WorldWideScience

Sample records for measured spc mtf

  1. Measurement of atmospheric MTF in a littoral environment

    CSIR Research Space (South Africa)

    Griffith, DJ

    2008-09-01

    Full Text Available Measurement of atmospheric modulation transfer function (MTF) derived from the point spread function is an alternative to the use of scintillometry in characterizing the effects of turbulence as well as optical scattering. This experiment involved...

  2. MTF measurement of IR optics in different temperature ranges

    Science.gov (United States)

    Bai, Alexander; Duncker, Hannes; Dumitrescu, Eugen

    2017-10-01

    Infrared (IR) optical systems are at the core of many military, civilian and manufacturing applications and perform mission critical functions. To reliably fulfill the demanding requirements imposed on today's high performance IR optics, highly accurate, reproducible and fast lens testing is of crucial importance. Testing the optical performance within different temperature ranges becomes key in many military applications. Due to highly complex IR-Applications in the fields of aerospace, military and automotive industries, MTF Measurement under realistic environmental conditions become more and more relevant. A Modulation Transfer Function (MTF) test bench with an integrated thermal chamber allows measuring several sample sizes in a temperature range from -40 °C to +120°C. To reach reliable measurement results under these difficult conditions, a specially developed temperature stable design including an insulating vacuum are used. The main function of this instrument is the measurement of the MTF both on- and off-axis at up to +/-70° field angle, as well as measurement of effective focal length, flange focal length and distortion. The vertical configuration of the system guarantees a small overall footprint. By integrating a high-resolution IR camera with focal plane array (FPA) in the detection unit, time consuming measurement procedures such as scanning slit with liquid nitrogen cooled detectors can be avoided. The specified absolute accuracy of +/- 3% MTF is validated using internationally traceable reference optics. Together with a complete and intuitive software solution, this makes the instrument a turn-key device for today's state-of- the-art optical testing.

  3. Sinusoidal modulation analysis for optical system MTF measurements.

    Science.gov (United States)

    Boone, J M; Yu, T; Seibert, J A

    1996-12-01

    The modulation transfer function (MTF) is a commonly used metric for defining the spatial resolution characteristics of imaging systems. While the MTF is defined in terms of how an imaging system demodulates the amplitude of a sinusoidal input, this approach has not been in general use to measure MTFs in the medical imaging community because producing sinusoidal x-ray patterns is technically difficult. However, for optical systems such as charge coupled devices (CCD), which are rapidly becoming a part of many medical digital imaging systems, the direct measurement of modulation at discrete spatial frequencies using a sinusoidal test pattern is practical. A commercially available optical test pattern containing spatial frequencies ranging from 0.375 cycles/mm to 80 cycles/mm was sued to determine the MRF of a CCD-based optical system. These results were compared with the angulated slit method of Fujita [H. Fujita, D. Tsia, T. Itoh, K. Doi, J. Morishita, K. Ueda, and A. Ohtsuka, "A simple method for determining the modulation transfer function in digital radiography," IEEE Trans. Medical Imaging 11, 34-39 (1992)]. The use of a semiautomated profiled iterated reconstruction technique (PIRT) is introduced, where the shift factor between successive pixel rows (due to angulation) is optimized iteratively by least-squares error analysis rather than by hand measurement of the slit angle. PIRT was used to find the slit angle for the Fujita technique and to find the sine-pattern angle for the sine-pattern technique. Computer simulation of PIRT for the case of the slit image (a line spread function) demonstrated that it produced a more accurate angle determination than "hand" measurement, and there is a significant difference between the errors in the two techniques (Wilcoxon Signed Rank Test, p < 0.001). The sine-pattern method and the Fujita slit method produced comparable MTF curves for the CCD camera evaluated.

  4. Modulation transfer function (MTF) measurement method based on support vector machine (SVM)

    Science.gov (United States)

    Zhang, Zheng; Chen, Yueting; Feng, Huajun; Xu, Zhihai; Li, Qi

    2016-03-01

    An imaging system's spatial quality can be expressed by the system's modulation spread function (MTF) as a function of spatial frequency in terms of the linear response theory. Methods have been proposed to assess the MTF of an imaging system using point, slit or edge techniques. The edge method is widely used for the low requirement of targets. However, the traditional edge methods are limited by the edge angle. Besides, image noise will impair the measurement accuracy, making the measurement result unstable. In this paper, a novel measurement method based on the support vector machine (SVM) is proposed. Image patches with different edge angles and MTF levels are generated as the training set. Parameters related with MTF and image structure are extracted from the edge images. Trained with image parameters and the corresponding MTF, the SVM classifier can assess the MTF of any edge image. The result shows that the proposed method has an excellent performance on measuring accuracy and stability.

  5. MTF measurement and analysis of linear array HgCdTe infrared detectors

    Science.gov (United States)

    Zhang, Tong; Lin, Chun; Chen, Honglei; Sun, Changhong; Lin, Jiamu; Wang, Xi

    2018-01-01

    The slanted-edge technique is the main method for measurement detectors MTF, however this method is commonly used on planar array detectors. In this paper the authors present a modified slanted-edge method to measure the MTF of linear array HgCdTe detectors. Crosstalk is one of the major factors that degrade the MTF value of such an infrared detector. This paper presents an ion implantation guard-ring structure which was designed to effectively absorb photo-carriers that may laterally defuse between adjacent pixels thereby suppressing crosstalk. Measurement and analysis of the MTF of the linear array detectors with and without a guard-ring were carried out. The experimental results indicated that the ion implantation guard-ring structure effectively suppresses crosstalk and increases MTF value.

  6. Comparison of bar pattern and edge method for MTF measurement in radiology quality control

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, M.; Alves, A.F.F; Bacchim Neto, F.A.; Pavan, A.L.M.; Rosa, M.E.D.; Miranda, J.R.A.; Pina, D.R. de, E-mail: drpina@fmb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil)

    2015-08-15

    Spatial resolution is one of the parameters that is routinely checked during acceptance procedures and regular quality control measurements. The spatial resolution of a radiographic imaging device is most appropriately expressed in terms of its modulation transfer function (MTF), which indicates the decline of detector spatial resolution with spatial frequency. Traditionally used methods of MTF measurement involve imaging either a narrow slit or a sharp edge to obtain the detector line spread function (LSF), whose frequency transform leads to the MTF. In this work is presented a study of the measurement of the limiting spatial resolution using the MTF method and the line-pair bar-pattern method. Our aim is to compare the bar-pattern method with the MTF method and then evaluate what method is the best for the dairy quality control tests and when is better to perform one test or other. These acquisition procedures were tested according to its reproducibility and variation due to noise. (author)

  7. Fabrication of MTF measurement system for a mobile phone lens using multi-square objects

    Science.gov (United States)

    Hong, Sung Mok; Jo, Jae Heung; Lee, Hoi Youn; Yang, Ho Soon; Lee, Yun Woo; Lee, In Won

    2007-12-01

    The mobile phone market grows rapidly and the performance estimation about camera module is required. Accordingly, we fabricate the MTF measurement system for a mobile phone lens having extremely small diameter and large f-number. The objective lens with the magnification of X20 for MTF measurement for high resolution lens and a detector of CCD that is pixel size of 7.4 um are adapted to the system. Also, the CCD is translated by using a linear motor to reduce measurement errors. The measurement lens is placed at the most suitable imaging point by a precise auto-focusing motor. The measuring equipment which we developed for off-axis MTF measurement of a mobile phone lens used the multi-square objects. The square objects of measuring equipment are arranged a unit in the on-axis and total 12 units (0.3 field: 4 units, 0.5 field: 4 units, 0.7 field: 4 units) in the off-axis. When the measurement is started, the linear motors of signal detection part are transferred from on-axis to off-axis. And a detected signals from the each square objects are used for MTF measurement. System driver and MTF measure are using application program that developed us. This software can be measure the on-axis and the off-axis sequentially. In addition to that it did optimization of motor transfer for measurement time shortening.

  8. Methods for reduction of scattered x-ray in measuring MTF with the square chart

    International Nuclear Information System (INIS)

    Hatagawa, Masakatsu; Yoshida, Rie

    1982-01-01

    A square wave chart has been used to measure the MTF of a screen-film system. The problem is that the scattered X-ray from the chart may give rise to measurement errors. In this paper, the authors proposed two methods to reduce the scattered X-ray: the first method is the use of a Pb mask and second is to provide for an air gap between the chart and the screen-film system. In these methods, the scattered X-ray from the chart was reduced. MTFs were measured by both of the new methods and the conventional method, and MTF values of the new methods were in good agreement while that of the conventional method was not. It was concluded that these new methods are able to reduce errors in the measurement of MTF. (author)

  9. The effect of split pixel HDR image sensor technology on MTF measurements

    Science.gov (United States)

    Deegan, Brian M.

    2014-03-01

    Split-pixel HDR sensor technology is particularly advantageous in automotive applications, because the images are captured simultaneously rather than sequentially, thereby reducing motion blur. However, split pixel technology introduces artifacts in MTF measurement. To achieve a HDR image, raw images are captured from both large and small sub-pixels, and combined to make the HDR output. In some cases, a large sub-pixel is used for long exposure captures, and a small sub-pixel for short exposures, to extend the dynamic range. The relative size of the photosensitive area of the pixel (fill factor) plays a very significant role in the output MTF measurement. Given an identical scene, the MTF will be significantly different, depending on whether you use the large or small sub-pixels i.e. a smaller fill factor (e.g. in the short exposure sub-pixel) will result in higher MTF scores, but significantly greater aliasing. Simulations of split-pixel sensors revealed that, when raw images from both sub-pixels are combined, there is a significant difference in rising edge (i.e. black-to-white transition) and falling edge (white-to-black) reproduction. Experimental results showed a difference of ~50% in measured MTF50 between the falling and rising edges of a slanted edge test chart.

  10. Accurate and cost-effective MTF measurement system for lens modules of digital cameras

    Science.gov (United States)

    Chang, Gao-Wei; Liao, Chia-Cheng; Yeh, Zong-Mu

    2007-01-01

    For many years, the widening use of digital imaging products, e.g., digital cameras, has given rise to much attention in the market of consumer electronics. However, it is important to measure and enhance the imaging performance of the digital ones, compared to that of conventional cameras (with photographic films). For example, the effect of diffraction arising from the miniaturization of the optical modules tends to decrease the image resolution. As a figure of merit, modulation transfer function (MTF) has been broadly employed to estimate the image quality. Therefore, the objective of this paper is to design and implement an accurate and cost-effective MTF measurement system for the digital camera. Once the MTF of the sensor array is provided, that of the optical module can be then obtained. In this approach, a spatial light modulator (SLM) is employed to modulate the spatial frequency of light emitted from the light-source. The modulated light going through the camera under test is consecutively detected by the sensors. The corresponding images formed from the camera are acquired by a computer and then, they are processed by an algorithm for computing the MTF. Finally, through the investigation on the measurement accuracy from various methods, such as from bar-target and spread-function methods, it appears that our approach gives quite satisfactory results.

  11. Modified SPC for short run test and measurement process in multi-stations

    Science.gov (United States)

    Koh, C. K.; Chin, J. F.; Kamaruddin, S.

    2018-03-01

    Due to short production runs and measurement error inherent in electronic test and measurement (T&M) processes, continuous quality monitoring through real-time statistical process control (SPC) is challenging. Industry practice allows the installation of guard band using measurement uncertainty to reduce the width of acceptance limit, as an indirect way to compensate the measurement errors. This paper presents a new SPC model combining modified guard band and control charts (\\bar{\\text{Z}} chart and W chart) for short runs in T&M process in multi-stations. The proposed model standardizes the observed value with measurement target (T) and rationed measurement uncertainty (U). S-factor (S f) is introduced to the control limits to improve the sensitivity in detecting small shifts. The model was embedded in automated quality control system and verified with a case study in real industry.

  12. The measurement of the presampled MTF of a high spatial resolution neutron imaging system

    International Nuclear Information System (INIS)

    Cao, Raymond Lei; Biegalski, Steven R.

    2007-01-01

    A high spatial resolution neutron imaging device was developed at the Mark II TRIGA reactor at University of Texas at Austin. As the modulation transfer function (MTF) is recognized as a well-established parameter for evaluation of imaging system resolution, the aliasing associated with digital sampling adds complexity to its measurement. Aliasing is especially problematic when using a high spatial resolution micro-channel plate (MCP) neutron detector that has a pixel grid size similar to that of a CCD array. To compensate for the aliasing an angulated edge method was used to evaluate the neutron imaging facility, overcoming aliasing by obtaining an oversampled edge spread function (ESF). Baseline correction was applied to the ESF to remove the noticeable trends and the LSF was multiplied by Hann window to obtain a smoothed version of presampled MTF. The computing procedure is confirmed by visual inspection of a testing phantom; in addition, it is confirmed by comparison to the MTF measurement of a scintillation screen with a known MTF curve

  13. LCD displays performance comparison by MTF measurement using the white noise stimulus method

    Science.gov (United States)

    Mitjà, Carles; Escofet, Jaume

    2011-01-01

    The amount of images produced to be viewed as soft copies on output displays are significantly increasing. This growing occurs at the expense of the images targeted to hard copy versions on paper or any other physical support. Even in the case of high quality hard copy production, people working in professional imaging uses different displays in selecting, editing, processing and showing images, from laptop screen to specialized high end displays. Then, the quality performance of these devices is crucial in the chain of decisions to be taken in image production. Metrics of this quality performance can help in the equipment acquisition. Different metrics and methods have been described to determine the quality performance of CRT and LCD computer displays in clinical area. One of most important metrics in this field is the device spatial frequency response obtained measuring the modulation transfer function (MTF). This work presents a comparison between the MTF of three different LCD displays, Apple MacBook Pro 15", Apple LED Cinema Display 24" and Apple iPhone4, measured by the white noise stimulus method, over vertical and horizontal directions. Additionally, different displays show particular pixels structure pattern. In order to identify this pixel structure, a set of high magnification images is taken from each display to be related with the respective vertical and horizontal MTF.

  14. On-Orbit MTF Measurement and Product Quality Monitoring for Commercial Remote Sensing Systems

    Science.gov (United States)

    Person, Steven

    2007-01-01

    Initialization and opportunistic targets are chosen that represent the MTF on the spatial domain. Ideal targets have simple mathematical relationships. Determine the MTF of an on-orbit satellite using in-scene targets: Slant-Edge, Line Source, point Source, and Radial Target. Attempt to facilitate the MTF calculation by automatically locating targets of opportunity. Incorporate MTF results into a product quality monitoring architecture.

  15. MTF Database: A Repository of Students' Academic Performance Measurements for the Development of Techniques for Evaluating Team Functioning

    Science.gov (United States)

    Hsiung, Chin-Min; Zheng, Xiang-Xiang

    2015-01-01

    The Measurements for Team Functioning (MTF) database contains a series of student academic performance measurements obtained at a national university in Taiwan. The measurements are acquired from unit tests and homework tests performed during a core mechanical engineering course, and provide an objective means of assessing the functioning of…

  16. Effects of slant angle and illumination angle on MTF estimations

    CSIR Research Space (South Africa)

    Vhengani, LM

    2012-07-01

    Full Text Available Modulation Transfer Function (MTF) is a measure of the spatial resolution of an optical imaging system. For Earth Observation (EO) imaging systems in space, continuous MTF assessment is crucial for data quality. Several techniques of measuring MTF...

  17. Determination of radar MTF

    Energy Technology Data Exchange (ETDEWEB)

    Chambers, D. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    The ultimate goal of the Current Meter Array (CMA) is to be able to compare the current patterns detected with the array with radar images of the water surface. The internal wave current patterns modulate the waves on the water surface giving a detectable modulation of the radar cross-section (RCS). The function relating the RCS modulations to the current patterns is the Modulation Transfer Function (MTF). By comparing radar images directly with co-located CMA measurements the MTF can be determined. In this talk radar images and CMA measurements from a recent experiment at Loch Linnhe, Scotland, will be used to make the first direct determination of MTF for an X and S band radar at low grazing angles. The technical problems associated with comparing radar images to CMA data will be explained and the solution method discussed. The results suggest the both current and strain rate contribute equally to the radar modulation for X band. For S band, the strain rate contributes more than the current. The magnitude of the MTF and the RCS modulations are consistent with previous estimates when the wind is blowing perpendicular to the radar look direction.

  18. Measured and calculated K-fluorescence effects on the MTF of an amorphous-selenium based CCD x-ray detector.

    Science.gov (United States)

    Hunter, David M; Belev, George; Kasap, Safa; Yaffe, Martin J

    2012-02-01

    Theoretical reasoning suggests that direct conversion digital x-ray detectors based upon photoconductive amorphous-selenium (a-Se) could attain very high values of the MTF (modulation transfer function) at spatial frequencies well beyond 20 cycles mm(-1). One of the fundamental factors affecting resolution loss, particularly at x-ray energies just above the K-edge of selenium (12.66 keV), is the K-fluorescence reabsorption mechanism, wherein energy can be deposited in the detector at locations laterally displaced from the initial x-ray interaction site. This paper compares measured MTF changes above and below the Se K-edge of a CCD based a-Se x-ray detector with theoretical expectations. A prototype 25 μm sampling pitch (Nyquist frequency = 20 cycles mm(-1), 200 μm thick a-Se layer based x-ray detector, utilizing a specialized CCD readout device (200 × 400 area array), was used to make edge images with monochromatic x-rays above and below the K-edge of Se. A vacuum double crystal monochromator, exposed to polychromatic x-rays from a synchrotron, formed the monochromatic x-ray source. The monochromaticity of the x-rays was 99% or better. The presampling MTF was determined using the slanted edge method. The theory modeling the MTF performance of the detector includes the basic x-ray interaction physics in the a-Se layer as well as effects related to the operation of the CCD and charge trapping at a blocking layer present at the CCD/a-Se interface. The MTF performance of the prototype a-Se CCD was reduced from the theoretical value prescribed by the basic Se x-ray interaction physics, principally by the presence of a blocking layer. Nevertheless, the K-fluorescence reduction in the MTF was observed, approximately as predicted by theory. For the CCD prototype detector, at five cycles mm(-1), there was a 14% reduction of the MTF, from a value of 0.7 below the K-edge of Se, to 0.6 just above the K-edge. The MTF of an a-Se x-ray detector has been measured using

  19. Main Test Floor (MTF)

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose: The MTF is employed to validate advanced structural concepts and verify new analytical methodologies. Test articles range in size from subcomponent to full...

  20. Unified MTF for scintillator-coupled CMOS sensor

    International Nuclear Information System (INIS)

    Kim, Kwang Hyun; Kang, Dong-Wan; Kim, Dong Ki; Kim, Yong-Kyun

    2007-01-01

    The spatial resolution of scintillator-coupled CMOS sensor has been investigated from intrinsic sensor Modulation Transfer Function (MTF) to system MTF for the conditions of the digital radiography. For the intrinsic sensor MTF, the geometric MTF (gMTF) and the unified MTF (uMTF) were compared by analytic calculations for various pixel sizes. The effects of the initial dark signal of the sensor were considered in the calculation of the uMTF and reflected in a newly developed semi-empirical model. The measured system MTF and the calculated system MTF including semi-empirical model were compared under radiography conditions of 28 and 80 kVp. From the results, the calculated system MTF reflecting the dark-signal contribution on the sensor resolution did fit for the measured system resolution, and the higher the fraction of an initial dark signal to an output signal in response to X-ray exposure showed more degradation of the system resolution even with same scintillator and sensor

  1. Numerical simulation of the modulation transfer function (MTF) in infrared focal plane arrays: simulation methodology and MTF optimization

    Science.gov (United States)

    Schuster, J.

    2018-02-01

    Military requirements demand both single and dual-color infrared (IR) imaging systems with both high resolution and sharp contrast. To quantify the performance of these imaging systems, a key measure of performance, the modulation transfer function (MTF), describes how well an optical system reproduces an objects contrast in the image plane at different spatial frequencies. At the center of an IR imaging system is the focal plane array (FPA). IR FPAs are hybrid structures consisting of a semiconductor detector pixel array, typically fabricated from HgCdTe, InGaAs or III-V superlattice materials, hybridized with heat/pressure to a silicon read-out integrated circuit (ROIC) with indium bumps on each pixel providing the mechanical and electrical connection. Due to the growing sophistication of the pixel arrays in these FPAs, sophisticated modeling techniques are required to predict, understand, and benchmark the pixel array MTF that contributes to the total imaging system MTF. To model the pixel array MTF, computationally exhaustive 2D and 3D numerical simulation approaches are required to correctly account for complex architectures and effects such as lateral diffusion from the pixel corners. It is paramount to accurately model the lateral di_usion (pixel crosstalk) as it can become the dominant mechanism limiting the detector MTF if not properly mitigated. Once the detector MTF has been simulated, it is directly decomposed into its constituent contributions to reveal exactly what is limiting the total detector MTF, providing a path for optimization. An overview of the MTF will be given and the simulation approach will be discussed in detail, along with how different simulation parameters effect the MTF calculation. Finally, MTF optimization strategies (crosstalk mitigation) will be discussed.

  2. Camera System MTF: combining optic with detector

    Science.gov (United States)

    Andersen, Torben B.; Granger, Zachary A.

    2017-08-01

    MTF is one of the most common metrics used to quantify the resolving power of an optical component. Extensive literature is dedicated to describing methods to calculate the Modulation Transfer Function (MTF) for stand-alone optical components such as a camera lens or telescope, and some literature addresses approaches to determine an MTF for combination of an optic with a detector. The formulations pertaining to a combined electro-optical system MTF are mostly based on theory, and assumptions that detector MTF is described only by the pixel pitch which does not account for wavelength dependencies. When working with real hardware, detectors are often characterized by testing MTF at discrete wavelengths. This paper presents a method to simplify the calculation of a polychromatic system MTF when it is permissible to consider the detector MTF to be independent of wavelength.

  3. Crossover And MTF Characteristics Of A Tabular-Grain X-Ray Film

    Science.gov (United States)

    Huff, K. E.; Wagner, P. W.

    1984-08-01

    An orthochromatic x-ray film made with tabular silver halide grains has a significantly higher MTF when exposed with green-emitting intensifying screens than do conventional films with similar sensitometric properties. The primary reason for the improved MTF is a decrease in the amount of crossover exposure, i.e., exposure by light that has crossed the support one or more times. Two well-established sensitometric procedures for measuring crossover have been compared. One produces results accurate enough for calculations of MTF relationships. Calculated MTF relationships for tabulargrain and conventional films are compared with measured values.

  4. Estimation of presampling MTF in CR systems by using direct fluorescence and its problems

    International Nuclear Information System (INIS)

    Ono, Kitahei; Inatsu, Hiroshi; Harao, Mototsugu; Itonaga, Haruo; Miyamoto, Hideyuki

    2001-01-01

    We proposed a method for practical estimation of the presampling modulation transfer function (MTF) of a computed radiography (CR) system by using the MTFs of an imaging plate and the sampling aperture. The MTFs of three imaging plates (GP-25, ST-VN, and RP-1S) with different photostimulable phosphors were measured by using direct fluorescence (the light emitted instantaneously by x-ray exposure), and the presampling MTFs were estimated from these imaging plate MTFs and the sampling aperture MTF. Our results indicated that for imaging plate RP-1S the measured presampling MTF was significantly superior to the estimated presampling MTF at any spatial frequency. This was because the estimated presampling MTF was degraded by the diffusion of direct fluorescence in the protective layer of the imaging plate's surface. Therefore, when the presampling MTF of the imaging plate with a thick protective layer is estimated, correction for the thickness of the protective layer should be carried out. However, the estimated presampling MTF of imaging plates with a thin protective layer were almost the same as the measured presampling MTF, except in the high spatial frequency range. Therefore, we consider this estimation method to be useful and practical, because the spatial resolution property of a CR system can be obtained simply from the imaging plate MTF measured with direct fluorescence. (author)

  5. Computation of the MTF with a microdensitometer and a computer on-line system

    International Nuclear Information System (INIS)

    Sukenobu, Yoshiharu; Sasagaki, Michihiro; Asada, Tomohiro; Yamaguchi, Kazuya; Takigawa, Atsushi

    1984-01-01

    One of the most popular evaluation methods of radiographic images is the measurement of modulation transfer function (MTF) using the slit method, which is very useful to compare similar characters of film-screen systems. However, it is difficult ot measure the MTF plainly without a loss in accuracy. So, we connected a microdensitometer to the computer and wrote a computer program which was able to measure the MTF automatically. To reduce the fluctuations and uncertainties in the calculated MTF, we examined the process from the film scanning by microdensitometer to the MTF calculating by Fourier transformation. We firmly believe that the linearization process is the most important process to reduce MTF fluctuations. As a result of using the SPLINE function (H D curve approximate expression) in the process of linearization decreases fluctuations and uncertainties of the MTF were able to be when it was included in the manual measurement. We were able to save a great deal of work when we measured the MTF. (author)

  6. Study on the DNA-protein crosslinks induced by chromium (VI) in SPC-A1

    Science.gov (United States)

    Liu, Yanqun; Ding, Jianjun; Lu, Xiongbing; You, Hao

    2018-01-01

    Objective: This study was designed to investigate the effect of chromium (VI) on DNA-protein crosslinks (DPC) of SPC-A1 cells. Methods: We exposed SPC-A1 cells were cultured in 1640 medium and treated with the SPC-A1 cells in vitro to different concentrations of Hexavalent chromium Cr(VI) for 2h, the KC1-SDS precipitation assay were used to measure the DNA-protein cross-linking effect. Results: All the different concentrations of Cr(VI) could cause the increase of DPC coefficient in SPC-A1 cells. But this effect was not significant (P>0.05) at low concentrations; while in high concentration Cr(VI) induced SPC-A1 cells could produce DNA-protein cross-linking effect significantly (P<0.05). Conclusions: chromium (VI) could induce DNA-protein crosslink.

  7. Results of subscale MTF compression experiments

    Science.gov (United States)

    Howard, Stephen; Mossman, A.; Donaldson, M.; Fusion Team, General

    2016-10-01

    In magnetized target fusion (MTF) a magnetized plasma torus is compressed in a time shorter than its own energy confinement time, thereby heating to fusion conditions. Understanding plasma behavior and scaling laws is needed to advance toward a reactor-scale demonstration. General Fusion is conducting a sequence of subscale experiments of compact toroid (CT) plasmas being compressed by chemically driven implosion of an aluminum liner, providing data on several key questions. CT plasmas are formed by a coaxial Marshall gun, with magnetic fields supported by internal plasma currents and eddy currents in the wall. Configurations that have been compressed so far include decaying and sustained spheromaks and an ST that is formed into a pre-existing toroidal field. Diagnostics measure B, ne, visible and x-ray emission, Ti and Te. Before compression the CT has an energy of 10kJ magnetic, 1 kJ thermal, with Te of 100 - 200 eV, ne 5x1020 m-3. Plasma was stable during a compression factor R0/R >3 on best shots. A reactor scale demonstration would require 10x higher initial B and ne but similar Te. Liner improvements have minimized ripple, tearing and ejection of micro-debris. Plasma facing surfaces have included plasma-sprayed tungsten, bare Cu and Al, and gettering with Ti and Li.

  8. The statistical process control methods - SPC

    Directory of Open Access Journals (Sweden)

    Floreková Ľubica

    1998-03-01

    Full Text Available Methods of statistical evaluation of quality – SPC (item 20 of the documentation system of quality control of ISO norm, series 900 of various processes, products and services belong amongst basic qualitative methods that enable us to analyse and compare data pertaining to various quantitative parameters. Also they enable, based on the latter, to propose suitable interventions with the aim of improving these processes, products and services. Theoretical basis and applicatibily of the principles of the: - diagnostics of a cause and effects, - Paret analysis and Lorentz curve, - number distribution and frequency curves of random variable distribution, - Shewhart regulation charts, are presented in the contribution.

  9. Making SPC easier with zone control charts

    International Nuclear Information System (INIS)

    Lanning, B.

    1995-01-01

    The zone control chart is a simple, easy to learn statistical process control (SPC) tool that can be applied to any process where the data are normally distributed. Several Shewhart runs rules are incorporated into a simple scoring system, with a single rule to determine when a process is out of control. Zone charts have average run lengths (ARLs) for detecting shifts in the process mean which, for most cases, are uniformly better than the standard control charts. This paper presents the simplified methodology behind the zone control chart

  10. Variation in SPC/STC Ratio as an Indicator of Age: A Computer-aided Forensic Odontology

    Directory of Open Access Journals (Sweden)

    Priyanka Debta

    2010-01-01

    Results: Pearson correlation between SPC/STC ratio with different age group was found to be statistically significant. So, measurement of amount of secondary dentin seems to be reliable and rapid method in forensic odontology.

  11. MTF analysis of the near-real time neutron radiography facility at MURR

    International Nuclear Information System (INIS)

    Lindsay, J.T.; Alger, D.M.; Bull, S.R.; Miller, W.H.

    1983-01-01

    Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.)

  12. X-ray quality assessment by MTF analysis

    International Nuclear Information System (INIS)

    Gais, P.; Burger, G.; Drexler, G.; Rappl, M.; Bunde, E.; Lissner, J.; Schaetzl, M.

    1985-01-01

    In a previous study a lucite phantom with several physical elements embedded, such as lead gratings with varying line widths, etc., was exposed at 200 X-ray installations in Bavaria, Federal Republic of Germany, by a conventional diagnostic standard technique. One of the parameters investigated was the local resolution achieved, determined visually by examination of the grating images. The same radiographs have now been used in a retrospective comparative study, based upon a quantitative analysis of TV images of the films. The films were positioned on a commercial illuminator screen and looked at by a TV camera through a simple magnifying optical system. The video signals were digitised, resulting in a pixel distance of 50 μm. In a first approach the edges of the broad frames of the lead gratings were adjusted vertically and the normalised sum of all 256 TV scanning lines taken as the edge function f(x). This was differentiated and suitably Fourier-transformed, delivering the modulation transfer function (MTF). The MTF can be analysed in several ways to describe quantitatively the maximum local resolution achievable. Correlation of some frequency measurements with the visually determined line resolution is generally good. (author)

  13. Reap what you sow! - But what about SPC squatting?

    DEFF Research Database (Denmark)

    Schovsbo, Jens Hemmingsen; Klinge, Ulla Callesen; Minssen, Timo

    2018-01-01

    Regulations, as well as the practical and theoretical significance of this issue, the lack of judicial guidance is problematic. It is important to address such situations for the sake of legal certainty and in order to enable companies to make strategic decisions. SPC squatting also involves a crucial debate...... about the rationales underlying the SPC system and the question whether such activities are compatible with the very goals of the Regulations. This paper provides an overview on the legal status quo with regard to SPC squatting and discusses if - and if so, under what circumstances - such practices...

  14. Magnetic compression/magnetized target fusion (MAGO/MTF)

    International Nuclear Information System (INIS)

    Kirkpatrick, R.C.; Lindemuth, I.R.

    1997-03-01

    Magnetized Target Fusion (MTF) was reported in two papers at the First Symposium on Current Trends in International Fusion Research. MTF is intermediate between two very different mainline approaches to fusion: Inertial Confinement Fusion (ICF) and magnetic confinement fusion (MCF). The only US MTF experiments in which a target plasma was compressed were the Sandia National Laboratory ''Phi targets''. Despite the very interesting results from that series of experiments, the research was not pursued, and other embodiments of MTF concept such as the Fast Liner were unable to attract the financial support needed for a firm proof of principle. A mapping of the parameter space for MTF showed the significant features of this approach. The All-Russian Scientific Research Institute of Experimental Physics (VNIIEF) has an on-going interest in this approach to thermonuclear fusion, and Los Alamos National Laboratory (LANL) and VNIIEF have done joint target plasma generation experiments relevant to MTF referred to as MAGO (transliteration of the Russian acronym for magnetic compression). The MAGO II experiment appears to have achieved on the order of 200 eV and over 100 KG, so that adiabatic compression with a relatively small convergence could bring the plasma to fusion temperatures. In addition, there are other experiments being pursued for target plasma generation and proof of principle. This paper summarizes the previous reports on MTF and MAGO and presents the progress that has been made over the past three years in creating a target plasma that is suitable for compression to provide a scientific proof of principle experiment for MAGO/MTF

  15. Effective application of statistical process control (SPC) on the lengthwise tonsure rolled plates process

    OpenAIRE

    Noskievičová, Darja; Kucharczyk, Radim

    2012-01-01

    This paper deals with the eff ective application of SPC on the lengthwise tonsure rolled plates process on double side scissors. After explanation of the SPC fundamentals, goals and mistakes during the SPC implementation, the methodical framework for the eff ective SPC application is defi ned. In the next part of the paper the description of practical application of SPC and its analysis from the point of view of this framework is accomplished. Ovaj članak opisuje djelotvornu primj...

  16. Biological indicators for monitoring water quality of MTF canals system

    Science.gov (United States)

    Sethi, S. L.

    1975-01-01

    Biological models, diversity indexes, were developed to predict environmental effects of NASA's Mississippi test facility (MTF) chemical operations on canal systems in the area. To predict the effects on local streams, a physical model of unpolluted streams was established. The model is fed by artesian well water free of background levels of pollutants. The species diversity and biota composition of unpolluted MTF stream was determined; resulting information will be used to form baseline data for future comparisons. Biological modeling was accomplished by adding controlled quantities or kinds of chemical pollutants and evaluating the effects of these chemicals on the biological life of the stream.

  17. Analyzing a Mature Software Inspection Process Using Statistical Process Control (SPC)

    Science.gov (United States)

    Barnard, Julie; Carleton, Anita; Stamper, Darrell E. (Technical Monitor)

    1999-01-01

    This paper presents a cooperative effort where the Software Engineering Institute and the Space Shuttle Onboard Software Project could experiment applying Statistical Process Control (SPC) analysis to inspection activities. The topics include: 1) SPC Collaboration Overview; 2) SPC Collaboration Approach and Results; and 3) Lessons Learned.

  18. Model-based PSF and MTF estimation and validation from skeletal clinical CT images.

    Science.gov (United States)

    Pakdel, Amirreza; Mainprize, James G; Robert, Normand; Fialkov, Jeffery; Whyne, Cari M

    2014-01-01

    A method was developed to correct for systematic errors in estimating the thickness of thin bones due to image blurring in CT images using bone interfaces to estimate the point-spread-function (PSF). This study validates the accuracy of the PSFs estimated using said method from various clinical CT images featuring cortical bones. Gaussian PSFs, characterized by a different extent in the z (scan) direction than in the x and y directions were obtained using our method from 11 clinical CT scans of a cadaveric craniofacial skeleton. These PSFs were estimated for multiple combinations of scanning parameters and reconstruction methods. The actual PSF for each scan setting was measured using the slanted-slit technique within the image slice plane and the longitudinal axis. The Gaussian PSF and the corresponding modulation transfer function (MTF) are compared against the actual PSF and MTF for validation. The differences (errors) between the actual and estimated full-width half-max (FWHM) of the PSFs were 0.09 ± 0.05 and 0.14 ± 0.11 mm for the xy and z axes, respectively. The overall errors in the predicted frequencies measured at 75%, 50%, 25%, 10%, and 5% MTF levels were 0.06 ± 0.07 and 0.06 ± 0.04 cycles/mm for the xy and z axes, respectively. The accuracy of the estimates was dependent on whether they were reconstructed with a standard kernel (Toshiba's FC68, mean error of 0.06 ± 0.05 mm, MTF mean error 0.02 ± 0.02 cycles/mm) or a high resolution bone kernel (Toshiba's FC81, PSF FWHM error 0.12 ± 0.03 mm, MTF mean error 0.09 ± 0.08 cycles/mm). The method is accurate in 3D for an image reconstructed using a standard reconstruction kernel, which conforms to the Gaussian PSF assumption but less accurate when using a high resolution bone kernel. The method is a practical and self-contained means of estimating the PSF in clinical CT images featuring cortical bones, without the need phantoms or any prior knowledge about the scanner-specific parameters.

  19. Model-based PSF and MTF estimation and validation from skeletal clinical CT images

    International Nuclear Information System (INIS)

    Pakdel, Amirreza; Mainprize, James G.; Robert, Normand; Fialkov, Jeffery; Whyne, Cari M.

    2014-01-01

    Purpose: A method was developed to correct for systematic errors in estimating the thickness of thin bones due to image blurring in CT images using bone interfaces to estimate the point-spread-function (PSF). This study validates the accuracy of the PSFs estimated using said method from various clinical CT images featuring cortical bones. Methods: Gaussian PSFs, characterized by a different extent in the z (scan) direction than in the x and y directions were obtained using our method from 11 clinical CT scans of a cadaveric craniofacial skeleton. These PSFs were estimated for multiple combinations of scanning parameters and reconstruction methods. The actual PSF for each scan setting was measured using the slanted-slit technique within the image slice plane and the longitudinal axis. The Gaussian PSF and the corresponding modulation transfer function (MTF) are compared against the actual PSF and MTF for validation. Results: The differences (errors) between the actual and estimated full-width half-max (FWHM) of the PSFs were 0.09 ± 0.05 and 0.14 ± 0.11 mm for the xy and z axes, respectively. The overall errors in the predicted frequencies measured at 75%, 50%, 25%, 10%, and 5% MTF levels were 0.06 ± 0.07 and 0.06 ± 0.04 cycles/mm for the xy and z axes, respectively. The accuracy of the estimates was dependent on whether they were reconstructed with a standard kernel (Toshiba's FC68, mean error of 0.06 ± 0.05 mm, MTF mean error 0.02 ± 0.02 cycles/mm) or a high resolution bone kernel (Toshiba's FC81, PSF FWHM error 0.12 ± 0.03 mm, MTF mean error 0.09 ± 0.08 cycles/mm). Conclusions: The method is accurate in 3D for an image reconstructed using a standard reconstruction kernel, which conforms to the Gaussian PSF assumption but less accurate when using a high resolution bone kernel. The method is a practical and self-contained means of estimating the PSF in clinical CT images featuring cortical bones, without the need phantoms or any prior knowledge about the

  20. Model-based PSF and MTF estimation and validation from skeletal clinical CT images

    Energy Technology Data Exchange (ETDEWEB)

    Pakdel, Amirreza [Sunnybrook Research Institute, Toronto, Ontario M4N 3M5, Canada and Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5S 3M2 (Canada); Mainprize, James G.; Robert, Normand [Sunnybrook Research Institute, Toronto, Ontario M4N 3M5 (Canada); Fialkov, Jeffery [Division of Plastic Surgery, Sunnybrook Health Sciences Center, Toronto, Ontario M4N 3M5, Canada and Department of Surgery, University of Toronto, Toronto, Ontario M5S 3M2 (Canada); Whyne, Cari M., E-mail: cari.whyne@sunnybrook.ca [Sunnybrook Research Institute, Toronto, Ontario M4N 3M5, Canada and Department of Surgery, Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5S 3M2 (Canada)

    2014-01-15

    Purpose: A method was developed to correct for systematic errors in estimating the thickness of thin bones due to image blurring in CT images using bone interfaces to estimate the point-spread-function (PSF). This study validates the accuracy of the PSFs estimated using said method from various clinical CT images featuring cortical bones. Methods: Gaussian PSFs, characterized by a different extent in the z (scan) direction than in the x and y directions were obtained using our method from 11 clinical CT scans of a cadaveric craniofacial skeleton. These PSFs were estimated for multiple combinations of scanning parameters and reconstruction methods. The actual PSF for each scan setting was measured using the slanted-slit technique within the image slice plane and the longitudinal axis. The Gaussian PSF and the corresponding modulation transfer function (MTF) are compared against the actual PSF and MTF for validation. Results: The differences (errors) between the actual and estimated full-width half-max (FWHM) of the PSFs were 0.09 ± 0.05 and 0.14 ± 0.11 mm for the xy and z axes, respectively. The overall errors in the predicted frequencies measured at 75%, 50%, 25%, 10%, and 5% MTF levels were 0.06 ± 0.07 and 0.06 ± 0.04 cycles/mm for the xy and z axes, respectively. The accuracy of the estimates was dependent on whether they were reconstructed with a standard kernel (Toshiba's FC68, mean error of 0.06 ± 0.05 mm, MTF mean error 0.02 ± 0.02 cycles/mm) or a high resolution bone kernel (Toshiba's FC81, PSF FWHM error 0.12 ± 0.03 mm, MTF mean error 0.09 ± 0.08 cycles/mm). Conclusions: The method is accurate in 3D for an image reconstructed using a standard reconstruction kernel, which conforms to the Gaussian PSF assumption but less accurate when using a high resolution bone kernel. The method is a practical and self-contained means of estimating the PSF in clinical CT images featuring cortical bones, without the need phantoms or any prior knowledge

  1. The Implication of the EBC Scorecard on the Skills, Roles, and Tools of Navy MTF Comptrollers

    National Research Council Canada - National Science Library

    Lucas, Jeannette

    1998-01-01

    .... The purpose of this thesis is to present a baseline assessment, describing new skills, roles and tools which comptrollers of Navy MTF are adopting to improve their MTF's performance under the indices of the EBC Scorecard.

  2. [Statistical Process Control (SPC) can help prevent treatment errors without increasing costs in radiotherapy].

    Science.gov (United States)

    Govindarajan, R; Llueguera, E; Melero, A; Molero, J; Soler, N; Rueda, C; Paradinas, C

    2010-01-01

    Statistical Process Control (SPC) was applied to monitor patient set-up in radiotherapy and, when the measured set-up error values indicated a loss of process stability, its root cause was identified and eliminated to prevent set-up errors. Set up errors were measured for medial-lateral (ml), cranial-caudal (cc) and anterior-posterior (ap) dimensions and then the upper control limits were calculated. Once the control limits were known and the range variability was acceptable, treatment set-up errors were monitored using sub-groups of 3 patients, three times each shift. These values were plotted on a control chart in real time. Control limit values showed that the existing variation was acceptable. Set-up errors, measured and plotted on a X chart, helped monitor the set-up process stability and, if and when the stability was lost, treatment was interrupted, the particular cause responsible for the non-random pattern was identified and corrective action was taken before proceeding with the treatment. SPC protocol focuses on controlling the variability due to assignable cause instead of focusing on patient-to-patient variability which normally does not exist. Compared to weekly sampling of set-up error in each and every patient, which may only ensure that just those sampled sessions were set-up correctly, the SPC method enables set-up error prevention in all treatment sessions for all patients and, at the same time, reduces the control costs. Copyright © 2009 SECA. Published by Elsevier Espana. All rights reserved.

  3. A Critical Assessment on SPC Implementation in the UK Food Industry

    Directory of Open Access Journals (Sweden)

    Sarina Abdul Halim Lim

    2016-02-01

    Full Text Available Statistical process control (SPC is one of the most widely applied techniques to control and improve processes in manufacturing industry, but very few studies have reported on the successful application of SPC in the food industry. This paper aims to critically assess the status of SPC in the UK food manufacturing industry and suggests avenues for future research. By surveying the UK food-manufacturing companies, forty-five percent of them were identified implemented SPC, with x-R and x-S charts found to be the most commonly applied SPC charts in this industry. Top management commitment was identified as the most critical factor, while lack of SPC training is the most significant challenge and lack of awareness of SPC as the main reason for food manufacturing companies not implementing SPC. The paper provides information to food companies in the UK on most common practiced and useful quality tools, SPC charts and critical success factors in the food industry. Furthermore, based on the process performance parameters, SPC companies were observed to achieving better results compared to non-SPC companies.

  4. Spatial resolution limit study of a CCD camera and scintillator based neutron imaging system according to MTF determination and analysis

    International Nuclear Information System (INIS)

    Kharfi, F.; Denden, O.; Bourenane, A.; Bitam, T.; Ali, A.

    2012-01-01

    Spatial resolution limit is a very important parameter of an imaging system that should be taken into consideration before examination of any object. The objectives of this work are the determination of a neutron imaging system's response in terms of spatial resolution. The proposed procedure is based on establishment of the Modulation Transfer Function (MTF). The imaging system being studied is based on a high sensitivity CCD neutron camera (2×10 −5 lx at f1.4). The neutron beam used is from the horizontal beam port (H.6) of the Algerian Es-Salam research reactor. Our contribution is on the MTF determination by proposing an accurate edge identification method and a line spread function undersampling problem-resolving procedure. These methods and procedure are integrated into a MatLab code. The methods, procedures and approaches proposed in this work are available for any other neutron imaging system and allow for judging the ability of a neutron imaging system to produce spatial (internal details) properties of any object under examination. - Highlights: ► Determination of spatial response of a neutron imaging system. ► Ability of a neutron imaging system to reproduce spatial properties of any object. ► Spatial resolution limits measurement using MTF with the slanted edge method. ► Accurate edge identification and line spread function sampling improvement. ► Development of a MatLab code to compute automatically the MTF.

  5. Dynamic MTF, an innovative test bench for detector characterization

    Science.gov (United States)

    Emmanuel, Rossi; Raphaël, Lardière; Delmonte, Stephane

    2017-11-01

    PLEIADES HR are High Resolution satellites for Earth observation. Placed at 695km they reach a 0.7m spatial resolution. To allow such performances, the detectors are working in a TDI mode (Time and Delay Integration) which consists in a continuous charge transfer from one line to the consecutive one while the image is passing on the detector. The spatial resolution, one of the most important parameter to test, is characterized by the MTF (Modulation Transfer Function). Usually, detectors are tested in a staring mode. For a higher level of performances assessment, a dedicated bench has been set-up, allowing detectors' MTF characterization in the TDI mode. Accuracy and reproducibility are impressive, opening the door to new perspectives in term of HR imaging systems testing.

  6. MTF Analysis of LANDSAT-4 Thematic Mapper

    Science.gov (United States)

    Schowengerdt, R.

    1985-01-01

    The spatial radiance distribution of a ground target must be known to a resolution at least four to five times greater than that of the system under test when measuring a satellite sensor's modulation transfer function. Calibration of the target requires either the use of man-made special purpose targets with known properties, e.g., a small reflective mirror or a dark-light linear pattern such as line or edge, or use of relatively high resolution underflight imagery to calibrate an arbitrary ground scene. Both approaches are to be used, in addition a technique that utilizes an analytical model of the scene spatial frequency power spectrum is being investigated as an alternative to calibration of the scene.

  7. MO-F-CAMPUS-J-04: One-Year Analysis of Elekta CBCT Image Quality Using NPS and MTF

    International Nuclear Information System (INIS)

    Nakahara, S; Tachibana, M; Watanabe, Y

    2015-01-01

    Purpose: To compare quantitative image quality (IQ) evaluation methods using Noise Power Spectrum (NPS) and Modulation Transfer Function (MTF) with standard IQ analyses for minimizing the observer subjectivity of the standard methods and maximizing the information content. Methods: For our routine IQ tests of Elekta XVI Cone-Beam CT, image noise was quantified by the standard deviation of CT number (CT#) (Sigma) over a small area in an IQ test phantom (CatPhan), and the high spatial resolution (HSR) was evaluated by the number of line-pairs (LP#) visually recognizable on the image. We also measured the image uniformity, the low contrast resolution ratio, and the distances of two points for geometrical accuracy. For this study, we did additional evaluation of the XVI data for 12 monthly IQ tests by using NPS for noise, MTF for HSR, and the CT#-to-density relationship. NPS was obtained by applying Fourier analysis in a small area on the uniformity test section of CatPhan. The MTF analysis was performed by applying the Droege-Morin (D-M) method to the line pairs on the phantom. The CT#-to-density was obtained for inserts in the low-contrast test section of the phantom. Results: All the quantities showed a noticeable change over the one-year period. Especially the noise level changed significantly after a repair of the imager. NPS was more sensitive to the IQ change than Sigma. MTF could provide more quantitative and objective evaluation of the HSR. The CT# was very different from the expected CT#; but, the CT#-to-density curves were constant within 5% except two months. Conclusion: Since the D-M method is easy to implement, we recommend using MTF instead of the LP# even for routine periodic QA. The month-to-month variation of IQ was not negligible; hence a routine IQ test must be performed, particularly after any modification of hardware including detector calibration

  8. MO-F-CAMPUS-J-04: One-Year Analysis of Elekta CBCT Image Quality Using NPS and MTF

    Energy Technology Data Exchange (ETDEWEB)

    Nakahara, S; Tachibana, M [Hiroshima International University, Hiroshma, Hiroshima (Japan); Watanabe, Y [University of Minnesota, Minneapolis, MN (United States)

    2015-06-15

    Purpose: To compare quantitative image quality (IQ) evaluation methods using Noise Power Spectrum (NPS) and Modulation Transfer Function (MTF) with standard IQ analyses for minimizing the observer subjectivity of the standard methods and maximizing the information content. Methods: For our routine IQ tests of Elekta XVI Cone-Beam CT, image noise was quantified by the standard deviation of CT number (CT#) (Sigma) over a small area in an IQ test phantom (CatPhan), and the high spatial resolution (HSR) was evaluated by the number of line-pairs (LP#) visually recognizable on the image. We also measured the image uniformity, the low contrast resolution ratio, and the distances of two points for geometrical accuracy. For this study, we did additional evaluation of the XVI data for 12 monthly IQ tests by using NPS for noise, MTF for HSR, and the CT#-to-density relationship. NPS was obtained by applying Fourier analysis in a small area on the uniformity test section of CatPhan. The MTF analysis was performed by applying the Droege-Morin (D-M) method to the line pairs on the phantom. The CT#-to-density was obtained for inserts in the low-contrast test section of the phantom. Results: All the quantities showed a noticeable change over the one-year period. Especially the noise level changed significantly after a repair of the imager. NPS was more sensitive to the IQ change than Sigma. MTF could provide more quantitative and objective evaluation of the HSR. The CT# was very different from the expected CT#; but, the CT#-to-density curves were constant within 5% except two months. Conclusion: Since the D-M method is easy to implement, we recommend using MTF instead of the LP# even for routine periodic QA. The month-to-month variation of IQ was not negligible; hence a routine IQ test must be performed, particularly after any modification of hardware including detector calibration.

  9. Sun position calculator (SPC) for Landsat imagery with geodetic latitudes

    Science.gov (United States)

    Seong, Jeong C.

    2015-12-01

    Landsat imagery comes with sun position information such as azimuth and sun elevation, but they are available only at the center of a scene. To aid in the use of Landsat imagery for various solar radiation applications such as topographic correction, solar power, urban heat island, agriculture, climate and vegetation, it is necessary to calculate the sun position information at every pixel. This research developed a PC application that creates sun position data layers in ArcGIS at every pixel in a Landsat scene. The SPC program is composed of two major routines - converting universal transverse Mercator (UTM) projection coordinates to geographic longitudes and latitudes, and calculating sun position information based on the Meeus' routine. For the latter, an innovative method was also implemented to account for the Earth's flattening on an ellipsoid. The Meeus routine implemented in this research showed about 0.2‧ of mean absolute difference from the National Renewable Energy Laboratory (NREL) Solar Position Algorithm (SPA) routine when solar zenith and azimuth angles were tested with every 30 min data at four city locations (Fairbanks, Atlanta, Sydney and Rio Grande) on June 30, 2014. The Meeus routine was about ten times faster than the SPA routine. Professionals who need the Sun's position information for Landsat imagery will benefit from the SPC application.

  10. Experimental observation of the improvement in MTF from backthinning a CMOS direct electron detector

    International Nuclear Information System (INIS)

    McMullan, G.; Faruqi, A.R.; Henderson, R.; Guerrini, N.; Turchetta, R.; Jacobs, A.; Hoften, G. van

    2009-01-01

    The advantages of backthinning monolithic active pixel sensors (MAPS) based on complementary metal oxide semiconductor (CMOS) direct electron detectors for electron microscopy have been discussed previously; they include better spatial resolution (modulation transfer function or MTF) and efficiency at all spatial frequencies (detective quantum efficiency or DQE). It was suggested that a 'thin' CMOS detector would have the most outstanding properties because of a reduction in the proportion of backscattered electrons. In this paper we show, theoretically (using Monte Carlo simulations of electron trajectories) and experimentally that this is indeed the case. The modulation transfer functions of prototype backthinned CMOS direct electron detectors have been measured at 300 keV. At zero spatial frequency, in non-backthinned 700-μm-thick detectors, the backscattered component makes up over 40% of the total signal but, by backthinning to 100, 50 or 35 μm, this can be reduced to 25%, 15% and 10%, respectively. For the 35 μm backthinned detector, this reduction in backscatter increases the MTF by 40% for spatial frequencies between 0.1 and 1.0 Nyquist. As discussed in the main text, reducing backscattering in backthinned detectors should also improve DQE.

  11. MTF analysis of the MURR real-time neutron radiography facility

    International Nuclear Information System (INIS)

    Lindsay, J.T.

    1982-01-01

    In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used was to image a knife-edge, differentiate the edge gradient to obtain the line spread function (LSF) to obtain the system MTF. A Gd foil was used for the knife-edge on several neutron converter screens and was imaged by a low-light level ISIT camera. The video signal was then digitized and presented to a PDP-11/05 microcomputer for the numerical calculations

  12. FRC plasma studies on the FRX-L plasma injector for MTF

    International Nuclear Information System (INIS)

    Wurden, G.A.; Intrator, T.P.; Zhang, S.Y.; Furno, I.G.; Hsu, S.C.; Park, J.Y.; Kirkpatrick, R.; Renneke, R.M.; Schoenberg, K.F.; Taccetti, M.J.; Tuszewski, M.G.; Waganaar, W.J.; Zhehui Wang; Siemon, R.E.; Degnan, J.H.; Gale, D.G.; Grabowski, C.; Ruden, E.L.; Sommars, W.; Frese, M.H.; Coffey, S.; Craddock, G.; Frese, S.D.; Roderick, N.F.

    2005-01-01

    To demonstrate the physics basis for Magnetized Target Fusion (MTF), we have designed a field reversed configuration (FRC) target plasma to ultimately be compressed within an imploding metal flux conserver (liner). This new, high energy density FRC device, named FRX-L, is operating at Los Alamos as a compact 'theta-pinch' formation FRC. The system capability includes a 0.5 T bias field, 70 kV 250 kHz ringing pre-ionization, and a 1.5 MA, 200 kJ main-theta-coil bank. We show FRC data with plasma parameters approaching the desired MTF requirements, examples of substantial Ohmic heating from magnetic flux annihilation, and measurements of plasma anomalous resistivity. Improvements are underway to reduce the main bank crowbar ringing, which will increase the trapped flux in the FRC. A prototype deformable flux-conserving liner with large entrance holes to accept an FRC has also been designed with MACH2 (2-D MHD modelling code) and successfully imploded at Kirtland Air Force Base on the Shiva Star pulsed power facility. (author)

  13. Production and characterisation of recombinant forms of human pulmonary surfactant protein C (SP-C)

    DEFF Research Database (Denmark)

    Lukovic, Dunja; Plasencia, Inés; Taberner, Francisco J

    2006-01-01

    Surfactant protein C (SP-C) is an essential component for the surface tension-lowering activity of the pulmonary surfactant system. It contains a valine-rich alpha helix that spans the lipid bilayer, and is one of the most hydrophobic proteins known so far. SP-C is also an essential component of ...

  14. Automation in Siemens fuel manufacturing - the basis for quality improvement by statistical process control (SPC)

    International Nuclear Information System (INIS)

    Drecker, St.; Hoff, A.; Dietrich, M.; Guldner, R.

    1999-01-01

    Statistical Process Control (SPC) is one of the systematic tools to perform a valuable contribution to the control and planning activities for manufacturing processes and product quality. Advanced Nuclear Fuels GmbH (ANF) started a program to introduce SPC in all sections of the manufacturing process of fuel assemblies. The concept phase is based on a realization of SPC in 3 pilot projects. The existing manufacturing devices are reviewed for the utilization of SPC. Subsequent modifications were made to provide the necessary interfaces. The processes 'powder/pellet manufacturing'. 'cladding tube manufacturing' and 'laser-welding of spacers' are located at the different locations of ANF. Due to the completion of the first steps and the experience obtained by the pilot projects, the introduction program for SPC has already been extended to other manufacturing processes. (authors)

  15. Magnetized Target Fusion Propulsion: Plasma Injectors for MTF Guns

    Science.gov (United States)

    Griffin, Steven T.

    2003-01-01

    To achieve increased payload size and decreased trip time for interplanetary travel, a low mass, high specific impulse, high thrust propulsion system is required. This suggests the need for research into fusion as a source of power and high temperature plasma. The plasma would be deflected by magnetic fields to provide thrust. Magnetized Target Fusion (MTF) research consists of several related investigations into these topics. These include the orientation and timing of the plasma guns and the convergence and interface development of the "pusher" plasma. Computer simulations of the gun as it relates to plasma initiation and repeatability are under investigation. One of the items under development is the plasma injector. This is a surface breakdown driven plasma generator designed to function at very low pressures. The performance, operating conditions and limitations of these injectors need to be determined.

  16. Specificity of SPC Procedures Application in Foundry in Aspect of Data Acquisition and Data Exploration

    Directory of Open Access Journals (Sweden)

    Ignaszak Z.

    2012-12-01

    Full Text Available The paper presents an analysis of SPC (Statistical Process Control procedures usability in foundry engineering. The authors pay particular attention to the processes complexity and necessity of correct preparation of data acquisition procedures. Integration of SPC systems with existing IT solutions in area of aiding and assistance during the manufacturing process is important. For each particular foundry, methodology of selective SPC application needs to prepare for supervision and control of stability of manufacturing conditions, regarding specificity of data in particular “branches” of foundry production (Sands, Pouring, Metallurgy, Quality.

  17. Admittance to specialized palliative care (SPC) of patients with an assessed need

    DEFF Research Database (Denmark)

    Adsersen, Mathilde; Thygesen, Lau Caspar; Neergaard, Mette Asbjoern

    2017-01-01

    BACKGROUND: Admittance to specialized palliative care (SPC) has been discussed in the literature, but previous studies examined exclusively those admitted, not those with an assessed need for SPC but not admitted. The aim was to investigate whether admittance to SPC for referred adult patients...... with cancer was related to sex, age, diagnosis, geographic region or referral unit. MATERIAL AND METHODS: A register-based study with data from the Danish Palliative Care Database (DPD). From DPD we identified all adult patients with cancer, who died in 2010-2012 and who were referred to and assessed to have...

  18. Correlation between k-space sampling pattern and MTF in compressed sensing MRSI.

    Science.gov (United States)

    Heikal, A A; Wachowicz, K; Fallone, B G

    2016-10-01

    To investigate the relationship between the k-space sampling patterns used for compressed sensing MR spectroscopic imaging (CS-MRSI) and the modulation transfer function (MTF) of the metabolite maps. This relationship may allow the desired frequency content of the metabolite maps to be quantitatively tailored when designing an undersampling pattern. Simulations of a phantom were used to calculate the MTF of Nyquist sampled (NS) 32 × 32 MRSI, and four-times undersampled CS-MRSI reconstructions. The dependence of the CS-MTF on the k-space sampling pattern was evaluated for three sets of k-space sampling patterns generated using different probability distribution functions (PDFs). CS-MTFs were also evaluated for three more sets of patterns generated using a modified algorithm where the sampling ratios are constrained to adhere to PDFs. Strong visual correlation as well as high R 2 was found between the MTF of CS-MRSI and the product of the frequency-dependant sampling ratio and the NS 32 × 32 MTF. Also, PDF-constrained sampling patterns led to higher reproducibility of the CS-MTF, and stronger correlations to the above-mentioned product. The relationship established in this work provides the user with a theoretical solution for the MTF of CS MRSI that is both predictable and customizable to the user's needs.

  19. Application of Oversampling to obtain the MTF of Digital Radiology Equipment.

    Science.gov (United States)

    Narváez, M.; Graffigna, J. P.; Gómez, M. E.; Romo, R.

    2016-04-01

    Within the objectives of theproject Medical Image Processing for QualityAssessment ofX Ray Imaging, the present research work is aimed at developinga phantomX ray image and itsassociated processing algorithms in order to evaluatethe image quality rendered by digital X ray equipment. These tools are used to measure various image parameters, among which spatial resolution shows afundamental property that can be characterized by the Modulation Transfer Function (MTF)of an imaging system [1]. After performing a thorough literature surveyon imaging quality control in digital X film in Argentine and international publications, it was decided to adopt for this work the Norm IEC 62220 1:2003 that recommends using an image edge as a testingmethod. In order to obtain the characterizing MTF, a protocol was designedfor unifying the conditions under which the images are acquired for later evaluation. The protocol implied acquiring a radiography image by means of a specific referential technique, i.e. referred either to voltage, current, time, distance focus plate (/film?) distance, or other referential parameter, and to interpret the image through a system of computed radiology or direct digital radiology. The contribution of the work stems from the fact that, even though the traditional way of evaluating an X film image quality has relied mostly on subjective methods, this work presents an objective evaluative toolfor the images obtained with a givenequipment, followed by a contrastive analysis with the renderings from other X filmimaging sets.Once the images were obtained, specific calculations were carried out. Though there exist some methods based on the subjective evaluation of the quality of image, this work offers an objective evaluation of the equipment under study. Finally, we present the results obtained on different equipment.

  20. Application of Oversampling to obtain the MTF of Digital Radiology Equipment

    International Nuclear Information System (INIS)

    Narváez, M.; Graffigna, J. P.; Gómez, M. E.; Romo, R.

    2016-01-01

    Within the objectives of theproject Medical Image Processing for QualityAssessment ofX Ray Imaging, the present research work is aimed at developinga phantomX ray image and itsassociated processing algorithms in order to evaluatethe image quality rendered by digital X ray equipment. These tools are used to measure various image parameters, among which spatial resolution shows afundamental property that can be characterized by the Modulation Transfer Function (MTF)of an imaging system [1]. After performing a thorough literature surveyon imaging quality control in digital X film in Argentine and international publications, it was decided to adopt for this work the Norm IEC 62220 1:2003 that recommends using an image edge as a testingmethod. In order to obtain the characterizing MTF, a protocol was designedfor unifying the conditions under which the images are acquired for later evaluation. The protocol implied acquiring a radiography image by means of a specific referential technique, i.e. referred either to voltage, current, time, distance focus plate (/film?) distance, or other referential parameter, and to interpret the image through a system of computed radiology or direct digital radiology. The contribution of the work stems from the fact that, even though the traditional way of evaluating an X film image quality has relied mostly on subjective methods, this work presents an objective evaluative toolfor the images obtained with a givenequipment, followed by a contrastive analysis with the renderings from other X filmimaging sets.Once the images were obtained, specific calculations were carried out. Though there exist some methods based on the subjective evaluation of the quality of image, this work offers an objective evaluation of the equipment under study. Finally, we present the results obtained on different equipment. (paper)

  1. Project W-314 Polyurea Special Protective Coating (SPC) Test Plan Chemical Compatibility and Physical Characteristics Testing

    International Nuclear Information System (INIS)

    MAUSER, R.W.

    2001-01-01

    This Test Plan outlines the testing to be done on the Special Protective Coating (SPC) Polyurea which includes: Tank Waste Compatibility, Decontamination Factor Testing, and Adhesion Strength Testing after a sample has been exposed to Radiation

  2. GPM GROUND VALIDATION NOAA UHF 449 PROFILER RAW DATA SPC FORMAT MC3E V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The NOAA UHF 449 Profiler Raw SPC foramt data was collected during the NASA supported Midlatitude Continental Convective Clouds Experiment (MC3E). The Ultra High...

  3. GPM GROUND VALIDATION NOAA UHF 449 PROFILER RAW DATA SPC FORMAT MC3E V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation NOAA UHF 449 Profiler Raw Data SPC Format MC3E dataset was collected during the NASA supported Midlatitude Continental Convective Clouds...

  4. Review of the atmospheric propagation in the SPC codes. A progress report

    International Nuclear Information System (INIS)

    Wuebbles, D.J.; Connell, P.S.; Ipser, J.R.; Porch, W.M.; Rosen, L.C.; Knox, J.B.

    1986-10-01

    This is an initial progress report describing findings in critically analyzing and evaluating the atmospheric propagation submodels in the SPC1 and SPC2 models. These systems performance codes were developed by United Technologies Research Center as general purpose, end-to-end models for determining the overall effects on propagation of a laser beam from its source, either from the earth's surface or from an airborne platform, to a target. The SPC1 model is a trimmed down version of SPC2, while including the same coding for atmospheric propagation effects. As with other system models, the SPC codes attempt to include all essential processes to an accuracy commensurate with the use of the models for overall systems analysis and examination of system deployment scenarios. A basic conclusion of our study is that the SPC codes do appear to provide an appropriate framework for end-to-end model studies determining the overall impact of atmospheric effects on laser beam propagation. Nonetheless, our preliminary analysis has discovered a number of errors and limitations to the existing models. The modular structure of the codes will be an important benefit in making necessary improvements. 30 refs., 15 figs., 4 tabs

  5. Homogeneous SPC/E water nucleation in large molecular dynamics simulations.

    Science.gov (United States)

    Angélil, Raymond; Diemand, Jürg; Tanaka, Kyoko K; Tanaka, Hidekazu

    2015-08-14

    We perform direct large molecular dynamics simulations of homogeneous SPC/E water nucleation, using up to ∼ 4 ⋅ 10(6) molecules. Our large system sizes allow us to measure extremely low and accurate nucleation rates, down to ∼ 10(19) cm(-3) s(-1), helping close the gap between experimentally measured rates ∼ 10(17) cm(-3) s(-1). We are also able to precisely measure size distributions, sticking efficiencies, cluster temperatures, and cluster internal densities. We introduce a new functional form to implement the Yasuoka-Matsumoto nucleation rate measurement technique (threshold method). Comparison to nucleation models shows that classical nucleation theory over-estimates nucleation rates by a few orders of magnitude. The semi-phenomenological nucleation model does better, under-predicting rates by at worst a factor of 24. Unlike what has been observed in Lennard-Jones simulations, post-critical clusters have temperatures consistent with the run average temperature. Also, we observe that post-critical clusters have densities very slightly higher, ∼ 5%, than bulk liquid. We re-calibrate a Hale-type J vs. S scaling relation using both experimental and simulation data, finding remarkable consistency in over 30 orders of magnitude in the nucleation rate range and 180 K in the temperature range.

  6. Bulk flow in the combined 2MTF and 6dFGSv surveys

    Science.gov (United States)

    Qin, Fei; Howlett, Cullan; Staveley-Smith, Lister; Hong, Tao

    2018-04-01

    We create a combined sample of 10,904 late and early-type galaxies from the 2MTF and 6dFGSv surveys in order to accurately measure bulk flow in the local Universe. Galaxies and groups of galaxies common between the two surveys are used to verify that the difference in zero-points is <0.02 dex. We introduce a new maximum likelihood estimator (ηMLE) for bulk flow measurements which allows for more accurate measurement in the presence non-Gaussian measurement errors. To calibrate out residual biases due to the subtle interaction of selection effects, Malmquist bias and anisotropic sky distribution, the estimator is tested on mock catalogues generated from 16 independent large-scale GiggleZ and SURFS simulations. The bulk flow of the local Universe using the combined data set, corresponding to a scale size of 40 h-1 Mpc, is 288 ± 24 km s-1 in the direction (l, b) = (296 ± 6°, 21 ± 5°). This is the most accurate bulk flow measurement to date, and the amplitude of the flow is consistent with the ΛCDM expectation for similar size scales.

  7. MTF Driven by Plasma Liner Dynamically Formed by the Merging of Plasma Jets: An Overview

    Science.gov (United States)

    Thio, Y. C. Francis; Eskridge, Richard; Martin, Adam; Smith, James; Lee, Michael; Rodgers, Stephen L. (Technical Monitor)

    2001-01-01

    One approach for standoff delivery of the momentum flux for compressing the target in MTF consists of using a spherical array of plasma jets to form a spherical plasma shell imploding towards the center of a magnetized plasma, a compact toroid (Figure 1). A 3-year experiment (PLX-1) to explore the physics of forming a 2-D plasma liner (shell) by merging plasma jets is described. An overview showing how this 3-year project (PLX-1) fits into the program plan at the national and international level for realizing MTF for energy and propulsion is discussed. Assuming that there will be a parallel program in demonstrating and establishing the underlying physics principles of MTF using whatever liner is appropriate (e.g. a solid liner) with a goal of demonstrating breakeven by 2010, the current research effort at NASA MSFC attempts to complement such a program by addressing the issues of practical embodiment of MTF for propulsion. Successful conclusion of PLX-1 will be followed by a Physics Feasibility Experiment (PLX-2) for the Plasma Liner Driven MTF.

  8. HIV Prevalence and Risk Behaviors in Male to Female (MTF) Transgender Persons in Tijuana, Mexico.

    Science.gov (United States)

    Salas-Espinoza, Kristian Jesús; Menchaca-Diaz, Rufino; Patterson, Thomas L; Urada, Lianne A; Smith, Davey; Strathdee, Steffanie A; Pitpitan, Eileen V

    2017-12-01

    Compared to HIV research on men who have sex with men, less is known about the risks and vulnerabilities for HIV among Male to Female (MTF) transgender persons, particularly in different geographic regions like Mexico. In Tijuana, Mexico, a border city experiencing a dynamic HIV epidemic, no precedent data exists on the MTF transgender population. Our aims were to estimate HIV prevalence and examine the behaviors and characteristics of the population. We conducted a cross-sectional study of 100 MTF transgender persons recruited through time location sampling in 2012. Participants underwent interviewer-administered (paper and pen) surveys and rapid tests for HIV. Descriptive univariate analyses were conducted on various factors, including sociodemographics, substance use, accessing social services (requested vs. received), stigma, and sex behaviors. A total of 22% tested positive for HIV, a prevalence higher than other key populations at risk for HIV in Tijuana.

  9. Intrinsic structural differences in the N-terminal segment of pulmonary surfactant protein SP-C from different species

    DEFF Research Database (Denmark)

    Plasencia, I; Rivas, L; Casals, C

    2001-01-01

    Predictive studies suggest that the known sequences of the N-terminal segment of surfactant protein SP-C from animal species have an intrinsic tendency to form beta-turns, but there are important differences on the probable location of these motifs in different SP-C species. Our hypothesis...

  10. New flood risk index in tropical area generated by using SPC ...

    African Journals Online (AJOL)

    This study applied four hydrology parameters. The findings from Principal Component Analysis confirmed that all selected parameters were significant to be taken as main tools for further analysis with result of R2> 0.7. SPC set up a new control limit for all selected parameters in the study area. For those data within or ...

  11. Characterization of the Leptospira interrogans S10-spc-alpha operon

    NARCIS (Netherlands)

    Zuerner, R. L.; Hartskeerl, R. A.; van de Kemp, H.; Bal, A. E.

    2000-01-01

    A ribosomal protein gene cluster from the spirochaete Leptospira interrogans was characterized. This locus is homologous to the Escherichia coli S10, spc, and alpha operons. Analysis of L. interrogans RNA showed that the ribosomal protein genes within this cluster are co-transcribed, thus forming an

  12. Selective labeling of pulmonary surfactant protein SP-C in organic solution

    DEFF Research Database (Denmark)

    Plasencia, I; Cruz, A; López-Lacomba, J L

    2001-01-01

    Pulmonary surfactant protein SP-C has been isolated from porcine lungs and treated with dansyl isothiocyanate in chloroform:methanol 2:1 (v/v) solutions,under conditions optimized to introduce a single dansyl group covalently attached to the N-terminalamine group of the protein without loss of its...

  13. SpcAudace: Spectroscopic processing and analysis package of Audela software

    Science.gov (United States)

    Mauclaire, Benjamin

    2017-11-01

    SpcAudace processes long slit spectra with automated pipelines and performs astrophysical analysis of the latter data. These powerful pipelines do all the required steps in one pass: standard preprocessing, masking of bad pixels, geometric corrections, registration, optimized spectrum extraction, wavelength calibration and instrumental response computation and correction. Both high and low resolution long slit spectra are managed for stellar and non-stellar targets. Many types of publication-quality figures can be easily produced: pdf and png plots or annotated time series plots. Astrophysical quantities can be derived from individual or large amount of spectra with advanced functions: from line profile characteristics to equivalent width and periodogram. More than 300 documented functions are available and can be used into TCL scripts for automation. SpcAudace is based on Audela open source software.

  14. Project W-314 Polyurea Special Protective Coating (SPC) Test Report Chemical Compatibility and Physical Characteristics Testing

    International Nuclear Information System (INIS)

    MAUSER, R.W.

    2001-01-01

    This Engineering Test report outlines the results obtained from testing polyurea on its decon factor, tank waste compatibility, and adhesion strength when subjected to a high level of gamma radiation. This report is used in conjunction with RPP-7187 Project W-314 Pit Coatings Repair Requirements Analysis, to document the fact polyurea meets the project W-314 requirements contained in HNF-SD-W314-PDS-005 and is therefore an acceptable SPC for use in W-314 pit refurbishments

  15. TU-F-18C-07: Hardware Advances for MTF Improvement in Dedicated Breast CT

    International Nuclear Information System (INIS)

    Gazi, P; Burkett, G; Yang, K; Boone, J

    2014-01-01

    Purpose: In this study, we have designed and implemented a prototype dedicated breast CT system (bCT) to improve the spatial resolution characteristics, in order to improve detection of micro-calcifications. Methods: A 10.8 kW water-cooled, tungsten anode x-ray tube, running up to 240 mA at 60 kV, coupled with an x-ray generator specifically designed for this application, and 0.3 mm of added copper filter was used to generate x-ray pulses. A CsI CMOS flat panel detector with a pixel pitch of 0.075 mm in native binning mode was used. The system geometry was designed in a way to achieve an FOV on par with similar bCT prototypes, resulting in a magnification factor of 1.39. A 0.013 mm tungsten wire was used to generate point spread functions. Multiple scans were performed with different numbers of projections, different reconstruction kernel sizes and different reconstruction filters to study the effects of each parameter on MTF. The resulting MTFs were then evaluated quantitatively using the generated PFSs. Duplicate scans with the same parameters were performed on two other dedicated breast CT systems to compare the performance of the new prototype. Results: The results of the MTF experiments demonstrate a significant improvement in the spatial resolution characteristics. In the new prototype, using the pulsed x-ray source results in a restoration of the azimuthal MTF degradation, due to motion blurring previously seen in other bCT systems. Moreover, employing the higher resolution x-ray detector considerably improves the MTF. The MTF at 10% of the new system is at 3.5 1/mm, a factor of 4.36 greater than an earlier bCT scanner. Conclusion: The MTF analysis of the new prototype bCT shows that using the new hardware and control results in a significant improvement in visualization of finer detail. This suggests that the visualization of micro-calcifications will be significantly improved

  16. A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC)

    Energy Technology Data Exchange (ETDEWEB)

    Gerard, Karine; Grandhaye, Jean-Pierre; Marchesi, Vincent; Kafrouni, Hanna; Husson, Francois; Aletti, Pierre [Research Center for Automatic Control (CRAN), Nancy University, CNRS, 54516 Vandoeuvre-les-Nancy (France); Department of Medical Physics, Alexis Vautrin Cancer Center, 54511 Vandoeuvre-les-Nancy Cedex (France) and DOSIsoft SA, 94230 Cachan (France); Research Laboratory for Innovative Processes (ERPI), Nancy University, EA 3767, 5400 Nancy Cedex (France); Department of Medical Physics, Alexis Vautrin Cancer Center, 54511 Vandoeuvre-les-Nancy Cedex (France); DOSIsoft SA, 94230 Cachan (France); Research Center for Automatic Control (CRAN), Nancy University, CNRS, 54516 Vandoeuvre-les-Nancy, France and Department of Medical Physics, Alexis Vautrin Cancer Center, 54511 Vandoeuvre-les-Nancy Cedex (France)

    2009-04-15

    The aim of this study is to introduce tools to improve the security of each IMRT patient treatment by determining action levels for the dose delivery process. To achieve this, the patient-specific quality control results performed with an ionization chamber--and which characterize the dose delivery process--have been retrospectively analyzed using a method borrowed from industry: Statistical process control (SPC). The latter consisted in fulfilling four principal well-structured steps. The authors first quantified the short term variability of ionization chamber measurements regarding the clinical tolerances used in the cancer center ({+-}4% of deviation between the calculated and measured doses) by calculating a control process capability (C{sub pc}) index. The C{sub pc} index was found superior to 4, which implies that the observed variability of the dose delivery process is not biased by the short term variability of the measurement. Then, the authors demonstrated using a normality test that the quality control results could be approximated by a normal distribution with two parameters (mean and standard deviation). Finally, the authors used two complementary tools--control charts and performance indices--to thoroughly analyze the IMRT dose delivery process. Control charts aim at monitoring the process over time using statistical control limits to distinguish random (natural) variations from significant changes in the process, whereas performance indices aim at quantifying the ability of the process to produce data that are within the clinical tolerances, at a precise moment. The authors retrospectively showed that the analysis of three selected control charts (individual value, moving-range, and EWMA control charts) allowed efficient drift detection of the dose delivery process for prostate and head-and-neck treatments before the quality controls were outside the clinical tolerances. Therefore, when analyzed in real time, during quality controls, they should

  17. A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC).

    Science.gov (United States)

    Gérard, Karine; Grandhaye, Jean-Pierre; Marchesi, Vincent; Kafrouni, Hanna; Husson, François; Aletti, Pierre

    2009-04-01

    The aim of this study is to introduce tools to improve the security of each IMRT patient treatment by determining action levels for the dose delivery process. To achieve this, the patient-specific quality control results performed with an ionization chamber--and which characterize the dose delivery process--have been retrospectively analyzed using a method borrowed from industry: Statistical process control (SPC). The latter consisted in fulfilling four principal well-structured steps. The authors first quantified the short-term variability of ionization chamber measurements regarding the clinical tolerances used in the cancer center (+/- 4% of deviation between the calculated and measured doses) by calculating a control process capability (C(pc)) index. The C(pc) index was found superior to 4, which implies that the observed variability of the dose delivery process is not biased by the short-term variability of the measurement. Then, the authors demonstrated using a normality test that the quality control results could be approximated by a normal distribution with two parameters (mean and standard deviation). Finally, the authors used two complementary tools--control charts and performance indices--to thoroughly analyze the IMRT dose delivery process. Control charts aim at monitoring the process over time using statistical control limits to distinguish random (natural) variations from significant changes in the process, whereas performance indices aim at quantifying the ability of the process to produce data that are within the clinical tolerances, at a precise moment. The authors retrospectively showed that the analysis of three selected control charts (individual value, moving-range, and EWMA control charts) allowed efficient drift detection of the dose delivery process for prostate and head-and-neck treatments before the quality controls were outside the clinical tolerances. Therefore, when analyzed in real time, during quality controls, they should improve the

  18. Application of Statistical Process Control (SPC in it´s Quality control

    Directory of Open Access Journals (Sweden)

    Carlos Hernández-Pedrera

    2015-12-01

    Full Text Available The overall objective of this paper is to use the SPC to assess the possibility of improving the process of obtaining a sanitary device. As specific objectives we set out to identify the variables to be analyzed to enter the statistical control of process (SPC, analyze possible errors and variations indicated by the control charts in addition to evaluate and compare the results achieved with the study of SPC before and after monitoring direct in the production line were used sampling methods and laboratory replacement to determine the quality of the finished product, then statistical methods were applied seeking to emphasize the importance and contribution from its application to monitor corrective actions and support processes in production. It was shown that the process is under control because the results were found within established control limits. There is a tendency to be displaced toward one end of the boundary, the distribution exceeds the limits, creating the possibility that under certain conditions the process is out of control, the results also showed that the process being within the limits of quality control is operating far from the optimal conditions. In any of the study situations were obtained products outside the limits of weight and discoloration but defective products were obtained.

  19. Plasma Liner Research for MTF at NASA Marshall Space Flight Center

    Science.gov (United States)

    Thio, Y. C. F.; Eskridge, R.; Lee, M.; Martin, A.; Smith, J.; Cassibry, J. T.; Wu, S. T.; Kirkpatrick, R. C.; Knapp, C. E.; Turchi, P. J.; hide

    2002-01-01

    The current research effort at NASA Marshall Space Flight Center (MSFC) in MTF is directed towards exploring the critical physics issues of potential embodiments of MTF for propulsion, especially standoff drivers involving plasma liners for MTF. There are several possible approaches for forming plasma liners. One approach consists of using a spherical array of plasma jets to form a spherical plasma shell imploding towards the center of a magnetized plasma, a compact toroid. Current experimental plan and status to explore the physics of forming a 2-D plasma liner (shell) by merging plasma jets are described. A first-generation coaxial plasma guns (Mark-1) to launch the required plasma jets have been built and tested. Plasma jets have been launched reproducibly with a low jitter, and velocities in excess of 50 km/s for the leading edge of the plasma jet. Some further refinements are being explored for the plasma gun, Successful completion of these single-gun tests will be followed by an experimental exploration of the problems of launching a multiple number of these jets simultaneously to form a cylindrical plasma liner.

  20. One-dimensional MHD simulations of MTF systems with compact toroid targets and spherical liners

    Science.gov (United States)

    Khalzov, Ivan; Zindler, Ryan; Barsky, Sandra; Delage, Michael; Laberge, Michel

    2017-10-01

    One-dimensional (1D) MHD code is developed in General Fusion (GF) for coupled plasma-liner simulations in magnetized target fusion (MTF) systems. The main goal of these simulations is to search for optimal parameters of MTF reactor, in which spherical liquid metal liner compresses compact toroid plasma. The code uses Lagrangian description for both liner and plasma. The liner is represented as a set of spherical shells with fixed masses while plasma is discretized as a set of nested tori with circular cross sections and fixed number of particles between them. All physical fields are 1D functions of either spherical (liner) or small toroidal (plasma) radius. Motion of liner and plasma shells is calculated self-consistently based on applied forces and equations of state. Magnetic field is determined by 1D profiles of poloidal and toroidal fluxes - they are advected with shells and diffuse according to local resistivity, this also accounts for flux leakage into the liner. Different plasma transport models are implemented, this allows for comparison with ongoing GF experiments. Fusion power calculation is included into the code. We performed a series of parameter scans in order to establish the underlying dependencies of the MTF system and find the optimal reactor design point.

  1. SPC3042

    DEFF Research Database (Denmark)

    Hansen, Jens Bo; Fisker, Niels; Westergaard, Majken

    2008-01-01

    The ability to regulate the cellular homeostasis of a higher organism through tight control of apoptosis and cell division is crucial for life. Dysregulation of these mechanisms is often associated with cancerous phenotypes in cells. Optimal cancer therapy is a fine balance between effective canc...

  2. [Study of Image Quality Comparison Based on the MTF Method Between Different Medical Rigid Endoscopes in an In Vitro Model].

    Science.gov (United States)

    Wang, Yunlong; Ji, Jun; Jiang, Changsong; Huang, Zengyue

    2015-04-01

    This study was aimed to use the method of modulation transfer function (MTF) to compare image quality among three different Olympus medical rigid cystoscopes in an in vitro model. During the experimental processes, we firstly used three different types of cystoscopes (i. e. OLYMPUS cystourethroscopy with FOV of 12 degrees, OLYMPUS Germany A22003A and OLYMPUS A2013A) to collect raster images at different brightness with industrial camera and computer from the resolution target which is with different spatial frequency, and then we processed the collected images using MALAB software with the optical transfer function MTF to obtain the values of MTF at different brightness and different spatial frequency. We then did data mathematical statistics and compared imaging quality. The statistical data showed that all three MTF values were smaller than 1. MTF values with the spatial frequency gradually increasing would decrease approaching 0 at the same brightness. When the brightness enhanced in the same process at the same spatial frequency, MTF values showed a slowly increasing trend. The three endoscopes' MTF values were completely different. In some cases the MTF values had a large difference, and the maximum difference could reach 0.7. Conclusion can be derived from analysis of experimental data that three Olympus medical rigid cystoscopes have completely different imaging quality abilities. The No. 3 endoscope OLYMPUS A2013A has low resolution but high contrast. The No. 1 endoscope OLYMPUS cystourethroscopy with FOV of 12 degrees, on the contrary, had high resolution and lower contrast. The No. 2 endoscope OLYMPUS Germany A22003A had high contrast and high resolution, and its image quality was the best.

  3. Effects of hydrophobic helix length and side chain chemistry on biomimicry in peptoid analogues of SP-C.

    Science.gov (United States)

    Brown, Nathan J; Wu, Cindy W; Seurynck-Servoss, Shannon L; Barron, Annelise E

    2008-02-12

    The hydrophobic proteins of lung surfactant (LS), SP-B and SP-C, are critical constituents of an effective surfactant replacement therapy for the treatment of respiratory distress syndrome. Because of concerns and difficulties associated with animal-derived surfactants, recent investigations have focused on the creation of synthetic analogues of the LS proteins. However, creating an accurate mimic of SP-C that retains its biophysical surface activity is extraordinarily challenging given the lipopeptide's extreme hydrophobicity and propensity to misfold and aggregate. One successful approach that overcomes these difficulties is the use of poly-N-substituted glycines, or peptoids, to mimic SP-C. To develop a non-natural, bioactive mimic of SP-C and to investigate the effects of side chain chemistry and length of the helical hydrophobic region, we synthesized, purified, and performed in vitro testing of two classes of peptoid SP-C mimics: those having a rigid alpha-chiral aromatic helix and those having a biomimetic alpha-chiral aliphatic helix. The length of the two classes of mimics was also systematically altered. Circular dichroism spectroscopy gave evidence that all of the peptoid-based mimics studied here emulated SP-C's secondary structure, forming stable helical structures in solution. Langmuir-Wilhelmy surface balance, fluorescence microscopy, and pulsating bubble surfactometry experiments provide evidence that the aromatic-based SP-C peptoid mimics, in conjunction with a synthetic lipid mixture, have superior surface activity and biomimetic film morphology in comparison to the aliphatic-based mimics and that there is an increase in surface activity corresponding to increasing helical length.

  4. Application of machine learning and expert systems to Statistical Process Control (SPC) chart interpretation

    Science.gov (United States)

    Shewhart, Mark

    1991-01-01

    Statistical Process Control (SPC) charts are one of several tools used in quality control. Other tools include flow charts, histograms, cause and effect diagrams, check sheets, Pareto diagrams, graphs, and scatter diagrams. A control chart is simply a graph which indicates process variation over time. The purpose of drawing a control chart is to detect any changes in the process signalled by abnormal points or patterns on the graph. The Artificial Intelligence Support Center (AISC) of the Acquisition Logistics Division has developed a hybrid machine learning expert system prototype which automates the process of constructing and interpreting control charts.

  5. Immobilization of radioactive and hazardous wastes in a newly developed sulfur polymer cement (Spc) matrix

    International Nuclear Information System (INIS)

    Abdel Raouf, M.W.; Husain, A.I.; El-Gammal, B.

    2005-01-01

    Low and Intermediate level radioactive wastes (LILW) and hazardous wastes, presents a waste disposal problem. In this respect, a process to immobilize different radioactive and hazardous wastes, including metals contaminated with radionuclides in a form that is non-dispersible and meet the Environmental Protection Agency (USA, EPA) leaching criteria is a must. In this stabilization and solidification process (S/S), simulated radioactive wastes of Cs, Sr, Ce, Cr, and Pb were immobilized in the stable form of sulfur polymer cement (SPC). In the present work, the mixture of the contaminant(s) and the sulfur mixture which is composed from 95% S and 5% aromatic/or aliphatic hydrocarbons used as polymerizing agents for sulfur (by weight), were added in a stainless steel vessel and primarily heated to 40 degree C for four hours, this time was sufficient for homogeneous mixing of the metals with sulfur and Na 2 S (to convert the metals to their corresponding sulfides). Additional SPC was then added and the temperature of the mixture was raised to 135 ±1 degree C, resulting in a molten form that was poured into a stainless steel mold where it cooled and solidified. Durability of the fabricated SPC matrices was assessed in terms of water of immersion, porosity, and compressive strength. The water absorption and open porosity were very low and didn't exceed 2.5 % for all matrices, whereas the compressive strength ranged between 7 and 14 KN/m 2 depending on the matrix composition. The immobilized waste forms of SPC were characterized by X-ray diffraction (XRD) technique that showed that the different contaminants were stabilized during the solidification process to form stable sulfides. Leachability of the waste matrices was assessed by the Toxicity Characteristic Leaching Procedure (TCLP) of the EPA, optimized and compared with the new EPA Universal Treatment Standards.The TCLP results showed that the concentration of the most contaminants released were under detection limit

  6. Transcription factor CgMTF-1 regulates CgZnT1 and CgMT expression in Pacific oyster (Crassostrea gigas) under zinc stress

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Jie; Zhang, Linlin [Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071, Shandong (China); Li, Li, E-mail: lili@qdio.ac.cn [Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071, Shandong (China); Li, Chunyan; Wang, Ting [Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071, Shandong (China); University of Chinese Academy of Sciences, Beijing 100039 (China); Zhang, Guofan, E-mail: gfzhang@qdio.ac.cn [Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071, Shandong (China)

    2015-08-15

    Highlights: • CgMTF-1 and CgZnT1 were first identified in oysters. • CgMTF-1 localized in cell nucleus under unstressed conditions. • CgMTF-1 proteins could bind with the typical MRE motif. • CgMTF-1 activated CgZnT1, CgMT1 and CgMT4 promoters and regulated their expressions under zinc exposure. - Abstract: Oysters accumulate zinc at high tissue concentrations, and the metal response element (MRE)-binding transcription factor (MTF) functions as the cellular zinc sensor that coordinates the expression of genes involved in zinc efflux and storage, as well as those that protect against metal toxicity. In this study, we cloned MTF-1 in oysters and examined its regulation mechanism for its classic target genes, including MTs and ZnT1 under zinc exposure conditions. We cloned CgMTF-1 and determined the subcellular locations of its protein product in HEK293 cells. CgMTF-1 has a 2826 bp open reading frame that encodes a predicted polypeptide with 707 amino acid residues, showing six well-conserved zinc finger domains that are required for metal binding. In HEK293 cell lines, CgMTF-1 primarily localizes in the cell nucleus under unstressed conditions and nuclear translocation was not critical for the activation of this gene. We searched for CgMTF-1-regulated genes in oysters using RNA interference. Decreased expression levels of CgMT1, CgMT4, and CgZnT1 were observed after CgMTF-1 interference (>70% inhibition) under zinc exposure, indicating the critical role of CgMTF-1 in the regulation of these genes. We searched for a direct regulation mechanism involving CgMTF-1 for CgMT1, CgMT4, and CgZnT1 in vitro. EMSA experiments indicated that CgMTF-1 can bind with the MREs found in the CgZnT1, CgMT1 and CgMT4 promoter regions. Additionally, luciferase reporter gene experiments indicated that CgMTF-1 could activate the CgMT1, CgMT4, and CgZnT1 promoters. Overall, our results suggest that CgMTF-1 directly coordinates the regulation of CgMTs and CgZnT1 expression and plays

  7. Transcription factor CgMTF-1 regulates CgZnT1 and CgMT expression in Pacific oyster (Crassostrea gigas) under zinc stress

    International Nuclear Information System (INIS)

    Meng, Jie; Zhang, Linlin; Li, Li; Li, Chunyan; Wang, Ting; Zhang, Guofan

    2015-01-01

    Highlights: • CgMTF-1 and CgZnT1 were first identified in oysters. • CgMTF-1 localized in cell nucleus under unstressed conditions. • CgMTF-1 proteins could bind with the typical MRE motif. • CgMTF-1 activated CgZnT1, CgMT1 and CgMT4 promoters and regulated their expressions under zinc exposure. - Abstract: Oysters accumulate zinc at high tissue concentrations, and the metal response element (MRE)-binding transcription factor (MTF) functions as the cellular zinc sensor that coordinates the expression of genes involved in zinc efflux and storage, as well as those that protect against metal toxicity. In this study, we cloned MTF-1 in oysters and examined its regulation mechanism for its classic target genes, including MTs and ZnT1 under zinc exposure conditions. We cloned CgMTF-1 and determined the subcellular locations of its protein product in HEK293 cells. CgMTF-1 has a 2826 bp open reading frame that encodes a predicted polypeptide with 707 amino acid residues, showing six well-conserved zinc finger domains that are required for metal binding. In HEK293 cell lines, CgMTF-1 primarily localizes in the cell nucleus under unstressed conditions and nuclear translocation was not critical for the activation of this gene. We searched for CgMTF-1-regulated genes in oysters using RNA interference. Decreased expression levels of CgMT1, CgMT4, and CgZnT1 were observed after CgMTF-1 interference (>70% inhibition) under zinc exposure, indicating the critical role of CgMTF-1 in the regulation of these genes. We searched for a direct regulation mechanism involving CgMTF-1 for CgMT1, CgMT4, and CgZnT1 in vitro. EMSA experiments indicated that CgMTF-1 can bind with the MREs found in the CgZnT1, CgMT1 and CgMT4 promoter regions. Additionally, luciferase reporter gene experiments indicated that CgMTF-1 could activate the CgMT1, CgMT4, and CgZnT1 promoters. Overall, our results suggest that CgMTF-1 directly coordinates the regulation of CgMTs and CgZnT1 expression and plays

  8. Industrial implementation of spatial variability control by real-time SPC

    Science.gov (United States)

    Roule, O.; Pasqualini, F.; Borde, M.

    2016-10-01

    Advanced technology nodes require more and more information to get the wafer process well setup. The critical dimension of components decreases following Moore's law. At the same time, the intra-wafer dispersion linked to the spatial non-uniformity of tool's processes is not capable to decrease in the same proportions. APC systems (Advanced Process Control) are being developed in waferfab to automatically adjust and tune wafer processing, based on a lot of process context information. It can generate and monitor complex intrawafer process profile corrections between different process steps. It leads us to put under control the spatial variability, in real time by our SPC system (Statistical Process Control). This paper will outline the architecture of an integrated process control system for shape monitoring in 3D, implemented in waferfab.

  9. Performance analysis of different tuning rules for an isothermal CSTR using integrated EPC and SPC

    Science.gov (United States)

    Roslan, A. H.; Karim, S. F. Abd; Hamzah, N.

    2018-03-01

    This paper demonstrates the integration of Engineering Process Control (EPC) and Statistical Process Control (SPC) for the control of product concentration of an isothermal CSTR. The objectives of this study are to evaluate the performance of Ziegler-Nichols (Z-N), Direct Synthesis, (DS) and Internal Model Control (IMC) tuning methods and determine the most effective method for this process. The simulation model was obtained from past literature and re-constructed using SIMULINK MATLAB to evaluate the process response. Additionally, the process stability, capability and normality were analyzed using Process Capability Sixpack reports in Minitab. Based on the results, DS displays the best response for having the smallest rise time, settling time, overshoot, undershoot, Integral Time Absolute Error (ITAE) and Integral Square Error (ISE). Also, based on statistical analysis, DS yields as the best tuning method as it exhibits the highest process stability and capability.

  10. Review of Reliability Assessment of Westinghouse SSPS Using SPC by WEC

    International Nuclear Information System (INIS)

    Kang, H. T.; Chung, H. Y.

    2007-01-01

    Westinghouse Electric Company (WEC) has accomplished the reliability assessment of Westinghouse Solid State Protection System (SSPS) in KORI no. 2, 3, 4, and YGN no. 1, 2. In their studies, it is reported that creating a cost-effective plan for improving the reliability of the SSPS and at KORI no. 2, 3 and 4, and YGN no. 1, 2 should be needed while reducing their maintenance cost. In this paper, we reviewed the reliability assessment of Westinghouse SSPS analyzed in two performance standards, availability, and the maintenance expense using Statistic Process Control (SPC). As a result, it is concluded all plants have several failures reported but no effect on the system's availability, and the maintenance expense analysis did not reduce the current maintenance expense by 30%. Therefore, overall review for the reliability assessment is that a new strategy for cost-effective plan and/or upgrade approach for improving the reliability of the aging Westinghouse SSPS should be needed

  11. Associations between the Transsexual Voice Questionnaire (TVQMtF ) and self-report of voice femininity and acoustic voice measures.

    Science.gov (United States)

    Dacakis, Georgia; Oates, Jennifer; Douglas, Jacinta

    2017-11-01

    The Transsexual Voice Questionnaire (TVQ MtF ) was designed to capture the voice-related perceptions of individuals whose gender identity as female is the opposite of their birth-assigned gender (MtF women). Evaluation of the psychometric properties of the TVQ MtF is ongoing. To investigate associations between TVQ MtF scores and (1) self-perceptions of voice femininity and (2) acoustic parameters of voice pitch and voice quality in order to evaluate further the validity of the TVQ MtF . A strong correlation between TVQ MtF scores and self-ratings of voice femininity was predicted, but no association between TVQ MtF scores and acoustic measures of voice pitch and quality was proposed. Participants were 148 MtF women (mean age 48.14 years) recruited from the La Trobe Communication Clinic and the clinics of three doctors specializing in transgender health. All participants completed the TVQ MtF and 34 of these participants also provided a voice sample for acoustic analysis. Pearson product-moment correlation analysis was conducted to examine the associations between TVQ MtF scores and (1) self-perceptions of voice femininity and (2) acoustic measures of F0, jitter (%), shimmer (dB) and harmonic-to-noise ratio (HNR). Strong negative correlations between the participants' perceptions of their voice femininity and the TVQ MtF scores demonstrated that for this group of MtF women a low self-rating of voice femininity was associated with more frequent negative voice-related experiences. This association was strongest with the vocal-functioning component of the TVQ MtF . These strong correlations and high levels of shared variance between the TVQ MtF and a measure of a related construct provides evidence for the convergent validity of the TVQ MtF . The absence of significant correlations between the TVQ MtF and the acoustic data is consistent with the equivocal findings of earlier research. This finding indicates that these two measures assess different aspects of the voice

  12. Interaction of the N-terminal segment of pulmonary surfactant protein SP-C with interfacial phospholipid films

    DEFF Research Database (Denmark)

    Plasencia, Inés; Keough, Kevin M W; Perez-Gil, Jesus

    2005-01-01

    Pulmonary surfactant protein SP-C is a 35-residue polypeptide composed of a hydrophobic transmembrane alpha-helix and a polycationic, palmitoylated-cysteine containing N-terminal segment. This segment is likely the only structural motif the protein projects out of the bilayer in which SP-C is ins......Pulmonary surfactant protein SP-C is a 35-residue polypeptide composed of a hydrophobic transmembrane alpha-helix and a polycationic, palmitoylated-cysteine containing N-terminal segment. This segment is likely the only structural motif the protein projects out of the bilayer in which SP...... or anionic phospholipid monolayers. The peptide expands the pi-A compression isotherms of interfacial phospholipid/peptide films, and perturbs the lipid packing of phospholipid films during compression-driven liquid-expanded to liquid-condensed lateral transitions, as observed by epifluorescence microscopy....... These results demonstrate that the sequence of the SP-C N-terminal region has intrinsic ability to interact with, insert into, and perturb the structure of zwitterionic and anionic phospholipid films, even in the absence of the palmitic chains attached to this segment in the native protein. This effect has been...

  13. An optimized knife-edge method for on-orbit MTF estimation of optical sensors using powell parameter fitting

    Science.gov (United States)

    Han, Lu; Gao, Kun; Gong, Chen; Zhu, Zhenyu; Guo, Yue

    2017-08-01

    On-orbit Modulation Transfer Function (MTF) is an important indicator to evaluate the performance of the optical remote sensors in a satellite. There are many methods to estimate MTF, such as pinhole method, slit method and so on. Among them, knife-edge method is quite efficient, easy-to-use and recommended in ISO12233 standard for the wholefrequency MTF curve acquisition. However, the accuracy of the algorithm is affected by Edge Spread Function (ESF) fitting accuracy significantly, which limits the range of application. So in this paper, an optimized knife-edge method using Powell algorithm is proposed to improve the ESF fitting precision. Fermi function model is the most popular ESF fitting model, yet it is vulnerable to the initial values of the parameters. Considering the characteristics of simple and fast convergence, Powell algorithm is applied to fit the accurate parameters adaptively with the insensitivity to the initial parameters. Numerical simulation results reveal the accuracy and robustness of the optimized algorithm under different SNR, edge direction and leaning angles conditions. Experimental results using images of the camera in ZY-3 satellite show that this method is more accurate than the standard knife-edge method of ISO12233 in MTF estimation.

  14. Image Quality Assessment of High-Resolution Satellite Images with Mtf-Based Fuzzy Comprehensive Evaluation Method

    Science.gov (United States)

    Wu, Z.; Luo, Z.; Zhang, Y.; Guo, F.; He, L.

    2018-04-01

    A Modulation Transfer Function (MTF)-based fuzzy comprehensive evaluation method was proposed in this paper for the purpose of evaluating high-resolution satellite image quality. To establish the factor set, two MTF features and seven radiant features were extracted from the knife-edge region of image patch, which included Nyquist, MTF0.5, entropy, peak signal to noise ratio (PSNR), average difference, edge intensity, average gradient, contrast and ground spatial distance (GSD). After analyzing the statistical distribution of above features, a fuzzy evaluation threshold table and fuzzy evaluation membership functions was established. The experiments for comprehensive quality assessment of different natural and artificial objects was done with GF2 image patches. The results showed that the calibration field image has the highest quality scores. The water image has closest image quality to the calibration field, quality of building image is a little poor than water image, but much higher than farmland image. In order to test the influence of different features on quality evaluation, the experiment with different weights were tested on GF2 and SPOT7 images. The results showed that different weights correspond different evaluating effectiveness. In the case of setting up the weights of edge features and GSD, the image quality of GF2 is better than SPOT7. However, when setting MTF and PSNR as main factor, the image quality of SPOT7 is better than GF2.

  15. Pengendalian Kualitas Produk Di Industri Garment Dengan Menggunakan Statistical Procces Control (SPC

    Directory of Open Access Journals (Sweden)

    Rizal Rachman

    2017-09-01

    Full Text Available Abstrak Perusahaan memandang bahwa kualitas sebagai faktor kunci yang membawa keberhasilan dan standar mutu yang telah ditetapkan oleh buyer. Tujuan penelitian ini adalah untuk mengetahui tingkat kerusakan produk dalam batas pengendalian kualitas pada proses produksi pakaian jadi pada PT. Asia Penta Garment. Penelitian ini menggunakan metode statistical procces control. Data yang diambil dalam penelitian ini mengunakan data sekunder berupa laporan jumlah produksi dan kerusakan pakaian jadi di bagian finishing pada Januari 2017. Berdasarkan hasil menunjukkan kerusakan diluar batas pengendalian yaitu ada yang diluar batas kendali (out of control dengan batas pengendalian atas (UCL dan batas pengendalian bawah (LCL dan rata-rata kerusakan diluar batas kendali.Untuk meningkatkan kualitas produk khususnya pakaian yang dihasilkan perusahaan, kebijakan mutu yang telah ditetapkan harus dijalankan dengan benar, antara lain dalam pemilihan negoisasi bahan baku dengan buyer sesuai standar, perekrutan tenaga kerja yang berpengalaman, kedisiplinan kerja yang tinggi, pembinaan para karyawan, pemberian bonus pada karyawan yang sesuai target dan disiplin tinggi, perbaikan mesin secara terus menerus dan memperbaiki lingkungan kerja yang bersih, nyaman, serta aman.   Kata Kunci : Pengendalian kualitas, Kualitas produk, SPC. Abstract The Company considers that quality as a key factor that brings success and quality standards set by the buyer. The purpose of this study was to determine the level of damage to the product within the limits of quality control in the production process apparel in PT. Asia Penta Garment. This study uses a statistical procces control methode. Data taken in this study using secondary data from reports on the number of production and damage to clothing in the finishing section in January 2017. Based on the results show the damage outside the control limits is nothing beyond the control limit (out of control with the upper control limit

  16. A Novel Method for Preparing Auxetic Foam from Closed-cell Polymer Foam Based on Steam Penetration and Condensation (SPC) Process.

    Science.gov (United States)

    Fan, Donglei; Li, Minggang; Qiu, Jian; Xing, Haiping; Jiang, Zhiwei; Tang, Tao

    2018-05-31

    Auxetic materials are a class of materials possessing negative Poisson's ratio. Here we establish a novel method for preparing auxetic foam from closed-cell polymer foam based on steam penetration and condensation (SPC) process. Using polyethylene (PE) closed-cell foam as an example, the resultant foams treated by SPC process present negative Poisson's ratio during stretching and compression testing. The effect of steam-treated temperature and time on the conversion efficiency of negative Poisson's ratio foam is investigated, and the mechanism of SPC method for forming re-entrant structure is discussed. The results indicate that the presence of enough steam within the cells is a critical factor for the negative Poisson's ratio conversion in the SPC process. The pressure difference caused by steam condensation is the driving force for the conversion from conventional closed-cell foam to the negative Poisson's ratio foam. Furthermore, the applicability of SPC process for fabricating auxetic foam is studied by replacing PE foam by polyvinyl chloride (PVC) foam with closed-cell structure or replacing water steam by ethanol steam. The results verify the universality of SPC process for fabricating auxetic foams from conventional foams with closed-cell structure. In addition, we explored potential application of the obtained auxetic foams by SPC process in the fabrication of shape memory polymer materials.

  17. Seasonal ARMA-based SPC charts for anomaly detection: Application to emergency department systems

    KAUST Repository

    Kadri, Farid

    2015-10-22

    Monitoring complex production systems is primordial to ensure management, reliability and safety as well as maintaining the desired product quality. Early detection of emergent abnormal behaviour in monitored systems allows pre-emptive action to prevent more serious consequences, to improve system operations and to reduce manufacturing and/or service costs. This study reports the design of a new methodology for the detection of abnormal situations based on the integration of time-series analysis models and statistical process control (SPC) tools for the joint development of a monitoring system to help supervising of the behaviour of emergency department services (EDs). The monitoring system developed is able to provide early alerts in the event of abnormal situations. The seasonal autoregressive moving average (SARMA)-based exponentially weighted moving average (EWMA) anomaly detection scheme proposed was successfully applied to the practical data collected from the database of the paediatric emergency department (PED) at Lille regional hospital centre, France. The method developed utilizes SARMA as a modelling framework and EWMA for anomaly detection. The EWMA control chart is applied to the uncorrelated residuals obtained from the SARMA model. The detection results of the EWMA chart are compared with two other commonly applied residual-based tests: a Shewhart individuals chart and a Cumulative Sum (CUSUM) control chart.

  18. Seasonal ARMA-based SPC charts for anomaly detection: Application to emergency department systems

    KAUST Repository

    Kadri, Farid; Harrou, Fouzi; Chaabane, Sondè s; Sun, Ying; Tahon, Christian

    2015-01-01

    Monitoring complex production systems is primordial to ensure management, reliability and safety as well as maintaining the desired product quality. Early detection of emergent abnormal behaviour in monitored systems allows pre-emptive action to prevent more serious consequences, to improve system operations and to reduce manufacturing and/or service costs. This study reports the design of a new methodology for the detection of abnormal situations based on the integration of time-series analysis models and statistical process control (SPC) tools for the joint development of a monitoring system to help supervising of the behaviour of emergency department services (EDs). The monitoring system developed is able to provide early alerts in the event of abnormal situations. The seasonal autoregressive moving average (SARMA)-based exponentially weighted moving average (EWMA) anomaly detection scheme proposed was successfully applied to the practical data collected from the database of the paediatric emergency department (PED) at Lille regional hospital centre, France. The method developed utilizes SARMA as a modelling framework and EWMA for anomaly detection. The EWMA control chart is applied to the uncorrelated residuals obtained from the SARMA model. The detection results of the EWMA chart are compared with two other commonly applied residual-based tests: a Shewhart individuals chart and a Cumulative Sum (CUSUM) control chart.

  19. Variability in the quality of overdose advice in Summary of Product Characteristics (SPC) documents: gut decontamination recommendations for CNS drugs.

    Science.gov (United States)

    Wall, Andrew J B; Bateman, D N; Waring, W S

    2009-01-01

    Deliberate self-poisoning is a major cause of morbidity and mortality. The Summary of Product Characteristics (SPC) document is a legal requirement for all drugs, and Section 4.9 addresses the features of toxicity and clinical advice on management of overdose. The quality and appropriateness of this advice have received comparatively little attention. Section 4.9 of the SPC was examined for all drugs in the central nervous system (CNS) category of the British National Formulary. Advice concerning gut decontamination was examined with respect to specific interventions: induced vomiting, oral activated charcoal, gastric lavage, and other interventions. Data were compared with standard reference sources for clinical management advice in poisoning. These were graded 'A' if no important differences existed, 'B' if differences were noted but not thought clinically important, and 'C' if differences were thought to be clinically significant. SPC documents were examined for 258 medications from 67 manufacturers. The overall agreement was 'A' in 23 (8.9%), 'B' in 28 (10.9%) and 'C' in 207 (80.2%). Discrepancies were due to inappropriate recommendation of induced emesis in 21.7% (95% confidence interval 17.1, 27.1), gastric lavage in 38.4% (32.7, 44.4), other gut decontamination in 5.8% (3.6, 9.4) and failure to recommend oral activated charcoal in 57.4% (51.1, 63.4). Gut decontamination advice in SPC documents with respect to CNS drugs was inadequate. Possible reasons for the observed discrepancies and ways of improving the consistency of advice are proposed.

  20. Docetaxel Hidrat Menghambat Proliferasi dan Metastasis Sel Kanker Oral SP-C1 melalui Induksi Protein Maspin

    Directory of Open Access Journals (Sweden)

    Supriatno Supriatno

    2013-07-01

    Full Text Available Human oral tongue cancer (SP-C1 is thought to be a high grade malignancy. Despite advances in surgery, radiotherapy, chemotherapy and combination therapy, prognosis and survival of patients with human tongue cancer have not significantly improved over the past several decades. Treatment options for recurrent or refractory tongue cancer are limited. Therefore, as a strategy for refractory cancer, anti-mitotic chemotherapy and its mechanisms are of considerable interest, including those using docetaxel hydrate for inducing maspin protein. In the current study, the mechanisms responsible for growth suppression and metastasis of SP-C1 by docetaxel hydrate through induction of maspin regulation were investigated. To evaluate in vitro cell proliferation and cell metastasis, MTT and out-growth assays were performed, respectively. Furthermore, the expression of maspin mediated by docetaxel hydrate was analysed by Western blotting. The results showed that treatment with 50 g/ml docetaxel hydrate significantly suppressed SP-C1 cell growth from day 1. Strong inhibition of metastasis of SP-C1 cells was also shown by treatment with 50 g/ml of docetaxel hydrate. Moreover, a significant induction of maspin regulation was detected in cells treated with 10 and 50 g/ml of docetaxel hydrate. However, the same protein level was demonstrated in -tubulin expression. These findings suggest that docetaxel hydrate may have potential for powerful anti-mitotic chemotherapy through induction of maspin regulation.DOI: 10.14693/jdi.v15i1.77

  1. Modulation of Spc1 stress-activated protein kinase activity by methylglyoxal through inhibition of protein phosphatase in the fission yeast Schizosaccharomyces pombe

    International Nuclear Information System (INIS)

    Takatsume, Yoshifumi; Izawa, Shingo; Inoue, Yoshiharu

    2007-01-01

    Methylglyoxal, a ubiquitous metabolite derived from glycolysis has diverse physiological functions in yeast cells. Previously, we have reported that extracellularly added methylglyoxal activates Spc1, a stress-activated protein kinase (SAPK), in the fission yeast Schizosaccharomyces pombe [Y. Takatsume, S. Izawa, Y. Inoue, J. Biol. Chem. 281 (2006) 9086-9092]. Phosphorylation of Spc1 by treatment with methylglyoxal in S. pombe cells defective in glyoxalase I, an enzyme crucial for the metabolism of methylglyoxal, continues for a longer period than in wild-type cells. Here we show that methylglyoxal inhibits the activity of the protein phosphatase responsible for the dephosphorylation of Spc1 in vitro. In addition, we found that methylglyoxal inhibits human protein tyrosine phosphatase 1B (PTP1B) also. We propose a model for the regulation of the activity of the Spc1-SAPK signaling pathway by methylglyoxal in S. pombe

  2. Aplikasi Soft System Methodology dalam Analisis Diplomasi Angkatan Laut Indonesia melalui Pengiriman Satgas Maritim TNI Pada Misi UNIFIL MTF

    Directory of Open Access Journals (Sweden)

    Trio Sirmareza

    2017-05-01

    Full Text Available This article discusses Indonesia's participation in UNIFIL MTF, as a way for the country to exercise its naval diplomacy. Using Ken Booth's theory of naval diplomacy as analytical framework and employing the Soft System Methodology model, this article seeks to explain Indonesia's motives for joining UNIFIL MTF, namely the maintenance of the world peace as stipulated by the country's constitution and concomitantly, Indonesia's interest to enhance its global role as middle power. The application of naval diplomacy and Soft System Methodology in this article provides a theoretical and methodological-informed analysis in scrutinising Indonesia's participation in international peacekeeping operation. By doing so, this article attemps to fill the lacuna in the existing body of works which commonly neglect the theoretical basis and/or sound methodological framework in their observation and evaluation concerning the topic at hand. The article finds that Indonesian maritime task force in UNIFIL MTF has flexibility, mobility, projection ability and access potential to carry out Indonesia's diplomatic agenda. However, Indonesia still needs to consider improving the capacity of its maritime task force in order for it to function as maximum signifier for Indonesia's prestige and foreign policy commitment.

  3. Synthetic lung surfactants containing SP-B and SP-C peptides plus novel phospholipase-resistant lipids or glycerophospholipids

    Directory of Open Access Journals (Sweden)

    Robert H. Notter

    2016-10-01

    Full Text Available Background This study examines the biophysical and preclinical pulmonary activity of synthetic lung surfactants containing novel phospholipase-resistant phosphonolipids or synthetic glycerophospholipids combined with Super Mini-B (S-MB DATK and/or SP-Css ion-lock 1 peptides that replicate the functional biophysics of surfactant proteins (SP-B and SP-C. Phospholipase-resistant phosphonolipids used in synthetic surfactants are DEPN-8 and PG-1, molecular analogs of dipalmitoyl phosphatidylcholine (DPPC and palmitoyl-oleoyl phosphatidylglycerol (POPG, while glycerophospholipids used are active lipid components of native surfactant (DPPC:POPC:POPG 5:3:2 by weight. The objective of the work is to test whether these novel lipid/peptide synthetic surfactants have favorable preclinical activity (biophysical, pulmonary for therapeutic use in reversing surfactant deficiency or dysfunction in lung disease or injury. Methods Surface activity of synthetic lipid/peptide surfactants was assessed in vitro at 37 °C by measuring adsorption in a stirred subphase apparatus and dynamic surface tension lowering in pulsating and captive bubble surfactometers. Shear viscosity was measured as a function of shear rate on a Wells-Brookfield micro-viscometer. In vivo pulmonary activity was determined by measuring lung function (arterial oxygenation, dynamic lung compliance in ventilated rats and rabbits with surfactant deficiency/dysfunction induced by saline lavage to lower arterial PO2 to <100 mmHg, consistent with clinical acute respiratory distress syndrome (ARDS. Results Synthetic surfactants containing 5:3:2 DPPC:POPC:POPG or 9:1 DEPN-8:PG-1 combined with 3% (by wt of S-MB DATK, 3% SP-Css ion-lock 1, or 1.5% each of both peptides all adsorbed rapidly to low equilibrium surface tensions and also reduced surface tension to ≤1 mN/m under dynamic compression at 37 °C. However, dual-peptide surfactants containing 1.5% S-MB DATK + 1.5% SP-Css ion-lock 1 combined with

  4. The N-terminal segment of pulmonary surfactant lipopeptide SP-C has intrinsic propensity to interact with and perturb phospholipid bilayers

    DEFF Research Database (Denmark)

    Plasencia, Inés; Rivas, Luis; Keough, Kevin M W

    2004-01-01

    aggregation, and leakage of the aqueous content of the vesicles. The lipid-peptide interaction includes a significant hydrophobic component for both zwitterionic and anionic membranes, although the interaction with phosphatidylglycerol bilayers is also electrostatic in nature. The effects of the SP-C N......-terminal peptides on the membrane structure are mediated by significant perturbations of the packing order and mobility of phospholipid acyl chain segments deep in the bilayer, as detected by differential scanning calorimetry and spin-label ESR. These results suggest that the N-terminal region of SP-C, even...

  5. Effect of SP-C on surface potential distribution in pulmonary surfactant: Atomic force microscopy and Kelvin probe force microscopy study

    International Nuclear Information System (INIS)

    Hane, Francis; Moores, Brad; Amrein, Matthias; Leonenko, Zoya

    2009-01-01

    The air-lung interface is covered by a molecular film of pulmonary surfactant (PS). The major function of the film is to reduce the surface tension of the lung's air-liquid interface, providing stability to the alveolar structure and reducing the work of breathing. Earlier we have shown that function of bovine lipid extract surfactant (BLES) is related to the specific molecular architecture of surfactant films. Defined molecular arrangement of the lipids and proteins of the surfactant film also give rise to a local highly variable electrical surface potential of the interface. In this work we investigated a simple model of artificial lung surfactant consisting of DPPC, eggPG, and surfactant protein C (SP-C). Effects of surface compression and the presence of SP-C on the monolayer structure and surface potential distribution were investigated using atomic force microscopy (AFM) and Kelvin probe force microscopy (KPFM). We show that topography and locally variable surface potential of DPPC-eggPG lipid mixture are similar to those of pulmonary surfactant BLES in the presence of SP-C and differ in surface potential when SP-C is absent.

  6. Establishment of an experimental human lung adenocarcinoma cell line SPC-A-1BM with high bone metastases potency by 99mTc-MDP bone scintigraphy

    International Nuclear Information System (INIS)

    Yang Shunfang; Dong Qianggang; Yao Ming; Shi Meiping; Ye Jianding; Zhao Langxiang; Su Jianzhong; Gu Weiyong; Xie Wenhui; Wang Kankan; Du Yanzhi; Li Yao; Huang Yan

    2009-01-01

    Background: Bone metastasis is one of the most common clinical phenomena of late stage lung cancer. A major impediment to understanding the pathogenesis of bone metastasis has been the lack of an appropriate animal and cell model. This study aims to establish human lung adenocarcinoma cell line with highly bone metastases potency with 99m Tc-MDP bone scintigraphy. Methods: The human lung adenocarcinoma cancer cells SPC-A-1 were injected into the left cardiac ventricle of NIH-Beige-Nude-XID (NIH-BNX) immunodeficient mice. The metastatic lesions of tumor-bearing mice were imaged with 99m Tc-MDP bone scintigraphy on a Siemens multi-single photon emission computed tomography. Pinhole images were acquired on a GZ-B conventional gamma camera with a self-designed pinhole collimator. The mice with bone metastasis were sacrificed under deep anesthesia, and the lesions were resected. Bone metastatic cancer cells in the resected lesions were subjected for culture and then reinoculated into the NIH-BNX mice through left cardiac ventricle. The process was repeated for eight cycles to obtain a novel cell subline SPC-A-1BM. Real-time polymerase chain reaction (PCR) was used to compare the gene expression differences in the parental and SPC-A-1BM cells. Results: The bone metastasis sites were successfully revealed by bone scintigraphy. The established bone metastasis cell line SPC-A-1BM had a high potential to metastasize in bone, including mandible, humerus, thoracic vertebra, lumbar, femur, patella, ilium and cartilage rib. The expression level of vascular endothelial growth factor gene family, Bcl-2 and cell adhesion-related genes ECM1, ESM1, AF1Q, SERPINE2 and FN1 were examined. Gene expression difference was found between parental and bone-seeking metastasis cell SPC-A-1BM, which indicates SPC-A-1BM has metastatic capacity vs. its parental cells. Conclusion: SPC-A-1BM is a bone-seeking metastasis human lung adenocarcinoma cell line. Bone scintigraphy may be used as an

  7. Mtf-1 lymphoma-susceptibility locus affects retention of large thymocytes with high ROS levels in mice after γ-irradiation

    International Nuclear Information System (INIS)

    Maruyama, Masaki; Yamamoto, Takashi; Kohara, Yuki; Katsuragi, Yoshinori; Mishima, Yukio; Aoyagi, Yutaka; Kominami, Ryo

    2007-01-01

    Mouse strains exhibit different susceptibilities to γ-ray-induced thymic lymphomas. Our previous study identified Mtf-1 (metal responsive transcription factor-1) as a candidate susceptibility gene, which is involved in the radiation-induced signaling pathway that regulates the cellular reactive oxygen species (ROS). To reveal the mechanism for the increased susceptibility conferred by Mtf-1 locus, we examined early effects of γ-ray on ROS levels in vivo and its difference between Mtf-1 susceptible and resistant congenic mice. Here, we show the detection of clonally growing thymocytes at 4 weeks after irradiation, indicating the start of clonal expansion at a very early stage. We also show that large thymocytes with higher ROS levels and a proliferation capacity were more numerous in the Mtf-1 susceptible mice than the resistant mice when examined at 7 days after irradiation, although such tendency was not found in mice lacking one allele of Bcl11b tumor suppressor gene. This high retention of the large thymocytes, at a high risk for ROS-induced mutation, is a compensatory proliferation and regeneration response to depletion of the thymocytes after irradiation and the response is likely to augment the development of prelymphoma cells leading to thymic lymphomas

  8. Theory of lidar method for measurement of the modulation transfer function of water layers.

    Science.gov (United States)

    Dolin, Lev S

    2013-01-10

    We develop a method to evaluate the modulation transfer function (MTF) of a water layer from the characteristics of lidar signal backscattered by water volume. We propose several designs of a lidar system for remote measurement of the MTF and the procedure to determine optical properties of water using the measured MTF. We discuss a laser system for sea-bottom imaging that accounts for the influence of water slab on the image structure and allows for correction of image distortions caused by light scattering in water. © 2013 Optical Society of America

  9. Measurements of ocean wave spectra and modulation transfer function with the airborne two-frequency scatterometer

    Science.gov (United States)

    Weissman, D. E.; Johnson, J. W.

    1986-01-01

    The directional spectrum and the microwave modulation transfer function of ocean waves can be measured with the airborne two frequency scatterometer technique. Similar to tower based observations, the aircraft measurements of the Modulation Transfer Function (MTF) show that it is strongly affected by both wind speed and sea state. Also detected are small differences in the magnitudes of the MTF between downwind and upwind radar look directions, and variations with ocean wavenumber. The MTF inferred from the two frequency radar is larger than that measured using single frequency, wave orbital velocity techniques such as tower based radars or ROWS measurements from low altitude aircraft. Possible reasons for this are discussed. The ability to measure the ocean directional spectrum with the two frequency scatterometer, with supporting MTF data, is demonstrated.

  10. Measurements of ocean wave spectra and modulation transfer function with the airborne two frequency scatterometer

    Science.gov (United States)

    Weissman, D. E.; Johnson, J. W.

    1984-01-01

    The directional spectrum and the microwave modulation transfer function of ocean waves can be measured with the airborne two frequency scatterometer technique. Similar to tower based observations, the aircraft measurements of the Modulation Transfer Function (MTF) show that it is strongly affected by both wind speed and sea state. Also detected are small differences in the magnitudes of the MTF between downwind and upwind radar look directions, and variations with ocean wavenumber. The MTF inferred from the two frequency radar is larger than that measured using single frequency, wave orbital velocity techniques such as tower based radars or ROWS measurements from low altitude aircraft. Possible reasons for this are discussed. The ability to measure the ocean directional spectrum with the two frequency scatterometer, with supporting MTF data, is demonstrated.

  11. The expression of HoxB5 and SPC in neonatal rat lung after exposure to fluoxetine.

    Science.gov (United States)

    Taghizadeh, Razieh; Taghipour, Zahra; Karimi, Akbar; Shamsizadeh, Ali; Taghavi, Mohammad Mohsen; Shariati, Mahdi; Shabanizadeh, Ahmad; Jafari Naveh, Hamid Reza; Bidaki, Reza; Aminzadeh, Fariba

    2016-01-01

    Approximately 10% of pregnant women suffer from pregnancy-associated depression. Fluoxetine, as a selective serotonin reuptake inhibitor, is being employed as a therapy for depressive disorders. The present study aimed to determine the effects of fluoxetine on neonatal lung development. Thirty pregnant Wistar rats (weighing 200-250 g) were treated daily with 7 mg/kg fluoxetine from gestation day 0 to gestation day 21, via gavage. The control group received a similar volume of distilled water only. Following delivery, the newborns and their lungs were immediately weighed in both of the groups. The right lung was fixed for histological assessments while the left lung was used for evaluation of the expression of SPC and HoxB5 by the real-time polymerase chain reaction method. Results have indicated that even though the body weight and the number of neonatal rats in both groups were the same, the lung weight of neonates exposed to fluoxetine was significantly different compared to the control group ( P fluoxetine treatment group morphologically appears to be similar to the pseudoglandular phase, whereas the control group lungs experienced more development. According to the upregulated expression of HoxB5 concerning histological findings, results of the present study showed that fluoxetine can influence lung growth and may in turn lead to delay in lung development. So establishment of studies to identify the effects of antidepressant drugs during pregnancy is deserved.

  12. Dumpy-30 family members as determinants of male fertility and interaction partners of metal-responsive transcription factor 1 (MTF-1 in Drosophila

    Directory of Open Access Journals (Sweden)

    Renkawitz-Pohl Renate

    2008-06-01

    Full Text Available Abstract Background Metal-responsive transcription factor 1 (MTF-1, which binds to metal response elements (MREs, plays a central role in transition metal detoxification and homeostasis. A Drosophila interactome analysis revealed two candidate dMTF-1 interactors, both of which are related to the small regulatory protein Dumpy-30 (Dpy-30 of the worm C. elegans. Dpy-30 is the founding member of a protein family involved in chromatin modifications, notably histone methylation. Mutants affect mating type in yeast and male mating in C. elegans. Results Constitutive expression of the stronger interactor, Dpy-30L1 (CG6444, in transgenic flies inhibits MTF-1 activity and results in elevated sensitivity to Cd(II and Zn(II, an effect that could be rescued by co-overexpression of dMTF-1. Electrophoretic mobility shift assays (EMSA suggest that Dpy-30L1 interferes with the binding of MTF-1 to its cognate MRE binding site. Dpy-30L1 is expressed in the larval brain, gonads, imaginal discs, salivary glands and in the brain, testes, ovaries and salivary glands of adult flies. Expression of the second interactor, Dpy-30L2 (CG11591, is restricted to larval male gonads, and to the testes of adult males. Consistent with these findings, dpy-30-like transcripts are also prominently expressed in mouse testes. Targeted gene disruption by homologous recombination revealed that dpy-30L1 knockout flies are viable and show no overt disruption of metal homeostasis. In contrast, the knockout of the male-specific dpy-30L2 gene results in male sterility, as does the double knockout of dpy-30L1 and dpy-30L2. A closer inspection showed that Dpy-30L2 is expressed in elongated spermatids but not in early or mature sperm. Mutant sperm had impaired motility and failed to accumulate in sperm storage organs of females. Conclusion Our studies help to elucidate the physiological roles of the Dumpy-30 proteins, which are conserved from yeast to humans and typically act in concert with

  13. Pacific Reef Assessment and Monitoring Program: Rapid Ecological Assessments of Fish Large-Area Stationary Point Count Surveys (SPC) in the Pacific Ocean from 2000-09-09 to 2007-06-08 (NCEI Accession 0162466)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The large-area stationary point count (SPC) method is used to conduct reef fish surveys in the Hawaiian and Mariana Archipelagos, American Samoa, and the Pacific...

  14. Pacific Reef Assessment and Monitoring Program: Rapid Ecological Assessments of Fish Large-Area Stationary Point Count Surveys (SPC) at Coral Reef Sites across the Pacific Ocean from 2000 to 2007

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The large-area stationary point count (SPC) method is used to conduct reef fish surveys in the Hawaiian and Mariana Archipelagos, American Samoa, and the Pacific...

  15. Addressing challenges of modulation transfer function measurement with fisheye lens cameras

    Science.gov (United States)

    Deegan, Brian M.; Denny, Patrick E.; Zlokolica, Vladimir; Dever, Barry; Russell, Laura

    2015-03-01

    Modulation transfer function (MTF) is a well defined and accepted method of measuring image sharpness. The slanted edge test, as defined in ISO12233 is a standard method of calculating MTF, and is widely used for lens alignment and auto-focus algorithm verification. However, there are a number of challenges which should be considered when measuring MTF in cameras with fisheye lenses. Due to trade-offs related Petzval curvature, planarity of the optical plane is difficult to achieve in fisheye lenses. It is therefore critical to have the ability to accurately measure sharpness throughout the entire image, particularly for lens alignment. One challenge for fisheye lenses is that, because of the radial distortion, the slanted edges will have different angles, depending on the location within the image and on the distortion profile of the lens. Previous work in the literature indicates that MTF measurements are robust for angles between 2 and 10 degrees. Outside of this range, MTF measurements become unreliable. Also, the slanted edge itself will be curved by the lens distortion, causing further measurement problems. This study summarises the difficulties in the use of MTF for sharpness measurement in fisheye lens cameras, and proposes mitigations and alternative methods.

  16. Evaluating Statistical Process Control (SPC) techniques and computing the uncertainty of force calibrations

    Science.gov (United States)

    Navard, Sharon E.

    1989-01-01

    In recent years there has been a push within NASA to use statistical techniques to improve the quality of production. Two areas where statistics are used are in establishing product and process quality control of flight hardware and in evaluating the uncertainty of calibration of instruments. The Flight Systems Quality Engineering branch is responsible for developing and assuring the quality of all flight hardware; the statistical process control methods employed are reviewed and evaluated. The Measurement Standards and Calibration Laboratory performs the calibration of all instruments used on-site at JSC as well as those used by all off-site contractors. These calibrations must be performed in such a way as to be traceable to national standards maintained by the National Institute of Standards and Technology, and they must meet a four-to-one ratio of the instrument specifications to calibrating standard uncertainty. In some instances this ratio is not met, and in these cases it is desirable to compute the exact uncertainty of the calibration and determine ways of reducing it. A particular example where this problem is encountered is with a machine which does automatic calibrations of force. The process of force calibration using the United Force Machine is described in detail. The sources of error are identified and quantified when possible. Suggestions for improvement are made.

  17. Application of statistical methods (SPC) for an optimized control of the irradiation process of high-power semiconductors

    International Nuclear Information System (INIS)

    Mittendorfer, J.; Zwanziger, P.

    2000-01-01

    High-power bipolar semiconductor devices (thyristors and diodes) in a disc-type shape are key components (semiconductor switches) for high-power electronic systems. These systems are important for the economic design of energy transmission systems, i.e. high-power drive systems, static compensation and high-voltage DC transmission lines. In their factory located in Pretzfeld, Germany, the company, eupec GmbH+Co.KG (eupec), is producing disc-type devices with ceramic encapsulation in the high-end range for the world market. These elements have to fulfill special customer requirements and therefore deliver tailor-made trade-offs between their on-state voltage and dynamic switching behaviour. This task can be achieved by applying a dedicated electron irradiation on the semiconductor pellets, which tunes this trade-off. In this paper, the requirements to the irradiation company Mediscan GmbH, from the point of view of the semiconductor manufacturer, are described. The actual strategy for controlling the irradiation results to fulfill these requirements are presented, together with the choice of relevant parameters from the viewpoint of the irradiation company. The set of process parameters monitored, using statistical process control (SPC) techniques, includes beam current and energy, conveyor speed and irradiation geometry. The results are highlighted and show the successful co-operation in this business. Watching this process vice versa, an idea is presented and discussed to develop the possibilities of a highly sensitive dose detection device by using modified diodes, which could function as accurate yet cheap and easy-to-use detectors as routine dosimeters for irradiation institutes. (author)

  18. DISPERSIT SPC 1000™

    Science.gov (United States)

    Technical product bulletin: aka SEACARE, ECOSPERSE, this water based dispersant may be applied in oil spill cleanups by aerial or boat spraying. Concentration/application rates depend on type of oil, degree of weathering, temperature, extent of slick.

  19. PENGURANGAN DEFECT PADA PRODUK SEPATU DENGAN MENGINTEGRASIKAN STATISTICAL PROCESS CONTROL (SPC DAN ROOT CAUSE ANALYSIS (RCA STUDI KASUS PT. XYZ

    Directory of Open Access Journals (Sweden)

    Moch. Teguh Fajrin

    2018-04-01

    Full Text Available PT. XYZ is a foreign capital investment companies are located in one area of town of Sidoarjo which has more than 7000 employees in it and of course want to have a high quality product . PT footwear products. XYZ is the world quality products that promote the quality and comfort of the wearer. Problems that occur in the production process of PT . XYZ of 7 -injection engine that has the most number of engine defect is 5.6 and 7. Quality products at heavily influence the shoe production to consumers. If damaged, then the product can not be distributed to consumers .Therefore , the quality of the shoes must be maintained for the successful marketing of the product. From our previous improvements made in reducing the defect in the production process , but the result is less than optimal , so do research that aims to make improvements again with another method . The method used in this research is to apply the methods of Statistical Processing Control (SPC and Root Cause Analysis (RCA. The results of the check sheet analysis and Pareto diagram can be seen the frequency of product defects (defects over roughing most occurred in March 2016 as many as 345 shoes (62% of the total production of 489 products. Then the second frequency in February 2016 as many as 214 shoes (38% of the total production of 357 products. And from the image Control Chart P can be concluded that the data are in a state of uncontrolled. Because of all these 50 data, there is one data point that is outside the control limits (out of control, on the 4th point the data has a value of the proportion of 1, beyond the limits Upper Control Limit (UCL is equal to 0.938. During the dots located within the boundaries of a controller, a process is under controlled conditions, and no action required. However, one point that lies outside the control limit is interpreted as the fact that the quality control in the production process (injection PT. XYZ uncontrolled or still experiencing

  20. Security camera resolution measurements: Horizontal TV lines versus modulation transfer function measurements.

    Energy Technology Data Exchange (ETDEWEB)

    Birch, Gabriel Carisle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Griffin, John Clark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    The horizontal television lines (HTVL) metric has been the primary quantity used by division 6000 related to camera resolution for high consequence security systems. This document shows HTVL measurements are fundamen- tally insufficient as a metric to determine camera resolution, and propose a quantitative, standards based methodology by measuring the camera system modulation transfer function (MTF), the most common and accepted metric of res- olution in the optical science community. Because HTVL calculations are easily misinterpreted or poorly defined, we present several scenarios in which HTVL is frequently reported, and discuss their problems. The MTF metric is discussed, and scenarios are presented with calculations showing the application of such a metric.

  1. Live-cell topology assessment of URG7, MRP6102 and SP-C using glycosylatable green fluorescent protein in mammalian cells

    International Nuclear Information System (INIS)

    Lee, Hunsang; Lara, Patricia; Ostuni, Angela; Presto, Jenny; Johansson, Janne; Nilsson, IngMarie; Kim, Hyun

    2014-01-01

    Highlights: • Glycosylatable GFP (gGFP) is developed for the use in mammalian cells. • gGFP selectively loses its fluorescence upon N-linked glycosylation in the ER lumen. • Differential fluorescence/glycosylation pattern probes membrane protein topology. • Membrane topology of URG7, MRP6 102 , and SP-C was determined by gGFP tagging in vivo. - Abstract: Experimental tools to determine membrane topology of a protein are rather limited in higher eukaryotic organisms. Here, we report the use of glycosylatable GFP (gGFP) as a sensitive and versatile membrane topology reporter in mammalian cells. gGFP selectively loses its fluorescence upon N-linked glycosylation in the ER lumen. Thus, positive fluorescence signal assigns location of gGFP to the cytosol whereas no fluorescence signal and a glycosylated status of gGFP map the location of gGFP to the ER lumen. By using mammalian gGFP, the membrane topology of disease-associated membrane proteins, URG7, MRP6 102 , SP-C(Val) and SP-C(Leu) was confirmed. URG7 is partially targeted to the ER, and inserted in C in form. MRP6 102 and SP-C(Leu/Val) are inserted into the membrane in C out form. A minor population of untargeted SP-C is removed by proteasome dependent quality control system

  2. Live-cell topology assessment of URG7, MRP6{sub 102} and SP-C using glycosylatable green fluorescent protein in mammalian cells

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hunsang [School of Biological Sciences, Seoul National University, Seoul 151-747 (Korea, Republic of); Lara, Patricia [Center for Biomembrane Research, Department of Biochemistry and Biophysics, Stockholm University, SE-106 91 Stockholm (Sweden); Ostuni, Angela [Department of Sciences, University of Basilicata, Viale dell’Ateneo Lucano 10, 85100 Potenza (Italy); Presto, Jenny [Karolinska Institutet, Dept of Neurobiology, Care Sciences and Society, Novum 5th Floor, 141 86 Stockholm (Sweden); Johansson, Janne [Karolinska Institutet, Dept of Neurobiology, Care Sciences and Society, Novum 5th Floor, 141 86 Stockholm (Sweden); Department of Anatomy, Physiology and Biochemistry, Swedish University of Agricultural Sciences, The Biomedical Centre, 751 23 Uppsala (Sweden); Institute of Mathematics and Natural Sciences, Tallinn University, Narva mnt 25, 101 20 Tallinn (Estonia); Nilsson, IngMarie [Center for Biomembrane Research, Department of Biochemistry and Biophysics, Stockholm University, SE-106 91 Stockholm (Sweden); Kim, Hyun, E-mail: joy@snu.ac.kr [School of Biological Sciences, Seoul National University, Seoul 151-747 (Korea, Republic of)

    2014-08-08

    Highlights: • Glycosylatable GFP (gGFP) is developed for the use in mammalian cells. • gGFP selectively loses its fluorescence upon N-linked glycosylation in the ER lumen. • Differential fluorescence/glycosylation pattern probes membrane protein topology. • Membrane topology of URG7, MRP6{sub 102}, and SP-C was determined by gGFP tagging in vivo. - Abstract: Experimental tools to determine membrane topology of a protein are rather limited in higher eukaryotic organisms. Here, we report the use of glycosylatable GFP (gGFP) as a sensitive and versatile membrane topology reporter in mammalian cells. gGFP selectively loses its fluorescence upon N-linked glycosylation in the ER lumen. Thus, positive fluorescence signal assigns location of gGFP to the cytosol whereas no fluorescence signal and a glycosylated status of gGFP map the location of gGFP to the ER lumen. By using mammalian gGFP, the membrane topology of disease-associated membrane proteins, URG7, MRP6{sub 102}, SP-C(Val) and SP-C(Leu) was confirmed. URG7 is partially targeted to the ER, and inserted in C{sub in} form. MRP6{sub 102} and SP-C(Leu/Val) are inserted into the membrane in C{sub out} form. A minor population of untargeted SP-C is removed by proteasome dependent quality control system.

  3. Spatial distribution measured by the modulation transfer function

    International Nuclear Information System (INIS)

    Rossi, P.; Brice, D.K.; Doyle, B.L.

    2003-01-01

    Spatial distributions in ion micro-beam and IBA experimental practice are regularly characterized through the parameters of FWHM and tail area percentage (TF, tail fraction). Linear and stationary transducer theory allows these distributions to be described in the Fourier-dual frequency space, and provides an indirect method to evaluate them through measurement of the modulation transfer function (MTF). We suggest direct measurement of MTF by employing bar pattern grids, similar to those used for calibration of radiological equipment. Assuming spatial distributions of the form exp(-(|αx|) η ), we are able to relate the MTF measurements to the more popular FWHM and TF. This new approach to determine spatial resolution can become a standard for use by the micro-beam community

  4. Changes in the bacterial number (enterohaemorrhagic E. coli O157:H7, coliforms and SPC) in salted vegetables during storage and by treatment with electron-beam irradiation

    International Nuclear Information System (INIS)

    Miyahara, Michiko; Miyahara, Makoto

    2007-01-01

    Enterohaemorrhagic Escherichia coli O157:H7 causes severe illness in humans, especially young children and elder people. Some 2-3% salted vegetables (called Asazuke) contaminated with E. coli O157:H7 have caused food-poisoning and even death. The viability of E. coli O157:H7 in saline water and in salted vegetables was tested. During cold and frozen storage, the apparent decrease in the number of E. coli O157:H7 was not observed. However, electron-beam irradiation (0.534, 1.097 and 2.639 kGy) caused clear decrease in the numbers of E. coli O157:H7 in frozen salted Mizuna. The number of standard plating count (SPC) and coliforms were also counted and compared with the changes in the number of E. coli O157:H7. (author)

  5. Contrast computation methods for interferometric measurement of sensor modulation transfer function

    Science.gov (United States)

    Battula, Tharun; Georgiev, Todor; Gille, Jennifer; Goma, Sergio

    2018-01-01

    Accurate measurement of image-sensor frequency response over a wide range of spatial frequencies is very important for analyzing pixel array characteristics, such as modulation transfer function (MTF), crosstalk, and active pixel shape. Such analysis is especially significant in computational photography for the purposes of deconvolution, multi-image superresolution, and improved light-field capture. We use a lensless interferometric setup that produces high-quality fringes for measuring MTF over a wide range of frequencies (here, 37 to 434 line pairs per mm). We discuss the theoretical framework, involving Michelson and Fourier contrast measurement of the MTF, addressing phase alignment problems using a moiré pattern. We solidify the definition of Fourier contrast mathematically and compare it to Michelson contrast. Our interferometric measurement method shows high detail in the MTF, especially at high frequencies (above Nyquist frequency). We are able to estimate active pixel size and pixel pitch from measurements. We compare both simulation and experimental MTF results to a lens-free slanted-edge implementation using commercial software.

  6. Error of the slanted edge method for measuring the modulation transfer function of imaging systems.

    Science.gov (United States)

    Xie, Xufen; Fan, Hongda; Wang, Hongyuan; Wang, Zebin; Zou, Nianyu

    2018-03-01

    The slanted edge method is a basic approach for measuring the modulation transfer function (MTF) of imaging systems; however, its measurement accuracy is limited in practice. Theoretical analysis of the slanted edge MTF measurement method performed in this paper reveals that inappropriate edge angles and random noise reduce this accuracy. The error caused by edge angles is analyzed using sampling and reconstruction theory. Furthermore, an error model combining noise and edge angles is proposed. We verify the analyses and model with respect to (i) the edge angle, (ii) a statistical analysis of the measurement error, (iii) the full width at half-maximum of a point spread function, and (iv) the error model. The experimental results verify the theoretical findings. This research can be referential for applications of the slanted edge MTF measurement method.

  7. Measurement of the presampled two-dimensional modulation transfer function of digital imaging systems

    International Nuclear Information System (INIS)

    Fetterly, Kenneth A.; Hangiandreou, Nicholas J.; Schueler, Beth A.; Ritenour, E. Russell

    2002-01-01

    The purpose of this work was to develop methods to measure the presampled two-dimensional modulation transfer function (2D MTF) of digital imaging systems. A custom x-ray 'point source' phantom was created by machining 256 holes with diameter 0.107 mm through a 0.5-mm-thick copper plate. The phantom was imaged several times, resulting in many images of individual x-ray 'spots'. The center of each spot (with respect to the pixel matrix) was determined to subpixel accuracy by fitting each spot to a 2D Gaussian function. The subpixel spot center locations were used to create a 5x oversampled system point spread function (PSF), which characterizes the optical and electrical properties of the system and is independent of the pixel sampling of the original image. The modulus of the Fourier transform of the PSF was calculated. Next, the Fourier function was normalized to the zero frequency value. Finally, the Fourier transform function was divided by the first-order Bessel function that defined the frequency content of the holes, resulting in the presampled 2D MTF. The presampled 2D MTF of a 0.1 mm pixel pitch computed radiography system and 0.2 mm pixel pitch flat panel digital imaging system that utilized a cesium iodide scintillator was measured. Comparison of the axial components of the 2D MTF to one-dimensional MTF measurements acquired using an edge device method demonstrated that the two methods produced consistent results

  8. Image quality of the cat eye measured during retinal ganglion cell experiments.

    Science.gov (United States)

    Bonds, A B; Enroth-Cugell, C; Pinto, L H

    1972-01-01

    1. The modulation transfer function (MTF) of the dioptrics of fifteen cat eyes was determined. The aerial image, formed by the eye of a standard object (a 0.5-1.0 degrees annulus), was photographed. The transmission of the film negative was measured with a scanning microdensitometer to yield the light distribution within the aerial image. Correcting for the double passage, this experimentally determined light distribution and the known object light distribution were used to obtain the MTF, applying Fourier methods. Each MTF was used to calculate the light distribution within the retinal image of stimuli of various geometry used in experiments on retinal ganglion cells in the same eye.2. When the eye was equipped with an artificial pupil of the same size as that used in the neurophysiological experiments (4.0-4.8 mm diam.) the MTF had fallen to 0.5 at 2.43 c/deg. When the pupil was removed the MTF had fallen to 0.5 at a much lower spatial frequency (1.0 c/deg). This shows that even when one uses an artificial pupil too large to provide optimal image quality there is a vast improvement over using no pupil.3. These image quality measurements were prompted by the need to know the actual stimulus image in experiments on the functional organization of the receptive field, a need exemplified in this paper by a few specific physiological results. The full neurophysiological results appear in the next two papers.

  9. Nondestructive fission gas release measurement and analysis

    International Nuclear Information System (INIS)

    O'Leary, P.M.; Packard, D.R.

    1993-01-01

    Siemens Power Corporation (SPC) has performed reactor poolside gamma scanning measurements of fuel rods for fission gas release (FGR) detection for more than 10 yr. The measurement system has been previously described. Over the years, the data acquisition system, the method of spectrum analysis, and the means of reducing spectrum interference have been significantly improved. A personal computer (PC)-based multichannel analyzer (MCA) package is used to collect, display, and store high-resolution gamma-ray spectra measured in the fuel rod plenum. A PC spread sheet is used to fit the measured spectra and compute sample count rates after Compton background subtraction. A Zircaloy plenum spacer is often used to reduce positron annihilation interference that can arise from the INCONEL reg-sign plenum spring used in SPC-manufactured fuel rods

  10. Microbial diversity of mangrove sediment in Shenzhen Bay and gene cloning, characterization of an isolated phytase-producing strain of SPC09 B. cereus.

    Science.gov (United States)

    Zhang, Shengpeng; Liao, Shao-An; Yu, Xiaoyuan; Lu, Hongwu; Xian, Jian-An; Guo, Hui; Wang, Anli; Xie, Jian

    2015-06-01

    Phytases hydrolyze phytate to release inorganic phosphate, which decreases the requirement for phosphorus in fertilizers for crops and thus reduces environmental pollutants. This study analyzed microbial communities in rhizosphere sediment, collected in September 2012 from Shenzhen Bay, Guangdong, China, using high-throughput pyrosequencing; the results showed that the dominant taxonomic phyla were Chloroflexi, Firmicutes, and Proteobacteria, and the proportion of the beneficial bacteria, Bacillus, was 4.95 %. Twenty-nine culturable, phytase-producing bacteria were isolated, their phosphorus solubilization capacity was analyzed, and they were taxonomically characterized. Their phylogenetic placement was determined using 16S ribosomal RNA (rRNA) gene sequence analysis. The result shows that most of the isolates are members of the order Bacillales, although seven strains of Enterobacteriales, two strains of Pseudomonadales, and one strain of Oceanospirillales were also identified. The phytase gene was cloned from SPC09, Bacillus cereus, which showed the highest phosphorus solubilizing ability among the isolated strains. The gene encoded a primary translation product of 335 amino acids. A construct including the 1005-nt ORF fragment, Bc-phy, was transformed into Escherichia coli. The recombinant phytase was produced and purified, which revealed the temperature optima at 60 °C and pH optima at 6.5. The assessment by quantitative PCR (qPCR) showed an abundance of bacteria containing the Bc-phy gene; the level was generally higher in the mangrove forest than in the tidal flats and in surface soil compared to bottom soil, and the highest value was obtained in June. Herein, we report on the cloning, characterization, and activity of a novel phytase isolated from a mangrove system.

  11. Poster — Thur Eve — 01: The effect of the number of projections on MTF and CNR in Compton scatter tomography

    International Nuclear Information System (INIS)

    Chighvinadze, T; Pistorius, S

    2014-01-01

    Purpose: To investigate the dependence of the reconstructed image quality on the number of projections in multi-projection Compton scatter tomography (MPCST). The conventional relationship between the projection number used for reconstruction and reconstructed image quality pertained to CT does not necessarily apply to MPCST, which can produce images from a single projection if the detectors have sufficiently high energy and spatial resolution. Methods: The electron density image was obtained using filtered-backprojection of the scatter signal over circular arcs formed using Compton equation. The behavior of the reconstructed image quality as a function of the projection number was evaluated through analytical simulations and characterized by CNR and MTF. Results: The increase of the projection number improves the contrast with this dependence being a function of fluence. The number of projections required to approach the asymptotic maximum contrast decreases as the fluence increases. Increasing projection number increases the CNR but not spatial resolution. Conclusions: For MPCST using a 500eV energy resolution and a 2×2mm 2 size detector, an adequate image quality can be obtained with a small number of projections provided the incident fluence is high enough. This is conceptually different from conventional CT where a minimum number of projections is required to obtain an adequate image quality. While increasing projection number, even for the lowest dose value, the CNR increases even though the number of photons per projection decreases. The spatial resolution of the image is improved by increasing the sampling within a projection rather than by increasing the number of projections

  12. Measurement of the modulation transfer function of a charge-coupled device array by the combination of the self-imaging effect and slanted edge method.

    Science.gov (United States)

    Najafi, Sedigheh; Madanipour, Khosro

    2013-07-01

    In this paper, by a combination of the self-imaging effect for Ronchi gratings and the standard slanted edge modulation transfer function (MTF) measurement method for CCD cameras, the MTF of the CCD array without optics is measured. For this purpose, a Ronchi-type grating is illuminated by an expanded He-Ne laser. A self-image of the grating appears without optics on the CCD array that is located on the Talbot distance. The lines of the self-image of the grating are used as a slanted edge array. This method has all the advantages of the slanted edge method, and also since the array of the edge is ready, the total area of the CCD can be tested. The measured MTF is related to the CCD array without optics.

  13. Determination of modulation transfer function of a printer by measuring the autocorrelation of the transmission function of a printed Ronchi grating

    International Nuclear Information System (INIS)

    Madanipour, Khosro; Tavassoly, Mohammad T.

    2009-01-01

    We show theoretically and verify experimentally that the modulation transfer function (MTF) of a printing system can be determined by measuring the autocorrelation of a printed Ronchi grating. In practice, two similar Ronchi gratings are printed on two transparencies and the transparencies are superimposed with parallel grating lines. Then, the gratings are uniformly illuminated and the transmitted light from a large section is measured versus the displacement of one grating with respect to the other in a grating pitch interval. This measurement provides the required autocorrelation function for determination of the MTF

  14. Linear chirped slope profile for spatial calibration in slope measuring deflectometry

    Energy Technology Data Exchange (ETDEWEB)

    Siewert, F., E-mail: frank.siewert@helmholtz-berlin.de; Zeschke, T. [Helmholtz Zentrum Berlin für Materialien und Energie, Institut für Nanometer Optik und Technologie, Albert-Einstein-Str. 15, 12489 Berlin (Germany); Arnold, T.; Paetzelt, H. [Leibnitz Institut für Oberflächen Modifizierung Leipzig e.V., IOM, Permoserstr. 15, 04318 Leipzig (Germany); Yashchuk, V. V. [Lawerence Berkeley National Laboratory, Advanced Light Source, 1 Cyclotron Road, Berkeley, California 94720 (United States)

    2016-05-15

    Slope measuring deflectometry is commonly used by the X-ray optics community to measure the long-spatial-wavelength surface figure error of optical components dedicated to guide and focus X-rays under grazing incidence condition at synchrotron and free electron laser beamlines. The best performing instruments of this kind are capable of absolute accuracy on the level of 30-50 nrad. However, the exact bandwidth of the measurements, determined at the higher spatial frequencies by the instrument’s spatial resolution, or more generally by the instrument’s modulation transfer function (MTF) is hard to determine. An MTF calibration method based on application of a test surface with a one-dimensional (1D) chirped height profile of constant amplitude was suggested in the past. In this work, we propose a new approach to designing the test surfaces with a 2D-chirped topography, specially optimized for MTF characterization of slope measuring instruments. The design of the developed MTF test samples based on the proposed linear chirped slope profiles (LCSPs) is free of the major drawback of the 1D chirped height profiles, where in the slope domain, the amplitude strongly increases with the local spatial frequency of the profile. We provide the details of fabrication of the LCSP samples. The results of first application of the developed test samples to measure the spatial resolution of the BESSY-NOM at different experimental arrangements are also presented and discussed.

  15. Rapid objective measurement of gamma camera resolution using statistical moments.

    Science.gov (United States)

    Hander, T A; Lancaster, J L; Kopp, D T; Lasher, J C; Blumhardt, R; Fox, P T

    1997-02-01

    An easy and rapid method for the measurement of the intrinsic spatial resolution of a gamma camera was developed. The measurement is based on the first and second statistical moments of regions of interest (ROIs) applied to bar phantom images. This leads to an estimate of the modulation transfer function (MTF) and the full-width-at-half-maximum (FWHM) of a line spread function (LSF). Bar phantom images were acquired using four large field-of-view (LFOV) gamma cameras (Scintronix, Picker, Searle, Siemens). The following factors important for routine measurements of gamma camera resolution with this method were tested: ROI placement and shape, phantom orientation, spatial sampling, and procedural consistency. A 0.2% coefficient of variation (CV) between repeat measurements of MTF was observed for a circular ROI. The CVs of less than 2% were observed for measured MTF values for bar orientations ranging from -10 degrees to +10 degrees with respect to the x and y axes of the camera acquisition matrix. A 256 x 256 matrix (1.6 mm pixel spacing) was judged sufficient for routine measurements, giving an estimate of the FWHM to within 0.1 mm of manufacturer-specified values (3% difference). Under simulated clinical conditions, the variation in measurements attributable to procedural effects yielded a CV of less than 2% in newer generation cameras. The moments method for determining MTF correlated well with a peak-valley method, with an average difference of 0.03 across the range of spatial frequencies tested (0.11-0.17 line pairs/mm, corresponding to 4.5-3.0 mm bars). When compared with the NEMA method for measuring intrinsic spatial resolution, the moments method was found to be within 4% of the expected FWHM.

  16. Secondary structure and lipid interactions of the N-terminal segment of pulmonary surfactant SP-C in Langmuir films: IR reflection-absorption spectroscopy and surface pressure studies

    DEFF Research Database (Denmark)

    Bi, Xiaohong; Flach, Carol R; Pérez-Gil, Jesus

    2002-01-01

    reversibly with surface pressure (pi), suggestive of the peptide being squeezed out from hydrophobic regions of the monolayer. No such effect was observed for DPPG/peptide monolayers, indicative of stronger, probably electrostatic, interactions. Depalmitoylation produced a weakened interaction with either...... phospholipid as deduced from IRRAS spectra and from pi-area isotherms. S-Palmitoylation may modulate peptide hydration and conformation in the N-terminal region of SP-C and may thus permit the peptide to remain in the film at the high surface pressures present during lung compression. The unique capability...... of IRRAS to detect the surface pressure dependence of protein or peptide structure/interactions in a physiologically relevant model for surfactant is clearly demonstrated. Udgivelsesdato: 2002-Jul-2...

  17. Superficial disposition of the N-terminal region of the surfactant protein SP-C and the absence of specific SP-B-SP-C interactions in phospholipid bilayers

    DEFF Research Database (Denmark)

    Plasencia, I; Cruz, A; Casals, C

    2001-01-01

    . The fluorescence emission spectrum of Dns-SP-C in phospholipid bilayers is similar to the spectrum of dansyl-phosphatidylethanolamine, and indicates that the N-terminal end of the protein is located at the surface of the membranes and is exposed to the aqueous environment. In membranes containing...... phosphatidylglycerol (PG), the fluorescence of Dns-SP-C shows a 3-fold increase with respect to the fluorescence of phosphatidylcholine (PC), suggesting that electrostatic lipid-protein interactions induce important effects on the structure and disposition of the N-terminal segment of the protein in these membranes...... of the N-terminal segment of the protein into less polar environments that originate during protein lateral segregation. This suggests that conformation and interactions of the N-terminal segment of SP-C could be important in regulating the lateral distribution of the protein in surfactant bilayers...

  18. Automatic optimisation of beam orientations using the simplex algorithm and optimisation of quality control using statistical process control (S.P.C.) for intensity modulated radiation therapy (I.M.R.T.)

    International Nuclear Information System (INIS)

    Gerard, K.

    2008-11-01

    Intensity Modulated Radiation Therapy (I.M.R.T.) is currently considered as a technique of choice to increase the local control of the tumour while reducing the dose to surrounding organs at risk. However, its routine clinical implementation is partially held back by the excessive amount of work required to prepare the patient treatment. In order to increase the efficiency of the treatment preparation, two axes of work have been defined. The first axis concerned the automatic optimisation of beam orientations. We integrated the simplex algorithm in the treatment planning system. Starting from the dosimetric objectives set by the user, it can automatically determine the optimal beam orientations that best cover the target volume while sparing organs at risk. In addition to time sparing, the simplex results of three patients with a cancer of the oropharynx, showed that the quality of the plan is also increased compared to a manual beam selection. Indeed, for an equivalent or even a better target coverage, it reduces the dose received by the organs at risk. The second axis of work concerned the optimisation of pre-treatment quality control. We used an industrial method: Statistical Process Control (S.P.C.) to retrospectively analyse the absolute dose quality control results performed using an ionisation chamber at Centre Alexis Vautrin (C.A.V.). This study showed that S.P.C. is an efficient method to reinforce treatment security using control charts. It also showed that our dose delivery process was stable and statistically capable for prostate treatments, which implies that a reduction of the number of controls can be considered for this type of treatment at the C.A.V.. (author)

  19. Evaluation of an edge method for computed radiography and an electronic portal imaging device in radiotherapy: image quality measurements

    Energy Technology Data Exchange (ETDEWEB)

    Son, Soon-Yong [Asan Medical Center, Seoul (Korea, Republic of); Choe, Bo-Young [The Catholic University of Korea, Seoul (Korea, Republic of); Lee, Jeong-Woo [Konkuk University Hospital, Seoul (Korea, Republic of); Kim, Jung-Min [Korea University, Seoul (Korea, Republic of); Jeong, Hoi-Woun [The Baekseok Culture University College of Korea, Cheon-an (Korea, Republic of); Kim, Ham-Gyum; Kim, Wha-Sun [The Ansan University College of Korea, Ansan (Korea, Republic of); Lyu, Kwang-Yeul; Min, Jung-Whan [The Shingu University College of Korea, Seongnam (Korea, Republic of); Kim, Ki-Won [Samsung Medical Center, Seoul (Korea, Republic of)

    2014-12-15

    Regular quality assurance (QA) of image quality is essential for reasonable patient dose and accurate treatment. Thus, QA should be performed as a routine for correction. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) of the computed radiography (CR) system and the digital radiography (DR) system by using the edge method in megavoltage X-ray imaging (MVI). We used an edge block, which consisting of tungsten with dimensions of 19 (thickness) x 10 (length) x 1 (width) cm{sup 3} and measured the pre-sampling MTF by using a 6-megavolt (MV) energy. Computed radiography with an image plate (CR-IP) showed the values of 0.4 mm{sup -1} and 1.19 mm{sup -1} for MTF 0.5 and 0.1. In the DR group, Elekta iViewGT showed the highest value of 0.27 mm{sup -1} for MTF 0.5, and Siemens BEAMVIEW{sup PLUS} showed the highest value of 0.98 mm{sup -1} for MTF 0.1. In CR, the NPS of CR-IP showed a favorable noise distribution. Thus, in the DR group, the NPS of Elekta iViewGT showed the highest noise distribution. CR-IP showed values at peak DQE and 1 mm{sup -1} DQE of 0.0013 and 0.00011, respectively. In the DR group, Elekta iViewGT showed the best efficiency at a peak DQE of 0.0009, and Siemens BEAMVIEW{sup PLUS} showed the best efficiency at a 1-mm{sup -1} DQE of 0.000008. The edge method produced fast assessments of the MTF and the DQE. We could validate the evaluation of the edge method by comparing of the CR system to the DR system. This study demonstrated that the edge method can be used for not only traditional QA imaging but also quantitative MTF, NPS and DQE measurements in detector development.

  20. Acceleration performance of individual European sea bass Dicentrarchus labrax measured with a sprint performance chamber: comparison with high-speed cinematography and correlates with ecological performance.

    Science.gov (United States)

    Vandamm, Joshua P; Marras, Stefano; Claireaux, Guy; Handelsman, Corey A; Nelson, Jay A

    2012-01-01

    Locomotor performance can influence the ecological and evolutionary success of a species. For fish, favorable outcomes of predator-prey encounters are often presumably due to robust acceleration ability. Although escape-response or "fast-start" studies utilizing high-speed cinematography are prevalent, little is known about the contribution of relative acceleration performance to ecological or evolutionary success in a species. This dearth of knowledge may be due to the time-consuming nature of analyzing film, which imposes a practical limit on sample sizes. Herein, we present a high-throughput potential alternative for measuring fish acceleration performance using a sprint performance chamber (SPC). The acceleration performance of a large number of juvenile European sea bass (Dicentrarchus labrax) from two populations was analyzed. Animals from both hatchery and natural ontogenies were assessed, and animals of known acceleration ability had their ecological performance measured in a mesocosm environment. Individuals from one population also had their acceleration performance assessed by both high-speed cinematography and an SPC. Acceleration performance measured in an SPC was lower than that measured by classical high-speed video techniques. However, short-term repeatability and interindividual variation of acceleration performance were similar between the two techniques, and the SPC recorded higher sprint swimming velocities. Wild fish were quicker to accelerate in an SPC and had significantly greater accelerations than all groups of hatchery-raised fish. Acceleration performance had no significant effect on ecological performance (as assessed through animal growth and survival in the mesocosms). However, it is worth noting that wild animals did survive predation in the mesocosm better than farmed ones. Moreover, the hatchery-originated fish that survived the mesocosm experiment, when no predators were present, displayed significantly increased acceleration

  1. Novel Accurate Bacterial Discrimination by MALDI-Time-of-Flight MS Based on Ribosomal Proteins Coding in S10-spc-alpha Operon at Strain Level S10-GERMS

    Science.gov (United States)

    Tamura, Hiroto; Hotta, Yudai; Sato, Hiroaki

    2013-08-01

    Matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is one of the most widely used mass-based approaches for bacterial identification and classification because of the simple sample preparation and extremely rapid analysis within a few minutes. To establish the accurate MALDI-TOF MS bacterial discrimination method at strain level, the ribosomal subunit proteins coded in the S 10-spc-alpha operon, which encodes half of the ribosomal subunit protein and is highly conserved in eubacterial genomes, were selected as reliable biomarkers. This method, named the S10-GERMS method, revealed that the strains of genus Pseudomonas were successfully identified and discriminated at species and strain levels, respectively; therefore, the S10-GERMS method was further applied to discriminate the pathovar of P. syringae. The eight selected biomarkers (L24, L30, S10, S12, S14, S16, S17, and S19) suggested the rapid discrimination of P. syringae at the strain (pathovar) level. The S10-GERMS method appears to be a powerful tool for rapid and reliable bacterial discrimination and successful phylogenetic characterization. In this article, an overview of the utilization of results from the S10-GERMS method is presented, highlighting the characterization of the Lactobacillus casei group and discrimination of the bacteria of genera Bacillus and Sphingopyxis despite only two and one base difference in the 16S rRNA gene sequence, respectively.

  2. Characterization of a mammographic system based on single photon counting pixel arrays coupled to GaAs x-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Amendolia, S. R.; Bisogni, M. G.; Delogu, P.; Fantacci, M. E.; Paternoster, G.; Rosso, V.; Stefanini, A. [Str. Dip. di Matematica e Fisica dell' Universita di Sassari, Via Vienna 2, I-07100, Sassari (Italy) and Istituto Nazionale di Fisica Nucleare INFN Sezione di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy); Dip. di Fisica ' ' E. Fermi' ' , Universita di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy) and Istituto Nazionale di Fisica Nucleare INFN Sezione di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy); Dip. di Fisica ' ' E. Fermi' ' , Universita di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy); Dip. di Fisica ' ' E. Fermi' ' , Universita di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy) and Istituto Nazionale di Fisica Nucleare INFN Sezione di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy)

    2009-04-15

    The authors report on the imaging capabilities of a mammographic system demonstrator based on GaAs pixel detectors operating in single photon counting (SPC) mode. The system imaging performances have been assessed by means of the transfer functions: The modulation transfer function (MTF), the normalized noise power spectrum, and the detective quantum efficiency (DQE) have been measured following the guidelines of the IEC 62220-1-2 protocol. The transfer function analysis has shown the high spatial resolution capabilities of the GaAs detectors. The MTF calculated at the Nyquist frequency (2.94 cycles/mm) is indeed 60%. The DQE, measured with a standard mammographic beam setup (Mo/Mo, 28 kVp, with 4 mm Al added filter) and calculated at zero frequency, is 46%. Aiming to further improve the system's image quality, the authors investigate the DQE limiting factors and show that they are mainly related to system engineering. For example, the authors show that optimization of the image equalization procedure increases the DQE(0) up to 74%, which is better than the DQE(0) of most clinical mammographic systems. The authors show how the high detection efficiency of GaAs detectors and the noise discrimination associated with the SPC technology allow optimizing the image quality in mammography. In conclusion, the authors propose technological solutions to exploit to the utmost the potentiality of GaAs detectors coupled to SPC electronics.

  3. MFP scanner diagnostics using a self-printed target to measure the modulation transfer function

    Science.gov (United States)

    Wang, Weibao; Bauer, Peter; Wagner, Jerry; Allebach, Jan P.

    2014-01-01

    In the current market, reduction of warranty costs is an important avenue for improving profitability by manufacturers of printer products. Our goal is to develop an autonomous capability for diagnosis of printer and scanner caused defects with mid-range laser multifunction printers (MFPs), so as to reduce warranty costs. If the scanner unit of the MFP is not performing according to specification, this issue needs to be diagnosed. If there is a print quality issue, this can be diagnosed by printing a special test page that is resident in the firmware of the MFP unit, and then scanning it. However, the reliability of this process will be compromised if the scanner unit is defective. Thus, for both scanner and printer image quality issues, it is important to be able to properly evaluate the scanner performance. In this paper, we consider evaluation of the scanner performance by measuring its modulation transfer function (MTF). The MTF is a fundamental tool for assessing the performance of imaging systems. Several ways have been proposed to measure the MTF, all of which require a special target, for example a slanted-edge target. It is unacceptably expensive to ship every MFP with such a standard target, and to expect that the customer can keep track of it. To reduce this cost, in this paper, we develop new approach to this task. It is based on a self-printed slanted-edge target. Then, we propose algorithms to improve the results using a self-printed slanted-edge target. Finally, we present experimental results for MTF measurement using self-printed targets and compare them to the results obtained with standard targets.

  4. Scanners for analytic print measurement: the devil in the details

    Science.gov (United States)

    Zeise, Eric K.; Williams, Don; Burns, Peter D.; Kress, William C.

    2007-01-01

    Inexpensive and easy-to-use linear and area-array scanners have frequently substituted as colorimeters and densitometers for low-frequency (i.e., large area) hard copy image measurement. Increasingly, scanners are also being used for high spatial frequency, image microstructure measurements, which were previously reserved for high performance microdensitometers. In this paper we address characteristics of flatbed reflection scanners in the evaluation of print uniformity, geometric distortion, geometric repeatability and the influence of scanner MTF and noise on analytic measurements. Suggestions are made for the specification and evaluation of scanners to be used in print image quality standards that are being developed.

  5. Measurement

    NARCIS (Netherlands)

    Boumans, M.; Durlauf, S.N.; Blume, L.E.

    2008-01-01

    Measurement theory takes measurement as the assignment of numbers to properties of an empirical system so that a homomorphism between the system and a numerical system is established. To avoid operationalism, two approaches can be distinguished. In the axiomatic approach it is asserted that if the

  6. Fieldcrest Cannon, Inc. Advanced Technical Preparation. Statistical Process Control (SPC). PRE-SPC 11: SPC & Graphs. Instructor Book.

    Science.gov (United States)

    Averitt, Sallie D.

    This instructor guide, which was developed for use in a manufacturing firm's advanced technical preparation program, contains the materials required to present a learning module that is designed to prepare trainees for the program's statistical process control module by improving their basic math skills in working with line graphs and teaching…

  7. WE-DE-207B-05: Measuring Spatial Resolution in Digital Breast Tomosynthesis: Update of AAPM Task Group 245

    Energy Technology Data Exchange (ETDEWEB)

    Scaduto, DA; Hu, Y-H; Zhao, W [Stony Brook Medicine, Stony Brook, NY (United States); Goodsitt, M; Chan, H-P [University Michigan, Ann Arbor, MI (United States); Olafsdottir, H [Image Owl, 105 Reykjavik (Iceland); Das, M [University Houston, Houston, TX (United States); Fredenberg, E [Philips Healthcare, Solna (Sweden); Geiser, W [UT MD Anderson Cancer Center, Houston, TX (United States); Goodenough, D [The George Washington University, Washington, DC (United States); Heid, P [ARCADES, Marseille (France); Liu, B [Massachusetts General Hospital, Boston, MA (United States); Mainprize, J [Sunnybrook Health Sciences Centre, North York, ON (Canada); Reiser, I [The University of Chicago, Chicago, IL (United States); Van Engen, R [LRCB, Nijmegen (Netherlands); Varchena, V [CIRS Inc., Norfolk, VA (United States); Vecchio, S [I.M.S., Pontecchio Marconi (Italy); Glick, S [Food and Drug Administration, Silver Spring, MD (United States)

    2016-06-15

    Purpose: Spatial resolution in digital breast tomosynthesis (DBT) is affected by inherent/binned detector resolution, oblique entry of x-rays, and focal spot size/motion; the limited angular range further limits spatial resolution in the depth-direction. While DBT is being widely adopted clinically, imaging performance metrics and quality control protocols have not been standardized. AAPM Task Group 245 on Tomosynthesis Quality Control has been formed to address this deficiency. Methods: Methods of measuring spatial resolution are evaluated using two prototype quality control phantoms for DBT. Spatial resolution in the detector plane is measured in projection and reconstruction domains using edge-spread function (ESF), point-spread function (PSF) and modulation transfer function (MTF). Spatial resolution in the depth-direction and effective slice thickness are measured in the reconstruction domain using slice sensitivity profile (SSP) and artifact spread function (ASF). An oversampled PSF in the depth-direction is measured using a 50 µm angulated tungsten wire, from which the MTF is computed. Object-dependent PSF is derived and compared with ASF. Sensitivity of these measurements to phantom positioning, imaging conditions and reconstruction algorithms is evaluated. Results are compared from systems of varying acquisition geometry (9–25 projections over 15–60°). Dependence of measurements on feature size is investigated. Results: Measurements of spatial resolution using PSF and LSF are shown to depend on feature size; depth-direction spatial resolution measurements are shown to similarly depend on feature size for ASF, though deconvolution with an object function removes feature size-dependence. A slanted wire may be used to measure oversampled PSFs, from which MTFs may be computed for both in-plane and depth-direction resolution. Conclusion: Spatial resolution measured using PSF is object-independent with sufficiently small object; MTF is object

  8. Measurement of cone beam CT coincidence with megavoltage isocentre and image sharpness using the QUASAR Penta-Guide phantom.

    Science.gov (United States)

    Sykes, J R; Lindsay, R; Dean, C J; Brettle, D S; Magee, D R; Thwaites, D I

    2008-10-07

    For image-guided radiotherapy (IGRT) systems based on cone beam CT (CBCT) integrated into a linear accelerator, the reproducible alignment of imager to x-ray source is critical to the registration of both the x-ray-volumetric image with the megavoltage (MV) beam isocentre and image sharpness. An enhanced method of determining the CBCT to MV isocentre alignment using the QUASAR Penta-Guide phantom was developed which improved both precision and accuracy. This was benchmarked against our existing method which used software and a ball-bearing (BB) phantom provided by Elekta. Additionally, a method of measuring an image sharpness metric (MTF(50)) from the edge response function of a spherical air cavity within the Penta-Guide phantom was developed and its sensitivity was tested by simulating misalignments of the kV imager. Reproducibility testing of the enhanced Penta-Guide method demonstrated a systematic error of <0.2 mm when compared to the BB method with near equivalent random error (s=0.15 mm). The mean MTF(50) for five measurements was 0.278+/-0.004 lp mm(-1) with no applied misalignment. Simulated misalignments exhibited a clear peak in the MTF(50) enabling misalignments greater than 0.4 mm to be detected. The Penta-Guide phantom can be used to precisely measure CBCT-MV coincidence and image sharpness on CBCT-IGRT systems.

  9. Measuring $\

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Jessica Sarah [Univ. of Cambridge (United Kingdom)

    2011-01-01

    The MINOS Experiment consists of two steel-scintillator calorimeters, sampling the long baseline NuMI muon neutrino beam. It was designed to make a precise measurement of the ‘atmospheric’ neutrino mixing parameters, Δm2 atm. and sin2 (2 atm.). The Near Detector measures the initial spectrum of the neutrino beam 1km from the production target, and the Far Detector, at a distance of 735 km, measures the impact of oscillations in the neutrino energy spectrum. Work performed to validate the quality of the data collected by the Near Detector is presented as part of this thesis. This thesis primarily details the results of a vμ disappearance analysis, and presents a new sophisticated fitting software framework, which employs a maximum likelihood method to extract the best fit oscillation parameters. The software is entirely decoupled from the extrapolation procedure between the detectors, and is capable of fitting multiple event samples (defined by the selections applied) in parallel, and any combination of energy dependent and independent sources of systematic error. Two techniques to improve the sensitivity of the oscillation measurement were also developed. The inclusion of information on the energy resolution of the neutrino events results in a significant improvement in the allowed region for the oscillation parameters. The degree to which sin2 (2θ )= 1.0 could be disfavoured with the exposure of the current dataset if the true mixing angle was non-maximal, was also investigated, with an improved neutrino energy reconstruction for very low energy events. The best fit oscillation parameters, obtained by the fitting software and incorporating resolution information were: | Δm2| = 2.32+0.12 -0.08×10-3 eV2 and sin2 (2θ ) > 0.90(90% C.L.). The analysis provides the current world best measurement of the atmospheric neutrino mass

  10. Systematic review of the use of Statistical Process Control methods to measure the success of pressure ulcer prevention.

    Science.gov (United States)

    Clark, Michael; Young, Trudie; Fallon, Maureen

    2018-06-01

    Successful prevention of pressure ulcers is the end product of a complex series of care processes including, but not limited to, the assessment of vulnerability to pressure damage; skin assessment and care; nutritional support; repositioning; and the use of beds, mattresses, and cushions to manage mechanical loads on the skin and soft tissues. The purpose of this review was to examine where and how Statistical Process Control (SPC) measures have been used to assess the success of quality improvement initiatives intended to improve pressure ulcer prevention. A search of 7 electronic bibliographic databases was performed on May 17th, 2017, for studies that met the inclusion criteria. SPC methods have been reported in 9 publications since 2010 to interpret changes in the incidence of pressure ulcers over time. While these methods offer rapid interpretation of changes in incidence than is gained from a comparison of 2 arbitrarily selected time points pre- and post-implementation of change, more work is required to ensure that the clinical and scientific communities adopt the most appropriate SPC methods. © 2018 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  11. [Comparative quality measurements part 3: funnel plots].

    Science.gov (United States)

    Kottner, Jan; Lahmann, Nils

    2014-02-01

    Comparative quality measurements between organisations or institutions are common. Quality measures need to be standardised and risk adjusted. Random error must also be taken adequately into account. Rankings without consideration of the precision lead to flawed interpretations and enhances "gaming". Application of confidence intervals is one possibility to take chance variation into account. Funnel plots are modified control charts based on Statistical Process Control (SPC) theory. The quality measures are plotted against their sample size. Warning and control limits that are 2 or 3 standard deviations from the center line are added. With increasing group size the precision increases and so the control limits are forming a funnel. Data points within the control limits are considered to show common cause variation; data points outside special cause variation without the focus of spurious rankings. Funnel plots offer data based information about how to evaluate institutional performance within quality management contexts.

  12. Fieldcrest Cannon, Inc. Advanced Technical Preparation. Statistical Process Control (SPC). PRE-SPC I. Instructor Book.

    Science.gov (United States)

    Averitt, Sallie D.

    This instructor guide, which was developed for use in a manufacturing firm's advanced technical preparation program, contains the materials required to present a learning module that is designed to prepare trainees for the program's statistical process control module by improving their basic math skills and instructing them in basic calculator…

  13. The CMS Modular Track Finder Boards, MTF6 and MTF7

    CERN Document Server

    Acosta, Darin Edward; Carnes, Andrew Mathew; Carver, Matthew Robert; Curry, David Alexander; Di Giovanni, Gian Piero; Furic, Ivan-Kresimir; Kropivnitskaya, Anna; Madorsky, Alexander; Matveev, Mikhail; Padley, Paul; Rank, Douglas; Reeves, C; Scurlock, Bobby; Wang, S

    2013-01-01

    To satisfy these requirements, a new Sector Processor unit for muon track finding is being designed. This unit follows the micro-TCA standard recently adopted by CMS. It consists of three modules. The Core Logic module houses the large FPGA that contains the processing logic and multi-gigabit serial links for data exchange. The Optical module contains optical receivers and transmitters; it communicates with the Core Logic module via a custom backplane section. The Look-up Table module contains a large amount of low-latency memory that is us...

  14. Measurement of optical blurring in a turbulent cloud chamber

    Science.gov (United States)

    Packard, Corey D.; Ciochetto, David S.; Cantrell, Will H.; Roggemann, Michael C.; Shaw, Raymond A.

    2016-10-01

    Earth's atmosphere can significantly impact the propagation of electromagnetic radiation, degrading the performance of imaging systems. Deleterious effects of the atmosphere include turbulence, absorption and scattering by particulates. Turbulence leads to blurring, while absorption attenuates the energy that reaches imaging sensors. The optical properties of aerosols and clouds also impact radiation propagation via scattering, resulting in decorrelation from unscattered light. Models have been proposed for calculating a point spread function (PSF) for aerosol scattering, providing a method for simulating the contrast and spatial detail expected when imaging through atmospheres with significant aerosol optical depth. However, these synthetic images and their predicating theory would benefit from comparison with measurements in a controlled environment. Recently, Michigan Technological University (MTU) has designed a novel laboratory cloud chamber. This multiphase, turbulent "Pi Chamber" is capable of pressures down to 100 hPa and temperatures from -55 to +55°C. Additionally, humidity and aerosol concentrations are controllable. These boundary conditions can be combined to form and sustain clouds in an instrumented laboratory setting for measuring the impact of clouds on radiation propagation. This paper describes an experiment to generate mixing and expansion clouds in supersaturated conditions with salt aerosols, and an example of measured imagery viewed through the generated cloud is shown. Aerosol and cloud droplet distributions measured during the experiment are used to predict scattering PSF and MTF curves, and a methodology for validating existing theory is detailed. Measured atmospheric inputs will be used to simulate aerosol-induced image degradation for comparison with measured imagery taken through actual cloud conditions. The aerosol MTF will be experimentally calculated and compared to theoretical expressions. The key result of this study is the

  15. Resolution and noise measurements of five CRT and LCD medical displays

    International Nuclear Information System (INIS)

    Saunders, Robert S. Jr.; Samei, Ehsan

    2006-01-01

    The performance of soft-copy displays plays a significant role in the overall image quality of a digital radiographic system. In this work, we discuss methods to characterize the resolution and noise of both cathode ray tube (CRT) and liquid crystal display (LCD) devices. We measured the image quality of five different commercial display devices, representing both CRT and LCD technologies, using a high-quality charge-coupled device (CCD) camera. The modulation transfer function (MTF) was calculated using the line technique, correcting for the MTF of the CCD camera and the display pixel size. The normalized noise power spectrum (NPS) was computed from two-dimensional Fourier analysis of uniform images. To separate the effects of pixel structure from interpixel luminance variations, we created structure-free images by eliminating the pixel structures of the display device. The NPS was then computed from these structure-free images to isolate interpixel luminance variations. We found that the MTF of LCDs remained close to the theoretical limit dictated by their inherent pixel size (0.85±0.08 at Nyquist frequency), in contrast to the MTF for the two CRT displays, which dropped to 0.15±0.08 at the Nyquist frequency. However, the NPS of LCDs showed significant peaks due to the subpixel structure, while the NPS of CRT displays exhibited a nearly flat power spectrum. After removing the pixel structure, the structured noise peaks for LCDs were eliminated and the overall noise magnitude was significantly reduced. The average total noise-to-signal ratio for CRT displays was 6.55%±0.59%, of which 6.03%±0.24% was due to interpixel luminance variations, while LCD displays had total noise to signal ratios of 46.1%±5.1% of which 1.50%±0.41% were due to interpixel luminance variations. Depending on the extent of the blurring and prewhitening processes of the human visual system, the magnitude of the display noise (including pixel structure) potentially perceived by the

  16. [Comparison of ocular modulation transfer function measurements by ray tracing wavefront technology and double-pass system].

    Science.gov (United States)

    Qiao, Liya; Cai, Xiaogu; Wan, Xiuhua; Guan, Zheng; Xiong, Ying; Lin, Zhong; Zhang, Ye; Tan, Jiaxuan; Wang, Ningli

    2015-01-01

    To compare the agreement of the ocular modulation transfer function (MTF) measured by double-pass system and ray tracing wavefront aberrometry, and to analyze the correlations of two MTFs with the visual acuity and contrast sensitivity function results. Comparative study. Subjects with no ocular diseases were consecutively enrolled in an epidemic study field located at the Dongyangzhuang Health Center, Yongnian County, Handan City, Hebei Province, China. After comprehensive ophthalmic examinations, the mean values of subtracted lower order aberration MTF at 5, 10, 15, 20, 25, and 30 cycle/degree(c/d) spatial frequencies were obtained with a double-pass system (optical quality analysis system II, OQAS II system) and a ray tracing wavefront aberrometer (iTrace visual function analyzer, iTrace system) in the 4.0 mm and 6.0 mm pupil after dilation, respectively. Paired-sample t test and Bland-Altman analysis were used to compare the difference and agreement of MTFs obtained with two instruments. Correlation analysis was preformed between two MTF measurement results and subjective visual quality including visual acuity and contrast sensitivity function. Two hundred and fifty-one healthy eyes of 163 subjects were enrolled, aged 30 to 60, mean (44.1 ± 9.7) years, including 139 eyes of 81 males and 112 eyes of 82 females. The mean value of MTF at 5, 10, 15, 20.25, 30 c/d obtained by iTrace in 4.0 mm pupil were 0.730 ± 0.138, 0.431 ± 0.159, 0.262 ± 0.120, 0.169 ± 0.078, 0.118 ± 0.053, 0.094 ± 0.043. The value obtained by OQASII were 0.347 ± 0.123, 0.162 ± 0.086, 0.072 ± 0.049, 0.042 ± 0.033, 0.026 ± 0.022, 0.017 ± 0.022, The result of iTrace were all significant higher than OQAS in both 4mm(t = 38.72, 28.03, 27.32, 27.59, 29.23, 28.96, P < 0.01) and 6.0 mm(t = 4.60, 3.19, 9.34, 13.41, 16.96, 20.24, P < 0.01)pupil diameter. The iTrace-OQAS II MTF difference was smaller in the 6.0 mm pupil. Bland-Altman analysis indicated that the agreement of two instruments was

  17. Robust and efficient modulation transfer function measurement with CMOS color sensors

    Science.gov (United States)

    Farsani, Raziyeh A.; Sure, Thomas; Apel, Uwe

    2017-06-01

    Increasing challenges of the industry to improve camera performance with control and test of the alignment process will be discussed in this paper. The major difficulties, such as special CFAs that have white/clear pixels instead of a Bayer pattern and non-homogeneous back light illumination of the targets, used for such tests, will be outlined and strategies on how to handle them will be presented. The proposed algorithms are applied to synthetically generated edges, as well as to experimental images taken from ADAS cameras in standard illumination conditions, to validate the approach. In addition, to consider the influence of the chromatic aberration of the lens and the CFA's influence on the total system MTF, the on-axis focus behavior of the camera module will be presented for each pixel class separately. It will be shown that the repeatability of the measurement results of the system MTF is improved, as a result of a more accurate and robust edge angle detection, elimination of systematic errors, using an improved lateral shift of the pixels and analytical modeling of the edge transition. Results also show the necessity to have separated measurements of contrast in the different pixel classes to ensure a precise focus position.

  18. On the relationships between higher and lower bit-depth system measurements

    Science.gov (United States)

    Burks, Stephen D.; Haefner, David P.; Doe, Joshua M.

    2018-04-01

    The quality of an imaging system can be assessed through controlled laboratory objective measurements. Currently, all imaging measurements require some form of digitization in order to evaluate a metric. Depending on the device, the amount of bits available, relative to a fixed dynamic range, will exhibit quantization artifacts. From a measurement standpoint, measurements are desired to be performed at the highest possible bit-depth available. In this correspondence, we described the relationship between higher and lower bit-depth measurements. The limits to which quantization alters the observed measurements will be presented. Specifically, we address dynamic range, MTF, SiTF, and noise. Our results provide guidelines to how systems of lower bit-depth should be characterized and the corresponding experimental methods.

  19. Measuring the spatial resolution of an optical system in an undergraduate optics laboratory

    Science.gov (United States)

    Leung, Calvin; Donnelly, T. D.

    2017-06-01

    Two methods of quantifying the spatial resolution of a camera are described, performed, and compared, with the objective of designing an imaging-system experiment for students in an undergraduate optics laboratory. With the goal of characterizing the resolution of a typical digital single-lens reflex (DSLR) camera, we motivate, introduce, and show agreement between traditional test-target contrast measurements and the technique of using Fourier analysis to obtain the modulation transfer function (MTF). The advantages and drawbacks of each method are compared. Finally, we explore the rich optical physics at work in the camera system by calculating the MTF as a function of wavelength and f-number. For example, we find that the Canon 40D demonstrates better spatial resolution at short wavelengths, in accordance with scalar diffraction theory, but is not diffraction-limited, being significantly affected by spherical aberration. The experiment and data analysis routines described here can be built and written in an undergraduate optics lab setting.

  20. Comparison of modulation transfer function, noise power spectrum, and sensitometric measurements of x-ray screen-film systems made in two different laboratories

    International Nuclear Information System (INIS)

    Sandrik, J.M.; Jennings, R.J.; Wagner, R.F.

    1980-01-01

    A project to develop standardization in the measurement of fundamental characteristics of screen-film systems is described. This project is a comparison of measurements on the same film samples performed by both the Kurt Rossmann Laboratories for Radiologic Image Research at the University of Chicago and by the Radiologic Imaging Section in the Medical Physics Branch, Division of Electronic Products. For this comparison we are making three fundamental measurements that characterize the operation of the screen-film systems. One is sensitometry of the characteristic or H and D curve. The film darkening is studied as a function of x-ray exposure to the screen-film system. This provides information on the speed and contrast of the system and it is also used in the determination of the MTF. The second measurement is the spatial frequency response or the MTF. For this measurement the screen-film system is exposed through a slit about 10 microns wide. This provides information on the fidelity with which contrast in the object is transferred to the image and information on the resolution of the image receptor. The third measure is the noise power or Wiener spectrum. In this case the film is exposed to a uniform x-ray field and the image provides information on the noise content of the receptor as a function of spatial frequency so that the effect of noise on the signal can be assessed

  1. Light-reflection random-target method for measurement of the modulation transfer function of a digital video-camera

    Science.gov (United States)

    Pospisil, J.; Jakubik, P.; Machala, L.

    2005-11-01

    This article reports the suggestion, realization and verification of the newly developed measuring means of the noiseless and locally shift-invariant modulation transfer function (MTF) of a digital video camera in a usual incoherent visible region of optical intensity, especially of its combined imaging, detection, sampling and digitizing steps which are influenced by the additive and spatially discrete photodetector, aliasing and quantization noises. Such means relates to the still camera automatic working regime and static two-dimensional spatially continuous light-reflection random target of white-noise property. The introduced theoretical reason for such a random-target method is also performed under exploitation of the proposed simulation model of the linear optical intensity response and possibility to express the resultant MTF by a normalized and smoothed rate of the ascertainable output and input power spectral densities. The random-target and resultant image-data were obtained and processed by means of a processing and evaluational PC with computation programs developed on the basis of MATLAB 6.5E The present examples of results and other obtained results of the performed measurements demonstrate the sufficient repeatability and acceptability of the described method for comparative evaluations of the performance of digital video cameras under various conditions.

  2. Automatic optimisation of beam orientations using the simplex algorithm and optimisation of quality control using statistical process control (S.P.C.) for intensity modulated radiation therapy (I.M.R.T.); Optimisation automatique des incidences des faisceaux par l'algorithme du simplexe et optimisation des controles qualite par la Maitrise Statistique des Processus (MSP) en Radiotherapie Conformationnelle par Modulation d'Intensite (RCMI)

    Energy Technology Data Exchange (ETDEWEB)

    Gerard, K

    2008-11-15

    Intensity Modulated Radiation Therapy (I.M.R.T.) is currently considered as a technique of choice to increase the local control of the tumour while reducing the dose to surrounding organs at risk. However, its routine clinical implementation is partially held back by the excessive amount of work required to prepare the patient treatment. In order to increase the efficiency of the treatment preparation, two axes of work have been defined. The first axis concerned the automatic optimisation of beam orientations. We integrated the simplex algorithm in the treatment planning system. Starting from the dosimetric objectives set by the user, it can automatically determine the optimal beam orientations that best cover the target volume while sparing organs at risk. In addition to time sparing, the simplex results of three patients with a cancer of the oropharynx, showed that the quality of the plan is also increased compared to a manual beam selection. Indeed, for an equivalent or even a better target coverage, it reduces the dose received by the organs at risk. The second axis of work concerned the optimisation of pre-treatment quality control. We used an industrial method: Statistical Process Control (S.P.C.) to retrospectively analyse the absolute dose quality control results performed using an ionisation chamber at Centre Alexis Vautrin (C.A.V.). This study showed that S.P.C. is an efficient method to reinforce treatment security using control charts. It also showed that our dose delivery process was stable and statistically capable for prostate treatments, which implies that a reduction of the number of controls can be considered for this type of treatment at the C.A.V.. (author)

  3. Reproducibility analysis of measurements with a mechanical semiautomatic eye model for evaluation of intraocular lenses

    Science.gov (United States)

    Rank, Elisabet; Traxler, Lukas; Bayer, Natascha; Reutterer, Bernd; Lux, Kirsten; Drauschke, Andreas

    2014-03-01

    Mechanical eye models are used to validate ex vivo the optical quality of intraocular lenses (IOLs). The quality measurement and test instructions for IOLs are defined in the ISO 11979-2. However, it was mentioned in literature that these test instructions could lead to inaccurate measurements in case of some modern IOL designs. Reproducibility of alignment and measurement processes are presented, performed with a semiautomatic mechanical ex vivo eye model based on optical properties published by Liou and Brennan in the scale 1:1. The cornea, the iris aperture and the IOL itself are separately changeable within the eye model. The adjustment of the IOL can be manipulated by automatic decentration and tilt of the IOL in reference to the optical axis of the whole system, which is defined by the connection line of the central point of the artificial cornea and the iris aperture. With the presented measurement setup two quality criteria are measurable: the modulation transfer function (MTF) and the Strehl ratio. First the reproducibility of the alignment process for definition of initial conditions of the lateral position and tilt in reference to the optical axis of the system is investigated. Furthermore, different IOL holders are tested related to the stable holding of the IOL. The measurement is performed by a before-after comparison of the lens position using a typical decentration and tilt tolerance analysis path. Modulation transfer function MTF and Strehl ratio S before and after this tolerance analysis are compared and requirements for lens holder construction are deduced from the presented results.

  4. Benefit Analysis of SPC Panel SP-10 Projects

    Science.gov (United States)

    1995-12-01

    NUCOR from Michigan, deals primarily with the automotive industry but with the decline in the auto industry, they are looking for a new market and...shipbuilding is one of those they are looking at. NUCOR is going to send them a proposal for both the material handling system. This is a unique company

  5. Digital SPC Switching Technology--Foreign Technology Assessment

    Science.gov (United States)

    1990-12-01

    India C DOT MAX C DOT DSS 0 TDX 1 Samsung , Goldstar Korea TDX 10 Daewoo, Otelco (ROK) System X Plessey/GEC U.K. (Siemens) Fetex 150 Fujitsu Japan HDX...x South Korea Alcatel ATT Malaysia Ericsson NEC New Zealand NEC Philippines DAEWOO Siemens Singapore Fujitsu (AU-, NEC Gateway Switches) Taiwan...Yes Israel Northern Telecom DMS 10 Telrad Yes OMS 100 * Malaysia Ericsson AXE Pewira Ericsson Future SDN BHD Mexico Alcatel System 12 Indetel No

  6. Benefit Analysis of SPC Panel SP-2 Projects

    National Research Council Canada - National Science Library

    Robinson, Rodney A

    1993-01-01

    This Task has investigated the benefits derived from the projects sponsored by SNAME Ship Production Committee Panel SP-2 on Outfitting and Production Aids during the 15 year period when this Panel...

  7. Oversampling in the computed tomography measurements applied for bone structure studies as a method of spatial resolution improvement

    International Nuclear Information System (INIS)

    Tatoń, Grzegorz; Rokita, Eugeniusz; Rok, Tomasz; Beckmann, Felix

    2012-01-01

    Our purpose was to check the potential ability of oversampling as a method for computed tomography axial resolution improvement. The method of achieving isotropic and fine resolution, when the scanning system is characterized by anisotropic resolutions is proposed. In case of typical clinical system the axial resolution is much lower than the planar one. The idea relies on the scanning with a wide overlapping layers and subsequent resolution recovery on the level of scanning step. Simulated three-dimensional images, as well as the real microtomographic images of rat femoral bone were used in proposed solution tests. Original high resolution images were virtually scanned with a wide beam and a small step in order to simulate the real measurements. The low resolution image series were subsequently processed in order to back to the original fine one. Original, virtually scanned and recovered images resolutions were compared with the use of modulation transfer function (MTF). A good ability of oversampling as a method for the resolution recovery was showed. It was confirmed by comparing the resolving powers after and before resolution recovery. The MTF analysis showed resolution improvement. The resolution improvement was achieved but the image noise raised considerably, which is clearly visible on image histograms. Despite this disadvantage the proposed method can be successfully used in practice, especially in the trabecular bone studies because of high contrast between trabeculae and intertrabecular spaces

  8. Measurement of cone beam CT coincidence with megavoltage isocentre and image sharpness using the QUASAR(TM) Penta-Guide phantom

    International Nuclear Information System (INIS)

    Sykes, J R; Lindsay, R; Dean, C J; Thwaites, D I; Brettle, D S; Magee, D R

    2008-01-01

    For image-guided radiotherapy (IGRT) systems based on cone beam CT (CBCT) integrated into a linear accelerator, the reproducible alignment of imager to x-ray source is critical to the registration of both the x-ray-volumetric image with the megavoltage (MV) beam isocentre and image sharpness. An enhanced method of determining the CBCT to MV isocentre alignment using the QUASAR(TM) Penta-Guide phantom was developed which improved both precision and accuracy. This was benchmarked against our existing method which used software and a ball-bearing (BB) phantom provided by Elekta. Additionally, a method of measuring an image sharpness metric (MTF 50 ) from the edge response function of a spherical air cavity within the Penta-Guide phantom was developed and its sensitivity was tested by simulating misalignments of the kV imager. Reproducibility testing of the enhanced Penta-Guide method demonstrated a systematic error of 50 for five measurements was 0.278 ± 0.004 lp mm -1 with no applied misalignment. Simulated misalignments exhibited a clear peak in the MTF 50 enabling misalignments greater than 0.4 mm to be detected. The Penta-Guide phantom can be used to precisely measure CBCT-MV coincidence and image sharpness on CBCT-IGRT systems

  9. Assessment of the global trigger tool to measure, monitor and evaluate pateint safety in cancer patients

    DEFF Research Database (Denmark)

    Otto Mattsson, Thea; Lehmann-Knudsen, Janne; Lauritsen, Jens M

    2013-01-01

    BACKGROUND: Countries around the world are currently aiming to improve patient safety by means of the Institute for Healthcare Improvement global trigger tool (GTT), which is considered a valid tool for evaluating and measuring patient safety within organisations. So far, only few data....... RESULTS: Only 31% of adverse events (AE) were identified by both teams, and further differences in categorisation of identical events was found. Moderate interrater agreement (κ=0.45) between teams gave rise to different conclusions on the patient safety process when monitoring using SPC charts. The Bland......-Altman plot suggests little systematic error but large random error. CONCLUSIONS: Review teams may identify different AE and reach different conclusions on the safety process when using the GTT on identical charts. Tracking true change in the safety level is difficult due to measurement error of the GTT...

  10. Automatic detection of health changes using statistical process control techniques on measured transfer times of elderly.

    Science.gov (United States)

    Baldewijns, Greet; Luca, Stijn; Nagels, William; Vanrumste, Bart; Croonenborghs, Tom

    2015-01-01

    It has been shown that gait speed and transfer times are good measures of functional ability in elderly. However, data currently acquired by systems that measure either gait speed or transfer times in the homes of elderly people require manual reviewing by healthcare workers. This reviewing process is time-consuming. To alleviate this burden, this paper proposes the use of statistical process control methods to automatically detect both positive and negative changes in transfer times. Three SPC techniques: tabular CUSUM, standardized CUSUM and EWMA, known for their ability to detect small shifts in the data, are evaluated on simulated transfer times. This analysis shows that EWMA is the best-suited method with a detection accuracy of 82% and an average detection time of 9.64 days.

  11. Radio Frequency Identification (RFID) for Naval Medical Treatment Facilities (MTF)

    Science.gov (United States)

    2006-09-01

    education and develop my technical knowledge in the field of Information Technology Management. The skills and understanding I gained from my...place, preventing the need for manipulation. The passes can also be used to locate skiers in case of injuries or for the location of children. RFID...created and backed by the leaders of the industry [24]. Intellectual property, patents, 42 intimate technical knowledge and publicity are all

  12. Measurements of field decay and snapback effect on Tevatron dipole and quadrupole magnets

    Energy Technology Data Exchange (ETDEWEB)

    Velev, G.V.; Ambrosio, G.; Annala, G.; Bauer, P.; Carcagno, R.; DiMarco, J.; Glass, H.; Hanft, R.; Kephart, R.; Lamm, M.; Martens, M.; Schlabach, P.; Sylvester, C.; Tartaglia, M.; Tompkins, J.; /Fermilab

    2005-05-01

    Since the beginning of 2002 an intensive measurement program has been performed at the Fermilab Magnet Test Facility (MTF) to understand dynamic effects in Tevatron magnets. Based on the results of this program a new correction algorithm was proposed to compensate for the decay of the sextupole field during the dwell at injection and for the subsequent field ''snapback'' during the first few seconds of the energy ramp. Beam studies showed that the new correction algorithm works better than the original one, and improves the Tevatron efficiency by at least 3%. The beam studies also indicated insufficient correction during the first 6s of the injection plateau where an unexpected discrepancy of 0.15 sextupole units of extra drift was observed. This paper reports on the most recent measurements of the Tevatron dipoles field at the beginning of the injection plateau. Results on the field decay and snapback in the Tevatron quadrupoles are also presented.

  13. Measurements of field decay and snapback effect on Tevatron dipole and quadrupole magnets

    International Nuclear Information System (INIS)

    Velev, G.V.; Ambrosio, G.; Annala, G.; Bauer, P.; Carcagno, R.; DiMarco, J.; Glass, H.; Hanft, R.; Kephart, R.; Lamm, M.; Martens, M.; Schlabach, P.; Sylvester, C.; Tartaglia, M.; Tompkins, J.

    2005-01-01

    Since the beginning of 2002 an intensive measurement program has been performed at the Fermilab Magnet Test Facility (MTF) to understand dynamic effects in Tevatron magnets. Based on the results of this program a new correction algorithm was proposed to compensate for the decay of the sextupole field during the dwell at injection and for the subsequent field ''snapback'' during the first few seconds of the energy ramp. Beam studies showed that the new correction algorithm works better than the original one, and improves the Tevatron efficiency by at least 3%. The beam studies also indicated insufficient correction during the first 6s of the injection plateau where an unexpected discrepancy of 0.15 sextupole units of extra drift was observed. This paper reports on the most recent measurements of the Tevatron dipoles field at the beginning of the injection plateau. Results on the field decay and snapback in the Tevatron quadrupoles are also presented

  14. Optical Performance of Breadboard Amon-Ra Imaging Channel Instrument for Deep Space Albedo Measurement

    Directory of Open Access Journals (Sweden)

    Won Hyun Park

    2007-03-01

    Full Text Available The AmonRa instrument, the primary payload of the international EARTHSHINE mission, is designed for measurement of deep space albedo from L1 halo orbit. We report the optical design, tolerance analysis and the optical performance of the breadborad AmonRa imaging channel instrument optimized for the mission science requirements. In particular, an advanced wavefront feedback process control technique was used for the instrumentation process including part fabrication, system alignment and integration. The measured performances for the complete breadboard system are the RMS 0.091 wave(test wavelength: 632.8 nm in wavefront error, the ensquared energy of 61.7%(in 14 μ m and the MTF of 35.3%(Nyquist frequency: 35.7 mm^{-1} at the center field. These resulting optical system performances prove that the breadboard AmonRa instrument, as built, satisfies the science requirements of the EARTHSHINE mission.

  15. Near-surface current meter array measurements of internal gravity waves

    Energy Technology Data Exchange (ETDEWEB)

    Jones, H.B.E. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    We have developed various processing algorithms used to estimate the wave forms produced by hydrodynamic Internal Waves. Furthermore, the estimated Internal Waves are used to calculate the Modulation Transfer Function (MTF) which relates the current and strain rate subsurface fields to surface scattering phenomenon imaged by radar. Following a brief discussion of LLNL`s measurement platform (a 10 sensor current meter array) we described the generation of representative current and strain rate space-time images from measured or simulated data. Then, we present how our simulation capability highlighted limitations in estimating strain rate. These limitations spurred the application of beamforming techniques to enhance our estimates, albeit at the expense of collapsing our space-time images to 1-D estimates. Finally, we discuss progress with regard to processing the current meter array data captured during the recent Loch Linnhe field trials.

  16. Measurement methods to build up the digital optical twin

    Science.gov (United States)

    Prochnau, Marcel; Holzbrink, Michael; Wang, Wenxin; Holters, Martin; Stollenwerk, Jochen; Loosen, Peter

    2018-02-01

    The realization of the Digital Optical Twin (DOT), which is in short the digital representation of the physical state of an optical system, is particularly useful in the context of an automated assembly process of optical systems. During the assembly process, the physical system status of the optical system is continuously measured and compared with the digital model. In case of deviations between physical state and the digital model, the latter one is adapted to match the physical state. To reach the goal described above, in a first step measurement/characterization technologies concerning their suitability to generate a precise digital twin of an existing optical system have to be identified and evaluated. This paper gives an overview of possible characterization methods and, finally, shows first results of evaluated, compared methods (e.g. spot-radius, MTF, Zernike-polynomials), to create a DOT. The focus initially lies on the unequivocalness of the optimization results as well as on the computational time required for the optimization to reach the characterized system state. Possible sources of error are the measurement accuracy (to characterize the system) , execution time of the measurement, time needed to map the digital to the physical world (optimization step) as well as interface possibilities to integrate the measurement tool into an assembly cell. Moreover, it is to be discussed whether the used measurement methods are suitable for a `seamless' integration into an assembly cell.

  17. Measurements of Loma Linda proton therapy gantry dipoles

    International Nuclear Information System (INIS)

    Glass, H.D.; Mazur, P.O.; Sim, J.W.

    1993-01-01

    The authors describe the procedures used by the Fermilab Magnet Test Facility (MTF) to perform tests of dipoles to be installed in the beam lines of the Loma Linda Univ. Medical Center Proton Therapy Facility. The dipoles were manufactured in two styles, one style having a 45 degrees bending angle and the other a 135 degrees bending angle. The tests included magnetic field measurements using a Hall probe and the measurement of coil temperatures, voltages, and water flow rates. The probe was mounted on a movable cart which could be wheeled along the magnet beam pipe; they mounted extensions onto each end of the beam pipe to allow for the probe to measure the magnet end fields. The probe was also mounted at varying transverse positions on the cart to allow for field shape measurements, from which body quadrupole and sextupole coefficients were determined. A longitudinal sampling of the field down the entire length of the magnet allowed the authors to measure the total integrated field of each magnet. Hall probe measurements were controlled by a C program running on a Unix workstation

  18. Measurements of Loma Linda proton therapy gantry dipoles

    International Nuclear Information System (INIS)

    Glass, H.D.; Mazur, P.O.; Sim, J.W.

    1993-07-01

    We describe the procedures used by the Fermilab Magnet Test Facility (MTF) to perform tests of dipoles to be installed in the beam lines of the Loma Linda University Medical Center Proton Therapy Facility. The dipoles were manufactured in two styles, one style having a 45 degree bending angle and the other a 135 degree bending angle. The tests included magnetic field measurements using a Hall probe and the measurement of coil temperatures, voltages, and water flow rates. The probe was mounted on a movable cart which could be wheeled along the magnet beam pipe; we mounted extensions onto each end of the beam pipe to allow for the probe to measure the magnet end fields. The probe was also mounted at varying transverse positions on the cart to allow for field shape measurements, from which body quadrupole and sextupole coefficients were determined. A longitudinal sampling of the field down the entire length of the magnet allowed us to measure the total integrated field of each magnet. Hall probe measurements were controlled by a C program running on a Unix workstation

  19. Technical Note: Measuring contrast- and noise-dependent spatial resolution of an iterative reconstruction method in CT using ensemble averaging

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Lifeng, E-mail: yu.lifeng@mayo.edu; Vrieze, Thomas J.; Leng, Shuai; Fletcher, Joel G.; McCollough, Cynthia H. [Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2015-05-15

    Purpose: The spatial resolution of iterative reconstruction (IR) in computed tomography (CT) is contrast- and noise-dependent because of the nonlinear regularization. Due to the severe noise contamination, it is challenging to perform precise spatial-resolution measurements at very low-contrast levels. The purpose of this study was to measure the spatial resolution of a commercially available IR method using ensemble-averaged images acquired from repeated scans. Methods: A low-contrast phantom containing three rods (7, 14, and 21 HU below background) was scanned on a 128-slice CT scanner at three dose levels (CTDI{sub vol} = 16, 8, and 4 mGy). Images were reconstructed using two filtered-backprojection (FBP) kernels (B40 and B20) and a commercial IR method (sinogram affirmed iterative reconstruction, SAFIRE, Siemens Healthcare) with two strength settings (I40-3 and I40-5). The same scan was repeated 100 times at each dose level. The modulation transfer function (MTF) was calculated based on the edge profile measured on the ensemble-averaged images. Results: The spatial resolution of the two FBP kernels, B40 and B20, remained relatively constant across contrast and dose levels. However, the spatial resolution of the two IR kernels degraded relative to FBP as contrast or dose level decreased. For a given dose level at 16 mGy, the MTF{sub 50%} value normalized to the B40 kernel decreased from 98.4% at 21 HU to 88.5% at 7 HU for I40-3 and from 97.6% to 82.1% for I40-5. At 21 HU, the relative MTF{sub 50%} value decreased from 98.4% at 16 mGy to 90.7% at 4 mGy for I40-3 and from 97.6% to 85.6% for I40-5. Conclusions: A simple technique using ensemble averaging from repeated CT scans can be used to measure the spatial resolution of IR techniques in CT at very low contrast levels. The evaluated IR method degraded the spatial resolution at low contrast and high noise levels.

  20. The information spectrum as a measure of radiographic image quality and system performance

    International Nuclear Information System (INIS)

    Kanamori, H.; Matsumoto, M.

    1984-01-01

    The spectrum (spatial-frequency component) of the information capacity of a radiograph, here called the information spectrum, is offered as a measure of image quality and system performance. The information spectrum is a much more practical expression than information capacity by itself: it combines synthetically the contrast, the latitude, the sharpness and the granularity, and is expressed as a function of spatial frequency. The information spectrum can be readily calculated by using the dynamic density range and the MTF and noise Wiener spectrum at medium density range. A practical example is given. The appropriate system for each object can be selected by comparing the information spectral values of various imaging systems at the significant spatial frequency range predetermined for each object. (author)

  1. Early experience in the use of quantitative image quality measurements for the quality assurance of full field digital mammography x-ray systems

    International Nuclear Information System (INIS)

    Marshall, N W

    2007-01-01

    Quantitative image quality results in the form of the modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE) are presented for nine full field digital mammography (FFDM) systems. These parameters are routinely measured as part of the quality assurance (QA) programme for the seven FFDM units covered by our centre. Just one additional image is required compared to the standard FFDM protocol; this is the image of an edge, from which the MTF is calculated. A variance image is formed from one of the flood images used to measure the detector response and this provides useful information on the condition of the detector with respect to artefacts. Finally, the NNPS is calculated from the flood image acquired at a target detector air kerma (DAK) of 100 μGy. DQE is then estimated from these data; however, no correction is currently made for effects of detector cover transmission on DQE. The coefficient of variation (cov) of the 50% point of the MTF for five successive MTF results was 1%, while the cov for the 50% MTF point for an a-Se system over a period of 17 months was approximately 3%. For four a-Se based systems, the cov for the NNPS at 1 mm -1 for a target DAK of 100 μGy was approximately 4%; the same result was found for four CsI based FFDM units. With regard to the stability of NNPS over time, the cov for four NNPS results acquired over a period of 12 months was also approximately 4%. The effect of acquisition geometry on NNPS was also assessed for a CsI based system. NNPS data acquired with the antiscatter grid in place showed increased noise at low spatial frequency; this effect was more severe as DAK increased. DQE results for the three detector types (a-Se, CsI and CR) are presented as a function of DAK. Some reduction in DQE was found for both the a-Se and CsI based systems at a target DAK of 12.5 μGy when compared to DQE data acquired at 100 μGy. For the CsI based systems, DQE at 1 mm -1 fell from 0

  2. Development and application of programs to measure modulation transfer function, noise power spectrum and detective quantum efficiency.

    Science.gov (United States)

    Padgett, R; Kotre, C J

    2005-01-01

    This project aimed to produce programs to calculate the modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) of digital X-ray systems, given a suitable digital image. The MTF was calculated using the edge technique and the NPS was calculated from a flat field image. Both programs require a suitably edited DICOM image as input. The DQE was then calculated from the output of MTF and NPS programs. This required data external to the DQE program to estimate the number of quanta per mm2 in the beam which formed the NPS image. All three programs run independent of each other on a PC and require no special software to be installed. Results for MTF, NPS and DQE for a Philips AC3 CR system are presented. In addition, the results for MTF from a Siemens Duo CT scanner with a specially designed PTFE edge are also shown.

  3. Atmospheric Ice Nucleating Particle measurements at the high mountain observatory Mt. Cimone (2165 m a.s.l., Italy)

    Science.gov (United States)

    Rinaldi, M.; Santachiara, G.; Nicosia, A.; Piazza, M.; Decesari, S.; Gilardoni, S.; Paglione, M.; Cristofanelli, P.; Marinoni, A.; Bonasoni, P.; Belosi, F.

    2017-12-01

    Measurement campaigns at the high mountain Observatory Mt. Cimone (CMN; 2165 m a.s.l.) were performed during May 2014 and October 2015. The concentration of Ice Nucleating Particles (INPs) were measured offline with a dynamic filter processing chamber (DFPC), in the deposition and condensation mode, after collecting PM1 and PM10 aerosol samples. Presented INP data are the first ever published for a high mountain site in the Mediterranean basin. During the May campaign, parallel INP measurements were also carried out at San Pietro Capofiume (SPC), a low altitude rural background area within the Po Valley basin, by the same offline technique. The average INPPM10 concentration at CMN was 86 m-3 (saturation ratio Sw = 1.01; T = -18 °C) during the May 2014 campaign, while it was 171 m-3 at SPC, in the same period. A lower average INPPM10 concentration was observed at CMN during October 2015 (43 m-3). A significantly higher activated fraction (AF) characterized the October 2015 campaign, suggesting that the seasonal changes in the aerosol sources have an impact on the INP efficiency of the aerosol at CMN. Super-micrometer INP contributed for ∼30% of total INP in the May 2014 campaign, at both sites, and for ∼70% in the October 2015 campaign, showing the importance of coarse particles in the INP population. The analysis of meteorological parameters, gaseous tracers concentrations and backwards trajectories suggests that the INP population at CMN is contributed by transport processes occurring at diverse spatial scales, from the local to the synoptic scale. During the Saharan Dust transport Event observed in May 2014, a reduction of the AF was observed, suggesting, for this case, a limited ice nucleating activity for Saharan dust particles. This may be due to physico-chemical aging of the Saharan dust particles during transport or to the relatively high activation temperature at which the experiments were performed in this study.

  4. Development and application of an automatic system for measuring the laser camera

    International Nuclear Information System (INIS)

    Feng Shuli; Peng Mingchen; Li Kuncheng

    2004-01-01

    Objective: To provide an automatic system for measuring imaging quality of laser camera, and to make an automatic measurement and analysis system. Methods: On the special imaging workstation (SGI 540), the procedure was written by using Matlab language. An automatic measurement and analysis system of imaging quality for laser camera was developed and made according to the imaging quality measurement standard of laser camera of International Engineer Commission (IEC). The measurement system used the theories of digital signal processing, and was based on the characteristics of digital images, as well as put the automatic measurement and analysis of laser camera into practice by the affiliated sample pictures of the laser camera. Results: All the parameters of imaging quality of laser camera, including H-D and MTF curve, low and middle and high resolution of optical density, all kinds of geometry distort, maximum and minimum density, as well as the dynamic range of gray scale, could be measured by this system. The system was applied for measuring the laser cameras in 20 hospitals in Beijing. The measuring results showed that the system could provide objective and quantitative data, and could accurately evaluate the imaging quality of laser camera, as well as correct the results made by manual measurement based on the affiliated sample pictures of the laser camera. Conclusion: The automatic measuring system of laser camera is an effective and objective tool for testing the quality of the laser camera, and the system makes a foundation for the future research

  5. Experimental measurement of a high resolution CMOS detector coupled to CsI scintillators under X-ray radiation

    International Nuclear Information System (INIS)

    Michail, C.; Valais, I.; Seferis, I.; Kalyvas, N.; Fountos, G.; Kandarakis, I.

    2015-01-01

    The purpose of the present study was to assess the information content of structured CsI:Tl scintillating screens, specially treated to be compatible to a CMOS digital imaging optical sensor, in terms of the information capacity (IC), based on Shannon's mathematical communication theory. IC was assessed after the experimental determination of the Modulation Transfer Function (MTF) and the Normalized Noise Power Spectrum (NNPS) in the mammography and general radiography energy range. The CMOS sensor was coupled to three columnar CsI:Tl scintillator screens obtained from the same manufacturer with thicknesses of 130, 140 and 170 μm respectively, which were placed in direct contact with the optical sensor. The MTF was measured using the slanted-edge method while NNPS was determined by 2D Fourier transforming of uniformly exposed images. Both parameters were assessed by irradiation under the mammographic W/Rh (130, 140 and 170 μm CsI screens) and the RQA-5 (140 and 170 μm CsI screens) (IEC 62220-1) beam qualities. The detector response function was linear for the exposure range under investigation. At 70 kVp, under the RQA-5 conditions IC values were found to range between 2229 and 2340 bits/mm 2 . At 28 kVp the corresponding IC values were found to range between 2262 and 2968 bits/mm 2 . The information content of CsI:Tl scintillating screens in combination to the high resolution CMOS sensor, investigated in the present study, where found optimized for use in digital mammography imaging systems. - Highlights: • Three structured CsI:Tl screens (130,140 & 170 um) were coupled to a CMOS sensor. • MTF of the CsI/CMOS was higher than GOS:Tb and CsI based digital imaging systems. • IC of CsI:Tl/CMOS was found optimized for use in digital mammography systems

  6. Quality control measurements for digital x-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, N W [Department of Radiology, University Hospitals Leuven, 49 Herenstraat, 3000 Leuven (Belgium); Mackenzie, A [National Co-ordinating Centre for the Physics of Mammography, Medical Physics, Level B, St Luke' s Wing, The Royal Surrey County Hospital NHS Trust, Egerton Road, Guildford, GU2 7XX (United Kingdom); Honey, I D, E-mail: nicholas.marshall@uz.kuleuven.ac.be [Department of Medical Physics, Floor 3, Henriette Raphael House, Guy' s and St Thomas' Hospital, London, SE1 9RT (United Kingdom)

    2011-02-21

    This paper describes a digital radiography (DR) quality control protocol for DR detectors from the forthcoming report from the Institute of Physics and Engineering in Medicine (IPEM). The protocol was applied to a group of six identical caesium iodide (CsI) digital x-ray detectors to assess reproducibility of methods, while four further detectors were assessed to examine the wider applicability. Twelve images with minimal spatial frequency processing are required, from which the detector response, lag, modulation transfer function (MTF), normalized noise power spectrum (NNPS) and threshold contrast-detail (c-d) detectability are calculated. The x-ray spectrum used was 70 kV and 1 mm added copper filtration, with a target detector air kerma of 2.5 {mu}Gy for the NNPS and c-d results. In order to compare detector performance with previous imaging technology, c-d data from four screen/film systems were also acquired, at a target optical density of 1.5 and an average detector air kerma of 2.56 {mu}Gy. The DR detector images were typically acquired in 20 min, with a further 45 min required for image transfer and analysis. The average spatial frequency for the 50% point of the MTF for six identical detectors was 1.29 mm{sup -1} {+-} 0.05 (3.9% coefficient of variation (cov)). The air kerma set for the six systems was 2.57 {mu}Gy {+-} 0.13 (5.0% cov) and the NNPS at this air kerma was 1.42 x 10{sup -5} mm{sup 2} (6.5% cov). The detective quantum efficiency (DQE) measured for the six identical detectors was 0.60 at 0.5 mm{sup -1}, with a maximum cov of 10% at 2.9 mm{sup -1}, while the average DQE was 0.56 at 0.5 mm{sup -1} for three CsI detectors from three different manufacturers. Comparable c-d performance was found for these detectors (5.9% cov) with an average threshold contrast of 0.46% for 11 mm circular discs. The average threshold contrast for the S/F systems was 0.70% at 11 mm, indicating superior imaging performance for the digital systems. The protocol was found

  7. X-ray tube focal spot sizes: comprehensive studies of their measurement and effect of measured size in angiography

    International Nuclear Information System (INIS)

    Doi, K.; Loo, L.N.; Chan, H.P.

    1982-01-01

    Thirty-two focal spot sizes of four x-ray tubes were measured by the pinhole, star pattern, slit, and root-mean-square (RMS) methods under various exposure conditions. The modulation transfer functions (MTFs) and line spread functions (LSFs) were also determined. The star pattern focal spot sizes agreed with the effective sizes calculated from the frequencies at the first minimum of the MTF within 0.04 mm for large focal spots and within 0.01 mm for small focal spots. The focal spot size determined by the slit method was approximately equal to the width of the LSF at the cutoff level of 0.15 +/- 0.06 of the peak value. The RMS method provided the best correlation between the measured focal spot sizes and the corresponding image distributions of blood vessels. The pinhole and slit methods tended to overestimate the focal spot size, but the star pattern method tended to underestimate it. For approximately 90% of the focal spots, the average of the star and slit (or pinhole) focal spot sizes agreed with the RMS focal spot size within +/- 0.1 mm

  8. Using a Two-Step Method to Measure Transgender Identity in Latin America/the Caribbean, Portugal, and Spain

    Science.gov (United States)

    Reisner, Sari L.; Biello, Katie; Rosenberger, Joshua G.; Austin, S. Bryn; Haneuse, Sebastien; Perez-Brumer, Amaya; Novak, David S.; Mimiaga, Matthew J.

    2014-01-01

    Few comparative data are available internationally to examine health differences by transgender identity. A barrier to monitoring the health and well-being of transgender people is the lack of inclusion of measures to assess natal sex/gender identity status in surveys. Data were from a cross-sectional anonymous online survey of members (n > 36,000) of a sexual networking website targeting men who have sex with men in Spanish- and Portuguese-speaking countries/ territories in Latin America/the Caribbean, Portugal, and Spain. Natal sex/gender identity status was assessed using a two-step method (Step 1: assigned birth sex, Step 2: current gender identity). Male-to-female (MTF) and female-to-male (FTM) participants were compared to non-transgender males in age-adjusted regression models on socioeconomic status (SES) (education, income, sex work), masculine gender conformity, psychological health and well-being (lifetime suicidality, past-week depressive distress, positive self-worth, general self-rated health, gender related stressors), and sexual health (HIV-infection, past-year STIs, past-3 month unprotected anal or vaginal sex). The two-step method identified 190 transgender participants (0.54%; 158 MTF, 32 FTM). Of the 12 health-related variables, six showed significant differences between the three groups: SES, masculine gender conformity, lifetime suicidality, depressive distress, positive self-worth, and past-year genital herpes. A two-step approach is recommended for health surveillance efforts to assess natal sex/gender identity status. Cognitive testing to formally validate assigned birth sex and current gender identity survey items in Spanish and Portuguese is encouraged. PMID:25030120

  9. What quantum measurements measure

    Science.gov (United States)

    Griffiths, Robert B.

    2017-09-01

    A solution to the second measurement problem, determining what prior microscopic properties can be inferred from measurement outcomes ("pointer positions"), is worked out for projective and generalized (POVM) measurements, using consistent histories. The result supports the idea that equipment properly designed and calibrated reveals the properties it was designed to measure. Applications include Einstein's hemisphere and Wheeler's delayed choice paradoxes, and a method for analyzing weak measurements without recourse to weak values. Quantum measurements are noncontextual in the original sense employed by Bell and Mermin: if [A ,B ]=[A ,C ]=0 ,[B ,C ]≠0 , the outcome of an A measurement does not depend on whether it is measured with B or with C . An application to Bohm's model of the Einstein-Podolsky-Rosen situation suggests that a faulty understanding of quantum measurements is at the root of this paradox.

  10. Measurement of modulation transfer function in z-axis for multi-slice spiral CT using the micro-disk method. Comparison with the bead method and examination of geometric influence

    International Nuclear Information System (INIS)

    Hara, Takanori

    2003-01-01

    Many methods of measuring the section-sensitive profile (SSP) of computed tomography (CT) by the input of a delta function have been reported. In Japan, the bead method is used as a common measurement because of the high flexibility of the multi-purpose method. However, the intensity of the response of the bead method tends to decline, creating a relatively large error in the base of SSPs. A problem is considered to be the accuracy of measurement in evaluating spatial resolution along the z-axis in multi-slice spiral/helical CT (MSCT). We therefore evaluated the modulation transfer function (MTF) by conducting research with the micro-disk method (100 μm thickness and 1.0 mmφ diameter) and the bead method (1.0 mmφ diameter) for the same input width. Moreover, in the micro-disk method, we also examined alignment, circular region of interest (ROI), and the energy characteristic. Our comparison of MTFs obtained by the micro-disk method and the bead method showed that the former resulted in a higher value and lower standard deviation. The difference was significant at p<0.01. Measurement using the micro-disk method did not show significant differences in terms of alignment and ROIs. Moreover, the energy characteristic was not indicated. This research demonstrated that the accuracy of MTF measurement with the micro-disk method was greater than that with the bead method, and it was found that there was no influence on the actual measurement level of the geometric structure with the micro-disk method. (author)

  11. Cascaded systems analysis of charge sharing in cadmium telluride photon-counting x-ray detectors.

    Science.gov (United States)

    Tanguay, Jesse; Cunningham, Ian A

    2018-05-01

    Single-photon-counting (SPC) and spectroscopic x-ray detectors are under development in academic and industry laboratories for medical imaging applications. The spatial resolution of SPC and spectroscopic x-ray detectors is an important design criterion. The purpose of this article was to extend the cascaded systems approach to include a description of the spatial resolution of SPC and spectroscopic x-ray imaging detectors. A cascaded systems approach was used to model reabsorption of characteristic x rays, Coulomb repulsion, and diffusion in SPC and spectroscopic x-ray detectors. In addition to reabsorption, diffusion, and Coulomb repulsion, the model accounted for x-ray conversion to electron-hole (e-h) pairs, integration of e-h pairs in detector elements, electronic noise, and energy thresholding. The probability density function (PDF) describing the number of e-h pairs was propagated through each stage of the model and was used to derive new theoretical expressions for the large-area gain and modulation transfer function (MTF) of CdTe SPC x-ray detectors, and the energy bin sensitivity functions and MTFs of CdTe spectroscopic detectors. Theoretical predictions were compared with the results of MATLAB-based Monte Carlo (MC) simulations and published data. Comparisons were also made with the MTF of energy-integrating systems. Under general radiographic conditions, reabsorption, diffusion, and Coulomb repulsion together artificially inflate count rates by 20% to 50%. For thicker converters (e.g. 1000 μm) and larger detector elements (e.g. 500 μm pixel pitch) these processes result in modest inflation (i.e. ∼10%) in apparent count rates. Our theoretical and MC analyses predict that SPC MTFs will be degraded relative to those of energy-integrating systems for fluoroscopic, general radiographic, and CT imaging conditions. In most cases, this degradation is modest (i.e., ∼10% at the Nyquist frequency). However, for thicker converters, the SPC MTF can be degraded

  12. Correlation between the physical performances measured from detectors and the diagnostic image quality in digital mammography

    International Nuclear Information System (INIS)

    Perez-Ponce, H.

    2009-05-01

    In digital mammography two approaches exist to estimate image quality. In the first approach, human observer assesses the lesion detection in mammograms. Unfortunately, such quality assessment is subject to interobserver variability, and requires a large amount of time and human resources. In the second approach, objective and human-independent parameters relating to image spatial resolution and noise (MTF and NPS) are used to evaluate digital detector performance; even if these parameters are objective, they are not directly related to lesion detection. A method leading to image quality assessment which is both human independent, and directly related to lesion detection is very important for the optimal use of mammographic units. This Ph.D thesis presents the steps towards such a method: the computation of realistic virtual images using an 'X ray source/digital detector' model taking into account the physical parameters of the detector (spatial resolution and noise measurements) measured under clinical conditions. From results obtained in this work, we have contributed to establish the link between the physical characteristics of detectors and the clinical quality of the image for usual exposition conditions. Furthermore, we suggest the use of our model for the creation of virtual images, in order to rapidly determine the optimal conditions in mammography, which usually is a long and tedious experimental process. This is an essential aspect to be taken into account for radioprotection of patients, especially in the context of organized mass screening of breast cancer. (author)

  13. Modeling Change in Large-Scale Longitudinal Studies of Educational Growth: Four Decades of Contributions to the Assessment of Educational Growth. ETC R&D Scientific and Policy Contributions Series. ETS SPC-12-01. Research Report No. RR-12-04

    Science.gov (United States)

    Rock, Donald A.

    2012-01-01

    This paper provides a history of ETS's role in developing assessment instruments and psychometric procedures for measuring change in large-scale national assessments funded by the Longitudinal Studies branch of the National Center for Education Statistics. It documents the innovations developed during more than 30 years of working with…

  14. Modeling Change in Large-Scale Longitudinal Studies of Educational Growth: Four Decades of Contributions to the Assessment of Educational Growth. Research Report. ETS RR-12-04. ETS R&D Scientific and Policy Contributions Series. ETS SPC-12-01

    Science.gov (United States)

    Rock, Donald A.

    2012-01-01

    This paper provides a history of ETS's role in developing assessment instruments and psychometric procedures for measuring change in large-scale national assessments funded by the Longitudinal Studies branch of the National Center for Education Statistics. It documents the innovations developed during more than 30 years of working with…

  15. Mobile measurement setup according to IEC 62220-1-2 for DQE determination on digital mammography systems

    Science.gov (United States)

    Greiter, Matthias B.; Hoeschen, Christoph

    2010-04-01

    The international standard IEC 62220-1-2 defines the measurement procedure for determination of the detective quantum efficiency (DQE) of digital x-ray imaging devices used in mammography. A mobile setup complying to this standard and adaptable to most current systems was constructed in the Helmholtz Zentrum München to allow for an objective technical comparison of current full field digital mammography units employed in mammography screening in Germany. This article demonstrates the setup's capabilities with a focus on the measurement uncertainties of all quantities contributing to DQE measurements. Evaluation of uncertainties encompasses results from measurements on a Sectra Microdose Mammography in clinical use, as well as on a prototype of a Fujifilm Amulet system at various radiation qualities. Both systems have a high spatial resolution of 50 μm × 50 μm. The modulation transfer function (MTF), noise power spectrum (NPS) and DQE of the Sectra MDM are presented in comparison to results previously published by other authors.

  16. Intravaginal administration of metformin hydrochloride loaded cationic niosomes amalgamated with thermosensitive gel for the treatment of polycystic ovary syndrome: In vitro and in vivo studies.

    Science.gov (United States)

    Saini, Neetu; Sodhi, Rupinder Kaur; Bajaj, Lotika; Pandey, Ravi Shankar; Jain, Upendra Kumar; Katare, Om Prakash; Madan, Jitender

    2016-08-01

    Metformin hydrochloride (MTF-HCl) is extensively recommended by physicians for the treatment of polycystic ovary syndrome (PCOS). Mechanistically, MTF-HCl activates AMP-dependent kinase-α (AMPK-α) pathway to decrease the glucose production, enhances fatty acid oxidation and elevates the uptake of glucose in tissues. However, despite favourable physicochemical properties, oral administration of MTF-HCl is associated with impaired bioavailability (50-60%), lactic-acidosis and frequent dosing (500mg 2-3 times a day) in PCOS that ultimately influence the patient compliance. Therefore, in present investigation, MTF-HCl loaded unmodified and cationic small unilamellar niosomes were separately amalgamated with thermosensitive gel (MTF-HCl-SUNs-Gel and MTF-HCl-C-SUNs-Gel) for the treatment of PCOS through vaginal route of administration. MTF-HCl-SUNs and MTF-HCl-C-SUNs were separately prepared by reverse phase evaporation method. The nanovesicle size and zeta-potential of MTF-HCl-C-SUNs were measured to be 210.3±14.8-nm (Ptreatment of PCOS rats under scheduled dose-dosage regimen with oral MTF-HCl solution, intravaginal MTF-HCl-SUNs-Gel and intravaginal MTF-HCl-C-SUNs-gel exhibited remarkable alterations, recruitment and development of normal follicles in addition to normalization of level of various hormones in PCOS. In conclusion, MTF-C-SUNs-Gel has paved the way for developing intravaginal dosage form of MTF-HCl for the treatment of PCOS. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Fuzzy Gauge Capability (Cg and Cgk) through Buckley Approach

    OpenAIRE

    Seyed Habib A. Rahmati; Mohsen Sadegh Amalnick

    2015-01-01

    Different terms of the Statistical Process Control (SPC) has sketch in the fuzzy environment. However, Measurement System Analysis (MSA), as a main branch of the SPC, is rarely investigated in fuzzy area. This procedure assesses the suitability of the data to be used in later stages or decisions of the SPC. Therefore, this research focuses on some important measures of MSA and through a new method introduces the measures in fuzzy environment. In this method, which works b...

  18. Entropy as a measure of the performance of phosphor materials used in medical imaging radiation detectors

    International Nuclear Information System (INIS)

    Cavouras, D.; Kandarakis, I.; Maris, T.; Panayiotakis, G.S.; Nomicos, C.D.

    2001-01-01

    In information theory, entropy expresses the information gain obtained after detection of a signal concerning the state of a parameter of interest. In this study, entropy has been expressed in terms of physical quantities (emitted optical fluence and MTF) related to the imaging performance of phosphor materials, which are employed in medical imaging radiation detectors. Four phosphor materials, used in the form of laboratory-prepared fluorescent layers (screens), were compared on the basis of their entropy performance. Measurements were performed using 30- and 80-kVp X-ray beams often employed in X-ray imaging. Results showed that phosphor materials with high density and effective atomic number exhibit high entropy performance, especially at the higher X-ray tube voltage of 80 kVp. Entropy values are also affected by the type of activator, which determines the intrinsic X-ray-to-light conversion efficiency, and the spectrum of emitted light. The proximity of the incident X-ray quanta energy to the energy of the K-shell threshold for photoelectric absorption is an additional important factor which increases entropy. This effect was more apparent in the performance of yttrium-based phosphors at the lower voltage of 30 kVp. (orig.)

  19. CT head-scan dosimetry in an anthropomorphic phantom and associated measurement of ACR accreditation-phantom imaging metrics under clinically representative scan conditions

    Energy Technology Data Exchange (ETDEWEB)

    Brunner, Claudia C.; Stern, Stanley H.; Chakrabarti, Kish [U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, Maryland 20993 (United States); Minniti, Ronaldo [National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899 (United States); Parry, Marie I. [Walter Reed National Military Medical Center, 8901 Rockville Pike, Bethesda, Maryland 20889 (United States); Skopec, Marlene [National Institutes of Health, 9000 Rockville Pike, Bethesda, Maryland 20892 (United States)

    2013-08-15

    Purpose: To measure radiation absorbed dose and its distribution in an anthropomorphic head phantom under clinically representative scan conditions in three widely used computed tomography (CT) scanners, and to relate those dose values to metrics such as high-contrast resolution, noise, and contrast-to-noise ratio (CNR) in the American College of Radiology CT accreditation phantom.Methods: By inserting optically stimulated luminescence dosimeters (OSLDs) in the head of an anthropomorphic phantom specially developed for CT dosimetry (University of Florida, Gainesville), we measured dose with three commonly used scanners (GE Discovery CT750 HD, Siemens Definition, Philips Brilliance 64) at two different clinical sites (Walter Reed National Military Medical Center, National Institutes of Health). The scanners were set to operate with the same data-acquisition and image-reconstruction protocols as used clinically for typical head scans, respective of the practices of each facility for each scanner. We also analyzed images of the ACR CT accreditation phantom with the corresponding protocols. While the Siemens Definition and the Philips Brilliance protocols utilized only conventional, filtered back-projection (FBP) image-reconstruction methods, the GE Discovery also employed its particular version of an adaptive statistical iterative reconstruction (ASIR) algorithm that can be blended in desired proportions with the FBP algorithm. We did an objective image-metrics analysis evaluating the modulation transfer function (MTF), noise power spectrum (NPS), and CNR for images reconstructed with FBP. For images reconstructed with ASIR, we only analyzed the CNR, since MTF and NPS results are expected to depend on the object for iterative reconstruction algorithms.Results: The OSLD measurements showed that the Siemens Definition and the Philips Brilliance scanners (located at two different clinical facilities) yield average absorbed doses in tissue of 42.6 and 43.1 m

  20. Effectiveness of risk minimization measures for cabergoline-induced cardiac valve fibrosis in clinical practice in Italy.

    Science.gov (United States)

    Italiano, Domenico; Bianchini, Elisa; Ilardi, Maura; Cilia, Roberto; Pezzoli, Gianni; Zanettini, Renzo; Vacca, Laura; Stocchi, Fabrizio; Bramanti, Placido; Ciurleo, Rosella; Di Lorenzo, Giuseppe; Polimeni, Giovanni; de Luise, Cynthia; Ross, Douglas; Rijnbeek, Peter; Sturkenboom, Miriam; Trifirò, Gianluca

    2015-06-01

    On June 2008, the European Medicines Agency (EMA) introduced changes to the Summary of Product Characteristics (SPC) for cabergoline and pergolide, to reduce the risk of cardiac valvulopathy in users of these drugs. To assess the effectiveness of EMA recommendations in Italian clinical practice, we retrospectively reviewed medical charts of patients with degenerative Parkinsonism treated with cabergoline in three large Italian clinics between January 2006 and June 2012. The prevalence and the severity of cardiac valve regurgitation were assessed in patients who stopped cabergoline therapy prior to June 2008 or continued therapy after that date. In addition, the proportion of patients undergoing echocardiographic examination in each cohort was evaluated. A total of 61 patients were available for evaluation. The proportion of patients who underwent a baseline echocardiographic examination increased from 64 % in the period before the 2008 SPC changes to 71 % among those who continued treatment after that date. However, only 18 and 29 % of patients underwent at least two echocardiographic examinations during the pre-SPC and cross-SPC change period, respectively. No severe cardiac valve regurgitation was documented in any of the study patients using cabergoline either prior or after 26th June 2008. Our findings show that the 2008 changes to the SPC resulted in an increase in physicians' awareness of cabergoline-induced valvulopathy risk in Italy. However, only a small percentage of patients underwent serial echocardiography. Further efforts are needed to achieve better compliance with the prescribing guidelines for cabergoline treated patients in clinical practice.

  1. Importance measures

    International Nuclear Information System (INIS)

    Gomez Cobo, A.

    1997-01-01

    The presentation discusses the following: general concepts of importance measures; example fault tree, used to illustrate importance measures; Birnbaum's structural importance; criticality importance; Fussel-Vesely importance; upgrading function; risk achievement worth; risk reduction worth

  2. Formative (measurement)

    NARCIS (Netherlands)

    Fassott, G.; Henseler, Jörg; Cooper, C.; Lee, N.; Farrell, A.

    2015-01-01

    When using measurement models with multiple indicators, researchers need to decide about the epistemic relationship between the latent variable and its indicators. In this article, we describe the nature, the estimation, the characteristics, and the validity assessment of formative measurement

  3. Analysis of xanthines in beverages using a fully automated SPE-SPC-DAD hyphenated system

    Energy Technology Data Exchange (ETDEWEB)

    Medvedovici, A. [Bucarest Univ., Bucarest (Romania). Faculty of Chemistry, Dept. of Analytical Chemistry; David, F.; David, V.; Sandra, P. [Research Institute of Chromatography, Kortrijk (Belgium)

    2000-08-01

    Analysis of some xanthines (caffeine, theophylline and theobromine) in beverages has been achieved by a fully automated on-line Solid Phase Extraction - Supercritical Fluid Chromatography - Diode Array Detection (Spe - Sofc - Dad). Three adsorbents have been tested for the Spe procedure: octadecyl modified silicagel (ODS) and two types of styrene-divinylbenzen copolymer based materials, from which Porapack proved to be the most suitable adsorbent. Optimisation and correlation of both Spe and Sofc operational parameters are also discussed. By this technique, caffeine was determined in ice tea and Coca-Cola in a concentration of 0.15 ppm, theobromine - 1.5 ppb, and theophylline - 0.15 ppb. [Italian] Si e' realizzata l'analis di alcune xantine (caffeina, teofillina e teobromina) mediante un sistema, in linea, completamente automatizzato basato su Estrazione in Fase Solida - Cromatografia in Fase Supercritica - Rivelazione con Diode Array (Spe - Sfc - Dad). Per la procedura Spe sono stati valutati tre substrati: silice ottadecilica (ODS) e due tipi di materiali polimerici a base stirene-divinilbenzene, di cui, quello denominato PRP-1, e' risultato essere il piu' efficiente. Sono discusse sia l'ottimizzazione che la correlazione dei parametri operazionali per la Spe e la Sfc. Con questa tecnica sono state determinate, in te' ghiacciato e Coca-Cola, la caffeina, la teobromina e la teofillina alle concentrazini di 0.15, 1.5 e 0.15 ppm.

  4. Pengendalian Kualitas Produk Di Industri Garment Dengan Menggunakan Statistical Procces Control (SPC)

    OpenAIRE

    Rizal Rachman

    2017-01-01

    Abstrak Perusahaan memandang bahwa kualitas sebagai faktor kunci yang membawa keberhasilan dan standar mutu yang telah ditetapkan oleh buyer. Tujuan penelitian ini adalah untuk mengetahui tingkat kerusakan produk dalam batas pengendalian kualitas pada proses produksi pakaian jadi pada PT. Asia Penta Garment. Penelitian ini menggunakan metode statistical procces control. Data yang diambil dalam penelitian ini mengunakan data sekunder berupa laporan jumlah produksi dan kerusakan pakaian jad...

  5. Manufacturability: from design to SPC limits through "corner-lot" characterization

    Science.gov (United States)

    Hogan, Timothy J.; Baker, James C.; Wesneski, Lisa; Black, Robert S.; Rothenbury, Dave

    2005-01-01

    Texas Instruments" Digital Micro-mirror Device, is used in a wide variety of optical display applications ranging from fixed and portable projectors to high-definition television (HDTV) to digital cinema projection systems. A new DMD pixel architecture, called "FTP", was designed and qualified by Texas Instruments DLPTMTM Group in 2003 to meet increased performance objectives for brightness and contrast ratio. Coordination between design, test and fabrication groups was required to balance pixel performance requirements and manufacturing capability. "Corner Lot" designed experiments (DOE) were used to verify "fabrication space" available for the pixel design. The corner lot technique allows confirmation of manufacturability projections early in the design/qualification cycle. Through careful design and analysis of the corner-lot DOE, a balance of critical dimension (cd) "budgets" is possible so that specification and process control limits can be established that meet both customer and factory requirements. The application of corner-lot DOE is illustrated in a case history of the DMD "FTP" pixel. The process for balancing test parameter requirements with multiple critical dimension budgets is shown. MEMS/MOEMS device design and fabrication can use similar techniques to achieve agressive design-to-qualification goals.

  6. Effects of bundling on the properties of the SPC water model

    NARCIS (Netherlands)

    Fuhrmans, Marc; Sanders, Barbara P.; Marrink, Siewert-Jan; de Vries, Alex H.

    Simultaneous representation of molecules at an all-atom and coarse-grained level, as required by multiscaling molecular dynamics simulations, poses problems for the treatment of small molecules. If more than one of these molecules are mapped to a single coarse-grained interaction site, unrestricted

  7. Distribution of endotracheally instilled surfactant protein SP-C in lung-lavaged rabbits.

    NARCIS (Netherlands)

    Bambang Oetomo, Sidarto; de Leij, Louis; Curstedt, T; ter Haar, J G; Schoots, Coenraad; Wildevuur, Charles; Okken, Albert

    In lung-lavaged surfactant-deficient rabbits (n = 6) requiring artificial ventilation, porcine surfactant was instilled endotracheally. This resulted in improvement of lung function so that the animals could be weaned off artificial ventilation. The animals were killed 4 1/2 h after surfactant

  8. Measurement evaluation

    CERN Document Server

    Boros, A

    1990-01-01

    The information obtained about a measured object is called ``crude'' measurement information and must be related to the conditions under which the measurement took place. Using ``crude'' measurement information as a starting point, evaluation produces physically correctly interpreted data with their estimated (or corrected) error. Although a number of works deal with the evaluation of measurements, they either appeared a long time ago or serve essentially different aims. This book gives a comprehensive and current overview on the basic principles, aids, devices, and methods in the eval

  9. Development of Stand Alone Application Tool for Processing and Quality Measurement of Weld Imperfection Image Captured by μ-Focused Digital Radiography Using MATLAB- Based Graphical User Interface

    Directory of Open Access Journals (Sweden)

    PZ Nadila

    2012-12-01

    Full Text Available Digital radiography incresingly is being applied in the fabrication industry. Compared to film- based radiography, digitally radiographed images can be acquired with less time and fewer exposures. However, noises can simply occur on the digital image resulting in a low-quality result. Due to this and the system’s complexity, parameters’ sensitivity, and environmental effects, the results can be difficult to interpret, even for a radiographer. Therefore, the need of an application tool to improve and evaluate the image is becoming urgent. In this research, a user-friendly tool for image processing and image quality measurement was developed. The resulting tool contains important components needed by radiograph inspectors in analyzing defects and recording the results. This tool was written by using image processing and the graphical user interface development environment and compiler (GUIDE toolbox available in Matrix Laboratory (MATLAB R2008a. In image processing methods, contrast adjustment, and noise removal, edge detection was applied. In image quality measurement methods, mean square error (MSE, peak signal-to-noise ratio (PSNR, modulation transfer function (MTF, normalized signal-to-noise ratio (SNRnorm, sensitivity and unsharpness were used to measure the image quality. The graphical user interface (GUI wass then compiled to build a Windows, stand-alone application that enables this tool to be executed independently without the installation of MATLAB.

  10. Magnetized Target Fusion (MTF): A Low-Cost Fusion Development Path

    International Nuclear Information System (INIS)

    Lindemuth, I.R.; Siemon, R.E.; Kirkpatrick, R.C.; Reinovsky, R.E.

    1998-01-01

    Simple transport-based scaling laws are derived to show that a density and time regime intermediate between conventional magnetic confinement and conventional inertial confinement offers attractive reductions in system size and energy when compared to magnetic confinement and attractive reductions in heating power and intensity when compared to inertial confinement. This intermediate parameter space appears to be readily accessible by existing and near term pulsed power technologies. Hence, the technology of the Megagauss conference opens up an attractive path to controlled thermonuclear fusion

  11. The plasma formation stage in magnetic compression/magnetized target fusion (MAGO/MTF)

    International Nuclear Information System (INIS)

    Lindemuth, I.R.; Reinovsky, R.E.; Chrien, R.E.

    1996-01-01

    In early 1992, emerging governmental policy in the US and Russia began to encourage ''lab-to-lab'' interactions between the All- Russian Scientific Research Institute of Experimental Physics (VNIIEF) and the Los Alamos National Laboratory (LANL). As nuclear weapons stockpiles and design activities were being reduced, highly qualified scientists become for fundamental scientific research of interest to both nations. VNIIEF and LANL found a common interest in the technology and applications of magnetic flux compression, the technique for converting the chemical energy released by high-explosives into intense electrical pulses and intensely concentrated magnetic energy. Motivated originally to evaluate any possible defense applications of flux compression technology, the two teams worked independently for many years, essentially unaware of the others' accomplishments. But, an early US publication stimulated Soviet work, and the Soviets followed with a report of the achievement of 25 MG. During the cold war, a series of conferences on Megagauss Magnetic Field Generation and Related Topics became a forum for scientific exchange of ideas and accomplishments. Because of relationships established at the Megagauss conferences, VNIIEF and LANL were able to respond quickly to the initiatives of their respective governments. In late 1992, following the Megagauss VI conference, the two institutions agreed to combine resources to perform a series of experiments that essentially could not be performed by each institution independently. Beginning in September, 1993, the two institutions have performed eleven joint experimental campaigns, either at VNIIEF or at LANL. Megagauss- VII has become the first of the series to include papers with joint US and Russian authorship. In this paper, we review the joint LANL/VNIIEF experimental work that has relevance to a relatively unexplored approach to controlled thermonuclear fusion

  12. Progress in the Design of the Stabilized Liner Compressor for MTF/MIF Plasma Target Development

    Science.gov (United States)

    Frese, Sherry; Frese, Michael; Turchi, Peter; Gale, Don

    2016-10-01

    The Stabilized Liner Compressor (SLC) seeks to extend concepts for repetitive, rotationally stabilized, liquid-metal liners driven by free-pistons to much higher drive pressures (25 vs 5 kpsi) and faster implosion speeds (2000 vs 100 m/s) than previously demonstrated. Such extension is needed to enable experiments with magnetized-plasma targets presently offering sizes and lifetimes of 10's cm diam and 10's microsec. SLC represents the confluence of several difficult technologies, including pulsed high pressures, high-speed rotating machinery and alkali-metal (Na, NaK) handling. Solution of the two-dimensional, unsteady, compressible flow of a rotating liquid-metal liner requires advanced numerical techniques. We report the use of the 2-1/2 dimensional MHD code MACH2 to explore flow options, including magnetic flux compression, and to provide pulsed pressure distributions for mechanical design. Supported by ARPA-E ALPHA Program.

  13. Characterization of Request Sequences for List Accessing Problem and New Theoretical Results for MTF Algorithm

    OpenAIRE

    Mohanty, Rakesh; Sharma, Burle; Tripathy, Sasmita

    2011-01-01

    List Accessing Problem is a well studied research problem in the context of linear search. Input to the list accessing problem is an unsorted linear list of distinct elements along with a sequence of requests, where each request is an access operation on an element of the list. A list accessing algorithm reorganizes the list while processing a request sequence on the list in order to minimize the access cost. Move-To-Front algorithm has been proved to be the best performing list accessing onl...

  14. Flooding Hazards across Southern China and Prospective Sustainability Measures

    Directory of Open Access Journals (Sweden)

    Hai-Min Lyu

    2018-05-01

    Full Text Available The Yangtze River Basin and Huaihe River Basin in Southern China experienced severe floods 1998 and 2016. The reasons for the flooding hazards include the following two factors: hazardous weather conditions and degradation of the hydrological environment due to anthropogenic activities. This review work investigated the weather conditions based on recorded data, which showed that both 1998 and 2016 were in El Nino periods. Human activities include the degradations of rivers and lakes and the effects caused by the building of the Three Gorges Dam. In addition, the flooding in 2016 had a lower hazard scale than that in 1998 but resulted in larger economic losses than that of 1998. To mitigate urban waterlogging caused by flooding hazards, China proposed a new strategy named Spongy City (SPC in 2014. SPC promotes sustainable city development so that a city has the resilience to adapt to climate change, to mitigate the impacts of waterlogging caused by extreme rainfall events. The countermeasures used to tackle the SPC construction-related problems, such as local inundation, water resource shortage, storm water usage, and water pollution control, are proposed for city management to improve the environment.

  15. Quantum measurement

    CERN Document Server

    Busch, Paul; Pellonpää, Juha-Pekka; Ylinen, Kari

    2016-01-01

    This is a book about the Hilbert space formulation of quantum mechanics and its measurement theory. It contains a synopsis of what became of the Mathematical Foundations of Quantum Mechanics since von Neumann’s classic treatise with this title. Fundamental non-classical features of quantum mechanics—indeterminacy and incompatibility of observables, unavoidable measurement disturbance, entanglement, nonlocality—are explicated and analysed using the tools of operational quantum theory. The book is divided into four parts: 1. Mathematics provides a systematic exposition of the Hilbert space and operator theoretic tools and relevant measure and integration theory leading to the Naimark and Stinespring dilation theorems; 2. Elements develops the basic concepts of quantum mechanics and measurement theory with a focus on the notion of approximate joint measurability; 3. Realisations offers in-depth studies of the fundamental observables of quantum mechanics and some of their measurement implementations; and 4....

  16. Measurement Uncertainty

    Science.gov (United States)

    Koch, Michael

    Measurement uncertainty is one of the key issues in quality assurance. It became increasingly important for analytical chemistry laboratories with the accreditation to ISO/IEC 17025. The uncertainty of a measurement is the most important criterion for the decision whether a measurement result is fit for purpose. It also delivers help for the decision whether a specification limit is exceeded or not. Estimation of measurement uncertainty often is not trivial. Several strategies have been developed for this purpose that will shortly be described in this chapter. In addition the different possibilities to take into account the uncertainty in compliance assessment are explained.

  17. Evaluation of the modulation transfer function for computer tomography by using American Association Physics Medicine Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Won [Dept. of Radiology, Kyung Hee University Hospital at Gang-dong, Seoul (Korea, Republic of); Choi, Kwan Woo [Dept. of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Baekseok Culture University, Cheonan (Korea, Republic of); Jang, Seo Goo [Dept. of Medical Science, Soonchunhyang University, Asan (Korea, Republic of); Kwon, Kyung Tae [Dept. of Radiological Technology, Dongnam Health University, Suwon (Korea, Republic of); Son, Soon Yong [Dept. of Radiological Technology, Wonkwang Health Science University, Iksan (Korea, Republic of); Son, Jin Hyun; Min, Jung Whan [Dept. of Radiological Technology, Shingu University, Sungnam (Korea, Republic of)

    2016-06-15

    In clinical computed tomography (CT), regular quality assurance (QA) has been required. This study is to evaluate the MTF for analyzing the spatial resolution using AAPM phantom in CT exam. The dual source somatom definition flash (siemens healthcare, forchheim, Germany), the brilliance 64 (philips medical system Netherlands) and aquilion 64 (toshiba medical system, Japan) were used in this study. The quantitative evaluation was performed using the image J (wayne rasband national institutes of health, USA) and chart method which is measurement of modulation transfer function (MTF). In MTF evaluation, the spatial frequencies corresponding to the 50% MTF for the CT systems were 0.58, 0.28, and 0.59 mm-1, respectively and the 10% MTF for the CT systems were 1.63, 0.89, and 1.21 mm-1, respectively. This study could evaluate the characteristic of spatial resolution of MTF using chart method, suggesting the quantitative evaluation method using the data.

  18. Standards Performance Continuum: Development and Validation of a Measure of Effective Pedagogy.

    Science.gov (United States)

    Doherty, R. William; Hilberg, R. Soleste; Epaloose, Georgia; Tharp, Roland G.

    2002-01-01

    Describes the development and validation of the Standards Performance Continuum (SPC) for assessing teacher performance of the Standards for Effective Pedagogy. Three studies involving Florida, California, and New Mexico public school teachers provided evidence of inter-rater reliability, concurrent validity, and criterion-related validity…

  19. Measuring Colour

    CERN Document Server

    Hunt, R W G

    2011-01-01

    The classic authority on colour measurement now fully revised and updated with the latest CIE recommendations The measurement of colour is of major importance in many commercial applications, such as the textile, paint, and foodstuff industries; as well as having a significant role in the lighting, paper, printing, cosmetic, plastics, glass, chemical, photographic, television, transport, and communication industries. Building upon the success of earlier editions, the 4th edition of Measuring Colour has been updated throughout with new chapters on colour rendering by light sources; colorimetry

  20. Mechanical measurements

    CERN Document Server

    Venkateshan, S P

    2015-01-01

    The first edition of this book was co-published by Ane Books India, and CRC Press in 2008. This second edition is an enlarged version of the web course developed by the author at IIT Madras, and also a modified and augmented version of the earlier book.  Major additions/modifications presented are in the treatment of errors in measurement, temperature measurement, measurement of thermo-physical properties, and data manipulation. Many new worked examples have been introduced in this new and updated second edition. 

  1. Horizon measures

    KAUST Repository

    Zhang, Eugene

    2016-11-28

    In this paper we seek to answer the following question: where do contour lines and visible contour lines (silhouette) tend to occur in a 3D surface. Our study leads to two novel shape descriptors, the horizon measure and the visible horizon measure, which we apply to the visualization of 3D shapes including archeological artifacts. In addition to introducing the shape descriptors, we also provide a closed-form formula for the horizon measure based on classical spherical geometry. To compute the visible horizon measure, which depends on the exact computation of the surface visibility function, we instead of provide an image-based approach which can process a model with high complexity within a few minutes.

  2. Lifetime measurements

    International Nuclear Information System (INIS)

    Poletti, A.R.

    1976-01-01

    Recent developments in experimental methods of measuring the lifetimes of excited nuclear states is reviewed in three main areas. (a) Doppler Shift Attenuation Measurements (DSAM) Times: 10 -14 - 10 -11 sec.; (b) Recoil Distance Measurements (RDM) Times: 10 -9 - 10 -12 sec.; (c) Direct Electronic Timing Times: down to 10 -10 sec.; A measurement of an excited state lifetime can answer a large number of different questions. Two examples are discussed: (a) The determination of the lifetime of an isomeric transition in 93 Tc and its use in determining an upper limit for the magnitude of the parity non-conserving matrix element - /Hsub(PN)/17/2 + >. (b) The dependence of the strength of M2 transitions on isospin in nuclei in the 1dsub(3/2) -1fsub(7/2) region. (author)

  3. MEASURING CIRCUIT

    Science.gov (United States)

    Mahoney, J.R.

    1963-01-29

    A measuring and balancing arrangement for mass spectrometers permits the ready determination of isotopic ratios and mole and weight percentages by employing a selection of amplifier input resistors to vary sensitivity in a bridge arrangement. (AEC)

  4. Measuring colour

    National Research Council Canada - National Science Library

    Hunt, R. W. G; Pointer, Michael, Ph. D

    2011-01-01

    ... industries.Building upon the success of earlier editions, the 4th edition of [start italics]Measuring Colour[end italics] has been updated throughout with new chapters on colour rendering by light sources...

  5. Diversity Measures

    Directory of Open Access Journals (Sweden)

    MSc. Mentor Ademaj

    2012-06-01

    Full Text Available Diversity measures are a type of non-criminal measures foreseen in the Chapter IV of the Code of Juvenile Justice, which may be imposed on juvenile perpetrators of criminal acts. These measures can be applied in cases of minor offenses, for which is foreseen the criminal sanction with a fine or imprisonment up to three years or for criminal offenses committed by negligence for which is foreseen the sentence up to five years of imprisonment, except those cases that result in death. With the imposition of these measures is intended to prevent criminal proceedings against juveniles whenever is possible, rehabilitation and reintegration of juvenile in his/her community and the prevention of recidivist behaviour. Competent authority to impose them is the public prosecutor, the juvenile judge and juvenile court. And they are executed by the Kosovo Correctional Service.

  6. Lifetime measurements

    International Nuclear Information System (INIS)

    Fossan, D.B.; Warburton, E.K.

    1974-01-01

    Lifetime measurements are discussed, concentrating on the electronic technique, the recoil distance method (RDM), and the Doppler shift attenuation method (DSAM). A brief review of several indirect timing techniques is given, and their specific advantages and applicability are considered. The relationship between lifetimes of nuclear states and the nuclear structure information obtained from them is examined. A short discussion of channeling and microwave methods of lifetime measurement is presented. (23 figures, 171 references) (U.S.)

  7. Anthropomorphic measurements

    International Nuclear Information System (INIS)

    Wang, J.

    1998-01-01

    Based on decisions taken during the Research Coordination Meetings in Mito City 1988 and Bombay 1991, the participants were requested to provide data on physical measurement parameters of body height, body weight, sitting height, head circumference, neck circumference, chest circumference, chest width and chest depth which represented the age groups as newborn, 1 year, 5 years, 10 years, 15 years and adult 20-50 years. Accordingly, physical measurement data was obtained by participants from 9 countries

  8. Statistical process control: separating signal from noise in emergency department operations.

    Science.gov (United States)

    Pimentel, Laura; Barrueto, Fermin

    2015-05-01

    Statistical process control (SPC) is a visually appealing and statistically rigorous methodology very suitable to the analysis of emergency department (ED) operations. We demonstrate that the control chart is the primary tool of SPC; it is constructed by plotting data measuring the key quality indicators of operational processes in rationally ordered subgroups such as units of time. Control limits are calculated using formulas reflecting the variation in the data points from one another and from the mean. SPC allows managers to determine whether operational processes are controlled and predictable. We review why the moving range chart is most appropriate for use in the complex ED milieu, how to apply SPC to ED operations, and how to determine when performance improvement is needed. SPC is an excellent tool for operational analysis and quality improvement for these reasons: 1) control charts make large data sets intuitively coherent by integrating statistical and visual descriptions; 2) SPC provides analysis of process stability and capability rather than simple comparison with a benchmark; 3) SPC allows distinction between special cause variation (signal), indicating an unstable process requiring action, and common cause variation (noise), reflecting a stable process; and 4) SPC keeps the focus of quality improvement on process rather than individual performance. Because data have no meaning apart from their context, and every process generates information that can be used to improve it, we contend that SPC should be seriously considered for driving quality improvement in emergency medicine. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Against 'measurement'

    International Nuclear Information System (INIS)

    Bell, John

    1990-01-01

    This author of this article rails against the term ''measurement'' as it is commonly used in quantum mechanics. Many terms such as this are full of common place, everyday associations which are entirely inappropriate to the quantum world and lead to misunderstanding even amongst physicists. Measurement implies, at least for laboratory experiments, that the complexities of the real world have been simplified to the minimum number of variables. This can never be so for quantum mechanics where the act of measurement is intrinsic to the result, where even the mind of the observer plays a part. Three books on quantum mechanics are reviewed in an attempt to present a more precise comprehension of the meaning inside quantum mechanics. (UK)

  10. Measurements of

    CERN Document Server

    Angerami, Aaron; The ATLAS collaboration

    2018-01-01

    A measurement is presented of $\\gamma \\gamma \\rightarrow \\mu^{+} \\mu^{-}$ in Pb+Pb collisions recorded by the ATLAS detector at the LHC at $\\sqrt{s_{\\mathrm{NN}}}=5.02$ TeV with an integrated luminosity of 0.49 nb$^{-1}$. The angular and transverse momentum correlations between the muons are measured as a function of collision centrality. The lepton pairs are produced from $\\gamma \\gamma$ through the interaction of the large electromagnetic fields of the nuclei. The contribution from background sources of muon pairs is removed using a template fit method. In peripheral collisions, the muons exhibit a strong back-to-back correlation consistent with previous measurements of muon pair production in ultra-peripheral collisions. The angular correlations are observed to broaden significantly in central collisions. The modifications are qualitatively consistent with rescattering of the muons while passing through the hot matter produced in the collision.

  11. Microwave Measurements

    CERN Document Server

    Skinner, A D

    2007-01-01

    The IET has organised training courses on microwave measurements since 1983, at which experts have lectured on modern developments. Their lecture notes were first published in book form in 1985 and then again in 1989, and they have proved popular for many years with a readership beyond those who attended the courses. The purpose of this third edition of the lecture notes is to bring the latest techniques in microwave measurements to this wider audience. The book begins with a survey of the theory of current microwave circuits and continues with a description of the techniques for the measureme

  12. SAFETY MEASURES

    CERN Multimedia

    Relations with the Host States Service; Tel. 75152

    2001-01-01

    Following the recent terrorist attacks, the French authorities have introduced increased-vigilance measures («Vigipirate renforcé») as part of their prevention of terrorism campaign and have expressed the wish to extend these measures to the French part of the CERN site. The Organization has acceded to this request with the understanding that its international status will be respectd and has granted the French Gendarmerie right of access to the Prévessin site and to the LEP/LHC sites on French territory.

  13. Measuring anhedonia

    DEFF Research Database (Denmark)

    Rømer Thomsen, Kristine

    2015-01-01

    about pleasure, which is often, but not always accessible to conscious awareness." (Rømer Thomsen et al., 2015). This framework is in line with Treadway and Zald's (2011) proposal to differentiate between motivational and consummatory types of anhedonia, and stresses the need to combine traditional self......-report measures with behavioral measures or procedures. In time, this approach may lead to improved clinical assessment and treatment. In line with our reconceptualization, increasing evidence suggests that reward processing deficits are not restricted to impaired hedonic impact in major psychiatric disorders...

  14. Measuring Globalization

    OpenAIRE

    Andersen, Torben M.; Herbertsson, Tryggvi Thor

    2003-01-01

    The multivariate technique of factor analysis is used to combine several indicators of economic integration and international transactions into a single measure or index of globalization. The index is an alternative to the simple measure of openness based on trade, and it produces a ranking of countries over time for 23 OECD countries. Ireland is ranked as the most globalized country during the 1990?s, while the UK was at the top during the 1980?s. Some of the most notable changes in the rank...

  15. Radioactivity measurement

    International Nuclear Information System (INIS)

    Bohme, R.F.; Lazerson, M.M.

    1984-01-01

    A problem with ore sorting arrangements is that radiation is difficult to measure accurately while particles are moving at speed past the detector. This is particulary so when dealing with ores such as gold ores which have weak emissions. A method of measuring radioactive emissions from moving radioactive material includes the steps of shielding the radiation detector(s) so that the angle of acceptance of the receptor surface is restricted, and further shielding the shielded portion of the detector with a second material which is less radiation emissive than the material of the first shield. This second shield is between the first shield and the detector

  16. AMS measurements

    International Nuclear Information System (INIS)

    Lawson, E.M.

    1999-01-01

    Accelerator mass spectrometry (AMS) ia an ultrasensitive analysis technique using a system based on a nuclear particle accelerator and its beam transport system to detect and measure individual 14 C ions.. In AMS a 14 C abundance is obtained by comparing the measurement rates of 14 C and 13 C ions. This is not as simple as it sounds. The enormous difference in the numbers of the two isotopes makes it very hard to uniquely detect 14 C ions. For modern samples, those with the most 14 C, some 10 10 13 C ions leave the source for every 14 C ion. However, the use of an accelerator and various high energy techniques makes it possible to the detect the 14 C and to reject the 13 C. in order to achieve this high rejection efficiency the injection magnet is set to transmit only one isotope, namely 14 C. However, a subsequent measurement of 13 C must be made. The number and the rate of arrival of 13 C ions is such that individual ions cannot be measured, instead a 13 C current is measured in a Faraday cup. It is possible to alternate the injection magnet field between that to transmit 14 C and that to transmit 13 C. This method is known as slow cycling but suffers from significant dead (not useful) periods while the magnet field is changed and stabilises. Furthermore and more significantly, during this dead time changes in ion source output may occur distorting the 14 C/ 13 C ratio. We instead employ a method known as fast cycling which involves rapidly increasing the energy of the 13 C ions as they enter the injection magnet. This is achieved by the use of a high voltage (6.7 kV) pulser. We can also inject 12 C by this method although a 14.7 kV pulse is required. The switching time from one carbon isotope to another is only a fraction of a millisecond in this fast cycling method. Hence one has quasi-simultaneous measurement of 14 C and 13 C. Measurements of the 14 C/ 13 C ratio from a sample are always compared to the same ratio from an internationally accepted standard

  17. Measuring Trust

    OpenAIRE

    Glaeser, Edward Ludwig; Laibson, David I.; Scheinkman, Jose A.; Soutter, Christine L.

    2000-01-01

    We combine two experiments and a survey to measure trust and trustworthiness—two key components of social capital. Standard attitudinal survey questions about trust predict trustworthy behavior in our experiments much better than they predict trusting behavior. Trusting behavior in the experiments is predicted by past trusting behavior outside of the experiments. When individuals are closer socially, both trust and trustworthiness rise. Trustworthiness declines when partners are of differen...

  18. Radiation measurement

    International Nuclear Information System (INIS)

    Go, Sung Jin; Kim, Seung Guk; No, Gyeong Seok; Park, Myeong Hwan; Ann, Bong Seon

    1998-03-01

    This book explains technical terms about radiation measurement, which are radiation, radiation quantity and unit such as prefix of international unit, unit for defence purposes of radiation, coefficient of radiation and interaction, kinds and principles of radiation detector, ionization chamber, G-M counter, G-M tube, proportional counter, scintillation detector, semiconductor radiation detector, thermoluminescence dosimeter, PLD, others detector, radiation monitor, neutron detector, calibration of radiation detector, statistics of counting value, activation analysis and electronics circuit of radiation detector.

  19. Measuring phase with Stokes measurements

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2014-07-01

    Full Text Available Measurements Angela Dudley1, Giovanni Milione2, Robert Alfano2 and Andrew Forbes1. 1 CSIR National Laser Centre, Pretoria, South Africa. 2 Institute for Ultrafast Spectroscopy and Lasers, Physics Department, City College of New York,160 Convent Ave., New...

  20. Statistical process control for serially correlated data

    NARCIS (Netherlands)

    Wieringa, Jakob Edo

    1999-01-01

    Statistical Process Control (SPC) aims at quality improvement through reduction of variation. The best known tool of SPC is the control chart. Over the years, the control chart has proved to be a successful practical technique for monitoring process measurements. However, its usefulness in practice

  1. Detection and characterization of partially unfolded oligomers of the SH3 domain of α-Spectrin

    NARCIS (Netherlands)

    Casares, S.; Sadqi, M.; López-Mayorga, O.; Conejero-Lara, F.; van Nuland, N.A.J.

    2004-01-01

    For the purpose of equilibrium and kinetic folding-unfolding studies, the SH3 domain of α-spectrin (spc-SH3) has long been considered a classic two-state folding protein. In this work we have indeed observed that the thermal unfolding curves of spc-SH3 measured at pH 3.0 by differential scanning

  2. SU-G-TeP4-07: Automatic EPID-Based 2D Measurement of MLC Leaf Offset as a Quality Control Tool

    Energy Technology Data Exchange (ETDEWEB)

    Ritter, T; Moran, J [The University of Michigan, Ann Arbor, MI (United States); Schultz, B [University of Michigan, Ann Arbor, MI (United States); Kim, G [University of California, San Diego, La Jolla, CA (United States); Barnes, M [Calvary Mater Hospital Newcastle, Warratah, NSW (Australia); Perez, M [North Sydney Cancer Center, Sydney (Australia); Farrey, K [University of Chicago, Chicago, IL (United States); Popple, R [University Alabama Birmingham, Birmingham, AL (United States); Greer, P [Calvary Mater Newcastle, Newcastle (Australia)

    2016-06-15

    Purpose: The MLC dosimetric leaf gap (DLG) and transmission are measured parameters which impact the dosimetric accuracy of IMRT and VMAT plans. This investigation aims to develop an efficient and accurate routine constancy check of the physical DLG in two dimensions. Methods: The manufacturer’s recommended DLG measurement method was modified by using 5 fields instead of 11 and by utilizing the Electronic Portal Imaging Device (EPID). Validations were accomplished using an ion chamber (IC) in solid water and a 2D IC array. EPID data was collected for 6 months on multiple TrueBeam linacs using both Millennium and HD MLCs at 5 different clinics in an international consortium. Matlab code was written to automatically analyze the images and calculate the 2D results. Sensitivity was investigated by introducing deliberate leaf position errors. MLC calibration and initialization history was recorded to allow quantification of their impact. Results were analyzed using statistical process control (SPC). Results: The EPID method took approximately 5 minutes. Due to detector response, the EPID measured DLG and transmission differed from the IC values but were reproducible and consistent with changes measured using the ICs. For the Millennium MLC, the EPID measured DLG and transmission were both consistently lower than IC results. The EPID method was implemented as leaf offset and transmission constancy tests (LOC and TC). Based on 6 months of measurements, the initial leaf-specific action thresholds for changes from baseline were set to 0.1 mm. Upper and lower control limits for variation were developed for each machine. Conclusion: Leaf offset and transmission constancy tests were implemented on Varian HD and Millennium MLCs using an EPID and found to be efficient and accurate. The test is effective for monitoring MLC performance using dynamic delivery and performing process control on the DLG in 2D, thus enhancing dosimetric accuracy. This work was supported by a grant

  3. Measuring circuits

    CERN Document Server

    Graf, Rudolf F

    1996-01-01

    This series of circuits provides designers with a quick source for measuring circuits. Why waste time paging through huge encyclopedias when you can choose the topic you need and select any of the specialized circuits sorted by application?This book in the series has 250-300 practical, ready-to-use circuit designs, with schematics and brief explanations of circuit operation. The original source for each circuit is listed in an appendix, making it easy to obtain additional information.Ready-to-use circuits.Grouped by application for easy look-up.Circuit source listings

  4. Measuring progress

    DEFF Research Database (Denmark)

    Wahlberg, Ayo

    2007-01-01

    In recent years, sociological examinations of genetics, therapeutic cloning, neuroscience and tissue engineering have suggested that 'life itself' is currently being transformed through technique with profound implications for the ways in which we understand and govern ourselves and others...... in much the same way that mortality rates, life expectancy or morbidity rates can. By analysing the concrete ways in which human progress has been globally measured and taxonomised in the past two centuries or so, I will show how global stratifications of countries according to their states...

  5. Nuclear measurements

    International Nuclear Information System (INIS)

    Schenkel, R.

    2005-01-01

    Nuclear measurements play a fundamental role in the development of nuclear technology and the assurance of its peaceful use. They are also required in many non-power nuclear applications such as in nuclear medicine, agriculture, environmental protection, etc. This presentation will show examples of most recent advances in measurement methodology or technology in the areas described below. The Generation IV International Forum has selected six innovative reactor systems as candidates for a next generation of sustainable, economic and safe nuclear energy systems. The choice of the best options relies heavily on the availability of accurate nuclear data that can only be obtained, in an international effort, using highly specialised facilities. Significant efforts are being directed towards the partitioning and transmutation of highly active nuclear waste. Different concepts involving fast reactors or accelerator-driven systems are being studied in view of their transmutation capabilities. State of the art equipment has been developed to assess basic properties of nuclear fuel at very high burn-up; some fine examples of this work will be shown. Physical and chemical methods play a crucial role in the detection and identification of radioisotopes used in various stages of the nuclear fuel cycle. Radiation measurement techniques are used, for example, to monitor the quantities of uranium, plutonium and other actinide elements in fuel enrichment and reprocessing facilities. Another field of application of physical and chemical methods is the characterisation of nuclear material seized from illicit trafficking. Seized material has to be analysed in order to obtain clues on its origin and intended use and to prevent diversion of nuclear material from the same source in the future. A recent highlight in basic physics relates to nuclear fission and transmutation with high intensity lasers. Ultra-fast high intensity lasers can produce high energy (tens of MeV) photons through

  6. Measuring Quality

    DEFF Research Database (Denmark)

    Næsby, Torben

    local differences in the quality of day care facilities in Denmark (Nordahl et al, 2012; Hansen et al, 2016) and also that we in fact have little knowledge of whether the desired politically determined targets are being met or not and what the quality is really like. In order to measure the quality......The Danish Day Care Facilities Act (2015), which provides the curriculum on which day care education is based, does not stipulate very clearly what children should learn and therefore how educational processes in preschools should be organised. This means that we must accept that there are large...... of preschool in Denmark a new research project using the ECERS 3 instrument has been launched. This could capture quality from a global quality standard’s perspective, building the basis for a further investigation of practice in Danish early childhood provisions and centers in a more narrow approach...

  7. Spatial resolution measurements by Radia diagnostic software with SEDENTEXCT image quality phantom in cone beam CT for dental use.

    Science.gov (United States)

    Watanabe, Hiroshi; Nomura, Yoshikazu; Kuribayashi, Ami; Kurabayashi, Tohru

    2018-02-01

    We aimed to employ the Radia diagnostic software with the safety and efficacy of a new emerging dental X-ray modality (SEDENTEXCT) image quality (IQ) phantom in CT, and to evaluate its validity. The SEDENTEXCT IQ phantom and Radia diagnostic software were employed. The phantom was scanned using one medical full-body CT and two dentomaxillofacial cone beam CTs. The obtained images were imported to the Radia software, and the spatial resolution outputs were evaluated. The oversampling method was employed using our original wire phantom as a reference. The resultant modulation transfer function (MTF) curves were compared. The null hypothesis was that MTF curves generated using both methods would be in agreement. One-way analysis of variance tests were applied to the f50 and f10 values from the MTF curves. The f10 values were subjectively confirmed by observing the line pair modules. The Radia software reported the MTF curves on the xy-plane of the CT scans, but could not return f50 and f10 values on the z-axis. The null hypothesis concerning the reported MTF curves on the xy-plane was rejected. There were significant differences between the results of the Radia software and our reference method, except for f10 values in CS9300. These findings were consistent with our line pair observations. We evaluated the validity of the Radia software with the SEDENTEXCT IQ phantom. The data provided were semi-automatic, albeit with problems and statistically different from our reference. We hope the manufacturer will overcome these limitations.

  8. In Contact! Case Studies from the Long War. Volume I

    Science.gov (United States)

    2006-01-01

    lull, Bellavia called his platoon sergeant, Cantrell, on his radio. Cantrell, who was not with Meno, immediately responded yelling into the mike ...at <http://www.infoplease.com/ipa/A0107644.html>, accessed 12 June 2006. 3. Mike Tucker, Among Warriors in Iraq: True Grit, Special Ops, and...SGT Kennedy SPC Detman SPC Hubbard SPC Graff SPC Harris SPC Rullo SPC Kinzer SPC Sharples SPC Heesacker SPC Birkel SPC Schrad Regulator 3 SSG Castro SPC

  9. Measures and Trends U.S. and U.S.S.R. Strategic Force Effectiveness. (Sanitized)

    Science.gov (United States)

    1978-07-01

    the Anti-Submarine Warfare (AStiIW)rl,-, ip ± ,nse On thv avala4er if all sularines were on station, j each suhmarine would have over 150,000 squate ...V. Carter AIVA: fChIR of N!feft-tI:, .ta,6 uia KK ____~~~~~E~~~ SPC (con Ai*PW~ : ~ rfj tined) caal 40.teriai Ccrrdnd Oep.~ty ::.’ _~ Siff Departvtri

  10. Electricity electron measurement

    International Nuclear Information System (INIS)

    Kim, Sang Jin; Sung, Rak Jin

    1985-11-01

    This book deals with measurement of electricity and electron. It is divided into fourteen chapters, which depicts basic of electricity measurement, unit and standard, important electron circuit for measurement, instrument of electricity, impedance measurement, power and power amount measurement, frequency and time measurement, waveform measurement, record instrument and direct viewing instrument, super high frequency measurement, digital measurement on analog-digital convert, magnetic measurement on classification by principle of measurement, measurement of electricity application with principle sensors and systematization of measurement.

  11. The newest precision measurement

    International Nuclear Information System (INIS)

    Lee, Jing Gu; Lee, Jong Dae

    1974-05-01

    This book introduces basic of precision measurement, measurement of length, limit gauge, measurement of angles, measurement of surface roughness, measurement of shapes and locations, measurement of outline, measurement of external and internal thread, gear testing, accuracy inspection of machine tools, three dimension coordinate measuring machine, digitalisation of precision measurement, automation of precision measurement, measurement of cutting tools, measurement using laser, and point of choosing length measuring instrument.

  12. Propagation of Radiosonde Pressure Sensor Errors to Ozonesonde Measurements

    Science.gov (United States)

    Stauffer, R. M.; Morris, G.A.; Thompson, A. M.; Joseph, E.; Coetzee, G. J. R.; Nalli, N. R.

    2014-01-01

    Several previous studies highlight pressure (or equivalently, pressure altitude) discrepancies between the radiosonde pressure sensor and that derived from a GPS flown with the radiosonde. The offsets vary during the ascent both in absolute and percent pressure differences. To investigate this problem further, a total of 731 radiosonde-ozonesonde launches from the Southern Hemisphere subtropics to Northern mid-latitudes are considered, with launches between 2005 - 2013 from both longer-term and campaign-based intensive stations. Five series of radiosondes from two manufacturers (International Met Systems: iMet, iMet-P, iMet-S, and Vaisala: RS80-15N and RS92-SGP) are analyzed to determine the magnitude of the pressure offset. Additionally, electrochemical concentration cell (ECC) ozonesondes from three manufacturers (Science Pump Corporation; SPC and ENSCI-Droplet Measurement Technologies; DMT) are analyzed to quantify the effects these offsets have on the calculation of ECC ozone (O3) mixing ratio profiles (O3MR) from the ozonesonde-measured partial pressure. Approximately half of all offsets are 0.6 hPa in the free troposphere, with nearly a third 1.0 hPa at 26 km, where the 1.0 hPa error represents 5 persent of the total atmospheric pressure. Pressure offsets have negligible effects on O3MR below 20 km (96 percent of launches lie within 5 percent O3MR error at 20 km). Ozone mixing ratio errors above 10 hPa (30 km), can approach greater than 10 percent ( 25 percent of launches that reach 30 km exceed this threshold). These errors cause disagreement between the integrated ozonesonde-only column O3 from the GPS and radiosonde pressure profile by an average of +6.5 DU. Comparisons of total column O3 between the GPS and radiosonde pressure profiles yield average differences of +1.1 DU when the O3 is integrated to burst with addition of the McPeters and Labow (2012) above-burst O3 column climatology. Total column differences are reduced to an average of -0.5 DU when

  13. Practical precision measurement

    International Nuclear Information System (INIS)

    Kwak, Ho Chan; Lee, Hui Jun

    1999-01-01

    This book introduces basic knowledge of precision measurement, measurement of length, precision measurement of minor diameter, measurement of angles, measurement of surface roughness, three dimensional measurement, measurement of locations and shapes, measurement of screw, gear testing, cutting tools testing, rolling bearing testing, and measurement of digitalisation. It covers height gauge, how to test surface roughness, measurement of plan and straightness, external and internal thread testing, gear tooth measurement, milling cutter, tab, rotation precision measurement, and optical transducer.

  14. Measure and dimension functions: measurability and densities

    Science.gov (United States)

    Mattila, Pertti; Mauldin, R. Daniel

    1997-01-01

    During the past several years, new types of geometric measure and dimension have been introduced; the packing measure and dimension, see [Su], [Tr] and [TT1]. These notions are playing an increasingly prevalent role in various aspects of dynamics and measure theory. Packing measure is a sort of dual of Hausdorff measure in that it is defined in terms of packings rather than coverings. However, in contrast to Hausdorff measure, the usual definition of packing measure requires two limiting procedures, first the construction of a premeasure and then a second standard limiting process to obtain the measure. This makes packing measure somewhat delicate to deal with. The question arises as to whether there is some simpler method for defining packing measure and dimension. In this paper, we find a basic limitation on this possibility. We do this by determining the descriptive set-theoretic complexity of the packing functions. Whereas the Hausdorff dimension function on the space of compact sets is Borel measurable, the packing dimension function is not. On the other hand, we show that the packing dimension functions are measurable with respect to the [sigma]-algebra generated by the analytic sets. Thus, the usual sorts of measurability properties used in connection with Hausdorff measure, for example measures of sections and projections, remain true for packing measure.

  15. Origin and enhancement of spin polarized current in diluted magnetic oxides by oxygen vacancies

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Hsiung, E-mail: hchou@mail.nsysu.edu.tw; Yang, Kung-Shang; Tsao, Yao-Chung; Dwivedi, G. D.; Lin, Cheng-Pang [Department of Physics, National Sun Yat-Sen University, 70, Lienhai Road, Gushan District, Kaohsiung 804, Taiwan (China); Sun, Shih-Jye [Department of Applied Physics, National Kaohsiung University, 700, Gaoxiongdaxue Rd., Nanzi District, Kaohsiung 811, Taiwan (China); Lin, L. K.; Lee, S. F. [Institute of Physics, Academia Sinica, 128 Academia Road, Section 2, Nankang, Taipei 115, Taiwan (China)

    2016-04-04

    Spin polarized current (SPC) is a crucial characteristic of diluted magnetic oxides due to the potential application of oxides in spintronic devices. However, most research has been focused on ferromagnetic properties rather than polarization of electric current, because direct measurements are difficult and the origin of SPC has yet to be fully understood. The method to increase the SPC percentage is beyond practical consideration at present. To address this problem, we focus on the role of oxygen vacancies (V{sub O}) on SPC, which are controlled by growing the Co-doped ZnO thin-films at room temperature in a reducing atmosphere [Ar + (1%–30%)H{sub 2}]. We found that the conductivity increases with an increase of V{sub O} via two independent channels: the variable range hopping (VRH) within localized states and the itinerant transport in the conduction band. The point contact Andreev reflection measurements at 4.2 K, where the electric conduction is governed only by the VRH mechanism, prove that the current flowing in the VRH hopping channel is SPC. The percentage of SPC increases with the introduction of V{sub O} and increase in its concentration. The transport measurement shows that by manipulating V{sub O}, one can control the percentage of VRH hopping conduction such that it can even dominate room temperature conduction. The highest achieved SPC ratio at room temperature was 80%.

  16. Evaluation of efalizumab using safe psoriasis control

    Directory of Open Access Journals (Sweden)

    Henninger Eric

    2006-09-01

    Full Text Available Abstract Background Safe Psoriasis Control (SPC is an important comprehensive measure that is validated for the assessment of benefit:risk of psoriasis treatments, combining efficacy, quality of life, and safety measures. The objective of this analysis was to assess the benefit:risk of efalizumab, a novel biologic agent indicated for the treatment of moderate-to-severe plaque psoriasis, by applying the SPC to data from randomized, placebo-controlled clinical studies of efalizumab. Methods SPC was applied to week 12 data from four placebo-controlled, Phase III studies: three retrospective and one prospective, the latter including a cohort of "high-need" patients for whom existing therapies were inadequate or unsuitable. Results In the retrospective analysis, 39.4% of patients achieved SPC after 12 weeks of treatment with efalizumab, compared with 10.4% for placebo. In the prospective analysis, 34.3% of patients achieved SPC after 12 weeks of treatment with efalizumab, compared with 7.3% on placebo. Among high-need patients, 33.0% achieved SPC, compared with 3.4% on placebo. Conclusion Efalizumab has a favorable benefit:risk profile using the comprehensive outcome measure SPC.

  17. High drug payload curcumin nanosuspensions stabilized by mPEG-DSPE and SPC: in vitro and in vivo evaluation.

    Science.gov (United States)

    Hong, Jingyi; Liu, Yingying; Xiao, Yao; Yang, Xiaofeng; Su, Wenjing; Zhang, Mingzhu; Liao, Yonghong; Kuang, Haixue; Wang, Xiangtao

    2017-11-01

    Curcumin (CUR) is a promising drug candidate based on its broad bioactivities and good antitumor effect, but the application of CUR is potentially restricted because of its poor solubility and bioavailability. This study aims at developing a simple and effective drug delivery system for CUR to enhance its solubility and bioavailability thus to improve its antitumor efficacy. Curcumin nanosuspensions (CUR-NSps) were prepared by precipitation-ultrasonication method using mPEG2000-DSPE and soybean lecithin as a combined stabilizer. CUR-NSps with a high drug payload of 67.07% were successfully prepared. The resultant CUR-NSps had a mean particle size of 186.33 ± 2.73 nm with a zeta potential of -19.00 ± 1.31 mV. In vitro cytotoxicity assay showed that CUR-NSps exhibited enhanced cytotoxicity compared to CUR solution. The pharmacokinetics results demonstrated that CUR-NSps exhibited a significantly greater AUC 0-24 and prolonged MRT compared to CUR injections after intravenous administration. In the biodistribution study, CUR-NSps demonstrated enhanced biodistribution compared with CUR injections in liver, spleen, kidney, brain, and tumor. The CUR-NSps also showed improved antitumor therapeutic efficacy over the injections (70.34% versus 40.03%, p < 0.01). These results suggest that CUR-NSps might represent a promising drug formulation for intravenous administration of CUR for the treatment of cancer.

  18. Molecular Force Fields for Aqueous Electrolytes: SPC/E-Compatible Charged LJ Sphere Models and Their Limitations

    Czech Academy of Sciences Publication Activity Database

    Moučka, F.; Nezbeda, Ivo; Smith, W. R.

    2013-01-01

    Roč. 138, č. 15 (2013), s. 154102 ISSN 0021-9606 Grant - others:GA MŠMT(CZ) LH12019; GA ČR(CZ) GAP208/12/0105; NSERCC(CA) OGP1041 Institutional support: RVO:67985858 Keywords : free-energy * computer -simulation * water Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.122, year: 2013

  19. A Job-Linked Literacy Program for SPC: Are We Talking about Worker Training, Work Reorganization, or More Equitable Workplaces?

    Science.gov (United States)

    Sarmiento, Tony; Schurman, Susan

    Unions and employers currently operate in an environment that does not support investment in skill development. However, competitiveness demands that both work and the way workers are educated and trained be radically restructured. In high-performance workplaces, participatory labor-management approaches to job-linked basic skills development are…

  20. Fieldcrest Cannon, Inc. Advanced Technical Preparation. Statistical Process Control (SPC). Safety Section: Modules 1-3. Instructor Book.

    Science.gov (United States)

    Averitt, Sallie D.

    These three modules, which were developed for use by instructors in a manufacturing firm's advanced technical preparation program, contain the materials required to present the safety section of the plant's adult-oriented, job-specific competency-based training program. The 3 modules contain 12 lessons on the following topics: lockout/tagout…

  1. Performance of SEM scintillation detector evaluated by modulation transfer function and detective quantum efficiency function.

    Science.gov (United States)

    Bok, Jan; Schauer, Petr

    2014-01-01

    In the paper, the SEM detector is evaluated by the modulation transfer function (MTF) which expresses the detector's influence on the SEM image contrast. This is a novel approach, since the MTF was used previously to describe only the area imaging detectors, or whole imaging systems. The measurement technique and calculation of the MTF for the SEM detector are presented. In addition, the measurement and calculation of the detective quantum efficiency (DQE) as a function of the spatial frequency for the SEM detector are described. In this technique, the time modulated e-beam is used in order to create well-defined input signal for the detector. The MTF and DQE measurements are demonstrated on the Everhart-Thornley scintillation detector. This detector was alternated using the YAG:Ce, YAP:Ce, and CRY18 single-crystal scintillators. The presented MTF and DQE characteristics show good imaging properties of the detectors with the YAP:Ce or CRY18 scintillator, especially for a specific type of the e-beam scan. The results demonstrate the great benefit of the description of SEM detectors using the MTF and DQE. In addition, point-by-point and continual-sweep e-beam scans in SEM were discussed and their influence on the image quality was revealed using the MTF. © 2013 Wiley Periodicals, Inc.

  2. Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

    International Nuclear Information System (INIS)

    Wells, Jered R.; Dobbins, James T. III

    2012-01-01

    Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm −1 ) and approximate circular symmetry at frequencies below 4 mm −1 . While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm −1 . Slit measurement near 45° revealed radial asymmetry in the MTF resulting from the square

  3. Kathoey, un genre multiple Kathoey, Multiple Gender : Identity Adaptation and Negotiation Process among Thai MTF Transsexuals in Thailand

    Directory of Open Access Journals (Sweden)

    Cheera Thongkrajai

    2010-07-01

    Full Text Available Les kathoey, transgenres et transsexuels Male-to-Female thaïlandais s’adaptent pour trouver le rôle ou la présentation identitaire convenant aux contextes et aux interactions auxquels elles doivent faire face. Elles peuvent adopter une apparence ou un rôle plus masculin lorsque la situation dans laquelle elles se trouvent ne leur permet pas d’affirmer leur féminité ou que celle-ci pourrait leur nuire socialement. Elles peuvent également accentuer leur féminité pour exprimer leur sentiment identitaire. Les kathoey négocient leur place en faisant preuve de leurs qualités personnelles et de leurs compétences et en mettant également en évidence leurs autres privilèges : statut socio-économique, beauté, etc. pour gagner une reconnaissance sociale. Malgré leur marginalité due à leur différence de genre, elles tentent de s’intégrer dans leurs milieux sociaux en adaptant leur image identitaire, en assumant leurs responsabilités et en réussissant leur vie familiale et professionnelle.Thai male-to-female transsexuals, “kathoey” adapt themselves and adjust their roles and their physical identity i.e., their appearances to different interactional situations. They can adopt their appearance and play masculine roles in the situation in which revealing femininity would be inacceptable or would cause them problem socially. Occasionally, in some situations, they can do the opposite by showing off their femininity they confirm to others who they really are. Kathoey negotiate their identity and their social position by proving and emphasizing on their personal qualities, capacities and others privileges such as social and economical status, beauty, professional competency etc. to gain social acceptation and admiration. Even though they have been marginalized by the society, they tend to reintegrate themselves in their social environment by using different strategies of such as personal identities, showing of their professional success and achievement, outstanding family background, different social goals and expectation.

  4. Measuring Gender Dysphoria: A Multicenter Examination and Comparison of the Utrecht Gender Dysphoria Scale and the Gender Identity/Gender Dysphoria Questionnaire for Adolescents and Adults.

    Science.gov (United States)

    Schneider, Catharina; Cerwenka, Susanne; Nieder, Timo O; Briken, Peer; Cohen-Kettenis, Peggy T; De Cuypere, Griet; Haraldsen, Ira R; Kreukels, Baudewijntje P C; Richter-Appelt, Hertha

    2016-04-01

    This study examined two instruments measuring gender dysphoria within the multicenter study of the European Network for the Investigation of Gender Incongruence (ENIGI). The Utrecht Gender Dysphoria Scale (UGDS) and the Gender Identity/Gender Dysphoria Questionnaire for Adolescents and Adults (GIDYQ-AA) were examined for their definitions of gender dysphoria and their psychometric properties, and evaluated for their congruence in assessing the construct. The sample of 318 participants consisted of 178 male-to-females (MtF) and 140 female-to-males (FtM) who were recruited from the four ENIGI gender clinics. Both instruments were significantly correlated in the group of MtFs. For the FtM group, there was a trend in the same direction but smaller. Gender dysphoria was found to be defined differently in the two instruments, which led to slightly different findings regarding the subgroups. The UGDS detected a difference between the subgroups of early and late onset of gender identity disorder in the group of MtFs, whereas the GIDYQ-AA did not. For the FtM group, no significant effect of age of onset was found. Therefore, both instruments seem to capture not only similar but also different aspects of gender dysphoria. The UGDS focusses on bodily aspects, gender identity, and gender role, while the GIDYQ-AA addresses subjective, somatic, social, and sociolegal aspects. For future research, consistency in theory and definition of gender dysphoria is needed and should be in line with the DSM-5 diagnosis of gender dysphoria in adolescents and adults.

  5. Statistical process control for alpha spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, W; Majoras, R E [Oxford Instruments, Inc. P.O. Box 2560, Oak Ridge TN 37830 (United States); Joo, I O; Seymour, R S [Accu-Labs Research, Inc. 4663 Table Mountain Drive, Golden CO 80403 (United States)

    1995-10-01

    Statistical process control(SPC) allows for the identification of problems in alpha spectroscopy processes before they occur, unlike standard laboratory Q C which only identifies problems after a process fails. SPC tools that are directly applicable to alpha spectroscopy include individual X-charts and X-bar charts, process capability plots, and scatter plots. Most scientists are familiar with the concepts the and methods employed by SPC. These tools allow analysis of process bias, precision, accuracy and reproducibility as well as process capability. Parameters affecting instrument performance are monitored and analyzed using SPC methods. These instrument parameters can also be compared to sampling, preparation, measurement, and analysis Q C parameters permitting the evaluation of cause effect relationships. Three examples of SPC, as applied to alpha spectroscopy , are presented. The first example investigates background contamination using averaging to show trends quickly. A second example demonstrates how SPC can identify sample processing problems, analyzing both how and why this problem occurred. A third example illustrates how SPC can predict when an alpha spectroscopy process is going to fail. This allows for an orderly and timely shutdown of the process to perform preventative maintenance, avoiding the need to repeat costly sample analyses. 7 figs., 2 tabs.

  6. Statistical process control for alpha spectroscopy

    International Nuclear Information System (INIS)

    Richardson, W.; Majoras, R.E.; Joo, I.O.; Seymour, R.S.

    1995-01-01

    Statistical process control(SPC) allows for the identification of problems in alpha spectroscopy processes before they occur, unlike standard laboratory Q C which only identifies problems after a process fails. SPC tools that are directly applicable to alpha spectroscopy include individual X-charts and X-bar charts, process capability plots, and scatter plots. Most scientists are familiar with the concepts the and methods employed by SPC. These tools allow analysis of process bias, precision, accuracy and reproducibility as well as process capability. Parameters affecting instrument performance are monitored and analyzed using SPC methods. These instrument parameters can also be compared to sampling, preparation, measurement, and analysis Q C parameters permitting the evaluation of cause effect relationships. Three examples of SPC, as applied to alpha spectroscopy , are presented. The first example investigates background contamination using averaging to show trends quickly. A second example demonstrates how SPC can identify sample processing problems, analyzing both how and why this problem occurred. A third example illustrates how SPC can predict when an alpha spectroscopy process is going to fail. This allows for an orderly and timely shutdown of the process to perform preventative maintenance, avoiding the need to repeat costly sample analyses. 7 figs., 2 tabs

  7. Measuring probe for measurement of local velocities

    International Nuclear Information System (INIS)

    Casal, V.; Arnold, G.; Kirchner, R.; Kussmaul, H.; Miller, H.

    1988-03-01

    The report describes a method for measurement of local velocities. It bases on the detection of the propagation of a temperature pulse induced into the fluid. The method can also be applied in flowing liquid metals with superimposed magnetic field; in this case common measuring principles fail application. The measuring system discussed consists of, a measuring head, a heating system, amplifiers and a PC. The latter performs process operation, data sampling, and evaluation of velocity. The measuring head itself includes a miniaturized heater (as a pulse marker) heated by the heating system in a short pulse, and a number of thermocouples (sensors) for detection of signals. The design, construction, and examination of a developed measuring device is described. (orig.) [de

  8. MEASURE FOR MEASURE: A THRICE TOLD TALE

    Directory of Open Access Journals (Sweden)

    HALIMAH MOHAMED ALI

    2009-01-01

    Full Text Available This paper argues that Measure for Measure is a difficult play to perform because it has problematic themes, especially the theme of sexuality, that clash with the way of life and thinking of contemporary society. As such, any director who chooses to stage it must consider these difficulties and how to present them in a natural manner without making the audience feel that the whole production is contrived. The directors of the two major productions discussed in this paper tried their best to present a Measure for Measure that would be acceptable to the modern society. It is evident that there are many interpretations of the Duke and Isabella's characters and also of Isabella's reaction to the Duke's proposal at the end of the play. It can be concluded that no interpretation is wrong because each actor or director brings with him his own reading of the play, and every reading has been influenced by other performances and textual criticisms. Since Measure for Measure is a thematically rich play, it should not be confined to a single interpretation. The different performances of Measure for Measure have proven that theatre is experimental as well as ageless. Because it is a brilliant play with a myriad of interpretations, Measure for Measure will not cease to be a favourite for directors in times to come. It is not wrong to predict that fans of Shakespeare in general and of Measure for Measure in particular can look forward to many more productions.For experienced Shakespeare observers all performances are thrice-told tales. The perceiving eye absorbs the performance even as the mind's eye attends to the text. Both are augmented by the inner ear buzzing with those other voices, both critical and dramatic, carried by the observer into the theatre.(Crowl, Samuel 1992: 3

  9. Measuring transformers in energy measurement technology

    International Nuclear Information System (INIS)

    Vock, E.

    2009-01-01

    This article takes a look at the use of measurement transformers in energy measurement installations in the light of electricity market liberalisation. Such equipment is quoted as being long living and capital-intensive. Increasing requirements on the installation of measurement equipment between partners in a liberalised market are examined. The requirements placed by electricity market legislation on the systems for the various grid voltage levels are discussed. Both current and voltage measurement transformers are looked at and the requirements placed on their accuracy are discussed in detail.

  10. Monaural and binaural subjective modulation transfer functions in simple reverberation

    DEFF Research Database (Denmark)

    Thompson, Eric Robert; Dau, Torsten

    2008-01-01

    conditions, with single reflections at different arrival times in the two ears and with a simulated room impulse response. The monaural data describe a subjective MTF, which is similar to the physical MTF. An interaural modulation phase difference can create an interaural intensity fluctuation, which can......, M.R. (1981) Modulation transfer-functions: Definition and measurement, Acustica, 49, 179-182]. The envelope of a speech signal is critical for intelligibility, and the speech transmission index (STI) predicts the intelligibility of speech through a given transmission channel based on its MTF...

  11. Conversion Between Sine Wave and Square Wave Spatial Frequency Response of an Imaging System

    National Research Council Canada - National Science Library

    Nill, Norman B

    2001-01-01

    ...), is a primary image quality metric that is commonly measured with a sine wave target. The FBI certification program for commercial fingerprint capture devices, which MITRE actively supports, has an MTF requirement...

  12. The organizational measurement manual

    National Research Council Canada - National Science Library

    Wealleans, David

    2001-01-01

    ... Relationship of process to strategic measurements Summary 37 36Contents 19/10/2000 1:23 pm Page vi vi THE ORGANIZATIONAL MEASUREMENT MANUAL 4 PART 2 ESTABLISHING A PROCESS MEASUREMENT PROGRAMME...

  13. Measurements on Hearing

    DEFF Research Database (Denmark)

    Poulsen, Torben

    1996-01-01

    Background material for measurements of hearing for grammar school pupils. The note gives the necessary background for the exercise 'Measurement on Hearing'. The topics comprise sound and decibel, the ear, basic psychoacoustics, hearing threshold, audiometric measurement methods, speech and speech...

  14. Software product quality measurement

    OpenAIRE

    Godliauskas, Eimantas

    2016-01-01

    This paper analyses Ruby product quality measures, suggesting three new measures for Ruby product quality measurement tool Rubocop to measure Ruby product quality characteristics defined in ISO 2502n standard series. This paper consists of four main chapters. The first chapter gives a brief view of software product quality and software product quality measurement. The second chapter analyses object oriented quality measures. The third chapter gives a brief view of the most popular Ruby qualit...

  15. Semiconductor Electrical Measurements Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Semiconductor Electrical Measurements Laboratory is a research laboratory which complements the Optical Measurements Laboratory. The laboratory provides for Hall...

  16. Reconsidering formative measurement.

    Science.gov (United States)

    Howell, Roy D; Breivik, Einar; Wilcox, James B

    2007-06-01

    The relationship between observable responses and the latent constructs they are purported to measure has received considerable attention recently, with particular focus on what has become known as formative measurement. This alternative to reflective measurement in the area of theory-testing research is examined in the context of the potential for interpretational confounding and a construct's ability to function as a point variable within a larger model. Although these issues have been addressed in the traditional reflective measurement context, the authors suggest that they are particularly relevant in evaluating formative measurement models. On the basis of this analysis, the authors conclude that formative measurement is not an equally attractive alternative to reflective measurement and that whenever possible, in developing new measures or choosing among alternative existing measures, researchers should opt for reflective measurement. In addition, the authors provide guidelines for researchers dealing with existing formative measures. Copyright 2007 APA, all rights reserved.

  17. Industrial X-ray imaging based on scintillators and CMOS APS array: direct X-ray irradiation effects

    International Nuclear Information System (INIS)

    Kim, Kwang Hyun; Jeon, Sung Chae; Kim, Young Soo; Cho, Gyuseong

    2005-01-01

    To see the effects of the direct X-ray in a Lanex screen-coupled CMOS APS imager, we measured modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). These measurements were performed under the condition of non-destructive test (NDT). By increasing the cumulative exposure on the imager, the MTF was degraded, and also leading to the DQE degradation. Each parameter changed by the exposure is described in detail

  18. Perspectives on Measurement Instruction.

    Science.gov (United States)

    Airasian, Peter W.

    1991-01-01

    This paper seeks to identify ways of making measurement more relevant to classroom teachers, and making classroom realities more apparent to measurement specialists. Measurement elements of teacher education textbooks and courses, nontraditional assessment topics, informal classroom measurement techniques, terminological issues, and three types of…

  19. Can Virtue Be Measured?

    Science.gov (United States)

    Curren, Randall; Kotzee, Ben

    2014-01-01

    This article explores some general considerations bearing on the question of whether virtue can be measured. What is moral virtue? What are measurement and evaluation, and what do they presuppose about the nature of what is measured or evaluated? What are the prospective contexts of, and purposes for, measuring or evaluating virtue, and how would…

  20. Measuring Infant Memory.

    Science.gov (United States)

    Bogartz, Richard S.

    1996-01-01

    Reviews three response rate measures (in a baseline measurement, immediately after acquisition, and at a long-term retention test) of infant memory that are used in experiments involving infants' conditioned kicking. Compares these measures to a new measure, the fraction of kicking rate remaining after the retention interval. Explains the…

  1. Measuring thermal neutron characteristics

    International Nuclear Information System (INIS)

    Johnstone, C.W.; Jacobson, L.A.

    1983-01-01

    A method for providing a background-compensated measurement of the level of inducted radiation within an earth formation is claimed. The formation is irradiated with a discrete burst of neutrons and the level of radiation in the formation measured. The level of background radiation is then measured. An average level of both measurements is obtained

  2. Radon flux measurement methodologies

    International Nuclear Information System (INIS)

    Nielson, K.K.; Rogers, V.C.

    1984-01-01

    Five methods for measuring radon fluxes are evaluated: the accumulator can, a small charcoal sampler, a large-area charcoal sampler, the ''Big Louie'' charcoal sampler, and the charcoal tent sampler. An experimental comparison of the five flux measurement techniques was also conducted. Excellent agreement was obtained between the measured radon fluxes and fluxes predicted from radium and emanation measurements

  3. Measurement of communication

    International Nuclear Information System (INIS)

    1998-08-01

    This book is one of series of information communication, which deals with measurement of communication. It is divided into six chapters. The contents are foundation of measurement with classification and principle, Basic measurement on current, voltage, electric resistance, power and impedance, measurement of communication line with way by L3 tester, BW tester and pulse tester, measurement of optical fiber cable of equipment and method, Test and measurement of information communication equipment about test of modulator and use, measurement of cable broadcasting equipment on transmission level and main transmission equipment.

  4. Inspector measurement verification activities

    International Nuclear Information System (INIS)

    George, R.S.; Crouch, R.

    e most difficult and complex activity facing a safeguards inspector involves the verification of measurements and the performance of the measurement system. Remeasurement is the key to measurement verification activities. Remeasurerements using the facility's measurement system provide the bulk of the data needed for determining the performance of the measurement system. Remeasurements by reference laboratories are also important for evaluation of the measurement system and determination of systematic errors. The use of these measurement verification activities in conjunction with accepted inventory verification practices provides a better basis for accepting or rejecting an inventory. (U.S.)

  5. Broadband Radiometric LED Measurements

    OpenAIRE

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-01-01

    At present, broadband radiometric measurements of LEDs with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(��) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irr...

  6. Temperature Measurements in the Magnetic Measurement Facility

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Zachary

    2010-12-13

    Several key LCLS undulator parameter values depend strongly on temperature primarily because of the permanent magnet material the undulators are constructed with. The undulators will be tuned to have specific parameter values in the Magnetic Measurement Facility (MMF). Consequently, it is necessary for the temperature of the MMF to remain fairly constant. Requirements on undulator temperature have been established. When in use, the undulator temperature will be in the range 20.0 {+-} 0.2 C. In the MMF, the undulator tuning will be done at 20.0 {+-} 0.1 C. For special studies, the MMF temperature set point can be changed to a value between 18 C and 23 C with stability of {+-}0.1 C. In order to ensure that the MMF temperature requirements are met, the MMF must have a system to measure temperatures. The accuracy of the MMF temperature measurement system must be better than the {+-}0.1 C undulator tuning temperature tolerance, and is taken to be {+-}0.01 C. The temperature measurement system for the MMF is under construction. It is similar to a prototype system we built two years ago in the Sector 10 alignment lab at SLAC. At that time, our goal was to measure the lab temperature to {+-}0.1 C. The system has worked well for two years and has maintained its accuracy. For the MMF system, we propose better sensors and a more extensive calibration program to achieve the factor of 10 increase in accuracy. In this note we describe the measurement system under construction. We motivate our choice of system components and give an overview of the system. Most of the software for the system has been written and will be discussed. We discuss error sources in temperature measurements and show how these errors have been dealt with. The calibration system is described in detail. All the LCLS undulators must be tuned in the Magnetic Measurement Facility at the same temperature to within {+-}0.1 C. In order to ensure this, we are building a system to measure the temperature of the

  7. Power Curve Measurements REWS

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Vesth, Allan

    This report describes the power curve measurements carried out on a given wind turbine in a chosen period. The measurements were carried out following the measurement procedure in the draft of IEC 61400-12-1 Ed.2 [1], with some deviations mostly regarding uncertainty calculation. Here, the refere......This report describes the power curve measurements carried out on a given wind turbine in a chosen period. The measurements were carried out following the measurement procedure in the draft of IEC 61400-12-1 Ed.2 [1], with some deviations mostly regarding uncertainty calculation. Here......, the reference wind speed used in the power curve is the equivalent wind speed obtained from lidar measurements at several heights between lower and upper blade tip, in combination with a hub height meteorological mast. The measurements have been performed using DTU’s measurement equipment, the analysis...

  8. Vessel size measurements in angiograms: Manual measurements

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Dmochowski, Jacek; Nazareth, Daryl P.; Miskolczi, Laszlo; Nemes, Balazs; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2003-01-01

    Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical practice, choosing to indicate the edges of vessels and catheters to determine sizes and calibrate magnifications, i.e., manual measurements. Thus, we undertook an investigation of the accuracy and precision of vessel sizes calculated from manually indicated edges of vessels. Manual measurements were performed by three neuroradiologists and three physicists. Vessel sizes ranged from 0.1-3.0 mm in simulation studies and 0.3-6.4 mm in phantom studies. Simulation resolution functions had full-widths-at-half-maximum (FWHM) ranging from 0.0 to 0.5 mm. Phantom studies were performed with 4.5 in., 6 in., 9 in., and 12 in. image intensifier modes, magnification factor = 1, with and without zooming. The accuracy and reproducibility of the measurements ranged from 0.1 to 0.2 mm, depending on vessel size, resolution, and pixel size, and zoom. These results indicate that manual measurements may have accuracies comparable to automated techniques for vessels with sizes greater than 1 mm, but that automated techniques which take into account the resolution function should be used for vessels with sizes smaller than 1 mm

  9. Performance evaluation of real time radiographic systems

    International Nuclear Information System (INIS)

    Venkatraman, B.; Saravanan, S.; Jayakumar, T.; Kalyanasundaram, P.; Baldev Raj

    1996-01-01

    The Real Time Radiography (RTR) system can be studied completely by knowing the modulation transfer function (MTF) of the whole system. The MTF curve is a special form of contrast/detail-size diagram in which the image contrast is plotted against the spatial frequency of a test object measured in line-pairs per millimetre (lp/mm). MTF curves are widely used to measure the characteristics of optical equipment, particularly for assessing the contribution of individual items in a complex imaging transfer system. Codes of practice indicate that the image intensifier systems should be checked periodically to assess its performance through the use of MTF curves and step wedges for contrast ratio. Authors, instead, suggest the use of performance curves which are simple to obtain and can be easily interpreted by radiographers. (author)

  10. Medipix3 Demonstration and understanding of near ideal detector performance for 60 & 80 keV electrons

    CERN Document Server

    Mir, J.A.; MacInnes, R.; Gough, C.; Plackett, R.; Shipsey, I.; Sawada, H.; MacLaren, I.; Ballabriga, R.; Maneuski, D.; O'Shea, V.; McGrouther, D.; Kirkland, A.I.

    2016-01-01

    In our article we report first quantitative measurements of imaging performance for the current generation of hybrid pixel detector, Medipix3, as direct electron detector. Utilising beam energies of 60 & 80 keV, measurements of modulation transfer function (MTF) and detective quantum efficiency (DQE) have revealed that, in single pixel mode (SPM), energy threshold values can be chosen to maximize either the MTF or DQE, obtaining values near to, or even exceeding, those for an ideal detector. We have demonstrated that the Medipix3 charge summing mode (CSM) can deliver simultaneous, near ideal values of both MTF and DQE. To understand direct detection performance further we have characterized the detector response to single electron events, building an empirical model which can predict detector MTF and DQE performance based on energy threshold. Exemplifying our findings we demonstrate the Medipix3 imaging performance, recording a fully exposed electron diffraction pattern at 24-bit depth and images in SPM a...

  11. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    OpenAIRE

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC ...

  12. Measurement of effective detective quantum efficiency for a photon counting scanning mammography system and comparison with two flat panel full-field digital mammography systems

    Science.gov (United States)

    Wood, Tim J.; Moore, Craig S.; Saunderson, John R.; Beavis, Andrew W.

    2018-01-01

    Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a useful metric for the optimisation of clinical imaging systems. The aim of this study was to develop a methodology for measuring eDQE and eDE on a Philips microdose mammography (MDM) L30 photon counting scanning system, and to compare performance with two conventional flat panel systems. A custom made lead-blocker was manufactured to enable the accurate determination of dose measurements, and modulation transfer functions were determined free-in-air at heights of 2, 4 and 6 cm above the breast support platform. eDQE were calculated for a Philips MDM L30, Hologic Dimensions and Siemens Inspiration digital mammography system for 2, 4 and 6 cm thick poly(methyl methacrylate) (PMMA). The beam qualities (target/filter and kilovoltage) assessed were those selected by the automatic exposure control, and anti-scatter grids were used where available. Measurements of eDQE demonstrate significant differences in performance between the slit- and scan-directions for the photon counting imaging system. MTF has been shown to be the limiting factor in the scan-direction, which results in a rapid fall in eDQE at mid-to-high spatial frequencies. A comparison with two flat panel mammography systems demonstrates that this may limit image quality for small details, such as micro-calcifications, which correlates with a more conventional image quality assessment with the CDMAM phantom. eDE has shown the scanning photon counting system offers superior performance for low spatial frequencies, which will be important for the detection of large low contrast masses. Both eDQE and eDE are proposed as useful metrics that should enable optimisation of the Philips MDM L30.

  13. Some mass measurement problems

    International Nuclear Information System (INIS)

    Merritt, J.S.

    1976-01-01

    Concerning the problem of determining the thickness of a target, an uncomplicated approach is to measure its mass and area and take the quotient. This paper examines the mass measurement aspect of such an approach. (author)

  14. Developing Effective Performance Measures

    Science.gov (United States)

    2014-10-14

    University When Performance Measurement Goes Bad Laziness Vanity Narcissism Too Many Pettiness Inanity 52 Developing Effective...Kasunic, October 14, 2014 © 2014 Carnegie Mellon University Narcissism Measuring performance from the organization’s point of view, rather than from

  15. AEROSOL AND GAS MEASUREMENT

    Science.gov (United States)

    Measurements provide fundamental information for evaluating and managing the impact of aerosols on air quality. Specific measurements of aerosol concentration and their physical and chemical properties are required by different users to meet different user-community needs. Befo...

  16. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Older Adults Overcoming Barriers Measuring Physical Activity Intensity Target Heart Rate & Estimated Maximum Heart Rate Perceived Exertion ( ... a heavy backpack Other Methods of Measuring Intensity Target Heart Rate and Estimated Maximum Heart Rate Perceived ...

  17. Estimation of measurement variances

    International Nuclear Information System (INIS)

    Jaech, J.L.

    1984-01-01

    The estimation of measurement error parameters in safeguards systems is discussed. Both systematic and random errors are considered. A simple analysis of variances to characterize the measurement error structure with biases varying over time is presented

  18. Emissions & Measurements - Black Carbon

    Science.gov (United States)

    Emissions and Measurement (EM) research activities performed within the National Risk Management Research Lab NRMRL) of EPA's Office of Research and Development (ORD) support measurement and laboratory analysis approaches to accurately characterize source emissions, and near sour...

  19. How Is PTSD Measured?

    Science.gov (United States)

    ... Public » Is it PTSD? » How is PTSD Measured? PTSD: National Center for PTSD Menu Menu PTSD PTSD Home For the Public ... code here Enter ZIP code here How is PTSD Measured? Public This section is for Veterans, General ...

  20. In praise of measurement

    International Nuclear Information System (INIS)

    Mermin, D.N.

    2005-01-01

    Full text: A quantum computer provides a toy universe in which to reexamine many aspects of quantum mechanics and quantum metaphysics. In particular measurement, against which John Bell unleashed one of his most elegant polemics, plays a transparent role. Since all measurements can be constructed out of identical 1-Qbit measurement gates, such obscurity as there is in the notion of measurement reduces to the obscurity, if any, of the elementary 1-Qbit gate. The 1-Qbit measurement gate is insufficiently celebrated. Without it the quantum computer has, in Abner Shimony's admirable words, 'no foreign policy'. Without it no computation has been done. without it no computation can begin. Without it there can be no error correction. Measurement takes coherence away but measurement also gives coherence. Praised be measurement. (author)

  1. Structural Measures - Hospital

    Data.gov (United States)

    U.S. Department of Health & Human Services — A list of hospitals and the structural measures they report. A structural measure reflects the environment in which hospitals care for patients, for example, whether...

  2. MDS Quality Measures

    Data.gov (United States)

    U.S. Department of Health & Human Services — A list of the quality measures displayed on Nursing Home Compare, excluding Measures of Rehospitalization, Emergency Room Visit, and Community Discharge. Each row...

  3. Measuring Pollution Prevention

    Science.gov (United States)

    Measuring results is an essential component of any successful P2 program and is one way to determine the success of a technical assistance or training effort. This page introduces the concept of P2 measurement.

  4. Spectrum and network measurements

    CERN Document Server

    Witte, Robert A

    2014-01-01

    This new edition of Spectrum and Network Measurements enables readers to understand the basic theory, relate it to measured results, and apply it when creating new designs. This comprehensive treatment of frequency domain measurements successfully consolidates all the pertinent theory into one text. It covers the theory and practice of spectrum and network measurements in electronic systems. It also provides thorough coverage of Fourier analysis, transmission lines, intermodulation distortion, signal-to-noise ratio and S-parameters.

  5. Temperature measuring device

    International Nuclear Information System (INIS)

    Brixy, H.

    1977-01-01

    The temperature measuring device is equipped with an electric resistor installed within a metal shroud tube so as to be insulated from it, the noise voltage of which resistor is fed to a measuring unit. The measuring junctions of one or two thermocouples are connected with the electric resistor and the legs of one or both thermocouples can be connected to the measuring unit by means of a switch. (orig.) [de

  6. Power Curve Measurements FGW

    DEFF Research Database (Denmark)

    Georgieva Yankova, Ginka; Federici, Paolo

    This report describes power curve measurements carried out on a given turbine in a chosen period. The measurements are carried out in accordance to IEC 61400-12-1 Ed. 1 and FGW Teil 2.......This report describes power curve measurements carried out on a given turbine in a chosen period. The measurements are carried out in accordance to IEC 61400-12-1 Ed. 1 and FGW Teil 2....

  7. Strain measurement technique

    International Nuclear Information System (INIS)

    1987-01-01

    The 10 contributions are concerned with selected areas of application, such as strain measurements in wood, rubber/metal compounds, sets of strain measurements on buildings, reinforced concrete structures without gaps, pipes buried in the ground and measurements of pressure fluctuations. To increase the availability and safety of plant, stress analyses were made on gas turbine rotors with HT-DMS or capacitive HT-DMS (high temperature strain measurements). (DG) [de

  8. Foundations of measurement

    CERN Document Server

    Suppes, Patrick

    1989-01-01

    Foundations of Measurement offers the most coherently organized treatment of the topics and issues central to measurement. Much of the research involved has been scattered over several decades and a multitude of journals--available in many instances only to specialties. With the publication of Volumes two and three of this important work, Foundations of Measurement is the most comprehensive presentation in the area of measurement.

  9. Reconsidering Formative Measurement

    Science.gov (United States)

    Howell, Roy D.; Breivik, Einar; Wilcox, James B.

    2007-01-01

    The relationship between observable responses and the latent constructs they are purported to measure has received considerable attention recently, with particular focus on what has become known as formative measurement. This alternative to reflective measurement in the area of theory-testing research is examined in the context of the potential…

  10. Power Curve Measurements

    DEFF Research Database (Denmark)

    Federici, Paolo; Kock, Carsten Weber

    This report describes the power curve measurements performed with a nacelle LIDAR on a given wind turbine in a wind farm and during a chosen measurement period. The measurements and analysis are carried out in accordance to the guidelines in the procedure “DTU Wind Energy-E-0019” [1]. The reporting...

  11. Power Curve Measurements, FGW

    DEFF Research Database (Denmark)

    Vesth, Allan; Kock, Carsten Weber

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...... analyze of power performance of the turbine....

  12. Power Curve Measurements

    DEFF Research Database (Denmark)

    Federici, Paolo; Vesth, Allan

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...... analyze of power performance of the turbine....

  13. Power Curve Measurements

    DEFF Research Database (Denmark)

    Villanueva, Héctor; Gómez Arranz, Paula

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...... analyze of power performance of the turbine...

  14. Standards for holdup measurement

    International Nuclear Information System (INIS)

    Zucker, M.S.

    1982-01-01

    Holdup measurement, needed for material balance, depend intensively on standards and on interpretation of the calibration procedure. More than other measurements, the calibration procedure using the standard becomes part of the standard. Standards practical for field use and calibration techniques have been developed. While accuracy in holdup measurements is comparatively poor, avoidance of bias is a necessary goal

  15. Coating thickness measurement

    International Nuclear Information System (INIS)

    1976-12-01

    The standard specifies measurements of the coating thickness, which make use of beta backscattering and/or x-ray fluorescence. For commonly used combinations of coating material and base material the appropriate measuring ranges and radionuclides to be used are given for continuous as well as for discontinuous measurements

  16. Measuring agricultural policy bias

    DEFF Research Database (Denmark)

    Jensen, Henning Tarp; Robinson, Sherman; Tarp, Finn

    2010-01-01

    Measurement is a key issue in the literature on price incentive bias induced by trade policy. We introduce a general equilibrium measure of the relative effective rate of protection, which generalizes earlier protection measures. For our fifteen sample countries, results indicate that the agricul...

  17. Power Curve Measurements FGW

    DEFF Research Database (Denmark)

    Federici, Paolo; Kock, Carsten Weber

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...... analyze of power performance of the turbine...

  18. Evaluation of the modulation transfer function of megavoltage X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung-Whan [The Catholic University of Korea, Seoul (Korea, Republic of); The Shingu University College of Korea, Seongnam (Korea, Republic of); Kim, Ki-Won [Samsung Medical Center, Seoul (Korea, Republic of); Kim, Jung-Min; Choi, In-Seok [Korea University, Seoul (Korea, Republic of); Jeong, Hoi-Woun [The Baekseok Culture University College of Korea, Cheon-an (Korea, Republic of); Son, Soon-Yong; Back, Geum-Mun [Asan Medical Center, Seoul (Korea, Republic of); Jung, Jae-Hong [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Jung, Jae-Yong; Choe, Bo-Young [The Catholic University of Korea, Seoul (Korea, Republic of)

    2014-12-15

    The modulation transfer function (MTF) must be measured against the requirements of the specific digital imaging application under consideration in order to evaluate the performance of detector equipment and to further develop the detector by performing quality-assurance (QA) procedures. The purpose of this study was to measure the MTF in digital megavoltage images (DMVs) for radiation therapy (RT) by using an edge block. We used 6 megavolts (MVs) of energy for the pre-sampling MTF, along with a photo-stimulating phosphor-based computed radiography (CR) system and a hexalon lead screen that contained a terbium-doped gadolinium oxysulfide granular phosphor (Gd{sub 2}O{sub 2}S:Tb). The DMV MTF was measured at both low and high resolutions according to changes in the dose in monitor units (MUs) by using four different detector combinations: CR-IP (image plate: photo-stimulable phosphor screen), CR-IP-Lead (image plate + lead screen), CR-IPRegular (fast front screen + image plate + fast front screen) and CR-IP-Fast (fast back screen + image plate + fast front screen). At a low resolution, the MTF 50% and the MTF 10% when using the CR-IP detector increased by about 30% and 46%, in proportion to the increase in the dose from 1 to 20 MU, respectively. At a high resolution, the CR-IP and the CR-IP-Lead detectors showed increases in the MTF of about 8% or 10% when the dose increased from 1 to 20 MU. The present study, therefore, evaluates how edge methods can be helpful in taking MTF measurements during QA tests of a megavoltage imaging (MVI) system.

  19. Evaluation of the modulation transfer function of megavoltage X-rays

    International Nuclear Information System (INIS)

    Min, Jung-Whan; Kim, Ki-Won; Kim, Jung-Min; Choi, In-Seok; Jeong, Hoi-Woun; Son, Soon-Yong; Back, Geum-Mun; Jung, Jae-Hong; Jung, Jae-Yong; Choe, Bo-Young

    2014-01-01

    The modulation transfer function (MTF) must be measured against the requirements of the specific digital imaging application under consideration in order to evaluate the performance of detector equipment and to further develop the detector by performing quality-assurance (QA) procedures. The purpose of this study was to measure the MTF in digital megavoltage images (DMVs) for radiation therapy (RT) by using an edge block. We used 6 megavolts (MVs) of energy for the pre-sampling MTF, along with a photo-stimulating phosphor-based computed radiography (CR) system and a hexalon lead screen that contained a terbium-doped gadolinium oxysulfide granular phosphor (Gd 2 O 2 S:Tb). The DMV MTF was measured at both low and high resolutions according to changes in the dose in monitor units (MUs) by using four different detector combinations: CR-IP (image plate: photo-stimulable phosphor screen), CR-IP-Lead (image plate + lead screen), CR-IPRegular (fast front screen + image plate + fast front screen) and CR-IP-Fast (fast back screen + image plate + fast front screen). At a low resolution, the MTF 50% and the MTF 10% when using the CR-IP detector increased by about 30% and 46%, in proportion to the increase in the dose from 1 to 20 MU, respectively. At a high resolution, the CR-IP and the CR-IP-Lead detectors showed increases in the MTF of about 8% or 10% when the dose increased from 1 to 20 MU. The present study, therefore, evaluates how edge methods can be helpful in taking MTF measurements during QA tests of a megavoltage imaging (MVI) system.

  20. Determination of the Modulation Transfer Function of Screen-Film Combinations in X-ray photography by the grating method

    International Nuclear Information System (INIS)

    Hoeschen, D.

    1987-01-01

    An intercomparison experiment concerning the determination of the Modulation Transfer Function (MTF) of Screen-Film Combinations in x-ray photography by the grating method was made. Six laboratories located in four countries participated. Each laboratory has used its own, individually developed measurement procedure. The results have shown a surprisingly good agreement, the standard deviation (1 σ value) of MTF values reported by the different laboratories was about ± 0.02

  1. Short communication: Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count.

    Science.gov (United States)

    Koop, G; Dik, N; Nielen, M; Lipman, L J A

    2010-06-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC (Fossomatic 5000, Foss, Hillerød, Denmark) and TBC (BactoScan FC 150, Foss) were measured. Staphylococcal count was correlated to SCC (r=0.40), TBC (r=0.51), and SPC (r=0.53). Coliform count was correlated to TBC (r=0.33), but not to any of the other variables. Staphylococcus aureus did not correlate to SCC. The contribution of the staphylococcal count to the SPC was 31%, whereas the coliform count comprised only 1% of the SPC. The agreement of the repeated measurements was low. This study indicates that staphylococci in goat bulk milk are related to SCC and make a significant contribution to SPC. Because of the high variation in bacterial counts, repeated sampling is necessary to draw valid conclusions from bulk milk culturing. 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  2. Estimation of measurement variances

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    In the previous two sessions, it was assumed that the measurement error variances were known quantities when the variances of the safeguards indices were calculated. These known quantities are actually estimates based on historical data and on data generated by the measurement program. Session 34 discusses how measurement error parameters are estimated for different situations. The various error types are considered. The purpose of the session is to enable participants to: (1) estimate systematic error variances from standard data; (2) estimate random error variances from data as replicate measurement data; (3) perform a simple analysis of variances to characterize the measurement error structure when biases vary over time

  3. Measure and integration theory

    CERN Document Server

    Burckel, Robert B

    2001-01-01

    This book gives a straightforward introduction to the field as it is nowadays required in many branches of analysis and especially in probability theory. The first three chapters (Measure Theory, Integration Theory, Product Measures) basically follow the clear and approved exposition given in the author's earlier book on ""Probability Theory and Measure Theory"". Special emphasis is laid on a complete discussion of the transformation of measures and integration with respect to the product measure, convergence theorems, parameter depending integrals, as well as the Radon-Nikodym theorem. The fi

  4. Precision electroweak measurements

    International Nuclear Information System (INIS)

    Demarteau, M.

    1996-11-01

    Recent electroweak precision measurements fro e + e - and p anti p colliders are presented. Some emphasis is placed on the recent developments in the heavy flavor sector. The measurements are compared to predictions from the Standard Model of electroweak interactions. All results are found to be consistent with the Standard Model. The indirect constraint on the top quark mass from all measurements is in excellent agreement with the direct m t measurements. Using the world's electroweak data in conjunction with the current measurement of the top quark mass, the constraints on the Higgs' mass are discussed

  5. Measurement of true density

    International Nuclear Information System (INIS)

    Carr-Brion, K.G.; Keen, E.F.

    1982-01-01

    System for determining the true density of a fluent mixture such as a liquid slurry, containing entrained gas, such as air comprises a restriction in pipe through which at least a part of the mixture is passed. Density measuring means such as gamma-ray detectors and source measure the apparent density of the mixture before and after its passage through the restriction. Solid-state pressure measuring devices are arranged to measure the pressure in the mixture before and after its passage through the restriction. Calculating means, such as a programmed microprocessor, determine the true density from these measurements using relationships given in the description. (author)

  6. Coordinate measuring machines

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo

    This document is used in connection with three exercises of 2 hours duration as a part of the course GEOMETRICAL METROLOGY AND MACHINE TESTING. The exercises concern three aspects of coordinate measuring: 1) Measuring and verification of tolerances on coordinate measuring machines, 2) Traceabilit...... and uncertainty during coordinate measurements, 3) Digitalisation and Reverse Engineering. This document contains a short description of each step in the exercise and schemes with room for taking notes of the results.......This document is used in connection with three exercises of 2 hours duration as a part of the course GEOMETRICAL METROLOGY AND MACHINE TESTING. The exercises concern three aspects of coordinate measuring: 1) Measuring and verification of tolerances on coordinate measuring machines, 2) Traceability...

  7. Performance Measurement und Environmental Performance Measurement

    OpenAIRE

    Sturm, Anke

    2000-01-01

    Die Zielsetzung der vorliegenden Dissertationsschrift besteht in der Entwicklung einer systematisierten Vorgehensweise, eines Controllingmodells, zur unternehmensinternen Umweltleistungsmessung. Das entwickelte Environmental Performance Measurement (EPM)-Modell umfaßt die fünf Stufen Festlegung der Ziele der Umweltleistungsmessung (1. Stufe), Erfassung der Umwelteinflüsse nach der ökologischen Erfolgsspaltung (2. Stufe), Bewertung der Umwelteinflüsse auf der Grundlage des qualitätszielbezogen...

  8. Measurement control program

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    A measurement control program for the model plant is described. The discussion includes the technical basis for such a program, the application of measurement control principles to each measurement, and the use of special experiments to estimate measurement error parameters for difficult-to-measure materials. The discussion also describes the statistical aspects of the program, and the documentation procedures used to record, maintain, and process the basic data. The purpose of the session is to enable participants to: (1) understand the criteria for this type of a measurement control program; (2) understand the kinds of physical standards required for the various measurement processes, e.g., weighing, analytical, NDA; (3) understand the need for and importance of a measurement control program; (4) understand the need for special experiments to provide an improved basis for the measurement of difficult-to-measure materials; (5) understand the general scope of the program's statistical aspects; and (6) understand the basis and scope of the documentation procedures

  9. Evaluation of the resolving power of different angles in MPR images of 16DAS-MDCT

    International Nuclear Information System (INIS)

    Kimura, Mikio; Usui, Junshi; Nozawa, Takeo

    2007-01-01

    In this study, we evaluated the resolving power of three-dimensional (3D) multiplanar reformation (MPR) images with various angles by using 16 data acquisition system multi detector row computed tomography (16DAS-MDCT). We reconstructed the MPR images using data with a 0.75 mm slice thickness of the axial image in this examination. To evaluate resolving power, we used an original new phantom (RC phantom) that can be positioned at any slice angle in MPR images. We measured the modulation transfer function (MTF) by using the methods of measuring pre-sampling MTF, and used Fourier transform of image data of the square wave chart. The scan condition and image reconstruction condition that were adopted in this study correspond to the condition that we use for three-dimensional computed tomographic angiography(3D-CTA) examination of the head in our hospital. The MTF of MPR images showed minimum values at slice angles in parallel with the axial slice, and showed maximum values at the sagittal slice and coronal slice angles that are parallel to the Z-axis. With an oblique MPR image, MTF did not change with angle changes in the oblique sagittal slice plane, but in the oblique coronal slice plane, MTF increased as the tilt angle increased from the axial plane to the Z plane. As a result, we could evaluate the resolving power of a head 3D image by measuring the MTF of the axial image and sagittal image or the coronal image. (author)

  10. [Evaluation of the resolving power of different angles in MPR images of 16DAS-MDCT].

    Science.gov (United States)

    Kimura, Mikio; Usui, Junshi; Nozawa, Takeo

    2007-03-20

    In this study, we evaluated the resolving power of three-dimensional (3D) multiplanar reformation (MPR) images with various angles by using 16 data acquisition system multi detector row computed tomography (16DAS-MDCT) . We reconstructed the MPR images using data with a 0.75 mm slice thickness of the axial image in this examination. To evaluate resolving power, we used an original new phantom (RC phantom) that can be positioned at any slice angle in MPR images. We measured the modulation transfer function (MTF) by using the methods of measuring pre-sampling MTF, and used Fourier transform of image data of the square wave chart. The scan condition and image reconstruction condition that were adopted in this study correspond to the condition that we use for three-dimensional computed tomographic angiography (3D-CTA) examination of the head in our hospital. The MTF of MPR images showed minimum values at slice angles in parallel with the axial slice, and showed maximum values at the sagittal slice and coronal slice angles that are parallel to the Z-axis. With an oblique MPR image, MTF did not change with angle changes in the oblique sagittal slice plane, but in the oblique coronal slice plane, MTF increased as the tilt angle increased from the axial plane to the Z plane. As a result, we could evaluate the resolving power of a head 3D image by measuring the MTF of the axial image and sagittal image or the coronal image.

  11. Binary Pseudo-Random Gratings and Arrays for Calibration of Modulation Transfer Functions of Surface Profilometers

    Energy Technology Data Exchange (ETDEWEB)

    Barber, Samuel K.; Anderson, Erik D.; Cambie, Rossana; McKinney, Wayne R.; Takacs, Peter Z.; Stover, John C.; Voronov, Dmitriy L.; Yashchuk, Valeriy V.

    2009-09-11

    A technique for precise measurement of the modulation transfer function (MTF), suitable for characterization of a broad class of surface profilometers, is investigated in detail. The technique suggested in [Proc. SPIE 7077-7, (2007), Opt. Eng. 47(7), 073602-1-5 (2008)]is based on use of binary pseudo-random (BPR) gratings and arrays as standard MTF test surfaces. Unlike most conventional test surfaces, BPR gratings and arrays possess white-noise-like inherent power spectral densities (PSD), allowing the direct determination of the one- and two-dimensional MTF, respectively, with a sensitivity uniform over the entire spatial frequency range of a profiler. In the cited work, a one dimensional realization of the suggested method based on use of BPR gratings has been demonstrated. Here, a high-confidence of the MTF calibration technique is demonstrated via cross comparison measurements of a number of two dimensional BPR arrays using two different interferometric microscopes and a scatterometer. We also present the results of application of the experimentally determined MTF correction to the measurement taken with the MicromapTM-570 interferometric microscope of the surface roughness of a super-polished test mirror. In this particular case, without accounting for the instrumental MTF, the surface rms roughness over half of the instrumental spatial frequency bandwidth would be underestimated by a factor of approximately 1.4.

  12. Effects of replacing fish meal with soy protein concentrate and of DL-methionine supplementation in high-energy, extruded diets on the growth and nutrient utilization of rainbow trout, Oncorhynchus mykiss.

    Science.gov (United States)

    Mambrini, M; Roem, A J; Carvèdi, J P; Lallès, J P; Kaushik, S J

    1999-11-01

    Our objectives were to test the potential replacement of fish meal by soy protein concentrate (SPC) in high-energy, extruded diets fed to rainbow trout (Oncorhynchus mykiss) and to evaluate the efficiency of DL-methionine supplementation of soy-based diets. Groups of trout (initial BW 103 to 106 g) were fed to visual satiety with isonitrogenous (6.6% DM) high-energy (22.8 MJ/kg DM gross energy), extruded diets, in which fish meal was progressively replaced with SPC (0, 50, 75, and 100%). Three 100% SPC diets were formulated to be either unsupplemented or supplemented with DL-methionine, so that total methionine content was .8 or 1.0% of DM. The quality of the SPC source used was assessed by measuring the antitryptic and antigenic activities and the concentrations of the isoflavones daidzein and genistein. Apparent digestibility of the diets was determined using the indirect method. A growth trial was conducted over 90 d at a water temperature of 18 degrees C. In addition to body composition analysis, plasma amino acid concentrations, anti-soy protein antibodies in the serum, and isoflavone concentrations in the bile were measured. The SPC source tested exhibited low antitryptic and antigenic activities, but it contained high concentrations of isoflavones (1,990 and 5,903 ppm for daidzein and genistein, respectively). Protein digestibility was high (92%) and was unaffected either the proportion of SPC in the diet or by DL-methionine supplementation. This was also true for the availability of amino acids, except phenylalanine. Digestibility of lipid and energy was reduced by 19% when SPC totally replaced fish meal. Growth rate was reduced when more than 50% of the dietary protein was of soy origin (daily growth coefficient of 3.2 and 2.1% for the control and the unsupplemented 100% SPC diet, respectively). The effect on growth was mainly explained by a general decline in feed intake (13.7 and 12.0 g DM x kg BW(-1) x d(-1) for the control and the unsupplemented 100

  13. Evaluation of accountability measurements

    International Nuclear Information System (INIS)

    Cacic, C.G.

    1988-01-01

    The New Brunswick Laboratory (NBL) is programmatically responsible to the U.S. Department of Energy (DOE) Office of Safeguards and Security (OSS) for providing independent review and evaluation of accountability measurement technology in DOE nuclear facilities. This function is addressed in part through the NBL Safegaurds Measurement Evaluation (SME) Program. The SME Program utilizes both on-site review of measurement methods along with material-specific measurement evaluation studies to provide information concerning the adequacy of subject accountability measurements. This paper reviews SME Program activities for the 1986-87 time period, with emphasis on noted improvements in measurement capabilities. Continued evolution of the SME Program to respond to changing safeguards concerns is discussed

  14. An approach to measurement

    International Nuclear Information System (INIS)

    Gudder, S.P.

    1984-01-01

    A new approach to measurement theory is presented. The definition of measurement is motivated by direct laboratory procedures as they are carried out in practice. The theory is developed within the quantum logic framework. The work clarifies an important problem in the quantum logic approach; namely, where the Hilbert space comes from. The relationship between measurements and observables is considered, and a Hilbert space embedding theorem is presented. Charge systems are also discussed. (author)

  15. Decoherence and quantum measurements

    CERN Document Server

    Namiki, Mikio; Pascazio, Saverio

    1997-01-01

    The quantum measurement problem is one of the most fascinating and challenging topics in physics both theoretically and experimentally. It involves deep questions and the use of very sophisticated and elegant techniques. After analyzing the fundamental principles of quantum mechanics and of the Copenhagen interpretation, this book reviews the most important approaches to the measurement problem and rigorously reformulates the "collapse of the wave function" by measurement, as a dephasing process quantitatively characterized by an order parameter (called the decoherence parameter), according to

  16. Betatron tune measurement

    International Nuclear Information System (INIS)

    Dinev, D.

    2001-01-01

    On the basis of the comparative review of the methods for the betatron tune measurement in cyclic accelerators of synchrotrons type, the research of these methods is carried out from the point of view of their applicability to Nuclotron. Both methods using measurement of the statistical fluctuations of the beam current (Schottky noise) and methods using coherent beam excitation have been discussed. The emphasis is on the final results of importance for the tune measurement practice. Signal processing is briefly discussed too

  17. Broadband radiometric LED measurements

    Science.gov (United States)

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-09-01

    At present, broadband radiometric LED measurements with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed.

  18. Radioisotope measurement system

    International Nuclear Information System (INIS)

    Villanueva Ruibal, Jose

    2007-01-01

    A radioisotope measurement system installed at L.M.R. (Ezeiza Atomic Center of CNEA) allows the measurement of nuclear activity from a wide range of radioisotopes. It permits to characterize a broad range of radioisotopes at several activity levels. The measurement hardware as well as the driving software have been developed and constructed at the Dept. of Instrumentation and Control. The work outlines the system's conformation and its operating concept, describes design characteristics, construction and the error treatment, comments assay results and supplies use advices. Measuring tests carried out employing different radionuclides confirmed the system performing satisfactorily and with friendly operation. (author) [es

  19. Aperture area measurement facility

    Data.gov (United States)

    Federal Laboratory Consortium — NIST has established an absolute aperture area measurement facility for circular and near-circular apertures use in radiometric instruments. The facility consists of...

  20. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Healthy Weight Breastfeeding Micronutrient Malnutrition State and Local Programs Measuring Physical Activity Intensity Recommend on Facebook Tweet Share Compartir For more help with what ...

  1. Atmospheric Measurements Laboratory (AML)

    Data.gov (United States)

    Federal Laboratory Consortium — The Atmospheric Measurements Laboratory (AML) is one of the nation's leading research facilities for understanding aerosols, clouds, and their interactions. The AML...

  2. Semiconductor Laser Measurements Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Semiconductor Laser Measurements Laboratory is equipped to investigate and characterize the lasing properties of semiconductor diode lasers. Lasing features such...

  3. The attribute measurement technique

    International Nuclear Information System (INIS)

    MacArthur, Duncan W.; Langner, Diana; Smith, Morag; Thron, Jonathan; Razinkov, Sergey; Livke, Alexander

    2010-01-01

    Any verification measurement performed on potentially classified nuclear material must satisfy two seemingly contradictory constraints. First and foremost, no classified information can be released. At the same time, the monitoring party must have confidence in the veracity of the measurement. An information barrier (IB) is included in the measurement system to protect the potentially classified information while allowing sufficient information transfer to occur for the monitoring party to gain confidence that the material being measured is consistent with the host's declarations, concerning that material. The attribute measurement technique incorporates an IB and addresses both concerns by measuring several attributes of the nuclear material and displaying unclassified results through green (indicating that the material does possess the specified attribute) and red (indicating that the material does not possess the specified attribute) lights. The attribute measurement technique has been implemented in the AVNG, an attribute measuring system described in other presentations at this conference. In this presentation, we will discuss four techniques used in the AVNG: (1) the 1B, (2) the attribute measurement technique, (3) the use of open and secure modes to increase confidence in the displayed results, and (4) the joint design as a method for addressing both host and monitor needs.

  4. Measuring School Contexts

    Directory of Open Access Journals (Sweden)

    Chandra L. Muller PhD

    2015-11-01

    Full Text Available This article describes issues in measuring school contexts with an eye toward understanding students’ experiences and outcomes. I begin with an overview of the conceptual underpinnings related to measuring contexts, briefly describe the initiatives at the National Center for Education Statistics to measure school contexts, and identify possible gaps in those initiatives that if filled could provide valuable new data for researchers. Next, I discuss new approaches and opportunities for measurement, and special considerations related to diverse populations and youth development. I conclude with recommendations for future priorities.

  5. Luminosity measurement at AMY

    International Nuclear Information System (INIS)

    Kurihara, Y.

    1995-01-01

    A precise measurement of a luminosity is required by experiments with high statistics. The largest sources of a systematic error of a luminosity measurement are an alignment of the tube chambers which measure a polar angle of Bhabha events and a higher order correction for the Bhabha cross section calculation. We describe a resent study for these uncertainties and how to reduce the systematic errors from these sources. The total systematic error of the luminosity measurement of 1.8% can be reduced to 1.0% by this study. (author)

  6. Young Measures and Compactness in Measure Spaces

    CERN Document Server

    Florescu, Liviu C

    2012-01-01

    Many problems in science can be formulated in the language of optimization theory, in which case an optimal solution or the best response to a particular situation is required. In situations of interest, such classical optimal solutions are lacking, or at least, the existence of such solutions is far from easy to prove. So, non-convex optimization problems may not possess a classical solution because approximate solutions typically show rapid oscillations. This phenomenon requires the extension of such problems' solution often constructed by means of Young measures. This book is written to int

  7. Regularities of Multifractal Measures

    Indian Academy of Sciences (India)

    First, we prove the decomposition theorem for the regularities of multifractal Hausdorff measure and packing measure in R R d . This decomposition theorem enables us to split a set into regular and irregular parts, so that we can analyze each separately, and recombine them without affecting density properties. Next, we ...

  8. Similarity Measure of Graphs

    Directory of Open Access Journals (Sweden)

    Amine Labriji

    2017-07-01

    Full Text Available The topic of identifying the similarity of graphs was considered as highly recommended research field in the Web semantic, artificial intelligence, the shape recognition and information research. One of the fundamental problems of graph databases is finding similar graphs to a graph query. Existing approaches dealing with this problem are usually based on the nodes and arcs of the two graphs, regardless of parental semantic links. For instance, a common connection is not identified as being part of the similarity of two graphs in cases like two graphs without common concepts, the measure of similarity based on the union of two graphs, or the one based on the notion of maximum common sub-graph (SCM, or the distance of edition of graphs. This leads to an inadequate situation in the context of information research. To overcome this problem, we suggest a new measure of similarity between graphs, based on the similarity measure of Wu and Palmer. We have shown that this new measure satisfies the properties of a measure of similarities and we applied this new measure on examples. The results show that our measure provides a run time with a gain of time compared to existing approaches. In addition, we compared the relevance of the similarity values obtained, it appears that this new graphs measure is advantageous and  offers a contribution to solving the problem mentioned above.

  9. Measures of Pleasures

    NARCIS (Netherlands)

    S.J. Magala (Slawomir)

    2002-01-01

    textabstractMeasuring culture originated in cultural anthropology, but all social sciences contributed to comparative cultural studies. Tracing critical approaches towards a measurement of cultural values one is bound to strip the biases and stereotypes bare and to invade numerous academic fiefs.

  10. Measuring Mobile Phone Use

    DEFF Research Database (Denmark)

    Boase, Jeff; Ling, Richard

    2013-01-01

    In this paper we examine how well two types of self-report measures adequately operationalize frequency of mobile phone use by comparing them to server log data. Our self-report measures of voice and SMS text messaging activity are drawn from a nationally representative survey of adults living...

  11. Mechanical Measurements Laboratory

    CERN Multimedia

    Maximilien Brice

    2007-01-01

    The CERN mechanical measurements team check the sensors on one of the ATLAS inner detector end-caps using high precision measurement equipment. Remote checks like this must be made on these sensitive detector components before they can be transported to make sure that all systems are working correctly.

  12. Auditing measurement control programs

    International Nuclear Information System (INIS)

    Roberts, F.P.; Brouns, R.J.

    1979-10-01

    Requirements and a general procedure for auditing measurement control programs used in special nuclear material accounting are discussed. The areas of measurement control that need to be examined are discussed and a suggested checklist is included to assist in the preparation and performance of the audit

  13. Measuring Relational Reasoning

    Science.gov (United States)

    Alexander, Patricia A.; Dumas, Denis; Grossnickle, Emily M.; List, Alexandra; Firetto, Carla M.

    2016-01-01

    Relational reasoning is the foundational cognitive ability to discern meaningful patterns within an informational stream, but its reliable and valid measurement remains problematic. In this investigation, the measurement of relational reasoning unfolded in three stages. Stage 1 entailed the establishment of a research-based conceptualization of…

  14. Measurement of surface roughness

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo

    This document is used in connection with two 3 hours laboratory exercises that are part of the course GEOMETRICAL METROLOGY AND MACHINE TESTING. The laboratories include a demonstration of the function of roughness measuring instruments plus a series of exercises illustrating roughness measurement...

  15. Measuring regional authority

    NARCIS (Netherlands)

    Marks, G.W.; Hooghe, E.A.E.B.; Schakel, A.H.

    2008-01-01

    This article sets out a conceptual basis for measuring regional authority and engages basic measurement issues. Regional authority is disaggregated into two domains (self-rule and shared rule) and these are operationalised in eight dimensions. The article concludes by examining the robustness of

  16. Meteorological measurements. Chapter 3

    Science.gov (United States)

    David Y. Hollinger

    2008-01-01

    Environmental measurements are useful for detecting climatic trends, understanding how the environment influences biological processes, and as input to ecosystem models. Landscape-scale monitoring requires a suite of environmental measures for all of these purposes, including air and soil temperature, humidity, wind speed, precipitation and soil moisture, and different...

  17. Metrology Measurement Capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Glen E. Gronniger

    2007-10-02

    This document contains descriptions of Federal Manufacturing & Technologies (FM&T) Metrology capabilities, traceability flow charts, and the measurement uncertainty of each measurement capability. Metrology provides NIST traceable precision measurements or equipment calibration for a wide variety of parameters, ranges, and state-of-the-art uncertainties. Metrology laboratories conform to the requirements of the Department of Energy Development and Production Manual Chapter 13.2, ANSI/ISO/IEC ANSI/ISO/IEC 17025:2005, and ANSI/NCSL Z540-1. FM&T Metrology laboratories are accredited by NVLAP for the parameters, ranges, and uncertainties listed in the specific scope of accreditation under NVLAP Lab code 200108-0. See the Internet at http://ts.nist.gov/Standards/scopes/2001080.pdf. These parameters are summarized. The Honeywell Federal Manufacturing & Technologies (FM&T) Metrology Department has developed measurement technology and calibration capability in four major fields of measurement: (1) Mechanical; (2) Environmental, Gas, Liquid; (3) Electrical (DC, AC, RF/Microwave); and (4) Optical and Radiation. Metrology Engineering provides the expertise to develop measurement capabilities for virtually any type of measurement in the fields listed above. A strong audit function has been developed to provide a means to evaluate the calibration programs of our suppliers and internal calibration organizations. Evaluation includes measurement audits and technical surveys.

  18. Low Absorbance Measurements

    Science.gov (United States)

    Harris, T. D.; Williams, A. M.

    1983-10-01

    The application of low absorption measurements to dilute solute determination requires specific instrumental characteristics. The use of laser intracavity absorption and thermal lens calorimetry to measure concentration is shown. The specific operating parameters that determine sensitivity are delineated along with the limits different measurement strategies impose. Finally areas of improvement in components that would result in improve sensitivity, accuracy, and reliability are discussed. During the past decade, a large number of methods have been developed for measuring the light absorbed by transparent materials. These include measurements on gases, liquids, and solids. The activity has been prompted by a variety of applications and a similar variety of disciplines. In Table 1 some representative examples of these methods is shown along with their published detection limits.1 It is clear that extraordinarily small absorbances can be measured. Most of the methods can be conveniently divided into two groups. These groups are those that measure the transmission of the sample and those that measure the light absorbed by the sample. The light absorbed methods are calorimetric in character. The advantages and disadvantages of each method varies depending on the principal application for which they were developed. The most prevalent motivation has been to characterize the bulk optical properties of transparent materials. Two examples are the development of extremely transparent glasses for use as fiber optic materials and the development of substrates for high power laser operation.

  19. Dynamics via measurability

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available Generators f for σ -algebras can be used to view the dynamics of an invertible measurable transformation T in terms of the range values of f ∘ T . Such generators are the norm rather than the exception. Related measurable and quantitative methods of estimating a function from the behavior of ergodic averages are also discussed.

  20. Global Precipitation Measurement Poster

    Science.gov (United States)

    Azarbarzin, Art

    2010-01-01

    This poster presents an overview of the Global Precipitation Measurement (GPM) constellation of satellites which are designed to measure the Earth's precipitation. It includes the schedule of launches for the various satellites in the constellation, and the coverage of the constellation, It also reviews the mission capabilities, and the mission science objectives.

  1. Measuring internet skills

    NARCIS (Netherlands)

    van Deursen, Alexander Johannes Aloysius Maria; van Dijk, Johannes A.G.M.

    2010-01-01

    Research that considers Internet skills often lacks theoretical justifications and does not go beyond basic button knowledge. There is a strong need for a measurement framework that can guide future research. In this article, operational definitions for measuring Internet skills are proposed,

  2. Measurement in Sustainable Building

    DEFF Research Database (Denmark)

    Hale, Lara

    2018-01-01

    Measurement is a necessary aspect of planning and constructing buildings. However, recent attempts to integrate the social dimension of sustainable building into building design and specifications demand measurement of non-technical qualities, such as well-being. The Active House Alliance, in lieu...... and continued provision of sustainable buildings to market demand....

  3. Measuring bothersome menopausal symptoms

    DEFF Research Database (Denmark)

    Lund, Kamma Sundgaard; Siersma, Volkert Dirk; Christensen, Karl Bang

    2018-01-01

    BACKGROUND: The experience of menopausal symptoms is common and an adequate patient-reported outcome measure is crucial in studies where women are treated for these symptoms. The aims of this study were to identify a patient-reported outcome measure for bothersome menopausal symptoms and, in the ...

  4. Measuring Authoritative Teaching

    Science.gov (United States)

    Ertesvag, Sigrun K.

    2011-01-01

    High quality measurements are important to evaluate interventions. The study reports on the development of a measurement to investigate authoritative teaching understood as a two-dimensional construct of warmth and control. Through the application of confirmatory factor analysis (CFA) and structural equation modelling (SEM) the factor structure…

  5. Measuring innovative work behaviour

    NARCIS (Netherlands)

    de Jong, J.; den Hartog, D.

    2010-01-01

    Both scientists and practitioners emphasize the importance of innovative work behaviour (IWB) of individual employees for organizational success, but the measurement of IWB is still at an evolutionary stage. This article is concerned with developed a measure of IWB with four potential dimensions:

  6. Measuring News Media Literacy

    Science.gov (United States)

    Maksl, Adam; Ashley, Seth; Craft, Stephanie

    2015-01-01

    News media literacy refers to the knowledge and motivations needed to identify and engage with journalism. This study measured levels of news media literacy among 500 teenagers using a new scale measure based on Potter's model of media literacy and adapted to news media specifically. The adapted model posits that news media literate individuals…

  7. Measures of Biochemical Sociology

    Science.gov (United States)

    Snell, Joel; Marsh, Mitchell

    2008-01-01

    In a previous article, the authors introduced a new sub field in sociology that we labeled "biochemical sociology." We introduced the definition of a sociology that encompasses sociological measures, psychological measures, and biological indicators Snell & Marsh (2003). In this article, we want to demonstrate a research strategy that would assess…

  8. Measures of Student Growth

    Science.gov (United States)

    Texas Education Agency, 2016

    2016-01-01

    Beginning in the 2017-2018 school year, appraisal systems in Texas, whether the state-recommended system or a locally developed system, will need to include a measure of student growth at the individual teacher level. Student growth measures how much a student progresses academically during his or her time with a particular teacher. It takes into…

  9. Measuring irradiation creep

    International Nuclear Information System (INIS)

    Pelah, I.

    1981-03-01

    Simulation of fusion-neutron induced damage by beams of light ions is discussed. It is suggested that accelerated creep measurements to determine ''end of life'' of materials may be done by the application of thermal treatment and thermal creep measurements. (author)

  10. Aerial measurements in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Winkelmann, I.; Thomas, M.; Buchroeder, H.; Brummer, C. [Federal Office for Radiation Protection, Berlin (Germany); Carloff, G. [German Federal Border Police, Grenzschutz-Fliegergruppe, Sankt Augustin (Germany)

    1997-12-31

    Aerial measurements were performed to determine the {sup 137}Cs soil contamination in a given region to detect unknown radiation sources and to assess their activity. For these measurements a computerized gamma ray spectrometer, equipped with a high purity Ge-semiconductor detector and a 12 l volume Nal(Tl)-detector was used. HPGe-detector measurements from different altitudes over area I were done to test and re-calibrate the aerial measuring system. The known {sup 137}Cs contamination of (50.7 {+-} 5.2) kBq m{sup -2} could be confirmed by the measured value of (57 {+-} 10) kBq m{sup -2}. the Nal(Tl)-detector was re-calibrated at that site for further {sup 137}Cs measurements over area II. The area II was surveyed from an altitude of about 70 m and at a parallel line distance of 150 m at an flying speed of 100 km h{sup -1} to determine the {sup 137}Cs soil contamination. The measuring time was two seconds for the Nal(Tl)-detector. For the spectra measured with the HPGe-detector, a measuring time of 30 s each was chosen. From the Nal(Tl)-measurements, a mean {sup 137}Cs value of (60 {+-} 20) kBq m{sup -2} was determined with a maximum value of 90 kBq m{sup -2}. The corresponding values measured by HPGe-detector were (70 {+-} 20) kBq m{sup -2} and 120 kBq m{sup -2}, respectively. For the evaluation of the HPGe-spectra a depth distribution parameter {alpha}/{rho} = (0.44 {+-} 0.21) cm{sup 2} g{sup -1} for {sup 137}Cs was used measured from soil samples. From data measured with the Nal(Tl)-detector during flights over area III, three{sup 60}Co-sources and one {sup 137}Cs source could be detected, localized and their activity assessed. By HPGe-detector measurements, only scattered {sup 192}lr radiation was registered. (au).

  11. Aerial measurements in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Winkelmann, I; Thomas, M; Buchroeder, H; Brummer, C [Federal Office for Radiation Protection, Berlin (Germany); Carloff, G [German Federal Border Police, Grenzschutz-Fliegergruppe, Sankt Augustin (Germany)

    1998-12-31

    Aerial measurements were performed to determine the {sup 137}Cs soil contamination in a given region to detect unknown radiation sources and to assess their activity. For these measurements a computerized gamma ray spectrometer, equipped with a high purity Ge-semiconductor detector and a 12 l volume Nal(Tl)-detector was used. HPGe-detector measurements from different altitudes over area I were done to test and re-calibrate the aerial measuring system. The known {sup 137}Cs contamination of (50.7 {+-} 5.2) kBq m{sup -2} could be confirmed by the measured value of (57 {+-} 10) kBq m{sup -2}. the Nal(Tl)-detector was re-calibrated at that site for further {sup 137}Cs measurements over area II. The area II was surveyed from an altitude of about 70 m and at a parallel line distance of 150 m at an flying speed of 100 km h{sup -1} to determine the {sup 137}Cs soil contamination. The measuring time was two seconds for the Nal(Tl)-detector. For the spectra measured with the HPGe-detector, a measuring time of 30 s each was chosen. From the Nal(Tl)-measurements, a mean {sup 137}Cs value of (60 {+-} 20) kBq m{sup -2} was determined with a maximum value of 90 kBq m{sup -2}. The corresponding values measured by HPGe-detector were (70 {+-} 20) kBq m{sup -2} and 120 kBq m{sup -2}, respectively. For the evaluation of the HPGe-spectra a depth distribution parameter {alpha}/{rho} = (0.44 {+-} 0.21) cm{sup 2} g{sup -1} for {sup 137}Cs was used measured from soil samples. From data measured with the Nal(Tl)-detector during flights over area III, three{sup 60}Co-sources and one {sup 137}Cs source could be detected, localized and their activity assessed. By HPGe-detector measurements, only scattered {sup 192}lr radiation was registered. (au).

  12. Dose measurements in mammography

    International Nuclear Information System (INIS)

    Kainberger, F.; Kallinger, W.

    1977-01-01

    Dose measurements at the mamma during mammography were carried out in the form of direct measurement with thermoluminescent dosimetry. Measurement was done for the in- and outcoming doses at the mamma, the dose exposure of the sternal region and the scattered rays above the symphysis, the latter as parameter for the genetic radiation exposure. As expected, the dose of the smooth radiation used for mammography showed a strong decrease at the outcome point in comparison with the income point. Surprisingly high was the scattered radiation in the sternal region. A corresponding protection by lead plates could be taken into consideration. Extremely low is the scattered radiation above the symphysis. Even measurements with the very sensitive calcium fluoride dosimeters did not reveal any practically important dose in the symphysis region. Most measurement values remained below the determinable dose of 0.3mR. Some maximal values varied in the range of 3-1 mR. (orig.) [de

  13. Solar cell efficiency measurements

    International Nuclear Information System (INIS)

    Ostoja, P.

    1989-01-01

    Solar cells (and solar modules) have to be tested for their performance by means of sound reliable measurement procedures. The need for such measurements arises at various stages of research, of production, and of photovoltaic systems sizing and dimensioning. In fact, accurate measurements are necessary to the researcher, who studies new materials and new processes, to the manufacturer, who has to control his product and, finally, to the user, who needs sound measurements, in order to be in a position to make effective decisions about what kink of product will be needed and with what critical characteristics. In short, standard measurements that allow cells and modules to be characterized serve as a common language, allowing effective communication about products and requirements. 3 refs

  14. Measurement environments and testing

    Science.gov (United States)

    Marvin, A. C.

    1991-06-01

    The various methods used to assess both the emission (interference generation) performance of electronic equipment and the immunity of electronic equipment to external electromagnetic interference are described. The measurement methods attempt to simulate realistic operating conditions for the equipment being tested, yet at the same time they must be repeatable and practical to operate. This has led to the development of a variety of test methods, each of which has its limitations. Concentration is on the most common measurement methods such as open-field test sites, screened enclosures and transverse electromagnetic (TEM) cells. The physical justification for the methods, their limitations, and measurement precision are described. Ways of relating similar measurements made by different methods are discussed, and some thoughts on future measurement improvements are presented.

  15. Standardization of radon measurements

    International Nuclear Information System (INIS)

    Matuszek, J.M.; Hutchinson, J.A.; Lance, B.H.; Virgil, M.G.; Mahoney, R.J.

    1988-01-01

    Radon escaping from soil into homes appears to present the single greatest source of radiation exposure that most people will ever face. Measurement protocols for the relatively inert gas inextricably link the method of collection with the counting of the specimen. The most commonly used methods depend on the measurement of dislocation sites on plastic α-track detectors or on the adsorption of radon onto activated charcoal for subsequent counting of the γ-rays produced by decay of the radon progeny. The uncertainties inherent to the radon-measurement methods used commercially in the United States are far greater than those for measurements of other environmental radionuclides. The results of this preliminary study raise doubts as to whether existing proficiency-testing programs can provide assurance that radon-measurement methods are representative of actual conditions in any dwelling. 17 refs., 1 figs., 4 tabs

  16. Measurement uncertainty and probability

    CERN Document Server

    Willink, Robin

    2013-01-01

    A measurement result is incomplete without a statement of its 'uncertainty' or 'margin of error'. But what does this statement actually tell us? By examining the practical meaning of probability, this book discusses what is meant by a '95 percent interval of measurement uncertainty', and how such an interval can be calculated. The book argues that the concept of an unknown 'target value' is essential if probability is to be used as a tool for evaluating measurement uncertainty. It uses statistical concepts, such as a conditional confidence interval, to present 'extended' classical methods for evaluating measurement uncertainty. The use of the Monte Carlo principle for the simulation of experiments is described. Useful for researchers and graduate students, the book also discusses other philosophies relating to the evaluation of measurement uncertainty. It employs clear notation and language to avoid the confusion that exists in this controversial field of science.

  17. Calibration of a modified temperature-light intensity logger for quantifying water electrical conductivity

    Science.gov (United States)

    Gillman, M. A.; Lamoureux, S. F.; Lafrenière, M. J.

    2017-09-01

    The Stream Temperature, Intermittency, and Conductivity (STIC) electrical conductivity (EC) logger as presented by Chapin et al. (2014) serves as an inexpensive (˜50 USD) means to assess relative EC in freshwater environments. This communication demonstrates the calibration of the STIC logger for quantifying EC, and provides examples from a month long field deployment in the High Arctic. Calibration models followed multiple nonlinear regression and produced calibration curves with high coefficient of determination values (R2 = 0.995 - 0.998; n = 5). Percent error of mean predicted specific conductance at 25°C (SpC) to known SpC ranged in magnitude from -0.6% to 13% (mean = -1.4%), and mean absolute percent error (MAPE) ranged from 2.1% to 13% (mean = 5.3%). Across all tested loggers we found good accuracy and precision, with both error metrics increasing with increasing SpC values. During 10, month-long field deployments, there were no logger failures and full data recovery was achieved. Point SpC measurements at the location of STIC loggers recorded via a more expensive commercial electrical conductivity logger followed similar trends to STIC SpC records, with 1:1.05 and 1:1.08 relationships between the STIC and commercial logger SpC values. These results demonstrate that STIC loggers calibrated to quantify EC are an economical means to increase the spatiotemporal resolution of water quality investigations.

  18. Optical, geometric and thermal study for solar parabolic concentrator efficiency improvement under Tunisia environment: A case study

    International Nuclear Information System (INIS)

    Skouri, Safa; Ben Salah, Mohieddine; Bouadila, Salwa; Balghouthi, Moncef; Ben Nasrallah, Sassi

    2013-01-01

    Highlights: • Design and construction of solar parabolic concentrator. • Photogrammetry study of SPC. • Slope error and optical efficiency of SPC. • Reflector materials of SPC. • Programmed tracking solar system. - Abstract: Renewable energy generation is becoming more prevalent today. It is relevant to consider that solar concentration technologies contribute to provide a real alternative to the consumption of fossil fuels. The purpose of this work is the characterization of a solar parabolic solar concentrator (SPC) designed, constructed and tested in the Research and Technologies Centre of Energy in Tunisia (CRTEn) in order to improve the performance of the system. Photogrammetry measurement used to analyze the slope errors and to determine hence determining the geometric deformation of the SPC system, which presents an average slope error around 0.0002 and 0.0073 mrad respectively in the center and in the extremities. An optimization of the most performed reflector material has been done by an experimental study of three types of reflectors. A two axes programmed tracking system realized, used and tested in this study. An experimental study is carried out to evaluate the solar parabolic concentrator thermal efficiency after the mechanical and the optical SPC optimization. The thermal energy efficiency varies from 40% to 77%, the concentrating system reaches an average concentration factor around 178

  19. ORDERED WEIGHTED DISTANCE MEASURE

    Institute of Scientific and Technical Information of China (English)

    Zeshui XU; Jian CHEN

    2008-01-01

    The aim of this paper is to develop an ordered weighted distance (OWD) measure, which is thegeneralization of some widely used distance measures, including the normalized Hamming distance, the normalized Euclidean distance, the normalized geometric distance, the max distance, the median distance and the min distance, etc. Moreover, the ordered weighted averaging operator, the generalized ordered weighted aggregation operator, the ordered weighted geometric operator, the averaging operator, the geometric mean operator, the ordered weighted square root operator, the square root operator, the max operator, the median operator and the min operator axe also the special cases of the OWD measure. Some methods depending on the input arguments are given to determine the weights associated with the OWD measure. The prominent characteristic of the OWD measure is that it can relieve (or intensify) the influence of unduly large or unduly small deviations on the aggregation results by assigning them low (or high) weights. This desirable characteristic makes the OWD measure very suitable to be used in many actual fields, including group decision making, medical diagnosis, data mining, and pattern recognition, etc. Finally, based on the OWD measure, we develop a group decision making approach, and illustrate it with a numerical example.

  20. DOAS urban pollution measurements

    International Nuclear Information System (INIS)

    Stevens, R.K.; Vossler, T.L.

    1991-01-01

    This paper reports that during July and August of 1990, a differential optical absorption spectrometer (DOAS) made by OPSIS Inc., was used to measure gaseous air pollutants over three separate open paths in Atlanta, GA. Over path 1 and path 2, ozone (O 3 ), sulfur dioxide (SO 2 ), nitrogen dioxide (NO 2 ), nitrous acid (HNO 2 ), formaldehyde (HCHO), benzene, toluene, and o-xylene were measured. Nitric oxide (NO) and ammonia (NH 3 ) were monitored over path 3 (143 m). The data quality and data capture depended on the compound being measured and the path over which it was measured. Data quality criteria for each compound were chosen such that the average relative standard deviation would be less than 25%. Data capture ranged from 43% for o-xylene for path 1 to 95% for ozone for path 2. Benzene, toluene, and o-xylene concentrations measured over path 2, which crossed over an interstate highway, were higher than concentrations measured over path 1, implicating emissions from vehicles on the highway as a significant source of these compounds. Federal Reference Method (FRM) instruments were located near the DOAS light receivers and measurements of O 3 , NO 2 , and NO were made concurrently with the DOAS. Correlation coefficients greater than 0.85 were obtained between the DOAS and FRM's; however, there was a difference between the mean values obtained by the two methods for O 3 and NO. A gas chromatograph for measuring volatile organic compounds was operated next to the FRM's. Correlation coefficients of about 0.66 were obtained between the DOAS and GC measurements of benzene and o-xylene

  1. Mathematics and Measurement.

    Science.gov (United States)

    Boisvert, R F; Donahue, M J; Lozier, D W; McMichael, R; Rust, B W

    2001-01-01

    In this paper we describe the role that mathematics plays in measurement science at NIST. We first survey the history behind NIST's current work in this area, starting with the NBS Math Tables project of the 1930s. We then provide examples of more recent efforts in the application of mathematics to measurement science, including the solution of ill-posed inverse problems, characterization of the accuracy of software for micromagnetic modeling, and in the development and dissemination of mathematical reference data. Finally, we comment on emerging issues in measurement science to which mathematicians will devote their energies in coming years.

  2. Nuclear lifetime measurement

    International Nuclear Information System (INIS)

    Guillaume, Georges

    Three direct techniques of lifetime measurement are emphasized: electronic methods and two methods based on the Doppler effect (the recoil distance methods or RDM, the Doppler shift attenuation methods or DSAM). Said direct methods are concerned with the direct measurement of the radioactive decay constants of nuclear excited states. They allow lifetimes of nucleus bound states whose deexcitations occur by electromagnetic transitions, to be determined. Other methods for measuring lifetimes are also examined: microwave techniques and those involving the blocking effect in crystals (direct methods) and also various indirect methods of obtaining lifetimes (γ resonance scattering, capture reactions, inelastic electron and nucleus scattering, and Coulomb deexcitation) [fr

  3. Spectroelectrochemical Instrument Measures TOC

    Science.gov (United States)

    Kounaves, Sam

    2011-01-01

    A spectroelectrochemical instrument has been developed for measuring the total organic carbon (TOC) content of an aqueous solution. Measurements of TOC are frequently performed in environmental, clinical, and industrial settings. Until now, techniques for performing such measurements have included, various ly, the use of hazardous reagents, ultraviolet light, or ovens, to promote reactions in which the carbon contents are oxidized. The instrument now being developed is intended to be a safer, more economical means of oxidizing organic carbon and determining the TOC levels of aqueous solutions and for providing a low power/mass unit for use in planetary missions.

  4. Measurement of weak radioactivity

    CERN Document Server

    Theodorsson , P

    1996-01-01

    This book is intended for scientists engaged in the measurement of weak alpha, beta, and gamma active samples; in health physics, environmental control, nuclear geophysics, tracer work, radiocarbon dating etc. It describes the underlying principles of radiation measurement and the detectors used. It also covers the sources of background, analyzes their effect on the detector and discusses economic ways to reduce the background. The most important types of low-level counting systems and the measurement of some of the more important radioisotopes are described here. In cases where more than one type can be used, the selection of the most suitable system is shown.

  5. Measurement of plasma parameters

    International Nuclear Information System (INIS)

    1999-01-01

    The physics issues of the measurements of the plasma properties necessary to provide both the control and science data for achieving the goals of the ITER device are discussed. The assessment of the requirements for these measurements is first discussed, together with priorities that relate to the experimental program. Subsequently, some of the proposed measurement techniques, the plasma diagnostics, are described with particular emphasis on their implementation on ITER and their capability to meet the requirements. A judgement on the present status of the diagnostic program on ITER is provided with some indication of the research and development program necessary to demonstrate viability of techniques or their implementation. (author)

  6. Measurements of smoke

    International Nuclear Information System (INIS)

    Bakker, F.P.; Geusebroek, M.; Kos, G.P.A.; Van Egmond, B.F.

    2005-02-01

    For Euromate measurements are performed at 21 December 2004, in order to characterize their new smoking chamber 'rookabri S+G2'. At location gas analysis and particle measurements are performed. A number of off-line sampled organic smoke trace compounds were analysed at our laboratory. Sampling and measurements were performed at different smoke levels with 0, 2, 4 and 6 smoking volunteers. The smoke-abri is a specially designed space for smokers in which the environment is cleared from tobacco smoke and odor [nl

  7. Refractive index based measurements

    DEFF Research Database (Denmark)

    2014-01-01

    In a method for performing a refractive index based measurement of a property of a fluid such as chemical composition or temperature by observing an apparent angular shift in an interference fringe pattern produced by back or forward scattering interferometry, ambiguities in the measurement caused...... by the apparent shift being consistent with one of a number of numerical possibilities for the real shift which differ by 2n are resolved by combining measurements performed on the same sample using light paths therethrough of differing lengths....

  8. Cardiac output measurement

    Directory of Open Access Journals (Sweden)

    Andreja Möller Petrun

    2014-02-01

    Full Text Available In recent years, developments in the measuring of cardiac output and other haemodynamic variables are focused on the so-called minimally invasive methods. The aim of these methods is to simplify the management of high-risk and haemodynamically unstable patients. Due to the need of invasive approach and the possibility of serious complications the use of pulmonary artery catheter has decreased. This article describes the methods for measuring cardiac output, which are based on volume measurement (Fick method, indicator dilution method, pulse wave analysis, Doppler effect, and electrical bioimpedance.

  9. RF impedance measurement calibration

    International Nuclear Information System (INIS)

    Matthews, P.J.; Song, J.J.

    1993-01-01

    The intent of this note is not to explain all of the available calibration methods in detail. Instead, we will focus on the calibration methods of interest for RF impedance coupling measurements and attempt to explain: (1). The standards and measurements necessary for the various calibration techniques. (2). The advantages and disadvantages of each technique. (3). The mathematical manipulations that need to be applied to the measured standards and devices. (4). An outline of the steps needed for writing a calibration routine that operated from a remote computer. For further details of the various techniques presented in this note, the reader should consult the references

  10. Parameter measurement of target

    International Nuclear Information System (INIS)

    Gao Dangzhong

    2001-01-01

    The progress of parameter measurement of target (ICF-15) in 1999 are presented, including the design and contract of the microsphere equator profiler, the precise air bearing manufacturing, high-resolution X-ray image of multi-layer shells and the X-ray photos processed with special image and data software, some plastic shells measured in precision of 0.3 μm, the high-resolution observation and photograph system of 'dew-point method', special fixture of target and its temperature distribution measuring, the dew-point temperature and fuel gas pressure of shells measuring with internal pressure of 5 - 15 (x10 5 ) Pa D 2 and wall thickness of 1.5∼3 μm

  11. Bioelectric Signal Measuring System

    Science.gov (United States)

    Guadarrama-Santana, A.; Pólo-Parada, L.; García-Valenzuela, A.

    2015-01-01

    We describe a low noise measuring system based on interdigitated electrodes for sensing bioelectrical signals. The system registers differential voltage measurements in order of microvolts. The base noise during measurements was in nanovolts and thus, the sensing signals presented a very good signal to noise ratio. An excitation voltage of 1Vrms with 10 KHz frequency was applied to an interdigitated capacitive sensor without a material under test and to a mirror device simultaneously. The output signals of both devices was then subtracted in order to obtain an initial reference value near cero volts and reduce parasitic capacitances due to the electronics, wiring and system hardware as well. The response of the measuring system was characterized by monitoring temporal bioelectrical signals in real time of biological materials such as embryo chicken heart cells and bovine suprarenal gland cells.

  12. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... using relative intensity, people pay attention to how physical activity affects their heart rate and breathing. The talk test is a simple way to measure relative intensity. ...

  13. Measuring Entrepreneurial Ecosystems

    NARCIS (Netherlands)

    Stam, F.C.

    How can entrepreneurial ecosystems and productive entrepreneurship can be traced empirically and how is entrepreneurship related to entrepreneurial ecosystems. The analyses in this chapter show the value of taking a systems view on the context of entrepreneurship. We measure entrepreneurial

  14. Dilepton Measurements with CERES

    Energy Technology Data Exchange (ETDEWEB)

    Marin,A.; Rehak, P. et al.

    2007-07-09

    We report on dilepton measurements for central Pb on Au collisions at the top CERN SPS energy with the upgraded CERES experiment. The dilepton mass spectrum of 2000 data with improved mass resolution shows an enhancement over the expectation from hadron decays that is well described by a model including a strong broadening of the {rho} spectral function. The measured excess yield excludes the dropping mass scenario. We also report on the {phi} meson measured simultaneously both in the K{sup +}K{sup -} and in the dilepton decay channel for the first time in high energy heavy-ion collisions. An excellent agreement is found between the rapidity densities and the shape of the measured transverse momentum spectrum. The data rule out a possible enhancement of the {phi} yield in the leptonic over hadronic channel by a factor larger than 1.6 at 95% CL. CERES results are in agreement with NA49 results.

  15. Measure Evaluation Dataverse

    Data.gov (United States)

    US Agency for International Development — The MEASURE Evaluation Dataverse is a collection of innovative evaluation data sets assembled in order to increase the evidence-base on program impact and evaluate...

  16. Littoral Measurements Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Barny units measure ocean currents and sea surface heights on continental shelves and in ocean straits. SEPTR units are similar to Barnys but also record...

  17. Measurement of leached hulls

    International Nuclear Information System (INIS)

    Reilly, T.D.

    1979-07-01

    Leached hulls are the short lengths of fuel rod cladding and fuel element hardware which constitute a major waste product of a reprocessing plant employing a chop-and-leach head-end process. The small, undissolved fuel residue (0.1 to 1.0% of original fuel content) which is discarded with this waste must be measured for safeguards, material accountability, and process control reasons. This report gives a critical analysis of hull measurement techniques involving the analysis of fission product gamma rays, spontaneous fission neutrons from curium, and delayed neutron activation. Major emphasis is given to the measurement of 2186-keV gamma rays from 144 Ce-- 144 Pr. A detailed description of typical leached hull characteristics is presented at the beginning of the report. An extensive review of experience gained from existing hull measurement systems in the United Kingdom, France, Japan, Germany, Italy, and the United States is presented

  18. Statistical Measures of Marksmanship

    National Research Council Canada - National Science Library

    Johnson, Richard

    2001-01-01

    .... This report describes objective statistical procedures to measure both rifle marksmanship accuracy, the proximity of an array of shots to the center of mass of a target, and marksmanship precision...

  19. Pulse holographic measurement techniques

    International Nuclear Information System (INIS)

    Kim, Cheol Jung; Baik, Seong Hoon; Hong, Seok Kyung; Kim, Jeong Moog; Kim, Duk Hyun

    1992-01-01

    With the development of laser, remote inspection techniques using laser have been growing on. The inspection and measurement techniques by pulse holography are well-established technique for precise measurement, and widely used in various fields of industry now. In nuclear industry, this technology is practically used because holographic inspection is remote, noncontact, and precise measurement technique. In relation to remote inspection technology in nuclear industry, state-of-the art of pulse HNDT (Holographic non-destructive testing) and holographic measurement techniques are examined. First of all, the fundamental principles as well as practical problems for applications are briefly described. The fields of pulse holography have been divided into the HNDT, flow visualization and distribution study, and other application techniques. Additionally holographic particle study, bubble chamber holography, and applications to other visualization techniques are described. Lastly, the current status for the researches and applications of pulse holography to nuclear industry which are carried out actively in Europe and USA, is described. (Author)

  20. Measurement theory for engineers

    CERN Document Server

    Gertsbakh, Ilya

    2003-01-01

    The emphasis of this textbook is on industrial applications of Statistical Measurement Theory. It deals with the principal issues of measurement theory, is concise and intelligibly written, and to a wide extent self-contained. Difficult theoretical issues are separated from the mainstream presentation. Each topic starts with an informal introduction followed by an example, the rigorous problem formulation, solution method, and a detailed numerical solution. Each chapter concludes with a set of exercises of increasing difficulty, mostly with solutions. The book is meant as a text for graduate students and a reference for researchers and industrial experts specializing in measurement and measurement data analysis for quality control, quality engineering and industrial process improvement using statistical methods. Knowledge of calculus and fundamental probability and statistics is required for the understanding of its contents.

  1. Measuring Agricultural Bias

    DEFF Research Database (Denmark)

    Jensen, Henning Tarp; Robinson, Sherman; Tarp, Finn

    The measurement issue is the key issue in the literature on trade policy-induced agri-cultural price incentive bias. This paper introduces a general equilibrium effective rate of protection (GE-ERP) measure, which extends and generalizes earlier partial equilibrium nominal protection measures...... shares and intersectoral linkages - are crucial for determining the sign and magnitude of trade policy bias. The GE-ERP measure is therefore uniquely suited to capture the full impact of trade policies on agricultural price incentives. A Monte Carlo procedure confirms that the results are robust....... For the 15 sample countries, the results indicate that the agricultural price incentive bias, which was generally perceived to exist during the 1980s, was largely eliminated during the 1990s. The results also demonstrate that general equilibrium effects and country-specific characteristics - including trade...

  2. Environmental Measurements and Modeling

    Science.gov (United States)

    Environmental measurement is any data collection activity involving the assessment of chemical, physical, or biological factors in the environment which affect human health. Learn more about these programs and tools that aid in environmental decisions

  3. Polar measurements on profiles

    Energy Technology Data Exchange (ETDEWEB)

    Althaus, D.

    1985-03-01

    Wind tunnel models with a profile depth of t=0.5 m were measured in a laminar wind tunnel by the usual measuring processes. The profile resistance was determined by integration along the width of span. The smooth profiles were examined at Re=0.7/1.0 and 1.5 million. At Re=1.0 million, the position of the changeover points were determined with a stethoscope. Also at this Reynolds number measurements were taken with a trip wire of d=2 mm diameter, directly on the profile nose. The tables contain the co-ordinates of the profiles, the contours, the theoretical speed distributions for 4 different angles of attack, the csub(a)-csub(w) polar measurements and changeover points, and the torque coefficients around the t/4 point. (BR).

  4. Acceleration measurements in JEM

    International Nuclear Information System (INIS)

    Ikeda, Toshitami; Murakami, Keiji

    2000-01-01

    Since summer in 1996, National Space Development Agency of Japan (NASDA) has continued a concept study for a microgravity measurement apparatus (MMA) to be installed in the Japanese Experiment Module (JEM). The concept study was finished in 1998, and then we have been proceeding for a basic design. For experiments conducted with some of NASDA payloads in JEM-PM (Pressurized Module), measuring detailed microgravity environment was required. In addition, experiments to be performed with payload equipment attached on the JEM-EF (Exposed Facility) are requiring for obtaining the microgravity measurement data. Thus, we are adding some modification to the concept design of MMA in order to make the common hardware available for measurement of both environment in the JEM-PM and that of the JEM-EF. In this paper, the current development status of Japanese payloads and the modified concept of the MMA are introduced

  5. Essentials of measure theory

    CERN Document Server

    Kubrusly, Carlos S

    2015-01-01

    Classical in its approach, this textbook is thoughtfully designed and composed in two parts. Part I is meant for a one-semester beginning graduate course in measure theory, proposing an “abstract” approach to measure and integration, where the classical concrete cases of Lebesgue measure and Lebesgue integral are presented as an important particular case of general theory. Part II of the text is more advanced and is addressed to a more experienced reader. The material is designed to cover another one-semester graduate course subsequent to a first course, dealing with measure and integration in topological spaces. The final section of each chapter in Part I presents problems that are integral to each chapter, the majority of which consist of auxiliary results, extensions of the theory, examples, and counterexamples. Problems which are highly theoretical have accompanying hints. The last section of each chapter of Part II consists of Additional Propositions containing auxiliary and complementary results. Th...

  6. Control Measure Dataset

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA Control Measure Dataset is a collection of documents describing air pollution control available to regulated facilities for the control and abatement of air...

  7. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Local Programs Measuring Physical Activity Intensity Recommend on Facebook Tweet Share Compartir For more help with what ... RSS ABOUT About CDC Jobs Funding LEGAL Policies Privacy FOIA No Fear Act OIG 1600 Clifton Road ...

  8. Gas flowrate measurements

    International Nuclear Information System (INIS)

    Boure, Madeleine.

    1978-05-01

    The main types of gas flowmeters, especially those which are used for laboratory measurements are reviewed. Modeling, design recommendations, calibration methods and expected accuracy are discussed for each flowmeter. Different types and trademarks are given in two tables [fr

  9. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Compartir For more help with what counts as aerobic activity, watch this video: Windows Media Player, 4: ... ways to understand and measure the intensity of aerobic activity: relative intensity and absolute intensity. Relative Intensity ...

  10. Soliton microcomb range measurement

    Science.gov (United States)

    Suh, Myoung-Gyun; Vahala, Kerry J.

    2018-02-01

    Laser-based range measurement systems are important in many application areas, including autonomous vehicles, robotics, manufacturing, formation flying of satellites, and basic science. Coherent laser ranging systems using dual-frequency combs provide an unprecedented combination of long range, high precision, and fast update rate. We report dual-comb distance measurement using chip-based soliton microcombs. A single pump laser was used to generate dual-frequency combs within a single microresonator as counterpropagating solitons. We demonstrated time-of-flight measurement with 200-nanometer precision at an averaging time of 500 milliseconds within a range ambiguity of 16 millimeters. Measurements at distances up to 25 meters with much lower precision were also performed. Our chip-based source is an important step toward miniature dual-comb laser ranging systems that are suitable for photonic integration.

  11. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Physical Activity Basics Needs for Adults Needs for Children What Counts Needs for Older Adults Needs for ... Adding Physical Activity to Your Life Activities for Children Activities for Older Adults Overcoming Barriers Measuring Physical ...

  12. Measuring what's missing

    DEFF Research Database (Denmark)

    Jones, Edward Samuel

    2016-01-01

    mass. Using the UNDP's Human Development Index, the empirical performance of such coverage metrics are compared to alternative measures of convergence. The former are advantageous -- they provide probabilistic estimates of simulation coverage and permit calculation of strict bounds on estimates...

  13. Wearable 3D measurement

    Science.gov (United States)

    Manabe, Yoshitsugu; Imura, Masataka; Tsuchiya, Masanobu; Yasumuro, Yoshihiro; Chihara, Kunihiro

    2003-01-01

    Wearable 3D measurement realizes to acquire 3D information of an objects or an environment using a wearable computer. Recently, we can send voice and sound as well as pictures by mobile phone in Japan. Moreover it will become easy to capture and send data of short movie by it. On the other hand, the computers become compact and high performance. And it can easy connect to Internet by wireless LAN. Near future, we can use the wearable computer always and everywhere. So we will be able to send the three-dimensional data that is measured by wearable computer as a next new data. This paper proposes the measurement method and system of three-dimensional data of an object with the using of wearable computer. This method uses slit light projection for 3D measurement and user"s motion instead of scanning system.

  14. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Adults Need More Physical Activity MMWR Data Highlights State Indicator Report on Physical Activity, 2014 Recommendations & Guidelines ... Activity Overweight & Obesity Healthy Weight Breastfeeding Micronutrient Malnutrition State and Local Programs Measuring Physical Activity Intensity Recommend ...

  15. Measuring multifactor productivity growth

    Czech Academy of Sciences Publication Activity Database

    Wölfl, A.; Hájková, Dana

    -, 2007/5 (2007), s. 1-45 Institutional research plan: CEZ:AV0Z70850503 Keywords : multifactor productivity growth * GDP growth * measuring Subject RIV: AH - Economics http://www.oecd.org/dataoecd/61/17/39522985.pdf

  16. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... 10 miles per hour or faster Jumping rope Heavy gardening (continuous digging or hoeing) Hiking uphill or with a heavy backpack Other Methods of Measuring Intensity Target Heart ...

  17. Health System Measurement Project

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Health System Measurement Project tracks government data on critical U.S. health system indicators. The website presents national trend data as well as detailed...

  18. Uncertainty and measurement

    International Nuclear Information System (INIS)

    Landsberg, P.T.

    1990-01-01

    This paper explores how the quantum mechanics uncertainty relation can be considered to result from measurements. A distinction is drawn between the uncertainties obtained by scrutinising experiments and the standard deviation type of uncertainty definition used in quantum formalism. (UK)

  19. Improvement by GQM measurement

    NARCIS (Netherlands)

    Solingen, van D.M.; Veenendaal, van E.P.W.M.; Trienekens, J.; Veenendaal, van E.

    1997-01-01

    Software development is a discipline with specific management difficulties. Collecting relevant data during development is a way to overcome these difficulties. Such data collectionfor software development is termed ‘Software Measurement’. Software measurement is a poweiful aid to quality

  20. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Adults Needs for Children What Counts Needs for Older Adults Needs for Pregnant or Postpartum Women Physical Activity & ... to Your Life Activities for Children Activities for Older Adults Overcoming Barriers Measuring Physical Activity Intensity Target Heart ...

  1. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Hiking uphill or with a heavy backpack Other Methods of Measuring Intensity Target Heart Rate and Estimated ... Help: How do I view different file formats (PDF, DOC, PPT, MPEG) on this site? Adobe PDF ...

  2. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Hiking uphill or with a heavy backpack Other Methods of Measuring Intensity Target Heart Rate and Estimated ... YouTube Instagram Listen Watch RSS ABOUT About CDC Jobs Funding LEGAL Policies Privacy FOIA No Fear Act ...

  3. Performance Measurement at Universities

    DEFF Research Database (Denmark)

    Lueg, Klarissa

    2014-01-01

    This paper proposes empirical approaches to testing the reliability, validity, and organizational effectiveness of student evaluations of teaching (SET) as a performance measurement instrument in knowledge management at the institutional level of universities. Departing from Weber’s concept...

  4. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Measuring Intensity Target Heart Rate and Estimated Maximum Heart Rate Perceived Exertion (Borg Rating of Perceived Exertion Scale) Get Email Updates To receive email updates about this page, enter your email ... ...

  5. Dilepton measurements with CERES

    CERN Document Server

    Marin, A; Agakichiev, G; Andronic, A; Antonczyk, D; Appelshäuser, H; Bielcíkováe, V; Biel, J; Braun-Munzinger, P; Busch, O; Cherlin, A; Damjanovic, S; Dietel, T; Dietrich, L; Drees, A; Esumi, S I; Filimonov, K; Fomenko, K; Fraenkel, Zeev; Garabatos, C; Glässel, P; Hering, G; Holeczek, J; Kalisky, M; Kniege, S; Kushpil, V; Ludolphs, W; Maas, A; Milosevic, J; Miskowiec, D; Ortega, R; Panebratsev, Yu A; Petchenova, O; Petracek, V; Ploskon, M; Radomski, S; Rak, J; Ravinovich, I; Rehak, P; Sako, H; Schmitz, W; Schuchmann, S; Sedykh, S; Shimansky, S; Soualah, R; Stachel, J; Sumbera, M; Tilsner, H; Tserruya, Itzhak; Tsiledakis, G; Wessels, J P; Wienold, T; Wurm, J P; Yurevich, S; Yurevich, V

    2008-01-01

    We report on dilepton measurements for central Pb on Au collisions at the top CERN SPS energy with the upgraded CERES experiment. The dilepton mass spectrum of 2000 data with improved mass resolution shows an enhancement over the expectation from hadron decays that is well described by a model including a strong broadening of the $\\rho$ spectral function. The measured excess yield excludes the dropping mass scenario. We also report on the $\\phi$ meson measured simultaneously both in the $K^+K^-$ and in the dilepton decay channel for the first time in high energy heavy-ion collisions. An excellent agreement is found between the rapidity densities and the shape of the measured tranverse momentum spectrum. The data rule out a possible enhancement of the $\\phi$ yield in the leptonic over hadronic channel by a factor larger than 1.6 at 95% CL. CERES results are in agreement with NA49 results.

  6. Theory of Effectiveness Measurement

    National Research Council Canada - National Science Library

    Bullock, Richard K

    2006-01-01

    Effectiveness measures provide decision makers feedback on the impact of deliberate actions and affect critical issues such as allocation of scarce resources, as well as whether to maintain or change existing strategy...

  7. Photovoltaic spectral responsivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Emery, K.; Dunlavy, D.; Field, H.; Moriarty, T. [National Renewable Energy Lab., Golden, CO (United States)

    1998-09-01

    This paper discusses the various elemental random and nonrandom error sources in typical spectral responsivity measurement systems. The authors focus specifically on the filter and grating monochrometer-based spectral responsivity measurement systems used by the Photovoltaic (PV) performance characterization team at NREL. A variety of subtle measurement errors can occur that arise from a finite photo-current response time, bandwidth of the monochromatic light, waveform of the monochromatic light, and spatial uniformity of the monochromatic and bias lights; the errors depend on the light source, PV technology, and measurement system. The quantum efficiency can be a function of he voltage bias, light bias level, and, for some structures, the spectral content of the bias light or location on the PV device. This paper compares the advantages and problems associated with semiconductor-detector-based calibrations and pyroelectric-detector-based calibrations. Different current-to-voltage conversion and ac photo-current detection strategies employed at NREL are compared and contrasted.

  8. Nuclear measurements in industry

    International Nuclear Information System (INIS)

    Rozsa, S.

    1989-01-01

    In this book the author provides a description of nuclear measurements in industry, covering the physical principles, methods, instruments and equipment, and industrial applications. One of the great advantages of industrial nuclear measurements is that their use ensures the optimum use of raw material. The increasing cost of raw materials makes it essential to adhere strictly to the standards and prescriptions related to the product and this is possible only by the application of continuous and accurate measurements. As a result, the importance of nuclear instruments is rapidly growing particularly in fields where the application of alternative methods is not possible. This is illustrated by several practical examples described in the book. Similarly important are nuclear measuring the process control equipment which serve to optimize the use of energy in industrial processes

  9. Wake field measurements

    International Nuclear Information System (INIS)

    Palumbo, L.

    1989-01-01

    In this paper the concept of Wakefields and Machine Impedance are introduced. Several measurements technique of these quantities either in the laboratory before installation or from beam observation are presented

  10. Tomographic multiphase flow measurement

    International Nuclear Information System (INIS)

    Sætre, C.; Johansen, G.A.; Tjugum, S.A.

    2012-01-01

    Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain (). These are related to reducing measurement uncertainties arising from variations in the flow regime, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. This work focuses on the first two issues using multi gamma beam (MGB) measurements for identification of the type of flow regime. Further gamma ray tomographic measurements are used for reference of the gas/liquid distribution. For the MGB method one Am-241 source with principal emission at 59.5 keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second is positioned to the side so that this beam is close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the flow pattern, i.e. the instantaneous cross-sectional gas-liquid distribution. The measurement setup also includes Compton scattering measurements, which can provide information about the changes in the water salinity for flow segments with high water liquid ratio and low gas fractions. By measuring the transmitted intensity in short time slots (<100ms), rapid regime variations are revealed. From this we can select the time sections suitable for salinity measurements. Since the salinity variations change at the time scale of hours, a running average can be performed to increase the accuracy of the measurements. Recent results of this work will be presented here. - Highlights: ► Multiphase flow gas-fraction and flow regime measurements by multi gamma ray beams. ► High-speed gamma ray tomograph as reference for the flow pattern and gas fraction. ► Dual modality

  11. Tomographic multiphase flow measurement

    Energy Technology Data Exchange (ETDEWEB)

    Saetre, C., E-mail: camilla@ift.uib.no [Department of Physics and Technology, University of Bergen (Norway); Michelsen Centre for Industrial Measurement Science and Technology (Norway); Johansen, G.A. [Department of Physics and Technology, University of Bergen (Norway); Michelsen Centre for Industrial Measurement Science and Technology (Norway); Tjugum, S.A. [Michelsen Centre for Industrial Measurement Science and Technology (Norway); Roxar Flow Measurement, Bergen (Norway)

    2012-07-15

    Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain (). These are related to reducing measurement uncertainties arising from variations in the flow regime, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. This work focuses on the first two issues using multi gamma beam (MGB) measurements for identification of the type of flow regime. Further gamma ray tomographic measurements are used for reference of the gas/liquid distribution. For the MGB method one Am-241 source with principal emission at 59.5 keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second is positioned to the side so that this beam is close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the flow pattern, i.e. the instantaneous cross-sectional gas-liquid distribution. The measurement setup also includes Compton scattering measurements, which can provide information about the changes in the water salinity for flow segments with high water liquid ratio and low gas fractions. By measuring the transmitted intensity in short time slots (<100ms), rapid regime variations are revealed. From this we can select the time sections suitable for salinity measurements. Since the salinity variations change at the time scale of hours, a running average can be performed to increase the accuracy of the measurements. Recent results of this work will be presented here. - Highlights: Black-Right-Pointing-Pointer Multiphase flow gas-fraction and flow regime measurements by multi gamma ray beams. Black-Right-Pointing-Pointer High-speed gamma ray tomograph as reference for the flow

  12. Measuring Entrepreneurial Ecosystems

    OpenAIRE

    Stam, F.C.

    2017-01-01

    How can entrepreneurial ecosystems and productive entrepreneurship can be traced empirically and how is entrepreneurship related to entrepreneurial ecosystems. The analyses in this chapter show the value of taking a systems view on the context of entrepreneurship. We measure entrepreneurial ecosystem elements and use these to compose an entrepreneurial ecosystem index. Next, we measure the output of entrepreneurial ecosystems with different indicators of high-growth firms. We use the 12 provi...

  13. Safeguards and physics measurements

    Energy Technology Data Exchange (ETDEWEB)

    Carchon, R

    2002-04-01

    SCK-CEN's programme on safeguards and physics measurements involves gamma and neutron dosimetry, calibrations and irradiations, electronic support, metrology of various samples including internal contamination of human beings, of waste barrels and of fissile materials, neutron activation analysis, and radioisotope source preparation. The document reports on the main activities and achievements of the sections 'Instrumentation, Calibration and Dosimetry' and 'Safeguards and Nuclear Physics Measurements'.

  14. Lebesgue measure and gambling

    International Nuclear Information System (INIS)

    Kanovei, V G; Linton, Tom; Uspensky, Vladimir A

    2008-01-01

    Lebesgue measure of point sets is characterized in terms of the existence of various strategies in a certain coin-flipping game. 'Rational' and 'discrete' modifications of this game are investigated. We prove that if one of the players has a winning strategy in a game of this type depending on a given set P subset or equal [0,1], then this set is measurable. Bibliography: 11 titles.

  15. Lebesgue measure and gambling

    Science.gov (United States)

    Kanoveĭ, V. G.; Linton, Tom; Uspensky, Vladimir A.

    2008-12-01

    Lebesgue measure of point sets is characterized in terms of the existence of various strategies in a certain coin-flipping game. 'Rational' and 'discrete' modifications of this game are investigated. We prove that if one of the players has a winning strategy in a game of this type depending on a given set P\\subseteq \\lbrack 0,1 \\rbrack , then this set is measurable. Bibliography: 11 titles.

  16. Modulated Current Drive Measurements

    International Nuclear Information System (INIS)

    Petty, C.C.; Lohr, J.; Luce, T.C.; Prater, R.; Cox, W.A.; Forest, C.B.; Jayakumar, R.J.; Makowski, M.A.

    2005-01-01

    A new measurement approach is presented which directly determines the noninductive current profile from the periodic response of the motional Stark effect (MSE) signals to the slow modulation of the external current drive source. A Fourier transform of the poloidal magnetic flux diffusion equation is used to analyze the MSE data. An example of this measurement technique is shown using modulated electron cyclotron current drive (ECCD) discharges from the DIII-D tokamak

  17. Measurement of optical glasses

    International Nuclear Information System (INIS)

    Nicolau-Rebigan, S.

    1978-11-01

    The possibilities of measurement of the optical glasses parameters needed in building optical devices especially in lasers devices are presented. In the first chapter the general features of the main optical glasses as well as the modalities of obtaining them are given. Chapter two defines the optical glass parameters, and the third chapter describes the measuring methods of the optical glass parameters. Finally, the conclusions which point out the utilization of this paper are presented. (author)

  18. Measuring fluid pressure

    International Nuclear Information System (INIS)

    Lee, A.S.

    1978-01-01

    A method and apparatus are described for measuring the pressure of a fluid having characteristics that make it unsuitable for connection directly to a pressure gauge. The method is particularly suitable for the periodic measurement of the pressure of a supply of liquid Na to Na-lubricated bearings of pumps for pumping Na from a reservoir to the bearing via a filter, the reservoir being contained in a closed vessel containing an inert blanket gas, such as Ar, above the Na. (UK)

  19. Radiation dose measurements

    International Nuclear Information System (INIS)

    1960-01-01

    About 200 scientists from 28 countries and 5 international organizations met at a symposium on radiation dosimetry held by the International Atomic Energy Agency in June 1960. The aim of the symposium was not so much the description of a large number of measuring instruments as a discussion of the methods used, with special emphasis on those problems which had become important in the context of recent developments, such as the measurement of mixed or very large doses

  20. Temperature measurement and control

    CERN Document Server

    Leigh, JR

    1988-01-01

    This book treats the theory and practice of temperature measurement and control and important related topics such as energy management and air pollution. There are no specific prerequisites for the book although a knowledge of elementary control theory could be useful. The first half of the book is an application oriented survey of temperature measurement techniques and devices. The second half is concerned mainly with temperature control in both simple and complex situations.

  1. Safeguards and physics measurements

    International Nuclear Information System (INIS)

    Carchon, R.

    2002-01-01

    SCK-CEN's programme on safeguards and physics measurements involves gamma and neutron dosimetry, calibrations and irradiations, electronic support, metrology of various samples including internal contamination of human beings, of waste barrels and of fissile materials, neutron activation analysis, and radioisotope source preparation. The document reports on the main activities and achievements of the sections 'Instrumentation, Calibration and Dosimetry' and 'Safeguards and Nuclear Physics Measurements'

  2. 4. Measuring technique

    International Nuclear Information System (INIS)

    2006-01-01

    It is noted that in nuclear medicine a most widely the scintillation detectors are applying. Action of these detectors is based on registration of light flares in visible and ultraviolet field arising in scintillator under ionizing radiation action. In the chapter following subchapters are included: gamma-spectrometer and gamma radiation detectors; counter of whole body; measuring of accumulated activity (uptake measurements); scanner; scintillation chamber; single-photon emission computed tomography; positron emission computed tomography; magnet resonance tomography; computer technique, images making

  3. Soil conservation measures: exercises

    OpenAIRE

    Figueiredo, Tomás de; Fonseca, Felícia

    2009-01-01

    Exercises proposed under the topic of Soil Conservation Measures addresses to the design of structural measure, namely waterways in the context of a soil conservation plan. However, to get a better insight on the actual meaning of soil loss as a resource loss, a prior exercise is proposed to students. It concerns calculations of soil loss due to sheet (interrill) erosion and to gully erosion, and allows the perception through realistic number of the impact of these mechanism...

  4. Thermal power measurement apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Thermal power measurements are important in nuclear power plants, fossil-fuel plants and other closed loop systems such as heat exchangers and chemical reactors. The main object of this invention is to determine the enthalpy of a fluid using only acoustically determined sound speed and correlating the speed with enthalpy. An enthalpy change is measured between two points in the fluid flow: the apparatus is described in detail. (U.K.)

  5. Pressure Measurement Systems

    Science.gov (United States)

    1990-01-01

    System 8400 is an advanced system for measurement of gas and liquid pressure, along with a variety of other parameters, including voltage, frequency and digital inputs. System 8400 offers exceptionally high speed data acquisition through parallel processing, and its modular design allows expansion from a relatively inexpensive entry level system by the addition of modular Input Units that can be installed or removed in minutes. Douglas Juanarena was on the team of engineers that developed a new technology known as ESP (electronically scanned pressure). The Langley ESP measurement system was based on miniature integrated circuit pressure-sensing transducers that communicated pressure information to a minicomputer. In 1977, Juanarena formed PSI to exploit the NASA technology. In 1978 he left Langley, obtained a NASA license for the technology, introduced the first commercial product, the 780B pressure measurement system. PSI developed a pressure scanner for automation of industrial processes. Now in its second design generation, the DPT-6400 is capable of making 2,000 measurements a second and has 64 channels by addition of slave units. New system 8400 represents PSI's bid to further exploit the 600 million U.S. industrial pressure measurement market. It is geared to provide a turnkey solution to physical measurement.

  6. Precision lifetime measurements

    International Nuclear Information System (INIS)

    Tanner, C.E.

    1994-01-01

    Precision measurements of atomic lifetimes provide important information necessary for testing atomic theory. The authors employ resonant laser excitation of a fast atomic beam to measure excited state lifetimes by observing the decay-in-flight of the emitted fluorescence. A similar technique was used by Gaupp, et al., who reported measurements with precisions of less than 0.2%. Their program includes lifetime measurements of the low lying p states in alkali and alkali like systems. Motivation for this work comes from a need to test the atomic many-body-perturbation theory (MBPT) that is necessary for interpretation of parity nonconservation experiments in atomic cesium. The authors have measured the cesium 6p 2 P 1/2 and 6p 2 P 3/2 state lifetimes to be 34.934±0.094 ns and 30.499±0.070 ns respectively. With minor changes to the apparatus, they have extended their measurements to include the lithium 2p 2 P 1/2 and 2p 2 P 3/2 states

  7. Measurement quality assurance

    International Nuclear Information System (INIS)

    Eisenhower, E.H.

    1988-01-01

    The quality of a radiation protection program can be no better than the quality of the measurements made to support it. In many cases, that quality is unknown and is merely implied on the basis of a calibration of a measuring instrument. If that calibration is inappropriate or is performed improperly, the measurement result will be inaccurate and misleading. Assurance of measurement quality can be achieved if appropriate procedures are followed, including periodic quality control actions that demonstrate adequate performance. Several national measurement quality assurance (MQA) programs are operational or under development in specific areas. They employ secondary standards laboratories that provide a high-quality link between the National Bureau of Standards and measurements made at the field use level. The procedures followed by these secondary laboratories to achieve MQA will be described, as well as plans for similar future programs. A growing general national interest in quality assurance, combined with strong specific motivations for MQA in the area of ionizing radiation, will provide continued demand for appropriate national programs. Such programs must, however, employ procedures that are cost effective and must be developed with participation by all affected parties

  8. Critique of protective measurements

    International Nuclear Information System (INIS)

    Hari Dass, N.D.; Qureshi, T.

    1999-01-01

    The recently proposed idea of open-quotes protectiveclose quotes measurement of a quantum state is critically examined, and generalized. Earlier criticisms of the idea are discussed, and their relevance to the proposal assessed. Several constraints on measuring apparatus required by open-quotes protectiveclose quotes measurements are discussed, with emphasis on how they may restrict their experimental feasibility. Though open-quotes protectiveclose quotes measurements result in an unchanged system state and a shift of the pointer proportional to the expectation value of the measured observable in the system state, the actual reading of the pointer position gives rise to several subtleties. We propose several schemes for reading the pointer position, both when the apparatus is treated as a classical system as well as when its quantum aspects are taken into account, that address these issues. The tiny entanglement which is always present due to deviation from extreme adiabaticity in realistic situations is argued to be the weakest aspect of the proposal. Because of this, one can never perform a protective measurement on a single quantum system with absolute certainty. This clearly precludes an ontological status for the wave function. Several other conceptual issues are also discussed. copyright 1999 The American Physical Society

  9. Measure problem in cosmology

    International Nuclear Information System (INIS)

    Gibbons, G. W.; Turok, Neil

    2008-01-01

    The Hamiltonian structure of general relativity provides a natural canonical measure on the space of all classical universes, i.e., the multiverse. We review this construction and show how one can visualize the measure in terms of a 'magnetic flux' of solutions through phase space. Previous studies identified a divergence in the measure, which we observe to be due to the dilatation invariance of flat Friedmann-Lemaitre-Robertson-Walker universes. We show that the divergence is removed if we identify universes which are so flat they cannot be observationally distinguished. The resulting measure is independent of time and of the choice of coordinates on the space of fields. We further show that, for some quantities of interest, the measure is very insensitive to the details of how the identification is made. One such quantity is the probability of inflation in simple scalar field models. We find that, according to our implementation of the canonical measure, the probability for N e-folds of inflation in single-field, slow-roll models is suppressed by of order exp(-3N) and we discuss the implications of this result.

  10. Radiation ray measuring device

    International Nuclear Information System (INIS)

    Maekawa, Tatsuyuki; Ida, Masaki.

    1997-01-01

    The present invention provides a chained-radiation ray monitoring system which can be applied to an actual monitoring system of a nuclear power plant or the like. Namely, this device comprises a plurality of scintillation detectors. Each of the detectors has two light take-out ports for emitting light corresponding to radiation rays irradiated from the object of the measurement to optical fibers. In addition, incident light from the optical fiber by way of one of the light take-out optical ports is transmitted to the other of the ports and sent from the other optical port to the fibers. Plurality sets of measuring systems are provided in which each of the detectors are disposed corresponding to a plurality of objects to be measured. A signal processing device is (1) connected with optical fibers of plurality sets of measuring systems in conjunction, (2) detects the optical pulses inputted from the optical fibers to identify the detector from which the optical pulses are sent and (3) measures the amount of radiation rays detected by the identified detector. As a result, the device of the present invention can form a measuring system with redundancy. (I.S.)

  11. Lead Thickness Measurements

    International Nuclear Information System (INIS)

    Rucinski, R.

    1998-01-01

    The preshower lead thickness applied to the outside of D-Zero's superconducting solenoid vacuum shell was measured at the time of application. This engineering documents those thickness measurements. The lead was ordered in sheets 0.09375-inch and 0.0625-inch thick. The tolerance on thickness was specified to be +/- 0.003-inch. The sheets all were within that thickness tolerance. The nomenclature for each sheet was designated 1T, 1B, 2T, 2B where the numeral designates it's location in the wrap and 'T' or 'B' is short for 'top' or 'bottom' half of the solenoid. Micrometer measurements were taken at six locations around the perimeter of each sheet. The width,length, and weight of each piece was then measured. Using an assumed pure lead density of 0.40974 lb/in 3 , an average sheet thickness was calculated and compared to the perimeter thickness measurements. In every case, the calculated average thickness was a few mils thinner than the perimeter measurements. The ratio was constant, 0.98. This discrepancy is likely due to the assumed pure lead density. It is not felt that the perimeter is thicker than the center regions. The data suggests that the physical thickness of the sheets is uniform to +/- 0.0015-inch.

  12. Measurement of short bunches

    International Nuclear Information System (INIS)

    Wang, D.X.

    1996-01-01

    In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson Lab are presented. At Jefferson Lab, bunch lengths as short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented. (author)

  13. Measurement of short bunches

    International Nuclear Information System (INIS)

    Wang, D.X.

    1996-01-01

    In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson lab are presented. At Jefferson Lab, bunch lengths s short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented

  14. Thermal Testing Measurements Report

    Energy Technology Data Exchange (ETDEWEB)

    R. Wagner

    2002-09-26

    The purpose of the Thermal Testing Measurements Report (Scientific Analysis Report) is to document, in one report, the comprehensive set of measurements taken within the Yucca Mountain Project Thermal Testing Program since its inception in 1996. Currently, the testing performed and measurements collected are either scattered in many level 3 and level 4 milestone reports or, in the case of the ongoing Drift Scale Test, mostly documented in eight informal progress reports. Documentation in existing reports is uneven in level of detail and quality. Furthermore, while all the data collected within the Yucca Mountain Site Characterization Project (YMP) Thermal Testing Program have been submitted periodically to the Technical Data Management System (TDMS), the data structure--several incremental submittals, and documentation formats--are such that the data are often not user-friendly except to those who acquired and processed the data. The documentation in this report is intended to make data collected within the YMP Thermal Testing Program readily usable to end users, such as those representing the Performance Assessment Project, Repository Design Project, and Engineered Systems Sub-Project. Since either detailed level 3 and level 4 reports exist or the measurements are straightforward, only brief discussions are provided for each data set. These brief discussions for different data sets are intended to impart a clear sense of applicability of data, so that they will be used properly within the context of measurement uncertainty. This approach also keeps this report to a manageable size, an important consideration because the report encompasses nearly all measurements for three long-term thermal tests. As appropriate, thermal testing data currently residing in the TDMS have been reorganized and reformatted from cumbersome, user-unfriendly Input-Data Tracking Numbers (DTNs) into a new set of Output-DTNs. These Output-DTNs provide a readily usable data structure

  15. Optical fuel spray measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hillamo, H.

    2011-07-01

    Diesel fuel sprays, including fuel/air mixing and the physics of two-phase jet formation, are discussed in the thesis. The fuel/air mixing strongly affects emissions formation in spray combustion processes where the local combustion conditions dictate the emission formation. This study comprises optical measurements both in pressurized spray test rigs and in a running engine.The studied fuel injection was arranged with a common rail injection system and the injectors were operated with a solenoid-based injection valve. Both marine and heavy-duty diesel engine injectors were used in the study. Optical fuel spray measurements were carried out with a laser-based double-framing camera system. This kind of equipments is usually used for flow field measurements with Particle Image Velocimetry technique (PIV) as well as for backlight imaging. Fundamental fuel spray properties and spray formation were studied in spray test rigs. These measurements involved studies of mixing, atomization, and the flow field. Test rig measurements were used to study the effect of individual injection parameters and component designs. Measurements of the fuel spray flow field, spray penetration, spray tip velocity, spray angle, spray structure, droplet accumulation, and droplet size estimates are shown. Measurement campaign in a running optically accessible large-bore medium-speed engine was also carried out. The results from engine tests were compared with equivalent test rig measurements, as well as computational results, to evaluate the level of understanding of sprays. It was shown that transient spray has an acceleration and a deceleration phase. Successive flow field measurements (PIV) in optically dense diesel spray resulted in local and average velocity data of diesel sprays. Processing fuel spray generates a flow field to surrounding gas and entrainment of surrounding gas into fuel jet was also seen at the sides of the spray. Laser sheet imaging revealed the inner structure of diesel

  16. Grid-Enabled Measures

    Science.gov (United States)

    Moser, Richard P.; Hesse, Bradford W.; Shaikh, Abdul R.; Courtney, Paul; Morgan, Glen; Augustson, Erik; Kobrin, Sarah; Levin, Kerry; Helba, Cynthia; Garner, David; Dunn, Marsha; Coa, Kisha

    2011-01-01

    Scientists are taking advantage of the Internet and collaborative web technology to accelerate discovery in a massively connected, participative environment —a phenomenon referred to by some as Science 2.0. As a new way of doing science, this phenomenon has the potential to push science forward in a more efficient manner than was previously possible. The Grid-Enabled Measures (GEM) database has been conceptualized as an instantiation of Science 2.0 principles by the National Cancer Institute with two overarching goals: (1) Promote the use of standardized measures, which are tied to theoretically based constructs; and (2) Facilitate the ability to share harmonized data resulting from the use of standardized measures. This is done by creating an online venue connected to the Cancer Biomedical Informatics Grid (caBIG®) where a virtual community of researchers can collaborate together and come to consensus on measures by rating, commenting and viewing meta-data about the measures and associated constructs. This paper will describe the web 2.0 principles on which the GEM database is based, describe its functionality, and discuss some of the important issues involved with creating the GEM database, such as the role of mutually agreed-on ontologies (i.e., knowledge categories and the relationships among these categories— for data sharing). PMID:21521586

  17. Measurements of fireball onset

    Science.gov (United States)

    Scheiner, Brett; Barnat, Edward V.; Baalrud, Scott D.; Hopkins, Matthew M.; Yee, Benjamin T.

    2018-04-01

    Laser-based measurements of the characteristic features of fireball onset and stabilization in response to a stepped voltage applied to an anode immersed in a low pressure (100 mTorr) helium afterglow are reported. These include spatial and temporal evolution of metastable species, electron density, and electric field magnitude as measured by planar laser induced fluorescence, laser-collision induced fluorescence, and laser-induced fluorescence-dip spectroscopy, respectively. These measurements are found to be in qualitative agreement with recent particle-in-cell simulations and theoretical models [Scheiner et al., Phys. Plasmas 24, 113520 (2017)]. The measurements validate the simulations and models in which fireball onset was predicted to follow from the trapping of electrons born from electron impact ionization within a potential well created by a buildup of ions in the sheath. The experimental measurements also demonstrate transient features following the onset that were not present in previous simulations. New simulation results are presented which demonstrate that these features are associated with the abruptness of the voltage step used to initiate fireball onset. An abrupt step in the anode bias causes rapid displacement of ions and an associated plasma potential response following the sheath and fireball expansion.

  18. Neutron fluence measurements

    International Nuclear Information System (INIS)

    1970-01-01

    For research reactor work dealing with such subjects as radiation effects on solids and such disciplines as radiochemistry and radiobiology, the radiation dose or neutron fluence is an essential parameter in evaluating results. Unfortunately it is very difficult to determine. Even when the measurements have been accurate, it is difficult to compare results obtained in different experiments because present methods do not always reflect the dependence of spectra or of different types of radiation on the induced processes. After considering the recommendations of three IAEA Panels, on 'In-pile dosimetry' held in July 1964, on 'Neutron fluence measurements' in October 1965, and on 'In-pile dosimetry' in November 1966, the Agency established a Working Group on Reactor Radiation Measurements. This group consisted of eleven experts from ten different Member States and two staff members of the Agency. In the measurement of energy absorbed by materials from neutrons and gamma rays, there are various reports and reviews scattered throughout the literature. The group, however, considered that the time was ripe for all relevant information to be evaluated and gathered together in the form of a practical guide, with the aim of promoting consistency in the measurement and reporting of reactor radiation. The group arranged for the material to be divided into two manuals, which are expected to be useful both for experienced workers and for beginners

  19. Inmate punishments: Disciplinary measures

    Directory of Open Access Journals (Sweden)

    Milić Ivan D.

    2016-01-01

    Full Text Available After the verdict has become formal and enforceable, and the defendant a convict, sentence execution procedure follows. If the defendant is sentenced to prison, the next step to be taken is the referral institution for execution of sentence of imprisonment. Rules of conduct in the institutions for execution of imprisonment are strictly regulated by legislation governing the rights and obligations of prisoners. Conducts that are prohibited in institutions shall be prescribed as a disciplinary offense, and appropriate disciplinary measures are to be imposed. The subject of this paper are disciplinary measures stipulated by the Law on Execution of Criminal Sanctions of the Republic of Serbia. The paper gives an overview of five disciplinary measures that can be imposed for serious or minor disciplinary offenses. In particular, author focuses his attention to indicating that the imposition and execution of disciplinary measures, are not regulated by Law in the best possible way, so that, in practice, certain problems arise in the application of these measures.

  20. Measuring past a micron...

    CERN Multimedia

    Anaïs Schaeffer

    2011-01-01

    Infinity: That is the name of the new ultra-precision machine used by CERN's Metrology Service to measure the copper components for the CLIC accelerating structures. This project is the result of a collaboration between CLIC and the EN Department. Curious to find out more? Read on because there’ll be an opportunity for you to get a very close look at Infinity!    Infinity, the new, ultra-precise, measuring machine, is currently in operation at the CERN Metrology Service. The CLIC (Compact LInear Collider) radiofrequency structures will operate under very high electric fields (100 MV/m). They should be manufactured within minimal mechanical tolerances. To validate the quality of these components, they have to be measured with a precision that far exceeds the machining tolerances, i.e. 0.3 microns. No “ordinary” measuring machine can achieve this precision, but Infinity, the newly developed high-precision three-dimensional measuring machine i...

  1. The performance measurement manifesto.

    Science.gov (United States)

    Eccles, R G

    1991-01-01

    The leading indicators of business performance cannot be found in financial data alone. Quality, customer satisfaction, innovation, market share--metrics like these often reflect a company's economic condition and growth prospects better than its reported earnings do. Depending on an accounting department to reveal a company's future will leave it hopelessly mired in the past. More and more managers are changing their company's performance measurement systems to track nonfinancial measures and reinforce new competitive strategies. Five activities are essential: developing an information architecture; putting the technology in place to support this architecture; aligning bonuses and other incentives with the new system; drawing on outside resources; and designing an internal process to ensure the other four activities occur. New technologies and more sophisticated databases have made the change to nonfinancial performance measurement systems possible and economically feasible. Industry and trade associations, consulting firms, and public accounting firms that already have well-developed methods for assessing market share and other performance metrics can add to the revolution's momentum--as well as profit from the business opportunities it presents. Every company will have its own key measures and distinctive process for implementing the change. But making it happen will always require careful preparation, perseverance, and the conviction of the CEO that it must be carried through. When one leading company can demonstrate the long-term advantage of its superior performance on quality or innovation or any other nonfinancial measure, it will change the rules for all its rivals forever.

  2. Thermal Properties Measurement Report

    Energy Technology Data Exchange (ETDEWEB)

    Carmack, Jon [Idaho National Lab. (INL), Idaho Falls, ID (United States); Braase, Lori [Idaho National Lab. (INL), Idaho Falls, ID (United States); Papesch, Cynthia [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hurley, David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Tonks, Michael [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Yongfeng [Idaho National Lab. (INL), Idaho Falls, ID (United States); Gofryk, Krzysztof [Idaho National Lab. (INL), Idaho Falls, ID (United States); Harp, Jason [Idaho National Lab. (INL), Idaho Falls, ID (United States); Fielding, Randy [Idaho National Lab. (INL), Idaho Falls, ID (United States); Knight, Collin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Meyer, Mitch [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-08-01

    The Thermal Properties Measurement Report summarizes the research, development, installation, and initial use of significant experimental thermal property characterization capabilities at the INL in FY 2015. These new capabilities were used to characterize a U3Si2 (candidate Accident Tolerant) fuel sample fabricated at the INL. The ability to perform measurements at various length scales is important and provides additional data that is not currently in the literature. However, the real value of the data will be in accomplishing a phenomenological understanding of the thermal conductivity in fuels and the ties to predictive modeling. Thus, the MARMOT advanced modeling and simulation capability was utilized to illustrate how the microstructural data can be modeled and compared with bulk characterization data. A scientific method was established for thermal property measurement capability on irradiated nuclear fuel samples, which will be installed in the Irradiated Material Characterization Laboratory (IMCL).

  3. Challenge Measurements For Authentication

    International Nuclear Information System (INIS)

    Pitts, W. Karl

    2009-01-01

    Authentication of systems with an information barrier that protects sensitive information is difficult; in particular, the information barrier can allow a hidden switch to be implemented by the system fabricator and operator. The hidden switch is the operator's ability to subvert the measurement system and force it to produce a desired and false result. It is usually discussed in the context of an attribute measurement in which a faked item is presented in place of a real item regulated by an agreement, with the driving motivation being the ability to preserve a stock of valuable items. In simple terms, the hidden switch enables a shell game with assets, and the information barrier protects the switch. This presentation outlines challenge measurements that could be used to detect the implementation of a hidden switch and assist the authentication process.

  4. Electrochemical thermodynamic measurement system

    Science.gov (United States)

    Reynier, Yvan [Meylan, FR; Yazami, Rachid [Los Angeles, CA; Fultz, Brent T [Pasadena, CA

    2009-09-29

    The present invention provides systems and methods for accurately characterizing thermodynamic and materials properties of electrodes and electrochemical energy storage and conversion systems. Systems and methods of the present invention are configured for simultaneously collecting a suite of measurements characterizing a plurality of interconnected electrochemical and thermodynamic parameters relating to the electrode reaction state of advancement, voltage and temperature. Enhanced sensitivity provided by the present methods and systems combined with measurement conditions that reflect thermodynamically stabilized electrode conditions allow very accurate measurement of thermodynamic parameters, including state functions such as the Gibbs free energy, enthalpy and entropy of electrode/electrochemical cell reactions, that enable prediction of important performance attributes of electrode materials and electrochemical systems, such as the energy, power density, current rate and the cycle life of an electrochemical cell.

  5. Temperature measurement device

    International Nuclear Information System (INIS)

    Fournier, Christian; Lions, Noel.

    1975-01-01

    The present invention relates to a temperature measuring system that can be applied in particular to monitoring the temperature of the cooling liquid metal of the outlet of the core assemblies of a fast reactor. Said device combines a long hollow metallic pole, at least partially dipped into the liquid metal and constituting a first thermocouple junction between said pole, and two metallic conductors of different nature, joined at one of their ends to constitute the second thermocouple junction. Said conductors suitably insulated are arranged inside a sheath. Said sheath made of the same metals as the pole extends inside the latter and is connected with the pole through a soldered joint. Said reliable system permits an instantaneous measurement of a quantity representing the variations in the recorded temperature and a measurement of the mean surrounding temperature that can be direcly used as a reference for calibrating the first one [fr

  6. Measuring Social Capital

    DEFF Research Database (Denmark)

    Svendsen, Gert Tinggaard; Bjørnskov, Christian

    2007-01-01

    How to construct a robust measure of social capital? This paper contains two contributions. The first is an attempt to establish a broad social capital measure based on four indicators, the Freedom House Index, an index of perceived corruption from Transparency International, and scores on civic...... participation and generalized trust. This measure is then applied by comparing the level of social capital in 25 countries from Western and Eastern Europe. Our nine cluster analysis shows that Switzerland has the highest score, followed by the Netherlands and Scandinavia. At the other end of the continuum we...... find post-communist countries and Southern Italy. The findings for this specific sample suggest that institutions matter for social capital and the relationship between decentralization and social capital emerges as a promising line of inquiry. Thus, the highest scoring countries in the sample may...

  7. Neutron beam measurement dosimetry

    International Nuclear Information System (INIS)

    Amaro, C.R.

    1995-01-01

    This report describes animal dosimetry studies and phantom measurements. During 1994, 12 dogs were irradiated at BMRR as part of a 4 fraction dose tolerance study. The animals were first infused with BSH and irradiated daily for 4 consecutive days. BNL irradiated 2 beagles as part of their dose tolerance study using BPA fructose. In addition, a dog at WSU was irradiated at BMRR after an infusion of BPA fructose. During 1994, the INEL BNCT dosimetry team measured neutron flux and gamma dose profiles in two phantoms exposed to the epithermal neutron beam at the BMRR. These measurements were performed as a preparatory step to the commencement of human clinical trials in progress at the BMRR

  8. Enterprise performance measurement systems

    Directory of Open Access Journals (Sweden)

    Milija Bogavac

    2014-10-01

    Full Text Available Performance measurement systems are an extremely important part of the control and management actions, because in this way a company can determine its business potential, its market power, potential and current level of business efficiency. The significance of measurement consists in influencing the relationship between the results of reproduction (total volume of production, value of production, total revenue and profit and investments to achieve these results (factors of production spending and hiring capital in order to achieve the highest possible quality of the economy. (The relationship between the results of reproduction and investment to achieve them quantitatively determines economic success as the quality of the economy. Measuring performance allows the identification of the economic resources the company has, so looking at the key factors that affect its performance can help to determine the appropriate course of action.

  9. Enhanced Microfluidic Electromagnetic Measurements

    Science.gov (United States)

    Giovangrandi, Laurent (Inventor); Ricco, Antonio J. (Inventor); Kovacs, Gregory (Inventor)

    2015-01-01

    Techniques for enhanced microfluidic impedance spectroscopy include causing a core fluid to flow into a channel between two sheath flows of one or more sheath fluids different from the core fluid. Flow in the channel is laminar. A dielectric constant of a fluid constituting either sheath flow is much less than a dielectric constant of the core fluid. Electrical impedance is measured in the channel between at least a first pair of electrodes. In some embodiments, enhanced optical measurements include causing a core fluid to flow into a channel between two sheath flows of one or more sheath fluids different from the core fluid. An optical index of refraction of a fluid constituting either sheath flow is much less than an optical index of refraction of the core fluid. An optical property is measured in the channel.

  10. Structural power flow measurement

    Energy Technology Data Exchange (ETDEWEB)

    Falter, K.J.; Keltie, R.F.

    1988-12-01

    Previous investigations of structural power flow through beam-like structures resulted in some unexplained anomalies in the calculated data. In order to develop structural power flow measurement as a viable technique for machine tool design, the causes of these anomalies needed to be found. Once found, techniques for eliminating the errors could be developed. Error sources were found in the experimental apparatus itself as well as in the instrumentation. Although flexural waves are the carriers of power in the experimental apparatus, at some frequencies longitudinal waves were excited which were picked up by the accelerometers and altered power measurements. Errors were found in the phase and gain response of the sensors and amplifiers used for measurement. A transfer function correction technique was employed to compensate for these instrumentation errors.

  11. Production measurements at LHCb

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00392425

    2017-01-01

    The $\\text{LHC}b$ detector, with its excellent momentum resolution and flexible trigger strategy, is ideally suited for measuring heavy quark and quarkonia production properties. In addition, the new system of forward shower counters installed upstream and downstream has begun to be used, therefore the experiment is being suited to measure central exclusive production. The $\\text{LHC}b$ measurements of inclusive and differential cross-sections of the production of $J/\\psi$ resonance and $J/\\psi$ pairs, as well bottom quarks and $Z^0$ boson, based on Run 2 datasets are summarized. Finally, results on the prompt production of open charm hadrons and the exclusive production of charmonium are discussed.

  12. Traceability and Measurement Uncertainty

    DEFF Research Database (Denmark)

    Tosello, Guido; De Chiffre, Leonardo

    2004-01-01

    . The project partnership aims (composed by 7 partners in 5 countries, thus covering a real European spread in high tech production technology) to develop and implement an advanced e-learning system that integrates contributions from quite different disciplines into a user-centred approach that strictly....... Machine tool testing 9. The role of manufacturing metrology for QM 10. Inspection planning 11. Quality management of measurements incl. Documentation 12. Advanced manufacturing measurement technology The present report (which represents the section 2 - Traceability and Measurement Uncertainty – of the e-learning......This report is made as a part of the project ‘Metro-E-Learn: European e-Learning in Manufacturing Metrology’, an EU project under the program SOCRATES MINERVA (ODL and ICT in Education), Contract No: 101434-CP-1-2002-1-DE-MINERVA, coordinated by Friedrich-Alexander-University Erlangen...

  13. Post Fukushima measures

    International Nuclear Information System (INIS)

    Mehra, V.K.

    2014-01-01

    'Stress test' of all nuclear power plants initiated in European Union examines robustness of the plant against extreme natural events coupled with loss of all electric power supplies and ultimate heat sink and ineffective counter measures. 'Complementary Safety Measures' suggested by the French Regulatory Authority have enhanced scope of the assessment of resistance to extreme natural events to all nuclear facilities. A truncated system of equipment and systems hardened against extreme events would evolve from such an exercise so that possibility of radioactive release and evacuation of people does not rise again. Computer simulation of the accident at Fukushima Dai-ichi plant was initiated almost simultaneously with the accident. Apart from bench marking the analysis programs, such an exercise will help in quantitative implementation of counter measures and identification of research areas. Additional regulatory requirements are being proposed to prevent core damage or containment failure and to suppress dispersal of radioactive materials

  14. Measuring efficiency in logistics

    Directory of Open Access Journals (Sweden)

    Milan Milovan Andrejić

    2013-06-01

    Full Text Available Dynamic market and environmental changes greatly affect operating of logistics systems. Logistics systems have to realize their activities and processes in an efficient way. The main objective of this paper is to analyze different aspects of efficiency measurement in logistics and to propose appropriate models of measurement. Measuring efficiency in logistics is a complex process that requires consideration of all subsystems, processes and activities as well as the impact of various financial, operational, environmental, quality and other factors. The proposed models have a basis in the Data Envelopment Analysis method. They could help managers in decision making and corrective actions processes. The tests and results of the model show the importance of input and output variables selection.

  15. Measurement of complex surfaces

    International Nuclear Information System (INIS)

    Brown, G.M.

    1993-05-01

    Several of the components used in coil fabrication involve complex surfaces and dimensions that are not well suited to measurements using conventional dimensional measuring equipment. Some relatively simple techniques that are in use in the SSCL Magnet Systems Division (MSD) for incoming inspection will be described, with discussion of their suitability for specific applications. Components that are submitted for MSD Quality Assurance (QA) dimensional inspection may be divided into two distinct categories; the first category involves components for which there is an approved drawing and for which all nominal dimensions are known; the second category involves parts for which 'reverse engineering' is required, the part is available but there are no available drawings or dimensions. This second category typically occurs during development of coil end parts and coil turn filler parts where it is necessary to manually shape the part and then measure it to develop the information required to prepare a drawing for the part

  16. Measuring ambivalence to science

    Science.gov (United States)

    Gardner, P. L.

    Ambivalence is a psychological state in which a person holds mixed feelings (positive and negative) towards some psychological object. Standard methods of attitude measurement, such as Likert and semantic differential scales, ignore the possibility of ambivalence; ambivalent responses cannot be distinguished from neutral ones. This neglect arises out of an assumption that positive and negative affects towards a particular psychological object are bipolar, i.e., unidimensional in opposite directions. This assumption is frequently untenable. Conventional item statistics and measures of test internal consistency are ineffective as checks on this assumption; it is possible for a scale to be multidimensional and still display apparent internal consistency. Factor analysis is a more effective procedure. Methods of measuring ambivalence are suggested, and implications for research are discussed.

  17. The measurement of sparkle

    Science.gov (United States)

    Ferrero, A.; Bayón, S.

    2015-04-01

    Sparkle is a non-uniform texture effect consisting of very bright spots distributed on a dark surround. To date the only commercially-available instrument able to quantify sparkle is BYK-mac. This instrument allows sparkle parameters to be obtained, which should correlate with the visual experience. However, the measurands corresponding to these parameters are not clearly defined and they cannot be measured by any other instruments. In this article, we describe a procedure to measure quantities of well-defined sparkle measurands. We present experimental results at a combination of well-distributed illumination/viewing geometries within the incident plane. From this study, four descriptors are derived which may be correlated with visual attributes of sparkle. Finally, the procedure to estimate the perceived sparkle at any given surround luminance from the measured sparkle quantities is explained.

  18. B meson lifetime measurement

    International Nuclear Information System (INIS)

    Piccolo, M.

    1989-01-01

    The lifetime of hadrons containing b-quark has been the subject of extensive experimental work and theoretical speculation; its importance is due to implications on some of the fundamental parameters of the Standard Model, such as the top quark mass and the mixing angles. Since the pioneer measurements of the MAC and MARK II collaborations at PEP in 1983 the progress has been impressive; but many issues still remain open and await further study. In this paper the field's present status is discussed. An overview of the theoretical motivations for this measurements in the Standard Model framework is done. Then the experimental techniques used are reviewed, emphasizing the most recent measurements. A comparison of the results obtained is done and systematic errors are discussed. In conclusion there are some remarks on the further developments foreseen in the near future

  19. Measuring marketing effectiveness.

    Science.gov (United States)

    Gluckman, J; Michaelis, T

    1987-09-01

    The most frequent question about the marketing function in hospitals today is, What are we getting for our money? To answer this, marketing directors must convince the board first of the need for marketing, then of marketing's effectiveness. To measure marketing effectiveness, some basic needs are a staff, equipment, cooperation between departments, utilization data, and a research budget. Some steps to be followed include developing a marketing data base--consisting of demographic projections, demand projections, and market share--testing a marketing strategy through experimentation, documenting the expected results and measurement techniques, and calculating the expected return on investments. In dealing with those "impossible-to-measure" cases, such as a physician who is not advertising but finds that a competitor is, a decision tree can help determine whether to advertise and how much to spend by indicating what the return on investment might be.

  20. Workload measurement: diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nuss, Wayne [The Prince Charles Hospital, Chermside, QLD (Australia). Dept. of Medical Imaging

    1993-06-01

    Departments of medical imaging, as with many other service departments in the health industry, are being asked to develop performance indicators. No longer are they assured that annual budget allocations will be forthcoming without justification or some output measurement indicators that will substantiate a claim for a reasonable share of resources. The human resource is the most valuable and the most expensive to any department. This paper provides a brief overview of the research and implementation of a radiographer workload measurement system that was commenced in the Brisbane North Health Region. 2 refs., 10 tabs.

  1. Probability and Measure

    CERN Document Server

    Billingsley, Patrick

    2012-01-01

    Praise for the Third Edition "It is, as far as I'm concerned, among the best books in math ever written....if you are a mathematician and want to have the top reference in probability, this is it." (Amazon.com, January 2006) A complete and comprehensive classic in probability and measure theory Probability and Measure, Anniversary Edition by Patrick Billingsley celebrates the achievements and advancements that have made this book a classic in its field for the past 35 years. Now re-issued in a new style and format, but with the reliable content that the third edition was revered for, this

  2. Preventive measures for emergencies?

    International Nuclear Information System (INIS)

    Calliess, J.

    1990-01-01

    The meeting discussed the new provisions for civil defense on account of the amended Disaster Control Act which had been recently adopted by the Lower House of Parliament. In 6 working groups it was discussed how appropriate and sensible the attempt is to make provisions for civil defence in order to protect the population, and how adequate legislative measures are in the face of true threat and var scenarios. Ethical aspects and aspects of international law were considered, as well as the role of public health and free charitable institutions concering preventive measures in emergencies. (orig. HSCH) [de

  3. Measuring depth in boreholes

    International Nuclear Information System (INIS)

    Hodson, G.M.

    1979-01-01

    This invention relates to a method of determining the depth of rock strata and other features of a borehole. It may be employed with particular advantage when access to the top of the borehole is difficult, for example in underwater operations. A radioactive marker, such as a source of gamma rays, is positioned near the top of the riser of a sub-sea wellhead structure. A radiation detector is lowered between the marker and a radioactive stratum and the length of line supplied is measured on the floating platform. This enables the depth of the stratum to be measured irrespective of tidal variations of the height of the platform. (U.K.)

  4. Rectenna array measurement results

    Science.gov (United States)

    Dickinson, R. M.

    1980-01-01

    The measured performance characteristics of a rectenna array are reviewed and compared to the performance of a single element. It is shown that the performance may be extrapolated from the individual element to that of the collection of elements. Techniques for current and voltage combining were demonstrated. The array performance as a function of various operating parameters is characterized and techniques for overvoltage protection and automatic fault clearing in the array demonstrated. A method for detecting failed elements also exists. Instrumentation for deriving performance effectiveness is described. Measured harmonic radiation patterns and fundamental frequency scattered patterns for a low level illumination rectenna array are presented.

  5. Productivity and Performance Measurement

    DEFF Research Database (Denmark)

    Hald, Kim Sundtoft; Spring, Martin

    This study explores conceptually how performance measurement as discussed in the literature, enables or constrains the ability to manage and improve productivity. It uses an inter-disciplinary literature review to identify five areas of concern relating productivity accounting to the ability...... to improve productivity: “Productivity representation”; “productivity incentives”, “productivity intervention”; “productivity trade-off or synergy” and “productivity strategy and context”. The paper discusses these areas of concern and expands our knowledge of how productivity and performance measurement...

  6. Temperature measurement device

    International Nuclear Information System (INIS)

    Oltman, B.G.; Eckerman, K.F.; Romberg, G.P.; Prepejchal, W.

    1975-01-01

    Thermoluminescent dosimeter (TLD) material is exposed to a known amount of radiation and then exposed to the environment where temperature measurements are to be taken. After a predetermined time period, the TLD material is read in a known manner to determine the amount of radiation energy remaining in the TLD material. The difference between the energy originally stored by irradiation and that remaining after exposure to the temperature ofthe environment is a measure of the average temperature of the environment during the exposure. (U.S.)

  7. Fission gas measuring technology

    International Nuclear Information System (INIS)

    Lee, Hyung Kwon; Kim, Eun Ka; Hwang, Yong Hwa; Lee, Eun Pyo; Chun, Yong Bum; Seo, Ki Seog; Park, Dea Gyu; Chu, Yong Sun; Ahn, Sang Bok.

    1998-02-01

    Safety and economy of nuclear plant are greatly affected by the integrity of nuclear fuels during irradiation reactor core. A series of post-irradiation examination (PIE) including non-destructive and destructive test is to be conducted to evaluate and characterize the nuclear performance. In this report, a principle of the examination equipment to measure and analyse fission gases existing nuclear fuels were described and features of the component and device consisting the fission gas measuring equipment are investigated. (author). 4 refs., 2 tabs., 6 figs

  8. Fission gas measuring technology

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyung Kwon; Kim, Eun Ka; Hwang, Yong Hwa; Lee, Eun Pyo; Chun, Yong Bum; Seo, Ki Seog; Park, Dea Gyu; Chu, Yong Sun; Ahn, Sang Bok

    1998-02-01

    Safety and economy of nuclear plant are greatly affected by the integrity of nuclear fuels during irradiation reactor core. A series of post-irradiation examination (PIE) including non-destructive and destructive test is to be conducted to evaluate and characterize the nuclear performance. In this report, a principle of the examination equipment to measure and analyse fission gases existing nuclear fuels were described and features of the component and device consisting the fission gas measuring equipment are investigated. (author). 4 refs., 2 tabs., 6 figs.

  9. Residual-stress measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ezeilo, A N; Webster, G A [Imperial College, London (United Kingdom); Webster, P J [Salford Univ. (United Kingdom)

    1997-04-01

    Because neutrons can penetrate distances of up to 50 mm in most engineering materials, this makes them unique for establishing residual-stress distributions non-destructively. D1A is particularly suited for through-surface measurements as it does not suffer from instrumental surface aberrations commonly found on multidetector instruments, while D20 is best for fast internal-strain scanning. Two examples for residual-stress measurements in a shot-peened material, and in a weld are presented to demonstrate the attractive features of both instruments. (author).

  10. Creep Measurement Video Extensometer

    Science.gov (United States)

    Jaster, Mark; Vickerman, Mary; Padula, Santo, II; Juhas, John

    2011-01-01

    Understanding material behavior under load is critical to the efficient and accurate design of advanced aircraft and spacecraft. Technologies such as the one disclosed here allow accurate creep measurements to be taken automatically, reducing error. The goal was to develop a non-contact, automated system capable of capturing images that could subsequently be processed to obtain the strain characteristics of these materials during deformation, while maintaining adequate resolution to capture the true deformation response of the material. The measurement system comprises a high-resolution digital camera, computer, and software that work collectively to interpret the image.

  11. Intercalibration of transuranic measurements

    International Nuclear Information System (INIS)

    Fukai, R.; Ballestra, S.; Thein, M.

    1982-01-01

    One of the major objectives of the coordinated research programme on Transuranic Cycling Behaviour in the Marine Environment has been to achieve the comparability of the measurement results among the laboratories from different countries participating in the programme. In order to fulfil this objective, the intercalibration exercises of transuranic measurements using sea water and sediment samples were organized by the Monaco Laboratory within the duration of the programme in 1979-1981. The sediment and sea water samples were collected respectively by the Bhabha Atomic Research Centre of India and the Hydrographic Institute of the Federal Republic of Germany. In the present report the results of these intercalibration exercises are surveyed

  12. Geometric multipartite entanglement measures

    International Nuclear Information System (INIS)

    Paz-Silva, Gerardo A.; Reina, John H.

    2007-01-01

    Within the framework of constructions for quantifying entanglement, we build a natural scenario for the assembly of multipartite entanglement measures based on Hopf bundle-like mappings obtained through Clifford algebra representations. Then, given the non-factorizability of an arbitrary two-qubit density matrix, we give an alternate quantity that allows the construction of two types of entanglement measures based on their arithmetical and geometrical averages over all pairs of qubits in a register of size N, and thus fully characterize its degree and type of entanglement. We find that such an arithmetical average is both additive and strongly super additive

  13. Measuring your radon risk

    International Nuclear Information System (INIS)

    Mackmurdo, R.

    1994-01-01

    In its annual report for 1992/93, the NRPB has warned that tens of thousands of UK employees may be exposed to high levels of radon at work. In addition to those who work underground, employees at risk of radon-induced lung cancer are typically those who spend long periods indoors. This article reviews the implications for all employers especially those in low or unknown levels of radon who resist taking measurements in the belief that by not measuring, they are not liable. (UK)

  14. Measuring pollution prevention

    International Nuclear Information System (INIS)

    Stephan, D.G.; Bridges, J.S.

    1992-01-01

    To assess progress in pollution prevention, estimates or measurements of the amounts of pollution actually prevented have to be made. Such estimates or measurements tell us how far we have come and, possibly, how much farther there is to go in utilizing pollution prevention as a tool for improving environmental quality. They can, theoretically, be used to assess progress on a scale ranging from the individual facility or even the individual process or activity generation wastes to scale as large as a geographical area such as a county, a state or even the United States as a whole. 3 refs

  15. Measuring green jobs?

    DEFF Research Database (Denmark)

    Zandersen, Marianne; Martinsen, Louise

    2012-01-01

    The report reviews the different initiatives aiming to measure aspects of “green” sectors, jobs and technologies. The report discusses whether the statistics collected under the present initiatives aimed at measuring these aspects increase insights into the fundamental questions motivating...... the initiatives. An alternative framework is suggested, as it appears fundamentally impossible to make consistent frameworks for a division of the economy into “green” and “non-green” activities. The analysis has been carried out during the period September 2011 – March 2012 by Vista Analysis AS, Gaia Consulting...

  16. Simulations with complex measure

    International Nuclear Information System (INIS)

    Markham, J.K.; Kieu, T.D.

    1997-01-01

    A method is proposed to handle the sign problem in the simulation of systems having indefinite or complex-valued measures. In general, this new approach, which is based on renormalisation blocking, is shown to yield statistical errors smaller that the crude Monte Carlo method using absolute values of the original measures. The improved method is applied to the 2D Ising model with temperature generalised to take on complex values. It is also adapted to implement Monte Carlo Renormalisation Group calculations of the magnetic and thermal critical exponents. 10 refs., 4 tabs., 7 figs

  17. Transverse betatron tune measurements

    International Nuclear Information System (INIS)

    Serio, M.

    1989-01-01

    In this paper the concept of the betatron tune and the techniques to measure it are discussed. The smooth approximation is introduced along with the terminology of betatron oscillations, phase advance and tune. Single particle and beam spectra in the presence of synchro-betatron oscillations are treated with emphasis on the consequences of sampling the beam position. After a general presentation of various kinds of beam position monitors and transverse kickers, the time domain and frequency domain analysis of the beam response to a transverse excitation are discussed and several methods and applications of the tune measurements are listed

  18. Liquid metal level measurement

    International Nuclear Information System (INIS)

    Hale, J.C.; Leyland, K.S.

    1982-01-01

    A liquid metal level indicator is described which can be used to measure, in a stainless steel tank, the level of a nuclear reactor coolant such as sodium. The instrument, which is based on the eddy current induction effect, gives readings over substantially the full depth of the tank and indicates the sense of change of level. (U.K.)

  19. Health Physics Measurements Services

    Energy Technology Data Exchange (ETDEWEB)

    Carchon, R

    2001-04-01

    SCK-CEN's programme on health physics measurements includes various activities in dosimetry, calibration , instrumentation , gamma-ray spectrometry, whole body counting , the preparation of standard sources, non-destructive assay and the maintenance of Euratom Fork detectors. Main achievements in these topical areas in 2000 are summarised.

  20. Dialogue scanning measuring systems

    International Nuclear Information System (INIS)

    Borodyuk, V.P.; Shkundenkov, V.N.

    1985-01-01

    The main developments of scanning measuring systems intended for mass precision processsing of films in nuclear physics problems and in related fields are reviewed. A special attention is paid to the problem of creation of dialogue systems which permit to simlify the development of control computer software