WorldWideScience

Sample records for measured parameter values

  1. Measuring the Michel parameter ξ''

    International Nuclear Information System (INIS)

    Knowles, P.; Deutsch, J.; Egger, J.; Fetscher, W.; Foroughi, F.; Govaerts, J.; Hadri, M.; Kirch, K.; Kistryn, S.; Lang, J.; Morelle, X.; Naviliat, O.; Ninane, A.; Prieels, R.; Severijns, N.; Simons, L.; Sromicki, J.; Vandormael, S.; Hove, P. van

    1999-01-01

    Unlike the majority of Michel parameters which are consistent with the Standard Model V-A interaction, the experimental value of ξ''(=0.65±0.36) [1] is poorly known. Our experiment will measure the longitudinal polarization, P L , of positrons emitted from the decay of polarized muons. The value of P L , equal to unity in the Standard Model, will decrease for high energy positrons emitted antiparallel to the muon spin if the combination of Michel parameters ξ''/ξξ' - 1 deviates from the Standard Model value of zero

  2. Statistical MOSFET Parameter Extraction with Parameter Selection for Minimal Point Measurement

    Directory of Open Access Journals (Sweden)

    Marga Alisjahbana

    2013-11-01

    Full Text Available A method to statistically extract MOSFET model parameters from a minimal number of transistor I(V characteristic curve measurements, taken during fabrication process monitoring. It includes a sensitivity analysis of the model, test/measurement point selection, and a parameter extraction experiment on the process data. The actual extraction is based on a linear error model, the sensitivity of the MOSFET model with respect to the parameters, and Newton-Raphson iterations. Simulated results showed good accuracy of parameter extraction and I(V curve fit for parameter deviations of up 20% from nominal values, including for a process shift of 10% from nominal.

  3. Measurement of the Acoustic Nonlinearity Parameter for Biological Media.

    Science.gov (United States)

    Cobb, Wesley Nelson

    In vitro measurements of the acoustic nonlinearity parameter are presented for several biological media. With these measurements it is possible to predict the distortion of a finite amplitude wave in biological tissues of current diagnostic and research interest. The measurement method is based on the finite amplitude distortion of a sine wave that is emmitted by a piston source. The growth of the second harmonic component of this wave is measured by a piston receiver which is coaxial with and has the same size as the source. The experimental measurements and theory are compared in order to determine the nonlinearity parameter. The density, sound speed, and attenuation for the medium are determined in order to make this comparison. The theory developed for this study accounts for the influence of both diffraction and attenuation on the experimental measurements. The effects of dispersion, tissue inhomogeneity and gas bubbles within the excised tissues are studied. To test the measurement method, experimental results are compared with established values for the nonlinearity parameter of distilled water, ethylene glycol and glycerol. The agreement between these values suggests that the measurement uncertainty is (+OR-) 5% for liquids and (+OR-) 10% for solid tissues. Measurements are presented for dog blood and bovine serum albumen as a function of concentration. The nonlinearity parameters for liver, kidney and spleen are reported for both human and canine tissues. The values for the fresh tissues displayed little variation (6.8 to 7.8). Measurements for fixed, normal and cirrhotic tissues indicated that the nonlinearity parameter does not depend strongly on pathology. However, the values for fixed tissues were somewhat higher than those of the fresh tissues.

  4. Measure-valued differentiation for finite products of measures : theory and applications

    NARCIS (Netherlands)

    Leahu, H.

    2008-01-01

    In this dissertation we perform a comprehensive analysis of measure-valued differentiation, in which weak differentiation of parameter-dependent probability measures plays a central role. We develop a theory of weak differentiation of measures and show that classical concepts such as differential

  5. Standardized uptake value in pediatric patients: an investigation to determine the optimum measurement parameter

    International Nuclear Information System (INIS)

    Yeung, H.W.; Squire, O.D.; Larson, S.M.; Erdi, Y.E.; Sanches, A.; Macapinlac, H.A.

    2002-01-01

    Although the standardized uptake value (SUV) is currently used in fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) imaging, concerns have been raised over its accuracy and clinical relevance. Dependence of the SUV on body weight has been observed in adults and this should be of concern in the pediatric population, since there are significant body changes during childhood. The aim of the present study was to compare SUV measurements based on body weight, body surface area and lean body mass in the pediatric population and to determine a more reliable parameter across all ages. Sixty-eight pediatric FDG-PET studies were evaluated. Age ranged from 2 to 17 years and weight from 11 to 77 kg. Regions of interest were drawn at the liver for physiologic comparison and at FDG-avid malignant lesions. SUV based on body weight (SUV bw ) varied across different weights, a phenomenon less evident when body surface area (SUV bsa ) normalization is applied. Lean body mass-based SUV (SUV lbm ) also showed a positive correlation with weight, which again was less evident when normalized to bsa (SUV bsa-lbm ). The measured liver SUV bw was 1.1±0.3, a much lower value than in our adult population (1.9±0.3). The liver SUV bsa was 7.3±1.3. The tumor sites had an SUV bw of 4.0±2.7 and an SUV bsa of 25.9±15.4 (65% of the patients had neuroblastoma). The bsa-based SUVs were more constant across the pediatric ages and were less dependent on body weight than the SUV bw . These results indicate that SUV calculated on the basis of body surface area is a more uniform parameter than SUV based on body weight in pediatric patients and is probably the most appropriate approach for the follow-up of these patients. (orig.)

  6. DAQ system for low density plasma parameters measurement

    International Nuclear Information System (INIS)

    Joshi, Rashmi S.; Gupta, Suryakant B.

    2015-01-01

    In various cases where low density plasmas (number density ranges from 1E4 to 1E6 cm -3 ) exist for example, basic plasma studies or LEO space environment measurement of plasma parameters becomes very critical. Conventional tip (cylindrical) Langmuir probes often result into unstable measurements in such lower density plasma. Due to larger surface area, a spherical Langmuir probe is used to measure such lower plasma densities. Applying a sweep voltage signal to the probe and measuring current values corresponding to these voltages gives V-I characteristics of plasma which can be plotted on a digital storage oscilloscope. This plot is analyzed for calculating various plasma parameters. The aim of this paper is to measure plasma parameters using a spherical Langmuir probe and indigenously developed DAQ system. DAQ system consists of Keithley source-meter and a host system connected by a GPIB interface. An online plasma parameter diagnostic system is developed for measuring plasma properties for non-thermal plasma in vacuum. An algorithm is developed using LabVIEW platform. V-I characteristics of plasma are plotted with respect to different filament current values and different locations of Langmuir probe with reference to plasma source. V-I characteristics is also plotted for forward and reverse voltage sweep generated programmatically from the source meter. (author)

  7. Activation method for measurement of neutron spectrum parameters

    International Nuclear Information System (INIS)

    Efimov, B.V.; Demidov, A.M.; Ionov, V.S.; Konjaev, S.I.; Marin, S.V.; Bryzgalov, V.I.

    2007-01-01

    Experimental researches of spectrum parameters of neutrons at nuclear installations RRC KI are submitted. The installations have different designs of the cores, reflector, parameters and types of fuel elements. Measurements were carried out with use of the technique developed in RRC KI for irradiation resonance detectors UKD. The arrangement of detectors in the cores ensured possibility of measurement of neutron spectra with distinguished values of parameters. The spectrum parameters which are introduced by parametrical representation of a neutrons spectrum in the form corresponding to formalism Westcott. On experimental data were determinate absolute values of density neutron flux (DNF) in thermal and epithermal area of a spectrum (F t , f epi ), empirical dependence of temperature of neutron gas (Tn) on parameter of a rigidity of a spectrum (z), density neutron flux in transitional energy area of the spectrum. Dependences of spectral indexes of nuclides (UDy/UX), included in UKD, from a rigidity z and-or temperatures of neutron gas Tn are obtained.B Tools of mathematical processing of results are used for activation data and estimation of parameters of a spectrum (F t , f epi , z, Tn, UDy/UX). In the paper are presented some results of researches of neutron spectrum parameters of the nuclear installations (Authors)

  8. Weak-value measurements can outperform conventional measurements

    International Nuclear Information System (INIS)

    Magaña-Loaiza, Omar S; Boyd, Robert W; Harris, Jérémie; Lundeen, Jeff S

    2017-01-01

    In this paper we provide a simple, straightforward example of a specific situation in which weak-value amplification (WVA) clearly outperforms conventional measurement in determining the angular orientation of an optical component. We also offer a perspective reconciling the views of some theorists, who claim WVA to be inherently sub-optimal for parameter estimation, with the perspective of the many experimentalists and theorists who have used the procedure to successfully access otherwise elusive phenomena. (invited comment)

  9. Neutron capture measurements and resonance parameters of dysprosium

    Energy Technology Data Exchange (ETDEWEB)

    Shin, S.G.; Kye, Y.U.; Namkung, W.; Cho, M.H. [Pohang University of Science and Technology, Division of Advanced Nuclear Engineering, Pohang, Gyeongbuk (Korea, Republic of); Kang, Y.R.; Lee, M.W. [Dongnam Inst. of Radiological and Medical Sciences, Research Center, Busan (Korea, Republic of); Kim, G.N. [Kyungpook National University, Department of Physics, Daegu (Korea, Republic of); Ro, T.I. [Dong-A University, Department of Physics, Busan (Korea, Republic of); Danon, Y.; Williams, D. [Rensselaer Polytechnic Institute, Department of Mechanical, Aerospace, and Nuclear Engineering, Troy, NY (United States); Leinweber, G.; Block, R.C.; Barry, D.P.; Rapp, M.J. [Naval Nuclear Laboratory, Knolls Atomic Power Laboratory, Schenectady, NY (United States)

    2017-10-15

    Neutron capture yields of dysprosium isotopes ({sup 161}Dy, {sup 162}Dy, {sup 163}Dy, and {sup 164}Dy) were measured using the time-of-flight method with a 16 segment sodium iodide multiplicity detector. The measurements were made at the 25m flight station at the Gaerttner LINAC Center at Rensselaer Polytechnic Institute. Resonance parameters were obtained using the multilevel R-matrix Bayesian code SAMMY. The neutron capture data for four enriched dysprosium isotopes and one natural dysprosium sample were sequentially fitted. New resonances not listed in ENDF/B-VII.1 were observed. There were 29 and 17 new resonances from {sup 161}Dy and {sup 163}Dy isotopes, respectively. Six resonances from {sup 161}Dy isotope, two resonances from {sup 163}Dy, and four resonances from {sup 164}Dy were not observed. The capture resonance integrals of each isotope were calculated with the resulting resonance parameters and those of ENDF/B-VII.1 in the energy region from 0.5 eV to 20 MeV and were compared to the capture resonance integrals with the resonance parameters from ENDF/B-VII.1. A resonance integral value of the natural dysprosium calculated with present resonance parameters was 1405 ± 3.5 barn. The value is ∝ 0.3% higher than that obtained with the ENDF/B-VII.1 parameters. The distributions of the present and ENDF/B-VII.1 neutron widths were compared to a Porter-Thomas distribution. Neutron strength functions for {sup 161}Dy and {sup 163}Dy were calculated with the present resonance parameters and both values were in between the values of ''Atlas of Neutron Resonances'' and ENDF/B-VII.1. The present radiation width distributions of {sup 161}Dy and {sup 163}Dy were fitted with the χ{sup 2} distribution by varying the degrees of freedom. (orig.)

  10. Value as a parameter to consider in operational strategies for CSP plants

    Science.gov (United States)

    de Meyer, Oelof; Dinter, Frank; Govender, Saneshan

    2017-06-01

    This paper introduced a value parameter to consider when analyzing operational strategies for CSP plants. The electric system in South Africa, used as case study, is severely constrained with an influx of renewables in the early phase of deployment. The energy demand curve for the system is analyzed showing the total wind and solar photovoltaic contributions for winter and summer. Due to the intermittent nature and meteorological operating conditions of wind and solar photovoltaic plants, the value of CSP plants within the electric system is introduced. Analyzing CSP plants based on the value parameter alone will remain only a philosophical view. Currently there is no quantifiable measure to translate the philosophical view or subjective value and it solely remains the position of the stakeholder. By introducing three other parameters, Cost, Plant and System to a holistic representation of the Operating Strategies of generation plants, the Value parameter can be translated into a quantifiable measure. Utilizing the country's current procurement program as case study, CSP operating under the various PPA within the Bid Windows are analyzed. The Value Cost Plant System diagram developed is used to quantify the value parameter. This paper concluded that no value is obtained from CSP plants operating under the Bid Window 1 & 2 Power Purchase Agreement. However, by recognizing the dispatchability potential of CSP plants in Bid Window 3 & 3.5, the value of CSP in the electric system can be quantified utilizing Value Added Relationship VCPS-diagram. Similarly ancillary services to the system were analyzed. One of the relationships that have not yet been explored within the industry is an interdependent relationship. It was emphasized that the cost and value structure is shared between the plant and system. Although this relationship is functional when the plant and system belongs to the same entity, additional value is achieved by marginalizing the cost structure. A

  11. Measurement of drill grinding parameters using laser sensor

    Science.gov (United States)

    Yanping, Peng; Kumehara, Hiroyuki; Wei, Zhang; Nomura, Takashi

    2005-12-01

    To measure the grinding parameters and geometry parameters accurately for a drill point is essential to its design and reconditioning. In recent years, a number of non-contact coordinate measuring apparatuses, using CCD camera or laser sensors, are developed. But, a lot work is to be done for further improvement. This paper reports another kind of laser coordinate meter. As an example of its application, the method for geometry inspection of the drill flank surface is detailed. Measured data from laser scanning on the flank surface around some points with several 2-dimensional curves are analyzed with mathematical procedure. If one of these curves turns to be a straight line, it must be the generatrix of the grinding cone. Thus, the grinding parameters are determined by a set of three generatrices. Then, the measurement method and data processing procedure are proposed. Its validity is assessed by measuring a sample with given parameters. The point geometry measured agrees well with the known values. In comparison with other methods in the published literature, it is simpler in computation and more accurate in results.

  12. Modeling phosphorus in the Lake Allatoona watershed using SWAT: I. Developing phosphorus parameter values.

    Science.gov (United States)

    Radcliffe, D E; Lin, Z; Risse, L M; Romeis, J J; Jackson, C R

    2009-01-01

    Lake Allatoona is a large reservoir north of Atlanta, GA, that drains an area of about 2870 km2 scheduled for a phosphorus (P) total maximum daily load (TMDL). The Soil and Water Assessment Tool (SWAT) model has been widely used for watershed-scale modeling of P, but there is little guidance on how to estimate P-related parameters, especially those related to in-stream P processes. In this paper, methods are demonstrated to individually estimate SWAT soil-related P parameters and to collectively estimate P parameters related to stream processes. Stream related parameters were obtained using the nutrient uptake length concept. In a manner similar to experiments conducted by stream ecologists, a small point source is simulated in a headwater sub-basin of the SWAT models, then the in-stream parameter values are adjusted collectively to get an uptake length of P similar to the values measured in the streams in the region. After adjusting the in-stream parameters, the P uptake length estimated in the simulations ranged from 53 to 149 km compared to uptake lengths measured by ecologists in the region of 11 to 85 km. Once the a priori P-related parameter set was developed, the SWAT models of main tributaries to Lake Allatoona were calibrated for daily transport. Models using SWAT P parameters derived from the methods in this paper outperformed models using default parameter values when predicting total P (TP) concentrations in streams during storm events and TP annual loads to Lake Allatoona.

  13. Influence of measurement errors and estimated parameters on combustion diagnosis

    International Nuclear Information System (INIS)

    Payri, F.; Molina, S.; Martin, J.; Armas, O.

    2006-01-01

    Thermodynamic diagnosis models are valuable tools for the study of Diesel combustion. Inputs required by such models comprise measured mean and instantaneous variables, together with suitable values for adjustable parameters used in different submodels. In the case of measured variables, one may estimate the uncertainty associated with measurement errors; however, the influence of errors in model parameter estimation may not be so easily established on an experimental basis. In this paper, a simulated pressure cycle has been used along with known input parameters, so that any uncertainty in the inputs is avoided. Then, the influence of errors in measured variables and geometric and heat transmission parameters on the results of a diagnosis combustion model for direct injection diesel engines have been studied. This procedure allowed to establish the relative importance of these parameters and to set limits to the maximal errors of the model, accounting for both the maximal expected errors in the input parameters and the sensitivity of the model to those errors

  14. Impacts of Different Types of Measurements on Estimating Unsaturatedflow Parameters

    Science.gov (United States)

    Shi, L.

    2015-12-01

    This study evaluates the value of different types of measurements for estimating soil hydraulic parameters. A numerical method based on ensemble Kalman filter (EnKF) is presented to solely or jointly assimilate point-scale soil water head data, point-scale soil water content data, surface soil water content data and groundwater level data. This study investigates the performance of EnKF under different types of data, the potential worth contained in these data, and the factors that may affect estimation accuracy. Results show that for all types of data, smaller measurements errors lead to faster convergence to the true values. Higher accuracy measurements are required to improve the parameter estimation if a large number of unknown parameters need to be identified simultaneously. The data worth implied by the surface soil water content data and groundwater level data is prone to corruption by a deviated initial guess. Surface soil moisture data are capable of identifying soil hydraulic parameters for the top layers, but exert less or no influence on deeper layers especially when estimating multiple parameters simultaneously. Groundwater level is one type of valuable information to infer the soil hydraulic parameters. However, based on the approach used in this study, the estimates from groundwater level data may suffer severe degradation if a large number of parameters must be identified. Combined use of two or more types of data is helpful to improve the parameter estimation.

  15. [Diagnostic value of quantitative pharmacokinetic parameters and relative quantitative pharmacokinetic parameters in breast lesions with dynamic contrast-enhanced MRI].

    Science.gov (United States)

    Sun, T T; Liu, W H; Zhang, Y Q; Li, L H; Wang, R; Ye, Y Y

    2017-08-01

    Objective: To explore the differential between the value of dynamic contrast-enhanced MRI quantitative pharmacokinetic parameters and relative pharmacokinetic quantitative parameters in breast lesions. Methods: Retrospective analysis of 255 patients(262 breast lesions) who was obtained by clinical palpation , ultrasound or full-field digital mammography , and then all lessions were pathologically confirmed in Zhongda Hospital, Southeast University from May 2012 to May 2016. A 3.0 T MRI scanner was used to obtain the quantitative MR pharmacokinetic parameters: volume transfer constant (K(trans)), exchange rate constant (k(ep))and extravascular extracellular volume fraction (V(e)). And measured the quantitative pharmacokinetic parameters of normal glands tissues which on the same side of the same level of the lesions; and then calculated the value of relative pharmacokinetic parameters: rK(rans)、rk(ep) and rV(e).To explore the diagnostic value of two pharmacokinetic parameters in differential diagnosis of benign and malignant breast lesions using receiver operating curves and model of logistic regression. Results: (1)There were significant differences between benign lesions and malignant lesions in K(trans) and k(ep) ( t =15.489, 15.022, respectively, P 0.05). The areas under the ROC curve(AUC)of K(trans), k(ep) and V(e) between malignant and benign lesions were 0.933, 0.948 and 0.387, the sensitivity of K(trans), k(ep) and V(e) were 77.1%, 85.0%, 51.0% , and the specificity of K(trans), k(ep) and V(e) were 96.3%, 93.6%, 60.8% for the differential diagnosis of breast lesions if taken the maximum Youden's index as cut-off. (2)There were significant differences between benign lesions and malignant lesions in rK(trans), rk(ep) and rV(e) ( t =14.177, 11.726, 2.477, respectively, P quantitative pharmacokinetic parameters and the prediction probability of relative quantitative pharmacokinetic parameters( Z =0.867, P =0.195). Conclusion: There was no significant

  16. A principle for the noninvasive measurement of steady-state heat transfer parameters in living tissues

    Directory of Open Access Journals (Sweden)

    S. Yu. Makarov

    2014-01-01

    Full Text Available Measuring the parameters of biological tissues (include in vivo is of great importance for medical diagnostics. For example, the value of the blood perfusion parameter is associated with the state of the blood microcirculation system and its functioning affects the state of the tissues of almost all organs. This work describes a previously proposed principle [1] in generalized terms. The principle is intended for noninvasive measuring the parameters of stationary heat transfer in biological tissues. The results of some experiments (natural and numeric are also presented in the research.For noninvasive measurement of thermophysical parameters a number of techniques have been developed using non-stationary thermal process in biological tissue [2][3]. But these techniques require the collecting a lot of data to represent the time-dependent thermal signal. In addition, subsequent processing with specialized algorithms is required for optimal selecting the parameters. The goal of this research is to develop an alternative approach using stationary thermal process for non-invasive measuring the parameters of stationary heat transfer in living tissues.A general principle can be formulated for the measurement methods based on this approach. Namely, the variations (changes of two physical values are measured in the experiment at the transition from one thermal stationary state to another. One of these two physical values unambiguously determines the stationary thermal field into the biological tissue under specified experimental conditions while the other one is unambiguously determined through the thermal field. Then, the parameters can be found from the numerical (or analytical functional dependencies linking the measured variations because the dependencies contain unknown parameters.The dependencies are expressed in terms of the formula:dqi = fi({pj},Ui dUi,Here dqi is a variation of a physical value q which is unambiguously determined from the

  17. Determination of electromagnetic absorption parameters by reflection measurements

    International Nuclear Information System (INIS)

    Vittitoe, C.N.

    1975-09-01

    The method described is for determining the electromagnetic absorption parameters of a material by measuring the optical reflection from a thick sample. With linearly polarized incident light (both perpendicular to and parallel to the plane of incidence), the ratio of the reflected intensities at three or more angles of incidence offers promise for determining the complex index of refraction of a material for a broad range of parameter values. The method may be applicable to molten materials, such as UO 2 , where high temperatures cause corrosion and containment difficulties. A method is given for extending the data to neighboring frequencies. Use of the method was successful for all portions of the complex index of refraction plane except for small values of the extinction coefficient

  18. Innovation of Methods for Measurement and Modelling of Twisted Pair Parameters

    Directory of Open Access Journals (Sweden)

    Lukas Cepa

    2011-01-01

    Full Text Available The goal of this paper is to optimize a measurement methodology for the most accurate broadband modelling of characteristic impedance and other parameters for twisted pairs. Measured values and theirs comparison is presented in this article. Automated measurement facility was implemented at the Department of telecommunication of Faculty of electrical engineering of Czech technical university in Prague. Measurement facility contains RF switches allowing measurements up to 300 MHz or 1GHz. Measured twisted pair’s parameters can be obtained by measurement but for purposes of fundamental characteristics modelling is useful to define functions that model the properties of the twisted pair. Its primary and secondary parameters depend mostly on the frequency. For twisted pair deployment, we are interested in a frequency band range from 1 MHz to 100 MHz.

  19. Uncertainty analyses of the calibrated parameter values of a water quality model

    Science.gov (United States)

    Rode, M.; Suhr, U.; Lindenschmidt, K.-E.

    2003-04-01

    For river basin management water quality models are increasingly used for the analysis and evaluation of different management measures. However substantial uncertainties exist in parameter values depending on the available calibration data. In this paper an uncertainty analysis for a water quality model is presented, which considers the impact of available model calibration data and the variance of input variables. The investigation was conducted based on four extensive flowtime related longitudinal surveys in the River Elbe in the years 1996 to 1999 with varying discharges and seasonal conditions. For the model calculations the deterministic model QSIM of the BfG (Germany) was used. QSIM is a one dimensional water quality model and uses standard algorithms for hydrodynamics and phytoplankton dynamics in running waters, e.g. Michaelis Menten/Monod kinetics, which are used in a wide range of models. The multi-objective calibration of the model was carried out with the nonlinear parameter estimator PEST. The results show that for individual flow time related measuring surveys very good agreements between model calculation and measured values can be obtained. If these parameters are applied to deviating boundary conditions, substantial errors in model calculation can occur. These uncertainties can be decreased with an increased calibration database. More reliable model parameters can be identified, which supply reasonable results for broader boundary conditions. The extension of the application of the parameter set on a wider range of water quality conditions leads to a slight reduction of the model precision for the specific water quality situation. Moreover the investigations show that highly variable water quality variables like the algal biomass always allow a smaller forecast accuracy than variables with lower coefficients of variation like e.g. nitrate.

  20. Analysis of Camera Parameters Value in Various Object Distances Calibration

    International Nuclear Information System (INIS)

    Yusoff, Ahmad Razali; Ariff, Mohd Farid Mohd; Idris, Khairulnizam M; Majid, Zulkepli; Setan, Halim; Chong, Albert K

    2014-01-01

    In photogrammetric applications, good camera parameters are needed for mapping purpose such as an Unmanned Aerial Vehicle (UAV) that encompassed with non-metric camera devices. Simple camera calibration was being a common application in many laboratory works in order to get the camera parameter's value. In aerial mapping, interior camera parameters' value from close-range camera calibration is used to correct the image error. However, the causes and effects of the calibration steps used to get accurate mapping need to be analyze. Therefore, this research aims to contribute an analysis of camera parameters from portable calibration frame of 1.5 × 1 meter dimension size. Object distances of two, three, four, five, and six meters are the research focus. Results are analyzed to find out the changes in image and camera parameters' value. Hence, camera calibration parameter's of a camera is consider different depend on type of calibration parameters and object distances

  1. Resolving model parameter values from carbon and nitrogen stock measurements in a wide range of tropical mature forests using nonlinear inversion and regression trees

    Science.gov (United States)

    Shuguang Liua; Pamela Anderson; Guoyi Zhoud; Boone Kauffman; Flint Hughes; David Schimel; Vicente Watson; Joseph. Tosi

    2008-01-01

    Objectively assessing the performance of a model and deriving model parameter values from observations are critical and challenging in landscape to regional modeling. In this paper, we applied a nonlinear inversion technique to calibrate the ecosystem model CENTURY against carbon (C) and nitrogen (N) stock measurements collected from 39 mature tropical forest sites in...

  2. Measurement of some biophysical parameters in skin lesions of leprosy

    Directory of Open Access Journals (Sweden)

    A B Gupta

    1990-01-01

    Full Text Available Transepidermal water loss (TEWL, high frequency electrical conductance (HFC and the hydration state index (HSI were measured in sldn lesions of 30 paucibacillary leprosy patients and compared with the contralateral uninvolved skin. While the TEWL, HFC and HSI all showed lower values in the lesion site, as compared to the contralateral skin sites, the differences between the two sets of values significant in HFC and. HSI only at 2% and 1% level respectively. A significant positive correlation (r = 0.69 was found to eidst between these two parameters. The parameters correlate well with the known reduced sweating in skin lesions of TT and BT leprosy and may therefore be considered as good objective parameters to confirm hypohydrosis in suspected skin lesions ofleprosy.

  3. Reflow Process Parameters Analysis and Reliability Prediction Considering Multiple Characteristic Values

    Directory of Open Access Journals (Sweden)

    Guo Yu

    2016-01-01

    Full Text Available As a major step surface mount technology, reflow process is the key factor affecting the quality of the final product. The setting parameters and characteristic value of temperature curve shows a nonlinear relationship. So parameter impacts on characteristic values are analyzed and the parameters adjustment process based on orthogonal experiment is proposed in the paper. First, setting parameters are determined and the orthogonal test is designed according to production conditions. Then each characteristic value for temperature profile is calculated. Further, multi-index orthogonal experiment is analyzed for acquiring the setting parameters which impacts the PCBA product quality greater. Finally, reliability prediction is carried out considering the main influencing parameters for providing a theoretical basis of parameters adjustment and product quality evaluation in engineering process.

  4. Variances as order parameter and complexity measure for random Boolean networks

    International Nuclear Information System (INIS)

    Luque, Bartolo; Ballesteros, Fernando J; Fernandez, Manuel

    2005-01-01

    Several order parameters have been considered to predict and characterize the transition between ordered and disordered phases in random Boolean networks, such as the Hamming distance between replicas or the stable core, which have been successfully used. In this work, we propose a natural and clear new order parameter: the temporal variance. We compute its value analytically and compare it with the results of numerical experiments. Finally, we propose a complexity measure based on the compromise between temporal and spatial variances. This new order parameter and its related complexity measure can be easily applied to other complex systems

  5. Variances as order parameter and complexity measure for random Boolean networks

    Energy Technology Data Exchange (ETDEWEB)

    Luque, Bartolo [Departamento de Matematica Aplicada y EstadIstica, Escuela Superior de Ingenieros Aeronauticos, Universidad Politecnica de Madrid, Plaza Cardenal Cisneros 3, Madrid 28040 (Spain); Ballesteros, Fernando J [Observatori Astronomic, Universitat de Valencia, Ed. Instituts d' Investigacio, Pol. La Coma s/n, E-46980 Paterna, Valencia (Spain); Fernandez, Manuel [Departamento de Matematica Aplicada y EstadIstica, Escuela Superior de Ingenieros Aeronauticos, Universidad Politecnica de Madrid, Plaza Cardenal Cisneros 3, Madrid 28040 (Spain)

    2005-02-04

    Several order parameters have been considered to predict and characterize the transition between ordered and disordered phases in random Boolean networks, such as the Hamming distance between replicas or the stable core, which have been successfully used. In this work, we propose a natural and clear new order parameter: the temporal variance. We compute its value analytically and compare it with the results of numerical experiments. Finally, we propose a complexity measure based on the compromise between temporal and spatial variances. This new order parameter and its related complexity measure can be easily applied to other complex systems.

  6. Comparation of Some Values of Measured Parameteres between Old and New X-Ray Machines

    International Nuclear Information System (INIS)

    Kocic, B.; Marinkovic, J.; Praskalo, J.

    2013-01-01

    Checking the change of values of parameters like specific value of kerma, repeatability of expositions, linearity of exposition, stability of high voltage, time of exposition and HVL of X-ray machines that are in use in medical centres of Republic of Serbia give us an idea of comparing those values for two groups of X-ray machines. One is in use since 70's in last century and is still in use, and the other group is quite new, and is controlled for last 5 years. Checking the results of controlled parameters within those two groups of X-ray machines we can compare stability and quality of old and new machines, and the influence of 'aging' of machines to the quality and stability of measured parameters. Some of conclusions are that old machines are showing better stability and repeatability of values of measured parameters during the 'aging' than new machines.(author)

  7. Radon decay product in-door behaviour - parameter, measurement method, and model review

    International Nuclear Information System (INIS)

    Scofield, P.

    1988-01-01

    This report reviews parameters used to characterize indoor radon daughter behavior and concentrations. Certain parameters that affect indoor radon daughter concentrations are described and the values obtained experimentally or theoretically are summarized. Radon daughter measurement methods are reviewed, such as, PAEC, unattached daughters, particle size distributions, and plateout measurement methods. In addition, certain radon pressure driven/diffusion models and indoor radon daughter models are briefly described. (orig.)

  8. Measurement of the geometric parameters of power contact wire based on binocular stereovision

    Science.gov (United States)

    Pan, Xue-Tao; Zhang, Ya-feng; Meng, Fei

    2010-10-01

    In the electrified railway power supply system, electric locomotive obtains power from the catenary's wire through the pantograph. Under the action of the pantograph, combined with various factors such as vibration, touch current, relative sliding speed, load, etc, the contact wire will produce mechanical wear and electrical wear. Thus, in electrified railway construction and daily operations, the geometric parameters such as line height, pull value, the width of wear surface must be under real-timely and non-contact detection. On the one hand, the safe operation of electric railways will be guaranteed; on the other hand, the wire endurance will be extended, and operating costs reduced. Based on the characteristics of the worn wires' image signal, the binocular stereo vision technology was applied for measurement of contact wire geometry parameters, a mathematical model of measurement of geometric parameters was derived, and the boundaries of the wound wire abrasion-point value were extracted by means of sub-pixel edge detection method based on the LOG operator with the least-squares fitting, thus measurements of the wire geometry parameters were realized. Principles were demonstrated through simulation experiments, and the experimental results show that the detection methods presented in this paper for measuring the accuracy, efficiency and convenience, etc. are close to or superior to the traditional measurements, which has laid a good foundation for the measurement system of geometric parameters for the contact wire of the development of binocular vision.

  9. Analysis of the value recommended by the NCRP 151 and its relationship with Brazilian parameters

    International Nuclear Information System (INIS)

    Groppo, Daniela P.; Martins, Homero L.

    2009-01-01

    The methodology proposed by the National Council on Radiation Protection 151 (NCRP 151), relates technical information necessary to structural shielding design and evaluation for megavoltage X- and gamma- ray radiotherapy facilities. However, many parameters used to calculate the shield are based on estimates, and may not be adequate to the Brazilian reality. Thus, the central idea of this study is to obtain parameters and is to outline a profile closer to the treatments carried out in facilities in Brazil, through a data collection routine of the Department of Radiotherapy Service of the Real e Benemerita Associacao Portuguesa de Beneficencia, in particular the cobalt therapy Theratron 780 (Atomic Energy of Canada Ltd.) and the linear accelerator Varian Clinac 2100C for measurement of workload, use factor, number of patients, fields, dose and anatomic region treated. So, the work did not draw definite values of the parameters, but indicative values were obtained which showed the importance to carry out more detailed studies of the recommended values. (author)

  10. The influence of the maximal value and peak enhancement value of arterial and venous enhancement curve on CT perfusion parameters and signal-to-noise ratio

    International Nuclear Information System (INIS)

    Ju Haiyue; Gao Sijia; Xu Ke; Wang Qiang

    2007-01-01

    Objective: To explore the influence of the maximal value and peak enhancement value of arterial and venous enhancement curve on CT perfusion parameters and signal-to-noise ratio (SNR). Methods: Seventeen patients underwent brain CT perfusion scanning. All row data were analyzed with perfusion software for 6 times, and get different arterial and venous enhancement curves for each patient. The maximal values and peak enhancement values of each arterial and venous enhancement curves, as well as mean perfusion parameters including cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), permeability surface area product (PS), and their standard deviations (SD) in homolateral white and gray matter were measured and recorded. SNR was calculated by dividing the mean perfusion parameter value by its SD. Pearson correlation analysis and two-tailed paired Student t test were used for statistics. Results: The maximal values and peak enhancement values of arterial and venous curves were correlated with mean SNR CBF , SNR CBV and SNR MTT in both white matter and gray matters (r value range: 0.332-0.922, P PS in white matter(r=0.256, P PS (in both white matter and gray matters) and arterial peak enhancement values, the maximal values and venous peak enhancement values, or between SNR PS (in gray matter) and the maximal values of venous curve(r value range: -0.058-0.210, P>0.05). (2) Mean CBF, CBV and PS values in the group with low venous peak enhancement values were significantly different from the group with high venous peak enhancement values in both white and gray matters (t value range: 3.830-5.337, P 0.05). Conclusions: The mean perfusion parameters and SNR are influenced by the maximal values and peak enhancement values of the arterial and venous curves. Peak enhancement of arterial and venous curves should be adjusted to higher level to make parameter values more reliable and increase the SNR. (authors)

  11. Ultrasonic measurements and other allied parameters of yttrium soaps in mixed organic solvents

    International Nuclear Information System (INIS)

    Mehrotra, K.N.; Tandon, K.

    1990-01-01

    The ultrasonic measurements of yttrium soaps were made in a mixture of 70 % benzene and 30 % dimethylsulfoxide (ν/ν) to determine the critical micelle concentration, soap-solvent interaction and various acoustic and thermodynamic parameters. The values of the CMC decrease with increasing chainlength of fatty acid constituent of the soap molecule and are in agreement with the values obtained from other micellar properties. The various acoustic parameters (intermolecular freelength, adiabatic compressibility, apparent molar compressibility, specific acoustic impedance, apparent molar volume, molar sound velocity, solvation number, available volume and relative association) for yttrium soaps (myristate, palmitate, stearate and oleate) have been evaluated by ultrasonic velocity measurements. (Authors)

  12. Measurement of use value and non-use value of environmental quality consistent with general equilibrium approach

    OpenAIRE

    Naoki Sakamoto; Kazunori Nakajima

    2014-01-01

    This paper proposes the consistent method with general equilibrium models to measure use value and non-use value of large-scale change in environmental quality. First, we develop a general equilibrium model that parameters of the utility function with environmental quality as a dependent variable can be estimated on the basis of the travel cost method and the contingent variation method. Second, we examine to identify the general equilibrium impact of environmental quality by a comparative st...

  13. Measurement of half-value layer in mammography

    CERN Document Server

    Yagi, H; Saruwatari, R; Doi, N; Yamane, E

    2003-01-01

    The half-value layer (HVL) of an X-ray beam for film-screen mammography is considered an important parameter for image quality and patient dose. Thus, HVL must be measured in accordance with The Manual of Accuracy for Mammography printed by the Japanese Society of Radiological Technology. The manual prescribes exactly the geometry of measurement, chamber position of measurement in the field, selection of chamber, and so on. However, the measurement of HVL is difficult in the actual clinical setting. This study examined the results of failure to perform the measurement of HVL in accordance with the manual for measuring HVL in the clinical setting. The investigation indicated that serious problems do not arise when measuring HVL for routine quality control even if the chamber in the field is not always set according to the manual and if a chamber for radiotherapy or diagnosis is used that is not recommended for soft X-ray by the manual. (author)

  14. Parameter values for the estimation of radionuclide transfer to major food crops in Korea

    International Nuclear Information System (INIS)

    Choi, Yong-Ho; Lim, Kwang-Muk; Jun, In; Keum, Dong-Kwon; Lee, Chang-Woo

    2008-01-01

    This paper summarizes the results of the radiotracer experiments and field studies performed in Korea for the past 20 years to obtain parameter values for estimating the environmental transfer of radionuclides to food crops. With regards to direct plant contamination, the interception fractions, weathering half-lives and translocation factors of Cs, Sr, Mn, Co and Ru were measured for depositions at different growth stages of selected food crops. In order to investigate an indirect contamination pathway, the soil-to-plant transfer factors (TF m , dimensionless) of Cs, Sr, Mn, Co and/or Zn were measured for rice, Chinese cabbage, radish, soybean, barley, lettuce and so on in one or more soils. In addition, the transfer factors (TF a , m 2 kg -1 ) based on a deposition density were also measured following depositions at different times during the growth periods of several food crops. Particularly for rice and Chinese cabbage, tritium experiments were also carried out for the TF a . The obtained parameter values varied considerably with the soils, crops, radionuclides and deposition times. These data would be applicable to both normal and acute releases not only in Korea but also in many other countries. (author)

  15. Measurements for kinetic parameters estimation in the RA-0 research reactor

    International Nuclear Information System (INIS)

    Gomez, A; Bellino, P A

    2012-01-01

    In the present work, measurements based on the neutron noise technique and the inverse kinetic method were performed to estimate the different kinetic parameters of the reactor in its critical state. By means of the neutron noise technique, we obtained the current calibration factor of the ionization chamber M6 belonging to the power range channels of the reactor instrumentation. The maximum current allowed compatible with the maximum power authorized by the operation license was also obtained. Using the neutron noise technique, the reduced mean reproduction time (Λ*) was estimated. This parameter plays a fundamental role in the deterministic analysis of criticality accidents. Comparison with previous values justified performing new measurements to study systematic trends in the value of Λ*. Using the inverse kinetics method, the reactivity worth of the control rods was estimated, confirming the existence of spatial effects and trends previously observed (author)

  16. Express method for contactless measurement of parameters of thermoelectric materials

    Directory of Open Access Journals (Sweden)

    Ashcheulov A. A.

    2015-08-01

    Full Text Available The paper presents an original method for contactless express measurement of parameters of thermoelectric materials. The presence of a combination of AC and DC magnetic fields in the gap of the oscillating circuit, where the monitored sample of the thermoelectric material is located, leads — due to Ampere force — to delamination of geometric regions of the occurrence of half-cycles of Foucault current. This in turn causes the appearance of additional heat losses in the oscillating circuit caused by Peltier effect. Computer modeling of these processes with the use of the software package ComsolFenlab 3.3 allowed determining the nature and magnitude of the electric currents in oscillating circuit, the range of operating frequencies, and the ratio of amplitudes of the variable and fixed components of the magnetic field. These components eventually cause a certain temperature difference along the controlled sample, which difference is proportional to the thermoelectric figure of merit Z of the material. The basic expressions are obtained for determining the value of the Seebeck coefficient a, thermal conductivity ?, electrical conductivity ? and thermoelectric figure of merit Z. A description is given to the design of the device for contactless express measurement of parameters of thermoelectric materials based on Bi—Te—Se—Sb solid solutions. Its distinctive feature is the ability to determine the symmetric and asymmetric components of the electric conductivity of the material values. The actual error in parameter measurement in this case is 2%.

  17. MR flow velocity measurement using 2D phase contrast, assessment of imaging parameters

    International Nuclear Information System (INIS)

    Akata, Soichi; Fukushima, Akihiro; Abe, Kimihiko; Darkanzanli, A.; Gmitro, A.F.; Unger, E.C.; Capp, M.P.

    1999-01-01

    The two-dimensional (2D) phase contrast technique using balanced gradient pulses is utilized to measure flow velocities of cerebrospinal fluid and blood. Various imaging parameters affect the accuracy of flow velocity measurements to varying degrees. Assessment of the errors introduced by changing the imaging parameters are presented and discussed in this paper. A constant flow phantom consisting of a pump, a polyethylene tube and a flow meter was assembled. A clinical 1.5 Tesla MR imager was used to perform flow velocity measurements. The phase contrast technique was used to estimate the flow velocity of saline through the phantom. The effects of changes in matrix size, flip angle, flow compensation, and velocity encoding (VENC) value were tested in the pulse sequence. Gd-DTPA doped saline was used to study the effect of changing T1 on the accuracy of flow velocity measurement. Matrix size (within practical values), flip angle, and flow compensation had minimum impact on flow velocity measurements. T1 of the solution also had no effect on the accuracy of measuring the flow velocity. On the other hand, it was concluded that errors as high as 20% can be expected in the flow velocity measurements if the VENC value is not properly chosen. (author)

  18. MR flow velocity measurement using 2D phase contrast, assessment of imaging parameters

    Energy Technology Data Exchange (ETDEWEB)

    Akata, Soichi; Fukushima, Akihiro; Abe, Kimihiko [Tokyo Medical Coll. (Japan); Darkanzanli, A.; Gmitro, A.F.; Unger, E.C.; Capp, M.P.

    1999-11-01

    The two-dimensional (2D) phase contrast technique using balanced gradient pulses is utilized to measure flow velocities of cerebrospinal fluid and blood. Various imaging parameters affect the accuracy of flow velocity measurements to varying degrees. Assessment of the errors introduced by changing the imaging parameters are presented and discussed in this paper. A constant flow phantom consisting of a pump, a polyethylene tube and a flow meter was assembled. A clinical 1.5 Tesla MR imager was used to perform flow velocity measurements. The phase contrast technique was used to estimate the flow velocity of saline through the phantom. The effects of changes in matrix size, flip angle, flow compensation, and velocity encoding (VENC) value were tested in the pulse sequence. Gd-DTPA doped saline was used to study the effect of changing T1 on the accuracy of flow velocity measurement. Matrix size (within practical values), flip angle, and flow compensation had minimum impact on flow velocity measurements. T1 of the solution also had no effect on the accuracy of measuring the flow velocity. On the other hand, it was concluded that errors as high as 20% can be expected in the flow velocity measurements if the VENC value is not properly chosen. (author)

  19. Weak-value amplification and optimal parameter estimation in the presence of correlated noise

    Science.gov (United States)

    Sinclair, Josiah; Hallaji, Matin; Steinberg, Aephraim M.; Tollaksen, Jeff; Jordan, Andrew N.

    2017-11-01

    We analytically and numerically investigate the performance of weak-value amplification (WVA) and related parameter estimation methods in the presence of temporally correlated noise. WVA is a special instance of a general measurement strategy that involves sorting data into separate subsets based on the outcome of a second "partitioning" measurement. Using a simplified correlated noise model that can be analyzed exactly together with optimal statistical estimators, we compare WVA to a conventional measurement method. We find that WVA indeed yields a much lower variance of the parameter of interest than the conventional technique does, optimized in the absence of any partitioning measurements. In contrast, a statistically optimal analysis that employs partitioning measurements, incorporating all partitioned results and their known correlations, is found to yield an improvement—typically slight—over the noise reduction achieved by WVA. This result occurs because the simple WVA technique is not tailored to any specific noise environment and therefore does not make use of correlations between the different partitions. We also compare WVA to traditional background subtraction, a familiar technique where measurement outcomes are partitioned to eliminate unknown offsets or errors in calibration. Surprisingly, for the cases we consider, background subtraction turns out to be a special case of the optimal partitioning approach, possessing a similar typically slight advantage over WVA. These results give deeper insight into the role of partitioning measurements (with or without postselection) in enhancing measurement precision, which some have found puzzling. They also resolve previously made conflicting claims about the usefulness of weak-value amplification to precision measurement in the presence of correlated noise. We finish by presenting numerical results to model a more realistic laboratory situation of time-decaying correlations, showing that our conclusions hold

  20. Effect of Scanning and Reconstruction Parameters on Three Dimensional Volume and CT Value Measurement of Pulmonary Nodules: A Phantom Study

    Directory of Open Access Journals (Sweden)

    Datong SU

    2017-08-01

    Full Text Available Background and objective The computed tomography (CT follow-up of indeterminate pulmonary nodules aiming to evaluate the change of the volume and CT value is the common strategy in clinic. The CT dose needs to considered on serious CT scans in addition to the measurement accuracy. The purpose of this study is to quantify the precision of pulmonary nodule volumetric measurement and CT value measurement with various tube currents and reconstruction algorithms in a phantom study with dual-energy CT. Methods A chest phantom containing 9 artificial spherical solid nodules with known diameter (D=2.5 mm, 5 mm, 10 mm and density (-100 HU, 60 HU and 100 HU was scanned using a 64-row detector CT canner at 120 Kilovolt & various currents (10 mA, 20 mA, 50 mA, 80 mA,100 mA, 150 mA and 350 mA. Raw data were reconstructed with filtered back projection and three levels of adaptive statistical iterative reconstruction algorithm (FBP, ASIR; 30%, 50% and 80%. Automatic volumetric measurements were performed using commercially available software. The relative volume error (RVE and the absolute attenuation error (AAE between the software measures and the reference-standard were calculated. Analyses of the variance were performed to evaluate the effect of reconstruction methods, different scan parameters, nodule size and attenuation on the RPE. Results The software substantially overestimated the very small (D=2.5 mm nodule's volume [mean RVE: (100.8%±28%] and underestimated it attenuation [mean AAE: (-756±80 HU]. The mean RVEs of nodule with diameter as 5 mm and 10 mm were small [(-0.9%±1.1% vs (0.9%±1.4%], however, the mean AAEs [(-243±26 HU vs (-129±7 HU] were large. The ANOVA analysis for repeated measurements showed that different tube current and reconstruction algorithm had no significant effect on the volumetric measurements for nodules with diameter of 5 mm and 10 mm (F=5.60, P=0.10 vs F=11.13, P=0.08, but significant effects on the measurement of CT

  1. Determination of temperature dependant viscosity values of lubricants via simultaneous measurements of refractive index

    International Nuclear Information System (INIS)

    Yaltkaya, S.

    2005-01-01

    Viscosity is one of the most important parameter in rheological and tribological properties of fluids. The objective of this study is to obtain the viscosity values from the simultaneous refractive-index measurements of lubricants, simply by dipping the fiber-optic probe into the oil to be measured. Due to the fact that these parameters are temperature dependent, within the interval under consideration, oil heated up steadily while measuring the viscosity and refractive index at the same time. The refractive index sensor, the digital viscometer and the thermometer were connected to a PC via an analog to digital converter and the values were acquired at the same time. The fiber optic refractive index sensor has been designed in our laboratory. By utilising Fresnel's fundamental reflection law, the intensity of reflected light from boundary surface (optic fiber core-motor oil) was measured at 660 nm wavelength and then refractive index of the oil was calculated. The derived refractive index values were converted viscosity values that acquired by using the calibration equation. The viscometer, used during the study, was the rotational Brookfield type

  2. Sensitivity of NTCP parameter values against a change of dose calculation algorithm

    International Nuclear Information System (INIS)

    Brink, Carsten; Berg, Martin; Nielsen, Morten

    2007-01-01

    Optimization of radiation treatment planning requires estimations of the normal tissue complication probability (NTCP). A number of models exist that estimate NTCP from a calculated dose distribution. Since different dose calculation algorithms use different approximations the dose distributions predicted for a given treatment will in general depend on the algorithm. The purpose of this work is to test whether the optimal NTCP parameter values change significantly when the dose calculation algorithm is changed. The treatment plans for 17 breast cancer patients have retrospectively been recalculated with a collapsed cone algorithm (CC) to compare the NTCP estimates for radiation pneumonitis with those obtained from the clinically used pencil beam algorithm (PB). For the PB calculations the NTCP parameters were taken from previously published values for three different models. For the CC calculations the parameters were fitted to give the same NTCP as for the PB calculations. This paper demonstrates that significant shifts of the NTCP parameter values are observed for three models, comparable in magnitude to the uncertainties of the published parameter values. Thus, it is important to quote the applied dose calculation algorithm when reporting estimates of NTCP parameters in order to ensure correct use of the models

  3. Improved performance of photosynthetic light response equations with unified parameters for rice leaves with different SPAD values

    International Nuclear Information System (INIS)

    Xu, J.; Peng, S.; Kong, W.

    2015-01-01

    The rectangular hyperbola (RH), Mitscherlich (M) and YE equation were applied to describe the photosynthetic light response (PLR) curves measured from rice leaves with different SPAD values, to reveal the relationship between SPAD values and parameters in different equations, and to establish the modified PLR equations. The parameters in PLR equations are largely varied. SPAD value, as an indicator of leaf N contents, was highly correlated to the parameter of Pnmax in RH, M and YE equations. Incorporating the factor SPAD into PLR equations, the modified equations (MRH, MM, and MYE) were established which were feasible to describing the PLR curves for leaves with different SPAD values using the identical parameters for the ten PLR curves as a whole, and perform much better than the general PLR equations (GRH, GM, and GYE). It indicated that incorporating easy available indicators of leaf physiological and morphological traits in the PLR equations, such as SPAD as an indicator of leaf N or Chlorophyll contents, is an easy way to overcome the shortcoming of parameters variation in PLR equations between individuals of the same specie growing in different environments. Further validation should be done for different crops with both SPAD and other possible factors. (author)

  4. The estimation of parameter compaction values for pavement subgrade stabilized with lime

    Science.gov (United States)

    Lubis, A. S.; Muis, Z. A.; Simbolon, C. A.

    2018-02-01

    The type of soil material, field control, maintenance and availability of funds are several factors that must be considered in compaction of the pavement subgrade. In determining the compaction parameters in laboratory desperately requires considerable materials, time and funds, and reliable laboratory operators. If the result of soil classification values can be used to estimate the compaction parameters of a subgrade material, so it would save time, energy, materials and cost on the execution of this work. This is also a clarification (cross check) of the work that has been done by technicians in the laboratory. The study aims to estimate the compaction parameter values ie. maximum dry unit weight (γdmax) and optimum water content (Wopt) of the soil subgrade that stabilized with lime. The tests that conducted in the laboratory of soil mechanics were to determine the index properties (Fines and Liquid Limit/LL) and Standard Compaction Test. Soil samples that have Plasticity Index (PI) > 10% were made with additional 3% lime for 30 samples. By using the Goswami equation, the compaction parameter values can be estimated by equation γd max # = -0,1686 Log G + 1,8434 and Wopt # = 2,9178 log G + 17,086. From the validation calculation, there was a significant positive correlation between the compaction parameter values laboratory and the compaction parameter values estimated, with a 95% confidence interval as a strong relationship.

  5. Models for setting ATM parameter values

    DEFF Research Database (Denmark)

    Blaabjerg, Søren; Gravey, A.; Romæuf, L.

    1996-01-01

    essential to set traffic characteristic values that are relevant to the considered cell stream, and that ensure that the amount of non-conforming traffic is small. Using a queueing model representation for the GCRA formalism, several methods are available for choosing the traffic characteristics. This paper......In ATM networks, a user should negotiate at connection set-up a traffic contract which includes traffic characteristics and requested QoS. The traffic characteristics currently considered are the Peak Cell Rate, the Sustainable Cell Rate, the Intrinsic Burst Tolerance and the Cell Delay Variation...... (CDV) tolerance(s). The values taken by these traffic parameters characterize the so-called ''Worst Case Traffic'' that is used by CAC procedures for accepting a new connection and allocating resources to it. Conformance to the negotiated traffic characteristics is defined, at the ingress User...

  6. Reconstructing weak values without weak measurements

    International Nuclear Information System (INIS)

    Johansen, Lars M.

    2007-01-01

    I propose a scheme for reconstructing the weak value of an observable without the need for weak measurements. The post-selection in weak measurements is replaced by an initial projector measurement. The observable can be measured using any form of interaction, including projective measurements. The reconstruction is effected by measuring the change in the expectation value of the observable due to the projector measurement. The weak value may take nonclassical values if the projector measurement disturbs the expectation value of the observable

  7. Quantitative photoacoustic integrating sphere (QPAIS platform for absorption coefficient and Grüneisen parameter measurements: Demonstration with human blood

    Directory of Open Access Journals (Sweden)

    Yolanda Villanueva-Palero

    2017-06-01

    Full Text Available Quantitative photoacoustic imaging in biomedicine relies on accurate measurements of relevant material properties of target absorbers. Here, we present a method for simultaneous measurements of the absorption coefficient and Grüneisen parameter of small volume of liquid scattering and absorbing media using a coupled-integrating sphere system which we refer to as quantitative photoacoustic integrating sphere (QPAIS platform. The derived equations do not require absolute magnitudes of optical energy and pressure values, only calibration of the setup using aqueous ink dilutions is necessary. As a demonstration, measurements with blood samples from various human donors are done at room and body temperatures using an incubator. Measured absorption coefficient values are consistent with known oxygen saturation dependence of blood absorption at 750 nm, whereas measured Grüneisen parameter values indicate variability among five different donors. An increasing Grüneisen parameter value with both hematocrit and temperature is observed. These observations are consistent with those reported in literature.

  8. Improved noninvasive prediction of liver fibrosis by liver stiffness measurement in patients with nonalcoholic fatty liver disease accounting for controlled attenuation parameter values.

    Science.gov (United States)

    Petta, Salvatore; Wong, Vincent Wai-Sun; Cammà, Calogero; Hiriart, Jean-Baptiste; Wong, Grace Lai-Hung; Marra, Fabio; Vergniol, Julien; Chan, Anthony Wing-Hung; Di Marco, Vito; Merrouche, Wassil; Chan, Henry Lik-Yuen; Barbara, Marco; Le-Bail, Brigitte; Arena, Umberto; Craxì, Antonio; de Ledinghen, Victor

    2017-04-01

    Liver stiffness measurement (LSM) frequently overestimates the severity of liver fibrosis in nonalcoholic fatty liver disease (NAFLD). Controlled attenuation parameter (CAP) is a new parameter provided by the same machine used for LSM and associated with both steatosis and body mass index, the two factors mostly affecting LSM performance in NAFLD. We aimed to determine whether prediction of liver fibrosis by LSM in NAFLD patients is affected by CAP values. Patients (n = 324) were assessed by clinical and histological (Kleiner score) features. LSM and CAP were performed using the M probe. CAP values were grouped by tertiles (lower 132-298, middle 299-338, higher 339-400 dB/m). Among patients with F0-F2 fibrosis, mean LSM values, expressed in kilopascals, increased according to CAP tertiles (6.8 versus 8.6 versus 9.4, P = 0.001), and along this line the area under the curve of LSM for the diagnosis of F3-F4 fibrosis was progressively reduced from lower to middle and further to higher CAP tertiles (0.915, 0.848-0.982; 0.830, 0.753-0.908; 0.806, 0.723-0.890). As a consequence, in subjects with F0-F2 fibrosis, the rates of false-positive LSM results for F3-F4 fibrosis increased according to CAP tertiles (7.2% in lower versus 16.6% in middle versus 18.1% in higher). Consistent with this, a decisional flowchart for predicting fibrosis was suggested by combining both LSM and CAP values. In patients with NAFLD, CAP values should always be taken into account in order to avoid overestimations of liver fibrosis assessed by transient elastography. (Hepatology 2017;65:1145-1155). © 2016 by the American Association for the Study of Liver Diseases.

  9. Measuring the scale parameter of quantum chromodynamics at CHEER

    International Nuclear Information System (INIS)

    Krauss, L.M.

    1981-01-01

    The possibility of measuring the scale parameter of quantum chromodynamics, Λsub(s), at CHEER is discussed. Rationale for the measurement of this quantity are given, along with a discussion of the theoretical difficulties involved. The meaurement of the Q 2 dependence of structure functions and their moments, and methods of measuring αsub(s) and its Q 2 evolution, are discussed, and arguments are given for the advantages and disadvantages of going to high Q 2 values at CHEER. It is concluded that while sensitivity to Λ is lowered at high Q 2 , CHEER will, in principle, be able to provide the first clean measurements of Λ, free from almost all the theoretical confusion involved in interpretations of present data

  10. Resonance parameters for measured keV neutron capture cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Musgrove, A.R. de L

    1969-05-01

    All available neutron capture cross sections in the keV region ({approx} to 100 keV) have been fitted with resonance parameters. Capture cross sections for nuclides with reasonably well known average s-wave parameters, but no measured cross section, have been calculated and tabulated using p-and d- wave strength functions interpolated between fitted values. Several of these nuclides are of interest in the theory of slow nucleosynthesis of heavy elements in stars, and the product of cosmic abundance (due to the s-process) and capture cross section at 30 keV has been plotted versus mass number. (author)

  11. Online Measurement of LHC Beam Parameters with the ATLAS High Level Trigger

    CERN Document Server

    Strauss, E; The ATLAS collaboration

    2011-01-01

    We present an online measurement of the LHC beam parameters in ATLAS using the High Level Trigger (HLT). When a significant change is detected in the measured beamspot, it is distributed to the HLT. There, trigger algorithms like b-tagging which calculate impact parameters or decay lengths benefit from a precise, up-to-date set of beamspot parameters. Additionally, online feedback is sent to the LHC operators in real time. The measurement is performed by an algorithm running on the Level 2 trigger farm, leveraging the high rate of usable events. Dedicated algorithms perform a full scan of the silicon detector to reconstruct event vertices from registered tracks. The distribution of these vertices is aggregated across the farm and their shape is extracted through fits every 60 seconds to determine the beamspot position, size, and tilt. The reconstructed beam values are corrected for detector resolution effects, measured in situ using the separation of vertices whose tracks have been split into two collections....

  12. Online measurement of LHC beam parameters with the ATLAS High Level Trigger

    CERN Document Server

    Strauss, E; The ATLAS collaboration

    2011-01-01

    We present an online measurement of the LHC beam parameters in ATLAS using the High Level Trigger (HLT). When a significant change is detected in the measured beamspot, it is distributed to the HLT. There, trigger algorithms like b-tagging which calculate impact parameters or decay lengths benefit from a precise,up-to-date set of beamspot parameters. Additionally, online feedback is sent to the LHC operators in real time. The measurement is performed by an algorithm running on the Level 2 trigger farm, leveraging the high rate of usable events. Dedicated algorithms perform a full scan of the silicon detector to reconstruct event vertices from registered tracks. The distribution of these vertices is aggregated across the farm and their shape is extracted through fits every 60 seconds to determine the beamspot position, size, and tilt. The reconstructed beam values are corrected for detector resolution effects, measured in situ using the separation of vertices whose tracks have been split into two collections. ...

  13. Diffusion-weighted imaging of breast lesions: Region-of-interest placement and different ADC parameters influence apparent diffusion coefficient values

    Energy Technology Data Exchange (ETDEWEB)

    Bickel, Hubert; Pinker, Katja; Polanec, Stephan; Magometschnigg, Heinrich; Wengert, Georg; Spick, Claudio; Helbich, Thomas H.; Baltzer, Pascal [Medical University Vienna, Division of Molecular and Gender Imaging, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Bogner, Wolfgang [Medical University Vienna - MR Center of Excellence, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Bago-Horvath, Zsuzsanna [Medical University Vienna, Department of Pathology, Vienna (Austria)

    2017-05-15

    To investigate the influence of region-of-interest (ROI) placement and different apparent diffusion coefficient (ADC) parameters on ADC values, diagnostic performance, reproducibility and measurement time in breast tumours. In this IRB-approved, retrospective study, 149 histopathologically proven breast tumours (109 malignant, 40 benign) in 147 women (mean age 53.2) were investigated. Three radiologists independently measured minimum, mean and maximum ADC, each using three ROI placement approaches:1 - small 2D-ROI, 2 - large 2D-ROI and 3 - 3D-ROI covering the whole lesion. One reader performed all measurements twice. Median ADC values, diagnostic performance, reproducibility, and measurement time were calculated and compared between all combinations of ROI placement approaches and ADC parameters. Median ADC values differed significantly between the ROI placement approaches (p <.001). Minimum ADC showed the best diagnostic performance (AUC.928-.956), followed by mean ADC obtained from 2D ROIs (.926-.94). Minimum and mean ADC showed high intra- (ICC.85-.94) and inter-reader reproducibility (ICC.74-.94). Median measurement time was significantly shorter for the 2D ROIs (p <.001). ROI placement significantly influences ADC values measured in breast tumours. Minimum and mean ADC acquired from 2D-ROIs are useful for the differentiation of benign and malignant breast lesions, and are highly reproducible, with rapid measurement. (orig.)

  14. Effects of Various Architectural Parameters on Six Room Acoustical Measures in Auditoria.

    Science.gov (United States)

    Chiang, Wei-Hwa

    The effects of architectural parameters on six room acoustical measures were investigated by means of correlation analyses, factor analyses and multiple regression analyses based on data taken in twenty halls. Architectural parameters were used to estimate acoustical measures taken at individual locations within each room as well as the averages and standard deviations of all measured values in the rooms. The six acoustical measures were Early Decay Time (EDT10), Clarity Index (C80), Overall Level (G), Bass Ratio based on Early Decay Time (BR(EDT)), Treble Ratio based on Early Decay Time (TR(EDT)), and Early Inter-aural Cross Correlation (IACC80). A comprehensive method of quantifying various architectural characteristics of rooms was developed to define a large number of architectural parameters that were hypothesized to effect the acoustical measurements made in the rooms. This study quantitatively confirmed many of the principles used in the design of concert halls and auditoria. Three groups of room architectural parameters such as the parameters associated with the depth of diffusing surfaces were significantly correlated with the hall standard deviations of most of the acoustical measures. Significant differences of statistical relations among architectural parameters and receiver specific acoustical measures were found between a group of music halls and a group of lecture halls. For example, architectural parameters such as the relative distance from the receiver to the overhead ceiling increased the percentage of the variance of acoustical measures that was explained by Barron's revised theory from approximately 70% to 80% only when data were taken in the group of music halls. This study revealed the major architectural parameters which have strong relations with individual acoustical measures forming the basis for a more quantitative method for advancing the theoretical design of concert halls and other auditoria. The results of this study provide

  15. Selection of entropy-measure parameters for knowledge discovery in heart rate variability data.

    Science.gov (United States)

    Mayer, Christopher C; Bachler, Martin; Hörtenhuber, Matthias; Stocker, Christof; Holzinger, Andreas; Wassertheurer, Siegfried

    2014-01-01

    Heart rate variability is the variation of the time interval between consecutive heartbeats. Entropy is a commonly used tool to describe the regularity of data sets. Entropy functions are defined using multiple parameters, the selection of which is controversial and depends on the intended purpose. This study describes the results of tests conducted to support parameter selection, towards the goal of enabling further biomarker discovery. This study deals with approximate, sample, fuzzy, and fuzzy measure entropies. All data were obtained from PhysioNet, a free-access, on-line archive of physiological signals, and represent various medical conditions. Five tests were defined and conducted to examine the influence of: varying the threshold value r (as multiples of the sample standard deviation σ, or the entropy-maximizing rChon), the data length N, the weighting factors n for fuzzy and fuzzy measure entropies, and the thresholds rF and rL for fuzzy measure entropy. The results were tested for normality using Lilliefors' composite goodness-of-fit test. Consequently, the p-value was calculated with either a two sample t-test or a Wilcoxon rank sum test. The first test shows a cross-over of entropy values with regard to a change of r. Thus, a clear statement that a higher entropy corresponds to a high irregularity is not possible, but is rather an indicator of differences in regularity. N should be at least 200 data points for r = 0.2 σ and should even exceed a length of 1000 for r = rChon. The results for the weighting parameters n for the fuzzy membership function show different behavior when coupled with different r values, therefore the weighting parameters have been chosen independently for the different threshold values. The tests concerning rF and rL showed that there is no optimal choice, but r = rF = rL is reasonable with r = rChon or r = 0.2σ. Some of the tests showed a dependency of the test significance on the data at hand. Nevertheless, as the medical

  16. Extreme values of meteorological parameters observed at Kalpakkam during the period 1968-1999

    International Nuclear Information System (INIS)

    Balagurunathan, M.R.; Chandresekharan, E.; Rajan, M.P.; Gurg, R.P.

    2001-05-01

    In the design phase of engineering structures, an understanding of extreme weather conditions that may occur at the site of interest is very essential, so that the structures can be designed to withstand climatological stresses during its life time. In this report an analysis of extreme values of meteorological parameters at Kalpakkam for the period 1968-99, which provide an insight into such situations is described. The extreme value analysis reveals that all the variables obey Fisher-Tippet Type-I extreme value distribution function. Parameter values of extreme value analysis functions are presented for the variables studied and the 50- and 100- year return period extreme values are arrived at. Frequency distribution of rainfall parameters is investigated. Time series of annual rainfall data suggests a cycle of 2-3 years period. (author)

  17. Normal Values for Heart Electrophysiology Parameters of Healthy Swine Determined on Electrophysiology Study.

    Science.gov (United States)

    Noszczyk-Nowak, Agnieszka; Cepiel, Alicja; Janiszewski, Adrian; Pasławski, Robert; Gajek, Jacek; Pasławska, Urszula; Nicpoń, Józef

    2016-01-01

    Swine are a well-recognized animal model for human cardiovascular diseases. Despite the widespread use of porcine model in experimental electrophysiology, still no reference values for intracardiac electrical activity and conduction parameters determined during an invasive electrophysiology study (EPS) have been developed in this species thus far. The aim of the study was to develop a set of normal values for intracardiac electrical activity and conduction parameters determined during an invasive EPS of swine. The study included 36 healthy domestic swine (24-40 kg body weight). EPS was performed under a general anesthesia with midazolam, propofol and isoflurane. The reference values for intracardiac electrical activity and conduction parameters were calculated as arithmetic means ± 2 standard deviations. The reference values were determined for AH, HV and PA intervals, interatrial conduction time at its own and imposed rhythm, sinus node recovery time (SNRT), corrected sinus node recovery time (CSNRT), anterograde and retrograde Wenckebach points, atrial, atrioventricular node and ventricular refractory periods. No significant correlations were found between body weight and heart rate of the examined pigs and their electrophysiological parameters. The hereby presented reference values can be helpful in comparing the results of various studies, as well as in more accurately estimating the values of electrophysiological parameters that can be expected in a given experiment.

  18. Site-specific parameter values for the Nuclear Regulatory Commission's food pathway dose model

    International Nuclear Information System (INIS)

    Hamby, D.M.

    1992-01-01

    Routine operations at the Savannah River Site (SRS) in Western South Carolina result in radionuclide releases to the atmosphere and to the Savannah River. The resulting radiation doses to the off-site maximum individual and the off-site population within 80 km of the SRS are estimated on a yearly basis. These estimates are currently generated using dose models prescribed for the commercial nuclear power industry by the Nuclear Regulatory Commission (NRC). The NRC provides default values for dose-model parameters for facilities without resources to develop site-specific values. A survey of land- and water-use characteristics for the Savannah River area has been conducted to determine site-specific values for water recreation, consumption, and agricultural parameters used in the NRC Regulatory Guide 1.109 (1977) dosimetric models. These site parameters include local characteristics of meat, milk, and vegetable production; recreational and commercial activities on the Savannah River; and meat, milk, vegetable, and seafood consumption rates. This paper describes how parameter data were obtained at the Savannah River Site and the impacts of such data on off-site dose. Dose estimates using site-specific parameter values are compared to estimates using the NRC default values

  19. Methods for measurement of durability parameters

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place

    1996-01-01

    Present selected methods for measurement of durabilty parameters relating to chlorides, corrosion, moisture and freeze-thaw, primarly on concrete. Advantages and drawbacks of the different methods are included.......Present selected methods for measurement of durabilty parameters relating to chlorides, corrosion, moisture and freeze-thaw, primarly on concrete. Advantages and drawbacks of the different methods are included....

  20. Self-adaptive Green-Ampt infiltration parameters obtained from measured moisture processes

    Directory of Open Access Journals (Sweden)

    Long Xiang

    2016-07-01

    Full Text Available The Green-Ampt (G-A infiltration model (i.e., the G-A model is often used to characterize the infiltration process in hydrology. The parameters of the G-A model are critical in applications for the prediction of infiltration and associated rainfall-runoff processes. Previous approaches to determining the G-A parameters have depended on pedotransfer functions (PTFs or estimates from experimental results, usually without providing optimum values. In this study, rainfall simulators with soil moisture measurements were used to generate rainfall in various experimental plots. Observed runoff data and soil moisture dynamic data were jointly used to yield the infiltration processes, and an improved self-adaptive method was used to optimize the G-A parameters for various types of soil under different rainfall conditions. The two G-A parameters, i.e., the effective hydraulic conductivity and the effective capillary drive at the wetting front, were determined simultaneously to describe the relationships between rainfall, runoff, and infiltration processes. Through a designed experiment, the method for determining the G-A parameters was proved to be reliable in reflecting the effects of pedologic background in G-A type infiltration cases and deriving the optimum G-A parameters. Unlike PTF methods, this approach estimates the G-A parameters directly from infiltration curves obtained from rainfall simulation experiments so that it can be used to determine site-specific parameters. This study provides a self-adaptive method of optimizing the G-A parameters through designed field experiments. The parameters derived from field-measured rainfall-infiltration processes are more reliable and applicable to hydrological models.

  1. Influence of selected test parameters on measured values during the MSCR test

    Science.gov (United States)

    Benešová, Lucie; Valentin, Jan

    2017-09-01

    One of today’s most commonly used test on a Dynamic Shear Rheometer (DSR) is the Multiple Stress Creep Recovery (MSCR) test. The test is described in the standard EN 16659, which is valid in the Czech Republic since October 2016. The principle of the test is based on repeated loading and recovering of a bitumen sample, according to which it is possible to determine the percentage of elastic recovery (R) and non-recoverable creep compliance (Jnr) of the bituminous binder. This method has been recently promoted as the most suitable test for assessing the resistance of bituminous binders to permanent deformation. The test is performed at higher temperatures and is particularly suitable for modified bituminous binders. The paper deals with the comparison of the different input parameters set on the DSR device - different levels of stress, temperature of test, the geometry of the measuring device and also a comparison of the results for a different number of loading cycles. The research study was focused mainly on modified bituminous binders, but to compare the MSCR test it is performed even with conventional paving grade binders.

  2. A real-time measurement system for parameters of live biology metabolism process with fiber optics

    Science.gov (United States)

    Tao, Wei; Zhao, Hui; Liu, Zemin; Cheng, Jinke; Cai, Rong

    2010-08-01

    Energy metabolism is one of the basic life activities of cellular in which lactate, O2 and CO2 will be released into the extracellular environment. By monitoring the quantity of these parameters, the mitochondrial performance will be got. A continuous measurement system for the concentration of O2, CO2 and PH value is introduced in this paper. The system is made up of several small-sized fiber optics biosensors corresponding to the container. The setup of the system and the principle of measurement of several parameters are explained. The setup of the fiber PH sensor based on principle of light absorption is also introduced in detail and some experimental results are given. From the results we can see that the system can measure the PH value precisely suitable for cell cultivation. The linear and repeatable accuracies are 3.6% and 6.7% respectively, which can fulfill the measurement task.

  3. Precision measurements of thermodynamic parameters of heavy alkali metals

    Science.gov (United States)

    Blagonravov, L. A.; Modenov, A. A.

    2017-11-01

    On the temperature dependences of a number of one-component liquids, regions of anomalous behavior in the form of kinks and also in the form of limited areas of forced growth have been previously observed (LA Blagonravov, LA Orlov, et al., TVT 2000, vol. 38, No. 4, p.566-572). However, the interpretation of these anomalies is complicated by the small magnitude of the effects themselves (the magnitude of the observed effect was 5%, a random error of 2-3%). An increase in the accuracy of measurements is required for a more confident determination of the detailed shape of the anomalies. In the proposed work, thermodynamic parameters are studied using a technique that uses the elastic-thermal effect. The adiabatic thermal coefficient of pressure (a.t.p.c.) is measured: χ = (1/T)(∂T/∂p)S. An installation in which the pressure change is carried out in a periodic mode is used for measurements. The software allows simultaneous averaging of the values of the amplitude of pressure oscillations and the amplitude of temperature response oscillations with the subsequent determination of their ratio. The facility uses an advanced pressure modulator, which allows creating pressure oscillations of the shape close to sinusoidal (the value of the second harmonic is not more than 10%) and a precision SR-810 nanovoltmeter with a synchronous digital detector. The currently used technique provides an acceptable measurement accuracy (error in the region of 0.5-1%). However, to further increase the accuracy, it was decided to make changes in the measuring path. Namely, by developing and applying a scheme of a precision low-noise preamplifier based on the instrument amplifier INA333, a circuit allowing simultaneous measurement of not only the two above parameters but also the current temperature of the sample (to exclude the effect of temperature drift.) Preliminary results of measurements of the temperature dependence of the a.t.p.c. of liquid cesium in the temperature range up to

  4. A step-by-step plan to manage and measure adding value by FM/CREM

    DEFF Research Database (Denmark)

    van der Voordt, Theo; Jensen, Per Anker; Hoendervanger, Jan Gerard

    2016-01-01

    Purpose To present a new Value Adding Management model in order to support decision makers in identifying appropriate interventions to add value to the organisation, to manage its implementation, and to measure the output and outcomes. Theory The paper builds on value adding management theories...... different European countries present a state of the art of theory and research on 12 value parameters, how to manage and measure each value, and to discuss the costs and benefits of typical FM and CREM interventions to enhance satisfaction, image, culture, health and safety, productivity, adaptability...... and models including the triplet input-throughput-output, a distinction between output, outcome and added value, the Plan-Do-Act-Check cycle, change management and performance measurement. Design/methodology/approach Literature review and a cross-chapter analysis of a forthcoming book, where authors from...

  5. Average values of 235U resonance parameters up to 500 eV

    International Nuclear Information System (INIS)

    Leal, L.C.

    1991-01-01

    An R-matrix analysis of 235 U neutron cross sections was recently completed. The analysis was performed with the multilevel-multichannel Reich-Moore computer code SAMMY and extended the resolved resonance region up to 500 eV. Several high resolution measurements namely, transmission, fission and capture data as well as spin separated fission data were analyzed in a consistent manner and a very accurate parametrization up to 500 eV of these data were obtained. The aim of this paper is to present the results of average values of the resonance parameters. 9 refs., 1 tab

  6. Measurement-based perturbation theory and differential equation parameter estimation with applications to satellite gravimetry

    Science.gov (United States)

    Xu, Peiliang

    2018-06-01

    The numerical integration method has been routinely used by major institutions worldwide, for example, NASA Goddard Space Flight Center and German Research Center for Geosciences (GFZ), to produce global gravitational models from satellite tracking measurements of CHAMP and/or GRACE types. Such Earth's gravitational products have found widest possible multidisciplinary applications in Earth Sciences. The method is essentially implemented by solving the differential equations of the partial derivatives of the orbit of a satellite with respect to the unknown harmonic coefficients under the conditions of zero initial values. From the mathematical and statistical point of view, satellite gravimetry from satellite tracking is essentially the problem of estimating unknown parameters in the Newton's nonlinear differential equations from satellite tracking measurements. We prove that zero initial values for the partial derivatives are incorrect mathematically and not permitted physically. The numerical integration method, as currently implemented and used in mathematics and statistics, chemistry and physics, and satellite gravimetry, is groundless, mathematically and physically. Given the Newton's nonlinear governing differential equations of satellite motion with unknown equation parameters and unknown initial conditions, we develop three methods to derive new local solutions around a nominal reference orbit, which are linked to measurements to estimate the unknown corrections to approximate values of the unknown parameters and the unknown initial conditions. Bearing in mind that satellite orbits can now be tracked almost continuously at unprecedented accuracy, we propose the measurement-based perturbation theory and derive global uniformly convergent solutions to the Newton's nonlinear governing differential equations of satellite motion for the next generation of global gravitational models. Since the solutions are global uniformly convergent, theoretically speaking

  7. The effect of intake of water on the final values of body composition parameters in active athletes using two different bioimpedance analyzers

    Directory of Open Access Journals (Sweden)

    Petr Kutáč

    2014-06-01

    Full Text Available Background:The method of bioelectrical impedance (BIA is frequently used to estimate body composition in sports. The total body water (TBW is the basic variable that BIA measures. That implies the degree of sensitivity of BIA to the hydration of the organism, which is also demonstrated by the principles of measurement that primarily relate to the hydration of the organism. It is difficult to provide standard hydration of the organism of subjects prior to measurements when taking the measurements in the field. Objective:The objective of the study is to assess the changes in the final values of the selected body composition parameters in soccer players caused by intake of water, using two devices commonly used in the field. Methods:The research was performed in a group of 33 soccer players (mean age 20.30 ± 1.18 years. The measurements were taken using Tanita BC 418 MA (frequency 50 kHz and Nutriguard-M (frequency 100 kHz. To evaluate the effect of water intake, we took two measurements before and after the intake of 500 ml of water. The parameters measured by Tanita BC 418 MA were body weight (BW, total body water (TBW, body fat (BF, fat free mass (FFM. Nutriguard-M was used to measure total body water (TBW, intra and extracellular water (ICW and ECW, body fat (BF, fat free mass (FFM, intra and extracellular mass (BCM and ECM. The differences in the means (M1 and M2 of the monitored parameters were evaluated using the Paired Samples t-test. In statistically significant differences in the mean, the practical significance was also verified using the effect of size (Cohen's d. Results:The Tanita device showed statistically significant differences after the intake of 500 ml in parameters BW (+0.42 kg, BF (+0.39 kg, +0.53% and TBW (-0.38%. As for the Nutriguard device, statistically significant differences were found in parameters TBW (+0.77 kg, ICW (+0.83 kg, FFM (+1.05 kg, BCM (+0.79 kg and ECM/BCM (-0.01. Conclusion

  8. Standardized perfusion value of the esophageal carcinoma and its correlation with quantitative CT perfusion parameter values

    Energy Technology Data Exchange (ETDEWEB)

    Djuric-Stefanovic, A., E-mail: avstefan@eunet.rs [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Saranovic, Dj., E-mail: crvzve4@gmail.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Sobic-Saranovic, D., E-mail: dsobic2@gmail.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Center of Nuclear Medicine, Clinical Center of Serbia, Belgrade (Serbia); Masulovic, D., E-mail: draganmasulovic@yahoo.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Artiko, V., E-mail: veraart@beotel.rs [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Center of Nuclear Medicine, Clinical Center of Serbia, Belgrade (Serbia)

    2015-03-15

    Purpose: Standardized perfusion value (SPV) is a universal indicator of tissue perfusion, normalized to the whole-body perfusion, which was proposed to simplify, unify and allow the interchangeability among the perfusion measurements and comparison between the tumor perfusion and metabolism. The aims of our study were to assess the standardized perfusion value (SPV) of the esophageal carcinoma, and its correlation with quantitative CT perfusion measurements: blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) of the same tumor volume samples, which were obtained by deconvolution-based CT perfusion analysis. Methods: Forty CT perfusion studies of the esophageal cancer were analyzed, using the commercial deconvolution-based CT perfusion software (Perfusion 3.0, GE Healthcare). The SPV of the esophageal tumor and neighboring skeletal muscle were correlated with the corresponding mean tumor and muscle quantitative CT perfusion parameter values, using Spearman's rank correlation coefficient (r{sub S}). Results: Median SPV of the esophageal carcinoma (7.1; range: 2.8–13.4) significantly differed from the SPV of the skeletal muscle (median: 1.0; range: 0.4–2.4), (Z = −5.511, p < 0.001). The cut-off value of the SPV of 2.5 enabled discrimination of esophageal cancer from the skeletal muscle with sensitivity and specificity of 100%. SPV of the esophageal carcinoma significantly correlated with corresponding tumor BF (r{sub S} = 0.484, p = 0.002), BV (r{sub S} = 0.637, p < 0.001) and PS (r{sub S} = 0.432, p = 0.005), and SPV of the skeletal muscle significantly correlated with corresponding muscle BF (r{sub S} = 0.573, p < 0.001), BV (r{sub S} = 0.849, p < 0.001) and PS (r{sub S} = 0.761, p < 0.001). Conclusions: We presented a database of the SPV for the esophageal cancer and proved that SPV of the esophageal neoplasm significantly differs from the SPV of the skeletal muscle, which represented a sample of healthy

  9. Reference values of clinical chemistry and hematology parameters in rhesus monkeys (Macaca mulatta).

    Science.gov (United States)

    Chen, Younan; Qin, Shengfang; Ding, Yang; Wei, Lingling; Zhang, Jie; Li, Hongxia; Bu, Hong; Lu, Yanrong; Cheng, Jingqiu

    2009-01-01

    Rhesus monkey models are valuable to the studies of human biology. Reference values for clinical chemistry and hematology parameters of rhesus monkeys are required for proper data interpretation. Whole blood was collected from 36 healthy Chinese rhesus monkeys (Macaca mulatta) of either sex, 3 to 5 yr old. Routine chemistry and hematology parameters, and some special coagulation parameters including thromboelastograph and activities of coagulation factors were tested. We presented here the baseline values of clinical chemistry and hematology parameters in normal Chinese rhesus monkeys. These data may provide valuable information for veterinarians and investigators using rhesus monkeys in experimental studies.

  10. Precision measurements of electroweak parameters

    CERN Document Server

    Savin, Alexander

    2017-01-01

    A set of selected precise measurements of the SM parameters from the LHC experiments is discussed. Results on W-mass measurement and forward-backward asymmetry in production of the Drell--Yan events in both dielectron and dimuon decay channels are presented together with results on the effective mixing angle measurements. Electroweak production of the vector bosons in association with two jets is discussed.

  11. The Impact of Variability of Selected Geological and Mining Parameters on the Value and Risks of Projects in the Hard Coal Mining Industry

    Science.gov (United States)

    Kopacz, Michał

    2017-09-01

    The paper attempts to assess the impact of variability of selected geological (deposit) parameters on the value and risks of projects in the hard coal mining industry. The study was based on simulated discounted cash flow analysis, while the results were verified for three existing bituminous coal seams. The Monte Carlo simulation was based on nonparametric bootstrap method, while correlations between individual deposit parameters were replicated with use of an empirical copula. The calculations take into account the uncertainty towards the parameters of empirical distributions of the deposit variables. The Net Present Value (NPV) and the Internal Rate of Return (IRR) were selected as the main measures of value and risk, respectively. The impact of volatility and correlation of deposit parameters were analyzed in two aspects, by identifying the overall effect of the correlated variability of the parameters and the indywidual impact of the correlation on the NPV and IRR. For this purpose, a differential approach, allowing determining the value of the possible errors in calculation of these measures in numerical terms, has been used. Based on the study it can be concluded that the mean value of the overall effect of the variability does not exceed 11.8% of NPV and 2.4 percentage points of IRR. Neglecting the correlations results in overestimating the NPV and the IRR by up to 4.4%, and 0.4 percentage point respectively. It should be noted, however, that the differences in NPV and IRR values can vary significantly, while their interpretation depends on the likelihood of implementation. Generalizing the obtained results, based on the average values, the maximum value of the risk premium in the given calculation conditions of the "X" deposit, and the correspondingly large datasets (greater than 2500), should not be higher than 2.4 percentage points. The impact of the analyzed geological parameters on the NPV and IRR depends primarily on their co-existence, which can be

  12. Measuring the chargino parameters

    Indian Academy of Sciences (India)

    by measuring the cross-sections with polarized beams at e+e- collider ... is given by the fundamental SUSY parameters: the SU(2) gaugino mass Е¾, the higgsino .... two points in the plane which are symmetric under the interchange ¾Д ° ¾К.

  13. Recommended food chain parameter values and distributions for use around CANDU sites in Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, S R

    1996-07-01

    Site-specific parameter values should be used whenever possible to increase the accuracy of dose predictions. Parameter values specific to agricultural practices and human lifestyles in southern Ontario are presented for use in CSA-N288.1-M87 (Canadian Standards Association Guidelines for Calculating Derived Release Limits for Radioactive Material in Airborne and Liquid Effluents for Normal Operation of Nuclear Facilities) and CHERPAC (Chalk River Environmental Research Pathways Analysis Code). Use of these values in place of the default parameter values in CSA-N288.1-M87 is shown to reduce the predicted dose by nearly a factor of 2. (author). 27 refs., 6 tabs., 1 fig.

  14. Recommended food chain parameter values and distributions for use around CANDU sites in Ontario

    International Nuclear Information System (INIS)

    Peterson, S.R.

    1996-07-01

    Site-specific parameter values should be used whenever possible to increase the accuracy of dose predictions. Parameter values specific to agricultural practices and human lifestyles in southern Ontario are presented for use in CSA-N288.1-M87 (Canadian Standards Association Guidelines for Calculating Derived Release Limits for Radioactive Material in Airborne and Liquid Effluents for Normal Operation of Nuclear Facilities) and CHERPAC (Chalk River Environmental Research Pathways Analysis Code). Use of these values in place of the default parameter values in CSA-N288.1-M87 is shown to reduce the predicted dose by nearly a factor of 2. (author). 27 refs., 6 tabs., 1 fig

  15. Estimation of the value-at-risk parameter: Econometric analysis and the extreme value theory approach

    Directory of Open Access Journals (Sweden)

    Mladenović Zorica

    2006-01-01

    Full Text Available In this paper different aspects of value-at-risk estimation are considered. Daily returns of CISCO, INTEL and NASDAQ stock indices are analyzed for period: September 1996 - September 2006. Methods that incorporate time varying variability and heavy tails of the empirical distributions of returns are implemented. The main finding of the paper is that standard econometric methods underestimate the value-at-risk parameter if heavy tails of the empirical distribution are not explicitly taken into account. .

  16. Diagnostic value of hematological parameters in patients with osteoarthritis

    Directory of Open Access Journals (Sweden)

    Serdar Hira

    2017-03-01

    Results: There were no significant differences in WBC, RDW, PLT, RPR levels between two groups. NLR and PLR values were significantly higher in the osteoarthritis group than in the control group. RBC, MPV and PDW values were significantly lower in the osteoarthritis group than in the control group (all . MPV and RBC were negatively correlated with ESR and CRP in osteoarthritis patients. Conclusion: Hematological inflammatory markers might be useful parameters that could be used in patients with osteoarthritis. [Cukurova Med J 2017; 42(1.000: 120-125

  17. Reconciling Planck with the local value of H0 in extended parameter space

    Directory of Open Access Journals (Sweden)

    Eleonora Di Valentino

    2016-10-01

    Full Text Available The recent determination of the local value of the Hubble constant by Riess et al., 2016 (hereafter R16 is now 3.3 sigma higher than the value derived from the most recent CMB anisotropy data provided by the Planck satellite in a ΛCDM model. Here we perform a combined analysis of the Planck and R16 results in an extended parameter space, varying simultaneously 12 cosmological parameters instead of the usual 6. We find that a phantom-like dark energy component, with effective equation of state w=−1.29−0.12+0.15 at 68% c.l. can solve the current tension between the Planck dataset and the R16 prior in an extended ΛCDM scenario. On the other hand, the neutrino effective number is fully compatible with standard expectations. This result is confirmed when including cosmic shear data from the CFHTLenS survey and CMB lensing constraints from Planck. However, when BAO measurements are included we find that some of the tension with R16 remains, as also is the case when we include the supernova type Ia luminosity distances from the JLA catalog.

  18. DEVELOPMENT OF VADOSE-ZONE HYDRAULIC PARAMETER VALUES

    Energy Technology Data Exchange (ETDEWEB)

    ROGERS PM

    2008-01-21

    Several approaches have been developed to establish a relation between the soil-moisture retention curve and readily available soil properties. Those relationships are referred to as pedotransfer functions. Described in this paper are the rationale, approach, and corroboration for use of a nonparametric pedotransfer function for the estimation of soil hydraulic-parameter values at the yucca Mountain area in Nevada for simulations of net infiltration. This approach, shown to be applicable for use at Yucca Mountain, is also applicable for use at the Hanford Site where the underlying data were collected.

  19. DEVELOPMENT OF VADOSE ZONE HYDRAULIC PARAMETER VALUES

    International Nuclear Information System (INIS)

    ROGERS PM

    2008-01-01

    Several approaches have been developed to establish a relation between the soil-moisture retention curve and readily available soil properties. Those relationships are referred to as pedotransfer functions. Described in this paper are the rationale, approach, and corroboration for use of a nonparametric pedotransfer function for the estimation of soil hydraulic-parameter values at the yucca Mountain area in Nevada for simulations of net infiltration. This approach, shown to be applicable for use at Yucca Mountain, is also applicable for use at the Hanford Site where the underlying data were collected

  20. Efficiently enclosing the compact binary parameter space by singular-value decomposition

    International Nuclear Information System (INIS)

    Cannon, Kipp; Hanna, Chad; Keppel, Drew

    2011-01-01

    Gravitational-wave searches for the merger of compact binaries use matched filtering as the method of detecting signals and estimating parameters. Such searches construct a fine mesh of filters covering a signal parameter space at high density. Previously it has been shown that singular-value decomposition can reduce the effective number of filters required to search the data. Here we study how the basis provided by the singular-value decomposition changes dimension as a function of template-bank density. We will demonstrate that it is sufficient to use the basis provided by the singular-value decomposition of a low-density bank to accurately reconstruct arbitrary points within the boundaries of the template bank. Since this technique is purely numerical, it may have applications to interpolating the space of numerical relativity waveforms.

  1. Parameter measurement of target

    International Nuclear Information System (INIS)

    Gao Dangzhong

    2001-01-01

    The progress of parameter measurement of target (ICF-15) in 1999 are presented, including the design and contract of the microsphere equator profiler, the precise air bearing manufacturing, high-resolution X-ray image of multi-layer shells and the X-ray photos processed with special image and data software, some plastic shells measured in precision of 0.3 μm, the high-resolution observation and photograph system of 'dew-point method', special fixture of target and its temperature distribution measuring, the dew-point temperature and fuel gas pressure of shells measuring with internal pressure of 5 - 15 (x10 5 ) Pa D 2 and wall thickness of 1.5∼3 μm

  2. Assessment of Optimum Value for Dip Angle and Locking Rate Parameters in Makran Subduction Zone

    Science.gov (United States)

    Safari, A.; Abolghasem, A. M.; Abedini, N.; Mousavi, Z.

    2017-09-01

    Makran subduction zone is one of the convergent areas that have been studied by spatial geodesy. Makran zone is located in the South Eastern of Iran and South of Pakistan forming the part of Eurasian-Arabian plate's border where oceanic crust in the Arabian plate (or in Oman Sea) subducts under the Eurasian plate ( Farhoudi and Karig, 1977). Due to lack of historical and modern tools in the area, a sampling of sparse measurements of the permanent GPS stations and temporary stations (campaign) has been conducted in the past decade. Makran subduction zone from different perspectives has unusual behaviour: For example, the Eastern and Western parts of the region have very different seismicity and also dip angle of subducted plate is in about 2 to 8 degrees that this value due to the dip angle in other subduction zone is very low. In this study, we want to find the best possible value for parameters that differs Makran subduction zone from other subduction zones. Rigid block modelling method was used to determine these parameters. From the velocity vectors calculated from GPS observations in this area, block model is formed. These observations are obtained from GPS stations that a number of them are located in South Eastern Iran and South Western Pakistan and a station located in North Eastern Oman. According to previous studies in which the locking depth of Makran subduction zone is 38km (Frohling, 2016), in the preparation of this model, parameter value of at least 38 km is considered. With this function, the amount of 2 degree value is the best value for dip angle but for the locking rate there is not any specified amount. Because the proposed model is not sensitive to this parameter. So we can not expect big earthquakes in West of Makran or a low seismicity activity in there but the proposed model definitely shows the Makran subduction layer is locked.

  3. On set-valued functionals: Multivariate risk measures and Aumann integrals

    Science.gov (United States)

    Ararat, Cagin

    particular, it is shown that a shortfall risk measure can be written as an intersection over a family of divergence risk measures indexed by a scalarization parameter. Examples include the multivariate versions of the entropic risk measure and the average value at risk. In the second part, Aumann integrals of set-valued functions on a measurable space are viewed as set-valued functionals and a Daniell-Stone type characterization theorem is proved for such functionals. More precisely, it is shown that a functional that maps measurable set-valued functions into a certain complete lattice of subsets of Rm can be written as the Aumann integral with respect to a measure if and only if the functional is (1) additive and (2) positively homogeneous, (3) it preserves decreasing limits, (4) it maps halfspace-valued functions to halfspaces, and (5) it maps shifted cone-valued functions to shifted cones. While the first three properties already exist in the classical Daniell-Stone theorem for the Lebesgue integral, the last two properties are peculiar to the set-valued framework and they suffice to complement the first three properties to identify a set-valued functional as the Aumann integral with respect to a measure.

  4. Prediction of betavoltaic battery output parameters based on SEM measurements and Monte Carlo simulation

    International Nuclear Information System (INIS)

    Yakimov, Eugene B.

    2016-01-01

    An approach for a prediction of "6"3Ni-based betavoltaic battery output parameters is described. It consists of multilayer Monte Carlo simulation to obtain the depth dependence of excess carrier generation rate inside the semiconductor converter, a determination of collection probability based on the electron beam induced current measurements, a calculation of current induced in the semiconductor converter by beta-radiation, and SEM measurements of output parameters using the calculated induced current value. Such approach allows to predict the betavoltaic battery parameters and optimize the converter design for any real semiconductor structure and any thickness and specific activity of beta-radiation source. - Highlights: • New procedure for betavoltaic battery output parameters prediction is described. • A depth dependence of beta particle energy deposition for Si and SiC is calculated. • Electron trajectories are assumed isotropic and uniformly started under simulation.

  5. Comparison of LOFT zero power physics testing measurement results with predicted values

    International Nuclear Information System (INIS)

    Rushton, B.L.; Howe, T.M.

    1978-01-01

    The results of zero power physics testing measurements in LOFT have been evaluated to assess the adequacy of the physics data used in the safety analyses performed for the LOFT FSAR and Technical Specifications. Comparisons of measured data with computed data were made for control rod worths, temperature coefficients, boron worths, and pressure coefficients. Measured boron concentrations at exact critical points were compared with predicted concentrations. Based on these comparisons, the reactivity parameter values used in the LOFT safety analyses were assessed for conservatism

  6. Footprint parameters as a measure of arch height.

    Science.gov (United States)

    Hawes, M R; Nachbauer, W; Sovak, D; Nigg, B M

    1992-01-01

    The human foot has frequently been categorized into arch height groups based upon analysis of footprint parameters. This study investigates the relationship between directly measured arch height and many of the footprint parameters that have been assumed to represent arch height. A total of 115 male subjects were measured and footprint parameters were calculated from digitized outlines. Correlation and regression analyses were used to determine the relationship between footprint measures and arch height. It may be concluded from the results that footprint parameters proposed in the literature (arch angle, footprint index, and arch index) and two further parameters suggested in this study (arch length index and truncated arch index) are invalid as a basis for prediction or categorization of arch height. The categorization of the human foot according to the footprint measures evaluated in this paper represent no more than indices and angles of the plantar surface of the foot itself.

  7. Safeguards systems parameters

    International Nuclear Information System (INIS)

    Avenhaus, R.; Heil, J.

    1979-01-01

    In this paper analyses are made of the values of those parameters that characterize the present safeguards system that is applied to a national fuel cycle; those values have to be fixed quantitatively so that all actions of the safeguards authority are specified precisely. The analysis starts by introducing three categories of quantities: The design parameters (number of MBAs, inventory frequency, variance of MUF, verification effort and false-alarm probability) describe those quantities whose values have to be specified before the safeguards system can be implemented. The performance criteria (probability of detection, expected detection time, goal quantity) measure the effectiveness of a safeguards system; and the standards (threshold amount and critical time) characterize the magnitude of the proliferation problem. The means by which the values of the individual design parameters can be determined with the help of the performance criteria; which qualitative arguments can narrow down the arbitrariness of the choice of values of the remaining parameters; and which parameter values have to be fixed more or less arbitrarily, are investigated. As a result of these considerations, which include the optimal allocation of a given inspection effort, the problem of analysing the structure of the safeguards system is reduced to an evaluation of the interplay of only a few parameters, essentially the quality of the measurement system (variance of MUF), verification effort, false-alarm probability, goal quantity and probability of detection

  8. Effects of X-ray tube parameters on thickness measure precision in X-ray profile gauge

    International Nuclear Information System (INIS)

    Miao Jichen; Wu Zhifang; Xing Guilai

    2011-01-01

    Instantaneous profile gauge technology has been widely used in metallurgy industry because it can on-line get the profile of steel strip. It has characters of high measure precision and wide measure range, but the X-ray tube parameters only can be set few different values during measurement. The relations of thickness measure precision and X-ray tube current, X-ray tube voltage were analyzed. The results show that the X-ray tube current affects the thickness measure precision and the X-ray tube voltage determines the thickness measure range. The method of estimating the X-ray current by thickness measure precision was provided in the end. This method is the base of X-ray source selection and X-ray source parameter's setting in the instantaneous profile gauge. (authors)

  9. Handbook of parameter values for the prediction of radionuclide transfer to wildlife

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-06-15

    This handbook provides generic parameter values for estimating the transfer of radionuclides from environmental media to wildlife for the purpose of assessing potential radiation exposure under equilibrium conditions. These data are intended for use where site specific data are either not available or not required, and to parameterize generic assessment models. They are based on a comprehensive review of the available literature, including many Russian language publications that have not previously been available in English. The publication addresses the limitations of the parameter values and the applicability of data. Some general background information on the assessment of potential impacts of radioactive releases on wildlife is also included. It complements the existing handbook in the same IAEA series with parameter to assess the radiological impact to humans.

  10. Correlating substituent parameter values to electron transport properties of molecules

    International Nuclear Information System (INIS)

    Vedova-Brook, Natalie; Matsunaga, Nikita; Sohlberg, Karl

    2004-01-01

    There are a vast number of organic compounds that could be considered for use in molecular electronics. Because of this, the need for efficient and economical screening tools has emerged. We demonstrate that the substituent parameter values (σ), commonly found in advanced organic chemistry textbooks, correlate strongly with features of the charge migration process, establishing them as useful indicators of electronic properties. Specifically, we report that ab initio derived electronic charge transfer values for 16 different substituted aromatic molecules for molecular junctions correlate to the σ values with a correlation coefficient squared (R 2 ) of 0.863

  11. Prognostic value of volumetric metabolic parameters measured by [18F]Fluorodeoxyglucose-positron emission tomography/computed tomography in patients with small cell lung cancer

    Science.gov (United States)

    2014-01-01

    Background We evaluated the prognostic value of volume-based metabolic positron emission tomography (PET) parameters in patients with small cell lung cancer (SCLC) compared with other factors. Methods The subjects were 202 patients with pathologically proven SCLC who underwent pretreatment 18F-fluorodeoxyglucose (FDG) PET/computed tomography (CT). Volumetric metabolic parameters of intrathoracic malignant hypermetabolic lesions, including maximum and average standardized uptake value, sum of metabolic tumor volume (MTV), and sum of total lesion glycolysis (TLG) were measured. Results 164 patients had died during follow-up (median 17.4 months) and median overall survival was 14 months. On univariate survival analysis, age, stage, treatment modality, sum of MTV (cutoff = 100 cm3), and sum of TLG (cutoff = 555) were significant predictors of survival. There was a very high correlation between the sum of MTV and the sum of TLG (r = 0.963, P < 0.001). On multivariate survival analysis, age (HR = 1.04, P < 0.001), stage (HR = 2.442, P < 0.001), and sum of MTV (HR = 1.662, P = 0.002) were independent prognostic factors. On subgroup analysis based on limited disease (LD) and extensive disease (ED), sum of MTV and sum of TLG were significant prognostic factors only in LD. Conclusion Both sum of MTV and sum of TLG of intrathoracic malignant hypermetabolic lesions are important independent prognostic factors for survival in patients with SCLC, in addition to age and clinical stage. However, it may be more useful in limited disease rather than in extensive disease. PMID:25609313

  12. ECOS: values of parameters to be used for domestic animals

    International Nuclear Information System (INIS)

    Thorne, M.C.

    1984-03-01

    This report constitutes the database description for the domestic animals section of the biosphere code ECOS. Two categories of data are supplied, element-independent and element-dependent. The element-independent data comprise rates of food, water and soil consumption, inhalation rates and masses of animal tissues. The element-dependent data consist of f 1 (fractional gastrointestinal absorption), fsub(D) (fractional systematic deposition after inhalation) and NRF (weighted integrated retention function) values. All parameter values given are justified. (author)

  13. A New Five-Parameter Fréchet Model for Extreme Values

    Directory of Open Access Journals (Sweden)

    Muhammad Ahsan ul Haq

    2017-09-01

    Full Text Available A new five parameter Fréchet model for Extreme Values was proposed and studied. Various mathematical properties including moments, quantiles, and moment generating function were derived. Incomplete moments and probability weighted moments were also obtained. The maximum likelihood method was used to estimate the model parameters. The flexibility of the derived model was accessed using two real data set applications.

  14. Transmission Electron Microscope Measures Lattice Parameters

    Science.gov (United States)

    Pike, William T.

    1996-01-01

    Convergent-beam microdiffraction (CBM) in thermionic-emission transmission electron microscope (TEM) is technique for measuring lattice parameters of nanometer-sized specimens of crystalline materials. Lattice parameters determined by use of CBM accurate to within few parts in thousand. Technique developed especially for use in quantifying lattice parameters, and thus strains, in epitaxial mismatched-crystal-lattice multilayer structures in multiple-quantum-well and other advanced semiconductor electronic devices. Ability to determine strains in indivdual layers contributes to understanding of novel electronic behaviors of devices.

  15. Diagnostic efficacy for coronary in-stent patency with parameters defined on Hounsfield CT value-spatial profile curves

    International Nuclear Information System (INIS)

    Yamazaki, Tadashi; Suzuki, Jun-ichi; Shimamoto, Ryoichi; Tsuji, Taeko; Ohmoto-Sekine, Yuki; Morita, Toshihiro; Yamashita, Hiroshi; Honye, Junko; Nagai, Ryozo; Komatsu, Shuhei; Akahane, Masaaki; Ohtomo, Kuni

    2008-01-01

    Purpose: Hounsfield CT values across coronary CT angiograms constitute CT value-spatial profile curves. These CT profile curves are independent of window settings, and therefore, parameters derived from the curves can be used for objective anatomic analyses. Applicability of parameters derived from the curves to quantification of coronary in-stent patency has not yet been evaluated. Methods: Twenty-five CT value-spatial profile curves were delineated from 10 consecutive coronary stents to test correlation between the curve derived parameter (i.e., the minimum extreme value normalized by dividing by the maximum value of the curves obtained at neighboring outside of stents) and three intravascular ultrasound (IVUS) parameters. Results: Correlation coefficients between normalized minimum extreme value of CT value-spatial profile curves and three IVUS parameters (such as patent cross-sectional in-stent area, the percentage of patent cross-sectional in-stent area, and coronary artery intra-stent diameter) were 0.65 (p < 0.01), 0.44 (p < 0.05) and 0.51 (p < 0.05), respectively. Conclusions: CT parameters defined on Hounsfield CT value-spatial profile curves correlated significantly with IVUS parameters for quantitative coronary in-stent patency. A new approach with CT coronary angiography is therefore indicated for the noninvasive assessment of in-stent re-stenosis

  16. Online measurement of LHC beam parameters with the ATLAS High Level Trigger

    International Nuclear Information System (INIS)

    Strauss, E

    2012-01-01

    We present an online measurement of the LHC beamspot parameters in ATLAS using the High Level Trigger (HLT). When a significant change is detected in the measured beamspot, it is distributed to the HLT. There, trigger algorithms like b-tagging which calculate impact parameters or decay lengths benefit from a precise, up-to-date set of beamspot parameters. Additionally, online feedback is sent to the LHC operators in real time. The measurement is performed by an algorithm running on the Level 2 trigger farm, leveraging the high rate of usable events. Dedicated algorithms perform a full scan of the silicon detector to reconstruct event vertices from registered tracks. The distribution of these vertices is aggregated across the farm and their shape is extracted through fits every 60 seconds to determine the beamspot position, size, and tilt. The reconstructed beamspot values are corrected for detector resolution effects, measured in situ using the separation of vertices whose tracks have been split into two collections. Furthermore, measurements for individual bunch crossings have allowed for studies of single-bunch distributions as well as the behavior of bunch trains. This talk will cover the constraints imposed by the online environment and describe how these measurements are accomplished with the given resources. The algorithm tasks must be completed within the time constraints of the Level 2 trigger, with limited CPU and bandwidth allocations. This places an emphasis on efficient algorithm design and the minimization of data requests.

  17. The values of the parameters of some multilayer distributed RC null networks

    Science.gov (United States)

    Huelsman, L. P.; Raghunath, S.

    1974-01-01

    In this correspondence, the values of the parameters of some multilayer distributed RC notch networks are determined, and the usually accepted values are shown to be in error. The magnitude of the error is illustrated by graphs of the frequency response of the networks.

  18. Extreme value analysis of meterological parameters observed at Narora during the period 1989-2001

    International Nuclear Information System (INIS)

    Varakhedkar, V.K.; Dube, B.; Gurg, R.P.

    2002-08-01

    The design of engineering structures requires an understanding of extreme weather conditions that may occur at the site of interest, which is very essential, so that the structures can be designed to withstand weather stresses. In this report an analysis of extreme values of meteorological parameters observed at Narora for the period 1989- 2001 is described. The parameters considered are maximum and minimum air temperature, minimum relative humidity, maximum wind speed, maximum rainfall in a day and month, and annual rainfall. The extreme value analysis reveals that the variables such as annual maximum air temperature, minimum relative humidity and monthly maximum rainfall obey Fisher -Tippet Type -I extreme value distribution where as annual minimum air temperature, maximum hourly wind speed, daily maximum rainfall and maximum and minimum annual rainfall, obey Fisher -Tippet Type -2 extreme value distribution function. Various distribution function parameters for each variable are determined. Extreme values corresponding to return periods of 50 years and 100 years are worked out. These derived extreme values are particularly useful for arriving at suitable design values to ensure the safety of any civil structure in Narora area with respect to stresses due to weather conditions. (author)

  19. Parameters for HL-LHC aperture calculations and comparison with aperture measurements

    CERN Document Server

    Bruce, R; Fartoukh, S; Giovannozzi, M; Redaelli, S; Tomas, R; Wenninger, J

    2014-01-01

    When β∗ is squeezed to smaller values in the LHC, the beam size in the inner triplet increases so that the aperture risks to be exposed to unwanted beam losses. A 2D calculation model was used during the design stage to study the aperture margins, both there and at other potential bottlenecks. Based on assumptions on orbit and optics errors, as well as mechanical tolerances, it gives the available aperture in units of the RMS beam size, which can be compared with what can be protected by the collimation system. During the LHC Run I in 2010-2013, several of the error tolerances have been found smaller than the design assumptions. Furthermore, the aperture has been measured with beam several times and the results are compatible with a very well aligned machine, with results close to the design values. In this report, we therefore review the assumptions in the model and propose an updated set of input parameters to be used for aperture calculations at top energy in HL-LHC. The new parameter set is based on th...

  20. Effects of correcting missing daily feed intake values on the genetic parameters and estimated breeding values for feeding traits in pigs.

    Science.gov (United States)

    Ito, Tetsuya; Fukawa, Kazuo; Kamikawa, Mai; Nikaidou, Satoshi; Taniguchi, Masaaki; Arakawa, Aisaku; Tanaka, Genki; Mikawa, Satoshi; Furukawa, Tsutomu; Hirose, Kensuke

    2018-01-01

    Daily feed intake (DFI) is an important consideration for improving feed efficiency, but measurements using electronic feeder systems contain many missing and incorrect values. Therefore, we evaluated three methods for correcting missing DFI data (quadratic, orthogonal polynomial, and locally weighted (Loess) regression equations) and assessed the effects of these missing values on the genetic parameters and the estimated breeding values (EBV) for feeding traits. DFI records were obtained from 1622 Duroc pigs, comprising 902 individuals without missing DFI and 720 individuals with missing DFI. The Loess equation was the most suitable method for correcting the missing DFI values in 5-50% randomly deleted datasets among the three equations. Both variance components and heritability for the average DFI (ADFI) did not change because of the missing DFI proportion and Loess correction. In terms of rank correlation and information criteria, Loess correction improved the accuracy of EBV for ADFI compared to randomly deleted cases. These findings indicate that the Loess equation is useful for correcting missing DFI values for individual pigs and that the correction of missing DFI values could be effective for the estimation of breeding values and genetic improvement using EBV for feeding traits. © 2017 The Authors. Animal Science Journal published by John Wiley & Sons Australia, Ltd on behalf of Japanese Society of Animal Science.

  1. Fair Value in the light of IFRS 13 «Fair Value Measurement»

    Directory of Open Access Journals (Sweden)

    V.V. Svitselska

    2015-03-01

    Full Text Available The main provisions of IFRS 13 «Fair Value Measurement» have been researched as well as its critical analysis has been conducted. Comparison of the previous and the new definition of the concept «fair value» has been done on the basis of what the shortcomings of the previous definition have been highlighted, the characteristic features and advantages of new definition from IFRS 13 «Fair Value Measurement» have been outlined. It has been proved that new interpretation of the concept of «fair value» is narrower and more accurate than the previous, it clarifies the subject matter, subjects of transactions, as well as the date of its execution. The scheme of estimation at fair value as well as model of fair value determination according to IFRS 13 «Fair Value Measurement» has been presented. Methods of measurement at fair value and the fair value hierarchy have been researched. Some disadvantages of provisions of IFRS 13 «Fair Value Measurement» on the basis of its analysis have been highlighted, uncertainty is essential among them in which fair value should be applied.

  2. Parameter Estimation of Inverter and Motor Model at Standstill using Measured Currents Only

    DEFF Research Database (Denmark)

    Rasmussen, Henrik; Knudsen, Morten; Tønnes, M.

    1996-01-01

    Methods for estimation of the parameters in the electrical equivalent diagram for the induction motor, based on special designed experiments, are given. In all experriments two of the three phases are given the same potential, i.e., no net torque is generatedand the motor is at standstill. Input...... and 3) the referred rotor rotor resistance and magnetizing inductance. The method developed in the two last experiments is independent of the inverter nonlinearity. New methods for system identification concerning saturation of the magnetic flux are given and a reference value for the flux level...... to the system is the reference values for the stator voltages given as duty cycles for the Pulse With Modulated power device. The system output is the measured stator currents. Three experiments are describedgiving respectively 1) the stator resistance and inverter parameters, 2) the stator transient inductance...

  3. Positive-Operator Valued Measure (POVM Quantization

    Directory of Open Access Journals (Sweden)

    Jean Pierre Gazeau

    2014-12-01

    Full Text Available We present a general formalism for giving a measure space paired with a separable Hilbert space a quantum version based on a normalized positive operator-valued measure. The latter are built from families of density operators labeled by points of the measure space. We especially focus on various probabilistic aspects of these constructions. Simple ormore elaborate examples illustrate the procedure: circle, two-sphere, plane and half-plane. Links with Positive-Operator Valued Measure (POVM quantum measurement and quantum statistical inference are sketched.

  4. Stride length: measuring its instantaneous value

    International Nuclear Information System (INIS)

    Campiglio, G C; Mazzeo, J R

    2007-01-01

    Human gait has been studied from different viewpoints: kinematics, dynamics, sensibility and others. Many of its characteristics still remain open to research, both for normal gait and for pathological gait. Objective measures of some of its most significant spatial/temporal parameters are important in this context. Stride length, one of these parameters, is defined as the distance between two consecutive contacts of one foot with ground. On this work we present a device designed to provide automatic measures of stride length. Its features make it particularly appropriate for the evaluation of pathological gait

  5. [South American camelids in Switzerland. II. Reference values for blood parameters].

    Science.gov (United States)

    Hengrave Burri, I; Tschudi, P; Martig, J; Liesegang, A; Meylan, M

    2005-08-01

    In order to establish reference values for blood parameters of South American camelids in Switzerland, 273 blood samples were collected from 141 llamas and 132 alpacas. These animals were classified in three categories (young animals blood cell count, white blood cell count, electrolytes, metabolites and enzymes). Significant differences between llamas and alpacas were evident for 26 parameters. This study also showed that differences between young animals, females and males must be taken into consideration. A comparison of blood values with the results of fecal analysis for parasite eggs showed that an infestation with Dicrocoelium dendriticum was associated with elevated activity of two liver enzymes (GLDH and gamma-GT) in the serum. In contrast, no differences were found in the results of blood analyses between animals shedding eggs of gastrointestinal strongyles or not.

  6. Polychronakos fractional statistics with a complex-valued parameter

    International Nuclear Information System (INIS)

    Rovenchak, Andrij

    2012-01-01

    A generalization of quantum statistics is proposed in a fashion similar to the suggestion of Polychronakos [Phys. Lett. B 365, 202 (1996)] with the parameter α varying between −1 (fermionic case) and +1 (bosonic case). However, unlike the original formulation, it is suggested that intermediate values are located on the unit circle in the complex plane. In doing so one can avoid the case α = 0 corresponding to the Boltzmann statistics, which is not a quantum one. The limits of α → +1 and α → −1 reproducing small deviations from the Bose and Fermi statistics, respectively, are studied in detail. The equivalence between the statistics parameter and a possible dissipative part of the excitation spectrum is established. The case of a non-conserving number of excitations is analyzed. It is defined from the condition that the real part of the chemical potential equals zero. Thermodynamic quantities of a model system of two-dimensional harmonic oscillators are calculated.

  7. Measurements of thermal parameters of solar modules

    International Nuclear Information System (INIS)

    Górecki, K; Krac, E

    2016-01-01

    In the paper the methods of measuring thermal parameters of photovoltaic panels - transient thermal impedance and the absorption factor of light-radiation are presented. The manner of realising these methods is described and the results of measurements of the considered thermal parameters of selected photovoltaic panels are presented. The influence of such selected factors as a type of the investigated panel and its mounting manner on transient thermal impedance of the considered panels is also discussed. (paper)

  8. Measuring Value in Internal Medicine Residency Training Hospitals Using Publicly Reported Measures.

    Science.gov (United States)

    Schickedanz, Adam; Gupta, Reshma; Arora, Vineet M; Braddock, Clarence H

    2018-03-01

    Graduate medical education (GME) lacks measures of resident preparation for high-quality, cost-conscious practice. The authors used publicly reported teaching hospital value measures to compare internal medicine residency programs on high-value care training and to validate these measures against program director perceptions of value. Program-level value training scores were constructed using Centers for Medicare & Medicaid Services Value-Based Purchasing (VBP) Program hospital quality and cost-efficiency data. Correlations with Association of Program Directors in Internal Medicine Annual Survey high-value care training measures were examined using logistic regression. For every point increase in program-level VBP score, residency directors were more likely to agree that GME programs have a responsibility to contain health care costs (adjusted odds ratio [aOR] 1.18, P = .04), their faculty model high-value care (aOR 1.07, P = .03), and residents are prepared to make high-value medical decisions (aOR 1.07, P = .09). Publicly reported clinical data offer valid measures of GME value training.

  9. Validity of a smartphone protractor to measure sagittal parameters in adult spinal deformity.

    Science.gov (United States)

    Kunkle, William Aaron; Madden, Michael; Potts, Shannon; Fogelson, Jeremy; Hershman, Stuart

    2017-10-01

    Smartphones have become an integral tool in the daily life of health-care professionals (Franko 2011). Their ease of use and wide availability often make smartphones the first tool surgeons use to perform measurements. This technique has been validated for certain orthopedic pathologies (Shaw 2012; Quek 2014; Milanese 2014; Milani 2014), but never to assess sagittal parameters in adult spinal deformity (ASD). This study was designed to assess the validity, reproducibility, precision, and efficiency of using a smartphone protractor application to measure sagittal parameters commonly measured in ASD assessment and surgical planning. This study aimed to (1) determine the validity of smartphone protractor applications, (2) determine the intra- and interobserver reliability of smartphone protractor applications when used to measure sagittal parameters in ASD, (3) determine the efficiency of using a smartphone protractor application to measure sagittal parameters, and (4) elucidate whether a physician's level of experience impacts the reliability or validity of using a smartphone protractor application to measure sagittal parameters in ASD. An experimental validation study was carried out. Thirty standard 36″ standing lateral radiographs were examined. Three separate measurements were performed using a marker and protractor; then at a separate time point, three separate measurements were performed using a smartphone protractor application for all 30 radiographs. The first 10 radiographs were then re-measured two more times, for a total of three measurements from both the smartphone protractor and marker and protractor. The parameters included lumbar lordosis, pelvic incidence, and pelvic tilt. Three raters performed all measurements-a junior level orthopedic resident, a senior level orthopedic resident, and a fellowship-trained spinal deformity surgeon. All data, including the time to perform the measurements, were recorded, and statistical analysis was performed to

  10. Intravoxel incoherent motion diffusion imaging of the liver: Optimal b-value subsampling and impact on parameter precision and reproducibility

    International Nuclear Information System (INIS)

    Dyvorne, Hadrien; Jajamovich, Guido; Kakite, Suguru; Kuehn, Bernd; Taouli, Bachir

    2014-01-01

    Highlights: • We assess the precision and reproducibility of liver IVIM diffusion parameters. • Liver IVIM DWI can be performed with 4 b-values with good parameter precision. • Liver IVIM DWI can be performed with 4 b-values with good parameter reproducibility. - Abstract: Purpose: To increase diffusion sampling efficiency in intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver by reducing the number of diffusion weightings (b-values). Materials and methods: In this IRB approved HIPAA compliant prospective study, 53 subjects (M/F 38/15, mean age 52 ± 13 y) underwent IVIM DWI at 1.5 T using 16 b-values (0–800 s/mm 2 ), with 14 subjects having repeat exams to assess IVIM parameter reproducibility. A biexponential diffusion model was used to quantify IVIM hepatic parameters (PF: perfusion fraction, D: true diffusion and D*: pseudo diffusion). All possible subsets of the 16 b-values were probed, with number of b values ranging from 4 to 15, and corresponding parameters were quantified for each subset. For each b-value subset, global parameter estimation error was computed against the parameters obtained with all 16 b-values and the subsets providing the lowest error were selected. Interscan estimation error was also evaluated between repeat exams to assess reproducibility of the IVIM technique in the liver. The optimal b-values distribution was selected such that the number of b-values was minimal while keeping parameter estimation error below interscan reproducibility error. Results: As the number of b-values decreased, the estimation error increased for all parameters, reflecting decreased precision of IVIM metrics. Using an optimal set of 4 b-values (0, 15, 150 and 800 s/mm 2 ), the errors were 6.5, 22.8 and 66.1% for D, PF and D* respectively. These values lie within the range of test–retest reproducibility for the corresponding parameters, with errors of 12.0, 32.3 and 193.8% for D, PF and D* respectively. Conclusion: A set

  11. The final measurements of the muon decay parameters from the TWIST experiment

    International Nuclear Information System (INIS)

    Bayes, R

    2013-01-01

    The TWIST (TRIUMF Weak Interaction Symmetry Test) experiment probes the Lorentz structure of the weak interaction using muon decay. This structure has a very well defined form under the Standard Model (SM) which makes precise predictions for the shape of the decay positron spectrum with respect to momentum and angle. The shape of the spectrum may be described under some rather general assumptions using a set of decay parameters whose values according to the SM are ρ = δ = 3/4, η = 0, and ξ = 1. TWIST uses a large sample of muon decays in a large acceptance spectrometer to measure the decay parameters to an order of magnitude greater precision than previous measurements. This experiment saw its last year of data collection in 2007. As TWIST is a systematics dominated experiment, much effort has been spent on refinements of the estimates of the systematic uncertainties over previous TWIST results. These proceedings will discuss the measures taken to achieve the precision goal of parts in 10 4 , and the physics implications of the experiment.

  12. Hematological parameters in relation to age, sex and biochemical values for mute swans (Cygnus olor).

    Science.gov (United States)

    Dolka, B; Włodarczyk, R; Zbikowski, A; Dolka, I; Szeleszczuk, P; Kluciński, W

    2014-06-01

    The knowledge of the correct morphological and biochemical parameters in mute swans is an important indicator of their health status, body condition, adaptation to habitat and useful diagnostic tools in veterinary practice and ecological research. The aim of the study was to obtain hematological parameters in relation to age, sex and serum biochemistry values in wild-living mute swans. We found the significant differences in the erythrocyte count, hematocrit, hemoglobin concentration and erythrocyte sedimentation rate in relation to age of mute swans. There were no differences in hematological values between males and females. The leukogram and H/L ratio did not vary by age and sex in swans. Among of biochemical parameters the slightly increased AST, ALP, CK, K, urea, decreased CHOL and TG values were recorded. As far as we know, this is the first study in which the morphometric parameters of blood cells in mute swans were presented. We found extremely low concentration of lead in blood (at subthreshold level). No blood parasites were found in blood smears. The analysis of body mass and biometric parameters revealed a significant differences dependent on age and sex. No differences in the scaled mass index were found. Our results represent a normal hematologic and blood chemistry values and age-sex related changes, as reference values for the mute swan.

  13. Recommended Parameter Values for GENII Modeling of Radionuclides in Routine Air and Water Releases

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, Sandra F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Arimescu, Carmen [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Napier, Bruce A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hay, Tristan R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2012-11-01

    The GENII v2 code is used to estimate dose to individuals or populations from the release of radioactive materials into air or water. Numerous parameter values are required for input into this code. User-defined parameters cover the spectrum from chemical data, meteorological data, agricultural data, and behavioral data. This document is a summary of parameter values that reflect conditions in the United States. Reasonable regional and age-dependent data is summarized. Data availability and quality varies. The set of parameters described address scenarios for chronic air emissions or chronic releases to public waterways. Considerations for the special tritium and carbon-14 models are briefly addressed. GENIIv2.10.0 is the current software version that this document supports.

  14. English Value-Added Measures: Examining the Limitations of School Performance Measurement

    Science.gov (United States)

    Perry, Thomas

    2016-01-01

    Value-added "Progress" measures are to be introduced for all English schools in 2016 as "headline" measures of school performance. This move comes despite research highlighting high levels of instability in value-added measures and concerns about the omission of contextual variables in the planned measure. This article studies…

  15. A measurement of the resonance parameters of the neutral intermediate vector boson

    International Nuclear Information System (INIS)

    Nash, J.A.

    1990-01-01

    This thesis presents a measurement of the Z 0 Boson resonance parameters. The measurement was performed at the Stanford Linear Collider using the Mark II detector. Based on a sample of 480 Hadronic and Leptonic decays, the mass is found to be 91.14 ± 0.12 GeV/c 2 , the total width is 2.42 -0.35 +0.45 GeV, and the peak cross section for all Hadronic events, and for Muon and Tau events with cosθ Thrust < 0. 65 is 45 ± 4 nb. By constraining the visible width to the Standard Model value for 5 quarks and 3 charged leptons, and allowing the invisible width to be a parameter, the width to invisible decay modes is found to be 0.46 ± 0.10 GeV. Assuming this width comes from massless neutrinos, this measurement corresponds to 2.8 ± 0.6 neutrino species. This measurement sets an upper limit of 3.9 neutrino generations at the 95% confidence level, ruling out a fourth generation of Standard Model neutrinos at this level. 54 refs., 65 figs., 11 tabs

  16. Quantum measurement with a positive operator-valued measure

    International Nuclear Information System (INIS)

    Brandt, Howard E

    2003-01-01

    In the quantum theory of measurement, the positive operator-valued measure (POVM) is an important concept, and its implementation can be useful. A POVM consists of a set of non-negative quantum-mechanical Hermitian operators that add up to the identity. The probability that a quantum system is in a particular state is given by the expectation value of the POVM operator corresponding to that state. Following a brief review of the mathematics and mention of the history of POVMs in quantum theory, a particular implementation of a POVM for use in the measurement of nonorthogonal photon polarization states is reviewed. The implementation consists simply of a Wollaston prism, a mirror, two beam splitters, a polarization rotator and three phototubes arranged in an interferometric configuration, and it is shown analytically that the device faithfully represents the POVM. Based on Neumark's extension theorem, the two-dimensional Hilbert space of the POVM implementation can be embedded in the three-dimensional Hilbert space of an ordinary projective-valued measure. Also, analytical expressions are given for the maximum Renyi information loss from the device to a disturbing probe, and for the error and inconclusive rates induced by the probe. Various aspects of the problem of probe optimization are elaborated

  17. Measurement of reactor parameters of the 'Nora' reactor by noise analysis method - power spectral density

    International Nuclear Information System (INIS)

    Jovanovic, S.; Stormark, E.

    1966-01-01

    Measurements of reactor parameters the Nora reactor by Power Spectral Density (PSD) method are described. In case of critical reactor this method was applied for direct measurement of β/l ratio, β is the effective yield of delayed neutrons and l is the neutron lifetime. In case of subcritical reactor values of α+β-ρ/l were measured, ρ is the negative reactivity. Out coming PSD was measured by a filter or by ISAC. PSD was registered by ISAC as well as the auto-correlation function [sr

  18. Parameter values for the long-term nuclear waste management food chain model LIMCAL

    International Nuclear Information System (INIS)

    Zach, Reto.

    1982-09-01

    Eighteen parameters of LIMCAL, a comprehensive food chain model for predicting ICRP 26 50-year committed effective dose equivalents to man due to long-term nuclear waste management are reviewed. The parameters are: soil bulk density, plowlayer depth, soil surface layer depth, resusupension factor, atmospheric dust load, deposition velocity, plant interception fraction, plant environmental half-time, translocation factor, time of above-ground exposure, plant yield, holdup time, animals' feed consumption rate, animals' water consumption rate, man's water consumption rate, food type calorie conversion factors, man's total caloric intake rate and food type calorie fractions. LIMCAL has both traditional and unique parameters. The former occur in most of the currently used assessment models for nuclear installations, whereas the latter do not. For each of the parameters of LIMCAL, a suitable generic value for long-term nuclear waste management was determined. Thus, the general literature and the values currently used or recommended by various agencies were reviewed

  19. FAIR VALUE MEASUREMENT UNDER IFRS 13

    Directory of Open Access Journals (Sweden)

    COZMA IGHIAN DIANA

    2015-07-01

    Full Text Available The IFRS 13, „Fair Value Measurement”, was first published in May 2011 and it applies to annual reporting periods that begin on or after January 1st 2013; this standard comes as a result of shared efforts on the part of the IASB and the FASB to develop a convergent framework regarding fair value measurement. The main purpose of this paper is to describe the main provisions of the IFRS 13 regarding fair value measurement, with a special emphasis on key concepts found throughout the standard, which refer to the principal market, the most advantageous market, the highest and best use, valuation techniques, and value hierarchy.

  20. Determination of K shell absorption jump factors and jump ratios of 3d transition metals by measuring K shell fluorescence parameters

    International Nuclear Information System (INIS)

    Kaçal, Mustafa Recep; Han, İbrahim; Akman, Ferdi

    2015-01-01

    Energy dispersive X-ray fluorescence technique (EDXRF) has been employed for measuring K-shell absorption jump factors and jump ratios for Ti, Cr, Fe, Co, Ni and Cu elements. The jump factors and jump ratios for these elements were determined by measuring K shell fluorescence parameters such as the Kα X-ray production cross-sections, K shell fluorescence yields, Kβ-to-Kα X-rays intensity ratios, total atomic absorption cross sections and mass attenuation coefficients. The measurements were performed using a Cd-109 radioactive point source and an Si(Li) detector in direct excitation and transmission experimental geometry. The measured values for jump factors and jump ratios were compared with theoretically calculated and the ones available in the literature. - Highlights: • This work regard the K shell absorption jump ratios and jump factors of Ti, Cr, Fe, Co, Ni and Cu. • This paper presents the first measurement of these parameters using the experimental K shell fluorescence parameters. • A good agreement was found between experimental and theoretical values. • The EDXRF technique was suitable, precise and reliable for the measurement of these atomic parameters

  1. Task completion report for investigating why output signal-variable values differ from their output component-parameter values in test problem MST2

    International Nuclear Information System (INIS)

    Steinke, R.G.

    1997-01-01

    Signal-variable values and their component-parameter values differ in an end-of-timestep edit to the TRCOUT and TRCGRF files because signal variables have beginning-of-timestep values, and component parameters have end-of-timestep values. Oscillatory divergence in the MST2 standard test problem after 9000 s occurs because of TRAC-P's numerical evaluation at a 1000 material Courant number. The magnitude of that divergence has diminished by a factor of 3.5 from Version 5.3.01 to 5.4.15 and by a factor of 25 from Version 5.4.15 to 5.4.28. That divergence can be eliminated by evaluating MST2 with a maximum material Courant number of 500

  2. New parameters and reference values for monitoring iron status in Middle Eastern adolescent male athletes.

    Science.gov (United States)

    Voss, S C; Varamenti, E; Elzain Elgingo, M; Bourdon, P C

    2014-04-01

    Hematological and biochemical parameters of 160 Middle Eastern adolescent male athletes (aged from 12-18 years) were tested in order to investigate their iron status and to establish reference values for this population. A focus of this study was also the investigation of Reticulocyte hemoglobin (RetHe) and soluble transferrin receptor (sTfR). Complete blood count, reticulocyte and sera parameters were analyzed at the beginning of the training season for these adolescent athletes. As the diagnosis of iron deficiency in adolescents is extremely difficult subjects were subdivided in three age groups (12-13, 14-15, 16-18). For most of the parameters our results confirmed the existing reference values reported in young athletes. Exceptions were however found with lower Mean Cell Volumes (79.9±4.3 fl) in this group when compared to other age matched data. RetHe, ferritin and sTfR levels were monitored for the interpretation of the iron status in this population and reference values for these parameters were also established. Information to help evidence based decision making about the need for supplementation or further investigations is provided to physicians and nutritionists. RetHe with a proposed threshold value of 25 pg expands the list of parameters which can be used to monitor athletes.

  3. Measurement and simulation of the TRR BNCT beam parameters

    Energy Technology Data Exchange (ETDEWEB)

    Bavarnegin, Elham [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Department of Physics, University of Guilan, Rasht (Iran, Islamic Republic of); Sadremomtaz, Alireza [Department of Physics, University of Guilan, Rasht (Iran, Islamic Republic of); Khalafi, Hossein [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Kasesaz, Yaser, E-mail: ykasesaz@aeoi.org.ir [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Golshanian, Mohadeseh; Ghods, Hossein; Ezzati, Arsalan; Keyvani, Mehdi; Haddadi, Mohammad [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of)

    2016-09-11

    Recently, the configuration of the Tehran Research Reactor (TRR) thermal column has been modified and a proper thermal neutron beam for preclinical Boron Neutron Capture Therapy (BNCT) has been obtained. In this study, simulations and experimental measurements have been carried out to identify the BNCT beam parameters including the beam uniformity, the distribution of the thermal neutron dose, boron dose, gamma dose in a phantom and also the Therapeutic Gain (TG). To do this, the entire TRR structure including the reactor core, pool, the thermal column and beam tubes have been modeled using MCNPX Monte Carlo code. To measure in-phantom dose distribution a special head phantom has been constructed and foil activation techniques and TLD700 dosimeter have been used. The results show that there is enough uniformity in TRR thermal BNCT beam. TG parameter has the maximum value of 5.7 at the depth of 1 cm from the surface of the phantom, confirming that TRR thermal neutron beam has potential for being used in treatment of superficial brain tumors. For the purpose of a clinical trial, more modifications need to be done at the reactor, as, for example design, and construction of a treatment room at the beam exit which is our plan for future. To date, this beam is usable for biological studies and animal trials. There is a relatively good agreement between simulation and measurement especially within a diameter of 10 cm which is the dimension of usual BNCT beam ports. This relatively good agreement enables a more precise prediction of the irradiation conditions needed for future experiments.

  4. Identification of grid model parameters using synchrophasor measurements

    Energy Technology Data Exchange (ETDEWEB)

    Boicea, Valentin; Albu, Mihaela [Politehnica University of Bucharest (Romania)

    2012-07-01

    Presently a critical element of the energy networks is represented by the active distribution grids, where generation intermittency and controllable loads contribute to a stochastic varability of the quantities characterizing the grid operation. The capability of controlling the electrical energy transfer is also limited by the incomplete knowledge of the detailed electrical model of each of the grid components. Asset management in distribution grids has to consider dynamic loads, while high loading of network sections might already have degraded some of the assets. Moreover, in case of functional microgrids, all elements need to be modelled accurately and an appropriate measurement layer enabling online control needs to be deployed. In this paper a method for online identification of the actual parameter values in grid electrical models is proposed. Laboratory results validating the proposed method are presented. (orig.)

  5. VALUATION TECHNIQUES USED IN FAIR VALUE MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Cristina-Aurora, BUNEA-BONTAS

    2013-12-01

    Full Text Available Valuation of assets and liabilities involves significant judgements and estimates, especially when fair value measurement is required. Currently, IFRS 13 Fair Value Measurement offers a single and more comprehensive source of guidance that is applied to almost all fair value estimates. When measuring fair value of fixed assets, intangible assets, specified financial assets or liabilities, different valuation techniques may be used: the market approach, the cost approach and the income approach. This article reviews these techniques and points out that different valuation practices may provide different results depending on the item being fair valued and on the inputs used. Also it emphasizes that, in particular circumstances, there is the possibility that a certain technique may be more appropriate than other.

  6. Uniqueness of Gibbs measure for Potts model with countable set of spin values

    International Nuclear Information System (INIS)

    Ganikhodjaev, N.N.; Rozikov, U.A.

    2004-11-01

    We consider a nearest-neighbor Potts model with countable spin values 0,1,..., and non zero external field, on a Cayley tree of order k (with k+1 neighbors). We study translation-invariant 'splitting' Gibbs measures. We reduce the problem to the description of the solutions of some infinite system of equations. For any k≥1 and any fixed probability measure ν with ν(i)>0 on the set of all non negative integer numbers Φ={0,1,...} we show that the set of translation-invariant splitting Gibbs measures contains at most one point, independently on parameters of the Potts model with countable set of spin values on Cayley tree. Also we give a full description of the class of measures ν on Φ such that wit respect to each element of this class our infinite system of equations has unique solution {a i =1,2,...}, where a is an element of (0,1). (author)

  7. Measuring the value of intangibles

    DEFF Research Database (Denmark)

    Clausen, Saskia; Hirth, Stefan

    2016-01-01

    We propose a new earnings-based measure for the value of intangibles. To validate this measure, we compare it to commonly used proxies for intangible intensity, such as R&D expenses. While R&D expenses measure the investment in new intangibles, our new measure gauges the productivity of already e...... of our intangible-intensity measure in the context of capital structure. We find that more intangible-intensive firms have lower leverage. © 2016 Elsevier B.V....

  8. The method of extraction of subspectra with appreciably different values of hyperfine interaction parameters from Moessbauer spectra

    International Nuclear Information System (INIS)

    Nemtsova, O.M.

    2006-01-01

    The task of Moessbauer spectra processing of complex locally inhomogeneous or multi-phase systems is to reveal subspectral contributions with appreciably different values of hyperfine interaction parameters (HFI) in them. A universal method of processing such spectra is suggested which allows to extract the probability density distribution (PDD) of HFI parameters corresponding to the subspectra with essentially different parameters values. The basis of the method is Tikhonov's regularization method with selection for each subspectrum its own value of the regularization parameter. The universal application of the method is demonstrated in the examples of processing real spectra with different sets of subspectral contributions

  9. An alternative approach to absolute-value test for the parameters of ...

    African Journals Online (AJOL)

    An alternative approach to absolute-value test statistic Mn is developed for conducting tests simultaneously on all the parameters of multiple linear regression models. Under certain null and alternative hypotheses, the new test statistic is shown to have limiting central and noncentral chisquare distributions, respectively.

  10. Selection of noise parameters for Kalman filter

    Institute of Scientific and Technical Information of China (English)

    Ka-Veng Yuen; Ka-In Hoi; Kai-Meng Mok

    2007-01-01

    The Bayesian probabilistic approach is proposed to estimate the process noise and measurement noise parameters for a Kalman filter. With state vectors and covariance matrices estimated by the Kalman filter, the likehood of the measurements can be constructed as a function of the process noise and measurement noise parameters. By maximizing the likklihood function with respect to these noise parameters, the optimal values can be obtained. Furthermore, the Bayesian probabilistic approach allows the associated uncertainty to be quantified. Examples using a single-degree-of-freedom system and a ten-story building illustrate the proposed method. The effect on the performance of the Kalman filter due to the selection of the process noise and measurement noise parameters was demonstrated. The optimal values of the noise parameters were found to be close to the actual values in the sense that the actual parameters were in the region with significant probability density. Through these examples, the Bayesian approach was shown to have the capability to provide accurate estimates of the noise parameters of the Kalman filter, and hence for state estimation.

  11. Method of integral values for measuring the heat conductivity and other parameter of materials up to temperatures of 2000 Kelvin; Integralwertverfahren zur Messung der Waermeleiffaehigkeit und anderer Stoffwerte bis zu Temperaturen von 2000 Kelvin

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, Manfred

    1974-06-15

    For the development of new reactor materials and nuclear fuels, it is important to measure the heat conductivity of the materials up to high temperatures. Performing the measurements several difficulties arise. A method which avoids most of the measuring problems has been developed and used to measure the heat conductivity of graphite and uranium carbonidrides. The method is based on measuring a set of integral values of the heat conductivity over relatively large temperature intervals and on evaluating the temperature curve of the heat conductivity by a computer program. Further parameters of the materials as electrical conductivity and thermal expansion can be measured simultaneously.

  12. Application of extreme value distribution function in the determination of standard meteorological parameters for nuclear power plants

    International Nuclear Information System (INIS)

    Jiang Haimei; Liu Xinjian; Qiu Lin; Li Fengju

    2014-01-01

    Based on the meteorological data from weather stations around several domestic nuclear power plants, the statistical results of extreme minimum temperatures, minimum. central pressures of tropical cyclones and some other parameters are calculated using extreme value I distribution function (EV- I), generalized extreme value distribution function (GEV) and generalized Pareto distribution function (GP), respectively. The influence of different distribution functions and parameter solution methods on the statistical results of extreme values is investigated. Results indicate that generalized extreme value function has better applicability than the other two distribution functions in the determination of standard meteorological parameters for nuclear power plants. (authors)

  13. A National Trial on Differences in Cerebral Perfusion Pressure Values by Measurement Location.

    Science.gov (United States)

    McNett, Molly M; Bader, Mary Kay; Livesay, Sarah; Yeager, Susan; Moran, Cristina; Barnes, Arianna; Harrison, Kimberly R; Olson, DaiWai M

    2018-04-01

    Cerebral perfusion pressure (CPP) is a key parameter in management of brain injury with suspected impaired cerebral autoregulation. CPP is calculated by subtracting intracranial pressure (ICP) from mean arterial pressure (MAP). Despite consensus on importance of CPP monitoring, substantial variations exist on anatomical reference points used to measure arterial MAP when calculating CPP. This study aimed to identify differences in CPP values based on measurement location when using phlebostatic axis (PA) or tragus (Tg) as anatomical reference points. The secondary study aim was to determine impact of differences on patient outcomes at discharge. This was a prospective, repeated measures, multi-site national trial. Adult ICU patients with neurological injury necessitating ICP and CPP monitoring were consecutively enrolled from seven sites. Daily MAP/ICP/CPP values were gathered with the arterial transducer at the PA, followed by the Tg as anatomical reference points. A total of 136 subjects were enrolled, resulting in 324 paired observations. There were significant differences for CPP when comparing values obtained at PA and Tg reference points (p Differences remained significant in repeated measures model when controlling for clinical factors (mean CPP-PA = 80.77, mean CPP-Tg = 70.61, p identified as adequate with PA values, yet inadequate with CPP values measured at the Tg. Findings identify numerical differences for CPP based on anatomical reference location and highlight importance of a standard reference point for both clinical practice and future trials to limit practice variations and heterogeneity of findings.

  14. Application of a virtual coordinate measuring machine for measurement uncertainty estimation of aspherical lens parameters

    International Nuclear Information System (INIS)

    Küng, Alain; Meli, Felix; Nicolet, Anaïs; Thalmann, Rudolf

    2014-01-01

    Tactile ultra-precise coordinate measuring machines (CMMs) are very attractive for accurately measuring optical components with high slopes, such as aspheres. The METAS µ-CMM, which exhibits a single point measurement repeatability of a few nanometres, is routinely used for measurement services of microparts, including optical lenses. However, estimating the measurement uncertainty is very demanding. Because of the many combined influencing factors, an analytic determination of the uncertainty of parameters that are obtained by numerical fitting of the measured surface points is almost impossible. The application of numerical simulation (Monte Carlo methods) using a parametric fitting algorithm coupled with a virtual CMM based on a realistic model of the machine errors offers an ideal solution to this complex problem: to each measurement data point, a simulated measurement variation calculated from the numerical model of the METAS µ-CMM is added. Repeated several hundred times, these virtual measurements deliver the statistical data for calculating the probability density function, and thus the measurement uncertainty for each parameter. Additionally, the eventual cross-correlation between parameters can be analyzed. This method can be applied for the calibration and uncertainty estimation of any parameter of the equation representing a geometric element. In this article, we present the numerical simulation model of the METAS µ-CMM and the application of a Monte Carlo method for the uncertainty estimation of measured asphere parameters. (paper)

  15. Repeatability and Comparison of Keratometry Values Measured with Potec PRK-6000 Autorefractometer, IOLMaster, and Pentacam

    Directory of Open Access Journals (Sweden)

    Adem Türk

    2014-05-01

    Full Text Available Objectives: To research the repeatability and intercompatibility of keratometry values measured with Potec PRK-6000 autorefractometer, IOL Master, and Pentacam. Materials and Methods: In this prospective study, consecutive measurements were performed in two different sessions with the mentioned three devices on 110 eyes of 55 subjects who had no additional ocular pathology except for refraction error. The consistency of flat and steep keratometry, average keratometry, and corneal astigmatism values obtained in both sessions was compared by using intraclass correlation coefficient (ICC. The measurement differences between the devices were statistically compared as well. Results: The mean age of the study subjects was 23.05±3.01 (18-30 years. ICC values of average keratometry measurements obtained in the sessions were 0.996 for Potec PRK-6000 autorefractometer, 0.997 for IOL Master, and 0.999 for Pentacam. There was high compatibility between the three devices in terms of average keratometry values in Bland-Altman analysis. However, there were statistically significant differences between the devices in terms of parameters other than corneal astigmatism. Conclusion: The repeatability of the three devices was found considerably high in keratometry measurements. However, it is not appropriate for these devices to be substituted for each other in keratometry measurements. (Turk J Ophthalmol 2014; 44: 179-83

  16. Parameter values for the Heysham site for use in the CODAR2 program

    International Nuclear Information System (INIS)

    Maul, P.R.

    1985-03-01

    Details are given of parameter values relevant to the Heysham site for the calculation of individual and collective radiation exposure arising from routine discharges of liquid effluent to the sea. These parameters are to be used in the CODAR2 computer program, and the approach taken in their specification is the same as that employed previously for the Sizewell site. (author)

  17. Measurement of np elastic scattering spin-spin correlation parameters at 484, 634, and 788 MeV

    International Nuclear Information System (INIS)

    Garnett, R.W.

    1989-03-01

    The spin-spin correlation parameters C/sub LL/ and C/sub SL/ were measured for np elastic scattering at the incident neutron kinetic energy of 634 MeV. Good agreement was obtained with previously measured data. Additionally, the first measurement of the correlation parameter C/sub SS/ was made at the three energies, 484, 634, and 788 MeV. It was found that the new values, in general, do not agree well with phase shift predictions. A study was carried out to determine which of the isospin-0 partial waves will be affected by this new data. It was found that the 1 P 1 partial wave will be affected significantly at all three measurement energies. At 634 and 788 MeV, the 3 S 1 phase shifts will also change. 29 refs., 21 figs., 16 tabs

  18. Evaluation of the Effects of Menstrual Cycle on Anterior Chamber Parameters as Measured with Pentacam

    Directory of Open Access Journals (Sweden)

    Arzu Seyhan Karatepe

    2013-01-01

    Full Text Available Pur po se: To evaluate the effects of endogenous gonadotropic hormones (follicle-stimulating hormone, luteinizing hormone and sex steroids (progesterone, estrogen to anterior segment parameters. Ma te ri al and Met hod: Thirty healthy females who had a menstrual cycle of 28±1 day and with a mean age of 36.5±7.56 (range, 20 – 46 years were included in the study. Starting from the first day of their cycle, Pentacam Scheimpflug camera measurements were performed on the 1st, 3rd, 7th, 12th, 16th, 21st, 26th, and 28th days. The central corneal thickness, anterior chamber depth, anterior segment volume, keratometric values, anterior chamber angle value, and pupilla diameter of both eyes were evaluated. Repeated measures analysis of variance test was used for statistical analysis. Re sults: No difference that reaches statistical significance was found in the means of central corneal thickness, anterior chamber volume, keratometric values, anterior chamber angle, and pupilla diameter between the days. Mean anterior chamber depth measurement of the right eyes on the 1st day was 2.72±0.44 mm, whereas it was 2.77±0.46 mm on the 26th day. Mean anterior chamber depth measurement of the left eyes on the 1st day was 2.74±0.42 mm, whereas it was 2.80±0.43 mm on the 26th day. This increment of anterior chamber depth value from the 1st to the 26th days was found to be statistically significant (p≤0.05. Dis cus si on: Progesterone and estrogen that rise in the second half of the menstrual cycle might have a deepening effect on the anterior chamber. These findings should be further investigated with more profound studies that also evaluate the hormonal values and their correlations with anterior segment parameters. (Turk J Ophthalmol 2013; 43: 15-8

  19. Corporate performance and the measures of value added

    Directory of Open Access Journals (Sweden)

    T. Petravičius

    2008-09-01

    Full Text Available In recent years, managers have turned their attention to the ways increasing the value of their companies. A number of competing measures have been developed and marketed by investment and consulting firms. This paper considers the ways in which value can be created or destroyed in a firm and looks at how to calculate the cost of capital used to measure the opportunity cost of investing funds in one particular business instead of others with equivalent risk. Next, we have a look at the four most widely used value enhancement measures including Economic Value Added, Cash Flow Return on Investment, Market Value Added, Cash Value Added and use an example to think of where these approaches yield similar results and where differences might occur. In conclusion, we summarize the new or unique points in these competing measures, establish the information they can give and explain how to use it when managing and creating shareholder value.

  20. Measurement of specific parameters for dose calculation after inhalation of aerols containing transuranium elements

    International Nuclear Information System (INIS)

    Ramounet-le Gall, B.; Fritsch, P.; Abram, M.C.; Rateau, G.; Grillon, G.; Guillet, K.; Baude, S.; Berard, P.; Ansoborlo, E.; Delforge, J.

    2002-01-01

    A review on specific parameter measurements to calculate doses per unit of incorporation according to recommendations of the International Commission of Radiological Protection has been performed for inhaled actinide oxides. Alpha activity distribution of the particles can be obtained by autoradiography analysis using aerosol sampling filters at the work places. This allows us to characterize granulometric parameters of 'pure' actinide oxides, but complementary analysis by scanning electron microscopy is needed for complex aerosols. Dissolution parameters with their standard deviation are obtained after rat inhalation exposure, taking into account both mechanical lung clearance and actinide transfer to the blood estimated from bone retention. In vitro experiments suggest that the slow dissolution rate might decrease as a function of time following exposure. Dose calculation software packages have been developed to take into account granulometry and dissolution parameters as well as specific physiological parameters of exposed individuals. In the case of poorly soluble actinide oxides, granulometry and physiology appear as the main parameters controlling dose value, whereas dissolution only alters dose distribution. Validation of these software packages are in progress. (author)

  1. Equivalent circuit parameters of nickel/metal hydride batteries from sparse impedance measurements

    Science.gov (United States)

    Nelatury, Sudarshan Rao; Singh, Pritpal

    In a recent communication, a method for extracting the equivalent circuit parameters of a lead acid battery from sparse (only three) impedance spectroscopy observations at three different frequencies was proposed. It was based on an equivalent circuit consisting of a bulk resistance, a reaction resistance and a constant phase element (CPE). Such a circuit is a very appropriate model of a lead-acid cell at high state of charge (SOC). This paper is a sequel to it and presents an application of it in case of nickel/metal hydride (Ni/MH) batteries, which also at high SOC are represented by the same circuit configuration. But when the SOC of a Ni/MH battery under interrogation goes low, The EIS curve has a positive slope at the low frequency end and our technique yields complex values for the otherwise real circuit parameters, suggesting the need for additional elements in the equivalent circuit and a definite relationship between parameter consistency and SOC. To improvise the previous algorithm, in order that it works reasonably well at both high and low SOCs, we propose three more measurements—two at very low frequencies to include the Warburg response and one at a high frequency to model the series inductance, in addition to the three in the mid frequency band—totally six measurements. In most of the today's instrumentation, it is the user who should choose the circuit configuration and the number of frequencies where impedance should be measured and the accompanying software performs data fitting by complex nonlinear least squares. The proposed method has built into it an SOC-based decision-making capability—both to choose the circuit configuration and to estimate the values of the circuit elements.

  2. Rocket measurements within a polar cap arc: Plasma, particle, and electric circuit parameters

    International Nuclear Information System (INIS)

    Weber, E.J.; Ballenthin, J.O.; Basu, S.; Carlson, H.C.; Hardy, D.A.; Maynard, N.C.; Smiddy, M.; Kelley, M.C.; Fleischman, J.R.; Sheehan, R.E.; Pfaff, R.F.; Rodriguez, P.

    1989-01-01

    An instrumented rocket payload was launched into a polar cap F layer aurora to investigate the energetic particle, plasma, and electric circuit parameters of a Sun-aligned arc. On-board instruments measured energetic electron flux, ion composition and density fluctuations, electron density and temperature, electron density fluctuations, and ac and dc electric fields. Real-time all-sky imaging photometer measurements of the location and motion of the aurora, were used to determine the proper geophysical situation for launch. Comparison of the in situ measurements with remote optical measurements shows that the arc was produced by fluxes of low-energy (< 1 keV) electrons. Field-aligned potentials in the arc inferred from the electron spectra had a maximum value of approximately 300 V, and from the spectral shape a parent population of preaccelerated electrons characteristic of the boundary plasma sheet or magnetosheath was inferred. Electric field components along and across the arc show sunward flow within the arc and duskward drift of the arc consistent with the drift direction and speed determined from optical imaging. Thus this arc is drifting duskward under the influence of the convection electric field. Three possible explanations for this (field-aligned currents, chemistry, and transport) are considered. Finally, ionospheric irregularity and electric field fluctuations indicate two different generation mechanisms on the dawnside and duskside of the arc. On the duskside, parameters are suggestive of an interchange process, while on the dawnside, fluctuation parameters are consistent with a velocity shear instability

  3. Measuring value sensitivity in medicine.

    Science.gov (United States)

    Ineichen, Christian; Christen, Markus; Tanner, Carmen

    2017-01-28

    Value sensitivity - the ability to recognize value-related issues when they arise in practice - is an indispensable competence for medical practitioners to enter decision-making processes related to ethical questions. However, the psychological competence of value sensitivity is seldom an explicit subject in the training of medical professionals. In this contribution, we outline the traditional concept of moral sensitivity in medicine and its revised form conceptualized as value sensitivity and we propose an instrument that measures value sensitivity. We developed an instrument for assessing the sensitivity for three value groups (moral-related values, values related to the principles of biomedical ethics, strategy-related values) in a four step procedure: 1) value identification (n = 317); 2) value representation (n = 317); 3) vignette construction and quality evaluation (n = 37); and 4) instrument validation by comparing nursing professionals with hospital managers (n = 48). We find that nursing professionals recognize and ascribe importance to principle-related issues more than professionals from hospital management. The latter are more likely to recognize and ascribe importance to strategy-related issues. These hypothesis-driven results demonstrate the discriminatory power of our newly developed instrument, which makes it useful not only for health care professionals in practice but for students and people working in the clinical context as well.

  4. Equipment for the measurement of non-electrical parameters

    International Nuclear Information System (INIS)

    Lewin, M.I.; Ewtuchow, A.N.

    1977-01-01

    The invention concerns equipment for the measurement of non-electrical parameters, which can be used in data processing and control equipment. The transducer converts non-electrical parameters into electrical signals. The process according to the invention is explained using the example of an inductive transducer, which is fed with alternating current. The measured parameter affects the mutual inductance of the transducer, so that the secondary voltage supplied by it is a function of the measured parameter. Amplitude measurement of this voltage by means of rectification and filtering has the disadvantage of long time constants, where the measuring period would amount to 6 to 10 cycles of the supply voltage. According to the invention the secondary voltage of the transducer is connected to an integrator during a half-cycle between two zeros, which charges a capacitor to a voltage proportional to the amplitude. An analogue-digital converter now produces a digital signal corresponding to the capacitor voltage, which is taken to the control equipment. This conversion occurs during a fraction of the second half-cycle, so that there is still time before the end of this half-cycle, so that there is still time before the end of this half-cycle to discharge the capacitor and to reproduce the initial conditions. In the next cycle the whole process is repeated, so that the measuring process only takes one cycle. In order to make the digital signal independent of the amplitude of the current fed in, this also flows through an identical transducer with constant mutual inductance, and affects the analogue-digital converter via a comparative circuit. (ORU) [de

  5. The Vocal Extent Measure: Development of a Novel Parameter in Voice Diagnostics and Initial Clinical Experience

    Directory of Open Access Journals (Sweden)

    Philipp P. Caffier

    2018-01-01

    Full Text Available Voice range profile (VRP and evaluation using the dysphonia severity index (DSI represent essentials of instrument-based objective voice diagnostics and are implemented in different standardized registration programs. The respective measurement results, however, show differences. The aim of the study was to prove these differences statistically and to develop a new parameter, the Vocal Extent Measure (VEM, which is not influenced by the measurement program. VRPs of 97 subjects were recorded by two examiners using the established registration programs DiVAS (XION medical and LingWAVES (WEVOSYS simultaneously. The VEM was developed on the basis of VRP area and perimeter. All 194 VRP files were analyzed for various parameters and gender independence. The registration programs exhibited significant differences in several vocal parameters. A significant gender influence for DSI was found with DiVAS (p<0.01, but not with LingWAVES. The VEM quantified the dynamic performance and frequency range by a unidimensional, interval-scaled value without unit, mostly between 0 and 120. This novel parameter represents an intelligible and user-friendly positive measure of vocal function, allows simple and stable VRP description, and seems to be suitable for quantification of vocal capacity. In contrast to DSI, the VEM proved to be less susceptible to registration program and gender.

  6. Influence of puerperal gonadoreline application on reproductive parameter values in cows

    Directory of Open Access Journals (Sweden)

    Šabanović Mustafa

    2006-01-01

    Full Text Available This paper presents results of investigations conducted in order to investigate the influence of gonadoreline application 14-16, 17-20 and 21-25 days postpartum on reproductive parameters values in cows. A total of 241 cows was included in the study. Out of this number, 126 cows were treated with gonadoreline while 115 animals were placebo treated and served as controls. The estimation of progesterone concentration was conducted on 43 animals selected randomly from the first two groups of treated cows. Analyses of the results in cows that gave normal birth, revealed that mean anoestrus period, open day's period and intervals between calving were significantly lower in the gonadoreline treated groups. Reproductive parameter values in cows with different progesterone concentrations did not differ significantly. The period from gonadoreline application until conception, was shorter by 30, 30 and 14 days, respectively, compared to the controls. The total conception rate from the first three artificial inseminations was 88. 8% in gonadoreline treated groups and 83.47 % in the control groups.

  7. Moderating ratio parameter evaluation for different materials by means of Monte Carlo calculations and reactivity direct measurements

    International Nuclear Information System (INIS)

    Borio, A.; Cagnazzo, M.; Marchetti, F.; Pappalardo, P.; Salvini, A.

    2004-01-01

    The aim of this work is to determine moderating properties of different materials (water, graphite, perfluoropolyethers), in particular the slowing down power (SDP) and the moderating ratio (MR), defined as SDP =ξΣ S and MR=ξΣ S /Σ A , where Σ S and Σ A represent the macroscopic scattering and absorption cross section, respectively, and ξ is the average logarithmic energy loss per collision. Slowing-down power indicates how rapidly a neutron will slow down in the material, but it does not fully explain the effectiveness of the material as a moderator. In fact, a material can slow down neutrons with high efficiency because of its big Σ S , but it can be a poor moderator because with high probability it also absorbs neutrons. Thus, the most complete measure of the effectiveness of a moderator is the moderating ratio parameter which takes into account also the absorption effects: the bigger is the moderating ratio values, the more effectively the material performs as a moderator. The first part of the work consisted in the comparison between the SDP and MR parameter evaluated for different materials by means of Monte Carlo simulations and by means of calculations based on their definition formula (they are developed from knowledge of material composition and of microscopic cross section σ i (derived from literature)). It was found that this comparison showed a good agreement with errors less than 10 %. Thus the Monte Carlo code seems to be a good support for the calculation of the moderating parameters, particularly useful when the materials are compounds of many elements. The second part of the work was dedicated to correlate the materials' MR values with the measured variation of reactivity induced by the insertion of the materials in the core of TRIGA Mark II reactor of the University of Pavia. This is possible by definition of a new parameter for the measure. This parameter, named S, depends on the total weight of the sample inserted in the reactor core

  8. Prognostic value of 18F-FDG PET image-based parameters in oesophageal cancer and impact of tumour delineation methodology

    International Nuclear Information System (INIS)

    Hatt, Mathieu; Visvikis, Dimitris; Tixier, Florent; Albarghach, Nidal M.; Pradier, Olivier; Cheze-le Rest, Catherine

    2011-01-01

    18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) image-derived parameters, such as standardized uptake value (SUV), functional tumour length (TL) and tumour volume (TV) or total lesion glycolysis (TLG), may be useful for determining prognosis in patients with oesophageal carcinoma. The objectives of this work were to investigate the prognostic value of these indices in oesophageal cancer patients undergoing combined chemoradiotherapy treatment and the impact of TV delineation strategies. A total of 45 patients were retrospectively analysed. Tumours were delineated on pretreatment 18 F-FDG scans using adaptive threshold and automatic (fuzzy locally adaptive Bayesian, FLAB) methodologies. The maximum standardized uptake value (SUV max ), SUV peak , SUV mean , TL, TV and TLG were computed. The prognostic value of each parameter for overall survival was investigated using Kaplan-Meier and Cox regression models for univariate and multivariate analyses, respectively. Large differences were observed between methodologies (from -140 to +50% for TV). SUV measurements were not significant prognostic factors for overall survival, whereas TV, TL and TLG were, irrespective of the segmentation strategy. After multivariate analysis including standard tumour staging, only TV (p < 0.002) and TL (p = 0.042) determined using FLAB were independent prognostic factors. Whereas no SUV measurement was a significant prognostic factor, TV, TL and TLG were significant prognostic factors for overall survival, irrespective of the delineation methodology. Only functional TV and TL derived using FLAB were independent prognostic factors, highlighting the need for accurate and robust PET tumour delineation tools for oncology applications. (orig.)

  9. A Framework for Measuring Low-Value Care.

    Science.gov (United States)

    Miller, George; Rhyan, Corwin; Beaudin-Seiler, Beth; Hughes-Cromwick, Paul

    2018-04-01

    It has been estimated that more than 30% of health care spending in the United States is wasteful, and that low-value care, which drives up costs unnecessarily while increasing patient risk, is a significant component of wasteful spending. To address the need for an ability to measure the magnitude of low-value care nationwide, identify the clinical services that are the greatest contributors to waste, and track progress toward eliminating low-value use of these services. Such an ability could provide valuable input to the efforts of policymakers and health systems to improve efficiency. We reviewed existing methods that could contribute to measuring low-value care and developed an integrated framework that combines multiple methods to comprehensively estimate and track the magnitude and principal sources of clinical waste. We also identified a process and needed research for implementing the framework. A comprehensive methodology for measuring and tracking low-value care in the United States would provide an important contribution toward reducing waste. Implementation of the framework described in this article appears feasible, and the proposed research program will allow moving incrementally toward full implementation while providing a near-term capability for measuring low-value care that can be enhanced over time. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  10. Measuring Values in Environmental Research: A Test of an Environmental Portrait Value Questionnaire

    Science.gov (United States)

    Bouman, Thijs; Steg, Linda; Kiers, Henk A. L.

    2018-01-01

    Four human values are considered to underlie individuals’ environmental beliefs and behaviors: biospheric (i.e., concern for environment), altruistic (i.e., concern for others), egoistic (i.e., concern for personal resources) and hedonic values (i.e., concern for pleasure and comfort). These values are typically measured with an adapted and shortened version of the Schwartz Value Survey (SVS), to which we refer as the Environmental-SVS (E-SVS). Despite being well-validated, recent research has indicated some concerns about the SVS methodology (e.g., comprehensibility, self-presentation biases) and suggested an alternative method of measuring human values: The Portrait Value Questionnaire (PVQ). However, the PVQ has not yet been adapted and applied to measure values most relevant to understand environmental beliefs and behaviors. Therefore, we tested the Environmental-PVQ (E-PVQ) – a PVQ variant of E-SVS –and compared it with the E-SVS in two studies. Our findings provide strong support for the validity and reliability of both the E-SVS and E-PVQ. In addition, we find that respondents slightly preferred the E-PVQ over the E-SVS (Study 1). In general, both scales correlate similarly to environmental self-identity (Study 1), energy behaviors (Studies 1 and 2), pro-environmental personal norms, climate change beliefs and policy support (Study 2). Accordingly, both methodologies show highly similar results and seem well-suited for measuring human values underlying environmental behaviors and beliefs. PMID:29743874

  11. Analysis of radiological parameters associated with decreased fractional anisotropy values on diffusion tensor imaging in patients with lumbar spinal stenosis.

    Science.gov (United States)

    Wang, Xiandi; Wang, Hongli; Sun, Chi; Zhou, Shuyi; Meng, Tao; Lv, Feizhou; Ma, Xiaosheng; Xia, Xinlei; Jiang, Jianyuan

    2018-04-26

    Previous studies have indicated that decreased fractional anisotropy (FA) values on diffusion tensor imaging (DTI) are well correlated with the symptoms of nerve root compression. The aim of our study is to determine primary radiological parameters associated with decreased FA values in patients with lumbar spinal stenosis involving single L5 nerve root. Patients confirmed with single L5 nerve root compression by transforaminal nerve root blocks were included in this study. FA values of L5 nerve roots on both symptomatic and asymptomatic side were obtained. Conventional radiological parameters, such as disc height, degenerative scoliosis, dural sac cross-sectional area (DSCSA), foraminal height (FH), hypertrophic facet joint degeneration (HFJD), sagittal rotation (SR), sedimentation sign, sagittal translation and traction spur were measured. Correlation and regression analyses were performed between the radiological parameters and FA values of the symptomatic L5 nerve roots. A predictive regression equation was established. Twenty-one patients were included in this study. FA values were significantly lower at the symptomatic side comparing to the asymptomatic side (0.263 ± 0.069 vs. 0.334 ± 0.080, P = 0.038). DSCSA, FH, HFJD, and SR were significantly correlated with the decreased FA values, with r = 0.518, 0.443, 0.472 and - 0.910, respectively (P values, and the regression equation is FA = - 0.012 × SR + 0.002 × DSCSA. DSCSA and SR were primary contributors to decreased FA values in LSS patients involving single L5 nerve root, indicating that central canal decompression and segmental stability should be the first considerations in preoperative planning of these patients. These slides can be retrieved under Electronic Supplementary Material.

  12. Measuring values for cross-cultural research

    NARCIS (Netherlands)

    Maseland, R.K.J.; Hoorn, A.A.J. van

    2009-01-01

    This paper investigates the empirical relevance of the recent critique that values surveys, as they are, suffer from the problem of measuring marginal preferences rather than values. By surveying items from cross-cultural surveys by Hofstede, Inglehart and GLOBE, we show that the marginal

  13. Integration of neural networks with fuzzy reasoning for measuring operational parameters in a nuclear reactor

    International Nuclear Information System (INIS)

    Ikonomopoulos, A.; Tsoukalas, L.H.

    1993-01-01

    A novel approach is described for measuring variables with operational significance in a complex system such as a nuclear reactor. The methodology is based on the integration of artificial neural networks with fuzzy reasoning. Neural networks are used to map dynamic time series to a set of user-defined linguistic labels called fuzzy values. The process takes place in a manner analogous to that of measurement. Hence, the entire procedure is referred to as virtual measurement and its software implementation as a virtual measuring device. An optimization algorithm based on information criteria and fuzzy algebra augments the process and assists in the identification of different states of the monitored parameter. The proposed technique is applied for monitoring parameters such as performance, valve position, transient type, and reactivity. The results obtained from the application of the neural network-fuzzy reasoning integration in a high power research reactor clearly demonstrate the excellent tolerance of the virtual measuring device to faulty signals as well as its ability to accommodate noisy inputs

  14. Real time alpha value measurement with Feynman-α method utilizing time series data acquisition on low enriched uranium system

    International Nuclear Information System (INIS)

    Tonoike, Kotaro; Yamamoto, Toshihiro; Watanabe, Shoichi; Miyoshi, Yoshinori

    2003-01-01

    As a part of the development of a subcriticality monitoring system, a system which has a time series data acquisition function of detector signals and a real time evaluation function of alpha value with the Feynman-alpha method was established, with which the kinetic parameter (alpha value) was measured at the STACY heterogeneous core. The Hashimoto's difference filter was implemented in the system, which enables the measurement at a critical condition. The measurement result of the new system agreed with the pulsed neutron method. (author)

  15. Neutron Transmission and Capture Measurements and Resonance Parameter Analysis of Neodymium from 1eV to 500 eV

    International Nuclear Information System (INIS)

    DP Barry; MJ Trbovich; Y Danon; RC Block; RE Slovacek

    2005-01-01

    Neodymium is a 235 U fission product and is important for reactor neutronic calculations. The aim of the present work is to improve upon the existing neutron cross section data of neodymium. Neutron capture and transmission measurements were performed by the time-off-light technique at the Rensselaer Polytechnic Institute LINAC laboratory using metallic neodymium samples. The capture measurements were made at the 25-m flight station with a 16-segment NaI multiplicity detector, and the transmission measurements were performed at 15-m and 25-m flight stations, respectively, with 6 Li glass scintillation detectors. After the data were collected and reduced, resonance parameters were determined by combined fitting of the transmission and capture data with the multilevel R-matrix Bayesian code SAMMY. The resonance parameters for all naturally occurring neodymium isotopes were deduced within the energy range of 1 eV to 500 eV. The resulting resonance parameters were used to calculate the capture resonance integrals from this energy. The RPI parameters gave a resonance integral value of 32 ± 1 barns that is approximately 7% lower than that obtained with the ENDF-B/VI parameters. The current measurements significantly reduce the uncertainties on the resonance parameters when compared with previously published parameters

  16. Measuring industrial energy efficiency: Physical volume versus economic value

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, S.L.; Niefer, M.J.; Roop, J.M.

    1996-12-01

    This report examines several different measures of industrial output for use in constructing estimates of industrial energy efficiency and discusses some reasons for differences between the measures. Estimates of volume-based measures of output, as well as 3 value-based measures of output (value of production, value of shipments, and value added), are evaluated for 15 separate 4-digit industries. Volatility, simple growth rate, and trend growth rate estimates are made for each industry and each measure of output. Correlations are made between the volume- and value-based measures of output. Historical energy use data are collected for 5 of the industries for making energy- intensity estimates. Growth rates in energy use, energy intensity, and correlations between volume- and value-based measures of energy intensity are computed. There is large variability in growth trend estimates both long term and from year to year. While there is a high correlation between volume- and value-based measures of output for a few industries, typically the correlation is low, and this is exacerbated for estimates of energy intensity. Analysis revealed reasons for these low correlations. It appears that substantial work must be done before reliable measures of trends in the energy efficiency of industry can be accurately characterized.

  17. Effects of measurement noise on modal parameter identification

    International Nuclear Information System (INIS)

    Dorvash, S; Pakzad, S N

    2012-01-01

    In the past decade, much research has been conducted on data-driven structural health monitoring (SHM) algorithms with use of sensor measurements. A fundamental step in this SHM application is to identify the dynamic characteristics of structures. Despite the significant efforts devoted to development and enhancement of the modal parameter identification algorithms, there are still substantial uncertainties in the results obtained in real-life deployments. One of the sources of uncertainties in the results is the existence of noise in the measurement data. Depending on the subsequent application of the system identification, the level of uncertainty in the results and, consequently, the level of noise contamination can be very important. As an effort towards understanding the effect of measurement noise on the modal identification, this paper presents parameters that quantify the effects of measurement noise on the modal identification process and determine their influence on the accuracy of results. The performance of these parameters is validated by a numerically simulated example. They are then used to investigate the accuracy of identified modal properties of the Golden Gate Bridge using ambient data collected by wireless sensors. The vibration monitoring tests of the Golden Gate Bridge provided two synchronized data sets collected by two different sensor types. The influence of the sensor noise level on the accuracy of results is investigated throughout this work and it is shown that high quality sensors provide more accurate results as the physical contribution of response in their measured data is significantly higher. Additionally, higher purity and consistency of modal parameters, identified by higher quality sensors, is observed in the results. (paper)

  18. THE ISSUES IN THE MEASUREMENT OF POSTMATERIAL VALUES

    Directory of Open Access Journals (Sweden)

    Svetlana Tasić

    2012-02-01

    Full Text Available The measurement of postmaterial values includes measuring of the views on the preservation ofpeace, freedom of speech, environmental protection, tolerance and everything else that is contrary tothe concept of measuring the material values, that is physical and economic variables. Measurementof postmaterial values is based on the application of 4 or 12 items scale that refers to the materialismor postmaterialism in certain country. There are several issues and limitations in the application ofpostmaterial values measurement scale which can cause significant error, in other words bias inmeasurement. One of the most interesting issues is the impact of question order change on themeasurement results of postmaterial values. Using the results of empirical research it is shown thatthis effect is significant and, also it is particularly examined the intensity of this effect consideringgender and level of education based on the sample of respondents from urban Serbia.

  19. Psychoacoustic parameters and its measuring system; Onshitsu hyoka wo hyokasuru tame no parameter to keisoku system

    Energy Technology Data Exchange (ETDEWEB)

    Ohashi, M.; Imaizumi, H.; Ono, T. [Ono Sokki Co. Ltd., Tokyo (Japan)

    1998-05-01

    Human auditory sensation has both extremely excellent performance and general versatility as sound analyzer. At present, it is impossible to make equipment with the same functions as human being, and describe an auditory sensation function as acoustic sensor even by any physical analysis techniques. However, extraction of auditory sensation parameters is becoming possible by using psychoacoustics and binaural signal processing. This paper mainly explains the calculation method of sound quality evaluation parameters derived from psychoacoustic results based on a sound quality evaluation system under development by the authors. This system is based on binaural measurement by dummy head, and calculates psychoacoustic parameters such as loudness, sharpness, roughness, fluctuation strength and tonality through frequency analysis of the measured stereo signals. The system also calculates 2-D parameters such as sensory pleasantness and unbiased annoyance based on the above parameters. 12 refs., 4 figs.

  20. Implications of the top quark mass measurement for the CKM parameters x$_{s}$ and CP asymmetries

    CERN Document Server

    Ali, A

    1995-01-01

    Motivated by the recent determination of the top quark mass by the CDF collaboration, \\mt =174 \\pm 10 ^{+13}_{-12} GeV, we review and update constraints on the parameters of the quark flavour mixing matrix V_{CKM} in the standard model. In performing these fits, we use inputs from the measurements of \\abseps, the CP-violating parameter in K decays, \\xd = (\\delm)/\\Gamma, the mixing parameter in \\bdbdbar\\ mixing, the present measurements of the matrix elements \\absvcb and \\absvub, and the B-hadron lifetimes. The CDF value for \\mt considerably reduces the CKM-parameter space previously allowed. An interesting result of our analysis is that the present data can be used to restrict the coupling constant product ratio f_{B_d}\\sqrt{B_{B_d}} to the range 110-270 MeV -- in comfortable agreement with existing theoretical estimates of this quantity. We use the updated CKM matrix to predict the \\bsbsbar\\ mixing ratio \\xs, as well as the quantities \\sin 2\\alpha, \\sin 2\\beta and \\sin^2\\gamma, which characterize CP-violatin...

  1. Study of radiation exposure rate on the measurement points in Kartini reactor hall as based to determine operation safety parameters (KBO)

    International Nuclear Information System (INIS)

    Mahrus Salam; Elisabeth Supriyatni; Fajar Panuntun

    2016-01-01

    In the operation of nuclear facility there are safety parameters, which is the value of the conservatively maximum limit to ensure that all of the uncertainty in the analysis of facility operations safety have been considered, such as uncertainty of measurement, response time and uncertainty calculation tool, and is get a long to others value of normal operating condition limits, in other words, there are still allowed or permitted. Calculation of the radiation exposure rate on five measurement points (50 cm above the water surface of reactor pool, above interim storage (bulk shielding), reactor deck, thermal column and sub critical facility) and to be compared to the operation safety parameters (KBO) of Kartini reactor. The exposure rate value is obtained by calculating the source term of radioactivity on the core, attenuation resulting from the radiation shielding and measurement distance. From the calculation obtained that the value of gamma exposure rate of 50 cm above the water surface of reactor pool is 96.91 mR/hr (KBO<100 mR/hr), on the deck of Bulk Shielding amounted to 1.70 mR/h (KBO<2.5 mR/hr), on the reactor deck amounted to 5.73 mR/hr (KBO<10 mR/hr), on the Thermal Column amounted to 2.73 mR/hr (KBO<10 mR/hr) and on the sub critical facility amounted to 1.148 mR/hr (KBO<2.5 mR/hr). The value of gamma exposure rate at 5 locations measurements are still less than the operation safety parameters (KBO), it means that the reactor is safe to be operated. (author)

  2. The internal strain parameter of gallium arsenide measured by energy-dispersive X-ray diffraction

    International Nuclear Information System (INIS)

    Cousins, C.S.G.; Sheldon, B.J.; Webster, G.E.; Gerward, L.; Selsmark, B.; Staun Olsen, J.

    1989-01-01

    The internal strain parameter of GaAs has been measured by observing the stress-dependence of the integrated intensity of the weak 006 reflection, with the compressive stress along the [1anti 10] axis. An energy-dispersive technique was employed so that the reflection could be obtained at a photon energy close to the minimum in the structure factor, thereby approaching closely the strictly-forbidden condition that applies at any energy in the diamond structure. A value anti A=-0.138±0.005, equivalent to a bond-bending parameter ζ=0.55=0.02, has been found. This is in good agreement with recent theoretical calculations and indirect determinations related to the bandstructure of GaAs. (orig.)

  3. A direct method for computing extreme value (Gumbel) parameters for gapped biological sequence alignments.

    Science.gov (United States)

    Quinn, Terrance; Sinkala, Zachariah

    2014-01-01

    We develop a general method for computing extreme value distribution (Gumbel, 1958) parameters for gapped alignments. Our approach uses mixture distribution theory to obtain associated BLOSUM matrices for gapped alignments, which in turn are used for determining significance of gapped alignment scores for pairs of biological sequences. We compare our results with parameters already obtained in the literature.

  4. THE UNCERTAINTIES OF ENVIRONMENT'S PARAMETERS MEASUREMENTS AS TOLLS OF THE MEASUREMENTS QUALITY IMPROVEMENT

    Directory of Open Access Journals (Sweden)

    Miroslav Badida

    2008-06-01

    Full Text Available Identification of the noise measuring uncertainties by declared measured values is unconditionally necessary and required by legislative. Uncertainty of the measurements expresses all errors that accrue during the measuring. B y indication of uncertainties the measure documents that the objective value is with certain probability found in the interval that is bounded by the measurement uncertainty. The paper deals with the methodology of the uncertainty calculation by noise measurements in living and working environments. metal processing industry and building materials industry.

  5. Intra-observer reproducibility and interobserver reliability of the radiographic parameters in the Spinal Deformity Study Group's AIS Radiographic Measurement Manual.

    Science.gov (United States)

    Dang, Natasha Radhika; Moreau, Marc J; Hill, Douglas L; Mahood, James K; Raso, James

    2005-05-01

    Retrospective cross-sectional assessment of the reproducibility and reliability of radiographic parameters. To measure the intra-examiner and interexaminer reproducibility and reliability of salient radiographic features. The management and treatment of adolescent idiopathic scoliosis (AIS) depends on accurate and reproducible radiographic measurements of the deformity. Ten sets of radiographs were randomly selected from a sample of patients with AIS, with initial curves between 20 degrees and 45 degrees. Fourteen measures of the deformity were measured from posteroanterior and lateral radiographs by 2 examiners, and were repeated 5 times at intervals of 3-5 days. Intra-examiner and interexaminer differences were examined. The parameters include measures of curve size, spinal imbalance, sagittal kyphosis and alignment, maximum apical vertebral rotation, T1 tilt, spondylolysis/spondylolisthesis, and skeletal age. Intra-examiner reproducibility was generally excellent for parameters measured from the posteroanterior radiographs but only fair to good for parameters from the lateral radiographs, in which some landmarks were not clearly visible. Of the 13 parameters observed, 7 had excellent interobserver reliability. The measurements from the lateral radiograph were less reproducible and reliable and, thus, may not add value to the assessment of AIS. Taking additional measures encourages a systematic and comprehensive assessment of spinal radiographs.

  6. Influence of parameter values on the oscillation sensitivities of two p53-Mdm2 models.

    Science.gov (United States)

    Cuba, Christian E; Valle, Alexander R; Ayala-Charca, Giancarlo; Villota, Elizabeth R; Coronado, Alberto M

    2015-09-01

    Biomolecular networks that present oscillatory behavior are ubiquitous in nature. While some design principles for robust oscillations have been identified, it is not well understood how these oscillations are affected when the kinetic parameters are constantly changing or are not precisely known, as often occurs in cellular environments. Many models of diverse complexity level, for systems such as circadian rhythms, cell cycle or the p53 network, have been proposed. Here we assess the influence of hundreds of different parameter sets on the sensitivities of two configurations of a well-known oscillatory system, the p53 core network. We show that, for both models and all parameter sets, the parameter related to the p53 positive feedback, i.e. self-promotion, is the only one that presents sizeable sensitivities on extrema, periods and delay. Moreover, varying the parameter set values to change the dynamical characteristics of the response is more restricted in the simple model, whereas the complex model shows greater tunability. These results highlight the importance of the presence of specific network patterns, in addition to the role of parameter values, when we want to characterize oscillatory biochemical systems.

  7. Dynamic response of carbon nanotube field-effect transistors analyzed by S-parameters measurement

    International Nuclear Information System (INIS)

    Bethoux, J.-M.; Happy, H.; Dambrine, G.; Derycke, V.; Goffman, M.; Bourgoin, J.-P.

    2006-01-01

    Carbon nanotube field-effect transistors (CN-FET) with a metallic back gate have been fabricated. By assembling a number of CNs in parallel, driving currents in the mA range have been obtained. The dynamic response of the CN-FETs has been investigated through S-parameters measurements. A current gain (|H 21 | 2 ) cut-off frequency (f t ) of 8 GHz, and a maximum stable gain (MSG) value of 10 dB at 1 GHz have been obtained. The extraction of an equivalent circuit is proposed

  8. Measurement Error Estimation for Capacitive Voltage Transformer by Insulation Parameters

    Directory of Open Access Journals (Sweden)

    Bin Chen

    2017-03-01

    Full Text Available Measurement errors of a capacitive voltage transformer (CVT are relevant to its equivalent parameters for which its capacitive divider contributes the most. In daily operation, dielectric aging, moisture, dielectric breakdown, etc., it will exert mixing effects on a capacitive divider’s insulation characteristics, leading to fluctuation in equivalent parameters which result in the measurement error. This paper proposes an equivalent circuit model to represent a CVT which incorporates insulation characteristics of a capacitive divider. After software simulation and laboratory experiments, the relationship between measurement errors and insulation parameters is obtained. It indicates that variation of insulation parameters in a CVT will cause a reasonable measurement error. From field tests and calculation, equivalent capacitance mainly affects magnitude error, while dielectric loss mainly affects phase error. As capacitance changes 0.2%, magnitude error can reach −0.2%. As dielectric loss factor changes 0.2%, phase error can reach 5′. An increase of equivalent capacitance and dielectric loss factor in the high-voltage capacitor will cause a positive real power measurement error. An increase of equivalent capacitance and dielectric loss factor in the low-voltage capacitor will cause a negative real power measurement error.

  9. Whole lesion histogram analysis of meningiomas derived from ADC values. Correlation with several cellularity parameters, proliferation index KI 67, nucleic content, and membrane permeability.

    Science.gov (United States)

    Surov, Alexey; Hamerla, Gordian; Meyer, Hans Jonas; Winter, Karsten; Schob, Stefan; Fiedler, Eckhard

    2018-09-01

    To analyze several histopathological features and their possible correlations with whole lesion histogram analysis derived from ADC maps in meningioma. The retrospective study involved 36 patients with primary meningiomas. For every tumor, the following histogram analysis parameters of apparent diffusion coefficient (ADC) were calculated: ADC mean , ADC max , ADC min , ADC median , ADC mode , ADC percentiles: P10, P25, P75, P90, as well kurtosis, skewness, and entropy. All measures were performed by two radiologists. Proliferation index KI 67, minimal, maximal and mean cell count, total nucleic area, and expression of water channel aquaporin 4 (AQP4) were estimated. Spearman's correlation coefficient was used to analyze associations between investigated parameters. A perfect interobserver agreement for all ADC values (0.84-0.97) was identified. All ADC values correlated inversely with tumor cellularity with the strongest correlation between P10, P25 and mean cell count (-0.558). KI 67 correlated inversely with all ADC values except ADC min . ADC parameters did not correlate with total nucleic area. All ADC values correlated statistically significant with expression of AQP4. ADC histogram analysis is a valid method with an excellent interobserver agreement. Cellularity parameters and proliferation potential are associated with different ADC values. Membrane permeability may play a greater role for water diffusion than cell count and proliferation activity. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Data Qualification Report For DTN: MO0012RIB00065.002, Parameter Values For Transfer Coefficients

    International Nuclear Information System (INIS)

    C.H. Tung

    2001-01-01

    A data-qualification evaluation was conducted on Reference Information Base (RIB) data set MOO0 12RIB00065.002, ''Parameter Values for Transfer Coefficients''. The corroborating data method was used to evaluate the data. This method was selected because it closely matches the literature-review method followed to select parameter values. Five criteria were considered when the corroborating method was used: adequacy of the corroborative literature, sufficiency of value-selection criteria, implementation of the selection criteria, documentation of the process, and whether the analysis was conducted in accordance with applicable quality assurance (QA) procedures. Three criteria were used when a literature review was not conducted: appropriate logic used to select parameters, documentation of the process, and whether the analysis was conducted in accordance with applicable QA procedures. The RIB data item, the associated Analysis and Model Report (AMR), the corroborative literature, and the results of an audit revision O/ICN--0 of the AMR were examined. All calculations and the selection process for all values were repeated and confirmed. The qualification team concluded: (1) A sufficient quantity of corroborative literature was reviewed and no additional literature was identified that should have been considered. (2) The selection criteria were sufficient and resulted in valid parameter values. (3) The process was well defined, adequately documented in the AMR, and correctly followed. (4) The analysis was developed in accordance with applicable QA procedures. No negative findings were documented that resulted in questions about the quality of the data. The qualification team therefore recommends that the qualification status of RIB data set MO0012RIB00065.002 be changed to qualified

  11. The Sensitivity of the Input Impedance Parameters of Track Circuits to Changes in the Parameters of the Track

    Directory of Open Access Journals (Sweden)

    Lubomir Ivanek

    2017-01-01

    Full Text Available This paper deals with the sensitivity of the input impedance of an open track circuit in the event that the parameters of the track are changed. Weather conditions and the state of pollution are the most common reasons for parameter changes. The results were obtained from the measured values of the parameters R (resistance, G (conductance, L (inductance, and C (capacitance of a rail superstructure depending on the frequency. Measurements were performed on a railway siding in Orlova. The results are used to design a predictor of occupancy of a track section. In particular, we were interested in the frequencies of 75 and 275 Hz for this purpose. Many parameter values of track substructures have already been solved in different works in literature. At first, we had planned to use the parameter values from these sources when we designed the predictor. Deviations between them, however, are large and often differ by three orders of magnitude (see Tab.8. From this perspective, this article presents data that have been updated using modern measurement devices and computer technology. And above all, it shows a transmission (cascade matrix used to determine the parameters.

  12. Determination of complex microcalorimeter parameters with impedance measurements

    International Nuclear Information System (INIS)

    Saab, T.; Bandler, S.R.; Chervenak, J.; Figueroa-Feliciano, E.; Finkbeiner, F.; Iyomoto, N.; Kelley, R.L.; Kilbourne, C.A.; Lindeman, M.A.; Porter, F.S.; Sadleir, J.

    2006-01-01

    The proper understanding and modeling of a microcalorimeter's response requires accurate knowledge of a handful of parameters, such as C, G, α. While a few of these parameters are directly determined from the IV characteristics, some others, notoriously the heat capacity (C) and α, appear in degenerate combinations in most measurable quantities. The consideration of a complex microcalorimeter leads to an added ambiguity in the determination of the parameters. In general, the dependence of the microcalorimeter's complex impedance on these various parameters varies with frequency. This dependence allows us to determine individual parameters by fitting the prediction of the microcalorimeter model to impedance data. In this paper we describe efforts at characterizing the Goddard X-ray microcalorimeters. With the parameters determined by this method, we compare the pulse shape and noise spectra predictions to data taken with the same devices

  13. Value of quantitative MRI parameters in predicting and evaluating clinical outcome in conservatively treated patients with chronic midportion Achilles tendinopathy: A prospective study.

    Science.gov (United States)

    Tsehaie, J; Poot, D H J; Oei, E H G; Verhaar, J A N; de Vos, R J

    2017-07-01

    To evaluate whether baseline MRI parameters provide prognostic value for clinical outcome, and to study correlation between MRI parameters and clinical outcome. Observational prospective cohort study. Patients with chronic midportion Achilles tendinopathy were included and performed a 16-week eccentric calf-muscle exercise program. Outcome measurements were the validated Victorian Institute of Sports Assessment-Achilles (VISA-A) questionnaire and MRI parameters at baseline and after 24 weeks. The following MRI parameters were assessed: tendon volume (Volume), tendon maximum cross-sectional area (CSA), tendon maximum anterior-posterior diameter (AP), and signal intensity (SI). Intra-class correlation coefficients (ICCs) and minimum detectable changes (MDCs) for each parameter were established in a reliability analysis. Twenty-five patients were included and complete follow-up was achieved in 20 patients. The average VISA-A scores increased significantly with 12.3 points (27.6%). The reliability was fair-good for all MRI-parameters with ICCs>0.50. Average tendon volume and CSA decreased significantly with 0.28cm 3 (5.2%) and 4.52mm 2 (4.6%) respectively. Other MRI parameters did not change significantly. None of the baseline MRI parameters were univariately associated with VISA-A change after 24 weeks. MRI SI increase over 24 weeks was positively correlated with the VISA-A score improvement (B=0.7, R 2 =0.490, p=0.02). Tendon volume and CSA decreased significantly after 24 weeks of conservative treatment. As these differences were within the MDC limits, they could be a result of a measurement error. Furthermore, MRI parameters at baseline did not predict the change in symptoms, and therefore have no added value in providing a prognosis in daily clinical practice. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  14. Implementation of Positive Operator-Valued Measure in Passive Faraday Mirror Attack

    International Nuclear Information System (INIS)

    Wang Wei-Long; Gao Ming; Ma Zhi

    2015-01-01

    Passive Faraday-mirror (PFM) attack is based on imperfect Faraday mirrors in practical quantum cryptography systems and a set of three-dimensional Positive Operator-Valued Measure (POVM) operators plays an important role in this attack. In this paper, we propose a simple scheme to implement the POVM in PFM attack on an Faraday–Michelson quantum cryptography system. Since the POVM can not be implemented directly with previous methods, in this scheme it needs to expand the states sent by Alice and the POVM operators in the attack into four-dimensional Hilbert space first, without changing the attacking effect by calculation. Based on the methods proposed by Ahnert and Payne, the linear-optical setup for implementing the POVM operators is derived. At last, the complete setup for realizing the PFM attack is presented with all parameters. Furthermore, our scheme can also be applied to realize PFM attack on a plug-and-play system by changing the parameters in the setup. (paper)

  15. Measurement of the Stokes parameters of light

    International Nuclear Information System (INIS)

    Berry, H.G.; Gabrielse, G.; Livingston, A.E.

    1977-01-01

    We describe a measuring system for determing the state of polarization of a beam of light in terms of its Stokes parameters. The technique which can be fully automated incorporates a monochromator and single photon counting detection and can thus be applied over a large wavelength range for very weak optical signals. Fourier transformation of the data by an on-line minicomputer allows immediate calculation of the Stokes parameters. We discuss special applications to light emitted from excited atomic systems with and without cylindrical symmetry

  16. Fair Value in the light of IFRS 13 «Fair Value Measurement»

    OpenAIRE

    V.V. Svitselska

    2015-01-01

    The main provisions of IFRS 13 «Fair Value Measurement» have been researched as well as its critical analysis has been conducted. Comparison of the previous and the new definition of the concept «fair value» has been done on the basis of what the shortcomings of the previous definition have been highlighted, the characteristic features and advantages of new definition from IFRS 13 «Fair Value Measurement» have been outlined. It has been proved that new interpretation of the concept of «fair v...

  17. Effective diffusion coefficients and porosity values for argillaceous rocks and bentonite: measured and estimated values for the provisional safety analyses for SGT-E2

    International Nuclear Information System (INIS)

    Van Loon, L.R.

    2014-11-01

    In Stage 2 of the Sectoral Plan for Deep Geological Repositories, safety analyses have to be performed. Geochemical parameters describing the transport and retardation of radionuclides in the argillaceous rocks considered and in compacted bentonite are required. In the present report, diffusion parameters for all clay host rocks, confining units and compacted bentonite are derived. Diffusion of tritiated water (HTO), "3"6Cl"- and "2"2Na"+ was studied. The measurements gave values for effective diffusion coefficients (D_e) and diffusion accessible porosities. The general observed trend "N"aD_e > "H"T"OD_e > "C"lD_e is in agreement with the expected behaviour of the three species in clay materials: ion exchanging cations show an enhanced mobility due to surface diffusion effects and anions are slowed down due to anion exclusion. Due to the negatively charged clay surfaces, anionic species are repelled from these surfaces resulting in an accessible porosity that is smaller than the total porosity as measured with HTO. The effect of porewater composition on the diffusion of HTO, "3"6Cl"- and "2"2Na"+ in Opalinus Clay was investigated. For ionic strength (IS) values between 0.17 M and 1.07 M, no significant effect on D_e could be observed. In the case of "3"6Cl"-, no effect on the accessible porosity was observed. The anion diffusion accessible porosity equals 50-60 % of the total porosity, independent on the ionic strength of the porewater. The diffusion parameters were measured on sedimentary rocks such as chalk, clay and limestone rocks. All data could be described by one single modified version of Archie's relation (extended Archie's relation). For values of porosity greater than about 0.1, the classical Archie's relation was valid. For values smaller than 0.1, the data deviated from the classical Archie's relation; this can be explained by additional changes of tortuosity with porosity values. At high porosity values (low density rocks), the microfabric of the clay

  18. Effects of Initial Values and Convergence Criterion in the Two-Parameter Logistic Model When Estimating the Latent Distribution in BILOG-MG 3.

    Directory of Open Access Journals (Sweden)

    Ingo W Nader

    Full Text Available Parameters of the two-parameter logistic model are generally estimated via the expectation-maximization algorithm, which improves initial values for all parameters iteratively until convergence is reached. Effects of initial values are rarely discussed in item response theory (IRT, but initial values were recently found to affect item parameters when estimating the latent distribution with full non-parametric maximum likelihood. However, this method is rarely used in practice. Hence, the present study investigated effects of initial values on item parameter bias and on recovery of item characteristic curves in BILOG-MG 3, a widely used IRT software package. Results showed notable effects of initial values on item parameters. For tighter convergence criteria, effects of initial values decreased, but item parameter bias increased, and the recovery of the latent distribution worsened. For practical application, it is advised to use the BILOG default convergence criterion with appropriate initial values when estimating the latent distribution from data.

  19. Local drift parameter, j/n/sub e/ and resistivity anomaly measurements in CTX spheromaks

    International Nuclear Information System (INIS)

    Hoida, H.W.; Barnes, C.W.; Henins, I.; Jarboe, T.R.; Marklin, G.; Buchenauer, C.J.; Knox, S.O.

    1985-01-01

    In a spheromak, the magnetic fields confining the plasma are generated primarily by internal currents rather than external coils. In order to provide information on the possible existence of current-driven microinstabilities, localized measurements of the ratio of the drift velocity of the electrons generating the internal current to their thermal velocity, V/sub d//V/sub th/ proportional to j/n/sub e/√T/sub e/ (known as the drift or streaming parameter), and j/n/sub e/ (proportional to V/sub d/) are needed. These microinstabilities are in some theories associated with an increase in the resistivity anomaly factor (eta/eta/sub Spitzer/). We present results on local measurements (at the magnetic axis) of the values of V/sub d//V/sub th/ and eta/eta/sub Spitzer/ by combining data from the spatially-resolved diagnostics employed on the CTX spheromak experiment, coupled with current density profile information from equilibrium measurements. The values of V/sub d//V/sub th/ and j/n/sub e/ appear to be correlated with local variations in eta/eta/sub Spitzer/, and can be changed by varying the plasma density. Data sets are presented for three values of n/sub e/

  20. Dynamic response of carbon nanotube field-effect transistors analyzed by S-parameters measurement

    Energy Technology Data Exchange (ETDEWEB)

    Bethoux, J.-M. [Institut d' Electronique, de Microelectronique et de Nanotechnologie, C.N.R.S. U.M.R. 8520, BP 60069, F-59652, Villeneuve d' Ascq Cedex (France); Happy, H. [Institut d' Electronique, de Microelectronique et de Nanotechnologie, C.N.R.S. U.M.R. 8520, BP 60069, F-59652, Villeneuve d' Ascq Cedex (France)]. E-mail: henri.happy@iemn.univ-lille1.fr; Dambrine, G. [Institut d' Electronique, de Microelectronique et de Nanotechnologie, C.N.R.S. U.M.R. 8520, BP 60069, F-59652, Villeneuve d' Ascq Cedex (France); Derycke, V. [Laboratoire d' Electronique Moleculaire, SPEC, Commissariat a l' Energie Atomique, Saclay F-91191, Gif sur Yvette Cedex (France); Goffman, M. [Laboratoire d' Electronique Moleculaire, SPEC, Commissariat a l' Energie Atomique, Saclay F-91191, Gif sur Yvette Cedex (France); Bourgoin, J.-P. [Laboratoire d' Electronique Moleculaire, SPEC, Commissariat a l' Energie Atomique, Saclay F-91191, Gif sur Yvette Cedex (France)

    2006-12-15

    Carbon nanotube field-effect transistors (CN-FET) with a metallic back gate have been fabricated. By assembling a number of CNs in parallel, driving currents in the mA range have been obtained. The dynamic response of the CN-FETs has been investigated through S-parameters measurements. A current gain (|H {sub 21}|{sup 2}) cut-off frequency (f {sub t}) of 8 GHz, and a maximum stable gain (MSG) value of 10 dB at 1 GHz have been obtained. The extraction of an equivalent circuit is proposed.

  1. Optimal parameters of the SVM for temperature prediction

    Directory of Open Access Journals (Sweden)

    X. Shi

    2015-05-01

    Full Text Available This paper established three different optimization models in order to predict the Foping station temperature value. The dimension was reduced to change multivariate climate factors into a few variables by principal component analysis (PCA. And the parameters of support vector machine (SVM were optimized with genetic algorithm (GA, particle swarm optimization (PSO and developed genetic algorithm. The most suitable method was applied for parameter optimization by comparing the results of three different models. The results are as follows: The developed genetic algorithm optimization parameters of the predicted values were closest to the measured value after the analog trend, and it is the most fitting measured value trends, and its homing speed is relatively fast.

  2. U-value measurements on ISO round Robin window

    DEFF Research Database (Denmark)

    Duer, Karsten

    1997-01-01

    9 laboratories in 6 european and 2 north american countries have participated in a round robin U-value test of a standard facade window. The objective of the round robin test was to verify that the ISO/CEN proposals for U-value measurement standard is robust.......9 laboratories in 6 european and 2 north american countries have participated in a round robin U-value test of a standard facade window. The objective of the round robin test was to verify that the ISO/CEN proposals for U-value measurement standard is robust....

  3. Multiple and sign-changing solutions for discrete Robin boundary value problem with parameter dependence

    Directory of Open Access Journals (Sweden)

    Long Yuhua

    2017-12-01

    Full Text Available In this paper, we study second-order nonlinear discrete Robin boundary value problem with parameter dependence. Applying invariant sets of descending flow and variational methods, we establish some new sufficient conditions on the existence of sign-changing solutions, positive solutions and negative solutions of the system when the parameter belongs to appropriate intervals. In addition, an example is given to illustrate our results.

  4. Measurement of small dispersion values in optical components

    DEFF Research Database (Denmark)

    Peucheret, Christophe; Liu, Fenghai; Pedersen, Rune Johan Skullerud

    1999-01-01

    It is reported that small dispersion values in optical components can be measured using the RF modulation method originally restricted to large dispersions. Using a constant dispersion offset, arbitrarily small dispersion values can be measured with a resolution as good as 1.2 ps/nm....

  5. 40 CFR 91.406 - Engine parameters to be measured and recorded.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine parameters to be measured and recorded. 91.406 Section 91.406 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Procedures § 91.406 Engine parameters to be measured and recorded. Measure or calculate, then record, the...

  6. 40 CFR 90.406 - Engine parameters to be measured and recorded.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine parameters to be measured and recorded. 90.406 Section 90.406 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Gaseous Exhaust Test Procedures § 90.406 Engine parameters to be measured and recorded. Measure or...

  7. Estimation of Aerodynamic Parameters in Conditions of Measurement

    Directory of Open Access Journals (Sweden)

    Htang Om Moung

    2017-01-01

    Full Text Available The paper discusses the problem of aircraft parameter identification in conditions of measurement noises. It is assumed that all the signals involved into the process of identification are subjects to measurement noises, that is measurement random errors normally distributed. The results of simulation are presented which show the relation between the noises standard deviations and the accuracy of identification.

  8. Research on CO2 ejector component efficiencies by experiment measurement and distributed-parameter modeling

    International Nuclear Information System (INIS)

    Zheng, Lixing; Deng, Jianqiang

    2017-01-01

    Highlights: • The ejector distributed-parameter model is developed to study ejector efficiencies. • Feasible component and total efficiency correlations of ejector are established. • New efficiency correlations are applied to obtain dynamic characteristics of EERC. • More suitable fixed efficiency value can be determined by the proposed correlations. - Abstract: In this study we combine the experimental measurement data and the theoretical model of ejector to determine CO 2 ejector component efficiencies including the motive nozzle, suction chamber, mixing section, diffuser as well as the total ejector efficiency. The ejector is modeled utilizing the distributed-parameter method, and the flow passage is divided into a number of elements and the governing equations are formulated based on the differential equation of mass, momentum and energy conservation. The efficiencies of ejector are investigated under different ejector geometric parameters and operational conditions, and the corresponding empirical correlations are established. Moreover, the correlations are incorporated into a transient model of transcritical CO 2 ejector expansion refrigeration cycle (EERC) and the dynamic simulations is performed based on variable component efficiencies and fixed values. The motive nozzle, suction chamber, mixing section and diffuser efficiencies vary from 0.74 to 0.89, 0.86 to 0.96, 0.73 to 0.9 and 0.75 to 0.95 under the studied conditions, respectively. The response diversities of suction flow pressure and discharge pressure are obvious between the variable efficiencies and fixed efficiencies referring to the previous studies, while when the fixed value is determined by the presented correlations, their response differences are basically the same.

  9. Fluctuations of physical values in statistical mechanics

    International Nuclear Information System (INIS)

    Zaripov, R.G.

    1999-01-01

    The new matrix inequalities for the boundary of measurement accuracy of physical values in the ensemble of quantum systems were obtained. The multidimensional thermodynamical parameter measurement is estimated. The matrix inequalities obtained are quantum analogs of the Cramer-Rao information inequalities in mathematical statistics. The quantity of information in quantum mechanical measurement, connected with the boundaries of jointly measurable values in one macroscopic experiment was determined. The lower boundary of the variance of estimation of multidimensional quantum mechanical parameter was found. (author)

  10. Impact of hierarchy upon the values of neutrino mixing parameters

    International Nuclear Information System (INIS)

    Escamilla-Roa, J.; Ernst, D. J.; Latimer, D. C.

    2010-01-01

    A neutrino-oscillation analysis is performed of the more finely binned Super-Kamiokande (Super-K) atmospheric, MINOS, and CHOOZ data to examine the effect of neutrino hierarchy in this data set on the value of θ 13 and the deviation of θ 23 from maximal mixing. Exact oscillation probabilities are used, thus incorporating all powers of θ 13 and ε:=θ 23 -π/4. The extracted oscillation parameters are found to be dependent on the hierarchy, particularly for θ 13 . We find, at a 90% confidence level, that these parameters are Δ 32 =2.44 -0.20 +0.26 and 2.48 -0.22 +0.25 x10 -3 eV 2 , ε=θ 23 -π/4=0.06 -0.16 +0.06 and 0.06 -0.17 +0.08 , and θ 13 =-0.07 -0.11 +0.18 and -0.13 -0.16 +0.23 , for the normal and inverted hierarchies, respectively. The inverted hierarchy is preferred at a statistically insignificant level of 0.3σ.

  11. Measurements of diffusion parameters of methanol on gamma-irradiated polycarbonate

    International Nuclear Information System (INIS)

    Silva, Pietro P.J.C.G.P.O.; Araujo, Elmo S.

    2013-01-01

    Polycarbonate (PC) is an engineering polymer which presents interesting properties such as toughness, light weight and transparency. This material has been used for several important applications including in the medical field. In this particular application, polycarbonate has been exposed frequently to gamma irradiation and to chemical environment that can be able to product significant changes in polymer structure that may lead to future catastrophic fail and rupture. Polymer structural damages induced by gamma irradiation or chemical attack (environment stress cracking) have been studied by several research groups for many years and for many solvent-polymer systems, but few reporters present informations about the simultaneous occurrence of these effects. This present work has the goal to understand the diffusion process of methanol in polycarbonate and to determinate the diffusion parameters on polymer system under 100 kGy of gamma irradiation. Swelling experiments were performed at the samples of polycarbonate divided in two groups: PC-0 (without dose) and PC-100 (with 100 kGy of dose). Diffusion parameters (D) may be measured by slope of the sorption curve for polymers with Fickian behavior. A comparison of the D parameters was made for each set of sample. There were no significant differences on D values of sample groups observed due to the radiation effects. However, stress strain curves obtained show that methanol has great influence on mechanical behavior of PC but the radiation dose don't have significant influence on this mechanical behavior. (author)

  12. Value of diffusion-weighted MR imaging using various parameters for assessment and characterization of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Koyama, Hisanobu; Ohno, Yoshiharu; Seki, Shinichiro; Nishio, Mizuho; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Maniwa, Yoshimasa; Itoh, Tomoo; Nishimura, Yoshihiro; Sugimura, Kazuro

    2015-01-01

    Highlights: •Signal–intensity ratio evaluation between lesion and spinal cord is practical method. •Apparent diffusion coefficients may not contribute to the diagnosis of malignant. •True diffusion coefficients may have low potential for the differentiation. •Perfusion fractions may be less specific parameter of diagnosis of pulmonary nodule. •Choice of b values shows little impact for differentiation of pulmonary nodules. -- Abstract: Objectives: To determine the appropriate parameters and evaluation method for characterizing solitary pulmonary nodules (SPNs) using quantitative parameters of diffusion-weighted imaging (DWI). Methods: Thirty-two subjects with 36 SPNs underwent DWI with seven different b values (0, 50, 100, 150, 300, 500, and 1000 s/mm 2 ). Five quantitative parameters were obtained from the region of interest drawn over each SPN: apparent diffusion coefficients (ADCs), true diffusion coefficients (DCs), and perfusion fractions (PFs), and signal–intensity ratios between lesion and spinal cord from DWI (b values: 1000 [LSR 1000 ] and 500 [LSR 500 )]). All quantitative parameters and the diagnostic capabilities were statistically compared. Results: SPNs were diagnosed as follow: malignant (n = 27) and benign (n = 9). Parameter comparisons for malignant and benign showed both LSRs differed significantly (p < 0.05). Applying feasible threshold values showed LSR 500 specificity (88.9% [8/9]) and accuracy (77.8% [28/36]) were significantly higher than ADC, DC, and PF specificity and accuracy (p < 0.05). LSR 1000 accuracy (72.2% [26/36]) was significantly higher than DC accuracy, and its specificity (88.9% [8/9]) was significantly higher than ADC, DC, and PF specificities (p < 0.05). Conclusions: For quantitative differentiation of SPNs, LSR evaluation was more useful and practical than ADC, DC, and PF, and choice of b values showed little impact for the differentiation

  13. Generalized Extreme Value's shape parameter and its nature for extreme precipitation using long time series and Bayesian approach

    Science.gov (United States)

    Ragulina, Galina; Reitan, Trond

    2016-04-01

    Assessing the probability of extreme precipitation events is of great importance in civil planning. This requires understanding of how return values change with different return periods, which is essentially described by the Generalized Extreme Value distribution's shape parameter. Some works in the field have suggested a constant shape parameter, while our analysis indicates a non-universal value. We first re-analyse an older precipitation dataset (169 stations) extended by Norwegian data (71 stations). We show that while each set seems to have a constant shape parameter, it differs between the two datasets, indicating regional differences. For a more comprehensive analysis of spatial effects, we examine a global dataset (1495 stations). We provide shape parameter maps for two models. We find clear evidence for the shape parameter being dependent on elevation while the effect of latitude remains uncertain. Our results confirm an explanation in terms of dominating precipitation systems based on a proxy derived from the Köppen-Geiger climate classification.

  14. Investigating Efficiency of Vector-Valued Intensity Measures in Seismic Demand Assessment of Concrete Dams

    Directory of Open Access Journals (Sweden)

    Mohammad Alembagheri

    2018-01-01

    Full Text Available The efficiency of vector-valued intensity measures for predicting the seismic demand in gravity dams is investigated. The Folsom gravity dam-reservoir coupled system is selected and numerically analyzed under a set of two-hundred actual ground motions. First, the well-defined scalar IMs are separately investigated, and then they are coupled to form two-parameter vector IMs. After that, IMs consisting of spectral acceleration at the first-mode natural period of the dam-reservoir system along with a measure of the spectral shape (the ratio of spectral acceleration at a second period to the first-mode spectral acceleration value are considered. It is attempted to determine the optimal second period by categorizing the spectral acceleration at the first-mode period of vibration. The efficiency of the proposed vector IMs is compared with scalar ones considering various structural responses as EDPs. Finally, the probabilistic seismic behavior of the dam is investigated by calculating its fragility curves employing scalar and vector IMs considering the effect of zero response values.

  15. A NEW METHOD TO QUANTIFY AND REDUCE THE NET PROJECTION ERROR IN WHOLE-SOLAR-ACTIVE-REGION PARAMETERS MEASURED FROM VECTOR MAGNETOGRAMS

    Energy Technology Data Exchange (ETDEWEB)

    Falconer, David A.; Tiwari, Sanjiv K.; Moore, Ronald L. [NASA Marshall Space Flight Center, Huntsville, AL 35812 (United States); Khazanov, Igor, E-mail: David.a.Falconer@nasa.gov [Center for Space Plasma and Aeronomic Research, University of Alabama in Huntsville, Huntsville, AL 35899 (United States)

    2016-12-20

    Projection errors limit the use of vector magnetograms of active regions (ARs) far from the disk center. In this Letter, for ARs observed up to 60° from the disk center, we demonstrate a method for measuring and reducing the projection error in the magnitude of any whole-AR parameter that is derived from a vector magnetogram that has been deprojected to the disk center. The method assumes that the center-to-limb curve of the average of the parameter’s absolute values, measured from the disk passage of a large number of ARs and normalized to each AR’s absolute value of the parameter at central meridian, gives the average fractional projection error at each radial distance from the disk center. To demonstrate the method, we use a large set of large-flux ARs and apply the method to a whole-AR parameter that is among the simplest to measure: whole-AR magnetic flux. We measure 30,845 SDO /Helioseismic and Magnetic Imager vector magnetograms covering the disk passage of 272 large-flux ARs, each having whole-AR flux >10{sup 22} Mx. We obtain the center-to-limb radial-distance run of the average projection error in measured whole-AR flux from a Chebyshev fit to the radial-distance plot of the 30,845 normalized measured values. The average projection error in the measured whole-AR flux of an AR at a given radial distance is removed by multiplying the measured flux by the correction factor given by the fit. The correction is important for both the study of the evolution of ARs and for improving the accuracy of forecasts of an AR’s major flare/coronal mass ejection productivity.

  16. Validity and repeatability of inertial measurement units for measuring gait parameters.

    Science.gov (United States)

    Washabaugh, Edward P; Kalyanaraman, Tarun; Adamczyk, Peter G; Claflin, Edward S; Krishnan, Chandramouli

    2017-06-01

    Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this study was to determine the validity and between-day repeatability of spatiotemporal metrics (gait speed, stance percent, swing percent, gait cycle time, stride length, cadence, and step duration) as measured with the APDM Opal IMUs and Mobility Lab system. We collected data on 39 healthy subjects. Subjects were tested over two days while walking on a standard treadmill, split-belt treadmill, or overground, with IMUs placed in two locations: both feet and both ankles. The spatiotemporal measurements taken with the IMU system were validated against data from an instrumented treadmill, or using standard clinical procedures. Repeatability and minimally detectable change (MDC) of the system was calculated between days. IMUs displayed high to moderate validity when measuring most of the gait metrics tested. Additionally, these measurements appear to be repeatable when used on the treadmill and overground. The foot configuration of the IMUs appeared to better measure gait parameters; however, both the foot and ankle configurations demonstrated good repeatability. In conclusion, the IMU system in this study appears to be both accurate and repeatable for measuring spatiotemporal gait parameters in healthy young adults. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Experimental Measures of Bus Comfort Levels Using Kinematic Parameters Recorded by Smartphone

    Energy Technology Data Exchange (ETDEWEB)

    Aquila, S. dell' ; Eboli, L.; Futia, G.; Mazzulla, G.; Pungillo, G.

    2016-07-01

    Comfort on board plays an essential role in the levels of satisfaction of a bus service perceived by passengers. The aim of this paper is to propose a measure of comfort based on two kinds of data: perceptions of passengers (subjective data) and accelerations of bus (objective data). For the collection of subjective data a questionnaire was addressed to a sample of university students, while a smartphone, equipped with GPS device and 3-axis accelerometer, was used to record the accelerations. Based on the recorded parameters, we determined the thresholds of the acceleration values beyond which the level of comfort cannot be considered as good.. (Author)

  18. Calculation of kinetic parameters of Caliban metallic core experimental reactor from stochastic neutron measurements

    Energy Technology Data Exchange (ETDEWEB)

    Casoli, P.; Authier, N.; Baud, J. [Commissariat a l' energie Atomique, Centre de Valduc, 21120 Is-sur-Tille (France)

    2009-07-01

    Several experimental devices are operated by the Criticality and Neutron Science Research Department of the CEA Valduc Laboratory. One of these is the metallic core reactor Caliban. The knowledge of the fundamental kinetic parameters of the reactor is very useful, indeed necessary, to the operator. The purpose of this study was to develop and perform experiments allowing to determinate some of these parameters. The prompt neutron decay constant and particularly its value at criticality can be measured with reactor noise techniques such as the interval-distribution, the Feynman variance-to-mean, and the Rossi-{alpha} methods. By introducing the Nelson number, the effective delayed neutron fraction and the average neutron lifetime can also be calculated with the Rossi-{alpha} method. Subcritical, critical, and even supercritical experiments were performed. With the Rossi-{alpha} technique, it was found that the prompt neutron decay constant at criticality was (6.02*10{sup 5} {+-} 9%). Experiments also brought out the limitations of the used experimental parameters. (authors)

  19. Measuring Parameters of Massive Black Hole Binaries with Partially Aligned Spins

    Science.gov (United States)

    Lang, Ryan N.; Hughes, Scott A.; Cornish, Neil J.

    2011-01-01

    The future space-based gravitational wave detector LISA will be able to measure parameters of coalescing massive black hole binaries, often to extremely high accuracy. Previous work has demonstrated that the black hole spins can have a strong impact on the accuracy of parameter measurement. Relativistic spin-induced precession modulates the waveform in a manner which can break degeneracies between parameters, in principle significantly improving how well they are measured. Recent studies have indicated, however, that spin precession may be weak for an important subset of astrophysical binary black holes: those in which the spins are aligned due to interactions with gas. In this paper, we examine how well a binary's parameters can be measured when its spins are partially aligned and compare results using waveforms that include higher post-Newtonian harmonics to those that are truncated at leading quadrupole order. We find that the weakened precession can substantially degrade parameter estimation, particularly for the "extrinsic" parameters sky position and distance. Absent higher harmonics, LISA typically localizes the sky position of a nearly aligned binary about an order of magnitude less accurately than one for which the spin orientations are random. Our knowledge of a source's sky position will thus be worst for the gas-rich systems which are most likely to produce electromagnetic counterparts. Fortunately, higher harmonics of the waveform can make up for this degradation. By including harmonics beyond the quadrupole in our waveform model, we find that the accuracy with which most of the binary's parameters are measured can be substantially improved. In some cases, the improvement is such that they are measured almost as well as when the binary spins are randomly aligned.

  20. Measurement-Based Transmission Line Parameter Estimation with Adaptive Data Selection Scheme

    DEFF Research Database (Denmark)

    Li, Changgang; Zhang, Yaping; Zhang, Hengxu

    2017-01-01

    Accurate parameters of transmission lines are critical for power system operation and control decision making. Transmission line parameter estimation based on measured data is an effective way to enhance the validity of the parameters. This paper proposes a multi-point transmission line parameter...

  1. Low-field NMR logging sensor for measuring hydraulic parameters of model soils

    Science.gov (United States)

    Sucre, Oscar; Pohlmeier, Andreas; Minière, Adrien; Blümich, Bernhard

    2011-08-01

    SummaryKnowing the exact hydraulic parameters of soils is very important for improving water management in agriculture and for the refinement of climate models. Up to now, however, the investigation of such parameters has required applying two techniques simultaneously which is time-consuming and invasive. Thus, the objective of this current study is to present only one technique, i.e., a new non-invasive method to measure hydraulic parameters of model soils by using low-field nuclear magnetic resonance (NMR). Hereby, two model clay or sandy soils were respectively filled in a 2 m-long acetate column having an integrated PVC tube. After the soils were completely saturated with water, a low-field NMR sensor was moved up and down in the PVC tube to quantitatively measure along the whole column the initial water content of each soil sample. Thereafter, both columns were allowed to drain. Meanwhile, the NMR sensor was set at a certain depth to measure the water content of that soil slice. Once the hydraulic equilibrium was reached in each of the two columns, a final moisture profile was taken along the whole column. Three curves were subsequently generated accordingly: (1) the initial moisture profile, (2) the evolution curve of the moisture depletion at that particular depth, and (3) the final moisture profile. All three curves were then inverse analyzed using a MATLAB code over numerical data produced with the van Genuchten-Mualem model. Hereby, a set of values ( α, n, θr and θs) was found for the hydraulic parameters for the soils under research. Additionally, the complete decaying NMR signal could be analyzed through Inverse Laplace Transformation and averaged on the 1/ T2 space. Through measurement of the decay in pure water, the effect on the relaxation caused by the sample could be estimated from the obtained spectra. The migration of the sample-related average with decreasing saturation speaks for a enhancement of the surface relaxation as the soil dries, in

  2. Potential Value of Coagulation Parameters for Suggesting Preeclampsia During the Third Trimester of Pregnancy.

    Science.gov (United States)

    Chen, Ying; Lin, Li

    2017-07-01

    Preeclampsia is a relatively common complication of pregnancy and considered to be associated with different degrees of coagulation dysfunction. This study was developed to evaluate the potential value of coagulation parameters for suggesting preeclampsia during the third trimester of pregnancy. Data from 188 healthy pregnant women, 125 patients with preeclampsia in the third trimester and 120 age-matched nonpregnant women were analyzed. Prothrombin time, prothrombin activity, activated partial thromboplastin time, fibrinogen (Fg), antithrombin, platelet count, mean platelet volume, platelet distribution width and plateletcrit were tested. All parameters, excluding prothrombin time, platelet distribution width and plateletcrit, differed significantly between healthy pregnant women and those with preeclampsia. Platelet count, antithrombin and Fg were significantly lower and mean platelet volume and prothrombin activity were significantly higher in patients with preeclampsia (P preeclampsia was 0.872 for Fg with an optimal cutoff value of ≤2.87g/L (sensitivity = 0.68 and specificity = 0.98). For severe preeclampsia, the area under the curve for Fg reached up to 0.922 with the same optimal cutoff value (sensitivity = 0.84, specificity = 0.98, positive predictive value = 0.96 and negative predictive value = 0.93). Fg is a biomarker suggestive of preeclampsia in the third trimester of pregnancy, and our data provide a potential cutoff value of Fg ≤ 2.87g/L for screening preeclampsia, especially severe preeclampsia. Copyright © 2017 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.

  3. Lattice-Valued Possibilistic Entropy Measure

    Czech Academy of Sciences Publication Activity Database

    Kramosil, Ivan

    2008-01-01

    Roč. 16, č. 6 (2008), s. 829-846 ISSN 0218-4885 R&D Projects: GA AV ČR IAA100300503 Institutional research plan: CEZ:AV0Z10300504 Keywords : complete lattice * lattice-valued possibilistic distribution * entropy measure * product of possibilistic distribution Subject RIV: BA - General Mathematics Impact factor: 1.000, year: 2008

  4. U-value measurements on a roof window

    DEFF Research Database (Denmark)

    Duer, Karsten

    1998-01-01

    This report describes the results of the U-value measurements performed on a roof window. The work is as a part of the development of an ISO/CEN standard measuring procedure for roof windows.The measurements have been performed using the procedures given in ISO 12567 draft version 1998...

  5. Bifurcation and Stability Analysis of the Equilibrium States in Thermodynamic Systems in a Small Vicinity of the Equilibrium Values of Parameters

    Science.gov (United States)

    Barsuk, Alexandr A.; Paladi, Florentin

    2018-04-01

    The dynamic behavior of thermodynamic system, described by one order parameter and one control parameter, in a small neighborhood of ordinary and bifurcation equilibrium values of the system parameters is studied. Using the general methods of investigating the branching (bifurcations) of solutions for nonlinear equations, we performed an exhaustive analysis of the order parameter dependences on the control parameter in a small vicinity of the equilibrium values of parameters, including the stability analysis of the equilibrium states, and the asymptotic behavior of the order parameter dependences on the control parameter (bifurcation diagrams). The peculiarities of the transition to an unstable state of the system are discussed, and the estimates of the transition time to the unstable state in the neighborhood of ordinary and bifurcation equilibrium values of parameters are given. The influence of an external field on the dynamic behavior of thermodynamic system is analyzed, and the peculiarities of the system dynamic behavior are discussed near the ordinary and bifurcation equilibrium values of parameters in the presence of external field. The dynamic process of magnetization of a ferromagnet is discussed by using the general methods of bifurcation and stability analysis presented in the paper.

  6. Correlations between skin hydration parameters and corneocyte-derived parameters to characterize skin conditions.

    Science.gov (United States)

    Masaki, Hitoshi; Yamashita, Yuki; Kyotani, Daiki; Honda, Tatsuya; Takano, Kenichi; Tamura, Toshiyasu; Mizutani, Taeko; Okano, Yuri

    2018-03-30

    Skin hydration is generally assessed using the parameters of skin surface water content (SWC) and trans-epidermal water loss (TEWL). To date, few studies have characterized skin conditions using correlations between skin hydration parameters and corneocyte parameters. The parameters SWC and TEWL allow the classification of skin conditions into four distinct Groups. The purpose of this study was to assess the characteristics of skin conditions classified by SWC and TEWL for correlations with parameters from corneocytes. A human volunteer test was conducted that measured SWC and TEWL. As corneocyte-derived parameters, the size and thick abrasion ratios, the ratio of sulfhydryl groups and disulfide bonds (SH/SS) and CP levels were analyzed. Volunteers were classified by their median SWC and TEWL values into 4 Groups: Group I (high SWC/low TEWL), Group II (high SWC/high TEWL), Group III (low SWC/low TEWL), and Group IV (low SWC/high TEWL). Group IV showed a significantly smaller size of corneocytes. Groups III and IV had significantly higher thick abrasion ratios and CP levels. Group I had a significantly lower SH/SS value. The SWC/TEWL value showed a decline in order from Group I to Group IV. Groups classified by their SWC and TEWL values showed characteristic skin conditions. We propose that the SWC and TEWL ratio is a comprehensive parameter to assess skin conditions. © 2018 Wiley Periodicals, Inc.

  7. On the audit of fair value measurements

    Directory of Open Access Journals (Sweden)

    Jatinder P. Singh

    2015-04-01

    Full Text Available In this article, the hypotheses „whether the auditor’s functional domain, his approach, methodology and responsibilities are undergoing a metamorphosis with the adoption of Fair Value Accounting (hereinafter the „FVA” and whether his/her role is moving away from the mechanized attester of tangible evidence to the one exercising a substantively judgmental function in a holistic assessment of the values ascribed to be fair by the entity’s management” are tested. These hypotheses are tested on the basis of an analysis of the statutory provisions, the pronouncements of accounting and other regulatory bodies and accounting norms and theories. After setting forth the research objectives and the hypotheses, the necessity of the FVA is reviewed and the underlying philosophy is analyzed. Impediments in performing audits of fair-value-based measurements are then identified and the US auditing standards and their international counterparts are touched upon. Finally, some safeguards and precautions for the auditor in an audit of fair-value measurements are presented.

  8. Study of electroweak parameters at LEP

    International Nuclear Information System (INIS)

    Blum, W.

    1991-10-01

    The measurement of the line shape and asymmetry parameters of the Z 0 in its leptonic and hadronic decays are reviewed. Progress is reported about a considerable increase in measurement accuracy. Several tests of the Standard Model confirm it to better than one per cent. New values for the effective mixing parameter are derived from the line shape parameters averaged over the four LEP experiments. The corresponding limits on the top mass are presented. (orig.)

  9. [Temporal and spatial heterogeneity analysis of optimal value of sensitive parameters in ecological process model: The BIOME-BGC model as an example.

    Science.gov (United States)

    Li, Yi Zhe; Zhang, Ting Long; Liu, Qiu Yu; Li, Ying

    2018-01-01

    The ecological process models are powerful tools for studying terrestrial ecosystem water and carbon cycle at present. However, there are many parameters for these models, and weather the reasonable values of these parameters were taken, have important impact on the models simulation results. In the past, the sensitivity and the optimization of model parameters were analyzed and discussed in many researches. But the temporal and spatial heterogeneity of the optimal parameters is less concerned. In this paper, the BIOME-BGC model was used as an example. In the evergreen broad-leaved forest, deciduous broad-leaved forest and C3 grassland, the sensitive parameters of the model were selected by constructing the sensitivity judgment index with two experimental sites selected under each vegetation type. The objective function was constructed by using the simulated annealing algorithm combined with the flux data to obtain the monthly optimal values of the sensitive parameters at each site. Then we constructed the temporal heterogeneity judgment index, the spatial heterogeneity judgment index and the temporal and spatial heterogeneity judgment index to quantitatively analyze the temporal and spatial heterogeneity of the optimal values of the model sensitive parameters. The results showed that the sensitivity of BIOME-BGC model parameters was different under different vegetation types, but the selected sensitive parameters were mostly consistent. The optimal values of the sensitive parameters of BIOME-BGC model mostly presented time-space heterogeneity to different degrees which varied with vegetation types. The sensitive parameters related to vegetation physiology and ecology had relatively little temporal and spatial heterogeneity while those related to environment and phenology had generally larger temporal and spatial heterogeneity. In addition, the temporal heterogeneity of the optimal values of the model sensitive parameters showed a significant linear correlation

  10. Retrievals of chlorine chemistry kinetic parameters from Antarctic ClO microwave radiometer measurements

    Directory of Open Access Journals (Sweden)

    S. Kremser

    2011-06-01

    Full Text Available Key kinetic parameters governing the partitioning of chlorine species in the Antarctic polar stratosphere were retrieved from 28 days of chlorine monoxide (ClO microwave radiometer measurements made during the late winter/early spring of 2005 at Scott Base (77.85° S, 166.75° E. During day-time the loss of the ClO dimer chlorine peroxide (ClOOCl occurs mainly by photolysis. Some time after sunrise, a photochemical equilibrium is established and the ClO/ClOOCl partitioning is determined by the ratio of the photolysis frequency, J, and the dimer formation rate, kf. The values of J and kf from laboratory studies remain uncertain to a considerable extent, and as a complement to these ongoing studies, the goal of this work is to provide a constraint on that uncertainty based on observations of ClO profiles in the Antarctic. First an optimal estimation technique was used to derive J/kf ratios for a range of Keq values. The optimal estimation forward model was a photochemical box model that takes J, kf, and Keq as inputs, together with a priori profiles of activated chlorine (ClOx = ClO+2×ClOOCl, profiles of ozone, temperature, and pressure. JPL06 kinetics are used as a priori in the optimal estimation and for all other chemistry in the forward model. Using the more recent JPL09 kinetics results in insignificant differences in the retrieved value of J/kf. A complementary approach was used to derive the optimal kinetic parameters; the full parameter space of J, kf, Keq and ClOx was sampled to find the minimum in differences between measured and modelled ClO profiles. Furthermore, values of Keq up to 2.0 times larger than recommended by JPL06 were explored to test the sensitivity of the

  11. VALUE AT RISK - CORPORATE RISK MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Anis Cecilia-Nicoleta

    2011-12-01

    Full Text Available The notion of 'risk' is used in a number of sciences. The Faculty of Law studies the risk depending on its legality. The Accident Theory applies this term to describe the damage and the disasters. One can find studies on the risks in the works of psychology, philosophy, medicine and within each of these areas the study of the risk is based on the given science subject and, of course, on their methods and approaches. Such a variety of risk study is explained by the diversity of this phenomenon. Under the market economy conditions, the risk is an essential component of any economic agent management policy, of the approach developed by this one, a strategy that depends almost entirely on individual ability and capacity to anticipate his evolution and to exploit his opportunities, assuming a so-called 'risk of business failure.' There are several ways to measure the risks in projects, one of the most used methods to measure this being the Value at Risk(VaR. Value at Risk (VaR was made famous by JP Morgan in the mid 1990s, by introducing the RiskMetrics approach, and hence, by far, has been sanctioned by several Governing Bodies throughout the world bank. In short, it measures the value of risk capital stocks in a given period at a certain probability of loss. This measurement can be modified for risk applications through, for example, the potential loss values affirmation in a certain amount of time during the economic life of the project- clearly, a project with a lower VaR is better. It should be noted that it is not always possible or advisable for a company to limit itself to the remote analysis of each risk because the risks and their effects are interdependent and constitute a system .In addition, there are risks which, in combination with other risks, tend to produce effects which they would not have caused by themselves and risks that tend to offset and even cancel each other out.

  12. Normative Values and Interrelationship of MDVP Voice Analysis Parameters Before and After Endotracheal Intubation

    DEFF Research Database (Denmark)

    Sørensen, Martin Kryspin; Durck, Tina Trier; Bork, Kristian

    2016-01-01

    normative values for adults and investigates the correlation between these MDVP parameters in relation to the "standardized" trauma of endotracheal intubation. METHODS: Preoperative and postoperative assessments of vocal fold pathology with flexible videolaryngoscopy and voice analysis with MDVP using...... the best-of-three standardized recording were performed in 121 patients with normal voices included consecutively in the RCT. The procedures of anesthesia were standardized. RESULTS: The normative MDVP values of this study are consistently lower compared with most normative values presented in other...... studies. The preoperative to postoperative differences in jitter values (jitter and relative average perturbation) were closely correlated to the shimmer values for patients with postoperative vocal fold edemas. In the patients with edema, the preoperative to postoperative differences in jitter had...

  13. Monte Carlo calculations and experimental measurements of dosimetric parameters of the IRA-103Pd source

    International Nuclear Information System (INIS)

    Sadeghi, Mahdi; Hosseini, Hamed; Raisali, Gholamreza

    2008-01-01

    Full text: The use of 103 Pd seed sources for permanent prostate implantation has become a popular brachytherapy application. As recommended by AAPM the dosimetric characteristics of the new source must be determined using experimental and Monte Carlo simulations, before its use in clinical applications thus The goal of this report is the experimental and theoretical determination of the dosimetric characteristics of this source following the recommendations in the AAPM TG-43U1 protocol. Figure 1 shows the geometry of the IRA- 103 Pd source. The source consists of a cylindrical silver core, 0.3 cm long x 0.05 cm in diameter, onto which 0.5 nm layer of 103 Pd has been uniformly adsorbed. The effective active length of source is 0.3 cm and the silver core encapsulated inside a hollow titanium tube with 0.45 cm long, 0.07 cm and 0.08 inner and outer diameters and two caps. The Monte Carlo N-Particle (MCNP) code, version 4C, was used to determine the relevant dosimetric parameters of the source. The geometry of the Monte Carlo simulation performed in this study consisted of a sphere with 30 cm diameter. Dose distributions around this source were measured in two Perspex phantom using enough TLD chips. For these measurements, slabs of Perspex material were machined to accommodate the source and TLD chips. A value of 0.67± 1% cGy.h -1 .U -1 for, Λ, was calculated as the ratio of d(r 0 ,θ 0 ) and s K , that may be compared with Λ values obtained for 103 Pd sources. Result of calculations and measurements values of dosimetric parameters of the source including radial dose function, g(r), and anisotropy function, F(r,θ), has been shown in separate figures. The radial dose function, g(r), for the IRA- 103 Pd source and other 103 Pd sources is included in Fig. 2. Comparison between measured and Monte Carlo simulated dose function, g(r), and anisotropy function, F(r,θ), of this source demonstrated that they are in good agreement with each other and The value of Λ is

  14. The effect of statistical analytical measurement variations on the plant control parameters and production costs in cement manufacturing – a case study

    Directory of Open Access Journals (Sweden)

    A. D. Love

    2010-01-01

    Full Text Available Raw materials used in cement manufacturing normally have varying chemical compositions and require regular analyses for plant control purposes. This is achieved by using several analytical instruments, such as XRF and ICP. The values obtained for the major elements Ca, Si, Fe and Al, are used to calculate the plant control parameters Lime Saturation Factor (LSF, Silica Ratio (SR and Alumina Modulus (AM. These plant control parameters are used to regulate the mixing and blending of various raw meal components and to operate the plant optimally. Any errors and large fluctuations in these plant parameters not only influence the quality of the cement produced, but also have a major effect on the cost of production of cement clinker through their influence on the energy consumption and residence time in the kiln. This paper looks at the role that statistical variances in the analytical measurements of the major elements Ca, Si, Fe and Al can have on the ultimate LSF, SR and AM values calculated from these measurements. The influence of too high and too low values of the LSF, SR and AM on clinker quality and energy consumption is discussed, and acceptable variances in these three parameters, based on plant experiences, are established. The effect of variances in the LSF, SR and AM parameters on the production costs is then analysed, and it is shown that variations of as large as 30% and as little as 5% can potentially occur. The LSF calculation incorporates most chemical elements and therefore is prone to the largest number of variations due to statistical variances in the analytical determinations of the chemical elements. Despite all these variations in LSF values they actually produced the smallest influence on the production cost of the clinker. It is therefore concluded that the LSF value is the most practical parameter for plant control purposes.

  15. Values of some topographic parameters of optic nerve head obtained by Heidelberg retina tomograph II in volunteers and different stage primary open-angle glaucoma patients

    Directory of Open Access Journals (Sweden)

    B. Anguelov

    2013-01-01

    Full Text Available Purpose: То assess the values of the top five topographic parameters of optic nerve head (ONH obtained by Heidelberg retina tomograph (HRT II in volunteers and primary open angle glaucoma (POAG patients with different stage of perimetric changes.Methods: 73 eyes (38 volunteers at the age of 56 years ±13, 11 men and 27 women and 170 eyes (90 patients at the age of 66 years ±12, 33 men and 57 women were examined. We performed the comprehensive ophthalmic examination, standard automated perimetry and measurement of the top five topographic parameters of ONH — rim area, rim volume, cup shape measure, height variation contour и mean RNFL thickness. For the purpose of this study we used HRT II.Results: We determine the values of the investigated topographic parameters of the ONH for healthy volunteers (rim area = 1.68±0.22 mm2, rim volume = 0.44±0.07 mm3, cup shape measure = –0.2±0.06, height variation contour = 0.38±0.08 mm and mean RNFL thickness = 0.24±0.03 mm and for the patients in different perimetric glaucoma stages (early stage: rim area = 1.52±0.47 mm2, rim volume = 0.38±0.17 mm3, cup shape measure = –0.14±0.1, height variation contour = 0.36±0.09 mm and mean RNFL thickness = 0.22±0.11 mm; moderate stage: rim area = 1.21±0.46 mm2, rim volume = 0.27±0.17 mm3, cup shape measure = –0.09±0.1, height variation contour = 0.36±0.17 mm and mean RNFL thickness = 0.16±0.12 mm; severe stage: rim area = 0.97±0.01 mm2, rim volume = 0.18±0.17 mm3, cup shape measure = –0.06±0.1, height variation contour = 0.28±0.11 mm and mean RNFL thickness = 0.17±0.11 mm. Hodapp-Parrish-Anderson (H-P-A ’s staging system includes three separate levels (early, moderate and severe of glaucoma according to visual field defects. Each stage is additionally characterized by the values of the top five topographic parameters of the ONH.Conclusion: Early diagnosis, staging and follow-up of POAG are based on both function and

  16. Complex Fuzzy Set-Valued Complex Fuzzy Measures and Their Properties

    Science.gov (United States)

    Ma, Shengquan; Li, Shenggang

    2014-01-01

    Let F*(K) be the set of all fuzzy complex numbers. In this paper some classical and measure-theoretical notions are extended to the case of complex fuzzy sets. They are fuzzy complex number-valued distance on F*(K), fuzzy complex number-valued measure on F*(K), and some related notions, such as null-additivity, pseudo-null-additivity, null-subtraction, pseudo-null-subtraction, autocontionuous from above, autocontionuous from below, and autocontinuity of the defined fuzzy complex number-valued measures. Properties of fuzzy complex number-valued measures are studied in detail. PMID:25093202

  17. Measurement of the Michel Parameters in Leptonic Tau Decays

    CERN Document Server

    Ackerstaff, K.; Allison, John; Altekamp, N.; Anderson, K.J.; Anderson, S.; Arcelli, S.; Asai, S.; Ashby, S.F.; Axen, D.; Azuelos, G.; Ball, A.H.; Barberio, E.; Barlow, Roger J.; Bartoldus, R.; Batley, J.R.; Baumann, S.; Bechtluft, J.; Behnke, T.; Bell, Kenneth Watson; Bella, G.; Bentvelsen, S.; Bethke, S.; Betts, S.; Biebel, O.; Biguzzi, A.; Bird, S.D.; Blobel, V.; Bloodworth, I.J.; Bobinski, M.; Bock, P.; Bohme, J.; Boutemeur, M.; Braibant, S.; Bright-Thomas, P.; Brown, Robert M.; Burckhart, H.J.; Burgard, C.; Burgin, R.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Chrisman, D.; Ciocca, C.; Clarke, P.E.L.; Clay, E.; Cohen, I.; Conboy, J.E.; Cooke, O.C.; Couyoumtzelis, C.; Coxe, R.L.; Cuffiani, M.; Dado, S.; Dallavalle, G.Marco; Davis, R.; De Jong, S.; del Pozo, L.A.; de Roeck, A.; Desch, K.; Dienes, B.; Dixit, M.S.; Doucet, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Eatough, D.; Estabrooks, P.G.; Etzion, E.; Evans, H.G.; Fabbri, F.; Fanfani, A.; Fanti, M.; Faust, A.A.; Fiedler, F.; Fierro, M.; Fischer, H.M.; Fleck, I.; Folman, R.; Furtjes, A.; Futyan, D.I.; Gagnon, P.; Gary, J.W.; Gascon, J.; Gascon-Shotkin, S.M.; Geich-Gimbel, C.; Geralis, T.; Giacomelli, G.; Giacomelli, P.; Gibson, V.; Gibson, W.R.; Gingrich, D.M.; Glenzinski, D.; Goldberg, J.; Gorn, W.; Grandi, C.; Gross, E.; Grunhaus, J.; Gruwe, M.; Hanson, G.G.; Hansroul, M.; Hapke, M.; Hargrove, C.K.; Hartmann, C.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Herndon, M.; Herten, G.; Heuer, R.D.; Hildreth, M.D.; Hill, J.C.; Hillier, S.J.; Hobson, P.R.; Hocker, James Andrew; Homer, R.J.; Honma, A.K.; Horvath, D.; Hossain, K.R.; Howard, R.; Huntemeyer, P.; Igo-Kemenes, P.; Imrie, D.C.; Ishii, K.; Jacob, F.R.; Jawahery, A.; Jeremie, H.; Jimack, M.; Joly, A.; Jones, C.R.; Jovanovic, P.; Junk, T.R.; Karlen, D.; Kartvelishvili, V.; Kawagoe, K.; Kawamoto, T.; Kayal, P.I.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Klier, A.; Kluth, S.; Kobayashi, T.; Kobel, M.; Koetke, D.S.; Kokott, T.P.; Kolrep, M.; Komamiya, S.; Kowalewski, Robert V.; Kress, T.; Krieger, P.; von Krogh, J.; Kyberd, P.; Lafferty, G.D.; Lanske, D.; Lauber, J.; Lautenschlager, S.R.; Lawson, I.; Layter, J.G.; Lazic, D.; Lee, A.M.; Lefebvre, E.; Lellouch, D.; Letts, J.; Levinson, L.; Liebisch, R.; List, B.; Littlewood, C.; Lloyd, A.W.; Lloyd, S.L.; Loebinger, F.K.; Long, G.D.; Losty, M.J.; Ludwig, J.; Lui, D.; Macchiolo, A.; Macpherson, A.; Mannelli, M.; Marcellini, S.; Markopoulos, C.; Martin, A.J.; Martin, J.P.; Martinez, G.; Mashimo, T.; Mattig, Peter; McDonald, W.John; McKenna, J.; Mckigney, E.A.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Menke, S.; Merritt, F.S.; Mes, H.; Meyer, J.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Mir, R.; Mohr, W.; Montanari, A.; Mori, T.; Nagai, K.; Nakamura, I.; Neal, H.A.; Nellen, B.; Nisius, R.; O'Neale, S.W.; Oakham, F.G.; Odorici, F.; Ogren, H.O.; Oreglia, M.J.; Orito, S.; Palinkas, J.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Patt, J.; Perez-Ochoa, R.; Petzold, S.; Pfeifenschneider, P.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poffenberger, P.; Poli, B.; Polok, J.; Przybycien, M.; Rembser, C.; Rick, H.; Robertson, S.; Robins, S.A.; Rodning, N.; Roney, J.M.; Roscoe, K.; Rossi, A.M.; Rozen, Y.; Runge, K.; Runolfsson, O.; Rust, D.R.; Sachs, K.; Saeki, T.; Sahr, O.; Sang, W.M.; Sarkisian, E.K.G.; Sbarra, C.; Schaile, A.D.; Schaile, O.; Scharf, F.; Scharff-Hansen, P.; Schieck, J.; Schmitt, B.; Schmitt, S.; Schoning, A.; Schorner, T.; Schroder, Matthias; Schumacher, M.; Schwick, C.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Shepherd-Themistocleous, C.H.; Sherwood, P.; Siroli, G.P.; Sittler, A.; Skuja, A.; Smith, A.M.; Snow, G.A.; Sobie, R.; Soldner-Rembold, S.; Sproston, M.; Stahl, A.; Stephens, K.; Steuerer, J.; Stoll, K.; Strom, David M.; Strohmer, R.; Tafirout, R.; Talbot, S.D.; Tanaka, S.; Taras, P.; Tarem, S.; Teuscher, R.; Thiergen, M.; Thomson, M.A.; von Torne, E.; Torrence, E.; Towers, S.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turcot, A.S.; Turner-Watson, M.F.; Van Kooten, Rick J.; Vannerem, P.; Verzocchi, M.; Vikas, P.; Voss, H.; Wackerle, F.; Wagner, A.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wermes, N.; White, J.S.; Wilson, G.W.; Wilson, J.A.; Wyatt, T.R.; Yamashita, S.; Yekutieli, G.; Zacek, V.; Zer-Zion, D.

    1999-01-01

    The Michel parameters of the leptonic tau decays are measured using the OPAL detector at LEP. The Michel parameters are extracted from the energy spectra of the charged decay leptons and from their energy-energy correlations. A new method involving a global likelihood fit of Monte Carlo generated events with complete detector simulation and background treatment has been applied to the data recorded at center-of-mass energies close to sqrt(s) = M(Z) corresponding to an integrated luminosity of 155 pb-1 during the years 1990 to 1995. If e-mu universality is assumed and inferring the tau polarization from neutral current data, the measured Michel parameters are extracted. Limits on non-standard coupling constants and on the masses of new gauge bosons are obtained. The results are in agreement with the V-A prediction of the Standard Model.

  18. Handbook of parameter values for the prediction of radionuclide transfer in temperate environments

    International Nuclear Information System (INIS)

    1994-01-01

    This Handbook has been prepared in response to a widely expressed interest in having a convenient and authoritative reference for radionuclide transfer parameter values used in biospheric assessment models. It draws on data from North America and Europe, much of which was collected through projects of the International Union of Radioecologists (IUR) and the Commission of European Communities (CEC) over the last decade. It is intended to supplement existing IAEA publications on environmental assessment methodology, primarily Generic Models and Parameters for Assessing the Environmental Transfer of Radionuclides from Routine Releases, IAEA Safety Series No. 57 (1982). 219 refs, 3 figs, 32 tabs

  19. Determination of cosmological parameters: An introduction for non ...

    Indian Academy of Sciences (India)

    Then I show how the age of the universe depends on them, followed by the evolution of the scale parameter of the universe for various values of the density parameters. Then I define strategies for measuring them, and show the results for the recent determination of these parameters from measurements on supernovas of ...

  20. Measuring the strategic value of information technology investments

    International Nuclear Information System (INIS)

    Conrad, K.W.

    1994-08-01

    Value is often perceived differently by the proponents of new information technologies and those who allocate resources and define priorities. Such differences often become a roadblock to meeting true business needs. Project justifications regularly rely on calculated cost savings, which rarely measure the full benefit of new technologies. In fact, if cost savings provide a complete picture, then the organization is probably just automating routine clerical operations and has abandoned efforts that would provide significant strategic value. Strategic value is not limited to financial calculations, but includes quality, time and risk criteria. This paper describes approaches for measuring strategic value that can provide organizations with proven techniques to improve performance, reengineer processes, benchmark performance against other suppliers, identify outsourcing opportunities, or defend themselves from pressures to outsource. Many organizations respond to tightening budgets by cutting overhead. These measurement approaches can demonstrate how overhead is critical to organizational effectiveness and how cost savings can be found, instead, by measurably improving performance throughout the organization. Finally, the paper describes efforts underway within the Department of Energy and at the Hanford Site to implement the approaches described in this paper

  1. Measuring the strategic value of information technology investments

    Energy Technology Data Exchange (ETDEWEB)

    Conrad, K.W. [Boeing Computer Services Co., Richland, WA (United States)

    1994-08-01

    Value is often perceived differently by the proponents of new information technologies and those who allocate resources and define priorities. Such differences often become a roadblock to meeting true business needs. Project justifications regularly rely on calculated cost savings, which rarely measure the full benefit of new technologies. In fact, if cost savings provide a complete picture, then the organization is probably just automating routine clerical operations and has abandoned efforts that would provide significant strategic value. Strategic value is not limited to financial calculations, but includes quality, time and risk criteria. This paper describes approaches for measuring strategic value that can provide organizations with proven techniques to improve performance, reengineer processes, benchmark performance against other suppliers, identify outsourcing opportunities, or defend themselves from pressures to outsource. Many organizations respond to tightening budgets by cutting overhead. These measurement approaches can demonstrate how overhead is critical to organizational effectiveness and how cost savings can be found, instead, by measurably improving performance throughout the organization. Finally, the paper describes efforts underway within the Department of Energy and at the Hanford Site to implement the approaches described in this paper.

  2. Historical Costs versus Fair Value Measurement in Financial Accounting

    OpenAIRE

    Dvořáková, Dana

    2009-01-01

    There are two important points in which in which we need assets and liabilities measured in financial accounting: on initial recognition and at a balance sheet day. Many International Financial Reporting Standards (IFRS) used the fair value measurement concept. But most of these standards use the fair value measurement method only at a balance sheet day. On initial recognition assets and liabilities are measured usually at costs. The IASB presented the discussion paper “Measurement Bases for ...

  3. Extreme value analysis of meteorological parameters observed during the period 1994-2001 at Kakrapar Atomic Power Station

    International Nuclear Information System (INIS)

    Ramkumar, S.; Dole, M.L.; Nankar, D.P.; Rajan, M.P.; Gurg, R.P.

    2003-01-01

    In the design of engineering structures, an understanding of extreme weather conditions that may occur at the site of interest is very essential, so that the structures can be designed to withstand such situations. In this report an analysis of extreme values of meteorological parameters observed at Kakrapar Atomic Power Station site for the period 1994 -2001 is described. The parameters considered are maximum and minimum air temperature, maximum wind speed and gust, and maximum rainfall in a month, in a day, in an hour and annual rainfall. The extreme value analysis reveals that annual rainfall, maximum monthly rainfall, minimum air temperature and maximum wind speed at 10 m obey Fisher-Tippet Type -1 distribution whereas maximum daily rainfall, maximum hourly rainfall, maxinlum air temperature and maximum wind speed at 30 m obey Fisher-Tippet Type -2 distribution function. There is no difference in correlation coefficients and fit both extreme value distribution function. Co-efficients of the distribution functions for each variable are established. Extreme values of parameters corresponding to return periods of 50 and 100 years are derived. These derived extreme values are particularly useful for arriving at suitable design basis values to ensure the safety of any civil structure in and around Kakrapar Atomic Power Station site with respect to stresses due to weather conditions. (author)

  4. Interpretation of acoustic parameters obtained by EMAR measurement for non-destructive hydrogen concentration measurement in Zr alloy

    International Nuclear Information System (INIS)

    Nakatsuka, Masafumi; Uchida, Katsuya; Miyazaki, Akihiro; Ishii, Yoshiaki

    2007-01-01

    An obvious quantitative relation between hydrogen concentrations in zirconium alloy and acoustic anisotropy parameters obtained by the electromagnetic acoustic resonance (EMAR) method was reported. To elucidate the mechanism, the acoustic parameters were calculated based on the elastic theory and the equation of motion. The acoustic parameters of obtained by the EMAR method were interpreted quantitatively using the anisotropic elastic constants of the specimen, and value calculated from texture data for non-hydrogen charged specimens showed good agreement with those obtained by the EMAR method. Calculated temperature dependence of the acoustic anisotropy for the non-hydrogen charged specimen also agreed well with that by the EMAR method. The consistencies demonstrated that the absolute values of the acoustic parameters for non-hydrogen charged specimen can be calculated from both the texture data of (0002) pole figure and the elastic constants of the specimen. Hydrogen addition up to approximately 650ppm was found not to change the original (0002) pole figure and, correspondingly, no hydrogen concentration dependence of the acoustic parameters was obtained from the calculation. These results implied that the zirconium hydride itself played an important role for the change in the acoustic parameters of the hydrogen charged specimens, and the importance of obtaining the information on the elastic constants of the zirconium hydride was pointed out. (author)

  5. Cloud and Thermodynamic Parameters Retrieved from Satellite Ultraspectral Infrared Measurements

    Science.gov (United States)

    Zhou, Daniel K.; Smith, William L.; Larar, Allen M.; Liu, Xu; Taylor, Jonathan P.; Schluessel, Peter; Strow, L. Larrabee; Mango, Stephen A.

    2008-01-01

    Atmospheric-thermodynamic parameters and surface properties are basic meteorological parameters for weather forecasting. A physical geophysical parameter retrieval scheme dealing with cloudy and cloud-free radiance observed with satellite ultraspectral infrared sounders has been developed and applied to the Infrared Atmospheric Sounding Interferometer (IASI) and the Atmospheric InfraRed Sounder (AIRS). The retrieved parameters presented herein are from radiance data gathered during the Joint Airborne IASI Validation Experiment (JAIVEx). JAIVEx provided intensive aircraft observations obtained from airborne Fourier Transform Spectrometer (FTS) systems, in-situ measurements, and dedicated dropsonde and radiosonde measurements for the validation of the IASI products. Here, IASI atmospheric profile retrievals are compared with those obtained from dedicated dropsondes, radiosondes, and the airborne FTS system. The IASI examples presented here demonstrate the ability to retrieve fine-scale horizontal features with high vertical resolution from satellite ultraspectral sounder radiance spectra.

  6. Relationship between lens density measurements by Pentacam Scheimpflug imaging and torsional phacoemulsification parameters

    Directory of Open Access Journals (Sweden)

    Suleyman Demircan

    2014-10-01

    Full Text Available AIM: To evaluate the relationship between the density values of the lens nucleus measured using Pentacam Scheimpflug imaging and torsional phacoemulsification dynamics such as the level of ultrasound energy, as well as the duration and amount of fluid used in patients with age-related nuclear cataract. METHODS: This was a prospective observer-masked study. Pentacam Scheimpflug imaging was performed following pupil dilation. The cataracts were automatically graded from 1 to 5 using pentacam nucleus densitometry(PND, also known as Pentacam nucleus staging(PNSsoftware by the same observer. After phacoemulsification, total Ultrasound(U/Stime, Cumulative dissipated energy(CDE, Torsional U/S time, and Estimated fluid use were automatically calculated and displayed on the monitor of Infiniti OZiL IP phacoemulsification system. One-way analysis of variance(ANOVAwas used to assess differences between groups. The Tamhane test was used for multiple group analysis. Spearman correlation analysis was used to assess the relationship between lens density measured by PND and the dynamics of torsional phacoemulsification. P0.05 was considered statistically significant. RESULTS:In the present study, 125 eyes from 125 patients were evaluated. Mean age was 69.7±9.4y(range: 48-88y, and 61 men and 64 women were included. The highest and lowest values of U/S total time, torsional U/S time, CDE, and Estimated fluid use were 0.70 - 158.90s, 0.70-158.50s, 0.11-42.65, and 21-98 mL in groups, respectively. Significant differences were found among PND groups. When the relationship between phacoemulsification dynamics and PND values were evaluated, there were significant correlations between PND value and total ultrasound time(r=0.767; Pr=0.767; Pr=0.758; Pr=0.602; PCONCLUSION:An objective degree of nucleus density obtained by PND scoring before cataract surgery may allow antecedent determination of intraoperative phacoemulsification parameters. Thus, individualized

  7. Geotechnical Parameters from Seismic Measurements: Two Field Examples from Egypt and Saudi Arabia

    KAUST Repository

    Khalil, Mohamed H.; Hanafy, Sherif M.

    2016-01-01

    © 2016 EEGS. Geotechnical parameters were used to determine subsurface rock quality for construction purposes. We summarize the mathematical relationships used to calculate the geotechnical parameters from P- and S-wave velocities and density values

  8. Phase Method of Invariant Measurement of Active-Inductive Measuring Two-Pole Parameters

    Directory of Open Access Journals (Sweden)

    Boris MAMIKONYAN

    2017-04-01

    Full Text Available There has been given the solution of the technical problem of separate measurement of parameters of inductance coils and inductive primary converters on alternating current without application of potential-current signals. As a measuring circuit the scheme of voltage divider with active-inductive two-pole is used, and as an output signal there has been used the angle of phase shift between two output voltages of the measuring circuit. For forming the output signal temporal separation of measurement channel is used. The advantages of phase method are mostly due to capacity of using microcontrollers. In the technical solutions under consideration the microcontroller regulates the measuring process and develops the measurement results.

  9. New Values of Cross-Talk Parameters for Twisted Pair Model

    OpenAIRE

    Milos Kozak; Lukas Cepa; Jiri Vodrazka

    2010-01-01

    Near-end Crosstalk (NEXT) and Far-end Crosstalk (FEXT) of unshielded twisted pair (UTP) cable are the main factors limiting the information capacity in data transmission. Crosstalk depends mostly on the frequency. Frequency dependent transfer functions and crosstalk attenuation may be obtained by measurement, but for the analytical description of the transmission channel's parameters is useful to define functions modelling the crosstalk. The paper describes the measuri...

  10. Are historical values of ionospheric parameters from ionosondes overestimated?

    Science.gov (United States)

    Laštovička, J.; Koucká Knížová, P.; Kouba, D.

    2012-04-01

    Ionogram-scaled values from pre-digital ionosonde times had been derived from ionograms under the assumption of the vertical reflection of ordinary mode of sounding radio waves. Classical ionosondes were unable to distinguish between the vertical and oblique reflections and in the case of the Es-layer also between the ordinary and extraordinary mode reflections due to mirror-like reflections. However, modern digisondes determine clearly the oblique or extraordinary mode reflections. Evaluating the Pruhonice digisonde ionograms in "classical" and in "correct" way we found for seven summers (2004-2010) that among strong foEs (> 6 MHz) only 10% of foEs values were correct and 90% were artificially enhanced in average by 1 MHz, in extreme cases by more than 3 MHz (some oblique reflections). 34% of all reflections were oblique reflections. With other ionospheric parameters like foF2 or foE the problem is less severe because non-mirror reflection makes delay of the extraordinary mode with respect to the ordinary mode and they are separated on ionograms, and oblique reflections are less frequent than with the patchy Es layer. At high latitudes another problem is caused by the z-mode, which is sometimes difficult to be distinguished from the ordinary mode.

  11. Measurements of Physical Parameters of White Dwarfs: A Test of the Mass–Radius Relation

    Energy Technology Data Exchange (ETDEWEB)

    Bédard, A.; Bergeron, P.; Fontaine, G., E-mail: bedard@astro.umontreal.ca, E-mail: bergeron@astro.umontreal.ca, E-mail: fontaine@astro.umontreal.ca [Département de Physique, Université de Montréal, C.P. 6128, Succ. Centre-Ville, Montréal, Québec H3C 3J7 (Canada)

    2017-10-10

    We present a detailed spectroscopic and photometric analysis of 219 DA and DB white dwarfs for which trigonometric parallax measurements are available. Our aim is to compare the physical parameters derived from the spectroscopic and photometric techniques, and then to test the theoretical mass–radius relation for white dwarfs using these results. The agreement between spectroscopic and photometric parameters is found to be excellent, especially for effective temperatures, showing that our model atmospheres and fitting procedures provide an accurate, internally consistent analysis. The values of surface gravity and solid angle obtained, respectively, from spectroscopy and photometry, are combined with parallax measurements in various ways to study the validity of the mass–radius relation from an empirical point of view. After a thorough examination of our results, we find that 73% and 92% of the white dwarfs are consistent within 1 σ and 2 σ confidence levels, respectively, with the predictions of the mass–radius relation, thus providing strong support to the theory of stellar degeneracy. Our analysis also allows us to identify 15 stars that are better interpreted in terms of unresolved double degenerate binaries. Atmospheric parameters for both components in these binary systems are obtained using a novel approach. We further identify a few white dwarfs that are possibly composed of an iron core rather than a carbon/oxygen core, since they are consistent with Fe-core evolutionary models.

  12. Offline analysis in SNLS: measurement of type-Ia supernovae explosion rate and cosmological parameters

    International Nuclear Information System (INIS)

    Lusset, Vincent

    2006-01-01

    The Supernova Legacy Survey is a second generation experiment for the measurement of cosmological parameters using type-la supernovae. Il follows the discovery of the acceleration of the expansion of the Universe, attributed to an unknown 'dark energy'. This thesis presents a type-la supernovae search using an offline analysis of SNLS data. It makes it possible to detect the supernovae that were missed online and to study possible selection biases. One of its principal characteristics is that it uses entirely automatic selection criteria. This type of automated offline analysis had never been carried out before for data reaching this redshift. This analysis enabled us to discover 73 additional SNIa candidates compared to those identified in the real time analysis on the same data, representing an increase of more than 50% of the number of supernovae. The final Hubble diagram contains 262 SNIa which gives us, for a flat ACDM model, the following values for the cosmological parameters: Ω_M = 0,31 ± 0,028 (stat) ± 0,036 (syst) et Ω_A = 0,69. This offline analysis of SNLS data opens new horizons, both by checking for possible biases in current measurements of cosmological parameters by supernovae experiments and by preparing the third generation experiments, on the ground or in space, which will detect thousands of SNIa. (author) [fr

  13. In vitro and in vivo measurements of the dissolution parameters of uranium and plutonium mixed oxides in biological environment

    International Nuclear Information System (INIS)

    Matton, S.

    1999-01-01

    During the mixed-oxide fuel fabrication process, inhalation is potentially the main route of internal contamination. The International Commission on Radiological Protection recommends experimental measurement of parameters such as size and dissolution rate for specific industrial compounds. First, we validated the use of PERALS (Photon Electron Rejecting Alpha Liquid Scintillation) for alpha measurement in biological samples which, in some cases, could improve detection limit. We characterised physical chemical properties in terms of size, specific area and activity of 3 different powders: MOX made according to either the MIMAS process, which showed heterogeneous chemical composition, or the SOLGEL, which showed homogeneous chemical composition and industrial PuO 2 . Their dissolution parameters, f r and s s , as defined in the simplest model proposed by ICRP 66 were measured in vivo, after inhalation in the rat, and in vitro. The statistical variation of these values were expressed as standard deviation. Moreover, in vitro studies demonstrated variation of the s s value depending on the duration of the incubation. We also developed methods to characterise interactions between UO 2 particles and phosphate ions which could be involved in the actinide toxicity. (author) [fr

  14. Measurement of agricultural parameters using wireless sensor network (WSN)

    Science.gov (United States)

    Guaña-Moya, Javier; Sánchez-Almeida, Tarquino; Salgado-Reyes, Nelson

    2018-04-01

    The technological advances have allowed to create new applications in telecommunications, applying low power and reduced costs in their equipment, thus achieving the evolution of new wireless networks or also denominated Wireless Sensor Network. These technologies allow the generation of measurements and analysis of environmental parameter data and soil. Precision agriculture requires parameters for the improvement of production, obtained through WSN technologies. This research analyzes the climatic requirements and soil parameters in a rose plantation in a greenhouse at an altitude of 3,100 meters above sea level. In the present investigation, maximum parameters were obtained in the production of roses, which are in the optimum range of production, whereas the minimum parameters of temperature, humidity and luminosity, evidenced that these parameters can damage the plants, since temperatures less than 10 °C slow down the growth of the plant and allow the proliferation of diseases and fungi.

  15. Positive solutions for a nonlinear periodic boundary-value problem with a parameter

    Directory of Open Access Journals (Sweden)

    Jingliang Qiu

    2012-08-01

    Full Text Available Using topological degree theory with a partially ordered structure of space, sufficient conditions for the existence and multiplicity of positive solutions for a second-order nonlinear periodic boundary-value problem are established. Inspired by ideas in Guo and Lakshmikantham [6], we study the dependence of positive periodic solutions as a parameter approaches infinity, $$ lim_{lambdao +infty}|x_{lambda}|=+infty,quadhbox{or}quad lim_{lambdao+infty}|x_{lambda}|=0. $$

  16. A comparison between two powder compaction parameters of plasticity: the effective medium A parameter and the Heckel 1/K parameter.

    Science.gov (United States)

    Mahmoodi, Foad; Klevan, Ingvild; Nordström, Josefina; Alderborn, Göran; Frenning, Göran

    2013-09-10

    The purpose of the research was to introduce a procedure to derive a powder compression parameter (EM A) representing particle yield stress using an effective medium equation and to compare the EM A parameter with the Heckel compression parameter (1/K). 16 pharmaceutical powders, including drugs and excipients, were compressed in a materials testing instrument and powder compression profiles were derived using the EM and Heckel equations. The compression profiles thus obtained could be sub-divided into regions among which one region was approximately linear and from this region, the compression parameters EM A and 1/K were calculated. A linear relationship between the EM A parameter and the 1/K parameter was obtained with a strong correlation. The slope of the plot was close to 1 (0.84) and the intercept of the plot was small in comparison to the range of parameter values obtained. The relationship between the theoretical EM A parameter and the 1/K parameter supports the interpretation of the empirical Heckel parameter as being a measure of yield stress. It is concluded that the combination of Heckel and EM equations represents a suitable procedure to derive a value of particle plasticity from powder compression data. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Model-independent measurement of mixing parameters in $D^0 \\to K_S^0 \\pi^+ \\pi^-$ decays

    CERN Document Server

    Aaij, Roel; Adeva, Bernardo; Adinolfi, Marco; Affolder, Anthony; Ajaltouni, Ziad; Akar, Simon; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio Augusto; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; An, Liupan; Anderlini, Lucio; Anderson, Jonathan; Andreassi, Guido; Andreotti, Mirco; Andrews, Jason; Appleby, Robert; Aquines Gutierrez, Osvaldo; Archilli, Flavio; d'Argent, Philippe; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Bachmann, Sebastian; Back, John; Badalov, Alexey; Baesso, Clarissa; Baldini, Wander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Batozskaya, Varvara; Battista, Vincenzo; Bay, Aurelio; Beaucourt, Leo; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Bel, Lennaert; Bellee, Violaine; Belloli, Nicoletta; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Benton, Jack; Berezhnoy, Alexander; Bernet, Roland; Bertolin, Alessandro; Bettler, Marc-Olivier; van Beuzekom, Martinus; Bien, Alexander; Bifani, Simone; Billoir, Pierre; Bird, Thomas; Birnkraut, Alex; Bizzeti, Andrea; Blake, Thomas; Blanc, Frédéric; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Borghi, Silvia; Borsato, Martino; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Braun, Svende; Britsch, Markward; Britton, Thomas; Brodzicka, Jolanta; Brook, Nicholas; Buchanan, Emma; Burr, Christopher; Bursche, Albert; Buytaert, Jan; Cadeddu, Sandro; Calabrese, Roberto; Calvi, Marta; Calvo Gomez, Miriam; Campana, Pierluigi; Campora Perez, Daniel; Capriotti, Lorenzo; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carniti, Paolo; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casse, Gianluigi; Cassina, Lorenzo; Castillo Garcia, Lucia; Cattaneo, Marco; Cauet, Christophe; Cavallero, Giovanni; Cenci, Riccardo; Charles, Matthew; Charpentier, Philippe; Chefdeville, Maximilien; Chen, Shanzhen; Cheung, Shu-Faye; Chiapolini, Nicola; Chrzaszcz, Marcin; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coco, Victor; Cogan, Julien; Cogneras, Eric; Cogoni, Violetta; Cojocariu, Lucian; Collazuol, Gianmaria; Collins, Paula; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coombes, Matthew; Coquereau, Samuel; Corti, Gloria; Corvo, Marco; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Crocombe, Andrew; Cruz Torres, Melissa Maria; Cunliffe, Samuel; Currie, Robert; D'Ambrosio, Carmelo; Dall'Occo, Elena; Dalseno, Jeremy; David, Pieter; Davis, Adam; De Aguiar Francisco, Oscar; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Simone, Patrizia; Dean, Cameron Thomas; Decamp, Daniel; Deckenhoff, Mirko; Del Buono, Luigi; Déléage, Nicolas; Demmer, Moritz; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Dey, Biplab; Di Canto, Angelo; Di Ruscio, Francesco; Dijkstra, Hans; Donleavy, Stephanie; Dordei, Francesca; Dorigo, Mirco; Dosil Suárez, Alvaro; Dossett, David; Dovbnya, Anatoliy; Dreimanis, Karlis; Dufour, Laurent; Dujany, Giulio; Dupertuis, Frederic; Durante, Paolo; Dzhelyadin, Rustem; Dziurda, Agnieszka; Dzyuba, Alexey; Easo, Sajan; Egede, Ulrik; Egorychev, Victor; Eidelman, Semen; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; El Rifai, Ibrahim; Elsasser, Christian; Ely, Scott; Esen, Sevda; Evans, Hannah Mary; Evans, Timothy; Falabella, Antonio; Färber, Christian; Farley, Nathanael; Farry, Stephen; Fay, Robert; Ferguson, Dianne; Fernandez Albor, Victor; Ferrari, Fabio; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fiore, Marco; Fiorini, Massimiliano; Firlej, Miroslaw; Fitzpatrick, Conor; Fiutowski, Tomasz; Fohl, Klaus; Fol, Philip; Fontana, Marianna; Fontanelli, Flavio; Forshaw, Dean Charles; Forty, Roger; Frank, Markus; Frei, Christoph; Frosini, Maddalena; Fu, Jinlin; Furfaro, Emiliano; Gallas Torreira, Abraham; Galli, Domenico; Gallorini, Stefano; Gambetta, Silvia; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; García Pardiñas, Julián; Garra Tico, Jordi; Garrido, Lluis; Gascon, David; Gaspar, Clara; Gauld, Rhorry; Gavardi, Laura; Gazzoni, Giulio; Gerick, David; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gianì, Sebastiana; Gibson, Valerie; Girard, Olivier Göran; Giubega, Lavinia-Helena; Gligorov, V.V.; Göbel, Carla; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gotti, Claudio; Grabalosa Gándara, Marc; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graverini, Elena; Graziani, Giacomo; Grecu, Alexandru; Greening, Edward; Gregson, Sam; Griffith, Peter; Grillo, Lucia; Grünberg, Oliver; Gui, Bin; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; Hadavizadeh, Thomas; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Haines, Susan; Hall, Samuel; Hamilton, Brian; Han, Xiaoxue; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; He, Jibo; Head, Timothy; Heijne, Veerle; Hennessy, Karol; Henrard, Pierre; Henry, Louis; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adlène; Hill, Donal; Hoballah, Mostafa; Hombach, Christoph; Hulsbergen, Wouter; Humair, Thibaud; Hussain, Nazim; Hutchcroft, David; Hynds, Daniel; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jaeger, Andreas; Jalocha, Pawel; Jans, Eddy; Jawahery, Abolhassan; Jing, Fanfan; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Jurik, Nathan; Kandybei, Sergii; Kanso, Walaa; Karacson, Matthias; Karbach, Moritz; Karodia, Sarah; Kecke, Matthieu; Kelsey, Matthew; Kenyon, Ian; Kenzie, Matthew; Ketel, Tjeerd; Khairullin, Egor; Khanji, Basem; Khurewathanakul, Chitsanu; Klaver, Suzanne; Klimaszewski, Konrad; Kochebina, Olga; Kolpin, Michael; Komarov, Ilya; Koopman, Rose; Koppenburg, Patrick; Kozeiha, Mohamad; Kravchuk, Leonid; Kreplin, Katharina; Kreps, Michal; Krocker, Georg; Krokovny, Pavel; Kruse, Florian; Krzemien, Wojciech; Kucewicz, Wojciech; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kuonen, Axel Kevin; Kurek, Krzysztof; Kvaratskheliya, Tengiz; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lambert, Dean; Lanfranchi, Gaia; Langenbruch, Christoph; Langhans, Benedikt; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Lees, Jean-Pierre; Lefèvre, Regis; Leflat, Alexander; Lefrançois, Jacques; Lemos Cid, Edgar; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Yiming; Likhomanenko, Tatiana; Liles, Myfanwy; Lindner, Rolf; Linn, Christian; Lionetto, Federica; Liu, Bo; Liu, Xuesong; Loh, David; Longstaff, Iain; Lopes, Jose; Lucchesi, Donatella; Lucio Martinez, Miriam; Luo, Haofei; Lupato, Anna; Luppi, Eleonora; Lupton, Oliver; Lusiani, Alberto; Machefert, Frederic; Maciuc, Florin; Maev, Oleg; Maguire, Kevin; Malde, Sneha; Malinin, Alexander; Manca, Giulia; Mancinelli, Giampiero; Manning, Peter Michael; Mapelli, Alessandro; Maratas, Jan; Marchand, Jean François; Marconi, Umberto; Marin Benito, Carla; Marino, Pietro; Marks, Jörg; Martellotti, Giuseppe; Martin, Morgan; Martinelli, Maurizio; Martinez Santos, Diego; Martinez Vidal, Fernando; Martins Tostes, Danielle; Massafferri, André; Matev, Rosen; Mathad, Abhijit; Mathe, Zoltan; Matteuzzi, Clara; Mauri, Andrea; Maurin, Brice; Mazurov, Alexander; McCann, Michael; McCarthy, James; McNab, Andrew; McNulty, Ronan; Meadows, Brian; Meier, Frank; Meissner, Marco; Melnychuk, Dmytro; Merk, Marcel; Michielin, Emanuele; Milanes, Diego Alejandro; Minard, Marie-Noelle; Mitzel, Dominik Stefan; Molina Rodriguez, Josue; Monroy, Ignacio Alberto; Monteil, Stephane; Morandin, Mauro; Morawski, Piotr; Mordà, Alessandro; Morello, Michael Joseph; Moron, Jakub; Morris, Adam Benjamin; Mountain, Raymond; Muheim, Franz; Müller, Dominik; Müller, Janine; Müller, Katharina; Müller, Vanessa; Mussini, Manuel; Muster, Bastien; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nandi, Anita; Nasteva, Irina; Needham, Matthew; Neri, Nicola; Neubert, Sebastian; Neufeld, Niko; Neuner, Max; Nguyen, Anh Duc; Nguyen, Thi-Dung; Nguyen-Mau, Chung; Niess, Valentin; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Novoselov, Alexey; O'Hanlon, Daniel Patrick; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Ogilvy, Stephen; Okhrimenko, Oleksandr; Oldeman, Rudolf; Onderwater, Gerco; Osorio Rodrigues, Bruno; Otalora Goicochea, Juan Martin; Otto, Adam; Owen, Patrick; Oyanguren, Maria Aranzazu; Palano, Antimo; Palombo, Fernando; Palutan, Matteo; Panman, Jacob; Papanestis, Antonios; Pappagallo, Marco; Pappalardo, Luciano; Pappenheimer, Cheryl; Parker, William; Parkes, Christopher; Passaleva, Giovanni; Patel, Girish; Patel, Mitesh; Patrignani, Claudia; Pearce, Alex; Pellegrino, Antonio; Penso, Gianni; Pepe Altarelli, Monica; Perazzini, Stefano; Perret, Pascal; Pescatore, Luca; Petridis, Konstantinos; Petrolini, Alessandro; Petruzzo, Marco; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pilař, Tomas; Pinci, Davide; Pistone, Alessandro; Piucci, Alessio; Playfer, Stephen; Plo Casasus, Maximo; Poikela, Tuomas; Polci, Francesco; Poluektov, Anton; Polyakov, Ivan; Polycarpo, Erica; Popov, Alexander; Popov, Dmitry; Popovici, Bogdan; Potterat, Cédric; Price, Eugenia; Price, Joseph David; Prisciandaro, Jessica; Pritchard, Adrian; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Punzi, Giovanni; Qian, Wenbin; Quagliani, Renato; Rachwal, Bartolomiej; Rademacker, Jonas; Rama, Matteo; Rangel, Murilo; Raniuk, Iurii; Rauschmayr, Nathalie; Raven, Gerhard; Redi, Federico; Reichert, Stefanie; Reid, Matthew; dos Reis, Alberto; Ricciardi, Stefania; Richards, Sophie; Rihl, Mariana; Rinnert, Kurt; Rives Molina, Vincente; Robbe, Patrick; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Lopez, Jairo Alexis; Rodriguez Perez, Pablo; Roiser, Stefan; Romanovsky, Vladimir; Romero Vidal, Antonio; Ronayne, John William; Rotondo, Marcello; Rouvinet, Julien; Ruf, Thomas; Ruiz Valls, Pablo; Saborido Silva, Juan Jose; Sagidova, Naylya; Sail, Paul; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanchez Mayordomo, Carlos; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santimaria, Marco; Santovetti, Emanuele; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Saunders, Daniel Martin; Savrina, Darya; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmelzer, Timon; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schubiger, Maxime; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Semennikov, Alexander; Serra, Nicola; Serrano, Justine; Sestini, Lorenzo; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Vladimir; Shires, Alexander; Siddi, Benedetto Gianluca; Silva Coutinho, Rafael; Silva de Oliveira, Luiz Gustavo; Simi, Gabriele; Sirendi, Marek; Skidmore, Nicola; Skwarnicki, Tomasz; Smith, Edmund; Smith, Eluned; Smith, Iwan Thomas; Smith, Jackson; Smith, Mark; Snoek, Hella; Sokoloff, Michael; Soler, Paul; Soomro, Fatima; Souza, Daniel; Souza De Paula, Bruno; Spaan, Bernhard; Spradlin, Patrick; Sridharan, Srikanth; Stagni, Federico; Stahl, Marian; Stahl, Sascha; Stefkova, Slavorima; Steinkamp, Olaf; Stenyakin, Oleg; Stevenson, Scott; Stoica, Sabin; Stone, Sheldon; Storaci, Barbara; Stracka, Simone; Straticiuc, Mihai; Straumann, Ulrich; Sun, Liang; Sutcliffe, William; Swientek, Krzysztof; Swientek, Stefan; Syropoulos, Vasileios; Szczekowski, Marek; Szumlak, Tomasz; T'Jampens, Stephane; Tayduganov, Andrey; Tekampe, Tobias; Teklishyn, Maksym; Tellarini, Giulia; Teubert, Frederic; Thomas, Christopher; Thomas, Eric; van Tilburg, Jeroen; Tisserand, Vincent; Tobin, Mark; Todd, Jacob; Tolk, Siim; Tomassetti, Luca; Tonelli, Diego; Topp-Joergensen, Stig; Torr, Nicholas; Tournefier, Edwige; Tourneur, Stephane; Trabelsi, Karim; Tran, Minh Tâm; Tresch, Marco; Trisovic, Ana; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tuning, Niels; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vacca, Claudia; Vagnoni, Vincenzo; Valenti, Giovanni; Vallier, Alexis; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vázquez Sierra, Carlos; Vecchi, Stefania; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Vesterinen, Mika; Viaud, Benoit; Vieira, Daniel; Vieites Diaz, Maria; Vilasis-Cardona, Xavier; Volkov, Vladimir; Vollhardt, Achim; Volyanskyy, Dmytro; Voong, David; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; de Vries, Jacco; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Walsh, John; Wandernoth, Sebastian; Wang, Jianchun; Ward, David; Watson, Nigel; Websdale, David; Weiden, Andreas; Whitehead, Mark; Wilkinson, Guy; Wilkinson, Michael; Williams, Mark Richard James; Williams, Matthew; Williams, Mike; Williams, Timothy; Wilson, Fergus; Wimberley, Jack; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wyllie, Kenneth; Xie, Yuehong; Xu, Zhirui; Yang, Zhenwei; Yu, Jiesheng; Yuan, Xuhao; Yushchenko, Oleg; Zangoli, Maria; Zavertyaev, Mikhail; Zhang, Liming; Zhang, Yanxi; Zhelezov, Alexey; Zhokhov, Anatoly; Zhong, Liang; Zucchelli, Stefano

    2016-04-06

    The first model-independent measurement of the charm mixing parameters in the decay $D^0 \\to K_S \\pi^+ \\pi^-$ is reported, using a sample of $pp$ collision data recorded by the LHCb experiment, corresponding to an integrated luminosity of 1.0 fb$^{-1}$ at a centre-of-mass energy of 7 TeV. The measured values are \\begin{eqnarray*} x &=& ( -0.86 \\pm 0.53 \\pm 0.17 ) \\times 10^{-2}, \\\\ y &=& ( +0.03 \\pm 0.46 \\pm 0.13 ) \\times 10^{-2}, \\end{eqnarray*} where the first uncertainties are statistical and include small contributions due to the external input for the strong phase measured by the CLEO collaboration, and the second uncertainties are systematic.

  18. Geoelectrical Measurement of Multi-Scale Mass Transfer Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Day-Lewis, Frederick; Singha, Kamini; Haggerty, Roy; Johnson, Tim; Binley, Andrew; Lane, John

    2014-01-16

    Mass transfer affects contaminant transport and is thought to control the efficiency of aquifer remediation at a number of sites within the Department of Energy (DOE) complex. An improved understanding of mass transfer is critical to meeting the enormous scientific and engineering challenges currently facing DOE. Informed design of site remedies and long-term stewardship of radionuclide-contaminated sites will require new cost-effective laboratory and field techniques to measure the parameters controlling mass transfer spatially and across a range of scales. In this project, we sought to capitalize on the geophysical signatures of mass transfer. Previous numerical modeling and pilot-scale field experiments suggested that mass transfer produces a geoelectrical signature—a hysteretic relation between sampled (mobile-domain) fluid conductivity and bulk (mobile + immobile) conductivity—over a range of scales relevant to aquifer remediation. In this work, we investigated the geoelectrical signature of mass transfer during tracer transport in a series of controlled experiments to determine the operation of controlling parameters, and also investigated the use of complex-resistivity (CR) as a means of quantifying mass transfer parameters in situ without tracer experiments. In an add-on component to our grant, we additionally considered nuclear magnetic resonance (NMR) to help parse mobile from immobile porosities. Including the NMR component, our revised study objectives were to: 1. Develop and demonstrate geophysical approaches to measure mass-transfer parameters spatially and over a range of scales, including the combination of electrical resistivity monitoring, tracer tests, complex resistivity, nuclear magnetic resonance, and materials characterization; and 2. Provide mass-transfer estimates for improved understanding of contaminant fate and transport at DOE sites, such as uranium transport at the Hanford 300 Area. To achieve our objectives, we implemented a 3

  19. Pose measurement method with six parameters for microassembly based on an optical micrometer

    Science.gov (United States)

    Ye, Xin; Wang, Qiang; Zhang, Zhi-jing; Sun, Yuan; Zhang, Xiao-feng

    2009-07-01

    This paper presents a new pose measurement method of microminiature parts that is capable of transforming one dimension (1D) contour size obtained by optical micrometer to three dimension (3D) data with six parameters for microassembly. Pose measurement is one of the most important processes for microminiature parts' alignment and insertion in microassembly. During the past few years, researchers have developed their microassembly systems focusing on visual identification to obtain two or three dimension data with no more than three parameters. Scanning electronic microscope (SEM), optical microscope, and stereomicroscope are applied in their systems. However, as structures of microminiature parts become increasingly complex, six parameters to represent their position and orientation are specifically needed. Firstly, The pose measurement model is established based on the introduction of measuring objects and measuring principle of optical micrometer. The measuring objects are microminiature parts with complex 3D structure. Two groups of two dimension (2D) data are gathered at two different measurement positions. Then part pose with 6 parameters is calculated, including 3 position parameters of feature point of the part and 3 orientation parameters of the part axis. Secondly, pose measurement process for a small shaft, vertical orientation determination, and position parameters obtaining are presented. 2D data is gathered by scanning the generatrix of the part, and valid data is extracted and saved in arrays. A vertical orientation criterion is proposed to determine whether the part is parallel to the Z-axis of the coordinate. If not, 2D data will be fixed into a linear equation using least square algorithm. Then orientation parameters are calculated. Center of Part End (CPE) is selected as feature point of the part, and its position parameters are extracted form two group of 2D data. Finally, a fast pose measurement device is developed and representative

  20. Preparation of a tritium Q-value measurement in a double penning trap

    Energy Technology Data Exchange (ETDEWEB)

    Diehl, Christoph; Orth, Christoph; Blaum, Klaus [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Physikalisches Institut, Ruprecht-Karls-Universitaet, Heidelberg (Germany); Pinegar, David [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Van Dyck, Robert Jr. [Department of Physics, University of Washington, Seattle (United States)

    2009-07-01

    A precise determination of the Q-value of tritium ({sup 3}H) is of relevance for the determination of the electron anti-neutrino mass as aspired by the Karlsruhe Tritium Neutrino Experiment (KATRIN). In our double Penning trap mass spectrometer we aim to measure the mass ratio of {sup 3}H and its {beta}-decay product {sup 3}He to an accuracy of 10{sup -11}, which would determine the Q-value to an accuracy of 30 meV. The spectrometer we utilize is an enhanced version of the University of Washington Penning trap mass spectrometer (UW-PTMS) and was recently transfered from Seattle to Heidelberg, where it is set up at the moment as the MPIK/UW-PTMS. We present the necessary preparation work at the Max-Planck-Institut fuer Kernphysik. This includes major reconstructions of the building as well as studies and control of environmental parameters in the laboratory, like temperature and magnetic field.

  1. Neutron Capture and Transmission Measurements and Resonance Parameter Analysis of Samarium

    International Nuclear Information System (INIS)

    Leinweber, G.; Burke, J.A.; Knox, H.D.; Drindak, N.J.; Mesh, D.W.; Haines, W.T.; Ballad, R.V.; Block, R.C.; Slovacek, R.E.; Werner, C.J.; Trbovich, M.J.; Barry, D.P.; Sato, T.

    2001-01-01

    The purpose of the present work is to accurately measure the neutron cross sections of samarium. The most significant isotope is 149 Sm, which has a large neutron absorption cross section at thermal energies and is a 235 U fission product with a 1% yield. Its cross sections are thus of concern to reactor neutronics. Neutron capture and transmission measurements were performed by the time-of-flight technique at the Rensselaer Polytechnic institute (RPI) LINAC facility using metallic and liquid Sm samples. The capture measurements were made at the 25 meter flight station with a multiplicity-type capture detector, and the transmission total cross-section measurements were performed at 15- and 25-meter flight stations with 6 Li glass scintillation detectors. Resonance parameters were determined by a combined analysis of six experiments (three capture and three transmission) using the multi-level R-matrix Bayesian code SAMMY version M2. The significant features of this work are as follows. Dilute samples of samarium nitrate in deuterated water (D 2 O) were prepared to measure the strong resonances at 0.1 and 8 eV without saturation. Disk-shaped spectroscopic quartz cells were obtained with parallel inner surfaces to provide a uniform thickness of solution. The diluent feature of the SAMMY program was used to analyze these data. The SAMMY program also includes multiple scattering corrections to capture yield data and resolution functions specific to the RPI facility. Resonance parameters for all stable isotopes of samarium were deduced for all resonances up to 30 eV. Thermal capture cross-section and capture resonance integral calculations were made using the resultant resonance parameters and were compared to results obtained using resonance parameters from ENDF/B-VI updated through release 3. Extending the definition of the capture resonance integral to include the strong 0.1 eV resonance in 149 Sm, present measurements agree within estimated uncertainties with En

  2. A nuclear radiation multi-parameter measurement system based on pulse-shape sampling

    International Nuclear Information System (INIS)

    Qiu Xiaolin; Fang Guoming; Xu Peng; Di Yuming

    2007-01-01

    In this paper, A nuclear radiation multi-parameter measurement system based on pulse-shape sampling is introduced, including the system's characteristics, composition, operating principle, experiment data and analysis. Compared with conventional nuclear measuring apparatus, it has some remarkable advantages such as the synchronous detection using multi-parameter measurement in the same measurement platform and the general analysis of signal data by user-defined program. (authors)

  3. Statistics of Parameter Estimates: A Concrete Example

    KAUST Repository

    Aguilar, Oscar; Allmaras, Moritz; Bangerth, Wolfgang; Tenorio, Luis

    2015-01-01

    © 2015 Society for Industrial and Applied Mathematics. Most mathematical models include parameters that need to be determined from measurements. The estimated values of these parameters and their uncertainties depend on assumptions made about noise

  4. Definition and measurement of statistical gloss parameters from curved objects

    Energy Technology Data Exchange (ETDEWEB)

    Kuivalainen, Kalle; Oksman, Antti; Peiponen, Kai-Erik

    2010-09-20

    Gloss standards are commonly defined for gloss measurement from flat surfaces, and, accordingly, glossmeters are typically developed for flat objects. However, gloss inspection of convex, concave, and small products is also important. In this paper, we define statistical gloss parameters for curved objects and measure gloss data on convex and concave surfaces using two different diffractive-optical-element-based glossmeters. Examples of measurements with the two diffractive-optical-element-based glossmeters are given for convex and concave aluminum pipe samples with and without paint. The defined gloss parameters for curved objects are useful in the characterization of the surface quality of metal pipes and other objects.

  5. Definition and measurement of statistical gloss parameters from curved objects

    International Nuclear Information System (INIS)

    Kuivalainen, Kalle; Oksman, Antti; Peiponen, Kai-Erik

    2010-01-01

    Gloss standards are commonly defined for gloss measurement from flat surfaces, and, accordingly, glossmeters are typically developed for flat objects. However, gloss inspection of convex, concave, and small products is also important. In this paper, we define statistical gloss parameters for curved objects and measure gloss data on convex and concave surfaces using two different diffractive-optical-element-based glossmeters. Examples of measurements with the two diffractive-optical-element-based glossmeters are given for convex and concave aluminum pipe samples with and without paint. The defined gloss parameters for curved objects are useful in the characterization of the surface quality of metal pipes and other objects.

  6. Probabilistic teleportation via multi-parameter measurements and partially entangled states

    Science.gov (United States)

    Wei, Jiahua; Shi, Lei; Han, Chen; Xu, Zhiyan; Zhu, Yu; Wang, Gang; Wu, Hao

    2018-04-01

    In this paper, a novel scheme for probabilistic teleportation is presented with multi-parameter measurements via a non-maximally entangled state. This is in contrast to the fact that the measurement kinds for quantum teleportation are usually particular in most previous schemes. The detail implementation producers for our proposal are given by using of appropriate local unitary operations. Moreover, the total success probability and classical information of this proposal are calculated. It is demonstrated that the success probability and classical cost would be changed with the multi-measurement parameters and the entanglement factor of quantum channel. Our scheme could enlarge the research range of probabilistic teleportation.

  7. Estimation of inflation parameters for Perturbed Power Law model using recent CMB measurements

    International Nuclear Information System (INIS)

    Mukherjee, Suvodip; Das, Santanu; Souradeep, Tarun; Joy, Minu

    2015-01-01

    Cosmic Microwave Background (CMB) is an important probe for understanding the inflationary era of the Universe. We consider the Perturbed Power Law (PPL) model of inflation which is a soft deviation from Power Law (PL) inflationary model. This model captures the effect of higher order derivative of Hubble parameter during inflation, which in turn leads to a non-zero effective mass m eff for the inflaton field. The higher order derivatives of Hubble parameter at leading order sources constant difference in the spectral index for scalar and tensor perturbation going beyond PL model of inflation. PPL model have two observable independent parameters, namely spectral index for tensor perturbation ν t and change in spectral index for scalar perturbation ν st to explain the observed features in the scalar and tensor power spectrum of perturbation. From the recent measurements of CMB power spectra by WMAP, Planck and BICEP-2 for temperature and polarization, we estimate the feasibility of PPL model with standard ΛCDM model. Although BICEP-2 claimed a detection of r=0.2, estimates of dust contamination provided by Planck have left open the possibility that only upper bound on r will be expected in a joint analysis. As a result we consider different upper bounds on the value of r and show that PPL model can explain a lower value of tensor to scalar ratio (r<0.1 or r<0.01) for a scalar spectral index of n s =0.96 by having a non-zero value of effective mass of the inflaton field m 2 eff /H 2 . The analysis with WP + Planck likelihood shows a non-zero detection of m 2 eff /H 2 with 5.7 σ and 8.1 σ respectively for r<0.1 and r<0.01. Whereas, with BICEP-2 likelihood m 2 eff /H 2  = −0.0237 ± 0.0135 which is consistent with zero

  8. Recommendations for Measuring Tennis Racket Parameters

    Directory of Open Access Journals (Sweden)

    Tom Allen

    2018-02-01

    Full Text Available Tennis rackets have advanced significantly since the invention of the game in 1874, including innovations in both shape and materials. Advances in these design parameters have implications for racket performance, especially swing speed. This study tested one hundred rackets, spanning brands and eras, using simple, portable instruments in order to pilot protocols and make recommendations for streamlining testing procedures for tennis rackets. A wide range of properties were measured and documented for each racket. We suggest that since Transverse and Lateral Moment of Inertia are well correlated, measuring both is not necessary when processing a large number of rackets. In addition, it is also possible to predict the Transverse Moment of Inertia well from models that use simple dimension and mass measurements, which may be preferable in larger studies. Exploring the use of more complex modelling will allow us to better understand the impact of tennis racket design on performance in the future.

  9. INFLUENCE OF ROLLING STOCK VIBROACOUSTICAL PARAMETERS ON THE CHOICE OF RATIONAL VALUES OF LOCOMOTIVE RUNNING GEAR

    Directory of Open Access Journals (Sweden)

    Yu. V. Zelenko

    2016-06-01

    Full Text Available Purpose.The success of the traffic on the railways of Ukraine depends on the number and the operational fleet of electric locomotives. Today, the locomotive depot exploit physically and morally outdated locomotives that have low reliability. Modernization of electric locomotives is not economically justified. The aim of this study is to improve the safety of the traction rolling stock by the frequency analysis of dynamical systems, which allows conducting the calculation of the natural (of resonant frequencies of the design and related forms of vibrations.Methodology.The study was conducted by methods of analytical mechanics and mathematical modeling of operating loads of freight locomotive when driving at different speeds on the straight and curved track sections. The theoretical value of the work is the technique of choice of constructive schemes and rational parameters of perspective electric locomotive taking into account the electric inertia ratios and stiffness coefficients of Lagrange second-order equations.Findings. The problems of theoretical research and the development of a mathematical model of the spatial electric vibrations are solved. The theoretical studies of the effect of inertia ratios and stiffness coefficients on the dynamic values and the parameter values of electric locomotive undercarriages are presented.Originality.The set of developed regulations and obtained results is a practical solution to selecting rational parameters of bogies of the freight mainline locomotive for railways of Ukraine. A concept of choice of constructive scheme and rational parameters of perspective locomotive is formulated. It is developed the method of calculation of spatial electric locomotive oscillations to determine its dynamic performance. The software complex for processing the data of experimental studies of dynamic parameters of electric locomotive and comparing the results of the theoretical calculations with the data of full

  10. Consistency between Self-Reported and Recorded Values for Clinical Measures

    OpenAIRE

    III, Joseph Thomas; Paulet, Mindy; Rajpura, Jigar R.

    2016-01-01

    Objectives. This study evaluated consistency between self-reported values for clinical measures and recorded clinical measures. Methods. Self-reported values were collected for the clinical measures: systolic blood pressure, diastolic blood pressure, glucose level, height, weight, and cholesterol from health risk assessments completed by enrollees in a privately insured cohort. Body mass index (BMI) was computed from reported height and weight. Practitioner recorded values for the clinical me...

  11. Kinetics parameter measurements on RSG-GAS, a low-enriched fuel reactor

    International Nuclear Information System (INIS)

    Jujuratisbela, U; Arbie, B; Pinem, S.; Tukiran; Suparlina, L.; Singh, O.P.

    1995-01-01

    Kinetics parameter measurements, such as reactivity worths of control rods and fuel elements, beam tube void reactivity, power reactivity coefficient and xenon poisoning reactivity have been performed on different cores of Reaktor Serba Guna G.A. Siwabessy (RSG-GAS). In parallel, a programme was also initiated to measure the other kinetics parameters like effective delayed neutron life time, prompt neutron decay constant, validation of period reactivity relationship and zero power frequency response function. The paper provides the results of these measurements. (author)

  12. A measurement of the Z boson resonance parameters at the SLC [Stanford Linear Center

    International Nuclear Information System (INIS)

    Nash, J.

    1989-11-01

    We have measured the resonance parameters of the Z boson using 480 hadronic and Leptonic Z decays collected by the Mark II Detector at the Stanford Linear Collider. We find the Mass to be 91.14 ± 0.12 GeV/c 2 , and the width to be 2.42 +0.45 -0.35 GeV. If we constrain the visible width to its Standard Model value, we find a partial width to invisible decay modes corresponding to 2.8 ± 0.6 neutrino species with a 95% confidence level limit of 3.9. 9 refs., 1 fig., 4 tabs

  13. Hydrological model parameter dimensionality is a weak measure of prediction uncertainty (discussion paper)

    NARCIS (Netherlands)

    Pande, S.; Arkesteijn, L.; Savenije, H.H.G.; Bastidas, L.A.

    2014-01-01

    This paper presents evidence that model prediction uncertainty does not necessarily rise with parameter dimensionality (the number of parameters). Here by prediction we mean future simulation of a variable of interest conditioned on certain future values of input variables. We utilize a relationship

  14. IMPACT STUDY OF ANISOTROPIC OPTICAL FIBERS WINDING WITH DIFFERENT TENSION VALUE ON THE H-PARAMETER INVARIANCE DEGREE

    Directory of Open Access Journals (Sweden)

    A. B. Mukhtubayev

    2015-09-01

    Full Text Available Subject of Research. We have investigated the effect of anisotropic optical fibers winding with an elliptical sheath subjecting to stress on the H-parameter invariance degree. This type of optical fiber is used in the manufacture of fiber loop in fiber-optic gyroscopes. Method of Research. The method of research is based on the application of Michelson polarization scanning interferometer as a measuring device. Superluminescent diode with a central wavelength of 1575 nm and a half-width of the spectrum equal to 45 nm is used as a radiation source. The studies were carried out with anisotropic optical fiber with 50 m long elliptical sheath subjecting to stress. The fiber was wound with one layer turn to turn on the coil with a diameter of 18 cm, which is used in the design of fiber-optic gyroscope. The tension force of the optical fiber was controlled during winding on a special machine. Main Results. It was found that at the increase of tension force from 0.05 N to 0.8 H the value of H-parameter increases from 7×10-6 1/m up to 178×10-6 1/m, respectively; i.e. the coupling coefficient of orthogonal modes in the test fiber is being increased. Thus, it is necessary to consider the longitudinal tension force of fiber in the design and manufacture of the fiber-optic sensors of high accuracy class: the less the fiber winding power, the higher invariance degree of distributed H-parameter. The longitudinal tension force of anisotropic optical fiber with elliptical sheath subjecting to stress equal to 0.2 N is recommended in the process of designing fiber-optic gyroscopes. Practical Relevance. The proposed method of Michelson scanning interferometer is usable in the production process for quality determination of the optical fiber winding: no local defects, value controlling of fiber H-parameter.

  15. Measurement of Microwave Parameters of a Superconducting Niobium Cavity

    Science.gov (United States)

    Azaryan, N. S.; Baturitskii, M. A.; Budagov, Yu. A.; Demin, D. L.; Dem‧yanov, S. E.; Karpovich, V. A.; Kniga, V. V.; Krivosheev, R. M.; Lyubetskii, N. V.; Maksimov, S. I.; Pobol‧, I. L.; Rodionova, V. N.; Shirkov, G. D.; Shumeiko, N. M.; Yurevich, S. V.

    2017-01-01

    This paper describes a method for direct measurement of the amplitude-frequency characteristics and the Q factor of empty superconducting niobium radio frequency Tesla-type cavities. An automated measuring complex that permits recording the superconductivity effect and measuring high Q values has been developed. Measurements have been made of the Q factors of the investigated objects (the first domestic 1.3-GHz niobium cavities) at a level no lower than 0.1·109 (with a maximum value of 1.2·1010) and a level of relative losses lower than 130 dB (with a minimum factor of 139.7 dB) at liquid nitrogen temperature.

  16. Measuring opto-thermal parameters of basalt fibers using digital holographic microscopy.

    Science.gov (United States)

    Yassien, Khaled M; Agour, Mostafa

    2017-02-01

    A method for studying the effect of temperature on the optical properties of basalt fiber is presented. It is based on recording a set of phase-shifted digital holograms for the sample under the test. The holograms are obtained utilizing a system based on Mach-Zehnder interferometer, where the fiber sample inserted in an immersion liquid is placed within a temperature controlled chamber. From the recorded digital holograms the optical path differences which are used to calculate the refractive indices are determined. The accuracy in the measurement of refractive indices is in the range of 4 × 10 -4 . The influence of temperature on the dispersion parameters, polarizability per unit volume and dielectric susceptibility are also obtained. Moreover, the values of dispersion and oscillation energies and Cauchy's constants are provided at different temperatures. © 2016 Wiley Periodicals, Inc.

  17. Bayesian Parameter Estimation for Heavy-Duty Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Eric; Konan, Arnaud; Duran, Adam

    2017-03-28

    Accurate vehicle parameters are valuable for design, modeling, and reporting. Estimating vehicle parameters can be a very time-consuming process requiring tightly-controlled experimentation. This work describes a method to estimate vehicle parameters such as mass, coefficient of drag/frontal area, and rolling resistance using data logged during standard vehicle operation. The method uses Monte Carlo to generate parameter sets which is fed to a variant of the road load equation. Modeled road load is then compared to measured load to evaluate the probability of the parameter set. Acceptance of a proposed parameter set is determined using the probability ratio to the current state, so that the chain history will give a distribution of parameter sets. Compared to a single value, a distribution of possible values provides information on the quality of estimates and the range of possible parameter values. The method is demonstrated by estimating dynamometer parameters. Results confirm the method's ability to estimate reasonable parameter sets, and indicates an opportunity to increase the certainty of estimates through careful selection or generation of the test drive cycle.

  18. The Estimation of Compaction Parameter Values Based on Soil Properties Values Stabilized with Portland Cement

    Science.gov (United States)

    Lubis, A. S.; Muis, Z. A.; Pasaribu, M. I.

    2017-03-01

    The strength and durability of pavement construction is highly dependent on the properties and subgrade bearing capacity. This then led to the idea of the selection methods to estimate the density of the soil with the proper implementation of the system, fast and economical. This study aims to estimate the compaction parameter value namely the maximum dry unit weight (γd max) and optimum moisture content (wopt) of the soil properties value that stabilized with Portland Cement. Tests conducted in the laboratory of soil mechanics to determine the index properties (fines and liquid limit) and Standard Compaction Test. Soil samples that have Plasticity Index (PI) between 0-15% then mixed with Portland Cement (PC) with variations of 2%, 4%, 6%, 8% and 10%, each 10 samples. The results showed that the maximum dry unit weight (γd max) and wopt has a significant relationship with percent fines, liquid limit and the percentation of cement. Equation for the estimated maximum dry unit weight (γd max) = 1.782 - 0.011*LL + 0,000*F + 0.006*PS with R2 = 0.915 and the estimated optimum moisture content (wopt) = 3.441 + 0.594*LL + 0,025*F + 0,024*PS with R2 = 0.726.

  19. Weak measurements and quantum weak values for NOON states

    Science.gov (United States)

    Rosales-Zárate, L.; Opanchuk, B.; Reid, M. D.

    2018-03-01

    Quantum weak values arise when the mean outcome of a weak measurement made on certain preselected and postselected quantum systems goes beyond the eigenvalue range for a quantum observable. Here, we propose how to determine quantum weak values for superpositions of states with a macroscopically or mesoscopically distinct mode number, that might be realized as two-mode Bose-Einstein condensate or photonic NOON states. Specifically, we give a model for a weak measurement of the Schwinger spin of a two-mode NOON state, for arbitrary N . The weak measurement arises from a nondestructive measurement of the two-mode occupation number difference, which for atomic NOON states might be realized via phase contrast imaging and the ac Stark effect using an optical meter prepared in a coherent state. The meter-system coupling results in an entangled cat-state. By subsequently evolving the system under the action of a nonlinear Josephson Hamiltonian, we show how postselection leads to quantum weak values, for arbitrary N . Since the weak measurement can be shown to be minimally invasive, the weak values provide a useful strategy for a Leggett-Garg test of N -scopic realism.

  20. Measurement Invariance of Expectancy-Value Questionnaire in Physical Education

    Science.gov (United States)

    Zhu, Xihe; Sun, Haichun; Chen, Ang; Ennis, Catherine

    2012-01-01

    Expectancy-Value Questionnaire (EVQ) measures student expectancy beliefs and task values of the domain content (Eccles & Wigfield, 1995). In this study the authors examine measurement invariance of EVQ in the domain of physical education between elementary and middle-school students. Participants included 811 students (3rd-5th grades) from 13…

  1. Cultural Values Predicting Acculturation Orientations: Operationalizing a Quantitative Measure

    Science.gov (United States)

    Ehala, Martin

    2012-01-01

    This article proposes that acculturation orientations are related to two sets of cultural values: utilitarianism (Ut) and traditionalism (Tr). While utilitarian values enhance assimilation, traditional values support language and identity maintenance. It is proposed that the propensity to either end of this value opposition can be measured by an…

  2. Apparent diffusion coefficient measurement in glioma: Influence of region-of-interest determination methods on apparent diffusion coefficient values, interobserver variability, time efficiency, and diagnostic ability.

    Science.gov (United States)

    Han, Xu; Suo, Shiteng; Sun, Yawen; Zu, Jinyan; Qu, Jianxun; Zhou, Yan; Chen, Zengai; Xu, Jianrong

    2017-03-01

    To compare four methods of region-of-interest (ROI) placement for apparent diffusion coefficient (ADC) measurements in distinguishing low-grade gliomas (LGGs) from high-grade gliomas (HGGs). Two independent readers measured ADC parameters using four ROI methods (single-slice [single-round, five-round and freehand] and whole-volume) on 43 patients (20 LGGs, 23 HGGs) who had undergone 3.0 Tesla diffusion-weighted imaging and time required for each method of ADC measurements was recorded. Intraclass correlation coefficients (ICCs) were used to assess interobserver variability of ADC measurements. Mean and minimum ADC values and time required were compared using paired Student's t-tests. All ADC parameters (mean/minimum ADC values of three single-slice methods, mean/minimum/standard deviation/skewness/kurtosis/the10 th and 25 th percentiles/median/maximum of whole-volume method) were correlated with tumor grade (low versus high) by unpaired Student's t-tests. Discriminative ability was determined by receiver operating characteristic curves. All ADC measurements except minimum, skewness, and kurtosis of whole-volume ROI differed significantly between LGGs and HGGs (all P determination methods. Whole-volume histogram analysis did not yield better results than single-slice methods and took longer. Mean ADC value derived from single-round ROI is the most optimal parameter for differentiating LGGs from HGGs. 3 J. Magn. Reson. Imaging 2017;45:722-730. © 2016 International Society for Magnetic Resonance in Medicine.

  3. Photoelectrical measurements of the local value of the contact potential difference in the metal-insulator semiconductor (MIS) structures

    Energy Technology Data Exchange (ETDEWEB)

    Kudla, A.; Przewlocki, H.M.; Borowicz, L.; Brzezinska, D.; Rzodkiewicz, W

    2004-02-22

    In this work the local values of contact potential difference (CPD) and their distributions in the plane of the metal-insulator-semiconductor (MIS) structure's gate have been determined for the first time. This has been achieved by application of a focused beam of UV radiation from a laser source. The less than 20-{mu}m diameter of UV radiation beam allows determination of distributions of local CPD values in the plane of the gate. The CPD distribution is such that its values are highest far away from the gate edge regions, lower in the vicinity of gate edges and still lower in the vicinity of gate corners. In this paper the method and the optical setup used to determine local values of CPD are described and example measurement results are given. The CPD distributions obtained have been confirmed by a series of independent measurements by other methods. It is believed that the CPD distributions obtained (as well as distributions of local values of other parameters) are due to the mechanical stress distributions under the gate of a MIS system.

  4. An analysis of sensitivity of CLIMEX parameters in mapping species potential distribution and the broad-scale changes observed with minor variations in parameters values: an investigation using open-field Solanum lycopersicum and Neoleucinodes elegantalis as an example

    Science.gov (United States)

    da Silva, Ricardo Siqueira; Kumar, Lalit; Shabani, Farzin; Picanço, Marcelo Coutinho

    2018-04-01

    A sensitivity analysis can categorize levels of parameter influence on a model's output. Identifying parameters having the most influence facilitates establishing the best values for parameters of models, providing useful implications in species modelling of crops and associated insect pests. The aim of this study was to quantify the response of species models through a CLIMEX sensitivity analysis. Using open-field Solanum lycopersicum and Neoleucinodes elegantalis distribution records, and 17 fitting parameters, including growth and stress parameters, comparisons were made in model performance by altering one parameter value at a time, in comparison to the best-fit parameter values. Parameters that were found to have a greater effect on the model results are termed "sensitive". Through the use of two species, we show that even when the Ecoclimatic Index has a major change through upward or downward parameter value alterations, the effect on the species is dependent on the selection of suitability categories and regions of modelling. Two parameters were shown to have the greatest sensitivity, dependent on the suitability categories of each species in the study. Results enhance user understanding of which climatic factors had a greater impact on both species distributions in our model, in terms of suitability categories and areas, when parameter values were perturbed by higher or lower values, compared to the best-fit parameter values. Thus, the sensitivity analyses have the potential to provide additional information for end users, in terms of improving management, by identifying the climatic variables that are most sensitive.

  5. Interobserver and Intraobserver Variability among Measurements of FDG PET/CT Parameters in Pulmonary Tumors

    Directory of Open Access Journals (Sweden)

    Gülgün Büyükdereli

    2016-06-01

    Full Text Available Background: 18F-fluorodeoxyglucose (FDG positron emission tomography computed tomography (PET/CT provides information about metabolic and morphologic status of malignancies. Tumor size and standardized uptake value (SUV measurements are crucial for cancer treatment monitoring.: 18F-fluorodeoxyglucose (FDG positron emission tomography computed tomography (PET/CT provides information about metabolic and morphologic status of malignancies. Tumor size and standardized uptake value (SUV measurements are crucial for cancer treatment monitoring. Aims: The purpose of our study was to assess the variability of these measurements performed by observers evaluating lung tumors. Study Design: Retrospective cross-sectional study. Methods: FDG PET/CT images of 97 patients with pulmonary tumors were independently evaluated by two experienced nuclear medicine physicians. Primary tumor size (UDCT, maximum SUV (SUVmax, mean SUV (SUVmean and maximum SUV normalized to liver mean SUV (SUVnliv max were measured by each observer at two different times with an interval of at least 2 weeks. Interobserver and intraobserver variabilities of measurements were evaluated through statistical methods. Results: Size of the lesions varied from 0.81 to 13.6 cm (mean 4.29±2.24 cm. Very good agreement was shown with correlation, Bland-Altman and regression analysis for all measured PET/CT parameters. In the interobserver and intraobserver variability analysis, the Pearson correlation coefficients were greater than 0.96 and 0.98, respectively. Conclusion: Semi-quantitative measurements of pulmonary tumors were highly reproducible when determined by experienced physicians with clinically available software for routine FDG PET/CT evaluation. Consistency may be improved if the same observer performs serial measurements for any one patient.

  6. Measured radioecological parameters after the Chernobyl accident

    International Nuclear Information System (INIS)

    Bonka, H.

    1989-01-01

    After the Chernobyl accident the radioactivity in the environment in Aachen was measured in detail. The change of the different radionuclies in the eco-system made it possible to obtain radioecological parameters especially for iodine and caesium. The most important data obtained like deposition velocity, washout coefficient, retention factor, removal rate constant, and transfer factor food-milk, food-beef, and soil-grass are reported. (orig.)

  7. Blood coagulation parameters and platelet indices: changes in normal and preeclamptic pregnancies and predictive values for preeclampsia.

    Directory of Open Access Journals (Sweden)

    Lei Han

    Full Text Available Preeclampsia (PE is an obstetric disorder with high morbidity and mortality rates but without clear pathogeny. The dysfunction of the blood coagulation-fibrinolysis system is a salient characteristic of PE that varies in severity, and necessitates different treatments. Therefore, it is necessary to find suitable predictors for the onset and severity of PE.We aimed to evaluate blood coagulation parameters and platelet indices as potential predictors for the onset and severity of PE.Blood samples from 3 groups of subjects, normal pregnant women (n = 79, mild preeclampsia (mPE (n = 53 and severe preeclampsia (sPE (n = 42, were collected during early and late pregnancy. The levels of coagulative parameters and platelet indices were measured and compared among the groups. The receiver-operating characteristic (ROC curves of these indices were generated, and the area under the curve (AUC was calculated. The predictive values of the selected potential parameters were examined in binary regression analysis.During late pregnancy in the normal pregnancy group, the activated partial thromboplastin time (APTT, prothrombin time (PT, thrombin time (TT and platelet count decreased, while the fibrinogen level and mean platelet volume (MPV increased compared to early pregnancy (p<0.05. However, the PE patients presented with increased APTT, TT, MPV and D-dimer (DD during the third trimester. In the analysis of subjects with and without PE, TT showed the largest AUC (0.743 and high predictive value. In PE patients with different severities, MPV showed the largest AUC (0.671 and ideal predictive efficiency.Normal pregnancy causes a maternal physiological hypercoagulable state in late pregnancy. PE may trigger complex disorders in the endogenous coagulative pathways and consume platelets and FIB, subsequently activating thrombopoiesis and fibrinolysis. Thrombin time and MPV may serve as early monitoring markers for the onset and severity of PE

  8. Water saturation in shaly sands: logging parameters from log-derived values

    International Nuclear Information System (INIS)

    Miyairi, M.; Itoh, T.; Okabe, F.

    1976-01-01

    The methods are presented for determining the relation of porosity to formation factor and that of true resistivity of formation to water saturation, which were investigated through the log interpretation of one of the oil and gas fields of northern Japan Sea. The values of the coefficients ''a'' and ''m'' in porosity-formation factor relation are derived from cross-plot of porosity and resistivity of formation corrected by clay content. The saturation exponent ''n'' is determined from cross-plot of porosity and resistivity index on the assumption that the product of porosity and irreducible water saturation is constant. The relation of porosity to irreducible water saturation is also investigated from core analysis. The new logging parameters determined from the methods, a = 1, m = 2, n = 1.4, improved the values of water saturation by 6 percent in average, and made it easy to distinguish the points which belong to the productive zone and ones belonging to the nonproductive zone

  9. Numerical solution of system of boundary value problems using B-spline with free parameter

    Science.gov (United States)

    Gupta, Yogesh

    2017-01-01

    This paper deals with method of B-spline solution for a system of boundary value problems. The differential equations are useful in various fields of science and engineering. Some interesting real life problems involve more than one unknown function. These result in system of simultaneous differential equations. Such systems have been applied to many problems in mathematics, physics, engineering etc. In present paper, B-spline and B-spline with free parameter methods for the solution of a linear system of second-order boundary value problems are presented. The methods utilize the values of cubic B-spline and its derivatives at nodal points together with the equations of the given system and boundary conditions, ensuing into the linear matrix equation.

  10. Development of Single Optical Sensor Method for the Measurement Droplet Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Ho; Ahn, Tae Hwan; Yun, Byong Jo [Pusan National University, Busan (Korea, Republic of); Bae, Byoung Uhn; Kim, Kyoung Doo [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this study, we tried to develop single optical fiber probe(S-TOP) sensor method to measure droplet parameters such as diameter, droplet fraction, and droplet velocity and so on. To calibrate and confirm the optical fiber sensor for those parameters, we conducted visualization experiments by using a high speed camera with the optical sensor. To evaluate the performance of the S-TOP accurately, we repeated calibration experiments at a given droplet flow condition. Figure. 3 shows the result of the calibration. In this graph, the x axis is the droplet velocity measured by visualization and the y axis is grd, D which is obtained from S-TOP. In this study, we have developed the single tip optical probe sensor to measure the droplet parameters. From the calibration experiments with high speed camera, we get the calibration curve for the droplet velocity. Additionally, the chord length distribution of droplets is measured by the optical probe.

  11. Development of Single Optical Sensor Method for the Measurement Droplet Parameters

    International Nuclear Information System (INIS)

    Kim, Tae Ho; Ahn, Tae Hwan; Yun, Byong Jo; Bae, Byoung Uhn; Kim, Kyoung Doo

    2016-01-01

    In this study, we tried to develop single optical fiber probe(S-TOP) sensor method to measure droplet parameters such as diameter, droplet fraction, and droplet velocity and so on. To calibrate and confirm the optical fiber sensor for those parameters, we conducted visualization experiments by using a high speed camera with the optical sensor. To evaluate the performance of the S-TOP accurately, we repeated calibration experiments at a given droplet flow condition. Figure. 3 shows the result of the calibration. In this graph, the x axis is the droplet velocity measured by visualization and the y axis is grd, D which is obtained from S-TOP. In this study, we have developed the single tip optical probe sensor to measure the droplet parameters. From the calibration experiments with high speed camera, we get the calibration curve for the droplet velocity. Additionally, the chord length distribution of droplets is measured by the optical probe.

  12. Analysis of the value recommended by the NCRP 151 and its relationship with Brazilian parameters;Analise dos valores recomendados pelo NCRP 151 e sua relacao com parametros brasileiros

    Energy Technology Data Exchange (ETDEWEB)

    Groppo, Daniela P. [UNESP, Botucatu, SP (Brazil). Inst. de Biociencias; Martins, Homero L. [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Servico de Fisica Medica

    2009-07-01

    The methodology proposed by the National Council on Radiation Protection 151 (NCRP 151), relates technical information necessary to structural shielding design and evaluation for megavoltage X- and gamma- ray radiotherapy facilities. However, many parameters used to calculate the shield are based on estimates, and may not be adequate to the Brazilian reality. Thus, the central idea of this study is to obtain parameters and is to outline a profile closer to the treatments carried out in facilities in Brazil, through a data collection routine of the Department of Radiotherapy Service of the Real e Benemerita Associacao Portuguesa de Beneficencia, in particular the cobalt therapy Theratron 780 (Atomic Energy of Canada Ltd.) and the linear accelerator Varian Clinac 2100C for measurement of workload, use factor, number of patients, fields, dose and anatomic region treated. So, the work did not draw definite values of the parameters, but indicative values were obtained which showed the importance to carry out more detailed studies of the recommended values. (author)

  13. Gamma dosimetric parameters in some skeletal muscle relaxants

    Science.gov (United States)

    Manjunatha, H. C.

    2017-09-01

    We have studied the attenuation of gamma radiation of energy ranging from 84 keV to 1330 keV (^{170}Tm, ^{22}Na,^{137}Cs, and ^{60}Co) in some commonly used skeletal muscle relaxants such as tubocurarine chloride, gallamine triethiodide, pancuronium bromide, suxamethonium bromide and mephenesin. The mass attenuation coefficient is measured from the attenuation experiment. In the present work, we have also proposed the direct relation between mass attenuation coefficient (μ /ρ ) and mass energy absorption coefficient (μ _{en}/ρ ) based on the nonlinear fitting procedure. The gamma dosimetric parameters such as mass energy absorption coefficient (μ _{en}/ρ ), effective atomic number (Z_{eff}), effective electron density (N_{el}), specific γ-ray constant, air kerma strength and dose rate are evaluated from the measured mass attentuation coefficient. These measured gamma dosimetric parameters are compared with the theoretical values. The measured values agree with the theoretical values. The studied gamma dosimetric values for the relaxants are useful in medical physics and radiation medicine.

  14. Nonlinear parameter (B/A) measurements in methanol, 1-butanol and 1-octanol for different pressures and temperatures

    International Nuclear Information System (INIS)

    Plantier, F.; Daridon, J.L.; Lagourette, B.

    2002-01-01

    Experimental determinations versus pressure of the nonlinear acoustic parameter B/A have been conducted for methanol, 1-butanol and 1-octanol in the pressure range 0-50 MPa and temperature range 303.15-373.15 K. These measurements proceed from an experimental technique based on a phase comparison method allowing to measure the change in sound speed with the pressure for an isentropic process. The value of B/A is found to decrease with increasing pressure and seems to be an increasing function of temperature. A comparison with the data determined numerically by the classical thermodynamic method has also been performed. (author)

  15. Sexual dimorphism in visceral adiposity measures, parameters and ...

    African Journals Online (AJOL)

    Visceral adipose tissue is considered the most important anatomic site of adipose tissue aggregation and is considered the hall mark of metabolic syndrome (MetS) phenotype. The aim of the study was to determine sexual dimorphism in visceral adiposity measures, parameters and biomarkers of metabolic syndrome ...

  16. [Implicit value judgments in the measurement of health inequalities].

    Science.gov (United States)

    Harper, Sam; King, Nicholas B; Meersman, Stephen C; E Reichman, Marsha; Breen, Nancy; Lynch, John

    2014-04-01

    Quantitative estimates of the magnitude, direction, and rate of change of health inequalities play a crucial role in creating and assessing policies aimed at eliminating the disproportionate burden of disease in disadvantaged populations. It is generally assumed that the measurement of health inequalities is a value-neutral process, providing objective data that are then interpreted using normative judgments about whether a particular distribution of health is just, fair, or socially acceptable. We discuss five examples in which normative judgments play a role in the measurement process itself, through either the selection of one measurement strategy to the exclusion of others or the selection of the type, significance, or weight assigned to the variables being measured. Overall, we find that many commonly used measures of inequality are value laden and that the normative judgments implicit in these measures have important consequences for interpreting and responding to health inequalities. Because values implicit in the generation of health inequality measures may lead to radically different interpretations of the same underlying data,we urge researchers to explicitly consider and transparently discuss the normative judgments underlying their measures. We also urge policymakers and other consumers of health inequalities data to pay close attention to the measures on which they base their assessments of current and future health policies.

  17. Implicit value judgments in the measurement of health inequalities.

    Science.gov (United States)

    Harper, Sam; King, Nicholas B; Meersman, Stephen C; Reichman, Marsha E; Breen, Nancy; Lynch, John

    2010-03-01

    Quantitative estimates of the magnitude, direction, and rate of change of health inequalities play a crucial role in creating and assessing policies aimed at eliminating the disproportionate burden of disease in disadvantaged populations. It is generally assumed that the measurement of health inequalities is a value-neutral process, providing objective data that are then interpreted using normative judgments about whether a particular distribution of health is just, fair, or socially acceptable. We discuss five examples in which normative judgments play a role in the measurement process itself, through either the selection of one measurement strategy to the exclusion of others or the selection of the type, significance, or weight assigned to the variables being measured. Overall, we find that many commonly used measures of inequality are value laden and that the normative judgments implicit in these measures have important consequences for interpreting and responding to health inequalities. Because values implicit in the generation of health inequality measures may lead to radically different interpretations of the same underlying data, we urge researchers to explicitly consider and transparently discuss the normative judgments underlying their measures. We also urge policymakers and other consumers of health inequalities data to pay close attention to the measures on which they base their assessments of current and future health policies.

  18. Valuing Ecosystem Services with Fishery Rents: A Lumped-Parameter Approach to Hypoxia in the Neuse River Estuary

    Directory of Open Access Journals (Sweden)

    Larry B. Crowder

    2011-11-01

    Full Text Available Valuing ecosystem services with microeconomic underpinnings presents challenges because these services typically constitute nonmarket values and contribute to human welfare indirectly through a series of ecological pathways that are dynamic, nonlinear, and difficult to quantify and link to appropriate economic spatial and temporal scales. This paper develops and demonstrates a method to value a portion of ecosystem services when a commercial fishery is dependent on the quality of estuarine habitat. Using a lumped-parameter, dynamic open access bioeconomic model that is spatially explicit and includes predator-prey interactions, this paper quantifies part of the value of improved ecosystem function in the Neuse River Estuary when nutrient pollution is reduced. Specifically, it traces the effects of nitrogen loading on the North Carolina commercial blue crab fishery by modeling the response of primary production and the subsequent impact on hypoxia (low dissolved oxygen. Hypoxia, in turn, affects blue crabs and their preferred prey. The discounted present value fishery rent increase from a 30% reduction in nitrogen loadings in the Neuse is $2.56 million, though this welfare estimate is fairly sensitive to some parameter values. Surprisingly, this number is not sensitive to initial conditions.

  19. Adam Smith's Concept of Labour: Value or Measure?

    OpenAIRE

    Adolfo Rodriguez-Herrera

    2014-01-01

    The terminology employed by Smith to refer to value and measure of value is used in his time with imprecision, which has led to different interpretations about his position on these issues. It is no coincidence that Smith is considered the father of the labour theory of value developed by David Ricardo and Karl Marx and simultaneously of the cost-of-production theory of value developed by John Stuart Mill and Alfred Marshall. This paper reviews the concepts developed by Smith to formulate his...

  20. Dyes assay for measuring physicochemical parameters.

    Science.gov (United States)

    Moczko, Ewa; Meglinski, Igor V; Bessant, Conrad; Piletsky, Sergey A

    2009-03-15

    A combination of selective fluorescent dyes has been developed for simultaneous quantitative measurements of several physicochemical parameters. The operating principle of the assay is similar to electronic nose and tongue systems, which combine nonspecific or semispecific elements for the determination of diverse analytes and chemometric techniques for multivariate data analysis. The analytical capability of the proposed mixture is engendered by changes in fluorescence signal in response to changes in environment such as pH, temperature, ionic strength, and presence of oxygen. The signal is detected by a three-dimensional spectrofluorimeter, and the acquired data are processed using an artificial neural network (ANN) for multivariate calibration. The fluorescence spectrum of a solution of selected dyes allows discreet reading of emission maxima of all dyes composing the mixture. The variations in peaks intensities caused by environmental changes provide distinctive fluorescence patterns which can be handled in the same way as the signals collected from nose/tongue electrochemical or piezoelectric devices. This optical system opens possibilities for rapid, inexpensive, real-time detection of a multitude of physicochemical parameters and analytes of complex samples.

  1. The physical interpretation of the parameters measured during the tensile testing of materials at elevated temperatures

    International Nuclear Information System (INIS)

    Burton, B.

    1984-01-01

    Hot tensile (or compression) testing, where the stress developed in a material is measured under an imposed strain rate, is often used as an alternative to conventional creep testing. The advantages of the hot tensile test are that its duration can be more closely controlled by the experimenter and also that the technique is more convenient, since high precision testing machines are available. The main disadvantage is that the interpretation of results is more complex. The present paper relates the parameters which are measured in hot tensile tests, to physical processes which occur in materials deforming by a variety of mechanisms. For cases where no significant structural changes occur, as in viscous or superplastic flow, analytical expressions are derived which relate the stresses measured in these tests to material constants. When deformation is controlled by recovery processes, account has to be taken of the structural changes which occur concurrently. A wide variety of behaviour may then be exhibited which depends on the initial dislocation density, the presence of second-phase particles and the relative values of the recovery rate parameters and the velocity imposed by the testing machine. Numerical examples are provided for simple recovery models. (author)

  2. A method for realistic assessment of the environmental load following an accident in a nuclear facility taking into consideration measured values from environment monitoring

    International Nuclear Information System (INIS)

    Geiss, H.

    1985-01-01

    To enable consideration of time and space variations of source properties and of meteorological parameters, the quasi-stationary computational programme MUSEMET was developed for risk assessment. It was the modified for use in the prognosis of radiation exposure following accidents, in view of on-line registration of current meteorological data in 5- or 10-minute increments. By direct time-dependent continuous measurement of turbulence parameters a classification of diffusion categories is no more required. The diffusion parameters needed for this quasi-instationary Gaussian model are also determined continuously from turbulence measurements. MUSEMET and/or the follow-up programme MUSEDOS allow the determination of time- and location-dependent individual dose rates received by inhalation, γ- and β-submersion, γ-radiation from contaminated floors and by ingestion. An illustration is made in time-dependent form on a graphic display showing isodose lines together with a map of the site surroundings, or in tables. The anticipated values are continuously compared with the measured values from environment monitoring. γ-spectrometric measurements in particular can be exploited for calculations designed to enable accurate statements on the source, and the prognosis can be corrected accordingly. (orig./HP) [de

  3. Measurements of local two-phase flow parameters in a boiling flow channel

    International Nuclear Information System (INIS)

    Yun, Byong Jo; Park, Goon-CherI; Chung, Moon Ki; Song, Chul Hwa

    1998-01-01

    Local two-phase flow parameters were measured lo investigate the internal flow structures of steam-water boiling flow in an annulus channel. Two kinds of measuring methods for local two-phase flow parameters were investigated. These are a two-conductivity probe for local vapor parameters and a Pitot cube for local liquid parameters. Using these probes, the local distribution of phasic velocities, interfacial area concentration (IAC) and void fraction is measured. In this study, the maximum local void fraction in subcooled boiling condition is observed around the heating rod and the local void fraction is smoothly decreased from the surface of a heating rod to the channel center without any wall void peaking, which was observed in air-water experiments. The distributions of local IAC and bubble frequency coincide with those of local void fraction for a given area-averaged void fraction. (author)

  4. Measure-valued solutions to the complete Euler system revisited

    Science.gov (United States)

    Březina, Jan; Feireisl, Eduard

    2018-06-01

    We consider the complete Euler system describing the time evolution of a general inviscid compressible fluid. We introduce a new concept of measure-valued solution based on the total energy balance and entropy inequality for the physical entropy without any renormalization. This class of so-called dissipative measure-valued solutions is large enough to include the vanishing dissipation limits of the Navier-Stokes-Fourier system. Our main result states that any sequence of weak solutions to the Navier-Stokes-Fourier system with vanishing viscosity and heat conductivity coefficients generates a dissipative measure-valued solution of the Euler system under some physically grounded constitutive relations. Finally, we discuss the same asymptotic limit for the bi-velocity fluid model introduced by H.Brenner.

  5. Assessment on Evaluating Parameters of Rice Core Collections Constructed by Genotypic Values and Molecular Marker Information

    Directory of Open Access Journals (Sweden)

    Jian-cheng WANG

    2007-06-01

    Full Text Available Eleven evaluating parameters for rice core collection were assessed based on genotypic values and molecular marker information. Monte Carlo simulation combined with mixed linear model was used to eliminate the interference from environment in order to draw more reliable results. The coincidence rate of range (CR was the optimal parameter. Mean Simpson index (MD, mean Shannon-Weaver index of genetic diversity (MI and mean polymorphism information content (MPIC were important evaluating parameters. The variable rate of coefficient of variation (VR could act as an important reference parameter for evaluating the variation degree of core collection. Percentage of polymorphic loci (p could be used as a determination parameter for the size of core collection. Mean difference percentage (MD was a determination parameter for the reliability judgment of core collection. The effective evaluating parameters for core collection selected in the research could be used as criteria for sampling percentage in different plant germplasm populations.

  6. Fast determination of plasma parameters

    International Nuclear Information System (INIS)

    Wijnands, T.J.; Parlange, F.; Joffrin, E.

    1995-01-01

    Fast analysis of diagnostic signals of a tokamak discharge is demonstrated by using 4 fundamentally different techniques. A comparison between Function Parametrization (FP), Canonical Correlation Analysis (CCA) and a particular Neural Network (NN) configuration known as the Multi Layer Perceptron (MLP) is carried out, thereby taking a unique linear model based on a Singular Value Decomposition (SVD) as a reference. The various techniques provide all functional representations of characteristic plasma parameters in terms of the values of the measurements and are based on an analysis of a large, experimentally achieved database. A brief mathematical description of the various techniques is given, followed by two particular applications to Tore Supra diagnostic data. The first problem is concerned with the identification of the plasma boundary parameters using the poloidal field and differential poloidal flux measurements. A second application involves the interpretation of line integrated data from the multichannel interfero-polarimeter to obtain the central value of the safety factor. (author) 4 refs.; 3 figs

  7. Different methods of measuring ADC values in normal human brain

    International Nuclear Information System (INIS)

    Wei Youping; Sheng Junkang; Zhang Caiyuan

    2009-01-01

    Objective: To investigate better method of measuring ADC values of normal brain, and provide reference for further research. Methods: Twenty healthy people's MR imaging were reviewed. All of them underwent routine MRI scans and echo-planar diffusion-weighted imaging (DWI), and ADC maps were reconstructed on work station. Six regions of interest (ROI) were selected for each object, the mean ADC values were obtained for each position on DWI and ADC maps respectively. Results: On the anisotropic DWI map calculated in the hypothalamus, ADC M , ADC P , ADC S values were no significant difference (P>0.05), in the frontal white matter and internal capsule hindlimb, there was a significant difference (P ave value exist significant difference to direct measurement on the anisotropic (isotropic) ADC map (P<0.001). Conclusion: Diffusion of water in the frontal white matter and internal capsule are anisotropic, but it is isotropic in the hypothalamus; different quantitative methods of diffusion measurement of 4ADC values have significant difference, but ADC values calculated through the DWI map is more accurate, quantitative diffusion study of brain tissue should also consider the diffusion measurement method. (authors)

  8. Multi-Parameter Measurement in Unseeded Flows using Femtosecond Lasers

    Data.gov (United States)

    National Aeronautics and Space Administration — Our approach is to use new turn-key femtosecond laser technology along with new high-speed CMOS camera technology to build a multi-parameter measurement system based...

  9. Comparison of the values of measured hydratation of sporting youths with normative values

    Directory of Open Access Journals (Sweden)

    Petr Kutáč

    2013-06-01

    Full Text Available BACKROUND: When measuring body composition, we monitor the fractionalization of body weight and the share of the individual elements in its aggregate value. The total body water (TBW is a very important element in addition to the share of body fat (BF, muscle mass and bone minerals. Water is the largest element of the body weight and its sufficient amount (organism hydration is a condition for maintaining the physiological functions of the person and thus has an immediate effect on the health of the individual. OBJECTIVE: The aim of the study is to check the standard values of the percentage share of the representation of the total body water in the total body weight in different age groups of sporting youths using the tetrapolar bio-impedance Tanita 418 MA scale. METHODS: The research group included a total of 532 individuals (332 men and 200 women at the age from 12 to 17 years. They were individuals with regular physical activity and without any health problems. The measurement was carried out using the tetrapolar bio-impedance TANITA 418 MA scale. The confidence interval at the reliability level of .99 was used to define the range of the standard values of the percentage share of the total body water representation. The normalization index Ni was used to compare the mean values of the total body water representation with the reference file. RESULTS: The mean values of the TBW representation in boys ranged from 61.75 to 64.34% and in girls from 55.51 to 58.69%, always in relation to the age. The value of the upper bound of (95% the confidence interval of the Tanita 418 MA device software did not exceed the lower bound of the standard (65% in any of the monitored files. CONCLUSIONS: The results showed significant gender differences in the total body water representation that, however, the standard of the used device does not respect. The standard values are set high which was also confirmed by the comparison of our results with other studies

  10. A summary of the sources of input parameter values for the Waste Isolation Pilot Plant final porosity surface calculations

    International Nuclear Information System (INIS)

    Butcher, B.M.

    1997-08-01

    A summary of the input parameter values used in final predictions of closure and waste densification in the Waste Isolation Pilot Plant disposal room is presented, along with supporting references. These predictions are referred to as the final porosity surface data and will be used for WIPP performance calculations supporting the Compliance Certification Application to be submitted to the U.S. Environmental Protection Agency. The report includes tables and list all of the input parameter values, references citing their source, and in some cases references to more complete descriptions of considerations leading to the selection of values

  11. A summary of the sources of input parameter values for the Waste Isolation Pilot Plant final porosity surface calculations

    Energy Technology Data Exchange (ETDEWEB)

    Butcher, B.M.

    1997-08-01

    A summary of the input parameter values used in final predictions of closure and waste densification in the Waste Isolation Pilot Plant disposal room is presented, along with supporting references. These predictions are referred to as the final porosity surface data and will be used for WIPP performance calculations supporting the Compliance Certification Application to be submitted to the U.S. Environmental Protection Agency. The report includes tables and list all of the input parameter values, references citing their source, and in some cases references to more complete descriptions of considerations leading to the selection of values.

  12. Comparison of results from simple expressions for MOSFET parameter extraction

    Science.gov (United States)

    Buehler, M. G.; Lin, Y.-S.

    1988-01-01

    In this paper results are compared from a parameter extraction procedure applied to the linear, saturation, and subthreshold regions for enhancement-mode MOSFETs fabricated in a 3-micron CMOS process. The results indicate that the extracted parameters differ significantly depending on the extraction algorithm and the distribution of I-V data points. It was observed that KP values vary by 30 percent, VT values differ by 50 mV, and Delta L values differ by 1 micron. Thus for acceptance of wafers from foundries and for modeling purposes, the extraction method and data point distribution must be specified. In this paper measurement and extraction procedures that will allow a consistent evaluation of measured parameters are discussed.

  13. Activation method for measuring the neutron spectra parameters. Computer software

    International Nuclear Information System (INIS)

    Efimov, B.V.; Ionov, V.S.; Konyaev, S.I.; Marin, S.V.

    2005-01-01

    The description of mathematical statement of a task for definition the spectral characteristics of neutron fields with use developed in RRC KI unified activation detectors (UKD) is resulted. The method of processing of results offered by authors activation measurements and calculation of the parameters used for an estimation of the neutron spectra characteristics is discussed. Features of processing of the experimental data received at measurements of activation with using UKD are considered. Activation detectors UKD contain a little bit specially the picked up isotopes giving at irradiation peaks scale of activity in the common spectrum scale of activity. Computing processing of results of the measurements is applied on definition of spectrum parameters for nuclear reactor installations with thermal and close to such power spectrum of neutrons. The example of the data processing, the measurements received at carrying out at RRC KI research reactor F-1 is resulted [ru

  14. First Measurements of Higher Order Optics Parameters in the LHC

    CERN Document Server

    Vanbavinckhove, G; Bartolini, R; Calaga, R; Giovannozzi, M; Maclean, E H; Miyamoto, R; Schmidt, F; Tomas, R

    2011-01-01

    Higher order effects can play an important role in the performance of the LHC. Lack of knowledge of these pa- rameters can increase the tune footprint and compromise the beam lifetime. First measurements of these parameters at injection and flattop have been conducted. Detailed sim- ulations are compared to the measurements together with discussions on the measurement limitations.

  15. Measurement and estimation of dew point for SNG. [Comparison of calculated and measured values

    Energy Technology Data Exchange (ETDEWEB)

    Furuyama, Y.

    1974-08-01

    Toho Gas measured and estimated SNG dew points in high-pressure deliveries by calculating the theoretical values by the high-pressure gas-liquid equilibrium theory using the pressure-extrapolation method to reach K = 1, and the BWR method to estimate fugacity, then verifying these values experimentally. The experimental values were measured at 161.7 to 367.5 psi using the conventional static and circulation methods, in addition to a newly developed method consisting of circulating a known composition of gas mixtures, partially freezing them, and monitoring the dew point by observing the droplets on a mirror cooled by blowing liquid nitrogen. Good agreement was found between the calculated and the experimental values.

  16. Measurement of the Z Resonance Parameters at LEP

    CERN Document Server

    Barate, R; Ghez, P; Goy, C; Lees, J P; Lucotte, A; Merle, E; Minard, M N; Pietrzyk, B; Alemany, R; Casado, M P; Chmeissani, M; Comas, P; Crespo, J M; Fernández, E; Fernández-Bosman, M; Garrido, L; Graugès-Pous, E; Juste, A; Martínez, M; Merino, G; Miquel, R; Mir, L M; Orteu, S; Pacheco, A; Park, I C; Perlas, J A; Riu, I; Sánchez, F; Colaleo, A; Creanza, D; De Palma, M; Iaselli, Giuseppe; Maggi, G; Maggi, M; Nuzzo, S; Ranieri, A; Raso, G; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Tricomi, A; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Abbaneo, D; Bazarko, A; Becker, U; Boix, G; Bird, F; Blucher, E; Bonvicini, G; Bright-Thomas, P G; Cattaneo, M; Cerutti, F; Ciulli, V; Dissertori, G; Drevermann, H; Forty, Roger W; Frank, M; Greening, T C; Hagelberg, R; Halley, A W; Hansen, J B; Harvey, J; Jacobsen, R; Janot, P; Jost, B; Knobloch, J; Lazeyras, Pierre; Lehraus, Ivan; Maley, P; Mato, P; May, J; Moutoussi, A; Ranjard, F; Rolandi, Luigi; Schlatter, W D; Schmitt, M; Schneider, O; Spagnolo, P; Tejessy, W; Teubert, F; Tomalin, I R; Tournefier, E; Veenhof, R; Wiedenmann, W; Wright, A E; Ajaltouni, Ziad J; Badaud, F; Chazelle, G; Deschamps, O; Falvard, A; Ferdi, C; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Montret, J C; Pallin, D; Perret, P; Podlyski, F; Bertelsen, H; Fernley, T; Hansen, F; Hansen, J D; Hansen, J R; Hansen, P H; Lindahl, A; Møllerud, R; Nilsson, B S; Rensch, B; Wäänänen, A; Daskalakis, G; Kyriakis, A; Markou, C; Simopoulou, Errietta; Siotis, I; Vayaki, Anna; Blondel, A; Bonneaud, G R; Brient, J C; Rougé, A; Rumpf, M; Swynghedauw, M; Tanaka, R; Verderi, M; Videau, H L; Focardi, E; Parrini, G; Zachariadou, K; Cavanaugh, R J; Corden, M; Georgiopoulos, C H; Antonelli, A; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, F; Murtas, G P; Passalacqua, L; Pepé-Altarelli, M; Picchi, P; Colrain, P; ten Have, I; Hughes, I S; Knowles, I G; Lynch, J G; Morton, W T; Raine, C; Reeves, P; O'Shea, V; Scarr, J M; Smith, K; Thompson, A S; Turnbull, R M; Buchmüller, O L; Dhamotharan, S; Geweniger, C; Hanke, P; Hansper, G; Hepp, V; Kluge, E E; Putzer, A; Sommer, J; Tittel, K; Werner, S; Wunsch, M; Beuselinck, R; Binnie, David M; Cameron, W; Dornan, Peter J; Girone, M; Goodsir, S M; Martin, E B; Marinelli, N; Nash, J; Sciabà, A; Sedgbeer, J K; Thomson, E; Williams, M D; Ghete, V M; Girtler, P; Kneringer, E; Kuhn, D; Rudolph, G; Bowdery, C K; Buck, P G; Finch, A J; Foster, F; Hughes, G; Jones, R W L; Keemer, N R; Robertson, N A; Sloan, Terence; Snow, S W; Williams, M I; Bauerdick, L A T; Van Gemmeren, P; Giehl, I; Jakobs, K; Kasemann, M; Kleinknecht, K; Quast, G; Renk, B; Rohne, E; Sander, H G; Schmelling, M; Wachsmuth, H W; Wanke, R; Zeitnitz, C; Aubert, Jean-Jacques; Benchouk, C; Bonissent, A; Carr, J; Coyle, P; Etienne, F; Motsch, F; Payre, P; Rousseau, D; Talby, M; Thulasidas, M; Aleppo, M; Antonelli, M; Ragusa, F; Büscher, V; Dietl, H; Ganis, G; Hüttmann, K; Lütjens, G; Mannert, C; Männer, W; Moser, H G; Schael, S; Settles, Ronald; Seywerd, H C J; Stenzel, H; Wolf, G; Azzurri, P; Boucrot, J; Callot, O; Chen, S; Cordier, A; Davier, M; Duflot, L; Grivaz, J F; Heusse, P; Jacholkowska, A; Le Diberder, F R; Lefrançois, J; Lutz, A M; Schune, M H; Veillet, J J; Videau, I; Zerwas, D; Bagliesi, G; Bettarini, S; Boccali, T; Bozzi, C; Calderini, G; Dell'Orso, R; Fantechi, R; Ferrante, I; Fidecaro, F; Foà, L; Giassi, A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Palla, Fabrizio; Rizzo, G; Sanguinetti, G; Sguazzoni, G; Steinberger, Jack; Tenchini, Roberto; Vannini, C; Venturi, A; Verdini, P G; Blair, G A; Cowan, G D; Green, M G; Medcalf, T; Strong, J A; Von Wimmersperg-Töller, J H; Botterill, David R; Clifft, R W; Edgecock, T R; Edwards, M; Haywood, S J; Norton, P R; Thompson, J C; Bloch-Devaux, B; Colas, P; Emery, S; Kozanecki, Witold; Lançon, E; Lemaire, M C; Locci, E; Pérez, P; Rander, J; Renardy, J F; Roussarie, A; Schuller, J P; Schwindling, J; Vallage, B; Black, S N; Dann, J H; Kim, H Y; Konstantinidis, N P; Litke, A M; McNeil, M A; Taylor, G; Booth, C N; Cartwright, S L; Combley, F; Lehto, M H; Thompson, L F; Affholderbach, K; Barberio, E; Böhrer, A; Brandt, S; Burkhardt, H; Feigl, E; Grupen, Claus; Hess, J; Lutters, G; Meinhard, H; Minguet-Rodríguez, J A; Mirabito, L; Misiejuk, A; Neugebauer, E; Prange, G; Rivera, F; Saraiva, P; Schäfer, U; Sieler, U; Smolik, L; Stephan, F; Trier, H; Apollonio, M; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Musolino, G; Pitis, L; Kim, H; Rothberg, J E; Wasserbaech, S R; Armstrong, S R; Bellantoni, L; Cinabro, D; Conway, J S; Elmer, P; Feng, Z; Ferguson, D P S; Gao, Y; González, S; Grahl, J; Harton, J L; Hayes, O J; Hu, H; Jin, S; Johnson, R P; Kile, J; McNamara, P A; Nielsen, J; Orejudos, W; Pan, Y B; Saadi, Y; Scott, I J; Sharma, V; Walsh, A M; Walsh, J; Wear, J; Wu Sau Lan; Wu, X; Yamartino, J M; Zobernig, G

    2000-01-01

    The properties of the Z resonance are measured from the analysis of 4.5 million Z decays into fermion pairs collected with the \\Aleph\\ detector at L EP. The data are consistent with lepton universality. The resonance parameters are measured to be $\\MZ=(91.1885 \\pm 0.0031)~\\Gevcc$, $\\GZ= (2.4951 \\pm 0.0043)~\\GeV$, $\\spol=(41.559 \\pm 0.058)$~nb and, combining the three lepton flavours $\\Rl= 20.725\\pm 0.039$. The corresponding number of light neutrino species is $N_{\

  17. A method for valuing architecture-based business transformation and measuring the value of solutions architecture

    OpenAIRE

    Slot, R.G.

    2010-01-01

    Enterprise and Solution Architecture are key in today’s business environment. It is surprising that the foundation and business case for these activities are nonexistent; the financial value for the business of these activities is largely undetermined. To determine business value of enterprise and solution architecture, this thesis shows how to measure and quantify, in business terms, the value of enterprise architecture-based on business transformation and the value of solution architecture.

  18. Off-line tracking of series parameters in distribution systems using AMI data

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Tess L.; Sun, Yannan; Schneider, Kevin

    2016-05-01

    Electric distribution systems have historically lacked measurement points, and equipment is often operated to its failure point, resulting in customer outages. The widespread deployment of sensors at the distribution level is enabling observability. This paper presents an off-line parameter value tracking procedure that takes advantage of the increasing number of measurement devices being deployed at the distribution level to estimate changes in series impedance parameter values over time. The tracking of parameter values enables non-diurnal and non-seasonal change to be flagged for investigation. The presented method uses an unbalanced Distribution System State Estimation (DSSE) and a measurement residual-based parameter estimation procedure. Measurement residuals from multiple measurement snapshots are combined in order to increase the effective local redundancy and improve the robustness of the calculations in the presence of measurement noise. Data from devices on the primary distribution system and from customer meters, via an AMI system, form the input data set. Results of simulations on the IEEE 13-Node Test Feeder are presented to illustrate the proposed approach applied to changes in series impedance parameters. A 5% change in series resistance elements can be detected in the presence of 2% measurement error when combining less than 1 day of measurement snapshots into a single estimate.

  19. Volume variation of Gruneisen parameters of fcc transition metals

    Indian Academy of Sciences (India)

    Unknown

    average discrepancy between the values of γ measured by various methods for 23 metals. Experimentally only the total Gruneisen parameter can be measured. The total. Gruneisen parameter is the sum of lattice, electronic and probably magnetic contribution. The letter term is present in palladium (White and Pawlok 1970) ...

  20. Implications of the top quark mass measurement for the CKM parameters, x$_{s}$ and CP asymmetries

    CERN Document Server

    Ali, A; London, D

    1995-01-01

    Motivated by the recent determination of the top quark mass by the CDF collaboration, \\mt =174 \\pm 10 ^{+13}_{-12} GeV, we review and update the constraints on the parameters of the quark flavour mixing matrix V_{CKM} in the standard model. In performing our fits, we use inputs from the measurements of the following quantities: (i) \\abseps, the CP-violating parameter in K decays, (ii) \\delmd, the mass difference due to the \\bdbdbar\\ mixing, (iii) the matrix elements \\absvcb and \\absvub, and (iv) B-hadron lifetimes. We find that the allowed region of the unitarity triangle is very large, mostly due to theoretical uncertainties. (This emphasizes the importance of measurements of CP-violating rate asymmetries in the B system.) Nevertheless, the present data do somewhat restrict the allowed values of the coupling constant product f_{B_d}\\sqrt{\\hat{B}_{B_d}} and the renormalization-scale invariant bag constant \\hat{B}_K. With the updated CKM matrix we present the currently-allowed range of the ratio \\vert V_{td}/V...

  1. 113Insup(m) radiocardiographic measurements of cardiopulmonary parameters in healthy subjects and in cardiac patients

    International Nuclear Information System (INIS)

    Kuikka, Jyrki.

    1976-05-01

    Single detector arrangements are used to measure heart radioactivity curves in healthy subjects and in patients with various heart failures. A method is developed from a modified gamma function to determine the cardiopulmonary parameters from the radiocardiograms: systemic flow, pulmonary flow, right to left shunting flow, left to right shunting flow, regurgitant fractions, stroke volume, atrial blood volumes, ventricular end-diastolic volumes, pulmonary blood volume and ejection fractions. The method is well suited to clinical routine and requires only a desk calculator or a mini-computer for data handling. The cardiopulmonary parameters were measured from 70 healthy subjects with following results: cardiac index 3.46+-0.72 l/min/m 2 , stroke index 49+-9 ml/b/m 2 , right atrial blood volume 35+-13 ml/m 2 , right ventricular end-diastolic volume 76+-15 ml/m 2 , pulmonary blood volume 250+-51 ml/m 2 , left atrial blood volume 41+-15 ml/m 2 , left ventricular end-diastolic volume 75+-15 ml/m 2 , right heart ejection fraction 0.64+-0.11, left heart ejection fraction 0.66+-0.12. These values agree closely with the data accumulated from more elaborate methods. (author)

  2. The impact of reliable prebolus T 1 measurements or a fixed T 1 value in the assessment of glioma patients with dynamic contrast enhancing MRI.

    Science.gov (United States)

    Tietze, Anna; Mouridsen, Kim; Mikkelsen, Irene Klærke

    2015-06-01

    Accurate quantification of hemodynamic parameters using dynamic contrast enhanced (DCE) MRI requires a measurement of tissue T 1 prior to contrast injection (T 1). We evaluate (i) T 1 estimation using the variable flip angle (VFA) and the saturation recovery (SR) techniques and (ii) investigate if accurate estimation of DCE parameters outperform a time-saving approach with a predefined T 1 value when differentiating high- from low-grade gliomas. The accuracy and precision of T 1 measurements, acquired by VFA and SR, were investigated by computer simulations and in glioma patients using an equivalence test (p > 0.05 showing significant difference). The permeability measure, K trans, cerebral blood flow (CBF), and - volume, V p, were calculated in 42 glioma patients, using fixed T 1 of 1500 ms or an individual T 1 measurement, using SR. The areas under the receiver operating characteristic curves (AUCs) were used as measures for accuracy to differentiate tumor grade. The T 1 values obtained by VFA showed larger variation compared to those obtained using SR both in the digital phantom and the human data (p > 0.05). Although a fixed T 1 introduced a bias into the DCE calculation, this had only minor impact on the accuracy differentiating high-grade from low-grade gliomas, (AUCfix = 0.906 and AUCind = 0.884 for K trans; AUCfix = 0.863 and AUCind = 0.856 for V p; p for AUC comparison > 0.05). T 1 measurements by VFA were less precise, and the SR method is preferable, when accurate parameter estimation is required. Semiquantitative DCE values, based on predefined T 1 values, were sufficient to perform tumor grading in our study.

  3. Uncertainty estimation of core safety parameters using cross-correlations of covariance matrix

    International Nuclear Information System (INIS)

    Yamamoto, Akio; Yasue, Yoshihiro; Endo, Tomohiro; Kodama, Yasuhiro; Ohoka, Yasunori; Tatsumi, Masahiro

    2013-01-01

    An uncertainty reduction method for core safety parameters, for which measurement values are not obtained, is proposed. We empirically recognize that there exist some correlations among the prediction errors of core safety parameters, e.g., a correlation between the control rod worth and the assembly relative power at corresponding position. Correlations of errors among core safety parameters are theoretically estimated using the covariance of cross sections and sensitivity coefficients of core parameters. The estimated correlations of errors among core safety parameters are verified through the direct Monte Carlo sampling method. Once the correlation of errors among core safety parameters is known, we can estimate the uncertainty of a safety parameter for which measurement value is not obtained. (author)

  4. Reconstruction of Chernobyl source parameters using gamma dose rate measurements in town Pripjat

    Directory of Open Access Journals (Sweden)

    M. M. Talerko

    2010-06-01

    Full Text Available With the help of mathematical modeling of atmospheric transport the calculations of accidental release dispersion from the Chernobyl NPP to town Pripjat during period from 26 till 29 April 1986 have been carried out. Data of gamma rate measurements which was made in 31 points of the town were used. Based on the solution of atmospheric transport inverse problem the reconstruction of Chernobyl source parameters has been made including release intensity and effective source height. The input of main dose-forming radionuclides into the exposure dose during the first 40 hours after the accident (the period of population residence in the town before the evacuation has been estimated. According to the calculations the 131I deposition density averaged over the town territory was about 5.2 × 104 kBq/m2 (on 29.04.86. Minimum and maximum 131I deposition values were 2.8 × 104 kBq/m2 (western part, distance to the unit is 4.5 km and 1.2 × 105 kBq/m2 (north-eastern part of town, 2 km from the unit accordingly. For the moment of the evacuation dated April 27, deposition values were about 90 percent of these values.

  5. Impact of Uncertainties in the Cosmological Parameters on the Measurement of Primordial non-Gaussianity

    CERN Document Server

    Liguori, M

    2008-01-01

    We study the impact of cosmological parameters' uncertainties on estimates of the primordial NG parameter f_NL in local and equilateral models of non-Gaussianity. We show that propagating these errors increases the f_NL relative uncertainty by 16% for WMAP and 5 % for Planck in the local case, whereas for equilateral configurations the correction term are 14% and 4%, respectively. If we assume for local f_NL a central value of order 60, according to recent WMAP 5-years estimates, we obtain for Planck a final correction \\Delta f_NL = 3. Although not dramatic, this correction is at the level of the expected estimator uncertainty for Planck, and should then be taken into account when quoting the significance of an eventual future detection. In current estimates of f_NL the cosmological parameters are held fixed at their best-fit values. We finally note that the impact of uncertainties in the cosmological parameters on the final f_NL error bar would become totally negligible if the parameters were allowed to vary...

  6. Critical parameters for ammonia

    International Nuclear Information System (INIS)

    Sato, M.; Masui, G.; Uematsu, M.

    2005-01-01

    (p, ρ, T) measurements and visual observations of the meniscus for ammonia were carried out carefully in the critical region over the range of temperatures: -1 K (T - T c ) 0.04 K, and of densities: -19 kg . m -3 (ρ - ρ c ) 19 kg . m -3 by a metal-bellows volumometer with an optical cell. Vapor pressures were also measured at T = (310, 350, and 400) K. The critical parameters of T c and ρ c were determined based on the results of observation of the critical opalescence. The critical pressure p c was determined from the present measurements at T c on the vapor pressure curve. Comparisons of the critical parameters with values given in the literature are presented

  7. The measurement and calculation of the kinetic parameter {beta}{sub eff}/{Lambda} of a small high-temperature like, critical system

    Energy Technology Data Exchange (ETDEWEB)

    Wallerbos, E.J.M.; Hoogenboom, J.E. [Interfaculty Reactor Inst., Delft Univ. of Technology, Delft (Netherlands)

    1998-01-01

    This paper demonstrates that it is well possible to determine the kinetic parameter {beta}{sub eff}/{Lambda} in a neutronically very slow system by means of noise measurements in the critical state. The advantages of this technique are that it can be conducted in a critical reactor directly, and that no special measurement equipment is needed. The comparison to calculated values for four configurations, which differ in the amount of moderation in the core region, shows a satisfactory agreement. (author)

  8. Study of b→e channel and measurement of B0-antiB0 mixing parameter with L3 parameter

    International Nuclear Information System (INIS)

    Jezequel, S.

    1992-04-01

    This thesis is based on the analysis of the 1990 and 1991 LEP data taken with the L3 detector. It measures the mixing parameter of the B 0 - anti B 0 system. It consists on the comparison of the relative numbers of dileptons with same signs. After having recalled the theoretical background and previous measurements, it describes precisely the selection of prompt electrons from B hadrons. The muon's one is recalled. Different methods are presented to extract the mixing parameter

  9. Prognostic Value of Volume-Based {sup 18}F-Fluorodeoxyglucose PET/CT Parameters in Patients with Clinically Node-Negative Oral Tongue Squamous Cell Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Su Jin [Dept. of Nuclear Medicine, Ajou University School of Medicine, Suwon (Korea, Republic of); Choi, Joon Young; Lee, Hwan Joo; Hyun, Seung Hyup; Moon, Seung Hwan; Kim, Byung Tae [Dept. of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Baek, Chung Hwan; Son, Young Ik [Dept. of Otorhinolaryngology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2012-11-15

    To evaluate the prognostic value of volume-based metabolic parameters measured with {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography (PET) in patients with clinically node-negative (cN0) oral tongue squamous cell carcinoma (OTSCC) as compared with other prognostic factors. In this study, we included a total of 57 patients who had been diagnosed with cN0 tongue cancer by radiologic, ({sup 18}F-FDG PET/CT, and physical examinations. The maximum standardized uptake value (SUVmax), average SUV (SUVavg), metabolic tumor volume (MTV), and total lesion glycolysis (TLG) for primary tumors were measured with ({sup 18}F-FDG PET. The prognostic significances of these parameters and other clinical variables were assessed by Cox proportional hazards regression analysis. In the univariate analysis, pathological node (pN) stage, American Joint Committee on Cancer (AJCC) stage, SUVmax, SUVavg, MTV, and TLG were significant predictors for survival. On a multivariate analysis, pN stage (hazard ratio = 10.555, p = 0.049), AJCC stage (hazard ratio = 13.220, p = 0.045), and MTV (hazard ratio = 2.698, p 0.033) were significant prognostic factors in cN0 OTSCC patients. The patients with MTV {>=} 7.78 cm{sup 3} showed a worse prognosis than those with MTV < 7.78 cm{sup 3} (p = 0.037). The MTV of primary tumor as a volumetric parameter of ({sup 18}F-FDG PET, in addition to pN stage and AJCC stage, is an independent prognostic factor for survival in cN0 OTSCC.

  10. Measurement of J/ψ resonance parameters

    International Nuclear Information System (INIS)

    Bai Jingzhi; Chen Guangpei; Chen Shaomin

    1995-01-01

    The cross sections of e + e - →hadrons, e + e - , μ + μ - have been measured in the vicinity of J/ψ resonance at BES/BEPC. The fit of the observed cross sections gives the new results of J/ψ resonance parameters: the partial widths to hadrons, electrons and muons are Γ h = 74.1 +- 8.1 keV, Γ e = 5.14 +- 0.39 keV and Γ μ = 5.13 +-0.52 keV respectively; the total width Γ = 84.4 +- 8.9 keV; the branching fractions Γ h /Γ = (87.8 +- 0.5)%, Γ e /Γ (6.09 +- 0.33)%, and Γ μ /Γ = (6.08 +- 0.33)%

  11. Simultaneous measurement of 3 fluctuating plasma parameters

    International Nuclear Information System (INIS)

    Carlson, A.; Giannone, L.

    1991-01-01

    Langmuir triple probes can provide simultaneous measurements of n e , T e and V pl with good temporal and spatial resolution, and therefore are especially suited to detailed investigations of plasma turbulence in the scrape-off-layer. Unfortunately, the finite tip separation coupled with the fluctuating gradients prevents a simple interpretation of the results. We have developed a method using, essentially, two or more triple probes, which allows a good estimate of the three plasma parameters and their spatial derivatives at each point of time (assuming tip separation is much less than correlation length and dimensionless fluctuation levels are much less than unity). In particular, we can unambiguously measure the temperature fluctuations and the turbulent particle and heat flux. (author) 1 fig

  12. Simultaneous measurement of 3 fluctuating plasma parameters

    International Nuclear Information System (INIS)

    Carlson, A.; Giannone, L.

    1991-01-01

    Langmuir triple probes can provide simultaneous measurements of n e , T e , and V pl with good temporal and spatial resolution, and therefore are especially suited to detailed investigations of plasma turbulence in the scrape-off-layer. Unfortunately, the finite tip separation coupled with the fluctuating gradients prevents a simple interpretation of the results. We have developed a method using, essentially, two or more triple probes, which allows a good estimate of the three plasma parameters and their spatial derivatives at each point of time (assuming tip separation is much less than correlation length and dimensionless fluctuation levels are much less than unity). In particular, we can unambiguously measure the temperature fluctuations and the turbulent particle and heat flux. (orig.)

  13. Simultaneous measurement of 3 fluctuating plasma parameters

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, A; Giannone, L. (Max-Planck-Institut fuer Plasmaphysik, Garching (Germany))

    1991-01-01

    Langmuir triple probes can provide simultaneous measurements of n[sub e], T[sub e] and V[sub pl] with good temporal and spatial resolution, and therefore are especially suited to detailed investigations of plasma turbulence in the scrape-off-layer. Unfortunately, the finite tip separation coupled with the fluctuating gradients prevents a simple interpretation of the results. We have developed a method using, essentially, two or more triple probes, which allows a good estimate of the three plasma parameters and their spatial derivatives at each point of time (assuming tip separation is much less than correlation length and dimensionless fluctuation levels are much less than unity). In particular, we can unambiguously measure the temperature fluctuations and the turbulent particle and heat flux. (author) 1 fig.

  14. Reliability analysis of a sensitive and independent stabilometry parameter set.

    Science.gov (United States)

    Nagymáté, Gergely; Orlovits, Zsanett; Kiss, Rita M

    2018-01-01

    Recent studies have suggested reduced independent and sensitive parameter sets for stabilometry measurements based on correlation and variance analyses. However, the reliability of these recommended parameter sets has not been studied in the literature or not in every stance type used in stabilometry assessments, for example, single leg stances. The goal of this study is to evaluate the test-retest reliability of different time-based and frequency-based parameters that are calculated from the center of pressure (CoP) during bipedal and single leg stance for 30- and 60-second measurement intervals. Thirty healthy subjects performed repeated standing trials in a bipedal stance with eyes open and eyes closed conditions and in a single leg stance with eyes open for 60 seconds. A force distribution measuring plate was used to record the CoP. The reliability of the CoP parameters was characterized by using the intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimal detectable change (MDC), coefficient of variation (CV) and CV compliance rate (CVCR). Based on the ICC, SEM and MDC results, many parameters yielded fair to good reliability values, while the CoP path length yielded the highest reliability (smallest ICC > 0.67 (0.54-0.79), largest SEM% = 19.2%). Usually, frequency type parameters and extreme value parameters yielded poor reliability values. There were differences in the reliability of the maximum CoP velocity (better with 30 seconds) and mean power frequency (better with 60 seconds) parameters between the different sampling intervals.

  15. Reliability analysis of a sensitive and independent stabilometry parameter set

    Science.gov (United States)

    Nagymáté, Gergely; Orlovits, Zsanett

    2018-01-01

    Recent studies have suggested reduced independent and sensitive parameter sets for stabilometry measurements based on correlation and variance analyses. However, the reliability of these recommended parameter sets has not been studied in the literature or not in every stance type used in stabilometry assessments, for example, single leg stances. The goal of this study is to evaluate the test-retest reliability of different time-based and frequency-based parameters that are calculated from the center of pressure (CoP) during bipedal and single leg stance for 30- and 60-second measurement intervals. Thirty healthy subjects performed repeated standing trials in a bipedal stance with eyes open and eyes closed conditions and in a single leg stance with eyes open for 60 seconds. A force distribution measuring plate was used to record the CoP. The reliability of the CoP parameters was characterized by using the intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimal detectable change (MDC), coefficient of variation (CV) and CV compliance rate (CVCR). Based on the ICC, SEM and MDC results, many parameters yielded fair to good reliability values, while the CoP path length yielded the highest reliability (smallest ICC > 0.67 (0.54–0.79), largest SEM% = 19.2%). Usually, frequency type parameters and extreme value parameters yielded poor reliability values. There were differences in the reliability of the maximum CoP velocity (better with 30 seconds) and mean power frequency (better with 60 seconds) parameters between the different sampling intervals. PMID:29664938

  16. Research On The Measure Method Of Oblique Pinhole Parameters

    Directory of Open Access Journals (Sweden)

    Ma Yu-Zhen

    2016-01-01

    Full Text Available There are many special advantages in measuring the diameter of blind and deep holes with a capacitive probe, there are still some challenges for the measurement of a oblique pinhole parameters because the measuring device is inconvenient to stretch into the oblique pinhole exactly. A five-dimensional measurement system was adopted in the paper which included a capacitive sensor probe and a three-coordinate measuring machine to accomplish the measurement for oblique pinholes. With the help of the three-dimensional coordinates measured from the pinhole axis, we put forward a comprehensive method of combining the projection method and the least squares method together for fitting spatial straight line to obtain the optimal equation of the spacial axis. Finally, a reliable and entire measurement system was set up.

  17. Patients’ perceived value of pharmacy quality measures: a mixed-methods study

    Science.gov (United States)

    Shiyanbola, Olayinka O; Mort, Jane R

    2015-01-01

    Objective To describe patients’ perceived value and use of quality measures in evaluating and choosing community pharmacies. Design Focus group methodology was combined with a survey tool. During the focus groups, participants assessed the value of the Pharmacy Quality Alliance's quality measures in evaluating and choosing a pharmacy. Also, participants completed questionnaires rating their perceived value of quality measures in evaluating a pharmacy (1 being low value and 5 being high) or choosing a pharmacy (yes/no). Thematic analysis and descriptive statistics were used to analyse the focus groups and surveys, respectively. Setting Semistructured focus groups were conducted in a private meeting space of an urban and a rural area of a Mid-western State in the USA. Participants Thirty-four adults who filled prescription medications in community pharmacies for a chronic illness were recruited in community pharmacies, senior centres and public libraries. Results While comments indicated that all measures were important, medication safety measures (eg, drug-drug interactions) were valued more highly than others. Rating of quality measure utility in evaluating a pharmacy ranged from a mean of 4.88 (‘drug-drug interactions’) to a mean of 4.0 (‘absence of controller therapy for patients with asthma’). Patients were hesitant to use quality information in choosing a pharmacy (depending on the participant's location) but might consider if moving to a new area or having had a negative pharmacy experience. Use of select quality measures to choose a pharmacy ranged from 97.1% of participants using ‘drug-drug interactions’ (medication safety measure) to 55.9% using ‘absence of controller therapy for patients with asthma’. Conclusions The study participants valued quality measures in evaluating and selecting a community pharmacy, with medication safety measures valued highest. The participants reported that the quality measures would not typically cause a

  18. A New Measure of Traditional Values Across Cultures: China and Russia Compared

    Directory of Open Access Journals (Sweden)

    Robert J. Taormina

    2016-10-01

    Full Text Available A new measure of adherence to traditional values was created with the objective of facilitating research within and across cultures and nations. The measure was tested in China (N = 321 and Russia (N = 314 and factor analysis of the data revealed two subscales named Personal Traditional Values (10 items and Public Traditional Values (6 items. Empirical psychometric testing of the overall 16-item measure and the two subscales strongly supported the validity and reliability of all three measures. Means comparisons conducted to assess how well the measures could be used for cross-cultural comparisons revealed the Russians somewhat more than the Chinese living by traditional values overall, both nations about equal on living according to traditional values in their personal lives, and the Russians significantly more inclined to abide by traditional values in public. Also tested were several social and psychological variables as theoretical predictors of living by traditional values, and Life Satisfaction was tested as a possible correlate of living according to traditional values. Regression analyses on the combined data confirmed that Family Emotional Support, Conscientiousness, Collectivism, and Age were all significant positive predictors of living by traditional values. Additional regressions also found some unique predictors for each nation. These findings and the results of the parametric tests support the use of the new scales for measuring traditional values both within and across cultures.

  19. Converter for Measurement of non-sinusoidal current peak value

    DEFF Research Database (Denmark)

    Butvin, P.; Nielsen, Otto V; Brauer, Peter

    1997-01-01

    A linear-response toroid with core wound of rapidly quenched soft magnetic metallic ribbon and fitted with two windings is used to enable correct measurement of mean peak value of non-sinusoidal and not noise-free alternating current.......A linear-response toroid with core wound of rapidly quenched soft magnetic metallic ribbon and fitted with two windings is used to enable correct measurement of mean peak value of non-sinusoidal and not noise-free alternating current....

  20. Parameter Estimation for Improving Association Indicators in Binary Logistic Regression

    Directory of Open Access Journals (Sweden)

    Mahdi Bashiri

    2012-02-01

    Full Text Available The aim of this paper is estimation of Binary logistic regression parameters for maximizing the log-likelihood function with improved association indicators. In this paper the parameter estimation steps have been explained and then measures of association have been introduced and their calculations have been analyzed. Moreover a new related indicators based on membership degree level have been expressed. Indeed association measures demonstrate the number of success responses occurred in front of failure in certain number of Bernoulli independent experiments. In parameter estimation, existing indicators values is not sensitive to the parameter values, whereas the proposed indicators are sensitive to the estimated parameters during the iterative procedure. Therefore, proposing a new association indicator of binary logistic regression with more sensitivity to the estimated parameters in maximizing the log- likelihood in iterative procedure is innovation of this study.

  1. Estimation of intra-operator variability in perfusion parameter measurements using DCE-US.

    Science.gov (United States)

    Gauthier, Marianne; Leguerney, Ingrid; Thalmensi, Jessie; Chebil, Mohamed; Parisot, Sarah; Peronneau, Pierre; Roche, Alain; Lassau, Nathalie

    2011-03-28

    To investigate intra-operator variability of semi-quantitative perfusion parameters using dynamic contrast-enhanced ultrasonography (DCE-US), following bolus injections of SonoVue(®). The in vitro experiments were conducted using three in-house sets up based on pumping a fluid through a phantom placed in a water tank. In the in vivo experiments, B16F10 melanoma cells were xenografted to five nude mice. Both in vitro and in vivo, images were acquired following bolus injections of the ultrasound contrast agent SonoVue(®) (Bracco, Milan, Italy) and using a Toshiba Aplio(®) ultrasound scanner connected to a 2.9-5.8 MHz linear transducer (PZT, PLT 604AT probe) (Toshiba, Japan) allowing harmonic imaging ("Vascular Recognition Imaging") involving linear raw data. A mathematical model based on the dye-dilution theory was developed by the Gustave Roussy Institute, Villejuif, France and used to evaluate seven perfusion parameters from time-intensity curves. Intra-operator variability analyses were based on determining perfusion parameter coefficients of variation (CV). In vitro, different volumes of SonoVue(®) were tested with the three phantoms: intra-operator variability was found to range from 2.33% to 23.72%. In vivo, experiments were performed on tumor tissues and perfusion parameters exhibited values ranging from 1.48% to 29.97%. In addition, the area under the curve (AUC) and the area under the wash-out (AUWO) were two of the parameters of great interest since throughout in vitro and in vivo experiments their variability was lower than 15.79%. AUC and AUWO appear to be the most reliable parameters for assessing tumor perfusion using DCE-US as they exhibited the lowest CV values.

  2. The EURISOL Beta-beam Facility: Parameter and Intensity Values, Version 2

    CERN Document Server

    Benedikt, M; Lindroos, M; Fabich, A

    An initial “bottom-up” analysis of ion intensities along the accelerator chain is revised to take into account more recent simulations of the stacking of 18Ne ions in the decay ring and beneficial trends in output flux as functions of certain machine parameters. In addition, space charge detuning at injection in the PS has led to a rethink of the top energy of the RCS, while that at injection in the SPS has had an impact on the number of bunches per batch delivered by the PS. We present transverse emittance values (which enter the space charge tune shift calculations) together with an updated list of intensities for both ion species under consideration in the baseline scenario.

  3. Comparison of measurement- and proxy-based Vs30 values in California

    Science.gov (United States)

    Yong, Alan K.

    2016-01-01

    This study was prompted by the recent availability of a significant amount of openly accessible measured VS30 values and the desire to investigate the trend of using proxy-based models to predict VS30 in the absence of measurements. Comparisons between measured and model-based values were performed. The measured data included 503 VS30 values collected from various projects for 482 seismographic station sites in California. Six proxy-based models—employing geologic mapping, topographic slope, and terrain classification—were also considered. Included was a new terrain class model based on the Yong et al. (2012) approach but recalibrated with updated measured VS30 values. Using the measured VS30 data as the metric for performance, the predictive capabilities of the six models were determined to be statistically indistinguishable. This study also found three models that tend to underpredict VS30 at lower velocities (NEHRP Site Classes D–E) and overpredict at higher velocities (Site Classes B–C).

  4. Ultrasonic motion analysis system - measurement of temporal and spatial gait parameters

    NARCIS (Netherlands)

    Huitema, RB; Hof, AL; Postema, K

    The duration of stance and swing phase and step and stride length are important parameters in human gait. In this technical note a low-cost ultrasonic motion analysis system is described that is capable of measuring these temporal and spatial parameters while subjects walk on the floor. By using the

  5. CHALLENGES INCURRED IN THE AUDITING OF FAIR VALUE MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    Silviu-Virgil Chiriac

    2016-07-01

    Full Text Available The purpose of the auditors' work is to establish confidence between the producers and users of accounting information. Thus, auditors help protect the interests of different categories of beneficiaries of accounting information when they make economic decisions. The prevalence of fair values in the financial statements as their inherent measurement uncertainty has increased dramatically in recent years and is recognized as representing a significant problem for regulators. In these circumstances we ask which are the difficulties encountered by auditors in auditing fair values, what kinds of deficiencies they find within auditing and whether the complexity of measurements of fair value jeopardizes the ability of auditors to give a highly secure opinion.

  6. Analysis of ESR measurement parameters for detecting irradiated spices

    International Nuclear Information System (INIS)

    Kameya, Hiromi; Hagiwara, Shoji; Todoriki, Setsuko

    2015-01-01

    The side signals from irradiated cellulose radical are used for detecting irradiated spices with the electron spin resonance (ESR). The side signals are two signals observed on both sides of a singlet signal (g≒2.00) from organic free radicals. Since the intensities of the side signals are weak, if the width of the singlet signal is large, these signals are covered and cannot be observed. In this study, we analyzed ESR measurement parameters of seven kinds spices (oregano, basil, parsley, coriander, cumin, white pepper, and black pepper) that would lead to narrow width of the singlet signal for detecting side signals. The results were as follows: 4 mW microwave power for basil, parsley, oregano, coriander, and cumin, and 8 mW for white pepper and black pepper, while modulation amplitude of 4 G, time constant of 20 ms were determined to be the optimal ESR measurement parameters. (author)

  7. Optimal Design of Measurement Programs for the Parameter Identification of Dynamic Systems

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning; Sørensen, John Dalsgaard; Brincker, Rune

    The design of a measured program devoted to parameter identification of structural dynamic systems is considered, the design problem is formulated as an optimization problem due to minimize the total expected cost of the measurement program. All the calculations are based on a priori knowledge...... and engineering judgement. One of the contribution of the approach is that the optimal nmber of sensors can be estimated. This is sown in an numerical example where the proposed approach is demonstrated. The example is concerned with design of a measurement program for estimating the modal damping parameters...

  8. Value measurement of nuclear medicine procedures

    International Nuclear Information System (INIS)

    Potchen, E.J.; Harris, G.I.; Schonbein, W.R.; Rashford, N.J.

    1977-01-01

    The difficulty in measuring the benefit component for cost/benefit analysis of diagnostic procedures in medicine is portrayed as a complex issue relating the objective of intent to a classification of types of decisions a physician must make in evaluating a patient's problem. Ultimately, it seems desirable to develop measuring instruments such as attitude measurement tools by which the relative value of alternative diagnostic procedures could be measured in terms of what they contribute to diminishing the patient's personal perception of disease. Even without this idealized objective, it is reasonable to assume that diagnostic tests which do not contain information, defined as a change in the randomness of a state of knowledge, could not be expected to ultimately benefit the patient. Thus diagnostic information should provide a rational direction for the physician to modify the course of the patient's illness. Since information can be measured as a change in randomness of a knowledge state, we can determine the information content of a specific nuclear medicine procedure when faced with an array of diagnostic problems. These measurements remain to be made for clinical nuclear medicine procedures and are currently under study

  9. The Impact of Political Context on the Measurement of Postmaterial Values

    Directory of Open Access Journals (Sweden)

    Bruce Tranter

    2015-06-01

    Full Text Available This research highlights the influence of political context upon the measurement of postmaterial value orientations. Drawing upon a variety of international survey data, Inglehart claims that since World War II a shift has occurred in advanced industrialized nations from material toward postmaterial values. However, cross-sectional data from Australian Election Study surveys collected over more than two decades indicate that atypically for an advanced democracy, Australian value orientations tend toward the materialist pole. Australian Election Study values estimates are also at odds with those from other national social surveys that portray Australia as a far more postmaterialist nation. Regression analysis demonstrates that after controlling for election issues, attitudes toward political leaders, political party identification, and social background, predicted values estimates are substantially more postmaterial than the raw estimates. The findings have international implications as they suggest that measuring values during or soon after election campaigns may affect the measurement of postmaterial value orientations.

  10. Information-Measuring System to Control the Electrical and Mechanical Motor Parameters

    Directory of Open Access Journals (Sweden)

    K. S. Ermakov

    2015-01-01

    Full Text Available The article considers the issue of creating an information-measuring system for an asynchronous motor. The presented system allows ensuring the failure-free protection of electromotor, considerably reducing costs of its unplanned repair, and reduced economical loss from idle time of the electric motor.The developed system comprises a mathematical model and two subsystems to measure electrical and mechanical parameters of the asynchronous motor.The electrical subsystem comprises a FLUKE company recording multi-meter a signal from which passes through the block of intervals and coding and comes to PC.The mechanical subsystem uses technical tools of phase-chronometric method. This method developed at the department of Metrology and Interchangeability allows an increasing efficiency of developed informative-measuring system. Mathematical modeling is used to link information from subsystems (electrical and mechanical to electromotor construction.The work conducted mathematical modeling of some defects of electric motor, namely: rupture of rotor winding and line surge.The mathematical model in Mathcad was based on a modified formula of Kloss. It allows us to tie the average current value of the torque of the induction motor with shaft speed and take into account the effect of the frequency and voltage.The Matlab Simulink (the package for visual programming environment was used to simulate a rupture of the rotor winding. Simulation results showed how the phase currents of the electric motor changed with the winding rupture.The developed information-measuring system has a number of advantages over traditional systems used in this field (vibration-based diagnostics systems. It will allow an increasing efficiency of the system for diagnostics of electrical machines created on the basis of this information-measuring system.

  11. Value for money: Defining and measuring 'value' in MoD's acquisition policy of obtaining best value for money

    OpenAIRE

    Weiss, A.

    2006-01-01

    Obtaining value for money is a keystone of UK Ministry of Defence (MoD) acquisition strategy embedded in its Smart Acquisition policy. This thesis examines how best to measure the relative value of competing tender submissions for major projects. There is a comprehensive discussion of a wide range of relevant definitions and over three dozen documents are scrutinised including just some sixteen published by the Government. Commercially available models, algorithms and software are examined as...

  12. Constraints on a generalized deceleration parameter from cosmic chronometers

    Science.gov (United States)

    Mamon, Abdulla Al

    2018-04-01

    In this paper, we have proposed a generalized parametrization for the deceleration parameter q in order to study the evolutionary history of the universe. We have shown that the proposed model can reproduce three well known q-parametrized models for some specific values of the model parameter α. We have used the latest compilation of the Hubble parameter measurements obtained from the cosmic chronometer (CC) method (in combination with the local value of the Hubble constant H0) and the Type Ia supernova (SNIa) data to place constraints on the parameters of the model for different values of α. We have found that the resulting constraints on the deceleration parameter and the dark energy equation of state support the ΛCDM model within 1σ confidence level at the present epoch.

  13. Predictive value of some hematological parameters for non-invasive and invasive mole pregnancies.

    Science.gov (United States)

    Abide Yayla, Cigdem; Özkaya, Enis; Yenidede, Ilter; Eser, Ahmet; Ergen, Evrim Bostancı; Tayyar, Ahter Tanay; Şentürk, Mehmet Baki; Karateke, Ates

    2018-02-01

    The aim of this study was to discriminate mole pregnancies and invasive forms among cases with first trimester vaginal bleeding by the utilization of some complete blood count parameters conjunct to sonographic findings and beta human chorionic gonadotropin concentration. Consecutive 257 cases with histopathologically confirmed mole pregnancies and 199 women without mole pregnancy presented with first trimester vaginal bleeding who admitted to Zeynep Kamil Women and Children's Health Training Hospital between January 2012 and January 2016 were included in this cross-sectional study. The serum beta HCG level at presentation, and beta hCG levels at 1st, 2nd and 3rd weeks of postevacuation with some parameters of complete blood count were utilized to discriminate cases with molar pregnancy and cases with invasive mole among first trimester pregnants presented with vaginal bleeding and abnormal sonographic findings. Levels of beta hCG at baseline (AUC = 0.700, p < 0.05) and 1st (AUC = 0.704, p < 0.05), 2nd (AUC = 0.870, p < 0.001) and 3rd (AUC = 0.916, p < 0.001) weeks of postevacuation period were significant predictors for the cases with persistent disease. While area under curve for mean platelet volume is 0.715, it means that mean platelet volume has 21.5% additional diagnostic value for predicting persistency in molar patients. For 8.55 cut-off point for mean platelet volume, sensitivity is 84.6% and specificity is 51.6%. Area under curve for platelet/lymphocyte ratio is 0.683 means that platelet/lymphocyte ratio has additional 18.3% diagnostic value. For 102.25 cut-off point sensitivity is 86.6% and specificity is 46.2. Simple, widely available complete blood count parameters may be used as an adjunct to other risk factors to diagnose molar pregnancies and predict postevacuation trophoblastic disease.

  14. How to measure customer value and its relationship with shareholder value in a business-to-business market

    Directory of Open Access Journals (Sweden)

    Gustavo Bermejo

    2010-10-01

    Full Text Available Intangible assets are difficult to measure, but nowadays the value of the shares of firms in the stock exchange market contains a high percentage of intangible capital and customers are one of the main intangible assets which should be evaluated. This paper presents and discusses some tools to measure the value of customers. But first, it is mandatory to define and clarify the relationships among the concepts of Customer Equity (CE, Life Time Value (LTV and Customer Relationship Management (CRM. LTV is the best financial outcome to measure customer value, so the paper reviews the literature on some mathematical models to calculate LTV. We propose an equation for LTV in order to apply it in a business-to-business market, and an analysis of the influence factors involved in it is made, focusing especially in the link between LTV and shareholder value. Finally, we propose as future lines of research, the relational equity approach as the perfect complement to the customer equity analysis and a way to estimate LTV for actual cases of publicly traded firms using published information.

  15. Uncertainty estimation of core safety parameters using cross-correlations of covariance matrix

    International Nuclear Information System (INIS)

    Yamamoto, A.; Yasue, Y.; Endo, T.; Kodama, Y.; Ohoka, Y.; Tatsumi, M.

    2012-01-01

    An uncertainty estimation method for core safety parameters, for which measurement values are not obtained, is proposed. We empirically recognize the correlations among the prediction errors among core safety parameters, e.g., a correlation between the control rod worth and assembly relative power of corresponding position. Correlations of uncertainties among core safety parameters are theoretically estimated using the covariance of cross sections and sensitivity coefficients for core parameters. The estimated correlations among core safety parameters are verified through the direct Monte-Carlo sampling method. Once the correlation of uncertainties among core safety parameters is known, we can estimate the uncertainty of a safety parameter for which measurement value is not obtained. Furthermore, the correlations can be also used for the reduction of uncertainties of core safety parameters. (authors)

  16. Determination of the kinetic parameters of the CALIBAN metallic core reactor from stochastic neutron measurements

    Energy Technology Data Exchange (ETDEWEB)

    Casoli, P.; Authier, N.; Chapelle, A. [Commissariat a l' Energie Atomique et Aux Energies Alternatives, CEA, DAM, F-21120 Is sur Tille (France)

    2012-07-01

    Several experimental devices are operated by the Criticality and Neutron Science Research Dept. of the CEA Valduc Laboratory. One of these is the Caliban metallic core reactor. The purpose of this study is to develop and perform experiments allowing to determinate some of fundamental kinetic parameters of the reactor. The prompt neutron decay constant and particularly its value at criticality can be measured with reactor noise techniques such as Rossi-{alpha} and Feynman variance-to-mean methods. Subcritical, critical, and even supercritical experiments were performed. Fission chambers detectors were put nearby the core and measurements were analyzed with the Rossi-{alpha} technique. A new value of the prompt neutron decay constant at criticality was determined, which allows, using the Nelson number method, new evaluations of the effective delayed neutron fraction and the in core neutron lifetime. As an introduction of this paper, some motivations of this work are given in part 1. In part 2, principles of the noise measurements experiments performed at the CEA Valduc Laboratory are reminded. The Caliban reactor is described in part 3. Stochastic neutron measurements analysis techniques used in this study are then presented in part 4. Results of fission chamber experiments are summarized in part 5. Part 6 is devoted to the current work, improvement of the experimental device using He 3 neutron detectors and first results obtained with it. Finally, conclusions and perspectives are given in part 7. (authors)

  17. Polarisation parameter measurement in the proton-proton elastic scattering from 0.5 to 1.2 GeV

    International Nuclear Information System (INIS)

    Ducros, Yves

    1970-01-01

    The angular distribution of the polarisation parameter was measured in the proton-proton elastic - scattering at seven energies between 0.5 and 1.2 GeV. A polarized proton target was used. The results show a maximum of the polarisation parameter of 0.6, at 0.73 GeV. This maximum is due to the important increase of the total cross section between 0.6 and 0.73 GeV. At 1.2 GeV the angular distribution of the polarisation shows a minimum for a momentum transfer value of -1 (GeV/c) 2 . A phase shift analysis was done at 0.66 GeV, using all available experimental data at this energy. There is no evidence of a di-baryonic resonance in the 1 D 2 phase. (author) [fr

  18. Fair Value Accounting and Measurement through FASB’s Developments

    OpenAIRE

    Bonaci, Carmen Giorgiana; Strouhal, Jiří; Matis, Dumitru

    2009-01-01

    Our research follows the path of fair value as a term and concept, as well as its disclosure, measurement and recognition back from 1953 until our days, and analyzes the regulations issued by United States Accounting Standard setters, through the point of view of the historical events, which led to their appearance. Our study brings its’ contribution to complementing growing literature on the value relevance of fair value, but focuses on the assessment of fair value as a financial reporting s...

  19. Critical parameters for ammonia

    Energy Technology Data Exchange (ETDEWEB)

    Sato, M. [Center for Mechanical Engineering and Applied Mechanics, Keio University, Hiyoshi 3-14-1, Kohoku-ku, Yokohama 223-8522 (Japan); Masui, G. [Center for Mechanical Engineering and Applied Mechanics, Keio University, Hiyoshi 3-14-1, Kohoku-ku, Yokohama 223-8522 (Japan); Uematsu, M. [Center for Mechanical Engineering and Applied Mechanics, Keio University, Hiyoshi 3-14-1, Kohoku-ku, Yokohama 223-8522 (Japan)]. E-mail: uematsu@mech.keio.ac.jp

    2005-09-15

    (p, {rho}, T) measurements and visual observations of the meniscus for ammonia were carried out carefully in the critical region over the range of temperatures: -1 K (T - T {sub c}) 0.04 K, and of densities: -19 kg . m{sup -3} ({rho} - {rho} {sub c}) 19 kg . m{sup -3} by a metal-bellows volumometer with an optical cell. Vapor pressures were also measured at T = (310, 350, and 400) K. The critical parameters of T {sub c} and {rho} {sub c} were determined based on the results of observation of the critical opalescence. The critical pressure p {sub c} was determined from the present measurements at T {sub c} on the vapor pressure curve. Comparisons of the critical parameters with values given in the literature are presented.

  20. International Accounting Convergence in the Field of Fair Value Measurement

    Directory of Open Access Journals (Sweden)

    Diana Cozma Ighian

    2015-09-01

    Full Text Available The investors’ desire for high-quality, internationally comparable financial information that is useful for decision-making in increasingly global capital markets imposed an international convergence, the ultimate goal of which is a single set of international accounting standards that companies worldwide would use for both domestic and cross-border financial reporting. The guidance, set out in IFRS 13 Fair Value Measurement and the update to Topic 820 (formerly referred to as SFAS 157, completes a major project of the boards’ joint work to improve IFRSs and US GAAP and to bring about their convergence. This article describes the controversial history of fair value measurement and the main novelties in the field of fair value measurement, arising from the international convergence process.

  1. The use of personal values in living standards measures

    African Journals Online (AJOL)

    2011-08-26

    Aug 26, 2011 ... Values Questionnaire, Living Standards Measure, purchase decision- .... According to Schwartz (1992), scholars in the areas of psychology, anthropology ... The application of the values perspective to the marketing of .... is a fairly complex task involving large data tables, and that some of the LSM groups.

  2. New approach for rapid assessment of trophic status of Yellow Sea and East China Sea using easy-to-measure parameters

    Science.gov (United States)

    Kong, Xianyu; Liu, Yanfang; Jian, Huimin; Su, Rongguo; Yao, Qingzhen; Shi, Xiaoyong

    2017-10-01

    To realize potential cost savings in coastal monitoring programs and provide timely advice for marine management, there is an urgent need for efficient evaluation tools based on easily measured variables for the rapid and timely assessment of estuarine and offshore eutrophication. In this study, using parallel factor analysis (PARAFAC), principal component analysis (PCA), and discriminant function analysis (DFA) with the trophic index (TRIX) for reference, we developed an approach for rapidly assessing the eutrophication status of coastal waters using easy-to-measure parameters, including chromophoric dissolved organic matter (CDOM), fluorescence excitation-emission matrices, CDOM UV-Vis absorbance, and other water-quality parameters (turbidity, chlorophyll a, and dissolved oxygen). First, we decomposed CDOM excitation-emission matrices (EEMs) by PARAFAC to identify three components. Then, we applied PCA to simplify the complexity of the relationships between the water-quality parameters. Finally, we used the PCA score values as independent variables in DFA to develop a eutrophication assessment model. The developed model yielded classification accuracy rates of 97.1%, 80.5%, 90.3%, and 89.1% for good, moderate, and poor water qualities, and for the overall data sets, respectively. Our results suggest that these easy-to-measure parameters could be used to develop a simple approach for rapid in-situ assessment and monitoring of the eutrophication of estuarine and offshore areas.

  3. Measurement of proton-beam parameters by means of digital television diagnostic system

    International Nuclear Information System (INIS)

    Vazhenin, V.A.; Borovkov, S.D.; Evtikhiev, A.V.

    1992-01-01

    A method is described for measurement of the parameters of pulse-packet beams by means of a digital television diagnostic system. Results of tests of the system in measurement of the parameters of a proton beam with an energy of 1.35 GeV in the U-70 circular accelerator and results of measurements of the energy spectrum of the 30-MeV proton beam of the LU-30 linear accelerator are given. The possibility is shown of using the system to measure the integrated characteristics of an entire beam-pulse packet as well as the characteristics of individual pulses with a period of 60 msec. 6 refs., 4 figs., 1 tab

  4. Statistical analysis of dynamic parameters of the core

    International Nuclear Information System (INIS)

    Ionov, V.S.

    2007-01-01

    The transients of various types were investigated for the cores of zero power critical facilities in RRC KI and NPP. Dynamic parameters of neutron transients were explored by tool statistical analysis. Its have sufficient duration, few channels for currents of chambers and reactivity and also some channels for technological parameters. On these values the inverse period. reactivity, lifetime of neutrons, reactivity coefficients and some effects of a reactivity are determinate, and on the values were restored values of measured dynamic parameters as result of the analysis. The mathematical means of statistical analysis were used: approximation(A), filtration (F), rejection (R), estimation of parameters of descriptive statistic (DSP), correlation performances (kk), regression analysis(KP), the prognosis (P), statistician criteria (SC). The calculation procedures were realized by computer language MATLAB. The reasons of methodical and statistical errors are submitted: inadequacy of model operation, precision neutron-physical parameters, features of registered processes, used mathematical model in reactivity meters, technique of processing for registered data etc. Examples of results of statistical analysis. Problems of validity of the methods used for definition and certification of values of statistical parameters and dynamic characteristics are considered (Authors)

  5. Prognostic value of volumetric parameters of {sup 18}F-FDG PET in non-small-cell lung cancer: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Im, Hyung-Jun [Seoul National University Hospital, Department of Nuclear Medicine, 101 Daehak-ro, Jongno-gu, Seoul (Korea, Republic of); Graduate School of Convergence Science and Technology, and College of Medicine or College of Pharmacy, Department of Molecular Medicine and Biopharmaceutical Sciences, Seoul (Korea, Republic of); Pak, Kyoungjune [Seoul National University Hospital, Department of Nuclear Medicine, 101 Daehak-ro, Jongno-gu, Seoul (Korea, Republic of); Pusan National University Hospital, Department of Nuclear Medicine and Biomedical Research Institute, Busan (Korea, Republic of); Cheon, Gi Jeong; Kang, Keon Wook; Chung, June-Key [Seoul National University Hospital, Department of Nuclear Medicine, 101 Daehak-ro, Jongno-gu, Seoul (Korea, Republic of); Seoul National University Hospital, Cancer Research Institute, Seoul (Korea, Republic of); Kim, Seong-Jang; Kim, In-Joo [Pusan National University Hospital, Department of Nuclear Medicine and Biomedical Research Institute, Busan (Korea, Republic of); Kim, E.E. [Graduate School of Convergence Science and Technology, and College of Medicine or College of Pharmacy, Department of Molecular Medicine and Biopharmaceutical Sciences, Seoul (Korea, Republic of); University of California at Irvine, Department of Radiological Science, California, CA (United States); Lee, Dong Soo [Seoul National University Hospital, Department of Nuclear Medicine, 101 Daehak-ro, Jongno-gu, Seoul (Korea, Republic of); Graduate School of Convergence Science and Technology, and College of Medicine or College of Pharmacy, Department of Molecular Medicine and Biopharmaceutical Sciences, Seoul (Korea, Republic of); Seoul National University Hospital, Cancer Research Institute, Seoul (Korea, Republic of)

    2014-09-06

    We conducted a comprehensive systematic review of the literature on volumetric parameters from {sup 18}F-FDG PET and a meta-analysis of the prognostic value of metabolic tumour volume (MTV) and total lesion glycolysis (TLG) in patients with lung cancer. A systematic search of MEDLINE and EMBASE was performed using the keywords ''positron emission tomography (PET)'', ''lung cancer'', and ''volume''. Inclusion criteria were: {sup 18}F-FDG PET used as an initial imaging tool; studies limited to non-small-cell lung cancer (NSCLC); volume measurement of lung cancer; patients who had not undergone surgery, chemotherapy, or radiotherapy before the PET scan; and studies that reported survival data. Event-free survival and overall survival were evaluated as outcomes. The impact of MTV and TLG on survival was measured in terms of the hazard ratio (HR) effect size. Data from each study were analysed using Review Manager 5.2. Thirteen eligible studies including 1,581 patients were analysed. Patients with high MTV showed a worse prognosis with an HR of 2.71 (95 % CI 1.82 - 4.02, p < 0.00001) for adverse events and an HR of 2.31 (95 % CI 1.54 - 3.47, p < 0.00001) for death. Patients with high TLG also showed a worse prognosis with an HR of 2.35 (95 % CI 1.91 - 2.89, p < 0.00001) for adverse events and an HR of 2.43 (95 % CI 1.89 - 3.11, p < 0.00001) for death. The prognostic value of MTV and TLG remained significant in a subgroup analysis according to TNM stage as well as the methods for defining cut-off values and tumour delineation. Volumetric parameters from {sup 18}F-FDG PET are significant prognostic factors for outcome in patients with NSCLC. Patients with a high MTV or TLG are at higher risk of adverse events and death. MTV and TLG were significant prognostic factors in patients with TNM stage I/II and stage III/IV NSCLC. (orig.)

  6. Measuruement of transport parameters on multiphase flows

    International Nuclear Information System (INIS)

    Kipphan, H.

    1976-01-01

    A method working on the basis of the correlation measuring technique is developed and tested on gas-solid flows in pipelines to measure transport parameters of the solid phase. Firstly, flows with stationary and site-independent average values are considered; finally, a few data on the measurement of instationary flows follow. (orig.) [de

  7. Prognostic value of 18F-choline PET/CT metabolic parameters in patients with metastatic castration-resistant prostate cancer treated with abiraterone or enzalutamide

    Energy Technology Data Exchange (ETDEWEB)

    Caroli, Paola; Fantini, Lorenzo; Celli, Monica; Paganelli, Giovanni; Matteucci, Federica [Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori (IRST) IRCCS, Nuclear Medicine Unit, Meldola (Italy); De Giorgi, Ugo; Conteduca, Vincenza; Rossi, Lorena [Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori (IRST) IRCCS, Department of Medical Oncology, Meldola (Italy); Scarpi, Emanuela [Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori (IRST) IRCCS, Unit of Biostatistics and Clinical Trials Unit, Meldola (Italy); Moretti, Andrea; Galassi, Riccardo [Morgagni Pierantoni Hospital, Nuclear Medicine Unit, Forli (Italy); Bianchi, Emanuela [Infermi Hospital, Department of Medical Oncology, Rimini (Italy)

    2018-03-15

    The role of 18F-choline positron emission tomography/computed tomography (FCH-PET/CT) in patients with metastatic castration-resistant prostate cancer (mCRPC) has been firmly established in recent years. We analyzed the prognostic value of functional parameters such as mean standardized uptake volume (SUVmean), maximum standardized uptake volume (SUVmax), metabolic total volume (MTV; the volume of interest consisting of all spatially connected voxels within a fixed threshold of 40% of the SUVmax), and total lesion activity (TLA: the product of MTV and mean standardized uptake value) estimated with FCH-PET/CT in mCRPC patients in progression after docetaxel and treated with new antiandrogen receptor therapies, abiraterone or enzalutamide. We retrospectively studied 94 mCRPC patients, mean age 74 years (range 42-90), previously treated with docetaxel who were treated with either abiraterone (n = 52) or enzalutamide (n = 42). An FCH-PET/CT was performed at baseline, and patients were evaluated on a monthly basis for serological PSA response and every 3 months for radiological response. We measured MTV, SUVmean, SUVmax and TLA for each lesion and analyzed the sum of MTV (SMTV), SUVmean (SSUVmean), SUVmax (SSUVmax) and TLA (STLA) values for a maximum of 20 lesions. Univariate analysis was used to correlate these data with PFS and OS. We observed a median SMTV of 130 cm{sup 3}, median SSUVmax of 106.5 and a median STLA of 495,070. All of these parameters were significant for PFS and OS in univariate analysis, while only STLA was significant for PFS and OS in multivariate analysis after adjusting for lesion and age (p < 0.0001 and p = 0.001, respectively). Baseline PSA values maintained a certain reliability for OS (p = 0.034). Semiquantitative parameters of FCH-PET/CT play a prognostic role in mCRCP patients treated with abiraterone or enzalutamide. (orig.)

  8. How to Use Value-Added Measures Right

    Science.gov (United States)

    Di Carlo, Matthew

    2012-01-01

    Value-added models are a specific type of "growth model," a diverse group of statistical techniques to isolate a teacher's impact on his or her students' testing progress while controlling for other measurable factors, such as student and school characteristics, that are outside that teacher's control. Opponents, including many teachers, argue…

  9. COMPREHENSIVE CHECK MEASUREMENT OF KEY PARAMETERS ON MODEL BELT CONVEYOR

    Directory of Open Access Journals (Sweden)

    Vlastimil MONI

    2013-07-01

    Full Text Available Complex measurements of characteristic parameters realised on a long distance model belt conveyor are described. The main objective was to complete and combine the regular measurements of electric power on drives of belt conveyors operated in Czech opencast mines with measurements of other physical quantities and to gain by this way an image of their mutual relations and relations of quantities derived from them. The paper includes a short description and results of the measurements on an experimental model conveyor with a closed material transport way.

  10. Precision neutral current asymmetry parameter measurements from the Tau polarization at LEP

    International Nuclear Information System (INIS)

    Abbiendi, G.; Aakesson, P.F.

    2001-01-01

    Measurements of the τ lepton polarization and forward-backward polarization asymmetry near the Z 0 resonance using the OPAL detector are described. The measurements are based on analyses of τ→ν e ν τ , τ→μν μ ν τ , τ→πν τ , τ→ρν τ and τ→ 1 ν τ decays from a sample of 144,810 e + e - →τ + τ - candidates corresponding to an integrated luminosity of 151 pb -1 . Assuming that the τ lepton decays according to V-A theory, we measure the average τ polarization near √(s) =M Z to be left angle P τ right angle = (-14.10 ±0.73 ±0.55)% and the τ polarization forward-backward asymmetry to be A pol FB = (-10.55 ±0.76 ±0.25)%, where the first error is statistical and the second systematic. Taking into account the small effects of the photon propagator, photon-Z 0 interference and photonic radiative corrections, these results can be expressed in terms of the lepton neutral current asymmetry parameters: A τ =0.1456±0.0076±0.0057, A e =0.1454±0.0108±0.0036. These measurements are consistent with the hypothesis of lepton universality and combine to give A l = 0.1455 ±0.0073. Within the context of the Standard Model this combined result corresponds to =0.23172 ±0.00092. Combing these results with those from the other OPAL neutral current measurements yields a value of =0.23211 ±0.00068. (orig.)

  11. Geoelectrical Measurement of Multi-Scale Mass Transfer Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Day-Lewis, Frederick David [US Geological Survey, Storrs, CT (United States); Singha, Kamini [Colorado School of Mines, Golden, CO (United States); Johnson, Timothy C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Haggerty, Roy [Oregon State Univ., Corvallis, OR (United States); Binley, Andrew [Lancaster Univ. (United Kingdom); Lane, John W. [US Geological Survey, Storrs, CT (United States)

    2014-11-25

    Mass transfer affects contaminant transport and is thought to control the efficiency of aquifer remediation at a number of sites within the Department of Energy (DOE) complex. An improved understanding of mass transfer is critical to meeting the enormous scientific and engineering challenges currently facing DOE. Informed design of site remedies and long-term stewardship of radionuclide-contaminated sites will require new cost-effective laboratory and field techniques to measure the parameters controlling mass transfer spatially and across a range of scales. In this project, we sought to capitalize on the geophysical signatures of mass transfer. Previous numerical modeling and pilot-scale field experiments suggested that mass transfer produces a geoelectrical signature—a hysteretic relation between sampled (mobile-domain) fluid conductivity and bulk (mobile + immobile) conductivity—over a range of scales relevant to aquifer remediation. In this work, we investigated the geoelectrical signature of mass transfer during tracer transport in a series of controlled experiments to determine the operation of controlling parameters, and also investigated the use of complex-resistivity (CR) as a means of quantifying mass transfer parameters in situ without tracer experiments. In an add-on component to our grant, we additionally considered nuclear magnetic resonance (NMR) to help parse mobile from immobile porosities. Including the NMR component, our revised study objectives were to: 1. Develop and demonstrate geophysical approaches to measure mass-transfer parameters spatially and over a range of scales, including the combination of electrical resistivity monitoring, tracer tests, complex resistivity, nuclear magnetic resonance, and materials characterization; and 2. Provide mass-transfer estimates for improved understanding of contaminant fate and transport at DOE sites, such as uranium transport at the Hanford 300 Area. To achieve our objectives, we implemented a 3

  12. Application of function-oriented roughness parameters using confocal microscopy

    Directory of Open Access Journals (Sweden)

    K. Klauer

    2018-06-01

    Full Text Available Optical measuring instruments are widely used for the functional characterization of surface topography. However, due to the interaction of the surface with the incident light, effects occur that can influence the measured topography height values and the obtained surface texture parameters. Therefore, we describe a systematic investigation of the influences of optical surface topography measurement on the acquisition of function-oriented roughness parameters. The same evaluation areas of varying cylinder liners which represent a typical application of function-oriented roughness parameters were measured with a confocal microscope and a stylus instrument. Functional surface texture parameters as given in the standards ISO 13565–2, ISO 13565–3 and ISO 25178–2 were evaluated for both measurement methods and compared. The transmission of specific surface features was described and a correlation analysis for the surface topographies obtained with the different measurement methods and their resulting functional roughness parameters was carried out. Keywords: Functional surface characterization, Optical metrology, Topography measurement, Roughness

  13. Effect of measurement conditions on three-dimensional roughness values, and development of measurement standard

    International Nuclear Information System (INIS)

    Fabre, A; Brenier, B; Raynaud, S

    2011-01-01

    Friction or corrosion behaviour, fatigue lifetime for mechanical components are influenced by their boundary and subsurface properties. The surface integrity is studied on mechanical component in order to improve the service behaviour of them. Roughness is one of the main geometrical properties, which is to be qualified and quantified. Components can be obtained using a complex process: forming, machining and treatment can be combined to realize parts with complex shape. Then, three-dimensional roughness is needed to characterize these parts with complex shape and textured surface. With contact or non-contact measurements (contact stylus, confocal microprobe, interferometer), three-dimensional roughness is quantified using the calculation of pertinent parameters defined by the international standard PR EN ISO 25178-2:2008. An analysis will identify the influence of measurement conditions on three-dimensional parameters. The purpose of this study is to analyse the variation of roughness results using contact stylus or optical apparatus. The second aim of this work is to develop a measurement standard well adapted to qualify the contact and non-contact apparatus.

  14. measurements of distribution coefficients and lipophilicity values

    African Journals Online (AJOL)

    Preferred Customer

    octanol and water, followed by measuring the distribution of the solute in ... Instrumentation and apparatus: HPLC-UV-DAD and HPLC–ESI-MS experiments .... process in the determination of KD and log P values for the HFSLM extracts. ..... Perrin, D.D.; Dempsey, B. Buffers for pH and Metal Ion Control, Chapman and Hall:.

  15. Parameter Estimation of Partial Differential Equation Models.

    Science.gov (United States)

    Xun, Xiaolei; Cao, Jiguo; Mallick, Bani; Carroll, Raymond J; Maity, Arnab

    2013-01-01

    Partial differential equation (PDE) models are commonly used to model complex dynamic systems in applied sciences such as biology and finance. The forms of these PDE models are usually proposed by experts based on their prior knowledge and understanding of the dynamic system. Parameters in PDE models often have interesting scientific interpretations, but their values are often unknown, and need to be estimated from the measurements of the dynamic system in the present of measurement errors. Most PDEs used in practice have no analytic solutions, and can only be solved with numerical methods. Currently, methods for estimating PDE parameters require repeatedly solving PDEs numerically under thousands of candidate parameter values, and thus the computational load is high. In this article, we propose two methods to estimate parameters in PDE models: a parameter cascading method and a Bayesian approach. In both methods, the underlying dynamic process modeled with the PDE model is represented via basis function expansion. For the parameter cascading method, we develop two nested levels of optimization to estimate the PDE parameters. For the Bayesian method, we develop a joint model for data and the PDE, and develop a novel hierarchical model allowing us to employ Markov chain Monte Carlo (MCMC) techniques to make posterior inference. Simulation studies show that the Bayesian method and parameter cascading method are comparable, and both outperform other available methods in terms of estimation accuracy. The two methods are demonstrated by estimating parameters in a PDE model from LIDAR data.

  16. Normative Values for Electrochemical Skin Conductance Measurements for Quantitative Assessment of Sudomotor Function in Healthy Indian Adults.

    Science.gov (United States)

    Shivaprasad, C; Goel, Amit; Vilier, Alice; Calvet, Jean-Henri

    2018-01-01

    Electrochemical skin conductance (ESC) test is a widely accepted objective technique for quantitatively assessing sudomotor dysfunction, which is one of the earliest-detected neurophysiologic abnormalities in diabetic patients with distal symmetric polyneuropathy. This study aimed to provide normative data for ESC values among healthy Indian participants and assess the potential influence of age, sex, and body mass index (BMI) on ESC measurements. A sample of 217 healthy participants aged 18-75 years were recruited and assessed for parameters including age, gender, BMI, and ESC measurements of the hands and feet. The Shapiro-Wilk test was used to assess the normality of the data. Pearson's correlation was used to evaluate the association between age, gender, and BMI, and ESC measurements. The mean age of the participants was 43.3 ± 13.2 years, and mean BMI was 26.0 ± 4.3 kg/m 2 . Mean ESC for the hands and feet was 68.9 ± 13.1 and 71 ± 12.9 micro-Siemens, respectively, and there was a significant correlation between values from the right and left hands and feet ( r = 0.9, P < 0.0001). A significant correlation was also observed between ESC measurements of the hands and feet ( r = 0.94, P < 0.0001). ESC values of both hands and feet declined with age. A weak but significant inverse correlation between ESC and age was observed for the hands ( r = 0.02, P = 0.01) and for the feet ( r = 0.12, P < 0.0001). There was no significant difference in hand or feet ESC measurement between male and female participants. No significant correlation was observed between BMI and ESC of hands or feet. Only age was identified as a significant determinant of ESC on multivariate logistic regression analysis. Normative values for Indians are lower than that reported for Caucasians.

  17. Analysis of glottal source parameters in Parkinsonian speech.

    Science.gov (United States)

    Hanratty, Jane; Deegan, Catherine; Walsh, Mary; Kirkpatrick, Barry

    2016-08-01

    Diagnosis and monitoring of Parkinson's disease has a number of challenges as there is no definitive biomarker despite the broad range of symptoms. Research is ongoing to produce objective measures that can either diagnose Parkinson's or act as an objective decision support tool. Recent research on speech based measures have demonstrated promising results. This study aims to investigate the characteristics of the glottal source signal in Parkinsonian speech. An experiment is conducted in which a selection of glottal parameters are tested for their ability to discriminate between healthy and Parkinsonian speech. Results for each glottal parameter are presented for a database of 50 healthy speakers and a database of 16 speakers with Parkinsonian speech symptoms. Receiver operating characteristic (ROC) curves were employed to analyse the results and the area under the ROC curve (AUC) values were used to quantify the performance of each glottal parameter. The results indicate that glottal parameters can be used to discriminate between healthy and Parkinsonian speech, although results varied for each parameter tested. For the task of separating healthy and Parkinsonian speech, 2 out of the 7 glottal parameters tested produced AUC values of over 0.9.

  18. Influence of lung parameter values for the Brazilian population on inhalation dose

    International Nuclear Information System (INIS)

    Reis, Arlene A.; Lopes, Ricardo T.

    2009-01-01

    The Human Respiratory Tract Model (HRTM) proposed by the ICRP Publication 66 accounts for the morphology and physiology of the respiratory tract. The ICRP 66 presents deposition fraction in the respiratory tract regions considering reference values from Caucasian man. However, in order to obtain a more accurate assessment of intake and dose the ICRP recommends the use of specific information when they are available. The main objective of this study is to evaluate the influence in dose calculation to each region of the respiratory tract when physiological parameters from samples of Brazilian population, in different levels of exercise, are applied in the deposition model.The dosimetric model of HRTM was implemented in the software EXCEL for Windows and committed equivalent dose was determined for each respiratory tract region. First it was calculated the total number of nuclear transformations considering the fractional deposition of activity in each source tissue obtained by application of physiological and morphological Brazilian parameters in the deposition model and then it was calculated the total energy absorbed per unit mass in the target tissue.The variation in the fractional deposition in the compartments of the respiratory tract in changing the physiological parameters from Caucasian to Brazilian adult man causes variation in the number of total transformations and also in the equivalent dose in each region of the respiratory tract. The variations are not the same for all regions of the respiratory tract and depend on levels of exercise. (author)

  19. Characterization of Initial Parameter Information for Lifetime Prediction of Electronic Devices.

    Science.gov (United States)

    Li, Zhigang; Liu, Boying; Yuan, Mengxiong; Zhang, Feifei; Guo, Jiaqiang

    2016-01-01

    Newly manufactured electronic devices are subject to different levels of potential defects existing among the initial parameter information of the devices. In this study, a characterization of electromagnetic relays that were operated at their optimal performance with appropriate and steady parameter values was performed to estimate the levels of their potential defects and to develop a lifetime prediction model. First, the initial parameter information value and stability were quantified to measure the performance of the electronics. In particular, the values of the initial parameter information were estimated using the probability-weighted average method, whereas the stability of the parameter information was determined by using the difference between the extrema and end points of the fitting curves for the initial parameter information. Second, a lifetime prediction model for small-sized samples was proposed on the basis of both measures. Finally, a model for the relationship of the initial contact resistance and stability over the lifetime of the sampled electromagnetic relays was proposed and verified. A comparison of the actual and predicted lifetimes of the relays revealed a 15.4% relative error, indicating that the lifetime of electronic devices can be predicted based on their initial parameter information.

  20. Characterization of Initial Parameter Information for Lifetime Prediction of Electronic Devices.

    Directory of Open Access Journals (Sweden)

    Zhigang Li

    Full Text Available Newly manufactured electronic devices are subject to different levels of potential defects existing among the initial parameter information of the devices. In this study, a characterization of electromagnetic relays that were operated at their optimal performance with appropriate and steady parameter values was performed to estimate the levels of their potential defects and to develop a lifetime prediction model. First, the initial parameter information value and stability were quantified to measure the performance of the electronics. In particular, the values of the initial parameter information were estimated using the probability-weighted average method, whereas the stability of the parameter information was determined by using the difference between the extrema and end points of the fitting curves for the initial parameter information. Second, a lifetime prediction model for small-sized samples was proposed on the basis of both measures. Finally, a model for the relationship of the initial contact resistance and stability over the lifetime of the sampled electromagnetic relays was proposed and verified. A comparison of the actual and predicted lifetimes of the relays revealed a 15.4% relative error, indicating that the lifetime of electronic devices can be predicted based on their initial parameter information.

  1. On Measurement of Helicity Parameters in Top Quark Decay

    OpenAIRE

    Nelson, Charles A.; Adler, Jr, L. J.

    2000-01-01

    To enable an evaluation of future measurements of the helicity parameters for " t --> W b " decay in regard to " T_FS violation", this paper considers the effects of an additional pure-imaginary coupling, (i g/2 Lambda) or (i g), associated with a specific, single additional Lorentz structure, i = S, P, S + P, ... Sizable " T_FS violation" signatures can occur for low-effective mass scales (< 320 GeV), but in most cases can be more simply excluded by 10% precision measurement of the probabili...

  2. Measurement of mixing and CP violation parameters in two-body charm decays

    CERN Document Server

    Aaij, R; Adeva, B; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amhis, Y; Anderson, J; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Arrabito, L; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Bailey, D S; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bates, A; Bauer, C; Bauer, Th; Bay, A; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Benayoun, M; Bencivenni, G; Benson, S; Benton, J; Bernet, R; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blanks, C; Blouw, J; Blusk, S; Bobrov, A; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brook, N H; Brown, H; Büchler-Germann, A; Burducea, I; Bursche, A; Buytaert, J; Cadeddu, S; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carson, L; Carvalho Akiba, K; Casse, G; Cattaneo, M; Cauet, Ch; Charles, M; Charpentier, Ph; Chiapolini, N; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Collins, P; Comerma-Montells, A; Constantin, F; Contu, A; Cook, A; Coombes, M; Corti, G; Cowan, G A; Currie, R; D'Ambrosio, C; David, P; David, P N Y; De Bonis, I; De Capua, S; De Cian, M; De Lorenzi, F; De Miranda, J M; De Paula, L; De Simone, P; Decamp, D; Deckenhoff, M; Degaudenzi, H; Del Buono, L; Deplano, C; Derkach, D; Deschamps, O; Dettori, F; Dickens, J; Dijkstra, H; Diniz Batista, P; Domingo Bonal, F; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Dziurda, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisele, F; Eisenhardt, S; Ekelhof, R; Eklund, L; Elsasser, Ch; Elsby, D; Esperante Pereira, D; Estève, L; Falabella, A; Fanchini, E; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Fernandez Albor, V; Ferro-Luzzi, M; Filippov, S; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Frank, M; Frei, C; Frosini, M; Furcas, S; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garnier, J-C; Garofoli, J; Garra Tico, J; Garrido, L; Gascon, D; Gaspar, C; Gauvin, N; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Gracianiv Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Haefeli, G; Haen, C; Haines, S C; Hampson, T; Hansmann-Menzemer, S; Harji, R; Harnew, N; Harrison, J; Harrison, P F; Hartmann, T; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicks, E; Holubyev, K; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Huston, R S; Hutchcroft, D; Hynds, D; Iakovenko, V; Ilten, P; Imong, J; Jacobsson, R; Jaeger, A; Jahjah Hussein, M; Jans, E; Jansen, F; Jaton, P; Jean-Marie, B; Jing, F; John, M; Johnson, D; Jones, C R; Jost, B; Kaballo, M; Kandybei, S; Karacson, M; Karbach, T M; Keaveney, J; Kenyon, I R; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kim, Y M; Knecht, M; Koppenburg, P; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kruzelecki, K; Kucharczyk, M; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leroy, O; Lesiak, T; Li, L; Li Gioi, L; Lieng, M; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; von Loeben, J; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Lu, H; Luisier, J; Mac Raighne, A; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Magnin, J; Malde, S; Mamunur, R M D; Manca, G; Mancinelli, G; Mangiafave, N; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martin, L; Martín Sánchez, A; Martinez Santos, D; Massafferri, A; Mathe, Z; Matteuzzi, C; Matveev, M; Maurice, E; Maynard, B; Mazurov, A; McGregor, G; McNulty, R; Meissner, M; Merk, M; Merkel, J; Messi, R; Miglioranzi, S; Milanes, D A; Minard, M-N; Molina Rodriguez, J; Monteil, S; Moran, D; Morawski, P; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Muster, B; Musy, M; Mylroie-Smith, J; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Nedos, M; Needham, M; Neufeld, N; Nguyen-Mau, C; Nicol, M; Niess, V; Nikitin, N; Nomerotski, A; Novoselov, A; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Pal, K; Palacios, J; Palano, A; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Paterson, S K; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perego, D L; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petrella, A; Petrolini, A; Phan, A; Picatoste Olloqui, E; Pie Valls, B; Pietrzyk, B; Pilař, T; Pinci, D; Plackett, R; Playfer, S; Plo Casasus, M; Polok, G; Poluektov, A; Polycarpo, E; Popov, D; Popovici, B; Potterat, C; Powell, A; Prisciandaro, J; Pugatch, V; Puig Navarro, A; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Rinnert, K; Roa Romero, D A; Robbe, P; Rodrigues, E; Rodrigues, F; Rodriguez Perez, P; Rogers, G J; Roiser, S; Romanovsky, V; Rosello, M; Rouvinet, J; Ruf, T; Ruiz, H; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salzmann, C; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santinelli, R; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schleich, S; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M -H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Skwarnicki, T; Smith, A C; Smith, N A; Smith, E; Sobczak, K; Soler, F J P; Solomin, A; Soomro, F; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Subbiah, V K; Swientek, S; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Topp-Joergensen, S; Torr, N; Tournefier, E; Tran, M T; Tsaregorodtsev, A; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urquijo, P; Uwer, U; Vagnoni, V; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; Velthuis, J J; Veltri, M; Viaud, B; Videau, I; Vilasis-Cardona, X; Visniakov, J; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Voss, H; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Webber, A D; Websdale, D; Whitehead, M; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wishahi, J; Witek, M; Witzeling, W; Wotton, S A; Wyllie, K; Xie, Y; Xing, F; Xing, Z; Yang, Z; Young, R; Yushchenko, O; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhong, L; Zverev, E; Zvyagin, A

    2012-01-01

    A study of mixing and indirect CP violation in $D^0$ mesons through the determination of the parameters $y_{CP}$ and $A_\\Gamma$ is presented. The parameter $y_{CP}$ is the deviation from unity of the ratio of effective lifetimes measured in $D^0$ decays to the CP eigenstate $K^+K^-$ with respect to decays to the Cabibbo favoured mode $K^-\\pi^+$. The result measured using data collected by LHCb in 2010, corresponding to an integrated luminosity of $29~pb^{-1}$, is $$y_{CP} = (5.5\\pm6.3_{\\rm stat}\\pm4.1_{\\rm syst})\\times 10^{-3}.$$ The parameter $A_\\Gamma$ is the asymmetry of effective lifetimes measured in decays of $D^0$ and $\\overline{D}^0$ mesons to $K^+K^-$. The result is $$A_\\Gamma = (-5.9\\pm5.9_{\\rm stat}\\pm2.1_{\\rm syst})\\times 10^{-3}.$$ A data-driven technique is used to correct for lifetime-biasing effects.

  3. A Comparative Study of Distribution System Parameter Estimation Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yannan; Williams, Tess L.; Gourisetti, Sri Nikhil Gup

    2016-07-17

    In this paper, we compare two parameter estimation methods for distribution systems: residual sensitivity analysis and state-vector augmentation with a Kalman filter. These two methods were originally proposed for transmission systems, and are still the most commonly used methods for parameter estimation. Distribution systems have much lower measurement redundancy than transmission systems. Therefore, estimating parameters is much more difficult. To increase the robustness of parameter estimation, the two methods are applied with combined measurement snapshots (measurement sets taken at different points in time), so that the redundancy for computing the parameter values is increased. The advantages and disadvantages of both methods are discussed. The results of this paper show that state-vector augmentation is a better approach for parameter estimation in distribution systems. Simulation studies are done on a modified version of IEEE 13-Node Test Feeder with varying levels of measurement noise and non-zero error in the other system model parameters.

  4. Investigation of metrological parameters of measuring system for small temperature changes

    Directory of Open Access Journals (Sweden)

    Samynina M. G.

    2014-02-01

    Full Text Available Metrological parameters of the non-standard contact device were investigated to characterize its performance in temperature change measurements in the specified temperature range. Several series thermistors with a negative temperature coefficient of resistance connected into a linearization circuit were used as the sensing element of the semiconductor device. Increasing the number of thermistors leads to improved circuitry resolving power and reduced dispersion of this parameter. However, there is the question of optimal ratio of the number of thermistors and implemented temperature resolution, due to the nonlinear resolution dependence of the number of series-connected thermoelements. An example of scheme of four similar thermistors as the primary sensor and of a standard measuring instrument, which is working in ohmmeter mode, shows the ability to measure temperature changes at the level of hundredth of a Celsius degree. In this case, a quantization error, which is determined by a resolution of the measuring system, and the ohmmeter accuracy make the main contribution to the overall accuracy of measuring small temperature changes.

  5. Focusing of high power ultrasound beams and limiting values of shock wave parameters

    Science.gov (United States)

    Bessonova, O. V.; Khokhlova, V. A.; Bailey, M. R.; Canney, M. S.; Crum, L. A.

    2009-10-01

    In this work, the influence of nonlinear and diffraction effects on amplification factors of focused ultrasound systems is investigated. The limiting values of acoustic field parameters obtained by focusing of high power ultrasound are studied. The Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation was used for the numerical modeling. Solutions for the nonlinear acoustic field were obtained at output levels corresponding to both pre- and post-shock formation conditions in the focal area of the beam in a weakly dissipative medium. Numerical solutions were compared with experimental data as well as with known analytic predictions.

  6. Telemetry System of Biological Parameters

    Directory of Open Access Journals (Sweden)

    Jan Spisak

    2005-01-01

    Full Text Available The mobile telemetry system of biological parameters serves for reading and wireless data transfer of measured values of selected biological parameters to an outlying computer. It concerns basically long time monitoring of vital function of car pilot.The goal of this projects is to propose mobile telemetry system for reading, wireless transfer and processing of biological parameters of car pilot during physical and psychical stress. It has to be made with respect to minimal consumption, weight and maximal device mobility. This system has to eliminate signal noise, which is created by biological artifacts and disturbances during the data transfer.

  7. Ultrasonographic measurement of fetal growth parameters over three successive pregnancies in a captive Malayan tapir (Tapirus indicus).

    Science.gov (United States)

    Hoyer, M J; van Engeldorp Gastelaars, H M D

    2014-01-01

    This study was conducted to establish representative curves that allow evaluation of fetal growth and estimation of gestational age from measurement of fetal structures by ultrasound in Malayan tapirs (Tapirus indicus). Three pregnancies (i.e. 3 fetuses) were examined in one female Malayan tapir. Transabdominal ultrasonographic examination was performed without anesthesia from 79 ± 8 days to 281 ± 48 days (mean ± S.D.) post mating. To assess fetal growth attempts were made to measure biparietal diameter (BPD), head length (HL), thorax diameter A (TDA), thorax height A (THA), thorax diameter B (TDB), thorax height B (THB), abdomen diameter (AD), abdomen height (AH), humerus length (HUL) and Crown rump length (CRL). The value of each parameter as an estimator of gestational age was assessed by ease of observation and the length of time the parameter was measurable throughout gestation. The most precise predictors for gestational age in this study were BPD and CRL (weeks 10-20 of gestation), as well as AD and AH (weeks 14-43 of gestation). The parameters TDB, THB and HUL (weeks 15-41 of gestation) gave almost as good predictions. Fetal viability was assessed by identifying a fetal heartbeat and movement. All pregnancies resulted in normal deliveries and healthy offspring. The ultrasound examination was well tolerated by the female. The gestation lengths (399 ± 3 days) were within reported ranges. The serial transabdominal ultrasound, without the need for anesthesia, was an effective method to evaluate fetal growth, development and well being in a Malayan tapir. © 2014 Wiley Periodicals, Inc.

  8. Ion source plasma parameters measurement based on Langmuir probe with commercial frequency sweep

    International Nuclear Information System (INIS)

    Xie, Y.H.; Hu, C.D.; Liu, S.; Shong, S.H.; Jiang, C.C.; Liu, Z.M.

    2010-01-01

    Langmuir probe is one of the main diagnostic tools to measure the plasma parameters in the ion source. In this article, the commercial frequency power, which is sine wave of 50 Hz, was supplied on the Langmuir probe to measure the plasma parameters. The best feature of this probe sweep voltage is that it does not need extra design. The probe I-V characteristic curve can be got in less than 5 ms and the plasma parameters, the electron temperature and the electron density, varying with the time can be got in one plasma discharge of 400 ms.

  9. Measuring Nursing Value from the Electronic Health Record.

    Science.gov (United States)

    Welton, John M; Harper, Ellen M

    2016-01-01

    We report the findings of a big data nursing value expert group made up of 14 members of the nursing informatics, leadership, academic and research communities within the United States tasked with 1. Defining nursing value, 2. Developing a common data model and metrics for nursing care value, and 3. Developing nursing business intelligence tools using the nursing value data set. This work is a component of the Big Data and Nursing Knowledge Development conference series sponsored by the University Of Minnesota School Of Nursing. The panel met by conference calls for fourteen 1.5 hour sessions for a total of 21 total hours of interaction from August 2014 through May 2015. Primary deliverables from the bit data expert group were: development and publication of definitions and metrics for nursing value; construction of a common data model to extract key data from electronic health records; and measures of nursing costs and finance to provide a basis for developing nursing business intelligence and analysis systems.

  10. Measuring neutrino oscillation parameters using $\

    Energy Technology Data Exchange (ETDEWEB)

    Backhouse, Christopher James [Oriel College, Oxford (United Kingdom)

    2011-01-01

    MINOS is a long-baseline neutrino oscillation experiment. It consists of two large steel-scintillator tracking calorimeters. The near detector is situated at Fermilab, close to the production point of the NuMI muon-neutrino beam. The far detector is 735 km away, 716m underground in the Soudan mine, Northern Minnesota. The primary purpose of the MINOS experiment is to make precise measurements of the 'atmospheric' neutrino oscillation parameters (Δmatm2 and sin2atm). The oscillation signal consists of an energy-dependent deficit of vμ interactions in the far detector. The near detector is used to characterize the properties of the beam before oscillations develop. The two-detector design allows many potential sources of systematic error in the far detector to be mitigated by the near detector observations. This thesis describes the details of the vμ-disappearance analysis, and presents a new technique to estimate the hadronic energy of neutrino interactions. This estimator achieves a significant improvement in the energy resolution of the neutrino spectrum, and in the sensitivity of the neutrino oscillation fit. The systematic uncertainty on the hadronic energy scale was re-evaluated and found to be comparable to that of the energy estimator previously in use. The best-fit oscillation parameters of the vμ-disappearance analysis, incorporating this new estimator were: Δm2 = 2.32-0.08+0.12 x 10-3 eV2, sin 2 2θ > 0.90 (90% C.L.). A similar analysis, using data from a period of running where the NuMI beam was operated in a configuration producing a predominantly $\\bar{v}$μ beam, yielded somewhat different best-fit parameters Δ$\\bar{m}${sup 2} = (3.36-0.40+0.46(stat.) ± 0.06(syst.)) x 10-3eV2, sin2 2$\\bar{θ}$ = 0.86-0.12_0

  11. Direct quantum process tomography via measuring sequential weak values of incompatible observables.

    Science.gov (United States)

    Kim, Yosep; Kim, Yong-Su; Lee, Sang-Yun; Han, Sang-Wook; Moon, Sung; Kim, Yoon-Ho; Cho, Young-Wook

    2018-01-15

    The weak value concept has enabled fundamental studies of quantum measurement and, recently, found potential applications in quantum and classical metrology. However, most weak value experiments reported to date do not require quantum mechanical descriptions, as they only exploit the classical wave nature of the physical systems. In this work, we demonstrate measurement of the sequential weak value of two incompatible observables by making use of two-photon quantum interference so that the results can only be explained quantum physically. We then demonstrate that the sequential weak value measurement can be used to perform direct quantum process tomography of a qubit channel. Our work not only demonstrates the quantum nature of weak values but also presents potential new applications of weak values in analyzing quantum channels and operations.

  12. Estimation of the location parameter of distributions with known coefficient of variation by record values

    Directory of Open Access Journals (Sweden)

    N. K. Sajeevkumar

    2014-09-01

    Full Text Available In this article, we derived the Best Linear Unbiased Estimator (BLUE of the location parameter of certain distributions with known coefficient of variation by record values. Efficiency comparisons are also made on the proposed estimator with some of the usual estimators. Finally we give a real life data to explain the utility of results developed in this article.

  13. Perioperative versus postoperative measurement of Taylor Spatial Frame mounting parameters.

    Science.gov (United States)

    Sökücü, Sami; Demir, Bilal; Lapçin, Osman; Yavuz, Umut; Kabukçuoğlu, Yavuz S

    2014-01-01

    The aim of this study was to determine the differences, if any, between application parameters for the Taylor Spatial Frame (TSF) system obtained during surgery under fluoroscopy and after surgery from digital radiography. This retrospective study included 17 extremities of 15 patients (8 male, 7 female; mean age: 21.9 years, range: 10 to 55 years) who underwent TSF after deformity and fracture. Application parameters measured by fluoroscopy at the end of surgery after mounting the fixator were compared with parameters obtained from anteroposterior and lateral digital radiographs taken 1 day after surgery. Fixator was applied to the femur in 8 patients, tibia in 6 and radius in 3. Mean time to removal of the frame was 3.5 (range: 3 to 7) months. Mean perioperative anteroposterior, lateral and axial frame offsets of patients were 9.1 (range: 3 to 20) mm, 18.1 (range: 5 to 37) mm and 95.3 (range: 25 to 155) mm, respectively. Mean postoperative anteroposterior, lateral and axial frame offset radiographs were 11.8 (range: 2 to 30) mm, 18 (range: 6 to 47) mm and 109.5 (range: 28 to 195) mm, respectively. There was no statistically significant difference between the groups (p>0.05). While measurements taken during operation may lengthen the duration in the operation room, fluoroscopy may provide better images and is easier to perform than digital radiography. On the other hand, there is no difference between measurements taken during perioperative fluoroscopy and postoperative digital radiography.

  14. Measurement of the cp violation parameter sin 2 beta

    International Nuclear Information System (INIS)

    K.F. Kelley

    1999-01-01

    This thesis presents a measurement of the time-dependent asymmetry in the rate of (anti B) d 0 versus B d 0 decays to J/ψK s 0 . In the context of the Standard Model this is interpreted as a measurement of the CP violation parameter sin(2β). A total of 198±17 B d 0 /(anti B) d 0 decays were observed in p(anti p) collisions at √s=1.8 TeV by the CDF detector at the Fermilab Tevatron. The initial B flavor (whether B 0 or (anti B) 0 ) is determined by a same-side flavor tagging technique. The analysis results in sin(2β)=1.8±1.1(stat.)±0.3(syst.). This analysis demonstrates the feasibility of studying CP violation in the B 0 -(anti B) 0 system at a hadron collider. By applying the methods used in this analysis, future, higher-statistics experiments should be able to tightly constrain the parameters of the Standard Model

  15. Measurements of some parameters of thermal sparks with respect to their ability to ignite aviation fuel/air mixtures

    Science.gov (United States)

    Haigh, S. J.; Hardwick, C. J.; Baldwin, R. E.

    1991-01-01

    A method used to generate thermal sparks for experimental purposes and methods by which parameters of the sparks, such as speed, size, and temperature, were measured are described. Values are given of the range of such parameters within these spark showers. Titanium sparks were used almost exclusively, since it is particles of this metal which are found to be ejected during simulation tests to carbon fiber composite (CFC) joints. Tests were then carried out in which titanium sparks and spark showers were injected into JP4/(AVTAG F40) mixtures with air. Single large sparks and dense showers of small sparks were found to be capable of causing ignition. Tests were then repeated using ethylene/air mixtures, which were found to be more easily ignited by thermal sparks than the JP4/ air mixtures.

  16. Changes in the measurement of fair value : implications for accounting earnings.

    OpenAIRE

    Fargher, N.; Zhang, J.

    2014-01-01

    With the FASB's issue of staff position papers in 2009 and the relaxation of how fair value standards are applied, there has been a change in the practice of how fair value is measured. Since the FASB staff position papers in 2009, fair value measurement by financial institutions has increasingly relied on managerial assumptions. This study examines the impact of this change on the quality of earnings. Consistent with attribute substitution theory that emphasises reliability over relevance, w...

  17. Reliability of diabetic patients' gait parameters in a challenging environment.

    Science.gov (United States)

    Allet, L; Armand, S; de Bie, R A; Golay, A; Monnin, D; Aminian, K; de Bruin, E D

    2008-11-01

    Activities of daily life require us to move about in challenging environments and to walk on varied surfaces. Irregular terrain has been shown to influence gait parameters, especially in a population at risk for falling. A precise portable measurement system would permit objective gait analysis under such conditions. The aims of this study are to (a) investigate the reliability of gait parameters measured with the Physilog in diabetic patients walking on different surfaces (tar, grass, and stones); (b) identify the measurement error (precision); (c) identify the minimal clinical detectable change. 16 patients with Type 2 diabetes were measured twice within 8 days. After clinical examination patients walked, equipped with a Physilog, on the three aforementioned surfaces. ICC for each surface was excellent for within-visit analyses (>0.938). Inter-visit ICC's (0.753) were excellent except for the knee range parameter (>0.503). The coefficient of variation (CV) was lower than 5% for most of the parameters. Bland and Altman Plots, SEM and SDC showed precise values, distributed around zero for all surfaces. Good reliability of Physilog measurements on different surfaces suggests that Physilog could facilitate the study of diabetic patients' gait in conditions close to real-life situations. Gait parameters during complex locomotor activities (e.g. stair-climbing, curbs, slopes) have not yet been extensively investigated. Good reliability, small measurement error and values of minimal clinical detectable change recommend the utilization of Physilog for the evaluation of gait parameters in diabetic patients.

  18. Revisiting linear plasma waves for finite value of the plasma parameter

    Science.gov (United States)

    Grismayer, Thomas; Fahlen, Jay; Decyk, Viktor; Mori, Warren

    2010-11-01

    We investigate through theory and PIC simulations the Landau-damping of plasma waves with finite plasma parameter. We concentrate on the linear regime, γφB, where the waves are typically small and below the thermal noise. We simulate these condition using 1,2,3D electrostatic PIC codes (BEPS), noting that modern computers now allow us to simulate cases where (nλD^3 = [1e2;1e6]). We study these waves by using a subtraction technique in which two simulations are carried out. In the first, a small wave is initialized or driven, in the second no wave is excited. The results are subtracted to provide a clean signal that can be studied. As nλD^3 is decreased, the number of resonant electrons can be small for linear waves. We show how the damping changes as a result of having few resonant particles. We also find that for small nλD^3 fluctuations can cause the electrons to undergo collisions that eventually destroy the initial wave. A quantity of interest is the the life time of a particular mode which depends on the plasma parameter and the wave number. The life time is estimated and then compared with the numerical results. A surprising result is that even for large values of nλD^3 some non-Vlasov discreteness effects appear to be important.

  19. Theory of “Weak Value" and Quantum Mechanical Measurements

    OpenAIRE

    Shikano, Yutaka

    2012-01-01

    Comment: to be published from "Measurements in Quantum Mechanics", edited by M. R. Pahlavani (InTech, 2012) Chapter 4 page 75. Yutaka Shikano (2012). ISBN: 978-953-51-0058-4 Available from: http://www.intechopen.com/articles/show/title/theory-of-weak-value-and-quantum-mechanical-measurement

  20. Transfer parameter values in temperate forest ecosystems: a review

    International Nuclear Information System (INIS)

    Calmon, Philippe; Thiry, Yves; Zibold, Gregor; Rantavaara, Aino; Fesenko, Sergei

    2009-01-01

    Compared to agricultural lands, forests are complex ecosystems as they can involve diverse plant species associations, several vegetative strata (overstorey, shrubs, herbaceous and other annual plant layer) and multi-layered soil profiles (forest floor, hemi-organic and mineral layers). A high degree of variability is thus generally observed in radionuclide transfers and redistribution patterns in contaminated forests. In the long term, the soil compartment represents the major reservoir of radionuclides which can give rise to long-term plant and hence food contamination. For practical reasons, the contamination of various specific forest products has commonly been quantified using the aggregated transfer factor (T ag in m 2 kg -1 ) which integrates various environmental parameters including soil and plant type, root distribution as well as nature and vertical distribution of the deposits. Long lasting availability of some radionuclides was shown to be the source of much higher transfer in forest ecosystems than in agricultural lands. This study aimed at reviewing the most relevant quantitative information on radionuclide transfers to forest biota including trees, understorey vegetation, mushrooms, berries and game animals. For both radiocaesium and radiostrontium in trees, the order of magnitude of mean T ag values was 10 -3 m 2 kg -1 (dry weight). Tree foliage was usually 2-12 times more contaminated than trunk wood. Maximum contamination of tree components with radiocaesium was associated with (semi-)hydromorphic areas with thick humus layers. The transfer of radionuclides to mushrooms and berries is high, in comparison with foodstuffs grown in agricultural systems. Concerning caesium uptake by mushrooms, the transfer is characterized by a very large variability of T ag , from 10 -3 to 10 1 m 2 kg -1 (dry weight). For berries, typical values are around 0.01-0.1 m 2 kg -1 (dry weight). Transfer of radioactive caesium to game animals and reindeer and the rate of

  1. Transfer parameter values in temperate forest ecosystems: a review

    Energy Technology Data Exchange (ETDEWEB)

    Calmon, Philippe [Department of Radioecology, Institute of Radioprotection and Nuclear Safety, CE Cadarache, BP 3, 13115 Saint Paul-les-Durance Cedex (France)], E-mail: philippe.calmon@irsn.fr; Thiry, Yves [Biosphere Impact Studies, Belgian Nuclear Research Center (SCK.CEN, Foundation of Public Utility), 2400 Mol (Belgium); Zibold, Gregor [Hochschule Ravensburg-Weingarten, University of Applied Sciences, 88250 Weingarten (Germany); Rantavaara, Aino [Research and Environmental Surveillance, Radiation and Nuclear Safety Authority (STUK), BP 14, FIN-00881 Helsinki (Finland); Fesenko, Sergei [International Atomic Energy Agency (IAEA), 1400 Vienna (Austria)

    2009-09-15

    Compared to agricultural lands, forests are complex ecosystems as they can involve diverse plant species associations, several vegetative strata (overstorey, shrubs, herbaceous and other annual plant layer) and multi-layered soil profiles (forest floor, hemi-organic and mineral layers). A high degree of variability is thus generally observed in radionuclide transfers and redistribution patterns in contaminated forests. In the long term, the soil compartment represents the major reservoir of radionuclides which can give rise to long-term plant and hence food contamination. For practical reasons, the contamination of various specific forest products has commonly been quantified using the aggregated transfer factor (T{sub ag} in m{sup 2} kg{sup -1}) which integrates various environmental parameters including soil and plant type, root distribution as well as nature and vertical distribution of the deposits. Long lasting availability of some radionuclides was shown to be the source of much higher transfer in forest ecosystems than in agricultural lands. This study aimed at reviewing the most relevant quantitative information on radionuclide transfers to forest biota including trees, understorey vegetation, mushrooms, berries and game animals. For both radiocaesium and radiostrontium in trees, the order of magnitude of mean T{sub ag} values was 10{sup -3} m{sup 2} kg{sup -1} (dry weight). Tree foliage was usually 2-12 times more contaminated than trunk wood. Maximum contamination of tree components with radiocaesium was associated with (semi-)hydromorphic areas with thick humus layers. The transfer of radionuclides to mushrooms and berries is high, in comparison with foodstuffs grown in agricultural systems. Concerning caesium uptake by mushrooms, the transfer is characterized by a very large variability of T{sub ag}, from 10{sup -3} to 10{sup 1} m{sup 2} kg{sup -1} (dry weight). For berries, typical values are around 0.01-0.1 m{sup 2} kg{sup -1} (dry weight). Transfer

  2. Sensitivity of reactor integral parameters to #betta##betta# parameter of resolved resonances of fertile isotopes and to the α values, in thermal and epithermal spectra

    International Nuclear Information System (INIS)

    Barroso, D.E.G.

    1982-01-01

    A sensitivity analysis of reactor integral parameter to more 10% variation in the resolved resonance parameters #betta##betta# of the fertile isotope and the variations of more 10% in the α values (#betta# sub(#betta#)/#betta# sub(f)) of fissile isotopes of PWR fuel elements, is done. The analysis is made with thermal and epithermal spectra, those last generated in a fuel cell with low V sub(M)/V sub(F). The HAMMER system, the interface programs HELP and LITHE and the HAMMER computer codes, were used as a base for this study. (E.G.) [pt

  3. Transcutaneous oximetry measurements of the leg: comparing different measuring equipment and establishing values in healthy young adults.

    Science.gov (United States)

    Trinks, Tobias P; Blake, Denise F; Young, Derelle A; Thistlethwaite, Ken; Vangaveti, Venkat N

    2017-06-01

    Transcutaneous oximetry measurement (TCOM) is a non-invasive method of determining oxygen tension at the skin level using heated electrodes. To compare TCOM values generated by different machines and to establish lower limb TCOM values in a cohort of healthy individuals younger than 40 years of age. Sixteen healthy, non-smoking volunteers aged 18 to 39 years were recruited. TCOM was obtained at six locations on the lower leg and foot using three different Radiometer machines. Measurements were taken with subjects lying supine, breathing air. Except for one sensor site, there were no statistical differences in measurements obtained by the different TCOM machines. There was no statistical difference in measurements comparing left and right legs. Room air TCOM values for the different lower leg sites were (mean (SD) in mmHg): lateral leg 61.5 (9.2); lateral ankle 61.1 (9.7); medial ankle 59.1 (10.8); foot, first and second toe 63.4 (10.6); foot, fifth toe 59.9 (13.2) and plantar foot 74.1 (8.8). The overall mean TCOM value for the lower limb was 61 (10.8; 95% confidence intervals 60.05-62.0) mmHg. Lower-leg TCOM measurements using different Radiometer TCOM machines were comparable. Hypoxia has been defined as lower-leg TCOM values of less than 40 mmHg in non-diabetic patients and this is supported by our measurements. The majority (96.9%) of the lower leg TCOM values in healthy young adults are above the hypoxic threshold.

  4. Investigation on influence parameters in measurements of the optomechanical hole plate using an optical coordinate measuring machine

    DEFF Research Database (Denmark)

    Morace, Renate Erica; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2003-01-01

    This paper describes the results of an experimental investigation on influence parameters in optical coordinate measurements of the optomechanical hole plate. Special attention was paid to the background of the object, which strongly influences the measurement result. Furthermore, it is seen that...... influences, the measurements were all performed with no movements of the axes of the CMM....

  5. Lattice parameters values and phase diagram for the Cu2Zn1-zFezGeSe4 alloy system

    International Nuclear Information System (INIS)

    Caldera, D.; Quintero, M.; Morocoima, M.; Quintero, E.; Grima, P.; Marchan, N.; Moreno, E.; Bocaranda, P.; Delgado, G.E.; Mora, A.E.; Briceno, J.M.; Fernandez, J.L.

    2008-01-01

    X-ray powder diffraction and differential thermal analysis (DTA) measurements were made on polycrystalline samples of the Cu 2 Zn 1-z Fe z GeSe 4 alloy system. The diffraction patterns were used to show the equilibrium conditions and to estimate crystalline parameter values. It was found that, at room temperature, a single phase solid solution with the tetragonal stannite α structure (I4-bar2m) occurs across the whole composition range. The DTA thermograms were used to construct the phase diagram of the Cu 2 Zn 1-z Fe z GeSe 4 alloy system. It was confirmed that the Cu 2 ZnGeSe 4 compound melts incongruently. It was observed that undercooling effects occur for samples with z > 0.9

  6. Measurement of dosimetric parameters for Hi-ART helical tomotherapy unit

    International Nuclear Information System (INIS)

    Wang Yunlai; Sha Xiangyou; Dai Xiangkun; Ma Lin; Feng Linchun; Qu Baolin

    2008-01-01

    Objective: To develop a measurement method of dosimetric parameters for Hi-ART tomotherapy unit. Methods: Percentage depth doses and beam profiles were measured using the dedicated mini water phantom, and compared to the results of 6 MV X-ray from Primus accelerator. Following the AAPM TG51 protocol, absolute dose calibration was carried out under SSD of 8.5 cm at depth of 1.5 cm for field of 5 cm x 40 cm. The output linearity and reproducibility were evaluated. The output variation with the gantry rotation was also investigated using 0.6 cm 3 ion chamber in cylindrical perplex phantom and on-board MVCT detectors. Leaf fluence output factors were quantified for the leaf of interest and its adjacent leaves. Results: The buildup depth was around 1.0 cm. The PDD values at 10 cm for Hi-ART and Primus were 59.7% and 64.7%, respectively. Varying with the field width, the lateral and longitudinal beam profiles were not so homogeneous as the Primus fields. The measured dose rate was 848.38 cGy/min. The fitted linear function between the readings of dosimeter and the irradiated time was R(nC) =-0.017 + 0.256· t(sec), with a relative coefficient of 0.999. The maximum deviation and standard deviation of output were 1.6% and less than 0.5%; The maximum deviation and standard deviation of output changed by gantry angle were 1.1% and 0.5%, respectively. Leaf fluence output factors did not increase significantly when leaves were opened beyond the two adjacent leaves. Conclusions: Hi-ART Tomotherapy unit has a very high dose output and inhomogeneous beam profiles owing to its special design of the treatment head. This may be useful in dose calculation and treatment delivery. (authors)

  7. Test-retest reliability of spatial and temporal gait parameters in children with cerebral palsy as measured by an electronic walkway.

    Science.gov (United States)

    Sorsdahl, Anne Brit; Moe-Nilssen, Rolf; Strand, Liv Inger

    2008-01-01

    The purpose of this study was to examine test-retest reliability of seven selected temporal and spatial gait parameters and asymmetry measures in children with cerebral palsy. Seventeen children with CP between 3 and 13 years of age walked at three different speeds across an electronic walkway of 5.2m. The tests were repeated after approximately 25 min. The scores were normalized to a walking speed of 1.1m/s to avoid the confounding effect of gait speed on speed dependent gait parameters. Intraclass correlation coefficients (ICC(1,1) and ICC(3,1)) with 95% confidence intervals, within-subject standard deviation (S(w)) and smallest detectable difference (SDD) were calculated. The relative reliability of cadence, step length, stride length and single stance time was high to excellent (ICC(1,1) between 0.73 and 0.95), while it was poor for step width (ICC(1,1)=0.27 and 0.35). The relative reliability for two calculated asymmetry measures were high for the step length index (ICC(1,1)=0.82) and moderate for the single stance time index (ICC(1,1)=0.49). The absolute reliability values for all gait parameters are reported. Five of seven gait parameters measured by an electronic walkway and normalized to a common walking speed, appear to be highly repeatable in a short-term time span in children with CP who were able to walk without assistive walking devices, provided sufficient cognitive function.

  8. A Measurement of the Michel Parameters in Leptonic Decays of the Tau

    Energy Technology Data Exchange (ETDEWEB)

    Ammar, R.; Baringer, P.; Bean, A.; Besson, D.; Coppage, D.; Darling, C.; Davis, R.; Hancock, N.; Kotov, S.; Kravchenko, I.; Kwak, N. [University of Kansas, Lawrence, Kansas 66045 (United States); Anderson, S.; Kubota, Y.; Lattery, M.; ONeill, J.J.; Patton, S.; Poling, R.; Riehle, T.; Savinov, V.; Smith, A. [University of Minnesota, Minneapolis, Minnesota 55455 (United States); Alam, M.S.; Athar, S.B.; Ling, Z.; Mahmood, A.H.; Severini, H.; Timm, S.; Wappler, F. [State University of New York at Albany, Albany, New York 12222 (United States); Anastassov, A.; Blinov, S.; Duboscq, J.E.; Fujino, D.; Fulton, R.; Gan, K.K.; Hart, T.; Honscheid, K.; Kagan, H.; Kass, R.; Lee, J.; Spencer, M.B.; Sung, M.; Undrus, A.; Wanke, R.; Wolf, A.; Zoeller, M. [Ohio State University, Columbus, Ohio 43210 (United States); Nemati, B.; Richichi, S.J.; Ross, W.R.; Skubic, P.; Wood, M. [University of Oklahoma, Norman, Oklahoma 73019 (United States); Bishai, M.; Fast, J.; Gerndt, E.; Hinson, J.W.; Menon, N.; Miller, D.H.; Shibata, E.I.; Shipsey, I.P. [Purdue University, West Lafayette, Indiana 47907 (United States); Yurko, M.; Gibbons, L.; Johnson, S.D.; Kwon, Y.; Roberts, S.; Thorndike, E.H. [University of Rochester, Rochester, New York 14627 (United States); Jessop, C.P.; Lingel, K.; Marsiske, H.; Perl, M.L.; Schaffner, S.F.; Ugolini, D.; Wang, R.; Zhou, X. [Stanford Linear Accelerator Center, Stanford University, Stanford, California 94309 (United States); Coan, T.E.; Fadeyev, V.; Korolkov, I.; Maravin, Y.; Narsky, I.; Shelkov, V.; Staeck, J.; Stroynowski, R.; Volobouev, I.; Ye, J. [Southern Methodist University, Dallas, Texas 75275 (United States); Artuso, M.; Efimov, A.; Frasconi, F.; Gao, M.; Goldberg, M.; He, D.; Kopp, S.; Moneti, G.C.; Mountain, R.; Mukhin, Y.; Schuh, S.; Skwarnicki, T.; Stone, S.; Viehhauser, G.; Xing, X. [Syracuse University, Syracuse, New York 13244 (United States); Bartelt, J.; Csorna, S.E.; Jain, V.; and others

    1997-06-01

    We have measured the spectral shape Michel parameters {rho} and {eta} using leptonic decays of the {tau} , recorded by the CLEO II detector. Assuming e-{mu} universality in the vectorlike couplings, we find {rho}{sub e{mu}}=0.735{plus_minus}0.013{plus_minus}0.008 and {eta}{sub e{mu}}=-0.015{plus_minus}0.061{plus_minus}0.062 , where the first error is statistical and the second systematic. We also present measurements for the parameters for e and {mu} final states separately. {copyright} {ital 1997} {ital The American Physical Society}

  9. High grade intraepithelial neoplasia of prostate is associated with values of prostate specific antigen related parameters intermediate between prostate cancer and normal levels

    Directory of Open Access Journals (Sweden)

    Nermina Obralic

    2011-11-01

    Full Text Available High grade prostatic intraepithelial neoplasia (HGPIN is widely regarded as the precancerous. The aim of this study was to determine PSA related parameters in patients with initial PSA values 2-10 ng/mL and diagnosis of HGPIN without finding carcinoma at the time of their first needle biopsy. Study groups consisted of 100 men who were diagnosed HGPIN, 84 with cancer and 183 with benign hyperplasia on first biopsy of prostate. Total PSA and free PSA were measured and ratio free/total PSA and PSA density calculated. Mean values of these parameters were compared, and receiver operating characteristic curves were used for comparison of PSA related parameters to discriminate groups of patients. Total PSA, free PSA level and PSA density in patients with HGPIN (6.388 ng/mL did not differ significantly compared to prostate carcinoma (6.976 ng/mL or benign prostatic hyperplasia (6.07 ng/mL patients. Patients with HGPIN had significantly higher ratio free/total PSA than those with prostate carcinoma (0.168 vs 0.133, but significantly lower than patients with benign prostatic hyperplasia (0.168 vs 0.185. Ratio of free/total PSA significantly discriminate HGPIN from prostate carcinoma with sensitivity 84.52 and specify 45.00 at cut-off point of ≤ 0.18. Values of PSA, free PSA and ratio free/total PSA in cases of HGPIN appear to be intermediate between prostate cancer and normal levels. Ratio of free/total PSA may help in decision to repeat biopsies in the presence of HGPIN on biopsy, without concomitant prostate cancer, in patients suitable for curative treatment, with normal digito-rectal examination and trans-rectal sonography.

  10. Radon parameters in outdoor air

    International Nuclear Information System (INIS)

    Porstendoerfer, J.; Zock, Ch.; Wendt, J.; Reineking, A.

    2002-01-01

    For dose estimation by inhalation of the short lived radon progeny in outdoor air, the equilibrium factor (F), the unattached fraction (f p ), and the activity size distribution of the radon progeny were measured. Besides the radon parameter the meteorological parameter like temperature, wind speed, and rainfall intensity were registered. The measurements were carried out continuously for several weeks to find out the variation with time (day/night) and for different weather conditions. The radon gas, the unattached and aerosol-attached radon progenies were measured with an monitor developed for continuous measurements in outdoor air with low activity concentrations. For the determination of the activity size distribution a low pressure online alpha cascade impactor was used. The measured values of the equilibrium factor varied between 0.5-0.8 depending on weather conditions and time of the day. For high pressure weather conditions a diurnal variation of the F-factor was obtained. A lower average value (F=0.25) was registered during rainy days. The obtained f p -values varied between 0.04 and 0.12. They were higher than expected. The measured activity size distribution of the radon progeny averaged over a measurement period of three weeks can be approximated by a sum of three log-normal distributions. The greatest activity fraction is adsorbed on aerosol particles in the accumulation size range (100-1000 nm) with activity median diameters and geometric standard deviation values between 250-450 nm and 1.5-3.0, respectively. The activity median diameter of this accumulation mode in outdoor air was significantly greater than in indoor air (150-250 nm). An influence of the weather conditions on the activity of the accumulation particles was not significant. In contrast to the results of measurements in houses a small but significant fraction of the radon progeny (average value: 2%) is attached on coarse particles (>1000 nm). This fraction varied between 0-10%. 20

  11. Nuclide documentation. Element specific parameter values used in the biospheric models of the safety assessments SR 97 and SAFE

    International Nuclear Information System (INIS)

    Karlsson, Sara; Bergstroem, Ulla

    2002-05-01

    In this report the element and nuclide specific parameter values used in the biospheric models of the safety assessments SR 97 and SAFE are presented. The references used are presented and where necessary the process of estimation of data is described. The parameters treated in this report are distribution coefficients in soil, organic soil and suspended matter in freshwater and brackish water, root uptake factors for pasturage, cereals, root crops and vegetables, bioaccumulation factors for freshwater fish, brackish water fish, freshwater invertebrates and marine water plants, transfer coefficients for transfer to milk and meat, translocation factors and dose coefficients for external exposure, ingestion (age-dependent values) and inhalation (age-dependent values). The radionuclides treated are those which could be of interest in the two safety assessments. Physical data such as half-lives and type of decay are also presented

  12. Nuclide documentation. Element specific parameter values used in the biospheric models of the safety assessments SR 97 and SAFE

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, Sara; Bergstroem, Ulla [Studsvik Eco and Safety AB, Nykoeping (Sweden)

    2002-05-01

    In this report the element and nuclide specific parameter values used in the biospheric models of the safety assessments SR 97 and SAFE are presented. The references used are presented and where necessary the process of estimation of data is described. The parameters treated in this report are distribution coefficients in soil, organic soil and suspended matter in freshwater and brackish water, root uptake factors for pasturage, cereals, root crops and vegetables, bioaccumulation factors for freshwater fish, brackish water fish, freshwater invertebrates and marine water plants, transfer coefficients for transfer to milk and meat, translocation factors and dose coefficients for external exposure, ingestion (age-dependent values) and inhalation (age-dependent values). The radionuclides treated are those which could be of interest in the two safety assessments. Physical data such as half-lives and type of decay are also presented.

  13. Measuring and predicting Delta(vap)H298 values of ionic liquids.

    Science.gov (United States)

    Deyko, Alexey; Lovelock, Kevin R J; Corfield, Jo-Anne; Taylor, Alasdair W; Gooden, Peter N; Villar-Garcia, Ignacio J; Licence, Peter; Jones, Robert G; Krasovskiy, Vladimir G; Chernikova, Elena A; Kustov, Leonid M

    2009-10-14

    We report the enthalpies of vaporisation (measured using temperature programmed desorption by mass spectrometry) of twelve ionic liquids (ILs), covering four imidazolium, [C(m)C(n)Im]+, five pyrrolidinium, [C(n)C(m)Pyrr]+, two pyridinium, [C(n)Py]+, and a dication, [C3(C1Im)2]2+ based IL. These cations were paired with a range of anions: [BF4]-, [FeCl4]-, [N(CN)2]-, [PF3(C2F5)3]- ([FAP]-), [(CF3SO2)2N]- ([Tf2N]-) and [SCN]-. Using these results, plus those for a further eight imidazolium based ILs published earlier (which include the anions [CF3SO3]- ([TfO]-), [PF6]- and [EtSO4]-), we show that the enthalpies of vaporisation can be decomposed into three components. The first component is the Coulombic interaction between the ions, DeltaU(Cou,R), which is a function of the IL molar volume, V(m), and a parameter R(r) which quantifies the relative change in anion-cation distance on evaporation from the liquid phase to the ion pair in the gas phase. The second and third components are the van der Waals contributions from the anion, DeltaH(vdw,A), and the cation, DeltaH(vdw,C). We derive a universal value for R(r), and individual values of DeltaH(vdw,A) and DeltaH(vdw,C) for each of the anions and cations considered in this study. Given the molar volume, it is possible to estimate the enthalpies of vaporisation of ILs composed of any combination of the ions considered here; values for fourteen ILs which have not yet been studied experimentally are given.

  14. New measurements of W-values for protons and alpha particles

    International Nuclear Information System (INIS)

    Giesen, U.; Beck, J.

    2014-01-01

    The increasing importance of ion beams in cancer therapy and the lack of experimental data for W-values for protons and heavy ions in air require new measurements. A new experimental set-up was developed at PTB and consistent measurements of W-values in argon, nitrogen and air for protons and alpha particles with energies from 0.7 to 3.5 MeV u -1 at PTB, and for carbon ions between 3.6 and 7.0 MeV u -1 at GSI were carried out. This publication concentrates on the measurements with protons and alpha particles at PTB. The experimental methods and the determination of corrections for recombination effects, beam-induced background radiation and additional effects are presented. W-values in argon, nitrogen and air were measured for protons with energies of 1-3 MeV and for alpha particles with energies of 2.7-14 MeV. The energies of the primary particle beam were corrected for energy losses in the gold and Mylar foils, as well as for the kinematic energy loss due to scattering by 45 deg.. Beam-induced radiation backgrounds as well as recombination effects were determined and corrected for. The present results are summarised in Figure 2 for all three gases. The solid lines through the data points for each gas indicate an average W-value for that gas. The higher values for 2.7-MeV alpha particles agree with the trend in previous data towards lower energies. They are excluded from the averages. The relative standard uncertainties of the individual data points range from 1.3 to 3 %. The weighted averages over all energies are W(Ar) = 25.7 eV, W(N 2 ) = 35.6 eV and W(Air) = 34.2 eV. The averages serve as a first comparison and the lines on the plot are to guide the eye and are not meant to imply constant W-values for all energies and particles. The W-values for protons and alpha particles in argon and nitrogen have smaller uncertainties and are lower than the suggested values, but they are still in agreement within the uncertainties. For alpha particles with energies of 12

  15. Precision Measurement of Neutrino Oscillation Parameters with KamLAND

    Energy Technology Data Exchange (ETDEWEB)

    O' Donnell, Thomas [Univ. of California, Berkeley, CA (United States)

    2011-12-01

    This dissertation describes a measurement of the neutrino oscillation parameters m2 21, θ12 and constraints on θ13 based on a study of reactor antineutrinos at a baseline of ~ 180 km with the KamLAND detector. The data presented here was collected between April 2002 and November 2009, and amounts to a total exposure of 2.64 ± 0.07 × 1032 proton-years. For this exposure we expect 2140 ± 74(syst) antineutrino candidates from reactors, assuming standard model neutrino behavior, and 350±88(syst) candidates from background. The number observed is 1614. The ratio of background-subtracted candidates observed to expected is (NObs - NBkg)/ (NExp) = 0.59 ± 0.02(stat) ± 0.045(syst) which confirms reactor neutrino disappearance at greater than 5σ significance. Interpreting this deficit as being due to neutrino oscillation, the best-fit oscillation parameters from a three-flavor analysis are m2 21= 7.60+0.20 -0.19×10-5eV2, θ12 = 32.5 ± 2.9 degrees and sin2 θ13 = 0.025+0.035 -0.035, the 95% confidence-level upper limit on sin2 θ13 is sin2 θ13 < 0.083. Assuming CPT invariance, a combined analysis of KamLAND and solar neutrino data yields best-fit values: m2 21 = 7.60+0.20 -0.20 × 10-5eV2, θ12 = 33.5+1.0 -1.1 degrees, and sin2 θ13 = 0.013 ± 0.028 or sin2 θ13 < 0.06 at the 95% confidence level.

  16. Measurement of Water Quality Parameters for Before and After Maintenance Service in Water Filter System

    Directory of Open Access Journals (Sweden)

    Shaharudin Nuraida

    2017-01-01

    Full Text Available An adequate supply of safe drinking water is one of major ways to obtain healthy life. Water filter system is one way to improve the water quality. However, to maintain the performance of the system, it need to undergo the maintenance service. This study evaluate the requirement of maintenance service in water filter system. Water quality was measured before and after maintenance service. Parameters measured were pH, turbidity, residual chlorine, nitrate and heavy metals and these parameters were compared with National Drinking Water Quality Standards. Collection of data were involved three housing areas in Johor. The quality of drinking water from water filter system were analysed using pH meter, turbidity meter, DR6000 and Inductively Coupled Plasma-Mass Spectrometer. pH value was increased from 16.4% for before maintenance services to 30.7% for after maintenance service. Increment of removal percentage for turbidity, residual chlorine and nitrate after maintenance were 21.5, 13.6 and 26.7, respectively. This result shows that maintenance service enhance the performance of the system. However, less significant of maintenance service for enhance the removal of heavy metals which the increment of removal percentage in range 0.3 to 9.8. Only aluminium shows percentage removal for after maintenance with 92.8% lower compared to before maintenance service with 95.5%.

  17. Analytical method for determining breakdown slip of an induction motor based on of five parameters

    Directory of Open Access Journals (Sweden)

    Petrović Nenad

    2014-01-01

    Full Text Available The paper proposes an explicite formula for determining the critical slip value of an induction squirel cage motor based upon five parameters. Three of these parameters - rated slip, rated and breakdown torque are known by catalogue data. Two missing parameters are the arbitrary slip between the rated and critical slip value and the corresponding torque value. These two parameters are to be experimentaly obtained. The breakdown torque value given by catalogue data is usually less accurate than the rated torque value. The proposed formula gives the possibility of analysing the error distribution of the critical slip value obtained from catalogue and measured data in comparison with the values obtained from the mechanical characteristic based on the physical parameters of an induction motor.

  18. An automated A-value measurement tool for accurate cochlear duct length estimation.

    Science.gov (United States)

    Iyaniwura, John E; Elfarnawany, Mai; Ladak, Hanif M; Agrawal, Sumit K

    2018-01-22

    There has been renewed interest in the cochlear duct length (CDL) for preoperative cochlear implant electrode selection and postoperative generation of patient-specific frequency maps. The CDL can be estimated by measuring the A-value, which is defined as the length between the round window and the furthest point on the basal turn. Unfortunately, there is significant intra- and inter-observer variability when these measurements are made clinically. The objective of this study was to develop an automated A-value measurement algorithm to improve accuracy and eliminate observer variability. Clinical and micro-CT images of 20 cadaveric cochleae specimens were acquired. The micro-CT of one sample was chosen as the atlas, and A-value fiducials were placed onto that image. Image registration (rigid affine and non-rigid B-spline) was applied between the atlas and the 19 remaining clinical CT images. The registration transform was applied to the A-value fiducials, and the A-value was then automatically calculated for each specimen. High resolution micro-CT images of the same 19 specimens were used to measure the gold standard A-values for comparison against the manual and automated methods. The registration algorithm had excellent qualitative overlap between the atlas and target images. The automated method eliminated the observer variability and the systematic underestimation by experts. Manual measurement of the A-value on clinical CT had a mean error of 9.5 ± 4.3% compared to micro-CT, and this improved to an error of 2.7 ± 2.1% using the automated algorithm. Both the automated and manual methods correlated significantly with the gold standard micro-CT A-values (r = 0.70, p value measurement tool using atlas-based registration methods was successfully developed and validated. The automated method eliminated the observer variability and improved accuracy as compared to manual measurements by experts. This open-source tool has the potential to benefit

  19. Comparison for some measured and calculated nuclear Parameters ...

    African Journals Online (AJOL)

    The computed thermal neutron flux levels in the radial and axial direct-ions for different zones of the reactor compared favourably with measured values obtained from the zero power critical experiments. The trends of fast, slowing down, epithermal and thermal fluxes were also predicted. Journal of Applied Science and ...

  20. Linking Quality and Spending to Measure Value for People with Serious Illness

    Science.gov (United States)

    Rodgers, Phillip E.

    2018-01-01

    Abstract Background: Healthcare payment is rapidly evolving to reward value by measuring and paying for quality and spending performance. Rewarding value for the care of seriously ill patients presents unique challenges. Objective: To evaluate the state of current efforts to measure and reward value for the care of seriously ill patients. Design: We performed a PubMed search of articles related to (1) measures of spending for people with serious illness and (2) linking spending and quality measures and rewarding performance for the care of people with serious illness. We limited our search to U.S.-based studies published in English between January 1, 1960, and March 31, 2017. We supplemented this search by identifying public programs and other known initiatives that linked quality and spending for the seriously ill and extracted key program elements. Results: Our search related to linking spending and quality measures and rewarding performance for the care of people with serious illness yielded 277 articles. We identified three current public programs that currently link measures of quality and spending—or are likely to within the next few years—the Oncology Care Model; the Comprehensive End-Stage Renal Disease Model; and Home Health Value-Based Purchasing. Models that link quality and spending consist of four core components: (1) measuring quality, (2) measuring spending, (3) the payment adjustment model, and (4) the linking/incentive model. We found that current efforts to reward value for seriously ill patients are targeted for specific patient populations, do not broadly encourage the use of palliative care, and have not closely aligned quality and spending measures related to palliative care. Conclusions: We develop recommendations for policymakers and stakeholders about how measures of spending and quality can be balanced in value-based payment programs. PMID:29091529

  1. Parameters affecting level measurement interpretation of nuclear fuel solutions

    International Nuclear Information System (INIS)

    Hunt, B.A.; Landat, D.A.

    1999-01-01

    This paper describes a level measurement technique commonly used in the measurement of radioactive liquids and equipment utilised by the inspectors for safeguards purposes. Some of the influencing parameters affecting the measurement results by this technique are characterised. An essential requisite for successful process operations in chemical facilities involving liquids generally require some physical measurements to be made in-line for both process and quality control in order to achieve the necessary final product specifications . In nuclear fuel reprocessing facilities, the same objectives apply coupled however with an additional requirement of achieving nuclear material accountancy and control. In view of the strategic importance of some of the process vessels in nuclear facilities, accountancy has to be supported by volume and density measurements of low uncertainty. Inspectors therefore require instruments which are at the very least as good as or better than operator's equipment. The classical measurement technique and most widely applied for process liquids in nuclear installations is the bubbler probe or dip-tube technique. Here a regulated flow of air passes through tubes inserted to various depths into the vessel and pressure readings are measured which are a function of the presence of liquid height and density of solution in the tank. These readings, taken together with a pre-determined calibration curve are sufficient for the volume and amount of liquor in a tank to be quantified. All measurement equipment and instrumentation are long distances from the tank environment. The key physical parameter to measure at this location is therefore pressure. Equipment designed developed, commissioned and tested in the tank measurement facilities at Ispra and in nuclear installations in Europe, Japan and the USA, house digital pressure transducer modules with manufacture's declared features of better than 0.01% accuracy and long term stability of 0.01% full

  2. An Extreme-Value Approach to Anomaly Vulnerability Identification

    Science.gov (United States)

    Everett, Chris; Maggio, Gaspare; Groen, Frank

    2010-01-01

    The objective of this paper is to present a method for importance analysis in parametric probabilistic modeling where the result of interest is the identification of potential engineering vulnerabilities associated with postulated anomalies in system behavior. In the context of Accident Precursor Analysis (APA), under which this method has been developed, these vulnerabilities, designated as anomaly vulnerabilities, are conditions that produce high risk in the presence of anomalous system behavior. The method defines a parameter-specific Parameter Vulnerability Importance measure (PVI), which identifies anomaly risk-model parameter values that indicate the potential presence of anomaly vulnerabilities, and allows them to be prioritized for further investigation. This entails analyzing each uncertain risk-model parameter over its credible range of values to determine where it produces the maximum risk. A parameter that produces high system risk for a particular range of values suggests that the system is vulnerable to the modeled anomalous conditions, if indeed the true parameter value lies in that range. Thus, PVI analysis provides a means of identifying and prioritizing anomaly-related engineering issues that at the very least warrant improved understanding to reduce uncertainty, such that true vulnerabilities may be identified and proper corrective actions taken.

  3. Research on Joint Parameter Inversion for an Integrated Underground Displacement 3D Measuring Sensor

    Directory of Open Access Journals (Sweden)

    Nanying Shentu

    2015-04-01

    Full Text Available Underground displacement monitoring is a key means to monitor and evaluate geological disasters and geotechnical projects. There exist few practical instruments able to monitor subsurface horizontal and vertical displacements simultaneously due to monitoring invisibility and complexity. A novel underground displacement 3D measuring sensor had been proposed in our previous studies, and great efforts have been taken in the basic theoretical research of underground displacement sensing and measuring characteristics by virtue of modeling, simulation and experiments. This paper presents an innovative underground displacement joint inversion method by mixing a specific forward modeling approach with an approximate optimization inversion procedure. It can realize a joint inversion of underground horizontal displacement and vertical displacement for the proposed 3D sensor. Comparative studies have been conducted between the measured and inversed parameters of underground horizontal and vertical displacements under a variety of experimental and inverse conditions. The results showed that when experimentally measured horizontal displacements and vertical displacements are both varied within 0 ~ 30 mm, horizontal displacement and vertical displacement inversion discrepancies are generally less than 3 mm and 1 mm, respectively, under three kinds of simulated underground displacement monitoring circumstances. This implies that our proposed underground displacement joint inversion method is robust and efficient to predict the measuring values of underground horizontal and vertical displacements for the proposed sensor.

  4. Optimization of parameter values for complex pulse sequences by simulated annealing: application to 3D MP-RAGE imaging of the brain.

    Science.gov (United States)

    Epstein, F H; Mugler, J P; Brookeman, J R

    1994-02-01

    A number of pulse sequence techniques, including magnetization-prepared gradient echo (MP-GRE), segmented GRE, and hybrid RARE, employ a relatively large number of variable pulse sequence parameters and acquire the image data during a transient signal evolution. These sequences have recently been proposed and/or used for clinical applications in the brain, spine, liver, and coronary arteries. Thus, the need for a method of deriving optimal pulse sequence parameter values for this class of sequences now exists. Due to the complexity of these sequences, conventional optimization approaches, such as applying differential calculus to signal difference equations, are inadequate. We have developed a general framework for adapting the simulated annealing algorithm to pulse sequence parameter value optimization, and applied this framework to the specific case of optimizing the white matter-gray matter signal difference for a T1-weighted variable flip angle 3D MP-RAGE sequence. Using our algorithm, the values of 35 sequence parameters, including the magnetization-preparation RF pulse flip angle and delay time, 32 flip angles in the variable flip angle gradient-echo acquisition sequence, and the magnetization recovery time, were derived. Optimized 3D MP-RAGE achieved up to a 130% increase in white matter-gray matter signal difference compared with optimized 3D RF-spoiled FLASH with the same total acquisition time. The simulated annealing approach was effective at deriving optimal parameter values for a specific 3D MP-RAGE imaging objective, and may be useful for other imaging objectives and sequences in this general class.

  5. The Value of Improved Measurements in a Pig Slaughterhouse

    DEFF Research Database (Denmark)

    Kjærsgaard, Niels Christian

    The pig industry is an essential and important part of Danish economy with an export value in 2006 of more than DKK 28 billions [Danish Meat Association (2007)]. The competition is hard, and potential new competitors from low cost countries can be expected to enter the traditional Danish export...... markets. Therefore it is more important than ever to optimize all aspects of Danish pig production, slaughtering processes and delivery. This paper concerns the aspects of optimization at the slaughterhouses regarding estimation of the value of improved measurements. The slaughterhouse industry differs...... investments are expected to improve the quality of the measurements further. This paper concerns the use of Operations Research to solve a practical problem, which is of major importance for the industry, namely to improve the estimation of the economic effects of improved measurements. The benefit...

  6. Positive-operator-valued measure optimization of classical correlations

    NARCIS (Netherlands)

    Hamieh, S; Kobes, R; Zaraket, H

    We study the problem of optimization over positive-operator-valued measures to extract classical correlation in a bipartite quantum system. The proposed method is applied to binary states only. Moreover, to illustrate this method, an explicit example is studied in detail.

  7. On measurement of the acoustic nonlinearity parameter using the finite amplitude insertion substitution (FAIS) technique

    Science.gov (United States)

    Zeqiri, Bajram; Cook, Ashley; Rétat, Lise; Civale, John; ter Haar, Gail

    2015-04-01

    The acoustic nonlinearity parameter, B/A, is an important parameter which defines the way a propagating finite amplitude acoustic wave progressively distorts when travelling through any medium. One measurement technique used to determine its value is the finite amplitude insertion substitution (FAIS) method which has been applied to a range of liquid, tissue and tissue-like media. Importantly, in terms of the achievable measurement uncertainties, it is a relative technique. This paper presents a detailed study of the method, employing a number of novel features. The first of these is the use of a large area membrane hydrophone (30 mm aperture) which is used to record the plane-wave component of the acoustic field. This reduces the influence of diffraction on measurements, enabling studies to be carried out within the transducer near-field, with the interrogating transducer, test cell and detector positioned close to one another, an attribute which assists in controlling errors arising from nonlinear distortion in any intervening water path. The second feature is the development of a model which estimates the influence of finite-amplitude distortion as the acoustic wave travels from the rear surface of the test cell to the detector. It is demonstrated that this can lead to a significant systematic error in B/A measurement whose magnitude and direction depends on the acoustic property contrast between the test material and the water-filled equivalent cell. Good qualitative agreement between the model and experiment is reported. B/A measurements are reported undertaken at (20 ± 0.5) °C for two fluids commonly employed as reference materials within the technical literature: Corn Oil and Ethylene Glycol. Samples of an IEC standardised agar-based tissue-mimicking material were also measured. A systematic assessment of measurement uncertainties is presented giving expanded uncertainties in the range ±7% to ±14%, expressed at a confidence level close to 95

  8. Seasonal variation of meteorological factors on air parameters and ...

    African Journals Online (AJOL)

    The impacts of gas flaring on meteorological factors at Ibeno, Eket, Onna, Esit Eket and Umudike - Nigeria were investigated by measuring air quality parameters. The results show that the mean concentration of air parameters value were below Federal Environmental Protection Agency (FEPA) and United States ...

  9. Content dependent selection of image enhancement parameters for mobile displays

    Science.gov (United States)

    Lee, Yoon-Gyoo; Kang, Yoo-Jin; Kim, Han-Eol; Kim, Ka-Hee; Kim, Choon-Woo

    2011-01-01

    Mobile devices such as cellular phones and portable multimedia player with capability of playing terrestrial digital multimedia broadcasting (T-DMB) contents have been introduced into consumer market. In this paper, content dependent image quality enhancement method for sharpness and colorfulness and noise reduction is presented to improve perceived image quality on mobile displays. Human visual experiments are performed to analyze viewers' preference. Relationship between the objective measures and the optimal values of image control parameters are modeled by simple lookup tables based on the results of human visual experiments. Content dependent values of image control parameters are determined based on the calculated measures and predetermined lookup tables. Experimental results indicate that dynamic selection of image control parameters yields better image quality.

  10. Conjectures Regarding the Adoption of Fair Value Measurements in Brazil

    Directory of Open Access Journals (Sweden)

    Fernando Dal-Ri Murcia

    2008-01-01

    Full Text Available The issue of relevance versus reliability has always been a debate in accounting. Far from being a consensus among the community, the adoption of fair value measurements is intended to present a more realistic view of an entity¿s financial position. However, it could also cause a loss of credibility due to the subjectivity inherent in the valuation process. Wishing to make a contribution to the existing literature on this issue, this paper presents a discussion about the adoption of fair value measurements in Brazil. First, we present a brief examination of asset and liability valuation using the accounting theory as a framework. Following, we conduct a review of the International Accounting Standards Board (IASB and the Financial Accounting Standards Board (FASB standards regarding fair value measurements. Empirical studies addressing fair value are also reviewed. Finally, a discussion about its implementation is presented, aiming to take into account the specificities of the Brazilian Market. This paper intends to contribute to the construction of academic knowledge in accounting by debating an issue which is a real problem for organizations, and yet incipient in the national literature.

  11. Real-Time Aerodynamic Parameter Estimation without Air Flow Angle Measurements

    Science.gov (United States)

    Morelli, Eugene A.

    2010-01-01

    A technique for estimating aerodynamic parameters in real time from flight data without air flow angle measurements is described and demonstrated. The method is applied to simulated F-16 data, and to flight data from a subscale jet transport aircraft. Modeling results obtained with the new approach using flight data without air flow angle measurements were compared to modeling results computed conventionally using flight data that included air flow angle measurements. Comparisons demonstrated that the new technique can provide accurate aerodynamic modeling results without air flow angle measurements, which are often difficult and expensive to obtain. Implications for efficient flight testing and flight safety are discussed.

  12. Measuring, calculating and estimating PEP's parasitic mode loss parameters

    International Nuclear Information System (INIS)

    Weaver, J.N.

    1981-01-01

    This note discusses various ways the parasitic mode losses from a bunched beam to a vacuum chamber can be measured, calculated or estimated. A listing of the parameter, k, for the various PEP ring components is included. A number of formulas for calculating multiple and single pass losses are discussed and evaluated for several cases. 25 refs., 1 fig., 1 tab

  13. Commercial software upgrades may significantly alter Perfusion CT parameter values in colorectal cancer

    International Nuclear Information System (INIS)

    Goh, Vicky; Shastry, Manu; Endozo, Raymondo; Groves, Ashley M.; Engledow, Alec; Peck, Jacqui; Reston, Jonathan; Wellsted, David M.; Rodriguez-Justo, Manuel; Taylor, Stuart A.; Halligan, Steve

    2011-01-01

    To determine how commercial software platform upgrades impact on derived parameters for colorectal cancer. Following ethical approval, 30 patients with suspected colorectal cancer underwent Perfusion CT using integrated 64 detector PET/CT before surgery. Analysis was performed using software based on modified distributed parameter analysis (Perfusion software version 4; Perfusion 4.0), then repeated using the previous version (Perfusion software version 3; Perfusion 3.0). Tumour blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) were determined for identical regions-of-interest. Slice-by-slice and 'whole tumour' variance was assessed by Bland-Altman analysis. Mean BF, BV and PS was 20.4%, 59.5%, and 106% higher, and MTT 14.3% shorter for Perfusion 4.0 than Perfusion 3.0. The mean difference (95% limits of agreement) were +13.5 (-44.9 to 72.0), +2.61 (-0.06 to 5.28), -1.23 (-6.83 to 4.36), and +14.2 (-4.43 to 32.8) for BF, BV, MTT and PS respectively. Within subject coefficient of variation was 36.6%, 38.0%, 27.4% and 60.6% for BF, BV, MTT and PS respectively indicating moderate to poor agreement. Software version upgrades of the same software platform may result in significantly different parameter values, requiring adjustments for cross-version comparison. (orig.)

  14. A model for measuring value for money in professional sports

    Directory of Open Access Journals (Sweden)

    Vlad ROŞCA

    2013-07-01

    Full Text Available Few to almost none sports teams measure the entertainment value they provide to fans in exchange of the money the latter ones spend on admission fees. Scientific literature oversees the issue as well. The aim of this paper is to present a model that can be used for calculating value for money in the context of spectating sports. The research question asks how can value for money be conceptualized and measured for sports marketing purposes? Using financial and sporting variables, the method calculates how much money, on average, a fan had to spend for receiving quality entertainment – defined as won matches – from his favorite team, during the last season of the Romanian first division football championship. The results only partially confirm the research hypothesis, showing that not just price and sporting performances may influence the value delivered to fans, but other factors as well.

  15. Experimental Characterization of Ultra-Wideband Channel Parameter Measurements in an Underground Mine

    Directory of Open Access Journals (Sweden)

    B. Nkakanou

    2011-01-01

    Full Text Available Experimental results for an ultra-wideband (UWB channel parameters in an underground mining environment over a frequency range of 3 GHz to 10 GHz are reported. The measurements were taken both in LOS and NLOS cases in two different size mine galleries. In the NLOS case, results were acquired for different corridor obstruction angles. The results were obtained during an extensive measurement campaign in the UWB frequency, and the measurement procedure allows both the large- and small-scale parameters such as the path loss exponent, coherence bandwidth, and so forth, to be quantified. The capacity of the UWB channel as a function of the physical depth of the mine gallery has also been recorded for comparison purposes.

  16. Contrast-enhanced 3T MR Perfusion of Musculoskeletal Tumours: T1 Value Heterogeneity Assessment and Evaluation of the Influence of T1 Estimation Methods on Quantitative Parameters.

    Science.gov (United States)

    Gondim Teixeira, Pedro Augusto; Leplat, Christophe; Chen, Bailiang; De Verbizier, Jacques; Beaumont, Marine; Badr, Sammy; Cotten, Anne; Blum, Alain

    2017-12-01

    To evaluate intra-tumour and striated muscle T1 value heterogeneity and the influence of different methods of T1 estimation on the variability of quantitative perfusion parameters. Eighty-two patients with a histologically confirmed musculoskeletal tumour were prospectively included in this study and, with ethics committee approval, underwent contrast-enhanced MR perfusion and T1 mapping. T1 value variations in viable tumour areas and in normal-appearing striated muscle were assessed. In 20 cases, normal muscle perfusion parameters were calculated using three different methods: signal based and gadolinium concentration based on fixed and variable T1 values. Tumour and normal muscle T1 values were significantly different (p = 0.0008). T1 value heterogeneity was higher in tumours than in normal muscle (variation of 19.8% versus 13%). The T1 estimation method had a considerable influence on the variability of perfusion parameters. Fixed T1 values yielded higher coefficients of variation than variable T1 values (mean 109.6 ± 41.8% and 58.3 ± 14.1% respectively). Area under the curve was the least variable parameter (36%). T1 values in musculoskeletal tumours are significantly different and more heterogeneous than normal muscle. Patient-specific T1 estimation is needed for direct inter-patient comparison of perfusion parameters. • T1 value variation in musculoskeletal tumours is considerable. • T1 values in muscle and tumours are significantly different. • Patient-specific T1 estimation is needed for comparison of inter-patient perfusion parameters. • Technical variation is higher in permeability than semiquantitative perfusion parameters.

  17. Measurement of the Z boson resonance parameters

    International Nuclear Information System (INIS)

    Feldman, G.J.

    1989-11-01

    Using the Mark II detector at the SLC, we measure the Z mass and width to be 91.17 ± 0.18 GeV/c 2 and 1.95 +0. 40 -0.30 GeV, respectively. From a fit in which the visible Z width is constrained to its Standard Model value, the number of neutrino species is determined to be 3.0 ± or <4.4 at the 95% confidence level. 13 refs., 20 figs., 4 tabs

  18. Pre-Analytical Parameters Affecting Vascular Endothelial Growth Factor Measurement in Plasma: Identifying Confounders.

    Science.gov (United States)

    Walz, Johanna M; Boehringer, Daniel; Deissler, Heidrun L; Faerber, Lothar; Goepfert, Jens C; Heiduschka, Peter; Kleeberger, Susannah M; Klettner, Alexa; Krohne, Tim U; Schneiderhan-Marra, Nicole; Ziemssen, Focke; Stahl, Andreas

    2016-01-01

    Vascular endothelial growth factor-A (VEGF-A) is intensively investigated in various medical fields. However, comparing VEGF-A measurements is difficult because sample acquisition and pre-analytic procedures differ between studies. We therefore investigated which variables act as confounders of VEGF-A measurements. Following a standardized protocol, blood was taken at three clinical sites from six healthy participants (one male and one female participant at each center) twice one week apart. The following pre-analytical parameters were varied in order to analyze their impact on VEGF-A measurements: analyzing center, anticoagulant (EDTA vs. PECT / CTAD), cannula (butterfly vs. neonatal), type of centrifuge (swing-out vs. fixed-angle), time before and after centrifugation, filling level (completely filled vs. half-filled tubes) and analyzing method (ELISA vs. multiplex bead array). Additionally, intrapersonal variations over time and sex differences were explored. Statistical analysis was performed using a linear regression model. The following parameters were identified as statistically significant independent confounders of VEGF-A measurements: analyzing center, anticoagulant, centrifuge, analyzing method and sex of the proband. The following parameters were no significant confounders in our data set: intrapersonal variation over one week, cannula, time before and after centrifugation and filling level of collection tubes. VEGF-A measurement results can be affected significantly by the identified pre-analytical parameters. We recommend the use of CTAD anticoagulant, a standardized type of centrifuge and one central laboratory using the same analyzing method for all samples.

  19. Pre-Analytical Parameters Affecting Vascular Endothelial Growth Factor Measurement in Plasma: Identifying Confounders.

    Directory of Open Access Journals (Sweden)

    Johanna M Walz

    Full Text Available Vascular endothelial growth factor-A (VEGF-A is intensively investigated in various medical fields. However, comparing VEGF-A measurements is difficult because sample acquisition and pre-analytic procedures differ between studies. We therefore investigated which variables act as confounders of VEGF-A measurements.Following a standardized protocol, blood was taken at three clinical sites from six healthy participants (one male and one female participant at each center twice one week apart. The following pre-analytical parameters were varied in order to analyze their impact on VEGF-A measurements: analyzing center, anticoagulant (EDTA vs. PECT / CTAD, cannula (butterfly vs. neonatal, type of centrifuge (swing-out vs. fixed-angle, time before and after centrifugation, filling level (completely filled vs. half-filled tubes and analyzing method (ELISA vs. multiplex bead array. Additionally, intrapersonal variations over time and sex differences were explored. Statistical analysis was performed using a linear regression model.The following parameters were identified as statistically significant independent confounders of VEGF-A measurements: analyzing center, anticoagulant, centrifuge, analyzing method and sex of the proband. The following parameters were no significant confounders in our data set: intrapersonal variation over one week, cannula, time before and after centrifugation and filling level of collection tubes.VEGF-A measurement results can be affected significantly by the identified pre-analytical parameters. We recommend the use of CTAD anticoagulant, a standardized type of centrifuge and one central laboratory using the same analyzing method for all samples.

  20. Geotechnical Parameters from Seismic Measurements: Two Field Examples from Egypt and Saudi Arabia

    KAUST Repository

    Khalil, Mohamed H.

    2016-03-18

    © 2016 EEGS. Geotechnical parameters were used to determine subsurface rock quality for construction purposes. We summarize the mathematical relationships used to calculate the geotechnical parameters from P- and S-wave velocities and density values. These relationships are applied to two field examples; the first is a regional seismic study in Egypt and the second is a 2-D seismic profile recorded in Saudi Arabia. Results from both field examples are used to determine the subsurface rock quality and locate zones that should be avoided during construction. We suggest combining all geotechnical parameters into one map using a normalized-weighted relation, which helps to locate the zones with high versus low rock quality for engineering purposes.

  1. Fast determination of plasma parameters through function parametrization

    International Nuclear Information System (INIS)

    Braams, B.J.; Jilge, W.; Lackner, K.

    1985-09-01

    The method of function parametrization, developed by H. Wind for fast data evaluation in high energy physics, is demonstrated in the context of controlled fusion research. This method relies on a statistical analysis of a large data base of simulated experiments in order to obtain a functional representation for intrinsic physical parameters of a system in terms of the values of the measurements. Rapid determination of characteristic equilibrium parameters of a tokamak discharge is shown to be a particularly indicated application. The method is employed on the ASDEX experiment to determine the following parameters of the plasma: position of the magnetic axis, geometric center, and current center; minor radius, elongation, and area of the plasma column; a normalized safety factor at the plasma boundary; the Shafranov parameter βsub(p)+lsub(i)/2; the flux difference between the plasma boundary and an external reference value; the position of the lower and upper saddle points, and the intersections of the separatrix with the four divertor plates. The relevant measurements consist of three differential poloidal flux measurements, four poloidal field measurements, the current through the multipole shaping coils, and the total plasma current. Function parametrization supplies a very accurate interpretation of these data, which is now used for online data analysis, and is also sufficiently fast to be suitable for real-time control of the plasma. (orig.)

  2. Measuring the electron-ion ring parameters by bremsstrahlung

    International Nuclear Information System (INIS)

    Inkin, V.D.; Mozelev, A.A.; Sarantsev, V.P.

    1982-01-01

    A system is described for measuring the number of electrons and ions in the electron-ion rings of a collective heavy ion accelerator. The system operation is based on detecting gamma quanta of bremsstrahlung following the ring electron interaction with the nuclei of neutral atoms and ions at different stages of filling the ring with ions. The radiation detector is a scintillation block - a photomultiplier operating for counting with NaI(Tl) crystal sized 30x30 mm and ensuring the detection efficiency close to unity. The system apparatus is made in the CAMAC standard and rems on-line with the TRA/i miniature computer. The block-diagrams of the system and algorithm of data processing are presented. A conclusion is drawn that the results of measuring the ring parameters with the use of the diagnostics system described are in good agreement within the range of measuring errors with those obtained by means of the diagnostics system employing synchrotron radiation and induction sensors

  3. Measurement invariance of the Portrait Values Questionnaire across 25 European countries

    DEFF Research Database (Denmark)

    Scholderer, Joachim

    The Portrait Values Questionnaire (PVQ) is tested for cross-cultural validity. Measurement characteristics are compared across representative consumer samples from 25 European countries (total N = 37,592) using multi-group confirmatory factor analysis with structured means. The results suggest....... Hence, most direct comparisons of PVQ raw scores and sample statistics between European countries are valid without correction. Furthermore, it can be concluded that the ten values measured by the PVQ are invariant across European countries in terms of their relative position on the quasi......-circumplex hypothesised by the theory of basic human values....

  4. Parameters-adjustable front-end controller in digital nuclear measurement system

    International Nuclear Information System (INIS)

    Hao Dejian; Zhang Ruanyu; Yan Yangyang; Wang Peng; Tang Changjian

    2013-01-01

    Background: One digitizer is used to implement a digital nuclear measurement for the acquisition of nuclear information. Purpose: A principle and method of a parameter-adjustable front-end controller is presented for the sake of reducing the quantitative errors while getting the maximum ENOB (effective number of bits) of ADC (analog-to-digital converter) during waveform digitizing, as well as reducing the losing counts. Methods: First of all, the quantitative relationship among the radiation count rate (n), the amplitude of input signal (V in ), the conversion scale of ADC (±V) and the amplification factor (A) was derived. Secondly, the hardware and software of the front-end controller were designed to fulfill matching the output of different detectors, adjusting the amplification linearly through the control of channel switching, and setting of digital potentiometer by CPLD (Complex Programmable Logic Device). Results: (1) Through the measurement of γ-ray of Am-241 under our digital nuclear measurement set-up with CZT detector, it was validated that the amplitude of output signal of detectors of RC feedback type could be amplified linearly with adjustable amplification by the front-end controller. (2) Through the measurement of X-ray spectrum of Fe-5.5 under our digital nuclear measurement set-up with Si-PIN detector, it was validated that the front-end controller was suitable for the switch resetting type detectors, by which high precision measurement under various count rates could be fulfilled. Conclusion: The principle and method of the parameter-adjustable front-end controller presented in this paper is correct and feasible. (authors)

  5. Expectation values of local fields for a two-parameter family of integrable models and related perturbed conformal field theories

    International Nuclear Information System (INIS)

    Baseilhac, P.; Fateev, V.A.

    1998-01-01

    We calculate the vacuum expectation values of local fields for the two-parameter family of integrable field theories introduced and studied by Fateev (1996). Using this result we propose an explicit expression for the vacuum expectation values of local operators in parafermionic sine-Gordon models and in integrable perturbed SU(2) coset conformal field theories. (orig.)

  6. The Use of Asymptotic Functions for Determining Empirical Values of CN Parameter in Selected Catchments of Variable Land Cover

    Directory of Open Access Journals (Sweden)

    Wałęga Andrzej

    2017-12-01

    Full Text Available The aim of the study was to assess the applicability of asymptotic functions for determining the value of CN parameter as a function of precipitation depth in mountain and upland catchments. The analyses were carried out in two catchments: the Rudawa, left tributary of the Vistula, and the Kamienica, right tributary of the Dunajec. The input material included data on precipitation and flows for a multi-year period 1980–2012, obtained from IMGW PIB in Warsaw. Two models were used to determine empirical values of CNobs parameter as a function of precipitation depth: standard Hawkins model and 2-CN model allowing for a heterogeneous nature of a catchment area.

  7. Measurement of speech parameters in casual speech of dementia patients

    NARCIS (Netherlands)

    Ossewaarde, Roelant; Jonkers, Roel; Jalvingh, Fedor; Bastiaanse, Yvonne

    Measurement of speech parameters in casual speech of dementia patients Roelant Adriaan Ossewaarde1,2, Roel Jonkers1, Fedor Jalvingh1,3, Roelien Bastiaanse1 1CLCG, University of Groningen (NL); 2HU University of Applied Sciences Utrecht (NL); 33St. Marienhospital - Vechta, Geriatric Clinic Vechta

  8. Local measurement of transport parameters for laser injected trace impurities

    Energy Technology Data Exchange (ETDEWEB)

    Giannella, R; Lauro-Taroni, L [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking

    1994-07-01

    A procedure has been developed that determines local measurements of transport parameters`s profiles for injected impurities. The measured profiles extend from the plasma centre up to a certain radial position (usually {rho} = 0.6-0.7). In the outer region of the plasma the procedure supplies ``most suitable extensions`` up to the plasma edge of the measured transport profiles. The procedure intrinsically assures consistency and excellent agreement between the simulated and experimental data of local broad band soft X-ray emissivity and intensities of individual emission lines from different ion states of the injected impurities. 4 refs., 3 figs.

  9. Option's value - Greek measures fluctuations and their consequences

    Directory of Open Access Journals (Sweden)

    Izabela Pruchnicka-Grabias

    2004-01-01

    Full Text Available Options are financial instruments that can be applied in many situations. Options buyers sell risk which is bought by their sellers who are obliged to reduce it as much as possible. It can be done by using hedging strategies based on Greek letters and options values analysis. The author proves that Greek letters are not constant during the time of option’s life. The paper shows to what extent they are influenced by such factors as risk free interest rate, volatility, underlying asset price and time to maturity. The conclusion is that options sellers must play an active role, i.e. follow fluctuations of all these parameters and modify their hedging portfolios regularly.

  10. The Association between Parameters of Malnutrition and Diagnostic Measures of Sarcopenia in Geriatric Outpatients

    Science.gov (United States)

    Reijnierse, Esmee M.; Trappenburg, Marijke C.; Leter, Morena J.; Blauw, Gerard Jan; de van der Schueren, Marian A. E.; Meskers, Carel G. M.; Maier, Andrea B.

    2015-01-01

    Objectives Diagnostic criteria for sarcopenia include measures of muscle mass, muscle strength and physical performance. Consensus on the definition of sarcopenia has not been reached yet. To improve insight into the most clinically valid definition of sarcopenia, this study aimed to compare the association between parameters of malnutrition, as a risk factor in sarcopenia, and diagnostic measures of sarcopenia in geriatric outpatients. Material and Methods This study is based on data from a cross-sectional study conducted in a geriatric outpatient clinic including 185 geriatric outpatients (mean age 82 years). Parameters of malnutrition included risk of malnutrition (assessed by the Short Nutritional Assessment Questionnaire), loss of appetite, unintentional weight loss and underweight (body mass index malnutrition (independent variables) and diagnostic measures of sarcopenia (dependent variables) were analysed using multivariate linear regression models adjusted for age, body mass, fat mass and height in separate models. Results None of the parameters of malnutrition was consistently associated with diagnostic measures of sarcopenia. The strongest associations were found for both relative and absolute muscle mass; less stronger associations were found for muscle strength and physical performance. Underweight (p = malnutrition relate differently to diagnostic measures of sarcopenia in geriatric outpatients. The association between parameters of malnutrition and diagnostic measures of sarcopenia was strongest for both relative and absolute muscle mass, while less strong associations were found with muscle strength and physical performance. PMID:26284368

  11. Using Indirect Turbulence Measurements for Real-Time Parameter Estimation in Turbulent Air

    Science.gov (United States)

    Martos, Borja; Morelli, Eugene A.

    2012-01-01

    The use of indirect turbulence measurements for real-time estimation of parameters in a linear longitudinal dynamics model in atmospheric turbulence was studied. It is shown that measuring the atmospheric turbulence makes it possible to treat the turbulence as a measured explanatory variable in the parameter estimation problem. Commercial off-the-shelf sensors were researched and evaluated, then compared to air data booms. Sources of colored noise in the explanatory variables resulting from typical turbulence measurement techniques were identified and studied. A major source of colored noise in the explanatory variables was identified as frequency dependent upwash and time delay. The resulting upwash and time delay corrections were analyzed and compared to previous time shift dynamic modeling research. Simulation data as well as flight test data in atmospheric turbulence were used to verify the time delay behavior. Recommendations are given for follow on flight research and instrumentation.

  12. Physical characteristics and resistance parameters of typical urban cyclists.

    Science.gov (United States)

    Tengattini, Simone; Bigazzi, Alexander York

    2018-03-30

    This study investigates the rolling and drag resistance parameters and bicycle and cargo masses of typical urban cyclists. These factors are important for modelling of cyclist speed, power and energy expenditure, with applications including exercise performance, health and safety assessments and transportation network analysis. However, representative values for diverse urban travellers have not been established. Resistance parameters were measured utilizing a field coast-down test for 557 intercepted cyclists in Vancouver, Canada. Masses were also measured, along with other bicycle attributes such as tire pressure and size. The average (standard deviation) of coefficient of rolling resistance, effective frontal area, bicycle plus cargo mass, and bicycle-only mass were 0.0077 (0.0036), 0.559 (0.170) m 2 , 18.3 (4.1) kg, and 13.7 (3.3) kg, respectively. The range of measured values is wider and higher than suggested in existing literature, which focusses on sport cyclists. Significant correlations are identified between resistance parameters and rider and bicycle attributes, indicating higher resistance parameters for less sport-oriented cyclists. The findings of this study are important for appropriately characterising the full range of urban cyclists, including commuters and casual riders.

  13. The prognostic value of cortical magnetic stimulation in acute middle cerebral artery infarction compared to other parameters

    NARCIS (Netherlands)

    Timmerhuis, Th.P.J.; Hageman, G.; Oosterloo, Sebe J.; Rozeboom, A.R.

    1996-01-01

    The prognostic value of magnetic evoked potentials (MEP), somatosensory evoked potentials (SSEP), age and radiological parameters was determined in 50 patients with acute middle cerebral artery infarction. We performed MEP and SSEP within 4 days and after 6 weeks and 3 months of the infarction and

  14. Critical laboratory values in hemostasis: toward consensus.

    Science.gov (United States)

    Lippi, Giuseppe; Adcock, Dorothy; Simundic, Ana-Maria; Tripodi, Armando; Favaloro, Emmanuel J

    2017-09-01

    The term "critical values" can be defined to entail laboratory test results that significantly lie outside the normal (reference) range and necessitate immediate reporting to safeguard patient health, as well as those displaying a highly and clinically significant variation compared to previous data. The identification and effective communication of "highly pathological" values has engaged the minds of many clinicians, health care and laboratory professionals for decades, since these activities are vital to good laboratory practice. This is especially true in hemostasis, where a timely and efficient communication of critical values strongly impacts patient management. Due to the heterogeneity of available data, this paper is hence aimed to analyze the state of the art and provide an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis, thus providing a basic document for future consultation that assists laboratory professionals and clinicians alike. KEY MESSAGES Critical values are laboratory test results significantly lying outside the normal (reference) range and necessitating immediate reporting to safeguard patient health. A broad heterogeneity exists about critical values in hemostasis worldwide. We provide here an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis.

  15. Measuring Children's Environmental Attitudes and Values in Northwest Mexico: Validating a Modified Version of Measures to Test the Model of Ecological Values (2-MEV)

    Science.gov (United States)

    Schneller, A. J.; Johnson, B.; Bogner, F. X.

    2015-01-01

    This paper describes the validation process of measuring children's attitudes and values toward the environment within a Mexican sample. We applied the Model of Ecological Values (2-MEV), which has been shown to be valid and reliable in 20 countries, including one Spanish speaking culture. Items were initially modified to fit the regional dialect,…

  16. Applicability of International and DOE Target Values to ALD Destructive Measurement Applications

    International Nuclear Information System (INIS)

    Holland, M.K.

    2002-01-01

    International Target values and target value applicability are a function of the nuclear material processing campaign or application for which the accountability measurement method is being applied. Safeguarding significant quantities of nuclear-grade materials requires that accountability measurements be as accurate, precise, and representative as practically possible. In general, the ITV provides a benchmark for determining generic acceptability of the performance of the various accountability measurement methods, since it represents a performance level that is accepted as highly reliable. There are cases where it is acceptable to select alternative accountability methods not specifically referenced by the ITV, or to use the recognized measurement method, even though the uncertainties are greater than the target values

  17. Correlation and agreement of a digital and conventional method to measure arch parameters.

    Science.gov (United States)

    Nawi, Nes; Mohamed, Alizae Marny; Marizan Nor, Murshida; Ashar, Nor Atika

    2018-01-01

    The aim of the present study was to determine the overall reliability and validity of arch parameters measured digitally compared to conventional measurement. A sample of 111 plaster study models of Down syndrome (DS) patients were digitized using a blue light three-dimensional (3D) scanner. Digital and manual measurements of defined parameters were performed using Geomagic analysis software (Geomagic Studio 2014 software, 3D Systems, Rock Hill, SC, USA) on digital models and with a digital calliper (Tuten, Germany) on plaster study models. Both measurements were repeated twice to validate the intraexaminer reliability based on intraclass correlation coefficients (ICCs) using the independent t test and Pearson's correlation, respectively. The Bland-Altman method of analysis was used to evaluate the agreement of the measurement between the digital and plaster models. No statistically significant differences (p > 0.05) were found between the manual and digital methods when measuring the arch width, arch length, and space analysis. In addition, all parameters showed a significant correlation coefficient (r ≥ 0.972; p digital and manual measurements. Furthermore, a positive agreement between digital and manual measurements of the arch width (90-96%), arch length and space analysis (95-99%) were also distinguished using the Bland-Altman method. These results demonstrate that 3D blue light scanning and measurement software are able to precisely produce 3D digital model and measure arch width, arch length, and space analysis. The 3D digital model is valid to be used in various clinical applications.

  18. The Research of Screw Thread Parameter Measurement Based on Position Sensitive Detector and Laser

    International Nuclear Information System (INIS)

    Tong, Q B; Ding, Z L; Chen, J C; Ai, L L; Yuan, F

    2006-01-01

    A technique and system of measuring screw thread parameter based on the theory of laser measurement is presented in this paper, which can be carried out the automated measurement of screw thread parameter. An inspection instrument was designed and produced, which included exterior imaging system of optical path, transverse displacement measurement system, axial displacement measurement system, and a module to deal with, control and assess the data in the upper system. The inspection and estimate of the screw thread contour curve were completed by using position sensitive device (PSD) as photoelectric detector to measure the coordinate data of the screw thread contour curve in the transverse section, and using precise raster to measure the axial displacement of the precision worktable under the screw thread test criterion., computer can gives a measured result according to coordinate data of the screw thread obtained by PSD. The relation between measured spot and image is established, and optimum design of the system organization are introduced, including the image length of receiving lens focal length optical system and the choice of PSD , and some main factor affected measuring precision are analyzed. The experimental results show that the measurement uncertainty of screw thread minor diameter can reach 0. 5μm, which can meet most requests for the measurement of screw thread parameter

  19. Synopses/physical significance of complex-valued catalyst parameters in heterogeneous catalysis

    Energy Technology Data Exchange (ETDEWEB)

    Hesse, D

    1979-08-01

    An independent parameter was used to describe the local values of the interdependent thermodynamic variables of the coupled effects of transfer, sorption, and surface reaction at steady state in a packed bed of porous catalyst. A system reduction yielded a generalized concept of the pore effectiveness factor, H, which was unity or a real or imaginary complex number when the coupled diffusion and reaction processes do not affect, inhibit, or enhance conversion, respectively. These concepts are illustrated by ethylene hydrogenation on platinum, a process in which ethylene adsorbs much more strongly than hydrogen, but diffuses more slowly; as the rate is proportional to the product of hydrogen and ethylene surface coverage and the more strongly adsorbed ethylene occupies the majority of the available sites, a decrease in gas-phase ethylene concentration would increase the conversion rate. The reaction rate also increases with decreasing distance from the catalyst particle core.

  20. Winter blood values of selected parameters in a group of non-hibernating captive brown bears (Ursus arctos).

    Science.gov (United States)

    Sergiel, A; Bednarski, M; Maślak, R; Piasecki, T; Huber, D

    2015-01-01

    Bears undergo some significant changes reflected in blood values during winter season. The most significant are reduced urea and increased creatinine, by some authors considered to be physiological indicators of hibernation. Studied group of six captive brown bears (Ursus arctos) showed decreased activity in winter but were accepting food and walked outdoors. Blood parameters assessed in February 2011 revealed mean values of leucocytes and neutrophils as significantly lower, and creatinine significantly increased compared to captive and free living bears sampled during other seasons when bears are active.

  1. The bottomside parameters B0, B1 obtained from incoherent scatter measurements during a solar maximum and their comparisons with the IRI-2001 model

    Directory of Open Access Journals (Sweden)

    N. K. Sethi

    2002-06-01

    Full Text Available High resolution electron density profiles (Ne measured with the Arecibo (18.4 N, 66.7 W, Incoherent Scatter radar (I. S. are used to obtain the bottomside shape parameters B0, B1 for a solar maximum period (1989–90. Median values of these parameters are compared with those obtained from the IRI-2001 model. It is observed that during summer, the IRI values agree fairly well with the Arecibo values, though the numbers are somewhat larger during the daytime. Discrepancies occur during winter and equinox, when the IRI underestimates B0 for the local times from about 12:00 LT to about 20:00 LT. Furthermore, the IRI model tends to generally overestimate B1 at all local times. At Arecibo, B0 increases by about 50%, and B1 decreases by about 30% from solar minimum to solar maximum.Key words. Ionosphere (equational ionosphere; modeling and forecasting

  2. Finite element approximation for time-dependent diffusion with measure-valued source

    Czech Academy of Sciences Publication Activity Database

    Seidman, T.; Gobbert, M.; Trott, D.; Kružík, Martin

    2012-01-01

    Roč. 122, č. 4 (2012), s. 709-723 ISSN 0029-599X R&D Projects: GA AV ČR IAA100750802 Institutional support: RVO:67985556 Keywords : measure-valued source * diffusion equation Subject RIV: BA - General Mathematics Impact factor: 1.329, year: 2012 http://library.utia.cas.cz/separaty/2012/MTR/kruzik-finite element approximation for time - dependent diffusion with measure-valued source.pdf

  3. CO2 uptake and ecophysiological parameters of the grain crops of midcontinent North America: estimates from flux tower measurements

    Science.gov (United States)

    Gilmanov, Tagir; Wylie, Bruce; Tieszen, Larry; Meyers, Tilden P.; Baron, Vern S.; Bernacchi, Carl J.; Billesbach, David P.; Burba, George G.; Fischer, Marc L.; Glenn, Aaron J.; Hanan, Niall P.; Hatfield, Jerry L.; Heuer, Mark W.; Hollinger, Steven E.; Howard, Daniel M.; Matamala, Roser; Prueger, John H.; Tenuta, Mario; Young, David G.

    2013-01-01

    We analyzed net CO2 exchange data from 13 flux tower sites with 27 site-years of measurements over maize and wheat fields across midcontinent North America. A numerically robust “light-soil temperature-VPD”-based method was used to partition the data into photosynthetic assimilation and ecosystem respiration components. Year-round ecosystem-scale ecophysiological parameters of apparent quantum yield, photosynthetic capacity, convexity of the light response, respiration rate parameters, ecological light-use efficiency, and the curvature of the VPD-response of photosynthesis for maize and wheat crops were numerically identified and interpolated/extrapolated. This allowed us to gap-fill CO2 exchange components and calculate annual totals and budgets. VPD-limitation of photosynthesis was systematically observed in grain crops of the region (occurring from 20 to 120 days during the growing season, depending on site and year), determined by the VPD regime and the numerical value of the curvature parameter of the photosynthesis-VPD-response, σVPD. In 78% of the 27 site-years of observations, annual gross photosynthesis in these crops significantly exceeded ecosystem respiration, resulting in a net ecosystem production of up to 2100 g CO2 m−2 year−1. The measurement-based photosynthesis, respiration, and net ecosystem production data, as well as the estimates of the ecophysiological parameters, provide an empirical basis for parameterization and validation of mechanistic models of grain crop production in this economically and ecologically important region of North America.

  4. Hydrological model parameter dimensionality is a weak measure of prediction uncertainty

    Science.gov (United States)

    Pande, S.; Arkesteijn, L.; Savenije, H.; Bastidas, L. A.

    2015-04-01

    This paper shows that instability of hydrological system representation in response to different pieces of information and associated prediction uncertainty is a function of model complexity. After demonstrating the connection between unstable model representation and model complexity, complexity is analyzed in a step by step manner. This is done measuring differences between simulations of a model under different realizations of input forcings. Algorithms are then suggested to estimate model complexity. Model complexities of the two model structures, SAC-SMA (Sacramento Soil Moisture Accounting) and its simplified version SIXPAR (Six Parameter Model), are computed on resampled input data sets from basins that span across the continental US. The model complexities for SIXPAR are estimated for various parameter ranges. It is shown that complexity of SIXPAR increases with lower storage capacity and/or higher recession coefficients. Thus it is argued that a conceptually simple model structure, such as SIXPAR, can be more complex than an intuitively more complex model structure, such as SAC-SMA for certain parameter ranges. We therefore contend that magnitudes of feasible model parameters influence the complexity of the model selection problem just as parameter dimensionality (number of parameters) does and that parameter dimensionality is an incomplete indicator of stability of hydrological model selection and prediction problems.

  5. Measurements of gas parameters in plasma-assisted supersonic combustion processes using diode laser spectroscopy

    International Nuclear Information System (INIS)

    Bolshov, Mikhail A; Kuritsyn, Yu A; Liger, V V; Mironenko, V R; Leonov, S B; Yarantsev, D A

    2009-01-01

    We report a procedure for temperature and water vapour concentration measurements in an unsteady-state combustion zone using diode laser absorption spectroscopy. The procedure involves measurements of the absorption spectrum of water molecules around 1.39 μm. It has been used to determine hydrogen combustion parameters in M = 2 gas flows in the test section of a supersonic wind tunnel. The relatively high intensities of the absorption lines used have enabled direct absorption measurements. We describe a differential technique for measurements of transient absorption spectra, the procedure we used for primary data processing and approaches for determining the gas temperature and H 2 O concentration in the probed zone. The measured absorption spectra are fitted with spectra simulated using parameters from spectroscopic databases. The combustion-time-averaged (∼50 ms) gas temperature and water vapour partial pressure in the hot wake region are determined to be 1050 K and 21 Torr, respectively. The large signal-to-noise ratio in our measurements allowed us to assess the temporal behaviour of these parameters. The accuracy in our temperature measurements in the probed zone is ∼40 K. (laser applications and other topics in quantum electronics)

  6. A new inductive method for measuring the RRR-value of niobium

    International Nuclear Information System (INIS)

    Bolore, M.; Bonin, B.; Boudigou, Y.; Heuveline, S.; Jacques, E.; Jaidane, S.; Koechlin, F.; Safa, H.

    1996-01-01

    A new method for measuring the RRR-value of niobium is presented. The principle of the measurement uses low frequency induction in a niobium sheet placed close to a pair of coils. In contrast with the usual resistive method, the present one gives information on the local value of the RRR, with a spatial resolution of the order of 1 cm. In addition, it is non destructive, thus opening the way to mapping RRR measurements on cavities. This tool will permit the measure of RRR inhomogeneities in cavities due to sheet forming or heat treatments, and the systematic check of the quality of weld seams. (author)

  7. Contrast-enhanced 3T MR perfusion of musculoskeletal tumours. T1 value heterogeneity assessment and evaluation of the influence of T1 estimation methods on quantitative parameters

    Energy Technology Data Exchange (ETDEWEB)

    Gondim Teixeira, Pedro Augusto; Leplat, Christophe; Verbizier, Jacques de; Blum, Alain [Hopital Central, CHRU-Nancy, Service d' Imagerie Guilloz, Nancy (France); Chen, Bailiang; Beaumont, Marine [Universite de Lorraine, Laboratoire IADI, UMR S 947, Nancy (France); Badr, Sammy; Cotten, Anne [CHRU Lille Centre de Consultations et d' Imagerie de l' Appareil Locomoteur, Department of Radiology and Musculoskeletal Imaging, Lille (France)

    2017-12-15

    To evaluate intra-tumour and striated muscle T1 value heterogeneity and the influence of different methods of T1 estimation on the variability of quantitative perfusion parameters. Eighty-two patients with a histologically confirmed musculoskeletal tumour were prospectively included in this study and, with ethics committee approval, underwent contrast-enhanced MR perfusion and T1 mapping. T1 value variations in viable tumour areas and in normal-appearing striated muscle were assessed. In 20 cases, normal muscle perfusion parameters were calculated using three different methods: signal based and gadolinium concentration based on fixed and variable T1 values. Tumour and normal muscle T1 values were significantly different (p = 0.0008). T1 value heterogeneity was higher in tumours than in normal muscle (variation of 19.8% versus 13%). The T1 estimation method had a considerable influence on the variability of perfusion parameters. Fixed T1 values yielded higher coefficients of variation than variable T1 values (mean 109.6 ± 41.8% and 58.3 ± 14.1% respectively). Area under the curve was the least variable parameter (36%). T1 values in musculoskeletal tumours are significantly different and more heterogeneous than normal muscle. Patient-specific T1 estimation is needed for direct inter-patient comparison of perfusion parameters. (orig.)

  8. Parameter Estimation of Partial Differential Equation Models

    KAUST Repository

    Xun, Xiaolei

    2013-09-01

    Partial differential equation (PDE) models are commonly used to model complex dynamic systems in applied sciences such as biology and finance. The forms of these PDE models are usually proposed by experts based on their prior knowledge and understanding of the dynamic system. Parameters in PDE models often have interesting scientific interpretations, but their values are often unknown and need to be estimated from the measurements of the dynamic system in the presence of measurement errors. Most PDEs used in practice have no analytic solutions, and can only be solved with numerical methods. Currently, methods for estimating PDE parameters require repeatedly solving PDEs numerically under thousands of candidate parameter values, and thus the computational load is high. In this article, we propose two methods to estimate parameters in PDE models: a parameter cascading method and a Bayesian approach. In both methods, the underlying dynamic process modeled with the PDE model is represented via basis function expansion. For the parameter cascading method, we develop two nested levels of optimization to estimate the PDE parameters. For the Bayesian method, we develop a joint model for data and the PDE and develop a novel hierarchical model allowing us to employ Markov chain Monte Carlo (MCMC) techniques to make posterior inference. Simulation studies show that the Bayesian method and parameter cascading method are comparable, and both outperform other available methods in terms of estimation accuracy. The two methods are demonstrated by estimating parameters in a PDE model from long-range infrared light detection and ranging data. Supplementary materials for this article are available online. © 2013 American Statistical Association.

  9. Rocket measurements within a polar cap arc - Plasma, particle, and electric circuit parameters

    Science.gov (United States)

    Weber, E. J.; Ballenthin, J. O.; Basu, S.; Carlson, H. C.; Hardy, D. A.; Maynard, N. C.; Kelley, M. C.; Fleischman, J. R.; Pfaff, R. F.

    1989-01-01

    Results are presented from the Polar Ionospheric Irregularities Experiment (PIIE), conducted from Sondrestrom, Greenland, on March 15, 1985, designed for an investigation of processes which lead to the generation of small-scale (less than 1 km) ionospheric irregularities within polar-cap F-layer auroras. An instrumented rocket was launched into a polar cap F layer aurora to measure energetic electron flux, plasma, and electric circuit parameters of a sun-aligned arc, coordinated with simultaneous measurements from the Sondrestrom incoherent scatter radar and the AFGL Airborne Ionospheric Observatory. Results indicated the existence of two different generation mechanisms on the dawnside and duskside of the arc. On the duskside, parameters are suggestive of an interchange process, while on the dawnside, fluctuation parameters are consistent with a velocity shear instability.

  10. Precision half-life measurement of 11C: The most precise mirror transition F t value

    Science.gov (United States)

    Valverde, A. A.; Brodeur, M.; Ahn, T.; Allen, J.; Bardayan, D. W.; Becchetti, F. D.; Blankstein, D.; Brown, G.; Burdette, D. P.; Frentz, B.; Gilardy, G.; Hall, M. R.; King, S.; Kolata, J. J.; Long, J.; Macon, K. T.; Nelson, A.; O'Malley, P. D.; Skulski, M.; Strauss, S. Y.; Vande Kolk, B.

    2018-03-01

    Background: The precise determination of the F t value in T =1 /2 mixed mirror decays is an important avenue for testing the standard model of the electroweak interaction through the determination of Vu d in nuclear β decays. 11C is an interesting case, as its low mass and small QE C value make it particularly sensitive to violations of the conserved vector current hypothesis. The present dominant source of uncertainty in the 11CF t value is the half-life. Purpose: A high-precision measurement of the 11C half-life was performed, and a new world average half-life was calculated. Method: 11C was created by transfer reactions and separated using the TwinSol facility at the Nuclear Science Laboratory at the University of Notre Dame. It was then implanted into a tantalum foil, and β counting was used to determine the half-life. Results: The new half-life, t1 /2=1220.27 (26 ) s, is consistent with the previous values but significantly more precise. A new world average was calculated, t1/2 world=1220.41 (32 ) s, and a new estimate for the Gamow-Teller to Fermi mixing ratio ρ is presented along with standard model correlation parameters. Conclusions: The new 11C world average half-life allows the calculation of a F tmirror value that is now the most precise value for all superallowed mixed mirror transitions. This gives a strong impetus for an experimental determination of ρ , to allow for the determination of Vu d from this decay.

  11. Measuring the Value of Placements to Employers: A Cost-Benefit Approach

    Science.gov (United States)

    Wond, Tracey; Rambukwella, Shan

    2018-01-01

    This article explores the concept and measurement of placement value, underexplored in theory and practice to date. The article makes a theoretical contribution to the placement value discourse by examining and articulating the placement value concept. It also offers a practical contribution by exploring a piloted tool to evaluate employer…

  12. The Impact of Corporate Governance on Financial Performance: (Measured using Accounting and Value-Added based Measures): Evidence from Malaysia

    OpenAIRE

    Abdul Aziz, Khairul Annuar

    2005-01-01

    This paper aims to test empirically which measure, an accounting based financial performance measure such as Return on Equity, Price to Earnings Ratio, Earnings Per Share and Return on Capital Employed; or value-added based financial performance measures such as Economic Value Added and Market Value Added; is more closely related with Corporate Governance Compliance. This paper also aims to study the level of Corporate Governance Compliance of the Smaller Companies listed on the KLSE, the mea...

  13. Two-detector cross-correlation noise technique and its application in measuring reactor kinetic parameters

    International Nuclear Information System (INIS)

    Lu Guiping; Peng Feng; Yi Jieyi

    1988-01-01

    The two-detector cross-correlation noise technique is a new method of measuring reactor kinetic parameters developed in the sixties. It has the advantages of non-perturbation in core, high signal to noise ratio, low space dependent effect, and simple and reliable in measurement. A special set of cross-correlation analyzer has been prepared for measuring kinetic parameters of several reactor assemblies, such as the High Flux Engineering Test Reactor, its zero power mock up facility and a low enriched uranium light water lattice zero power facility

  14. Factors influencing the robustness of P-value measurements in CT texture prognosis studies

    Science.gov (United States)

    McQuaid, Sarah; Scuffham, James; Alobaidli, Sheaka; Prakash, Vineet; Ezhil, Veni; Nisbet, Andrew; South, Christopher; Evans, Philip

    2017-07-01

    Several studies have recently reported on the value of CT texture analysis in predicting survival, although the topic remains controversial, with further validation needed in order to consolidate the evidence base. The aim of this study was to investigate the effect of varying the input parameters in the Kaplan-Meier analysis, to determine whether the resulting P-value can be considered to be a robust indicator of the parameter’s prognostic potential. A retrospective analysis of the CT-based normalised entropy of 51 patients with lung cancer was performed and overall survival data for these patients were collected. A normalised entropy cut-off was chosen to split the patient cohort into two groups and log-rank testing was performed to assess the survival difference of the two groups. This was repeated for varying normalised entropy cut-offs and varying follow-up periods. Our findings were also compared with previously published results to assess robustness of this parameter in a multi-centre patient cohort. The P-value was found to be highly sensitive to the choice of cut-off value, with small changes in cut-off producing substantial changes in P. The P-value was also sensitive to follow-up period, with particularly noisy results at short follow-up periods. Using matched conditions to previously published results, a P-value of 0.162 was obtained. Survival analysis results can be highly sensitive to the choice in texture cut-off value in dichotomising patients, which should be taken into account when performing such studies to avoid reporting false positive results. Short follow-up periods also produce unstable results and should therefore be avoided to ensure the results produced are reproducible. Previously published findings that indicated the prognostic value of normalised entropy were not replicated here, but further studies with larger patient numbers would be required to determine the cause of the different outcomes.

  15. Asymmetrical effects of mesophyll conductance on fundamental photosynthetic parameters and their relationships estimated from leaf gas exchange measurements.

    Science.gov (United States)

    Sun, Ying; Gu, Lianhong; Dickinson, Robert E; Pallardy, Stephen G; Baker, John; Cao, Yonghui; DaMatta, Fábio Murilo; Dong, Xuejun; Ellsworth, David; Van Goethem, Davina; Jensen, Anna M; Law, Beverly E; Loos, Rodolfo; Martins, Samuel C Vitor; Norby, Richard J; Warren, Jeffrey; Weston, David; Winter, Klaus

    2014-04-01

    Worldwide measurements of nearly 130 C3 species covering all major plant functional types are analysed in conjunction with model simulations to determine the effects of mesophyll conductance (g(m)) on photosynthetic parameters and their relationships estimated from A/Ci curves. We find that an assumption of infinite g(m) results in up to 75% underestimation for maximum carboxylation rate V(cmax), 60% for maximum electron transport rate J(max), and 40% for triose phosphate utilization rate T(u) . V(cmax) is most sensitive, J(max) is less sensitive, and T(u) has the least sensitivity to the variation of g(m). Because of this asymmetrical effect of g(m), the ratios of J(max) to V(cmax), T(u) to V(cmax) and T(u) to J(max) are all overestimated. An infinite g(m) assumption also limits the freedom of variation of estimated parameters and artificially constrains parameter relationships to stronger shapes. These findings suggest the importance of quantifying g(m) for understanding in situ photosynthetic machinery functioning. We show that a nonzero resistance to CO2 movement in chloroplasts has small effects on estimated parameters. A non-linear function with gm as input is developed to convert the parameters estimated under an assumption of infinite gm to proper values. This function will facilitate gm representation in global carbon cycle models. © 2013 John Wiley & Sons Ltd.

  16. Determination of K shell absorption jump factors and jump ratios of 3d transition metals by measuring K shell fluorescence parameters.

    Science.gov (United States)

    Kaçal, Mustafa Recep; Han, İbrahim; Akman, Ferdi

    2015-01-01

    Energy dispersive X-ray fluorescence technique (EDXRF) has been employed for measuring K-shell absorption jump factors and jump ratios for Ti, Cr, Fe, Co, Ni and Cu elements. The jump factors and jump ratios for these elements were determined by measuring K shell fluorescence parameters such as the Kα X-ray production cross-sections, K shell fluorescence yields, Kβ-to-Kα X-rays intensity ratios, total atomic absorption cross sections and mass attenuation coefficients. The measurements were performed using a Cd-109 radioactive point source and an Si(Li) detector in direct excitation and transmission experimental geometry. The measured values for jump factors and jump ratios were compared with theoretically calculated and the ones available in the literature. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. A distributed approach for parameters estimation in System Biology models

    International Nuclear Information System (INIS)

    Mosca, E.; Merelli, I.; Alfieri, R.; Milanesi, L.

    2009-01-01

    Due to the lack of experimental measurements, biological variability and experimental errors, the value of many parameters of the systems biology mathematical models is yet unknown or uncertain. A possible computational solution is the parameter estimation, that is the identification of the parameter values that determine the best model fitting respect to experimental data. We have developed an environment to distribute each run of the parameter estimation algorithm on a different computational resource. The key feature of the implementation is a relational database that allows the user to swap the candidate solutions among the working nodes during the computations. The comparison of the distributed implementation with the parallel one showed that the presented approach enables a faster and better parameter estimation of systems biology models.

  18. Identification of Combined Power Quality Disturbances Using Singular Value Decomposition (SVD and Total Least Squares-Estimation of Signal Parameters via Rotational Invariance Techniques (TLS-ESPRIT

    Directory of Open Access Journals (Sweden)

    Huaishuo Xiao

    2017-11-01

    Full Text Available In order to identify various kinds of combined power quality disturbances, the singular value decomposition (SVD and the improved total least squares-estimation of signal parameters via rotational invariance techniques (TLS-ESPRIT are combined as the basis of disturbance identification in this paper. SVD is applied to identify the catastrophe points of disturbance intervals, based on which the disturbance intervals are segmented. Then the improved TLS-ESPRIT optimized by singular value norm method is used to analyze each data segment, and extract the amplitude, frequency, attenuation coefficient and initial phase of various kinds of disturbances. Multi-group combined disturbance test signals are constructed by MATLAB and the proposed method is also tested by the measured data of IEEE Power and Energy Society (PES Database. The test results show that the new method proposed has a relatively higher accuracy than conventional TLS-ESPRIT, which could be used in the identification of measured data.

  19. Prognostic value of (18)F-FDG PET/CT volumetric parameters in recurrent epithelial ovarian cancer.

    Science.gov (United States)

    Mayoral, M; Fernandez-Martinez, A; Vidal, L; Fuster, D; Aya, F; Pavia, J; Pons, F; Lomeña, F; Paredes, P

    2016-01-01

    Metabolic tumour volume (MTV) and total lesion glycolysis (TLG) from (18)F-FDG PET/CT are emerging prognostic biomarkers in various solid neoplasms. These volumetric parameters and the SUVmax have shown to be useful criteria for disease prognostication in preoperative and post-treatment epithelial ovarian cancer (EOC) patients. The purpose of this study was to evaluate the utility of (18)F-FDG PET/CT measurements to predict survival in patients with recurrent EOC. Twenty-six patients with EOC who underwent a total of 31 (18)F-FDG PET/CT studies for suspected recurrence were retrospectively included. SUVmax and volumetric parameters whole-body MTV (wbMTV) and whole-body TLG (wbTLG) with a threshold of 40% and 50% of the SUVmax were obtained. Correlation between PET parameters and progression-free survival (PFS) and the survival analysis of prognostic factors were calculated. Serous cancer was the most common histological subtype (76.9%). The median PFS was 12.5 months (range 10.7-20.6 months). Volumetric parameters showed moderate inverse correlation with PFS but there was no significant correlation in the case of SUVmax. The correlation was stronger for first recurrences. By Kaplan-Meier analysis and log-rank test, wbMTV 40%, wbMTV 50% and wbTLG 50% correlated with PFS. However, SUVmax and wbTLG 40% were not statistically significant predictors for PFS. Volumetric parameters wbMTV and wbTLG 50% measured by (18)F-FDG PET/CT appear to be useful prognostic predictors of outcome and may provide valuable information to individualize treatment strategies in patients with recurrent EOC. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  20. Boundedness and global robust stability analysis of delayed complex-valued neural networks with interval parameter uncertainties.

    Science.gov (United States)

    Song, Qiankun; Yu, Qinqin; Zhao, Zhenjiang; Liu, Yurong; Alsaadi, Fuad E

    2018-07-01

    In this paper, the boundedness and robust stability for a class of delayed complex-valued neural networks with interval parameter uncertainties are investigated. By using Homomorphic mapping theorem, Lyapunov method and inequality techniques, sufficient condition to guarantee the boundedness of networks and the existence, uniqueness and global robust stability of equilibrium point is derived for the considered uncertain neural networks. The obtained robust stability criterion is expressed in complex-valued LMI, which can be calculated numerically using YALMIP with solver of SDPT3 in MATLAB. An example with simulations is supplied to show the applicability and advantages of the acquired result. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Using linear time-invariant system theory to estimate kinetic parameters directly from projection measurements

    International Nuclear Information System (INIS)

    Zeng, G.L.; Gullberg, G.T.

    1995-01-01

    It is common practice to estimate kinetic parameters from dynamically acquired tomographic data by first reconstructing a dynamic sequence of three-dimensional reconstructions and then fitting the parameters to time activity curves generated from the time-varying reconstructed images. However, in SPECT, the pharmaceutical distribution can change during the acquisition of a complete tomographic data set, which can bias the estimated kinetic parameters. It is hypothesized that more accurate estimates of the kinetic parameters can be obtained by fitting to the projection measurements instead of the reconstructed time sequence. Estimation from projections requires the knowledge of their relationship between the tissue regions of interest or voxels with particular kinetic parameters and the project measurements, which results in a complicated nonlinear estimation problem with a series of exponential factors with multiplicative coefficients. A technique is presented in this paper where the exponential decay parameters are estimated separately using linear time-invariant system theory. Once the exponential factors are known, the coefficients of the exponentials can be estimated using linear estimation techniques. Computer simulations demonstrate that estimation of the kinetic parameters directly from the projections is more accurate than the estimation from the reconstructed images

  2. International Target Values 2010 for Measurement Uncertainties in Safeguarding Nuclear Materials

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, M.; Penkin, M.; Norman, C.; Balsley, S. [IAEA, Vienna (Australia); others, and

    2012-12-15

    This issue of the International Target Values (ITVs) represents the sixth revision, following the first release of such tables issued in 1979 by the ESARDA/WGDA. The ITVs are uncertainties to be considered in judging the reliability of analytical techniques applied to industrial nuclear and fissile material, which are subject to safeguards verification. The tabulated values represent estimates of the 'state of the practice' which should be achievable under routine measurement conditions. The most recent standard conventions in representing uncertainty have been considered, while maintaining a format that allows comparison with the previous releases of the ITVs. The present report explains why target values are needed, how the concept evolved and how they relate to the operator's and inspector's measurement systems. The ITVs-2010 are intended to be used by plant operators and safeguards organizations, as a reference of the quality of measurements achievable in nuclear material accountancy, and for planning purposes. The report suggests that the use of ITVs can be beneficial for statistical inferences regarding the significance of operator-inspector differences whenever valid performance values are not available.

  3. CORRECTION OF GLOBAL AND REFLEX RADIATION VALUES MEASURED ABOVE THE LAKE BALATON

    Directory of Open Access Journals (Sweden)

    Laszlo Menyhart

    2014-03-01

    Full Text Available Albedo measurements have been carried out since 2007 above the Lake Balaton near Keszthely and Siofok. It turned out that a systematic offset error was superposed to both the global and the reflex radiation. The value of this systematic error was approximately constant per pyranometer within a year but on the other hand it varied from year to year and from pyranometer to pyranometer. In this paper the values of this systematic errors were determined with two different methods. The difference between the values measured at night-time and the intrinsic thermal offset error of pyranometers were examined with both methods. The base of the first method is the empirical observation, that the values measured at night-time by a global radiometer are typically negative whereas by a reflex radiometer are typically positive. The substance of the second method is utilizing the air temperature measured within 1 as well as 5 hours before the radiation measuring to +select the fully overcast nights, when the thermal offset error of the global radiometer is zero. In addition, the cases where the thermal offset error of the reflex radiometer is zero were selected on the basis of the difference between water and air temperature. When the thermal offset error is zero the measured value is equal to the systematic error. Comparing the results of the two methods showed that the systematic error of the global radiometer were determined with uncertainty of 1 Wm–2, whereas that of the reflex radiometer with uncertainty of 2 Wm–2. The calibration constants were recalculated from the values being in the calibration reports taking the systematic errors into account.

  4. Variation of nonlinearity parameter at low fundamental amplitudes

    Science.gov (United States)

    Barnard, Daniel J.

    1999-04-01

    Recent harmonic generation measurements of the nonlinearity parameter β in polycrystalline Cu-Al alloys have shown a transition to lower values at low fundamental amplitude levels. Values for β at high (>10 Å) fundamental levels are in the range predicted by single-crystal second- and third-order elastic constants while lower fundamental levels (alloy by others. The source of the effect is unclear but initial results may require a reexamination of current methods for measurement of third-order elastic constants.

  5. A proposed method for fast determination of plasma parameters

    International Nuclear Information System (INIS)

    Braams, B.J.; Lackner, K.

    1984-09-01

    The method of function parametrization, developed and applied by H. Wind for fast data evaluation in high energy physics, is presented in the context of controlled fusion research. This method relies on statistical analysis of a data base of simulated experiments in order to obtain a functional representation for the intrinsic physical parameters of a system in terms of the values of the measurements. Some variations on Wind's original procedure are suggested. A specific application for tokamak experiments would be the determination of certain global parameters of the plasma, characterizing the current profile, shape of the cross-section, plasma pressure, and the internal inductance. The relevant measurements for this application include values of the poloidal field and flux external to the plasma, and a diamagnetic measurement. These may be combined with other diagnostics, such as electron-cyclotron emission and laser interferometry, in order to obtain also density and temperature profiles. There appears to be a capability for on-line determination of basic physical parameters, in a millisecond timescale on a minicomputer instead of in seconds on a large mainframe. (orig.)

  6. Measuring Cosmological Parameters with Photometrically Classified Pan-STARRS Supernovae

    Science.gov (United States)

    Jones, David; Scolnic, Daniel; Riess, Adam; Rest, Armin; Kirshner, Robert; Berger, Edo; Kessler, Rick; Pan, Yen-Chen; Foley, Ryan; Chornock, Ryan; Ortega, Carolyn; Challis, Peter; Burgett, William; Chambers, Kenneth; Draper, Peter; Flewelling, Heather; Huber, Mark; Kaiser, Nick; Kudritzki, Rolf; Metcalfe, Nigel; Tonry, John; Wainscoat, Richard J.; Waters, Chris; Gall, E. E. E.; Kotak, Rubina; McCrum, Matt; Smartt, Stephen; Smith, Ken

    2018-01-01

    We use nearly 1,200 supernovae (SNe) from Pan-STARRS and ~200 low-z (z energy equation of state parameter w to be -0.986±0.058 (stat+sys). If we allow w to evolve with redshift as w(a) = w0 + wa(1-a), we find w0 = -0.923±0.148 and wa = -0.404±0.797. These results are consistent with measurements of cosmological parameters from the JLA and from a new analysis of 1049 spectroscopically confirmed SNe Ia (Scolnic et al. 2017). We try four different photometric classification priors for Pan-STARRS SNe and two alternate ways of modeling the CC SN contamination, finding that none of these variants gives a w that differs by more than 1% from the baseline measurement. The systematic uncertainty on w due to marginalizing over the CC SN contamination, σwCC = 0.019, is approximately equal to the photometric calibration uncertainty and is lower than the systematic uncertainty in the SN\\,Ia dispersion model (σwdisp = 0.024). Our data provide one of the best current constraints on w, demonstrating that samples with ~5% CC SN contamination can give competitive cosmological constraints when the contaminating distribution is marginalized over in a Bayesian framework.

  7. Accurate Estimation of Low Fundamental Frequencies from Real-Valued Measurements

    DEFF Research Database (Denmark)

    Christensen, Mads Græsbøll

    2013-01-01

    In this paper, the difficult problem of estimating low fundamental frequencies from real-valued measurements is addressed. The methods commonly employed do not take the phenomena encountered in this scenario into account and thus fail to deliver accurate estimates. The reason for this is that the......In this paper, the difficult problem of estimating low fundamental frequencies from real-valued measurements is addressed. The methods commonly employed do not take the phenomena encountered in this scenario into account and thus fail to deliver accurate estimates. The reason...... for this is that they employ asymptotic approximations that are violated when the harmonics are not well-separated in frequency, something that happens when the observed signal is real-valued and the fundamental frequency is low. To mitigate this, we analyze the problem and present some exact fundamental frequency estimators...

  8. Uncertainty In Measuring Noise Parameters Of a Communication Receiver

    International Nuclear Information System (INIS)

    Korcz, Karol; Palczynska, Beata; Spiralski, Ludwik

    2005-01-01

    The paper presents the method of assessing uncertainty in measuring the usable sensitivity Es of communication receiver. The influence of partial uncertainties of measuring the noise factor F and the energy pass band of the receiver Δf on the combined standard uncertainty level is analyzed. The method to assess the uncertainty in measuring the noise factor on the basis of the systematic component of uncertainty, assuming that the main source of measurement uncertainty is the hardware of the measuring system, is proposed. The assessment of uncertainty in measuring the pass band of the receiver is determined with the assumption that input quantities of the measurement equation are not correlated. They are successive, discrete values of the spectral power density of the noise on the output of receiver. The results of the analyses of particular uncertainties components of measuring the sensitivity, which were carried out for a typical communication receiver, are presented

  9. Parameters of anaerobic physiological profile of elite athletes

    Directory of Open Access Journals (Sweden)

    Karaba-Jakovljević Dea

    2015-01-01

    Full Text Available Introduction. Anaerobic capacity is much less evaluated in literature compared to aerobic component. Anaerobic performance of athletes can be measured using different motoric tests, lasting 20 to 30 seconds, one of them being the Wingate anaerobic test (WAnT. Objective. The aim of this study was to determine the work performed and power generated by athletes and non-athletes during a 30-second high intensity exercise, as well as to compare explosive characteristics of subjects using a new parameter of WAnT, named explosive power, or slope of power. Methods. All parameters of anaerobic power were investigated in 152 subjects classed into different groups depending on their physical fitness and sport specialties as follows: non-athletes (n=31, rowers (n=26, volleyball players (n=37, handball players (n=34 and judo players (n=24. The WAnT, as well as basic anthropometric measurements, was administrated to all participants. Results. Values of anaerobic parameters were higher in the group of athletes compared to physically inactive subjects. The highest values of the WAnT parameters were registered in the group of volleyball players (AP=1006 W; relative AP=11.4 W/ kg, AC=19.8 kJ, compared to athletes of other sport disciplines (volleyball, rowing and judo. The new parameter of the WAnT, explosive power, also showed highest values in volleyball players (EP=154 W/s; relative EP=1.74 W/s/kg. These differences were statistically significant (p<0.05. Conclusion. The results of laboratory tests can provide useful information on improvements in training processes. The new parameter of the WAnT could be implemented in further analyses of explosive characteristics of muscle contraction.

  10. Baseline values of immunologic parameters in the lizard Salvator merianae (Teiidae, Squamata)

    Science.gov (United States)

    Mestre, Ana Paula; Amavet, Patricia Susana; Siroski, Pablo Ariel

    2017-01-01

    The genus Salvator is widely distributed throughout South America. In Argentina, the species most abundant widely distributed is Salvator merianae. Particularly in Santa Fe province, the area occupied by populations of these lizards overlaps with areas where agriculture was extended. With the aim of established baseline values for four immunologic biomarkers widely used, 36 tegu lizards were evaluated tacking into account different age classes and both sexes. Total leukocyte counts were not different between age classes. Of the leucocytes count, eosinophils levels were higher in neonates compared with juvenile and adults; nevertheless, the heterophils group was the most prevalent leukocyte in the peripheral blood in all age classes. Lymphocytes, monocytes, heterophils, azurophils and basophils levels did not differ with age. Natural antibodies titres were higher in the adults compared with neonates and juveniles lizards. Lastly, complement system activity was low in neonates compared with juveniles and adults. Statistical analysis within each age group showed that gender was not a factor in the outcomes. Based on the results, we concluded that S. merianae demonstrated age (but not gender) related differences in the immune parameters analyzed. Having established baseline values for these four widely-used immunologic biomarkers, ongoing studies will seek to optimize the use of the S. merianae model in future research. PMID:28652981

  11. Baseline values of immunologic parameters in the lizard Salvator merianae (Teiidae, Squamata).

    Science.gov (United States)

    Mestre, Ana Paula; Amavet, Patricia Susana; Siroski, Pablo Ariel

    2017-01-01

    The genus Salvator is widely distributed throughout South America. In Argentina, the species most abundant widely distributed is Salvator merianae . Particularly in Santa Fe province, the area occupied by populations of these lizards overlaps with areas where agriculture was extended. With the aim of established baseline values for four immunologic biomarkers widely used, 36 tegu lizards were evaluated tacking into account different age classes and both sexes. Total leukocyte counts were not different between age classes. Of the leucocytes count, eosinophils levels were higher in neonates compared with juvenile and adults; nevertheless, the heterophils group was the most prevalent leukocyte in the peripheral blood in all age classes. Lymphocytes, monocytes, heterophils, azurophils and basophils levels did not differ with age. Natural antibodies titres were higher in the adults compared with neonates and juveniles lizards. Lastly, complement system activity was low in neonates compared with juveniles and adults. Statistical analysis within each age group showed that gender was not a factor in the outcomes. Based on the results, we concluded that S. merianae demonstrated age (but not gender) related differences in the immune parameters analyzed. Having established baseline values for these four widely-used immunologic biomarkers, ongoing studies will seek to optimize the use of the S. merianae model in future research.

  12. Baseline values of immunologic parameters in the lizard Salvator merianae (Teiidae, Squamata

    Directory of Open Access Journals (Sweden)

    Ana Paula Mestre

    2017-05-01

    Full Text Available The genus Salvator is widely distributed throughout South America. In Argentina, the species most abundant widely distributed is Salvator merianae. Particularly in Santa Fe province, the area occupied by populations of these lizards overlaps with areas where agriculture was extended. With the aim of established baseline values for four immunologic biomarkers widely used, 36 tegu lizards were evaluated tacking into account different age classes and both sexes. Total leukocyte counts were not different between age classes. Of the leucocytes count, eosinophils levels were higher in neonates compared with juvenile and adults; nevertheless, the heterophils group was the most prevalent leukocyte in the peripheral blood in all age classes. Lymphocytes, monocytes, heterophils, azurophils and basophils levels did not differ with age. Natural antibodies titres were higher in the adults compared with neonates and juveniles lizards. Lastly, complement system activity was low in neonates compared with juveniles and adults. Statistical analysis within each age group showed that gender was not a factor in the outcomes. Based on the results, we concluded that S. merianae demonstrated age (but not gender related differences in the immune parameters analyzed. Having established baseline values for these four widely-used immunologic biomarkers, ongoing studies will seek to optimize the use of the S. merianae model in future research.

  13. A double parameters measurement of steam-water two-phase flow with single orifice

    International Nuclear Information System (INIS)

    Zhong Shuoping; Tong Yunxian; Yu Meiying

    1992-08-01

    A double parameters measurement of steam-water two-phase flow with single orifice is described. An on-line measurement device based on micro-computer has been developed. The measured r.m.s error of steam quality is less than 6.5% and the measured relative r.m.s. error of mass flow rate is less than 9%

  14. The use of personal values in living standards measures | Ungerer ...

    African Journals Online (AJOL)

    The Living Standards Measure (LSM), a South African marketing segmentation method, is a multivariate wealth measure based on standard of living. This article reports on whether a rationale can be found for the inclusion of psychological variables, particularly personal values, in this type of multivariate segmentation.

  15. Consistency in color parameters of a commonly used shade guide.

    Science.gov (United States)

    Tashkandi, Esam

    2010-01-01

    The use of shade guides to assess the color of natural teeth subjectively remains one of the most common means for dental shade assessment. Any variation in the color parameters of the different shade guides may lead to significant clinical implications. Particularly, since the communication between the clinic and the dental laboratory is based on using the shade guide designation. The purpose of this study was to investigate the consistency of the L∗a∗b∗ color parameters of a sample of a commonly used shade guide. The color parameters of a total of 100 VITAPAN Classical Vacuum shade guide (VITA Zahnfabrik, Bad Säckingen, Germany(were measured using a X-Rite ColorEye 7000A Spectrophotometer (Grand Rapids, Michigan, USA). Each shade guide consists of 16 tabs with different designations. Each shade tab was measured five times and the average values were calculated. The ΔE between the average L∗a∗b∗ value for each shade tab and the average of the 100 shade tabs of the same designation was calculated. Using the Student t-test analysis, no significant differences were found among the measured sample. There is a high consistency level in terms of color parameters of the measured VITAPAN Classical Vacuum shade guide sample tested.

  16. Gsolve, a Python computer program with a graphical user interface to transform relative gravity survey measurements to absolute gravity values and gravity anomalies

    Science.gov (United States)

    McCubbine, Jack; Tontini, Fabio Caratori; Stagpoole, Vaughan; Smith, Euan; O'Brien, Grant

    2018-01-01

    A Python program (Gsolve) with a graphical user interface has been developed to assist with routine data processing of relative gravity measurements. Gsolve calculates the gravity at each measurement site of a relative gravity survey, which is referenced to at least one known gravity value. The tidal effects of the sun and moon, gravimeter drift and tares in the data are all accounted for during the processing of the survey measurements. The calculation is based on a least squares formulation where the difference between the absolute gravity at each surveyed location and parameters relating to the dynamics of the gravimeter are minimized with respect to the relative gravity observations, and some supplied gravity reference site values. The program additionally allows the user to compute free air gravity anomalies, with respect to the GRS80 and GRS67 reference ellipsoids, from the determined gravity values and calculate terrain corrections at each of the surveyed sites using a prism formula and a user supplied digital elevation model. This paper reviews the mathematical framework used to reduce relative gravimeter survey observations to gravity values. It then goes on to detail how the processing steps can be implemented using the software.

  17. Field measurements of key parameters associated with nocturnal OBT formation in vegetables grown under Canadian conditions

    International Nuclear Information System (INIS)

    Kim, S.B.; Workman, W.G.; Korolevych, V.; Davis, P.A.

    2012-01-01

    The objective of this study was to provide the parameter values required to model OBT formation in the edible parts of plants following a hypothetical accidental tritium release to the atmosphere at night. The parameters considered were leaf area index, stomatal resistance, photosynthesis rate, the photosynthetic production rate of starch, the nocturnal hydrolysis rate of starch, the fraction of starch produced daily by photosynthesis that appears in the fruits, and the mass of the fruit. Values of these parameters were obtained in the summer of 2002 for lettuce, radishes and tomatoes grown under typical Canadian environmental conditions. Based on the maximum observed photosynthetic rate and growth rate, the fraction of starch translocated to the fruit was calculated to be 17% for tomato fruit and 14% for radish root. - Highlights: ► Plant physiological parameters affecting nocturnal OBT formation have been investigated. ► The fraction of starch produced daily by photosynthesis in the leaves that appears in the fruit was calculated. ► Realistic estimates of OBT concentrations following a nighttime accidental HTO release to the atmosphere.

  18. Measurements of Dune Parameters on Titan Suggest Differences in Sand Availability

    Science.gov (United States)

    Stewart, Brigitte W.; Radebaugh, Jani

    2014-11-01

    The equatorial region of Saturn’s moon Titan has five large sand seas with dunes similar to large linear dunes on Earth. Cassini Radar SAR swaths have high enough resolution (300 m) to measure dune parameters such as width and spacing, which helps inform us about formation conditions and long-term evolution of the sand dunes. Previous measurements in locations scattered across Titan have revealed an average width of 1.3 km and spacing of 2.7 km, with variations by location. We have taken over 1200 new measurements of dune width and spacing in the T8 swath, a region on the leading hemisphere of Titan in the Belet Sand Sea, between -5 and -9 degrees latitude. We have also taken over 500 measurements in the T44 swath, located on the anti-Saturn hemisphere in the Shangri-La Sand Sea, between 0 and 20 degrees latitude. We correlated each group of 50 measurements with the average distance from the edge of the dune field to obtain an estimate of how position within a dune field affects dune parameters. We found that in general, the width and spacing of dunes decreases with distance from the edge of the dune field, consistent with similar measurements in sand seas on Earth. We suggest that this correlation is due to the lesser availability of sand at the edges of dune fields. These measurements and correlations could be helpful in determining differences in sand availability across different dune fields, and along the entire equatorial region of Titan.

  19. Reference value sensitivity of measures of unfair health inequality

    Science.gov (United States)

    García-Gómez, Pilar; Schokkaert, Erik; Van Ourti, Tom

    2014-01-01

    Most politicians and ethical observers are not interested in pure health inequalities, as they want to distinguish between different causes of health differences. Measures of “unfair” inequality - direct unfairness and the fairness gap, but also the popular standardized concentration index - therefore neutralize the effects of what are considered to be “legitimate” causes of inequality. This neutralization is performed by putting a subset of the explanatory variables at reference values, e.g. their means. We analyze how the inequality ranking of different policies depends on the specific choice of reference values. We show with mortality data from the Netherlands that the problem is empirically relevant and we suggest a statistical method for fixing the reference values. PMID:24954998

  20. Planck 2013 results. XVI. Cosmological parameters

    CERN Document Server

    Ade, P.A.R.; Armitage-Caplan, C.; Arnaud, M.; Ashdown, M.; Atrio-Barandela, F.; Aumont, J.; Baccigalupi, C.; Banday, A.J.; Barreiro, R.B.; Bartlett, J.G.; Battaner, E.; Benabed, K.; Benoit, A.; Benoit-Levy, A.; Bernard, J.P.; Bersanelli, M.; Bielewicz, P.; Bobin, J.; Bock, J.J.; Bonaldi, A.; Bond, J.R.; Borrill, J.; Bouchet, F.R.; Bridges, M.; Bucher, M.; Burigana, C.; Butler, R.C.; Calabrese, E.; Cappellini, B.; Cardoso, J.F.; Catalano, A.; Challinor, A.; Chamballu, A.; Chary, R.R.; Chen, X.; Chiang, L.Y.; Chiang, H.C.; Christensen, P.R.; Church, S.; Clements, D.L.; Colombi, S.; Colombo, L.P.L.; Couchot, F.; Coulais, A.; Crill, B.P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R.D.; Davis, R.J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Delouis, J.M.; Desert, F.X.; Dickinson, C.; Diego, J.M.; Dolag, K.; Dole, H.; Donzelli, S.; Dore, O.; Douspis, M.; Dunkley, J.; Dupac, X.; Efstathiou, G.; Elsner, F.; Ensslin, T.A.; Eriksen, H.K.; Finelli, F.; Forni, O.; Frailis, M.; Fraisse, A.A.; Franceschi, E.; Gaier, T.C.; Galeotta, S.; Galli, S.; Ganga, K.; Giard, M.; Giardino, G.; Giraud-Heraud, Y.; Gjerlow, E.; Gonzalez-Nuevo, J.; Gorski, K.M.; Gratton, S.; Gregorio, A.; Gruppuso, A.; Gudmundsson, J.E.; Haissinski, J.; Hamann, J.; Hansen, F.K.; Hanson, D.; Harrison, D.; Henrot-Versille, S.; Hernandez-Monteagudo, C.; Herranz, D.; Hildebrandt, S.R.; Hivon, E.; Hobson, M.; Holmes, W.A.; Hornstrup, A.; Hou, Z.; Hovest, W.; Huffenberger, K.M.; Jaffe, T.R.; Jaffe, A.H.; Jewell, J.; Jones, W.C.; Juvela, M.; Keihanen, E.; Keskitalo, R.; Kisner, T.S.; Kneissl, R.; Knoche, J.; Knox, L.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lahteenmaki, A.; Lamarre, J.M.; Lasenby, A.; Lattanzi, M.; Laureijs, R.J.; Lawrence, C.R.; Leach, S.; Leahy, J.P.; Leonardi, R.; Leon-Tavares, J.; Lesgourgues, J.; Lewis, A.; Liguori, M.; Lilje, P.B.; Linden-Vornle, M.; Lopez-Caniego, M.; Lubin, P.M.; Macias-Perez, J.F.; Maffei, B.; Maino, D.; Mandolesi, N.; Maris, M.; Marshall, D.J.; Martin, P.G.; Martinez-Gonzalez, E.; Masi, S.; Matarrese, S.; Matthai, F.; Mazzotta, P.; Meinhold, P.R.; Melchiorri, A.; Melin, J.B.; Mendes, L.; Menegoni, E.; Mennella, A.; Migliaccio, M.; Millea, M.; Mitra, S.; Miville-Deschenes, M.A.; Moneti, A.; Montier, L.; Morgante, G.; Mortlock, D.; Moss, A.; Munshi, D.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C.B.; Norgaard-Nielsen, H.U.; Noviello, F.; Novikov, D.; Novikov, I.; O'Dwyer, I.J.; Osborne, S.; Oxborrow, C.A.; Paci, F.; Pagano, L.; Pajot, F.; Paoletti, D.; Partridge, B.; Pasian, F.; Patanchon, G.; Pearson, D.; Pearson, T.J.; Peiris, H.V.; Perdereau, O.; Perotto, L.; Perrotta, F.; Pettorino, V.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Platania, P.; Pointecouteau, E.; Polenta, G.; Ponthieu, N.; Popa, L.; Poutanen, T.; Pratt, G.W.; Prezeau, G.; Prunet, S.; Puget, J.L.; Rachen, J.P.; Reach, W.T.; Rebolo, R.; Reinecke, M.; Remazeilles, M.; Renault, C.; Ricciardi, S.; Riller, T.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Roudier, G.; Rowan-Robinson, M.; Rubino-Martin, J.A.; Rusholme, B.; Sandri, M.; Santos, D.; Savelainen, M.; Savini, G.; Scott, D.; Seiffert, M.D.; Shellard, E.P.S.; Spencer, L.D.; Starck, J.L.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sunyaev, R.; Sureau, F.; Sutton, D.; Suur-Uski, A.S.; Sygnet, J.F.; Tauber, J.A.; Tavagnacco, D.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Tuovinen, J.; Turler, M.; Umana, G.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vielva, P.; Villa, F.; Vittorio, N.; Wade, L.A.; Wandelt, B.D.; Wehus, I.K.; White, M.; White, S.D.M.; Wilkinson, A.; Yvon, D.; Zacchei, A.; Zonca, A.

    2014-10-29

    We present the first results based on Planck measurements of the CMB temperature and lensing-potential power spectra. The Planck spectra at high multipoles are extremely well described by the standard spatially-flat six-parameter LCDM cosmology. In this model Planck data determine the cosmological parameters to high precision. We find a low value of the Hubble constant, H0=67.3+/-1.2 km/s/Mpc and a high value of the matter density parameter, Omega_m=0.315+/-0.017 (+/-1 sigma errors) in excellent agreement with constraints from baryon acoustic oscillation (BAO) surveys. Including curvature, we find that the Universe is consistent with spatial flatness to percent-level precision using Planck CMB data alone. We present results from an analysis of extensions to the standard cosmology, using astrophysical data sets in addition to Planck and high-resolution CMB data. None of these models are favoured significantly over standard LCDM. The deviation of the scalar spectral index from unity is insensitive to the additi...

  1. Two statistics for evaluating parameter identifiability and error reduction

    Science.gov (United States)

    Doherty, John; Hunt, Randall J.

    2009-01-01

    Two statistics are presented that can be used to rank input parameters utilized by a model in terms of their relative identifiability based on a given or possible future calibration dataset. Identifiability is defined here as the capability of model calibration to constrain parameters used by a model. Both statistics require that the sensitivity of each model parameter be calculated for each model output for which there are actual or presumed field measurements. Singular value decomposition (SVD) of the weighted sensitivity matrix is then undertaken to quantify the relation between the parameters and observations that, in turn, allows selection of calibration solution and null spaces spanned by unit orthogonal vectors. The first statistic presented, "parameter identifiability", is quantitatively defined as the direction cosine between a parameter and its projection onto the calibration solution space. This varies between zero and one, with zero indicating complete non-identifiability and one indicating complete identifiability. The second statistic, "relative error reduction", indicates the extent to which the calibration process reduces error in estimation of a parameter from its pre-calibration level where its value must be assigned purely on the basis of prior expert knowledge. This is more sophisticated than identifiability, in that it takes greater account of the noise associated with the calibration dataset. Like identifiability, it has a maximum value of one (which can only be achieved if there is no measurement noise). Conceptually it can fall to zero; and even below zero if a calibration problem is poorly posed. An example, based on a coupled groundwater/surface-water model, is included that demonstrates the utility of the statistics. ?? 2009 Elsevier B.V.

  2. Prognostic and diagnostic value of EEG signal coupling measures in coma.

    Science.gov (United States)

    Zubler, Frederic; Koenig, Christa; Steimer, Andreas; Jakob, Stephan M; Schindler, Kaspar A; Gast, Heidemarie

    2016-08-01

    Our aim was to assess the diagnostic and predictive value of several quantitative EEG (qEEG) analysis methods in comatose patients. In 79 patients, coupling between EEG signals on the left-right (inter-hemispheric) axis and on the anterior-posterior (intra-hemispheric) axis was measured with four synchronization measures: relative delta power asymmetry, cross-correlation, symbolic mutual information and transfer entropy directionality. Results were compared with etiology of coma and clinical outcome. Using cross-validation, the predictive value of measure combinations was assessed with a Bayes classifier with mixture of Gaussians. Five of eight measures showed a statistically significant difference between patients grouped according to outcome; one measure revealed differences in patients grouped according to the etiology. Interestingly, a high level of synchrony between the left and right hemisphere was associated with mortality on intensive care unit, whereas higher synchrony between anterior and posterior brain regions was associated with survival. The combination with the best predictive value reached an area-under the curve of 0.875 (for patients with post anoxic encephalopathy: 0.946). EEG synchronization measures can contribute to clinical assessment, and provide new approaches for understanding the pathophysiology of coma. Prognostication in coma remains a challenging task. qEEG could improve current multi-modal approaches. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Optimization of turning process parameters by using grey-Taguchi

    African Journals Online (AJOL)

    DR OKE

    ... India continue to choose the operating conditions solely on the basis of handbook values .... Surface Roughness Measuring instrument ... process control parameters like spindle speed, feed and depth of cut. ..... and Industrial Engineering.

  4. Clinical implications in laboratory parameter values in acute Kawasaki disease for early diagnosis and proper treatment.

    Science.gov (United States)

    Seo, Yu-Mi; Kang, Hyun-Mi; Lee, Sung-Churl; Yu, Jae-Won; Kil, Hong-Ryang; Rhim, Jung-Woo; Han, Ji-Whan; Lee, Kyung-Yil

    2018-05-01

    This study aimed to analyse laboratory values according to fever duration, and evaluate the relationship across these values during the acute phase of Kawasaki disease (KD) to aid in the early diagnosis for early-presenting KD and incomplete KD patients. Clinical and laboratory data of patients with KD (n=615) were evaluated according to duration of fever at presentation, and were compared between patients with and without coronary artery lesions (CALs). For evaluation of the relationships across laboratory indices, patients with a fever duration of 5 days or 6 days were used (n=204). The mean fever duration was 6.6±2.3 days, and the proportions of patients with CALs was 19.3% (n=114). C-reactive proteins (CRPs) and neutrophil differential values were highest and hemoglobin, albumin, and lymphocyte differential values were lowest in the 6-day group. Patients with CALs had longer total fever duration, higher CRP and neutrophil differential values and lower hemoglobin and albumin values compared to patients without CALs. CRP, albumin, neutrophil differential, and hemoglobin values at the peak inflammation stage of KD showed positive or negative correlations each other. The severity of systemic inflammation in KD was reflected in the laboratory values including CRP, neutrophil differential, albumin, and hemoglobin. Observing changes in these laboratory parameters by repeated examinations prior to the peak of inflammation in acute KD may aid in diagnosis of early-presenting KD patients.

  5. Algorithms to analyze the quality test parameter values of seafood in the proposed ontology based seafood quality analyzer and miner (ONTO SQAM model

    Directory of Open Access Journals (Sweden)

    Vinu Sherimon

    2017-07-01

    Full Text Available Ensuring the quality of food, particularly seafood has increasingly become an important issue nowadays. Quality Management Systems empower any organization to identify, measure, control and improve the quality of the products manufactured that will eventually lead to improved business performance. With the advent of new technologies, now intelligent systems are being developed. To ensure the quality of seafood, an ontology based seafood quality analyzer and miner (ONTO SQAM model is proposed. The knowledge is represented using ontology. The domain concepts are defined using ontology. This paper presents the initial part of the proposed model – the analysis of quality test parameter values. Two algorithms are proposed to do the analysis – Comparison Algorithm and Data Store Updater algorithm. The algorithms ensure that the values of various quality tests are in the acceptable range. The real data sets taken from different seafood companies in Kerala, India, and validated by the Marine Product Export Development Authority of India (MPEDA are used for the experiments. The performance of the algorithms is evaluated using standard performance metrics such as precision, recall, and accuracy. The results obtained show that all the three measures achieved good results.

  6. Clustering of reads with alignment-free measures and quality values.

    Science.gov (United States)

    Comin, Matteo; Leoni, Andrea; Schimd, Michele

    2015-01-01

    The data volume generated by Next-Generation Sequencing (NGS) technologies is growing at a pace that is now challenging the storage and data processing capacities of modern computer systems. In this context an important aspect is the reduction of data complexity by collapsing redundant reads in a single cluster to improve the run time, memory requirements, and quality of post-processing steps like assembly and error correction. Several alignment-free measures, based on k-mers counts, have been used to cluster reads. Quality scores produced by NGS platforms are fundamental for various analysis of NGS data like reads mapping and error detection. Moreover future-generation sequencing platforms will produce long reads but with a large number of erroneous bases (up to 15 %). In this scenario it will be fundamental to exploit quality value information within the alignment-free framework. To the best of our knowledge this is the first study that incorporates quality value information and k-mers counts, in the context of alignment-free measures, for the comparison of reads data. Based on this principles, in this paper we present a family of alignment-free measures called D (q) -type. A set of experiments on simulated and real reads data confirms that the new measures are superior to other classical alignment-free statistics, especially when erroneous reads are considered. Also results on de novo assembly and metagenomic reads classification show that the introduction of quality values improves over standard alignment-free measures. These statistics are implemented in a software called QCluster (http://www.dei.unipd.it/~ciompin/main/qcluster.html).

  7. Measurement of key pool boiling parameters in nanofluids for nuclear applications

    International Nuclear Information System (INIS)

    Bang, In Cheol; Buongiorno, Jacopo; Hu, Lin-Wen; Wang, Hsin

    2008-01-01

    Nanofluids, colloidal dispersions of nanoparticles in a base fluid such as water, can afford very significant Critical Heat Flux (CHF) enhancement. Such engineered fluids potentially could be employed in reactors as advanced coolants in safety systems with significant safety and economic advantages. However, a satisfactory explanation of the CHF enhancement mechanism in nanofluids is lacking. To close this gap, we have identified the important boiling parameters to be measured. These are the properties (e.g., density, viscosity, thermal conductivity, specific heat, vaporization enthalpy, surface tension), hydrodynamic parameters (i.e., bubble size, bubble velocity, departure frequency, hot/dry spot dynamics) and surface conditions (i.e., contact angle, nucleation site density). We have also deployed a pool boiling facility in which many such parameters can be measured. The facility is equipped with a thin indium-tin-oxide heater deposited over a sapphire substrate. An infra-red high-speed camera and an optical probe are used to measure the temperature distribution on the heater and the hydrodynamics above the heater, respectively. The first data generated with this facility already provide some clue on the CHF enhancement mechanism in nanofluids. Specifically, the progression to burnout in a pure fluid (ethanol in this case) is characterized by a smoothly-shaped and steadily-expanding hot spot. By contrast, in the ethanol-based nanofluid the hot spot pulsates and the progression to burnout lasts longer, although the nanofluid CHF is higher than the pure fluid CHF. The presence of a nanoparticle deposition layer on the heater surface seems to enhance wettability and aid hot spot dissipation, thus delaying burnout. (author)

  8. Ultra-Weak Fiber Bragg Grating Sensing Network Coated with Sensitive Material for Multi-Parameter Measurements

    Directory of Open Access Journals (Sweden)

    Wei Bai

    2017-06-01

    Full Text Available A multi-parameter measurement system based on ultra-weak fiber Bragg grating (UFBG array with sensitive material was proposed and experimentally demonstrated. The UFBG array interrogation principle is time division multiplex technology with two semiconductor optical amplifiers as timing units. Experimental results showed that the performance of the proposed UFBG system is almost equal to that of traditional FBG, while the UFBG array system has obvious superiority with potential multiplexing ability for multi-point and multi-parameter measurement. The system experimented on a 144 UFBG array with the reflectivity of UFBG ~0.04% for the four target parameters: hydrogen, humidity, temperature and salinity. Moreover, a uniform solution was customized to divide the cross-sensitivity between temperature and other target parameters. It is expected that this scheme will be capable of handling thousands of multi-parameter sensors in a single fiber.

  9. Ultra-Weak Fiber Bragg Grating Sensing Network Coated with Sensitive Material for Multi-Parameter Measurements.

    Science.gov (United States)

    Bai, Wei; Yang, Minghong; Hu, Chenyuan; Dai, Jixiang; Zhong, Xuexiang; Huang, Shuai; Wang, Gaopeng

    2017-06-26

    A multi-parameter measurement system based on ultra-weak fiber Bragg grating (UFBG) array with sensitive material was proposed and experimentally demonstrated. The UFBG array interrogation principle is time division multiplex technology with two semiconductor optical amplifiers as timing units. Experimental results showed that the performance of the proposed UFBG system is almost equal to that of traditional FBG, while the UFBG array system has obvious superiority with potential multiplexing ability for multi-point and multi-parameter measurement. The system experimented on a 144 UFBG array with the reflectivity of UFBG ~0.04% for the four target parameters: hydrogen, humidity, temperature and salinity. Moreover, a uniform solution was customized to divide the cross-sensitivity between temperature and other target parameters. It is expected that this scheme will be capable of handling thousands of multi-parameter sensors in a single fiber.

  10. Prognostic value of metabolic tumor volume as measured by fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography in nasopharyngeal carcinoma.

    Science.gov (United States)

    Yoon, Young-Ho; Lee, Seok-Hwan; Hong, Sung-Lyong; Kim, Seong-Jang; Roh, Hwan-Jung; Cho, Kyu-Sup

    2014-10-01

    The prognostic value of the tumor burden characterized by the metabolic tumor volume (MTV) remains under investigation in nasopharyngeal carcinoma (NPC). The purpose of this study was to evaluate the prognostic value of the maximum standardized uptake value (SUVmax ) and MTV according to metabolic volume threshold as measured by positron emission tomography (PET)/computed tomography (CT), and other clinical factors, in patients with NPC. This study was a retrospective chart review. We evaluated the association of SUVmax , MTV2.5 , MTV3.0 , and other clinical factors with overall survival (OS) using Kaplan-Meier and Cox regression models. (MTV2.5 and MTV3.0 are the volume of hypermetabolic tissue within the regions of gross tumor volumes with a SUV value greater than the threshold values of 2.5 and 3.0, respectively.) Higher MTV2.5 of 31.45 cm(3) and MTV3.0 of 23.01 cm(3) were associated with an increased risk of death (hazard ratio [HR] = 5.028; p = 0.029), although no significant relationship was found between SUVmax and OS. Interestingly, MTV3.0 was associated with OS in both the differentiated and undifferentiated groups, although MTV2.5 was only associated with OS in the undifferentiated group. Among the clinical parameters, only radiotherapy was associated with longer OS (HR = 12.124; p < 0.001). The MTV and radiotherapy could be prognostic values associated with OS. Particularly, MTV2.5 and MTV3.0 might be valuable metabolic parameters for predicting long-term survival in patients with NPC. Furthermore, MTV3.0 may be more useful because it can be applied irrespective of pathologic subtype. © 2014 ARS-AAOA, LLC.

  11. Measurements of the Z boson resonance parameters at SLC [SLAC Linear Collider

    International Nuclear Information System (INIS)

    Hearty, C.

    1989-07-01

    This paper presents the measurement by the Mark II experiment at the SLAC Linear Collider of the parameters of the Z boson resonance. The results are updated from those presented at the SLAC Summer Institute to include all data presented in the most recent Mark II publication, consisting of 19 nb -1 of data at ten different center-of-mass energies between 89.2 and 93.0 GeV. The resonance parameters are extracted by measuring the Z production cross section at a series of center-of-mass energies (scan points) near the Z peak, then fitting these data with the theoretical cross section. The four major aspects of the analysis are the determination at each scan point of the center-of-mass energy (E), the integrated luminosity, the number of Z decays and the expected cross section as a function of the resonance parameters, such as mass and width. I will discuss each of these steps in turn, after a brief description of the Mark II detector, then conclude with the results of the analysis. 7 refs., 9 figs., 3 tabs

  12. Non-invasive technique to measure biogeochemical parameters (pH and O2) in a microenvironment: Design and applications

    Science.gov (United States)

    Li, Biting; Seliman, Ayman; Pales, Ashley; Liang, Weizhen; Sams, Allison; Darnault, Christophe; Devol, Timothy

    2017-04-01

    The primary objectives of this research are to do the pH and O2 sensor foils calibration and then to test them in applications. Potentially, this project can be utilized to monitor the fate and transport of radionuclides in porous media. The information for physical and chemical parameters (e.g. pH and O2) is crucial to know when determining contaminants' behavior and transport in the environment. As a non-invasive method, optical imaging technique using a DSLR camera could capture data on the foil when it fluoresces, and gives a high temporal and spatial resolution during the experimental period. The calibration procedures were done in cuvettes in a row. The preliminary experiments could measure pH value in the range from 4.5 to 7.5, and O2 concentration from 0 mg/L to 20.74 mg/L. Applications of sensor foils have involved nano zero valent and acid rain experiments in order to obtain a gradient of parameter changes.

  13. Length expectation values in quantum Regge calculus

    International Nuclear Information System (INIS)

    Khatsymovsky, V.M.

    2004-01-01

    Regge calculus configuration superspace can be embedded into a more general superspace where the length of any edge is defined ambiguously depending on the 4-tetrahedron containing the edge. Moreover, the latter superspace can be extended further so that even edge lengths in each the 4-tetrahedron are not defined, only area tensors of the 2-faces in it are. We make use of our previous result concerning quantization of the area tensor Regge calculus which gives finite expectation values for areas. Also our result is used showing that quantum measure in the Regge calculus can be uniquely fixed once we know quantum measure on (the space of the functionals on) the superspace of the theory with ambiguously defined edge lengths. We find that in this framework quantization of the usual Regge calculus is defined up to a parameter. The theory may possess nonzero (of the order of Planck scale) or zero length expectation values depending on whether this parameter is larger or smaller than a certain value. Vanishing length expectation values means that the theory is becoming continuous, here dynamically in the originally discrete framework

  14. Comparison of 15N- and 13C-determined parameters of mobility in melittin

    International Nuclear Information System (INIS)

    Zhu Lingyang; Prendergast, Franklyn G.; Kemple, Marvin D.

    1998-01-01

    Backbone and tryptophan side-chain mobilities in the 26-residue, cytolytic peptide melittin (MLT) were investigated by 15 N and 13 C NMR. Specifically, inverse-detected 15 N T 1 and steady-state NOE measurements were made at 30 and 51 MHz on MLT at 22 deg. C enriched with 15 N at six amide positions and in the Trp 19 side chain. Both the disordered MLT monomer (1.2 mM peptide at pH 3.6 in neat water) and α-helical MLT tetramer (4.0 mM peptide at pH 5.2 in 150 mM phosphate buffer) were examined. The relaxation data were analyzed in terms of the Lipari and Szabo model-free formalism with three parameters: τ m , the correlation time for the overall rotation; S 2 , a site-specific order parameter which is a measure of the amplitude of the internal motion; and τ e , a local, effective correlation time of the internal motion. A comparison was made of motional parameters from the 15 N measurements and from 13 C measurements on MLT, the latter having been made here and previously [Kemple et al. (1997) Biochemistry, 36, 1678-1688]. τ m and τ e values were consistent from data on the two nuclei. In the MLT monomer, S 2 values for the backbone N-H and Cα-H vectors in the same residue were similar in value but in the tetramer the N-H order parameters were about 0.2 units larger than the Cα-H order parameters. The Trp side-chain N-H and C-H order parameters, and τ e values were generally similar in both the monomer and tetramer. Implications of these results regarding the dynamics of MLT are examined

  15. Electron density values of various human tissues: in vitro Compton scatter measurements and calculated ranges

    International Nuclear Information System (INIS)

    Shrimpton, P.C.

    1981-01-01

    Accurate direct measurements of electron density have been performed on specimens from 10 different tissue types of the human body, representing the major organs, using a Compton scatter technique. As a supplement to these experimental values, calculations have been carried out to determine the electron densities expected for these tissue types. The densities observed are in good agreement with the broad ranges deduced from the basic data previously published. The results of both the in vitro sample measurements and the approximate calculations indicate that the electron density of most normal healthy soft tissue can be expected to fall within the fairly restricted range of +- 5% around 3.4 X 10 23 electrons per cm 3 . The obvious exception to this generalisation is the result for lung tissue, which falls considerably below this range owing to the high air content inherent in its construction. In view of such an overall limited variation with little difference between tissues, it would appear that electron density alone is likely to be a rather poor clinical parameter for tissue analysis, with high accuracy and precision being essential in any in vivo Compton measurements for imaging or diagnosis on specific organs. (author)

  16. Risk factor meta-analysis and Bayesian estimation of genetic parameters and breeding values for hypersensibility to cutaneous habronematidosis in donkeys.

    Science.gov (United States)

    Navas González, Francisco Javier; Jordana Vidal, Jordi; Camacho Vallejo, María Esperanza; León Jurado, Jose Manuel; de la Haba Giraldo, Manuel Rafael; Barba Capote, Cecilio; Delgado Bermejo, Juan Vicente

    2018-03-15

    Cutaneous habronematidosis (CH) is a highly prevalent seasonally recurrent skin disease that affects donkeys as a result from the action of spirurid stomach worm larvae. Carrier flies mistakenly deposit these larvae on previous skin lesions or on the moisture of natural orifices, causing distress and inflicting relapsing wounds to the animals. First, we carried out a meta-analysis of the predisposing factors that could condition the development of CH in Andalusian donkeys. Second, basing on the empirical existence of an inter and intrafamilial variation previously addressed by owners, we isolated the genetic background behind the hypersensibility to this parasitological disease. To this aim, we designed a Bayesian linear model (BLM) to estimate the breeding values and genetic parameters for the hypersensibility to CH as a way to infer the potential selection suitability of this trait, seeking the improvement of donkey conservation programs. We studied the historical record of the cases of CH of 765 donkeys from 1984 to 2017. Fixed effects included birth year, birth season, sex, farm/owner, and husbandry system. Age was included as a linear and quadratic covariate. Although the effects of birth season and birth year were statistically non-significant (P > 0.05), their respective interactions with sex and farm/owner were statistically significant (P < 0.01), what translated into an increase of 40.5% in the specificity and of 0.6% of the sensibility of the model designed, when such interactions were included. Our BLM reported highly accurate genetic parameters as suggested by the low error of around 0.005, and the 95% credible interval for the heritability of ±0.0012. The CH hypersensibility heritability was 0.0346. The value of 0.1232 for additive genetic variance addresses a relatively low genetic variation in the Andalusian donkey breed. Our results suggest that farms managed under extensive husbandry conditions are the most protective ones against

  17. Software measurement standards for areal surface texture parameters: part 2—comparison of software

    International Nuclear Information System (INIS)

    Harris, P M; Smith, I M; Giusca, C; Leach, R K; Wang, C

    2012-01-01

    A companion paper in this issue describes reference software for the evaluation of areal surface texture parameters, focusing on the definitions of the parameters and giving details of the numerical algorithms employed in the software to implement those definitions. The reference software is used as a benchmark against which software in a measuring instrument can be compared. A data set is used as input to both the software under test and the reference software, and the results delivered by the software under test are compared with those provided by the reference software. This paper presents a comparison of the results returned by the reference software with those reported by proprietary software for surface texture measurement. Differences between the results can be used to identify where algorithms and software for evaluating the parameters differ. They might also be helpful in identifying where parameters are not sufficiently well-defined in standards. (paper)

  18. Determination of material parameters by comparison of 3D simulations and 3D experiments

    DEFF Research Database (Denmark)

    Zhang, Jin

    microstructure and the measured microstructure in a global manner. The proposed method is demonstrated on a simple case to fit two material parameters: the liquid diffusion coefficient and the capillary length of a hypoeutectic Al-Cu alloy, and a complicated case to fit hundreds of material parameters......: the reduced grain boundary mobilities of pure iron. Results show that the proposed method is capable of providing reliable measurements of material parameters that are difficult to measure in traditional ways and can determine many - possibly all relevant - values of material parameters simultaneously...

  19. Value-based performance measures for Hanford Tank Waste Remedition System (TWRS) Program

    International Nuclear Information System (INIS)

    Keeney, R.L.; von Winterfeldt, D.

    1996-01-01

    The Tank Waste Remediation Systems (TWRS) Program is responsible for the safe storage, retrieval, treatment, and preparation for disposal of high-level waste currently stored in underground storage tanks at the Hanford site in Richland. The TWRS program has adopted a logical approach to decision making that is based on systems engineering and decision analysis (Westinghouse Hanford Company, 1995). This approach involves the explicit consideration of stakeholder values and an evaluation of the TWRS alternatives in terms of these values. Such evaluations need to be consistent across decisions. Thus, an effort was undertaken to develop a consistent, quantifiable set of measures that can be used by TVVRS to assess alternatives against the stakeholder values. The measures developed also met two additional requirements: 1) the number of measure should be relatively small; and 2) performance with respect to the measures should be relatively easy to estimate

  20. Determination of toroidal equilibrium parameters from magnetic probe measurements

    International Nuclear Information System (INIS)

    Brynolf, J.; Eriksson, H.G.; Persson, H.; Hellblom, G.

    1992-12-01

    A method has been developed by which the poloidal flux function in the vacuum region between the plasma and the external conductors (and the iron core) can be deduced from external magnetic field measurements. The plasma is in equilibrium and the solution is restricted to plasmas without irregularities. The poloidal field components Bθ and B r are measured at different poloidal positions outside the liner and modelled by truncated Fourier series. The Grad-Shafranov equation in the vacuum region is then solved with these modelled values of Bθ and B r as boundary conditions. (authors)