WorldWideScience

Sample records for measured relative intensity

  1. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Compartir For more help with what counts as aerobic activity, watch this video: Windows Media Player, 4: ... ways to understand and measure the intensity of aerobic activity: relative intensity and absolute intensity. Relative Intensity ...

  2. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... using relative intensity, people pay attention to how physical activity affects their heart rate and breathing. The talk test is a simple way to measure relative intensity. ...

  3. Measurement of relative intensities of L-shell x-rays in some high-Z elements

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, S; Mittal, R; Allawadhi, K L; Sood, B S [Punjabi Univ., Patiala (India). Nuclear Science Labs.

    1982-10-14

    The L-shell x-ray relative intensities I(Lsub(..cap alpha..))/I(Lsub(l)),I(Lsub(..cap alpha..))/I(Lsub(..beta..)) and I(Lsub(..cap alpha..))/I(Lsub(..gamma..)) for U, Th, Pb and ratios I(Lsub(..cap alpha..+l))/I(Lsub(..beta..)) and I(Lsub(..cap alpha..+l))/I(Lsub(..gamma..)) for W have been measured. The L-shell electrons are excited by 59.57 keV gamma rays from /sup 241/Am and the fluorescent L-shell x-ray intensities are measured with a Si(Li) detector. The experimental results are found to agree well with theory.

  4. Measurement of relative intensities of L-shell X-rays of some heavy elements using Cd-109 radioisotope source

    International Nuclear Information System (INIS)

    Darko, J.B.; Tetteh, G.K.

    1992-01-01

    The relative L-shell x-ray intensities of Sm, W, Ir, Au, Hg, Pb and U were measured using a Cd-109 radioisotope source and a Si(Li) detector. The measured relative intensities were compared with the theoretically calculated values due to Scofield, computed for the present excitation energy of 22.6 keV. The experimental results were found to agree with theory in most cases. (author)

  5. Measurement of relative intensities of L-shell X-rays of some heavy elements using Cd-109 radioisotope source

    Energy Technology Data Exchange (ETDEWEB)

    Darko, J.B.; Tetteh, G.K. (Ghana Univ., Legon (Ghana). Dept. of Physics)

    The relative L-shell x-ray intensities of Sm, W, Ir, Au, Hg, Pb and U were measured using a Cd-109 radioisotope source and a Si(Li) detector. The measured relative intensities were compared with the theoretically calculated values due to Scofield, computed for the present excitation energy of 22.6 keV. The experimental results were found to agree with theory in most cases. (author).

  6. Provision of protein and energy in relation to measured requirements in intensive care patients

    DEFF Research Database (Denmark)

    Allingstrup, Matilde Jo; Esmailzadeh, Negar; Knudsen, Anne Wilkens

    2012-01-01

    , also when adjusted for baseline prognostic variables (APACHE II, SOFA scores and age). Provision of energy, measured resting energy expenditure or energy and nitrogen balance was not related to mortality. The possible cause-effect relationship is discussed after a more detailed analysis of the initial......BACKGROUND & AIMS: Adequacy of nutritional support in intensive care patients is still a matter of investigation. This study aimed to relate mortality to provision, measured requirements and balances for energy and protein in ICU patients. DESIGN: Prospective observational cohort study of 113 ICU...... part of the admission. CONCLUSION: In these severely ill ICU patients, a higher provision of protein and amino acids was associated with a lower mortality. This was not the case for provision of energy or measured resting energy expenditure or energy or nitrogen balances. The hypothesis that higher...

  7. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... 45 David, Age 65 Harold, Age 67 Data & Statistics Facts About Physical Activity Data, Trends and Maps ... relative intensity and absolute intensity. Relative Intensity The level of effort required by a person to do ...

  8. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Older Adults Overcoming Barriers Measuring Physical Activity Intensity Target Heart Rate & Estimated Maximum Heart Rate Perceived Exertion ( ... a heavy backpack Other Methods of Measuring Intensity Target Heart Rate and Estimated Maximum Heart Rate Perceived ...

  9. Fatigue in Intensive Care Nurses and Related Factors.

    Science.gov (United States)

    Çelik, Sevim; Taşdemir, Nurten; Kurt, Aylin; İlgezdi, Ebru; Kubalas, Özge

    2017-10-01

    Fatigue negatively affects the performance of intensive care nurses. Factors contributing to the fatigue experienced by nurses include lifestyle, psychological status, work organization and sleep problems. To determine the level of fatigue among nurses working in intensive care units and the related factors. This descriptive study was conducted with 102 nurses working in intensive care units in the West Black Sea Region of Turkey. Data were collected between February and May 2014 using a personal information form, the Visual Analogue Scale for Fatigue (VAS-F), the Hospital Anxiety and Depression Scale and the Pittsburg Sleep Quality Index. The intensive care nurses in the study were found to be experiencing fatigue. Significant correlations were observed between scores on the VAS-F Fatigue and anxiety (p=0.01), depression (p=0.002), and sleep quality (pnurses' levels of fatigue. These results can be of benefit in taking measures which may be used to reduce fatigue in nurses, especially the fatigue related to work organization and social life.

  10. Dispersion relation and relative intensity for double-plasmon satellites

    International Nuclear Information System (INIS)

    Srivastava, K.S.; Shiv Singh; Harsh, O.K.

    1981-01-01

    An expression for the dispersion relation and the relative intensity of double-plasmon oscillations and satellites has been derived by extending the dispersion relation and the extended Bohm and Pines Hamiltonian to second order. The calculated value of the relative intensity of the double-plasmon satellite for Be agrees fairly well with the value observed experimentally by other workers. (orig.)

  11. Quantization analysis of speckle intensity measurements for phase retrieval

    DEFF Research Database (Denmark)

    Maallo, Anne Margarette S.; Almoro, Percival F.; Hanson, Steen Grüner

    2010-01-01

    Speckle intensity measurements utilized for phase retrieval (PR) are sequentially taken with a digital camera, which introduces quantization error that diminishes the signal quality. Influences of quantization on the speckle intensity distribution and PR are investigated numerically...... and experimentally in the static wavefront sensing setup. Resultsshowthat 3 to 4 bits are adequate to represent the speckle intensities and yield acceptable reconstructions at relatively fast convergence rates. Computer memory requirements may be eased down by 2.4 times if a 4 bit instead of an 8 bit camera is used...

  12. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Healthy Weight Breastfeeding Micronutrient Malnutrition State and Local Programs Measuring Physical Activity Intensity Recommend on Facebook Tweet Share Compartir For more help with what ...

  13. Fast and thermal neutron intensity measurements at the KFUPM PGNAA setup

    CERN Document Server

    Al-Jarallah, M I; Fazal-Ur-Rehman; Abu-Jarad, F A

    2002-01-01

    Fast and thermal neutron intensity distributions have been measured at an accelerator based prompt gamma ray neutron activation analysis (PGNAA) setup. The setup is built at the 350 keV accelerator laboratory of King Fahd University of Petroleum and Minerals (KFUPM). The setup is mainly designed to carry out PGNAA elemental analysis via thermal neutron capture. In this study relative intensity of fast and thermal neutrons was measured as a function of the PGNAA moderator assembly parameters using nuclear track detectors (NTDs). The relative intensity of the neutrons was measured inside the sample region as a function of front moderator thickness as well as sample length. Measurements were carried out at the KFUPM 350 keV accelerator using 2.8 MeV pulsed neutron beam from D(d,n) reaction. The pulsed deuteron beam with 5 ns pulse width and 30 kHz frequency was used to produce neutrons. Experimental results were compared with results of Monte Carlo design calculations of the PGNAA setup. A good agreement has bee...

  14. Fast and thermal neutron intensity measurements at the KFUPM PGNAA setup

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jarallah, M.I.; Naqvi, A.A. E-mail: aanaqvi@kfupm.edu.sa; Fazal-ur-Rehman; Abu-jarad, F

    2002-10-01

    Fast and thermal neutron intensity distributions have been measured at an accelerator based prompt gamma ray neutron activation analysis (PGNAA) setup. The setup is built at the 350 keV accelerator laboratory of King Fahd University of Petroleum and Minerals (KFUPM). The setup is mainly designed to carry out PGNAA elemental analysis via thermal neutron capture. In this study relative intensity of fast and thermal neutrons was measured as a function of the PGNAA moderator assembly parameters using nuclear track detectors (NTDs). The relative intensity of the neutrons was measured inside the sample region as a function of front moderator thickness as well as sample length. Measurements were carried out at the KFUPM 350 keV accelerator using 2.8 MeV pulsed neutron beam from D(d,n) reaction. The pulsed deuteron beam with 5 ns pulse width and 30 kHz frequency was used to produce neutrons. Experimental results were compared with results of Monte Carlo design calculations of the PGNAA setup. A good agreement has been found between the experimental results and the calculations.

  15. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... 10 miles per hour or faster Jumping rope Heavy gardening (continuous digging or hoeing) Hiking uphill or with a heavy backpack Other Methods of Measuring Intensity Target Heart ...

  16. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Measuring Intensity Target Heart Rate and Estimated Maximum Heart Rate Perceived Exertion (Borg Rating of Perceived Exertion Scale) Get Email Updates To receive email updates about this page, enter your email ... ...

  17. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Adults Need More Physical Activity MMWR Data Highlights State Indicator Report on Physical Activity, 2014 Recommendations & Guidelines ... Activity Overweight & Obesity Healthy Weight Breastfeeding Micronutrient Malnutrition State and Local Programs Measuring Physical Activity Intensity Recommend ...

  18. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Local Programs Measuring Physical Activity Intensity Recommend on Facebook Tweet Share Compartir For more help with what ... RSS ABOUT About CDC Jobs Funding LEGAL Policies Privacy FOIA No Fear Act OIG 1600 Clifton Road ...

  19. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Hiking uphill or with a heavy backpack Other Methods of Measuring Intensity Target Heart Rate and Estimated ... Help: How do I view different file formats (PDF, DOC, PPT, MPEG) on this site? Adobe PDF ...

  20. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Hiking uphill or with a heavy backpack Other Methods of Measuring Intensity Target Heart Rate and Estimated ... YouTube Instagram Listen Watch RSS ABOUT About CDC Jobs Funding LEGAL Policies Privacy FOIA No Fear Act ...

  1. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Adults Needs for Children What Counts Needs for Older Adults Needs for Pregnant or Postpartum Women Physical Activity & ... to Your Life Activities for Children Activities for Older Adults Overcoming Barriers Measuring Physical Activity Intensity Target Heart ...

  2. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... to Your Life Activities for Children Activities for Older Adults Overcoming Barriers ... required by a person to do an activity. When using relative intensity, people pay attention to how physical activity affects their ...

  3. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... level of effort required by a person to do an activity. When using relative intensity, people pay ... State and Local Programs File Formats Help: How do I view different file formats (PDF, DOC, PPT, ...

  4. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... an activity. When using relative intensity, people pay attention to how physical activity affects their heart rate ... Physical Activity Overweight & Obesity Healthy Weight Breastfeeding Micronutrient Malnutrition State and Local Programs File Formats Help: How ...

  5. Constrained Maximum Likelihood Estimation of Relative Abundances of Protein Conformation in a Heterogeneous Mixture from Small Angle X-Ray Scattering Intensity Measurements

    Science.gov (United States)

    Onuk, A. Emre; Akcakaya, Murat; Bardhan, Jaydeep P.; Erdogmus, Deniz; Brooks, Dana H.; Makowski, Lee

    2015-01-01

    In this paper, we describe a model for maximum likelihood estimation (MLE) of the relative abundances of different conformations of a protein in a heterogeneous mixture from small angle X-ray scattering (SAXS) intensities. To consider cases where the solution includes intermediate or unknown conformations, we develop a subset selection method based on k-means clustering and the Cramér-Rao bound on the mixture coefficient estimation error to find a sparse basis set that represents the space spanned by the measured SAXS intensities of the known conformations of a protein. Then, using the selected basis set and the assumptions on the model for the intensity measurements, we show that the MLE model can be expressed as a constrained convex optimization problem. Employing the adenylate kinase (ADK) protein and its known conformations as an example, and using Monte Carlo simulations, we demonstrate the performance of the proposed estimation scheme. Here, although we use 45 crystallographically determined experimental structures and we could generate many more using, for instance, molecular dynamics calculations, the clustering technique indicates that the data cannot support the determination of relative abundances for more than 5 conformations. The estimation of this maximum number of conformations is intrinsic to the methodology we have used here. PMID:26924916

  6. Retrieval of tropospheric NO2 using the MAX-DOAS method combined with relative intensity measurements for aerosol correction

    Directory of Open Access Journals (Sweden)

    P. F. Levelt

    2010-10-01

    Full Text Available Multi-Axis Differential Optical Absorption Spectroscopy (MAX-DOAS is a technique to measure trace gas amounts in the lower troposphere from ground-based scattered sunlight observations. MAX-DOAS observations are especially suitable for validation of tropospheric trace gas observations from satellite, since they have a representative range of several kilometers, both in the horizontal and in the vertical dimension. A two-step retrieval scheme is presented here, to derive aerosol corrected tropospheric NO2 columns from MAX-DOAS observations. In a first step, boundary layer aerosols, characterized in terms of aerosol optical thickness (AOT, are estimated from relative intensity observations, which are defined as the ratio of the sky radiance at elevation α and the sky radiance in the zenith. Relative intensity measurements have the advantage of a strong dependence on boundary layer AOT and almost no dependence on boundary layer height. In a second step, tropospheric NO2 columns are derived from differential slant columns, based on AOT-dependent air mass factors. This two-step retrieval scheme was applied to cloud free periods in a twelve month data set of observations in De Bilt, The Netherlands. In a comparison with AERONET (Cabauw site a mean difference in AOT (AERONET minus MAX-DOAS of −0.01±0.08 was found, and a correlation of 0.85. Tropospheric-NO2 columns were compared with OMI-satellite tropospheric NO2. For ground-based observations restricted to uncertainties below 10%, no significant difference was found, and a correlation of 0.88.

  7. Calculation and measurement of the intensity distribution of 60Co radiation behind block filters

    International Nuclear Information System (INIS)

    Gerlach, R.; Kranepuhl, H.; Salewski, D.

    1987-01-01

    A method for determining the absorption length in block filters with non-focussing edges is described. It accounts for geometric parameters as source diameter, source-surface-distance and the position of the absorber relative to the central ray. The model was checked by intensity measurements. Behind the absorber as well as in the penumbra regions good agreement between calculation and measurement of the intensity distribution was observed. (author)

  8. Measures of Competitive Intensity – Analysis Based on Literature Review

    Directory of Open Access Journals (Sweden)

    Dariusz Kwieciński

    2017-03-01

    Full Text Available Purpose: To systematize the existing approaches and tools used for measuring competitive intensity. Methodology: Systematic literature review along with critical literature review. Findings: Identifcation of two main approaches to measuring competition intensity: the frst pertains to research based on experts’ opinions and involves the use of questionnaires (primary sources, while the second is based on structural variables used with a variety of indexes (secondary sources. In addition, variables applied for the purpose of measuring the intensity of competition are divided into structural and behavioural. Research implications: Research implications are two-fold. Firstly, a distinction is made between various types of existing approaches to measuring competitive intensity. Secondly, research is carried out, inter alia, with regard to the actual object of certain measures, as opposed to their object stemming from commonly accepted defnitions. Practical implications: The issue of measuring competition intensity occupies a prominent place in the discussion on the effectiveness of inter-organizational relationships. The fndings outlined in this paper may help managers to develop/adopt the right approach supporting their strategic decisions. Originality: The paper provides a complex review of the existing methods and measures of competitive intensity. It systematizes recent knowledge about competitive intensity measurements.

  9. Sound intensity and its measurement

    DEFF Research Database (Denmark)

    Jacobsen, Finn

    1997-01-01

    The paper summarises the basic theory of sound intensity and its measurement and gives an overview of the state of the art with particular emphasis on recent developments in the field. Eighty references are given, most of which to literature published in the past two years. The paper describes...

  10. The relative-intensity method of X-ray fluorescence analysis and its application to soils and rocks

    International Nuclear Information System (INIS)

    Childs, C.W.; Furkert, R.J.

    1974-01-01

    The relative-intensity X-ray fluorescence method of analysis of rock and soil samples has been investigated and compared with the net-intensity method. Strong, coherently scattered radiation originating from the X-ray tube is shown to be preferable to background radiation as an internal standard, and scattered radiation measured at one wavelength can usefully be applied in the determination of several elements. When the concentrations of an element in two soil samples of different composition (for example concretions and the soil adjacent to them) are compared, the ratio of the relative intensities may be different from the ratio of net intensities by a factor of about two. The concentrations of manganese in thirteen standard rock samples determined by the relative-intensity method are within or very close to the ranges of values reported previously

  11. Serial measurement of relative changes in net magnetization, 1

    International Nuclear Information System (INIS)

    Kaneoke, Yoshiki; Furuse, Masahiro; Izawa, Akira.

    1993-01-01

    We assessed to what extent relative changes in net magnetization could be measured with the low field (0.043 T) MR imager. By the procedure to stabilize the whole MR imager hardware, we could measure the minute relative changes of the net magnetization (less than 1%) from the forearm presumably related to blood volume change. This method may be useful to measure physiological changes of blood volume in various human tissues though we need further development of hardware to measure minute relative changes in MR signal intensity with small volume selection. (author)

  12. Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, P. [Department of Science Education, Faculty of Education, Erzincan University, 24030 Erzincan (Turkey)], E-mail: pasayalcin@hotmail.com; Porikli, S.; Kurucu, Y.; Sahin, Y. [Department of Physics, Faculty of Sciences, Atatuerk University, 25240 Erzurum (Turkey)

    2008-05-22

    The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available experimental results.

  13. Measurements of acoustic pressure at high amplitudes and intensities

    International Nuclear Information System (INIS)

    Crum, L A; Bailey, M R; Kaczkowski, P; McAteer, J A; Pishchalnikov, Y A; Sapozhnikov, O A

    2004-01-01

    In our research group, we desire measurements of the large pressure amplitudes generated by the shock waves used in shock wave lithotripsy (SWL) and the large acoustic intensities used in High Intensity Focused Ultrasound (HIFU). Conventional piezoelectric or PVDF hydrophones can not be used for such measurements as they are damaged either by cavitation, in SWL applications, or heat, in HIFU applications. In order to circumvent these difficulties, we have utilized optical fiber hydrophones in SWL that do not cavitate, and small glass probes and a scattering technique for measurements of large HIFU intensities. Descriptions of these techniques will be given as well as some typical data

  14. Radar and photometric measurements of an intense type A red aurora

    Science.gov (United States)

    Robinson, R. M.; Mende, S. B.; Vondrak, R. R.; Kozyra, J. U.; Nagy, A. F.

    1985-01-01

    On the evening of March 5, 1981, an intense, type A red aurora appeared over southern Alaska. Radar and photometric measurements were made of the aurora from the Chatanika radar site. The line of sight intensity of the 630.0-nm emissions exceeded 150 kR and was accompanied by enhanced emissions at 486.1 and 427.8 nm. The Chatanika radar measured electron densities of 10 to the 6th per cu cm and electron temperatures of 6000 K at an altitude of 400 km and an invariant latitude of 59 deg in association with the aurora. Comparison of optical and radar measurements indicated that the 630.0-nm emissions were produced to a large degree by thermal excitation of O(1D) in the region of high electron temperatures and densities. Model calculations indicate that the observed density and temperature enhancements and the related optical emissions were the results of a relatively short duration (5-10 min) pulse of precipitating, low-energy (about 30 eV) electrons. Whereas conventional stable auroral red arcs are associated with a gradual decrease in ring current energy density during the recovery phase of a magnetic storm, the type A red aurora may be produced by impulsive ring current energy loss during the main phase.

  15. Lessons learnt from the first EMEP intensive measurement periods

    Directory of Open Access Journals (Sweden)

    W. Aas

    2012-09-01

    Full Text Available The first EMEP intensive measurement periods were held in June 2006 and January 2007. The measurements aimed to characterize the aerosol chemical compositions, including the gas/aerosol partitioning of inorganic compounds. The measurement program during these periods included daily or hourly measurements of the secondary inorganic components, with additional measurements of elemental- and organic carbon (EC and OC and mineral dust in PM1, PM2.5 and PM10. These measurements have provided extended knowledge regarding the composition of particulate matter and the temporal and spatial variability of PM, as well as an extended database for the assessment of chemical transport models. This paper summarise the first experiences of making use of measurements from the first EMEP intensive measurement periods along with EMEP model results from the updated model version to characterise aerosol composition. We investigated how the PM chemical composition varies between the summer and the winter month and geographically.

    The observation and model data are in general agreement regarding the main features of PM10 and PM2.5 composition and the relative contribution of different components, though the EMEP model tends to give slightly lower estimates of PM10 and PM2.5 compared to measurements. The intensive measurement data has identified areas where improvements are needed. Hourly concurrent measurements of gaseous and particulate components for the first time facilitated testing of modelled diurnal variability of the gas/aerosol partitioning of nitrogen species. In general, the modelled diurnal cycles of nitrate and ammonium aerosols are in fair agreement with the measurements, but the diurnal variability of ammonia is not well captured. The largest differences between model and observations of aerosol mass are seen in Italy during winter, which to a large extent may be

  16. Phase shift errors in the theory and practice of surface intensity measurements

    Science.gov (United States)

    Mcgary, M. C.; Crocker, M. J.

    1982-01-01

    The surface acoustical intensity method (sometimes known as the microphone-accelerometer cross-spectral method) is a relatively new noise source/path identification tool. Several researchers have had difficulties implementing this method because of instrumentation phase mis-match. A simple technique for measuring and correcting instrumentation phase mis-match has been developed. This new technique has been tested recently on a noise source identification problem of practical interest. The results of the experiments indicate that the surface acoustic intensity method produces reliable data and can be applied to a variety of noise source/path problems.

  17. Measurement of intensity distribution of CSR in LEBRA PXR beamline

    International Nuclear Information System (INIS)

    Nakao, Keisuke; Sakai, Takeshi; Hayakawa, Ken; Tanaka, Toshinari; Hayakawa, Yasushi; Nogami, Kyoko; Inagaki, Manabu; Sei, Norihiro

    2014-01-01

    Last year, the intensity of Coherent Synchrotron Radiation (CSR) in LEBRA PXR beamline was measured. As a result, it turned out that the intensity of CSR was stronger than anticipation. It is suggested that Coherent Edge Radiation (CER) is mixed with CSR. Then, in order to confirm whether CER is contained, the intensity distribution of CSR was measured. The result of the experiment is reported in this paper. (author)

  18. A prospective window into medical device-related pressure ulcers in intensive care.

    Science.gov (United States)

    Coyer, Fiona M; Stotts, Nancy A; Blackman, Virginia Schmied

    2014-12-01

    The aim of this study was to determine the prevalence, severity, location, aetiology, treatment and healing of medical device-related pressure ulcers (PUs) in intensive care patients for up to 7 days. A prospective repeated measures study design was used. Patients in six intensive care units of two major medical centres, one each in Australia and the USA, were screened 1 day per month for 6 months. Those with device-related ulcers were followed daily for up to 7 days. The outcome measures were device-related ulcer prevalence, pain, infection, treatment and healing. Fifteen of 483 patients had device-related ulcers and 9 of 15 with 11 ulcers were followed beyond screening. Their mean age was 60·5 years, and most were men, overweight and at increased risk of PU. Endotracheal (ET) and nasogastric (NG) tubes were the cause of most device-related ulcers. Repositioning was the most frequent treatment. Four of 11 ulcers healed within the 7-day observation period. In conclusion, device-related ulcer prevalence was 3·1%, similar to that reported in the limited literature available, indicating an ongoing problem. Systematic assessment and repositioning of devices are the mainstays of care. We recommend continued prevalence determination and that nurses remain vigilant to prevent device-related ulcers, especially in patients with NG and ET tubes. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  19. Price-related sensitivities of greenhouse gas intensity targets

    International Nuclear Information System (INIS)

    Muller, Benito; Muller-Furstenberger, Georg

    2003-12-01

    Greenhouse gas intensities are an appealing tool to foster abatement without imposing constraints on economic growth. This paper shows, however, that the computation of intensities is subject to some significant statistical and conceptual problems which relate to the inflation proofing of GDP growth. It is shown that the choice of price-index, the updating of quantity weights and the choice of base year prices can have a significant impact upon the commitment of intensity targets

  20. Measuring the Carbon Intensity of the South African Economy

    DEFF Research Database (Denmark)

    Arndt, Channing; Davies, Rob; Makrelov, Konstantin

    2013-01-01

    We estimate the carbon intensity of industries, products and households in South Africa using data from a high resolution supply-use table. Direct and indirect carbon usage is measured using multiplier methods that capture inter-industry linkages and multi-product supply chains. Carbon intensity ...... or poorer households. Seven percent of emissions arise through marketing margins, implying that carbon pricing should be accompanied by supporting public policies and investments.......We estimate the carbon intensity of industries, products and households in South Africa using data from a high resolution supply-use table. Direct and indirect carbon usage is measured using multiplier methods that capture inter-industry linkages and multi-product supply chains. Carbon intensity...... is found to be high for exports but low for major employing sectors. Middle-income households are the most carbon-intensive consumers. These results suggest that carbon pricing policies (without border tax adjustments) would adversely affect export earnings, but should not disproportionately hurt workers...

  1. Facial feature tracking: a psychophysiological measure to assess exercise intensity?

    Science.gov (United States)

    Miles, Kathleen H; Clark, Bradley; Périard, Julien D; Goecke, Roland; Thompson, Kevin G

    2018-04-01

    The primary aim of this study was to determine whether facial feature tracking reliably measures changes in facial movement across varying exercise intensities. Fifteen cyclists completed three, incremental intensity, cycling trials to exhaustion while their faces were recorded with video cameras. Facial feature tracking was found to be a moderately reliable measure of facial movement during incremental intensity cycling (intra-class correlation coefficient = 0.65-0.68). Facial movement (whole face (WF), upper face (UF), lower face (LF) and head movement (HM)) increased with exercise intensity, from lactate threshold one (LT1) until attainment of maximal aerobic power (MAP) (WF 3464 ± 3364mm, P exercise intensities (UF minus LF at: LT1, 1048 ± 383mm; LT2, 1208 ± 611mm; MAP, 1401 ± 712mm; P exercise intensity.

  2. Solar intensity measurement using a thermoelectric module; experimental study and mathematical modeling

    International Nuclear Information System (INIS)

    Rahbar, Nader; Asadi, Amin

    2016-01-01

    Highlights: • Solar intensity could be explained as a linear function of voltage and ambient temperature. • The maximum output voltage is approximately 120 mV which was occurred in midday. • The average value of the heat-sink thermal resistance could be measured with this device. • The average values of total heat transfer coefficients could be measured with this device. • Two correlations were proposed to predict the solar intensity with the accuracy of 10%. - Abstract: The present study is intended to design, manufacture, and modeling an inexpensive pyranometer using a thermoelectric module. The governing equations relating the solar intensity, output voltage, and ambient temperature have been derived by applying the mathematical and thermodynamic models. According to the thermodynamics modeling, the output voltage is a function of solar intensity, ambient temperature, internal parameters of thermoelectric module, convection and radiation coefficients, and geometrical characteristics of the setup. Moreover, the solar intensity can be considered as a linear function of voltage and ambient temperature within an acceptable range of accuracy. The experiments have been carried out on a typical winter day under climatic conditions of Semnan (35°33′N, 53°23′E), Iran. The results also indicated that the output voltage is dependent on the solar intensity and its maximum value was 120 mV. Finally, based on the experimental results, two correlations, with the accuracy of 10%, have been proposed to predict the solar intensity as a function of output voltage and ambient temperature. The average values of total heat transfer coefficient and thermal resistance of the heat-sink have been also calculated according to the thermodynamic modeling and experimental results.

  3. A note on measurement of sound pressure with intensity probes

    DEFF Research Database (Denmark)

    Juhl, Peter; Jacobsen, Finn

    2004-01-01

    be improved under a variety of realistic sound field conditions by applying a different weighting of the two pressure signals from the probe. The improved intensity probe can measure the sound pressure more accurately at high frequencies than an ordinary sound intensity probe or an ordinary sound level meter......The effect of scattering and diffraction on measurement of sound pressure with "two-microphone" sound intensity probes is examined using an axisymmetric boundary element model of the probe. Whereas it has been shown a few years ago that the sound intensity estimated with a two-microphone probe...... is reliable up to 10 kHz when using 0.5 in. microphones in the usual face-to-face arrangement separated by a 12 mm spacer, the sound pressure measured with the same instrument will typically be underestimated at high frequencies. It is shown in this paper that the estimate of the sound pressure can...

  4. Age-related patterns of vigorous-intensity physical activity in youth

    DEFF Research Database (Denmark)

    Corder, Kirsten; Sharp, Stephen J; Atkin, Andrew J

    2016-01-01

    the relative reduction was 6.0% (5.6%, 6.4%). The age-related decrease in vigorous-intensity activity remained after adjustment for moderate activity. A larger age-related decrease in vigorous activity was observed for girls (- 10.7%) versus boys (- 2.9%), non-white (- 12.9% to - 9.4%) versus white individuals......Physical activity declines during youth but most evidence reports on combined moderate and vigorous-intensity physical activity. We investigated how vigorous-intensity activity varies with age. Cross-sectional data from 24,025 participants (5.0-18.0 y; from 20 studies in 10 countries obtained 2008...... (- 6.1%), lowest maternal education (high school (- 2.0%)) versus college/university (ns) and for overweight/obese (- 6.1%) versus healthy-weight participants (- 8.1%). In addition to larger annual decreases in vigorous-intensity activity, overweight/obese individuals, girls and North Americans had...

  5. Consistency of neutron and proton capture intensity standards new relative intensities for 56Co, 66Ga decay and 35Cl(n,γ) reaction gamma rays

    International Nuclear Information System (INIS)

    Molnar, G.L.; Revay, Z.; Belgya, T.

    2000-01-01

    The equivalence of efficiency determination procedures based on neutron and proton capture lines has been verified and the deviation of high-energy efficiency from linearity confirmed. The new, accurate relative intensities for 56 Co and 66 Ga extend the range of secondary radioactive standards up to 4.8 MeV. Extreme care has to be taken with any high-energy intensity value obtained in the past with the help of 56 Co and 66 Ga calibration sources, and corrections have to be made using the present data of high accuracy. Relative intensities have also been improved for the 35 Cl(n,γ) reaction, a useful secondary standard in a wide energy range, between 0.3-8.5 MeV. The new data are supported by other most recent measurements of a slightly lower precision

  6. An intensity-monitoring technique for measuring ellipsometric transients

    NARCIS (Netherlands)

    Droog, J.M.M.; Bootsma, G.A.

    1979-01-01

    Intensity-monitoring techniques make possible the measurement of rapid changes in the ellipsometric parameters. Methods used hitherto have been suitable for measuring slight changes only and require prior knowledge of the Δ and Ψ values for the initial surface. It is shown that larger changes can

  7. Issues of work intensity, pace, and sustainability in relation to work context and nutritional status.

    Science.gov (United States)

    Panter-Brick, Catherine

    2003-01-01

    This article raises issues about work intensity, pace, and sustainability during physical activity, focusing attention on the nature of work in labor-intensive societies, the management of exertion in habitual tasks, and the health and broad socioeconomic correlates of alternative ways to regulate work patterns. At the heart of this review are concerns to document human adaptability (in terms of the physical and behavioral management of heavy work) and to renew debate regarding the conceptualization and measurement of work intensity (variously evaluated in absolute or relative terms, as indexed by oxygen consumption, energy expenditure, percentage maximal work capacity, heart rate elevation, time and motion indicators, or physiological cost). Three questions are examined: Is heavy work primarily a matter of time or energy intensity? How is heavy work habitually sustained? What is the bigger picture relating work performance to work context and to nutritional or health status? It is argued that many arduous activities, such as carrying loads, demand endurance over time rather than intensive effort per unit time, and that work pace management lies in regulating both the rate of work and the time in rest during physical activity. Furthermore, strategies that maximize long-term endurance (adopted by "tortoises") and those that maximize short-term productivity (adopted by "hares") are appropriate to different work contexts (e.g., a subsistence or wage-labor economy) and suit individuals with different health status and ability. Thus, work intensity is an important aspect of the links between physical activity, health, productivity, and society, as noted in literature reviewing objectives for sustainable development and public health messages for disease risk management. These areas of scholarship are underresearched, partly because consensus has been slow in agreeing on which are the best measures of work pace and work intensity for use in field situations, and which

  8. X-ray polarization measurements at relativistic laser intensities

    International Nuclear Information System (INIS)

    Beiersdorfer, P.; Shepherd, R.; Mancini, R.C.

    2004-01-01

    An effort has been started to measure the short pulse laser absorption and energy partition at relativistic laser intensities up to 10 21 W/cm 2 . Plasma polarization spectroscopy is expected to play an important role in determining fast electron generation and measuring the electron distribution function. (author)

  9. A conceptual framework for analysing and measuring land-use intensity

    DEFF Research Database (Denmark)

    Erb, Karl-Heinz; Haberl, Helmut; Jepsen, Martin Rudbeck

    2013-01-01

    Large knowledge gaps currently exist that limit our ability to understand and characterise dynamics and patterns of land-use intensity: in particular, a comprehensive conceptual framework and a system of measurement are lacking. This situation hampers the development of a sound understanding...... of the mechanisms, determinants, and constraints underlying changes in land-use intensity. On the basis of a review of approaches for studying land-use intensity, we propose a conceptual framework to quantify and analyse land-use intensity. This framework integrates three dimensions: (a) input intensity, (b) output...

  10. Simultaneous reconstruction, segmentation, and edge enhancement of relatively piecewise continuous images with intensity-level information

    International Nuclear Information System (INIS)

    Liang, Z.; Jaszczak, R.; Coleman, R.; Johnson, V.

    1991-01-01

    A multinomial image model is proposed which uses intensity-level information for reconstruction of contiguous image regions. The intensity-level information assumes that image intensities are relatively constant within contiguous regions over the image-pixel array and that intensity levels of these regions are determined either empirically or theoretically by information criteria. These conditions may be valid, for example, for cardiac blood-pool imaging, where the intensity levels (or radionuclide activities) of myocardium, blood-pool, and background regions are distinct and the activities within each region of muscle, blood, or background are relatively uniform. To test the model, a mathematical phantom over a 64x64 array was constructed. The phantom had three contiguous regions. Each region had a different intensity level. Measurements from the phantom were simulated using an emission-tomography geometry. Fifty projections were generated over 180 degree, with 64 equally spaced parallel rays per projection. Projection data were randomized to contain Poisson noise. Image reconstructions were performed using an iterative maximum a posteriori probability procedure. The contiguous regions corresponding to the three intensity levels were automatically segmented. Simultaneously, the edges of the regions were sharpened. Noise in the reconstructed images was significantly suppressed. Convergence of the iterative procedure to the phantom was observed. Compared with maximum likelihood and filtered-backprojection approaches, the results obtained using the maximum a posteriori probability with the intensity-level information demonstrated qualitative and quantitative improvement in localizing the regions of varying intensities

  11. On the continuous measurement of the cosmic-ray intensity, 2

    International Nuclear Information System (INIS)

    Ishida, Yoshio; Kanno, Tsunekichi

    1974-01-01

    Since November 1971, the cosmic ray neutron intensity has been measured continuously with 3NM-64 neutron monitor at Fukushima University (140 0 29'E geographic longitude, 37 0 45'N geographic latitude, 27.6 0 N geomagnetic latitude and 10.55 GV cut-off rigidity). After the neutron monitor had been operated during the period of fourteen months at the ground floor of 3-storied ferro-reinforced concrete building, it was removed to the prefabricated house near the old position of the monitor at January 1973. As a result of the removement of the monitor, the expected values for the counting rate and barometric coefficient of our neutron monitor were obtained, 7.5x10 4 cph and -0.64% mb respectively. The monitor was moved out into a new place, the statistical accuracy of counting rate is altered from 0.44% (hourly counting rate) to 0.36%. It can be considered that there is no effect of concrete building near the monitor, for reason that the zenith angle is opened more than 60 0 over the monitor. The difference between the new and the old measurement - measurement environments, intensities, barometric coefficient and others - were discussed. The continuous measurement of the cosmic ray neutron intensity at Fukushima will be kept on beaten track, and the obtained data of the cosmic ray neutron intensity (uncorrected, corrected intensity and barometric pressure) will be sent to WDC-C2 in form of monthly tables. (author)

  12. Measuring coding intensity in the Medicare Advantage program.

    Science.gov (United States)

    Kronick, Richard; Welch, W Pete

    2014-01-01

    In 2004, Medicare implemented a system of paying Medicare Advantage (MA) plans that gave them greater incentive than fee-for-service (FFS) providers to report diagnoses. Risk scores for all Medicare beneficiaries 2004-2013 and Medicare Current Beneficiary Survey (MCBS) data, 2006-2011. Change in average risk score for all enrollees and for stayers (beneficiaries who were in either FFS or MA for two consecutive years). Prevalence rates by Hierarchical Condition Category (HCC). Each year the average MA risk score increased faster than the average FFS score. Using the risk adjustment model in place in 2004, the average MA score as a ratio of the average FFS score would have increased from 90% in 2004 to 109% in 2013. Using the model partially implemented in 2014, the ratio would have increased from 88% to 102%. The increase in relative MA scores appears to largely reflect changes in diagnostic coding, not real increases in the morbidity of MA enrollees. In survey-based data for 2006-2011, the MA-FFS ratio of risk scores remained roughly constant at 96%. Intensity of coding varies widely by contract, with some contracts coding very similarly to FFS and others coding much more intensely than the MA average. Underpinning this relative growth in scores is particularly rapid relative growth in a subset of HCCs. Medicare has taken significant steps to mitigate the effects of coding intensity in MA, including implementing a 3.4% coding intensity adjustment in 2010 and revising the risk adjustment model in 2013 and 2014. Given the continuous relative increase in the average MA risk score, further policy changes will likely be necessary.

  13. Turbulence intensity measurement in the wind tunnel used for airfoil flutter investigation

    Directory of Open Access Journals (Sweden)

    Šidlof Petr

    2017-01-01

    Full Text Available The paper reports on hot wire turbulence intensity measurements performed in the entry of a suction-type wind tunnel, used for investigation of flow-induced vibration of airfoils and slender structures. The airfoil is elastically supported with two degrees of freedom (pitch and plunge in the test section of the wind tunnel with lateral optical access for interferometric measurements, and free to oscillate. The turbulence intensity was measured for velocities up to M = 0.3 i with the airfoil blocked, ii with the airfoil self-oscillating. Measurements were performed for a free inlet and further with two different turbulence grids generating increased turbulence intensity levels. For the free inlet and static airfoil, the turbulence intensity lies below 0.4%. The turbulence grids G1 and G2 increase the turbulence level up to 1.8% and 2.6%, respectively. When the airfoil is free to oscillate due to fluid-structure interaction, its motion disturbs the surrounding flow field and increases the measured turbulence intensity levels up to 5%.

  14. [FRC measurement in intensive care patients. A definition of standards].

    Science.gov (United States)

    Wauer, H J; Lorenz, B A; Kox, W J

    1998-10-01

    Determination of Functional Residual Capacity (FRC) can be performed through washout methods, indicator gas dilution or bodyplethysmography. Some of these techniques have been adapted for use in intensive care patients whilst being mechanically ventilated. However, most measurement setups are bulky, cumbersome to use and their running costs are high. Hence FRC measurement has not become a routine method in intensive care although it offers considerable advantages in the management of ventilated patients such as the determination of "best PEEP", the detection of progressive alveolar collapse in the course of acute lung injury and during weaning from mechanical ventilation. Up to now most efforts to improve and simplify FRC measurement were made at the expense of accuracy. An ideal method ought to be accurate, easy to handle and cost-effective. It should supply not only FRC data but also information about intrapulmonary gas distribution and dead space. These demands can be met using modern data acquisition software. The pros and cons of all methods available for FRC measurement are discussed in view of their suitability for intensive care patients. A conventional nitrogen washout using emission spectroscopy for measurement of nitrogen concentration gives satisfying exact values for the determination of the parameters mentioned above. The measurement error can be lowered under 5% by special corrections for flow and nitrogen signal (delay and rise times, changes of gas viscosity). For flow measurement a normal pneumotachograph can be used. Using a laptop computer for data acquisition the bed-side monitor fulfills most of the demands in intensive care. It is then also possible to measure indices of intrapulmonary gas distribution such as Alveolar Mixing Efficiency and Lung Clearance Index.

  15. Public attitudes toward nuclear power generation. Focusing on measurement of attitude intensity

    International Nuclear Information System (INIS)

    Nagai, Yasuko; Hayashi, Chikio

    1999-01-01

    The purpose of the present study was to 1) examine the differences of the perception between nuclear power generation (NPG) and electric power generation by nuclear fusion, 2) find the structural characteristics of the attitude toward NPG, 3) shed light on the characteristics of knowledge about NPG, and 4) develop a scale to measure the intensity in attitude toward NPG. Subjects (N = 1,582) were randomly assigned into 4 groups and were asked to answer a questionnaire including public attitudes toward NPG and related matters. The results were as follows: 1) the perception of electric power generation by nuclear fusion was less favorable than that of NPG; 2) Items which correlated with attitudes toward NPG were: 'sense of anxiety,' sensitivity to risk,' 'trust in science and technology,' 'evaluation of Japan's nuclear policy', 'evaluation of electric power companies,' and interest in life and environmental issues.' Moreover, people with a strong attitude tended to be rational and had a better knowledge of NPG; 3) The evaluation of the amount of subjective knowledge concerning nuclear power and electric power generation was reliable as a measure of objective knowledge; 4) The measurement method used in this study was characterized by the use of biased questions(ten positively and ten negatively biased questions) which were shown to the subjects using the split-half method. An attempt was made to measure the attitude and its intensity taking into consideration gender, positive or negative attitude toward NPG, level of knowledge about NPG, age, and occupation. As a result, differences in intensity between different attributes were found. (author)

  16. Adaptive projection intensity adjustment for avoiding saturation in three-dimensional shape measurement

    Science.gov (United States)

    Chen, Chao; Gao, Nan; Wang, Xiangjun; Zhang, Zonghua

    2018-03-01

    Phase-based fringe projection methods have been commonly used for three-dimensional (3D) measurements. However, image saturation results in incorrect intensities in captured fringe pattern images, leading to phase and measurement errors. Existing solutions are complex. This paper proposes an adaptive projection intensity adjustment method to avoid image saturation and maintain good fringe modulation in measuring objects with a high range of surface reflectivities. The adapted fringe patterns are created using only one prior step of fringe-pattern projection and image capture. First, a set of phase-shifted fringe patterns with maximum projection intensity value of 255 and a uniform gray level pattern are projected onto the surface of an object. The patterns are reflected from and deformed by the object surface and captured by a digital camera. The best projection intensities corresponding to each saturated-pixel clusters are determined by fitting a polynomial function to transform captured intensities to projected intensities. Subsequently, the adapted fringe patterns are constructed using the best projection intensities at projector pixel coordinate. Finally, the adapted fringe patterns are projected for phase recovery and 3D shape calculation. The experimental results demonstrate that the proposed method achieves high measurement accuracy even for objects with a high range of surface reflectivities.

  17. Photometric intensity and polarization measurements of the solar corona.

    Science.gov (United States)

    Mcdougal, D. S.

    1971-01-01

    Use of a satellite photometric observatory (SPO) to measure the solar corona from Miahuatlan, Mexico during the Mar. 7, 1970, total eclipse of the sun. The SPO is equipped with a 24-in. Cassegrainian telescope, a four-channel photoelectric photometer, a Wollaston prism, and a rotating half-wave plate. Simultaneous measurements were made of the two orthogonal components of coronal light in the B and R bands of the UBVRI system. A 1-minute arc aperture was scanned from the lunar disk center out to five solar radii in a series of spirals of gradually increasing radius. For the first time, simultaneous multicolor intensity, degree, and angle of polarization profiles are computed from photoelectric measurements. Comparison of the variations of the measurements for each spiral scan yield a detailed picture of the intensity and polarization features in the K corona.

  18. The summertime Boreal forest field measurement intensive (HUMPPA-COPEC-2010): an overview of meteorological and chemical influences

    NARCIS (Netherlands)

    Williams, J.; Crowley, J.; Fischer, H.; Harder, H.; Martinez, M.; Ouwersloot, H.G.; Vilà-Guerau de Arellano, J.; Ganzeveld, L.N.; Lelieveld, J.

    2011-01-01

    This paper describes the background, instrumentation, goals, and the regional influences on the HUMPPACOPEC intensive field measurement campaign, conducted at the Boreal forest research station SMEAR II (Station for Measuring Ecosystem-Atmosphere Relation) in Hyyti¨al¨a, Finland from 12 July–12

  19. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... for a breath. Absolute Intensity The amount of energy used by the body per minute of activity. ... or vigorous-intensity based upon the amount of energy used by the body while doing the activity. ...

  20. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Share Compartir For more help with what counts as aerobic activity, watch this video: Windows Media Player, ... The table below lists examples of activities classified as moderate-intensity or vigorous-intensity based upon the ...

  1. Optimal distribution of integration time for intensity measurements in Stokes polarimetry.

    Science.gov (United States)

    Li, Xiaobo; Liu, Tiegen; Huang, Bingjing; Song, Zhanjie; Hu, Haofeng

    2015-10-19

    We consider the typical Stokes polarimetry system, which performs four intensity measurements to estimate a Stokes vector. We show that if the total integration time of intensity measurements is fixed, the variance of the Stokes vector estimator depends on the distribution of the integration time at four intensity measurements. Therefore, by optimizing the distribution of integration time, the variance of the Stokes vector estimator can be decreased. In this paper, we obtain the closed-form solution of the optimal distribution of integration time by employing Lagrange multiplier method. According to the theoretical analysis and real-world experiment, it is shown that the total variance of the Stokes vector estimator can be significantly decreased about 40% in the case discussed in this paper. The method proposed in this paper can effectively decrease the measurement variance and thus statistically improves the measurement accuracy of the polarimetric system.

  2. Intensity autocorrelation measurements of frequency combs in the terahertz range

    Science.gov (United States)

    Benea-Chelmus, Ileana-Cristina; Rösch, Markus; Scalari, Giacomo; Beck, Mattias; Faist, Jérôme

    2017-09-01

    We report on direct measurements of the emission character of quantum cascade laser based frequency combs, using intensity autocorrelation. Our implementation is based on fast electro-optic sampling, with a detection spectral bandwidth matching the emission bandwidth of the comb laser, around 2.5 THz. We find the output of these frequency combs to be continuous even in the locked regime, but accompanied by a strong intensity modulation. Moreover, with our record temporal resolution of only few hundreds of femtoseconds, we can resolve correlated intensity modulation occurring on time scales as short as the gain recovery time, about 4 ps. By direct comparison with pulsed terahertz light originating from a photoconductive emitter, we demonstrate the peculiar emission pattern of these lasers. The measurement technique is self-referenced and ultrafast, and requires no reconstruction. It will be of significant importance in future measurements of ultrashort pulses from quantum cascade lasers.

  3. Measuring energy efficiency: Is energy intensity a good evidence base?

    International Nuclear Information System (INIS)

    Proskuryakova, L.; Kovalev, A.

    2015-01-01

    Highlights: • Energy intensity measure reflects consumption, not energy efficiency. • Thermodynamic indicators should describe energy efficiency at all levels. • These indicators should have no reference to economic or financial parameters. • A set of energy efficiency indicators should satisfy several basic principles. • There are trade-offs between energy efficiency, power and costs. - Abstract: There is a widespread assumption in energy statistics and econometrics that energy intensity and energy efficiency are equivalent measures of energy performance of economies. The paper points to the discrepancy between the engineering concept of energy efficiency and the energy intensity as it is understood in macroeconomic statistics. This double discrepancy concerns definitions (while engineering concept of energy efficiency is based on the thermodynamic definition, energy intensity includes economic measures) and use. With regard to the latter, the authors conclude that energy intensity can only provide indirect and delayed evidence of technological and engineering energy efficiency of energy conversion processes, which entails shortcomings for management and policymaking. Therefore, we suggest to stop considering subsectoral, sectoral and other levels of energy intensities as aggregates of lower-level energy efficiency. It is suggested that the insufficiency of energy intensity indicators can be compensated with the introduction of thermodynamic indicators describing energy efficiency at the physical, technological, enterprise, sub-sector, sectoral and national levels without references to any economic or financial parameters. Structured statistical data on thermodynamic efficiency is offered as a better option for identifying break-through technologies and technological bottle-necks that constrain efficiency advancements. It is also suggested that macro-level thermodynamic indicators should be based on the thermodynamic first law efficiency and the energy

  4. Cocaine-related admissions to an intensive care unit: a five-year study of incidence and outcomes.

    LENUS (Irish Health Repository)

    Galvin, S

    2010-02-01

    Cocaine misuse is increasing and it is evidently considered a relatively safe drug of abuse in Ireland. To address this perception, we reviewed the database of an 18-bed Dublin intensive care unit, covering all admissions from 2003 to 2007. We identified cocaine-related cases, measuring hospital mortality and long-term survival in early 2009. Cocaine-related admissions increased from around one annually in 2003-05 to 10 in 2007. Their median (IQR [range]) age was 25 (21-35 [17-47]) years and 78% were male. The median (IQR [range]) APACHE II score was 16 (11-27 [5-36]) and length of intensive care stay was 5 (3-9 [1-16]) days. Ten patients died during their hospital stay. A further five had died by the time of follow-up, a median of 24 months later. One was untraceable. Cocaine toxicity necessitating intensive care is increasingly common in Dublin. Hospital mortality in this series was 52%. These findings may help to inform public attitudes to cocaine.

  5. Using grey intensity adjustment strategy to enhance the measurement accuracy of digital image correlation considering the effect of intensity saturation

    Science.gov (United States)

    Li, Bang-Jian; Wang, Quan-Bao; Duan, Deng-Ping; Chen, Ji-An

    2018-05-01

    Intensity saturation can cause decorrelation phenomenon and decrease the measurement accuracy in digital image correlation (DIC). In the paper, the grey intensity adjustment strategy is proposed to improve the measurement accuracy of DIC considering the effect of intensity saturation. First, the grey intensity adjustment strategy is described in detail, which can recover the truncated grey intensities of the saturated pixels and reduce the decorrelation phenomenon. The simulated speckle patterns are then employed to demonstrate the efficacy of the proposed strategy, which indicates that the displacement accuracy can be improved by about 40% by the proposed strategy. Finally, the true experimental image is used to show the feasibility of the proposed strategy, which indicates that the displacement accuracy can be increased by about 10% by the proposed strategy.

  6. Electron temperature measurement by a helium line intensity ratio method in helicon plasmas

    International Nuclear Information System (INIS)

    Boivin, R.F.; Kline, J.L.; Scime, E.E.

    2001-01-01

    Electron temperature measurements in helicon plasmas are difficult. The presence of intense rf fields in the plasma complicates the interpretation of Langmuir probe measurements. Furthermore, the non-negligible ion temperature in the plasma considerably shortens the lifetime of conventional Langmuir probes. A spectroscopic technique based on the relative intensities of neutral helium lines is used to measure the electron temperature in the HELIX (Hot hELicon eXperiment) plasma [P. A. Keiter et al., Phys. Plasmas 4, 2741 (1997)]. This nonintrusive diagnostic is based on the fact that electron impact excitation rate coefficients for helium singlet and triplet states differ as a function of the electron temperature. The different aspects related to the validity of this technique to measure the electron temperature in rf generated plasmas are discussed in this paper. At low plasma density (n e ≤10 11 cm -3 ), this diagnostic is believed to be very reliable since the population of the emitting level can be easily estimated with reasonable accuracy by assuming that all excitation originates from the ground state (steady-state corona model). At higher density, secondary processes (excitation transfer, excitation from metastable, cascading) become more important and a more complex collisional radiative model must be used to predict the electron temperature. In this work, different helium transitions are examined and a suitable transition pair is identified. For an electron temperature of 10 eV, the line ratio is measured as a function of plasma density and compared to values predicted by models. The measured line ratio function is in good agreement with theory and the data suggest that the excitation transfer is the dominant secondary process in high-density plasmas

  7. Quantitative stress measurement of elastic deformation using mechanoluminescent sensor: An intensity ratio model

    Science.gov (United States)

    Cai, Tao; Guo, Songtao; Li, Yongzeng; Peng, Di; Zhao, Xiaofeng; Liu, Yingzheng

    2018-04-01

    The mechanoluminescent (ML) sensor is a newly developed non-invasive technique for stress/strain measurement. However, its application has been mostly restricted to qualitative measurement due to the lack of a well-defined relationship between ML intensity and stress. To achieve accurate stress measurement, an intensity ratio model was proposed in this study to establish a quantitative relationship between the stress condition and its ML intensity in elastic deformation. To verify the proposed model, experiments were carried out on a ML measurement system using resin samples mixed with the sensor material SrAl2O4:Eu2+, Dy3+. The ML intensity ratio was found to be dependent on the applied stress and strain rate, and the relationship acquired from the experimental results agreed well with the proposed model. The current study provided a physical explanation for the relationship between ML intensity and its stress condition. The proposed model was applicable in various SrAl2O4:Eu2+, Dy3+-based ML measurement in elastic deformation, and could provide a useful reference for quantitative stress measurement using the ML sensor in general.

  8. Tune measurements with high intensity ion beams at GSI SIS-18

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Rahul [GSI, Darmstadt (Germany); TEMF, TU Darmstadt (Germany); Forck, Peter; Kowina, Piotr; Kaufmann, Wolfgang [GSI, Darmstadt (Germany); Weiland, Thomas [TEMF, TU Darmstadt (Germany)

    2012-07-01

    A precise tune measurement during a full accelerating cycle is required to achieve stable high current operation. A new system has been commissioned at GSI for position, orbit and tune measurements. It consists of three distinct parts; an exciter which provides power to excite coherent betatron oscillations in the bunched beam; Fast ADCs to digitize the BPM signals at 125 MSa/s; the post processing electronics uses digitized BPM signals to acquire one position value per bunch. Subsequently the baseband tune is determined by Fourier transformation of the position data. Experiments were conducted to understand the effects of high beam intensity on tune at injection plateau (11.4 MeV/u) and during acceleration ramp (11.4-600 MeV/u). These experiments were performed with U{sup 73+} and Ar{sup 18+} ion beam at highest achievable intensities of 2.10{sup 9} and 2.5.10{sup 10} respectively. Tune shift with increased intensity was observed. The working principle of the tune measurement system and observed high intensity effects on tune will be reported in this contribution.

  9. Stressors in the relatives of patients admitted to an intensive care unit.

    Science.gov (United States)

    Barth, Angélica Adam; Weigel, Bruna Dorfey; Dummer, Claus Dieter; Machado, Kelly Campara; Tisott, Taís Montagner

    2016-09-01

    To identify and stratify the main stressors for the relatives of patients admitted to the adult intensive care unit of a teaching hospital. Cross-sectional descriptive study conducted with relatives of patients admitted to an intensive care unit from April to October 2014. The following materials were used: a questionnaire containing identification information and demographic data of the relatives, clinical data of the patients, and 25 stressors adapted from the Intensive Care Unit Environmental Stressor Scale. The degree of stress caused by each factor was determined on a scale of values from 1 to 4. The stressors were ranked based on the average score obtained. The main cause of admission to the intensive care unit was clinical in 36 (52.2%) cases. The main stressors were the patient being in a state of coma (3.15 ± 1.23), the patient being unable to speak (3.15 ± 1.20), and the reason for admission (3.00 ± 1.27). After removing the 27 (39.1%) coma patients from the analysis, the main stressors for the relatives were the reason for admission (2.75 ± 1.354), seeing the patient in the intensive care unit (2.51 ± 1.227), and the patient being unable to speak (2.50 ± 1.269). Difficulties in communication and in the relationship with the patient admitted to the intensive care unit were identified as the main stressors by their relatives, with the state of coma being predominant. By contrast, the environment, work routines, and relationship between the relatives and intensive care unit team had the least impact as stressors.

  10. About Solar Radiation Intensity Measurements and Data Processing

    Directory of Open Access Journals (Sweden)

    MICH-VANCEA Claudiu

    2012-10-01

    Full Text Available Measuring the intensity of solar radiation is one of the directions of investigation necessary for the implementation of photovoltaic systems in a particular geographical area. This can be done by using specific measuring equipment (pyranometer sensors based onthermal or photovoltaic principle. In this paper it is presented a method for measuring solar radiation (which has two main components - direct radiation and diffuse radiation with sensors based on photovoltaic principle. Such data are processed for positioning solarpanels, in order their efficiency to be maximized.

  11. A comparison of two different sound intensity measurement principles

    DEFF Research Database (Denmark)

    Jacobsen, Finn; de Bree, Hans-Elias

    2005-01-01

    , and compares the two measurement principles with particular regard to the sources of error in sound power determination. It is shown that the phase calibration of intensity probes that combine different transducers is very critical below 500 Hz if the measurement surface is very close to the source under test...

  12. Estimation of signal intensity for online measurement X-ray pinhole camera

    International Nuclear Information System (INIS)

    Dong Jianjun; Liu Shenye; Yang Guohong; Yu Yanning

    2009-01-01

    The signal intensity was estimated for on-line measurement X-ray pinhole camera with CCD as measurement equipment. The X-ray signal intensity counts after the attenuation of thickness-varied Be filters and different material flat mirrors respectively were estimated using the energy spectrum of certain laser prototype and the quantum efficiency curve of PI-SX1300 CCD camera. The calculated results indicate that Be filters no thicker than 200 μm can only reduce signal intensity by one order of magnitude, and so can Au flat mirror with 3 degree incident angle, Ni, C and Si flat mirrors with 5 degree incident angle,but the signal intensity counts for both attenuation methods are beyond the saturation counts of the CCD camera. We also calculated the attenuation of signal intensity for different thickness Be filters combined with flat mirrors, indicates that the combination of Be filters with the thickness between 20 and 40 μm and Au flat mirror with 3 degree incident angle or Ni flat mirror with 5 degree incident angle is a good choice for the attenuation of signal intensity. (authors)

  13. Competitive state anxiety and self-confidence: intensity and direction as relative predictors of performance on a golf putting task.

    Science.gov (United States)

    Chamberlain, Sean T; Hale, Bruce D

    2007-06-01

    This study considered relationships between the intensity and directional aspects of competitive state anxiety as measured by the modified Competitive Sport Anxiety Inventory-2(D) (Jones & Swain, 1992) in a sample of 12 experienced male golfers. Anxiety and performance scores from identical putting tasks performed under three different anxiety-manipulated competitive conditions were used to assess both the predictions of Multidimensional Anxiety Theory (MAT; Martens et al., 1990) and the relative value of intensity and direction in explaining performance variance. A within-subjects regression analysis of the intra-individual data showed partial support for the three MAT hypotheses. Cognitive anxiety intensity demonstrated a negative linear relationship with performance, somatic anxiety intensity showed a curvilinear relationship with performance, and self-confidence intensity revealed a positive linear relation. Cognitive directional anxiety illustrated a positive linear relationship with putting performance. Multiple regression analyses indicated that direction (42% of variance) was a better predictor of performance than intensity (22%).

  14. Coupling of relative intensity noise and pathlength noise to the length measurement in the optical metrology system of LISA Pathfinder

    Science.gov (United States)

    Wittchen, Andreas; the LPF Collaboration

    2017-05-01

    LISA Pathfinder is a technology demonstration mission for the space-based gravitational wave observatory, LISA. It demonstrated that the performance requirements for the interferometric measurement of two test masses in free fall can be met. An important part of the data analysis is to identify the limiting noise sources. [1] This measurement is performed with heterodyne interferometry. The performance of this optical metrology system (OMS) at high frequencies is limited by sensing noise. One such noise source is Relative Intensity Noise (RIN). RIN is a property of the laser, and the photodiode current generated by the interferometer signal contains frequency dependant RIN. From this electric signal the phasemeter calculates the phase change and laser power, and the coupling of RIN into the measurement signal depends on the noise frequency. RIN at DC, at the heterodyne frequency and at two times the heterodyne frequency couples into the phase. Another important noise at high frequencies is path length noise. To reduce the impact this noise is suppressed with a control loop. Path length noise not suppressed will couple directly into the length measurement. The subtraction techniques of both noise sources depend on the phase difference between the reference signal and the measurement signal, and thus on the test mass position. During normal operations we position the test mass at the interferometric zero, which is optimal for noise subtraction purposes. This paper will show results from an in-flight experiment where the test mass position was changed to make the position dependant noise visible.

  15. Measurement of high-power microwave pulse under intense ...

    Indian Academy of Sciences (India)

    Abstract. KALI-1000 pulse power system has been used to generate single pulse nanosecond duration high-power microwaves (HPM) from a virtual cathode oscillator. (VIRCATOR) device. HPM power measurements were carried out using a transmitting– receiving system in the presence of intense high frequency (a few ...

  16. Accounting for adaptation and intensity in projecting heat wave-related mortality.

    Science.gov (United States)

    Wang, Yan; Nordio, Francesco; Nairn, John; Zanobetti, Antonella; Schwartz, Joel D

    2018-02-01

    How adaptation and intensity of heat waves affect heat wave-related mortality is unclear, making health projections difficult. We estimated the effect of heat waves, the effect of the intensity of heat waves, and adaptation on mortality in 209 U.S. cities with 168 million people during 1962-2006. We improved the standard time-series models by incorporating the intensity of heat waves using excess heat factor (EHF) and estimating adaptation empirically using interactions with yearly mean summer temperature (MST). We combined the epidemiological estimates for heat wave, intensity, and adaptation with the Coupled Model Intercomparison Project Phase 5 (CMIP5) multi-model dataset to project heat wave-related mortality by 2050. The effect of heat waves increased with its intensity. Adaptation to heat waves occurred, which was shown by the decreasing effect of heat waves with MST. However, adaptation was lessened as MST increased. Ignoring adaptation in projections would result in a substantial overestimate of the projected heat wave-related mortality (by 277-747% in 2050). Incorporating the empirically estimated adaptation into projections would result in little change in the projected heat wave-related mortality between 2006 and 2050. This differs regionally, however, with increasing mortality over time for cities in the southern and western U.S. but decreasing mortality over time for the north. Accounting for adaptation is important to reduce bias in the projections of heat wave-related mortality. The finding that the southern and western U.S. are the areas that face increasing heat-related deaths is novel, and indicates that more regional adaptation strategies are needed. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Relative Match Intensities at High Altitude in Highly-Trained Young Soccer Players (ISA3600).

    Science.gov (United States)

    Buchheit, Martin; Hammond, Kristal; Bourdon, Pitre C; Simpson, Ben M; Garvican-Lewis, Laura A; Schmidt, Walter F; Gore, Christopher J; Aughey, Robert J

    2015-03-01

    To compare relative match intensities of sea-level versus high-altitude native soccer players during a 2-week camp at 3600 m, data from 7 sea-level (Australian U17 National team, AUS) and 6 high-altitude (a Bolivian U18 team, BOL) native soccer players were analysed. Two matches were played at sea-level and three at 3600 m on Days 1, 6 and 13. The Yo-Yo Intermittent recovery test (vYo-YoIR1) was performed at sea-level, and on Days 3 and 10. Match activity profiles were measured via 10-Hz GPS. Distance covered >14.4 km.h(-1) (D>14.4 km·h(-1)) and >80% of vYo-YoIR1 (D>80%vYo-YoIR1) were examined. Upon arrival at altitude, there was a greater decrement in vYo-YoIR1 (Cohen's d +1.0, 90%CL ± 0.8) and D>14.4 km·h(-1) (+0.5 ± 0.8) in AUS. D>14.4 km.h(-1) was similarly reduced relative to vYo-YoIR1 in both groups, so that D>80%vYo-YoIR1 remained similarly unchanged (-0.1 ± 0.8). Throughout the altitude sojourn, vYo-YoIR1 and D>14.4 km·h(-1) increased in parallel in AUS, so that D>80%vYo-YoIR1 remained stable in AUS (+6.0%/match, 90%CL ± 6.7); conversely D>80%vYo-YoIR1 decreased largely in BOL (-12.2%/match ± 6.2). In sea-level natives competing at high-altitude, changes in match running performance likely follow those in high-intensity running performance. Bolivian data confirm that increases in 'fitness' do not necessarily translate into greater match running performance, but rather in reduced relative exercise intensity. Key pointsWhen playing at high-altitude, players may alter their activities during matches in relation to their transient maximal physical capacities, possibly to maintain a 'tolerable' relative exercise intensity.While there is no doubt that running performance per se in not the main determinant of match outcomes (Carling, 2013), fitness levels influence relative match intensity (Buchheit et al., 2012, Mendez-Villanueva et al., 2013), which in-turn may impact on decision making and skill performance (Rampinini et al., 2008).In the context of

  18. Measurement-device-independent quantum key distribution with correlated source-light-intensity errors

    Science.gov (United States)

    Jiang, Cong; Yu, Zong-Wen; Wang, Xiang-Bin

    2018-04-01

    We present an analysis for measurement-device-independent quantum key distribution with correlated source-light-intensity errors. Numerical results show that the results here can greatly improve the key rate especially with large intensity fluctuations and channel attenuation compared with prior results if the intensity fluctuations of different sources are correlated.

  19. Intensity-Curvature Measurement Approaches for the Diagnosis of Magnetic Resonance Imaging Brain Tumors

    Directory of Open Access Journals (Sweden)

    Carlo Ciulla

    2015-11-01

    Full Text Available This research presents signal-image post-processing techniques called Intensity-Curvature Measurement Approaches with application to the diagnosis of human brain tumors detected through Magnetic Resonance Imaging (MRI. Post-processing of the MRI of the human brain encompasses the following model functions: (i bivariate cubic polynomial, (ii bivariate cubic Lagrange polynomial, (iii monovariate sinc, and (iv bivariate linear. The following Intensity-Curvature Measurement Approaches were used: (i classic-curvature, (ii signal resilient to interpolation, (iii intensity-curvature measure and (iv intensity-curvature functional. The results revealed that the classic-curvature, the signal resilient to interpolation and the intensity-curvature functional are able to add additional information useful to the diagnosis carried out with MRI. The contribution to the MRI diagnosis of our study are: (i the enhanced gray level scale of the tumor mass and the well-behaved representation of the tumor provided through the signal resilient to interpolation, and (ii the visually perceptible third dimension perpendicular to the image plane provided through the classic-curvature and the intensity-curvature functional.

  20. Energy intensity ratios as net energy measures of United States energy production and expenditures

    International Nuclear Information System (INIS)

    King, C W

    2010-01-01

    In this letter I compare two measures of energy quality, energy return on energy invested (EROI) and energy intensity ratio (EIR) for the fossil fuel consumption and production of the United States. All other characteristics being equal, a fuel or energy system with a higher EROI or EIR is of better quality because more energy is provided to society. I define and calculate the EIR for oil, natural gas, coal, and electricity as measures of the energy intensity (units of energy divided by money) of the energy resource relative to the energy intensity of the overall economy. EIR measures based upon various unit prices for energy (e.g. $/Btu of a barrel of oil) as well as total expenditures on energy supplies (e.g. total dollars spent on petroleum) indicate net energy at different points in the supply chain of the overall energy system. The results indicate that EIR is an easily calculated and effective proxy for EROI for US oil, gas, coal, and electricity. The EIR correlates well with previous EROI calculations, but adds additional information on energy resource quality within the supply chain. Furthermore, the EIR and EROI of oil and gas as well as coal were all in decline for two time periods within the last 40 years, and both time periods preceded economic recessions.

  1. Non-perturbative measurement of low-intensity charged particle beams

    Science.gov (United States)

    Fernandes, M.; Geithner, R.; Golm, J.; Neubert, R.; Schwickert, M.; Stöhlker, T.; Tan, J.; Welsch, C. P.

    2017-01-01

    Non-perturbative measurements of low-intensity charged particle beams are particularly challenging to beam diagnostics due to the low amplitude of the induced electromagnetic fields. In the low-energy antiproton decelerator (AD) and the future extra low energy antiproton rings at CERN, an absolute measurement of the beam intensity is essential to monitor the operation efficiency. Superconducting quantum interference device (SQUID) based cryogenic current comparators (CCC) have been used for measuring slow charged beams in the nA range, showing a very good current resolution. But these were unable to measure fast bunched beams, due to the slew-rate limitation of SQUID devices and presented a strong susceptibility to external perturbations. Here, we present a CCC system developed for the AD machine, which was optimised in terms of its current resolution, system stability, ability to cope with short bunched beams, and immunity to mechanical vibrations. This paper presents the monitor design and the first results from measurements with a low energy antiproton beam obtained in the AD in 2015. These are the first CCC beam current measurements ever performed in a synchrotron machine with both coasting and short bunched beams. It is shown that the system is able to stably measure the AD beam throughout the entire cycle, with a current resolution of 30 {nA}.

  2. Hydroxyl temperature and intensity measurements during noctilucent cloud displays

    Directory of Open Access Journals (Sweden)

    M. J. Taylor

    1995-10-01

    Full Text Available Two Fourier transform spectrometers have been used to investigate the properties of the near-infrared hydroxyl (OH nightglow emission under high-latitude summertime conditions and any association with noctilucent clouds (NLCs. The measurements were made from Poker Flat Research Range, Alaska (65.1°N, 147.5°W, during August 1986. Simultaneous photographic observations of the northern twilight sky were made from Gulkana, Alaska (62.2°N, 145.5°W, approximately 340 km to the south to establish the presence of NLCs over the spectrometer site. Data exhibiting significant short-term variations in the relative intensity (as much as 50–100% and rotational temperature (typically 5–15 K were recorded on six occasions when NLCs were observed. Joint measurements were also obtained on several "cloud-free" nights. No obvious relationship was found linking the mean OH intensity or its variation with the occurrence of NLCs. However, a clear tendency was found for the mean OH temperature to be lower on NLC nights than on cloud-free nights. In particular, a significant fraction of the OH(3–1 band spectra recorded by each instrument (16–57% exhibited temperatures below ~154 K on NLC nights compared with <3% on cloud-free nights. This result is qualitatively consistent with current models for ice particle nucleation and growth, but the mean OH temperature on NLC nights (~156 K was significantly higher than would be expected for long-term particle growth in this region. These observations raise questions concerning the expected proximity of the high-latitude, summertime OH layer and the NLC growth region.

  3. Hydroxyl temperature and intensity measurements during noctilucent cloud displays

    Directory of Open Access Journals (Sweden)

    M. J. Taylor

    Full Text Available Two Fourier transform spectrometers have been used to investigate the properties of the near-infrared hydroxyl (OH nightglow emission under high-latitude summertime conditions and any association with noctilucent clouds (NLCs. The measurements were made from Poker Flat Research Range, Alaska (65.1°N, 147.5°W, during August 1986. Simultaneous photographic observations of the northern twilight sky were made from Gulkana, Alaska (62.2°N, 145.5°W, approximately 340 km to the south to establish the presence of NLCs over the spectrometer site. Data exhibiting significant short-term variations in the relative intensity (as much as 50–100% and rotational temperature (typically 5–15 K were recorded on six occasions when NLCs were observed. Joint measurements were also obtained on several "cloud-free" nights. No obvious relationship was found linking the mean OH intensity or its variation with the occurrence of NLCs. However, a clear tendency was found for the mean OH temperature to be lower on NLC nights than on cloud-free nights. In particular, a significant fraction of the OH(3–1 band spectra recorded by each instrument (16–57% exhibited temperatures below ~154 K on NLC nights compared with <3% on cloud-free nights. This result is qualitatively consistent with current models for ice particle nucleation and growth, but the mean OH temperature on NLC nights (~156 K was significantly higher than would be expected for long-term particle growth in this region. These observations raise questions concerning the expected proximity of the high-latitude, summertime OH layer and the NLC growth region.

  4. [Spanish translation and validation of the EMPATHIC-30 questionnaire to measure parental satisfaction in intensive care units].

    Science.gov (United States)

    Pilar Orive, Francisco Javier; Basabe Lozano, Jasone; López Zuñiga, Aurora; López Fernández, Yolanda M; Escudero Argaluza, Julene; Latour, Jos M

    2017-11-03

    Few validated surveys measuring parental satisfaction in the Paediatric Intensive Care Unit (PICU) are available, and none of them in Spanish language. The aim of this study is to translate and validate the questionnaire EMpowerment of PArents in THe Intensive Care (EMPATHIC). This questionnaire measures parental perceptions of paediatric intensive care-related satisfaction items in the Spanish language. A prospective cohort study was carried out using questionnaires completed by relatives of children (range 0-17 years old) admitted into a tertiary PICU. Inclusion criteria were a length of stay more than 24h, and a suitable understanding of Spanish language by parents or guardians. Exclusion criteria were re-admissions and deceased patients. The questionnaire was translated from English to Spanish language using a standardised procedure, after which it was used in a cross-sectional observational study was performed to confirm its validity and consistency. Reliability was estimated using Cronbach's α, and content validity using Spearman's correlation analysis. A total of 150 questionnaires were collected. A Cronbach's α was obtained for domains greater than 0.7, showing a high internal consistency from the questionnaire. Validity was measured by correlating 5 domains with 4 general satisfaction items, documenting an adequate correlation (Rs: 0.41-0.66, P<.05). The Spanish version of EMPHATIC 30 is a feasible, easy, and suitable tool in this specific environment, based on the results. EMPATHIC 30 is able to measure parental satisfaction, and may serve as a valid indicator to measure quality of care in Spanish PICUs. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  5. Disentangling the relative importance of changes in climate and land-use intensity in driving recent bird population trends.

    Directory of Open Access Journals (Sweden)

    Sarah M Eglington

    Full Text Available Threats to biodiversity resulting from habitat destruction and deterioration have been documented for many species, whilst climate change is regarded as increasingly impacting upon species' distribution and abundance. However, few studies have disentangled the relative importance of these two drivers in causing recent population declines. We quantify the relative importance of both processes by modelling annual variation in population growth of 18 farmland bird species in the UK as a function of measures of land-use intensity and weather. Modelled together, both had similar explanatory power in accounting for annual fluctuations in population growth. When these models were used to retrodict population trends for each species as a function of annual variation in land-use intensity and weather combined, and separately, retrodictions incorporating land-use intensity were more closely linked to observed population trends than retrodictions based only on weather, and closely matched the UK farmland bird index from 1970 onwards. Despite more stable land-use intensity in recent years, climate change (inferred from weather trends has not overtaken land-use intensity as the dominant driver of bird populations.

  6. Absolute intensity calibration for ECE measurements on EAST

    International Nuclear Information System (INIS)

    Liu Yong; Liu Xiang; Zhao Hailin

    2014-01-01

    In this proceeding, the results of the in-situ absolute intensity calibration for ECE measurements on EAST are presented. A 32-channel heterodyne radiometer system and a Michelson interferometer on EAST have been calibrated independently, and preliminary results from plasma operation indicate a good agreement between the electron temperature profiles obtained with different systems. (author)

  7. Schistosome infection intensity is inversely related to auto-reactive antibody levels.

    Directory of Open Access Journals (Sweden)

    Francisca Mutapi

    2011-05-01

    Full Text Available In animal experimental models, parasitic helminth infections can protect the host from auto-immune diseases. We conducted a population-scale human study investigating the relationship between helminth parasitism and auto-reactive antibodies and the subsequent effect of anti-helminthic treatment on this relationship. Levels of antinuclear antibodies (ANA and plasma IL-10 were measured by enzyme linked immunosorbent assay in 613 Zimbabweans (aged 2-86 years naturally exposed to the blood fluke Schistosoma haematobium. ANA levels were related to schistosome infection intensity and systemic IL-10 levels. All participants were offered treatment with the anti-helminthic drug praziquantel and 102 treated schoolchildren (5-16 years were followed up 6 months post-antihelminthic treatment. ANA levels were inversely associated with current infection intensity but were independent of host age, sex and HIV status. Furthermore, after allowing for the confounding effects of schistosome infection intensity, ANA levels were inversely associated with systemic levels of IL-10. ANA levels increased significantly 6 months after anti-helminthic treatment. Our study shows that ANA levels are attenuated in helminth-infected humans and that anti-helminthic treatment of helminth-infected people can significantly increase ANA levels. The implications of these findings are relevant for understanding both the aetiology of immune disorders mediated by auto-reactive antibodies and in predicting the long-term consequences of large-scale schistosomiasis control programs.

  8. Validation of a 10-item care-related regret intensity scale (RIS-10) for health care professionals.

    Science.gov (United States)

    Courvoisier, Delphine S; Cullati, Stéphane; Haller, Chiara S; Schmidt, Ralph E; Haller, Guy; Agoritsas, Thomas; Perneger, Thomas V

    2013-03-01

    Regret after one of the many decisions and interventions that health care professionals make every day can have an impact on their own health and quality of life, and on their patient care practices. To validate a new care-related regret intensity scale (RIS) for health care professionals. Retrospective cross-sectional cohort study with a 1-month follow-up (test-retest) in a French-speaking University Hospital. A total of 469 nurses and physicians responded to the survey, and 175 answered the retest. RIS, self-report questions on the context of the regret-inducing event, its consequences for the patient, involvement of the health care professionals, and changes in patient care practices after the event. We measured the impact of regret intensity on health care professionals with the satisfaction with life scale, the SF-36 first question (self-reported health), and a question on self-esteem. On the basis of factor analysis and item response analysis, the initial 19-item scale was shortened to 10 items. The resulting scale (RIS-10) was unidimensional and had high internal consistency (α=0.87) and acceptable test-retest reliability (0.70). Higher regret intensity was associated with (a) more consequences for the patient; (b) lower life satisfaction and poorer self-reported health in health care professionals; and (c) changes in patient care practices. Nurses reported analyzing the event and apologizing, whereas physicians reported talking preferentially to colleagues, rather than to their supervisor, about changing practices. The RIS is a valid and reliable measure of care-related regret intensity for hospital-based physicians and nurses.

  9. The intensity-pitch relation revisited: monopolar versus bipolar cochlear stimulation.

    Science.gov (United States)

    Arnoldner, Christoph; Riss, Dominik; Kaider, Alexandra; Mair, Alois; Wagenblast, Jens; Baumgartner, Wolf-Dieter; Gstöttner, Wolfgang; Hamzavi, Jafar-Sasan

    2008-09-01

    The very high speech perception scores now being achieved with cochlear implants have led to demands for similar levels of achievement in music perception and perception in noisy environments. One of the crucial factors in these fields is pitch perception. The aim of the present study was to investigate the extent to which pitch perception is influenced by the intensity of the stimulus, through the use of different stimulation modes (monopolar, bipolar) and different electrodes (lateral and perimodiolar). Sixteen postlingually deafened patients with an average implant use of 3.1 years were included in this study. All patients were using a Cochlear (CI24M, CI24R, CI24RE) cochlear implant. Subjects were asked to compare the pitch of an intensity-constant reference tone with the pitch of a test tone of varying intensity. The test was repeated for apical, mediocochlear, and basal channel locations, and also for monopolar and bipolar stimulation. It was found that in monopolar stimulation 87.5% and in bipolar stimulation 85.7% of the patients perceived a clear pitch change with changing intensity of the stimulus (Spearman correlation coefficients r 0.3, respectively). A total of 73.1% of these patients perceived lower pitches with increasing intensity, 26.9% reported the opposite effect. No statistically significant difference in the intensity-pitch correlation could be found between mono- and bipolar stimulation. Neither the mean dynamic range nor the type of electrode used was found to be related to the correlation coefficient. Although the majority of today's cochlear implant recipients perform well and the intensity-pitch relation in cochlear implant recipients is still poorly understood, rising demands on speech-coding strategies may soon make a compensation of the pitch shifts desirable. Although the results of our study tend to argue against a peripheral mechanism, the exact origin of this phenomenon remains unclear.

  10. Lucid Dreaming: Intensity, But Not Frequency, Is Inversely Related to Psychopathology

    Directory of Open Access Journals (Sweden)

    Liat Aviram

    2018-03-01

    Full Text Available Lucid dreaming (LD is awareness that one is dreaming, during the dream state. However, some define and assess LD relying also on controlling dream events, although control is present only in a subset of lucid dreams. LD has been claimed to represent well-being, and has even been used as a therapeutic agent. Conversely, LD is associated with mixed sleep-wake states, which are related to bizarre cognitions, stress, and psychopathology, and have been construed as arousal permeating and disrupting sleep. We propose that previous conflicting findings regarding relations between LD and both psychopathology and well-being, stem from the non-differentiated assessment of frequency and control. The present study aimed to develop an expansive measure of several LD characteristics (the Frequency and Intensity Lucid Dream questionnaire; FILD, and explore their relations with symptomatology. Undergraduate students (N = 187 self-reported trait LD, psychopathology (depression, anxiety, obsessive-compulsive symptoms, dissociation, and schizotypy, stress, and sleep problems; 2 months later, a subsample (n = 78 reported psychopathology again, and also completed a dream diary each morning for 14 days. Preliminary evidence supports the reliability and validity of the FILD. Items converged into four domains: frequency, intensity (e.g., control, activity, certainty of dreaming, emotional valence, and the use of induction techniques. We report an optimal frequency cutoff score to identify those likely to experience LD within a 2-week period. Whereas LD frequency was unrelated to psychopathology, LD intensity, and positive LD emotions, were inversely associated with several psychopathological symptoms. Use of deliberate induction techniques was positively associated with psychopathology and sleep problems. Additionally, we demonstrated directionality by employing a prospective-longitudinal design, showing that deliberate LD induction predicted an increase in

  11. Lucid Dreaming: Intensity, But Not Frequency, Is Inversely Related to Psychopathology

    Science.gov (United States)

    Aviram, Liat; Soffer-Dudek, Nirit

    2018-01-01

    Lucid dreaming (LD) is awareness that one is dreaming, during the dream state. However, some define and assess LD relying also on controlling dream events, although control is present only in a subset of lucid dreams. LD has been claimed to represent well-being, and has even been used as a therapeutic agent. Conversely, LD is associated with mixed sleep-wake states, which are related to bizarre cognitions, stress, and psychopathology, and have been construed as arousal permeating and disrupting sleep. We propose that previous conflicting findings regarding relations between LD and both psychopathology and well-being, stem from the non-differentiated assessment of frequency and control. The present study aimed to develop an expansive measure of several LD characteristics (the Frequency and Intensity Lucid Dream questionnaire; FILD), and explore their relations with symptomatology. Undergraduate students (N = 187) self-reported trait LD, psychopathology (depression, anxiety, obsessive-compulsive symptoms, dissociation, and schizotypy), stress, and sleep problems; 2 months later, a subsample (n = 78) reported psychopathology again, and also completed a dream diary each morning for 14 days. Preliminary evidence supports the reliability and validity of the FILD. Items converged into four domains: frequency, intensity (e.g., control, activity, certainty of dreaming), emotional valence, and the use of induction techniques. We report an optimal frequency cutoff score to identify those likely to experience LD within a 2-week period. Whereas LD frequency was unrelated to psychopathology, LD intensity, and positive LD emotions, were inversely associated with several psychopathological symptoms. Use of deliberate induction techniques was positively associated with psychopathology and sleep problems. Additionally, we demonstrated directionality by employing a prospective-longitudinal design, showing that deliberate LD induction predicted an increase in dissociation and

  12. High-Resolution Energy and Intensity Measurements with CVD Diamond at REX-ISOLDE

    CERN Document Server

    Griesmayer, E; Dobos, D; Wenander, F; Bergoz, J; Bayle, H; Frais-Kölbl, H; Leinweber, J; Aumeyr, T; CERN. Geneva. BE Department

    2009-01-01

    A novel beam instrumentation device for the HIE-REX (High In-tensity and Energy REX) upgrade has been developed and tested at the On-Line Isotope Mass Separator ISOLDE, located at the European Laboratory for Particle Physics (CERN). This device is based on CVD diamond detector technology and is used for measuring the beam intensity, particle counting and measuring the energy spectrum of the beam. An energy resolution of 0.6% was measured at a carbon ion energy of 22.8 MeV. This corresponds to an energy spread of ± 140 keV.

  13. Comparison between the measurements of Radon Gas Concentrations and γ-ray intensities in Exploring the Black Sands at El-Burullus Beach

    International Nuclear Information System (INIS)

    Abdel-Razek, Y.A; Bakhit, A.F

    2009-01-01

    Ten well-located monitoring stations along El-Burullus beach were chosen to measure radon gas concentrations in the beach sands below surface, and γ-ray intensities at 10 cm above the surface. These stations were chosen to represent apparent concentrations of the black sands. Sand samples were collected from the different stations and analyzed to study the relation between the concentrations of the heavy minerals and the measured radon concentrations or the measured γ-ray intensities at these stations. It was found that radon gas concentrations measured at 6:00 Pm were about 2.82 times those measured at 1 :00 Pm due to diurnal variation of temperature. Measurements of radon gas concentrations inside the beach sands are found to be more reliable in qualitative exploration of black sands than the measurements of γ-ray intensities above the shore sands due to the random arrangement of the layers of these sands below surface

  14. Intensity related changes of running economy in recreational level distance runners.

    Science.gov (United States)

    Engeroff, Tobias; Bernardi, Andreas; Niederer, Daniel; Wilke, Jan; Vogt, Lutz; Banzer, Winfried

    2017-09-01

    Running economy (RE) is often described as a key demand of running performance. The variety of currently used assessment methods with different running intensities and outcomes restricts interindividual comparability of RE in recreational level runners. The purpose of this study was to compare the influence of RE, assessed as oxygen cost (OC) and caloric unit cost (CUC), on running speed at individual physiological thresholds. Eighteen recreational runners performed: 1) a graded exercise test to estimate first ventilatory threshold (VT1), respiratory compensation point (RCP) and maximal oxygen uptake (VO2max); 2) discontinuous RE assessment to determine relative OC in milliliters per kilogram per kilometer (mL/kg/km) and CUC in kilocalories per kilogram per kilometer (kcal/kg/km) at three different running intensities: VT1, RCP and at a third standardized reference point (TP) in between. OC (mL/kg/km; at VT1: 235.4±26.2; at TP: 227.8±23.4; at RCP: 224.9±21.9) and CUC (kcal/kg/km at VT1: 1.18±0.13; at TP: 1.14±0.12; at RCP: 1.13±0.11) decreased with increasing intensities (P≤0.01). Controlling for the influence of sex OC and CUC linearly correlated with running speed at RCP and VO2max (P≤0.01). RE, even assessed at low intensity, is strongly related to running performance in recreational athletes. Both calculation methods used (OC and CUC) are sensitive for monitoring intensity related changes of substrate utilization. RE values decreased with higher running intensity indicating an increase of anaerobic and subsequent decrease of aerobic substrate utilization.

  15. Capacitive divider for output voltage measurement of intense electron beam accelerator

    International Nuclear Information System (INIS)

    Ding Desheng; Yi Lingzhi; Yu Binxiong; Hong Zhiqiang; Liu Jinliang

    2012-01-01

    A kind of simple-mechanism, easy-disassembly self-integrating capacitive divider used for measuring diode output voltage of intense electron beam accelerator (IEBA) is developed. The structure of the capacitive divider is described, and the capacitance value of the capacitive divider is calculated by theoretical analysis and electromagnetic simulation. The dependence of measurement voltage on electrical parameters such as stray capacitance, earth capacitance of front resistance is obtained by PSpice simulation. Measured waveforms appear overshoot phenomenon when stray capacitance of front resistance is larger, and the wavefront will be affected when earth capacitance of front resistance is larger. The diode output voltage waveforms of intense electron beam accelerator, are measured by capacitive divider and calibrated by water resistance divider, which is accordance with that measured by a resistive divider, the division ratio is about 563007. The designed capacitive divider can be used to measure high-voltage pulse with 100 ns full width at half maximum. (authors)

  16. Funding intensive care - approaches in systems using diagnosis-related groups.

    OpenAIRE

    Ettelt, S; Nolte, E

    2010-01-01

    This report reviews approaches to funding intensive care in health systems that use activitybased payment mechanisms based on diagnosis-related groups (DRGs) to reimburse hospital care. The report aims to inform the current debate about options for funding intensive care services for adults, children and newborns in England. Funding mechanisms reviewed here include those in Australia (Victoria), Denmark, France, Germany, Italy, Spain, Sweden and the United States (Medicare). Approaches to org...

  17. Objective and subjective measures of exercise intensity during thermo-neutral and hot yoga.

    Science.gov (United States)

    Boyd, Corinne N; Lannan, Stephanie M; Zuhl, Micah N; Mora-Rodriguez, Ricardo; Nelson, Rachael K

    2018-04-01

    While hot yoga has gained enormous popularity in recent years, owing in part to increased environmental challenge associated with exercise in the heat, it is not clear whether hot yoga is more vigorous than thermo-neutral yoga. Therefore, the aim of this study was to determine objective and subjective measures of exercise intensity during constant intensity yoga in a hot and thermo-neutral environment. Using a randomized, crossover design, 14 participants completed 2 identical ∼20-min yoga sessions in a hot (35.3 ± 0.8 °C; humidity: 20.5% ± 1.4%) and thermo-neutral (22.1 ± 0.2 °C; humidity: 27.8% ± 1.6%) environment. Oxygen consumption and heart rate (HR) were recorded as objective measures (percentage of maximal oxygen consumption and percentage of maximal HR (%HRmax)) and rating of perceived exertion (RPE) was recorded as a subjective measure of exercise intensity. There was no difference in exercise intensity based on percentage of maximal oxygen consumption during hot versus thermo-neutral yoga (30.9% ± 2.3% vs. 30.5% ± 1.8%, p = 0.68). However, exercise intensity was significantly higher during hot versus thermo-neutral yoga based on %HRmax (67.0% ± 2.3% vs. 60.8% ± 1.9%, p = 0.01) and RPE (12 ± 1 vs. 11 ± 1, p = 0.04). According to established exercise intensities, hot yoga was classified as light-intensity exercise based on percentage of maximal oxygen consumption but moderate-intensity exercise based on %HRmax and RPE while thermo-neutral yoga was classified as light-intensity exercise based on percentage of maximal oxygen uptake, %HRmax, and RPE. Despite the added hemodynamic stress and perception that yoga is more strenuous in a hot environment, we observed similar oxygen consumption during hot versus thermo-neutral yoga, classifying both exercise modalities as light-intensity exercise.

  18. Motor intensive anti-gravity training improves performance in dynamic balance related tasks in persons with Parkinson's disease

    DEFF Research Database (Denmark)

    Malling, Anne Sofie Bøgh; Jensen, Bente Rona

    2016-01-01

    , the aim was to study the effect of motor intensive training performed in a safe anti-gravity environment using lower-body positive pressure (LBPP) technology on performance during dynamic balance related tasks. Thirteen male PDP went through an 8-week control period followed by 8 weeks of motor intensive...... antigravity training. Seventeen healthy males constituted a control group (CON). Performance during a five repetition sit-to-stand test (STS; sagittal plane) and a dynamic postural balance test (DPB; transversal plane) was evaluated. Effect measures were completion time, functional rates of force development...

  19. Health-related quality of life after prolonged pediatric intensive care unit stay.

    LENUS (Irish Health Repository)

    Conlon, Niamh P

    2012-02-01

    OBJECTIVE: To investigate the long-term health-related quality of life (HRQOL) outcomes for patients requiring at least 28 days of pediatric intensive care. DESIGN: Retrospective cohort and prospective follow-up study. SETTING: A 21-bed pediatric intensive care unit (PICU) in a university-affiliated, tertiary referral pediatric hospital. PATIENTS: One hundred ninety-three patients who spent 28 days or longer in the PICU between January 1, 1997 and December 31, 2004. INTERVENTIONS: Quality of life was measured using the Pediatric Quality of Life Inventory (Peds QL 4.0) parent-proxy version at 2 to 10 yrs after discharge. The PedsQL 4.0 is a modular measure of HRQOL, which is reliable in children aged 2 to 18 yrs. It generates a total score and physical, emotional, social, school, and psychosocial subscores. MEASUREMENTS AND MAIN RESULTS: Of the 193 patients, 41 died during their PICU admission and 27 died between PICU discharge and follow-up. Quality of life questionnaires were posted to parents of 108 of the 125 survivors and 70 were returned completed. Forty children (57.1%) had scores indicating a normal quality of life, whereas 30 (42.9%) had scores indicating impaired HRQOL. Of these, 14 (20%) had scores indicating poor quality of life with ongoing disabling health problems requiring hospitalization or the equivalent. CONCLUSIONS: Our results indicate that, while long PICU stay is associated with significant mortality, the long-term HRQOL is normal for the majority of surviving children.

  20. Earthworm assemblages in different intensity of agricultural uses and their relation to edaphic variables

    Directory of Open Access Journals (Sweden)

    LB Falco

    2015-05-01

    Full Text Available The objective of this study was to relate earthworm assemblage structure with three different soil use intensities, and to indentify the physical, chemical, and microbiological soil variables that are associated to the observed differences. Three soil uses were evaluated: 1-Fifty year old naturalized grasslands, low use intensity; 2-Recent agricultural fields, intermediate use intensity, and 3-Fifty year old intensive agricultural fields, high use intensity. Three different sites for each soil use were evaluated from winter 2008 through summer 2011. Nine earthworm species were identified across all sampling sites. The sites shared five species: the native Microscolex dubius, and the introduced Aporrectodea caliginosa, A. rosea, Octalasion cyaneum, and O. lacteum, but they differed in relative abundance by soil use. The results show that the earthworm community structure is linked to and modulated by soil properties. Both species abundance and diversity showed significant differences depending on soil use intensity. A principal component analysis showed that species composition is closely related to the environmental variability. The ratio of native to exotic species was significantly lower in the intensive agricultural system when compared to the other two, lower disturbance systems. Microscolex dubius abundance was related to naturalized grasslands along with soil Ca, pH, mechanical resistance, and microbial respiration. Aporrectodea caliginosa abundance was related to high K levels, low enzymatic activity, slightly low pH, low Ca, and appeared related to the highly disturbed environment. Eukerria stagnalis and Aporrectodea rosea, commonly found in the recent agricultural system, were related to high soil moisture condition, low pH, low Ca and low enzymatic activity. These results show that earthworm assemblages can be good indicators of soil use intensities. In particular, Microscolex dubius, Aporrectodea caliginosa, and Aporrectodea rosea

  1. 124Sb - Activity measurement and determination of photon emission intensities

    International Nuclear Information System (INIS)

    Be, M.M.; Chauvenet, B.

    2009-07-01

    The international traceability of antimony 124, in term of activity, is very limited. The results of 124 Sb activity measurements sent to the SIR (BIPM - International System of Reference, BIPM.RI(II)-K1.Sb-124.) are scarce. Up to now, only three laboratories have contributed. Two of them carried out measurements using the 4πβ-γ coincidence counting technique and the third one using the 4πγ method with a well-type crystal detector. The first two results are in agreement but the last one differs significantly from them, by 2 %. The decay scheme consistency cannot be excluded when trying to explain those discrepancies. In other respects, this nuclide emits high-energy gamma rays, and then could be selected as a valuable standard radionuclide for the calibration of gamma-ray detectors in that energy range, given well known photon intensities. Those considerations led to the proposal of an international exercise and to the realisation of this Euromet project, registered as project no. 907, coordinated by CEA-List-LNE/LNHB. The first part of this exercise was dedicated to activity measurements and to their comparison. For this purpose, participants were asked to make use of all the direct measurement techniques available in their laboratory in order to confirm or not the existence of possible biases specific to some measuring methods. In addition, this exercise offered the opportunity of improving the uncertainties of the gamma-ray intensities. Then, participants were asked, in the second part of the exercise, to carry out X-ray and gamma-ray intensity measurements. These results have been compared to previous published values and new decay scheme data are proposed. Eight international laboratories participated in this exercise. (authors)

  2. Measurement of L X-ray intensity ratios in tantalum by proton and Si-ion impact

    International Nuclear Information System (INIS)

    Braich, J.S.; Dhal, B.B.; Singh, B.P.; Padhi, H.C.; Khurana, C.S.; Verma, H.R.

    1996-01-01

    The Lι, Lβ 1,4,6 , Lβ 2,15,3 , Lγ 1 , Lγ 2,3,6 and Lγ 4,4' , X-ray intensities relative to the Lα, caused by the impact of protons of energy 1 to 4.6 MeV and Si-ions of 70 to 98 MeV on Ta targets, h ave been measured. The results show that the intensity ratios drop significantly for all transitions except Lγ 2,3,6 /Lα with Si-ions of the same energy/amu as compared to those of protons. The experimental results have been compared with those based on the ECPSSR theoretical values. From the energy shift and change in the intensity ratios of various transitions caused by Si-ion impact, the number of outer shell vacancies in the M, N and O-shells simultaneous to that of L-shell have been estimat ed. (orig.)

  3. Tennis Play Intensity Distribution and Relation with Aerobic Fitness in Competitive Players.

    Directory of Open Access Journals (Sweden)

    Ernest Baiget

    Full Text Available The aims of this study were (i to describe the relative intensity of simulated tennis play based on the cumulative time spent in three metabolic intensity zones, and (ii to determine the relationships between this play intensity distribution and the aerobic fitness of a group of competitive players. 20 male players of advanced to elite level (ITN performed an incremental on-court specific endurance tennis test to exhaustion to determine maximal oxygen uptake (VO2max and the first and second ventilatory thresholds (VT1, VT2. Ventilatory and gas exchange parameters were monitored using a telemetric portable gas analyser (K4 b2, Cosmed, Rome, Italy. Two weeks later the participants played a simulated tennis set against an opponent of similar level. Intensity zones (1: low, 2: moderate, and 3: high were delimited by the individual VO2 values corresponding to VT1 and VT2, and expressed as percentage of maximum VO2 and heart rate. When expressed relative to VO2max, percentage of playing time in zone 1 (77 ± 25% was significantly higher (p < 0.001 than in zone 2 (20 ± 21% and zone 3 (3 ± 5%. Moderate to high positive correlations were found between VT1, VT2 and VO2max, and the percentage of playing time spent in zone 1 (r = 0.68-0.75, as well as low to high inverse correlations between the metabolic variables and the percentage of time spent in zone 2 and 3 (r = -0.49-0.75. Players with better aerobic fitness play at relatively lower intensities. We conclude that players spent more than 75% of the time in their low-intensity zone, with less than 25% of the time spent at moderate to high intensities. Aerobic fitness appears to determine the metabolic intensity that players can sustain throughout the game.

  4. Reconstructing the long-term cosmic ray intensity: linear relations do not work

    Directory of Open Access Journals (Sweden)

    K. Mursula

    2003-04-01

    Full Text Available It was recently suggested (Lockwood, 2001 that the cosmic ray intensity in the neutron monitor energy range is linearly related to the coronal source flux, and can be reconstructed for the last 130 years using the long-term coronal flux estimated earlier. Moreover, Lockwood (2001 reconstructed the coronal flux for the last 500 years using a similar linear relation between the flux and the concentration of cosmogenic 10 Be isotopes in polar ice. Here we show that the applied linear relations are oversimplified and lead to unphysical results on long time scales. In particular, the cosmic ray intensity reconstructed by Lockwood (2001 for the last 130 years has a steep trend which is considerably larger than the trend estimated from observations during the last 65 years. Accordingly, the reconstructed cosmic ray intensity reaches or even exceeds the local interstellar cosmic ray flux around 1900. We argue that these unphysical results obtained when using linear relations are due to the oversimplified approach which does not take into account the complex and essentially nonlinear nature of long-term cosmic ray modulation in the heliosphere. We also compare the long-term cosmic ray intensity based on a linear treatment with the reconstruction based on a recent physical model which predicts a considerably lower cosmic ray intensity around 1900.Key words. Interplanetary physics (cosmic rays; heliopause and solar wind termination – Geomagnetism and paleomagnetism (time variations, secular and long-term

  5. High-effective position time spectrometer in actual measurements of low intensity region of electron spectra

    International Nuclear Information System (INIS)

    Babenkov, M.I.; Zhdanov, V.S.

    2002-01-01

    Magnetic position-time spectrometer was proposed in previous work, where not only electron coordinates in focal plane are measured by position sensitive detector (PSD) but places of their birth in beta source plane of a large area are fixed using another PSD, situated behind it, by quick effects, accompanying radioactive decay. PSD on the basis of macro-channel plates are used. It is succeeded in position-time spectrometer to combine beta sources of a large area with multichannel registration for a wide energy interval, that efficiency of measurements was two orders of magnitude increase d in comparison magnetic apparatus having PSD only in focal plane. Owing to two detectors' switching on coincidence the relation effect/background in increased minimum on two orders of magnitude in comparison with the same apparatus. At some complication of mathematical analysis it was obtained, that high characteristics of position-time spectrometer are kept during the use the magnetic field, providing double focusing. Owning to this focusing the gain the efficiency of measurements will make one more order of magnitude. Presented high-effective position-time spectrometer is supposed to use in the measurements of low-intensity region of electron spectra, which are important for development of fundamental physics. This is the first of all estimation of electron anti-neutrino mass by the form of beta spectrum of tritium in the region of boundary energy. Recently here there was problem of non physical negative values. This problem can be solved by using in measurement of different in principle high-effective spectrometers, which possess improved background properties. A position-time spectrometers belongs to these apparatus, which provides the best background conditions at very large effectiveness of the measurements of tritium beta spectrum in the region of boundary energy with acceptable high resolution. An important advantage of position-time spectrometer is the possibility of

  6. Social Relation between Businessman and Community in Management of Intensive Shrimp Pond

    Science.gov (United States)

    Gumay Febryano, Indra; Sinurat, James; Lovinia Salampessy, Messalina

    2017-02-01

    Expansion of aquaculture, especially shrimp culture, is the primary cause of deforestation of mangrove along coastal zone. This phenomenon is pretty much related to social relation between businessman of intensive shrimp pond and community around coastal zone. The objective of this research is to explain social relation between businessman and community in managing intensive shrimp pond. This research is a kind of qualitative research and the method used is a case study. The result of this research shows that the behaviour of the majority of businessman of intensive shrimp pond is not accordingly with environmental concerns as they compelled conversion of mangrove and they disposed waste of shrimp pond into the sea. Such kind of behaviour caused degradation of water ecosystem and marginalizing local community. Corporate Social Responsibility (CSR) which was implemented by businessman of intensive shrimp pond in the area of social, religion, and education can downgrade the coming up of social turbulence. Otherwise, CSR in enabling economic community and environmental management was not conducted yet. CSR in environmental management can be conducted by businessman of intensive shrimp pond by considering the existence of mangrove and pond management and waste in a better way, so that environment around ponds is not polluted and the sustainability of shrimp pond business as well as income of community can be guaranteed. Accordingly with the result of this research, CSR is not only involving businessman of intensive shrimp pond and community, but also involving local government in terms of right and responsibility of citizen as well as management and development of community.

  7. A photodiode amplifier system for pulse-by-pulse intensity measurement of an x-ray free electron laser.

    Science.gov (United States)

    Kudo, Togo; Tono, Kensuke; Yabashi, Makina; Togashi, Tadashi; Sato, Takahiro; Inubushi, Yuichi; Omodani, Motohiko; Kirihara, Yoichi; Matsushita, Tomohiro; Kobayashi, Kazuo; Yamaga, Mitsuhiro; Uchiyama, Sadayuki; Hatsui, Takaki

    2012-04-01

    We have developed a single-shot intensity-measurement system using a silicon positive-intrinsic-negative (PIN) photodiode for x-ray pulses from an x-ray free electron laser. A wide dynamic range (10(3)-10(11) photons/pulse) and long distance signal transmission (>100 m) were required for this measurement system. For this purpose, we developed charge-sensitive and shaping amplifiers, which can process charge pulses with a wide dynamic range and variable durations (ns-μs) and charge levels (pC-μC). Output signals from the amplifiers were transmitted to a data acquisition system through a long cable in the form of a differential signal. The x-ray pulse intensities were calculated from the peak values of the signals by a waveform fitting procedure. This system can measure 10(3)-10(9) photons/pulse of ~10 keV x-rays by direct irradiation of a silicon PIN photodiode, and from 10(7)-10(11) photons/pulse by detecting the x-rays scattered by a diamond film using the silicon PIN photodiode. This system gives a relative accuracy of ~10(-3) with a proper gain setting of the amplifiers for each measurement. Using this system, we succeeded in detecting weak light at the developmental phase of the light source, as well as intense light during lasing of the x-ray free electron laser. © 2012 American Institute of Physics

  8. Mechanical Design of the Intensity Measurement Devices for the LHC

    CERN Document Server

    Belorhad, D; Odier, P; Thoulet, S

    2008-01-01

    The intensity measurement for the LHC ring is provided by eight current transformers (2×DCCT, 2×FBCT per beam). The measurement resolution of 1?Arms at 1s average for the DCCTs and ±10^9p in 25ns for the FBCTs is required. Such constraints call for low noise electronics and a compact magnetically shielded mechanical design. Correct integration of these devices into the vacuum system also requires the vacuum chambers equipped with the non-evaporable getter (NEG) film. The NEG is activated by heating the vacuum chamber to 200?C and more. Such temperatures affect the structure of the magnetic materials, which form the base part of the intensity measurement devices, and degrade their performace. A cooling circuit is needed. Due to the mechanical constraints, the cooling circuit, as well as heating element must form an integral part of the design. The aim of this paper is to present the solutions to these problems and discuss the mechanical construction of the DCCTs and FBCTs currently being installed in the LH...

  9. Optimal distribution of integration time for intensity measurements in degree of linear polarization polarimetry.

    Science.gov (United States)

    Li, Xiaobo; Hu, Haofeng; Liu, Tiegen; Huang, Bingjing; Song, Zhanjie

    2016-04-04

    We consider the degree of linear polarization (DOLP) polarimetry system, which performs two intensity measurements at orthogonal polarization states to estimate DOLP. We show that if the total integration time of intensity measurements is fixed, the variance of the DOLP estimator depends on the distribution of integration time for two intensity measurements. Therefore, by optimizing the distribution of integration time, the variance of the DOLP estimator can be decreased. In this paper, we obtain the closed-form solution of the optimal distribution of integration time in an approximate way by employing Delta method and Lagrange multiplier method. According to the theoretical analyses and real-world experiments, it is shown that the variance of the DOLP estimator can be decreased for any value of DOLP. The method proposed in this paper can effectively decrease the measurement variance and thus statistically improve the measurement accuracy of the polarimetry system.

  10. Third-order optical intensity correlation measurements of pseudo-thermal light

    International Nuclear Information System (INIS)

    Chen Xi-Hao; Wu Wei; Meng Shao-Ying; Li Ming-Fei

    2014-01-01

    Third-order Hanbrury Brown—Twiss and double-slit interference experiments with a pseudo-thermal light are performed by recording intensities in single, double and triple optical paths, respectively. The experimental results verifies the theoretical prediction that the indispensable condition for achieving a interference pattern or ghost image in Nth-order intensity correlation measurements is the synchronous detection of the same light field by each reference detector, no matter the intensities recorded in one, or two, or N optical paths. It is shown that, when the reference detectors are scanned in the opposite directions, the visibility and resolution of the third-order spatial correlation function of thermal light is much better than that scanned in the same direction, but it is no use for obtaining the Nth-order interference pattern or ghost image in the thermal Nth-order interference or ghost imaging. (general)

  11. Raman overtone intensities measured for H2

    International Nuclear Information System (INIS)

    Shelton, D.P.

    1990-01-01

    The Raman spectra of the vibrational fundamental, first overtone and second overtone transitions of the H 2 molecule were recorded using visible and ultraviolet argon--ion laser excitation. The ratios of transition polarizability matrix elements, α 01,21 /α 01,11 and α 01,31 /α 01,11 , were determined from the measured intensities of the Q(1) Raman lines v,J=0,1→v',1 for v'=1,2,3. The experimentally determined value of the Raman first overtone matrix element is in good agreement with the value from the best ab initio calculation

  12. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... For this reason, some items on this page will be unavailable. For more information about this message, ... If you're doing vigorous-intensity activity, you will not be able to say more than a ...

  13. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Intensity The amount of energy used by the body per minute of activity. The table below lists ... upon the amount of energy used by the body while doing the activity. Top of Page Moderate ...

  14. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... miles per hour Tennis (doubles) Ballroom dancing General gardening Vigorous Intensity Race walking, jogging, or running Swimming ... miles per hour or faster Jumping rope Heavy gardening (continuous digging or hoeing) Hiking uphill or with ...

  15. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... The amount of energy used by the body per minute of activity. The table below lists examples ... of Page Moderate Intensity Walking briskly (3 miles per hour or faster, but not race-walking) Water ...

  16. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... be able to say more than a few words without pausing for a breath. Absolute Intensity The ... site? Adobe PDF file Microsoft PowerPoint file Microsoft Word file Microsoft Excel file Audio/Video file Apple ...

  17. Coronal mass ejections, interplanetary shocks in relation with forbush decreases associated with intense geomagnetic storms

    International Nuclear Information System (INIS)

    Verma, P L; Patel, Nand Kumar; Prajapati, Mateswari

    2014-01-01

    Coronal mass ejections (CMEs} are the most energetic solar events in which large amount of solar plasma materials are ejected from the sun into heliosphere, causing major disturbances in solar wind plasma, Interplanetary shocks, Forbush decrease(Fds) in cosmic ray intensity and geomagnetic storms. We have studied Forbush decreases associated with intense geomagnetic storms observed at Oulu super neutron monitor, during the period of May 1998-Dec 2006 with coronal mass ejections (CMEs), X-ray solar flares and interplanetary shocks. We have found that all the (100%) Forbush decreases associated with intense geomagnetic storms are associated with halo and partial halo coronal mass ejections (CMEs). The association rate between halo and partial halo coronal mass ejections are found 96.00%and 04.00% respectively. Most of the Forbush decreases associated with intense geomagnetic storms (96.29%) are associated with X-ray solar flares of different categories . The association rates for X-Class, M-Class, and C- Class X -ray solar flares are found 34.62%, 50.00% and 15.38% respectively .Further we have concluded that majority of the Forbush decrease associated with intense geomagnetic storms are related to interplanetary shocks (92.30 %) and the related shocks are forward shocks. We have found positive co-relation with co-relation co-efficient .7025 between magnitudes of Forbush decreases associated with intense geomagnetic storms and speed of associated coronal mass ejections. Positive co-relation with co-relation co-efficient 0.48 has also been found between magnitudes of intense geomagnetic storms and speed of associated coronal mass ejections.

  18. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Updates To receive email updates about this page, enter your email address: Enter Email Address What's this? Submit What's this? Submit ... Intensity Walking briskly (3 miles per hour or faster, but not race-walking) Water aerobics Bicycling slower ...

  19. Age-related patterns of vigorous-intensity physical activity in youth: The International Children's Accelerometry Database

    Directory of Open Access Journals (Sweden)

    Kirsten Corder

    2016-12-01

    Age-related declines in vigorous-intensity activity during youth appear relatively greater than those of moderate activity. However, due to a higher baseline, absolute moderate-intensity activity decreases more than vigorous. Overweight/obese individuals, girls, and North Americans appear especially in need of vigorous-intensity activity promotion due to low levels at 5.0–5.9 y and larger negative annual differences.

  20. Counterbalancing work-related stress? Work engagement among intensive care professionals.

    Science.gov (United States)

    van Mol, Margo M C; Nijkamp, Marjan D; Bakker, Jan; Schaufeli, Wilmar B; Kompanje, Erwin J O

    2018-07-01

    Working in an Intensive Care Unit (ICU) is increasingly complex and is also physically, cognitively and emotionally demanding. Although the negative emotions of work-related stress have been well studied, the opposite perspective of work engagement might also provide valuable insight into how these emotional demands may be countered. This study focused on the work engagement of ICU professionals and explored the complex relationship between work engagement, job demands and advantageous personal resources. This was a cross-sectional survey study among ICU professionals in a single-centre university hospital. Work engagement was measured by the Utrecht Work Engagement Scale, which included items about opinions related to the respondent's work environment. Additionally, 14 items based on the Jefferson Scale of Physician Empathy were included to measure empathic ability. A digital link to the questionnaire was sent in October 2015 to a population of 262 ICU nurses and 53 intensivists. The overall response rate was 61% (n=193). Work engagement was negatively related both to cognitive demands among intensivists and to emotional demands among ICU nurses. No significant relationship was found between work engagement and empathic ability; however, agreeableness, conscientiousness, and emotional stability were highly correlated with work engagement. Only the number of hours worked per week remained as a confounding factor, with a negative effect of workload on work engagement after controlling for the effect of weekly working hours. Work engagement counterbalances work-related stress reactions. The relatively high workload in ICUs, coupled with an especially heavy emotional burden, may be acknowledged as an integral part of ICU work. This workload does not affect the level of work engagement, which was high for both intensivists and nurses despite the known high job demands. Specific factors that contribute to a healthy and successful work life among ICU professionals need

  1. Changes in carbon intensity in China. Empirical findings from 1980-2003

    International Nuclear Information System (INIS)

    Fan, Ying; Wei, Yi-Ming; Liu, Lan-Cui; Wu, Gang; Tsai, Hsien-Tang

    2007-01-01

    China experienced sustainable, rapid economic growth over the period 1980-2003 but, at the same time, energy-related carbon intensity showed a downward trend. It begs the question, therefore, what factors were driving this decline in carbon intensity and will this decline be maintained in future? Moreover, what measures can be adopted to ensure a continual decline in carbon intensity? These questions led to increased research in the factors governing CO 2 emission in China. This paper quantifies the driving force behind China's primary energy-related carbon intensity and measures the material production sectors' final energy-related carbon intensity. Our results show that the overwhelming contributor to the decline of energy-related carbon intensity was the reduction in real energy intensity. However, policies that focus only on the decline in energy intensity are insufficient to further decrease carbon intensity. The change of primary energy mix can improve the decline of carbon intensity. This should focus on the material production sectors' development strategies and final energy use. Greater emphasis should be given to secondary industry, which needs national and regional governments' policy support. (author)

  2. Fast-electron-relaxation measurement for laser-solid interaction at relativistic laser intensities

    International Nuclear Information System (INIS)

    Chen, H.; Shepherd, R.; Chung, H. K.; Kemp, A.; Hansen, S. B.; Wilks, S. C.; Ping, Y.; Widmann, K.; Fournier, K. B.; Beiersdorfer, P.; Dyer, G.; Faenov, A.; Pikuz, T.

    2007-01-01

    We present measurements of the fast-electron-relaxation time in short-pulse (0.5 ps) laser-solid interactions for laser intensities of 10 17 , 10 18 , and 10 19 W/cm 2 , using a picosecond time-resolved x-ray spectrometer and a time-integrated electron spectrometer. We find that the laser coupling to hot electrons increases as the laser intensity becomes relativistic, and that the thermalization of fast electrons occurs over time scales on the order of 10 ps at all laser intensities. The experimental data are analyzed using a combination of models that include Kα generation, collisional coupling, and plasma expansion

  3. FBCT fast intensity measurement using TRIC cards

    CERN Document Server

    Allica, J C; Belohrad, D; Jensen, L; Lenardon, F; SØby, L

    2015-01-01

    At the CERN PS complex, precise fast intensity measurements are very important in order to optimize the transfer efficiencies between the different accelerators. Over the last two years a complete renovation has been ongoing, where the old electronics, based on analogue integrators, have been replaced by a fully digital system enclosed in a single VME based card. This new system called TRIC (Transformer Integration Card) is based on a 12 bit, 212 MS/s ADC and an FPGA for the signal processing. Also located on the same board one finds a 250 V/1.5 W DCDC converter used to generate precise calibration pulses.

  4. [Post-traumatic stress disorder-related to intensive care stay: influence of sedation practices].

    Science.gov (United States)

    Bauerheim, Nadège; Masseret, Elodie; Mercier, Emmanuelle; Dequin, Pierre-François; El-Hage, Wissam

    2013-03-01

    The stay in intensive care unit can be potentially traumatic at the origin of post-traumatic stress symptoms. The severity of post-traumatic stress symptoms is linked to the intensity and the type of traumatic memories of the intensive care stay. Sedatives and analgesics given to ventilated patients in intensive care influence the traumatic memory. The level, the duration and the type of sedation-analgesia protocol are risk factors of post-traumatic stress symptoms. Links between sedation, dissociative symptoms, delirium and post-traumatic stress symptoms are documented. Environmental and pharmacological measures are to be considered to reduce the traumatic potential risk of the intensive care. Intensive care caregivers, liaison-psychiatrist and general practitioner have each a specific role to play in the screening of the post-traumatic stress symptoms. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  5. Coping With Staff Burnout and Work-Related Posttraumatic Stress in Intensive Care.

    Science.gov (United States)

    Colville, Gillian A; Smith, Jared G; Brierley, Joe; Citron, Kim; Nguru, Noreen M; Shaunak, Priyanka D; Tam, Olivia; Perkins-Porras, Linda

    2017-07-01

    To examine the associations with symptoms of 1) burnout and 2) work-related posttraumatic stress, in adult and pediatric intensive care staff, focusing on the particular contributions of resilience and coping strategies. Point prevalence cross-sectional study. Three adult ICUs and four PICUs. Three hundred seventy-seven ICU staff. None. Brief Resilience Scale, abbreviated Maslach Burnout Inventory, Trauma Screening Questionnaire, and Hospital Anxiety and Depression Scale. Prevalence of burnout (defined as high emotional exhaustion or high depersonalization) was 37%. Prevalence of clinically significant posttraumatic stress symptoms was 13%. There was a degree of overlap between burnout and other measures of distress, most notably for anxiety (odds ratio, 10.56; 95% CI, 4.12-27.02; p work-related distress (burnout: odds ratio, 0.52; 95% CI, 0.36-0.74; p stress: odds ratio, 0.28; 95% CI, 0.16-0.46; p stress were less if staff used talking to seniors (odds ratio, 0.43; 95% CI, 0.20-0.92; p = 0.029) or hobbies (odds ratio, 0.46; 95% CI, 0.23-0.93; p = 0.030) to cope with stress at work. Venting emotion (odds ratio, 1.92; 95% CI, 1.12-3.31; p = 0.018) and using alcohol (odds ratio, 2.30; 95% CI, 1.26-4.20; p = 0.006) were associated with a doubling in risk of reporting burnout. The use of particular coping strategies was systematically associated with symptoms of burnout and work-related posttraumatic stress in this group of intensive care staff, even after controlling for resilience and other factors. More research on how best to promote adaptive coping is needed in these challenging settings.

  6. Gasdynamic measurements for the LASL intense neutron source

    International Nuclear Information System (INIS)

    Johnston, S.C.

    1978-02-01

    Measurements made on a two-dimensional simulation of the Los Alamos Scientific Laboratory (LASL) Intense Neutron Source (INS) experiment are discussed. The purpose of this work was to characterize the supersonic INS channel flow under conditions of large amounts of energy deposition. Nozzle channel wall pressure measurements, cold flow leakage rates, vacuum channel pressure and Mach number, leakage flow rates with mass addition to and momentum extraction from the main flow, and flow visualization photographs are given. Energy addition up to thirty percent of the theoretical maximum was achieved via mass addition to and momentum extraction from the main channel flow. In this range, both a weak and strong regime for leakage flow were identified. These regimes differed by about twenty percent in leakage flow rates

  7. Propagation based phase retrieval of simulated intensity measurements using artificial neural networks

    Science.gov (United States)

    Kemp, Z. D. C.

    2018-04-01

    Determining the phase of a wave from intensity measurements has many applications in fields such as electron microscopy, visible light optics, and medical imaging. Propagation based phase retrieval, where the phase is obtained from defocused images, has shown significant promise. There are, however, limitations in the accuracy of the retrieved phase arising from such methods. Sources of error include shot noise, image misalignment, and diffraction artifacts. We explore the use of artificial neural networks (ANNs) to improve the accuracy of propagation based phase retrieval algorithms applied to simulated intensity measurements. We employ a phase retrieval algorithm based on the transport-of-intensity equation to obtain the phase from simulated micrographs of procedurally generated specimens. We then train an ANN with pairs of retrieved and exact phases, and use the trained ANN to process a test set of retrieved phase maps. The total error in the phase is significantly reduced using this method. We also discuss a variety of potential extensions to this work.

  8. A laboratory assessment of the measurement accuracy of weighing type rainfall intensity gauges

    Science.gov (United States)

    Colli, M.; Chan, P. W.; Lanza, L. G.; La Barbera, P.

    2012-04-01

    In recent years the WMO Commission for Instruments and Methods of Observation (CIMO) fostered noticeable advancements in the accuracy of precipitation measurement issue by providing recommendations on the standardization of equipment and exposure, instrument calibration and data correction as a consequence of various comparative campaigns involving manufacturers and national meteorological services from the participating countries (Lanza et al., 2005; Vuerich et al., 2009). Extreme events analysis is proven to be highly affected by the on-site RI measurement accuracy (see e.g. Molini et al., 2004) and the time resolution of the available RI series certainly constitutes another key-factor in constructing hyetographs that are representative of real rain events. The OTT Pluvio2 weighing gauge (WG) and the GEONOR T-200 vibrating-wire precipitation gauge demonstrated very good performance under previous constant flow rate calibration efforts (Lanza et al., 2005). Although WGs do provide better performance than more traditional Tipping Bucket Rain gauges (TBR) under continuous and constant reference intensity, dynamic effects seem to affect the accuracy of WG measurements under real world/time varying rainfall conditions (Vuerich et al., 2009). The most relevant is due to the response time of the acquisition system and the derived systematic delay of the instrument in assessing the exact weight of the bin containing cumulated precipitation. This delay assumes a relevant role in case high resolution rain intensity time series are sought from the instrument, as is the case of many hydrologic and meteo-climatic applications. This work reports the laboratory evaluation of Pluvio2 and T-200 rainfall intensity measurements accuracy. Tests are carried out by simulating different artificial precipitation events, namely non-stationary rainfall intensity, using a highly accurate dynamic rainfall generator. Time series measured by an Ogawa drop counter (DC) at a field test site

  9. Nutrition therapy with high intensity interval training to improve prostate cancer-related fatigue in men on androgen deprivation therapy: a study protocol.

    Science.gov (United States)

    Baguley, Brenton J; Skinner, Tina L; Leveritt, Michael D; Wright, Olivia R L

    2017-01-03

    Cancer-related fatigue is one of the most prevalent, prolonged and distressing side effects of prostate cancer treatment with androgen deprivation therapy. Preliminary evidence suggests natural therapies such as nutrition therapy and structured exercise prescription can reduce symptoms of cancer-related fatigue. Men appear to change their habitual dietary patterns after prostate cancer diagnosis, yet prostate-specific dietary guidelines provide limited support for managing adverse side effects of treatment. The exercise literature has shown high intensity interval training can improve various aspects of health that are typically impaired with androgen deprivation therapy; however exercise at this intensity is yet to be conducted in men with prostate cancer. The purpose of this study is to examine the effects of nutrition therapy beyond the current healthy eating guidelines with high intensity interval training for managing cancer-related fatigue in men with prostate cancer treated with androgen deprivation therapy. This is a two-arm randomized control trial of 116 men with prostate cancer and survivors treated with androgen deprivation therapy. Participants will be randomized to either the intervention group i.e. nutrition therapy and high intensity interval training, or usual care. The intervention group will receive 20 weeks of individualized nutrition therapy from an Accredited Practising Dietitian, and high intensity interval training (from weeks 12-20 of the intervention) from an Accredited Exercise Physiologist. The usual care group will maintain their standard treatment regimen over the 20 weeks. Both groups will undertake primary and secondary outcome testing at baseline, week 8, 12, and 20; testing includes questionnaires of fatigue and quality of life, objective measures of body composition, muscular strength, cardiorespiratory fitness, biomarkers for disease progression, as well as dietary analysis. The primary outcomes for this trial are measures of

  10. The revised program for measurements in intense operation mode according to AVV-IMIS

    International Nuclear Information System (INIS)

    Bieringer, J.; Wirth, E.; Buehling, A.; Mueller-Neumann, M.; Haase, G.; Heinrich, T.; Steinkopff, T.; Wiezorek, C.

    2007-01-01

    The monitoring program for measurements in intense operation mode has been revised recently by a working group at the Federal Ministry for Environment, Nature Conservation and Reactor Safety (BMU). The major issues of the revision are reported in this contribution. Measurements in intense operation must be appropriate for fast assessment of the radiological situation, for estimating the dose to the population and for decisions on countermeasures to minimize the dose. In order to meet these requirements the structure of the measurement program in intense operation mode was divided into three phases when different exposition paths are relevant: before and during dispersion of radioactive material, immediately after dispersion of radioactive material has ended and a late phase when contamination values have decreased in different environmental media. For each of these phases a special measurement program was defined that is tailored to achieve the above mentioned objectives. Minimum detectable activity concentrations were introduced similar to the measurement program in routine operation mode. They follow the intervention levels in the catalogue of countermeasures and maximum permitted values given by the European Union (EU) for food and animal feed. The minimum detectable activity concentrations were defined such that the detection of 1/10 of the intervention levels for countermeasures is ensured. (orig.)

  11. Relative SHG measurements of metal thin films: Gold, silver, aluminum, cobalt, chromium, germanium, nickel, antimony, titanium, titanium nitride, tungsten, zinc, silicon and indium tin oxide

    Directory of Open Access Journals (Sweden)

    Franklin Che

    Full Text Available We have experimentally measured the surface second-harmonic generation (SHG of sputtered gold, silver, aluminum, zinc, tungsten, copper, titanium, cobalt, nickel, chromium, germanium, antimony, titanium nitride, silicon and indium tin oxide thin films. The second-harmonic response was measured in reflection using a 150 fs p-polarized laser pulse at 1561 nm. We present a clear comparison of the SHG intensity of these films relative to each other. Our measured relative intensities compare favorably with the relative intensities of metals with published data. We also report for the first time to our knowledge the surface SHG intensity of tungsten and antimony relative to that of well known metallic thin films such as gold and silver. Keywords: Surface second-harmonic generation, Nonlinear optics, Metal thin films

  12. Interrelationships between measured running intensities and agility performance in subelite rugby union players.

    Science.gov (United States)

    Jarvis, Stuart; Sullivan, Lee O; Davies, Bruce; Wiltshire, Huw; Baker, Julien S

    2009-01-01

    The purpose of this study was to investigate agility performance of rugby players using various intensity running tests. A further aim was to investigate if any differences existed between playing positions in relation to agility performance. Nineteen subelite players (mean +/- SD age, 23.0 +/- 5.4 years) participated in the study. Players underwent measurements of anthropometry (height, body mass, and sum of four skinfolds). Running tests investigated were speed (10 m and 40 m sprint), agility (T Test and Illinois), and multistage fitness tests (20 m, 10 m, and 5 m), with all tests for agility measured against the Illinois agility test. Results indicated that backline players produced significant correlations (P rugby-specific agility programs to aid performance may be of greater benefit and of higher priority in training programs designed for backs rather than forwards.

  13. Research on temperature measurement by X-ray transmission intensity

    International Nuclear Information System (INIS)

    Chen, Shuyue; Cheng, Rong

    2013-01-01

    The relationship between temperature and X-ray transmission intensity was researched and analyzed by inspecting material density change, which is caused by thermal expansion. A digital radiographic system was employed to obtain the images. On this basis, we deduced the temperature formula based on the average gray level of the captured images. The measured temperatures were obtained from the experiments and the errors were analyzed. We concluded that when X-rays pass through an object, the X-ray strength and the gray level of the image under high temperatures are greater than those under lower temperatures and the image gray level error has great impact on the accuracy of the measured temperature. The presented approach allowed the non-contact temperature measurement of material

  14. Bathyphotometer bioluminescence potential measurements: A framework for characterizing flow agitators and predicting flow-stimulated bioluminescence intensity

    Science.gov (United States)

    Latz, Michael I.; Rohr, Jim

    2013-07-01

    Bathyphotometer measurements of bioluminescence are used as a proxy for the abundance of luminescent organisms for studying population dynamics; the interaction of luminescent organisms with physical, chemical, and biological oceanographic processes; and spatial complexity especially in coastal areas. However, the usefulness of bioluminescence measurements has been limited by the inability to compare results from different bathyphotometer designs, or even the same bathyphotometer operating at different volume flow rates. The primary objective of this study was to compare measurements of stimulated bioluminescence of four species of cultured dinoflagellates, the most common source of bioluminescence in coastal waters, using two different bathyphotometer flow agitators as a function of bathyphotometer volume flow rate and dinoflagellate concentration. For both the NOSC and BIOLITE flow agitators and each species of dinoflagellate tested, there was a critical volume flow rate, above which average bioluminescence intensity, designated as bathyphotometer bioluminescence potential (BBP), remained relatively constant and scaled directly with dinoflagellate cell concentration. At supra-critical volume flow rates, the ratio of BIOLITE to NOSC BBP was nearly constant for the same species studied, but varied between species. The spatial pattern and residence time of flash trajectories within the NOSC flow agitator indicated the presence of dominant secondary recirculating flows, where most of the bioluminescence was detected. A secondary objective (appearing in the Appendix) was to study the feasibility of using NOSC BBP to scale flow-stimulated bioluminescence intensity across similar flow fields, where the contributing composition of luminescent species remained the same. Fully developed turbulent pipe flow was chosen because it is hydrodynamically well characterized. Average bioluminescence intensity in a 2.54-cm i.d. pipe was highly correlated with wall shear stress and

  15. Theoretical background and experimental measurements of human brain noise intensity in perception of ambiguous images

    International Nuclear Information System (INIS)

    Runnova, Anastasiya E.; Hramov, Alexander E.; Grubov, Vadim V.; Koronovskii, Alexey A.; Kurovskaya, Maria K.; Pisarchik, Alexander N.

    2016-01-01

    We propose a theoretical approach associated with an experimental technique to quantitatively characterize cognitive brain activity in the perception of ambiguous images. Based on the developed theoretical background and the obtained experimental data, we introduce the concept of effective noise intensity characterizing cognitive brain activity and propose the experimental technique for its measurement. The developed theory, using the methods of statistical physics, provides a solid experimentally approved basis for further understanding of brain functionality. The rather simple way to measure the proposed quantitative characteristic of the brain activity related to the interpretation of ambiguous images will hopefully become a powerful tool for physicists, physiologists and medics. Our theoretical and experimental findings are in excellent agreement with each other.

  16. The Use of Satellite Microwave Rainfall Measurements to Predict Eastern North Pacific Tropical Cyclone Intensity

    National Research Council Canada - National Science Library

    West, Derek

    1998-01-01

    .... Relationships between parameters obtained from an operational SSM/I based rainfall measuring algorithm and current intensity and ensuing 12, 24, 36, 48, 60, and 72 hour intensity changes from best...

  17. Measurement of guided light-mode intensity: An alternative waveguide sensing principle

    DEFF Research Database (Denmark)

    Horvath, R.; Skivesen, N.; Pedersen, H.C.

    2004-01-01

    An alternative transduction mechanism for planar optical waveguide sensors is reported. Based on a simple measurement of the mode intensity, the presented transduction is an interesting alternative to the conventional mode-angle transduction, because the expensive, high-precision angular rotation...

  18. The measurement and interpretation of Ne VII spectral line intensity ratios

    International Nuclear Information System (INIS)

    Lang, J.

    1983-03-01

    Results are presented for the measurement, using the branching ratios calibration method, of the spectral intensities of Ne VII lines emitted from a theta-pinch plasma whose electron temperature and density have been found by laser scattering and alternate techniques. (author)

  19. On a low intensity 241 Am Compton spectrometer for measurement ...

    Indian Academy of Sciences (India)

    In this paper, a new design and construction of a low intensity (100 mCi) 241Am -ray Compton spectrometer is presented. The planar spectrometer is based on a small disc source with the shortest geometry. Measurement of the momentum density of polycrystalline Al is used to evaluate the performance of the new design.

  20. Simulation and Efficient Measurements of Intensities for Complex Imaging Sequences

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Rasmussen, Morten Fischer; Stuart, Matthias Bo

    2014-01-01

    on the sequence to simulate both intensity and mechanical index (MI) according to FDA rules. A 3 MHz BK Medical 8820e convex array transducer is used with the SARUS scanner. An Onda HFL-0400 hydrophone and the Onda AIMS III system measures the pressure field for three imaging schemes: a fixed focus, single...

  1. A study on magnetic relaxation times of various organs and body fluids using superconducting magnetic resonance imaging system part I: measurement of relative signal intensity and T2 relaxation time in various portions of brain and cerebrospinal fluid

    International Nuclear Information System (INIS)

    Chang, Kee Hyun; Lee, Ghi Jai; Han, Moon Hee; Kim, Jae Ho; Han, Man Chang; Kim, Chu Wan

    1988-01-01

    This study was undertake to determine if routine clinical magnetic resonance imaging sequences using only two different repetition times (TRs) and with only two sequential echo times (TEs) can be used to measure reproducible relative signal intensity and T2 relaxation time for normal brain tissues and cerebrospinal fluid using a 2.0T superconducting system. In 47 patients 6 different anatomic sites were measured. For each anatomic location, the mean and standard deviation of these values were determined. On T1-weighted (SE 500msec/30msec) images, in globus pallidus and thalamus, of the CSF, cortical gray matter and retrobulbar fat tissue varied more, with a standard deviation of 11-14% on T1-weighted images. On T2-weighted (SE 3000msec/30msec and 3000msec/80msec) images, the relative signal intensity of all anatomic regions varied more than on T1-weighted images. The standard deviation of T2 relaxation times also varied from 10% (fat tissue) to 18% (CSF). These variations might be due to partial volume averaging, signal alteration of CSF secondary to CSF pulsatile motion, etc. Knowing that relative signal intensity and T2 relaxation times calculated from routine imaging sequences are reproducible in only limited area, these normal ranges can be used to investigate changes occurring in disease states of the limited regions.

  2. Temporal and Latitudinal Variations of the Length-Scales and Relative Intensities of the Chromospheric Network

    Science.gov (United States)

    Raju, K. P.

    2018-05-01

    The Calcium K spectroheliograms of the Sun from Kodaikanal have a data span of about 100 years and covers over 9 solar cycles. The Ca line is a strong chromospheric line dominated by chromospheric network and plages which are good indicators of solar activity. Length-scales and relative intensities of the chromospheric network have been obtained in the solar latitudes from 50 degree N to 50 degree S from the spectroheliograms. The length-scale was obtained from the half-width of the two-dimensional autocorrelation of the latitude strip which gives a measure of the width of the network boundary. As reported earlier for the transition region extreme ultraviolet (EUV) network, relative intensity and width of the chromospheric network boundary are found to be dependent on the solar cycle. A varying phase difference has been noticed in the quantities in different solar latitudes. A cross-correlation analysis of the quantities from other latitudes with ±30 degree latitude revealed an interesting phase difference pattern indicating flux transfer. Evidence of equatorward flux transfer has been observed. The average equatorward flux transfer was estimated to be 5.8 ms-1. The possible reasons of the drift could be meridional circulation, torsional oscillations, or the bright point migration. Cross-correlation of intensity and length-scale from the same latitude showed increasing phase difference with increasing latitude. We have also obtained the cross correlation of the quantities across the equator to see the possible phase lags in the two hemispheres. Signatures of lags are seen in the length scales of southern hemisphere near the equatorial latitudes, but no such lags in the intensity are observed. The results have important implications on the flux transfer over the solar surface and hence on the solar activity and dynamo.

  3. Accessing the public MIMIC-II intensive care relational database for clinical research.

    Science.gov (United States)

    Scott, Daniel J; Lee, Joon; Silva, Ikaro; Park, Shinhyuk; Moody, George B; Celi, Leo A; Mark, Roger G

    2013-01-10

    The Multiparameter Intelligent Monitoring in Intensive Care II (MIMIC-II) database is a free, public resource for intensive care research. The database was officially released in 2006, and has attracted a growing number of researchers in academia and industry. We present the two major software tools that facilitate accessing the relational database: the web-based QueryBuilder and a downloadable virtual machine (VM) image. QueryBuilder and the MIMIC-II VM have been developed successfully and are freely available to MIMIC-II users. Simple example SQL queries and the resulting data are presented. Clinical studies pertaining to acute kidney injury and prediction of fluid requirements in the intensive care unit are shown as typical examples of research performed with MIMIC-II. In addition, MIMIC-II has also provided data for annual PhysioNet/Computing in Cardiology Challenges, including the 2012 Challenge "Predicting mortality of ICU Patients". QueryBuilder is a web-based tool that provides easy access to MIMIC-II. For more computationally intensive queries, one can locally install a complete copy of MIMIC-II in a VM. Both publicly available tools provide the MIMIC-II research community with convenient querying interfaces and complement the value of the MIMIC-II relational database.

  4. Design and performance evaluation of a broadband three dimensional acoustic intensity measuring system.

    Science.gov (United States)

    Miah, Khalid H; Hixon, Elmer L

    2010-04-01

    A seven-microphone three dimensional (3D) intensity measuring system has been developed and evaluated for performance for a broad frequency band (200 Hz-6.5 kHz). Six microphones are arranged in a concentric array with one microphone at the center of the probe. The screw adjustable center microphone is the probe reference microphone, and is used for calibrations of the other microphones in the probe. This probe addresses limitations of the traditional two-microphone system in measuring acoustical properties in a 3D space from the one dimensional measurements. This probe also eliminates the need of spacers used in the existing 3D probes for broadband measurements. Diffraction and reflection effects on calibrations due to presence of the microphones and the probe supporting structure are negligible. This seven-microphone probe provided better results in the intensity measurements for the wide frequency band than that of a similar four-microphone array probe.

  5. LHC Beam Instrumentation: Beam Position and Intensity Measurements (1/3)

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    The LHC is equipped with a full suite of sophisticated beam instrumentation which has been essential for rapid commissioning, the safe increase in total stored beam power and the understanding of machine optics and accelerator physics phenomena. These lectures will introduce these systems and comment on their contributions to the various stages of beam operation. They will include details on: the beam position system and its use for real-time global orbit feedback; the beam loss system and its role in machine protection; total and bunch by bunch intensity measurements; tune measurement and feedback; diagnostics for transverse beam size measurements, abort gap monitoring and longitudinal density measurements. Issues and problems encountered along the way will also be discussed together with the prospect for future upgrades.

  6. Time-resolved and temperature tuneable measurements of fluorescent intensity using a smartphone fluorimeter.

    Science.gov (United States)

    Hossain, Md Arafat; Canning, John; Yu, Zhikang; Ast, Sandra; Rutledge, Peter J; Wong, Joseph K-H; Jamalipour, Abbas; Crossley, Maxwell J

    2017-05-30

    A smartphone fluorimeter capable of time-based fluorescence intensity measurements at various temperatures is reported. Excitation is provided by an integrated UV LED (λ ex = 370 nm) and detection obtained using the in-built CMOS camera. A Peltier is integrated to allow measurements of the intensity over T = 10 to 40 °C. All components are controlled using a smartphone battery powered Arduino microcontroller and a customised Android application that allows sequential fluorescence imaging and quantification every δt = 4 seconds. The temperature dependence of fluorescence intensity for four emitters (rhodamine B, rhodamine 6G, 5,10,15,20-tetraphenylporphyrin and 6-(1,4,8,11-tetraazacyclotetradecane)2-ethyl-naphthalimide) are characterised. The normalised fluorescence intensity over time of the latter chemosensor dye complex in the presence of Zn 2+ is observed to accelerate with an increasing rate constant, k = 1.94 min -1 at T = 15 °C and k = 3.64 min -1 at T = 30 °C, approaching a factor of ∼2 with only a change in temperature of ΔT = 15 °C. Thermally tuning these twist and bend associated rates to optimise sensor approaches and device applications is proposed.

  7. Fluctuations of the electron temperature measured by intensity interferometry on the W7-AS stellarator

    International Nuclear Information System (INIS)

    Sattler, S.

    1993-12-01

    Fluctuations of the electron temperature can cause a significant amount of the anomalous electron heat conductivity observed on fusion plasmas, even with relative amplitudes below one per cent. None of the standard diagnostics utilized for measuring the electron temperature in the confinement region of fusion plasmas is provided with sufficient spatial and temporal resolution and the sensitivity for small fluctuation amplitudes. In this work a new diagnostic for the measurement of electron temperature fluctuations in the confinement region of fusion plasmas was developed, built up, tested and successfully applied on the W7-AS Stellarator. Transport relevant fluctuations of the electron temperature can in principle be measured by radiometry of the electron cyclotron emission (ECE), but they might be buried completely in natural fluctuations of the ECE due to the thermal nature of this radiation. Fluctuations with relative amplitudes below one per cent can be measured with a temporal resolution in the μs-range and a spatial resolution of a few cm only with the help of correlation techniques. The intensity interferometry method, developed for radio astronomy, was applied here: two independent but identical radiometers are viewing the same emitting volume along crossed lines of sight. If the angle between the sightlines is chosen above a limiting value, which is determined by the spatial coherence properties of thermal radiation, the thermal noise is uncorrelated while the temperature fluctuations remain correlated. With the help of this technique relative amplitudes below 0.1% are accessible to measurement. (orig.)

  8. Measuring Relational Reasoning

    Science.gov (United States)

    Alexander, Patricia A.; Dumas, Denis; Grossnickle, Emily M.; List, Alexandra; Firetto, Carla M.

    2016-01-01

    Relational reasoning is the foundational cognitive ability to discern meaningful patterns within an informational stream, but its reliable and valid measurement remains problematic. In this investigation, the measurement of relational reasoning unfolded in three stages. Stage 1 entailed the establishment of a research-based conceptualization of…

  9. Associations between objectively measured physical activity intensity in childhood and measures of subclinical cardiovascular disease in adolescence

    DEFF Research Database (Denmark)

    Ried-Larsen, Mathias; Grøntved, Anders; Møller, Niels Christian

    2014-01-01

    BACKGROUND AND AIM: No prospective studies have investigated the association between physical activity (PA) and carotid subclinical cardiovascular disease across childhood. Therefore, the primary aim was to investigate the association between PA intensity across childhood and carotid intima media......-and-vigorous and vigorous PA intensity were measured using the Actigraph activity monitor. Subclinical cardiovascular disease was expressed as cIMT, carotid arterial stiffness and secondarily as a metabolic risk z-score including the homoeostasis model assessment score of insulin resistance, triglycerides, total......-and-vigorous nor vigorous) nor mean minutes of moderate-and-vigorous PA intensity was associated to the metabolic risk z-score in adolescence (p>0.05). However, a significant inverse association was observed between mean minutes of vigorous PA and the metabolic risk z-score in adolescence independent of gender...

  10. Catheter Related Blood Stream Infections In Patients Of The Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Ana Carolina Coimbra de Castro

    2017-07-01

    Full Text Available Objective: To identify the prevalence of bloodstream infection associated with the Catheter related Blood stream infections in patients of the Intensive Care Unit, and the characteristics of its use and handling. Methods: Descriptive and transversal study with a sample of 88 participants. Data were collected through the observational method and the records in the medical records. The absolute and relative frequencies were used for data analysis. Results: 73.86% of the patients had central venous access in the subclavian vein, 100% used double lumen Catheter related Blood stream infections, 0.5% chlorhexidine solution for skin antisepsis, dressing coverage is performed mostly with Sterile gauze and tape, with a daily exchange. The rate of infection related to the use of the Catheter related Blood stream infections was (6.81%. The most infused pharmacological drugs were antimicrobials (69.32%. Conclusion: The study showed that care with central venous accesses is performed according to recommendations for prevention of bloodstream infection related to the use of these devices. The infection rate is close to the standards found in the literature. Key words: Central Venous Catheterization. Hospital Infection. Intensive care unit. Risk factors. Catheter-Related Infection..

  11. Measurement of natural background radiation intensity on a train

    International Nuclear Information System (INIS)

    Chen, Y. F.; Lin, J. W.; Sheu, R. J.; Lin, U. T.; Jiang, S. H.

    2011-01-01

    This work aims to measure different components of natural background radiation on a train. A radiation measurement system consisting of four types of radiation detectors, namely, a Berkeley Lab cosmic-ray detector, moderated 3He detector, high pressure ionisation chamber and NaI(Tl) spectrometer, associated with a global positioning system unit was established for this purpose. For the commissioning of the system, a test measurement on a train along the railway around the northern Taiwan coast from Hsinchu to Hualien with a distance of ∼275 km was carried out. No significant variation of the intensities of the different components of natural background radiation was observed, except when the train went underground or in the tunnels. The average external dose rate received by the crew of the train was estimated to be 62 nSv h -1 . (authors)

  12. MEASUREMENT OF ENDOTRACHEAL TUBE CUFF PRESSURE IN MECHANICALLYVENTILATED PATIENTS ON ARRIVAL TO INTENSIVE CARE UNIT - A CROSS-SECTIONAL STUDY

    Directory of Open Access Journals (Sweden)

    Arun Kumar Ajjappa

    2017-04-01

    Full Text Available BACKGROUND The monitoring of Endotracheal Tube (ETT cuff pressure in intubated patients on arrival to intensive care unit is very essential. The cuff pressure must be within an optimal range of 20-30cm H2O ensuring ventilation with no complications related to cuff overinflation and underinflation. This can be measured with a cuff pressure manometer. The aim of the study is to measure the endotracheal tube cuff pressure in patients on arrival to intensive care unit and to identify prevalence of endotracheal cuff underinflation and overinflation. MATERIALS AND METHODS A cross-sectional study was done on mechanically-ventilated patients who were intubated in casualty (emergency department on arrival to intensive care unit in S.S. Institute of Medical Sciences and Research Centre, Davangere. About 50 critically-ill patients intubated with a high volume, low pressure endotracheal tube were included in the study. An analogue manometer was used to measure the endotracheal tube cuff pressure. It was compared with the recommended level. The settings of mechanical ventilation, endotracheal tube size and peak airway pressure were recorded. RESULTS It was found that the mean cuff pressure was 64.10 cm of H2O with a standard deviation of 32.049. Of the measured cuff pressures, only 2% had pressures within an optimal range (20-30cm of H2O. 88% had cuff pressures more than 30cm of H2O. The mean peak airway pressure found to be 20.50cm of H2O with a Standard Deviation (SD of 5.064. CONCLUSION This study is done to emphasise the importance of cuff pressure measurement in all mechanically-ventilated patients as cuff pressure is found to be high in most of the patients admitted to intensive care unit. Complications of overinflation and underinflation can only be prevented if the acceptable cuff pressures are achieved.

  13. Relative intensity of bilateral trade flows, regional integration, and trade performance: the case of Brazil, 1984-1998

    Directory of Open Access Journals (Sweden)

    Silva Valquiria da

    2003-01-01

    Full Text Available The objective of this research is to identify the component of trade that results specifically from bilateral relations and evaluate how the creation of trading blocs affects trade relations between countries. The trirapport coefficient of the relative intensity of bilateral agricultural sector trade flows between Brazil and other countries from 1984 and 1998 is used in the evaluation. In general, the results show that relative trade intensity between Brazil and its non-MERCOSUL trade partners fell after their entry into regional trade agreements (extra-bloc effect. The intra-bloc effect (trade expansion is reflected by changes in trade intensity between Brazil and the other MERCOSUL members and changes in trade intensity between NAFTA members Mexico, Canada, and the United States.

  14. Numerical modelling of the pump-to-signal relative intensity noise ...

    Indian Academy of Sciences (India)

    An accurate numerical model to investigate the pump-to-signal relative intensity noise (RIN) transfer in two-pump fibre optical parametric amplifiers (2-P FOPAs) for low modulation frequencies is presented. Compared to other models in the field, this model takes into account the fibre loss, pump depletion as well as the gain ...

  15. Causal relations between knowledge-intensive business services and regional employment growth

    NARCIS (Netherlands)

    Brenner, T.; Capasso, M.; Duschl, M.; Frenken, K.; Treibich, T.G.

    2015-01-01

    This paper studies the causal relations between regional employment growth in Knowledge-Intensive Business Services (KIBS) and overall regional employment growth using German labour-market data for the period 1999-2012. Adopting a recently developed technique, we are able to estimate a structural

  16. Non-intercepting beam intensity measurements towards pico-ampere. Cryogenic current comparators for FAIR

    Energy Technology Data Exchange (ETDEWEB)

    Kurian, Febin [GSI Helmholtzzentrum fuer Schwerionenforschung (Germany); Goethe University, Frankfurt am Main (Germany); Helmholtz Institute Jena (Germany); Schwickert, Marcus; Sieber, Thomas; Kowina, Piotr; Reeg, Hansjoerg [GSI Helmholtzzentrum fuer Schwerionenforschung (Germany); Geithner, Rene; Neubert, Ralf; Seidel, Paul; Golm, Jessica [Friedrich-Schiller-Universitaet Jena (Germany); Stoehlker, Thomas [GSI Helmholtzzentrum fuer Schwerionenforschung (Germany); Helmholtz Institute Jena (Germany); Friedrich-Schiller-Universitaet Jena (Germany)

    2016-07-01

    To satisfy the requirement of non-interceptive measurement of beam intensity down to nA range foreseen in the upcoming FAIR accelerator facility, several Cryogenic Current Comparator (CCC) systems are planned to be installed in its beam transfer lines and storage rings. As a test bench for the development of advanced CCC systems for these installations, the existing CCC system at GSI has been recommissioned and upgraded with advanced sensor components. Successful beam intensity measurements using this upgraded CCC system will be reported in this contribution. Apart from the beam measurements, several operational aspects of the CCC system were investigated, such as the baseline drifts and various noise influences. Combining the operational experiences and boundary conditions given at various installation locations in the FAIR facility, an advanced CCC system is currently under development and is planned to be installed at the Cryring facility at GSI for test measurements. Details on the development of this advanced CCC system will also be presented in this contribution.

  17. A thermal technique for local ultrasound intensity measurement: part 2. Application to exposimetry on a medical diagnostic device

    International Nuclear Information System (INIS)

    Wilkens, V

    2010-01-01

    Acoustic output measurements on medical ultrasound equipment are usually performed using radiation force balances to determine the output power and using hydrophones to determine pressure and intensity parameters. The local temporal-average ultrasound intensity can be measured alternatively by thermal sensors. The technique was described and prototype sensors were characterized in a preceding paper. Here, the application of such a thermal intensity sensor to the output beam characterization of a typical medical diagnostic device is described. Two transducers, a 7.5 MHz linear array and a 3.5 MHz convex array were investigated in different operating modes. For comparison, hydrophone measurements were also performed. If the spatial averaging effect is taken into account, good agreement is found between both measurement methods. The maximum deviations of the spatial-peak temporal-average intensities I SPTA obtained with the thermal sensor from the corresponding hydrophone-based results were below 12%. The simple thermal technique offers advantages for intensity measurements especially in the case of scanning and combined modes of the diagnostic device, where the synchronization between hydrophone measurements and the complex pulse emission pattern can be difficult

  18. Clinical Competence and Its Related Factors of Nurses in Neonatal Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Jila Mirlashari

    2016-12-01

    Full Text Available Introduction: Clinical competence of nurses working in the neonatal intensive care units together with advancements in medical science and technology increased the survival rate of newborns that need specialized care. To ensure the quality of care and provide the safety of patients, evaluating the clinical competence of nurses seems necessary. This study aimed to evaluate the clinical competence of nurses in the neonatal intensive care units. Methods: In this cross-sectional study, 117 nurses working in the neonatal intensive care units of the hospitals affiliated to Tehran University of Medical Sciences were selected by census method. The research tool was Development of Competency Inventory for Registered Nurses questionnaire which completed by self-assessment. The mean clinical competence scores of participants categorized into 3 levels: weak: 273. Data were analyzed by SPSS version 13 using the Pearson correlation coefficient, t-test and Chi-square test. Results: The highest levels of competence were related to critical thinking and research attitude and interpersonal relationships, and the lowest level was related to training and mentoring. There was a direct statistically significant relationship between marital status, employment status, level of interest in working in the neonatal intensive-care units and the clinical competence of nurses. Conclusion: Since the clinical competence of nurses in the Neonatal Intensive Care Units is vital, some variables such as interest in the nursing profession, employment status, the neonatal intensive theoretical and practical training courses and the amount of overtime working hours should be taken into consideration.

  19. Measurement of the profile and intensity of the solar He I lambda 584-A resonance line

    Science.gov (United States)

    Maloy, J. O.; Hartmann, U. G.; Judge, D. L.; Carlson, R. W.

    1978-01-01

    The intensity and profile of the helium resonance line at 584 A from the entire disk of the sun was investigated by using a rocket-borne helium-filled spectrometer and a curve-of-growth technique. The line profile was found to be accurately represented by a Gaussian profile with full width at half maximum of 122 + or - 10 mA, while the integrated intensity was measured to be 2.6 + or - 1.3 billion photons/s per sq cm at solar activity levels of F(10.7) = 90.8 x 10 to the -22nd per sq m/Hz and Rz = 27. The measured line width is in good agreement with previous spectrographic measurements, but the integrated intensity is larger than most previous photoelectric measurements. However, the derived line center flux of 20 + or - 10 billion photons/s per sq cm/A is in good agreement with values inferred from airglow measurements.

  20. The relation between intensity and complexity of coronary artery lesion and oxidative stress in patients with acute coronary syndrome.

    Science.gov (United States)

    Turan, Turhan; Menteşe, Ümit; Ağaç, Mustafa Tarık; Akyüz, Ali Rıza; Kul, Selim; Aykan, Ahmet Çağrı; Bektaş, Hüseyin; Korkmaz, Levent; Öztaş Menteşe, Seda; Dursun, İhsan; Çelik, Şükrü

    2015-10-01

    Oxidative stress plays a major role in the development of atherosclerosis. However, the relationship between oxidative stress and complexity and intensity of coronary artery disease is less clear. The aim of this study is to assess the relationship between oxidative stress markers and the complexity and intensity of coronary artery disease in patients with acute coronary syndrome (ACS). Sixty-seven consecutive patients with an early phase of ACS (=22). Likewise patients were divided into two CAD severity groups according to the median Gensini score of 64: less intensive CAD with Gensini score (=64. Blood samples were taken in 1 hour within administration in order to measure total oxidative status (TOS) and total antioxidant capacity (TAC) levels determined by Erel method. Oxidative stress index (OSI) was calculated by TOS /TAC. There was no significant difference between the two SYNTAX groups for oxidative stress markers. Median TOS and OSI values were significantly high in the intensive CAD group (p=0.005, p=0.04, respectively). The Gensini score was positively correlated with TOS and OSI (p=0.003, p=0.02, respectively). Oxidative stress markers may be considered supportive laboratory parameters related to CAD intensity but not complexity in ACS patients.

  1. On calculating intensity from XPS spectra

    International Nuclear Information System (INIS)

    Vegh, Janos

    2006-01-01

    The intensity calculation is the basis for all quantitative applications of electron spectroscopy. Unfortunately, some misinterpreted terms are used and correctly interpreted terms are misused in the overwhelming majority of publications in XPS, including most textbooks as well as accepted and proposed standards. Due to this mistake the number of the detected electrons is given as having dimension of energy (?) and also the formulas for calculating the peak area and its standard deviation are wrong. Since in all other spectroscopic fields the number of the detected particles is dimensionless, continuing this practice leads to isolating XPS from both other measurement sciences and theory, because the measured total intensity in XPS is simply not comparable to the ones derived with other spectroscopic methods or theoretically. Therefore, the basic measuring processes and terms are critically reviewed and their physically correct interpretation is given. This interpretation reveals that the error is hidden in the incorrect interpretation of both the measurement process and the measured quantity. It is shown that through using the correct interpretation both the dimensions of the intensity calculated from electron spectroscopic measurements as well as the formulas related to the intensity and its standard deviation will agree with all other spectroscopic fields

  2. Measurement of extent of intense ion beam charge neutralization

    Energy Technology Data Exchange (ETDEWEB)

    Engelko, V [Efremov Institute of Electrophysical Apparatus, St. Petersburg (Russian Federation); Giese, H; Schalk, S [Forschungszentrum Karlsruhe (Germany). INR

    1997-12-31

    Various diagnostic tools were employed to study and optimize the extent of space charge neutralization in the pulsed intense proton beam facility PROFA, comprising Langmuir probes, capacitive probes, and a novel type of the three electrode collector. The latter does not only allow us to measure ion and electron beam current densities in a high magnetic field environment, but also to deduce the density spectrum of the beam electrons. Appropriate operating conditions were identified to attain a complete space charge neutralisation. (author). 5 figs., 4 refs.

  3. Measurement of solar ultraviolet radiation intensity type A and B in Qazvin (2013-14

    Directory of Open Access Journals (Sweden)

    SAR. Babaee

    2016-08-01

    Full Text Available Background: Solar ultraviolet radiation (UVR is considered one of the most important biological risk factors in the world. Most health damages from solar ultraviolet radiation at ground level are mainly caused by UVA and UVB spectrums. Objective: The aim of this study was to Measure the solar ultraviolet radiation intensity type A and B in Qazvin city. Methods: In this cross-sectional study, the intensity of solar ultraviolet radiation type A and B was measured in Qazvin on years of 2013-14 (during one year every monthly at three times, in the morning, afternoon and evening by using a UV Radiometer. Data were analyzed using descriptive statistics. Findings: The maximum average intensity of UVA and UVB rays during the one year with 28.36±1.88 W/m2 and 0.156±0.035 W/m2 respectively was in Tir month (June 22–July 22 and the minimum average intensity of UVA and UVB rays with 10.36±0.83 W/m2 and 0.041±0.010 W/m2 respectively was in Dai month (December 22–January 20. Conclusion: With regards to the results, it is recommended that individuals were less exposed to exposure time with direct sunshine and use appropriate protective measures such as; wear appropriate clothing, sunglasses, and sunscreen.

  4. Measurement accuracy of weighing and tipping-bucket rainfall intensity gauges under dynamic laboratory testing

    Science.gov (United States)

    Colli, M.; Lanza, L. G.; La Barbera, P.; Chan, P. W.

    2014-07-01

    The contribution of any single uncertainty factor in the resulting performance of infield rain gauge measurements still has to be comprehensively assessed due to the high number of real world error sources involved, such as the intrinsic variability of rainfall intensity (RI), wind effects, wetting losses, the ambient temperature, etc. In recent years the World Meteorological Organization (WMO) addressed these issues by fostering dedicated investigations, which revealed further difficulties in assessing the actual reference rainfall intensity in the field. This work reports on an extensive assessment of the OTT Pluvio2 weighing gauge accuracy when measuring rainfall intensity under laboratory dynamic conditions (time varying reference flow rates). The results obtained from the weighing rain gauge (WG) were also compared with a MTX tipping-bucket rain gauge (TBR) under the same test conditions. Tests were carried out by simulating various artificial precipitation events, with unsteady rainfall intensity, using a suitable dynamic rainfall generator. Real world rainfall data measured by an Ogawa catching-type drop counter at a field test site located within the Hong Kong International Airport (HKIA) were used as a reference for the artificial rain generation system. Results demonstrate that the differences observed between the laboratory and field performance of catching-type gauges are only partially attributable to the weather and operational conditions in the field. The dynamics of real world precipitation events is responsible for a large part of the measurement errors, which can be accurately assessed in the laboratory under controlled environmental conditions. This allows for new testing methodologies and the development of instruments with enhanced performance in the field.

  5. Measuring Pancharatnam's relative phase for SO(3) evolutions using spin polarimetry

    International Nuclear Information System (INIS)

    Larsson, Peter; Sjoeqvist, Erik

    2003-01-01

    In polarimetry, a superposition of internal quantal states is exposed to a single Hamiltonian and information about the evolution of the quantal states is inferred from projection measurements on the final superposition. In this framework, we here extend the polarimetric test of Pancharatnam's relative phase for spin-(1/2) proposed by Wagh and Rakhecha [Phys. Lett. A 197, 112 (1995)] to spin j≥1 undergoing noncyclic SO(3) evolution. We demonstrate that the output intensity for higher spin values is a polynomial function of the corresponding spin-(1/2) intensity. We further propose a general method to extract the noncyclic SO(3) phase and visibility by rigid translation of two π/2 spin flippers. Polarimetry on higher spin states may in practice be done with spin polarized atomic beams

  6. Measurement of rain intensity by means of active-passive remote sensing

    Science.gov (United States)

    Linkova, Anna; Khlopov, Grygoriy

    2014-05-01

    Measurement of rain intensity is of great interest for municipal services and agriculture, particularly because of increasing number of floods and landslides. At that monitoring of amount of liquid precipitation allows to schedule work of hydrological services to inform the relevant public authorities about violent weather in time. That is why development of remote sensing methods for monitoring of rains is quite important task. The inverse problem solution of rain remote sensing is based on the measurements of scattering or radiation characteristics of rain drops. However liquid precipitation has a difficult structure which depends on many parameters. So using only scattering or radiation characteristics obtained by active and passive sensing at a single frequency does not allow to solve the inverse problem. Therefore double frequency sensing is widely used now for precipitation monitoring. Measurement of reflected power at two frequencies allows to find two parameters of drop size distribution of rain drops. However three-parameter distributions (for example gamma distribution) are the most prevalent now as a rain model, so in this case solution of the inverse problem requires the measurement of at least three uncorrelated variables. That is why a priori statistical meteorological data obtained by contact methods are used additionally to the double frequency sensing to solve the inverse problem. In particular, authors proposed and studied the combined method of double frequency sensing of rains based on dependence of the parameters of gamma distribution on rain intensity. The numerical simulation and experimental study shown that the proposed method allows to retrieve the profile of microstructure and integral parameters of rain with accuracy less than 15%. However, the effectiveness of the proposed method essentially depends on the reliability of the used statistical data which are tend to have a strong seasonal and regional variability led to significant

  7. Measurement of angular distributions of K x-ray intensity of Ti and Cu thick targets following impact of 10–25 keV electrons

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Bhupendra; Kumar, Sunil; Prajapati, Suman; Singh, Bhartendu K. [Atomic Physics Laboratory, Department of Physics, Institute of Science, Banaras Hindu University, Varanasi 221005 (India); Llovet, Xavier [Scientific and Technological Centers, Universitat de Barcelona, Lluís Solé i Sabarís 1-3, 08028 Barcelona (Spain); Shanker, R., E-mail: shankerorama@gmail.com [Atomic Physics Laboratory, Department of Physics, Institute of Science, Banaras Hindu University, Varanasi 221005 (India)

    2017-04-15

    Highlights: • New results on the angular distributions of relative intensities of K-X-rays lines of Ti and Cu thick targets under electron bombardment are reported. • An increase of relative intensity of Kα and Kβ X-ray lines has been found to be about 60–70% in the detection range θ = 105{sup 0}–165{sup 0}. • There is a slight impact energy dependence of Cu Kα X-ray line. • A reasonable agreement between experimental and PENELOPE MC Calculations are obtained. - Abstract: We present new results on angular distributions of the relative intensity of K{sub α} and K{sub β} x-ray lines of thick targets of Ti (Z = 22) and Cu (Z = 29) pure elements following impact of 10–25 keV electrons. The angular measurements of the K x-radiations were accomplished by rotating the target surface with respect to the electron beam direction. The x-rays emerging from the target surface in reflection mode were detected by an energy dispersive Si P-I-N photodiode detector. The resulting variation of the relative intensity of the characteristic lines as a function of angle of detection and impact energy has been found to be anisotropic and it is considered to arise due to change in path lengths at a given incidence angle α for the photons generated by direct as well as by indirect K shell ionization processes. The measured angular variations of relative intensity of K{sub α} and K{sub β} x-ray lines of both targets are found to increase by about 60–70% in going from θ = 105{sup 0} to 165{sup 0} at a given impact energy; however there is a slight indication of impact energy dependence of Cu K{sub α} x-ray line as also noted by the earlier workers. We compare the experimental results with those obtained by Monte Carlo simulations using PENELOPE calculations; the agreement between experiment and theory is found to be satisfactory within uncertainties involved in the measurements and the theoretical results.

  8. Exploring Shared Measurement Properties and Score Comparability between Two Versions of the "Supports Intensity Scale"

    Science.gov (United States)

    Seo, Hyojeong; Shogren, Karrie A.; Wehmeyer, Michael L.; Hughes, Carolyn; Thompson, James R.; Little, Todd D.; Palmer, Susan B.

    2016-01-01

    This study examined similarities and differences in measurement properties and score comparability of the "Supports Intensity Scale-Adult Version" (16-64 years) and the "Supports Intensity Scale-Children's Version" (5-16 years). Data were collected from 142 adolescents with intellectual disability with both versions of the…

  9. Transverse Beam Halo Measurements at High Intensity Neutrino Source (HINS) using Vibrating Wire Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, M.; Hanna, B.; Scarpine, V.; Shiltsev, V.; Steimel, J.; Artinian, S.; Arutunian, S.

    2015-02-26

    The measurement and control of beam halos will be critical for the applications of future high-intensity hadron linacs. In particular, beam profile monitors require a very high dynamic range when used for the transverse beam halo measurements. In this study, the Vibrating Wire Monitor (VWM) with aperture 60 mm was installed at the High Intensity Neutrino Source (HINS) front-end to measure the transverse beam halo. A vibrating wire is excited at its resonance frequency with the help of a magnetic feedback loop, and the vibrating and sensitive wires are connected through a balanced arm. The sensitive wire is moved into the beam halo region by a stepper motor controlled translational stage. We study the feasibility of the vibrating wire for the transverse beam halo measurements in the low-energy front-end of the proton linac.

  10. Obstetric patients' health-related quality of life before and after intensive care.

    Science.gov (United States)

    Pia, Seppänen; Reijo, Sund; Tero, Ala-Kokko; Mervi, Roos; Jukka, Uotila; Mika, Helminen; Tarja, Suominen

    2018-03-23

    Intensive care admissions during pregnancy, childbirth, and postpartum period are relatively well investigated. However, very little is known about these obstetric patients' health-related quality of life (HRQoL) before and after critical care. The objective of this study was to assess obstetric patients' HRQoL before intensive care admission (baseline) and at 6 months after discharge (follow-up) DESIGN: This was a retrospective database study. In a 5-year period, the data of all women admitted to the intensive care unit (ICU) during pregnancy, delivery, or up to 42 days postpartum were analysed. Four multidisciplinary ICUs of Finnish University hospitals participated. The HRQoL was assessed using the EuroQol-5D (EQ-5D) instrument with utility score (EQsum) and visual analogue scale (EQ-VAS). A total of 283 obstetric patients were identified from the clinical information system. Of these, 99 (35%) completed the EQ-5D questionnaires both at baseline and follow-up, and 65 of them (23%) completed EQ-VAS. The comparison of patients' EQsum scores before intensive care admission and after discharge showed that patients' HRQoL remained good (0.970 vs 0.972) (max 1.0) or increased (0.788 vs 0.982) in 80.8% of the patients. Patients reported improved overall health on the EQ-VAS at 6 months follow-up (EQ-VAS mean, 71.86 vs 88.20; p ≤ 0.001) (max 100). However, 19.2% of the patients had lower HRQoL (EQsum mean 0.987 vs 0.798) at follow-up. Following intensive care, 15% of the patients had more pain/discomfort, and 11% expressed more depression/anxiety. Multiparous patients were more likely to suffer from worsened depression/anxiety (p = 0.024). In the majority of the obstetric patients, HRQoL at 6 months follow-up remained good or had increased from baseline. However, nearly one-fifth of the patients had impaired HRQoL after discharge. Thus, intensive care management should take in to consideration follow-up program after intensive care of ICU-admitted obstetric

  11. Design of a Thermoacoustic Sensor for Low Intensity Ultrasound Measurements Based on an Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Jida Xing

    2015-06-01

    Full Text Available In therapeutic ultrasound applications, accurate ultrasound output intensities are crucial because the physiological effects of therapeutic ultrasound are very sensitive to the intensity and duration of these applications. Although radiation force balance is a benchmark technique for measuring ultrasound intensity and power, it is costly, difficult to operate, and compromised by noise vibration. To overcome these limitations, the development of a low-cost, easy to operate, and vibration-resistant alternative device is necessary for rapid ultrasound intensity measurement. Therefore, we proposed and validated a novel two-layer thermoacoustic sensor using an artificial neural network technique to accurately measure low ultrasound intensities between 30 and 120 mW/cm2. The first layer of the sensor design is a cylindrical absorber made of plexiglass, followed by a second layer composed of polyurethane rubber with a high attenuation coefficient to absorb extra ultrasound energy. The sensor determined ultrasound intensities according to a temperature elevation induced by heat converted from incident acoustic energy. Compared with our previous one-layer sensor design, the new two-layer sensor enhanced the ultrasound absorption efficiency to provide more rapid and reliable measurements. Using a three-dimensional model in the K-wave toolbox, our simulation of the ultrasound propagation process demonstrated that the two-layer design is more efficient than the single layer design. We also integrated an artificial neural network algorithm to compensate for the large measurement offset. After obtaining multiple parameters of the sensor characteristics through calibration, the artificial neural network is built to correct temperature drifts and increase the reliability of our thermoacoustic measurements through iterative training about ten seconds. The performance of the artificial neural network method was validated through a series of experiments. Compared

  12. Design of a Thermoacoustic Sensor for Low Intensity Ultrasound Measurements Based on an Artificial Neural Network.

    Science.gov (United States)

    Xing, Jida; Chen, Jie

    2015-06-23

    In therapeutic ultrasound applications, accurate ultrasound output intensities are crucial because the physiological effects of therapeutic ultrasound are very sensitive to the intensity and duration of these applications. Although radiation force balance is a benchmark technique for measuring ultrasound intensity and power, it is costly, difficult to operate, and compromised by noise vibration. To overcome these limitations, the development of a low-cost, easy to operate, and vibration-resistant alternative device is necessary for rapid ultrasound intensity measurement. Therefore, we proposed and validated a novel two-layer thermoacoustic sensor using an artificial neural network technique to accurately measure low ultrasound intensities between 30 and 120 mW/cm2. The first layer of the sensor design is a cylindrical absorber made of plexiglass, followed by a second layer composed of polyurethane rubber with a high attenuation coefficient to absorb extra ultrasound energy. The sensor determined ultrasound intensities according to a temperature elevation induced by heat converted from incident acoustic energy. Compared with our previous one-layer sensor design, the new two-layer sensor enhanced the ultrasound absorption efficiency to provide more rapid and reliable measurements. Using a three-dimensional model in the K-wave toolbox, our simulation of the ultrasound propagation process demonstrated that the two-layer design is more efficient than the single layer design. We also integrated an artificial neural network algorithm to compensate for the large measurement offset. After obtaining multiple parameters of the sensor characteristics through calibration, the artificial neural network is built to correct temperature drifts and increase the reliability of our thermoacoustic measurements through iterative training about ten seconds. The performance of the artificial neural network method was validated through a series of experiments. Compared to our previous

  13. Description and operation of the LEDA beam-position/intensity measurement module

    International Nuclear Information System (INIS)

    Rose, C.R.; Stettler, M.W.

    1997-01-01

    This paper describes the specification, design and preliminary operation of the beam-position/intensity measurement module being built for the Low Energy Demonstration Accelerator (LEDA) and Accelerator Production of Tritium (APT) projects at Los Alamos National Laboratory. The module, based on the VXI footprint, is divided into three sections: first, the analog front-end which consists of logarithmic amplifiers, anti-alias filters, and digitizers; second, the digital-to-analog section for monitoring signals on the front panel; and third, the DSP, error correction, and VXI-interface section. Beam position is calculated based on the log-ratio transfer function. The module has four, 2-MHz, IF inputs suitable for two-axis position measurements. It has outputs in both digital and analog format for x- and y-position and beam intensity. Real-time error-correction is performed on the four input signals after they are digitized and before calculating the beam position to compensate for drift, offsets, gain non-linearities, and other systematic errors. This paper also describes how the on-line error-correction is implemented digitally and algorithmically

  14. Radiation Dose Measurement for High-Intensity Laser Interactions with Solid Targets at SLAC

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Taiee [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-09-25

    A systematic study of photon and neutron radiation doses generated in high-intensity laser-solid interactions is underway at SLAC National Accelerator Laboratory. We found that these laser-solid experiments are being performed using a 25 TW (up to 1 J in 40 fs) femtosecond pulsed Ti:sapphire laser at the Linac Coherent Light Source’s (LCLS) Matter in Extreme Conditions (MEC) facility. Additionally, radiation measurements were performed with passive and active detectors deployed at various locations inside and outside the target chamber. Results from radiation dose measurements for laser-solid experiments at SLAC MEC in 2014 with peak intensity between 1018 to 7.1x1019 W/cm2 are presented.

  15. Neural processing of emotional-intensity predicts emotion regulation choice.

    Science.gov (United States)

    Shafir, Roni; Thiruchselvam, Ravi; Suri, Gaurav; Gross, James J; Sheppes, Gal

    2016-12-01

    Emotional-intensity is a core characteristic of affective events that strongly determines how individuals choose to regulate their emotions. Our conceptual framework suggests that in high emotional-intensity situations, individuals prefer to disengage attention using distraction, which can more effectively block highly potent emotional information, as compared with engagement reappraisal, which is preferred in low emotional-intensity. However, existing supporting evidence remains indirect because prior intensity categorization of emotional stimuli was based on subjective measures that are potentially biased and only represent the endpoint of emotional-intensity processing. Accordingly, this study provides the first direct evidence for the role of online emotional-intensity processing in predicting behavioral regulatory-choices. Utilizing the high temporal resolution of event-related potentials, we evaluated online neural processing of stimuli's emotional-intensity (late positive potential, LPP) prior to regulatory-choices between distraction and reappraisal. Results showed that enhanced neural processing of intensity (enhanced LPP amplitudes) uniquely predicted (above subjective measures of intensity) increased tendency to subsequently choose distraction over reappraisal. Additionally, regulatory-choices led to adaptive consequences, demonstrated in finding that actual implementation of distraction relative to reappraisal-choice resulted in stronger attenuation of LPPs and self-reported arousal. © The Author (2016). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  16. Size measurement of radioactive aerosol particles in intense radiation fields using wire screens and imaging plates

    Energy Technology Data Exchange (ETDEWEB)

    Oki, Yuichi; Tanaka, Toru; Takamiya, Koichi; Ishi, Yoshihiro; UesugI, Tomonori; Kuriyama, Yasutoshi; Sakamoto, Masaaki; Ohtsuki, Tsutomu [Kyoto University Research Reactor Institute, Osaka (Japan); Nitta, Shinnosuke [Graduate School of Engineering, Kyoto University, Kyoto (Japan); Osada, Naoyuki [Advanced Science Research Center, Okayama University, Okayama (Japan)

    2016-09-15

    Very fine radiation-induced aerosol particles are produced in intense radiation fields, such as high-intensity accelerator rooms and containment vessels such as those in the Fukushima Daiichi nuclear power plant (FDNPP). Size measurement of the aerosol particles is very important for understanding the behavior of radioactive aerosols released in the FDNPP accident and radiation safety in high-energy accelerators. A combined technique using wire screens and imaging plates was developed for size measurement of fine radioactive aerosol particles smaller than 100 nm in diameter. This technique was applied to the radiation field of a proton accelerator room, in which radioactive atoms produced in air during machine operation are incorporated into radiation-induced aerosol particles. The size of 11C-bearing aerosol particles was analyzed using the wire screen technique in distinction from other positron emitters in combination with a radioactive decay analysis. The size distribution for 11C-bearing aerosol particles was found to be ca. 70 μm in geometric mean diameter. The size was similar to that for 7Be-bearing particles obtained by a Ge detector measurement, and was slightly larger than the number-based size distribution measured with a scanning mobility particle sizer. The particle size measuring method using wire screens and imaging plates was successfully applied to the fine aerosol particles produced in an intense radiation field of a proton accelerator. This technique is applicable to size measurement of radioactive aerosol particles produced in the intense radiation fields of radiation facilities.

  17. Poster - Thurs Eve-09: Evaluation of a commercial 2D ion-chamber array for intensity modulated radiation therapy dose measurements.

    Science.gov (United States)

    Mei, X; Bracken, G; Kerr, A

    2008-07-01

    Experimental verification of calculated dose from a treatment planning system is often essential for quality assurance (QA) of intensity modulated radiation therapy (IMRT). Film dosimetry and single ion chamber measurements are commonly used for IMRT QA. Film dosimetry has very good spatial resolution, but is labor intensive and absolute dose is not reliable. Ion chamber measurements are still required for absolute dose after measurements using films. Dosimeters based on 2D detector arrays that can measure 2D dose in real-time are gaining wider use. These devices provide a much easier and reliable tool for IMRT QA. We report the evaluation of a commercial 2D ion chamber array, including its basic performance characteristics, such as linearity, reproducibility and uniformity of relative ion chamber sensitivities, and comparisons between measured 2D dose and calculated dose with a commercial treatment planning system. Our analysis shows this matrix has excellent linearity and reproducibility, but relative sensitivities are tilted such that the +Y region is over sensitive, while the -Y region is under sensitive. Despite this behavior, our results show good agreement between measured 2D dose profiles and Eclipse planned data for IMRT test plans and a few verification plans for clinical breast field-in-field plans. The gamma values (3% or 3 mm distance-to-agreement) are all less than 1 except for one or two pixels at the field edge This device provides a fast and reliable stand-alone dosimeter for IMRT QA. © 2008 American Association of Physicists in Medicine.

  18. Implementation of the Electronics Chain for the Bunch by Bunch Intensity Measurement Devices for the LHC

    CERN Document Server

    Belohrad, D; Ludwig, M; Savioz, J J; Thoulet, S

    2009-01-01

    The fast beam intensity measurements for the LHC are provided by eight Fast Beam Current Transformers (FBCT). Four FBCTs installed in the LHC rings are capable of providing both bunch-by-bunch and total turn-by-turn beam intensity information. A further four FBCTs, two in each of the LHC dump lines, are used to measure the total extracted beam intensity. In addition to providing intensity information the ring FBCTs also send signals to the machine protection system. This increases the complexity of both the RF front-end and the digital acquisition parts of the signal processing chain. The aim of this paper is to discuss the implemented hardware solution for the FBCT system, in particular with respect to the signal distribution, FPGA signal processing, calibration, and interaction of the FBCTs with the machine protection chain.

  19. Density and potential measurements in an intense ion-beam-generated plasma

    International Nuclear Information System (INIS)

    Abt, N.E.

    1982-05-01

    Neutral beams are created by intense large area ion beams which are neutralized in a gas cell. The interaction of the beam with the gas cell creates a plasma. Such a plasma is studied here. The basic plasma parameters, electron temperature, density, and plasma potential, are measured as a function of beam current and neutral gas pressure. These measurements are compared to a model based on the solution of Poisson's equation. Because of the cylindrical geometry the equation cannot be solved analytically. Details of the numerical method are presented

  20. Optical Spectroscopy Measurements of Shock Waves Driven by Intense Z-Pinch Radiation

    International Nuclear Information System (INIS)

    Asay, J.; Bernard, M.; Bailey, J.E.; Carlson, A.L.; Chandler, G.A.; Hall, C.A.; Hanson, D.; Johnston, R.; Lake, P.; Lawrence, J.

    1999-01-01

    Z-pinches created using the Z accelerator generate approximately220 TW, 1.7 MJ radiation pulses that heat large (approximately10 cm 3 ) hohlraums to 100-150 eV temperatures for times of order 10 nsec. We are performing experiments exploiting this intense radiation to drive shock waves for equation of state studies. The shock pressures are typically 1-10 Mbar with 10 nsec duration in 6-mm-diameter samples. In this paper we demonstrate the ability to perform optical spectroscopy measurements on shocked samples located in close proximity to the z-pinch. These experiments are particularly well suited to optical spectroscopy measurements because of the relatively large sample size and long duration. The optical emission is collected using fiber optics and recorded with a streaked spectrograph. Other diagnostics include VISAR and active shock breakout measurements of the shocked sample and a suite of diagnostics that characterize the radiation drive. Our near term goal is to use the spectral emission to obtain the temperature of the shocked material. Longer term objectives include the examination of deviations of the spectrum from blackbody, line emission from lower density regions, determination of kinetic processes in molecular systems, evaluation of phase transitions such as the onset of metalization in transparent materials, and characterization of the plasma formed when the shock exits the rear surface. An initial set of data illustrating both the potential and the challenge of these measurements is described

  1. Accurate Profile Measurement of the low Intensity Secondary Beams in the CERN Experimental Areas

    CERN Document Server

    AUTHOR|(CDS)2084531; Tranquille, Gerard

    2018-02-23

    The CERN accelerators deliver a wide spectrum of secondary beams to the Experimental Areas. These beams are composed of hadrons, leptons, and heavy ions that can vary greatly in momentum (1 GeV/c to 400 GeV/c) and intensity (10^2 to 10^8 particles per second). The profile, position, and intensity of these beams are measured utilising particle detectors. However, the current systems show several problems that limit the quality of this kind of monitoring. The aim of this doctoral thesis is to investigate the best detector technology that could replace the existing monitors and build a first prototype of it. A review of the existing detection techniques has led to the choice of Scintillating Fibres (SciFi) read-out with Silicon Photomultipliers (SiPM). This detection technology has the potential to perform better in terms of material budget, range of intensities measured, and active area size. In addition, it has particle counting capabilities, which could extend its application to momentum spectrometry or Time...

  2. Status Concern and Relative Deprivation in China: Measures, Empirical Evidence and Economic and Policy Implications

    Science.gov (United States)

    Xi, CHEN

    2017-01-01

    Status concern and feelings of relative deprivation affect individual behaviour and well-being. Traditional norms and the alarming inequality in China have made relative deprivation increasingly intense for the Chinese population. This article reviews empirical literature on China that attempts to test the relative deprivation hypothesis, and also reviews the origins and pathways of relative deprivation, compares its economic measures in the literature and summarises the scientific findings. Drawing from solid empirical evidence, the author discusses the important policy implications on redistribution, official regulations and grassroots sanctions, and relative poverty alleviation. PMID:29033479

  3. Technology for Intensive Poultry Production as a Source of Odour Emissions with Time-Varying Intensity

    Directory of Open Access Journals (Sweden)

    Kuneš Radim

    2017-12-01

    Full Text Available The technology for intensive broiler breeding using deep litter method provides convenient conditions for production of odour substances inside the barn. As a consequence, there are relatively high odour emissions in the breeding area and its surrounding, which has significant impacts on the life quality of both people and animals. The amount of produced emissions increases in time because it is closely related to the amount of poultry droppings accumulated in litter inside the barn. This paper deals with changes in odour intensity depending on time measured since the beginning of broiler fattening. Odour intensity was measured by methods of dynamic olfactometry. The estimated values gradually increased from 45 ouE·m-3 to the highest value of 259 ouE·m-3, which was determined in the final fattening phase (broilers’ age 33 days. The calculated odour substances emission values were in range from 0.02 ouE·s-1·bird-1 at the beginning of fattening up to 0.10 ouE·s-1·bird-1 in the final fattening phase. Odour emissions increased five times during the fattening period.

  4. An industrial radiography exposure device based on measurement of transmitted gamma-ray intensity

    International Nuclear Information System (INIS)

    Polee, C; Chankow, N; Srisatit, S; Thong-Aram, D

    2015-01-01

    In film radiography, underexposure and overexposure may happen particularly when lacking information of specimen material and hollowness. This paper describes a method and a device for determining exposure in industrial gamma-ray radiography based on quick measurement of transmitted gamma-ray intensity with a small detector. Application software was developed for Android mobile phone to remotely control the device and to display counting data via Bluetooth communication. Prior to film exposure, the device is placed behind a specimen to measure transmitted intensity which is inversely proportional to the exposure. Unlike in using the conventional exposure curve, correction factors for source decay, source-to- film distance, specimen thickness and kind of material are not needed. The developed technique and device make radiographic process economic, convenient and more reliable. (paper)

  5. Measuring and accounting for the intensity of nursing care: is it worthwhile?

    Science.gov (United States)

    Finkler, Steven A

    2008-05-01

    In June 2007, the Robert Wood Johnson Foundation sponsored a conference titled "The Economics of Nursing: Paying for Quality Nursing Care." The second topic at the conference was "the appropriateness and feasibility of measuring and accounting for the intensity of nursing care." Drs. Welton and Sermeus presented papers on that topic. This response to those papers focuses on why the hospital industry has not always accounted for and measured nursing intensity. Then it asks, "Why do we want more accurate information about nursing resources used by different patients?" It is not sufficient to say the data regarding nursing costs are not accurate. Nor is it sufficient to say that we now can improve the accuracy of the data. To move forward in this area, we need to develop compelling evidence and arguments that indicate that nursing-cost data of greater accuracy have a benefit that will exceed the costs of that data collection.

  6. Measurement of average density and relative volumes in a dispersed two-phase fluid

    Science.gov (United States)

    Sreepada, Sastry R.; Rippel, Robert R.

    1992-01-01

    An apparatus and a method are disclosed for measuring the average density and relative volumes in an essentially transparent, dispersed two-phase fluid. A laser beam with a diameter no greater than 1% of the diameter of the bubbles, droplets, or particles of the dispersed phase is directed onto a diffraction grating. A single-order component of the diffracted beam is directed through the two-phase fluid and its refraction is measured. Preferably, the refracted beam exiting the fluid is incident upon a optical filter with linearly varing optical density and the intensity of the filtered beam is measured. The invention can be combined with other laser-based measurement systems, e.g., laser doppler anemometry.

  7. Memory in relation to depth of sedation in adult mechanically ventilated intensive care patients.

    OpenAIRE

    Samuelson, Karin; Lundberg, Dag; Fridlund, Bengt

    2006-01-01

    Objective: To investigate the relationship between memory and intensive care sedation. Design and setting: Prospective cohort study over 18 months in two general intensive care units (ICUs) in district university hospitals. Patients: 313 intubated mechanically ventilated adults admitted for more than 24 h, 250 of whom completed the study. Measurements: Patients (n = 250) were interviewed in the ward 5 days after discharge from the ICU using the ICU Memory Tool. Patient characteristics, doses ...

  8. Interpretation of intensities in electron-momentum and photoelectron spectroscopies

    International Nuclear Information System (INIS)

    McCarthy, I.E.

    1984-06-01

    Relative intensities for the photoelectron reaction on atoms and molecules are not related to structure calculations in the same way as those for the noncoplanar symmetric (e,2e) reaction. The photoelectron dipole matrix element is dependent on recoil momentum only through its unique relationship to the photon energy and is much harder to calculate for chemically-interesting momenta. Relative intensities for binary (e,2e) reactions are independent of total energy at high enough energies and strongly dependent on symmetry and recoil momentum, for which an intensity profile can be measured for values starting at zero. In comparing with structure calculations, binary (e,2e) intensities for low recoil momentum may be compared directly with pole strengths in calculations of the one-electron Green's function or corresponding configuration-interaction calculations. In the case of states within a single symmetry manifold the relative intensities will be independent of recoil momentum up to some maximum, usually at least a few atomic units

  9. Measure the constituents of geological samples by XRF intensity influence coefficient method

    International Nuclear Information System (INIS)

    Dai Zhenlin; Ge Liangquan; Cheng Feng; Zhang Qingxian

    2008-01-01

    The elements of some ore samples (including primary ores in the mine) have been measured by using the Si-PIN detector and the portable high energy resolution XRF analyzer with an embedded computer constituting the intensity correction model of influence coefficient method. By comparing to the result by chemical analysis, the conclusion could be made as follows: the maximal relative error of the content of the element Fe with the content between 20% to 55% is not more than 4.74%, the maximal relative error of the content of the element Cu with the content between 182ppm to 2400ppm is not more than 24. 70% and not more than 7.46% with the content between 2400ppm to 3600ppm, the maximal relative error of the content of the element Zn with the content between 556ppm to 3200ppm is not more than 25. 93% and not more than 4.74% with the content between 3200ppm to 21600ppm, the maximal relative error of the content of the element Pb with the content between 5900ppm to 204200ppm is not more than 23.80% and not more than 13.79% with the content between 204200ppm to 511200ppm. In this way, this model could overcome the influence of matrix effect from base material components commendably and guide the work of mineral beneficiation in the mine effectively. (authors)

  10. Fast-turnaround alkyl nitrate measurements during the PROPHET 1998 summer intensive

    Science.gov (United States)

    Ostling, Kristi; Kelly, Brendan; Bird, Stephen; Bertman, Steven; Pippin, Margaret; Thornberry, Troy; Carroll, Mary Anne

    2001-10-01

    An automated gas chromatographic system for making fast-turnaround measurements of alkyl nitrates was developed and tested. Every 30 min, samples were automatically acquired on a 1/16-inch OD Tenax trap made from fused silica-lined stainless steel tubing and injected by thermal desorption into the gas chromatograph. The system exhibited good chromatographic resolution, minimal breakthrough, and on-trap stability for C3-C5 nitrates. The detection limit of the instrument was Biological Station in northern Michigan during the summer of 1998 from July 15 to August 22. Ambient results show a significant dynamic range with absolute levels affected by air mass history and pollution sources. The sum of measured C3-C5 alkyl nitrates obtained during this intensive ranged from 3.45 to 65.8 pptv, with a mean of 18.6 pptv and contributed 1% on average to total NOy, with a range of 0.5% to 3%. Differences in the contribution to NOy are found when the data are filtered according to air mass origin. A positive relationship between n-propyl nitrate and peroxypropionyl nitrate was observed over the course of the intensive.

  11. Increasing land-use intensity reverses the relative occupancy of two quadrupedal scavengers.

    Directory of Open Access Journals (Sweden)

    Joshua P Twining

    Full Text Available Human land use is continuously altering the natural environment, yet the greater ecological implications of this change for many groups that are key to healthy ecosystem functioning remains uncharacterised in the tropics. Terrestrial scavenging vertebrates are one such group, providing integral ecosystem services through the removal of carrion which is a crucial component of both nutrient cycling and disease dynamics. To explore how anthropogenic processes may affect forest scavengers, we investigated the changes in the relative occupancy of two important terrestrial scavengers along a gradient of land use intensity, ranging from protected forest to oil palm plantation in Borneo. We found the Malay civet (Viverra tangalunga had highest, albeit variable, occupancy in areas of low land use intensity and the Southeast Asian water monitor (Varanus salvator macromaculatus had highest occupancy in areas of high land use intensity. Land use had no effect on the combined occupancy of the two species. In high land use intensity sites, individual water monitors were larger and had better body condition, but at population level had a highly biased sex ratio with more males than females and increased signs of intraspecific conflict. We did not assess scavenging rate or efficiency as a process, but the high occupancy rates and apparent health of the scavengers in high land use intensity landscapes suggests this ecological process is robust to land use change.

  12. Intensity, but not duration, of physical activities is related to cognitive function

    NARCIS (Netherlands)

    Angevaren, Maaike; Vanhees, Luc; Wendel-Vos, Wanda; Verhaar, Harald J. J.; Aufdernkarnpe, Geert; Aleman, Andrie; Verschuren, W. M. Monique

    2007-01-01

    Background Physical activity is thought to facilitate cognitive performance and to slow down the rate of age-related cognitive decline. This study aimed to investigate the association between the time spent on physical activity as well as the average intensity of these activities and cognitive

  13. Intensity, but not duration of physical activities is related to cognitive function.

    NARCIS (Netherlands)

    A. Aleman; Geert Aufdemkampe; H.J. Verhaar; W. Wendel-Vos; Drs. Maaike Angevaren; Prof. Dr. Luc L.E.M.J. Vanhees; W.M. Verschuren

    2007-01-01

    Background: Physical activity is thought to facilitate cognitive performance and to slow down the rate of age-related cognitive decline. This study aimed to investigate the association between the time spent on physical activity as well as the average intensity of these activities and cognitive

  14. The AD and ELENA orbit, trajectory and intensity measurement systems

    Science.gov (United States)

    Marco-Hernández, R.; Alves, D.; Angoletta, M. E.; Marqversen, O.; Molendijk, J.; Oponowicz, E.; Ruffieux, R.; Sánchez-Quesada, J.; SØby, L.

    2017-07-01

    This paper describes the new Antiproton Decelerator (AD) orbit measurement system and the Extra Low ENergy Antiproton ring (ELENA) orbit, trajectory and intensity measurement system. The AD machine at European Organization for Nuclear Research (CERN) is presently being used to decelerate antiprotons from 3.57 GeV/c to 100 MeV/c for matter vs anti-matter comparative studies. The ELENA machine, presently under commissioning, has been designed to provide an extra deceleration stage down to 13.7 MeV/c. The AD orbit system is based on 32 horizontal and 27 vertical electrostatic Beam Position Monitor (BPM) fitted with existing low noise front-end amplifiers while the ELENA system consists of 24 \\gls{BPM}s equipped with new low-noise head amplifiers. In both systems the front-end amplifiers generate a difference (delta) and a sum (sigma) signal which are sent to the digital acquisition system, placed tens of meters away from the AD or ELENA rings, where they are digitized and further processed. The beam position is calculated by dividing the difference signal by the sum signal either using directly the raw digitized data for measuring the turn-by-turn trajectory in the ELENA system or after down-mixing the signals to baseband for the orbit measurement in both machines. The digitized sigma signal will be used in the ELENA system to calculate the bunched beam intensity and the Schottky parameters with coasting beam after passing through different signal processing chain. The digital acquisition arrangement for both systems is based on the same hardware, also used in the ELENA Low Level Radio Frequency (LLRF) system, which follows the VME Switched Serial (VXS) enhancement of the Versa Module Eurocard 64x extension (VME64x) standard and includes VITA 57 standard Field Programmable Gate Array Mezzanine Card (FMC). The digital acquisition Field Programmable Gate Array (FPGA) and Digital Signal Processor (DSP) firmware shares many common functionalities with the LLRF system but

  15. Sound intensity

    DEFF Research Database (Denmark)

    Crocker, Malcolm J.; Jacobsen, Finn

    1998-01-01

    This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique.......This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique....

  16. Sound Intensity

    DEFF Research Database (Denmark)

    Crocker, M.J.; Jacobsen, Finn

    1997-01-01

    This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique.......This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique....

  17. Usefulness of creep work-time relation for determining stress intensity limit of high-temperature components

    International Nuclear Information System (INIS)

    Kim, Woo Gon; Ryu, Woo Seog; Lee, Kyung Yong

    2003-01-01

    In order to determine creep stress intensity limit of high-temperature components, the usefulness of the creep work and time equation, defined as W c t p = B (where W c = σ ε is the total creep work done during creep, and p and B are constants), was investigated using the experimental data. For this purpose, the creep tests for generating 1.0% strain for commercial type 316 stainless steel were conducted with different stresses; 160 MPa, 150 MPa, 145 MPa, 140 MPa and 135 MPa at 593 .deg. C. The plots of log W c - log t showed a good linear relation up to 10 5 hr, and the results of the creep work-time relation for p, B and stress intensity values showed good agreement to those of Isochronous Stress-Strain Curves (ISSC) presented in ASME BPV NH. The relation can be simply obtained with only several short-term 1% strain data without ISSC which can be obtained by long-term creep data. Particularly, this relation is useful in estimating stress intensity limit for new and emerging class of high-temperature creeping materials

  18. Measurements of magnetic fields generated in underdense plasmas by intense lasers

    International Nuclear Information System (INIS)

    Najmudin, Z.; Walton, B. R.; Mangles, S. P. D.; Dangor, A. E.; Krushelnick, K.; Fritzler, S.; Malka, V.; Faure, J.; Tatarakis, M.

    2006-01-01

    Measurements have been made of the magnetic field generated by the passage of high intensity short laser pulses through underdense plasmas. For a 30 fs, 1 J, 800 nm linearly-polarised laser pulse, an azimuthal magnetic field is observed at a radial extent of approximately 200 μm. The field is found to exceed 2.8 MG. For a 1 ps, 40 J, 1054 nm circularly-polarised laser pulse, a solenoidal field is observed that can exceed 7 MG. This solenoidal field is absent with linear polarised light, and hence can be considered as an Inverse Faraday effect. Both types of field are found to decay on the picosecond timescale. For both the azimuthal and solenoidal fields produced by such intense lasers, the production of energetic electrons by the interaction is thought to be vital for magnetic field generation

  19. Trends in Intense Typhoon Minimum Sea Level Pressure

    Directory of Open Access Journals (Sweden)

    Stephen L. Durden

    2012-01-01

    Full Text Available A number of recent publications have examined trends in the maximum wind speed of tropical cyclones in various basins. In this communication, the author focuses on typhoons in the western North Pacific. Rather than maximum wind speed, the intensity of the storms is measured by their lifetime minimum sea level pressure (MSLP. Quantile regression is used to test for trends in storms of extreme intensity. The results indicate that there is a trend of decreasing intensity in the most intense storms as measured by MSLP over the period 1951–2010. However, when the data are broken into intervals 1951–1987 and 1987–2010, neither interval has a significant trend, but the intensity quantiles for the two periods differ. Reasons for this are discussed, including the cessation of aircraft reconnaissance in 1987. The author also finds that the average typhoon intensity is greater in El Nino years, while the intensity of the strongest typhoons shows no significant relation to El Nino Southern Oscillation.

  20. A Bayesian framework for estimating moment magnitude and its uncertainty from macroseismic intensity measures

    Science.gov (United States)

    Kawabata, E.; Main, I. G.; Naylor, M.; Chandler, R. E.

    2016-12-01

    In moderate to low seismicity areas such as the UK, earthquakes represent a small but not negligible risk to sensitive structures such as nuclear power plants. As a part of the safety case in the planning and regulation of such structures, seismic activity must first be monitored and quantified to form a catalogue of past events. In a low or moderate seismicity zone, most of our knowledge of the most significant events comes from macroseismic intensity measures from the pre-instrumental period (before 1900). These historical records must then be combined and calibrated with modern analogue and digitally-recorded instrumental data on a common source magnitude scale, the most useful of which is the moment magnitude. The result is a unified catalogue that can be used for probabilistic seismic hazard analysis. An isoseismal map involves a set of contours that enclose the areas at which the event was felt at particular intensity values or higher, called felt areas. It has been common practice to draw these contours by hand with varying degrees of subjectivity. Here, we demonstrate a Bayesian method for constructing such maps objectively from macroseismic intensity measures and their observed locations. It involves using mathematical expressions to represent concentric ellipses and estimating their optimal parameters and uncertainties in a Bayesian framework. Inferred fault orientations in the UK are predominantly vertical, so the elliptical assumption is reasonable at least to first order or as a null hypothesis. Relevant physical constraints are used as priors where available. The resulting posterior distributions are used to calculate felt area at a given intensity, as well as a probability density function for the inferred epicentre. We then describe another Bayesian approach for deriving moment magnitude from felt areas based on their relationship and known constraints such as the frequency-magnitude distribution. The use of Bayesian inference allows us to quantify

  1. The design of a measuring system for soft X ray absolute intensity

    International Nuclear Information System (INIS)

    Cui Congwu; Cui Mingqi

    1997-01-01

    The design of a measuring system for soft X ray absolute intensity in detail is presented. The system consists of two parts: the ionization chamber, the silicon photodiode and its transferring system. The system can be used as the primary standard detector for the measurement of soft X ray absolute radiation flux in the energy range of 50 to 2000 eV after being calibrated. The whole system will be installed to the newly built beamline of 3W1B at Beijing Synchrotron Radiation Facility

  2. Can Intensity-Modulated Radiotherapy Preserve Oral Health-Related Quality of Life of Nasopharyngeal Carcinoma Patients?

    International Nuclear Information System (INIS)

    Pow, Edmond H.N.; Kwong, Dora L.W.; Sham, Jonathan S.T.; Lee, Victor H.F.; Ng, Sherry C.Y.

    2012-01-01

    Purpose: To investigate the changes in salivary function and oral health-related quality of life for patients with nasopharyngeal carcinoma treated by intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 57 patients with early-stage nasopharyngeal carcinoma received IMRT. The parotid and whole saliva flow was measured, and the Medical Outcomes Study 36-item short form, European Organization for Research and Treatment of Cancer Quality of Life questionnaire-C30, European Organization for Research and Treatment of Cancer Quality of Life questionnaire 35-item head-and-neck module, and Oral Health Impact Profile questionnaires were completed at baseline and 2, 6, 12, 18, and 24 months after IMRT. Results: Parotid saliva flow recovered fully after 1 year and maintained. Whole saliva flow recovered partially to 40% of baseline. A general trend of deterioration in most quality of life scales was observed after IMRT, followed by gradual recovery. Persistent oral-related symptoms were found 2 years after treatment. Conclusion: IMRT for early-stage nasopharyngeal carcinoma could only partially preserve the whole salivary function and oral health-related quality of life.

  3. Can Intensity-Modulated Radiotherapy Preserve Oral Health-Related Quality of Life of Nasopharyngeal Carcinoma Patients?

    Energy Technology Data Exchange (ETDEWEB)

    Pow, Edmond H.N., E-mail: ehnpow@hku.hk [Oral Rehabilitation, University of Hong Kong Faculty of Dentistry, Hong Kong Special Administrative Region (China); Kwong, Dora L.W.; Sham, Jonathan S.T.; Lee, Victor H.F.; Ng, Sherry C.Y. [Department of Clinical Oncology, University of Hong Kong Li Ka Shing Faculty of Medicine, Hong Kong Special Administrative Region (Hong Kong)

    2012-06-01

    Purpose: To investigate the changes in salivary function and oral health-related quality of life for patients with nasopharyngeal carcinoma treated by intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 57 patients with early-stage nasopharyngeal carcinoma received IMRT. The parotid and whole saliva flow was measured, and the Medical Outcomes Study 36-item short form, European Organization for Research and Treatment of Cancer Quality of Life questionnaire-C30, European Organization for Research and Treatment of Cancer Quality of Life questionnaire 35-item head-and-neck module, and Oral Health Impact Profile questionnaires were completed at baseline and 2, 6, 12, 18, and 24 months after IMRT. Results: Parotid saliva flow recovered fully after 1 year and maintained. Whole saliva flow recovered partially to 40% of baseline. A general trend of deterioration in most quality of life scales was observed after IMRT, followed by gradual recovery. Persistent oral-related symptoms were found 2 years after treatment. Conclusion: IMRT for early-stage nasopharyngeal carcinoma could only partially preserve the whole salivary function and oral health-related quality of life.

  4. Construction and psychometric testing of the EMPATHIC questionnaire measuring parent satisfaction in the pediatric intensive care unit

    NARCIS (Netherlands)

    Latour, Jos M.; van Goudoever, Johannes B.; Duivenvoorden, Hugo J.; Albers, Marcel J. I. J.; van Dam, Nicolette A. M.; Dullaart, Eugenie; van Heerde, Marc; de Neef, Marjorie; Verlaat, Carin W. M.; van Vught, Elise M.; Hazelzet, Jan A.

    To construct and test the reliability and validity of the EMpowerment of PArents in THe Intensive Care (EMPATHIC) questionnaire measuring parent satisfaction in the pediatric intensive care unit (PICU). Structured development and psychometric testing of a parent satisfaction-with-care instrument

  5. Construction and psychometric testing of the EMPATHIC questionnaire measuring parent satisfaction in the pediatric intensive care unit

    NARCIS (Netherlands)

    Latour, J.M.; van Goudoever, J.B.; Duivenvoorden, H.J.; Albers, M.J.I.J.; van Dam, N.A.M.; Dullaart, E.; van Heerde, M.; de Neef, M.; Verlaat, C.W.M.; van Vught, E.M.; Hazelzet, J.A.

    2011-01-01

    To construct and test the reliability and validity of the EMpowerment of PArents in THe Intensive Care (EMPATHIC) questionnaire measuring parent satisfaction in the pediatric intensive care unit (PICU). Structured development and psychometric testing of a parent satisfaction-with-care instrument

  6. Intensity and bunch length measurement for lepton beam in the injection lines of the SPS and LEP

    CERN Document Server

    Boccard, C; Papis, J P; Vos, L

    1995-01-01

    We describe a system which is used operationally to measure the absolute intensity of single lepton bunches in a beam transfer line. It is based on the detailed knowledge of every single item of a complex measuring chain that comprises a beam coupler on one end and an acquisition system on the other end. This knowledge can be acquired by a well tested theoretical model and careful measurement of the transfer function of each processing module. A precision better than 3 % can be obtained and no external calibration is required. A value for the bunch length can be deduced from a spectral intensity measurement at two well chosen frequencies.

  7. Infiltration and Runoff Measurements on Steep Burned Hillslopes Using a Rainfall Simulator with Variable Rain Intensities

    Science.gov (United States)

    Kinner, David A.; Moody, John A.

    2008-01-01

    Multiple rainfall intensities were used in rainfall-simulation experiments designed to investigate the infiltration and runoff from 1-square-meter plots on burned hillslopes covered by an ash layer of varying thickness. The 1-square-meter plots were on north- and south-facing hillslopes in an area burned by the Overland fire northwest of Boulder near Jamestown on the Front Range of Colorado. A single-nozzle, wide-angle, multi-intensity rain simulator was developed to investigate the infiltration and runoff on steep (30- to 40-percent gradient) burned hillslopes covered with ash. The simulated rainfall was evaluated for spatial variability, drop size, and kinetic energy. Fourteen rainfall simulations, at three intensities (about 20 millimeters per hour [mm/h], 35 mm/h, and 50 mm/h), were conducted on four plots. Measurements during and after the simulations included runoff, rainfall, suspended-sediment concentrations, surface ash layer thickness, soil moisture, soil grain size, soil lost on ignition, and plot topography. Runoff discharge reached a steady state within 7 to 26 minutes. Steady infiltration rates with the 50-mm/h application rainfall intensity approached 20?35 mm/h. If these rates are projected to rainfall application intensities used in many studies of burned area runoff production (about 80 mm/h), the steady discharge rates are on the lower end of measurements from other studies. Experiments using multiple rainfall intensities (three) suggest that runoff begins at rainfall intensities around 20 mm/h at the 1-square-meter scale, an observation consistent with a 10-mm/h rainfall intensity threshold needed for runoff initiation that has been reported in the literature.

  8. Role of soil biology and soil functions in relation to land use intensity.

    Science.gov (United States)

    Bondi, Giulia; Wall, David; Bacher, Matthias; Emmet-Booth, Jeremy; Graça, Jessica; Marongiu, Irene; Creamer, Rachel

    2017-04-01

    The delivery of the ecosystem's functions is predominantly controlled by soil biology. The biology found in a gram of soil contains more than ten thousand individual species of bacteria and fungi (Torsvik et al., 1990). Understanding the role and the requirements of these organisms is essential for the protection and the sustainable use of soils. Soil biology represents the engine of all the processes occurring in the soil and it supports the ecosystem services such as: 1) nutrient mineralisation 2) plant production 3) water purification and regulation and 4) carbon cycling and storage. During the last years land management type and intensity have been identified as major drivers for microbial performance in soil. For this reason land management needs to be appropriately studied to understand the role of soil biology within this complex interplay of functions. We aimed to study whether and how land management drives soil biological processes and related functions. To reach this objective we built a land use intensity index (LUI) able to quantify the impact of the common farming practices carried out in Irish grassland soils. The LUI is derived from a detailed farmer questionnaire on grassland management practices at 38 farms distributed in the five major agro-climatic regions of Ireland defined by Holden and Brereton (2004). Soils were classified based on their drainage status according to the Irish Soil Information System by Creamer et al. (2014). This detailed questionnaire is then summarised into 3 management intensity components: (i) intensity of Fertilisation (Fi), (ii) frequency of Mowing (Mi) and (iii) intensity of Livestock Grazing (Gi). Sites were sampled to assess the impact of land management intensity on microbial community structure and enzyme behaviour in relation to nitrogen, phosphorus and carbon cycling. Preliminary results for enzymes linked to C and N cycles showed higher activity in relation to low grazing pressure (low Gi). Enzymes linked to P

  9. Simultaneous measurement of refractive index and temperature based on intensity demodulation using matching grating method.

    Science.gov (United States)

    Qi, Liang; Zhao, Chun-Liu; Kang, Juan; Jin, Yongxing; Wang, Jianfeng; Ye, Manping; Jin, Shangzhong

    2013-07-01

    A solution refractive index (SRI) and temperature simultaneous measurement sensor with intensity-demodulation system based on matching grating method were demonstrated. Long period grating written in a photonic crystal fiber (LPG-PCF), provides temperature stable and wavelength dependent optical intensity transmission. The reflective peaks of two fiber Bragg gratings (FBGs), one of which is etched then sensitive to both SRI and temperature, another (FBG2) is only sensitive to temperature, were located in the same linear range of the LPG-PCF's transmission spectrum. An identical FBG with FBG2 was chosen as a matching FBG. When environments (SRI and temperature) change, the wavelength shifts of the FBGs are translated effectively to the reflection intensity changes. By monitoring output lights of unmatching and matching paths, the SRI and temperature were deduced by a signal processing unit. Experimental results show that the simultaneous refractive index and temperature measurement system work well. The proposed sensor system is compact and suitable for in situ applications at lower cost.

  10. Disparity in formulations used for fluorescent X-ray intensity measurements

    International Nuclear Information System (INIS)

    Mittal, Raj; Gupta, Sheenu

    2011-01-01

    The paper presents a problem in computations of X-ray fluorescence cross-sections, shell/sub-shell fluorescence yields, Coster-Kronig yields, vacancy alignment, etc. from X-ray fluorescence (XRF) studies. While using barn/atom as a unit for cross-sections if the atomic masses are not considered it causes a discrepancy in the measured cross-section, yield and alignment values. Most of the earlier publications are being quoted where such an oversight has occurred and discrepancy is evident. - Highlights: → Manuscript gives basic formulation for measurements of fluorescent X-ray intensities. → Most publications ignored the fact that use of barn/atom units for cross-sections requires atomic masses. → Published experimental results higher by a factor ≥2 or less by factor 1/M K . → Inspection of published data on XRF parameters needed.

  11. Energetic Neutral Atom (ENA) intensity gradients in the heliotail during year 2003, using Cassini/INCA measurements

    International Nuclear Information System (INIS)

    Dialynas, K; Krimigis, S M; Mitchell, D G; Roelof, E C

    2015-01-01

    In the present study we use all-sky energy-resolved (5-55 keV) energetic neutral atom (ENA) maps obtained by the Ion and Neutral CAmera (INCA) on board Cassini during the time period DOY 265/2003 to 268/2003, to investigate the properties of the peak-to-basin ENA emissions in the direction of the heliotail. Our conclusions can be summarized as follows: (1) a relatively smooth boundary (called t ransition region ) between the very low (basin) and high (tail) ENA emissions from the heliosheath, with a spatial width of ∼30° deg in ecl. longitude, that no theory had predicted to date, is identified in the energy range of 5-55 keV; (2) the ENA intensity gradient in this transition region is almost invariant as a function of both ecl. Latitude and energy, with an average value of ∼2.4% per degree; (3) the deduced partial plasma pressure distributions in the 5-55 keV energy range are consistent with the ENA intensity distributions in the same energy range, while the ENA intensity gradient translates to a corresponding partial pressure gradient that occurs in the transition region; and (4) this partial pressure gradient is possibly not consistent with a tail magnetic field configuration that is similar to the measured magnetic fields by the Voyagers in the nose hemisphere

  12. Measuring gas concentration and wind intensity in a turbulent wind tunnel with a mobile robot

    OpenAIRE

    Martínez Lacasa, Daniel; Moreno Blanc, Javier; Tresánchez, Marcel; Clotet Bellmunt, Eduard; Jiménez-Soto, Juan M.; Magrans, Rudys; Pardo Martínez, Antonio; Marco Colás, Santiago; Palacín Roca, Jordi

    2016-01-01

    This paper presents themeasurement of gas concentration and wind intensity performed with amobile robot in a customturbulent wind tunnel designed for experimentation with customizable wind and gas leak sources.This paper presents the representation in different information layers of the measurements obtained in the turbulent wind tunnel under different controlled environmental conditions in order to describe the plume of the gas and wind intensities inside the experimentation chamber...

  13. Quality of care in the intensive care unit from the perspective of patient's relatives: development and psychometric evaluation of the consumer quality index 'R-ICU'.

    Science.gov (United States)

    Rensen, Ans; van Mol, Margo M; Menheere, Ilse; Nijkamp, Marjan D; Verhoogt, Ellen; Maris, Bea; Manders, Willeke; Vloet, Lilian; Verharen, Lisbeth

    2017-01-24

    The quality standards of the Dutch Society of Intensive Care require monitoring of the satisfaction of patient's relatives with respect to care. Currently, no suitable instrument is available in the Netherlands to measure this. This study describes the development and psychometric evaluation of the questionnaire-based Consumer Quality Index 'Relatives in Intensive Care Unit' (CQI 'R-ICU'). The CQI 'R-ICU' measures the perceived quality of care from the perspective of patients' relatives, and identifies aspects of care that need improvement. The CQI 'R-ICU' was developed using a mixed method design. Items were based on quality of care aspects from earlier studies and from focus group interviews with patients' relatives. The time period for the data collection of the psychometric evaluation was from October 2011 until July 2012. Relatives of adult intensive care patients in one university hospital and five general hospitals in the Netherlands were approached to participate. Psychometric evaluation included item analysis, inter-item analysis, and factor analysis. Twelve aspects were noted as being indicators of quality of care, and were subsequently selected for the questionnaire's vocabulary. The response rate of patients' relatives was 81% (n = 455). Quality of care was represented by two clusters, each showing a high reliability: 'Communication' (α = .80) and 'Participation' (α = .84). Relatives ranked the following aspects for quality of care as most important: no conflicting information, information from doctors and nurses is comprehensive, and health professionals take patients' relatives seriously. The least important care aspects were: need for contact with peers, nuisance, and contact with a spiritual counsellor. Aspects that needed the most urgent improvement (highest quality improvement scores) were: information about how relatives can contribute to the care of the patient, information about the use of meal-facilities in the hospital, and

  14. Direct measurement of the energy spectrum of an intense proton beam

    International Nuclear Information System (INIS)

    Leeper, R.J.; Lee, J.R.; Kissel, L.; Johnson, D.J.; Stygar, W.A.; Hebron, D.E.; Roose, L.D.

    1983-01-01

    A time-resolved magnetic spectrometer has been used to measure the energy spectrum of an intense (0.5 TW/cm 2 ) proton beam. A thin (2400 A) gold foil placed at the focus of an ion diode Rutherford scattered protons by 90 0 into the spectrometer, reducing the beam intensity to a level suitable for magnetic analysis. The scattered beam was collimated by two 1 mm diameter apertures separated by 12.3 cm. The collimated protons were deflected in a 12.7 cm diameter, 6.65 Kg samarium-cobalt permanent magnet. The deflected protons were recorded simultaneously on CR-39 and eight 1 mm 2 by 35 μm thick PIN diodes. A Monte Carlo computer code was used to calculate the sensitivity and resolution of the spectrometer. Data taken on Proto-I show a 150 keV to 250 keV wide proton energy spectrum at each instant in time

  15. Tritium solid targets for intense D-T neutron production and its related problems

    International Nuclear Information System (INIS)

    Sumita, Kenji

    1988-01-01

    This review paper is divided into three parts. Firstly, to attain an intense neutron production rate, the construction of a design with a higher tritium-containing surface and an effective cooling system like a rotating target device are discussed. The maximum attainable intensity based on tritium solid targets shall be estimated regarding planning for future D-T sources. Secondly, on the way to carry out some experiments, an absolute intensity calibration and an angular dependent neutron energy spectrum of the neutron source are essential parameters to analyse the results of the experiments. Sometimes the space dependent neutron spectrum is required as well as the space dependent neutron flux near the targets and irradiation samples. The measurement methods and their examples are reviewed for tritium solid targets. The third part is devoted to discuss the protection to tritium contamination problems due to unavoidable release of tritium gas from targets. Performance and effectiveness of tritium collection systems for intense D-T neutron sources shall be discussed in some examples. Tritium contamination incidents due to the faulted film powder of target surface are also reported in some real incident cases. (author). Abstract only

  16. Line intensities for diagnosing laser-produced plasmas

    International Nuclear Information System (INIS)

    Kauffman, R.L.; Matthews, D.L.; Lee, R.W.; Whitten, B.L.; Kilkenny, J.D.

    1983-01-01

    We have measured relative line intensities of the K x-ray spectra of Si, Cl, and Ca from laser-produced plasmas to assess their usefulness as a plasma diagnostic. The different elements are added at low concentrations to CH disks which are irradiated at 5 x 10 14 W/cm 2 with a 0.53 μm laser pulse of 20 Joules at 1 nsec. The concentration of each element is kept low in order not to change the Z of the plasma, and therefore the plasma dynamics. The various spectra are measured with a time-resolved spectrograph to obtain line intensities as a function of time over the length of the laser pulse. These relative intensities of various He-like and H-like lines are compared with calculations from a steady-state level population code. The results give good consistency among the various line ratios. Agreement is not as good for analysis of the Li-like satellite lines. Modelling of the Li-like lines need further investigation. 10 references, 9 figures

  17. Urinary catheter related nosocomial infections in paediatric intensive care unit.

    Directory of Open Access Journals (Sweden)

    Tullu M

    1998-04-01

    Full Text Available The present prospective study was carried out in the Paediatric Intensive Care Unit (PICU of a tertiary care teaching hospital in Mumbai. The objective was to determine the incidence, risk factors, mortality and organisms responsible for urinary catheter related infections (UCRI. Colonization and/or bacteriuria was labelled as urinary catheter related infection (UCRI. Forty-four patients with 51 urinary catheters were studied. Incidence of UCRI was 47.06%. Age, female sex and immunocompromised status did not increase the risk of UCRI. Duration of catheter in-situ and duration of stay in the PICU were associated with higher risk of UCRI. The mortality was not increased by UCRI. Commonest organism isolated in UCRI was E. coli, which had maximum susceptibility to nitrofurantoin and amikacin.

  18. Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients

    Directory of Open Access Journals (Sweden)

    Asadian S

    2016-09-01

    Full Text Available Simin Asadian,1 Alireza Khatony,1 Gholamreza Moradi,2 Alireza Abdi,1 Mansour Rezaei,3 1Nursing and Midwifery School, Kermanshah University of Medical Sciences, 2Department of Anesthesiology, 3Biostatistics & Epidemiology Department, Kermanshah University of Medical Sciences, Kermanshah, Iran Introduction: An accurate determination of body temperature in critically ill patients is a fundamental requirement for initiating the proper process of diagnosis, and also therapeutic actions; therefore, the aim of the study was to assess the accuracy and precision of four noninvasive peripheral methods of temperature measurement compared to the central nasopharyngeal measurement. Methods: In this observational prospective study, 237 patients were recruited from the intensive care unit of Imam Ali Hospital of Kermanshah. The patients’ body temperatures were measured by four peripheral methods; oral, axillary, tympanic, and forehead along with a standard central nasopharyngeal measurement. After data collection, the results were analyzed by paired t-test, kappa coefficient, receiver operating characteristic curve, and using Statistical Package for the Social Sciences, version 19, software. Results: There was a significant meaningful correlation between all the peripheral methods when compared with the central measurement (P<0.001. Kappa coefficients showed good agreement between the temperatures of right and left tympanic membranes and the standard central nasopharyngeal measurement (88%. Paired t-test demonstrated an acceptable precision with forehead (P=0.132, left (P=0.18 and right (P=0.318 tympanic membranes, oral (P=1.00, and axillary (P=1.00 methods. Sensitivity and specificity of both the left and right tympanic membranes were more than for other methods. Conclusion: The tympanic and forehead methods had the highest and lowest accuracy for measuring body temperature, respectively. It is recommended to use the tympanic method (right and left for

  19. Thermal expansion measurements by x-ray scattering and breakdown of Ehrenfest's relation in alloy liquids

    International Nuclear Information System (INIS)

    Gangopadhyay, A. K.; Blodgett, M. E.; Johnson, M. L.; Vogt, A. J.; Mauro, N. A.; Kelton, K. F.

    2014-01-01

    Measurements of sharp diffraction peaks as a function of temperature are routinely used to obtain precise linear expansion coefficients of crystalline solids. In this case, the relation between temperature dependent changes in peak position in momentum transfer (q 1 ) and volume expansion is straightforward (Ehrenfest's relation: q 1  = K(2π/d), where K is a constant and d is the interatomic spacing) and the data obtained are usually in close agreement with more direct measurements. With high intensity synchrotron x-ray and spallation neutron sources, it is also possible to accurately measure the positions of the much broader peaks for liquids and glasses. This has led to a debate on whether linear expansion coefficients derived from these data are an accurate representation of the volume expansion coefficients. We present here volume thermal expansion and x-ray diffraction data for a large number of glass-forming alloy liquids acquired in a containerless environment using the beamline electrostatic levitation technique. The data show a large difference in the values obtained from the two different techniques. Moreover, the position of the first peak (q 1 ) in the scattered intensity in the structure factor (S(q)) and the atomic volume v for all liquids follow a simple relationship, v∝(q 1 ) −ε . The exponent, ε = 2.28 (±0.11), is much different from the expected value of 3 from Ehrenfest's relation and shows no temperature dependence over the temperature range of the data collected

  20. Electron density profile measurements from hydrogen line intensity ratio method in Versatile Experimental Spherical Torus

    Energy Technology Data Exchange (ETDEWEB)

    Kim, YooSung; Shi, Yue-Jiang, E-mail: yjshi@snu.ac.kr; Yang, Jeong-hun; Kim, SeongCheol; Kim, Young-Gi; Dang, Jeong-Jeung; Yang, Seongmoo; Jo, Jungmin; Chung, Kyoung-Jae [Department of Nuclear Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Oh, Soo-Ghee [Division of Energy Systems Research, Ajou University, Suwon 442-749 (Korea, Republic of); Hwang, Y. S. [Department of Nuclear Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Center for Advanced Research in Fusion Reactor Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of)

    2016-11-15

    Electron density profiles of versatile experiment spherical torus plasmas are measured by using a hydrogen line intensity ratio method. A fast-frame visible camera with appropriate bandpass filters is used to detect images of Balmer line intensities. The unique optical system makes it possible to take images of H{sub α} and H{sub β} radiation simultaneously, with only one camera. The frame rate is 1000 fps and the spatial resolution of the system is about 0.5 cm. One-dimensional local emissivity profiles have been obtained from the toroidal line of sight with viewing dumps. An initial result for the electron density profile is presented and is in reasonable agreement with values measured by a triple Langmuir probe.

  1. Faraday Cup - it is used to measure beam intensities at low energy beams.

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    A Faraday Cup is used to measure beam intensities at low energy beams. An electrically isolated metallic electrode intercepts the beam and captures all its charges. These charges are integrated using an current sensitive amplifier. When the beam impinges onto the electrode surface low energy electrons are liberated. In order to prevent these electrons from escaping the cup and thus falsifying the measurement, a repeller electrode with negative potential pushes the electrons back onto the electrode.

  2. The design of the run Clever randomized trial: running volume, -intensity and running-related injuries.

    Science.gov (United States)

    Ramskov, Daniel; Nielsen, Rasmus Oestergaard; Sørensen, Henrik; Parner, Erik; Lind, Martin; Rasmussen, Sten

    2016-04-23

    Injury incidence and prevalence in running populations have been investigated and documented in several studies. However, knowledge about injury etiology and prevention is needed. Training errors in running are modifiable risk factors and people engaged in recreational running need evidence-based running schedules to minimize the risk of injury. The existing literature on running volume and running intensity and the development of injuries show conflicting results. This may be related to previously applied study designs, methods used to quantify the performed running and the statistical analysis of the collected data. The aim of the Run Clever trial is to investigate if a focus on running intensity compared with a focus on running volume in a running schedule influences the overall injury risk differently. The Run Clever trial is a randomized trial with a 24-week follow-up. Healthy recreational runners between 18 and 65 years and with an average of 1-3 running sessions per week the past 6 months are included. Participants are randomized into two intervention groups: Running schedule-I and Schedule-V. Schedule-I emphasizes a progression in running intensity by increasing the weekly volume of running at a hard pace, while Schedule-V emphasizes a progression in running volume, by increasing the weekly overall volume. Data on the running performed is collected by GPS. Participants who sustain running-related injuries are diagnosed by a diagnostic team of physiotherapists using standardized diagnostic criteria. The members of the diagnostic team are blinded. The study design, procedures and informed consent were approved by the Ethics Committee Northern Denmark Region (N-20140069). The Run Clever trial will provide insight into possible differences in injury risk between running schedules emphasizing either running intensity or running volume. The risk of sustaining volume- and intensity-related injuries will be compared in the two intervention groups using a competing

  3. Distribution measurement of radiation intensity with optical fiber at narrow space

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Chizuo [Nagoya Univ. (Japan). School of Engineering

    1998-07-01

    Recently, in the field or radiation measurement, optical fiber and scintillation fiber are also begun to use. In order to investigate a new application method of the optical fiber to radiation measurement, a lithium compound for neutron converter and a ZnS(Ag) scintillator are kneaded with epoxy type adhesives, and much few weight of them is coated at an end of optical fiber with 1 to 2 mm in diameter, which is further overcoated with black paint or an aluminum cap for its shielding light to produce a thermal neutron detector. The thermal neutron detector is found to be measurable to neutron flux distribution very rapidly and in high position resolution by moving with computer automatically. This method can be measured selctively aimed radiation such as thermal neutron, rapid neutron, {gamma}-ray, and so forth by means of changing the neutron converter. And, the developed fiber method could be widely used for measurement of neutron and {gamma}-ray intensity distribution at fine interval in the nuclear radiation facilities such as neighbors of accelerator facilities, medical radiation facilities. (G.K.)

  4. Plasmon band gap generated by intense ion acoustic waves

    International Nuclear Information System (INIS)

    Son, S.; Ku, S.

    2010-01-01

    In the presence of an intense ion acoustic wave, the energy-momentum dispersion relation of plasmons is strongly modified to exhibit a band gap structure. The intensity of an ion acoustic wave might be measured from the band gap width. The plasmon band gap can be used to block the nonlinear cascading channel of the Langmuir wave decay.

  5. Dependence of the muon intensity on the atmospheric temperature measured by the GRAPES-3 experiment

    Science.gov (United States)

    Arunbabu, K. P.; Ahmad, S.; Chandra, A.; Dugad, S. R.; Gupta, S. K.; Hariharan, B.; Hayashi, Y.; Jagadeesan, P.; Jain, A.; Jhansi, V. B.; Kawakami, S.; Kojima, H.; Mohanty, P. K.; Morris, S. D.; Nayak, P. K.; Oshima, A.; Rao, B. S.; Reddy, L. V.; Shibata, S.; Tanaka, K.; Zuberi, M.

    2017-09-01

    The large area (560 m2) GRAPES-3 tracking muon telescope has been operating uninterruptedly at Ooty, India since 2001. Every day, it records 4 × 109 muons of ≥1 GeV with an angular resolution of ∼4°. The variation of atmospheric temperature affects the rate of decay of muons produced by the galactic cosmic rays (GCRs), which in turn modulates the muon intensity. By analyzing the GRAPES-3 data of six years (2005-2010), a small (amplitude ∼0.2%) seasonal variation (1 year (Yr) period) in the intensity of muons could be measured. The effective temperature 'Teff' of the upper atmosphere also displays a periodic variation with an amplitude of ∼1 K which was responsible for the observed seasonal variation in the muon intensity. At GeV energies, the muons detected by the GRAPES-3 are expected to be anti-correlated with Teff. The anti-correlation between the seasonal variation of Teff, and the muon intensity was used to measure the temperature coefficient αT by fast Fourier transform (FFT) technique. The magnitude of αT was found to scale with the assumed attenuation length 'λ' of the hadrons in the range λ = 80-180 g cm-2. However, the magnitude of the correction in the muon intensity was found to be almost independent of the value of λ used. For λ = 120 g cm-2 the value of temperature coefficient αT was found to be (- 0.17 ± 0.02)% K-1.

  6. Effects of combined high intensity arm and leg training on performance and cardio-respiratory measures.

    Science.gov (United States)

    Zinner, Christoph; Sperlich, Billy; Born, Dennis-Peter; Michels, Guido

    2017-01-01

    The purpose of this study was to investigate the effects of combined arm and leg high-intensity low-volume interval training (HIITarm+leg) on maximal oxygen uptake, myocardial measures (i.e. stroke volume, cardiac output, ejection fraction), Tissue Oxygenation Index (TOI) of the vastus lateralis and triceps brachii, as well as power output in comparison to leg HIIT (HIITleg) only. The 20 healthy, male and female volunteers completed six sessions of either HIITleg on a cycle ergometer or HIITarm+leg on an arm and leg cycle ergometer. During pre- and post-testing, the volunteers completed a submaximal and incremental test to exhaustion on a cycle ergometer. Magnitude based interference revealed likely to very likely beneficial effects for HIITarm+leg compared to HIITleg in maximal oxygen uptake, cardiac measures as well peak power output. The TOI following HIITarm+leg demonstrated likely to very likely increased oxygenation in the triceps brachii or the vastus lateralis when compared to HIITleg. The results suggest that six sessions of HIITarm+leg may likely to very likely improve maximal oxygen uptake, some inotropy-related cardiac measures with improved tissue oxygenation of the triceps brachii and vastus lateralis muscles resulting in greater leg peak power output.

  7. Mean frequency and relative fluorescence intensity measurement of γ-H2AX foci dose response in PBL exposed to γ-irradiation: An inter- and intra-laboratory comparison and its relevance for radiation triage.

    Science.gov (United States)

    Venkateswarlu, Raavi; Tamizh, Selvan G; Bhavani, Manivannan; Kumar, Arun; Alok, Amit; Karthik, Kanagaraj; Kalra, Namita; Vijayalakshmi, J; Paul, Solomon F D; Chaudhury, N K; Venkatachalam, Perumal

    2015-12-01

    Measurement of γ-H2AX protein changes in the peripheral blood lymphocytes (PBL) of individuals exposed to ionizing radiation is a simple, sensitive, and rapid assay for radiation triage and early marker of dose estimation. The qualitative and quantitative measurements of the protein changes were examined using flow cytometry and microscopy. Whole blood and isolated lymphocytes were exposed in vitro between 0.1 and 5 Gy doses of (60) Co γ-radiation at a dose rate of 1 Gy/min. Radiation induced γ-H2AX foci frequency (n = 3) and relative fluorescence intensity (n = 7) in PBL was measured at 0.5 and 2 hrs postexposure. The observed dose response for γ-H2AX foci frequency at both time points, for whole blood and isolated lymphocytes did not show any significant (P > 0.05) differences. However, when compared with γ-H2AX foci frequency scored manually (microscopy), the semiautomated analysis (captured images) showed a better correlation (r(2) = 0.918) than that obtained with automated (Metafer) scoring (r(2) = 0.690). It is noteworthy to mention that, the γ-H2AX foci frequency quantified using microscopy showed a dose dependent increase up to 2 Gy and the relative fluorescence intensity (RFI) measured with flow cytometry revealed an increase up to 5 Gy in the PBL exposed in vitro. Moreover, a better correlation was observed between the γ-H2AX foci frequency obtained by manual scoring and RFI (r(2) = 0.910). Kinetic studies showed that the γ-H2AX foci remain more or less unchanged up to 4 hrs and reduces gradually over 48 hrs of postexposure at 37°C. Further, inter and intra-laboratory comparisons showed consistency in the scoring of γ-H2AX foci frequency by manual and semiautomated scoring. The overall results suggest that measurement of γ-H2AX (microscopy and flow cytometry) should be employed within 4 to 6 hrs for a reliable dosimetry either by sharing the work load between the laboratories or investing more manpower; however, triage can be possible even up

  8. A Cross-cultural Examination of SNS Usage Intensity and Managing Interpersonal Relationships Online: The Role of Culture and the Autonomous-Related Self-Construal

    Directory of Open Access Journals (Sweden)

    Lee eSoon Li

    2016-04-01

    Full Text Available Perception of the autonomy and relatedness of the self may be influenced by one’s experiences and social expectations within a particular cultural setting. The present research examined the role of culture and the Autonomous-Related self-construal in predicting for different aspects of Social Networking Sites (SNS usage in three Asian countries, especially focusing on those aspects serving interpersonal goals. Participants in this cross-cultural study included 305 university students from Malaysia (n = 105, South Korea (n = 113, and China (n = 87. The study explored specific social and interpersonal behaviors on SNS, such as browsing the contacts’ profiles, checking for updates, and improving contact with SNS contacts, as well as the intensity of SNS use, hypothesizing that those with high intensity of use in the Asian context may be doing so to achieve the social goal of maintaining contact and keeping updated with friends. Two scales measuring activities on other users’ profiles and contact with friends’ profiles were developed and validated. As predicted, some cross-cultural differences were found. Koreans were more likely to use SNS to increase contact but tended to spend less time browsing contacts’ profiles than the Malaysians and Chinese. The intensity of SNS use differed between the countries as well, where Malaysians reported higher intensity than Koreans and Chinese. Consistent with study predictions, Koreans were found with the highest Autonomous-Related self-construal scores. The Autonomous-Related self-construal predicted SNS intensity. The findings suggest that cultural contexts, along with the way the self is construed in different cultures, may encourage different types of SNS usage. The authors discuss study implications and suggest future research directions.

  9. A Cross-Cultural Examination of SNS Usage Intensity and Managing Interpersonal Relationships Online: The Role of Culture and the Autonomous-Related Self-Construal.

    Science.gov (United States)

    Lee, Soon Li; Kim, Jung-Ae; Golden, Karen Jennifer; Kim, Jae-Hwi; Park, Miriam Sang-Ah

    2016-01-01

    Perception of the autonomy and relatedness of the self may be influenced by one's experiences and social expectations within a particular cultural setting. The present research examined the role of culture and the Autonomous-Related self-construal in predicting for different aspects of Social Networking Sites (SNS) usage in three Asian countries, especially focusing on those aspects serving interpersonal goals. Participants in this cross-cultural study included 305 university students from Malaysia (n = 105), South Korea (n = 113), and China (n = 87). The study explored specific social and interpersonal behaviors on SNS, such as browsing the contacts' profiles, checking for updates, and improving contact with SNS contacts, as well as the intensity of SNS use, hypothesizing that those with high intensity of use in the Asian context may be doing so to achieve the social goal of maintaining contact and keeping updated with friends. Two scales measuring activities on other users' profiles and contact with friends' profiles were developed and validated. As predicted, some cross-cultural differences were found. Koreans were more likely to use SNS to increase contact but tended to spend less time browsing contacts' profiles than the Malaysians and Chinese. The intensity of SNS use differed between the countries as well, where Malaysians reported higher intensity than Koreans and Chinese. Consistent with study predictions, Koreans were found with the highest Autonomous-Related self-construal scores. The Autonomous-Related self-construal predicted SNS intensity. The findings suggest that cultural contexts, along with the way the self is construed in different cultures, may encourage different types of SNS usage. The authors discuss study implications and suggest future research directions.

  10. A Cross-Cultural Examination of SNS Usage Intensity and Managing Interpersonal Relationships Online: The Role of Culture and the Autonomous-Related Self-Construal

    Science.gov (United States)

    Lee, Soon Li; Kim, Jung-Ae; Golden, Karen Jennifer; Kim, Jae-Hwi; Park, Miriam Sang-Ah

    2016-01-01

    Perception of the autonomy and relatedness of the self may be influenced by one's experiences and social expectations within a particular cultural setting. The present research examined the role of culture and the Autonomous-Related self-construal in predicting for different aspects of Social Networking Sites (SNS) usage in three Asian countries, especially focusing on those aspects serving interpersonal goals. Participants in this cross-cultural study included 305 university students from Malaysia (n = 105), South Korea (n = 113), and China (n = 87). The study explored specific social and interpersonal behaviors on SNS, such as browsing the contacts' profiles, checking for updates, and improving contact with SNS contacts, as well as the intensity of SNS use, hypothesizing that those with high intensity of use in the Asian context may be doing so to achieve the social goal of maintaining contact and keeping updated with friends. Two scales measuring activities on other users' profiles and contact with friends' profiles were developed and validated. As predicted, some cross-cultural differences were found. Koreans were more likely to use SNS to increase contact but tended to spend less time browsing contacts' profiles than the Malaysians and Chinese. The intensity of SNS use differed between the countries as well, where Malaysians reported higher intensity than Koreans and Chinese. Consistent with study predictions, Koreans were found with the highest Autonomous-Related self-construal scores. The Autonomous-Related self-construal predicted SNS intensity. The findings suggest that cultural contexts, along with the way the self is construed in different cultures, may encourage different types of SNS usage. The authors discuss study implications and suggest future research directions. PMID:27148100

  11. Electric Field Measurement of the Living Human Body for Biomedical Applications: Phase Measurement of the Electric Field Intensity

    Directory of Open Access Journals (Sweden)

    Ichiro Hieda

    2013-01-01

    Full Text Available The authors are developing a technique for conducting measurements inside the human body by applying a weak electric field at a radio frequency (RF. Low RF power is fed to a small antenna, and a similar antenna located 15–50 cm away measures the electric field intensity. Although the resolution of the method is low, it is simple, safe, cost-effective, and able to be used for biomedical applications. One of the technical issues suggested by the authors' previous studies was that the signal pattern acquired from measurement of a human body was essentially different from that acquired from a phantom. To trace the causes of this difference, the accuracy of the phase measurements was improved. This paper describes the new experimental system that can measure the signal phase and amplitude and reports the results of experiments measuring a human body and a phantom. The results were analyzed and then discussed in terms of their contribution to the phase measurement.

  12. Relative emissions intensity of dairy production systems: employing different functional units in life-cycle assessment.

    Science.gov (United States)

    Ross, S A; Topp, C F E; Ennos, R A; Chagunda, M G G

    2017-08-01

    This study aimed to assess the merit and suitability of individual functional units (FU) in expressing greenhouse gas emissions intensity in different dairy production systems. An FU provides a clearly defined and measurable reference to which input and output data are normalised. This enables the results from life-cycle assessment (LCA) of different systems to be treated as functionally equivalent. Although the methodological framework of LCA has been standardised, selection of an appropriate FU remains ultimately at the discretion of the individual study. The aim of the present analysis was to examine the effect of different FU on the emissions intensities of different dairy production systems. Analysis was based on 7 years of data (2004 to 2010) from four Holstein-Friesian dairy systems at Scotland's Rural College's long-term genetic and management systems project, the Langhill herd. Implementation of LCA accounted for the environmental impacts of the whole-farm systems and their production of milk from 'cradle to farm gate'. Emissions intensity was determined as kilograms of carbon dioxide equivalents referenced to six FU: UK livestock units, energy-corrected milk yield, total combined milk solids yield, on-farm land used for production, total combined on- and off-farm land used for production, and the proposed new FU-energy-corrected milk yield per hectare of total land used. Energy-corrected milk was the FU most effective for reflecting differences between the systems. Functional unit that incorporated a land-related aspect did not find difference between systems which were managed under the same forage regime, despite their comprising different genetic lines. Employing on-farm land as the FU favoured grazing systems. The proposed dual FU combining both productivity and land use did not differentiate between emissions intensity of systems as effectively as the productivity-based units. However, this dual unit displayed potential to quantify in a simple way

  13. Sour Taste preferences of children relate to preference of novel and intense stimuli

    NARCIS (Netherlands)

    Liem, D.G.; Westerbeek, A.; Wolterink, S.; Kok, F.J.; Graaf, de C.

    2004-01-01

    Previous research has suggested that some children have a preference for sour tastes. The origin of this preference remains unclear. We investigated whether preference for sour tastes is related to a difference in rated sour intensity due to physiological properties of saliva, or to an overall

  14. Measurement and interpretation of threshold stress intensity factors for steels in high-pressure hydrogen gas.

    Energy Technology Data Exchange (ETDEWEB)

    Dadfarnia, Mohsen (University of Illinois at Urbana-Champaign, Urbana, IL); Nibur, Kevin A.; San Marchi, Christopher W.; Sofronis, Petros (University of Illinois at Urbana-Champaign, Urbana, IL); Somerday, Brian P.; Foulk, James W., III; Hayden, Gary A. (CP Industries, McKeesport, PA)

    2010-07-01

    Threshold stress intensity factors were measured in high-pressure hydrogen gas for a variety of low alloy ferritic steels using both constant crack opening displacement and rising crack opening displacement procedures. The sustained load cracking procedures are generally consistent with those in ASME Article KD-10 of Section VIII Division 3 of the Boiler and Pressure Vessel Code, which was recently published to guide design of high-pressure hydrogen vessels. Three definitions of threshold were established for the two test methods: K{sub THi}* is the maximum applied stress intensity factor for which no crack extension was observed under constant displacement; K{sub THa} is the stress intensity factor at the arrest position for a crack that extended under constant displacement; and K{sub JH} is the stress intensity factor at the onset of crack extension under rising displacement. The apparent crack initiation threshold under constant displacement, K{sub THi}*, and the crack arrest threshold, K{sub THa}, were both found to be non-conservative due to the hydrogen exposure and crack-tip deformation histories associated with typical procedures for sustained-load cracking tests under constant displacement. In contrast, K{sub JH}, which is measured under concurrent rising displacement and hydrogen gas exposure, provides a more conservative hydrogen-assisted fracture threshold that is relevant to structural components in which sub-critical crack extension is driven by internal hydrogen gas pressure.

  15. High-intensity resistance training in multiple sclerosis - An exploratory study of effects on immune markers in blood and cerebrospinal fluid, and on mood, fatigue, health-related quality of life, muscle strength, walking and cognition.

    Science.gov (United States)

    Kierkegaard, Marie; Lundberg, Ingrid E; Olsson, Tomas; Johansson, Sverker; Ygberg, Sofia; Opava, Christina; Holmqvist, Lotta Widén; Piehl, Fredrik

    2016-03-15

    High-intensity resistance training is unexplored in people with multiple sclerosis. To evaluate effects of high-intensity resistance training on immune markers and on measures of mood, fatigue, health-related quality of life, muscle strength, walking and cognition. Further, to describe participants' opinion and perceived changes of the training. Twenty patients with relapsing-remitting multiple sclerosis performed high-intensity resistance training at an intensity of 80% of one-repetition maximum, twice a week for 12 weeks. Blood and optional cerebrospinal fluid samples, and data on secondary outcome measures were collected before and after intervention. A study-specific questionnaire was used for capturing participants' opinion. Seventeen participants completed the study. Plasma cytokine levels of tumor necrosis factor were significantly decreased post-intervention (p=0.001). Exploratory cytokine analyses in cerebrospinal fluid (n=8) did not reveal major changes. Significant and clinically important improvements were found in fatigue (p=0.001) and health-related quality of life (p=0.004). Measures of mood (p=0.002), muscle strength (p ≤ 0.001), walking speed (p=0.013) and cognition (p=0.04) were also improved. A majority of participants evaluated the training as very good and perceived changes to the better. High-intensity resistance training in persons with relapsing remitting multiple sclerosis with low disability had positive effects on peripheral pro-inflammatory cytokine levels, led to clinically relevant improvements in measures of fatigue and health-related quality of life, and was well tolerated. These results provide a basis for a larger randomized trial. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Measuring Gas Concentration and Wind Intensity in a Turbulent Wind Tunnel with a Mobile Robot

    Directory of Open Access Journals (Sweden)

    Dani Martínez

    2016-01-01

    Full Text Available This paper presents the measurement of gas concentration and wind intensity performed with a mobile robot in a custom turbulent wind tunnel designed for experimentation with customizable wind and gas leak sources. This paper presents the representation in different information layers of the measurements obtained in the turbulent wind tunnel under different controlled environmental conditions in order to describe the plume of the gas and wind intensities inside the experimentation chamber. The information layers have been generated from the measurements gathered by individual onboard gas and wind sensors carried out by an autonomous mobile robot. On the one hand, the assumption was that the size and cost of these specialized sensors do not allow the creation of a net of sensors or other measurement alternatives based on the simultaneous use of several sensors, and on the other hand, the assumption is that the information layers created will have application on the development and test of automatic gas source location procedures based on reactive or nonreactive algorithms.

  17. Diode readout electronics for beam intensity and position monitors for FELs

    International Nuclear Information System (INIS)

    Herrmann, S; Hart, P; Freytag, M; Pines, J; Weaver, M; Sapozhnikov, L; Nelson, S; Koglin, J; Carini, G A; Tomada, A; Haller, G

    2014-01-01

    LCLS uses Intensity-Position Monitors (IPM) to measure intensity and position of the FEL x-ray pulses. The primary beam passes through a silicon nitride film and four diodes, arranged in quadrants, detect the backscattered x-ray photons. The position is derived from the relative intensity of the four diodes, while the sum provides beam intensity information. In contrast to traditional synchrotron beam monitors, where diodes measure a DC current signal, the LCLS beam monitors have to cope with the pulsed nature of the FEL, which requires a large single shot dynamic range. A key component of these beam monitors is the readout electronics. The first generation of beam monitors showed some limitations. A new scheme with upgraded electronics, firmware and software was implemented resulting in a more robust and reliable measuring tool.

  18. Effect of high-intensity statin therapy on atherosclerosis in non-infarct-related coronary arteries (IBIS-4)

    DEFF Research Database (Denmark)

    Räber, Lorenz; Taniwaki, Masanori; Zaugg, Serge

    2015-01-01

    AIM: The effect of long-term high-intensity statin therapy on coronary atherosclerosis among patients with acute ST-segment elevation myocardial infarction (STEMI) is unknown. The aim of this study was to quantify the impact of high-intensity statin therapy on plaque burden, composition, and phen......AIM: The effect of long-term high-intensity statin therapy on coronary atherosclerosis among patients with acute ST-segment elevation myocardial infarction (STEMI) is unknown. The aim of this study was to quantify the impact of high-intensity statin therapy on plaque burden, composition......-infarct-related epicardial coronary arteries (non-IRA) after successful primary PCI. Patients were treated with high-intensity rosuvastatin (40 mg/day) throughout 13 months and serial intracoronary imaging with the analysis of matched segments was available for 82 patients with 146 non-IRA. The primary IVUS end...

  19. Measuring the quality of therapeutic apheresis care in the pediatric intensive care unit.

    Science.gov (United States)

    Sussmane, Jeffrey B; Torbati, Dan; Gitlow, Howard S

    2012-01-01

    Our goal was to measure the quality of care provided in the Pediatric Intensive Care Unit (PICU) during Therapeutic Apheresis (TA). We described the care as a step by step process. We designed a flow chart to carefully document each step of the process. We then defined each step with a unique clinical indictor (CI) that represented the exact task we felt provided quality care. These CIs were studied and modified for 1 year. We measured our performance in this process by the number of times we accomplished the CI vs. the total number of CIs that were to be performed. The degree of compliance, with these clinical indicators, was analyzed and used as a metric for quality by calculating how close the process is running exactly as planned or "in control." The Apheresis Process was in control (compliance) for 47% of the indicators, as measured in the aggregate for the first observational year. We then applied the theory of Total Quality Management (TQM) through our Design, Measure, Analyze, Improve, and Control (DMAIC) model. We were able to improve the process and bring it into control by increasing the compliance to > 99.74%, in the aggregate, for the third and fourth quarter of the second year. We have implemented TQM to increase compliance, thus control, of a highly complex and multidisciplinary Pediatric Intensive Care therapy. We have shown a reproducible and scalable measure of quality for a complex clinical process in the PICU, without additional capital expenditure. Copyright © 2011 Wiley-Liss, Inc.

  20. Relating Solar Energetic Particle Event Fluences to Peak Intensities

    Science.gov (United States)

    Kahler, Stephen W.; Ling, Alan G.

    2018-02-01

    Recently we (Kahler and Ling, Solar Phys. 292, 59, 2017: KL) have shown that time-intensity profiles [I(t)] of 14 large solar energetic particle (SEP) events can be fitted with a simple two-parameter fit, the modified Weibull function, which is characterized by shape and scaling parameters [α and β]. We now look for a simple correlation between an event peak energy intensity [Ip] and the time integral of I(t) over the event duration: the fluence [F]. We first ask how the ratio of F/Ip varies for the fits of the 14 KL events and then examine that ratio for three separate published statistical studies of SEP events in which both F and Ip were measured for comparisons of those parameters with various solar-flare and coronal mass ejection (CME) parameters. The three studies included SEP energies from a 4 - 13 MeV band to E > 100 MeV. Within each group of SEP events, we find a very robust correlation (CC > 0.90) in log-log plots of F versus Ip over four decades of Ip. The ratio increases from western to eastern longitudes. From the value of Ip for a given event, F can be estimated to within a standard deviation of a factor of {≤} 2. Log-log plots of two studies are consistent with slopes of unity, but the third study shows plot slopes of { 10 MeV to {>} 100 MeV. This difference is not explained.

  1. TMS effects on subjective and objective measures of vision: stimulation intensity and pre- versus post-stimulus masking.

    Science.gov (United States)

    de Graaf, Tom A; Cornelsen, Sonja; Jacobs, Christianne; Sack, Alexander T

    2011-12-01

    Transcranial magnetic stimulation (TMS) can be used to mask visual stimuli, disrupting visual task performance or preventing visual awareness. While TMS masking studies generally fix stimulation intensity, we hypothesized that varying the intensity of TMS pulses in a masking paradigm might inform several ongoing debates concerning TMS disruption of vision as measured subjectively versus objectively, and pre-stimulus (forward) versus post-stimulus (backward) TMS masking. We here show that both pre-stimulus TMS pulses and post-stimulus TMS pulses could strongly mask visual stimuli. We found no dissociations between TMS effects on the subjective and objective measures of vision for any masking window or intensity, ruling out the option that TMS intensity levels determine whether dissociations between subjective and objective vision are obtained. For the post-stimulus time window particularly, we suggest that these data provide new constraints for (e.g. recurrent) models of vision and visual awareness. Finally, our data are in line with the idea that pre-stimulus masking operates differently from conventional post-stimulus masking. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Intensity measurements of slowly extracted heavy ion beams from the SIS

    International Nuclear Information System (INIS)

    Heeg, P.; Peters, A.; Strehl, P.

    1994-11-01

    The paper reports about performance tests of newly designed Secondary Electron Monitors (SEM), Ionization Chambers (IC) and Multi Diode Counters (MDC). Especially the linearity of the detectors with respect to the specific energy loss will be discussed. Calibration has been performed by means of scintillation particle counters at the lower end of the intensity region. The status of the Cryogenic Current Comparator (CCC), which is provided for absolute measurements and calibration of detectors above some nA of beam current is reported, too. (orig.)

  3. Occupational Variation in End-of-Life Care Intensity.

    Science.gov (United States)

    Hyder, Joseph A; Haring, R Sterling; Sturgeon, Daniel; Gazarian, Priscilla K; Jiang, Wei; Cooper, Zara; Lipsitz, Stuart R; Prigerson, Holly G; Weissman, Joel S

    2018-03-01

    End-of-life (EOL) care intensity is known to vary by secular and geographic patterns. US physicians receive less aggressive EOL care than the general population, presumably the result of preferences shaped by work-place experience with EOL care. We investigated occupation as a source of variation in EOL care intensity. Across 4 states, we identified 660 599, nonhealth maintenance organization Medicare beneficiaries aged ≥66 years who died between 2004 and 2011. Linking death certificates, we identified beneficiaries with prespecified occupations: nurses, farmers, clergy, mortuary workers, homemakers, first-responders, veterinary workers, teachers, accountants, and the general population. End-of-life care intensity over the last 6 months of life was assessed using 5 validated measures: (1) Medicare expenditures, rates of (2) hospice, (3) surgery, (4) intensive care, and (5) in-hospital death. Occupation was a source of large variation in EOL care intensity across all measures, before and after adjustment for sex, education, age-adjusted Charlson Comorbidity Index, race/ethnicity, and hospital referral region. For example, absolute and relative adjusted differences in expenditures were US$9991 and 42% of population mean expenditure ( P EOL care intensity measures, teachers (5 of 5), homemakers (4 of 5), farmers (4 of 5), and clergy (3 of 5) demonstrated significantly less aggressive care. Mortuary workers had lower EOL care intensity (4 of 5) but small numbers limited statistical significance. Occupations with likely exposure to child development, death/bereavement, and naturalistic influences demonstrated lower EOL care intensity. These findings may inform patients and clinicians navigating choices around individual EOL care preferences.

  4. Performance and burnout in intensive care units

    NARCIS (Netherlands)

    Keijsers, GJ; Schaufeli, WB; LeBlanc, P; Zwerts, C; Miranda, DR

    1995-01-01

    The relationship between three different performance measures and burnout was explored in 20 Dutch Intensive Care Units (ICUs). Burnout (i.e. emotional exhaustion and depersonalization) proved to be significantly related to nurses' perceptions of performance as well as to objectively assessed unit

  5. Measurement of the intensity of the cosmic background radiation at 3.0 cm

    International Nuclear Information System (INIS)

    Friedman, S.D.

    1984-01-01

    The intensity of the cosmic background radiation (CBR) has been measured at a wavelength of 3.0 cm as part of a program to measure th Rayleigh-Jeans spectrum of the CBR at five wavelengths between 0.33 cm and 12 cm. The instrument used is a dual-antenna Dicke-switched radiometer with a double-sideband noise temperature of 490 K and a sensitivity of 46 mK/Hz/sup 1/2/. The entire radiometer is mounted on bearings. The atmospheric emission was measured by rotating the radiometer, and thus directing one antenna to zenith angles of +- 30 0 and +- 40 0 . 61 references, 24 figures, 18 tables

  6. Relative importance of precipitation frequency and intensity in inter-annual variation of precipitation in Singapore during 1980-2013

    Science.gov (United States)

    Li, Xin; Babovic, Vladan

    2017-04-01

    Observed studies on inter-annual variation of precipitation provide insight into the response of precipitation to anthropogenic climate change and natural climate variability. Inter-annual variation of precipitation results from the concurrent variations of precipitation frequency and intensity, understanding of the relative importance of frequency and intensity in the variability of precipitation can help fathom its changing properties. Investigation of the long-term changes of precipitation schemes has been extensively carried out in many regions across the world, however, detailed studies of the relative importance of precipitation frequency and intensity in inter-annual variation of precipitation are still limited, especially in the tropics. Therefore, this study presents a comprehensive framework to investigate the inter-annual variation of precipitation and the dominance of precipitation frequency and intensity in a tropical urban city-state, Singapore, based on long-term (1980-2013) daily precipitation series from 22 rain gauges. First, an iterative Mann-Kendall trend test method is applied to detect long-term trends in precipitation total, frequency and intensity at both annual and seasonal time scales. Then, the relative importance of precipitation frequency and intensity in inducing the inter-annual variation of wet-day precipitation total is analyzed using a dominance analysis method based on linear regression. The results show statistically significant upward trends in wet-day precipitation total, frequency and intensity at annual time scale, however, these trends are not evident during the monsoon seasons. The inter-annual variation of wet-day precipitation is mainly dominated by precipitation intensity for most of the stations at annual time scale and during the Northeast monsoon season. However, during the Southwest monsoon season, the inter-annual variation of wet-day precipitation is mainly dominated by precipitation frequency. These results have

  7. Effective line intensity measurements of trans-nitrous acid (HONO) of the ν1 band near 3600 cm-1 using laser difference-frequency spectrometer

    Science.gov (United States)

    Maamary, Rabih; Fertein, Eric; Fourmentin, Marc; Dewaele, Dorothée; Cazier, Fabrice; Chen, Changshui; Chen, Weidong

    2017-07-01

    We report on the measurements of the effective line intensities of the ν1 fundamental band of trans-nitrous acid (trans-HONO) in the infrared near 3600 cm-1 (2.78 μm). A home-made widely tunable laser spectrometer based on difference-frequency generation (DFG) was used for this study. The strengths of 28 well-resolved absorption lines of the ν1 band were determined by scaling their absorption intensities to the well referenced absorption line intensity of the ν3 band of trans-HONO around 1250 cm-1 recorded simultaneously with the help of a DFB quantum cascade laser (QCL) spectrometer. The maximum measurement uncertainty of 12% in the line intensities is mainly determined by the uncertainty announced in the referenced line intensities, while the measurement precision in frequency positions of the absorption lines is better than 6×10-4 cm-1. The cross-measurement carried out in the present work allows one to perform intensity calibration using well referenced line parameters.

  8. Correlation of Neonatal Intensive Care Unit Performance Across Multiple Measures of Quality of Care

    Science.gov (United States)

    Profit, J; Zupancic, JAF; Gould, JB; Pietz, K; Kowalkowski, MA; Draper, D; Hysong, SJ; Petersen, LA

    2014-01-01

    Objectives To examine whether high performance on one measure of quality is associated with high performance on others and to develop a data-driven explanatory model of neonatal intensive care unit (NICU) performance. Design We conducted a cross-sectional data analysis of a statewide perinatal care database. Risk-adjusted NICU ranks were computed for each of 8 measures of quality selected based on expert input. Correlations across measures were tested using the Pearson correlation coefficient. Exploratory factor analysis was used to determine whether underlying factors were driving the correlations. Setting Twenty-two regional NICUs in California. Patients In total, 5445 very low-birth-weight infants cared for between January 1, 2004, and December 31, 2007. Main Outcomes Measures Pneumothorax, growth velocity, health care–associated infection, antenatal corticosteroid use, hypothermia during the first hour of life, chronic lung disease, mortality in the NICU, and discharge on any human breast milk. Results The NICUs varied substantially in their clinical performance across measures of quality. Of 28 unit-level correlations only 6 were significant (P quality measures were strong (ρ > .5) for 1 pair, moderate (.3 quality in this sample. Pneumothorax, mortality in the NICU, and antenatal corticosteroid use loaded on factor 1; growth velocity and health care–associated infection loaded on factor 2; chronic lung disease loaded on factor 3; and discharge on any human breast milk loaded on factor 4. Conclusion In this sample, the ability of individual measures of quality to explain overall quality of neonatal intensive care was modest. PMID:23403539

  9. Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients.

    Science.gov (United States)

    Asadian, Simin; Khatony, Alireza; Moradi, Gholamreza; Abdi, Alireza; Rezaei, Mansour

    2016-01-01

    An accurate determination of body temperature in critically ill patients is a fundamental requirement for initiating the proper process of diagnosis, and also therapeutic actions; therefore, the aim of the study was to assess the accuracy and precision of four noninvasive peripheral methods of temperature measurement compared to the central nasopharyngeal measurement. In this observational prospective study, 237 patients were recruited from the intensive care unit of Imam Ali Hospital of Kermanshah. The patients' body temperatures were measured by four peripheral methods; oral, axillary, tympanic, and forehead along with a standard central nasopharyngeal measurement. After data collection, the results were analyzed by paired t-test, kappa coefficient, receiver operating characteristic curve, and using Statistical Package for the Social Sciences, version 19, software. There was a significant meaningful correlation between all the peripheral methods when compared with the central measurement (Ptemperatures of right and left tympanic membranes and the standard central nasopharyngeal measurement (88%). Paired t-test demonstrated an acceptable precision with forehead (P=0.132), left (P=0.18) and right (P=0.318) tympanic membranes, oral (P=1.00), and axillary (P=1.00) methods. Sensitivity and specificity of both the left and right tympanic membranes were more than for other methods. The tympanic and forehead methods had the highest and lowest accuracy for measuring body temperature, respectively. It is recommended to use the tympanic method (right and left) for assessing a patient's body temperature in the intensive care units because of high accuracy and acceptable precision.

  10. An Industrial Radipgraphy Exposure Device Based on Measurement of Transmitted Gamma-Ray Intensity

    International Nuclear Information System (INIS)

    Polee, C.; Chankow, N.; Srisatit, S.; Thong-Aram, D.

    2014-01-01

    In film radiography, underexposure and overexposure may happen particularly when lacking knowledge of specimen material and hollowness. This paper describes a method and a device for determining exposure in industrial gamma-ray radiography based on quick measurement of transmitted gamma-ray intensity with a D3372 Hamamatsu small GM tube. Application software is developed for Android mobile phone to remotely control the device and to display the counting data via Bluetooth. Prior to placing film, the device is placed behind the specimen to be radiographed to determine the exposure time from the transmitted intensity which is independent on source activity, source-to-film distance, specimen thickness and kind of material. The developed technique and device make radiographic process economic, convenient and more reliable.

  11. Adaptive pixel-to-pixel projection intensity adjustment for measuring a shiny surface using orthogonal color fringe pattern projection

    Science.gov (United States)

    Chen, Chao; Gao, Nan; Wang, Xiangjun; Zhang, Zonghua

    2018-05-01

    Three-dimensional (3D) shape measurement based on fringe pattern projection techniques has been commonly used in various fields. One of the remaining challenges in fringe pattern projection is that camera sensor saturation may occur if there is a large range of reflectivity variation across the surface that causes measurement errors. To overcome this problem, a novel fringe pattern projection method is proposed to avoid image saturation and maintain high-intensity modulation for measuring shiny surfaces by adaptively adjusting the pixel-to-pixel projection intensity according to the surface reflectivity. First, three sets of orthogonal color fringe patterns and a sequence of uniform gray-level patterns with different gray levels are projected onto a measured surface by a projector. The patterns are deformed with respect to the object surface and captured by a camera from a different viewpoint. Subsequently, the optimal projection intensity at each pixel is determined by fusing different gray levels and transforming the camera pixel coordinate system into the projector pixel coordinate system. Finally, the adapted fringe patterns are created and used for 3D shape measurement. Experimental results on a flat checkerboard and shiny objects demonstrate that the proposed method can measure shiny surfaces with high accuracy.

  12. A Time Difference Method for Measurement of Phase Shift between Distributed Feedback Laser Diode (DFB-LD Output Wavelength and Intensity

    Directory of Open Access Journals (Sweden)

    Yongning Liu

    2015-07-01

    Full Text Available A time difference method to conveniently measure the phase shift between output wavelength and intensity of distributed feedback laser diodes (DFB-LDs was proposed. This approach takes advantage of asymmetric absorption positions at the same wavelength during wavelength increase and decrease tuning processes in the intensity-time curve by current modulation. For its practical implementation, a measurement example of phase shift was demonstrated by measuring a time difference between the first time and the second time attendances of the same gas absorption line in the intensity-time curve during one sine or triangle modulation circle. The phase shifts at modulation frequencies ranging from 50 Hz to 50 kHz were measured with a resolution of 0.001π. As the modulation frequency increased the shift value increased with a slowed growth rate.

  13. Experimental evaluation of rigor mortis. VIII. Estimation of time since death by repeated measurements of the intensity of rigor mortis on rats.

    Science.gov (United States)

    Krompecher, T

    1994-10-21

    The development of the intensity of rigor mortis was monitored in nine groups of rats. The measurements were initiated after 2, 4, 5, 6, 8, 12, 15, 24, and 48 h post mortem (p.m.) and lasted 5-9 h, which ideally should correspond to the usual procedure after the discovery of a corpse. The experiments were carried out at an ambient temperature of 24 degrees C. Measurements initiated early after death resulted in curves with a rising portion, a plateau, and a descending slope. Delaying the initial measurement translated into shorter rising portions, and curves initiated 8 h p.m. or later are comprised of a plateau and/or a downward slope only. Three different phases were observed suggesting simple rules that can help estimate the time since death: (1) if an increase in intensity was found, the initial measurements were conducted not later than 5 h p.m.; (2) if only a decrease in intensity was observed, the initial measurements were conducted not earlier than 7 h p.m.; and (3) at 24 h p.m., the resolution is complete, and no further changes in intensity should occur. Our results clearly demonstrate that repeated measurements of the intensity of rigor mortis allow a more accurate estimation of the time since death of the experimental animals than the single measurement method used earlier. A critical review of the literature on the estimation of time since death on the basis of objective measurements of the intensity of rigor mortis is also presented.

  14. Bringing quality improvement into the intensive care unit.

    Science.gov (United States)

    McMillan, Tracy R; Hyzy, Robert C

    2007-02-01

    During the last several years, many governmental and nongovernmental organizations have championed the application of the principles of quality improvement to the practice of medicine, particularly in the area of critical care. To review the breadth of approaches to quality improvement in the intensive care unit, including measures such as mortality and length of stay, and the use of protocols, bundles, and the role of large, multiple-hospital collaboratives. Several agencies have participated in the application of the quality movement to medicine, culminating in the development of standards such as the intensive care unit core measures of the Joint Commission on Accreditation of Healthcare Organizations. Although "zero defects" may not be possible in all measurable variables of quality in the intensive care unit, several measures, such as catheter-related bloodstream infections, can be significantly reduced through the implementation of improved processes of care, such as care bundles. Large, multiple-center, quality improvement collaboratives, such as the Michigan Keystone Intensive Care Unit Project, may be particularly effective in improving the quality of care by creating a "bandwagon effect" within a geographic region. The quality revolution is having a significant effect in the critical care unit and is likely to be facilitated by the transition to the electronic medical record.

  15. Vertical muon intensity measured with MACRO at the Gran Sasso laboratory

    International Nuclear Information System (INIS)

    Ambrosio, M.; Antolini, R.; Auriemma, G.; Baker, R.; Baldini, A.; Barbarino, G.C.; Barish, B.C.; Battistoni, G.; Bellotti, R.; Bemporad, C.; Bernardini, P.; Bilokon, H.; Bisi, V.; Bloise, C.; Bower, C.; Bussino, S.; Cafagna, F.; Calicchio, M.; Campana, D.; Carboni, M.; Castellano, M.; Cecchini, S.; Cei, F.; Celio, P.; Chiarella, V.; Corona, A.; Coutu, S.; De Cataldo, G.; Dekhissi, H.; De Marzo, C.; De Mitri, I.; De Vincenzi, M.; Di Credico, A.; Erriquez, O.; Favuzzi, C.; Forti, C.; Fusco, P.; Giacomelli, G.; Giannini, G.; Giglietto, N.; Grassi, M.; Grillo, A.; Guarino, F.; Guarnaccia, P.; Gustavino, C.; Habig, A.; Hanson, K.; Hawthorne, A.; Heinz, R.; Hong, J.T.; Iarocci, E.; Katsavounidis, E.; Kearns, E.; Kyriazopoulou, S.; Lamanna, E.; Lane, C.; Levin, D.S.; Lipari, P.; Liu, R.; Longley, N.P.; Longo, M.J.; Lu, Y.; Ludlam, G.; Mancarella, G.; Mandrioli, G.; Margiotta-Neri, A.; Marini, A.; Martello, D.; Marzari-Chiesa, A.; Mazziotta, M.N.; Michael, D.G.; Mikheyev, S.; Miller, L.; Mittelbrunn, M.; Monacelli, P.; Montaruli, T.; Monteno, M.; Mufson, S.; Musser, J.; Nicolo, D.; Nolty, R.; Okada, C.; Orth, C.; Osteria, G.; Palamara, O.; Parlati, S.; Patera, V.; Patrizii, L.; Pazzi, R.; Peck, C.W.; Petrera, S.; Pignatano, N.D.; Pistilli, P.; Popa, V.; Raino, A.; Reynoldson, J.; Ronga, F.; Sanzgiri, A.; Sartogo, F.; Satriano, C.; Satta, L.; Scapparone, E.; Scholberg, K.; Sciubba, A.; Serra-Lugaresi, P.; Severi, M.; Sitta, M.; Spinelli, P.; Spinetti, M.; Spurio, M.; Steinberg, R.; Stone, J.L.; Sulak, L.R.; Surdo, A.; Tarle, G.; Tassoni, F.; Togo, V.; Valente, V.; Walter, C.W.; Webb, R.

    1995-01-01

    The vertical underground muon intensity has been measured in the slant depth range 3200--7000 hg cm -2 (standard rock) with the completed lower part of the MACRO detector at the Gran Sasso laboratory, using a large sample of data. These observations are used to compute the surface muon flux and the primary ''all-nucleon'' spectrum. An analysis of systematic uncertainties introduced by the interaction models in the atmosphere and the underground propagation of muons is presented. A comparison of our results with published data is also presented

  16. Measured electric field intensities near electric cloud discharges detected by the Kennedy Space Center's Lightning Detection and Ranging System, LDAR

    Science.gov (United States)

    Poehler, H. A.

    1977-01-01

    For a summer thunderstorm, for which simultaneous, airborne electric field measurements and Lightning Detection and Ranging (LDAR) System data was available, measurements were coordinated to present a picture of the electric field intensity near cloud electrical discharges detected by the LDAR System. Radar precipitation echos from NOAA's 10 cm weather radar and measured airborne electric field intensities were superimposed on LDAR PPI plots to present a coordinated data picture of thunderstorm activity.

  17. Analog measurement of delayed antiproton annihilation time spectra in a high intensity pulsed antiproton beam

    International Nuclear Information System (INIS)

    Niestroj, A.; Hayano, R.S.; Ishikawa, T.; Tamura, H.; Torii, H.A.; Morita, N.; Yamazaki, T.; Sugai, I.; Nakayoshi, K.; Horvath, D.; Eades, J.; Widmann, E.

    1996-01-01

    An analog detection system has been developed to measure delayed antiproton annihilation time spectra for laser resonance spectroscopy of metastable antiprotonic helium atoms using the high-intensity pulsed beam of antiprotons from LEAR at CERN. (orig.)

  18. Determination of crystal structures with large known fragments directly from measured X-ray powder diffraction intensities

    International Nuclear Information System (INIS)

    Rius, J.; Miravitlles, C.

    1988-01-01

    A strategy for the determination of crystal structures with large known fragments directly from measured X-ray powder diffraction intensities is presented. It is based on the automated full-symmetry Patterson search method described by Rius and Miravitlles where the Fourier coefficients of the observed Patterson function are modified to allow the use of powder diffraction intensity data. Its application to two structures, one with simulated and one with experimental data, is shown. (orig.)

  19. Self-regulatory mode (locomotion and assessment), well-being (subjective and psychological), and exercise behavior (frequency and intensity) in relation to high school pupils' academic achievement.

    Science.gov (United States)

    Garcia, Danilo; Jimmefors, Alexander; Mousavi, Fariba; Adrianson, Lillemor; Rosenberg, Patricia; Archer, Trevor

    2015-01-01

    Background. Self-regulation is the procedure implemented by an individual striving to reach a goal and consists of two inter-related strategies: assessment and locomotion. Moreover, both subjective and psychological well-being along exercise behaviour might also play a role on adolescents academic achievement. Method. Participants were 160 Swedish high school pupils (111 boys and 49 girls) with an age mean of 17.74 (sd = 1.29). We used the Regulatory Mode Questionnaire to measure self-regulation strategies (i.e., locomotion and assessment). Well-being was measured using Ryff's Psychological Well-Being Scales short version, the Temporal Satisfaction with Life Scale, and the Positive Affect and Negative Affect Schedule. Exercise behaviour was self-reported using questions pertaining to frequency and intensity of exercise compliance. Academic achievement was operationalized through the pupils' mean value of final grades in Swedish, Mathematics, English, and Physical Education. Both correlation and regressions analyses were conducted. Results. Academic achievement was positively related to assessment, well-being, and frequent/intensive exercise behaviour. Assessment was, however, negatively related to well-being. Locomotion on the other hand was positively associated to well-being and also to exercise behaviour. Conclusions. The results suggest a dual (in)direct model to increase pupils' academic achievement and well-being-assessment being directly related to higher academic achievement, while locomotion is related to frequently exercising and well-being, which in turn, increase academic achievement.

  20. Assimilation and water relations of dryland castor at different intensities of solar radiation

    International Nuclear Information System (INIS)

    Balasubramanian, V.; Venkateswarlu, S.

    1995-01-01

    Primary racemes of dryland castor develop during later part of rainy season and secondaries and tertiaries develop during post-rainy season. The reproductive phase is therefore subjected to variation in soil moisture availability and solar radiation intensity. The objective of the study was to find out the influence of fluctuation in solar radiation intensity on photosynthetic rate, transpiration rate, transpiration efficiency, stomatal conductance and leaf water potential during early and late reproductive phase of castor. When photosynthetically active radiation was less than 1000 mu-mol m-2s-1, transpiration efficiency decreased because reduction in photosynthesis rate was more than that in transpiration rate. Transpiration efficiency also decreased, when radiation was above 1500 mu-mol m-2s-1 because of increase only in transpiration rate. Leaf water potential was higher during early than during late reproductive phase at similar radiation intensity. Transpiration rate was lower and transpiration efficiency was more during early phase when radiation was above 1500 mu-mol m-2s-1. Photosynthetically active radiation and leaf water potential were inversely related

  1. Development of a screening measure of stress for parents of children hospitalised in a Paediatric Intensive Care Unit.

    Science.gov (United States)

    Rodríguez-Rey, Rocío; Alonso-Tapia, Jesús

    2016-08-01

    Having a child admitted to intensive care is a highly stressful experience for parents; however there is a lack of screening instruments of parental stress in that context, which would be useful for both, research and clinical purposes. (1) To validate a brief measure of parental stress based on the Parental Stressor Scale: Paediatric Intensive Care Unit (PSS:PICU), (2) to study which environmental factors of the PICU are more stressful in a sample of Spanish parents, and (3) to study which variables are related to higher levels of stress among this group. 196 Spanish parents completed the Abbreviated PSS: PICU (A-PSS:PICU) and a general stress scale (the Perceived Stress Scale) upon their child's discharge to test the convergent validity of the tool. Three months later, they were assessed anxiety and depression using the Hospital Anxiety and Depression Scale, and posttraumatic stress with the Davidson Trauma Scale in order to test the predictive validity of the A-PSS:PICU. Two factors emerged from Confirmatory Factor Analyses, (1) stress due to child's condition and (2) stress related to PICU's staff. The A-PSS:PICU showed adequate reliability and convergent and predictive validity. The most stressful aspects were the behaviours and emotional responses of their child and the loss of their parental role. Age, gender, child's condition, length of admission, spiritual beliefs, and mechanical ventilation were associated to parental stress scores. The A-PSS:PICU is a reliable and valid measure. Parental stress should be screened during a child's PICU admission to identify parents at risk of post-discharge distress. Copyright © 2016 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.

  2. Community regulation: the relative importance of recruitment and predation intensity of an intertidal community dominant in a seascape context.

    Directory of Open Access Journals (Sweden)

    Gil Rilov

    Full Text Available Predicting the strength and context-dependency of species interactions across multiple scales is a core area in ecology. This is especially challenging in the marine environment, where populations of most predators and prey are generally open, because of their pelagic larval phase, and recruitment of both is highly variable. In this study we use a comparative-experimental approach on small and large spatial scales to test the relationship between predation intensity and prey recruitment and their relative importance in shaping populations of a dominant rocky intertidal space occupier, mussels, in the context of seascape (availability of nearby subtidal reef habitat. Predation intensity on transplanted mussels was tested inside and outside cages and recruitment was measured with standard larval settlement collectors. We found that on intertidal rocky benches with contiguous subtidal reefs in New Zealand, mussel larval recruitment is usually low but predation on recruits by subtidal consumers (fish, crabs is intense during high tide. On nearby intertidal rocky benches with adjacent sandy subtidal habitats, larval recruitment is usually greater but subtidal predators are typically rare and predation is weaker. Multiple regression analysis showed that predation intensity accounts for most of the variability in the abundance of adult mussels compared to recruitment. This seascape-dependent, predation-recruitment relationship could scale up to explain regional community variability. We argue that community ecology models should include seascape context-dependency and its effects on recruitment and species interactions for better predictions of coastal community dynamics and structure.

  3. Community regulation: the relative importance of recruitment and predation intensity of an intertidal community dominant in a seascape context.

    Science.gov (United States)

    Rilov, Gil; Schiel, David R

    2011-01-01

    Predicting the strength and context-dependency of species interactions across multiple scales is a core area in ecology. This is especially challenging in the marine environment, where populations of most predators and prey are generally open, because of their pelagic larval phase, and recruitment of both is highly variable. In this study we use a comparative-experimental approach on small and large spatial scales to test the relationship between predation intensity and prey recruitment and their relative importance in shaping populations of a dominant rocky intertidal space occupier, mussels, in the context of seascape (availability of nearby subtidal reef habitat). Predation intensity on transplanted mussels was tested inside and outside cages and recruitment was measured with standard larval settlement collectors. We found that on intertidal rocky benches with contiguous subtidal reefs in New Zealand, mussel larval recruitment is usually low but predation on recruits by subtidal consumers (fish, crabs) is intense during high tide. On nearby intertidal rocky benches with adjacent sandy subtidal habitats, larval recruitment is usually greater but subtidal predators are typically rare and predation is weaker. Multiple regression analysis showed that predation intensity accounts for most of the variability in the abundance of adult mussels compared to recruitment. This seascape-dependent, predation-recruitment relationship could scale up to explain regional community variability. We argue that community ecology models should include seascape context-dependency and its effects on recruitment and species interactions for better predictions of coastal community dynamics and structure.

  4. Low-temperature relative reflectivity measurements of reflective and scintillating foils used in rare event searches

    Science.gov (United States)

    Langenkämper, A.; Ulrich, A.; Defay, X.; Feilitzsch, F. v.; Lanfranchi, J.-C.; Mondragón, E.; Münster, A.; Oppenheimer, C.; Potzel, W.; Roth, S.; Schönert, S.; Steiger, H.; Trinh Thi, H. H.; Wawoczny, S.; Willers, M.; Zöller, A.

    2018-03-01

    In this work we investigate the reflectivity of highly reflective multilayer polymer foils used in the CRESST experiment. The CRESST experiment searches directly for dark matter via operating scintillating CaWO4 crystals as targets for elastic dark matter-nucleon scattering. In order to suppress background events, the experiment employs the so-called phonon-light technique which is based on the simultaneous measurement of the heat signal in the main CaWO4 target crystal and of the emitted scintillation light with a separate cryogenic light detector. Both detectors are surrounded by a highly reflective and scintillating multilayer polymer foil to increase the light collection efficiency and to veto surface backgrounds. While this study is motivated by the CRESST experiment, the results are also relevant for other rare event searches using scintillating cryogenic bolometers in the field of the search of dark matter and neutrinoless double beta decay (0 νββ). In this work a dedicated experiment has been set up to determine the relative reflectivity at 300 K and 20 K of three multilayer foils ("VM2000", "VM2002", "Vikuiti") produced by the company 3M. The intensity of a light beam reflected off the foil is measured with a CCD camera. The ratio of the intensities at 300 K and 20 K corresponds to the relative reflectivity change. The measurements performed in this work show no variation of the reflectivity with temperature at a level of ∼1%.

  5. Incidence and factors related to delirium in an intensive care unit.

    Science.gov (United States)

    Mori, Satomi; Takeda, Juliana Rumy Tsuchihashi; Carrara, Fernanda Souza Angotti; Cohrs, Cibelli Rizzo; Zanei, Suely Sueko Viski; Whitaker, Iveth Yamaguchi

    2016-01-01

    To identify the incidence of delirium, compare the demographic and clinical characteristics of patients with and without delirium, and verify factors related to delirium in critical care patients. Prospective cohort with a sample made up of patients hospitalized in the Intensive Care Unit (ICU) of a university hospital. Demographic, clinical variables and evaluation with the Confusion Assessment Method for Intensive Care Unit to identify delirium were processed to the univariate analysis and logistic regression to identify factors related to the occurrence of delirium. Of the total 149 patients in the sample, 69 (46.3%) presented delirium during ICU stay, whose mean age, severity of illness and length of ICU stay were statistically higher. The factors related to delirium were: age, midazolam, morphine and propofol. Results showed high incidence of ICU delirium associated with older age, use of sedatives and analgesics, emphasizing the need for relevant nursing care to prevent and identify early, patients presenting these characteristics. Identificar a incidência de delirium, comparar as características demográficas e clínicas dos pacientes com e sem delirium e verificar os fatores relacionados ao delirium em pacientes internados em Unidade de Terapia Intensiva (UTI). Coorte prospectiva, cuja amostra foi constituída de pacientes internados em UTI de um hospital universitário. Variáveis demográficas, clínicas e da avaliação com o Confusion Assessment Method for Intensive Care Unit para identificação de delirium foram processadas para análise univariada, e regressão logística para identificar fatores relacionados à ocorrência do delirium. Do total de 149 pacientes da amostra, 69 (46,3%) apresentaram delirium durante a internação na UTI, observando-se que a média da idade, o índice de gravidade e o tempo de permanência nas UTI foram estatisticamente maiores. Os fatores relacionados ao delirium foram: idade, midazolam, morfina e propofol. Os

  6. Turbulence Intensity Scaling: A Fugue

    OpenAIRE

    Basse, Nils T.

    2018-01-01

    We study streamwise turbulence intensity definitions using smooth- and rough-wall pipe flow measurements made in the Princeton Superpipe. Scaling of turbulence intensity with the bulk (and friction) Reynolds number is provided for the definitions. The turbulence intensity is proportional to the square root of the friction factor with the same proportionality constant for smooth- and rough-wall pipe flow. Turbulence intensity definitions providing the best description of the measurements are i...

  7. European emissions trading and the international competitiveness of energy-intensive industries: a legal and political evaluation of possible supporting measures

    International Nuclear Information System (INIS)

    Asselt, H. van; Biermann, F.

    2007-01-01

    The EU Emissions Trading Directive is expected by European energy-intensive industries to harm their competitiveness vis-a-vis non-European competitors. Many additional measures have thus been proposed to 'level the playing field' and to protect the competitiveness of European energy-intensive industries within the larger effort of reducing Europe's greenhouse gas emissions and of meeting its obligations under the 1997 Kyoto Protocol. This article evaluates a range of proposed measures based on a set of political and legal criteria, including environmental effectiveness; the need to consider differentiated commitments, responsibilities and capabilities; conformity with world trade law and European Union law; and Europe's overall political interests. We discuss measures that could be adopted by the European Union and its member states, such as direct support for energy-intensive industries, restrictions of energy-intensive imports into the European Union through border cost adjustments, quotas or technical regulations, and cost reimbursement for affected developing countries. We also analyse measures available to multilateral institutions such as the United Nations Framework Convention on Climate Change and its Kyoto Protocol and the World Trade Organisation. We conclude with a classification of the discussed measures with red (unfeasible), yellow (potentially feasible) or green (feasible) labels. (author)

  8. European emissions trading and the international competitiveness of energy-intensive industries: a legal and political evaluation of possible supporting measures

    International Nuclear Information System (INIS)

    Asselt, Harro van; Biermann, Frank

    2007-01-01

    The EU Emissions Trading Directive is expected by European energy-intensive industries to harm their competitiveness vis-a-vis non-European competitors. Many additional measures have thus been proposed to 'level the playing field' and to protect the competitiveness of European energy-intensive industries within the larger effort of reducing Europe's greenhouse gas emissions and of meeting its obligations under the 1997 Kyoto Protocol. This article evaluates a range of proposed measures based on a set of political and legal criteria, including environmental effectiveness; the need to consider differentiated commitments, responsibilities and capabilities; conformity with world trade law and European Union law; and Europe's overall political interests. We discuss measures that could be adopted by the European Union and its member states, such as direct support for energy-intensive industries, restrictions of energy-intensive imports into the European Union through border cost adjustments, quotas or technical regulations, and cost reimbursement for affected developing countries. We also analyse measures available to multilateral institutions such as the United Nations Framework Convention on Climate Change and its Kyoto Protocol and the World Trade Organisation. We conclude with a classification of the discussed measures with red (unfeasible), yellow (potentially feasible) or green (feasible) labels

  9. MEASUREMENT OF QUENCHING INTENSITY, CALCULATION OF HEAT TRANSFER COEFFICIENT AND GLOBAL DATABASE OF LIQUID QUENCHANTS

    Directory of Open Access Journals (Sweden)

    Božidar Liščić

    2012-02-01

    Full Text Available This paper explains the need for a database of cooling intensities for liquid quenchants, in order to predict the quench hardness, microstructure, stresses and distortion, when real engineering components of complex geometry are quenched. The existing laboratory procedures for cooling intensity evaluation, using small test specimens, and Lumped-Heat-Capacity Method for calculation of heat transfer coefficient, are presented. Temperature Gradient Method for heat transfer calculation in workshop conditions, when using the Liscic/Petrofer probe, has been elaborated. Critical heat flux densities and their relation to the initial heat flux density, is explained. Specific facilities for testing quenching intensity in workshop conditions, are shown. The two phase project of the International Federation for Heat Treatment and Surface Engineering (IFHTSE, as recently approved, is mentioned.

  10. Transfer standard for the spectral density of relative intensity noise of optical fiber sources near 1550 nm

    International Nuclear Information System (INIS)

    Obarski, Gregory E.; Splett, Jolene D.

    2001-01-01

    We have developed a transfer standard for the spectral density of relative intensity noise (RIN) of optical fiber sources near 1550 nm. Amplified spontaneous emission (ASE) from an erbium-doped fiber amplifier (EDFA), when it is optically filtered over a narrow band (<5 nm), yields a stable RIN spectrum that is practically constant to several tens of gigahertz. The RIN is calculated from the power spectral density as measured with a calibrated optical spectrum analyzer. For a typical device it is -110 dB/Hz, with uncertainty ≤0.12 dB/Hz. The invariance of the RIN under attenuation yields a considerable dynamic range with respect to rf noise levels. Results are compared with those from a second method that uses a distributed-feedback laser (DFB) that has a Poisson-limited RIN. Application of each method to the same RIN measurement system yields frequency-dependent calibration functions that, when they are averaged, differ by ≤0.2 dB. [copyright] 2001 Optical Society of America

  11. Measurement of irradiation doses secondary to bedside radiographs in a medical intensive care unit

    Energy Technology Data Exchange (ETDEWEB)

    Boles, J M; Boussert, F; Manens, J P; Le Cam, B; Bellet, M; Garre, M

    1987-01-01

    The authors prospectively studied the radiation doses to radio-sensitive organs secondary to bedside radiographs in intensive care patients and in a control phantom. Dosimeters were taped on different organs during each bedside X-ray. The mean radiation doses, expressed in 10(-5) Gy (m-rad), for an ''average patient'' who was hospitalized 9 days and had 6 chest X-rays were respectively: 292 to the sternal bone marrow; 239 to the thyroid gland; 3 to the testes; 1 to the ovaries; 605 to the eye for 2 maxillary sinus X-rays. No diffused irradiation was measured during a 2-month period in the intensive care unit nor on dosimeters worn by four nurses.

  12. Measurement Of Ultrafast Ionisation From Intense Laser Interactions With Gas-Jets

    International Nuclear Information System (INIS)

    Gizzi, Leonida A.; Galimberti, Marco; Giulietti, Antonio; Giulietti, Danilo; Koester, Petra; Labate, Luca; Tomassini, Paolo; Martin, Philippe; Ceccotti, Tiberio; De Oliveira, Pascal; Monot, Pascal

    2006-01-01

    Interaction of an intense, ultrashort laser pulse with a gas-jet target is investigated through femtosecond optical interferometry to study the dynamics of ionization of the gas. Experimental results are presented in which the propagation of the pulse in the gas and the consequent plasma formation is followed step by step with high temporal and spatial resolution. We demonstrate that, combining the phase shift with the measurable depletion of fringe visibility associated with the transient change of refractive index in the ionizing region and taking into account probe travel time can provide direct information on gas ionization dynamics

  13. Intensive care delirium - effect on memories and health-related quality of life - a follow-up study

    DEFF Research Database (Denmark)

    Svenningsen, Helle; Tønnesen, Else K; Videbech, Poul

    2013-01-01

    after intensive care unit. Interviews were repeated after two and six months and supplemented with Short Form-36 and the Barthel Index. RESULTS: Delirium was detected in 60% of the patients in our study, and delirious patients had significantly fewer factual memories and more memories of delusion than...... than half of the patients in intensive care unit experience delirium, which is associated with fewer factual memories and more memories of delusions. Short Form-36 might not be sensitive to delirium-related outcomes. Future research should include the development of better assessment tools to determine...... the long-term consequences of intensive care unit delirium. RELEVANCE TO CLINICAL PRACTICE: We recommend regular assessment to prevent, detect and treat delirium. We also recommend an intensive care unit follow-up programme providing an opportunity for postintensive care unit patients, particularly...

  14. Alexithymia Is Related to the Need for More Emotional Intensity to Identify Static Fearful Facial Expressions

    Directory of Open Access Journals (Sweden)

    Francesca Starita

    2018-06-01

    Full Text Available Individuals with high levels of alexithymia, a personality trait marked by difficulties in identifying and describing feelings and an externally oriented style of thinking, appear to require more time to accurately recognize intense emotional facial expressions (EFEs. However, in everyday life, EFEs are displayed at different levels of intensity and individuals with high alexithymia may also need more emotional intensity to identify EFEs. Nevertheless, the impact of alexithymia on the identification of EFEs, which vary in emotional intensity, has largely been neglected. To address this, two experiments were conducted in which participants with low (LA and high (HA levels of alexithymia were assessed in their ability to identify static (Experiment 1 and dynamic (Experiment 2 morphed faces ranging from neutral to intense EFEs. Results showed that HA needed more emotional intensity than LA to identify static fearful – but not happy or disgusted – faces. On the contrary, no evidence was found that alexithymia affected the identification of dynamic EFEs. These results extend current literature suggesting that alexithymia is related to the need for more perceptual information to identify static fearful EFEs.

  15. Target micro-displacement measurement by a "comb" structure of intensity distribution in laser plasma propulsion

    Science.gov (United States)

    Zheng, Z. Y.; Zhang, S. Q.; Gao, L.; Gao, H.

    2015-05-01

    A "comb" structure of beam intensity distribution is designed and achieved to measure a target displacement of micrometer level in laser plasma propulsion. Base on the "comb" structure, the target displacement generated by nanosecond laser ablation solid target is measured and discussed. It is found that the "comb" structure is more suitable for a thin film target with a velocity lower than tens of millimeters per second. Combing with a light-electric monitor, the `comb' structure can be used to measure a large range velocity.

  16. Electron temperature measurement in Z-pinch

    International Nuclear Information System (INIS)

    Gerusov, A.V.; Orlov, M.M.; Terent'ev, A.R.; Khrabrov, V.A.

    1987-01-01

    Measurement of temperature of emitting plasma sheath in noncylindrical Z-pinch in neon at the stage of convergence to the axis, based on comparing the intensity of spectral lines belonging to Ne1, Ne2, is performed. Line intensity relation dependence was determined using calculations according to emitting-collision model. Spectra were recorded by electron-optical converter and relative intensity was determined by subsequent photometry of photolayer. Cylindric symmetrical MHD-calculations during which temperature and the observed line intensity relation were determined, are conducted

  17. Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for Column CO2 Measurements

    Science.gov (United States)

    Campbell, J. F.; Lin, B.; Obland, M. D.; Liu, Z.; Kooi, S. A.; Fan, T. F.; Nehrir, A. R.; Meadows, B.; Browell, E. V.

    2016-12-01

    Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for Column CO2 MeasurementsJoel F. Campbell1, Bing Lin1, Michael D. Obland1, Zhaoyan Liu1, Susan Kooi2, Tai-Fang Fan2, Amin R. Nehrir1, Byron Meadows1, Edward V. Browell31NASA Langley Research Center, Hampton, VA 23681 2SSAI, NASA Langley Research Center, Hampton, VA 23681 3STARSS-II Affiliate, NASA Langley Research Center, Hampton, VA 23681 AbstractGlobal and regional atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission and the Atmospheric Carbon and Transport (ACT) - America project are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity-Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space and airborne platforms to meet the ASCENDS and ACT-America science measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud returns. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby minimizing bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new sub-meter hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. These techniques are used in a new data processing

  18. Desensitizing Addiction: Using Eye Movements to Reduce the Intensity of Substance-Related Mental Imagery and Craving.

    Science.gov (United States)

    Littel, Marianne; van den Hout, Marcel A; Engelhard, Iris M

    2016-01-01

    Eye movement desensitization and reprocessing (EMDR) is an effective treatment for posttraumatic stress disorder. During this treatment, patients recall traumatic memories while making horizontal eye movements (EM). Studies have shown that EM not only desensitize negative memories but also positive memories and imagined events. Substance use behavior and craving are maintained by maladaptive memory associations and visual imagery. Preliminary findings have indicated that these mental images can be desensitized by EMDR techniques. We conducted two proof-of-principle studies to investigate whether EM can reduce the sensory richness of substance-related mental representations and accompanying craving levels. We investigated the effects of EM on (1) vividness of food-related mental imagery and food craving in dieting and non-dieting students and (2) vividness of recent smoking-related memories and cigarette craving in daily smokers. In both experiments, participants recalled the images while making EM or keeping eyes stationary. Image vividness and emotionality, image-specific craving and general craving were measured before and after the intervention. As a behavioral outcome measure, participants in study 1 were offered a snack choice at the end of the experiment. Results of both experiments showed that image vividness and craving increased in the control condition but remained stable or decreased after the EM intervention. EM additionally reduced image emotionality (experiment 2) and affected behavior (experiment 1): participants in the EM condition were more inclined to choose healthy over unhealthy snack options. In conclusion, these data suggest that EM can be used to reduce intensity of substance-related imagery and craving. Although long-term effects are yet to be demonstrated, the current studies suggest that EM might be a useful technique in addiction treatment.

  19. Developing and evaluating an instrument to measure Recovery After INtensive care: the RAIN instrument.

    Science.gov (United States)

    Bergbom, Ingegerd; Karlsson, Veronika; Ringdal, Mona

    2018-01-01

    Measuring and evaluating patients' recovery, following intensive care, is essential for assessing their recovery process. By using a questionnaire, which includes spiritual and existential aspects, possibilities for identifying appropriate nursing care activities may be facilitated. The study describes the development and evaluation of a recovery questionnaire and its validity and reliability. A questionnaire consisting of 30 items on a 5-point Likert scale was completed by 169 patients (103 men, 66 women), 18 years or older (m=69, SD 12.5) at 2, 6, 12 or 24 months following discharge from an ICU. An exploratory factor analysis, including a principal component analysis with orthogonal varimax rotation, was conducted. Ten initial items, with loadings below 0.40, were removed. The internal item/scale structure obtained in the principal component analysis was tested in relation to convergent and discrimination validity with a multi-trait analysis. Items consistency and reliability were assessed by Cronbach's alpha and internal item consistency. Test of scale quality, the proportion of missing values and respondents' scoring at maximum and minimum levels were also conducted. A total of 20 items in six factors - forward looking, supporting relations, existential ruminations, revaluation of life, physical and mental strength and need of social support were extracted with eigen values above one. Together, they explained 75% of the variance. The half-scale criterion showed that the proportion of incomplete scale scores ranged from 0% to 4.3%. When testing the scale's ability to differentiate between levels of the assessed concept, we found that the observed range of scale scores covered the theoretical range. Substantial proportions of respondents, who scored at the ceiling for forward looking and supporting relations and at floor for the need of social support, were found. These findings should be further investigated. The factor analysis, including discriminant validity

  20. Magnitude and Spatial Distribution of Impact Intensity Under the Foot Relates to Initial Foot Contact Pattern.

    Science.gov (United States)

    Breine, Bastiaan; Malcolm, Philippe; Segers, Veerle; Gerlo, Joeri; Derie, Rud; Pataky, Todd; Frederick, Edward C; De Clercq, Dirk

    2017-12-01

    In running, foot contact patterns (rear-, mid-, or forefoot contact) influence impact intensity and initial ankle and foot kinematics. The aim of the study was to compare impact intensity and its spatial distribution under the foot between different foot contact patterns. Forty-nine subjects ran at 3.2 m·s -1 over a level runway while ground reaction forces (GRF) and shoe-surface pressures were recorded and foot contact pattern was determined. A 4-zone footmask (forefoot, midfoot, medial and lateral rearfoot) assessed the spatial distribution of the vertical GRF under the foot. We calculated peak vertical instantaneous loading rate of the GRF (VILR) per foot zone as the impact intensity measure. Midfoot contact patterns were shown to have the lowest, and atypical rearfoot contact patterns the highest impact intensities, respectively. The greatest local impact intensity was mainly situated under the rear- and midfoot for the typical rearfoot contact patterns, under the midfoot for the atypical rearfoot contact patterns, and under the mid- and forefoot for the midfoot contact patterns. These findings indicate that different foot contact patterns could benefit from cushioning in different shoe zones.

  1. A spin-optoelectronic detector for the simultaneous measurement of the degree of circular polarization and intensity of a laser beam

    International Nuclear Information System (INIS)

    Khamari, Shailesh K.; Porwal, S.; Oak, S. M.; Sharma, T. K.

    2015-01-01

    Simultaneous measurement of the degree of circular polarization and intensity of a laser beam is essential in advanced photonic applications. However, it is not feasible with conventional helicity dependent detectors where an additional detector is needed to measure the intensity. Here, we report the development of a spin-optoelectronic detector that can measure the degree of circular polarization and the intensity of a laser beam simultaneously. The principle of operation of device is based on the two independent fundamental phenomena occurring in Au/InP hybrid structures, namely, Inverse Spin Hall Effect (ISHE) and the Photo-Voltaic (PV) Effect. The magnitude of ISHE and PV signals is simultaneously measured across the two pairs of contacts that are made on the top of device. No cross talk is observed between the two detectors made on the same chip. The all-electronic compact device is fast, operates at room temperature, and opens up the possibility of many applications in an integrated optoelectronic platform

  2. On the inversion problem of the plasma line intensity measurements in terms of photoelectron fluxes

    International Nuclear Information System (INIS)

    Lejeune, G.

    1979-01-01

    Assuming that the unidimensional distribution function of the photoelectron flux can be determined from plasma line intensity measurement, it is shown that the photoelectron flux distribution is not uniquely determined if additional hypotheses are not made. The limitations of the inversion procedure are shown: in particular, plasma line measurements cannot allow the determination of more than the first two Legendre components of the photoelectron flux. Experimental procedures for this determination are finally reviewed. (author)

  3. Measurements of neutron intensity from liquid deuterium moderator of the cold neutron source of KUR

    International Nuclear Information System (INIS)

    Kawai, Takeshi; Ebisawa, Toru; Akiyoshi, Tsunekazu; Tasaki, Seiji

    1990-01-01

    The neutron spectra from the liquid deuterium moderator of the cold neutron source of KUR were measured by the time of flight (TOF) method similar to the previous measurements for the liquid hydrogen moderator. The cold neutron gain factor is found to be about 20 ∼ 28 times for the wavelength longer than 6 A. Cold neutron intensities from the liquid deuterium moderator and from the liquid hydrogen moderator are compared and discussed. (author)

  4. Retention predictors related to intensive outpatient programs for substance use disorders.

    Science.gov (United States)

    Veach, L J; Remley, T P; Kippers, S M; Sorg, J D

    2000-08-01

    The purpose of this research was to expand knowledge in the current literature regarding treatment retention in intensive outpatient substance abuse treatment programs. The sample in this study participated in a hospital-based program accredited by the Joint Commission on Accreditation for Health Organizations (JCAHO) that utilized the Minnesota model. Specifically, this inquiry investigated whether treatment retention would be predicted by gender, age, employment status, number of problems on the treatment plan, whether the referral was related to driving while intoxicated (DWI), marital status, race, and whether each of the following substance problems was listed as the client's primary DSM-IV diagnosis: alcohol dependence, cocaine dependence, polysubstance dependence, opioid dependence, sedative/hypnotic dependence, cannabis dependence, other (or unknown) dependence, alcohol abuse, cannabis abuse, amphetamine abuse, and caffeine intoxication. Findings indicated that those retained in treatment, when compared to those who dropped out, had significantly more problems on their treatment plans, were more likely to be alcoholics, were less often cocaine addicts, and were more likely to be employed. The results of this study suggest that clients with this profile have increased likelihood of being retained in intensive outpatient substance abuse treatment programs.

  5. Low-cost vibration sensor based on dual fiber Bragg gratings and light intensity measurement.

    Science.gov (United States)

    Gao, Xueqing; Wang, Yongjiao; Yuan, Bo; Yuan, Yinquan; Dai, Yawen; Xu, Gang

    2013-09-20

    A vibration monitoring system based on light intensity measurement has been constructed, and the designed accelerometer is based on steel cantilever frame and dual fiber Bragg gratings (FBGs). By using numerical simulations for the dual FBGs, the dependence relationship of the area of main lobes on the difference of initial central wavelengths is obtained and the most optimal choice for the initial value and the vibration amplitude of the difference of central wavelengths of two FBGs is suggested. The vibration monitoring experiments are finished, and the measured data are identical to the simulated results.

  6. Effect of ranibizumab on high-speed indocyanine green angiography and minimum intensity projection optical coherence tomography findings in neovascular age-related macular degeneration.

    Science.gov (United States)

    Nicholson, Benjamin P; Nigam, Divya; Toy, Brian; Stetson, Paul F; Agrón, Elvira; Jacobs-El, Naima; Cunningham, Denise; Cukras, Catherine; Wong, Wai; Wiley, Henry; Chew, Emily; Ferris, Frederick; Meyerle, Catherine B

    2015-01-01

    The purpose of this 1-year prospective study was to investigate how induction/pro re nata ranibizumab intravitreal treatment of eyes with neovascular age-related macular degeneration affects the anatomy of choroidal neovascularization (CNV) and the overlying outer retinal tissue. High-speed indocyanine green (HS-ICG) angiography measurements provided quantification of the CNV size in 60 patients followed for 1 year. Minimum intensity projection optical coherence tomography (MinIP OCT), a novel algorithm assessing minimum optical intensity between the internal limiting membrane and retinal pigment epithelium, measured the area of outer retinal disruption overlying the CNV. Fluorescein angiography was also assessed to evaluate late retinal leakage. After 1 year, the mean area of CNV measured with indocyanine green angiography decreased by 5.8%. The mean area of MinIP OCT of outer retinal disruption overlying the CNV decreased by 4.2%. Mean area of fluorescein angiography leakage decreased by 6.3%. Both the area of outer retinal disruption measured with MinIP OCT and the area of leakage on fluorescein angiography typically exceeded the area of CNV on indocyanine green angiography at baseline and 1 year. Choroidal neovascularization treated with induction/pro re nata intravitreal ranibizumab for 1 year essentially remained static. Minimum intensity projection optical coherence tomography suggests that the area of outer retinal disruption overlying the CNV may be greater than the CNV itself and often correlates with the leakage area on fluorescein angiography. Additionally, there was minimal change in the area of outer retinal disruption on MinIP OCT even when fluid resolved. Measurements of the extent of CNV lesions based on indocyanine green angiography and MinIP OCT may provide useful outcome variables to help assess the CNV complex longitudinally and warrant further validation.

  7. Intensive Versus Distributed Aphasia Therapy: A Nonrandomized, Parallel-Group, Dosage-Controlled Study.

    Science.gov (United States)

    Dignam, Jade; Copland, David; McKinnon, Eril; Burfein, Penni; O'Brien, Kate; Farrell, Anna; Rodriguez, Amy D

    2015-08-01

    Most studies comparing different levels of aphasia treatment intensity have not controlled the dosage of therapy provided. Consequently, the true effect of treatment intensity in aphasia rehabilitation remains unknown. Aphasia Language Impairment and Functioning Therapy is an intensive, comprehensive aphasia program. We investigated the efficacy of a dosage-controlled trial of Aphasia Language Impairment and Functioning Therapy, when delivered in an intensive versus distributed therapy schedule, on communication outcomes in participants with chronic aphasia. Thirty-four adults with chronic, poststroke aphasia were recruited to participate in an intensive (n=16; 16 hours per week; 3 weeks) versus distributed (n=18; 6 hours per week; 8 weeks) therapy program. Treatment included 48 hours of impairment, functional, computer, and group-based aphasia therapy. Distributed therapy resulted in significantly greater improvements on the Boston Naming Test when compared with intensive therapy immediately post therapy (P=0.04) and at 1-month follow-up (P=0.002). We found comparable gains on measures of participants' communicative effectiveness, communication confidence, and communication-related quality of life for the intensive and distributed treatment conditions at post-therapy and 1-month follow-up. Aphasia Language Impairment and Functioning Therapy resulted in superior clinical outcomes on measures of language impairment when delivered in a distributed versus intensive schedule. The therapy progam had a positive effect on participants' functional communication and communication-related quality of life, regardless of treatment intensity. These findings contribute to our understanding of the effect of treatment intensity in aphasia rehabilitation and have important clinical implications for service delivery models. © 2015 American Heart Association, Inc.

  8. Long-term Modulation of Cosmic Ray Intensity in relation to Sunspot ...

    Indian Academy of Sciences (India)

    it should be more closely connected with cosmic ray modulation than with other solar characteristics (sunspot numbers or coronal emission intensity). The intensity of galactic cosmic rays varies inversely with sunspot numbers, having their maximum intensity at the minimum of the 11-year sunspot cycle (Forbush 1954, 1958) ...

  9. The use of a CCD imaging system for X-ray film intensity measurement

    International Nuclear Information System (INIS)

    Grigg, M.W.; Barnea, Z.

    1994-01-01

    The use of a simple CCD-based imaging system for digitizing and x-ray film image is demonstrated. A method of extending the region of linear response of the film based upon an analytic representation of the observed response to a series of increasing exposures is described. The validity of the procedure is illustrated through an example of the absolute intensity measurement of a reflection of cadmium sulphide. 3 refs., 7 figs

  10. Passive coherent discriminator using phase diversity for the simultaneous measurement of frequency noise and intensity noise of a continuous-wave laser

    Science.gov (United States)

    Michaud-Belleau, V.; Bergeron, H.; Light, P. S.; Hébert, N. B.; Deschênes, J. D.; Luiten, A. N.; Genest, J.

    2016-10-01

    The frequency noise and intensity noise of a laser set the performance limits in many modern photonics applications and, consequently, must often be characterized. As lasers continue to improve, the measurement of these noises however becomes increasingly challenging. Current approaches for the characterization of very high-performance lasers often call for a second laser with equal or higher performance to the one that is to be measured, an incoherent interferometer having an extremely long delay-arm, or an interferometer that relies on an active device. These instrumental features can be impractical or problematic under certain experimental conditions. As an alternative, this paper presents an entirely passive coherent interferometer that employs an optical 90° hybrid coupler to perform in-phase and quadrature detection. We demonstrate the technique by measuring the frequency noise power spectral density of a highly-stable 192 THz (1560 nm) fiber laser over five frequency decades. Simultaneously, we are able to measure its relative intensity noise power spectral density and characterize the correlation between its amplitude noise and phase noise. We correct some common misconceptions through a detailed theoretical analysis and demonstrate the necessity to account for normal imperfections of the optical 90° hybrid coupler. We finally conclude that this passive coherent discriminator is suitable for reliable and simple noise characterization of highly-stable lasers, with bandwidth and dynamic range benefits but susceptibility to additive noise contamination.

  11. High intensity interval and moderate continuous cycle training in a physical education programme improves health-related fitness in young females.

    Science.gov (United States)

    Mazurek, K; Zmijewski, P; Krawczyk, K; Czajkowska, A; Kęska, A; Kapuściński, P; Mazurek, T

    2016-06-01

    The aim of the study was to investigate the effects of eight weeks of regular physical education classes supplemented with high intensity interval cycle exercise (HIIE) or continuous cycle exercises of moderate intensity (CME). Forty-eight collegiate females exercising in two regular physical education classes per week were randomly assigned to two programmes (HIIE; n = 24 or CME; n = 24) of additional (one session of 63 minutes per week) physical activity for 8 weeks. Participants performed HIIE comprising 2 series of 6x10 s sprinting with maximal pedalling cadence and active recovery pedalling with intensity 65%-75% HRmax or performed CME corresponding to 65%-75% HRmax. Before and after the 8-week programmes, anthropometric data and aero- and anaerobic capacity were measured. Two-way ANOVA revealed a significant time main effect for VO2max (p body mass not changing significantly (p = 0.59; +0.4% in HIIE and -0.1% in CME). A significant main time effect was found for relative fat mass (FM) and fat-free mass (FFM) (p body composition than physical education classes supplemented with HIIE sessions. In contrast to earlier, smaller trials, similar improvements in aerobic capacity were observed following physical activity with additional HIIE or CME sessions.

  12. Correlation of neonatal intensive care unit performance across multiple measures of quality of care.

    Science.gov (United States)

    Profit, Jochen; Zupancic, John A F; Gould, Jeffrey B; Pietz, Kenneth; Kowalkowski, Marc A; Draper, David; Hysong, Sylvia J; Petersen, Laura A

    2013-01-01

    To examine whether high performance on one measure of quality is associated with high performance on others and to develop a data-driven explanatory model of neonatal intensive care unit (NICU) performance. We conducted a cross-sectional data analysis of a statewide perinatal care database. Risk-adjusted NICU ranks were computed for each of 8 measures of quality selected based on expert input. Correlations across measures were tested using the Pearson correlation coefficient. Exploratory factor analysis was used to determine whether underlying factors were driving the correlations. Twenty-two regional NICUs in California. In total, 5445 very low-birth-weight infants cared for between January 1, 2004, and December 31, 2007. Pneumothorax, growth velocity, health care-associated infection, antenatal corticosteroid use, hypothermia during the first hour of life, chronic lung disease, mortality in the NICU, and discharge on any human breast milk. The NICUs varied substantially in their clinical performance across measures of quality. Of 28 unit-level correlations, 6 were significant (ρ < .05). Correlations between pairs of measures of quality of care were strong (ρ ≥ .5) for 1 pair, moderate (range, ρ ≥ .3 to ρ < .5) for 8 pairs, weak (range, ρ ≥ .1 to ρ < .3) for 5 pairs, and negligible (ρ < .1) for 14 pairs. Exploratory factor analysis revealed 4 underlying factors of quality in this sample. Pneumothorax, mortality in the NICU, and antenatal corticosteroid use loaded on factor 1; growth velocity and health care-associated infection loaded on factor 2; chronic lung disease loaded on factor 3; and discharge on any human breast milk loaded on factor 4. In this sample, the ability of individual measures of quality to explain overall quality of neonatal intensive care was modest.

  13. Vocal intensity in lecturers: Results of measurements conducted during lecture sessions

    Directory of Open Access Journals (Sweden)

    Witold Mikulski

    2013-12-01

    Full Text Available Background: Occupational voice users (inter alia: lecturers speak with different levels of vocal intensity. Speakers adjust this intensity knowingly (e.g. to underline the importance of fragments of the speech or unknowingly. The unknown adjustment of voice intensity occurs e.g. in the presence of high acoustic background noise (so-called Lombard effect, but it also results from many other factors: hearing loss, construction of the vocal tract, habits and others. The aim of the article is to confirm the thesis that in similar conditions of acoustic properties of the room different lecturers speak with different levels of vocal intensity. Materials and Methods: The study was conducted in a group of 10 lecturers in the same conference room. A-weighted sound pressure level determined at 1 m from the lecturer's mouth was adopted as a parameter defining the intensity of the lecturer's voice. The levels of all lecturers' voice intensity were compared and evaluated according to the criteria defined in EN ISO 9921. Results: Nine in ten lecturers were speaking with normal voice intensity (60-65 dB and only one full-time university lecturer was speaking with raised voice (66-71 dB. Conclusions: It was found that in the room of the same acoustic conditions the lecturers spoke with different intensities of voice. Some lecturers occasionally, and one all the time spoke with the voice intensity specified by PN-EN ISO 9921 as a raised voice. The results of the preliminary study warrant further studies in a larger group of teachers. Med Pr 2013;64(6:797–804

  14. The processing of infrequently-presented low-intensity stimuli during natural sleep: An event-related potential study

    Directory of Open Access Journals (Sweden)

    Alexandra Muller-Gass

    2010-01-01

    Full Text Available Event-related potentials (ERPs provide an exquisite means to measure the extent of processing of external stimuli during the sleep period. This study examines ERPs elicited by stimuli with physical characteristics akin to environmental noise encountered during sleep. Brief duration 40, 60 or 80 dB sound pressure level (SPL tones were presented either rapidly (on average every two seconds or slowly (on average every 10 seconds. The rates of presentation and intensity of the stimuli were similar to those observed in environmental studies of noise. ERPs were recorded from nine young adults during sleep and wakefulness. During wakefulness, the amplitude of an early negative ERP, N1, systematically increased as intensity level increased. A later positivity, the P3a, was apparent following the loudest 80 dB stimulus regardless of the rate of stimulus presentation; it was also apparent following the 60 dB stimulus, when stimuli were presented slowly. The appearance of the N1-P3a deflections suggests that operations of the central executive controlling ongoing cognitive activity was interrupted, forcing subjects to become aware of the obtrusive task-irrelevant stimuli. The auditory stimuli elicited very different ERP patterns during sleep. During non-rapid eye movement (NREM sleep, the ERP was characterized by an enhanced (relative to wakefulness early positivity, P2, followed by a very prominent negativity, the N350. Both deflections systematically varied in amplitude with stimulus intensity level; in addition, N350 was much larger when stimuli were presented at slow rates. The N350, a sleep-specific ERP, is thought to reflect the inhibition of processing of potentially sleep-disrupting stimulus input. During rapid eye movement (REM sleep, a small amplitude N1 was apparent in the ERP, but only for the loudest, 80 dB stimulus. A small (nonsignificant P3a-like deflection was also visible following the 80 dB stimulus, but only when stimuli were presented

  15. Age-Related Changes in Associations Between Reasons for Alcohol Use and High-Intensity Drinking Across Young Adulthood.

    Science.gov (United States)

    Patrick, Megan E; Evans-Polce, Rebecca; Kloska, Deborah D; Maggs, Jennifer L; Lanza, Stephanie T

    2017-07-01

    Analyses focus on whether self-reported reasons for drinking alcohol change in their associations with high-intensity drinking across the transition to adulthood. Self-report data on high-intensity drinking (10+ drinks) collected from the national Monitoring the Future study in 2005 to 2014 from those ages 18-26 were used (N = 2,664 [60% women] for all drinkers and 1,377 for heavy episodic [5+] drinkers; up to 6,541 person-waves). Time-varying effect modeling examined changes in the direction and magnitude of associations between eight reasons for drinking and high-intensity alcohol use across continuous age. Four reasons to drink showed quite stable associations with high-intensity drinking across age: drinking to get away from problems, to get high, to relax, and to sleep. Associations between two reasons and high-intensity drinking decreased with age: anger/frustration and to have a good time. The association between drinking because of boredom and high-intensity drinking increased with age. Drinking because it tastes good had a weak association with high-intensity drinking. Among heavy episodic drinkers, reasons for use also differentiated high-intensity drinking, with two exceptions: drinking to have a good time and to relax did not distinguish drinking 10+ drinks from drinking 5-9 drinks. Reasons for drinking are differentially associated with high-intensity drinking, compared with any other drinking and compared with lower intensity heavy drinking, across age during the transition to adulthood. Intervention programs seeking to mitigate alcohol-related harms should focus on reasons for use when they are the most developmentally salient.

  16. Intensity ratio to improve black hole assessment in multiple sclerosis.

    Science.gov (United States)

    Adusumilli, Gautam; Trinkaus, Kathryn; Sun, Peng; Lancia, Samantha; Viox, Jeffrey D; Wen, Jie; Naismith, Robert T; Cross, Anne H

    2018-01-01

    Improved imaging methods are critical to assess neurodegeneration and remyelination in multiple sclerosis. Chronic hypointensities observed on T1-weighted brain MRI, "persistent black holes," reflect severe focal tissue damage. Present measures consist of determining persistent black holes numbers and volumes, but do not quantitate severity of individual lesions. Develop a method to differentiate black and gray holes and estimate the severity of individual multiple sclerosis lesions using standard magnetic resonance imaging. 38 multiple sclerosis patients contributed images. Intensities of lesions on T1-weighted scans were assessed relative to cerebrospinal fluid intensity using commercial software. Magnetization transfer imaging, diffusion tensor imaging and clinical testing were performed to assess associations with T1w intensity-based measures. Intensity-based assessments of T1w hypointensities were reproducible and achieved > 90% concordance with expert rater determinations of "black" and "gray" holes. Intensity ratio values correlated with magnetization transfer ratios (R = 0.473) and diffusion tensor imaging metrics (R values ranging from 0.283 to -0.531) that have been associated with demyelination and axon loss. Intensity ratio values incorporated into T1w hypointensity volumes correlated with clinical measures of cognition. This method of determining the degree of hypointensity within multiple sclerosis lesions can add information to conventional imaging. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. High-intensity interval training for improving health-related fitness in adolescents: a systematic review and meta-analysis.

    Science.gov (United States)

    Costigan, S A; Eather, N; Plotnikoff, R C; Taaffe, D R; Lubans, D R

    2015-10-01

    High-intensity interval training (HIIT) may be a feasible and efficacious strategy for improving health-related fitness in young people. The objective of this systematic review and meta-analysis was to evaluate the utility of HIIT to improve health-related fitness in adolescents and to identify potential moderators of training effects. Studies were considered eligible if they: (1) examined adolescents (13-18 years); (2) examined health-related fitness outcomes; (3) involved an intervention of ≥4 weeks in duration; (4) included a control or moderate intensity comparison group; and (5) prescribed high-intensity activity for the HIIT condition. Meta-analyses were conducted to determine the effect of HIIT on health-related fitness components using Comprehensive Meta-analysis software and potential moderators were explored (ie, study duration, risk of bias and type of comparison group). The effects of HIIT on cardiorespiratory fitness and body composition were large, and medium, respectively. Study duration was a moderator for the effect of HIIT on body fat percentage. Intervention effects for waist circumference and muscular fitness were not statistically significant. HIIT is a feasible and time-efficient approach for improving cardiorespiratory fitness and body composition in adolescent populations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Accurate line intensities of methane from first-principles calculations

    Science.gov (United States)

    Nikitin, Andrei V.; Rey, Michael; Tyuterev, Vladimir G.

    2017-10-01

    In this work, we report first-principle theoretical predictions of methane spectral line intensities that are competitive with (and complementary to) the best laboratory measurements. A detailed comparison with the most accurate data shows that discrepancies in integrated polyad intensities are in the range of 0.4%-2.3%. This corresponds to estimations of the best available accuracy in laboratory Fourier Transform spectra measurements for this quantity. For relatively isolated strong lines the individual intensity deviations are in the same range. A comparison with the most precise laser measurements of the multiplet intensities in the 2ν3 band gives an agreement within the experimental error margins (about 1%). This is achieved for the first time for five-atomic molecules. In the Supplementary Material we provide the lists of theoretical intensities at 269 K for over 5000 strongest transitions in the range below 6166 cm-1. The advantage of the described method is that this offers a possibility to generate fully assigned exhaustive line lists at various temperature conditions. Extensive calculations up to 12,000 cm-1 including high-T predictions will be made freely available through the TheoReTS information system (http://theorets.univ-reims.fr, http://theorets.tsu.ru) that contains ab initio born line lists and provides a user-friendly graphical interface for a fast simulation of the absorption cross-sections and radiance.

  19. Objectively measured sedentary time may predict insulin resistance independent of moderate- and vigorous-intensity physical activity

    NARCIS (Netherlands)

    Helmerhorst, Hendrik J. F.; Wijndaele, Katrien; Brage, Søren; Wareham, Nicholas J.; Ekelund, Ulf

    2009-01-01

    To examine the prospective association between objectively measured time spent sedentary and insulin resistance and whether this association is independent of moderate- and vigorous-intensity physical activity (MVPA) and other relevant confounders. This was a population-based study (Medical Research

  20. Desensitizing addiction: using eye movements to reduce the intensity of substance-related mental imagery and craving

    Directory of Open Access Journals (Sweden)

    Marianne eLittel

    2016-02-01

    Full Text Available Eye movement desensitization and reprocessing (EMDR is an effective treatment for posttraumatic stress disorder. During this treatment, patients recall a traumatic memory while making horizontal eye movements (EM. Studies have shown that EM not only desensitize negative memories, but also positive memories and imagined events. Substance use behavior and craving are maintained by maladaptive memory associations and visual imagery. Preliminary findings have indicated that these mental images can be desensitized by EMDR techniques. We conducted two proof-of-principle studies to investigate whether EM can reduce the sensory richness of substance-related mental representations and accompanying craving levels. We investigated the effects of EM on 1 vividness of food-related mental imagery and food craving in dieting and non-dieting students, and 2 vividness of recent smoking-related memories and cigarette craving in daily smokers. In both experiments, participants recalled the images while making EM or keeping eyes stationary. Image vividness and emotionality, image-specific craving and general craving were measured before and after the intervention. As a behavioral outcome measure, participants in study 1 were offered a snack choice at the end of the experiment.Results of both experiments showed that image vividness and craving increased in the control condition, but remained stable or decreased after the EM intervention. EM additionally reduced image emotionality (exp 2, and affected behavior (exp 1: participants in the EM condition were more inclined to choose healthy over unhealthy snack options. In conclusion, the data suggest that EM can be used to reduce intensity of substance related imagery and craving. Although long-term effects are yet to be demonstrated, the current studies suggest that EM might be a useful technique in addiction treatment.

  1. Transfer standard for the spectral density of relative intensity noise of optical fiber sources near 1550 nm

    Energy Technology Data Exchange (ETDEWEB)

    Obarski, Gregory E.; Splett, Jolene D.

    2001-06-01

    We have developed a transfer standard for the spectral density of relative intensity noise (RIN) of optical fiber sources near 1550 nm. Amplified spontaneous emission (ASE) from an erbium-doped fiber amplifier (EDFA), when it is optically filtered over a narrow band ({lt}5 nm), yields a stable RIN spectrum that is practically constant to several tens of gigahertz. The RIN is calculated from the power spectral density as measured with a calibrated optical spectrum analyzer. For a typical device it is {minus}110 dB/Hz, with uncertainty {le}0.12 dB/Hz. The invariance of the RIN under attenuation yields a considerable dynamic range with respect to rf noise levels. Results are compared with those from a second method that uses a distributed-feedback laser (DFB) that has a Poisson-limited RIN. Application of each method to the same RIN measurement system yields frequency-dependent calibration functions that, when they are averaged, differ by {le}0.2 dB. {copyright} 2001 Optical Society of America

  2. Relative ultrasound energy measurement circuit

    OpenAIRE

    Gustafsson, E.Martin I.; Johansson, Jonny; Delsing, Jerker

    2005-01-01

    A relative ultrasound energy estimation circuit has been designed in a standard 0.35-μm CMOS process, to be a part of a thumb size internet connected wireless ultrasound measurement system. This circuit measures the relative energy between received ultrasound pulses, and presents an output signal that is linear to the received energy. Post-layout simulations indicate 7 bit linearity for 500 mV input signals, 5 μsec startup and stop times, 2.6 mW power consumption during active state. The acti...

  3. Cerebral oxygenation as measured by near-infrared spectroscopy in neonatal intensive care: correlation with arterial oxygenation.

    Science.gov (United States)

    Hunter, Carol Lu; Oei, Ju Lee; Lui, Kei; Schindler, Timothy

    2017-07-01

    To assess correlation between cerebral oxygenation (rScO 2 ), as measured by near-infrared spectroscopy (NIRS), and arterial oxygenation (PaO 2 ), as measured by arterial blood gases, in preterm neonates. Preterm neonates interpretation of NIRS values in neonatal intensive care, and further evaluation is needed to determine the applicability of NIRS to management of preterm infants. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  4. Measurement of intense coherent synchrotron radiation at frequencies around 0.1 THz using the compact S-band linac

    International Nuclear Information System (INIS)

    Sei, Norihiro; Kuroda, Ryunosuke; Yasumoto, Masato; Toyokawa, Hiroyuki; Ogawa, Hiroshi; Koike, Masaki; Yamada, Kawakatsu

    2008-01-01

    We measured intense radiation from an electron bunch in a millimeter wave region using the compact S-band linac. The dependence of the radiation on the electron-bunch charge was measured with an rf detector system at frequencies around 0.1 THz and was confirmed to be a coherent synchrotron radiation (CSR). The total power of the horizontally and vertically polarized CSRs, which were extracted through the Z-cut quartz window within 1 ns, was calculated to be about 88 and 30 nJ/pulse, excluding the absorption by the window. The two-dimensional distribution of the vertically polarized CSR was measured at a distance of about 0.7 m from the radiation point. The CSR distribution was comparatively uniform in the horizontal plane. Intense CSR, which was reflected in the vacuum chamber, was extracted with a delay of about 6 ns. This suggests that measurement of temporal structure is needed for CSR applications

  5. The communication between patient relatives and physicians in intensive care units.

    Science.gov (United States)

    Cicekci, Faruk; Duran, Numan; Ayhan, Bunyamin; Arican, Sule; Ilban, Omur; Kara, Iskender; Turkoglu, Melda; Yildirim, Fatma; Hasirci, Ismail; Karaibrahimoglu, Adnan; Kara, Inci

    2017-07-17

    Patients in intensive care units (ICUs) are often physically unable to communicate with their physicians. Thus, the sharing of information about the on-going treatment of the patients in ICUs is directly related to the communication attitudes governing a patient's relatives and the physician. This study aims to analyze the attitudes displayed by the relatives of patients and the physician with the purpose of determining the communication between the two parties. For data collection, two similar survey forms were created in context of the study; one for the relatives of the patients and one for the ICU physicians. The questionnaire included three sub-dimensions: informing, empathy and trust. The study included 181 patient relatives and 103 ICU physicians from three different cities and six hospitals. Based on the results of the questionnaire, identification of the mutual expectations and substance of the messages involved in the communication process between the ICU patients' relatives and physicians was made. The gender and various disciplines of the physicians and the time of the conversation with the patients' relatives were found to affect the communication attitude towards the patient. Moreover, the age of the patient's relatives, the level of education, the physician's perception, and the contact frequency with the patient when he/she was healthy were also proven to have an impact on the communication attitude of the physician. This study demonstrates the mutual expectations and substance of messages in the informing, empathy and trust sub-dimensions of the communication process between patient relatives and physicians in the ICU. The communication between patient relatives and physicians can be strengthened through a variety of training programs to improve communication skills.

  6. Reliability of reagent strips for semi-quantitative measurement of glucosuria in a neonatal intensive care setting

    NARCIS (Netherlands)

    Bekhof, Jolita; Kollen, Boudewijn J.; van de Leur, Sjef; Kok, Joke H.; van Straaten, Irma H. L. M.

    2014-01-01

    Glucosuria in preterm infants is often measured using a visually readable reagent strip, e.g., when monitoring total parenteral nutrition or during sepsis or when treating with corticosteroids. However, the specific circumstances in a neonatal intensive care unit (NICU), such as the use of diapers

  7. Reliability of Reagent Strips for Semi-quantitative Measurement of Glucosuria in a Neonatal Intensive Care Setting

    NARCIS (Netherlands)

    Bekhof, Jolita; Kollen, Boudewijn J.; van de Leur, Sjef; Kok, Joke H.; van Straaten, Irma H. L. M.

    2014-01-01

    Background: Glucosuria in preterm infants is often measured using a visually readable reagent strip, e.g., when monitoring total parenteral nutrition or during sepsis or when treating with corticosteroids. However, the specific circumstances in a neonatal intensive care unit (NICU), such as the use

  8. Avidity of anti-malarial antibodies inversely related to transmission intensity at three sites in Uganda.

    Science.gov (United States)

    Ssewanyana, Isaac; Arinaitwe, Emmanuel; Nankabirwa, Joaniter I; Yeka, Adoke; Sullivan, Richard; Kamya, Moses R; Rosenthal, Philip J; Dorsey, Grant; Mayanja-Kizza, Harriet; Drakeley, Chris; Greenhouse, Bryan; Tetteh, Kevin K A

    2017-02-10

    People living in malaria endemic areas acquire protection from severe malaria quickly, but protection from clinical disease and control of parasitaemia is acquired only after many years of repeated infections. Antibodies play a central role in protection from clinical disease; however, protective antibodies are slow to develop. This study sought to investigate the influence of Plasmodium falciparum exposure on the acquisition of high-avidity antibodies to P. falciparum antigens, which may be associated with protection. Cross-sectional surveys were performed in children and adults at three sites in Uganda with varied P. falciparum transmission intensity (entomological inoculation rates; 3.8, 26.6, and 125 infectious bites per person per year). Sandwich ELISA was used to measure antibody responses to two P. falciparum merozoite surface antigens: merozoite surface protein 1-19 (MSP1-19) and apical membrane antigen 1 (AMA1). In individuals with detectable antibody levels, guanidine hydrochloride (GuHCl) was added to measure the relative avidity of antibody responses by ELISA. Within a site, there were no significant differences in median antibody levels between the three age groups. Between sites, median antibody levels were generally higher in the higher transmission sites, with differences more apparent for AMA-1 and in ≥5 year group. Similarly, median avidity index (proportion of high avidity antibodies) showed no significant increase with increasing age but was significantly lower at sites of higher transmission amongst participants ≥5 years of age. Using 5 M GuHCl, the median avidity indices in the ≥5 year group at the highest and lowest transmission sites were 19.9 and 26.8, respectively (p = 0.0002) for MSP1-19 and 12.2 and 17.2 (p = 0.0007) for AMA1. Avidity to two different P. falciparum antigens was lower in areas of high transmission intensity compared to areas with lower transmission. Appreciation of the mechanisms behind these findings as

  9. The Role of Parental Perceptions of Tic Frequency and Intensity in Predicting Tic-Related Functional Impairment in Youth with Chronic Tic Disorders

    Science.gov (United States)

    Espil, Flint M.; Capriotti, Matthew R.; Conelea, Christine A.; Woods, Douglas W.

    2014-01-01

    Tic severity is composed of several dimensions. Tic frequency and intensity are two such dimensions, but little empirical data exist regarding their relative contributions to functional impairment in those with Chronic Tic Disorders (CTD). The present study examined the relative contributions of these dimensions in predicting tic-related impairment across several psychosocial domains. Using data collected from parents of youth with CTD, multivariate regression analyses revealed that both tic frequency and intensity predicted tic-related impairment in several areas; including family and peer relationships, school interference, and social endeavors, even when controlling for the presence of comorbid anxiety symptoms and Attention Deficit Hyperactivity Disorder diagnostic status. Results showed that tic intensity predicted more variance across more domains than tic frequency. PMID:24395287

  10. The role of parental perceptions of tic frequency and intensity in predicting tic-related functional impairment in youth with chronic tic disorders.

    Science.gov (United States)

    Espil, Flint M; Capriotti, Matthew R; Conelea, Christine A; Woods, Douglas W

    2014-12-01

    Tic severity is composed of several dimensions. Tic frequency and intensity are two such dimensions, but little empirical data exist regarding their relative contributions to functional impairment in those with chronic tic disorders (CTD). The present study examined the relative contributions of these dimensions in predicting tic-related impairment across several psychosocial domains. Using data collected from parents of youth with CTD, multivariate regression analyses revealed that both tic frequency and intensity predicted tic-related impairment in several areas; including family and peer relationships, school interference, and social endeavors, even when controlling for the presence of comorbid anxiety symptoms and Attention Deficit Hyperactivity Disorder diagnostic status. Results showed that tic intensity predicted more variance across more domains than tic frequency.

  11. Review of intense-ion-beam propagation with a view toward measuring ion energy

    International Nuclear Information System (INIS)

    Garcia, M.

    1982-01-01

    The subject of this review is intense ion beam propagation and the possibilities of measuring time dependent ion energy in the beam. Propagation effects discussed include charge separation, charge and current autoneutralization, electron thermalization and current neutralization decay. The interaction of a plasma beam with material obstacles, like collimators, and with transverse magnetic fields is also described. Depending on beam energy, density and pulse length, these interactions can include material ablation with plasmadynamic flow and undeflected propagation across transverse magnetic fields by a polarization drift. On the basis of this review I conclude that three diagnostics: a single floating potential probe, net current probes (Faraday cups) and a Rutherford scattering spectrometer appear capable of giving prompt, time dependent ion energy measurements

  12. Adding high-intensity interval training to conventional training modalities: optimizing health-related outcomes during chemotherapy for breast cancer: the OptiTrain randomized controlled trial.

    Science.gov (United States)

    Mijwel, Sara; Backman, Malin; Bolam, Kate A; Jervaeus, Anna; Sundberg, Carl Johan; Margolin, Sara; Browall, Maria; Rundqvist, Helene; Wengström, Yvonne

    2018-02-01

    Exercise training is an effective and safe way to counteract cancer-related fatigue (CRF) and to improve health-related quality of life (HRQoL). High-intensity interval training has proven beneficial for the health of clinical populations. The aim of this randomized controlled trial was to compare the effects of resistance and high-intensity interval training (RT-HIIT), and moderate-intensity aerobic and high-intensity interval training (AT-HIIT) to usual care (UC) in women with breast cancer undergoing chemotherapy. The primary endpoint was CRF and the secondary endpoints were HRQoL and cancer treatment-related symptoms. Two hundred and forty women planned to undergo chemotherapy were randomized to supervised RT-HIIT, AT-HIIT, or UC. Measurements were performed at baseline and at 16 weeks. Questionnaires included Piper Fatigue Scale, EORTC-QLQ-C30, and Memorial Symptom Assessment Scale. The RT-HIIT group was superior to UC for CRF: total CRF (p = 0.02), behavior/daily life (p = 0.01), and sensory/physical (p = 0.03) CRF. Role functioning significantly improved while cognitive functioning was unchanged for RT-HIIT compared to declines shown in the UC group (p = 0.04). AT-HIIT significantly improved emotional functioning versus UC (p = 0.01) and was superior to UC for pain symptoms (p = 0.03). RT-HIIT reported a reduced symptom burden, while AT-HIIT remained stable compared to deteriorations shown by UC (p HIIT was superior to UC for total symptoms (p HIIT was effective in preventing increases in CRF and in reducing symptom burden for patients during chemotherapy for breast cancer. These findings add to a growing body of evidence supporting the inclusion of structured exercise prescriptions, including HIIT, as a vital component of cancer rehabilitation. Clinicaltrials.gov Registration Number: NCT02522260.

  13. Modeling of energy consumption and related GHG (greenhouse gas) intensity and emissions in Europe using general regression neural networks

    International Nuclear Information System (INIS)

    Antanasijević, Davor; Pocajt, Viktor; Ristić, Mirjana; Perić-Grujić, Aleksandra

    2015-01-01

    This paper presents a new approach for the estimation of energy-related GHG (greenhouse gas) emissions at the national level that combines the simplicity of the concept of GHG intensity and the generalization capabilities of ANNs (artificial neural networks). The main objectives of this work includes the determination of the accuracy of a GRNN (general regression neural network) model applied for the prediction of EC (energy consumption) and GHG intensity of energy consumption, utilizing general country statistics as inputs, as well as analysis of the accuracy of energy-related GHG emissions obtained by multiplying the two aforementioned outputs. The models were developed using historical data from the period 2004–2012, for a set of 26 European countries (EU Members). The obtained results demonstrate that the GRNN GHG intensity model provides a more accurate prediction, with the MAPE (mean absolute percentage error) of 4.5%, than tested MLR (multiple linear regression) and second-order and third-order non-linear MPR (multiple polynomial regression) models. Also, the GRNN EC model has high accuracy (MAPE = 3.6%), and therefore both GRNN models and the proposed approach can be considered as suitable for the calculation of GHG emissions. The energy-related predicted GHG emissions were very similar to the actual GHG emissions of EU Members (MAPE = 6.4%). - Highlights: • ANN modeling of GHG intensity of energy consumption is presented. • ANN modeling of energy consumption at the national level is presented. • GHG intensity concept was used for the estimation of energy-related GHG emissions. • The ANN models provide better results in comparison with conventional models. • Forecast of GHG emissions for 26 countries was made successfully with MAPE of 6.4%

  14. Catheter-related infection in Irish intensive care units diagnosed with HELICS criteria: a multi-centre surveillance study.

    LENUS (Irish Health Repository)

    Conrick-Martin, I

    2013-03-01

    Catheter-related infection (CRI) surveillance is advocated as a healthcare quality indicator. However, there is no national CRI surveillance programme or standardized CRI definitions in Irish intensive care units (ICUs).

  15. SALIVARY CORTISOL RESPONSES AND PERCEIVED EXERTION DURING HIGH INTENSITY AND LOW INTENSITY BOUTS OF RESISTANCE EXERCISE

    Directory of Open Access Journals (Sweden)

    Alison D. Egan

    2004-03-01

    Full Text Available The purpose of this study was to measure the salivary cortisol response to different intensities of resistance exercise. In addition, we wanted to determine the reliability of the session rating of perceived exertion (RPE scale to monitor resistance exercise intensity. Subjects (8 men, 9 women completed 2 trials of acute resistance training bouts in a counterbalanced design. The high intensity resistance exercise protocol consisted of six, ten-repetition sets using 75% of one repetition maximum (RM on a Smith machine squat and bench press exercise (12 sets total. The low intensity resistance exercise protocol consisted of three, ten-repetition sets at 30% of 1RM of the same exercises as the high intensity protocol. Both exercise bouts were performed with 2 minutes of rest between each exercise and sessions were repeated to test reliability of the measures. The order of the exercise bouts was randomized with least 72 hours between each session. Saliva samples were obtained immediately before, immediately after and 30 mins following each resistance exercise bout. RPE measures were obtained using Borg's CR-10 scale following each set. Also, the session RPE for the entire exercise session was obtained 30 minutes following completion of the session. There was a significant 97% increase in the level of salivary cortisol immediately following the high intensity exercise session (P<0.05. There was also a significant difference in salivary cortisol of 145% between the low intensity and high intensity exercise session immediately post-exercise (P<0.05. The low intensity exercise did not result in any significant changes in cortisol levels. There was also a significant difference between the session RPE values for the different intensity levels (high intensity 7.1 vs. low intensity 1.9 (P<0.05. The intraclass correlation coefficient for the session RPE measure was 0.95. It was concluded that the session RPE method is a valid and reliable method of

  16. Life satisfaction in patients with chronic pain – relation to pain intensity, disability, and psychological factors

    Directory of Open Access Journals (Sweden)

    Stålnacke BM

    2011-11-01

    Full Text Available Britt-Marie StålnackeDepartment of Community Medicine and Rehabilitation, Umeå University, Umeå, SwedenAims: To investigate pain intensity, posttraumatic stress, depression, anxiety, disability, and life satisfaction in patients with injury-related chronic pain and to analyze differences in these variables regarding gender.Methods: Questionnaires addressing pain intensity (visual analogue scale [VAS], anxiety and depression (hospital anxiety and depression [HAD] scale, posttraumatic stress (impact of event scale, disability (disability rating index, and life satisfaction [LiSat-11] were answered by 160 patients at assessment at the Pain Rehabilitation Clinic at the Umeå University Hospital (Umeå, Sweden.Results: High level of pain intensity was scored on the VAS (mean value 64.5 ± 21.1 mm together with high levels of anxiety, depression, and posttraumatic stress. Activity limitations in everyday life and decreased life satisfaction were reported, especially on the items physical health and psychological health. A multivariate logistic regression model showed a statistically significant association between low scores on the overall life satisfaction on LiSat-11 and high scores on HAD-depression (odds ratio = 1.141, confidence interval 1.014–1.285. Few gender differences were found.Conclusion: These findings highlight the value of a broad screening in patients with injury-related chronic pain with respect to the relationship of life satisfaction with pain intensity, anxiety, depression, posttraumatic stress, and disability. In addition, these findings support the biopsychosocial approach to assess and treat these patients optimally.Keywords: whiplash injuries, depression, quality of life

  17. Definition of dose intensity (DI), average relative DI and effective DI

    International Nuclear Information System (INIS)

    Alberto, P.

    1995-01-01

    The cytotoxic activity of cancer chemotherapy is related to the dose and to the amount of drug delivered per time unit. the significance of time in the effectiveness of a treatment program is frequently overlooked. The term of dose intensity (DI) is used to define the drug dose delivered per time unit and is expressed as mg/m 2 per week. A delay in the sequence of treatment cycles decreases the DI in the DI in the same proportion as a reduction of dose. Average relative DI corresponds to the mean DI of combined agents and is expressed as a fraction of a similar combination selected as a standard. Di is useful to compare the dose actually received with the prescribed dose. The relation of DI with tumor response or survival has not been fully demonstrated. A threshold DI level for therapeutic activity is evident. Above this threshold, a linear relationship of DI and effectiveness is not obvious, particularly regarding high-dose chemotherapy. The term of DI is more useful in its principle than in the significance of its calculated value. (authors). 19 refs., 3 tabs., 3 figs

  18. Optimal ground motion intensity measure for long-period structures

    International Nuclear Information System (INIS)

    Guan, Minsheng; Du, Hongbiao; Zeng, Qingli; Cui, Jie; Jiang, Haibo

    2015-01-01

    This paper aims to select the most appropriate ground motion intensity measure (IM) that is used in selecting earthquake records for the dynamic time history analysis of long-period structures. For this purpose, six reinforced concrete frame-core wall structures, designed according to modern seismic codes, are studied through dynamic time history analyses with a set of twelve selected earthquake records. Twelve IMs and two types of seismic damage indices, namely, the maximum seismic response-based and energy-based parameters, are chosen as the examined indices. Selection criteria such as correlation, efficiency, and proficiency are considered in the selection process. The optimal IM is identified by means of a comprehensive evaluation using a large number of data of correlation, efficiency, and proficiency coefficients. Numerical results illustrate that peak ground velocity is the optimal one for long-period structures and peak ground displacement is also a close contender. As compared to previous reports, the spectral-correlated parameters can only be taken as moderate IMs. Moreover, the widely used peak ground acceleration in the current seismic codes is considered inappropriate for long-period structures. (paper)

  19. Progress toward a microsecond duration, repetitive, intense-ion beam for active spectroscopic measurements on ITER

    International Nuclear Information System (INIS)

    Davis, H.A.; Bartsch, R.R.; Barnes, C.W.

    1996-01-01

    The authors describe the design of an intense, pulsed, repetitive, neutral beam based on magnetically insulated diode technology for injection into ITER for spectroscopic measurements of thermalizing alpha particle and thermal helium density profiles, ion temperature, plasma rotation, and low Z impurity concentrations in the confinement region. The beam is being developed to enhance low signal-to-noise ratios expected with conventional steady-state ion beams because of severe beam attenuation and intense bremstrahlung emission. A 5 GW (e.g., 100 keV, 50 kA) one-microsecond-duration beam would increase the signal by 10 3 compared to a conventional 5 MW beam with signal-to-noise ratios comparable to those from a chopped conventional beam in one second

  20. Real-time monitoring of longitudinal electron bunch parameters by intensity-integrated and spectroscopic measurements of single coherent THz pulses

    International Nuclear Information System (INIS)

    Wesch, Stephan

    2012-12-01

    High-gain free-electron lasers (FELs) generate intense and monochromatic photon pulses with few tens of femtosecond duration. For this purpose, electron beams are accelerated to relativistic energies and shrunk longitudinally down to micrometer size.The diagnosis of theses compressed electron bunches is a challenge especially for MHz bunch repetition rates as provided by the FEL FLASH in Hamburg. In this thesis, coherently emitted THz radiation of single electron bunches were investigated, on which the longitudinal structure is imprinted. Two instruments were used: First, the FLASH bunch compression monitors, relying on the integrated intensity measurement of diffraction radiation, were modified to determine the overall length of every bunch behind the two bunch compressors (BC). A model was developed showing that their response is independent of the exact bunch shape for lengths below 200 μm (rms). This could experimentally be verified in the range between 50 and 190 μm within 7% accuracy for themonitor behind the last BC by comparison with measurements with the transverse deflecting structure (TDS). Second, a single-shot spectrometer with five staged reflective blazed gratings has been designed, build and commissioned. With its two grating sets, the wavelength ranges from 5.5 to 44 μm and 45 to 440 μm can be simultaneously detected by 118 fast pyroelectric elements. Measurements based on transition radiation spectra were compared with profiles recorded by the TDS.The shape of the spectra as well as the reconstructed temporal profiles (using the Kramers-Kronig relation for phase retrieval) are in excellent agreement. For bunches with a charge of 50 pC, bunch lengths down to 5 μm (fhwm) could be detected.

  1. Measurement of Rapid Protein Diffusion in the Cytoplasm by Photo-Converted Intensity Profile Expansion

    Directory of Open Access Journals (Sweden)

    Rotem Gura Sadovsky

    2017-03-01

    Full Text Available The fluorescence microscopy methods presently used to characterize protein motion in cells infer protein motion from indirect observables, rather than measuring protein motion directly. Operationalizing these methods requires expertise that can constitute a barrier to their broad utilization. Here, we have developed PIPE (photo-converted intensity profile expansion to directly measure the motion of tagged proteins and quantify it using an effective diffusion coefficient. PIPE works by pulsing photo-convertible fluorescent proteins, generating a peaked fluorescence signal at the pulsed region, and analyzing the spatial expansion of the signal. We demonstrate PIPE’s success in measuring accurate diffusion coefficients in silico and in vitro and compare effective diffusion coefficients of native cellular proteins and free fluorophores in vivo. We apply PIPE to measure diffusion anomality in the cell and use it to distinguish free fluorophores from native cellular proteins. PIPE’s direct measurement and ease of use make it appealing for cell biologists.

  2. Simple method based on intensity measurements for characterization of aberrations from micro-optical components.

    Science.gov (United States)

    Perrin, Stephane; Baranski, Maciej; Froehly, Luc; Albero, Jorge; Passilly, Nicolas; Gorecki, Christophe

    2015-11-01

    We report a simple method, based on intensity measurements, for the characterization of the wavefront and aberrations produced by micro-optical focusing elements. This method employs the setup presented earlier in [Opt. Express 22, 13202 (2014)] for measurements of the 3D point spread function, on which a basic phase-retrieval algorithm is applied. This combination allows for retrieval of the wavefront generated by the micro-optical element and, in addition, quantification of the optical aberrations through the wavefront decomposition with Zernike polynomials. The optical setup requires only an in-motion imaging system. The technique, adapted for the optimization of micro-optical component fabrication, is demonstrated by characterizing a planoconvex microlens.

  3. Prospects for UT1 Measurements from VLBI Intensive Sessions

    Science.gov (United States)

    Boehm, Johannes; Nilsson, Tobias; Schuh, Harald

    2010-01-01

    Very Long Baseline Interferometry (VLBI) Intensives are one-hour single baseline sessions to provide Universal Time (UT1) in near real-time up to a delay of three days if a site is not e-transferring the observational data. Due to the importance of UT1 estimates for the prediction of Earth orientation parameters, as well as any kind of navigation on Earth or in space, there is not only the need to improve the timeliness of the results but also their accuracy. We identify the asymmetry of the tropospheric delays as the major error source, and we provide two strategies to improve the results, in particular of those Intensives which include the station Tsukuba in Japan with its large tropospheric variation. We find an improvement when (1) using ray-traced delays from a numerical weather model, and (2) when estimating tropospheric gradients within the analysis of Intensive sessions. The improvement is shown in terms of reduction of rms of length-of-day estimates w.r.t. those derived from Global Positioning System observations

  4. Measurement of {sup 1}H-{sup 15}N and {sup 1}H-{sup 13}C residual dipolar couplings in nucleic acids from TROSY intensities

    Energy Technology Data Exchange (ETDEWEB)

    Ying Jinfa [National Institutes of Health, Laboratory of Chemical Physics, National Institute of Diabetes and Digestive and Kidney Diseases (United States); Wang Jinbu [National Cancer Institute, National Institutes of Health, Structural Biophysics Laboratory (United States); Grishaev, Alex [National Institutes of Health, Laboratory of Chemical Physics, National Institute of Diabetes and Digestive and Kidney Diseases (United States); Yu Ping; Wang Yunxing [National Cancer Institute, National Institutes of Health, Structural Biophysics Laboratory (United States); Bax, Ad, E-mail: bax@nih.gov [National Institutes of Health, Laboratory of Chemical Physics, National Institute of Diabetes and Digestive and Kidney Diseases (United States)

    2011-09-15

    Analogous to the recently introduced ARTSY method for measurement of one-bond {sup 1}H-{sup 15}N residual dipolar couplings (RDCs) in large perdeuterated proteins, we introduce methods for measurement of base {sup 13}C-{sup 1}H and {sup 15}N-{sup 1}H RDCs in protonated nucleic acids. Measurements are based on quantitative analysis of intensities in {sup 1}H-{sup 15}N and {sup 13}C-{sup 1}H TROSY-HSQC spectra, and are illustrated for a 71-nucleotide adenine riboswitch. Results compare favorably with those of conventional frequency-based measurements in terms of completeness and convenience of use. The ARTSY method derives the size of the coupling from the ratio of intensities observed in two TROSY-HSQC spectra recorded with different dephasing delays, thereby minimizing potential resonance overlap problems. Precision of the RDC measurements is limited by the signal-to-noise ratio, S/N, achievable in the 2D TROSY-HSQC reference spectrum, and is approximately given by 30/(S/N) Hz for {sup 15}N-{sup 1}H and 65/(S/N) Hz for {sup 13}C-{sup 1}H. The signal-to-noise ratio of both {sup 1}H-{sup 15}N and {sup 1}H-{sup 13}C spectra greatly benefits when water magnetization during the experiments is not perturbed, such that rapid magnetization transfer from bulk water to the nucleic acid, mediated by rapid amino and hydroxyl hydrogen exchange coupled with {sup 1}H-{sup 1}H NOE transfer, allows for fast repetition of the experiment. RDCs in the mutated helix 1 of the riboswitch are compatible with nucleotide-specifically modeled, idealized A-form geometry and a static orientation relative to the helix 2/3 pair, which differs by ca 6 Degree-Sign relative to the X-ray structure of the native riboswitch.

  5. Sleep in the Intensive Care Unit measured by polysomnography

    DEFF Research Database (Denmark)

    Andersen, J H; Boesen, Hans Christian Toft; Olsen, Karsten Skovgaard

    2013-01-01

    Sleep deprivation has deleterious effects on most organ systems. Patients in the Intensive care unit (ICU) report sleep deprivation as the second worst experience during their stay only superseded by pain. The aim of the review is to provide the clinician with knowledge of the optimal sleep-frien......-friendly care and environment.......Sleep deprivation has deleterious effects on most organ systems. Patients in the Intensive care unit (ICU) report sleep deprivation as the second worst experience during their stay only superseded by pain. The aim of the review is to provide the clinician with knowledge of the optimal sleep...

  6. Developing the PTSD Checklist-I/F for the DSM-IV (PCL-I/F: Assessing PTSD Symptom Frequency and Intensity in a Pilot Study of Male Veterans with Combat-Related PTSD

    Directory of Open Access Journals (Sweden)

    Ryan Holliday

    2015-02-01

    Full Text Available The widely used posttraumatic stress disorder (PTSD Checklist (PCL has established reliability and validity, but it does not differentiate posttraumatic symptom frequency from intensity as elements of posttraumatic symptom severity. Thus, the PCL in its existing form may not provide a comprehensive appraisal of posttraumatic symptomatology. Because of this, we modified the PCL to create the PCL-I/F that measures both frequency and intensity of PTSD symptoms via brief self-report. To establish validity and internal consistency of the PCL-I/F, we conducted a pilot study comparing PCL-I/F scores to structured diagnostic interview for PTSD (the Clinician Administered PTSD Scale [CAPS] in a male combat veteran sample of 92 participants. Statistically significant correlations between the PCL-I/F and the CAPS were found, suggesting initial validation of the PCL-I/F to screen and assess frequency and intensity of combat-related PTSD symptoms. Implications are discussed for screening and assessment of PTSD related to combat and non-combat trauma.

  7. Impact of high-intensity interval training and moderate-intensity continuous training on resting and postexercise cardiac troponin T concentration.

    Science.gov (United States)

    Nie, Jinlei; Zhang, Haifeng; Kong, Zhaowei; George, Keith; Little, Jonathan P; Tong, Tomas K; Li, Feifei; Shi, Qingde

    2018-03-01

    What is the central question of this study? Does exercise training impact resting and postexercise cardiac troponin T (cTnT) concentration? What is the main finding and its importance? This randomized controlled intervention study demonstrated that 12 weeks of either high-intensity interval training or moderate-intensity continuous training largely abolished the exercise-induced elevation in cTnT when exercise was performed at the same absolute intensity. There was no impact of training on resting cTnT or postexercise appearance of cTnT when exercise was performed at the same relative intensity. These findings provide new information that might help clinicians with decision-making in relationship to basal and postexercise values of cTnT in individuals with different training status. We evaluated the influence of 12 weeks of high-intensity interval training [HIIT; repeated 4 min cycling at 90% of maximal oxygen uptake (V̇O2max) interspersed with 3 min rest, 200-300 kJ per session, 3 or 4 days each week] and work-equivalent moderate-intensity continuous training (MICT; continuous cycling at 60% V̇O2max) on resting cardiac troponin T (cTnT) and the appearance of exercise-induced cTnT. Forty-eight sedentary obese young women were randomly assigned to HIIT, MICT or a control group. The V̇O2max and body composition were measured before and after training. At baseline, cTnT was assessed using a high-sensitivity assay at rest and immediately, 2 and 4 h after 45 min cycling at 60% V̇O2max. After a 12 week training period, cTnT was assessed before and after 45 min cycling at the same relative and absolute intensities as before training. Training led to higher V̇O2max and lower fat mass in both HIIT and MICT groups (all P training, cTnT was significantly elevated in all three groups (by 35-118%, all P training, both resting and postexercise cTnT concentrations (same relative intensity) were similar to pretraining values. In contrast, postexercise cTnT (same

  8. Measurements of the internal magnetic field on DIII-D using intensity and spacing of the motional Stark multiplet.

    Science.gov (United States)

    Pablant, N A; Burrell, K H; Groebner, R J; Kaplan, D H; Holcomb, C T

    2008-10-01

    We describe a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of Stark split D(alpha) emission from the neutral beams. This system, named B-Stark, has been recently installed on the DIII-D tokamak. To find the magnetic pitch angle, we use the ratio of the intensities of the pi(3) and sigma(1) lines. These lines originate from the same upper level and so are not dependent on the level populations. In future devices, such as ITER, this technique may have advantages over diagnostics based on MSE polarimetry. We have done an optimization of the viewing direction for the available ports on DIII-D to choose the installation location. With this placement, we have a near optimal viewing angle of 59.6 degrees from the vertical direction. All hardware has been installed for one chord, and we have been routinely taking data since January 2007. We fit the spectra using a simple Stark model in which the upper level populations of the D(alpha) transition are treated as free variables. The magnitude and direction of the magnetic field obtained using this diagnostic technique compare well with measurements from MSE polarimetry and EFIT.

  9. Input energy measurement toward warm dense matter generation using intense pulsed power generator

    Science.gov (United States)

    Hayashi, R.; Ito, T.; Ishitani, T.; Tamura, F.; Kudo, T.; Takakura, N.; Kashine, K.; Takahashi, K.; Sasaki, T.; Kikuchi, T.; Harada, Nob.; Jiang, W.; Tokuchi, A.

    2016-05-01

    In order to investigate properties of warm dense matter (WDM) in inertial confinement fusion (ICF), evaluation method for the WDM with isochoric heating on the implosion time-scale using an intense pulsed power generator ETIGO-II (∼1 TW, ∼50 ns) has been considered. In this study, the history of input energy into the sample is measured from the voltage and the current waveforms. To achieve isochoric heating, a foamed aluminum with pore sizes 600 μm and with 90% porosity was packed into a hollow glass capillary (ø 5 mm × 10 mm). The temperature of the sample is calculated from the numerical calculation using the measured input power. According to the above measurements, the input energy into a sample and the achievable temperature are estimated to be 300 J and 6000 K. It indicates that the WDM state is generated using the proposed method with ICF implosion time-scale.

  10. The measurement of neutron and neutron induced photon spectra in fusion reactor related assemblies

    CERN Document Server

    Unholzer, S; Klein, H; Seidel, K

    2002-01-01

    The spectral neutron and photon fluence (or flux) measured outside and inside of assemblies related to fusion reactor constructions are basic quantities of fusion neutronics. The comparison of measured spectra with the results of MCNP neutron and photon transport calculations allows a crucial test of evaluated nuclear data as generally used in fusion applications to be carried out. The experiments concern mixed neutron/photon fields with about the same intensity of the two components. An NE-213 scintillation spectrometer, well described by response matrices for both neutrons and photons, is used as proton-recoil and Compton spectrometer. The experiments described here in more detail address the background problematic of two applications, an iron benchmark experiment with an ns-pulsed neutron source and a deep penetration mock-up experiment for the investigation of the ITER in-board shield system. The measured spectral neutron and photon fluences are compared with spectra calculated with the MCNP code on the b...

  11. Prospective study of device-related complications in intensive care unit detected by virtual autopsy.

    Science.gov (United States)

    Wichmann, D; Heinemann, A; Zähler, S; Vogel, H; Höpker, W; Püschel, K; Kluge, S

    2018-06-01

    There has been increasing use of invasive techniques, such as extracorporeal organ support, in intensive care units (ICU), and declining autopsy rates. Thus, new measures are needed to maintain high-quality standards. We investigated the potential of computed tomography (CT)-based virtual autopsy to substitute for medical autopsy in this setting. We investigated the potential of virtual autopsy by post-mortem CT to identify complications associated with medical devices in a prospective study of patients who had died in the ICU. Clinical records were reviewed to determine the number and types of medical devices used, and findings from medical and virtual autopsies, related and unrelated to the medical devices, were compared. Medical and virtual autopsies could be performed in 61 patients (Group M/V), and virtual autopsy only in 101 patients (Group V). In Group M/V, 41 device-related complications and 30 device malpositions were identified, but only with a low inter-method agreement. Major findings unrelated to a device were identified in about 25% of patients with a high level of agreement between methods. In Group V, 8 device complications and 36 device malpositions were identified. Device-related complications are frequent in ICU patients. Virtual and medical autopsies showed clear differences in the detection of complications and device malpositions. Both methods should supplement each other rather than one alone for quality control of medical devices in the ICU. Further studies should focus on the identification of special patient populations in which virtual autopsy might be of particular benefit. NCT01541982. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  12. Phase and synchronous detector theory as applied to beam position and intensity measurements

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.

    1995-01-01

    A popular signal processing technique for beam position measurements uses the principle of amplitude-to-phase (AM/PM) conversion and phase detection. This technique processes position-sensitive beam-image-current probe-signals into output signals that are proportional to the beam's position. These same probe signals may be summed and processed in a different fashion to provide output signals that are proportional to the peak beam current which is typically referred to as beam intensity. This paper derives the transfer functions for the AM/PM beam position and peak beam current processors

  13. Effects of competition on great and blue tit reproduction: intensity and importance in relation to habitat quality.

    Science.gov (United States)

    Dhondt, André A

    2010-01-01

    1. In studies on the effect of competition in plant communities two terms are used to describe its effects: the absolute reduction in growth of an individual as a consequence of the presence of another one is called intensity, while the relative impact of competition on an individual as a proportion of the impact of the whole environment is called importance. One school of thought is that the role of competition remains constant across productivity gradients, while the other is that it decreases with increasing severity. J.B. Grace (1991. A clarification of the debate between grime and tilman. Functional Ecology, 5, 583-587.) suggested that the apparent contradiction might be solved if we acknowledge that the two schools are discussing different aspects of competition: the intensity of competition might remain constant while its importance declines with increasing severity. 2. There are no studies that compare intensity and importance of competition in bird populations between areas that differ in quality or productivity and hence it is not possible to make predictions how intensity or importance of competition would vary between them. 3. I compared variation in intensity and importance of competition of three demographic variables between five plots that differ strongly in quality for great Parus major L. and blue tit Cyanistes caeruleus (L.). 4. Both intensity and importance of competition are larger in great than in blue tit populations meaning that the effect of competition on demographic variables is stronger in great than in blue tits and that the contribution of competition to variation in these variables is relatively higher in great than in blue tits. 5. Intensity of competition is higher in low quality than in high quality plots for both species, a result not expected from studies in plant communities. 6. Importance of competition varies strongly between plots. It is larger in oak-dominated plots than in mixed deciduous plots. 7. In birds breeding density

  14. Incidence and Risk Factors for Intensive Care Unit–related Post-traumatic Stress Disorder in Veterans and Civilians

    Science.gov (United States)

    Jackson, James C.; Morandi, Alessandro; Girard, Timothy D.; Hughes, Christopher G.; Thompson, Jennifer L.; Kiehl, Amy L.; Elstad, Mark R.; Wasserstein, Mitzi L.; Goodman, Richard B.; Beckham, Jean C.; Chandrasekhar, Rameela; Dittus, Robert S.; Ely, E. Wesley; Pandharipande, Pratik P.

    2016-01-01

    Rationale: The incidence and risk factors of post-traumatic stress disorder (PTSD) related to the intensive care unit (ICU) experience have not been reported in a mixed veteran and civilian cohort. Objectives: To describe the incidence and risk factors for ICU-related PTSD in veterans and civilians. Methods: This is a prospective, observational, multicenter cohort enrolling adult survivors of critical illness after respiratory failure and/or shock from three Veterans Affairs and one civilian hospital. After classifying those with/without preexisting PTSD (i.e., PTSD before hospitalization), we then assessed all subjects for ICU-related PTSD at 3 and 12 months post hospitalization. Measurements and Main Results: Of 255 survivors, 181 and 160 subjects were assessed for ICU-related PTSD at 3- and 12-month follow-up, respectively. A high probability of ICU-related PTSD was found in up to 10% of patients at either follow-up time point, whether assessed by PTSD Checklist Event-Specific Version (score ≥ 50) or item mapping using the Diagnostic and Statistical Manual of Mental Disorders-IV (DSM-IV). In the multivariable regression, preexisting PTSD was independently associated with ICU-related PTSD at both 3 and 12 months (P < 0.001), as was preexisting depression (P < 0.03), but veteran status was not a consistent independent risk factor for ICU-related PTSD (3-month P = 0.01, 12-month P = 0.48). Conclusions: This study found around 1 in 10 ICU survivors experienced ICU-related PTSD (i.e., PTSD anchored to their critical illness) in the year after hospitalization. Preexisting PTSD and depression were strongly associated with ICU-related PTSD. PMID:26735627

  15. Evaluation of gamma-ray intensities

    International Nuclear Information System (INIS)

    Yoshizawa, Yasukazu; Inoue, Hikaru; Hoshi, Masaharu; Shizuma, Kiyoshi; Iwata, Yosei.

    1980-04-01

    Relative intensities and intensities per decay of gamma rays were evaluated for 16 nuclides, 22 Na, 24 Na, 46 Sc, 54 Mn, 60 Co, 85 Sr, 88 Y, 95 Nb, sup(108m)Ag, 134 Cs, 133 Ba, 139 Ce, sup(180m)Hf, 198 Au, 203 Hg and 207 Bi. For most of these nuclides disintegration rates can be determined by means of β-γ or X-γ coincidence method. Since decay schemes of these nuclides are established, intensities per decay of strong gamma rays were accurately evaluated by using weak beta-ray branching ratios, relative gamma-ray intensities and internal conversion coefficients. Half-lives of the nuclides were also evaluated. Use of the nuclides, therefore, are recommended for precision intensity calibration of the detectors. (author)

  16. Raman lidar measurements of water vapor and aerosols during the atmospheric radiation measurement (ARM) remote clouds sensing (RCS) intensive observation period (IOP)

    Energy Technology Data Exchange (ETDEWEB)

    Melfi, S.H.; Starr, D.O`C.; Whiteman, D. [NASA Goddard Space Flight Center, Greenbelt, MD (United States)] [and others

    1996-04-01

    The first Atmospheric Radiation Measurement (ARM) remote Cloud Study (RCS) Intensive Operations Period (IOP) was held during April 1994 at the Southern Great Plains (SGP) site. This experiment was conducted to evaluate and calibrate state-of-the-art, ground based remote sensing instruments and to use the data acquired by these instruments to validate retrieval algorithms developed under the ARM program.

  17. Measurement Uncertainty Relations for Discrete Observables: Relative Entropy Formulation

    Science.gov (United States)

    Barchielli, Alberto; Gregoratti, Matteo; Toigo, Alessandro

    2018-02-01

    We introduce a new information-theoretic formulation of quantum measurement uncertainty relations, based on the notion of relative entropy between measurement probabilities. In the case of a finite-dimensional system and for any approximate joint measurement of two target discrete observables, we define the entropic divergence as the maximal total loss of information occurring in the approximation at hand. For fixed target observables, we study the joint measurements minimizing the entropic divergence, and we prove the general properties of its minimum value. Such a minimum is our uncertainty lower bound: the total information lost by replacing the target observables with their optimal approximations, evaluated at the worst possible state. The bound turns out to be also an entropic incompatibility degree, that is, a good information-theoretic measure of incompatibility: indeed, it vanishes if and only if the target observables are compatible, it is state-independent, and it enjoys all the invariance properties which are desirable for such a measure. In this context, we point out the difference between general approximate joint measurements and sequential approximate joint measurements; to do this, we introduce a separate index for the tradeoff between the error of the first measurement and the disturbance of the second one. By exploiting the symmetry properties of the target observables, exact values, lower bounds and optimal approximations are evaluated in two different concrete examples: (1) a couple of spin-1/2 components (not necessarily orthogonal); (2) two Fourier conjugate mutually unbiased bases in prime power dimension. Finally, the entropic incompatibility degree straightforwardly generalizes to the case of many observables, still maintaining all its relevant properties; we explicitly compute it for three orthogonal spin-1/2 components.

  18. The Saturne beam measurement system for orbit corrections and high and low intensity beam acceleration

    International Nuclear Information System (INIS)

    Degueurce, L.; Nakach, A.; Sole, J.

    1980-07-01

    This paper summarizes the dipolar and multipolar correction system and the main beam diagnostics of Saturne II: wide-band RF electrostatic pick-up electrode for observation of bunches, beam position and tune measurement systems, special electrodes for observation of emittance blow-up when particles cross a resonance line. For low intensity beams, special electrodes and electronics have been developed. All this instrumentation is computer controlled

  19. Infant speech-sound discrimination testing: effects of stimulus intensity and procedural model on measures of performance.

    Science.gov (United States)

    Nozza, R J

    1987-06-01

    Performance of infants in a speech-sound discrimination task (/ba/ vs /da/) was measured at three stimulus intensity levels (50, 60, and 70 dB SPL) using the operant head-turn procedure. The procedure was modified so that data could be treated as though from a single-interval (yes-no) procedure, as is commonly done, as well as if from a sustained attention (vigilance) task. Discrimination performance changed significantly with increase in intensity, suggesting caution in the interpretation of results from infant discrimination studies in which only single stimulus intensity levels within this range are used. The assumptions made about the underlying methodological model did not change the performance-intensity relationships. However, infants demonstrated response decrement, typical of vigilance tasks, which supports the notion that the head-turn procedure is represented best by the vigilance model. Analysis then was done according to a method designed for tasks with undefined observation intervals [C. S. Watson and T. L. Nichols, J. Acoust. Soc. Am. 59, 655-668 (1976)]. Results reveal that, while group data are reasonably well represented across levels of difficulty by the fixed-interval model, there is a variation in performance as a function of time following trial onset that could lead to underestimation of performance in some cases.

  20. Infrared line intensities of chlorine monoxide

    Science.gov (United States)

    Kostiuk, T.; Faris, J. L.; Mumma, M. J.; Deming, D.; Hillman, J. J.

    1986-01-01

    Absolute infrared line intensities of several ClO lines in the rotational-vibrational (1-0) band were measured using infrared heterodyne spectroscopy near 12 microns. A measurement technique using combined ultraviolet absorption and infrared line measurements near 9.5 microns and 12 microns permitted an accurate determination of the column densities of O3 and ClO in the absorption cell and thus improved ClO line intensities. Results indicate ClO line and band intensities approximately 2.4 times lower than previous experimental results. Effects of possible failure of local thermodynamic equilibrium conditions in the absorption cell and the implication of the results for stratospheric ClO measurements in the infrared are discussed.

  1. Analysis and comparison model for measuring tropospheric scintillation intensity for Ku-band frequency in Malaysia

    Directory of Open Access Journals (Sweden)

    Mandeep JS

    2011-06-01

    Full Text Available This study has been based on understanding local propagation signal data distribution characteristics and identifying and predicting the overall impact of significant attenuating factors regarding the propagation path such as impaired propagation for a signal being transmitted. Predicting propagation impairment is important for accurate link budgeting, thereby leading to better communication network system designation. This study has thus used sample data for one year concerning beacon satellite operation in Malaysia from April 2008 to April 2009. Data concerning 12GHz frequency (Ku-band and 40° elevation angle was collected and analysed, obtaining average signal amplitude value, ÷ and also standard deviation ó which is normally measured in dB to obtain long-term scintillation intensity distribution. This analysis showed that scintillation intensity distribution followed Gaussian distribution for long-term data distribution. A prediction model was then selected based on the above; Karasawa,
    ITU-R, Van de Kamp and Otung models were compared to obtain the best prediction model performance for selected data regarding specific meteorological conditions. This study showed that the Karasawa model had the best performance for predicting scintillation intensity for the selected da ta.

  2. Intensive agriculture reduces soil biodiversity across Europe.

    Science.gov (United States)

    Tsiafouli, Maria A; Thébault, Elisa; Sgardelis, Stefanos P; de Ruiter, Peter C; van der Putten, Wim H; Birkhofer, Klaus; Hemerik, Lia; de Vries, Franciska T; Bardgett, Richard D; Brady, Mark Vincent; Bjornlund, Lisa; Jørgensen, Helene Bracht; Christensen, Sören; Hertefeldt, Tina D'; Hotes, Stefan; Gera Hol, W H; Frouz, Jan; Liiri, Mira; Mortimer, Simon R; Setälä, Heikki; Tzanopoulos, Joseph; Uteseny, Karoline; Pižl, Václav; Stary, Josef; Wolters, Volkmar; Hedlund, Katarina

    2015-02-01

    Soil biodiversity plays a key role in regulating the processes that underpin the delivery of ecosystem goods and services in terrestrial ecosystems. Agricultural intensification is known to change the diversity of individual groups of soil biota, but less is known about how intensification affects biodiversity of the soil food web as a whole, and whether or not these effects may be generalized across regions. We examined biodiversity in soil food webs from grasslands, extensive, and intensive rotations in four agricultural regions across Europe: in Sweden, the UK, the Czech Republic and Greece. Effects of land-use intensity were quantified based on structure and diversity among functional groups in the soil food web, as well as on community-weighted mean body mass of soil fauna. We also elucidate land-use intensity effects on diversity of taxonomic units within taxonomic groups of soil fauna. We found that between regions soil food web diversity measures were variable, but that increasing land-use intensity caused highly consistent responses. In particular, land-use intensification reduced the complexity in the soil food webs, as well as the community-weighted mean body mass of soil fauna. In all regions across Europe, species richness of earthworms, Collembolans, and oribatid mites was negatively affected by increased land-use intensity. The taxonomic distinctness, which is a measure of taxonomic relatedness of species in a community that is independent of species richness, was also reduced by land-use intensification. We conclude that intensive agriculture reduces soil biodiversity, making soil food webs less diverse and composed of smaller bodied organisms. Land-use intensification results in fewer functional groups of soil biota with fewer and taxonomically more closely related species. We discuss how these changes in soil biodiversity due to land-use intensification may threaten the functioning of soil in agricultural production systems. © 2014 John Wiley

  3. In vivo measurements with MOSFET detectors in oropharynx and nasopharynx intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Marcie, Serge; Charpiot, Elisabeth; Bensadoun, Rene-Jean; Ciais, Gaston; Herault, Joel; Costa, Andre; Gerard, Jean-Pierre

    2005-01-01

    Purpose: To evaluate the feasibility of in vivo measurements with metal oxide semiconductor field effect transistor (MOSFET) dosimeters for oropharynx and nasopharynx intensity-modulated radiation therapy (IMRT). Methods and Materials: During a 1-year period, in vivo measurements of the dose delivered to one or two points of the oral cavity by IMRT were obtained with MOSFET dosimeters. Measurements were obtained during each session of 48 treatment plans for 21 patients, all of whom were fitted with a custom-made mouth plate. Calculated and measured values were compared. Results: A total of 344 and 452 measurements were performed for the right and left sides, respectively, of the oral cavity. Seventy percent of the discrepancies between calculated and measured values were within ±5%. Uncertainties were due to interfraction patient positions, intrafraction patient movements, and interfraction MOSFET positions. Nevertheless, the discrepancies between the measured and calculated means were within ±5% for 92% and 95% of the right and left sides, respectively. Comparison of these discrepancies and the discrepancies between calculated values and measurements made on a phantom revealed that all differences were within ±5%. Conclusion: Our experience demonstrates the feasibility of in vivo measurements with MOSFET dosimeters for oropharynx and nasopharynx IMRT

  4. The Total Work Measured During a High Intensity Isokinetic Fatigue Test Is Associated With Anaerobic Work Capacity

    Directory of Open Access Journals (Sweden)

    Laurent Bosquet, Kenan Gouadec, Nicolas Berryman, Cyril Duclos, Vincent Gremeaux, Jean Louis Croisier

    2016-03-01

    Full Text Available The purpose of the study was to determine whether total work measured during a high intensity isokinetic fatigue test (TWFAT could be considered as a valid measure of anaerobic work capacity (AWC, such as determined by total work measured during a Wingate Anaerobic Test (TWWAnT. Twenty well-trained cyclists performed 2 randomly ordered sessions involving a high intensity isokinetic fatigue test consisting in 30 reciprocal maximal concentric contractions of knee flexors and extensors at 180°·s-1, and a Wingate Anaerobic Test. We found that TWFAT of knee extensors was largely lower than TWWAnT (4151 ± 691 vs 22313 ± 2901 J, respectively, p < 0.05, Hedge’s g = 4.27. Both measures were highly associated (r = 0.83, and the 95% limits of agreement (LoA represented 24.5% of TWWAnT. TWFAT of knee flexors (2151 ± 540 J was largely lower than TWWAnT (p < 0.05, g = 9.52. By contrast, both measures were not associated (r = 0.09, and the 95% LoA represented 31.1% of TWWAnT. Combining TWFAT of knee flexors and knee extensors into a single measure (6302 ± 818 J did not changed neither improved these observations. We still found a large difference with TWWAnT (p < 0.05, g = 5.26, a moderate association (r = 0.65 and 95% LoA representing 25.5% of TWWAnT. We concluded that TWFAT of knee extensors could be considered as a valid measure of AWC, since both measure were highly associated. However, the mean difference between both measures and their 95% LoA were too large to warrant interchangeability.

  5. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration.

    Science.gov (United States)

    Kashani, Alireza G; Olsen, Michael J; Parrish, Christopher E; Wilson, Nicholas

    2015-11-06

    In addition to precise 3D coordinates, most light detection and ranging (LIDAR) systems also record "intensity", loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of "normalization", "correction", or "calibration" techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration.

  6. Measuring the global distribution of intense convection over land with passive microwave radiometry

    Science.gov (United States)

    Spencer, R. W.; Santek, D. A.

    1985-01-01

    The global distribution of intense convective activity over land is shown to be measurable with satellite passive-microwave methods through a comparison of an empirical rain rate algorithm with a climatology of thunderstorm days for the months of June-August. With the 18 and 37 GHz channels of the Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR), the strong volume scattering effects of precipitation can be measured. Even though a single frequency (37 GHz) is responsive to the scattering signature, two frequencies are needed to remove most of the effect that variations in thermometric temperatures and soil moisture have on the brightness temperatures. Because snow cover is also a volume scatterer of microwave energy at these microwavelengths, a discrimination procedure involving four of the SMMR channels is employed to separate the rain and snow classes, based upon their differences in average thermometric temperature.

  7. The NASA Task Load Index as a measure of overall workload among neonatal, paediatric and adult intensive care nurses.

    Science.gov (United States)

    Tubbs-Cooley, Heather L; Mara, Constance A; Carle, Adam C; Gurses, Ayse P

    2018-02-12

    The NASA Task Load Index (NASA-TLX) is a subjective workload assessment scale developed for use in aviation and increasingly applied to healthcare. The scale purports to measure overall workload as a single variable calculated by summing responses to six items. Since no data address the validity of this scoring approach in health care, we evaluated the single factor structure of the NASA-TLX as a measure of overall workload among intenisive care nurses. Confirmatory factor analysis of data from two studies of nurse workload in neonatal, paediatric, and adult intensive care units. Study 1 data were obtained from 136 nurses in one neonatal intensive care unit. Study 2 data were collected from 300 nurses in 17 adult, paediatric and neonatal units. Nurses rated their workload using the NASA-TLX's paper version. A single factor model testing whether all six items measured a single overall workload variable fit least well (RMSEA = 0.14; CFI = 0.91; TLI = 0.85). A second model that specified two items as outcomes of overall workload had acceptable fit (RMSEA = 0.08; CFI = 0.97; TLI = 0.95) while a third model of four items fit best (RMSEA = 0.06; CFI > 0.99; TLI = 0.99). A summed score from four of six NASA-TLX items appears to most reliably measure a single overall workload variable among intensive care nurses. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Outbreak of Ampicillin/Piperacillin-Resistant Klebsiella Pneumoniae in a Neonatal Intensive Care Unit (NICU): Investigation and Control Measures

    OpenAIRE

    Fabbri, Giuliana; Panico, Manuela; Dallolio, Laura; Suzzi, Roberta; Ciccia, Matilde; Sandri, Fabrizio; Farruggia, Patrizia

    2013-01-01

    Klebsiella pneumoniae is a frequent cause of infectious outbreaks in Neonatal Intensive Care Units (NICUs). The aim of this paper is to describe an outbreak occurred in a 13-bed NICU and the control measures adopted in order to interrupt the chain of transmission. We described the microbiological investigations, the NICU staff compliance to the infection control measures by means of a specifically designed check-list and the control measures adopted. Six cases of primary bloodstream infection...

  9. Effect of venous dexamethasone, oral caffeine and acetaminophen on relative frequency and intensity of postdural puncture headache after spinal anesthesia.

    Science.gov (United States)

    Masoudifar, Mehrdad; Aghadavoudi, Omid; Adib, Sajjad

    2016-01-01

    Postdural puncture headache (PDPH) is a relatively common complication after regional anesthesia, especially in younger people, bothersome to patients and needs prophylaxis to prevent this complication. This study was conducted aiming to determine the preventive effect of dexamethasone plus caffeine and acetaminophen on relative frequency and intensity of PDPH after spinal anesthesia. In a clinical trial study, 90 candidates for the lower extremities orthopedic elective operation were divided into two groups of 45 individuals each. Intervention group received the compound of 500 mg acetaminophen +65 mg oral caffeine +8 mg venous dexamethasone an hour before spinal blocking, and the control group received placebo tablets + a dexamethasone equivalent volume of venous normal saline. The level of postoperative headache at the time of entrance to recovery and discharge, 6, 12, 24, 48, and 72 h postoperatively were measured based on Visual Analog Scale criterion in the two groups and then compared with each other. During the study, 24 patients in the control group and 17 patients in the intervention group were afflicted with headache; however, with no significant difference (P = 0.14). Total frequency of headache incidence was 35 times in the control group and 27 times in the intervention group (P = 0.32). Though the taking of acetaminophen + caffeine + dexamethasone is associated with a decrease in headache intensity and duration and decrease in PDPH incidence, compared with placebo, however, no essentially and statistically significant effect was produced.

  10. Determination of the X-ray mass absorption coefficient by measurement of the intensity of AgKα Compton scattered radiation

    International Nuclear Information System (INIS)

    Franzini, M.; Leoni, L.; Saitta, M.

    1976-01-01

    By utilizing a reflection geometry, an accurate mass absorption coefficient of a sample can be determined by measuring the Ag Kα Compton intensity. Intensities of Ag Kα Compton scattered radiation have been collected by using either the usual reflection geometry of a Philips PW 1450 automatic x-ray spectrometer or a more refined reflection geometry, achieved on a Philips PW 1540/10A manual x-ray spectrometer. The experimental results have shown that the relationship between the Ag Kα Compton intensity and the mass absorption is a logarithmic function. The experimental results are not in agreement with those reported in literature, but a theoretical explanation to account for this fact has not been achieved as yet. (author)

  11. Uncertainty relation and simultaneous measurements in quantum theory

    International Nuclear Information System (INIS)

    Busch, P.

    1982-01-01

    In this thesis the question for the interpretation of the uncertainty relation is picked up, and a program for the justification of its individualistic interpretation is formulated. By means of quantum mechanical models for the position and momentum measurement a justification of the interpretaton has been tried by reconstruction of the origin of the uncertainties from the conditions of the measuring devices and the determination of the relation of the measured results to the object. By means of a model of the common measurement it could be shown how the uncertainty relation results from the not eliminable mutual disturbance of the devices and the uncertainty relation for the measuring system. So finally the commutation relation is conclusive. For the illustration the split experiment is discussed, first according to Heisenberg with fixed split, then for the quantum mechanical, movable split (Bohr-Einstein). (orig./HSI) [de

  12. Intensity measurement of automotive headlamps using a photometric vision system

    Science.gov (United States)

    Patel, Balvant; Cruz, Jose; Perry, David L.; Himebaugh, Frederic G.

    1996-01-01

    Requirements for automotive head lamp luminous intensity tests are introduced. The rationale for developing a non-goniometric photometric test system is discussed. The design of the Ford photometric vision system (FPVS) is presented, including hardware, software, calibration, and system use. Directional intensity plots and regulatory test results obtained from the system are compared to corresponding results obtained from a Ford goniometric test system. Sources of error for the vision system and goniometer are discussed. Directions for new work are identified.

  13. Karoshi Related to Labor Intensity and Risk of Cardiovascular Events: A Case Report.

    Science.gov (United States)

    Liu, Ning-guo; Wang, Tao; Huang, Pingf; Qing, Zhi-qiang; Zhang, Jian-hua; Chen, Yi-jiu

    2015-10-01

    Karoshi remains one of the most troublesome issues in forensic identification. It is rather a social medicine than a clinical disease. Japanese scholars pioneered examining the relation between sud- den cardiac death (SCD) and chronic fatigue from long time and/or high-tension work. In the current case, a 55-year-old man, whose job was loading and carrying heavy cement bags, was found dead after 11 days of continuous hard work. His family members sued the cement factory for his death and claimed for compensation. The problem was the difficulty of identifying the causative relation without the precedent or the relevant regulations. However, the forensic problems were finally acknowledged after autopsy and calculation of labor intensity. The lawsuit was won as the first case pertaining to Karoshi in the Chinese court.

  14. Plasma Temperature Determination of Hydrogen Containing High-Frequency Electrodeless Lamps by Intensity Distribution Measurements of Hydrogen Molecular Band

    OpenAIRE

    Gavare, Zanda; Revalde, Gita; Skudra, Atis

    2010-01-01

    The goal of the present work was the investigation of the possibility to use intensity distribution of the Q-branch lines of the hydrogen Fulcher-α diagonal band (d3Πu−→a3∑g+ electronic transition; Q-branch with v=v′=2) to determine the temperature of hydrogen containing high-frequency electrodeless lamps (HFEDLs). The values of the rotational temperatures have been obtained from the relative intensity distributions for hydrogen-helium and hydrogen-argon HFEDLs depending on the applied curren...

  15. Prototype fiber Bragg Grattings (FBG) sensor based on intensity modulation of the laser diode low frequency vibrations measurement

    Science.gov (United States)

    Setiono, Andi; Ula, Rini Khamimatul; Hanto, Dwi; Widiyatmoko, Bambang; Purnamaningsih, Retno Wigajatri

    2016-02-01

    In general, Fiber Bragg Grating (FBG) sensor works based on observation of spectral response characteristic to detect the desired parameter. In this research, we studied intensity response characteristic of FBG to detect the dynamic strain. Experiment result show that the reflected intensity had linier relationships with dynamic strain. Based on these characteristics, we developed the FBG sensor to detect low frequency vibration. This sensor is designed by attaching the FBG on the bronze cantilever with dimensions of 85×3×0.5 mm. Measurement results showed that the sensor was able to detect vibrations in the frequency range of 7-10 Hz at temperature range of 25-45 ˚C. The measured frequency range is still within the frequency range of digging activity, therefore this vibration sensor can be applied for oil pipelines vandalisation detection system.

  16. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Physical Activity Basics Needs for Adults Needs for Children What Counts Needs for Older Adults Needs for ... Adding Physical Activity to Your Life Activities for Children Activities for Older Adults Overcoming Barriers Measuring Physical ...

  17. The Impact of Intensive Vocation-Related Course Taking on Employment Outcomes for Individuals Who Are Deaf

    Science.gov (United States)

    Cawthon, Stephanie W.; Wendel, Erica M.; Bond, Mark P.; Garberoglio, Carrie Lou

    2016-01-01

    Individuals who are deaf have historically faced significant obstacles to equity in employment. This secondary analysis of data from the second National Longitudinal Transition Study (NLTS2) examined (a) intensive vocation-related courses taken by students who are deaf and (b) their impact on long-term employment outcomes. Deaf students in general…

  18. Measuring relational security in forensic mental health services.

    Science.gov (United States)

    Chester, Verity; Alexander, Regi T; Morgan, Wendy

    2017-12-01

    Aims and method Relational security is an important component of care and risk assessment in mental health services, but the utility of available measures remains under-researched. This study analysed the psychometric properties of two relational security tools, the See Think Act (STA) scale and the Relational Security Explorer (RSE). Results The STA scale had good internal consistency and could highlight differences between occupational groups, whereas the RSE did not perform well as a psychometric measure. Clinical implications The measures provide unique and complimentary perspectives on the quality of relational security within secure services, but have some limitations. Use of the RSE should be restricted to its intended purpose; to guide team discussions about relational security, and services should refrain from collecting and aggregating this data. Until further research validates their use, relational security measurement should be multidimensional and form part of a wider process of service quality assessment.

  19. Measuring relational security in forensic mental health services

    Science.gov (United States)

    Chester, Verity; Alexander, Regi T.; Morgan, Wendy

    2017-01-01

    Aims and method Relational security is an important component of care and risk assessment in mental health services, but the utility of available measures remains under-researched. This study analysed the psychometric properties of two relational security tools, the See Think Act (STA) scale and the Relational Security Explorer (RSE). Results The STA scale had good internal consistency and could highlight differences between occupational groups, whereas the RSE did not perform well as a psychometric measure. Clinical implications The measures provide unique and complimentary perspectives on the quality of relational security within secure services, but have some limitations. Use of the RSE should be restricted to its intended purpose; to guide team discussions about relational security, and services should refrain from collecting and aggregating this data. Until further research validates their use, relational security measurement should be multidimensional and form part of a wider process of service quality assessment. PMID:29234515

  20. Evaluation of the intensity and discomfort of perioperative thirst

    Directory of Open Access Journals (Sweden)

    Isadora Pierotti

    2018-05-01

    Full Text Available Abstract Objective: To evaluate the intensity and discomfort of perioperative thirst and related factors during anesthesia recovery. Method: This is a quantitative, cross-sectional, descriptive study. Results: Of the 203 participants, 182 (89.6% reported they were thirsty. The mean intensity of thirst was 6.9 measured using a verbal numerical scale of 0 to 10 and discomfort was 7.3 on a scale of 0 to 14. All attributes evaluated by the scale were cited including dry mouth and desire to drink water (87.3%, dry lips (79.1%, thick tongue feeling (43.4%, thick saliva (56.5%, dry throat (75.2% and bad taste in the mouth (63.1%. There was a positive correlation between the intensity of thirst and discomfort assessed by the scale (Spearman coefficient: 0.474; p-value: <0.05. No correlation was found between age, length of fasting and use of opioids with the intensity of thirst and discomfort. Conclusion and implication in the clinical practice: Discomfort arising from the attributes of thirst is evidenced as the intensity of thirst increases.

  1. Improved GPS-based Satellite Relative Navigation Using Femtosecond Laser Relative Distance Measurements

    Directory of Open Access Journals (Sweden)

    Hyungjik Oh

    2016-03-01

    Full Text Available This study developed an approach for improving Carrier-phase Differential Global Positioning System (CDGPS based realtime satellite relative navigation by applying laser baseline measurement data. The robustness against the space operational environment was considered, and a Synthetic Wavelength Interferometer (SWI algorithm based on a femtosecond laser measurement model was developed. The phase differences between two laser wavelengths were combined to measure precise distance. Generated laser data were used to improve estimation accuracy for the float ambiguity of CDGPS data. Relative navigation simulations in real-time were performed using the extended Kalman filter algorithm. The GPS and laser-combined relative navigation accuracy was compared with GPS-only relative navigation solutions to determine the impact of laser data on relative navigation. In numerical simulations, the success rate of integer ambiguity resolution increased when laser data was added to GPS data. The relative navigational errors also improved five-fold and two-fold, relative to the GPS-only error, for 250 m and 5 km initial relative distances, respectively. The methodology developed in this study is suitable for application to future satellite formation-flying missions.

  2. Intensities and strong interaction attenuation of kaonic x-rays

    CERN Document Server

    Backenstoss, Gerhard; Koch, H; Povel, H P; Schwitter, A; Tauscher, Ludwig

    1974-01-01

    Relative intensities of numerous kaonic X-ray transitions have been measured for the elements C, P, S, and Cl, from which level widths due to the strong K-nucleus absorption have been determined. From these and earlier published data, optical potential parameters have been derived and possible consequences on the nuclear matter distribution are discussed. (10 refs).

  3. Measurement and numerical simulation of high intensity focused ultrasound field in water

    Science.gov (United States)

    Lee, Kang Il

    2017-11-01

    In the present study, the acoustic field of a high intensity focused ultrasound (HIFU) transducer in water was measured by using a commercially available needle hydrophone intended for HIFU use. To validate the results of hydrophone measurements, numerical simulations of HIFU fields were performed by integrating the axisymmetric Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation from the frequency-domain perspective with the help of a MATLAB-based software package developed for HIFU simulation. Quantitative values for the focal waveforms, the peak pressures, and the size of the focal spot were obtained in various regimes of linear, quasilinear, and nonlinear propagation up to the source pressure levels when the shock front was formed in the waveform. The numerical results with the HIFU simulator solving the KZK equation were compared with the experimental data and found to be in good agreement. This confirms that the numerical simulation based on the KZK equation is capable of capturing the nonlinear pressure field of therapeutic HIFU transducers well enough to make it suitable for HIFU treatment planning.

  4. The potential of detecting intermediate-scale biomass and canopy interception in a coniferous forest using cosmic-ray neutron intensity measurements and neutron transport modeling

    Science.gov (United States)

    Andreasen, M.; Looms, M. C.; Bogena, H. R.; Desilets, D.; Zreda, M. G.; Sonnenborg, T. O.; Jensen, K. H.

    2014-12-01

    The water stored in the various compartments of the terrestrial ecosystem (in snow, canopy interception, soil and litter) controls the exchange of the water and energy between the land surface and the atmosphere. Therefore, measurements of the water stored within these pools are critical for the prediction of e.g. evapotranspiration and groundwater recharge. The detection of cosmic-ray neutron intensity is a novel non-invasive method for the quantification of continuous intermediate-scale soil moisture. The footprint of the cosmic-ray neutron probe is a hemisphere of a few hectometers and subsurface depths of 10-70 cm depending on wetness. The cosmic-ray neutron method offers measurements at a scale between the point-scale measurements and large-scale satellite retrievals. The cosmic-ray neutron intensity is inversely correlated to the hydrogen stored within the footprint. Overall soil moisture represents the largest pool of hydrogen and changes in the soil moisture clearly affect the cosmic-ray neutron signal. However, the neutron intensity is also sensitive to variations of hydrogen in snow, canopy interception and biomass offering the potential to determine water content in such pools from the signal. In this study we tested the potential of determining canopy interception and biomass using cosmic-ray neutron intensity measurements within the framework of the Danish Hydrologic Observatory (HOBE) and the Terrestrial Environmental Observatories (TERENO). Continuous measurements at the ground and the canopy level, along with profile measurements were conducted at towers at forest field sites. Field experiments, including shielding the cosmic-ray neutron probes with cadmium foil (to remove lower-energy neutrons) and measuring reference intensity rates at complete water saturated conditions (on the sea close to the HOBE site), were further conducted to obtain an increased understanding of the physics controlling the cosmic-ray neutron transport and the equipment used

  5. Influences of optical-spectrum errors on excess relative intensity noise in a fiber-optic gyroscope

    Science.gov (United States)

    Zheng, Yue; Zhang, Chunxi; Li, Lijing

    2018-03-01

    The excess relative intensity noise (RIN) generated from broadband sources degrades the angular-random-walk performance of a fiber-optic gyroscope dramatically. Many methods have been proposed and managed to suppress the excess RIN. However, the properties of the excess RIN under the influences of different optical errors in the fiber-optic gyroscope have not been systematically investigated. Therefore, it is difficult for the existing RIN-suppression methods to achieve the optimal results in practice. In this work, the influences of different optical-spectrum errors on the power spectral density of the excess RIN are theoretically analyzed. In particular, the properties of the excess RIN affected by the raised-cosine-type ripples in the optical spectrum are elaborately investigated. Experimental measurements of the excess RIN corresponding to different optical-spectrum errors are in good agreement with our theoretical analysis, demonstrating its validity. This work provides a comprehensive understanding of the properties of the excess RIN under the influences of different optical-spectrum errors. Potentially, it can be utilized to optimize the configurations of the existing RIN-suppression methods by accurately evaluating the power spectral density of the excess RIN.

  6. Autonomic responses to heat pain: Heart rate, skin conductance, and their relation to verbal ratings and stimulus intensity.

    Science.gov (United States)

    Loggia, Marco L; Juneau, Mylène; Bushnell, M Catherine

    2011-03-01

    In human pain experiments, as well as in clinical settings, subjects are often asked to assess pain using scales (eg, numeric rating scales). Although most subjects have little difficulty in using these tools, some lack the necessary basic cognitive or motor skills (eg, paralyzed patients). Thus, the identification of appropriate nonverbal measures of pain has significant clinical relevance. In this study, we assessed heart rate (HR), skin conductance (SC), and verbal ratings in 39 healthy male subjects during the application of twelve 6-s heat stimuli of different intensities on the subjects' left forearm. Both HR and SC increased with more intense painful stimulation. However, HR but not SC, significantly correlated with pain ratings at the group level, suggesting that HR may be a better predictor of between-subject differences in pain than is SC. Conversely, changes in SC better predicted variations in ratings within a given individual, suggesting that it is more sensitive to relative changes in perception. The differences in findings derived from between- and within-subject analyses may result from greater within-subject variability in HR. We conclude that at least for male subjects, HR provides a better predictor of pain perception than SC, but that data should be averaged over several stimulus presentations to achieve consistent results. Nevertheless, variability among studies, and the indication that gender of both the subject and experimenter could influence autonomic results, lead us to advise caution in using autonomic or any other surrogate measures to infer pain in individuals who cannot adequately report their perception. Skin conductance is more sensitive to detect within-subject perceptual changes, but heart rate appears to better predict pain ratings at the group level. Copyright © 2010 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  7. Patients' family satisfaction with needs met at the medical intensive care unit.

    Science.gov (United States)

    Khalaila, Rabia

    2013-05-01

    The current study investigated the perceived importance and the perceived met needs of family members in the medical intensive care unit and assessed family members' satisfaction with needs met. Studies conducted throughout the world over the past 30 years indicate that family needs are still neglected. Unmet needs of family members of patients in the intensive care unit lead to dissatisfaction with care. A cross-sectional study. A total of 70 family members of critically ill patients were included in this study conducted in a medical intensive care unit in Israel between October 2007-September 2008, using a structured interview. Three outcomes measured by the Family Satisfaction in the Intensive Care Unit Inventory were regressed separately for baseline variables and family needs met subscales as measured by the Critical Care Family Needs Inventory. Multivariate linear regression analysis was used to detect factors that could have predicted each outcome. The results showed differences between the perceived importance and the perceived met needs of family members. Satisfaction with care was positively related to meeting all needs domains except the information need. However, satisfaction with information and decision-making was related only to meeting information and emotional support needs. Continued unmet needs of family members of intensive care unit patients have a negative impact on family satisfaction. Only sweeping changes in clinical practice will succeed in meeting the unmet needs of patients' families. © 2012 Blackwell Publishing Ltd.

  8. The impact of fiscal and other measures on new passenger car sales and CO2 emissions intensity. Evidence from Europe

    International Nuclear Information System (INIS)

    Ryan, Lisa; Convery, Frank; Ferreira, Susana

    2009-01-01

    This paper examines the impact of national fiscal measures in the EU (EU15) on passenger car sales and the CO 2 emissions intensity of the new car fleet over the period 1995-2004. CO 2 emissions and energy consumption from road transport have been increasing in the EU and as a result since 1999 the EU has attempted to implement a high profile policy strategy to address this problem at European level. Less prominent is the fact that Member States apply vehicle and fuel taxes, which may also be having an impact on the quantity of passenger cars sold and their CO 2 emissions intensity. Diesel vehicle sales have increased appreciably in many countries over the same period and this study makes a first attempt to examine whether Member State fiscal measures have influenced this phenomenon. This work uses a panel dataset to investigate the relationship between national vehicle and fuel taxes on new passenger car sales and the fleet CO 2 emissions intensity in EU15 over a 10-year period. Our results show that national vehicle and fuel taxes have had an impact on passenger car sales and fleet CO 2 emissions intensity and that different taxes have disparate effects. (author)

  9. Intensity Conserving Spectral Fitting

    Science.gov (United States)

    Klimchuk, J. A.; Patsourakos, S.; Tripathi, D.

    2015-01-01

    The detailed shapes of spectral line profiles provide valuable information about the emitting plasma, especially when the plasma contains an unresolved mixture of velocities, temperatures, and densities. As a result of finite spectral resolution, the intensity measured by a spectrometer is the average intensity across a wavelength bin of non-zero size. It is assigned to the wavelength position at the center of the bin. However, the actual intensity at that discrete position will be different if the profile is curved, as it invariably is. Standard fitting routines (spline, Gaussian, etc.) do not account for this difference, and this can result in significant errors when making sensitive measurements. Detection of asymmetries in solar coronal emission lines is one example. Removal of line blends is another. We have developed an iterative procedure that corrects for this effect. It can be used with any fitting function, but we employ a cubic spline in a new analysis routine called Intensity Conserving Spline Interpolation (ICSI). As the name implies, it conserves the observed intensity within each wavelength bin, which ordinary fits do not. Given the rapid convergence, speed of computation, and ease of use, we suggest that ICSI be made a standard component of the processing pipeline for spectroscopic data.

  10. Results of cosmic ray intensity measurements by the ''Luna-19'' space probe

    International Nuclear Information System (INIS)

    Chuchkov, E.A.; Lyubimov, G.P.; Myagchenkova, O.G.; Novichkova, A.D.; Pereslegina, N.V.; Kontor, N.N.; Nikolaev, A.G.

    1975-01-01

    Results are reviewed of measurements of low energy cosmic-ray characteristics obtained by means of the equipment installed on the ''Luna-19'' space station over the period from 28 November, 1971 to August 20, 1972. Proton fluxes with the energy of 1-5, 5-10, 10-40 MeV were mainly detected. A brief analysis both of individual events in cosmic rays and the general variation of intensity over the period from 1971 to 1972 is presented. Solar and geophysical data are used for the analysis. It is demonstrated that the period of the ''Luna-19'' operation corresponded to the secondary (anomalous) maximum on the decay of the solar activity in the 20th cycle. Assumptions concerning the nature of this maximum are formulated

  11. Time variations in geomagnetic intensity

    Science.gov (United States)

    Valet, Jean-Pierre

    2003-03-01

    After many years spent by paleomagnetists studying the directional behavior of the Earth's magnetic field at all possible timescales, detailed measurements of field intensity are now needed to document the variations of the entire vector and to analyze the time evolution of the field components. A significant step has been achieved by combining intensity records derived from archeological materials and from lava flows in order to extract the global field changes over the past 12 kyr. A second significant step was due to the emergence of coherent records of relative paleointensity using the remanent magnetization of sediments to retrace the evolution of the dipole field. A third step was the juxtaposition of these signals with those derived from cosmogenic isotopes. Contemporaneous with the acquisition of records, new techniques have been developed to constrain the geomagnetic origin of the signals. Much activity has also been devoted to improving the quality of determinations of absolute paleointensity from volcanic rocks with new materials, proper selection of samples, and investigations of complex changes in magnetization during laboratory experiments. Altogether these developments brought us from a situation where the field changes were restricted to the past 40 kyr to the emergence of a coherent picture of the changes in the geomagnetic dipole moment for at least the past 1 Myr. On longer timescales the field variability and its average behavior is relatively well documented for the past 400 Myr. Section 3 gives a summary of most methods and techniques that are presently used to track the field intensity changes in the past. In each case, current limits and potential promises are discussed. The section 4 describes the field variations measured so far over various timescales covered by the archeomagnetic and the paleomagnetic records. Preference has always been given to composite records and databases in order to extract and discuss major and global geomagnetic

  12. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration

    Directory of Open Access Journals (Sweden)

    Alireza G. Kashani

    2015-11-01

    Full Text Available In addition to precise 3D coordinates, most light detection and ranging (LIDAR systems also record “intensity”, loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of “normalization”, “correction”, or “calibration” techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration.

  13. Intensity of interprofessional collaboration among intensive care nurses at a tertiary hospital.

    Science.gov (United States)

    Serrano-Gemes, G; Rich-Ruiz, M

    To measure the intensity of interprofessional collaboration (IPC) in nurses of an intensive care unit (ICU) at a tertiary hospital, to check differences between the dimensions of the Intensity of Interprofessional Collaboration Questionnaire, and to identify the influence of personal variables. A cross-sectional descriptive study was conducted with 63 intensive care nurses selected by simple random sampling. Explanatory variables: age, sex, years of experience in nursing, years of experience in critical care, workday type and work shift type; variable of outcome: IPC. The IPC was measured by: Intensity of Interprofessional Collaboration Questionnaire. Descriptive and bivariate statistical analysis (IPC and its dimensions with explanatory variables). 73.8% were women, with a mean age of 46.54 (±6.076) years. The average years experience in nursing and critical care was 23.03 (±6.24) and 14.25 (±8.532), respectively. 77% had a full time and 95.1% had a rotating shift. 62.3% obtained average IPC values. Statistically significant differences were found (P<.05) between IPC (overall score) and overall assessment with years of experience in critical care. This study shows average levels of IPC; the nurses with less experience in critical care obtained higher IPC and overall assessment scores. Copyright © 2016 Sociedad Española de Enfermería Intensiva y Unidades Coronarias (SEEIUC). Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Windowless microfluidic platform based on capillary burst valves for high intensity x-ray measurements

    International Nuclear Information System (INIS)

    Vig, Asger Laurberg; Enevoldsen, Nikolaj; Thilsted, Anil Haraksingh; Eriksen, Johan; Kristensen, Anders; Haldrup, Kristoffer; Feidenhans'l, Robert; Nielsen, Martin Meedom

    2009-01-01

    We propose and describe a microfluidic system for high intensity x-ray measurements. The required open access to a microfluidic channel is provided by an out-of-plane capillary burst valve (CBV). The functionality of the out-of-plane CBV is characterized with respect to the diameter of the windowless access hole, ranging from 10 to 130 μm. Maximum driving pressures from 22 to 280 mbar corresponding to refresh rates of the exposed sample from 300 Hz to 54 kHz is demonstrated. The microfluidic system is tested at beamline ID09b at the ESRF synchrotron radiation facility in Grenoble, and x-ray scattering measurements are shown to be feasible and to require only very limited amounts of sample, <1 ml/h of measurements without recapturing of sample. With small adjustments of the present chip design, scattering angles up to 30 deg. can be achieved without shadowing effects and integration on-chip mixing and spectroscopy appears straightforward.

  15. Spatial and spectral interpolation of ground-motion intensity measure observations

    Science.gov (United States)

    Worden, Charles; Thompson, Eric M.; Baker, Jack W.; Bradley, Brendon A.; Luco, Nicolas; Wilson, David

    2018-01-01

    Following a significant earthquake, ground‐motion observations are available for a limited set of locations and intensity measures (IMs). Typically, however, it is desirable to know the ground motions for additional IMs and at locations where observations are unavailable. Various interpolation methods are available, but because IMs or their logarithms are normally distributed, spatially correlated, and correlated with each other at a given location, it is possible to apply the conditional multivariate normal (MVN) distribution to the problem of estimating unobserved IMs. In this article, we review the MVN and its application to general estimation problems, and then apply the MVN to the specific problem of ground‐motion IM interpolation. In particular, we present (1) a formulation of the MVN for the simultaneous interpolation of IMs across space and IM type (most commonly, spectral response at different oscillator periods) and (2) the inclusion of uncertain observation data in the MVN formulation. These techniques, in combination with modern empirical ground‐motion models and correlation functions, provide a flexible framework for estimating a variety of IMs at arbitrary locations.

  16. Quality control of specific patient in radiotherapy with modulated intensity

    International Nuclear Information System (INIS)

    Aberbuj, P D; Tapia Coca, R C

    2012-01-01

    In this work we comment the details of the patient specific quality controls of the first Intensity Modulated Radiotherapy treatment done at Roffo Institute. These controls consisted in two sets of measurements: absolute dose with ionization chamber and relative dose with two dosimetric systems (Gafchromic EBT2 radiochromic films and the PTW 729 ionization chambers array). Two of the filters did not pass the dosimetrical tests, and they were manufactured again. The new filters passed the tests. For the relative two-dimensional measurements the radiochromic films had a better performance than the array due to their higher spatial resolution (author)

  17. A comparison of synthetic and measured solar continuum intensities and limb darkening coefficients

    International Nuclear Information System (INIS)

    Ayres, T.R.

    1978-01-01

    Absolute continuum intensities and wavelength-dependent low-order polynomial fits to optical and infrared continuum limb darkening provide useful discriminants among single-component models of the solar photosphere. The thermal structure in best quantitative agreement with the recent center-limb measurements by Pierce and Slaughter (1977) and by Pierce et.al. (1977) is the semi-empirical model by Vernazza, Avrett and Loeser (VAL). However, the VAL model M temperatures must be scaled upward by a factor of 1.015+-0.005 to be consistent with the Labs and Neckel absolute calibration of continuum high points in the optical region 0.40-0.65 μm. (Auth.)

  18. Impact of PCA Strategies on Pain Intensity and Functional Assessment Measures in Adults with Sickle Cell Disease during Hospitalized Vaso-Occlusive Episodes

    Science.gov (United States)

    Dampier, Carlton D.; Wager, Carrie G.; Harrison, Ryan; Hsu, Lewis L.; Minniti, Caterina P.; Smith, Wally R.

    2012-01-01

    Clinical trials of sickle cell disease (SCD) pain treatment usually observe only small decrements in pain intensity during the course of hospitalization. Sub-optimal analgesic management and inadequate pain assessment methods are possible explanations for these findings. In a search for better methods for assessing inpatient SCD pain in adults, we examined several pain intensity and interference measures in both arms of a randomized controlled trial comparing two different opioid PCA therapies. Based upon longitudinal analysis of pain episodes, we found that scores from daily average Visual Analogue Scales (VAS) and several other measures, especially the Brief Pain Inventory (BPI), were sensitive to change in daily improvements in pain intensity associated with resolution of vaso-occlusive pain. In this preliminary trial, the low demand, high basal infusion (LDHI) strategy demonstrated faster, larger improvements in various measures of pain than the high demand, low basal infusion (HDLI) strategy for opioid PCA dosing, however, verification in larger studies is required. The measures and statistical approaches used in this analysis may facilitate design, reduce sample size, and improve analyses of treatment response in future SCD clinical trials of vaso-occlusive episodes. PMID:22886853

  19. Carcinogenesis related to intense pulsed light and UV exposure

    DEFF Research Database (Denmark)

    Hedelund, L; Lerche, C; Wulf, H C

    2006-01-01

    This study examines whether intense pulsed light (IPL) treatment has a carcinogenic potential itself or may influence ultraviolet (UV)-induced carcinogenesis. Secondly, it evaluates whether UV exposure may influence IPL-induced side effects. Hairless, lightly pigmented mice (n=144) received three...

  20. Lymphocyte Apoptosis in Smokers and Non-Smokers Following Different Intensity of Exercises and Relation with Lactate

    Science.gov (United States)

    PARK, KYUNG-SHIN; LEE, YANG

    2011-01-01

    Purposes of this study were 1) to examine the exercise intensity where lymphocyte apoptosis index (AI) is significantly increased in smokers and non-smokers, 2) to find out whether AI is associated with level of lactate (L). Fourteen healthy untrained smokers (≤ 1 pack year, n=7) and non-smokers (n=7) aged 18 to 26 were recruited. Each subject conducted three treadmill runs at different intensities randomly. Running distance for all three runs was equivalent to 30 minute run at 70% VO2max. AI and L were analyzed at rest (Pre), immediately after (Post), and 1 h following (1 h post) each run. Data was analyzed using two way repeated measures ANOVA. Smokers showed higher AI than non-smokers at Post in 60% (12.5±0.62% vs. 9.97±0.51, psmokers and non-smokers. The strong positive relationship between AI and L was detected (r=.739, smokers vs. r=.793, non-smokers). Smokers tend to have higher AI than non-smokers following runs at 60% and 70% VO2max, but not following a run at 80% VO2max. An increase in AI following a run at 60% VO2max indicates that lymphocyte apoptosis can be increased following moderate intensity exercise. Since L and AI at post were increased in dose-dependent manner to exercise intensity, it is suggested that an increase in lactate production during exercise might contribute to the increase in lymphocyte apoptosis. PMID:27182363

  1. A new family of standardized and symmetric indices for measuring the intensity and importance of plant neighbour effects

    NARCIS (Netherlands)

    Diaz Sierra, R.; Verwijmeren, M.; Rietkerk, M.G.; Resco de Dios, Victor; Baudena, M.

    Measurements of competition and facilitation between plants often rely upon intensity and importance indices that quantify the net effect of neighbours on the performance of a target plant. A systematic analysis of the mathematical behaviour of the indices is lacking and leads to structural

  2. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Appearance Motivational Signs Installing Music Other Ideas to Consider Tracking Stair Usage Project Checklist CDC’s Example Related Resources Walking Step It Up! Surgeon General’s ...

  3. Polarization dependence of two-photon transition intensities in rare-earth doped crystals

    Energy Technology Data Exchange (ETDEWEB)

    Le Nguyen, An-Dien [Univ. of California, Berkeley, CA (United States)

    1996-05-01

    A polarization dependence technique has been developed as a tool to investigate phonon scattering (PS), electronic Raman scattering (ERS), and two-photon absorption (TPA) transition intensities in vanadate and phosphate crystals. A general theory for the polarization dependence (PD) of two-photon transition intensities has been given. Expressions for the polarization dependent behavior of two-photon transition intensities have been tabulated for the 32 crystallographic point groups. When the wavefunctions for the initial and final states of a rare-earth doped in crystals are known, explicit PD expressions with no unknown parameters can be obtained. A spectroscopic method for measuring and interpreting phonon and ERS intensities has been developed to study PrVO4, NdVO4, ErVO4, and TmVO4 crystals. Relative phonon intensities with the polarization of the incident and scattered light arbitrarily varied were accurately predicted and subsequently used for alignment and calibration in ERS measurements in these systems for the first time. Since ERS and PS intensities generally follow different polarization curves as a function of polar angles, the two can be uniquely identified by comparing their respective polarization behavior. The most crucial application of the technique in ERS spectroscopy is the establishment of a stringent test for the Axe theory. For the first time, the F1/F2 ratio extracted from the experimental fits of the ERS intensities were compared with those predicted by theories which include both the second- and third-order contributions. Relatively good agreement between the fitted values of F1/F2 and the predicted values using the second-order theory has been found.

  4. High intensity interval and moderate continuous cycle training in a physical education programme improves health-related fitness in young females

    Directory of Open Access Journals (Sweden)

    K Mazurek

    2016-04-01

    Full Text Available The aim of the study was to investigate the effects of eight weeks of regular physical education classes supplemented with high intensity interval cycle exercise (HIIE or continuous cycle exercises of moderate intensity (CME. Forty-eight collegiate females exercising in two regular physical education classes per week were randomly assigned to two programmes (HIIE; n=24 or CME; n=24 of additional (one session of 63 minutes per week physical activity for 8 weeks. Participants performed HIIE comprising 2 series of 6x10 s sprinting with maximal pedalling cadence and active recovery pedalling with intensity 65%–75% HRmax or performed CME corresponding to 65%-75% HRmax. Before and after the 8-week programmes, anthropometric data and aero- and anaerobic capacity were measured. Two-way ANOVA revealed a significant time main effect for VO2max (p<0.001, similar improvements being found in both groups (+12% in HIIE and +11% in CME, despite body mass not changing significantly (p=0.59; +0.4% in HIIE and -0.1% in CME. A significant main time effect was found for relative fat mass (FM and fat-free mass (FFM (p<0.001 and p<0.001, respectively. A group x time interaction effect was found for relative FM and FFM (p=0.018 and p=0.018; a greater reduction in FM and greater increase in FFM were noted in the CME than the HIIE group. Improvements in anaerobic power were observed in both groups (p<0.001, but it was greater in the HIIE group (interaction effect, p=0.022. Weight loss is not mandatory for exercise-induced effects on improving aerobic and anaerobic capacity in collegiate females. Eight weeks of regular physical education classes supplemented with CME sessions are more effective in improving body composition than physical education classes supplemented with HIIE sessions. In contrast to earlier, smaller trials, similar improvements in aerobic capacity were observed following physical activity with additional HIIE or CME sessions.

  5. Levels and patterns of objectively-measured physical activity volume and intensity distribution in UK adolescents: the ROOTS study.

    Science.gov (United States)

    Collings, Paul J; Wijndaele, Katrien; Corder, Kirsten; Westgate, Kate; Ridgway, Charlotte L; Dunn, Valerie; Goodyer, Ian; Ekelund, Ulf; Brage, Soren

    2014-02-24

    Few studies have quantified levels of habitual physical activity across the entire intensity range. We aimed to describe variability in total and intensity-specific physical activity levels in UK adolescents across gender, socio-demographic, temporal and body composition strata. Physical activity energy expenditure and minutes per day (min/d) spent sedentary and in light, moderate, and vigorous intensity physical activity were assessed in 825 adolescents from the ROOTS study (43.5% boys; mean age 15.0 ± 0.30 years), by 4 days of individually calibrated combined heart rate and movement sensing. Measurement days were classified as weekday or weekend and according to the three school terms: summer (April-July), autumn (September-December), and spring (January-March). Gender and age were self-reported and area-level SES determined by postcode data. Body composition was measured by anthropometry and bio-electrical impedance. Variability in physical activity and sedentary time was analysed by linear multilevel modelling, and logistic multilevel regression was used to determine factors associated with physical inactivity (physical activity/d). During awake hours (15.8 ± 0.9 hrs/d), adolescents primarily engaged in light intensity physical activity (517 min/d) and sedentary time (364 min/d). Boys were consistently more physically active and less sedentary than girls, but gender differences were smaller at weekends, as activity levels in boys dropped more markedly when transitioning from weekday to weekend. Boys were more sedentary on both weekend days compared to during the week, whereas girls were more sedentary on Sunday but less sedentary on Saturday. In both genders light intensity physical activity was lower in spring, while moderate physical activity was lower in autumn and spring terms, compared to the summer term; sedentary time was also higher in spring than summer term. Adolescents with higher fatness engaged in less vigorous intensity physical activity

  6. Levels and patterns of objectively-measured physical activity volume and intensity distribution in UK adolescents: the ROOTS study

    Science.gov (United States)

    2014-01-01

    Background Few studies have quantified levels of habitual physical activity across the entire intensity range. We aimed to describe variability in total and intensity-specific physical activity levels in UK adolescents across gender, socio-demographic, temporal and body composition strata. Methods Physical activity energy expenditure and minutes per day (min/d) spent sedentary and in light, moderate, and vigorous intensity physical activity were assessed in 825 adolescents from the ROOTS study (43.5% boys; mean age 15.0 ± 0.30 years), by 4 days of individually calibrated combined heart rate and movement sensing. Measurement days were classified as weekday or weekend and according to the three school terms: summer (April-July), autumn (September-December), and spring (January-March). Gender and age were self-reported and area-level SES determined by postcode data. Body composition was measured by anthropometry and bio-electrical impedance. Variability in physical activity and sedentary time was analysed by linear multilevel modelling, and logistic multilevel regression was used to determine factors associated with physical inactivity (physical activity/d). Results During awake hours (15.8 ± 0.9 hrs/d), adolescents primarily engaged in light intensity physical activity (517 min/d) and sedentary time (364 min/d). Boys were consistently more physically active and less sedentary than girls, but gender differences were smaller at weekends, as activity levels in boys dropped more markedly when transitioning from weekday to weekend. Boys were more sedentary on both weekend days compared to during the week, whereas girls were more sedentary on Sunday but less sedentary on Saturday. In both genders light intensity physical activity was lower in spring, while moderate physical activity was lower in autumn and spring terms, compared to the summer term; sedentary time was also higher in spring than summer term. Adolescents with higher fatness engaged in less

  7. Pionic X-ray intensities from C, CH2 and CD2

    International Nuclear Information System (INIS)

    Daniel, H.; Seki, R.

    1980-01-01

    The relative intensities of the carbon Lsub(α) and Lsub(β) pionic X-ray lines from graphite, polyethylene, and deuterated polyethylene have been measured. No differences between CH 2 and CD 2 were observed, but differences were found between graphite and the two polyethylene targets. (orig.)

  8. The relation between rumination and temporal features of emotion intensity.

    Science.gov (United States)

    Résibois, Maxime; Kalokerinos, Elise K; Verleysen, Gregory; Kuppens, Peter; Van Mechelen, Iven; Fossati, Philippe; Verduyn, Philippe

    2018-03-01

    Intensity profiles of emotional experience over time have been found to differ primarily in explosiveness (i.e. whether the profile has a steep vs. a gentle start) and accumulation (i.e. whether intensity increases over time vs. goes back to baseline). However, the determinants of these temporal features remain poorly understood. In two studies, we examined whether emotion regulation strategies are predictive of the degree of explosiveness and accumulation of negative emotional episodes. Participants were asked to draw profiles reflecting changes in the intensity of emotions elicited either by negative social feedback in the lab (Study 1) or by negative events in daily life (Study 2). In addition, trait (Study 1 & 2), and state (Study 2) usage of a set of emotion regulation strategies was assessed. Multilevel analyses revealed that trait rumination (especially the brooding component) was positively associated with emotion accumulation (Study 1 & 2). State rumination was also positively associated with emotion accumulation and, to a lesser extent, with emotion explosiveness (Study 2). These results provide support for emotion regulation theories, which hypothesise that rumination is a central mechanism underlying the maintenance of negative emotions.

  9. Pierce-type dispersion relation for an intense relativistic electron beam interacting with a slow-wave structure

    International Nuclear Information System (INIS)

    Chen, C.

    1994-01-01

    A Pierce-type dispersion relation is derived for the interaction of an intense relativistic electron beam with a cylindrical slow-wave structure of arbitrary corrugation depth. It is shown that near a resonance, the Pierce parameter can be expressed in terms of the vacuum dispersion function and the beam current. The dispersion relation is valid in both the low-current (Compton) regime and the high-current (Raman) regime. The dispersion characteristics of the interaction, such as the linear instability growth rate and bandwidth, are analyzed for both regimes

  10. Measurements of decay heat and gamma-ray intensity of spent LWR fuel assemblies

    International Nuclear Information System (INIS)

    Vogt, J.; Agrenius, L.; Jansson, P.; Baecklin, A.; Haakansson, A.; Jacobsson, S.

    1999-01-01

    Calorimetric measurements of the decay heat of a number of BWR and PWR fuel assemblies have been performed in the pools at the Swedish Central Interim Storage Facility for Spent Nuclear Fuel, CLAB. Gamma-ray measurements, using high-resolution gamma-ray spectroscopy (HRGS), have been carried out on the same fuel assemblies in order to test if it is possible to find a simple and accurate correlation between the 137 CS -intensity and the decay heat for fuel with a cooling time longer than 10-12 years. The results up to now are very promising and may ultimately lead to a qualified method for quick and accurate determination of the decay heat of old fuel by gamma-ray measurements. By means of the gamma spectrum the operator declared data on burnup, cooling time and initial enrichment can be verified as well. CLAB provides a unique opportunity in the world to follow up the decay heat of individual fuel assemblies during several decades to come. The results will be applicable for design and operation of facilities for wet and dry interim storage and subsequent encapsulation for final disposal of the fuel. (author)

  11. Phase Noise and Intensity Noise of the Pulse Train Generated from Mode-locked Lasers in the Demodulation Measurement

    OpenAIRE

    Wu, Kan; Shum, Ping

    2010-01-01

    The phase noise and intensity noise of a pulse train are theoretically analyzed in the demodulation measurement. The effect of pulse asymmetry is discussed for the first time using Fourier series. Experimentally, photodetectors with different bandwidth and incident power levels are compared to achieve minimum pulse distortion.

  12. Analysis of distribution of PSL intensity recorded in imaging plate

    International Nuclear Information System (INIS)

    Oda, Keiji; Tsukahara, Kazutaka; Tada, Hidenori; Yamauchi, Tomoya

    2006-01-01

    Supplementary experiments and theoretical consideration have been performed about a new method for particle identification with an imaging plate, which was proposed in the previous paper. The imaging plate was exposed to 137 Cs γ-rays, 2 MeV- protons accelerated by a tandem Van de Graaff, X-rays emitted from a tube operated under the condition of 20-70 kV, as well as α- and β-rays. The frequency distribution in PSL intensity in a pixel of 100μm x 100μm was measured and the standard deviation was obtained by fitting to a Gaussian. It was confirmed that the relative standard deviation decreased with the average PSL intensity for every radiation species and that the curves were roughly divided into four groups of α-rays, protons, β-rays and photons. In the second step, these data were analyzed by plotting the square of the relative standard deviation against the average PSL intensity in full-log scale, where the relation should be expressed by a straight line with an slope of -1 provided that the deviation could be dominated only by statistical fluctuation. The data for α- and β-rays deviated from a straight line and approached to each saturated value as the average PSL intensity increased. This saturation was considered to be caused by inhomogeneity in the source intensity. It was also out that the value of interception on full-log plot would have important information about PSL reading efficiency, one of characteristic parameters of imaging plate. (author)

  13. Escaping Electrons from Intense Laser-Solid Interactions as a Function of Laser Spot Size

    Directory of Open Access Journals (Sweden)

    Rusby Dean

    2018-01-01

    Full Text Available The interaction of a high-intensity laser with a solid target produces an energetic distribution of electrons that pass into the target. These electrons reach the rear surface of the target creating strong electric potentials that act to restrict the further escape of additional electrons. The measurement of the angle, flux and spectra of the electrons that do escape gives insights to the initial interaction. Here, the escaping electrons have been measured using a differentially filtered image plate stack, from interactions with intensities from mid 1020-1017 W/cm2, where the intensity has been reduced by defocussing to increase the size of the focal spot. An increase in electron flux is initially observed as the intensity is reduced from 4x1020 to 6x1018 W/cm2. The temperature of the electron distribution is also measured and found to be relatively constant. 2D particle-in-cell modelling is used to demonstrate the importance of pre-plasma conditions in understanding these observations.

  14. Addressing Measurement Issues Related to Bullying Involvement

    Science.gov (United States)

    Casper, Deborah M.; Meter, Diana J.; Card, Noel A.

    2015-01-01

    In this article, we address measurement issues related to select aspects of bullying involvement with the goal of moving psychometrically sound measurement practices toward applied bullying research. We first provide a nontechnical introduction to psychometric considerations in measuring bullying involvement, highlighting the importance of…

  15. Motivational intensity modulates attentional scope: evidence from behavioral and ERP studies.

    Science.gov (United States)

    Liu, Lei; Zhang, Guangnan; Zhou, Renlai; Wang, Zuowei

    2014-10-01

    Previous studies have found that affective states with high motivational intensity narrow attentional scope, whereas affective states with low motivational intensity broaden attentional scope. This conclusion, however, is based on fragmented evidence based on several separate studies. The present study tests this conclusion within a single study using both behavioral (Experiment 1) and neurophysiological (Experiment 2) measures. Experiment 1 showed that individuals had the global precedence effect in the neutral affective state. However, the global precedence effect was reduced for affective states with high motivational intensity, whereas the global precedence effect was not significantly enhanced for those with low motivational intensity. Experiment 2 replicated these results with event-related potential (ERP) recording. ERP results showed that affective states with high motivational intensity induced smaller N2 and greater late positive potential (LPP) amplitudes than low motivational intensity and neutral affective states. However, no differences were found between the low motivational intensity and neutral affective states. Furthermore, smaller LPP predicted the tendency a global attentional focus in the frontal and central areas and larger LPP predicted a narrowed focus in the frontal area. The findings suggested that high motivational intensity of affective states can affect attentional scope.

  16. Relative signal intensity changes of frontal and occipital white matters on T 2 weighted axial MR image : correlation with age

    International Nuclear Information System (INIS)

    Kim, You Me; Kim, Seung Cheol

    1998-01-01

    The purpose of this study is to assess relative signal intensity changes in frontal and occipital white matter with age, as seen on T 2 weighted axial MR images. Thirty eight normal adults (20-29 years old) and 114 children (0-11 years old) were investigated. All had nonspecific neurologic symptoms and their MR images, obtained using a 1.5 T system (Signa, GE Medical Systems, Milwaukee, U.S.A.), appeared to be normal. The signal intensities of frontal and occipital white matter were evaluated on T2 weighted axial images at the level of the foramen of Monro. When the signal intensity of white matter was higher than that of gray matter, grade 0 was assigned; when the opposite situation pertained, this was graded I - III. Grade I indicated that the signal intensity of occipital white matter was lower than that of frontal white matter; grade II, that the signal intensity of white matter of both lobes was similar. When the signal intensity of frontal white matter was lower than that of occipital age, and by one year after 2 years of age, and then determined grade according to age, age distribution according to grade, and the ages at which signal intensities were similar to those of adults. On T2-weighted MR images, the signal intensity of frontal white matter ultimately shows a lower signal intensity than that of occipital white matter. (author). 11 refs., 6 figs

  17. Multiple Linear Regression Analysis Indicates Association of P-Glycoprotein Substrate or Inhibitor Character with Bitterness Intensity, Measured with a Sensor.

    Science.gov (United States)

    Yano, Kentaro; Mita, Suzune; Morimoto, Kaori; Haraguchi, Tamami; Arakawa, Hiroshi; Yoshida, Miyako; Yamashita, Fumiyoshi; Uchida, Takahiro; Ogihara, Takuo

    2015-09-01

    P-glycoprotein (P-gp) regulates absorption of many drugs in the gastrointestinal tract and their accumulation in tumor tissues, but the basis of substrate recognition by P-gp remains unclear. Bitter-tasting phenylthiocarbamide, which stimulates taste receptor 2 member 38 (T2R38), increases P-gp activity and is a substrate of P-gp. This led us to hypothesize that bitterness intensity might be a predictor of P-gp-inhibitor/substrate status. Here, we measured the bitterness intensity of a panel of P-gp substrates and nonsubstrates with various taste sensors, and used multiple linear regression analysis to examine the relationship between P-gp-inhibitor/substrate status and various physical properties, including intensity of bitter taste measured with the taste sensor. We calculated the first principal component analysis score (PC1) as the representative value of bitterness, as all taste sensor's outputs shared significant correlation. The P-gp substrates showed remarkably greater mean bitterness intensity than non-P-gp substrates. We found that Km value of P-gp substrates were correlated with molecular weight, log P, and PC1 value, and the coefficient of determination (R(2) ) of the linear regression equation was 0.63. This relationship might be useful as an aid to predict P-gp substrate status at an early stage of drug discovery. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  18. Retrospective analysis of outcomes from two intensive comprehensive aphasia programs.

    Science.gov (United States)

    Persad, Carol; Wozniak, Linda; Kostopoulos, Ellina

    2013-01-01

    Positive outcomes from intensive therapy for individuals with aphasia have been reported in the literature. Little is known about the characteristics of individuals who attend intensive comprehensive aphasia programs (ICAPs) and what factors may predict who makes clinically significant changes when attending such programs. Demographic data on participants from 6 ICAPs showed that individuals who attend these programs spanned the entire age range (from adolescence to late adulthood), but they generally tended to be middle-aged and predominantly male. Analysis of outcome data from 2 of these ICAPs found that age and gender were not significant predictors of improved outcome on measures of language ability or functional communication. However, time post onset was related to clinical improvement in functional communication as measured by the Communication Activities of Daily Living, second edition (CADL-2). In addition, for one sample, initial severity of aphasia was related to outcome on the Western Aphasia Battery-Revised, such that individuals with more severe aphasia tended to show greater recovery compared to those with mild aphasia. Initial severity of aphasia also was highly correlated with changes in CADL-2 scores. These results suggest that adults of all ages with aphasia in either the acute or chronic phase of recovery can continue to show positive improvements in language ability and functional communication with intensive treatment.

  19. The Relationships Between Internal and External Measures of Training Load and Intensity in Team Sports: A Meta-Analysis.

    Science.gov (United States)

    McLaren, Shaun J; Macpherson, Tom W; Coutts, Aaron J; Hurst, Christopher; Spears, Iain R; Weston, Matthew

    2018-03-01

    The associations between internal and external measures of training load and intensity are important in understanding the training process and the validity of specific internal measures. We aimed to provide meta-analytic estimates of the relationships, as determined by a correlation coefficient, between internal and external measures of load and intensity during team-sport training and competition. A further aim was to examine the moderating effects of training mode on these relationships. We searched six electronic databases (Scopus, Web of Science, PubMed, MEDLINE, SPORTDiscus, CINAHL) for original research articles published up to September 2017. A Boolean search phrase was created to include search terms relevant to team-sport athletes (population; 37 keywords), internal load (dependent variable; 35 keywords), and external load (independent variable; 81 keywords). Articles were considered for meta-analysis when a correlation coefficient describing the association between at least one internal and one external measure of session load or intensity, measured in the time or frequency domain, was obtained from team-sport athletes during normal training or match-play (i.e., unstructured observational study). The final data sample included 122 estimates from 13 independent studies describing 15 unique relationships between three internal and nine external measures of load and intensity. This sample included 295 athletes and 10,418 individual session observations. Internal measures were session ratings of perceived exertion (sRPE), sRPE training load (sRPE-TL), and heart-rate-derived training impulse (TRIMP). External measures were total distance (TD), the distance covered at high and very high speeds (HSRD ≥ 13.1-15.0 km h -1 and VHSRD ≥ 16.9-19.8 km h -1 , respectively), accelerometer load (AL), and the number of sustained impacts (Impacts > 2-5 G). Distinct training modes were identified as either mixed (reference condition), skills, metabolic, or

  20. Modeling of intensity-modulated continuous-wave laser absorption spectrometer systems for atmospheric CO(2) column measurements.

    Science.gov (United States)

    Lin, Bing; Ismail, Syed; Wallace Harrison, F; Browell, Edward V; Nehrir, Amin R; Dobler, Jeremy; Moore, Berrien; Refaat, Tamer; Kooi, Susan A

    2013-10-10

    The focus of this study is to model and validate the performance of intensity-modulated continuous-wave (IM-CW) CO(2) laser absorption spectrometer (LAS) systems and their CO(2) column measurements from airborne and satellite platforms. The model accounts for all fundamental physics of the instruments and their related CO(2) measurement environments, and the modeling results are presented statistically from simulation ensembles that include noise sources and uncertainties related to the LAS instruments and the measurement environments. The characteristics of simulated LAS systems are based on existing technologies and their implementation in existing systems. The modeled instruments are specifically assumed to be IM-CW LAS systems such as the Exelis' airborne multifunctional fiber laser lidar (MFLL) operating in the 1.57 μm CO(2) absorption band. Atmospheric effects due to variations in CO(2), solar radiation, and thin clouds, are also included in the model. Model results are shown to agree well with LAS atmospheric CO(2) measurement performance. For example, the relative bias errors of both MFLL simulated and measured CO(2) differential optical depths were found to agree to within a few tenths of a percent when compared to the in situ observations from the flight of 3 August 2011 over Railroad Valley (RRV), Nevada, during the summer 2011 flight campaign. In addition, the horizontal variations in the model CO(2) differential optical depths were also found to be consistent with those from MFLL measurements. In general, the modeled and measured signal-to-noise ratios (SNRs) of the CO(2) column differential optical depths (τd) agreed to within about 30%. Model simulations of a spaceborne IM-CW LAS system in a 390 km dawn/dusk orbit for CO(2) column measurements showed that with a total of 42 W of transmitted power for one offline and two different sideline channels (placed at different locations on the side of the CO(2) absorption line), the accuracy of the

  1. Quantitative Analysis of L-Edge White Line Intensities: The Influence of Saturation and Transverse Coherence

    International Nuclear Information System (INIS)

    Hahlin, A.

    2001-01-01

    We have performed x-ray absorption spectroscopy at the Fe, Ni, and Co L2,3 edges of in situ grown thin magnetic films. We compare electron yield measurements performed at SSRL and BESSY-I. Differences in the L2,3 white line intensities are found for all three elements, comparing data from the two facilities. We propose a correlation between spectral intensities and the degree of spatial coherence of the exciting radiation. The electron yield saturation effects are stronger for light with a higher degree of spatial coherence. Therefore the observed, coherence related, intensity variations are due to an increase in the absorption coefficient, and not to secondary channel related effects

  2. Quantitative analysis of L-edge white line intensities: the influence of saturation and transverse coherence.

    Science.gov (United States)

    Hahlin, A; Karis, O; Brena, B; Dunn, J H; Arvantis, D

    2001-03-01

    We have performed x-ray absorption spectroscopy at the Fe, Ni, and Co L2,3 edges of in situ grown thin magnetic films. We compare electron yield measurements performed at SSRL and BESSY-I. Differences in the L2,3 white line intensities are found for all three elements, comparing data from the two facilities. We propose a correlation between spectral intensities and the degree of spatial coherence of the exciting radiation. The electron yield saturation effects are stronger for light with a higher degree of spatial coherence. Therefore the observed, coherence related, intensity variations are due to an increase in the absorption coefficient, and not to secondary channel related effects.

  3. Validation of a measurement tool for self-assessment of teamwork in intensive care.

    Science.gov (United States)

    Weller, J; Shulruf, B; Torrie, J; Frengley, R; Boyd, M; Paul, A; Yee, B; Dzendrowskyj, P

    2013-09-01

    Teamwork is an important contributor to patient safety and a validated teamwork measurement tool could help healthcare teams identify areas for improvement and measure progress. We explored the psychometric properties of a teamwork measurement tool when used for self-assessment. We hypothesized that the tool had a valid factor structure and that scores from participants and external assessors would correlate. Forty intensive care teams (one doctor, three nurses) participated in four simulated emergencies, and each independently rated their team's performance at the end of each case using the teamwork measurement tool, without prior training in the use of the tool. We used exploratory factor analysis (EFA) and confirmatory factor analysis (CFA), and compared factor structure between participants and external assessors (using previously reported data). Scores from participants and external assessors were compared using Pearson's correlation coefficient. EFA demonstrated items loaded onto three distinct factors which were supported by the CFA. We found significant correlations between external and participant scores for overall teamwork scores and the three factors. Participants agreed with external assessors on the ranking of overall team performance but scored themselves significantly higher than external assessors. The teamwork measurement tool has a valid structure when used for self-assessment. Participant and external assessor scores correlated significantly, suggesting that participants could discriminate between different levels of performance, although leniency in self-assessed scores indicated the need for calibration. This tool could help structure reflection on teamwork and potentially facilitate self-directed, workplace-based improvement in teamwork.

  4. Consideration of fluctuation in secondary beam intensity of heavy ion beam probe measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fujisawa, A.; Iguchi, H.; Lee, S.; Hamada, Y.

    1997-01-01

    Heavy ion beam probes have capability to detect local electron density fluctuation in the interior of plasmas through the detected beam intensity fluctuation. However, the intensity fluctuation should suffer a certain degree of distortion from electron density and temperature fluctuations on the beam orbits, and as a result the signal can be quite different from the local density fluctuation. This paper will present a condition that the intensity fluctuation can be regarded as being purely local electron density fluctuation, together with discussion about the contamination of the fluctuation along the beam orbits to the beam intensity fluctuation. (author)

  5. Development of a Time-Intensity Evaluation System for Consumers: Measuring Bitterness and Retronasal Aroma of Coffee Beverages in 106 Untrained Panelists.

    Science.gov (United States)

    Gotow, Naomi; Moritani, Ami; Hayakawa, Yoshinobu; Akutagawa, Akihito; Hashimoto, Hiroshi; Kobayakawa, Tatsu

    2015-06-01

    In order to develop products that are acceptable to consumers, it is necessary to incorporate consumers' intentions into products' characteristics. Therefore, investigation of consumers' perceptions of the taste or smell of common beverages provides information that should be useful in predicting market responses. In this study, we sought to develop a time-intensity evaluation system for consumer panels. Using our system, we performed time-intensity evaluation of flavor attributes (bitterness and retronasal aroma) that consumers perceived after swallowing a coffee beverage. Additionally, we developed quantitative evaluation methods for determining whether consumer panelists can properly perform time-intensity evaluation. In every trial, we fitted an exponential function to measured intensity data for bitterness and retronasal aroma. The correlation coefficients between measured time-intensity data and the fitted exponential curves were greater than 0.8 in about 90% of trials, indicating that we had successfully developed a time-intensity system for use with consumer panelists, even after just a single training trial using a nontrained consumer. We classified participants into two groups based on their consumption of canned coffee beverages. Significant difference was observed in only AUC of sensory modality (bitterness compared with retronasal aroma) among conventional TI parameters using two-way ANOVA. However, three-way ANOVA including a time course revealed significant difference between bitterness and retronasal aroma in the high-consumption group. Moreover, the high-consumption group more easily discriminated between bitterness and retronasal aroma than the low-consumption group. This finding implied that manufacturers should select consumer panelists who are suitable for their concepts of new products. © 2015 Institute of Food Technologists®

  6. [An fMRI Study of the Brain Activation Related to Intensive Positive Emotions During Viweing Erotic Pictures in 49-74 Old Men].

    Science.gov (United States)

    Martynova, O; Portnova, G; Orlov, I

    2016-01-01

    According to psychological research erotic images are evaluated in the context of positive emotions as the most intense, most associated with emotional arousal, among the variety of pleasant and unpleasant stimuli. However it is difficult to separate areas of the brain that are related to the general emotional process from the activity of the brain areas involved in neuronal representations of reward system. The purpose of this study was to determine differences in the brain activity using functional magnetic resonance imaging (fMRI) in male subjects in evaluating an intensity of pleasant images, including erotic, or unpleasant and neutral pictures. When comparing the condition with evaluation of the pleasant erotic images with conditions containing neutral or unpleasant stimuli, a significant activation was observed in the posterior cingulate cortex; the prefrontal cortex and the right globus pallidus. An increased activity of the right anterior central gyrus was observed in the conditions related to evaluation of pleasant and neutral stimuli. Thus, in the process of evaluating the intensity of emotional images of an erotic nature the active brain areas were related not only to neuronal representations of emotions, but also to motivations and control system of emotional arousal, which should be taken into account while using erotic pictures as intensive positive emotional stimuli.

  7. Lymphocyte Apoptosis in Smokers and Non-Smokers Following Different Intensity of Exercises and Relation with Lactate.

    Science.gov (United States)

    Park, Kyung-Shin; Lee, Yang

    Purposes of this study were 1) to examine the exercise intensity where lymphocyte apoptosis index (AI) is significantly increased in smokers and non-smokers, 2) to find out whether AI is associated with level of lactate (L). Fourteen healthy untrained smokers (≤ 1 pack year, n =7) and non-smokers ( n =7) aged 18 to 26 were recruited. Each subject conducted three treadmill runs at different intensities randomly. Running distance for all three runs was equivalent to 30 minute run at 70% VO 2max . AI and L were analyzed at rest (Pre), immediately after (Post), and 1 h following (1 h post) each run. Data was analyzed using two way repeated measures ANOVA. Smokers showed higher AI than non-smokers at Post in 60% (12.5±0.62% vs. 9.97±0.51, p vs. 15.6±0.41, p smokers and non-smokers. The strong positive relationship between AI and L was detected ( r =.739, smokers vs. r =.793, non-smokers). Smokers tend to have higher AI than non-smokers following runs at 60% and 70% VO 2max, but not following a run at 80% VO 2max . An increase in AI following a run at 60% VO 2max indicates that lymphocyte apoptosis can be increased following moderate intensity exercise. Since L and AI at post were increased in dose-dependent manner to exercise intensity, it is suggested that an increase in lactate production during exercise might contribute to the increase in lymphocyte apoptosis.

  8. Intensity attenuation for active crustal regions

    Science.gov (United States)

    Allen, Trevor I.; Wald, David J.; Worden, C. Bruce

    2012-07-01

    We develop globally applicable macroseismic intensity prediction equations (IPEs) for earthquakes of moment magnitude M W 5.0-7.9 and intensities of degree II and greater for distances less than 300 km for active crustal regions. The IPEs are developed for two distance metrics: closest distance to rupture ( R rup) and hypocentral distance ( R hyp). The key objective for developing the model based on hypocentral distance—in addition to more rigorous and standard measure R rup—is to provide an IPE which can be used in near real-time earthquake response systems for earthquakes anywhere in the world, where information regarding the rupture dimensions of a fault may not be known in the immediate aftermath of the event. We observe that our models, particularly the model for the R rup distance metric, generally have low median residuals with magnitude and distance. In particular, we address whether the direct use of IPEs leads to a reduction in overall uncertainties when compared with methods which use a combination of ground-motion prediction equations and ground motion to intensity conversion equations. Finally, using topographic gradient as a proxy and median model predictions, we derive intensity-based site amplification factors. These factors lead to a small reduction of residuals at shallow gradients at strong shaking levels. However, the overall effect on total median residuals is relatively small. This is in part due to the observation that the median site condition for intensity observations used to develop these IPEs is approximately near the National Earthquake Hazard Reduction Program CD site-class boundary.

  9. Strongly intensive quantities

    International Nuclear Information System (INIS)

    Gorenstein, M. I.; Gazdzicki, M.

    2011-01-01

    Analysis of fluctuations of hadron production properties in collisions of relativistic particles profits from use of measurable intensive quantities which are independent of system size variations. The first family of such quantities was proposed in 1992; another is introduced in this paper. Furthermore we present a proof of independence of volume fluctuations for quantities from both families within the framework of the grand canonical ensemble. These quantities are referred to as strongly intensive ones. Influence of conservation laws and resonance decays is also discussed.

  10. Relative Contribution of Odour Intensity and Valence to Moral Decisions.

    Science.gov (United States)

    Cecchetto, Cinzia; Rumiati, Raffaella Ida; Parma, Valentina

    2017-01-01

    Meta-analytic evidence showed that the chemical senses affect moral decisions. However, how odours impact on morality is currently unclear. Through a set of three studies, we assess whether and how odour intensity biases moral choices (Study 1a), its psychophysiological responses (Study 1b), as well as the behavioural and psychophysiological effects of odour valence on moral choices (Study 2). Study 1a suggests that the presence of an odour plays a role in shaping moral choice. Study 1b reveals that of two iso-pleasant versions of the same neutral odour, only the one presented sub-threshold (vs. supra-threshold) favours deontological moral choices, those based on the principle of not harming others even when such harm provides benefits. As expected, this odour intensity effect is tracked by skin conductance responses, whereas no difference in cardiac activity - proxy for the valence dimension - is revealed. Study 2 suggests that the same neutral odour presented sub-threshold increases deontological choices even when compared to iso-intense ambiguous odour, perceived as pleasant or unpleasant by half of the participants, respectively. Skin conductance responses, as expected, track odour pleasantness, but cardiac activity fails to do so. Results are discussed in the context of mechanisms alternative to disgust induction underlying moral choices.

  11. Study and development of a GANIL beam intensity measurement system with high resolution (<1 nA) and with high accuracy (<1%)

    International Nuclear Information System (INIS)

    Etaix, Geoffroy

    1999-01-01

    The GANIL beam intensity measurement System enables tuning and control of the accelerator system. All along the ion beam transport line, the intensity is measured continuously with low frequency current transformers. The performance as optimized today is not satisfactory to precisely determine the accelerator efficiency on-line. A first study showed that the only sensors usable at GANIL are sensors sensitive to magnetic field (current transformers) and to electric field (capacitive probes). The theoretical study searched to predict the output of these types of sensors and enabled to define a signal treatment which corresponds to the specifications. For every sensor, this calculation is validated experimentally. Moreover this study raised the problem of calibration. The different tests completed allowed a definition of the real characteristics of the current measurements and a choice of the appropriate system. (author) [fr

  12. Negative affect as a mediator of the relationship between vigorous-intensity exercise and smoking.

    Science.gov (United States)

    Tart, Candyce D; Leyro, Teresa M; Richter, Ashley; Zvolensky, Michael J; Rosenfield, David; Smits, Jasper A J

    2010-06-01

    The present cross-sectional study evaluated whether people who engage in vigorous-intensity exercise are better able to regulate negative affective states, thereby changing core maintenance factors of smoking. Participants were a community sample of adults (n = 270) who completed self-report measures of physical activity, cigarette smoking, anxiety sensitivity, and negative affect. Consistent with hypothesis, vigorous-intensity exercise was related to lower levels of cigarette smoking, accounting for 10% of the variance in smoking. Additionally, negative affect mediated the relationship between vigorous-intensity physical activity and cigarette smoking, accounting for about 12% of this relation. Furthermore, these relationships were stronger for individuals with high anxiety sensitivity than for those with low anxiety sensitivity; including anxiety sensitivity as a moderator of the mediated relationship increased the amount of variance accounted for by negative affect to 17%. The findings are discussed in relation to developing further scientific insight into the mechanisms and pathways relevant to understanding the association among vigorous-intensity exercise, smoking, and emotional vulnerability. Copyright 2010 Elsevier Ltd. All rights reserved.

  13. Measuring Trachomatous Inflammation-Intense (TI) When Prevalence Is Low Provides Data on Infection With Chlamydia trachomatis.

    Science.gov (United States)

    Zambrano, Andrea I; Muñoz, Beatriz E; Mkocha, Harran; Dize, Laura; Gaydos, Charlotte A; Quinn, Thomas; West, Sheila K

    2017-02-01

    Clinical trachoma is the current measure of effectiveness of antibiotic and environmental improvements in trachoma endemic communities. Impact assessments measure only trachomatous inflammation-follicular (TF). Trachomatous inflammation-intense (TI) is not used for decisions on stopping mass drug administration (MDA) or achieving intervention goals. We tested the supposition that TI was not associated with Chlamydia trachomatis when disease prevalence is low. In 35 communities undergoing MDA as part of a larger project, 110 children ages 1 to 9 years were randomly selected in each community for surveys at baseline, 6, and 12 months. Both eyelids were graded for TF and TI, and a swab for detection of C. trachomatis infection was taken. Overall TF prevalence was 5% at baseline. Cases of TI alone constituted 15% of trachoma; 37% of TI cases had infection. At 6 and 12 months, the proportion of trachoma cases that had TI only was 13% and 20%; infection rates were similar to the rates in cases with TF alone. Despite low prevalence of trachoma, infection rates for TF alone and TI alone were similar at each time point. The exclusion of cases of TI alone when reporting trachoma prevalence discards additional information on infection. Trachomatous inflammation-intense could be considered as part of impact surveys.

  14. High signal intensity of fat on fast spin echo imaging

    International Nuclear Information System (INIS)

    Ogura, Akio; Yamazaki, Masaru; Hongoh, Takaharu; Inoue, Hiroshi; Ishikuro, Akihiro

    2000-01-01

    The fast spin echo (FSE) technique of producing T 2 -weighted images in greatly reduced imaging times has recently been used for routine clinical study. FSE images show contrast that is very similar in most tissues to that of conventional SE images. However, fat shows a high signal intensity that is influenced by j-coupling and the magnetization transfer effect. The purpose of this study was to assess whether the higher signal intensity of fat is different among MRI systems and to examine the effects of j-coupling and magnetization transfer on the high signal intensity of fat on FSE. The contrast in signal intensity between fat and water was measured for various echo train lengths (ETL) with and without multislicing on FSE using a contrast phantom. Measurements were obtained with four different MRI systems. In addition, the effective T 2 values of fat were calculated for the above conditions. Results indicated that contrast for fat and water was reduced with increased ETL and by using multislicing and was different among the four MRI systems. The effective T 2 values of fat were extended for increased ETL and were not dependent on multislicing. They also differed among the four MRI systems. The extent of effective T 2 values was affected by j-coupling. In this study, it was indicated that the degree of the high signal intensity of fat on FSE differed for different MRI systems. In addition, the reasons for the high signal intensity of fat on FSE were related to the effects of j-coupling and magnetization transfer. (author)

  15. Surgery for subacromial impingement syndrome in relation to intensities of occupational mechanical exposures across 10-year exposure time windows.

    Science.gov (United States)

    Dalbøge, Annett; Frost, Poul; Andersen, Johan Hviid; Svendsen, Susanne Wulff

    2018-03-01

    We aimed to identify intensities of occupational mechanical exposures (force, arm elevation and repetition) that do not entail an increased risk of surgery for subacromial impingement syndrome (SIS) even after prolonged durations of exposure. Additionally, we wanted to evaluate if exposure to hand-arm vibration (HAV) is an independent risk factor. We used data from a register-based cohort study of the entire Danish working population (n=2 374 403). During follow-up (2003-2008), 14 118 first-time events of surgery for SIS occurred. For each person, we linked register-based occupational codes (1993-2007) to a general population job exposure matrix to obtain year-by-year exposure intensities on measurement scales for force, upper arm elevation >90° and repetition and expert rated intensities of exposure to HAV. For 10-year exposure time windows, we calculated the duration of exposure at specific intensities above minimal (low, medium and high). We used a logistic regression technique equivalent to discrete survival analysis adjusting for cumulative effects of other mechanical exposures. We found indications of safe exposure intensities for repetition (median angular velocity 90° >2 min/day implied an increased risk reaching ORs of 1.7 and 1.5 after 10 years at low intensities. No associations were found for HAV. We found indications of safe exposure intensities for repetition. Any intensities of force and upper arm elevation >90° above minimal implied an increased risk across 10-year exposure time windows. No independent associations were found for HAV. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Changes in energy intensity in the manufacturing sector 1985--1991

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-15

    In this report, energy intensity is defined as the ratio of energy consumption per unit of output. Output is measured as the constant dollar of value of shipments and receipts, and two measures of energy consumption are presented in British thermal units (Btu): Offsite-Produced Energy and Total Inputs of Energy. A decrease in energy intensity from one period to another suggests an increase in energy efficiency, and vice versa. Energy efficiency can be defined and measured in various ways. Certain concepts of energy efficiency, especially those limited to equipment efficiencies, cannot be measured over time using changes in energy-intensity ratios. While improved energy efficiency will tend to reduce energy intensity, it is also true that a change in energy intensity can be due to factors unrelated to energy efficiency. For this report, energy intensity is used as a surrogate measure for energy efficiency, based on industry knowledge and current methodological analyses.

  17. The influence of pain-related expectations on intensity perception of non-painful somatosensory stimuli.

    Science.gov (United States)

    Zaman, Jonas; Wiech, Katja; Claes, Nathalie; Van Oudenhove, Lukas; Van Diest, Ilse; Vlaeyen, Johan W S

    2018-04-03

    The extent to which pain-related expectations, known to affect pain perception, also affect perception of non-painful sensations remains unclear, as well as the potential role of unpredictability in this context. In a proprioceptive fear conditioning paradigm, various arm extension movements were associated with predictable and unpredictable electrocutaneous pain or its absence. During a subsequent test phase non-painful electrocutaneous stimuli with a high or low intensity were presented during movement execution. We used hierarchical drift diffusion modeling to examine the influence of expecting pain on the perceptual decision-making process underlying intensity perception of non-painful sensations. In the first experiment (n=36), the pain stimulus was never presented during the test phase after conditioning. In the second experiment (n=39), partial reinforcement was adopted to prevent extinction of pain expectations. In both experiments, movements that were associated with (un)predictable pain led to higher pain-expectancy, self-reported fear, unpleasantness and arousal, as compared to movements that were never paired with pain (effect sizes ηp ranging from .119 - .557; all p-values threat of the pain US remained present - we found that the expectation of pain affected decision-making. Compared to the no pain condition, an a priori decision-making bias towards the high intensity decision threshold was found with the strongest bias during unpredictable pain (effect sizes ηp ranging from .469 - .504; all p-values affects inferential processes for subsequent painful but also for non-painful bodily stimuli, with unpredictability moderating these effects, and only when the threat of pain remains present due to partial reinforcement.

  18. Water-energy nexus for urban water systems: A comparative review on energy intensity and environmental impacts in relation to global water risks

    International Nuclear Information System (INIS)

    Lee, Mengshan; Keller, Arturo A.; Chiang, Pen-Chi; Den, Walter; Wang, Hongtao; Hou, Chia-Hung; Wu, Jiang; Wang, Xin; Yan, Jinyue

    2017-01-01

    Highlights: •This study quantifies the nexus as energy intensity and greenhouse gas potential. •Baseline water stress and return flow ratio are identified as water risks. •Source water accessibility significantly contributes to variations in the nexus. •Water risks have little impact on the nexus of wastewater systems. •Study on the nexus is suggested to be conducted at regional levels. -- Abstract: The importance of the interdependence between water and energy, also known as the water-energy nexus, is well recognized. The water-energy nexus is typically characterized in resource use efficiency terms such as energy intensity. This study aims to explore the quantitative results of the nexus in terms of energy intensity and environmental impacts (mainly greenhouse gas emissions) on existing water systems within urban water cycles. We also characterized the influence of water risks on the water-energy nexus, including baseline water stress (a water quantity indicator) and return flow ratio (a water quality indicator). For the 20 regions and 4 countries surveyed (including regions with low to extremely high water risks that are geographically located in Africa, Australia, Asia, Europe, and North America), their energy intensities were positively related to the water risks. Regions with higher water risks were observed to have relatively higher energy and GHG intensities associated with their water supply systems. This mainly reflected the major influence of source water accessibility on the nexus, particularly for regions requiring energy-intensive imported or groundwater supplies, or desalination. Regions that use tertiary treatment (for water reclamation or environmental protection) for their wastewater treatment systems also had relatively higher energy and GHG emission intensities, but the intensities seemed to be independent from the water risks. On-site energy recovery (e.g., biogas or waste heat) in the wastewater treatment systems offered a great

  19. Optimal entropic uncertainty relation for successive measurements ...

    Indian Academy of Sciences (India)

    measurements in quantum information theory. M D SRINIVAS ... derived by Robertson in 1929 [2] from the first principles of quantum theory, does not ... systems and may hence be referred to as 'uncertainty relations for distinct measurements'.

  20. Relative contributions of local wind and topography to the coastal upwelling intensity in the northern South China Sea

    Science.gov (United States)

    Wang, Dongxiao; Shu, Yeqiang; Xue, Huijie; Hu, Jianyu; Chen, Ju; Zhuang, Wei; Zu, TingTing; Xu, Jindian

    2014-04-01

    Topographically induced upwelling caused by the interaction between large-scale currents and topography was observed during four cruises in the northern South China Sea (NSCS) when the upwelling favorable wind retreated. Using a high-resolution version of the Princeton Ocean Model, we investigate relative contributions of local wind and topography to the upwelling intensity in the NSCS. The results show that the topographically induced upwelling is sensitive to alongshore large-scale currents, which have an important contribution to the upwelling intensity. The topographically induced upwelling is comparable with the wind-driven upwelling at surface and has a stronger contribution to the upwelling intensity than the local wind does at bottom in the near-shore shelf region. The widened shelf to the southwest of Shanwei and west of the Taiwan Banks intensifies the bottom friction, especially off Shantou, which is a key factor for topographically induced upwelling in terms of bottom Ekman transport and Ekman pumping. The local upwelling favorable wind enhances the bottom friction as well as net onshore transport along the 50 m isobath, whereas it has less influence along the 30 m isobath. This implies the local wind is more important in upwelling intensity in the offshore region than in the nearshore region. The contribution of local upwelling favorable wind on upwelling intensity is comparable with that of topography along the 50 m isobath. The effects of local upwelling favorable wind on upwelling intensity are twofold: on one hand, the wind transports surface warm water offshore, and as a compensation of mass the bottom current transports cold water onshore; on the other hand, the wind enhances the coastal current, and the bottom friction in turn increases the topographically induced upwelling intensity.

  1. An Updated Algorithm for Estimation of Pesticide Exposure Intensity in the Agricultural Health Study

    Directory of Open Access Journals (Sweden)

    Aaron Blair

    2011-12-01

    Full Text Available An algorithm developed to estimate pesticide exposure intensity for use in epidemiologic analyses was revised based on data from two exposure monitoring studies. In the first study, we estimated relative exposure intensity based on the results of measurements taken during the application of the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D (n = 88 and the insecticide chlorpyrifos (n = 17. Modifications to the algorithm weighting factors were based on geometric means (GM of post-application urine concentrations for applicators grouped by application method and use of chemically-resistant (CR gloves. Measurement data from a second study were also used to evaluate relative exposure levels associated with airblast as compared to hand spray application methods. Algorithm modifications included an increase in the exposure reduction factor for use of CR gloves from 40% to 60%, an increase in the application method weight for boom spray relative to in-furrow and for air blast relative to hand spray, and a decrease in the weight for mixing relative to the new weights assigned for application methods. The weighting factors for the revised algorithm now incorporate exposure measurements taken on Agricultural Health Study (AHS participants for the application methods and personal protective equipment (PPE commonly reported by study participants.

  2. High-intensity laser physics

    International Nuclear Information System (INIS)

    Mohideen, U.

    1993-01-01

    This thesis is a study of the effect of high intensity lasers on atoms, free electrons and the generation of X-rays from solid density plasmas. The laser produced 50 milli Joule 180 femto sec pulses at 5 Hz. This translates to a maximum intensity of 5 x 10 18 W/cm 2 . At such high fields the AC stark shifts of atoms placed at the focus is much greater than the ionization energy. The characteristics of multiphoton ionization of atoms in intense laser fields was studied by angle resolved photoelectron spectroscopy. Free electrons placed in high intensity laser fields lead to harmonic generation. This phenomenon of Nonlinear Compton Scattering was theoretically investigated. Also, when these high intensity pulses are focused on solids a hot plasma is created. This plasma is a bright source of a short X-ray pulse. The pulse-width of X-rays from these solid density plasmas was measured by time-resolved X-ray spectroscopy

  3. Examining Acoustic and Kinematic Measures of Articulatory Working Space: Effects of Speech Intensity.

    Science.gov (United States)

    Whitfield, Jason A; Dromey, Christopher; Palmer, Panika

    2018-04-18

    The purpose of this study was to examine the effect of speech intensity on acoustic and kinematic vowel space measures and conduct a preliminary examination of the relationship between kinematic and acoustic vowel space metrics calculated from continuously sampled lingual marker and formant traces. Young adult speakers produced 3 repetitions of 2 different sentences at 3 different loudness levels. Lingual kinematic and acoustic signals were collected and analyzed. Acoustic and kinematic variants of several vowel space metrics were calculated from the formant frequencies and the position of 2 lingual markers. Traditional metrics included triangular vowel space area and the vowel articulation index. Acoustic and kinematic variants of sentence-level metrics based on the articulatory-acoustic vowel space and the vowel space hull area were also calculated. Both acoustic and kinematic variants of the sentence-level metrics significantly increased with an increase in loudness, whereas no statistically significant differences in traditional vowel-point metrics were observed for either the kinematic or acoustic variants across the 3 loudness conditions. In addition, moderate-to-strong relationships between the acoustic and kinematic variants of the sentence-level vowel space metrics were observed for the majority of participants. These data suggest that both kinematic and acoustic vowel space metrics that reflect the dynamic contributions of both consonant and vowel segments are sensitive to within-speaker changes in articulation associated with manipulations of speech intensity.

  4. Low-intensity beam diagnostics with particle detectors

    Energy Technology Data Exchange (ETDEWEB)

    Rovelli, A.; Ciavola, G.; Cuttone, G.; Finocchiaro, P.; Raia, G. [INFN-LNS, Via S. Sofia 44/A Catania, 95125 (Italy); De Martinis, C.; Giove, D. [INFN-LASA, Via F.lli Cervi 201 Segrate (Midway Islands), 20090 (Italy)

    1997-01-01

    The measure of low intensity beams at low-medium energy is one of the major challenge in beam diagnostics. This subject is of great interest for the design of accelerator-based medical and radioactive beam facilities. In this paper we discuss new developments in image-based devices to measure low-intensity beams. All the investigated devices must guarantee measurement of the total beam current and its transverse distribution. {copyright} {ital 1997 American Institute of Physics.}

  5. Low-intensity beam diagnostics with particle detectors

    International Nuclear Information System (INIS)

    Rovelli, A.; Ciavola, G.; Cuttone, G.; Finocchiaro, P.; Raia, G.; De Martinis, C.; Giove, D.

    1997-01-01

    The measure of low intensity beams at low-medium energy is one of the major challenge in beam diagnostics. This subject is of great interest for the design of accelerator-based medical and radioactive beam facilities. In this paper we discuss new developments in image-based devices to measure low-intensity beams. All the investigated devices must guarantee measurement of the total beam current and its transverse distribution. copyright 1997 American Institute of Physics

  6. Comparison of maximum intensity projection and digitally reconstructed radiographic projection for carotid artery stenosis measurement

    International Nuclear Information System (INIS)

    Hyde, Derek E.; Habets, Damiaan F.; Fox, Allan J.; Gulka, Irene; Kalapos, Paul; Lee, Don H.; Pelz, David M.; Holdsworth, David W.

    2007-01-01

    Digital subtraction angiography is being supplanted by three-dimensional imaging techniques in many clinical applications, leading to extensive use of maximum intensity projection (MIP) images to depict volumetric vascular data. The MIP algorithm produces intensity profiles that are different than conventional angiograms, and can also increase the vessel-to-tissue contrast-to-noise ratio. We evaluated the effect of the MIP algorithm in a clinical application where quantitative vessel measurement is important: internal carotid artery stenosis grading. Three-dimensional computed rotational angiography (CRA) was performed on 26 consecutive symptomatic patients to verify an internal carotid artery stenosis originally found using duplex ultrasound. These volumes of data were visualized using two different postprocessing projection techniques: MIP and digitally reconstructed radiographic (DRR) projection. A DRR is a radiographic image simulating a conventional digitally subtracted angiogram, but it is derived computationally from the same CRA dataset as the MIP. By visualizing a single volume with two different projection techniques, the postprocessing effect of the MIP algorithm is isolated. Vessel measurements were made, according to the NASCET guidelines, and percentage stenosis grades were calculated. The paired t-test was used to determine if the measurement difference between the two techniques was statistically significant. The CRA technique provided an isotropic voxel spacing of 0.38 mm. The MIPs and DRRs had a mean signal-difference-to-noise-ratio of 30:1 and 26:1, respectively. Vessel measurements from MIPs were, on average, 0.17 mm larger than those from DRRs (P<0.0001). The NASCET-type stenosis grades tended to be underestimated on average by 2.4% with the MIP algorithm, although this was not statistically significant (P=0.09). The mean interobserver variability (standard deviation) of both the MIP and DRR images was 0.35 mm. It was concluded that the MIP

  7. Energy Intensity of the Electric Vehicle

    Directory of Open Access Journals (Sweden)

    Mieczysław Dziubiński

    2017-12-01

    Full Text Available Continuous energy intensity is a dependency between continuous energy intensity and energy intensity of movement. In the paper it is proposed analyze energy intensity of the movement, as the size specifying the power demand to the wheel drive and presented the balance of power of an electric car moving in the urban cycle. The object of the test was the hybrid vehicle with an internal combustion engine and electric motor. The measurements were carried out for 4 speeds and 2 driving profiles.

  8. Intra-pulse transition between ion acceleration mechanisms in intense laser-foil interactions

    Energy Technology Data Exchange (ETDEWEB)

    Padda, H.; King, M.; Gray, R. J.; Powell, H. W.; Gonzalez-Izquierdo, B.; Wilson, R.; Dance, R. J.; MacLellan, D. A.; Butler, N. M. H.; Capdessus, R.; McKenna, P., E-mail: paul.mckenna@strath.ac.uk [SUPA Department of Physics, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Stockhausen, L. C. [Centro de Laseres Pulsados (CLPU), Parque Cientifico, Calle del Adaja s/n. 37185 Villamayor, Salamanca (Spain); Carroll, D. C. [Central Laser Facility, STFC Rutherford Appleton Laboratory, Oxfordshire OX11 0QX (United Kingdom); Yuan, X. H. [Key Laboratory for Laser Plasmas (Ministry of Education) and Department of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240 (China); Collaborative Innovation Center of IFSA (CICIFSA), Shanghai Jiao Tong University, Shanghai 200240 (China); Borghesi, M. [Centre for Plasma Physics, Queens University Belfast, Belfast BT7 1NN (United Kingdom); Neely, D. [SUPA Department of Physics, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Central Laser Facility, STFC Rutherford Appleton Laboratory, Oxfordshire OX11 0QX (United Kingdom)

    2016-06-15

    Multiple ion acceleration mechanisms can occur when an ultrathin foil is irradiated with an intense laser pulse, with the dominant mechanism changing over the course of the interaction. Measurement of the spatial-intensity distribution of the beam of energetic protons is used to investigate the transition from radiation pressure acceleration to transparency-driven processes. It is shown numerically that radiation pressure drives an increased expansion of the target ions within the spatial extent of the laser focal spot, which induces a radial deflection of relatively low energy sheath-accelerated protons to form an annular distribution. Through variation of the target foil thickness, the opening angle of the ring is shown to be correlated to the point in time transparency occurs during the interaction and is maximized when it occurs at the peak of the laser intensity profile. Corresponding experimental measurements of the ring size variation with target thickness exhibit the same trends and provide insight into the intra-pulse laser-plasma evolution.

  9. Does intensity of physical activity moderate interrelationships among ...

    African Journals Online (AJOL)

    Abstract. The aim of this study was to determine whether perceived intensity of training ... intensity of training and functional capacity with various measures of health. Perceived intensity of training had marginally moderating effects on physical ...

  10. Energy intensity, target level of energy intensity, and room for improvement in energy intensity: An application to the study of regions in the EU

    International Nuclear Information System (INIS)

    Chang, Ming-Chung

    2014-01-01

    While the previous literature shows that a decline in energy intensity represents an improvement in energy use efficiency, it does not provide a target level of energy intensity, nor what room for improvement in terms of energy intensity could entail. This study establishes an indicator of such room for improvement in terms of energy intensity by measuring the difference between the target level of energy intensity and the actual energy intensity and thereby monitors energy use efficiency. The traditional indicator of energy intensity, defined as energy use over GDP, mainly estimates energy use efficiency, but is a partial effect between the energy input and GDP output. However, our proposed indicator of the room for improvement in terms of energy intensity is the total-factor effects based on the multiple-inputs model. By taking the 27 EU members to investigate their energy use efficiency using the indicator of the room for improvement in terms of energy intensity, this study concludes that an improvement in energy intensity does not fully depend on a decline in energy intensity, and we instead need to confirm whether the room for improvement in terms of energy intensity decreases. This finding is particularly relevant for energy policy-makers. - Highlights: • This paper establishes an indicator for the room for improvement in terms of energy intensity. • This study takes the 27 EU members to investigate their energy use efficiency. • A different result appears by using our proposed indicator

  11. Cryptosporidium and Giardia in Danish organic pig farms: seasonal and age-related variation in prevalence, infection intensity and species/genotypes

    DEFF Research Database (Denmark)

    Petersen, Heidi Huus; Jianmin, Wang; Katakam, Kiran K.

    2015-01-01

    Although pigs are commonly infected with Cryptosporidium spp. and Giardia duodenalis, including potentially zoonotic species or genotypes, little is known about age-related infection levels, seasonal differences and genetic variation in naturally infected pigs raised in organic management systems....... Therefore, the current study was conducted to assess seasonal and age-related variations in prevalence and infection intensity of Cryptosporidium and Giardia, evaluate zoonotic potential and uncover correlations between species/genotypes, infection intensity and faecal consistency. Shedding of oocysts...... and cysts ((oo-) cysts) was monitored at quarterly intervals (September 2011 to June 2012) in piglets (n=152), starter pigs (n=234), fatteners (n=230) and sows (n=240) from three organic farms in Denmark. (Oo-) cysts were quantified by immunofluorescence microscopy; and 56/75 subsamples from Cryptosporidium...

  12. On-line depth measurement for laser-drilled holes based on the intensity of plasma emission

    Science.gov (United States)

    Ho, Chao-Ching; Chiu, Chih-Mu; Chang, Yuan-Jen; Hsu, Jin-Chen; Kuo, Chia-Lung

    2014-09-01

    The direct time-resolved depth measurement of blind holes is extremely difficult due to the short time interval and the limited space inside the hole. This work presents a method that involves on-line plasma emission acquisition and analysis to obtain correlations between the machining processes and the optical signal output. Given that the depths of laser-machined holes can be estimated on-line using a coaxial photodiode, this was employed in our inspection system. Our experiments were conducted in air under normal atmospheric conditions without gas assist. The intensity of radiation emitted from the vaporized material was found to correlate with the depth of the hole. The results indicate that the estimated depths of the laser-drilled holes were inversely proportional to the maximum plasma light emission measured for a given laser pulse number.

  13. Decomposition analysis of the change of energy intensity of manufacturing industries in Thailand

    International Nuclear Information System (INIS)

    Chontanawat, Jaruwan; Wiboonchutikula, Paitoon; Buddhivanich, Atinat

    2014-01-01

    The study computes and analyses the sources of the change of energy intensity of the manufacturing industries in Thailand during the period (1991–2011) using the decomposition method. The Logarithmic Mean Divisia Index is computed and the results show that the energy intensity in the period (1991–2000) increased greatly from the increased energy intensity of each industry. In the more recent period (2000–2011) the energy intensity declined a little. However the decline was mainly from the structural change effect with negligible contribution from decreased energy intensity of each industry. The findings imply the need to balance industrial restructuring policies with efforts to reduce energy intensity for a sustainable economic development. Besides, there is much room for individual industries to improve their energy efficiency. Policies on restructuring energy prices and other non-price related measures should be devised to induce individual industries, particularly the highly energy intensive ones, to reduce their energy intensity. - Highlights: • Decomposing change of energy intensity of Thai manufacturing industries, 1991–2011. • 1991–2000 energy intensity rose due to increased energy intensity of each industry. • 2000–2011 energy intensity declined due mainly to the structural change effect. • Need to balance industrial restructuring policies to reduce energy intensity

  14. Electronic health record use, intensity of hospital care, and patient outcomes.

    Science.gov (United States)

    Blecker, Saul; Goldfeld, Keith; Park, Naeun; Shine, Daniel; Austrian, Jonathan S; Braithwaite, R Scott; Radford, Martha J; Gourevitch, Marc N

    2014-03-01

    Previous studies have suggested that weekend hospital care is inferior to weekday care and that this difference may be related to diminished care intensity. The purpose of this study was to determine whether a metric for measuring intensity of hospital care based on use of the electronic health record was associated with patient-level outcomes. We performed a cohort study of hospitalizations at an academic medical center. Intensity of care was defined as the hourly number of provider accessions of the electronic health record, termed "electronic health record interactions." Hospitalizations were categorized on the basis of the mean difference in electronic health record interactions between the first Friday and the first Saturday of hospitalization. We used regression models to determine the association of these categories with patient outcomes after adjusting for covariates. Electronic health record interactions decreased from Friday to Saturday in 77% of the 9051 hospitalizations included in the study. Compared with hospitalizations with no change in Friday to Saturday electronic health record interactions, the relative lengths of stay for hospitalizations with a small, moderate, and large decrease in electronic health record interactions were 1.05 (95% confidence interval [CI], 1.00-1.10), 1.11 (95% CI, 1.05-1.17), and 1.25 (95% CI, 1.15-1.35), respectively. Although a large decrease in electronic health record interactions was associated with in-hospital mortality, these findings were not significant after risk adjustment (odds ratio 1.74, 95% CI, 0.93-3.25). Intensity of inpatient care, measured by electronic health record interactions, significantly diminished from Friday to Saturday, and this decrease was associated with length of stay. Hospitals should consider monitoring and correcting temporal fluctuations in care intensity. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Beam intensity scanner system for three dimensional dose verification of IMRT

    International Nuclear Information System (INIS)

    Vahc, Young W.; Kwon, Ohyun; Park, Kwangyl; Park, Kyung R.; Yi, Byung Y.; Kim, Keun M.

    2003-01-01

    Patient dose verification is clinically one of the most important parts in the treatment delivery of radiation therapy. The three dimensional (3D) reconstruction of dose distribution delivered to target volume helps to verify patient dose and determine the physical characteristics of beams used in IMRT. Here we present beam intensity scanner (BInS) system for the pre-treatment dosimetric verification of two dimensional photon intensity. The BInS is a radiation detector with a custom-made software for dose conversion of fluorescence signals from scintillator. The scintillator is used to produce fluorescence from the irradiation of 6 MV photons on a Varian Clinac 21EX. The digitized fluoroscopic signals obtained by digital video camera-based scintillator (DVCS) will be processed by our custom made software to reproduce 3D- relative dose distribution. For the intensity modulated beam (IMB), the BInS calculates absorbed dose in absolute beam fluence which is used for the patient dose distribution. Using BInS, we performed various measurements related to IMRT and found the following: (1) The 3D-dose profiles of the IMBs measured by the BInS demonstrate good agreement with radiographic film, pin type ionization chamber and Monte Carlo simulation. (2) The delivered beam intensity is altered by the mechanical and dosimetric properties of the collimation of dynamic and/or step MLC system. This is mostly due to leaf transmission, leaf penumbra scattered photons from the round edges of leaves, and geometry of leaf. (3) The delivered dose depends on the operational detail of how to make multi leaf opening. These phenomena result in a fluence distribution that can be substantially different from the initial and calculated intensity modulation and therefore, should be taken into account by the treatment planning for accurate dose calculations delivered to the target volume in IMRT. (author)

  16. PRECISION MEASUREMENT OF MUON G-2 AND ACCELERATOR RELATED ISSUES

    International Nuclear Information System (INIS)

    BROWN, H.N.; BUNCE, G.; CAREY, R.M.; CUSHMAN, P.; DANBY, G.T.; DEBEVEC, P.T.; DEILE, M.; DENG, H.; DENINGER, W.; DHAWAN, S.K.; MENG, W.

    2001-01-01

    A precision measurement of the anomalous g value, a μ =(g-2)/2, for the positive muon has been made using high intensity protons available at the Brookhaven AGS. The result based on the 1999 data a μ =11659202(14)(6) x 10 10 (1.3ppm) is in good agreement with previous measurements and has an error one third that of the combined previous data. The current theoretical value from the standard model is a μ (SM)=11659159.6(6.7) x 10 10 (0.57 ppm) and differ by over 2.5 standard deviation with experiment. Issues with reducing systematic errors and enhancing the injection and storage efficiencies are discussed

  17. Light Penetration and Light-Intensity in Sandy Marine-Sediments Measured with Irradiance and Scalar Irradiance Fiberoptic Microprobes Rid A-1977-2009

    DEFF Research Database (Denmark)

    KUHL, M.; LASSEN, C.; JØRGENSEN, BB

    1994-01-01

    Fiber-optic microprobes for determining irradiance and scalar irradiance were used for light measurements in sandy sediments of different particle size. Intense scattering caused a maximum integral light intensity [photon scalar irradiance, E0(400 to 700 rim) and E0(700 to 880 nm)] at the sediment...... diffuse. Our results demonstrate the importance of measuring scalar irradiance when the role of light in photobiological processes in sediments, e.g. microbenthic photosynthesis, is investigated....... surface ranging from 180 % of incident collimated light in the coarsest sediment (250 to 500 mum grain size) up to 280 % in the finest sediment ( 1 mm in the coarsest sediments. Below 1 mm, light was attenuated exponentially with depth in all sediments. Light attenuation coefficients decreased...

  18. Suitability of cerebrospinal fluid as a signal-intensity reference on MRI: evaluation of signal-intensity variations in the lumbosacral dural sac

    International Nuclear Information System (INIS)

    Luoma, E.K.; Luukkonen, R.; Riihimaeki, H.A.; Raininko, R.; Manninen, H.I.; Nummi, P.J.

    1997-01-01

    The suitability of the cerebrospinal fluid (CSF) in the lumbosacral dural sac as an internal signal-intensity reference was studied on magnetic resonance imaging (MRI) of the lumbar spine using a surface coil and motion artefact suppression technique. A signal-intensity reference is needed when signal is compared between images, studies or subjects. Homogeneity of the CSF was estimated visually on T2-weighted images of 60 subjects at 1.5 T and of another 60 subjects at 0.1 T. Spines with a severely narrowed dural sac or marked scoliosis were excluded from the study to avoid partial volume effect. CSF was homogeneous in 82% and 73% of the examinations at 1.5 T and 0.1 T, respectively. The type and location of the local inhomogeneities did not relate to local narrowings of the dural sac. The signal intensity of CSF was measured in 108 examinations at 0.1 T after correcting the spatially-dependent signal-intensity nonuniformities with a phantom-based method. The signal-intensity difference between the CSF in the upper and lower lumbar dural sac was less than 10% in 73% of the examinations. The CSF in the lumbosacral dural sac can be a useful signal-intensity reference for estimation of the signal of the adjacent structures in patients without severe narrowing of the dural sac or marked scoliosis. It may contribute to assessing spinal disease processes. (orig.). With 1 fig., 3 tabs

  19. First experiences with model based iterative reconstructions influence on quantitative plaque volume and intensity measurements in coronary computed tomography angiography

    International Nuclear Information System (INIS)

    Precht, H.; Kitslaar, P.H.; Broersen, A.; Gerke, O.; Dijkstra, J.; Thygesen, J.; Egstrup, K.; Lambrechtsen, J.

    2017-01-01

    Purpose: Investigate the influence of adaptive statistical iterative reconstruction (ASIR) and the model-based IR (Veo) reconstruction algorithm in coronary computed tomography angiography (CCTA) images on quantitative measurements in coronary arteries for plaque volumes and intensities. Methods: Three patients had three independent dose reduced CCTA performed and reconstructed with 30% ASIR (CTDI vol at 6.7 mGy), 60% ASIR (CTDI vol 4.3 mGy) and Veo (CTDI vol at 1.9 mGy). Coronary plaque analysis was performed for each measured CCTA volumes, plaque burden and intensities. Results: Plaque volume and plaque burden show a decreasing tendency from ASIR to Veo as median volume for ASIR is 314 mm 3 and 337 mm 3 –252 mm 3 for Veo and plaque burden is 42% and 44% for ASIR to 39% for Veo. The lumen and vessel volume decrease slightly from 30% ASIR to 60% ASIR with 498 mm 3 –391 mm 3 for lumen volume and vessel volume from 939 mm 3 to 830 mm 3 . The intensities did not change overall between the different reconstructions for either lumen or plaque. Conclusion: We found a tendency of decreasing plaque volumes and plaque burden but no change in intensities with the use of low dose Veo CCTA (1.9 mGy) compared to dose reduced ASIR CCTA (6.7 mGy & 4.3 mGy), although more studies are warranted. - Highlights: • Veo decrease plaque volumes and plaque burden using low-dose CCTA. • Moving from ASIR 30%, ASIR 60% to Veo did not appear to influence the plaque intensities. • Studies including larger sample size are needed to investigate the effect on plaque.

  20. First experiences with model based iterative reconstructions influence on quantitative plaque volume and intensity measurements in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Kitslaar, Pieter H.; Broersen, Alexander

    2017-01-01

    Purpose: Investigate the influence of adaptive statistical iterative reconstruction (ASIR) and the model- based IR (Veo) reconstruction algorithm in coronary computed tomography angiography (CCTA) im- ages on quantitative measurements in coronary arteries for plaque volumes and intensities. Methods...

  1. Health-Related Quality of Life in Chronic Pruritus: An Analysis Related to Disease Etiology, Clinical Skin Conditions and Itch Intensity.

    Science.gov (United States)

    Warlich, Benjamin; Fritz, Fleur; Osada, Nani; Bruland, Philipp; Stumpf, Astrid; Schneider, Gudrun; Dugas, Martin; Pfleiderer, Bettina; Ständer, Sonja

    2015-01-01

    It is unknown if health-related quality of life (HRQoL) differs between diseases associated with chronic pruritus (CP). To analyze HRQoL in relation to age, gender, skin lesions (primary vs. scratch-induced secondary) and itch intensity. Consecutive patients of our itch clinic were assessed with the Dermatology Life Quality Index (DLQI) and visual analogue scale (VAS). In 510 CP patients (282 females; median age, 61.4 years), DLQI scores and VAS values were highly correlated, irrespective of the type of skin lesion. Overall, women had a lower HRQoL compared to men (females: 10.7 ± 6.7, males: 8.9 ± 6.7), but female gender was only associated with worse quality of life in patients skin lesion or underlying cause. With limitations to item bias, DLQI is a suitable instrument for estimating quality of life impairment by CP. © 2015 S. Karger AG, Basel.

  2. Brain responses to sound intensity changes dissociate depressed participants and healthy controls.

    Science.gov (United States)

    Ruohonen, Elisa M; Astikainen, Piia

    2017-07-01

    Depression is associated with bias in emotional information processing, but less is known about the processing of neutral sensory stimuli. Of particular interest is processing of sound intensity which is suggested to indicate central serotonergic function. We tested weather event-related brain potentials (ERPs) to occasional changes in sound intensity can dissociate first-episode depressed, recurrent depressed and healthy control participants. The first-episode depressed showed larger N1 amplitude to deviant sounds compared to recurrent depression group and control participants. In addition, both depression groups, but not the control group, showed larger N1 amplitude to deviant than standard sounds. Whether these manifestations of sensory over-excitability in depression are directly related to the serotonergic neurotransmission requires further research. The method based on ERPs to sound intensity change is fast and low-cost way to objectively measure brain activation and holds promise as a future diagnostic tool. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Measuring high-frequency responses of an electro-optic phase modulator based on dispersion induced phase modulation to intensity modulation conversion

    Science.gov (United States)

    Zhang, Shangjian; Wang, Heng; Wang, Yani; Zou, Xinhai; Zhang, Yali; Liu, Shuang; Liu, Yong

    2014-11-01

    We investigate the phase modulation to intensity modulation conversion in dispersive fibers for measuring frequency responses of electro-optic phase modulators, and demonstrate two typical measurements with cascade path and fold-back path. The measured results achieve an uncertainty of less than 2.8% within 20 GHz. Our measurements show stable and repeatable results because the optical carrier and its phase-modulated sidebands are affected by the same fiber impairments. The proposed method requires only dispersive fibers and works without any small-signal assumption, which is applicable for swept frequency measurement at different driving levels and operating wavelengths.

  4. Assessment of liquefaction potential during earthquakes by arias intensity

    Science.gov (United States)

    Kayen, R.E.; Mitchell, J.K.

    1997-01-01

    An Arias intensity approach to assess the liquefaction potential of soil deposits during earthquakes is proposed, using an energy-based measure of the severity of earthquake-shaking recorded on seismograms of the two horizontal components of ground motion. Values representing the severity of strong motion at depth in the soil column are associated with the liquefaction resistance of that layer, as measured by in situ penetration testing (SPT, CPT). This association results in a magnitude-independent boundary that envelopes initial liquefaction of soil in Arias intensity-normalized penetration resistance space. The Arias intensity approach is simple to apply and has proven to be highly reliable in assessing liquefaction potential. The advantages of using Arias intensity as a measure of earthquake-shaking severity in liquefaction assessment are: Arias intensity is derived from integration of the entire seismogram wave form, incorporating both the amplitude and duration elements of ground motion; all frequencies of recorded motion are considered; and Arias intensity is an appropriate measure to use when evaluating field penetration test methodologies that are inherently energy-based. Predictor equations describing the attenuation of Arias intensity as a function of earthquake magnitude and source distance are presented for rock, deep-stiff alluvium, and soft soil sites.

  5. Engineering related neutron diffraction measurements probing strains, texture and microstructure

    Energy Technology Data Exchange (ETDEWEB)

    Clausen, Bjorn [Los Alamos National Laboratory; Brown, Donald W [Los Alamos National Laboratory; Tome, Carlos N [Los Alamos National Laboratory; Balogh, Levente [Los Alamos National Laboratory; Vogel, Sven C [Los Alamos National Laboratory

    2010-01-01

    Neutron diffraction has been used for engineering applications for nearly three decades. The basis of the technique is powder diffraction following Bragg's Law. From the measured diffraction patterns information about internal, or residual, strain can be deduced from the peak positions, texture information can be extracted from the peak intensities, and finally the peak widths can provide information about the microstructure, e.g. dislocation densities and grain sizes. The strains are measured directly from changes in lattice parameters, however, in many cases it is non-trivial to determine macroscopic values of stress or strain from the measured data. The effects of intergranular strains must be considered, and combining the neutron diffraction measurements with polycrystal deformation modeling has proven invaluable in determining the overall stress and strain values of interest in designing and dimensioning engineering components. Furthelmore, the combined use of measurements and modeling has provided a tool for elucidating basic material properties, such as critical resolved shear stresses for the active deformation modes and their evolution as a function of applied deformation.

  6. Health-Related Quality of Life in Children and Adolescents with Severe Obesity after Intensive Lifestyle Treatment and at 1-Year Follow-Up

    Directory of Open Access Journals (Sweden)

    Meeke Hoedjes

    2018-04-01

    Full Text Available Objective: To examine changes in generic and weight-related, health-related quality of life (HRQoL in children and adolescents with severe obesity participating in intensive lifestyle treatment, and to examine whether changes in SDS-BMI were associated with changes in HRQoL. Methods: In this prospective observational study, a referred sample of 120 children and adolescents (8-19 years with severe obesity (SDS-BMI ≥ 3.0, or ≥ 2.3 in combination with obesity-related comorbidity received an intensive 1-year lifestyle treatment with an inpatient period in a specialized childhood obesity center. A weight-related (IWQOL-Kids and three generic (KIDSCREEN-52, PedsQL 4.0, and EuroQol HRQoL questionnaires were administered at baseline (T0, after treatment (T1, and 1 year later (T2. Generalized Linear Mixed Models and partial correlations were used to analyze changes in HRQoL and associations with changes in SDS-BMI. Results: Statistically significant improvements in generic and weight-related HRQoL overall and domain scores were observed at T1and at T2 in comparison with T0, despite partial weight regain from T1 to T2. Larger weight loss at T2 was correlated with larger improvements in physical HRQoL domains. Conclusion: Children and adolescents with severe obesity experienced long-term improvements in generic and weight-related HRQoL after participating in intensive lifestyle treatment, despite partial weight regain.

  7. Do intensity ratings and skin conductance responses reliably discriminate between different stimulus intensities in experimentally induced pain?

    Science.gov (United States)

    Breimhorst, Markus; Sandrock, Stephan; Fechir, Marcel; Hausenblas, Nadine; Geber, Christian; Birklein, Frank

    2011-01-01

    The present study addresses the question whether pain-intensity ratings and skin conductance responses (SCRs) are able to detect different intensities of phasic painful stimuli and to determine the reliability of this discrimination. For this purpose, 42 healthy participants of both genders were assigned to either electrical, mechanical, or laser heat-pain stimulation (each n = 14). A whole range of single brief painful stimuli were delivered on the right volar forearm of the dominant hand in a randomized order. Pain-intensity ratings and SCRs were analyzed. Using generalizability theory, individual and gender differences were the main contributors to the variability of both intensity ratings and SCRs. Most importantly, we showed that pain-intensity ratings are a reliable measure for the discrimination of different pain stimulus intensities in the applied modalities. The reliability of SCR was adequate when mechanical and heat stimuli were tested but failed for the discrimination of electrical stimuli. Further studies are needed to reveal the reason for this lack of accuracy for SCRs when applying electrical pain stimuli. Our study could help researchers to better understand the relationship between pain and activation of the sympathetic nervous system. Pain researchers are furthermore encouraged to consider individual and gender differences when measuring pain intensity and the concomitant SCRs in experimental settings. Copyright © 2011 American Pain Society. Published by Elsevier Inc. All rights reserved.

  8. Neutron intensity of fast reactor spent fuel

    Energy Technology Data Exchange (ETDEWEB)

    Takamatsu, Misao; Aoyama, Takafumi [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1998-03-01

    Neutron intensity of spent fuel of the JOYO Mk-II core with a burnup of 62,500 MWd/t and cooling time of 5.2 years was measured at the spent fuel storage pond. The measured data were compared with the calculated values based on the JOYO core management code system `MAGI`, and the average C/E approximately 1.2 was obtained. It was found that the axial neutron intensity didn`t simply follow the burnup distribution, and the neutron intensity was locally increased at the bottom end of the fuel region due to an accumulation of {sup 244}Cm. (author)

  9. The relative abundance of predicted genes associated with ammonia-oxidation, nitrate reduction, and biomass decomposition in mineral soil are altered by intensive timber harvest.

    Science.gov (United States)

    Mushinski, R. M.; Zhou, Y.; Gentry, T. J.; Boutton, T. W.

    2017-12-01

    Forest ecosystems in the southern United States are substantially altered by anthropogenic disturbances such as timber harvest and land conversion, with effects being observed in carbon and nutrient pools as well as biogeochemical processes. Furthermore, the desire to develop renewable energy sources in the form of biomass extraction from logging residues may result in alterations in soil community structure and function. While the impact of forest management on soil physicochemical properties of the region has been studied, its' long-term effect on soil bacterial community composition and metagenomic potential is relatively unknown, especially at deeper soil depths. This study investigates how intensive organic matter removal intensities associated with timber harvest influence decadal-scale alterations in bacterial community structure and functional potential in the upper 1-m of the soil profile, 18 years post-harvest in a Pinus taeda L. forest of eastern Texas. Amplicon sequencing of the 16S rRNA gene was used in conjunction with soil chemical analyses to evaluate treatment-induced differences in community composition and potential environmental drivers of associated change. Furthermore, functional potential was assessed by using amplicon data to make metagenomic predictions. Results indicate that increasing organic matter removal intensity leads to altered community composition and the relative abundance of dominant OTUs annotated to Burkholderia and Aciditerrimonas. The relative abundance of predicted genes associated with dissimilatory nitrate reduction and denitrification were highest in the most intensively harvested treatment while genes involved in nitrification were significantly lower in the most intensively harvested treatment. Furthermore, genes associated with glycosyltransferases were significantly reduced with increasing harvest intensity while polysaccharide lyases increased. These results imply that intensive organic matter removal may create

  10. Mini biased collimated faraday cups for measurement of intense pulsed ion beams

    International Nuclear Information System (INIS)

    He Xiaoping; Shi Lei; Zhang Jiasheng; Qiu Aici

    2000-01-01

    An analysis of principle of a biased Faraday cup for measuring ion beams density and the main reasons related to the measuring accuracy were presented. An array of mini biased collimated Faraday cups was manufactured for the measurement of ion beam density of a compact 200 keV high power ion beam source. In the experiments the maximum density of ion beam was in the center of the beam, and it was about 170 A/cm 2

  11. Sample Entropy and Traditional Measures of Heart Rate Dynamics Reveal Different Modes of Cardiovascular Control During Low Intensity Exercise

    Directory of Open Access Journals (Sweden)

    Matthias Weippert

    2014-10-01

    Full Text Available Nonlinear parameters of heart rate variability (HRV have proven their prognostic value in clinical settings, but their physiological background is not very well established. We assessed the effects of low intensity isometric (ISO and dynamic (DYN exercise of the lower limbs on heart rate matched intensity on traditional and entropy measures of HRV. Due to changes of afferent feedback under DYN and ISO a distinct autonomic response, mirrored by HRV measures, was hypothesized. Five-minute inter-beat interval measurements of 43 healthy males (26.0 ± 3.1 years were performed during rest, DYN and ISO in a randomized order. Blood pressures and rate pressure product were higher during ISO vs. DYN (p < 0.001. HRV indicators SDNN as well as low and high frequency power were significantly higher during ISO (p < 0.001 for all measures. Compared to DYN, sample entropy (SampEn was lower during ISO (p < 0.001. Concluding, contraction mode itself is a significant modulator of the autonomic cardiovascular response to exercise. Compared to DYN, ISO evokes a stronger blood pressure response and an enhanced interplay between both autonomic branches. Non-linear HRV measures indicate a more regular behavior under ISO. Results support the view of the reciprocal antagonism being only one of many modes of autonomic heart rate control. Under different conditions; the identical “end product” heart rate might be achieved by other modes such as sympathovagal co-activation as well.

  12. Short period sound speed oscillation measured by intensive XBT survey and its role on GNSS/acoustic positioning

    Science.gov (United States)

    Kido, M.; Matsui, R.; Imano, M.; Honsho, C.

    2017-12-01

    In the GNSS/acoustic measurement, sound speed in ocean plays a key role of accuracy of final positioning. We have shown than longer period sound speed undulation can be properly estimated from GNSS-A analysis itself in our previous work. In this work, we have carried out intensive XBT measurement to get temporal variation of sound speed in short period to be compared with GNSS-A derived one. In the individual temperature profile obtained by intensive XBT measurements (10 minutes interval up to 12 times of cast), clear vertical oscillation up to 20 m of amplitude in the shallow part were observed. These can be interpreted as gravitational internal wave with short-period and hence short wavelength anomaly. Kido et al. (2007) proposed that horizontal variation of the ocean structure can be considered employing five or more transponders at once if the structure is expressed by two quantities, i.e., horizontal gradient in x/y directions. However, this hypothesis requires that the variation must has a large spatial scale (> 2-5km) so that the horizontal variation can be regarded as linear within the extent of acoustic path to seafloor transponders. Therefore the wavelength of the above observed internal wave is getting important. The observed period of internal wave was 30-60 minute. However its wavelength cannot be directly measured. It must be estimate based on density profile of water column. In the comparison between sound speed change and positioning, the delay of their phases were 90 degree, which indicates that most steep horizontal slope of internal wave correspond to largest apparent positioning shift.

  13. The intensity of precipitation during extratropical cyclones in global warming simulations: a link to cyclone intensity?

    Energy Technology Data Exchange (ETDEWEB)

    Watterson, I.G. [CSIRO Atmospheric Research, Aspendale (Australia)

    2006-01-01

    Simulations of global warming over the coming century from two CSIRO GCMs are analysed to assess changes in the intensity of extratropical cyclones, and the potential role of increased latent heating associated with precipitation during cyclones. A simple surface cyclone detection scheme is applied to a four-member ensemble of simulations from the Mark 2 GCM, under rising greenhouse gas concentrations. The seasonal distribution of cyclones appears broadly realistic during 1961-1990. By 2071-2100, with 3 K global warming, numbers over 20 deg N to 70 deg N decrease by 6% in winter and 2% annually, with similar results for the south. The average intensity of cyclones, from relative central pressure and other measures, is largely unchanged however. 30-yr extremes of dynamic intensity also show little clear change, including values averaged over continents. Mean rain rates at cyclone centres are typically at least double rates from all days. Rates during cyclones increase by an average 14% in the northern winter under global warming. Rates over adjacent grid squares and during the previous day increase similarly, as do extreme rates. Results from simulations of the higher-resolution (1.8 deg grid) Mark 3 GCM are similar, with widespread increases in rain rates but not in cyclone intensity. The analyses suggest that latent heating during storms increases, as anticipated due to the increased moisture capacity of the warmer atmosphere. However, any role for enhanced heating in storm development in the GCMs is apparently masked by other factors. An exception is a 5% increase in extreme intensity around 55 deg S in Mark 3, despite decreased numbers of lows, a factor assessed using extreme value theory. Further studies with yet higher-resolution models may be needed to examine the potential realism of these results, particularly with regard to extremes at smaller scale.

  14. Towards Coupling of Macroseismic Intensity with Structural Damage Indicators

    Science.gov (United States)

    Kouteva, Mihaela; Boshnakov, Krasimir

    2016-04-01

    Knowledge on basic data of ground motion acceleration time histories during earthquakes is essential to understanding the earthquake resistant behaviour of structures. Peak and integral ground motion parameters such as peak ground motion values (acceleration, velocity and displacement), measures of the frequency content of ground motion, duration of strong shaking and various intensity measures play important roles in seismic evaluation of existing facilities and design of new systems. Macroseismic intensity is an earthquake measure related to seismic hazard and seismic risk description. Having detailed ideas on the correlations between the earthquake damage potential and macroseismic intensity is an important issue in engineering seismology and earthquake engineering. Reliable earthquake hazard estimation is the major prerequisite to successful disaster risk management. The usage of advanced earthquake engineering approaches for structural response modelling is essential for reliable evaluation of the accumulated damages in the existing buildings and structures due to the history of seismic actions, occurred during their lifetime. Full nonlinear analysis taking into account single event or series of earthquakes and the large set of elaborated damage indices are suitable contemporary tools to cope with this responsible task. This paper presents some results on the correlation between observational damage states, ground motion parameters and selected analytical damage indices. Damage indices are computed on the base of nonlinear time history analysis of test reinforced structure, characterising the building stock of the Mediterranean region designed according the earthquake resistant requirements in mid XX-th century.

  15. Decomposition of useful work intensity: The EU (European Union)-15 countries from 1960 to 2009

    International Nuclear Information System (INIS)

    Serrenho, André Cabrera; Sousa, Tânia; Warr, Benjamin; Ayres, Robert U.; Domingos, Tiago

    2014-01-01

    Energy intensity measures, defined as the ratio of energy use to gross domestic product of a country, are widely used to study the productivity of energy use in an economy. Unlike conventional primary and/or final energy intensities, useful work intensity (useful work/gross domestic product) addresses the problem of aggregating in a single measure the different energy forms used, and allows for a clear distinction between thermodynamic efficiencies and structural changes in the demand for energy end-uses. Here, our aim is twofold: (1) Disclose the factors that control the useful work intensities across the EU-15 countries over the deindustrialization process, performing a decomposition of the useful work intensities from 1960 to 2009. (2) Describe a methodology for the automatization of useful work accounting, based on a general mapping of energy end-uses from IEA (International Energy Agency) energy balances. We show that, in contrast to the other conventional energy intensity measures, useful work intensity depends only on the intensity of high temperature heat uses and the relative size of residential energy needs. Aggregate thermodynamic efficiencies slightly increased as a consequence of technological improvements, but were negatively affected by deindustrialization, as a consequence of a transition to less efficient and productive energy uses. - Highlights: • We provide an automated useful work accounting methodology from IEA energy balances. • We provide an estimation of 2nd law efficiencies for EU-15 countries since 1960. • This methodology is applied to EU-15 from 1960 to 2009. • Useful work intensity depends only on high temperature heat and residential uses. • Thermodynamic 2nd law efficiencies were negatively affected by deindustrialization

  16. Analytical theory of intensity fluctuations in SASE

    Energy Technology Data Exchange (ETDEWEB)

    Yu, L.H.; Krinsky, S. [Brookhaven National Lab., Upton, NY (United States). National Synchrotron Light Source

    1997-07-01

    Recent advances in SASE experiments stimulate interest in quantitative comparison of measurements with theory. Extending the previous analysis of the SASE intensity in guided modes, the authors provide an analytical description of the intensity fluctuations by calculating intensity correlation functions in the frequency domain. Comparison of the results with experiment yields new insight into the SASE process.

  17. Impact of PCA Strategies on Pain Intensity and Functional Assessment Measures in Adults with Sickle Cell Disease during Hospitalized Vaso-Occlusive Episodes

    OpenAIRE

    Dampier, Carlton D.; Wager, Carrie G.; Harrison, Ryan; Hsu, Lewis L.; Minniti, Caterina P.; Smith, Wally R.

    2012-01-01

    Clinical trials of sickle cell disease (SCD) pain treatment usually observe only small decrements in pain intensity during the course of hospitalization. Sub-optimal analgesic management and inadequate pain assessment methods are possible explanations for these findings. In a search for better methods for assessing inpatient SCD pain in adults, we examined several pain intensity and interference measures in both arms of a randomized controlled trial comparing two different opioid PCA therapie...

  18. A measure of satisfaction with food-related life

    DEFF Research Database (Denmark)

    Grunert, Klaus G.; Dean, Moira; Raats, Monique M.

    2007-01-01

    A measure of satisfaction with food-related life is developed and tested in three studies in eight European countries. Five items are retained from an original pool of seven; these items exhibit good reliability as measured by Cronbach's alpha, good temporal stability, convergent validity with two...... related measures, and construct validity as indicated by relationships with other indicators of quality of life, including the Satisfaction With Life and the SF-8 scales. It is concluded that this scale will be useful in studies trying to identify factors contributing to satisfaction with food...

  19. Characteristics of ionization chambers for intense pulsed x-rays and Co-60 #betta#-rays, (2)

    International Nuclear Information System (INIS)

    Kanazawa, Tamotsu; Okabe, Shigeru; Fukuda, Kyue; Furuta, Junichiro; Fujino, Takahiro

    1981-01-01

    Mean ionization currents and pulse figures of parallel plate ionization chambers enclosed with various gases were measured when they were exposed to intense pulsed X-rays and continuous #betta#-rays. Relation between the measured ionization current and the intensity of X-rays was obtained at the applied voltage of 1000 V. In the case of intense pulsed X-rays, ionization current was smaller in comparison with the case of continuous #betta#-rays, under the X-rays of equal intensity. Pulse figures were observed with chambers which were filled with the gases of air and O 2 and they are considered to be caused by the free electrons of these gases. In these cases, polarity effects of the electric field on the pulse figures were not recognized. Various figures and their changes were also observed from chambers filled with He, Ne, N 2 , Ar, kr, and Xe, respectively. Polarity effects were recognized on those pulse figures. (author)

  20. Advanced intensity-modulation continuous-wave lidar techniques for ASCENDS CO2 column measurements

    Science.gov (United States)

    Campbell, Joel F.; Lin, Bing; Nehrir, Amin R.; Harrison, F. W.; Obland, Michael D.; Meadows, Byron

    2015-10-01

    Global atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity- Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space to meet the ASCENDS measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud contamination. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating the need to correct for sidelobe bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. A comparison of BPSK and linear swept-frequency is also discussed in this paper. These results are extended to include Richardson-Lucy deconvolution techniques to extend the resolution of the lidar beyond that implied by limit of the bandwidth of the modulation, where it is shown useful for making tree canopy measurements.

  1. Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for ASCENDS O2 Column Measurements

    Science.gov (United States)

    Campbell, Joel F.; Lin, Bing; Nehrir, Amin R.; Harrison, F. Wallace; Obland, Michael D.; Meadows, Byron

    2015-01-01

    Global atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity- Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space to meet the ASCENDS measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud contamination. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating the need to correct for sidelobe bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. A comparison of BPSK and linear swept-frequency is also discussed in this paper. These results are extended to include Richardson-Lucy deconvolution techniques to extend the resolution of the lidar beyond that implied by limit of the bandwidth of the modulation, where it is shown useful for making tree canopy measurements.

  2. L X-ray intensity ratio measurements using selective L sub-shell photo-ionisation on synchrotron

    Science.gov (United States)

    Bansal, Himani; Tiwari, M. K.; Mittal, Raj

    2017-10-01

    Lα/Lℓ, Lβ /Lℓ and Lγ/Lℓ intensity ratios have been measured for elements in the range 66≤Z≤83 at tuned photon energies on synchrotron beam line-16 at Indus-2, India. For each element, three incident energies Ei were E3; EL3 EL1 where ELi are Li absorption edge energies of the element. Emitted L X-ray spectrum of an element constitutes a number of X-ray lines generally grouped into four main groups due to limited resolution of available detectors as Lℓ(L3-M1), Lα(L3-M4,5), Lβ(L1-M2,3,4,5,N4; L2-M3,4; L3-N1,4,5,O1,4,5) and Lγ(L2-N1,4,O1,4; L1-N2,3,5,O3,2). Lα and Lℓ both comprise only the lines feeding L3 level and Lβ group comprises X-ray lines feeding all the three sub-shells where as Lγ involves contribution from L1 and L2 feedings. Only E3 excitation gives the ratios free from intra sub-shell Coster-Kronig (CK) transitions while excitations E2 and E1 give CK affected Lβ/Lℓ and Lγ/Lℓ X-ray intensity ratios and Lα/Lℓ still remains free from CKs. The pattern of intensity ratios at three excitation energies of elements was well interpreted in terms of on/off of CK transitions (Bambynek et al., 1972; Campbell, 2003) and outer shell electron filling configuration (Scofield, 1973).

  3. Open intensive care units: a global challenge for patients, relatives, and critical care teams.

    Science.gov (United States)

    Cappellini, Elena; Bambi, Stefano; Lucchini, Alberto; Milanesio, Erika

    2014-01-01

    The aims of this study were to describe the current status of intensive care unit (ICU) visiting hours policies internationally and to explore the influence of ICUs' open visiting policies on patients', visitors', and staff perceptions, as well as on patients' outcomes. A review of the literature was done through MEDLINE, EMBASE, and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases. The following keywords were searched: "visiting," "hours," "ICU," "policy," and "intensive care unit." Inclusion criteria for the review were original research paper, adult ICU, articles published in the last 10 years, English or Italian language, and available abstract. Twenty-nine original articles, mainly descriptive studies, were selected and retrieved. In international literature, there is a wide variability about open visiting policies in ICUs. The highest percentage of open ICUs is reported in Sweden (70%), whereas in Italy there is the lowest rate (1%). Visiting hours policies and number of allowed relatives are variable, from limits of short precise segments to 24 hours and usually 2 visitors. Open ICUs policy/guidelines acknowledge concerns with visitor hand washing to prevent the risk of infection transmission to patients. Patients, visitors, and staff seem to be inclined to support open ICU programs, although physicians are more inclined to the enhancement of visiting hours than nurses. The percentages of open ICUs are very different among countries. It can be due to local factors, cultural differences, and lack of legislation or hospital policy. There is a need for more studies about the impact of open ICUs programs on patients' mortality, length of stay, infections' risk, and the mental health of patients and their relatives.

  4. Mitigating cutaneous sensation differences during tDCS: comparing sham versus low intensity control conditions.

    Science.gov (United States)

    Brunyé, Tad T; Cantelon, Julie; Holmes, Amanda; Taylor, Holly A; Mahoney, Caroline R

    2014-01-01

    Cutaneous sensations at electrode sites during the administration of direct current brain stimulation may inadvertently influence participants' subjective experience and task performance. The present study evaluated the utility of a methodological variation that substitutes sham administration with very low intensity (0.5 mA) current delivery. We used a 4 × 1 high-definition ring electrode transcranial direct current (HD-tDCS) system to target the left dorsolateral prefrontal cortex (Brodmann's Area 9). Four stimulation conditions were compared in a repeated-measures design: sham 2.0 mA and 0.5 mA intensity, versus active 2.0 mA and 0.5 mA intensity. During stimulation participants performed a cognitive interference task that activates the cingulo-frontal-parietal network, and periodically provided perceived sensation ratings. We demonstrate that a relatively low intensity control condition attenuates otherwise large differences in perceived sensation between active and sham conditions. Critically, behavioral task differences maintained between the two active conditions. A low intensity control stimulation condition may prove a viable methodological alternative to conventional sham techniques used in repeated-measures designs, though important limitations are discussed. Published by Elsevier Inc.

  5. The consequences of shoulder pain intensity on quality of life and community participation in paraplegic wheelchair users

    Directory of Open Access Journals (Sweden)

    Nulle A.

    2012-10-01

    Full Text Available Background/Objective: Shoulder overuse due weight-bearing loads – wheelchair propulsion and transfers – are supposed to cause shoulder pain in active wheelchair users. Consequently, shoulder pain has been found to have a high prevalence in the spinal cord-injured population. Severity of pain levels in individuals with spinal cord injury has been shown to impact quality of life. Aim of this study was to describe the consequences of shoulder pain intensity on quality of life, physical activity, and community activities in spinal cord-injured paraplegic wheelchair users. Materials and Methods: It was a qualitative, analytical one moment study where was involved persons after spinal cord injury below Th1 with lower paraplegia, who used manually operated wheelchairs for mobility at least 50% of the time. Main outcomes measure: SF-36textregistered Health Survey, Physical Activity Scale for Individuals With Physical Disabilities, Community Activities Checklist, Wheelchair User’s Shoulder Pain Index, Functional Independence Measure, Goniometry for shoulder joint. Results and analysis: 40 participants (9 female, 31 male after spinal cord injury (SCI, mean age – 30,8 years, one to twenty years after spinal cord injury. 20 participants had pain in shoulder, 20 participants without pain in shoulder. The intensity of shoulder pain was not related to duration of SCI or the duration of shoulder pain. Shoulder pain intensity scores were inversely related to quality of life. There was a moderate, inverse relationship between shoulder pain intensity and physical activity. There was no relationship, however, between shoulder pain intensity and community activities. The level of community activity was positively related to quality of life. Conclusions: Persons with spinal cord injury who reported lower subjective quality of life and physical activity scores experienced significantly higher levels of shoulder pain. Shoulder pain intensity did not relate to

  6. The Relation between Frequency of E-Cigarette Use and Frequency and Intensity of Cigarette Smoking among South Korean Adolescents.

    Science.gov (United States)

    Lee, Jung Ah; Lee, Sungkyu; Cho, Hong-Jun

    2017-03-14

    The prevalence of adolescent electronic cigarette (e-cigarette) use has increased in most countries. This study aims to determine the relation between the frequency of e-cigarette use and the frequency and intensity of cigarette smoking. Additionally, the study evaluates the association between the reasons for e-cigarette use and the frequency of its use. Using the 2015 Korean Youth Risk Behavior Web-Based Survey, we included 6655 adolescents with an experience of e-cigarette use who were middle and high school students aged 13-18 years. We compared smoking experience, the frequency and intensity of cigarette smoking, and the relation between the reasons for e-cigarette uses and the frequency of e-cigarette use. The prevalence of e-cigarette ever and current (past 30 days) users were 10.1% and 3.9%, respectively. Of the ever users, approximately 60% used e-cigarettes not within 1 month. On the other hand, 8.1% used e-cigarettes daily. The frequent and intensive cigarette smoking was associated with frequent e-cigarette uses. The percentage of frequent e-cigarette users (≥10 days/month) was 3.5% in adolescents who did not smoke within a month, but 28.7% among daily smokers. Additionally, it was 9.1% in smokers who smoked less than 1 cigarette/month, but 55.1% in smokers who smoked ≥20 cigarettes/day. The most common reason for e-cigarette use was curiosity (22.9%), followed by the belief that they are less harmful than conventional cigarettes (18.9%), the desire to quit smoking (13.1%), and the capacity for indoor use (10.7%). Curiosity was the most common reason among less frequent e-cigarette users; however, the desire to quit smoking and the capacity for indoor use were the most common reasons among more frequent users. Results showed a positive relation between frequency or intensity of conventional cigarette smoking and the frequency of e-cigarette use among Korean adolescents, and frequency of e-cigarette use differed according to the reason for the use of

  7. Neurons in the inferior colliculus of the rat show stimulus-specific adaptation for frequency, but not for intensity

    Science.gov (United States)

    Duque, Daniel; Wang, Xin; Nieto-Diego, Javier; Krumbholz, Katrin; Malmierca, Manuel S.

    2016-01-01

    Electrophysiological and psychophysical responses to a low-intensity probe sound tend to be suppressed by a preceding high-intensity adaptor sound. Nevertheless, rare low-intensity deviant sounds presented among frequent high-intensity standard sounds in an intensity oddball paradigm can elicit an electroencephalographic mismatch negativity (MMN) response. This has been taken to suggest that the MMN is a correlate of true change or “deviance” detection. A key question is where in the ascending auditory pathway true deviance sensitivity first emerges. Here, we addressed this question by measuring low-intensity deviant responses from single units in the inferior colliculus (IC) of anesthetized rats. If the IC exhibits true deviance sensitivity to intensity, IC neurons should show enhanced responses to low-intensity deviant sounds presented among high-intensity standards. Contrary to this prediction, deviant responses were only enhanced when the standards and deviants differed in frequency. The results could be explained with a model assuming that IC neurons integrate over multiple frequency-tuned channels and that adaptation occurs within each channel independently. We used an adaptation paradigm with multiple repeated adaptors to measure the tuning widths of these adaption channels in relation to the neurons’ overall tuning widths. PMID:27066835

  8. Effect of Light Intensity on the Relative Dominance of Toxigenic and Nontoxigenic Strains of Microcystis aeruginosa ▿

    Science.gov (United States)

    LeBlanc Renaud, Susan; Pick, Frances R.; Fortin, Nathalie

    2011-01-01

    In aquatic ecosystems, the factors that regulate the dominance of toxin-producing cyanobacteria over non-toxin-producing strains of the same species are largely unknown. One possible hypothesis is that limiting resources lead to the dominance of the latter because of the metabolic costs associated with toxin production. In this study, we tested the effect of light intensity on the performance of a microcystin-producing strain of Microcystis aeruginosa (UTCC 300) when grown in mixed cultures with non-microcystin-producing strains with similar intrinsic growth rates (UTCC 632 and UTCC 633). The endpoints measured included culture growth rates, microcystin concentrations and composition, and mcyD gene copy numbers determined using quantitative PCR (Q-PCR). In contrast to the predicted results, under conditions of low light intensity (20 μmol·m−2·s−1), the toxigenic strain became dominant in both of the mixed cultures based on gene copy numbers and microcystin concentrations. When grown under conditions of high light intensity (80 μmol·m−2·s−1), the toxigenic strain still appeared to dominate over nontoxigenic strain UTCC 632 but less so over strain UTCC 633. Microcystins may not be so costly to produce that toxigenic cyanobacteria are at a disadvantage in competition for limiting resources. PMID:21841026

  9. Non-invasive treatment efficacy evaluation for high-intensity focused ultrasound therapy using magnetically induced magnetoacoustic measurement

    Science.gov (United States)

    Guo, Gepu; Wang, Jiawei; Ma, Qingyu; Tu, Juan; Zhang, Dong

    2018-04-01

    Although the application of high intensity focused ultrasound (HIFU) has been demonstrated to be a non-invasive treatment technology for tumor therapy, the real-time temperature monitoring is still a key issue in the practical application. Based on the temperature-impedance relation, a fixed-point magnetically induced magnetoacoustic measurement technology of treatment efficacy evaluation for tissue thermocoagulation during HIFU therapy is developed with a sensitive indicator of critical temperature monitoring in this study. With the acoustic excitation of a focused transducer in the magnetoacoustic tomography with the magnetic induction system, the distributions of acoustic pressure, temperature, electrical conductivity, and acoustic source strength in the focal region are simulated, and the treatment time dependences of the peak amplitude and the corresponding amplitude derivative under various acoustic powers are also achieved. It is proved that the strength peak of acoustic sources is generated by tissue thermocoagulation with a sharp conductivity variation. The peak amplitude of the transducer collected magnetoacoustic signal increases accordingly along with the increase in the treatment time under a fixed acoustic power. When the temperature in the range with the radial and axial widths of about ±0.46 mm and ±2.2 mm reaches 69 °C, an obvious peak of the amplitude derivative can be achieved and used as a sensitive indicator of the critical status of treatment efficacy. The favorable results prove the feasibility of real-time non-invasive temperature monitoring and treatment efficacy evaluation for HIFU ablation using the magnetically induced magnetoacoustic measurement, and might provide a new strategy for accurate dose control during HIFU therapy.

  10. ADOLESCENT WORK INTENSITY, SCHOOL PERFORMANCE, AND ACADEMIC ENGAGEMENT.

    Science.gov (United States)

    Staff, Jeremy; Schulenberg, John E; Bachman, Jerald G

    2010-07-01

    Teenagers working over 20 hours per week perform worse in school than youth who work less. There are two competing explanations for this association: (1) that paid work takes time and effort away from activities that promote achievement, such as completing homework, preparing for examinations, getting help from parents and teachers, and participating in extracurricular activities; and (2) that the relationship between paid work and school performance is spurious, reflecting preexisting differences between students in academic ability, motivation, and school commitment. Using longitudinal data from the ongoing national Monitoring the Future project, this research examines the impact of teenage employment on school performance and academic engagement during the 8th, 10th, and 12th grades. We address issues of spuriousness by using a two-level hierarchical model to estimate the relationships of within-individual changes in paid work to changes in school performance and other school-related measures. Unlike prior research, we also compare youth school performance and academic orientation when they are actually working in high-intensity jobs to when they are jobless and wish to work intensively. Results indicate that the mere wish for intensive work corresponds with academic difficulties in a manner similar to actual intensive work.

  11. Simultaneously Suppressing Low-Frequency and Relaxation Oscillation Intensity Noise in a DBR Single-Frequency Phosphate Fiber Laser

    International Nuclear Information System (INIS)

    Xiao Yu; Li Can; Xu Shan-Hui; Feng Zhou-Ming; Yang Chang-Sheng; Zhao Qi-Lai; Yang Zhong-Min

    2015-01-01

    Effective multiple optoelectronic feedback circuits for simultaneously suppressing low-frequency and relaxation oscillation intensity noise in a single-frequency phosphate fiber laser are demonstrated. The forward transfer function, which relates the laser output intensity to the pump modulations, is measured and analyzed. A custom two-path feedback system operating at different frequency bands is designed to adjust the pump current directly. The relative intensity noise is decreased by 20 dB from 0.2 to 5kHz and over 10 dB from 5 to 10 kHz. The relaxation oscillation peak is suppressed by 22 dB. In addition, a long term (24 h) laser instability of less than 0.05% is achieved. (paper)

  12. Line Intensity Measurements in 14N 216O and Their Treatment Using the Effective Dipole Moment Approach . I. The 4300- to 5200-cm -1 Region

    Science.gov (United States)

    Daumont, L.; Auwera, J. Vander; Teffo, J.-L.; Perevalov, V. I.; Tashkun, S. A.

    2001-08-01

    This work continues a series of publications devoted to the application of the effective operator approach to the vibrational-rotational treatment of linear triatomic molecules, aiming at the analysis and prediction of their infrared spectra. In that frame work, we have started a large-scale work aiming at the global description of line intensities of cold and hot bands of 14N216O in its ground electronic state in the spectral range above 3600 cm-1. In 14N216O, vibrational interacting levels group in polyads as a result of the relation 2ω1≈4ω2≈ω3 existing between the harmonic frequencies. The polyads are identified by the so-called polyad number P=2V1+V2+4V3. The work described in the present paper concerns bands associated with transitions corresponding to ΔP=7, 8, and 9. The absorption spectra of N2O at room temperature have been recorded at a resolution of 0.007 cm-1 in the range from 4300 to 5200 cm-1 using a Bruker IFS120HR Fourier transform spectrometer. Sample pressure/absorption path length products ranging from 7 to 1753 mbar × m have been used. More than 3000 absolute line intensities have been measured in 66 different bands belonging to the ΔP=7, 8, and 9 series. Dicke narrowing has been observed in the high-pressure spectra. Using wavefunctions previously determined from a global fit of an effective Hamiltonian to about 18,000 line positions (S. A. Tashkun, V. I. Perevalov, and J.-L. Teffo to be published), the experimental intensities measured in this work and by R. A. Toth (J. Mol. Spectrosc.197, 158-187 (1999)) were fitted to 47 parameters of a corresponding effective dipole moment, with residuals very close to the experimental uncertainty. Exa mples are given showing that the modeling reproduces intensities of perturbed lines well.

  13. The summertime Boreal forest field measurement intensive (HUMPPA-COPEC-2010): an overview of meteorological and chemical influences.

    Science.gov (United States)

    Williams, J.; Petäjä, T.

    2012-04-01

    This submission describes the background, instrumentation, goals, and the regional influences on the HUMPPA-COPEC intensive field measurement campaign, conducted at the Boreal forest research station SMEAR II (Station for Measuring Ecosystem-Atmosphere Relation) in Hyytiälä, Finland from 12th July-12th August 2010. The prevailing meteorological conditions during the campaign are examined and contrasted with those of the past six years. Back trajectory analyses show that meteorological conditions at the site in 2010 were characterized by a higher proportion of southerly flow than in the other years studied. As a result the summer of 2010 was anomalously warm and high in ozone making the campaign relevant for the analysis of possible future climates. A comprehensive land use analysis, provided on both 5 and 50 km scales, shows that the main vegetation types surrounding the site on both the regional and local scales are: coniferous forest (Scots pine and/or Norway spruce); mixed forest (Birch and conifers); and woodland scrub (e.g. Willows, Aspen); indicating that the campaign results can be taken as representative of the Boreal forest ecosystem. In addition to the influence of biogenic emissions, the measurement site was occasionally impacted by sources other than vegetation. Specific tracers have been used here to identify the time periods when such sources have impacted the site namely: biomass burning (acetonitrile and CO), urban anthropogenic pollution (pentane and SO2) and the nearby Korkeakoski sawmill (enantiomeric ratio of chiral monoterpenes). None of these sources dominated the study period, allowing the Boreal forest summertime emissions to be assessed and contrasted with various other source signatures.

  14. The summertime Boreal forest field measurement intensive (HUMPPA-COPEC-2010: an overview of meteorological and chemical influences

    Directory of Open Access Journals (Sweden)

    J. Williams

    2011-10-01

    Full Text Available This paper describes the background, instrumentation, goals, and the regional influences on the HUMPPA-COPEC intensive field measurement campaign, conducted at the Boreal forest research station SMEAR II (Station for Measuring Ecosystem-Atmosphere Relation in Hyytiälä, Finland from 12 July–12 August 2010. The prevailing meteorological conditions during the campaign are examined and contrasted with those of the past six years. Back trajectory analyses show that meteorological conditions at the site in 2010 were characterized by a higher proportion of southerly flow than in the other years studied. As a result the summer of 2010 was anomalously warm and high in ozone making the campaign relevant for the analysis of possible future climates. A comprehensive land use analysis, provided on both 5 and 50 km scales, shows that the main vegetation types surrounding the site on both the regional and local scales are: coniferous forest (Scots pine and/or Norway spruce; mixed forest (Birch and conifers; and woodland scrub (e.g. Willows, Aspen; indicating that the campaign results can be taken as representative of the Boreal forest ecosystem. In addition to the influence of biogenic emissions, the measurement site was occasionally impacted by sources other than vegetation. Specific tracers have been used here to identify the time periods when such sources have impacted the site namely: biomass burning (acetonitrile and CO, urban anthropogenic pollution (pentane and SO2 and the nearby Korkeakoski sawmill (enantiomeric ratio of chiral monoterpenes. None of these sources dominated the study period, allowing the Boreal forest summertime emissions to be assessed and contrasted with various other source signatures.

  15. Intensity Modulation Techniques for Continuous-Wave Lidar for Column CO2 Measurements

    Science.gov (United States)

    Campbell, J. F.; Lin, B.; Obland, M. D.; Kooi, S. A.; Fan, T. F.; Meadows, B.; Browell, E. V.; Erxleben, W. H.; McGregor, D.; Dobler, J. T.; Pal, S.; O'Dell, C.

    2017-12-01

    Global and regional atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission and the Atmospheric Carbon and Transport (ACT) - America project are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity-Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space and airborne platforms to meet the ASCENDS and ACT-America science measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) and Linear Swept Frequency modulations to uniquely discriminate surface lidar returns from intermediate aerosol and cloud returns. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that take advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques and provides very high (at sub-meter level) range resolution. We compare BPSK to linear swept frequency and introduce a new technique to eliminate sidelobes in situations from linear swept frequency where the SNR is high with results that rival BPSK. We also investigate the effects of non-linear modulators, which can in some circumstances degrade the orthogonality of the waveforms, and show how to avoid this. These techniques are used in a new data processing architecture written in

  16. Blood glucose control in the intensive care unit: benefits and risks.

    Science.gov (United States)

    Gunst, Jan; Van den Berghe, Greet

    2010-01-01

    Abnormal blood glucose levels are common during critical illness and are associated with outcomes that correspond to a J-shaped curve, the lowest risk associated with normoglycemia. Three proof-of-concept randomized-controlled-trials performed in the surgical, medical, and pediatric intensive care units of the Leuven University Hospital in Belgium demonstrated that maintaining strict age-adjusted normal fasting levels of glycemia (80-110 mg/dl in adults, 70-100 mg/dl in children, 50-80 mg/dl in infants) with intensive insulin therapy reduced morbidity and mortality as compared with tolerating stress hyperglycemia as a potentially beneficial response. Recently, concern has risen about the safety of this intervention, as a multicenter adult study reported an, as yet unexplained, increased mortality with targeting normoglycemia as compared with an intermediate blood glucose level of around 140 mg/dl. This apparent contradiction may be explained by several methodological differences among studies, comprising, among others, different glucose target ranges in the control groups, different feeding policies, and variable accuracy of tools used for glucose measurement and insulin infusion. Hence, efficacy and safety of intensive insulin therapy may be affected by patient-related and ICU setting-related variables. Therefore, no single optimal blood glucose target range for ICU patients can be advocated. It appears safe not to embark on targeting "age-normal" levels in intensive care units (ICUs) that are not equipped to accurately and frequently measure blood glucose, and have not acquired extensive experience with intravenous insulin administration using a customized guideline. A simple fallback position could be to control blood glucose levels as close to normal as possible without evoking unacceptable blood glucose fluctuations, hypoglycemia, and hypokalemia.

  17. Transport of intense ion beams

    International Nuclear Information System (INIS)

    Lambertson, G.; Laslett, L.J.; Smith, L.

    1977-01-01

    The possibility of using intense bursts of heavy ions to initiate an inertially confined fusion reaction has stimulated interest in the transport of intense unneutralized heavy ion beams by quadrupole or solenoid systems. This problem was examined in some detail, using numerical integration of the coupled envelope equations for the quadrupole case. The general relations which emerge are used to develop examples of high energy transport systems and as a basis for discussing the limitations imposed by a transport system on achievable intensities for initial acceleration

  18. Relationship Study on Land Use Spatial Distribution Structure and Energy-Related Carbon Emission Intensity in Different Land Use Types of Guangdong, China, 1996–2008

    Directory of Open Access Journals (Sweden)

    Yi Huang

    2013-01-01

    Full Text Available This study attempts to discuss the relationship between land use spatial distribution structure and energy-related carbon emission intensity in Guangdong during 1996–2008. We quantized the spatial distribution structure of five land use types including agricultural land, industrial land, residential and commercial land, traffic land, and other land through applying spatial Lorenz curve and Gini coefficient. Then the corresponding energy-related carbon emissions in each type of land were calculated in the study period. Through building the reasonable regression models, we found that the concentration degree of industrial land is negatively correlated with carbon emission intensity in the long term, whereas the concentration degree is positively correlated with carbon emission intensity in agricultural land, residential and commercial land, traffic land, and other land. The results also indicate that land use spatial distribution structure affects carbon emission intensity more intensively than energy efficiency and production efficiency do. These conclusions provide valuable reference to develop comprehensive policies for energy conservation and carbon emission reduction in a new perspective.

  19. A randomized comparison study regarding the impact of short-duration, high-intensity exercise and traditional exercise on anthropometric and body composition measurement changes in post-menopausal women--A pilot study.

    Science.gov (United States)

    Grossman, Joan A Cebrick; Payne, Ellen K

    2016-03-01

    The mode and duration of exercise necessary to change body composition and reduce weight remains debatable. Menopause results in hormonal changes that preclude weight loss. This randomized pilot study compared the effects of short-duration, high-intensity interval training and traditional exercise on anthropometric and body composition measurement changes in post-menopausal women. To compare the effects of short-duration, high-intensity interval training and traditional methods of exercise (walking) on anthropometric, body composition and body weight change over a 12-week period. Subjects (N = 18) were post-menopausal, sedentary female volunteers, randomly assigned into one of two exercise groups. Both groups exercised five out of seven days for 12 weeks. The resistance group (n = 8) (54.3 ± 7.3 years; BMI = 28.0 ± 2.1 kg/m(2); mean ± SD) exercised for 15.0 ± 3.5 min, which consisted of five different exercise routines including upper and lower extremity, a cardio segment, yoga and abdominal exercises. The walkers (n = 10) (56.6 ± 5.2 years; BMI = 29.2 ± 2.6 kg/m(2); mean ± SD) exercised for 40.0 ± 5.0 min at 65% of their age-predicted maximum heart rate. Relative (%) body fat was measured via DEXA scan, along with five anthropometric measurements, all of which were taken prior to and after 12 weeks. Independent sample t-tests were probed for differences, p ≤ 0.05. No statistically significant changes were determined between the groups for pre-and post-measurements. The outcomes of this study provide a foundation for future comparisons of short-duration high-intensity interval training exercise and traditional exercise, or walking, on anthropometric and body composition measurement changes in sedentary, overweight, post-menopausal females over a 12-week period. © The Author(s) 2016.

  20. Electronic diary assessment of pain-related fear, attention to pain, and pain intensity in chronic low back pain patients.

    NARCIS (Netherlands)

    Roelofs, J.; Peters, M.L.; Patijn, J.; Schouten, E.G.; Vlaeyen, J.W.

    2004-01-01

    The present study investigated the relationships between pain-related fear, attention to pain, and pain intensity in daily life in patients with chronic low back pain. An experience sampling methodology was used in which electronic diary data were collected by means of palmtop computers from 40

  1. Important questions asked by family members of intensive care unit patients.

    Science.gov (United States)

    Peigne, Vincent; Chaize, Marine; Falissard, Bruno; Kentish-Barnes, Nancy; Rusinova, Katerina; Megarbane, Bruno; Bele, Nicolas; Cariou, Alain; Fieux, Fabienne; Garrouste-Orgeas, Maite; Georges, Hugues; Jourdain, Merce; Kouatchet, Achille; Lautrette, Alexandre; Legriel, Stephane; Regnier, Bernard; Renault, Anne; Thirion, Marina; Timsit, Jean-Francois; Toledano, Dany; Chevret, Sylvie; Pochard, Frédéric; Schlemmer, Benoît; Azoulay, Elie

    2011-06-01

    Relatives often lack important information about intensive care unit patients. High-quality information is crucial to help relatives overcome the often considerable situational stress and to acquire the ability to participate in the decision-making process, most notably regarding the appropriate level of care. We aimed to develop a list of questions important for relatives of patients in the intensive care unit. This was a multicenter study. Questions asked by relatives of intensive care unit patients were collected from five different sources (literature, panel of 28 intensive care unit nurses and physicians, 1-wk survey of nurses and 1-wk survey of physicians in 14 intensive care units, and in-depth interviews with 14 families). After a qualitative analysis (framework approach and thematic analysis), questions were rated by 22 relatives and 14 intensive care unit physicians, and the ratings were analyzed using principal component analysis and hierarchical clustering. The five sources produced 2,135 questions. Removal of duplicates and redundancies left 443 questions, which were distributed among nine predefined domains using a framework approach ("diagnosis," "treatment," "prognosis," "comfort," "interaction," "communication," "family," "end of life," and "postintensive care unit management"). Thematic analysis in each domain led to the identification of 46 themes, which were reworded as 46 different questions. Ratings by relatives and physicians showed that 21 of these questions were particularly important for relatives of intensive care unit patients. This study increases knowledge about the informational needs of relatives of intensive care unit patients. This list of questions may prove valuable for both relatives and intensive care unit physicians as a tool for improving communication in the intensive care unit.

  2. Direct measurement of the signal intensity of diffusion-weighted magnetic resonance imaging for preoperative grading and treatment guidance for brain gliomas

    Directory of Open Access Journals (Sweden)

    Chih-Chun Wu

    2012-11-01

    Conclusion: The proposed method – direct measuring of tumor signal intensity of DWI on PACS monitors – is feasible for grading gliomas in clinical neuro-oncology imaging services and has a high level of reliability and reproducibility.

  3. Picosecond buildup and relaxation of intense stimulated emission in GaAs

    International Nuclear Information System (INIS)

    Ageeva, N. N.; Bronevoi, I. L.; Zabegaev, D. N.; Krivonosov, A. N.

    2013-01-01

    In support of the idea developed previously based on circumstantial evidence, we have found that stimulated emission emerges in GaAs and its intensity increases with a picosecond delay relative to the front of powerful picosecond optical pumping that produced a dense electron-hole plasma. The emission intensity relaxes with decreasing pumping with a characteristic time of ∼10 ps. We have derived the dependences of the delay time, the relaxation time, and the duration of the picosecond emission pulse on its photon energy. The estimates based on the fact that the relaxation of emission is determined by electron-hole plasma cooling correspond to the measured relaxation time.

  4. Overt and Relational Aggression Participant Role Behavior: Measurement and Relations With Sociometric Status and Depression.

    Science.gov (United States)

    Casper, Deborah M; Card, Noel A; Bauman, Sheri; Toomey, Russell B

    2017-09-01

    This study is the first to measure participant role behavior across overt and relational forms of aggression. The Overt and Relational Aggression Participant Role Behavior Scales were designed to measure aggression, assisting, reinforcing, defending, victimization, and outsider behavior during acts of peer aggression in an ethnically diverse sample of 609 adolescents (M age = 12 years). The data fit the hypothesized 12-factor model, and measurement invariance was established across gender. Relational victimization, but not overt victimization, was positively associated with all other relational aggression roles. Each participant role subscale was positively associated with depressive symptoms with the exception of the overt and relational outsider subscales. Future research and intervention efforts should consider overt and relational aggression participant roles, separately. © 2017 The Authors. Journal of Research on Adolescence © 2017 Society for Research on Adolescence.

  5. High-intensity exercise interventions in cancer survivors: a systematic review exploring the impact on health outcomes.

    Science.gov (United States)

    Toohey, Kellie; Pumpa, Kate; McKune, Andrew; Cooke, Julie; Semple, Stuart

    2018-01-01

    There is an increasing body of evidence underpinning high-intensity exercise as an effective and time-efficient intervention for improving health in cancer survivors. The aim of this study was to, (1) evaluate the efficacy and (2) the safety of high-intensity exercise interventions in improving selected health outcomes in cancer survivors. Design Systematic review. Data sources Google Scholar and EBSCO, CINAHL Plus, Computers and Applied Sciences Complete, Health Source-Consumer Edition, Health Source: Nursing/Academic Edition, MEDLINE, Web of Science and SPORTDiscuss from inception up until August 2017. Eligibility criteria Randomized controlled trials of high-intensity exercise interventions in cancer survivors (all cancer types) with health-related outcome measures. The guidelines adopted for this review were the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). The search returned 447 articles, of which nine articles (n = 531 participants mean, age 58 ± 9.5 years) met the eligibility criteria. Exercise interventions of between 4 and 18 weeks consisting of high-intensity interval bouts of up to 4-min were compared with a continuous moderate intensity (CMIT) intervention or a control group. High-intensity exercise interventions elicited significant improvements in VO 2 max, strength, body mass, body fat and hip and waist circumference compared with CMIT and/or control groups. The studies reviewed showed low risk in participating in supervised high-intensity exercise interventions. Mixed mode high-intensity interventions which included both aerobic and resistance exercises were most effective improving the aerobic fitness levels of cancer survivors by 12.45-21.35%, from baseline to post-intervention. High-intensity exercise interventions improved physical and physiological health-related outcome measures such as cardiovascular fitness and strength in cancer survivors. Given that high-intensity exercise sessions require a

  6. On output measurements via radiation pressure

    DEFF Research Database (Denmark)

    Leeman, S.; Healey, A.J.; Forsberg, F.

    1990-01-01

    It is shown, by simple physical argument, that measurements of intensity with a radiation pressure balance should not agree with those based on calorimetric techniques. The conclusion is ultimately a consequence of the circumstance that radiation pressure measurements relate to wave momentum, while...... calorimetric methods relate to wave energy. Measurements with some typical ultrasound fields are performed with a novel type of hydrophone, and these allow an estimate to be made of the magnitude of the discrepancy to be expected between the two types of output measurement in a typical case....

  7. Focused ultrasound transducer spatial peak intensity estimation: a comparison of methods

    Science.gov (United States)

    Civale, John; Rivens, Ian; Shaw, Adam; ter Haar, Gail

    2018-03-01

    Characterisation of the spatial peak intensity at the focus of high intensity focused ultrasound transducers is difficult because of the risk of damage to hydrophone sensors at the high focal pressures generated. Hill et al (1994 Ultrasound Med. Biol. 20 259-69) provided a simple equation for estimating spatial-peak intensity for solid spherical bowl transducers using measured acoustic power and focal beamwidth. This paper demonstrates theoretically and experimentally that this expression is only strictly valid for spherical bowl transducers without a central (imaging) aperture. A hole in the centre of the transducer results in over-estimation of the peak intensity. Improved strategies for determining focal peak intensity from a measurement of total acoustic power are proposed. Four methods are compared: (i) a solid spherical bowl approximation (after Hill et al 1994 Ultrasound Med. Biol. 20 259-69), (ii) a numerical method derived from theory, (iii) a method using measured sidelobe to focal peak pressure ratio, and (iv) a method for measuring the focal power fraction (FPF) experimentally. Spatial-peak intensities were estimated for 8 transducers at three drive powers levels: low (approximately 1 W), moderate (~10 W) and high (20-70 W). The calculated intensities were compared with those derived from focal peak pressure measurements made using a calibrated hydrophone. The FPF measurement method was found to provide focal peak intensity estimates that agreed most closely (within 15%) with the hydrophone measurements, followed by the pressure ratio method (within 20%). The numerical method was found to consistently over-estimate focal peak intensity (+40% on average), however, for transducers with a central hole it was more accurate than using the solid bowl assumption (+70% over-estimation). In conclusion, the ability to make use of an automated beam plotting system, and a hydrophone with good spatial resolution, greatly facilitates characterisation of the FPF, and

  8. Coherence and entanglement measures based on Rényi relative entropies

    International Nuclear Information System (INIS)

    Zhu, Huangjun; Hayashi, Masahito; Chen, Lin

    2017-01-01

    We study systematically resource measures of coherence and entanglement based on Rényi relative entropies, which include the logarithmic robustness of coherence, geometric coherence, and conventional relative entropy of coherence together with their entanglement analogues. First, we show that each Rényi relative entropy of coherence is equal to the corresponding Rényi relative entropy of entanglement for any maximally correlated state. By virtue of this observation, we establish a simple operational connection between entanglement measures and coherence measures based on Rényi relative entropies. We then prove that all these coherence measures, including the logarithmic robustness of coherence, are additive. Accordingly, all these entanglement measures are additive for maximally correlated states. In addition, we derive analytical formulas for Rényi relative entropies of entanglement of maximally correlated states and bipartite pure states, which reproduce a number of classic results on the relative entropy of entanglement and logarithmic robustness of entanglement in a unified framework. Several nontrivial bounds for Rényi relative entropies of coherence (entanglement) are further derived, which improve over results known previously. Moreover, we determine all states whose relative entropy of coherence is equal to the logarithmic robustness of coherence. As an application, we provide an upper bound for the exact coherence distillation rate, which is saturated for pure states. (paper)

  9. 20 CFR 652.208 - How are core services and intensive services related to the methods of service delivery described...

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false How are core services and intensive services related to the methods of service delivery described in § 652.207(b)(2)? 652.208 Section 652.208 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR ESTABLISHMENT AND...

  10. Cryogenic semiconductor high-intensity radiation monitors

    International Nuclear Information System (INIS)

    Palmieri, V.G.; Bell, W.H.; Borer, K.; Casagrande, L.; Da Via, C.; Devine, S.R.H.; Dezillie, B.; Esposito, A.; Granata, V.; Hauler, F.; Jungermann, L.; Li, Z.; Lourenco, C.; Niinikoski, T.O.; Shea, V. O'; Ruggiero, G.; Sonderegger, P.

    2003-01-01

    This paper describes a novel technique to monitor high-intensity particle beams by means of a semiconductor detector. It consists of cooling a semiconductor detector down to cryogenic temperature to suppress the thermally generated leakage current and to precisely measure the integrated ionization signal. It will be shown that such a device provides very good linearity and a dynamic range wider than is possible with existing techniques. Moreover, thanks to the Lazarus effect, extreme radiation hardness can be achieved providing in turn absolute intensity measurements against precise calibration of the device at low beam flux

  11. Age-related changes in physical and perceptual markers of recovery following high-intensity interval cycle exercise.

    Science.gov (United States)

    Borges, Nattai R; Reaburn, Peter R; Doering, Thomas M; Argus, Christos K; Driller, Matthew W

    2018-05-29

    The purpose of this study was to compare physical performance, perceptual and haematological markers of recovery in well-trained masters and young cyclists across 48 h following a bout of repeated high-intensity interval exercise. Nine masters (mean ± SD; age = 55.6 ± 5.0 years) and eight young (age = 25.9 ± 3.0 years) cyclists performed a high-intensity interval exercise session consisting of 6 × 30 s intervals at 175% peak power output with 4.5 min rest between efforts. Maximal voluntary contraction (MVC), 10 s sprint (10SST), 30-min time trial (30TT) performance, creatine kinase concentration (CK) and perceptual measures of motivation, total recovery, fatigue and muscle soreness were collected at baseline and at standardised time points across the 48 h recovery period. No significant group-time interactions were observed for performance of MVC, 10SST, 30TT and CK (P > 0.05). A significant reduction in 10SST peak power was found in both masters (P = 0.002) and young (P = 0.003) cyclists at 1 h post exercise, however, both groups physically recovered at similar rates. Neither group showed significant (P > 0.05) or practically meaningful increases in CK (%∆ < 10%). A significant age-related difference was found for perceptual fatigue (P = 0.01) and analysis of effect size (ES) showed that perceptual recovery was delayed with masters cyclists reporting lower motivation (ES ±90%CI = 0.69 ± 0.77, moderate), greater fatigue (ES = 0.75 ± 0.93, moderate) and muscle soreness (ES = 0.61 ± 0.70, moderate) after 48 h of recovery. The delay in perceived recovery may have negative effects on long-term participation to systematic training.

  12. Exercise intensity of cycle-touring events.

    Science.gov (United States)

    Neumayr, G; Pfister, R; Mitterbauer, G; Gaenzer, H; Sturm, W; Eibl, G; Hoertnagl, H

    2002-10-01

    The aim of the study was to analyze the exercise intensity of recreational cyclists participating in a cycling-touring event. In 14 male healthy recreational cyclists heart rate (HR) monitoring was performed during the Otztal Radmarathon 1999 (distance: 230 km; altitude difference: 5500 m) in order to evaluate the HR response and to estimate the cardiopulmonary strains for the less-trained athlete confronted with such a marathon. Four different exercise intensities were defined as percentages of maximal HR (HR(max)) as follows: recovery HR (HR(re)) 90 %. All athletes finished the competition successfully. The mean racing time was 10 h 14 min, the average speed 22.5 km/h. The mean HR(max) was 188 bpm, the average value of the measured HRs (HR(average)) was 145 bpm resulting in a mean HR(average)/HR(max) ratio of 0.77. Athletes spent 18.5 % (1 h 54 min) of total race time within HR(re), 28 % (2 h 52 min) within HR(ma), 39.5 % (4 h 02 min) within HR(ia), and 14 % (1 h 26 min) within HR(an). The vast majority of exercise was done under "aerobic conditions" (HR(re) + HR(ma) + HR(ia) = 86 % or 8 h 48 min) - confirming the knowledge that the aerobic energy supply is crucial for the performance of long-term exercise. The large amount of high exercise intensities (HR(ia) + HR(an) = 53.5 % or 5 h 30 min), however, features the intense cardiopulmonary strains evoked by such competitions. The HR response was related to the course profile with HRs significantly declining in all subjects to an extent of 10 % during the course of race. Our findings show that the exercise intensity borne by recreational cyclists during a cycle-touring event is high and very similar to that of professionals. With respect to the high cardiovascular strains a thorough medical screening is advisable for any participant of such an event combining both high volume and high intensity loads.

  13. Plasma Temperature Determination of Hydrogen Containing High-Frequency Electrode less Lamps by Intensity Distribution Measurements of Hydrogen Molecular Band

    International Nuclear Information System (INIS)

    Gavare, Z.; Revalde, G.; Skudra, A.

    2011-01-01

    The goal of the present work was the investigation of the possibility to use intensity distribution of the Q-branch lines of the hydrogen Fulcher-a diagonal band (d3η u- a3Σg + electronic transition; Q-branch with ν=ν=2) to determine the temperature of hydrogen containing high-frequency electrode less lamps (HFEDLs). The values of the rotational temperatures have been obtained from the relative intensity distributions for hydrogen-helium and hydrogen-argon HFEDLs depending on the applied current. The results have been compared with the method of temperature derivation from Doppler profiles of He 667.8 nm and Ar 772.4 nm lines. The results of both methods are in good agreement, showing that the method of gas temperature determination from the intensity distribution in the hydrogen Fulcher-a (2-2)Q band can be used for the hydrogen containing HFEDLs. It was observed that the admixture of 10% hydrogen in the argon HFEDLs significantly reduces the gas temperature

  14. Reduced-intensity conditioning lowers treatment-related mortality of allogeneic stem cell transplantation for chronic lymphocytic leukemia : a population-matched analysis

    NARCIS (Netherlands)

    Dreger, P; Brand, R; Milligan, D; Corradini, P; Finke, J; Deliliers, GL; Martino, R; Russell, N; van Biezen, A; Michallet, M; Niederwieser, D

    To elucidate whether reduced-intensity conditioning (RIC) decreases treatment-related mortality (TRM) after allogeneic stem cell transplantation (allo-SCT) for chronic lymphocytic leukemia (CLL), we retrospectively compared 73 RIC cases from a recent EBMT survey with 82 patients from the EBMT

  15. Neutron measurement techniques for tokamak plasmas

    International Nuclear Information System (INIS)

    Jarvis, O.N.

    1994-01-01

    The present article reviews the neutron measurement techniques that are currently being applied to the study of tokamak plasmas. The range of neutron energies of primary interest is limited to narrow bands around 2.5 and 14 MeV, and the variety of measurements that can be made for plasma diagnostic purposes is also restricted. To characterize the plasma as a neutron source, it is necessary only to measure the total neutron emission, the relative neutron emissivity as a function of position throughout the plasma, and the energy spectra of the emitted neutrons. In principle, such measurements might be expected to be relatively easy. That this is not the case is, in part, attributable to practical problems of accessibility to a harsh environment but is mostly a consequence of the time-scale on which the measurements have to be made and of the wide range of neutron emission intensities that have to be covered: for tokamak studies, the time-scale is of the order of 1 to 100 ms and the neutron intensity ranges from 10 12 to 10 19 s -1 . (author)

  16. Macroseismic intensity attenuation in Iran

    Science.gov (United States)

    Yaghmaei-Sabegh, Saman

    2018-01-01

    Macroseismic intensity data plays an important role in the process of seismic hazard analysis as well in developing of reliable earthquake loss models. This paper presents a physical-based model to predict macroseismic intensity attenuation based on 560 intensity data obtained in Iran in the time period 1975-2013. The geometric spreading and energy absorption of seismic waves have been considered in the proposed model. The proposed easy to implement relation describes the intensity simply as a function of moment magnitude, source to site distance and focal depth. The prediction capability of the proposed model is assessed by means of residuals analysis. Prediction results have been compared with those of other intensity prediction models for Italy, Turkey, Iran and central Asia. The results indicate the higher attenuation rate for the study area in distances less than 70km.

  17. A 40 MHz Bunch by Bunch Intensity Measurement for the CERN SPS and LHC

    CERN Document Server

    Jakob, H; Jones, R; Jensen, L

    2003-01-01

    A new acquisition system has been developed to allow the measurement of the individual intensity of each bunch in a 40MHz bunch train. Such a system will be used for the measurement of LHC type beams after extraction from the CERN-PS right through to the dump lines of the CERN-LHC. The method is based on integrating the analogue signal supplied by a Fast Beam Current Transformer at a frequency of 40MHz. This has been made possible with the use of a fast integration ASIC developed by the University of Clermont-Ferrand, France, for the LHC-b pre-shower detector. The output of the integrator is digitised using a 12-bit ADC and fed into a Digital Acquisition Board (DAB) that was originally developed by TRIUMF, Canada, for use in the LHC orbit system. A full system set-up was commissioned during 2002 in the CERN-SPS, and following its success will now be extended in 2003 to cover the PS to SPS transfer lines and the new TT40 LHC extraction channel.

  18. Investigating Efficiency of Vector-Valued Intensity Measures in Seismic Demand Assessment of Concrete Dams

    Directory of Open Access Journals (Sweden)

    Mohammad Alembagheri

    2018-01-01

    Full Text Available The efficiency of vector-valued intensity measures for predicting the seismic demand in gravity dams is investigated. The Folsom gravity dam-reservoir coupled system is selected and numerically analyzed under a set of two-hundred actual ground motions. First, the well-defined scalar IMs are separately investigated, and then they are coupled to form two-parameter vector IMs. After that, IMs consisting of spectral acceleration at the first-mode natural period of the dam-reservoir system along with a measure of the spectral shape (the ratio of spectral acceleration at a second period to the first-mode spectral acceleration value are considered. It is attempted to determine the optimal second period by categorizing the spectral acceleration at the first-mode period of vibration. The efficiency of the proposed vector IMs is compared with scalar ones considering various structural responses as EDPs. Finally, the probabilistic seismic behavior of the dam is investigated by calculating its fragility curves employing scalar and vector IMs considering the effect of zero response values.

  19. Low-intensity daily walking activity is associated with hippocampal volume in older adults.

    Science.gov (United States)

    Varma, Vijay R; Chuang, Yi-Fang; Harris, Gregory C; Tan, Erwin J; Carlson, Michelle C

    2015-05-01

    Hippocampal atrophy is associated with memory impairment and dementia and serves as a key biomarker in the preclinical stages of Alzheimer's disease. Physical activity, one of the most promising behavioral interventions to prevent or delay cognitive decline, has been shown to be associated with hippocampal volume; specifically increased aerobic activity and fitness may have a positive effect on the size of the hippocampus. The majority of older adults, however, are sedentary and have difficulty initiating and maintaining exercise programs. A modestly more active lifestyle may nonetheless be beneficial. This study explored whether greater objectively measured daily walking activity was associated with larger hippocampal volume. We additionally explored whether greater low-intensity walking activity, which may be related to leisure-time physical, functional, and social activities, was associated with larger hippocampal volume independent of exercise and higher-intensity walking activity. Segmentation of hippocampal volumes was performed using Functional Magnetic Resonance Imaging of the Brain's Software Library (FSL), and daily walking activity was assessed using a step activity monitor on 92, nondemented, older adult participants. After controlling for age, education, body mass index, cardiovascular disease risk factors, and the Mini Mental State Exam, we found that a greater amount, duration, and frequency of total daily walking activity were each associated with larger hippocampal volume among older women, but not among men. These relationships were specific to hippocampal volume, compared with the thalamus, used as a control brain region, and remained significant for low-intensity walking activity, independent of moderate- to vigorous-intensity activity and self-reported exercise. This is the first study, to our knowledge, to explore the relationship between objectively measured daily walking activity and hippocampal volume in an older adult population. Findings

  20. Estimation of gadolinium-induced T1-shortening with measurement of simple signal intensity ratio between the cochlea and brain parenchyma on 3D-FLAIR. Correlation with T1 measurement by TI scout sequence

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Ishihara, Shunichi; Iwano, Shingo; Kawai, Hisashi; Sone, Michihiko; Nakashima, Tsutomu

    2010-01-01

    The purpose of this study was to T 1 -shortening of labyrinthine fluid on 3-dimensional fluid-attenuated inversion recovery (3D-FLAIR) has been reported in many inner ear disorders. Although semi-quantitative assessment by simple signal intensity ratio between cochlear fluid and brain tissue has been tried, its feasibility using a multi-channel phased-array head coil with an inherently inhomogenous sensitivity distribution has not been fully evaluated. We evaluated the feasibility of measuring simple signal intensity ratio by correlating rapid T 1 measurements using an inversion time (TI) scout sequence. We evaluated 10 patients with Meniere's disease and 4 patients with sudden deafness. Nine of the patients with Meniere's disease received a unilateral intratympanic injection of gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA); the tenth patient received bilateral injections. The 4 patients with sudden deafness received a double-dose intravenous injection. Magnetic resonance (MR) images were obtained 24 hours after intratympanic injections and 4 hours after intravenous injections at 3 tesla using a 32-channel head coil. We measured the ratio (CM ratio) between the signal intensity of the perilymph in the cochlea (C) and that of the medulla oblongata (M) and correlated it with the null-point inversion time (TI null ) obtained with the TI scout sequence. The TI scout consisted of 85 images obtained with TI values between 132.5 and 3087.5 ms at increments of 37.5 ms. The correlation coefficient between TI null and the natural logarithm of the CM ratio was -0.88 (P<0.01). There was significant negative linear correlation. Measurement of the simple signal intensity ratio between the cochlea and the medulla can be used for semi-quantitative analysis of 3D-FLAIR. The results of this study may facilitate clinical research of inner-ear disease using 3D-FLAIR. (author)