. [Department of Physical Sciences, University Federico II, via Cinthia 6, I-80126 Naples (Italy); Papadakis, I. [Department of Physics and Institute of Theoretical and Computational Physics, University of Crete, 71003 Heraklion (Greece); Pinto, C. [SRON Netherlands Institute for Space Research, Sorbonnelaan 2, 3584-CA Utrecht (Netherlands)

    2013-07-01

    We study the statistical properties of the normalized excess variance of variability process characterized by a ''red-noise'' power spectral density (PSD), as in the case of active galactic nuclei (AGNs). We perform Monte Carlo simulations of light curves, assuming both a continuous and a sparse sampling pattern and various signal-to-noise ratios (S/Ns). We show that the normalized excess variance is a biased estimate of the variance even in the case of continuously sampled light curves. The bias depends on the PSD slope and on the sampling pattern, but not on the S/N. We provide a simple formula to account for the bias, which yields unbiased estimates with an accuracy better than 15%. We show that the normalized excess variance estimates based on single light curves (especially for sparse sampling and S/N < 3) are highly uncertain (even if corrected for bias) and we propose instead the use of an ''ensemble estimate'', based on multiple light curves of the same object, or on the use of light curves of many objects. These estimates have symmetric distributions, known errors, and can also be corrected for biases. We use our results to estimate the ability to measure the intrinsic source variability in current data, and show that they could also be useful in the planning of the observing strategy of future surveys such as those provided by X-ray missions studying distant and/or faint AGN populations and, more in general, in the estimation of the variability amplitude of sources that will result from future surveys such as Pan-STARRS and LSST.

  18. COMPARISON OF EXPERIMENTAL-DESIGNS COMBINING PROCESS AND MIXTURE VARIABLES .2. DESIGN EVALUATION ON MEASURED DATA

    NARCIS (Netherlands)

    DUINEVELD, C. A. A.; Smilde, A. K.; Doornbos, D. A.

    1993-01-01

    The construction of a small experimental design for a combination of process and mixture variables is a problem which has not been solved completely by now. In a previous paper we evaluated some designs with theoretical measures. This second paper evaluates the capabilities of the best of these

  19. COMPARISON OF EXPERIMENTAL-DESIGNS COMBINING PROCESS AND MIXTURE VARIABLES .2. DESIGN EVALUATION ON MEASURED DATA

    NARCIS (Netherlands)

    DUINEVELD, CAA; SMILDE, AK; DOORNBOS, DA

    The construction of a small experimental design for a combination of process and mixture variables is a problem which has not been solved completely by now. In a previous paper we evaluated some designs with theoretical measures. This second paper evaluates the capabilities of the best of these

  20. Using multiple biomarkers and determinants to obtain a better measurement of oxidative stress: a latent variable structural equation model approach.

    Science.gov (United States)

    Eldridge, Ronald C; Flanders, W Dana; Bostick, Roberd M; Fedirko, Veronika; Gross, Myron; Thyagarajan, Bharat; Goodman, Michael

    2017-09-01

    Since oxidative stress involves a variety of cellular changes, no single biomarker can serve as a complete measure of this complex biological process. The analytic technique of structural equation modeling (SEM) provides a possible solution to this problem by modelling a latent (unobserved) variable constructed from the covariance of multiple biomarkers. Using three pooled datasets, we modelled a latent oxidative stress variable from five biomarkers related to oxidative stress: F 2 -isoprostanes (FIP), fluorescent oxidation products, mitochondrial DNA copy number, γ-tocopherol (Gtoc) and C-reactive protein (CRP, an inflammation marker closely linked to oxidative stress). We validated the latent variable by assessing its relation to pro- and anti-oxidant exposures. FIP, Gtoc and CRP characterized the latent oxidative stress variable. Obesity, smoking, aspirin use and β-carotene were statistically significantly associated with oxidative stress in the theorized directions; the same exposures were weakly and inconsistently associated with the individual biomarkers. Our results suggest that using SEM with latent variables decreases the biomarker-specific variability, and may produce a better measure of oxidative stress than do single variables. This methodology can be applied to similar areas of research in which a single biomarker is not sufficient to fully describe a complex biological phenomenon.

  1. Universal continuous-variable quantum computation: Requirement of optical nonlinearity for photon counting

    International Nuclear Information System (INIS)

    Bartlett, Stephen D.; Sanders, Barry C.

    2002-01-01

    Although universal continuous-variable quantum computation cannot be achieved via linear optics (including squeezing), homodyne detection, and feed-forward, inclusion of ideal photon-counting measurements overcomes this obstacle. These measurements are sometimes described by arrays of beam splitters to distribute the photons across several modes. We show that such a scheme cannot be used to implement ideal photon counting and that such measurements necessarily involve nonlinear evolution. However, this requirement of nonlinearity can be moved ''off-line,'' thereby permitting universal continuous-variable quantum computation with linear optics

  2. Sensitivity to mental effort and test-retest reliability of heart rate variability measures in healthy seniors.

    Science.gov (United States)

    Mukherjee, Shalini; Yadav, Rajeev; Yung, Iris; Zajdel, Daniel P; Oken, Barry S

    2011-10-01

    To determine (1) whether heart rate variability (HRV) was a sensitive and reliable measure in mental effort tasks carried out by healthy seniors and (2) whether non-linear approaches to HRV analysis, in addition to traditional time and frequency domain approaches were useful to study such effects. Forty healthy seniors performed two visual working memory tasks requiring different levels of mental effort, while ECG was recorded. They underwent the same tasks and recordings 2 weeks later. Traditional and 13 non-linear indices of HRV including Poincaré, entropy and detrended fluctuation analysis (DFA) were determined. Time domain, especially mean R-R interval (RRI), frequency domain and, among non-linear parameters - Poincaré and DFA were the most reliable indices. Mean RRI, time domain and Poincaré were also the most sensitive to different mental effort task loads and had the largest effect size. Overall, linear measures were the most sensitive and reliable indices to mental effort. In non-linear measures, Poincaré was the most reliable and sensitive, suggesting possible usefulness as an independent marker in cognitive function tasks in healthy seniors. A large number of HRV parameters was both reliable as well as sensitive indices of mental effort, although the simple linear methods were the most sensitive. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Public transport travel time and its variability

    OpenAIRE

    Mazloumi Shomali, Ehsan

    2017-01-01

    Executive Summary Public transport agencies around the world are constantly trying to improve the performance of their service, and to provide passengers with a more reliable service. Two major measures to evaluate the performance of a transit system include travel time and travel time variability. Information on these two measures provides operators with a capacity to identify the problematic locations in a transport system and improve operating plans. Likewise, users can benefit through...

  4. The use of cognitive ability measures as explanatory variables in regression analysis.

    Science.gov (United States)

    Junker, Brian; Schofield, Lynne Steuerle; Taylor, Lowell J

    2012-12-01

    Cognitive ability measures are often taken as explanatory variables in regression analysis, e.g., as a factor affecting a market outcome such as an individual's wage, or a decision such as an individual's education acquisition. Cognitive ability is a latent construct; its true value is unobserved. Nonetheless, researchers often assume that a test score , constructed via standard psychometric practice from individuals' responses to test items, can be safely used in regression analysis. We examine problems that can arise, and suggest that an alternative approach, a "mixed effects structural equations" (MESE) model, may be more appropriate in many circumstances.

  5. IntelliGO: a new vector-based semantic similarity measure including annotation origin

    Directory of Open Access Journals (Sweden)

    Devignes Marie-Dominique

    2010-12-01

    Full Text Available Abstract Background The Gene Ontology (GO is a well known controlled vocabulary describing the biological process, molecular function and cellular component aspects of gene annotation. It has become a widely used knowledge source in bioinformatics for annotating genes and measuring their semantic similarity. These measures generally involve the GO graph structure, the information content of GO aspects, or a combination of both. However, only a few of the semantic similarity measures described so far can handle GO annotations differently according to their origin (i.e. their evidence codes. Results We present here a new semantic similarity measure called IntelliGO which integrates several complementary properties in a novel vector space model. The coefficients associated with each GO term that annotates a given gene or protein include its information content as well as a customized value for each type of GO evidence code. The generalized cosine similarity measure, used for calculating the dot product between two vectors, has been rigorously adapted to the context of the GO graph. The IntelliGO similarity measure is tested on two benchmark datasets consisting of KEGG pathways and Pfam domains grouped as clans, considering the GO biological process and molecular function terms, respectively, for a total of 683 yeast and human genes and involving more than 67,900 pair-wise comparisons. The ability of the IntelliGO similarity measure to express the biological cohesion of sets of genes compares favourably to four existing similarity measures. For inter-set comparison, it consistently discriminates between distinct sets of genes. Furthermore, the IntelliGO similarity measure allows the influence of weights assigned to evidence codes to be checked. Finally, the results obtained with a complementary reference technique give intermediate but correct correlation values with the sequence similarity, Pfam, and Enzyme classifications when compared to

  6. Measuring The Variability Of Gamma-Ray Sources With AGILE

    International Nuclear Information System (INIS)

    Chen, Andrew W.; Vercellone, Stefano; Pellizzoni, Alberto; Tavani, Marco

    2005-01-01

    Variability in the gamma-ray flux above 100 MeV at various time scales is one of the primary characteristics of the sources detected by EGRET, both allowing the identification of individual sources and constraining the unidentified source classes. We present a detailed simulation of the capacity of AGILE to characterize the variability of gamma-ray sources, discussing the implications for source population studies

  7. A Variable Impacts Measurement in Random Forest for Mobile Cloud Computing

    Directory of Open Access Journals (Sweden)

    Jae-Hee Hur

    2017-01-01

    Full Text Available Recently, the importance of mobile cloud computing has increased. Mobile devices can collect personal data from various sensors within a shorter period of time and sensor-based data consists of valuable information from users. Advanced computation power and data analysis technology based on cloud computing provide an opportunity to classify massive sensor data into given labels. Random forest algorithm is known as black box model which is hardly able to interpret the hidden process inside. In this paper, we propose a method that analyzes the variable impact in random forest algorithm to clarify which variable affects classification accuracy the most. We apply Shapley Value with random forest to analyze the variable impact. Under the assumption that every variable cooperates as players in the cooperative game situation, Shapley Value fairly distributes the payoff of variables. Our proposed method calculates the relative contributions of the variables within its classification process. In this paper, we analyze the influence of variables and list the priority of variables that affect classification accuracy result. Our proposed method proves its suitability for data interpretation in black box model like a random forest so that the algorithm is applicable in mobile cloud computing environment.

  8. Variations in Carabidae assemblages across the farmland habitats in relation to selected environmental variables including soil properties

    Directory of Open Access Journals (Sweden)

    Beáta Baranová

    2018-03-01

    Full Text Available The variations in ground beetles (Coleoptera: Carabidae assemblages across the three types of farmland habitats, arable land, meadows and woody vegetation were studied in relation to vegetation cover structure, intensity of agrotechnical interventions and selected soil properties. Material was pitfall trapped in 2010 and 2011 on twelve sites of the agricultural landscape in the Prešov town and its near vicinity, Eastern Slovakia. A total of 14,763 ground beetle individuals were entrapped. Material collection resulted into 92 Carabidae species, with the following six species dominating: Poecilus cupreus, Pterostichus melanarius, Pseudoophonus rufipes, Brachinus crepitans, Anchomenus dorsalis and Poecilus versicolor. Studied habitats differed significantly in the number of entrapped individuals, activity abundance as well as representation of the carabids according to their habitat preferences and ability to fly. However, no significant distinction was observed in the diversity, evenness neither dominance. The most significant environmental variables affecting Carabidae assemblages species variability were soil moisture and herb layer 0-20 cm. Another best variables selected by the forward selection were intensity of agrotechnical interventions, humus content and shrub vegetation. The other from selected soil properties seem to have just secondary meaning for the adult carabids. Environmental variables have the strongest effect on the habitat specialists, whereas ground beetles without special requirements to the habitat quality seem to be affected by the studied environmental variables just little.

  9. Effectiveness of Variable-Gain Kalman Filter Based on Angle Error Calculated from Acceleration Signals in Lower Limb Angle Measurement with Inertial Sensors

    Science.gov (United States)

    Watanabe, Takashi

    2013-01-01

    The wearable sensor system developed by our group, which measured lower limb angles using Kalman-filtering-based method, was suggested to be useful in evaluation of gait function for rehabilitation support. However, it was expected to reduce variations of measurement errors. In this paper, a variable-Kalman-gain method based on angle error that was calculated from acceleration signals was proposed to improve measurement accuracy. The proposed method was tested comparing to fixed-gain Kalman filter and a variable-Kalman-gain method that was based on acceleration magnitude used in previous studies. First, in angle measurement in treadmill walking, the proposed method measured lower limb angles with the highest measurement accuracy and improved significantly foot inclination angle measurement, while it improved slightly shank and thigh inclination angles. The variable-gain method based on acceleration magnitude was not effective for our Kalman filter system. Then, in angle measurement of a rigid body model, it was shown that the proposed method had measurement accuracy similar to or higher than results seen in other studies that used markers of camera-based motion measurement system fixing on a rigid plate together with a sensor or on the sensor directly. The proposed method was found to be effective in angle measurement with inertial sensors. PMID:24282442

  10. Monitoring and measurement of variables - assurance of observability and controllability of the reactor equipment

    International Nuclear Information System (INIS)

    Durnev, V.N.; Mitelman, M.G.

    2001-01-01

    The presentation presents main conclusions on the basis of analysis of the existing situation with assurance of observability and controllability of the reactor installation. A methodology of classification of variables of the controlled object state and proposals on selection and substantiation of measurement and inspection monitoring techniques is given. Main problems associated with assurance of observability and controllability of the reactor installation are presented for various operation modes. (Authors)

  11. Intra-individual variability in day-to-day and month-to-month measurements of physical activity and sedentary behaviour at work and in leisure-time among Danish adults.

    Science.gov (United States)

    Pedersen, E S L; Danquah, I H; Petersen, C B; Tolstrup, J S

    2016-12-03

    Accelerometers can obtain precise measurements of movements during the day. However, the individual activity pattern varies from day-to-day and there is limited evidence on measurement days needed to obtain sufficient reliability. The aim of this study was to examine variability in accelerometer derived data on sedentary behaviour and physical activity at work and in leisure-time during week days among Danish office employees. We included control participants (n = 135) from the Take a Stand! Intervention; a cluster randomized controlled trial conducted in 19 offices. Sitting time and physical activity were measured using an ActiGraph GT3X+ fixed on the thigh and data were processed using Acti4 software. Variability was examined for sitting time, standing time, steps and time spent in moderate-to-vigorous physical activity (MVPA) per day by multilevel mixed linear regression modelling. Results of this study showed that the number of days needed to obtain a reliability of 80% when measuring sitting time was 4.7 days for work and 5.5 days for leisure time. For physical activity at work, 4.0 days and 4.2 days were required to measure steps and MVPA, respectively. During leisure time, more monitoring time was needed to reliably estimate physical activity (6.8 days for steps and 5.8 days for MVPA). The number of measurement days needed to reliably estimate activity patterns was greater for leisure time than for work time. The domain specific variability is of great importance to researchers and health promotion workers planning to use objective measures of sedentary behaviour and physical activity. Clinical trials NCT01996176 .

  12. Intra and interobserver variability of renal allograft ultrasound volume and resistive index measurements

    International Nuclear Information System (INIS)

    Mancini, Marcello; Liuzzi, Raffaele; Daniele, Stefania; Raffio, Teresa; Salvatore, Marco; Sabbatini, Massimo; Cianciaruso, Bruno; Ferrara, Liberato Aldo

    2005-01-01

    Purpose: Aim of the presents study was to evaluate the repeatability and reproducibility of the Doppler Resistive Index (R.I.) and the Ultrasound renal volume measurement in renal transplants. Materials and methods: Twenty -six consecutive patients (18 men, 8 women) mean age of 42,8±12,4 years (M±SD)(range 22-65 years) were studied twice by each of two trained sonographers using a color Doppler ultrasound scanner. Twelve of them had a normal allograft function (defined as stable serum creatinine levels ≤123,76 μmol/L), whilst the remaining 14 had decreased allograft function (serum creatinine 132.6-265.2 μmol/L). Results were given as mean of 6 measurements performed at upper, middle and lower pole of the kidney. Intra- and interobserver variability was assessed by the repeatability coefficient and coefficient of variation (CV). Results: Regarding Resistive Index measurement, repeatability coefficient was between 0.04 and 0.06 and the coefficient of variation was [it

  13. Validity of (Ultra-Short Recordings for Heart Rate Variability Measurements.

    Directory of Open Access Journals (Sweden)

    M Loretto Munoz

    Full Text Available In order to investigate the applicability of routine 10s electrocardiogram (ECG recordings for time-domain heart rate variability (HRV calculation we explored to what extent these (ultra-short recordings capture the "actual" HRV.The standard deviation of normal-to-normal intervals (SDNN and the root mean square of successive differences (RMSSD were measured in 3,387 adults. SDNN and RMSSD were assessed from (ultrashort recordings of 10s(3x, 30s, and 120s and compared to 240s-300s (gold standard measurements. Pearson's correlation coefficients (r, Bland-Altman 95% limits of agreement and Cohen's d statistics were used as agreement analysis techniques.Agreement between the separate 10s recordings and the 240s-300s recording was already substantial (r = 0.758-0.764/Bias = 0.398-0.416/d = 0.855-0.894 for SDNN; r = 0.853-0.862/Bias = 0.079-0.096/d = 0.150-0.171 for RMSSD, and improved further when three 10s periods were averaged (r = 0.863/Bias = 0.406/d = 0.874 for SDNN; r = 0.941/Bias = 0.088/d = 0.167 for RMSSD. Agreement increased with recording length and reached near perfect agreement at 120s (r = 0.956/Bias = 0.064/d = 0.137 for SDNN; r = 0.986/Bias = 0.014/d = 0.027 for RMSSD. For all recording lengths and agreement measures, RMSSD outperformed SDNN.Our results confirm that it is unnecessary to use recordings longer than 120s to obtain accurate measures of RMSSD and SDNN in the time domain. Even a single 10s (standard ECG recording yields a valid RMSSD measurement, although an average over multiple 10s ECGs is preferable. For SDNN we would recommend either 30s or multiple 10s ECGs. Future research projects using time-domain HRV parameters, e.g. genetic epidemiological studies, could calculate HRV from (ultra-short ECGs enabling such projects to be performed at a large scale.

  14. Capturing Dynamics of Biased Attention: Are New Attention Variability Measures the Way Forward?

    Directory of Open Access Journals (Sweden)

    Anne-Wil Kruijt

    Full Text Available New indices, calculated on data from the widely used Dot Probe Task, were recently proposed to capture variability in biased attention allocation. We observed that it remains unclear which data pattern is meant to be indicative of dynamic bias and thus to be captured by these indices. Moreover, we hypothesized that the new indices are sensitive to SD differences at the response time (RT level in the absence of bias.Randomly generated datasets were analyzed to assess properties of the Attention Bias Variability (ABV and Trial Level Bias Score (TL-BS indices. Sensitivity to creating differences in 1 RT standard deviation, 2 mean RT, and 3 bias magnitude were assessed. In addition, two possible definitions of dynamic attention bias were explored by creating differences in 4 frequency of bias switching, and 5 bias magnitude in the presence of constant switching.ABV and TL-BS indices were found highly sensitive to increasing SD at the response time level, insensitive to increasing bias, linearly sensitive to increasing bias magnitude in the presence of bias switches, and non-linearly sensitive to increasing the frequency of bias switches. The ABV index was also found responsive to increasing mean response times in the absence of bias.Recently proposed DPT derived variability indices cannot uncouple measurement error from bias variability. Significant group differences may be observed even if there is no bias present in any individual dataset. This renders the new indices in their current form unfit for empirical purposes. Our discussion focuses on fostering debate and ideas for new research to validate the potentially very important notion of biased attention being dynamic.

  15. Essentials aspects on macroeconomic variables and their correlations

    OpenAIRE

    Constantin ANGHELACHE; Alexandru MANOLE; Mădălina Gabriela ANGHEL; Aurelian DIACONU

    2016-01-01

    The measurement of the correlations between macroeconomic variables, including the cause-effect links, provide useful information for policy makers in the government and public agencies. Especially important is the system of relationships that reveals the influence of certain factors on the Gross Domestic Product. This paper outlines the influence of the unemployment, measured through the unemployment rate, the inflation. Also, the authors discuss the correlations of the econom...

  16. Continuous-variable measurement-device-independent quantum key distribution with photon subtraction

    Science.gov (United States)

    Ma, Hong-Xin; Huang, Peng; Bai, Dong-Yun; Wang, Shi-Yu; Bao, Wan-Su; Zeng, Gui-Hua

    2018-04-01

    It has been found that non-Gaussian operations can be applied to increase and distill entanglement between Gaussian entangled states. We show the successful use of the non-Gaussian operation, in particular, photon subtraction operation, on the continuous-variable measurement-device-independent quantum key distribution (CV-MDI-QKD) protocol. The proposed method can be implemented based on existing technologies. Security analysis shows that the photon subtraction operation can remarkably increase the maximal transmission distance of the CV-MDI-QKD protocol, which precisely make up for the shortcoming of the original CV-MDI-QKD protocol, and one-photon subtraction operation has the best performance. Moreover, the proposed protocol provides a feasible method for the experimental implementation of the CV-MDI-QKD protocol.

  17. Development of a time-variable nuclear pulser for half life measurements

    International Nuclear Information System (INIS)

    Zahn, Guilherme S.; Domienikan, Claudio; Carvalhaes, Roberto P. M.; Genezini, Frederico A.

    2013-01-01

    In this work a time-variable pulser system with an exponentially-decaying pulse frequency is presented, which was developed using the low-cost, open-source Arduino microcontroler plataform. In this system, the microcontroller produces a TTL signal in the selected rate and a pulse shaper board adjusts it to be entered in an amplifier as a conventional pulser signal; both the decay constant and the initial pulse rate can be adjusted using a user-friendly control software, and the pulse amplitude can be adjusted using a potentiometer in the pulse shaper board. The pulser was tested using several combinations of initial pulse rate and decay constant, and the results show that the system is stable and reliable, and is suitable to be used in half-life measurements.

  18. Development of a time-variable nuclear pulser for half life measurements

    Energy Technology Data Exchange (ETDEWEB)

    Zahn, Guilherme S.; Domienikan, Claudio; Carvalhaes, Roberto P. M.; Genezini, Frederico A. [Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP. P.O. Box 11049, Sao Paulo, 05422-970 (Brazil)

    2013-05-06

    In this work a time-variable pulser system with an exponentially-decaying pulse frequency is presented, which was developed using the low-cost, open-source Arduino microcontroler plataform. In this system, the microcontroller produces a TTL signal in the selected rate and a pulse shaper board adjusts it to be entered in an amplifier as a conventional pulser signal; both the decay constant and the initial pulse rate can be adjusted using a user-friendly control software, and the pulse amplitude can be adjusted using a potentiometer in the pulse shaper board. The pulser was tested using several combinations of initial pulse rate and decay constant, and the results show that the system is stable and reliable, and is suitable to be used in half-life measurements.

  19. Understanding Spatiotemporal Variability of Fine Particulate Matter in an Urban Environment Using Combined Fixed and Mobile Measurements

    Science.gov (United States)

    Sullivan, R.; Pryor, S. C.; Barthelmie, R. J.; Filippelli, G. M.

    2013-12-01

    Acute and chronic exposure to elevated levels of aerosol particles represents a well-documented threat to public health. This is especially true in urban areas where in situ emissions elevate concentrations above regional background levels and population density is high, exposing a greater number of people to unhealthy air. The EPA's evaluation of compliance with National Ambient Air Quality Standards (NAAQS) for ambient fine particle (PM 2.5) concentrations in a city is frequently based on a limited number of observing stations and daily average concentrations. For example, data from only three locations indicates that Indianapolis (a city of nearly 1 million people) fails the NAAQS for PM2.5. However, the true population exposure exhibits spatial and temporal variability and thus is not adequately represented by long-term measurements. Thus, since 2011 we have conducted additional highly time-resolved PM2.5 measurements at four additional stations within Indianapolis. Analyses of these data indicate: ● PM2.5 concentrations in the city are an average of over 4 micrograms per cubic meter above a non-urban regionally representative site. ● A distinct diurnal cycle of PM2.5 concentrations in the city with a daily maximum in concentrations and higher outliers typically occurring during the morning hours (approx. 0700-0900 LST) and a daily minimum in concentrations and fewer outliers occurring in the afternoon (approx. 1400-1800 LST). ● Highest concentrations typically occur during weekdays. This hebdomadal pattern was amplified in proximity to the main interstate junction through the center of the city. ● PM2.5 concentrations thus exhibit similar timescales of variability to carbon monoxide, of which over 90% derives from the mobile sector, indicating a strong signature from motor vehicles. An additional mode of variability in PM2.5 as observed in power spectra equates to synoptic time scales (four days up to two weeks). ● On average wind speeds during

  20. Self-referenced continuous-variable measurement-device-independent quantum key distribution

    Science.gov (United States)

    Wang, Yijun; Wang, Xudong; Li, Jiawei; Huang, Duan; Zhang, Ling; Guo, Ying

    2018-05-01

    We propose a scheme to remove the demand of transmitting a high-brightness local oscillator (LO) in continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol, which we call as the self-referenced (SR) CV-MDI QKD. We show that our scheme is immune to the side-channel attacks, such as the calibration attacks, the wavelength attacks and the LO fluctuation attacks, which are all exploiting the security loopholes introduced by transmitting the LO. Besides, the proposed scheme waives the necessity of complex multiplexer and demultiplexer, which can greatly simplify the QKD processes and improve the transmission efficiency. The numerical simulations under collective attacks show that all the improvements brought about by our scheme are only at the expense of slight transmission distance shortening. This scheme shows an available method to mend the security loopholes incurred by transmitting LO in CV-MDI QKD.

  1. Association between the extent of urinary albumin excretion and glycaemic variability indices measured by continuous glucose monitoring.

    Science.gov (United States)

    Jin, S-M; Kim, T-H; Oh, S; Baek, J; Joung, J Y; Park, S-M; Cho, Y Y; Sohn, S Y; Hur, K Y; Lee, M-S; Lee, M-K; Kim, J H

    2015-02-01

    The contribution of glycaemic variability to the microvascular complication of diabetes has not been established. We examined whether there is an independent association between indices of glycaemic variability in continuous glucose monitoring and extent of albuminuria. A total of 173 patients with Type 2 diabetes (without insulin therapy, n = 96; with insulin therapy, n = 77) who had unexplained large fluctuations in blood glucose values underwent three-day continuous glucose monitoring. We used a multinomial logistic regression model to determine whether the indices of glycaemic variability independently affected the odds of having a spot urine albumin/creatinine ratio of 30-299 mg/g and ≥ 300 mg/g. Higher standard deviation (P = 0.002), mean of daily differences (P = 0.023) and mean amplitude of glycaemic excursion (P = 0.043) significantly increased the odds of having a urine albumin/creatinine ratio of ≥ 300 mg/g. In multivariable analysis, only higher standard deviation, but not mean amplitude of glycaemic excursion and mean of daily differences, independently increased the odds of having a urine albumin/creatinine ratio of ≥ 300 mg/g (P = 0.025). Coefficient of variation (sd/mean) was not associated with the odds of having a urine albumin/creatinine ratio of 30-299 or ≥ 300 mg/g. The independent association between standard deviation and the extent of albuminuria was lost when the measures were normalized by mean glucose level. At least in terms of relative measures of glycaemic variability, we failed to demonstrate an independent association between glycaemic variability and albuminuria extent in patients with inadequately controlled Type 2 diabetes. © 2014 The Authors. Diabetic Medicine © 2014 Diabetes UK.

  2. Fatigue Behavior under Multiaxial Stress States Including Notch Effects and Variable Amplitude Loading

    Science.gov (United States)

    Gates, Nicholas R.

    The central objective of the research performed in this study was to be able to better understand and predict fatigue crack initiation and growth from stress concentrations subjected to complex service loading histories. As such, major areas of focus were related to the understanding and modeling of material deformation behavior, fatigue damage quantification, notch effects, cycle counting, damage accumulation, and crack growth behavior under multiaxial nominal loading conditions. To support the analytical work, a wide variety of deformation and fatigue tests were also performed using tubular and plate specimens made from 2024-T3 aluminum alloy, with and without the inclusion of a circular through-thickness hole. However, the analysis procedures implemented were meant to be general in nature, and applicable to a wide variety of materials and component geometries. As a result, experimental data from literature were also used, when appropriate, to supplement the findings of various analyses. Popular approaches currently used for multiaxial fatigue life analysis are based on the idea of computing an equivalent stress/strain quantity through the extension of static yield criteria. This equivalent stress/strain is then considered to be equal, in terms of fatigue damage, to a uniaxial loading of the same magnitude. However, it has often been shown, and was shown again in this study, that although equivalent stress- and strain-based analysis approaches may work well in certain situations, they lack a general robustness and offer little room for improvement. More advanced analysis techniques, on the other hand, provide an opportunity to more accurately account for various aspects of the fatigue failure process under both constant and variable amplitude loading conditions. As a result, such techniques were of primary interest in the investigations performed. By implementing more advanced life prediction methodologies, both the overall accuracy and the correlation of fatigue

  3. Exploring intra- and inter-reader variability in uni-dimensional, bi-dimensional, and volumetric measurements of solid tumors on CT scans reconstructed at different slice intervals

    International Nuclear Information System (INIS)

    Zhao, Binsheng; Tan, Yongqiang; Bell, Daniel J.; Marley, Sarah E.; Guo, Pingzhen; Mann, Helen; Scott, Marietta L.J.; Schwartz, Lawrence H.; Ghiorghiu, Dana C.

    2013-01-01

    Objective: Understanding magnitudes of variability when measuring tumor size may be valuable in improving detection of tumor change and thus evaluating tumor response to therapy in clinical trials and care. Our study explored intra- and inter-reader variability of tumor uni-dimensional (1D), bi-dimensional (2D), and volumetric (VOL) measurements using manual and computer-aided methods (CAM) on CT scans reconstructed at different slice intervals. Materials and methods: Raw CT data from 30 patients enrolled in oncology clinical trials was reconstructed at 5, 2.5, and 1.25 mm slice intervals. 118 lesions in the lungs, liver, and lymph nodes were analyzed. For each lesion, two independent radiologists manually and, separately, using computer software, measured the maximum diameter (1D), maximum perpendicular diameter, and volume (CAM only). One of them blindly repeated the measurements. Intra- and inter-reader variability for the manual method and CAM were analyzed using linear mixed-effects models and Bland–Altman method. Results: For the three slice intervals, the maximum coefficients of variation for manual intra-/inter-reader variability were 6.9%/9.0% (1D) and 12.3%/18.0% (2D), and for CAM were 5.4%/9.3% (1D), 11.3%/18.8% (2D) and 9.3%/18.0% (VOL). Maximal 95% reference ranges for the percentage difference in intra-reader measurements for manual 1D and 2D, and CAM VOL were (−15.5%, 25.8%), (−27.1%, 51.6%), and (−22.3%, 33.6%), respectively. Conclusions: Variability in measuring the diameter and volume of solid tumors, manually and by CAM, is affected by CT slice interval. The 2.5 mm slice interval provides the least measurement variability. Among the three techniques, 2D has the greatest measurement variability compared to 1D and 3D

  4. Does glycemic variability impact mood and quality of life?

    Science.gov (United States)

    Penckofer, Sue; Quinn, Lauretta; Byrn, Mary; Ferrans, Carol; Miller, Michael; Strange, Poul

    2012-04-01

    Diabetes is a chronic condition that significantly impacts quality of life. Poor glycemic control is associated with more diabetes complications, depression, and worse quality of life. The impact of glycemic variability on mood and quality of life has not been studied. A descriptive exploratory design was used. Twenty-three women with type 2 diabetes wore a continuous glucose monitoring system for 72 h and completed a series of questionnaires. Measurements included (1) glycemic control shown by glycated hemoglobin and 24-h mean glucose, (2) glycemic variability shown by 24-h SD of the glucose readings, continuous overall net glycemic action (CONGA), and Fourier statistical models to generate smoothed curves to assess rate of change defined as "energy," and (3) mood (depression, anxiety, anger) and quality of life by questionnaires. Women with diabetes and co-morbid depression had higher anxiety, more anger, and lower quality of life than those without depression. Certain glycemic variability measures were associated with mood and quality of life. The 24-h SD of the glucose readings and the CONGA measures were significantly associated with health-related quality of life after adjusting for age and weight. Fourier models indicated that certain energy components were significantly associated with depression, trait anxiety, and overall quality of life. Finally, subjects with higher trait anxiety tended to have steeper glucose excursions. Data suggest that greater glycemic variability may be associated with lower quality of life and negative moods. Implications include replication of the study in a larger sample for the assessment of blood glucose fluctuations as they impact mood and quality of life.

  5. BLAZAR OPTICAL VARIABILITY IN THE PALOMAR-QUEST SURVEY

    International Nuclear Information System (INIS)

    Bauer, Anne; Baltay, Charles; Coppi, Paolo; Ellman, Nancy; Jerke, Jonathan; Rabinowitz, David; Scalzo, Richard

    2009-01-01

    We study the ensemble optical variability of 276 flat-spectrum radio quasars (FSRQs) and 86 BL Lacs in the Palomar-QUEST Survey with the goal of searching for common fluctuation properties, examining the range of behavior across the sample, and characterizing the appearance of blazars in such a survey so that future work can more easily identify such objects. The survey, which covers 15,000 deg 2 multiple times over 3.5 years, allows for the first ensemble blazar study of this scale. Variability amplitude distributions are shown for the FSRQ and BL Lac samples for numerous time lags, and also studied through structure function analyses. Individual blazars show a wide range of variability amplitudes, timescales, and duty cycles. Of the best-sampled objects, 35% are seen to vary by more than 0.4 mag; for these, the fraction of measurements contributing to the high-amplitude variability ranges constantly from about 5% to 80%. Blazar variability has some similarities to that of type I quasi-stellar objects (QSOs) but includes larger amplitude fluctuations on all timescales. FSRQ variability amplitudes are particularly similar to those of QSOs on timescales of several months, suggesting significant contributions from the accretion disk to the variable flux at these timescales. Optical variability amplitudes are correlated with the maximum apparent velocities of the radio jet for the subset of FSRQs with MOJAVE Very Long Baseline Array measurements, implying that the optically variable flux's strength is typically related to that of the radio emission. We also study CRATES radio-selected FSRQ candidates, which show similar variability characteristics to known FSRQs; this suggests a high purity for the CRATES sample.

  6. Intra- and interobserver variability of thyroid volume measurements in healthy adults by 2D versus 3D ultrasound

    International Nuclear Information System (INIS)

    Andermann, P.; Schloegl, S.; Maeder, U.; Luster, M.; Lassmann, M.; Reiners, C.

    2007-01-01

    Thyroid volume measurement by ultrasonography (US) is essential in numerous clinical diagnostic and therapeutic fields. While known to be limited, the accuracy and precision of two-dimensional (2D) US thyroid volume measurement have not been thoroughly characterized. Objective: We sought to assess the intra- and interobserver variability, accuracy and precision of thyroid volume determination by conventional 2D US in healthy adults using reference volumes determined by three-dimensional (3D) US. Design, methods: In a prospective blinded trial, thyroid volumes of ten volunteers were determined repeatedly by nine experienced sonographers using conventional 2D US (ellipsoid model). The values obtained were statistically compared to the so-called true volumes determined by 3D US (multiplanar approximation), the so-called gold standard, to estimate systematic errors and relative deviations of individual observers. Results: The standard error of measurement (SEM) for one observer and successive measurements (intraobserver variability), was 14%, and for different observers and repeated measurements (interobserver variability), 17%. The minimum relative thyroid volume change significantly different at the 95% level was 39% for the same observer and 46% for different observers. Regarding accuracy, the mean value of the differences showed a significant thyroid volume overestimation (17%, p <0.01) by 2D relative to 3D US. Conclusion: 2D US is appropriate for routine thyroid volumetry. Nevertheless, the so-called human factor (random error) should be kept in mind and correction is needed for methodical bias (systematic error). Further efforts are required to improve the accuracy and precision of 2D US thyroid volumetry by optimizing the underlying geometrical modeling or by the application of 3D US. (orig.)

  7. O(α2L2) radiative corrections to deep inelastic ep scattering for different kinematical variables

    International Nuclear Information System (INIS)

    Bluemlein, J.

    1994-03-01

    The QED radiative corrections are calculated in the leading log approximation up to O(α 2 ) for different definitions of the kinematical variables using jet measurement, the 'mixed' variables, the double angle method, and a measurement based on θ e and y JB . Higher order contributions due to exponentiation of soft radiation are included. (orig.)

  8. Astronaut Preflight Cardiovascular Variables Associated with Vascular Compliance are Highly Correlated with Post-Flight Eye Outcome Measures in the Visual Impairment Intracranial Pressure (VIIP) Syndrome Following Long Duration Spaceflight

    Science.gov (United States)

    Otto, Christian; Ploutz-Snyder, R.

    2015-01-01

    The detection of the first VIIP case occurred in 2005, and adequate eye outcome measures were available for 31 (67.4%) of the 46 long duration US crewmembers who had flown on the ISS since its first crewed mission in 2000. Therefore, this analysis is limited to a subgroup (22 males and 9 females). A "cardiovascular profile" for each astronaut was compiled by examining twelve individual parameters; eleven of these were preflight variables: systolic blood pressure, pulse pressure, body mass index, percentage body fat, LDL, HDL, triglycerides, use of anti-lipid medication, fasting serum glucose, and maximal oxygen uptake in ml/kg. Each of these variables was averaged across three preflight annual physical exams. Astronaut age prior to the long duration mission, and inflight salt intake was also included in the analysis. The group of cardiovascular variables for each crew member was compared with seven VIIP eye outcome variables collected during the immediate post-flight period: anterior-posterior axial length of the globe measured by ultrasound and optical biometry; optic nerve sheath diameter, optic nerve diameter, and optic nerve to sheath ratio- each measured by ultrasound and magnetic resonance imaging (MRI), intraocular pressure (IOP), change in manifest refraction, mean retinal nerve fiber layer (RNFL) on optical coherence tomography (OCT), and RNFL of the inferior and superior retinal quadrants. Since most of the VIIP eye outcome measures were added sequentially beginning in 2005, as knowledge of the syndrome improved, data were unavailable for 22.0% of the outcome measurements. To address the missing data, we employed multivariate multiple imputation techniques with predictive mean matching methods to accumulate 200 separate imputed datasets for analysis. We were able to impute data for the 22.0% of missing VIIP eye outcomes. We then applied Rubin's rules for collapsing the statistical results across our 200 multiply imputed data sets to assess the canonical

  9. Measurements of reactive trace gases and variable O3 formation rates in some South Carolina biomass burning plumes

    Energy Technology Data Exchange (ETDEWEB)

    Akagi, S. K.; Yokelson, R. J.; Burling, I. R.; Meinardi, S.; Simpson, I.; Blake, D. R.; McMeeking, G. R.; Sullivan, A.; Lee, T.; Kreidenweis, S.; Urbanski, S.; Reardon, J.; Griffith, D. W. T.; Johnson, T. J.; Weise, D. R.

    2013-02-01

    In October-November 2011 we measured the trace gas emission factors from 7 prescribed fires in South Carolina, U.S. using two Fourier transform infrared spectrometer (FTIR) systems and whole air sampling (WAS) into canisters followed by gas-chromatographic analyses. The fires were intended to emulate high-intensity burns as they were lit during the dry season and in most cases represented stands that had not been treated with prescribed burns in 10+ years, if at all. A total of 97 trace gas species are reported here from both airborne and ground-based platforms making this one of the most detailed field studies of fire emissions to date. The measurements included the first data for a suite of monoterpene compounds emitted via distillation of plant tissues during real fires. The known chemistry of the monoterpenes and their measured abundance of ~0.40% of CO (molar basis), ~3.9% of NMOC (molar basis), and ~21% of organic aerosol (mass basis), suggests that they impacted post-emission formation of ozone, aerosol, and small organic trace gases such as methanol and formaldehyde in the sampled plumes. The variability in the terpene emissions in South Carolina (SC) fire plumes was high and, in general, the speciation of the emitted gas-phase non-methane organic compounds was surprisingly different from that observed in a similar study in nominally similar pine forests in North Carolina ~20 months earlier. It is likely that the slightly different ecosystems, time of year and the precursor variability all contributed to the variability in plume chemistry observed in this study and in the literature. The ΔHCN/ΔCO emission ratio, however, is fairly consistent at 0.9 ± 0.06 % for airborne fire measurements in coniferous-dominated ecosystems further confirming the value of HCN as a good biomass burning indicator/tracer. The SC results also support an earlier finding that C3-C4 alkynes may be of use as biomass burning indicators on the time-scale of

  10. Three-dimensional echocardiography: assessment of inter- and intra-operator variability and accuracy in the measurement of left ventricular cavity volume and myocardial mass

    International Nuclear Information System (INIS)

    Nadkarni, S.K.; Drangova, M.; Boughner, D.R.; Fenster, A.; Department of Medical Biophysics, Medical Sciences Building, University of Western Ontario, London, Ontario N6A 5C1

    2000-01-01

    Accurate left ventricular (LV) volume and mass estimation is a strong predictor of cardiovascular morbidity and mortality. We propose that our technique of 3D echocardiography provides an accurate quantification of LV volume and mass by the reconstruction of 2D images into 3D volumes, thus avoiding the need for geometric assumptions. We compared the accuracy and variability in LV volume and mass measurement using 3D echocardiography with 2D echocardiography, using in vitro studies. Six operators measured the LV volume and mass of seven porcine hearts, using both 3D and 2D techniques. Regression analysis was used to test the accuracy of results and an ANOVA test was used to compute variability in measurement. LV volume measurement accuracy was 9.8% (3D) and 18.4% (2D); LV mass measurement accuracy was 5% (3D) and 9.2% (2D). Variability in LV volume quantification with 3D echocardiography was %SEM inter = 13.5%, %SEM intra = 11.4%, and for 2D echocardiography was %SEM inter = 21.5%, %SEM intra = 19.1%. We derived an equation to predict uncertainty in measurement of LV volume and mass using 3D echocardiography, the results of which agreed with our experimental results to within 13%. 3D echocardiography provided twice the accuracy for LV volume and mass measurement and half the variability for LV volume measurement as compared with 2D echocardiography. (author)

  11. Diagnostic for two-mode variable valve activation device

    Science.gov (United States)

    Fedewa, Andrew M

    2014-01-07

    A method is provided for diagnosing a multi-mode valve train device which selectively provides high lift and low lift to a combustion valve of an internal combustion engine having a camshaft phaser actuated by an electric motor. The method includes applying a variable electric current to the electric motor to achieve a desired camshaft phaser operational mode and commanding the multi-mode valve train device to a desired valve train device operational mode selected from a high lift mode and a low lift mode. The method also includes monitoring the variable electric current and calculating a first characteristic of the parameter. The method also includes comparing the calculated first characteristic against a predetermined value of the first characteristic measured when the multi-mode valve train device is known to be in the desired valve train device operational mode.

  12. Including health insurance in poverty measurement: The impact of Massachusetts health reform on poverty.

    Science.gov (United States)

    Korenman, Sanders D; Remler, Dahlia K

    2016-12-01

    We develop and implement what we believe is the first conceptually valid health-inclusive poverty measure (HIPM) - a measure that includes health care or insurance in the poverty needs threshold and health insurance benefits in family resources - and we discuss its limitations. Building on the Census Bureau's Supplemental Poverty Measure, we construct a pilot HIPM for the under-65 population under ACA-like health reform in Massachusetts. This pilot demonstrates the practicality, face validity and value of a HIPM. Results suggest that public health insurance benefits and premium subsidies accounted for a substantial, one-third reduction in the health inclusive poverty rate. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Auxiliary variables in multiple imputation in regression with missing X: a warning against including too many in small sample research

    Directory of Open Access Journals (Sweden)

    Hardt Jochen

    2012-12-01

    Full Text Available Abstract Background Multiple imputation is becoming increasingly popular. Theoretical considerations as well as simulation studies have shown that the inclusion of auxiliary variables is generally of benefit. Methods A simulation study of a linear regression with a response Y and two predictors X1 and X2 was performed on data with n = 50, 100 and 200 using complete cases or multiple imputation with 0, 10, 20, 40 and 80 auxiliary variables. Mechanisms of missingness were either 100% MCAR or 50% MAR + 50% MCAR. Auxiliary variables had low (r=.10 vs. moderate correlations (r=.50 with X’s and Y. Results The inclusion of auxiliary variables can improve a multiple imputation model. However, inclusion of too many variables leads to downward bias of regression coefficients and decreases precision. When the correlations are low, inclusion of auxiliary variables is not useful. Conclusion More research on auxiliary variables in multiple imputation should be performed. A preliminary rule of thumb could be that the ratio of variables to cases with complete data should not go below 1 : 3.

  14. Estimating water equivalent snow depth from related meteorological variables

    International Nuclear Information System (INIS)

    Steyaert, L.T.; LeDuc, S.K.; Strommen, N.D.; Nicodemus, M.L.; Guttman, N.B.

    1980-05-01

    Engineering design must take into consideration natural loads and stresses caused by meteorological elements, such as, wind, snow, precipitation and temperature. The purpose of this study was to determine a relationship of water equivalent snow depth measurements to meteorological variables. Several predictor models were evaluated for use in estimating water equivalent values. These models include linear regression, principal component regression, and non-linear regression models. Linear, non-linear and Scandanavian models are used to generate annual water equivalent estimates for approximately 1100 cooperative data stations where predictor variables are available, but which have no water equivalent measurements. These estimates are used to develop probability estimates of snow load for each station. Map analyses for 3 probability levels are presented

  15. Emittance measurements by variable quadrupole method

    International Nuclear Information System (INIS)

    Toprek, D.

    2005-01-01

    The beam emittance is a measure of both the beam size and beam divergence, we cannot directly measure its value. If the beam size is measured at different locations or under different focusing conditions such that different parts of the phase space ellipse will be probed by the beam size monitor, the beam emittance can be determined. An emittance measurement can be performed by different methods. Here we will consider the varying quadrupole setting method.

  16. Measurement and modeling of diel variability of polybrominated diphenyl ethers and chlordanes in air.

    Science.gov (United States)

    Moeckel, Claudia; Macleod, Matthew; Hungerbühler, Konrad; Jones, Kevin C

    2008-05-01

    Short-term variability of concentrations of polybrominated diphenyl ethers (PBDEs) and chlordanes in air at a semirural site in England over a 5 day period is reported. Four-hour air samples were collected during a period dominated by a high pressure system that produced stable diel (24-h) patterns of meteorological conditions such as temperature and atmospheric boundary layer height. PBDE and chlordane concentrations showed clear diel variability with concentrations in the afternoon and evening being 1.9 - 2.7 times higher than in the early morning. The measurements are interpreted using a multimedia mass balance model parametrized with forcing functions representing local temperature, atmospheric boundary layer height, wind speed and hydroxyl radical concentrations. Model results indicate that reversible, temperature-controlled air-surface exchange is the primary driver of the diel concentration pattern observed for chlordanes and PBDE 28. For higher brominated PBDE congeners (47, 99 and 100), the effect of variable atmospheric mixing height in combination with irreversible deposition on aerosol particles is dominant and explains the diel patterns almost entirely. Higher concentrations of chlordanes and PBDEs in air observed at the end of the study period could be related to likely source areas using back trajectory analysis. This is the first study to clearly document diel variability in concentrations of PBDEs in air over a period of several days. Our model analysis indicates that high daytime and low nighttime concentrations of semivolatile organic chemicals can arise from different underlying driving processes, and are not necessarily evidence of reversible air-surface exchange on a 24-h time scale.

  17. On the intrinsic timescales of temporal variability in measurements of the surface solar radiation

    Science.gov (United States)

    Bengulescu, Marc; Blanc, Philippe; Wald, Lucien

    2018-01-01

    This study is concerned with the intrinsic temporal scales of the variability in the surface solar irradiance (SSI). The data consist of decennial time series of daily means of the SSI obtained from high-quality measurements of the broadband solar radiation impinging on a horizontal plane at ground level, issued from different Baseline Surface Radiation Network (BSRN) ground stations around the world. First, embedded oscillations sorted in terms of increasing timescales of the data are extracted by empirical mode decomposition (EMD). Next, Hilbert spectral analysis is applied to obtain an amplitude-modulation-frequency-modulation (AM-FM) representation of the data. The time-varying nature of the characteristic timescales of variability, along with the variations in the signal intensity, are thus revealed. A novel, adaptive null hypothesis based on the general statistical characteristics of noise is employed in order to discriminate between the different features of the data, those that have a deterministic origin and those being realizations of various stochastic processes. The data have a significant spectral peak corresponding to the yearly variability cycle and feature quasi-stochastic high-frequency variability components, irrespective of the geographical location or of the local climate. Moreover, the amplitude of this latter feature is shown to be modulated by variations in the yearly cycle, which is indicative of nonlinear multiplicative cross-scale couplings. The study has possible implications on the modeling and the forecast of the surface solar radiation, by clearly discriminating the deterministic from the quasi-stochastic character of the data, at different local timescales.

  18. Linear variable differential transformer and its uses for in-core fuel rod behavior measurements

    International Nuclear Information System (INIS)

    Wolf, J.R.

    1979-01-01

    The linear variable differential transformer (LVDT) is an electromechanical transducer which produces an ac voltage proportional to the displacement of a movable ferromagnetic core. When the core is connected to the cladding of a nuclear fuel rod, it is capable of producing extremely accurate measurements of fuel rod elongation caused by thermal expansion. The LVDT is used in the Thermal Fuels Behavior Program at the U.S. Idaho National Engineering Laboratory (INEL) for measurements of nuclear fuel rod elongation and as an indication of critical heat flux and the occurrence of departure from nucleate boiling. These types of measurements provide important information about the behavior of nuclear fuel rods under normal and abnormal operating conditions. The objective of the paper is to provide a complete account of recent advances made in LVDT design and experimental data from in-core nuclear reactor tests which use the LVDT

  19. Prenatal Triclosan Exposure and Anthropometric Measures Including Anogenital Distance in Danish Infants

    DEFF Research Database (Denmark)

    Lassen, Tina Harmer; Frederiksen, Hanne; Kyhl, Henriette Boye

    2016-01-01

    , Swan SH, Main KM, Andersson AM, Lind DV, Husby S, Wohlfahrt-Veje C, Skakkebæk NE, Jensen TK. 2016. Prenatal triclosan exposure and anthropometric measures including anogenital distance in Danish infants. Environ Health Perspect 124:1261-1268; http://dx.doi.org/10.1289/ehp.1409637.......BACKGROUND: Triclosan (TCS) is widely used as an antibacterial agent in consumer products such as hand soap and toothpaste, and human exposure is widespread. TCS is suspected of having endocrine-disrupting properties, but few human studies have examined the developmental effects of prenatal TCS...

  20. Continuous measurement of heart rate variability following carbon ...

    African Journals Online (AJOL)

    Background: Previous studies of autonomic nervous system activity through analysis of heart rate variability (HRV) have demonstrated increased sympathetic activity during positive-pressure pneumoperitoneum. We employed an online, continuous method for rapid HRV analysis (MemCalc™, Tarawa, Suwa Trust, Tokyo, ...

  1. The vulnerability of Australian rural communities to climate variability and change: Part I—Conceptualising and measuring vulnerability

    NARCIS (Netherlands)

    Nelson, R.; Kokic, P.; Crimp, S.; Meinke, H.B.; Howden, S.M.

    2010-01-01

    Vulnerability is a term frequently used to describe the potential threat to rural communities posed by climate variability and change. Despite growing use of the term, analytical measures of vulnerability that are useful for prioritising and evaluating policy responses are yet to evolve. Demand for

  2. Measurement of circulating cell-derived microparticles by flow cytometry: sources of variability within the assay.

    Science.gov (United States)

    Ayers, Lisa; Kohler, Malcolm; Harrison, Paul; Sargent, Ian; Dragovic, Rebecca; Schaap, Marianne; Nieuwland, Rienk; Brooks, Susan A; Ferry, Berne

    2011-04-01

    Circulating cell-derived microparticles (MPs) have been implicated in several disease processes and elevated levels are found in many pathological conditions. The detection and accurate measurement of MPs, although attracting widespread interest, is hampered by a lack of standardisation. The aim of this study was to establish a reliable flow cytometric assay to measure distinct subtypes of MPs in disease and to identify any significant causes of variability in MP quantification. Circulating MPs within plasma were identified by their phenotype (platelet, endothelial, leukocyte and annexin-V positivity (AnnV+). The influence of key variables (i.e. time between venepuncture and centrifugation, washing steps, the number of centrifugation steps, freezing/long-term storage and temperature of thawing) on MP measurement were investigated. Increasing time between venepuncture and centrifugation leads to increased MP levels. Washing samples results in decreased AnnV+MPs (P=0.002) and platelet-derived MPs (PMPs) (P=0.002). Double centrifugation of MPs prior to freezing decreases numbers of AnnV+MPs (P=0.0004) and PMPs (P=0.0004). A single freeze thaw cycle of samples led to an increase in AnnV+MPs (P=0.0020) and PMPs (P=0.0039). Long-term storage of MP samples at -80° resulted in decreased MP levels. This study found that minor protocol changes significantly affected MP levels. This is one of the first studies attempting to standardise a method for obtaining and measuring circulating MPs. Standardisation will be essential for successful development of MP technologies, allowing direct comparison of results between studies and leading to a greater understanding of MPs in disease. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.

  3. Hypersonic Boundary Layer Measurements with Variable Blowing Rates Using Molecular Tagging Velocimetry

    Science.gov (United States)

    Bathel, Brett F.; Danehy, Paul M.; Johansen, Craig T.; Jones, Stephen B.; Goyne, Christopher P.

    2012-01-01

    Measurements of mean and instantaneous streamwise velocity profiles in a hypersonic boundary layer with variable rates of mass injection (blowing) of nitrogen dioxide (NO2) were obtained over a 10-degree half-angle wedge model. The NO2 was seeded into the flow from a slot located 29.4 mm downstream of the sharp leading edge. The top surface of the wedge was oriented at a 20 degree angle in the Mach 10 flow, yielding an edge Mach number of approximately 4.2. The streamwise velocity profiles and streamwise fluctuating velocity component profiles were obtained using a three-laser NO2->NO photolysis molecular tagging velocimetry method. Observed trends in the mean streamwise velocity profiles and profiles of the fluctuating component of streamwise velocity as functions of the blowing rate are described. An effort is made to distinguish between the effect of blowing rate and wall temperature on the measured profiles. An analysis of the mean velocity profiles for a constant blowing rate is presented to determine the uncertainty in the measurement for different probe laser delay settings. Measurements of streamwise velocity were made to within approximately 120 gm of the model surface. The streamwise spatial resolution in this experiment ranged from 0.6 mm to 2.6 mm. An improvement in the spatial precision of the measurement technique has been made, with spatial uncertainties reduced by about a factor of 2 compared to previous measurements. For the quiescent flow calibration measurements presented, uncertainties as low as 2 m/s are obtained at 95% confidence for long delay times (25 gs). For the velocity measurements obtained with the wind tunnel operating, average single-shot uncertainties of less than 44 m/s are obtained at 95% confidence with a probe laser delay setting of 1 gs. The measurements were performed in the 31-inch Mach 10 Air Tunnel at the NASA Langley Research Center.

  4. Inlet-engine matching for SCAR including application of a bicone variable geometry inlet

    Science.gov (United States)

    Wasserbauer, J. F.; Gerstenmaier, W. H.

    1978-01-01

    Airflow characteristics of variable cycle engines (VCE) designed for Mach 2.32 can have transonic airflow requirements as high as 1.6 times the cruise airflow. This is a formidable requirement for conventional, high performance, axisymmetric, translating centerbody mixed compression inlets. An alternate inlet is defined, where the second cone of a two cone center body collapses to the initial cone angle to provide a large off-design airflow capability, and incorporates modest centerbody translation to minimize spillage drag. Estimates of transonic spillage drag are competitive with those of conventional translating centerbody inlets. The inlet's cruise performance exhibits very low bleed requirements with good recovery and high angle of attack capability.

  5. Continuous measurement of heart rate variability following carbon ...

    African Journals Online (AJOL)

    2010-07-16

    Jul 16, 2010 ... Power spectral analysis of the electrocardiographic R-R interval [heart rate variability: (HRV)] is a well known, non- invasive method for assessing autonomic nervous activity.1. Studies using HRV analysis during positive-pressure pneumoperitoneum (PPP) have demonstrated increased sympathetic ...

  6. Spectral interferometry including the effect of transparent thin films to measure distances and displacements

    International Nuclear Information System (INIS)

    Hlubina, P.

    2004-01-01

    A spectral-domain interferometric technique is applied for measuring mirror distances and displacements in a dispersive Michelson interferometer when the effect of transparent thin films coated onto the interferometer beam splitter and compensator is known. We employ a low-resolution spectrometer in two experiments with different amounts of dispersion in a Michelson interferometer that includes fused-silica optical sample. Knowing the thickness of the optical sample and the nonlinear phase function of the thin films, the positions of the interferometer mirror are determined precisely by a least-squares fitting of the theoretical spectral interferograms to the recorded ones. We compare the results of the processing that include and do not include the effect of transparent thin films (Author)

  7. Development of a scale to measure adherence to self-monitoring of blood glucose with latent variable measurement.

    Science.gov (United States)

    Wagner, J A; Schnoll, R A; Gipson, M T

    1998-07-01

    Adherence to self-monitoring of blood glucose (SMBG) is problematic for many people with diabetes. Self-reports of adherence have been found to be unreliable, and existing paper-and-pencil measures have limitations. This study developed a brief measure of SMBG adherence with good psychometric properties and a useful factor structure that can be used in research and in practice. A total of 216 adults with diabetes responded to 30 items rated on a 9-point Likert scale that asked about blood monitoring habits. In part I of the study, items were evaluated and retained based on their psychometric properties. The sample was divided into exploratory and confirmatory halves. Using the exploratory half, items with acceptable psychometric properties were subjected to a principal components analysis. In part II of the study, structural equation modeling was used to confirm the component solution with the entire sample. Structural modeling was also used to test the relationship between these components. It was hypothesized that the scale would produce four correlated factors. Principal components analysis suggested a two-component solution, and confirmatory factor analysis confirmed this solution. The first factor measures the degree to which patients rely on others to help them test and thus was named "social influence." The second component measures the degree to which patients use physical symptoms of blood glucose levels to help them test and thus was named "physical influence." Results of the structural model show that the components are correlated and make up the higher-order latent variable adherence. The resulting 15-item scale provides a short, reliable way to assess patient adherence to SMBG. Despite the existence of several aspects of adherence, this study indicates that the construct consists of only two components. This scale is an improvement on previous measures of adherence because of its good psychometric properties, its interpretable factor structure, and its

  8. Near-infrared Variability in the 2MASS Calibration Fields: A Search for Planetary Transit Candidates

    Science.gov (United States)

    Plavchan, Peter; Jura, M.; Kirkpatrick, J. Davy; Cutri, Roc M.; Gallagher, S. C.

    2008-01-01

    The Two Micron All Sky Survey (2MASS) photometric calibration observations cover approximately 6 square degrees on the sky in 35 'calibration fields,' each sampled in nominal photometric conditions between 562 and 3692 times during the 4 years of the 2MASS mission. We compile a catalog of variables from the calibration observations to search for M dwarfs transited by extrasolar planets. We present our methods for measuring periodic and nonperiodic flux variability. From 7554 sources with apparent K(sub s) magnitudes between 5.6 and 16.1, we identify 247 variables, including extragalactic variables and 23 periodic variables. We have discovered three M dwarf eclipsing systems, including two candidates for transiting extrasolar planets.

  9. Variability in Light-Duty Gasoline Vehicle Emission Factors from Trip-Based Real-World Measurements.

    Science.gov (United States)

    Liu, Bin; Frey, H Christopher

    2015-10-20

    Using data obtained with portable emissions measurements systems (PEMS) on multiple routes for 100 gasoline vehicles, including passenger cars (PCs), passenger trucks (PTs), and hybrid electric vehicles (HEVs), variability in tailpipe emission rates was evaluated. Tier 2 emission standards are shown to be effective in lowering NOx, CO, and HC emission rates. Although PTs are larger, heavier vehicles that consume more fuel and produce more CO2 emissions, they do not necessarily produce more emissions of regulated pollutants compared to PCs. HEVs have very low emission rates compared to tier 2 vehicles under real-world driving. Emission factors vary with cycle average speed and road type, reflecting the combined impact of traffic control and traffic congestion. Compared to the slowest average speed and most congested cycles, optimal emission rates could be 50% lower for CO2, as much as 70% lower for NOx, 40% lower for CO, and 50% lower for HC. There is very high correlation among vehicles when comparing driving cycles. This has implications for how many cycles are needed to conduct comparisons between vehicles, such as when comparing fuels or technologies. Concordance between empirical and predicted emission rates using the U.S. Environmental Protection Agency's MOVES model was also assessed.

  10. Comparing measured and modelled soil carbon: which site-specific variables are linked to high stability?

    Science.gov (United States)

    Robertson, Andy; Schipanski, Meagan; Ma, Liwang; Ahuja, Lajpat; McNamara, Niall; Smith, Pete; Davies, Christian

    2016-04-01

    Changes in soil carbon (C) stocks have been studied in depth over the last two decades, as net greenhouse gas (GHG) sinks are highlighted to be a partial solution to the causes of climate change. However, the stability of this soil C is often overlooked when measuring these changes. Ultimately a net sequestration in soils is far less beneficial if labile C is replacing more stable forms. To date there is no accepted framework for measuring soil C stability, and as a result there is considerable uncertainty associated with the simulated impacts of land management and land use change when using process-based systems models. However, a recent effort to equate measurable soil C fractions to model pools has generated data that help to assess the impacts of land management, and can ultimately help to reduce the uncertainty of model predictions. Our research compiles this existing fractionation data along with site metadata to create a simplistic statistical model able to quantify the relative importance of different site-specific conditions. Data was mined from 23 published studies and combined with original data to generate a dataset of 100+ land use change sites across Europe. For sites to be included they required soil C fractions isolated using the Zimmermann et al. (2007) method and specific site metadata (mean annual precipitation, MAP; mean annual temperature, MAT; soil pH; land use; altitude). Of the sites, 75% were used to develop a generalized linear mixed model (GLMM) to create coefficients where site parameters can be used to predict influence on the measured soil fraction C stocks. The remaining 25% of sites were used to evaluate uncertainty and validate this empirical model. Further, four of the aforementioned sites were used to simulate soil C dynamics using the RothC, DayCent and RZWQM2 models. A sensitivity analysis (4096 model runs for each variable applying Latin hypercube random sampling techniques) was then used to observe whether these models place

  11. Conceptualising computerized adaptive testing for measurement of latent variables associated with physical objects

    International Nuclear Information System (INIS)

    Camargo, F R; Henson, B

    2015-01-01

    The notion of that more or less of a physical feature affects in different degrees the users' impression with regard to an underlying attribute of a product has frequently been applied in affective engineering. However, those attributes exist only as a premise that cannot directly be measured and, therefore, inferences based on their assessment are error-prone. To establish and improve measurement of latent attributes it is presented in this paper the concept of a stochastic framework using the Rasch model for a wide range of independent variables referred to as an item bank. Based on an item bank, computerized adaptive testing (CAT) can be developed. A CAT system can converge into a sequence of items bracketing to convey information at a user's particular endorsement level. It is through item banking and CAT that the financial benefits of using the Rasch model in affective engineering can be realised

  12. Including investment risk in large-scale power market models

    DEFF Research Database (Denmark)

    Lemming, Jørgen Kjærgaard; Meibom, P.

    2003-01-01

    Long-term energy market models can be used to examine investments in production technologies, however, with market liberalisation it is crucial that such models include investment risks and investor behaviour. This paper analyses how the effect of investment risk on production technology selection...... can be included in large-scale partial equilibrium models of the power market. The analyses are divided into a part about risk measures appropriate for power market investors and a more technical part about the combination of a risk-adjustment model and a partial-equilibrium model. To illustrate...... the analyses quantitatively, a framework based on an iterative interaction between the equilibrium model and a separate risk-adjustment module was constructed. To illustrate the features of the proposed modelling approach we examined how uncertainty in demand and variable costs affects the optimal choice...

  13. Alcohol intake and colorectal cancer: a comparison of approaches for including repeated measures of alcohol consumption

    DEFF Research Database (Denmark)

    Thygesen, Lau Caspar; Wu, Kana; Grønbaek, Morten

    2008-01-01

    BACKGROUND: In numerous studies, alcohol intake has been found to be positively associated with colorectal cancer risk. However, the majority of studies included only one exposure measurement, which may bias the results if long-term intake is relevant.METHODS: We compared different approaches...... for including repeated measures of alcohol intake among 47,432 US men enrolled in the Health Professionals Follow-up Study. Questionnaires including questions on alcohol intake had been completed in 1986, 1990, 1994, and 1998. The outcome was incident colorectal cancer during follow-up from 1986 to 2002.RESULTS......: During follow-up, 868 members of the cohort experienced colorectal cancer. Baseline, updated, and cumulative average alcohol intakes were positively associated with colorectal cancer, with only minor differences among the approaches. These results support moderately increased risk for intake >30 g...

  14. The impact of obstructive sleep apnea variability measured in-lab versus in-home on sample size calculations

    Directory of Open Access Journals (Sweden)

    Levendowski Daniel

    2009-01-01

    Full Text Available Abstract Background When conducting a treatment intervention, it is assumed that variability associated with measurement of the disease can be controlled sufficiently to reasonably assess the outcome. In this study we investigate the variability of Apnea-Hypopnea Index obtained by polysomnography and by in-home portable recording in untreated mild to moderate obstructive sleep apnea (OSA patients at a four- to six-month interval. Methods Thirty-seven adult patients serving as placebo controls underwent a baseline polysomnography and in-home sleep study followed by a second set of studies under the same conditions. The polysomnography studies were acquired and scored at three independent American Academy of Sleep Medicine accredited sleep laboratories. The in-home studies were acquired by the patient and scored using validated auto-scoring algorithms. The initial in-home study was conducted on average two months prior to the first polysomnography, the follow-up polysomnography and in-home studies were conducted approximately five to six months after the initial polysomnography. Results When comparing the test-retest Apnea-hypopnea Index (AHI and apnea index (AI, the in-home results were more highly correlated (r = 0.65 and 0.68 than the comparable PSG results (r = 0.56 and 0.58. The in-home results provided approximately 50% less test-retest variability than the comparable polysomnography AHI and AI values. Both the overall polysomnography AHI and AI showed a substantial bias toward increased severity upon retest (8 and 6 events/hr respectively while the in-home bias was essentially zero. The in-home percentage of time supine showed a better correlation compared to polysomnography (r = 0.72 vs. 0.43. Patients biased toward more time supine during the initial polysomnography; no trends in time supine for in-home studies were noted. Conclusion Night-to-night variability in sleep-disordered breathing can be a confounding factor in assessing

  15. The IL--6 dependent effect of oral warfarin in heart valve replacement patients by measuring interacting clinical and demographic variables

    International Nuclear Information System (INIS)

    Shafiq, H.; Rashid, A.; Majeed, A.; Razah, S.; Asghar, I.

    2016-01-01

    Objective: To examine an inflammatory effect of warfarin and comparing with IL-6 levels along with different demographic and clinical variables. Study Design: Quasi experimental study. Place and Duration of Study: Center of Research in Experimental and Applied Medicine (CREAM), Army Medical College/National University of Sciences and Technology, Islamabad from Oct 2013 to Oct 2015. Material and Methods: The study design was Quasi Experimental study. Samples were collected by Non probability convenience sampling. Total 76 patients were included according to warfarin dose response in warfarin therapy patients, i.e. 32(42 percent) were taking 10mg/day of warfarin dose. Patient's demographic and clinical variables were noted i.e. age, gender, BMI, duration of therapy, INR history, hepatic, gastrointestinal and diabetic complications. Human IL-6 ELISA assay was performed. Results: The statistically significant difference was found between age groups (in years) and different levels of warfarin dose (p=0.046) along with IL-6 production. There is a negative correlation between warfarin dose and age group i.e. as age increases, the dose of warfarin decreases. Among the inter and intra-patient variability age and serum IL-6 levels were found to be statistically significant with warfarin dose response. BMI and warfarin dose were found to be weak positively correlated. Conclusion: A marked immunomodulatory response of warfarin was noted by measuring IL-6 levels. IL-6 levels retained a significant association with warfarin dose. (author)

  16. Uncertainty importance measure for models with correlated normal variables

    International Nuclear Information System (INIS)

    Hao, Wenrui; Lu, Zhenzhou; Wei, Pengfei

    2013-01-01

    In order to explore the contributions by correlated input variables to the variance of the model output, the contribution decomposition of the correlated input variables based on Mara's definition is investigated in detail. By taking the quadratic polynomial output without cross term as an illustration, the solution of the contribution decomposition is derived analytically using the statistical inference theory. After the correction of the analytical solution is validated by the numerical examples, they are employed to two engineering examples to show their wide application. The derived analytical solutions can directly be used to recognize the contributions by the correlated input variables in case of the quadratic or linear polynomial output without cross term, and the analytical inference method can be extended to the case of higher order polynomial output. Additionally, the origins of the interaction contribution of the correlated inputs are analyzed, and the comparisons of the existing contribution indices are completed, on which the engineer can select the suitable indices to know the necessary information. At last, the degeneration of the correlated inputs to the uncorrelated ones and some computational issues are discussed in concept

  17. Using Copulas in the Estimation of the Economic Project Value in the Mining Industry, Including Geological Variability

    Science.gov (United States)

    Krysa, Zbigniew; Pactwa, Katarzyna; Wozniak, Justyna; Dudek, Michal

    2017-12-01

    Geological variability is one of the main factors that has an influence on the viability of mining investment projects and on the technical risk of geology projects. In the current scenario, analyses of economic viability of new extraction fields have been performed for the KGHM Polska Miedź S.A. underground copper mine at Fore Sudetic Monocline with the assumption of constant averaged content of useful elements. Research presented in this article is aimed at verifying the value of production from copper and silver ore for the same economic background with the use of variable cash flows resulting from the local variability of useful elements. Furthermore, the ore economic model is investigated for a significant difference in model value estimated with the use of linear correlation between useful elements content and the height of mine face, and the approach in which model parameters correlation is based upon the copula best matched information capacity criterion. The use of copula allows the simulation to take into account the multi variable dependencies at the same time, thereby giving a better reflection of the dependency structure, which linear correlation does not take into account. Calculation results of the economic model used for deposit value estimation indicate that the correlation between copper and silver estimated with the use of copula generates higher variation of possible project value, as compared to modelling correlation based upon linear correlation. Average deposit value remains unchanged.

  18. Longterm and spatial variability of Aerosol optical properties measured by sky radiometer in Japan sites

    Science.gov (United States)

    Aoki, K.

    2016-12-01

    Aerosols and cloud play an important role in the climate change. We started the long-term monitoring of aerosol and cloud optical properties since 1990's by using sky radiometer (POM-01, 02; Prede Co. Ltd., Japan). We provide the information, in this presentation, on the aerosol optical properties with respect to their temporal and spatial variability in Japan site (ex. Sapporo, Toyama, Kasuga and etc). The global distributions of aerosols have been derived from earth observation satellite and have been simulated in numerical models, which assume optical parameters. However, these distributions are difficult to derive because of variability in time and space. Therefore, Aerosol optical properties were investigated using the measurements from ground-based and ship-borne sky radiometer. The sky radiometer is an automatic instrument that takes observations only in daytime under the clear sky conditions. Observation of diffuse solar intensity interval was made every ten or five minutes by once. The aerosol optical properties were computed using the SKYRAD.pack version 4.2. The obtained Aerosol optical properties (Aerosol optical thickness, Ångström exponent, Single scattering albedo, and etc.) and size distribution volume clearly showed spatial and temporal variability in Japan area. In this study, we present the temporal and spatial variability of Aerosol optical properties at several Japan sites, applied to validation of satellite and numerical models. This project is validation satellite of GCOM-C, JAXA. The GCOM-C satellite scheduled to be launched in early 2017.

  19. Linear versus non-linear measures of temporal variability in finger tapping and their relation to performance on open- versus closed-loop motor tasks: comparing standard deviations to Lyapunov exponents.

    Science.gov (United States)

    Christman, Stephen D; Weaver, Ryan

    2008-05-01

    The nature of temporal variability during speeded finger tapping was examined using linear (standard deviation) and non-linear (Lyapunov exponent) measures. Experiment 1 found that right hand tapping was characterised by lower amounts of both linear and non-linear measures of variability than left hand tapping, and that linear and non-linear measures of variability were often negatively correlated with one another. Experiment 2 found that increased non-linear variability was associated with relatively enhanced performance on a closed-loop motor task (mirror tracing) and relatively impaired performance on an open-loop motor task (pointing in a dark room), especially for left hand performance. The potential uses and significance of measures of non-linear variability are discussed.

  20. Tracer responses and control of vessels with variable flow and volume

    International Nuclear Information System (INIS)

    Niemi, A.J.

    1990-01-01

    Continuous flow vessels which are subject to variation of flow and volume are characterized by time-variable parameters. It is shown that their residence time distributions and weighting functions obtained by tracer testing are made invariant with regard to the integrated flow variables which are introduced. Under variable flow but constant volume, one such integrated variable is sufficient. Under variable volume, two different variables are suggested for the residence time distribution and weighting function, while the appropriate variable of the perfect mixer differs distinctly from that of vessels with a distinct velocity profile. It is shown through a number of example cases, that an agreement with their mathematical models is reached. The approach is extended to include also arbitrary, non-analytic response functions obtained by tracer measurements. Applications of the derived models and their incorporation in automatic control algorithms is discussed. (orig.) [de

  1. Chapter 18: Variable Frequency Drive Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Romberger, Jeff [SBW Consulting, Inc., Bellevue, WA (United States)

    2017-06-21

    An adjustable-speed drive (ASD) includes all devices that vary the speed of a rotating load, including those that vary the motor speed and linkage devices that allow constant motor speed while varying the load speed. The Variable Frequency Drive Evaluation Protocol presented here addresses evaluation issues for variable-frequency drives (VFDs) installed on commercial and industrial motor-driven centrifugal fans and pumps for which torque varies with speed. Constant torque load applications, such as those for positive displacement pumps, are not covered by this protocol.

  2. The temporal variability of species densities

    International Nuclear Information System (INIS)

    Redfearn, A.; Pimm, S.L.

    1993-01-01

    Ecologists use the term 'stability' to mean to number of different things (Pimm 1984a). One use is to equate stability with low variability in population density over time (henceforth, temporal variability). Temporal variability varies greatly from species to species, so what effects it? There are at least three sets of factors: the variability of extrinsic abiotic factors, food web structure, and the intrinsic features of the species themselves. We can measure temporal variability using at least three statistics: the coefficient of variation of density (CV); the standard deviation of the logarithms of density (SDL); and the variance in the differences between logarithms of density for pairs of consecutive years (called annual variability, hence AV, b y Wolda 1978). There are advantages and disadvantages to each measure (Williamson 1984), though in our experience, the measures are strongly correlated across sets of taxonomically related species. The increasing availability of long-term data sets allows one to calculate these statistics for many species and so to begin to understand the various causes of species differences in temporal variability

  3. Variable frequency microwave heating apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Bible, D.W.; Lauf, R.J.; Johnson, A.C.; Thigpen, L.T.

    1999-10-05

    A variable frequency microwave heating apparatus (10) designed to allow modulation of the frequency of the microwaves introduced into a multi-mode microwave cavity (34) for testing or other selected applications. The variable frequency microwave heating apparatus (10) includes a microwave signal generator (12) and a high-power microwave amplifier (20) or a high-power microwave oscillator (14). A power supply (22) is provided for operation of the high-power microwave oscillator (14) or microwave amplifier (20). A directional coupler (24) is provided for detecting the direction and amplitude of signals incident upon and reflected from the microwave cavity (34). A first power meter (30) is provided for measuring the power delivered to the microwave furnace (32). A second power meter (26) detects the magnitude of reflected power. Reflected power is dissipated in the reflected power load (28).

  4. Identifying Pertinent Variables for Nonresponse Follow-Up Surveys. Lessons Learned from 4 Cases in Switzerland

    Directory of Open Access Journals (Sweden)

    Caroline Vandenplas

    2015-12-01

    Full Text Available All social surveys suffer from different types of errors, of which one of the most studied is non-response bias. Non-response bias is a systematic error that occurs because individuals differ in their accessibility and propensity to participate in a survey according to their own characteristics as well as those from the survey itself. The extent of the problem heavily depends on the correlation between response mechanisms and key survey variables. However, non-response bias is difficult to measure or to correct for due to the lack of relevant data about the whole target population or sample. In this paper, non-response follow-up surveys are considered as a possible source of information about non-respondents. Non-response follow-ups, however, suffer from two methodological issues: they themselves operate through a response mechanism that can cause potential non-response bias, and they pose a problem of comparability of measure, mostly because the survey design differs between main survey and non-response follow-up. In order to detect possible bias, the survey variables included in non-response surveys have to be related to the mechanism of participation, but not be sensitive to measurement effects due to the different designs. Based on accumulated experience of four similar non-response follow-ups, we studied the survey variables that fulfill these conditions. We differentiated socio-demographic variables that are measurement-invariant but have a lower correlation with non-response and variables that measure attitudes, such as trust, social participation, or integration in the public sphere, which are more sensitive to measurement effects but potentially more appropriate to account for the non-response mechanism. Our results show that education level, work status, and living alone, as well as political interest, satisfaction with democracy, and trust in institutions are pertinent variables to include in non-response follow-ups of general social

  5. The Impact of Resonance Frequency Breathing on Measures of Heart Rate Variability, Blood Pressure, and Mood

    Directory of Open Access Journals (Sweden)

    Patrick R. Steffen

    2017-08-01

    Full Text Available Heart rate variability biofeedback (HRVB significantly improves heart rate variability (HRV. Breathing at resonance frequency (RF, approximately 6 breaths/min constitutes a key part of HRVB training and is hypothesized to be a pathway through which biofeedback improves HRV. No studies to date, however, have experimentally examined whether RF breathing impacts measures of HRV. The present study addressed this question by comparing three groups: the RF group breathed at their determined RF for 15 min; the RF + 1 group breathed at 1 breath/min higher than their determined RF for 15 min; and the third group sat quietly for 15 min. After this 15-min period, all groups participated in the Paced Auditory Serial Addition Task (PASAT for 8 min, and then sat quietly during a 10-min recovery period. HRV, blood pressure, and mood were measured throughout the experiment. Groups were not significantly different on any of the measures at baseline. After the breathing exercise, the RF group reported higher positive mood than the other two groups and a significantly higher LF/HF HRV ratio relative to the control group, a key goal in HRVB training (p < 0.05. Additionally, the RF group showed lower systolic blood pressure during the PASAT and during the recovery period relative to the control group, with the RF + 1 group not being significantly different from either group (p < 0.05. Overall, RF breathing appears to play an important role in the positive effect HRVB has on measures of HRV.

  6. The nebular variables

    CERN Document Server

    Glasby, John S

    1974-01-01

    The Nebular Variables focuses on the nebular variables and their characteristics. Discussions are organized by type of nebular variable, namely, RW Aurigae stars, T Orionis stars, T Tauri stars, and peculiar nebular objects. Topics range from light variations of the stars to their spectroscopic and physical characteristics, spatial distribution, interaction with nebulosity, and evolutionary features. This volume is divided into four sections and consists of 25 chapters, the first of which provides general information on nebular variables, including their stellar associations and their classifi

  7. Variability of skin autofluorescence measurement over 6 and 12 weeks and the influence of benfotiamine treatment.

    Science.gov (United States)

    Stirban, Alin; Pop, Alexandra; Fischer, Annelie; Heckermann, Sascha; Tschoepe, Diethelm

    2013-09-01

    Measurements of skin autofluorescence (SAF) allow for a simple and noninvasive quantification of tissue advanced glycation end-products (AGEs), a marker linked to the risk of diabetes complications. The aim of this study was to test the repeatability of SAF over 6 and 12 weeks and to test whether benfotiamine, a thiamine prodrug suggested to reduce AGEs formation under hyperglycemic conditions, is able to attenuate SAF when administered over 6 weeks. In a double-blind, placebo-controlled, randomized, crossover study, 22 patients with type 2 diabetes mellitus (T2DM) received 900 mg/day benfotiamine or placebo for 6 weeks (washout period of 6 weeks between). At the beginning and at the end of each treatment period, SAF was assessed in the fasting state, as well as 2, 4, and 6 h following a mixed test meal. The respective intra-individual and inter-individual variability of fasting SAF was 6.9% and 24.5% within 6 weeks and 10.9% and 23.1% within 12 weeks. The respective variability calculated for triplicate comparisons was 9.9% and 27.7%. A short-term therapy with benfotiamine did not influence SAF significantly, nor did we find a significant postprandial SAF increase. In patients with T2DM, repeated, timely spaced SAF measurements have an intra-subject variability of below 11%. Using these data, sample sizes were calculated for interventional studies aiming at reducing SAF. Benfotiamine treatment for 6 weeks did not significantly influence SAF; for this, a longer-term therapy is probably needed.

  8. Inner-shell/subshell photoionization cross section measurements using a gamma excited variable energy X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Sood, B S; Allawadhi, K L; Arora, S K [Punjabi Univ., Patiala (India). Nuclear Science Labs.

    1982-02-15

    The method developed for the determination of K/L shell photoionization cross sections in various elements, 39 <= Z <= 92, in the characteristic X-ray energy region using a gamma excited variable energy X-ray source has been used for the measurement of Lsub(III) subshell photoionization cross section in Pb, Th and U. The measurements are made at the K X-ray energies of Rb, Nb and Mo, since these are able to excite selectively the Lsub(III) subshells of Pb, Th and U, respectively. The results, when compared with theoretical calculations of Scofield, are found to agree within the uncertainties of determination.

  9. Ventricular short-axis measurements in patients with pulmonary embolism: Effect of ECG-gating on variability, accuracy, and risk prediction

    International Nuclear Information System (INIS)

    Scheffel, Hans; Stolzmann, Paul; Leschka, Sebastian; Desbiolles, Lotus; Seifert, Burkhardt; Marincek, Borut; Alkadhi, Hatem

    2012-01-01

    Objective: To assess prospectively the intra- and interobserver variability, accuracy, and prognostic value of right and left ventricular short-axis diameter (RVd and LVd) measurements for risk stratification in patients with pulmonary embolism (PE) using ECG-gated compared to non-gated CT. Materials and methods: Sixty consecutive patients (33 women; mean age 58.7 ± 10.3 years) with suspicion of PE underwent both non-gated and ECG-gated chest CT. RVd and LVd on four-chamber views and intra- and interobserver agreements were calculated for both protocols. RVd/LVd ratios were calculated and were related to 30-days adverse clinical events using receiver operating characteristics with area-under-the-curve (AUC) analyses. Results: Both inter- and intraobserver variability showed narrower limits of agreement for all measurements with ECG-gated as compared to non-gated CT. Diameter measurements were significantly lower using non-ECG-gated CT as compared to ECG-gated CT for RVd and LVd (both p < .05). The AUC for the RVd/LVd ratio from ECG-gated CT was significantly larger than that from non-gated CT (0.956, 95% CI: 0.768–0.999 versus 0.675, 95% CI: 0.439–0.860; p = .048). Conclusion: RVd and LVd measurements from ECG-gated chest CT show less intra- and interobserver variability and more accurately reflect ventricular function. In our patient cohort ECG-gated chest CT allows better prediction of short-term outcome of patients with acute PE that needs to be validated in a larger outcome study

  10. Validity of a questionnaire measuring motives for choosing foods including sustainable concerns.

    Science.gov (United States)

    Sautron, Valérie; Péneau, Sandrine; Camilleri, Géraldine M; Muller, Laurent; Ruffieux, Bernard; Hercberg, Serge; Méjean, Caroline

    2015-04-01

    Since the 1990s, sustainability of diet has become an increasingly important concern for consumers. However, there is no validated multidimensional measurement of motivation in the choice of foods including a concern for sustainability currently available. In the present study, we developed a questionnaire that measures food choice motives during purchasing, and we tested its psychometric properties. The questionnaire included 104 items divided into four predefined dimensions (environmental, health and well-being, economic and miscellaneous). It was administered to 1000 randomly selected subjects participating in the Nutrinet-Santé cohort study. Among 637 responders, one-third found the questionnaire complex or too long, while one-quarter found it difficult to fill in. Its underlying structure was determined by exploratory factor analysis and then internally validated by confirmatory factor analysis. Reliability was also assessed by internal consistency of selected dimensions and test-retest repeatability. After selecting the most relevant items, first-order analysis highlighted nine main dimensions: labeled ethics and environment, local and traditional production, taste, price, environmental limitations, health, convenience, innovation and absence of contaminants. The model demonstrated excellent internal validity (adjusted goodness of fit index = 0.97; standardized root mean square residuals = 0.07) and satisfactory reliability (internal consistency = 0.96, test-retest repeatability coefficient ranged between 0.31 and 0.68 over a mean 4-week period). This study enabled precise identification of the various dimensions in food choice motives and proposed an original, internally valid tool applicable to large populations for assessing consumer food motivation during purchasing, particularly in terms of sustainability. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Serodiagnosis of Borrelia miyamotoi disease by measuring antibodies against GlpQ and variable major proteins

    DEFF Research Database (Denmark)

    Koetsveld, J.; Kolyasnikova, N. M.; Wagemakers, A.

    2018-01-01

    previously shown the differential expression of antigenic variable major proteins (Vmps) in B. miyamotoi, our aim was to study antibody responses against GlpQ and Vmps in PCR-proven BMD patients and controls. Methods: We assessed seroreactivity against GlpQ and four Vmps in a well-described, longitudinal......, and IgG between 21 and 50 days, after disease onset. Various combinations of GlpQ and Vmps increased sensitivity and/or specificity compared to single antigens. Notably, the GlpQ or variable large protein (Vlp)-15/16 combination yielded a sensitivity of 94.7% (95% CI: 75.4–99.7) 11–20 days after disease......Objectives: Borrelia miyamotoi disease (BMD) is an emerging tick-borne disease in the Northern hemisphere. Serodiagnosis by measuring antibodies against glycerophosphodiester-phosphodiesterase (GlpQ) has been performed experimentally but has not been extensively clinically validated. Because we had...

  12. Measurement of high-departure aspheres using subaperture stitching with the Variable Optical Null (VON)

    Science.gov (United States)

    Kulawiec, Andrew; Murphy, Paul; DeMarco, Michael

    2010-10-01

    Aspheric surfaces are proven to provide significant benefits to a wide variety of optical systems, but the ability to produce high-precision aspheric surfaces has historically been limited by the ability (or lack thereof) to measure them. Traditionally, aspheric measurements have required dedicated null optics, but the cost, lead time, and calibration difficulty of using null optics has made the use of aspheres more challenging and less attractive. In the past three years, QED has developed the Subaperture Stitching Interferometer for Aspheres (SSI-A®) to help address this limitation, providing flexible aspheric measurement capability of up to 200 waves of aspheric departure from best-fit sphere. Some aspheres, however, have thousands of waves of departure. We have recently developed Variable Optical Null (VON) technology that can null much of the aspheric departure in a subaperture. The VON is automatically configurable and is adjusted to nearly null each specific subaperture of an asphere. This ability to nearly null a local subaperture of an asphere provides a significant boost in aspheric measurement capability, enabling aspheres with up to 1000 waves of departure to be measured, without the use of dedicated null optics. We outline the basic principles of subaperture stitching and VON technology, demonstrate the extended capability provided by the VON, and present measurement results from the new Aspheric Stitching Interferometer (ASI®).

  13. TU-A-12A-06: Intra-Observer Variability in Delineation of Target Volumes in Breast Radiotherapy and Its Effect On Accuracy of Deformation Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Juneja, P; Harris, E [The Institute of Cancer Research, London (United Kingdom); Royal Marsden NHS Foundation Trust, Sutton (United Kingdom); Bonora, M [University of Milan, Milan (Italy); Evans, P [University of Surrey, Guildford (United Kingdom)

    2014-06-15

    Purpose: In breast radiotherapy, the target volume may change during treatment and need adaptation of the treatment plan. This is possible for both tumour bed (TB) and whole breast (WB) target volumes. Delineation of the target (to detect changes) is also subject to uncertainty due to intra- and inter-observer variability. This work measured the uncertainty, due to intraobserver variability, in the quantification of tissue deformation. Methods: Datasets consisting of paired prone and supine CT scans of three patients were used. Significant deformation in target volumes is expected between prone and supine patient positions. The selected cases had 1) no seroma, 2) some seroma, and 3) large seroma. The TB and WB were outlined on each dataset three times by one clinician. Delineation variability was defined as the standard deviations of the distances between observer outlines. For each target volume and each case, tissue deformation between prone and supine delineations was quantified using the Dice similarity coefficient (DSC) and the average surface distance (ASD). The uncertainty in the tissue deformation (due to delineation variability) was quantified by measuring the ranges of DSC and ASD using all combinations of pairs of outlines (9 pairs). Results: For the TB, the range of delineation variability was 0.44-1.16 mm. The deformation, DSC and ASD, (and uncertainty in measurement) of the TB between prone and supine position of the cases were: 1) 0.21 (0.17-0.28) and 12.4 mm (11.8-13 mm); 2) 0.54 (0.51-0.57) and 3.3 mm (3.1-3.5 mm); 3) 0.62 (0.61-0.64) and 4.9 mm (4.6-5.2 mm). WB deformation measurements were subject to less uncertainty due to delineation variability than TB deformation measurements. Conclusion: For the first time, the uncertainty, due to observer variability, in the measurement of the deformation of breast target volumes was investigated. Deformations in these ranges would be difficult to detect. This work was supported in part by Cancer Research

  14. MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning

    International Nuclear Information System (INIS)

    Blackall, J M; Ahmad, S; Miquel, M E; McClelland, J R; Landau, D B; Hawkes, D J

    2006-01-01

    Respiratory organ motion has a significant impact on the planning and delivery of radiotherapy (RT) treatment for lung cancer. Currently widespread techniques, such as 4D-computed tomography (4DCT), cannot be used to measure variability of this motion from one cycle to the next. In this paper, we describe the use of fast magnetic resonance imaging (MRI) techniques to investigate the intra- and inter-cycle reproducibility of respiratory motion and also to estimate the level of errors that may be introduced into treatment delivery by using various breath-hold imaging strategies during lung RT planning. A reference model of respiratory motion is formed to enable comparison of different breathing cycles at any arbitrary position in the respiratory cycle. This is constructed by using free-breathing images from the inhale phase of a single breathing cycle, then co-registering the images, and thereby tracking landmarks. This reference model is then compared to alternative models constructed from images acquired during the exhale phase of the same cycle and the inhale phase of a subsequent cycle, to assess intra- and inter-cycle variability ('hysteresis' and 'reproducibility') of organ motion. The reference model is also compared to a series of models formed from breath-hold data at exhale and inhale. Evaluation of these models is carried out on data from ten healthy volunteers and five lung cancer patients. Free-breathing models show good levels of intra- and inter-cycle reproducibility across the tidal breathing range. Mean intra-cycle errors in the position of organ surface landmarks of 1.5(1.4)-3.5(3.3) mm for volunteers and 2.8(1.8)-5.2(5.2) mm for patients. Equivalent measures of inter-cycle variability across this range are 1.7(1.0)-3.9(3.3) mm for volunteers and 2.8(1.8)-3.3(2.2) mm for patients. As expected, models based on breath-hold sequences do not represent normal tidal motion as well as those based on free-breathing data, with mean errors of 4

  15. Wind variability and sheltering effects on measurements and modeling of air-water exchange for a small lake

    Science.gov (United States)

    Markfort, Corey D.; Resseger, Emily; Porté-Agel, Fernando; Stefan, Heinz

    2014-05-01

    Lakes with a surface area of less than 10 km2 account for over 50% of the global cumulative lake surface water area, and make up more than 99% of the total number of global lakes, ponds, and wetlands. Within the boreal regions as well as some temperate and tropical areas, a significant proportion of land cover is characterized by lakes or wetlands, which can have a dramatic effect on land-atmosphere fluxes as well as the local and regional energy budget. Many of these small water bodies are surrounded by complex terrain and forest, which cause the wind blowing over a small lake or wetland to be highly variable. Wind mixing of the lake surface layer affects thermal stratification, surface temperature and air-water gas transfer, e.g. O2, CO2, and CH4. As the wind blows from the land to the lake, wake turbulence behind trees and other shoreline obstacles leads to a recirculation zone and enhanced turbulence. This wake flow results in the delay of the development of wind shear stress on the lake surface, and the fetch required for surface shear stress to fully develop may be ~O(1 km). Interpretation of wind measurements made on the lake is hampered by the unknown effect of wake turbulence. We present field measurements designed to quantify wind variability over a sheltered lake. The wind data and water column temperature profiles are used to evaluate a new method to quantify wind sheltering of lakes that takes into account lake size, shape and the surrounding landscape features. The model is validated against field data for 36 Minnesota lakes. Effects of non-uniform sheltering and lake shape are also demonstrated. The effects of wind sheltering must be included in lake models to determine the effect of wind-derived energy inputs on lake stratification, surface gas transfer, lake water quality, and fish habitat. These effects are also important for correctly modeling momentum, heat, moisture and trace gas flux to the atmosphere.

  16. Music and metronome cues produce different effects on gait spatiotemporal measures but not gait variability in healthy older adults.

    Science.gov (United States)

    Wittwer, Joanne E; Webster, Kate E; Hill, Keith

    2013-02-01

    Rhythmic auditory cues including music and metronome beats have been used, sometimes interchangeably, to improve disordered gait arising from a range of clinical conditions. There has been limited investigation into whether there are optimal cue types. Different cue types have produced inconsistent effects across groups which differed in both age and clinical condition. The possible effect of normal ageing on response to different cue types has not been reported for gait. The aim of this study was to determine the effects of both rhythmic music and metronome cues on gait spatiotemporal measures (including variability) in healthy older people. Twelve women and seven men (>65 years) walked on an instrumented walkway at comfortable pace and then in time to each of rhythmic music and metronome cues at comfortable pace stepping frequency. Music but not metronome cues produced a significant increase in group mean gait velocity of 4.6 cm/s, due mostly to a significant increase in group mean stride length of 3.1cm. Both cue types produced a significant but small increase in cadence of 1 step/min. Mean spatio-temporal variability was low at baseline and did not increase with either cue type suggesting cues did not disrupt gait timing. Study findings suggest music and metronome cues may not be used interchangeably and cue type as well as frequency should be considered when evaluating effects of rhythmic auditory cueing on gait. Further work is required to determine whether optimal cue types and frequencies to improve walking in different clinical groups can be identified. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Variables Associated with the Use of Coercive Measures on Psychiatric Patients in Spanish Penitentiary Centers

    Directory of Open Access Journals (Sweden)

    E. Girela

    2014-01-01

    Full Text Available We have studied the use of coercive medical measures (forced medication, isolation, and mechanical restraint in mentally ill inmates within two secure psychiatric hospitals (SPH and three regular prisons (RP in Spain. Variables related to adopted coercive measures were analyzed, such as type of measure, causes of indication, opinion of patient inmate, opinion of medical staff, and more frequent morbidity. A total of 209 patients (108 from SPH and 101 from RP were studied. Isolation (41.35% was the most frequent coercive measure, followed by mechanical restraint (33.17% and forced medication (25.48%. The type of center has some influence; specifically in RP there is less risk of isolation and restraint than in SPH. Not having had any previous imprisonment reduces isolation and restraint risk while increases the risk of forced medication, as well as previous admissions to psychiatric inpatient units does. Finally, the fact of having lived with a partner before imprisonment reduces the risk of forced medication and communication with the family decreases the risk of isolation. Patients subjected to a coercive measure exhibited a pronounced psychopathology and most of them had been subjected to such measures on previous occasions. The mere fact of external assessment of compliance with human rights slows down the incidence of coercive measures.

  18. Variables associated with the use of coercive measures on psychiatric patients in Spanish penitentiary centers.

    Science.gov (United States)

    Girela, E; López, A; Ortega, L; De-Juan, J; Ruiz, F; Bosch, J I; Barrios, L F; Luna, J D; Torres-González, F

    2014-01-01

    We have studied the use of coercive medical measures (forced medication, isolation, and mechanical restraint) in mentally ill inmates within two secure psychiatric hospitals (SPH) and three regular prisons (RP) in Spain. Variables related to adopted coercive measures were analyzed, such as type of measure, causes of indication, opinion of patient inmate, opinion of medical staff, and more frequent morbidity. A total of 209 patients (108 from SPH and 101 from RP) were studied. Isolation (41.35%) was the most frequent coercive measure, followed by mechanical restraint (33.17%) and forced medication (25.48%). The type of center has some influence; specifically in RP there is less risk of isolation and restraint than in SPH. Not having had any previous imprisonment reduces isolation and restraint risk while increases the risk of forced medication, as well as previous admissions to psychiatric inpatient units does. Finally, the fact of having lived with a partner before imprisonment reduces the risk of forced medication and communication with the family decreases the risk of isolation. Patients subjected to a coercive measure exhibited a pronounced psychopathology and most of them had been subjected to such measures on previous occasions. The mere fact of external assessment of compliance with human rights slows down the incidence of coercive measures.

  19. Continuous-variable quantum teleportation with non-Gaussian resources

    International Nuclear Information System (INIS)

    Dell'Anno, F.; De Siena, S.; Albano, L.; Illuminati, F.

    2007-01-01

    We investigate continuous variable quantum teleportation using non-Gaussian states of the radiation field as entangled resources. We compare the performance of different classes of degaussified resources, including two-mode photon-added and two-mode photon-subtracted squeezed states. We then introduce a class of two-mode squeezed Bell-like states with one-parameter dependence for optimization. These states interpolate between and include as subcases different classes of degaussified resources. We show that optimized squeezed Bell-like resources yield a remarkable improvement in the fidelity of teleportation both for coherent and nonclassical input states. The investigation reveals that the optimal non-Gaussian resources for continuous variable teleportation are those that most closely realize the simultaneous maximization of the content of entanglement, the degree of affinity with the two-mode squeezed vacuum, and the, suitably measured, amount of non-Gaussianity

  20. Imaging Variable Stars with HST

    Science.gov (United States)

    Karovska, M.

    2012-06-01

    (Abstract only) The Hubble Space Telescope (HST) observations of astronomical sources, ranging from objects in our solar system to objects in the early Universe, have revolutionized our knowledge of the Universe its origins and contents. I highlight results from HST observations of variable stars obtained during the past twenty or so years. Multiwavelength observations of numerous variable stars and stellar systems were obtained using the superb HST imaging capabilities and its unprecedented angular resolution, especially in the UV and optical. The HST provided the first detailed images probing the structure of variable stars including their atmospheres and circumstellar environments. AAVSO observations and light curves have been critical for scheduling of many of these observations and provided important information and context for understanding of the imaging results of many variable sources. I describe the scientific results from the imaging observations of variable stars including AGBs, Miras, Cepheids, semiregular variables (including supergiants and giants), YSOs and interacting stellar systems with a variable stellar components. These results have led to an unprecedented understanding of the spatial and temporal characteristics of these objects and their place in the stellar evolutionary chains, and in the larger context of the dynamic evolving Universe.

  1. Diurnal variability in riverine dissolved organic matter composition determined by in situ optical measurement in the San Joaquin River (California, USA)

    Science.gov (United States)

    Spencer, R.G.M.; Pellerin, B.A.; Bergamaschi, B.A.; Downing, B.D.; Kraus, T.E.C.; Smart, D.R.; Dahlgren, R.A.; Hernes, P.J.

    2007-01-01

    Dissolved organic matter (DOM) concentration and composition in riverine and stream systems are known to vary with hydrological and productivity cycles over the annual and interannual time scales. Rivers are commonly perceived as homogeneous with respect to DOM concentration and composition, particularly under steady flow conditions over short time periods. However, few studies have evaluated the impact of short term variability ( DOC) measurement alone. The in situ optical measurements described in this study clearly showed for the first time diurnal variations in DOM measurements, which have previously been related to both composition and concentration, even though diurnal changes were not well reflected in bulk DOC concentrations. An apparent asynchronous trend of DOM absorbance and chlorophyll-a in comparison to chromophoric dissolved organic matter (CDOM) fluorescence and spectral slope S290-350 suggests that no one specific CDOM spectrophotometric measurement explains absolutely DOM diurnal variation in this system; the measurement of multiple optical parameters is therefore recommended. The observed diurnal changes in DOM composition, measured by in situ optical instrumentation likely reflect both photochemical and biologically-mediated processes. The results of this study highlight that short-term variability in DOM composition may complicate trends for studies aiming to distinguish different DOM sources in riverine systems and emphasizes the importance of sampling specific study sites to be compared at the same time of day. The utilization of in situ optical technology allows short-term variability in DOM dynamics to be monitored and serves to increase our understanding of its processing and fundamental role in the aquatic environment. Copyright ?? 2007 John Wiley & Sons, Ltd.

  2. Iwamoto-Harada coalescence/pickup model for cluster emission: state density approach including angular momentum variables

    Directory of Open Access Journals (Sweden)

    Běták Emil

    2014-04-01

    Full Text Available For low-energy nuclear reactions well above the resonance region, but still below the pion threshold, statistical pre-equilibrium models (e.g., the exciton and the hybrid ones are a frequent tool for analysis of energy spectra and the cross sections of cluster emission. For α’s, two essentially distinct approaches are popular, namely the preformed one and the different versions of coalescence approaches, whereas only the latter group of models can be used for other types of cluster ejectiles. The original Iwamoto-Harada model of pre-equilibrium cluster emission was formulated using the overlap of the cluster and its constituent nucleons in momentum space. Transforming it into level or state densities is not a straigthforward task; however, physically the same model was presented at a conference on reaction models five years earlier. At that time, only the densities without spin were used. The introduction of spin variables into the exciton model enabled detailed calculation of the γ emission and its competition with nucleon channels, and – at the same time – it stimulated further developments of the model. However – to the best of our knowledge – no spin formulation has been presented for cluster emission till recently, when the first attempts have been reported, but restricted to the first emission only. We have updated this effort now and we are able to handle (using the same simplifications as in our previous work pre-equilibrium cluster emission with spin including all nuclei in the reaction chain.

  3. Seasonal variability of the Red Sea, from GRACE time-variable gravity and altimeter sea surface height measurements

    Science.gov (United States)

    Wahr, John; Smeed, David; Leuliette, Eric; Swenson, Sean

    2014-05-01

    Seasonal variability of sea surface height and mass within the Red Sea, occurs mostly through the exchange of heat with the atmosphere and wind-driven inflow and outflow of water through the strait of Bab el Mandab that opens into the Gulf of Aden to the south. The seasonal effects of precipitation and evaporation, of water exchange through the Suez Canal to the north, and of runoff from the adjacent land, are all small. The flow through the Bab el Mandab involves a net mass transfer into the Red Sea during the winter and a net transfer out during the summer. But that flow has a multi-layer pattern, so that in the summer there is actually an influx of cool water at intermediate (~100 m) depths. Thus, summer water in the southern Red Sea is warmer near the surface due to higher air temperatures, but cooler at intermediate depths (especially in the far south). Summer water in the northern Red Sea experiences warming by air-sea exchange only. The temperature profile affects the water density, which impacts the sea surface height but has no effect on vertically integrated mass. Here, we study this seasonal cycle by combining GRACE time-variable mass estimates, altimeter (Jason-1, Jason-2, and Envisat) measurements of sea surface height, and steric sea surface height contributions derived from depth-dependent, climatological values of temperature and salinity obtained from the World Ocean Atlas. We find good consistency, particularly in the northern Red Sea, between these three data types. Among the general characteristics of our results are: (1) the mass contributions to seasonal SSHT variations are much larger than the steric contributions; (2) the mass signal is largest in winter, consistent with winds pushing water into the Red Sea through the Strait of Bab el Mandab in winter, and out during the summer; and (3) the steric signal is largest in summer, consistent with summer sea surface warming.

  4. Effect of variable measurement coil displacement on the determination of the harmonic content of a multipole

    International Nuclear Information System (INIS)

    Halbach, K.

    1976-01-01

    When one measures the harmonic content of a two dimensional field it is important that the measurement equipment does not simulate harmonics that are not present in the field. Of the several sources that can lead to this kind of false data, we discuss here the error caused by a displacement of the axis of rotation of the measuring coil system that varies with the rotation angle of the measuring system. The two most prominent reasons for such variable axis displacements are probably imperfect bearings, and bending of the coil support structure due to either gravity or imperfectly aligned bearings. In both cases, the displacement may vary along the length of the coil. However, since we are dealing with very small displacements, the treatment of the problem with two dimensional field analysis should be perfectly adequate to understand what the consequences are, and to calculate them quantitatively

  5. Introduction to statistical modelling 2: categorical variables and interactions in linear regression.

    Science.gov (United States)

    Lunt, Mark

    2015-07-01

    In the first article in this series we explored the use of linear regression to predict an outcome variable from a number of predictive factors. It assumed that the predictive factors were measured on an interval scale. However, this article shows how categorical variables can also be included in a linear regression model, enabling predictions to be made separately for different groups and allowing for testing the hypothesis that the outcome differs between groups. The use of interaction terms to measure whether the effect of a particular predictor variable differs between groups is also explained. An alternative approach to testing the difference between groups of the effect of a given predictor, which consists of measuring the effect in each group separately and seeing whether the statistical significance differs between the groups, is shown to be misleading. © The Author 2013. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Partitioning the variability of fasting plasma glucose levels in pedigrees. Genetic and environmental factors.

    Science.gov (United States)

    Boehnke, M; Moll, P P; Kottke, B A; Weidman, W H

    1987-04-01

    Fasting plasma glucose measurements made in 1972-1977 on normoglycemic individuals in three-generation Caucasian pedigrees from Rochester, Minnesota were analyzed. The authors determined the contributions of polygenic loci and environmental factors to fasting plasma glucose variability in these pedigrees. To that end, fasting plasma glucose measurements were normalized by an inverse normal scores transformation and then regressed separately for males and females on measured concomitants including age, body mass index (weight/height2), season of measurement, sex hormone use, and diuretic use. The authors found that 27.7% of the variability in normalized fasting plasma glucose in these pedigrees is explained by these measured concomitants. Subsequent variance components analysis suggested that unmeasured polygenic loci and unmeasured shared environmental factors together account for at least an additional 36.7% of the variability in normalized fasting plasma glucose, with genes alone accounting for at least 27.3%. These results are consistent with the known familiality of diabetes, for which fasting plasma glucose level is an important predictor. Further, these familial factors provide an explanation for at least half the variability in normalized fasting plasma glucose which remains after regression on known concomitants.

  7. Measurement Variability of Vertical Scanning Interferometry Tool Used for Orbiter Window Defect Assessment

    Science.gov (United States)

    Padula, Santo, II

    2009-01-01

    The ability to sufficiently measure orbiter window defects to allow for window recertification has been an ongoing challenge for the orbiter vehicle program. The recent Columbia accident has forced even tighter constraints on the criteria that must be met in order to recertify windows for flight. As a result, new techniques are being investigated to improve the reliability, accuracy and resolution of the defect detection process. The methodology devised in this work, which is based on the utilization of a vertical scanning interferometric (VSI) tool, shows great promise for meeting the ever increasing requirements for defect detection. This methodology has the potential of a 10-100 fold greater resolution of the true defect depth than can be obtained from the currently employed micrometer based methodology. An added benefit is that it also produces a digital elevation map of the defect, thereby providing information about the defect morphology which can be utilized to ascertain the type of debris that induced the damage. However, in order to successfully implement such a tool, a greater understanding of the resolution capability and measurement repeatability must be obtained. This work focused on assessing the variability of the VSI-based measurement methodology and revealed that the VSI measurement tool was more repeatable and more precise than the current micrometer based approach, even in situations where operator variation could affect the measurement. The analysis also showed that the VSI technique was relatively insensitive to the hardware and software settings employed, making the technique extremely robust and desirable

  8. PaCAL: A Python Package for Arithmetic Computations with Random Variables

    Directory of Open Access Journals (Sweden)

    Marcin Korze?

    2014-05-01

    Full Text Available In this paper we present PaCAL, a Python package for arithmetical computations on random variables. The package is capable of performing the four arithmetic operations: addition, subtraction, multiplication and division, as well as computing many standard functions of random variables. Summary statistics, random number generation, plots, and histograms of the resulting distributions can easily be obtained and distribution parameter ?tting is also available. The operations are performed numerically and their results interpolated allowing for arbitrary arithmetic operations on random variables following practically any probability distribution encountered in practice. The package is easy to use, as operations on random variables are performed just as they are on standard Python variables. Independence of random variables is, by default, assumed on each step but some computations on dependent random variables are also possible. We demonstrate on several examples that the results are very accurate, often close to machine precision. Practical applications include statistics, physical measurements or estimation of error distributions in scienti?c computations.

  9. The reliability of linear position transducer, force plate and combined measurement of explosive power-time variables during a loaded jump squat in elite athletes.

    Science.gov (United States)

    Hansen, Keir T; Cronin, John B; Newton, Michael J

    2011-03-01

    The purpose of this study was to determine the between day reliability of power-time measures calculated with data collected using the linear position transducer or the force plate independently, or a combination of the two technologies. Twenty-five male rugby union players performed three jump squats on two occasions one week apart. Ground reaction forces were measured via a force plate and position data were collected using a linear position transducer. From these data, a number of power-time variables were calculated for each method. The force plate, linear position transducer and a combined method were all found to be a reliable means of measuring peak power (ICC = 0.87-0.95, CV = 3.4%-8.0%). The absolute consistency of power-time measures varied between methods (CV = 8.0%-53.4%). Relative consistency of power-time measures was generally comparable between methods and measures, and for many variables was at an acceptable level (ICC = 0.77-0.94). Although a number of time-dependent power variables can be reliably calculated from data acquired from the three methods investigated, the reliability of a number of these measures is below that which is acceptable for use in research and for practical applications.

  10. Earth System Data Records of Mass Transport from Time-Variable Gravity Data

    Science.gov (United States)

    Zlotnicki, V.; Talpe, M.; Nerem, R. S.; Landerer, F. W.; Watkins, M. M.

    2014-12-01

    Satellite measurements of time variable gravity have revolutionized the study of Earth, by measuring the ice losses of Greenland, Antarctica and land glaciers, changes in groundwater including unsustainable losses due to extraction of groundwater, the mass and currents of the oceans and their redistribution during El Niño events, among other findings. Satellite measurements of gravity have been made primarily by four techniques: satellite tracking from land stations using either lasers or Doppler radio systems, satellite positioning by GNSS/GPS, satellite to satellite tracking over distances of a few hundred km using microwaves, and through a gravity gradiometer (radar altimeters also measure the gravity field, but over the oceans only). We discuss the challenges in the measurement of gravity by different instruments, especially time-variable gravity. A special concern is how to bridge a possible gap in time between the end of life of the current GRACE satellite pair, launched in 2002, and a future GRACE Follow-On pair to be launched in 2017. One challenge in combining data from different measurement systems consists of their different spatial and temporal resolutions and the different ways in which they alias short time scale signals. Typically satellite measurements of gravity are expressed in spherical harmonic coefficients (although expansions in terms of 'mascons', the masses of small spherical caps, has certain advantages). Taking advantage of correlations among spherical harmonic coefficients described by empirical orthogonal functions and derived from GRACE data it is possible to localize the otherwise coarse spatial resolution of the laser and Doppler derived gravity models. This presentation discusses the issues facing a climate data record of time variable mass flux using these different data sources, including its validation.

  11. Variable volume combustor

    Science.gov (United States)

    Ostebee, Heath Michael; Ziminsky, Willy Steve; Johnson, Thomas Edward; Keener, Christopher Paul

    2017-01-17

    The present application provides a variable volume combustor for use with a gas turbine engine. The variable volume combustor may include a liner, a number of micro-mixer fuel nozzles positioned within the liner, and a linear actuator so as to maneuver the micro-mixer fuel nozzles axially along the liner.

  12. Practical performance of real-time shot-noise measurement in continuous-variable quantum key distribution

    Science.gov (United States)

    Wang, Tao; Huang, Peng; Zhou, Yingming; Liu, Weiqi; Zeng, Guihua

    2018-01-01

    In a practical continuous-variable quantum key distribution (CVQKD) system, real-time shot-noise measurement (RTSNM) is an essential procedure for preventing the eavesdropper exploiting the practical security loopholes. However, the performance of this procedure itself is not analyzed under the real-world condition. Therefore, we indicate the RTSNM practical performance and investigate its effects on the CVQKD system. In particular, due to the finite-size effect, the shot-noise measurement at the receiver's side may decrease the precision of parameter estimation and consequently result in a tight security bound. To mitigate that, we optimize the block size for RTSNM under the ensemble size limitation to maximize the secure key rate. Moreover, the effect of finite dynamics of amplitude modulator in this scheme is studied and its mitigation method is also proposed. Our work indicates the practical performance of RTSNM and provides the real secret key rate under it.

  13. Gait variability: methods, modeling and meaning

    Directory of Open Access Journals (Sweden)

    Hausdorff Jeffrey M

    2005-07-01

    Full Text Available Abstract The study of gait variability, the stride-to-stride fluctuations in walking, offers a complementary way of quantifying locomotion and its changes with aging and disease as well as a means of monitoring the effects of therapeutic interventions and rehabilitation. Previous work has suggested that measures of gait variability may be more closely related to falls, a serious consequence of many gait disorders, than are measures based on the mean values of other walking parameters. The Current JNER series presents nine reports on the results of recent investigations into gait variability. One novel method for collecting unconstrained, ambulatory data is reviewed, and a primer on analysis methods is presented along with a heuristic approach to summarizing variability measures. In addition, the first studies of gait variability in animal models of neurodegenerative disease are described, as is a mathematical model of human walking that characterizes certain complex (multifractal features of the motor control's pattern generator. Another investigation demonstrates that, whereas both healthy older controls and patients with a higher-level gait disorder walk more slowly in reduced lighting, only the latter's stride variability increases. Studies of the effects of dual tasks suggest that the regulation of the stride-to-stride fluctuations in stride width and stride time may be influenced by attention loading and may require cognitive input. Finally, a report of gait variability in over 500 subjects, probably the largest study of this kind, suggests how step width variability may relate to fall risk. Together, these studies provide new insights into the factors that regulate the stride-to-stride fluctuations in walking and pave the way for expanded research into the control of gait and the practical application of measures of gait variability in the clinical setting.

  14. Variability in individual activity bursts improves ant foraging success.

    Science.gov (United States)

    Campos, Daniel; Bartumeus, Frederic; Méndez, Vicenç; Andrade, José S; Espadaler, Xavier

    2016-12-01

    Using experimental and computational methods, we study the role of behavioural variability in activity bursts (or temporal activity patterns) for individual and collective regulation of foraging in A. senilis ants. First, foraging experiments were carried out under special conditions (low densities of ants and food and absence of external cues or stimuli) where individual-based strategies are most prevalent. By using marked individuals and recording all foraging trajectories, we were then able to precisely quantify behavioural variability among individuals. Our main conclusions are that (i) variability of ant trajectories (turning angles, speed, etc.) is low compared with variability of temporal activity profiles, and (ii) this variability seems to be driven by plasticity of individual behaviour through time, rather than the presence of fixed behavioural stereotypes or specialists within the group. The statistical measures obtained from these experimental foraging patterns are then used to build a general agent-based model (ABM) which includes the most relevant properties of ant foraging under natural conditions, including recruitment through pheromone communication. Using the ABM, we are able to provide computational evidence that the characteristics of individual variability observed in our experiments can provide a functional advantage (in terms of foraging success) to the group; thus, we propose the biological basis underpinning our observations. Altogether, our study reveals the potential utility of experiments under simplified (laboratory) conditions for understanding information-gathering in biological systems. © 2016 The Author(s).

  15. Measuring the environmental effects of organic farming: A meta-analysis of structural variables in empirical research.

    Science.gov (United States)

    Lee, Ki Song; Choe, Young Chan; Park, Sung Hee

    2015-10-01

    This study examined the structural variables affecting the environmental effects of organic farming compared to those of conventional farming. A meta-analysis based on 107 studies and 360 observations published from 1977 to 2012 compared energy efficiency (EE) and greenhouse gas emissions (GHGE) for organic and conventional farming. The meta-analysis systematically analyzed the results of earlier comparative studies and used logistic regression to identify the structural variables that contributed to differences in the effects of organic and conventional farming on the environment. The statistical evidence identified characteristics that differentiated the environmental effects of organic and conventional farming, which is controversial. The results indicated that data sources, sample size and product type significantly affected EE, whereas product type, cropping pattern and measurement unit significantly affected the GHGE of organic farming compared to conventional farming. Superior effects of organic farming on the environment were more likely to appear for larger samples, primary data rather than secondary data, monocropping rather than multicropping, and crops other than fruits and vegetables. The environmental effects of organic farming were not affected by the study period, geographic location, farm size, cropping pattern, or measurement method. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Finite-size analysis of continuous-variable measurement-device-independent quantum key distribution

    Science.gov (United States)

    Zhang, Xueying; Zhang, Yichen; Zhao, Yijia; Wang, Xiangyu; Yu, Song; Guo, Hong

    2017-10-01

    We study the impact of the finite-size effect on the continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol, mainly considering the finite-size effect on the parameter estimation procedure. The central-limit theorem and maximum likelihood estimation theorem are used to estimate the parameters. We also analyze the relationship between the number of exchanged signals and the optimal modulation variance in the protocol. It is proved that when Charlie's position is close to Bob, the CV-MDI QKD protocol has the farthest transmission distance in the finite-size scenario. Finally, we discuss the impact of finite-size effects related to the practical detection in the CV-MDI QKD protocol. The overall results indicate that the finite-size effect has a great influence on the secret-key rate of the CV-MDI QKD protocol and should not be ignored.

  17. Heart rate variability measurement and clinical depression in acute coronary syndrome patients: narrative review of recent literature

    Directory of Open Access Journals (Sweden)

    Harris PR

    2014-07-01

    Full Text Available Patricia RE Harris,1 Claire E Sommargren,2 Phyllis K Stein,3 Gordon L Fung,4,5 Barbara J Drew6,7 1ECG Monitoring Research Lab, 2Department of Physiological Nursing, School of Nursing, University of California, San Francisco, CA, USA; 3Heart Rate Variability Laboratory, School of Medicine, Washington University, St Louis, MO, USA; 4Asian Heart & Vascular Center at Mount Zion, Division of Cardiology, University of California, 5Cardiology Consultation Service, Cardiac Noninvasive Laboratory, and The Enhanced External Counterpulsation Unit, Department of Medicine, University of California, San Francisco Medical Center, 6Division of Cardiology, 7Department of Physiological Nursing, School of Nursing, University of California, San Francisco, CA, USA Aim: We aimed to explore links between heart rate variability (HRV and clinical depression in patients with acute coronary syndrome (ACS, through a review of recent clinical research literature. Background: Patients with ACS are at risk for both cardiac autonomic dysfunction and clinical depression. Both conditions can negatively impact the ability to recover from an acute physiological insult, such as unstable angina or myocardial infarction, increasing the risk for adverse cardiovascular outcomes. HRV is recognized as a reflection of autonomic function. Methods: A narrative review was undertaken to evaluate state-of-the-art clinical research, using the PubMed database, January 2013. The search terms “heart rate variability” and “depression” were used in conjunction with “acute coronary syndrome”, “unstable angina”, or “myocardial infarction” to find clinical studies published within the past 10 years related to HRV and clinical depression, in patients with an ACS episode. Studies were included if HRV measurement and depression screening were undertaken during an ACS hospitalization or within 2 months of hospital discharge. Results: Nine clinical studies met the inclusion criteria. The

  18. The Performance of Variable Annuities

    OpenAIRE

    Michael J. McNamara; Henry R. Oppenheimer

    1991-01-01

    Variable annuities have become increasingly important in retirement plans. This paper provides an examination of the investment performance of variable annuities for the period year-end 1973 to year-end 1988. Returns, risk, and selectivity measures are analyzed for the sample of annuities, for individual variable annuities, and for subsamples of annuities with similar portfolio size and turnover. While the investment returns of variable annuities were greater than inflation over the period, t...

  19. Latent variables and route choice behavior

    DEFF Research Database (Denmark)

    Prato, Carlo Giacomo; Bekhor, Shlomo; Pronello, Cristina

    2012-01-01

    In the last decade, a broad array of disciplines has shown a general interest in enhancing discrete choice models by considering the incorporation of psychological factors affecting decision making. This paper provides insight into the comprehension of the determinants of route choice behavior...... and bound algorithm. A hybrid model consists of measurement equations, which relate latent variables to measurement indicators and utilities to choice indicators, and structural equations, which link travelers’ observable characteristics to latent variables and explanatory variables to utilities. Estimation...

  20. CameraHRV: robust measurement of heart rate variability using a camera

    Science.gov (United States)

    Pai, Amruta; Veeraraghavan, Ashok; Sabharwal, Ashutosh

    2018-02-01

    The inter-beat-interval (time period of the cardiac cycle) changes slightly for every heartbeat; this variation is measured as Heart Rate Variability (HRV). HRV is presumed to occur due to interactions between the parasym- pathetic and sympathetic nervous system. Therefore, it is sometimes used as an indicator of the stress level of an individual. HRV also reveals some clinical information about cardiac health. Currently, HRV is accurately measured using contact devices such as a pulse oximeter. However, recent research in the field of non-contact imaging Photoplethysmography (iPPG) has made vital sign measurements using just the video recording of any exposed skin (such as a person's face) possible. The current signal processing methods for extracting HRV using peak detection perform well for contact-based systems but have poor performance for the iPPG signals. The main reason for this poor performance is the fact that current methods are sensitive to large noise sources which are often present in iPPG data. Further, current methods are not robust to motion artifacts that are common in iPPG systems. We developed a new algorithm, CameraHRV, for robustly extracting HRV even in low SNR such as is common with iPPG recordings. CameraHRV combined spatial combination and frequency demodulation to obtain HRV from the instantaneous frequency of the iPPG signal. CameraHRV outperforms other current methods of HRV estimation. Ground truth data was obtained from FDA-approved pulse oximeter for validation purposes. CameraHRV on iPPG data showed an error of 6 milliseconds for low motion and varying skin tone scenarios. The improvement in error was 14%. In case of high motion scenarios like reading, watching and talking, the error was 10 milliseconds.

  1. Measuring behaviours for escaping from house fires: use of latent variable models to summarise multiple behaviours.

    Science.gov (United States)

    Ploubidis, G B; Edwards, P; Kendrick, D

    2015-12-15

    This paper reports the development and testing of a construct measuring parental fire safety behaviours for planning escape from a house fire. Latent variable modelling of data on parental-reported fire safety behaviours and plans for escaping from a house fire and multivariable logistic regression to quantify the association between groups defined by the latent variable modelling and parental-report of having a plan for escaping from a house fire. Data comes from 1112 participants in a cluster randomised controlled trial set in children's centres in 4 study centres in the UK. A two class model provided the best fit to the data, combining responses to five fire safety planning behaviours. The first group ('more behaviours for escaping from a house fire') comprised 86% of participants who were most likely to have a torch, be aware of how their smoke alarm sounds, to have external door and window keys accessible, and exits clear. The second group ('fewer behaviours for escaping from a house fire') comprised 14% of participants who were less likely to report these five behaviours. After adjusting for potential confounders, participants allocated to the 'more behaviours for escaping from a house fire group were 2.5 times more likely to report having an escape plan (OR 2.48; 95% CI 1.59-3.86) than those in the "fewer behaviours for escaping from a house fire" group. Multiple fire safety behaviour questions can be combined into a single binary summary measure of fire safety behaviours for escaping from a house fire. Our findings will be useful to future studies wishing to use a single measure of fire safety planning behaviour as measures of outcome or exposure. NCT 01452191. Date of registration 13/10/2011.

  2. Variable mechanical ventilation.

    Science.gov (United States)

    Fontela, Paula Caitano; Prestes, Renata Bernardy; Forgiarini, Luiz Alberto; Friedman, Gilberto

    2017-01-01

    To review the literature on the use of variable mechanical ventilation and the main outcomes of this technique. Search, selection, and analysis of all original articles on variable ventilation, without restriction on the period of publication and language, available in the electronic databases LILACS, MEDLINE®, and PubMed, by searching the terms "variable ventilation" OR "noisy ventilation" OR "biologically variable ventilation". A total of 36 studies were selected. Of these, 24 were original studies, including 21 experimental studies and three clinical studies. Several experimental studies reported the beneficial effects of distinct variable ventilation strategies on lung function using different models of lung injury and healthy lungs. Variable ventilation seems to be a viable strategy for improving gas exchange and respiratory mechanics and preventing lung injury associated with mechanical ventilation. However, further clinical studies are necessary to assess the potential of variable ventilation strategies for the clinical improvement of patients undergoing mechanical ventilation.

  3. Glenoid version by CT scan: an analysis of clinical measurement error and introduction of a protocol to reduce variability

    Energy Technology Data Exchange (ETDEWEB)

    Bunt, Fabian van de [VU University Medical Center, Amsterdam (Netherlands); Pearl, Michael L.; Lee, Eric K.; Peng, Lauren; Didomenico, Paul [Kaiser Permanente, Los Angeles, CA (United States)

    2015-11-15

    Recent studies have challenged the accuracy of conventional measurements of glenoid version. Variability in the orientation of the scapula from individual anatomical differences and patient positioning, combined with differences in observer measurement practices, have been identified as sources of variability. The purpose of this study was to explore the utility and reliability of clinically available software that allows manipulation of three-dimensional images in order to bridge the variance between clinical and anatomic version in a clinical setting. Twenty CT scans of normal glenoids of patients who had proximal humerus fractures were measured for version. Four reviewers first measured version in a conventional manner (clinical version), measurements were made again (anatomic version) after employing a protocol for reformatting the CT data to align the coronal and sagittal planes with the superior-inferior axis of the glenoid, and the scapular body, respectively. The average value of clinical retroversion for all reviewers and all subjects was -1.4 (range, -16 to 21 ), as compared to -3.2 (range, -21 to 6 ) when measured from reformatted images. The mean difference between anatomical and clinical version was 1.9 ± 5.6 but ranged on individual measurements from -13 to 26 . In no instance did all four observers choose the same image slice from the sequence of images. This study confirmed the variation in glenoid version dependent on scapular orientation previously identified in other studies using scapular models, and presents a clinically accessible protocol to correct for scapular orientation from the patient's CT data. (orig.)

  4. Glenoid version by CT scan: an analysis of clinical measurement error and introduction of a protocol to reduce variability

    International Nuclear Information System (INIS)

    Bunt, Fabian van de; Pearl, Michael L.; Lee, Eric K.; Peng, Lauren; Didomenico, Paul

    2015-01-01

    Recent studies have challenged the accuracy of conventional measurements of glenoid version. Variability in the orientation of the scapula from individual anatomical differences and patient positioning, combined with differences in observer measurement practices, have been identified as sources of variability. The purpose of this study was to explore the utility and reliability of clinically available software that allows manipulation of three-dimensional images in order to bridge the variance between clinical and anatomic version in a clinical setting. Twenty CT scans of normal glenoids of patients who had proximal humerus fractures were measured for version. Four reviewers first measured version in a conventional manner (clinical version), measurements were made again (anatomic version) after employing a protocol for reformatting the CT data to align the coronal and sagittal planes with the superior-inferior axis of the glenoid, and the scapular body, respectively. The average value of clinical retroversion for all reviewers and all subjects was -1.4 (range, -16 to 21 ), as compared to -3.2 (range, -21 to 6 ) when measured from reformatted images. The mean difference between anatomical and clinical version was 1.9 ± 5.6 but ranged on individual measurements from -13 to 26 . In no instance did all four observers choose the same image slice from the sequence of images. This study confirmed the variation in glenoid version dependent on scapular orientation previously identified in other studies using scapular models, and presents a clinically accessible protocol to correct for scapular orientation from the patient's CT data. (orig.)

  5. Reproducibility of measurements and variability of the classification algorithm of Stratus OCT in normal, hypertensive, and glaucomatous patients

    Directory of Open Access Journals (Sweden)

    Alfonso Antón

    2009-01-01

    Full Text Available Alfonso Antón1,2,3, Marta Castany1,2, Marta Pazos-Lopez1,2, Ruben Cuadrado3, Ana Flores3, Miguel Castilla11Hospital de la Esperanza-Hospital del Mar (IMAS, Barcelona, Spain; 2Institut Català de la Retina (ICR, Barcelona, Spain. Glaucoma Department; 3Instituto Universitario de Oftalmobiología Aplicada (IOBA, Universidad de Valladolid, Valladolid, EspañaPurpose: To assess the reproducibility of retinal nerve fiber layer (RNFL measurements and the variability of the probabilistic classification algorithm in normal, hypertensive and glaucomatous eyes using Stratus optical coherence tomography (OCT.Methods: Forty-nine eyes (13 normal, 17 ocular hypertensive [OHT] and 19 glaucomatous of 49 subjects were included in this study. RNFL was determined with Stratus OCT using the standard protocol RNFL thickness 3.4. Three different images of each eye were taken consecutively during the same session. To evaluate OCT reproducibility, coefficient of variation (COV and intraclass correlation coefficient (ICC were calculated for average thickness (AvgT, superior average thickness (Savg, and inferior average thickness (Iavg parameters. The variability of the results of the probabilistic classification algorithm, based on the OCT normative database, was also analyzed. The percentage of eyes with changes in the category assigned was calculated for each group.Results: The 50th percentile of COV was 2.96%, 4.00%, and 4.31% for AvgT, Savg, and Iavg, respectively. Glaucoma group presented the largest COV for all three parameters (3.87%, 5.55%, 7.82%. ICC were greater than 0.75 for almost all measures (except from the inferior thickness parameter in the normal group; ICC = 0.64, 95% CI 0.334–0.857. Regarding the probabilistic classification algorithm for the three parameters (AvgT, Savg, Iavg, the percentage of eyes without color-code category changes among the three images was as follows: normal group, 100%, 84.6% and 92%; OHT group, 89.5%, 52.7%, 79%; and

  6. Economic Statistical Design of Variable Sampling Interval X¯$\\overline X $ Control Chart Based on Surrogate Variable Using Genetic Algorithms

    Directory of Open Access Journals (Sweden)

    Lee Tae-Hoon

    2016-12-01

    Full Text Available In many cases, a X¯$\\overline X $ control chart based on a performance variable is used in industrial fields. Typically, the control chart monitors the measurements of a performance variable itself. However, if the performance variable is too costly or impossible to measure, and a less expensive surrogate variable is available, the process may be more efficiently controlled using surrogate variables. In this paper, we present a model for the economic statistical design of a VSI (Variable Sampling Interval X¯$\\overline X $ control chart using a surrogate variable that is linearly correlated with the performance variable. We derive the total average profit model from an economic viewpoint and apply the model to a Very High Temperature Reactor (VHTR nuclear fuel measurement system and derive the optimal result using genetic algorithms. Compared with the control chart based on a performance variable, the proposed model gives a larger expected net income per unit of time in the long-run if the correlation between the performance variable and the surrogate variable is relatively high. The proposed model was confined to the sample mean control chart under the assumption that a single assignable cause occurs according to the Poisson process. However, the model may also be extended to other types of control charts using a single or multiple assignable cause assumptions such as VSS (Variable Sample Size X¯$\\overline X $ control chart, EWMA, CUSUM charts and so on.

  7. EVIDENCE FOR DYNAMICAL CHANGES IN A TRANSITIONAL PROTOPLANETARY DISK WITH MID-INFRARED VARIABILITY

    International Nuclear Information System (INIS)

    Muzerolle, James; Flaherty, Kevin; Balog, Zoltan; Smith, Paul S.; Rieke, George H.; Furlan, Elise; Allen, Lori; Muench, August; Calvet, Nuria; D'Alessio, Paola; Megeath, S. Thomas; Sherry, William H.

    2009-01-01

    We present multi-epoch Spitzer Space Telescope observations of the transitional disk LRLL 31 in the 2-3 Myr old star-forming region IC 348. Our measurements show remarkable mid-infrared variability on timescales as short as one week. The infrared continuum emission exhibits systematic wavelength-dependent changes that suggest corresponding dynamical changes in the inner disk structure and variable shadowing of outer disk material. We propose several possible sources for the structural changes, including a variable accretion rate or a stellar or planetary companion embedded in the disk. Our results indicate that variability studies in the infrared can provide important new constraints on protoplanetary disk behavior.

  8. Estimating variability in placido-based topographic systems.

    Science.gov (United States)

    Kounis, George A; Tsilimbaris, Miltiadis K; Kymionis, George D; Ginis, Harilaos S; Pallikaris, Ioannis G

    2007-10-01

    To describe a new software tool for the detailed presentation of corneal topography measurements variability by means of color-coded maps. Software was developed in Visual Basic to analyze and process a series of 10 consecutive measurements obtained by a topographic system on calibration spheres, and individuals with emmetropic, low, high, and irregular astigmatic corneas. Corneal surface was segmented into 1200 segments and the coefficient of variance of each segment's keratometric dioptric power was used as the measure of variability. The results were presented graphically in color-coded maps (Variability Maps). Two topographic systems, the TechnoMed C-Scan and the TOMEY Topographic Modeling System (TMS-2N), were examined to demonstrate our method. Graphic representation of coefficient of variance offered a detailed representation of examination variability both in calibration surfaces and human corneas. It was easy to recognize an increase in variability, as the irregularity of examination surfaces increased. In individuals with high and irregular astigmatism, a variability pattern correlated with the pattern of corneal topography: steeper corneal areas possessed higher variability values compared with flatter areas of the same cornea. Numerical data permitted direct comparisons and statistical analysis. We propose a method that permits a detailed evaluation of the variability of corneal topography measurements. The representation of the results both graphically and quantitatively improves interpretability and facilitates a spatial correlation of variability maps with original topography maps. Given the popularity of topography based custom refractive ablations of the cornea, it is possible that variability maps may assist clinicians in the evaluation of corneal topography maps of patients with very irregular corneas, before custom ablation procedures.

  9. Heart rate variability in patients with systemic lupus erythematosus: a systematic review and methodological considerations.

    Science.gov (United States)

    Matusik, P S; Matusik, P T; Stein, P K

    2018-07-01

    Aim The aim of this review was to summarize current knowledge about the scientific findings and potential clinical utility of heart rate variability measures in patients with systemic lupus erythematosus. Methods PubMed, Embase and Scopus databases were searched for the terms associated with systemic lupus erythematosus and heart rate variability, including controlled vocabulary, when appropriate. Articles published in English and available in full text were considered. Finally, 11 publications were selected, according to the systematic review protocol and were analyzed. Results In general, heart rate variability, measured in the time and frequency domains, was reported to be decreased in patients with systemic lupus erythematosus compared with controls. In some systemic lupus erythematosus studies, heart rate variability was found to correlate with inflammatory markers and albumin levels. A novel heart rate variability measure, heart rate turbulence onset, was shown to be increased, while heart rate turbulence slope was decreased in systemic lupus erythematosus patients. Reports of associations of changes in heart rate variability parameters with increasing systemic lupus erythematosus activity were inconsistent, showing decreasing heart rate variability or no relationship. However, the low/high frequency ratio was, in some studies, reported to increase with increasing disease activity or to be inversely correlated with albumin levels. Conclusions Patients with systemic lupus erythematosus have abnormal heart rate variability, which reflects cardiac autonomic dysfunction and may be related to inflammatory cytokines but not necessarily to disease activity. Thus measurement of heart rate variability could be a useful clinical tool for monitoring autonomic dysfunction in systemic lupus erythematosus, and may potentially provide prognostic information.

  10. Soil Temperature Variability in Complex Terrain measured using Distributed a Fiber-Optic Distributed Temperature Sensing

    Science.gov (United States)

    Seyfried, M. S.; Link, T. E.

    2013-12-01

    Soil temperature (Ts) exerts critical environmental controls on hydrologic and biogeochemical processes. Rates of carbon cycling, mineral weathering, infiltration and snow melt are all influenced by Ts. Although broadly reflective of the climate, Ts is sensitive to local variations in cover (vegetative, litter, snow), topography (slope, aspect, position), and soil properties (texture, water content), resulting in a spatially and temporally complex distribution of Ts across the landscape. Understanding and quantifying the processes controlled by Ts requires an understanding of that distribution. Relatively few spatially distributed field Ts data exist, partly because traditional Ts data are point measurements. A relatively new technology, fiber optic distributed temperature system (FO-DTS), has the potential to provide such data but has not been rigorously evaluated in the context of remote, long term field research. We installed FO-DTS in a small experimental watershed in the Reynolds Creek Experimental Watershed (RCEW) in the Owyhee Mountains of SW Idaho. The watershed is characterized by complex terrain and a seasonal snow cover. Our objectives are to: (i) evaluate the applicability of fiber optic DTS to remote field environments and (ii) to describe the spatial and temporal variability of soil temperature in complex terrain influenced by a variable snow cover. We installed fiber optic cable at a depth of 10 cm in contrasting snow accumulation and topographic environments and monitored temperature along 750 m with DTS. We found that the DTS can provide accurate Ts data (+/- .4°C) that resolves Ts changes of about 0.03°C at a spatial scale of 1 m with occasional calibration under conditions with an ambient temperature range of 50°C. We note that there are site-specific limitations related cable installation and destruction by local fauna. The FO-DTS provide unique insight into the spatial and temporal variability of Ts in a landscape. We found strong seasonal

  11. A SEARCH FOR L/T TRANSITION DWARFS WITH Pan-STARRS1 AND WISE: DISCOVERY OF SEVEN NEARBY OBJECTS INCLUDING TWO CANDIDATE SPECTROSCOPIC VARIABLES

    International Nuclear Information System (INIS)

    Best, William M. J.; Liu, Michael C.; Magnier, Eugene A.; Aller, Kimberly M.; Burgett, W. S.; Chambers, K. C.; Hodapp, K. W.; Kaiser, N.; Kudritzki, R.-P.; Morgan, J. S.; Tonry, J. L.; Wainscoat, R. J.; Deacon, Niall R.; Dupuy, Trent J.; Redstone, Joshua; Price, P. A.

    2013-01-01

    We present initial results from a wide-field (30,000 deg 2 ) search for L/T transition brown dwarfs within 25 pc using the Pan-STARRS1 and Wide-field Infrared Survey Explorer (WISE) surveys. Previous large-area searches have been incomplete for L/T transition dwarfs, because these objects are faint in optical bands and have near-infrared (near-IR) colors that are difficult to distinguish from background stars. To overcome these obstacles, we have cross-matched the Pan-STARRS1 (optical) and WISE (mid-IR) catalogs to produce a unique multi-wavelength database for finding ultracool dwarfs. As part of our initial discoveries, we have identified seven brown dwarfs in the L/T transition within 9-15 pc of the Sun. The L9.5 dwarf PSO J140.2308+45.6487 and the T1.5 dwarf PSO J307.6784+07.8263 (both independently discovered by Mace et al.) show possible spectroscopic variability at the Y and J bands. Two more objects in our sample show evidence of photometric J-band variability, and two others are candidate unresolved binaries based on their spectra. We expect our full search to yield a well-defined, volume-limited sample of L/T transition dwarfs that will include many new targets for study of this complex regime. PSO J307.6784+07.8263 in particular may be an excellent candidate for in-depth study of variability, given its brightness (J = 14.2 mag) and proximity (11 pc)

  12. Virtual continuity of measurable functions and its applications

    Science.gov (United States)

    Vershik, A. M.; Zatitskii, P. B.; Petrov, F. V.

    2014-12-01

    A classical theorem of Luzin states that a measurable function of one real variable is `almost' continuous. For measurable functions of several variables the analogous statement (continuity on a product of sets having almost full measure) does not hold in general. The search for a correct analogue of Luzin's theorem leads to a notion of virtually continuous functions of several variables. This apparently new notion implicitly appears in the statements of embedding theorems and trace theorems for Sobolev spaces. In fact it reveals the nature of such theorems as statements about virtual continuity. The authors' results imply that under the conditions of Sobolev theorems there is a well-defined integration of a function with respect to a wide class of singular measures, including measures concentrated on submanifolds. The notion of virtual continuity is also used for the classification of measurable functions of several variables and in some questions on dynamical systems, the theory of polymorphisms, and bistochastic measures. In this paper the necessary definitions and properties of admissible metrics are recalled, several definitions of virtual continuity are given, and some applications are discussed. Bibliography: 24 titles.

  13. Gas permeation measurement under defined humidity via constant volume/variable pressure method

    KAUST Repository

    Jan Roman, Pauls

    2012-02-01

    Many industrial gas separations in which membrane processes are feasible entail high water vapour contents, as in CO 2-separation from flue gas in carbon capture and storage (CCS), or in biogas/natural gas processing. Studying the effect of water vapour on gas permeability through polymeric membranes is essential for materials design and optimization of these membrane applications. In particular, for amine-based CO 2 selective facilitated transport membranes, water vapour is necessary for carrier-complex formation (Matsuyama et al., 1996; Deng and Hägg, 2010; Liu et al., 2008; Shishatskiy et al., 2010) [1-4]. But also conventional polymeric membrane materials can vary their permeation behaviour due to water-induced swelling (Potreck, 2009) [5]. Here we describe a simple approach to gas permeability measurement in the presence of water vapour, in the form of a modified constant volume/variable pressure method (pressure increase method). © 2011 Elsevier B.V.

  14. Cryotherapy, Sensation, and Isometric-Force Variability

    Science.gov (United States)

    Denegar, Craig R.; Buckley, William E.; Newell, Karl M.

    2003-01-01

    Objective: To determine the changes in sensation of pressure, 2-point discrimination, and submaximal isometric-force production variability due to cryotherapy. Design and Setting: Sensation was assessed using a 2 × 2 × 2 × 3 repeated-measures factorial design, with treatment (ice immersion or control), limb (right or left), digit (finger or thumb), and sensation test time (baseline, posttreatment, or postisometric-force trials) as independent variables. Dependent variables were changes in sensation of pressure and 2-point discrimination. Isometric-force variability was tested with a 2 × 2 × 3 repeated-measures factorial design. Treatment condition (ice immersion or control), limb (right or left), and percentage (10, 25, or 40) of maximal voluntary isometric contraction (MVIC) were the independent variables. The dependent variables were the precision or variability (the standard deviation of mean isometric force) and the accuracy or targeting error (the root mean square error) of the isometric force for each percentage of MVIC. Subjects: Fifteen volunteer college students (8 men, 7 women; age = 22 ± 3 years; mass = 72 ± 21.9 kg; height = 183.4 ± 11.6 cm). Measurements: We measured sensation in the distal palmar aspect of the index finger and thumb. Sensation of pressure and 2-point discrimination were measured before treatment (baseline), after treatment (15 minutes of ice immersion or control), and at the completion of isometric testing (final). Variability (standard deviation of mean isometric force) of the submaximal isometric finger forces was measured by having the subjects exert a pinching force with the thumb and index finger for 30 seconds. Subjects performed the pinching task at the 3 submaximal levels of MVIC (10%, 25%, and 40%), with the order of trials assigned randomly. The subjects were given a target representing the submaximal percentage of MVIC and visual feedback of the force produced as they pinched the testing device. The force exerted

  15. Variability of standard artificial soils: Physico-chemical properties and phenanthrene desorption measured by means of supercritical fluid extraction

    International Nuclear Information System (INIS)

    Bielská, Lucie; Hovorková, Ivana; Komprdová, Klára; Hofman, Jakub

    2012-01-01

    The study is focused on artificial soil which is supposed to be a standardized “soil like” medium. We compared physico-chemical properties and extractability of Phenanthrene from 25 artificial soils prepared according to OECD standardized procedures at different laboratories. A substantial range of soil properties was found, also for parameters which should be standardized because they have an important influence on the bioavailability of pollutants (e.g. total organic carbon ranged from 1.4 to 6.1%). The extractability of Phe was measured by supercritical fluid extraction (SFE) at harsh and mild conditions. Highly variable Phe extractability from different soils (3–89%) was observed. The extractability was strongly related (R 2 = 0.87) to total organic carbon content, 0.1–2 mm particle size, and humic/fulvic acid ratio in the following multiple regression model: SFE (%) = 1.35 * sand (%) − 0.77 * TOC (%)2 + 0.27 * HA/FA. - Highlights: ► We compared properties and extractability of Phe from 25 different artificial soils. ► Substantial range of soil properties was found, also for important parameters. ► Phe extractability was measured by supercritical fluid extraction (SFE) at 2 modes. ► Phe extractability was highly variable from different soils (3–89%). ► Extractability was strongly related to TOC, 0.1–2 mm particles, and HA/FA. - Significant variability in physico-chemical properties exists between artificial soils prepared at different laboratories and affects behavior of contaminants in these soils.

  16. Measuring Outcomes in Adult Weight Loss Studies That Include Diet and Physical Activity: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Rachel A. Millstein

    2014-01-01

    Full Text Available Background. Measuring success of obesity interventions is critical. Several methods measure weight loss outcomes but there is no consensus on best practices. This systematic review evaluates relevant outcomes (weight loss, BMI, % body fat, and fat mass to determine which might be the best indicator(s of success. Methods. Eligible articles described adult weight loss interventions that included diet and physical activity and a measure of weight or BMI change and body composition change. Results. 28 full-text articles met inclusion criteria. Subjects, settings, intervention lengths, and intensities varied. All studies measured body weight (−2.9 to −17.3 kg, 9 studies measured BMI (−1.1 to −5.1 kg/m2, 20 studies measured % body fat (−0.7 to −10.2%, and 22 studies measured fat mass (−0.9 to −14.9 kg. All studies found agreement between weight or BMI and body fat mass or body fat % decreases, though there were discrepancies in degree of significance between measures. Conclusions. Nearly all weight or BMI and body composition measures agreed. Since body fat is the most metabolically harmful tissue type, it may be a more meaningful measure of health change. Future studies should consider primarily measuring % body fat, rather than or in addition to weight or BMI.

  17. Eddy covariance flux measurements confirm extreme CH4 emissions from a Swiss hydropower reservoir and resolve their short-term variability

    Directory of Open Access Journals (Sweden)

    S. Sobek

    2011-09-01

    Full Text Available Greenhouse gas budgets quantified via land-surface eddy covariance (EC flux sites differ significantly from those obtained via inverse modeling. A possible reason for the discrepancy between methods may be our gap in quantitative knowledge of methane (CH4 fluxes. In this study we carried out EC flux measurements during two intensive campaigns in summer 2008 to quantify methane flux from a hydropower reservoir and link its temporal variability to environmental driving forces: water temperature and pressure changes (atmospheric and due to changes in lake level. Methane fluxes were extremely high and highly variable, but consistently showed gas efflux from the lake when the wind was approaching the EC sensors across the open water, as confirmed by floating chamber flux measurements. The average flux was 3.8 ± 0.4 μg C m−2 s−1 (mean ± SE with a median of 1.4 μg C m−2 s−1, which is quite high even compared to tropical reservoirs. Floating chamber fluxes from four selected days confirmed such high fluxes with 7.4 ± 1.3 μg C m−2 s−1. Fluxes increased exponentially with increasing temperatures, but were decreasing exponentially with increasing atmospheric and/or lake level pressure. A multiple regression using lake surface temperatures (0.1 m depth, temperature at depth (10 m deep in front of the dam, atmospheric pressure, and lake level was able to explain 35.4% of the overall variance. This best fit included each variable averaged over a 9-h moving window, plus the respective short-term residuals thereof. We estimate that an annual average of 3% of the particulate organic matter (POM input via the river is sufficient to sustain these large CH4 fluxes. To compensate the global warming potential associated with the CH4 effluxes from this hydropower reservoir a 1.3 to 3.7 times larger terrestrial area with net carbon dioxide uptake is needed if a European-scale compilation of grasslands, croplands and forests is taken as reference. This

  18. Utilization technique on variable speed device

    International Nuclear Information System (INIS)

    1989-12-01

    This reports of workshop on power technology describes using technique on variable speed device, which deals with alternating current situation and prospect of current variable speed device, technical trend and prospect of electronics, reduce expenses by variable speed device, control technique, measurement technology, high voltage variable speed device, recent trend of inverter technology, low voltage and high voltage variable speed device control device, operating variable speed device in cooling fan, FDF application and defect case of variable speed device, cooling pump application of water variable transformer, inverter application and energy effect of ventilation equipment, application of variable speed device and analysis of the result of operation and study for application of variable speed technology.

  19. Selection of entropy-measure parameters for knowledge discovery in heart rate variability data.

    Science.gov (United States)

    Mayer, Christopher C; Bachler, Martin; Hörtenhuber, Matthias; Stocker, Christof; Holzinger, Andreas; Wassertheurer, Siegfried

    2014-01-01

    Heart rate variability is the variation of the time interval between consecutive heartbeats. Entropy is a commonly used tool to describe the regularity of data sets. Entropy functions are defined using multiple parameters, the selection of which is controversial and depends on the intended purpose. This study describes the results of tests conducted to support parameter selection, towards the goal of enabling further biomarker discovery. This study deals with approximate, sample, fuzzy, and fuzzy measure entropies. All data were obtained from PhysioNet, a free-access, on-line archive of physiological signals, and represent various medical conditions. Five tests were defined and conducted to examine the influence of: varying the threshold value r (as multiples of the sample standard deviation σ, or the entropy-maximizing rChon), the data length N, the weighting factors n for fuzzy and fuzzy measure entropies, and the thresholds rF and rL for fuzzy measure entropy. The results were tested for normality using Lilliefors' composite goodness-of-fit test. Consequently, the p-value was calculated with either a two sample t-test or a Wilcoxon rank sum test. The first test shows a cross-over of entropy values with regard to a change of r. Thus, a clear statement that a higher entropy corresponds to a high irregularity is not possible, but is rather an indicator of differences in regularity. N should be at least 200 data points for r = 0.2 σ and should even exceed a length of 1000 for r = rChon. The results for the weighting parameters n for the fuzzy membership function show different behavior when coupled with different r values, therefore the weighting parameters have been chosen independently for the different threshold values. The tests concerning rF and rL showed that there is no optimal choice, but r = rF = rL is reasonable with r = rChon or r = 0.2σ. Some of the tests showed a dependency of the test significance on the data at hand. Nevertheless, as the medical

  20. The WFCAM multiwavelength Variable Star Catalog

    Science.gov (United States)

    Ferreira Lopes, C. E.; Dékány, I.; Catelan, M.; Cross, N. J. G.; Angeloni, R.; Leão, I. C.; De Medeiros, J. R.

    2015-01-01

    Context. Stellar variability in the near-infrared (NIR) remains largely unexplored. The exploitation of public science archives with data-mining methods offers a perspective for a time-domain exploration of the NIR sky. Aims: We perform a comprehensive search for stellar variability using the optical-NIR multiband photometric data in the public Calibration Database of the WFCAM Science Archive (WSA), with the aim of contributing to the general census of variable stars and of extending the current scarce inventory of accurate NIR light curves for a number of variable star classes. Methods: Standard data-mining methods were applied to extract and fine-tune time-series data from the WSA. We introduced new variability indices designed for multiband data with correlated sampling, and applied them for preselecting variable star candidates, i.e., light curves that are dominated by correlated variations, from noise-dominated ones. Preselection criteria were established by robust numerical tests for evaluating the response of variability indices to the colored noise characteristic of the data. We performed a period search using the string-length minimization method on an initial catalog of 6551 variable star candidates preselected by variability indices. Further frequency analysis was performed on positive candidates using three additional methods in combination, in order to cope with aliasing. Results: We find 275 periodic variable stars and an additional 44 objects with suspected variability with uncertain periods or apparently aperiodic variation. Only 44 of these objects had been previously known, including 11 RR Lyrae stars on the outskirts of the globular cluster M 3 (NGC 5272). We provide a preliminary classification of the new variable stars that have well-measured light curves, but the variability types of a large number of objects remain ambiguous. We classify most of the new variables as contact binary stars, but we also find several pulsating stars, among which

  1. Southern Hemisphere Carbon Monoxide Inferannual Variability Observed by Terra/Measurement of Pollution in the Troposphere (MOPITT)

    Science.gov (United States)

    Edwards, D. P.; Petron, G.; Novelli, P. C.; Emmons, L. K.; Gille, J. C.; Drummond, J. R.

    2010-01-01

    Biomass burning is an annual occurrence in the tropical southern hemisphere (SH) and represents a major source of regional pollution. Vegetation fires emit carbon monoxide (CO), which due to its medium lifetime is an excellent tracer of tropospheric transport. CO is also one of the few tropospheric trace gases currently observed from satellite and this provides long-term global measurements. In this paper, we use the 5 year CO data record from the Measurement Of Pollution In The Troposphere (MOPITT) instrument to examine the inter-annual variability of the SH CO loading and show how this relates to climate conditions which determine the intensity of fire sources. The MOPITT observations show an annual austral springtime peak in the SH zonal CO loading each year with dry-season biomass burning emissions in S. America, southern Africa, the Maritime Continent, and northwestern Australia. Although fires in southern Africa and S. America typically produce the greatest amount of CO, the most significant inter-annual variation is due to varying fire activity and emissions from the Maritime Continent and northern Australia. We find that this variation in turn correlates well with the El Nino Southern Oscillation precipitation index. Between 2000 and 2005, emissions were greatest in late 2002 and an inverse modeling of the MOPITT data using the MOZART chemical transport model estimates the southeast Asia regional fire source for the year August 2002 to September 2003 to be 52 Tg CO. Comparison of the MOPITT retrievals and NOAA surface network measurements indicate that the latter do not fully capture the inter-annual variability or the seasonal range of the CO zonal average concentration due to biases associated with atmospheric and geographic sampling.

  2. Quantification of variables that affect energy consumption

    International Nuclear Information System (INIS)

    Warren, C.S.

    1993-01-01

    Facility energy consumption is the summation of a number of contributory factors, caused by equipment that uses energy in response to demands placed by the user and according to its particular design. While energy efficiency improvements usually concentrate on individual parts or systems, overall energy consumption is analyzed by examining the use of specific fuels. Because independent variables effect the consumption of these fuels, accurate comparisons of a facility's energy consumption for time-measured periods must include these effects. In many cases, it is possible to determine and quantify the effects of one or more of the independent variables through a statistically valid regression analysis of the data. The regression model can be linear, or be dependent on other functions such as powers, time lead or lag, or exponential. The most common model is linear, but other dependencies are often encountered. Regression analyses are not difficult to accomplish, and are included as one of the tools in most spreadsheet software. The analyses provide the energy manager with a means to better understand the energy consumption of his/her facility

  3. Low-Frequency Temporal Variability in Mira and Semiregular Variables

    Science.gov (United States)

    Templeton, Matthew R.; Karovska, M.; Waagen, E. O.

    2012-01-01

    We investigate low-frequency variability in a large sample of Mira and semiregular variables with long-term visual light curves from the AAVSO International Database. Our aim is to determine whether we can detect and measure long-timescale variable phenomena in these stars, for example photometric variations that might be associated with supergranular convection. We analyzed the long-term light curves of 522 variable stars of the Mira and SRa, b, c, and d classes. We calculated their low-frequency time-series spectra to characterize rednoise with the power density spectrum index, and then correlate this index with other observable characteristics such as spectral type and primary pulsation period. In our initial analysis of the sample, we see that the semiregular variables have a much broader range of spectral index than the Mira types, with the SRb subtype having the broadest range. Among Mira variables we see that the M- and S-type Miras have similarly wide ranges of index, while the C-types have the narrowest with generally shallower slopes. There is also a trend of steeper slope with larger amplitude, but at a given amplitude, a wide range of slopes are seen. The ultimate goal of the project is to identify stars with strong intrinsic red noise components as possible targets for resolved surface imaging with interferometry.

  4. Measurement of two-phase flow variables in a BWR by analysis of in-core neutron detector noise signals

    International Nuclear Information System (INIS)

    Stekelenburg, A.J.C.; Hagen, T.H.J.J. van der

    1996-01-01

    In this paper, the state of the art of the measurement of two-phase flow variables in a boiling water reactor (BWR) by analysis of in-core neutron detector noise signals is given. It is concluded that the neutronic processes involved in neutron noise are quite well understood, but that little is known about the density fluctuations in two-phase flow which are the main cause of the neutron noise. For this reason, the neutron noise measurements, like the well known two-detector velocity measurements, are still difficult to interpret. By analyzing neutron noise measurements in a natural circulation cooled BWR, it is illustrated that, once a theory on the density fluctuations is developed, two-phase flow can be monitored with a single in-core detector. (author). 70 refs, 4 figs

  5. Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability.

    Science.gov (United States)

    Stergiou, George S; Parati, Gianfranco; Vlachopoulos, Charalambos; Achimastos, Apostolos; Andreadis, Emanouel; Asmar, Roland; Avolio, Alberto; Benetos, Athanase; Bilo, Grzegorz; Boubouchairopoulou, Nadia; Boutouyrie, Pierre; Castiglioni, Paolo; de la Sierra, Alejandro; Dolan, Eamon; Head, Geoffrey; Imai, Yutaka; Kario, Kazuomi; Kollias, Anastasios; Kotsis, Vasilis; Manios, Efstathios; McManus, Richard; Mengden, Thomas; Mihailidou, Anastasia; Myers, Martin; Niiranen, Teemu; Ochoa, Juan Eugenio; Ohkubo, Takayoshi; Omboni, Stefano; Padfield, Paul; Palatini, Paolo; Papaioannou, Theodore; Protogerou, Athanasios; Redon, Josep; Verdecchia, Paolo; Wang, Jiguang; Zanchetti, Alberto; Mancia, Giuseppe; O'Brien, Eoin

    2016-09-01

    Office blood pressure measurement has been the basis for hypertension evaluation for almost a century. However, the evaluation of blood pressure out of the office using ambulatory or self-home monitoring is now strongly recommended for the accurate diagnosis in many, if not all, cases with suspected hypertension. Moreover, there is evidence that the variability of blood pressure might offer prognostic information that is independent of the average blood pressure level. Recently, advancement in technology has provided noninvasive evaluation of central (aortic) blood pressure, which might have attributes that are additive to the conventional brachial blood pressure measurement. This position statement, developed by international experts, deals with key research and practical issues in regard to peripheral blood pressure measurement (office, home, and ambulatory), blood pressure variability, and central blood pressure measurement. The objective is to present current achievements, identify gaps in knowledge and issues concerning clinical application, and present relevant research questions and directions to investigators and manufacturers for future research and development (primary goal).

  6. Cortisol Variability and Self-reports in the Measurement of Work-related Stress

    DEFF Research Database (Denmark)

    Karlson, Björn; Eek, Frida; Hansen, Åse Marie

    2011-01-01

    We examined whether a high cortisol awakening response (CAR) and low cortisol decline over the day (CDD) are related to self-reported work stress and well-being, and whether there are gender differences in these relationships. Three hundred eighty-three working men and women responded to a survey...... measuring job stress factors, mastery at work, symptoms and well-being. Salivary cortisol was sampled at awakening, after 45 min and at 21:00, from which the variables CAR and CDD were defi ned. A high CAR was associated with lower perceived job control and work mastery, and poorer well-being. Low CDD...... men, a similar comparison showed those with low CDD to have poorer scores on job stress factors and symptom load. We conclude that individuals displaying high CAR or low CDD differ from those not displaying these cortisol profi les in self-report of work stress and well-being, and that gender...

  7. LACK OF AGREEMENT BETWEEN GAS EXCHANGE VARIABLES MEASURED BY TWO METABOLIC SYSTEMS

    Directory of Open Access Journals (Sweden)

    DjordjeG. Jakovljevic

    2008-03-01

    Full Text Available The purpose of this study was to assess the agreement and consistency between gas exchange variables measured by two online metabolic systems during an incremental exercise test. After obtaining local ethics approval and informed consent, 15 healthy subjects performed an incremental exercise test to volitional fatigue using the Bruce protocol. The Innocor (Innovision, Denmark and CardiO2 (Medical Graphics, USA systems were placed in series, with the Innocor mouthpiece attached to the pneumotach of the CardiO2. Metabolic data were analysed during the last 30 seconds of each stage and at peak exercise. There were non- significant differences (p > 0.05 between the two systems in estimation of oxygen consumption (VO2 and in minute ventilation (VE. Mean Cronbach's alpha for VO2 and VE were 0.88 and 0.92. The Bland-Altman analysis revealed that limits of agreement were -0.52 to 0.55 l.min-1 for VO2, and -8.74 to 10.66 l.min-1 for VE. Carbon dioxide production (VCO2 and consequently respiratory exchange ratio (RER measured by the Innocor were significantly lower (p < 0.05 through all stages. The CardiO2 measured fraction of expired carbon dioxide (FeCO2 significantly higher (p < 0.05. The limits of agreement for VO2 and VE are wide and unacceptable in cardio-pulmonary exercise testing. The Innocor reported VCO2 systematically lower. Therefore the Innocor and CardiO2 metabolic systems cannot be used interchangeably without affecting the diagnosis of an individual patient. Results from the present study support previous suggestion that considerable care is needed when comparing metabolic data obtained from different automated metabolic systems.

  8. A SEARCH FOR L/T TRANSITION DWARFS WITH Pan-STARRS1 AND WISE: DISCOVERY OF SEVEN NEARBY OBJECTS INCLUDING TWO CANDIDATE SPECTROSCOPIC VARIABLES

    Energy Technology Data Exchange (ETDEWEB)

    Best, William M. J.; Liu, Michael C.; Magnier, Eugene A.; Aller, Kimberly M.; Burgett, W. S.; Chambers, K. C.; Hodapp, K. W.; Kaiser, N.; Kudritzki, R.-P.; Morgan, J. S.; Tonry, J. L.; Wainscoat, R. J. [Institute for Astronomy, University of Hawaii at Manoa, Honolulu, HI 96822 (United States); Deacon, Niall R. [Max Planck Institute for Astronomy, Koenigstuhl 17, D-69117 Heidelberg (Germany); Dupuy, Trent J. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Redstone, Joshua [Facebook, 335 Madison Ave, New York, NY 10017-4677 (United States); Price, P. A., E-mail: wbest@ifa.hawaii.edu [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 08544 (United States)

    2013-11-10

    We present initial results from a wide-field (30,000 deg{sup 2}) search for L/T transition brown dwarfs within 25 pc using the Pan-STARRS1 and Wide-field Infrared Survey Explorer (WISE) surveys. Previous large-area searches have been incomplete for L/T transition dwarfs, because these objects are faint in optical bands and have near-infrared (near-IR) colors that are difficult to distinguish from background stars. To overcome these obstacles, we have cross-matched the Pan-STARRS1 (optical) and WISE (mid-IR) catalogs to produce a unique multi-wavelength database for finding ultracool dwarfs. As part of our initial discoveries, we have identified seven brown dwarfs in the L/T transition within 9-15 pc of the Sun. The L9.5 dwarf PSO J140.2308+45.6487 and the T1.5 dwarf PSO J307.6784+07.8263 (both independently discovered by Mace et al.) show possible spectroscopic variability at the Y and J bands. Two more objects in our sample show evidence of photometric J-band variability, and two others are candidate unresolved binaries based on their spectra. We expect our full search to yield a well-defined, volume-limited sample of L/T transition dwarfs that will include many new targets for study of this complex regime. PSO J307.6784+07.8263 in particular may be an excellent candidate for in-depth study of variability, given its brightness (J = 14.2 mag) and proximity (11 pc)

  9. ASSESSMENT OF THE CHANGES IN BLOOD PRESSURE CIRCADIAN PROFILE AND VARIABILITY IN PATIENTS WITH CHRONIC HEART FAILURE AND ARTERIAL HYPERTENSION DURING COMBINED THERAPY INCLUDING IVABRADINE

    Directory of Open Access Journals (Sweden)

    M. V. Surovtseva

    2012-01-01

    Full Text Available Aim. To assess the changes in blood pressure (BP circadian profile and variability in patients with chronic heart failure (CHF of ischemic etiology and arterial hypertension (HT due to the complex therapy including ivabradine. Material and methods. Patients (n=90 with CHF class II–III NYHA associated with stable angina II-III class and HT were examined. The patients were randomized into 3 groups depending on received drugs: perindopril and ivabradine - group 1; perindopril, bisoprolol and ivabradine - group 2; perindopril and bisoprolol - group 3. The duration of therapy was 6 months. Ambulatory BP monitoring (ABPM was assessed at baseline and after treatment. Results. More significant reduction in average 24-hours systolic BP was found in groups 1 and 2 compared to group 3 (Δ%: -19.4±0,4; -21.1±0.4 and -11.8±0.6, respectively as well as diastolic BP (Δ%: -10.6±0.6; -12.9±0.4 and -4,3±0.3, respectively and other ABPM indicators. Improvement of BP circadian rhythm was found due to increase in the number of «Dipper» patients (p=0.016. More significant reduction in average daily and night systolic and diastolic BP (p=0.001, as well as daily and night BP variability (p=0.001 was also found in patients of group 2 compared to these of group 1. Conclusion. Moderate antihypertensive effect (in respect of both diastolic and systolic BP was shown when ivabradine was included into the complex therapy of patients with ischemic CHF and HT. The effect was more pronounced when ivabradine was combined with perindopril and bisoprolol. This was accompanied by reduction in high BP daily variability and improvement of the BP circadian rhythm. 

  10. ASSESSMENT OF THE CHANGES IN BLOOD PRESSURE CIRCADIAN PROFILE AND VARIABILITY IN PATIENTS WITH CHRONIC HEART FAILURE AND ARTERIAL HYPERTENSION DURING COMBINED THERAPY INCLUDING IVABRADINE

    Directory of Open Access Journals (Sweden)

    M. V. Surovtseva

    2015-12-01

    Full Text Available Aim. To assess the changes in blood pressure (BP circadian profile and variability in patients with chronic heart failure (CHF of ischemic etiology and arterial hypertension (HT due to the complex therapy including ivabradine. Material and methods. Patients (n=90 with CHF class II–III NYHA associated with stable angina II-III class and HT were examined. The patients were randomized into 3 groups depending on received drugs: perindopril and ivabradine - group 1; perindopril, bisoprolol and ivabradine - group 2; perindopril and bisoprolol - group 3. The duration of therapy was 6 months. Ambulatory BP monitoring (ABPM was assessed at baseline and after treatment. Results. More significant reduction in average 24-hours systolic BP was found in groups 1 and 2 compared to group 3 (Δ%: -19.4±0,4; -21.1±0.4 and -11.8±0.6, respectively as well as diastolic BP (Δ%: -10.6±0.6; -12.9±0.4 and -4,3±0.3, respectively and other ABPM indicators. Improvement of BP circadian rhythm was found due to increase in the number of «Dipper» patients (p=0.016. More significant reduction in average daily and night systolic and diastolic BP (p=0.001, as well as daily and night BP variability (p=0.001 was also found in patients of group 2 compared to these of group 1. Conclusion. Moderate antihypertensive effect (in respect of both diastolic and systolic BP was shown when ivabradine was included into the complex therapy of patients with ischemic CHF and HT. The effect was more pronounced when ivabradine was combined with perindopril and bisoprolol. This was accompanied by reduction in high BP daily variability and improvement of the BP circadian rhythm. 

  11. Variability in reaction time performance of younger and older adults.

    Science.gov (United States)

    Hultsch, David F; MacDonald, Stuart W S; Dixon, Roger A

    2002-03-01

    Age differences in three basic types of variability were examined: variability between persons (diversity), variability within persons across tasks (dispersion), and variability within persons across time (inconsistency). Measures of variability were based on latency performance from four measures of reaction time (RT) performed by a total of 99 younger adults (ages 17--36 years) and 763 older adults (ages 54--94 years). Results indicated that all three types of variability were greater in older compared with younger participants even when group differences in speed were statistically controlled. Quantile-quantile plots showed age and task differences in the shape of the inconsistency distributions. Measures of within-person variability (dispersion and inconsistency) were positively correlated. Individual differences in RT inconsistency correlated negatively with level of performance on measures of perceptual speed, working memory, episodic memory, and crystallized abilities. Partial set correlation analyses indicated that inconsistency predicted cognitive performance independent of level of performance. The results indicate that variability of performance is an important indicator of cognitive functioning and aging.

  12. Entanglement enhancement through multirail noise reduction for continuous-variable measurement-based quantum-information processing

    Science.gov (United States)

    Su, Yung-Chao; Wu, Shin-Tza

    2017-09-01

    We study theoretically the teleportation of a controlled-phase (cz) gate through measurement-based quantum-information processing for continuous-variable systems. We examine the degree of entanglement in the output modes of the teleported cz-gate for two classes of resource states: the canonical cluster states that are constructed via direct implementations of two-mode squeezing operations and the linear-optical version of cluster states which are built from linear-optical networks of beam splitters and phase shifters. In order to reduce the excess noise arising from finite-squeezed resource states, teleportation through resource states with different multirail designs will be considered and the enhancement of entanglement in the teleported cz gates will be analyzed. For multirail cluster with an arbitrary number of rails, we obtain analytical expressions for the entanglement in the output modes and analyze in detail the results for both classes of resource states. At the same time, we also show that for uniformly squeezed clusters the multirail noise reduction can be optimized when the excess noise is allocated uniformly to the rails. To facilitate the analysis, we develop a trick with manipulations of quadrature operators that can reveal rather efficiently the measurement sequence and corrective operations needed for the measurement-based gate teleportation, which will also be explained in detail.

  13. Spatial variability of carbon dioxide in the urban canopy layer and implications for flux measurements

    Science.gov (United States)

    Crawford, B.; Christen, A.

    2014-12-01

    This contribution reports CO2 mixing ratios measured in the urban canopy layer (UCL) of a residential neighborhood in Vancouver, BC, Canada and discusses the relevance of UCL CO2 temporal and spatial variability to local-scale eddy covariance (EC) fluxes measured above the UCL. Measurements were conducted from a mobile vehicle-mounted platform over a continuous, 26-h period in the longterm turbulent flux source area of an urban EC tower. Daytime mixing ratios were highest along arterial roads and largely a function of proximity to vehicle traffic CO2 sources. At night, there was a distinct negative correlation between potential air temperature and CO2 mixing ratios. The spatial distribution of CO2 was controlled by topography and micro-scale advective processes (i.e. cold-air pooling). Mobile CO2 measurements were then used to calculate CO2 storage changes (FS) in the UCL volume and compared to single-layer FS estimates calculated from the EC system. In total, five variations of FS were calculated. On average, the choice of FS calculation method affected net measured hourly emissions (FC) by 5.2%. Analysis of FS using a four-year dataset measured at the EC tower show FS was 2.8% of hourly FC for this site on average. At this urban EC location, FS was relatively minor compared to FC and calculation of FS using a single-layer method was adequate, though FS still represents a potentially large uncertainty during individual hours.

  14. Use of count-based image reconstruction to evaluate the variability and repeatability of measured standardised uptake values.

    Directory of Open Access Journals (Sweden)

    Tomohiro Kaneta

    Full Text Available Standardized uptake values (SUVs are the most widely used quantitative imaging biomarkers in PET. It is important to evaluate the variability and repeatability of measured SUVs. Phantom studies seem to be essential for this purpose; however, repetitive phantom scanning is not recommended due to the decay of radioactivity. In this study, we performed count-based image reconstruction to avoid the influence of decay using two different PET/CT scanners. By adjusting the ratio of 18F-fluorodeoxyglucose solution to tap water, a NEMA IEC body phantom was set for SUVs of 4.0 inside six hot spheres. The PET data were obtained using two scanners (Aquiduo and Celesteion; Toshiba Medical Systems, Tochigi, Japan. We set the start time for image reconstruction when the total radioactivity in the phantom was 2.53 kBq/cc, and employed the counts of the first 2-min acquisition as the standard. To maintain the number of counts for each image, we set the acquisition time for image reconstruction depending on the decay of radioactivity. We obtained 50 images, and calculated the SUVmax and SUVpeak of all six spheres in each image. The average values of the SUVmax were used to calculate the recovery coefficients to compare those measured by the two different scanners. Bland-Altman analyses of the SUVs measured by the two scanners were also performed. The measured SUVs using the two scanners exhibited a 10-30% difference, and the standard deviation (SD of the measured SUVs was between 0.1-0.2. The Celesteion always exhibited higher values than the Aquiduo. The smaller sphere exhibited a larger SD, and the SUVpeak had a smaller SD than the SUVmax. The Bland-Altman analyses showed poor agreement between the SUVs measured by the two scanners. The recovery coefficient curves obtained from the two scanners were considerably different. The Celesteion exhibited higher recovery coefficients than the Aquiduo, especially at approximately 20-mm-diameter. Additionally, the curves

  15. A DESCRIPTION OF QUASAR VARIABILITY MEASURED USING REPEATED SDSS AND POSS IMAGING

    International Nuclear Information System (INIS)

    MacLeod, Chelsea L.; Ivezić, Željko; Becker, Andrew C.; Anderson, Scott F.; Sesar, Branimir; De Vries, Wim; Kochanek, Christopher S.; Kelly, Brandon C.; Lupton, Robert H.; Hall, Patrick B.; Richards, Gordon T.; Schneider, Donald P.

    2012-01-01

    We provide a quantitative description and statistical interpretation of the optical continuum variability of quasars. The Sloan Digital Sky Survey (SDSS) has obtained repeated imaging in five UV-to-IR photometric bands for 33,881 spectroscopically confirmed quasars. About 10,000 quasars have an average of 60 observations in each band obtained over a decade along Stripe 82 (S82), whereas the remaining ∼25,000 have 2-3 observations due to scan overlaps. The observed time lags span the range from a day to almost 10 years, and constrain quasar variability at rest-frame time lags of up to 4 years, and at rest-frame wavelengths from 1000 Å to 6000 Å. We publicly release a user-friendly catalog of quasars from the SDSS Data Release 7 that have been observed at least twice in SDSS or once in both SDSS and the Palomar Observatory Sky Survey, and we use it to analyze the ensemble properties of quasar variability. Based on a damped random walk (DRW) model defined by a characteristic timescale and an asymptotic variability amplitude that scale with the luminosity, black hole mass, and rest wavelength for individual quasars calibrated in S82, we can fully explain the ensemble variability statistics of the non-S82 quasars such as the exponential distribution of large magnitude changes. All available data are consistent with the DRW model as a viable description of the optical continuum variability of quasars on timescales of ∼5-2000 days in the rest frame. We use these models to predict the incidence of quasar contamination in transient surveys such as those from the Palomar Transient Factory and Large Synoptic Survey Telescope.

  16. Temporally variable macroinvertebrate-stone relationships in streams

    DEFF Research Database (Denmark)

    Jacobsen, D.

    2005-01-01

    of fauna parameter and stone variable from different sampling dates (n=9-11) were rarely correlated to any of the measures of stream stability, this study has demonstrated high temporal variability in fauna-stone relationships (CV's of regression slopes). Consequently, temporally un-replicated studies......Stones were used to sample macroinvertebrates and characterise microhabitats at monthly or bimonthly intervals in six Ecuadorian streams covering a gradient in four different stability measures and other stream characteristics. The physical variables current velocity, water depth, horizontal...... of families vs. individuals) were related to the physical characteristics of individual stone habitats. My second objective was to quantify temporal variability in fauna-stone relationships and to analyse if such variability was related to overall stability of stream reaches. Partial Least Squares (PLS...

  17. Recent Variability Observations of Solar System Giant Planets: Fresh Context for Understanding Exoplanet and Brown Dwarf Weather

    Science.gov (United States)

    Marley, Mark Scott

    2016-01-01

    Over the past several years a number of high cadence photometric observations of solar system giant planets have been acquired by various platforms. Such observations are of interest as they provide points of comparison to the already expansive set of brown dwarf variability observations and the small, but growing, set of exoplanet variability observations. By measuring how rapidly the integrated light from solar system giant planets can evolve, variability observations of substellar objects that are unlikely to ever be resolved can be placed in a fuller context. Examples of brown dwarf variability observations include extensive work from the ground (e.g., Radigen et al. 2014), Spitzer (e.g., Metchev et al. 2015), Kepler (Gizis et al. 2015), and HST (Yang et al. 2015).Variability has been measured on the planetary mass companion to the brown dwarf 2MASS 1207b (Zhou et al. 2016) and further searches are planned in thermal emission for the known directly imaged planets with ground based telescopes (Apai et al. 2016) and in reflected light with future space based telescopes. Recent solar system variability observations include Kepler monitoring of Neptune (Simon et al. 2016) and Uranus, Spitzer observations of Neptune (Stauffer et al. 2016), and Cassini observations of Jupiter (West et al. in prep). The Cassini observations are of particular interest as they measured the variability of Jupiter at a phase angle of approximately 60 deg, comparable to the viewing geometry expected for space based direct imaging of cool extrasolar Jupiters in reflected light. These solar system analog observations capture many of the characteristics seen in brown dwarf variability, including large amplitudes and rapid light curve evolution on timescales as short as a few rotation periods. Simon et al. (2016) attribute such variations at Neptune to a combination of large scale, stable cloud structures along with smaller, more rapidly varying, cloud patches. The observed brown dwarf and

  18. Sensitivity of adaptive enrichment trial designs to accrual rates, time to outcome measurement, and prognostic variables

    Directory of Open Access Journals (Sweden)

    Tianchen Qian

    2017-12-01

    Full Text Available Adaptive enrichment designs involve rules for restricting enrollment to a subset of the population during the course of an ongoing trial. This can be used to target those who benefit from the experimental treatment. Trial characteristics such as the accrual rate and the prognostic value of baseline variables are typically unknown when a trial is being planned; these values are typically assumed based on information available before the trial starts. Because of the added complexity in adaptive enrichment designs compared to standard designs, it may be of special concern how sensitive the trial performance is to deviations from assumptions. Through simulation studies, we evaluate the sensitivity of Type I error, power, expected sample size, and trial duration to different design characteristics. Our simulation distributions mimic features of data from the Alzheimer's Disease Neuroimaging Initiative cohort study, and involve two subpopulations based on a genetic marker. We investigate the impact of the following design characteristics: the accrual rate, the time from enrollment to measurement of a short-term outcome and the primary outcome, and the prognostic value of baseline variables and short-term outcomes. To leverage prognostic information in baseline variables and short-term outcomes, we use a semiparametric, locally efficient estimator, and investigate its strengths and limitations compared to standard estimators. We apply information-based monitoring, and evaluate how accurately information can be estimated in an ongoing trial.

  19. Variability in ACL tunnel placement: observational clinical study of surgeon ACL tunnel variability.

    Science.gov (United States)

    Wolf, Brian R; Ramme, Austin J; Wright, Rick W; Brophy, Robert H; McCarty, Eric C; Vidal, Armando R; Parker, Richard D; Andrish, Jack T; Amendola, Annunziato

    2013-06-01

    Multicenter and multisurgeon cohort studies on anterior cruciate ligament (ACL) reconstruction are becoming more common. Minimal information exists on intersurgeon and intrasurgeon variability in ACL tunnel placement. Purpose/ The purpose of this study was to analyze intersurgeon and intrasurgeon variability in ACL tunnel placement in a series of The Multicenter Orthopaedic Outcomes Network (MOON) ACL reconstruction patients and in a clinical cohort of ACL reconstruction patients. The hypothesis was that there would be minimal variability between surgeons in ACL tunnel placement. Cross-sectional study; Level of evidence, 3. Seventy-eight patients who underwent ACL reconstruction by 8 surgeons had postoperative imaging with computed tomography, and ACL tunnel location and angulation were analyzed using 3-dimensional surface processing and measurement. Intersurgeon and intrasurgeon variability in ACL tunnel placement was analyzed. For intersurgeon variability, the range in mean ACL femoral tunnel depth between surgeons was 22%. For femoral tunnel height, there was a 19% range. Tibial tunnel location from anterior to posterior on the plateau had a 16% range in mean results. There was only a small range of 4% for mean tibial tunnel location from the medial to lateral dimension. For intrasurgeon variability, femoral tunnel depth demonstrated the largest ranges, and tibial tunnel location from medial to lateral on the plateau demonstrated the least variability. Overall, surgeons were relatively consistent within their own cases. Using applied measurement criteria, 85% of femoral tunnels and 90% of tibial tunnels fell within applied literature-based guidelines. Ninety-one percent of the axes of the femoral tunnels fell within the boundaries of the femoral footprint. The data demonstrate that surgeons performing ACL reconstructions are relatively consistent between each other. There is, however, variability of average tunnel placement up to 22% of mean condylar depth

  20. Constructing Proxy Variables to Measure Adult Learners' Time Management Strategies in LMS

    Science.gov (United States)

    Jo, Il-Hyun; Kim, Dongho; Yoon, Meehyun

    2015-01-01

    This study describes the process of constructing proxy variables from recorded log data within a Learning Management System (LMS), which represents adult learners' time management strategies in an online course. Based on previous research, three variables of total login time, login frequency, and regularity of login interval were selected as…

  1. Machine learning search for variable stars

    Science.gov (United States)

    Pashchenko, Ilya N.; Sokolovsky, Kirill V.; Gavras, Panagiotis

    2018-04-01

    Photometric variability detection is often considered as a hypothesis testing problem: an object is variable if the null hypothesis that its brightness is constant can be ruled out given the measurements and their uncertainties. The practical applicability of this approach is limited by uncorrected systematic errors. We propose a new variability detection technique sensitive to a wide range of variability types while being robust to outliers and underestimated measurement uncertainties. We consider variability detection as a classification problem that can be approached with machine learning. Logistic Regression (LR), Support Vector Machines (SVM), k Nearest Neighbours (kNN), Neural Nets (NN), Random Forests (RF), and Stochastic Gradient Boosting classifier (SGB) are applied to 18 features (variability indices) quantifying scatter and/or correlation between points in a light curve. We use a subset of Optical Gravitational Lensing Experiment phase two (OGLE-II) Large Magellanic Cloud (LMC) photometry (30 265 light curves) that was searched for variability using traditional methods (168 known variable objects) as the training set and then apply the NN to a new test set of 31 798 OGLE-II LMC light curves. Among 205 candidates selected in the test set, 178 are real variables, while 13 low-amplitude variables are new discoveries. The machine learning classifiers considered are found to be more efficient (select more variables and fewer false candidates) compared to traditional techniques using individual variability indices or their linear combination. The NN, SGB, SVM, and RF show a higher efficiency compared to LR and kNN.

  2. Footprint radius of a cosmic-ray neutron probe for measuring soil-water content and its spatiotemporal variability in an alpine meadow ecosystem

    Science.gov (United States)

    Zhu, Xuchao; Cao, Ruixue; Shao, Mingan; Liang, Yin

    2018-03-01

    Cosmic-ray neutron probes (CRNPs) have footprint radii for measuring soil-water content (SWC). The theoretical radius is much larger at high altitude, such as the northern Tibetan Plateau, than the radius at sea level. The most probable practical radius of CRNPs for the northern Tibetan Plateau, however, is not known due to the lack of SWC data in this hostile environment. We calculated the theoretical footprint of the CRNP based on a recent simulation and analyzed the practical radius of a CRNP for the northern Tibetan Plateau by measuring SWC at 113 sampling locations on 21 measuring occasions to a depth of 30 cm in a 33.5 ha plot in an alpine meadow at 4600 m a.s.l. The temporal variability and spatial heterogeneity of SWC within the footprint were then analyzed. The theoretical footprint radius was between 360 and 420 m after accounting for the influences of air humidity, soil moisture, vegetation and air pressure. A comparison of SWCs measured by the CRNP and a neutron probe from access tubes in circles with different radii conservatively indicated that the most probable experimental footprint radius was >200 m. SWC within the CRNP footprint was moderately variable over both time and space, but the temporal variability was higher. Spatial heterogeneity was weak, but should be considered in future CRNP calibrations. This study provided theoretical and practical bases for the application and promotion of CRNPs in alpine meadows on the Tibetan Plateau.

  3. Infiltration and Runoff Measurements on Steep Burned Hillslopes Using a Rainfall Simulator with Variable Rain Intensities

    Science.gov (United States)

    Kinner, David A.; Moody, John A.

    2008-01-01

    Multiple rainfall intensities were used in rainfall-simulation experiments designed to investigate the infiltration and runoff from 1-square-meter plots on burned hillslopes covered by an ash layer of varying thickness. The 1-square-meter plots were on north- and south-facing hillslopes in an area burned by the Overland fire northwest of Boulder near Jamestown on the Front Range of Colorado. A single-nozzle, wide-angle, multi-intensity rain simulator was developed to investigate the infiltration and runoff on steep (30- to 40-percent gradient) burned hillslopes covered with ash. The simulated rainfall was evaluated for spatial variability, drop size, and kinetic energy. Fourteen rainfall simulations, at three intensities (about 20 millimeters per hour [mm/h], 35 mm/h, and 50 mm/h), were conducted on four plots. Measurements during and after the simulations included runoff, rainfall, suspended-sediment concentrations, surface ash layer thickness, soil moisture, soil grain size, soil lost on ignition, and plot topography. Runoff discharge reached a steady state within 7 to 26 minutes. Steady infiltration rates with the 50-mm/h application rainfall intensity approached 20?35 mm/h. If these rates are projected to rainfall application intensities used in many studies of burned area runoff production (about 80 mm/h), the steady discharge rates are on the lower end of measurements from other studies. Experiments using multiple rainfall intensities (three) suggest that runoff begins at rainfall intensities around 20 mm/h at the 1-square-meter scale, an observation consistent with a 10-mm/h rainfall intensity threshold needed for runoff initiation that has been reported in the literature.

  4. Periorbital biometric measurements using ImageJ software: Standardisation of technique and assessment of intra- and interobserver variability

    Directory of Open Access Journals (Sweden)

    R Rajyalakshmi

    2017-01-01

    Full Text Available Purpose: To assess the reliability and repeatability of periorbital biometric measurements using ImageJ software and to assess if the horizontal visible iris diameter (HVID serves as a reliable scale for facial measurements. Methods: This study was a prospective, single-blind, comparative study. Two clinicians performed 12 periorbital measurements on 100 standardised face photographs. Each individual’s HVID was determined by Orbscan IIz and used as a scale for measurements using ImageJ software. All measurements were repeated using the ‘average’ HVID of the study population as a measurement scale. Intraclass correlation coefficient (ICC and Pearson product-moment coefficient were used as statistical tests to analyse the data. Results: The range of ICC for intra- and interobserver variability was 0.79–0.99 and 0.86–0.99, respectively. Test-retest reliability ranged from 0.66–1.0 to 0.77–0.98, respectively. When average HVID of the study population was used as scale, ICC ranged from 0.83 to 0.99, and the test-retest reliability ranged from 0.83 to 0.96 and the measurements correlated well with recordings done with individual Orbscan HVID measurements. Conclusion: Periorbital biometric measurements using ImageJ software are reproducible and repeatable. Average HVID of the population as measured by Orbscan is a reliable scale for facial measurements.

  5. Understanding Variability in Beach Slope to Improve Forecasts of Storm-induced Water Levels

    Science.gov (United States)

    Doran, K. S.; Stockdon, H. F.; Long, J.

    2014-12-01

    The National Assessment of Hurricane-Induced Coastal Erosion Hazards combines measurements of beach morphology with storm hydrodynamics to produce forecasts of coastal change during storms for the Gulf of Mexico and Atlantic coastlines of the United States. Wave-induced water levels are estimated using modeled offshore wave height and period and measured beach slope (from dune toe to shoreline) through the empirical parameterization of Stockdon et al. (2006). Spatial and temporal variability in beach slope leads to corresponding variability in predicted wave setup and swash. Seasonal and storm-induced changes in beach slope can lead to differences on the order of a meter in wave runup elevation, making accurate specification of this parameter essential to skillful forecasts of coastal change. Spatial variation in beach slope is accounted for through alongshore averaging, but temporal variability in beach slope is not included in the final computation of the likelihood of coastal change. Additionally, input morphology may be years old and potentially very different than the conditions present during forecast storm. In order to improve our forecasts of hurricane-induced coastal erosion hazards, the temporal variability of beach slope must be included in the final uncertainty of modeled wave-induced water levels. Frequently collected field measurements of lidar-based beach morphology are examined for study sites in Duck, North Carolina, Treasure Island, Florida, Assateague Island, Virginia, and Dauphin Island, Alabama, with some records extending over a period of 15 years. Understanding the variability of slopes at these sites will help provide estimates of associated water level uncertainty which can then be applied to other areas where lidar observations are infrequent, and improve the overall skill of future forecasts of storm-induced coastal change. Stockdon, H. F., Holman, R. A., Howd, P. A., and Sallenger Jr, A. H. (2006). Empirical parameterization of setup

  6. Development of a pressure based vortex-shedding meter: measuring unsteady mass-flow in variable density gases

    International Nuclear Information System (INIS)

    Ford, C L; Winroth, M; Alfredsson, P H

    2016-01-01

    An entirely pressure-based vortex-shedding meter has been designed for use in practical time-dependent flows. The meter is capable of measuring mass-flow rate in variable density gases in spite of the fact that fluid temperature is not directly measured. Unlike other vortex meters, a pressure based meter is incredibly robust and may be used in industrial type flows; an environment wholly unsuitable for hot-wires for example. The meter has been tested in a number of static and dynamic flow cases, across a range of mass-flow rates and pressures. The accuracy of the meter is typically better than about 3% in a static flow and resolves the fluctuating mass-flow with an accuracy that is better than or equivalent to a hot-wire method. (paper)

  7. Inter annual variability of the global carbon cycle (1992-2005) inferred by inversion of atmospheric CO2 and δ13CO2 measurements

    International Nuclear Information System (INIS)

    Rayner, P.J.; Pickett-Heaps, C.; Law, R.M.; Allison, C.E.; Francey, R.J.; Trudinger, C.M.

    2008-01-01

    We present estimates of the surface sources and sinks of CO 2 for 1992 - 2005 deduced from atmospheric inversions. We use atmospheric CO 2 records from 67 sites and 10 δ 13 CO 2 records. We use two atmospheric models to increase the robustness of the results. The results suggest that inter annual variability is dominated by the tropical land. Statistically significant variability in the tropical Pacific supports recent ocean modeling studies in that region. The northern land also shows significant variability. In particular, there is a large positive anomaly in 2003 in north Asia, which we associate with anomalous biomass burning. Results using δ 13 CO 2 and CO 2 are statistically consistent with those using only CO 2 , suggesting that it is valid to use both types of data together. An objective analysis of residuals suggests that our treatment of uncertainties in CO 2 is conservative, while those for δ 13 CO 2 are optimistic, highlighting problems in our simple isotope model. Finally, δ 13 CO 2 measurements offer a good constraint to nearby land regions, suggesting an ongoing value in these measurements for studies of inter annual variability. (authors)

  8. Temporal variability of exchange between groundwater and surface water based on high-frequency direct measurements of seepage at the sediment-water interface

    Science.gov (United States)

    Rosenberry, Donald O.; Sheibley, Rich W.; Cox, Stephen E.; Simonds, Frederic W.; Naftz, David L.

    2013-01-01

    Seepage at the sediment-water interface in several lakes, a large river, and an estuary exhibits substantial temporal variability when measured with temporal resolution of 1 min or less. Already substantial seepage rates changed by 7% and 16% in response to relatively small rain events at two lakes in the northeastern USA, but did not change in response to two larger rain events at a lake in Minnesota. However, seepage at that same Minnesota lake changed by 10% each day in response to withdrawals from evapotranspiration. Seepage increased by more than an order of magnitude when a seiche occurred in the Great Salt Lake, Utah. Near the head of a fjord in Puget Sound, Washington, seepage in the intertidal zone varied greatly from −115 to +217 cm d−1 in response to advancing and retreating tides when the time-averaged seepage was upward at +43 cm d−1. At all locations, seepage variability increased by one to several orders of magnitude in response to wind and associated waves. Net seepage remained unchanged by wind unless wind also induced a lake seiche. These examples from sites distributed across a broad geographic region indicate that temporal variability in seepage in response to common hydrological events is much larger than previously realized. At most locations, seepage responded within minutes to changes in surface-water stage and within minutes to hours to groundwater recharge associated with rainfall. Likely implications of this dynamism include effects on water residence time, geochemical transformations, and ecological conditions at and near the sediment-water interface.

  9. Aerosol variability over the Mediterranean basin from 2005-2012 POLDER-3/PARASOL and AERONET/PHOTONS measurements

    Science.gov (United States)

    Chiapello, Isabelle; Ducos, Fabrice; Dulac, François; Léon, Jean-François; Mallet, Marc; Tanré, Didier; Goloub, Philippe

    2013-04-01

    POLDER-3 (Polarization and Directionnality of the Earth's Reflectances) has been launched on board the PARASOL microsatellite in December 2004. Although the PARASOL orbit has been lowered twice (in September 2009 and in November 2011) compared to the other platforms of the A-Train constellation, POLDER observations continue, providing now more than seven years of innovative retrievals of aerosol properties from space. In this study we focus on analyzing POLDER-3 capabilities to derive both aerosol loads (Total Aerosol Optical Thickness) and size properties (fine and coarse spherical/non-spherical Aerosol Optical Thickness, Angström coefficients) over oceanic surfaces. This analysis, as part of the ChArMEx (the Chemistry-Aerosol Mediterranean Experiment) program, focus on the Mediterranean basin, a region under the influence of a complex mixture of aerosols from different sources. Especially we aim to investigate the respective contributions of (i) pollution aerosols (emitted by industry and urban environments of some European regions or megacities surrounding the basin), (ii) carbonaceous particles (from biomass burning events), (iii) mineral dust exported from arid and semi-arid regions of North Africa. In a first step, our study consists in an analysis of aerosol variability retrieved from AERONET/PHOTONS photometer records from selected sites located in Western part of the Mediterranean basin (i.e., Soust-East of France, Spain, Corsica/Sardinia), as well as central part (i.e., Italia and Lampedusa), and Eastern part (i.e.,Greece and Turkey). These measurements provide a unique characterization of both aerosol load (aerosol optical depth) and properties (size distribution and absorption though single scattering albedo) and their temporal variability over each part of the Mediterranean basin. The second step focus on a regional validation of the PARASOL monthly aerosol products by comparison with these equivalent and selected ground-based AERONET

  10. Physical attraction to reliable, low variability nervous systems: Reaction time variability predicts attractiveness.

    Science.gov (United States)

    Butler, Emily E; Saville, Christopher W N; Ward, Robert; Ramsey, Richard

    2017-01-01

    The human face cues a range of important fitness information, which guides mate selection towards desirable others. Given humans' high investment in the central nervous system (CNS), cues to CNS function should be especially important in social selection. We tested if facial attractiveness preferences are sensitive to the reliability of human nervous system function. Several decades of research suggest an operational measure for CNS reliability is reaction time variability, which is measured by standard deviation of reaction times across trials. Across two experiments, we show that low reaction time variability is associated with facial attractiveness. Moreover, variability in performance made a unique contribution to attractiveness judgements above and beyond both physical health and sex-typicality judgements, which have previously been associated with perceptions of attractiveness. In a third experiment, we empirically estimated the distribution of attractiveness preferences expected by chance and show that the size and direction of our results in Experiments 1 and 2 are statistically unlikely without reference to reaction time variability. We conclude that an operating characteristic of the human nervous system, reliability of information processing, is signalled to others through facial appearance. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Test-retest reliability of trunk motor variability measured by large-array surface electromyography.

    Science.gov (United States)

    Abboud, Jacques; Nougarou, François; Loranger, Michel; Descarreaux, Martin

    2015-01-01

    The objective of this study was to evaluate the test-retest reliability of the trunk muscle activity distribution in asymptomatic participants during muscle fatigue using large-array surface electromyography (EMG). Trunk muscle activity distribution was evaluated twice, with 3 to 4 days between them, in 27 asymptomatic volunteers using large-array surface EMG. Motor variability, assessed with 2 different variables (the centroid coordinates of the root mean square map and the dispersion variable), was evaluated during a low back muscle fatigue task. Test-retest reliability of muscle activity distribution was obtained using Pearson correlation coefficients. A shift in the distribution of EMG amplitude toward the lateral-caudal region of the lumbar erector spinae induced by muscle fatigue was observed. Moderate to very strong correlations were found between both sessions in the last 3 phases of the fatigue task for both motor variability variables, whereas weak to moderate correlations were found in the first phases of the fatigue task only for the dispersion variable. These findings show that, in asymptomatic participants, patterns of EMG activity are less reliable in initial stages of muscle fatigue, whereas later stages are characterized by highly reliable patterns of EMG activity. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  12. Organizational variables on nurses' job performance in Turkey: nursing assessments.

    Science.gov (United States)

    Top, Mehmet

    2013-01-01

    The purpose of this study was to describe the influence of organizational variables on hospital staff nurses' job performance as reported by staff nurses in two cities in Turkey. Hospital ownership status, employment status were examined for their effect on this influence. The reported influence of organizational variables on job performance was measured by a questionnaire developed for this study. Nurses were asked to evaluate the influence of 28 organizational variables on their job performance using a five-point Likert-type scale (1- Never effective, 5- Very effective). The study used comparative and descriptive study design. The staff nurses who were included in this study were 831 hospital staff nurses. Descriptive statistics, frequencies, t-test, ANOVA and factor analysis were used for data analysis. The study showed the relative importance of the 28 organizational variables in influencing nurses' job performance. Nurses in this study reported that workload and technological support are the most influential organizational variables on their job performance. Factor analysis yielded a five-factor model that explained 53.99% of total variance. Administratively controllable influence job organizational variables influence job performance of nurses in different magnitude.

  13. XO-2b: A HOT JUPITER WITH A VARIABLE HOST STAR THAT POTENTIALLY AFFECTS ITS MEASURED TRANSIT DEPTH

    International Nuclear Information System (INIS)

    Zellem, Robert T.; Griffith, Caitlin A.; Pearson, Kyle A.; Fitzpatrick, M. Ryleigh; Teske, Johanna K.; Biddle, Lauren I.; Turner, Jake D.; Henry, Gregory W.; Williamson, Michael H.

    2015-01-01

    The transiting hot Jupiter XO-2b is an ideal target for multi-object photometry and spectroscopy as it has a relatively bright (V-mag = 11.25) K0V host star (XO-2N) and a large planet-to-star contrast ratio (R p /R s ≈ 0.015). It also has a nearby (31.″21) binary stellar companion (XO-2S) of nearly the same brightness (V-mag = 11.20) and spectral type (G9V), allowing for the characterization and removal of shared systematic errors (e.g., airmass brightness variations). We have therefore conducted a multiyear (2012–2015) study of XO-2b with the University of Arizona’s 61″ (1.55 m) Kuiper Telescope and Mont4k CCD in the Bessel U and Harris B photometric passbands to measure its Rayleigh scattering slope to place upper limits on the pressure-dependent radius at, e.g., 10 bar. Such measurements are needed to constrain its derived molecular abundances from primary transit observations. We have also been monitoring XO-2N since the 2013–2014 winter season with Tennessee State University’s Celestron-14 (0.36 m) automated imaging telescope to investigate stellar variability, which could affect XO-2b’s transit depth. Our observations indicate that XO-2N is variable, potentially due to cool star spots, with a peak-to-peak amplitude of 0.0049 ± 0.0007 R-mag and a period of 29.89 ± 0.16 days for the 2013–2014 observing season and a peak-to-peak amplitude of 0.0035 ± 0.0007 R-mag and 27.34 ± 0.21 day period for the 2014–2015 observing season. Because of the likely influence of XO-2N’s variability on the derivation of XO-2b’s transit depth, we cannot bin multiple nights of data to decrease our uncertainties, preventing us from constraining its gas abundances. This study demonstrates that long-term monitoring programs of exoplanet host stars are crucial for understanding host star variability

  14. A composite model including visfatin, tissue polypeptide-specific antigen, hyaluronic acid, and hematological variables for the diagnosis of moderate-to-severe fibrosis in nonalcoholic fatty liver disease: a preliminary study.

    Science.gov (United States)

    Chwist, Alina; Hartleb, Marek; Lekstan, Andrzej; Kukla, Michał; Gutkowski, Krzysztof; Kajor, Maciej

    2014-01-01

    Histopathological risk factors for end-stage liver failure in patients with nonalcoholic fatty liver disease (NAFLD) include nonalcoholic steatohepatitis (NASH) and advanced liver fibrosis. There is a need for noninvasive diagnostic methods for these 2 conditions. The aim of this study was to investigate new laboratory variables with a predictive potential to detect advanced fibrosis (stages 2 and 3) in NAFLD. The study involved 70 patients with histologically proven NAFLD of varied severity. Additional laboratory variables included zonulin, haptoglobin, visfatin, adiponectin, leptin, tissue polypeptide-specific antigen (TPSA), hyaluronic acid, and interleukin 6. Patients with NASH (NAFLD activity score of ≥5) had significantly higher HOMA-IR values and serum levels of visfatin, haptoglobin, and zonulin as compared with those without NASH on histological examination. Advanced fibrosis was found in 16 patients (22.9%) and the risk factors associated with its prevalence were age, the ratio of erythrocyte count to red blood cell distribution width, platelet count, and serum levels of visfatin and TPSA. Based on these variables, we constructed a scoring system that differentiated between NAFLD patients with and without advanced fibrosis with a sensitivity of 75% and specificity of 100% (area under the receiver operating characteristic curve, 0.93). The scoring system based on the above variables allows to predict advanced fibrosis with high sensitivity and specificity. However, its clinical utility should be verified in further studies involving a larger number of patients.

  15. Polarimetry of magnetic catalysmic variables

    Energy Technology Data Exchange (ETDEWEB)

    Cropper, M

    1985-01-01

    The design and construction of an astronomical polarimeter is described and an evaluation made of its performance. Extensive observations of cataclysmic variables with emphasis on the AM Her and DQ Her classes are then presented. The polarimeter permitted simultaneous linear and circular polarisation measurements, or, by rearranging the order of the retarders in the beam, linear polarisation measurements alone, or circular polarisation measurements alone, with enhanced efficiency. Extensive sets of observations using the polarimeter were obtained for six of the ten AM Her variables. A comparison was made between the competing models for the cyclotron emission, showing that those which take into account the temperature structure of the accretion region provide the best results.

  16. Measurement of the 36Cl deposition flux in central Japan: natural background levels and seasonal variability

    International Nuclear Information System (INIS)

    Tosaki, Yuki; Tase, Norio; Sasa, Kimikazu; Takahashi, Tsutomu; Nagashima, Yasuo

    2012-01-01

    Essential parameters for the applications of 36 Cl as a tracer in groundwater studies include the initial 36 Cl/Cl ratio, at the time of recharge, and/or the natural background deposition flux of 36 Cl in the recharge area. To facilitate the hydrological use of 36 Cl in central Japan, this study aimed to obtain a precise estimate of the long-term average local 36 Cl flux and to characterize its seasonal variability. The 36 Cl in precipitation was continuously monitored in Tsukuba, central Japan over a period of >5 years. The 36 Cl flux showed a clear seasonal variation with an annual peak during the spring, which was attributed to the seasonal variability of tropopause height. The long-term average 36 Cl flux (32 ± 2 atoms m −2 s −1 ), estimated from the measured data, was consistent with the prediction from the 36 Cl latitudinal fallout model scaled using the global mean production rate of 20 atoms m −2 s −1 . The initial 36 Cl/Cl ratio was estimated to be (41 ± 6) × 10 −15 , which is similar to that of pre-bomb groundwater in the Tsukuba Upland. An observation period covering an 11-year solar cycle would yield more accurate estimates of the values, given the increased 36 Cl flux during the solar minimum. - Highlights: ► We monitored 36 Cl in precipitation in central Japan over a period of >5 years. ► The 36 Cl flux varied seasonally, with a peak in spring. ► The long-term average 36 Cl flux and the initial 36 Cl/Cl ratio were 32 ± 2 atoms m −2 s −1 and (41 ± 6) × 10 −15 , respectively. ► An observation period covering an 11-year solar cycle would yield more accurate estimates of the values, given the increased 36 Cl flux during the solar minimum.

  17. Empowerment variables for rehabilitation clients on perceived beliefs concerning work quality of life domains.

    Science.gov (United States)

    Tschopp, Molly K; Frain, Michael P; Bishop, Malachy

    2009-01-01

    This article describes and presents an initial analysis of variables generally associated with empowerment towards perceived beliefs concerning quality of life work domains for individuals with disabilities. The model examines the domains of importance, satisfaction, control and degree of interference of disability that an individual feels towards work. The internet based study used results from 70 individuals with disabilities in varying aspects of work. The variables composing empowerment that correlated strongly with the work domains include: self-advocacy, self-efficacy, perceived stigma, and family resiliency as measured through coping. Quality of Life concerning work was measured through the DSC-C a domain specific QOL instrument.

  18. X-Ray Variability Characteristics of the Seyfert 1 Galaxy NGC 3783

    Science.gov (United States)

    Markowitz, A.

    2005-12-01

    We have characterized the energy-dependent X-ray variability properties of the Seyfert 1 galaxy NGC 3783 using archival XMM-Newton and Rossi X-Ray Timing Explorer data. The high-frequency fluctuation power spectral density function (PSD) slope is consistent with flattening toward higher energies. Light-curve cross-correlation functions yield no significant lags, but peak coefficients generally decrease as energy separation of the bands increases on both short and long timescales. We have measured the coherence between various X-ray bands over the temporal frequency range of 6×10-8-1×10-4 Hz; this range includes the temporal frequency of the low-frequency PSD break tentatively detected by Markowitz et al. and includes the lowest temporal frequency over which coherence has been measured in any active galactic nucleus to date. Coherence is generally near unity at these temporal frequencies, although it decreases slightly as energy separation of the bands increases. Temporal frequency-dependent phase lags are detected on short timescales; phase lags are consistent with increasing as energy separation increases or as temporal frequency decreases. All of these results are similar to those obtained previously for several Seyfert galaxies and stellar mass black hole systems. Qualitatively, these results are consistent with the variability models of Kotov et al. and Lyubarskii, wherein the X-ray variability is due to inwardly propagating variations in the local mass accretion rate.

  19. Evidence for lower variability of coronary artery calcium mineral mass measurements by multi-detector computed tomography in a community-based cohort-Consequences for progression studies

    International Nuclear Information System (INIS)

    Hoffmann, Udo; Siebert, Uwe; Bull-Stewart, Arabella; Achenbach, Stephan; Ferencik, Maros; Moselewski, Fabian; Brady, Thomas J.; Massaro, Joseph M.; O'Donnell, Christopher J.

    2006-01-01

    Purpose: To compare the measurement variability for coronary artery calcium (CAC) measurements using mineral mass compared with a modified Agatston score (AS) or volume score (VS) with multi-detector CT (MDCT) scanning, and to estimate the potential impact of these methods on the design of CAC progression studies. Materials and methods: We studied 162 consecutive subjects (83 women, 79 men, mean age 51 ± 11 years) from a general Caucasian community-based cohort (Framingham Heart Study) with duplicate runs of prospective electrocardiographically-triggered MDCT scanning. Each scan was independently evaluated for the presence of CAC by four experienced observers who determined a 'modified' AS, VS and mineral mass. Results: Of the 162 subjects, CAC was detected in both scans in 69 (42%) and no CAC was detected in either scan in 72 (45%). Calcium scores were low in the 21/162 subjects (12%) for whom CAC was present in one but not the other scan (modified AS 0.96). However, the mean interscan variability was significantly different between mineral mass, modified AS, and VS (coefficient of variation 26 ± 19%, 41 ± 28% and 34 ± 25%, respectively; p < 0.04), with significantly smaller mean differences in pair-wise comparisons for mineral mass compared with modified AS (p < 0.002) or with VS (p < 0.03). The amount of CAC but not heart rate was an independent predictor of interscan variability (r = -0.638, -0.614 and -0.577 for AS, VS, and mineral mass, respectively; all p < 0.0001). The decreased interscan variability of mineral mass would allow a sample size reduction of 5.5% compared with modified AS for observational studies of CAC progression and for randomized clinical trials. Conclusion: There is significantly reduced interscan variability of CAC measurements with mineral mass compared with the modified AS or VS. However, the measurement variability of all quantification methods is predicted by the amount of CAC and is inversely correlated to the extent of partial

  20. Metaiodobenzylguanidine and heart rate variability in heart failure

    International Nuclear Information System (INIS)

    Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko

    1998-01-01

    It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac 123 I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)

  1. Metaiodobenzylguanidine and heart rate variability in heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko [Hamamatsu Univ., Shizuoka (Japan). School of Medicine; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko

    1998-10-01

    It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)

  2. Examination of temporal and spatial variability of NO2 VCDs measured using mobile-MAX-DOAS in Toronto, Canada.

    Science.gov (United States)

    Davis, Zoe; Baray, Sabour; Khanbabkhani, Aida; Fujs, William; Csukat, Csilla; McLaren, Robert

    2017-04-01

    Mobile-MAX-DOAS is an innovative technique used to estimate pollutant emission rates and validate satellite measurements and air quality models. It is essential to identify and examine factors that can significantly impact the accuracy of this developing technique. Mobile-MAX-DOAS measurements were conducted in Toronto, Canada with a mini-MAX-DOAS instrument mounted (pointing backwards) on top of a car during August and September, 2016. Scattered sunlight spectra were collected every 45 seconds in the continuously repeated sequence of elevation angles of 30o, 30o, 30o, 30o, 40o, 30o, 90o. Tropospheric VCDs were determined using the geometric approximation from DSCDs fitted using a near-noon, low NO2 VCD FRS spectrum. The study goal was to examine the validity of the assumption that VCDs remain relatively constant at each measured location on a driving route encircling an urban area of interest with typical time periods of 1.5-3 hours to estimate emissions and whether driving direction significantly impacts results. NO2 VCD temporal variability was therefore determined by repeating driving routes in both directions in quick succession on multiple days. Strong temporal variability in NO2 VCDs of up to a factor of two were observed for some routes for the same vehicle locations under constant prevailing wind conditions within cities of up to 90 mg m-2hr-1. This work will be used as a baseline experiment to apply this method in other Canadian cities.

  3. Superpartner Mass Measurement Technique using 1D Orthogonal Decompositions of the Cambridge Transverse Mass Variable MT2

    Science.gov (United States)

    Konar, Partha; Kong, Kyoungchul; Matchev, Konstantin T.; Park, Myeonghun

    2010-07-01

    We propose a new model-independent technique for mass measurements in missing energy events at hadron colliders. We illustrate our method with the most challenging case of a single-step decay chain. We consider inclusive same-sign chargino pair production in supersymmetry, followed by leptonic decays to sneutrinos χ+χ+→ℓ+ℓ'+ν˜ℓν˜ℓ' and invisible decays ν˜ℓ→νℓχ˜10. We introduce two one-dimensional decompositions of the Cambridge MT2 variable: MT2∥ and MT2⊥, on the direction of the upstream transverse momentum P→T and the direction orthogonal to it, respectively. We show that the sneutrino mass Mc can be measured directly by minimizing the number of events N(M˜c) in which MT2 exceeds a certain threshold, conveniently measured from the end point MT2⊥max⁡(M˜c).

  4. Reliability and short-term intra-individual variability of telomere length measurement using monochrome multiplexing quantitative PCR.

    Directory of Open Access Journals (Sweden)

    Sangmi Kim

    Full Text Available Studies examining the association between telomere length and cancer risk have often relied on measurement of telomere length from a single blood draw using a real-time PCR technique. We examined the reliability of telomere length measurement using sequential samples collected over a 9-month period.Relative telomere length in peripheral blood was estimated using a single tube monochrome multiplex quantitative PCR assay in blood DNA samples from 27 non-pregnant adult women (aged 35 to 74 years collected in 7 visits over a 9-month period. A linear mixed model was used to estimate the components of variance for telomere length measurements attributed to variation among women and variation between time points within women. Mean telomere length measurement at any single visit was not significantly different from the average of 7 visits. Plates had a significant systematic influence on telomere length measurements, although measurements between different plates were highly correlated. After controlling for plate effects, 64% of the remaining variance was estimated to be accounted for by variance due to subject. Variance explained by time of visit within a subject was minor, contributing 5% of the remaining variance.Our data demonstrate good short-term reliability of telomere length measurement using blood from a single draw. However, the existence of technical variability, particularly plate effects, reinforces the need for technical replicates and balancing of case and control samples across plates.

  5. Assessing Factors Related to Waist Circumference and Obesity: Application of a Latent Variable Model

    OpenAIRE

    Dalvand, Sahar; Koohpayehzadeh, Jalil; Karimlou, Masoud; Asgari, Fereshteh; Rafei, Ali; Seifi, Behjat; Niksima, Seyed Hassan; Bakhshi, Enayatollah

    2015-01-01

    Background. Because the use of BMI (Body Mass Index) alone as a measure of adiposity has been criticized, in the present study our aim was to fit a latent variable model to simultaneously examine the factors that affect waist circumference (continuous outcome) and obesity (binary outcome) among Iranian adults. Methods. Data included 18,990 Iranian individuals aged 20–65 years that are derived from the third National Survey of Noncommunicable Diseases Risk Factors in Iran. Using latent variabl...

  6. Validity of (Ultra-)Short Recordings for Heart Rate Variability Measurements

    NARCIS (Netherlands)

    Muñoz Venegas, Loretto; van Roon, Arie; Riese, Harriette; Thio, Chris; Oostenbroek, Emma; Westrik, Iris; de Geus, Eco J. C.; Gansevoort, Ron; Lefrandt, Joop; Nolte, Ilja M.; Snieder, Harold

    2015-01-01

    Objectives In order to investigate the applicability of routine 10s electrocardiogram (ECG) recordings for time-domain heart rate variability (HRV) calculation we explored to what extent these (ultra-)short recordings capture the "actual" HRV. Methods The standard deviation of normal-to-normal

  7. THE TIME DOMAIN SPECTROSCOPIC SURVEY: VARIABLE SELECTION AND ANTICIPATED RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Morganson, Eric; Green, Paul J. [Harvard Smithsonian Center for Astrophysics, 60 Garden St, Cambridge, MA 02138 (United States); Anderson, Scott F.; Ruan, John J. [Department of Astronomy, University of Washington, Box 351580, Seattle, WA 98195 (United States); Myers, Adam D. [Department of Physics and Astronomy, University of Wyoming, Laramie, WY 82071 (United States); Eracleous, Michael; Brandt, William Nielsen [Department of Astronomy and Astrophysics, 525 Davey Laboratory, The Pennsylvania State University, University Park, PA 16802 (United States); Kelly, Brandon [Department of Physics, Broida Hall, University of California, Santa Barbara, CA 93106-9530 (United States); Badenes, Carlos [Department of Physics and Astronomy and Pittsburgh Particle Physics, Astrophysics and Cosmology Center (PITT PACC), University of Pittsburgh, 3941 O’Hara St, Pittsburgh, PA 15260 (United States); Bañados, Eduardo [Max-Planck-Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Blanton, Michael R. [Center for Cosmology and Particle Physics, Department of Physics, New York University, 4 Washington Place, New York, NY 10003 (United States); Bershady, Matthew A. [Department of Astronomy, University of Wisconsin, 475 N. Charter St., Madison, WI 53706 (United States); Borissova, Jura [Instituto de Física y Astronomía, Universidad de Valparaíso, Av. Gran Bretaña 1111, Playa Ancha, Casilla 5030, and Millennium Institute of Astrophysics (MAS), Santiago (Chile); Burgett, William S. [GMTO Corp, Suite 300, 251 S. Lake Ave, Pasadena, CA 91101 (United States); Chambers, Kenneth, E-mail: emorganson@cfa.harvard.edu [Institute for Astronomy, University of Hawaii at Manoa, Honolulu, HI 96822 (United States); and others

    2015-06-20

    We present the selection algorithm and anticipated results for the Time Domain Spectroscopic Survey (TDSS). TDSS is an Sloan Digital Sky Survey (SDSS)-IV Extended Baryon Oscillation Spectroscopic Survey (eBOSS) subproject that will provide initial identification spectra of approximately 220,000 luminosity-variable objects (variable stars and active galactic nuclei across 7500 deg{sup 2} selected from a combination of SDSS and multi-epoch Pan-STARRS1 photometry. TDSS will be the largest spectroscopic survey to explicitly target variable objects, avoiding pre-selection on the basis of colors or detailed modeling of specific variability characteristics. Kernel Density Estimate analysis of our target population performed on SDSS Stripe 82 data suggests our target sample will be 95% pure (meaning 95% of objects we select have genuine luminosity variability of a few magnitudes or more). Our final spectroscopic sample will contain roughly 135,000 quasars and 85,000 stellar variables, approximately 4000 of which will be RR Lyrae stars which may be used as outer Milky Way probes. The variability-selected quasar population has a smoother redshift distribution than a color-selected sample, and variability measurements similar to those we develop here may be used to make more uniform quasar samples in large surveys. The stellar variable targets are distributed fairly uniformly across color space, indicating that TDSS will obtain spectra for a wide variety of stellar variables including pulsating variables, stars with significant chromospheric activity, cataclysmic variables, and eclipsing binaries. TDSS will serve as a pathfinder mission to identify and characterize the multitude of variable objects that will be detected photometrically in even larger variability surveys such as Large Synoptic Survey Telescope.

  8. Urban-Related Environmental Variables and Their Relation with Patterns in Biological Community Structure in the Fountain Creek Basin, Colorado, 2003-2005

    Science.gov (United States)

    Zuellig, Robert E.; Bruce, James F.; Evans, Erin E.; Stogner, Sr., Robert W.

    2007-01-01

    In 2003, the U.S. Geological Survey, in cooperation with Colorado Springs City Engineering, began a study to evaluate the influence of urbanization on stream ecosystems. To accomplish this task, invertebrate, fish, stream discharge, habitat, water-chemistry, and land-use data were collected from 13 sites in the Fountain Creek basin from 2003 to 2005. The Hydrologic Index Tool was used to calculate hydrologic indices known to be related to urbanization. Response of stream hydrology to urbanization was evident among hydrologic variables that described stormflow. These indices included one measurement of high-flow magnitude, two measurements of high-flow frequency, and one measurement of stream flashiness. Habitat and selected nonstormflow water chemistry were characterized at each site. Land-use data were converted to estimates of impervious surface cover and used as the measure of urbanization annually. Correlation analysis (Spearman?s rho) was used to identify a suite of nonredundant streamflow, habitat, and water-chemistry variables that were strongly associated (rho > 0.6) with impervious surface cover but not strongly related to elevation (rho analysis (BIO-ENV, PRIMER ver 6.1, Plymouth, UK) was used to create subsets of eight urban-related environmental variables that described patterns in biological community structure. The strongest and most parsimonious subset of variables describing patterns in invertebrate community structure included high flood pulse count, lower bank capacity, and nutrients. Several other combinations of environmental variables resulted in competing subsets, but these subsets always included the three variables found in the most parsimonious list. This study found that patterns in invertebrate community structure from 2003 to 2005 in the Fountain Creek basin were associated with a variety of environmental characteristics influenced by urbanization. These patterns were explained by a combination of hydrologic, habitat, and water

  9. Soil variability in engineering applications

    Science.gov (United States)

    Vessia, Giovanna

    2014-05-01

    Natural geomaterials, as soils and rocks, show spatial variability and heterogeneity of physical and mechanical properties. They can be measured by in field and laboratory testing. The heterogeneity concerns different values of litho-technical parameters pertaining similar lithological units placed close to each other. On the contrary, the variability is inherent to the formation and evolution processes experienced by each geological units (homogeneous geomaterials on average) and captured as a spatial structure of fluctuation of physical property values about their mean trend, e.g. the unit weight, the hydraulic permeability, the friction angle, the cohesion, among others. The preceding spatial variations shall be managed by engineering models to accomplish reliable designing of structures and infrastructures. Materon (1962) introduced the Geostatistics as the most comprehensive tool to manage spatial correlation of parameter measures used in a wide range of earth science applications. In the field of the engineering geology, Vanmarcke (1977) developed the first pioneering attempts to describe and manage the inherent variability in geomaterials although Terzaghi (1943) already highlighted that spatial fluctuations of physical and mechanical parameters used in geotechnical designing cannot be neglected. A few years later, Mandelbrot (1983) and Turcotte (1986) interpreted the internal arrangement of geomaterial according to Fractal Theory. In the same years, Vanmarcke (1983) proposed the Random Field Theory providing mathematical tools to deal with inherent variability of each geological units or stratigraphic succession that can be resembled as one material. In this approach, measurement fluctuations of physical parameters are interpreted through the spatial variability structure consisting in the correlation function and the scale of fluctuation. Fenton and Griffiths (1992) combined random field simulation with the finite element method to produce the Random

  10. Measures of Disadvantage: Is Car Ownership a Good Indicator?

    Science.gov (United States)

    Johnson, Victoria; Currie, Graham; Stanley, Janet

    2010-01-01

    A need to better understand the multidimensional nature of disadvantage is leading to the adoption of a wider range of measurement variables. One variable now commonly adopted is zero car ownership. This paper challenges the logic of including "not having a car" as an indicator of disadvantage. It argues that this can distort the real picture of…

  11. Two-color photographic photometry of variables in the globular cluster M28

    International Nuclear Information System (INIS)

    Wehlau, A.; Butterworth, S.

    1990-01-01

    Visual magnitudes have been measured for 20 variables on 32 plates of M28. These have been combined with previously published as well as newly determined blue magnitudes in order to obtain colors for the variables. Blue and visual light curves are presented for 15 of the the variables, including one W Virginis star V4, one RV Tauri star V17, one field Mira variable V7, nine cluster RR Lyrae stars, and three field RR Lyrae stars. It is shown that V14, previously thought to be a c type RR Lyrae star, is to the red of the instability strip. The visual light curve of V9 suggests that the star may be a member of a binary or a very close optical double. Possible evidence for differential reddening in the vicinity of M28 is presented. The bimodal distribution of the periods of the RR Lyrae stars in M28 may indicate a spread in metallicity among the RR Lyrae variables. 16 refs

  12. Quantifying decoherence in continuous variable systems

    Energy Technology Data Exchange (ETDEWEB)

    Serafini, A [Dipartimento di Fisica ' ER Caianiello' , Universita di Salerno, INFM UdR Salerno, INFN Sezione Napoli, Gruppo Collegato Salerno, Via S Allende, 84081 Baronissi, SA (Italy); Paris, M G A [Dipartimento di Fisica and INFM, Universita di Milano, Milan (Italy); Illuminati, F [Dipartimento di Fisica ' ER Caianiello' , Universita di Salerno, INFM UdR Salerno, INFN Sezione Napoli, Gruppo Collegato Salerno, Via S Allende, 84081 Baronissi, SA (Italy); De Siena, S [Dipartimento di Fisica ' ER Caianiello' , Universita di Salerno, INFM UdR Salerno, INFN Sezione Napoli, Gruppo Collegato Salerno, Via S Allende, 84081 Baronissi, SA (Italy)

    2005-04-01

    We present a detailed report on the decoherence of quantum states of continuous variable systems under the action of a quantum optical master equation resulting from the interaction with general Gaussian uncorrelated environments. The rate of decoherence is quantified by relating it to the decay rates of various, complementary measures of the quantum nature of a state, such as the purity, some non-classicality indicators in phase space, and, for two-mode states, entanglement measures and total correlations between the modes. Different sets of physically relevant initial configurations are considered, including one- and two-mode Gaussian states, number states, and coherent superpositions. Our analysis shows that, generally, the use of initially squeezed configurations does not help to preserve the coherence of Gaussian states, whereas it can be effective in protecting coherent superpositions of both number states and Gaussian wavepackets. (review article)

  13. Quantifying decoherence in continuous variable systems

    International Nuclear Information System (INIS)

    Serafini, A; Paris, M G A; Illuminati, F; De Siena, S

    2005-01-01

    We present a detailed report on the decoherence of quantum states of continuous variable systems under the action of a quantum optical master equation resulting from the interaction with general Gaussian uncorrelated environments. The rate of decoherence is quantified by relating it to the decay rates of various, complementary measures of the quantum nature of a state, such as the purity, some non-classicality indicators in phase space, and, for two-mode states, entanglement measures and total correlations between the modes. Different sets of physically relevant initial configurations are considered, including one- and two-mode Gaussian states, number states, and coherent superpositions. Our analysis shows that, generally, the use of initially squeezed configurations does not help to preserve the coherence of Gaussian states, whereas it can be effective in protecting coherent superpositions of both number states and Gaussian wavepackets. (review article)

  14. Examining Impulse-Variability in Kicking.

    Science.gov (United States)

    Chappell, Andrew; Molina, Sergio L; McKibben, Jonathon; Stodden, David F

    2016-07-01

    This study examined variability in kicking speed and spatial accuracy to test the impulse-variability theory prediction of an inverted-U function and the speed-accuracy trade-off. Twenty-eight 18- to 25-year-old adults kicked a playground ball at various percentages (50-100%) of their maximum speed at a wall target. Speed variability and spatial error were analyzed using repeated-measures ANOVA with built-in polynomial contrasts. Results indicated a significant inverse linear trajectory for speed variability (p < .001, η2= .345) where 50% and 60% maximum speed had significantly higher variability than the 100% condition. A significant quadratic fit was found for spatial error scores of mean radial error (p < .0001, η2 = .474) and subject-centroid radial error (p < .0001, η2 = .453). Findings suggest variability and accuracy of multijoint, ballistic skill performance may not follow the general principles of impulse-variability theory or the speed-accuracy trade-off.

  15. Intra-individual variability in day-to-day and month-to-month measurements of physical activity and sedentary behaviour at work and in leisure-time among Danish adults

    DEFF Research Database (Denmark)

    Lunde Pedersen, Eva Sophie; Danquah, I H; Petersen, C B

    2016-01-01

    in accelerometer derived data on sedentary behaviour and physical activity at work and in leisure-time during week days among Danish office employees. METHODS: We included control participants (n = 135) from the Take a Stand! Intervention; a cluster randomized controlled trial conducted in 19 offices. Sitting time....... RESULTS: Results of this study showed that the number of days needed to obtain a reliability of 80% when measuring sitting time was 4.7 days for work and 5.5 days for leisure time. For physical activity at work, 4.0 days and 4.2 days were required to measure steps and MVPA, respectively. During leisure...... time, more monitoring time was needed to reliably estimate physical activity (6.8 days for steps and 5.8 days for MVPA). CONCLUSIONS: The number of measurement days needed to reliably estimate activity patterns was greater for leisure time than for work time. The domain specific variability is of great...

  16. Norepinephrine genes predict response time variability and methylphenidate-induced changes in neuropsychological function in attention deficit hyperactivity disorder.

    Science.gov (United States)

    Kim, Bung-Nyun; Kim, Jae-Won; Cummins, Tarrant D R; Bellgrove, Mark A; Hawi, Ziarih; Hong, Soon-Beom; Yang, Young-Hui; Kim, Hyo-Jin; Shin, Min-Sup; Cho, Soo-Churl; Kim, Ji-Hoon; Son, Jung-Woo; Shin, Yun-Mi; Chung, Un-Sun; Han, Doug-Hyun

    2013-06-01

    Noradrenergic dysfunction may be associated with cognitive impairments in attention-deficit/hyperactivity disorder (ADHD), including increased response time variability, which has been proposed as a leading endophenotype for ADHD. The aim of this study was to examine the relationship between polymorphisms in the α-2A-adrenergic receptor (ADRA2A) and norepinephrine transporter (SLC6A2) genes and attentional performance in ADHD children before and after pharmacological treatment.One hundred one medication-naive ADHD children were included. All subjects were administered methylphenidate (MPH)-OROS for 12 weeks. The subjects underwent a computerized comprehensive attention test to measure the response time variability at baseline before MPH treatment and after 12 weeks. Additive regression analyses controlling for ADHD symptom severity, age, sex, IQ, and final dose of MPH examined the association between response time variability on the comprehensive attention test measures and allelic variations in single-nucleotide polymorphisms of the ADRA2A and SLC6A2 before and after MPH treatment.Increasing possession of an A allele at the G1287A polymorphism of SLC6A2 was significantly related to heightened response time variability at baseline in the sustained (P = 2.0 × 10) and auditory selective attention (P = 1.0 × 10) tasks. Response time variability at baseline increased additively with possession of the T allele at the DraI polymorphism of the ADRA2A gene in the auditory selective attention task (P = 2.0 × 10). After medication, increasing possession of a G allele at the MspI polymorphism of the ADRA2A gene was associated with increased MPH-related change in response time variability in the flanker task (P = 1.0 × 10).Our study suggested an association between norepinephrine gene variants and response time variability measured at baseline and after MPH treatment in children with ADHD. Our results add to a growing body of evidence, suggesting that response time

  17. Psychosocial variables of sexual satisfaction in Chile.

    Science.gov (United States)

    Barrientos, Jaime E; Páez, Dario

    2006-01-01

    This study analyzed psychosocial variables of sexual satisfaction in Chile using data from the COSECON survey. Participants were 5,407 subjects (2,244 min and 3,163 women, aged 18-69 years). We used a cross-sectional questionnaire with a national probability sample. Data were collected using a thorough sexual behavior questionnaire consisting of 190 face-to-face questions and 24 self-reported questions. A single item included in the COSECON questionnaire assessed sexual satisfaction. Results showed that high education level, marital status, and high socioeconomic levels were associated with sexual satisfaction in women but not in men. The results also showed important gender differences and sustain the idea that sexuality changes may be more present in middle and high social classes. The proximal variables typically used for measuring sexual satisfaction, such as the frequency of sexual intercourse and orgasm, showed a positive but smaller association with sexual satisfaction. Other important variables related to sexual satisfaction were being in love with the partner and having a steady partner. The results confirmed previous findings and are discussed in the frame of approaches like the exchange, equity, and sexual scripts theories.

  18. Variables Influencing Credit Card Balances of Students at a Midwestern University

    Science.gov (United States)

    Mattson, Lucretia; Sahlhoff, Kathleen; Blackstone, Judith; Peden, Blaine; Nahm, Abraham Y.

    2004-01-01

    This research used a Web-based survey of students at a Midwest regional university to measure the extent of credit card use by first-year students and seniors. The results indicate that the variables influencing credit card use and the carrying of a balance from one month to the next include the number of cards held by the student, the student's…

  19. Respiratory variability preceding and following sighs: a resetter hypothesis.

    Science.gov (United States)

    Vlemincx, Elke; Van Diest, Ilse; Lehrer, Paul M; Aubert, André E; Van den Bergh, Omer

    2010-04-01

    Respiratory behavior is characterized by complex variability with structured and random components. Assuming that both a lack of variability and too much randomness represent suboptimal breathing regulation, we hypothesized that sighing acts as a resetter inducing structured variability. Spontaneous breathing was measured in healthy persons (N=42) during a 20min period of quiet sitting using the LifeShirt(®) System. Four blocks of 10 breaths with a 50% window overlap were determined before and after spontaneous sighs. Total respiratory variability of minute ventilation was measured using the coefficient of variation and structured (correlated) variability was quantified using autocorrelation. Towards a sigh, total variability gradually increased without concomittant changes in correlated variability, suggesting that randomness increased. After a sigh, correlated variability increased. No changes in variability were found in comparable epochs without intermediate sighs. We conclude that a sigh resets structured respiratory variability, enhancing information processing in the respiratory system. Copyright © 2009 Elsevier B.V. All rights reserved.

  20. Patient and organisational variables associated with pressure ulcer prevalence in hospital settings: a multilevel analysis.

    Science.gov (United States)

    Bredesen, Ida Marie; Bjøro, Karen; Gunningberg, Lena; Hofoss, Dag

    2015-08-27

    To investigate the association of ward-level differences in the odds of hospital-acquired pressure ulcers (HAPUs) with selected ward organisational variables and patient risk factors. Multilevel approach to data from 2 cross-sectional studies. 4 hospitals in Norway were studied. 1056 patients at 84 somatic wards. HAPU. Significant variance in the odds of HAPUs was found across wards. A regression model using only organisational variables left a significant variance in the odds of HAPUs across wards but patient variables eliminated the across-ward variance. In the model including organisational and patient variables, significant ward-level HAPU variables were ward type (rehabilitation vs surgery/internal medicine: OR 0.17 (95% CI 0.04 to 0.66)), use of preventive measures (yes vs no: OR 2.02 (95% CI 1.12 to 3.64)) and ward patient safety culture (OR 0.97 (95% CI 0.96 to 0.99)). Significant patient-level predictors were age >70 vs organisation of care improvements, that is, by improving the patient safety culture and implementation of preventive measures. Some wards may prevent pressure ulcers better than other wards. The fact that ward-level variation was eliminated when patient-level HAPU variables were included in the model indicates that even wards with the best HAPU prevention will be challenged by an influx of high-risk patients. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Microscopic age determination of human skeletons including an unknown but calculable variable

    DEFF Research Database (Denmark)

    Wallin, Johan Albert; Tkocz, Izabella; Kristensen, Gustav

    1994-01-01

    estimation, which includes the covariance matrix of four single equation residuals, improves the accuracy of age determination. The standard deviation, however, of age prediction remains 12.58 years. An experimental split of the data was made in order to demonstrate that the use of subgroups gives a false...

  2. [Motivation perception measurement of intermediate directors in three complex hospitals of the Region of the Maule, Chile].

    Science.gov (United States)

    Bustamante-Ubilla, Miguel Alejandro; del Río-Rivero, María Carolina; Lobos-Andrade, Germán Enrique; Villarreal-Navarrete, Patricia Isabel

    2009-01-01

    In this work, a questionnaire was designed and perceptions of motivation and demotivation of middle managers in three hospitals in the Region del Maule, Chile were measured. The fieldwork was carried out between September and October, 2006. A questionnaire that included 57 statements to measure attitude was administered and qualified according to a five-point Likert-type scale. The population studied included l25 professionals that supervise roughly 3 800 employees. Ten variables were identified, 5 motivational and 5 demotivational. Notable among the motivational variables are vocation and service-oriented spirit; among the demotivational variables are lack of recognition and commitment. It is affirmed that both motivational variables as well as demotivational variables are essentially qualitative and that economic and salary variables are less relevant and less hierarchical.

  3. Do psychological variables affect early surgical recovery?

    Directory of Open Access Journals (Sweden)

    Michael N Mavros

    Full Text Available BACKGROUND: Numerous studies have examined the effect of psychological variables on surgical recovery, but no definite conclusion has been reached yet. We sought to examine whether psychological factors influence early surgical recovery. METHODS: We performed a systematic search in PubMed, Scopus and PsycINFO databases to identify studies examining the association of preoperative psychological variables or interventions with objectively measured, early surgical outcomes. RESULTS: We identified 16 eligible studies, 15 of which reported a significant association between at least one psychological variable or intervention and an early postoperative outcome. However, most studies also reported psychological factors not influencing surgical recovery and there was significant heterogeneity across the studies. Overall, trait and state anxiety, state anger, active coping, subclinical depression, and intramarital hostility appeared to complicate recovery, while dispositional optimism, religiousness, anger control, low pain expectations, and external locus of control seemed to promote healing. Psychological interventions (guided relaxation, couple support visit, and psychiatric interview also appeared to favor recovery. Psychological factors unrelated to surgical outcomes included loneliness, perceived social support, anger expression, and trait anger. CONCLUSION: Although the heterogeneity of the available evidence precludes any safe conclusions, psychological variables appear to be associated with early surgical recovery; this association could bear important implications for clinical practice. Large clinical trials and further analyses are needed to precisely evaluate the contribution of psychology in surgical recovery.

  4. Correlation Between Fracture Network Properties and Stress Variability in Geological Media

    Science.gov (United States)

    Lei, Qinghua; Gao, Ke

    2018-05-01

    We quantitatively investigate the stress variability in fractured geological media under tectonic stresses. The fracture systems studied include synthetic fracture networks following power law length scaling and natural fracture patterns based on outcrop mapping. The stress field is derived from a finite-discrete element model, and its variability is analyzed using a set of mathematical formulations that honor the tensorial nature of stress data. We show that local stress perturbation, quantified by the Euclidean distance of a local stress tensor to the mean stress tensor, has a positive, linear correlation with local fracture intensity, defined as the total fracture length per unit area within a local sampling window. We also evaluate the stress dispersion of the entire stress field using the effective variance, that is, a scalar-valued measure of the overall stress variability. The results show that a well-connected fracture system under a critically stressed state exhibits strong local and global stress variabilities.

  5. Stride dynamics, gait variability and prospective falls risk in active community dwelling older women.

    Science.gov (United States)

    Paterson, Kade; Hill, Keith; Lythgo, Noel

    2011-02-01

    Measures of walking instability such as stride dynamics and gait variability have been shown to identify future fallers in older adult populations with gait limitations or mobility disorders. This study investigated whether measures of walking instability can predict future fallers (over a prospective 12 month period) in a group of healthy and active older women. Ninety-seven healthy active women aged between 55 and 90 years walked for 7 min around a continuous walking circuit. Gait data recorded by a GAITRite(®) walkway and foot-mounted accelerometers were used to calculate measures of stride dynamics and gait variability. The participant's physical function and balance were assessed. Fall incidence was monitored over the following 12 months. Inter-limb differences (p≤0.04) in stride dynamics were found for fallers (one or more falls) aged over 70 years, and multiple fallers (two or more falls) aged over 55 years, but not in non-fallers or a combined group of single and non-fallers. No group differences were found in the measures of physical function, balance or gait, including variability. Additionally, no gait variable predicted falls. Reduced coordination of inter-limb dynamics was found in active healthy older fallers and multiple fallers despite no difference in other measures of intrinsic falls risk. Evaluating inter-limb dynamics may be a clinically sensitive technique to detect early gait instability and falls risk in high functioning older adults, prior to change in other measures of physical function, balance and gait. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. Past and present variability of the solar-terrestrial system: measurement, data analysis and theoretical models

    Energy Technology Data Exchange (ETDEWEB)

    Cini Castagnoli, G.; Provenzale, A. [eds.

    1997-12-31

    The course Past and present variability of the solar-terrestrial system: measurement, data analysis and theoretical models is explicitly devoted to these issues. A solar cycle ago, in summer 1985, G. Cini organized a similar school, in a time when this field was in a very early stage of development and definitely fewer high-quality measurements were available. After eleven years, the field has grown toward becoming a robust scientific discipline, new data have been obtained, and new ideas have been proposed by both solar physicists and climate dynamicists. For this reason, the authors felt that it was the right time to organize a new summer school, with the aim of formalizing the developments that have taken place during these years, and also for speculating and maybe dreaming of new results that will be achieved in the upcoming years. The papers of the lectures have now been collected in this volume. First, in order to know what the authors talking about, they need to obtain reliable data from terrestrial archives,and to properly date the records that have been measured. To these crucial aspects is devoted the first part of the book, dealing with various types of proxy data and with the difficult issue of the dating of the records.

  7. Emotional stress and heart rate variability measures associated with cardiovascular risk in relocated Katrina survivors.

    Science.gov (United States)

    Tucker, Phebe; Pfefferbaum, Betty; Jeon-Slaughter, Haekyung; Khan, Qaiser; Garton, Theresa

    2012-01-01

    To explore the effects of hurricane exposure and forced relocation on the mind and body, we compared psychiatric diagnoses and symptoms with heart rate variability (HRV) for 34 relocated Katrina survivors and 34 demographically matched controls. All participants were healthy and free of psychiatric and cardiovascular medications. We measured symptoms of posttraumatic stress disorder (PTSD) (Clinician-Administered PTSD Scale 1) and depression (Beck Depression Inventory), Axis I psychiatric diagnoses (Structured Clinical Interview for DSM-IV), psychosocial disability (Sheehan Disability Scale), and power spectral analysis HRV reactivity to trauma reminders. Katrina-related PTSD occurred in 38% of survivors and 12% of controls. Survivors reported higher levels of PTSD and depression symptoms, within diagnostic ranges, and greater psychosocial disability than controls. Survivors had higher resting heart rate (80.82 [standard deviation = 13.60] versus 74.85 [10.67], p = .05), lower parasympathetic (high-frequency [HF] normalized unit) baseline HRV activity (40.14 [23.81] versus 50.67 [19.93], p = .04) and less reactivity with trauma cues (-2.63 [20.70] versus -11.96 [15.84], p = .04), and higher baseline sympathovagal activity (low frequency/HF ratio) (2.84 [3.08] versus 1.35 [1.08], p = .04) than controls. Survivors with depression (n = 12) and with depression and PTSD combined (n = 7), but not those with PTSD (n = 13), had flattened parasympathetic responsiveness to trauma cues. HRV indices correlated with depressive (low frequency/HF, p = .01; HF normalized unit, p = .046) but not PTSD symptoms (p values > .05). Results showed this multilayer trauma's impact on emotional health and HRV-based measures of autonomic nervous system dysregulation. Specifically, dysregulation of depressed survivors' HRV in response to trauma reminders supports more autonomic involvement in traumatic loss/depression than in PTSD. Diagnostic criteria for PTSD include physiologic reactivity

  8. Temporal Variability of Observed and Simulated Hyperspectral Earth Reflectance

    Science.gov (United States)

    Roberts, Yolanda; Pilewskie, Peter; Kindel, Bruce; Feldman, Daniel; Collins, William D.

    2012-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) is a climate observation system designed to study Earth's climate variability with unprecedented absolute radiometric accuracy and SI traceability. Observation System Simulation Experiments (OSSEs) were developed using GCM output and MODTRAN to simulate CLARREO reflectance measurements during the 21st century as a design tool for the CLARREO hyperspectral shortwave imager. With OSSE simulations of hyperspectral reflectance, Feldman et al. [2011a,b] found that shortwave reflectance is able to detect changes in climate variables during the 21st century and improve time-to-detection compared to broadband measurements. The OSSE has been a powerful tool in the design of the CLARREO imager and for understanding the effect of climate change on the spectral variability of reflectance, but it is important to evaluate how well the OSSE simulates the Earth's present-day spectral variability. For this evaluation we have used hyperspectral reflectance measurements from the Scanning Imaging Absorption Spectrometer for Atmospheric Cartography (SCIAMACHY), a shortwave spectrometer that was operational between March 2002 and April 2012. To study the spectral variability of SCIAMACHY-measured and OSSE-simulated reflectance, we used principal component analysis (PCA), a spectral decomposition technique that identifies dominant modes of variability in a multivariate data set. Using quantitative comparisons of the OSSE and SCIAMACHY PCs, we have quantified how well the OSSE captures the spectral variability of Earth?s climate system at the beginning of the 21st century relative to SCIAMACHY measurements. These results showed that the OSSE and SCIAMACHY data sets share over 99% of their total variance in 2004. Using the PCs and the temporally distributed reflectance spectra projected onto the PCs (PC scores), we can study the temporal variability of the observed and simulated reflectance spectra. Multivariate time

  9. Variability in large-scale wind power generation: Variability in large-scale wind power generation

    Energy Technology Data Exchange (ETDEWEB)

    Kiviluoma, Juha [VTT Technical Research Centre of Finland, Espoo Finland; Holttinen, Hannele [VTT Technical Research Centre of Finland, Espoo Finland; Weir, David [Energy Department, Norwegian Water Resources and Energy Directorate, Oslo Norway; Scharff, Richard [KTH Royal Institute of Technology, Electric Power Systems, Stockholm Sweden; Söder, Lennart [Royal Institute of Technology, Electric Power Systems, Stockholm Sweden; Menemenlis, Nickie [Institut de recherche Hydro-Québec, Montreal Canada; Cutululis, Nicolaos A. [DTU, Wind Energy, Roskilde Denmark; Danti Lopez, Irene [Electricity Research Centre, University College Dublin, Dublin Ireland; Lannoye, Eamonn [Electric Power Research Institute, Palo Alto California USA; Estanqueiro, Ana [LNEG, Laboratorio Nacional de Energia e Geologia, UESEO, Lisbon Spain; Gomez-Lazaro, Emilio [Renewable Energy Research Institute and DIEEAC/EDII-AB, Castilla-La Mancha University, Albacete Spain; Zhang, Qin [State Grid Corporation of China, Beijing China; Bai, Jianhua [State Grid Energy Research Institute Beijing, Beijing China; Wan, Yih-Huei [National Renewable Energy Laboratory, Transmission and Grid Integration Group, Golden Colorado USA; Milligan, Michael [National Renewable Energy Laboratory, Transmission and Grid Integration Group, Golden Colorado USA

    2015-10-25

    The paper demonstrates the characteristics of wind power variability and net load variability in multiple power systems based on real data from multiple years. Demonstrated characteristics include probability distribution for different ramp durations, seasonal and diurnal variability and low net load events. The comparison shows regions with low variability (Sweden, Spain and Germany), medium variability (Portugal, Ireland, Finland and Denmark) and regions with higher variability (Quebec, Bonneville Power Administration and Electric Reliability Council of Texas in North America; Gansu, Jilin and Liaoning in China; and Norway and offshore wind power in Denmark). For regions with low variability, the maximum 1 h wind ramps are below 10% of nominal capacity, and for regions with high variability, they may be close to 30%. Wind power variability is mainly explained by the extent of geographical spread, but also higher capacity factor causes higher variability. It was also shown how wind power ramps are autocorrelated and dependent on the operating output level. When wind power was concentrated in smaller area, there were outliers with high changes in wind output, which were not present in large areas with well-dispersed wind power.

  10. Both Reaction Time and Accuracy Measures of Intraindividual Variability Predict Cognitive Performance in Alzheimer's Disease

    Directory of Open Access Journals (Sweden)

    Björn U. Christ

    2018-04-01

    Full Text Available Dementia researchers around the world prioritize the urgent need for sensitive measurement tools that can detect cognitive and functional change at the earliest stages of Alzheimer's disease (AD. Sensitive indicators of underlying neural pathology assist in the early detection of cognitive change and are thus important for the evaluation of early-intervention clinical trials. One method that may be particularly well-suited to help achieve this goal involves the quantification of intraindividual variability (IIV in cognitive performance. The current study aimed to directly compare two methods of estimating IIV (fluctuations in accuracy-based scores vs. those in latency-based scores to predict cognitive performance in AD. Specifically, we directly compared the relative sensitivity of reaction time (RT—and accuracy-based estimates of IIV to cognitive compromise. The novelty of the present study, however, centered on the patients we tested [a group of patients with Alzheimer's disease (AD] and the outcome measures we used (a measure of general cognitive function and a measure of episodic memory function. Hence, we compared intraindividual standard deviations (iSDs from two RT tasks and three accuracy-based memory tasks in patients with possible or probable Alzheimer's dementia (n = 23 and matched healthy controls (n = 25. The main analyses modeled the relative contributions of RT vs. accuracy-based measures of IIV toward the prediction of performance on measures of (a overall cognitive functioning, and (b episodic memory functioning. Results indicated that RT-based IIV measures are superior predictors of neurocognitive impairment (as indexed by overall cognitive and memory performance than accuracy-based IIV measures, even after adjusting for the timescale of measurement. However, one accuracy-based IIV measure (derived from a recognition memory test also differentiated patients with AD from controls, and significantly predicted episodic memory

  11. Assessment and quantification of sources of variability in breast apparent diffusion coefficient (ADC) measurements at diffusion weighted imaging

    International Nuclear Information System (INIS)

    Giannotti, E.; Waugh, S.; Priba, L.; Davis, Z.; Crowe, E.; Vinnicombe, S.

    2015-01-01

    Highlights: • Inter-scan errors have minimal contribution to ADC measurement variability. • Intra-observer measures of ADC values in breast cancer are excellent. • ADC measures in whole tumour are more reproducible than minimum ADC measures. • ADC measurement error is most influenced by multiple readers. - Abstract: Purpose: Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may be encountered in such follow-up studies- namely scanner stability, scan–scan reproducibility, inter- and intra- observer measures and the most reproducible measurement of ADC. Methods: Institutional Review Board approval was obtained for the prospective study of healthy volunteers and written consent acquired for the retrospective study of patient images. All scanning was performed on a 3.0-T MRI scanner. Scanner stability was assessed using an ice-water phantom weekly for 12 weeks. Inter-scan repeatability was assessed across two scans of 10 healthy volunteers (26–61 years; mean: 44.7 years). Inter- and intra-reader analysis repeatability was measured in 52 carcinomas from clinical patients (29–70 years; mean: 50.0 years) by measuring the whole tumor ADC value on a single slice with maximum tumor diameter (ADC S ) and the ADC value of a small region of interest (ROI) on the same slice (ADC min ). Repeatability was assessed using intraclass correlation coefficients (ICC) and coefficients of repeatability (CoR). Results: Scanner stability contributed 6% error to phantom ADC measurements (0.071 × 10 −3 mm 2 /s; mean ADC = 1.089 × 10 −3 mm 2 /s). The measured scan-scan CoR in the volunteers was 0.122 × 10 −3 mm 2 /s, contributing an error of 8% to the mean measured values (ADC scan1 = 1.529 × 10 −3 mm 2 /s; ADC scan

  12. XO-2b: A HOT JUPITER WITH A VARIABLE HOST STAR THAT POTENTIALLY AFFECTS ITS MEASURED TRANSIT DEPTH

    Energy Technology Data Exchange (ETDEWEB)

    Zellem, Robert T.; Griffith, Caitlin A. [Department of Planetary Sciences, Lunar and Planetary Laboratory, University of Arizona, 1629 East University Boulevard, University of Arizona, Tucson, AZ 85721 (United States); Pearson, Kyle A.; Fitzpatrick, M. Ryleigh; Teske, Johanna K.; Biddle, Lauren I. [Department of Astronomy, Steward Observatory, University of Arizona, 933 North Cherry Avenue, Tucson, AZ 85721 (United States); Turner, Jake D. [Department of Planetary Sciences, University of Arizona, 933 North Cherry Avenue, Tucson, AZ 85721 (United States); Henry, Gregory W.; Williamson, Michael H., E-mail: rzellem@lpl.arizona.edu, E-mail: griffith@lpl.arizona.edu [Center of Excellence in Information Systems, Tennessee State University, 3500 John A. Merritt Blvd., P.O. Box 9501, Nashville, TN 37209 (United States)

    2015-09-01

    The transiting hot Jupiter XO-2b is an ideal target for multi-object photometry and spectroscopy as it has a relatively bright (V-mag = 11.25) K0V host star (XO-2N) and a large planet-to-star contrast ratio (R{sub p}/R{sub s} ≈ 0.015). It also has a nearby (31.″21) binary stellar companion (XO-2S) of nearly the same brightness (V-mag = 11.20) and spectral type (G9V), allowing for the characterization and removal of shared systematic errors (e.g., airmass brightness variations). We have therefore conducted a multiyear (2012–2015) study of XO-2b with the University of Arizona’s 61″ (1.55 m) Kuiper Telescope and Mont4k CCD in the Bessel U and Harris B photometric passbands to measure its Rayleigh scattering slope to place upper limits on the pressure-dependent radius at, e.g., 10 bar. Such measurements are needed to constrain its derived molecular abundances from primary transit observations. We have also been monitoring XO-2N since the 2013–2014 winter season with Tennessee State University’s Celestron-14 (0.36 m) automated imaging telescope to investigate stellar variability, which could affect XO-2b’s transit depth. Our observations indicate that XO-2N is variable, potentially due to cool star spots, with a peak-to-peak amplitude of 0.0049 ± 0.0007 R-mag and a period of 29.89 ± 0.16 days for the 2013–2014 observing season and a peak-to-peak amplitude of 0.0035 ± 0.0007 R-mag and 27.34 ± 0.21 day period for the 2014–2015 observing season. Because of the likely influence of XO-2N’s variability on the derivation of XO-2b’s transit depth, we cannot bin multiple nights of data to decrease our uncertainties, preventing us from constraining its gas abundances. This study demonstrates that long-term monitoring programs of exoplanet host stars are crucial for understanding host star variability.

  13. Measurement of charged-particle event shape variables in $\\sqrt{s}$ = 7 TeV proton-proton interactions with the ATLAS detector

    CERN Document Server

    Aad, Georges; Abbott, Brad; Abdallah, Jalal; Abdel Khalek, Samah; Abdelalim, Ahmed Ali; Abdinov, Ovsat; Aben, Rosemarie; Abi, Babak; Abolins, Maris; AbouZeid, Ossama; Abramowicz, Halina; Abreu, Henso; Acerbi, Emilio; Acharya, Bobby Samir; Adamczyk, Leszek; Adams, David; Addy, Tetteh; Adelman, Jahred; Adomeit, Stefanie; Adragna, Paolo; Adye, Tim; Aefsky, Scott; Aguilar-Saavedra, Juan Antonio; Agustoni, Marco; Aharrouche, Mohamed; Ahlen, Steven; Ahles, Florian; Ahmad, Ashfaq; Ahsan, Mahsana; Aielli, Giulio; Akdogan, Taylan; Åkesson, Torsten Paul Ake; Akimoto, Ginga; Akimov, Andrei; Alam, Mohammad; Alam, Muhammad Aftab; Albert, Justin; Albrand, Solveig; Aleksa, Martin; Aleksandrov, Igor; Alessandria, Franco; Alexa, Calin; Alexander, Gideon; Alexandre, Gauthier; Alexopoulos, Theodoros; Alhroob, Muhammad; Aliev, Malik; Alimonti, Gianluca; Alison, John; Allbrooke, Benedict; Allport, Phillip; Allwood-Spiers, Sarah; Almond, John; Aloisio, Alberto; Alon, Raz; Alonso, Alejandro; Alonso, Francisco; Alvarez Gonzalez, Barbara; Alviggi, Mariagrazia; Amako, Katsuya; Amelung, Christoph; Ammosov, Vladimir; Amorim, Antonio; Amram, Nir; Anastopoulos, Christos; Ancu, Lucian Stefan; Andari, Nansi; Andeen, Timothy; Anders, Christoph Falk; Anders, Gabriel; Anderson, Kelby; Andreazza, Attilio; Andrei, George Victor; Anduaga, Xabier; Anger, Philipp; Angerami, Aaron; Anghinolfi, Francis; Anisenkov, Alexey; Anjos, Nuno; Annovi, Alberto; Antonaki, Ariadni; Antonelli, Mario; Antonov, Alexey; Antos, Jaroslav; Anulli, Fabio; Aoki, Masato; Aoun, Sahar; Aperio Bella, Ludovica; Apolle, Rudi; Arabidze, Giorgi; Aracena, Ignacio; Arai, Yasuo; Arce, Ayana; Arfaoui, Samir; Arguin, Jean-Francois; Arik, Engin; Arik, Metin; Armbruster, Aaron James; Arnaez, Olivier; Arnal, Vanessa; Arnault, Christian; Artamonov, Andrei; Artoni, Giacomo; Arutinov, David; Asai, Shoji; Asfandiyarov, Ruslan; Ask, Stefan; Åsman, Barbro; Asquith, Lily; Assamagan, Ketevi; Astbury, Alan; Atkinson, Markus; Aubert, Bernard; Auge, Etienne; Augsten, Kamil; Aurousseau, Mathieu; Avolio, Giuseppe; Avramidou, Rachel Maria; Axen, David; Azuelos, Georges; Azuma, Yuya; Baak, Max; Baccaglioni, Giuseppe; Bacci, Cesare; Bach, Andre; Bachacou, Henri; Bachas, Konstantinos; Backes, Moritz; Backhaus, Malte; Badescu, Elisabeta; Bagnaia, Paolo; Bahinipati, Seema; Bai, Yu; Bailey, David; Bain, Travis; Baines, John; Baker, Oliver Keith; Baker, Mark; Baker, Sarah; Banas, Elzbieta; Banerjee, Piyali; Banerjee, Swagato; Banfi, Danilo; Bangert, Andrea Michelle; Bansal, Vikas; Bansil, Hardeep Singh; Barak, Liron; Baranov, Sergei; Barbaro Galtieri, Angela; Barber, Tom; Barberio, Elisabetta Luigia; Barberis, Dario; Barbero, Marlon; Bardin, Dmitri; Barillari, Teresa; Barisonzi, Marcello; Barklow, Timothy; Barlow, Nick; Barnett, Bruce; Barnett, Michael; Baroncelli, Antonio; Barone, Gaetano; Barr, Alan; Barreiro, Fernando; Barreiro Guimarães da Costa, João; Barrillon, Pierre; Bartoldus, Rainer; Barton, Adam Edward; Bartsch, Valeria; Basye, Austin; Bates, Richard; Batkova, Lucia; Batley, Richard; Battaglia, Andreas; Battistin, Michele; Bauer, Florian; Bawa, Harinder Singh; Beale, Steven; Beau, Tristan; Beauchemin, Pierre-Hugues; Beccherle, Roberto; Bechtle, Philip; Beck, Hans Peter; Becker, Anne Kathrin; Becker, Sebastian; Beckingham, Matthew; Becks, Karl-Heinz; Beddall, Andrew; Beddall, Ayda; Bedikian, Sourpouhi; Bednyakov, Vadim; Bee, Christopher; Beemster, Lars; Begel, Michael; Behar Harpaz, Silvia; Beimforde, Michael; Belanger-Champagne, Camille; Bell, Paul; Bell, William; Bella, Gideon; Bellagamba, Lorenzo; Bellina, Francesco; Bellomo, Massimiliano; Belloni, Alberto; Beloborodova, Olga; Belotskiy, Konstantin; Beltramello, Olga; Benary, Odette; Benchekroun, Driss; Bendtz, Katarina; Benekos, Nektarios; Benhammou, Yan; Benhar Noccioli, Eleonora; Benitez Garcia, Jorge-Armando; Benjamin, Douglas; Benoit, Mathieu; Bensinger, James; Benslama, Kamal; Bentvelsen, Stan; Berge, David; Bergeaas Kuutmann, Elin; Berger, Nicolas; Berghaus, Frank; Berglund, Elina; Beringer, Jürg; Bernat, Pauline; Bernhard, Ralf; Bernius, Catrin; Berry, Tracey; Bertella, Claudia; Bertin, Antonio; Bertolucci, Federico; Besana, Maria Ilaria; Besjes, Geert-Jan; Besson, Nathalie; Bethke, Siegfried; Bhimji, Wahid; Bianchi, Riccardo-Maria; Bianco, Michele; Biebel, Otmar; Bieniek, Stephen Paul; Bierwagen, Katharina; Biesiada, Jed; Biglietti, Michela; Bilokon, Halina; Bindi, Marcello; Binet, Sebastien; Bingul, Ahmet; Bini, Cesare; Biscarat, Catherine; Black, Kevin; Blair, Robert; Blanchard, Jean-Baptiste; Blanchot, Georges; Blazek, Tomas; Blocker, Craig; Blocki, Jacek; Blondel, Alain; Blum, Walter; Blumenschein, Ulrike; Bobbink, Gerjan; Bobrovnikov, Victor; Bocchetta, Simona Serena; Bocci, Andrea; Boddy, Christopher Richard; Boehler, Michael; Boek, Jennifer; Boelaert, Nele; Bogaerts, Joannes Andreas; Bogdanchikov, Alexander; Bogouch, Andrei; Bohm, Christian; Bohm, Jan; Boisvert, Veronique; Bold, Tomasz; Boldea, Venera; Bolnet, Nayanka Myriam; Bomben, Marco; Bona, Marcella; Boonekamp, Maarten; Booth, Chris; Bordoni, Stefania; Borer, Claudia; Borisov, Anatoly; Borissov, Guennadi; Borjanovic, Iris; Borri, Marcello; Borroni, Sara; Bortolotto, Valerio; Bos, Kors; Boscherini, Davide; Bosman, Martine; Boterenbrood, Hendrik; Bouchami, Jihene; Boudreau, Joseph; Bouhova-Thacker, Evelina Vassileva; Boumediene, Djamel Eddine; Bourdarios, Claire; Bousson, Nicolas; Boveia, Antonio; Boyd, James; Boyko, Igor; Bozovic-Jelisavcic, Ivanka; Bracinik, Juraj; Branchini, Paolo; Brandt, Andrew; Brandt, Gerhard; Brandt, Oleg; Bratzler, Uwe; Brau, Benjamin; Brau, James; Braun, Helmut; Brazzale, Simone Federico; Brelier, Bertrand; Bremer, Johan; Brendlinger, Kurt; Brenner, Richard; Bressler, Shikma; Britton, Dave; Brochu, Frederic; Brock, Ian; Brock, Raymond; Broggi, Francesco; Bromberg, Carl; Bronner, Johanna; Brooijmans, Gustaaf; Brooks, Timothy; Brooks, William; Brown, Gareth; Brown, Heather; Bruckman de Renstrom, Pawel; Bruncko, Dusan; Bruneliere, Renaud; Brunet, Sylvie; Bruni, Alessia; Bruni, Graziano; Bruschi, Marco; Buanes, Trygve; Buat, Quentin; Bucci, Francesca; Buchanan, James; Buchholz, Peter; Buckingham, Ryan; Buckley, Andrew; Buda, Stelian Ioan; Budagov, Ioulian; Budick, Burton; Büscher, Volker; Bugge, Lars; Bulekov, Oleg; Bundock, Aaron Colin; Bunse, Moritz; Buran, Torleiv; Burckhart, Helfried; Burdin, Sergey; Burgess, Thomas; Burke, Stephen; Busato, Emmanuel; Bussey, Peter; Buszello, Claus-Peter; Butler, Bart; Butler, John; Buttar, Craig; Butterworth, Jonathan; Buttinger, William; Cabrera Urbán, Susana; Caforio, Davide; Cakir, Orhan; Calafiura, Paolo; Calderini, Giovanni; Calfayan, Philippe; Calkins, Robert; Caloba, Luiz; Caloi, Rita; Calvet, David; Calvet, Samuel; Camacho Toro, Reina; Camarri, Paolo; Cameron, David; Caminada, Lea Michaela; Caminal Armadans, Roger; Campana, Simone; Campanelli, Mario; Canale, Vincenzo; Canelli, Florencia; Canepa, Anadi; Cantero, Josu; Cantrill, Robert; Capasso, Luciano; Capeans Garrido, Maria Del Mar; Caprini, Irinel; Caprini, Mihai; Capriotti, Daniele; Capua, Marcella; Caputo, Regina; Cardarelli, Roberto; Carli, Tancredi; Carlino, Gianpaolo; Carminati, Leonardo; Caron, Bryan; Caron, Sascha; Carquin, Edson; Carrillo Montoya, German D; Carter, Antony; Carter, Janet; Carvalho, João; Casadei, Diego; Casado, Maria Pilar; Cascella, Michele; Caso, Carlo; Castaneda Hernandez, Alfredo Martin; Castaneda-Miranda, Elizabeth; Castillo Gimenez, Victoria; Castro, Nuno Filipe; Cataldi, Gabriella; Catastini, Pierluigi; Catinaccio, Andrea; Catmore, James; Cattai, Ariella; Cattani, Giordano; Caughron, Seth; Cavaliere, Viviana; Cavalleri, Pietro; Cavalli, Donatella; Cavalli-Sforza, Matteo; Cavasinni, Vincenzo; Ceradini, Filippo; Santiago Cerqueira, Augusto; Cerri, Alessandro; Cerrito, Lucio; Cerutti, Fabio; Cetin, Serkant Ali; Chafaq, Aziz; Chakraborty, Dhiman; Chalupkova, Ina; Chan, Kevin; Chang, Philip; Chapleau, Bertrand; Chapman, John Derek; Chapman, John Wehrley; Chareyre, Eve; Charlton, Dave; Chavda, Vikash; Chavez Barajas, Carlos Alberto; Cheatham, Susan; Chekanov, Sergei; Chekulaev, Sergey; Chelkov, Gueorgui; Chelstowska, Magda Anna; Chen, Chunhui; Chen, Hucheng; Chen, Shenjian; Chen, Xin; Chen, Yujiao; Cheplakov, Alexander; Cherkaoui El Moursli, Rajaa; Chernyatin, Valeriy; Cheu, Elliott; Cheung, Sing-Leung; Chevalier, Laurent; Chiefari, Giovanni; Chikovani, Leila; Childers, John Taylor; Chilingarov, Alexandre; Chiodini, Gabriele; Chisholm, Andrew; Chislett, Rebecca Thalatta; Chitan, Adrian; Chizhov, Mihail; Choudalakis, Georgios; Chouridou, Sofia; Christidi, Illectra-Athanasia; Christov, Asen; Chromek-Burckhart, Doris; Chu, Ming-Lee; Chudoba, Jiri; Ciapetti, Guido; Ciftci, Abbas Kenan; Ciftci, Rena; Cinca, Diane; Cindro, Vladimir; Ciocca, Claudia; Ciocio, Alessandra; Cirilli, Manuela; Cirkovic, Predrag; Citterio, Mauro; Ciubancan, Mihai; Clark, Allan G; Clark, Philip James; Clarke, Robert; Cleland, Bill; Clemens, Jean-Claude; Clement, Benoit; Clement, Christophe; Coadou, Yann; Cobal, Marina; Coccaro, Andrea; Cochran, James H; Cogan, Joshua Godfrey; Coggeshall, James; Cogneras, Eric; Colas, Jacques; Cole, Stephen; Colijn, Auke-Pieter; Collins, Neil; Collins-Tooth, Christopher; Collot, Johann; Colombo, Tommaso; Colon, German; Conde Muiño, Patricia; Coniavitis, Elias; Conidi, Maria Chiara; Consonni, Sofia Maria; Consorti, Valerio; Constantinescu, Serban; Conta, Claudio; Conti, Geraldine; Conventi, Francesco; Cooke, Mark; Cooper, Ben; Cooper-Sarkar, Amanda; Copic, Katherine; Cornelissen, Thijs; Corradi, Massimo; Corriveau, Francois; Cortes-Gonzalez, Arely; Cortiana, Giorgio; Costa, Giuseppe; Costa, María José; Costanzo, Davide; Côté, David; Courneyea, Lorraine; Cowan, Glen; Cowden, Christopher; Cox, Brian; Cranmer, Kyle; Crescioli, Francesco; Cristinziani, Markus; Crosetti, Giovanni; Crépé-Renaudin, Sabine; Cuciuc, Constantin-Mihai; Cuenca Almenar, Cristóbal; Cuhadar Donszelmann, Tulay; Curatolo, Maria; Curtis, Chris; Cuthbert, Cameron; Cwetanski, Peter; Czirr, Hendrik; Czodrowski, Patrick; Czyczula, Zofia; D'Auria, Saverio; D'Onofrio, Monica; D'Orazio, Alessia; Da Cunha Sargedas De Sousa, Mario Jose; Da Via, Cinzia; Dabrowski, Wladyslaw; Dafinca, Alexandru; Dai, Tiesheng; Dallapiccola, Carlo; Dam, Mogens; Dameri, Mauro; Damiani, Daniel; Danielsson, Hans Olof; Dao, Valerio; Darbo, Giovanni; Darlea, Georgiana Lavinia; Dassoulas, James; Davey, Will; Davidek, Tomas; Davidson, Nadia; Davidson, Ruth; Davies, Eleanor; Davies, Merlin; Davignon, Olivier; Davison, Adam; Davygora, Yuriy; Dawe, Edmund; Dawson, Ian; Daya-Ishmukhametova, Rozmin; De, Kaushik; de Asmundis, Riccardo; De Castro, Stefano; De Cecco, Sandro; de Graat, Julien; De Groot, Nicolo; de Jong, Paul; De La Taille, Christophe; De la Torre, Hector; De Lorenzi, Francesco; de Mora, Lee; De Nooij, Lucie; De Pedis, Daniele; De Salvo, Alessandro; De Sanctis, Umberto; De Santo, Antonella; De Vivie De Regie, Jean-Baptiste; De Zorzi, Guido; Dearnaley, William James; Debbe, Ramiro; Debenedetti, Chiara; Dechenaux, Benjamin; Dedovich, Dmitri; Degenhardt, James; Del Papa, Carlo; Del Peso, Jose; Del Prete, Tarcisio; Delemontex, Thomas; Deliyergiyev, Maksym; Dell'Acqua, Andrea; Dell'Asta, Lidia; Della Pietra, Massimo; della Volpe, Domenico; Delmastro, Marco; Delsart, Pierre-Antoine; Deluca, Carolina; Demers, Sarah; Demichev, Mikhail; Demirkoz, Bilge; Deng, Jianrong; Denisov, Sergey; Derendarz, Dominik; Derkaoui, Jamal Eddine; Derue, Frederic; Dervan, Paul; Desch, Klaus Kurt; Devetak, Erik; Deviveiros, Pier-Olivier; Dewhurst, Alastair; DeWilde, Burton; Dhaliwal, Saminder; Dhullipudi, Ramasudhakar; Di Ciaccio, Anna; Di Ciaccio, Lucia; Di Girolamo, Alessandro; Di Girolamo, Beniamino; Di Luise, Silvestro; Di Mattia, Alessandro; Di Micco, Biagio; Di Nardo, Roberto; Di Simone, Andrea; Di Sipio, Riccardo; Diaz, Marco Aurelio; Diehl, Edward; Dietrich, Janet; Dietzsch, Thorsten; Diglio, Sara; Dindar Yagci, Kamile; Dingfelder, Jochen; Dinut, Florin; Dionisi, Carlo; Dita, Petre; Dita, Sanda; Dittus, Fridolin; Djama, Fares; Djobava, Tamar; Barros do Vale, Maria Aline; Do Valle Wemans, André; Doan, Thi Kieu Oanh; Dobbs, Matt; Dobinson, Robert; Dobos, Daniel; Dobson, Ellie; Dodd, Jeremy; Doglioni, Caterina; Doherty, Tom; Doi, Yoshikuni; Dolejsi, Jiri; Dolenc, Irena; Dolezal, Zdenek; Dolgoshein, Boris; Dohmae, Takeshi; Donadelli, Marisilvia; Donini, Julien; Dopke, Jens; Doria, Alessandra; Dos Anjos, Andre; Dotti, Andrea; Dova, Maria-Teresa; Doxiadis, Alexander; Doyle, Tony; Dris, Manolis; Dubbert, Jörg; Dube, Sourabh; Duchovni, Ehud; Duckeck, Guenter; Duda, Dominik; Dudarev, Alexey; Dudziak, Fanny; Dührssen, Michael; Duerdoth, Ian; Duflot, Laurent; Dufour, Marc-Andre; Duguid, Liam; Dunford, Monica; Duran Yildiz, Hatice; Duxfield, Robert; Dwuznik, Michal; Dydak, Friedrich; Düren, Michael; Ebke, Johannes; Eckweiler, Sebastian; Edmonds, Keith; Edson, William; Edwards, Clive; Edwards, Nicholas Charles; Ehrenfeld, Wolfgang; Eifert, Till; Eigen, Gerald; Einsweiler, Kevin; Eisenhandler, Eric; Ekelof, Tord; El Kacimi, Mohamed; Ellert, Mattias; Elles, Sabine; Ellinghaus, Frank; Ellis, Katherine; Ellis, Nicolas; Elmsheuser, Johannes; Elsing, Markus; Emeliyanov, Dmitry; Engelmann, Roderich; Engl, Albert; Epp, Brigitte; Erdmann, Johannes; Ereditato, Antonio; Eriksson, Daniel; Ernst, Jesse; Ernst, Michael; Ernwein, Jean; Errede, Deborah; Errede, Steven; Ertel, Eugen; Escalier, Marc; Esch, Hendrik; Escobar, Carlos; Espinal Curull, Xavier; Esposito, Bellisario; Etienne, Francois; Etienvre, Anne-Isabelle; Etzion, Erez; Evangelakou, Despoina; Evans, Hal; Fabbri, Laura; Fabre, Caroline; Fakhrutdinov, Rinat; Falciano, Speranza; Fang, Yaquan; Fanti, Marcello; Farbin, Amir; Farilla, Addolorata; Farley, Jason; Farooque, Trisha; Farrell, Steven; Farrington, Sinead; Farthouat, Philippe; Fassi, Farida; Fassnacht, Patrick; Fassouliotis, Dimitrios; Fatholahzadeh, Baharak; Favareto, Andrea; Fayard, Louis; Fazio, Salvatore; Febbraro, Renato; Federic, Pavol; Fedin, Oleg; Fedorko, Wojciech; Fehling-Kaschek, Mirjam; Feligioni, Lorenzo; Fellmann, Denis; Feng, Cunfeng; Feng, Eric; Fenyuk, Alexander; Ferencei, Jozef; Fernando, Waruna; Ferrag, Samir; Ferrando, James; Ferrara, Valentina; Ferrari, Arnaud; Ferrari, Pamela; Ferrari, Roberto; Ferreira de Lima, Danilo Enoque; Ferrer, Antonio; Ferrere, Didier; Ferretti, Claudio; Ferretto Parodi, Andrea; Fiascaris, Maria; Fiedler, Frank; Filipčič, Andrej; Filthaut, Frank; Fincke-Keeler, Margret; Fiolhais, Miguel; Fiorini, Luca; Firan, Ana; Fischer, Gordon; Fisher, Matthew; Flechl, Martin; Fleck, Ivor; Fleckner, Johanna; Fleischmann, Philipp; Fleischmann, Sebastian; Flick, Tobias; Floderus, Anders; Flores Castillo, Luis; Flowerdew, Michael; Fonseca Martin, Teresa; Formica, Andrea; Forti, Alessandra; Fortin, Dominique; Fournier, Daniel; Fox, Harald; Francavilla, Paolo; Franchini, Matteo; Franchino, Silvia; Francis, David; Frank, Tal; Franz, Sebastien; Fraternali, Marco; Fratina, Sasa; French, Sky; Friedrich, Conrad; Friedrich, Felix; Froeschl, Robert; Froidevaux, Daniel; Frost, James; Fukunaga, Chikara; Fullana Torregrosa, Esteban; Fulsom, Bryan Gregory; Fuster, Juan; Gabaldon, Carolina; Gabizon, Ofir; Gadfort, Thomas; Gadomski, Szymon; Gagliardi, Guido; Gagnon, Pauline; Galea, Cristina; Gallas, Elizabeth; Gallo, Valentina Santina; Gallop, Bruce; Gallus, Petr; Gan, KK; Gao, Yongsheng; Gaponenko, Andrei; Garberson, Ford; Garcia-Sciveres, Maurice; García, Carmen; García Navarro, José Enrique; Gardner, Robert; Garelli, Nicoletta; Garitaonandia, Hegoi; Garonne, Vincent; Gatti, Claudio; Gaudio, Gabriella; Gaur, Bakul; Gauthier, Lea; Gauzzi, Paolo; Gavrilenko, Igor; Gay, Colin; Gaycken, Goetz; Gazis, Evangelos; Ge, Peng; Gecse, Zoltan; Gee, Norman; Geerts, Daniël Alphonsus Adrianus; Geich-Gimbel, Christoph; Gellerstedt, Karl; Gemme, Claudia; Gemmell, Alistair; Genest, Marie-Hélène; Gentile, Simonetta; George, Matthias; George, Simon; Gerlach, Peter; Gershon, Avi; Geweniger, Christoph; Ghazlane, Hamid; Ghodbane, Nabil; Giacobbe, Benedetto; Giagu, Stefano; Giakoumopoulou, Victoria; Giangiobbe, Vincent; Gianotti, Fabiola; Gibbard, Bruce; Gibson, Adam; Gibson, Stephen; Gillberg, Dag; Gillman, Tony; Gingrich, Douglas; Ginzburg, Jonatan; Giokaris, Nikos; Giordani, MarioPaolo; Giordano, Raffaele; Giorgi, Francesco Michelangelo; Giovannini, Paola; Giraud, Pierre-Francois; Giugni, Danilo; Giunta, Michele; Giusti, Paolo; Gjelsten, Børge Kile; Gladilin, Leonid; Glasman, Claudia; Glatzer, Julian; Glazov, Alexandre; Glitza, Karl-Walter; Glonti, George; Goddard, Jack Robert; Godfrey, Jennifer; Godlewski, Jan; Goebel, Martin; Göpfert, Thomas; Goeringer, Christian; Gössling, Claus; Goldfarb, Steven; Golling, Tobias; Gomes, Agostinho; Gomez Fajardo, Luz Stella; Gonçalo, Ricardo; Goncalves Pinto Firmino Da Costa, Joao; Gonella, Laura; Gonzalez, Saul; González de la Hoz, Santiago; Gonzalez Parra, Garoe; Gonzalez Silva, Laura; Gonzalez-Sevilla, Sergio; Goodson, Jeremiah Jet; Goossens, Luc; Gorbounov, Petr Andreevich; Gordon, Howard; Gorelov, Igor; Gorfine, Grant; Gorini, Benedetto; Gorini, Edoardo; Gorišek, Andrej; Gornicki, Edward; Gosdzik, Bjoern; Goshaw, Alfred; Gosselink, Martijn; Gostkin, Mikhail Ivanovitch; Gough Eschrich, Ivo; Gouighri, Mohamed; Goujdami, Driss; Goulette, Marc Phillippe; Goussiou, Anna; Goy, Corinne; Gozpinar, Serdar; Grabowska-Bold, Iwona; Grafström, Per; Grahn, Karl-Johan; Grancagnolo, Francesco; Grancagnolo, Sergio; Grassi, Valerio; Gratchev, Vadim; Grau, Nathan; Gray, Heather; Gray, Julia Ann; Graziani, Enrico; Grebenyuk, Oleg; Greenshaw, Timothy; Greenwood, Zeno Dixon; Gregersen, Kristian; Gregor, Ingrid-Maria; Grenier, Philippe; Griffiths, Justin; Grigalashvili, Nugzar; Grillo, Alexander; Grinstein, Sebastian; Gris, Philippe Luc Yves; Grishkevich, Yaroslav; Grivaz, Jean-Francois; Gross, Eilam; Grosse-Knetter, Joern; Groth-Jensen, Jacob; Grybel, Kai; Guest, Daniel; Guicheney, Christophe; Guindon, Stefan; Gul, Umar; Guler, Hulya; Gunther, Jaroslav; Guo, Bin; Guo, Jun; Gutierrez, Phillip; Guttman, Nir; Gutzwiller, Olivier; Guyot, Claude; Gwenlan, Claire; Gwilliam, Carl; Haas, Andy; Haas, Stefan; Haber, Carl; Hadavand, Haleh Khani; Hadley, David; Haefner, Petra; Hahn, Ferdinand; Haider, Stefan; Hajduk, Zbigniew; Hakobyan, Hrachya; Hall, David; Haller, Johannes; Hamacher, Klaus; Hamal, Petr; Hamer, Matthias; Hamilton, Andrew; Hamilton, Samuel; Han, Liang; Hanagaki, Kazunori; Hanawa, Keita; Hance, Michael; Handel, Carsten; Hanke, Paul; Hansen, John Renner; Hansen, Jørgen Beck; Hansen, Jorn Dines; Hansen, Peter Henrik; Hansson, Per; Hara, Kazuhiko; Hare, Gabriel; Harenberg, Torsten; Harkusha, Siarhei; Harper, Devin; Harrington, Robert; Harris, Orin; Hartert, Jochen; Hartjes, Fred; Haruyama, Tomiyoshi; Harvey, Alex; Hasegawa, Satoshi; Hasegawa, Yoji; Hassani, Samira; Haug, Sigve; Hauschild, Michael; Hauser, Reiner; Havranek, Miroslav; Hawkes, Christopher; Hawkings, Richard John; Hawkins, Anthony David; Hawkins, Donovan; Hayakawa, Takashi; Hayashi, Takayasu; Hayden, Daniel; Hays, Chris; Hayward, Helen; Haywood, Stephen; He, Mao; Head, Simon; Hedberg, Vincent; Heelan, Louise; Heim, Sarah; Heinemann, Beate; Heisterkamp, Simon; Helary, Louis; Heller, Claudio; Heller, Matthieu; Hellman, Sten; Hellmich, Dennis; Helsens, Clement; Henderson, Robert; Henke, Michael; Henrichs, Anna; Henriques Correia, Ana Maria; Henrot-Versille, Sophie; Hensel, Carsten; Henß, Tobias; Medina Hernandez, Carlos; Hernández Jiménez, Yesenia; Herrberg, Ruth; Herten, Gregor; Hertenberger, Ralf; Hervas, Luis; Hesketh, Gavin Grant; Hessey, Nigel; Higón-Rodriguez, Emilio; Hill, John; Hiller, Karl Heinz; Hillert, Sonja; Hillier, Stephen; Hinchliffe, Ian; Hines, Elizabeth; Hirose, Minoru; Hirsch, Florian; Hirschbuehl, Dominic; Hobbs, John; Hod, Noam; Hodgkinson, Mark; Hodgson, Paul; Hoecker, Andreas; Hoeferkamp, Martin; Hoffman, Julia; Hoffmann, Dirk; Hohlfeld, Marc; Holder, Martin; Holmgren, Sven-Olof; Holy, Tomas; Holzbauer, Jenny; Hong, Tae Min; Hooft van Huysduynen, Loek; Horner, Stephan; Hostachy, Jean-Yves; Hou, Suen; Hoummada, Abdeslam; Howard, Jacob; Howarth, James; Hristova, Ivana; Hrivnac, Julius; Hryn'ova, Tetiana; Hsu, Pai-hsien Jennifer; Hsu, Shih-Chieh; Hu, Diedi; Hubacek, Zdenek; Hubaut, Fabrice; Huegging, Fabian; Huelsing, Tobias Alexander; Huettmann, Antje; Huffman, Todd Brian; Hughes, Emlyn; Hughes, Gareth; Huhtinen, Mika; Hurwitz, Martina; Husemann, Ulrich; Huseynov, Nazim; Huston, Joey; Huth, John; Iacobucci, Giuseppe; Iakovidis, Georgios; Ibbotson, Michael; Ibragimov, Iskander; Iconomidou-Fayard, Lydia; Idarraga, John; Iengo, Paolo; Igonkina, Olga; Ikegami, Yoichi; Ikeno, Masahiro; Iliadis, Dimitrios; Ilic, Nikolina; Ince, Tayfun; Inigo-Golfin, Joaquin; Ioannou, Pavlos; Iodice, Mauro; Iordanidou, Kalliopi; Ippolito, Valerio; Irles Quiles, Adrian; Isaksson, Charlie; Ishino, Masaya; Ishitsuka, Masaki; Ishmukhametov, Renat; Issever, Cigdem; Istin, Serhat; Ivashin, Anton; Iwanski, Wieslaw; Iwasaki, Hiroyuki; Izen, Joseph; Izzo, Vincenzo; Jackson, Brett; Jackson, John; Jackson, Paul; Jaekel, Martin; Jain, Vivek; Jakobs, Karl; Jakobsen, Sune; Jakoubek, Tomas; Jakubek, Jan; Jana, Dilip; Jansen, Eric; Jansen, Hendrik; Jantsch, Andreas; Janus, Michel; Jarlskog, Göran; Jeanty, Laura; Jen-La Plante, Imai; Jennens, David; Jenni, Peter; Loevschall-Jensen, Ask Emil; Jež, Pavel; Jézéquel, Stéphane; Jha, Manoj Kumar; Ji, Haoshuang; Ji, Weina; Jia, Jiangyong; Jiang, Yi; Jimenez Belenguer, Marcos; Jin, Shan; Jinnouchi, Osamu; Joergensen, Morten Dam; Joffe, David; Johansen, Marianne; Johansson, Erik; Johansson, Per; Johnert, Sebastian; Johns, Kenneth; Jon-And, Kerstin; Jones, Graham; Jones, Roger; Jones, Tim; Joram, Christian; Jorge, Pedro; Joshi, Kiran Daniel; Jovicevic, Jelena; Jovin, Tatjana; Ju, Xiangyang; Jung, Christian; Jungst, Ralph Markus; Juranek, Vojtech; Jussel, Patrick; Juste Rozas, Aurelio; Kabana, Sonja; Kaci, Mohammed; Kaczmarska, Anna; Kadlecik, Peter; Kado, Marumi; Kagan, Harris; Kagan, Michael; Kajomovitz, Enrique; Kalinin, Sergey; Kalinovskaya, Lidia; Kama, Sami; Kanaya, Naoko; Kaneda, Michiru; Kaneti, Steven; Kanno, Takayuki; Kantserov, Vadim; Kanzaki, Junichi; Kaplan, Benjamin; Kapliy, Anton; Kaplon, Jan; Kar, Deepak; Karagounis, Michael; Karakostas, Konstantinos; Karnevskiy, Mikhail; Kartvelishvili, Vakhtang; Karyukhin, Andrey; Kashif, Lashkar; Kasieczka, Gregor; Kass, Richard; Kastanas, Alex; Kataoka, Mayuko; Kataoka, Yousuke; Katsoufis, Elias; Katzy, Judith; Kaushik, Venkatesh; Kawagoe, Kiyotomo; Kawamoto, Tatsuo; Kawamura, Gen; Kayl, Manuel; Kazama, Shingo; Kazanin, Vassili; Kazarinov, Makhail; Keeler, Richard; Kehoe, Robert; Keil, Markus; Kekelidze, George; Keller, John; Kenyon, Mike; Kepka, Oldrich; Kerschen, Nicolas; Kerševan, Borut Paul; Kersten, Susanne; Kessoku, Kohei; Keung, Justin; Khalil-zada, Farkhad; Khandanyan, Hovhannes; Khanov, Alexander; Kharchenko, Dmitri; Khodinov, Alexander; Khomich, Andrei; Khoo, Teng Jian; Khoriauli, Gia; Khoroshilov, Andrey; Khovanskiy, Valery; Khramov, Evgeniy; Khubua, Jemal; Kim, Hyeon Jin; Kim, Shinhong; Kimura, Naoki; Kind, Oliver; King, Barry; King, Matthew; King, Robert Steven Beaufoy; Kirk, Julie; Kiryunin, Andrey; Kishimoto, Tomoe; Kisielewska, Danuta; Kitamura, Takumi; Kittelmann, Thomas; Kiuchi, Kenji; Kladiva, Eduard; Klein, Max; Klein, Uta; Kleinknecht, Konrad; Klemetti, Miika; Klier, Amit; Klimek, Pawel; Klimentov, Alexei; Klingenberg, Reiner; Klinger, Joel Alexander; Klinkby, Esben; Klioutchnikova, Tatiana; Klok, Peter; Klous, Sander; Kluge, Eike-Erik; Kluge, Thomas; Kluit, Peter; Kluth, Stefan; Knecht, Neil; Kneringer, Emmerich; Knoops, Edith; Knue, Andrea; Ko, Byeong Rok; Kobayashi, Tomio; Kobel, Michael; Kocian, Martin; Kodys, Peter; Köneke, Karsten; König, Adriaan; Koenig, Sebastian; Köpke, Lutz; Koetsveld, Folkert; Koevesarki, Peter; Koffas, Thomas; Koffeman, Els; Kogan, Lucy Anne; Kohlmann, Simon; Kohn, Fabian; Kohout, Zdenek; Kohriki, Takashi; Koi, Tatsumi; Kolachev, Guennady; Kolanoski, Hermann; Kolesnikov, Vladimir; Koletsou, Iro; Koll, James; Kollefrath, Michael; Komar, Aston; Komori, Yuto; Kondo, Takahiko; Kono, Takanori; Kononov, Anatoly; Konoplich, Rostislav; Konstantinidis, Nikolaos; Koperny, Stefan; Korcyl, Krzysztof; Kordas, Kostantinos; Korn, Andreas; Korol, Aleksandr; Korolkov, Ilya; Korolkova, Elena; Korotkov, Vladislav; Kortner, Oliver; Kortner, Sandra; Kostyukhin, Vadim; Kotov, Sergey; Kotov, Vladislav; Kotwal, Ashutosh; Kourkoumelis, Christine; Kouskoura, Vasiliki; Koutsman, Alex; Kowalewski, Robert Victor; Kowalski, Tadeusz; Kozanecki, Witold; Kozhin, Anatoly; Kral, Vlastimil; Kramarenko, Viktor; Kramberger, Gregor; Krasny, Mieczyslaw Witold; Krasznahorkay, Attila; Kraus, Jana; Kreiss, Sven; Krejci, Frantisek; Kretzschmar, Jan; Krieger, Nina; Krieger, Peter; Kroeninger, Kevin; Kroha, Hubert; Kroll, Joe; Kroseberg, Juergen; Krstic, Jelena; Kruchonak, Uladzimir; Krüger, Hans; Kruker, Tobias; Krumnack, Nils; Krumshteyn, Zinovii; Kubota, Takashi; Kuday, Sinan; Kuehn, Susanne; Kugel, Andreas; Kuhl, Thorsten; Kuhn, Dietmar; Kukhtin, Victor; Kulchitsky, Yuri; Kuleshov, Sergey; Kummer, Christian; Kuna, Marine; Kunkle, Joshua; Kupco, Alexander; Kurashige, Hisaya; Kurata, Masakazu; Kurochkin, Yurii; Kus, Vlastimil; Kuwertz, Emma Sian; Kuze, Masahiro; Kvita, Jiri; Kwee, Regina; La Rosa, Alessandro; La Rotonda, Laura; Labarga, Luis; Labbe, Julien; Lablak, Said; Lacasta, Carlos; Lacava, Francesco; Lacker, Heiko; Lacour, Didier; Lacuesta, Vicente Ramón; Ladygin, Evgueni; Lafaye, Remi; Laforge, Bertrand; Lagouri, Theodota; Lai, Stanley; Laisne, Emmanuel; Lamanna, Massimo; Lambourne, Luke; Lampen, Caleb; Lampl, Walter; Lancon, Eric; Landgraf, Ulrich; Landon, Murrough; Lane, Jenna; Lang, Valerie Susanne; Lange, Clemens; Lankford, Andrew; Lanni, Francesco; Lantzsch, Kerstin; Laplace, Sandrine; Lapoire, Cecile; Laporte, Jean-Francois; Lari, Tommaso; Larner, Aimee; Lassnig, Mario; Laurelli, Paolo; Lavorini, Vincenzo; Lavrijsen, Wim; Laycock, Paul; Le Dortz, Olivier; Le Guirriec, Emmanuel; Le Maner, Christophe; Le Menedeu, Eve; LeCompte, Thomas; Ledroit-Guillon, Fabienne Agnes Marie; Lee, Hurng-Chun; Lee, Jason; Lee, Shih-Chang; Lee, Lawrence; Lefebvre, Michel; Legendre, Marie; Legger, Federica; Leggett, Charles; Lehmacher, Marc; Lehmann Miotto, Giovanna; Lei, Xiaowen; Leite, Marco Aurelio Lisboa; Leitner, Rupert; Lellouch, Daniel; Lemmer, Boris; Lendermann, Victor; Leney, Katharine; Lenz, Tatiana; Lenzen, Georg; Lenzi, Bruno; Leonhardt, Kathrin; Leontsinis, Stefanos; Lepold, Florian; Leroy, Claude; Lessard, Jean-Raphael; Lester, Christopher; Lester, Christopher Michael; Levêque, Jessica; Levin, Daniel; Levinson, Lorne; Lewis, Adrian; Lewis, George; Leyko, Agnieszka; Leyton, Michael; Li, Bo; Li, Haifeng; Li, Shu; Li, Xuefei; Liang, Zhijun; Liao, Hongbo; Liberti, Barbara; Lichard, Peter; Lichtnecker, Markus; Lie, Ki; Liebig, Wolfgang; Limbach, Christian; Limosani, Antonio; Limper, Maaike; Lin, Simon; Linde, Frank; Linnemann, James; Lipeles, Elliot; Lipniacka, Anna; Liss, Tony; Lissauer, David; Lister, Alison; Litke, Alan; Liu, Chuanlei; Liu, Dong; Liu, Hao; Liu, Jianbei; Liu, Lulu; Liu, Minghui; Liu, Yanwen; Livan, Michele; Livermore, Sarah; Lleres, Annick; Llorente Merino, Javier; Lloyd, Stephen; Lobodzinska, Ewelina; Loch, Peter; Lockman, William; Loddenkoetter, Thomas; Loebinger, Fred; Loginov, Andrey; Loh, Chang Wei; Lohse, Thomas; Lohwasser, Kristin; Lokajicek, Milos; Lombardo, Vincenzo Paolo; Long, Robin Eamonn; Lopes, Lourenco; Lopez Mateos, David; Lorenz, Jeanette; Lorenzo Martinez, Narei; Losada, Marta; Loscutoff, Peter; Lo Sterzo, Francesco; Losty, Michael; Lou, Xinchou; Lounis, Abdenour; Loureiro, Karina; Love, Jeremy; Love, Peter; Lowe, Andrew; Lu, Feng; Lubatti, Henry; Luci, Claudio; Lucotte, Arnaud; Ludwig, Andreas; Ludwig, Dörthe; Ludwig, Inga; Ludwig, Jens; Luehring, Frederick; Luijckx, Guy; Lukas, Wolfgang; Lumb, Debra; Luminari, Lamberto; Lund, Esben; Lund-Jensen, Bengt; Lundberg, Björn; Lundberg, Johan; Lundberg, Olof; Lundquist, Johan; Lungwitz, Matthias; Lynn, David; Lytken, Else; Ma, Hong; Ma, Lian Liang; Maccarrone, Giovanni; Macchiolo, Anna; Maček, Boštjan; Machado Miguens, Joana; Mackeprang, Rasmus; Madaras, Ronald; Mader, Wolfgang; Maenner, Reinhard; Maeno, Tadashi; Mättig, Peter; Mättig, Stefan; Magnoni, Luca; Magradze, Erekle; Mahboubi, Kambiz; Mahmoud, Sara; Mahout, Gilles; Maiani, Camilla; Maidantchik, Carmen; Maio, Amélia; Majewski, Stephanie; Makida, Yasuhiro; Makovec, Nikola; Mal, Prolay; Malaescu, Bogdan; Malecki, Pawel; Malecki, Piotr; Maleev, Victor; Malek, Fairouz; Mallik, Usha; Malon, David; Malone, Caitlin; Maltezos, Stavros; Malyshev, Vladimir; Malyukov, Sergei; Mameghani, Raphael; Mamuzic, Judita; Manabe, Atsushi; Mandelli, Luciano; Mandić, Igor; Mandrysch, Rocco; Maneira, José; Mangeard, Pierre-Simon; Manhaes de Andrade Filho, Luciano; Manjarres Ramos, Joany Andreina; Mann, Alexander; Manning, Peter; Manousakis-Katsikakis, Arkadios; Mansoulie, Bruno; Mapelli, Alessandro; Mapelli, Livio; March, Luis; Marchand, Jean-Francois; Marchese, Fabrizio; Marchiori, Giovanni; Marcisovsky, Michal; Marino, Christopher; Marroquim, Fernando; Marshall, Zach; Martens, Kalen; Marti, Lukas Fritz; Marti-Garcia, Salvador; Martin, Brian; Martin, Brian Thomas; Martin, Jean-Pierre; Martin, Tim; Martin, Victoria Jane; Martin dit Latour, Bertrand; Martin-Haugh, Stewart; Martinez, Mario; Martinez Outschoorn, Verena; Martyniuk, Alex; Marx, Marilyn; Marzano, Francesco; Marzin, Antoine; Masetti, Lucia; Mashimo, Tetsuro; Mashinistov, Ruslan; Masik, Jiri; Maslennikov, Alexey; Massa, Ignazio; Massaro, Graziano; Massol, Nicolas; Mastrandrea, Paolo; Mastroberardino, Anna; Masubuchi, Tatsuya; Matricon, Pierre; Matsunaga, Hiroyuki; Matsushita, Takashi; Mattravers, Carly; Maurer, Julien; Maxfield, Stephen; Mayne, Anna; Mazini, Rachid; Mazur, Michael; Mazzaferro, Luca; Mazzanti, Marcello; Mc Donald, Jeffrey; Mc Kee, Shawn Patrick; McCarn, Allison; McCarthy, Robert; McCarthy, Tom; McCubbin, Norman; McFarlane, Kenneth; Mcfayden, Josh; Mchedlidze, Gvantsa; Mclaughlan, Tom; McMahon, Steve; McPherson, Robert; Meade, Andrew; Mechnich, Joerg; Mechtel, Markus; Medinnis, Mike; Meera-Lebbai, Razzak; Meguro, Tatsuma; Mehdiyev, Rashid; Mehlhase, Sascha; Mehta, Andrew; Meier, Karlheinz; Meirose, Bernhard; Melachrinos, Constantinos; Mellado Garcia, Bruce Rafael; Meloni, Federico; Mendoza Navas, Luis; Meng, Zhaoxia; Mengarelli, Alberto; Menke, Sven; Meoni, Evelin; Mercurio, Kevin Michael; Mermod, Philippe; Merola, Leonardo; Meroni, Chiara; Merritt, Frank; Merritt, Hayes; Messina, Andrea; Metcalfe, Jessica; Mete, Alaettin Serhan; Meyer, Carsten; Meyer, Christopher; Meyer, Jean-Pierre; Meyer, Jochen; Meyer, Joerg; Meyer, Thomas Christian; Miao, Jiayuan; Michal, Sebastien; Micu, Liliana; Middleton, Robin; Migas, Sylwia; Mijović, Liza; Mikenberg, Giora; Mikestikova, Marcela; Mikuž, Marko; Miller, David; Miller, Robert; Mills, Bill; Mills, Corrinne; Milov, Alexander; Milstead, David; Milstein, Dmitry; Minaenko, Andrey; Miñano Moya, Mercedes; Minashvili, Irakli; Mincer, Allen; Mindur, Bartosz; Mineev, Mikhail; Ming, Yao; Mir, Lluisa-Maria; Mirabelli, Giovanni; Mitrevski, Jovan; Mitsou, Vasiliki A; Mitsui, Shingo; Miyagawa, Paul; Mjörnmark, Jan-Ulf; Moa, Torbjoern; Moeller, Victoria; Mönig, Klaus; Möser, Nicolas; Mohapatra, Soumya; Mohr, Wolfgang; Moles-Valls, Regina; Monk, James; Monnier, Emmanuel; Montejo Berlingen, Javier; Monticelli, Fernando; Monzani, Simone; Moore, Roger; Moorhead, Gareth; Mora Herrera, Clemencia; Moraes, Arthur; Morange, Nicolas; Morel, Julien; Morello, Gianfranco; Moreno, Deywis; Moreno Llácer, María; Morettini, Paolo; Morgenstern, Marcus; Morii, Masahiro; Morley, Anthony Keith; Mornacchi, Giuseppe; Morris, John; Morvaj, Ljiljana; Moser, Hans-Guenther; Mosidze, Maia; Moss, Josh; Mount, Richard; Mountricha, Eleni; Mouraviev, Sergei; Moyse, Edward; Mueller, Felix; Mueller, James; Mueller, Klemens; Müller, Thomas; Mueller, Timo; Muenstermann, Daniel; Munwes, Yonathan; Murray, Bill; Mussche, Ido; Musto, Elisa; Myagkov, Alexey; Myska, Miroslav; Nadal, Jordi; Nagai, Koichi; Nagai, Ryo; Nagano, Kunihiro; Nagarkar, Advait; Nagasaka, Yasushi; Nagel, Martin; Nairz, Armin Michael; Nakahama, Yu; Nakamura, Koji; Nakamura, Tomoaki; Nakano, Itsuo; Nanava, Gizo; Napier, Austin; Narayan, Rohin; Nash, Michael; Nattermann, Till; Naumann, Thomas; Navarro, Gabriela; Neal, Homer; Nechaeva, Polina; Neep, Thomas James; Negri, Andrea; Negri, Guido; Negrini, Matteo; Nektarijevic, Snezana; Nelson, Andrew; Nelson, Timothy Knight; Nemecek, Stanislav; Nemethy, Peter; Nepomuceno, Andre Asevedo; Nessi, Marzio; Neubauer, Mark; Neumann, Manuel; Neusiedl, Andrea; Neves, Ricardo; Nevski, Pavel; Newman, Paul; Nguyen Thi Hong, Van; Nickerson, Richard; Nicolaidou, Rosy; Nicquevert, Bertrand; Niedercorn, Francois; Nielsen, Jason; Nikiforou, Nikiforos; Nikiforov, Andriy; Nikolaenko, Vladimir; Nikolic-Audit, Irena; Nikolics, Katalin; Nikolopoulos, Konstantinos; Nilsen, Henrik; Nilsson, Paul; Ninomiya, Yoichi; Nisati, Aleandro; Nisius, Richard; Nobe, Takuya; Nodulman, Lawrence; Nomachi, Masaharu; Nomidis, Ioannis; Norberg, Scarlet; Nordberg, Markus; Norton, Peter; Novakova, Jana; Nozaki, Mitsuaki; Nozka, Libor; Nugent, Ian Michael; Nuncio-Quiroz, Adriana-Elizabeth; Nunes Hanninger, Guilherme; Nunnemann, Thomas; Nurse, Emily; O'Brien, Brendan Joseph; O'Neale, Steve; O'Neil, Dugan; O'Shea, Val; Oakes, Louise Beth; Oakham, Gerald; Oberlack, Horst; Ocariz, Jose; Ochi, Atsuhiko; Oda, Susumu; Odaka, Shigeru; Odier, Jerome; Ogren, Harold; Oh, Alexander; Oh, Seog; Ohm, Christian; Ohshima, Takayoshi; Okawa, Hideki; Okumura, Yasuyuki; Okuyama, Toyonobu; Olariu, Albert; Olchevski, Alexander; Olivares Pino, Sebastian Andres; Oliveira, Miguel Alfonso; Oliveira Damazio, Denis; Oliver Garcia, Elena; Olivito, Dominick; Olszewski, Andrzej; Olszowska, Jolanta; Onofre, António; Onyisi, Peter; Oram, Christopher; Oreglia, Mark; Oren, Yona; Orestano, Domizia; Orlando, Nicola; Orlov, Iliya; Oropeza Barrera, Cristina; Orr, Robert; Osculati, Bianca; Ospanov, Rustem; Osuna, Carlos; Otero y Garzon, Gustavo; Ottersbach, John; Ouchrif, Mohamed; Ouellette, Eric; Ould-Saada, Farid; Ouraou, Ahmimed; Ouyang, Qun; Ovcharova, Ana; Owen, Mark; Owen, Simon; Ozcan, Veysi Erkcan; Ozturk, Nurcan; Pacheco Pages, Andres; Padilla Aranda, Cristobal; Pagan Griso, Simone; Paganis, Efstathios; Pahl, Christoph; Paige, Frank; Pais, Preema; Pajchel, Katarina; Palacino, Gabriel; Paleari, Chiara; Palestini, Sandro; Pallin, Dominique; Palma, Alberto; Palmer, Jody; Pan, Yibin; Panagiotopoulou, Evgenia; Pani, Priscilla; Panikashvili, Natalia; Panitkin, Sergey; Pantea, Dan; Papadelis, Aras; Papadopoulou, Theodora; Paramonov, Alexander; Paredes Hernandez, Daniela; Park, Woochun; Parker, Andy; Parodi, Fabrizio; Parsons, John; Parzefall, Ulrich; Pashapour, Shabnaz; Pasqualucci, Enrico; Passaggio, Stefano; Passeri, Antonio; Pastore, Fernanda; Pastore, Francesca; Pásztor, Gabriella; Pataraia, Sophio; Patel, Nikhul; Pater, Joleen; Patricelli, Sergio; Pauly, Thilo; Pecsy, Martin; Pedraza Lopez, Sebastian; Pedraza Morales, Maria Isabel; Peleganchuk, Sergey; Pelikan, Daniel; Peng, Haiping; Penning, Bjoern; Penson, Alexander; Penwell, John; Perantoni, Marcelo; Perez, Kerstin; Perez Cavalcanti, Tiago; Perez Codina, Estel; Pérez García-Estañ, María Teresa; Perez Reale, Valeria; Perini, Laura; Pernegger, Heinz; Perrino, Roberto; Perrodo, Pascal; Peshekhonov, Vladimir; Peters, Krisztian; Petersen, Brian; Petersen, Jorgen; Petersen, Troels; Petit, Elisabeth; Petridis, Andreas; Petridou, Chariclia; Petrolo, Emilio; Petrucci, Fabrizio; Petschull, Dennis; Petteni, Michele; Pezoa, Raquel; Phan, Anna; Phillips, Peter William; Piacquadio, Giacinto; Picazio, Attilio; Piccaro, Elisa; Piccinini, Maurizio; Piec, Sebastian Marcin; Piegaia, Ricardo; Pignotti, David; Pilcher, James; Pilkington, Andrew; Pina, João Antonio; Pinamonti, Michele; Pinder, Alex; Pinfold, James; Pinto, Belmiro; Pizio, Caterina; Plamondon, Mathieu; Pleier, Marc-Andre; Plotnikova, Elena; Poblaguev, Andrei; Poddar, Sahill; Podlyski, Fabrice; Poggioli, Luc; Pohl, David-leon; Pohl, Martin; Polesello, Giacomo; Policicchio, Antonio; Polini, Alessandro; Poll, James; Polychronakos, Venetios; Pomeroy, Daniel; Pommès, Kathy; Pontecorvo, Ludovico; Pope, Bernard; Popeneciu, Gabriel Alexandru; Popovic, Dragan; Poppleton, Alan; Portell Bueso, Xavier; Pospelov, Guennady; Pospisil, Stanislav; Potrap, Igor; Potter, Christina; Potter, Christopher; Poulard, Gilbert; Poveda, Joaquin; Pozdnyakov, Valery; Prabhu, Robindra; Pralavorio, Pascal; Pranko, Aliaksandr; Prasad, Srivas; Pravahan, Rishiraj; Prell, Soeren; Pretzl, Klaus Peter; Price, Darren; Price, Joe; Price, Lawrence; Prieur, Damien; Primavera, Margherita; Prokofiev, Kirill; Prokoshin, Fedor; Protopopescu, Serban; Proudfoot, James; Prudent, Xavier; Przybycien, Mariusz; Przysiezniak, Helenka; Psoroulas, Serena; Ptacek, Elizabeth; Pueschel, Elisa; Purdham, John; Purohit, Milind; Puzo, Patrick; Pylypchenko, Yuriy; Qian, Jianming; Quadt, Arnulf; Quarrie, David; Quayle, William; Quinonez, Fernando; Raas, Marcel; Radescu, Voica; Radloff, Peter; Rador, Tonguc; Ragusa, Francesco; Rahal, Ghita; Rahimi, Amir; Rahm, David; Rajagopalan, Srinivasan; Rammensee, Michael; Rammes, Marcus; Randle-Conde, Aidan Sean; Randrianarivony, Koloina; Rauscher, Felix; Rave, Tobias Christian; Raymond, Michel; Read, Alexander Lincoln; Rebuzzi, Daniela; Redelbach, Andreas; Redlinger, George; Reece, Ryan; Reeves, Kendall; Reinherz-Aronis, Erez; Reinsch, Andreas; Reisinger, Ingo; Rembser, Christoph; Ren, Zhongliang; Renaud, Adrien; Rescigno, Marco; Resconi, Silvia; Resende, Bernardo; Reznicek, Pavel; Rezvani, Reyhaneh; Richter, Robert; Richter-Was, Elzbieta; Ridel, Melissa; Rijpstra, Manouk; Rijssenbeek, Michael; Rimoldi, Adele; Rinaldi, Lorenzo; Rios, Ryan Randy; Riu, Imma; Rivoltella, Giancesare; Rizatdinova, Flera; Rizvi, Eram; Robertson, Steven; Robichaud-Veronneau, Andree; Robinson, Dave; Robinson, James; Robson, Aidan; Rocha de Lima, Jose Guilherme; Roda, Chiara; Roda Dos Santos, Denis; Roe, Adam; Roe, Shaun; Røhne, Ole; Rolli, Simona; Romaniouk, Anatoli; Romano, Marino; Romeo, Gaston; Romero Adam, Elena; Rompotis, Nikolaos; Roos, Lydia; Ros, Eduardo; Rosati, Stefano; Rosbach, Kilian; Rose, Anthony; Rose, Matthew; Rosenbaum, Gabriel; Rosenberg, Eli; Rosendahl, Peter Lundgaard; Rosenthal, Oliver; Rosselet, Laurent; Rossetti, Valerio; Rossi, Elvira; Rossi, Leonardo Paolo; Rotaru, Marina; Roth, Itamar; Rothberg, Joseph; Rousseau, David; Royon, Christophe; Rozanov, Alexander; Rozen, Yoram; Ruan, Xifeng; Rubbo, Francesco; Rubinskiy, Igor; Ruckstuhl, Nicole; Rud, Viacheslav; Rudolph, Christian; Rudolph, Gerald; Rühr, Frederik; Ruiz-Martinez, Aranzazu; Rumyantsev, Leonid; Rurikova, Zuzana; Rusakovich, Nikolai; Rutherfoord, John; Ruwiedel, Christoph; Ruzicka, Pavel; Ryabov, Yury; Rybar, Martin; Rybkin, Grigori; Ryder, Nick; Saavedra, Aldo; Sadeh, Iftach; Sadrozinski, Hartmut; Sadykov, Renat; Safai Tehrani, Francesco; Sakamoto, Hiroshi; Salamanna, Giuseppe; Salamon, Andrea; Saleem, Muhammad; Salek, David; Salihagic, Denis; Salnikov, Andrei; Salt, José; Salvachua Ferrando, Belén; Salvatore, Daniela; Salvatore, Pasquale Fabrizio; Salvucci, Antonio; Salzburger, Andreas; Sampsonidis, Dimitrios; Samset, Björn Hallvard; Sanchez, Arturo; Sanchez Martinez, Victoria; Sandaker, Heidi; Sander, Heinz Georg; Sanders, Michiel; Sandhoff, Marisa; Sandoval, Tanya; Sandoval, Carlos; Sandstroem, Rikard; Sankey, Dave; Sansoni, Andrea; Santamarina Rios, Cibran; Santoni, Claudio; Santonico, Rinaldo; Santos, Helena; Saraiva, João; Sarangi, Tapas; Sarkisyan-Grinbaum, Edward; Sarri, Francesca; Sartisohn, Georg; Sasaki, Osamu; Sasaki, Yuichi; Sasao, Noboru; Satsounkevitch, Igor; Sauvage, Gilles; Sauvan, Emmanuel; Sauvan, Jean-Baptiste; Savard, Pierre; Savinov, Vladimir; Savu, Dan Octavian; Sawyer, Lee; Saxon, David; Saxon, James; Sbarra, Carla; Sbrizzi, Antonio; Scannicchio, Diana; Scarcella, Mark; Schaarschmidt, Jana; Schacht, Peter; Schaefer, Douglas; Schäfer, Uli; Schaepe, Steffen; Schaetzel, Sebastian; Schaffer, Arthur; Schaile, Dorothee; Schamberger, R. Dean; Schamov, Andrey; Scharf, Veit; Schegelsky, Valery; Scheirich, Daniel; Schernau, Michael; Scherzer, Max; Schiavi, Carlo; Schieck, Jochen; Schioppa, Marco; Schlenker, Stefan; Schmidt, Evelyn; Schmieden, Kristof; Schmitt, Christian; Schmitt, Sebastian; Schmitz, Martin; Schneider, Basil; Schnoor, Ulrike; Schoening, Andre; Schorlemmer, Andre Lukas; Schott, Matthias; Schouten, Doug; Schovancova, Jaroslava; Schram, Malachi; Schroeder, Christian; Schroer, Nicolai; Schultens, Martin Johannes; Schultes, Joachim; Schultz-Coulon, Hans-Christian; Schulz, Holger; Schumacher, Markus; Schumm, Bruce; Schune, Philippe; Schwanenberger, Christian; Schwartzman, Ariel; Schwemling, Philippe; Schwienhorst, Reinhard; Schwierz, Rainer; Schwindling, Jerome; Schwindt, Thomas; Schwoerer, Maud; Sciolla, Gabriella; Scott, Bill; Searcy, Jacob; Sedov, George; Sedykh, Evgeny; Seidel, Sally; Seiden, Abraham; Seifert, Frank; Seixas, José; Sekhniaidze, Givi; Sekula, Stephen; Selbach, Karoline Elfriede; Seliverstov, Dmitry; Sellden, Bjoern; Sellers, Graham; Seman, Michal; Semprini-Cesari, Nicola; Serfon, Cedric; Serin, Laurent; Serkin, Leonid; Seuster, Rolf; Severini, Horst; Sfyrla, Anna; Shabalina, Elizaveta; Shamim, Mansoora; Shan, Lianyou; Shank, James; Shao, Qi Tao; Shapiro, Marjorie; Shatalov, Pavel; Shaw, Kate; Sherman, Daniel; Sherwood, Peter; Shibata, Akira; Shimizu, Shima; Shimojima, Makoto; Shin, Taeksu; Shiyakova, Maria; Shmeleva, Alevtina; Shochet, Mel; Short, Daniel; Shrestha, Suyog; Shulga, Evgeny; Shupe, Michael; Sicho, Petr; Sidoti, Antonio; Siegert, Frank; Sijacki, Djordje; Silbert, Ohad; Silva, José; Silver, Yiftah; Silverstein, Daniel; Silverstein, Samuel; Simak, Vladislav; Simard, Olivier; Simic, Ljiljana; Simion, Stefan; Simioni, Eduard; Simmons, Brinick; Simoniello, Rosa; Simonyan, Margar; Sinervo, Pekka; Sinev, Nikolai; Sipica, Valentin; Siragusa, Giovanni; Sircar, Anirvan; Sisakyan, Alexei; Sivoklokov, Serguei; Sjölin, Jörgen; Sjursen, Therese; Skinnari, Louise Anastasia; Skottowe, Hugh Philip; Skovpen, Kirill; Skubic, Patrick; Slater, Mark; Slavicek, Tomas; Sliwa, Krzysztof; Smakhtin, Vladimir; Smart, Ben; Smirnov, Sergei; Smirnov, Yury; Smirnova, Lidia; Smirnova, Oxana; Smith, Ben Campbell; Smith, Douglas; Smith, Kenway; Smizanska, Maria; Smolek, Karel; Snesarev, Andrei; Snow, Steve; Snow, Joel; Snyder, Scott; Sobie, Randall; Sodomka, Jaromir; Soffer, Abner; Solans, Carlos; Solar, Michael; Solc, Jaroslav; Soldatov, Evgeny; Soldevila, Urmila; Solfaroli Camillocci, Elena; Solodkov, Alexander; Solovyanov, Oleg; Solovyev, Victor; Soni, Nitesh; Sopko, Vit; Sopko, Bruno; Sosebee, Mark; Soualah, Rachik; Soukharev, Andrey; Spagnolo, Stefania; Spanò, Francesco; Spighi, Roberto; Spigo, Giancarlo; Spiwoks, Ralf; Spousta, Martin; Spreitzer, Teresa; Spurlock, Barry; St Denis, Richard Dante; Stahlman, Jonathan; Stamen, Rainer; Stanecka, Ewa; Stanek, Robert; Stanescu, Cristian; Stanescu-Bellu, Madalina; Stapnes, Steinar; Starchenko, Evgeny; Stark, Jan; Staroba, Pavel; Starovoitov, Pavel; Staszewski, Rafal; Staude, Arnold; Stavina, Pavel; Steele, Genevieve; Steinbach, Peter; Steinberg, Peter; Stekl, Ivan; Stelzer, Bernd; Stelzer, Harald Joerg; Stelzer-Chilton, Oliver; Stenzel, Hasko; Stern, Sebastian; Stewart, Graeme; Stillings, Jan Andre; Stockton, Mark; Stoerig, Kathrin; Stoicea, Gabriel; Stonjek, Stefan; Strachota, Pavel; Stradling, Alden; Straessner, Arno; Strandberg, Jonas; Strandberg, Sara; Strandlie, Are; Strang, Michael; Strauss, Emanuel; Strauss, Michael; Strizenec, Pavol; Ströhmer, Raimund; Strom, David; Strong, John; Stroynowski, Ryszard; Strube, Jan; Stugu, Bjarne; Stumer, Iuliu; Stupak, John; Sturm, Philipp; Styles, Nicholas Adam; Soh, Dart-yin; Su, Dong; Subramania, Halasya Siva; Succurro, Antonella; Sugaya, Yorihito; Suhr, Chad; Suk, Michal; Sulin, Vladimir; Sultansoy, Saleh; Sumida, Toshi; Sun, Xiaohu; Sundermann, Jan Erik; Suruliz, Kerim; Susinno, Giancarlo; Sutton, Mark; Suzuki, Yu; Suzuki, Yuta; Svatos, Michal; Swedish, Stephen; Sykora, Ivan; Sykora, Tomas; Sánchez, Javier; Ta, Duc; Tackmann, Kerstin; Taffard, Anyes; Tafirout, Reda; Taiblum, Nimrod; Takahashi, Yuta; Takai, Helio; Takashima, Ryuichi; Takeda, Hiroshi; Takeshita, Tohru; Takubo, Yosuke; Talby, Mossadek; Talyshev, Alexey; Tamsett, Matthew; Tanaka, Junichi; Tanaka, Reisaburo; Tanaka, Satoshi; Tanaka, Shuji; Tanasijczuk, Andres Jorge; Tani, Kazutoshi; Tannoury, Nancy; Tapprogge, Stefan; Tardif, Dominique; Tarem, Shlomit; Tarrade, Fabien; Tartarelli, Giuseppe Francesco; Tas, Petr; Tasevsky, Marek; Tassi, Enrico; Tatarkhanov, Mous; Tayalati, Yahya; Taylor, Christopher; Taylor, Frank; Taylor, Geoffrey; Taylor, Wendy; Teinturier, Marthe; Teischinger, Florian Alfred; Teixeira Dias Castanheira, Matilde; Teixeira-Dias, Pedro; Temming, Kim Katrin; Ten Kate, Herman; Teng, Ping-Kun; Terada, Susumu; Terashi, Koji; Terron, Juan; Testa, Marianna; Teuscher, Richard; Therhaag, Jan; Theveneaux-Pelzer, Timothée; Thoma, Sascha; Thomas, Juergen; Thompson, Emily; Thompson, Paul; Thompson, Peter; Thompson, Stan; Thomsen, Lotte Ansgaard; Thomson, Evelyn; Thomson, Mark; Thong, Wai Meng; Thun, Rudolf; Tian, Feng; Tibbetts, Mark James; Tic, Tomáš; Tikhomirov, Vladimir; Tikhonov, Yury; Timoshenko, Sergey; Tipton, Paul; Tisserant, Sylvain; Todorov, Theodore; Todorova-Nova, Sharka; Toggerson, Brokk; Tojo, Junji; Tokár, Stanislav; Tokushuku, Katsuo; Tollefson, Kirsten; Tomoto, Makoto; Tompkins, Lauren; Toms, Konstantin; Tonoyan, Arshak; Topfel, Cyril; Topilin, Nikolai; Torchiani, Ingo; Torrence, Eric; Torres, Heberth; Torró Pastor, Emma; Toth, Jozsef; Touchard, Francois; Tovey, Daniel; Trefzger, Thomas; Tremblet, Louis; Tricoli, Alesandro; Trigger, Isabel Marian; Trincaz-Duvoid, Sophie; Tripiana, Martin; Triplett, Nathan; Trischuk, William; Trocmé, Benjamin; Troncon, Clara; Trottier-McDonald, Michel; Trzebinski, Maciej; Trzupek, Adam; Tsarouchas, Charilaos; Tseng, Jeffrey; Tsiakiris, Menelaos; Tsiareshka, Pavel; Tsionou, Dimitra; Tsipolitis, Georgios; Tsiskaridze, Shota; Tsiskaridze, Vakhtang; Tskhadadze, Edisher; Tsukerman, Ilya; Tsulaia, Vakhtang; Tsung, Jieh-Wen; Tsuno, Soshi; Tsybychev, Dmitri; Tua, Alan; Tudorache, Alexandra; Tudorache, Valentina; Tuggle, Joseph; Turala, Michal; Turecek, Daniel; Turk Cakir, Ilkay; Turlay, Emmanuel; Turra, Ruggero; Tuts, Michael; Tykhonov, Andrii; Tylmad, Maja; Tyndel, Mike; Tzanakos, George; Uchida, Kirika; Ueda, Ikuo; Ueno, Ryuichi; Ugland, Maren; Uhlenbrock, Mathias; Uhrmacher, Michael; Ukegawa, Fumihiko; Unal, Guillaume; Undrus, Alexander; Unel, Gokhan; Unno, Yoshinobu; Urbaniec, Dustin; Usai, Giulio; Uslenghi, Massimiliano; Vacavant, Laurent; Vacek, Vaclav; Vachon, Brigitte; Vahsen, Sven; Valenta, Jan; Valentinetti, Sara; Valero, Alberto; Valkar, Stefan; Valladolid Gallego, Eva; Vallecorsa, Sofia; Valls Ferrer, Juan Antonio; Van Der Deijl, Pieter; van der Geer, Rogier; van der Graaf, Harry; Van Der Leeuw, Robin; van der Poel, Egge; van der Ster, Daniel; van Eldik, Niels; van Gemmeren, Peter; van Vulpen, Ivo; Vanadia, Marco; Vandelli, Wainer; Vaniachine, Alexandre; Vankov, Peter; Vannucci, Francois; Vari, Riccardo; Varol, Tulin; Varouchas, Dimitris; Vartapetian, Armen; Varvell, Kevin; Vassilakopoulos, Vassilios; Vazeille, Francois; Vazquez Schroeder, Tamara; Vegni, Guido; Veillet, Jean-Jacques; Veloso, Filipe; Veness, Raymond; Veneziano, Stefano; Ventura, Andrea; Ventura, Daniel; Venturi, Manuela; Venturi, Nicola; Vercesi, Valerio; Verducci, Monica; Verkerke, Wouter; Vermeulen, Jos; Vest, Anja; Vetterli, Michel; Vichou, Irene; Vickey, Trevor; Vickey Boeriu, Oana Elena; Viehhauser, Georg; Viel, Simon; Villa, Mauro; Villaplana Perez, Miguel; Vilucchi, Elisabetta; Vincter, Manuella; Vinek, Elisabeth; Vinogradov, Vladimir; Virchaux, Marc; Virzi, Joseph; Vitells, Ofer; Viti, Michele; Vivarelli, Iacopo; Vives Vaque, Francesc; Vlachos, Sotirios; Vladoiu, Dan; Vlasak, Michal; Vogel, Adrian; Vokac, Petr; Volpi, Guido; Volpi, Matteo; Volpini, Giovanni; von der Schmitt, Hans; von Radziewski, Holger; von Toerne, Eckhard; Vorobel, Vit; Vorwerk, Volker; Vos, Marcel; Voss, Rudiger; Voss, Thorsten Tobias; Vossebeld, Joost; Vranjes, Nenad; Vranjes Milosavljevic, Marija; Vrba, Vaclav; Vreeswijk, Marcel; Vu Anh, Tuan; Vuillermet, Raphael; Vukotic, Ilija; Wagner, Wolfgang; Wagner, Peter; Wahlen, Helmut; Wahrmund, Sebastian; Wakabayashi, Jun; Walch, Shannon; Walder, James; Walker, Rodney; Walkowiak, Wolfgang; Wall, Richard; Waller, Peter; Walsh, Brian; Wang, Chiho; Wang, Haichen; Wang, Hulin; Wang, Jike; Wang, Jin; Wang, Rui; Wang, Song-Ming; Wang, Tan; Warburton, Andreas; Ward, Patricia; Warsinsky, Markus; Washbrook, Andrew; Wasicki, Christoph; Watanabe, Ippei; Watkins, Peter; Watson, Alan; Watson, Ian; Watson, Miriam; Watts, Gordon; Watts, Stephen; Waugh, Anthony; Waugh, Ben; Weber, Michele; Weber, Pavel; Weidberg, Anthony; Weigell, Philipp; Weingarten, Jens; Weiser, Christian; Wellenstein, Hermann; Wells, Phillippa; Wenaus, Torre; Wendland, Dennis; Weng, Zhili; Wengler, Thorsten; Wenig, Siegfried; Wermes, Norbert; Werner, Matthias; Werner, Per; Werth, Michael; Wessels, Martin; Wetter, Jeffrey; Weydert, Carole; Whalen, Kathleen; Wheeler-Ellis, Sarah Jane; White, Andrew; White, Martin; White, Sebastian; Whitehead, Samuel Robert; Whiteson, Daniel; Whittington, Denver; Wicek, Francois; Wicke, Daniel; Wickens, Fred; Wiedenmann, Werner; Wielers, Monika; Wienemann, Peter; Wiglesworth, Craig; Wiik-Fuchs, Liv Antje Mari; Wijeratne, Peter Alexander; Wildauer, Andreas; Wildt, Martin Andre; Wilhelm, Ivan; Wilkens, Henric George; Will, Jonas Zacharias; Williams, Eric; Williams, Hugh; Willis, William; Willocq, Stephane; Wilson, John; Wilson, Michael Galante; Wilson, Alan; Wingerter-Seez, Isabelle; Winkelmann, Stefan; Winklmeier, Frank; Wittgen, Matthias; Wollstadt, Simon Jakob; Wolter, Marcin Wladyslaw; Wolters, Helmut; Wong, Wei-Cheng; Wooden, Gemma; Wosiek, Barbara; Wotschack, Jorg; Woudstra, Martin; Wozniak, Krzysztof; Wraight, Kenneth; Wright, Michael; Wrona, Bozydar; Wu, Sau Lan; Wu, Xin; Wu, Yusheng; Wulf, Evan; Wynne, Benjamin; Xella, Stefania; Xiao, Meng; Xie, Song; Xu, Chao; Xu, Da; Yabsley, Bruce; Yacoob, Sahal; Yamada, Miho; Yamaguchi, Hiroshi; Yamamoto, Akira; Yamamoto, Kyoko; Yamamoto, Shimpei; Yamamura, Taiki; Yamanaka, Takashi; Yamaoka, Jared; Yamazaki, Takayuki; Yamazaki, Yuji; Yan, Zhen; Yang, Haijun; Yang, Un-Ki; Yang, Yi; Yang, Zhaoyu; Yanush, Serguei; Yao, Liwen; Yao, Yushu; Yasu, Yoshiji; Ybeles Smit, Gabriel Valentijn; Ye, Jingbo; Ye, Shuwei; Yilmaz, Metin; Yoosoofmiya, Reza; Yorita, Kohei; Yoshida, Riktura; Young, Charles; Young, Christopher John; Youssef, Saul; Yu, Dantong; Yu, Jaehoon; Yu, Jie; Yuan, Li; Yurkewicz, Adam; Byszewski, Marcin; Zabinski, Bartlomiej; Zaidan, Remi; Zaitsev, Alexander; Zajacova, Zuzana; Zanello, Lucia; Zaytsev, Alexander; Zeitnitz, Christian; Zeman, Martin; Zemla, Andrzej; Zendler, Carolin; Zenin, Oleg; Ženiš, Tibor; Zinonos, Zinonas; Zenz, Seth; Zerwas, Dirk; Zevi della Porta, Giovanni; Zhan, Zhichao; Zhang, Dongliang; Zhang, Huaqiao; Zhang, Jinlong; Zhang, Xueyao; Zhang, Zhiqing; Zhao, Long; Zhao, Tianchi; Zhao, Zhengguo; Zhemchugov, Alexey; Zhong, Jiahang; Zhou, Bing; Zhou, Ning; Zhou, Yue; Zhu, Cheng Guang; Zhu, Hongbo; Zhu, Junjie; Zhu, Yingchun; Zhuang, Xuai; Zhuravlov, Vadym; Zieminska, Daria; Zimin, Nikolai; Zimmermann, Robert; Zimmermann, Simone; Zimmermann, Stephanie; Ziolkowski, Michael; Zitoun, Robert; Živković, Lidija; Zmouchko, Viatcheslav; Zobernig, Georg; Zoccoli, Antonio; zur Nedden, Martin; Zutshi, Vishnu; Zwalinski, Lukasz

    2013-08-06

    The measurement of several event shape variables is presented in minimum bias pp collisions at a center-of-mass energy of 7 TeV using the ATLAS detector at the LHC. The observables studied are the transverse thrust, thrust minor and transverse sphericity, each defined using the momenta perpendicular to the beam direction of the final state charged particles. Events with at least six charged particles are selected. In addition to the differential distributions, the evolution of each event shape variable as a function of the leading charged particle transverse momentum, charged particle multiplicity and summed transverse momentum is presented. Predictions from several Monte Carlo models have been compared with data and they show significant deviations from data.

  14. Test--retest variability of Randot stereoacuity measures gathered in an unselected sample of UK primary school children.

    Science.gov (United States)

    Adler, Paul; Scally, Andrew J; Barrett, Brendan T

    2012-05-01

    To determine the test-retest reliability of the Randot stereoacuity test when used as part of vision screening in schools. Randot stereoacuity (graded-circles) and logMAR visual acuity measures were gathered in an unselected sample of 139 children (aged 4-12, mean 8.1±2.1 years) in two schools. Randot testing was repeated on two occasions (average interval between successive tests 8 days, range: 1-21 days). Three Randot scores were obtained in 97.8% of children. Randot stereoacuity improved by an average of one plate (ie, one test level) on repeat testing but was little changed when tested on the third occasion. Within-subject variability was up to three test levels on repeat testing. When stereoacuity was categorised as 'fine', 'intermediate' or 'coarse', the greatest variability was found among younger children who exhibited 'intermediate' or 'coarse'/nil stereopsis on initial testing. Whereas 90.8% of children with 'fine' stereopsis (≤50 arc-seconds) on the first test exhibited 'fine' stereopsis on both subsequent tests, only ∼16% of children with 'intermediate' (>50 but ≤140 arc-seconds) or 'coarse'/nil (≥200 arc-seconds) stereoacuity on initial testing exhibited stable test results on repeat testing. Children exhibiting abnormal stereoacuity on initial testing are very likely to exhibit a normal result when retested. The value of a single, abnormal Randot graded-circles stereoacuity measure from school screening is therefore questionable.

  15. Genetic Influence on Slope Variability in a Childhood Reflexive Attention Task.

    Directory of Open Access Journals (Sweden)

    Rebecca A Lundwall

    Full Text Available Individuals are not perfectly consistent, and interindividual variability is a common feature in all varieties of human behavior. Some individuals respond more variably than others, however, and this difference may be important to understanding how the brain works. In this paper, we explore genetic contributions to response time (RT slope variability on a reflexive attention task. We are interested in such variability because we believe it is an important part of the overall picture of attention that, if understood, has the potential to improve intervention for those with attentional deficits. Genetic association studies are valuable in discovering biological pathways of variability and several studies have found such associations with a sustained attention task. Here, we expand our knowledge to include a reflexive attention task. We ask whether specific candidate genes are associated with interindividual variability on a childhood reflexive attention task in 9-16 year olds. The genetic makers considered are on 11 genes: APOE, BDNF, CHRNA4, COMT, DRD4, HTR4, IGF2, MAOA, SLC5A7, SLC6A3, and SNAP25. We find significant associations with variability with markers on nine and we discuss the results in terms of neurotransmitters associated with each gene and the characteristics of the associated measures from the reflexive attention task.

  16. Prefrontal Hemodynamics in Toddlers at Rest: A Pilot Study of Developmental Variability

    Directory of Open Access Journals (Sweden)

    Afrouz A. Anderson

    2017-05-01

    Full Text Available Functional near infrared spectroscopy (fNIRS is a non-invasive functional neuroimaging modality. Although, it is amenable to use in infants and young children, there is a lack of fNIRS research within the toddler age range. In this study, we used fNIRS to measure cerebral hemodynamics in the prefrontal cortex (PFC in 18–36 months old toddlers (n = 29 as part of a longitudinal study that enrolled typically-developing toddlers as well as those “at risk” for language and other delays based on presence of early language delays. In these toddlers, we explored two hemodynamic response indices during periods of rest during which time audiovisual children's programming was presented. First, we investigate Lateralization Index, based on differences in oxy-hemoglobin saturation from left and right prefrontal cortex. Then, we measure oxygenation variability (OV index, based on variability in oxygen saturation at frequencies attributed to cerebral autoregulation. Preliminary findings show that lower cognitive (including language abilities are associated with fNIRS measures of both lower OV index and more extreme Lateralization index values. These preliminary findings show the feasibility of using fNIRS in toddlers, including those at risk for developmental delay, and lay the groundwork for future studies.

  17. Genetic Variability in Glucosinolates in Seed of Brassica juncea: Interest in Mustard Condiment

    Directory of Open Access Journals (Sweden)

    Othmane Merah

    2015-01-01

    Full Text Available Brassica juncea is mostly used for oil production which implies selection of genotypes with low glucosinolates level and high oil content. In contrast, condiment production needs varieties with high level in some glucosinolates including sinigrin. The genetic variability was studied mostly by molecular tools. The objectives were almost the decrease of glucosinolates level in order to use the oilcake for animal feed. The aim of this work is to study the genetic variability for different glucosinolates and their relationships with agronomical traits within a large collection of Brassica juncea genotypes for condiment uses. A collection of 190 genotypes from different origins was studied in Dijon (France. Oil content and total glucosinolates, and sinigrin and gluconapin levels were measured. Flowering and maturation durations, seed yield, and yield components were also measured. Large variability was observed between genotypes for the measured traits within the studied collection. Total glucosinolates varied twofold between extreme genotypes. Values of sinigrin content varied from 0 to more than 134 µmol·g−1. Correlations between glucosinolates traits and both phenological and agronomical characters are presented and discussed for their potential for industrial condiment uses.

  18. Several real variables

    CERN Document Server

    Kantorovitz, Shmuel

    2016-01-01

    This undergraduate textbook is based on lectures given by the author on the differential and integral calculus of functions of several real variables. The book has a modern approach and includes topics such as: •The p-norms on vector space and their equivalence •The Weierstrass and Stone-Weierstrass approximation theorems •The differential as a linear functional; Jacobians, Hessians, and Taylor's theorem in several variables •The Implicit Function Theorem for a system of equations, proved via Banach’s Fixed Point Theorem •Applications to Ordinary Differential Equations •Line integrals and an introduction to surface integrals This book features numerous examples, detailed proofs, as well as exercises at the end of sections. Many of the exercises have detailed solutions, making the book suitable for self-study. Several Real Variables will be useful for undergraduate students in mathematics who have completed first courses in linear algebra and analysis of one real variable.

  19. Several complex variables

    International Nuclear Information System (INIS)

    Field, M.J.

    1976-01-01

    Topics discussed include the elementary of holomorphic functions of several complex variables; the Weierstrass preparation theorem; meromorphic functions, holomorphic line bundles and divisors; elliptic operators on compact manifolds; hermitian connections; the Hodge decomposition theorem. ( author)

  20. Variability of HOMA and QUICKI insulin sensitivity indices.

    Science.gov (United States)

    Žarković, Miloš; Ćirić, Jasmina; Beleslin, Biljana; Stojković, Mirjana; Savić, Slavica; Stojanović, Miloš; Lalić, Tijana

    2017-07-01

    Assessment of insulin sensitivity based on a single measurement of insulin and glucose, is both easy to understand and simple to perform. The tests most often used are HOMA and QUICKI. The aim of this study was to assess the biological variability of estimates of insulin sensitivity using HOMA and QUICKI indices. After a 12-h fast, blood was sampled for insulin and glucose determination. Sampling lasted for 90 min with an intersample interval of 2 min. A total of 56 subjects were included in the study, and in nine subjects sampling was done before and after weight reduction, so total number of analyzed series was 65. To compute the reference value of the insulin sensitivity index, averages of all 46 insulin and glucose samples were used. We also computed point estimates (single value estimates) of the insulin sensitivity index based on the different number of insulin/glucose samples (1-45 consecutive samples). To compute the variability of point estimates a bootstrapping procedure was used using 1000 resamples for each series and for each number of samples used to average insulin and glucose. Using a single insulin/glucose sample HOMA variability was 26.18 ± 4.31%, and QUICKI variability was 3.30 ± 0.54%. For 10 samples variability was 11.99 ± 2.22% and 1.62 ± 0.31% respectively. Biological variability of insulin sensitivity indices is significant, and it can be reduced by increasing the number of samples. Oscillations of insulin concentration in plasma are the major cause of variability of insulin sensitivity indices.

  1. Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions

    International Nuclear Information System (INIS)

    Gil, E; Orini, M; Bailón, R; Laguna, P; Vergara, J M; Mainardi, L

    2010-01-01

    In this paper we assessed the possibility of using the pulse rate variability (PRV) extracted from the photoplethysmography signal as an alternative measurement of the HRV signal in non-stationary conditions. The study is based on analysis of the changes observed during a tilt table test in the heart rate modulation of 17 young subjects. First, the classical indices of HRV analysis were compared to the indices from PRV in intervals where stationarity was assumed. Second, the time-varying spectral properties of both signals were compared by time-frequency (TF) and TF coherence analysis. Third, the effect of replacing PRV with HRV in the assessment of the changes of the autonomic modulation of the heart rate was considered. Time-invariant HRV and PRV indices showed no statistically significant differences (p > 0.05) and high correlation (>0.97). Time-frequency analysis revealed that the TF spectra of both signals were highly correlated (0.99 ± 0.01); the difference between the instantaneous power, in the LF and HF bands, obtained from HRV and PRV was small (<10 −3 s −2 ) and their temporal patterns were highly correlated (0.98 ± 0.04 and 0.95 ± 0.06 in the LF and HF bands, respectively) and TF coherence in the LF and HF bands was high (0.97 ± 0.04 and 0.89 ± 0.08, respectively). Finally, the instantaneous power in the LF band was observed to significantly increase during head-up tilt by both HRV and PRV analysis. These results suggest that although some differences in the time-varying spectral indices extracted from HRV and PRV exist, mainly in the HF band associated with respiration, PRV could be used as a surrogate of HRV during non-stationary conditions, at least during the tilt table test

  2. Linking the Observation of Essential Variables to Societal Benefits

    Science.gov (United States)

    Sylak-Glassman, E.

    2017-12-01

    Different scientific communities have established sets of commonly agreed upon essential variables to help coordinate data collection in a variety of Earth observation areas. As an example, the World Meteorological Organization Global Climate Observing System has identified 50 Essential Climate Variables (ECVs), such as sea-surface temperature and carbon dioxide, which are required to monitoring the climate and detect and attribute climate change. In addition to supporting climate science, measuring these ECVs deliver many types of societal benefits, ranging from disaster mitigation to agricultural productivity to human health. While communicating the value in maintaining and improving observational records for these variables has been a challenge, quantifying how the measurement of these ECVs results in the delivery of many different societal benefits may help support their continued measurement. The 2016 National Earth Observation Assessment (EOA 2016) quantified the impact of individual Earth observation systems, sensors, networks, and surveys (or Earth observation systems, for short) on the achievement of 217 Federal objectives in 13 societal benefit areas (SBAs). This study will demonstrate the use of the EOA 2016 dataset to show the different Federal objectives and SBAs that are impacted by the Earth observation systems used to measure ECVs. Describing how the measurements from these Earth observation systems are used not only to maintain the climate record but also to meet additional Federal objectives may help articulate the continued measurement of the ECVs. This study will act as a pilot for the use of the EOA 2016 dataset to map between the measurements required to observe additional sets of variables, such as the Essential Ocean Variables and Essential Biodiversity Variables, and the ability to achieve a variety of societal benefits.

  3. Variable stars in the classroom

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Bajo, F [Departamento de Electronica e IngenierIa Electromecanica, Escuela de IngenierIas Industriales, Universidad de Extremadura, Avda de Elvas s/n, 06071 Badajoz (Spain); Vaquero, J M [Departamento de Fisica, Escuela Politecnica, Universidad de Extremadura, Avda de la Universidad s/n, 10071 Caceres (Spain)

    2006-05-01

    Variable stars offer interesting possibilities from the point of view of educational applications, from the experimental collection of data to analysis to obtain physical information. In this paper, brightness measurements of two periodic variable stars easily accessible with small telescopes are presented and analysed. This practical experiment is highly appropriate for educational use in undergraduate physics and astrophysics laboratories and allows students to approximate scientific research.

  4. Variable stars in the classroom

    International Nuclear Information System (INIS)

    Sanchez-Bajo, F; Vaquero, J M

    2006-01-01

    Variable stars offer interesting possibilities from the point of view of educational applications, from the experimental collection of data to analysis to obtain physical information. In this paper, brightness measurements of two periodic variable stars easily accessible with small telescopes are presented and analysed. This practical experiment is highly appropriate for educational use in undergraduate physics and astrophysics laboratories and allows students to approximate scientific research

  5. Exploratory Analysis of Dengue Fever Niche Variables within the Río Magdalena Watershed

    Directory of Open Access Journals (Sweden)

    Austin Stanforth

    2016-09-01

    Full Text Available Previous research on Dengue Fever have involved laboratory tests or study areas with less diverse temperature and elevation ranges than is found in Colombia; therefore, preliminary research was needed to identify location specific attributes of Dengue Fever transmission. Environmental variables derived from the Moderate Resolution Imaging Spectroradiometer (MODIS and Tropical Rainfall Measuring Mission (TRMM satellites were combined with population variables to be statistically compared against reported cases of Dengue Fever in the Río Magdalena watershed, Colombia. Three-factor analysis models were investigated to analyze variable patterns, including a population, population density, and empirical Bayesian estimation model. Results identified varying levels of Dengue Fever transmission risk, and environmental characteristics which support, and advance, the research literature. Multiple temperature metrics, elevation, and vegetation composition were among the more contributory variables found to identify future potential outbreak locations.

  6. IRAS variables as galactic structure tracers - Classification of the bright variables

    Science.gov (United States)

    Allen, L. E.; Kleinmann, S. G.; Weinberg, M. D.

    1993-01-01

    The characteristics of the 'bright infrared variables' (BIRVs), a sample consisting of the 300 brightest stars in the IRAS Point Source Catalog with IRAS variability index VAR of 98 or greater, are investigated with the purpose of establishing which of IRAS variables are AGB stars (e.g., oxygen-rich Miras and carbon stars, as was assumed by Weinberg (1992)). Results of the analysis of optical, infrared, and microwave spectroscopy of these stars indicate that, out of 88 stars in the BIRV sample identified with cataloged variables, 86 can be classified as Miras. Results of a similar analysis performed for a color-selected sample of stars, using the color limits employed by Habing (1988) to select AGB stars, showed that, out of 52 percent of classified stars, 38 percent are non-AGB stars, including H II regions, planetary nebulae, supergiants, and young stellar objects, indicating that studies using color-selected samples are subject to misinterpretation.

  7. Analysis of the spatial variability of crop yield and soil properties in small agricultural plots

    Directory of Open Access Journals (Sweden)

    Vieira Sidney Rosa

    2003-01-01

    Full Text Available The objective of this study was to assess spatial variability of soil properties and crop yield under no tillage as a function of time, in two soil/climate conditions in São Paulo State, Brazil. The two sites measured approximately one hectare each and were cultivated with crop sequences which included corn, soybean, cotton, oats, black oats, wheat, rye, rice and green manure. Soil fertility, soil physical properties and crop yield were measured in a 10-m grid. The soils were a Dusky Red Latossol (Oxisol and a Red Yellow Latossol (Ultisol. Soil sampling was performed in each field every two years after harvesting of the summer crop. Crop yield was measured at the end of each crop cycle, in 2 x 2.5 m sub plots. Data were analysed using semivariogram analysis and kriging interpolation for contour map generation. Yield maps were constructed in order to visually compare the variability of yields, the variability of the yield components and related soil properties. The results show that the factors affecting the variability of crop yield varies from one crop to another. The changes in yield from one year to another suggest that the causes of variability may change with time. The changes with time for the cross semivariogram between phosphorus in leaves and soybean yield is another evidence of this result.

  8. Continuous-variable Measurement-device-independent Quantum Relay Network with Phase-sensitive Amplifiers

    Science.gov (United States)

    Li, Fei; Zhao, Wei; Guo, Ying

    2018-01-01

    Continuous-variable (CV) measurement-device-independent (MDI) quantum cryptography is now heading towards solving the practical problem of implementing scalable quantum networks. In this paper, we show that a solution can come from deploying an optical amplifier in the CV-MDI system, aiming to establish a high-rate quantum network. We suggest an improved CV-MDI protocol using the EPR states coupled with optical amplifiers. It can implement a practical quantum network scheme, where the legal participants create the secret correlations by using EPR states connecting to an untrusted relay via insecure links and applying the multi-entangled Greenberger-Horne-Zeilinger (GHZ) state analysis at relay station. Despite the possibility that the relay could be completely tampered with and imperfect links are subject to the powerful attacks, the legal participants are still able to extract a secret key from network communication. The numerical simulation indicates that the quantum network communication can be achieved in an asymmetric scenario, fulfilling the demands of a practical quantum network. Furthermore, we show that the use of optical amplifiers can compensate the inherent imperfections and improve the secret key rate of the CV-MDI system.

  9. Design and implementation of a versatile and variable-frequency piezoelectric coefficient measurement system.

    Science.gov (United States)

    Wu, J S; Huang, Y K; Wu, F L; Lin, D Y

    2012-08-01

    We present a simple but versatile piezoelectric coefficient measurement system, which can measure the longitudinal and transverse piezoelectric coefficients in the pressing and bending modes, respectively, at different applied forces and a wide range of frequencies. The functionality of this measurement system has been demonstrated on three samples, including a PbZr(0.52)Ti(0.48)O(3) (PZT) piezoelectric ceramic bulk, a ZnO thin film, and a laminated piezoelectric film sensor. The static longitudinal piezoelectric coefficients of the PZT bulk and the ZnO film are estimated to be around 210 and 8.1 pC/N, respectively. The static transverse piezoelectric coefficients of the ZnO film and the piezoelectric film sensor are determined to be, respectively, -0.284 and -0.031 C/m(2).

  10. Spatial and Temporal Variability in Biogenic Gas Accumulation and Release in The Greater Everglades at Multiple Scales of Measurement

    Science.gov (United States)

    McClellan, M. D.; Cornett, C.; Schaffer, L.; Comas, X.

    2017-12-01

    Wetlands play a critical role in the carbon (C) cycle by producing and releasing significant amounts of greenhouse biogenic gasses (CO2, CH4) into the atmosphere. Wetlands in tropical and subtropical climates (such as the Florida Everglades) have become of great interest in the past two decades as they account for more than 20% of the global peatland C stock and are located in climates that favor year-round C emissions. Despite the increase in research involving C emission from these types of wetlands, the spatial and temporal variability involving C production, accumulation and release is still highly uncertain, and is the focus of this research at multiple scales of measurement (i.e. lab, field and landscape). Spatial variability in biogenic gas content, build up and release, at both the lab and field scales, was estimated using a series of ground penetrating radar (GPR) surveys constrained with gas traps fitted with time-lapse cameras. Variability in gas content was estimated at the sub-meter scale (lab scale) within two extracted monoliths from different wetland ecosystems at the Disney wilderness Preserve (DWP) and the Blue Cypress Preserve (BCP) using high frequency GPR (1.2 GHz) transects across the monoliths. At the field scale (> 10m) changes in biogenic gas content were estimated using 160 MHz GPR surveys collected within 4 different emergent wetlands at the DWP. Additionally, biogenic gas content from the extracted monoliths was used to developed a landscape comparison of C accumulation and emissions for each different wetland ecosystem. Changes in gas content over time were estimated at the lab scale at high temporal resolution (i.e. sub-hourly) in monoliths from the BCP and Water Conservation Area 1-A. An autonomous rail system was constructed to estimate biogenic gas content variability within the wetland soil matrix using a series of continuous, uninterrupted 1.2 GHz GPR transects along the samples. Measurements were again constrained with an array

  11. Importance analysis for models with correlated variables and its sparse grid solution

    International Nuclear Information System (INIS)

    Li, Luyi; Lu, Zhenzhou

    2013-01-01

    For structural models involving correlated input variables, a novel interpretation for variance-based importance measures is proposed based on the contribution of the correlated input variables to the variance of the model output. After the novel interpretation of the variance-based importance measures is compared with the existing ones, two solutions of the variance-based importance measures of the correlated input variables are built on the sparse grid numerical integration (SGI): double-loop nested sparse grid integration (DSGI) method and single loop sparse grid integration (SSGI) method. The DSGI method solves the importance measure by decreasing the dimensionality of the input variables procedurally, while SSGI method performs importance analysis through extending the dimensionality of the inputs. Both of them can make full use of the advantages of the SGI, and are well tailored for different situations. By analyzing the results of several numerical and engineering examples, it is found that the novel proposed interpretation about the importance measures of the correlated input variables is reasonable, and the proposed methods for solving importance measures are efficient and accurate. -- Highlights: •The contribution of correlated variables to the variance of the output is analyzed. •A novel interpretation for variance-based indices of correlated variables is proposed. •Two solutions for variance-based importance measures of correlated variables are built

  12. Ratio index variables or ANCOVA? Fisher's cats revisited.

    Science.gov (United States)

    Tu, Yu-Kang; Law, Graham R; Ellison, George T H; Gilthorpe, Mark S

    2010-01-01

    Over 60 years ago Ronald Fisher demonstrated a number of potential pitfalls with statistical analyses using ratio variables. Nonetheless, these pitfalls are largely overlooked in contemporary clinical and epidemiological research, which routinely uses ratio variables in statistical analyses. This article aims to demonstrate how very different findings can be generated as a result of less than perfect correlations among the data used to generate ratio variables. These imperfect correlations result from measurement error and random biological variation. While the former can often be reduced by improvements in measurement, random biological variation is difficult to estimate and eliminate in observational studies. Moreover, wherever the underlying biological relationships among epidemiological variables are unclear, and hence the choice of statistical model is also unclear, the different findings generated by different analytical strategies can lead to contradictory conclusions. Caution is therefore required when interpreting analyses of ratio variables whenever the underlying biological relationships among the variables involved are unspecified or unclear. (c) 2009 John Wiley & Sons, Ltd.

  13. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    International Nuclear Information System (INIS)

    Moselewski, Fabian; Ferencik, Maros; Achenbach, Stephan; Abbara, Suhny; Cury, Ricardo C.; Booth, Sarah L.; Jang, Ik-Kyung; Brady, Thomas J.; Hoffmann, Udo

    2006-01-01

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 ± 68.7 HU versus 295 ± 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT

  14. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moselewski, Fabian [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Ferencik, Maros [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Achenbach, Stephan [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Internal Medicine II (Cardiology), University of Erlangen (Germany); Abbara, Suhny [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Booth, Sarah L. [Jean Mayer USDA Human Nutrition Research Center on Aging, 711 Washington St., Boston, MA 02114 (United States); Jang, Ik-Kyung [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Brady, Thomas J. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)]. E-mail: uhoffman@partners.org

    2006-03-15

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM] at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 {+-} 68.7 HU versus 295 {+-} 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.

  15. Investigating Reliabilities of Intraindividual Variability Indicators

    Science.gov (United States)

    Wang, Lijuan; Grimm, Kevin J.

    2012-01-01

    Reliabilities of the two most widely used intraindividual variability indicators, "ISD[superscript 2]" and "ISD", are derived analytically. Both are functions of the sizes of the first and second moments of true intraindividual variability, the size of the measurement error variance, and the number of assessments within a burst. For comparison,…

  16. Assessment and quantification of sources of variability in breast apparent diffusion coefficient (ADC) measurements at diffusion weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giannotti, E., E-mail: ytteb84@hotmail.com [Breast Imaging Department, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Waugh, S., E-mail: shelley.waugh@nhs.net [Department of Medical Physics, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Department of Clinical Radiology, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Priba, L., E-mail: lpriba@nhs.net [Department of Medical Physics, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Davis, Z., E-mail: zoedavis@doctors.org.uk [Breast Imaging Department, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Crowe, E., E-mail: e.crowe@nhs.net [Department of Clinical Radiology, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Vinnicombe, S., E-mail: s.vinnicombe@dundee.ac.uk [Division of Imaging and Technology, Ninewells Hospital and Medical School, University of Dundee, Dundee DD1 9SY (United Kingdom)

    2015-09-15

    Highlights: • Inter-scan errors have minimal contribution to ADC measurement variability. • Intra-observer measures of ADC values in breast cancer are excellent. • ADC measures in whole tumour are more reproducible than minimum ADC measures. • ADC measurement error is most influenced by multiple readers. - Abstract: Purpose: Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may be encountered in such follow-up studies- namely scanner stability, scan–scan reproducibility, inter- and intra- observer measures and the most reproducible measurement of ADC. Methods: Institutional Review Board approval was obtained for the prospective study of healthy volunteers and written consent acquired for the retrospective study of patient images. All scanning was performed on a 3.0-T MRI scanner. Scanner stability was assessed using an ice-water phantom weekly for 12 weeks. Inter-scan repeatability was assessed across two scans of 10 healthy volunteers (26–61 years; mean: 44.7 years). Inter- and intra-reader analysis repeatability was measured in 52 carcinomas from clinical patients (29–70 years; mean: 50.0 years) by measuring the whole tumor ADC value on a single slice with maximum tumor diameter (ADC{sub S}) and the ADC value of a small region of interest (ROI) on the same slice (ADC{sub min}). Repeatability was assessed using intraclass correlation coefficients (ICC) and coefficients of repeatability (CoR). Results: Scanner stability contributed 6% error to phantom ADC measurements (0.071 × 10{sup −3} mm{sup 2}/s; mean ADC = 1.089 × 10{sup −3} mm{sup 2}/s). The measured scan-scan CoR in the volunteers was 0.122 × 10{sup −3} mm{sup 2}/s, contributing an error of 8% to the mean measured values (ADC

  17. Ancilla-driven quantum computation for qudits and continuous variables

    Science.gov (United States)

    Proctor, Timothy; Giulian, Melissa; Korolkova, Natalia; Andersson, Erika; Kendon, Viv

    2017-05-01

    Although qubits are the leading candidate for the basic elements in a quantum computer, there are also a range of reasons to consider using higher-dimensional qudits or quantum continuous variables (QCVs). In this paper, we use a general "quantum variable" formalism to propose a method of quantum computation in which ancillas are used to mediate gates on a well-isolated "quantum memory" register and which may be applied to the setting of qubits, qudits (for d >2 ), or QCVs. More specifically, we present a model in which universal quantum computation may be implemented on a register using only repeated applications of a single fixed two-body ancilla-register interaction gate, ancillas prepared in a single state, and local measurements of these ancillas. In order to maintain determinism in the computation, adaptive measurements via a classical feed forward of measurement outcomes are used, with the method similar to that in measurement-based quantum computation (MBQC). We show that our model has the same hybrid quantum-classical processing advantages as MBQC, including the power to implement any Clifford circuit in essentially one layer of quantum computation. In some physical settings, high-quality measurements of the ancillas may be highly challenging or not possible, and hence we also present a globally unitary model which replaces the need for measurements of the ancillas with the requirement for ancillas to be prepared in states from a fixed orthonormal basis. Finally, we discuss settings in which these models may be of practical interest.

  18. Using structural equation modeling to investigate relationships among ecological variables

    Science.gov (United States)

    Malaeb, Z.A.; Kevin, Summers J.; Pugesek, B.H.

    2000-01-01

    Structural equation modeling is an advanced multivariate statistical process with which a researcher can construct theoretical concepts, test their measurement reliability, hypothesize and test a theory about their relationships, take into account measurement errors, and consider both direct and indirect effects of variables on one another. Latent variables are theoretical concepts that unite phenomena under a single term, e.g., ecosystem health, environmental condition, and pollution (Bollen, 1989). Latent variables are not measured directly but can be expressed in terms of one or more directly measurable variables called indicators. For some researchers, defining, constructing, and examining the validity of latent variables may be the end task of itself. For others, testing hypothesized relationships of latent variables may be of interest. We analyzed the correlation matrix of eleven environmental variables from the U.S. Environmental Protection Agency's (USEPA) Environmental Monitoring and Assessment Program for Estuaries (EMAP-E) using methods of structural equation modeling. We hypothesized and tested a conceptual model to characterize the interdependencies between four latent variables-sediment contamination, natural variability, biodiversity, and growth potential. In particular, we were interested in measuring the direct, indirect, and total effects of sediment contamination and natural variability on biodiversity and growth potential. The model fit the data well and accounted for 81% of the variability in biodiversity and 69% of the variability in growth potential. It revealed a positive total effect of natural variability on growth potential that otherwise would have been judged negative had we not considered indirect effects. That is, natural variability had a negative direct effect on growth potential of magnitude -0.3251 and a positive indirect effect mediated through biodiversity of magnitude 0.4509, yielding a net positive total effect of 0

  19. Reduction in camera-specific variability in [(123)I]FP-CIT SPECT outcome measures by image reconstruction optimized for multisite settings

    DEFF Research Database (Denmark)

    Buchert, Ralph; Kluge, Andreas; Tossici-Bolt, Livia

    2016-01-01

    the Southampton method with binding in the whole brain, occipital cortex or cerebellum as the reference. The correlation between SBR and age was used as the primary quality measure. RESULTS: The fraction of SBR variability explained by age was highest (1) with QSPECT, independently of the reference region, and (2...... as the reference provides more stable quantitative estimates than occipital or cerebellar binding....

  20. Capturing the dynamics of response variability in the brain in ADHD

    Directory of Open Access Journals (Sweden)

    Janna van Belle

    2015-01-01

    Full Text Available ADHD is characterized by increased intra-individual variability in response times during the performance of cognitive tasks. However, little is known about developmental changes in intra-individual variability, and how these changes relate to cognitive performance. Twenty subjects with ADHD aged 7–24 years and 20 age-matched, typically developing controls participated in an fMRI-scan while they performed a go-no-go task. We fit an ex-Gaussian distribution on the response distribution to objectively separate extremely slow responses, related to lapses of attention, from variability on fast responses. We assessed developmental changes in these intra-individual variability measures, and investigated their relation to no-go performance. Results show that the ex-Gaussian measures were better predictors of no-go performance than traditional measures of reaction time. Furthermore, we found between-group differences in the change in ex-Gaussian parameters with age, and their relation to task performance: subjects with ADHD showed age-related decreases in their variability on fast responses (sigma, but not in lapses of attention (tau, whereas control subjects showed a decrease in both measures of variability. For control subjects, but not subjects with ADHD, this age-related reduction in variability was predictive of task performance. This group difference was reflected in neural activation: for typically developing subjects, the age-related decrease in intra-individual variability on fast responses (sigma predicted activity in the dorsal anterior cingulate gyrus (dACG, whereas for subjects with ADHD, activity in this region was related to improved no-go performance with age, but not to intra-individual variability. These data show that using more sophisticated measures of intra-individual variability allows the capturing of the dynamics of task performance and associated neural changes not permitted by more traditional measures.

  1. Relation between task complexity and variability of procedure progression during an emergency operation

    International Nuclear Information System (INIS)

    Kim, Yochan; Park, Jinkyun; Jung, Wondea

    2013-01-01

    Highlights: • The relation between task complexity and the variability of procedure progression was investigated. • The two quantitative measures, TACOM and VPP, were applied to this study. • The task complexity was positively related with the operator’s procedural variability. • The VPP measure can be useful for explaining the operator’s behaviors. - Abstract: In this study, the relation between task complexity and variability of procedure progression during an emergency operation was investigated by comparing the two quantitative measures. To this end, the TACOM measure and VPP measure were applied to evaluate the complexity of tasks and variability of procedure progression, respectively. The TACOM scores and VPP scores were obtained for 60 tasks in the OPERA database, and a correlation analysis between two measures and a multiple regression analysis between the sub-measures of the TACOM measure and VPP measure were conducted. The results showed that the TACOM measure is positively associated with the VPP measure, and the abstraction hierarchy complexity mainly affected the variability among the sub-measures of TACOM. From these findings, it was discussed that the task complexity is related to an operator’s procedural variability and VPP measure can be useful for explaining the operator’s behaviors

  2. Intelligent control for large-scale variable speed variable pitch wind turbines

    Institute of Scientific and Technical Information of China (English)

    Xinfang ZHANG; Daping XU; Yibing LIU

    2004-01-01

    Large-scale wind turbine generator systems have strong nonlinear multivariable characteristics with many uncertain factors and disturbances.Automatic control is crucial for the efficiency and reliability of wind turbines.On the basis of simplified and proper model of variable speed variable pitch wind turbines,the effective wind speed is estimated using extended Kalman filter.Intelligent control schemes proposed in the paper include two loops which operate in synchronism with each other.At below-rated wind speed,the inner loop adopts adaptive fuzzy control based on variable universe for generator torque regulation to realize maximum wind energy capture.At above-rated wind speed, a controller based on least square support vector machine is proposed to adjust pitch angle and keep rated output power.The simulation shows the effectiveness of the intelligent control.

  3. AIC identifies optimal representation of longitudinal dietary variables.

    Science.gov (United States)

    VanBuren, John; Cavanaugh, Joseph; Marshall, Teresa; Warren, John; Levy, Steven M

    2017-09-01

    The Akaike Information Criterion (AIC) is a well-known tool for variable selection in multivariable modeling as well as a tool to help identify the optimal representation of explanatory variables. However, it has been discussed infrequently in the dental literature. The purpose of this paper is to demonstrate the use of AIC in determining the optimal representation of dietary variables in a longitudinal dental study. The Iowa Fluoride Study enrolled children at birth and dental examinations were conducted at ages 5, 9, 13, and 17. Decayed or filled surfaces (DFS) trend clusters were created based on age 13 DFS counts and age 13-17 DFS increments. Dietary intake data (water, milk, 100 percent-juice, and sugar sweetened beverages) were collected semiannually using a food frequency questionnaire. Multinomial logistic regression models were fit to predict DFS cluster membership (n=344). Multiple approaches could be used to represent the dietary data including averaging across all collected surveys or over different shorter time periods to capture age-specific trends or using the individual time points of dietary data. AIC helped identify the optimal representation. Averaging data for all four dietary variables for the whole period from age 9.0 to 17.0 provided a better representation in the multivariable full model (AIC=745.0) compared to other methods assessed in full models (AICs=750.6 for age 9 and 9-13 increment dietary measurements and AIC=762.3 for age 9, 13, and 17 individual measurements). The results illustrate that AIC can help researchers identify the optimal way to summarize information for inclusion in a statistical model. The method presented here can be used by researchers performing statistical modeling in dental research. This method provides an alternative approach for assessing the propriety of variable representation to significance-based procedures, which could potentially lead to improved research in the dental community. © 2017 American

  4. Comparison of variability in pork carcass composition and quality between barrows and gilts.

    Science.gov (United States)

    Overholt, M F; Arkfeld, E K; Mohrhauser, D A; King, D A; Wheeler, T L; Dilger, A C; Shackelford, S D; Boler, D D

    2016-10-01

    Pigs ( = 8,042) raised in 8 different barns representing 2 seasons (cold and hot) and 2 production focuses (lean growth and meat quality) were used to characterize variability of carcass composition and quality traits between barrows and gilts. Data were collected on 7,684 pigs at the abattoir. Carcass characteristics, subjective loin quality, and fresh ham face color (muscles) were measured on a targeted 100% of carcasses. Fresh belly characteristics, boneless loin weight, instrumental loin color, and ultimate loin pH measurements were collected from 50% of the carcasses each slaughter day. Adipose tissue iodine value (IV), 30-min loin pH, LM slice shear force, and fresh ham muscle characteristic measurements were recorded on 10% of carcasses each slaughter day. Data were analyzed using the MIXED procedure of SAS as a 1-way ANOVA in a randomized complete block design with 2 levels (barrows and gilts). Barn (block), marketing group, production focus, and season were random variables. A 2-variance model was fit using the REPEATED statement of the MIXED procedure, grouped by sex for analysis of least squares means. Homogeneity of variance was tested on raw data using Levene's test of the GLM procedure. Hot carcass weight of pigs (94.6 kg) in this study was similar to U.S. industry average HCW (93.1 kg). Therefore, these data are representative of typical U.S. pork carcasses. There was no difference ( ≥ 0.09) in variability of HCW or loin depth between barrow and gilt carcasses. Back fat depth and estimated carcass lean were more variable ( ≤ 0.0001) and IV was less variable ( = 0.05) in carcasses from barrows than in carcasses from gilts. Fresh belly weight and thickness were more variable ( ≤ 0.01) for bellies of barrows than bellies of gilts, but there was no difference in variability for belly length, width, or flop distance ( ≥ 0.06). Fresh loin subjective color was less variable ( ham traits. Overall, traits associated with carcass fatness, including

  5. Spontaneous temporal changes and variability of peripheral nerve conduction analyzed using a random effects model

    DEFF Research Database (Denmark)

    Krøigård, Thomas; Gaist, David; Otto, Marit

    2014-01-01

    SUMMARY: The reproducibility of variables commonly included in studies of peripheral nerve conduction in healthy individuals has not previously been analyzed using a random effects regression model. We examined the temporal changes and variability of standard nerve conduction measures in the leg...... reexamined after 2 and 26 weeks. There was no change in the variables except for a minor decrease in sural nerve sensory action potential amplitude and a minor increase in tibial nerve minimal F-wave latency. Reproducibility was best for peroneal nerve distal motor latency and motor conduction velocity......, sural nerve sensory conduction velocity, and tibial nerve minimal F-wave latency. Between-subject variability was greater than within-subject variability. Sample sizes ranging from 21 to 128 would be required to show changes twice the magnitude of the spontaneous changes observed in this study. Nerve...

  6. Final Technical Report: Low-Cost Solar Variability Sensors for Ubiquitous Deployment.

    Energy Technology Data Exchange (ETDEWEB)

    Lave, Matthew Samuel [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2016-01-01

    In this project, an integrated solution to measuring and collecting solar variability data called the solar variability datalogger (SVD) was developed, tested, and the value of its data to distribution grid integration studies was demonstrated. This work addressed the problem that high-frequency solar variability is rarely measured – due to the high cost and complex installation of existing solar irradiance measuring pyranometers – but is critical to the accurate determination of the impact of photovoltaics to electric grid operation. For example, up to a 300% difference in distribution grid voltage regulator tap change operations (a measure of the impact of PV) [1] has been observed due solely to different solar variability profiles.

  7. [Mother-newborn relational risk - Study of prevalence and associated variables].

    Science.gov (United States)

    Muñoz, Maribel; Poo, Ana María; Baeza, Bernardita; Bustos, M Luis

    2015-01-01

    Clinical evidence reveals the importance of mother-newborn bonding experience for health promoting and maintenance of human life. If the newborn lacks care and affection, she/he may develop an attachment disorder. A predictive scale regarding the risk of mothernewborn relationships is available, which makes possible an early intervention to prevent the development of relational disorders. The aim of this study is to apply the Kimelman measurement scale to determine the relational risk in mother-newborn pairs, as well as the prevalence and the associated biopsychosocial variables. A cross-sectional study with a probabilistic sample of 333 mother-infant pairs in postpartum maternity at Temuco hospital. The Kimelman mother-newborn attachment assessment guide was used. Biopsychosocial variables were obtained from the mothers studied. The association of biopsychosocial variables with relational risk was analyzed using OR and confidence intervals of 95%. The prevalence of high relational risk was 43.8%. The associated biopsychosocial variables included, women with no steady partner, single parent, teenage mothers, unwanted and unplanned pregnancy. Almost half of the mothers were in the high risk group. Early identification of relational risk and its related variables could help in the intervention in this vulnerable group. Copyright © 2015. Publicado por Elsevier España, S.L.U.

  8. Evidence for a time-invariant phase variable in human ankle control.

    Directory of Open Access Journals (Sweden)

    Robert D Gregg

    Full Text Available Human locomotion is a rhythmic task in which patterns of muscle activity are modulated by state-dependent feedback to accommodate perturbations. Two popular theories have been proposed for the underlying embodiment of phase in the human pattern generator: a time-dependent internal representation or a time-invariant feedback representation (i.e., reflex mechanisms. In either case the neuromuscular system must update or represent the phase of locomotor patterns based on the system state, which can include measurements of hundreds of variables. However, a much simpler representation of phase has emerged in recent designs for legged robots, which control joint patterns as functions of a single monotonic mechanical variable, termed a phase variable. We propose that human joint patterns may similarly depend on a physical phase variable, specifically the heel-to-toe movement of the Center of Pressure under the foot. We found that when the ankle is unexpectedly rotated to a position it would have encountered later in the step, the Center of Pressure also shifts forward to the corresponding later position, and the remaining portion of the gait pattern ensues. This phase shift suggests that the progression of the stance ankle is controlled by a biomechanical phase variable, motivating future investigations of phase variables in human locomotor control.

  9. Commentary on guidelines for radiation measurement and treatment of substances including naturally occurring radioactive materials

    International Nuclear Information System (INIS)

    Sakurai, Naoyuki; Ishiguro, Hideharu

    2007-01-01

    Study group on safety regulation on research reactors in Ministry of Education, Culture, Sports, Science and Technology (MEXT) reported the guidelines of 'Guidelines on radiation measurement and treatment of naturally occurring radioactive materials (NORM)' on 6 February 2006. RANDEC made the website contents 'Study on use and safety of the substances including uranium or thorium', based on the contract with MEXT to make theirs contents. This paper describes the outline of the website in MEXT homepage, background and contents of NORM guidelines in order to understand easily and visually the NORM guidelines, adding in some flowcharts and figures. (author)

  10. Determining the Ocean's Role on the Variable Gravity Field on Earth Rotation

    Science.gov (United States)

    Ponte, Rui M.

    1999-01-01

    A number of ocean models of different complexity have been used to study changes in the oceanic mass field and angular momentum and their relation to the variable Earth rotation and gravity field. Time scales examined range from seasonal to a few days. Results point to the importance of oceanic signals in driving polar motion, in particular the Chandler and annual wobbles. Results also show that oceanic signals have a measurable impact on length-of-day variations. Various circulation features and associated mass signals, including the North Pacific subtropical gyre, the equatorial currents, and the Antarctic Circumpolar Current play a significant role in oceanic angular momentum variability.

  11. Measuring Networking as an Outcome Variable in Undergraduate Research Experiences.

    Science.gov (United States)

    Hanauer, David I; Hatfull, Graham

    2015-01-01

    The aim of this paper is to propose, present, and validate a simple survey instrument to measure student conversational networking. The tool consists of five items that cover personal and professional social networks, and its basic principle is the self-reporting of degrees of conversation, with a range of specific discussion partners. The networking instrument was validated in three studies. The basic psychometric characteristics of the scales were established by conducting a factor analysis and evaluating internal consistency using Cronbach's alpha. The second study used a known-groups comparison and involved comparing outcomes for networking scales between two different undergraduate laboratory courses (one involving a specific effort to enhance networking). The final study looked at potential relationships between specific networking items and the established psychosocial variable of project ownership through a series of binary logistic regressions. Overall, the data from the three studies indicate that the networking scales have high internal consistency (α = 0.88), consist of a unitary dimension, can significantly differentiate between research experiences with low and high networking designs, and are related to project ownership scales. The ramifications of the networking instrument for student retention, the enhancement of public scientific literacy, and the differentiation of laboratory courses are discussed. © 2015 D. I. Hanauer and G. Hatfull. CBE—Life Sciences Education © 2015 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  12. Measure theory and fine properties of functions

    CERN Document Server

    Evans, Lawrence Craig

    2015-01-01

    Measure Theory and Fine Properties of Functions, Revised Edition provides a detailed examination of the central assertions of measure theory in n-dimensional Euclidean space. The book emphasizes the roles of Hausdorff measure and capacity in characterizing the fine properties of sets and functions. Topics covered include a quick review of abstract measure theory, theorems and differentiation in ℝn, Hausdorff measures, area and coarea formulas for Lipschitz mappings and related change-of-variable formulas, and Sobolev functions as well as functions of bounded variation.The text provides complete proofs of many key results omitted from other books, including Besicovitch's covering theorem, Rademacher's theorem (on the differentiability a.e. of Lipschitz functions), area and coarea formulas, the precise structure of Sobolev and BV functions, the precise structure of sets of finite perimeter, and Aleksandrov's theorem (on the twice differentiability a.e. of convex functions).This revised edition includes countl...

  13. The variability of interconnected wind plants

    International Nuclear Information System (INIS)

    Katzenstein, Warren; Fertig, Emily; Apt, Jay

    2010-01-01

    We present the first frequency-dependent analyses of the geographic smoothing of wind power's variability, analyzing the interconnected measured output of 20 wind plants in Texas. Reductions in variability occur at frequencies corresponding to times shorter than ∼24 h and are quantified by measuring the departure from a Kolmogorov spectrum. At a frequency of 2.8x10 -4 Hz (corresponding to 1 h), an 87% reduction of the variability of a single wind plant is obtained by interconnecting 4 wind plants. Interconnecting the remaining 16 wind plants produces only an additional 8% reduction. We use step change analyses and correlation coefficients to compare our results with previous studies, finding that wind power ramps up faster than it ramps down for each of the step change intervals analyzed and that correlation between the power output of wind plants 200 km away is half that of co-located wind plants. To examine variability at very low frequencies, we estimate yearly wind energy production in the Great Plains region of the United States from automated wind observations at airports covering 36 years. The estimated wind power has significant inter-annual variability and the severity of wind drought years is estimated to be about half that observed nationally for hydroelectric power.

  14. Reliability of Wearable Inertial Measurement Units to Measure Physical Activity in Team Handball.

    Science.gov (United States)

    Luteberget, Live S; Holme, Benjamin R; Spencer, Matt

    2018-04-01

    To assess the reliability and sensitivity of commercially available inertial measurement units to measure physical activity in team handball. Twenty-two handball players were instrumented with 2 inertial measurement units (OptimEye S5; Catapult Sports, Melbourne, Australia) taped together. They participated in either a laboratory assessment (n = 10) consisting of 7 team handball-specific tasks or field assessment (n = 12) conducted in 12 training sessions. Variables, including PlayerLoad™ and inertial movement analysis (IMA) magnitude and counts, were extracted from the manufacturers' software. IMA counts were divided into intensity bands of low (1.5-2.5 m·s -1 ), medium (2.5-3.5 m·s -1 ), high (>3.5 m·s -1 ), medium/high (>2.5 m·s -1 ), and total (>1.5 m·s -1 ). Reliability between devices and sensitivity was established using coefficient of variation (CV) and smallest worthwhile difference (SWD). Laboratory assessment: IMA magnitude showed a good reliability (CV = 3.1%) in well-controlled tasks. CV increased (4.4-6.7%) in more-complex tasks. Field assessment: Total IMA counts (CV = 1.8% and SWD = 2.5%), PlayerLoad (CV = 0.9% and SWD = 2.1%), and their associated variables (CV = 0.4-1.7%) showed a good reliability, well below the SWD. However, the CV of IMA increased when categorized into intensity bands (2.9-5.6%). The reliability of IMA counts was good when data were displayed as total, high, or medium/high counts. A good reliability for PlayerLoad and associated variables was evident. The CV of the previously mentioned variables was well below the SWD, suggesting that OptimEye's inertial measurement unit and its software are sensitive for use in team handball.

  15. Risk assessment of groundwater level variability using variable Kriging methods

    Science.gov (United States)

    Spanoudaki, Katerina; Kampanis, Nikolaos A.

    2015-04-01

    Assessment of the water table level spatial variability in aquifers provides useful information regarding optimal groundwater management. This information becomes more important in basins where the water table level has fallen significantly. The spatial variability of the water table level in this work is estimated based on hydraulic head measured during the wet period of the hydrological year 2007-2008, in a sparsely monitored basin in Crete, Greece, which is of high socioeconomic and agricultural interest. Three Kriging-based methodologies are elaborated in Matlab environment to estimate the spatial variability of the water table level in the basin. The first methodology is based on the Ordinary Kriging approach, the second involves auxiliary information from a Digital Elevation Model in terms of Residual Kriging and the third methodology calculates the probability of the groundwater level to fall below a predefined minimum value that could cause significant problems in groundwater resources availability, by means of Indicator Kriging. The Box-Cox methodology is applied to normalize both the data and the residuals for improved prediction results. In addition, various classical variogram models are applied to determine the spatial dependence of the measurements. The Matérn model proves to be the optimal, which in combination with Kriging methodologies provides the most accurate cross validation estimations. Groundwater level and probability maps are constructed to examine the spatial variability of the groundwater level in the basin and the associated risk that certain locations exhibit regarding a predefined minimum value that has been set for the sustainability of the basin's groundwater resources. Acknowledgement The work presented in this paper has been funded by the Greek State Scholarships Foundation (IKY), Fellowships of Excellence for Postdoctoral Studies (Siemens Program), 'A simulation-optimization model for assessing the best practices for the

  16. The Beast of Aggregating Cognitive Load Measures in Technology-Based Learning

    Science.gov (United States)

    Leppink, Jimmie; van Merriënboer, Jeroen J. G.

    2015-01-01

    An increasing part of cognitive load research in technology-based learning includes a component of repeated measurements, that is: participants are measured two or more times on the same performance, mental effort or other variable of interest. In many cases, researchers aggregate scores obtained from repeated measurements to one single sum or…

  17. Interobserver variability in visual evaluation of thoracic CT scans and comparison with automatic computer measurements of CT lung density

    DEFF Research Database (Denmark)

    Winkler Wille, Mathilde Marie; Thomsen, Laura Hohwü; Dirksen, Asger

    2012-01-01

    lung density measurements, i.e. densitometry. Methods – In a pilot study 60 CT scans were selected from a sample of 3980 CT scans from The Danish Lung Cancer Screening Trial (DLCST). The amount of emphysema in these scans was scored independently by two observers, who were blinded regarding clinical...... information. The lung was segmented automatically by in-house developed computer software, and the percentage of pixels below -950 HU was used as a surrogate marker for emphysema. The observer variability, as well as the correlation with the lung density measurements, was analysed using Spearman’s rank...... in emphysema grading. However, the agreement with the CT lung density measurement was poor, indicating that the two types of evaluation represent different aspects of emphysema. Most likely, they should be seen as complementary rather than competitive evaluations. Future comparison with physiological tests...

  18. Changes in the Complexity of Heart Rate Variability with Exercise Training Measured by Multiscale Entropy-Based Measurements

    Directory of Open Access Journals (Sweden)

    Frederico Sassoli Fazan

    2018-01-01

    Full Text Available Quantifying complexity from heart rate variability (HRV series is a challenging task, and multiscale entropy (MSE, along with its variants, has been demonstrated to be one of the most robust approaches to achieve this goal. Although physical training is known to be beneficial, there is little information about the long-term complexity changes induced by the physical conditioning. The present study aimed to quantify the changes in physiological complexity elicited by physical training through multiscale entropy-based complexity measurements. Rats were subject to a protocol of medium intensity training ( n = 13 or a sedentary protocol ( n = 12 . One-hour HRV series were obtained from all conscious rats five days after the experimental protocol. We estimated MSE, multiscale dispersion entropy (MDE and multiscale SDiff q from HRV series. Multiscale SDiff q is a recent approach that accounts for entropy differences between a given time series and its shuffled dynamics. From SDiff q , three attributes (q-attributes were derived, namely SDiff q m a x , q m a x and q z e r o . MSE, MDE and multiscale q-attributes presented similar profiles, except for SDiff q m a x . q m a x showed significant differences between trained and sedentary groups on Time Scales 6 to 20. Results suggest that physical training increases the system complexity and that multiscale q-attributes provide valuable information about the physiological complexity.

  19. Small-scale variability in tropical tropopause layer humidity

    Science.gov (United States)

    Jensen, E. J.; Ueyama, R.; Pfister, L.; Karcher, B.; Podglajen, A.; Diskin, G. S.; DiGangi, J. P.; Thornberry, T. D.; Rollins, A. W.; Bui, T. V.; Woods, S.; Lawson, P.

    2016-12-01

    Recent advances in statistical parameterizations of cirrus cloud processes for use in global models are highlighting the need for information about small-scale fluctuations in upper tropospheric humidity and the physical processes that control the humidity variability. To address these issues, we have analyzed high-resolution airborne water vapor measurements obtained in the Airborne Tropical TRopopause EXperiment over the tropical Pacific between 14 and 20 km. Using accurate and precise 1-Hz water vapor measurements along approximately-level aircraft flight legs, we calculate structure functions spanning horizontal scales ranging from about 0.2 to 50 km, and we compare the water vapor variability in the lower (about 14 km) and upper (16-19 km) Tropical Tropopause Layer (TTL). We also compare the magnitudes and scales of variability inside TTL cirrus versus in clear-sky regions. The measurements show that in the upper TTL, water vapor concentration variance is stronger inside cirrus than in clear-sky regions. Using simulations of TTL cirrus formation, we show that small variability in clear-sky humidity is amplified by the strong sensitivity of ice nucleation rate to supersaturation, which results in highly-structured clouds that subsequently drive variability in the water vapor field. In the lower TTL, humidity variability is correlated with recent detrainment from deep convection. The structure functions indicate approximately power-law scaling with spectral slopes ranging from about -5/3 to -2.

  20. Hidden variables and locality in quantum theory

    International Nuclear Information System (INIS)

    Shiva, Vandana.

    1978-12-01

    The status of hidden variables in quantum theory has been debated since the 1920s. The author examines the no-hidden-variable theories of von Neumann, Kochen, Specker and Bell, and finds that they all share one basic assumption: averaging over the hidden variables should reproduce the quantum mechanical probabilities. Von Neumann also makes a linearity assumption, Kochen and Specker require the preservation of certain functional relations between magnitudes, and Bell proposes a locality condition. It has been assumed that the extrastatistical requirements are needed to serve as criteria of success for the introduction of hidden variables because the statistical condition is trivially satisfied, and that Bell's result is based on a locality condition that is physically motivated. The author shows that the requirement of weak locality, which is not physically motivated, is enough to give Bell's result. The proof of Bell's inequality works equally well for any pair of commuting magnitudes satisfying a condition called the degeneracy principle. None of the no-hidden-variable proofs apply to a class of hidden variable theories that are not phase-space reconstructions of quantum mechanics. The author discusses one of these theories, the Bohm-Bub theory, and finds that hidden variable theories that re all the quantum statistics, for single and sequential measurements, must introduce a randomization process for the hidden variables after each measurement. The philosophical significance of this theory lies in the role it can play in solving the conceptual puzzles posed by quantum theory

  1. Heart rate variability and swimming.

    Science.gov (United States)

    Koenig, Julian; Jarczok, Marc N; Wasner, Mieke; Hillecke, Thomas K; Thayer, Julian F

    2014-10-01

    Professionals in the domain of swimming have a strong interest in implementing research methods in evaluating and improving training methods to maximize athletic performance and competitive outcome. Heart rate variability (HRV) has gained attention in research on sport and exercise to assess autonomic nervous system activity underlying physical activity and sports performance. Studies on swimming and HRV are rare. This review aims to summarize the current evidence on the application of HRV in swimming research and draws implications for future research. A systematic search of databases (PubMed via MEDLINE, PSYNDEX and Embase) according to the PRISMA statement was employed. Studies were screened for eligibility on inclusion criteria: (a) empirical investigation (HRV) in humans (non-clinical); (b) related to swimming; (c) peer-reviewed journal; and (d) English language. The search revealed 194 studies (duplicates removed), of which the abstract was screened for eligibility. Fourteen studies meeting the inclusion criteria were included in the review. Included studies broadly fell into three classes: (1) control group designs to investigate between-subject differences (i.e. swimmers vs. non-swimmers, swimmers vs. other athletes); (2) repeated measures designs on within-subject differences of interventional studies measuring HRV to address different modalities of training or recovery; and (3) other studies, on the agreement of HRV with other measures. The feasibility and possibilities of HRV within this particular field of application are well documented within the existing literature. Future studies, focusing on translational approaches that transfer current evidence in general practice (i.e. training of athletes) are needed.

  2. Reproducibility of heart rate variability parameters measured in healthy subjects at rest and after a postural change maneuver

    Directory of Open Access Journals (Sweden)

    E.M. Dantas

    2010-10-01

    Full Text Available Heart rate variability (HRV provides important information about cardiac autonomic modulation. Since it is a noninvasive and inexpensive method, HRV has been used to evaluate several parameters of cardiovascular health. However, the internal reproducibility of this method has been challenged in some studies. Our aim was to determine the intra-individual reproducibility of HRV parameters in short-term recordings obtained in supine and orthostatic positions. Electrocardiographic (ECG recordings were obtained from 30 healthy subjects (20-49 years, 14 men using a digital apparatus (sampling ratio = 250 Hz. ECG was recorded for 10 min in the supine position and for 10 min in the orthostatic position. The procedure was repeated 2-3 h later. Time and frequency domain analyses were performed. Frequency domain included low (LF, 0.04-0.15 Hz and high frequency (HF, 0.15-0.4 Hz bands. Power spectral analysis was performed by the autoregressive method and model order was set at 16. Intra-subject agreement was assessed by linear regression analysis, test of difference in variances and limits of agreement. Most HRV measures (pNN50, RMSSD, LF, HF, and LF/HF ratio were reproducible independent of body position. Better correlation indexes (r > 0.6 were obtained in the orthostatic position. Bland-Altman plots revealed that most values were inside the agreement limits, indicating concordance between measures. Only SDNN and NNv in the supine position were not reproducible. Our results showed reproducibility of HRV parameters when recorded in the same individual with a short time between two exams. The increased sympathetic activity occurring in the orthostatic position probably facilitates reproducibility of the HRV indexes.

  3. Sources of variability of resting cerebral blood flow in healthy subjects

    DEFF Research Database (Denmark)

    Henriksen, Otto Mølby; Kruuse, Christina Rostrup; Olesen, Jes

    2013-01-01

    Measurements of cerebral blood flow (CBF) show large variability among healthy subjects. The aim of the present study was to investigate the relative effect of established factors influencing CBF on the variability of resting CBF. We retrospectively analyzed spontaneous variability in 430 CBF...... measurements acquired in 152 healthy, young subjects using (133)Xe single-photon emission computed tomography. Cerebral blood flow was correlated positively with both end-tidal expiratory PCO2 (PETCO2) and female gender and inversely with hematocrit (Hct). Between- and within-subject CO2 reactivity...... when Hct was also accounted for. The present study confirms large between-subject variability in CBF measurements and that gender, Hct, and PETCO2 explain only a small part of this variability. This implies that a large fraction of CBF variability may be due to unknown factors such as differences...

  4. Compact range for variable-zone measurements

    Science.gov (United States)

    Burnside, Walter D.; Rudduck, Roger C.; Yu, Jiunn S.

    1988-08-02

    A compact range for testing antennas or radar targets includes a source for directing energy along a feedline toward a parabolic reflector. The reflected wave is a spherical wave with a radius dependent on the distance of the source from the focal point of the reflector.

  5. Variability in large-scale wind power generation

    DEFF Research Database (Denmark)

    Kiviluoma, Juha; Holttinen, Hannele; Weir, David

    2016-01-01

    The paper demonstrates the characteristics of wind power variability and net load variability in multiple power systems based on real data from multiple years. Demonstrated characteristics include probability distribution for different ramp durations, seasonal and diurnal variability and low net ...... with well-dispersed wind power. Copyright © 2015 John Wiley & Sons, Ltd....

  6. Mechanics of deformations in terms of scalar variables

    Science.gov (United States)

    Ryabov, Valeriy A.

    2017-05-01

    Theory of particle and continuous mechanics is developed which allows a treatment of pure deformation in terms of the set of variables "coordinate-momentum-force" instead of the standard treatment in terms of tensor-valued variables "strain-stress." This approach is quite natural for a microscopic description of atomic system, according to which only pointwise forces caused by the stress act to atoms making a body deform. The new concept starts from affine transformation of spatial to material coordinates in terms of the stretch tensor or its analogs. Thus, three principal stretches and three angles related to their orientation form a set of six scalar variables to describe deformation. Instead of volume-dependent potential used in the standard theory, which requires conditions of equilibrium for surface and body forces acting to a volume element, a potential dependent on scalar variables is introduced. A consistent introduction of generalized force associated with this potential becomes possible if a deformed body is considered to be confined on the surface of torus having six genuine dimensions. Strain, constitutive equations and other fundamental laws of the continuum and particle mechanics may be neatly rewritten in terms of scalar variables. Giving a new presentation for finite deformation new approach provides a full treatment of hyperelasticity including anisotropic case. Derived equations of motion generate a new kind of thermodynamical ensemble in terms of constant tension forces. In this ensemble, six internal deformation forces proportional to the components of Irving-Kirkwood stress are controlled by applied external forces. In thermodynamical limit, instead of the pressure and volume as state variables, this ensemble employs deformation force measured in kelvin unit and stretch ratio.

  7. Measurements for testing of fluoroscopic screens, including the photofluorographic units

    International Nuclear Information System (INIS)

    Balfanz, R.

    1986-01-01

    Image quality control measurements for fluoroscopic screens and photofluorographs have shown that both types of equipment have a long operating life, so that constancy and technical performance tests are absolutely necessary. It is recommended to conclude in-service maintenance contracts with the manufacturers. (DG) [de

  8. Maximizing Energy Capture of Fixed-Pitch Variable-Speed Wind Turbines

    Energy Technology Data Exchange (ETDEWEB)

    Pierce, K.; Migliore, P.

    2000-08-01

    Field tests of a variable-speed, stall-regulated wind turbine were conducted at a US Department of Energy Laboratory. A variable-speed generating system, comprising a doubly-fed generator and series-resonant power converter, was installed on a 275-kW, downwind, two-blade wind turbine. Gearbox, generator, and converter efficiency were measured in the laboratory so that rotor aerodynamic efficiency could be determined from field measurement of generator power. The turbine was operated at several discrete rotational speeds to develop power curves for use in formulating variable-speed control strategies. Test results for fixed-speed and variable-speed operation are presented along with discussion and comparison of the variable-speed control methodologies. Where possible, comparisons between fixed-speed and variable-speed operation are shown.

  9. Estimation of intra-operator variability in perfusion parameter measurements using DCE-US.

    Science.gov (United States)

    Gauthier, Marianne; Leguerney, Ingrid; Thalmensi, Jessie; Chebil, Mohamed; Parisot, Sarah; Peronneau, Pierre; Roche, Alain; Lassau, Nathalie

    2011-03-28

    To investigate intra-operator variability of semi-quantitative perfusion parameters using dynamic contrast-enhanced ultrasonography (DCE-US), following bolus injections of SonoVue(®). The in vitro experiments were conducted using three in-house sets up based on pumping a fluid through a phantom placed in a water tank. In the in vivo experiments, B16F10 melanoma cells were xenografted to five nude mice. Both in vitro and in vivo, images were acquired following bolus injections of the ultrasound contrast agent SonoVue(®) (Bracco, Milan, Italy) and using a Toshiba Aplio(®) ultrasound scanner connected to a 2.9-5.8 MHz linear transducer (PZT, PLT 604AT probe) (Toshiba, Japan) allowing harmonic imaging ("Vascular Recognition Imaging") involving linear raw data. A mathematical model based on the dye-dilution theory was developed by the Gustave Roussy Institute, Villejuif, France and used to evaluate seven perfusion parameters from time-intensity curves. Intra-operator variability analyses were based on determining perfusion parameter coefficients of variation (CV). In vitro, different volumes of SonoVue(®) were tested with the three phantoms: intra-operator variability was found to range from 2.33% to 23.72%. In vivo, experiments were performed on tumor tissues and perfusion parameters exhibited values ranging from 1.48% to 29.97%. In addition, the area under the curve (AUC) and the area under the wash-out (AUWO) were two of the parameters of great interest since throughout in vitro and in vivo experiments their variability was lower than 15.79%. AUC and AUWO appear to be the most reliable parameters for assessing tumor perfusion using DCE-US as they exhibited the lowest CV values.

  10. Neurocognitive functioning as an intermediary variable between psychopathology and insight in schizophrenia.

    Science.gov (United States)

    Hwang, Samuel Suk-Hyun; Ahn, Yong Min; Kim, Yong Sik

    2015-12-30

    Based on the neuropsychological deficit model of insight in schizophrenia, we constructed exploratory prediction models for insight, designating neurocognitive measures as the intermediary variables between psychopathology and insight into patients with schizophrenia. The models included the positive, negative, and autistic preoccupation symptoms as primary predictors, and activation symptoms as an intermediary variable for insight. Fifty-six Korean patients, in the acute stage of schizophrenia, completed the Positive and Negative Syndrome Scale, as well as a comprehensive neurocognitive battery of tests at the baseline, 8-weeks, and 1-year follow-ups. Among the neurocognitive measures, the Korean Wechsler Adult Intelligence Scale (K-WAIS) picture arrangement, Controlled Oral Word Association Test (COWAT) perseverative response, and the Continuous Performance Test (CPT) standard error of reaction time showed significant correlations with the symptoms and the insight. When these measures were fitted into the model as intermediaries between the symptoms and the insight, only the perseverative response was found to have a partial mediating effect - both cross-sectionally, and in the 8-week longitudinal change. Overall, the relationship between insight and neurocognitive functioning measures was found to be selective and weak. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. 12 YEARS OF X-RAY VARIABILITY IN M31 GLOBULAR CLUSTERS, INCLUDING 8 BLACK HOLE CANDIDATES, AS SEEN BY CHANDRA

    International Nuclear Information System (INIS)

    Barnard, R.; Garcia, M.; Murray, S. S.

    2012-01-01

    We examined 134 Chandra observations of the population of X-ray sources associated with globular clusters (GCs) in the central region of M31. These are expected to be X-ray binary systems (XBs), consisting of a neutron star or black hole accreting material from a close companion. We created long-term light curves for these sources, correcting for background, interstellar absorption, and instrumental effects. We tested for variability by examining the goodness of fit for the best-fit constant intensity. We also created structure functions (SFs) for every object in our sample, the first time this technique has been applied to XBs. We found significant variability in 28 out of 34 GCs and GC candidates; the other 6 sources had 0.3-10 keV luminosities fainter than ∼2 × 10 36 erg s –1 , limiting our ability to detect similar variability. The SFs of XBs with 0.3-10 keV luminosities ∼2-50 × 10 36 erg s –1 generally showed considerably more variability than the published ensemble SF of active galactic nuclei (AGNs). Our brightest XBs were mostly consistent with the AGN SF; however, their 2-10 keV fluxes could be matched by <1 AGN per square degree. These encouraging results suggest that examining the long-term light curves of other X-ray sources in the field may provide an important distinction between X-ray binaries and background galaxies, as the X-ray emission spectra from these two classes of X-ray sources are similar. Additionally, we identify 3 new black hole candidates (BHCs) using additional XMM-Newton data, bringing the total number of M31 GC BHCs to 9, with 8 covered in this survey.

  12. Differential turbidity measurements at Hanford

    International Nuclear Information System (INIS)

    Laulainen, N.S.; Bates, J.A.; Kleckner, E.W.; Michalsky, J.J.; Schrotke, P.M.; Thorp, J.M.

    1978-01-01

    An experiment to exmine differential turbidity effects on measured insolation between the Rattlesnake Observatory and the Hanford Meteorological Station was conducted during summer 1977. Several types of solar radiation instruments were used, including pyranometers, multiwavelength sunphotometers, and an active cavity radiometer. Preliminary results show dramatic temporal variability of aerosol loading at HMS and significant insolation and turbidity differences between the Observatory and HMS

  13. Laser induced breakdown spectroscopy of the uranium including calcium. Time resolved measurement spectroscopic analysis (Contract research)

    International Nuclear Information System (INIS)

    Akaoka, Katsuaki; Maruyama, Youichiro; Oba, Masaki; Miyabe, Masabumi; Otobe, Haruyoshi; Wakaida, Ikuo

    2010-05-01

    For the remote analysis of low DF TRU (Decontamination Factor Transuranic) fuel, Laser Breakdown Spectroscopy (LIBS) was applied to uranium oxide including a small amount of calcium oxide. The characteristics, such as spectrum intensity and plasma excitation temperature, were measured using time-resolved spectroscopy. As a result, in order to obtain the stable intensity of calcium spectrum for the uranium spectrum, it was found out that the optimum observation delay time of spectrum is 4 microseconds or more after laser irradiation. (author)

  14. Soil variability in mountain areas

    OpenAIRE

    Zanini, E.; Freppaz, M.; Stanchi, S.; Bonifacio, E.; Egli, M.

    2015-01-01

    The high spatial variability of soils is a relevant issue at local and global scales, and determines the complexity of soil ecosystem functions and services. This variability derives from strong dependencies of soil ecosystems on parent materials, climate, relief and biosphere, including human impact. Although present in all environments, the interactions of soils with these forming factors are particularly striking in mountain areas.

  15. Variability in human body size

    Science.gov (United States)

    Annis, J. F.

    1978-01-01

    The range of variability found among homogeneous groups is described and illustrated. Those trends that show significantly marked differences between sexes and among a number of racial/ethnic groups are also presented. Causes of human-body size variability discussed include genetic endowment, aging, nutrition, protective garments, and occupation. The information is presented to aid design engineers of space flight hardware and equipment.

  16. [Blood pressure variability: clinical interest or simple curiosity?].

    Science.gov (United States)

    Ciaroni, Stefano

    2007-03-14

    Blood pressure variability is a physiological phenomenon influenced by many internal and external factors. This variability could be also influenced by pathological conditions such as arterial hypertension. Two forms must be mainly distinguished: the blood pressure variability at long and short-term. The latter could only be studied by continuous recordings. In this article will be analysed the interest of measuring blood pressure variability, its cardiovascular prognosis and the therapeutic tools when it is increased.

  17. Compressing the hidden variable space of a qubit

    OpenAIRE

    Montina, Alberto

    2010-01-01

    In previously exhibited hidden variable models of quantum state preparation and measurement, the number of continuous hidden variables describing the actual state of a single realization is never smaller than the quantum state manifold dimension. We introduce a simple model for a qubit whose hidden variable space is one-dimensional, i.e., smaller than the two-dimensional Bloch sphere. The hidden variable probability distributions associated with the quantum states satisfy reasonable criteria ...

  18. Improving Continuous-Variable Measurement-Device-Independent Multipartite Quantum Communication with Optical Amplifiers*

    Science.gov (United States)

    Guo, Ying; Zhao, Wei; Li, Fei; Huang, Duan; Liao, Qin; Xie, Cai-Lang

    2017-08-01

    The developing tendency of continuous-variable (CV) measurement-device-independent (MDI) quantum cryptography is to cope with the practical issue of implementing scalable quantum networks. Up to now, most theoretical and experimental researches on CV-MDI QKD are focused on two-party protocols. However, we suggest a CV-MDI multipartite quantum secret sharing (QSS) protocol use the EPR states coupled with optical amplifiers. More remarkable, QSS is the real application in multipartite CV-MDI QKD, in other words, is the concrete implementation method of multipartite CV-MDI QKD. It can implement a practical quantum network scheme, under which the legal participants create the secret correlations by using EPR states connecting to an untrusted relay via insecure links and applying the multi-entangled Greenberger-Horne-Zeilinger (GHZ) state analysis at relay station. Even if there is a possibility that the relay may be completely tampered, the legal participants are still able to extract a secret key from network communication. The numerical simulation indicates that the quantum network communication can be achieved in an asymmetric scenario, fulfilling the demands of a practical quantum network. Additionally, we illustrate that the use of optical amplifiers can compensate the partial inherent imperfections of detectors and increase the transmission distance of the CV-MDI quantum system.

  19. Alpha-contingent EEG feedback reduces SPECT rCBF variability

    DEFF Research Database (Denmark)

    McLaughlin, Thomas; Steinberg, Bruce; Mulholland, Thomas

    2005-01-01

    EEG feedback methods, which link the occurrence of alpha to the presentation of repeated visual stimuli, reduce the relative variability of subsequent, alpha-blocking event durations. The temporal association between electro-cortical field activation and regional cerebral blood flow (rCBF) led us...... to investigate whether the reduced variability of alpha-blocking durations with feedback is associated with a reduction in rCBF variability. Reduced variability in the rCBF response domain under EEG feedback control might have methodological implications for future brain-imaging studies. Visual stimuli were...... to quantify the variance-reducing effects of ACS across multiple, distributed areas of the brain. Both EEG and rCBF measures demonstrated decreased variability under ACS. This improved control was seen for localized as well as anatomically distributed rCBF measures....

  20. Circulating VEGF as a biological marker in patients with rheumatoid arthritis? Preanalytical and biological variability in healthy persons and in patients

    DEFF Research Database (Denmark)

    Hetland, Merete Lund; Christensen, Ib Jarle; Lottenburger, Tine

    2008-01-01

    /ml (range: non-detectable to 352); serum: 328 pg/ml (53-1791)) were independent of gender and age. Short- and long-term biologic variability included diurnal variation (sampling should take place after 7 AM) and impact of exercise (increased VEGF immediately after bicycling normalised within 1 hour......BACKGROUND: Soluble vascular endothelial growth factor (VEGF) is a promising biomarker in monitoring rheumatoid arthritis (RA), but studies of pre-analytical and biologic variability are few. METHODS: VEGF was measured by ELISA methods in serum and plasma from healthy persons and RA patients. Pre......). CONCLUSIONS: Pre-analytical factors and biologic variability including diurnal variation and impact of exercise should be accounted for in future studies that include circulating VEGF as a biological marker....

  1. Acoustic response variability in automotive vehicles

    Science.gov (United States)

    Hills, E.; Mace, B. R.; Ferguson, N. S.

    2009-03-01

    A statistical analysis of a series of measurements of the audio-frequency response of a large set of automotive vehicles is presented: a small hatchback model with both a three-door (411 vehicles) and five-door (403 vehicles) derivative and a mid-sized family five-door car (316 vehicles). The sets included vehicles of various specifications, engines, gearboxes, interior trim, wheels and tyres. The tests were performed in a hemianechoic chamber with the temperature and humidity recorded. Two tests were performed on each vehicle and the interior cabin noise measured. In the first, the excitation was acoustically induced by sets of external loudspeakers. In the second test, predominantly structure-borne noise was induced by running the vehicle at a steady speed on a rough roller. For both types of excitation, it is seen that the effects of temperature are small, indicating that manufacturing variability is larger than that due to temperature for the tests conducted. It is also observed that there are no significant outlying vehicles, i.e. there are at most only a few vehicles that consistently have the lowest or highest noise levels over the whole spectrum. For the acoustically excited tests, measured 1/3-octave noise reduction levels typically have a spread of 5 dB or so and the normalised standard deviation of the linear data is typically 0.1 or higher. Regarding the statistical distribution of the linear data, a lognormal distribution is a somewhat better fit than a Gaussian distribution for lower 1/3-octave bands, while the reverse is true at higher frequencies. For the distribution of the overall linear levels, a Gaussian distribution is generally the most representative. As a simple description of the response variability, it is sufficient for this series of measurements to assume that the acoustically induced airborne cabin noise is best described by a Gaussian distribution with a normalised standard deviation between 0.09 and 0.145. There is generally

  2. Sources of variability in OSL dose measurements using single grains of quartz

    International Nuclear Information System (INIS)

    Thomsen, K.J.; Murray, A.S.; Boetter-Jensen, L.

    2005-01-01

    In luminescence-based measurements of dose distributions in unheated mineral samples, the observed spread in dose values is usually attributed to four main factors: fluctuations in the number of photons counted, incomplete zeroing of any prior trapped charge (including signals arising from thermal transfer), heterogeneity in dosimetry, and instrument reproducibility. For correct interpretation of measured dose distributions in retrospective dosimetry, it is important to understand the relative importance of these components, and to establish whether other factors also contribute to the observed spread. In this preliminary study, dose distributions have been studied using single grains of heated and laboratory irradiated quartz. By heating the sample, the contribution from incomplete zeroing was excluded and at the same time the sample was sensitised. The laboratory gamma irradiation was designed to deliver a uniform dose to the sample. Thus it was anticipated that statistical fluctuations in the number of photons counted and instrument reproducibility, both quantifiable entities, should be able to account for all the observed variance in the measured dose distributions. We examine this assumption in detail, and discuss the origins and importance of the residual variance in our data

  3. Do spatiotemporal parameters and gait variability differ across the lifespan of healthy adults? A systematic review.

    Science.gov (United States)

    Herssens, Nolan; Verbecque, Evi; Hallemans, Ann; Vereeck, Luc; Van Rompaey, Vincent; Saeys, Wim

    2018-06-12

    Aging is often associated with changes in the musculoskeletal system, peripheral and central nervous system. These age-related changes often result in mobility problems influencing gait performance. Compensatory strategies are used as a way to adapt to these physiological changes. The aim of this review is to investigate the differences in spatiotemporal and gait variability measures throughout the healthy adult life. This systematic review was conducted according to the PRISMA guidelines and registered in the PROSPERO database (no. CRD42017057720). Databases MEDLINE (Pubmed), Web of Science (Web of Knowledge), Cochrane Library and ScienceDirect were systematically searched until March 2018. Eighteen of the 3195 original studies met the eligibility criteria and were included in this review. The majority of studies reported spatiotemporal and gait variability measures in adults above the age of 65, followed by the young adult population, information of middle-aged adults is lacking. Spatiotemporal parameters and gait variability measures were extracted from 2112 healthy adults between 18 and 98 years old and, in general, tend to deteriorate with increasing age. Variability measures were only reported in an elderly population and show great variety between studies. The findings of this review suggest that most spatiotemporal parameters significantly differ across different age groups. Elderly populations show a reduction of preferred walking speed, cadence, step and stride length, all related to a more cautious gait, while gait variability measures remain stable over time. A preliminary framework of normative reference data is provided, enabling insights into the influence of aging on spatiotemporal parameters, however spatiotemporal parameters of middle-aged adults should be investigated more thoroughly. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Variability in carbon exchange of European croplands

    DEFF Research Database (Denmark)

    Eddy J, Moors; Jacobs, Cor; Jans, Wilma

    2010-01-01

    The estimated net ecosystem exchange (NEE) of CO2 based on measurements at 17 flux sites in Europe for 45 cropping periods showed an average loss of -38 gC m-2 per cropping period. The cropping period is defined as the period after sowing or planting until harvest. The variability taken as the st......The estimated net ecosystem exchange (NEE) of CO2 based on measurements at 17 flux sites in Europe for 45 cropping periods showed an average loss of -38 gC m-2 per cropping period. The cropping period is defined as the period after sowing or planting until harvest. The variability taken...... as the standard deviation of these cropping periods was 251 gC m-2. These numbers do not include lateral inputs such as the carbon content of applied manure, nor the carbon exchange out of the cropping period. Both are expected to have a major effect on the C budget of high energy summer crops such as maize. NEE...... and gross primary production (GPP) can be estimated by crop net primary production based on inventories of biomass at these sites, independent of species and regions. NEE can also be estimated by the product of photosynthetic capacity and the number of days with the average air temperature >5 °C. Yield...

  5. Measurement of electrophysical properties in the Landauer-Datta-Lundstrom transport model

    Directory of Open Access Journals (Sweden)

    Юрій Олексійович Кругляк

    2015-04-01

    Full Text Available Experimental methods of measuring the resistance in the frame of the LDL model, including measurements under applied external magnetic field are discussed, namely: method of variable resistor length, four-point measurement scheme, the classical method of the Hall effect measurement and different variants of the van der Pauw method, temperature measurements and accounting for artifacts (Nernst effect, measurements in strong magnetic fields(Shubnikov–deHaaseffect. 

  6. Assessing factors related to waist circumference and obesity: application of a latent variable model.

    Science.gov (United States)

    Dalvand, Sahar; Koohpayehzadeh, Jalil; Karimlou, Masoud; Asgari, Fereshteh; Rafei, Ali; Seifi, Behjat; Niksima, Seyed Hassan; Bakhshi, Enayatollah

    2015-01-01

    Because the use of BMI (Body Mass Index) alone as a measure of adiposity has been criticized, in the present study our aim was to fit a latent variable model to simultaneously examine the factors that affect waist circumference (continuous outcome) and obesity (binary outcome) among Iranian adults. Data included 18,990 Iranian individuals aged 20-65 years that are derived from the third National Survey of Noncommunicable Diseases Risk Factors in Iran. Using latent variable model, we estimated the relation of two correlated responses (waist circumference and obesity) with independent variables including age, gender, PR (Place of Residence), PA (physical activity), smoking status, SBP (Systolic Blood Pressure), DBP (Diastolic Blood Pressure), CHOL (cholesterol), FBG (Fasting Blood Glucose), diabetes, and FHD (family history of diabetes). All variables were related to both obesity and waist circumference (WC). Older age, female sex, being an urban resident, physical inactivity, nonsmoking, hypertension, hypercholesterolemia, hyperglycemia, diabetes, and having family history of diabetes were significant risk factors that increased WC and obesity. Findings from this study of Iranian adult settings offer more insights into factors associated with high WC and high prevalence of obesity in this population.

  7. Assessing Factors Related to Waist Circumference and Obesity: Application of a Latent Variable Model

    Directory of Open Access Journals (Sweden)

    Sahar Dalvand

    2015-01-01

    Full Text Available Background. Because the use of BMI (Body Mass Index alone as a measure of adiposity has been criticized, in the present study our aim was to fit a latent variable model to simultaneously examine the factors that affect waist circumference (continuous outcome and obesity (binary outcome among Iranian adults. Methods. Data included 18,990 Iranian individuals aged 20–65 years that are derived from the third National Survey of Noncommunicable Diseases Risk Factors in Iran. Using latent variable model, we estimated the relation of two correlated responses (waist circumference and obesity with independent variables including age, gender, PR (Place of Residence, PA (physical activity, smoking status, SBP (Systolic Blood Pressure, DBP (Diastolic Blood Pressure, CHOL (cholesterol, FBG (Fasting Blood Glucose, diabetes, and FHD (family history of diabetes. Results. All variables were related to both obesity and waist circumference (WC. Older age, female sex, being an urban resident, physical inactivity, nonsmoking, hypertension, hypercholesterolemia, hyperglycemia, diabetes, and having family history of diabetes were significant risk factors that increased WC and obesity. Conclusions. Findings from this study of Iranian adult settings offer more insights into factors associated with high WC and high prevalence of obesity in this population.

  8. Measurement and structural relations of an authoritative school climate model: A multi-level latent variable investigation.

    Science.gov (United States)

    Konold, Timothy R; Cornell, Dewey

    2015-12-01

    This study tested a conceptual model of school climate in which two key elements of an authoritative school, structure and support variables, are associated with student engagement in school and lower levels of peer aggression. Multilevel multivariate structural modeling was conducted in a statewide sample of 48,027 students in 323 public high schools who completed the Authoritative School Climate Survey. As hypothesized, two measures of structure (Disciplinary Structure and Academic Expectations) and two measures of support (Respect for Students and Willingness to Seek Help) were associated with higher student engagement (Affective Engagement and Cognitive Engagement) and lower peer aggression (Prevalence of Teasing and Bullying) on both student and school levels of analysis, controlling for the effects of school demographics (school size, percentage of minority students, and percentage of low income students). These results support the extension of authoritative school climate model to high school and guide further research on the conditions for a positive school climate. Copyright © 2015 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  9. Variable Selection Strategies for Small-area Estimation Using FIA Plots and Remotely Sensed Data

    Science.gov (United States)

    Andrew Lister; Rachel Riemann; James Westfall; Mike Hoppus

    2005-01-01

    The USDA Forest Service's Forest Inventory and Analysis (FIA) unit maintains a network of tens of thousands of georeferenced forest inventory plots distributed across the United States. Data collected on these plots include direct measurements of tree diameter and height and other variables. We present a technique by which FIA plot data and coregistered...

  10. Improved sample size determination for attributes and variables sampling

    International Nuclear Information System (INIS)

    Stirpe, D.; Picard, R.R.

    1985-01-01

    Earlier INMM papers have addressed the attributes/variables problem and, under conservative/limiting approximations, have reported analytical solutions for the attributes and variables sample sizes. Through computer simulation of this problem, we have calculated attributes and variables sample sizes as a function of falsification, measurement uncertainties, and required detection probability without using approximations. Using realistic assumptions for uncertainty parameters of measurement, the simulation results support the conclusions: (1) previously used conservative approximations can be expensive because they lead to larger sample sizes than needed; and (2) the optimal verification strategy, as well as the falsification strategy, are highly dependent on the underlying uncertainty parameters of the measurement instruments. 1 ref., 3 figs

  11. Development of custom measurement system for biomechanical evaluation of independent wheelchair transfers.

    Science.gov (United States)

    Koontz, Alicia M; Lin, Yen-Sheng; Kankipati, Padmaja; Boninger, Michael L; Cooper, Rory A

    2011-01-01

    This study describes a new custom measurement system designed to investigate the biomechanics of sitting-pivot wheelchair transfers and assesses the reliability of selected biomechanical variables. Variables assessed include horizontal and vertical reaction forces underneath both hands and three-dimensional trunk, shoulder, and elbow range of motion. We examined the reliability of these measures between 5 consecutive transfer trials for 5 subjects with spinal cord injury and 12 nondisabled subjects while they performed a self-selected sitting pivot transfer from a wheelchair to a level bench. A majority of the biomechanical variables demonstrated moderate to excellent reliability (r > 0.6). The transfer measurement system recorded reliable and valid biomechanical data for future studies of sitting-pivot wheelchair transfers.We recommend a minimum of five transfer trials to obtain a reliable measure of transfer technique for future studies.

  12. Measuring the chemical and cytotoxic variability of commercially available kava (Piper methysticum G. Forster.

    Directory of Open Access Journals (Sweden)

    Amanda C Martin

    Full Text Available Formerly used world-wide as a popular botanical medicine to reduce anxiety, reports of hepatotoxicity linked to consuming kava extracts in the late 1990s have resulted in global restrictions on kava use and have hindered kava-related research. Despite its presence on the United States Food and Drug Administration consumer advisory list for the past decade, export data from kava producing countries implies that US kava imports, which are not publicly reported, are both increasing and of a fairly high volume. We have measured the variability in extract chemical composition and cytotoxicity towards human lung adenocarcinoma A549 cancer cells of 25 commercially available kava products. Results reveal a high level of variation in chemical content and cytotoxicity of currently available kava products. As public interest and use of kava products continues to increase in the United States, efforts to characterize products and expedite research of this potentially useful botanical medicine are necessary.

  13. An assessment of variability in radiocarbon dating

    International Nuclear Information System (INIS)

    Scott, E.M.; Baxter, M.S.; Aitchison, T.C.

    1981-01-01

    A series of replicate experiments, involving analysis of homogenized wood and identical tree-ring sections, suggests that the 14 C counting error in radiocarbon dating quantifies only part of the total variability of measurement. Statistical modelling implies that a more realistic assessment of error is provided by a value approximately three times the counting error. The incorporation of this more realistic measure of variability into an appropriate procedure for calibrating a single date and for matching a floating chronology to a master chronology is described. (author)

  14. Annual Research Review: Reaction time variability in ADHD and autism spectrum disorders: measurement and mechanisms of a proposed trans-diagnostic phenotype

    Science.gov (United States)

    Karalunas, Sarah L.; Geurts, Hilde M.; Konrad, Kerstin; Bender, Stephan; Nigg, Joel T.

    2014-01-01

    Background Intraindividual variability in reaction time (RT) has received extensive discussion as an indicator of cognitive performance, a putative intermediate phenotype of many clinical disorders, and a possible trans-diagnostic phenotype that may elucidate shared risk factors for mechanisms of psychiatric illnesses. Scope and Methodology Using the examples of attention deficit hyperactivity disorder (ADHD) and autism spectrum disorders (ASD), we discuss RT variability. We first present a new meta-analysis of RT variability in ASD with and without comorbid ADHD. We then discuss potential mechanisms that may account for RT variability and statistical models that disentangle the cognitive processes affecting RTs. We then report a second meta-analysis comparing ADHD and non-ADHD children on diffusion model parameters. We consider how findings inform the search for neural correlates of RT variability. Findings Results suggest that RT variability is increased in ASD only when children with comorbid ADHD are included in the sample. Furthermore, RT variability in ADHD is explained by moderate to large increases (d = 0.63–0.99) in the ex-Gaussian parameter τ and the diffusion parameter drift rate, as well as by smaller differences (d = 0.32) in the diffusion parameter of nondecision time. The former may suggest problems in state regulation or arousal and difficulty detecting signal from noise, whereas the latter may reflect contributions from deficits in motor organization or output. The neuroimaging literature converges with this multicomponent interpretation and also highlights the role of top-down control circuits. Conclusion We underscore the importance of considering the interactions between top-down control, state regulation (e.g. arousal), and motor preparation when interpreting RT variability and conclude that decomposition of the RT signal provides superior interpretive power and suggests mechanisms convergent with those implicated using other cognitive

  15. Calculus of one variable

    CERN Document Server

    Grossman, Stanley I

    1986-01-01

    Calculus of One Variable, Second Edition presents the essential topics in the study of the techniques and theorems of calculus.The book provides a comprehensive introduction to calculus. It contains examples, exercises, the history and development of calculus, and various applications. Some of the topics discussed in the text include the concept of limits, one-variable theory, the derivatives of all six trigonometric functions, exponential and logarithmic functions, and infinite series.This textbook is intended for use by college students.

  16. Advances in Understanding Decadal Climate Variability

    Science.gov (United States)

    Busalacchi, Antonio J.

    1999-01-01

    Recently, a joint Brazil-France-U.S. program, known as PIRATA (Pilot Research moored Array in the Tropical Atlantic), was proposed to begin the deployment of moored measurement platforms in the tropical Atlantic in order to enhance the existing observational data base and subsequent understanding of the processes by which the ocean and atmosphere couple in key regions of the tropical Atlantic Ocean. Empirical studies have suggested that there are strong relationships between tropical Atlantic upper ocean variability, SST, ocean-atmosphere coupling and regional climate variability. During the early 1980's a coordinated set of surface wind, subsurface thermal structure, and subsurface current observations were obtained as part of the U.S.-France SEQUAL-FOCAL process experiment designed to observe the seasonal response of the tropical Atlantic Ocean to surface forcing. Since that time, however, the observational data base for the tropical Atlantic Ocean has disintegrated to a few ship-tracks measuring ocean temperatures and a small collection of tide gauge stations measuring sea level. A more comprehensive set of observations, modeling and empirical studies is now in order to make progress on understanding the regional climate variability. The proposed PIRATA program will use mooring platforms similar to the tropical Pacific Ocean TAO array to measure surface fluxes of momentum and heat and the corresponding changes in the upper ocean thermal structure. It is anticipated that the oceanic data from this monitoring array will also be used in a predictive mode for initialization studies of regional coupled climate models. Of particular interest are zonal and meridional modes of ocean-atmosphere variability within the tropical Atlantic basin that have significant impacts on the regional climate of the bordering continents.

  17. Variability of ozone depleting substances as an indication of emissions in the Pearl River Delta, China

    Science.gov (United States)

    Chang, Chih-Chung; Lai, Cheng-Hsun; Wang, Chieh-Heng; Liu, Ying; Shao, Min; Zhang, Yuanhang; Wang, Jia-Lin

    The continued production and consumption of five major chlorocarbons, i.e., CFC-11 (CCl 3F), CFC-12 (CCl 2F 2), CFC-113 (CCl 2FCClF 2), CH 3CCl 3, and CCl 4, as allowed by developing nations including China under the Montreal Protocol, were assessed by a method employing concentration variability. Measurements of the five ozone depleting substances (ODS) were measured in downtown Guangzhou and a rural site in the Pearl River Delta (PRD), China by both in situ and flask measurements. In order to post a contrast to PRD with a referencing environment of minimal emissions, in situ measurements were also conducted in Taipei, Taiwan, where a decade long phase-out of CFCs has been implemented. In general, the variability of chlorocarbons in the PRD sites was significantly greater than that of Taipei. While the abundance of the five ODSs in Taipei was relatively uniform with a relative standard deviation (RSD) varying between 3% and 16%, their variability in PRD with the exception of CFC-113 was significantly more pronounced, clearly indicating the significant usage of ODSs. The variability of CFC-113 in both cities, however, was nearly indiscernible from the instrumental precision, suggesting little usage of CFC-113 in China. Methyl chloroform in Guangzhou exhibited a strong link to solvent evaporation as it showed a tight correlation with ambient toluene. Alarmingly, CCl 4 was the most variable of the five major chlorocarbons in Guangzhou, which should arouse a serious concern for public health due to its carcinogenicity.

  18. Neural correlates of gait variability in people with multiple sclerosis with fall history.

    Science.gov (United States)

    Kalron, Alon; Allali, Gilles; Achiron, Anat

    2018-05-28

    Investigate the association between step time variability and related brain structures in accordance with fall status in people with multiple sclerosis (PwMS). The study included 225 PwMS. A whole-brain MRI was performed by a high-resolution 3.0-Telsa MR scanner in addition to volumetric analysis based on 3D T1-weighted images using the FreeSurfer image analysis suite. Step time variability was measured by an electronic walkway. Participants were defined as "fallers" (at least two falls during the previous year) and "non-fallers". One hundred and five PwMS were defined as fallers and had a greater step time variability compared to non-fallers (5.6% (S.D.=3.4) vs. 3.4% (S.D.=1.5); p=0.001). MS fallers exhibited a reduced volume in the left caudate and both cerebellum hemispheres compared to non-fallers. By using a linear regression analysis no association was found between gait variability and related brain structures in the total cohort and non-fallers group. However, the analysis found an association between the left hippocampus and left putamen volumes with step time variability in the faller group; p=0.031, 0.048, respectively, controlling for total cranial volume, walking speed, disability, age and gender. Nevertheless, according to the hierarchical regression model, the contribution of these brain measures to predict gait variability was relatively small compared to walking speed. An association between low left hippocampal, putamen volumes and step time variability was found in PwMS with a history of falls, suggesting brain structural characteristics may be related to falls and increased gait variability in PwMS. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. An AUC-based permutation variable importance measure for random forests.

    Science.gov (United States)

    Janitza, Silke; Strobl, Carolin; Boulesteix, Anne-Laure

    2013-04-05

    The random forest (RF) method is a commonly used tool for classification with high dimensional data as well as for ranking candidate predictors based on the so-called random forest variable importance measures (VIMs). However the classification performance of RF is known to be suboptimal in case of strongly unbalanced data, i.e. data where response class sizes differ considerably. Suggestions were made to obtain better classification performance based either on sampling procedures or on cost sensitivity analyses. However to our knowledge the performance of the VIMs has not yet been examined in the case of unbalanced response classes. In this paper we explore the performance of the permutation VIM for unbalanced data settings and introduce an alternative permutation VIM based on the area under the curve (AUC) that is expected to be more robust towards class imbalance. We investigated the performance of the standard permutation VIM and of our novel AUC-based permutation VIM for different class imbalance levels using simulated data and real data. The results suggest that the new AUC-based permutation VIM outperforms the standard permutation VIM for unbalanced data settings while both permutation VIMs have equal performance for balanced data settings. The standard permutation VIM loses its ability to discriminate between associated predictors and predictors not associated with the response for increasing class imbalance. It is outperformed by our new AUC-based permutation VIM for unbalanced data settings, while the performance of both VIMs is very similar in the case of balanced classes. The new AUC-based VIM is implemented in the R package party for the unbiased RF variant based on conditional inference trees. The codes implementing our study are available from the companion website: http://www.ibe.med.uni-muenchen.de/organisation/mitarbeiter/070_drittmittel/janitza/index.html.

  20. Multiple Measures of Outcome in Assessing a Prison-Based Drug Treatment Program

    Science.gov (United States)

    Prendergast, Michael L.; Hall, Elizabeth A.; Wexler, Harry K.

    2003-01-01

    Evaluations of prison-based drug treatment programs typically focus on one or two dichotomous outcome variables related to recidivism. In contrast, this paper uses multiple measures of outcomes related to crime and drug use to examine the impact of prison treatment. Crime variables included self-report data of time to first illegal activity,…