WorldWideScience

Sample records for measured mmvf levels

  1. Man-made vitreous fiber produced from incinerator ash using the thermal plasma technique and application as reinforcement in concrete.

    Science.gov (United States)

    Yang, Sheng-Fu; Wang, To-Mai; Lee, Wen-Cheng; Sun, Kin-Seng; Tzeng, Chin-Ching

    2010-10-15

    This study proposes using thermal plasma technology to treat municipal solid waste incinerator ashes. A feasible fiberization method was developed and applied to produce man-made vitreous fiber (MMVF) from plasma vitrified slag. MMVF were obtained through directly blending the oxide melt stream with high velocity compressed air. The basic technological characteristics of MMVF, including morphology, diameter, shot content, length and chemical resistance, are described in this work. Laboratory experiments were conducted on the fiber-reinforced concrete. The effects of fibrous content on compressive strength and flexural strength are presented. The experimental results showed the proper additive of MMVF in concrete can enhance its mechanical properties. MMVF products produced from incinerator ashes treated with the thermal plasma technique have great potential for reinforcement in concrete. 2010 Elsevier B.V. All rights reserved.

  2. Biological durability and oxidative potential of man-made vitreous fibres as compared to crocidolite asbestos fibres

    Energy Technology Data Exchange (ETDEWEB)

    Hippeli, S.; Dornisch, K.; Elstner, E.F. [Lehrstuhl fuer Phytopathologie, Technische Univ. Muenchen-Weihenstephan, Freising-Weihenstephan (Germany); Wiethege, T.; Mueller, K.M. [Berufsgenossenschaftliche Kliniken Bergmannsheil, Universitaetsklinik, Inst. fuer Pathologie, Bochum (Germany); Gillissen, A. [Medizinische Universitaetsklinik und Poliklinik II, Kardiologie, Pneumologie, Bonn (Germany)

    2001-08-01

    In this study we investigated relationships between redox properties and biodurability of crocidolite asbestos fibres and three different man-made vitreous fibres (MMVF): traditional stone wool fibres (MMVF 21), glass fibres (MMVF 11) and refractory ceramic fibres (RCF). Each fibre type was incubated up to 22 weeks in four different incubation media: gamble solution (GS) pH 5.0 and pH 7.4, representing blood plasma without proteins, and surfactant-like solution (SLS) pH 5.0 and pH 7.4. During incubation time aliquots of incubation mixtures were removed and analysed in a biochemical model reaction, mimicking activated phagocytes. In addition, changes of fibre morphology and chemical composition were examined using SEM- and EDX-technology. In the presence of crocidolite asbestos fibres and MMVF 21 the formation of OH-radicals according to the Haber-Weiss sequence could be demonstrated, whereas MMVF 11 and RCF showed no reactivity. Crocidolite asbestos fibres exhibited a significant higher activity compared with the stone wool fibres at the onset of incubation. The oxidative capacities of these fibre types were shown to depend on both specific surface area and iron content. The oxidative potentials of crocidolite asbestos fibres as well as MMVF 21 were not constant during incubation over several weeks in each incubation medium. The reactivities showed sinoidal curves including reactivities much higher than those at the onset of incubation time. These irregular changes of oxidative capacity may be explained by changes of the redox state of fibre surface-complexed iron. Furthermore our results showed clear differences between incubation of fibres in GS and SLS, respectively, indicating that phospholipids play an important part in fibre dissolution behaviour and oxidative reactivity. (orig.)

  3. Low-level Radioactivity Measurements

    International Nuclear Information System (INIS)

    Churtgen, C.

    2007-01-01

    The low-level radioactivity measurements service performs measurements of alpha or beta emitters on various types of low-radioactivity samples (biological and environmental) from internal and external clients. to maintain and develop techniques concerning the measurement of low-level radioactivity of alpha and beta emitting radionuclides in environmental or biological samples; to measure these samples by means of low-background counters (liquid scintillators, proportional counters, ZnS counters and alpha-spectrometers); to support and advise the nuclear and non-nuclear industry on problems of radioactive contamination or low level radioactivity measurements; to maintain the quality assurance system according to the ISO17025 standard for which we obtained the Beltest accreditation in 1998; to assess the internal dose from occupational intakes of radionuclides for workers of the nuclear industry;

  4. Low-level Radioactivity Measurements

    International Nuclear Information System (INIS)

    Hurtgen, C.

    2002-01-01

    The objectives of the research performed in the area of low-level radioactivity measurements are (1) to maintain and develop techniques for the measurement of low-level environmental and biological samples, (2) to measure these samples by means of low-background counters (liquid scintillators, proportional counters, ZnS counters, alpha spectrometry), (3) to support and advise the nuclear and non-nuclear industry on problems of radioactive contamination and low-level radioactivity measurements; (4) to maintain and improve the quality assurance system according to the ISO17025 standard; and (5) to assess the internal dose from occupational intakes of radionuclides of workers of the nuclear industry. Progress and achievements in these areas in 2001 are reported

  5. Low-level Radioactivity Measurements

    International Nuclear Information System (INIS)

    Hurtgen, C.

    2001-01-01

    The objectives of the research performed in the area of low-level radioactivity measurements are (1) to maintain and develop techniques for the measurement of low-level environmental and biological samples, (2) to measure these samples by means of low-background counters (liquid scintillators, proportional counters, ZnS counters, alpha spectrometry), (3) to support and advice the nuclear and non-nuclear industry in matters concerning radioactive contamination and/or low-level radioactivity measurements; (4) to maintain the quality assurance system according to the EN45001/ISO17025 standard; and (5) to assess the internal dose from occupational intakes of radionuclides of workers of the nuclear industry. Progress and achievements in these areas in 2000 are reported

  6. Liquid level measurement in high level nuclear waste slurries

    International Nuclear Information System (INIS)

    Weeks, G.E.; Heckendorn, F.M.; Postles, R.L.

    1990-01-01

    Accurate liquid level measurement has been a difficult problem to solve for the Defense Waste Processing Facility (DWPF). The nuclear waste sludge tends to plug or degrade most commercially available liquid-level measurement sensors. A liquid-level measurement system that meets demanding accuracy requirements for the DWPF has been developed. The system uses a pneumatic 1:1 pressure repeater as a sensor and a computerized error correction system. 2 figs

  7. Nuclear systems of level measurement

    International Nuclear Information System (INIS)

    Lara, A.J.; Cabrera, M.J.

    1992-01-01

    In the industry there are processes in which is necessary to maintain the products level controlled which are handled for their transformation. The majority of such processes and by the operation conditions, they do not admit measure systems of level of invasive type then the application of nuclear techniques for level measurement results a big aid in these cases, since all the system installation is situated beyond frontiers of vessels that contain the product for measuring. In the Department of Nuclear Technology Applications of Mexican Petroleum Institute was developed a level measurement system by gamma rays transmission which operates in the Low Density Polyethylene plant of Petrochemical Complex Escolin at Poza Rica, Veracruz, Mexico. (Author)

  8. Measurement uncertainty in broadband radiofrequency radiation level measurements

    Directory of Open Access Journals (Sweden)

    Vulević Branislav D.

    2014-01-01

    Full Text Available For the evaluation of measurement uncertainty in the measurement of broadband radio frequency radiation, in this paper we propose a new approach based on the experience of the authors of the paper with measurements of radiofrequency electric field levels conducted in residential areas of Belgrade and over 35 municipalities in Serbia. The main objective of the paper is to present practical solutions in the evaluation of broadband measurement uncertainty for the in-situ RF radiation levels. [Projekat Ministarstva nauke Republike Srbije, br. III43009

  9. Liquid metal level measurement

    International Nuclear Information System (INIS)

    Hale, J.C.; Leyland, K.S.

    1982-01-01

    A liquid metal level indicator is described which can be used to measure, in a stainless steel tank, the level of a nuclear reactor coolant such as sodium. The instrument, which is based on the eddy current induction effect, gives readings over substantially the full depth of the tank and indicates the sense of change of level. (U.K.)

  10. Method for steam generator water level measurement

    International Nuclear Information System (INIS)

    Srinivasan, J.S.

    1991-01-01

    This paper describes a nuclear power plant, a method of controlling the steam generator water level, wherein the steam generator has an upper level tap corresponding to an upper level, a lower level, a riser positioned between the lower and upper taps, and level sensor means for indicating water level between a first range limit and a second range limit, the sensor means being connected to at least the lower tap. It comprises: calculating a measure of velocity head at about the lower level tap; calculating a measure of full water level as the upper level less the measure of velocity head; calibrating the level sensor means to provide an output at the first limit corresponding to an input thereto representative of the measure of full level; calculating a high level setpoint equal to the level of the riser less a bias amount which is a function of the position of the riser relative to the span between the taps; and controlling the water level when the sensor means indicates that the high level setpoint has been reached

  11. Water level measurement uncertainty during BWR instability

    International Nuclear Information System (INIS)

    Torok, R.C.; Derbidge, T.C.; Healzer, J.M.

    1994-01-01

    This paper addresses the performance of the water-level measurement system in a boiling water reactor (BWR) during severe instability oscillations which, under some circumstances, can occur during an anticipated transient without SCRAM (ATWS). Test data from a prototypical mock-up of the water-level measurement system was used to refine and calibrate a water-level measurement system model. The model was then used to predict level measurement system response, using as boundary conditions vessel pressures calculated by ppercase RETRAN for an ATWS/instability event.The results of the study indicate that rapid pressure changes in the reactor pressure vessel which cause oscillations in downcomer water level, coupled with differences in instrument line lengths, can produce errors in the sensed water level. Using nominal parameters for the measurement system components, a severe instability transient which produced a 0.2 m peak-to-minimum water-level oscillation in the vessel downcomer was predicted to produce pressure difference equivalent to a 0.7 m level oscillation at the input to the differential pressure transmitter, 0.5 m oscillation at the output of the transmitter, and an oscillation of 0.3 m on the water-level indicator in the control room. The level measurement system error, caused by downcomer water-level oscillations and instrument line length differential, is mitigated by damping both in the differential pressure transmitter used to infer level and in the control room display instrument. ((orig.))

  12. Method of measuring reactor water level

    International Nuclear Information System (INIS)

    Shinohara, Kaoru.

    1979-01-01

    Purpose: To provide a water level measuring system so that a reactor water level detecting signal can be corrected in correspondence to a recirculation flow, thereby to carry out a correct water level detection in a wide range of the reactor. Method: According to the operation record of a precursor reactor, the ratio Δh of the lowering of the water level due to the recirculation flow is lowered in proportion to the ratiowith respect to the rated differential pressure of the recirculation flow. Accordingly, the flow of recirculation pump is measured by an elbow differential pressure generator utilizing an elbow of a pipe, and the measured value is multiplied by a gain by a ratio setter, and therefter, an addition computation is carried out by an adder for correcting the signal from a water level detector. When the signal from the water level detector is corrected in this manner, the influence of the lowering of the water level due to the recirculation flow can be removed, and an interlocker predetermined in the defined water level can be actuated, thus the influence of the dynamic pressure due to the recirculation flow acting on the instrumental pipe line detecting the reactor water level can be removed effectively. (Yoshino, Y.)

  13. Dissolution of short and long rockwool and glasswool fibers by macrophages in flowthrough cell culture.

    Science.gov (United States)

    Luoto, K; Holopainen, M; Kangas, J; Kalliokoski, P; Savolainen, K

    1998-07-01

    Dissolution of MMVF (man-made vitreous fibers) by macrophages has previously been studied utilizing cell cultures in wells. A new, more dynamic method has been developed to explore the effects of macrophages on MMVF dissolution. In this method, the culture medium flows through a membrane on which the macrophages and fibers are placed. The dissolution of short and long rockwool and glasswool fibers was investigated in the present study by macrophages by assessing the dissolution of Si (silicon), Fe (iron), and Al (aluminium) from the fibers. Dissolution of these elements usually increased as a function of time. Generally, the dissolution of elements from the fibers in the flowthrough culture exceeded that observed with the culture in wells system. The dissolution of glasswool fibers was greater in medium than in cell culture, whereas the opposite was true for rockwool fibers. Dissolution of Si was greater from glasswool than from rockwool fibers, while the opposite was true for Fe and Al. Macrophages that had phagocytized fibers in flowthrough culture contained Si, and there were also precipitations with Si in the samples. The fibers in the flowthrough culture also exhibited surface changes such as breakings, pittings, etching, and peeling. The short rockwool fibers tended to fracture more than short glasswool fibers, while long glasswool fibers were more extensively broken than short glasswool fibers. The results with this new, dynamic, flowthrough culture method with macrophages demonstrate that this method provides valuable information on the abilities of macrophages to dissolve MMVF leading to subsequent morphological changes of fibers.

  14. Measuring healthcare productivity - from unit to system level.

    Science.gov (United States)

    Kämäräinen, Vesa Johannes; Peltokorpi, Antti; Torkki, Paulus; Tallbacka, Kaj

    2016-04-18

    Purpose - Healthcare productivity is a growing issue in most Western countries where healthcare expenditure is rapidly increasing. Therefore, accurate productivity metrics are essential to avoid sub-optimization within a healthcare system. The purpose of this paper is to focus on healthcare production system productivity measurement. Design/methodology/approach - Traditionally, healthcare productivity has been studied and measured independently at the unit, organization and system level. Suggesting that productivity measurement should be done in different levels, while simultaneously linking productivity measurement to incentives, this study presents the challenges of productivity measurement at the different levels. The study introduces different methods to measure productivity in healthcare. In addition, it provides background information on the methods used to measure productivity and the parameters used in these methods. A pilot investigation of productivity measurement is used to illustrate the challenges of measurement, to test the developed measures and to prove the practical information for managers. Findings - The study introduces different approaches and methods to measure productivity in healthcare. Practical implications - A pilot investigation of productivity measurement is used to illustrate the challenges of measurement, to test the developed measures and to prove the practical benefits for managers. Originality/value - The authors focus on the measurement of the whole healthcare production system and try to avoid sub-optimization. Additionally considering an individual patient approach, productivity measurement is examined at the unit level, the organizational level and the system level.

  15. Market survey of level measurement equipment

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    In a market survey of level measurement equipment from 42 manufacturers, which is based on different principles of measurement and which is used for different applications, the data of the various manufacturers is compiled. (orig./HP) [de

  16. Sound level measurements using smartphone "apps": Useful or inaccurate?

    Directory of Open Access Journals (Sweden)

    Daniel R Nast

    2014-01-01

    Full Text Available Many recreational activities are accompanied by loud concurrent sounds and decisions regarding the hearing hazards associated with these activities depend on accurate sound measurements. Sound level meters (SLMs are designed for this purpose, but these are technical instruments that are not typically available in recreational settings and require training to use properly. Mobile technology has made such sound level measurements more feasible for even inexperienced users. Here, we assessed the accuracy of sound level measurements made using five mobile phone applications or "apps" on an Apple iPhone 4S, one of the most widely used mobile phones. Accuracy was assessed by comparing application-based measurements to measurements made using a calibrated SLM. Whereas most apps erred by reporting higher sound levels, one application measured levels within 5 dB of a calibrated SLM across all frequencies tested.

  17. 45 CFR 305.40 - Penalty performance measures and levels.

    Science.gov (United States)

    2010-10-01

    ... HUMAN SERVICES PROGRAM PERFORMANCE MEASURES, STANDARDS, FINANCIAL INCENTIVES, AND PENALTIES § 305.40 Penalty performance measures and levels. (a) There are three performance measures for which States must... 45 Public Welfare 2 2010-10-01 2010-10-01 false Penalty performance measures and levels. 305.40...

  18. Measurement of Heme Synthesis Levels in Mammalian Cells.

    Science.gov (United States)

    Hooda, Jagmohan; Alam, Maksudul; Zhang, Li

    2015-07-09

    Heme serves as the prosthetic group for a wide variety of proteins known as hemoproteins, such as hemoglobin, myoglobin and cytochromes. It is involved in various molecular and cellular processes such as gene transcription, translation, cell differentiation and cell proliferation. The biosynthesis levels of heme vary across different tissues and cell types and is altered in diseased conditions such as anemia, neuropathy and cancer. This technique uses [4-(14)C] 5-aminolevulinic acid ([(14)C] 5-ALA), one of the early precursors in the heme biosynthesis pathway to measure the levels of heme synthesis in mammalian cells. This assay involves incubation of cells with [(14)C] 5-ALA followed by extraction of heme and measurement of the radioactivity incorporated into heme. This procedure is accurate and quick. This method measures the relative levels of heme biosynthesis rather than the total heme content. To demonstrate the use of this technique the levels of heme biosynthesis were measured in several mammalian cell lines.

  19. Industrial level measurement techniques - a review

    International Nuclear Information System (INIS)

    Schaudel, D.E.

    1984-01-01

    The outlined methods of industrial level measurement technique are nowadays in current use. In correspondence with the technical evolution the mechanical techniques are mentioned first, followed by a description of the more modern electronic methods. These measurement methods comply especially to the requirements of computer aided process guiding systems, i.e. compatibility of signals, self-checking and reliability. (orig.) [de

  20. Application of neutron backscatter techniques to level measurement problems

    International Nuclear Information System (INIS)

    Leonardi-Cattolica, A.M.; McMillan, D.H.; Telfer, A.; Griffin, L.H.; Hunt, R.H.

    1982-01-01

    We have designed and built portable level detectors and fixed level monitors based on neutron scattering and detection principles. The main components of these devices, which we call neutron backscatter gauges, are a neutron emitting radioisotope, a neutron detector, and a ratemeter. The gauge is a good detector for hydrogen but is much less sensitive to most other materials. This allows level measurements of hydrogen bearing materials, such as hydrocarbons, to be made through the walls of metal vessels. Measurements can be made conveniently through steel walls which are a few inches thick. We have used neutron backscatter gauges in a wide variety of level measurement applications encountered in the petrochemical industry. In a number of cases, the neutron techniques have proven to be superior to conventional level measurement methods, including gamma ray methods

  1. Lifetime measurements of excited Co I levels

    CERN Document Server

    Klotz, W D; Gobel, L H

    1977-01-01

    In the region of 3500 AA the lifetimes of eight excited Cobalt I levels have been measured by means of the zero field level crossing method. The measured lifetimes belong to the odd configurations 3d/sup 7/4s4p and 3d/sup 8/4p and are of the accuracy of about 5%. The hyperfine structure of levels with I not=J has to be taken into account in evaluating lifetimes from level crossing data, because the nuclear spin of the natural isotope /sup 59/Co is I=7/2. Therefore the influence of the line profile of the exciting resonance lines on the lifetimes has been investigated. The results are compared with those of other authors. Furthermore absolute oscillator strengths were calculated with known branching ratios and a new absolute scale has been established. (23 refs).

  2. Wireless Fluid-Level Measurement System Equips Boat Owners

    Science.gov (United States)

    2008-01-01

    While developing a measurement acquisition system to be used to retrofit aging aircraft with vehicle health monitoring capabilities, Langley Research Center developed an innovative wireless fluid-level measurement system. The NASA technology was of interest to Tidewater Sensors LLC, of Newport News, Virginia, because of its many advantages over conventional fuel management systems, including its ability to provide an accurate measurement of volume while a boat is experiencing any rocking motion due to waves or people moving about on the boat. These advantages led the company to license this novel fluid-level measurement system from NASA for marine applications.

  3. Evaluation of a method to measure long term cortisol levels.

    Science.gov (United States)

    Manenschijn, Laura; Koper, Jan W; Lamberts, Steven W J; van Rossum, Elisabeth F C

    2011-01-01

    Elevated levels of cortisol are known to induce various symptoms and diseases, e.g. abdominal obesity, type 2 diabetes, osteoporosis and cardiovascular disease. Measuring serum, saliva and urine cortisol is limited to one time point. Measurement of cortisol in scalp hair is a recently developed method to measure long term cortisol levels. The aim of this study was to investigate whether hair cortisol is a feasible parameter to measure cortisol exposure. We collected hair samples of 195 healthy individuals, 9 hypercortisolemic and one hypocortisolemic patient and measured hair cortisol levels. Cortisol was extracted from scalp hair using methanol and cortisol levels were measured using a salivary ELISA kit. Measurement of waist and hip circumferences and blood pressure was performed in 46 healthy subjects. We found a positive correlation between hair cortisol and both waist circumference (r=0.392, p=0.007) and waist-to-hip ratio (WHR) (r=0.425, p=0.003). No correlations were found between hair cortisol levels and BMI, blood pressure or age. There was no decline in cortisol levels in six consecutive hair segments. Hair cortisol levels were elevated in patients with known hypercortisolism (pcortisol was positively correlated with WHR, suggesting that hair cortisol reflects cortisol exposure at tissue level, which was also supported by elevated hair cortisol levels in hypercortisolemic patients and concordance between hair cortisol levels and clinical disease course. Cortisol levels in hair are slightly influenced by hair treatment but not by natural hair colour, use of hair products, gender or age. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Precise mean sea level measurements using the Global Positioning System

    Science.gov (United States)

    Kelecy, Thomas M.; Born, George H.; Parke, Michael E.; Rocken, Christian

    1994-01-01

    This paper describes the results of a sea level measurement test conducted off La Jolla, California, in November of 1991. The purpose of this test was to determine accurate sea level measurements using a Global Positioning System (GPS) equipped buoy. These measurements were intended to be used as the sea level component for calibration of the ERS 1 satellite altimeter. Measurements were collected on November 25 and 28 when the ERS 1 satellite overflew the calibration area. Two different types of buoys were used. A waverider design was used on November 25 and a spar design on November 28. This provided the opportunity to examine how dynamic effects of the measurement platform might affect the sea level accuracy. The two buoys were deployed at locations approximately 1.2 km apart and about 15 km west of a reference GPS receiver located on the rooftop of the Institute of Geophysics and Planetary Physics at the Scripps Institute of Oceanography. GPS solutions were computed for 45 minutes on each day and used to produce two sea level time series. An estimate of the mean sea level at both locations was computed by subtracting tide gage data collected at the Scripps Pier from the GPS-determined sea level measurements and then filtering out the high-frequency components due to waves and buoy dynamics. In both cases the GPS estimate differed from Rapp's mean altimetric surface by 0.06 m. Thus, the gradient in the GPS measurements matched the gradient in Rapp's surface. These results suggest that accurate sea level can be determined using GPS on widely differing platforms as long as care is taken to determine the height of the GPS antenna phase center above water level. Application areas include measurement of absolute sea level, of temporal variations in sea level, and of sea level gradients (dominantly the geoid). Specific applications would include ocean altimeter calibration, monitoring of sea level in remote regions, and regional experiments requiring spatial and

  5. CMS High Level Trigger Timing Measurements

    International Nuclear Information System (INIS)

    Richardson, Clint

    2015-01-01

    The two-level trigger system employed by CMS consists of the Level 1 (L1) Trigger, which is implemented using custom-built electronics, and the High Level Trigger (HLT), a farm of commercial CPUs running a streamlined version of the offline CMS reconstruction software. The operational L1 output rate of 100 kHz, together with the number of CPUs in the HLT farm, imposes a fundamental constraint on the amount of time available for the HLT to process events. Exceeding this limit impacts the experiment's ability to collect data efficiently. Hence, there is a critical need to characterize the performance of the HLT farm as well as the algorithms run prior to start up in order to ensure optimal data taking. Additional complications arise from the fact that the HLT farm consists of multiple generations of hardware and there can be subtleties in machine performance. We present our methods of measuring the timing performance of the CMS HLT, including the challenges of making such measurements. Results for the performance of various Intel Xeon architectures from 2009-2014 and different data taking scenarios are also presented. (paper)

  6. Automatic Measurement of Low Level Contamination on Concrete Surfaces

    International Nuclear Information System (INIS)

    Tachibana, M.; Itoh, H.; Shimada, T.; Yanagihara, S.

    2002-01-01

    Automatic measurement of radioactivity is necessary for considering cost effectiveness in final radiological survey of building structures in decommissioning nuclear facilities. The RAPID (radiation measuring pilot device for surface contamination) was developed to be applied to automatic measurement of low level contamination on concrete surfaces. The RAPID has a capability to measure contamination with detection limit of 0.14 Bq/cm2 for 60Co in 30 seconds of measurement time and its efficiency is evaluated to be 5 m2/h in a normal measurement option. It was confirmed that low level contamination on concrete surfaces could be surveyed by the RAPID efficiently compared with direct measurement by workers through its actual application

  7. Investigation of Leveling Equipment for High Precision Measurements

    International Nuclear Information System (INIS)

    Gassner, G.

    2007-01-01

    At SLAC (Stanford Linear Accelerator Center) a fully automated vertical comparator for the calibration of digital levels and invar staffs was developed by the Metrology Department in cooperation with the Institute of Engineering Geodesy and Measurement Systems at the Graz University of Technology. This vertical comparator is the first in the US. With the vertical comparator it is possible to perform system calibration and CCD camera measurements of rods. System calibration uses the height readings of the digital level at different positions of the rod and compares them with the reference readings obtained by the interferometer. In the case of CCD camera measurements, the positions of the edges in the image is determined and again compared with the interferometer readings. This document gives an overview of the current set-up of the SLAC vertical comparator and experimental results of critical applications including measurements at the end sections of the rod, at critical sighting distances, with unfocused optics and under illumination with the digital levels in use at SLAC

  8. Commissioning of the XENON1T liquid level measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Geis, Christopher [Institut fuer Physik, Johannes Gutenberg-Universitaet, Mainz (Germany)

    2016-07-01

    Two-phase xenon time projection chambers (TPCs) have been operated very successfully in direct detection experiments for dark matter. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level needs to be monitored and controlled with sub-millimeter precision. We present the installation, commissioning and first measurement data of two kinds of level meters operated in the XENON1T TPC: short level meters are three-plated capacitors measuring the level of the liquid-gas interface with a measurement range h∼5 mm and a resolution of ΔC/h∼1 pF/mm. The long level meters are cylindrical double-walled capacitors, measuring the overall filling level of the XENON1T TPC at a measurement range of h=1.4 m and a resolution of ΔC/h∼0.1 pF/mm. Further, we present the design and programming of the readout electronic based on the UTI chip by Smartec, which allows to read all six levelmeters simultaneously.

  9. Alpha radioactivity measurement technology with ionized air type measurement. Applicability evaluation to verification of the clearance level

    International Nuclear Information System (INIS)

    Mita, Yutaka; Matsumura, Toshihiro; Yokoyama, Kaoru; Sugitsue, Noritake

    2008-10-01

    The purpose of this test is to evaluate the applicability of the clearance level measuring system by Ionized Air Type Measurement after decontaminated by sulfuric acid sample. In Ningyo-toge Environmental Engineering Center. The equipment and radioactive waste which were contaminated with uranium are generated so much in future dismantling stage. In our plan, some of equipments and radioactive waste are contaminated to a clearance level, and cut down on decommission and disposal expense. This plan needs the alpha-rays measurement technology of the very low level. We think that ionized Air transfer measurement technology is promising as of clearance verification technology. The ionized Air transfer measurement technology applied to the Ionized Air Type Measurement can measure plan radioactivity of a very low level. Moreover, as compared with a direct survey, there is the merit which can be measured in a short time. However ionized Air transfer measurement technology is new technology. Therefore, there is almost no measurement track record. Furthermore, the date about the influence of a background, a detection limit, measurement performance, and reliability is insufficient. So, this measurement test estimated applicability as clearance level verification of an Ionized Air Type Measurement. (author)

  10. Liquid level measurement on coolant pipeline using Raman distributed temperature sensor

    International Nuclear Information System (INIS)

    Kasinathan, M.; Sosamma, S.; Babu Rao, C.; Murali, N.; Jayakumar, T.

    2011-01-01

    Optical fibre based Raman Distributed Temperature Sensor (RDTS) has been widely used for temperature monitoring in oil pipe line, power cable and environmental monitoring. Recently it has gained importance in nuclear reactor owing to its advantages like continuous, distributed temperature monitoring and immunity from electromagnetic interference. It is important to monitor temperature based level measurement in sodium capacities and in coolant pipelines for Fast Breeder Reactor (FBR). This particular application is used for filling and draining sodium in storage tank of sodium circuits of Fast breeder reactor. There are different conventional methods to find out the sodium level in the storage tank of sodium cooled reactors. They are continuous level measurement and discontinuous level measurement. For continuous level measurement, mutual inductance type level probes are used. The disadvantage of using this method is it needs a temperature compensation circuit. For discontinuous level measurement, resistance type discontinuous level probe and mutual inductance type discontinuous level probe are used. In resistance type discontinuous level probe, each level needs a separate probe. To overcome these disadvantages, RDTS is used for level measurement based distributed temperature from optical fibre as sensor. The feasibility of using RDTS for measurement of temperature based level measurement sensor is studied using a specially designed test set-up and using hot water, instead of sodium. The test set-up consist of vertically erected Stainless Steel (SS) pipe of length 2m and diameter 10cm, with provision for filling and draining out the liquid. Bare graded index multimode fibre is laid straight along the length of the of the SS pipe. The SS pipe is filled with hot water at various levels. The hot water in the SS pipe is maintained at constant temperature by insulating the SS pipe. The temperature profile of the hot water at various levels is measured using RDTS. The

  11. Estimation of the terrestrial gamma-ray levels from car-borne measurements

    International Nuclear Information System (INIS)

    Badran, H.M.

    1998-01-01

    A place to place variation of the gamma-radiation has been measured. The terrestrial gamma-ray levels were obtained with a portable Nal(Tl) detector. Gamma-ray levels were measured inside a car for a distance of about 220 km, from Norman up to Tulsa, Oklahoma, USA. Simultaneous measurements have also been carried out outside the vehicle and at distances 1 m and 5 m from the car. A series of data was collected every 1 mile (∼ 1.6 km). The measurements were also repeated different time under different conditions. The measured car-borne levels were correlated with the outdoor equivalent levels at 1 m above flat ground. The result permits a good estimation of the outdoor gamma-ray levels from the car measurements after the correction due to the vehicle shielding

  12. Measurements of sea level off Tikkavanipalem - Coast India

    Digital Repository Service at National Institute of Oceanography (India)

    Joseph, A.; Desai, R.G.P.; Peshwe, V.B.; Desa, E.; VijayKumar, K.; Desa, E.S.; Mehra, P.; Nagvekar, S.

    , and meteorological measurements were also made during this one-year period. These measurements have indicated that the sea level along this coast contains contributions from several classes of motions, principally tidal motions and set-up/set-down motions...

  13. Device to measure level in a steam drum of NPP

    International Nuclear Information System (INIS)

    Vinogradov, Yu.A.

    1988-01-01

    Gravitation-hydrostatic device for measuring coolant level in a steam drum of NPP is described. The device enables to improve the accuracy and sensitivity of measuring coolant level above and below the submerged perforated sheet of the steam drum and decrease the amount of levelling vessels in the unit by 50%. 1 fig

  14. Slow neutron mapping technique for level interface measurement

    Science.gov (United States)

    Zain, R. M.; Ithnin, H.; Razali, A. M.; Yusof, N. H. M.; Mustapha, I.; Yahya, R.; Othman, N.; Rahman, M. F. A.

    2017-01-01

    Modern industrial plant operations often require accurate level measurement of process liquids in production and storage vessels. A variety of advanced level indicators are commercially available to meet the demand, but these may not suit specific need of situations. The neutron backscatter technique is exceptionally useful for occasional and routine determination, particularly in situations such as pressure vessel with wall thickness up to 10 cm, toxic and corrosive chemical in sealed containers, liquid petroleum gas storage vessels. In level measurement, high energy neutrons from 241Am-Be radioactive source are beamed onto a vessel. Fast neutrons are slowed down mostly by collision with hydrogen atoms of material inside the vessel. Parts of thermal neutron are bounced back towards the source. By placing a thermal detector next to the source, these backscatter neutrons can be measured. The number of backscattered neutrons is directly proportional to the concentration of the hydrogen atoms in front of the neutron detector. As the source and detector moved by the matrix around the side of the vessel, interfaces can be determined as long as it involves a change in hydrogen atom concentration. This paper presents the slow neutron mapping technique to indicate level interface of a test vessel.

  15. FJ-2207 measuring instrument detection pipe surface a level of pollution method

    International Nuclear Information System (INIS)

    Wang Jiangong

    2010-01-01

    On the pipe surface contamination were detected α level of pollution is a frequently encountered dose-detection work. Because the pipeline surface arc, while the measuring probe for the plane, which for accurate measurement difficult. In this paper, on the FJ-2207-type pipe surface contamination measuring instrument measuring pollution levels in the α method was studied. Introduced the FJ-2207 measuring instrument detection pipe surface α pollution levels. Studied this measuring instrument on the same sources of surface, plane α level of radioactivity measured differences in the results obtained control of the apparatus when the direct measurement of the surface correction factor, and gives 32-216 specifications commonly used pipe direct measurement of the amendment factor. Convenient method, test results are reliable for the accurate measurement of pipe pollution levels in the surface of α as a reference and learning. (authors)

  16. Relating measurement invariance, cross-level invariance, and multilevel reliability

    OpenAIRE

    Jak, S.; Jorgensen, T.D.

    2017-01-01

    Data often have a nested, multilevel structure, for example when data are collected from children in classrooms. This kind of data complicate the evaluation of reliability and measurement invariance, because several properties can be evaluated at both the individual level and the cluster level, as well as across levels. For example, cross-level invariance implies equal factor loadings across levels, which is needed to give latent variables at the two levels a similar interpretation. Reliabili...

  17. LOWRAD 96. Methods and applications of low-level radioactivity measurements. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Fietz, J [ed.; Forschungszentrum Rossendorf e.V. (FZR), Dresden (Germany)

    1997-03-01

    The newest developments in the field of low-level radioactivity measurements and new applications for existing and low-level measuring facilities are presented. The contributions mostly were devoted to basic physical aspects and applications of low-level counting. Papers on chemical separation and preparation techniques and on low-level radiation dose determinations were also presented. (DG)

  18. Evaluation of the Automatic Density Compensation for Pressurizer Level Measurement

    International Nuclear Information System (INIS)

    Jeong, Insoo; Min, Seohong; Ahn, Myunghoon

    2014-01-01

    When using two transmitters, it is difficult for the operators to identify the correct level of the pressurizer (PZR) upon failure of one of the two transmitters. For this reason, Korean Utility Requirements Document (KURD) requires that the operators to use three independent level indicators. Two hot calibrated transmitters and one cold calibrated transmitter compose PZR level transmitters in APR1400. In this paper, the deviation between cold calibration and hot calibration is evaluated, and the application of compensated PZR level measurement and uncompen-sated PZR level measurement during the normal operation of APR1400 are introduced. The PZR level signals for APR1400 come in three channels. To satisfy the KURD requirements for PZR level measurement, and at the same time to accomplish correction design and implementation, applicability and differences between hot calibration and cold calibration, compensated level and uncompensated level were evaluated as follows: For proper indication of PZR levels under normal operating condition, two of the three transmitters went through hot calibration and the remaining one transmitter went through cold calibration. This was to allow indicating entire regions of PZR regardless of the plant operation modes. For automatic density compensation per KURD requirements, the algorithm of the density compensated PZR level implemented in the DCS controller and PRV logic is adopted as a signal validation method

  19. Elementary study on γ analysis software for low level measurement

    International Nuclear Information System (INIS)

    Ruan Guanglin; Huang Xianguo; Xing Shixiong

    2001-01-01

    The difficulty in using fashion γ analysis software in low level measurement is discussed. The ROI report file of ORTEC operation system has been chosen as interface file to write γ analysis software for low-level measurement. The author gives software flowchart and applied example and discusses the existent problems

  20. Lifetime measurement of the 8s level in francium

    International Nuclear Information System (INIS)

    Gomez, E.; Sprouse, G.D.; Orozco, L.A.; Galvan, A. Perez

    2005-01-01

    We measure the lifetime of the 8s level of 210 Fr atoms on a magneto-optically trapped sample with time-correlated single-photon counting. The 7P 1/2 state serves as the resonant intermediate level for two-step excitation of the 8s level completed with a 1.3-μm laser. Analysis of the fluorescence decay through the 7P 3/2 level gives 53.30±0.44 ns for the 8s level lifetime

  1. Level validity of self-report whole-family measures.

    Science.gov (United States)

    Manders, Willeke A; Cook, William L; Oud, Johan H L; Scholte, Ron H J; Janssens, Jan M A M; De Bruyn, Eric E J

    2007-12-01

    This article introduces an approach to testing the level validity of family assessment instruments (i.e., whether a family instrument measures family functioning at the level of the system it purports to assess). Two parents and 2 adolescents in 69 families rated the warmth in each of their family relationships and in the family as a whole. Family members' ratings of whole-family warmth assessed family functioning not only at the family level (i.e., characteristics of the family as a whole) but also at the individual level of analysis (i.e., characteristics of family members as raters), indicating a lack of level validity. Evidence was provided for the level validity of a latent variable based on family members' ratings of whole-family warmth. The findings underscore the importance of assessing the level validity of individual ratings of whole-family functioning.

  2. Estimating Bandwidth Requirements using Flow-level Measurements

    NARCIS (Netherlands)

    Bruyère, P.; de Oliveira Schmidt, R.; Sperotto, Anna; Sadre, R.; Pras, Aiko

    Bandwidth provisioning is an important task of network management and it is done aiming to meet desired levels of quality of service. Current practices of provisioning are mostly based on rules-of-thumb and use coarse traffic measurements that may lead to problems of under and over dimensioning of

  3. Mutual inductance appliance for measuring the level of a molten metal

    International Nuclear Information System (INIS)

    Zbinden, Marc.

    1982-01-01

    The invention concerns an appliance for measuring the level of a molten metal of the kind using the variation of the mutual inductance between two imbricated windings depending on the level of the free area of the molten metal in the range of levels taken up by the windings. It has a particularly significant use in measuring the level of liquid sodium, especially in nuclear facilities where sodium is used as coolant [fr

  4. Effects of microelectronics on industrial level measuring

    International Nuclear Information System (INIS)

    Schaudel, D.E.

    1979-01-01

    Microelectronic elements and production technologies have begun to change industrial level measurement, and this trend will continue. Spectacular breakthroughs cannot be expected, due to the major demand of reliability and to administrative constraints. The demand for transducers has increased with the advance of low-cost computer hardware. Electronics makes well-known method of measurements more universally applicable; it helps to realize new methods, and to design multifunctional transducers which always give the necessary signal for process guidance. The effects on society and environment are wholly positive: More and better measuring technologies permit a better utilisation of raw materials and energies, help to prevent environmental damage, and to raise the standard of living. Negative results are not to be expected on this sector. (orig./RW) [de

  5. Global change and the measurement of absolute sea-level

    Science.gov (United States)

    Diamante, John M.; Pyle, Thomas E.; Carter, William E.; Scherer, Wolfgang

    To quantify properly the long-term response of sea-level to climate change, land motions must be separated from the apparent or relative sea-level change recorded by conventional tide/sea-level gauges. Here we present a concept for global measurement of the true or “absolute” sea-level change, which combines recent advances in space-based geodetic techniques with plans for a global sea-level network under the World Climate Research Programme (WCRP). Data from initial feasibility tests show that land motion, due to global (plate tectonic), regional (glacial rebound), or local (fluid withdrawal) effects, can probably be measured to ±1cm (on a single measurement basis) by an innovative combination of Very Long Baseline Interferometry (VLBI) and Global Positioning System (GPS) tevhniques. By making repeated observations of position at a number of tide gauges using portable, economical GPS receivers in a differential mode relative to the fewer, more stable, but more expensive VLBI observatories, it will be possible to subtract land motion from the relative sea-level signal. Decadal to century scale trends at the 1-2mm y -1 level will be resolvable in the sea-level and vertical land motion time series within about a decade. Detection of subsidence or uplift at specific gauges will allow correction for land motion or deletion of bad data when computing regional or global, i.e. eustatic, sea-level changes. In addition to their applications in oceanography and climate studies, such data will test models by Peltier and other that relate mantle viscosity and deglaciation history to present rates of crustal subsidence or uplift. If the predicted crustal motions are confirmed, we can also have more confidence in the use of historical tide/sea-level gauge records in retrospective studies of sea-level change related to climate variability on decadal or longer time scales. It is concluded that as few as one-third (about 100) of the total number of tide/sea-level gauges (250

  6. Relating measurement invariance, cross-level invariance, and multilevel reliability

    NARCIS (Netherlands)

    Jak, S.; Jorgensen, T.D.

    2017-01-01

    Data often have a nested, multilevel structure, for example when data are collected from children in classrooms. This kind of data complicate the evaluation of reliability and measurement invariance, because several properties can be evaluated at both the individual level and the cluster level, as

  7. Estimating retained gas volumes in the Hanford tanks using waste level measurements

    International Nuclear Information System (INIS)

    Whitney, P.D.; Chen, G.; Gauglitz, P.A.; Meyer, P.A.; Miller, N.E.

    1997-09-01

    The Hanford site is home to 177 large, underground nuclear waste storage tanks. Safety and environmental concerns surround these tanks and their contents. One such concern is the propensity for the waste in these tanks to generate and trap flammable gases. This report focuses on understanding and improving the quality of retained gas volume estimates derived from tank waste level measurements. While direct measurements of gas volume are available for a small number of the Hanford tanks, the increasingly wide availability of tank waste level measurements provides an opportunity for less expensive (than direct gas volume measurement) assessment of gas hazard for the Hanford tanks. Retained gas in the tank waste is inferred from level measurements -- either long-term increase in the tank waste level, or fluctuations in tank waste level with atmospheric pressure changes. This report concentrates on the latter phenomena. As atmospheric pressure increases, the pressure on the gas in the tank waste increases, resulting in a level decrease (as long as the tank waste is open-quotes softclose quotes enough). Tanks with waste levels exhibiting fluctuations inversely correlated with atmospheric pressure fluctuations were catalogued in an earlier study. Additionally, models incorporating ideal-gas law behavior and waste material properties have been proposed. These models explicitly relate the retained gas volume in the tank with the magnitude of the waste level fluctuations, dL/dP. This report describes how these models compare with the tank waste level measurements

  8. Respiratory health effects of man-made vitreous (mineral) fibres.

    Science.gov (United States)

    De Vuyst, P; Dumortier, P; Swaen, G M; Pairon, J C; Brochard, P

    1995-12-01

    The group of man-made mineral or vitreous fibres (MMMFs or MMVFs) includes glass wool, rock wool, slag wool, glass filaments and microfibres, and refractory ceramic fibres (RCFs). Experimental observations have provided evidence that some types of MMVF are bioactive under certain conditions. The critical role of size parameters has been demonstrated in cellular and animal experiments, when intact fibres are in direct contact with the target cells. It is, however, difficult to extrapolate the results from these studies to humans since they bypass inhalation, deposition, clearance and translocation mechanisms. Inhalation studies are more realistic, but show differences between animal species regarding their sensibility to tumour induction by fibres. Fibre biopersistence is an important factor, as suggested by recent inhalation studies, which demonstrate positive results with RCF for fibrosis, lung tumours and mesothelioma. There is no firm evidence that exposure to glass-, rock- and slag wool is associated with lung fibrosis, pleural lesions, or nonspecific respiratory disease in humans. Exposure to RCF could enhance the effects of smoking in causing airways obstruction. An elevated standard mortality ratio for lung cancer has been demonstrated in cohorts of workers exposed to MMVF, especially in the early technological phase of mineral (rock slag) wool production. During that period, several carcinogenic agents (arsenic, asbestos, polycyclic aromatic hydrocarbons (PAH)) were also present at the workplace and quantitative data about smoking and fibre levels are lacking. It is not possible from these data to determine whether the risk of lung cancer is due to the MMVFs themselves. No increased risk of mesothelioma has been demonstrated in the cohorts of workers exposed to glass-, slag- or rock wool. There are in fact insufficient epidemiological data available concerning neoplastic diseases in RCF production workers because of the small size of the workforce and the

  9. Importance of measuring lactate levels in children with sepsis.

    Science.gov (United States)

    Anil, Nisha

    2017-10-10

    Sepsis is a major public health problem as well as one of the leading causes of preventable death in children because of failure to recognise the early signs and symptoms and to resuscitate rapidly. Blood lactate levels are used to assess the severity of sepsis and the effectiveness of resuscitation. Lactate levels are easily obtainable and should be checked in all patients admitted with suspected sepsis within six hours of presentation. The test should be repeated four and eight-hours post-diagnosis of sepsis. For the diagnosis of sepsis, patients' clinical symptoms, along with the combined analysis of partial pressure of oxygen, carbon dioxide and lactate levels, should be used. A multitude of factors can cause elevated lactate levels and so clinicians should use elevated levels cautiously by considering all other aetiologies. This article, which focuses on practice in Australia but makes reference to the UK, discusses the importance of measuring lactate levels in sepsis, the pathophysiology of lactate production, causes of elevated lactate levels, lactate measurement, nursing management of patients with elevated lactate levels, limitations of using lactate as a biomarker for diagnosing sepsis and implications for practice. ©2012 RCN Publishing Company Ltd. All rights reserved. Not to be copied, transmitted or recorded in any way, in whole or part, without prior permission of the publishers.

  10. Unibert - PC software for radiometric level gauging - the LB440 measuring system

    International Nuclear Information System (INIS)

    Mann, H.; Bickert, M.

    2001-01-01

    In almost all industrial branches radiometric measuring systems are being used today for a lot of different tasks. The most common field of this application are level gauging measurements by use of gamma radiation, i.e. for level detection as well as for level gauging over ranges of up to several meters. For our level gauge measuring system LB440 we developed a clearly arranged PC software, which allows starting, measuring and service of the level gauge. Over the RS232-interface the industrial computer can be connected with a Laptop or PC. The software is a supplemental or even a substitute for the operation over the frontpanel. The measuring system can be completely controlled by the Unibert PC-Software, realised by LabVIEW 5.1.1, which offers an interactive graphical user interface. The same functionality as in the ''embedded - software'' is available, completed with some additional functions. (orig.) [de

  11. Measurement of Background Gamma Radiation Levels at Two ...

    African Journals Online (AJOL)

    MICHAEL

    ABSTRACT: An in-situ measurement of the background radiation level was carried out at the vicinity of three ... Soil contains small quantities of radioactive elements along with their progeny. .... assessment for soil samples from Kestanbol.

  12. Indirect measurement of molten steel level in tundish based on laser triangulation

    Science.gov (United States)

    Su, Zhiqi; He, Qing; Xie, Zhi

    2016-03-01

    For real-time and precise measurement of molten steel level in tundish during continuous casting, slag level and slag thickness are needed. Among which, the problem of slag thickness measurement has been solved in our previous work. In this paper, a systematic solution for slag level measurement based on laser triangulation is proposed. Being different from traditional laser triangulation, several aspects for measuring precision and robustness have been done. First, laser line is adopted for multi-position measurement to overcome the deficiency of single point laser range finder caused by the uneven surface of the slag. Second, the key parameters, such as installing angle and minimum requirement of the laser power, are analyzed and determined based on the gray-body radiation theory to fulfill the rigorous requirement of measurement accuracy. Third, two kinds of severe noises in the acquired images, which are, respectively, caused by heat radiation and Electro-Magnetic Interference (EMI), are cleaned via morphological characteristic of the liquid slag and color difference between EMI and the laser signals, respectively. Fourth, as false target created by stationary slag usually disorders the measurement, valid signals of the slag are distinguished from the false ones to calculate the slag level. Then, molten steel level is obtained by the slag level minus the slag thickness. The measuring error of this solution is verified by the applications in steel plants, which is ±2.5 mm during steady casting and ±3.2 mm at the end of casting.

  13. Indirect measurement of molten steel level in tundish based on laser triangulation

    Energy Technology Data Exchange (ETDEWEB)

    Su, Zhiqi; He, Qing, E-mail: heqing@ise.neu.edu.cn; Xie, Zhi [State Key Laboratory of Synthetical Automation for Process Industries, School of Information Science and Engineering, Northeastern University, Shenyang 110819 (China)

    2016-03-15

    For real-time and precise measurement of molten steel level in tundish during continuous casting, slag level and slag thickness are needed. Among which, the problem of slag thickness measurement has been solved in our previous work. In this paper, a systematic solution for slag level measurement based on laser triangulation is proposed. Being different from traditional laser triangulation, several aspects for measuring precision and robustness have been done. First, laser line is adopted for multi-position measurement to overcome the deficiency of single point laser range finder caused by the uneven surface of the slag. Second, the key parameters, such as installing angle and minimum requirement of the laser power, are analyzed and determined based on the gray-body radiation theory to fulfill the rigorous requirement of measurement accuracy. Third, two kinds of severe noises in the acquired images, which are, respectively, caused by heat radiation and Electro-Magnetic Interference (EMI), are cleaned via morphological characteristic of the liquid slag and color difference between EMI and the laser signals, respectively. Fourth, as false target created by stationary slag usually disorders the measurement, valid signals of the slag are distinguished from the false ones to calculate the slag level. Then, molten steel level is obtained by the slag level minus the slag thickness. The measuring error of this solution is verified by the applications in steel plants, which is ±2.5 mm during steady casting and ±3.2 mm at the end of casting.

  14. Measurements of radon levels inside Mexican caves

    International Nuclear Information System (INIS)

    Borau, J.; Gonzalez, A.; Espinosa, G.; Golzarri, J.I.

    1993-01-01

    Living animal species on earth have been exposed to environmental radon from the very beginning of time. The effects of radiation, combined with other natural parameters such as temperature, humidity, salt contents, etc., have most likely influenced the evaluation of different species. Thus, it is important to know and to evaluate the radon levels, among other radioactive elements present in enclosed environments such as caves, especially since those caves were also the dwellings and refuge of the predecessor of man. In this work we present radon level measurements inside some caves with vestiges of ancient inhabitats and some recently discovered natural caves, using Nuclear Track Detectors. (author)

  15. Measuring Levels of Work in Academic Libraries: A Time Based Approach.

    Science.gov (United States)

    Gould, Donald P.

    1985-01-01

    Using Stratified Systems Theory, which focuses on the manager-subordinate relationship in the bureaucratic structure, a study was conducted to measure level of responsibility in work of 37 professional and nonprofessional positions in four academic library technical services departments. Three levels of work were measured in "time-spans of…

  16. Noninvasive measurement of blood glucose level using mid-infrared quantum cascade lasers

    Science.gov (United States)

    Yoshioka, Kiriko; Kino, Saiko; Matsuura, Yuji

    2017-04-01

    For non-invasive measurement of blood glucose level, attenuated total reflection (ATR) absorption spectroscopy system using a QCL as a light source was developed. The results of measurement of glucose solutions showed that the system had a sensitivity that was enough for blood glucose measurement. In-vivo measurement using the proposed system based on QCL showed that there was a correlation between absorptions measured with human lips and blood glucose level.

  17. Recent advances in measurements of the nuclear level density

    International Nuclear Information System (INIS)

    John, Bency

    2007-01-01

    A short review of recent advances in measurements of the nuclear level density is given. First results of the inverse level density parameter - angular momentum correlation in a number of nuclei around Z∼50 shell region at an excitation energy around 0.3 MeV/nucleon are presented. Significant variations observed over and above the expected shell corrections are discussed in context of the emerging trends in microscopic calculations of the nuclear level density. (author)

  18. SAGE II Measurements of Stratospheric Aerosol Properties at Non-Volcanic Levels

    Science.gov (United States)

    Thomason, Larry W.; Burton, Sharon P.; Luo, Bei-Ping; Peter, Thomas

    2008-01-01

    Since 2000, stratospheric aerosol levels have been relatively stable and at the lowest levels observed in the historical record. Given the challenges of making satellite measurements of aerosol properties at these levels, we have performed a study of the sensitivity of the product to the major components of the processing algorithm used in the production of SAGE II aerosol extinction measurements and the retrieval process that produces the operational surface area density (SAD) product. We find that the aerosol extinction measurements, particularly at 1020 nm, remain robust and reliable at the observed aerosol levels. On the other hand, during background periods, the SAD operational product has an uncertainty of at least a factor of 2 during due to the lack of sensitivity to particles with radii less than 100 nm.

  19. Single uniform FBG for simultaneous measurement of liquid level and temperature

    International Nuclear Information System (INIS)

    Shu, Xuewen; Sugden, Kate; Bennion, Ian

    2010-01-01

    In this paper, we propose and demonstrate a novel scheme for simultaneous measurement of liquid level and temperature based on a simple uniform fiber Bragg grating (FBG) by monitoring both the short-wavelength-loss peaks and its Bragg resonance. The liquid level can be measured from the amplitude changes of the short-wavelength-loss peaks, while temperature can be measured from the wavelength shift of the Bragg resonance. Both theoretical simulation results and experimental results are presented. Such a scheme has some advantages including robustness, simplicity, flexibility in choosing sensitivity and simultaneous temperature measurement capability

  20. The Evaluation of Steam Generator Level Measurement Model for OPR1000 Using RETRAN-3D

    International Nuclear Information System (INIS)

    Doo Yong Lee; Soon Joon Hong; Byung Chul Lee; Heok Soon Lim

    2006-01-01

    Steam generator level measurement is important factor for plant transient analyses using best estimate thermal hydraulic computer codes since the value of steam generator level is used for steam generator level control system and plant protection system. Because steam generator is in the saturation condition which includes steam and liquid together and is the place that heat exchange occurs from primary side to secondary side, computer codes are hard to calculate steam generator level realistically without appropriate level measurement model. In this paper, we prepare the steam generator models using RETRAN-3D that include geometry models, full range feedwater control system and five types of steam generator level measurement model. Five types of steam generator level measurement model consist of level measurement model using elevation difference in downcomer, 1D level measurement model using fluid mass, 1D level measurement model using fluid volume, 2D level measurement model using power and fluid mass, and 2D level measurement model using power and fluid volume. And we perform the evaluation of the capability of each steam generator level measurement model by simulating the real plant transient condition, the title is 'Reactor Trip by The Failure of The Deaerator Level Control Card of Ulchin Unit 3'. The comparison results between real plant data and RETRAN-3D analyses for each steam generator level measurement model show that 2D level measurement model using power and fluid mass or fluid volume has more realistic prediction capability compared with other level measurement models. (authors)

  1. Measurement of Acceptable Noise Level with Background Music.

    Science.gov (United States)

    Ahn, Hyun-Jung; Bahng, Junghwa; Lee, Jae Hee

    2015-09-01

    Acceptable noise level (ANL) is a measure of the maximum background noise level (BNL) that a person is willing to tolerate while following a target story. Although researchers have used various sources of target sound in ANL measures, a limited type of background noise has been used. Extending the previous study of Gordon-Hickey & Moore (2007), the current study determined the effect of music genre and tempo on ANLs as possible factors affecting ANLs. We also investigated the relationships between individual ANLs and the familiarity of music samples and between music ANLs and subjective preference. Forty-one participants were seperated into two groups according to their ANLs, 29 low-ANL listeners and 12 high-ANL listeners. Using Korean ANL material, the individual ANLs were measured based on the listeners' most comfortable listening level and BNL. The ANLs were measured in six conditions, with different music tempo (fast, slow) and genre (K-pop, pop, classical) in a counterbalanced order. Overall, ANLs did not differ by the tempo of background music, but music genre significantly affected individual ANLs. We observed relatively higher ANLs with K-pop music and relatively lower ANLs with classical music. This tendency was similar in both low-ANL and high-ANL groups. However, the subjective ratings of music familiarity and preference affected ANLs differently for low-ANL and high-ANL groups. In contrast to the low-ANL listeners, the ANLs of the high-ANL listeners were significantly affected by music familiarity and preference. The genre of background music affected ANLs obtained using background music. The degree of music familiarity and preference appears to be associated with individual susceptibility to background music only for listeners who are greatly annoyed by background noise (high-ANL listeners).

  2. Ionization chamber for measurements of high-level tritium gas

    International Nuclear Information System (INIS)

    Carstens, D.H.W.; David, W.R.

    1980-01-01

    The construction and calibration of a simple ionization-chamber apparatus for measurement of high level tritium gas is described. The apparatus uses an easily constructed but rugged chamber containing the unknown gas and an inexpensive digital multimeter for measuring the ion current. The equipment after calibration is suitable for measuring 0.01 to 100% tritium gas in hydrogen-helium mixes with an accuracy of a few percent. At both the high and low limits of measurements deviations from the predicted theoretical current are observed. These are briefly discussed

  3. Introducing B2B Service Level Measures via a Poker-Card Activity

    Science.gov (United States)

    Chen, Chun-Miin; Bailey, Matthew D.

    2016-01-01

    To determine the appropriate level of product availability, most operations management textbooks introduce and define service level measures in a Business-to-Customer context. In other words, a retailer that wants to measure product availability in their store calculates the fill rate (FR) or cycle service level over an infinite review horizon.…

  4. A Pilot Study on Measuring Customer’s Satisfaction Level

    Directory of Open Access Journals (Sweden)

    Vide Boltez

    2013-01-01

    Full Text Available RQ: Determine the level of customer satisfaction of a company’s products and services to obtain information on needed improvements.Purpose: The purpose of measuring customer’s satisfaction level is to obtain information directly from the final buyer that bought our product. The next step is to analyze the information obtained and to take the results into consideration to improve the working process in production and in other departments of the company.Method: The method used for the pilot study to measure customer satisfaction was a short questionnaire that was given to 10 customers of our product and 10 completed questionnaires were obtained.Results: The results showed the level of satisfaction of final buyers of roof tiles and roofs that the company has achieved through their products and services. The results facilitate the production, logistics, purchasing and sales department to obtain information on positive satisfaction levels and areas that need change. At the same time, the final buyer was identified (i.e., name, surname, address, and so forth, which up until now had not been.Organization: The organization will save time and money in the future, because it will continuously measure customer satisfaction to improve production and other departments in the organization towards creating satisfied customers.Society: Final buyers of roofs are, and will be, more satisfied with their decisions, because the organization carries out after-sales satisfaction levels.Originality: The research was original, because up to this date the organization has not conducted research in such a manner.Limitations: The pilot study used 10 completed questionnaires that represent a very small sample to make any generalizations.

  5. Symmetry and Asymmetry Level Measures

    Directory of Open Access Journals (Sweden)

    Angel Garrido

    2010-04-01

    Full Text Available Usually, Symmetry and Asymmetry are considered as two opposite sides of a coin: an object is either totally symmetric, or totally asymmetric, relative to pattern objects. Intermediate situations of partial symmetry or partial asymmetry are not considered. But this dichotomy on the classification lacks of a necessary and realistic gradation. For this reason, it is convenient to introduce "shade regions", modulating the degree of Symmetry (a fuzzy concept. Here, we will analyze the Asymmetry problem by successive attempts of description and by the introduction of the Asymmetry Level Function, as a new Normal Fuzzy Measure. Our results (both Theorems and Corollaries suppose to be some new and original contributions to such very active and interesting field of research. Previously, we proceed to the analysis of the state of art.

  6. Recent Advances in Low-Level Nuclear Measurements at the CEA

    International Nuclear Information System (INIS)

    Mahe, C.; Lamadie, F.; Le Goaller, C.

    2009-01-01

    For several years the CEA has been performing nuclear measurements at different stages of decommissioning projects. The characterization tools initially developed for high-level radioactive waste analysis must be adapted to a new area of application: low-level measurements. Recent technical improvements in gamma imaging, gamma spectrometry detectors, and data analysis make it possible to provide relevant radiological data for waste management, as well as to develop robust and optimized decommissioning scenarios from the initial dose rate mapping to the final declared activity. These techniques have been implemented at various nuclear sites for both trial measurement campaigns and expert investigations to localize residual contamination, to identify the radioelements and to provide an accurate estimate of the declarable activity. Different types of measurements and devices have been used: gamma cameras, coded aperture techniques, alpha imaging prototypes, gamma spectrometry detectors (CdZnTe, HPGe, NaI, and LaBr 3 ), dose rate cartography, and calculation codes (Mercure, MCNP, etc.), all of which provide complementary data for radioactive waste categorization. This paper describes the latest developments and methods deployed on decommissioning projects focusing on low-level in situ applications. Waste drum characterization and in situ glove box measurements are discussed and the technologies and performance of gamma imaging systems, gamma spectrometry detectors, calculation codes and software are described. The paper concludes with a review of future developments and tests necessary for these applications. (authors)

  7. Method of calibrating a fluid-level measurement system

    Science.gov (United States)

    Woodard, Stanley E. (Inventor); Taylor, Bryant D. (Inventor)

    2010-01-01

    A method of calibrating a fluid-level measurement system is provided. A first response of the system is recorded when the system's sensor(s) is (are) not in contact with a fluid of interest. A second response of the system is recorded when the system's sensor(s) is (are) fully immersed in the fluid of interest. Using the first and second responses, a plurality of expected responses of the system's sensor(s) is (are) generated for a corresponding plurality of levels of immersion of the sensor(s) in the fluid of interest.

  8. RLV-TD Flight Measured Aeroacoustic Levels and its Comparison with Predictions

    Science.gov (United States)

    Manokaran, K.; Prasath, M.; Venkata Subrahmanyam, B.; Ganesan, V. R.; Ravindran, Archana; Babu, C.

    2017-12-01

    The Reusable Launch Vehicle-Technology Demonstrator (RLV-TD) is a wing body configuration successfully flight tested. One of the important flight measurements is the acoustic levels. There were five external microphones, mounted on the fuselage-forebody, wing, vertical tail, inter-stage (ITS) and core base shroud to measure the acoustic levels from lift-off to splash down. In the ascent phase, core base shroud recorded the overall maximum at both lift-off and transonic conditions. In-flight noise levels measured on the wing is second highest, followed by fuselage and vertical tail. Predictions for flight trajectory compare well at all locations except for vertical tail (4.5 dB). In the descent phase, maximum measured OASPL occurs at transonic condition for the wing, followed by vertical tail and fuselage. Predictions for flight trajectory compare well at all locations except for wing (- 6.0 dB). Spectrum comparison is good in the ascent phase compared to descent phase. Roll Reaction control system (RCS) thruster firing signature is seen in the acoustic measurements on the wing and vertical tail during lift-off.

  9. Indoor radon level measurements in Iran using AEOI passive dosimeters

    International Nuclear Information System (INIS)

    Sohrabi, M.; Solaymanian, A.R.

    1988-01-01

    A passive radon diffusion dosimeter was developed at the RPD of AEOI for nationwide indoor radon level measurements. Several parameters of the dosimeter were studied. Radon levels were determined in about 250 houses in Ramsar (a high natural radiation area), Tehran, Babolsar and Gonabad. In this paper, the results of some dosimeter parameters as well as radon levels in indoor air are reported

  10. Measuring and Assessment the Noise Level in Different Regions in Baghdad City And Compare it with The Allowable Levels

    Directory of Open Access Journals (Sweden)

    Ibtihaj Abdulwahhab Abdulrazzak

    2017-05-01

    Full Text Available This study includes measurement of the noise level of four regions in the city of Baghdad (industrial region, commercial region, residential region and quiet region and compare the value of noise in each region with the World Health Organization (WHO allowable limits, and the effect of noise on human health was explained. The "sound level meter (SLM" instrument measuring the noise value in the four regions, three measurement per month through one year was recorded (one measurement every ten days from 1/1/2015 to 30/12/2015. The noise level of the industrial region (75dB compared with the World Health Organization level allowable limit (65dB, while the commercial region (76.28dB versus (55dB and the residential region (74.94dB versus (50dB and the quiet region was (62.36dB versus (40dB of the (WHO allowable limit.

  11. Seasonality in Children's Pedometer-Measured Physical Activity Levels

    Science.gov (United States)

    Beighle, Aaron; Alderman, Brandon; Morgan, Charles F.; Le Masurier, Guy

    2008-01-01

    Seasonality appears to have an impact on children's physical activity levels, but equivocal findings demand more study in this area. With the increased use of pedometers in both research and practice, collecting descriptive data in various seasons to examine the impact of seasonality on pedometer-measured physical activity among children is…

  12. Use of inexpensive pressure transducers for measuring water levels in wells

    Science.gov (United States)

    Keeland, B.D.; Dowd, J.F.; Hardegree, W.S.

    1997-01-01

    Frequent measurement of below ground water levels at multiple locations is an important component of many wetland ecosystem studies. These measurements, however, are usually time consuming, labor intensive, and expensive. This paper describes a water-level sensor that is inexpensive and easy to construct. The sensor is placed below the expected low water level in a shallow well and, when connected to a datalogger, uses a pressure transducer to detect groundwater or surface water elevations. Details of pressure transducer theory, sensor construction, calibration, and examples of field installations are presented. Although the transducers must be individually calibrated, the sensors have a linear response to changing water levels (r2 ??? .999). Measurement errors resulting from temperature fluctuations are shown to be about 4 cm over a 35??C temperature range, but are minimal when the sensors are installed in groundwater wells where temperatures are less variable. Greater accuracy may be obtained by incorporating water temperature data into the initial calibration (0.14 cm error over a 35??C temperature range). Examples of the utility of these sensors in studies of groundwater/surface water interactions and the effects of water level fluctuations on tree growth are provided. ?? 1997 Kluwer Academic Publishers.

  13. Optimal Fasting Time before Measurement of Serum Triglyceride Levels in Healthy Volunteers.

    Science.gov (United States)

    Pongsuthana, Surapun; Tivatunsakul, Naris

    2016-02-01

    Coronary heart disease is a major public health problem. Elevated triglyceride levels are a risk factor for atherosclerosis and coronary heart disease. Food intake interferes with the measurement of serum triglyceride levels, and in previous studies, fasting for 12 hours was recommended before blood sampling. In real-world practice, long fasting times cause patient discomfort and poor compliance, and the present study was, therefore, designed to determine the appropriate fasting time prior to measuring serum triglyceride levels. To determine the appropriate fasting time before measuring serum triglyceride levels. This was a pilot study performed using healthy volunteers aged between 20 and 30 years old from November 2013 to December 2013 at Rajavithi Hospital. The first blood sample was measured in the morning after fasting over 12 hours. The subjects then took their regular breakfast, after which they fasted for 8 hours. Blood samples were taken 6 and 8 hours later and sent to the laboratory for measurement of serum triglyceride levels. 40 volunteers, of whom 25 were female, were enrolled. Their mean age was 25.9 ± 2.81 years old, and their mean weight, height, and body mass index were 61.5 ± 12.5 kg, 167.2 ± 8.3 cm and 21.84 ± 3.1 kg/m2, respectively. Mean fasting serum triglyceride level at 12 hours was 80.23 ± 36.33 mg/dl, at 6 hours it was 110.65 ± 73.45 mg/dl, and at 8 hours it was 75.62 ± 46.81 mg/dl. The group fasting for 12 hours had significantly lower serum triglyceride levels than the group fasting for 6 hours (p-value = 0.003), but no significant difference was found between the group fasting for 12 hours and the one fasting for 8 hours (p-value = 0.493). The present study showed no significant difference in triglyceride levels in patients who had fasted or 8 hours and those who had done so for 12 hours. Fasting for only 8 hours before measurement of serum triglyceride may be sufficient.

  14. Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech

    Science.gov (United States)

    Švec, Jan G.; Granqvist, Svante

    2018-01-01

    Purpose: Sound pressure level (SPL) measurement of voice and speech is often considered a trivial matter, but the measured levels are often reported incorrectly or incompletely, making them difficult to compare among various studies. This article aims at explaining the fundamental principles behind these measurements and providing guidelines to…

  15. Individual v. community-level measures of women's decision-making ...

    African Journals Online (AJOL)

    Individual v. community-level measures of women's decision-making involvement and ... participation for child survival in sub-Saharan Africa is limited. ... Multilevel discrete-time hazard models were employed to investigate the net effect of ...

  16. DUQuE quality management measures: associations between quality management at hospital and pathway levels.

    Science.gov (United States)

    Wagner, Cordula; Groene, Oliver; Thompson, Caroline A; Dersarkissian, Maral; Klazinga, Niek S; Arah, Onyebuchi A; Suñol, Rosa

    2014-04-01

    The assessment of integral quality management (QM) in a hospital requires measurement and monitoring from different perspectives and at various levels of care delivery. Within the DUQuE project (Deepening our Understanding of Quality improvement in Europe), seven measures for QM were developed. This study investigates the relationships between the various quality measures. It is a multi-level, cross-sectional, mixed-method study. As part of the DUQuE project, we invited a random sample of 74 hospitals in 7 countries. The quality managers of these hospitals were the main respondents. Furthermore, data of site visits of external surveyors assessing the participating hospitals were used. Three measures of QM at hospitals level focusing on integral systems (QMSI), compliance with the Plan-Do-Study-Act quality improvement cycle (QMCI) and implementation of clinical quality (CQII). Four measures of QM activities at care pathway level focusing on Specialized expertise and responsibility (SER), Evidence-based organization of pathways (EBOP), Patient safety strategies (PSS) and Clinical review (CR). Positive significant associations were found between the three hospitals level QM measures. Results of the relationships between levels were mixed and showed most associations between QMCI and department-level QM measures for all four types of departments. QMSI was associated with PSS in all types of departments. By using the seven measures of QM, it is possible to get a more comprehensive picture of the maturity of QM in hospitals, with regard to the different levels and across various types of hospital departments.

  17. Development of capacitive sensor for automatically measuring tumbler water level with FEA simulation.

    Science.gov (United States)

    Wei, Qun; Kim, Mi-Jung; Lee, Jong-Ha

    2018-01-01

    Drinking water has several advantages that have already been established, such as improving blood circulation, reducing acid in the stomach, etc. However, due to people not noticing the amount of water they consume every time they drink, most people drink less water than the recommended daily allowance. In this paper, a capacitive sensor for developing an automatic tumbler to measure water level is proposed. Different than in previous studies, the proposed capacitive sensor was separated into two sets: the main sensor for measuring the water level in the tumbler, and the reference sensor for measuring the incremental level unit. In order to confirm the feasibility of the proposed idea, and to optimize the shape of the sensor, a 3D model of the capacitive sensor with the tumbler was designed and subjected to Finite Element Analysis (FEA) simulation. According to the simulation results, the electrodes were made of copper and assembled in a tumbler manufactured by a 3D printer. The tumbler was filled with water and was subjected to experiments in order to assess the sensor's performance. The comparison of experimental results to the simulation results shows that the measured capacitance value of the capacitive sensor changed linearly as the water level varied. This proves that the proposed sensor can accurately measure the water level in the tumbler. Additionally, by use of the curve fitting method, a compensation algorithm was found to match the actual level with the measured level. The experimental results proved that the proposed capacitive sensor is able to measure the actual water level in the tumbler accurately. A digital control part with micro-processor will be designed and fixed on the bottom of the tumbler for developing a smart tumbler.

  18. Measuring patient safety culture: an assessment of the clustering of responses at unit level and hospital level

    NARCIS (Netherlands)

    Smits, M.; Wagner, C.; Spreeuwenberg, P.; Wal, van der G.

    2009-01-01

    OBJECTIVES: To test the claim that the Hospital Survey on Patient Safety Culture (HSOPS) measures patient safety culture instead of mere individual attitudes and to determine the most appropriate level (individual, unit or hospital level) for interventions aimed at improving the culture of patient

  19. Measuring patient safety culture : an assessment of the clustering of responses at unit level and hospital level

    NARCIS (Netherlands)

    Smits, M.; Wagner, C.; Spreeuwenberg, P.; Wal, G. van der; Groenewegen, P.P.

    2009-01-01

    Objectives: To test the claim that the Hospital Survey on Patient Safety Culture (HSOPS) measures patient safety culture instead of mere individual attitudes and to determine the most appropriate level (individual, unit or hospital level) for interventions aimed at improving the culture of patient

  20. An approach for the accurate measurement of social morality levels.

    Science.gov (United States)

    Liu, Haiyan; Chen, Xia; Zhang, Bo

    2013-01-01

    In the social sciences, computer-based modeling has become an increasingly important tool receiving widespread attention. However, the derivation of the quantitative relationships linking individual moral behavior and social morality levels, so as to provide a useful basis for social policy-making, remains a challenge in the scholarly literature today. A quantitative measurement of morality from the perspective of complexity science constitutes an innovative attempt. Based on the NetLogo platform, this article examines the effect of various factors on social morality levels, using agents modeling moral behavior, immoral behavior, and a range of environmental social resources. Threshold values for the various parameters are obtained through sensitivity analysis; and practical solutions are proposed for reversing declines in social morality levels. The results show that: (1) Population size may accelerate or impede the speed with which immoral behavior comes to determine the overall level of social morality, but it has no effect on the level of social morality itself; (2) The impact of rewards and punishment on social morality levels follows the "5∶1 rewards-to-punishment rule," which is to say that 5 units of rewards have the same effect as 1 unit of punishment; (3) The abundance of public resources is inversely related to the level of social morality; (4) When the cost of population mobility reaches 10% of the total energy level, immoral behavior begins to be suppressed (i.e. the 1/10 moral cost rule). The research approach and methods presented in this paper successfully address the difficulties involved in measuring social morality levels, and promise extensive application potentials.

  1. Measuring Structural Gender Equality in Mexico: A State Level Analysis

    Science.gov (United States)

    Frias, Sonia M.

    2008-01-01

    The main goal of this article is to assess the level of gender equality across the 32 Mexican states. After reviewing conceptual and methodological issues related to previous measures of structural inequality I detail the logic and methodology involved in the construction of a composite and multidimensional measure of gender equality, at the…

  2. Level measurements part 2[5 figs]; Nivaamaalinger del 2

    Energy Technology Data Exchange (ETDEWEB)

    Gundersen, Thor Ole

    2006-07-01

    The article discusses various level measurement methods other than using ultrasound that was discussed in part 1 of the article series. Methods using laser, capacity, weight and displacement are presented. Various life span aspects of the machinery are discussed.

  3. Instructions for 104-SX liquid level measurement field tests

    International Nuclear Information System (INIS)

    Webb, R.H.

    1994-01-01

    This document provides detailed instructions for field testing a suggested solution of inserting a liner inside the 104-SX failed Liquid Observation Well to gain access for making temporary Liquid Level Measurement until a permanent solution has been provided

  4. An ultrasound mini-balance for measurement of therapy level ultrasound

    International Nuclear Information System (INIS)

    Sutton, Yvonne; McBride, Karne; Pye, Stephen

    2006-01-01

    This paper describes a cost-effective method for measuring acoustic power using a radiation force balance. The device is based around a long established balance design with a gantry arrangement fitted with an absorbing target. The notion of this balance design is that it can easily be constructed from materials that would be readily available within a clinical or industrial environment. The mini-balance was calibrated using a transfer standard against an NPL Reference balance, so a comparison of the performance between the two systems could be assessed. The measurements were completed at 1 MHz and 3 MHz and over the acoustic power range of 1 W to 15 W. The results show the acoustic power measured on the mini-balance to be within 5% of the reference measurements made on the NPL Balance. A separate systematic uncertainty budget is also presented based on studies made on the balance and on similar systems. The overall expanded uncertainty was calculated to be within 14% at 1 W level, decreasing with increasing power level to 7.4% above 5 W

  5. Pilot study of methods and equipment for in-home noise level measurements.

    Science.gov (United States)

    Neitzel, Richard L; Heikkinen, Maire S A; Williams, Christopher C; Viet, Susan Marie; Dellarco, Michael

    2015-01-15

    Knowledge of the auditory and non-auditory effects of noise has increased dramatically over the past decade, but indoor noise exposure measurement methods have not advanced appreciably, despite the introduction of applicable new technologies. This study evaluated various conventional and smart devices for exposure assessment in the National Children's Study. Three devices were tested: a sound level meter (SLM), a dosimeter, and a smart device with a noise measurement application installed. Instrument performance was evaluated in a series of semi-controlled tests in office environments over 96-hour periods, followed by measurements made continuously in two rooms (a child's bedroom and a most used room) in nine participating homes over a 7-day period with subsequent computation of a range of noise metrics. The SLMs and dosimeters yielded similar A-weighted average noise levels. Levels measured by the smart devices often differed substantially (showing both positive and negative bias, depending on the metric) from those measured via SLM and dosimeter, and demonstrated attenuation in some frequency bands in spectral analysis compared to SLM results. Virtually all measurements exceeded the Environmental Protection Agency's 45 dBA day-night limit for indoor residential exposures. The measurement protocol developed here can be employed in homes, demonstrates the possibility of measuring long-term noise exposures in homes with technologies beyond traditional SLMs, and highlights potential pitfalls associated with measurements made by smart devices.

  6. High frequency electric field levels: An example of determination of measurement uncertainty for broadband measurements

    Directory of Open Access Journals (Sweden)

    Vulević Branislav

    2016-01-01

    Full Text Available Determining high frequency electromagnetic field levels in urban areas represents a very complex task, having in mind the exponential growth of the number of sources embodied in public cellular telephony systems in the past twenty years. The main goal of this paper is a representation of a practical solution in the evaluation of measurement uncertainty for in-situ measurements in the case of spatial averaging. An example of the estimation of the uncertainty for electric field strength broadband measurements in the frequency range from 3 MHz to 18 GHz is presented.

  7. Measurements on low level plutonium sources using Rad Elec Electret Ion Chambers

    International Nuclear Information System (INIS)

    Levinskas, D.; Teagarden, J.; Wilkes, E.

    1998-01-01

    This is a technique for measuring gross alpha particle emission from interior contaminated surfaces. The technique utilizes electret ionization chambers (EICs), which consist of a charged Teflon plate (the electret) and an electrically-conductive plastic chamber of 145 ml volume. To measure very low levels of alpha contamination, the EIC is left in place on the surface to be measured for about 48 hours. The change in the surface charge of the electret is a measure of the ionization during the measurement period. The rate of change of the charge is converted into an activity using an appropriate calibration factor. This system has the ability to make accurate gross alpha contamination measurements while being subject to a high airborne radon concentration, such as might occur in certain buildings or during an atmospheric inversion. Previous studies of the effectiveness of these EIC's focused on levels of alpha contamination much higher than is allowed for unrestricted release of material at the Rocky Flats Environmental Technology Site (RFETS). This study evaluated the performance of EIC's at levels from 100 disintegrations per minute (dpm) per 100 cm 2 to below 20 dpm per 100 cm 2 (all measurements are referenced to a 4π geometry). The EIC's were found to be within 5% accuracy, as compared to a gas flow proportional counter calibrated with a NIST-traceable source. Test results indicate that the EIC, left in place for 48 hours, can detect alpha contamination as low as 6.4 ± 3.0 dpm/100 cm 2 to a 95% confidence level

  8. Long-term cortisol levels measured in scalp hair of obese patients.

    Science.gov (United States)

    Wester, Vincent L; Staufenbiel, Sabine M; Veldhorst, Margriet A B; Visser, Jenny A; Manenschijn, Laura; Koper, Jan W; Klessens-Godfroy, Francoise J M; van den Akker, Erica L T; van Rossum, Elisabeth F C

    2014-09-01

    In obese subjects a relatively high cortisol output in urine has been observed compared to nonobese individuals. However, cortisol levels in blood, saliva, and urine in association with obesity have been inconsistent across studies, possibly due to the high variability of systemic cortisol levels. Cortisol levels measured in scalp hair provide a marker for long-term cortisol exposure, and have been associated with cardiovascular disease in an elderly population and to disease course in Cushing's disease. We aimed to compare hair cortisol levels between obese patients and nonobese controls. Hair cortisol levels of 47 obese patients (median BMI 38.8, range 31.1-65.8), 41 overweight, and 87 normal-weight subjects using an enzyme-linked immunosorbent assay (ELISA) were measured. Obese patients had higher hair cortisol levels than overweight and normal weight subjects (respectively 30.8 vs 8.5 and 8.4 pg/mg hair, P cortisol levels was found between normal weight and overweight subjects. Our results suggest a higher long-term cortisol exposure in obese patients, which may contribute to cardiovascular disease risk. Future research will determine whether long-term cortisol levels provide a novel treatment target in the management of cardiovascular disease risk in obesity. © 2014 The Obesity Society.

  9. Moisture separator for steam generator level measurement system

    International Nuclear Information System (INIS)

    Cantineau, B.J.

    1987-01-01

    A steam generator level measurement system having a reference leg which is kept full of water by a condensation pot, has a liquid/steam separator in the connecting line between the condensation pot and the steam phase in the steam generator to remove excess liquid from the steam externally of the steam generator. This ensures that the connecting line does not become blocked. The separator pot has an expansion chamber which slows down the velocity of the steam/liquid mixture to aid in separation, and a baffle, to avoid liquid flow into the line connected to the condensate pot. Liquid separated is returned to the steam generator below the water level through a drain line. (author)

  10. Challenges in standardization of blood pressure measurement at the population level.

    Science.gov (United States)

    Tolonen, Hanna; Koponen, Päivikki; Naska, Androniki; Männistö, Satu; Broda, Grazyna; Palosaari, Tarja; Kuulasmaa, Kari

    2015-04-10

    Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed. The European Health Examination Survey (EHES) Pilot project was conducted in 2009-2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization. The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement. It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.

  11. A measurement error model for physical activity level as measured by a questionnaire with application to the 1999-2006 NHANES questionnaire.

    Science.gov (United States)

    Tooze, Janet A; Troiano, Richard P; Carroll, Raymond J; Moshfegh, Alanna J; Freedman, Laurence S

    2013-06-01

    Systematic investigations into the structure of measurement error of physical activity questionnaires are lacking. We propose a measurement error model for a physical activity questionnaire that uses physical activity level (the ratio of total energy expenditure to basal energy expenditure) to relate questionnaire-based reports of physical activity level to true physical activity levels. The 1999-2006 National Health and Nutrition Examination Survey physical activity questionnaire was administered to 433 participants aged 40-69 years in the Observing Protein and Energy Nutrition (OPEN) Study (Maryland, 1999-2000). Valid estimates of participants' total energy expenditure were also available from doubly labeled water, and basal energy expenditure was estimated from an equation; the ratio of those measures estimated true physical activity level ("truth"). We present a measurement error model that accommodates the mixture of errors that arise from assuming a classical measurement error model for doubly labeled water and a Berkson error model for the equation used to estimate basal energy expenditure. The method was then applied to the OPEN Study. Correlations between the questionnaire-based physical activity level and truth were modest (r = 0.32-0.41); attenuation factors (0.43-0.73) indicate that the use of questionnaire-based physical activity level would lead to attenuated estimates of effect size. Results suggest that sample sizes for estimating relationships between physical activity level and disease should be inflated, and that regression calibration can be used to provide measurement error-adjusted estimates of relationships between physical activity and disease.

  12. The analysis of the bedrock deformation in Olkiluoto using precise levelling measurements

    International Nuclear Information System (INIS)

    Saaranen, V.; Rouhiainen, P.; Suurmaeki, H.

    2014-01-01

    In order to research vertical bedrock deformations in the Olkiluoto area, Posiva Oy and the Finnish Geodetic Institute began monitoring with precise levelling in 2003. At the moment, the measuring plan includes a loop between the monitoring GPS stations around the island, a levelling line from the island to the mainland, levelling loops to ONKALO, the final disposal site, and VLJ, the low and intermediate level waste repository there. The levelling to the mainland has been performed every fourth year and the levelling of the GPS stations every second year. The micro loops (ONKALO and VLJ) have been measured annually. In this report, we use three-step method to research a vertical deformation of the Olkiluoto area. Firstly, the linear deformation rate in the area has been determined by the least squares adjustment of the levelling data. It varies from -0.2 mm/yr to +0.2 mm/yr. Secondly, local deformations have been analysed by comparing the height differences for different years. In this comparison a starting value for the yearly adjustment has been corrected for land uplift. Using this method the elevation changes are relative to the whole network. For a fixed benchmark, we correct its yearly deformation. Thirdly, the fault lines have been analysed by comparing the elevation changes between the successive benchmarks from one observation epoch to another. The results show that ONKALO and Lapijoki are in the subsidence area of the network, and VLJ has small uplift rate. On the island some deformations exist, but elevation difference from 2003 to 2011 is less than one millimetre at every benchmarks. The measurements in the Lapijoki-Olkiluoto line in 2003, 2007 and 2011 show that linear elevation change between the mainland and Olkiluoto island is a little since 2003. The elevation differences, from Olkiluoto to Lapijoki, measured in 2003 and 2011 differ less than one millimetre each other, but the 2007 observation differs three millimetres from the other measurements

  13. THE LEVEL OF CUSTOMER SATISFACTION - MEASURE OF SOCIAL EFFICIENCY

    Directory of Open Access Journals (Sweden)

    MUNGIU-PUPĂZAN MARIANA CLAUDIA

    2014-05-01

    Full Text Available Pricing models for social efficiency focuses on assessing the quality, namely the comparison of the desired product to the consumer and the product received, the level of consumer satisfaction on the products and / or services will be therefore a very important component in measuring the effectiveness social. Between the two concepts there is a relationship of mutual interdependence: the level of consumer satisfaction is the result of the quality performance of products and services and high quality products and services is reflected in consumer satisfaction. From the theoretical point of view, according to the marketing strategy, it is necessary to bring to a common level of perceived benefit to consumer expectations. Customer satisfaction is actually the result of a complex information processing.

  14. Application of smart transmitter technology in nuclear engineering measurements with level detection algorithm

    International Nuclear Information System (INIS)

    Kang, Hyun Gook; Seong, Poong Hyun

    1994-01-01

    In this study a programmable smart transmitter is designed and applied to the nuclear engineering measurements. In order to apply the smart transmitter technology to nuclear engineering measurements, the water level detection function is developed and applied in this work. In the real time system, the application of level detection algorithm can make the operator of the nuclear power plant sense the water level more rapidly. Furthermore this work can simplify the data communication between the level-sensing thermocouples and the main signal processor because the level signal is determined at field. The water level detection function reduces the detection time to about 8.3 seconds by processing the signal which has the time constant 250 seconds and the heavy noise signal

  15. Measuring Resistance to Change at the Within-Session Level

    Science.gov (United States)

    Tonneau, Francois; Rios, Americo; Cabrera, Felipe

    2006-01-01

    Resistance to change is often studied by measuring response rate in various components of a multiple schedule. Response rate in each component is normalized (that is, divided by its baseline level) and then log-transformed. Differential resistance to change is demonstrated if the normalized, log-transformed response rate in one component decreases…

  16. Improvements on Low Level Activity Gamma Measurements and X-ray Spectrometry at the CEA-MADERE Measurement Platform

    Directory of Open Access Journals (Sweden)

    Sergeyeva Victoria

    2016-01-01

    Full Text Available The CEA MADERE platform (Measurement Applied to DosimEtry in REactors is a part of the Instrumentation Sensors and Dosimetry Laboratory (LDCI. This facility is dedicated to the specific activity measurements of solid and radioactive samples using Gamma and X-ray spectrometry. MADERE is a high-performance facility devoted to neutron dosimetry for experimental programs performed in CEA and for the irradiation surveillance programmes of PWR vessels. The MADERE platform is engaged in a continuous improvement process. Recently, two High Efficiency diodes have been integrated to the MADERE platform in order to manage the accurate low level activity measurements (few Bq per sample. This new equipment provides a good level of efficiency over the energy range from 60 keV to 2 MeV. The background continuum is reduced due to the use of a Ultra Low Background (ULB lead shielding. Relative and absolute X-ray measurement techniques have been improved in order to facilitate absolute rhodium activity measurement (Rh103m on solid samples. Additional efforts have been made to increase the accuracy of the relative niobium (Nb93m activity measurement technique. The way of setting up an absolute measurement method for niobium is under investigation. After a presentation of the MADERE's measurement devices, this paper focuses on the technological options taken into account for the design of high efficiency measurement devices. Then, studies performed on X-ray measurement techniques are presented. Some details about the calculation of uncertainties and correction factors are also mentioned. Finally, future research and development axes are exposed.

  17. Measuring receptive collocational competence across proficiency levels

    Directory of Open Access Journals (Sweden)

    Déogratias Nizonkiza

    2015-12-01

    Full Text Available The present study investigates, (i English as Foreign Language (EFL learners’ receptive collocational knowledge growth in relation to their linguistic proficiency level; (ii how much receptive collocational knowledge is acquired as proficiency develops; and (iii the extent to which receptive knowledge of collocations of EFL learners varies across word frequency bands. A proficiency measure and a collocation test were administered to English majors at the University of Burundi. Results of the study suggest that receptive collocational competence develops alongside EFL learners’ linguistic proficiency; which lends empirical support to Gyllstad (2007, 2009 and Author (2011 among others, who reported similar findings. Furthermore, EFL learners’ collocations growth seems to be quantifiable wherein both linguistic proficiency level and word frequency occupy a crucial role. While more gains in terms of collocations that EFL learners could potentially add as a result of change in proficiency are found at lower levels of proficiency; collocations of words from more frequent word bands seem to be mastered first, and more gains are found at more frequent word bands. These results confirm earlier findings on the non-linearity nature of vocabulary growth (cf. Meara 1996 and the fundamental role played by frequency in word knowledge for vocabulary in general (Nation 1983, 1990, Nation and Beglar 2007, which are extended here to collocations knowledge.

  18. The measurement for level of marine high-temperature and high-pressure vessels

    International Nuclear Information System (INIS)

    Lin Jie.

    1986-01-01

    The various error factors in measurement for level of marine high-temperature and high-pressure vessels are anslysed. The measuring method of error self compensation and its simplification for land use are shown

  19. Measuring water level in rivers and lakes from lightweight Unmanned Aerial Vehicles

    DEFF Research Database (Denmark)

    Bandini, Filippo; Jakobsen, Jakob; Olesen, Daniel Haugård

    2017-01-01

    The assessment of hydrologic dynamics in rivers, lakes, reservoirs and wetlands requires measurements of water level, its temporal and spatial derivatives, and the extent and dynamics of open water surfaces. Motivated by the declining number of ground-based measurement stations, research efforts...... complex water dynamics. Unmanned Aerial Vehicles (UAVs) can fill the gap between spaceborne and ground-based observations, and provide high spatial resolution and dense temporal coverage data, in quick turn-around time, using flexible payload design. This study focused on categorizing and testing sensors......, which comply with the weight constraint of small UAVs (around 1.5 kg), capable of measuring the range to water surface. Subtracting the measured range from the vertical position retrieved by the onboard Global Navigation Satellite System (GNSS) receiver, we can determine the water level (orthometric...

  20. Deep subcritical levels measurements dependents upon kinetic distortion factors

    International Nuclear Information System (INIS)

    Pan Shibiao; Li Xiang; Fu Guo'en; Huang Liyuan; Mu Keliang

    2013-01-01

    The measurement of deep subcritical levels, with the increase of subcriticality, showed that the results impact on the kinetic distortion effect, along with neutron flux strongly deteriorated. Using the diffusion theory, calculations have been carried out to quantify the kinetic distortion correction factors in subcritical systems, and these indicate that epithermal neutron distributions are strongly affected by kinetic distortion. Subcriticality measurements in four different rod-state combination at the zero power device was carried out. The test data analysis shows that, with increasing subcriticality, kinetic distortion effect correction factor gradually increases from 1.052 to 1.065, corresponding reactive correction amount of 0.78β eff ∼ 3.01β eff . Thus, it is necessary to consider the kinetic distortion effect in the deep subcritical reactivity measurements. (authors)

  1. Validation of hindi translation of DSM-5 level 1 cross-cutting symptom measure.

    Science.gov (United States)

    Goel, Ankit; Kataria, Dinesh

    2018-04-01

    The DSM-5 Level 1 Cross-Cutting Symptom Measure is a self- or informant-rated measure that assesses mental health domains which are important across psychiatric diagnoses. The absence of this self- or informant-administered instrument in Hindi, which is a major language in India, is an important limitation in using this scale. To translate the English version of the DSM-5 Level 1 Cross-Cutting Symptom Measure to Hindi and evaluate its psychometric properties. The study was conducted at a tertiary care hospital in Delhi. The DSM-5 Level 1 Cross-Cutting Symptom Measure was translated into Hindi using the World Health Organization's translation methodology. Mean and standard deviation were evaluated for continuous variables while for categorical variables frequency and percentages were calculated. The translated version was evaluated for cross-language equivalence, test-retest reliability, internal consistency, and split half reliability. Hindi version was found to have good cross-language equivalence and test-retest reliability at the level of items and domains. Twenty two of the 23 items and all the 23 items had a significant correlation (ρ Cutting Symptom Measure as translated in this study is a valid instrument. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. The Efficiency of Repressive Anti-Corruption Measures in Conditions of High-Level Corruption

    Directory of Open Access Journals (Sweden)

    Abramov Fedir V.

    2017-12-01

    Full Text Available The article is aimed at determining the efficiency of repressive anti-corruption measures in conditions of high-level corruption. It is shown that the formal rules regulating the use of repressive methods of countering corruption are characterized by a significant level of the target inefficiency of formal rules. Resulting from ignorance as to the causes of both occurence and spread of corruption – the inefficiency of the current formal rules – repressive anti-corruption measures are fundamentally incapable of achieving a significant reduction in the level of corruptness. It has been proved that, in addition to significant target inefficiency, repressive anti-corruption methods can potentially lead to increased levels of corruption because of abusing by supervisory officials of their official duties and the spread of internal corruption within anti-corruption structures. The potential threats from the uncontrolled anti-corruption structures towards other controlling organizations were considered. It is shown that in conditions of high-level corruption repressive anti-corruption measures can lead to expansion of imitation of anti-corruption activity.

  3. Noninvasive measurement of carboxyhemoglobin levels for adjustment of diffusion capacity measured during pulmonary function testing.

    Science.gov (United States)

    Mahoney, Anne M; Stimpson, Claudia L; Scott, Karen L; Hampson, Neil B

    2007-12-01

    The diffusing capacity of the lungs for carbon monoxide (D(LCO)) is commonly measured during pulmonary function testing (PFT). Although adjustment of the measured D(LCO) for an elevated baseline carboxyhemoglobin level is recommended, carboxyhemoglobin is not routinely measured, which may reduce the accuracy of D(LCO) measurements. We sought to assess the utility of routine carboxyhemoglobin measurement and subsequent D(LCO) correction in patients referred for PFT. We retrospectively reviewed 100 consecutive PFT results, including D(LCO) assessment. We used a pulse CO-oximeter (recently approved by the Food and Drug Administration) to noninvasively measure baseline carboxyhemoglobin (S(pCO)). We used simple descriptive statistics to compare the S(pCO) values. In subjects with elevated S(pCO) (> 2%) we adjusted the percent-of-predicted D(LCO). Interpretation of D(LCO) was categorized according to the American Thoracic Society classification scheme for respiratory impairment. The self-reported smokers had higher average S(pCO) than did self-reported nonsmokers (1.6% vs 3.5%, p carboxyhemoglobin is easy to perform during PFT. When precise measurement of D(LCO) is important, noninvasive measurement of carboxyhemoglobin may be of value. If routine S(pCO) measurement is considered, the highest yield is among current smokers.

  4. Online measurement of LHC beam parameters with the ATLAS High Level Trigger

    International Nuclear Information System (INIS)

    Strauss, E

    2012-01-01

    We present an online measurement of the LHC beamspot parameters in ATLAS using the High Level Trigger (HLT). When a significant change is detected in the measured beamspot, it is distributed to the HLT. There, trigger algorithms like b-tagging which calculate impact parameters or decay lengths benefit from a precise, up-to-date set of beamspot parameters. Additionally, online feedback is sent to the LHC operators in real time. The measurement is performed by an algorithm running on the Level 2 trigger farm, leveraging the high rate of usable events. Dedicated algorithms perform a full scan of the silicon detector to reconstruct event vertices from registered tracks. The distribution of these vertices is aggregated across the farm and their shape is extracted through fits every 60 seconds to determine the beamspot position, size, and tilt. The reconstructed beamspot values are corrected for detector resolution effects, measured in situ using the separation of vertices whose tracks have been split into two collections. Furthermore, measurements for individual bunch crossings have allowed for studies of single-bunch distributions as well as the behavior of bunch trains. This talk will cover the constraints imposed by the online environment and describe how these measurements are accomplished with the given resources. The algorithm tasks must be completed within the time constraints of the Level 2 trigger, with limited CPU and bandwidth allocations. This places an emphasis on efficient algorithm design and the minimization of data requests.

  5. Design of a dual-axis optoelectronic level for precision angle measurements

    International Nuclear Information System (INIS)

    Fan, Kuang-Chao; Wang, Tsung-Han; Lin, Sheng-Yi; Liu, Yen-Chih

    2011-01-01

    The accuracy of machine tools is mainly determined by angular errors during linear motion according to the well-known Abbe principle. Precision angle measurement is important to precision machines. This paper presents the theory and experiments of a new dual-axis optoelectronic level with low cost and high precision. The system adopts a commercial DVD pickup head as the angle sensor in association with the double-layer pendulum mechanism for two-axis swings, respectively. In data processing with a microprocessor, the measured angles of both axes can be displayed on an LCD or exported to an external PC. Calibrated by a triple-beam laser angular interferometer, the error of the dual-axis optoelectronic level is better than ±0.7 arcsec in the measuring range of ±30 arcsec, and the settling time is within 0.5 s. Experiments show the applicability to the inspection of precision machines

  6. Measurement of Salivary Resistin Level in Patients with Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Jinhua Yin

    2012-01-01

    Full Text Available Serum resistin was initially hypothesized as a link between obesity and insulin resistance in mice. The latest evidence suggests that serum resistin is proinflammatory cytokines. Inflammation plays a key role in the pathogenesis of type 2 diabetes mellitus (T2DM. Many reports have previously identified changed serum resistin levels in patients with T2DM, but little is known of the levels of resistin in saliva. In our study, saliva and serum samples were collected from 38 patients with newly diagnosed T2DM at each time point of OGTT and 35 nondiabetic controls at fasting state. Resistin concentrations were measured using ELISA. We have demonstrated the presence of resistin in saliva of T2DM and nondiabetic subjects. Saliva resistin levels of T2DM are significantly higher than those of nondiabetic controls. Resistin levels in saliva are not affected by eating activity and correlated with serum resistin levels at any time points of OGTT. A positive correlation of serum and salivary resistin with BMI and HOMA-IR existed in T2DM. Measurement of resistin in saliva is a simple, noninvasive and may be an acceptable alternative to blood sampling for evaluatinginflammation/obesity/insulin resistance state.

  7. Radon measurements during the building of a low-level laboratory

    CERN Document Server

    Antanasijevic, R; Bikit, I; Banjanac, R; Dragic, A; Joksimovic, D; Krmpotic, D; Udovicic, V; Vukovic, J

    1999-01-01

    Radon measurements were provided during the different stages of building of a low-level laboratory in Belgrade. The depth of the laboratory is 12 m, equivalent to 30 m of water with an area of 45 m sup 2. The whole of the laboratory is hermetically lined with 1 mm A1 foil and is ventilated with filtered air. Radon concentrations were measured with the CR-39 detector as well as via the gamma-ray spectroscopic measurements. The radon concentrations in the air were achieved to 20 Bqm sup - sup 3 and reduction of secondary and tertiary cosmic-ray fluxes is five times when ventilation, filtering and sealing was applied.

  8. Radon measurements during the building of a low-level laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Antanasijevic, R.; Anicin, I.; Bikit, I.; Banjanac, R.; Dragic, A.; Joksimovic, D.; Krmpotic, D.; Udovicic, V.; Vukovic, J

    1999-06-01

    Radon measurements were provided during the different stages of building of a low-level laboratory in Belgrade. The depth of the laboratory is 12 m, equivalent to 30 m of water with an area of 45 m{sup 2}. The whole of the laboratory is hermetically lined with 1 mm A1 foil and is ventilated with filtered air. Radon concentrations were measured with the CR-39 detector as well as via the gamma-ray spectroscopic measurements. The radon concentrations in the air were achieved to 20 Bqm{sup -3} and reduction of secondary and tertiary cosmic-ray fluxes is five times when ventilation, filtering and sealing was applied.

  9. Radon measurements during the building of a low-level laboratory

    International Nuclear Information System (INIS)

    Antanasijevic, R.; Anicin, I.; Bikit, I.; Banjanac, R.; Dragic, A.; Joksimovic, D.; Krmpotic, D.; Udovicic, V.; Vukovic, J.

    1999-01-01

    Radon measurements were provided during the different stages of building of a low-level laboratory in Belgrade. The depth of the laboratory is 12 m, equivalent to 30 m of water with an area of 45 m 2 . The whole of the laboratory is hermetically lined with 1 mm A1 foil and is ventilated with filtered air. Radon concentrations were measured with the CR-39 detector as well as via the gamma-ray spectroscopic measurements. The radon concentrations in the air were achieved to 20 Bqm -3 and reduction of secondary and tertiary cosmic-ray fluxes is five times when ventilation, filtering and sealing was applied

  10. Tracking of smokestack and cooling tower plumes using wind measurements at different levels

    International Nuclear Information System (INIS)

    Miller, R.L.; Patrinos, A.A.N.

    1980-08-01

    Relationships between cooling tower and smokestack plumes at the Bowen Electric Generating Plant in northwestern Georgia and wind direction measurements at levels from the surface at 850 mb (approx. 1.5 km) are examined. The wind measurements play an important role in estimating plume directions which in turn are utilized to establish control and target (upwind and downwind) areas for a study of plant-induced precipitation modification. Fifty-two plume observations were made during a three week period in December 1979. Results indicate that a windset (4.5 km from the plant) mounted at a level approximating that of the cooling tower plume is a better predictor of plume direction than surface windsets (1.0 km from the plant) or 850 mb level winds. However, an apparent topographical influence on the wind direction measurements at the plume-level windset site somewhat limits its plume tracking capability, at least for ambient winds from the SW quadrant

  11. Field-measured drag area is a key correlate of level cycling time trial performance

    Directory of Open Access Journals (Sweden)

    James E. Peterman

    2015-08-01

    Full Text Available Drag area (Ad is a primary factor determining aerodynamic resistance during level cycling and is therefore a key determinant of level time trial performance. However, Ad has traditionally been difficult to measure. Our purpose was to determine the value of adding field-measured Ad as a correlate of level cycling time trial performance. In the field, 19 male cyclists performed a level (22.1 km time trial. Separately, field-determined Ad and rolling resistance were calculated for subjects along with projected frontal area assessed directly (AP and indirectly (Est AP. Also, a graded exercise test was performed to determine $\\dot {V}{O}_{2}$V̇O2 peak, lactate threshold (LT, and economy. $\\dot {V}{O}_{2}$V̇O2 peak ($\\mathrm{l}~\\min ^{-1}$lmin−1 and power at LT were significantly correlated to power measured during the time trial (r = 0.83 and 0.69, respectively but were not significantly correlated to performance time (r = − 0.42 and −0.45. The correlation with performance time improved significantly (p < 0.05 when these variables were normalized to Ad. Of note, Ad alone was better correlated to performance time (r = 0.85, p < 0.001 than any combination of non-normalized physiological measure. The best correlate with performance time was field-measured power output during the time trial normalized to Ad (r = − 0.92. AP only accounted for 54% of the variability in Ad. Accordingly, the correlation to performance time was significantly lower using power normalized to AP (r = − 0.75 or Est AP (r = − 0.71. In conclusion, unless normalized to Ad, level time trial performance in the field was not highly correlated to common laboratory measures. Furthermore, our field-measured Ad is easy to determine and was the single best predictor of level time trial performance.

  12. Computed tomography measurements of the acetabulum in adult dysplastic hips: Which level is appropriate

    Energy Technology Data Exchange (ETDEWEB)

    Anda, S.; Kvistad, K.A. (Dept. of Radiology, Trondheim Univ. (Norway)); Terjesen, T. (Dept. of Orthopedic Surgery, Trondheim Univ. (Norway))

    1991-05-01

    A study has been performed to evaluate whether one or several levels are needed with comuted tomography (CT) study to provide sufficient information regarding anteversion and acetabular support to the femoral head. A total of 23 hips in 14 adults with uni- or bilateral congenital hip dysplasia (center-edge angle less than 20deg) were assessed by obtaining 5-mm contiguous CT slices and performing acetabular measurements at four levels. Both anterior and posterior acetabular supports as quantified by the anterior and posterior acetabular sector angles were significantly lower than normal at all levels. The sector angles increased in the proximal cuts, whereas the acetabular anteversin increased caudally. Because no important additional information was gained by measuring at different levels, we conclude that CT study at one level is sufficient for acetabular measurements and suggest that the slice through the center of the femoral head is the most appropriate one. (orig.).

  13. Authentication Assurance Level Application to the Inventory Sampling Measurement System

    International Nuclear Information System (INIS)

    Devaney, Mike M.; Kouzes, Richard T.; Hansen, Randy R.; Geelhood, Bruce D.

    2001-01-01

    This document concentrates on the identification of a standardized assessment approach for the verification of security functionality in specific equipment, the Inspection Sampling Measurement System (ISMS) being developed for MAYAK. Specifically, an Authentication Assurance Level 3 is proposed to be reached in authenticating the ISMS

  14. Apparatus to measure low level helium for neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ozaki, Shuji; Takao, Yoshiyuki; Muramasu, Masatomo; Hida, Tomoya; Sou, Hirofumi; Nakashima, Hideki [Kyushu Univ., Fukuoka (Japan); Kanda, Yukinori

    1998-03-01

    An apparatus to measure low level helium in a solid sample for neutron dosimetry in the practical use such as area monitoring in the long-term and reactor surveillance was reported. In our previous work, the helium atoms measurement system (HAMS) was developed. A sample was evaporated in the furnace and the released gas from the sample was analyzed with the mass spectrometer of the system to determine the amount of helium contained in it. The system has been improved to advance the lower helium measurement limit in a solid sample for its application to an area monitoring system. The mass of a solid is up to 100mg. Two important points should be considered to advance the lower limit. One was to produce a high quality vacuum in the system chamber for suppressing background gases during the sample measurement. The other important point was to detect very small output from the mass spectrometer. A pulse counting system was used to get high sensitivity in the mass 4 analyzing. (author)

  15. Radiation exposure rate and liquid level measurement inside a high level liquid waste (HLLW) storage tank

    International Nuclear Information System (INIS)

    Sur, B.; Yue, S.; Thekkevarriam, A.

    2007-01-01

    An instrument based on an inexpensive, small silicon diode has been developed and used to measure, for the first time, the gamma radiation exposure rate profile inside a 6.4 mm diameter reentrant thermo-well tube, immersed in the highly radioactive liquid solution in an HLLW storage tank. The measurement agrees with previous calculations of exposure rate, and provides confirmation for safe and effective radiation work plans and material selection for investigations and remediation of the storage tank facility. The measured radiation exposure rate profile is also used to confirm that the position of tank internal structures have not changed because of aging and corrosion, and to obtain, within a few mm, the level of liquid inside the tank. (author)

  16. Multiple levels and multiple challenges for measurement, reporting and verification of REDD+

    Directory of Open Access Journals (Sweden)

    Kaisa Korhonen-Kurki

    2013-08-01

    Full Text Available REDD+ is a multilevel endeavour. Global demands, national and subnational structures and local people’s needs and aspirations must all be linked in efforts to reduce emissions from deforestation and forest degradation. We use Brockhaus and Angelsen’s (2012 framework of Institutions, Interests, Information and Ideas (4Is to analyse the multilevel governance of REDD+ through one of its core elements: measurement, reporting and verification. We present the multilevel dimensions of REDD+ and the risks if they are disregarded. We analyse the flow and interplay of information, institutions and interests across levels in REDD+ measurement, reporting and verification and examine which multilevel governance mechanisms enable this flow. To support our analysis, we provide anecdotal evidence of challenges and opportunities from three countries: Brazil, Vietnam and Indonesia. Our analysis shows that it is essential to enhance and harmonize information flows between local and national levels for measurement, reporting and verification to be accountable. Furthermore, sound information flows between levels can increase the negotiation power of disadvantaged groups and ensure a more effective, efficient and equitable REDD+. To reduce the risk of conflict, REDD+ multilevel governance systems must match incentives and interests with transparent institutions. Effective multilevel governance mechanisms, such as novel cross-scale institutional arrangements, uniform regulations on the rights, responsibilities and procedures for monitoring information flows, and participation across levels, will provide tools for both information flow and greater matching of different interests across levels.

  17. Measurement of plasma neuropeptide Y levels with RIA in diabetic patients

    International Nuclear Information System (INIS)

    Cheng Guanghua; Zhang Xinlu; Yang Jun

    2002-01-01

    Objective: To investigate the clinical significance of the levels of plasma neuropeptide Y(NPY) in NIDDM patients with the occurrence of vascular complications. Methods: The plasma NPY levels were measured in 67 cases with DM (Group A: no Vascular complication, n = 38, Group B: with renal and retinal Vascular Changes, n = 29) and 37 normal subjects by radioimmunoassay. Results: NPY levels were higher in diabetic patients than those in normal subjects (p < 0.001). Also the plasma NPY levels were higher (p < 0.001) in diabetic patients with angiopathy (29 cases) than in those without it (38 cases). Conclusion: These data suggested that the changes of plasma NPY levels might be closely related to the occurrence and development of complications in DM patients

  18. Measurement of low levels of cesium-137 in water

    International Nuclear Information System (INIS)

    Milham, R.C.; Kantelo, M.V.

    1984-10-01

    Large volume water sampling systems were developed to measure very low levels of cesium-137 in river water and in finished water from water treatment plants. Three hundred to six hundred liters of filtered water are passed through the inorganic ion exchanger potassium cobalti-ferrocyanide to remove greater than 90% of the cesium. Measurement of cesium-137 by gamma ray spectrometry results in a sensitivity of 0.001 pCi/L. Portable as well as stationary samplers were developed to encompass a variety of applications. Results of a one year study of water from the Savannah River and from water treatment plants processing Savannah River water are presented. 3 references, 7 figures

  19. Measuring a Country's Product Ladder and Technology Level based on Trade Flow

    Directory of Open Access Journals (Sweden)

    Jong-il Kim

    2006-06-01

    Full Text Available This study tries to quantify the technology level of products based on the concept of product ladder. While many studies on country technology competitiveness use the aggregate indices such as total factor productivity and revealed comparative advantage, this study estimates the ranking of about 2000 products in product ladder by using SITC 5 digit level export data. Based on the product ladder, this study measures the country and industry ranking and explores the characteristics of the ranking. It provides the international comparison of inter-industry and intra-industry ranking differences in product ladder. The statistical relationships between the ranking in product ladder and the determinants of technology level such as R&D and physical capital investment and wage, confirms that the measured ranking in product ladder could be regarded as an indirect indicator of technology level. The product ladder is applied to the estimation of production function to see the effect of the product differentiation on labor productivity.

  20. Measurements of low-level prepulse on Nike KrF laser

    International Nuclear Information System (INIS)

    Karasik, Max; Mostovych, A.N.; Lehmberg, R.H.; Chan, Y.; Weaver, J.L.; Obenschain, S.P.

    2005-01-01

    The krypton fluoride (KrF) laser is a leading candidate driver for inertial fusion energy. Some of the current fusion target designs call for targets with thin metallic coatings. These targets could be particularly susceptible to preheat by a low-level laser prepulse. Knowledge of the prepulse can be important in understanding and modeling the behavior of such targets. This paper presents measurements of low-level prepulse on target with the Nike KrF laser. Sources of prepulse are discussed and measurements are performed under several specific laser conditions in order to evaluate the relative contribution of these sources to the overall prepulse. Prepulse is found to be ∼2x10 -7 from peak intensity for approximately 120 ns prior to the main laser pulse. Prepulse energy density on target is ∼2 J/cm 2 . The first laser amplifier in the time- and angle-multiplexed section of the laser is found to be the dominant source of prepulse

  1. Online Measurement of LHC Beam Parameters with the ATLAS High Level Trigger

    CERN Document Server

    Strauss, E; The ATLAS collaboration

    2011-01-01

    We present an online measurement of the LHC beam parameters in ATLAS using the High Level Trigger (HLT). When a significant change is detected in the measured beamspot, it is distributed to the HLT. There, trigger algorithms like b-tagging which calculate impact parameters or decay lengths benefit from a precise, up-to-date set of beamspot parameters. Additionally, online feedback is sent to the LHC operators in real time. The measurement is performed by an algorithm running on the Level 2 trigger farm, leveraging the high rate of usable events. Dedicated algorithms perform a full scan of the silicon detector to reconstruct event vertices from registered tracks. The distribution of these vertices is aggregated across the farm and their shape is extracted through fits every 60 seconds to determine the beamspot position, size, and tilt. The reconstructed beam values are corrected for detector resolution effects, measured in situ using the separation of vertices whose tracks have been split into two collections....

  2. Online measurement of LHC beam parameters with the ATLAS High Level Trigger

    CERN Document Server

    Strauss, E; The ATLAS collaboration

    2011-01-01

    We present an online measurement of the LHC beam parameters in ATLAS using the High Level Trigger (HLT). When a significant change is detected in the measured beamspot, it is distributed to the HLT. There, trigger algorithms like b-tagging which calculate impact parameters or decay lengths benefit from a precise,up-to-date set of beamspot parameters. Additionally, online feedback is sent to the LHC operators in real time. The measurement is performed by an algorithm running on the Level 2 trigger farm, leveraging the high rate of usable events. Dedicated algorithms perform a full scan of the silicon detector to reconstruct event vertices from registered tracks. The distribution of these vertices is aggregated across the farm and their shape is extracted through fits every 60 seconds to determine the beamspot position, size, and tilt. The reconstructed beam values are corrected for detector resolution effects, measured in situ using the separation of vertices whose tracks have been split into two collections. ...

  3. GPS water level measurements for Indonesia's Tsunami Early Warning System

    Directory of Open Access Journals (Sweden)

    T. Schöne

    2011-03-01

    Full Text Available On Boxing Day 2004, a severe tsunami was generated by a strong earthquake in Northern Sumatra causing a large number of casualties. At this time, neither an offshore buoy network was in place to measure tsunami waves, nor a system to disseminate tsunami warnings to local governmental entities. Since then, buoys have been developed by Indonesia and Germany, complemented by NOAA's Deep-ocean Assessment and Reporting of Tsunamis (DART buoys, and have been moored offshore Sumatra and Java. The suite of sensors for offshore tsunami detection in Indonesia has been advanced by adding GPS technology for water level measurements.

    The usage of GPS buoys in tsunami warning systems is a relatively new approach. The concept of the German Indonesian Tsunami Early Warning System (GITEWS (Rudloff et al., 2009 combines GPS technology and ocean bottom pressure (OBP measurements. Especially for near-field installations where the seismic noise may deteriorate the OBP data, GPS-derived sea level heights provide additional information.

    The GPS buoy technology is precise enough to detect medium to large tsunamis of amplitudes larger than 10 cm. The analysis presented here suggests that for about 68% of the time, tsunamis larger than 5 cm may be detectable.

  4. State-level high school completion rates: Concepts, measures, and trends.

    Directory of Open Access Journals (Sweden)

    John Robert Warren

    2005-12-01

    Full Text Available Since the mid 1970s the national rate at which incoming 9th graders have completed high school has fallen slowly but steadily; this is also true in 41 states. In 2002, about three in every four students who might have completed high school actually did so; in some states this figure is substantially lower. In this paper I review state-level measures of high school completion rates and describe and validate a new measure that reports these rates for 1975 through 2002. Existing measures based on the Current Population Survey are conceptually imperfect and statistically unreliable. Measures based on Common Core Data (CCD dropout information are unavailable for many states and have different conceptual weaknesses. Existing measures based on CCD enrollment and completion data are systematically biased by migration, changes in cohort size, and/or grade retention. The new CCD-based measure described here is considerably less biased, performs differently in empirical analyses, and gives a different picture of the dropout situation across states and over time.

  5. Development of radiation detection and measurement systems - Development of level gauge and density gauge

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Su Man; Kim, Sung Hun; Jang, Jung Hun; Yun, Mung Hun; Yun Jun Hyung; Kang, Sung Youn [Techvalley co., Ltd., Research Center, Seoul (Korea)

    2000-03-01

    -Pervasive effect of R and D results. Technical development of level/density measuring instruments has a definitely significant effect on the quality test of various products in the filled on the heavy industry. As measurement of flow increasingly becomes important in the plant design in the chemical industry, development of our products is applicable to various equipment in the field of industries. -Applications of R and D results. Technical development of level/density measurement copes with a technical difficulty in inspecting the internal conditions of chemical plants by transmission through metal materials in a non-destructive manner and thereby enables non-destructive flow and level tests in the field of industries. 11 refs., 19 figs., 4 tabs. (Author)

  6. The Efficiency of Repressive Anti-Corruption Measures in Conditions of High-Level Corruption

    OpenAIRE

    Abramov Fedir V.

    2017-01-01

    The article is aimed at determining the efficiency of repressive anti-corruption measures in conditions of high-level corruption. It is shown that the formal rules regulating the use of repressive methods of countering corruption are characterized by a significant level of the target inefficiency of formal rules. Resulting from ignorance as to the causes of both occurence and spread of corruption – the inefficiency of the current formal rules – repressive anti-corruption measures are fundamen...

  7. Proficiency testing criteria for clearance level in solid waste gamma measurement in Taiwan.

    Science.gov (United States)

    Chen, Chun-Liang; Wang, Jeng-Jong; Chiu, Huang-Sheng

    2013-11-01

    To guarantee the measurement quality for clearance level in solid waste material, the Institute of Nuclear Energy Research (INER) established the criteria for proficiency testing of clearance level measurement. INER and the Taiwan Accreditation Foundation (TAF) organized the Technique Committee Meeting twice to discuss these criteria in 2011. The participating laboratories must completely conform to the ISO/IEC 17025, and they also must meet the requirements of the criteria. According to the criteria, the participating laboratories analyzed the minimum detectable amount (MDA) and that should be less than 20% of the clearance level (AMDA) given in the Atomic Energy Council's (AEC) "Regulations on Clearance Level for Radioactive Waste Management". The testing results should conform to the deviation and traceability requirements. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Long-Period Fiber Grating Sensors for the Measurement of Liquid Level and Fluid-Flow Velocity

    Directory of Open Access Journals (Sweden)

    Jian-Neng Wang

    2012-04-01

    Full Text Available This paper presents the development and assessment of two types of Long Period Fiber Grating (LPFG-based sensors including a mobile liquid level sensor and a reflective sensor for the measurement of liquid level and fluid-flow velocity. Shewhart control charts were used to assess the liquid level sensing capacity and reliability of the mobile CO2-laser engraved LPFG sensor. There were ten groups of different liquid level experiment and each group underwent ten repeated wavelength shift measurements. The results showed that all measurands were within the control limits; thus, this mobile sensor was reliable and exhibited at least 100-cm liquid level measurement capacity. In addition, a reflective sensor consisting of five LPFGs in series with a reflective end has been developed to evaluate the liquid level and fluid-flow velocity. These five LPFGs were fabricated by the electrical arc discharge method and the reflective end was coated with silver by Tollen’s test. After each liquid level experiment was performed five times, the average values of the resonance wavelength shifts for LPFG Nos. 1–5 were in the range of 1.35–9.14 nm. The experimental findings showed that the reflective sensor could be used to automatically monitor five fixed liquid levels. This reflective sensor also exhibited at least 100-cm liquid level measurement capacity. The mechanism of the fluid-flow velocity sensor was based on analyzing the relationship among the optical power, time, and the LPFG’s length. There were two types of fluid-flow velocity measurements: inflow and drainage processes. The differences between the LPFG-based fluid-flow velocities and the measured average fluid-flow velocities were found in the range of 8.7–12.6%. For the first time to our knowledge, we have demonstrated the feasibility of liquid level and fluid-flow velocity sensing with a reflective LPFG-based sensor without modifying LPFGs or coating chemical compounds.

  9. Long-Period Fiber Grating Sensors for the Measurement of Liquid Level and Fluid-Flow Velocity

    Science.gov (United States)

    Wang, Jian-Neng; Luo, Ching-Ying

    2012-01-01

    This paper presents the development and assessment of two types of Long Period Fiber Grating (LPFG)-based sensors including a mobile liquid level sensor and a reflective sensor for the measurement of liquid level and fluid-flow velocity. Shewhart control charts were used to assess the liquid level sensing capacity and reliability of the mobile CO2-laser engraved LPFG sensor. There were ten groups of different liquid level experiment and each group underwent ten repeated wavelength shift measurements. The results showed that all measurands were within the control limits; thus, this mobile sensor was reliable and exhibited at least 100-cm liquid level measurement capacity. In addition, a reflective sensor consisting of five LPFGs in series with a reflective end has been developed to evaluate the liquid level and fluid-flow velocity. These five LPFGs were fabricated by the electrical arc discharge method and the reflective end was coated with silver by Tollen's test. After each liquid level experiment was performed five times, the average values of the resonance wavelength shifts for LPFG Nos. 1–5 were in the range of 1.35–9.14 nm. The experimental findings showed that the reflective sensor could be used to automatically monitor five fixed liquid levels. This reflective sensor also exhibited at least 100-cm liquid level measurement capacity. The mechanism of the fluid-flow velocity sensor was based on analyzing the relationship among the optical power, time, and the LPFG's length. There were two types of fluid-flow velocity measurements: inflow and drainage processes. The differences between the LPFG-based fluid-flow velocities and the measured average fluid-flow velocities were found in the range of 8.7–12.6%. For the first time to our knowledge, we have demonstrated the feasibility of liquid level and fluid-flow velocity sensing with a reflective LPFG-based sensor without modifying LPFGs or coating chemical compounds. PMID:22666046

  10. Long-period fiber grating sensors for the measurement of liquid level and fluid-flow velocity.

    Science.gov (United States)

    Wang, Jian-Neng; Luo, Ching-Ying

    2012-01-01

    This paper presents the development and assessment of two types of Long Period Fiber Grating (LPFG)-based sensors including a mobile liquid level sensor and a reflective sensor for the measurement of liquid level and fluid-flow velocity. Shewhart control charts were used to assess the liquid level sensing capacity and reliability of the mobile CO(2)-laser engraved LPFG sensor. There were ten groups of different liquid level experiment and each group underwent ten repeated wavelength shift measurements. The results showed that all measurands were within the control limits; thus, this mobile sensor was reliable and exhibited at least 100-cm liquid level measurement capacity. In addition, a reflective sensor consisting of five LPFGs in series with a reflective end has been developed to evaluate the liquid level and fluid-flow velocity. These five LPFGs were fabricated by the electrical arc discharge method and the reflective end was coated with silver by Tollen's test. After each liquid level experiment was performed five times, the average values of the resonance wavelength shifts for LPFG Nos. 1-5 were in the range of 1.35-9.14 nm. The experimental findings showed that the reflective sensor could be used to automatically monitor five fixed liquid levels. This reflective sensor also exhibited at least 100-cm liquid level measurement capacity. The mechanism of the fluid-flow velocity sensor was based on analyzing the relationship among the optical power, time, and the LPFG's length. There were two types of fluid-flow velocity measurements: inflow and drainage processes. The differences between the LPFG-based fluid-flow velocities and the measured average fluid-flow velocities were found in the range of 8.7-12.6%. For the first time to our knowledge, we have demonstrated the feasibility of liquid level and fluid-flow velocity sensing with a reflective LPFG-based sensor without modifying LPFGs or coating chemical compounds.

  11. Precision lifetime measurements of Ar II 4p doublet levels

    International Nuclear Information System (INIS)

    Marger, D.; Schmoranzer, H.

    1990-01-01

    The lifetimes of the Ar II 4p doublet fine-structure levels 4p 2 D 0 5/2 , 4p' 2 F 0 5/2 and 4p' 2 F 0 7/2 were measured by beam-dye laser spectroscopy. The experimental uncertainty was reduced to below 1%. (orig.)

  12. Power levels in office equipment: Measurements of new monitors and personal computers

    International Nuclear Information System (INIS)

    Roberson, Judy A.; Brown, Richard E.; Nordman, Bruce; Webber, Carrie A.; Homan, Gregory H.; Mahajan, Akshay; McWhinney, Marla; Koomey, Jonathan G.

    2002-01-01

    Electronic office equipment has proliferated rapidly over the last twenty years and is projected to continue growing in the future. Efforts to reduce the growth in office equipment energy use have focused on power management to reduce power consumption of electronic devices when not being used for their primary purpose. The EPA ENERGY STAR[registered trademark] program has been instrumental in gaining widespread support for power management in office equipment, and accurate information about the energy used by office equipment in all power levels is important to improving program design and evaluation. This paper presents the results of a field study conducted during 2001 to measure the power levels of new monitors and personal computers. We measured off, on, and low-power levels in about 60 units manufactured since July 2000. The paper summarizes power data collected, explores differences within the sample (e.g., between CRT and LCD monitors), and discusses some issues that arise in m etering office equipment. We also present conclusions to help improve the success of future power management programs.Our findings include a trend among monitor manufacturers to provide a single very low low-power level, and the need to standardize methods for measuring monitor on power, to more accurately estimate the annual energy consumption of office equipment, as well as actual and potential energy savings from power management

  13. Attempts to develop a new nuclear measurement technique of β-glucuronidase levels in biological samples

    International Nuclear Information System (INIS)

    Unak, T.; Avcibasi, U.; Yildirim, Y.; Cetinkaya, B.

    2003-01-01

    β-Glucuronidase is one of the most important hydrolytic enzymes in living systems and plays an essential role in the detoxification pathway of toxic materials incorporated into the metabolism. Some organs, especially liver and some tumour tissues, have high level of β-glucuronidase activity. As a result the enzymatic activity of some kind of tumour cells, the radiolabelled glucuronide conjugates of cytotoxic, as well as radiotoxic compounds have potentially very valuable diagnostic and therapeutic applications in cancer research. For this reason, a sensitive measurement of β-glucuronidase levels in normal and tumour tissues is a very important step for these kinds of applications. According to the classical measurement method of β-glucuronidase activity, in general, the quantity of phenolphthalein liberated from its glucuronide conjugate, i.e. phenolphthalein-glucuronide, by β-glucuronidase has been measured by use of the spectrophotometric technique. The lower detection limit of phenolphthalein by the spectrophotometric technique is about 1-3 mg. This means that the β-glucuronidase levels could not be detected in biological samples having lower levels of β-glucuronidase activity and therefore the applications of the spectrophotometric technique in cancer research are very seriously limited. Starting from this consideration, we recently attempted to develop a new nuclear technique to measure much lower concentrations of β-glucuronidase in biological samples. To improve the detection limit, phenolphthalein-glucuronide and also phenyl-N-glucuronide were radioiodinated with 131 I and their radioactivity was measured by use of the counting technique. Therefore, the quantity of phenolphthalein or aniline radioiodinated with 131 I and liberated by the deglucuronidation reactivity of β-glucuronidase was used in an attempt to measure levels lower than the spectrophotometric measurement technique. The results obtained clearly verified that 0.01 pg level of

  14. Measurement of millisecond half-lives of isomeric levels in some nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Garg, K C; Khurana, C S [Punjabi Univ., Patiala (India). Nuclear Science Labs.

    1976-09-01

    Half-lives of 2.7, 14.5, 17, 20, 20.4, 44 and 2230 msec, of isomeric levels in /sup 208/Bi, /sup 88/Y, /sup 75/As, /sup 24/Na, /sup 71/Ge, /sup 114/In and /sup 167/Er respectively have been measured, employing on-line irradiation system. These millisecond isomeric levels are produced by 14.7 MeV neutrons through (n,p), (n,..cap alpha..), (n,n') and (n,2n) reactions on natural target samples. A ..gamma..-ray scintillation detector coupled with NTA-512B, 1024 channel analyzer has been used to follow the decay of the millisecond activities. Deflected deuteron beam bursts have been used to reduce the long-time background to initial count ratios in the decay curves to achieve a better accuracy of measurements.

  15. Interference pattern period measurement at picometer level

    Science.gov (United States)

    Xiang, Xiansong; Wei, Chunlong; Jia, Wei; Zhou, Changhe; Li, Minkang; Lu, Yancong

    2016-10-01

    To produce large scale gratings by Scanning Beam Interference Lithography (SBIL), a light spot containing grating pattern is generated by two beams interfering, and a scanning stage is used to drive the substrate moving under the light spot. In order to locate the stage at the proper exposure positions, the period of the Interference pattern must be measured accurately. We developed a set of process to obtain the period value of two interfering beams at picometer level. The process includes data acquisition and data analysis. The data is received from a photodiode and a laser interferometer with sub-nanometer resolution. Data analysis differs from conventional analyzing methods like counting wave peaks or using Fourier transform to get the signal period, after a preprocess of filtering and envelope removing, the mean square error is calculated between the received signal and ideal sinusoid waves to find the best-fit frequency, thus an accuracy period value is acquired, this method has a low sensitivity to amplitude noise and a high resolution of frequency. With 405nm laser beams interfering, a pattern period value around 562nm is acquired by employing this process, fitting diagram of the result shows the accuracy of the period value reaches picometer level, which is much higher than the results of conventional methods.

  16. Solar Modulation of Atmospheric Cosmic Radiation:. Comparison Between In-Flight and Ground-Level Measurements

    Science.gov (United States)

    Iles, R. H. A.; Taylor, G. C.; Jones, J. B. L.

    January 2000 saw the start of a collaborative study involving the Mullard Space Science Laboratory, Virgin Atlantic Airways, the Civil Aviation Authority and the National Physical Laboratory in a program to investigate the cosmic radiation exposure to aircrew. The study has been undertaken in view of EU Directive 96/291 (May 2000) which requires the assessment of the level of radiation exposure to aircrew. The project's aims include validation of radiation dose models and evaluation of space weather effects on atmospheric cosmic radiation levels, in particular those effects not accounted for by the models. Ground level measurements are often used as a proxy for variations in cosmic radiation dose levels at aircraft altitudes, especially during Forbush Decreases (FDs) and Solar Energetic Particle (SEP) events. Is this estimation realistic and does the ground level data accurately represent what is happening at altitude? We have investigated the effect of a FD during a flight from Hong Kong to London Heathrow on the 15th July 2000 and compared count rate and dose measurements with simultaneous variations measured at ground level. We have also compared the results with model outputs.

  17. Franck--Hertz experiment with higher excitation level measurements

    International Nuclear Information System (INIS)

    Liu, F.H.

    1987-01-01

    The measurement of the higher levels of 6 3 P 2 and 6 1 P 1 of the mercury atom in the Franck--Hertz experiment has been introduced into the junior and senior laboratory course by using a homemade tetrode Franck--Hertz tube. The main structure of the tube is described. The optimum operating conditions are in the temperature range between 130 and 150 0 C and the collector currents are of the order of 10 -9 A. The additional observations of the famous Franck--Hertz experiment in the laboratory course will give the students more familiarity with the quantum behavior of atoms

  18. A Float Type Liquid Level Measuring System Using a Modified Inductive Transducer

    Directory of Open Access Journals (Sweden)

    Samik MARICK

    2014-11-01

    Full Text Available Float type liquid level sensor is generally used as a very simple technique for local level indication and level switching. In the present paper a technique has been proposed to transmit the measured liquid level signal of a float type sensor at remote terminal using a modified differential inductance type electromechanical transducer. The theoretical characteristic equation of this transducer has been derived. A prototype unit of the transducer has been developed and fabricated and its performance characteristic has been experimentally determined. The experimental results are reported in the paper. From experimental data, a very good linear characteristic of the proposed level transducer has been observed.

  19. Measurement of water potential in low-level waste management

    International Nuclear Information System (INIS)

    Jones, T.L.; Gee, G.W.; Kirkham, R.R.; Gibson, D.D.

    1982-08-01

    The measurement of soil water is important to the shallow land burial of low-level waste. Soil water flow is the principle mechanism of radionuclide transport, allows the establishment of stabilizing vegetation and also governs the dissolution and release rates of the waste. This report focuses on the measurement of soil water potential and provides an evaluation of several field instruments that are available for use to monitor waste burial sites located in arid region soils. The theoretical concept of water potential is introduced and its relationship to water content and soil water flow is discussed. Next, four major areas of soils research are presented in terms of their dependence on the water potential concept. There are four basic types of sensors used to measure soil water potential. These are: (1) tensiometers; (2) soil psychrometers; (3) electrical resistance blocks; and (4) heat dissipation probes. Tensiometers are designed to measure the soil water potential directly by measuring the soil water pressure. Monitoring efforts at burial sites require measurements of soil water over long time periods. They also require measurements at key locations such as waste-soil interfaces and within any barrier system installed. Electrical resistance blocks are well suited for these types of measurements. The measurement of soil water potential can be a difficult task. There are several sensors commercially available; however, each has its own limitations. It is important to carefully select the appropriate sensor for the job. The accuracy, range, calibration, and stability of the sensor must be carefully considered. This study suggests that for waste management activities, the choice of sensor will be the tensiometer for precise soil characterization studies and the electrical resistance block for long term monitoring programs

  20. Accurate Fluid Level Measurement in Dynamic Environment Using Ultrasonic Sensor and ν-SVM

    Directory of Open Access Journals (Sweden)

    Jenny TERZIC

    2009-10-01

    Full Text Available A fluid level measurement system based on a single Ultrasonic Sensor and Support Vector Machines (SVM based signal processing and classification system has been developed to determine the fluid level in automotive fuel tanks. The novel approach based on the ν-SVM classification method uses the Radial Basis Function (RBF to compensate for the measurement error induced by the sloshing effects in the tank caused by vehicle motion. A broad investigation on selected pre-processing filters, namely, Moving Mean, Moving Median, and Wavelet filter, has also been presented. Field drive trials were performed under normal driving conditions at various fuel volumes ranging from 5 L to 50 L to acquire sample data from the ultrasonic sensor for the training of SVM model. Further drive trials were conducted to obtain data to verify the SVM results. A comparison of the accuracy of the predicted fluid level obtained using SVM and the pre-processing filters is provided. It is demonstrated that the ν-SVM model using the RBF kernel function and the Moving Median filter has produced the most accurate outcome compared with the other signal filtration methods in terms of fluid level measurement.

  1. Present status and prospects of ultralow level radioactivity measurements (5). Measurement of time variations of cosmic rays in the past by the detection of ultralow level 14C and 7Be radioactivity

    International Nuclear Information System (INIS)

    Sakurai, Hirohisa

    2006-01-01

    The change of the concentration of 7 Be in air and 14 C in the tree ring, cosmogenic nuclide, was measured by the ultralow level radioactivity measurement method. The concentration of 14 C in the tree ring was changed by the intensity of cosmic ray in the past. Cosmic ray and cosmogenic nuclide, solar activity and change of cosmic ray intensity, the continuous measurement of 7 Be concentration in atmosphere, and measurement of 14 C concentration in the old tree ring are reported. 14 C concentration in tree ring is measured by the ultralow level liquid scintillation measuring system (Quantulus) and 14 C concentration in the tree ring of Japanese cedar at Akita and Murou was changed by nuclear tests in air. 14 C concentration of Chokaijindaisugi, cryptomeria, about 2500 years old, is changed periodically about 10.1 years as almost same as the sunspot activity cycle. (S.Y.)

  2. One method of measure low activity level of α, β

    International Nuclear Information System (INIS)

    Sun Shimin

    2003-01-01

    In this paper it is described that several method of measure low activity level of Alpha and Beta, and an circuit diagram for signal of Alpha and Beta to differentiate with method of wave shape identification. With the method, the signal of Beta did not interfere any signal to the count-way of Alpha. For adopted the technology the model JA-3502 of eight detectors of low background Alpha and Beta measuring instrument only have 2.65 x 10 -4 cpm/cm 2 background count rate at count-way of Alpha. Opposite the model FJ-2600 middle area low background Alpha and Beta measuring instrument have 1.27 x 10 -3 cpm/cm 2 background count rate at count-way of Alpha. The latter is 5 times of other

  3. Design, Development and Testing of a Semi Cylindrical Capacitive Sensor for Liquid Level Measurement

    Directory of Open Access Journals (Sweden)

    Sagarika PAL

    2010-05-01

    Full Text Available In the present paper a low cost noncontact semi cylindrical capacitive type liquid level sensor has been designed, developed and tested. The semi cylindrical capacitive sensor consisting of two thin semi cylindrical metal plates separated by a gap distance and mounted around a non conducting storage tank, has been used to measure the liquid level in the tank. The measured capacitance variation with variation of liquid level is linear and obtained in the nano farad range which again has been converted into voltage variation by using proper signal conditioning circuit. Since the sensor is noncontact type it can be used for both conducting and non conducting type of liquid contained within a non conducting tank. For converting the capacitance variation in to voltage variation a series R-L-C resonating circuit has been used instead of conventional bridge circuit. Experimental results confirm the satisfactory performance of the sensor for liquid level measurement.

  4. Application of geometry correction factors for low-level waste package dose measurements. Revision 1

    International Nuclear Information System (INIS)

    Chandler, M.C.; Parish, B.

    1995-01-01

    Plans are to determine the Cs-137 content of low-level waste packages generated in High-Level Waste by measuring the radiation level at a specified distance from the package with a hand-held radiation instrument. The measurement taken at this specified distance, either 3 or 5 feet, is called the far-field measurement. This report documents a method for adjusting the gamma exposure rate (mR/hr) reading used in dose-to-curie determinations when the far-field measurement equals the background reading. This adjustment is necessary to reduce the conservatism resulting from using a minimum detection limit exposure rate for the dose-to-curie determination for the far-field measurement position. To accomplish this adjustment, the near-field (5 cm) measurement is multiplied by a geometry correction factor to obtain an estimate of the far field exposure rate (which is below instrument sensitivity). This estimate of the far field exposure rate is used to estimate the Cs-137 curie content of the package. This report establishes the geometry correction factors for the dose-to-curie determination when the far-field gamma exposure measurement equals the background reading. This report also provides a means of demonstrating compliance to 1S Manual requirements for exposure rate readings at different locations from waste packages while specifying only two measurement positions. This demonstration of compliance is necessary to minimize the number of locations exposure rate measurements that are required, i.e., ALARA

  5. The Levels of Emotional Awareness Scale: a cognitive-developmental measure of emotion.

    Science.gov (United States)

    Lane, R D; Quinlan, D M; Schwartz, G E; Walker, P A; Zeitlin, S B

    1990-01-01

    The Levels of Emotional Awareness Scale (LEAS) is based on a new cognitive-developmental model of emotional experience. The scale poses evocative interpersonal situations and elicits descriptions of the emotional responses of self and others which are scored using specific structural criteria. Forty undergraduates (20 of each sex) were tested. Interrater reliability and intratest homogeneity of the LEAS were strong. The LEAS was significantly correlated with two measures of maturity: the Washington University Sentence Completion Test (SCT) of Ego Development, and the Parental Descriptions Scale-a cognitive-developmental measure of object representation. In addition, the LEAS correlated positively with openness to experience and emotional range but not with measures of specific emotions, repression or the number of words used in the LEAS responses. These findings suggest that it is the level of emotion, not the specific quality of emotion, that is tapped by the LEAS.

  6. Measurement of Responsibility: A Critical Evaluation of Level of Work Measurement by Time-Span of Discretion.

    Science.gov (United States)

    Laner, S.; And Others

    This report is a critical evaluation based on extended field trials and theoretical analysis of the time-span technique of measuring level of work in organizational hierarchies. It is broadly concluded that the technique does possess many of the desirable features claimed by its originator, but that earlier, less highly structured versions based…

  7. Does level of specificity affect measures of motivation to comply? A randomized evaluation.

    Science.gov (United States)

    Branscum, Paul; Senkowski, Valerie

    2018-05-30

    The theory of planned behavior (TPB) is a popular value-expectancy model in social and behavioral health. Motivation to comply, one of the theory's constructs, has not been well operationalized and measured in the past, and to date, there has been no assessment of whether level of specificity affects the measurement of the construct. The purpose of this study was to measure the motivation to comply construct across four domains (from general to TACT-behavior specific) and evaluate the potential impact the differences have when identifying determinants of generalized injunctive norms. Students (n = 234) attending a large southwestern university completed a TPB survey related to sleep and physical activity, and were randomized to one of four domains that measured motivation to comply (General domain, n = 58; Health domain, n = 60; Behavioral domain, n = 56; and TACT domain, n = 60). Across both behaviors, motivation to comply measurements did not appear to be affected by changing the level of specificity. Referents for sleep and physical activity were mostly significant, but the effects were small to medium. Future researchers should consider removing motivation to comply measures from TPB surveys to reduce respondent burden or find alternative ways of measuring the construct.

  8. Measurement and evaluation of the external radiation level at reactor Kartini

    International Nuclear Information System (INIS)

    Atok Suhartanto; Suparno

    2013-01-01

    Measurement and evaluation of external radiation level at reactor Kartini in 2012 has been done. The purpose of this activity is to know the external radiation level as a result of the radioactive or radiation source usage, toward the operational of limit condition. The measurement is using survey meter Inspector 11086, factor of calibration 0.991 mR/h, at 9 locations is: Control room area, Thermal column facilities, Demineralizer, Beamport radiography facilities, bulk shielding Deck, Subcritical facilities, Reactor hall, Deck reactor and on the surface of reactor water tank . The highest room average measurement result in 9 working areas for 12 months continuously are at the reactor tank location is between 13.05±1.09 (xlO -2 mSv/hour) to 16.80±1.40 (x10 -2 mSv/hour), and the lowest measurement result in 1 location (control room) is 0.02±0.005 (x10 -2 mSv/hour) to 0.035±0.009 (x10 -2 mSv/hour). The Kartini reactor is involved in the control area which has potentially contaminated and has radiation exposure at the level of 6 mSv/year. Radiation Protection Officer that work in interval will received radiation exposure dosage of 8.4 mSv/year. This dosage is still below the Below Dosage Value which is recommended by, BAPETEN decree No, 4, 2013 about Protection and Radiation Safety in Nuclear Energy Application at 20 mSv/year. The result of the evaluation above shows that the external radiation which occurred in each area is still below the operational of limit condition that is written on the Kartini reactor safety analysis report, on document number: C7/05/B2/LAK/2010, revision 7. So that the workplace is safe for work monitored. (author)

  9. Measurement of liquid level in a natural circulation circuit using an ultrasonic technique

    International Nuclear Information System (INIS)

    Barbosa, Amanda Cardozo; Su, Jian

    2017-01-01

    The measurement by an ultrasonic technique of the water level in the expansion tank of the Natural Circulation Circuit (NCC) of the Experimental Thermo-Hydraulic Laboratory of the Institute of Nuclear Engineering is presented. In the single-phase NCC operation the water level in the expansion tank is stable. However, during the two-phase operation, oscillations occur in the water level due to temperature and vacuum fraction variations. Thus, the development of a technique that allows the measurement of these oscillations, will allow an estimation of the variation of the vacuum fraction of the circuit over time. The experimental set - up was performed on a test bench, using an ultrasonic transducer. The ultrasonic technique used is pulse-echo, in which the same transducer is the transmitter and receiver of the signal. The transducer-shoe assembly is part of an ultrasonic system consisting of an ultrasonic signal generating plate, transducers and a computer (PC) with a program in LabView to control the system. The program is able to calculate the transit time that the ultrasonic signals take to cross the tank base wall, the layer (level) of liquid and return to the transducer. Knowing the speed of the ultrasound in the wall and in the liquid it is possible to calculate the thickness of the wall and the height of the liquid. Measurements were made by filling the tank with a known volume of water and under varying temperature conditions, from room temperature to 90 deg C. The liquid heights are determined and the volume of water calculated by measuring the temperature with a digital thermometer. The volumes measured were highly accurate when compared to the known volumes

  10. Effects of Barometric Fluctuations on Well Water-Level Measurements and Aquifer Test Data

    Energy Technology Data Exchange (ETDEWEB)

    FA Spane, Jr.

    1999-12-16

    The Pacific Northwest National Laboratory, as part of the Hanford Groundwater Monitoring Project, examines the potential for offsite migration of contamination within underlying aquifer systems. Well water-level elevation measurements from selected wells within these aquifer systems commonly form the basis for delineating groundwater-flow patterns (i.e., flow direction and hydraulic gradient). In addition, the analysis of water-level responses obtained in wells during hydrologic tests provides estimates of hydraulic properties that are important for evaluating groundwater-flow velocity and transport characteristics. Barometric pressure fluctuations, however, can have a discernible impact on well water-level measurements. These barometric effects may lead to erroneous indications of hydraulic head within the aquifer. Total hydraulic head (i.e., sum of the water-table elevation and the atmospheric pressure at the water-table surface) within the aquifer, not well water-level elevation, is the hydrologic parameter for determining groundwater-flow direction and hydraulic gradient conditions. Temporal variations in barometric pressure may also adversely affect well water-level responses obtained during hydrologic tests. If significant, adjustments or removal of these barometric effects from the test-response record may be required for quantitative hydraulic property determination. This report examines the effects of barometric fluctuations on well water-level measurements and evaluates adjustment and removal methods for determining areal aquifer head conditions and aquifer test analysis. Two examples of Hanford Site unconfined aquifer tests are examined that demonstrate barometric response analysis and illustrate the predictive/removal capabilities of various methods for well water-level and aquifer total head values. Good predictive/removal characteristics were demonstrated with best corrective results provided by multiple-regression deconvolution methods.

  11. Measuring situational awareness and resolving inherent high-level fusion obstacles

    Science.gov (United States)

    Sudit, Moises; Stotz, Adam; Holender, Michael; Tagliaferri, William; Canarelli, Kathie

    2006-04-01

    Information Fusion Engine for Real-time Decision Making (INFERD) is a tool that was developed to supplement current graph matching techniques in Information Fusion models. Based on sensory data and a priori models, INFERD dynamically generates, evolves, and evaluates hypothesis on the current state of the environment. The a priori models developed are hierarchical in nature lending them to a multi-level Information Fusion process whose primary output provides a situational awareness of the environment of interest in the context of the models running. In this paper we look at INFERD's multi-level fusion approach and provide insight on the inherent problems such as fragmentation in the approach and the research being undertaken to mitigate those deficiencies. Due to the large variance of data in disparate environments, the awareness of situations in those environments can be drastically different. To accommodate this, the INFERD framework provides support for plug-and-play fusion modules which can be developed specifically for domains of interest. However, because the models running in INFERD are graph based, some default measurements can be provided and will be discussed in the paper. Among these are a Depth measurement to determine how much danger is presented by the action taking place, a Breadth measurement to gain information regarding the scale of an attack that is currently happening, and finally a Reliability measure to tell the user the credibility of a particular hypothesis. All of these results will be demonstrated in the Cyber domain where recent research has shown to be an area that is welldefined and bounded, so that new models and algorithms can be developed and evaluated.

  12. Two-level Robust Measurement Fusion Kalman Filter for Clustering Sensor Networks

    Institute of Scientific and Technical Information of China (English)

    ZHANG Peng; QI Wen-Juan; DENG Zi-Li

    2014-01-01

    This paper investigates the distributed fusion Kalman filtering over clustering sensor networks. The sensor network is partitioned as clusters by the nearest neighbor rule and each cluster consists of sensing nodes and cluster-head. Using the minimax robust estimation principle, based on the worst-case conservative system with the conservative upper bounds of noise variances, two-level robust measurement fusion Kalman filter is presented for the clustering sensor network systems with uncertain noise variances. It can significantly reduce the communication load and save energy when the number of sensors is very large. A Lyapunov equation approach for the robustness analysis is presented, by which the robustness of the local and fused Kalman filters is proved. The concept of the robust accuracy is presented, and the robust accuracy relations among the local and fused robust Kalman filters are proved. It is proved that the robust accuracy of the two-level weighted measurement fuser is equal to that of the global centralized robust fuser and is higher than those of each local robust filter and each local weighted measurement fuser. A simulation example shows the correctness and effectiveness of the proposed results.

  13. Recoil distance measurements of litetimes of levels in 2120F and 16N

    International Nuclear Information System (INIS)

    Kozub, R.L.; Mateja, J.F.; Lin, J.; Lister, C.J.; Olness, J.; Warburton, E.K.; Bynum, M.R.; Matthews, T.L.

    1981-01-01

    The previously-reported measurements of meanlives of 20 21 F levels using the recoil-distance method (RDM) and 18 O + 7 Li reactions have been repeated using improved experimental techniques. In addition, the lifetimes of two 16 N levels were measured, using the same experimental setup and 11 B + 7 Li reactions. Data were taken using the BNL precision plunger, in which were mounted a stretched Ta stopper foil (approx. 20 /sub cm 2 //sup mg/ thick) and a 300 μg/cm 2 - thick Li target condensed onto a stretched, 1.4 mg/cm 2 - thick Ta backing. Changes in target-to-stopper distance (d) could be controlled to an accuracy of about +- 1 μm, and were monitored by measuring target-to-stopper capacitance

  14. Lanthanide complexes as luminogenic probes to measure sulfide levels in industrial samples

    International Nuclear Information System (INIS)

    Thorson, Megan K.; Ung, Phuc; Leaver, Franklin M.; Corbin, Teresa S.; Tuck, Kellie L.; Graham, Bim; Barrios, Amy M.

    2015-01-01

    A series of lanthanide-based, azide-appended complexes were investigated as hydrogen sulfide-sensitive probes. Europium complex 1 and Tb complex 3 both displayed a sulfide-dependent increase in luminescence, while Tb complex 2 displayed a decrease in luminescence upon exposure to NaHS. The utility of the complexes for monitoring sulfide levels in industrial oil and water samples was investigated. Complex 3 provided a sensitive measure of sulfide levels in petrochemical water samples (detection limit ∼ 250 nM), while complex 1 was capable of monitoring μM levels of sulfide in partially refined crude oil. - Highlights: • Lanthanide–azide based sulfide sensors were synthesized and characterized. • The probes have excitation and emission profiles compatible with sulfide-contaminated samples from the petrochemical industry. • A terbium-based probe was used to measure the sulfide concentration in oil refinery wastewater. • A europium-based probe had compatibility with partially refined crude oil samples.

  15. Lanthanide complexes as luminogenic probes to measure sulfide levels in industrial samples

    Energy Technology Data Exchange (ETDEWEB)

    Thorson, Megan K. [Department of Medicinal Chemistry, University of Utah College of Pharmacy, Salt Lake City, UT 84108 (United States); Ung, Phuc [Monash Institute of Pharmaceutical Sciences, Monash University, Victoria 3052 (Australia); Leaver, Franklin M. [Water & Energy Systems Technology, Inc., Kaysville, UT 84037 (United States); Corbin, Teresa S. [Quality Services Laboratory, Tesoro Refining and Marketing, Salt Lake City, UT 84103 (United States); Tuck, Kellie L., E-mail: kellie.tuck@monash.edu [School of Chemistry, Monash University, Victoria 3800 (Australia); Graham, Bim, E-mail: bim.graham@monash.edu [Monash Institute of Pharmaceutical Sciences, Monash University, Victoria 3052 (Australia); Barrios, Amy M., E-mail: amy.barrios@utah.edu [Department of Medicinal Chemistry, University of Utah College of Pharmacy, Salt Lake City, UT 84108 (United States)

    2015-10-08

    A series of lanthanide-based, azide-appended complexes were investigated as hydrogen sulfide-sensitive probes. Europium complex 1 and Tb complex 3 both displayed a sulfide-dependent increase in luminescence, while Tb complex 2 displayed a decrease in luminescence upon exposure to NaHS. The utility of the complexes for monitoring sulfide levels in industrial oil and water samples was investigated. Complex 3 provided a sensitive measure of sulfide levels in petrochemical water samples (detection limit ∼ 250 nM), while complex 1 was capable of monitoring μM levels of sulfide in partially refined crude oil. - Highlights: • Lanthanide–azide based sulfide sensors were synthesized and characterized. • The probes have excitation and emission profiles compatible with sulfide-contaminated samples from the petrochemical industry. • A terbium-based probe was used to measure the sulfide concentration in oil refinery wastewater. • A europium-based probe had compatibility with partially refined crude oil samples.

  16. Low-level measurements by liquid scintillation counting

    International Nuclear Information System (INIS)

    Schoenhofer, F.

    1991-01-01

    Liquid scintillation counting has become a convenient tool for analysis of many beta- and alpha-emitters even in ultra low-level concentration ranges. Extremely low background is achieved in a commercially available counter by an active shielding and heavy lead shielding. Thus special time saving radiochemical separation processes could be designed. Extremely simple sample preparation techniques can be used. Counting time can be reduced and sample throughput enhanced. Also precision can be enhanced. From the author's research, several applications are discussed. They include: tritium in water without enrichment, tritium in urine (excretion analysis), carbon-14 in samples like alcohol or vinegar, Rn-222 in water and air, even gaseous Kr-85. A simple and fast method for Sr-90 in environmental samples and food has been developed and the Ra-226-concentration in water can be measured as low as 30 mBq/l without any chemical separation or enrichment. The instrument has been used successfully for screening purposes after the Chernobyl accident as well as for monitoring groundwater after a large scale contamination in Lower Austria. Using a 'gross-beta-measurement' effluents from a nuclear installation are monitored, clearly showing advantages over traditional methods. α-β-discrimination reduces the background for alpha emitters to practically zero. Examples from the determination of Ra-226 in water are shown

  17. Low-Level Plutonium Bioassay Measurements at the Lawrence Livermore National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, T; Brown, T; Hickman, D; Marchetti, A; Williams, R; Kehl, S

    2007-06-18

    Plutonium-239 ({sup 239}Pu) and plutonium-240 ({sup 240}Pu) are important alpha emitting radionuclides contained in radioactive debris from nuclear weapons testing. {sup 239}Pu and {sup 240}Pu are long-lived radionuclides with half-lives of 24,400 years and 6580 years, respectively. Concerns over human exposure to plutonium stem from knowledge about the persistence of plutonium isotopes in the environment and the high relative effectiveness of alpha-radiation to cause potential harm to cells once incorporated into the human body. In vitro bioassay tests have been developed to assess uptakes of plutonium based on measured urinary excretion patterns and modeled metabolic behaviors of the absorbed radionuclides. Systemic plutonium absorbed by the deep lung or from the gastrointestinal tract after ingestion is either excreted or distributed to other organs, primarily to the liver and skeleton, where it is retained for biological half-times of around 20 and 50 years, respectively. Dose assessment and atoll rehabilitation programs in the Marshall Islands have historically given special consideration to residual concentrations of plutonium in the environment even though the predicted dose from inhalation and/or ingestion of plutonium accounts for less than 5% of the annual effective dose from exposure to fallout contamination. Scientists from the Lawrence Livermore National Laboratory (LLNL) have developed a state-of-the-art bioassay test to assess urinary excretion rates of plutonium from Marshallese populations. This new heavy-isotope measurement system is based on Accelerator Mass Spectrometry (AMS). The AMS system at LLNL far exceeds the standard measurement requirements established under the latest United States Department of Energy (DOE) regulation, 10CFR 835, for occupational monitoring of plutonium, and offers several advantages over classical as well as competing new technologies for low-level detection and measurement of plutonium isotopes. The United States

  18. Optical Mass Gauging System for Measuring Liquid Levels in a Reduced Gravity Environment

    Science.gov (United States)

    Sullenberger, Ryan M.; Munoz, Wesley M.; Lyon, Matt P.; Vogel, Kenny; Yalin, Azer P.; Korman, Valentin; Polzin, Kurt A.

    2010-01-01

    A compact and rugged fiber-coupled liquid volume sensor designed for flight on a sounding rocket platform is presented. The sensor consists of a Mach-Zehnder interferometer capable of measuring the amount of liquid contained in a tank under any gravitational conditions, including a microgravity environment, by detecting small changes in the index of refraction of the gas contained within a sensing region. By monitoring changes in the interference fringe pattern as the system undergoes a small compression provided by a piston, the ullage volume of a tank can be directly measured allowing for a determination of the liquid volume. To demonstrate the technique, data are acquired using two tanks containing different volumes of liquid, which are representative of the levels of liquid in a tank at different time periods during a mission. The two tanks are independently exposed to the measurement apparatus, allowing for a determination of the liquid level in each. In a controlled, laboratory test of the unit, the system demonstrated a capability of measuring a liquid level in an individual tank of 10.53 mL with a 2% error. The overall random uncertainty for the flight system is higher than that one test, at +/- 1.5 mL.

  19. Measuring Your Fitness Level

    Science.gov (United States)

    ... online calculator. If you'd rather do the math yourself, divide your weight in pounds by your ... Human Services recommends one of the following activity levels for adult fitness and health benefits: 150 minutes ...

  20. Low-Cost Alternative for the Measurement of Water Levels in Surface Water Streams

    Directory of Open Access Journals (Sweden)

    Luis E. PEÑA

    2017-11-01

    Full Text Available Flood risk management and water resources planning involve a deep knowledge of surface streams so that mitigation strategies and climate change adaptations can be implemented. Commercially, there is a wide range of technologies for the measurement of hydroclimatic variables; however, many of these technologies may not be affordable for institutions with limited budgets. This paper has two main objectives: 1 Present the design of an ultrasound-based water level measurement system, and 2 Propose a methodological alternative for the development of instruments, according to the needs of institutions conducting monitoring of surface waterbodies. To that end, the proposed methodology is based on selection processes defined according to the specific needs of each waterbody. The prototype was tested in real-world scale, with the potential to obtain accurate measurements. Lastly, we present the design of the ultrasound-based water level measurement instrument, which can be built at a low cost. Low-cost instruments can potentially contribute to the sustainable instrumental autonomy of environmental entities and help define measurement and data transmission standards based on the specific requirements of the monitoring.

  1. Optimizing measurement sensitivity to facilitate monitoring environmental levels of Rn-daughter concentrations

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Groer, P.G.; Witek, R.T.

    1977-01-01

    In the measurement of environmental levels of radioactivity, the primary problem is the accumulation of a statistically meaningful number of counts within a reasonable period of time. In the case of measurements of airborne 222 Rn-daughter concentrations, the problem is further complicated by the particularly short half-life, 3.05 minutes, of RaA (Po 218 ). Since the Rn-daughters, (RaA, RaB [Pb 214 ] and RaC [Bi 214 ]) are of interest, the equations interrelating these Rn-daughter concentrations were derived from the laws of radioactive-series decay. These equations, although straightforward, are cumbersome to solve. To facilitate the efficient use of these equations, a computer program has been written which permits the calculation of Rn-daughter concentrations or expected counts for a given set of measurement parameters (flow rate and detector efficiencies). A subroutine then calculates the optimum pumping and counting times required to provide the number of counts necessary for acceptable statistics at environmental levels of 222 Rn-daughter concentrations. This subroutine contains a set of parameters, flow rate and efficiencies, that are fixed using realistic restrictions. The use of these optimized pumping and counting times results in maximum measurement sensitivity under realistic constraints

  2. EISCAT measurements of solar wind velocity and the associated level of interplanetary scintillation

    Directory of Open Access Journals (Sweden)

    R. A. Fallows

    2002-09-01

    Full Text Available A relative scintillation index can be derived from EISCAT observations of Interplanetary Scintillation (IPS usually used to study the solar wind velocity. This provides an ideal opportunity to compare reliable measurements of the solar wind velocity derived for a number of points along the line-of-sight with measurements of the overall level of scintillation. By selecting those occasions where either slow- or fast-stream scattering was dominant, it is shown that at distances from the Sun greater than 30 RS , in both cases the scintillation index fell with increasing distance as a simple power law, typically as R-1.7. The level of scintillation for slow-stream scattering is found to be 2.3 times the level for fast-stream scattering.Key words. Interplanetary physics (solar wind plasma

  3. Azimuth selection for sea level measurements using geodetic GPS receivers

    Science.gov (United States)

    Wang, Xiaolei; Zhang, Qin; Zhang, Shuangcheng

    2018-03-01

    Based on analysis of Global Positioning System (GPS) multipath signals recorded by a geodetic GPS receiver, GPS Reflectometry (GPS-R) has demonstrated unique advantages in relation to sea level monitoring. Founded on multipath reflectometry theory, sea level changes can be measured by GPS-R through spectral analysis of recorded signal-to-noise ratio data. However, prior to estimating multipath parameters, it is necessary to define azimuth and elevation angle mask to ensure the reflecting zones are on water. Here, a method is presented to address azimuth selection, a topic currently under active development in the field of GPS-R. Data from three test sites: the Kachemak Bay GPS site PBAY in Alaska (USA), Friday Harbor GPS site SC02 in the San Juan Islands (USA), and Brest Harbor GPS site BRST in Brest (France) are analyzed. These sites are located in different multipath environments, from a rural coastal area to a busy harbor, and they experience different tidal ranges. Estimates by the GPS tide gauges at azimuths selected by the presented method are compared with measurements from physical tide gauges and acceptable correspondence found for all three sites.

  4. Deployment of quasi-digital sensor for high temperature molten salt level measurement in pyroprocessing plants

    Science.gov (United States)

    Sanga, Ramesh; Agarwal, Sourabh; Sivaramakrishna, M.; Rao, G. Prabhakara

    2018-04-01

    Development of a liquid molten salt level sensor device that can detect the level of liquid molten salt in the process vessels of pyrochemical reprocessing of spent metallic fuels is detailed. It is proposed to apply a resistive-type pulsating sensor-based level measurement approach. There are no commercially available sensors due to limitations of high temperature, radiation, and physical dimensions. A compact, simple, rugged, low power, and high precise pulsating sensor-based level probe and simple instrumentation for the molten salt liquid level sensor to work in the extreme conditions has been indigenously developed, with high precision and accuracy. The working principle, design concept, and results have been discussed. This level probe is mainly composed of the variable resistor made up of ceramic rods. This resistor constitutes the part of resistance-capacitance-type Logic Gate Oscillator (LGO). A change in the molten salt level inside the tank causes a small change in the resistance which in turn changes the pulse frequency of the LGO. Thus the frequency, the output of the instrument that is displayed on the LCD of an embedded system, is a function of molten salt level. In the present design, the range of level measurement is about 10 mm. The sensitivity in position measurement up to 10 mm is ˜2.5 kHz/mm.

  5. Ultra Low Level Environmental Neutron Measurements Using Superheated Droplet Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, A.C. [Centro de Ciencias e Tecnologias Nucleares, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, Estrada Nacional 10 - km 139.7, 2695-066 Bobadela LRS (Portugal); Centro de Fisica Nuclear, Universidade de Lisboa. Av. Prof. Gama Pinto, 2, 1649- 003 Lisboa (Portugal); Felizardo, M.; Girard, T.A.; Kling, A.; Ramos, A.R. [Centro de Fisica Nuclear, Universidade de Lisboa. Av. Prof. Gama Pinto, 2, 1649- 003 Lisboa (Portugal); Marques, J.G.; Prudencio, M.I.; Marques, R.; Carvalho, F.P. [Centro de Ciencias e Tecnologias Nucleares, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, Estrada Nacional 10 - km 139.7, 2695-066 Bobadela LRS (Portugal)

    2015-07-01

    Through the application of superheated droplet detectors (SDDs), the SIMPLE project for the direct search for dark matter (DM) reached the most restrictive limits on the spin-dependent sector to date. The experiment is based on the detection of recoils following WIMP-nuclei interaction, mimicking those from neutron scattering. The thermodynamic operation conditions yield the SDDs intrinsically insensitive to radiations with linear energy transfer below ∼150 keVμm{sup -1} such as photons, electrons, muons and neutrons with energies below ∼40 keV. Underground facilities are increasingly employed for measurements in a low-level radiation background (DM search, gamma-spectroscopy, intrinsic soft-error rate measurements, etc.), where the rock overburden shields against cosmic radiation. In this environment the SDDs are sensitive only to α-particles and neutrons naturally emitted from the surrounding materials. Recently developed signal analysis techniques allow discrimination between neutron and α-induced signals. SDDs are therefore a promising instrument for low-level neutron and α measurements, namely environmental neutron measurements and α-contamination assays. In this work neutron measurements performed in the challenging conditions of the latest SIMPLE experiment (1500 mwe depth with 50-75 cm water shield) are reported. The results are compared with those obtained by detailed Monte Carlo simulations of the neutron background induced by {sup 238}U and {sup 232}Th traces in the facility, shielding and detector materials. Calculations of the neutron energy distribution yield the following neutron fluence rates (in 10{sup -8} cm{sup -2}s{sup -1}): thermal (<0.5 eV): 2.5; epithermal (0.5 eV-100 keV): 2.2; fast (>1 MeV): 3.9. Signal rates were derived using standard cross sections and codes routinely employed in reactor dosimetry. The measured and calculated neutron count rates per unit of active mass were 0.15 ct/kgd and 0.33 ct/kg-d respectively. As the major

  6. Measurement of the natural radiation background level of Riyadh City

    International Nuclear Information System (INIS)

    Al-Kusayer, T.A.; Al-Haj, A.N.

    1987-01-01

    A gamma spectroscopy system was used to analyze the radionuclides in soil samples and to determine the cumulative radioactivity of terrestrial origin in the Riyadh City area. Minimal work has been done in the 1980s to measure the natural background radiation level in Saudi Arabia by using thermoluminescent dosimeters. The measurement of the natural radioactivity in the Riyadh area for the radionuclide concentration in becquerels per kilogram, the exposure rate arising from radionuclides in grays per hour, and the equivalent dose rate in sieverts per hour are the goals of this work. Soil samples were collected from 21 places in Riyadh City. Each site was sampled for two depth profiles, 0 to 5 cm and 5 to 15 cm. These measurements were taken before the Chernobyl accident, and in the absence of any measurements for that area in the past, this work can be considered in future work for a reference 137 Cs concentration in Riyadh soil to determine the 137 Cs increase in the soil after the Chernobyl accident

  7. Consideration of tidal influences in determining measurement periods when monitoring built-environment radon levels

    International Nuclear Information System (INIS)

    Crockett, R.G.M.; Phillips, P.S.; Gillmore, G.K.; Denman, A.R.; Groves-Kirkby, C.J.

    2006-01-01

    Using three hourly-sampling continuous radon monitors, deployed at separate locations in and around the town of Northampton, UK, during the period May 2002 to September 2005, evidence has been identified of tidal influences on built environment radon levels. The data-sets from these deployments, together with additional data-sets collected from a house in Devon, UK, over the period May 1994 to October 1996, and made available by the UK Building Research Establishment, have been analysed using a number of analytical techniques, including a novel correlation technique developed during the investigation. Radon concentration levels in all of the investigated sites exhibit cyclic variation with a period of approximately 14-15 days, equivalent to the spring-tide interval, and lag the corresponding new and full moons by varying periods. The tide/radon lag interval for the two public-sector buildings changes abruptly in September/October, indicating that a significant characteristic of these buildings changes at this time. For domestic properties, the lag is relatively unchanged during the year, but is greater in Devon, in the South-West of England, than in Northampton, in the English East Midlands. These differences are attributed to location relative to coastlines (the South-West experiences greater tidal-loading than the Midlands), underlying geology and rock/soil hydration. Depending on its position within the local 14 to 15-day tidally-induced radon cycle, an individual 7-day radon measurement may yield an erroneous estimate of longer term average levels, up to 46% higher or lower than the average level for one of the reported data-sets. Thus a building with a mean radon concentration below the local Action Level could appear to be unsafe if measured around a tidal-cyclic radon maximum: conversely, a building with a mean radon concentration above the Action Level could appear to be safe when measured around a tidal-cyclic radon minimum. A minimum radon-measurement

  8. Do Activity Level Outcome Measures Commonly Used in Neurological Practice Assess Upper-Limb Movement Quality?

    Science.gov (United States)

    Demers, Marika; Levin, Mindy F

    2017-07-01

    Movement is described in terms of task-related end point characteristics in external space and movement quality (joint rotations in body space). Assessment of upper-limb (UL) movement quality can assist therapists in designing effective treatment approaches for retraining lost motor elements and provide more detailed measurements of UL motor improvements over time. To determine the extent to which current activity level outcome measures used in neurological practice assess UL movement quality. Outcome measures assessing arm/hand function at the International Classification of Function activity level recommended by neurological clinical practice guidelines were reviewed. Measures assessing the UL as part of a general mobility assessment, those strictly evaluating body function/structure or participation, and paediatric measures were excluded. In all, 15 activity level outcome measures were identified; 9 measures assess how movement is performed by measuring either end point characteristics or movement quality. However, except for the Reaching Performance Scale for Stroke and the Motor Evaluation Scale for Upper Extremity in Stroke Patients, these measures only account for deficits indirectly by giving a partial score if movements are slower or if the person experiences difficulties. Six outcome measures neither assess any parameters related to movement quality, nor distinguish between improvements resulting from motor compensation or recovery of desired movement strategies. Current activity measures may not distinguish recovery from compensation and adequately track changes in movement quality over time. Movement quality may be incorporated into clinical assessment using observational kinematics with or without low-cost motion tracking technology.

  9. MEASURING INSTRUMENT CONSTRUCTION AND VALIDATION IN ESTIMATING UNICYCLING SKILL LEVEL

    Directory of Open Access Journals (Sweden)

    Ivan Granić

    2012-09-01

    Full Text Available Riding the unicycle presupposes the knowledge of the set of elements which describe motoric skill, or just part of that set with which we could measure the level of that knowledge. Testing and evaluation of the elements is time consuming. In order to design a unique, composite measuring instrument, to facilitate the evaluation of the initial level of unicycling skill, we tested 17 recreative subjects who were learning to ride the unicycle in 15 hours of training, without any previous knowledge or experience what was measured before the beginning of the training. At the beginning and at the end of the training they were tested with the set of the 12 riding elements test that was carried out to record only successful attempts, followed by unique SLALOM test which include previously tested elements. It was found that the unique SLALOM test has good metric features and a high regression coefficient showed that the SLALOM could be used instead of the 12 elements of unicycle riding skill, and it could be used as a uniform test to evaluate learned or existing knowledge. Because of its simplicity in terms of action and simultaneous testing of more subjects, the newly constructed test could be used in evaluating the unicycling recreational level, but also for monitoring and programming transformation processes to develop the motor skills of riding of unicycle. Because of its advantages, it is desirable to include unicycling in the educational processes of learning new motor skills, which can be evaluated by the results of this research. The obtained results indicate that the unicycle should be seriously consider as a training equipment to “refresh” or expand the recreational programs, without any fear that it is just for special people. Namely, it was shown that the previously learned motor skills (skiing, roller-skating, and cycling had no effect on the results of final testing.

  10. Readability Level of Spanish-Language Patient-Reported Outcome Measures in Audiology and Otolaryngology

    Science.gov (United States)

    Coco, Laura; Colina, Sonia; Atcherson, Samuel R.

    2017-01-01

    Purpose The purpose of this study was to examine the readability level of the Spanish versions of several audiology- and otolaryngology-related patient-reported outcome measures (PROMs) and include a readability analysis of 2 translation approaches when available—the published version and a “functionalist” version—using a team-based collaborative approach including community members. Method Readability levels were calculated using the Fry Graph adapted for Spanish, as well as the Fernandez-Huerta and the Spaulding formulae for several commonly used audiology- and otolaryngology-related PROMs. Results Readability calculations agreed with previous studies analyzing audiology-related PROMs in English and demonstrated many Spanish-language PROMs were beyond the 5th grade reading level suggested for health-related materials written for the average population. In addition, the functionalist versions of the PROMs yielded lower grade-level (improved) readability levels than the published versions. Conclusion Our results suggest many of the Spanish-language PROMs evaluated here are beyond the recommended readability levels and may be influenced by the approach to translation. Moreover, improved readability may be possible using a functionalist approach to translation. Future analysis of the suitability of outcome measures and the quality of their translations should move beyond readability and include an evaluation of the individual's comprehension of the written text. PMID:28892821

  11. Quality assurance of external exposure measurement for national survey of environmental natural radioactive level

    International Nuclear Information System (INIS)

    Yue Qingyu

    1995-01-01

    This paper summarizes the quality assurance work of external exposure measurement for national survey of environmental natural radioactive level. It mainly introduces instrumentation used in external exposure measurement and its properties, the measurement results of three times of national in-site intercomparison, and in-site sample check results of measurement results from 29 provinces, cities and autonomous regions and Wuhan, Baotou cities

  12. Parameters affecting level measurement interpretation of nuclear fuel solutions

    International Nuclear Information System (INIS)

    Hunt, B.A.; Landat, D.A.

    1999-01-01

    This paper describes a level measurement technique commonly used in the measurement of radioactive liquids and equipment utilised by the inspectors for safeguards purposes. Some of the influencing parameters affecting the measurement results by this technique are characterised. An essential requisite for successful process operations in chemical facilities involving liquids generally require some physical measurements to be made in-line for both process and quality control in order to achieve the necessary final product specifications . In nuclear fuel reprocessing facilities, the same objectives apply coupled however with an additional requirement of achieving nuclear material accountancy and control. In view of the strategic importance of some of the process vessels in nuclear facilities, accountancy has to be supported by volume and density measurements of low uncertainty. Inspectors therefore require instruments which are at the very least as good as or better than operator's equipment. The classical measurement technique and most widely applied for process liquids in nuclear installations is the bubbler probe or dip-tube technique. Here a regulated flow of air passes through tubes inserted to various depths into the vessel and pressure readings are measured which are a function of the presence of liquid height and density of solution in the tank. These readings, taken together with a pre-determined calibration curve are sufficient for the volume and amount of liquor in a tank to be quantified. All measurement equipment and instrumentation are long distances from the tank environment. The key physical parameter to measure at this location is therefore pressure. Equipment designed developed, commissioned and tested in the tank measurement facilities at Ispra and in nuclear installations in Europe, Japan and the USA, house digital pressure transducer modules with manufacture's declared features of better than 0.01% accuracy and long term stability of 0.01% full

  13. Proficiency testing criteria for clearance level in solid waste gamma measurement in Taiwan

    International Nuclear Information System (INIS)

    Chen, Chun-Liang; Wang, Jeng-Jong; Chiu, Huang-Sheng

    2013-01-01

    To guarantee the measurement quality for clearance level in solid waste material, the Institute of Nuclear Energy Research (INER) established the criteria for proficiency testing of clearance level measurement. INER and the Taiwan Accreditation Foundation (TAF) organized the Technique Committee Meeting twice to discuss these criteria in 2011. The participating laboratories must completely conform to the ISO/IEC 17025, and they also must meet the requirements of the criteria. According to the criteria, the participating laboratories analyzed the minimum detectable amount (MDA) and that should be less than 20% of the clearance level (AMDA) given in the Atomic Energy Council's (AEC) “Regulations on Clearance Level for Radioactive Waste Management”. The testing results should conform to the deviation and traceability requirements. - Highlights: • The participating laboratories must completely conform to the ISO/IEC 17025 • The proficiency testing items were basically in two categories, box and barrel types • Analyzed the MDA and that should be less than 20% of the release level given in the AEC. • The are three limitations: MDA< AMDA, -0.25< Bi<+0.5, and En≤1.0 and uncertainty<20%

  14. Heated junction thermocouple level measurement apparatus

    International Nuclear Information System (INIS)

    Bevilacqua, F.; Burger, J.M.

    1984-01-01

    A liquid level sensing apparatus senses the level of liquid surrounding the apparatus. A plurality of axially spaced sensors are enclosed in a separator tube. The separator tube tends to collapse the level of a two-phase fluid within the separator tube into essentially a liquid phase and a gaseous phase where the collapsed level bears a relationship to the coolant inventory outside the separator tube. The level of the liquid phase is sensed by level sensing apparatus. The separator tube contains inlet-outlet ports near the top and bottom thereof to equalize the liquid level inside and outside the separator tube when the level fluctuates or the water within the separator tube flashes to steam. Each sensor is comprised of a heater, a heated thermocouple junction and an unheated thermocouple junction within an elongated heat conductive housing. The heated portion of housing is enclosed in a splash guard with inlet-outlet ports near the top and bottom to equalize the liquid level inside and outside the splash guardand to eliminate the spurious indications of liquid level change which may arise if water droplets contact the housing in the region of the heater. To prevent steam bubbles entrained in a two-phase fluid cross flow from entering the lateral inlet-outlet ports of the separator tube, the separator tube is enclosed in support tube which may in turn be enclosed in an otherwise unused control element assembly shroud. The lateral inlet-outlet ports of separator tube are axially offset from lateral inlet-outlet ports of support tube at least where support tube is subjected to cross flow. The shroud is open on the bottom and has lateral inlet-outlet ports to facilitate liquid level fluctuations to equalize inside and outside shroud

  15. Measurement of speech levels in the presence of time varying background noise

    Science.gov (United States)

    Pearsons, K. S.; Horonjeff, R.

    1982-01-01

    Short-term speech level measurements which could be used to note changes in vocal effort in a time varying noise environment were studied. Knowing the changes in speech level would in turn allow prediction of intelligibility in the presence of aircraft flyover noise. Tests indicated that it is possible to use two second samples of speech to estimate long term root mean square speech levels. Other tests were also performed in which people read out loud during aircraft flyover noise. Results of these tests indicate that people do indeed raise their voice during flyovers at a rate of about 3-1/2 dB for each 10 dB increase in background level. This finding is in agreement with other tests of speech levels in the presence of steady state background noise.

  16. Local, atomic-level elastic strain measurements of metallic glass thin films by electron diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Ebner, C. [Physics of Nanostructured Materials, Faculty of Physics, University of Vienna, Boltzmanngasse 5, 1090 Vienna (Austria); Sarkar, R. [Department of Materials Science and Engineering, School for Engineering of Matter Transport and Energy, Arizona State University, Tempe 85287 (United States); Rajagopalan, J. [Department of Materials Science and Engineering, School for Engineering of Matter Transport and Energy, Arizona State University, Tempe 85287 (United States); Department of Mechanical and Aerospace Engineering, School for Engineering of Matter Transport and Energy, Arizona State University, Tempe 85287 (United States); Rentenberger, C., E-mail: christian.rentenberger@univie.ac.at [Physics of Nanostructured Materials, Faculty of Physics, University of Vienna, Boltzmanngasse 5, 1090 Vienna (Austria)

    2016-06-15

    A novel technique is used to measure the atomic-level elastic strain tensor of amorphous materials by tracking geometric changes of the first diffuse ring of selected area electron diffraction patterns (SAD). An automatic procedure, which includes locating the centre and fitting an ellipse to the diffuse ring with sub-pixel precision is developed for extracting the 2-dimensional strain tensor from the SAD patterns. Using this technique, atomic-level principal strains from micrometre-sized regions of freestanding amorphous Ti{sub 0.45}Al{sub 0.55} thin films were measured during in-situ TEM tensile deformation. The thin films were deformed using MEMS based testing stages that allow simultaneous measurement of the macroscopic stress and strain. The calculated atomic-level principal strains show a linear dependence on the applied stress, and good correspondence with the measured macroscopic strains. The calculated Poisson’s ratio of 0.23 is reasonable for brittle metallic glasses. The technique yields a strain accuracy of about 1×10{sup −4} and shows the potential to obtain localized strain profiles/maps of amorphous thin film samples. - Highlights: • A TEM method to measure elastic strain in metallic glass films is proposed. • Method is based on tracking geometric changes in TEM diffraction patterns. • An automatic procedure is developed for extracting the local strain tensor. • Atomic-level strain in amorphous TiAl film was analysed during in-situ deformation. • Capability of the method to obtain micrometer scale strain profiles/maps is shown.

  17. Exposure to pyrethroids insecticides and serum levels of thyroid-related measures in pregnant women

    International Nuclear Information System (INIS)

    Zhang, Jie; Hisada, Aya; Yoshinaga, Jun; Shiraishi, Hiroaki; Shimodaira, Kazuhisa; Okai, Takashi; Noda, Yumiko; Shirakawa, Miyako; Kato, Nobumasa

    2013-01-01

    Possible association between environmental exposure to pyrethroid insecticides and serum thyroid-related measures was explored in 231 pregnant women of 10–12 gestational weeks recruited at a university hospital in Tokyo during 2009–2011. Serum levels of free thyroxine (fT4), thyroid stimulating hormone (TSH) and thyroid biding globulin (TBG) and urinary pyrethroid insecticide metabolite (3-phenoxybenzoic acid, 3-PBA) were measured. Obstetrical information was obtained from medical records and dietary and lifestyle information was collected by self-administered questionnaire. Geometric mean concentration of creatinine-adjusted urinary 3-PBA was 0.363 (geometric standard deviation: 3.06) μg/g cre, which was consistent with the previously reported levels for non-exposed Japanese adult females. The range of serum fT4, TSH and TBG level was 0.83–3.41 ng/dL, 0.01–27.4 μIU/mL and 16.4–54.4 μg/mL, respectively. Multiple regression analysis was carried out by using either one of serum levels of thyroid-related measures as a dependent variable and urinary 3-PBA as well as other potential covariates (age, pre-pregnancy BMI, parity, urinary iodine, smoking and drinking status) as independent variables: 3-PBA was not found as a significant predictor of serum level of thyroid-related measures. Lack of association may be due to lower pyrethroid insecticide exposure level of the present subjects. Taking the ability of pyrethroid insecticides and their metabolite to bind to nuclear thyroid hormone (TH) receptor, as well as their ability of placental transfer, into consideration, it is warranted to investigate if pyrethroid pesticides do not have any effect on TH actions in fetus brain even though maternal circulating TH level is not affected. -- Highlights: • Pyrethroid exposure and thyroid hormone status was examined in pregnant women. • Urinary 3-phenoxybenzoic acid was used as a biomarker of exposure. • Iodine nutrition, age and other covariates were included

  18. Exposure to pyrethroids insecticides and serum levels of thyroid-related measures in pregnant women

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jie; Hisada, Aya [Department of Environmental Studies, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8563 (Japan); Yoshinaga, Jun, E-mail: junyosh@k.u-tokyo.ac.jp [Department of Environmental Studies, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8563 (Japan); Shiraishi, Hiroaki [National Institute for Environmental Studies, Onogawa 16-2, Tsukuba, Ibaraki 305-8563 (Japan); Shimodaira, Kazuhisa; Okai, Takashi [Department of Obstetrics and Gynecology, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa, Tokyo 142-8555 (Japan); Noda, Yumiko; Shirakawa, Miyako; Kato, Nobumasa [Department of Psychiatry and Neurology, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa, Tokyo 142-8555 (Japan)

    2013-11-15

    Possible association between environmental exposure to pyrethroid insecticides and serum thyroid-related measures was explored in 231 pregnant women of 10–12 gestational weeks recruited at a university hospital in Tokyo during 2009–2011. Serum levels of free thyroxine (fT4), thyroid stimulating hormone (TSH) and thyroid biding globulin (TBG) and urinary pyrethroid insecticide metabolite (3-phenoxybenzoic acid, 3-PBA) were measured. Obstetrical information was obtained from medical records and dietary and lifestyle information was collected by self-administered questionnaire. Geometric mean concentration of creatinine-adjusted urinary 3-PBA was 0.363 (geometric standard deviation: 3.06) μg/g cre, which was consistent with the previously reported levels for non-exposed Japanese adult females. The range of serum fT4, TSH and TBG level was 0.83–3.41 ng/dL, 0.01–27.4 μIU/mL and 16.4–54.4 μg/mL, respectively. Multiple regression analysis was carried out by using either one of serum levels of thyroid-related measures as a dependent variable and urinary 3-PBA as well as other potential covariates (age, pre-pregnancy BMI, parity, urinary iodine, smoking and drinking status) as independent variables: 3-PBA was not found as a significant predictor of serum level of thyroid-related measures. Lack of association may be due to lower pyrethroid insecticide exposure level of the present subjects. Taking the ability of pyrethroid insecticides and their metabolite to bind to nuclear thyroid hormone (TH) receptor, as well as their ability of placental transfer, into consideration, it is warranted to investigate if pyrethroid pesticides do not have any effect on TH actions in fetus brain even though maternal circulating TH level is not affected. -- Highlights: • Pyrethroid exposure and thyroid hormone status was examined in pregnant women. • Urinary 3-phenoxybenzoic acid was used as a biomarker of exposure. • Iodine nutrition, age and other covariates were included

  19. A measurement control program to meet desired levels of precision and accuracy

    International Nuclear Information System (INIS)

    Bruckner, L.A.

    1991-01-01

    Measurement control programs are usually designed to test for precision and accuracy. Many instruments, however, display non-random data patterns such as biases or seasonal variations which are statistically significant but are of no practical significance. Application of the usual statistical tests can cause these instruments to be removed from service unnecessarily. It is tempting to try to overcome this problem by frequently adjusting the instrument or by arbitrarily changing the parameters of the statistical tests so that failures occur less often. This, of course invalidates the statistical tests. In the author's opinion, the correct way to handle this problem is to identify the desired levels of precision and accuracy, and then to combine these levels with valid statistical techniques in the measurement control-program. This paper describes one way to accomplish this

  20. Radiative-lifetime measurements and calculations of odd-parity highly excited levels in Ba i

    International Nuclear Information System (INIS)

    Zhang Wei; Du Shan; Palmeri, Patrick; Quinet, Pascal; Biemont, Emile; Dai Zhenwen

    2010-01-01

    Natural radiative lifetime measurements have been performed for 70 odd-parity highly excited levels of neutral barium in the energy range from 308 15.512 to 417 59.93 cm -1 by a time-resolved laser-induced fluorescence technique in a laser-produced plasma. The lifetime values measured in this paper are in the range from 11.3 to 901 ns. They are compared with the published lifetimes of four levels. Two of them are in good agreement, whereas for the other two our measurements are slightly longer than the published data. The reasons for the discrepancies are discussed. Comparisons with theoretical results of the Hartree-Fock method with relativistic corrections illustrate the difficulties associated with the use of Cowan's codes for obtaining accurate branching fractions for transitions depopulating highly excited levels along the Rydberg series of heavy neutral elements. This work will be useful to extend the set of oscillator strengths available in Ba i.

  1. Measuring the Level of Socialization in Children with Autism Spectrum Disorder

    Directory of Open Access Journals (Sweden)

    Khaustov A.V.,

    2016-10-01

    Full Text Available Difficulties with socialization common for children with autism spectrum disorder (ASD are a serious problem for their inclusion into educational settings. These socialization deficits are basically related to underdeveloped social skills. The paper describes a study aimed at revealing the level of socialization in children with ASD. The study involved 117 children aged 5–7 years and their parents. The children’s socialization level was measured with the Vineland Adaptive Behavior Scale. The outcomes showed that most children with ASD display low levels of socialization resulting in their inability to adequately communicate and cooperate with other people as in play, as in everyday life. Two factors were found to affect the level of socialization in the children: deficit of motivation and specific cognitive impairments. The paper argues for the necessity of developing a program for psychologi- cal and educational assistance aimed at forming social skills in children with ASD.

  2. Mutations at the Level of the Measures Adopted by Monetary Authorities

    Directory of Open Access Journals (Sweden)

    Marius Constantin APOSTOAIE

    2011-11-01

    Full Text Available Following the intensification of the international financial crisis in autumn 2008 the functioning of the financial system was seriously hindered. Central banks around the world responded firmly by lowering their key interest rates to historically low levels. As financial conditions didn’t improve as hoped and the real economy was still unstable, revealing therefore the limits of mainstream monetary policy, many monetary authorities employed several unconventional measures. This study documents two important approaches of classifying “unorthodox” monetary policies and reviews several measures undertook by central banks highlighting the impact and some of the possible risks to the contemporary economy.

  3. Reliability of Using Motion Sensors to Measure Children’s Physical Activity Levels in Exergaming

    Directory of Open Access Journals (Sweden)

    Nan Zeng

    2018-05-01

    Full Text Available Objectives: This study examined the reliability of two objective measurement tools in assessing children’s physical activity (PA levels in an exergaming setting. Methods: A total of 377 children (190 girls, Mage = 8.39, SD = 1.55 attended the 30-min exergaming class every other day for 18 weeks. Children’s PA levels were concurrently measured by NL-1000 pedometer and ActiGraph GT3X accelerometer, while children’s steps per min and time engaged in sedentary, light, and moderate-to-vigorous PA were estimated, respectively. Results: The results of intraclass correlation coefficient (ICC indicated a low degree of reliability (single measures ICC = 0.03 in accelerometers. ANOVA did detect a possible learning effect for 27 classes (p < 0.01, and the single measures ICC was 0.20 for pedometers. Moreover, there was no significant positive relationship between steps per min and time spent in moderate-to-vigorous physical activity (MVPA. Finally, only 1.3% variance was explained by pedometer as a predictor using Hierarchical Linear Modeling to further explore the relationship between pedometer and accelerometer data. Conclusions: The NL-1000 pedometers and ActiGraph GT3X accelerometers have low reliability in assessing elementary school children’s PA levels during exergaming. More research is warranted in determining the reliable and accurate measurement information regarding the use of modern devices in exergaming setting.

  4. Range and number-of-levels effects in derived and stated measures of attribute importance

    NARCIS (Netherlands)

    Verlegh, PWJ; Schifferstein, HNJ; Wittink, DR

    We study how the range of variation and the number of ttribute levels affect five measures of attribute importance: full profile conjoint estimates, ranges in attribute level attractiveness ratings. regression coefficients. graded paired comparisons. and self-reported ratings, We find that all

  5. DUQuE quality management measures: associations between quality management at hospital and pathway levels

    NARCIS (Netherlands)

    Wagner, C.; Groene, O.; Thompson, C.A.; DerSarkissian, M.; Klazinga, N.S.; Arah, O.A.; Sunol, R.

    2014-01-01

    Objective. The assessment of integral quality management (QM) in a hospital requires measurement and monitoring from different perspectives and at various levels of care delivery. Within the DUQuE project (Deepening our Understanding of Quality improvement in Europe), seven measures for QM were

  6. DUQuE quality management measures: associations between quality management at hospital and pathway levels.

    NARCIS (Netherlands)

    Wagner, C.; Groene, O.; Thompson, C.A.; DerSarkissian, M.; Klazinga, N.S.; Arah, O.A.; Suñol, R.

    2014-01-01

    Objective: The assessment of integral quality management (QM) in a hospital requires measurement and monitoring from different perspectives and at various levels of care delivery. Within the DUQuE project (Deepening our Understanding of Quality improvement in Europe), seven measures for QM were

  7. Resilience of Infrastructure Systems to Sea-Level Rise in Coastal Areas: Impacts, Adaptation Measures, and Implementation Challenges

    Directory of Open Access Journals (Sweden)

    Beatriz Azevedo de Almeida

    2016-11-01

    Full Text Available Expansive areas of low elevation in many densely populated coastal areas are at elevated risk of storm surges and flooding due to torrential precipitation, as a result of sea level rise. These phenomena could have catastrophic impacts on coastal communities and result in the destruction of critical infrastructure, disruption of economic activities and salt water contamination of the water supply. The objective of the study presented in this paper was to identify various impacts of sea level rise on civil infrastructures in coastal areas and examine the adaptation measures suggested in the existing literature. To this end, a systemic review of the existing literature was conducted in order to identify a repository of studies addressing sea level rise impacts and adaptation measures in the context of infrastructure systems. The study focused on three infrastructure sectors: water and wastewater, energy, and road transportation. The collected information was then analyzed in order to identify different categories of sea level rise impacts and corresponding adaptation measures. The findings of the study are threefold: (1 the major categories of sea level rise impacts on different infrastructure systems; (2 measures for protection, accommodation, and retreat in response to sea level rise impacts; and (3 challenges related to implementing adaptation measures.

  8. Ultrasonic instrument for continuous measurement of liquid levels in sodium systems

    International Nuclear Information System (INIS)

    Boehmer, L.S.

    1975-01-01

    An ultrasonic level measurement system which provides a continuous digital readout over a range of 3-180 inches, was tested in 500 0 F liquid sodium. The system proved to be accurate and reliable, required no initial warm-up period and experienced no long term drift. Modifications can extend the present operating temperatures to greater than 1200 0 F

  9. High level language for measurement complex control based on the computer E-100I

    Science.gov (United States)

    Zubkov, B. V.

    1980-01-01

    A high level language was designed to control the process of conducting an experiment using the computer "Elektrinika-1001". Program examples are given to control the measuring and actuating devices. The procedure of including these programs in the suggested high level language is described.

  10. Body measurements and testosteron level of male Timor deer (Rusa timorensis at various hierarchies

    Directory of Open Access Journals (Sweden)

    D. Samsudewa

    2017-12-01

    Full Text Available The aim of this research was to observe body (neck, chest and scrotum circumferences and testosterone level of α-male, β-male and subordinate male Timor deer reared under captivity after establisment of the dominance hierarchy. Twelve males (51 ± 6 months old; 68.29 ± 8.41 kg body weight and in same antler stages were used in this research. The bucks was grouped into three stall each containing four bucks. ELISA kit and tape measurements were used for plasma Testosterone assay and body measurement, respectively. Data was collected before and 43 days after establishment of the dominance hierarchy. Wilcoxon signed ranks test and Kruskal-Wallis H test of non-parametric analysis was used. Significant difference was tested with Mann-Whitney U test. The results showed no significantly different for body circumferences (neck, chest, scrotum and testosterone level of male Timor deer before establishment of dominance hierarchy. Chest and scrotum circumferences of male Timor deer after establihment of dominance hierarchy showed no significantly different. Significantly difference shown on parameter neck circumference (P<0.05; χ2 = 8.74 and testosteron level (P<0.05; χ2 = 7.87 after establishment of dominance hierarchy. In conclusion, dominance hierarchy affected the testosterone level and body measurement.

  11. Precision and accuracy of manual water-level measurements taken in the Yucca Mountain area, Nye County, Nevada, 1988--1990

    International Nuclear Information System (INIS)

    Boucher, M.S.

    1994-01-01

    Water-level measurements have been made in deep boreholes in the Yucca Mountain area, Nye County, Nevada, since 1983 in support of the US Department of Energy's Yucca Mountain Project, which is an evaluation of the area to determine its suit-ability as a potential storage area for high-level nuclear waste. Water-level measurements were taken either manually, using various water-level measuring equipment such as steel tapes, or they were taken continuously, using automated data recorders and pressure transducers. This report presents precision range and accuracy data established for manual water-level measurements taken in the Yucca Mountain area, 1988--90

  12. DUQuE quality management measures: associations between quality management at hospital and pathway levels

    NARCIS (Netherlands)

    Wagner, Cordula; Groene, Oliver; Thompson, Caroline A.; Dersarkissian, Maral; Klazinga, Niek S.; Arah, Onyebuchi A.; Suñol, Rosa; Kringos, D. S.; Lombarts, K.; Plochg, T.; Lopez, M. A.; Secanell, M.; Sunol, R.; Vallejo, P.; Bartels, P.; Kristensen, S.; Michel, P.; Saillour-Glenisson, F.; Vlcek, F.; Car, M.; Jones, S.; Klaus, E.; Garel, P.; Hanslik, K.; Saluvan, M.; Bruneau, C.; Depaigne-Loth, A.; Shaw, C.; Hammer, A.; Ommen, O.; Pfaff, H.; Groene, O.; Botje, D.; Wagner, C.; Kutaj-Wasikowska, H.; Kutryba, B.; Escoval, A.; Franca, M.; Almeman, F.; Kus, H.; Ozturk, K.; Mannion, R.; Chow, A.; Dersarkissian, M.; Thompson, C.; Wang, A.; Thompson, A.

    2014-01-01

    The assessment of integral quality management (QM) in a hospital requires measurement and monitoring from different perspectives and at various levels of care delivery. Within the DUQuE project (Deepening our Understanding of Quality improvement in Europe), seven measures for QM were developed. This

  13. The feasibility of well-logging measurements of arsenic levels using neutron-activation analysis

    Science.gov (United States)

    Oden, C.P.; Schweitzer, J.S.; McDowell, G.M.

    2006-01-01

    Arsenic is an extremely toxic metal, which poses a significant problem in many mining environments. Arsenic contamination is also a major problem in ground and surface waters. A feasibility study was conducted to determine if neutron-activation analysis is a practical method of measuring in situ arsenic levels. The response of hypothetical well-logging tools to arsenic was simulated using a readily available Monte Carlo simulation code (MCNP). Simulations were made for probes with both hyperpure germanium (HPGe) and bismuth germanate (BGO) detectors using accelerator and isotopic neutron sources. Both sources produce similar results; however, the BGO detector is much more susceptible to spectral interference than the HPGe detector. Spectral interference from copper can preclude low-level arsenic measurements when using the BGO detector. Results show that a borehole probe could be built that would measure arsenic concentrations of 100 ppm by weight to an uncertainty of 50 ppm in about 15 min. ?? 2006 Elsevier Ltd. All rights reserved.

  14. Using the TOEFL to measure the reading proficiency levels of deaf college applicants.

    Science.gov (United States)

    LoMaglio, L J

    1991-07-01

    The TOEFL is widely used by colleges and universities in the United States and Canada to measure the English language proficiency levels of hearing international applicants. At the National Technical Institute for the Deaf, a faculty committee recommended that this popular test instrument be used to measure the English reading skills of deaf international applicants to the National Technical Institute for the Deaf. This study examined the merits of using the TOEFL to measure the English reading ability of hearing post-secondary international students seeking admission to English-based colleges and universities. Forty-one hearing foreign students were tested in the fall of 1989 at the English Language Institute at SUNY Buffalo. The instruments chosen were both the TOEFL and the California Achievement Test of reading ability. The majority of the research subjects who scored between 400 and 500 on the TOEFL achieved a grade level of less than 8.0 on the California Achievement Test.

  15. Measuring the quality of child health care at first-level facilities.

    Science.gov (United States)

    Gouws, Eleanor; Bryce, Jennifer; Pariyo, George; Armstrong Schellenberg, Joanna; Amaral, João; Habicht, Jean-Pierre

    2005-08-01

    Sound policy and program decisions require timely information based on valid and relevant measures. Recent findings suggest that despite the availability of effective and affordable guidelines for the management of sick children in first-level health facilities in developing countries, the quality and coverage of these services remains low. We report on the development and evaluation of a set of summary indices reflecting the quality of care received by sick children in first-level facilities. The indices were first developed through a consultative process to achieve face validity by involving technical experts and policymakers. The definition of evaluation measures for many public health programs stops at this point. We added a second phase in which standard statistical techniques were used to evaluate the content and construct validity of the indices and their reliability, drawing on data sets from the multi-country evaluation of integrated management of childhood illness (MCE) in Brazil, Tanzania and Uganda. The statistical evaluation identified important conceptual errors in the indices arising from the theory-driven expert review. The experts had combined items into inappropriate indicators resulting in summary indices that were difficult to interpret and had limited validity for program decision making. We propose a revised set of summary indices for the measurement of child health care in developing countries that is supported by both expert and statistical reviews and that led to similar programmatic insights across the three countries. We advocate increased cross-disciplinary research within public health to improve measurement approaches. Child survival policymakers, program planners and implementers can use these tools to improve their monitoring and so increase the health impact of investments in health facility care.

  16. Target detection and driving behaviour measurements in a driving simulator at mesopic light levels

    NARCIS (Netherlands)

    Alferdinck, J.W.A.M.

    2006-01-01

    During night-time driving hazardous objects often appear at mesopic light levels, which are typically measured using light meters with a spectral sensitivity that is only valid for photopic light levels. In order to develop suitable mesopic models a target detection experiment was performed in a

  17. Measurements of Iodine Contents in Some Iodized Salts (Consumer Level) in (Myanmar)

    International Nuclear Information System (INIS)

    San Yee; Khin Yi; Sein Htoon

    2004-05-01

    The amount of iodine contents in iodized salt (consumer level) of six brands in Myanmar were measured by means of volumetric method (WHO recommended) and vibrational spectroscopic technique. The results optained from both methods were in good agreement within the statistical error

  18. Measurement and interpretation of low levels of dissolved oxygen in ground water

    Science.gov (United States)

    White, A.F.; Peterson, M.L.; Solbau, R.D.

    1990-01-01

    A Rhodazine-D colorimetric technique was adapted to measure low-level dissolved oxygen concentrations in ground water. Prepared samples containing between 0 and 8.0 ??moles L-1 dissolved oxygen in equilibrium with known gas mixtures produced linear spectrophotometric absorbance with a lower detection limit of 0.2 ??moles L-1. Excellent reproducibility was found for solutions ranging in composition from deionized water to sea water with chemical interferences detected only for easily reduced metal species such as ferric ion, cupric ion, and hexavalent chromium. Such effects were correctable based on parallel reaction stoichiometries relative to oxygen. The technique, coupled with a downhole wire line tool, permitted low-level monitoring of dissolved oxygen in wells at the selenium-contaminated Kesterson Reservoir in California. Results indicated a close association between low but measurable dissolved oxygen concentrations and mobility of oxidized forms of selenium. -from Authors

  19. Measurements of 222Rn and 226Ra Levels in environmental samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Moustafa, A.S.

    2004-01-01

    The advantageous of liquid scintillation counting technique for 6 Ra determination compared with other methods are the high counting efficiency and the easier sample preparation, with no need for sample pre-concentration. In this work, liquid scintillation counting system was used to measure 222 Rn and 226 Ra levels in environmental samples. The liquid scintillation cocktail was prepared in the laboratory and was found efficient for measuring 222 Rn. Soil, sediment and TENORM samples were dried, grind, sieved and added to hydrochloric acid, in a standard scintillation vial, preloaded with the liquid scintillation cocktail. By measuring 222 Rn levels in the prepared vials, at different intervals of time after preparation, 222 Rn and 226 Ra levels were determined

  20. Mutations at the Level of the Measures Adopted by Monetary Authorities

    Directory of Open Access Journals (Sweden)

    Stefan MATEI

    2012-08-01

    Full Text Available Following the intensification of the international financial crisis in autumn 2008, the functioning of the financial system was seriously hindered. Central banks around the world responded firmly by lowering their key interest rates to historically low levels. As financial conditions did not improve as hoped and the real economy was still unstable, revealing therefore the limits of mainstream monetary policy, many monetary authorities employed several unconventional measures. The scope of this paper is to investigate two important approaches of classifying “unorthodox” monetary policies and review several measures undertook by central banks, highlighting the impact and some of the possible risks to the contemporary economy.

  1. NEW APPROACHES: Measurement of the mean lifetime of cosmic ray muons in the A-level laboratory

    Science.gov (United States)

    Dunne, Peter; Costich, David; O'Sullivan, Sean

    1998-09-01

    The Turning Points in Physics module from the NEAB A-level Modular Physics syllabus requires students to have an understanding of relativistic time dilation and offers the measurement of the mean lifetime of cosmic ray muons as an example of supporting experimental evidence. This article describes a direct measurement of muon lifetime carried out in the A-level laboratory.

  2. A computerized system to measure interproximal alveolar bone levels in epidemiologic, radiographic investigations. II

    International Nuclear Information System (INIS)

    Wouters, F.R.; Frithiof, L.; Soeder, P.Oe.; Hellden, L.; Lavstedt, S.; Salonen, L.

    1988-01-01

    The study was aimed at analyzing intra- and inter-examiner variations in computerized measurement and in non-measurability of alveolar bone level in a cross-sectional, epidemiologic material. At each interproximal tooth surface, alveolar bone height in percentage of root length (B/R) and tooth length (B/T) were determined twice by one examiner and once by a second examiner from X5-magnified periapical radiographs. The overall intra- and inter-examiner variations in measurement were 2.85% and 3.84% of root length and 1.97% and 2.82% of tooth length, respectively. The varations were different for different tooth groups and for different degrees of severity of marginal periodontitis. The overall proportions on non-measurable tooth surfaces varied with examiner from 32% to 39% and from 43% to 48% of the available interproximal tooth surfaces for B/R and B/T, respectively. With regard to the level of reliability, the computerized method reported is appropriate to cross-sectional, epidemiologic investigations from radiographs

  3. Ultralow-level measurement of organically-bound tritium in bioassay samples

    International Nuclear Information System (INIS)

    Kotzer, T.; Trivedi, A.; Waito, G.; Workman, W.

    1998-12-01

    An intercomparison study of urine samples having high levels (5 Bq·L -1 ) of organically-bound tritium (OBT) was conducted, in conjunction with the oxygen combustion-liquid scintillation counting (LSC) method, to evaluate the suitability and sensitivity of the 3 He-ingrowth mass spectrometry (MS) technique for OBT in bioassay samples. The study established that 3 He ingrowth-MS has the required sensitivity to measure ultralow levels of OBT-in-urine (∼0.1 Bq·L -1 ). Cumulative 24 h urine samples from a few members of the general population, living in the vicinity of the heavy-water research reactor facility at Chalk River Laboratories (CRL) at Chalk River, were collected and analyzed for tritiated water (HTO) and OBT. The participants were from Ottawa (200 km east), Deep River (10 km west) and an occasionally occupationally HTO-exposed worker at CRL. HTO-in-urine values were 6.5 Bq·L -1 for the Ottawa resident, 15.8 Bq·L -1 for the Deep River resident, and 1260 Bq·L -1 for the exposed worker. OBT-in-urine levels from these same individuals were 0.06 Bq·L -1 (Ottawa), 0.29 Bq·L -1 (Deep River), and 2.2 Bq·L -1 (exposed worker). With a model developed for calculating OBT dose fraction from the measured ratio of HTO to OBT in urine, we estimated that the dose arising from OBT in the body was about 26% of the total tritium dose for the Ottawa resident and 50% for the Deep River resident. The CRL individual had a 5% dose contribution from OBT, but had higher overall tritium dose due to frequent intakes of HTO. The study indicates that the bulk of the tritium dose to the population is the result of HTO intakes and not due to dietary intake of OBT. (author)

  4. The measurement of serum TNF-α levels in patients with lichen planus.

    Science.gov (United States)

    Akpinar Kara, Yesim

    2017-12-01

    Lichen planus is a common mucocutaneous inflammatory skin disease with a multifactorial etiology. Cytokines play a key role in lichen planus pathogenesis. This study investigates the relationship between disease severity and levels of tumor necrosis factor-α (TNF-α), which is considered a primary cytokine that initiates cytotoxicity. Serum TNF-α levels were compared between a patient group (n = 34) and a control group (n = 20). TNF-α serum levels were measured using human TNF-α Enzyme-Linked Immunosorbent Assay (ELISA) test kits, and the two groups were statistically compared to each other. Mean serum TNF-α levels were found to be significantly higher in the patient group than in the control group (p 0.005). No relationship was detected between TNF-α levels and patients' sex. It is thought that TNF-α, a proinflammatory cytokine, may play an important role in the pathogenesis of lichen planus. TNF-α may be a simple and effective predictor to illustrate the inflammatory status in patients with lichen planus.

  5. The Development of a Tactical-Level Full Range Leadership Measurement Instrument

    Science.gov (United States)

    2010-03-01

    full range leadership theory has become established as the predominant and most widely researched theory on leadership . The most commonly used survey...instrument to assess full range leadership theory is the Multifactor Leadership Questionnaire, originally developed by Bass in 1985. Although much...existing literature to develop a new full range leadership theory measurement instrument that effectively targets low- to mid-level supervisors, or

  6. Measurement of gross beta radioactivity in high-level liquid waste

    International Nuclear Information System (INIS)

    Lu Feng; Lin Cansheng; Zhang Xianzi; Chen Guoan; Zhang Chonghai

    1992-01-01

    Using beta plastic scintillation counter of low level background, gross beta radioactivity of twelve samples for high-level liquid waste is determined directly. Beta efficiency curves of plastic scintillation counter for four mass thickness are calibrated in advance. Determining gross beta radioactivity, gross efficiency of the scintillation counter for various energy beta ray is calculated via weighted mean method with the ratio of radioactivity for each nuclide. The ratio of radioactivity for nuclides which have gamma disintegration is determined in terms of the radioactivity measured by gamma spectrometer. The ratio of the radioactivity for 90 Sr which has purity beta disintegration is calculated in terms of half life time approximation. The ratio of the radioactivity for 147 Pm which also has purity disintegration is calculated by means of apparent cooling-time approximation. The uncertainty of results for the present work is about +-15%

  7. Process and device for continuous measurement of the level of a radioactive glass melt

    International Nuclear Information System (INIS)

    Ritter, H.

    1987-01-01

    The glass melt runs into a high quality steel mould in the form of a jet at the bottom exit of the smelting furnace or reservoir. The smelting furnace or reservoir and the high quality steel mould can be made part of an electrical circuit by suitable insulation measures relative to one another and relative to the earth potential. The glass melt jet is used as a variable resistance in this circuit, as its resistance will decrease with its decreasing length due to the increasing level in the mould. The resistance is suitable as a direct measure of the level. (DG) [de

  8. Measuring total health inequality: adding individual variation to group-level differences

    Directory of Open Access Journals (Sweden)

    Gakidou Emmanuela

    2002-08-01

    Full Text Available Abstract Background Studies have revealed large variations in average health status across social, economic, and other groups. No study exists on the distribution of the risk of ill-health across individuals, either within groups or across all people in a society, and as such a crucial piece of total health inequality has been overlooked. Some of the reason for this neglect has been that the risk of death, which forms the basis for most measures, is impossible to observe directly and difficult to estimate. Methods We develop a measure of total health inequality – encompassing all inequalities among people in a society, including variation between and within groups – by adapting a beta-binomial regression model. We apply it to children under age two in 50 low- and middle-income countries. Our method has been adopted by the World Health Organization and is being implemented in surveys around the world; preliminary estimates have appeared in the World Health Report (2000. Results Countries with similar average child mortality differ considerably in total health inequality. Liberia and Mozambique have the largest inequalities in child survival, while Colombia, the Philippines and Kazakhstan have the lowest levels among the countries measured. Conclusions Total health inequality estimates should be routinely reported alongside average levels of health in populations and groups, as they reveal important policy-related information not otherwise knowable. This approach enables meaningful comparisons of inequality across countries and future analyses of the determinants of inequality.

  9. State background-radiation levels: results of measurements taken during 1975-1979

    International Nuclear Information System (INIS)

    Myrick, T.E.; Berven, B.A.; Haywood, F.F.

    1981-11-01

    Background radiation levels across the United States have been measured by the Off-Site Pollutant Measurements Group of the Health and Safety Research Division at Oak Ridge National Laboratory (ORNL). These measurements have been conducted as part of the ORNL program of radiological surveillance at inactive uranium mills and sites formerly utilized during Manhattan Engineer District and early Atomic Energy Commission projects. The measurements included determination of 226 Ra, 232 Th, and 238 U concentrations in surface soil samples and measurement of external gamma-ray exposure rates at 1 m above the ground surface at the location of soil sampling. This information is being utilized for comparative purposes to determine the extent of contamination present at the survey sites and surrounding off-site areas. The sampling program to date has provided background information at 356 locations in 33 states. External gamma-ray exposure rates were found to range from less than 1 to 34 μR/h, with an US average of 8.5 μR/h. The nationwide average concentrations of 226 Ra, 232 Th, and 238 U in surface soil were determined to be 1.1, 0.98, and 1.0 pCi/g, respectively

  10. Low level alpha activity measurements with pulse shape discrimination

    International Nuclear Information System (INIS)

    Noguchi, Masayasu; Satoh, Kaneaki; Higuchi, Hideo.

    1984-01-01

    Pulse shape discrimination of α and β rays with liquid scintillation counting was investigated for the purpose of low level α activity measurements. Various liquid scintillators for pulse shape discrimination were examined by means of pulse rise time analysis. A new scintillator of low cost and of superior characteristics was found. The figure of merits better than 3.5 in risetime spectrum and the energy resolution better than 9% were obtained for carefully prepared samples. The background counting rate for a sample of 10 ml was reduced to 0.013 cpm/MeV in the range of α ray energy 5 to 7 MeV. (author)

  11. Measurement of extremely low level dose with LiF(Mg,Cu,P) TL chips

    International Nuclear Information System (INIS)

    Zha Ziying; Wang Shoushan; Wu Fang; Chen Guolong; Li Yuanfang; Zhu Jianhuan

    1986-01-01

    This paper presents some of the dosimetric characteristics of newly developed LiF(Mg,Cu,P) TL chips with high signal-to-noise ratio for measurement at the 10 -7 to 10 -4 Gy dose level. Measuring techniques and optimum procedures for annealing and readout are also presented. (author)

  12. Autonomy dimensions and care seeking for delivery in Zambia; the prevailing importance of cluster-level measurement.

    Science.gov (United States)

    Gabrysch, Sabine; McMahon, Shannon A; Siling, Katja; Kenward, Michael G; Campbell, Oona M R

    2016-03-02

    It is widely held that decisions whether or when to attend health facilities for childbirth are not only influenced by risk awareness and household wealth, but also by factors such as autonomy or a woman's ability to act upon her own preferences. How autonomy should be constructed and measured - namely, as an individual or cluster-level variable - has been less examined. We drew on household survey data from Zambia to study the effect of several autonomy dimensions (financial, relationship, freedom of movement, health care seeking and violence) on place of delivery for 3200 births across 203 rural clusters (villages). In multilevel logistic regression, two autonomy dimensions (relationship and health care seeking) were strongly associated with facility delivery when measured at the cluster level (OR 1.27 and 1.57, respectively), though not at the individual level. This suggests that power relations and gender norms at the community level may override an individual woman's autonomy, and cluster-level measurement may prove critical to understanding the interplay between autonomy and care seeking in this and similar contexts.

  13. Autonomy dimensions and care seeking for delivery in Zambia; the prevailing importance of cluster-level measurement

    Science.gov (United States)

    Gabrysch, Sabine; McMahon, Shannon A.; Siling, Katja; Kenward, Michael G.; Campbell, Oona M. R.

    2016-01-01

    It is widely held that decisions whether or when to attend health facilities for childbirth are not only influenced by risk awareness and household wealth, but also by factors such as autonomy or a woman’s ability to act upon her own preferences. How autonomy should be constructed and measured – namely, as an individual or cluster-level variable – has been less examined. We drew on household survey data from Zambia to study the effect of several autonomy dimensions (financial, relationship, freedom of movement, health care seeking and violence) on place of delivery for 3200 births across 203 rural clusters (villages). In multilevel logistic regression, two autonomy dimensions (relationship and health care seeking) were strongly associated with facility delivery when measured at the cluster level (OR 1.27 and 1.57, respectively), though not at the individual level. This suggests that power relations and gender norms at the community level may override an individual woman’s autonomy, and cluster-level measurement may prove critical to understanding the interplay between autonomy and care seeking in this and similar contexts. PMID:26931301

  14. Assessment of an ultrasonic sensor and a capacitance probe for measurement of two-phase mixture level

    International Nuclear Information System (INIS)

    Kim, Chang Hyun; Lee, Dong Won; No, Hee Cheon

    2004-01-01

    We perform a comparison of two-phase mixture levels measured by an ultrasonic sensor and a two-wire type capacitance probe with visual data under the same experimental conditions. A series of experiments are performed with various combinations of airflow and initial water level using a test vessel with a height of 2m and an inner diameter of 0.3 m under atmospheric pressure and room temperature. The ultrasonic sensor measures the two-phase mixture level with a maximum error of 1.77% with respect to the visual data. The capacitance probe severely under-predicts the level data in the high void fraction region. The cause of the error is identified as the change of the dielectric constant as the void fraction changes when the probe is applied to the measurement of the two-phase mixture levels. A correction method for the capacitance probe is proposed by correcting the change of dielectric constant of the two-phase mixture. The correction method for the capacitance probe produces a r.m.s. error of 5.4%. (author)

  15. Environmental tobacco smoke exposure among non-smoking waiters: measurement of expired carbon monoxide levels

    Directory of Open Access Journals (Sweden)

    Ronaldo Laranjeira

    2000-07-01

    Full Text Available CONTEXT: Exposure to environmental tobacco smoke is a health risk that is of concern to patrons and of particular concern to employees of restaurants and bars. OBJECTIVE: To assess environmental tobacco smoke exposure (using expired carbon monoxide levels in non-smoking waiters before and after a normal day's shift and to compare pre-exposure levels with non-smoking medical students. DESIGN: An observational study. SETTING: Restaurants with more than 50 tables or 100 places in São Paulo. SUBJECTS: 100 non-smoking restaurant waiters and 100 non-smoking medical students in São Paulo, Brazil. MAIN MEASUREMENTS: Levels of expired carbon monoxide, measured with a Smokerlyser (Bedfont EC 50 Scientific, before and after a normal day's work. RESULTS: Waiters' pre-exposure expired carbon monoxide levels were similar to those of medical students, but after a mean of 9 hours exposure in the workplace, median levels more than doubled (2.0 ppm vs. 5.0 ppm, P <0.001. Post-exposure carbon monoxide levels were correlated with the number of tables available for smokers (Kendall's tau = 0.2, P <0.0001. CONCLUSIONS: Exposure to environmental tobacco smoke is the most likely explanation for the increase in carbon monoxide levels among these non-smoking waiters. These findings can be used to inform the ongoing public health debate on passive smoking.

  16. Measurements of the ionising radiation level at a nuclear medicine facility performing PET/CT examinations

    International Nuclear Information System (INIS)

    Tulik, P.; Kowalska, M.; Golnik, N.; Budzynska, A.; Dziuk, M.

    2017-01-01

    This paper presents the results of radiation level measurements at workplaces in a nuclear medicine facility performing PET/ CT examinations. This study meticulously determines the staff radiation exposure in a PET/CT facility by tracking the path of patient movement. The measurements of the instantaneous radiation exposure were performed using an electronic radiometer with a proportional counter that was equipped with the option of recording the results on line. The measurements allowed for visualisation of the staff's instantaneous exposure caused by a patient walking through the department after the administration of "1"8F-FDG. An estimation of low doses associated with each working step and the exposure during a routine day in the department was possible. The measurements were completed by determining the average radiation level using highly sensitive thermoluminescent detectors. (authors)

  17. Rapid Word Recognition as a Measure of Word-Level Automaticity and Its Relation to Other Measures of Reading

    Science.gov (United States)

    Frye, Elizabeth M.; Gosky, Ross

    2012-01-01

    The present study investigated the relationship between rapid recognition of individual words (Word Recognition Test) and two measures of contextual reading: (1) grade-level Passage Reading Test (IRI passage) and (2) performance on standardized STAR Reading Test. To establish if time of presentation on the word recognition test was a factor in…

  18. Technical report on levels of electromagnetic fields created by Linky meters. Part 1: laboratory measurements; Part 2: laboratory additional measurements; Part 3: field measurements

    International Nuclear Information System (INIS)

    2016-05-01

    The first part of this study reports measurements of electromagnetic radiations induced by remote-metering reading devices present in new power meters and using the Power-Line Communication (PLC or, in French, CPL) technology, such as the Linky meter. After a recall of legislation regarding exposure to electromagnetic waves, this first part present the two tested meters (Linky of first and third generation, G1 and G3), the performed tests, measurements devices and method. It more precisely reports investigations performed on these both meters, and a comparison with other home appliances. The second part reports additional measurements performed with both meters according to the same methodology, but with the use of a new electric field probe which allows more precise measurements. Maximum electric and magnetic fields have been measured. The third part reports field measurements performed with the same methodology but in dwellings equipped with Linky meters of first generation (G1). Exposure levels have been measured at the vicinity of meters and in other parts of the dwelling

  19. Experimental Investigation of Liquid-Level Measuring Accuracy in a Low Pressure Environment

    International Nuclear Information System (INIS)

    Adamson, D.J.

    1996-10-01

    Dip Tubes which are used for determining liquid level in many processes at SRS will be used to measure the liquid level of the Am/Cm solution in the Feed Tank at the MPPF. The Feed Tank operates under a vacuum, therefore the Dip Tubes will operate under a vacuum. Uncertainty in how accurate the Dip Tubes would perform in a vacuum environment led to testing. The Am/Cm Melter Liquid-Feed Tank measurement test was mocked-up per Figure 1. The Feed Tank was designed to simulate actual conditions in which the Dip Tubes would measure the differential pressure. The Feed Tank was made of Stainless Steel with a Lexan window to view inside the tank during testing. The Feed Tank was built per Drawing SRT-ETF-DD-96008, Revision A. The accuracy of the Dip Tubes was checked first by filling the Feed Tank at a flow rate of 3.5 L/min and venting it to the atmosphere. Figure 2 shows that the Dip Tubes were responsive and accurate when compared to the data from the measuring scale on the view window. Then tests were conducted with 23y Hg vacuum inside the tank and water flow rates of 3.9 L/min, 1.8 L/min, and 0.7 L/min being fed to the tank. The data from each test are depicted in Figure 3, Figure 4, and Figure 5, respectively. The Dip Tubes responded accurately for the three test with a maximum error range of +0.31y to -0.19y when compared to the measuring scale located next to the view window on the Feed Tank

  20. Association between self-reported and objectively measured physical fitness level in a middle-aged population in primary care

    DEFF Research Database (Denmark)

    Obling, Kirstine H.; Hansen, Anne-Louise Smidt; Overgaard, Kristian

    2015-01-01

    fitness level were cross-tabulated and agreement was quantified by Kappa statistics. Gender differences within categories were investigated by Poisson regression. RESULTS: Data from 996 men and 1017 women were analyzed (excluded, n = 303). In both men and women a higher self-reported fitness level......AIM: To investigate the association between self-reported physical fitness level obtained by a single-item question and objectively measured fitness level in 30- to 49-year-old men and women. METHODS: From the Danish 'Check Your Health Preventive Program' 2013-2014 fitness level was assessed...... in 2316 participants using the Aastrand test. Additionally, participants rated their physical fitness as high, good, average, fair or low. The association of self-reported- with objectively measured fitness level was analyzed by linear regression. Categories of self-reported- and objectively measured...

  1. Electrooptic Methods for Measurement of Small DC Currents at High Voltage Level

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Beatty, Neville; Skilbreid, Asbjørn Ottar

    1989-01-01

    collectors are connected via resistors RA and RB to the protective side of the voltage to be measured and the emitters to the negative side. The currents flowing in to the bases of the transistors are independently controlled by the light levels following on the two photodiodes PDA, PDB....

  2. A research on determination of input levels used in fair value measurement hierarchy by firms listed in Borsa Istanbul

    OpenAIRE

    Gokgoz, Ahmet; Senturk, Fatih

    2015-01-01

    With the coming into force of TFRS 13 Fair Value Measurement Standard, the inputs which firms use for determination of fair value measurement are classified into three levels and hierarchy of determination of fair value is constituted. This standard requires increasing level 1 inputs and decreasing level 3 inputs in determination of fair value. With this study fair value measurement levels (hierarchy) which are used in determination of fair value are described within the scope of TFRS 13 Fair...

  3. Highest PBDE levels (max 63 ppm) yet found in biota measured in seabird eggs from San Francisco Bay

    Energy Technology Data Exchange (ETDEWEB)

    She, J.; Holden, A.; Tanner, M.; Sharp, M.; Hooper, K. [Department of Toxic Substances Control, Berkeley, CA (United States). Hazardous Materials Lab.; Adelsbach, T. [Environmental Contaminants Division, Sacramento Fish and Wildlife Office, US Fish and Wildlife Service, Sacramento, CA (United States)

    2004-09-15

    High levels of polybrominated diphenylethers (PBDEs) have been found in humans and wildlife from the San Francisco Bay Area, with levels in women among the highest in the world, and levels in piscivorous seabird eggs at the ppm level. Seabirds are useful for monitoring and assessing ecosystem health at various times and places because they occupy a high trophic level in the marine food web, are long-lived, and are generally localized near their breeding and non-breeding sites. In collaboration with the US Fish and Wildlife Services (USFWS), we are carrying out a three-year investigation of dioxin, PCB and PBDE levels in eggs from fish-eating seabirds. Year 1 (2002) PBDE measurements from 73 bird eggs were reported at Dioxin2003. Year 2 (2003) PBDE measurements from 45 samples are presented in this report. The highest PBDE level measured in eggs was 63 ppm, lipid, which is the highest PBDE level, yet reported in biota.

  4. Adiponectin levels measured in dried blood spot samples from neonates born small and appropriate for gestational age

    DEFF Research Database (Denmark)

    Klamer, A; Skogstrand, Kristin; Hougaard, D M

    2007-01-01

    Adiponectin levels measured in neonatal dried blood spot samples (DBSS) might be affected by both prematurity and being born small for gestational age (SGA). The aim of the study was to measure adiponectin levels in routinely collected neonatal DBSS taken on day 5 (range 3-12) postnatal from...

  5. Measurement of health system performance at district level: A study protocol

    Directory of Open Access Journals (Sweden)

    Atul Sharma

    2018-01-01

    Full Text Available Background: Limited efforts have been observed in low and middle income countries to undertake health system performance assessment at district level. Absence of a comprehensive data collection tool and lack of a standardised single summary measure defining overall performance are some of the main problems. Present study has been undertaken to develop a summary composite health system performance index at district level. Methods: A broad range of indicators covering all six domains as per building block framework were finalized by an expert panel. The domains were classified into twenty sub-domains, with 70 input and process indicators to measure performance. Seven sub-domains for assessing health system outputs and outcomes were identified, with a total of 28 indicators. Districts in Haryana state from north India were selected for the study. Primary and secondary data will be collected from 378 health facilities, district and state health directorate headquarters. Indicators will be normalized, aggregated to generate composite performance index at district level. Domain specific scores will present the quality of individual building block domains in the public health system. Robustness of the results will be checked using sensitivity analysis. Expected impact for public health: The study presents a methodology for comprehensive assessment of all health system domains on basis of input, process, output and outcome indicators which has never been reported from India. Generation of this index will help identify policy and implementation areas of concern and point towards potential solutions. Results may also help understand relationships between individual building blocks and their sub-components.

  6. Quarterly report on measurements of radionuclides in ground level air in Sweden. Third quarter 2004

    International Nuclear Information System (INIS)

    Soederstroem, C.; Arntsing, R.; Lindh, K.

    2005-04-01

    Filtering of ground level air is performed weekly at six different locations in Sweden: Kiruna, Umeaa, Gaevle, Ursvik, Visby and Ljungbyhed. The filters are pressed and the contents of different radionuclides are measured by gamma spectroscopy. Precipitation is also collected at four of the stations: Kiruna, Gaevle, Ursvik and Ljungbyhed, the samples are ashed and the contents of radionuclides measured. The levels of 7 Be and 137 Cs in air and deposition are presented for the different stations. Other anthropogenic radionuclides detected, if any, are also presented

  7. Factors Influencing the Measurement of Plasma/Serum Surfactant Protein D Levels by ELISA

    OpenAIRE

    Bratcher, Preston E.; Gaggar, Amit

    2014-01-01

    BACKGROUND: Extensive variations in human surfactant protein D (SP-D) levels in circulation as measured by ELISA exist in the published literature. In order to determine the source of these variations, factors influencing the measurement by ELISA were explored. MATERIALS AND METHODS: Peripheral blood from healthy individuals was collected into various vacutainers during the same blood draw. Recombinant SP-D was diluted into different matrices and used for a standard curve. Samples were analyz...

  8. MEASURING THE LEVEL OF TOURIST SATISFACTION. CASE STUDY BRASOV COUNTY

    Directory of Open Access Journals (Sweden)

    Gabriel Bratucu

    2017-05-01

    Full Text Available The objective of this paper is to measure the satisfaction level of Romanian and foreign tourists visiting Brașov. In order to achieve the above mentioned objective, a survey was carried out on a sample of 1,119 visitors to Brașov County. This quantitative research is part of a project entitled Destination Intelligent Management for Sustainable Tourism, won following a national competition. These findings can be used by businesses and the local managing authorities in establishing the strategies for the sustainable development of tourism in the in the region.

  9. Measurement of plasma 11-deoxycorticosterone levels by radioimmunoassay in man

    International Nuclear Information System (INIS)

    Fukuchi, Soitsu; Nakajima, Katsuo; Takenouchi, Takahiko; Nishisato, Koji

    1974-01-01

    A radioimmunoassay procedure has been developed to measure 11-deoxycorticosterone (DOC) in human peripheral plasma. DOC-oxime was coupled with porcine gamma globulin and antibodies produced in rabbits. One to 3 ml of plasma, with 1, 2 3 H-DOC added for recovery, was extracted with dichloromethane and purification achieved by a silica gel column and by one paper chromatograph. After overnight incubation of the antibody-steroid mixture at 4 0 C, bound and free fractions were separated using ammonium sulfate. The mean recovery of 3 H-DOC, after extraction and chromatography, was 84.6 +- 7.4%. The method showed adequate specificity, precision and accuracy. Normal plasma DOC levels were found to be 4.4 +- 2.5 ng/100 ml (n=8). Plasma DOC levels were almost normal (0.3 - 26.8 ng/100 ml) in fifteen patients with benign essential hypertension. The mean level of 8.1 +- 8.2 ng/100 ml obtained in hypertensive patients with suppressed plasma renin activity, was not significantly different from normal. Plasma DOC showed a high level, 3.0 - 30.5 (11.4 +- 7.5) ng/100 ml, in 9 patients with primary aldosteronism. Four out of 8 patients with Cushing's syndrome were found to have elevated plasma DOC levels. Higher levels of 21.2 +- 15.8 ng/100 ml were found in 5 patients with adrenal hyperplasia than those of 12.3 +- 8.0 ng/100 ml in 3 with adrenal adenoma. Plasma DOC levels were high, 113 - 176 ng/100 ml, in 2 patients with 17α-hydroxylase deficiency. ACTH administered to 5 subjects produced a mean increase in plasma DOC from 4.8 to 25.8 ng/100 ml. Angiotensin II infused at a rate of 10 ng/kg/min for 30 min into 4 subjects did not increase mean plasma DOC. Similarly, dietary sodium restriction or postural change did not increase plasma DOC. (auth.)

  10. Excited-level lifetimes and hyperfine-structure measurements on ions using collinear laser--ion-beam spectroscopy

    International Nuclear Information System (INIS)

    Jin, J.; Church, D.A.

    1994-01-01

    The mean lifetimes τ of the Ca II 4p 2 P 1/2 and 4p 2 P 3/2 levels, and the 35 Cl II 4p' 1 F 3 level, have been measured by a variant of the collinear laser--ion-beam lifetime technique applied previously to the Ar II 4p' 2 F 7/2 o level [Jian Jin and D. A. Church, Phys. Rev. A 47, 132 (1993)]. The present results are τ(Ca II, 4p 2 P 1/2 )=7.098(0.020) ns, τ(Ca II, 4p 2 P 3/2 )=6.924(0.019) ns, and τ(Cl II, 4p' 1 F 3 ) =11.17(0.06) ns. The experimental lifetimes of these, plus the Ar II 4p' 2 F 7/2 level, are compared with available recent many-electron calculations. Typically 1%--3% differences between measurement and ab initio theory are found, while certain semiempirical calculations are in better agreement with experiment. Data for other precise lifetime measurements on alkali-metal systems are compared with recent ab initio and semiempirical calculations to provide perspective on the Ca II results. The hyperfine structure of the 35 Cl II 3d' 1 G 4 --4p' 1 F 3 transition was also measured and analyzed in the course of the measurements, with the resulting hyperfine-structure constants: A( 1 F 3 )=301.9(0.5) MHz, B( 1 F 3 )=-6.7(0.8) MHz, A( 1 G 4 )=205.1(0.5) MHz, and B( 1 G 4 )=-3.9(2.4) MHz

  11. Methods of measuring the level of logistics serving in international business

    Directory of Open Access Journals (Sweden)

    Simona BĂLĂŞESCU

    2015-06-01

    Full Text Available This paper raise the issue of logistics service of customers in international markets. The study aims optimizing logistics serving using the case of a company in Romania which has several foreign customers. The main objectives of the investigation are related to the measurement of logistic service level for the company’s foreign clients and to an evaluation of the present potential of the logistic serving strategy of this company. The instruments used for the analysis are the economic outputs, information from foreign customers and the theory about the level of logistic serving. The results of the analysis are used for making a proposal of a set of projects aiming the improvement of the serving quality of foreign customers.

  12. Methods and measurements of indoor levels of radon and its daughter products

    International Nuclear Information System (INIS)

    Subba Ramu, M.C.; Muraleedharan, T.S.; Ramachandran, T.V.; Shaikh, G.N.

    1988-01-01

    General population is exposed, some times, to enhanced levels of radon (Rn) and its progeny concontrations in the indoor environment of dwellings, depending on various parameters like type of construction, location and ventilation features of the dwelling as well as on the occupancy factor. The risk involved in the indoor Rn exposure is briefly discussed in this report. Several methods are available for the measurement of Rn and its daughters in dwellings. This report describes in detail some of the suitable and convenient methods for the measurements. Methods for evluating ventilation rate in dwellings is also given. Grab sampling and time integrated measurements are described. The report also gives the results of some preliminary measurements carried out in some rooms and lecture halls of the Bhabha Atomic Research Centre, Bombay. The results are discussed and conclusions drawn with particular reference to a country-wide survey of Rn exposure. (author)

  13. Pressure sound level measurements at an educational environment in Goiania, Goias, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Jhonatha J.L.; Nascimento, Eriberto O. do; Oliveira, Lucas N. de [Instituto Federal de Educação, Ciência e Tecnologia de Goiás (IFG), Goiânia, GO (Brazil); Caldas, Linda V. E., E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    In this work, twenty five points located on the ground floor of the Federal Institute of Education, Science and Technology of Goias - IFG - Campus Goiania, were analyzed in morning periods of two Saturdays. The pressure sound levels were measured at internal and external environments during routine activities seeking to perform an environmental monitoring at this institution. The initial hypothesis was that an amusement park (Mutirama Park) was responsible for originating noise pollution in the institution, but the results showed, within the campus environment, sound pressure levels in accordance with the Municipal legislation of Goiania for all points. (author)

  14. Pressure sound level measurements at an educational environment in Goiania, Goias, Brazil

    International Nuclear Information System (INIS)

    Costa, Jhonatha J.L.; Nascimento, Eriberto O. do; Oliveira, Lucas N. de; Caldas, Linda V. E.

    2017-01-01

    In this work, twenty five points located on the ground floor of the Federal Institute of Education, Science and Technology of Goias - IFG - Campus Goiania, were analyzed in morning periods of two Saturdays. The pressure sound levels were measured at internal and external environments during routine activities seeking to perform an environmental monitoring at this institution. The initial hypothesis was that an amusement park (Mutirama Park) was responsible for originating noise pollution in the institution, but the results showed, within the campus environment, sound pressure levels in accordance with the Municipal legislation of Goiania for all points. (author)

  15. Measuring a Level of Water Pollution in Sungai Pinang Using a Mathematical Model

    OpenAIRE

    Mahamud, Mohd Amirul; Ramasamy, Rajasegeran

    2013-01-01

    Mathematical models are now a popular tool in many applications such as physics, economics and engineering; and provide useful information for decision making and planning. Water pollution in Malaysia has reached a level that needs attention and intervention from environmental department and government. In order to make a strong case, this paper has done a study on measuring the pollution level of Sungai Pinang which is located in Penang Island, Malaysia. Advection-Dispersion equation is one ...

  16. Quarterly report on measurements of radionuclides in ground level air in Sweden. Third quarter 2001

    International Nuclear Information System (INIS)

    Soederstroem, C.; Arntsing, R.; Vintersved, I.

    2002-01-01

    Filtering of ground level air is performed weekly at seven different locations in Sweden: Kiruna, Umeaa, Gaevle, Ursvik, Grindsjoen, Visby and Ljungbyhed. The filters are compressed and the contents of different radionuclides are measured by gamma spectroscopy. Precipitation is also collected at four of the stations: Kiruna, Gaevle, Ursvik and Ljungbyhed, the samples are ashed and the contents of radionuclides measured. The levels of 7 Be and 137 Cs in air and deposition are presented for the different stations. Other anthropogenic radionuclides detected, if any, are also presented

  17. Measurement of the Radiative Decay of the Longest-Lived Level in the Fe XVII Spectrum

    Science.gov (United States)

    Brown, Gregory V.; Beiersdorfer, Peter; Träbert, Elmar

    2014-08-01

    The Fe XVII emission spectrum comprises several very prominent X-ray lines that play an important role in the study of many astrophysical objects. Among the Fe XVII X-ray lines, those emanating from a 3s level, i.e., lines 3F, 3G, and M2, invariably appear too strong compared to the lines emanating from a 3d level, i.e., lines 3C and 3D, when compared to theory. Two of the four 3s levels are metastable, which means they have a rather long radiative decay time compared to collisional processes. The decay rate of the 2p^53s J=2 level has recently been measured at the Livermore EBIT facility [J. R. Crespo López-Urrutia and P. Beiersdorfer, ApJ 721, 576 (2010)], and the scatter of predictions by a factor of 1.7 has been reduced to a measurement uncertainty of merely a few percent. Even longer-lived is the J=0 level of the same 2p^53s configuration. Theory predicts an exclusive magnetic dipole decay to the lowest J=1 level of the same 2p^53s configuration, i.e. to the upper level of line 3G. There appear to be fewer predictions for this rate than for the rates associated with the other Fe XVII levels. Various calculations yield a decay rate near 16 000 s-1 for this level (or a level lifetime near 63 µs). If this value is correct, electron-impact collisions affect line ratios tied to this level at densities between about 10^10 cm-3 and 10^13 cm-3, that is, exactly at many coronal densities of present interest. We have used the Livermore EBIT facility to measure the M1 decay rate of the 2p^53s J=0 level. We find a value commensurate with the value predicted by the Flexible Atomic Code.Work performed under auspices of U.S. D.o.E. by DE-AC52-07NA27344 and supported by NASA's APRA progam under Interagency Agreement NNG13WF991.

  18. Towards an interpretive measurement framework to assess the levels of integrated and integrative thinking within organisations

    Directory of Open Access Journals (Sweden)

    Daniel Schörger

    2015-07-01

    Full Text Available This research study is located within the context of corporate reporting and is relevant for the agenda of sustainability and sustainable development. The specific context for this study is the South African mining industry, within which three units in the form of three companies, were chosen to provide a coherent case for this study. The sample for the analysis is based on the integrated reports of these companies for the years 2012 and 2013. This gives this research a total sample size of six reports. Based on the research findings an initial interpretive measurement framework to assess the levels of capital integration has been theorised which enables the various stakeholders of an organisation to assess the integrated and integrative thinking capabilities. The level of integration is represented as a maturity scale on which integrated thinking is associated with the lower levels, while integrative thinking is attributed to higher levels of maturity. In the elaborated framework, integrated thinking is perceived as being a prerequisite for integrative thinking. The practical implication of this study is that it provides a potential measurement framework for various organisational stakeholders, including investors, to assess the thinking capabilities that are more likely to lead to long term financial stability and sustainability. The value of this research study is that it provides an initial step towards measuring the level of integrated and integrative thinking capabilities within organisations where no such measurement framework currently exists. The limitations and implications of this research study are that the interpretive measurement framework represents merely an initial step and an ongoing working hypothesis which requires further research to develop its maturity and usefulness.

  19. Biosafety and biosecurity measures: management of biosafety level 3 facilities.

    Science.gov (United States)

    Zaki, Adel N

    2010-11-01

    With the increasing biological threat from emerging infectious diseases and bioterrorism, it has become essential for governments around the globe to increase awareness and preparedness for identifying and containing those agents. This article introduces the basic concepts of laboratory management, laboratory biosafety and laboratory biosecurity. Assessment criteria for laboratories' biorisk should include both biosafety and biosecurity measures. The assessment requires setting specific goals and selecting management approaches. In order to implement technologies at the laboratory working level, a management team should be created whose role is to implement biorisk policies, rules and regulations appropriate for that facility. Rules and regulations required by government authorities are presented, with special emphasis on methods for air control, and liquid and solid waste management. Management and biorisk measures and appropriate physical facilities must keep pace, ensuring efficient facilities that protect workers, the environment, the product (research, diagnostic and/or vaccine) and the biological pathogen. Published by Elsevier B.V.

  20. Velocity flow field and water level measurements in shoaling and breaking water waves

    CSIR Research Space (South Africa)

    Mukaro, R

    2010-01-01

    Full Text Available In this paper we report on the laboratory investigations of breaking water waves. Measurements of the water levels and instantaneous fluid velocities were conducted in water waves breaking on a sloping beach within a glass flume. Instantaneous water...

  1. A comparison of disturbance levels measured in hypersonic tunnels using a hot-wire anemometer and a pitot pressure probe.

    Science.gov (United States)

    Stainback, P. C.; Wagner, R. D.

    1972-01-01

    Disturbance levels were measured in the test section of a Mach 5 blowdown jet using a constant-current, hot-wire anemometer and a pressure transducer. The disturbance levels, measured by the two instruments and normalized by local mean values, agreed within about 30%, with the pitot data higher than the hot-wire data. The rms disturbance levels measured with the hot-wire anemometer and converted to pitot pressures using a quasi-steady flow analysis, were about two-thirds the levels measured with the pitot probe. The variation of the normalized rms disturbance levels with stagnation pressure indicated that transition occurred in the boundary layer on the nozzle wall and influenced the outputs of the instruments located at the exit of the nozzle when the total pressure was about 35 N/sq cm. Below this pressure the disturbance levels decreased markedly. At higher pressures the disturbances were predominantly aerodynamic noise generated by the turbulent boundary layer on the nozzle wall.

  2. PROMETHEE: a versatile R and D measurement device for low level waste assay

    International Nuclear Information System (INIS)

    Romeyer Dherby, J.; Passard, C.; Mariani, A.

    1996-01-01

    The accurate measurement of heavy nuclide masses and activities in radioactive wastes drums is an important part of waste management. The Active/Passive non destructive assay of radioactive waste drums using a 14 MeV neutron generator is particularly interesting for alpha low level measurements or for gamma irradiating wastes. The development, optimisation, and validation of such a device for industrial use necessitate the building of a demonstrator. In 1985, the CEA decided to build at Cadarache the PROMETHEE modular system for experimenting the pulsed generator techniques, and since then, this device has led us to define several specific systems. At the present time, in the frame of COGEMA actions to reduce the volume of the reprocessing waste, a new strategy of drumming and incineration is going to start at LA HAGUE and MARCOULE, for the low level waste planned for surface storage. This strategy depends on the performance improvement of non destructive measurements systems used for the alpha waste evaluation. In this goal, a developments and tests are carried out on the PROMETHEE research and development facility at CEA CADARACHE, in order to obtain the required performances

  3. PROMETHEE: a versatile R and D measurement device for low level waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Romeyer Dherby, J.; Passard, C.; Mariani, A

    1996-12-31

    The accurate measurement of heavy nuclide masses and activities in radioactive wastes drums is an important part of waste management. The Active/Passive non destructive assay of radioactive waste drums using a 14 MeV neutron generator is particularly interesting for alpha low level measurements or for gamma irradiating wastes. The development, optimisation, and validation of such a device for industrial use necessitate the building of a demonstrator. In 1985, the CEA decided to build at Cadarache the PROMETHEE modular system for experimenting the pulsed generator techniques, and since then, this device has led us to define several specific systems. At the present time, in the frame of COGEMA actions to reduce the volume of the reprocessing waste, a new strategy of drumming and incineration is going to start at LA HAGUE and MARCOULE, for the low level waste planned for surface storage. This strategy depends on the performance improvement of non destructive measurements systems used for the alpha waste evaluation. In this goal, a developments and tests are carried out on the PROMETHEE research and development facility at CEA CADARACHE, in order to obtain the required performances.

  4. The DSM-5 Self-Rated Level 1 Cross-Cutting Symptom Measure as a Screening Tool.

    Science.gov (United States)

    Bastiaens, Leo; Galus, James

    2018-03-01

    The DSM-5 Self-Rated Level 1 Cross-Cutting Symptom Measure was developed to aid clinicians with a dimensional assessment of psychopathology; however, this measure resembles a screening tool for several symptomatic domains. The objective of the current study was to examine the basic parameters of sensitivity, specificity, positive and negative predictive power of the measure as a screening tool. One hundred and fifty patients in a correctional community center filled out the measure prior to a psychiatric evaluation, including the Mini International Neuropsychiatric Interview screen. The above parameters were calculated for the domains of depression, mania, anxiety, and psychosis. The results showed that the sensitivity and positive predictive power of the studied domains was poor because of a high rate of false positive answers on the measure. However, when the lowest threshold on the Cross-Cutting Symptom Measure was used, the sensitivity of the anxiety and psychosis domains and the negative predictive values for mania, anxiety and psychosis were good. In conclusion, while it is foreseeable that some clinicians may use the DSM-5 Self-Rated Level 1 Cross-Cutting Symptom Measure as a screening tool, it should not be relied on to identify positive findings. It functioned well in the negative prediction of mania, anxiety and psychosis symptoms.

  5. Measurement of ERP Utilization Level of Enterprises: The Sample of Province Aydın

    Directory of Open Access Journals (Sweden)

    Özel Sebetci

    2014-06-01

    Full Text Available The aim of this study is to measure ERP usage level of enterprises in Aydın. Data was obtained from 83 enterprises in Aydın via questionnaires. Data analysis showed that the enterprises had mostly high level of the computer integration and technologies on production. However, it was found that these enterprises did not use ERP systemsat high levels. Correlations between enterprise size by the number of employees, company revenue at 2012 and ERP usage levels were established by chi square test. Correlation analysis showed that there was a significant and positive correlation between ERP characteristics and strategic advantages about ERP.

  6. Experimental Measures of Bus Comfort Levels Using Kinematic Parameters Recorded by Smartphone

    Energy Technology Data Exchange (ETDEWEB)

    Aquila, S. dell' ; Eboli, L.; Futia, G.; Mazzulla, G.; Pungillo, G.

    2016-07-01

    Comfort on board plays an essential role in the levels of satisfaction of a bus service perceived by passengers. The aim of this paper is to propose a measure of comfort based on two kinds of data: perceptions of passengers (subjective data) and accelerations of bus (objective data). For the collection of subjective data a questionnaire was addressed to a sample of university students, while a smartphone, equipped with GPS device and 3-axis accelerometer, was used to record the accelerations. Based on the recorded parameters, we determined the thresholds of the acceleration values beyond which the level of comfort cannot be considered as good.. (Author)

  7. Assessment of an ultrasonic sensor and a capacitance probe for measurement of two-phase mixture level

    International Nuclear Information System (INIS)

    Kim, Chang Hyun; Lee, Dong Won; No, Hee Cheon

    2004-01-01

    We performed a comparison of two-phase mixture levels measured by an ultrasonic sensor and a two-wire type capacitance probe with visual data under the same experimental conditions. A series of experiments are performed with various combinations of airflow and initial water level using a test vessel with a height of 2m and an inner diameter of 0.3m. The ultrasonic sensor measured the two-phase mixture level with a maximum error of 1.77% with respect to the visual data. The capacitance probe severely under-predicted the level data in the high void fraction region. The cause of the error was identified as the change of the dielectric constant as the void fraction changes when the probe is applied to the measurement of the two-phase mixture levels. A correction method for the capacitance probe is proposed by correcting the change of the dielectric constant of the two-phase mixture. The correction method for the capacitance probe produces a r.m.s. error of 5.4%. The present experimental data are compared with the existing pool void fraction correlations based on drift-flux model. The Kataoka-Ishii correlation has the best agreement with the present experimental data with an r.m.s error of 2.5%

  8. Working level measurement of radon daughters and thoron daughters by personal dosimetry and continuous monitoring

    International Nuclear Information System (INIS)

    Phillips, C.R.; Leung, H.

    1981-01-01

    The performance of personal alpha dosimeters in mixed radon daughter and thoron daughter atmospheres in Ontario uranium mines is described together with monitoring developments which enable the radon daughter working level to be determined separately. The theoretical bases for continuous and integrated working level measurements based on individual and gross counts are presented in terms of the weighting factor for combining the thoron daughter working level with the radon daughter working level, and in terms of the in-growth time of the air. Implications for the determination of working level in the presence of thoron daughters are discussed

  9. Fracture toughness measurements on a glass bonded sodalite high-level waste form

    International Nuclear Information System (INIS)

    DiSanto, T.; Goff, K. M.; Johnson, S. G.; O'Holleran, T. P.

    1999-01-01

    The electrometallurgical treatment of metallic spent nuclear fuel produces two high-level waste streams; cladding hulls and chloride salt. Argonne National Laboratory is developing a glass bonded sodalite waste form to immobilize the salt waste stream. The waste form consists of 75 Vol.% crystalline sodalite (containing the salt) with 25 Vol.% of an ''intergranular'' glassy phase. Microindentation fracture toughness measurements were performed on representative samples of this material using a Vickers indenter. Palmqvist cracking was confirmed by post-indentation polishing of a test sample. Young's modulus was measured by an acoustic technique. Fracture toughness, microhardness, and Young's modulus values are reported, along with results from scanning electron microscopy studies

  10. Output, input and productivity measures at the industry level : The EU KLEMS Database

    NARCIS (Netherlands)

    O'Mahony, M.; Timmer, M.P.

    This article describes the contents and the construction of the EU KLEMS Growth and Productivity Accounts. This database contains industry-level measures of output, inputs and productivity for 25 European countries, Japan and the US for the period from 1970 onwards. The article considers the

  11. Clinical significance of measurement of plasma homocysteine (Hcy) levels in patients with hepatic cirrhosis

    International Nuclear Information System (INIS)

    Wu Jiaming

    2006-01-01

    Objective: To investigate the correlationship between the plasma homocysteine (Hcy) levels and development of hepatic cirrhosis as well as the diagnostic value of plasma Hcy determination. Method: Plasma Hcy levels were measured with ELISA in: (1) 64 patients with post-hepatitis cirrhosis (2) 42 patients with various types of hepatitis but no cirrhosis and (3) 60 controls. Results: The plasma levels of Hcy in patients with cirrhosis were significantly higher than those in the other two groups (P<0.01). The plasma Hcy levels in cirrhotic patients were well correlated with the levels of other hepatic fibrosis markers such as hyaluronic acid and laminin (r=0.87 and r=0.88 respectively, P<0.01), but were not correlated with cholesterol, triglyceride and HDL levels. Conclusion: Plasma Hcy levels was markedly elevated in cirrhotic patients and might be taken as a diagnostic marker. (authors)

  12. A computerized system to measure interproximal alveolar bone levels in epidemiologic, radiographic investigations. I

    International Nuclear Information System (INIS)

    Wouters, F.R.; Jon-And, C.; Frithiof, L.; Soeder, P.Oe.; Lavstedt, S.

    1988-01-01

    The aims of the study were to adapt a computerized system to epidemiologic conditions, for rapid full-mouth measurements of alveolar bone levels from X5-magnified periapical radiographs and to analyze the variations in measurement due to different system components. Full-mouth measurements of interproximal alveolar bone height in percentage of root and tooth lengths were completed within av average time of 15 min. per set of radiographs. An analysis of variance showed that the examiner variation in measurement of a linear scale distance was 0.02 mm. The measurement accuracy was different for different distances. Each distance (d) measured with this system should therefore be calibrated with the equation Y = -0.007 - 0.014 (log 3d - 1.50) where Y is the estimate of measurement accuracy. The present computerized system enabled rapid recordings and demonstrated good measurement precision and accuracy. These are valuable features in epidemiologic investigations

  13. Nitrosylated hemoglobin levels in human venous erythrocytes correlate with vascular endothelial function measured by digital reactive hyperemia.

    Directory of Open Access Journals (Sweden)

    Irina I Lobysheva

    Full Text Available Impaired nitric oxide (NO-dependent endothelial function is associated with the development of cardiovascular diseases. We hypothesized that erythrocyte levels of nitrosylated hemoglobin (HbNO-heme may reflect vascular endothelial function in vivo. We developed a modified subtraction method using Electron Paramagnetic Resonance (EPR spectroscopy to identify the 5-coordinate α-HbNO (HbNO concentration in human erythrocytes and examined its correlation with endothelial function assessed by peripheral arterial tonometry (PAT. Changes in digital pulse amplitude were measured by PAT during reactive hyperemia following brachial arterial occlusion in a group of healthy volunteers (50 subjects. Erythrocyte HbNO levels were measured at baseline and at the peak of hyperemia. We digitally subtracted an individual model EPR signal of erythrocyte free radicals from the whole EPR spectrum to unmask and quantitate the HbNO EPR signals.Mean erythrocyte HbNO concentration at baseline was 219+/-12 nmol/L (n = 50. HbNO levels and reactive hyperemia (RH indexes were higher in female (free of contraceptive pills than male subjects. We observed a dynamic increase of HbNO levels in erythrocytes isolated at 1-2 min of post-occlusion hyperemia (120+/-8% of basal levels; post-occlusion HbNO levels were correlated with basal levels. Both basal and post-occlusion HbNO levels were significantly correlated with reactive hyperemia (RH indexes (r = 0.58; P<0.0001 for basal HbNO.The study demonstrates quantitative measurements of 5-coordinate α-HbNO in human venous erythrocytes, its dynamic physiologic regulation and correlation with endothelial function measured by tonometry during hyperemia. This opens the way to further understanding of in vivo determinants of NO bioavailability in human circulation.

  14. Calculation of reasonable exemption levels for surface contamination by measuring overall gamma ray

    International Nuclear Information System (INIS)

    Ogino, Haruyuki; Hattori, Takatoshi

    2008-01-01

    The present regulation on surface contamination [Bq/cm 2 ] is determined from a simple radiological model for the most hazardous radionuclides (Pu-239 for alpha emitters and Sr-90 for beta emitters) and its extremely conservative model is applied for all other alpha and beta emitters. In this study, reasonable exemption levels for surface contamination are calculated for each radionuclide by adopting an original radiological dose evaluation method for surface contamination that can be applied in radiation safety, transport safety and waste safety. Furthermore, a new concept of judging the exemption by estimating the overall contamination [Bq] on the objects from the measurement of gamma ray has been designed and a reasonable value was derived. We conclude that the overall exemption levels obtained by gamma ray measurement can be one order smaller than those obtained by the conventional method for some radionuclides, such as Mn-54, Co-60, Nb-94, Cs-134, Cs-137, Eu-152 and Eu-154. (author)

  15. Validation of a method to measure plutonium levels in marine sediments in Cuba

    International Nuclear Information System (INIS)

    Sibello Hernández, Rita Y.; Cartas Aguila, Héctor A.; Cozzella, María Letizia

    2008-01-01

    The main objective of this research was to develop and to validate a method of radiochemical separation of plutonium, suitable from the economic and practical point of view, in Cuba conditions. This method allowed to determine plutonium activity levels in the marine sediments from Cienfuegos Bay. The selected method of radiochemical separation was that of anionic chromatography and the measure technique was the quadrupole inductively coupled plasma mass spectrometry. The method was applied to a certified reference material, six repetitions were carried out and a good correspondence between the average measured value and the average certified value of plutonium was achieved, so the trueness of the method was demonstrated. It was also proven the precision of the method, since it was obtained a variation coefficient of 11% at 95% confidence level. The obtained results show that the presence of plutonium in the analyzed marine sediment samples is only due to the global radioactive fallout. (author)

  16. Survey of radiofrequency radiation levels around GSM base stations and evaluation of measurement uncertainty

    Directory of Open Access Journals (Sweden)

    Vulević Branislav D.

    2011-01-01

    Full Text Available This paper is a summary of broadband measurement values of radiofrequency radiation around GSM base stations in the vicinity of residential areas in Belgrade and 12 other cities in Serbia. It will be useful for determining non-ionizing radiation exposure levels of the general public in the future. The purpose of this paper is also an appropriate representation of basic information on the evaluation of measurement uncertainty.

  17. Seasonal variation measurements of radon levels in caves using SSNTD method

    International Nuclear Information System (INIS)

    Espinosa, G.; Golzarri, J.I.; Gammage, R.B.; Sajo-Bohus, L.; Viccon-Pale, J.; Signoret-Poillon, M.

    2008-01-01

    The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm -3 , an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves

  18. Seasonal variation measurements of radon levels in caves using SSNTD method

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa, G. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Apartado Postal 20-364, 01000 Mexico, D.F. (Mexico)], E-mail: espinosa@fisica.unam.mx; Golzarri, J.I. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Apartado Postal 20-364, 01000 Mexico, D.F. (Mexico); Gammage, R.B. [Oak Ridge National Laboratory, PO Box 2008, Oak Ridge, TN 37831-6480 (United States); Sajo-Bohus, L. [Departamento de Fisica, Universidad Simon Bolivar (Venezuela); Viccon-Pale, J.; Signoret-Poillon, M. [El Hombre y su Ambiente, UAM-Xochimilco, Mexico D.F. (Mexico)

    2008-08-15

    The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

  19. Inversion of double-difference measurements from optical levelling for the Groningen gas field

    Directory of Open Access Journals (Sweden)

    P. A. Fokker

    2015-11-01

    Full Text Available Hydrocarbon extraction lead to compaction of the gas reservoir which is visible as subsidence on the surface. Subsidence measurements can therefore be used to better estimate reservoir parameters. Total subsidence is derived from the result of the measurement of height differences between optical benchmarks. The procedure from optical height difference measurements to absolute subsidence is an inversion, and the result is often used as an input for consequent inversions on the reservoir. We have used the difference measurements directly to invert for compaction of the Groningen gas reservoir in the Netherlands. We have used a linear inversion exercise to update an already existing reservoir compaction model of the field. This procedure yielded areas of increased and decreased levels of compaction compared to the existing compaction model in agreement with observed discrepancies in porosity and aquifer activity.

  20. Flow cytometric measurement of DNA level and steroid hormone receptor assay in breast cancer

    International Nuclear Information System (INIS)

    Zubrikhina, G.N.; Kuz'mina, Eh.V.; Bassalyk, L.S.; Murav'eva, N.I.

    1989-01-01

    DNA level measured by flow cytometry and estrogen and progesteron receptors assayed in tissue samples obtained from 85 malignant and 16 benign lesions of the breast. All the benign tumors revealed 2c DNA content and most of them were receptor-negative, while 74.1% of breast carcinomas displayed aneuploidy. Three patients (3.5%) had two lines of aneuploid cells. Many aneuploid tumors were receptor-negative. Preoperative radiation treatmet (14-20 Gy) did not significantly influence the level of steroid hormone receptors in tumors. Estrogen receptor level was higher in menopausal patients than in premenopausal ones

  1. Water level response measurement in a steel cylindrical liquid storage tank using image filter processing under seismic excitation

    Science.gov (United States)

    Kim, Sung-Wan; Choi, Hyoung-Suk; Park, Dong-Uk; Baek, Eun-Rim; Kim, Jae-Min

    2018-02-01

    Sloshing refers to the movement of fluid that occurs when the kinetic energy of various storage tanks containing fluid (e.g., excitation and vibration) is continuously applied to the fluid inside the tanks. As the movement induced by an external force gets closer to the resonance frequency of the fluid, the effect of sloshing increases, and this can lead to a serious problem with the structural stability of the system. Thus, it is important to accurately understand the physics of sloshing, and to effectively suppress and reduce the sloshing. Also, a method for the economical measurement of the water level response of a liquid storage tank is needed for the exact analysis of sloshing. In this study, a method using images was employed among the methods for measuring the water level response of a liquid storage tank, and the water level response was measured using an image filter processing algorithm for the reduction of the noise of the fluid induced by light, and for the sharpening of the structure installed at the liquid storage tank. A shaking table test was performed to verify the validity of the method of measuring the water level response of a liquid storage tank using images, and the result was analyzed and compared with the response measured using a water level gauge.

  2. Individual thermal comfort. Measurements versus perceived level; Thermisch individueel comfort. Metingen versus beleving

    Energy Technology Data Exchange (ETDEWEB)

    Noom, P.; Zeiler, W.; Boxem, G. [Unit Building Physics and Systems, Faculteit Bouwkunde, Technische Universiteit Eindhoven TUE, Eindhoven (Netherlands); Haan, J.F.B.C.; Van der Velden, J. [Kropman Installatietechniek, Rijswijk (Netherlands)

    2010-11-15

    In a normal office building measurements according to NEN-EN-ISO 7726 (Ergonomics of the thermal environment. Instruments for measuring physical quantities) have been carried out and a survey was held to determine the perceived thermal comfort of individuals. A comparison between the objective determined thermal comfort and the perceived thermal comfort shows quite a difference. This result was also reached in earlier research by others in laboratories. Therefore it is necessary to take care of the differences when designing a specific comfort level and try to determine the perceived comfort level of the individual occupants. [Dutch] Nieuwe optimalisatiemogelijkheden voor energiegebruik voor het comfort zijn mogelijk door vanuit de actuele en toekomstige individuele behoefte aan comfort van de gebruiker de installatie optimaal aan te sturen. Dit artikel geeft inzicht in de efficiente afstemming van vraag en aanbod van energie voor thermisch comfort. In een kantoorgebouw zijn metingen gedaan, conform NEN-EN-ISO 7726 (Ergonomics of the thermal environment. Instruments for measuring physical quantities), en er is een enquete gehouden om het thermisch comfort individueel te kunnen bepalen gedurende de werkdag. Het doel van de metingen was de verschillen tussen de individuele beleving en de werkelijke klimaat omstandigheden te kunnen bepalen.

  3. Community-Level Measures of Stroke Knowledge among Children: Findings from Hip Hop Stroke.

    Science.gov (United States)

    Simmons, Cailey; Noble, James M; Leighton-Herrmann, Ellyn; Hecht, Mindy F; Williams, Olajide

    2017-01-01

    Community-level determinants of stroke knowledge among children are unknown but could meaningfully impact public stroke education campaigns. We explored for associations between community- and school-level quality measures relative to baseline stroke knowledge among children participating in the Hip Hop Stroke program. Baseline stroke knowledge assessments were performed in 2839 fourth-, fifth-, and sixth-grade students (ages 9-11 years) from November 2005 to April 2014. Knowledge was assessed relative to school performance grade (SPG, graded A-F; a school-level measure determined by the New York City [NYC] Department of Education) and economic need index (ENI, range: 0-2; a community-level, within-school measure of subsidized housing and meals with higher scores indicating more socioeconomic distress). Schools studied included those with SPG = B (n = 196), SPG = C (n = 1590), and SPG = D (n = 1053) and mean ENI = .85 (standard deviation: .23). A composite assessment of knowledge, including 4 stroke symptoms (blurred vision, facial droop, sudden headache, and slurred speech), was conducted consistently since 2006. Overall, students correctly identified a mean of 1.74 stroke symptoms (95% confidence interval: 1.70-1.79; possible range: 0-4, expected value of chance response alone or no knowledge = 2). For quartiles of ENI, mean knowledge scores are as follows: ENI Q1  = 2.00, ENI Q2  = 2.09, ENI Q3  = 1.46, and ENI Q4  = 1.56 (ENI Q3 and ENI Q4 versus ENI Q1 , P < .001). For SPG, SPG = B schools: 2.09, SPG = C: 1.83, and SPG = D: 1.56 (SPG = C and SPG = D versus SPG = B schools, P ≤ .05). Children's stroke knowledge was lowest in NYC communities with greater economic need and lower school performance. These findings could guide stroke education campaign implementation strategies. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  4. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas

    Directory of Open Access Journals (Sweden)

    Makoto Onodera

    2016-01-01

    Full Text Available Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p=0.021, but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  5. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas.

    Science.gov (United States)

    Onodera, Makoto; Fujino, Yasuhisa; Kikuchi, Satoshi; Sato, Masayuki; Mori, Kiyofumi; Beppu, Takaaki; Inoue, Yoshihiro

    2016-01-01

    Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p = 0.021), but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  6. Study on on-Line Measurement and Controlling System of the Foundation Trench-Leveling Machine

    International Nuclear Information System (INIS)

    Yi, J G; Jiang, H Y; Xing, Y Z; Chen, J; Liu, J T

    2006-01-01

    Research the system software and hardware composing, the control mode, the online measurement and control principle based on the laser receiver and the inclination sensor as the signal source. After the laser receiver accepts the laser signal, the laser signal is carried through the light filter treatment so as to reduce the sunlight interference, and then amplified and modulated, last transmitted to the control unit. The inclination sensor adapts XWQJ02-01S, measure the slope angle the x and y verticality direction. The error adjusting range is ±0.05 0 . The separate time treatment avoids simultaneously adjusting the laser and inclination signal to each other interfere. The on-line measurement and control system realizes the parts to work on the plane that parallels with the datum plane of the laser beam scan. The trench-leveling machine must retain ±0.05 0 with the datum plane. Adapting the least square method to fit the linear curve, the movement trend of the work parts on the work plane is judged through the slope number. The test result shows that thought the combination measurement and control of the laser and slope angle the leveling precision are ±5mm/100. Its can satisfy with the construction criterion request

  7. Measurement sum theory and application - Application to low level measurements

    International Nuclear Information System (INIS)

    Puydarrieux, S.; Bruel, V.; Rivier, C.; Crozet, M.; Vivier, A.; Manificat, G.; Thaurel, B.; Mokili, M.; Philippot, B.; Bohaud, E.

    2015-09-01

    In laboratories, most of the Total Sum methods implemented today use substitution or censure methods for nonsignificant or negative values, and thus create biases which can sometimes be quite large. They are usually positive, and generate, for example, becquerel (Bq) counting or 'administrative' quantities of materials (= 'virtual'), thus artificially falsifying the records kept by the laboratories under regulatory requirements (environment release records, waste records, etc.). This document suggests a methodology which will enable the user to avoid such biases. It is based on the following two fundamental rules: - The Total Sum of measurement values must be established based on all the individual measurement values, even those considered non-significant including the negative values. Any modification of these values, under the pretext that they are not significant, will inevitably lead to biases in the accumulated result and falsify the evaluation of its uncertainty. - In Total Sum operations, the decision thresholds are arrived at in a similar way to the approach used for uncertainties. The document deals with four essential aspects of the notion of 'measurement Total Sums': - The expression of results and associated uncertainties close to Decision Thresholds, and Detection or Quantification Limits, - The Total Sum of these measurements: sum or mean, - The calculation of the uncertainties associated with the Total Sums, - Result presentation (particularly when preparing balance sheets or reports, etc.) Several case studies arising from different situations are used to illustrate the methodology: environmental monitoring reports, release reports, and chemical impurity Total Sums for the qualification of a finished product. The special case of material balances, in which the measurements are usually all significant and correlated (the covariance term cannot then be ignored) will be the subject of a future second document. This

  8. Use of commercial radon monitors for low level radon measurements in dynamically operated VOC emission test chambers

    International Nuclear Information System (INIS)

    Hofmann, M.; Richter, M.; Jann, O.

    2017-01-01

    Compared to the intended EU reference level of 300 Bq m -3 for indoor radon concentrations, the contribution of building materials appears to be low. Considering the recommended limit of 100 Bq m -3 by WHO, their contribution is supposed to be relevant, especially at low air exchange rates. This study as part of a two-part research project investigated the suitability of direct low level 222 Rn measurement under simulated indoor conditions with commercial radon monitors and dynamically operated emission test chambers. Active measuring devices based on ionisation or scintillation chambers with 1-σ uncertainties below 8.6% at 20 Bq m -3 were found to be best suitable for a practical test procedure for the determination of radon exhalation rates of building materials. For the measurement of such low concentrations, the knowledge of the accurate device background level is essential. (authors)

  9. A method of measurement of lifetimes of excited ion levels, using orientation transfer by Penning collisions

    International Nuclear Information System (INIS)

    Hamel, J.; Barrat, J.-P.

    1978-01-01

    A method for measuring the lifetimes of ionic excited levels is described. This method uses the transfer of coherence in a Penning collision using metastable optically oriented He 2 3 S 1 atoms. If R.F. transitions are induced in the (2 3 S 1 )He level, a transverse component of the magnetic moment of this level is created, which precesses coherently at the angular frequency ω of the R.F. field. The helium transverse orientation is partially transferred to the ions produced by Penning collisions. After the collision, the orientation transferred precesses around the external magnetic field at the Larmor frequency ω 0 ' of the ion excited level. The degree of orientation of the excited ion level depends, in the stationary state, on the average phase shift, during the lifetime tau prime of this level, between the Larmor precession at angular frequency ω 0 ' and the forced precession of helium (at angular frequency ω). The orientation of the ions is monitored by the modulation of the light emitted during their radiative decay. It is possible to determine the lifetime tau prime by measuring the degree of modulation of the reemitted light as a function of ω [fr

  10. Measurements of radon concentration levels in drinking water at urban area of Curitiba, Brazil

    International Nuclear Information System (INIS)

    Correa, Janine Nicolosi; Paschuk, Sergei A.; Schelin, Hugo R.; Barbosa, Laercio; Sadula, Tatyana; Matsuzaki, Cristiana A.

    2009-01-01

    Current work presents the results of more than 100 measurements of 222 Rn activity in drinking water collected at artesian bores at Curitiba region during the period of 2008 - 2009. The measurements were performed at the Laboratory of Applied Nuclear Physics of the Federal University of Technology in cooperation with the Nuclear Technology Development Center (CDTN) of Brazilian Nuclear Energy Committee (CNEN). Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specific kit of glass vessels Aqua KIT through the air pump. The equipment was adjusted with air flow of 0.5 L/min. The 222 Rn concentration levels were detected and analyzed by the computer every 10 minutes using the software DataEXPERT by GENITRON Instruments. Collected average levels of 222 Rn concentration were processed taking into account the volume of water sample and its temperature, atmospheric pressure and the total volume of the air in the vessels. Collected samples of water presented the average 222 Rn activity about 57.70 Bq/L which is almost 5 times more than maximum level of 11.1 Bq/L recommended by the USEPA (United States Environmental Protection Agency). It has to be noted that many artesian drillings presented the radon activity in the range of 100 - 200 Bq/L. Further measurements are planned to be performed at other regions of Parana State and will involve the mineral water sources, explored artesian drillings as well as soil samples. (author)''

  11. Measuring Confidence Levels of Male and Female Students in Open Access Enabling Courses

    Science.gov (United States)

    Atherton, Mirella

    2015-01-01

    The study of confidence was undertaken at the University of Newcastle with students selecting science courses at two campuses. The students were enrolled in open access programs and aimed to gain access to undergraduate studies in various disciplines at University. The "third person effect" was used to measure the confidence levels of…

  12. Validity of a New Kit Measuring Salivary Lactate Dehydrogenase Level for Screening Gingivitis.

    Science.gov (United States)

    Ekuni, Daisuke; Yamane-Takeuchi, Mayu; Kataoka, Kota; Yokoi, Aya; Taniguchi-Tabata, Ayano; Mizuno, Hirofumi; Miyai, Hisataka; Uchida, Yoko; Fukuhara, Daiki; Sugiura, Yoshio; Tomofuji, Takaaki; Morita, Manabu

    2017-01-01

    Aim . The aim of this study was to determine the usefulness of a new kit that can evaluate salivary lactate dehydrogenase (LD) level in real time for screening gingivitis. Materials and Methods . The study included 70 systemic healthy volunteers [29 males and 41 females; mean age ± SD: 24.1 ± 2.6 years]. Resting saliva was collected from each participant and LD level was evaluated in real time using the kit (a color-changing sheet with an integer scale ranging from 1 to 10). A dentist measured probing pocket depth, clinical attachment level, and the proportion of sites with bleeding on probing (% BOP) at six sites on all teeth. Gingivitis was diagnosed when the BOP value was ≥20%. Results . Salivary LD level was positively correlated with mean % BOP (odds ratio: 1.47, 95% confidence interval: 1.132-1.916, and P gingivitis in young adults, which contributes to early detection of future periodontitis.

  13. SHORT-TERM AND LONG-TERM WATER LEVEL PREDICTION AT ONE RIVER MEASUREMENT LOCATION

    Directory of Open Access Journals (Sweden)

    Rudolf Scitovski

    2012-12-01

    Full Text Available Global hydrological cycles mainly depend on climate changes whose occurrence is predominantly triggered by solar and terrestrial influence, and the knowledge of the high water regime is widely applied in hydrology. Regular monitoring and studying of river water level behavior is important from several perspectives. On the basis of the given data, by using modifications of general approaches known from literature, especially from investigation in hydrology, the problem of long- and short-term water level forecast at one river measurement location is considered in the paper. Long-term forecasting is considered as the problem of investigating the periodicity of water level behavior by using linear-trigonometric regression and short-term forecasting is based on the modification of the nearest neighbor method. The proposed methods are tested on data referring to the Drava River level by Donji Miholjac, Croatia, in the period between the beginning of 1900 and the end of 2012.

  14. Evaluation of bubbler/diaphragm techniques to measure surface level in the waste storage tanks

    International Nuclear Information System (INIS)

    Peters, T.J.; Hickman, B.J.; Colson, J.B.

    1993-10-01

    This report describes the results of tests conducted at the Pacific Northwest Laboratory (PNL) to determine if a bubbler technique can be used to determine the surface level in the waste tanks. Two techniques were evaluated. The first technique is a standard bubbler system in which a tube is placed below the surface of the liquid to be measured and air pressure inside a tube is increased until bubbles begin to become emitted from the tube. The air pressure then is a function of the pressure at the bottom of the tube. The second technique involves a system similar to the standard bubbler technique, but instead of bubbles being released into the material to be gauged, air pressure is increased against a diaphragm until enough pressure is applied to overcome the pressure of the liquid at the given depth, at which time the air then flows in a return loop back to a vent. The advantage of the diaphragm system is that it is a sealed system; thus no air is released into the waste tank materials, and it is not possible for the waste tank materials to get into the air flow. Based on the results of the tests conducted in this program, it appears that the bubbler and diaphragm systems that were tested could not be used for accurate measurements of the level in the waste tanks. Both exhibited deposits of simulated waste tank material at the end of the devices which affected the ability of the gauge to accurately determine changes in the surface level even though the measured value of the level was inaccurate. Further investigations into the cause of this inaccuracy may be warranted. Alternate diaphragm materials may improve the performance of this gauge

  15. Relationship between Corrosion Level of Rebar Embedded in Concrete, Corrosion Potential and Current Density Measured by Non-destructive Test Method

    International Nuclear Information System (INIS)

    Chung, Lan; Cho, Seung Ho; Roh, Young Sook; Kim, Joong Koo

    2004-01-01

    The purpose of this study is to identify corrosion mechanism and develop qualitative measurement method of corrosion level. Fist of all, structural behavior of each different level of corrosion states have been evaluated. And mathematical models that can predict corrosion level in terms of electric potential and corrosion intensity are proposed. Corrosion rate in reinforcing bar was investigated in this study using accelerated corrosion method due to electric potential differences based on Faradays law. Total 288 measurement spots were designed in terms of corrosion rates, diameter of reinforcing bars, and concrete cover thickness. Corrosion current densities and corrosion potentials of concrete were measured on these specimens using Gecor device. This study suggested the relationship between corrosion levels, and measured electric current density as follows

  16. Measurement of the heavy water level in the fuel channels of the RA reactor - Annex 11

    International Nuclear Information System (INIS)

    Nikolic, M.

    1964-01-01

    The objective of measuring the heavy water level in the reactor channels was to verify experimentally the possibilities of reactor cooling with parallel operation of heavy water pumps od 1500 rotations/min at nominal power of 6.5 MW. Measurements were done in 2 periphery and 2 central fuel channels with pumps speed 1500, 1800 and 3000 rotations/min by a contact probe with electric resistance measuring device. precision of the measurement was ±1 cm

  17. Clinical applications of measurement of serum immunoreactive levels of erythropoietin

    International Nuclear Information System (INIS)

    Miller, M.E.; Chandra, M.; Garcia, J.F.

    1985-01-01

    The purification of erythropoietin (Ep) in 1977 enabled investigators to more clearly define the role of this hormone in erythropoiesis in man. Radioimmunoassays were rapidly developed. Undoubtedly differences between levels of immunoreactive and biologically active Ep will be found but the resolution of these discrepancies will expand our understanding of the erythron. Recently others described a monoclonal antibody against Ep. Because of this breakthrough, large quantities of pure hormone should soon be available to a larger number of investigators than currently have access to it. The major clinical use of this hormone will probably be in the treatment of the anemia of chronic renal disease. In the relatively few years since the radioimmunoassay (RIA) was developed, measurements of the levels of this hormone have been made in several disease states as well as in normal man. Most of the findings to date confirm the predictions that have been made over the years based on studies done using the rather crude bioassay for Ep. In the present study the authors shall review and expand on what is known about subjects with chronic lung and renal disease

  18. Dual Mode NOx Sensor: Measuring Both the Accumulated Amount and Instantaneous Level at Low Concentrations

    Directory of Open Access Journals (Sweden)

    Jaco H. Visser

    2012-03-01

    Full Text Available The accumulating-type (or integrating-type NOx sensor principle offers two operation modes to measure low levels of NOx: The direct signal gives the total amount dosed over a time interval and its derivative the instantaneous concentration. With a linear sensor response, no baseline drift, and both response times and recovery times in the range of the gas exchange time of the test bench (5 to 7 s, the integrating sensor is well suited to reliably detect low levels of NOx. Experimental results are presented demonstrating the sensor’s integrating properties for the total amount detection and its sensitivity to both NO and to NO2. We also show the correlation between the derivative of the sensor signal and the known gas concentration. The long-term detection of NOx in the sub-ppm range (e.g., for air quality measurements is discussed. Additionally, a self-adaption of the measurement range taking advantage of the temperature dependency of the sensitivity is addressed.

  19. Measurement and calculation of excitation cross sections and level ionization by electron impact

    International Nuclear Information System (INIS)

    Blanco Rames, F.

    1990-01-01

    The experimental and theoretical study of the atomic structure in neutral noble gases is studied in this work. It mainly deals with the determination of total cross sections by electron impact and transition probabilities, including: Chapter 1: Theoretical introduction and the intermediate coupling description obtained for 420 levels of s, p and d configurations in neutral noble gases. Chapter 2: Experimental and theoretical values for electron collision cross sections are obtained for several levels of He, Ne, Ar and Kr. Our results as well as those available from existing bibliography are sumarized and compared. By means of an intermediate coupling treatment a number of regularities is found that provides us with some useful approximate semi empirical expressions. Chapter 3: Determination of lifetime and transition probabilities. Lifetime measurements are carried out by means of laser excitation and multichannel delayed coincidences technique. The experimental setup and electronics are also described. Chapter 4: Details the experimental setup developed for electron cross sections measurement by the optical method. The difficulties of this method and their treatment are also shown. (Author)

  20. The Betrayal Aversion Elicitation Task: An Individual Level Betrayal Aversion Measure.

    Science.gov (United States)

    Aimone, Jason; Ball, Sheryl; King-Casas, Brooks

    2015-01-01

    Research on betrayal aversion shows that individuals' response to risk depends not only on probabilities and payoffs, but also on whether the risk includes a betrayal of trust. While previous studies focus on measuring aggregate levels of betrayal aversion, the connection between an individual's own betrayal aversion and other individually varying factors, including risk preferences, are currently unexplored. This paper develops a new task to elicit an individual's level of betrayal aversion that can then be compared to individual characteristics. We demonstrate the feasibility of our new task and show that our aggregate individual results are consistent with previous studies. We then use this classification to ask whether betrayal aversion is correlated with risk aversion. While we find risk aversion and betrayal aversion have no significant relationship, we do observe that risk aversion is correlated with non-social risk preferences, but not the social, betrayal related, risk component of the new task.

  1. Specific calibration problems for gammaspectrometric measurements of low-level radioactivity in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, D [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Wershofen, H [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)

    1997-03-01

    Gammaspectrometric measurements of low-level radioactivity in environmental samples are always done in a close source detector geometry. This geometry causes coincidence-summing effects for measurements of multi-photon emitting nuclides. The measurements of radioactivity in environmental samples are also influenced by the absorption of photons in the materials which have to be analysed. Both effects must be taken into account by correction factors with respect to an energy-specific calibration of the detector system for a given geometry and a given composition of the calibration source. The importance of these corrections is emphasized. It is the aim of the present paper to compare different experimental and theoretical methods for the determination of these correction factors published by various authors and to report about efforts to refine them. (orig.)

  2. A new proxy measure for state-level gun ownership in studies of firearm injury prevention.

    Science.gov (United States)

    Siegel, Michael; Ross, Craig S; King, Charles

    2014-06-01

    Since many states are considering gun control laws, researchers need reliable data on rates of gun ownership at the state level. Survey measures of gun ownership in all 50 states, however, are only available for 3 years, and no state-level data have been collected since 2004. Consequently, the National Research Council has declared the development of a valid proxy that can be constructed from accessible, annual, state-level data to be a priority. While such a proxy does exist (the proportion of suicides in a state committed using a gun (FS/S), its correlation with state estimates of gun ownership in recent years is only 0.80. Using state-level data for the years 2001, 2002 and 2004, we developed an improved proxy for state-level gun ownership that uses FS/S (firearm suicides divided by all suicides) and also the per capita number of hunting licenses. We validated this measure using data from surveys of gun ownership conducted in 48 states during 1996 and 1999, and in 21 states during 1995-1998. Adding per capita hunting licenses to the proxy increased its correlation with survey-measured gun ownership from 0.80 to 0.95. The correlations of the new proxy with gun ownership in the two validation studies were 0.95 and 0.97. We conclude that the combination of FS/S and per capita hunting licenses improves substantially upon FS/S alone. This new proxy is easily computed from data that are available annually by state and may be useful for investigating the effect of gun prevalence on firearm-related morbidity and mortality. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Test Plan for Measuring Ventilation Rates and Combustible Gas Levels in TWRS Active Catch Tanks

    Energy Technology Data Exchange (ETDEWEB)

    NGUYEN, D.M.

    1999-10-25

    The purpose of this sampling activity is to obtain data to support an initial evaluation of potential hazards due to the presence of combustible gas in catch tanks that are currently operated by the River Protection Project (RPP). Results of the hazard analysis will be used to support closure of the flammable gas unreviewed safety question for these facilities. The data collection will be conducted in accordance with the Tank Safety Screening Data Quality Objective (Dukelow et al. 1995). Combustible gas, ammonia, and organic vapor levels in the headspace of the catch tanks will be field-measured using hand-held instruments. If a combustible gas level measurement in a tank exceeds an established threshold, gas samples will he collected in SUMMA' canisters for more extensive laboratory analysis. In addition, ventilation rates of some catch tanks will be measured to evaluate removal of flammable gas by air flowing through the tanks. This test plan identifies the sample collection, laboratory analysis, quality assurance, and reporting objectives for this data collection effort. The plan also provides the procedures for field measurement of combustible gas concentrations and ventilation rates.

  4. Measurement of seminal fluid 5 α dihydrotestosterone levels during investigations of sterility

    International Nuclear Information System (INIS)

    Massart, C.; Le Lannou, D.; Savoure, M.; Allannic, H.; Nicol, M.

    1981-01-01

    Two androgens (testosterone, 5 α dihydrotestosterone) were measured by radioimmunoassay in the seminal liquid. A statistic comparison of the results has been applied to samples taken from sterile men and classed chiefly according to sperm count. Different groups were explored: normospermia; oligospermia; various azoospermias. No significant differences testosterone were found between the groups. Levels of DHT are lower in oligospermia, and such more in azoospermia. The signification of the results is discussed [fr

  5. Measurement of serum leptin levels in polycystic ovary syndrome with hyperandrogenemia and its significance

    International Nuclear Information System (INIS)

    Wang Yande; Zhang Zhiping; Lu Gen; Luo Beilei

    2002-01-01

    Objective: To investigate the serum leptin concentration in polycystic ovary syndrome (PCOS) with hyperandrogenemia (HA) and its relationship with testosterone (T) level and body mass index (BMI). Methods: Serum leptin levels were measured by radioimmunoassay in 53 patients with PCOS, in which 36 cases were of the in non-obesity group and 17 cases in obese group. 30 non-obese cases and 20 obese cases without PCOS served as controls. Results: The levels of leptin in PCOS with HA in obese and non-obese group were significantly higher than those in control group (all p < 0.01). There was a positive correlation between serum leptin levels and testosterone levels in both groups (r = 0.51, p < 0.01 and r = 0.58, p < 0.01). No correlation existed between serum leptin levels and body mass index (BMI) in PCOS patients of non-obese group but there was positive correlation in obesity group (r = 0.56, p < 0.01). Conclusion: High serum leptin levels is one of the characteristic in PCOS patients. The HA in PCOS patients is related to serum leptin levels and heavyweight or obese patients have the phenomenon of leptin resistance

  6. Cost calculation and financial measures for high-level waste disposal business

    International Nuclear Information System (INIS)

    Sekiguchi, Hiromasa.

    1987-01-01

    A study is made on the costs for disposal of high-level wastes, centering on financial problems involving cost calculation for disposal business and methods and systems for funding the business. The first half of the report is focused on calculation of costs for disposal business. Basic equations are shown to calculate the total costs required for a disposal plant and the costs for disposal of one unit of high-level wastes. A model is proposed to calculate the charges to be paid by electric power companies to the plant for disposal of their wastes. Another equation is derived to calculate the disposal charge per kWh of power generation in a power plant. The second half of the report is focused on financial measures concerning expenses for disposal. A financial basis should be established for the implementation of high-level waste disposal. It is insisted that a reasonable method for estimating the disposal costs should be set up and it should be decided who will pay the expenses. Discussions are made on some methods and systems for funding the disposal business. An additional charge should be included in the electricity bill to be paid by electric power users, or it should be included in tax. (Nogami, K.)

  7. Test plan for measuring ventilation rates and combustible gas levels in TWRS active catch tanks

    Energy Technology Data Exchange (ETDEWEB)

    NGUYEN, D.M.

    1999-05-20

    The purpose of this test is to provide an initial screening of combustible gas concentrations in catch tanks that currently are operated by Tank Waste Remediation System (TWRS). The data will be used to determine whether or not additional data will be needed for closure of the flammable gas unreviewed safety question for these facilities. This test will involve field measurements of ammonia, organic vapor, and total combustible gas levels in the headspace of the catch tanks. If combustible gas level in a tank exceeds an established threshold, gas samples will be collected in SUMMA canisters for more extensive laboratory analysis. In addition, ventilation rates of some catch tanks will be measured to evaluate removal of flammable gas by air flow through the tanks.

  8. Test plan for measuring ventilation rates and combustible gas levels in RPP active catch tanks

    Energy Technology Data Exchange (ETDEWEB)

    NGUYEN, D.M.

    1999-06-03

    The purpose of this test is to provide an initial screening of combustible gas concentrations in catch tanks that currently are operated by River Protection Project (RPP). The data will be used to determine whether or not additional data will be needed for closure of the flammable gas unreviewed safety question for these facilities. This test will involve field measurements of ammonia, organic vapor, and total combustible gas levels in the headspace of the catch tanks. If combustible gas level in a tank exceeds an established threshold, gas samples will be collected in SUMMA canisters for more extensive laboratory analysis. In addition, ventilation rates of some catch tanks will be measured to evaluate removal of flammable gas by air flow through the tanks.

  9. The Impact of Partial Measurement Invariance on Testing Moderation for Single and Multi-Level Data.

    Science.gov (United States)

    Hsiao, Yu-Yu; Lai, Mark H C

    2018-01-01

    Moderation effect is a commonly used concept in the field of social and behavioral science. Several studies regarding the implication of moderation effects have been done; however, little is known about how partial measurement invariance influences the properties of tests for moderation effects when categorical moderators were used. Additionally, whether the impact is the same across single and multilevel data is still unknown. Hence, the purpose of the present study is twofold: (a) To investigate the performance of the moderation test in single-level studies when measurement invariance does not hold; (b) To examine whether unique features of multilevel data, such as intraclass correlation (ICC) and number of clusters, influence the effect of measurement non-invariance on the performance of tests for moderation. Simulation results indicated that falsely assuming measurement invariance lead to biased estimates, inflated Type I error rates, and more gain or more loss in power (depends on simulation conditions) for the test of moderation effects. Such patterns were more salient as sample size and the number of non-invariant items increase for both single- and multi-level data. With multilevel data, the cluster size seemed to have a larger impact than the number of clusters when falsely assuming measurement invariance in the moderation estimation. ICC was trivially related to the moderation estimates. Overall, when testing moderation effects with categorical moderators, employing a model that accounts for the measurement (non)invariance structure of the predictor and/or the outcome is recommended.

  10. The Impact of Partial Measurement Invariance on Testing Moderation for Single and Multi-Level Data

    Directory of Open Access Journals (Sweden)

    Yu-Yu Hsiao

    2018-05-01

    Full Text Available Moderation effect is a commonly used concept in the field of social and behavioral science. Several studies regarding the implication of moderation effects have been done; however, little is known about how partial measurement invariance influences the properties of tests for moderation effects when categorical moderators were used. Additionally, whether the impact is the same across single and multilevel data is still unknown. Hence, the purpose of the present study is twofold: (a To investigate the performance of the moderation test in single-level studies when measurement invariance does not hold; (b To examine whether unique features of multilevel data, such as intraclass correlation (ICC and number of clusters, influence the effect of measurement non-invariance on the performance of tests for moderation. Simulation results indicated that falsely assuming measurement invariance lead to biased estimates, inflated Type I error rates, and more gain or more loss in power (depends on simulation conditions for the test of moderation effects. Such patterns were more salient as sample size and the number of non-invariant items increase for both single- and multi-level data. With multilevel data, the cluster size seemed to have a larger impact than the number of clusters when falsely assuming measurement invariance in the moderation estimation. ICC was trivially related to the moderation estimates. Overall, when testing moderation effects with categorical moderators, employing a model that accounts for the measurement (noninvariance structure of the predictor and/or the outcome is recommended.

  11. Using satellite observations in performance evaluation for regulatory air quality modeling: Comparison with ground-level measurements

    Science.gov (United States)

    Odman, M. T.; Hu, Y.; Russell, A.; Chai, T.; Lee, P.; Shankar, U.; Boylan, J.

    2012-12-01

    Regulatory air quality modeling, such as State Implementation Plan (SIP) modeling, requires that model performance meets recommended criteria in the base-year simulations using period-specific, estimated emissions. The goal of the performance evaluation is to assure that the base-year modeling accurately captures the observed chemical reality of the lower troposphere. Any significant deficiencies found in the performance evaluation must be corrected before any base-case (with typical emissions) and future-year modeling is conducted. Corrections are usually made to model inputs such as emission-rate estimates or meteorology and/or to the air quality model itself, in modules that describe specific processes. Use of ground-level measurements that follow approved protocols is recommended for evaluating model performance. However, ground-level monitoring networks are spatially sparse, especially for particulate matter. Satellite retrievals of atmospheric chemical properties such as aerosol optical depth (AOD) provide spatial coverage that can compensate for the sparseness of ground-level measurements. Satellite retrievals can also help diagnose potential model or data problems in the upper troposphere. It is possible to achieve good model performance near the ground, but have, for example, erroneous sources or sinks in the upper troposphere that may result in misleading and unrealistic responses to emission reductions. Despite these advantages, satellite retrievals are rarely used in model performance evaluation, especially for regulatory modeling purposes, due to the high uncertainty in retrievals associated with various contaminations, for example by clouds. In this study, 2007 was selected as the base year for SIP modeling in the southeastern U.S. Performance of the Community Multiscale Air Quality (CMAQ) model, at a 12-km horizontal resolution, for this annual simulation is evaluated using both recommended ground-level measurements and non-traditional satellite

  12. The effect of base image window level selection on the dimensional measurement accuracy of resultant three-dimensional image displays

    International Nuclear Information System (INIS)

    Kurmis, A.P.; Hearn, T.C.; Reynolds, K.J.

    2003-01-01

    Purpose: The aim of this study was to determine the effect of base image window level selection on direct linear measurement of knee structures displayed using new magnetic resonance (MR)-based three-dimensional reconstructed computer imaging techniques. Methods: A prospective comparative study was performed using a series of three-dimensional knee images, generated from conventional MR imaging (MRI) sections. Thirty distinct anatomical structural features were identified within the image series of which repeated measurements were compared at 10 different window grey scale levels. Results: Statistical analysis demonstrated an excellent raw correlation between measurements and suggested no significant difference between measurements made at each of the 10 window level settings (P>0.05). Conclusions: The findings of this study suggest that unlike conventional MR or CT applications, grey scale window level selection at the time of imaging does not significantly affect the visual quality of resultant three-dimensional reconstructed images and hence the accuracy of subsequent direct linear measurement. The diagnostic potential of clinical progression from routine two-dimensional to advanced three-dimensional reconstructed imaging techniques may therefore be less likely to be degraded by inappropriate MR technician image windowing during the capturing of image series

  13. Measurement of blood calprotectin (MRP-8/MRP-14) levels in patients with juvenile idiopathic arthritis.

    Science.gov (United States)

    Bojko, Jaryna

    2017-01-01

    The aim of the investigation was to compare blood calprotectin (MRP8/14, S100A 8/9) levels in patients with systemic-onset, polyarticular, RF-negative and oligoarticular subtypes of juvenile idiopathic arthritis (JIA), and to explore links between blood calprotectin levels and clinical and laboratory markers of JIA activity. Measurement of calprotectin in blood serum was performed in 160 patients with JIA followed up at Lviv Regional Council Public Institution "Western-Ukrainian Specialised Children's Medical Centre". Seventeen patients with systemic-onset JIA (sJIA) and 49 patients with other JIA subtypes (RF-negative polyarthritis and oligoarthritis) in the active phase of the disease were included in this study. Determination of calprotectin levels in blood serum was performed using EK-MRP8/14 Buhlmann Calprotectin reagents (Buhlmann, Switzerland) by the ELISA method. The results of the investigations showed that blood calprotectin levels were higher in patients with systemic-onset subtype of the disease (median 13,800 ng/ml), and differed significantly from levels in healthy children (median 1,800 ng/ml, p = 0.00002), levels in patients with articular subtypes of JIA (median 2,700 ng/ml, p = 0.000008), and patients with RF-negative polyarthritis (median 3,800 ng/ml, p = 0.003226) and oligoarthritis (median 2,500 ng/ml, p = 0.000009). The highest blood calprotectin levels were found in patients with newly diagnosed sJIA, the median being 32,500 ng/ml (range: 13,800-177,000 ng/ml). Direct correlations were found between blood calprotectin and JADAS 27 activity score ( p = 0.000009), ESR ( p = 0.000079) and CRP ( p = 0.000058). Blood calprotectin level is one of the measures that can be used to confirm the diagnosis of sJIA and to monitor the disease activity and therapy effectiveness.

  14. Measurement of anti-Ascaris IgE antibody levels in tropical allergic patients, using modified ELISA.

    Science.gov (United States)

    Lynch, N R; Pérez, M; López, R I; Turner, K J

    1987-01-01

    The two most common situations in which the determination of serum immunoglobulin E (IgE) levels is of interest are allergic disease and helminthic infection. This is of particular importance in the tropical environment, as helminthiasis possibly influences the expression of allergic reactivity. Because of the low absolute serum levels of IgE, solid-phase radioimmunoassay (RIA) is conventionally used for its measurement. The radioactive and toxic volatile reagents required restricted application of such assays in the tropical situation. We evaluated a nitrocellulose-based, avidin biotin-amplified enzyme-linked immunosorbent assay (ELISA) for IgE, in which monoclonal anti-IgE antibodies were employed. Excellent correlations were obtained between ELISA and RIA for both total and allergen-specific IgE measurement. The ELISA was then applied to determine the levels of anti-Ascaris antibodies in selected allergic patients, in whom no cutaneous immediate hypersensitivity reactions were demonstrated against common environmental allergens such as house dust, but who had positive skin reactions to Ascaris extract. When compared with non-allergic subjects who had equivalent cutaneous reactivity, no significant differences were found in total IgE levels, house-dust specific IgE levels or non-reaginic anti-Ascaris antibody levels. However, higher levels of IgE antibody against the parasite were detected in the allergic subjects. This observation raises the question of the possible role of Ascaris infection in the stimulation of allergic reactions in such patients. We describe an immunoenzymatic assay for total and specific IgE antibody that is better adapted to the tropical situation than the commonly used radioimmunoassays.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Background noise levels measured in the NASA Lewis 9- by 15-foot low-speed wind tunnel

    Science.gov (United States)

    Woodward, Richard P.; Dittmar, James H.; Hall, David G.; Kee-Bowling, Bonnie

    1994-01-01

    The acoustic capability of the NASA Lewis 9 by 15 Foot Low Speed Wind Tunnel has been significantly improved by reducing the background noise levels measured by in-flow microphones. This was accomplished by incorporating streamlined microphone holders having a profile developed by researchers at the NASA Ames Research Center. These new holders were fabricated for fixed mounting on the tunnel wall and for an axially traversing microphone probe which was mounted to the tunnel floor. Measured in-flow noise levels in the tunnel test section were reduced by about 10 dB with the new microphone holders compared with those measured with the older, less refined microphone holders. Wake interference patterns between fixed wall microphones were measured and resulted in preferred placement patterns for these microphones to minimize these effects. Acoustic data from a model turbofan operating in the tunnel test section showed that results for the fixed and translating microphones were equivalent for common azimuthal angles, suggesting that the translating microphone probe, with its significantly greater angular resolution, is preferred for sideline noise measurements. Fixed microphones can provide a local check on the traversing microphone data quality, and record acoustic performance at other azimuthal angles.

  16. Level Lifetime Measurements in ^150Sm

    Science.gov (United States)

    Barton, C. J.; Krücken, R.; Beausang, C. W.; Caprio, M. A.; Casten, R. F.; Cooper, J. R.; Hecht, A. A.; Newman, H.; Novak, J. R.; Pietralla, N.; Wolf, A.; Zyromski, K. E.; Zamfir, N. V.; Börner, H. G.

    2000-10-01

    Shape/phase coexistence and the evolution of structure in the region around ^152Sm have recently been of great interest. Experiments performed at WNSL, Yale University, measured the lifetime of low spin states in a target of ^150Sm with the recoil distance method (RDM) and the Doppler-shift attenuation method (DSAM). The low spin states, both yrast and non-yrast, were populated via Coulomb excitation with a beam of ^16O. The experiments were performed with the NYPD plunger in conjunction with the SPEEDY γ-ray array. The SCARY array of solar cells was used to detect backward scattered projectiles, selecting forward flying Coulomb excited target nuclei. The measured lifetimes yield, for example, B(E2) values for transitions such as the 2^+2 arrow 2^+1 and the 2^+3 arrow 0^+_1. Data from the RDM measurment and the DSAM experiment will be presented. This work was supported by the US DOE under grants DE-FG02-91ER-40609 and DE-FG02-88ER-40417.

  17. Variability in and agreement between modeled and personal continuously measured black carbon levels using novel smartphone and sensor technologies.

    Science.gov (United States)

    Nieuwenhuijsen, Mark J; Donaire-Gonzalez, David; Rivas, Ioar; de Castro, Montserrat; Cirach, Marta; Hoek, Gerard; Seto, Edmund; Jerrett, Michael; Sunyer, Jordi

    2015-03-03

    Novel technologies, such as smartphones and small personal continuous air pollution sensors, can now facilitate better personal estimates of air pollution in relation to location. Such information can provide us with a better understanding about whether and how personal exposures relate to residential air pollution estimates, which are normally used in epidemiological studies. The aims of this study were to examine (1) the variability in personal air pollution levels during the day and (2) the relationship between modeled home and school estimates and continuously measured personal air pollution exposure levels in different microenvironments (e.g., home, school, and commute). We focused on black carbon as an indicator of traffic-related air pollution. We recruited 54 school children (aged 7-11) from 29 different schools around Barcelona as part of the BREATHE study, an epidemiological study of the relation between air pollution and brain development. For 2 typical week days during 2012-2013, the children were given a smartphone with CalFit software to obtain information on their location and physical activity level and a small sensor, the micro-aethalometer model AE51, to measure their black carbon levels simultaneously and continuously. We estimated their home and school exposure to PM2.5 filter absorbance, which is well-correlated with black carbon, using a temporally adjusted PM2.5 absorbance land use regression (LUR) model. We found considerable variation in the black carbon levels during the day, with the highest levels measured during commuting periods (geometric mean = 2.8 μg/m(3)) and the lowest levels at home (geometric mean = 1.3 μg/m(3)). Hourly temporally adjusted LUR model estimates for the home and school showed moderate to good correlation with measured personal black carbon levels at home and school (r = 0.59 and 0.68, respectively) and lower correlation with commuting trips (r = 0.32 and 0.21, respectively). The correlation between modeled home

  18. Is Grey Level a Suitable Alternative to Low-Contrast Penetration as a Serial Measure of Sensitivity in Computerised Ultrasound Quality Assurance?

    Science.gov (United States)

    Dudley, Nicholas J; Gibson, Nicholas M

    2017-02-01

    The aim of this study was to test the hypothesis that grey levels are a suitable alternative measure of sensitivity in ultrasound imaging quality assurance, as there are several caveats in the use of penetration depth. In a primary cohort of nine probes, where measurements had been made for 6 to 34 mo, both penetration depth and mean grey level fell below tolerance for six probes; both penetration depth and mean grey level remained within tolerance for three probes. In a secondary cohort where a measurement programme had been in place for a shorter period, grey level and/or penetration depth fell below tolerance in 15 of 66 probes; the sensitivity and specificity of at least 10% loss of grey level in predicting >5% loss in penetration depth were 91% and 93%, respectively. A loss of grey level accompanies a loss of penetration and provides a suitable alternative measure of sensitivity. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  19. Measuring the level and content of consciousness during epileptic seizures: the Ictal Consciousness Inventory.

    Science.gov (United States)

    Cavanna, A E; Mula, M; Servo, S; Strigaro, G; Tota, G; Barbagli, D; Collimedaglia, L; Viana, M; Cantello, R; Monaco, F

    2008-07-01

    Ictal alterations of the level of general awareness and subjective content of consciousness play a pivotal role in the clinical phenomenology of epilepsy, and reflect the pathological involvement of different neurobiological substrates. However, no self-reported measures have been proposed for patients experiencing altered conscious states during seizures. This study describes the development and validation of a new scale for the quantitative assessment of the level and content of ictal consciousness, the Ictal Consciousness Inventory (ICI). The ICI is a 20-item questionnaire generated on the basis of interviews with patients, literature review, and consultation with experts. It was tested on a sample of 110 patients attending three different epilepsy clinics in Northern Italy, who also completed standardized clinical scales. Standard psychometric methods were used to demonstrate that this scale satisfies criteria for acceptability, reliability, and validity. The ICI is proposed as a user-friendly and clinically sound instrument for the measurement of ictal alterations of consciousness in patients with epilepsy.

  20. Proceedings of the international symposium on safety related measurements in PWRs: Topic of the first meeting: 'Temperature and level measurements'

    International Nuclear Information System (INIS)

    2001-09-01

    Numerous teams of experts from several countries deal with theme of measurement important for safety operation of WWER reactors. These special teams have a need to meet at various opportunities to change their experience. As an example I can mention meeting of experts from Russia , Germany, France and Slovakia at completion and reconstruction of Slovak NPP, at modernisation of Russian and Bulgarian NPP. Mentioned meetings have invoked an idea of participants to organise a common action aimed at measurement important for safety operation of WWER, that participants can change their experience from mentioned area at welcome environment of symposium. Therefore, at meeting of experts from Siemens, INCOR and VUJE at the end of the year 2000 participants agreed on realisation of such common action. Participants have taken orientation at all safety measurements for very deep topic. Therefore, they have decided in respect of this first meeting of symposium to give consideration to only some special measurements in particular to temperature and surface. In case of interest there is possible to take focus at other type of measurements. Slovakia has been chosen for the first meeting place on basis of economic reasons and also because a number of improvements of standard reactor temperature measuring procedures have been implemented here that over passed its frontiers. In addition the first fail-safe level measuring in reactor pressure vessel has been effectuated in Slovakia

  1. Background compensated GM counter for the measurement of low level #betta#-activity

    International Nuclear Information System (INIS)

    Mori, C.; Kumanomido, H.; Watanabe, T.

    1983-01-01

    When low level activity of a #betta#-ray source or surface contamination is to be measured with a GM counter, it is desirable to obtain a net count without background count through a single measurement. An end-window GM counter for such a purpose was constructed. The counter has a diaphragm to divide it into two parts. The front part, the window side, can detect #betta#-rays and background radiations, while the rear part only detects background, since #betta#-rays coming through the front are absorbed by the diaphragm. In the counter type I, the sensitive volumes of the two parts are the same and the anode wire of the front is connected to that of the rear through an electric resistor which leads to yielding different pulse heights and rise times. The net count of #betta#-rays can be obtained through a single measurement by subtracting the count in the rear part from that in the front part. In the counter type II, the lengths of the anode wires of the two parts are different, which gives rise to different pulse heights. With a background compensated GM counter, it is possible to shorten the measuring time, keeping nearly the same accuracy compared with a conventional GM counter. (orig.)

  2. Personality traits in old age: measurement and rank-order stability and some mean-level change.

    Science.gov (United States)

    Mõttus, René; Johnson, Wendy; Deary, Ian J

    2012-03-01

    Lothian Birth Cohorts, 1936 and 1921 were used to study the longitudinal comparability of Five-Factor Model (McCrae & John, 1992) personality traits from ages 69 to 72 years and from ages 81 to 87 years, and cross-cohort comparability between ages 69 and 81 years. Personality was measured using the 50-item International Personality Item Pool (Goldberg, 1999). Satisfactory measurement invariance was established across time and cohorts. High rank-order stability was observed in both cohorts. Almost no mean-level change was observed in the younger cohort, whereas Extraversion, Agreeableness, Conscientiousness, and Intellect declined significantly in the older cohort. The older cohort scored higher on Agreeableness and Conscientiousness. In these cohorts, individual differences in personality traits continued to be stable even in very old age, mean-level changes accelerated.

  3. Evaluating fundamentals of care: The development of a unit-level quality measurement and improvement programme.

    Science.gov (United States)

    Parr, Jenny M; Bell, Jeanette; Koziol-McLain, Jane

    2018-06-01

    The project aimed to develop a unit-level quality measurement and improvement programme using evidence-based fundamentals of care. Feedback from patients, families, whānau, staff and audit data in 2014 indicated variability in the delivery of fundamental aspects of care such as monitoring, nutrition, pain management and environmental cleanliness at a New Zealand District Health Board. A general inductive approach was used to explore the fundamentals of care and design a measurement and improvement programme, the Patient and Whānau Centred Care Standards (PWCCS), focused on fundamental care. Five phases were used to explore the evidence, and design and test a measurement and improvement framework. Nine identified fundamental elements of care were used to define expected standards of care and develop and test a measurement and improvement framework. Four six-monthly peer reviews have been undertaken since June 2015. Charge Nurse Managers used results to identify quality improvements. Significant improvement was demonstrated overall, in six of the 27 units, in seven of the nine standards and three of the four measures. In all, 89% (n = 24) of units improved their overall result. The PWCCS measurement and improvement framework make visible nursing fundamentals of care in line with continuous quality improvement to increase quality of care. Delivering fundamentals of care is described by nurses as getting ?back to basics'. Patient and family feedback supports the centrality of fundamentals of care to their hospital experience. Implementing a unit-level fundamentals of care quality measurement and improvement programme clarifies expected standards of care, highlights the contribution of fundamentals of care to quality and provides a mechanism for ongoing improvements. © 2018 John Wiley & Sons Ltd.

  4. Effect of radiation dose level on accuracy and precision of manual size measurements in chest tomosynthesis evaluated using simulated pulmonary nodules

    International Nuclear Information System (INIS)

    Soederman, Christina; Allansdotter Johnsson, Aase; Vikgren, Jenny; Rossi Norrlund, Rauni; Molnar, David; Svalkvist, Angelica; Maansson, Lars Gunnar; Baath, Magnus

    2016-01-01

    The aim of the present study was to investigate the dependency of the accuracy and precision of nodule diameter measurements on the radiation dose level in chest tomosynthesis. Artificial ellipsoid-shaped nodules with known dimensions were inserted in clinical chest tomosynthesis images. Noise was added to the images in order to simulate radiation dose levels corresponding to effective doses for a standard-sized patient of 0.06 and 0.04 mSv. These levels were compared with the original dose level, corresponding to an effective dose of 0.12 mSv for a standard-sized patient. Four thoracic radiologists measured the longest diameter of the nodules. The study was restricted to nodules located in high-dose areas of the tomosynthesis projection radiographs. A significant decrease of the measurement accuracy and intra-observer variability was seen for the lowest dose level for a subset of the observers. No significant effect of dose level on the interobserver variability was found. The number of non-measurable small nodules (≤5 mm) was higher for the two lowest dose levels compared with the original dose level. In conclusion, for pulmonary nodules at positions in the lung corresponding to locations in high-dose areas of the projection radiographs, using a radiation dose level resulting in an effective dose of 0.06 mSv to a standard-sized patient may be possible in chest tomosynthesis without affecting the accuracy and precision of nodule diameter measurements to any large extent. However, an increasing number of non-measurable small nodules (≤5 mm) with decreasing radiation dose may raise some concerns regarding an applied general dose reduction for chest tomosynthesis examinations in the clinical praxis. (authors)

  5. Measurement of discrete energy-level spectra in individual chemically synthesized gold nanoparticles

    DEFF Research Database (Denmark)

    Kuemmeth, Ferdinand; Bolotin, Kirill I; Shi, Su-Fei

    2008-01-01

    We form single-electron transistors from individual chemically synthesized gold nanoparticles, 5-15 nm in diameter, with monolayers of organic molecules serving as tunnel barriers. These devices allow us to measure the discrete electronic energy levels of individual gold nanoparticles that are......, by virtue of chemical synthesis, well-defined in their composition, size and shape. We show that the nanoparticles are nonmagnetic and have spectra in good accord with random-matrix-theory predictions taking into account strong spin-orbit coupling....

  6. Development of a technique for level measurement in pressure vessels using thermal probes and artificial neural networks

    International Nuclear Information System (INIS)

    Torres, Walmir Maximo

    2008-01-01

    A technique for level measurement in pressure vessels was developed using thermal probes with internal cooling and artificial neural networks (ANN's). This new concept of thermal probes was experimentally tested in an experimental facility (BETSNI) with two test sections, ST1 and ST2. Two different thermal probes were designed and constructed: concentric tubes probe and U tube probe. A data acquisition system (DAS) was assembled to record the experimental data during the tests. Steady state and transient level tests were carried out and the experimental data obtained were used as learning and recall data sets in the ANN's program RETRO-05 that simulate a multilayer perceptron with backpropagation. The results of the analysis show that the technique can be applied for level measurements in pressure vessel. The technique is applied for a less input temperature data than the initially designed to the probes. The technique is robust and can be used in case of lack of some temperature data. Experimental data available in literature from electrically heated thermal probe were also used in the ANN's analysis producing good results. The results of the ANN's analysis show that the technique can be improved and applied to level measurements in pressure vessels. (author)

  7. Predictive Validity of Curriculum-Based Measures for English Learners at Varying English Proficiency Levels

    Science.gov (United States)

    Kim, Jennifer Sun; Vanderwood, Michael L.; Lee, Catherine Y.

    2016-01-01

    This study examined the predictive validity of curriculum-based measures in reading for Spanish-speaking English learners (ELs) at various levels of English proficiency. Third-grade Spanish-speaking EL students were screened during the fall using DIBELS Oral Reading Fluency (DORF) and Daze. Predictive validity was examined in relation to spring…

  8. Serum Levels of sRAGE Are Associated with Body Measurements, but Not Glycemic Parameters in Patients with Prediabetes.

    Science.gov (United States)

    Guclu, Metin; Ali, Asuman; Eroglu, Derya Ustun; Büyükuysal, Sema Oral; Cander, Soner; Ocak, Nihal

    2016-02-01

    Our aim was to assess serum levels of the soluble receptor for advanced glycation end products (sRAGE) and to examine their association with anthropometric and metabolic parameters in patients with prediabetes and obese controls. The two study groups were composed of 42 patients with prediabetes and diabetic neuropathy and 42 age-, gender-, body weight (BW)-, and body mass index (BMI)-matched obese adults as the control group. Prediabetes was diagnosed by the following criteria issued by the American Diabetes Association: impaired fasting glucose [fasting plasma glucose (FPG) level of 100-125 mg/dL], impaired glucose tolerance (2 hr plasma glucose level of 140-199 mg/dL after a 75 grams oral glucose challenge), or a glycated hemoglobin (HbA1C) level of 5.7%-6.4%. There were no differences between the groups in terms of age, gender distribution, BW, or BMI. Despite these similarities, patients with prediabetes had higher FPG, HbA1c, and 2-hr postchallenge glucose levels, higher systolic and diastolic blood pressure, and larger waist and hip circumferences compared with the obese controls. Lipid measurements, complete blood counts, kidney and liver function tests, high-sensitivity C-reactive protein, and sRAGE levels were similar between the two groups. We found significant negative correlations between sRAGE levels and BW, BMI, waist and hip circumferences, waist-to-hip ratios, and low-density lipoprotein (LDL) cholesterol levels. There were no significant correlations with other parameters, including demographic, metabolic, and blood pressure measurements. In contrast to glycemic parameters, serum levels of sRAGE were negatively correlated with body measurements indicative of obesity in the prediabetic state. In addition, the negative correlation with LDL cholesterol levels suggests that sRAGE has a more robust association with metabolic syndrome than with prediabetes.

  9. The challenge of measuring emergency preparedness: integrating component metrics to build system-level measures for strategic national stockpile operations.

    Science.gov (United States)

    Jackson, Brian A; Faith, Kay Sullivan

    2013-02-01

    Although significant progress has been made in measuring public health emergency preparedness, system-level performance measures are lacking. This report examines a potential approach to such measures for Strategic National Stockpile (SNS) operations. We adapted an engineering analytic technique used to assess the reliability of technological systems-failure mode and effects analysis-to assess preparedness. That technique, which includes systematic mapping of the response system and identification of possible breakdowns that affect performance, provides a path to use data from existing SNS assessment tools to estimate likely future performance of the system overall. Systems models of SNS operations were constructed and failure mode analyses were performed for each component. Linking data from existing assessments, including the technical assistance review and functional drills, to reliability assessment was demonstrated using publicly available information. The use of failure mode and effects estimates to assess overall response system reliability was demonstrated with a simple simulation example. Reliability analysis appears an attractive way to integrate information from the substantial investment in detailed assessments for stockpile delivery and dispensing to provide a view of likely future response performance.

  10. A novel method for morphological pleomorphism and heterogeneity quantitative measurement: Named cell feature level co-occurrence matrix.

    Science.gov (United States)

    Saito, Akira; Numata, Yasushi; Hamada, Takuya; Horisawa, Tomoyoshi; Cosatto, Eric; Graf, Hans-Peter; Kuroda, Masahiko; Yamamoto, Yoichiro

    2016-01-01

    Recent developments in molecular pathology and genetic/epigenetic analysis of cancer tissue have resulted in a marked increase in objective and measurable data. In comparison, the traditional morphological analysis approach to pathology diagnosis, which can connect these molecular data and clinical diagnosis, is still mostly subjective. Even though the advent and popularization of digital pathology has provided a boost to computer-aided diagnosis, some important pathological concepts still remain largely non-quantitative and their associated data measurements depend on the pathologist's sense and experience. Such features include pleomorphism and heterogeneity. In this paper, we propose a method for the objective measurement of pleomorphism and heterogeneity, using the cell-level co-occurrence matrix. Our method is based on the widely used Gray-level co-occurrence matrix (GLCM), where relations between neighboring pixel intensity levels are captured into a co-occurrence matrix, followed by the application of analysis functions such as Haralick features. In the pathological tissue image, through image processing techniques, each nucleus can be measured and each nucleus has its own measureable features like nucleus size, roundness, contour length, intra-nucleus texture data (GLCM is one of the methods). In GLCM each nucleus in the tissue image corresponds to one pixel. In this approach the most important point is how to define the neighborhood of each nucleus. We define three types of neighborhoods of a nucleus, then create the co-occurrence matrix and apply Haralick feature functions. In each image pleomorphism and heterogeneity are then determined quantitatively. For our method, one pixel corresponds to one nucleus feature, and we therefore named our method Cell Feature Level Co-occurrence Matrix (CFLCM). We tested this method for several nucleus features. CFLCM is showed as a useful quantitative method for pleomorphism and heterogeneity on histopathological image

  11. Measurements of natural levels of 14C in human's and rat's tissues by accelerator mass spectrometry in Korea

    International Nuclear Information System (INIS)

    Cho, S.Y.; Khu, H.J.; Kang, J.H.; Yoon, M.Y.; Kim, J.C.

    2005-01-01

    Accelerator mass spectrometry (AMS) is the most sensitive, safe and precise analytical method for quantifying long-lived isotope in biomedical research with animals as well as human beings. In Korea, AMS Laboratory has been operating successfully for years measuring especially archaeological samples for 14 C dating. In this year, a biological sample pretreatment facility was setup to work on biomedical applications. As a preliminary study, we have measured the natural background levels of 14 C in tissues and blood of humans and rats have been measured. The results were agreed with the other reported levels and gave stable and reproducible results within 1-2%. (author)

  12. The need for national diagnostic reference levels: entrance surface dose measurement in intraoral radiography

    International Nuclear Information System (INIS)

    Mortazavi, S. M. J.; Shareghi, A.; Kavousi, A.; Ghiassi-Nejad, M.; Jafari-Zadeh, M.; Nazeri, F.; Mozdarani, H.

    2004-01-01

    Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection recommendations, the selection of a diagnostic reference level should be specific to a country or region. Critical organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low as reasonably achievable. To assist the development of DRLs for intraoral radiography, a National Radiation Protection Department-sponsored pilot study was carried out. Materials and methods: thermoluminescent dosimetry is widely acknowledged to be the recommended method for measuring entrance surface doses. In this study, entrance surface doses was measured using LiF thermoluminescent dosimeters on the skin (either mandibular or maxillary arcs) of 40 patients. Three thermoluminescent dosimetry chips were placed on the skin of each patient. The doses were averaged for each radiography and mean entrance surface doses of all patients calculated. Results: the mean ±SD entrance surface dose at the center of the beam on the patient's skin in intraoral radiography was 1.173 ±0.606 mGy (ranged from 0.01 o 0.40 m Gy). The mean entrance surface doses for male and female patients were 1.380± 0.823, and 1.004± 0.258 respectively. No statistically significant difference was found between these means. Despite its necessity , in national level , there is no published data on the diagnostic reference levels for intraoral radiography. However, the results obtained in this study are lower than those reported by investigators in other countries. Conclusion: in IR Iran , due to lack of large scale studies, no diagnostic reference levels have been set for X-ray diagnostic procedures. Due to lack of national diagnostic reference levels, it is not possible to clarify whether in intraoral radiographies any dose reduction techniques are needed. We intend to perform similar nationwide studies to set the

  13. International symposium on low level measurements of radionuclides in the environment, 2004

    International Nuclear Information System (INIS)

    2004-01-01

    The International Symposium of Low-Level Measurements of Radionuclides in the Environment was held on April 19-23, 2004 in Guilin, China, and sponsored by the Chinese Nuclear Society. The articles are published in the form of abstracts, and the contents include: 1. special lectures; 2.Environmental Radioanalysis; 3. Concentration and migration of radionuclides; 4. Analysis with instrumentation and applications; 5. preparation of samples and trace in living beings; 6. Environment impact assessment and calculation of dose; 7. Decommissioning, monitoring in emergency condition and others

  14. Torque Measurement at the Single Molecule Level

    Science.gov (United States)

    Forth, Scott; Sheinin, Maxim Y.; Inman, James; Wang, Michelle D.

    2017-01-01

    Methods for exerting and measuring forces on single molecules have revolutionized the study of the physics of biology. However, it is often the case that biological processes involve rotation or torque generation, and these parameters have been more difficult to access experimentally. Recent advances in the single molecule field have led to the development of techniques which add the capability of torque measurement. By combining force, displacement, torque, and rotational data, a more comprehensive description of the mechanics of a biomolecule can be achieved. In this review, we highlight a number of biological processes for which torque plays a key mechanical role. We describe the various techniques that have been developed to directly probe the torque experienced by a single molecule, and detail a variety of measurements made to date using these new technologies. We conclude by discussing a number of open questions and propose systems of study which would be well suited for analysis with torsional measurement techniques. PMID:23541162

  15. Clinical significance of measurement of serum TNF-α, T, FSH and PRL levels in male infertility

    International Nuclear Information System (INIS)

    Li Tianquan; Zhou Minglian; He Haoming

    2011-01-01

    Objective: To explore the significance of changes of serum TNF-α, T, FSH and PRL levels in male patients with infertility. Methods: Serum TNF-α, T, FSH and PRL (with RIA) were measured in 36 male patients with infertility and 35 male controls. Results: Serum T level was significantly lower in the patients than those in controls (P<0.01), while the serum TNF-α, FSH and PRL levels were significantly higher in the patients (P<0.01). Serum TNF-α level was negatively correlated with T level in the patients (r=-0.5184, P<0.01) and positively correlated with FSH, PRL levels (r=0.6184, 0.5925, P<0.01). Conclusion: Serum TNF-α, T, FSH and PRL levels were significantly changed in male with infertility and determination of which might useful for prognosis and treatment clinically. (authors)

  16. Measurement of Non-Invasive Blood Glucose Level Based Sensor Color TCS3200 and Arduino

    Science.gov (United States)

    Kurniadi Wardana, Humaidillah; Indahwati, Elly; Arifah Fitriyah, Lina

    2018-04-01

    Design and measurement of Arduino-based urinary (non-invasive) urine glucose using RGB tcs3200 sensor. This research was conducted by making use of the urine in diabetes patients detected by sensor colours then measured levels of colour based on the RGB colour of the urine of diabetics. The detection is done on 4 urine samples with each consisting of 3 diabetics and 1 non-diabetics. Equipment used in this research, among others, Arduino Uno, colour sensor tcs3200, LCD 16x4. The results showed that the detection of RGB values in diabetics 230 with blue and not diabetics 200 with red.

  17. Measurement of cesium emissions during the vitrification of simulated high level radioactive waste

    International Nuclear Information System (INIS)

    Zamecnik, J.R.; Miller, D.H.; Carter, J.T.

    1992-01-01

    In the Defense Waste Processing Facility at the Savannah River Site, it is desired to eliminate a startup test that would involve adding small amounts of radioactive cesium-137 to simulated high-level waste. In order to eliminate this test, a reliable method for measuring non-radioactive cesium in the offgas system from the glass melter is required. From a pilot scale melter system, offgas particulate samples were taken on filter paper media and analyzed by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). The ICPMS method proved to be sufficiently sensitive to measure cesium quantities as low as 0.135 μg, with the sensitivity being limited by the background cesium present in the filter paper. Typical particulate loadings ranged from 800 μg of cesium. This sensitivity allowed determination of cesium decontamination factors for four of the five major components of the offgas system. The decontamination factors measured experimentally compared favorably with the process design basis values

  18. The Level of Power Quality Measurement and Evaluation in A Stone Crusher Plant

    Directory of Open Access Journals (Sweden)

    Mustafa ŞEKKELİ

    2009-03-01

    Full Text Available Both electric utilities and end users of electric power are becoming increasingly concerned about the quality of electric power. Quality of electrical energy in the electrical system that is requested continuous power (uninterrupted power, constant frequency and with constant amplitude can be explained by sinusoidal voltage. Deformation of voltage in the form of sinusoidal waveform is explained as a harmonic. Harmonics are most important factors in decreasing quality of energy in the electrical system. In industrial plants, existence of harmocins and voltage drop, causes serious problems both in plant and network. This problem affects the cost. In this study, a power quality measurements are carried out in stone crusher plant. Harmonics and voltage drop has been measured and evaluated with the power analyzer. In the power quality measurements, harmonic level of the plant is not so bad. However, it is recommended that compensation system with harmonic elimination can be established in plant.

  19. Energy Levels, wavelengths and hyperfine structure measurements of Sc II

    Science.gov (United States)

    Hala, Fnu; Nave, Gillian

    2018-01-01

    Lines of singly ionized Scandium (Sc II) along with other Iron group elements have been observed [1] in the region surrounding the massive star Eta Carinae [2,3] called the strontium filament (SrF). The last extensive analysis of Sc II was the four-decade old work of Johansson & Litzen [4], using low-resolution grating spectroscopy. To update and extend the Sc II spectra, we have made observation of Sc/Ar, Sc/Ne and Sc/Ge/Ar hollow cathode emission spectrum on the NIST high resolution FT700 UV/Vis and 2 m UV/Vis/IR Fourier transform spectrometers (FTS). More than 850 Sc II lines have been measured in the wavelength range of 187 nm to 3.2 μm. connecting a total of 152 energy levels. The present work also focuses to resolve hyperfine structure (HFS) in Sc II lines. We aim to obtain accurate transition wavelengths, improved energy levels and HFS constants of Sc II. The latest results from work in progress will be presented.Reference[1] Hartman H, Gull T, Johansson S and Smith N 2004 Astron. Astrophys. 419 215[2] Smith N, Morse J A and Gull T R 2004 Astrophys. J. 605 405[3] Davidson K and Humphreys R M 1997 Annu. Rev. Astron. Astrophys. 35[4] Johansson S and Litzén U 1980 Phys. Scr. 22 49

  20. A detector for monitoring the onset of cavitation during therapy-level measurements of ultrasonic power

    Energy Technology Data Exchange (ETDEWEB)

    Hodnett, M; Zeqiri, B [National Physical Laboratory, Queens Road, Teddington, Middlesex, TW11 0LW (United Kingdom)

    2004-01-01

    Acoustic cavitation occurring in the water path between a transducer and the target of a radiation force balance can provide a significant source of error during measurements of ultrasonic power. These problems can be particularly acute at physiotherapy levels (>1 W), and low frequencies ({<=} 1 MHz). The cavitating bubbles can absorb and scatter incident ultrasound, leading to an underestimate in the measured power. For these reasons, International Specification standards demand the use of degassed water. This imposes requirements that may actually be difficult to meet, for example, in the case of hospitals. Also, initially degassed water will rapidly re-gas, increasing the likelihood of cavitation occurring. For these reasons, NPL has developed a device that monitors acoustic emissions generated by bubble activity, for detecting the onset of cavitation during power measurements. A commercially available needle hydrophone is used to detect these emissions. The acoustic signals are then monitored using a Cavitation Detector (CD) unit, comprising an analogue electrical filter that may be tuned to detect frequency components generated by cavitating bubbles, and which provides an indication of when the measured level exceeds a pre-defined threshold. This paper describes studies to establish a suitable detection scheme, the principles of operation of the CD unit, and the performance tests carried out with a range of propagation media.

  1. A detector for monitoring the onset of cavitation during therapy-level measurements of ultrasonic power

    International Nuclear Information System (INIS)

    Hodnett, M; Zeqiri, B

    2004-01-01

    Acoustic cavitation occurring in the water path between a transducer and the target of a radiation force balance can provide a significant source of error during measurements of ultrasonic power. These problems can be particularly acute at physiotherapy levels (>1 W), and low frequencies (≤ 1 MHz). The cavitating bubbles can absorb and scatter incident ultrasound, leading to an underestimate in the measured power. For these reasons, International Specification standards demand the use of degassed water. This imposes requirements that may actually be difficult to meet, for example, in the case of hospitals. Also, initially degassed water will rapidly re-gas, increasing the likelihood of cavitation occurring. For these reasons, NPL has developed a device that monitors acoustic emissions generated by bubble activity, for detecting the onset of cavitation during power measurements. A commercially available needle hydrophone is used to detect these emissions. The acoustic signals are then monitored using a Cavitation Detector (CD) unit, comprising an analogue electrical filter that may be tuned to detect frequency components generated by cavitating bubbles, and which provides an indication of when the measured level exceeds a pre-defined threshold. This paper describes studies to establish a suitable detection scheme, the principles of operation of the CD unit, and the performance tests carried out with a range of propagation media

  2. Socioeconomic status in children is associated with hair cortisol levels as a biological measure of chronic stress.

    Science.gov (United States)

    Vliegenthart, J; Noppe, G; van Rossum, E F C; Koper, J W; Raat, H; van den Akker, E L T

    2016-03-01

    Low socioeconomic status (SES) may be associated with a high risk of lifestyle-related diseases such as cardiovascular diseases. There is a strong association between parental SES, stress and indicators of child health and adult health outcome. The exact mechanisms underlying this association have not yet been fully clarified. Low SES may be associated with chronic stress, which may lead to activation of the hypothalamic-pituitary-adrenal (HPA)-axis, resulting in a higher circulating level of the stress hormone cortisol. Therefore, chronic stress may mediate the association between low SES and elevated cortisol levels and its adverse outcomes. We investigated whether SES was associated with a chronic measure of cortisol exposure in a child population. Cortisol and cortisone were measured in scalp hair in 270 children and adolescents, aged 4-18 years, enrolled through school visits. Neighborhood level SES was based on a score developed by the Netherlands Institute for Social Research using postal codes, and this includes neighborhood measures of income education and unemployment. Maternal and paternal education level were used as indicators of family SES. Neighborhood level socioeconomic status score was significantly associated with hair cortisol (β=-0.103, p=0.007, 95%CI [-0.179, -0.028]) and hair cortisone (β=-0.091, p=0.023, 95%CI [-0.167, -0.015]), adjusted for age and sex. Additionally, hair cortisol was significantly correlated with maternal education level and hair cortisone was significantly correlated with paternal education level. The results of our study suggest that the widely shown association between low family SES and adverse child health outcomes may be mediated by chronic stress, given the chronically higher levels of cortisol in children and adolescents in families with low SES. It is especially notable that the association between SES and cortisol was already found in children of young age as this can have major consequences, such as increased

  3. The statistical interpretations of counting data from measurements of low-level radioactivity

    International Nuclear Information System (INIS)

    Donn, J.J.; Wolke, R.L.

    1977-01-01

    The statistical model appropriate to measurements of low-level or background-dominant radioactivity is examined and the derived relationships are applied to two practical problems involving hypothesis testing: 'Does the sample exhibit a net activity above background' and 'Is the activity of the sample below some preselected limit'. In each of these cases, the appropriate decision rule is formulated, procedures are developed for estimating the preset count which is necessary to achieve a desired probability of detection, and a specific sequence of operations is provided for the worker in the field. (author)

  4. High-voltage measurements on the 5 ppm relative uncertainty level with collinear laser spectroscopy

    Science.gov (United States)

    Krämer, J.; König, K.; Geppert, Ch; Imgram, P.; Maaß, B.; Meisner, J.; Otten, E. W.; Passon, S.; Ratajczyk, T.; Ullmann, J.; Nörtershäuser, W.

    2018-04-01

    We present the results of high-voltage collinear laser spectroscopy measurements on the 5 ppm relative uncertainty level using a pump and probe scheme at the 4s ^2S1/2 → 4p ^2P3/2 transition of {\\hspace{0pt}}40Ca+ involving the 3d ^2D5/2 metastable state. With two-stage laser interaction and a reference measurement we can eliminate systematic effects such as differences in the contact potentials due to different electrode materials and thermoelectric voltages, and the unknown starting potential of the ions in the ion source. Voltage measurements were performed between  -5 kV and  -19 kV and parallel measurements with stable high-voltage dividers calibrated to 5 ppm relative uncertainty were used as a reference. Our measurements are compatible with the uncertainty limits of the high-voltage dividers and demonstrate an unprecedented (factor of 20) increase in the precision of direct laser-based high-voltage measurements.

  5. Pico-coulomb charge measured at BELLA to percent-level precision using a Turbo-ICT

    International Nuclear Information System (INIS)

    Nakamura, K; Mittelberger, D E; Gonsalves, A J; Daniels, J; Mao, H-S; Leemans, W P; Stulle, F; Bergoz, J

    2016-01-01

    Precise diagnostics of picocoulomb level particle bunches produced by laser plasma accelerators (LPAs) can be a significant challenge. Without proper care, the small signals associated with such bunches can be dominated by a background generated by laser, target, laser–plasma interaction and particle induced radiation. In this paper, we report on first charge measurements using the newly developed Turbo-ICT for LPAs. We outline the Turbo-ICT working principle, which allows precise sub-picocoulomb measurements even in the presence of significant background signals. A comparison of the Turbo-ICT, a conventional integrating current transformer (ICT) and a scintillating screen (Lanex) was carried out at the Berkeley Lab Laser Accelerator. Results show that the Turbo-ICT can measure sub-picocoulomb charge accurately and has significantly improved noise immunity compared to the ICT. (paper)

  6. Pico-coulomb charge measured at BELLA to percent-level precision using a Turbo-ICT

    Science.gov (United States)

    Nakamura, K.; Mittelberger, D. E.; Gonsalves, A. J.; Daniels, J.; Mao, H.-S.; Stulle, F.; Bergoz, J.; Leemans, W. P.

    2016-03-01

    Precise diagnostics of picocoulomb level particle bunches produced by laser plasma accelerators (LPAs) can be a significant challenge. Without proper care, the small signals associated with such bunches can be dominated by a background generated by laser, target, laser-plasma interaction and particle induced radiation. In this paper, we report on first charge measurements using the newly developed Turbo-ICT for LPAs. We outline the Turbo-ICT working principle, which allows precise sub-picocoulomb measurements even in the presence of significant background signals. A comparison of the Turbo-ICT, a conventional integrating current transformer (ICT) and a scintillating screen (Lanex) was carried out at the Berkeley Lab Laser Accelerator. Results show that the Turbo-ICT can measure sub-picocoulomb charge accurately and has significantly improved noise immunity compared to the ICT.

  7. Infiltration and air quality in well-insulated homes: 3. measurement and modeling of pollutant levels

    International Nuclear Information System (INIS)

    Koontz, M.D.; Nagda, N.L.

    1984-01-01

    Indoor pollutant levels in well-insulated houses are being investigated in a 2-year theoretical and experimental study involving the simultaneous measurement of meteorological variables, air exchange and circulation, and energy consumption. This paper describes concentrations of radon, radon progeny, formaldehyde, carbon monoxide, and nitrogen oxides observed in two houses over two seasons, summer and fall 1983. Two companion papers provide a perspective on the problem and the study design, and present results of energy use and infiltration measurements. (Author)

  8. Respirometry increases cortisol levels in rainbow trout Oncorhynchus mykiss: implications for measurements of metabolic rate

    DEFF Research Database (Denmark)

    Murray, L.; Rennie, M. D.; Svendsen, Jon Christian

    2017-01-01

    This study aimed to assess the extent to which chasing, handling and confining Oncorhynchus mykiss to a small respirometer chamber during respirometric experiments is stressful and affects metabolic measurements. The study observed increased cortisol levels in animals tested using a chase protocol...

  9. Measurement of the solar ultraviolet radiation at ground level in Bangi, Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Aljawi, Ohoud; Gopir, Geri; Duay, Abdul Basit [School of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor, Malaysia. ohoud-aljawi@hotmail.com (Malaysia)

    2015-04-24

    Understanding the amount of ultraviolet (UV) radiation received by human, plant, and animal organisms near the earth’s surface is important to a wide range of fields such as cancer research, agriculture and forestry. The solar ultraviolet spectral irradiance at ground level was measured using the Avantes spectrometer for the period of January to March 2014 at Bangi (2°55´N, 101°46´E, 50 m above sea level) in Malaysia. These data were used to estimate the diurnal variation of UV irradiance (300 – 400 nm). The maximum irradiance of UV radiation was 45 W m{sup −2} on horizontal surface. The maximum irradiance of UV received in the local noon time, and the minimum values of UV irradiance was received in the local morning time. It is found a bigger value of UV radiation was observed on clear sky in January. The estimation of daily flux average of UV irradiance was (921± 91) kJ m{sup −2}.

  10. Measurement of Platelet-derived Microparticle Levels in the Chronic Phase of Cerebral Infarction Using an Enzyme-linked Immunosorbent Assay

    OpenAIRE

    Shirafuji, Toshihiko; Hamaguchi, Hirotoshi; Kanda, Fumio

    2008-01-01

    Assessment of platelet function is a critical component of the treatment andsecondary prevention of cerebral infarction, and measurement of platelet-derivedmicroparticle (PDMP) levels using flow cytometry may be a good indicator of plateletfunction. However, the flow cytometric analysis is not feasible in a variety of clinicalsituations. The goal of the present study was to measure PDMP levels using anenzyme-linked immunosorbent assay (ELISA) in chronic cerebral infarction patientsand to dete...

  11. A Half-Life Measurement of the 343.4 keV Level in {sup 175}Lu

    Energy Technology Data Exchange (ETDEWEB)

    Hoejeberg, M; Malmskog, S G

    1969-05-15

    Great theoretical interest has recently been shown in the asymptotically forbidden 5/2 5/2+ [402] - 7/2 7/2+ [404] M1-transitions in {sup 181}Ta and {sup 175}Lu . Half-lives of the 5/2 5/2+ [402] level in {sup 175}Lu have been reported which differ by more than a factor of 10. Using an electron-electron coincidence spectrometer the half-life of this level has been re-measured and a value of (0.26 {+-} 0.02) nsec has been established.

  12. Interpretation of low-level environmental radioactivity measurements

    International Nuclear Information System (INIS)

    Zeigler, C.C.

    1982-01-01

    Levels of radioactivity in the environment from worldwide fallout have decreased by about a factor of 10 since the early 1970's and many environmental concentrations are now less than the routine estimated lower limit of detection. To accurately represent these data and to assist in evaluating very low levels of radioactivity, each instrumental value with its statistical counting error should be reported. In some instances the background count of the instrument exceeds the sample count resulting in a value that is less than zero (a negative concentration). Evaluation of these negative numbers along with zero and positive concentrations over a suitable sample population can yield important information about concentrations that are less than routine minimum levels of detection. Actual instrumental values (negative, zero and positive) with associated statistical counting errors have been reported by the Environmental Monitoring Group at the Savannah River Plant since 1977. Methods for evaluating these data are discussed and empirical data presented to illustrate important points

  13. Evaluation method for corrosion level of rebar in RC with electrical impedance measurement

    Science.gov (United States)

    Sasamoto, Akira

    2018-04-01

    The author reported that the impedance measurement using the 4-terminal method on the RC surface for diagnosing corrosion of internal rebar. The difference between the maximum value at 0.01 Hz and the minimum value around 10 Hz indicates the corrosion level of rebar in that report. This is successive report on a signal processing method for estimating the corrosion level by the measured impedance data to obtain more high accuracy. In the dielectric, a graph of frequency and dielectric constant (Cole-Cole plot diagram by KS Cole and RH Cole article of 1941) draws a shape of circle if the dielectric is independent of frequency but it draws a shape of ellipse in reality due to frequency dependency. Havriliak and Negami have also presented Havriliak-Negami model which introduced parameter into dielectric constant equation which deforms Cole-Cole plot diagram and showed that acquired dielectric data of polymer materials fit to this model with proper parameters. In this report, we first consider electric model connected with resistance and capacitance as a rough model of RC concrete. If the capacitance in this model circuit has some loss of dielectric, it is stated that graph in impedance plot is expected to take as similar deformation in the dielectric Cole-Cole plot. Then a numerical optimization computer code for obtaining parameters in the Cole-Cole plot diagram and Havriliak-Negami model is constructed, and the correlation between the deformation parameter of each model and corrosion is shown by this code. These results are feasibility study for diagnosis of corrosion level of rebar by associated parameters to a shape of impedance graph.

  14. Advanced Quadrupole Ion Trap Instrumentation for Low Level Vehicle Emissions Measurements

    International Nuclear Information System (INIS)

    McLuckey, S.A.

    1997-01-01

    Quadrupole ion trap mass spectrometry has been evaluated for its potential use in vehicle emissions measurements in vehicle test facilities as an analyzer for the top 15 compounds contributing to smog generation. A variety of ionization methods were explored including ion trap in situ chemical ionization, atmospheric sampling glow discharge ionization, and nitric oxide chemical ionization in a glow discharge ionization source coupled with anion trap mass spectrometer. Emphasis was placed on the determination of hydrocarbons and oxygenated hydrocarbons at parts per million to parts per billion levels. Ion trap in situ water chemical ionization and atmospheric sampling glow discharge ionization were both shown to be amendable to the analysis of arenes, alcohols, aldehydes and, to some degree, alkenes. Atmospheric sampling glow discharge also generated molecular ions of methy-t-butyl ether (MTBE). Neither of these ionization methods, however, were found to generate diagnostic ions for the alkanes. Nitric oxide chemical ionization, on the other hand, was found to yield diagnostic ions for alkanes, alkenes, arenes, alcohols, aldehydes, and MTBE. The ability to measure a variety of hydrocarbons present at roughly 15 parts per billion at measurement rates of 3 Hz was demonstrated. All of the ions with potential to serve as parent ions in a tandem mass spectrometry experiment were found to yield parent-to-product conversion efficiencies greater than 75%. The flexibility afforded to the ion trap by use of tailored wave-forms applied to the end-caps allows parallel monitoring schemes to be devised that provide many of the advantages of tandem mass spectrometry without major loss in measurement rate. A large loss in measurement rate would ordinarily result from the use of conventional tandem mass spectrometry experiments carried out in series for a large number of targeted components. These results have demonstrated that the ion trap has an excellent combination of

  15. Design and evaluation of three-level composite filters obtained by optimizing a compromise average performance measure

    Science.gov (United States)

    Hendrix, Charles D.; Vijaya Kumar, B. V. K.

    1994-06-01

    Correlation filters with three transmittance levels (+1, 0, and -1) are of interest in optical pattern recognition because they can be implemented on available spatial light modulators and because the zero level allows us to include a region of support (ROS). The ROS can provide additional control over the filter's noise tolerance and peak sharpness. A new algorithm based on optimizing a compromise average performance measure (CAPM) is proposed for designing three-level composite filters. The performance of this algorithm is compared to other three-level composite filter designs using a common image database and using figures of merit such as the Fisher ratio, error rate, and light efficiency. It is shown that the CAPM algorithm yields better results.

  16. Measuring and managing the work environment of the mid-level provider – the neglected human resource

    Directory of Open Access Journals (Sweden)

    McAuliffe Eilish

    2009-02-01

    Full Text Available Abstract Background Much has been written in the past decade about the health workforce crisis that is crippling health service delivery in many middle-income and low-income countries. Countries having lost most of their highly qualified health care professionals to migration increasingly rely on mid-level providers as the mainstay for health services delivery. Mid-level providers are health workers who perform tasks conventionally associated with more highly trained and internationally mobile workers. Their training usually has lower entry requirements and is for shorter periods (usually two to four years. Our study aimed to explore a neglected but crucial aspect of human resources for health in Africa: the provision of a work environment that will promote motivation and performance of mid-level providers. This paper explores the work environment of mid-level providers in Malawi, and contributes to the validation of an instrument to measure the work environment of mid-level providers in low-income countries. Methods Three districts were purposively sampled from each of the three geographical regions in Malawi. A total of 34 health facilities from the three districts were included in the study. All staff in each of the facilities were included in the sampling frame. A total of 153 staff members consented to be interviewed. Participants completed measures of perceptions of work environment, burnout and job satisfaction. Findings The Healthcare Provider Work Index, derived through Principal Components Analysis and Rasch Analysis of our modification of an existing questionnaire, constituted four subscales, measuring: (1 levels of staffing and resources; (2 management support; (3 workplace relationships; and (4 control over practice. Multivariate analysis indicated that scores on the Work Index significantly predicted key variables concerning motivation and attrition such as emotional exhaustion, job satisfaction, satisfaction with the profession

  17. A Methodology to Measure Synergy Among Energy-Efficiency Programs at the Program Participant Level

    Energy Technology Data Exchange (ETDEWEB)

    Tonn, B.E.

    2003-11-14

    This paper presents a methodology designed to measure synergy among energy-efficiency programs at the program participant level (e.g., households, firms). Three different definitions of synergy are provided: strong, moderate, and weak. Data to measure synergy can be collected through simple survey questions. Straightforward mathematical techniques can be used to estimate the three types of synergy and explore relative synergistic impacts of different subsets of programs. Empirical research is needed to test the concepts and methods and to establish quantitative expectations about synergistic relationships among programs. The market for new energy-efficient motors is the context used to illustrate all the concepts and methods in this paper.

  18. Radioactivity level and soil radon measurement of a volcanic area in Cameroon

    International Nuclear Information System (INIS)

    Ngachin, M.; Garavaglia, M.; Giovani, C.; Kwato Njock, M.G.; Nourreddine, A.

    2008-01-01

    The radioactivity level of soils in a volcanic area in Cameroon was determined and discussed. Thirty soils samples were collected from Buea and Limbe cities located in the south-western Cameroon. These two regions are known for theirs volcanic grounds due to the presence of Mount Cameroon Mountain. The activity concentrations of natural radionuclides as well as that of the fission product were evaluated by gamma-ray spectrometry using a hyper-purity germanium detector (HPGe). The ranges of concentrations in the surveyed soils were 11-17 Bq kg -1 , 22-36 Bq kg -1 and 43-201 Bq kg -1 for 226 Ra, 232 Th and 40 K, respectively. The radioisotope 137 Cs was also found but in a very small amount. The outdoor absorbed dose rate 1 m above ground with the corresponding annual effective dose rate, assuming a 20% occupancy factor was estimated. The radium equivalent and the external hazard index were also evaluated and results are compared with available data from other studies and with the world average value [United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), 1988. Sources, Effects and Risks of Ionizing Radiation. Report to the General Assembly on the Effects of Atomic Radiation. United Nations, New York; UNSCEAR, 2000. Sources and Effects of Ionizing Radiations. Report to the General Assembly with Scientific Annexes. United Nations, New York]. A solid state nuclear track detector (SSNTD), LR-115 was used for soil radon measurements at a depth of 50 cm. The ranges of soil radon concentrations were 6.7-10.8 kBq m -3 and 5.5-8.7 kBq m -3 in Buea and Limbe, respectively. A positive correlation was found between concentrations of radium measured with γ-spectrometry and the soil radon concentrations measured with the nitrate cellulose detectors. The results of this study provide the radioactivity level in soil of a volcanic area, which has been found to be within the safety limits. The south-western Cameroon can be considered as having normal

  19. Challenging the present definition of "normal" vitamin D levels obtained by a single blood test. Can we develop a formula to predict vitamin D levels in the 4 seasons from a single season's measure?

    Science.gov (United States)

    Tandeter, Howard

    2014-08-01

    Publications on the health effects of vitamin D (25(OH) D) had almost triplicate in the last 10years, not only for its known "calcemic effects" (calcium, phosphor, PTH), but for the more recent findings on its "non-calcemic effects" (all-cause and cardiovascular mortality, and relation with certain types of cancer). Part of these publications deal with the definition of what is a "normal" circulating level of 25(OH) D that may distinguish between health and disease. The literature also deals with seasonal variations of vitamin D, showing levels that rise in summer and fall in winter and with DBP phenotypes and geographical location that affect seasonality of 25(OH) D measurements. Despite the knowledge of the existence of these phenomena many studies on vitamin D fail to acknowledge the time of the year the blood sample was extracted. Thus, when we compare results from different studies without defining the season that the samples were drawn, we compare incomparable figures. Furthermore, it is quite absurd to define "normal levels" as a static measure (over or under a certain value) using a single blood test when the value measured is known to change with seasons. Knowing that people have different vitamin D levels in different seasons of the year, we should ask ourselves which of these measurements should be used to define a "real" or "normal" level? Is it the lower one? Is there a "mean measure" that should be used for this matter? If yes, how do we obtain it? Do we have to make 4 seasonal measurements in each patient? Alternatively, might there be a possibility of developing a formula to help us obtain the mean from a single season's measure or one season's prediction from another season's measurement? And knowing that DBP phenotypes and geographical location affect seasonality of 25(OH) D measurements; shouldn't we include this in the equation? In this article I will discuss the hypothetical existence of an Individual Mean Annual vitamin D level that I will

  20. Measurement of methionine level with the LC-ESI-MS/MS method in schizophrenic patients.

    Science.gov (United States)

    Kulaksizoglu, S; Kulaksizoglu, B; Ellidag, H Y; Eren, E; Yilmaz, N; Baykal, A

    2016-01-01

    The purpose of this study was to evaluate plasma methionine levels by using liquid chromatography electrospray ionization-tandem mass spectroscopy (LC-ESI-MS/MS) in schizophrenic patients. A twelve-point standard graph was drawn, and the recovery rate, the intra-day and inter-day coefficients of variation (CV), the limit of detection (LOD), and the limit of quantification (LOQ) were evaluated. The y and R2 values of the standard graph equation were determined as 0.011x + 0.0179 and 0.9989, respectively, and the graph remained linear until the 200 µmol/l level. The intra-day coefficients of variation of the samples (n = 10) containing 8, 28, and 58 µmol/l methionine were determined as 2.68, 3.10, and 3.79%, respectively; while their inter-day coefficients of variation were determined as 2.98, 3.19, and 3.84%. The LOD and LOQ values were determined as 0.04 and 0.1 µmol/l, respectively, while the mean recovery rates were determined as 101.7 and 99.3%. Plasma methionine values were measured as 21.5 (19.5-24,6) µmol/l for the patient group, 17.8 (16.3-20.1) µmol/l for the control group, and the difference between the two groups was statistically significant (p = 0.03). LC-ESI-MS/MS method represents a fairly sensitive, economic, and rapid analysis that requires very little sample and is suitable for measuring methionine levels in schizophrenic patients.

  1. Measuring the Rate of Change in Sea Level and Its Adherence to USACE Sea Level Rise Planning Scenarios Using Timeseries Metrics

    Science.gov (United States)

    White, K. D.; Huang, N.; Huber, M.; Veatch, W.; Moritz, H.; Obrien, P. S.; Friedman, D.

    2017-12-01

    In 2013, the United States Army Corps of Engineers (USACE) issued guidance for all Civil Works activities to incorporate the effects of sea level change as described in three distinct planning scenarios.[1] These planning scenarios provided a useful framework to incorporate these effects into Civil Works activities, but required the manual calculation of these scenarios for a given gage and set of datum. To address this need, USACE developed the Sea Level Change Curve Calculator (SLCCC) in 2014 which provided a "simple, web-based tool to provide repeatable analytical results."[2]USACE has been developing a successor to the SLCCC application which retains the same, intuitive functionality to calculate these planning scenarios, but it also allows the comparison of actual sea level change between 1992 and today against the projections, and builds on the user's ability to understand the rate of change using a variety of timeseries metrics (e.g. moving averages, trends) and related visualizations. These new metrics help both illustrate and measure the complexity and nuances of sea level change. [1] ER 1000-2-8162. http://www.publications.usace.army.mil/Portals/76/Publications/EngineerRegulations/ER_1100-2-8162.pdf. [2] SLCC Manual. http://www.corpsclimate.us/docs/SLC_Calculator_Manual_2014_88.pdf.

  2. Measurements of environmental background radiation levels by TLD in and around the Jahangirnagar University Campus

    International Nuclear Information System (INIS)

    Mollah, A.S.; Aleya Begum; Idris Miah, M.; Yunus, Afrozi

    1997-01-01

    The background radiation levels at 30 locations in and around the Jahangirnagar University Campus (JUC) were measured using a LiF(TLD-100) thermoluminescent dosimeter (TLD). In addition, dose rates at three pre-selected locations were measured on a monthly as well as quarterly basis for one year period (July 1993 - June 1994). The dose rate ranges from 1016 to 2167 μSv.y -1 (101.6 to 216.7 mrem.y -1 ) with a mean value of 1595 μSv.y -1 (159.5 mrem.y -1 ). These values are comparable with those of pre- and post-operational values for the reactor site. The estimated average annual effective dose equivalent to the inhabitants at the study areas was found to be 1276 μSv (127.6 mrem). Variation of background radiation level with meteorological parameters, namely, temperature, rainfall, relative humidity and pressure was also studied. The influence on the dose rate of the meteorological parameters was observed. (author)

  3. Farmers Prone to Drought Risk: Why Some Farmers Undertake Farm-Level Risk-Reduction Measures While Others Not?

    Science.gov (United States)

    Gebrehiwot, Tagel; van der Veen, Anne

    2015-03-01

    This research investigates farmers' cognitive perceptions of risk and the behavioral intentions to undertake farm-level risk-reduction measures. It has been observed that people who are susceptible to natural hazards often fail to act, or do very little, to protect their assets or lives. To answer the question of why some people show adaptive behavior while others do not, a socio-psychological model of precautionary adaptation based on protection motivation theory and trans-theoretical stage model has been applied for the first time to areas of drought risk in the developing countries cultural context. The applicability of the integrated model is explored by means of a representative sample survey of smallholder farmers in northern Ethiopia. The result of the study showed that there is a statistically significant association between farmer's behavioral intention to undertake farm-level risk-reduction measures and the main important protection motivation model variables. High perceived vulnerability, severity of consequences, self-efficacy, and response efficacy lead to higher levels of behavioral intentions to undertake farm-level risk-reduction measures. For farmers in the action stage, self-efficacy and response efficacy were the main motivators of behavioral intention. For farmers in the contemplative stage, self-efficacy and cost appear to be the main motivators for them to act upon risk reduction, while perceived severity of consequences and cost of response actions were found to be important for farmers in the pre-contemplative stage.

  4. Process and device for measuring the level in a reactor pressure vessel of a boiling water reactor

    International Nuclear Information System (INIS)

    Walleser, A.

    1987-01-01

    The differential pressure is measured between the lower space filled with liquid and a comparison column which is connected to the upper part space filled with steam. From this measurement and the liquid and steam densities in the pressure vessel and in the comparison column and the effects of flow at the pressure sampling positions, the level is determined in an evaluation unit. To determine the densities of liquids and steam, the reactor pressure or the change of pressure with time for transient processes is measured. The density of the comparison column is determined by temperature measurement. The effects of flow are determined by flow measurements. All the measurements are taken to an evaluation unit. (orig./HP) [de

  5. Lab-on-a-Chip Device for Rapid Measurement of Vitamin D Levels.

    Science.gov (United States)

    Peter, Harald; Bistolas, Nikitas; Schumacher, Soeren; Laurisch, Cecilia; Guest, Paul C; Höller, Ulrich; Bier, Frank F

    2018-01-01

    Lab-on-a-chip assays allow rapid analysis of one or more molecular analytes on an automated user-friendly platform. Here we describe a fully automated assay and readout for measurement of vitamin D levels in less than 15 min using the Fraunhofer in vitro diagnostics platform. Vitamin D (25-hydroxyvitamin D 3 [25(OH)D 3 ]) dilution series in buffer were successfully tested down to 2 ng/mL. This could be applied in the future as an inexpensive point-of-care analysis for patients suffering from a variety of conditions marked by vitamin D deficiencies.

  6. Perspectives on repeated low-level blast and the measurement of neurotrauma in humans as an occupational exposure risk

    Science.gov (United States)

    Carr, W.; Dell, K. C.; Yanagi, M. A.; Hassan, D. M.; LoPresti, M. L.

    2017-11-01

    A pressing question in military medical research is the nature and degree of effects on the human brain from occupational repeated exposure to low-level explosive blast, but reliable and effective means to objectively measure such effects remain elusive. In survey results, headache, difficulty sleeping, irritability, cognitive impairment, and a variety of other symptoms consistent with post-concussive syndrome have been reported by those exposed to blast and there was positive correlation between degree of blast exposure and degree of symptomology, but an important goal is to obtain more objective evidence of an effect than self-report alone. This review reflects recent efforts to measure and evaluate such hypothesized effects and current recommendations for ongoing study. Optimal measures are likely those with sensitivity and specificity to systemic effects in mild neurotrauma, that have minimal to no volitional component, and that can be sampled relatively quickly with minimal intrusion in prospective, observational field studies during routine training with explosives. An understanding of an association between parameters of exposure to repeated low-level blast and negative neurologic effects would support the evaluation of clinical implications and development of protective equipment and surveillance protocols where warranted. At present, low-level blast exposure surveillance measurements do not exist as a systematic record for any professional community.

  7. Measurement invariance across educational levels and gender in 12-item Zarit Burden Interview (ZBI) on caregivers of people with dementia.

    Science.gov (United States)

    Lin, Chung-Ying; Ku, Li-Jung Elizabeth; Pakpour, Amir H

    2017-11-01

    The Zarit Burden Interview (ZBI) is a commonly used self-report to assess caregiver burden. A 12-item short form of the ZBI has been developed; however, its measurement invariance has not been examined across some different demographics. It is unclear whether different genders and educational levels of a population interpret the ZBI items similarly. Therefore, this study aimed to examine the measurement invariance of the 12-item ZBI across gender and educational levels in a Taiwanese sample. Caregivers who had a family member with dementia (n = 270) completed the ZBI through telephone interviews. Three confirmatory factor analysis (CFA) models were conducted: Model 1 was the configural model, Model 2 constrained all factor loadings, Model 3 constrained all factor loadings and item intercepts. Multiple group CFAs and the differential item functioning (DIF) contrast under Rasch analyses were used to detect measurement invariance across males (n = 100) and females (n = 170) and across educational levels of junior high schools and below (n = 86) and senior high schools and above (n = 183). The fit index differences between models supported the measurement invariance across gender and across educational levels (∆ comparative fit index (CFI) = -0.010 and 0.003; ∆ root mean square error of approximation (RMSEA) = -0.006 to 0.004). No substantial DIF contrast was found across gender and educational levels (value = -0.36 to 0.29). The ZBI is appropriate for combined use and for comparisons in caregivers across gender and different educational levels in Taiwan.

  8. Infrared analyzers for breast milk analysis: fat levels can influence the accuracy of protein measurements.

    Science.gov (United States)

    Kwan, Celia; Fusch, Gerhard; Bahonjic, Aldin; Rochow, Niels; Fusch, Christoph

    2017-10-26

    Currently, there is a growing interest in lacto-engineering in the neonatal intensive care unit, using infrared milk analyzers to rapidly measure the macronutrient content in breast milk before processing and feeding it to preterm infants. However, there is an overlap in the spectral information of different macronutrients, so they can potentially impact the robustness of the measurement. In this study, we investigate whether the measurement of protein is dependent on the levels of fat present while using an infrared milk analyzer. Breast milk samples (n=25) were measured for fat and protein content before and after being completely defatted by centrifugation, using chemical reference methods and near-infrared milk analyzer (Unity SpectraStar) with two different calibration algorithms provided by the manufacturer (released 2009 and 2015). While the protein content remained unchanged, as measured by elemental analysis, measurements by infrared milk analyzer show a difference in protein measurements dependent on fat content; high fat content can lead to falsely high protein content. This difference is less pronounced when measured using the more recent calibration algorithm. Milk analyzer users must be cautious of their devices' measurements, especially if they are changing the matrix of breast milk using more advanced lacto-engineering.

  9. Dependence centrality similarity: Measuring the diversity of profession levels of interests

    Science.gov (United States)

    Yan, Deng-Cheng; Li, Ming; Wang, Bing-Hong

    2017-08-01

    To understand the relations between developers and software, we study a collaborative coding platform from the perspective of networks, including follower networks, dependence networks and developer-project bipartite networks. Through the analyzing of degree distribution, PageRank and degree-dependent nearest neighbors' centrality, we find that the degree distributions of all networks have a power-law form except the out-degree distributions of dependence networks. The nearest neighbors' centrality is negatively correlated with degree for developers but fluctuates around the average for projects. In order to measure the diversity of profession levels of interests, a new index called dependence centrality similarity is proposed and the correlation between dependence centrality similarity and degree is investigated. The result shows an obvious negative correlations between dependence centrality similarity and degree.

  10. Proton energy spectra during ground level enhancements as measured by EPHIN aboard SOHO

    Energy Technology Data Exchange (ETDEWEB)

    Heber, Bernd; Kuehl, Patrick; Klassen, Andreas; Dresing, Nina [Christian-Albrechts-Universitaet zu Kiel, 24118 Kiel (Germany); Gomez-Herrero, Raul [Universidad de Alcala (Spain)

    2016-07-01

    Ground Level Enhancements (GLEs) are solar energetic particle (SEP) events that are recorded by ground-based instrumentation. The energy of the particles is so high that they produce secondary particles in the Earth's atmosphere, i.e. protons and neutrons, which are detected as sudden increases in cosmic ray intensities measured by e.g. neutron monitors. Since the launch of SOHO in December 1995 the neutron monitor network recorded 16 GLEs. The Electron Proton Helium INstrument on board SOHO has been designed to measure protons and helium up to 53 MeV/nucleon as well as electrons up to 8.3 MeV. Above these energies, particles penetrate all detector elements and thus, a separation between different particle species becomes more complicated. Recently we developed a method that allows deriving the energy spectrum for penetrating protons up to more than 1 GeV. In this contribution we present the proton energy spectra and time profiles of above mentioned GLEs and compare them to previous measurements. Although there are differences of up to a factor two the overall shape of the energy spectra agree surprisingly well. Thus it has been demonstrated that EPHIN measurements are a valuable tool for understanding GLE.

  11. Measured Radiation and Background Levels During Transmission of Megawatt Electron Beams Through Millimeter Apertures

    Energy Technology Data Exchange (ETDEWEB)

    Alarcon, Ricardo [Arizona State University, Glendale, AZ (United States); Balascuta, S. [Arizona State University, Glendale, AZ (United States); Benson, Stephen V. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Bertozzi, William [Massachusetts Institute of Technology, Cambridge, MA (United States); Boyce, James R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Cowan, Ray [Massachusetts Institute of Technology, Cambridge, MA (United States); Douglas, David R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Evtushenko, Pavel [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Fisher, P. [Massachusetts Institute of Technology, Cambridge, MA (United States); Ihloff, Ernest E. [Hampton University, Hampton, VA (United States); Kalantarians, Narbe [Hampton University, Hampton, VA (United States); Kelleher, Aidan Michael [Massachusetts Institute of Technology, Cambridge, MA (United States); Krossler, W. J. [William and Mary College, Williamsburg, VA (United States); Legg, Robert A. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Long, Elena [University of New Hampshire, Durham, NH (United States); Milner, Richard [Massachusetts Institute of Technology, Cambridge, MA (United States); Neil, George R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Ou, Longwu [Massachusetts Institute of Technology, Cambridge, MA (United States); Schmookler, Barack Abraham [Massachusetts Institute of Technology, Cambridge, MA (United States); Tennant, Christopher D. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Tschalar, C. [Massachusetts Institute of Technology, Cambridge, MA (United States); Williams, Gwyn P. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Zhang, Shukui [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2013-11-01

    We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that need to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW continuous-wave (CW) beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, multipactoring inside the niobium cavities of the accelerator cryomodules is the primary source of ambient radiation when the machine is tuned for 130 MeV operation.

  12. Proton NMR for Measuring Quantum Level Crossing in the Magnetic Molecular Ring Fe10

    International Nuclear Information System (INIS)

    Julien, M.; Jang, Z.H.; Borsa, F.; Julien, M.; Lascialfari, A.; Borsa, F.; Horvatic, M.; Caneschi, A.; Gatteschi, D.

    1999-01-01

    The proton nuclear spin-lattice relaxation rate 1/T 1 has been measured as a function of temperature and magnetic field (up to 15thinspthinspT) in the molecular magnetic ring Fe 10 ( OCH 3 ) 20 (O 2 CCH 2 Cl) 10 (Fe10). Striking enhancement of 1/T 1 is observed around magnetic field values corresponding to a crossing between the ground state and the excited states of the molecule. We propose that this is due to a cross-relaxation effect between the nuclear Zeeman reservoir and the reservoir of the Zeeman levels of the molecule. This effect provides a powerful tool to investigate quantum dynamical phenomena at level crossing. copyright 1999 The American Physical Society

  13. Measuring the Return on Information Technology: A Knowledge-Based Approach for Revenue Allocation at the Process and Firm Level

    National Research Council Canada - National Science Library

    Pavlou, Paul A; Housel, Thomas J; Rodgers, Waymond; Jansen, Erik

    2005-01-01

    ...., firm or process level). To address this issue, the study aims to develop a method for allocating the revenue and cost of IT initiatives at any level of analysis using a common unit of measurement...

  14. Interlaboratory comparability of serum cotinine measurements at smoker and nonsmoker concentration levels: A round-robin study

    Science.gov (United States)

    Jacob, Peyton; Holiday, David B.; Benowitz, Neal L.; Sosnoff, Connie S.; Doig, Mira V.; Feyerabend, Colin; Aldous, Kenneth M.; Sharifi, Mehran; Kellogg, Mark D.; Langman, Loralie J.

    2009-01-01

    Introduction: Cotinine, the primary proximate metabolite of nicotine, is commonly measured as an index of exposure to tobacco in both active users of tobacco and nonsmokers with possible exposure to secondhand smoke (SHS). A number of laboratories have implemented analyses for measuring serum cotinine in recent years, but there have been few interlaboratory comparisons of the results. Among nonsmokers exposed to SHS, the concentration of cotinine in blood can be quite low, and extensive variability in these measurements has been reported in the past. Methods: In this study, a group of seven laboratories, all experienced in serum cotinine analysis, measured eight coded serum pools with concentrations ranging from background levels of about 0.05 ng/ml to relatively high concentrations in the active smokers range. All laboratories used either gas–liquid chromatography with nitrogen–phosphorus detection or liquid chromatography with mass spectrometric detection. Results: All seven laboratories reliably measured the cotinine concentrations in samples that were within the range of their methods. In each case, the results for the pools were correctly ranked in order, and no significant interlaboratory bias was observed at the 5% level of significance for results from any of the pools. Discussion: We conclude that present methods of chromatographic analysis of serum cotinine, as used by these experienced laboratories, are capable of providing accurate and precise results in both the smoker and the nonsmoker concentration range. PMID:19933777

  15. Vocabulary is an appropriate measure of premorbid intelligence in a sample with heterogeneous educational level in Brazil.

    Science.gov (United States)

    de Oliveira, Maira Okada; Nitrini, Ricardo; Yassuda, Mônica Sanches; Brucki, Sonia Maria Dozzi

    2014-01-01

    Crystallized intelligence refers to one's knowledge base and can be measured by vocabulary tests. Fluid intelligence is related to nonverbal aspects of intelligence, depends very little on previously acquired knowledge, and can be measured by tests such as Block Design (BD) and Raven Colored Matrices (RCM). Premorbid intelligence quotient (IQ) refers to one's intellectual ability level previous to the onset of disorders like mild cognitive impairment (MCI) and Alzheimer's disease (AD) and it is important to estimate disease severity. The objective was to compare performance in tests that measure crystallized and fluid intelligence in healthy subjects and patients with amnestic MCI (aMCI) and AD. One hundred forty-four participants (aMCI (n = 38), AD (n = 45), and healthy controls (n = 61)) were submitted to neuropsychological tests (WAIS-III vocabulary, BD, and RCM). There were significant among groups, except for vocabulary, indicating a relative stability of crystallized intelligence in the continuum from normal to pathological cognitive decline. Vocabulary seems to be stable during the progression of the disease and useful as a measure of premorbid intelligence, that is, to estimate previous function in relation to the level of education and, as a collateral measure of cognition in people with low education.

  16. Vocabulary Is an Appropriate Measure of Premorbid Intelligence in a Sample with Heterogeneous Educational Level in Brazil

    Directory of Open Access Journals (Sweden)

    Maira Okada de Oliveira

    2014-01-01

    Full Text Available Crystallized intelligence refers to one’s knowledge base and can be measured by vocabulary tests. Fluid intelligence is related to nonverbal aspects of intelligence, depends very little on previously acquired knowledge, and can be measured by tests such as Block Design (BD and Raven Colored Matrices (RCM. Premorbid intelligence quotient (IQ refers to one’s intellectual ability level previous to the onset of disorders like mild cognitive impairment (MCI and Alzheimer’s disease (AD and it is important to estimate disease severity. The objective was to compare performance in tests that measure crystallized and fluid intelligence in healthy subjects and patients with amnestic MCI (aMCI and AD. One hundred forty-four participants (aMCI (n=38, AD (n=45, and healthy controls (n=61 were submitted to neuropsychological tests (WAIS-III vocabulary, BD, and RCM. There were significant among groups, except for vocabulary, indicating a relative stability of crystallized intelligence in the continuum from normal to pathological cognitive decline. Vocabulary seems to be stable during the progression of the disease and useful as a measure of premorbid intelligence, that is, to estimate previous function in relation to the level of education and, as a collateral measure of cognition in people with low education.

  17. Impact of geographic area level on measuring socioeconomic disparities in cancer survival in New South Wales, Australia: A period analysis.

    Science.gov (United States)

    Stanbury, Julia F; Baade, Peter D; Yu, Yan; Yu, Xue Qin

    2016-08-01

    Area-based socioeconomic measures are widely used in health research. In theory, the larger the area used the more individual misclassification is introduced, thus biasing the association between such area level measures and health outcomes. In this study, we examined the socioeconomic disparities in cancer survival using two geographic area-based measures to see if the size of the area matters. We used population-based cancer registry data for patients diagnosed with one of 10 major cancers in New South Wales (NSW), Australia during 2004-2008. Patients were assigned index measures of socioeconomic status (SES) based on two area-level units, census Collection District (CD) and Local Government Area (LGA) of their address at diagnosis. Five-year relative survival was estimated using the period approach for patients alive during 2004-2008, for each socioeconomic quintile at each area-level for each cancer. Poisson-regression modelling was used to adjust for socioeconomic quintile, sex, age-group at diagnosis and disease stage at diagnosis. The relative excess risk of death (RER) by socioeconomic quintile derived from this modelling was compared between area-units. We found extensive disagreement in SES classification between CD and LGA levels across all socioeconomic quintiles, particularly for more disadvantaged groups. In general, more disadvantaged patients had significantly lower survival than the least disadvantaged group for both CD and LGA classifications. The socioeconomic survival disparities detected by CD classification were larger than those detected by LGA. Adjusted RER estimates by SES were similar for most cancers when measured at both area levels. We found that classifying patient SES by the widely used Australian geographic unit LGA results in underestimation of survival disparities for several cancers compared to when SES is classified at the geographically smaller CD level. Despite this, our RER of death estimates derived from these survival

  18. A Measurement Framework for Team Level Assessment of Innovation Capability in Early Requirements Engineering

    Science.gov (United States)

    Regnell, Björn; Höst, Martin; Nilsson, Fredrik; Bengtsson, Henrik

    When developing software-intensive products for a market-place it is important for a development organisation to create innovative features for coming releases in order to achieve advantage over competitors. This paper focuses on assessment of innovation capability at team level in relation to the requirements engineering that is taking place before the actual product development projects are decided, when new business models, technology opportunities and intellectual property rights are created and investigated through e.g. prototyping and concept development. The result is a measurement framework focusing on four areas: innovation elicitation, selection, impact and ways-of-working. For each area, candidate measurements were derived from interviews to be used as inspiration in the development of a tailored measurement program. The framework is based on interviews with participants of a software team with specific innovation responsibilities and validated through cross-case analysis and feedback from practitioners.

  19. Level Densities in the actinide region and indirect n,y cross section measurements using the surrogate method

    Directory of Open Access Journals (Sweden)

    Wiedeking M.

    2012-02-01

    Full Text Available Results from a program of measurements of level densities and gamma ray strength functions in the actinide region are presented. Experiments at the Oslo cyclotron involving the Cactus/Siri detectors and 232Th(d,x and 232Th(3He,x reactions were carried out to help answer the question of which level density model is the most appropriate for actinide nuclei, since it will have an impact on cross section calculations important for reactor physics simulations. A new technique for extracting level densities and gamma ray strength functions from particle-gamma coincidence data is proposed and results from the development of this technique are presented. In addition, simultaneous measurements of compound nuclear gamma decay probabilities have been performed for the key thorium cycle nuclei 233Th, 231Th and 232Pa up to around 1MeV above the neutron binding energy and have enabled extraction of indirect neutron induced capture cross sections for the 232Th, 231Pa and 230Th nuclei using the surrogate reaction method. Since the neutron capture cross section for 232Th is already well known from direct measurements a comparison provides a stringent test of the applicability of the surrogate technique in the actinide region.

  20. Vasopressin levels in plasma and urine of man, dogs and rats, as measured by radioimmunoassay, ch. 1

    International Nuclear Information System (INIS)

    Dogterom, J.; Buijs, R.M.; Wimersma Greidanus, Tj.B. van.

    1977-01-01

    A radioimmunoassay (RIA) of arginine-8-vasopressin (AVP) is reported. The production of antisera and labelled hormone is described. The antibodies are characterized with respect to their binding capacity, specificity and resulting sensitivity in the standard curves. An extraction procedure of AVP from body fluids appeared to be necessary and was performed with activated Vycor glass powder. Other adsorbents were tested as well. The results of the assay indicate that 0.5 pg AVP/ml plasma can be detected. The calculations of the data are fully automized using a Fortran IV programme for a digital computer. With this assay, basal AVP levels were measured in the plasma and urine of man, dogs and rats. In these species, plasma levels were in the range of 0.0-3.0 pg/ml. In addition, plasma AVP levels in rats and dogs were measured after different periods of water deprivation. In rats, AVP increase reached its maximum after 48 hrs of water deprivation: 27.1 +- 3.4 pg/ml

  1. Environmental radioactivity level and soil radon measurement of a volcanic region in Cameroon

    International Nuclear Information System (INIS)

    Ngachin, M.; Garavaglia, M.; Giovani, C.; Kwato Njock, M.G.

    2007-02-01

    A part of the survey programme on the evaluation of environmental radioactivity in Cameroon has just been initiated. The radioactivity level of soils in a volcanic area in Cameroon was determined and discussed. 30 soils samples were collected from Buea and Limbe cities located in the south-western Cameroon. These two regions are known for theirs volcanic grounds due to the presence of Mount Cameroon mountain. The activity concentrations of natural radionuclides as well as that of the fission product were evaluated by gamma-ray spectrometry using a hyper purity germanium detector (HPGe). The ranges of concentrations in the surveyed soils were 11 - 17 Bq kg -1 , 22 - 36 Bq kg -1 and 43 - 201 Bq kg -1 for 226 Ra, 232 Th and 40 K, respectively. The radioisotope 137 Cs was also found but in a very small amount. The outdoor absorbed dose rate 1 m above ground with the corresponding annual effective dose rate, assuming a 20% occupancy factor were estimated. The radium equivalent and the external hazard index were also evaluated and results are compared with available data from other studies and with the world average value (UNSCEAR, 1988, 2000). A solid state nuclear track detector (SSNTDs), LR-115 was used for soil radon measurements at a depth of 50 cm. The ranges of soil radon concentrations were 6.7 - 10.8 kBq m -3 and 5.5 - 8.7 kBq m -3 in Buea and Limbe, respectively. A positive correlation was found between concentrations of radium measured with γ-spectrometry and the soil radon concentrations measured with the nitrate cellulose detectors. The results of this study provide the radioactivity level in soil of a volcanic area, which has been found to be within the safety limits. The south-western Cameroon can be considered as having normal natural background radiation in normal living conditions. (author)

  2. Concentrations and size distributions of fine aerosol particles measured at roof level in urban zone

    Science.gov (United States)

    Despiau, S.; Croci, D.

    2007-05-01

    During the experimental Field Experiments to Constrain Models of Atmospheric Pollution and Transport of Emissions (ESCOMPTE) campaign in June-July 2001, concentrations and size distributions of fine particles (14-722 nm) were measured at roof level in downtown Marseille (France). Part of the campaign was dedicated to the study of aerosol behavior in relation to strong photochemical events (which were identified as "IOP" days) and their regional modeling. The analysis of the concentration variations and the evolution of average diurnal size distribution showed that an "IOP day" is not characterized by a specific concentration or its variation, nor by a specific evolution of the average size distribution. The morning traffic rush is detected at roof level by a net increase in particle concentration over the whole size range measured, indicating a production of ultrafine particles by the traffic but also the raising to roof level of particles of the accumulation mode. The increase is observed about 1 hour after the traffic peak at street level, which is characterized by strong increases in NOx and CO concentrations. The corresponding flux of particles at roof level has been estimated around 3 × 104 cm-2 s-1. A specific signature characterized by a strong and rapid burst of concentration (factor 2 to 4 in 15 min) of particles between 25 and 50 nm, independent of the traffic source, has been detected on six occasions during the campaign. These events occur systematically around noon, in cases of strong radiation, low relative humidity, and common wind direction. Despite the high-diameter value of these particles, it is suggested that they could result from a specific "secondary aerosol process" event involving ozone, biogenic, and/or anthropogenic gas precursors like iodine and VOCs.

  3. Quantification of birefringence readily measures the level of muscle damage in zebrafish

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Joachim, E-mail: Joachim.Berger@Monash.edu [Australian Regenerative Medicine Institute, EMBL Australia, Monash University, Clayton (Australia); Sztal, Tamar; Currie, Peter D. [Australian Regenerative Medicine Institute, EMBL Australia, Monash University, Clayton (Australia)

    2012-07-13

    Highlights: Black-Right-Pointing-Pointer Report of an unbiased quantification of the birefringence of muscle of fish larvae. Black-Right-Pointing-Pointer Quantification method readily identifies level of overall muscle damage. Black-Right-Pointing-Pointer Compare zebrafish muscle mutants for level of phenotype severity. Black-Right-Pointing-Pointer Proposed tool to survey treatments that aim to ameliorate muscular dystrophy. -- Abstract: Muscular dystrophies are a group of genetic disorders that progressively weaken and degenerate muscle. Many zebrafish models for human muscular dystrophies have been generated and analysed, including dystrophin-deficient zebrafish mutants dmd that model Duchenne Muscular Dystrophy. Under polarised light the zebrafish muscle can be detected as a bright area in an otherwise dark background. This light effect, called birefringence, results from the diffraction of polarised light through the pseudo-crystalline array of the muscle sarcomeres. Muscle damage, as seen in zebrafish models for muscular dystrophies, can readily be detected by a reduction in the birefringence. Therefore, birefringence is a very sensitive indicator of overall muscle integrity within larval zebrafish. Unbiased documentation of the birefringence followed by densitometric measurement enables the quantification of the birefringence of zebrafish larvae. Thereby, the overall level of muscle integrity can be detected, allowing the identification and categorisation of zebrafish muscle mutants. In addition, we propose that the establish protocol can be used to analyse treatments aimed at ameliorating dystrophic zebrafish models.

  4. Quantification of birefringence readily measures the level of muscle damage in zebrafish

    International Nuclear Information System (INIS)

    Berger, Joachim; Sztal, Tamar; Currie, Peter D.

    2012-01-01

    Highlights: ► Report of an unbiased quantification of the birefringence of muscle of fish larvae. ► Quantification method readily identifies level of overall muscle damage. ► Compare zebrafish muscle mutants for level of phenotype severity. ► Proposed tool to survey treatments that aim to ameliorate muscular dystrophy. -- Abstract: Muscular dystrophies are a group of genetic disorders that progressively weaken and degenerate muscle. Many zebrafish models for human muscular dystrophies have been generated and analysed, including dystrophin-deficient zebrafish mutants dmd that model Duchenne Muscular Dystrophy. Under polarised light the zebrafish muscle can be detected as a bright area in an otherwise dark background. This light effect, called birefringence, results from the diffraction of polarised light through the pseudo-crystalline array of the muscle sarcomeres. Muscle damage, as seen in zebrafish models for muscular dystrophies, can readily be detected by a reduction in the birefringence. Therefore, birefringence is a very sensitive indicator of overall muscle integrity within larval zebrafish. Unbiased documentation of the birefringence followed by densitometric measurement enables the quantification of the birefringence of zebrafish larvae. Thereby, the overall level of muscle integrity can be detected, allowing the identification and categorisation of zebrafish muscle mutants. In addition, we propose that the establish protocol can be used to analyse treatments aimed at ameliorating dystrophic zebrafish models.

  5. Continuous weeklong measurements of indoor particle levels in a Minnesota Tribal Casino Resort.

    Science.gov (United States)

    Zhou, Zheng; Bohac, David; Boyle, Raymond G

    2016-08-24

    Secondhand smoke (SHS) exposure for workers and patrons in hospitality venues is a persistent and significant public health concern. We designed this study to provide a comprehensive assessment of SHS exposure inside an Indian Tribal Casino in Minnesota. Real-time fine particulate matter (PM2.5) concentrations were measured at multiple locations for up to 7 days. The field monitoring provided information on the day of week and time of day variation of SHS exposure, as well as comparisons between smoking and non-smoking areas. Indoor PM2.5 level was nearly 13 times the concurrent outdoor PM2.5 level. Gaming floor hourly PM2.5 level was highest on Saturday night, averaged at 62.9 μg/m(3). Highest PM2.5 concentration was observed in smoking-permitted employee break room, reaching 600 μg/m(3). PM2.5 readings in non-smoking sections exhibited same temporal pattern as the readings in smoking sections. The results show that indoor concentration of PM2.5 is substantially higher than the outdoor level, posing health risks to casino workers and patrons. SHS can migrate into adjacent non-smoking areas very quickly. The casino's ventilation system did not fully eliminate SHS. A completely smoke-free casino would be the only way to fully protect non-smoking patrons and employees from the dangers of tobacco smoke.

  6. Measuring the Actual Levels and Patterns of Physical Activity/Inactivity of Adults with Intellectual Disabilities

    Science.gov (United States)

    Finlayson, Janet; Turner, Angela; Granat, Malcolm H.

    2011-01-01

    Background: Lack of regular physical activity is a significant risk to health. The aim of this study was to objectively measure the levels and patterns of activity of adults with intellectual disabilities, to inform the design of studies aimed at increasing activity and health in this population. Materials and Methods: Interviews were conducted…

  7. Measuring Light at Night and Melatonin Levels in Shift Workers: A Review of the Literature.

    Science.gov (United States)

    Hunter, Claudia M; Figueiro, Mariana G

    2017-07-01

    Shift work, especially that involving rotating and night shifts, is associated with an increased risk of diseases, including cancer. Attempts to explain the association between shift work and cancer in particular have focused on the processes of melatonin production and suppression. One hypothesis postulates that exposure to light at night (LAN) suppresses melatonin, whose production is known to slow the development of cancerous cells, while another proposes that circadian disruption associated with shift work, and not just LAN, increases health risks. This review focuses on six studies that employed quantitative measurement of LAN and melatonin levels to assess cancer risks in shift workers. These studies were identified via searching the PubMed database for peer-reviewed, English-language articles examining the links between shift work, LAN, and disease using the terms light at night, circadian disruption, health, risk, cancer, shift work, or rotating shift. While the results indicate a growing consensus on the relationship between disease risks (particularly cancer) and circadian disruption associated with shift work, the establishment of a direct link between LAN and disease has been impeded by contradictory studies and a lack of consistent, quantitative methods for measuring LAN in the research to date. Better protocols for assessing personal LAN exposure are required, particularly those employing calibrated devices that measure and sample exposure to workplace light conditions, to accurately assess LAN's effects on the circadian system and disease. Other methodologies, such as measuring circadian disruption and melatonin levels in the field, may also help to resolve discrepancies in the findings.

  8. Convenient telemetry system for precise and continuous measurement of groundwater level and temperature

    Energy Technology Data Exchange (ETDEWEB)

    Tsunakawa, Hideo; Asada, Toshi

    1988-03-25

    A telemeter system has been developed, a device easy to manufacture and install and which facilitates data collection and achieves a relative precision to at least 1 cm in underground water level and 5 m deg C in underground water temperature, thus contributing to earthquake prediction. Its underground water level sensor feeds as voltage the differential pressure of a membrane to which a semiconductor sensor chip is attached. The sensor uses a 12V DC power supply and achieves a sensitivity of 8 mV/cm to sense a 0-5 m water level change as a 1-5 V voltage fluctuation. This sensor is put into a 40 mm-diameter, 100 mm-long brass container and dipped in water at a depth of about 2.5 m. To detect underground water temperature sensor, a semiconductor sensor LM35 is placed in a 25 mm-diameter, 50 mm-long brass container and submerged at a desired depth. The system uses a 12-bit data logger. Telemetry takes place at 1,200 bps via modems and NTT's(Nippon Telegraph and Telecommunications) public telephone line. An example of measurement is shown and mentioned. (2 figs, 5 refs)

  9. A School-Level Proxy Measure for Individual-level Poverty Using School-Level Eligibility for Free and Reduced-Price Meals

    Science.gov (United States)

    Day, Sophia E.; Hinterland, Kinjia; Myers, Christa; Gupta, Leena; Harris, Tiffany G.; Konty, Kevin J.

    2016-01-01

    Background: Socioeconomic status (SES) impacts health outcomes. The Youth Risk Behavior Survey (YRBS), like many school-based data sources, lacks individual-level poverty information. We propose using school-level percentages of student eligibility for free/reduced-price meals (%FRPM) as a proxy for individual-level poverty. Methods: Using the New…

  10. The effect of repeated measurements and working memory on the most comfortable level in the ANL test.

    Science.gov (United States)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas; Kastberg, Tobias; Ibertsson, Tina

    2014-11-01

    To study the effect of a large number of repetitions on the most comfortable level (MCL) when doing the acceptable noise level (ANL) test, and explore if MCL variability is related to central cognitive processes. Twelve MCL repetitions were measured within the ANL test using interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. Thirty-two normal-hearing adults. Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used to assess the repeatability. Repeated measures ANOVA and CR indicated poor agreement between the two first repetitions. After excluding the first repetition, analyses showed that the MCL in the ANL test is reliable. A negative association was found between PWM and MCL variability indicating that subjects with higher PWM show less variability. The findings suggest that, after excluding the first repetition, the MCL in the ANL test is reliable. A single repetition of the MCL in the ANL test should be avoided. If an interleaved methodology is used, a single ANL repetition should be added prior to the actual testing. The findings also suggest that MCL variability is associated to PWM but not VSWM.

  11. Looking Under the Streetlight? A Framework for Differentiating Performance Measures by Level of Care in a Value-Based Payment Environment.

    Science.gov (United States)

    Naessens, James M; Van Such, Monica B; Nesse, Robert E; Dilling, James A; Swensen, Stephen J; Thompson, Kristine M; Orlowski, Janis M; Santrach, Paula J

    2017-07-01

    The majority of quality measures used to assess providers and hospitals are based on easily obtained data, focused on a few dimensions of quality, and developed mainly for primary/community care and population health. While this approach supports efforts focused on addressing the triple aim of health care, many current quality report cards and assessments do not reflect the breadth or complexity of many referral center practices.In this article, the authors highlight the differences between population health efforts and referral care and address issues related to value measurement and performance assessment. They discuss why measures may need to differ across the three levels of care (primary/community care, secondary care, complex care) and illustrate the need for further risk adjustment to eliminate referral bias.With continued movement toward value-based purchasing, performance measures and reimbursement schemes need to reflect the increased level of intensity required to provide complex care. The authors propose a framework to operationalize value measurement and payment for specialty care, and they make specific recommendations to improve performance measurement for complex patients. Implementing such a framework to differentiate performance measures by level of care involves coordinated efforts to change both policy and operational platforms. An essential component of this framework is a new model that defines the characteristics of patients who require complex care and standardizes metrics that incorporate those definitions.

  12. Air radioactivity levels following the Fukushima reactor accident measured at the Laboratoire Souterrain de Modane, France.

    Science.gov (United States)

    Loaiza, P; Brudanin, V; Piquemal, F; Reyss, J-L; Stekl, I; Warot, G; Zampaolo, M

    2012-12-01

    The radioactivity levels in the air of the radionuclides released by the Fukushima accident were measured at the Laboratoire Souterrain de Modane, in the South-East of France, during the period 25 March-18 April 2011. Air-filters from the ventilation system exposed for one or two days were measured using low-background gamma-ray spectrometry. In this paper we present the activity concentrations obtained for the radionuclides (131)I, (132)Te, (134)Cs, (137)Cs, (95)Nb, (95)Zr, (106)Ru, (140)Ba/La and (103)Ru. The activity concentration of (131)I was of the order of 100 μBq/m(3), more than 100 times higher than the activities of other fission products. The highest activities of (131)I were measured as a first peak on 30 March and a second peak on 3-4 April. The activity concentrations of (134)Cs and (137)Cs varied from 5 to 30 μBq/m(3). The highest activity concentration recorded for Cs corresponded to the same period as for (131)I, with a peak on 2-3 April. The results of the radioactivity concentration levels in grass and mushrooms exposed to the air in the Modane region were also measured. Activity concentrations of (131)I of about 100 mBq/m(2) were found in grass. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. New method of radiation measurement at carbon isotope 14 low level in an environmental atmospheric sampling

    International Nuclear Information System (INIS)

    Tormos, J.

    2009-01-01

    A new method of preparation is proposed to extract the atmospheric carbon trapped in the solution of soda coming from air sampling in environment with a carbon-14 bubbler (type H.A.G. 7000). It is based on the neutralisation of the global soda solution got from bubbling pots by nitric acid, the complete desorption of the carbon under gaseous oxidized form (CO 2 ) and its trapping in a only capacity containing a reactive. The whole of the device is scanned by air at steady rate. A test catch of the reactive and of the trapped carbon dioxide is then blended to a glistening liquid (Permafluor E+) and measured in beta counting by scintillation in liquid medium with a counter for the measurement of low energy beta emitters at very low level of activity (Quantulus type). this method allows to get a limit of detection equal to 5 mBq/m 3 for the atmospheric organic carbon. The principal interest of this method is its quickness and simplicity of setting in motion for a measurement of 14 C in the atmospheric carbon dioxide at a level of natural activity. (N.C.)

  14. A simplified method for low-level tritium measurement in the environmental water samples

    International Nuclear Information System (INIS)

    Sakuma, Yoichi; Yamanishi, Hirokuni; Ogata, Yoshimune

    2004-01-01

    Low level liquid scintillation counting took much time with a lot of doing to distill off the impurities in the sample water before mixing the sample with the liquid scintillation cocktail. In the light of it, we investigated the possibility of an alternative filtration method for sample purification. The tritium concentration in the environmental water has become very low, and the samples have to be treated by electrolysis enrichment with a liquid scintillation analyzer. Using the solid polymer electrolyte enriching device, there is no need to add neither any electrolyte nor the neutralization after the concentration. If we could replace the distillation process with the filtration, the procedure would be simplified very much. We investigated the procedure and we were able to prove that the reverse osmosis (RO) filtration was available. Moreover, in order to rationalize all through the measurement method, we examined the followings: (1) Improvement of the enriching apparatus. (2) Easier measurement of heavy water concentration using a density meter, instead of a mass spectrometer. The concentration of water samples was measured to determine the enrichment rate of tritium during the electrolysis enrichment. (author)

  15. Radioactivity level and soil radon measurement of a volcanic area in Cameroon

    Energy Technology Data Exchange (ETDEWEB)

    Ngachin, M. [Center for Atomic, Molecular Physics and Quantum Optics, University of Douala, P.O. Box 8580, Douala (Cameroon); Abdus Salam International Center for Theoretical Physics, Strada Costiera 11, 34014 Trieste (Italy); Institut Pluridisciplinaire Hubert-Curien, UMR7178 CNRS-IN2P3 and Universite Louis Pasteur, 23 rue de Loess, BP 28, F-67037 Strasbourg cedex 02 (France)], E-mail: mngachin@yahoo.com; Garavaglia, M.; Giovani, C. [Regional Agency for Environmental Protection (ARPA), 91 via Tavagnacco, 33100 Udine (Italy); Kwato Njock, M.G. [Center for Atomic, Molecular Physics and Quantum Optics, University of Douala, P.O. Box 8580, Douala (Cameroon); Nourreddine, A. [Institut Pluridisciplinaire Hubert-Curien, UMR7178 CNRS-IN2P3 and Universite Louis Pasteur, 23 rue de Loess, BP 28, F-67037 Strasbourg cedex 02 (France)

    2008-07-15

    The radioactivity level of soils in a volcanic area in Cameroon was determined and discussed. Thirty soils samples were collected from Buea and Limbe cities located in the south-western Cameroon. These two regions are known for theirs volcanic grounds due to the presence of Mount Cameroon Mountain. The activity concentrations of natural radionuclides as well as that of the fission product were evaluated by gamma-ray spectrometry using a hyper-purity germanium detector (HPGe). The ranges of concentrations in the surveyed soils were 11-17 Bq kg{sup -1}, 22-36 Bq kg{sup -1} and 43-201 Bq kg{sup -1} for {sup 226}Ra, {sup 232}Th and {sup 40}K, respectively. The radioisotope {sup 137}Cs was also found but in a very small amount. The outdoor absorbed dose rate 1 m above ground with the corresponding annual effective dose rate, assuming a 20% occupancy factor was estimated. The radium equivalent and the external hazard index were also evaluated and results are compared with available data from other studies and with the world average value [United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), 1988. Sources, Effects and Risks of Ionizing Radiation. Report to the General Assembly on the Effects of Atomic Radiation. United Nations, New York; UNSCEAR, 2000. Sources and Effects of Ionizing Radiations. Report to the General Assembly with Scientific Annexes. United Nations, New York]. A solid state nuclear track detector (SSNTD), LR-115 was used for soil radon measurements at a depth of 50 cm. The ranges of soil radon concentrations were 6.7-10.8 kBq m{sup -3} and 5.5-8.7 kBq m{sup -3} in Buea and Limbe, respectively. A positive correlation was found between concentrations of radium measured with {gamma}-spectrometry and the soil radon concentrations measured with the nitrate cellulose detectors. The results of this study provide the radioactivity level in soil of a volcanic area, which has been found to be within the safety limits. The south

  16. Reliability of smartphone-based gait measurements for quantification of physical activity/inactivity levels.

    Science.gov (United States)

    Ebara, Takeshi; Azuma, Ryohei; Shoji, Naoto; Matsukawa, Tsuyoshi; Yamada, Yasuyuki; Akiyama, Tomohiro; Kurihara, Takahiro; Yamada, Shota

    2017-11-25

    Objective measurements using built-in smartphone sensors that can measure physical activity/inactivity in daily working life have the potential to provide a new approach to assessing workers' health effects. The aim of this study was to elucidate the characteristics and reliability of built-in step counting sensors on smartphones for development of an easy-to-use objective measurement tool that can be applied in ergonomics or epidemiological research. To evaluate the reliability of step counting sensors embedded in seven major smartphone models, the 6-minute walk test was conducted and the following analyses of sensor precision and accuracy were performed: 1) relationship between actual step count and step count detected by sensors, 2) reliability between smartphones of the same model, and 3) false detection rates when sitting during office work, while riding the subway, and driving. On five of the seven models, the inter-class correlations coefficient (ICC (3,1) ) showed high reliability with a range of 0.956-0.993. The other two models, however, had ranges of 0.443-0.504 and the relative error ratios of the sensor-detected step count to the actual step count were ±48.7%-49.4%. The level of agreement between the same models was ICC (3,1) : 0.992-0.998. The false detection rates differed between the sitting conditions. These results suggest the need for appropriate regulation of step counts measured by sensors, through means such as correction or calibration with a predictive model formula, in order to obtain the highly reliable measurement results that are sought in scientific investigation.

  17. Continuous weeklong measurements of indoor particle levels in a Minnesota Tribal Casino Resort

    Directory of Open Access Journals (Sweden)

    Zheng Zhou

    2016-08-01

    Full Text Available Abstract Background Secondhand smoke (SHS exposure for workers and patrons in hospitality venues is a persistent and significant public health concern. We designed this study to provide a comprehensive assessment of SHS exposure inside an Indian Tribal Casino in Minnesota. Methods Real-time fine particulate matter (PM2.5 concentrations were measured at multiple locations for up to 7 days. The field monitoring provided information on the day of week and time of day variation of SHS exposure, as well as comparisons between smoking and non-smoking areas. Results Indoor PM2.5 level was nearly 13 times the concurrent outdoor PM2.5 level. Gaming floor hourly PM2.5 level was highest on Saturday night, averaged at 62.9 μg/m3. Highest PM2.5 concentration was observed in smoking-permitted employee break room, reaching 600 μg/m3. PM2.5 readings in non-smoking sections exhibited same temporal pattern as the readings in smoking sections. Conclusions The results show that indoor concentration of PM2.5 is substantially higher than the outdoor level, posing health risks to casino workers and patrons. SHS can migrate into adjacent non-smoking areas very quickly. The casino’s ventilation system did not fully eliminate SHS. A completely smoke-free casino would be the only way to fully protect non-smoking patrons and employees from the dangers of tobacco smoke.

  18. Extreme groundwater levels caused by extreme weather conditions - the highest ever measured groundwater levels in Middle Germany and their management

    Science.gov (United States)

    Reinstorf, F.; Kramer, S.; Koch, T.; Pfützner, B.

    2017-12-01

    Extreme weather conditions during the years 2009 - 2011 in combination with changes in the regional water management led to maximum groundwater levels in large areas of Germany in 2011. This resulted in extensive water logging, with problems especially in urban areas near rivers, where water logging produced huge problems for buildings and infrastructure. The acute situation still exists in many areas and requires the development of solution concepts. Taken the example of the Elbe-Saale-Region in the Federal State of Saxony-Anhalt, were a pilot research project was carried out, the analytical situation, the development of a management tool and the implementation of a groundwater management concept are shown. The central tool is a coupled water budget - groundwater flow model. In combination with sophisticated multi-scale parameter estimation, a high-resolution groundwater level simulation was carried out. A decision support process with an intensive stakeholder interaction combined with high-resolution simulations enables the development of a management concept for extreme groundwater situations in consideration of sustainable and environmentally sound solutions mainly on the base of passive measures.

  19. Measurements of vertebral shape by radiographic morphometry: sex differences and relationships with vertebral level and lumbar lordosis

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, X G; Sun, Y; Boonen, S; Nicholson, P H.F.; Dequeker, J [Arthritis and Metabolic Bone Disease Research Unit, U.Z. Pellenberg, Division of Rheumatology, Pellenberg (Belgium); Brys, P [Radiology Department, University Hospitals, Katholieke Universiteit Leuven, Leuven (Belgium); Felsenberg, D [Radiology Department, Freie Univ. Berlin (Germany)

    1998-07-01

    Objective. To examine sex-related and vertebral-level-specific differences in vertebral shape and to investigate the relationships between the lumbar lordosis angle and vertebral morphology. Design and patients. Lateral thoracic and lumbar spine radiographs were obtained with a standardized protocol in 142 healthy men and 198 healthy women over 50 years old. Anterior (Ha), central (Hc) and posterior (Hp) heights of each vertebra from T4 to L4 were measured using a digitizing technique, and the Ha/Hp and Hc/Hp ratios were calculated. The lumbar lordosis angle was measured on the lateral lumbar spine radiographs. Results. Ha/Hp and Hc/Hp ratios were smaller in men than women by 1.8% and 0.7%, respectively, and these ratios varied with vertebral level. Significant correlations were found between vertebral shape and the lumbar lordosis angle. Conclusions. These results demonstrate that vertebral shape varies significantly with sex, vertebral level and lumbar lordosis angle. Awareness of these relationships may help prevent misdiagnosis in clinical vertebral morphometry. (orig.) With 4 figs., 2 tabs., 17 refs.

  20. Fit-To-Fight: Waist vs Waist/Height Measurements to Determine an Individual's Fitness Level - A Study in Statistical Regression and Analysis

    National Research Council Canada - National Science Library

    Swiderski, Steven J

    2005-01-01

    .... The abdominal measurement is a "one-size-fits-all" fitness standard. This research determines that a person's waist-to-height ratio is a better measurement than the waist measurement to estimate an individual's fitness level...

  1. Relative level populations in S VI after beam-foil excitation, obtained from ANDC analyses of measured decay curves

    International Nuclear Information System (INIS)

    Engstroem, L.

    1983-01-01

    This paper reports the relative population of the levels 3p, 3d, 4d, 5d, 4f, 5g, 6g, 6h, 7h, 7i, 8i and 8k in Na-like sulfur, S VI, after beam-foil excitation at an energy of 3 MeV. For the first time the ANDC technique has been used to obtain the relative efficiency calibration of the detection system at discrete points in the wavelength interval 400-5000 A, from the analyses of measured decay curves. The advantages and limitations of this method are discussed. The populations obtained with this new technique are compared to previous measurements in multiply ionized atoms. The preferential population of the 3p and 3d levels observed in other Na-like ions is now accurately established. For the higher lying levels an almost constant population is observed. (Auth.)

  2. Ionization Spectroscopic Measurement of nP Rydberg Levels of 87Rb Cold Atoms

    Science.gov (United States)

    Li, Yufan; Zaheeruddin, Syed; Zhao, Dongmei; Ma, Xinwen; Yang, Jie

    2018-05-01

    We created an ultracold plasma via the spontaneous ionization of cold dense Rydberg atoms of 87Rb in a magneto-optical trap (MOT), and measured the nS1/2 (n = 50-80), nP1/2 (n = 16-23), nP3/2 (n = 16-98), and nD5/2 (n = 49-96) Rydberg levels by detecting the electrons in the ultracold plasma. By fitting the energy levels of Rydberg states, the first ionization potential of 33690.950(11) cm-1 and the quantum defects of S, P, and D orbitals were obtained. The absolute transition energies of nS1/2 (n = 66-80), nP1/2 (n = 16-23), nP3/2 (n = 16-98), and nD5/2 (n = 58-96) states of 87Rb, as well as the quantum defects for p1/2 and p3/2 series, are given for the first time.

  3. Exploratory Analysis of Carbon Dioxide Levels, Ultrasound and Optical Coherence Tomography Measures of the Eye During ISS Missions

    Science.gov (United States)

    Schaefer, C.; Coble, C.; Mason, S.; Young, M.; Wear, M. L.; Sargsyan, A.; Garcia, K.; Patel, N.; Gibson, C.; Alexander, D.; hide

    2017-01-01

    Carbon dioxide (CO2) levels on board the International Space Station (ISS) have typically averaged 2.3 to 5.3 mmHg, with large fluctuations occurring over periods of hours and days. CO2 has effects on cerebral vascular tone, resulting in vasodilation and alteration of cerebral blood flow (CBF). Increased CBF leads to elevated intracranial pressure (ICP), a factor leading to visual disturbances, headaches, and other central nervous system symptoms. Ultrasound of the optic nerve and optical coherence tomography (OCT) provide surrogate measurements of ICP; in-flight measurements of both were implemented as enhanced screening tools for the Visual Impairment/Intracranial Pressure (VIIP) syndrome. This analysis examines the relationships between ambient CO2 levels on ISS, ultrasound and OCT measures of the eye in an effort to understand how CO2 may possibly be associated with VIIP and to inform future analysis of in-flight VIIP data.

  4. 'Becquerel screening' device to automatically measure activity level of contaminated soil in flexible containers

    International Nuclear Information System (INIS)

    Okada, Hisashi; Yamaguchi, Yoshihisa; Yamamoto, Shuji

    2014-01-01

    Contaminated soil and incineration ash collected during offsite decontamination work following the accident at the Fukushima Daiichi Nuclear Power Station of Tokyo Electric Power Co., Inc. is being stored in flexible containers. These containers are managed taking their activity level into account in accordance with the Decontamination Guidelines issued by the Ministry of the Environment. Toshiba has developed the 'Becquerel Screening' device that can automatically measure the activity level of the contents of each flexible container simply by placing the container on a palette, without the need to take samples for analysis from the container. The Becquerel Screening device is expected to contribute not only to improved operational efficiency but also to reduced exposure of operators to radiation, because it eliminates the need for direct contact with contaminated soil and ash. (author)

  5. Low-level violence in schools: is there an association between school safety measures and peer victimization?

    Science.gov (United States)

    Blosnich, John; Bossarte, Robert

    2011-02-01

    Low-level violent behavior, particularly school bullying, remains a critical public health issue that has been associated with negative mental and physical health outcomes. School-based prevention programs, while a valuable line of defense to stave off bullying, have shown inconsistent results in terms of decreasing bullying. This study explored whether school safety measures (eg, security guards, cameras, ID badges) were associated with student reports of different forms of peer victimization related to bullying. Data came from the 2007 School Crime Supplement of the National Crime Victimization Survey. Chi-square tests of independence were used to examine differences among categorical variables. Logistic regression models were constructed for the peer victimization outcomes. A count variable was constructed among the bullying outcomes (0-7) with which a Poisson regression model was constructed to analyze school safety measures' impacts on degree of victimization. Of the various school safety measures, only having adults in hallways resulted in a significant reduction in odds of being physically bullied, having property vandalized, or having rumors spread. In terms of degree of victimization, having adults and/or staff supervising hallways was associated with an approximate 26% decrease in students experiencing an additional form of peer victimization. Results indicated that school safety measures overall were not associated with decreased reports of low-level violent behaviors related to bullying. More research is needed to further explore what best promotes comprehensive safety in schools. © 2011, American School Health Association.

  6. Hollow optical-fiber based infrared spectroscopy for measurement of blood glucose level by using multi-reflection prism.

    Science.gov (United States)

    Kino, Saiko; Omori, Suguru; Katagiri, Takashi; Matsuura, Yuji

    2016-02-01

    A mid-infrared attenuated total reflection (ATR) spectroscopy system employing hollow optical fibers and a trapezoidal multi-reflection ATR prism has been developed to measure blood glucose levels. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. An analysis of in vivo measurements of human inner lip mucosa revealed clear signatures of glucose in the difference spectra between ones taken during the fasting state and ones taken after ingestion of glucose solutions. A calibration plot based on the absorption peak at 1155 cm(-1) that originates from the pyranose ring structure of glucose gave measurement errors less than 20%.

  7. LOFT liquid level transducer application techniques and measurement uncertainty

    International Nuclear Information System (INIS)

    Batt, D.L.; Biladeau, G.L.; Goodrich, L.D.; Nightingale, C.M.

    1979-01-01

    A conductivity sensitive liquid level transducer (LLT) has been designed and used successfully for determining whether steam or water is present in the Loss-of-Fluid Tests (LOFT) performed by EG and G Idaho, Inc., at the Idaho National Engineering Laboratory. The presence of steam or water is determined by establishing a discriminator level which is set manually. A computer program establishes the presence or absence of water for each data point taken. In addition to liquid level, the LLT is used for reactor vessel mass and volume calculations. The uncertainty in the liquid level is essentially the spacing of the LLT electrodes

  8. Lifetime measurements of odd-parity high-excitation levels of Sn I by time-resolved laser spectroscopy

    International Nuclear Information System (INIS)

    Zhang, Wei; Feng, Yanyan; Xu, Jiaxin; Dai, Zhenwen; Palmeri, Patrick; Quinet, Pascal; Biemont, Emile

    2010-01-01

    Natural radiative lifetimes of 38 odd-parity highly excited levels in neutral tin in the energy range from 43 682.737 to 56 838.68 cm -1 have been measured by a time-resolved laser-induced fluorescence technique in an atomic beam produced by laser ablation on a solid tin sample. All the levels were excited from the metastable 3 P 1, 2 and 1 D 2 levels in the ground configuration. The second and third harmonics of a dye laser were adopted as the tunable exciting source (207-250 nm). The lifetime results obtained in this paper are in the range from 4.6 to 292 ns and will be useful in extending the set of oscillator strengths available in Sn I.

  9. Effects of Goal Line Feedback on Level, Slope, and Stability of Performance within Curriculum-Based Measurement.

    Science.gov (United States)

    Fuchs, Lynn S.; And Others

    1991-01-01

    Nineteen special educators implemented Curriculum-Based Measurement with a total of 36 learning-disabled math pupils in grades 2-8 to examine the effects of goal line feedback. Results indicated comparable levels and slopes of student performance across treatment conditions, although goal line feedback was associated with greater performance…

  10. Development of a high-sensitivity and portable cell using Helmholtz resonance for noninvasive blood glucose-level measurement based on photoacoustic spectroscopy.

    Science.gov (United States)

    Tachibana, K; Okada, K; Kobayashi, R; Ishihara, Y

    2016-08-01

    We describe the possibility of high-sensitivity noninvasive blood glucose measurement based on photoacoustic spectroscopy (PAS). The demand for noninvasive blood glucose-level measurement has increased due to the explosive increase in diabetic patients. We have developed a noninvasive blood glucose-level measurement based on PAS. The conventional method uses a straight-type resonant cell. However, the cell volume is large, which results in a low detection sensitivity and difficult portability. In this paper, a small-sized Helmholtz-type resonant cell is proposed to improve detection sensitivity and portability by reducing the cell dead volume. First, the acoustic property of the small-sized Helmholtz-type resonant cell was evaluated by performing an experiment using a silicone rubber. As a result, the detection sensitivity of the small-sized Helmholtz-type resonant cell was approximately two times larger than that of the conventional straight-type resonant cell. In addition, the inside volume was approximately 30 times smaller. Second, the detection limits of glucose concentration were estimated by performing an experiment using glucose solutions. The experimental results showed that a glucose concentration of approximately 1% was detected by the small-sized Helmholtz-type resonant cell. Although these results on the sensitivity of blood glucose-level measurement are currently insufficient, they suggest that miniaturization of a resonance cell is effective in the application of noninvasive blood glucose-level measurement.

  11. Computerized system to measure interproximal alveolar bone levels in epidemiologic, radiographic investigations. II. Intra- and inter-examinar variation study

    Energy Technology Data Exchange (ETDEWEB)

    Wouters, F.R.; Frithiof, L.; Soeder, P.Oe.; Hellden, L.; Lavstedt, S.; Salonen, L.

    1988-01-01

    The study was aimed at analyzing intra- and inter-examiner variations in computerized measurement and in non-measurability of alveolar bone level in a cross-sectional, epidemiologic material. At each interproximal tooth surface, alveolar bone height in percentage of root length (B/R) and tooth length (B/T) were determined twice by one examiner and once by a second examiner from X5-magnified periapical radiographs. The overall intra- and inter-examiner variations in measurement were 2.85% and 3.84% of root length and 1.97% and 2.82% of tooth length, respectively. The varations were different for different tooth groups and for different degrees of severity of marginal periodontitis. The overall proportions on non-measurable tooth surfaces varied with examiner from 32% to 39% and from 43% to 48% of the available interproximal tooth surfaces for B/R and B/T, respectively. With regard to the level of reliability, the computerized method reported is appropriate to cross-sectional, epidemiologic investigations from radiographs.

  12. Search for buildings with high radon levels in Sweden: measurements carried out by local authorities in both older and newly built homes

    International Nuclear Information System (INIS)

    Swedjemark, G.A.

    1988-01-01

    Local authorities in Sweden have made about 58,000 radon daughter measurements with the following aims: (1) to search for houses with high radon daughter levels, (2) to determine the level above which the house would be regarded as an insanitary dwelling, and (3) to check that the radon daughter concentrations in newly built houses are below the established limit. The sampling of dwellings is therefore not representative for Swedish homes. 5300 homes were found to have levels above the limit 400 Bq.m -3 EER. The highest level found was 28,000 Bq.m -3 . In about one third of the homes found to have levels exceeding the limit, measures had been carried out to decrease the radon daughter concentration. About half of the homes in which the levels were decreased had levels below the limit for rebuilding, e.g. 200 Bq.m -3 . Measurements in order to ascertain levels in newly built houses were made in about 1100 homes out of 200,000 built since 1981 which was the year in which requirements for newly built houses came into force. Of those built with radon-protective foundations, 94% had concentrations below the 70 Bq.m -3 EER limit, compared to 80% for traditional building techniques. (author)

  13. Temperature and level measurements realized for Nuclear Safety Level Improvement of Slovak NPPs

    International Nuclear Information System (INIS)

    Badiar, S.; Slanina, M.; Stanc, S.; Golan, P.; Krupa, J.

    2001-01-01

    Process of continual safety improvement in the individual Slovak nuclear power plants has been in progress since the beginning of nineties with the objective to upgrade the safety level of units in operation up to the European standards. In the framework of these activities, safety instrumentation systems with 1E qualification for the control of WWER reactor coolant systems were built and added. Methods for implementation of safety instrumentation systems for monitoring temperature and level in reactor coolant systems in the particular plants in Slovakia are presented showing the objectives and methods of their implementation. (Authors)

  14. ASRDI oxygen technology survey. Volume 5: Density and liquid level measurement instrumentation for the cryogenic fluids oxygen, hydrogen, and nitrogen

    Science.gov (United States)

    Roder, H. M.

    1974-01-01

    Information is presented on instrumentation for density measurement, liquid level measurement, quantity gauging, and phase measurement. Coverage of existing information directly concerned with oxygen was given primary emphasis. A description of the physical principle of measurement for each instrumentation type is included. The basic materials of construction are listed if available from the source document for each instrument discussed. Cleaning requirements, procedures, and verification techniques are included.

  15. Higher measured than modeled ozone production at increased NOx levels in the Colorado Front Range

    Directory of Open Access Journals (Sweden)

    B. C. Baier

    2017-09-01

    Full Text Available Chemical models must correctly calculate the ozone formation rate, P(O3, to accurately predict ozone levels and to test mitigation strategies. However, air quality models can have large uncertainties in P(O3 calculations, which can create uncertainties in ozone forecasts, especially during the summertime when P(O3 is high. One way to test mechanisms is to compare modeled P(O3 to direct measurements. During summer 2014, the Measurement of Ozone Production Sensor (MOPS directly measured net P(O3 in Golden, CO, approximately 25 km west of Denver along the Colorado Front Range. Net P(O3 was compared to rates calculated by a photochemical box model that was constrained by measurements of other chemical species and that used a lumped chemical mechanism and a more explicit one. Median observed P(O3 was up to a factor of 2 higher than that modeled during early morning hours when nitric oxide (NO levels were high and was similar to modeled P(O3 for the rest of the day. While all interferences and offsets in this new method are not fully understood, simulations of these possible uncertainties cannot explain the observed P(O3 behavior. Modeled and measured P(O3 and peroxy radical (HO2 and RO2 discrepancies observed here are similar to those presented in prior studies. While a missing atmospheric organic peroxy radical source from volatile organic compounds co-emitted with NO could be one plausible solution to the P(O3 discrepancy, such a source has not been identified and does not fully explain the peroxy radical model–data mismatch. If the MOPS accurately depicts atmospheric P(O3, then these results would imply that P(O3 in Golden, CO, would be NOx-sensitive for more of the day than what is calculated by models, extending the NOx-sensitive P(O3 regime from the afternoon further into the morning. These results could affect ozone reduction strategies for the region surrounding Golden and possibly other areas that do not comply with national ozone

  16. Sea level: measuring the bounding surfaces of the ocean

    Science.gov (United States)

    Tamisiea, Mark E.; Hughes, Chris W.; Williams, Simon D. P.; Bingley, Richard M.

    2014-01-01

    The practical need to understand sea level along the coasts, such as for safe navigation given the spatially variable tides, has resulted in tide gauge observations having the distinction of being some of the longest instrumental ocean records. Archives of these records, along with geological constraints, have allowed us to identify the century-scale rise in global sea level. Additional data sources, particularly satellite altimetry missions, have helped us to better identify the rates and causes of sea-level rise and the mechanisms leading to spatial variability in the observed rates. Analysis of all of the data reveals the need for long-term and stable observation systems to assess accurately the regional changes as well as to improve our ability to estimate future changes in sea level. While information from many scientific disciplines is needed to understand sea-level change, this review focuses on contributions from geodesy and the role of the ocean's bounding surfaces: the sea surface and the Earth's crust. PMID:25157196

  17. Measuring Sea Level Rise-Induced Shoreline Changes and Inundation in Real Time

    Science.gov (United States)

    Shilling, F.; Waetjen, D.; Grijalva, E.

    2016-12-01

    We describe a method to monitor shoreline inundation and changes in response to sea level rise (SLR) using a network of time-lapse cameras. We found for coastal tidal marshes that this method was sensitive to vertical changes in sea level of 20 cm has occurred in the San Francisco Bay and other US coastal areas and is likely to rise by another 30-45 cm by mid-century, which will flood and erode many coastal ecosystems, highways, and urban areas. This rapid degree of rise means that it is imperative to co-plan for natural and built systems. Many public facilities are adjacent to shoreline ecosystems, which both protect infrastructure from wave and tide energy and are home to regulated species and habitats. Accurate and timely information about the actual extent of SLR impacts to shorelines will be critical during built-system adaptation. Currently, satellite-sourced imagery cannot provide the spatial or temporal resolution necessary to investigate fine-scale shoreline changes, leaving a gap between predictive models and knowing how, where and when these changes are occurring. The method described is feasible for near-term (1 to 10 years) to long-term application and can be used for measuring fine-resolution shoreline changes (organize photographs that could be combined with related external data (e.g., gauged water levels) to create an information mashup. This information could be used to validate models predicting shoreline inundation and loss, inform SLR-adaptation planning, and to visualize SLR impacts to the public.

  18. The Implementation Leadership Scale (ILS): development of a brief measure of unit level implementation leadership.

    Science.gov (United States)

    Aarons, Gregory A; Ehrhart, Mark G; Farahnak, Lauren R

    2014-04-14

    In healthcare and allied healthcare settings, leadership that supports effective implementation of evidenced-based practices (EBPs) is a critical concern. However, there are no empirically validated measures to assess implementation leadership. This paper describes the development, factor structure, and initial reliability and convergent and discriminant validity of a very brief measure of implementation leadership: the Implementation Leadership Scale (ILS). Participants were 459 mental health clinicians working in 93 different outpatient mental health programs in Southern California, USA. Initial item development was supported as part of a two United States National Institutes of Health (NIH) studies focused on developing implementation leadership training and implementation measure development. Clinician work group/team-level data were randomly assigned to be utilized for an exploratory factor analysis (n = 229; k = 46 teams) or for a confirmatory factor analysis (n = 230; k = 47 teams). The confirmatory factor analysis controlled for the multilevel, nested data structure. Reliability and validity analyses were then conducted with the full sample. The exploratory factor analysis resulted in a 12-item scale with four subscales representing proactive leadership, knowledgeable leadership, supportive leadership, and perseverant leadership. Confirmatory factor analysis supported an a priori higher order factor structure with subscales contributing to a single higher order implementation leadership factor. The scale demonstrated excellent internal consistency reliability as well as convergent and discriminant validity. The ILS is a brief and efficient measure of unit level leadership for EBP implementation. The availability of the ILS will allow researchers to assess strategic leadership for implementation in order to advance understanding of leadership as a predictor of organizational context for implementation. The ILS also holds promise as a tool for

  19. The implementation leadership scale (ILS): development of a brief measure of unit level implementation leadership

    Science.gov (United States)

    2014-01-01

    Background In healthcare and allied healthcare settings, leadership that supports effective implementation of evidenced-based practices (EBPs) is a critical concern. However, there are no empirically validated measures to assess implementation leadership. This paper describes the development, factor structure, and initial reliability and convergent and discriminant validity of a very brief measure of implementation leadership: the Implementation Leadership Scale (ILS). Methods Participants were 459 mental health clinicians working in 93 different outpatient mental health programs in Southern California, USA. Initial item development was supported as part of a two United States National Institutes of Health (NIH) studies focused on developing implementation leadership training and implementation measure development. Clinician work group/team-level data were randomly assigned to be utilized for an exploratory factor analysis (n = 229; k = 46 teams) or for a confirmatory factor analysis (n = 230; k = 47 teams). The confirmatory factor analysis controlled for the multilevel, nested data structure. Reliability and validity analyses were then conducted with the full sample. Results The exploratory factor analysis resulted in a 12-item scale with four subscales representing proactive leadership, knowledgeable leadership, supportive leadership, and perseverant leadership. Confirmatory factor analysis supported an a priori higher order factor structure with subscales contributing to a single higher order implementation leadership factor. The scale demonstrated excellent internal consistency reliability as well as convergent and discriminant validity. Conclusions The ILS is a brief and efficient measure of unit level leadership for EBP implementation. The availability of the ILS will allow researchers to assess strategic leadership for implementation in order to advance understanding of leadership as a predictor of organizational context for implementation

  20. Active Radiation Level Measurement on New Laboratory Instrument for Evaluating the Antibacterial Activity of Radioisotope

    International Nuclear Information System (INIS)

    Joh, Eunha; Park, Jang Guen

    2014-01-01

    A disc method has been widely used to measure the antibacterial effect of chemical agents. However, it is difficult to measure the antibacterial effect of radioisotopes using a disc method. A disc method is a method for diffusing a drug by placing the drug containing disc on the medium. In this method, radioisotopes are diffused on the medium and it is difficult to measure the exact effect by radiation. Thus, new laboratory equipment needs to evaluate the antibacterial activity by the radioisotopes. In this study, we measured the radiation level of radioisotopes on a new laboratory instrument using a MCNP. A disc method has been widely used to measure the antibacterial effect of chemical agents. This method uses a drug diffusion system for the measurement of anti-bacterial antibiotics. To measure the antimicrobial activity of a radioisotope, a new type of laboratory instrument is necessary to prevent the drug from spreading. The radioisotopes are used to diagnose and treat cancer. However, studies for anti-biotical use have not progressed. The radiation of radioisotopes has the effect of killing bacteria. Before this study proceeds further, it is necessary to be able to measure the antimicrobial activity of the radioisotope easily in the laboratory. However, in this study, it was possible to measure the antimicrobial activity of the radioisotope in the laboratory using a new laboratory instrument. We intend to start evaluation studies of the antibacterial activity of specific radioisotopes. In addition, it will be possible to develop research to overcome diseases caused by bacteria in the future

  1. Active Radiation Level Measurement on New Laboratory Instrument for Evaluating the Antibacterial Activity of Radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Joh, Eunha; Park, Jang Guen [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    A disc method has been widely used to measure the antibacterial effect of chemical agents. However, it is difficult to measure the antibacterial effect of radioisotopes using a disc method. A disc method is a method for diffusing a drug by placing the drug containing disc on the medium. In this method, radioisotopes are diffused on the medium and it is difficult to measure the exact effect by radiation. Thus, new laboratory equipment needs to evaluate the antibacterial activity by the radioisotopes. In this study, we measured the radiation level of radioisotopes on a new laboratory instrument using a MCNP. A disc method has been widely used to measure the antibacterial effect of chemical agents. This method uses a drug diffusion system for the measurement of anti-bacterial antibiotics. To measure the antimicrobial activity of a radioisotope, a new type of laboratory instrument is necessary to prevent the drug from spreading. The radioisotopes are used to diagnose and treat cancer. However, studies for anti-biotical use have not progressed. The radiation of radioisotopes has the effect of killing bacteria. Before this study proceeds further, it is necessary to be able to measure the antimicrobial activity of the radioisotope easily in the laboratory. However, in this study, it was possible to measure the antimicrobial activity of the radioisotope in the laboratory using a new laboratory instrument. We intend to start evaluation studies of the antibacterial activity of specific radioisotopes. In addition, it will be possible to develop research to overcome diseases caused by bacteria in the future.

  2. Limits to prediction of energy balance from milk composition measures at individual cow level

    DEFF Research Database (Denmark)

    Løvendahl, P; Ridder, C; Friggens, N C

    2010-01-01

    at each milking. Three breeds (Danish Red, Holstein-Friesian, and Jersey) of cows (299 cows, 623 lactations) in parities 1 to 4 were used. Milk data were smoothed using a rolling local regression. Energy balance based on milk composition was calculated using a partial least squares (PLS) model based......Frequently updated energy balance (EB) estimates for individual cows are especially useful for dairy herd management, and individual-level estimates form the basis for group-level EB estimates. The accuracy of EB estimates determines the value of this information for management decision support....... This study aimed to assess EB accuracy through ANOVA components and by comparing EB estimates based either on milk composition (EBalMilk) or on body condition score (BCS) and body weight (BW) (EBalBody). Energy balance based on milk composition was evaluated using data in which milk composition was measured...

  3. Level of Agreement Between Forearm and Upper Arm Blood Pressure Measurements in Patients With Large Arm Circumference.

    Science.gov (United States)

    Watson, Sheri; Aguas, Marita; Colegrove, Pat; Foisy, Nancy; Jondahl, Bonnie; Anastas, Zoe

    2017-02-01

    The purpose of the study was to determine if forearm blood pressures (BPs) measured in three different locations agree with the recommended upper arm location for noninvasive BP measurement. A method-comparison design was used. In a convenience sample of postanesthesia care unit patients with large upper arm circumference, BP's were obtained in three different forearm locations (lower forearm, middle forearm, and upper forearm) and compared to upper arm BP using an automated BP measuring device. The level of agreement (bias ± precision) between each forearm location and the upper arm BP was calculated using standard formulas. Acceptable levels of agreement based on expert opinion were set a priori at bias and precision values of less than ±5 mm Hg (bias) and ±8 mm Hg (precision). Forty-eight postanesthesia patients participated in the study. Bias and precision values were found to exceed the acceptable level of agreement for all but one of the systolic and diastolic BP comparisons in the three forearm BP locations. Fifty-six percent of all patients studied had one or more BP difference of at least 10 mm Hg in each of the three forearm locations, with 10% having one or more differences of at least 20 mm Hg. The differences in forearm BP measurements observed in this study indicate that the clinical practice of using a forearm BP with a regular-sized BP cuff in place of a larger sized BP cuff placed on the upper arm in postanesthesia care unit patients with large arm circumferences is inappropriate. The BPs obtained at the forearm location are not equivalent to the BPs obtained at the upper arm location. Copyright © 2015 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  4. Determination of deep levels in semi-insulating cadmium telluride by thermally stimulated current measurements

    International Nuclear Information System (INIS)

    Scharager, C.; Muller, J.C.; Stuck, R.; Siffert, P.

    1975-01-01

    Thermally stimulated current (TSC) measurements have been performed in high resistivity (rho approximately 10 7 ohms.cm) CdTe γ-ray detectors between 35 and 300K. The TSC curves have been analyzed by different methods, including those taking into account the retrapping of the carriers. The trap characteristics have been determined; especially three levels located at E(v)+0.13eV, E(v)+0.30eV and E(c)-0.55eV have been investigated [fr

  5. GOOD CORPORATE GOVERNANCE MECHANISMS IN MEASURING QUALITY OF FINANCIAL STATEMENTS AND TRANSFER INVESTOR LEVELS

    OpenAIRE

    Hani, Syafrida; UMSU, Hafsah

    2017-01-01

    ABSTRACTThis study aims to develop a theory of determining the quality of financial statement reports that can increase  investor  confidence  in  financial  information  presented  by management.  This  research would like to find the role of good corporate governance  in improving the quality of financial statements as measured by accounting conservatism and earnings management, then it will be seen how the quality ability of financial statement can influence investor confidence level. The ...

  6. Effects of brief smoking cessation education with expiratory carbon monoxide measurement on level of motivation to quit smoking.

    Science.gov (United States)

    Choi, Won-Young; Kim, Cheol-Hwan; Lee, Ok-Gyu

    2013-05-01

    Smoking rates among Korean adult males is still high despite multifaceted efforts to reduce it. In Korea, there have been several studies on the effectiveness of smoking cessation education for inpatients, health check-ups, and smoking cessation clinics. However, there haven't been any studies on the effectiveness of smoking cessation education conducted outside the hospital. This study investigated effectiveness of brief education on smoking cessation with an expiratory carbon monoxide (CO) measurement outside the hospital among adult male office-workers in Korea. From April 1st to May 10th, 2012, we conducted a controlled trial among 95 adult male office workers over the age of 19 who smoke outside, in a public place in Seoul by cluster sampling. For the education group, we provided smoking cessation education for about 5 to 10 minutes, measured the expiratory CO level, and made the subjects complete questionnaires, while only self-help materials on quitting smoking were given to the control group. After 4 weeks, we evaluated the change in the level of motivation or success to quit smoking in both groups via e-mail or mobile phone. In the education group, the level of motivation to quit smoking was improved significantly. A multiple logistic regression analysis showed that the odds ratio of improved motivation to quit smoking in the education group was 28.10 times higher than that of the control group. Brief education on smoking cessation with expiratory CO measurement conducted outside the hospital could enhance the level of motivation to quit smoking.

  7. Pressure sound level measurements at an educational environment in Goiânia, Goiás, Brazil

    Science.gov (United States)

    Costa, J. J. L.; do Nascimento, E. O.; de Oliveira, L. N.; Caldas, L. V. E.

    2018-03-01

    In this work, 25 points located on the ground floor of the Federal Institute of Education, Science and Technology of Goias - IFG - Campus Goiânia, were analyzed in morning periods of two Saturdays. The pressure sound levels were measured at internal and external environments during routine activities seeking to perform an environmental monitoring at this institution. The initial hypothesis was that an amusement park (Mutirama Park) was responsible for originating noise pollution in the institute, but the results showed, within the campus environment, sound pressure levels in accordance with the Municipal legislation of Goiânia for all points.

  8. Development of technique for quantifying gamma emitters in metal waste. New technique of precise and automatic measurements for confirmation of clearance level of metal waste

    International Nuclear Information System (INIS)

    Hattori, Takatoshi

    2002-01-01

    A New technique of precise and automatic measurements of gamma emitters in metal waste has been developed using 3D non-contact shape measurement and monte-carlo calculation techniques in order to confirm that specific radioactivity level of metal waste satisfies the clearance level and furthermore the surface contamination level of the metal waste is below the legal standard level. The technique can give a calibration factor every measurement target automatically and realize an automatic correction for reduction of background count rate in gamma measurements due to self-shield effect of the measurement target. The accuracy of the present method has been made clear using mock-metal wastes with various types of shape, number and size. Assuming the goal of the detection limit for practical use is 25OBq in radioactivity, a concept of the practical gamma monitor has been designed so as to be able to confirm both the clearance level and surface contamination level simultaneously and to cope with the metal waste at a speed of 2-10 ton a day. (author)

  9. A flexible and cost-effective compensation method for leveling using large-scale coordinate measuring machines and its application in aircraft digital assembly

    Science.gov (United States)

    Deng, Zhengping; Li, Shuanggao; Huang, Xiang

    2018-06-01

    In the assembly process of large-size aerospace products, the leveling and horizontal alignment of large components are essential prior to the installation of an inertial navigation system (INS) and the final quality inspection. In general, the inherent coordinate systems of large-scale coordinate measuring devices are not coincident with the geodetic horizontal system, and a dual-axis compensation system is commonly required for the measurement of difference in heights. These compensation systems are expensive and dedicated designs for different devices at present. Considering that a large-size assembly site usually needs more than one measuring device, a compensation approach which is versatile for different devices would be a more convenient and economic choice for manufacturers. In this paper, a flexible and cost-effective compensation method is proposed. Firstly, an auxiliary measuring device called a versatile compensation fixture (VCF) is designed, which mainly comprises reference points for coordinate transformation and a dual-axis inclinometer, and a kind of network tighten points (NTPs) are introduced and temporarily deployed in the large measuring space to further reduce transformation error. Secondly, the measuring principle of height difference is studied, based on coordinate transformation theory and trigonometry while considering the effects of earth curvature, and the coordinate transformation parameters are derived by least squares adjustment. Thirdly, the analytical solution of leveling uncertainty is analyzed, based on which the key parameters of the VCF and the proper deployment of NTPs are determined according to the leveling accuracy requirement. Furthermore, the proposed method is practically applied to the assembly of a large helicopter by developing an automatic leveling and alignment system. By measuring four NTPs, the leveling uncertainty (2σ) is reduced by 29.4% to about 0.12 mm, compared with that without NTPs.

  10. Examining the Level of Career maturity among Foreign Asian Students by measuring Academic Level

    Directory of Open Access Journals (Sweden)

    Mustafa Tekke

    2013-02-01

    Full Text Available The Asian individuals are dependent and collectivist compared with the western individuals that are independent and individualistic. Foreign Asian students choosing similar courses with their country friends do not reveal their career maturity and also lead to negative effect on their choices.  This study aims at examining the level of career maturity of foreign Asian students in Malaysia based on academic level by using the Career Maturity Inventory. Two hundred and twenty nine ( Male=106, Female= 123 international students studying in various semesters completed the Career Maturity Inventory and it was reported that there were no significant differences between respondents of different academic semesters with regard to level of career maturity, this might reflect an educational level bias in the construction of the career decision-making. The findings of the current study are not consistent with theoretical expectations and prior research that international undergraduate senior students would be having higher career maturity than international undergraduate fresh students. Research emphasizes the reason behind might result from dependent and collectivist Asian culture that leading to fresh international students are higher career maturity compared to senior international students.

  11. Key Informant Models for Measuring Group-Level Variables in Small Groups: Application to Plural Subject Theory

    Science.gov (United States)

    Algesheimer, René; Bagozzi, Richard P.; Dholakia, Utpal M.

    2018-01-01

    We offer a new conceptualization and measurement models for constructs at the group-level of analysis in small group research. The conceptualization starts with classical notions of group behavior proposed by Tönnies, Simmel, and Weber and then draws upon plural subject theory by philosophers Gilbert and Tuomela to frame a new perspective…

  12. Radiation level measured by a portable Geiger-Mueller counter at the altitude of commercial air routes

    International Nuclear Information System (INIS)

    Araki, Takashi

    1995-01-01

    The background intensities of naturally occurring radiation were measured aboard scheduled commercial airplanes using a newly developed Geiger-Mueller counter with a pocket computer. The preliminary results show that the radiation at the cruising altitude of a commercial airplane on a transcontinental flight is 40 times higher than the ground-level. (author)

  13. Lifetime measurements of odd-parity high-excitation levels of Sn I by time-resolved laser spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei; Feng, Yanyan; Xu, Jiaxin; Dai, Zhenwen [College of Physics, Jilin University and Key Lab of Coherent Light, Atomic and Molecular Spectroscopy, Ministry of Education, Changchun 130021 (China); Palmeri, Patrick; Quinet, Pascal; Biemont, Emile, E-mail: dai@jlu.edu.c [Astrophysique et Spectroscopie, Universite de Mons-UMONS, B-7000 Mons (Belgium)

    2010-10-28

    Natural radiative lifetimes of 38 odd-parity highly excited levels in neutral tin in the energy range from 43 682.737 to 56 838.68 cm{sup -1} have been measured by a time-resolved laser-induced fluorescence technique in an atomic beam produced by laser ablation on a solid tin sample. All the levels were excited from the metastable {sup 3}P{sub 1,} {sub 2} and {sup 1}D{sub 2} levels in the ground configuration. The second and third harmonics of a dye laser were adopted as the tunable exciting source (207-250 nm). The lifetime results obtained in this paper are in the range from 4.6 to 292 ns and will be useful in extending the set of oscillator strengths available in Sn I.

  14. Measurements of the Received Signal Level and Service Coverage Area at the IEEE 802.11 Access Point in the Building

    Science.gov (United States)

    Gunantara, N.; Sudiarta, P. K.; Prasetya, AAN A. I.; Dharma, A.; Gde Antara, I. N.

    2018-04-01

    Access point (AP) is part of a Wireless Local Access Network (WLAN) with its communications using WiFi. AP is used to transmit and receive data to users/clients. The ability of AP to serve users/clients depends on many factors. Moreover, if AP is applied in conditions inside the building. In this study, AP is installed at two points inside the building and then measured in the form of the received signal level (RSL) and service coverage area. One AP measured its performance by 26 measurement points and the other AP measured its performance by 20 measurement points. When AP has measured its performance then another AP position is switched off. Based on the measurement result, the received signal level value is the highest value is about -47 dBm at a distance of 3.2 m, while the lowest is about -79 dBm at a 9.21 m because it is on barrier 2 walls. While based on service coverage area, the area which is far away from the AP then the quality of service becomes bad because the transmitted signal is weakening caused by the distance and the loss of the wall.

  15. High performance gamma measurements of equipment retrieved from Hanford high-level nuclear waste tanks

    International Nuclear Information System (INIS)

    Troyer, G.L.

    1997-01-01

    The cleanup of high level defense nuclear waste at the Hanford site presents several progressive challenges. Among these is the removal and disposal of various components from buried active waste tanks to allow new equipment insertion or hazards mitigation. A unique automated retrieval system at the tank provides for retrieval, high pressure washing, inventory measurement, and containment for disposal. Key to the inventory measurement is a three detector HPGe high performance gamma spectroscopy system capable of recovering data at up to 90% saturation (200,000 counts per second). Data recovery is based on a unique embedded electronic pulser and specialized software to report the inventory. Each of the detectors have different shielding specified through Monte Carlo simulation with the MCNP program. This shielding provides performance over a dynamic range of eight orders of magnitude. System description, calibration issues and operational experiences are discussed

  16. High performance gamma measurements of equipment retrieved from Hanford high-level nuclear waste tanks

    Energy Technology Data Exchange (ETDEWEB)

    Troyer, G.L.

    1997-03-17

    The cleanup of high level defense nuclear waste at the Hanford site presents several progressive challenges. Among these is the removal and disposal of various components from buried active waste tanks to allow new equipment insertion or hazards mitigation. A unique automated retrieval system at the tank provides for retrieval, high pressure washing, inventory measurement, and containment for disposal. Key to the inventory measurement is a three detector HPGe high performance gamma spectroscopy system capable of recovering data at up to 90% saturation (200,000 counts per second). Data recovery is based on a unique embedded electronic pulser and specialized software to report the inventory. Each of the detectors have different shielding specified through Monte Carlo simulation with the MCNP program. This shielding provides performance over a dynamic range of eight orders of magnitude. System description, calibration issues and operational experiences are discussed.

  17. Sea level: measuring the bounding surfaces of the ocean.

    Science.gov (United States)

    Tamisiea, Mark E; Hughes, Chris W; Williams, Simon D P; Bingley, Richard M

    2014-09-28

    The practical need to understand sea level along the coasts, such as for safe navigation given the spatially variable tides, has resulted in tide gauge observations having the distinction of being some of the longest instrumental ocean records. Archives of these records, along with geological constraints, have allowed us to identify the century-scale rise in global sea level. Additional data sources, particularly satellite altimetry missions, have helped us to better identify the rates and causes of sea-level rise and the mechanisms leading to spatial variability in the observed rates. Analysis of all of the data reveals the need for long-term and stable observation systems to assess accurately the regional changes as well as to improve our ability to estimate future changes in sea level. While information from many scientific disciplines is needed to understand sea-level change, this review focuses on contributions from geodesy and the role of the ocean's bounding surfaces: the sea surface and the Earth's crust. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  18. Validation of self-reported smoking status by measuring serum cotinine levels: an Indian perspective.

    Science.gov (United States)

    Jeemon, P; Agarwal, S; Ramakrishnan, L; Gupta, R; Snehi, U; Chaturvedi, V; Reddy, K S; Prabhakaran, D

    2010-01-01

    Serum cotinine levels are a reliable marker of tobacco use. Few studies have validated questionnaires assessing smoking and exposure to environmental tobacco smoke (ETS) against serum levels. We undertook such a study in industrial workers in India. We chose 426 individuals by stratified random sampling from a database of 3397 individuals surveyed at New Delhi for the cardiovascular disease surveillance programme in a large industrial setting. Questionnaires assessing details of smoking practices and duration of exposure to ETS (if any) were administered. Cotinine levels were measured in the blood samples of these individuals. The study population comprised 142 nonsmokers not exposed to ETS, 142 non-smokers exposed to ETS and 142 active smokers. Cotinine levels among nonsmokers not exposed to ETS were non-detectable; and for non-smokers exposed to ETS and active smokers, the median (interquartile range) levels were non-detectable (non-detectable to 46.1 ng/ml) and 336 ng/ml (204-500 ng/ml), respectively. The best combined sensitivity (91%) and specificity (87.2%) yielded a cotinine cut-off level of 40.35 ng/ml to differentiate active smokers from non-smokers not exposed to ETS and those exposed to ETS (area under the curve 0.902). The cut-off cotinine level was estimated at 10.95 ng/ml using a similar analysis (sensitivity 43%, specificity 82%; area under the curve 0.64) to distinguish non-smokers not exposed to ETS from those exposed to ETS. The misclassification rate was estimated at 19% and 57.1% among self-reported non-smokers not exposed to ETS and those exposed to ETS, respectively. Obtaining a history of tobacco use is an accurate method of detecting smokers in epidemiological studies whereas serum cotinine levels accurately differentiate smokers from non-smokers. However, a brief questionnaire assessing passive exposure to smoke has poor sensitivity in distinguishing non-smokers exposed to ETS from those not exposed to ETS.

  19. Measuring Regional Price Levels in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Jiří Mrázek

    2017-09-01

    Full Text Available Regional price level comparison in the Czech Republic was a topic not touched until recently. Then a team of researchers from the University of Economics in Prague pioneered the way for NUTS 3 regions for the year 2007 and repeatedly in 2012. Another step to establish more reliable results came together with a research team of the Technical University in Liberec, which brought qualitatively new and well advanced approaches. This article aims to discuss some aspects of the two attempts to establish regional price level compariso in the Czech Republic.

  20. Measurement of insulin and C-peptide excitatory test levels in gestational diabetes mellitus

    International Nuclear Information System (INIS)

    Du Tongxin; Wang Zizheng

    2001-01-01

    To investigate the function of islet β cells in patients with gestational diabetes mellitus (GDM), serum insulin and C-peptide (C-P) excitatory test levels were measured dynamically by radioimmunoassay in 41 patients with GDM and 30 normal pregnant controls. The results showed that there were significant difference in insulin and C-peptide excitatory test levels between normal pregnancy for 32-40 weeks and patients with GDM (P < 0.001). The secretory peak of insulin occurred at 60 min in normal pregnancy, while at 120 min in patients with GDM, and the recovery postponed in patients with GDM. The peak time for C-P was just as same as that of insulin, but the peak error for C-P between normal pregnant controls and patients with GDM was more larger than that for insulin and it recovered more slowly. It suggested that majority of islet β cells in patients with GDM were good enough for response to islet resistance factors and big stress from pregnancy, and also suggested a relation between pregnancy and islet β cells function

  1. Water Level Loggers as a Low-Cost Tool for Monitoring of Stormwater Control Measures

    Directory of Open Access Journals (Sweden)

    Laura Toran

    2016-08-01

    Full Text Available Stormwater control measures (SCMs are a key component of watershed health in urbanized areas. SCMs are used to increase infiltration and reduce discharge to streams or storm sewer systems during rain events. Monitoring is important for the evaluation of design and causes of failure in SCMs. However, the expense of monitoring means it is not always included in stormwater control planning. This study shows how low-cost water level loggers can be used to answer certain questions about SCM performance. Five case studies are presented that use water level loggers to evaluate the overflow of basins, compare a traditional stormpipe trench with an infiltration trench, monitor timing of blue roof storage, show the effects of retrofitting a basin, and provide long term performance data. Water level loggers can be used to answer questions about the timing and location of stormwater overflows, which helps to evaluate the effectiveness of SCMs. More expensive monitoring and modeling can be used as a follow up if needed to more thoroughly assess a site. Nonetheless, low-cost monitoring can be a first step in identifying sites that need improvement or additional monitoring.

  2. Indoor aldehydes: measurement of contamination levels and identification of their determinants in Paris dwellings

    International Nuclear Information System (INIS)

    Clarisse, B.; Laurent, A.M.; Seta, N.; Le Moullec, Y.; El Hasnaoui, A.; Momas, I.

    2003-01-01

    The recent increased prevalence of childhood asthma and atopy has brought into question the impact of outdoor pollutants and indoor air quality. The contributory role of aldehydes to this problem and the fact that they are mainly derived from the domestic environment make them of particular interest. This study therefore measures six different aldehyde levels in Paris dwellings from potentially different sources and identifies their indoor determinants. The study was carried out in the three principal rooms of 61 flats with no previous history of complaint for olfactory nuisance or specific symptoms, two-thirds of the flats having been recently refurbished. Aldehydes were sampled in these rooms using passive samplers, and a questionnaire on potential aldehyde sources was filled out at the same time. A multiple linear regression model was used to investigate indoor aldehyde determinants. Our study revealed that propionaldehyde and benzaldehyde were of minor importance compared to formaldehyde, acetaldehyde, pentanal, and hexanal. We found that levels of these last four compounds depended on the age of wall or floor coverings (renovations less than 1 year old), smoking, and ambient parameters (carbon dioxide levels, temperature). These results could help in the assessment of indoor aldehyde emissions

  3. Long-term and seasonal Caspian Sea level change from satellite gravity and altimeter measurements

    Science.gov (United States)

    Chen, J. L.; Wilson, C. R.; Tapley, B. D.; Save, H.; Cretaux, Jean-Francois

    2017-03-01

    We examine recent Caspian Sea level change by using both satellite radar altimetry and satellite gravity data. The altimetry record for 2002-2015 shows a declining level at a rate that is approximately 20 times greater than the rate of global sea level rise. Seasonal fluctuations are also much larger than in the world oceans. With a clearly defined geographic region and dominant signal magnitude, variations in the sea level and associated mass changes provide an excellent way to compare various approaches for processing satellite gravity data. An altimeter time series derived from several successive satellite missions is compared with mass measurements inferred from Gravity Recovery and Climate Experiment (GRACE) data in the form of both spherical harmonic (SH) and mass concentration (mascon) solutions. After correcting for spatial leakage in GRACE SH estimates by constrained forward modeling and accounting for steric and terrestrial water processes, GRACE and altimeter observations are in complete agreement at seasonal and longer time scales, including linear trends. This demonstrates that removal of spatial leakage error in GRACE SH estimates is both possible and critical to improving their accuracy and spatial resolution. Excellent agreement between GRACE and altimeter estimates also provides confirmation of steric Caspian Sea level change estimates. GRACE mascon estimates (both the Jet Propulsion Laboratory (JPL) coastline resolution improvement version 2 solution and the Center for Space Research (CSR) regularized) are also affected by leakage error. After leakage corrections, both JPL and CSR mascon solutions also agree well with altimeter observations. However, accurate quantification of leakage bias in GRACE mascon solutions is a more challenging problem.

  4. Long-term Radon Levels and Equilibrium Factor in Some Spanish Workplaces Measured with a Passive Integrating Detector

    International Nuclear Information System (INIS)

    Baixeras, C.; Amgarou, K.; Font, Ll.; Domingo, C.

    1999-01-01

    The measurement of long-term radon levels and equilibrium factor is important to estimate the annual averaged dose due to radon progeny inhalation indoors. According to the European Union directive 96/26/EURATOM it is necessary to control the radon level in workplaces. This paper presents the radon concentration and equilibrium factor values obtained in some workplaces from the Barcelona area with a passive integrating dosemeter exposed for two months. The dosemeter consists of two Makrofol-DE nuclear etched track foils, one within a diffusion chamber and the other one bare, allowing the separated measurement of 222 Rn (C 0 ) and 214 Po (C 4 ) activity concentration respectively. The equilibrium factor is estimated from the disequilibrium degree (k 4 = C 4 /C 0 ). A description of the dosemeter and the methodology used, and an estimation of the annual dose received for the workers at the different workplaces are presented. (author)

  5. Measurement and structural relations of an authoritative school climate model: A multi-level latent variable investigation.

    Science.gov (United States)

    Konold, Timothy R; Cornell, Dewey

    2015-12-01

    This study tested a conceptual model of school climate in which two key elements of an authoritative school, structure and support variables, are associated with student engagement in school and lower levels of peer aggression. Multilevel multivariate structural modeling was conducted in a statewide sample of 48,027 students in 323 public high schools who completed the Authoritative School Climate Survey. As hypothesized, two measures of structure (Disciplinary Structure and Academic Expectations) and two measures of support (Respect for Students and Willingness to Seek Help) were associated with higher student engagement (Affective Engagement and Cognitive Engagement) and lower peer aggression (Prevalence of Teasing and Bullying) on both student and school levels of analysis, controlling for the effects of school demographics (school size, percentage of minority students, and percentage of low income students). These results support the extension of authoritative school climate model to high school and guide further research on the conditions for a positive school climate. Copyright © 2015 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  6. Reactor water level measuring device

    International Nuclear Information System (INIS)

    Kuroki, Reiji; Asano, Tamotsu.

    1996-01-01

    A condensation vessel is connected to the upper portion of a reactor pressure vessel by way of a pipeline. The lower portion of the condensation vessel is connected to a low pressure side of a differential pressure transmission device by way of a reference leg pipeline. The high pressure side of the differential pressure transmission device is connected to the lower portion of the pressure vessel by way of a pipeline. The condensation vessel is equipped with a temperature sensor. When a temperature of a gas phase portion in the condensation vessel is lowered below a predetermined level, and incondensible gases in the condensation vessel starts to be dissolved in water, signals are sent from the temperature sensor to a control device and a control valve is opened. With such a constitution, CRD driving water flows into the condensation vessel, and water in which gases at the upper portion of the condensation vessel is dissolved flows into the pressure vessel by way of a pipeline. Then, gases dissolved in a reference water column in the reference leg pipeline are eliminated and the value of a reference water pressure does not change even upon abrupt lowering of pressure. (I.N.)

  7. Reliability of measuring half-cycle cervical range of motion may be increased using a spirit level for calibration.

    Science.gov (United States)

    Wilke, Jan; Niederer, Daniel; Vogt, Lutz; Banzer, Winfried

    2018-02-01

    Assessments of range of motion (ROM) represent an essential part of clinical diagnostics. Ultrasonic movement analyses have been demonstrated to provide reliable results when analyzing complete amplitudes (e.g., flexion-extension). However, due to subjective determination of the starting position, the assessment of half-cycle movements (e.g, flexion only) is less reproducible. The present study aimed to examine the reliability of measuring half-cycle cervical ROM using a spirit level for calibration. 20 healthy subjects (30 ± 12yrs, 7♂, 13♀) participated in the randomized, controlled, cross-over trial. In two testing sessions with one week of wash-out in between, cervical ROM was measured by means of an ultrasonic 3D movement analysis system using a test-retest design (baseline and 5 min post baseline). The sessions differed with reference to the mask carrying the ultrasound markers. It was removed during the 5 min break (mask off) or not (mask on). To determine the resting position, a bull's eye spirit level was used in each measurement. With ICC values of 0.90-0.98 (mask on, p spirit level. In contrast to subjective determination of the starting position, analyzing complete movement planes does not increase reliability. Using a defined and objective zero positioning allows the evaluation of repositioning tasks. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Social Relations at the Collective Level: The Meaning and Measurement of Collective Control in Research on the Psychosocial Work Environment

    Directory of Open Access Journals (Sweden)

    Per Øystein Saksvik

    2013-09-01

    Full Text Available In this article, we suggest that organizational-level social relations should be defined and measured as workplace norms. We base this argument on new research on the components of the psychosocial work environment and on the availability of new techniques for measuring and analyzing workplace norms as organizational properties. Workplace norms emerge from interactions and negotiations among organizational actors, through which patterns of behavior, attitudes, and perspectives become defined as legitimate. This is an underestimated dimension of the psychosocial work environment that should be assessed with two types of data: self-reports by employees of their experiences in the workplace (task-level control and self-reports by employees and employers of collective or group-level norms. Hierarchical linear modeling is an especially useful tool for analyzing the relationships between workplace norms and different organizational outcomes because it allows researchers to separate the effects of individual-level variables from group or organizational-level factors. Our approach is anchored in the Nordic perspective of the work environment developed over the past 50 years.

  9. Practical appraisal of sustainable development-Methodologies for sustainability measurement at settlement level

    International Nuclear Information System (INIS)

    Moles, Richard; Foley, Walter; Morrissey, John; O'Regan, Bernadette

    2008-01-01

    This paper investigates the relationships between settlement size, functionality, geographic location and sustainable development. Analysis was carried out on a sample of 79 Irish settlements, located in three regional clusters. Two methods were selected to model the level of sustainability achieved in settlements, namely, Metabolism Accounting and Modelling of Material and Energy Flows (MA) and Sustainable Development Index Modelling. MA is a systematic assessment of the flows and stocks of material within a system defined in space and time. The metabolism of most settlements is essentially linear, with resources flowing through the urban system. The objective of this research on material and energy flows was to provide information that might aid in the development of a more circular pattern of urban metabolism, vital to sustainable development. In addition to MA, a set of forty indicators were identified and developed. These target important aspects of sustainable development: transport, environmental quality, equity and quality of life issues. Sustainability indices were derived through aggregation of indicators to measure dimensions of sustainable development. Similar relationships between settlement attributes and sustainability were found following both methods, and these were subsequently integrated to provide a single measure. Analysis identified those attributes of settlements preventing, impeding or promoting progress towards sustainability

  10. Performance of a mass spectrometer for determining low tritium levels from 3He/4He measurements

    International Nuclear Information System (INIS)

    Lynch, M.C.F.; Kay, D.J.

    1981-01-01

    The Micromass 3000 mass spectrometer is based on Clarke's 3 He/ 4 He instrument of McMaster University. The principal special features of the MM3000 are: (i) The double collector system, which uses an electron multiplier for the small 3 He + ion beams and a conventional Faraday detector for 4 He + ; (ii) The high sensitivity ion source; and (iii) The low-volume analyser tube employing static vacuum techniques. The sensitivity, resolution and background of the system are designed to permit measurement of 3 He and 4 He levels of the order of 10 -12 cm 3 STP and 10 -6 cm 3 STP, respectively, with a precision of 0.5%, although smaller quantities are detectable. The inherent resolution of the instrument is well in excess of 2000, but a resolution of 600-1000 is normally used for the 3 He + collector as this is sufficient to separate 3 He + from any interfering HD + or H + 3 ions. At this resolution 900 ions per second of 3 He + ions are obtained from 10 -12 cm 3 STP of 3 He. This is the size of 3 He samples obtained from water samples containing tritium at levels around 200 tritium units (1 tritium unit (TU) = IT/10 18 H). At lower tritium levels the 3 He + signal is correspondingly reduced, but the same techniques (described below) allow signals from 1-TU samples (5 ions/s) to be measured with good precision. The limit of detection is reached with quantities of 3 He in the region of 10 -15 cm 3 STP and tritium levels of around 0.1 TU. (author)

  11. Measurements of vertebral shape by r[iographic morphometry: sex differences and relationships with vertebral level and lumbar lordosis

    International Nuclear Information System (INIS)

    Cheng, X.G.; Sun, Y.; Boonen, S.; Nicholson, P.H.F.; Dequeker, J.; Brys, P.; Felsenberg, D.

    1998-01-01

    Objective. To examine sex-related and vertebral-level-specific differences in vertebral shape and to investigate the relationships between the lumbar lordosis angle and vertebral morphology. Design and patients. Lateral thoracic and lumbar spine r[iographs were obtained with a standardized protocol in 142 healthy men and 198 healthy women over 50 years old. Anterior (Ha), central (Hc) and posterior (Hp) heights of each vertebra from T4 to L4 were measured using a digitizing technique, and the Ha/Hp and Hc/Hp ratios were calculated. The lumbar lordosis angle was measured on the lateral lumbar spine r[iographs. Results. Ha/Hp and Hc/Hp ratios were smaller in men than women by 1.8% and 0.7%, respectively, and these ratios varied with vertebral level. Significant correlations were found between vertebral shape and the lumbar lordosis angle. Conclusions. These results demonstrate that vertebral shape varies significantly with sex, vertebral level and lumbar lordosis angle. Awareness of these relationships may help prevent misdiagnosis in clinical vertebral morphometry. (orig.)

  12. Objective measures of binaural masking level differences and comodulation masking release based on late auditory evoked potentials

    DEFF Research Database (Denmark)

    Epp, Bastian; Yasin, Ifat; Verhey, Jesko L.

    2013-01-01

    at a fixed physical intensity is varied by introducing auditory cues of (i) interaural target signal phase disparity and (ii) coherent masker level fluctuations in different frequency regions. In agreement with previous studies, psychoacoustical experiments showed that both stimulus manipulations result......The audibility of important sounds is often hampered due to the presence of other masking sounds. The present study investigates if a correlate of the audibility of a tone masked by noise is found in late auditory evoked potentials measured from human listeners. The audibility of the target sound...... in a masking release (i: binaural masking level difference; ii: comodulation masking release) compared to a condition where those cues are not present. Late auditory evoked potentials (N1, P2) were recorded for the stimuli at a constant masker level, but different signal levels within the same set of listeners...

  13. Examining the Level of Career maturity among Foreign Asian Students by measuring Academic Level

    OpenAIRE

    Mustafa Tekke; Faiz Bin Adam Ghani

    2013-01-01

    The Asian individuals are dependent and collectivist compared with the western individuals that are independent and individualistic. Foreign Asian students choosing similar courses with their country friends do not reveal their career maturity and also lead to negative effect on their choices.  This study aims at examining the level of career maturity of foreign Asian students in Malaysia based on academic level by using the Career Maturity Inventory. Two hundred and twenty nine ( Male=106, ...

  14. Carotenoid levels in human lymphocytes, measured by Raman microspectroscopy

    NARCIS (Netherlands)

    Ramanauskaite, R B; SegersNolten, IGMJ; DeGrauw, K J; Sijtsema, N M; VanderMaas, L; Greve, J; Otto, C; Figdor, C G

    1997-01-01

    Carotenoid levels in lymphocytes obtained from peripheral blood of healthy people have been investigated by Raman microspectroscopy. We observed that carotenoids are concentrated in so-called ''Gall bodies''. The level of carotenoids in living human lymphocytes was found to be age-dependent and to

  15. An automatic controlled apparatus of target chamber for atomic spectra and level lifetime measurements

    International Nuclear Information System (INIS)

    Zhao Mengchun; Yang Zhihu

    1998-01-01

    An automatically controlled apparatus of target chamber was made to measure spectra of the excited atoms and lifetime of the excited levels. The hardware is composed of nine parts including a computer and a step-motor, while the software consists of three branch programs. The maximum movable distance of target position is 65 cm with a step-length of 8.3 μm and a precision of +- 18 μm per 2 mm. On account of simple structure and double protection, the apparatus exhibits flexibility and reliability in years service

  16. Hydrological forecast of maximal water level in Lepenica river basin and flood control measures

    Directory of Open Access Journals (Sweden)

    Milanović Ana

    2006-01-01

    Full Text Available Lepenica river basin territory has became axis of economic and urban development of Šumadija district. However, considering Lepenica River with its tributaries, and their disordered river regime, there is insufficient of water for water supply and irrigation, while on the other hand, this area is suffering big flood and torrent damages (especially Kragujevac basin. The paper presents flood problems in the river basin, maximum water level forecasts, and flood control measures carried out until now. Some of the potential solutions, aiming to achieve the effective flood control, are suggested as well.

  17. Farmers prone to drought risk : why some farmers undertake farm-level risk-reduction measures while others not?

    NARCIS (Netherlands)

    Gidey, T.G.; van der Veen, A.

    2015-01-01

    This research investigates farmers’ cognitive perceptions of risk and the behavioral intentions to undertake farm-level risk-reduction measures. It has been observed that people who are susceptible to natural hazards often fail to act, or do very little, to protect their assets or lives. To answer

  18. Measuring progress of the global sea level observing system

    Science.gov (United States)

    Woodworth, Philip L.; Aarup, Thorkild; Merrifield, Mark; Mitchum, Gary T.; Le Provost, Christian

    Sea level is such a fundamental parameter in the sciences of oceanography geophysics, and climate change, that in the mid-1980s, the Intergovernmental Oceanographic Commission (IOC) established the Global Sea Level Observing System (GLOSS). GLOSS was to improve the quantity and quality of data provided to the Permanent Service for Mean Sea Level (PSMSL), and thereby, data for input to studies of long-term sea level change by the Intergovernmental Panel on Climate Change (IPCC). It would also provide the key data needed for international programs, such as the World Ocean Circulation Experiment (WOCE) and later, the Climate Variability and Predictability Programme (CLIVAR).GLOSS is now one of the main observation components of the Joint Technical Commission for Oceanography and Marine Meteorology (JCOMM) of IOC and the World Meteorological Organization (WMO). Progress and deficiencies in GLOSS were presented in July to the 22nd IOC Assembly at UNESCO in Paris and are contained in the GLOSS Assessment Report (GAR) [IOC, 2003a].

  19. Intervention levels for protective measures in nuclear accidents

    International Nuclear Information System (INIS)

    Hedemann Jensen, P.

    1992-12-01

    A radiation protection philosophy for exposure situations following an accident has been developed by international organisations such as the ICRP, IAEA, NES/OECD, FAO/WHO, and the CEC during the last decade. After the Chernobyl accident, the application of radiation protection principles for intervention situations such as exposure from accidental contamination or radon in dwellings were further developed and this work is still in progress. The present intervention policy recommended by the international organisations as well as by the Nordic radiation protection authorities is reviewed. The Nordic Intervention levels for foodstuff restrictions, both for the Chernobyl and post-Chernobyl periods, have been based on dose limits and they are therefore in conflict with international intervention policy. Illustrative examples on intervention level setting for relocation and foodstuff restrictions are derived for Nordic conditions from the optimisation principle recommended by the international organisations. Optimised Generic Intervention Levels have been determined to be about 10 mSv x month -1 for relocation/return and 5,000-30,000 Bqxkg -1 for restrictions on various foodstuffs contaminated with 137 Cs and 131 I. (au) (14 tabs., 1 ill., 16 refs.)

  20. Economic impact and effectiveness of radiation protection measures in aviation during a ground level enhancement

    Directory of Open Access Journals (Sweden)

    Matthiä Daniel

    2015-01-01

    Full Text Available In addition to the omnipresent irradiation from galactic cosmic rays (GCR and their secondary products, passengers and aircraft crew may be exposed to radiation from solar cosmic rays during ground level enhancements (GLE. In general, lowering the flight altitude and changing the flight route to lower latitudes are procedures applicable to immediately reduce the radiation exposure at aviation altitudes. In practice, however, taking such action necessarily leads to modifications in the flight plan and the consequential, additional fuel consumption constrains the mitigating measures. In this work we investigate in a case study of the ground level event of December 13th 2006 how potential mitigation procedures affect the total radiation exposure during a transatlantic flight from Seattle to Cologne taking into account constraints concerning fuel consumption and range.

  1. A STUDY OF DISPLACEMENT-LEVEL DEPENDENCY OF VERTICAL STIFFNESS OF PILE - COMPARISONS BETWEEN STATIC LOADING TEST AND MEASUREMENTS DURING TRAIN PASSING -

    Science.gov (United States)

    Nihei, Tatsuya; Nishioka, Hidetoshi; Kawamura, Chikara; Nishimura, Masahiro; Edamatsu, Masayuki; Koda, Masayuki

    In order to introduce the performance based design of pile foundation, vertical stiffness of pile is one of the important design factors. Although it had been es timated the vertical stiffness of pile had the displacement-level dependency, it had been not clarified. We compared the vertical stiffness of pile measured by two loading conditions at pile foundation of the railway viaduct. Firstly, we measured the vertical stiffness at static loading test under construction of the viaduct. Secondly, we measured the vertical stiffness at the time of train passing. So, we recognized that the extrapolation of the displacement level dependency in static loading test could evaluate the vertical stiffness of pile during train passing.

  2. Project ES3: attempting to quantify and measure the level of stress.

    Science.gov (United States)

    Aguiló, Jordi; Ferrer-Salvans, Pau; García-Rozo, Antonio; Armario, Antonio; Corbí, Ángel; Cambra, Francisco J; Bailón, Raquel; González-Marcos, Ana; Caja, Gerardo; Aguiló, Sira; López-Antón, Raúl; Arza-Valdés, Adriana; Garzón-Rey, Jorge M

    2015-11-01

    The WHO has qualified stress as a 'world epidemic' due to its increasingly greater incidence on health. The work described in this paper represents an attempt to objectively quantify the level of stress. The aim of the method developed here is to measure how close or how far a subject is from a situation that can be considered 'normal' in medical and social terms. The literature on the pathophysiology of stress and its methods of study in experiments on both animals and humans was reviewed. Nine prospective observational studies were undertaken with different types of subjects and stressors covering the different types of stress. The results of the literature review made it possible to identify the different types of stress, the indicators that yield significant results, the psychometric tests and the well-documented 'stressors'. This material was then used to design the general method and the details of the nine clinical trials. The preliminary results obtained in some of the studies were used to validate the indicators as well as the efficacy of the techniques used experimentally to diminish stress or to produce it. The early results obtained in the experimental trials show that we are on the right path towards defining and validating multivariable markers for quantifying levels of stress and also suggest that the method can be applied in a similar way to the study of mental disorders.

  3. Preliminary results of measurement of natural environmental radiation levels and doses to population in China

    International Nuclear Information System (INIS)

    Wang Qiliang; He Miaoting; Shu Qi

    1985-01-01

    In this paper the preliminary results of measurement of natural environmental radiation levels in China with RSS-111 high pressure ionization chamber and estimated doses to population are reported. A total of 2,723 indoor locales throughout China were measured. The results showed that the average absorbed dose rates in air due to gamma radiation for indoors and outdoors were 11.0 x 10 -8 Gy.h -1 and 7.4 x 10 -8 Gy.h -1 , respectively, and those due to cosmic rays were 3.2 x 10 -8 Gy.h -1 and 3.7 x 10 -8 Gy.h -1 , respectively. The annual average effective dose equivalent to population was 919 μSv, including 630 μSv from natural gamma radiation and 289 μSv from cosmic rays

  4. Direct measured systolic pressure gradients across the aorto-iliac segment in multiple-level-obstruction arteriosclerosis

    DEFF Research Database (Denmark)

    Noer, Ivan; Praestholm, J; Tønnesen, K H

    1981-01-01

    Patients with severe ischemia due to multi-level obstructions in the leg arteries both above and below the region were assessed preoperatively by intraarterial brachial and femoral artery pressure measurements. The systolic pressure drop along aorto-iliac obstructions was compared to the angiogra....... Due to large variations, however, the angiographic information was found to be useless in the individual patient. No difference in the pressure drop was found between cases in which rich and poor collateral networks were visualized....

  5. Development of nuclear thermal hydraulic verification tests and evaluation technology - Development of the ultrasonic method for two-phase mixture level measurement in nuclear reactor

    Energy Technology Data Exchange (ETDEWEB)

    No, Hee Cheon; Kim, Sang Jae; Kim, Hyung Tae; Moon, Young Min [Korea Advanced Institute of Science and Technology, Taejon (Korea)

    2000-04-01

    An ultrasonic method is developed for the measurement of the two-phase mixture level in the reactor vessel or steam generator. The ultrasonic method is selected among the several non-nuclear two-phase mixture level measurement methods through two steps of selection procedure. A commercial ultrasonic level measurement method is modified for application into the high temperature, pressure, and other conditions. The calculation method of the ultrasonic velocity is modified to consider the medium as the homogeneous mixture of air and steam, and to be applied into the high temperature and pressure conditions. The cross-correlation technique is adopted as a detection method to reduced the effects of the attenuation and the diffused reflection caused by surface fluctuation. The waveguides are developed to reduce the loss of echo and to remove the effects of obstructs. The present experimental study shows that the developed ultrasonic method measures the two-phase mixture level more accurately than the conventional methods do. 21 refs., 60 figs., 13 tabs. (Author)

  6. A methodology for the measure of secondary homes tourist flows at municipal level

    Directory of Open Access Journals (Sweden)

    Andrea Guizzardi

    2007-10-01

    Full Text Available The present public statistical system does not provide information concerning second houses touristic flows at sub-regional level. The lack limits local administrations' capabilities to take decisions about either: environmental, territorial and productive development, as well as regional governments in fair allocation of public financing. In the work, this information lack is overcome by proposing an indirect estimation methodology. Municipalities electric power consumption is proposed as an indicator of the stays on secondary homes. The indicator is connected to tourism flows considering both measurement errors and factors, modifying the local power demand. The application to Emilia-Romagna regional case allow to verify results’ coherence with officials statistics, as weel as to assess municipalities’ tourist vocation.

  7. Increased abdominal fat levels measured by bioelectrical impedance are associated with histological lesions of nonalcoholic steatohepatitis.

    Science.gov (United States)

    Margariti, Aikaterini; Kontogianni, Meropi D; Tileli, Nafsika; Georgoulis, Michael; Deutsch, Melanie; Zafeiropoulou, Rodessa; Tiniakos, Dina; Manios, Yannis; Pectasides, Dimitrios; Papatheodoridis, George V

    2015-08-01

    Abdominal fat is considered to play an important role in nonalcoholic fatty liver disease (NAFLD), although it is not adequately studied because abdominal fat levels cannot be estimated easily. In this study, associations between abdominal obesity, as assessed by abdominal bioelectrical impedance analysis (BIA), and the characteristics of patients with NAFLD were explored. Seventy-four consecutive NAFLD patients who underwent measurement of abdominal fat levels by BIA were included. Levels of abdominal fat 12.5 or less and more than 12.5 were considered to be average and increased, respectively. The mean±SD BMI was 30±4 kg/m and the mean abdominal fat levels were 16±5, whereas 26% of patients had average abdominal fat levels. Patients with average compared with those with increased abdominal fat levels were more frequently women (50 vs. 12%, P=0.001), had lower BMI (27±3 vs. 31±4 kg/m, Pabdominal fat levels (78 vs. 38%, P=0.030) and in patients with BMI 30 or more compared with less than 30 kg/m (87 vs. 48%, P=0.033), but similar in patients with increased or normal waist circumference (67 vs. 56%, P=0.693). Average levels of abdominal fat, as assessed by abdominal BIA, are mainly present in female patients with NAFLD and are associated with a lower degree of insulin resistance. Increased abdominal fat as assessed by BIA and obesity seem to represent strong risk factors for histological steatohepatitis.

  8. High-sensitivity measurements for low-level TRU wastes using advanced passive neutron techniques

    International Nuclear Information System (INIS)

    Menlove, H.O.; Eccleston, G.W.

    1992-01-01

    In recent years, both passive- and active-neutron nondestructive assay (NDA) systems have been used to measure the uranium and plutonium content in 200-ell drums. Because of the heterogeneity of the wastes, representative sampling is not possible and NDA methods are preferred over destructive analysis. Active-neutron assay systems are used to measure the fissile isotopes such as 235 U, 23 Pu, and 241 Pu; the isotopic ratios are used to infer the total plutonium content and thus the specific disintegration rate. The active systems include 14-MeV-neutron (DT) generators with delayed-neutron counting, (D,T) generators with the differential die-away technique, and 252 Cf delayed-neutron shufflers. Passive assay systems (for example, segmented gamma-ray scanners)5 have used gamma-ray sessions, while others (for example, passive drum counters) used passive-neutron signals. We have developed a new passive-neutron measurement technique to improve the accuracy and sensitivity of the NDA of plutonium scrap and waste. This new 200-ell-drum assay system combines the classical NDA method of counting passive-neutron totals and coincidences from plutonium with the new features of ''add-a-source'' (AS) and multiplicity counting to improve the accuracy of matrix corrections and statistical techniques that improve the low-level detectability limits. This paper describes the improvements we have made in passive-neutron assay systems and compares the accuracies and detectability limits of passive- and active-neutron assay systems

  9. Level population measurements on analyte atom and ion excited states in the inductively coupled plasma

    International Nuclear Information System (INIS)

    Walker, Z.H.; Blades, M.W.

    1986-01-01

    During the past decade a number of publications dealing with fundamental studies of the inductively coupled plasma (ICP) have appeared in the literature. The purpose of many of these investigations has been to understand the nature of the interaction between the plasma gas and the analyte. The general conclusion drawn from these studies has been that the ICP is very close to Local Thermodynamic Equilibrium (LTE), but that some deviations from LTE do occur. Recent studies by the authors' have been directed towards the measurement of analyte atom and ion excited state level populations with the objective of obtaining a better understanding of both ionization and excitation in the ICP discharge and the extent to which such processes contribute to a non-equilibrium state. Further discussion is drawn from similar measurements made on elements with low ionization potentials, such as Barium, as well as on elements such as Iron in the presence of Easily Ionizable Elements (EIE's). The spatial and power dependences of such measurements are also discussed

  10. The measurement of serum fibrinogen levels in patients with acute coronary syndrome

    International Nuclear Information System (INIS)

    Omran, Mohammad T.; Asadollahi, S.

    2007-01-01

    Serum fibrinogen level (SF) is thought to be one of the risk factors for coronary artery disease (CAD). The purpose of this study was to measure the SFL in patients with acute coronary syndrome (ACS). This study was performed in patients with ACS, admitted in Shahid Beheshti Hospital, Babol, Iran, from February 2005 to June 2006. Two hundred patients with ACS were divided into 4 groups: Group I - ST elevated myocardial infarction (STEMI); Group II - non-ST elevated myocardial infarction (NSTEMI), Group III - unstable angina (U/A) with ST-T change and Group IV: U/A without ST-T change. Each group includes 50 patients. Twenty-four hours after admission, the SFL was measured using chromatography methods. The data were collected and analyzed. The mean SFL per mg/dl in each group are Group I - 377.8+-28, Group II - 417.2+-26.8, Group III - 335.4+-19.8 and Group IV - 305.1+-13.8. The SFL in Group II was significantly higher in the other group (p=0.002). The SFL in Group II was higher than in Group III (p=0.02) and much higher than in Group IV (p=0.000). The SFL in Group III was more than in Group IV (p=0.018). The results show that SFL is an important marker in patients with ACS, with ST-T change. (author)

  11. Precision contact level gauge

    International Nuclear Information System (INIS)

    Krejci, M.; Pilat, M.; Stulik, P.

    1977-01-01

    Equipment was developed measuring the heavy water level in the TR-0 reactor core within an accuracy of several hundredths of a millimeter in a range of around 3.5 m and at a temperature of up to 90 degC. The equipment uses a vibrating needle contact as a high sensitivity level gauge and a servomechanical system with a motion screw carrying the gauge for monitoring and measuring the level in the desired range. The advantage of the unique level gauge consists in that that the transducer converts the measured level position to an electric signal, ie., pulse width, with high sensitivity and without hysteresis. (Kr)

  12. Importance of Performance Measurement and MCH Epidemiology Leadership to Quality Improvement Initiatives at the National, State and Local Levels.

    Science.gov (United States)

    Rankin, Kristin M; Gavin, Loretta; Moran, John W; Kroelinger, Charlan D; Vladutiu, Catherine J; Goodman, David A; Sappenfield, William M

    2016-11-01

    Purpose In recognition of the importance of performance measurement and MCH epidemiology leadership to quality improvement (QI) efforts, a plenary session dedicated to this topic was presented at the 2014 CityMatCH Leadership and MCH Epidemiology Conference. This paper summarizes the session and provides two applications of performance measurement to QI in MCH. Description Performance measures addressing processes of care are ubiquitous in the current health system landscape and the MCH community is increasingly applying QI processes, such as Plan-Do-Study-Act (PDSA) cycles, to improve the effectiveness and efficiency of systems impacting MCH populations. QI is maximally effective when well-defined performance measures are used to monitor change. Assessment MCH epidemiologists provide leadership to QI initiatives by identifying population-based outcomes that would benefit from QI, defining and implementing performance measures, assessing and improving data quality and timeliness, reporting variability in measures throughout PDSA cycles, evaluating QI initiative impact, and translating findings to stakeholders. MCH epidemiologists can also ensure that QI initiatives are aligned with MCH priorities at the local, state and federal levels. Two examples of this work, one highlighting use of a contraceptive service performance measure and another describing QI for peripartum hemorrhage prevention, demonstrate MCH epidemiologists' contributions throughout. Challenges remain in applying QI to complex community and systems-level interventions, including those aimed at improving access to quality care. Conclusion MCH epidemiologists provide leadership to QI initiatives by ensuring they are data-informed and supportive of a common MCH agenda, thereby optimizing the potential to improve MCH outcomes.

  13. Low level of objectively measured physical activity and cardiorespiratory fitness, and high prevalence of metabolic syndrome among Pakistani male immigrants in Oslo, Norway

    Directory of Open Access Journals (Sweden)

    Eivind Andersen

    2011-08-01

    Full Text Available Background: The level of physical fitness in south Asian immigrants living in Norway is largely unknown, but the level of physical activity seems to be low, possibly in part explaining their high prevalence of diabetes and cardiovascular diseases. However, previous studies have used self-reported measures of physical activity, and it might be questioned whether the previous data reflect the true physical activity level.Aim: To describe objectively measured physical activity level, cardiorespiratory fitness and diabetes risk in a group of Pakistani immigrant men living in Oslo, Norway.Methods: One hundred and fifty Pakistani immigrant men in the age group 25-60 years were included. Physical activity level was assessed with an accelerometer. Cardiorespiratory fitness was measured until exhaustion on a treadmill, and diabetes risk was evaluated with an oral glucose tolerance test.Results: Mean age was 37.3 years (SD=7.7. Total physical activity level was 308 counts/min (SD=131, and peak oxygen uptake was 34.2 ml·kg-1·min-1 (SD=5.6. Fifty percent of the participants had the metabolic syndrome, and 76% were obese. Physical activity level and cardiorespiratory fitness level were lower, and prevalence of the metabolic syndrome higher in a subgroup of taxi drivers as compared with those inother occupations (P<0.05.Conclusions: Physical activity and cardiorespiratory fitness levels are low and diabetes risk high among Pakistani immigrant men living in Oslo, especially in taxi drivers

  14. A Radiographic Measurement of the Anterior Epidural Space at L4-5 Disc Level.

    Science.gov (United States)

    Xu, Rui-Sheng; Wu, Jie-Shi; Lu, Hai-Dan; Zhu, Hao-Gang; Li, Xia; Dong, Jian; Yuan, Feng-Lai

    2017-05-01

    To observe the morphology character of the anterior epidural space at the L 4-5 disc level and to provide an anatomical basis for safely and accurately performing a percutaneous endoscopic lumbar discectomy (PELD). Fifty-five cases with L 5 S 1 lumbar disc herniation were included in this study, and cases with L 4-5 disease were excluded. When the puncture needle reached the epidural space at the L 5 S 1 level, iohexol was injected at the pressure of 50 cm H 2 O during the PELD, then C-Arm fluoroscopy was used to obtain standard lumbar frontal and lateral images. The widths of epidural space at the level of the L 4 lower endplate, the L 5 upper endplate, as well as the middle point of the L 4-5 disc were measured from the lumbar lateral X-ray film. Epidural space at the L 4-5 disc plane performs like a trapezium chart with a short side at the head end and a long side at the tail end in the lumbar lateral X-ray radiograph, while the average widths of epidural space were 10.2 ± 2.5, 12.3 ± 2.3, and 13.8 ± 2.6 mm at the upper, middle, and lower level of the L 4-5 disc. Understanding the morphological characteristics of epidural space will contribute to improving the safety of the tranforaminal percutaneous endoscopy technique. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  15. Measurement of ionizing radiation level in an high attitude town of Imesi-Ile, Osun State, Southwestern Nigeria

    International Nuclear Information System (INIS)

    Bamidele, L.

    2011-01-01

    The present work attempts to measure ionizing radiation level in an high attitude town of lmesi-Ile, Osun State, South-western, Nigeria. The measurements were carried out in 20 locations within the town using portable Digilert 50 nuclear radiation monitor. The absorbed dose rates obtained ranges from 26.6 to 48.6nGyh -1 with a mean value of 32.0nGyh -1 and deviation of about 25%. The estimated annual effective dose is 0.46mSv. This value is less than the 1mSv/year recommended for normal environment by UNSCEAR.

  16. Modeling category-level purchase timing with brand-level marketing variables

    NARCIS (Netherlands)

    D. Fok (Dennis); R. Paap (Richard)

    2003-01-01

    textabstractPurchase timing of households is usually modeled at the category level. Marketing efforts are however only available at the brand level. Hence, to describe category-level interpurchase times using marketing efforts one has to construct a category-level measure of marketing efforts from

  17. PROMETHEE: An Alpha Low Level Waste Assay System Using Passive and Active Neutron Measurement Methods

    International Nuclear Information System (INIS)

    Passard, Christian; Mariani, Alain; Jallu, Fanny; Romeyer-Dherbey, Jacques; Recroix, Herve; Rodriguez, Michel; Loridon, Joel; Denis, Caroline; Toubon, Herve

    2002-01-01

    The development of a passive-active neutron assay system for alpha low level waste characterization at the French Atomic Energy Commission is discussed. Less than 50 Bq[α] (about 50 μg Pu) per gram of crude waste must be measured in 118-l 'European' drums in order to reach the requirements for incinerating wastes. Detection limits of about 0.12 mg of effective 239 Pu in total active neutron counting, and 0.08 mg of effective 239 Pu coincident active neutron counting, may currently be detected (empty cavity, measurement time of 15 min, neutron generator emission of 1.6 x 10 8 s -1 [4π]). The most limiting parameters in terms of performances are the matrix of the drum - its composition (H, Cl...), its density, and its heterogeneity degree - and the localization and self-shielding properties of the contaminant

  18. Triglyceride level

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003493.htm Triglyceride level To use the sharing features on this page, please enable JavaScript. The triglyceride level is a blood test to measure the amount ...

  19. Relationship between fluctuations in glucose levels measured by continuous glucose monitoring and vascular endothelial dysfunction in type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Torimoto Keiichi

    2013-01-01

    Full Text Available Abstract Background Fluctuations in blood glucose level cause endothelial dysfunction and play a critical role in onset and/or progression of atherosclerosis. We hypothesized that fluctuation in blood glucose levels correlate with vascular endothelial dysfunction and that this relationship can be assessed using common bedside medical devices. Methods Fluctuations in blood glucose levels were measured over 24 hours by continuous glucose monitoring (CGM on admission day 2 in 57 patients with type 2 diabetes mellitus. The reactive hyperemia index (RHI, an index of vascular endothelial function, was measured using peripheral arterial tonometry (EndoPAT on admission day 3. Results The natural logarithmic-scaled RHI (L_RHI correlated with SD (r=−0.504; PPP=0.001 and percentage of time ≥200 mg/dl (r=−0.292; P=0.028. In 12 patients with hypoglycemia, L_RHI also correlated with the percentage of time at hypoglycemia (r=−0.589; P=0.044. L_RHI did not correlate with HbA1c or fasting plasma glucose levels. Furthermore, L_RHI did not correlate with LDL cholesterol, HDL cholesterol, and triglyceride levels or with systolic and diastolic blood pressures. Finally, multivariate analysis identified MAGE as the only significant determinant of L_RHI. Conclusions Fluctuations in blood glucose levels play a significant role in vascular endothelial dysfunction in type 2 diabetes. Trial registration UMIN000007581

  20. Correlation of Cell Surface Biomarker Expression Levels with Adhesion Contact Angle Measured by Lateral Microscopy.

    Science.gov (United States)

    Walz, Jenna A; Mace, Charles R

    2018-06-05

    Immunophenotyping is typically achieved using flow cytometry, but any influence a biomarker may have on adhesion or surface recognition cannot be determined concurrently. In this manuscript, we demonstrate the utility of lateral microscopy for correlating cell surface biomarker expression levels with quantitative descriptions of cell morphology. With our imaging system, we observed single cells from two T cell lines and two B cell lines adhere to antibody-coated substrates and quantified this adhesion using contact angle measurements. We found that SUP-T1 and CEM CD4+ cells, both of which express similar levels of CD4, experienced average changes in contact angle that were not statistically different from one another on surfaces coated in anti-CD4. However, MAVER-1 and BJAB K20 cells, both of which express different levels of CD20, underwent average changes in contact angle that were significantly different from one another on surfaces coated in anti-CD20. Our results indicate that changes in cell contact angles on antibody-coated substrates reflect the expression levels of corresponding antigens on the surfaces of cells as determined by flow cytometry. Our lateral microscopy approach offers a more reproducible and quantitative alternative to evaluate adhesion compared to commonly used wash assays and can be extended to many additional immunophenotyping applications to identify cells of interest within heterogeneous populations.

  1. Measuring the level of endorsement of the New Environmental Paradigm: a transnational study

    Directory of Open Access Journals (Sweden)

    Hodis D. Denis

    2014-05-01

    Full Text Available This study seeks to test the dimensionality and reliability of the revised New Ecological Paradigm (NEP scale and explores the degree of endorsement of the NEP among the population of Arad, Romania and Faro, Portugal. Socio-demographic variables were used along the NEP Scale in surveys conducted with face-to-face interviews, in both countries. Results show that people endorse the NEP only partially, with technological optimism and belief in unlimited resources still strongly influencing current thought. The NEP scale showed low levels of consistency among the two samples. Five latent factors were found, via principal component analysis estimation method, in both samples. Thus, the NEP scale should be considered carefully when treated as a measure of a single internally consistent construct.

  2. Effect of liner design, pulsator setting, and vacuum level on bovine teat tissue changes and milking characteristics as measured by ultrasonography

    Directory of Open Access Journals (Sweden)

    Gleeson David E

    2004-05-01

    Full Text Available Friesian-type dairy cows were milked with different machine settings to determine the effect of these settings on teat tissue reaction and on milking characteristics. Three teat-cup liner designs were used with varying upper barrel dimensions (wide-bore WB = 31.6 mm; narrow-bore NB = 21.0 mm; narrow-bore NB1 = 25.0 mm. These liners were tested with alternate and simultaneous pulsation patterns, pulsator ratios (60:40 and 67:33 and three system vacuum levels (40, 44 and 50 kPa. Teat tissue was measured using ultrasonography, before milking and directly after milking. The measurements recorded were teat canal length (TCL, teat diameter (TD, cistern diameter (CD and teat wall thickness (TWT. Teat tissue changes were similar with a system vacuum level of either 50 kPa (mid-level or 40 kPa (low-level. Widening the liner upper barrel bore dimension from 21.0 mm (P

  3. Clinical significance of measurement of changes of serum IGF-II, NO levels after treatment in pediatric patients with bronchial pneumonia

    International Nuclear Information System (INIS)

    Zhao Huajiang

    2005-01-01

    Objective: To study the clinical significance of changes of serum IGF-II and NO levels after treatment in pediatric patients with bronchial pneumonia. Methods: Serum IGF-II (with RIA) and NO (with Biochemical method) levels were measured in 38 pediatric patients with bronchial pneumonia both before and after treatment as well as in 35 controls. Results: Before treatment, in the patients the serum IGF-II, and NO levels were significantly higher than those in controls (P 0.05). Conclusion: Serum IGF-II and NO levels changes could reflect the disease status of the patients as well as the progress of diseases. (authors)

  4. Measuring the global information society - explaining digital inequality by economic level and education standard

    Science.gov (United States)

    Ünver, H.

    2017-02-01

    A main focus of this research paper is to investigate on the explanation of the ‘digital inequality’ or ‘digital divide’ by economic level and education standard of about 150 countries worldwide. Inequality regarding GDP per capita, literacy and the so-called UN Education Index seem to be important factors affecting ICT usage, in particular Internet penetration, mobile phone usage and also mobile Internet services. Empirical methods and (multivariate) regression analysis with linear and non-linear functions are useful methods to measure some crucial factors of a country or culture towards becoming information and knowledge based society. Overall, the study concludes that the convergence regarding ICT usage proceeds worldwide faster than the convergence in terms of economic wealth and education in general. The results based on a large data analysis show that the digital divide is declining over more than a decade between 2000 and 2013, since more people worldwide use mobile phones and the Internet. But a high digital inequality explained to a significant extent by the functional relation between technology penetration rates, education level and average income still exists. Furthermore it supports the actions of countries at UN/G20/OECD level for providing ICT access to all people for a more balanced world in context of sustainable development by postulating that policymakers need to promote comprehensive education worldwide by means of using ICT.

  5. Artificial Heads for High-Level Impulse Sound Measurement

    National Research Council Canada - National Science Library

    Buck, K

    1999-01-01

    If the Insertion Loss (IL) of hearing protectors has to be determined with very high impulse or continuous noise levels, the acoustic insulation of the Artificial Test Fixture has to exceed at least the Insertion Loss (IL...

  6. Methodology for setting the reference levels in the measurements of the dose rate absorbed in air due to the environmental gamma radiation

    International Nuclear Information System (INIS)

    Dominguez Ley, Orlando; Capote Ferrera, Eduardo; Caveda Ramos, Celia; Alonso Abad, Dolores

    2008-01-01

    Full text: The methodology for setting the reference levels of the measurements of the gamma dose rate absorbed in the air is described. The registration level was obtained using statistical methods. To set the alarm levels, it was necessary to begin with certain affectation level, which activates the investigation operation mode when being reached. It is was necessary to transform this affectation level into values of the indicators selected to set the appearance of an alarm in the network, allowing its direct comparison and at the same time a bigger operability of this one. The affectation level was assumed as an effective dose of 1 mSv/y, which is the international dose limit for public. The conversion factor obtained in a practical way as a consequence of the Chernobyl accident was assumed, converting the value of annual effective dose into values of effective dose rate in air. These factors are the most important in our work, since the main task of the National Network of Environmental Radiological Surveillance of the Republic of Cuba is detecting accidents with a situations regional affectation, and this accident is precisely an example of pollution at this scale. The alarm level setting was based on the results obtained in the first year of the Chernobyl accident. For this purpose, some transformations were achieved. In the final results, a correction factor was introduced depending on the year season the measurement was made. It was taken into account the influence of different meteorological events on the measurement of this indicator. (author)

  7. Directly measured free 25-hydroxy vitamin D levels show no evidence of vitamin D deficiency in young Swedish women with anorexia nervosa.

    Science.gov (United States)

    Carlsson, Martin; Brudin, Lars; Wanby, Pär

    2018-04-01

    Anorexia nervosa (AN) is an eating disorder characterized by low fat mass complicated by osteoporosis. The role of circulating vitamin D in the development of bone loss in AN is unclear. Fat mass is known to be inversely associated with vitamin D levels measured as serum levels of total, protein-bound 25-hydroxyvitamin D, but the importance of directly measured, free levels of 25(OH)D has not been determined in AN. The aim of this study was to investigate vitamin D status, as assessed by serum concentrations of total and free serum 25(OH)D in patients with AN and healthy controls. In female AN patients (n = 20), and healthy female controls (n = 78), total 25(OH)D was measured by LC-MS/MS, and free 25(OH)D with ELISA. In patients with AN bone mineral density (BMD) was determined with DEXA. There were no differences between patients and controls in total or free S-25(OH)D levels (80 ± 31 vs 72 ± 18 nmol/L, and 6.5 ± 2.5 vs 5.6 ± 1.8 pg/ml, respectively), and no association to BMD was found. In the entire group of patients and controls, both vitamin D parameters correlated with BMI, leptin, and PTH. The current study did not demonstrate a vitamin D deficiency in patients with AN and our data does not support vitamin D deficiency as a contributing factor to bone loss in AN. Instead, we observed a trend toward higher vitamin D levels in AN subjects compared to controls. Measurement of free vitamin D levels did not contribute to additional information.

  8. Objective measures of binaural masking level differences and comodulation masking release based on late auditory evoked potentials.

    Science.gov (United States)

    Epp, Bastian; Yasin, Ifat; Verhey, Jesko L

    2013-12-01

    The audibility of important sounds is often hampered due to the presence of other masking sounds. The present study investigates if a correlate of the audibility of a tone masked by noise is found in late auditory evoked potentials measured from human listeners. The audibility of the target sound at a fixed physical intensity is varied by introducing auditory cues of (i) interaural target signal phase disparity and (ii) coherent masker level fluctuations in different frequency regions. In agreement with previous studies, psychoacoustical experiments showed that both stimulus manipulations result in a masking release (i: binaural masking level difference; ii: comodulation masking release) compared to a condition where those cues are not present. Late auditory evoked potentials (N1, P2) were recorded for the stimuli at a constant masker level, but different signal levels within the same set of listeners who participated in the psychoacoustical experiment. The data indicate differences in N1 and P2 between stimuli with and without interaural phase disparities. However, differences for stimuli with and without coherent masker modulation were only found for P2, i.e., only P2 is sensitive to the increase in audibility, irrespective of the cue that caused the masking release. The amplitude of P2 is consistent with the psychoacoustical finding of an addition of the masking releases when both cues are present. Even though it cannot be concluded where along the auditory pathway the audibility is represented, the P2 component of auditory evoked potentials is a candidate for an objective measure of audibility in the human auditory system. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Size-dependent energy levels of InSb quantum dots measured by scanning tunneling spectroscopy.

    Science.gov (United States)

    Wang, Tuo; Vaxenburg, Roman; Liu, Wenyong; Rupich, Sara M; Lifshitz, Efrat; Efros, Alexander L; Talapin, Dmitri V; Sibener, S J

    2015-01-27

    The electronic structure of single InSb quantum dots (QDs) with diameters between 3 and 7 nm was investigated using atomic force microscopy (AFM) and scanning tunneling spectroscopy (STS). In this size regime, InSb QDs show strong quantum confinement effects which lead to discrete energy levels on both valence and conduction band states. Decrease of the QD size increases the measured band gap and the spacing between energy levels. Multiplets of equally spaced resonance peaks are observed in the tunneling spectra. There, multiplets originate from degeneracy lifting induced by QD charging. The tunneling spectra of InSb QDs are qualitatively different from those observed in the STS of other III-V materials, for example, InAs QDs, with similar band gap energy. Theoretical calculations suggest the electron tunneling occurs through the states connected with L-valley of InSb QDs rather than through states of the Γ-valley. This observation calls for better understanding of the role of indirect valleys in strongly quantum-confined III-V nanomaterials.

  10. Childhood Socioeconomic Position and Objectively Measured Physical Capability Levels in Adulthood: A Systematic Review and Meta-Analysis

    DEFF Research Database (Denmark)

    Birnie, Kate; Cooper, Rachel; Martin, Richard M

    2011-01-01

    for 5s of 1.26 (1.02, 1.55). Adjustment for the potential mediating factors, adult SEP and body size attenuated associations greatly. However, despite this attenuation, for walking speed and chair rise time, there was still evidence of moderate associations. CONCLUSIONS: Policies targeting socioeconomic...... achieved in early adulthood, thereby affecting levels in later adulthood. We have undertaken a systematic review with meta-analyses to test the hypothesis that adverse childhood SEP is associated with lower levels of objectively measured physical capability in adulthood. METHODS AND FINDINGS: Relevant...... inequalities in childhood may have additional benefits in promoting the maintenance of independence in later life....

  11. A unique automation platform for measuring low level radioactivity in metabolite identification studies.

    Directory of Open Access Journals (Sweden)

    Joel Krauser

    Full Text Available Generation and interpretation of biotransformation data on drugs, i.e. identification of physiologically relevant metabolites, defining metabolic pathways and elucidation of metabolite structures, have become increasingly important to the drug development process. Profiling using (14C or (3H radiolabel is defined as the chromatographic separation and quantification of drug-related material in a given biological sample derived from an in vitro, preclinical in vivo or clinical study. Metabolite profiling is a very time intensive activity, particularly for preclinical in vivo or clinical studies which have defined limitations on radiation burden and exposure levels. A clear gap exists for certain studies which do not require specialized high volume automation technologies, yet these studies would still clearly benefit from automation. Use of radiolabeled compounds in preclinical and clinical ADME studies, specifically for metabolite profiling and identification are a very good example. The current lack of automation for measuring low level radioactivity in metabolite profiling requires substantial capacity, personal attention and resources from laboratory scientists. To help address these challenges and improve efficiency, we have innovated, developed and implemented a novel and flexible automation platform that integrates a robotic plate handling platform, HPLC or UPLC system, mass spectrometer and an automated fraction collector.

  12. A Unique Automation Platform for Measuring Low Level Radioactivity in Metabolite Identification Studies

    Science.gov (United States)

    Krauser, Joel; Walles, Markus; Wolf, Thierry; Graf, Daniel; Swart, Piet

    2012-01-01

    Generation and interpretation of biotransformation data on drugs, i.e. identification of physiologically relevant metabolites, defining metabolic pathways and elucidation of metabolite structures, have become increasingly important to the drug development process. Profiling using 14C or 3H radiolabel is defined as the chromatographic separation and quantification of drug-related material in a given biological sample derived from an in vitro, preclinical in vivo or clinical study. Metabolite profiling is a very time intensive activity, particularly for preclinical in vivo or clinical studies which have defined limitations on radiation burden and exposure levels. A clear gap exists for certain studies which do not require specialized high volume automation technologies, yet these studies would still clearly benefit from automation. Use of radiolabeled compounds in preclinical and clinical ADME studies, specifically for metabolite profiling and identification are a very good example. The current lack of automation for measuring low level radioactivity in metabolite profiling requires substantial capacity, personal attention and resources from laboratory scientists. To help address these challenges and improve efficiency, we have innovated, developed and implemented a novel and flexible automation platform that integrates a robotic plate handling platform, HPLC or UPLC system, mass spectrometer and an automated fraction collector. PMID:22723932

  13. The Global Survey Method Applied to Ground-level Cosmic Ray Measurements

    Science.gov (United States)

    Belov, A.; Eroshenko, E.; Yanke, V.; Oleneva, V.; Abunin, A.; Abunina, M.; Papaioannou, A.; Mavromichalaki, H.

    2018-04-01

    The global survey method (GSM) technique unites simultaneous ground-level observations of cosmic rays in different locations and allows us to obtain the main characteristics of cosmic-ray variations outside of the atmosphere and magnetosphere of Earth. This technique has been developed and applied in numerous studies over many years by the Institute of Terrestrial Magnetism, Ionosphere and Radiowave Propagation (IZMIRAN). We here describe the IZMIRAN version of the GSM in detail. With this technique, the hourly data of the world-wide neutron-monitor network from July 1957 until December 2016 were processed, and further processing is enabled upon the receipt of new data. The result is a database of homogeneous and continuous hourly characteristics of the density variations (an isotropic part of the intensity) and the 3D vector of the cosmic-ray anisotropy. It includes all of the effects that could be identified in galactic cosmic-ray variations that were caused by large-scale disturbances of the interplanetary medium in more than 50 years. These results in turn became the basis for a database on Forbush effects and interplanetary disturbances. This database allows correlating various space-environment parameters (the characteristics of the Sun, the solar wind, et cetera) with cosmic-ray parameters and studying their interrelations. We also present features of the coupling coefficients for different neutron monitors that enable us to make a connection from ground-level measurements to primary cosmic-ray variations outside the atmosphere and the magnetosphere. We discuss the strengths and weaknesses of the current version of the GSM as well as further possible developments and improvements. The method developed allows us to minimize the problems of the neutron-monitor network, which are typical for experimental physics, and to considerably enhance its advantages.

  14. Cortisol level

    Science.gov (United States)

    ... enable JavaScript. The cortisol blood test measures the level of cortisol in the blood. Cortisol is a ... in the morning. This is important, because cortisol level varies throughout the day. You may be asked ...

  15. Water level measurement system in reactor pressure vessel of BWR and hydrogen concentration monitoring system for severe accident

    International Nuclear Information System (INIS)

    Kuroda, Hidehiko; Okazaki, Koki; Shiraishi, Fujio; Kenjyo, Hiroaki; Isoda, Koichiro

    2013-01-01

    TEPCO's Fukushima Daiichi Nuclear Power Station Accident caused severe accident to lose functions of many instrumentation systems. As a result, many important plant parameters couldn't be monitored. In order to monitor plant parameters in the case of severe accident, new instrumentation systems available in the severe conditions are being developed. Water level in reactor pressure vessel and hydrogen concentration in primary containment vessel are one of the most important parameters. Performance test results about water level measurement sensor and hydrogen sensor in severe environmental conditions are described. (author)

  16. Wind turbine blades condition assessment based on vibration measurements and the level of an empirically decomposed feature

    International Nuclear Information System (INIS)

    Abouhnik, Abdelnasser; Albarbar, Alhussein

    2012-01-01

    Highlights: ► We used finite element method to model wind turbine induced vibration characteristics. ► We developed a technique for eliminating wind turbine’s vibration modulation problems. ► We use empirical mode decomposition to decompose the vibration into its fundamental elements. ► We show the area under shaft speed is a good indicator for assessing wind blades condition. ► We validate the technique under different wind turbine speeds and blade (cracks) conditions. - Abstract: Vibration based monitoring techniques are well understood and widely adopted for monitoring the condition of rotating machinery. However, in the case of wind turbines the measured vibration is complex due to the high number of vibration sources and modulation phenomenon. Therefore, extracting condition related information of a specific element e.g. blade condition is very difficult. In the work presented in this paper wind turbine vibration sources are outlined and then a three bladed wind turbine vibration was simulated by building its model in the ANSYS finite element program. Dynamic analysis was performed and the fundamental vibration characteristics were extracted under two healthy blades and one blade with one of four cracks introduced. The cracks were of length (10 mm, 20 mm, 30 mm and 40 mm), all had a consistent 3 mm width and 2 mm depth. The tests were carried out for three rotation speeds; 150, 250 and 360 r/min. The effects of the seeded faults were revealed by using a novel approach called empirically decomposed feature intensity level (EDFIL). The developed EDFIL algorithm is based on decomposing the measured vibration into its fundamental components and then determines the shaft rotational speed amplitude. A real model of the simulated wind turbine was constructed and the simulation outcomes were compared with real-time vibration measurements. The cracks were seeded sequentially in one of the blades and their presence and severity were determined by decomposing

  17. Significance of measurements of changes of plasma TXB2, 6-K-PGF1α levels in patients with atrial fibrillation

    International Nuclear Information System (INIS)

    Sun Anqiong; Zan Qin; Xiao Xiaojie; Du Tongxing; Wang Zizheng

    2004-01-01

    Objective: To study the changes of plasma levels of TXB 2 , 6-K-PGF 1α in patients with atrial fibrillation (AF) and to explore the mechanism of prethrombotic state (PTS) induced by AF. Methods: Plasma levels of TXB 2 , 6-K-PGF 1α were measured with RIA in 21 patients with isolated paroxysmal atrial fibrillation (IPAF) both during and one week after termination of the attack. Levels were also measured in 28 patients with isolated sustained AF (ISAF), 27 patients with rheumatic mitral stenosis associated with persistent AF (RHD), 32 patients with paroxysmal supraventricular tachycardia (PSVT) and 35 controls. Results Plasma levels of TXB 2 and TXB 2 /6-K-PGF 1α in: (1) patients with IPAF during AF, (2) patients with ISAF and (3) patients with RHD were significantly higher than those in (1) patients with IPAF one week after termination of attack, (2) patients with PSVT and (3) the controls, but there were little difference in plasma 6-K-PGF 1α levels. Values in patients with PSVT were not much different from those in controls. Plasma TXB 2 and TXB 2 /6-K-PGF 1α levels were positively correlated to the duration of the attack, but bore no relation to such parameters as: age, sex, mitral valve area, ejection fraction and inner diameter of left atrium. Conclusion: These results indicate that the changes of TXB 2 and TXB 2 /6-K-PGF 1α levels in plasma in the patients with AF are caused by the irregular contractile activity of atrium. (authors)

  18. Surveying dwellings with high indoor radon levels: a BRE guide to radon remedial measures in existing dwellings

    International Nuclear Information System (INIS)

    Scivyer, C.R.

    1993-01-01

    This report is one of a series giving practical advice on methods of reducing radom levels in existing dwellings. It is aimed specifically at builders, surveyors and building specialists surveying for and prescribing remedial measures for dwellings. It supplements guidance available in 'The householders' guide to radon, obtainable from local environmental health officers or from the Department of the Environment. (Author)

  19. Measuring thermal neutron characteristics

    International Nuclear Information System (INIS)

    Johnstone, C.W.; Jacobson, L.A.

    1983-01-01

    A method for providing a background-compensated measurement of the level of inducted radiation within an earth formation is claimed. The formation is irradiated with a discrete burst of neutrons and the level of radiation in the formation measured. The level of background radiation is then measured. An average level of both measurements is obtained

  20. Elevated prefrontal cortex γ-aminobutyric acid and glutamate-glutamine levels in schizophrenia measured in vivo with proton magnetic resonance spectroscopy.

    Science.gov (United States)

    Kegeles, Lawrence S; Mao, Xiangling; Stanford, Arielle D; Girgis, Ragy; Ojeil, Najate; Xu, Xiaoyan; Gil, Roberto; Slifstein, Mark; Abi-Dargham, Anissa; Lisanby, Sarah H; Shungu, Dikoma C

    2012-05-01

    Postmortem studies have found evidence of γ-aminobutyric acid (GABA) deficits in fast-spiking, parvalbumin-positive interneurons in the prefrontal cortex in schizophrenia. Magnetic resonance spectroscopy studies in unmedicated patients have reported glutamine or glutamate-glutamine (Glx) elevations in this region. Abnormalities in these transmitters are thought to play a role in cognitive impairments in the illness. To measure GABA and Glx levels in vivo in 2 prefrontal brain regions in unmedicated and medicated patients with schizophrenia and healthy controls. Case-control study. Inpatient psychiatric research unit and associated outpatient clinic. Sixteen unmedicated patients with schizophrenia, 16 medicated patients, and 22 healthy controls matched for age, sex, ethnicity, parental socioeconomic status, and cigarette smoking. Proton magnetic resonance spectroscopy with a 3-T system and the J-edited spin-echo difference method. The GABA and Glx levels were measured in the dorsolateral and medial prefrontal cortex and normalized to the simultaneously acquired water signal. Working memory performance was assessed in all subjects. The GABA and Glx concentrations determined by proton magnetic resonance spectroscopy. In the medial prefrontal cortex region, 30% elevations were found in GABA (P = .02) and Glx (P = .03) levels in unmedicated patients compared with controls. There were no alterations in the medicated patients or in either group in the dorsolateral prefrontal cortex. Both regions showed correlations between GABA and Glx levels in patients and controls. No correlations with working memory performance were found. To our knowledge, this study presents the first GABA concentration measurements in unmedicated patients with schizophrenia, who showed elevations in both GABA and Glx levels in the medial prefrontal cortex but not the dorsolateral prefrontal cortex. Medicated patients did not show these elevations, suggesting possible normalization of levels with

  1. Detection of spontaneous combustion underground by measuring CO levels

    Energy Technology Data Exchange (ETDEWEB)

    Boutonnat, M; Jeger, M

    1980-01-01

    It is essential to detect spontaneous combustion as soon as it occurs so as to prevent such outbreaks from becoming a serious conflagration. At present CO detection is the basic method used. States the need for setting up additional measuring points (in air returns from working palces and in return airways in general). Where possible measuring instruments should be placed near zones where there is a particularly high risk of spontaneous combustion. Measurement should be undertaken on a continuous basis or as frequently as possible and must be capable of distinguishing between extraneous CO (shotfiring and diesel motors) and CO emanating from outbreaks of spontaneous combustion. The article describes two instruments developed by CERCHAR: the remote-control CO monitors type C and CSD. Both devices make use of a UNOR analyser.

  2. Clinical significance of measurement of changes of plasma Hcy and ET levels after treatment in patients with acute myocardial infarction (AMI)

    International Nuclear Information System (INIS)

    Zhou Feng

    2008-01-01

    Objective: To explore the clinical significance of changes of plasma Hcy and ET levels in patients with AMI after treatment. Methods: Plasma Hcy and ET levels were measured with RIA in 33 patients with acute myocardial infarction both before and after treatment as well as in 30 controls. Results: Plasma Hcy and ET levels were significantly higher in the AMI patients than those in the controls before treatment and the levels were mutually positively correlated (P 0.05), but plasma ET levels, though dropped markedly remained significantly higher (P<0.05). Conclusion: Changes of plasma Hcy and ET levels after treatment might be of prognostic importance in patients with acute myocardial infarction. (authors)

  3. A pilot study to measure levels of selected elements in Thai foods by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Laoharojanaphand, S.; Busamongkol, A.; Permnamtip, V.; Judprasong, K.; Chatt, A.

    2012-01-01

    A pilot study was carried out to evaluate the scope of instrumental neutron activation analysis (INAA) for measuring the levels of selected elements in a few commonly consumed food items in Thailand. Several varieties of rice, beans, aquatic food items, vegetables and soybean products were bought from major distribution centers in Bangkok, Thailand. Samples were prepared according to the protocols prescribed by the nutritionist for food compositional analysis. Levels of As, Br, Ca, Cd, Cl, Cr, Cu, Fe, K, Mg, Mn, and Zn were measured by INAA using the irradiation and counting facilities available at the Thai Research Reactor with the maximum in-core thermal neutron flux of 3 x 10 13 cm -2 s -1 of the Thailand Institute of Nuclear Technology in Bangkok. Selenium was determined by cyclic INAA using the Dalhousie University SLOWPOKE-2 Reactor facilities in Halifax, Canada at a thermal neutron flux of 2.5 x 10 11 cm -2 s -1 . Both cooked and uncooked foods were analyzed. The elemental composition of food products was found to depend significantly on the raw material as well as the preparation technique. (author)

  4. Measurement of high natural background radiation levels by TLD at Cox's Bazar coastal areas in Bangladesh

    International Nuclear Information System (INIS)

    Mollah, A.S.; Rahman, M.M.; Koddus, M.A.; Husain, S.R.; Malek, M.A.

    1987-01-01

    High natural background radiation levels at the Cox's Bazar coastal areas in Bangladesh were measured by LiF (TLD-100) dosemeters. The dose rates varied from 2621 to 35391 μGy.y -1 with a mean of 11968 μGy.y -1 . The average dose rate is found to significantly higher than the world average value. In order to formulate appropriate guidelines for radiation protection of the population in this area, the necessary recommendations are described. (author)

  5. Sea level hazards: Altimetric monitoring of tsunamis and sea level rise

    Science.gov (United States)

    Hamlington, Benjamin Dillon

    Whether on the short timescale of an impending tsunami or the much longer timescale of climate change-driven sea level rise, the threat stemming from rising and inundating ocean waters is a great concern to coastal populations. Timely and accurate observations of potentially dangerous changes in sea level are vital in determining the precautionary steps that need to be taken in order to protect coastal communities. While instruments from the past have provided in situ measurements of sea level at specific locations across the globe, satellites can be used to provide improved spatial and temporal sampling of the ocean in addition to producing more accurate measurements. Since 1993, satellite altimetry has provided accurate measurements of sea surface height (SSH) with near-global coverage. Not only have these measurements led to the first definitive estimates of global mean sea level rise, satellite altimetry observations have also been used to detect tsunami waves in the open ocean where wave amplitudes are relatively small, a vital step in providing early warning to those potentially affected by the impending tsunami. The use of satellite altimetry to monitor two specific sea level hazards is examined in this thesis. The first section will focus on the detection of tsunamis in the open ocean for the purpose of providing early warning to coastal inhabitants. The second section will focus on estimating secular trends using satellite altimetry data with the hope of improving our understanding of future sea level change. Results presented here will show the utility of satellite altimetry for sea level monitoring and will lay the foundation for further advancement in the detection of the two sea level hazards considered.

  6. Implementing and measuring the level of laboratory service integration in a program setting in Nigeria.

    Directory of Open Access Journals (Sweden)

    Henry Mbah

    Full Text Available The surge of donor funds to fight HIV&AIDS epidemic inadvertently resulted in the setup of laboratories as parallel structures to rapidly respond to the identified need. However these parallel structures are a threat to the existing fragile laboratory systems. Laboratory service integration is critical to remedy this situation. This paper describes an approach to quantitatively measure and track integration of HIV-related laboratory services into the mainstream laboratory services and highlight some key intervention steps taken, to enhance service integration.A quantitative before-and-after study conducted in 122 Family Health International (FHI360 supported health facilities across Nigeria. A minimum service package was identified including management structure; trainings; equipment utilization and maintenance; information, commodity and quality management for laboratory integration. A check list was used to assess facilities at baseline and 3 months follow-up. Level of integration was assessed on an ordinal scale (0 = no integration, 1 = partial integration, 2 = full integration for each service package. A composite score grading expressed as a percentage of total obtainable score of 14 was defined and used to classify facilities (≤ 80% FULL, 25% to 79% PARTIAL and <25% NO integration. Weaknesses were noted and addressed.We analyzed 9 (7.4% primary, 104 (85.2% secondary and 9 (7.4% tertiary level facilities. There were statistically significant differences in integration levels between baseline and 3 months follow-up period (p<0.01. Baseline median total integration score was 4 (IQR 3 to 5 compared to 7 (IQR 4 to 9 at 3 months follow-up (p = 0.000. Partial and fully integrated laboratory systems were 64 (52.5% and 0 (0.0% at baseline, compared to 100 (82.0% and 3 (2.4% respectively at 3 months follow-up (p = 0.000.This project showcases our novel approach to measure the status of each laboratory on the integration continuum.

  7. Infrared spectroscopic measurement of skin hydration and sebum levels and comparison to corneometer and sebumeter

    Science.gov (United States)

    Ezerskaia, Anna; Pereira, S. F.; Urbach, H. P.; Varghese, Babu

    2016-05-01

    Skin health characterized by a system of water and lipids in Stratum Corneum provide protection from harmful external elements and prevent trans-epidermal water loss. Skin hydration (moisture) and sebum (skin surface lipids) are considered to be important factors in skin health; a right balance between these components is an indication of skin health and plays a central role in protecting and preserving skin integrity. In this manuscript we present an infrared spectroscopic method for simultaneous and quantitative measurement of skin hydration and sebum levels utilizing differential detection with three wavelengths 1720, 1750, and 1770 nm, corresponding to the lipid vibrational bands that lie "in between" the prominent water absorption bands. The skin sebum and hydration values on the forehead under natural conditions and its variations to external stimuli were measured using our experimental set-up. The experimental results obtained with the optical set-up show good correlation with the results obtained with the commercially available instruments Corneometer and Sebumeter.

  8. Measuring HIV stigma at the family level: psychometric assessment of the Chinese Courtesy Stigma Scales (CCSSs).

    Science.gov (United States)

    Liu, Hongjie; Xu, Yongfang; Sun, Yehuan; Dumenci, Levent

    2014-01-01

    Courtesy stigma is the stigmatization a person perceives or experiences due to their association with a stigmatized individual or group. Most HIV-related stigma scales have been developed for people living with HIV/AIDS (PLWHAs), but not for their HIV-uninfected family members. To date, few measurement scales have been designed to measure the degree of stigma among both PLWHAs and their HIV-uninfected family members at the family level. We developed a set of courtesy stigma scales and estimated their reliability and validity from 256 PLWHAs and 256 of their HIV-uninfected family members. Exploratory and confirmatory factor analyses were performed in two independent samples: a development sample (N = 216) and a validation sample (N = 296), respectively. Two factors ("public stigma" and "self-perceived stigma") had high internal consistency reliability (Cronbach's alpha coefficient between 0.83-0.90) and good construct validity (standardized factor loading range: 0.37-0.95) in both samples. These findings document that the newly developed brief instrument is a psychometrically sound measure of HIV-related stigma among both PLWHAs and their HIV-uninfected family members.

  9. A Firm Level Study of Information Technology Productivity in Europe Using Financial and Market Based Measures

    Directory of Open Access Journals (Sweden)

    Alan Peslak

    2004-05-01

    Full Text Available For many years, business has invested significant resources in information technology, hardware, software, and manpower. The Productivity Paradox is the seeming lack of productivity gains despite the increased investment in IT. For many years the existence of a Productivity Paradox has been the subject of research interest. Conflicting results have been obtained from a variety of data sets. Until this time however there has been no study that has investigated European companies’ use of information technology and its impact on productivity. The objective of this study was to investigate information technology productivity with a new data set from a European published source, and measuring productivity using both market and financial based measures. Results of the study indicated that information technology did have a consistent positive impact on firm level productivity in Europe for the years 1996, 1997, and 1998. Both market and financial based productivity measures provided consistent positive significant returns with regard to IT productivity. The major contribution of the study is that it provides an analysis of the impact of European information technology on firm and economic productivity.

  10. Association between self-reported and objectively measured physical fitness level in a middle-aged population in primary care

    Directory of Open Access Journals (Sweden)

    Kirstine H. Obling

    2015-01-01

    Conclusion: A single-item question is a cost-effective way of measuring physical fitness level, but the method has low association and fair agreement when compared to the Aastrand test. Men tend to overestimate physical fitness more than women, which should be accounted for if using the question in primary care settings.

  11. Measurement of Deformations by MEMS Arrays, Verified at Sub-millimetre Level Using Robotic Total Stations

    Directory of Open Access Journals (Sweden)

    Tomas Beran

    2014-06-01

    Full Text Available Measurement of sub-millimetre-level deformations of structures in the presence of ambienttemperature changes can be challenging. This paper describes the measurement of astructure moving due to temperature changes, using two ShapeAccelArray (SAAinstruments, and verified by a geodetic monitoring system. SAA is a geotechnicalinstrument often used for monitoring of displacements in soil. SAA uses micro-electro-mechanical system (MEMS sensors to measure tilt in the gravity field. The geodeticmonitoring system, which uses ALERT software, senses the displacements of targetsrelative to control points, using a robotic total station (RTS. The test setup consists of acentral four-metre free-standing steel tube with other steel tubes welded to most of itslength. The central tube is anchored in a concrete foundation. This composite “pole” isequipped with two SAAs as well as three geodetic prisms mounted on the top, in the middle,and in the foundation. The geodetic system uses multiple control targets mounted inconcrete foundations of nearby buildings, and at the base of the pole. Long-termobservations using two SAAs indicate that the pole is subject to deformations due to cyclicalambient temperature variations causing the pole to move by a few millimetres each day. Ina multiple-day experiment, it was possible to track this movement using SAA as well as theRTS system. This paper presents data comparing the measurements of the two instrumentsand provides a good example of the detection of two-dimensional movements of seeminglyrigid objects due to temperature changes.

  12. Quantifying the Uncertainty in High Spatial and Temporal Resolution Synthetic Land Surface Reflectance at Pixel Level Using Ground-Based Measurements

    Science.gov (United States)

    Kong, J.; Ryu, Y.

    2017-12-01

    Algorithms for fusing high temporal frequency and high spatial resolution satellite images are widely used to develop dense time-series land surface observations. While many studies have revealed that the synthesized frequent high spatial resolution images could be successfully applied in vegetation mapping and monitoring, validation and correction of fused images have not been focused than its importance. To evaluate the precision of fused image in pixel level, in-situ reflectance measurements which could account for the pixel-level heterogeneity are necessary. In this study, the synthetic images of land surface reflectance were predicted by the coarse high-frequency images acquired from MODIS and high spatial resolution images from Landsat-8 OLI using the Flexible Spatiotemporal Data Fusion (FSDAF). Ground-based reflectance was measured by JAZ Spectrometer (Ocean Optics, Dunedin, FL, USA) on rice paddy during five main growth stages in Cheorwon-gun, Republic of Korea, where the landscape heterogeneity changes through the growing season. After analyzing the spatial heterogeneity and seasonal variation of land surface reflectance based on the ground measurements, the uncertainties of the fused images were quantified at pixel level. Finally, this relationship was applied to correct the fused reflectance images and build the seasonal time series of rice paddy surface reflectance. This dataset could be significant for rice planting area extraction, phenological stages detection, and variables estimation.

  13. The use of radiation trapping in the measurement of the electron excitation cross section for the production of the 1s4 (3P1) level of Ne

    International Nuclear Information System (INIS)

    Miers, R.E.; Gastineau, J.E.; Phillps, M.H.; Anderson, L.W.; Lin, C.C.

    1981-01-01

    The authors report the use of laser induced fluorescence for the first measurement of the electron excitation cross section for the production of the 1s 4 ( 3 P 1 ) level of Ne. Radiation trapping is used to lengthen the effective lifetime of the 1s 4 level allowing for the electron excitation cross section of the 1s 4 level to be measured in a manner similar to the measurement of electron excitation cross sections of the metastable 1s 3 and 1s 5 levels. (Auth.)

  14. Measurement of farm level efficiency of home gardens in Uyo ...

    African Journals Online (AJOL)

    To investigate the farm level efficiency of home vegetable gardens in Uyo, a stochastic production function which incorporates a model for the technical inefficiency effects was used. Using farm-level data from 80 home gardeners obtained through structured questionnaire, the parameters were estimated simultaneously with ...

  15. Analysis and modeling of wafer-level process variability in 28 nm FD-SOI using split C-V measurements

    Science.gov (United States)

    Pradeep, Krishna; Poiroux, Thierry; Scheer, Patrick; Juge, André; Gouget, Gilles; Ghibaudo, Gérard

    2018-07-01

    This work details the analysis of wafer level global process variability in 28 nm FD-SOI using split C-V measurements. The proposed approach initially evaluates the native on wafer process variability using efficient extraction methods on split C-V measurements. The on-wafer threshold voltage (VT) variability is first studied and modeled using a simple analytical model. Then, a statistical model based on the Leti-UTSOI compact model is proposed to describe the total C-V variability in different bias conditions. This statistical model is finally used to study the contribution of each process parameter to the total C-V variability.

  16. Methods of protective measures analysis in agriculture on contaminated lands: estimation of effectiveness, intervention levels and comparison of different countermeasures

    International Nuclear Information System (INIS)

    Yatsalo, B.I.; Aleksakhin, R.M.

    1997-01-01

    Methodological aspects of the analysis of protective measures in agriculture in the long-term period of liquidation of the consequences of a nuclear accident are considered. Examples of the estimations of countermeasure effectiveness with the use of the cost-benefit analysis, as well as methods of the estimation of intervention levels and examples of a comparison protective measures with the use of several criteria of effectiveness are discussed

  17. Clinical significance of measurement of changes of serum IGF-II and NO levels after treatment in elderly patients with chronic bronchitis

    International Nuclear Information System (INIS)

    Gu Tao

    2006-01-01

    Objective: To study the clinical significance of changes of serum IGF-II and NO levels after treatment in elderly patients with chronic bronchitis. Methods: Serum IGF-II (with RIA) and NO (with Biochemical method) levels were measured in 42 elderly patients with chronic bronchitis both before and after treatment as well as in 30 controls. Results: Before treatment in the patients the serum IGF-II levels were significantly higher than those in controls (P<0.01), while the NO levels were significantly lower (P<0.01). After two weeks of treatment, the levels though dropped markedly, lemained higher than those in controls (P<0. 05). Conclusion: Serum IGF-II and NO levels changes could reflect the disease status as well as the progress of diseases. (authors)

  18. Method and system for in vivo measurement of bone tissue using a two level energy source

    Science.gov (United States)

    Cameron, J. R.; Judy, P. F. (Inventor)

    1976-01-01

    Methods and apparatus are provided for radiologically determining the bone mineral content of living human bone tissue independently of the concurrent presence of adipose and other soft tissues. A target section of the body of the subject is irradiated with a beam of penetrative radiations of preselected energy to determine the attenuation of such beam with respect to the intensity of each of two radiations of different predetermined energy levels. The resulting measurements are then employed to determine bone mineral content.

  19. Physical Activity Level and Sedentary Behaviors among Public School Children in Dakar (Senegal Measured by PAQ-C and Accelerometer: Preliminary Results

    Directory of Open Access Journals (Sweden)

    Adama Diouf

    2016-10-01

    Full Text Available Background: Physical inactivity and sedentary lifestyles are major risk factors of childhood obesity. This study aimed to measure physical activity (PA levels by accelerometer and Physical Activity Questionnaire for Older Children (PAQ-C among Senegalese school children and the relation with Body Mass Index (BMI and body composition. Methodology: 156 pupils 8–11 years old were randomly selected in four elementary public schools of Dakar. BMI z-score was used to categorize children according to their weight status. PA was measured by PAQ-C in the 156 pupils and by accelerometer (Actigraph GT3X+, Pensacola, FL, USA in a subsample of 42 children. Body composition was determined by deuterium dilution method. Results: PAQ-C results were comparable in the 156 and 42 pupils. The 42 pupils presented a light activity measured by accelerometer, while PAQ-C classified the majority of them (57%; n = 24 in the moderate PA level. Children spent most of their time (min/day in sedentary activities and light activities than in moderate and intense activity levels. Accumulation of 60 min/day Moderate-to-Vigorous Physical Activity (MVPA was achieved by 54.8% (n = 23 of the pupils. MVPA decreased in girls in relation to their body fatness. There was a significant difference in MVPA between boys and girls. Similarly, overweight/obese (45 ± 16 min/day children had lower MVPA than their normal and underweight peers (88 ± 34 and 74 ± 36 min/day, respectively; p = 0.004. Conclusions: The two methods are inconsistent for measuring light and moderate PA levels. Although PAQ-C is an uncomplicated routine method, various activities were not adapted for genuine activities in Senegalese children and therefore needs to be validated in African children.

  20. Physical Activity Level and Sedentary Behaviors among Public School Children in Dakar (Senegal) Measured by PAQ-C and Accelerometer: Preliminary Results.

    Science.gov (United States)

    Diouf, Adama; Thiam, Mbeugué; Idohou-Dossou, Nicole; Diongue, Ousmane; Mégné, Ndé; Diallo, Khady; Sembène, Pape Malick; Wade, Salimata

    2016-10-10

    Background : Physical inactivity and sedentary lifestyles are major risk factors of childhood obesity. This study aimed to measure physical activity (PA) levels by accelerometer and Physical Activity Questionnaire for Older Children (PAQ-C) among Senegalese school children and the relation with Body Mass Index (BMI) and body composition. Methodology : 156 pupils 8-11 years old were randomly selected in four elementary public schools of Dakar. BMI z -score was used to categorize children according to their weight status. PA was measured by PAQ-C in the 156 pupils and by accelerometer (Actigraph GT3X+, Pensacola, FL, USA) in a subsample of 42 children. Body composition was determined by deuterium dilution method. Results : PAQ-C results were comparable in the 156 and 42 pupils. The 42 pupils presented a light activity measured by accelerometer, while PAQ-C classified the majority of them (57%; n = 24) in the moderate PA level. Children spent most of their time (min/day) in sedentary activities and light activities than in moderate and intense activity levels. Accumulation of 60 min/day Moderate-to-Vigorous Physical Activity (MVPA) was achieved by 54.8% ( n = 23) of the pupils. MVPA decreased in girls in relation to their body fatness. There was a significant difference in MVPA between boys and girls. Similarly, overweight/obese (45 ± 16 min/day) children had lower MVPA than their normal and underweight peers (88 ± 34 and 74 ± 36 min/day, respectively; p = 0.004). Conclusions : The two methods are inconsistent for measuring light and moderate PA levels. Although PAQ-C is an uncomplicated routine method, various activities were not adapted for genuine activities in Senegalese children and therefore needs to be validated in African children.