WorldWideScience

Sample records for measured peak ceiling

  1. Peak and ceiling effects in final-product analysis of mastoidectomy performance

    DEFF Research Database (Denmark)

    West, N; Konge, L; Cayé-Thomasen, P

    2015-01-01

    BACKGROUND: Virtual reality surgical simulation of mastoidectomy is a promising training tool for novices. Final-product analysis for assessing novice mastoidectomy performance could be limited by a peak or ceiling effect. These may be countered by simulator-integrated tutoring. METHODS: Twenty......-two participants completed a single session of self-directed practice of the mastoidectomy procedure in a virtual reality simulator. Participants were randomised for additional simulator-integrated tutoring. Performances were assessed at 10-minute intervals using final-product analysis. RESULTS: In all, 45.5 per...

  2. Measuring perceived ceiling height in a visual comparison task.

    Science.gov (United States)

    von Castell, Christoph; Hecht, Heiko; Oberfeld, Daniel

    2017-03-01

    When judging interior space, a dark ceiling is judged to be lower than a light ceiling. The method of metric judgments (e.g., on a centimetre scale) that has typically been used in such tasks may reflect a genuine perceptual effect or it may reflect a cognitively mediated impression. We employed a height-matching method in which perceived ceiling height had to be matched with an adjustable pillar, thus obtaining psychometric functions that allowed for an estimation of the point of subjective equality (PSE) and the difference limen (DL). The height-matching method developed in this paper allows for a direct visual match and does not require metric judgment. It has the added advantage of providing superior precision. Experiment 1 used ceiling heights between 2.90 m and 3.00 m. The PSE proved sensitive to slight changes in perceived ceiling height. The DL was about 3% of the physical ceiling height. Experiment 2 found similar results for lower (2.30 m to 2.50 m) and higher (3.30 m to 3.50 m) ceilings. In Experiment 3, we additionally varied ceiling lightness (light grey vs. dark grey). The height matches showed that the light ceiling appeared significantly higher than the darker ceiling. We therefore attribute the influence of ceiling lightness on perceived ceiling height to a direct perceptual rather than a cognitive effect.

  3. Ultrasonic Transducer Peak-to-Peak Optical Measurement

    Directory of Open Access Journals (Sweden)

    Pavel Skarvada

    2012-01-01

    Full Text Available Possible optical setups for measurement of the peak-to-peak value of an ultrasonic transducer are described in this work. The Michelson interferometer with the calibrated nanopositioner in reference path and laser Doppler vibrometer were used for the basic measurement of vibration displacement. Langevin type of ultrasonic transducer is used for the purposes of Electro-Ultrasonic Nonlinear Spectroscopy (EUNS. Parameters of produced mechanical vibration have to been well known for EUNS. Moreover, a monitoring of mechanical vibration frequency shift with a mass load and sample-transducer coupling is important for EUNS measurement.

  4. Effect of façade systems on the performance of cooling ceilings: In situ measurements

    Directory of Open Access Journals (Sweden)

    Katharina Eder

    2015-03-01

    Full Text Available This article presents an innovative façade system designed to increase the thermal comfort inside an office room and to enhance the cooling capacity of the suspended cooling ceiling. A series of measurements is conducted in an existing office building with different façade systems (i.e., a combination of glazing and shading. An innovative façade system is developed based on this intensive set of measurements. The new system enhances the thermal comfort and cooling capacity of the suspended cooling ceiling. The main usage of the new system is the refurbishment and improvement of existing façade systems.

  5. Measurements on Buoyant Jet Flows from a Ceiling-Mounted Slot Diffuser

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Möller, Åke T. A.

    Ceiling-mounted slot diffusers in ventilated rooms will often generate a flow of the wall jet type. The jet follows the ceiling, entrains air from the occupied zone and generates a recirculating flow in the whole room. This paper will deal with the flow in the ceiling region. The wall jet flow...

  6. Some practical aspects of peak kilovoltage measurements

    International Nuclear Information System (INIS)

    Irfan, A.Y.; Pugh, V.I.; Jeffery, C.D.

    1985-01-01

    The peak kilovoltage (kVsub(p)) across the X-ray tube electrodes in diagnostic X-ray machines is a most important parameter, affecting both radiation output and beam quality. Four commercially available non-invasive devices used for kVsub(p) measurement were tested using a selection of generator waveforms. The majority of the devices provided satisfactory measurements of the kVsub(p) to within approximately +- kV provided certain operating conditions are observed. (U.K.)

  7. 10 CFR Appendix U to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Ceiling Fans

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Ceiling Fans 1. Scope... significant digits as the previous step. Round the final energy consumption value to the nearest whole number...

  8. Suspended ceilings

    Energy Technology Data Exchange (ETDEWEB)

    Talamo, C.

    1991-05-01

    The retrofitting of existing conventional ceiling systems to suspended ceiling type systems represents an interesting energy savings solution since this method, in addition to providing additional protection against space heat loss and thermal bridges, also creates the possibility of housing, in the void, additional mechanical and electrical lines which may be necessary due to other savings interventions. This paper reviews the various suspended ceiling systems (e.g., those making use of mineral fibre, gypsum panels, wood, vermiculite, etc.) currently marketed in Europe, and reports, for each, some key technical, economic and architectural advantages which include thermal efficiency, noise abatement, as well as, resistance to fire and humidity. Information is also given on the relative installation and maintenance requirements.

  9. Field measurements of moisture variation in cold ventilated attics with different ceiling constructions

    DEFF Research Database (Denmark)

    Hansen, Thor; Møller, Eva B.

    2017-01-01

    Adding insulation material on ceilings against cold ventilated attics is one of the most straightforward tasks of adding insulation. Theoretically, a higher amount of insulation in the attic decreases the temperature and consequently the capability of removing infiltrated indoor humid air. Field...

  10. Online junction temperature measurement using peak gate current

    DEFF Research Database (Denmark)

    Baker, Nick; Munk-Nielsen, Stig; Iannuzzo, Francesco

    2015-01-01

    A new method for junction temperature measurement of MOS-gated power semiconductor switches is presented. The measurement method involves detecting the peak voltage over the external gate resistor of an IGBT or MOSFET during turn-on. This voltage is directly proportional to the peak gate current...

  11. Effects of equipment and technique on peak flow measurements

    Directory of Open Access Journals (Sweden)

    O'Driscoll B Ronan

    2006-06-01

    Full Text Available Abstract Background Different lung function equipment and different respiratory manoeuvres may produce different Peak Expiratory Flow (PEF results. Although the PEF is the most common lung function test, there have been few studies of these effects and no previous study has evaluated both factors in a single group of patients. Methods We studied 36 subjects (PEF range 80–570 l/min. All patients recorded PEF measurements using a short rapid expiration following maximal inspiration (PEF technique or a forced maximal expiration to residual volume (FVC technique. Measurements were made using a Wright's peak flow meter, a turbine spirometer and a Fleisch pneumotachograph spirometer. Results The mean PEF was 8.7% higher when the PEF technique was used (compared with FVC technique, p Conclusion Peak flow measurements are affected by the instruction given and by the device and Peak Flow scale used. Patient management decisions should not be based on PEF measurement made on different instruments.

  12. Converter for Measurement of non-sinusoidal current peak value

    DEFF Research Database (Denmark)

    Butvin, P.; Nielsen, Otto V; Brauer, Peter

    1997-01-01

    A linear-response toroid with core wound of rapidly quenched soft magnetic metallic ribbon and fitted with two windings is used to enable correct measurement of mean peak value of non-sinusoidal and not noise-free alternating current.......A linear-response toroid with core wound of rapidly quenched soft magnetic metallic ribbon and fitted with two windings is used to enable correct measurement of mean peak value of non-sinusoidal and not noise-free alternating current....

  13. 10 CFR Appendix V to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Ceiling Fan Light Kits

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Appendix V to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Ceiling Fan... the final energy consumption value to a whole number as follows: (i) A fractional number at or above...

  14. Accuracy of portable devices in measuring peak cough flow

    International Nuclear Information System (INIS)

    Kulnik, Stefan Tino; Kalra, Lalit; MacBean, Victoria; Birring, Surinder Singh; Moxham, John; Rafferty, Gerrard Francis

    2015-01-01

    Peak cough flow (PCF) measurements can be used as indicators of cough effectiveness. Portable peak flow meters and spirometers have been used to measure PCF, but little is known about their accuracy compared to pneumotachograph systems. The aim of this study was to compare the accuracy of four portable devices (Mini–Wright and Assess peak flow meters, SpiroUSB and Microlab spirometers) in measuring PCF with a calibrated laboratory based pneumotachograph system. Twenty healthy volunteers (mean (SD) age 45 (16) years) coughed through a pneumotachograph connected in series with each portable device in turn, and the differences in PCF readings were analysed. In addition, mechanically generated flow waves of constant peak flow were delivered through each device both independently and when connected in series with the pneumotachograph. Agreement between PCF readings obtained with the pneumotachograph and the portable devices was poor. Peak flow readings were on average lower by approximately 50 L min −1 when measured using the portable devices; 95% limits of agreement spanned approximately 150 L min −1 . The findings highlight the potential for inaccuracy when using portable devices for the measurement of PCF. Depending on the measurement instrument used, absolute values of PCF reported in the literature may not be directly comparable. (paper)

  15. Measurement of peak discharge at dams by indirect methods

    Science.gov (United States)

    Hulsing, Harry

    1967-01-01

    This chapter describes procedures for measuring peak discharges using dams, weirs, and embankments. Field and office procedures limited to this method are described. Discharge coefficients and formulas are given for three general classes of weirs-sharp-crested, broad-crested, and round-crested-and for highway embankments and weirs of unusual shape. The effects of submergence are defined for most forms.

  16. Diffuse ceiling ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen

    Diffuse ceiling ventilation is an innovative ventilation concept where the suspended ceiling serves as air diffuser to supply fresh air into the room. Compared with conventional ventilation systems, diffuse ceiling ventilation can significantly reduce or even eliminate draught risk due to the low...

  17. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per; Nielsen, Peter V.

    2014-01-01

    As a novel air distribution system, diffuse ceiling ventilation combines the suspended acoustic ceiling with ventilation supply. Due to the low-impulse supply from the large ceiling area, the system does not generate draught when supplying cold air. However, heat sources play an important role...

  18. Detection of Golden apples' climacteric peak by laser biospeckle measurements.

    Science.gov (United States)

    Nassif, Rana; Nader, Christelle Abou; Afif, Charbel; Pellen, Fabrice; Le Brun, Guy; Le Jeune, Bernard; Abboud, Marie

    2014-12-10

    In this paper, we report a study in which a laser biospeckle technique is used to detect the climacteric peak indicating the optimal ripeness of fruits. We monitor two batches of harvested Golden apples going through the ripening phase in low- and room-temperature environments, determine speckle parameters, and measure the emitted ethylene concentration using gas chromatography as reference method. Speckle results are then correlated to the emitted ethylene concentration by a principal component analysis. From a practical point of view, this approach allows us to validate biospeckle as a noninvasive and alternative method to respiration rate and ethylene production for climacteric peak detection as a ripening index.

  19. Multiple Glass Ceilings

    OpenAIRE

    Russo, Giovanni; Hassink, Wolter

    2011-01-01

    Both vertical (between job levels) and horizontal (within job levels) mobility can be sources of wage growth. We find that the glass ceiling operates at both margins. The unexplained part of the wage gap grows across job levels (glass ceiling at the vertical margin) and across the deciles of the intra-job-level wage distribution (glass ceiling at the horizontal margin). This implies that women face many glass ceilings, one for each job level above the second, and that the glass ceiling is a p...

  20. In vivo dissolution measurement with indium-111 summation peak ratios

    International Nuclear Information System (INIS)

    Jay, M.; Woodward, M.A.; Brouwer, K.R.

    1985-01-01

    Dissolution of [ 111 In]labeled tablets was measured in vivo in a totally noninvasive manner by using a modification of the perturbed angular correlation technique known as the summation peak ratio method. This method, which requires the incorporation of only 10-12 microCi into the dosage form, provided reliable dissolution data after oral administration of [ 111 In]lactose tablets. These results were supported by in vitro experiments which demonstrated that the dissolution rate as measured by the summation peak ratio method was in close agreement with the dissolution rate of salicylic acid in a [ 111 In]salicylic acid tablet. The method has the advantages of using only one detector, thereby avoiding the need for complex coincidence counting systems, requiring less radioactivity, and being potentially applicable to a gamma camera imaging system

  1. Configurational entropy measurements in extremely supercooled liquids that break the glass ceiling

    Science.gov (United States)

    Berthier, Ludovic; Charbonneau, Patrick; Coslovich, Daniele; Ninarello, Andrea; Ozawa, Misaki; Yaida, Sho

    2017-10-01

    Liquids relax extremely slowly on approaching the glass state. One explanation is that an entropy crisis, because of the rarefaction of available states, makes it increasingly arduous to reach equilibrium in that regime. Validating this scenario is challenging, because experiments offer limited resolution, while numerical studies lag more than eight orders of magnitude behind experimentally relevant timescales. In this work, we not only close the colossal gap between experiments and simulations but manage to create in silico configurations that have no experimental analog yet. Deploying a range of computational tools, we obtain four estimates of their configurational entropy. These measurements consistently confirm that the steep entropy decrease observed in experiments is also found in simulations, even beyond the experimental glass transition. Our numerical results thus extend the observational window into the physics of glasses and reinforce the relevance of an entropy crisis for understanding their formation.

  2. Breaking the glass ceiling: Configurational entropy measurements in extremely supercooled liquids

    Science.gov (United States)

    Berthier, Ludovic

    Liquids relax extremely slowly on approaching the glass state. One explanation is that an entropy crisis, due to the rarefaction of available states, makes it increasingly arduous to reach equilibrium in that regime. Validating this scenario is challenging, because experiments offer limited resolution, while numerical studies lag more than eight orders of magnitude behind experimentally-relevant timescales. In this work we not only close the colossal gap between experiments and simulations but manage to create in-silico configurations that have no experimental analog yet. Deploying a range of computational tools, we obtain four independent estimates of their configurational entropy. These measurements consistently indicate that the steep entropy decrease observed in experiments is found in simulations even beyond the experimental glass transition. Our numerical results thus open a new observational window into the physics of glasses and reinforce the relevance of an entropy crisis for understanding their formation.

  3. Using Energy Peaks to Measure New Particle Masses

    CERN Document Server

    Agashe, Kaustubh; Kim, Doojin

    2014-01-01

    We discussed in arXiv:1209.0772 that the laboratory frame distribution of the energy of a massless particle from a two-body decay at a hadron collider has a peak whose location is identical to the value of this daughter's (fixed) energy in the rest frame of the corresponding mother particle. For that result to hold we assumed that the mother is unpolarized and has a generic boost distribution in the laboratory frame. In this work we discuss how this observation can be applied for determination of masses of new particles, without requiring a full reconstruction of their decay chains or information about the rest of the event. We focus on a two-step cascade decay of a massive particle that has one invisible particle in the final state: C -> Bb -> Aab, where C, B and A are new particles of which A is invisible and a, b are visible particles. Combining the measurements of the peaks of energy distributions of a and b with that of the edge in their invariant mass distribution, we demonstrate that it is in principle...

  4. Quantifying the cepstral peak prominence, a measure of dysphonia.

    Science.gov (United States)

    Heman-Ackah, Yolanda D; Sataloff, Robert T; Laureyns, Griet; Lurie, Deborah; Michael, Deirdre D; Heuer, Reinhardt; Rubin, Adam; Eller, Robert; Chandran, Swapna; Abaza, Mona; Lyons, Karen; Divi, Venu; Lott, Joanna; Johnson, Jennifer; Hillenbrand, James

    2014-11-01

    The purpose of this study is to establish normative values for the smoothed cepstral peak prominence (CPPS) and its sensitivity and specificity as a measure of dysphonia. Prospective cohort study. Voice samples of running speech were obtained from 835 patients and 50 volunteers. Eight laryngologists and four speech-language pathologists performed perceptual ratings of the voice samples on the degree of dysphonia/normality using an analog scale. The mean of their perceptual ratings was used as the gold standard for the detection of the presence or absence of dysphonia. CPPS was measured using the CPPS algorithm of Hillenbrand, and the cut-off value for positivity that has the highest sensitivity and specificity for discriminating between normal and severely dysphonia voices was determined based on ROC-curve analysis. The cut-off value for normal for CPPS was set at 4.0 or higher, which gave a sensitivity of 92.4%, a specificity of 79%, a positive predictive value of 82.5%, and a negative predictive value of 90.8%. The area under the receiver operating characteristic (ROC) curve was 0.937 (P dysphonia, with the normal value of CPPS (Hillenbrand algorithm) of a running speech sample being defined as a value of 4.0 or higher. Copyright © 2014 The Voice Foundation. All rights reserved.

  5. Full Scale Measurements and CFD Simulations of Diffuse Ceiling Inlet for Ventilation and Cooling of Densely Occupied Rooms

    DEFF Research Database (Denmark)

    Mikeska, Tomás; Fan, Jianhua

    2015-01-01

    Spaces with high occupant densities result in high heat gains and need for relatively high air change rate.By means of traditional mechanical ventilation diffusers it becomes a challenge to supply large amountsof fresh air into the space without creating a local discomfort for occupants. One...... comfort numerically. Results of our investigations have shown that diffuse ceiling inlet is a suitable solution for the spaceswith high density occupancy. The results have shown that transient calculations using Large Eddy Simulation models can predict well temperatures and velocity magnitude of air flow...

  6. Determination of the diagnostic x-ray tube practical peak voltage (PPV) from average or average peak voltage measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hourdakis, C J, E-mail: khour@gaec.gr [Ionizing Radiation Calibration Laboratory-Greek Atomic Energy Commission, PO Box 60092, 15310 Agia Paraskevi, Athens, Attiki (Greece)

    2011-04-07

    The practical peak voltage (PPV) has been adopted as the reference measuring quantity for the x-ray tube voltage. However, the majority of commercial kV-meter models measure the average peak, U-bar{sub P}, the average, U-bar, the effective, U{sub eff} or the maximum peak, U{sub P} tube voltage. This work proposed a method for determination of the PPV from measurements with a kV-meter that measures the average U-bar or the average peak, U-bar{sub p} voltage. The kV-meter reading can be converted to the PPV by applying appropriate calibration coefficients and conversion factors. The average peak k{sub PPV,kVp} and the average k{sub PPV,Uav} conversion factors were calculated from virtual voltage waveforms for conventional diagnostic radiology (50-150 kV) and mammography (22-35 kV) tube voltages and for voltage ripples from 0% to 100%. Regression equation and coefficients provide the appropriate conversion factors at any given tube voltage and ripple. The influence of voltage waveform irregularities, like 'spikes' and pulse amplitude variations, on the conversion factors was investigated and discussed. The proposed method and the conversion factors were tested using six commercial kV-meters at several x-ray units. The deviations between the reference and the calculated - according to the proposed method - PPV values were less than 2%. Practical aspects on the voltage ripple measurement were addressed and discussed. The proposed method provides a rigorous base to determine the PPV with kV-meters from U-bar{sub p} and U-bar measurement. Users can benefit, since all kV-meters, irrespective of their measuring quantity, can be used to determine the PPV, complying with the IEC standard requirements.

  7. Measurement of peak temperature along an optical fiber

    International Nuclear Information System (INIS)

    Fox, R.J.

    1983-01-01

    A multimode silica-clad optical fiber with a liquid silicone core was used as a distributed-line peak-temperature sensor over a temperature range from ambient to 190 0 C. The maximum error was 2 0 C and was essentially independent of the length or position of the hot zone

  8. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per Kvols

    cooling capacity, energy saving, low investment cost and low noise level; while the limitations include condensation risk and the limit on the room geometry. Furthermore, the crucial design parameters are summarized and their effects on the system performance are discussed. In addition to the stand...... is not well structured with this system. These become the motivations in developing the design guide. This design guide aims to establish a systematic understanding of diffuse ceiling ventilation and provide assistance in designing of such a system. The guide is targeted at design engineers, architects...... and manufacturers and the users of diffuse ceiling technology. The design guide introduces the principle and key characteristics of room air distribution with diffuse ceiling ventilation. It provides an overview of potential benefit and limitations of this technology. The benefits include high thermal comfort, high...

  9. Bayesian statistical evaluation of peak area measurements in gamma spectrometry

    International Nuclear Information System (INIS)

    Silva, L.; Turkman, A.; Paulino, C.D.

    2010-01-01

    We analyze results from determinations of peak areas for a radioactive source containing several radionuclides. The statistical analysis was performed using Bayesian methods based on the usual Poisson model for observed counts. This model does not appear to be a very good assumption for the counting system under investigation, even though it is not questioned as a whole by the inferential procedures adopted. We conclude that, in order to avoid incorrect inferences on relevant quantities, one must proceed to a further study that allows us to include missing influence parameters and to select a model explaining the observed data much better.

  10. Glass ceilings of professionalisation.

    Science.gov (United States)

    Stott, Dawn L

    2016-04-01

    The term glass ceiling is a political term often used to describe an unbreakable barrier that isnot visible with the human eye, but it keeps minorities from rising up i.e. it is a barrier to minoritygroups, in the past (and sometimes still) for women, that stops them from achieving theirtrue potential.

  11. What Glass Ceiling?

    Science.gov (United States)

    Lynch, Michael; Post, Katherine

    1996-01-01

    A recent study drawing on data from the Census Bureau and the Bureau of Labor Statistics suggests that the wage gap between men and women has virtually disappeared, and that the so-called "glass ceiling" results more from age and qualifications than from explicit discrimination. (SLD)

  12. Stars on the Ceiling

    Science.gov (United States)

    Krupp, E. C.

    2016-01-01

    Astronomy and celestial imagery have been incorporated into architectural ceilings from antiquity to the present to reference the sky on behalf of a variety of agendas. Burial chambers in Egyptian pyramids and tombs, the Osiris chapel on the roof of Ptolemaic Egypt's Temple of Dendera, ancient Chinese tombs, painted rock shelters in California and the American Southwest, the cupola above a hot bath from medieval Jordan, elaborately illustrated ceilings in Italian cathedrals and palaces, the main concourse in New York's Grand Central Terminal, and a variety of other public buildings in America all brought the sky inside to convey relationships between the architecture, people, and the cosmos. In these interior environments, the symbolic function of the astronomical ceiling is driven by the thematic function of the building. At Griffith Observatory in Los Angeles three signature spaces are equipped with astronomically illustrated ceilings. In content and location, these prominent murals operate symbolically to convey meaning through public display and unexpectedly prompt people to think more expansively about the universe. This artwork is familiar in Los Angeles, but its use in a public observatory puts it outside the range of most commentaries on public art. Although experienced by more than seventy-six million persons over the last eighty years, Griffith Observatory's celestial murals are not well known. Their history, content, character, meaning, and purpose are detailed here.

  13. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per Kvols

    with conventional ventilation systems (mixing or displacement ventilation), diffuse ceiling ventilation can significantly reduce or even eliminate draught risk in the occupied zone. Moreover, this ventilation system presents a promising opportunity for energy saving, because of the low pressure loss, extended free...

  14. ENERGY STAR Certified Ceiling Fans

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Ceiling Fans that are effective as of April 1, 2012. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=ceiling_fans.pr_crit_ceiling_fans

  15. Improvement of psychometric properties of a scale measuring inpatient satisfaction with care: a better response rate and a reduction of the ceiling effect

    Directory of Open Access Journals (Sweden)

    Lombrail Pierre

    2007-12-01

    Full Text Available Abstract Background The objective was to solve two problems of an already validated scale measuring inpatient opinion on care: 1 a high non-response rate for some items due to the "not applicable" response option and 2 a skewed score distribution with high ceiling effect. Methods The EQS-H scale ("échelle de qualité des soins en hospitalisation" comprised 26 items and 2 sub-scales of 13 items each, 'quality of medical information' (MI and 'relationships with staff and daily routine' (RS. Three studies were conducted: a first mono-centre study (n = 552, response rate = 83.4%, self-completion of the scale the day before discharge to construct a shorter version of the scale without the items with high non-response rate and maintaining those useful to ensure good internal validity (construct, convergent and divergent and reliability; a second mono-centre study (n = 1246, response rate = 77.9%, self-completion of the scale before discharge to confirm psychometric properties of the new version; a third multi-centre national study (n = 886, response rate 41.7%, self-completion at home 15 days after discharge to test a new response pattern in order to reduce ceiling effect. Results Six items having a non-response rate >20% were deleted, increasing rates of exhaustive response to all items from 15% to 48%. Factorial analysis supported the evidence for removing 4 more items to ensure good internal validity and reliability of the new version. These good results (initial variance explained: 43%; Cronbach's α: 0.80 (MI and 0.81 (RS were confirmed by the second study. The new response format produced a normalisation of the 2 scores with a large decrease in ceiling effect (25% to 4% for MI subscale and 61% to 8% for RS. Psychometric properties of the final version were excellent: the 2 subscales (8 items each explained 66% of the variance in principal component analysis, Cronbach's α were respectively 0.92 (MI and 0.93 (RS. Conclusion The new version of

  16. Breaking the glass ceiling.

    Science.gov (United States)

    Lazarus, A

    1997-03-01

    The glass ceiling is a form of organizational bias and discrimination that prevents qualified professionals from achieving positions of top governance and leadership. This article examines glass ceiling barriers that keep physicians from the upper reaches of management. While these factors apply mainly to women and minority physicians in academia, and are attributable to sexual harassment and discrimination, physicians as a class are frequently denied executive management positions. Such denial results from inadequate preparation for a career in health care administration. Important issues in the professional development of physician executives include mentoring, training and education, administrative experience, and cultural and personality factors. All of those must be considered when making the transition from medicine to management.

  17. Diffuse Ceiling Inlet Systems and the Room Air Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Jensen, Rasmus Lund; Rong, Li

    2010-01-01

    A diffuse ceiling inlet system is an air distribution system which is supplying the air through the whole ceiling. The system can remove a large heat load without creating draught in the room. The paper describes measurements in the case of both cooling and heating, and CFD predictions are given...

  18. Filtration influence in a constant potential X-ray machine peak voltage measurements

    Energy Technology Data Exchange (ETDEWEB)

    Santos, L.R.; Vivolo, V.; Xavier, M.; Potiens, M.P.A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Navarro, M.V.T., E-mail: dossantos.lucasrodrigues@gmail.com [Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia (IFBA), Salvador (Brazil)

    2017-09-01

    This work shows the peak voltage measurements for several beam filtrations used in diagnostic radiology, using two types of non-invasive detectors; a voltage meter and a high-resolution spectrometer. The technique chosen for the voltage peak measurements with the spectrometer was the endpoint. The results were compared to the measured ones and showed good similarity to the nominal values. However the voltage meter detector used in this work presented errors for heavier filtrations. (author)

  19. Effects of a thermal ceiling on postoperative hypothermia

    DEFF Research Database (Denmark)

    Henneberg, S; Eklund, A; Joachimsson, P O

    1985-01-01

    postoperatively with or without external heating from a heating ceiling. Central and peripheral temperatures, oxygen consumption, plasma catecholamines and shivering were measured. A method for continuous measurement of oxygen consumption and carbon dioxide production during spontaneous breathing is described...

  20. Dual-peak dose measurement for radiochromic films by a newly developed spectral microdensitometer

    International Nuclear Information System (INIS)

    Lee, K.Y.; Fung, K.K.L.; Kwok, C.S.

    2005-01-01

    Radiochromic film (RCF) dosimetry is usually based on densitometric methods which use an analyzing light source of a fixed or a broad spectrum of wavelengths. These methods have not exploited the sensitivity of the dose response of the RCF otherwise attainable by using a light source with wavelengths peaked at the two absorption peaks in the absorption spectrum of the RCF. A new algorithm of dual-peak dose measurement for the RCF has been proposed in this paper to make use of these dual absorption peaks to achieve the maximum attainable sensitivity. This technique relies on the measurement of the transmittance of the RCF at the wavelength of the major and minor absorption peaks, respectively. The dual-peak dose measurement is accomplished with the aid of a novel spectral microdensitometer developed in our Institute. The microdensitometer utilizes a monochromator to provide a light source of which the wavelength can be matched precisely to the wavelength of the absorption peaks of the RCF. The doses obtained at these wavelengths are fed into a weighted objective function and an optimum dose is searched by minimizing the objective function to give the best estimate of the dose deposited on the film. An initial test shows that there is a good agreement between the estimated and actual dose deposited; and the maximum discrepancy was found to be less than 1%

  1. MEASURING PRIMORDIAL NON-GAUSSIANITY THROUGH WEAK-LENSING PEAK COUNTS

    International Nuclear Information System (INIS)

    Marian, Laura; Hilbert, Stefan; Smith, Robert E.; Schneider, Peter; Desjacques, Vincent

    2011-01-01

    We explore the possibility of detecting primordial non-Gaussianity of the local type using weak-lensing peak counts. We measure the peak abundance in sets of simulated weak-lensing maps corresponding to three models f NL = 0, - 100, and 100. Using survey specifications similar to those of EUCLID and without assuming any knowledge of the lens and source redshifts, we find the peak functions of the non-Gaussian models with f NL = ±100 to differ by up to 15% from the Gaussian peak function at the high-mass end. For the assumed survey parameters, the probability of fitting an f NL = 0 peak function to the f NL = ±100 peak functions is less than 0.1%. Assuming the other cosmological parameters are known, f NL can be measured with an error Δf NL ∼ 13. It is therefore possible that future weak-lensing surveys like EUCLID and LSST may detect primordial non-Gaussianity from the abundance of peak counts, and provide information complementary to that obtained from the cosmic microwave background.

  2. ENERGY STAR Certified Ceiling Fans

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 3.1 ENERGY STAR Program Requirements for Ceiling Fans that are effective as of April 1,...

  3. Measurements and simulations for peak electrical load reduction in cooling dominated climate

    International Nuclear Information System (INIS)

    Sadineni, Suresh B.; Boehm, Robert F.

    2012-01-01

    Peak electric demand due to cooling load in the Desert Southwest region of the US has been an issue for the electrical energy suppliers. To address this issue, a consortium has been formed between the University of Nevada Las Vegas, Pulte Homes (home builder) and NV Energy (local utility) in order to reduce the peak load by more than 65%. The implemented strategies that were used to accomplish that goal consist of energy efficiency in homes, onsite electricity generation through roof integrated PV, direct load control, and battery storage at the substation level. The simulation models developed using building energy analysis software were validated against measured data. The electrical energy demand for the upgraded home during peak period (1:00–7:00 PM) decreased by approximately 37% and 9% compared to a code standard home of the same size, due to energy efficiency and PV generation, respectively. The total decrease in electrical demand due to energy efficiency and PV generation during the peak period is 46%. Additionally, a 2.2 °C increase in thermostat temperature from 23.9 °C to 26.1 °C between 4:00 PM and 7:00 PM has further decreased the average demand during the peak period by 69% of demand from a standard home. -- Highlights: ► A study to demonstrate peak load reductions of 65% at the substation. ► A new residential energy efficient community named Villa Trieste is being developed. ► The peak demand from the homes has decreased by 37% through energy efficiency. ► A 1.8 kWp system along with energy efficiency measures decreased peak by 46%.

  4. Activity measurement by using γ-ray sum peak method considering intake radioactivity and its application

    International Nuclear Information System (INIS)

    Miyahara, Hiroshi; Narita, Norihiko; Tomita, Kenichi; Katoh, Yoshichika; Mori, Chizuo; Momose, Takumaro; Shinohara, Kunihiko

    2000-01-01

    It is important to measure external and internal exposure dose in the case of accident. The external exposure can be measured by various dosimeters, but the internal exposure is usually calculated from estimated amounts of intake radioactivity because of difficulty of direct measurement. Detection efficiency of human counter used in direct measurement is necessary, but there is no effective method to determine it for non-uniform distribution. The γ-ray sum peak method is tried for the cascade γ-ray emitter under the consideration of small diffusion such as just after intake. After disintegration rates of sources of 46 Sc and 60 Co were determined by 4πβ-γ coincidence method, γ-ray spectra were measured at various positions. Calculated disintegration rates by sum peak method agreed with those by coincidence method within 10%. The similar results were obtained for distributed plural sources in restricted condition. It is also investigated as application for the case that the other nuclide is contained in it. Using peak-to-total ratios measured in advance, the disintegration rates were determined only from the peak intensities. In this case the results had systematic uncertainty of about 20%. (author)

  5. Experimental evaluation of IGBT junction temperature measurement via peak gate current

    DEFF Research Database (Denmark)

    Baker, Nick; Munk-Nielsen, Stig; Iannuzzo, Francesco

    2015-01-01

    Temperature sensitive electrical parameters allow junction temperature measurements on power semiconductors without modification to module packaging. The peak gate current has recently been proposed for IGBT junction temperature measurement and relies on the temperature dependent resistance...... of the gate pad. Consequently, a consideration of chip geometry and location of the gate pad is required before interpreting temperature data from this method. Results are also compared with a traditional electrical temperature measurement method: the voltage drop under low current....

  6. Measuring saccade peak velocity using a low-frequency sampling rate of 50 Hz.

    Science.gov (United States)

    Wierts, Roel; Janssen, Maurice J A; Kingma, Herman

    2008-12-01

    During the last decades, small head-mounted video eye trackers have been developed in order to record eye movements. Real-time systems-with a low sampling frequency of 50/60 Hz-are used for clinical vestibular practice, but are generally considered not to be suited for measuring fast eye movements. In this paper, it is shown that saccadic eye movements, having an amplitude of at least 5 degrees, can, in good approximation, be considered to be bandwidth limited up to a frequency of 25-30 Hz. Using the Nyquist theorem to reconstruct saccadic eye movement signals at higher temporal resolutions, it is shown that accurate values for saccade peak velocities, recorded at 50 Hz, can be obtained, but saccade peak accelerations and decelerations cannot. In conclusion, video eye trackers sampling at 50/60 Hz are appropriate for detecting the clinical relevant saccade peak velocities in contrast to what has been stated up till now.

  7. Peak Measurement for Vancomycin AUC Estimation in Obese Adults Improves Precision and Lowers Bias.

    Science.gov (United States)

    Pai, Manjunath P; Hong, Joseph; Krop, Lynne

    2017-04-01

    Vancomycin area under the curve (AUC) estimates may be skewed in obese adults due to weight-dependent pharmacokinetic parameters. We demonstrate that peak and trough measurements reduce bias and improve the precision of vancomycin AUC estimates in obese adults ( n = 75) and validate this in an independent cohort ( n = 31). The precision and mean percent bias of Bayesian vancomycin AUC estimates are comparable between covariate-dependent ( R 2 = 0.774, 3.55%) and covariate-independent ( R 2 = 0.804, 3.28%) models when peaks and troughs are measured but not when measurements are restricted to troughs only ( R 2 = 0.557, 15.5%). Copyright © 2017 American Society for Microbiology.

  8. Glass Ceiling : Women in management

    OpenAIRE

    Rantala, Virve

    2010-01-01

    This study has examined the phenomenon called Glass Ceiling. It has approached the phenomenon in two different views. One is career development and another one is women in management. Main purpose for this study was to inspect women working life and career opportunities. Why women’s career developments end in a certain level? What is glass ceiling and how to break it? Paper also investigates reasons behind the effect. Prejudices and biases are the worst enemies for women’s career. How to chan...

  9. Peak power factor determination of the RA-6 Argentinean Research Reactor using measurement-calculations correlations

    International Nuclear Information System (INIS)

    Sanchez, F. A.; Blaumann, H.; Lopasso, E.; Longhino, J

    2009-01-01

    The maximum power of a reactor is limited by the power peaking factor. During the design stage it is calculated with neutronic calculation codes. This is not enough for ensuring its value due to modelling approximations. For the RA-6s low enrichment new core a calculus-measurement correlation method have been applied. Position and magnitude of the maximum power density estimated by calculus are used by this method. For this work 249 cooper-gold alloy (1.55% Au) wires have been distributed along the core using 19 aluminium blades. Their positions have been selected using information given by a 5 groups PUMA reactor model. Wire s activity have been measured with a HPGe detector. Gold activity have been used only for verifying the calculated core spectrum. The measured power peaking factor was 2.48±0.3 (3σ), 15% above the calculated value. About 97% of measured points had less than 20% calculation-measurement difference and about 80% had less than 10%. The power peaking factor determined by this method consolidates also the calculations models. [es

  10. Operational and structural measures to reduce hydro-peaking impact on fish larvae

    International Nuclear Information System (INIS)

    Kopecki, Ianina; Schneider, Matthias

    2016-01-01

    Eco-hydraulic investigations studying the effects of hydro-peaking on river biota are gaining in importance. Negative effects of rapid flow fluctuations due to hydro power production are well documented by many studies, with the larvae and juvenile fish identified among the mostly affected life stages. Therefore, elaboration of efficient hydro-peaking mitigation strategies is an important issue for energy companies as well as for water body administrations responsible for the fulfilment of WFD requirements. The present case study strives for practical solutions allowing to minimize or compensate the negative effects of hydro-peaking on the fish fauna of the 7 km long river reach on the river Lech (southern Germany). Model based investigations allow to access the impact from currently authorized discharge regime, suggest operational and structural measures within the reach in terms of reducing the risk of stranding for fish larvae and select the measures most easy to implement and with the largest ecological benefit. The paper describes the approach for accessing the effects of hydro-peaking based on 2D hydrodynamic modelling, fuzzy logic based habitat modelling and information on cutting-edge biological investigations on fish larvae from Lunz experimental facility (Austria). (authors)

  11. The measurement of mass spectrometric peak height ratio of helium isotope in trace samples

    International Nuclear Information System (INIS)

    Sun Mingliang

    1989-01-01

    An experiment study on the measurement of mass spectrometric peak height ratio of helium isotope in the trace gaseous sample is discussed by using the gas purification line designed by the authors and model VG-5400 static-vacuum noble gas mass spectrometer imported and air helium as a standard. The results show that the amount of He and Ne in natural gas sample is 99% after purification. When the amount of He in Mass Spectrometer is more than 4 x 10 -7 cm 3 STP, it's sensitivity remains stable, about 10 -4 A/cm 3 STP He and the precision of 3 He/ 4 He ratio within the following 17 days is 1.32%. The 'ABA' pattern and experiment condition in the measurement of mass spectrometric peak height ratio of He isotope are presented

  12. On Some Statistical Properties of GRBs with Measured Redshifts Having Peaks in Optical Light Curves

    Directory of Open Access Journals (Sweden)

    Grigorii Beskin

    2013-01-01

    Full Text Available We studied the subset of optical light curves of gamma-ray bursts with measured redshifts and well-sampled R band data that have clearly detected peaks. Among 43 such events, 11 are promptoptical peaks (P, coincident with gamma-ray activity, 22 are purely afterglows (A, and 10 more carrythe signatures of an underlying activity (A(U. We studied pair correlations of their gamma-ray andoptical parameters, e.g. total energetics, peak optical luminosities, and durations. The main outcomeof our study is the detection of source frame correlations between both optical peak luminosity and total energy and the redshift for classes A and A(U, and the absence of such a correlation for class Pevents. This result seems to provide evidence of the cosmological evolution of a medium around the burst defining class A and A(U energetics, and the absence of cosmological evolution of the internal properties of GRB engines. We also discuss some other prominent correlations.

  13. Evaluation of ceiling lifts in health care settings: patient outcome and perceptions.

    Science.gov (United States)

    Alamgir, Hasanat; Li, Olivia Wei; Gorman, Erin; Fast, Catherine; Yu, Shicheng; Kidd, Catherine

    2009-09-01

    Ceiling lifts have been introduced into health care settings to reduce manual patient lifting and thus occupational injuries. Although growing evidence supports the effectiveness of ceiling lifts, a paucity of research links indicators, such as quality of patient care or patient perceptions, to the use of these transfer devices. This study explored the relationship between ceiling lift coverage rates and measures of patient care quality (e.g., incidence of facility-acquired pressure ulcers, falls, urinary infections, urinary incontinence, and assaults [patient to staff] in acute and long-term care facilities), as well as patient perceptions of satisfaction with care received while using ceiling lifts in a complex care facility. Qualitative semi-structured interviews were used to generate data. A significant inverse relationship was found between pressure ulcer rates and ceiling lift coverage; however, this effect was attenuated by year. No significant relationships existed between ceiling lift coverage and patient outcome indicators after adding the "year" variable to the model. Patients generally approved of the use of ceiling lifts and recognized many of the benefits. Ceiling lifts are not detrimental to the quality of care received by patients, and patients prefer being transferred by ceiling lifts. The relationship between ceiling lift coverage and pressure ulcer rates warrants further investigation. Copyright (c) 2009, SLACK Incorporated.

  14. The effect of diffuse ceiling panel on the energy performance of thermally activated building construction

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Pomianowski, Michal Zbigniew

    2016-01-01

    An integrated system combining diffuse ceiling ventilation with thermally activated building construction (TABS) was proposed recently. In this system, TABS is encapsulated by diffuse ceiling panel and cannot have directly heat exchange with the room. The aim of this study is to investigate...... the effect of diffuse ceiling panel on the energy performance of TABS in both heat and cooling mode. Experiments are carried out in a full-scale test facility with the integrated system, and the cases without diffuse ceiling are also measured as references. The results indicate that the diffuse ceiling has...... an opposite effect on the heating and cooling capacity of TABS. In addition, a numerical model is built and validated by the measured data. The validated model is further applied to conduct a paramedical study on the materials of the diffuse ceiling panel....

  15. Measurements of Ion Stopping around the Bragg Peak in High-Energy-Density Plasmas

    Science.gov (United States)

    Frenje, Johan

    2015-11-01

    Over the last few decades, ion stopping in weakly- to strongly-coupled High-Energy-Density (HED) plasmas has been subject to extensive analytical and numerical studies, but only a limited set of experimental data exists to check the validity of these theories. Most of these experiments also did not probe the detailed characteristics of the Bragg peak (peak ion stopping) where the ion velocity is similar to the average thermal electron velocity. To the best of our knowledge, only one exploratory attempt to do this was conducted by Hicks et al., who were able to describe qualitatively the behavior of the Bragg peak for one plasma condition. The work described in this presentation makes significant advances over previous experimental efforts by quantitatively assessing the characteristics of the ion stopping, ranging from low-velocity stopping, through the Bragg peak, to high-velocity stopping for different HED plasma conditions. This was achieved by measuring the energy loss of DD-tritons, D3He-alphas, DD-protons and D3He-protons, with distinctly different velocities, and the results indicate that the stopping power varies strongly with Te and ne. This effort represents the first experimental test of state-of-art plasma-stopping-power theories around the Bragg peak, which is an important first step in our efforts of getting a fundamental understanding of DT-alpha stopping in HED plasmas, a prerequisite for understanding ignition margins in various implosion designs with varying hot spot areal density at the National Ignition Facility. The work described here was performed in part at the LLE National Laser User's Facility (NLUF), and was supported in part by US DOE (Grant No. DE-FG03- 03SF22691), LLNL (subcontract Grant No. B504974) and LLE (subcontract Grant No. 412160-001G).

  16. Jagged Edges of the Glass Ceiling

    Science.gov (United States)

    Robinson, Victoria L.

    2004-01-01

    Although many aspiring young women might believe the glass ceiling was shattered a decade ago, they still need to understand how that glass ceiling impacted an older generation of women in educational leadership. They also must be aware that some segments of the glass ceiling might still exist. This article provides a historical overview of the…

  17. The correlation between superparamagnetic blocking temperatures and peak temperatures obtained from ac magnetization measurements

    International Nuclear Information System (INIS)

    Madsen, Daniel Esmarch; Moerup, Steen; Hansen, Mikkel Fougt

    2008-01-01

    We study the correlation between the superparamagnetic blocking temperature T B and the peak positions T p observed in ac magnetization measurements for nanoparticles of different classes of magnetic materials. In general, T p = α+βT B . The parameters α and β are different for the in-phase (χ') and out-of-phase (χ'') components and depend on the width σ V of the log-normal volume distribution and the class of magnetic material (ferromagnetic/antiferromagnetic). Consequently, knowledge of both α and β is required if the anisotropy energy barrier KV and the attempt time τ 0 are to be reliably obtained from an analysis based solely on the peak positions

  18. Calibration of kV measurers with the practical peak voltage (IEC 1676)

    International Nuclear Information System (INIS)

    Becker, Paulo H.B.; Peres, Marcos A.L.; Ludwig, Jaime L.; Chernicharo, Carlos C.

    2002-01-01

    The IEC 1676 standard introduces a new quantity for the measurements of the high voltages applied to the X ray tubes used for diagnosis, the 'Practical Peak Voltage' (PPV). In order to start the introduction of this new quantity in Brazil the National Laboratory for Metrology of Ionizing Radiation has developed a procedure for calibrating measuring instruments in this quantity. This procedure is based in the same set up used for the calibration of the conventional kVp, which consists in a high voltage divider (Dynalyser III from Radcal Corporation), a fast analogue to digital conversion board and a data acquisition software. In order to evaluate this procedure a commercial kVp measure instrument that is able to measure PPV (Universal Diavolt from PTW) was calibrated and the results compared. This work presents a summary of the procedure developed and the results obtained with the comparison. (author)

  19. Systolic peak detection in acceleration photoplethysmograms measured from emergency responders in tropical conditions.

    Science.gov (United States)

    Elgendi, Mohamed; Norton, Ian; Brearley, Matt; Abbott, Derek; Schuurmans, Dale

    2013-01-01

    Photoplethysmogram (PPG) monitoring is not only essential for critically ill patients in hospitals or at home, but also for those undergoing exercise testing. However, processing PPG signals measured after exercise is challenging, especially if the environment is hot and humid. In this paper, we propose a novel algorithm that can detect systolic peaks under challenging conditions, as in the case of emergency responders in tropical conditions. Accurate systolic-peak detection is an important first step for the analysis of heart rate variability. Algorithms based on local maxima-minima, first-derivative, and slope sum are evaluated, and a new algorithm is introduced to improve the detection rate. With 40 healthy subjects, the new algorithm demonstrates the highest overall detection accuracy (99.84% sensitivity, 99.89% positive predictivity). Existing algorithms, such as Billauer's, Li's and Zong's, have comparable although lower accuracy. However, the proposed algorithm presents an advantage for real-time applications by avoiding human intervention in threshold determination. For best performance, we show that a combination of two event-related moving averages with an offset threshold has an advantage in detecting systolic peaks, even in heat-stressed PPG signals.

  20. Study of the peak shape in alpha spectra measured by liquid scintillation

    CERN Document Server

    Vera-Tome, F; Martin-Sanchez, A

    2002-01-01

    Liquid-scintillation counting allows the measurement of alpha and beta activities jointly or only of the alpha-emitting nuclides in a sample. Although the resolution of the alpha spectra is poorer than that attained with semiconductor detectors, it is still an attractive alternative. We describe here attempts to fit a peak shape to experimental liquid-scintillation alpha spectra and discuss the parameters affecting this shape, such as the PSA (pulse-shape analyser) level, vial type, shaking the sample, etc. Spectral analysis has been applied for complex alpha spectra.

  1. Measurements of bundle end flux peaking effects in 37-element CANDU PHW fuel

    International Nuclear Information System (INIS)

    French, P.M.

    1977-10-01

    Thermal neutron bundle end flux peaking factors have been measured in fresh 37-element Bruce reactor natural UO 2 clusters in heavy water moderator, both with and without staggered plenums at the fuel stack ends, in representative elements throughout the clusters. The measurements were made at a square lattice pitch of 28.58 cm with heavy water coolant. The results indicate that outer element peaking factors are 1.142 +- 0.009 for bundles containing no plenums, and 1.155 +- 0.006 and 1.177 +- 0.006 at the non-plenum and plenum element ends respectively, for bundles containing staggered plenums, irrespective of the azimuthal orientation between pairs of bundles. Measurements are also reported for bundles containing plenums in every outer element, for bundles separated by a stainless steel flux suppressor, for longer graphite plenums, and for changes in plenum and bundle gap lengths. Some theoretical comparisons with the results, reported by other authors, have been summarized. (author)

  2. An Automated Measurement of Ciliary Beating Frequency using a Combined Optical Flow and Peak Detection.

    Science.gov (United States)

    Kim, Woojae; Han, Tae Hwa; Kim, Hyun Jun; Park, Man Young; Kim, Ku Sang; Park, Rae Woong

    2011-06-01

    The mucociliary transport system is a major defense mechanism of the respiratory tract. The performance of mucous transportation in the nasal cavity can be represented by a ciliary beating frequency (CBF). This study proposes a novel method to measure CBF by using optical flow. To obtain objective estimates of CBF from video images, an automated computer-based image processing technique is developed. This study proposes a new method based on optical flow for image processing and peak detection for signal processing. We compare the measuring accuracy of the method in various combinations of image processing (optical flow versus difference image) and signal processing (fast Fourier transform [FFT] vs. peak detection [PD]). The digital high-speed video method with a manual count of CBF in slow motion video play, is the gold-standard in CBF measurement. We obtained a total of fifty recorded ciliated sinonasal epithelium images to measure CBF from the Department of Otolaryngology. The ciliated sinonasal epithelium images were recorded at 50-100 frames per second using a charge coupled device camera with an inverted microscope at a magnification of ×1,000. The mean square errors and variance for each method were 1.24, 0.84 Hz; 11.8, 2.63 Hz; 3.22, 1.46 Hz; and 3.82, 1.53 Hz for optical flow (OF) + PD, OF + FFT, difference image [DI] + PD, and DI + FFT, respectively. Of the four methods, PD using optical flow showed the best performance for measuring the CBF of nasal mucosa. The proposed method was able to measure CBF more objectively and efficiently than what is currently possible.

  3. Estimation of uncertainty bounds for individual particle image velocimetry measurements from cross-correlation peak ratio

    International Nuclear Information System (INIS)

    Charonko, John J; Vlachos, Pavlos P

    2013-01-01

    Numerous studies have established firmly that particle image velocimetry (PIV) is a robust method for non-invasive, quantitative measurements of fluid velocity, and that when carefully conducted, typical measurements can accurately detect displacements in digital images with a resolution well below a single pixel (in some cases well below a hundredth of a pixel). However, to date, these estimates have only been able to provide guidance on the expected error for an average measurement under specific image quality and flow conditions. This paper demonstrates a new method for estimating the uncertainty bounds to within a given confidence interval for a specific, individual measurement. Here, cross-correlation peak ratio, the ratio of primary to secondary peak height, is shown to correlate strongly with the range of observed error values for a given measurement, regardless of flow condition or image quality. This relationship is significantly stronger for phase-only generalized cross-correlation PIV processing, while the standard correlation approach showed weaker performance. Using an analytical model of the relationship derived from synthetic data sets, the uncertainty bounds at a 95% confidence interval are then computed for several artificial and experimental flow fields, and the resulting errors are shown to match closely to the predicted uncertainties. While this method stops short of being able to predict the true error for a given measurement, knowledge of the uncertainty level for a PIV experiment should provide great benefits when applying the results of PIV analysis to engineering design studies and computational fluid dynamics validation efforts. Moreover, this approach is exceptionally simple to implement and requires negligible additional computational cost. (paper)

  4. Performance analysis of a new design of office diffuse ceiling ventilation system

    DEFF Research Database (Denmark)

    Fan, Jianhua; Hviid, Christian Anker; Yang, Honglu

    2013-01-01

    This paper aims to document and analyse performance of a new design of diffuse ceiling ventilation system in a typical office room. A full scale measurement is carried out in a climate chamber with an office setup at the Technical University of Denmark. Indoor air temperatures, air speeds, wall...... surface temperatures, pressure loss of the ceiling and ventilation effectiveness are measured for an air change rate of 3.5 h-1 and 5.1 h -1 respectively. A computational fluid dynamics model of the office with the diffuse ceiling ventilation system is built and validated by the full scale measurement....... The measurements of pressure loss across the ceiling show a low pressure drop between the plenum and the occupied zone. Ventilation effectiveness is measured to be close to 1 on average under the tested conditions. It is shown that the diffuse ceiling ventilation system is able to remove indoor pollutant...

  5. Armored glass university ceilings

    Directory of Open Access Journals (Sweden)

    Ana Guil Bozal

    2016-12-01

    Full Text Available The barriers that women face to occupy the highest professional positions are well studied, yet they persist. The employment situation of women has improved, but the positions of power are still predominantly in male hands, as if men continually seek new mechanisms to keep, like viruses that change every year to survive the way vaccines. Barriers persist, although in recent decades women have managed to overcome in quantity and quality to men among university students. Women are still unable to access the best academic positions. Among university faculty only reach 40% and full professor position remain masculinized, having managed to reach the women -after many efforts and some policies- measures only 20%, which is seen clearly insufficient given their greater training. Against this background, the future is difficult, unless the university decided to endorse the cause of equality, going to assume its role of reference for the new generations and to other organizations and society in general.

  6. Modeling of Ceiling Fire Spread and Thermal Radiation.

    Science.gov (United States)

    1981-10-01

    under a PMMA ceiling and flame lengths under an inert ceiling are found to be in reasonable agreement with full-scale behavior. Although fire spread...5 3 Flame Lengths under Full-Scale Ceilings 12 4 Correlation of Flame Length under Inert Ceilings 16 5 Correlation of Flame Length under No 234 Model...Ceilings 17 6 Correlation of Flame Length under No B8811 Model Ceilings 18 7 Correlation of Flame Length under No. 223 Model Ceilings 19 8

  7. Validity of peak expiratory flow measurement in assessing reversibility of airflow obstruction.

    Science.gov (United States)

    Dekker, F W; Schrier, A C; Sterk, P J; Dijkman, J H

    1992-01-01

    BACKGROUND: Assessing the reversibility of airflow obstruction by peak expiratory (PEF) measurements would be practicable in general practice, but its usefulness has not been investigated. METHODS: PEF measurements were performed (miniWright peak flow meter) in 73 general practice patients (aged 40 to 84) with a history of asthma or chronic obstructive lung disease before and after 400 micrograms inhaled sulbutamol. The change in PEF was compared with the change in forced expiratory volume in one second (FEV1). Reversible airflow obstruction was analysed in two ways according to previous criteria. When defined as a 9% or greater increase in FEV1 expressed as a percentage of predicted values reversibility was observed in 42% of patients. Relative operating characteristic analysis showed that an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (the sensitivity and specificity of an increase of 60 l/min in detecting a 9% or more increase in FEV1 as a percentage of predicted values were 68% and 93% respectively, with a positive predictive value of 87%). When defined as an increase of 190 ml or more in FEV1, reversible airflow obstruction was observed in 53% of patients. Again an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (sensitivity 56%, specificity 94%, and positive predictive value 92%). CONCLUSION: Absolute changes in PEF can be used as a simple technique to diagnose reversible airflow obstruction in patients from general practice. PMID:1519192

  8. An Economic Theory of Glass Ceiling

    OpenAIRE

    Paul A. Grout; In-Uck Park; Silvia Sonderegger

    2009-01-01

    In the 'glass ceiling' debate there appear to be two strongly held and opposing interpretations of the evidence, one suggesting it is really the result of gender differences and the other that there is discrimination by gender. This paper provides an economic theory of the glass ceiling and one of the main insights of our analysis is that in some real sense these two interpretations are not in conflict with each other. The glass ceiling emerges as an equilibrium phenomenon when firms compete ...

  9. Find - a computer program for peak search in gamma-ray spectra measured with Ge (Li) detectors

    International Nuclear Information System (INIS)

    Venturini, L.

    1988-01-01

    The program FIND is a FORTRAN IV computer code for peak search in spectra measured with Ge(Li) detectors. The program gives the position and estimates energy and relative significance for every peak found in the spectrum. The search in done by calculating a negative smoothed second difference of the experimental spectrum, as suggested by Phillips and Marlow (1). (author) [pt

  10. Measurement of peak impact loads differ between accelerometers - Effects of system operating range and sampling rate.

    Science.gov (United States)

    Ziebart, Christina; Giangregorio, Lora M; Gibbs, Jenna C; Levine, Iris C; Tung, James; Laing, Andrew C

    2017-06-14

    A wide variety of accelerometer systems, with differing sensor characteristics, are used to detect impact loading during physical activities. The study examined the effects of system characteristics on measured peak impact loading during a variety of activities by comparing outputs from three separate accelerometer systems, and by assessing the influence of simulated reductions in operating range and sampling rate. Twelve healthy young adults performed seven tasks (vertical jump, box drop, heel drop, and bilateral single leg and lateral jumps) while simultaneously wearing three tri-axial accelerometers including a criterion standard laboratory-grade unit (Endevco 7267A) and two systems primarily used for activity-monitoring (ActiGraph GT3X+, GCDC X6-2mini). Peak acceleration (gmax) was compared across accelerometers, and errors resulting from down-sampling (from 640 to 100Hz) and range-limiting (to ±6g) the criterion standard output were characterized. The Actigraph activity-monitoring accelerometer underestimated gmax by an average of 30.2%; underestimation by the X6-2mini was not significant. Underestimation error was greater for tasks with greater impact magnitudes. gmax was underestimated when the criterion standard signal was down-sampled (by an average of 11%), range limited (by 11%), and by combined down-sampling and range-limiting (by 18%). These effects explained 89% of the variance in gmax error for the Actigraph system. This study illustrates that both the type and intensity of activity should be considered when selecting an accelerometer for characterizing impact events. In addition, caution may be warranted when comparing impact magnitudes from studies that use different accelerometers, and when comparing accelerometer outputs to osteogenic impact thresholds proposed in literature. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  11. Hydration-coupled protein boson peak measured by incoherent neutron scattering

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi; Kataoka, Mikio; Joti, Yasumasa; Kitao, Akio; Shibata, Kaoru; Tokuhisa, Atsushi; Tsukushi, Itaru; Go, Nobuhiro

    2006-01-01

    The boson peak of a protein was examined in relation to hydration using staphylococcal nuclease. Although the boson peak is commonly observed in synthetic polymers, glassy materials and amorphous materials, the origin of the boson peak is not fully understood. The motions that contribute to the peak are harmonic vibrations. Upon hydration the peak frequency shifts to a higher frequency and the effective force constant of the vibration increases at low temperatures, suggesting that the protein energy surface is modified. Hydration of the protein leads to a more rugged surface and the vibrational motions are trapped within the local minimum at cryogenic temperatures. The origin of the protein boson peak may be related to this rugged energy surface

  12. Difficulty in obtaining peak expiratory flow measurements in children with acute asthma.

    Science.gov (United States)

    Gorelick, Marc H; Stevens, Molly W; Schultz, Theresa; Scribano, Philip V

    2004-01-01

    To determine the frequency with which children >or=6 years with acute asthma can perform peak expiratory flow rate measurements (PEFR) in an emergency department (ED). Data were obtained from a prospective cohort study of children with acute asthma. All children (age 2-18 years old) treated in an urban pediatric ED for an acute exacerbation during randomly selected days over a 12-month period were prospectively evaluated. According to treatment protocols, PEFR was to be measured in all children age 6 years and older before therapy and after each treatment with inhaled bronchodilators. Registered respiratory therapists obtained PEFR and evaluated whether patients were able to perform the maneuver adequately. Four hundred and fifty-six children, 6 to 18 years old (median 10 years), were enrolled; 291 (64%) had PEFR measured at least once. Of those in whom PEFR was attempted at least once, only 190 (65%) were able to perform adequately. At the start of therapy, 54% (142/262) were able to perform PEFR. Of the 120 who were unable to perform initially, 76 had another attempt at the end of the ED treatment, and 55 (72%) were still unable to perform. A total of 149 patients had attempts at PEFR both at the start and end of treatment, of these, only 71 (48%) provided valid information on both attempts. Patients unable to perform PEFR were younger (mean +/- SD = 8.7 +/- 2.8 years) than those who were able to perform successfully (11.2 +/- 3.2 years) and those with no attempts (10.0 +/- 3.4 years). Children admitted to the hospital were more likely to be unable to perform PEFR (58/126 = 46%) than those discharged from the ED (43/330 = 13%, P < 0.0001). Adequate PEFR measurements are difficult to obtain in children with acute asthma. Treatment and research protocols cannot rely exclusively on PEFR for evaluation of severity.

  13. The Glass Ceiling Initiative. A Report.

    Science.gov (United States)

    Department of Labor, Washington, DC.

    While minorities and women have made considerable gains in entering the workforce in the last few decades, there remains a dearth of minorities and women at management levels. This phenomenon has come to be known as the "glass ceiling." The Department of Labor defines the glass ceiling as those artificial barriers based on attitudinal or…

  14. The Glass Ceiling: Progress and Persistent Challenges

    Science.gov (United States)

    McLlwain, Wendy M.

    2012-01-01

    It has been written that since 2001, there has not been any significant progress and the glass ceiling is still intact. Women are still underrepresented in top positions (Anonymous, 2004). If this is true, the glass ceiling presents a major barrier between women and their desire to advance into executive or senior management positions. In addition…

  15. The glass ceiling in nursing management.

    Science.gov (United States)

    Crawford, D I

    1993-01-01

    Women managers in business and health care have experienced discrimination related to advancement in management. Nurse executives must understand the strategies to overcome the barriers, the "glass ceiling," as well as implications for future practice. Women executives need an organized blueprint and the tools to dismantle the glass ceiling and overcome the political and discriminatory barriers to success.

  16. Comparative Analysis of Mass Spectral Similarity Measures on Peak Alignment for Comprehensive Two-Dimensional Gas Chromatography Mass Spectrometry

    Science.gov (United States)

    2013-01-01

    Peak alignment is a critical procedure in mass spectrometry-based biomarker discovery in metabolomics. One of peak alignment approaches to comprehensive two-dimensional gas chromatography mass spectrometry (GC×GC-MS) data is peak matching-based alignment. A key to the peak matching-based alignment is the calculation of mass spectral similarity scores. Various mass spectral similarity measures have been developed mainly for compound identification, but the effect of these spectral similarity measures on the performance of peak matching-based alignment still remains unknown. Therefore, we selected five mass spectral similarity measures, cosine correlation, Pearson's correlation, Spearman's correlation, partial correlation, and part correlation, and examined their effects on peak alignment using two sets of experimental GC×GC-MS data. The results show that the spectral similarity measure does not affect the alignment accuracy significantly in analysis of data from less complex samples, while the partial correlation performs much better than other spectral similarity measures when analyzing experimental data acquired from complex biological samples. PMID:24151524

  17. Measurement of disintegration rates of 60Co volume sources by the sum-peak method

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1991-01-01

    The sum-peak method has been applied to the determination of the disintegration rates of 60 Co volume sources (1.05 x 10 4 Bq, 1.05 x 10 3 Bq and 1.05 x 10 2 Bq, in 100-ml polyethylene bottles) by using a NaI(Tl) detector of a diameter of 50 mm and a height of 50 mm. The experimental results showed that decreasing the disintegration rates resulted in enlarged underestimation in comparison with the true disintegration rates. It was presumed that the underestimations of the disintegration rates determined by the sum-peak method resulted from the overestimations of the areas under the sum peaks caused by the overlap of the area under the Compton scattering of the γ-ray (2614 keV) emitted from a naturally occurring radionuclide 208 Tl under the sum peaks. (author)

  18. EFFECT OF MEASUREMENT ERRORS ON PREDICTED COSMOLOGICAL CONSTRAINTS FROM SHEAR PEAK STATISTICS WITH LARGE SYNOPTIC SURVEY TELESCOPE

    Energy Technology Data Exchange (ETDEWEB)

    Bard, D.; Chang, C.; Kahn, S. M.; Gilmore, K.; Marshall, S. [KIPAC, Stanford University, 452 Lomita Mall, Stanford, CA 94309 (United States); Kratochvil, J. M.; Huffenberger, K. M. [Department of Physics, University of Miami, Coral Gables, FL 33124 (United States); May, M. [Physics Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); AlSayyad, Y.; Connolly, A.; Gibson, R. R.; Jones, L.; Krughoff, S. [Department of Astronomy, University of Washington, Seattle, WA 98195 (United States); Ahmad, Z.; Bankert, J.; Grace, E.; Hannel, M.; Lorenz, S. [Department of Physics, Purdue University, West Lafayette, IN 47907 (United States); Haiman, Z.; Jernigan, J. G., E-mail: djbard@slac.stanford.edu [Department of Astronomy and Astrophysics, Columbia University, New York, NY 10027 (United States); and others

    2013-09-01

    We study the effect of galaxy shape measurement errors on predicted cosmological constraints from the statistics of shear peak counts with the Large Synoptic Survey Telescope (LSST). We use the LSST Image Simulator in combination with cosmological N-body simulations to model realistic shear maps for different cosmological models. We include both galaxy shape noise and, for the first time, measurement errors on galaxy shapes. We find that the measurement errors considered have relatively little impact on the constraining power of shear peak counts for LSST.

  19. Correlation between peak and median blocking temperatures by magnetization measurement on isolated ferromagnetic and antiferromagnetic particle systems

    DEFF Research Database (Denmark)

    Jiang, Jianzhong; Mørup, Steen

    1997-01-01

    The influence of the particle size distribution on the ratio of the peak temperature, T-peak, to the blocking temperature, T-Bm, in zero field cooled (ZFD) magnetization curves has studied for both ferromagnetic and antiferromagnetic particle systems. In both systems the ratio beta=T-peak/T-Bm does...... not depend on the median particle volume. However, T-Bm can be considerably different from T-peak in both systems. These results show that the ZFD measurements can be used to determine T-Bm values only if the particle size distribution of the system is known. Otherwise, the estimated T-Bm values will have...... a large uncertainty, especially in systems with a broad particle size distribution....

  20. In situ measurements of X-ray peak profile asymmetry from individual grains

    DEFF Research Database (Denmark)

    Wejdemann, Christian; Lienert, U.; Pantleon, Wolfgang

    2010-01-01

    Two copper samples, pre-deformed in tension to 5% plastic strain, are subjected to an in situ tensile deformation of 1% plastic strain while X-ray peak profiles from individual bulk grains are obtained. One sample is oriented with the in situ tensile axis parallel to the pre-deformation axis...

  1. Women's Career Development at the Glass Ceiling.

    Science.gov (United States)

    Inman, Pamela L.

    1998-01-01

    For women, success in shattering the glass ceiling lies not in adapting to a male workplace culture but in using career strategies such as self-knowledge, multiple mentors, integration of body and soul, and fluid, customized careers. (SK)

  2. Diversity, culture and the glass ceiling.

    Science.gov (United States)

    Wilson, Eleanor

    2014-01-01

    A reference to the term, the glass ceiling, has come to embody more than gender equality among women and men. Today the term embraces the quest of all minorities and their journey towards equality in the workplace. The purpose of this article is to bring attention to the subject of diversity, culture, and the glass ceiling. The article will discuss the history of the glass ceiling and how its broadened meaning is relevant in today's workplace. It will also provide statistics showing how diversity and culture are lacking among the top echelon of today's executives, the barriers faced by minorities as they journey towards executive leadership, and how to overcome these barriers to truly shatter the glass ceiling.

  3. An Economic Theory of the Glass Ceiling

    OpenAIRE

    Paul A. Grout; In-Uck Park; Silvia Sonderegger

    2007-01-01

    The glass ceiling is one of the most controversial and emotive aspects of employment in organisations. This paper provides a model of the glass ceiling that exhibits the following features that are frequently thought to characterise the problem: (i) there is a lower number of female employees in higher positions, (ii) women have to work harder than men to obtain equivalent jobs, (iii) women are then paid less than men when promoted, and (iv) some organisations are more female friendly than ot...

  4. The perception of the glass ceiling phenomenon

    OpenAIRE

    2012-01-01

    M.B.A. Barriers that hinder career advancement of women are both complex and varied. They have become top priority for organizations and the government. The "glass ceiling" is a term that symbolizes a variety of barriers that prevent individuals from advancing up the corporate hierarchy. Although many women hold management positions, few have made the breakthrough to toplevel positions. To determine what conditions are required for women to break the glass ceiling and attain management pos...

  5. 48 CFR 452.216-74 - Ceiling Price.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Ceiling Price. 452.216-74... SOLICITATION PROVISIONS AND CONTRACT CLAUSES Texts of Provisions and Clauses 452.216-74 Ceiling Price. As prescribed in 416.670, insert the following clause: Ceiling Price (FEB 1988) The ceiling price of this...

  6. 16 CFR 305.13 - Labeling for ceiling fans.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Labeling for ceiling fans. 305.13 Section... Disclosures § 305.13 Labeling for ceiling fans. (a) Ceiling fans—(1) Content. Any covered product that is a ceiling fan shall be labeled clearly and conspicuously on the principal display panel with the following...

  7. A measurement by BOOMERANG of multiple peaks in the angular power spectrum of the cosmic microwave background

    Science.gov (United States)

    Netterfield, C. B.; Ade, P. A. R.; Bock, J. J.; Bond, J. R.; Borrill, J.; Boscaleri, A.; Coble, K.; Contaldi, C. R.; Crill, B. P.; Bernardis, P. de; hide

    2001-01-01

    This paper presents a measurement of the angular power spectrum of the Cosmic Microwave Background from l = 75 to l = 1025 (10' to 5 degrees) from a combined analysis of four 150 GHz channels in the BOOMERANG experiment. The spectrum contains multiple peaks and minima, as predicted by standard adiabatic-inflationary models in which the primordial plasma undergoes acoustic oscillations.

  8. Changes in Peak Airflow Measurement During Maximal Cough After Vocal Fold Augmentation in Patients With Glottic Insufficiency.

    Science.gov (United States)

    Dion, Gregory R; Achlatis, Efstratios; Teng, Stephanie; Fang, Yixin; Persky, Michael; Branski, Ryan C; Amin, Milan R

    2017-11-01

    Compromised cough effectiveness is correlated with dysphagia and aspiration. Glottic insufficiency likely yields decreased cough strength and effectiveness. Although vocal fold augmentation favorably affects voice and likely improves cough strength, few data exist to support this hypothesis. To assess whether vocal fold augmentation improves peak airflow measurements during maximal-effort cough following augmentation. This case series study was conducted in a tertiary, academic laryngology clinic. Participants included 14 consecutive individuals with glottic insufficiency due to vocal fold paralysis, which was diagnosed via videostrobolaryngoscopy as a component of routine clinical examination. All participants who chose to proceed with augmentation were considered for the study whether office-based or operative augmentation was planned. Postaugmentation data were collected only at the first follow-up visit, which was targeted for 14 days after augmentation but varied on the basis of participant availability. Data were collected from June 5, 2014, to October 1, 2015. Data analysis took place between October 2, 2015, and March 3, 2017. Peak airflow during maximal volitional cough was quantified before and after vocal fold augmentation. Participants performed maximal coughs, and peak expiratory flow during the maximal cough was captured according to American Thoracic Society guidelines. Among the 14 participants (7 men and 7 women), the mean (SD) age was 62 (18) years. Three types of injectable material were used for vocal fold augmentation: carboxymethylcellulose in 5 patients, hyaluronic acid in 5, and calcium hydroxylapatite in 4. Following augmentation, cough strength increased in 11 participants and decreased cough strength was observed in 3. Peak airflow measurements during maximal cough varied from a decrease of 40 L/min to an increase of 150 L/min following augmentation. When preaugmentation and postaugmentation peak airflow measurements were compared, the

  9. Comparison of equilibrium radionuclide and contrast angiographic measurements of left ventricular peak ejection and filling rates and their time intervals

    Energy Technology Data Exchange (ETDEWEB)

    Sugrue, D.D.; Dickie, S.; Newman, H.; Myers, M.J.; Lavender, J.P.; McKenna, W.J. (Royal Postgraduate Medical School, London (UK))

    1984-10-01

    A comparison has been made of the equilibrium radionuclide and contrast angiographic estimates of normalized peak rates of ejection (PER) and filling (PFR) and their time intervals in twenty-one patients with cardiac disorders. Contrast angiographic and radionuclide measurements of left ventricular ejection fraction (LVEF), PER and PFR correlated well but time intervals correlated poorly. Mean values for radionuclide LVEF, PER and PFR were significantly lower and radionuclide time intervals were significantly longer compared to contrast angiography measurements.

  10. Circuit designs for measuring reactor period, peak power, and pulse fluence on TRIGA and other pulse reactor

    International Nuclear Information System (INIS)

    Meyer, R.D.; Thome, F.V.; Williams, R.L.

    1976-01-01

    Inexpensive circuits for use in evaluating reactor pulse prompt period, peak power, and pulse fluence (NVT) are presented. In addition to low cost, these circuits are easily assembled and calibrated and operate with a high degree of accuracy. The positive period measuring system has been used in evaluating reactivity additions as small as 5 cents (with an accuracy of ±0.1 cents) and as large as $4.50 (accuracy ±2 cents). Reactor peak power is measured digitally with a system accuracy of ±0.04% of a 10 Volt input (±4 mV). The NVT circuit measures over a 2-1/2 decade range, has 3 place resolution and an accuracy of better than 1%. (author)

  11. Peak radiated power measurement of the DOE Mark II container tag with integrated ST-676 sensor radio frequency identification device.

    Energy Technology Data Exchange (ETDEWEB)

    Jursich, Mark

    2010-04-01

    The total peak radiated power of the Department of Energy Mark II container tag was measured in the electromagnetic reverberation chamber facility at Sandia National Laboratories. The tag's radio frequency content was also evaluated for possible emissions outside the intentional transmit frequency band. No spurious emissions of any significance were found, and the radiated power conformed to the manufacturer's specifications.

  12. Predicting Extubation Outcome by Cough Peak Flow Measured Using a Built-in Ventilator Flow Meter.

    Science.gov (United States)

    Gobert, Florent; Yonis, Hodane; Tapponnier, Romain; Fernandez, Raul; Labaune, Marie-Aude; Burle, Jean-François; Barbier, Jack; Vincent, Bernard; Cleyet, Maria; Richard, Jean-Christophe; Guérin, Claude

    2017-12-01

    Successful weaning from mechanical ventilation depends on the patient's ability to cough efficiently. Cough peak flow (CPF) could predict extubation success using a dedicated flow meter but required patient disconnection. We aimed to predict extubation outcome using an overall model, including cough performance assessed by a ventilator flow meter. This was a prospective observational study conducted from November 2014 to October 2015. Before and after a spontaneous breathing trial, subjects were encouraged to cough as strongly as possible before freezing the ventilator screen to assess CPF and tidal volume (V T ) in the preceding inspiration. Early extubation success rate was defined as the proportion of subjects not re-intubated 48 h after extubation. Diagnostic performance of CPF and V T was assessed by using the area under the curve of the receiver operating characteristic curve. Cut-off values for CPF and V T were defined according to median values and used to describe the performance of a predictive test combining them with risk factors of early extubation failure. Among 673 subjects admitted, 92 had a cough assessment before extubation. For the 81 subjects with early extubation success, the median CPF was -67.7 L/min, and median V T was 0.646 L. For the 11 subjects with early extubation failure, the median CPF was -57.3 L/min, and median V T was 0.448 L. Area under the curve was 0.61 (95% CI 0.37-0.83) for CPF and 0.64 (95% CI 0.42-0.84) for CPF/V T combined. After dichotomization (CPF 0.55 L), there was a synergistic effect to predict early extubation success ( P meter of an ICU ventilator was able to predict extubation success and to build a composite score to predict extubation failure. The results were close to that found in previous studies that used a dedicated flow meter. This could help to identify high-risk subjects to prevent extubation failure. (ClinicalTrials.gov registration NCT02847221.). Copyright © 2017 by Daedalus Enterprises.

  13. IR Camera Validation of IGBT Junction Temperature Measurement via Peak Gate Current

    DEFF Research Database (Denmark)

    Baker, Nick; Dupont, Laurent; Munk-Nielsen, Stig

    2017-01-01

    partial bond-wire lift-off. Results are also compared with a traditional electrical temperature measurement method: the voltage drop under low current (VCE(low)). In all cases, the IGPeak method is found to provide a temperature slightly overestimating the temperature of the gate pad. Consequently, both...... the gate pad position and chip temperature distribution influence whether the measurement is representative of the mean junction temperature. These results remain consistent after chips are degraded through bondwire lift-off. In a paralleled IGBT configuration with non-negligible temperature disequilibrium...

  14. Item analysis of single-peaked response data : the psychometric evaluation of bipolar measurement scales

    NARCIS (Netherlands)

    Polak, Maaike Geertruida

    2011-01-01

    The thesis explains the fundamental difference between unipolar and bipolar measurement scales for psychological characteristics. We explore the use of correspondence analysis (CA), a technique that is similar to principal component analysis and is available in SAS and SPSS, to select items that

  15. Thin-film thickness measurement using x-ray peak ratioing in the scanning electron microscope

    International Nuclear Information System (INIS)

    Elliott, N.E.; Anderson, W.E.; Archuleta, T.A.; Stupin, D.M.

    1981-01-01

    The procedure used to measure laser target film thickness using a scanning electron microscope is summarized. This method is generally applicable to any coating on any substrate as long as the electron energy is sufficient to penetrate the coating and the substrate produces an x-ray signal which can pass back through the coating and be detected

  16. Leco. Thermo-active Ceilings & Free Cooling. Using free cooling in combination with thermo-active ceilings for integrated heating and cooling

    OpenAIRE

    Murphy, Mark Allen

    2010-01-01

    The largest potential for decreasing green house gas emissions, and therewith mitigating the effects of global climate change, comes from improving energy efficiency. Through the integration of heating and cooling systems into building elements, such as the thermo-active ceiling, improvements in energy efficiency can be achieved. Utilizing thermal mass to buffer temperature variations and to level out peak loads reduces the instantaneous power demands and enables traditional cooling e...

  17. Leco. Thermo-active Ceilings & Free Cooling. Using free cooling in combination with thermo-active ceilings for integrated heating and cooling

    OpenAIRE

    Murphy, Mark Allen

    2010-01-01

    - The largest potential for decreasing green house gas emissions, and therewith mitigating the effects of global climate change, comes from improving energy efficiency. Through the integration of heating and cooling systems into building elements, such as the thermo-active ceiling, improvements in energy efficiency can be achieved. Utilizing thermal mass to buffer temperature variations and to level out peak loads reduces the instantaneous power demands and enables traditional cool...

  18. In pursuit of peak animal welfare; the need to prioritize the meaningful over the measurable.

    Science.gov (United States)

    Veasey, Jake S

    2017-12-01

    Despite the diversity of animal welfare definitions, most recognise the centrality of the feelings of animals which are currently impossible to measure directly. As a result, animal welfare assessment is heavily reliant upon the indirect measurement of factors that either affect what animals feel, or are effected by how they feel. Physiological and health orientated measures have emerged as popular metrics for assessing welfare because they are quantifiable, can effect and be affected by how animals feel and have merits regardless of their relationship to the feelings of animals. However, their popularity in animal welfare assessment has led to them having a disproportionate influence on animal management to the detriment of animal welfare in numerous instances. Here, the case is made that a tension exists between management that prioritizes aspects of care reflecting popular animal welfare metrics such as those relating to physical health, and management that emphasizes psychological wellbeing. By re-examining the relative merits of physical and psychological priorities in animal management, an alternate animal welfare paradigm emerges less tied to traditional welfare metrics. This paradigm theorizes about the possibility for an optimal animal welfare state to exist where managed animal populations provided essential psychological outlets but protected from key physical stressors routinely experienced in the wild, might experience higher levels of welfare than wild populations would routinely experience. The proposition that optimal animal welfare could theoretically be achieved in well managed and well designed captive environments challenges a widely held ethical perspective that captivity is inherently bad for animal welfare. © 2017 Wiley Periodicals, Inc.

  19. Refractory black carbon at the Whistler Peak High Elevation Research Site - Measurements and simulations

    Science.gov (United States)

    Hanna, Sarah J.; Xu, Jun-Wei; Schroder, Jason C.; Wang, Qiaoqiao; McMeeking, Gavin R.; Hayden, Katherine; Leaitch, W. Richard; Macdonald, AnneMarie; von Salzen, Knut; Martin, Randall V.; Bertram, Allan K.

    2018-05-01

    Measurements of black carbon at remote and high altitude locations provide an important constraint for models. Here we present six months of refractory black carbon (rBC) data collected in July-August of 2009, June-July of 2010, and April-May of 2012 using a single particle soot photometer (SP2) at the remote Whistler High Elevation Research Site in the Coast Mountains of British Columbia (50.06°N, 122.96°W, 2182 m a.m.s.l). In order to reduce regional boundary layer influences, only measurements collected during the night (2000-0800 PST) were considered. Times impacted by local biomass burning were removed from the data set, as were periods of in-cloud sampling. Back trajectories and back trajectory cluster analysis were used to classify the sampled air masses as Southern Pacific, Northern Pacific, Western Pacific/Asian, or Northern Canadian in origin. The largest rBC mass median diameter (182 nm) was seen for air masses in the Southern Pacific cluster, and the smallest (156 nm) was seen for air masses in the Western Pacific/Asian cluster. Considering all the clusters, the median mass concentration of rBC was 25.0 ± 7.6 ng/m3-STP. The Northern Pacific, Southern Pacific, Western Pacific/Asian, and Northern Canada clusters had median mass concentrations of 25.0 ± 7.6, 21.3 ± 6.9, 25.0 ± 7.9, and 40.6 ± 12.9 ng/m3-STP, respectively. We compared these measurements with simulations from the global chemical transport model GEOS-Chem. The default GEOS-Chem simulations overestimated the median rBC mass concentrations for the different clusters by a factor of 1.2-2.2. The largest difference was observed for the Northern Pacific cluster (factor of 2.2) and the smallest difference was observed for the Northern Canada cluster (factor of 1.2). A sensitivity simulation that excluded Vancouver emissions still overestimated the median rBC mass concentrations for the different clusters by a factor of 1.1-2.0. After implementation of a revised wet scavenging scheme, the

  20. Recoil polarization measurements in $\\pi^{0}$ electroproduction at the peak of the Delta (1232)

    CERN Document Server

    Sarty, A J

    2001-01-01

    This talk presents a status report, along with some preliminary/on line results, from the Thomas Jefferson National Accelerator Facility (JLab) experiment E91011 which was performed in Hall A at JLab during the summer of 2000. The experiment measured angular distributions for the differential cross section and recoil proton polarizations in the reaction p(e, e'p) pi /sup 0/. Kinematics were chosen to be centered at a CMS energy of W=1232 MeV, and a squared four momentum transfer of Q/sup 2/=1.0 (GeV/c)/sup 2/. The primary objectives of the experiment are to isolate contributions from the resonant quadrupole N to Delta , multipole S/sub 1+/, and to clarify the role of other, small nonresonant multipole contributions to the reaction. Details of the experiment itself will be given, along with sample spectra illustrating the quality and coverage of the data obtained. (10 refs) .

  1. Neutron peak velocity measurements at the National Ignition Facility (NIF) using novel quartz detectors

    Science.gov (United States)

    Grim, Gary; Eckart, Mark; Hartouni, Edward; Hatarik, Robert; Moore, Alastair; Root, Jaben; Sayre, Daniel; Schlossberg, David; Waltz, Cory

    2017-10-01

    In mid-2017 the NIF implemented quartz based neutron time-of-flight (nToF) detectors which have a faster and narrower impulse response function (IRF) relative to traditional scintillator detectors. In this presentation we report on comparisons between fusion neutron first moments as measured by quartz and scintillator based detectors using DT layered implosions at the NIF. We report on the change in precision presaged by the quartz converter and quantify the change in both in shot, line-of-site velocity variability. as well as, shot-to-shot variation. Work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract DE-AC52-07NA27344. LLNL-ABS-734511-DRAFT.

  2. Measurement and Analysis of Activation Induced in Lanthanum, Erbium and Tantalum by Fusion Peak Neutrons

    International Nuclear Information System (INIS)

    Klix, A.; Eichin, R.; Freiesleben, H.; Schomburg, K.; Seidel, K.; Unholzer, S.; Forrest, R.A.

    2006-01-01

    The large fluxes of neutrons in the materials of a fusion device during operation produce activation that is relevant to operational safety and decommissioning. Nuclides with a broad range of half-lives have to be included in the corresponding analyses. The activity with decay times ranging from the order of magnitude of minutes to weeks is of interest with respect to heat production and shut-down dose rates, whereas the long-term activity determines the waste management. The activity is mainly produced by two components of the neutron flux spectrum, by thermal neutrons and by the 14-MeV D-T fusion neutrons. Analyses of the material activation rely on calculations with inventory codes and libraries containing activation and decay data. To gain trust in the results of such calculations data and codes have to be validated experimentally. In the present work, the European Activation System (EASY, inventory code FISPACT and data library EAF) was tested in benchmark experiments on Lanthanum, Erbium and Tantalum. They are constituents of fusion reactor structural materials such as EUROFER and insulating coatings for liquid breeder systems. Small samples of the materials were irradiated in a D-T neutron field. The gamma-radioactivity following irradiation was measured several times during decay and nuclide activities were derived. For each of the measured activities the corresponding value was calculated with EASY, and the calculated-to-experimental ratios (C/E) were determined. The nuclear reactions producing the activities were also analysed. The C/E ratios obtained for the individual activities will be used for discussing the activation performance and the contact dose rate of the materials at fusion power plant conditions. (author)

  3. The Real Glass Ceiling. Your Career.

    Science.gov (United States)

    Savage, Adrian

    2002-01-01

    There is a powerful and common glass ceiling (barrier that prevents capable employees from being promoted) that affects men as much as women. Between middle management and the executive level, corporate culture shifts to one based on power and a worker must play by new rules even if these have never been explained. (JOW)

  4. Ouch! Or ESL and the Glass Ceiling.

    Science.gov (United States)

    Migliacci, Naomi

    The realities of the glass ceiling, which prevents qualified women, minorities, and many English-as-a-Second-Language (ESL) students from advancement and promotion, are rarely discussed in English for Special Purposes (ESP)/ESL programs and courses. This paper explores the barriers to success, focusing on the sociolinguistic factors of verbal and…

  5. Glass Ceiling for Women in Higher Education.

    Science.gov (United States)

    Schedler, Petra; Glastra, Folke; Hake, Barry

    2003-01-01

    Discusses the place of women in higher education in the Netherlands. Suggests that it is not a question of numbers but of orientation, field, and the glass ceiling. Asserts that despite some improvement, higher education may be one of the last bastions against the recognition of women's worth. (Contains 42 references.) (JOW)

  6. Single peak parameters technique for simultaneous measurements: Spectrophotometric sequential injection determination of Fe(II) and Fe(III).

    Science.gov (United States)

    Kozak, J; Paluch, J; Węgrzecka, A; Kozak, M; Wieczorek, M; Kochana, J; Kościelniak, P

    2016-02-01

    Spectrophotometric sequential injection system (SI) is proposed to automate the method of simultaneous determination of Fe(II) and Fe(III) on the basis of parameters of a single peak. In the developed SI system, sample and mixture of reagents (1,10-phenanthroline and sulfosalicylic acid) are introduced into a vessel, where in an acid environment (pH≅3) appropriate compounds of Fe(II) and Fe(III) with 1,10-phenanthroline and sulfosalicylic acid are formed, respectively. Then, in turn, air, sample, EDTA and sample again, are introduced into a holding coil. After the flow reversal, a segment of air is removed from the system by an additional valve and as EDTA replaces sulfosalicylic acid forming a more stable colorless compound with Fe(III), a complex signal is registered. Measurements are performed at wavelength 530 nm. The absorbance measured at minimum of the negative peak and the area or the absorbance measured at maximum of the signal can be used as measures corresponding to Fe(II) and Fe(III) concentrations, respectively. The time of the peak registration is about 2 min. Two-component calibration has been applied to analysis. Fe(II) and Fe(III) can be determined within the concentration ranges of 0.04-4.00 and 0.1-5.00 mg L(-1), with precision less than 2.8% and 1.7% (RSD), respectively and accuracy better than 7% (RE). The detection limit is 0.04 and 0.09 mg L(-1) for Fe(II) and Fe(III), respectively. The method was applied to analysis of artesian water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Chen, Qingyan

    2017-01-01

    A novel system combining diffuse ceiling ventilation and radiant ceiling was proposed recently, with the aim of providing energy efficient and comfort environment to office buildings. Designing of such a system is challenging because of complex interactions between the two subsystems and a large ......-uniformity air distribution and further led to the draught problem in the occupied zone. This system was recommended to apply in the small offices instead of large, open spaces....

  8. 48 CFR 1352.216-77 - Ceiling price.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Ceiling price. 1352.216-77... SOLICITATION PROVISIONS AND CONTRACT CLAUSES Text of Provisions and Clauses 1352.216-77 Ceiling price. As prescribed in 48 CFR 1316.601-70 and 1316.602-70, insert the following clause: Ceiling Price (APR 2010) The...

  9. Experimental study of diffuse ceiling ventilation in classroom

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Terkildsen, Søren

    Diffuse ceiling ventilation is a novel air distribution device that combines the suspended acoustic ceiling with ventilation supply. A diffuse ceiling distributes the supply air above the acoustic tiles and has proven performance in laboratory experiments. To study the performance in real conditi...

  10. Validation of an assay for quantification of free normetanephrine, metanephrine and methoxytyramine in plasma by high performance liquid chromatography with coulometric detection: Comparison of peak-area vs. peak-height measurements.

    Science.gov (United States)

    Nieć, Dawid; Kunicki, Paweł K

    2015-10-01

    Measurements of plasma concentrations of free normetanephrine (NMN), metanephrine (MN) and methoxytyramine (MTY) constitute the most diagnostically accurate screening test for pheochromocytomas and paragangliomas. The aim of this article is to present the results from a validation of an analytical method utilizing high performance liquid chromatography with coulometric detection (HPLC-CD) for quantifying plasma free NMN, MN and MTY. Additionally, peak integration by height and area and the use of one calibration curve for all batches or individual calibration curve for each batch of samples was explored as to determine the optimal approach with regard to accuracy and precision. The method was validated using charcoal stripped plasma spiked with solutions of NMN, MN, MTY and internal standard (4-hydroxy-3-methoxybenzylamine) with the exception of selectivity which was evaluated by analysis of real plasma samples. Calibration curve performance, accuracy, precision and recovery were determined following both peak-area and peak-height measurements and the obtained results were compared. The most accurate and precise method of calibration was evaluated by analyzing quality control samples at three concentration levels in 30 analytical runs. The detector response was linear over the entire tested concentration range from 10 to 2000pg/mL with R(2)≥0.9988. The LLOQ was 10pg/mL for each analyte of interest. To improve accuracy for measurements at low concentrations, a weighted (1/amount) linear regression model was employed, which resulted in inaccuracies of -2.48 to 9.78% and 0.22 to 7.81% following peak-area and peak-height integration, respectively. The imprecisions ranged from 1.07 to 15.45% and from 0.70 to 11.65% for peak-area and peak-height measurements, respectively. The optimal approach to calibration was the one utilizing an individual calibration curve for each batch of samples and peak-height measurements. It was characterized by inaccuracies ranging from -3

  11. Calibration of HPGe detector for in situ measurements of 137Cs in soil by 'peak to valley' method

    International Nuclear Information System (INIS)

    Fueloep, M.

    2000-01-01

    The contamination of soil with gamma-ray emitters can be measured in two ways: soil sampling method and in situ spectrometry of the ambient gamma-ray radiation. The conventional soil sampling method has two disadvantages: samples may not be representative for a large areas and determination of the depth distribution of radionuclide requires the measurement of several samples taken from different depths. In situ measurement of a radionuclide activity in soil is more sensitive and provides more representative data than data obtained by soil sample collection and subsequent laboratory analysis. In emergency situations time to assess the contamination is critical. For rapid assessment of the deposited activity direct measurement of ambient gamma-ray radiation are used. In order to obtain accurate measurements of radionuclides in the soil, the detector should be placed on relatively even and open terrain. It is our customary practice to place the detector 1 m above the soil surface. At this height, a tripod-mounted detector can be handled easily and still provide a radius of view for gamma emitting sources out to about 10 m. The 'field of view' actually varies, being somewhat larger for higher sources. Depending upon source energy, the detector effectively sees down to a depth of 15-30 cm. Commonly used method for field gamma spectrometry is method by Beck (1). The most important disadvantages of in situ spectrometry by Beck are that the accuracy of the analysis depends on a separate knowledge of the radioactivity distribution with soil depth. This information can be obtained by calculations using data from in situ measurements and energy dependence of absorption and scattering of photons in soil and track length distribution of photons in soil (2). A method of in situ measurements of 137 Cs in soil where radionuclide distribution in soil profile is calculated by unfolding of detector responses in the full energy peak net area at 0.662 MeV and in the valley under the

  12. 78 FR 25626 - Energy Conservation Program for Consumer Products: Energy Conservation Standards for Ceiling Fans...

    Science.gov (United States)

    2013-05-02

    ... Conservation Program for Consumer Products: Energy Conservation Standards for Ceiling Fans and Ceiling Fan... for residential ceiling fans and ceiling fan light kits in the Federal Register. This document... other aspect of the rulemaking for ceiling fans and ceiling fan light kits. The comment period is...

  13. Surface potential measurement of insulators in negative-ion implantation by secondary electron energy-peak shift

    International Nuclear Information System (INIS)

    Nagumo, Shoji; Toyota, Yoshitaka; Tsuji, Hiroshi; Gotoh, Yasuhito; Ishikawa, Junzo; Sakai, Shigeki; Tanjyo, Masayasu; Matsuda, Kohji.

    1993-01-01

    Negative-ion implantation is expected to realize charge-up free implantation. In this article, about a way to specify surface potential of negative-ion implanted insulator by secondary-electron-energy distribution, its principle and preliminary experimental results are described. By a measuring system with retarding field type energy analyzer, energy distribution of secondary electron from insulator of Fused Quartz in negative-carbon-ion implantation was measured. As a result the peak-shift of its energy distribution resulted according with the surface potential of insulator. It was found that surface potential of insulator is negatively charged by only several volts. Thus, negative-ion implanted insulator reduced its surface charge-up potential (without any electron supply). Therefore negative-ion implantation is considered to be much more effective method than conventional positive-ion implantation. (author)

  14. WOMEN WORKFORCE LOOKING THROUGH THE GLASS CEILING

    OpenAIRE

    Sarıçiçek, Reyhan; Çopuroğlu, Filiz; Aytekin, Mehmet

    2017-01-01

    Women have begun to take part in business lifeintensively in the last century. However, despite the rapid rise in the numberof women in business world, the proportion of women among senior managers andleaders has been very low. Research on the subject demonstrates that women facedifficulties called ‘Glass Ceiling’, which cannot be seen apparently and at thesame time which is hard to overcome in order to reach the senior executivepositions. Glass ceiling refers to the difficulties that take pl...

  15. Experimental investigations of heat transfer in thermo active building systems in combination with suspended ceilings

    DEFF Research Database (Denmark)

    Alvarez, Maria Alonso; Hviid, Christian Anker; Weitzmann, Peter

    2014-01-01

    buildings to cover acoustic requirements hinders the use of TABS. To measure the reduction of the heat capacity, several experiments are performed in a room equipped with TABS in the upper deck and mixing ventilation. The heat transfer is measured for different suspended ceiling covering percentages...... that the ventilation rate has a high influence on the convective heat capacity. When the ventilation rate is increased from 1.7 h-1 to 2.9 h-1, the heat transfer coefficient increases up to 16% for the same occupancy and suspended ceiling layout.......Thermo Active Building Systems (TABS), described as radiant heating or cooling systems with pipes embedded in the building structure, represent a sustainable alternative to replace conventional systems by using source temperatures close to room temperatures. The use of suspended ceiling in office...

  16. Measurement of a Peak in the Cosmic Microwave Background Power Spectrum from the North American test flight of BOOMERANG

    CERN Document Server

    Mauskopf, P D; De Bernardis, P; Bock, J J; Borrill, J; Boscaleri, A; Crill, B P; De Gasperis, G; De Troia, G; Farese, P; Ferreira, P G; Ganga, K; Giacometti, M; Hanany, S; Hristov, V V; Iacoangeli, A; Jaffe, A H; Lange, A E; Lee, A T; Masi, S; Melchiorri, A; Melchiorri, F; Miglio, L; Montroy, T; Netterfield, C B; Pascale, E; Piacentini, F; Richards, P L; Romeo, G; Ruhl, J E; Scannapieco, E S; Scaramuzzi, F; Stompor, R; Vittorio, N

    2000-01-01

    We describe a measurement of the angular power spectrum of anisotropies in the Cosmic Microwave Background (CMB) from 0.3 degrees to ~10 degrees from the North American test flight of the BOOMERANG experiment. BOOMERANG is a balloon-borne telescope with a bolometric receiver designed to map CMB anisotropies on a Long Duration Balloon flight. During a 6-hour test flight of a prototype system in 1997, we mapped > 200 square degrees at high galactic latitudes in two bands centered at 90 and 150 GHz with a resolution of 26 and 16.6 arcmin FWHM respectively. Analysis of the maps gives a power spectrum with a peak at angular scales of ~1 degree with an amplitude ~70 uK.

  17. Measurement of a peak in the cosmic microwave background power spectrum from the North American test flight of Boomerang

    International Nuclear Information System (INIS)

    Mauskopf, P.D.; Ade, P.A.R.; Bock, J.J.; Borrill, J.; Boscaleri, A.; Crill, B.P.; Bernardis, P. de; DeGasperis, G.; De Troia, G.; Farese, P.; Ferreira, P.G.; Ganga, K.; Giacometti, M.; Hanany, S.; Hristov, V.V.; Iacoangeli, A.; Jaffe, A.H.; Lange, A.E.; Lee, A.T.; Masi, S.; Melchiorri, A.; Melchiorri, F.; Miglio, L.; Montroy, T.; Netterfield, C.B.; Pascale, E.; Piacentini, F.; Richards, P.L.; Romeo, G.; Ruhl, J.E.; Scannapieco, E.; Scaramuzzi, F.; Stompor, R.; Vittorio, N.

    1999-01-01

    We describe a measurement of the angular power spectrum of anisotrophies in the Cosmic Microwave Background (CMB) from 0.2 deg to approx. 10 deg. from the test flight of the BOOMERANG experiment. BOOMERANG is a balloon-borne telescope with a bolometric receiver designed to map CMB anisotrophies on a Long Duration Balloon flight. During a 6-hour test flight of a prototype system in 1997, we mapped > 200 square degrees at high galactic latitudes in two bands centered at 90 and 150 GHz with a resolution of 26 and 16.6 arcmin FWHM respectively. Analysis of the maps gives a power spectrum with a peak at angular scales of approx. 1 deg. with an amplitude of approx. 70-muKcmb

  18. Peak Satellite-to-Earth Data Rates Derived From Measurements of a 20 Gbps Bread-Board Modem

    Science.gov (United States)

    Landon, David G.; Simons, Rainee N.; Wintucky, Edwin G.; Sun, Jun Y.; Winn, James S.; Laraway, Stephen A.; McIntire, William K.; Metz, John L.; Smith, Francis J.

    2011-01-01

    A prototype data link using a Ka-band space qualified, high efficiency 200 W TWT amplifier and a bread-board modem emulator were created to explore the feasibility of very high speed communications in satellite-to-earth applications. Experiments were conducted using a DVB-S2-like waveform with modifications to support up to 20 Gbps through the addition of 128-Quadrature Amplitude Modulation (QAM). Limited by the bandwidth of the amplifier, a constant peak symbol rate of 3.2 Giga-symbols/sec was selected and the modulation order was varied to explore what peak data rate might be supported by an RF link through this amplifier. Using 128-QAM, an implementation loss of 3 dB was observed at 20 Gbps, and the loss decreased as data rate or bandwidth were reduced. Building on this measured data, realistic link budget calculations were completed. Low-Earth orbit (LEO) missions based on this TWTA with reasonable hardware assumptions and antenna sizing are found to be bandwidth-limited, rather than power-limited, making the spectral efficiency of 9/10-rate encoded 128-QAM very attractive. Assuming a bandwidth allocation of 1 GHz, these computations indicate that low-Earth orbit vehicles could achieve data rates up to 5 Gbps-an order of magnitude beyond the current state-of-practice, yet still within the processing power of a current FPGA-based software-defined modem. The measured performance results and a description of the experimental setup are presented to support these conclusions.

  19. An Efficient Ceiling-view SLAM Using Relational Constraints Between Landmarks

    Directory of Open Access Journals (Sweden)

    Hyukdoo Choi

    2014-01-01

    Full Text Available In this paper, we present a new indoor 'simultaneous localization and mapping‘ (SLAM technique based on an upward-looking ceiling camera. Adapted from our previous work [17], the proposed method employs sparsely-distributed line and point landmarks in an indoor environment to aid with data association and reduce extended Kalman filter computation as compared with earlier techniques. Further, the proposed method exploits geometric relationships between the two types of landmarks to provide added information about the environment. This geometric information is measured with an upward-looking ceiling camera and is used as a constraint in Kalman filtering. The performance of the proposed ceiling-view (CV SLAM is demonstrated through simulations and experiments. The proposed method performs localization and mapping more accurately than those methods that use the two types of landmarks without taking into account their relative geometries.

  20. Theoretical basis to measure the impact of short-lasting control of an infectious disease on the epidemic peak

    Directory of Open Access Journals (Sweden)

    Omori Ryosuke

    2011-01-01

    Full Text Available Abstract Background While many pandemic preparedness plans have promoted disease control effort to lower and delay an epidemic peak, analytical methods for determining the required control effort and making statistical inferences have yet to be sought. As a first step to address this issue, we present a theoretical basis on which to assess the impact of an early intervention on the epidemic peak, employing a simple epidemic model. Methods We focus on estimating the impact of an early control effort (e.g. unsuccessful containment, assuming that the transmission rate abruptly increases when control is discontinued. We provide analytical expressions for magnitude and time of the epidemic peak, employing approximate logistic and logarithmic-form solutions for the latter. Empirical influenza data (H1N1-2009 in Japan are analyzed to estimate the effect of the summer holiday period in lowering and delaying the peak in 2009. Results Our model estimates that the epidemic peak of the 2009 pandemic was delayed for 21 days due to summer holiday. Decline in peak appears to be a nonlinear function of control-associated reduction in the reproduction number. Peak delay is shown to critically depend on the fraction of initially immune individuals. Conclusions The proposed modeling approaches offer methodological avenues to assess empirical data and to objectively estimate required control effort to lower and delay an epidemic peak. Analytical findings support a critical need to conduct population-wide serological survey as a prior requirement for estimating the time of peak.

  1. Existence of Glass Ceiling in Public Universities of Lahore (Pakistan)

    OpenAIRE

    Asifa Ilyas

    2014-01-01

    Glass ceiling is a set of unseen factors which adversely affect females upward career growth and prevent them to get to top positions. This study is meant to explore existence of glass ceiling in public universities of Lahore (Pakistan); and factors responsible for creating this glass ceiling effect. The respondents of this study are females heading different departments in their respective universities. The results of this study show that different cultural and social, family and organizatio...

  2. Seville City Hall Chapter Room ceiling decoration

    Directory of Open Access Journals (Sweden)

    Robador, M. D.

    2010-02-01

    Full Text Available The present article describes a chemical and physical study of the colour, chemical composition and mineral phases of the decorative materials in the Seville City Hall Chapter House ceiling. The findings showed that the inner most layer of material, calcite, was covered with white lead, in turn concealed under a layer of gilded bole. The ceiling underwent re-gilding, also over bole, due in all likelihood to wear on the original gold leaf. In the nineteenth century, the entire ceiling with the exception of the inscriptions was whitewashed with calcite and white lead. Silver was employed on King John I’s sword (coffer 27. Gold leaf was used to adorn the royal attributes: crowns, belts, sceptres, swords and rosary beads. The high reliefs were likewise gilded. The pigments identified on the ceiling adornments included azurite, malachite, vermilion and gas black. A lime and ground dolomite mortar was used throughout.

    El objetivo de este trabajo es el estudio de diferentes aspectos, como el color, la composición química y las fases mineralógicas presentes en los diferentes materiales que forman la ornamentación del techo de la Sala Capitular del Ayuntamiento de Sevilla, mediante métodos físicos y químicos. Nuestros resultados muestran que el dorado fue realizado sobre una capa de bol previamente depositada sobre una lámina de blanco de plomo que cubría un estrato de calcita. Posteriormente, y probablemente debido a alteraciones en el dorado original, el techo fue de nuevo dorado usando una técnica similar. En el siglo XIX, casi todo el techo, excepto las zonas con inscripciones, fue blanqueado usando una mezcla de calcita y blanco de plomo. Se empleó plata para cubrir la espada del rey Juan I (casetón 27. Finísimas láminas de oro se usaron para decorar los atributos reales: coronas, cinturones, cetros, espadas y rosarios. En diferentes partes de la decoración fueron detectados pigmentos como azurita, malaquita, bermellón y

  3. Measuring the educational impact of Promoting Environmental Awareness in Kids (PEAK): The development and implementation of a new scale

    Science.gov (United States)

    Jennifer Miller; Lindsey Brown; Eddie Hill; Amy Shellman; Ron Ramsing; Edwin. Gómez

    2012-01-01

    The Leave No Trace Center for Outdoor Ethics (LNT) is a nonprofit educational organization that teaches skills and values for recreating responsibly in the out-of-doors. LNT developed Promoting Environmental Awareness in Kids (PEAK), based on seven ethical principles. The PEAK program provides a pack that contains several interactive activities specifically designed to...

  4. 'Peak oil' or 'peak demand'?

    International Nuclear Information System (INIS)

    Chevallier, Bruno; Moncomble, Jean-Eudes; Sigonney, Pierre; Vially, Rolland; Bosseboeuf, Didier; Chateau, Bertrand

    2012-01-01

    This article reports a workshop which addressed several energy issues like the objectives and constraints of energy mix scenarios, the differences between the approaches in different countries, the cost of new technologies implemented for this purposes, how these technologies will be developed and marketed, which will be the environmental and societal acceptability of these technical choices. Different aspects and issues have been more precisely presented and discussed: the peak oil, development of shale gases and their cost (will non conventional hydrocarbons modify the peak oil and be socially accepted?), energy efficiency (its benefits, its reality in France and other countries, its position in front of the challenge of energy transition), and strategies in the transport sector (challenges for mobility, evolution towards a model of sustainable mobility)

  5. Modeling Outcomes with Floor or Ceiling Effects: An Introduction to the Tobit Model

    Science.gov (United States)

    McBee, Matthew

    2010-01-01

    In gifted education research, it is common for outcome variables to exhibit strong floor or ceiling effects due to insufficient range of measurement of many instruments when used with gifted populations. Common statistical methods (e.g., analysis of variance, linear regression) produce biased estimates when such effects are present. In practice,…

  6. Experimental Study of an Integrated System with Diffuse Ceiling Ventilation and Thermally Activated Building Constructions

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per

    . And the thermal comfort is analyzed by draught rate vertical temperature gradient and radiant temperature asymmetry. Finally the effect of plenum and diffuse ceiling is discussed. This report mainly focuses on the experiment results and discussions. Therefore, some details about the measurement are not presented...

  7. 78 FR 16443 - Energy Efficiency Program for Consumer Products: Energy Conservation Standards for Ceiling Fans...

    Science.gov (United States)

    2013-03-15

    ... Standards for Ceiling Fans and Ceiling Fan Light Kits AGENCY: Office of Energy Efficiency and Renewable... consider amending the energy conservation standards for ceiling fans and ceiling fan light kits. DOE also....gov . Follow the instructions for submitting comments. Email: CeilingFan[email protected

  8. Total peak shape analysis: detection and quantitation of concurrent fronting, tailing, and their effect on asymmetry measurements.

    Science.gov (United States)

    Wahab, M Farooq; Patel, Darshan C; Armstrong, Daniel W

    2017-08-04

    Most peak shapes obtained in separation science depart from linearity for various reasons such as thermodynamic, kinetic, or flow based effects. An indication of the nature of asymmetry often helps in problem solving e.g. in column overloading, slurry packing, buffer mismatch, and extra-column band broadening. However, existing tests for symmetry/asymmetry only indicate the skewness in excess (tail or front) and not the presence of both. Two simple graphical approaches are presented to analyze peak shapes typically observed in gas, liquid, and supercritical fluid chromatography as well as capillary electrophoresis. The derivative test relies on the symmetry of the inflection points and the maximum and minimum values of the derivative. The Gaussian test is a constrained curve fitting approach and determines the residuals. The residual pattern graphically allows the user to assess the problematic regions in a given peak, e.g., concurrent tailing or fronting, something which cannot be easily done with other current methods. The template provided in MS Excel automates this process. The total peak shape analysis extracts the peak parameters from the upper sections (>80% height) of the peak rather than the half height as is done conventionally. A number of situations are presented and the utility of this approach in solving practical problems is demonstrated. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Has the Copayment Ceiling Improved Financial Protection in the Korean National Health Insurance System? Evidence From the 2009 Policy Change

    Directory of Open Access Journals (Sweden)

    Tae-Jin Lee

    2017-11-01

    Full Text Available Objectives To relieve the financial burden faced by households, the Korean National Health Insurance (NHI system introduced a “copayment ceiling,” which evolved into a differential ceiling in 2009, with the copayment ceiling depending on patients’ income. This study aimed to examine the effect of the differential copayment ceiling on financial protection and healthcare utilization, particularly focusing on whether its effects varied across different income groups. Methods This study obtained data from the Korea Health Panel. The number of households included in the analysis was 6555 in 2008, 5859 in 2009, 5539 in 2010, and 5372 in 2011. To assess the effects of the differential copayment ceiling on utilization, out-of-pocket (OOP payments, and catastrophic payments, various random-effects models were applied. Utilization was measured as treatment days, while catastrophic payments were defined as OOP payments exceeding 10% of household income. Among the right-hand side variables were the interaction terms of the new policy with income levels, as well as a set of household characteristics. Results The differential copayment ceiling contributed to increased utilization regardless of income levels both in all patients and in cancer patients. However, the new policy did not seem to reduce significantly the incidence of catastrophic payments among cancer patients, and even increased the incidence among all patients. Conclusions The limited effect of the differential ceiling can be attributed to a high proportion of direct payments for services not covered by the NHI, as well as the relatively small number of households benefiting from the differential ceilings; these considerations warrant a better policy design.

  10. Has the Copayment Ceiling Improved Financial Protection in the Korean National Health Insurance System? Evidence From the 2009 Policy Change.

    Science.gov (United States)

    Lee, Tae-Jin; Cheong, Chelim

    2017-11-01

    To relieve the financial burden faced by households, the Korean National Health Insurance (NHI) system introduced a "copayment ceiling," which evolved into a differential ceiling in 2009, with the copayment ceiling depending on patients' income. This study aimed to examine the effect of the differential copayment ceiling on financial protection and healthcare utilization, particularly focusing on whether its effects varied across different income groups. This study obtained data from the Korea Health Panel. The number of households included in the analysis was 6555 in 2008, 5859 in 2009, 5539 in 2010, and 5372 in 2011. To assess the effects of the differential copayment ceiling on utilization, out-of-pocket (OOP) payments, and catastrophic payments, various random-effects models were applied. Utilization was measured as treatment days, while catastrophic payments were defined as OOP payments exceeding 10% of household income. Among the right-hand side variables were the interaction terms of the new policy with income levels, as well as a set of household characteristics. The differential copayment ceiling contributed to increased utilization regardless of income levels both in all patients and in cancer patients. However, the new policy did not seem to reduce significantly the incidence of catastrophic payments among cancer patients, and even increased the incidence among all patients. The limited effect of the differential ceiling can be attributed to a high proportion of direct payments for services not covered by the NHI, as well as the relatively small number of households benefiting from the differential ceilings; these considerations warrant a better policy design.

  11. METHOD FOR EVALUATING MOLD GROWTH ON CEILING TILE

    Science.gov (United States)

    A method to extract mold spores from porous ceiling tiles was developed using a masticator blender. Ceiling tiles were inoculated and analyzed using four species of mold. Statistical analysis comparing results obtained by masticator extraction and the swab method was performed. T...

  12. 48 CFR 217.7404-2 - Price ceiling.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Price ceiling. 217.7404-2 Section 217.7404-2 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM... Contract Actions 217.7404-2 Price ceiling. UCAs shall include a not-to-exceed price. ...

  13. 48 CFR 243.204-70-2 - Price ceiling.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Price ceiling. 243.204-70..., DEPARTMENT OF DEFENSE CONTRACT MANAGEMENT CONTRACT MODIFICATIONS Change Orders 243.204-70-2 Price ceiling. Unpriced change orders shall include a not-to-exceed price. [75 FR 48277, Aug. 10, 2010] ...

  14. Perceptions of the Glass Ceiling Effect in Community Colleges

    Science.gov (United States)

    Myers, Cheryl E.

    2010-01-01

    The purpose of this study was to determine the existence of a glass ceiling effect within community colleges by examining faculty, staff and administrator's perceptions of a glass ceiling as it relates to the advancement of women at their institutions. This was done by using a cross-sectional survey administered electronically to faculty, staff…

  15. Player Monitoring in Indoor Team Sports: Concurrent Validity of Inertial Measurement Units to Quantify Average and Peak Acceleration Values

    Directory of Open Access Journals (Sweden)

    Mareike Roell

    2018-02-01

    Full Text Available The increasing interest in assessing physical demands in team sports has led to the development of multiple sports related monitoring systems. Due to technical limitations, these systems primarily could be applied to outdoor sports, whereas an equivalent indoor locomotion analysis is not established yet. Technological development of inertial measurement units (IMU broadens the possibilities for player monitoring and enables the quantification of locomotor movements in indoor environments. The aim of the current study was to validate an IMU measuring by determining average and peak human acceleration under indoor conditions in team sport specific movements. Data of a single wearable tracking device including an IMU (Optimeye S5, Catapult Sports, Melbourne, Australia were compared to the results of a 3D motion analysis (MA system (Vicon Motion Systems, Oxford, UK during selected standardized movement simulations in an indoor laboratory (n = 56. A low-pass filtering method for gravity correction (LF and two sensor fusion algorithms for orientation estimation [Complementary Filter (CF, Kalman-Filter (KF] were implemented and compared with MA system data. Significant differences (p < 0.05 were found between LF and MA data but not between sensor fusion algorithms and MA. Higher precision and lower relative errors were found for CF (RMSE = 0.05; CV = 2.6% and KF (RMSE = 0.15; CV = 3.8% both compared to the LF method (RMSE = 1.14; CV = 47.6% regarding the magnitude of the resulting vector and strongly emphasize the implementation of orientation estimation to accurately describe human acceleration. Comparing both sensor fusion algorithms, CF revealed slightly lower errors than KF and additionally provided valuable information about positive and negative acceleration values in all three movement planes with moderate to good validity (CV = 3.9 – 17.8%. Compared to x- and y-axis superior results were found for the z-axis. These findings demonstrate that

  16. Costs and benefits of energy efficiency improvements in ceiling fans

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar; Sathaye, Nakul; Phadke, Amol; Letschert, Virginie [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

    2013-10-15

    Ceiling fans contribute significantly to residential electricity consumption, especially in developing countries with warm climates. The paper provides analysis of costs and benefits of several options to improve the efficiency of ceiling fans to assess the global potential for electricity savings and green house gas (GHG) emission reductions. Ceiling fan efficiency can be cost-effectively improved by at least 50% using commercially available technology. If these efficiency improvements are implemented in all ceiling fans sold by 2020, 70 terawatt hours per year could be saved and 25 million metric tons of carbon dioxide equivalent (CO2-e) emissions per year could be avoided, globally. We assess how policies and programs such as standards, labels, and financial incentives can be used to accelerate the adoption of efficient ceiling fans in order to realize potential savings.

  17. Chapter 10: Peak Demand and Time-Differentiated Energy Savings Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Stern, Frank [Navigant, Boulder, CO (United States); Spencer, Justin [Navigant, Boulder, CO (United States)

    2017-10-03

    Savings from electric energy efficiency measures and programs are often expressed in terms of annual energy and presented as kilowatt-hours per year (kWh/year). However, for a full assessment of the value of these savings, it is usually necessary to consider the measure or program's impact on peak demand as well as time-differentiated energy savings. This cross-cutting protocol describes methods for estimating the peak demand and time-differentiated energy impacts of measures implemented through energy efficiency programs.

  18. Implementation of the Peak Scaling Method for Temperature Measurement in the Laser Heated Diamond Anvil Cell at ALS Beamline 12.2.2

    Science.gov (United States)

    Kunz, M.; MacDowell, A. A.; Yan, J.; Beavers, C.; Doran, A.; Williams, Q. C.

    2016-12-01

    The laser-heated diamond anvil cell (LHDAC) is an important tool in the quest to correlate seismologically derived density and velocity profiles of the Earth with mineralogical models. Precise and accurate measurement of pressure and temperature is crucial for the LHDAC to be useful. Measuring accurate temperatures of laser-heated samples is an ongoing problem. One of the more promising approaches is the `peak-scaling method' as proposed by Kavner and Panero [2004]. This method relies on imaging the entire hot spot, rather than only the peak region onto the grating of a spectrometer. The temperature derived from the entire hotspot is an `average' temperature of the full hot spot. Combined with a monochromatic intensity map of the hot spot and a single temperature spot on this map (normally the peak temperature), a complete temperature map of the LHDAC can be derived. The crux of the method is to determine an accurate peak temperature. Using MATLAB, we derived systematic dependences of the relationship between average temperature and peak temperature as a function of peak temperature, deviations from the grey body assumption [ɛ = f(T,λ)], size and shape of hotspot, as well as the size and position of the spectral window used for spectral fitting. We find these average-to-peak deviations to be significant (5 - 25 %) and hard to control. To avoid biases introduced into the temperature map by erroneous assumptions on the peak temperature, we implemented on ALS beamline 12.2.2 an iterative way to fit a correct peak temperature based on the measured average temperature and measured monochromatic (700 nm) intensity map of the hot spot. The method calculates an average temperature by inverting the Planck equation on the intensities extracted from the monochromatic hotspot image and compares this value to the value obtained by fitting the Wien approximation to the averaged spectrum of the entire hotspot. The peak temperature is adjusted until the difference between

  19. Women in boards: Dichotomising the glass ceiling

    Directory of Open Access Journals (Sweden)

    Krambia-Kapardis, M.

    2007-01-01

    Full Text Available This paper identifies the reasons why glass ceiling and in the case of Cyprus “concrete ceiling” exists in both the private and public sectors despite enacted relevant legislation to ensure equality in work. Initially a qualitative research was carried out with the use of focus groups to identify the issues at hand. Following the results of the qualitative research, a questionnaire was prepared and distributed to the CEOs or the highest rank official of 120 organisations, 38% of those responded. This research, the first of its kind, addressed both the private and public sectors and confirms what has already been addressed in literature in other countries, namely that the main barrier hindering the career prospects of women is the family factor. In the public sector however where human intervention is eliminated women are better represented in the top-level positions.

  20. Women and Politics – The Glass Ceiling

    Directory of Open Access Journals (Sweden)

    Irina Zamfirache

    2010-03-01

    Full Text Available The role of women in modern politics is a subject that needs further insight, considering the growthin number of women that nowadays have relevant political positions on the international stage.There are studies today that emphasize the equality issue and all that is gender role related, but ourinterest is to analyze the women representation in power related positions. Due to the fastmodernization of the political environment and the rapid spreading of the feminist way of thought,several authors took interest in the gender differences in politics. The article follows some keydimensions in understanding the gender-role in politics: the glass ceiling, the role of the media indrawing the image of the woman politician, the gender affinity effect. In the end we would like topoint out the differences for men and women in exploiting the opportunities and securing the positions of power.

  1. Time-resolved measurement of emission profiles in pulsed radiofrequency glow discharge optical emission spectroscopy: Investigation of the pre-peak

    International Nuclear Information System (INIS)

    Alberts, D.; Horvath, P.; Nelis, Th.; Pereiro, R.; Bordel, N.; Michler, J.; Sanz-Medel, A.

    2010-01-01

    Radiofrequency glow discharge coupled to optical emission spectroscopy has been used in pulsed mode in order to perform a detailed study of the measured temporal emission profiles for a wide range of copper transitions. Special attention has been paid to the early emission peak (or so-called pre-peak), observed at the beginning of the emission pulse profile. The effects of the important pulse parameters such as frequency, duty cycle, pulse width and power-off time, have been studied upon the Cu pulse emission profiles. The influence of discharge parameters, such as pressure and power, was studied as well. Results have shown that the intensity observed in the pre-peak can be 10 times as large as the plateau value for resonant lines and up to 5 times in case of transitions to the metastable levels. Increasing pressure or power increased the pre-peak intensity while its appearance in time changed. The pre-peak decreased when the discharge off-time was shorter than 100 μs. According to such results, the presence of the pre-peak could be probably due to the lack of self-absorption during the first 50 μs, and not to the ignition of the plasma. Under the selected operation conditions, the use of the pre-peak emission as analytical signals increases the linearity of calibration curves for resonant lines subjected to self-absorption at high concentrations.

  2. Time-resolved measurement of emission profiles in pulsed radiofrequency glow discharge optical emission spectroscopy: Investigation of the pre-peak

    Energy Technology Data Exchange (ETDEWEB)

    Alberts, D. [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Claveria 8, 33006 Oviedo (Spain); Horvath, P. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Feuerwerkerstrasse 39, 3602 Thun (Switzerland); Nelis, Th. [LAPLACE, Universite Paul Sabatier, 118 rte de Narbonne, Bat3R2, 31062 Toulouse Cedex (France); CU Jean Francois Champollion, Place de Verdun 81012 Albi Cedex 9 (France); Pereiro, R. [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Claveria 8, 33006 Oviedo (Spain); Bordel, N. [Department of Physics, Faculty of Science, University of Oviedo, Calvo Sotelo, 33007 Oviedo (Spain); Michler, J. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Feuerwerkerstrasse 39, 3602 Thun (Switzerland); Sanz-Medel, A., E-mail: asm@uniovi.e [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Claveria 8, 33006 Oviedo (Spain)

    2010-07-15

    Radiofrequency glow discharge coupled to optical emission spectroscopy has been used in pulsed mode in order to perform a detailed study of the measured temporal emission profiles for a wide range of copper transitions. Special attention has been paid to the early emission peak (or so-called pre-peak), observed at the beginning of the emission pulse profile. The effects of the important pulse parameters such as frequency, duty cycle, pulse width and power-off time, have been studied upon the Cu pulse emission profiles. The influence of discharge parameters, such as pressure and power, was studied as well. Results have shown that the intensity observed in the pre-peak can be 10 times as large as the plateau value for resonant lines and up to 5 times in case of transitions to the metastable levels. Increasing pressure or power increased the pre-peak intensity while its appearance in time changed. The pre-peak decreased when the discharge off-time was shorter than 100 {mu}s. According to such results, the presence of the pre-peak could be probably due to the lack of self-absorption during the first 50 {mu}s, and not to the ignition of the plasma. Under the selected operation conditions, the use of the pre-peak emission as analytical signals increases the linearity of calibration curves for resonant lines subjected to self-absorption at high concentrations.

  3. Measurement of disintegration rates of small [60Co]Co sources in lead containers by the sum-peak method

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1991-01-01

    The sum-peak method has been applied to determine the disintegration rates of two small [ 60 Co]Co sources (30 and 350 kBq) in lead containers with several thickness by using a NaI(Tl) detector. The experimental results showed that the sum-peak method was perfectly effective for the determination of the disintegration rates (unrelated to the thicknesses of the containers) of the 350 kBq source. The sum-peak method was also absolutely effective for the 30 kBq source in the case of containers with thicknesses of 15 mm and less, but in the cases of those with thicknesses of 21, 27 and 33 mm, the disintegration rates were under-estimated and the deviations from the true disintegration rate increased rapidly with increasing thicknesses of the containers. We presume that the under-estimation of the disintegration rates was the result of the over-estimation of the areas under the sum peaks, caused by the interference of the γ-ray (2614 keV) emitted from the naturally occurring radionuclide 208 Tl. (author)

  4. Peak power ratio generator

    Science.gov (United States)

    Moyer, R.D.

    A peak power ratio generator is described for measuring, in combination with a conventional power meter, the peak power level of extremely narrow pulses in the gigahertz radio frequency bands. The present invention in a preferred embodiment utilizes a tunnel diode and a back diode combination in a detector circuit as the only high speed elements. The high speed tunnel diode provides a bistable signal and serves as a memory device of the input pulses for the remaining, slower components. A hybrid digital and analog loop maintains the peak power level of a reference channel at a known amount. Thus, by measuring the average power levels of the reference signal and the source signal, the peak power level of the source signal can be determined.

  5. An Improvement on the Junction Temperature Measurement of Light-Emitting Diodes by using the Peak Shift Method Compared with the Forward Voltage Method

    International Nuclear Information System (INIS)

    He Su-Ming; Wang Jin-Bin; Luo Xiang-Dong; Zhang Bo; Fu Lei; Cheng Li-Wen; Lu Wei

    2012-01-01

    The junction temperature of red, green and blue high power light emitting diodes (LEDs) is measured by using the emission peak shift method and the forward voltage method. Both the emission peak shift and the forward voltage decrease show a linear relationship relative to junction temperature. The linear coefficients of the red, green and blue LEDs for the peak shift method and the forward voltage method range from 0.03 to 0.15 nm/°C and from 1.33 to 3.59 mV/°C, respectively. Compared with the forward voltage method, the peak shift method is almost independent of bias current and sample difference. The variation of the slopes is less than 2% for the peak shift method and larger than 30% for the forward voltage method, when the LEDs are driven by different bias currents. It is indicated that the peak shift method gives better stability than the forward voltage method under different LED working conditions

  6. Assessment of Nitrogen Ceilings for Dutch Agricultural Soils to Avoid Adverse Environmental Impacts

    Directory of Open Access Journals (Sweden)

    Wim de Vries

    2001-01-01

    Full Text Available In the Netherlands, high traffic density and intensive animal husbandry have led to high emissions of reactive nitrogen (N into the environment. This leads to a series of environmental impacts, including: (1 nitrate (NO3 contamination of drinking water, (2 eutrophication of freshwater lakes, (3 acidification and biodiversity impacts on terrestrial ecosystems, (4 ozone and particle formation affecting human health, and (5 global climate change induced by emissions of N2O. Measures to control reactive N emissions were, up to now, directed towards those different environmental themes. Here we summarize the results of a study to analyse the agricultural N problem in the Netherlands in an integrated way, which means that all relevant aspects are taken into account simultaneously. A simple N balance model was developed, representing all crucial processes in the N chain, to calculate acceptable N inputs to the farm (so-called N ceiling and to the soil surface (application in the field by feed concentrates, organic manure, fertiliser, deposition, and N fixation. The N ceilings were calculated on the basis of critical limits for NO3 concentrations in groundwater, N concentrations in surface water, and ammonia (NH3 emission targets related to the protection of biodiversity of natural areas. Results show that in most parts of the Netherlands, except the western and the northern part, the N ceilings are limited by NH3 emissions, which are derived from critical N loads for nature areas, rather than limits for both ground- and surface water. On the national scale, the N ceiling ranges between 372 and 858 kton year–1 depending on the choice of critical limits. The current N import is 848 kton year–1. A decrease of nearly 60% is needed to reach the ceilings that are necessary to protect the environment against all adverse impacts of N pollution from agriculture.

  7. Parental leave and the glass ceiling in Sweden

    OpenAIRE

    Albrecht, James; Skogman Thoursie, Peter; Vroman, Susan

    2015-01-01

    In this paper, we update and extend "Is There a Glass Ceiling in Sweden?" (Albrecht et al. 2003) by documenting the extent to which the gender log wage gap across the distribution in Sweden has changed over the period 1998-2008. We then examine the Swedish glass ceiling in 2008 in more detail by documenting how it differs for white-collar versus blue-collar workers and for private- versus public-sector workers. We also examine when in the life cycle the glass ceiling effect arises and how thi...

  8. Decreasing fuel cost weight in electric utility business. ; Urged peak measures and management constitution improvement. Denki jigyo no nenryohi weight wa gensho. ; Isogareru peak taisaku to keiei taishitsu kaizen

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The electric power industry has made stable and economic power supply possible by advancing diversification in power sources and shifting the petroleum supply sources to southern countries and China. The cost constitution of the electric utility business in the fiscal year 1992 was such that the ratio of fuel cost is 15.9% against the total cost amount of 13 trillion 399.3 billion yen. As opposed, the fuel cost percent in the fiscal 1980 was 37.7%. This means that the effect of the fuel cost on the total cost has become smaller even if the fuel cost varies as a result of external factors including fluctuation in foreign exchange rates. Peaks in the power demand have been recorded in day time in high summer when air conditioning demand increases, which have been growing year after year. Expenses to maintain facilities and functions to deal with this demand increase have been increasing. The owned capital ratio in the electric power business was 15.7% in the fiscal 1992, which is by far lower than the average of whole industry of 28%. Execution of measures against the power peaks and improvement of the management constitution are the problems posed on the electric power industry. 4 figs., 1 tab.

  9. Smoke flow temperature beneath tunnel ceiling for train fire at subway station: Reduced-scale experiments and correlations

    International Nuclear Information System (INIS)

    Meng, Na; Wang, Qiang; Liu, Zhaoxia; Li, Xiao; Yang, He

    2017-01-01

    Highlights: • Reduced-scale experiments on train fire at subway station. • Smoke flow temperature beneath tunnel ceiling measured and correlated. • Effect of platform-tunnel conjunction door type on smoke temperature is clarified. - Abstract: This paper is to investigate the smoke flow temperature beneath tunnel ceiling for a train on fire stopping besides a subway station. Experiments were carried out in a reduced-scale (1:10) subway station model to study the maximum smoke temperature and the longitudinal temperature distribution beneath the tunnel ceiling by considering platform-tunnel conjunction doors of two types: the full-seal platform screen door (PSD) and the full-height safety door. For the maximum temperature beneath the tunnel ceiling, it is found to be well correlated non-dimensionally with heat release rate by a 3.65 and a 2.92 power law function for the full-seal platform screen door and the full-height safety door, respectively. For the longitudinal temperature distribution along the tunnel ceiling, it can be well correlated by an exponential function for both types of platform-tunnel conjunction doors. Concerning the effect of the door type, the maximum temperature is lower and the longitudinal temperature decays faster for full-height safety door than that for full-seal PSD. This is due to that with the full-height safety door, the effective width of the tunnel ceiling is widened, which results in more heat losses from the smoke flow to the ceiling.

  10. Trabecular bone mineral density measured by quantitative CT of the lumbar spine in children and adolescents: reference values and peak bone mass; Trabekulaere Knochendichte der Lendenwirbelsaeule bei Kindern und Jugendlichen in der quantitativen CT: Referenzwerte und Peak Bone Mass

    Energy Technology Data Exchange (ETDEWEB)

    Berthold, L.D.; Alzen, G. [Kinderradiologie, Zentrum fuer Radiologie, Universitaetsklinikum Giessen und Marburg GmbH, Standort Giessen (Germany); Haras, G. [Siemens AG, Medical Solutions, Forchheim (Germany); Mann, M. [AG Medizinische Statistik, Universitaetsklinikum Giessen und Marburg GmbH, Standort Giessen (Germany)

    2006-12-15

    Purpose: The aim of this study was to assess bone density values in the trabecular substance of the lumbar vertebral column in children and young adults in Germany from infancy to the age of peak bone mass. Materials and Methods: We performed quantiative computed tomography (QCT) on the first lumbar vertebra in 28 children and adolescents without diseases that may influence bone metabolism (15 boys, 13 girls, mean ages 11 and 8 years, respectively). We also measured 17 healthy young adults (9 men, 8 women, mean ages 20 and 21 years). We used a Somatom Balance Scanner (Siemens, Erlangen) and the Siemens Osteo software. Scan parameters: Slice thickness 1 cm, 80 kV, 81 or 114 mAs. We measured the trabecular bone density and the area and height of the vertebra and calculated the volume and content of calcium hydroxyapatite (Ca-HA) in the trabecular substance of the first lumbar vertebra. Results: Prepubertal boys had a mean bone density of 148.5 (median [med] 150.1, standard deviation [SD] 15.4) mg/Ca-HA per ml bone, and prepubertal girls had a mean density of 149.5 (med 150.8, SD 23.5) mg/ml. We did not observe a difference between prepubertal boys and girls. After puberty there was a significant difference (p<0.001) between males and females: Mean density (male) 158.0, med 162.5, SD 24.0 mg/ml, mean density (female) 191.2, med 191.3, SD 17.7 mg/ml. The Ca-HA content in the trabecular bone of the first lumbar vertebra was 1.1 (med 1.1, SD 0.5) g for prepubertal boys and 1.1 (0.9, 0.4) g for prepubertal girls. For post-pubertal males, the mean Ca-HA content was 3.5 g, med 3.5 SD 0.5 g, and for post-pubertal females, the mean content was 2.8, med 2.7, SD 0.4 g. Conclusion: The normal trabecular bone mineral density is 150 mg/ml with a standard deviation of 20 mg/ml independent of age or gender until the beginning of puberty. Peak bone mass (bone mineral content) in the trabecular substance of the lumbar vertebral column is higher in males than in females, and peak bone

  11. Control of the dew point for refreshing ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Abrach, R.; Nitz, T.

    1996-03-01

    The functioning of a refreshing ceiling, delivered in water, needs a global regulation which must take in consideration, the local, the building and its environment. Then efficiency and energy and investments economy are optimized. 11 figs., 3 tabs.

  12. Multiprocessor Priority Ceiling Emulation for Safety-Critical Java

    DEFF Research Database (Denmark)

    Strøm, Torur Biskopstø; Schoeberl, Martin

    2015-01-01

    Priority ceiling emulation has preferable properties on uniprocessor systems, such as avoiding priority inversion and being deadlock free. This has made it a popular locking protocol. According to the safety-critical Java specication, priority ceiling emulation is a requirement for implementations....... However, implementing the protocol for multiprocessor systemsis more complex so implementations might perform worse than non-preemptive implementations. In this paper we compare two multiprocessor lock implementations with hardware support for the Java optimized processor: non-preemptive locking...

  13. Analisa Persepsi Glass Ceiling Pada Grup Hotel Accor Di Surabaya

    OpenAIRE

    Hariono, Ardhi Ananta Kurnia; Theios, Jefson

    2017-01-01

    Tujuan dilakukannya penelitian ini adalah untuk mengetahui persepsi karyawan perempuan akan glass ceiling pada grup hotel Accor Surabaya melalui hambatan pribadi, hambatan situasional, dan hambatan sosial. Penelitian ini di fokuskan pada kelompok umur dan status pernikahan. Metode pengumpulan data menggunakan survei kepada 50 karyawan perempuan yang mejabat pada posisi manajerial di grup Hotel Accor Surabaya. Hasil penelitian menunjukkan persepsi glass ceiling pada interval kecil. Untuk kelom...

  14. Potential Global Benefits of Improved Ceiling Fan Energy Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Sathaye, Nakul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Letschert, Virginie [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-10-31

    Ceiling fans contribute significantly to residential electricity consumption, both in an absolute sense and as a proportion of household consumption in many locations, especially in developing countries in warm climates. However, there has been little detailed assessment of the costs and benefits of efficiency improvement options for ceiling fans and the potential resulting electricity consumption and greenhouse gas (GHG) emissions reductions. We analyze the costs and benefits of several options to improve the efficiency of ceiling fans and assess the global potential for electricity savings and GHG emission reductions with more detailed assessments for India, China, and the U.S. We find that ceiling fan efficiency can be cost-effectively improved by at least 50% using commercially available technology. If these efficiency improvements are implemented in all ceiling fans sold by 2020, 70 terrawatt hours per year (TWh/year) could be saved and 25 million metric tons of carbon dioxide (CO2) emissions per year could be avoided, globally. We assess how policies and programs such as standards, labels, and financial incentives can be used to accelerate the adoption of efficient ceiling fans in order to realize this savings potential.

  15. Effects of nonlinear error correction of measurements obtained by peak flowmeter using the Wright scale to assess asthma attack severity in children

    Directory of Open Access Journals (Sweden)

    Stamatović Dragana

    2007-01-01

    Full Text Available Introduction: Monitoring of peak expiratory flow (PEF is recommended in numerous guidelines for management of asthma. Improvements in calibration methods have demonstrated the inaccuracy of original Wright scale of peak flowmeter. A new standard, EN 13826 that was applied to peak flowmeter was adopted on 1st September 2004 by some European countries. Correction of PEF readings obtained with old type devices for measurement is possible by Dr M. Miller’s original predictive equation. Objective. Assessment of PEF correction effect on the interpretation of measurement results and management decisions. Method. In children with intermittent (35 or stable persistent asthma (75 aged 6-16 years, there were performed 8393 measurements of PEF by Vitalograph normal-range peak flowmeter with traditional Wright scale. Readings were expressed as percentage of individual best values (PB before and after correction. The effect of correction was analyzed based on The British Thoracic Society guidelines for asthma attack treatment. Results. In general, correction reduced the values of PEF (p<0.01. The highest mean percentage error (20.70% in the measured values was found in the subgroup in which PB ranged between 250 and 350 l/min. Nevertheless, the interpretation of PEF after the correction in this subgroup changed in only 2.41% of measurements. The lowest mean percentage error (15.72%, and, at the same time, the highest effect of correction on measurement results interpretation (in 22.65% readings were in children with PB above 450 l/min. In 73 (66.37% subjects, the correction changed the clinical interpretation of some values of PEF after correction. In 13 (11.8% patients, some corrected values indicated the absence or a milder degree of airflow obstruction. In 27 (24.54% children, more than 10%, and in 12 (10.93%, more than 20% of the corrected readings indicated a severe degree of asthma exacerbation that needed more aggressive treatment. Conclusion

  16. The glass ceiling: A biological phenomenon.

    Science.gov (United States)

    Schulpen, Tom W J

    2017-09-01

    Many brilliant and ambitious young women lose their drive for top careers after childbirth. New maternal impulses are at odds with their original ambitions and for many mothers stress and frustration will be the result as they have to combine child care with workweeks of 60-80h to reach or remain at the top. Pregnancy hormones modify the female's brain as has been demonstrated already for decades in animals. This brain plasticity due to adult neurogenesis in the so called maternal circuitry of the limbic system is long-lasting and perhaps lifelong. In humans hormonal and neuro-imaging studies show ample evidence for fundamental and long lasting pregnancy induced brain changes, not only in the limbic system, but also in the cortical networks like theory of mind and mirror neuron system. Recent research shows pronounced and long lasting brain changes in several of these areas. It can be concluded that there exists a maternal brain that drives mother's behaviour and priorities. Research in men shows that the more fathers are involved in raising their children, the more caring behaviour they develop. Structural anatomical changes are found in neural regions involved in parental motivation. These studies show that brain plasticity in fathers is experience dependent. In Nordic countries, a policy of paid paternal leave followed by a flexible shared parental leave, stimulates fatherly behaviour. This might reduce men's eagerness for top careers, thus creating better opportunities for women. Demolition of women's glass ceiling starts with the father. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Principle, function, experiences, hybrid chilled ceilings; Prinzip, Funktion, Erfahrungen. Hybrid-Kuehldecken

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Uwe W. [Hochschule Luzern (Switzerland). Technik und Architektur

    2010-12-15

    Hybrid chilled ceilings combine a radiation chilled ceiling with thermal activations of a concrete ceiling. The activation permits the utilization of alternative and/or small cold generators for the efficient night cooling. The traditional chilled ceiling grants a speedy reaction to load variations as well as a reduction of the reverberation periods. In addition, the combination supplies a draught-free insertion of air. Beside established solutions, MWH Barcol-Air (Staefa, Switzerland) also offers project-specific hybrid chilled ceilings.

  18. Robust Event-Triggered Energy-to-Peak Filtering for Polytopic Uncertain Systems over Lossy Network with Quantized Measurements

    Directory of Open Access Journals (Sweden)

    Jidong Wang

    2016-01-01

    Full Text Available The event-triggered energy-to-peak filtering for polytopic discrete-time linear systems is studied with the consideration of lossy network and quantization error. Because of the communication imperfections from the packet dropout of lossy link, the event-triggered condition used to determine the data release instant at the event generator (EG can not be directly applied to update the filter input at the zero order holder (ZOH when performing filter performance analysis and synthesis. In order to balance such nonuniform time series between the triggered instant of EG and the updated instant of ZOH, two event-triggered conditions are defined, respectively, whereafter a worst-case bound on the number of consecutive packet losses of the transmitted data from EG is given, which marginally guarantees the effectiveness of the filter that will be designed based on the event-triggered updating condition of ZOH. Then, the filter performance analysis conditions are obtained under the assumption that the maximum number of packet losses is allowable for the worst-case bound. In what follows, a two-stage LMI-based alternative optimization approach is proposed to separately design the filter, which reduces the conservatism of the traditional linearization method of filter analysis conditions. Subsequently a codesign algorithm is developed to determine the communication and filter parameters simultaneously. Finally, an illustrative example is provided to verify the validity of the obtained results.

  19. Adoption of preventive measures during and after the 2009 influenza A (H1N1) virus pandemic peak in Spain.

    Science.gov (United States)

    Agüero, Fernando; Adell, Manel Nebot; Pérez Giménez, Anna; López Medina, María José; Garcia Continente, Xavier

    2011-09-01

    This study describes the preventive measures adopted by the Spanish population towards 2009 influenza A (H1N1) virus and their associated factors. An anonymous computer-assisted telephone interview survey was conducted in Spain in December 2009 and February 2010. Respondents were asked about their perceptions of influenza A (H1N1) virus and the preventive measures adopted. Factors associated with the adoption of preventive measures were assessed by logistic regression analyses. Out of 4892 households approached, 1627 valid responses were obtained (response rate of 33.3%). The most commonly adopted preventive measures were respiratory hygiene and hand washing. Factors independently associated with the adoption of the preventive measures recommended by the Spanish Ministry of Health were female gender, higher educational level, size of municipality of residence >50,000 inhabitants, high perceived susceptibility to infection, high perceived effectiveness of the measures and high perceived usefulness of the information provided by the government. The presence of school-aged children in household was associated with purchasing masks and hand sanitizer. In addition to demographic factors, modifiable factors such as personal beliefs and expectations play a role in the adoption of preventive measures. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Hydro turbine governor’s power control of hydroelectric unit with sloping ceiling tailrace tunnel

    Science.gov (United States)

    Fu, Liang; Wu, Changli; Tang, Weiping

    2018-02-01

    The primary frequency regulation and load regulation transient process when the hydro turbine governor is under the power mode of hydropower unit with sloping ceiling tailrace are analysed by field test and numerical simulation in this paper. A simulation method based on “three-zone model” to simulate small fluctuation transient process of the sloping ceiling tailrace is proposed. The simulation model of hydraulic turbine governor power mode is established by governor’s PLC program identification and parameter measurement, and the simulation model is verified by the test. The slow-fast-slow “three-stage regulation” method which can improve the dynamic quality of hydro turbine governor power mode is proposed. The power regulation strategy and parameters are optimized by numerical simulation, the performance of primary frequency regulation and load regulation transient process when the hydro turbine governor is under power mode are improved significantly.

  1. Above the glass ceiling? A comparison of matched samples of female and male executives.

    Science.gov (United States)

    Lyness, K S; Thompson, D E

    1997-06-01

    In this study the authors compare career and work experiences of executive women and men. Female (n = 51) and male (n = 56) financial services executives in comparable jobs were studied through archival information on organizational outcomes and career histories, and survey measures of work experiences. Similarities were found in several organizational outcomes, such as compensation, and many work attitudes. Important differences were found, however, with women having less authority, receiving fewer stock options, and having less international mobility than men. Women at the highest executive levels reported more obstacles than lower level women. The gender differences coupled with women's lower satisfaction with future career opportunities raise questions about whether women are truly above the glass ceiling or have come up against a 2nd, higher ceiling.

  2. The Locations of Ring Current Pressure Peaks: Comparison of TWINS Measurements and CIMI Simulations for the 7-10 September 2015 CIR Storm

    Science.gov (United States)

    Hill, S. C.; Edmond, J. A.; Xu, H.; Perez, J. D.; Fok, M. C. H.; Goldstein, J.; McComas, D. J.; Valek, P. W.

    2017-12-01

    The characteristics of a four day 7-10 September 2015 co-rotating interaction region (CIR) storm (min. SYM/H ≤ -110 nT) are categorized by storm phase. Ion distributions of trapped particles in the ring current as measured by the Two Wide-Angle Imaging Neutral Atom Spectrometers (TWINS) are compared with the simulated ion distributions of the Comprehensive Inner Magnetosphere-Ionosphere Model (CIMI). The energetic neutral atom (ENA) images obtained by TWINS are deconvolved to extract equatorial pitch angle, energy spectra, ion pressure intensity, and ion pressure anisotropy distributions in the inner magnetosphere. CIMI, using either a self-consistent electric field or a semi-empirical electric field, simulates comparable distributions. There is good agreement between the data measured by TWINS and the different distributions produced by the self-consistent electric field and the semi-empirical electric field of CIMI. Throughout the storm the pitch angle distribution (PAD) is mostly perpendicular in both CIMI and TWINS and there is agreement between the anisotropy distributions. The locations of the ion pressure peaks seen by TWINS and by the self-consistent and semi empirical electric field parameters in CIMI are usually between dusk and midnight. On average, the self-consistent electric field in CIMI reveals ion pressure peaks closer to Earth than its semi empirical counterpart, while TWINS reports somewhat larger radial values for the ion pressure peak locations. There are also notable events throughout the storm during which the simulated observations show some characteristics that differ from those measured by TWINS. At times, there are ion pressure peaks with magnetic local time on the dayside and in the midnight to dawn region. We discuss these events in light of substorm injections indicated by fluctuating peaks in the AE index and a positive By component in the solar wind. There are also times in which there are multiple ion pressure peaks. This may

  3. Exponential Increase in Relative Biological Effectiveness Along Distal Edge of a Proton Bragg Peak as Measured by Deoxyribonucleic Acid Double-Strand Breaks

    Energy Technology Data Exchange (ETDEWEB)

    Cuaron, John J., E-mail: cuaronj@mskcc.org [Memorial Sloan Kettering Cancer Center, New York, New York (United States); Chang, Chang [Texas Center for Proton Therapy, Irving, Texas (United States); Lovelock, Michael; Higginson, Daniel S. [Memorial Sloan Kettering Cancer Center, New York, New York (United States); Mah, Dennis [Procure Proton Therapy Center, Somerset, New Jersey (United States); Cahlon, Oren; Powell, Simon [Memorial Sloan Kettering Cancer Center, New York, New York (United States)

    2016-05-01

    Purpose: To quantify the relative biological effectiveness (RBE) of the distal edge of the proton Bragg peak, using an in vitro assay of DNA double-strand breaks (DSBs). Methods and Materials: U2OS cells were irradiated within the plateau of a spread-out Bragg peak and at each millimeter position along the distal edge using a custom slide holder, allowing for simultaneous measurement of physical dose. A reference radiation signal was generated using photons. The DNA DSBs at 3 hours (to assess for early damage) and at 24 hours (to assess for residual damage and repair) after irradiation were measured using the γH2AX assay and quantified via flow cytometry. Results were confirmed with clonogenic survival assays. A detailed map of the RBE as a function of depth along the Bragg peak was generated using γH2AX measurements as a biological endpoint. Results: At 3 hours after irradiation, DNA DSBs were higher with protons at every point along the distal edge compared with samples irradiated with photons to similar doses. This effect was even more pronounced after 24 hours, indicating that the impact of DNA repair is less after proton irradiation relative to photons. The RBE demonstrated an exponential increase as a function of depth and was measured to be as high as 4.0 after 3 hours and as high as 6.0 after 24 hours. When the RBE-corrected dose was plotted as a function of depth, the peak effective dose was extended 2-3 mm beyond what would be expected with physical measurement. Conclusions: We generated a highly comprehensive map of the RBE of the distal edge of the Bragg peak, using a direct assay of DNA DSBs in vitro. Our data show that the RBE of the distal edge increases with depth and is significantly higher than previously reported estimates.

  4. Measurement of the b quark forward-backward asymmetry around the $Z^{0}$ peak using an inclusive tag

    CERN Document Server

    Abbiendi, G.; Akesson, P.F.; Alexander, G.; Allison, John; Amaral, P.; Anagnostou, G.; Anderson, K.J.; Arcelli, S.; Asai, S.; Axen, D.; Azuelos, G.; Bailey, I.; Barberio, E.; Barlow, R.J.; Batley, R.J.; Bechtle, P.; Behnke, T.; Bell, Kenneth Watson; Bell, P.J.; Bella, G.; Bellerive, A.; Benelli, G.; Bethke, S.; Biebel, O.; Bloodworth, I.J.; Boeriu, O.; Bock, P.; Bonacorsi, D.; Boutemeur, M.; Braibant, S.; Brigliadori, L.; Brown, Robert M.; Buesser, K.; Burckhart, H.J.; Campana, S.; Carnegie, R.K.; Caron, B.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Csilling, A.; Cuffiani, M.; Dado, S.; Dallavalle, G.Marco; Dallison, S.; De Roeck, A.; De Wolf, E.A.; Desch, K.; Dienes, B.; Donkers, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Elfgren, E.; Etzion, E.; Fabbri, F.; Feld, L.; Ferrari, P.; Fiedler, F.; Fleck, I.; Ford, M.; Frey, A.; Furtjes, A.; Gagnon, P.; Gary, John William; Gaycken, G.; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Giunta, Marina; Goldberg, J.; Gross, E.; Grunhaus, J.; Gruwe, M.; Gunther, P.O.; Gupta, A.; Hajdu, C.; Hamann, M.; Hanson, G.G.; Harder, K.; Harel, A.; Harin-Dirac, M.; Hauschild, M.; Hauschildt, J.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Hensel, C.; Herten, G.; Heuer, R.D.; Hill, J.C.; Hoffman, Kara Dion; Homer, R.J.; Horvath, D.; Howard, R.; Huntemeyer, P.; Igo-Kemenes, P.; Ishii, K.; Jeremie, H.; Jovanovic, P.; Junk, T.R.; Kanaya, N.; Kanzaki, J.; Karapetian, G.; Karlen, D.; Kartvelishvili, V.; Kawagoe, K.; Kawamoto, T.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kim, D.H.; Klein, K.; Klier, A.; Kluth, S.; Kobayashi, T.; Kobel, M.; Komamiya, S.; Kormos, Laura L.; Kowalewski, Robert V.; Kramer, T.; Kress, T.; Krieger, P.; von Krogh, J.; Krop, D.; Kruger, K.; Kupper, M.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Layter, J.G.; Leins, A.; Lellouch, D.; Letts, J.; Levinson, L.; Lillich, J.; Lloyd, S.L.; Loebinger, F.K.; Lu, J.; Ludwig, J.; Macpherson, A.; Mader, W.; Marcellini, S.; Marchant, T.E.; Martin, A.J.; Martin, J.P.; Masetti, G.; Mashimo, T.; Mattig, Peter; McDonald, W.J.; McKenna, J.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Mendez-Lorenzo, P.; Menges, W.; Merritt, F.S.; Mes, H.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Moed, S.; Mohr, W.; Mori, T.; Mutter, A.; Nagai, K.; Nakamura, I.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oh, A.; Okpara, A.; Oreglia, M.J.; Orito, S.; Pahl, C.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poli, B.; Polok, J.; Pooth, O.; Przybycien, M.; Quadt, A.; Rabbertz, K.; Rembser, C.; Renkel, P.; Rick, H.; Roney, J.M.; Rosati, S.; Rozen, Y.; Runge, K.; Sachs, K.; Saeki, T.; Sahr, O.; Sarkisyan, E.K.G.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schoerner-Sadenius, Thomas; Schroder, Matthias; Schumacher, M.; Schwick, C.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Shepherd-Themistocleous, C.H.; Sherwood, P.; Siroli, G.; Skuja, A.; Smith, A.M.; Sobie, R.; Soldner-Rembold, S.; Spagnolo, S.; Spano, F.; Stahl, A.; Stephens, K.; Strom, David M.; Strohmer, R.; Tarem, S.; Tasevsky, M.; Taylor, R.J.; Teuscher, R.; Thomson, M.A.; Torrence, E.; Toya, D.; Tran, P.; Trefzger, T.; Tricoli, A.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Ujvari, B.; Vachon, B.; Vollmer, C.F.; Vannerem, P.; Verzocchi, M.; Voss, H.; Vossebeld, J.; Waller, D.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wengler, T.; Wermes, N.; Wetterling, D.; Wilson, G.W.; Wilson, J.A.; Wolf, G.; Wyatt, T.R.; Yamashita, S.; Zer-Zion, D.; Zivkovic, Lidija

    2002-01-01

    The b quark forward-backward asymmetry has been measured using hadronic Z0 decays collected by the OPAL experiment at LEP. Z0 -> bbbar decays were selected using a combination of secondary vertex and lepton tags, and the sign of the b quark charge was determined using an inclusive tag based on jet, vertex and kaon charges. The results, corrected to the quark level, are: A^b_FB = 0.0582 +- 0.0153 +- 0.0012 at sqrt(s) = 89.50 GeV A^b_FB = 0.0977 +- 0.0036 +- 0.0018 at sqrt(s) = 91.26 GeV A^b_FB = 0.1221 +- 0.0123 +- 0.0025 at sqrt(s) = 92.91 GeV where the first error is statistical and the second systematic in each case. Within the framework of the Standard Model, the result is interpreted as a measurement of the effective weak mixing angle for electrons of sin2theta_W^eff,e = 0.23205 +- 0.00068.

  5. Human Response to Personalized Ventilation Combined with Chilled Ceiling

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Marcol, Bartosz

    2014-01-01

    Personalized ventilation (PV) improves inhaled air quality, because it provides fresh air to each workstation and directly to occupant’s breathing zone. Previous research was focused on combining PV with additional total volume air distribution, i.e. mixing ventilation or displacement ventilation......, the use of radiant ceiling cooling will provide operative temperature lower than the air temperature and will improve further occupants’ thermal comfort at warm environment. Therefore combining PV with chilled ceiling may be an effective way to provide thermal comfort in rooms at temperature higher than...... temperature for chilled ceiling was 15,5/16,8°C at room air temperature of 26°C and 19,5/20,6°C at 28°C. During the experiment the subjects were performing typical office tasks at workstations with computers. Exposure included also increased activity level office work for a period of 25 min...

  6. Effect of Number of Blades on Performance of Ceiling Fans

    Directory of Open Access Journals (Sweden)

    Adeeb Ehsan

    2015-01-01

    Full Text Available In this paper, the effect of number of blades on ceiling fan performance is discussed. This approach helps to satisfy tradeoff between high air flow (performance and power consumption (energy efficiency. Specifically, variation from two to six blades is considered with nonlinear forward sweep profile. Reynolds Averaged Navier-Stokes (RANS technique is used to model the flow field induced by the ceiling fan inside a generic room. The performance is gauged through response parameters namely volumetric flow rate, mass flow rate, torque and energy efficiency. The results indicate that mass and volumetric flow rates are maximized for six blade configuration and energy efficiency is maximized for two blade configuration. The study indicates the importance of tradeoff between high air flow through ceiling fan and associated energy efficiency.

  7. Breaking through the uncertainty ceiling in LA-ICP-MS U-Pb geochronology

    Science.gov (United States)

    Horstwood, M.

    2016-12-01

    Sources of systematic uncertainty associated with session-to-session bias are the dominant contributor to the 2% (2s) uncertainty ceiling that currently limits the accuracy of LA-ICP-MS U-Pb geochronology. Sources include differential downhole fractionation (LIEF), `matrix effects' and ablation volume differences, which result in irreproducibility of the same reference material across sessions. Current mitigation methods include correcting for LIEF mathematically, using matrix-matched reference materials, annealing material to reduce or eliminate radiation damage effects and tuning for robust plasma conditions. Reducing the depth and volume of ablation can also mitigate these problems and should contribute to the reduction of the uncertainty ceiling. Reducing analysed volume leads to increased detection efficiency, reduced matrix-effects, eliminates LIEF, obviates ablation rate differences and reduces the likelihood of intercepting complex growth zones with depth, thereby apparently improving material homogeneity. High detection efficiencies (% level) and low sampling volumes (20um box, 1-2um deep) can now be achieved using MC-ICP-MS such that low volume ablations should be considered part of the toolbox of methods targeted at improving the reproducibility of LA-ICP-MS U-Pb geochronology. In combination with other strategies these improvements should be feasible on any ICP platform. However, reducing the volume of analysis reduces detected counts and requires a change of analytical approach in order to mitigate this. Appropriate strategies may include the use of high efficiency cell and torch technologies and the optimisation of acquisition protocols and data handling techniques such as condensing signal peaks, using log ratios and total signal integration. The tools required to break the 2% (2s) uncertainty ceiling in LA-ICP-MS U-Pb geochronology are likely now known but require a coherent strategy and change of approach to combine their implementation and realise

  8. Glass ceiling in SMEs? Women, managerialization and performance

    OpenAIRE

    L. Songini; L. Gnan

    2012-01-01

    This article analyses the role of women in a sample of Italian small and medium sized enterprises (SMEs), both non-family and family owned businesses. We assume that the existence of a glass ceiling implies that women are not in a position to exercise an active role in the company; ownership per se does not assure the elimination of the glass ceiling, while the broader involvement of women in governance and management roles, as we may suppose in family firms, may represent a better situation ...

  9. Effect of a ceiling fan ventilation system on finishing young bulls' health, behaviour and growth performance.

    Science.gov (United States)

    Magrin, L; Brscic, M; Lora, I; Rumor, C; Tondello, L; Cozzi, G; Gottardo, F

    2017-06-01

    This research aimed at assessing the effects of a ceiling fan ventilation system on health, feeding, social behaviour and growth response of finishing young bulls fattened indoors during a mild summer season. A total of 69 Charolais young bulls were housed in six pens without any mechanical ventilation system (Control) and in six pens equipped with ceiling fans. The experimental period lasted 98 days from June until mid-September 2014. Four experimental days were considered in order to assess the effect of the ventilation system under two different microclimatic conditions: 2 alert days at monthly interval with temperature humidity index (THI) between 75 and 78, and 2 normal days with THI⩽74. Health and behaviour of the bulls were evaluated through 8-h observation sessions starting after morning feed delivery. The study was carried out during a rather cool summer with a climate average THI of 68.9 and 4 days with average THI>75. Despite these mild climate conditions, ceiling fans lowered litter moisture and acted as a preventive measure for bulls' dirtiness (odd ratio=47.9; 95% CI 19.6 to 117.4). The risk of abnormal breathing was increased for Control bulls (odd ratio=40.7; 95% CI 5.4 to 304.2). When exposed to alert THI conditions, respiration rate and panting scores increased and rumination duration dropped in Control bulls compared with bulls provided with a ceiling fan. During observations under alert THI, bulls spent less time eating, more time being inactive and consumed more water compared with normal THI conditions. Bulls' daily dry matter intake measured during the observation sessions decreased on alert compared with normal THI days (Pbehaviour (rumination, lying down and drinking water) and respiration rate, however. The lack of a significant improvement of bulls' growth response should not discourage beef farmers from using ceiling fans in indoor systems, considering the likely increase in frequency and intensity of heat waves in the planet

  10. Magnetic Field-Vector Measurements in Quiescent Prominences via the Hanle Effect: Analysis of Prominences Observed at Pic-Du-Midi and at Sacramento Peak

    Science.gov (United States)

    Bommier, V.; Leroy, J. L.; Sahal-Brechot, S.

    1985-01-01

    The Hanle effect method for magnetic field vector diagnostics has now provided results on the magnetic field strength and direction in quiescent prominences, from linear polarization measurements in the He I E sub 3 line, performed at the Pic-du-Midi and at Sacramento Peak. However, there is an inescapable ambiguity in the field vector determination: each polarization measurement provides two field vector solutions symmetrical with respect to the line-of-sight. A statistical analysis capable of solving this ambiguity was applied to the large sample of prominences observed at the Pic-du-Midi (Leroy, et al., 1984); the same method of analysis applied to the prominences observed at Sacramento Peak (Athay, et al., 1983) provides results in agreement on the most probable magnetic structure of prominences; these results are detailed. The statistical results were confirmed on favorable individual cases: for 15 prominences observed at Pic-du-Midi, the two-field vectors are pointing on the same side of the prominence, and the alpha angles are large enough with respect to the measurements and interpretation inaccuracies, so that the field polarity is derived without any ambiguity.

  11. Measurement of 235U Enrichment Using the Semi-Peak-Ratio Technique with CdZnTe Gamma-Ray Detector

    International Nuclear Information System (INIS)

    Ha, J. H.; Ko, W. I.; Lee, S. Y.; Song, D. Y.; Kim, H. D.; Yang, M. S.

    2001-01-01

    In uranium enrichment plants and nuclear fuel fabrication facilities, exact measurement of fissile isotope enrichment of Uranium is required for material accounting in international safeguards inspection as well as process quality control. The purpose of this study was to develop a simple measurement system which can portably be used at nuclear fuel fabrication plants especially dealing with low enriched uranium. For this purpose, a small size CZT (CdZnTe) detector was used, and the detector performance in low uranium gamma/X-rays energy range was investigated by use of various enriched uranium oxide samples. New enrichment measurement technique and analysis method for low enriched uranium oxide, so-called, 'semi-peak ratio technique' was developed. The newly developed method was considered as an alternative technique for the low enrichment and would be useful to account nuclear material in safeguarding activity at nuclear fuel fabrication facility

  12. A Modest Manifesto for Shattering the Glass Ceiling.

    Science.gov (United States)

    Meyerson, Debra E.; Fletcher, Joyce K.

    2000-01-01

    Approaches to the glass ceiling--encouraging women to adopt "masculine" attributes, accommodating women's unique needs, or celebrating women's differences--have shortcomings. A fourth approach links equity and effectiveness. "Small wins" recognizes that gender inequity is rooted in cultural patterns and uses small initiatives…

  13. Breaking the Educational Glass Ceiling: An Interview with Harry Lenderman

    Science.gov (United States)

    Lenderman, Harry; Sandelands, Eric

    2005-01-01

    Purpose - To examine the role that corporations can and are playing in removing restrictions to a college or university education for their employees - the educational glass ceiling. Design/methodology/approach - An interview format is used with an experienced academic, and learning and development practitioner, drawing upon experiences and…

  14. Managers' Beliefs about the Glass Ceiling: Interpersonal and Organizational Factors

    Science.gov (United States)

    Elacqua, Tina C.; Beehr, Terry A.; Hansen, Curtiss P.; Webster, Jennica

    2009-01-01

    The glass ceiling refers to the difficulty of women trying to be promoted into the top management levels. The present study examined managers' potential explanations, implicit or explicit, for why women rarely reach the top hierarchical levels in their own organization. Among 685 managers at a large Midwestern insurance company, a model was…

  15. EVALUATION OF FUNGAL GROWTH (PENICILLIUM GLABRUM) ON A CEILING TILE

    Science.gov (United States)

    The paper gives results of a study employing static chambers to study the impact of different equilibrium relative humidities (RHs) and moisture conditions on the ability of a new ceiling tile to support fungal growth. Amplification of the mold, Penicillium glabrum, occurred at R...

  16. Breakthrough: The Career Woman's Guide to Shattering the Glass Ceiling.

    Science.gov (United States)

    Flanders, Margaret L.

    This practical guide for all working women shows the reader how to recognize the barriers likely to confront her and to find the most effective way of breaking through. Chapter 1 summarizes causes of the glass ceiling and provides pointers on recognizing which situations are likely to cause problems. Chapter 2 helps the reader to understand her…

  17. Smashing into the Glass Ceiling for Women Managers.

    Science.gov (United States)

    Veale, Camilla; Gold, Jeff

    1998-01-01

    Interviews with 10 women administrators in a British metropolitan district council revealed the glass ceiling to be a complex phenomenon reaching beyond the employment sphere. Their career progression was hindered by lack of career counseling, family-work conflicts, lack of management development for women, and particularly a managerial culture…

  18. Circumventing the Glass Ceiling: Women Executives in American State Governments.

    Science.gov (United States)

    Bullard, Angela M.; Wright, Deil S.

    1993-01-01

    Data from 1984 (n=489) and 1988 (n=658) surveys show that female executives in state government have progressed in top positions in certain types of agencies, but much progress has occurred by avoiding, not breaking, the glass ceiling. Most notable male-female differences are in party affiliation, age, interagency mobility, career progress, and…

  19. A diagnosis of discrimination. Women physicians and the glass ceiling.

    Science.gov (United States)

    Sebastian, C

    1994-01-01

    Author Christy Sebastian writes about some of the limits facing women physicians, from the glass ceiling on down. She relates the limits faced by women physicians to the gender differences--both subtle and blatant--evident in society as a whole.

  20. Measuring Your Peak Flow Rate

    Science.gov (United States)

    ... based on a person's age, height, sex and race. A standardized "normal" may be obtained from a ... Climb LUNG FORCE Walks Cycling Events Donate a Car Memorial & Honor Gifts Planned Giving Christmas Seals ABOUT ...

  1. Predicting Voice Disorder Status From Smoothed Measures of Cepstral Peak Prominence Using Praat and Analysis of Dysphonia in Speech and Voice (ADSV).

    Science.gov (United States)

    Sauder, Cara; Bretl, Michelle; Eadie, Tanya

    2017-09-01

    The purposes of this study were to (1) determine and compare the diagnostic accuracy of a single acoustic measure, smoothed cepstral peak prominence (CPPS), to predict voice disorder status from connected speech samples using two software systems: Analysis of Dysphonia in Speech and Voice (ADSV) and Praat; and (2) to determine the relationship between measures of CPPS generated from these programs. This is a retrospective cross-sectional study. Measures of CPPS were obtained from connected speech recordings of 100 subjects with voice disorders and 70 nondysphonic subjects without vocal complaints using commercially available ADSV and freely downloadable Praat software programs. Logistic regression and receiver operating characteristic (ROC) analyses were used to evaluate and compare the diagnostic accuracy of CPPS measures. Relationships between CPPS measures from the programs were determined. Results showed acceptable overall accuracy rates (75% accuracy, ADSV; 82% accuracy, Praat) and area under the ROC curves (area under the curve [AUC] = 0.81, ADSV; AUC = 0.91, Praat) for predicting voice disorder status, with slight differences in sensitivity and specificity. CPPS measures derived from Praat were uniquely predictive of disorder status above and beyond CPPS measures from ADSV (χ 2 (1) = 40.71, P disorder status using either program. Clinicians may consider using CPPS to complement clinical voice evaluation and screening protocols. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  2. Measurement of the K X-ray absorption jump factors and jump ratios of Gd, Dy, Ho and Er by attenuation of a Compton peak

    International Nuclear Information System (INIS)

    Budak, G.; Polat, R.

    2004-01-01

    The X-ray absorption jump factor and jump ratio of Gd, Dy, Ho and Er were measured with a Si(Li) detector by attenuation, with Gd, Dy, Ho and Er foil, a Compton peak produced by the scattering of the 59.5 keV Am-241 Gamma rays. Al was chosen as secondary exciter. The experimental absorption jump factors and jump ratios are compared with the theoretical estimates of WinXcom (Radiat. Phys. Chem. 60 (2001) 23), McMaster (Compilation of X-ray cross sections UCRL-50174, 1969; Sec. II. Rev. I), Broll (X-ray Spectrom 15 (1986) 271), Hubbel and Seltzer (NISTIR (1995) 5632) and Budak (Radiat. Meas. accepted for publication). The present results constitute the first measurement for this combination of energy and elements, and good agreement is obtained between experiment and theory

  3. GROWTH EVALUATION OF FUNGI (PENICILLIUM AND ASPERGILLUS SPP.) ON CEILING TILES

    Science.gov (United States)

    The paper gives results of an evaluation of the potential for fungal growth on four different ceiling tiles in static chambers. It was found that even new ceiling tiles supported fungal growth under favorable conditions. Used ceiling tiles appeared to be more susceptible to funga...

  4. An acoustical research of the undulating wooden ceiling in the Vyborg Library

    DEFF Research Database (Denmark)

    Mortensen, Bo

    2004-01-01

    Much has been written about the Undulating Ceiling at the lecture hall of the Vyborg Library. Alvar Aalto himself claimed the ceiling to be "ninety-nine per cent acoustically perfect" and the sketches showing the acoustical considerations behind the ceiling-design is often reproduced. But how did...

  5. Glass Ceiling in Academic Administration in Turkey: 1990s versus 2000s

    Science.gov (United States)

    Gunluk-Senesen, Gulay

    2009-01-01

    This paper assesses the glass ceiling for academics in the Turkish universities with reference to top administration positions: rectors and deans. Glass ceiling indicators show that the glass ceiling thickened from the 1990s to late 2000s. The findings are discussed against the background of the transformation in the Turkish universities in the…

  6. Air Distribution in Rooms with Ceiling-mounted Obstacles and Three-Dimensional Isothermal Flow

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Evensen, Louis; Grabau, Peter

    The air supply openings in ventilated rooms are often placed close to the ceiling. A recirculating flow is generated in the room, and the region between the ceiling and the occupied zone serves as an entrainment and velocity decay area for the wall jets. Ceiling-mounted obstacles may disturb...

  7. Assessing the variability of glacier lake bathymetries and potential peak discharge based on large-scale measurements in the Cordillera Blanca, Peru

    Science.gov (United States)

    Cochachin, Alejo; Huggel, Christian; Salazar, Cesar; Haeberli, Wilfried; Frey, Holger

    2015-04-01

    Over timescales of hundreds to thousands of years ice masses in mountains produced erosion in bedrock and subglacial sediment, including the formation of overdeepenings and large moraine dams that now serve as basins for glacial lakes. Satellite based studies found a total of 8355 glacial lakes in Peru, whereof 830 lakes were observed in the Cordillera Blanca. Some of them have caused major disasters due to glacial lake outburst floods in the past decades. On the other hand, in view of shrinking glaciers, changing water resources, and formation of new lakes, glacial lakes could have a function as water reservoirs in the future. Here we present unprecedented bathymetric studies of 124 glacial lakes in the Cordillera Blanca, Huallanca, Huayhuash and Raura in the regions of Ancash, Huanuco and Lima. Measurements were carried out using a boat equipped with GPS, a total station and an echo sounder to measure the depth of the lakes. Autocad Civil 3D Land and ArcGIS were used to process the data and generate digital topographies of the lake bathymetries, and analyze parameters such as lake area, length and width, and depth and volume. Based on that, we calculated empirical equations for mean depth as related to (1) area, (2) maximum length, and (3) maximum width. We then applied these three equations to all 830 glacial lakes of the Cordillera Blanca to estimate their volumes. Eventually we used three relations from the literature to assess the peak discharge of potential lake outburst floods, based on lake volumes, resulting in 3 x 3 peak discharge estimates. In terms of lake topography and geomorphology results indicate that the maximum depth is located in the center part for bedrock lakes, and in the back part for lakes in moraine material. Best correlations are found for mean depth and maximum width, however, all three empirical relations show a large spread, reflecting the wide range of natural lake bathymetries. Volumes of the 124 lakes with bathymetries amount to 0

  8. Trabecular bone mineral density measured by quantitative CT of the lumbar spine in children and adolescents: reference values and peak bone mass

    International Nuclear Information System (INIS)

    Berthold, L.D.; Alzen, G.; Haras, G.; Mann, M.

    2006-01-01

    Purpose: The aim of this study was to assess bone density values in the trabecular substance of the lumbar vertebral column in children and young adults in Germany from infancy to the age of peak bone mass. Materials and Methods: We performed quantiative computed tomography (QCT) on the first lumbar vertebra in 28 children and adolescents without diseases that may influence bone metabolism (15 boys, 13 girls, mean ages 11 and 8 years, respectively). We also measured 17 healthy young adults (9 men, 8 women, mean ages 20 and 21 years). We used a Somatom Balance Scanner (Siemens, Erlangen) and the Siemens Osteo software. Scan parameters: Slice thickness 1 cm, 80 kV, 81 or 114 mAs. We measured the trabecular bone density and the area and height of the vertebra and calculated the volume and content of calcium hydroxyapatite (Ca-HA) in the trabecular substance of the first lumbar vertebra. Results: Prepubertal boys had a mean bone density of 148.5 (median [med] 150.1, standard deviation [SD] 15.4) mg/Ca-HA per ml bone, and prepubertal girls had a mean density of 149.5 (med 150.8, SD 23.5) mg/ml. We did not observe a difference between prepubertal boys and girls. After puberty there was a significant difference (p<0.001) between males and females: Mean density (male) 158.0, med 162.5, SD 24.0 mg/ml, mean density (female) 191.2, med 191.3, SD 17.7 mg/ml. The Ca-HA content in the trabecular bone of the first lumbar vertebra was 1.1 (med 1.1, SD 0.5) g for prepubertal boys and 1.1 (0.9, 0.4) g for prepubertal girls. For post-pubertal males, the mean Ca-HA content was 3.5 g, med 3.5 SD 0.5 g, and for post-pubertal females, the mean content was 2.8, med 2.7, SD 0.4 g. Conclusion: The normal trabecular bone mineral density is 150 mg/ml with a standard deviation of 20 mg/ml independent of age or gender until the beginning of puberty. Peak bone mass (bone mineral content) in the trabecular substance of the lumbar vertebral column is higher in males than in females, and peak bone

  9. The Dependence of the Peak Velocity of High-Speed Solar Wind Streams as Measured in the Ecliptic by ACE and the STEREO satellites on the Area and Co-Latitude of their Solar Source Coronal Holes

    DEFF Research Database (Denmark)

    Hofmeister, Stefan J.; Veronig, Astrid; Temmer, Manuela

    2018-01-01

    We study the properties of 115 coronal holes in the time‐range from 2010/08 to 2017/03, the peak velocities of the corresponding high‐speed streams as measured in the ecliptic at 1AU, and the corresponding changes of the Kp index as marker of their geo‐effectiveness. We find that the peak velocit...

  10. Breaking through the glass ceiling: an industrial perspective.

    Science.gov (United States)

    Harlander, S K

    1996-11-01

    Many companies have recognized that the workforce of the future will be significantly more diverse than in the past. A substantial number of these new employees will be women. Industry must create an environment that attracts the best, brightest, and most talented women and provide an environment that empowers them to reach their full potential. Barriers to advancement, such as the real or perceived "glass ceiling," inhibit the individual and ultimately negatively affect the company. Successful companies will recognize that gender diversity is a critical business strategy and implement aggressive programs to assist women in breaking through the glass ceiling. Gender diversity initiatives should include examination of quality of life issues, training and development, organizational policies and practices, and management accountability. Mentoring programs clearly play an important role in gender diversity programs. Personal mentoring experiences in academic and corporate environments, as well as a pilot mentoring program at Land O'Lakes, will be discussed.

  11. Expatriate Glass Ceiling : The Perception of Malaysian Female Employees

    OpenAIRE

    Ghosh, Chandrika

    2013-01-01

    Evidence from research has repeatedly pointed to the small number of women managers sent on expatriation. The percentage of female expatriates during the 1990’s was as low as 14% of all expatriate managers (Windham/NFTC, 1997). Researchers found that, similar to the glass ceiling that prevents women from reaching top management levels, there seems to be another glass barrier that stops them from taking up international assignments. This subtle, invisible barrier has been referred to as the ex...

  12. Glass ceiling effects: the case of taiwanese top executives

    OpenAIRE

    Tzu-i Wang; Jennjou Chen

    2010-01-01

    Gender discrimination in labor markets has been an important issue in labor economics. The main purpose of this paper is to empirically study glass ceiling effects, and investigate whether female workers are indeed being discriminated against, particularly during the promotion process, in top management positions in Taiwan. This paper uses data from 4,485 large firms in Taiwan to study whether there are gender preferences when the chairperson of a company chooses a chief executive officer (CE...

  13. Rent sharing as a driver of the glass ceiling effect

    OpenAIRE

    Matano, Alessia; Naticchioni, Paolo

    2012-01-01

    In this paper we show that rent sharing plays a role in accounting for the glass ceiling effect. We make use of a unique employer-employee panel database for Italy from 1996 to 2003, which allows controlling for observed individual and firm heterogeneity and for collective bargaining. Moreover, by means of IV quantile fixed effects estimates we can cope with unobserved heterogeneity and endogeneity. We then go on to discuss the possible related explanations.

  14. Ocular Measures of Sleepiness Are Increased in Night Shift Workers Undergoing a Simulated Night Shift Near the Peak Time of the 6-Sulfatoxymelatonin Rhythm

    Science.gov (United States)

    Ftouni, Suzanne; Sletten, Tracey L.; Nicholas, Christian L.; Kennaway, David J.; Lockley, Steven W.; Rajaratnam, Shantha M.W.

    2015-01-01

    Study Objectives: The study examined the relationship between the circadian rhythm of 6-sulphatoxymelatonin (aMT6s) and ocular measures of sleepiness and neurobehavioral performance in shift workers undergoing a simulated night shift. Methods: Twenty-two shift workers (mean age 33.4, SD 11.8 years) were tested at approximately the beginning (20:00) and the end (05:55) of a simulated night shift in the laboratory. At the time point corresponding to the end of the simulated shift, 14 participants were classified as being within range of 6-sulphatoxymelatonin (aMT6s) acrophase— defined as 3 hours before or after aMT6s peak—and 8 were classified as outside aMT6s acrophase range. Participants completed the Karolinska Sleepiness Scale (KSS) and the auditory psychomotor vigilance task (aPVT). Waking electroencephalography (EEG) was recorded and infrared reflectance oculography was used to collect ocular measures of sleepiness: positive and negative amplitude/velocity ratio (PosAVR, NegAVR), mean blink total duration (BTD), the percentage of eye closure (%TEC), and a composite score of sleepiness levels (Johns Drowsiness Scale; JDS). Results: Participants who were tested within aMT6s acrophase range displayed higher levels of sleepiness on ocular measures (%TEC, BTD, PosAVR, JDS), objective sleepiness (EEG delta power frequency band), subjective ratings of sleepiness, and neurobehavioral performance, compared to those who were outside aMT6s acrophase range. Conclusions: The study demonstrated that objective ocular measures of sleepiness are sensitive to circadian rhythm misalignment in shift workers. Citation: Ftouni S, Sletten TL, Nicholas CL, Kennaway DJ, Lockley SW, Rajaratnam SM. Ocular measures of sleepiness are increased in night shift workers undergoing a simulated night shift near the peak time of the 6-sulfatoxymelatonin rhythm. J Clin Sleep Med 2015;11(10):1131–1141. PMID:26094925

  15. Influence of Ceiling Suspended Screen Positioning to the Scatter Radiation Levels in Interventional Cardiology

    International Nuclear Information System (INIS)

    Arandjic, D.; Bozovic, P.; Ciraj-Bjelac, O.; Antic, V.

    2013-01-01

    The objective of this paper is to identify the effects of the ceiling suspended screen position to the scatter radiation levels in the interventional cardiology. The scatter radiation in terms of ambient dose equivalent H * (10) was measured for various positions of protective screen in the positions of the first operator, nurse and radiographer, at elevations 100-190 cm and in four different angulations of the x-ray tube. To assess the effectiveness of the protective screen, the scattered dose was also measured in the absence of any protection in all four angulations and elevations. To simulate real clinical situation the measurements were performed in the presence of 30 cm PMMA phantom using standard clinical protocol. The utility of protective screen varied for different positions and angulations. Scatter radiation levels varied in the range 70 - 3400 μSv/h for the first operator, 140 - 3200 μSv/h for the nurse and 50 - 560 μSv/h for radiographer. Ceiling suspended screens can provide a substantial level of protection (up to factor 18) in interventional cardiology, but they have to be properly managed and positioned to achieve sufficient level of protection. The guidance for optimal protection is provided in the paper.(author)

  16. Peak reading detector circuit

    International Nuclear Information System (INIS)

    Courtin, E.; Grund, K.; Traub, S.; Zeeb, H.

    1975-01-01

    The peak reading detector circuit serves for picking up the instants during which peaks of a given polarity occur in sequences of signals in which the extreme values, their time intervals, and the curve shape of the signals vary. The signal sequences appear in measuring the foetal heart beat frequence from amplitude-modulated ultrasonic, electrocardiagram, and blood pressure signals. In order to prevent undesired emission of output signals from, e. g., disturbing intermediate extreme values, the circuit consists of the series connections of a circuit to simulate an ideal diode, a strong unit, a discriminator for the direction of charging current, a time-delay circuit, and an electronic switch lying in the decharging circuit of the storage unit. The time-delay circuit thereby causes storing of a preliminary maximum value being used only after a certain time delay for the emission of the output signal. If a larger extreme value occurs during the delay time the preliminary maximum value is cleared and the delay time starts running anew. (DG/PB) [de

  17. Atomization in graphite-furnace atomic absorption spectrometry. Peak-height method vs. integration method of measuring absorbance: carbon rod atomizer 63

    International Nuclear Information System (INIS)

    Sturgeon, R.E.; Chakrabarti, C.L.; Maines, I.S.; Bertels, P.C.

    1975-01-01

    Oscilloscopic traces of transient atomic absorption signals generated during continuous heating of a Carbon Rod Atomizer model 63 show features which are characteristic of the element being atomized. This research was undertaken to determine the significance and usefulness of the two analytically significant parameters, absorbance maximum and integrated absorbance. For measuring integrated absorbance, an electronic integrating control unit consisting of a timing circuit, a lock-in amplifier, and a digital voltmeter, which functions as a direct absorbance x second readout, has been designed, developed, and successfully tested. Oscilloscopic and recorder traces of the absorbance maximum and digital display of the integrated absorbance are simultaneously obtained. For the elements studied, Cd, Zn, Cu, Al, Sn, Mo, and V, the detection limits and the precision obtained are practically identical for both methods of measurements. The sensitivities by the integration method are about the same as, or less than, those obtained by the peak-height method, whereas the calibration curves by the former are generally linear over wider ranges of concentrations. (U.S.)

  18. Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube

    Science.gov (United States)

    Murphy, William J.; Fackler, Cameron J.; Berger, Elliott H.; Shaw, Peter B.; Stergar, Mike

    2015-01-01

    Impulse peak insertion loss (IPIL) was studied with two acoustic test fixtures and four hearing protector conditions at the E-A-RCAL Laboratory. IPIL is the difference between the maximum estimated pressure for the open-ear condition and the maximum pressure measured when a hearing protector is placed on an acoustic test fixture (ATF). Two models of an ATF manufactured by the French-German Research Institute of Saint-Louis (ISL) were evaluated with high-level acoustic impulses created by an acoustic shock tube at levels of 134 decibels (dB), 150 dB, and 168 dB. The fixtures were identical except that the E-A-RCAL ISL fixture had ear canals that were 3 mm longer than the National Institute for Occupational Safety and Health (NIOSH) ISL fixture. Four hearing protection conditions were tested: Combat Arms earplug with the valve open, ETYPlugs® earplug, TacticalPro headset, and a dual-protector ETYPlugs earplug with TacticalPro earmuff. The IPILs measured for the E-A-RCAL fixture were 1.4 dB greater than the National Institute for Occupational Safety and Health (NIOSH) ISL ATF. For the E-A-RCAL ISL ATF, the left ear IPIL was 2.0 dB greater than the right ear IPIL. For the NIOSH ATF, the right ear IPIL was 0.3 dB greater than the left ear IPIL. PMID:26356380

  19. Solar passive ceiling system. Final report. [Passive solar heating system with venetian blind reflectors and latent heat storage in ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, A.R.

    1980-01-01

    The construction of a 1200 square foot building, with full basement, built to be used as a branch library in a rural area is described. The primary heating source is a passive solar system consisting of a south facing window system. The system consists of: a set of windows located in the south facing wall only, composed of double glazed units; a set of reflectors mounted in each window which reflects sunlight up to the ceiling (the reflectors are similar to venetian blinds); a storage area in the ceiling which absorbs the heat from the reflected sunlight and stores it in foil salt pouches laid in the ceiling; and an automated curtain which automatically covers and uncovers the south facing window system. The system is totally passive and uses no blowers, pumps or other active types of heat distribution equipment. The building contains a basement which is normally not heated, and the north facing wall is bermed four feet high around the north side.

  20. Application of a novel measure of EEG non-stationarity as 'Shannon- entropy of the peak frequency shifting' for detecting residual abnormalities in concussed individuals.

    Science.gov (United States)

    Cao, Cheng; Slobounov, Semyon

    2011-07-01

    The aim of this report was to propose a novel measure of non-stationarity of EEG signals, named Shannon- entropy of the peak frequency shifting (SEPFS). The feasibility of this method was documented comparing this measure with traditional time domain assessment of non-stationarity and its application to EEG data sets obtained from student-athletes before and after suffering a single episode of mild traumatic brain injury (mTBI) with age-matched normal controls. Instead of assessing the power density distribution on the time-frequency plane, like previously proposed measures of signal non-stationarity, this new measure is based on the shift of the dominant frequency of the EEG signal over time. We applied SEPFS measure to assess the properties of EEG non-stationarity in subjects before and shortly after they suffered mTBI. Student-athletes at high risk for mTBI (n=265) were tested prior to concussive episodes as a baseline. From this subject pool, 30 athletes who suffered from mTBI were retested on day 30 post-injury. Additional subjects pool (student-athletes without history of concussion, n=30) were recruited and test-re-tested within the same 30 day interval. Thirty-two channels EEG signals were acquired in sitting eyes closed condition. The results showed that the SEPFS values significantly decreased in subjects suffering from mTBI. Specifically, reduced EEG non-stationarity was observed in occipital, temporal and central brain areas, indicating the possibility of residual brain dysfunctions in concussed individuals. A similar but less statistically significant trend was observed using traditional time domain analysis of EEG non-stationarity. The proposed measure has at least two merits of interest: (1) it is less affected by the limited resolution of time-frequency representation of the EEG signal; (2) it takes into account the neural characteristics of the EEG signal that have not been considered in previously proposed measures of non-stationarity. This new

  1. Experimental study on the dynamic performance of a novel system combining natural ventilation with diffuse ceiling inlet and TABS

    DEFF Research Database (Denmark)

    Yu, Tao; Heiselberg, Per Kvols; Lei, Bo

    2016-01-01

    Highlights • Dynamic experiments are performed to study energy performance of a new HVAC system. • Designed control strategies show good utilization of natural ventilation cooling. • TABS work well with the diffuse ceiling in the dynamic measurements. • No local thermal comfort problem is found...... even in the extreme winter case. • Designed control strategies can be used in the future application of this system....

  2. Hourly peak concentration measuring the PM2.5-mortality association: Results from six cities in the Pearl River Delta study

    Science.gov (United States)

    Lin, Hualiang; Ratnapradipa, Kendra; Wang, Xiaojie; Zhang, Yonghui; Xu, Yanjun; Yao, Zhenjiang; Dong, Guanghui; Liu, Tao; Clark, Jessica; Dick, Rebecca; Xiao, Jianpeng; Zeng, Weilin; Li, Xing; Qian, Zhengmin (Min); Ma, Wenjun

    2017-07-01

    Compared with daily mean concentration of air pollution, hourly peak concentration may be more directly relevant to the acute health effects due to the high concentration levels, however, few have analyzed the acute mortality effects of hourly peak levels of air pollution. We examined the associations of hourly peak concentration of fine particulate matter air pollution (PM2.5) with mortality in six cities in Pearl River Delta, China. We used generalized additive Poisson models to examine the associations with adjustment for potential confounders in each city. We further applied random-effects meta-analyses to estimate the regional overall effects. We further estimated the mortality burden attributable to hourly peak and daily mean PM2.5. We observed significant associations between hourly peak PM2.5 and mortality. Each 10 μg/m3 increase in 4-day averaged (lag03) hourly peak PM2.5 corresponded to a 0.9% [95% confidence interval (CI): 0.7%, 1.1%] increase in total mortality, 1.2% (95% CI: 1.0%, 1.5%) in cardiovascular mortality, and 0.7% (95% CI: 0.2%, 1.1%) in respiratory mortality. We observed a greater mortality burden using hourly peak PM2.5 than daily mean PM2.5, with an estimated 12915 (95% CI: 9922, 15949) premature deaths attributable to hourly peak PM2.5, and 7951 (95% CI: 5067, 10890) to daily mean PM2.5 in the Pearl River Delta (PRD) region during the study period. This study suggests that hourly peak PM2.5 might be one important risk factor of mortality in PRD region of China; the finding provides important information for future air pollution management and epidemiological studies.

  3. The Perception of 'Glass Ceiling' and its Impact on Career Progression of Female Managers in Malaysia

    OpenAIRE

    Khan, Maria

    2013-01-01

    The glass ceiling is a transparent barrier that prevents women and minorities from moving up in the management hierarchy. Glass ceiling researchers have attempted to determine whether a glass ceiling exists by examining the actual promotion decision to top management, the percentage of management positions held by women in an organization, salary of male versus female managers, and ratings of potential promotion candidates to top management. The aim of this research is to investigate the vari...

  4. Parametrical analysis on the diffuse ceiling ventilation by experimental and numerical studies

    DEFF Research Database (Denmark)

    Zhang, Chen; Kristensen, Martin Heine; Jensen, Jakob Sølund

    2016-01-01

    This paper aims to investigate the performance of diffuse ceiling ventilation in a classroom. An experimental study is carried out in a test chamber to examine the impact of diffuse ceiling opening area on the system cooling capacity and thermal comfort. The results indicate that diffuse ceiling ....... The numerical results reveal that even distribution of heat sources gives a lower draught risk environment than centralized distribution. In addition, there is a significant increase on the draught risk with increase of room height....

  5. Breaking the waves: modelling the potential impact of public health measures to defer the epidemic peak of novel influenza A/H1N1.

    Directory of Open Access Journals (Sweden)

    Matthias An der Heiden

    Full Text Available BACKGROUND: On June 11, 2009, the World Health Organization declared phase 6 of the novel influenza A/H1N1 pandemic. Although by the end of September 2009, the novel virus had been reported from all continents, the impact in most countries of the northern hemisphere has been limited. The return of the virus in a second wave would encounter populations that are still nonimmune and not vaccinated yet. We modelled the effect of control strategies to reduce the spread with the goal to defer the epidemic wave in a country where it is detected in a very early stage. METHODOLOGY/PRINCIPAL FINDINGS: We constructed a deterministic SEIR model using the age distribution and size of the population of Germany based on the observed number of imported cases and the early findings for the epidemiologic characteristics described by Fraser (Science, 2009. We propose a two-step control strategy with an initial effort to trace, quarantine, and selectively give prophylactic treatment to contacts of the first 100 to 500 cases. In the second step, the same measures are focused on the households of the next 5,000 to 10,000 cases. As a result, the peak of the epidemic could be delayed up to 7.6 weeks if up to 30% of cases are detected. However, the cumulative attack rates would not change. Necessary doses of antivirals would be less than the number of treatment courses for 0.1% of the population. In a sensitivity analysis, both case detection rate and the variation of R0 have major effects on the resulting delay. CONCLUSIONS/SIGNIFICANCE: Control strategies that reduce the spread of the disease during the early phase of a pandemic wave may lead to a substantial delay of the epidemic. Since prophylactic treatment is only offered to the contacts of the first 10,000 cases, the amount of antivirals needed is still very limited.

  6. Peaking-factor of PWR

    International Nuclear Information System (INIS)

    Morioka, Noboru; Kato, Yasuji; Yokoi, M.

    1975-01-01

    Output peaking factor often plays an important role in the safety and operation of nuclear reactors. The meaning of the peaking factor of PWRs is categorized into two features or the peaking factor in core (FQ-core) and the peaking factor on the basis of accident analysis (or FQ-limit). FQ-core is the actual peaking factor realized in nuclear core at the time of normal operation, and FQ-limit should be evaluated from loss of coolant accident and other abnormal conditions. If FQ-core is lower than FQ-limit, the reactor may be operated at full load, but if FQ-core is larger than FQ-limit, reactor output should be controlled lower than FQ-limit. FQ-core has two kinds of values, or the one on the basis of nuclear design, and the other actually measured in reactor operation. The first FQ-core should be named as FQ-core-design and the latter as FQ-core-measured. The numerical evaluation of FQ-core-design is as follows; FQ-core-design of three-dimensions is synthesized with FQ-core horizontal value (X-Y) and FQ-core vertical value, the former one is calculated with ASSY-CORE code, and the latter one with one dimensional diffusion code. For the evaluation of FQ-core-measured, on-site data observation from nuclear reactor instrumentation or off-site data observation is used. (Iwase, T.)

  7. Peak Experience Project

    Science.gov (United States)

    Scott, Daniel G.; Evans, Jessica

    2010-01-01

    This paper emerges from the continued analysis of data collected in a series of international studies concerning Childhood Peak Experiences (CPEs) based on developments in understanding peak experiences in Maslow's hierarchy of needs initiated by Dr Edward Hoffman. Bridging from the series of studies, Canadian researchers explore collected…

  8. First Ground-Based Infrared Solar Absorption Measurements of Free Tropospheric Methanol (CH3OH): Multidecade Infrared Time Series from Kitt Peak (31.9 deg N 111.6 deg W): Trend, Seasonal Cycle, and Comparison with Previous Measurements

    Science.gov (United States)

    Rinsland, Curtis P.; Mahieu, Emmanuel; Chiou, Linda; Herbin, Herve

    2009-01-01

    Atmospheric CH3OH (methanol) free tropospheric (2.09-14-km altitude) time series spanning 22 years has been analyzed on the basis of high-spectral resolution infrared solar absorption spectra of the strong vs band recorded from the U.S. National Solar Observatory on Kitt Peak (latitude 31.9degN, 111.6degW, 2.09-km altitude) with a 1-m Fourier transform spectrometer (FTS). The measurements span October 1981 to December 2003 and are the first long time series of CH3OH measurements obtained from the ground. The results were analyzed with SFIT2 version 3.93 and show a factor of three variations with season, a maximum at the beginning of July, a winter minimum, and no statistically significant long-term trend over the measurement time span.

  9. Constitutional guarantees gender equality and the reality of the 'glass ceiling' for women workers

    Directory of Open Access Journals (Sweden)

    Renato Bernardi

    2015-09-01

    Full Text Available The article makes an assessment of the distinction between the sexes and the preponderance of the male role in the labor market throughout history. It analyzes the existing legal framework before the promulgation of the Constitution of 1988 and after editing the adoption of measures coibitivas to gender discrimination, specifically on discrimination against women in the workplace. Seeking to understand the various forms of discrimination and analyzes equality to be achieved today. representative numbers of labor market behavior for women in IBGE statistics are presented. These data serve to corroborate the existence of the phenomenon of the "glass ceiling", ie the imaginary line that prevents the rise of women to senior positions, and economically hierarchical command positions. The conclusion, finally, the need to break these limits by adopting measures that restrict employers to keep promotions designed to gender criteria.

  10. Electricity Portfolio Management: Optimal Peak / Off-Peak Allocations

    OpenAIRE

    Huisman, Ronald; Mahieu, Ronald; Schlichter, Felix

    2007-01-01

    textabstractElectricity purchasers manage a portfolio of contracts in order to purchase the expected future electricity consumption profile of a company or a pool of clients. This paper proposes a mean-variance framework to address the concept of structuring the portfolio and focuses on how to allocate optimal positions in peak and off-peak forward contracts. It is shown that the optimal allocations are based on the difference in risk premiums per unit of day-ahead risk as a measure of relati...

  11. Peak-interviewet

    DEFF Research Database (Denmark)

    Raalskov, Jesper; Warming-Rasmussen, Bent

    Peak-interviewet er en særlig effektiv metode til at gøre ubevidste menneskelige ressourcer bevidste. Fokuspersonen (den interviewede) interviewes om en selvvalgt, personlig succesoplevelse. Terapeuten/coachen (intervieweren) spørger ind til processen, som ledte hen til denne succes. Herved afdæk...... fokuspersonen ønsker at tage op (nye mål eller nye processer). Nærværende workingpaper beskriver, hvad der menes med et peak-interview, peakinterviwets teoretiske fundament samt metodikken til at foretage et tillidsfuldt og effektiv peak-interview....

  12. Peak Oil, Peak Coal and Climate Change

    Science.gov (United States)

    Murray, J. W.

    2009-05-01

    Research on future climate change is driven by the family of scenarios developed for the IPCC assessment reports. These scenarios create projections of future energy demand using different story lines consisting of government policies, population projections, and economic models. None of these scenarios consider resources to be limiting. In many of these scenarios oil production is still increasing to 2100. Resource limitation (in a geological sense) is a real possibility that needs more serious consideration. The concept of 'Peak Oil' has been discussed since M. King Hubbert proposed in 1956 that US oil production would peak in 1970. His prediction was accurate. This concept is about production rate not reserves. For many oil producing countries (and all OPEC countries) reserves are closely guarded state secrets and appear to be overstated. Claims that the reserves are 'proven' cannot be independently verified. Hubbert's Linearization Model can be used to predict when half the ultimate oil will be produced and what the ultimate total cumulative production (Qt) will be. US oil production can be used as an example. This conceptual model shows that 90% of the ultimate US oil production (Qt = 225 billion barrels) will have occurred by 2011. This approach can then be used to suggest that total global production will be about 2200 billion barrels and that the half way point will be reached by about 2010. This amount is about 5 to 7 times less than assumed by the IPCC scenarios. The decline of Non-OPEC oil production appears to have started in 2004. Of the OPEC countries, only Saudi Arabia may have spare capacity, but even that is uncertain, because of lack of data transparency. The concept of 'Peak Coal' is more controversial, but even the US National Academy Report in 2007 concluded only a small fraction of previously estimated reserves in the US are actually minable reserves and that US reserves should be reassessed using modern methods. British coal production can be

  13. Ceiling art in a radiation therapy department: its effect on patient treatment experience

    International Nuclear Information System (INIS)

    Bonett, Jotham

    2015-01-01

    A new initiative has been implemented at the Sunshine Hospital Radiation Therapy Centre, to provide a calming and comforting environment for patients attending radiation therapy treatment. As part of this initiative, the department's computed tomography (CT) room and radiation therapy bunkers were designed to incorporate ceiling art that replicates a number of different visual scenes. The study was undertaken to determine if ceiling art in the radiation therapy treatment CT and treatment bunkers had an effect on a patient's experience during treatment at the department. Additionally, the study aimed to identify which of the visuals in the ceiling art were most preferred by patients. Patients were requested to complete a 12-question survey. The survey solicited a patient's opinion/perception on the unit's unique ceiling display with emphasis on aesthetic appeal, patient treatment experience and the patient's engagement due to the ceiling display. The responses were dichotomised to ‘positive’ or ‘negative’. Every sixth patient who completed the survey was invited to have a general face-to-face discussion to provide further information about their thoughts on the displays. The results demonstrate that the ceiling artwork solicited a positive reaction in 89.8% of patients surveyed. This score indicates that ceiling artwork contributed positively to patients’ experiences during radiation therapy treatment. The study suggests that ceiling artwork in the department has a positive effect on patient experience during their radiation therapy treatment at the department

  14. Numerical Prediction of Airflow in a Room with Ceiling-Mounted Obstacles

    DEFF Research Database (Denmark)

    Svidt, Kjeld

    In ventilated rooms the air inlet device is often placed close to the ceiling. The air inlet will form a wall jet or a reattached wall jet. The wall jet may be disturbed by ceilingmounted obstacles such as light fittings or ceiling beams which, in some cases, can cause the air jet to be deflected...

  15. Ceiling art in a radiation therapy department: its effect on patient treatment experience

    Energy Technology Data Exchange (ETDEWEB)

    Bonett, Jotham [Sunshine Hospital Radiation Therapy Centre, Melbourne, Vic. (Australia)

    2015-09-15

    A new initiative has been implemented at the Sunshine Hospital Radiation Therapy Centre, to provide a calming and comforting environment for patients attending radiation therapy treatment. As part of this initiative, the department's computed tomography (CT) room and radiation therapy bunkers were designed to incorporate ceiling art that replicates a number of different visual scenes. The study was undertaken to determine if ceiling art in the radiation therapy treatment CT and treatment bunkers had an effect on a patient's experience during treatment at the department. Additionally, the study aimed to identify which of the visuals in the ceiling art were most preferred by patients. Patients were requested to complete a 12-question survey. The survey solicited a patient's opinion/perception on the unit's unique ceiling display with emphasis on aesthetic appeal, patient treatment experience and the patient's engagement due to the ceiling display. The responses were dichotomised to ‘positive’ or ‘negative’. Every sixth patient who completed the survey was invited to have a general face-to-face discussion to provide further information about their thoughts on the displays. The results demonstrate that the ceiling artwork solicited a positive reaction in 89.8% of patients surveyed. This score indicates that ceiling artwork contributed positively to patients’ experiences during radiation therapy treatment. The study suggests that ceiling artwork in the department has a positive effect on patient experience during their radiation therapy treatment at the department.

  16. Do Asian American Faculty Face a Glass Ceiling in Higher Education?

    Science.gov (United States)

    Lee, Sharon M.

    2002-01-01

    Evaluated the glass ceiling hypothesis in relation to Asian American faculty using data from the 1993 National Study of Post-Secondary Faculty for 1,019 Asian American faculty members. Data limitations prevent concluding that such faculty do or do not face a glass ceiling; however, baseline findings for future research are established. (SLD)

  17. The glass ceiling of corporate social responsibility : Consequences of a business case approach towards CSR

    NARCIS (Netherlands)

    Nijhof, A.H.J.; Jeurissen, R.J.M.

    2010-01-01

    Purpose – This paper aims to clarify that corporate social responsibility (CSR) has come a long way by the prevailing business case approach, but increasingly hits a glass ceiling. The glass ceiling metaphor refers to the inherent limitations created by a business case approach towards CSR.

  18. THE IMPACT OF ORGANIZATIONAL STRUCTURE ON GLASS CEILING: AEGEAN REGION AGENCIES IN TURKEY

    OpenAIRE

    İNEL, Merve; GARAYEV, Vener; BAKAY, Aziz

    2014-01-01

    This study examined the relationship between organizationalstructure (mechanistic/organic) and glass ceiling, the concept known asnegative discrimination against women in workplace. The data collected fromrandomly selected 81 organizations in Aegean Region of Turkey was analyzedthrough hierarchical stepwise multiple regression. The results of the finalregression model suggest that glass ceiling is not dependent on organizationalstructure, while the control variable gender has a negative relat...

  19. Individually controlled localized chilled beam in conjunction with chilled ceiling: Part 2 – Human response

    DEFF Research Database (Denmark)

    Arghand, Taha; Pastuszka, Zuzanna; Bolashikov, Zhecho Dimitrov

    2016-01-01

    The response of 24 subjects to the local environment established by localized chilled beam combined with chilled ceiling (LCBCC) was studied and compared with response to the environment generated by mixing ventilation combined with chilled ceiling (CCMV) at two temperature conditions of 26°C and...

  20. Pipelines of Progress: An Update on the Glass Ceiling Initiative. A Status Report.

    Science.gov (United States)

    Department of Labor, Washington, DC.

    The "glass ceiling" refers to those barriers that have prevented the advancement of women and minorities into the top levels of executive management in major U.S. corporations. In 1991, the U.S. Department of Labor released a report describing the Glass Ceiling Initiative. This document reports on what occurred in the year following the…

  1. Individually controlled localized chilled beam in conjunction with chilled ceiling: Part 1 – Physical environment

    DEFF Research Database (Denmark)

    Arghand, Taha; Bolashikov, Zhecho Dimitrov; Kosonen, Risto

    2016-01-01

    This study investigates the indoor environment generated by localized chilled beam coupled with chilled ceiling (LCBCC) and compares it with the environment generated by mixing ventilation coupled with chilled ceiling (CCMV). The experiments were performed in a mock-up of single office (4.1 m × 4...

  2. Power peaking nuclear reliability factors

    International Nuclear Information System (INIS)

    Hassan, H.A.; Pegram, J.W.; Mays, C.W.; Romano, J.J.; Woods, J.J.; Warren, H.D.

    1977-11-01

    The Calculational Nuclear Reliability Factor (CNRF) assigned to the limiting power density calculated in reactor design has been determined. The CNRF is presented as a function of the relative power density of the fuel assembly and its radial local. In addition, the Measurement Nuclear Reliability Factor (MNRF) for the measured peak hot pellet power in the core has been evaluated. This MNRF is also presented as a function of the relative power density and radial local within the fuel assembly

  3. Evaluation of ceiling lifts: transfer time, patient comfort and staff perceptions.

    Science.gov (United States)

    Alamgir, Hasanat; Li, Olivia Wei; Yu, Shicheng; Gorman, Erin; Fast, Catherine; Kidd, Catherine

    2009-09-01

    Mechanical lifting devices have been developed to reduce healthcare worker injuries related to patient handling. The purpose of this study was to evaluate ceiling lifts in comparison to floor lifts based on transfer time, patient comfort and staff perceptions in three long-term care facilities with varying ceiling lift coverage. The time required to transfer or reposition patients along with patient comfort levels were recorded for 119 transfers. Transfers performed with ceiling lifts required on average less time (bed to chair transfers: 156.9 seconds for ceiling lift, 273.6 seconds for floor lift) and were found to be more comfortable for patients. In the three facilities, 143 healthcare workers were surveyed on their perceptions of patient handling tasks and equipment. For both transferring and repositioning tasks, staff preferred to use ceiling lifts and also found them to be less physically demanding. Further investigation is needed on repositioning tasks to ensure safe practice.

  4. Thresholds and Glass Ceilings: Career Pattern of Women Scientists

    Science.gov (United States)

    Sonnert, Gerhard

    2004-05-01

    The Project Access study examined the careers of men and women who had received prestigious postdoctoral fellowships and thus were presumably of about equal promise at the start of their professional careers. Had the women scientists in this elite group overcome a threshold beyond which they proceeded on equal footing with their male counterparts; or did a glass ceiling impede their careers? We found gender differences in career outcomes in the group we studied (699 questionnaires, 200 interviews), but these differences varied considerably by scientific discipline. Moreover, the career disparities for women, as a group, appear now to result chiefly from a series of subtle but identifiable and sometimes counterintuitive impediments as well as from slight gender differences in socialization. Each disadvantage by itself may be small, but in their accumulation they significantly influence women's careers.

  5. Air Distribution in a Room with Ceiling-Mounted Diffusers

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Heby, Thomas; Moeller-Jensen, Bertil

    2006-01-01

    . The characteristics of the air distribution systems are addressed by analysing the acceptable conditions for the supply flow rate and the temperature difference for the different systems. The paper shows that an air distribution system with ceiling-mounted air terminal units is able to generate comfortable velocity...... with swirling flow generates a flow pattern in the room which is rather uninfluenced by the thermal load. The flow is highly mixed above the occupied zone and the air movement penetrates the occupied zone close to the walls. All systems are tested in the same room with the same heat load consisting of two...... manikins, each sitting at a desk, two pc's and two desk lamps producing a total heat load of 480 W. The design of the air distribution system is in all five cases based on flow elements from the diffuser, a maximum velocity assumption and a critical vertical temperature gradient in the room...

  6. Peak regulation right

    International Nuclear Information System (INIS)

    Gao, Z. |; Ren, Z.; Li, Z.; Zhu, R.

    2005-01-01

    A peak regulation right concept and corresponding transaction mechanism for an electricity market was presented. The market was based on a power pool and independent system operator (ISO) model. Peak regulation right (PRR) was defined as a downward regulation capacity purchase option which allowed PRR owners to buy certain quantities of peak regulation capacity (PRC) at a specific price during a specified period from suppliers. The PRR owner also had the right to decide whether or not they would buy PRC from suppliers. It was the power pool's responsibility to provide competitive and fair peak regulation trading markets to participants. The introduction of PRR allowed for unit capacity regulation. The PRR and PRC were rated by the supplier, and transactions proceeded through a bidding process. PRR suppliers obtained profits by selling PRR and PRC, and obtained downward regulation fees regardless of whether purchases are made. It was concluded that the peak regulation mechanism reduced the total cost of the generating system and increased the social surplus. 6 refs., 1 tab., 3 figs

  7. Women's participation in parliament: 'Glass ceiling' syndrome and party selection

    Directory of Open Access Journals (Sweden)

    Čičkarić Lilijana

    2014-01-01

    Full Text Available The impact of 'glass ceiling' syndrome and party selection on participation of women in parliament and other political institutions are examined in this article. 'Glass ceiling' syndrome, which means invisible, but almost impenetrable border that women face in professional life, keeping them away from positions of influence and progress in career, is the main reason for the small number of women involved in politics. According to the focus of the research, there are three groups of barriers to women's political participation. Most researchers examine the influence of the political system, institutional and legal mechanisms, the question of their transparency and functional improvement. Significantly less frequent approach came from authors who are concentrated on the social and economic barriers, financial conditions and the broader social context. The third group consists of those who are considering the ideological and psychological barriers, patriarchal cultural patterns, traditional gender roles, self-confidence, ambition and women's desire to be involved in politics. Political parties are key actors in the process of discrimination against women, because they do not allow them to be selected in a number of political functions. There are many factors that determine that the issue of gender equality is variously interpreted in political parties. The most present are contextual and ideological factors, referring to a different definition of the status of women on the political agenda, the social climate in terms of gender equality and respect for human rights, the level of social development and political freedom. Then come organizational factors pertaining to the structure of parties, the manner in which the leadership is elected, whether there are internal women's pressure groups and lobbying, and are women leaders are visible on high positions in decision-making process. Finally, there are institutional-legal factors, which include the type

  8. Make peak flow a habit

    Science.gov (United States)

    Asthma - make peak flow a habit; Reactive airway disease - peak flow; Bronchial asthma - peak flow ... 2014:chap 55. National Asthma Education and Prevention Program website. How to use a peak flow meter. ...

  9. Automated asteroseismic peak detections

    DEFF Research Database (Denmark)

    de Montellano, Andres Garcia Saravia Ortiz; Hekker, S.; Themessl, N.

    2018-01-01

    Space observatories such as Kepler have provided data that can potentially revolutionize our understanding of stars. Through detailed asteroseismic analyses we are capable of determining fundamental stellar parameters and reveal the stellar internal structure with unprecedented accuracy. However......, such detailed analyses, known as peak bagging, have so far been obtained for only a small percentage of the observed stars while most of the scientific potential of the available data remains unexplored. One of the major challenges in peak bagging is identifying how many solar-like oscillation modes are visible...... of detected oscillation modes. The algorithm presented here opens the possibility for detailed and automated peak bagging of the thousands of solar-like oscillators observed by Kepler....

  10. Studi Deskriptif Persepsi Karyawan Hotel Tentang Glass Ceiling Pada Wanita Dalam Pencapaian Jabatan Puncak Manajemen Hotel Di Kota Tanjung Selor

    OpenAIRE

    Merang, Merycona

    2015-01-01

    Penelitian ini dilakukan untuk mengetahui persepsi karyawan hotel tentang glass ceiling pada wanita dalam pencapaian jabatan puncak manajemen hotel di kota Tanjung Selor. Glass ceiling memiliki enam variable yaitu diri sendiri, tingkat pendidikan, lingkungan keluarga, kesehatan, lingkungan sosial, dan lingkungan kerja.Teknik analisa yang digunakan adalah kuantitatif deskriptif, crosstab dan chi square. Hasil penelitian menunjukkan bahwa secara keseluruhan, persepsi karyawan tentang glass ceil...

  11. A score combining baseline neutrophilia and primary tumor SUV{sub peak} measured from FDG PET is associated with outcome in locally advanced cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Schernberg, Antoine; Sun, Roger; Chargari, Cyrus [Gustave Roussy Cancer Campus, Radiation Oncology Department, Villejuif (France); INSERM, U1030, Villejuif (France); Reuze, Sylvain [Gustave Roussy Cancer Campus, Radiation Oncology Department, Villejuif (France); INSERM, U1030, Villejuif (France); Universite Paris-Saclay, Univ Paris Sud, Le Kremlin-Bicetre (France); Gustave Roussy, Universite Paris-Saclay, Department of Medical Physics, Villejuif (France); Orlhac, Fanny [INSERM, U1030, Villejuif (France); Universite Paris-Saclay, CEA-SHFJ, IMIV, CEA, Inserm, CNRS, Univ. Paris-Sud, Orsay (France); Buvat, Irene [Universite Paris-Saclay, CEA-SHFJ, IMIV, CEA, Inserm, CNRS, Univ. Paris-Sud, Orsay (France); Dercle, Laurent [Gustave Roussy, Universite Paris-Saclay, Department of Nuclear Medicine and Endocrine Oncology, Villejuif (France); INSERM, U1015, Villejuif (France); Limkin, Elaine [INSERM, U1030, Villejuif (France); Universite Paris-Saclay, Univ Paris Sud, Le Kremlin-Bicetre (France); Escande, Alexandre; Haie-Meder, Christine [Gustave Roussy Cancer Campus, Radiation Oncology Department, Villejuif (France); Deutsch, Eric [Gustave Roussy Cancer Campus, Radiation Oncology Department, Villejuif (France); INSERM, U1030, Villejuif (France); Universite Paris-Saclay, Univ Paris Sud, Le Kremlin-Bicetre (France); Robert, Charlotte [Gustave Roussy Cancer Campus, Radiation Oncology Department, Villejuif (France); INSERM, U1030, Villejuif (France); Universite Paris-Saclay, Univ Paris Sud, Le Kremlin-Bicetre (France); Gustave Roussy, Universite Paris-Saclay, Department of Medical Physics, Villejuif (France)

    2018-02-15

    We investigated whether a score combining baseline neutrophilia and a PET biomarker could predict outcome in patients with locally advanced cervical cancer (LACC). Patients homogeneously treated with definitive chemoradiation plus image-guided adaptive brachytherapy (IGABT) between 2006 and 2013 were analyzed retrospectively. We divided patients into two groups depending on the PET device used: a training set (TS) and a validation set (VS). Primary tumors were semi-automatically delineated on PET images, and 11 radiomics features were calculated (LIFEx software). A PET radiomic index was selected using the time-dependent area under the curve (td-AUC) for 3-year local control (LC). We defined the neutrophil SUV grade (NSG = 0, 1 or 2) score as the number of risk factors among (i) neutrophilia (neutrophil count >7 G/L) and (ii) high risk defined from the PET radiomic index. The NSG prognostic value was evaluated for LC and overall survival (OS). Data from 108 patients were analyzed. Estimated 3-year LC was 72% in the TS (n = 69) and 65% in the VS (n = 39). In the TS, SUV{sub peak} was selected as the most LC-predictive biomarker (td-AUC = 0.75), and was independent from neutrophilia (p = 0.119). Neutrophilia (HR = 2.6), high-risk SUV{sub peak} (SUV{sub peak} > 10, HR = 4.4) and NSG = 2 (HR = 9.2) were associated with low probability of LC in TS. In multivariate analysis, NSG = 2 was independently associated with low probability of LC (HR = 7.5, p < 0.001) and OS (HR = 5.8, p = 0.001) in the TS. Results obtained in the VS (HR = 5.2 for OS and 3.5 for LC, p < 0.02) were promising. This innovative scoring approach combining baseline neutrophilia and a PET biomarker provides an independent prognostic factor to consider for further clinical investigations. (orig.)

  12. Automated asteroseismic peak detections

    Science.gov (United States)

    García Saravia Ortiz de Montellano, Andrés; Hekker, S.; Themeßl, N.

    2018-05-01

    Space observatories such as Kepler have provided data that can potentially revolutionize our understanding of stars. Through detailed asteroseismic analyses we are capable of determining fundamental stellar parameters and reveal the stellar internal structure with unprecedented accuracy. However, such detailed analyses, known as peak bagging, have so far been obtained for only a small percentage of the observed stars while most of the scientific potential of the available data remains unexplored. One of the major challenges in peak bagging is identifying how many solar-like oscillation modes are visible in a power density spectrum. Identification of oscillation modes is usually done by visual inspection that is time-consuming and has a degree of subjectivity. Here, we present a peak-detection algorithm especially suited for the detection of solar-like oscillations. It reliably characterizes the solar-like oscillations in a power density spectrum and estimates their parameters without human intervention. Furthermore, we provide a metric to characterize the false positive and false negative rates to provide further information about the reliability of a detected oscillation mode or the significance of a lack of detected oscillation modes. The algorithm presented here opens the possibility for detailed and automated peak bagging of the thousands of solar-like oscillators observed by Kepler.

  13. The Dependence of the Peak Velocity of High-Speed Solar Wind Streams as Measured in the Ecliptic by ACE and the STEREO satellites on the Area and Co-Latitude of their Solar Source Coronal Holes

    DEFF Research Database (Denmark)

    Hofmeister, Stefan J.; Veronig, Astrid; Temmer, Manuela

    2018-01-01

    We study the properties of 115 coronal holes in the time‐range from 2010/08 to 2017/03, the peak velocities of the corresponding high‐speed streams as measured in the ecliptic at 1AU, and the corresponding changes of the Kp index as marker of their geo‐effectiveness. We find that the peak...... statistically to zero, indicating that the associated high‐speed streams have a high chance to miss the Earth. Similar, the Kp index per coronal hole area is highest for the coronal holes located near the solar equator and strongly decreases with increasing latitudes of the coronal holes. We interpret...

  14. Peak stresses shift from femoral tunnel aperture to tibial tunnel aperture in lateral tibial tunnel ACL reconstructions: a 3D graft-bending angle measurement and finite-element analysis.

    Science.gov (United States)

    Van Der Bracht, Hans; Tampere, Thomas; Beekman, Pieter; Schepens, Alexander; Devriendt, Wouter; Verdonk, Peter; Victor, Jan

    2018-02-01

    To investigate the effect of tibial tunnel orientation on graft-bending angle and stress distribution in the ACL graft. Eight cadaveric knees were scanned in extension, 45°, 90°, and full flexion. 3D reconstructions with anatomically placed anterior cruciate ligament (ACL) grafts were constructed with Mimics 14.12 ® . 3D graft-bending angles were measured for classic medial tibial tunnels (MTT) and lateral tibial tunnels (LTT) with different drill-guide angles (DGA) (45°, 55°, 65°, and 75°). A pivot shift was performed on 1 knee in a finite-element analysis. The peak stresses in the graft were calculated for eight different tibial tunnel orientations. In a classic anatomical ACL repair, the largest graft-bending angle and peak stresses are seen at the femoral tunnel aperture. The use of a different DGA at the tibial side does not change the graft-bending angle at the femoral side or magnitude of peak stresses significantly. When using LTT, the largest graft-bending angles and peak stresses are seen at the tibial tunnel aperture. In a classic anatomical ACL repair, peak stresses in the ACL graft are found at the femoral tunnel aperture. When an LTT is used, peak stresses are similar compared to classic ACL repairs, but the location of the peak stress will shift from the femoral tunnel aperture towards the tibial tunnel aperture. the risk of graft rupture is similar for both MTTs and LTTs, but the location of graft rupture changes from the femoral tunnel aperture towards the tibial tunnel aperture, respectively. I.

  15. Experimental study of perforated suspended ceilings as diffuse ventilation air inlets

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2013-01-01

    An experimental study is reported in this paper for a diffuse ceiling ventilation concept. The analyses were carried out with two different porous surfaces mounted in a suspended ceiling: perforated tiles of aluminium and of gypsum. Ventilation air was supplied above the suspended ceiling effecti...... surface which increases the potential and applicability of the concept. Risk of thermal discomfort was not disclosed but the study did show evidence of large fluctuating air movements which could stem from transient behaviour creating sensations of draught to the occupants....

  16. Hardware Locks with Priority Ceiling Emulation for a Java Chip-Multiprocessor

    DEFF Research Database (Denmark)

    Strøm, Torur Biskopstø; Schoeberl, Martin

    2015-01-01

    According to the safety-critical Java specification, priority ceiling emulation is a requirement for implementations, as it has preferable properties, such as avoiding priority inversion and being deadlock free on uni-core systems. In this paper we explore our hardware supported implementation...... of priority ceiling emulation on the multicore Java optimized processor, and compare it to the existing hardware locks on the Java optimized processor. We find that the additional overhead for priority ceiling emulation on a multicore processor is several times higher than simpler, non-premptive locks, mainly...

  17. Analysis of Rapidly Developing Low Cloud Ceilings in a Stable Environment

    Science.gov (United States)

    Bauman, William H., III; Barrett, Joe H., III; Case, Jonathan L.; Wheeler, Mark M.; Baggett, G. Wayne

    2006-01-01

    Forecasters at the Space Meteorology Group (SMG) issue 30 to 90 minute forecasts for low cloud ceilings at the Space Shuttle Landing Facility (TTS) to support Space Shuttle landings. Mission verification statistics have shown ceilings to be the number one forecast challenge for SMG. More specifically, forecasters at SMG are concerned with any rapidly developing clouds/ceilings below 8000 ft in a stable, capped thermodynamic environment. Therefore, the Applied Meteorology Unit (AMU) was tasked to examine archived events of rapid stable cloud formation resulting in ceilings below 8000 ft, and document the atmospheric regimes favoring this type of cloud development. The AMU examined the cool season months of November to March during the years of 1993-2003 for days that had low-level inversions and rapid, stable low cloud formation that resulted in ceilings violating the Space Shuttle Flight Rules. The AMU wrote and modified existing code to identify inversions from the morning (-10 UTC) Cape Canaveral, FL rawinsonde (XMR) during the cool season and output pertinent sounding information. They parsed all days with cloud ceilings below 8000 ft at TTS, forming a database of possible rapidly-developing low ceiling events. Days with precipitation or noticeable fog burn-off situations were excluded from the database. In the first phase of this work, only the daytime hours were examined for possible ceiling development events since low clouds are easier to diagnose with visible satellite imagery. Phase II of this work includes expanding the database to include nighttime cases which is underway as this abstract is being written. For the nighttime cases, the AMU will analyze both the 00 UTC soundings and the 10 UTC soundings to examine those data for the presence of a low-level inversion. The 00 UTC soundings will probably not have a surface-based inversion, but the presence of inversions or "neutral" layers aloft and below 8,000 ft will most likely help define the stable

  18. Does the Glass Ceiling Exist?: A Cross-National Perspective on Gender Income Mobility

    OpenAIRE

    Ira N. Gang; John Landon-Lane; Myeong-Su Yun

    2003-01-01

    We compare male and female upward labor income mobility in Germany and the United States using the GSOEP-PSID Cross-National Equivalent File. Our main interest is to test whether a glass ceiling exists for women. Conventional thinking about the glass ceiling highlights the belief that the playing field is level for women and men in the labor market up to a certain point, after which there is an effective limit on advancement for women. We examine the glass ceiling hypothesis by looking at the...

  19. Does the Glass Ceiling Exist? A Cross-National Perspective on

    OpenAIRE

    Gang, Ira N.; Landon-Lane, John S.; Yun, Myeong-Su

    2003-01-01

    We compare male and female upward labor income mobility in Germany and the United States using the GSOEP-PSID Cross National Equivalent File. Our main interest is to test whether a glass ceiling exists for women. The standard glass ceiling hypothesis highlights the belief that the playing field is level for women and men in the labor market up to a point, after which there is an effective limit on advancement for women. We examine the glass ceiling hypothesis by looking at the dynamics of the...

  20. Performance of personalized ventilation combined with chilled ceiling in an office room: inhaled air quality and contaminant distribution

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Melikov, Arsen Krikor

    2014-01-01

    people (exhaled air, bioeffluents) and building materials (wall painting). Personalized ventilation combined with chilled ceiling ensured highest air quality at the workstation under all conditions. Pollutant concentration in the occupied zone away from the workstations did not differ substantially...... between the tested systems. Chilled ceiling combined with personalized ventilation working as the only air supplying system may be optimal solution in many buildings.......In a simulated two persons’ office room inhaled air quality and contaminant distribution provided with personalized ventilation combined with chilled ceiling, mixing ventilation only, chilled ceiling with mixing ventilation and chilled ceiling with mixing and personalized ventilation was studied...

  1. [Glass ceiling for women in academic medicine in France].

    Science.gov (United States)

    Rosso, C; Leger, A; Steichen, O

    2018-06-03

    To determine whether career development in academic medicine is more difficult for women than for men, and, if any, the nature and level of barriers to this progression. Extraction of full-time medical staff in a Parisian hospital group, through the SIGAPS platform; an online questionnaire survey of career choices and barriers experienced by full-time male and female physicians. The study population comprises 181 hospital practitioners and 141 academic physicians (49 associate professors and 92 full professors). Women represent 49% of the medical staff but 15% of full professors. This underrepresentation of women is more important among intensivists/anesthesiologists than technique-based specialists (such as radiologists, biologists…). There is no difference in scientific output, marital status and parenthood between women and men. On the other hand, there is a difference in attitudes highlighted by the EVAR risk-taking scale as well as in the burden of familial involvement and the prejudices felt by women during the academic selection process. The glass ceiling exists in one of the largest French hospital group. Career development principles promote merit, but should decrease the benefit of "masculine" attitudes in the competition for academic positions. Academic selection criteria should evolve to limit the disadvantage of women related to deeper familial involvement and less competitive strategies and risk-taking attitudes. Copyright © 2018 Société Nationale Française de Médecine Interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  2. Deposit Rate Ceilings as a Tool of Prudential Regulation

    Directory of Open Access Journals (Sweden)

    Janusz Krajewski

    2007-12-01

    Full Text Available The purpose of the paper is to present one of prudential regulation instruments in an environment that favors to engage in moral hazard behavior. The last decades proved that there is a link between financial liberalization and banking crises. In order to avoid crises and prevent banks engaging in gambling behavior, the system of prudential regulations has been implemented. The emphasis has been placed on the use of capital requirements, typically using the BIS standard developed in the Basel Accord.As the excessive reliance on capital requirements can become costly for the banks and lead to loose their franchise value and undermine incentives for prudent investing. The instrument that can create the franchise value, i.e. earning profits in the current period and in the future, is a policy of deposit rate controls. In the paper was also revealed why the policy of setting interest rate ceiling on deposits had not achieved its intended objectives, especially in the view of the fail of the Regulation Q policy.

  3. Sustainability assessment of a lightweight biomimetic ceiling structure

    International Nuclear Information System (INIS)

    Antony, Florian; Speck, Thomas; Speck, Olga; Grießhammer, Rainer

    2014-01-01

    An intensive and continuous debate centres on the question of whether biomimetics has a specific potential to contribute to sustainability. In the context of a case study, the objective of this paper is to contribute to this debate by presenting the first systematic approach to assess the sustainability of a complex biomimetic product. The object of inquiry is a lecture hall's ribbed slab. Based on criteria suggested by the Association of German Engineers (VDI), it has been verified that the slab has been correctly defined as biomimetic. Moreover, a systematic comparative product sustainability assessment has been carefully carried out. For purposes of comparison, estimated static calculations have been performed for conceivable current state-of-the-art lightweight ceiling structures. Alternative options are a hollow article slab and a pre-stressed flat slab. Besides a detailed benefit analysis and a discussion of social effects, their costs have also been compared. A particularly detailed life cycle assessment on the respective environmental impacts has also been performed. Results show that the biomimetic ribbed slab built in the 1960s is able to keep up with the current state-of-the-art lightweight solutions in terms of sustainability. These promising results encourage a systematic search for a broad range of sustainable biomimetic solutions. (paper)

  4. The glass ceiling in Irish healthcare: a nursing perspective.

    Science.gov (United States)

    Tracey, Catherine

    2006-01-01

    The purpose of this study is to describe and explore from the perspectives of top-level nurses holding the formal position of director of nursing their perceptions and interpretations of their experiences in the Irish healthcare system. This paper presents some findings from a nation-wide study, which is qualitative in approach using grounded theory methodology. Semi-structured interviews were conducted with 50 directors of nursing representing general and psychiatric nursing. The study in this paper was conducted in the context of a changing healthcare system, which emphasises the flattening of organisational pyramids. However, this study's findings indicate that, while structures might be changing, behaviours remain unaltered. In particular, the medicine nursing power base remains unchanged, while the power shift between nursing and general management continues to widen in favour of general management. Research in this paper shows that directors of nursing who chose to participate in this study may have different perceptions of experiences from those who chose not to participate. In the paper the reality is neither medicine nor general management, individually or collectively, are going to share or devolve power and influence to nursing. This study's findings indicate that nursing needs to confront this power imbalance. Nursing needs to take the first steps towards shattering the glass ceiling by really examining its own behaviours, in maintaining the status quo, in the traditional balance of power.

  5. Analyzing the glass ceiling effect among radiologic technologists.

    Science.gov (United States)

    Belinsky, Susan B; Blagg, James D

    2011-01-01

    The literature has suggested that advancement within politics, academia and the health professions is influenced by gender. Purpose The authors conducted a survey to determine whether advancement was equal by gender in the radiologic science disciplines of nuclear medicine technology, radiation therapy and radiography. The survey was mailed to 900 subjects, 300 from each discipline. The discipline groups were further stratified by initial year of American Registry of Radiologic Technology certification; the authors selected 100 subjects from each discipline who initially were certified in 1978, 100 in 1988 and 100 in 1998. Approximately 33% of those selected responded. The findings of the study provided no evidence that men are promoted differentially than women. Women perceived that men were paid more for the same work. It appears that gender bias is pervasive outside of promotion decisions and, indeed, that some illegal actions (eg, sexual harassment, inappropriate gender-related interview questions) take place in radiologic science clinical settings. It is hoped that this study will set a baseline for future research on whether there is a glass ceiling effect in radiologic clinical practice and stimulate discussion of the importance of equal opportunity regardless of gender.

  6. Intermittent Theta Burst Over M1 May Increase Peak Power of a Wingate Anaerobic Test and Prevent the Reduction of Voluntary Activation Measured with Transcranial Magnetic Stimulation.

    Science.gov (United States)

    Giboin, Louis-Solal; Thumm, Patrick; Bertschinger, Raphael; Gruber, Markus

    2016-01-01

    Despite the potential of repetitive transcranial magnetic stimulation (rTMS) to improve performances in patients suffering from motor neuronal afflictions, its effect on motor performance enhancement in healthy subjects during a specific sport task is still unknown. We hypothesized that after an intermittent theta burst (iTBS) treatment, performance during the Wingate Anaerobic Test (WAnT) will increase and supraspinal fatigue following the exercise will be lower in comparison to a control treatment. Ten subjects participated in two randomized experiments consisting of a WAnT 5 min after either an iTBS or a control treatment. We determined voluntary activation (VA) of the right knee extensors with TMS (VATMS) and with peripheral nerve stimulation (VAPNS) of the femoral nerve, before and after the WAnT. T-tests were applied to the WAnT results and a two way within subject ANOVA was applied to VA results. The iTBS treatment increased the peak power and the maximum pedalling cadence and suppressed the reduction of VATMS following the WAnT compared to the control treatment. No behavioral changes related to fatigue (mean power and fatigue index) were observed. These results indicate for the first time that iTBS could be used as a potential intervention to improve anaerobic performance in a sport specific task.

  7. Intermittent theta burst over M1 may increase peak power of a Wingate anaerobic test and prevent the reduction of voluntary activation measured with transcranial magnetic stimulation

    Directory of Open Access Journals (Sweden)

    Louis-Solal Giboin

    2016-07-01

    Full Text Available Despite the potential of repetitive transcranial magnetic stimulation (rTMS to improve performances in patients suffering from motor neuronal afflictions, its effect on motor performance enhancement in healthy subjects during a specific sport task is still unknown. We hypothesised that after an intermittent theta burst (iTBS treatment, performance during the Wingate Anaerobic Test (WAnT, will increase and supraspinal fatigue following the exercise will be lower in comparison to a control treatment.Ten subjects participated in two randomised experiments consisting of a WAnT 5 minutes after either an iTBS or a control treatment. We determined voluntary activation (VA of the right knee extensors with TMS (VATMS and with peripheral nerve stimulation (VAPNS of the femoral nerve, before and after the WAnT. T-tests were applied to the WAnT results and a 2 way within subject ANOVA was applied to VA results. The iTBS treatment increased the peak power and the maximum pedalling cadence and suppressed the reduction of VATMS following the WAnT compared to the control treatment. No behavioural changes related to fatigue (mean power and fatigue index were observed.These results indicate for the first time that iTBS could be used as a potential intervention to improve anaerobic performance in a sport specific task.

  8. Diffuse Ceiling Ventilation and the Influence of Room Height and Heat Load Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Vilsbøll, Rasmus W; Liu, Li

    2015-01-01

    Diffuse ceiling (inlet) ventilation is an air distribution system that supplies air from the entire ceiling surface, giving a low supply velocity. The flow pattern in the room is controlled by the heat sources. The system generates high mixing flow and the air velocities in the room are expected...... to be not much influenced by the flow rate to the room but dependent on the heat load. Previous studies have shown that diffuse ceiling ventilation has an ability to remove large heat loads without compromising the indoor climate. However, recent experiments indicate that the maximum accepted heat load decreases...... with a large room height and it decreases in connection with certain heat load distributions. Room geometries and heat load distributions that are optimal for diffuse ceiling ventilation are discussed. A simplified design procedure is introduced....

  9. Modeling of a hydronic ceiling system and its environment as energetic auditing tool

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca Diaz, Nestor [Universidad Tecnologica de Pereira, Facultad de Ingenieria Mecanica (Colombia); University of Liege Belgium, Thermodynamics Laboratory Campus du Sart Tilman - Bat: B49 - P33, B-4000 Liege (Belgium)

    2011-03-15

    As a part of a commissioning study, the chilled ceiling system of a large commercial building located in Belgium is evaluated. A representative office has been instrumented and data on the chilled ceiling system operating in real conditions have been collected. The simulation of the whole system is performed by means of a transient thermal model of the building and its HVAC system. The model considers the hydronic panels as a transient-state finned heat exchanger connected to a simplified lumped transient model of the building. The behavior of the hydronic ceiling system and the interactions with its environment (walls, ventilated facade, internal loads and ventilation system) has been experimentally and numerically evaluated. Commissioning test results show that the influence of surfaces temperatures inside the room, especially the facade, is considerable. Then, it is clear that the hydronic ceiling system must be evaluated together with its designed environment and not as a separate HVAC equipment. (author)

  10. Peak and Valley TOU One Effective DSM Measure Being Implemented Now%峰谷分时电价:一种现行有效的DSM措施

    Institute of Scientific and Technical Information of China (English)

    王治华; 唐为民; 李扬; 李军红; 张长沪

    2002-01-01

    TOU tariff is one of the measures for implementing the DSM. This paper introduces the appearance of DSMand its measures and main contents. TOU tariff's principle、structure and strategy of price-setting are also expounded. Finallythe effectiveness of TOU tariff is illustrated through the example of Nanjing.

  11. A Research on Glass Ceiling Syndrome Career Barriers of Women Academics

    OpenAIRE

    Serdar Öge; Alpay Karasoy; Özlem Kara

    2014-01-01

    Although women have merit in their jobs, they still are located very few in the top management in many sectors. There are many causes of such situation. Such a situation creates obstacles; especially invisible ones are called “glass ceiling syndrome”. Also, studies which handle this subject in academic community are very few. The aim of this research is to reach the results about glass ceiling obstacles in terms of female teaching staff (academics) working in higher educa...

  12. The relationship between glass ceiling and power distance as a cultural variable by a new method

    OpenAIRE

    Naide Jahangirov; Guler Saglam Ari; Seymur Jahangirov; Nuray Guneri Tosunoglu

    2015-01-01

    Glass ceiling symbolizes a variety of barriers and obstacles that arise from gender inequality at business life. With this mind, culture influences gender dynamics. The purpose of this research was to examine the relationship between the glass ceiling and the power distance as a cultural variable within organizations. Gender variable is taken as a moderator variable in relationship between the concepts. In addition to conventional correlation analysis, we employed a new method to investigate ...

  13. Do Female Researchers Face a Glass Ceiling in France? A Hazard Model of Promotions

    OpenAIRE

    Sabatier, Mareva

    2010-01-01

    Abstract The present article examines whether French female researchers face a glass ceiling, an invisible barrier to promotion. Using an original database from the National Institute for Agricultural Research, we estimate duration models for promotions. The methodology used allowed us to take into account censored observations and unobserved heterogeneity. Our results show a significant gender effect that does not contradict the glass-ceiling hypothesis. In addition, factors that ...

  14. Employer Attitudes towards Peak Hour Avoidance

    NARCIS (Netherlands)

    Vonk Noordegraaf, D.M.; Annema, J.A.

    2012-01-01

    Peak Hour Avoidance is a relatively new Dutch mobility management measure. To reduce congestion frequent car drivers are given a financial reward for reducing the proportion of trips that they make during peak hours on a specific motorway section. Although previous studies show that employers are

  15. Employer attitudes towards peak hour avoidance

    NARCIS (Netherlands)

    Noordegraaf, D.M.V.; Annema, J.A.

    2012-01-01

    Peak Hour Avoidance is a relatively new Dutch mobility management measure. To reduce congestion frequent car drivers are given a financial reward for reducing the proportion of trips that they make during peak hours on a specific motorway section. Although previous studies show that employers are

  16. Automated Peak Picking and Peak Integration in Macromolecular NMR Spectra Using AUTOPSY

    Science.gov (United States)

    Koradi, Reto; Billeter, Martin; Engeli, Max; Güntert, Peter; Wüthrich, Kurt

    1998-12-01

    A new approach for automated peak picking of multidimensional protein NMR spectra with strong overlap is introduced, which makes use of the program AUTOPSY (automatedpeak picking for NMRspectroscopy). The main elements of this program are a novel function for local noise level calculation, the use of symmetry considerations, and the use of lineshapes extracted from well-separated peaks for resolving groups of strongly overlapping peaks. The algorithm generates peak lists with precise chemical shift and integral intensities, and a reliability measure for the recognition of each peak. The results of automated peak picking of NOESY spectra with AUTOPSY were tested in combination with the combined automated NOESY cross peak assignment and structure calculation routine NOAH implemented in the program DYANA. The quality of the resulting structures was found to be comparable with those from corresponding data obtained with manual peak picking.

  17. PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Anuj [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system

  18. Exergy analysis in a space with ceiling shield; Analisis exegetico en un espacio con techo escudo

    Energy Technology Data Exchange (ETDEWEB)

    Laboratorio de Energia Solar, Universidad Nacional Autonoma de Mexico (Mexico)

    2009-07-15

    The Solar Laboratory of Energy (LES) of the Universidad Nacional Autonoma de Mexico (UNAM) was designed to be comfortable in spite of the extreme climate where it was built. One of the novel characteristics was the shield type ceiling used in cubicles. In order to compare the effect that had had with respect to the environmental conditions, one had to resort to an exergy analysis, since exergy is a measurement of the capacity of the energy to carry out a work. As a first system the data of the national meteorological system as initial conditions were used. The comparative system used as initial conditions the temperature and relative humidity measurements obtained in 1992 in a cubicle of the LES. Both systems were taken as open. The final conditions were settled at 25 Celsius degrees and 50% of relative humidity in a first case and variables (with respect to the perimeter a comfort zone) in a second case. The saving obtained was of 69% and 33% respectively. Although it is not possible to determine what percentage corresponds to the exclusive saving of the ceiling shield, we see that the cover all altogether, presents a significant exergy saving in respect to modifying the environmental conditions directly. [Spanish] El Laboratorio de Energia Solar (LES) de la Universidad Nacional Autonoma de Mexico (UNAM) fue disenado para ser confortable a pesar del clima extremoso donde fue construido. Una de las caracteristicas novedosas fue el uso de techo tipo escudo en cubiculo. Para comparar el efecto que se tuvo respecto a las condiciones ambientales, se recurrio a un analisis exergetico, ya que la exergia es una medida de la capacidad de la energia para realizar un trabajo. Como un primer sistema se utilizaron los datos del sistema meteorologico nacional como condiciones iniciales. El sistema comparativo utilizo como condiciones iniciales las mediciones de temperatura y humedad relativas obtenidas en 1992 en un cubiculo del LES. Ambos sistemas fueron tomados como abiertos

  19. 2D and 3D GPR imaging of structural ceilings in historic and existing constructions

    Science.gov (United States)

    Colla, Camilla

    2014-05-01

    GPR applications in civil engineering are to date quite diversified. With respect to civil constructions and monumental buildings, detection of voids, cavities, layering in structural elements, variation of geometry, of moisture content, of materials, areas of decay, defects, cracks have been reported in timber, concrete and masonry elements. Nonetheless, many more fields of investigation remain unexplored. This contribution gives an account of a variety of examples of structural ceilings investigation by GPR radar in reflection mode, either as 2D or 3D data acquisition and visualisation. Ceilings have a pre-eminent role in buildings as they contribute to a good structural behaviour of the construction. Primarily, the following functions can be listed for ceilings: a) they carry vertical dead and live loads on floors and distribute such loads to the vertical walls; b) they oppose to external horizontal forces such as wind loads and earthquakes helping to transfer such forces from the loaded element to the other walls; c) they contribute to create the box skeleton and behaviour of a building, connecting the different load bearing walls and reducing the slenderness and flexural instability of such walls. Therefore, knowing how ceilings are made in specific buildings is of paramount importance for architects and structural engineers. According to the type of building and age of construction, ceilings may present very different solutions and materials. Moreover, in existing constructions, ceilings may have been substituted, modified or strengthened due to material decay or to change of use of the building. These alterations may often go unrecorded in technical documentation or technical drawings may be unavailable. In many cases, the position, orientation and number of the load carrying elements in ceilings may be hidden or not be in sight, due for example to the presence of false ceilings or to technical plants. GPR radar can constitute a very useful tool for

  20. Isotope resolution of the iron peak

    International Nuclear Information System (INIS)

    Henke, R.P.; Benton, E.V.

    1977-01-01

    A stack of Lexan detectors from the Apollo 17 mission has been analyzed to obtain Z measurements of sufficient accuracy to resolve the iron peak into its isotopic components. Within this distribution several peaks are present. With the centrally located, most populated peak assumed to be 56 Fe, the measurements imply that the abundances of 54 Fe and 58 Fe are appreciable fractions of the 56 Fe abundance. This result is in agreement with those of Webber et al. and Siegman et al. but in disagreement with the predictions of Tsao et al. (Auth.)

  1. Comparison of the Performance of Chilled Beam with Swirl Jet and Diffuse Ceiling Air Supply: Impact of Heat Load Distribution

    DEFF Research Database (Denmark)

    Bertheussen, Bård; Mustakallio, Panu; Kosonen, Risto

    2013-01-01

    The impact of heat load strength and positioning on the indoor environment generated by diffuse ceiling air supply and chilled beam with radial swirl jet was studied and compared. An office room with two persons and a meeting room with six persons were simulated in a test room (4.5 x 3.95 x 3.5 m3......) and Category B thermal environment in the meeting room at high heat load of 94 W∙m−2. The air distribution pattern was influenced by the convective flows from the heat sources. The maximum local velocity in the occupied zone was 0.23–0.26 m∙s−1. The diffuse ceiling supply did not ensure complete mixing...... temperature was controlled at 24 °C. The quality of the generated indoor environment as defined in ISO standard 7730 (2005) was assessed based on comprehensive physical measurements. The systems created Category A thermal environment in cooling situations at heat load of 50 W∙m−2 and 78 W∙m−2 (office room...

  2. A practical method for determining γ-ray full-energy peak efficiency considering coincidence-summing and self-absorption corrections for the measurement of environmental samples after the Fukushima reactor accident

    Energy Technology Data Exchange (ETDEWEB)

    Shizuma, Kiyoshi, E-mail: shizuma@hiroshima-u.ac.jp [Graduate School of Engineering, Hiroshima University, Higashi-Hiroshima 739-8527 (Japan); Oba, Yurika; Takada, Momo [Graduate School of Integrated Arts and Sciences, Hiroshima University, Higashi-Hiroshima 739-8521 (Japan)

    2016-09-15

    A method for determining the γ-ray full-energy peak efficiency at positions close to three Ge detectors and at the well port of a well-type detector was developed for measuring environmental volume samples containing {sup 137}Cs, {sup 134}Cs and {sup 40}K. The efficiency was estimated by considering two correction factors: coincidence-summing and self-absorption corrections. The coincidence-summing correction for a cascade transition nuclide was estimated by an experimental method involving measuring a sample at the far and close positions of a detector. The derived coincidence-summing correction factors were compared with those of analytical and Monte Carlo simulation methods and good agreements were obtained. Differences in the matrix of the calibration source and the environmental sample resulted in an increase or decrease of the full-energy peak counts due to the self-absorption of γ-rays in the sample. The correction factor was derived as a function of the densities of several matrix materials. The present method was applied to the measurement of environmental samples and also low-level radioactivity measurements of water samples using the well-type detector.

  3. Modelling the line shape of very low energy peaks of positron beam induced secondary electrons measured using a time of flight spectrometer

    International Nuclear Information System (INIS)

    Fairchild, A J; Chirayath, V A; Gladen, R W; Chrysler, M D; Koymen, A R; Weiss, A H

    2017-01-01

    In this paper, we present results of numerical modelling of the University of Texas at Arlington’s time of flight positron annihilation induced Auger electron spectrometer (UTA TOF-PAES) using SIMION® 8.1 Ion and Electron Optics Simulator. The time of flight (TOF) spectrometer measures the energy of electrons emitted from the surface of a sample as a result of the interaction of low energy positrons with the sample surface. We have used SIMION® 8.1 to calculate the times of flight spectra of electrons leaving the sample surface with energies and angles dispersed according to distribution functions chosen to model the positron induced electron emission process and have thus obtained an estimate of the true electron energy distribution. The simulated TOF distribution was convolved with a Gaussian timing resolution function and compared to the experimental distribution. The broadening observed in the simulated TOF spectra was found to be consistent with that observed in the experimental secondary electron spectra of Cu generated as a result of positrons incident with energy 1.5 eV to 901 eV, when a timing resolution of 2.3 ns was assumed. (paper)

  4. Comparative Analysis Of Mid-Level Women Managers Perception Of The Existence Of Glass Ceiling In Singaporean And Malaysian Organizations

    OpenAIRE

    Vlado Dimovski; Miha Skerlavaj; Mandy Mok Kim Man

    2010-01-01

    This study presents an overview of glass-ceiling type barriers in organizations based on the perceptions of a sample of Singaporean and Malaysian mid-level women managers. Previous studies indicated the existence of a glass ceiling in organizations and presented strategic recommendations with regard to what corporations could do to remove or reduce the glass ceiling. This study investigates how women in middle management perceive their career advancement opportunities and what they consider t...

  5. Glass Ceiling in the Workplace: An Analysis within the Stated-owned Enterprises and Multi-national Enterprises in China

    OpenAIRE

    Cao, Mengxi

    2015-01-01

    Currently, although the increasingly number of women has gained leadership positions, the glass ceiling phenomenon still exists in China, especially in multi-national enterprise. In brief, the road to the upper rungs for female is still challenging and difficult. Due to the nature of the enterprises, the performance of glass ceiling is different. The aim of this dissertation is to discuss different performance and influence of glass ceiling in the context of the multi-national enterprises (MN...

  6. Graphite-modified cooling ceiling. A comparative evaluation of the performance; Graphitmodifizierte Kuehldecken. Eine vergleichende Bewertung zur Leistungsfaehigkeit

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, Gerd [Technische Univ. Muenchen (Germany); Fraunhofer-Institut fuer Bauphysik, Stuttgart (Germany); Hausladen, Gerhard [Technische Univ. Muenchen (Germany); Ingenieurbuero Hausladen GmbH, Muenchen (Germany); Jacobsen, Cornelia; Hutter, Christina; Hanusch, Christoph [Ingenieurbuero Hausladen GmbH, Muenchen (Germany); Schlitzberger, Stephan [Ingenieurbuero fuer Bauphysik Prof. Dr. Hauser GmbH, Kassel (Germany)

    2013-03-01

    In most cases, the utilization of graphite-modified building materials enhances their thermal conductivity. Thus, chilled ceiling systems achieve an enhanced thermal absorption in comparison to commercial chilled ceiling systems. For this, a simulation for the estimation of the thermal comfort as well as for the quantification of the impacts on the demand of electricity for the refrigeration is performed. The enhanced cooling capacity of the graphite-modified cooling ceiling 'Ecophit' affects the operation positively.

  7. Broadcast of four HD videos with LED ceiling lighting: optical-wireless MAC

    Science.gov (United States)

    Bouchet, Olivier; Porcon, Pascal; Gueutier, Eric

    2011-09-01

    The European project "hOME Gigabit Access Network" (OMEGA) targeted various wireless and wired solutions for 1 Gbit/s connectivity in Home Area Networks (HANs). One objective was to evaluate the suitability of optical wireless technologies in two spectral regions: visible light (visible-light communications - VLC) and near infrared (infrared communications - IRC). Several demonstrators have been built, all of them largely relying on overthe- shelf components. The demonstrators included a "wide-area" VLC broadcast link based on LED ceiling lighting and a laser-based high-data-rate "wide-area" IRC prototype. In this paper we discuss an adapted optical-wireless media-access-control (OWMAC) sublayer, which was developed and implemented during the project. It is suitable for both IRC and VLC. The VLC prototype is based on DMT signal processing and provides broadcasting at { 100 Mbit/s over an area of approximately 5 m2. The IRC prototype provides {300 Mbit/s half-duplex communication over an area of approximately 30 m2. The IRC mesh network, composed of one base station and two terminals, is based on OOK modulation, multi-sector transceivers, and an ultra-fast sector switch. After a brief discussion about the design of the optical-wireless data link layer and the optical-wireless switch (OWS) card, we address the card development and implementation. We also present applications for the VLC and IRC prototypes and measurement results regarding the MAC layer.

  8. The Impact of Roof Pitch and Ceiling Insulation on Cooling Load of Naturally-Ventilated Attics

    Directory of Open Access Journals (Sweden)

    Linxia Gu

    2012-07-01

    Full Text Available A 2D unsteady computational fluid dynamics (CFD model is employed to simulate buoyancy-driven turbulent ventilation in attics with different pitch values and ceiling insulation levels under summer conditions. The impacts of roof pitch and ceiling insulation on the cooling load of gable-roof residential buildings are investigated based on the simulation of turbulent air flow and natural convection heat transfer in attic spaces with roof pitches from 3/12 to 18/12 combined with ceiling insulation levels from R-1.2 to R-40. The modeling results show that the air flows in the attics are steady and exhibit a general streamline pattern that is qualitatively insensitive to the investigated variations of roof pitch and ceiling insulation. Furthermore, it is predicted that the ceiling insulation plays a control role on the attic cooling load and that an increase of roof pitch from 3/12 to 8/12 results in a decrease in the cooling load by around 9% in the investigated cases. The results suggest that the increase of roof pitch alone, without changing other design parameters, has limited impact on attics cooling load and airflow pattern. The research results also suggest both the predicted ventilating mass flow rate and attic cooling load can be satisfactorily correlated by simple relationships in terms of appropriately defined Rayleigh and Nusselt numbers.

  9. The effect of low ceiling on the external combustion of the cabin fire

    Science.gov (United States)

    Su, Shichuan; Chen, Changyun; Wang, Liang; Wei, Chengyin; Cui, Haibing; Guo, Chengyu

    2018-06-01

    External combustion is a phenomenon where the flame flares out of the window and burns outside. Because of the particularity of the ship's cabin structure, there is a great danger in the external combustion. In this paper, the numerical calculation and analysis of three kinds of low ceiling ship cabin fire are analyzed based on the large eddy numerical simulation technique. Through the analysis of temperature, flue gas velocity, heat flux density and so on, the external combustion phenomenon of fire development is calculated. The results show that when external combustion occurs, the amount of fuel escaping decreases with the roof height. The temperature above the window increases with the height of the ceiling. The heat flux density in the external combustion flame is mainly provided by radiation, and convection is only a small part; In the plume area there is a time period, in this time period, the convective heat flux density is greater than the radiation heat flux, this time with the ceiling height increases. No matter which ceiling height, the external combustion will seriously damage the structure of the ship after a certain period of time. The velocity distribution of the three roof is similar, but with the height of the ceiling, the area size is also increasing.

  10. Physical activity attenuates the mid-adolescent peak in insulin resistance but by late adolescence the effect is lost: a longitudinal study with annual measures from 9-16 years (EarlyBird 66).

    Science.gov (United States)

    Metcalf, Brad S; Hosking, Joanne; Henley, William E; Jeffery, Alison N; Mostazir, Mohammod; Voss, Linda D; Wilkin, Terence J

    2015-12-01

    The aim of this work was to test whether the mid-adolescent peak in insulin resistance (IR) and trends in other metabolic markers are influenced by long-term exposure to physical activity. Physical activity (7 day ActiGraph accelerometry), HOMA-IR and other metabolic markers (glucose, fasting insulin, HbA1c, lipids and BP) were measured annually from age 9 years to 16 years in 300 children (151 boys) from the EarlyBird study in Plymouth, UK. The activity level of each child was characterised, with 95% reliability, by averaging their eight annual physical activity measures. Age-related trends in IR and metabolic health were analysed by multi-level modelling, with physical activity as the exposure measure (categorical and continuous) and body fat percentage (assessed by dual-energy X-ray absorptiometry) and pubertal status (according to age at peak height velocity and Tanner stage) as covariates. The peak in IR at age 12-13 years was 17% lower (p adolescents independently of body fat percentage and pubertal status. However, this difference diminished progressively over the next 3 years and had disappeared completely by the age of 16 years (e.g. difference was -14% at 14 years, -8% at 15 years and +1% at 16 years; 'physical activity × age(2), interaction, p adolescence in the more active group. Our finding that physical activity attenuates IR during mid-adolescence may be clinically important. It remains to be established whether the temporary attenuation in IR during this period has implications for the development of diabetes in adolescence and for future metabolic health generally.

  11. Economic effects of peak oil

    International Nuclear Information System (INIS)

    Lutz, Christian; Lehr, Ulrike; Wiebe, Kirsten S.

    2012-01-01

    Assuming that global oil production peaked, this paper uses scenario analysis to show the economic effects of a possible supply shortage and corresponding rise in oil prices in the next decade on different sectors in Germany and other major economies such as the US, Japan, China, the OPEC or Russia. Due to the price-inelasticity of oil demand the supply shortage leads to a sharp increase in oil prices in the second scenario, with high effects on GDP comparable to the magnitude of the global financial crises in 2008/09. Oil exporting countries benefit from high oil prices, whereas oil importing countries are negatively affected. Generally, the effects in the third scenario are significantly smaller than in the second, showing that energy efficiency measures and the switch to renewable energy sources decreases the countries' dependence on oil imports and hence reduces their vulnerability to oil price shocks on the world market. - Highlights: ► National and sectoral economic effects of peak oil until 2020 are modelled. ► The price elasticity of oil demand is low resulting in high price fluctuations. ► Oil shortage strongly affects transport and indirectly all other sectors. ► Global macroeconomic effects are comparable to the 2008/2009 crisis. ► Country effects depend on oil imports and productivity, and economic structures.

  12. Integrated sound absorption in thermally activated concrete ceilings - acoustic and thermal effectiveness of sound-absorber strips spaced at intervals; Integrierte Schallabsorption in thermisch aktivierten Betondecken - akustische und thermische Wirksamkeit periodischer Schallabsorberstreifen

    Energy Technology Data Exchange (ETDEWEB)

    Drotleff, Horst; Wack, Roman; Leistner, Philip; Holm, Andreas; Ziegler, Matthias; Sedlbauer, Klaus [Fraunhofer-Institut fuer Bauphysik IBP, Stuttgart (Germany)

    2011-10-15

    From the perspectives of energy as well as indoor climate, thermally activated concrete ceilings make sense. Used in office buildings, however, their drawback becomes apparent: they are acoustically reflective. The conventional approaches use sound-absorbing suspended sails and absorber baffles or heat-conducting sound absorbers embedded in large areas of the concrete. In this paper, an alternative approach is presented and is evaluated acoustically and thermally. A few strips of sound absorber, arranged at intervals, are mounted flush into the concrete ceiling. To calculate the sound-absorption spectrum, an already widely publicised model (the Rayleigh approach) is used. It predicts the sound-absorption spectrum for normal sound incidence very well. For diffuse sound incidence, the difference to reverberation chamber measurements is greater, presumably because of the edge effect. The sound- absorption coefficient of the design can be tuned by skilful choice of the strip geometry, and it is significantly higher than the expected average value for the surface. On the one hand, the thermal efficiency of the components is determined by comparing the heat fluxes in the ceilings with absorber strips to an untreated reference ceiling. On the other hand, the indoor climate is investigated using a room model for office rooms of both solid and lightweight constructions. The influence of the strips (proportion of absorber area 20 %) on the thermal efficiency and indoor climate is low. Two absorber materials are examined in the strip approach: open-cell foam glass and a micro-perforated metallic absorber. While the metallic absorber displays thermal advantages, its sound absorption spectrum - even at high surface-coverage proportions - exhibits a much lower absorption coefficient than, for example, open-cell foam glass strips with only 20 % ceiling coverage. A demonstration in situ shows the potential of the absorber strips spaced at intervals. However, the method chosen in

  13. Final report development of a regional nitrogen ceiling; Eindrapportage ontwikkeling regionaal stikstofplafond

    Energy Technology Data Exchange (ETDEWEB)

    Bleeker, A.; Hensen, A. [ECN Environment and Energy Engineering, Petten (Netherlands); Rougoor, C. [Centrum voor Landbouw en Milieu CLM, Culemborg (Netherlands)

    2013-01-15

    The development of a methodology in which integrated nitrogen ceilings can be studied on a regional level is described. Next to the agricultural sector, also other sectors are taken into consideration (traffic, industry, etc.) with respect to the development of the nitrogen ceiling methodology. The study consists of two parts: the feasibility of a nitrogen ceiling system and the actual development of such a system [Dutch] Deze rapportage beschrijft de ontwikkeling van een methodiek waarbij integrale stikstofplafonds op gebiedsniveau kunnen worden bestudeerd. Dit onderzoek beschouwt, naast landbouw, ook andere sectoren (verkeer, industrie, etc.) voor het ontwikkelen van de stikstofplafond methodiek. Het onderzoek bestaat uit twee onderdelen: bestuderen van de haalbaarheid van een stikstofplafond systematiek en het feitelijke ontwikkelen van een dergelijke systematiek.

  14. Thermal environment and air quality in office with personalized ventilation combined with chilled ceiling

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Melikov, Arsen Krikor

    2015-01-01

    The thermal environment and air quality conditions provided with combined system of chilled ceiling and personalized ventilation (PV) were studied in a simulated office room for two occupants. The proposed system was compared with total volume HVAC solutions used today, namely mixing ventilation...... and chilled ceiling combined with mixing ventilation. The objective of the study was to evaluate whether PV can be the only ventilation system in the rooms equipped with chilled ceiling. The room air temperature was 26°C in cases with traditional systems and 28°C when PV was used. PV supplied air...... with the temperature of 25°C. PV improved thermal conditions and was up to nearly 10 times more efficient in delivering clean air at workstations than mixing ventilation systems, which resulted in strong protection of occupants from the cross-infection. In the room space outside workstations no substantial differences...

  15. Investigation of floor Nusselt number in floor heating system for insulated ceiling conditions

    International Nuclear Information System (INIS)

    Karadag, Refet; Teke, Ismail

    2007-01-01

    In this study, in a floor heated room, natural convection heat transfer over the floor is analysed numerically for different thermal conditions. An equation relevant to Nusselt number over the floor has been obtained by using the numerical data. Different equations are given in the literature. They consider the effect of floor Rayleigh number while neglecting the effect of wall and ceiling thermal conditions. Numerical data obtained in this study show that the Nusselt number over the floor depends on not only the floor Rayleigh number but also the wall Rayleigh number (for insulated ceiling conditions). The equations given in the literature are different from each other due to their not considering the effect of wall and ceiling Rayleigh numbers. This difference between the equations may be eliminated by obtaining an equation containing the effect of floor, wall and ceiling Rayleigh numbers. In this new approach, an equation relevant to the floor Nusselt number that depends on the floor and wall Rayleigh numbers has been obtained in the floor heating system for insulated ceiling conditions. The equation obtained in this study has been compared with the equations given in the literature. It has been seen that the equation obtained in this study matches the numerical values under more extensive thermal conditions than the equations given in the literature. The maximum deviation for the equations given in the literature is 35%, but in the current study, the maximum deviation has been found to be 10%. As a result, it is more convenient to use the equation found in the new approach as a function of Rayleigh number over the floor and wall for insulated ceiling conditions

  16. Impact of personalized ventilation combined with chilled ceiling on eye irritation symptoms

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Marcol, Bartosz; Kaczmarczyk, Jan

    2014-01-01

    Personalized ventilation (PV) improves inhaled air quality, because it provides fresh air to each workstation and directly to occupant’s breathing zone. The PV alone can be used for room ventilation when applied in conjunction with ceiling radiant cooling system, which removes sensible heat loads...... from the space. Combining PV with chilled ceiling may be an effective way to provide thermal comfort in rooms at air temperature higher than the recommended in the standards upper limit of 26°C (category II), because the operative temperature will be lower. However, combination of high air temperature...

  17. Influenza activity in Europe during eight seasons (1999–2007: an evaluation of the indicators used to measure activity and an assessment of the timing, length and course of peak activity (spread across Europe

    Directory of Open Access Journals (Sweden)

    Meijer Adam

    2007-11-01

    Full Text Available Abstract Background The European Influenza Surveillance Scheme (EISS has collected clinical and virological data on influenza since 1996 in an increasing number of countries. The EISS dataset was used to characterise important epidemiological features of influenza activity in Europe during eight winters (1999–2007. The following questions were addressed: 1 are the sentinel clinical reports a good measure of influenza activity? 2 how long is a typical influenza season in Europe? 3 is there a west-east and/or south-north course of peak activity ('spread' of influenza in Europe? Methods Influenza activity was measured by collecting data from sentinel general practitioners (GPs and reports by national reference laboratories. The sentinel reports were first evaluated by comparing them to the laboratory reports and were then used to assess the timing and spread of influenza activity across Europe during eight seasons. Results We found a good match between the clinical sentinel data and laboratory reports of influenza collected by sentinel physicians (overall match of 72% for +/- 1 week difference. We also found a moderate to good match between the clinical sentinel data and laboratory reports of influenza from non-sentinel sources (overall match of 60% for +/- 1 week. There were no statistically significant differences between countries using ILI (influenza-like illness or ARI (acute respiratory disease as case definition. When looking at the peak-weeks of clinical activity, the average length of an influenza season in Europe was 15.6 weeks (median 15 weeks; range 12–19 weeks. Plotting the peak weeks of clinical influenza activity reported by sentinel GPs against the longitude or latitude of each country indicated that there was a west-east spread of peak activity (spread of influenza across Europe in four winters (2001–2002, 2002–2003, 2003–2004 and 2004–2005 and a south-north spread in three winters (2001–2002, 2004–2005 and 2006

  18. The Dependence of the Peak Velocity of High-Speed Solar Wind Streams as Measured in the Ecliptic by ACE and the STEREO satellites on the Area and Co-latitude of Their Solar Source Coronal Holes.

    Science.gov (United States)

    Hofmeister, Stefan J; Veronig, Astrid; Temmer, Manuela; Vennerstrom, Susanne; Heber, Bernd; Vršnak, Bojan

    2018-03-01

    We study the properties of 115 coronal holes in the time range from August 2010 to March 2017, the peak velocities of the corresponding high-speed streams as measured in the ecliptic at 1 AU, and the corresponding changes of the Kp index as marker of their geoeffectiveness. We find that the peak velocities of high-speed streams depend strongly on both the areas and the co-latitudes of their solar source coronal holes with regard to the heliospheric latitude of the satellites. Therefore, the co-latitude of their source coronal hole is an important parameter for the prediction of the high-speed stream properties near the Earth. We derive the largest solar wind peak velocities normalized to the coronal hole areas for coronal holes located near the solar equator and that they linearly decrease with increasing latitudes of the coronal holes. For coronal holes located at latitudes ≳ 60°, they turn statistically to zero, indicating that the associated high-speed streams have a high chance to miss the Earth. Similarly, the Kp index per coronal hole area is highest for the coronal holes located near the solar equator and strongly decreases with increasing latitudes of the coronal holes. We interpret these results as an effect of the three-dimensional propagation of high-speed streams in the heliosphere; that is, high-speed streams arising from coronal holes near the solar equator propagate in direction toward and directly hit the Earth, whereas solar wind streams arising from coronal holes at higher solar latitudes only graze or even miss the Earth.

  19. 26 CFR 1.501(h)-3 - Lobbying or grass roots expenditures normally in excess of ceiling amount.

    Science.gov (United States)

    2010-04-01

    ... excess of ceiling amount. 1.501(h)-3 Section 1.501(h)-3 Internal Revenue INTERNAL REVENUE SERVICE... § 1.501(h)-3 Lobbying or grass roots expenditures normally in excess of ceiling amount. (a) Scope. This section provides rules under section 501(h) for determining whether an organization that has...

  20. DETECTION OF BACTERIAL CYTOTOXIC ACTIVITIES FROM WATER-DAMAGED CEILING TILE MATERIAL FOLLOWING INCUBATION ON BLOOD AGAR

    Science.gov (United States)

    Samples of ceiling tiles with high levels of bacteria exhibited cytotoxic activities on a HEP-2 tissue culture assay. Ceiling tiles containing low levels of bacterial colonization did not show cytotoxic activities on the HEP-2 tissue culture assay. Using a spread plate procedure ...

  1. What Do We Know about Glass Ceiling Effects? A Taxonomy and Critical Review to Inform Higher Education Research

    Science.gov (United States)

    Jackson, Jerlando F. L.; O'Callaghan, Elizabeth M.

    2009-01-01

    The concept of "glass ceiling effects" has emerged in social science research in general and higher education in particular over the past 20 years. These studies have described the impediments that women and people of color encounter in their quest for senior-level positions (e.g., CEOs) in society as glass ceiling effects. Literature, both…

  2. Peak-by-peak correction of Ge(Li) gamma-ray spectra for photopeaks from background

    International Nuclear Information System (INIS)

    Cutshall, N.H.; Larsen, I.L.

    1980-01-01

    Background photopeaks can interfere with accurate measurement of low levels of radionuclides by gamma-ray spectrometry. A flowchart for peak-by-peak correction of sample spectra to produce accurate results is presented. (orig.)

  3. Peak-by-peak correction of Ge(Li) gamma-ray spectra for photopeaks from background

    Energy Technology Data Exchange (ETDEWEB)

    Cutshall, N H; Larsen, I L [Oak Ridge National Lab., TN (USA)

    1980-12-01

    Background photopeaks can interfere with accurate measurement of low levels of radionuclides by gamma-ray spectrometry. A flowchart for peak-by-peak correction of sample spectra to produce accurate results is presented.

  4. Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Fang, Lei; Olesen, Bjarne W.

    2014-01-01

    vertical air temperature differences and air velocities for different hybrid systems are less than 3 C and 0.2 m/s when supply air temperature is 19 C, air change rate is 4.2 h-1, and heated surface temperature of floor/ceiling heating system is 25 C. Ventilation effectiveness of mixing ventilation system...... combined with floor/ceiling heating systems is approximately equal to 1.0, and ventilation effectiveness of displacement ventilation system combined with floor/ceiling heating systems ranges from 1.0 to 1.2. The floor/ceiling heating systems combined with mixing ventilation system have more uniform indoor...... air distribution but smaller ventilation effectiveness compared with the floor/ceiling heating systems combined with displacement ventilation system. With regard to the building heat loss increased by non-uniform indoor air distribution and small ventilation effectiveness, there should be an optimal...

  5. Reduced energy reqirement for air conditioning by using air diffusion with air flow from floor to ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H; Dittes, W; Mangelsdorf, R; Detzer, R; Jungbaeck, E; Fitzner, K; Radtke, W; Soethout, F

    1982-02-01

    The condition of the air in the occupied zone in airconditioned rooms is influenced by the mixing of supply air with room air. When supplying air from the ceiling there is a mixing all over the room, when supplying from the floor or from desks there is a mixing region only in the lower area. Above this their is warm air from which the return air is drawn. For air supply from below the cooling load can be decreased. In combination with the possible enthalpy difference between room air and supply air this decrease of the cooling load influences the necessary air rate. The interdependence of various air conditioning systems and various air temperatures is shown with a computer program. The load factor for various air distribution system at various cooling loads have been measured in a room of (8 x 5)m/sup 2/ x 3m. Experiments in a smaller model room (scale 1:3) showed how the heat was transported from the mixing region to the stratification region. The theoretically gained influence of the supply air jets of the height of the mixing region and on the load rate could be verified by the experiments. For the design of the fresh air rate, experience has been gained by measurements with tracegas (N/sub 2/O) in a third room. In comparing calculations the annual energy consumption has been computed for a building assuming various air conditioning systems and typical operation data. From experience with the existing systems the conclusions have been drawn how air distribution from floor to ceiling can be installed and operated.

  6. Evaluation of environmental and physiological factors of a whole ceiling-type air conditioner using a salivary biomarker

    Energy Technology Data Exchange (ETDEWEB)

    Tahara, Yusuke; Yamaguchi, Masaki [Graduate School of Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Morito, Naomi; Nishimiya, Hajime; Yamagishi, Hideyuki [Asahi Kasei Homes Corporation, R and D Laboratories, 2-1 Samejima, Fuji, Shizuoka 416-8501 (Japan)

    2009-06-15

    In order to improve environmental condition such as humidity and airflow in living spaces, a whole ceiling-type air conditioner is proposed. This novel air conditioner exhaust dispersed airflow from the whole ceiling by using a 3-dimensional knit fabric. The purpose of this paper is to reveal the effects when controlling humidity and airflow using the whole ceiling-type air conditioner compared to a commercialized concentrated exhaust air conditioner (normal-type air conditioner) under the same temperature. Salivary {alpha}-amylase activity (SAA) was used as an index of sympathetic nervous activity. An acute experiment for a 15 min period was conducted using 12 healthy young female adults. No significant differences in room and skin temperatures were observed between the whole ceiling-type air conditioner and the normal-type air conditioner. The whole ceiling-type air conditioner showed 11.1% lower humidity than the normal-type air conditioner. The whole ceiling-type air conditioner showed one-thirteenth the airflow of the normal-type air conditioner. As a result, the PMV of the whole ceiling-type air conditioner was more comfortable level than the normal one. Moreover, subjective evaluation questionnaire revealed a significant difference was observed in wind perception (windy). The SAA of subjects under the whole ceiling-type air conditioner showed significantly low values compared with the normal-type air conditioner. It was found that the subject's sympathetic nervous activity has been inactivated under the conditions of the whole ceiling-type air conditioner. Thus, it was revealed that the whole ceiling-type air conditioner provides a more comfortable air environment by reducing physical stimulations to humans. (author)

  7. 46 CFR 116.422 - Ceilings, linings, trim, interior finish and decorations.

    Science.gov (United States)

    2010-10-01

    ... specified by the Commandant; or (2) Listed by Underwriters Laboratories, does not exceed 2 millimeters (.075...) or UL 723 by an independent laboratory. (c) Bulkheads, linings, and ceilings in high risk... reasonable number of coats of paint or with a marine finish meeting the requirements of § 164.012 in...

  8. 42 CFR 413.40 - Ceiling on the rate of increase in hospital inpatient costs.

    Science.gov (United States)

    2010-10-01

    ... October 1, 2002, is the percentage increase projected by the hospital market basket index. (4) Target... target amount for the previous cost reporting period, updated by the market basket percentage increase... each cost reporting period, the ceiling is determined by multiplying the updated target amount, as...

  9. 78 FR 62494 - Energy Conservation Program: Energy Conservation Standards for Ceiling Fans

    Science.gov (United States)

    2013-10-22

    ... consumers' decisions about purchasing air conditioning equipment. For example: How much more or less likely are consumers to own or purchase an air conditioner if they already have a ceiling fan? How much more... and to facilitate this process, DOE has identified several related issues in this RFI on which DOE...

  10. Giuseppe Bragalli and Bolognese ceiling painting in the Czech Lands in the 17th century

    Czech Academy of Sciences Publication Activity Database

    Mádl, Martin

    2011-01-01

    Roč. 59, č. 5 (2011), s. 350-379 ISSN 0049-5123 R&D Projects: GA ČR GA408/08/0745 Institutional research plan: CEZ:AV0Z80330511 Keywords : baroque art * painting * ceiling painting * architecture Subject RIV: AL - Art, Architecture, Cultural Heritage

  11. Making Sense of the Glass Ceiling in Schools: An Exploration of Women Teachers' Discourses

    Science.gov (United States)

    Moreau, Marie-Pierre; Osgood, Jayne; Halsall, Anna

    2007-01-01

    There is extensive evidence of a "glass ceiling" for women across the labour market. Though schools have widely been described as "feminized" work environments, the under-representation of women at school management level is well established. Based on a study of women teachers' careers and promotion in the English school sector…

  12. Comments by ABCT's first female president on overcoming the glass ceiling.

    Science.gov (United States)

    Nelson-Gray, Rosemery O

    2012-12-01

    At the annual convention of the Association for Behavioral and Cognitive Therapies in New York City in November 2009, a most interesting panel discussion occurred: Overcoming the Glass Ceiling: A Conversation With the Trailblazers. This article is a written version of my oral presentation at this panel discussion in my role as ABCT's first female president. Copyright © 2012. Published by Elsevier Ltd.

  13. The Glass Ceiling for Women in Legal Education: Contract Positions and the Death of Tenure.

    Science.gov (United States)

    Angel, Marina

    2000-01-01

    Discussion of the glass ceiling for women in legal education first examines categories of law school personnel, especially the fast-growing category of legal-writing teachers, and then considers trends in law school hiring. Concludes that law school trends mirror those in college and university hiring generally, suggesting the weakening and…

  14. Perceptions of Women in Management: A Thematic Analysis of Razing the Glass Ceiling

    Science.gov (United States)

    Baumgartner, Mindy S.; Schneider, David E.

    2010-01-01

    Despite advances that women have made in organizations over the past century, women continue to be underrepresented in upper management positions. Based on a review of literature, six issues that women face when encountering the glass ceiling were examined. The goal of the current study involved having women who have succeeded at breaking the…

  15. Working beyond the Glass Ceiling: Women Managers in Initial Teacher Training in England

    Science.gov (United States)

    Thompson, Barbara

    2007-01-01

    Recently in England, women have been successful in obtaining managerial responsibilities in the field of teacher training. In this setting at least, it could be argued that the glass ceiling that has kept women in lower-paid and lower status posts has been shattered. In order to explore this proposition from the perspective of those who work as…

  16. Complete Model-Based Equivalence Class Testing for the ETCS Ceiling Speed Monitor

    DEFF Research Database (Denmark)

    Braunstein, Cécile; Haxthausen, Anne Elisabeth; Huang, Wen-ling

    2014-01-01

    In this paper we present a new test model written in SysML and an associated blackbox test suite for the Ceiling Speed Monitor (CSM) of the European Train Control System (ETCS). The model is publicly available and intended to serve as a novel benchmark for investigating new testing theories...

  17. Microbial Volatile Organic Compound Emissions from Stachybotrys chartarum growing on Gypsum Wallboard and Ceiling tile

    Science.gov (United States)

    This study compared seven toxigenic strains of S. chartarum found in water-damaged buildings to characterize the microbial volatile organic compound (MVOC) emissions profile while growing on gypsum wallboard (W) and ceiling tile (C) coupons. The inoculated coupons with their sub...

  18. Collusion through Price Ceilings? In Search of a Focal-Point Effect

    NARCIS (Netherlands)

    Engelmann, D.; Müller, W.

    2008-01-01

    With this study we resume the search for a collusive focal-point effect of price ceilings in laboratory markets. We argue that market conditions in previous studies were unfavorable for collusion which may have been responsible for not finding such a focal-point effect. Our design aims at maximizing

  19. Collusion through price ceilings? In search of a focal-point effect

    NARCIS (Netherlands)

    Engelmann, D.; Müller, W.

    2011-01-01

    We resume the search for a collusive focal-point effect of price ceilings in laboratory markets. We argue that market conditions in previous studies were unfavorable for collusion which may have been responsible for not finding such a focal-point effect. Our design aims at maximizing the likelihood

  20. Integrated Solution in an Office Room with Diffuse Ceiling Ventilation and Thermally Activated Building Constructions

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Pomianowski, Michal Zbigniew

    2015-01-01

    -scale experiments in a climate chamber. The experimental results indicate that diffuse ceiling can significantly improve thermal comfort in the occupied zone, by reducing draught risk and vertical temperature gradient. The linear function between pressure drop and air change rate points out that the air flow...

  1. Beyond the Glass Ceiling : The Glass Cliff and Its Lessons for Organizational Policy

    NARCIS (Netherlands)

    Bruckmueller, Susanne; Ryan, Michelle K.; Rink, Floor; Haslam, S. Alexander

    It has been almost 30 years since the metaphor of the glass ceiling was coined to describe the often subtle, but very real, barriers that women face as they try to climb the organizational hierarchy. Here we review evidence for a relatively new form of gender discriminationcaptured by the metaphor

  2. Is a Widening Gender Wage Gap Necessarily Caused by a Glass Ceiling?

    NARCIS (Netherlands)

    I.P. van Staveren (Irene)

    2012-01-01

    textabstractContrary to what is generally assumed, the gender wage gap and the glass ceiling may not necessarily be positively related. An exploratory analysis of aggregate public service personnel data for Uganda shows that the gender wage gap is small at the middle level of management, whereas it

  3. The relationship between glass ceiling and power distance as a cultural variable by a new method

    Directory of Open Access Journals (Sweden)

    Naide Jahangirov

    2015-12-01

    Full Text Available Glass ceiling symbolizes a variety of barriers and obstacles that arise from gender inequality at business life. With this mind, culture influences gender dynamics. The purpose of this research was to examine the relationship between the glass ceiling and the power distance as a cultural variable within organizations. Gender variable is taken as a moderator variable in relationship between the concepts. In addition to conventional correlation analysis, we employed a new method to investigate this relationship in detail. The survey data were obtained from 109 people working at a research center which operated as a part of the non-profit private university in Ankara, Turkey. The relationship between the variables was revealed by a new method which was developed as an addition to the correlation in survey. The analysis revealed that the female staff perceived the glass ceiling and the power distance more intensely than the male staff. In addition, the medium level relation was determined between the power distance and the glass ceiling perception among female staff.

  4. Numerical investigation of diffuse ceiling ventilation in an office under different operating conditions

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Petersen, Steffen

    2014-01-01

    is a numerical study of the performance of a six person office equipped with diffuse ventilation ceiling. In total six extreme, yet realistic, operation scenarios were simulated to study the performance including different occupancy, ventilation rates and supply air temperatures. The performance was studied...

  5. Airflow Pattern and Performance Analysis of Diffuse Ceiling Ventilation in an Office Room using CFD Study

    DEFF Research Database (Denmark)

    Zhang, Chen; Chen, Qingyan; Heiselberg, Per Kvols

    2015-01-01

    geometrical model and the other is a porous media model. The numerical models are validated by the full-scale experimental studies in a climate chamber. The results indicate that porous media model performed better on predicting air flow characteristic below diffuse ceiling and air velocity near the floor...

  6. You Can't Get There from Here: Working Women and the Glass Ceiling.

    Science.gov (United States)

    Business and Professional Women's Foundation, Washington, DC.

    Over the past two decades women and minorities have made unprecedented strides into the work force, yet discrimination due to gender and race is still a problem. The dearth of women in management is due to the "glass ceiling" phenomenon--the organizational, attitudinal, and societal barriers that effectively keep women and minorities…

  7. Female healthcare managers and the glass ceiling. The obstacles and opportunities for women in management.

    Science.gov (United States)

    Wiggins, C

    1991-01-01

    Despite the large number of women in the healthcare field, healthcare management resembles other industries in its severe lack of women in upper-management positions and in the "glass ceiling" that contributes to this dearth. Although not enough has been specifically written on women healthcare managers, the author reviews what is available, along with some of the general management literature.

  8. Between Meditation and Propaganda. Explicit and Implicit Religious Imagery in Baroque Ceiling Painting

    Czech Academy of Sciences Publication Activity Database

    Mádl, Martin

    2011-01-01

    Roč. 16, 1/2 (2011), s. 11-28 ISSN 1408-0419 R&D Projects: GA ČR GA408/08/0745 Institutional research plan: CEZ:AV0Z80330511 Keywords : baroque * ceiling painting * iconography * church Subject RIV: AL - Art, Architecture, Cultural Heritage

  9. Piercing the sovereign ceiling: Issues in oil and gas project financing

    International Nuclear Information System (INIS)

    Coleman, T.S.

    1998-01-01

    In the oil and gas sector, corporations and governments face huge capital spending requirements in order to transform large resource discoveries into producing, cash-generating assets. A significant portion of this funding is expected to be done on a project finance basis, where bank lenders or bond investors take a secured position in financing a discrete project, with the expectation of being paid back by the cash flows from that project after completion. This trend is increasing demand for crediting rating services to provide credit ratings for these project financings. A key challenge is to analyze and rate credit-worthy projects in countries that have relatively low foreign currency sovereign ceilings due to economic, political, and financial risks. In most cases, the credit ratings for projects financed in currencies outside the host country are capped at the country''s foreign currency ceiling. However, in a few instances, mainly in the oil and gas sector, Moody''s has pierced the foreign currency ceiling or rated certain projects above the sovereign ratings of the countries where they are domiciled. The purpose of this article is to briefly explain some of the qualitative factors and considerations that have allowed Moody''s to pierce the ceiling in the oil and gas sector, with a focus on two recent and noteworthy projects: Ras Laffan Liquefied Natural Gas in Qatar and Petrozuata in Venezuela

  10. [Impact of passing items above the ceiling on the assessment results of Peabody developmental motor scales].

    Science.gov (United States)

    Zhao, Gai; Bian, Yang; Li, Ming

    2013-12-18

    To analyze the impact of passing items above the roof level in the gross motor subtest of Peabody development motor scales (PDMS-2) on its assessment results. In the subtests of PDMS-2, 124 children from 1.2 to 71 months were administered. Except for the original scoring method, a new scoring method which includes passing items above the ceiling were developed. The standard scores and quotients of the two scoring methods were compared using the independent-samples t test. Only one child could pass the items above the ceiling in the stationary subtest, 19 children in the locomotion subtest, and 17 children in the visual-motor integration subtest. When the scores of these passing items were included in the raw scores, the total raw scores got the added points of 1-12, the standard scores added 0-1 points and the motor quotients added 0-3 points. The diagnostic classification was changed only in two children. There was no significant difference between those two methods about motor quotients or standard scores in the specific subtest (P>0.05). The passing items above a ceiling of PDMS-2 isn't a rare situation. It usually takes place in the locomotion subtest and visual-motor integration subtest. Including these passing items into the scoring system will not make significant difference in the standard scores of the subtests or the developmental motor quotients (DMQ), which supports the original setting of a ceiling established by upassing 3 items in a row. However, putting the passing items above the ceiling into the raw score will improve tracking of children's developmental trajectory and intervention effects.

  11. SU-E-T-499: Comparison of Measured Tissue Phantom Ratios (TPR) Against Calculated From Percent Depth Doses (PDD) with and Without Peak Scatter Factor (PSF) in 6MV Open Beam

    International Nuclear Information System (INIS)

    Narayanasamy, G; Cruz, W; Gutierrez, Alonso; Mavroidis, Panayiotis; Papanikolaou, N; Stathakis, S; Breton, C

    2014-01-01

    Purpose: To examine the accuracy of measured tissue phantom ratios (TPR) values with TPR calculated from percentage depth dose (PDD) with and without peak scatter fraction (PSF) correction. Methods: For 6MV open beam, TPR and PDD values were measured using PTW Semiflex (31010) ionization field and reference chambers (0.125cc volume) in a PTW MP3-M water tank. PDD curves were measured at SSD of 100cm for 7 square fields from 3cm to 30cm. The TPR values were measured up to 22cm depth for the same fields by continuous water draining method with ionization chamber static at 100cm from source. A comparison study was performed between the (a) measured TPR, (b) TPR calculated from PDD without PSF, (c) TPR calculated from PDD with PSF and (d) clinical TPR from RadCalc (ver 6.2, Sun Nuclear Corp). Results: There is a field size, depth dependence on TPR values. For 10cmx10cm, the differences in surface dose (DDs), dose at 10cm depth (DD10) <0.5%; differences in dmax (Ddmax) <2mm for the 4 methods. The corresponding values for 30cmx30cm are DDs, DD10 <0.2% and Ddmax<3mm. Even though for 3cmx3cm field, DDs and DD10 <1% and Ddmax<1mm, the calculated TPR values with and without PSF correction differed by 2% at >20cm depth. In all field sizes at depths>28cm, (d) clinical TPR values are larger than that from (b) and (c) by >3%. Conclusion: Measured TPR in method (a) differ from calculated TPR in methods (b) and (c) to within 1% for depths < 28cm in all 7 fields in open 6MV beam. The dmax values are within 3mm of each other. The largest deviation of >3% was observed in clinical TPR values in method (d) for all fields at depths < 28cm

  12. Establishment of peak bone mass.

    Science.gov (United States)

    Mora, Stefano; Gilsanz, Vicente

    2003-03-01

    Among the main areas of progress in osteoporosis research during the last decade or so are the general recognition that this condition, which is the cause of so much pain in the elderly population, has its antecedents in childhood and the identification of the structural basis accounting for much of the differences in bone strength among humans. Nevertheless, current understanding of the bone mineral accrual process is far from complete. The search for genes that regulate bone mass acquisition is ongoing, and current results are not sufficient to identify subjects at risk. However, there is solid evidence that BMD measurements can be helpful for the selection of subjects that presumably would benefit from preventive interventions. The questions regarding the type of preventive interventions, their magnitude, and duration remain unanswered. Carefully designed controlled trials are needed. Nevertheless, previous experience indicates that weight-bearing activity and possibly calcium supplements are beneficial if they are begun during childhood and preferably before the onset of puberty. Modification of unhealthy lifestyles and increments in exercise or calcium assumption are logical interventions that should be implemented to improve bone mass gains in all children and adolescents who are at risk of failing to achieve an optimal peak bone mass.

  13. Neurofeedback training for peak performance

    Directory of Open Access Journals (Sweden)

    Marek Graczyk

    2014-11-01

    Full Text Available [b]aim[/b]. One of the applications of the Neurofeedback methodology is peak performance in sport. The protocols of the neurofeedback are usually based on an assessment of the spectral parameters of spontaneous EEG in resting state conditions. The aim of the paper was to study whether the intensive neurofeedback training of a well-functioning Olympic athlete who has lost his performance confidence after injury in sport, could change the brain functioning reflected in changes in spontaneous EEG and event related potentials (ERPs. [b]case study[/b]. The case is presented of an Olympic athlete who has lost his performance confidence after injury in sport. He wanted to resume his activities by means of neurofeedback training. His QEEG/ERP parameters were assessed before and after 4 intensive sessions of neurotherapy. Dramatic and statistically significant changes that could not be explained by error measurement were observed in the patient. [b]conclusion[/b]. Neurofeedback training in the subject under study increased the amplitude of the monitoring component of ERPs generated in the anterior cingulate cortex, accompanied by an increase in beta activity over the medial prefrontal cortex. Taking these changes together, it can be concluded that that even a few sessions of neurofeedback in a high performance brain can significantly activate the prefrontal cortical areas associated with increasing confidence in sport performance.

  14. Reactor power peaking information display

    International Nuclear Information System (INIS)

    Book, T.L.; Kochendarfer, R.A.

    1986-01-01

    This patent describes a system for monitoring operating conditions within a nuclear reactor. The system consists of a method for measuring the operating parameters within the nuclear reactor, including the position of axial power shaping rods and regulating control rod. It also includes a method for determining from the operating parameters the operating limits before a power peaking condition exists within the nuclear reactor, and a method for displaying the operating limits which consists of a visual display permitting the continuous monitoring of the operating conditions within the nuclear reactor as a graph of the shaping rod position vs the regulating rod position having a permissible area and a restricted area. The permissible area is further divided into a recommended operating area for steady state operation and a cursor located on the graph to indicate the present operating condition of the nuclear reactor to allow an operator to view any need for corrective action based on the movement of the cursor out of the recommended operating area and to take any corrective transient action within the permissible area

  15. Neurofeedback training for peak performance.

    Science.gov (United States)

    Graczyk, Marek; Pąchalska, Maria; Ziółkowski, Artur; Mańko, Grzegorz; Łukaszewska, Beata; Kochanowicz, Kazimierz; Mirski, Andrzej; Kropotov, Iurii D

    2014-01-01

    One of the applications of the Neurofeedback methodology is peak performance in sport. The protocols of the neurofeedback are usually based on an assessment of the spectral parameters of spontaneous EEG in resting state conditions. The aim of the paper was to study whether the intensive neurofeedback training of a well-functioning Olympic athlete who has lost his performance confidence after injury in sport, could change the brain functioning reflected in changes in spontaneous EEG and event related potentials (ERPs). The case is presented of an Olympic athlete who has lost his performance confidence after injury in sport. He wanted to resume his activities by means of neurofeedback training. His QEEG/ERP parameters were assessed before and after 4 intensive sessions of neurotherapy. Dramatic and statistically significant changes that could not be explained by error measurement were observed in the patient. Neurofeedback training in the subject under study increased the amplitude of the monitoring component of ERPs generated in the anterior cingulate cortex, accompanied by an increase in beta activity over the medial prefrontal cortex. Taking these changes together, it can be concluded that that even a few sessions of neurofeedback in a high performance brain can significantly activate the prefrontal cortical areas associated with increasing confidence in sport performance.

  16. PEAK TRACKING WITH A NEURAL NETWORK FOR SPECTRAL RECOGNITION

    NARCIS (Netherlands)

    COENEGRACHT, PMJ; METTING, HJ; VANLOO, EM; SNOEIJER, GJ; DOORNBOS, DA

    1993-01-01

    A peak tracking method based on a simulated feed-forward neural network with back-propagation is presented. The network uses the normalized UV spectra and peak areas measured in one chromatogram for peak recognition. It suffices to train the network with only one set of spectra recorded in one

  17. Demonstration of an advanced solar garden with a water ceiling. Final technical report, July 1, 1979-June 30, 1980

    Energy Technology Data Exchange (ETDEWEB)

    Maes, R.; Riseng, C.; Thomas, G.; Mandeville, M.

    1980-09-01

    A history of the solar garden with the addition of the transparent water ceiling is presented, and a statement of the overall goals of the program is given. The objectives of the water ceiling grant are detailed. The rationale of the transparent water ceiling is developed and its implementation in the solar garden is described. The experimental procedures for evaluating the water ceiling as an integral part of an ongoing garden agricultural experiment are discussed and the results presented. The water ceiling has proven useful in providing extra thermal capacity to the solar garden. It provides heat at night after the water has been warmed during the day and retards overheating in the daytime by absorbing infrared energy into the water. In growing non-flowering plants, such as lettuce and Chinese cabbage, the water ceiling showed no noticeable degradation in yield or maturation rate. In flowering plants, such as tomatoes, the reduced light levels delayed yields by a couple of weeks but the total yield was only slightly diminished. In geographic areas where there is less cloud cover than in Michigan the water ceiling could be much more effective.

  18. Window screening, ceilings and closed eaves as sustainable ways to control malaria in Dar es Salaam, Tanzania

    Directory of Open Access Journals (Sweden)

    Chaki Prosper P

    2009-09-01

    Full Text Available Abstract Background Malaria transmission in Africa occurs predominantly inside houses where the primary vectors prefer to feed. Human preference and investment in blocking of specific entry points for mosquitoes into houses was evaluated and compared with known entry point preferences of the mosquitoes themselves. Methods Cross-sectional household surveys were conducted in urban Dar es Salaam, Tanzania to estimate usage levels of available options for house proofing against mosquito entry, namely window screens, ceilings and blocking of eaves. These surveys also enabled evaluation of household expenditure on screens and ceilings and the motivation behind their installation. Results Over three quarters (82.8% of the 579 houses surveyed in Dar es Salaam had window screens, while almost half (48.9% had ceilings. Prevention of mosquito entry was cited as a reason for installation of window screens and ceilings by 91.4% (394/431 and 55.7% (127/228 of respondents, respectively, but prevention of malaria was rarely cited (4.3%, 22/508. The median cost of window screens was between US $ 21-30 while that of ceilings was between US $301-400. The market value of insecticide-treated nets, window screening and ceilings currently in use in the city was estimated as 2, 5 and 42 million US$. More than three quarters of the respondents that lacked them said it was too expensive to install ceilings (82.2% or window screens (75.5%. Conclusion High coverage and spending on screens and ceilings implies that these techniques are highly acceptable and excellent uptake can be achieved in urban settings like Dar es Salaam. Effective models for promotion and subsidization should be developed and evaluated, particularly for installation of ceilings that prevent entry via the eaves, which are the most important entry point for mosquitoes that cause malaria, a variety of neglected tropical diseases and the nuisance which motivates uptake.

  19. Upper limit of peak area

    International Nuclear Information System (INIS)

    Helene, O.A.M.

    1982-08-01

    The determination of the upper limit of peak area in a multi-channel spectra, with a known significance level is discussed. This problem is specially important when the peak area is masked by the background statistical fluctuations. The problem is exactly solved and, thus, the results are valid in experiments with small number of events. The results are submitted to a Monte Carlo test and applied to the 92 Nb beta decay. (Author) [pt

  20. Measuring naturally occurring uranium in soil and minerals by analysing the 352 keV gamma-ray peak of 214Pb using a NaI(Tl)-detector

    International Nuclear Information System (INIS)

    Bezuidenhout, J.

    2013-01-01

    This article investigates the prospect of utilising the 351.9 keV gamma-ray of 214 Pb when determining the concentration of uranium. Soil samples were collected from various locations around South Africa and laboratory gamma ray spectra for each were obtained by means of a NaI(Tl)-detector (7.62×7.62 cm 2 ). The potassium, uranium and thorium concentrations where extracted by analysing gamma ray peaks that are associated with these radionuclides. Two separate uranium concentrations were extracted; one by means of the 214 Pb decay and the other one by means of the 214 Bi decay. These uranium concentrations were compared in terms of accuracies and detection limits. - Highlights: • Investigated a method to improve uranium concentrations measurements. • Expansion on an existing method that analyses naturally occurring radionuclides. • Utilise pill containers opposed to Marrinelli beakers. • Possible application to in situ measurements. • The method utilise NaI(Tl)-detectors with relative high efficiency

  1. Numerical modelling and experimental studies of thermal behaviour of building integrated thermal energy storage unit in a form of a ceiling panel

    International Nuclear Information System (INIS)

    Jaworski, Maciej; Łapka, Piotr; Furmański, Piotr

    2014-01-01

    Highlights: • A new concept of heat storage in ventilation ducts is described. • Ceiling panel as a part of ventilation system is made of a composite with PCM. • A set-up for experimental investigation of heat storage unit was built. • Numerical model of heat transfer in the storage unit was developed. • Numerical code was validated on the base of experimental measurements. - Abstract: Objective: The paper presents a new concept of building integrated thermal energy storage unit and novel mathematical and numerical models of its operation. This building element is made of gypsum based composite with microencapsulated PCM. The proposed heat storage unit has a form of a ceiling panel with internal channels and is, by assumption, incorporated in a ventilation system. Its task is to reduce daily variations of ambient air temperature through the absorption (and subsequent release) of heat in PCM, without additional consumption of energy. Methods: The operation of the ceiling panel was investigated experimentally on a special set-up equipped with temperature sensors, air flow meter and air temperature control system. Mathematical and numerical models of heat transfer and fluid flow in the panel account for air flow in the panel as well as real thermal properties of the PCM composite, i.e.: thermal conductivity variation with temperature and hysteresis of enthalpy vs. temperature curves for heating and cooling. Proposed novel numerical simulator consists of two strongly coupled sub models: the first one – 1D – which deals with air flowing through the U-shaped channel and the second one – 3D – which deals with heat transfer in the body of the panel. Results: Spatial and temporal air temperature variations, measured on the experimental set-up, were used to validate numerical model as well as to get knowledge of thermal performance of the panel operating in different conditions. Conclusion: Preliminary results of experimental tests confirmed the ability of

  2. Peak Oil and other threatening peaks-Chimeras without substance

    International Nuclear Information System (INIS)

    Radetzki, Marian

    2010-01-01

    The Peak Oil movement has widely spread its message about an impending peak in global oil production, caused by an inadequate resource base. On closer scrutiny, the underlying analysis is inconsistent, void of a theoretical foundation and without support in empirical observations. Global oil resources are huge and expanding, and pose no threat to continuing output growth within an extended time horizon. In contrast, temporary or prolonged supply crunches are indeed plausible, even likely, on account of growing resource nationalism denying access to efficient exploitation of the existing resource wealth.

  3. The analysis of glass ceiling phenomenon in the promotion of women’s abilities in organizations

    Directory of Open Access Journals (Sweden)

    Mahboubeh Soleymanpour Omran

    2015-09-01

    Full Text Available Women constitute almost half of the workforce of a society and there has been considerable increase in women employment rate in recent years. However, their promotion to management positions has not been very tangible. Gender inequalities in the workplace especially in the domain of management have resulted in the lack of efficient use of potential capacities of women. Even though the previous research demonstrates that women are not less ambitious than men, wrong beliefs which attribute management to men make a kind of invisible barrier, known as glass ceiling, which prevents women’s promotion to top organizational positions. The purpose of this study was to investigate the reasons for the lack of promotion of women to top management levels in the society. It was conducted with a descriptive analytic method through the review of the related literature and emphasis on the concept of glass ceiling to present practical solutions to solve the problem.

  4. Raising the "glass ceiling" for ethnic minority women in health care management.

    Science.gov (United States)

    Kumar, R; Johnston, G

    1999-01-01

    Ethnic minority women are well represented in the work force and in the health care system in general, but do not have a similar level of representation in the management sector. This paper explores three strategies for schools of health administration to consider to lessen the effect of a "glass ceiling" that may be encountered by ethnic minority women aspiring to positions of leadership in health services agencies. These strategies are advancing affirmative action, valuing ethnic women in health administration education, and investigating diversity management. Inherent in each of the three strategies is the need for acknowledgment and more open discussion of the "glass ceiling." Problem-solving in relation to the potential for systemic discrimination adversely affecting ethnic minority women in senior health care management positions, and greater study of the three strategies using both qualitative and quantitative methodologies is also needed.

  5. Ceiling of care decisions at an older person's mental health unit in Gloucestershire.

    Science.gov (United States)

    Slack, Philip; Rose, Anneka

    2015-01-01

    This quality improvement project was inspired as an answer to a problem that many fellow psychiatric trainees had been struggling with while on-call covering the old age mental health hospital which includes a specialist dementia ward. The issue was that decisions around ceilings of care for patients were often not discussed or at least recorded in the electronic notes and as a result when reviewing deteriorating patients out of hours trainees would find themselves without any guidance on the treating medics opinion on what was in the best interests of the patient. This led to situations where unnecessary transfers to the acute hospital would occur overnight which could have been avoided with more consistent planning. Prior to initiating the changes it was recorded that nine out of 47 inpatients had documented decisions on ceiling of care of treatment in the consultant's ward round entries. Next policies from acute hospitals were reviewed, opinions were discussed in departmental meetings, and eventually there was agreed a change in procedure with the consultant on the dementia ward around resuscitation and ceiling of care status and consistent recording of this. Following the intervention there was seen an improvement in the recording of decisions around treatment and transfer of patients on the dementia ward of 80% (4/5) fully compliant with new criteria and then 71% (5/7) in successive cycles. Further communication both with relevant professionals on the old age ward and with the trainees on the on-call rota will be necessary to sustain any change but the centralised recording of resuscitation status and ceiling of care in the ward round entries have provided much more guidance than was previously available. In the future it may be possible to spread this policy throughout the entire old age mental health unit.

  6. The glass ceiling and women in management in the Middle East: Myth or reality

    OpenAIRE

    Marinakou, Evangelia

    2014-01-01

    Although globalization and equal employment have created opportunities for female managers, they are still underrepresented in the corporate ladder. Gender and gender role stereotypes are persistent in organizations that operate in the Middle East, challenging women’s employment and showing evidence of the glass ceiling in management. This paper explores the position of women in management in the Kingdom of Bahrain, as well as the barriers they face in climbing the career ladder. The findings...

  7. Does Organizational Culture Affect the Perception Towards the Barriers of the Glass Ceiling?

    OpenAIRE

    Muruatetu, Ndunge

    2011-01-01

    Purpose : The purpose of this study was to examine the existence of the glass ceilling in Africa; and to investigate whether organizational culture affected the perception towards the barriers of the glass ceiling. Design/Methodology : This research used a quatitative approach, based on a descriptive design. Data was gathered from surveys issued to employees at a Non-Governmental organization; with the participants based in the Sierra Leone and Democratic Republic of Congo offices. Fi...

  8. How to use your peak flow meter

    Science.gov (United States)

    ... meter - how to use; Asthma - peak flow meter; Reactive airway disease - peak flow meter; Bronchial asthma - peak ... 2014:chap 55. National Asthma Education and Prevention Program website. How to use a peak flow meter. ...

  9. Europe and oil: beware of the glass ceiling

    International Nuclear Information System (INIS)

    Durand, B.

    2011-01-01

    Because current oil exporting countries consume an increasing share of their production and will shortly be producing less and less, available amounts of oil for the international market will decrease faster than world production, in spite of the emergence of new exporting countries such as Brazil or Kazakhstan. Owing to expanding consumption of major emerging countries, the share le for developed countries will drop rapidly, by approximately one third in the coming fifteen years. Europe, whose oil reserves will soon be exhausted, will almost entirely depend on outside sources. If it does not adjust through massive and swift consumption reduction, its material growth will be durably jeopardized due to substantial oil price increases. The adjustment requires strong and urgent measures to reduce the consumption of oil-based fuel in transportation, as well as of fuel oil by the residential and tertiary sectors. A selection of measures is set out. (author)

  10. Preliminary research on the glass ceiling phenomenon in accounting and financial audit practice in Poland

    Directory of Open Access Journals (Sweden)

    Aleksandra Szewieczek

    2017-09-01

    Full Text Available Preliminary research on the glass ceiling phenomenon in accounting and financial audit practice in Poland The paper analyzes the glass ceiling phenomenon in the accounting practice in Poland. The essence and characteristics of this phenomenon are presented in relation to the accounting profession and statutory auditors. Research on the ‘glass ceiling’ carried out in various countries, with a particular reference to the profession of a statutory auditor, was reviewed. The paper presents results of the research on the phenomenon conducted among a selected sample of audit firms in Poland. The results of the study confirmed the occurrence of this phenomenon in Poland with greater intensity in larger entities. The large scale of the glass ceiling phenomenon in the professional life of women in accounting is reflected by a high percentage of women in the profession of statutory auditor contrasted by the very low participation in senior managerial positions, e.g. partners in auditing companies. The paper uses the method of critical analysis of the literature and empirical data. Moreover, qualitative analysis was used for the data reported by audit firms

  11. Does drywall installers' innovative idea reduce the ergonomic exposures of ceiling installation: A field case study.

    Science.gov (United States)

    Dasgupta, Priyadarshini Sengupta; Punnett, Laura; Moir, Susan; Kuhn, Sarah; Buchholz, Bryan

    2016-07-01

    The study was conducted to assess an intervention suggested by the workers to reduce the physical or ergonomic exposures of the drywall installation task. The drywall installers were asked to brainstorm on innovative ideas that could reduce their ergonomic exposures during the drywall installation work. The workers proposed the idea of using a 'deadman' (narrow panel piece) to hold the panels to the ceiling while installing them. The researcher collected quantitative exposure data (PATH, 3DSSPP) at the baseline and intervention phases and compared the phases to find out any change in the exposure while using the 'deadman'. Results showed that ergonomic exposures (such as overhead arm and awkward trunk postures and heavy load handling) were reduced at the intervention phase while using the 'deadman' with an electrically operated lift. The concept of the 'deadman', which was shown to help reduce musculoskeletal exposures during ceiling installation, can be used to fabricate a permanent ergonomic tool to support the ceiling drywall panel. Copyright © 2016 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  12. Peak effect in twinned superconductors

    International Nuclear Information System (INIS)

    Larkin, A.I.; Marchetti, M.C.; Vinokur, V.M.

    1995-01-01

    A sharp maximum in the critical current J c as a function of temperature just below the melting point of the Abrikosov flux lattice has recently been observed in both low- and high-temperature superconductors. This peak effect is strongest in twinned crystals for fields aligned with the twin planes. We propose that this peak signals the breakdown of the collective pinning regime and the crossover to strong pinning of single vortices on the twin boundaries. This crossover is very sharp and can account for the steep drop of the differential resistivity observed in experiments. copyright 1995 The American Physical Society

  13. Glass Ceiling Converted Into Glass Transparency: A Study On The Factors Making Women Executives Successful In The Indian Banking Sector

    OpenAIRE

    Sachdeva, Dr Geeta

    2014-01-01

    Economic reforms in the Indian economy along with gradual opening up of a conservative society to a modern society preceded breaking the glass ceiling or conversion Glass ceiling into a Glass Transparency in the Indian Banking Sector. This is backed by a recent study of 240 top Indian companies by EMA Partners, the global executive-search firm, which says more than a half of India's women chief executives are accounted for by the banking and financial services industry. This paper studie...

  14. Effects of Glass Ceiling on Women Career Development in Private Sector Organizations – Case of Sri Lanka

    OpenAIRE

    Bombuwela P. M.; De Alwis A. Chamaru

    2013-01-01

    The study was entirely designed by centering the focal problem of the effect of Glass Ceiling on Women Career Development. The overall study was structure based on the conceptual framework built up using the information of literature survey. The study was conducted with the aim of obtaining the following objective. That is “To find out the Effect of Glass Ceiling on Women Career Development with regard to female executive level employees who are working in privatesector organizations.” At the...

  15. Hubbert's Peak -- A Physicist's View

    Science.gov (United States)

    McDonald, Richard

    2011-04-01

    Oil, as used in agriculture and transportation, is the lifeblood of modern society. It is finite in quantity and will someday be exhausted. In 1956, Hubbert proposed a theory of resource production and applied it successfully to predict peak U.S. oil production in 1970. Bartlett extended this work in publications and lectures on the finite nature of oil and its production peak and depletion. Both Hubbert and Bartlett place peak world oil production at a similar time, essentially now. Central to these analyses are estimates of total ``oil in place'' obtained from engineering studies of oil reservoirs as this quantity determines the area under the Hubbert's Peak. Knowing the production history and the total oil in place allows us to make estimates of reserves, and therefore future oil availability. We will then examine reserves data for various countries, in particular OPEC countries, and see if these data tell us anything about the future availability of oil. Finally, we will comment on synthetic oil and the possibility of carbon-neutral synthetic oil for a sustainable future.

  16. Prediction of peak overlap in NMR spectra

    International Nuclear Information System (INIS)

    Hefke, Frederik; Schmucki, Roland; Güntert, Peter

    2013-01-01

    Peak overlap is one of the major factors complicating the analysis of biomolecular NMR spectra. We present a general method for predicting the extent of peak overlap in multidimensional NMR spectra and its validation using both, experimental data sets and Monte Carlo simulation. The method is based on knowledge of the magnetization transfer pathways of the NMR experiments and chemical shift statistics from the Biological Magnetic Resonance Data Bank. Assuming a normal distribution with characteristic mean value and standard deviation for the chemical shift of each observable atom, an analytic expression was derived for the expected overlap probability of the cross peaks. The analytical approach was verified to agree with the average peak overlap in a large number of individual peak lists simulated using the same chemical shift statistics. The method was applied to eight proteins, including an intrinsically disordered one, for which the prediction results could be compared with the actual overlap based on the experimentally measured chemical shifts. The extent of overlap predicted using only statistical chemical shift information was in good agreement with the overlap that was observed when the measured shifts were used in the virtual spectrum, except for the intrinsically disordered protein. Since the spectral complexity of a protein NMR spectrum is a crucial factor for protein structure determination, analytical overlap prediction can be used to identify potentially difficult proteins before conducting NMR experiments. Overlap predictions can be tailored to particular classes of proteins by preparing statistics from corresponding protein databases. The method is also suitable for optimizing recording parameters and labeling schemes for NMR experiments and improving the reliability of automated spectra analysis and protein structure determination.

  17. Ceiling effect of online user interests for the movies

    Science.gov (United States)

    Ni, Jing; Zhang, Yi-Lu; Hu, Zhao-Long; Song, Wen-Jun; Hou, Lei; Guo, Qiang; Liu, Jian-Guo

    2014-05-01

    Online users' collective interests play an important role for analyzing the online social networks and personalized recommendations. In this paper, we introduce the information entropy to measure the diversity of the user interests. We empirically analyze the information entropy of the objects selected by the users with the same degree in both the MovieLens and Netflix datasets. The results show that as the user degree increases, the entropy increases from the lowest value at first to the highest value and then begins to fall, which indicates that the interests of the small-degree and large-degree users are more centralized, while the interests of normal users are more diverse. Furthermore, a null model is proposed to compare with the empirical results. In a null model, we keep the number of users and objects as well as the user degrees unchangeable, but the selection behaviors are totally random in both datasets. Results show that the diversity of the majority of users in the real datasets is higher than that the random case, with the exception of the diversity of only a fraction of small-degree users. That may because new users just like popular objects, while with the increase of the user experiences, they quickly become users of broad interests. Therefore, small-degree users' interests are much easier to predict than the other users', which may shed some light for the cold-start problem.

  18. SPANISH PEAKS PRIMITIVE AREA, MONTANA.

    Science.gov (United States)

    Calkins, James A.; Pattee, Eldon C.

    1984-01-01

    A mineral survey of the Spanish Peaks Primitive Area, Montana, disclosed a small low-grade deposit of demonstrated chromite and asbestos resources. The chances for discovery of additional chrome resources are uncertain and the area has little promise for the occurrence of other mineral or energy resources. A reevaluation, sampling at depth, and testing for possible extensions of the Table Mountain asbestos and chromium deposit should be undertaken in the light of recent interpretations regarding its geologic setting.

  19. Neurofeedback training for peak performance

    OpenAIRE

    Marek Graczyk; Maria Pąchalska; Artur Ziółkowski; Grzegorz Mańko; Beata Łukaszewska; Kazimierz Kochanowicz; Andrzej Mirski; Iurii D. Kropotov

    2014-01-01

    [b]aim[/b]. One of the applications of the Neurofeedback methodology is peak performance in sport. The protocols of the neurofeedback are usually based on an assessment of the spectral parameters of spontaneous EEG in resting state conditions. The aim of the paper was to study whether the intensive neurofeedback training of a well-functioning Olympic athlete who has lost his performance confidence after injury in sport, could change the brain functioning reflected in changes in spontaneou...

  20. Evaluation of concurrent peak responses

    International Nuclear Information System (INIS)

    Wang, P.C.; Curreri, J.; Reich, M.

    1983-01-01

    This report deals with the problem of combining two or more concurrent responses which are induced by dynamic loads acting on nuclear power plant structures. Specifically, the acceptability of using the square root of the sum of the squares (SRSS) value of peak values as the combined response is investigated. Emphasis is placed on the establishment of a simplified criterion that is convenient and relatively easy to use by design engineers

  1. Finding two-dimensional peaks

    International Nuclear Information System (INIS)

    Silagadze, Z.K.

    2007-01-01

    Two-dimensional generalization of the original peak finding algorithm suggested earlier is given. The ideology of the algorithm emerged from the well-known quantum mechanical tunneling property which enables small bodies to penetrate through narrow potential barriers. We merge this 'quantum' ideology with the philosophy of Particle Swarm Optimization to get the global optimization algorithm which can be called Quantum Swarm Optimization. The functionality of the newborn algorithm is tested on some benchmark optimization problems

  2. Gamma-Ray Peak Integration: Accuracy and Precision

    International Nuclear Information System (INIS)

    Richard M. Lindstrom

    2000-01-01

    The accuracy of singlet gamma-ray peak areas obtained by a peak analysis program is immaterial. If the same algorithm is used for sample measurement as for calibration and if the peak shapes are similar, then biases in the integration method cancel. Reproducibility is the only important issue. Even the uncertainty of the areas computed by the program is trivial because the true standard uncertainty can be experimentally assessed by repeated measurements of the same source. Reproducible peak integration was important in a recent standard reference material certification task. The primary tool used for spectrum analysis was SUM, a National Institute of Standards and Technology interactive program to sum peaks and subtract a linear background, using the same channels to integrate all 20 spectra. For comparison, this work examines other peak integration programs. Unlike some published comparisons of peak performance in which synthetic spectra were used, this experiment used spectra collected for a real (though exacting) analytical project, analyzed by conventional software used in routine ways. Because both components of the 559- to 564-keV doublet are from 76 As, they were integrated together with SUM. The other programs, however, deconvoluted the peaks. A sensitive test of the fitting algorithm is the ratio of reported peak areas. In almost all the cases, this ratio was much more variable than expected from the reported uncertainties reported by the program. Other comparisons to be reported indicate that peak integration is still an imperfect tool in the analysis of gamma-ray spectra

  3. Drivers of peak sales for pharmaceutical brands

    NARCIS (Netherlands)

    Fischer, Marc; Leeflang, Peter S. H.; Verhoef, Peter C.

    2010-01-01

    Peak sales are an important metric in the pharmaceutical industry. Specifically, managers are focused on the height-of-peak-sales and the time required achieving peak sales. We analyze how order of entry and quality affect the level of peak sales and the time-to-peak-sales of pharmaceutical brands.

  4. Gamma-ray peak shapes from cadmium zinc telluride detectors

    Energy Technology Data Exchange (ETDEWEB)

    Namboodiri, M.N.; Lavietes, A.D.; McQuaid, J.H.

    1996-09-01

    We report the results of a study of the peak shapes in the gamma spectra measured using several 5 x 5 x 5 mm{sup 3} cadmium zinc telluride (CZT) detectors. A simple parameterization involving a Gaussian and an exponential low energy tail describes the peak shapes sell. We present the variation of the parameters with gamma energy. This type of information is very useful in the analysis of complex gamma spectra consisting of many peaks.

  5. Energy peaks: A high energy physics outlook

    Science.gov (United States)

    Franceschini, Roberto

    2017-12-01

    Energy distributions of decay products carry information on the kinematics of the decay in ways that are at the same time straightforward and quite hidden. I will review these properties and discuss their early historical applications, as well as more recent ones in the context of (i) methods for the measurement of masses of new physics particle with semi-invisible decays, (ii) the characterization of Dark Matter particles produced at colliders, (iii) precision mass measurements of Standard Model particles, in particular of the top quark. Finally, I will give an outlook of further developments and applications of energy peak method for high energy physics at colliders and beyond.

  6. Dropped Ceiling

    OpenAIRE

    Tabet, Rayyane

    2012-01-01

    On December 2nd 1950 the first drop of Saudi oil arrived to Lebanon via the newly constructed Trans-Arabian Pipeline, the world's longest pipeline and the largest American private investment in a foreign land. The 30inch wide structure which spanned 1213 kilometers passing through Saudi Arabia, Jordan, and Syria to end in Lebanon had required 3 years of planning and surveying, 2 years of installation, the fabrication of 256,000 tons of steel tubes, the employment of 30,000 workers, the ratifi...

  7. Is there still a glass ceiling for women in academic surgery?

    Science.gov (United States)

    Zhuge, Ying; Kaufman, Joyce; Simeone, Diane M; Chen, Herbert; Velazquez, Omaida C

    2011-04-01

    Despite the dramatically increased entry of women into general surgery and surgical subspecialties, traditionally male-dominated fields, there remains a gross under-representation of women in the leadership positions of these departments. Women begin their careers with fewer academic resources and tend to progress through the ranks slower than men. Female surgeons also receive significantly lower salaries than their male counterparts and are more vulnerable to discrimination, both obvious and covert. Although some argue that female surgeons tend to choose their families over careers, studies have actually shown that women are as eager as men to assume leadership positions, are equally qualified for these positions as men, and are as good as men at leadership tasks.Three major constraints contribute to the glass-ceiling phenomenon: traditional gender roles, manifestations of sexism in the medical environment, and lack of effective mentors. Gender roles contribute to unconscious assumptions that have little to do with actual knowledge and abilities of an individuals and they negatively influence decision-making when it comes to promotions. Sexism has many forms, from subtle to explicit forms, and some studies show that far more women report being discriminately against than do men. There is a lack of same-sex mentors and role models for women in academic surgery, thereby isolating female academicians further. This review summarizes the manifestation of the glass-ceiling phenomenon, identifies some causes of these inequalities, and proposes different strategies for continuing the advancement of women in academic surgery and to shatter the glass ceiling.

  8. Women and work : an exploratory study on problems and perspectives relating to the apparent inability of women teachers to break through the glass ceiling

    OpenAIRE

    2012-01-01

    M.B.A. The aim of this research is to determine whether a glass ceiling does exist in education, and if so, possible reasons why women teachers fail to break through the so-called "glass ceiling". Objectives The objectives identified include the following: To determine historical perspectives on women and work To explore the incidence of glass ceilings To ascertain the value the Department of Education places on women teachers To determine by means of questionnaires whether there is a 'gla...

  9. Assessing peak aerobic capacity in Dutch law enforcement officers

    Directory of Open Access Journals (Sweden)

    Harriet Wittink

    2015-06-01

    Full Text Available Objectives: To cross-validate the existing peak rate of oxygen consumption (VO2peak prediction equations in Dutch law enforcement officers and to determine whether these prediction equations can be used to predict VO2peak for groups and in a single individual. A further objective was to report normative absolute and relative VO2peak values of a sample of law enforcement officers in the Netherlands. Material and Methods: The peak rate of oxygen consumption (ml×kg–1×min–1 was measured using a maximal incremental bicycle test in 1530 subjects, including 1068 male and 461 female police officers. Validity of the prediction equations for groups was assessed by comparing predicted VO2peak with measured VO2peak using paired t-tests. For individual differences limits of agreement (LoA were calculated. Equations were considered valid for individuals when the difference between measured and predicted VO2peak did not exceed ±1 metabolic equivalent (MET in 95% of individuals. Results: None of the equations met the validity criterion of 95% of individuals having ±1 MET difference or less than the measured value. Limits of agreement (LoAs were large in all predictions. At the individual level, none of the equations were valid predictors of VO2peak (ml×kg–1×min–1. Normative values for Dutch law enforcement officers were presented. Conclusions: Substantial differences between measured and predicted VO2peak (ml×kg–1×min–1 were found. Most tested equations were invalid predictors of VO2peak at group level and all were invalid at individual levels.

  10. Experimental evaluation of heat transfer coefficients between radiant ceiling and room

    DEFF Research Database (Denmark)

    Causone, Francesco; Corgnati, Stefano P.; Filippi, Marco

    2009-01-01

    The heat transfer coefficients between radiant surfaces and room are influenced by several parameters: surfaces temperature distributions, internal gains, air movements. The aim of this paper is to evaluate the heat transfer coefficients between radiant ceiling and room in typical conditions...... of occupancy of an office or residential building. Internal gains were therefore simulated using heated cylinders and heat losses using cooled surfaces. Evaluations were developed by means of experimental tests in an environmental chamber. Heat transfer coefficient may be expressed separately for radiation...

  11. Social impact of air pollution abatement. Societal cost benefit analysis of possible National Emission Ceilings

    International Nuclear Information System (INIS)

    Doenszelmann, C.E.P.; De Bruyn, S.M.; Korteland, M.H.; De Jong, F.; Sevenster, M.N.; Briene, M.; Wienhoven, M.; Bovens, J.

    2008-07-01

    In 2008, the European Commission will launch new proposals for revision of the NEC guideline (2001/81/EG) in which new emission ceilings are proposed for the year 2020. In order to determine which stand the Netherlands should take during the negotiations, the Dutch Ministry of Economic Affairs (also on behalf of the Ministry of Agriculture, Nature and Food Quality) asked CE Delft and Ecorys to conduct a societal cost benefit analysis in collaboration with the Environmental Assessment Agency. This report describes the results of the analysis of two alternative NEC targets for 2020. [mk] [nl

  12. Field evaluation of performance of radiant heating/cooling ceiling panel system

    DEFF Research Database (Denmark)

    Li, Rongling; Yoshidomi, Togo; Ooka, Ryozo

    2015-01-01

    heating/coolingceiling panel system is used. However, no standard exists for the in situ performance evaluation of radiantheating/cooling ceiling systems; furthermore, no published database is available for comparison. Thus,this study aims to not only clarify the system performance but also to share our...... experience and our resultsfor them to serve as a reference for other similar projects. Here, the system performance in relation toits heating/cooling capacity and thermal comfort has been evaluated. The heat transfer coefficient fromwater to room was 3.7 W/(m2K) and 4.8 W/(m2K) for heating and cooling cases...

  13. Maximizing the lightshelf performance by interaction between lightshelf geometries and a curved ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Freewan, Ahmed A. [Jordan University of Science and Technology, Irbid 22110 (Jordan)

    2010-08-15

    The interaction between different lightshelf geometries combined with a curved ceiling was investigated using radiance to maximize the daylight performance of a lightshelf. Two main performance parameters were investigated; illuminance level and distribution uniformity in a large space located in a sub-tropical climate region like Jordan. It was found that a curved lightshelf could improve the daylight level by 10% compared to a horizontal lightshelf. A curved lightshelf help to bounce more daylight deep into a space thus improve the illuminance level and uniformity level. The best lightshelf shapes found are curved and chamfered lightshelves compared to horizontal lightshelves. (author)

  14. Use of perforated acoustic panels as supply air diffusers in diffuse ceiling ventilation systems

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Kazemi, Seyed Hossein; Ardkapan, Siamak Rahimi

    Ventilation is needed for diluting and removing the contaminants, odour and excess heat from the building interior. It is important that the inhabitants perceive the ventilated spaces as comfortable. Therefore, the supply air should reach all parts of the occupied zones. Troldtekt has been...... manufacturing perforated acoustic panels for the last 13 years. The panels can be used not only in applications related to acoustics but also as low pressure drop supply air diffusers, particularly in diffuse ceiling ventilation systems. The present study verifies on a theoretically level the performance...

  15. Field Study of Diffuse Ceiling Ventilation Performance in a Landscape Office

    DEFF Research Database (Denmark)

    Zukowska-Tejsen, Daria; Wolsing, Marie; Grysbæk, Malene

    2016-01-01

    show that diffuse ceiling ventilation has substantial potential for landscape office applications because it can provide important cooling capacity while maintaining an acceptable comfort level in the occupied zone. It does not generate draught in the occupied zone even at large temperature differences...... between supply and exhaust and great air change rates, while the same design parameters caused risk of draught in many points in the case with mixing ventilation. Good mixing in the occupied zone in case of both systems resulted in only small vertical temperature gradients. The results from the study...

  16. The Relationship between Glass Ceiling Barriers to Woman and Perceived Organizational Justice in Working Life

    OpenAIRE

    Özyer, Kubilay; Azizoğlu, Öznur

    2014-01-01

    Women are participating more and more to the working life nowadays. But they couldn’t adequately take part in high management positions. There are too many reasons which effect this case. Especially; in some research it suggested that women couldn’t go beyond to a barrier, “glass ceiling”, which is an invisible obstacle for women, and they have to work under it. For these reason; in this study firstly, the terms of glass ceiling obstacle to women and perceived organizational justice and the i...

  17. Is a Widening Gender Wage Gap Necessarily Caused by a Glass Ceiling?

    OpenAIRE

    Staveren, Irene

    2012-01-01

    textabstractContrary to what is generally assumed, the gender wage gap and the glass ceiling may not necessarily be positively related. An exploratory analysis of aggregate public service personnel data for Uganda shows that the gender wage gap is small at the middle level of management, whereas it is twice as high at the top. At the same time, the share of women in top positions appears to be twice as high as at the middle ranks. Hence, it seems that in the context of a very patriarchal cult...

  18. Spatial peak-load pricing

    International Nuclear Information System (INIS)

    Arellano, M. Soledad; Serra, Pablo

    2007-01-01

    This article extends the traditional electricity peak-load pricing model to include transmission costs. In the context of a two-node, two-technology electric power system, where suppliers face inelastic demand, we show that when the marginal plant is located at the energy-importing center, generators located away from that center should pay the marginal capacity transmission cost; otherwise, consumers should bear this cost through capacity payments. Since electric power transmission is a natural monopoly, marginal-cost pricing does not fully cover costs. We propose distributing the revenue deficit among users in proportion to the surplus they derive from the service priced at marginal cost. (Author)

  19. Evaluation of Various Retrofitting Concepts of Building Envelope for Offices Equipped with Large Radiant Ceiling Panels by Dynamic Simulations

    Directory of Open Access Journals (Sweden)

    Sabina Jordan

    2015-09-01

    Full Text Available In order to achieve significant savings in energy and an improved level of thermal comfort in retrofitted existing buildings, specific retrofitting concepts that combine new technologies and design need to be developed and implemented. Large radiant surfaces systems are now among the most promising future technologies to be used both in retrofitted and in new low-energy buildings. These kinds of systems have been the topic of several studies dealing with thermal comfort and energy utilization, but some specific issues concerning their possible use in various concepts for retrofitting are still poorly understood. In the present paper, some results of dynamic simulations, with the transient system simulation tool (TRNSYS model, of the retrofitted offices equipped with radiant ceiling panels are presented and thoroughly analysed. Based on a precise comparison of the results of these simulations with actual measurements in the offices, certain input data for the model were added, so that the model was consequently validated. The model was then applied to the evaluation of various concepts of building envelopes for office retrofitting. By means of dynamic simulations of indoor environment it was possible to determine the benefits and limitations of individual retrofitting concepts. Some specific parameters, which are relevant to these concepts, were also identified.

  20. The measurement of change in functional ability: dealing with attrition and the floor/ceiling effect

    DEFF Research Database (Denmark)

    Holstein, Bjørn E; Avlund, Kirsten; Due, Pernille

    2006-01-01

    , functional ability at baseline, relative wealth, social network, self-rated health, and life-satisfaction. Inclusion of the dead in statistical models for the study of change in functional ability reduced the attrition problem. A logistic model for paired observations of functional ability at two points...

  1. Peak effect in surface resistance at microwave frequencies in Dy ...

    Indian Academy of Sciences (India)

    In the measurements at both frequencies the induced microwave current was always less than the critical current of the films. The reason for observation of this peak effect in these films has been explained in our earlier publication [5]. Comparing figures 1 and 2, it is observed that the peaks in sample S1 are broader and.

  2. Identification of peaks in multidimensional coincidence {gamma}-ray spectra

    Energy Technology Data Exchange (ETDEWEB)

    Morhac, Miroslav E-mail: fyzimiro@savba.sk; Kliman, Jan; Matousek, Vladislav; Veselsky, Martin; Turzo, Ivan

    2000-03-21

    In the paper a new algorithm to find peaks in two, three and multidimensional spectra, measured in large multidetector {gamma}-ray arrays, is derived. Given the dimension m, the algorithm is selective to m-fold coincidence peaks. It is insensitive to intersections of lower-fold coincidences, hereinafter called ridges.

  3. Identification of peaks in multidimensional coincidence γ-ray spectra

    International Nuclear Information System (INIS)

    Morhac, Miroslav; Kliman, Jan; Matousek, Vladislav; Veselsky, Martin; Turzo, Ivan

    2000-01-01

    In the paper a new algorithm to find peaks in two, three and multidimensional spectra, measured in large multidetector γ-ray arrays, is derived. Given the dimension m, the algorithm is selective to m-fold coincidence peaks. It is insensitive to intersections of lower-fold coincidences, hereinafter called ridges

  4. The dislocation-internal friction peak γ in tantalum

    International Nuclear Information System (INIS)

    Baur, J.; Benoit, W.; Schultz, H.

    1989-01-01

    Torsion-pendulum measurements were carried out on high-purity single crystal specimens of tantalum, having extremely low oxygen contents ( 2 peak, which appears close to γ is small traces of oxygen are presents. The γ 2 peak was formerly explained as a ''dislocation-enhanced Snoek peak''. The γ peak recovers at the peak temperature, whereas the γ 2 peak is more stable. On the basis of their results, and making use of earlier investigations of Rodrian and Schultz, the authors suggest that γ 2 is modified γ relaxation, related to screw-dislocation segments, stabilized by oxygen-decorated kinks. The stability of the γ 2 peak allows an accurate determination of the activation energy, found to be 1.00 +- 0.03 eV. This value is distinctly lower than the activation energy of the oxygen Snoek effect (1.10 eV) and is related here to the mechanism of ''kink-pair formation'' in screw dislocations, as the original γ peak. The numerical value is compatible with recent values derived from flow-stress measurements. The peak γ 2 shows increasing stability with increasing oxygen content. This is explained by single- and multi-decorated kinks

  5. Acquisition of peak responding: what is learned?

    Science.gov (United States)

    Balci, Fuat; Gallistel, Charles R; Allen, Brian D; Frank, Krystal M; Gibson, Jacqueline M; Brunner, Daniela

    2009-01-01

    We investigated how the common measures of timing performance behaved in the course of training on the peak procedure in C3H mice. Following fixed interval (FI) pre-training, mice received 16 days of training in the peak procedure. The peak time and spread were derived from the average response rates while the start and stop times and their relative variability were derived from a single-trial analysis. Temporal precision (response spread) appeared to improve in the course of training. This apparent improvement in precision was, however, an averaging artifact; it was mediated by the staggered appearance of timed stops, rather than by the delayed occurrence of start times. Trial-by-trial analysis of the stop times for individual subjects revealed that stops appeared abruptly after three to five sessions and their timing did not change as training was prolonged. Start times and the precision of start and stop times were generally stable throughout training. Our results show that subjects do not gradually learn to time their start or stop of responding. Instead, they learn the duration of the FI, with robust temporal control over the start of the response; the control over the stop of response appears abruptly later.

  6. Measuring fire size in tunnels

    International Nuclear Information System (INIS)

    Guo, Xiaoping; Zhang, Qihui

    2013-01-01

    A new measure of fire size Q′ has been introduced in longitudinally ventilated tunnel as the ratio of flame height to the height of tunnel. The analysis in this article has shown that Q′ controls both the critical velocity and the maximum ceiling temperature in the tunnel. Before the fire flame reaches tunnel ceiling (Q′ 1.0), Fr approaches a constant value. This is also a well-known phenomenon in large tunnel fires. Tunnel ceiling temperature shows the opposite trend. Before the fire flame reaches the ceiling, it increases very slowly with the fire size. Once the flame has hit the ceiling of tunnel, temperature rises rapidly with Q′. The good agreement between the current prediction and three different sets of experimental data has demonstrated that the theory has correctly modelled the relation among the heat release rate of fire, ventilation flow and the height of tunnel. From design point of view, the theoretical maximum of critical velocity for a given tunnel can help to prevent oversized ventilation system. -- Highlights: • Fire sizing is an important safety measure in tunnel design. • New measure of fire size a function of HRR of fire, tunnel height and ventilation. • The measure can identify large and small fires. • The characteristics of different fire are consistent with observation in real fires

  7. Women's health and women's leadership in academic medicine: hitting the same glass ceiling?

    Science.gov (United States)

    Carnes, Molly; Morrissey, Claudia; Geller, Stacie E

    2008-11-01

    The term "glass ceiling" refers to women's lack of advancement into leadership positions despite no visible barriers. The term has been applied to academic medicine for over a decade but has not previously been applied to the advancement of women's health. This paper discusses (1) the historical linking of the advances in women's health with women's leadership in academic medicine, (2) the slow progress of women into leadership in academic medicine, and (3) indicators that the advancement of women's health has stalled. We make the case that deeply embedded unconscious gender-based biases and assumptions underpin the stalled advancement of women on both fronts. We conclude with recommendations to promote progress beyond the apparent glass ceiling that is preventing further advancement of women's health and women leaders. We emphasize the need to move beyond "fixing the women" to a systemic, institutional approach that acknowledges and addresses the impact of unconscious, gender-linked biases that devalue and marginalize women and issues associated with women, such as their health.

  8. An Integrated Numerical and Experimental Analysis for Enhancing the Performance of the Hidden Ceiling Fan

    Directory of Open Access Journals (Sweden)

    Sheam-Chyun Lin

    2014-02-01

    Full Text Available Since the inlet and outlet of hidden ceiling fan are almost located at the same Plane; thus, an improper housing may cause inhale-return phenomenon which significantly affects its power consumption and performance. In this study, a comprehensive investigation by numerical and experimental techniques was used to predict and identify the flow pattern, airflow rate, efficiency, and noise for ceiling fans with different design parameters. The results showed that the unique inhale-return phenomenon happens for an inappropriate housing. Several key parameters, such as fan guard, housing ring, inlet-to-outlet area ratio, and blockage height, are evaluated for finding out the criterion to avoid the inhale-return flow. Consequently the study finds that fan guard changes the airflow to a wider distribution with a lower velocity. A minimum blockage distance and a maximum height of ring-plate are set at 80 mm and 30 mm, respectively. Also, it is suggested that the inlet area must be bigger than the outlet area. Moreover, all the parameters show the same trend under various rotational speeds. In conclusion, this systematic investigation not only provides the fan engineer's design ability to avoid the inhale-return phenomenon, but also the predicting capability on its aerodynamic and acoustic performances.

  9. The Spanish gasoline market: From ceiling regulation to open market pricing

    International Nuclear Information System (INIS)

    Contin, I.; Correlje, A.; Huerta, E.

    1999-01-01

    This paper examines the evolution of the Spanish gasoline market from the abolition of the state oil monopoly (January 1993) to complete liberalization (October 1998). With the restructuring of the Spanish oil sector during the 1980s and early 1990s, a highly concentrated oligopoly emerged in the automotive fuels market. A system of price ceilings replaced the state administered prices in July 1990. Since then, new domestic and foreign operators have entered the market, particularly along the coast, near import terminals. Prices went up and then declined. These developments can be explained by an interplay of factors such as: the gradual decline in co-operation among the Spanish firms; the loss of market share of the largest of these, Repsol; the entry of independent operators and supermarkets; and the impact of the ceiling price system. By mid-1998 this system was abolished as the government considered it an impediment to further market liberalization. However, some crucial barriers to the entry of new suppliers remain

  10. Geomorphometric analysis of cave ceiling channels mapped with 3-D terrestrial laser scanning

    Science.gov (United States)

    Gallay, Michal; Hochmuth, Zdenko; Kaňuk, Ján; Hofierka, Jaroslav

    2016-05-01

    The change of hydrological conditions during the evolution of caves in carbonate rocks often results in a complex subterranean geomorphology, which comprises specific landforms such as ceiling channels, anastomosing half tubes, or speleothems organized vertically in different levels. Studying such complex environments traditionally requires tedious mapping; however, this is being replaced with terrestrial laser scanning technology. Laser scanning overcomes the problem of reaching high ceilings, providing new options to map underground landscapes with unprecedented level of detail and accuracy. The acquired point cloud can be handled conveniently with dedicated software, but applying traditional geomorphometry to analyse the cave surface is limited. This is because geomorphometry has been focused on parameterization and analysis of surficial terrain. The theoretical and methodological concept has been based on two-dimensional (2-D) scalar fields, which are sufficient for most cases of the surficial terrain. The terrain surface is modelled with a bivariate function of altitude (elevation) and represented by a raster digital elevation model. However, the cave is a 3-D entity; therefore, a different approach is required for geomorphometric analysis. In this paper, we demonstrate the benefits of high-resolution cave mapping and 3-D modelling to better understand the palaeohydrography of the Domica cave in Slovakia. This methodological approach adopted traditional geomorphometric methods in a unique manner and also new methods used in 3-D computer graphics, which can be applied to study other 3-D geomorphological forms.

  11. Statistical analysis of uncertainties of gamma-peak identification and area calculation in particulate air-filter environment radionuclide measurements using the results of a Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) organized intercomparison, Part I: Assessment of reliability and uncertainties of isotope detection and energy precision using artificial spiked test spectra, Part II: Assessment of the true type I error rate and the quality of peak area estimators in relation to type II errors using large numbers of natural spectra

    International Nuclear Information System (INIS)

    Zhang, W.; Zaehringer, M.; Ungar, K.; Hoffman, I.

    2008-01-01

    In this paper, the uncertainties of gamma-ray small peak analysis have been examined. As the intensity of a gamma-ray peak approaches its detection decision limit, derived parameters such as centroid channel energy, peak area, peak area uncertainty, baseline determination, and peak significance are statistically sensitive. The intercomparison exercise organized by the CTBTO provided an excellent opportunity for this to be studied. Near background levels, the false-positive and false-negative peak identification frequencies in artificial test spectra have been compared to statistically predictable limiting values. In addition, naturally occurring radon progeny were used to compare observed variance against nominal uncertainties. The results infer that the applied fit algorithms do not always represent the best estimator. Understanding the statistically predicted peak-finding limit is important for data evaluation and analysis assessment. Furthermore, these results are useful to optimize analytical procedures to achieve the best results

  12. Proposal for the award of an industrial support contract for paintwork, false ceilings, plasterwork and false floors at CERN

    CERN Document Server

    2006-01-01

    This document concerns the award of a contract for paintwork, false ceilings, plasterwork and false floors at CERN. The Finance Committee is invited to agree to the negotiation of a contract with the firm PREZIOSO (FR), the lowest bidder, for the provision of paintwork, false ceilings, plasterwork and false floors at CERN for a period of three years for a total amount not exceeding 538 419 euros (830 381 Swiss francs), not subject to revision for the first two years. The contract will include options for two one-year extensions beyond the initial threeyear period.

  13. Career Barriers for Women Executives and the Glass Ceiling Syndrome: The Case Study Comparison between French and Turkish Women Executives

    OpenAIRE

    Akpinar-Sposito, Cansu

    2013-01-01

    International audience; The situation where gender pay gaps are typically wider at the top of the wage distribution is known as the 'glass ceiling'. It is one of the most compelling metaphors recently used for analyzing inequality between men and women in the workplace, in order to describe a barrier to further advancement once women have attained a certain level. The general-case glass ceiling hypothesis states that not only is it more difficult for women than for men to be promoted up level...

  14. From the glass door to the glass ceiling: An analysis of the gender wage gap by age groups

    OpenAIRE

    Elena Dalla Chiara; Eleonora Matteazzi; Ilaria Petrarca

    2014-01-01

    Using 2009 EU-SILC data for France, Italy, the Netherlands and the United Kingdom, we decompose the gender wage gap for prime age workers. We adopt an age group approach to identify when and how the glass door and the glass ceiling effects arise and their persistency over time. The empirical results verify that the raw gender wage gap increases with age. In all considered countries, the glass ceiling effect is completely realized by the age of 30 and increases over time. French, Italian and B...

  15. Peak experiences of psilocybin users and non-users.

    Science.gov (United States)

    Cummins, Christina; Lyke, Jennifer

    2013-01-01

    Maslow (1970) defined peak experiences as the most wonderful experiences of a person's life, which may include a sense of awe, well-being, or transcendence. Furthermore, recent research has suggested that psilocybin can produce experiences subjectively rated as uniquely meaningful and significant (Griffiths et al. 2006). It is therefore possible that psilocybin may facilitate or change the nature of peak experiences in users compared to non-users. This study was designed to compare the peak experiences of psilocybin users and non-users, to evaluate the frequency of peak experiences while under the influence of psilocybin, and to assess the perceived degree of alteration of consciousness during these experiences. Participants were recruited through convenience and snowball sampling from undergraduate classes and at a musical event. Participants were divided into three groups, those who reported a peak experience while under the influence of psilocybin (psilocybin peak experience: PPE), participants who had used psilocybin but reported their peak experiences did not occur while they were under the influence of psilocybin (non-psilocybin peak experience: NPPE), and participants who had never used psilocybin (non-user: NU). A total of 101 participants were asked to think about their peak experiences and complete a measure evaluating the degree of alteration of consciousness during that experience. Results indicated that 47% of psilocybin users reported their peak experience occurred while using psilocybin. In addition, there were significant differences among the three groups on all dimensions of alteration of consciousness. Future research is necessary to identify factors that influence the peak experiences of psilocybin users in naturalistic settings and contribute to the different characteristics of peak experiences of psilocybin users and non-users.

  16. A Measurement of the Forward-Backward Asymmetry of $e^{+}e^{-} \\to c\\overline{c}$ and $e^{+}e^{-} \\to b\\overline{b}$ at Centre-of-Mass Energies on and near the $Z^{0}$ Peak using $D^{*\\pm}$ Mesons

    CERN Document Server

    Akers, R J; Allison, J; Anderson, K J; Arcelli, S; Astbury, Alan; Axen, D A; Azuelos, Georges; Baines, J T M; Ball, A H; Banks, J; Barlow, R J; Barnett, S; Bartoldus, R; Batley, J Richard; Beaudoin, G; Beck, A; Beck, G A; Becker, J; Beeston, C; Behnke, T; Bell, K W; Bella, G; Bentkowski, P; Berlich, P; Bethke, Siegfried; Biebel, O; Bloodworth, Ian J; Bock, P; Boden, B; Bosch, H M; Boutemeur, M; Breuker, Horst; Bright-Thomas, P G; Brown, R M; Buijs, A; Burckhart, Helfried J; Burgard, C; Capiluppi, P; Carnegie, R K; Carter, A A; Carter, J R; Chang, C Y; Charlton, D G; Chu, S L; Clarke, P E L; Clayton, J C; Cohen, I; Conboy, J E; Cooper, M; Coupland, M; Cuffiani, M; Dado, S; Dallavalle, G M; De Jong, S; del Pozo, L A; Deng, H; Dieckmann, A; Dittmar, Michael; Dixit, M S; do Couto e Silva, E; Duboscq, J E; Duchovni, E; Duckeck, G; Duerdoth, I P; Dumas, D J P; Elcombe, P A; Estabrooks, P G; Etzion, E; Evans, H G; Fabbri, Franco Luigi; Fabbro, B; Fierro, M; Fincke-Keeler, Margret; Fischer, H M; Fong, D G; Foucher, M; Gaidot, A; Gary, J W; Gascon, J; Geddes, N I; Geich-Gimbel, C; Gensler, S W; Gentit, F X; Giacomelli, G; Giacomelli, R; Gibson, V; Gibson, W R; Gillies, James D; Goldberg, J; Gingrich, D M; Goodrick, M J; Gorn, W; Grandi, C; Grant, F C; Hagemann, J; Hanson, G G; Hansroul, M; Hargrove, C K; Harrison, P F; Hart, J; Hattersley, P M; Hauschild, M; Hawkes, C M; Heflin, E; Hemingway, Richard J; Herten, G; Heuer, R D; Hill, J C; Hillier, S J; Hilse, T; Hinshaw, D A; Hobbs, J D; Hobson, P R; Hochman, D; Homer, R James; Honma, A K; Hughes-Jones, R E; Humbert, R; Igo-Kemenes, P; Ihssen, H; Imrie, D C; Janissen, A C; Jawahery, A; Jeffreys, P W; Jeremie, H; Jimack, Martin Paul; Jones, M; Jones, R W L; Jovanovic, P; Jui, C; Karlen, D A; Kawagoe, K; Kawamoto, T; Keeler, Richard K; Kellogg, R G; Kennedy, B W; King, J; Kluth, S; Kobayashi, T; Koetke, D S; Kokott, T P; Komamiya, S; Kral, J F; Kowalewski, R V; Von Krogh, J; Kroll, J; Kyberd, P; Lafferty, G D; Lafoux, H; Lahmann, R; Lamarche, F; Lauber, J; Layter, J G; Leblanc, P; Lee, A M; Lefebvre, E; Lehto, M H; Lellouch, Daniel; Leroy, C; Letts, J; Levinson, L; Lloyd, S L; Loebinger, F K; Lorah, J M; Lorazo, B; Losty, Michael J; Lou, X C; Ludwig, J; Luig, A; Mannelli, M; Marcellini, S; Markus, C; Martin, A J; Martin, J P; Mashimo, T; Mättig, P; Maur, U; McKenna, J A; McMahon, T J; McNutt, J R; Meijers, F; Menszner, D; Merritt, F S; Mes, H; Michelini, Aldo; Middleton, R P; Mikenberg, G; Mildenberger, J L; Miller, D J; Mir, R; Mohr, W; Moisan, C; Montanari, A; Mori, T; Morii, M; Müller, U; Nellen, B; Nguyen, H H; O'Neale, S W; Oakham, F G; Odorici, F; Ögren, H O; Oram, C J; Oreglia, M J; Orito, S; Pansart, J P; Panzer-Steindel, B; Paschievici, P; Patrick, G N; Paz-Jaoshvili, N; Pearce, M J; Pfister, P; Pilcher, J E; Pinfold, James L; Pitman, D; Plane, D E; Poffenberger, P R; Poli, B; Pritchard, T W; Przysiezniak, H; Quast, G; Redmond, M W; Rees, D L; Richards, G E; Rison, M; Robins, S A; Robinson, D; Rollnik, A; Roney, J M; Ros, E; Rossberg, S; Rossi, A M; Rosvick, M; Routenburg, P; Runge, K; Runólfsson, O; Rust, D R; Sasaki, M; Sbarra, C; Schaile, A D; Schaile, O; Schappert, W; Scharf, F; Scharff-Hansen, P; Schenk, P; Schmitt, B; von der Schmitt, H; Schröder, M; Schwick, C; Schwiening, J; Scott, W G; Settles, M; Shears, T G; Shen, B C; Shepherd-Themistocleous, C H; Sherwood, P; Siroli, G P; Skillman, A; Skuja, A; Smith, A M; Smith, T J; Snow, G A; Sobie, Randall J; Springer, R W; Sproston, M; Stahl, A; Stegmann, C; Stephens, K; Steuerer, J; Ströhmer, R; Strom, D; Takeda, H; Takeshita, T; Tarem, S; Tecchio, M; Teixeira-Dias, P; Tesch, N; Thomson, M A; Torrente-Lujan, E; Towers, S; Tranströmer, G; Tresilian, N J; Tsukamoto, T; Turner, M F; Van den Plas, D; Van Kooten, R; VanDalen, G J; Vasseur, G; Wagner, A; Wagner, D L; Wahl, C; Ward, C P; Ward, D R; Watkins, P M; Watson, A T; Watson, N K; Weber, M; Weber, P; Wells, P S; Wermes, N; Whalley, M A; Wilkens, B; Wilson, G W; Wilson, J A; Winterer, V H; Wlodek, T; Wolf, G; Wotton, S A; Wyatt, T R; Yaari, R; Yeaman, A; Yekutieli, G; Yurko, M; Zeuner, W; Zorn, G T

    1993-01-01

    A Measurement of the Forward-Backward Asymmetry of $e^{+}e^{-} \\to c\\overline{c}$ and $e^{+}e^{-} \\to b\\overline{b}$ at Centre-of-Mass Energies on and near the $Z^{0}$ Peak using $D^{*\\pm}$ Mesons

  17. Comparison of five portable peak flow meters.

    Science.gov (United States)

    Takara, Glaucia Nency; Ruas, Gualberto; Pessoa, Bruna Varanda; Jamami, Luciana Kawakami; Di Lorenzo, Valéria Amorim Pires; Jamami, Mauricio

    2010-05-01

    To compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone, Assess, Galemed, Personal Best and Vitalograph peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (pmeters were 428 (263-688 L/min), 450 (350-800 L/min), 420 (310-720 L/min), 380 (300-735 L/min), 400 (310-685 L/min) and 415 (335-610 L/min), respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone(R) (pmeters. There was no agreement between the spirometric values and the five PEF meters. The results suggest that the values recorded from Galemed meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  18. Influence of a Cooled Ceiling on Indoor Air Quality in a Displacement Ventilated Room Examined by Means of Computational Fluid Dynamics

    DEFF Research Database (Denmark)

    Brohus, Henrik

    The influence of a cooled ceiling on the air quality in a displacement ventilated room is examined by means of CFD. The objective of the study is to examine how the flow field in a displacement ventilated room is influenced when a cooled ceiling removes a major part of the total heat I9ad, and in...

  19. 13 CFR 107.855 - Interest rate ceiling and limitations on fees charged to Small Businesses (“Cost of Money”).

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Interest rate ceiling and... § 107.855 Interest rate ceiling and limitations on fees charged to Small Businesses (“Cost of Money... weighted average interest rate you pay on your “qualified borrowings”. “Qualified borrowings” means your...

  20. Exergy characteristics of a ceiling-type residential air conditioning system operating under different climatic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Arif [Dept. of Mechanical Engineering, Ceyhan Engineering Faculty, Cukurova University, Adana (Turkmenistan)

    2016-11-15

    In this study an energy and exergy analysis of a Ceiling-type residential air conditioning (CTRAC) system operating under different climatic conditions have been investigated for provinces within the different geographic regions of Turkey. Primarily, the hourly cooling load capacities of a sample building (Q{sub evap}) during the months of April, May, June, July, August and September were determined. The hourly total heat gain of the sample building was determined using the Hourly analysis program (HAP). The Coefficient of performance (COP), exergy efficiency (η) and exergy destruction (Ex{sub dest}) values for the whole system and for each component were obtained. The results showed that lower atmospheric temperature (T{sub atm}) influenced the performance of the system and each of its components.

  1. Sealing, especially of dropped ceiling of cubide where main circulating pump of nuclear reactor is installed

    International Nuclear Information System (INIS)

    Paucek, V.

    1980-01-01

    The sealing of the dropped ceiling of the cubicle for main circulating pump installation consists of a reinforcing ring in the space of the pump installation and the top annulus of biological shielding whose inner diameter is smaller than the outer diameter of the bottom biological shielding annulus mounted onto the pump body. The sealing comprises a vertically slidable support ring provided on its underside with an outer ring insert and an outer splice bar for functional gap formation. Slidably mounted in the gap is a guide annular plate tightly attached by means of an inner splice bar and bolts to the bottom biological shielding annulus. Spacers are provided between the reinforcing ring underside and the support ring top surface. (B.S.)

  2. Breaking the glass ceiling: an interview with Dr. Shirley Graves, a pioneering woman in medicine.

    Science.gov (United States)

    Ahmed, Zulfiqar; Mai, Christine L; Elder, Badrea; Rodriguez, Samuel; Yaster, Myron

    2014-04-01

    Shirley Graves M.D., D.Sc. (honorary) (1936), Professor Emeritus of Anesthesiology and Pediatrics at the University of Florida, was one of the most influential women in medicine in the 1960 and 1970s, a time when the medical profession was overwhelmingly male-dominated. In today's society, it is hard to believe that only 50 years ago, women were scarce in the field of medicine. Yet Dr. Graves was a pioneer in the fields of pediatric anesthesia and pediatric critical care medicine. She identifies her development of the pediatric intensive care unit and her leadership in the Division of Pediatric Anesthesia at the University of Florida as her defining contributions. Through her journal articles, book chapters, national and international lectures, and leadership in the American Society of Anesthesiology and the Florida Society of Anesthesiology, she inspired a generation of men and women physicians to conquer the unthinkable and break through the glass ceiling. © 2014 John Wiley & Sons Ltd.

  3. Do emission ceilings ruin coal-fired power plants?; Emissieplafonds nekken kolencentrales?

    Energy Technology Data Exchange (ETDEWEB)

    Wijmenga, J. [Ministerie van Infrastructuur en Milieu, Den Haag (Netherlands)

    2011-04-15

    The case of the new coal-fired power plants has already racked the brains of many. The advice offered to the court by the attorney-general constitutes the next step in this process. A temporary solution has been found for the coal-fired plants, but one question remains unanswered so far: how should an emission ceiling be used as a test instrument for permits? This article provides a direction in which a solution can be found. [Dutch] De zaak betreffende de nieuwe kolencentrales heeft al tot heel wat hoofdbrekens geleid. Het advies dat de advocaat-generaal heeft uitgebracht aan het hof is een volgende stap in dit proces. Voor de kolencentrales is een tijdelijke oplossing gevonden, maar de vraag is nog niet beantwoord hoe een emissieplafond moet worden gebruikt als toetsinstrument voor vergunningen. In dit artikel wordt aangegeven in welke richting een oplossing kan worden gezocht.

  4. The hidden symbols of the female anatomy in Michelangelo Buonarroti's ceiling in the Sistine Chapel.

    Science.gov (United States)

    de Campos, Deivis; Malysz, Tais; Bonatto-Costa, João Antonio; Jotz, Geraldo Pereira; de Oliveira Junior, Lino Pinto; Wichmann, Jéssica Francine; Goulart, Guilherme Reghelin; Stefani, Marco Antonio; da Rocha, Andrea Oxley

    2016-10-01

    A number of published articles have suggested that each element of Renaissance art contains an inner meaning. Some of these elements include the choice of theme and protagonists, faces selected for the characters, colors used, species of flowers and trees chosen, animals depicted, positions of the elements, posture of the characters and their gestures, juxtapositions in the scenes, and even the very scenario or landscape. All of these elements are thought to have hidden meanings. In this context, this manuscript presents a new hypothesis suggesting that Michelangelo Buonarroti (1475-1564) may have concealed symbols associated with female anatomy in the ceiling of the Sistine Chapel (painted 1508-1512) in Rome. Thus, this paper is useful to better understand the history of anatomy and corroborates recent descriptions that have suggested the possible existence of anatomic figures concealed in many of Michelangelo's works. Clin. Anat. 29:911-916, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Experimental study of discharging PCM ceiling panels through nocturnal radiative cooling

    DEFF Research Database (Denmark)

    Bourdakis, Eleftherios; Péan, Thibault Q.; Gennari, Luca

    PhotoVoltaic/Thermal (PV/T) panels were used for cooling water through the principle of nocturnal radiative cooling. This water was utilised for discharging Phase Change Material (PCM) which was embedded in ceiling panels in a climate chamber. Three different sets of flow rates were examined...... for the solar and the PCM loops, for five days each. The highest examined water flow rate (210 l/h) in the PCM loop provided the best thermal environment in the climate chamber, namely 92% of the occupancy time was within the range of Category III of Standard EN 15251. Although the lowest examined water flow...... rate (96 l/h) in the solar loop provided the highest average cooling power, due to the significant variations in the weather conditions during the three experimental cases, made it impossible to determine to which extent the difference in the cooling power is due to the different water flow rate...

  6. Performance of Chilled Beam with Radial Swirl Jet and Diffuse Ceiling Air Supply in Heating Mode

    DEFF Research Database (Denmark)

    Bertheussen, Bård; Mustakallio, Panu; Melikov, Arsen Krikor

    2013-01-01

    ). The room air temperature was kept at 21 °C. Tracer gas was used to simulate pollution from floor and desk. The experimental conditions comprised: 1) night time without heat sources in the room; the room air conditioning system was used to heat up the room; 2) heat load generated by an occupant (simulated...... by dressed thermal manikin) and a laptop; 3) heating by convectors positioned under the window (convectors used alone and convector used together with CSW supplying isothermal air for ventilation). The heat distribution provided by the systems was not effective compare to the distribution provided......The performance of diffuse ceiling air supply and chilled beam with swirl jet (CSW) in heating mode (winter situation) was studied and compared with regard to the generated indoor environment. An office mock-up with one occupant was simulated in a test room (4.5 x 3.95 x 3.5 m3 (L x W x H...

  7. The White ceiling heuristic and the underestimation of Asian-American income.

    Science.gov (United States)

    Martin, Chris C; Nezlek, John B

    2014-01-01

    The belief that ethnic majorities dominate ethnic minorities informs research on intergroup processes. This belief can lead to the social heuristic that the ethnic majority sets an upper limit that minority groups cannot surpass, but this possibility has not received much attention. In three studies of perceived income, we examined how this heuristic, which we term the White ceiling heuristic leads people to inaccurately estimate the income of a minority group that surpasses the majority. We found that Asian Americans, whose median income has surpassed White median income for nearly three decades, are still perceived as making less than Whites, with the least accurate estimations being made by people who strongly believe that Whites are privileged. In contrast, income estimates for other minorities were fairly accurate. Thus, perceptions of minorities are shaped both by stereotype content and a heuristic.

  8. Hierarchical rank and women's organizational mobility: glass ceilings in corporate law firms.

    Science.gov (United States)

    Gorman, Elizabeth H; Kmec, Julie A

    2009-03-01

    This article revives the debate over whether women's upward mobility prospects decline as they climb organizational hierarchies. Although this proposition is a core element of the "glass ceiling" metaphor, it has failed to gain strong support in previous research. The article establishes a firm theoretical foundation for expecting an increasing female disadvantage, with an eye toward defining the scope conditions and extending the model to upper-level external hires. The approach is illustrated in an empirical setting that meets the proposed scope conditions: corporate law firms in the United States. Results confirm that in this setting, the female mobility disadvantage is greater at higher organizational levels in the case of internal promotions, but not in the case of external hires.

  9. De Soweto à Ceilândia: siglas de segregação racial

    Directory of Open Access Journals (Sweden)

    Guilherme Oliveira Lemos

    2017-08-01

    Full Text Available A proposta desse trabalho é pensar relações comuns ou, pelo menos, aproximadas sobre os processos e os instrumentos de segregação urbana racial, generificada e social nas cidades de Soweto (Joanesburgo - África do Sul e Ceilândia (Distrito Federal - Brasil durante as décadas de 1950 e 1970. Para tanto, comparamos os dois processos de remoção das populações dos centros para as periferias e a (reinvenção dos tipos corpóreos (“candango”, “black”, “african”, “coloured” destinados a ocupar os limites da não-vida, ou seja, as  chamadas cidades satélites. Metodologicamente a pesquisa, de caráter inicial, fez-se através da análise indiciaria e comparativa de documentos oficiais, relatos orais e bibliografias referentes às duas cidades. A aproximação analítica/histórica entre esses casos se tornou possível através do conceito de necropolítica e da correlação entre escravidão, colonialismo e apartheid: três eventos imaginados historiograficamente como distintos, mas onde a dissociação do ser ao direito de sua própria vida rompem as barreiras do tempo e, no caso Soweto-Ceilândia, as fronteiras do Atlântico.

  10. The Time Bounded Glass Ceiling and Young Women Managers: Career Progress and Career Success--Evidence from the UK.

    Science.gov (United States)

    Simpson, Ruth; Altman, Yochanan

    2000-01-01

    A study of 130 male and 91 female managers found that more younger women than men were in senior roles. Younger women achieved seniority faster than women over 35. However, once younger women have broken the glass ceiling at lower levels, they encounter new barriers at higher levels. (SK)

  11. Academe's Glass Ceiling: Societal, Professional-Organizational, and Institutional Barriers to the Career Advancement of Academic Women.

    Science.gov (United States)

    Bain, Olga; Cummings, William

    2000-01-01

    A survey of 10 national systems of higher education found that less than 10 percent of professors were women, and the proportion of female professors was negatively related to institutional prestige. This academic "glass ceiling" was related to women's shorter careers, tenure issues during hard times, and women's lower level of academic…

  12. Review Symposium; Dancing on the Ceiling: A Study of Women Managers in Education, by Valerie Hall. London: Paul Chapman, 1996.

    Science.gov (United States)

    Hall, Valerie; Gronn, Peter; Jenkin, Mazda; Power, Sally; Reynolds, Cecilia

    1999-01-01

    Hall and four colleagues review "Dancing on the Ceiling: A Study of Women Managers in Education" (Paul Chapman, 1996). Reviewers agree that Hall's profiles of six British elementary and secondary women headteachers should improve readers' understanding of female managers' development and their preference for "soft,"…

  13. Experimental study of diffuse ceiling ventilation coupled with a thermally activated building construction in an office room

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Pomianowski, Michal Zbigniew

    2015-01-01

    the opposite effect on energy performance when TABS is activated in heating or cooling mode. Finally, the air temperature distribution in the plenum and the surface temperature distribution of the diffuse ceiling point out that the air does not perfectly mix in the plenum, the air is not evenly distributed...

  14. Ceiling erosion in caves: early studies and Zdeněk Roth as author of the concept

    Czech Academy of Sciences Publication Activity Database

    Bella, P.; Bosák, Pavel

    2015-01-01

    Roč. 44, č. 1 (2015), s. 139-144 ISSN 0583-6050 Institutional support: RVO:67985831 Keywords : ceiling channel * paragenesis * antigravitative erosion * definition * Zdeněk Roth * Domica Cave * Slovak Karst Subject RIV: DB - Geology ; Mineralogy Impact factor: 0.792, year: 2015

  15. Application of a permanent magnet biased E-Core reluctance actuator in a magnetically suspended ceiling actuator

    NARCIS (Netherlands)

    Overboom, T.T.; Jansen, J.W.; Lomonova, E.

    2010-01-01

    In the paper a novel actuator is presented for a magnetically suspended ceiling actuator. The actuator consists of several stator segments which contain the coils and the magnets. The armature, therefore, has a totally passive design. Because of its salient structure, a translational force can be

  16. Does the Glass Ceiling Exist? A Longitudinal Study of Women’s Progress on French Corporate Boards

    OpenAIRE

    Rey Dang; Duc Khuong Nguyen; Linh-Chi Vo

    2014-01-01

    In this article, we conduct a longitudinal study of women’s progress on French corporate boards of directors. We particularly focus on the extent to which women directors have circumvented the glass ceiling. Using a sample of SBF 120 companies over a 10

  17. Experimental investigation of cooling performance of a novel HVAC system combining natural ventilation with diffuse ceiling inlet and TABS

    DEFF Research Database (Denmark)

    Yu, Tao; Heiselberg, Per Kvols; Lei, Bo

    2015-01-01

    Highlights •An experimental investigation of cooling performance of a combined HVAC system is carried out. •Cooling performance of TABS with and without the influence of diffuse ceiling is analyzed. •Radiant and convective heat transfer coefficients of TABS cooling are studied. •Cooling components...

  18. Numerical investigation of upper-room UVGI disinfection efficacy in an environmental chamber with a ceiling fan.

    Science.gov (United States)

    Zhu, Shengwei; Srebric, Jelena; Rudnick, Stephen N; Vincent, Richard L; Nardell, Edward A

    2013-01-01

    This study investigated the disinfection efficacy of the upper-room ultraviolet germicidal irradiation (UR-UVGI) system with ceiling fans. The investigation used the steady-state computational fluid dynamics (CFD) simulations to solve the rotation of ceiling fan with a rotating reference frame. Two ambient air exchange rates, 2 and 6 air changes per hour (ACH), and four downward fan rotational speeds, 0, 80, 150 and 235 rpm were considered. In addition, the passive scalar concentration simulations incorporated ultraviolet (UV) dose by two methods: one based on the total exposure time and average UV fluence rate, and another based on SVE3* (New Scale for Ventilation Efficiency 3), originally defined to evaluate the mean age of the air from an air supply opening. Overall, the CFD results enabled the evaluation of UR-UVGI disinfection efficacy using different indices, including the fraction of remaining microorganisms, equivalent air exchange rate, UR-UVGI effectiveness and tuberculosis infection probability by the Wells-Riley equation. The results indicated that air exchange rate was the decisive factor for determining UR-UVGI performance in disinfecting indoor air. Using a ceiling fan could also improve the performance in general. Furthermore, the results clarified the mechanism for the ceiling fan to influence UR-UVGI disinfection efficacy. © 2013 The Authors Photochemistry and Photobiology © 2013 The American Society of Photobiology.

  19. Structural analysis of a rehabilitative training system based on a ceiling rail for safety of hemiplegia patients.

    Science.gov (United States)

    Kim, Kyong; Song, Won Kyung; Chong, Woo Suk; Yu, Chang Ho

    2018-04-17

    The body-weight support (BWS) function, which helps to decrease load stresses on a user, is an effective tool for gait and balance rehabilitation training for elderly people with weakened lower-extremity muscular strength, hemiplegic patients, etc. This study conducts structural analysis to secure user safety in order to develop a rail-type gait and balance rehabilitation training system (RRTS). The RRTS comprises a rail, trolley, and brain-machine interface. The rail (platform) is connected to the ceiling structure, bearing the loads of the RRTS and of the user and allowing locomobility. The trolley consists of a smart drive unit (SDU) that assists the user with forward and backward mobility and a body-weight support (BWS) unit that helps the user to control his/her body-weight load, depending on the severity of his/her hemiplegia. The brain-machine interface estimates and measures on a real-time basis the body-weight (load) of the user and the intended direction of his/her movement. Considering the weight of the system and the user, the mechanical safety performance of the system frame under an applied 250-kg static load is verified through structural analysis using ABAQUS (6.14-3) software. The maximum stresses applied on the rail and trolley under the given gravity load of 250 kg, respectively, are 18.52 MPa and 48.44 MPa. The respective safety factors are computed to be 7.83 and 5.26, confirming the RRTS's mechanical safety. An RRTS with verified structural safety could be utilized for gait movement and balance rehabilitation and training for patients with hemiplegia.

  20. Climatic and technological ceilings for Chinese rice stagnation based on yield gaps and yield trend pattern analysis.

    Science.gov (United States)

    Zhang, Tianyi; Yang, Xiaoguang; Wang, Hesong; Li, Yong; Ye, Qing

    2014-04-01

    Climatic or technological ceilings could cause yield stagnation. Thus, identifying the principal reasons for yield stagnation within the context of the local climate and socio-economic conditions are essential for informing regional agricultural policies. In this study, we identified the climatic and technological ceilings for seven rice-production regions in China based on yield gaps and on a yield trend pattern analysis for the period 1980-2010. The results indicate that 54.9% of the counties sampled experienced yield stagnation since the 1980. The potential yield ceilings in northern and eastern China decreased to a greater extent than in other regions due to the accompanying climate effects of increases in temperature and decreases in radiation. This may be associated with yield stagnation and halt occurring in approximately 49.8-57.0% of the sampled counties in these areas. South-western China exhibited a promising scope for yield improvement, showing the greatest yield gap (30.6%), whereas the yields were stagnant in 58.4% of the sampled counties. This finding suggests that efforts to overcome the technological ceiling must be given priority so that the available exploitable yield gap can be achieved. North-eastern China, however, represents a noteworthy exception. In the north-central area of this region, climate change has increased the yield potential ceiling, and this increase has been accompanied by the most rapid increase in actual yield: 1.02 ton ha(-1) per decade. Therefore, north-eastern China shows a great potential for rice production, which is favoured by the current climate conditions and available technology level. Additional environmentally friendly economic incentives might be considered in this region. © 2013 John Wiley & Sons Ltd.

  1. Effects of Glass Ceiling on Women Career Development in Private Sector Organizations – Case of Sri Lanka

    Directory of Open Access Journals (Sweden)

    Bombuwela P. M.

    2013-06-01

    Full Text Available The study was entirely designed by centering the focal problem of the effect of Glass Ceiling on Women Career Development. The overall study was structure based on the conceptual framework built up using the information of literature survey. The study was conducted with the aim of obtaining the following objective. That is “To find out the Effect of Glass Ceiling on Women Career Development with regard to female executive level employees who are working in privatesector organizations.” At the same time, hypotheses are developed to find out whether there is a significant effect of Individual Factors, Family Factors, Organizational Factors and Cultural Factors on Women Career development. Merely this study has been completed with an empirical survey which was thoroughly conducted using a self-administered questionnaire and the sample consisted of 150 women executives. For presenting and analyzing the data both descriptive andinferential statistics were used. The findings reveal that the Glass Ceiling and Women Career Development have a moderate negative relationship, and also show that Individual Factors, OrganizationalFactors and Cultural Factors have a significant effect on Women Career Development whereas Family Factor has effects on the Glass Ceiling. Following the study results, a conclusion was eventually made that there are significant effects of the Glass Ceiling on WomenCareer Development of Executive level female employees working in private sector organizations in Sri Lanka. By taking all these facts into consideration, better recommendations have been made in this study. Finally, the most valuable suggestions for further studies and limitations of the study have been outlined.

  2. Relaxation peak near 200 K in NiTi alloy

    Science.gov (United States)

    Zhu, J. S.; Schaller, R.; Benoit, W.

    1989-10-01

    Internal friction (IF), frequency ( f), electrical resistance ( R) and zero point movement of the torsion pendulum (ɛ) have been measured in near equi-atomic NiTi alloy in order to clarify the mechanism for the relaxation peak near 200 K. The height of the relaxation peak decreases successively with thermal cycling and settles down to a lower stable value in running 15 cycles. However, the electrical resistance of the sample shows a variation in contrast with the internal friction. Both of them will return to the initial state after a single annealing at 773 K for 1 h. The probable mechanism of this relaxation peak was discussed.

  3. Neutron-induced peaks in Ge detectors from evaporation neutrons

    International Nuclear Information System (INIS)

    Gete, E.; Measday, D.F.; Moftah, B.A.; Saliba, M.A.; Stocki, T.J.

    1997-01-01

    We have studied the peak shapes at 596 and 691 keV resulting from fast neutron interactions inside germanium detectors. We have used neutrons from a 252 Cf source, as well as from the 28 Si(μ - , nν), and 209 Bi(π - , xn) reactions to compare the peaks and to check for a dependence of peak shape on the incoming neutron energy. In our investigation, no difference between these three measurements has been observed. In a comparison of these peak shapes with other studies, we found similar results to ours except for those measurements using monoenergetic neutrons in which a significant variation with neutron energy has been observed. (orig.)

  4. Evaluation of different time domain peak models using extreme learning machine-based peak detection for EEG signal.

    Science.gov (United States)

    Adam, Asrul; Ibrahim, Zuwairie; Mokhtar, Norrima; Shapiai, Mohd Ibrahim; Cumming, Paul; Mubin, Marizan

    2016-01-01

    Various peak models have been introduced to detect and analyze peaks in the time domain analysis of electroencephalogram (EEG) signals. In general, peak model in the time domain analysis consists of a set of signal parameters, such as amplitude, width, and slope. Models including those proposed by Dumpala, Acir, Liu, and Dingle are routinely used to detect peaks in EEG signals acquired in clinical studies of epilepsy or eye blink. The optimal peak model is the most reliable peak detection performance in a particular application. A fair measure of performance of different models requires a common and unbiased platform. In this study, we evaluate the performance of the four different peak models using the extreme learning machine (ELM)-based peak detection algorithm. We found that the Dingle model gave the best performance, with 72 % accuracy in the analysis of real EEG data. Statistical analysis conferred that the Dingle model afforded significantly better mean testing accuracy than did the Acir and Liu models, which were in the range 37-52 %. Meanwhile, the Dingle model has no significant difference compared to Dumpala model.

  5. Development of the modified sum-peak method and its application

    International Nuclear Information System (INIS)

    Ogata, Y.; Miyahara, H.; Ishihara, M.; Ishigure, N.; Yamamoto, S.; Kojima, S.

    2016-01-01

    As the sum-peak method requires the total count rate as well as the peak count rates and the sum peak count rate, this meets difficulties when a sample contains other radionuclides than the one to be measured. To solve the problem, a new method using solely the peak and the sum peak count rates was developed. The method was theoretically and experimentally confirmed using "6"0Co, "2"2Na and "1"3"4Cs. We demonstrate that the modified sum-peak method is quite simple and practical and is useful to measure multiple nuclides. - Highlights: • A modified sum-peak method for simple radioactivity measurement was developed. • The method solely requires the peak count rates and the sum peak count rate. • The method is applicable to multiple radionuclides.

  6. Comparison of five portable peak flow meters

    Directory of Open Access Journals (Sweden)

    Glaucia Nency Takara

    2010-01-01

    Full Text Available OBJECTIVE: To compare the measurements of spirometric peak expiratory flow (PEF from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. METHODS: Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (p<0.05, Spearman's correlation test and Bland-Altman's agreement test. RESULTS: The median and interquartile ranges for the spirometric values and the Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® meters were 428 (263-688 L/min, 450 (350-800 L/min, 420 (310-720 L/min, 380 (300-735 L/min, 400 (310-685 L/min and 415 (335-610 L/min, respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone® (p<0.001 and Galemed ® (p<0.01 meters. There was no agreement between the spirometric values and the five PEF meters. CONCLUSIONS: The results suggest that the values recorded from Galemed® meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone® meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  7. Concentrations and loads of cadmium, lead, and zinc measured near the peak of the 1999 snowmelt-runoff hydrographs for 42 water-quality stations, Coeur d'Alene River basin, Idaho

    Science.gov (United States)

    Woods, Paul F.

    2000-01-01

    The Remedial Investigation/Feasibility Study conducted by the U.S. Environmental Protection Agency within the Spokane River Basin of northern Idaho and eastern Washington included extensive data-collection activities to determine the nature and extent of trace-element contamination within the basin. The U.S. Geological Survey designed and implemented synoptic sampling of the 1999 snowmelt-runoff event at 42 water- quality stations during the 1999 water year. The distribution of the 42 stations was as follows: North Fork Coeur d’Alene River and tributaries, 4 stations; South Fork Coeur d’Alene River, 13 stations; Canyon, Ninemile, and Pine Creeks, 4 stations each; other tributaries to South Fork Coeur d’Alene River, 10 stations; and main stem Coeur d’Alene River, 3 stations. The objective was to synoptically collect discharge and water-quality data in order to significantly improve the estimation of trace-element loads from multiple contributing source areas during the snowmelt-runoff event. Discharge and water-quality data were collected near the peak discharge during late May 1999. Each station was sampled for whole-water recoverable and dissolved concentrations and loads of cadmium, lead, and zinc.

  8. Prediction of iodine activity peak during refuelling

    International Nuclear Information System (INIS)

    Hozer, Z.; Vajda, N.

    2001-01-01

    The increase of fission product activities in the primary circuit of a nuclear power plant indicates the existence of defects in some fuel rods. The power change leads to the cooling down of the fuel and results in the fragmentation of the UO 2 pellets, which facilitates the release of fission products from the intergranular regions. Furthermore the injection of boric acid after shutdown will increase the primary activity, due to the solution of deposited fission products from the surface of the core components. The calculation of these phenomena usually is based on the evaluation of activity measurements and power plant data. The estimation of iodine spiking peak during reactor transients is based on correlation with operating parameters, such as reactor power and primary pressure. The approach used in the present method was applied for CANDU reactors. The VVER-440 specific correlations were determined using the activity measurements of the Paks NPP and the data provided by the Russian fuel supplier. The present method is used for the evaluation of the iodine isotopes, as well as the noble gases. A numerical model has been developed for iodine spiking simulation and has been validated against several shutdown transients, measured at Paks NPP. (R.P.)

  9. Peak globalization. Climate change, oil depletion and global trade

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, Fred [Department of Economics, Drew University, Madison, NJ 07940 (United States)

    2009-12-15

    The global trade in goods depends upon reliable, inexpensive transportation of freight along complex and long-distance supply chains. Global warming and peak oil undermine globalization by their effects on both transportation costs and the reliable movement of freight. Countering the current geographic pattern of comparative advantage with higher transportation costs, climate change and peak oil will thus result in peak globalization, after which the volume of exports will decline as measured by ton-miles of freight. Policies designed to mitigate climate change and peak oil are very unlikely to change this result due to their late implementation, contradictory effects and insufficient magnitude. The implication is that supply chains will become shorter for most products and that production of goods will be located closer to where they are consumed. (author)

  10. Peak globalization. Climate change, oil depletion and global trade

    International Nuclear Information System (INIS)

    Curtis, Fred

    2009-01-01

    The global trade in goods depends upon reliable, inexpensive transportation of freight along complex and long-distance supply chains. Global warming and peak oil undermine globalization by their effects on both transportation costs and the reliable movement of freight. Countering the current geographic pattern of comparative advantage with higher transportation costs, climate change and peak oil will thus result in peak globalization, after which the volume of exports will decline as measured by ton-miles of freight. Policies designed to mitigate climate change and peak oil are very unlikely to change this result due to their late implementation, contradictory effects and insufficient magnitude. The implication is that supply chains will become shorter for most products and that production of goods will be located closer to where they are consumed. (author)

  11. Passive radio frequency peak power multiplier

    Science.gov (United States)

    Farkas, Zoltan D.; Wilson, Perry B.

    1977-01-01

    Peak power multiplication of a radio frequency source by simultaneous charging of two high-Q resonant microwave cavities by applying the source output through a directional coupler to the cavities and then reversing the phase of the source power to the coupler, thereby permitting the power in the cavities to simultaneously discharge through the coupler to the load in combination with power from the source to apply a peak power to the load that is a multiplication of the source peak power.

  12. Practical load management - Peak shaving using photovoltaics

    International Nuclear Information System (INIS)

    Berger, W.

    2009-01-01

    This article takes a look at how photovoltaic (PV) power generation can be used in a practical way to meet peak demands for electricity. Advice is provided on how photovoltaics can provide peak load 'shaving' through the correlation between its production and the peak loads encountered during the day. The situation regarding feed-in tariffs in Italy is discussed, as are further examples of installations in Germany and Austria. Further, an initiative of the American Southern California Edison utility is discussed which foresees the installation of large PV plant on the roofs of commercial premises to provide local generation of peak energy and thus relieve demands on their power transportation network.

  13. The geomorphic structure of the runoff peak

    Directory of Open Access Journals (Sweden)

    R. Rigon

    2011-06-01

    Full Text Available This paper develops a theoretical framework to investigate the core dependence of peak flows on the geomorphic properties of river basins. Based on the theory of transport by travel times, and simple hydrodynamic characterization of floods, this new framework invokes the linearity and invariance of the hydrologic response to provide analytical and semi-analytical expressions for peak flow, time to peak, and area contributing to the peak runoff. These results are obtained for the case of constant-intensity hyetograph using the Intensity-Duration-Frequency (IDF curves to estimate extreme flow values as a function of the rainfall return period. Results show that, with constant-intensity hyetographs, the time-to-peak is greater than rainfall duration and usually shorter than the basin concentration time. Moreover, the critical storm duration is shown to be independent of rainfall return period as well as the area contributing to the flow peak. The same results are found when the effects of hydrodynamic dispersion are accounted for. Further, it is shown that, when the effects of hydrodynamic dispersion are negligible, the basin area contributing to the peak discharge does not depend on the channel velocity, but is a geomorphic propriety of the basin. As an example this framework is applied to three watersheds. In particular, the runoff peak, the critical rainfall durations and the time to peak are calculated for all links within a network to assess how they increase with basin area.

  14. [A peak recognition algorithm designed for chromatographic peaks of transformer oil].

    Science.gov (United States)

    Ou, Linjun; Cao, Jian

    2014-09-01

    In the field of the chromatographic peak identification of the transformer oil, the traditional first-order derivative requires slope threshold to achieve peak identification. In terms of its shortcomings of low automation and easy distortion, the first-order derivative method was improved by applying the moving average iterative method and the normalized analysis techniques to identify the peaks. Accurate identification of the chromatographic peaks was realized through using multiple iterations of the moving average of signal curves and square wave curves to determine the optimal value of the normalized peak identification parameters, combined with the absolute peak retention times and peak window. The experimental results show that this algorithm can accurately identify the peaks and is not sensitive to the noise, the chromatographic peak width or the peak shape changes. It has strong adaptability to meet the on-site requirements of online monitoring devices of dissolved gases in transformer oil.

  15. Thou shalt not pass?: Examining the existence of an immigrant glass ceiling in Sweden, 1970-1990

    Directory of Open Access Journals (Sweden)

    Jonas Helgertz

    2011-01-01

    Full Text Available The paper studies a sample of natives and 18 immigrant nationalities in the Swedish labor market between 1970 and 1990. The purpose is examining the existence of an immigrant specific glass ceiling. Results suggest a considerable overall advantage in terms of the probability of experiencing upward occupational mobility for native Swedish males. Despite this, the pattern does not correspond to the theoretical expectations of a glass ceiling. Using the ISEI classification of occupational status, the advantage experienced by Swedish males is consistent in the private manufacturing and private service sectors, compared to the experience of immigrants and women. The public sector generally suggests a similar pattern according to linguistic background. In this sector, certain groups of women are, however, observed to experience an advantage from low occupational status origins.

  16. Radiant Ceiling Panels Combined with Localized Methods for Improved Thermal Comfort of Both Patient and Medical Staff in Patient Room

    DEFF Research Database (Denmark)

    Mori, Sakura; Barova, Mariya; Bolashikov, Zhecho Dimitrov

    2012-01-01

    The objectives were to identify whether ceiling installed radiant heating panels can provide thermal comfort to the occupants in a patient room, and to determine a method for optimal thermal environment to both patient and medical staff simultaneously. The experiments were performed in a climate...... mattress were used to provide local heating for the patient. The effects of the methods were identified by comparing the manikin based equivalent temperatures. The optimal thermal comfort level for both patient and medical staff would obtained when two conventional cotton blankets were used with extra...... chamber resembling a single-bed patient room under convective air conditioning alone or combined with the ceiling installed radiant heating panels. Two thermal manikins simulated a patient lying in the bed and a doctor standing next to the patient. Conventional cotton blanket, electric blanket, electric...

  17. A Simulation Study on the Performance of Radiant Ceilings Combined with Free-Hanging Horizontal Sound Absorbers

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Domínguez, L. Marcos; Rage, Niels

    2018-01-01

    using TABS, most building simulation models assume an uncovered ceiling; however, this might not be the case in practice, due to the use of free-hanging horizontal (or vertical) sound absorbers for the control of room acoustic conditions. The use of sound absorbers will decrease the performance...... of radiant ceiling cooling systems. Therefore, the quantification of the effects during the design phase is important for predicting the resulting thermal indoor environment and for system dimensioning. In this study, a two-person office room equipped with TABS was simulated using a commercially available...... simulation software with a recently developed plug-in that allows simulating the effects of horizontal sound absorbers on the performance of TABS and on the thermal indoor environment. The change in thermal indoor environment and in performance of TABS were quantified, and the simulation results were...

  18. Privacy-Preserved Behavior Analysis and Fall Detection by an Infrared Ceiling Sensor Network

    Directory of Open Access Journals (Sweden)

    Mineichi Kudo

    2012-12-01

    Full Text Available An infrared ceiling sensor network system is reported in this study to realize behavior analysis and fall detection of a single person in the home environment. The sensors output multiple binary sequences from which we know the existence/non-existence of persons under the sensors. The short duration averages of the binary responses are shown to be able to be regarded as pixel values of a top-view camera, but more advantageous in the sense of preserving privacy. Using the “pixel values” as features, support vector machine classifiers succeeded in recognizing eight activities (walking, reading, etc. performed by five subjects at an average recognition rate of 80.65%. In addition, we proposed a martingale framework for detecting falls in this system. The experimental results showed that we attained the best performance of 95.14% (F1 value, the FAR of 7.5% and the FRR of 2.0%. This accuracy is not sufficient in general but surprisingly high with such low-level information. In summary, it is shown that this system has the potential to be used in the home environment to provide personalized services and to detect abnormalities of elders who live alone.

  19. Kinetic and equilibrium studies of cesium adsorption on ceiling tiles from aqueous solutions.

    Science.gov (United States)

    Miah, Muhammed Yusuf; Volchek, Konstantin; Kuang, Wenxing; Tezel, F Handan

    2010-11-15

    A series of experiments were performed to quantify the adsorption of cesium on ceiling tiles as a representative of urban construction materials. Adsorption was carried out from solutions to mimic wet environmental conditions. Non-radioactive cesium chloride was used as a surrogate of the radioactive (137)Cs. The experiments were performed in the range of initial cesium concentrations of 0.114-23.9 mg L(-1) at room temperature (21°C) around three weeks. Solution samples were taken after set periods of time and analyzed by inductively coupled plasma mass spectrometry (ICP-MS). The quantity of adsorbed Cs was calculated by mass balance as a function of time. Two kinetic and three equilibrium models were employed to interpret the test results. Determination of kinetic parameters for adsorption was carried out using the first-order reaction model and the intra-particle diffusion model. Adsorption equilibrium was studied using Langmuir, Freundlich and three-parameter Langmuir-Freundlich adsorption isotherm models. A satisfactory correlation between the experimental and the predicted values was observed. Crown Copyright © 2010. Published by Elsevier B.V. All rights reserved.

  20. Kinetic and equilibrium studies of cesium adsorption on ceiling tiles from aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Miah, Muhammed Yusuf [Emergencies Science and Technology Section, Environment Canada, 335 River Road, Ottawa, Ontario, K1A 0H3 (Canada); Department of Applied Chemistry and Chemical Technology, Noakhali Science and Technology University (Bangladesh); Volchek, Konstantin, E-mail: Konstantin.Volchek@ec.gc.ca [Emergencies Science and Technology Section, Environment Canada, 335 River Road, Ottawa, Ontario, K1A 0H3 (Canada); Kuang, Wenxing [SAIC Canada, 335 River Road, Ottawa, Ontario, K1A 0H3 (Canada); Tezel, F. Handan [Department of Chemical and Biological Engineering, University of Ottawa, 161 Louis-Pasteur, Ottawa, Ontario, K1N 6N5 (Canada)

    2010-11-15

    A series of experiments were performed to quantify the adsorption of cesium on ceiling tiles as a representative of urban construction materials. Adsorption was carried out from solutions to mimic wet environmental conditions. Non-radioactive cesium chloride was used as a surrogate of the radioactive {sup 137}Cs. The experiments were performed in the range of initial cesium concentrations of 0.114-23.9 mg L{sup -1} at room temperature (21 deg. C) around three weeks. Solution samples were taken after set periods of time and analyzed by inductively coupled plasma mass spectrometry (ICP-MS). The quantity of adsorbed Cs was calculated by mass balance as a function of time. Two kinetic and three equilibrium models were employed to interpret the test results. Determination of kinetic parameters for adsorption was carried out using the first-order reaction model and the intra-particle diffusion model. Adsorption equilibrium was studied using Langmuir, Freundlich and three-parameter Langmuir-Freundlich adsorption isotherm models. A satisfactory correlation between the experimental and the predicted values was observed.

  1. Protection of High Ceiling Nuclear Facilities Using Photoelectric Sensors and Infrared Fire Detectors

    International Nuclear Information System (INIS)

    Wadoud, A.A.; El Eissawi, H.M.; Saleh, A.A.

    2017-01-01

    A variety of different security systems and components are commercially available and widely used. Before implementing a security system, it is important to understand the characteristics and requirements of the facility area to be protected. Technology and manufacturers of security devices are rapidly changing. It is necessary to use optimal security equipment suitable for the surrounding environment of the facility to be protected. Several security sensors can be used to protect the nuclear facilities, such as passive infrared detectors and glass breakage sensors, vibration detectors, and microwave sensors. This work introduces technical specifications, operation and method of installation for these detectors in nuclear facilities. Also a comparative study of different security sensors or equipment is provided. The photoelectric detectors and infrared fire beam smoke detectors are reliable, suitable and advanced security equipment. They can be used in special cases because of their advantages, this includes their long ranges and accuracy in performance. This paper presents a new concept for adapting the use infrared optical fire beam smoke detector as intrusion detection equipment in high ceiling buildings or towering height facilities. This is in addition to their main function, namely fire detection.The paper also provides a study for their types and installation method. Focus is made on the installation and operation method for two advanced security systems, and wireless control circuit for the overall system operation

  2. Pride and prejudice beyond the glass ceiling: Brazilian female executives´ psychological type

    Directory of Open Access Journals (Sweden)

    Betania Tanure

    2014-08-01

    Full Text Available http://dx.doi.org/10.5007/2175-8077.2014v16n39p210 This paper intends to relate characteristics of female executive psychological type with their male colleagues in corporations operating in Brazil (CEOs, VPs/directors and top managers. The theoretical framework explores the glass ceiling and the prejudices faced by female executives. It was developed a mixed qualitative-quantitative method. In the quantitative part we interviewed 743 men and 222 women from 344 corporations. We applied also the questionnaire MBTI to 430 of these executives. In the qualitative part we held focus groups with 227 individuals and 104 semi-structured interviews. The most active psychological MBTI type found was the ESTJ, both to men and women. The dominant characteristics in this type is more rational, logical and less emotional. Prejudices are huge: women need to work harder to show that they are as competent as men. They also live the society's pressure in relation to the roles as mother and wife.

  3. Breaking through the glass ceiling: women in executive leadership positions--Part I.

    Science.gov (United States)

    Parsons, Lynn C; Reiss, Patricia L

    2004-01-01

    Women have had their share of difficulties climbing the corporate ladder in their chosen professional roles. Excellent role models exist for nurses to look up to as role models for leadership and executive level positions. Nurses and women must strive to achieve their goals of attaining executive/management level positions in their respective organizations. The glass ceiling still exists; however, women are slowly eroding that glass barrier and reaching their professional goals. In reviewing the struggles that men in nursing have encountered in a predominantly female profession, one realizes that stereotypical attitudes do cross gender lines. The authors conclude that executive level positions need to be opened more to women, just as the nursing profession must be more welcoming to men. The profession of nursing will only become stronger with gender diversity. Women encounter barriers when aspiring to executive level positions. In the next issue of SCI Nursing, the authors will report on what the evidence says about women in leadership roles, and the challenges they have and will continue to face.

  4. Does debt ceiling and government shutdown help in forecasting the us equity risk premium?

    Directory of Open Access Journals (Sweden)

    Aye Goodness C.

    2016-01-01

    Full Text Available This article evaluates the predictability of the equity risk premium in the United States by comparing the individual and complementary predictive power of macroeconomic variables and technical indicators using a comprehensive set of 16 economic and 14 technical predictors over a monthly out-ofsample period of 1995:01 to 2012:12 and an in-sample period of 1986:01- 1994:12. In order to do so we consider, in addition to the set of variables used in Christopher J. Neely et al. (2013 and using a more recent dataset, the forecasting ability of two other important variables namely government shutdown and debt ceiling. Our results show that one of the newly added variables namely government shutdown provides statistically significant out-of-sample predictive power over the equity risk premium relative to the historical average. Most of the variables, including government shutdown, also show significant economic gains for a risk averse investor especially during recessions.

  5. Heavy Metal Concentrations in Ceiling Fan Dusts Sampled at Schools Around Serdang Area, Selangor

    International Nuclear Information System (INIS)

    Yap, C.K.; Krishnan, T.; Chew, W.

    2011-01-01

    In this study, ceiling fan dust samples were collected from three schools in the district of Serdang Selangor, Malaysia. The sampled dust were analysed for the concentrations of Cd, Cu, Fe, Ni, Pb and Zn. The heavy metal ranges found in all the schools were 2.96-7.74 μg/ g dry weight for Cd, 75-442 μg/ g dry weight for Cu, 3445-3852 μg/ g dry weight for Fe, 24-66 μg/ g dry weight for Ni, 140-734 μg/ g dry weight for Pb and 439-880 μg/ g dry weight for Zn. SMK Seri Serdang School was found to have elevated concentrations of Cd, Cu, Ni, Pb, and Zn which indicated the anthropogenic sources of the study sites. In comparison to other reported studies in the literature, the maximum levels of Cd, Cu, Ni, and Pb were comparable or higher to those cities reported. Therefore, more monitoring studies should be conducted in future since dusts could be related to human health hazards and the dusts can be used as a potential monitoring tool for heavy metal pollution in the atmosphere. (author)

  6. GIS approach to the definition of capacity and generation ceilings of renewable energy technologies

    International Nuclear Information System (INIS)

    Dominguez Bravo, Javier; Garcia Casals, Xavier; Pinedo Pascua, Irene

    2007-01-01

    There are no discrepancies about the advantages of achieving a sustainable energy system based on locally available natural resources. However, supporters of green energy generation system were lacking some scientific and consistent study to defend their proposals. In order to have such a study, Greenpeace commissioned Technology Research Institute at the Pontificia Comillas University to carry out a study to assess ceilings for the potential and generation of renewable technologies in Spain. It demonstrates firstly a far greater renewable potential than the targets set by long term policies, and secondly, the viability of meeting the entire electricity demand projected for 2050. GIS was used to add the geographical dimension to the original project in order to generate a technical analysis linked to the specific constrictions imposed by territory (natural and anthropogenic) and not just designed to cover a certain demand. Therefore, GIS spatial analysis took into account local conditions producing a more accurate assessment than evaluations made upon 'virtual' electrical spaces. This approach could be applied to other small scale general studies in order to assess the maximum contribution of renewable energy sources to particular energy generation mix and to help set development policies supporting high participation of renewable technologies

  7. Fresh-air cooling ceilings in an administration building; Frischluft-Kuehldecken in einem Verwaltungsgebaeude

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, W

    1995-06-01

    In the construction of the new building of the Deutsche Innenbau GmbH in Muelheim much importance was attached to aesthetics and functionality. If the employees are enthusiastic after one year of operation this is mainly due to the ideal climatic conditions: Glazings with insulating glass (k=1,4 W/m{sup 2}k), high-quality thermal insulation of the breasts shading system with motor-driven screen at the outside, radiators with thermostatic valves and a fresh air cooling ceiling. The article describes the course of construction of the total air-conditioning and ventilation technique. (orig.) [Deutsch] Beim Neubau der DIG Deutsche Innenbau GmbH in Muelheim an der Ruhr legte man grossen Wert auf Aesthetik und Funktionalitaet. Wenn die Mitarbeiter nach einem Jahr Betrieb begeistert sind, so liegt dies grossenteils an idealen klimatechnischen Voraussetzungen: Verglasung mit Waermeschutzglas (K=1,4 W/m{sup 2}K), hochwertige Waermedaemmung der Bruestungen, aussenliegender Sonnenschutz mit motorbetaetigten Raffstoren, Radiatoren mit Thermostatventilen und einem Frischluft-Kuehldecken-System. Dieser Beitrag beschreibt die Vorgehensweise beim Bau der gesamten Klima- und Lueftungstechnik. (orig.)

  8. Advance care planning: the impact of Ceiling of Treatment plans in patients with Coordinate My Care.

    Science.gov (United States)

    Broadhurst, Helen Lucy; Droney, Joanne; Callender, Tom; Shaw, Amanda; Riley, Julia

    2018-03-22

    The aim of this evaluation is to describe the components and results of urgent care planning in Coordinate My Care (CMC), a digital clinical service for patients with life-limiting illness, for use if a patient is unable to make or express choices. Ceiling of treatment (CoT) plans were created detailing where the patient would like to receive their care and how aggressive medical interventions should be. A retrospective service evaluation was completed of all CMC records created between December 2015 and September 2016 (n=6854). CMC records were divided into two cohorts: those with a CoT plan and those without. The factors associated with these cohorts were reviewed including age, diagnosis, resuscitation status and preferences for place of death (PPD). Analysis of the non-mandatory free text section was carried out. Two-thirds of patients had recorded decisions about CoT. Regardless of which CoT option was chosen, for most patients, PPD was home or care home. Patients with a CoT plan were more likely to have a documented resuscitation status.Patients with a CoT were more likely to die in their PPD (82%vs71%, OR 1.79, pcare planning. Three facets of urgent care planning identified include PPD, CoT and resuscitation status. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Women's Health and Women's Leadership in Academic Medicine: Hitting the Same Glass Ceiling?

    Science.gov (United States)

    Morrissey, Claudia; Geller, Stacie E.

    2008-01-01

    Abstract The term “glass ceiling” refers to women's lack of advancement into leadership positions despite no visible barriers. The term has been applied to academic medicine for over a decade but has not previously been applied to the advancement of women's health. This paper discusses (1) the historical linking of the advances in women's health with women's leadership in academic medicine, (2) the slow progress of women into leadership in academic medicine, and (3) indicators that the advancement of women's health has stalled. We make the case that deeply embedded unconscious gender-based biases and assumptions underpin the stalled advancement of women on both fronts. We conclude with recommendations to promote progress beyond the apparent glass ceiling that is preventing further advancement of women's health and women leaders. We emphasize the need to move beyond “fixing the women” to a systemic, institutional approach that acknowledges and addresses the impact of unconscious, gender-linked biases that devalue and marginalize women and issues associated with women, such as their health. PMID:18954235

  10. Women in hospital medicine in the United Kingdom: glass ceiling, preference, prejudice or cohort effect?

    Science.gov (United States)

    McManus, I C; Sproston, K A

    2000-01-01

    To assess from official statistics whether there is evidence that the careers of women doctors in hospitals do not progress in the same way as those of men. The proportions of female hospital doctors overall (1963-96), and in the specialties of medicine, surgery, obstetrics and gynaecology, pathology, radiology/radiotherapy, anaesthetics and psychiatry (1974-1996) were examined. Additionally data were examined on career preferences and intentions from pre-registration house officers, final year medical students, and medical school applicants (1966-1991). Data were analysed according to cohort of entry to medical school to assess the extent of disproportionate promotion. The proportion of women in hospital career posts was largely explained by the rapidly increasing proportion of women entering medical school during the past three decades. In general there was little evidence for disproportionate promotion of women in hospital careers, although in surgery, hospital medicine and obstetrics and gynaecology, fewer women seemed to progress beyond the SHO grade, and in anaesthetics there were deficits of women at each career stage. Analyses of career preferences and intentions suggest that disproportionate promotion cannot readily be explained as differential choice by women. Although there is no evidence as such of a "glass ceiling" for women doctors in hospital careers, and the current paucity of women consultants primarily reflects historical trends in the numbers of women entering medical school, there is evidence in some cases of disproportionate promotion that is best interpreted as direct or indirect discrimination.

  11. Experimental research on the indoor temperature and humidity fields in radiant ceiling air-conditioning system under natural ventilation

    Science.gov (United States)

    Huang, Tao; Xiang, Yutong; Wang, Yonghong

    2017-05-01

    In this paper, the indoor temperature and humidity fields of the air in a metal ceiling radiant panel air conditioning system with fresh air under natural ventilation were researched. The temperature and humidity distributions at different height and different position were compared. Through the computation analysis of partial pressure of water vapor, the self-recovery characteristics of humidity after the natural ventilation was discussed.

  12. Development and evaluation of a ceiling ventilation system enhanced by solar photovoltaic thermal collectors and phase change materials

    International Nuclear Information System (INIS)

    Lin, Wenye; Ma, Zhenjun; Sohel, M. Imroz; Cooper, Paul

    2014-01-01

    Highlights: • A novel ceiling ventilation system enhanced by PVT and PCMs was proposed. • PCM was used to increase the local thermal mass and to serve as a storage unit. • The proposed system can enhance indoor thermal comfort in winter and summer. - Abstract: This paper presents the development and performance evaluation of a novel ceiling ventilation system integrated with solar photovoltaic thermal (PVT) collectors and phase change materials (PCMs). The PVT collectors are used to generate electricity and provide low grade heating and cooling energy for buildings by using winter daytime solar radiation and summer night-time sky radiative cooling, respectively. The PCM is integrated into the building ceiling as a part of the ceiling insulation and at the same time, as a centralized thermal energy storage to temporally store low grade energy collected from the PVT collectors. The performance of the proposed system was numerically evaluated based on a Solar Decathlon house using TRNSYS. The results showed that, in winter conditions, the proposed PVT–PCM integrated ventilation system can significantly improve the indoor thermal comfort of passive buildings without using air-conditioning systems with a maximum air temperature rise of 23.1 °C from the PVT collectors. Compared with the system using PCM but without using PVT collectors, the coefficient of thermal comfort enhancement in the kitchen, dining room and living room of the case building studied using the proposed system improved from almost zero to 0.9823 while the coefficient of thermal comfort enhancement in the study room improved from 0.0060 to 0.9921. In summer conditions, the proposed system can also enhance indoor thermal comfort through night-time sky radiative cooling

  13. Peak load pricing lowers generation costs

    International Nuclear Information System (INIS)

    Lande, R.H.

    1980-01-01

    Before a utility implements peak load pricing for different classes of consumers, the costs and the benefits should be compared. The methodology described enables a utility to determine whether peak load pricing should be introduced for specific users. Cost-benefit analyses for domestic consumers and commercial/industrial consumers, showing break-even points are presented. (author)

  14. Peak Shaving Considering Streamflow Uncertainties | Iwuagwu ...

    African Journals Online (AJOL)

    The main thrust of this paper is peak shaving with a Stochastic hydro model. In peak sharing, the amount of hydro energy scheduled may be a minimum but it serves to replace less efficient thermal units. The sample system is die Kainji hydro plant and the thermal units of the National Electric Power Authority. The random ...

  15. The peak in neutron powder diffraction

    International Nuclear Information System (INIS)

    Laar, B. van; Yelon, W.B.

    1984-01-01

    For the application of Rietveld profile analysis to neutron powder diffraction data a precise knowledge of the peak profile, in both shape and position, is required. The method now in use employs a Gaussian shaped profile with a semi-empirical asymmetry correction for low-angle peaks. The integrated intensity is taken to be proportional to the classical Lorentz factor calculated for the X-ray case. In this paper an exact expression is given for the peak profile based upon the geometrical dimensions of the diffractometer. It is shown that the asymmetry of observed peaks is well reproduced by this expression. The angular displacement of the experimental profile with respect to the nominal Bragg angle value is larger than expected. Values for the correction to the classical Lorentz factor for the integrated intensity are given. The exact peak profile expression has been incorporated into a Rietveld profile analysis refinement program. (Auth.)

  16. 26 CFR 1.103(n)-7T - Election to allocate State ceiling to certain facilities for local furnishing of electricity...

    Science.gov (United States)

    2010-04-01

    ... facilities for local furnishing of electricity (temporary). 1.103(n)-7T Section 1.103(n)-7T Internal Revenue... (CONTINUED) Items Specifically Excluded from Gross Income § 1.103(n)-7T Election to allocate State ceiling to... amount that would have been New York's State ceiling (as defined in section 103(n)(4) and A-1 of § 1.103...

  17. Cooling ceilings: Silent, comfortable and productive. Percentage of sickness absenteeism. Kuehldecken eroeffnen neue Moeglichkeiten: Still, behaglich und produktiv. Krankenstand von 11,8 auf 3,8% reduziert

    Energy Technology Data Exchange (ETDEWEB)

    Laege, F.K.

    1992-07-01

    This article is a report about the second symposium on cooling ceilings held in Essen, which had been organized by the technical institute for building ventilation. On the one hand the topic was the state of technology as well as the standardization have been treated, on the other hand, user experiences of non technicians have been reported. It was ascertained that the variety of references convinced the auditors. Germany has obviously the leading position for the construction of cooling ceilings. (BWI).

  18. Peak tree: a new tool for multiscale hierarchical representation and peak detection of mass spectrometry data.

    Science.gov (United States)

    Zhang, Peng; Li, Houqiang; Wang, Honghui; Wong, Stephen T C; Zhou, Xiaobo

    2011-01-01

    Peak detection is one of the most important steps in mass spectrometry (MS) analysis. However, the detection result is greatly affected by severe spectrum variations. Unfortunately, most current peak detection methods are neither flexible enough to revise false detection results nor robust enough to resist spectrum variations. To improve flexibility, we introduce peak tree to represent the peak information in MS spectra. Each tree node is a peak judgment on a range of scales, and each tree decomposition, as a set of nodes, is a candidate peak detection result. To improve robustness, we combine peak detection and common peak alignment into a closed-loop framework, which finds the optimal decomposition via both peak intensity and common peak information. The common peak information is derived and loopily refined from the density clustering of the latest peak detection result. Finally, we present an improved ant colony optimization biomarker selection method to build a whole MS analysis system. Experiment shows that our peak detection method can better resist spectrum variations and provide higher sensitivity and lower false detection rates than conventional methods. The benefits from our peak-tree-based system for MS disease analysis are also proved on real SELDI data.

  19. Modeling the probability distribution of peak discharge for infiltrating hillslopes

    Science.gov (United States)

    Baiamonte, Giorgio; Singh, Vijay P.

    2017-07-01

    Hillslope response plays a fundamental role in the prediction of peak discharge at the basin outlet. The peak discharge for the critical duration of rainfall and its probability distribution are needed for designing urban infrastructure facilities. This study derives the probability distribution, denoted as GABS model, by coupling three models: (1) the Green-Ampt model for computing infiltration, (2) the kinematic wave model for computing discharge hydrograph from the hillslope, and (3) the intensity-duration-frequency (IDF) model for computing design rainfall intensity. The Hortonian mechanism for runoff generation is employed for computing the surface runoff hydrograph. Since the antecedent soil moisture condition (ASMC) significantly affects the rate of infiltration, its effect on the probability distribution of peak discharge is investigated. Application to a watershed in Sicily, Italy, shows that with the increase of probability, the expected effect of ASMC to increase the maximum discharge diminishes. Only for low values of probability, the critical duration of rainfall is influenced by ASMC, whereas its effect on the peak discharge seems to be less for any probability. For a set of parameters, the derived probability distribution of peak discharge seems to be fitted by the gamma distribution well. Finally, an application to a small watershed, with the aim to test the possibility to arrange in advance the rational runoff coefficient tables to be used for the rational method, and a comparison between peak discharges obtained by the GABS model with those measured in an experimental flume for a loamy-sand soil were carried out.

  20. Multiscale peak detection in wavelet space.

    Science.gov (United States)

    Zhang, Zhi-Min; Tong, Xia; Peng, Ying; Ma, Pan; Zhang, Ming-Jin; Lu, Hong-Mei; Chen, Xiao-Qing; Liang, Yi-Zeng

    2015-12-07

    Accurate peak detection is essential for analyzing high-throughput datasets generated by analytical instruments. Derivatives with noise reduction and matched filtration are frequently used, but they are sensitive to baseline variations, random noise and deviations in the peak shape. A continuous wavelet transform (CWT)-based method is more practical and popular in this situation, which can increase the accuracy and reliability by identifying peaks across scales in wavelet space and implicitly removing noise as well as the baseline. However, its computational load is relatively high and the estimated features of peaks may not be accurate in the case of peaks that are overlapping, dense or weak. In this study, we present multi-scale peak detection (MSPD) by taking full advantage of additional information in wavelet space including ridges, valleys, and zero-crossings. It can achieve a high accuracy by thresholding each detected peak with the maximum of its ridge. It has been comprehensively evaluated with MALDI-TOF spectra in proteomics, the CAMDA 2006 SELDI dataset as well as the Romanian database of Raman spectra, which is particularly suitable for detecting peaks in high-throughput analytical signals. Receiver operating characteristic (ROC) curves show that MSPD can detect more true peaks while keeping the false discovery rate lower than MassSpecWavelet and MALDIquant methods. Superior results in Raman spectra suggest that MSPD seems to be a more universal method for peak detection. MSPD has been designed and implemented efficiently in Python and Cython. It is available as an open source package at .

  1. Nonlinear modeling and stability analysis of hydro-turbine governing system with sloping ceiling tailrace tunnel under load disturbance

    International Nuclear Information System (INIS)

    Guo, Wencheng; Yang, Jiandong; Wang, Mingjiang; Lai, Xu

    2015-01-01

    Highlights: • Novel nonlinear mathematical model of hydro-turbine governing system is proposed. • Hopf bifurcation analysis on the governing system is conducted. • Stability of the system under load disturbance is studied. • Influence of four factors on stability is analyzed. • Optimization methods of improving system stability are put forward. - Abstract: In order to overcome the problem of nonlinear dynamics of hydro-turbine governing system with sloping ceiling tailrace tunnel, which is caused by the interface movement of the free surface-pressurized flow in the tailrace tunnel, and the difficulty of analyzing the stability of system, this paper uses the Hopf bifurcation theory to study the stability of hydro-turbine governing system of hydropower station with sloping ceiling tailrace tunnel. Firstly, a novel and rational nonlinear mathematical model of the hydro-turbine governing system is proposed. This model contains the dynamic equation of pipeline system which can accurately describe the motion characteristics of the interface of free surface-pressurized flow in sloping ceiling tailrace tunnel. According to the nonlinear mathematical model, the existence and direction of Hopf bifurcation of the nonlinear dynamic system are analyzed. Furthermore, the algebraic criterion of the occurrence of Hopf bifurcation is derived. Then the stability domain and bifurcation diagram of hydro-turbine governing system are drawn by the algebraic criterion, and the characteristics of stability under different state parameters are investigated. Finally, the influence of step load value, ceiling slope angle and section form of tailrace tunnel and water depth at the interface in tailrace tunnel on stability are analyzed based on stable domain. The results indicate that: The Hopf bifurcation of hydro-turbine governing system with sloping ceiling tailrace tunnel is supercritical. The phase space trajectories of characteristic variables stabilize at the equilibrium points

  2. Fast clustering using adaptive density peak detection.

    Science.gov (United States)

    Wang, Xiao-Feng; Xu, Yifan

    2017-12-01

    Common limitations of clustering methods include the slow algorithm convergence, the instability of the pre-specification on a number of intrinsic parameters, and the lack of robustness to outliers. A recent clustering approach proposed a fast search algorithm of cluster centers based on their local densities. However, the selection of the key intrinsic parameters in the algorithm was not systematically investigated. It is relatively difficult to estimate the "optimal" parameters since the original definition of the local density in the algorithm is based on a truncated counting measure. In this paper, we propose a clustering procedure with adaptive density peak detection, where the local density is estimated through the nonparametric multivariate kernel estimation. The model parameter is then able to be calculated from the equations with statistical theoretical justification. We also develop an automatic cluster centroid selection method through maximizing an average silhouette index. The advantage and flexibility of the proposed method are demonstrated through simulation studies and the analysis of a few benchmark gene expression data sets. The method only needs to perform in one single step without any iteration and thus is fast and has a great potential to apply on big data analysis. A user-friendly R package ADPclust is developed for public use.

  3. Peak groundwater depletion in the High Plains Aquifer, projections from 1930 to 2110

    Science.gov (United States)

    Peak groundwater depletion from overtapping aquifers beyond recharge rates occurs as the depletion rate increases until a peak occurs followed by a decreasing trend as pumping equilibrates towards available recharge. The logistic equation of Hubbert’s study of peak oil is used to project measurement...

  4. 21 CFR 868.1860 - Peak-flow meter for spirometry.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Peak-flow meter for spirometry. 868.1860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1860 Peak-flow meter for spirometry. (a) Identification. A peak-flow meter for spirometry is a device used to measure a patient's...

  5. Superoxide dismutase levels and peak expiratory flow in asthmatic children

    Directory of Open Access Journals (Sweden)

    Arie Kurniasih

    2016-11-01

    Full Text Available Background Asthma is a chronic inflammatory process which involve variety of cells such as inflammatory mediators, reactive oxygen species (ROS, and cytokines. The inflammatory process would be exacerbated in the presence of oxidative stress. Superoxide dismutase (SOD is the first important enzyme to protect the respiratory tract against oxidative stress. The decreased of SOD has a correlation with increased of airway obstruction and bronchospasm. Objective To assess for a correlation between superoxide dismutase (SOD levels and peak expiratory flow, as well as to determine the impact of SOD levels for predicting asthma attacks. Methods We conducted a prospective cohort study at Dr. Sardjito Hospital, Yogyakarta, between February and April 2011 involving asthmatic children aged 5-18 years. Subjects’ serum SOD levels and peak expiratory flow were measured at the same time point. We then performed a prospective study following up on the same subjects to find out if they had a recurrent asthma attack within one month of the tests. We also reassessed their peak expiratory flow one month after blood specimens were obtained. Results Thirty-nine patients were enrolled in this study. There was no significant correlation between SOD level and peak expiratory flow [r=0.289; 95%CI -0.025 to 0.47; P=0.074]. However, older age was significantly associated with higher peak expiratory flow (=0.5; 95%CI 3.10 to 11.57; P=0.01. Lower levels of SOD increased the risk of asthma attacks in a month following the initial measurements (RR=5.5; 95%CI 1.6 to 18.9; P=0.009. Conclusion Superoxide dismutase (SOD level is not significantly associated with peak expiratory flow. However, we find a relationship between older age and higher peak expiratory flow and a relationship between lower SOD levels and risk of asthma attacks within one month following the tests.

  6. Variable threshold method for ECG R-peak detection.

    Science.gov (United States)

    Kew, Hsein-Ping; Jeong, Do-Un

    2011-10-01

    In this paper, a wearable belt-type ECG electrode worn around the chest by measuring the real-time ECG is produced in order to minimize the inconvenient in wearing. ECG signal is detected using a potential instrument system. The measured ECG signal is transmits via an ultra low power consumption wireless data communications unit to personal computer using Zigbee-compatible wireless sensor node. ECG signals carry a lot of clinical information for a cardiologist especially the R-peak detection in ECG. R-peak detection generally uses the threshold value which is fixed. There will be errors in peak detection when the baseline changes due to motion artifacts and signal size changes. Preprocessing process which includes differentiation process and Hilbert transform is used as signal preprocessing algorithm. Thereafter, variable threshold method is used to detect the R-peak which is more accurate and efficient than fixed threshold value method. R-peak detection using MIT-BIH databases and Long Term Real-Time ECG is performed in this research in order to evaluate the performance analysis.

  7. Research Opportunities at Storm Peak Laboratory

    Science.gov (United States)

    Hallar, A. G.; McCubbin, I. B.

    2006-12-01

    The Desert Research Institute (DRI) operates a high elevation facility, Storm Peak Laboratory (SPL), located on the west summit of Mt. Werner in the Park Range near Steamboat Springs, Colorado at an elevation of 3210 m MSL (Borys and Wetzel, 1997). SPL provides an ideal location for long-term research on the interactions of atmospheric aerosol and gas- phase chemistry with cloud and natural radiation environments. The ridge-top location produces almost daily transition from free tropospheric to boundary layer air which occurs near midday in both summer and winter seasons. Long-term observations at SPL document the role of orographically induced mixing and convection on vertical pollutant transport and dispersion. During winter, SPL is above cloud base 25% of the time, providing a unique capability for studying aerosol-cloud interactions (Borys and Wetzel, 1997). A comprehensive set of continuous aerosol measurements was initiated at SPL in 2002. SPL includes an office-type laboratory room for computer and instrumentation setup with outside air ports and cable access to the roof deck, a cold room for precipitation and cloud rime ice sample handling and ice crystal microphotography, a 150 m2 roof deck area for outside sampling equipment, a full kitchen and two bunk rooms with sleeping space for nine persons. The laboratory is currently well equipped for aerosol and cloud measurements. Particles are sampled from an insulated, 15 cm diameter manifold within approximately 1 m of its horizontal entry point through an outside wall. The 4 m high vertical section outside the building is capped with an inverted can to exclude large particles.

  8. Women in hospital medicine in the United Kingdom: glass ceiling, preference, prejudice or cohort effect?

    Science.gov (United States)

    McManus, I; Sproston, K

    2000-01-01

    OBJECTIVE—To assess from official statistics whether there is evidence that the careers of women doctors in hospitals do not progress in the same way as those of men.
DESIGN—The proportions of female hospital doctors overall (1963-96), and in the specialties of medicine, surgery, obstetrics and gynaecology, pathology, radiology/radiotherapy, anaesthetics and psychiatry (1974-1996) were examined. Additionally data were examined on career preferences and intentions from pre-registration house officers, final year medical students, and medical school applicants (1966-1991).
ANALYSIS—Data were analysed according to cohort of entry to medical school to assess the extent of disproportionate promotion.
RESULTS—The proportion of women in hospital career posts was largely explained by the rapidly increasing proportion of women entering medical school during the past three decades. In general there was little evidence for disproportionate promotion of women in hospital careers, although in surgery, hospital medicine and obstetrics and gynaecology, fewer women seemed to progress beyond the SHO grade, and in anaesthetics there were deficits of women at each career stage. Analyses of career preferences and intentions suggest that disproportionate promotion cannot readily be explained as differential choice by women.
CONCLUSIONS—Although there is no evidence as such of a "glass ceiling" for women doctors in hospital careers, and the current paucity of women consultants primarily reflects historical trends in the numbers of women entering medical school, there is evidence in some cases of disproportionate promotion that is best interpreted as direct or indirect discrimination.

 PMID:10692956

  9. The status of women at one academic medical center. Breaking through the glass ceiling.

    Science.gov (United States)

    Nickerson, K G; Bennett, N M; Estes, D; Shea, S

    1990-10-10

    Despite recent gains in admission to medical school and in obtaining junior faculty positions, women remain underrepresented at senior academic ranks and in leadership positions in medicine. This discrepancy has been interpreted as evidence of a "glass ceiling" that prevents all but a few exceptional women from gaining access to leadership positions. We analyzed data from Columbia University College of Physicians & Surgeons, New York, NY, for all faculty hired from 1969 through 1988 and found that the likelihood of promotion on the tenure track was 0.40 for women and 0.48 for men (ratio, 0.82; 95% confidence interval, 0.56 to 1.20); on the clinical track the likelihood of promotion was 0.75 for women and 0.72 for men (ratio, 1.04; 95% confidence interval, 0.56 to 1.94). Additional analysis of current faculty showed that in the academic year 1988-1989 the proportion of women at each tenure track rank at the College of Physicians & Surgeons equaled or exceeded the national proportion of women graduating from medical school, once allowance was made for the average time lag necessary to attain each rank. On the clinical track women were somewhat overrepresented, particularly at the junior rank. National data that describe medical school faculty, which combine tenure and clinical tracks, showed that in 1988 women were proportionately represented at each rank once the lead time from graduation was considered. We conclude that objective evidence shows that women can succeed and are succeeding in gaining promotions in academic medicine.

  10. In search of the glass ceiling: gender and recruitment to management in Norway's state bureaucracy.

    Science.gov (United States)

    Storvik, Aagoth Elise; Schøne, Pål

    2008-12-01

    There are still fewer female than male managers in Norway's state bureaucracy. This article asks if there are organizational barriers which prevent women from entering these positions. Is there really a glass ceiling, or must one look outside the organizational environment to find an explanation? Is it rather the case that the scarcity of female managers is caused by women's own preferences or their life situations outside work? Or do both contribute to the situation? The study shows that female managers are treated just as well as male managers in central parts of the state bureaucracy. Employers give equal shares of respect and attention to both genders. Female managers are encouraged to apply for the same number of jobs as men and are offered an equal number of jobs as men when they apply; in fact, women are offered more jobs than men, when one controls for the number of job applications. This indicates that organizational barriers are not the problem. The study also shows that there are no differences in work orientation between male and female managers. Female managers are just as ambitious as male managers. Nor do female managers find it more difficult than male managers to combine work and family life. So, how can one explain the low number of female managers? The study shows that one reason can be that female managers apply for management jobs less often than their male colleagues. The cause of this seems to be anticipated discrimination rather than lack of ambition or self-confidence. However, this slows down women's movement into higher management positions in the state bureaucracy.

  11. Peak load arrangements : Assessment of Nordel guidelines

    Energy Technology Data Exchange (ETDEWEB)

    2009-07-01

    Two Nordic countries, Sweden and Finland, have legislation that empowers the TSO to acquire designated peak load resources to mitigate the risk for shortage situations during the winter. In Denmark, the system operator procures resources to maintain a satisfactory level of security of supply. In Norway the TSO has set up a Regulation Power Option Market (RKOM) to secure a satisfactory level of operational reserves at all times, also in winter with high load demand. Only the arrangements in Finland and Sweden fall under the heading of Peak Load Arrangements defined in Nordel Guidelines. NordREG has been invited by the Electricity Market Group (EMG) to evaluate Nordel's proposal for 'Guidelines for transitional Peak Load Arrangements'. The EMG has also financed a study made by EC Group to support NordREG in the evaluation of the proposal. The study has been taken into account in NordREG's evaluation. In parallel to the EMG task, the Swedish regulator, the Energy Markets Inspectorate, has been given the task by the Swedish government to investigate a long term solution of the peak load issue. The Swedish and Finnish TSOs have together with Nord Pool Spot worked on finding a harmonized solution for activation of the peak load reserves in the market. An agreement accepted by the relevant authorities was reached in early January 2009, and the arrangement has been implemented since 19th January 2009. NordREG views that the proposed Nordel guidelines have served as a starting point for the presently agreed procedure. However, NordREG does not see any need to further develop the Nordel guidelines for peak load arrangements. NordREG agrees with Nordel that the market should be designed to solve peak load problems through proper incentives to market players. NordREG presumes that the relevant authorities in each country will take decisions on the need for any peak load arrangement to ensure security of supply. NordREG proposes that such decisions should be

  12. Size-independent peak shift between normal and upconversion ...

    Indian Academy of Sciences (India)

    2014-02-12

    Feb 12, 2014 ... In this article, we report size-dependent measurement of the shift in peak of upconversion photoluminescence spectra compared to that of normal photoluminescence using a 800 nm femtosecond laser and its second harmonic. It has been shown that the upconversion photoluminescence is always ...

  13. Characteristics of peaks of inhalation exposure to organic solvents

    NARCIS (Netherlands)

    Preller, L.; Burstyn, I.; Pater, N. de; Kromhout, H.

    2004-01-01

    Objectives: To determine which exposure metrics are sufficient to characterize 'peak' inhalation exposure to organic solvents (OS) during spraying operations. Methods: Personal exposure measurements (n = 27; duration 5-159 min) were collected during application of paints, primers, resins and glues

  14. Factors influencing peak expiratory flow in teenage boys | van ...

    African Journals Online (AJOL)

    Background. Peak expiratory flow (PEF) is a useful measure of pulmonary health status and is frequently utilised in asthm, management. Reduction in PEF is usually indicative of onset (of asthma symptoms. However, use can be made of PEF values only if normal values are known. The definition of normal range is always ...

  15. Bayesian Peak Picking for NMR Spectra

    KAUST Repository

    Cheng, Yichen

    2014-02-01

    Protein structure determination is a very important topic in structural genomics, which helps people to understand varieties of biological functions such as protein-protein interactions, protein–DNA interactions and so on. Nowadays, nuclear magnetic resonance (NMR) has often been used to determine the three-dimensional structures of protein in vivo. This study aims to automate the peak picking step, the most important and tricky step in NMR structure determination. We propose to model the NMR spectrum by a mixture of bivariate Gaussian densities and use the stochastic approximation Monte Carlo algorithm as the computational tool to solve the problem. Under the Bayesian framework, the peak picking problem is casted as a variable selection problem. The proposed method can automatically distinguish true peaks from false ones without preprocessing the data. To the best of our knowledge, this is the first effort in the literature that tackles the peak picking problem for NMR spectrum data using Bayesian method.

  16. Peak-Seeking Control for Trim Optimization

    Data.gov (United States)

    National Aeronautics and Space Administration — Innovators have developed a peak-seeking algorithm that can reduce drag and improve performance and fuel efficiency by optimizing aircraft trim in real time. The...

  17. Instream flow needs below peaking hydroelectric projects

    International Nuclear Information System (INIS)

    Milhous, R.T.

    1991-01-01

    This paper reports on a method developed to assist in the determination of instream flow needs below hydroelectric projects operated in a peaking mode. Peaking hydroelectric projects significantly change streamflow over a short period of time; consequently, any instream flow methodology must consider the dual flows associated with peaking projects. The dual flows are the lowest flow and the maximum generation flow of a peaking cycle. The methodology is based on elements of the Physical Habitat Simulation System of the U.S. Fish and Wildlife Service and uses habitat, rather than fish numbers or biomas, as at basic response variable. All aquatic animals are subject to the rapid changes in streamflow which cause rapid swings in habitat quality. Some aquatic organisms are relatively fixed in location in the stream while others can move when flows change. The habitat available from a project operated in peaking mode is considered to be the minimum habitat occurring during a cycle of habitat change. The methodology takes in to consideration that some aquatic animals can move and others cannot move during a peaking cycle

  18. Correlation Filter Learning Toward Peak Strength for Visual Tracking.

    Science.gov (United States)

    Sui, Yao; Wang, Guanghui; Zhang, Li

    2018-04-01

    This paper presents a novel visual tracking approach to correlation filter learning toward peak strength of correlation response. Previous methods leverage all features of the target and the immediate background to learn a correlation filter. Some features, however, may be distractive to tracking, like those from occlusion and local deformation, resulting in unstable tracking performance. This paper aims at solving this issue and proposes a novel algorithm to learn the correlation filter. The proposed approach, by imposing an elastic net constraint on the filter, can adaptively eliminate those distractive features in the correlation filtering. A new peak strength metric is proposed to measure the discriminative capability of the learned correlation filter. It is demonstrated that the proposed approach effectively strengthens the peak of the correlation response, leading to more discriminative performance than previous methods. Extensive experiments on a challenging visual tracking benchmark demonstrate that the proposed tracker outperforms most state-of-the-art methods.

  19. The Peak Pairs algorithm for strain mapping from HRTEM images

    Energy Technology Data Exchange (ETDEWEB)

    Galindo, Pedro L. [Departamento de Lenguajes y Sistemas Informaticos, CASEM, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain)], E-mail: pedro.galindo@uca.es; Kret, Slawomir [Institute of Physics, PAS, AL. Lotnikow 32/46, 02-668 Warsaw (Poland); Sanchez, Ana M. [Departamento de Ciencia de los Materiales e Ing. Metalurgica y Q. Inorganica, Facultad de Ciencias, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain); Laval, Jean-Yves [Laboratoire de Physique du Solide, UPR5 CNRS-ESPCI, Paris (France); Yanez, Andres; Pizarro, Joaquin; Guerrero, Elisa [Departamento de Lenguajes y Sistemas Informaticos, CASEM, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain); Ben, Teresa; Molina, Sergio I. [Departamento de Ciencia de los Materiales e Ing. Metalurgica y Q. Inorganica, Facultad de Ciencias, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain)

    2007-11-15

    Strain mapping is defined as a numerical image-processing technique that measures the local shifts of image details around a crystal defect with respect to the ideal, defect-free, positions in the bulk. Algorithms to map elastic strains from high-resolution transmission electron microscopy (HRTEM) images may be classified into two categories: those based on the detection of peaks of intensity in real space and the Geometric Phase approach, calculated in Fourier space. In this paper, we discuss both categories and propose an alternative real space algorithm (Peak Pairs) based on the detection of pairs of intensity maxima in an affine transformed space dependent on the reference area. In spite of the fact that it is a real space approach, the Peak Pairs algorithm exhibits good behaviour at heavily distorted defect cores, e.g. interfaces and dislocations. Quantitative results are reported from experiments to determine local strain in different types of semiconductor heterostructures.

  20. Pediatric Exercise Testing: Value and Implications of Peak Oxygen Uptake

    Directory of Open Access Journals (Sweden)

    Paolo T. Pianosi

    2017-01-01

    Full Text Available Peak oxygen uptake (peak V ˙ O 2 measured by clinical exercise testing is the benchmark for aerobic fitness. Aerobic fitness, estimated from maximal treadmill exercise, is a predictor of mortality in adults. Peak V ˙ O 2 was shown to predict longevity in patients aged 7–35 years with cystic fibrosis over 25 years ago. A surge of exercise studies in young adults with congenital heart disease over the past decade has revealed significant prognostic information. Three years ago, the first clinical trial in children with pulmonary arterial hypertension used peak V ˙ O 2 as an endpoint that likewise delivered clinically relevant data. Cardiopulmonary exercise testing provides clinicians with biomarkers and clinical outcomes, and researchers with novel insights into fundamental biological mechanisms reflecting an integrated physiological response hidden at rest. Momentum from these pioneering observations in multiple disease states should impel clinicians to employ similar methods in other patient populations; e.g., sickle cell disease. Advances in pediatric exercise science will elucidate new pathways that may identify novel biomarkers. Our initial aim of this essay is to highlight the clinical relevance of exercise testing to determine peak V ˙ O 2 , and thereby convince clinicians of its merit, stimulating future clinical investigators to broaden the application of exercise testing in pediatrics.

  1. Enhanced vegetation growth peak and its key mechanisms

    Science.gov (United States)

    Huang, K.; Xia, J.; Wang, Y.; Ahlström, A.; Schwalm, C.; Huntzinger, D. N.; Chen, J.; Cook, R. B.; Fang, Y.; Fisher, J. B.; Jacobson, A. R.; Michalak, A.; Schaefer, K. M.; Wei, Y.; Yan, L.; Luo, Y.

    2017-12-01

    It remains unclear that whether and how the vegetation growth peak has been shifted globally during the past three decades. Here we used two global datasets of gross primary productivity (GPP) and a satellite-derived Normalized Difference Vegetation Index (NDVI) to characterize recent changes in seasonal peak vegetation growth. The attribution of changes in peak growth to their driving factors was examined with several datasets. We demonstrated that the growth peak of global vegetation has been linearly increasing during the past three decades. About 65% of this trend is evenly explained by the expanding croplands (21%), rising atmospheric [CO2] (22%), and intensifying nitrogen deposition (22%). The contribution of expanding croplands to the peak growth trend was substantiated by measurements from eddy-flux towers, sun-induced chlorophyll fluorescence and a global database of plant traits, all of which demonstrated that croplands have a higher photosynthetic capacity than other vegetation types. The contribution of rising atmospheric [CO2] and nitrogen deposition are consistent with the positive response of leaf growth to elevated [CO2] (25%) and nitrogen addition (8%) from 346 manipulated experiments. The positive effect of rising atmospheric [CO2] was also well captured by 15 terrestrial biosphere models. However, most models underestimated the contributions of land-cover change and nitrogen deposition, but overestimated the positive effect of climate change.

  2. Limitation of peak fitting and peak shape methods for determination of activation energy of thermoluminescence glow peaks

    CERN Document Server

    Sunta, C M; Piters, T M; Watanabe, S

    1999-01-01

    This paper shows the limitation of general order peak fitting and peak shape methods for determining the activation energy of the thermoluminescence glow peaks in the cases in which retrapping probability is much higher than the recombination probability and the traps are filled up to near saturation level. Right values can be obtained when the trap occupancy is reduced by using small doses or by post-irradiation partial bleaching. This limitation in the application of these methods has not been indicated earlier. In view of the unknown nature of kinetics in the experimental samples, it is recommended that these methods of activation energy determination should be applied only at doses well below the saturation dose.

  3. Limitations and ceiling effects with circumferential minimally invasive correction techniques for adult scoliosis: analysis of radiological outcomes over a 7-year experience.

    Science.gov (United States)

    Anand, Neel; Baron, Eli M; Khandehroo, Babak

    2014-05-01

    Minimally invasive correction of adult scoliosis is a surgical method increasing in popularity. Limited data exist, however, as to how effective these methodologies are in achieving coronal plane and sagittal plane correction in addition to improving spinopelvic parameters. This study serves to quantify how much correction is possible with present circumferential minimally invasive surgical (cMIS) methods. Ninety patients were selected from a database of 187 patients who underwent cMIS scoliosis correction. All patients had a Cobb angle greater than 15°, 3 or more levels fused, and availability of preoperative and postoperative 36-inch standing radiographs. The mean duration of follow-up was 37 months. Preoperative and postoperative Cobb angle, sagittal vertical axis (SVA), coronal balance, lumbar lordosis (LL), and pelvic incidence (PI) were measured. Scatter plots were performed comparing the pre- and postoperative radiological parameters to calculate ceiling effects for SVA correction, Cobb angle correction, and PI-LL mismatch correction. The mean preoperative SVA value was 60 mm (range 11.5-151 mm); the mean postoperative value was 31 mm (range 0-84 mm). The maximum SVA correction achieved with cMIS techniques in any of the cases was 89 mm. In terms of coronal Cobb angle, a mean correction of 61% was noted, with a mean preoperative value of 35.8° (range 15°-74.7°) and a mean postoperative value of 13.9° (range 0°-32.5°). A ceiling effect for Cobb angle correction was noted at 42°. The ability to correct the PI-LL mismatch to 10° was limited to cases in which the preoperative PI-LL mismatch was 38° or less. Circumferential MIS techniques as currently used for the treatment of adult scoliosis have limitations in terms of their ability to achieve SVA correction and lumbar lordosis. When the preoperative SVA is greater than 100 mm and a substantial amount of lumbar lordosis is needed, as determined by spinopelvic parameter calculations, surgeons should

  4. Diagnóstico não invasivo da anemia fetal pela medida do pico de velocidade sistólica na dopplervelocimetria da artéria cerebral média Noninvasive fetal anemia diagnosis by middle cerebral artery peak systolic velocity waveform measurement

    Directory of Open Access Journals (Sweden)

    Marcos Roberto Taveira

    2004-09-01

    Full Text Available OBJETIVO: avaliar se existe associação entre a medida do pico de velocidade sistólica (PVS na dopplervelocimetria da artéria cerebral média (ACM e a concentração de hemoglobina fetal e determinar a sua capacidade diagnóstica. MÉTODOS: entre janeiro de 2000 e maio de 2003, 44 gestantes isoimunizadas foram submetidas a transfusão intra-uterina. Realizou-se estudo dopplervelocimétrico da ACM antes de cada transfusão fetal, sempre com intervalo inferior a 3 horas, antecedendo o procedimento. O PVS da ACM foi considerado alterado quando seu valor era superior a 1,5 múltiplo da mediana para a respectiva idade gestacional. A concentração de hemoglobina do cordão foi aferida antes de se iniciar a infusão de sangue, realizada no Hemocue® (B-Hemoglobin Photometer Hemocue AB; Angelholm, Sweden. O estudo estatístico foi feito pelo teste do chi2 e também foram calculados os valores de sensibilidade, especificidade, valores preditivos positivo e negativo. RESULTADOS: foram realizados 83 procedimentos, sendo que em 33 a hemoglobina fetal era inferior a 10,0 g/dL. Houve associação significativa entre as variáveis estudadas, pPURPOSE: to assess the correlation between middle cerebral artery peak systolic velocity and umbilical cord blood hemoglobin concentration and to determine its diagnostic value. PATIENTS AND METHODS: a cross-sectional prospective study was performed from January 2000 to May 2003. Forty-four isoimmunized pregnant women underwent a protocol for the identification of fetal hemolysis. When intrauterine transfusions were indicated, the umbilical cord blood hemoglobin concentration was measured at the beginning of the procedure. Each intrauterine transfusion preceded by Doppler velocimetry of the middle cerebral artery was regarded as one case, summing up eighty-three procedures. In all cases, the middle cerebral artery Doppler examinations were performed within the three hours preceding fetal blood sample collection. The

  5. Research paper no. 18. Trading rules for CO2 emission permits systems. A proposal for ceilings on quantities and prices

    International Nuclear Information System (INIS)

    Criqui, P.; Viguier, L.

    2000-01-01

    Tradable emission permit (TEP) systems for greenhouse gases (GHGs) as they could develop following the Kyoto Protocol - that is if they are limited to Annex B countries and are not bound by exchange regulations) - do not appear to be greatly acceptable today, either to the United States or to the European Union. The problem of the uncertainty related to the cost of reducing emissions is strongly highlighted in the United States: in fact, the approach adopted in the Kyoto Protocol, that of quantitative emissions targets, leaves the question of the reduction programme costs wide open. For the European Union, the unregulated TEP system is hardly acceptable because it would not guarantee that the principle of 'supplementarity' adopted in the Kyoto Protocol, that is, the fact that the purchase of permits should be in addition to action taken within each of the Annex B countries. The section two of this paper is an in-depth economic analysis of the european proposal for ''concrete ceilings''. The alternative proposals, formulated in the United States and relating more to permit price ceilings or''trigger price'', are examined in Section 3. After showing that each of the foregoing proposals could have consequences unacceptable to some or others of the parties to the Protocol, Section 4 offers the proposal of a hybrid formula for regulating the rights market. In fact, the main aim of this paper is to show that the implementation of a 'hybrid solution', consisting of limiting the volume of exchanges while at the same time introducing a TEP price ceiling, could provide a market regulation framework effect allowing the benefits of most of the economic advantages to be enjoyed and also having characteristics acceptable to the various parties from an environmental as well as from an international fairness point of view. (A.L.B.)

  6. Statistics of peaks of Gaussian random fields

    International Nuclear Information System (INIS)

    Bardeen, J.M.; Bond, J.R.; Kaiser, N.; Szalay, A.S.; Stanford Univ., CA; California Univ., Berkeley; Cambridge Univ., England; Fermi National Accelerator Lab., Batavia, IL)

    1986-01-01

    A set of new mathematical results on the theory of Gaussian random fields is presented, and the application of such calculations in cosmology to treat questions of structure formation from small-amplitude initial density fluctuations is addressed. The point process equation is discussed, giving the general formula for the average number density of peaks. The problem of the proper conditional probability constraints appropriate to maxima are examined using a one-dimensional illustration. The average density of maxima of a general three-dimensional Gaussian field is calculated as a function of heights of the maxima, and the average density of upcrossing points on density contour surfaces is computed. The number density of peaks subject to the constraint that the large-scale density field be fixed is determined and used to discuss the segregation of high peaks from the underlying mass distribution. The machinery to calculate n-point peak-peak correlation functions is determined, as are the shapes of the profiles about maxima. 67 references

  7. Peak Oil, threat or energy worlds' phantasm?

    International Nuclear Information System (INIS)

    Favennec, Jean-Pierre

    2011-01-01

    The concept of Peak Oil is based on the work of King Hubbert, a petroleum geologist who worked for Shell in the USA in the 1960's. Based on the fact that discoveries in America reached a maximum in the 1930's, he announced that American production would reach a maximum in 1969, which did actually occur. Geologists members of the Association for the Study of Peak Oil have extrapolated this result to a worldwide scale and, since oil discoveries reached a peak in the 1960's, argued that production will peak in the very near future. It is clear that hydrocarbon reserves are finite and therefore exhaustible. But little is known regarding the level of ultimate (i.e. total existing) reserves. There are probably very large reserves of non conventional oil in addition to the reserves of conventional oil. An increasing number of specialists put maximum production at less than 100 Mb/d more for geopolitical than physical reasons. Attainable peak production will probably vary from year to year and will depend on how crude oil prices develop

  8. Electric peak power forecasting by year 2025

    International Nuclear Information System (INIS)

    Alsayegh, O.A.; Al-Matar, O.A.; Fairouz, F.A.; Al-Mulla Ali, A.

    2005-01-01

    Peak power demand in Kuwait up to the year 2025 was predicted using an artificial neural network (ANN) model. The aim of the study was to investigate the effect of air conditioning (A/C) units on long-term power demand. Five socio-economic factors were selected as inputs for the simulation: (1) gross national product, (2) population, (3) number of buildings, (4) imports of A/C units, and (5) index of industrial production. The study used socio-economic data from 1978 to 2000. Historical data of the first 10 years of the studied time period were used to train the ANN. The electrical network was then simulated to forecast peak power for the following 11 years. The calculated error was then used for years in which power consumption data were not available. The study demonstrated that average peak power rates increased by 4100 MW every 5 years. Various scenarios related to changes in population, the number of buildings, and the quantity of A/C units were then modelled to estimate long-term peak power demand. Results of the study demonstrated that population had the strongest impact on future power demand, while the number of buildings had the smallest impact. It was concluded that peak power growth can be controlled through the use of different immigration policies, increased A/C efficiency, and the use of vertical housing. 7 refs., 2 tabs., 6 figs

  9. Electric peak power forecasting by year 2025

    Energy Technology Data Exchange (ETDEWEB)

    Alsayegh, O.A.; Al-Matar, O.A.; Fairouz, F.A.; Al-Mulla Ali, A. [Kuwait Inst. for Scientific Research, Kuwait City (Kuwait). Div. of Environment and Urban Development

    2005-07-01

    Peak power demand in Kuwait up to the year 2025 was predicted using an artificial neural network (ANN) model. The aim of the study was to investigate the effect of air conditioning (A/C) units on long-term power demand. Five socio-economic factors were selected as inputs for the simulation: (1) gross national product, (2) population, (3) number of buildings, (4) imports of A/C units, and (5) index of industrial production. The study used socio-economic data from 1978 to 2000. Historical data of the first 10 years of the studied time period were used to train the ANN. The electrical network was then simulated to forecast peak power for the following 11 years. The calculated error was then used for years in which power consumption data were not available. The study demonstrated that average peak power rates increased by 4100 MW every 5 years. Various scenarios related to changes in population, the number of buildings, and the quantity of A/C units were then modelled to estimate long-term peak power demand. Results of the study demonstrated that population had the strongest impact on future power demand, while the number of buildings had the smallest impact. It was concluded that peak power growth can be controlled through the use of different immigration policies, increased A/C efficiency, and the use of vertical housing. 7 refs., 2 tabs., 6 figs.

  10. Evaluation of Coating Removal and Aggressive Surface Removal Surface Technologies Applied to Concrete Walls, Brick Walls, and Concrete Ceilings

    International Nuclear Information System (INIS)

    Ebadian, M.A.; Lagos, L.E.

    1997-01-01

    The purpose of this investigation was to test and evaluate innovative and commercially available technologies for the surface decontamination of walls and ceilings. This investigation supports the DOE's objectives of reducing risks to human health and the environment through its restoration projects at FEMP and MEMP. This project was performed at the Hemispheric Center for Environmental Technology (HCET) at Florida International University (FIU), where one innovative and four commercially available decontamination technologies were evaluated under standard, non-nuclear testing conditions. The performance data generated by this project will assist DOE site managers in the selection of the safest, most efficient, and most cost-effective decontamination technologies to accomplish their remediation objectives

  11. The Glass Ceiling Conundrum: Illusory belief or Barriers that impede Women’s Career Advancement in the Workplace.

    OpenAIRE

    Rahim Ganiyu; Akintunde Oluwafemi; Afolabi Ademola; Okikiola Olatunji

    2018-01-01

    Given the preponderance of women in the workforce, it remained a puzzle why the entry of women into higher managerial positions remains restricted and why the syndrome of ‘think manager think male is growing progressively? The objective of this paper is to examine the glass ceiling conundrum with a view of ascertain how it limits women’s career advancement in the workplace. Extensive review of literature was presented and discussed. The paper revealed that women are not making it to th...

  12. Human perception of indoor environment generated by chilled ceiling combined with mixing ventilation or localised chilled beam under cooling mode

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Nygaard, Linette; Uth, Simon C.

    2014-01-01

    Experiments with 24 subjects were performed to study and compare the human perception of the indoor environment under summer conditions generated by a chilled ceiling combined with overhead mixing ventilation and localised chilled beam. The experiments were performed in an experimental chamber (4....../s and 16 0C. The localised chilled beam was installed over the workstation placed by the simulated window. During the experiment the subjects were delegated control over the primary flow rate supplied by the localised chilled beam. The whole exposure lasted 2 hours with 30 min of acclimatisation before...

  13. What is the peak stress in ceramic bar impacts?

    International Nuclear Information System (INIS)

    Simha, C. Hari Manoj; Bless, S.J.; Bedford, A.

    2000-01-01

    The bar impact experiment has been extensively used to characterize the high strain rate properties of high strength ceramics. In particular, alumina AD-99.5 has been widely studied; both stress gauge and VISAR bar impact data are available for this material. We have performed plate-on-bar impact experiments using this material in some novel configurations. An interface was introduced in the target bar (by cutting it) in the zone where the material fails by axial splitting. Such experiments resulted in a dramatic drop in the peak stress measured in the experiment, when compared to experiments with no interface. We show that the damage kinetics in tension influence these measurements. Since the peak stress is dependent on the damage kinetics we conclude that the measurement cannot be correlated to some intrinsic strength of the ceramic

  14. SPANISH PEAKS WILDERNESS STUDY AREA, COLORADO.

    Science.gov (United States)

    Budding, Karin E.; Kluender, Steven E.

    1984-01-01

    A geologic and geochemical investigation and a survey of mines and prospects were conducted to evaluate the mineral-resource potential of the Spanish Peaks Wilderness Study Area, Huerfano and Las Animas Counties, in south-central Colorado. Anomalous gold, silver, copper, lead, and zinc concentrations in rocks and in stream sediments from drainage basins in the vicinity of the old mines and prospects on West Spanish Peak indicate a substantiated mineral-resource potential for base and precious metals in the area surrounding this peak; however, the mineralized veins are sparse, small in size, and generally low in grade. There is a possibility that coal may underlie the study area, but it would be at great depth and it is unlikely that it would have survived the intense igneous activity in the area. There is little likelihood for the occurrence of oil and gas because of the lack of structural traps and the igneous activity.

  15. Analysis of fuel end-temperature peaking

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Z.; Jiang, Q.; Lai, L.; Shams, M. [CANDU Energy Inc., Fuel Engineering Dept., Mississauga, Ontario (Canada)

    2013-07-01

    During normal operation and refuelling of CANDU® fuel, fuel temperatures near bundle ends will increase due to a phenomenon called end flux peaking. Similar phenomenon would also be expected to occur during a postulated large break LOCA event. The end flux peaking in a CANDU fuel element is due to the fact that neutron flux is higher near a bundle end, in contact with a neighbouring bundle or close to heavy water coolant, than in the bundle mid-plane, because of less absorption of thermal neutrons by Zircaloy or heavy water than by the UO{sub 2} material. This paper describes Candu Energy experience in analysing behaviour of bundle due to end flux peaking using fuel codes FEAT, ELESTRES and ELOCA. (author)

  16. Hurricane Mitch: Peak Discharge for Selected River Reachesin Honduras

    Science.gov (United States)

    Smith, Mark E.; Phillips, Jeffrey V.; Spahr, Norman E.

    2002-01-01

    Hurricane Mitch began as a tropical depression in the Caribbean Sea on 22 October 1998. By 26 October, Mitch had strengthened to a Category 5 storm as defined by the Saffir-Simpson Hurricane Scale (National Climate Data Center, 1999a), and on 27 October was threatening the northern coast of Honduras (fig. 1). After making landfall 2 days later (29 October), the storm drifted south and west across Honduras, wreaking destruction throughout the country before reaching the Guatemalan border on 31 October. According to the National Climate Data Center of the National Oceanic and Atmospheric Administration (National Climate Data Center, 1999b), Hurricane Mitch ranks among the five strongest storms on record in the Atlantic Basin in terms of its sustained winds, barometric pressure, and duration. Hurricane Mitch also was one of the worst Atlantic storms in terms of loss of life and property. The regionwide death toll was estimated to be more than 9,000; thousands of people were reported missing. Economic losses in the region were more than $7.5 billion (U.S. Agency for International Development, 1999). Honduras suffered the most widespread devastation during the storm. More than 5,000 deaths, and economic losses of more than $4 billion, were reported by the Government of Honduras. Honduran officials estimated that Hurricane Mitch destroyed 50 years of economic development. In addition to the human and economic losses, intense flooding and landslides scarred the Honduran landscape - hydrologic and geomorphologic processes throughout the country likely will be affected for many years. As part of the U.S. Government's response to the disaster, the U.S. Geological Survey (USGS) conducted post-flood measurements of peak discharge at 16 river sites throughout Honduras (fig. 2). Such measurements, termed 'indirect' measurements, are used to determine peak flows when direct measurements (using current meters or dye studies, for example) cannot be made. Indirect measurements of

  17. Osteoporosis: Peak Bone Mass in Women

    Science.gov (United States)

    ... bone density are seen even during childhood and adolescence. Hormonal factors. The hormone estrogen has an effect on peak bone mass. For example, women who had their first menstrual cycle at an early age and those who use oral contraceptives, which contain estrogen, often have high bone mineral ...

  18. Facility Location with Double-peaked Preferences

    DEFF Research Database (Denmark)

    Filos-Ratsikas, Aris; Li, Minming; Zhang, Jie

    2015-01-01

    ; this makes the problem essentially more challenging. As our main contribution, we present a simple truthful-in-expectation mechanism that achieves an approximation ratio of 1+b=c for both the social and the maximum, cost, where b is the distance of the agent from the peak and c is the minimum cost...

  19. Robust Peak Recognition in Intracranial Pressure Signals

    Directory of Open Access Journals (Sweden)

    Bergsneider Marvin

    2010-10-01

    Full Text Available Abstract Background The waveform morphology of intracranial pressure pulses (ICP is an essential indicator for monitoring, and forecasting critical intracranial and cerebrovascular pathophysiological variations. While current ICP pulse analysis frameworks offer satisfying results on most of the pulses, we observed that the performance of several of them deteriorates significantly on abnormal, or simply more challenging pulses. Methods This paper provides two contributions to this problem. First, it introduces MOCAIP++, a generic ICP pulse processing framework that generalizes MOCAIP (Morphological Clustering and Analysis of ICP Pulse. Its strength is to integrate several peak recognition methods to describe ICP morphology, and to exploit different ICP features to improve peak recognition. Second, it investigates the effect of incorporating, automatically identified, challenging pulses into the training set of peak recognition models. Results Experiments on a large dataset of ICP signals, as well as on a representative collection of sampled challenging ICP pulses, demonstrate that both contributions are complementary and significantly improve peak recognition performance in clinical conditions. Conclusion The proposed framework allows to extract more reliable statistics about the ICP waveform morphology on challenging pulses to investigate the predictive power of these pulses on the condition of the patient.

  20. Liquid waste processing at Comanche Peak

    International Nuclear Information System (INIS)

    Hughes-Edwards, L.M.; Edwards, J.M.

    1996-01-01

    This article describes the radioactive waste processing at Comanche Peak Steam Electric Station. Topics covered are the following: Reduction of liquid radioactive discharges (system leakage, outage planning); reduction of waste resin generation (waste stream segregation, processing methodology); reduction of activity released and off-site dose. 8 figs., 2 tabs

  1. Avoiding the False Peaks in Correlation Discrimination

    International Nuclear Information System (INIS)

    Awwal, A.S.

    2009-01-01

    Fiducials imprinted on laser beams are used to perform video image based alignment of the 192 laser beams in the National Ignition Facility (NIF) of Lawrence Livermore National Laboratory. In many video images, matched filtering is used to detect the location of these fiducials. Generally, the highest correlation peak is used to determine the position of the fiducials. However, when the signal to-be-detected is very weak compared to the noise, this approach totally breaks down. The highest peaks act as traps for false detection. The active target images used for automatic alignment in the National Ignition Facility are examples of such images. In these images, the fiducials of interest exhibit extremely low intensity and contrast, surrounded by high intensity reflection from metallic objects. Consequently, the highest correlation peaks are caused by these bright objects. In this work, we show how the shape of the correlation is exploited to isolate the valid matches from hundreds of invalid correlation peaks, and therefore identify extremely faint fiducials under very challenging imaging conditions

  2. Hubbert's Peak: the Impending World oil Shortage

    Science.gov (United States)

    Deffeyes, K. S.

    2004-12-01

    Global oil production will probably reach a peak sometime during this decade. After the peak, the world's production of crude oil will fall, never to rise again. The world will not run out of energy, but developing alternative energy sources on a large scale will take at least 10 years. The slowdown in oil production may already be beginning; the current price fluctuations for crude oil and natural gas may be the preamble to a major crisis. In 1956, the geologist M. King Hubbert predicted that U.S. oil production would peak in the early 1970s.1 Almost everyone, inside and outside the oil industry, rejected Hubbert's analysis. The controversy raged until 1970, when the U.S. production of crude oil started to fall. Hubbert was right. Around 1995, several analysts began applying Hubbert's method to world oil production, and most of them estimate that the peak year for world oil will be between 2004 and 2008. These analyses were reported in some of the most widely circulated sources: Nature, Science, and Scientific American.2 None of our political leaders seem to be paying attention. If the predictions are correct, there will be enormous effects on the world economy. Even the poorest nations need fuel to run irrigation pumps. The industrialized nations will be bidding against one another for the dwindling oil supply. The good news is that we will put less carbon dioxide into the atmosphere. The bad news is that my pickup truck has a 25-gallon tank.

  3. Peak quantification in surface-enhanced laser desorption/ionization by using mixture models

    NARCIS (Netherlands)

    Dijkstra, Martijn; Roelofsen, Han; Vonk, Roel J.; Jansen, Ritsert C.

    2006-01-01

    Surface-enhanced laser desorption/ionization (SELDI) time of flight (TOF) is a mass spectrometry technology for measuring the composition of a sampled protein mixture. A mass spectrum contains peaks corresponding to proteins in the sample. The peak areas are proportional to the measured

  4. Coupling ant colony and the degraded ceiling algorithm for the redundancy allocation problem of series-parallel systems

    International Nuclear Information System (INIS)

    Nahas, Nabil; Nourelfath, Mustapha; Ait-Kadi, Daoud

    2007-01-01

    The redundancy allocation problem (RAP) is a well known NP-hard problem which involves the selection of elements and redundancy levels to maximize system reliability given various system-level constraints. As telecommunications and internet protocol networks, manufacturing and power systems are becoming more and more complex, while requiring short developments schedules and very high reliability, it is becoming increasingly important to develop efficient solutions to the RAP. This paper presents an efficient algorithm to solve this reliability optimization problem. The idea of a heuristic approach design is inspired from the ant colony meta-heuristic optimization method and the degraded ceiling local search technique. Our hybridization of the ant colony meta-heuristic with the degraded ceiling performs well and is competitive with the best-known heuristics for redundancy allocation. Numerical results for the 33 test problems from previous research are reported and compared. The solutions found by our approach are all better than or are in par with the well-known best solutions

  5. Simulation Study of Active Ceilings with Phase Change Material in Office Buildings for Different National Building Regulations

    DEFF Research Database (Denmark)

    Farhan, Hajan; Stefansen, Casper; Bourdakis, Eleftherios

    2018-01-01

    The aim of this study was to examine the performance of phase change material (PCM) in active ceilings for an office room under different Danish building regulations for both heating and cooling purposes. A model of a two-person office room was simulated with the only heating and cooling source...... being radiant ceiling panels containing PCM. The target was to reduce energy use for the simulation models and still meet the recommended criteria of Category II for the European Standard EN 15251:2007 namely, 23°C – 26°C (73.4°F – 78.8°F) during summer and between 20°C – 24°C (68.0°F – 73.4°F) during...... winter. The office model was simulated for a whole year and analyzed for three Danish building regulations BR10 (2010), BR15 (2015) and BR20 (2020). The results show that the indoor environment was within the desired Category II, according to EN 15251 for the whole occupancy period. The predicted...

  6. The peak in anomalous magnetic viscosity

    International Nuclear Information System (INIS)

    Collocott, S.J.; Watterson, P.A.; Tan, X.H.; Xu, H.

    2014-01-01

    Anomalous magnetic viscosity, where the magnetization as a function of time exhibits non-monotonic behaviour, being seen to increase, reach a peak, and then decrease, is observed on recoil lines in bulk amorphous ferromagnets, for certain magnetic prehistories. A simple geometrical approach based on the motion of the state line on the Preisach plane gives a theoretical framework for interpreting non-monotonic behaviour and explains the origin of the peak. This approach gives an expression for the time taken to reach the peak as a function of the applied (or holding) field. The theory is applied to experimental data for bulk amorphous ferromagnet alloys of composition Nd 60−x Fe 30 Al 10 Dy x , x = 0, 1, 2, 3 and 4, and it gives a reasonable description of the observed behaviour. The role played by other key magnetic parameters, such as the intrinsic coercivity and fluctuation field, is also discussed. When the non-monotonic behaviour of the magnetization of a number of alloys is viewed in the context of the model, features of universal behaviour emerge, that are independent of alloy composition. - Highlights: • Development of a simple geometrical model based on the Preisach model which gives a complete explanation of the peak in the magnetic viscosity. • Geometrical approach is extended by considering equations that govern the motion of the state line. • The model is used to deduce the relationship between the holding field and the time it takes to reach the peak. • The model is tested with experimental results for a range of Nd–Fe–Al–Dy bulk amorphous ferromagnets. • There is good agreement between the model and the experimental data

  7. The spatial resolution of epidemic peaks.

    Directory of Open Access Journals (Sweden)

    Harriet L Mills

    2014-04-01

    Full Text Available The emergence of novel respiratory pathogens can challenge the capacity of key health care resources, such as intensive care units, that are constrained to serve only specific geographical populations. An ability to predict the magnitude and timing of peak incidence at the scale of a single large population would help to accurately assess the value of interventions designed to reduce that peak. However, current disease-dynamic theory does not provide a clear understanding of the relationship between: epidemic trajectories at the scale of interest (e.g. city; population mobility; and higher resolution spatial effects (e.g. transmission within small neighbourhoods. Here, we used a spatially-explicit stochastic meta-population model of arbitrary spatial resolution to determine the effect of resolution on model-derived epidemic trajectories. We simulated an influenza-like pathogen spreading across theoretical and actual population densities and varied our assumptions about mobility using Latin-Hypercube sampling. Even though, by design, cumulative attack rates were the same for all resolutions and mobilities, peak incidences were different. Clear thresholds existed for all tested populations, such that models with resolutions lower than the threshold substantially overestimated population-wide peak incidence. The effect of resolution was most important in populations which were of lower density and lower mobility. With the expectation of accurate spatial incidence datasets in the near future, our objective was to provide a framework for how to use these data correctly in a spatial meta-population model. Our results suggest that there is a fundamental spatial resolution for any pathogen-population pair. If underlying interactions between pathogens and spatially heterogeneous populations are represented at this resolution or higher, accurate predictions of peak incidence for city-scale epidemics are feasible.

  8. Demand Side Management: An approach to peak load smoothing

    Science.gov (United States)

    Gupta, Prachi

    A preliminary national-level analysis was conducted to determine whether Demand Side Management (DSM) programs introduced by electric utilities since 1992 have made any progress towards their stated goal of reducing peak load demand. Estimates implied that DSM has a very small effect on peak load reduction and there is substantial regional and end-user variability. A limited scholarly literature on DSM also provides evidence in support of a positive effect of demand response programs. Yet, none of these studies examine the question of how DSM affects peak load at the micro-level by influencing end-users' response to prices. After nearly three decades of experience with DSM, controversy remains over how effective these programs have been. This dissertation considers regional analyses that explore both demand-side solutions and supply-side interventions. On the demand side, models are estimated to provide in-depth evidence of end-user consumption patterns for each North American Electric Reliability Corporation (NERC) region, helping to identify sectors in regions that have made a substantial contribution to peak load reduction. The empirical evidence supports the initial hypothesis that there is substantial regional and end-user variability of reductions in peak demand. These results are quite robust in rapidly-urbanizing regions, where air conditioning and lighting load is substantially higher, and regions where the summer peak is more pronounced than the winter peak. It is also evident from the regional experiences that active government involvement, as shaped by state regulations in the last few years, has been successful in promoting DSM programs, and perhaps for the same reason we witness an uptick in peak load reductions in the years 2008 and 2009. On the supply side, we estimate the effectiveness of DSM programs by analyzing the growth of capacity margin with the introduction of DSM programs. The results indicate that DSM has been successful in offsetting the

  9. Interpretation of the peak areas in gamma-ray spectra that have a large relative uncertainty

    International Nuclear Information System (INIS)

    Korun, M.; Maver Modec, P.; Vodenik, B.

    2012-01-01

    Empirical evidence is provided that the areas of peaks having a relative uncertainty in excess of 30% are overestimated. This systematic influence is of a statistical nature and originates in way the peak-analyzing routine recognizes the small peaks. It is not easy to detect this influence since it is smaller than the peak-area uncertainty. However, the systematic influence can be revealed in repeated measurements under the same experimental conditions, e.g., in background measurements. To evaluate the systematic influence, background measurements were analyzed with the peak-analyzing procedure described by Korun et al. (2008). The magnitude of the influence depends on the relative uncertainty of the peak area and may amount, in the conditions used in the peak analysis, to a factor of 5 at relative uncertainties exceeding 60%. From the measurements, the probability for type-II errors, as a function of the relative uncertainty of the peak area, was extracted. This probability is near zero below an uncertainty of 30% and rises to 90% at uncertainties exceeding 50%. - Highlights: ► A systematic influence affecting small peak areas in gamma-ray spectra is described. ► The influence originates in the peak locating procedure, using a pre-determined sensitivity. ► The predetermined sensitivity makes peak areas with large uncertainties to be overestimated. ► The influence depends on the relative uncertainty of the number of counts in the peak. ► Corrections exceeding a factor of 3 are attained at peak area uncertainties exceeding 60%.

  10. Genetic and Dynamic Analyses of Murine Peak Bone Density

    Science.gov (United States)

    1999-10-01

    bone density in mice. Femurs from young adult B6, C3H, and CAST females at 4 months of age were measured by pQCT (XCT-960M, Norland Med Sys., Ft...progenitor strains - B6, C3H, and CAST - showed that adult skeletal peak BMD was established at 4 months. Therefore, F2 mice were necropsied at 4...calcium depletion causes hypocalcemia , which leads to secondary hyperparathyroidism, subsequently resulting in increased bone resorption. Conversely

  11. Peak-counts blood flow model-errors and limitations

    International Nuclear Information System (INIS)

    Mullani, N.A.; Marani, S.K.; Ekas, R.D.; Gould, K.L.

    1984-01-01

    The peak-counts model has several advantages, but its use may be limited due to the condition that the venous egress may not be negligible at the time of peak-counts. Consequently, blood flow measurements by the peak-counts model will depend on the bolus size, bolus duration, and the minimum transit time of the bolus through the region of interest. The effect of bolus size on the measurement of extraction fraction and blood flow was evaluated by injecting 1 to 30ml of rubidium chloride in the femoral vein of a dog and measuring the myocardial activity with a beta probe over the heart. Regional blood flow measurements were not found to vary with bolus sizes up to 30ml. The effect of bolus duration was studied by injecting a 10cc bolus of tracer at different speeds in the femoral vein of a dog. All intravenous injections undergo a broadening of the bolus duration due to the transit time of the tracer through the lungs and the heart. This transit time was found to range from 4-6 second FWHM and dominates the duration of the bolus to the myocardium for up to 3 second injections. A computer simulation has been carried out in which the different parameters of delay time, extraction fraction, and bolus duration can be changed to assess the errors in the peak-counts model. The results of the simulations show that the error will be greatest for short transit time delays and for low extraction fractions

  12. Combined effect of upstream surge chamber and sloping ceiling tailrace tunnel on dynamic performance of turbine regulating system of hydroelectric power plant

    International Nuclear Information System (INIS)

    Guo, Wencheng; Yang, Jiandong

    2017-01-01

    Highlights: • Nonlinear mathematical model and Hopf bifurcation analysis of turbine regulating system are presented. • Dynamic performance of turbine regulating system under 0.5 times Thoma sectional area is analyzed and a novel dynamic performance is revealed. • Relationship between two bifurcation lines and wave superposition is studied. • Combined effect mechanisms of upstream surge chamber and sloping ceiling tailrace tunnel on stability are revealed and optimization methods are proposed. - Abstract: Based on the nonlinear mathematical model of the turbine regulating system of hydroelectric power plant with upstream surge chamber and sloping ceiling tailrace tunnel and the Hopf bifurcation theory, this paper firstly studies the dynamic performance of the turbine regulating system under 0.5 times Thoma sectional area of surge chamber, and reveals a novel dynamic performance. Then, the relationship between the two bifurcation lines and the wave superposition of upstream surge chamber and sloping ceiling tailrace tunnel is analyzed. Finally, the effect mechanisms of the wave superposition on the system stability are investigated, and the methods to improve the system stability are proposed. The results indicate that: Under the combined effect of upstream surge chamber and sloping ceiling tailrace tunnel, the dynamic performance of the turbine regulating system of hydroelectric power plant shows an obvious difference on the two sides of the critical sectional area of surge chamber. There are two bifurcation lines for the condition of 0.5 times Thoma sectional area, i.e. Bifurcation line 1 and Bifurcation line 2, which represent the stability characteristics of the flow oscillation of “penstock-sloping ceiling tailrace tunnel” and the water-level fluctuation in upstream surge chamber, respectively. The stable domain of the system is determined by Bifurcation line 2. The effect of upstream surge chamber mainly depends on its sectional area, while the

  13. Daytime space cooling with phase change material ceiling panels discharged using rooftop photovoltaic/thermal panels and night-time ventilation

    DEFF Research Database (Denmark)

    Bourdakis, Eleftherios; Pean, Thibault Quentin; Gennari, Luca

    2016-01-01

    The possibility of using photovoltaic/thermal panels for producing cold water through the process of night-time radiative cooling was experimentally examined. The cold water was used to discharge phase change material in ceiling panels in a climatic chamber. Both night-time radiative cooling...... the photovoltaic/thermal varied from 56% to 122%. The phase change material ceiling panels were thus, capable of providing an acceptable thermal environment and the photovoltaic/thermal panels were able to provide most of the required electricity and cold water needed for cooling....

  14. Numerical analysis of the potential of using light radiant ceilings in combination with diffuse ventilation to achieve thermal comfort in NZEB buildings

    DEFF Research Database (Denmark)

    Krusaa, Marie Rugholm; Hviid, Christian Anker; Kolarik, Jakub

    ceiling panels. These panels make it possible to combine the heating/cooling ceiling with the diffuse ventilation method. The diffuse ventilation method or leak ventilation use larger surfaces to provide air into the room instead of diffusers. An office building is investigated an analysed on an annual...... basis in the dynamic building simulation tool IDA Indoor Climate and Energy (IDA ICE). The office building contains both offices and meeting rooms. Worst-case scenarios are investigated in the office building considering heat gains, solar gains and the temperature offset between supply water temperature...

  15. Stereotactic Bragg peak proton radiosurgery method

    International Nuclear Information System (INIS)

    Kjellberg, R.N.

    1979-01-01

    A brief description of the technical aspects of a stereotactic Bragg peak proton radiosurgical method for the head is presented. The preparatory radiographic studies are outlined and the stereotactic instrument and positioning of the patient are described. The instrument is so calibrated that after corrections for soft tissue and bone thickness, the Bragg peak superimposes upon the intracranial target. The head is rotated at specific intervals to allow predetermined portals of access for the beam path, all of which converge on the intracranial target. Normally, portals are arranged to oppose and overlap from both sides of the head. Using a number of beams (in sequence) on both sides of the head, the target dose is far greater than the path dose. The procedure normally takes 3/2-2 hours, following which the patient can walk away. (Auth./C.F.)

  16. Central peaking of magnetized gas discharges

    International Nuclear Information System (INIS)

    Chen, Francis F.; Curreli, Davide

    2013-01-01

    Partially ionized gas discharges used in industry are often driven by radiofrequency (rf) power applied at the periphery of a cylinder. It is found that the plasma density n is usually flat or peaked on axis even if the skin depth of the rf field is thin compared with the chamber radius a. Previous attempts at explaining this did not account for the finite length of the discharge and the boundary conditions at the endplates. A simple 1D model is used to focus on the basic mechanism: the short-circuit effect. It is found that a strong electric field (E-field) scaled to electron temperature T e , drives the ions inward. The resulting density profile is peaked on axis and has a shape independent of pressure or discharge radius. This “universal” profile is not affected by a dc magnetic field (B-field) as long as the ion Larmor radius is larger than a

  17. Peak Oil, Food Systems, and Public Health

    Science.gov (United States)

    Parker, Cindy L.; Kirschenmann, Frederick L.; Tinch, Jennifer; Lawrence, Robert S.

    2011-01-01

    Peak oil is the phenomenon whereby global oil supplies will peak, then decline, with extraction growing increasingly costly. Today's globalized industrial food system depends on oil for fueling farm machinery, producing pesticides, and transporting goods. Biofuels production links oil prices to food prices. We examined food system vulnerability to rising oil prices and the public health consequences. In the short term, high food prices harm food security and equity. Over time, high prices will force the entire food system to adapt. Strong preparation and advance investment may mitigate the extent of dislocation and hunger. Certain social and policy changes could smooth adaptation; public health has an essential role in promoting a proactive, smart, and equitable transition that increases resilience and enables adequate food for all. PMID:21778492

  18. Hanford Site peak gust wind speeds

    International Nuclear Information System (INIS)

    Ramsdell, J.V.

    1998-01-01

    Peak gust wind data collected at the Hanford Site since 1945 are analyzed to estimate maximum wind speeds for use in structural design. The results are compared with design wind speeds proposed for the Hanford Site. These comparisons indicate that design wind speeds contained in a January 1998 advisory changing DOE-STD-1020-94 are excessive for the Hanford Site and that the design wind speeds in effect prior to the changes are still appropriate for the Hanford Site

  19. Commodity hydrogen from off-peak electricity

    Energy Technology Data Exchange (ETDEWEB)

    Darrow, K.; Biederman, N.; Konopka, A.

    1977-01-01

    This paper considers the use of off-peak electrical power as an energy source for the electrolytic production of hydrogen. The present industrial uses for hydrogen are examined to determine if hydrogen produced in this fashion would be competitive with the industry's onsite production or existing hydrogen prices. The paper presents a technical and economic feasibility analysis of the various components required and of the operation of the system as a whole including production, transmission, storage, and markets.

  20. Ionoacoustic characterization of the proton Bragg peak with submillimeter accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Assmann, W., E-mail: walter.assmann@lmu.de; Reinhardt, S.; Lehrack, S.; Edlich, A.; Thirolf, P. G.; Parodi, K. [Department for Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, Garching 85748 (Germany); Kellnberger, S.; Omar, M.; Ntziachristos, V. [Institute for Biological and Medical Imaging, Technische Universität München and Helmholtz Zentrum München, Ingolstädter Landstrasse 1, Neuherberg 85764 (Germany); Moser, M.; Dollinger, G. [Institute for Applied Physics and Measurement Technology, Universität der Bundeswehr, Werner-Heisenberg-Weg 39, Neubiberg 85577 (Germany)

    2015-02-15

    Purpose: Range verification in ion beam therapy relies to date on nuclear imaging techniques which require complex and costly detector systems. A different approach is the detection of thermoacoustic signals that are generated due to localized energy loss of ion beams in tissue (ionoacoustics). Aim of this work was to study experimentally the achievable position resolution of ionoacoustics under idealized conditions using high frequency ultrasonic transducers and a specifically selected probing beam. Methods: A water phantom was irradiated by a pulsed 20 MeV proton beam with varying pulse intensity and length. The acoustic signal of single proton pulses was measured by different PZT-based ultrasound detectors (3.5 and 10 MHz central frequencies). The proton dose distribution in water was calculated by Geant4 and used as input for simulation of the generated acoustic wave by the matlab toolbox k-WAVE. Results: In measurements from this study, a clear signal of the Bragg peak was observed for an energy deposition as low as 10{sup 12} eV. The signal amplitude showed a linear increase with particle number per pulse and thus, dose. Bragg peak position measurements were reproducible within ±30 μm and agreed with Geant4 simulations to better than 100 μm. The ionoacoustic signal pattern allowed for a detailed analysis of the Bragg peak and could be well reproduced by k-WAVE simulations. Conclusions: The authors have studied the ionoacoustic signal of the Bragg peak in experiments using a 20 MeV proton beam with its correspondingly localized energy deposition, demonstrating submillimeter position resolution and providing a deep insight in the correlation between the acoustic signal and Bragg peak shape. These results, together with earlier experiments and new simulations (including the results in this study) at higher energies, suggest ionoacoustics as a technique for range verification in particle therapy at locations, where the tumor can be localized by ultrasound