WorldWideScience

Sample records for measured freeform sources

  1. Interferometry with flexible point source array for measuring complex freeform surface and its design algorithm

    Science.gov (United States)

    Li, Jia; Shen, Hua; Zhu, Rihong; Gao, Jinming; Sun, Yue; Wang, Jinsong; Li, Bo

    2018-06-01

    The precision of the measurements of aspheric and freeform surfaces remains the primary factor restrict their manufacture and application. One effective means of measuring such surfaces involves using reference or probe beams with angle modulation, such as tilted-wave-interferometer (TWI). It is necessary to improve the measurement efficiency by obtaining the optimum point source array for different pieces before TWI measurements. For purpose of forming a point source array based on the gradients of different surfaces under test, we established a mathematical model describing the relationship between the point source array and the test surface. However, the optimal point sources are irregularly distributed. In order to achieve a flexible point source array according to the gradient of test surface, a novel interference setup using fiber array is proposed in which every point source can be independently controlled on and off. Simulations and the actual measurement examples of two different surfaces are given in this paper to verify the mathematical model. Finally, we performed an experiment of testing an off-axis ellipsoidal surface that proved the validity of the proposed interference system.

  2. Inspection of freeform surfaces considering uncertainties in measurement, localization and surface reconstruction

    International Nuclear Information System (INIS)

    Mehrad, Vahid; Xue, Deyi; Gu, Peihua

    2013-01-01

    Inspection of a manufactured freeform surface can be conducted by building its surface model and comparing this manufactured surface model with the ideal design surface model and its tolerance requirement. The manufactured freeform surface model is usually achieved by obtaining measurement points on the manufactured surface, transforming these measurement points from the measurement coordinate system to the design coordinate system through localization, and reconstructing the surface model using the localized measurement points. In this research, a method was developed to estimate the locations and their variances of any selected points on the reconstructed freeform surface considering different sources of uncertainties in measurement, localization and surface reconstruction processes. In this method, first locations and variances of the localized measurement points are calculated considering uncertainties of the measurement points and uncertainties introduced in the localization processes. Then locations and variances of points on the reconstructed freeform surface are obtained considering uncertainties of the localized measurement points and uncertainties introduced in the freeform surface reconstruction process. Two case studies were developed to demonstrate how these three different uncertainty sources influence the quality of the reconstructed freeform curve and freeform surface in inspection. (paper)

  3. Freeform surface measurement and characterisation using a toolmakers microscope

    International Nuclear Information System (INIS)

    Wong, Francis Seung-yin; Chauh, Kong-Bieng; Venuvinod, Patri K

    2014-01-01

    Current freeform surface (FFS) characterization systems mainly cover aspects related to computer-aided design/manufacture (CAD/CAM). This paper describes a new approach that extends into computer-aided inspection (CAI).The following novel features are addressed: - ◼ Feature recognition and extraction from surface data; - ◼ Characterisation of properties of the surface's M and N vectors at individual vertex; - ◼ Development of a measuring plan using a toolmakers microscope for the inspection of the FFS; - ◼ Inspection of the actual FFS produced by CNC milling; - ◼ Verification of the measurement results and comparison with the CAD design data; Tests have shown that the deviations between the CAI and CAD data were within the estimated uncertainty limits

  4. Non-contact measurement machine for freeform optics

    NARCIS (Netherlands)

    Henselmans, R.

    2009-01-01

    The performance of high-precision optical systems using spherical optics is limited by aberrations. By applying aspherical and freeform optics, the geometrical aberrations can be reduced or eliminated while at the same time also reducing the required number of components, the size and the weight of

  5. Adaptive Sampling based 3D Profile Measuring Method for Free-Form Surface

    Science.gov (United States)

    Duan, Xianyin; Zou, Yu; Gao, Qiang; Peng, Fangyu; Zhou, Min; Jiang, Guozhang

    2018-03-01

    In order to solve the problem of adaptability and scanning efficiency of the current surface profile detection device, a high precision and high efficiency detection approach is proposed for surface contour of free-form surface parts based on self- adaptability. The contact mechanical probe and the non-contact laser probe are synthetically integrated according to the sampling approach of adaptive front-end path detection. First, the front-end path is measured by the non-contact laser probe, and the detection path is planned by the internal algorithm of the measuring instrument. Then a reasonable measurement sampling is completed according to the planned path by the contact mechanical probe. The detection approach can effectively improve the measurement efficiency of the free-form surface contours and can simultaneously detect the surface contours of unknown free-form surfaces with different curvatures and even different rate of curvature. The detection approach proposed in this paper also has important reference value for free-form surface contour detection.

  6. New reversing freeform lens design method for LED uniform illumination with extended source and near field

    Science.gov (United States)

    Zhao, Zhili; Zhang, Honghai; Zheng, Huai; Liu, Sheng

    2018-03-01

    In light-emitting diode (LED) array illumination (e.g. LED backlighting), obtainment of high uniformity in the harsh condition of the large distance height ratio (DHR), extended source and near field is a key as well as challenging issue. In this study, we present a new reversing freeform lens design algorithm based on the illuminance distribution function (IDF) instead of the traditional light intensity distribution, which allows uniform LED illumination in the above mentioned harsh conditions. IDF of freeform lens can be obtained by the proposed mathematical method, considering the effects of large DHR, extended source and near field target at the same time. In order to prove the claims, a slim direct-lit LED backlighting with DHR equal to 4 is designed. In comparison with the traditional lenses, illuminance uniformity of LED backlighting with the new lens increases significantly from 0.45 to 0.84, and CV(RMSE) decreases dramatically from 0.24 to 0.03 in the harsh condition. Meanwhile, luminance uniformity of LED backlighting with the new lens is obtained as high as 0.92 at the condition of extended source and near field. This new method provides a practical and effective way to solve the problem of large DHR, extended source and near field for LED array illumination.

  7. Free-form analysis of the cosmological evolution of radio sources

    International Nuclear Information System (INIS)

    Robertson, J.G.

    1980-01-01

    This paper extends an iterative scheme for calculation of free-form evolution functions able to reconcile observed radio source counts with the standard General Relativistic cosmological models. It is assumed that the luminosity dependence of the evolution consists of a gradual turn-on of evolution above a certain luminosity. No particular functional form is assumed for the redshift dependence of the evolution (i.e. it is free-form). The extension concerns the use of the luminosity distribution to supply an effective luminosity function, thus overcoming a problem of consistency at the high-luminosity end of the luminosity function, where the evolution function has to be known. This method also guarantees that the correct average redshifts will be predicted where they are known observationally at high flux densities. The new iterative scheme has been applied to the source counts at 408 MHz from the Molonglo Cross telescope, using the Einstein-de Sitter cosmology and a recent determination of the luminosity distribution for sources of S 408 > 10 Jy. (author)

  8. Two-step design method for highly compact three-dimensional freeform optical system for LED surface light source.

    Science.gov (United States)

    Mao, Xianglong; Li, Hongtao; Han, Yanjun; Luo, Yi

    2014-10-20

    Designing an illumination system for a surface light source with a strict compactness requirement is quite challenging, especially for the general three-dimensional (3D) case. In accordance with the two key features of an expected illumination distribution, i.e., a well-controlled boundary and a precise illumination pattern, a two-step design method is proposed in this paper for highly compact 3D freeform illumination systems. In the first step, a target shape scaling strategy is combined with an iterative feedback modification algorithm to generate an optimized freeform optical system with a well-controlled boundary of the target distribution. In the second step, a set of selected radii of the system obtained in the first step are optimized to further improve the illuminating quality within the target region. The method is quite flexible and effective to design highly compact optical systems with almost no restriction on the shape of the desired target field. As examples, three highly compact freeform lenses with ratio of center height h of the lens and the maximum dimension D of the source ≤ 2.5:1 are designed for LED surface light sources to form a uniform illumination distribution on a rectangular, a cross-shaped and a complex cross pierced target plane respectively. High light control efficiency of η > 0.7 as well as low relative standard illumination deviation of RSD < 0.07 is obtained simultaneously for all the three design examples.

  9. Progress report on Freeform Calibrations on Coordinate Measureing Machines

    DEFF Research Database (Denmark)

    Savio, Enrico; Meneghello, R.; De Chiffre, Leonardo

    This report is made as a part of the project Easytrac, an EU project under the programme: Competitive and Sustainable Growth: Contract No: G6RD-CT-2000-00188, coordinated by UNIMETRIK S.A. (Spain). The project is concerned with low uncertainty calibrations on coordinate measuring machines...

  10. Design, realization and testing of the nanomefos non-contact measurement machine for freeform optics

    NARCIS (Netherlands)

    Henselmans, R.; Cacace, L.; Rosielle, P.C.J.N.; Steinbuch, M.

    2008-01-01

    By applying freeform optics (figure 1) in high-end optical systems such as used in space, science and lithography applications, system performance can be improved while decreasing the system mass, size and number of required components (for instance [1]). The applicability of classical metrology

  11. Multi-optical-axis measurement of freeform progressive addition lenses using a Hartmann-Shack wavefront sensor

    Science.gov (United States)

    Xiang, Huazhong; Guo, Hang; Fu, Dongxiang; Zheng, Gang; Zhuang, Songlin; Chen, JiaBi; Wang, Cheng; Wu, Jie

    2018-05-01

    To precisely measure the whole-surface characterization of freeform progressive addition lenses (PALs), considering the multi-optical-axis conditions is becoming particularly important. Spherical power and astigmatism (cylinder) measurements for freeform PALs, using a Hartmann-Shack wavefront sensor (HSWFS) are proposed herein. Conversion formulas for the optical performance results were provided as HSWFS Zernike polynomial expansions. For each selected zone, the studied PALs were placed and tilted to simulate the multi-optical-axis conditions. The results of two tested PALs were analyzed using MATLAB programs and represented as contour plots of the spherical equivalent and cylinder of the whole-surface. The proposed experimental setup can provide a high accuracy as well as a possibility of choosing 12 lines and positions of 193 measurement zones on the entire surface. This approach to PAL analysis is potentially an efficient and useful method to objectively evaluate the optical performances, in which the full lens surface is defined and expressed as the contour plots of power in different regions (i.e., the distance region, progressive region, and near region) of the lens for regions of interest.

  12. Fabrication and correction of freeform surface based on Zernike polynomials by slow tool servo

    Science.gov (United States)

    Cheng, Yuan-Chieh; Hsu, Ming-Ying; Peng, Wei-Jei; Hsu, Wei-Yao

    2017-10-01

    Recently, freeform surface widely using to the optical system; because it is have advance of optical image and freedom available to improve the optical performance. For freeform optical fabrication by integrating freeform optical design, precision freeform manufacture, metrology freeform optics and freeform compensate method, to modify the form deviation of surface, due to production process of freeform lens ,compared and provides more flexibilities and better performance. This paper focuses on the fabrication and correction of the free-form surface. In this study, optical freeform surface using multi-axis ultra-precision manufacturing could be upgrading the quality of freeform. It is a machine equipped with a positioning C-axis and has the CXZ machining function which is also called slow tool servo (STS) function. The freeform compensate method of Zernike polynomials results successfully verified; it is correction the form deviation of freeform surface. Finally, the freeform surface are measured experimentally by Ultrahigh Accurate 3D Profilometer (UA3P), compensate the freeform form error with Zernike polynomial fitting to improve the form accuracy of freeform.

  13. A measurement strategy and an error-compensation model for the on-machine laser measurement of large-scale free-form surfaces

    International Nuclear Information System (INIS)

    Li, Bin; Li, Feng; Liu, Hongqi; Cai, Hui; Mao, Xinyong; Peng, Fangyu

    2014-01-01

    This study presents a novel measurement strategy and an error-compensation model for the measurement of large-scale free-form surfaces in on-machine laser measurement systems. To improve the measurement accuracy, the effects of the scan depth, surface roughness, incident angle and azimuth angle on the measurement results were investigated experimentally, and a practical measurement strategy considering the position and orientation of the sensor is presented. Also, a semi-quantitative model based on geometrical optics is proposed to compensate for the measurement error associated with the incident angle. The normal vector of the measurement point is determined using a cross-curve method from the acquired surface data. Then, the azimuth angle and incident angle are calculated to inform the measurement strategy and error-compensation model, respectively. The measurement strategy and error-compensation model are verified through the measurement of a large propeller blade on a heavy machine tool in a factory environment. The results demonstrate that the strategy and the model are effective in increasing the measurement accuracy. (paper)

  14. Freeform Honeycomb Structures

    KAUST Repository

    Jiang, Caigui

    2014-07-01

    Motivated by requirements of freeform architecture, and inspired by the geometry of hexagonal combs in beehives, this paper addresses torsion-free structures aligned with hexagonal meshes. Since repetitive geometry is a very important contribution to the reduction of production costs, we study in detail “honeycomb structures”, which are defined as torsion-free structures where the walls of cells meet at 120 degrees. Interestingly, the Gauss-Bonnet theorem is useful in deriving information on the global distribution of node axes in such honeycombs. This paper discusses the computation and modeling of honeycomb structures as well as applications, e.g. for shading systems, or for quad meshing. We consider this paper as a contribution to the wider topic of freeform patterns, polyhedral or otherwise. Such patterns require new approaches on the technical level, e.g. in the treatment of smoothness, but they also extend our view of what constitutes aesthetic freeform geometry.

  15. Freeform micromachining of an infrared Alvarez lens

    Science.gov (United States)

    Smilie, Paul J.; Dutterer, Brian S.; Lineberger, Jennifer L.; Davies, Matthew A.; Suleski, Thomas J.

    2011-02-01

    In 1967, Luis Alvarez introduced a novel concept for a focusing lens whereby two transmitting elements with cubic polynomial surfaces yield a composite lens of variable focal length with small lateral shifts. Computer simulations have demonstrated the behavior of these devices, but fabricating the refractive cubic surfaces of the types needed with adequate precision and depth modulation has proven to be challenging using standard methods, and, to the authors' knowledge, Alvarez lens elements have not been previously machined in infrared materials. Recent developments in freeform diamond machining capability have enabled the fabrication of such devices. In this paper, we discuss the fabrication of freeform refractive Alvarez elements in germanium using diamond micro-milling on a five-axis Moore Nanotech® 350FG Freeform Generator. Machining approaches are discussed, and measurements of surface figure and finish are presented. Initial experimental tests of optical performance are also discussed.

  16. Paneling architectural freeform surfaces

    KAUST Repository

    Eigensatz, Michael; Kilian, Martin; Schiftner, Alexander; Mitra, Niloy J.; Pottmann, Helmut; Pauly, Mark

    2010-01-01

    The emergence of large-scale freeform shapes in architecture poses big challenges to the fabrication of such structures. A key problem is the approximation of the design surface by a union of patches, socalled panels, that can be manufactured with a

  17. Deployment and evaluation of a dual-sensor autofocusing method for on-machine measurement of patterns of small holes on freeform surfaces.

    Science.gov (United States)

    Chen, Xiaomei; Longstaff, Andrew; Fletcher, Simon; Myers, Alan

    2014-04-01

    This paper presents and evaluates an active dual-sensor autofocusing system that combines an optical vision sensor and a tactile probe for autofocusing on arrays of small holes on freeform surfaces. The system has been tested on a two-axis test rig and then integrated onto a three-axis computer numerical control (CNC) milling machine, where the aim is to rapidly and controllably measure the hole position errors while the part is still on the machine. The principle of operation is for the tactile probe to locate the nominal positions of holes, and the optical vision sensor follows to focus and capture the images of the holes. The images are then processed to provide hole position measurement. In this paper, the autofocusing deviations are analyzed. First, the deviations caused by the geometric errors of the axes on which the dual-sensor unit is deployed are estimated to be 11 μm when deployed on a test rig and 7 μm on the CNC machine tool. Subsequently, the autofocusing deviations caused by the interaction of the tactile probe, surface, and small hole are mathematically analyzed and evaluated. The deviations are a result of the tactile probe radius, the curvatures at the positions where small holes are drilled on the freeform surface, and the effect of the position error of the hole on focusing. An example case study is provided for the measurement of a pattern of small holes on an elliptical cylinder on the two machines. The absolute sum of the autofocusing deviations is 118 μm on the test rig and 144 μm on the machine tool. This is much less than the 500 μm depth of field of the optical microscope. Therefore, the method is capable of capturing a group of clear images of the small holes on this workpiece for either implementation.

  18. Enhanced resolution and accuracy of freeform metrology through Subaperture Stitching Interferometry

    Science.gov (United States)

    Supranowitz, Chris; Maloney, Chris; Murphy, Paul; Dumas, Paul

    2017-10-01

    Recent advances in polishing and metrology have addressed many of the challenges in the fabrication and metrology of freeform surfaces, and the manufacture of these surfaces is possible today. However, achieving the form and mid-spatial frequency (MSF) specifications that are typical of visible imaging systems remains a challenge. Interferometric metrology for freeform surfaces is thus highly desirable for such applications, but the capability is currently quite limited for freeforms. In this paper, we provide preliminary results that demonstrate accurate, high-resolution measurements of freeform surfaces using prototype software on QED's ASI™ (Aspheric Stitching Interferometer).

  19. Paneling architectural freeform surfaces

    KAUST Repository

    Eigensatz, Michael

    2010-07-26

    The emergence of large-scale freeform shapes in architecture poses big challenges to the fabrication of such structures. A key problem is the approximation of the design surface by a union of patches, socalled panels, that can be manufactured with a selected technology at reasonable cost, while meeting the design intent and achieving the desired aesthetic quality of panel layout and surface smoothness. The production of curved panels is mostly based on molds. Since the cost of mold fabrication often dominates the panel cost, there is strong incentive to use the same mold for multiple panels. We cast the major practical requirements for architectural surface paneling, including mold reuse, into a global optimization framework that interleaves discrete and continuous optimization steps to minimize production cost while meeting user-specified quality constraints. The search space for optimization is mainly generated through controlled deviation from the design surface and tolerances on positional and normal continuity between neighboring panels. A novel 6-dimensional metric space allows us to quickly compute approximate inter-panel distances, which dramatically improves the performance of the optimization and enables the handling of complex arrangements with thousands of panels. The practical relevance of our system is demonstrated by paneling solutions for real, cutting-edge architectural freeform design projects. © 2010 ACM.

  20. Paneling architectural freeform surfaces

    KAUST Repository

    Eigensatz, Michael

    2010-07-25

    The emergence of large-scale freeform shapes in architecture poses big challenges to the fabrication of such structures. A key problem is the approximation of the design surface by a union of patches, so-called panels, that can be manufactured with a selected technology at reasonable cost, while meeting the design intent and achieving the desired aesthetic quality of panel layout and surface smoothness. The production of curved panels is mostly based on molds. Since the cost of mold fabrication often dominates the panel cost, there is strong incentive to use the same mold for multiple panels. We cast the major practical requirements for architectural surface paneling, including mold reuse, into a global optimization framework that interleaves discrete and continuous optimization steps to minimize production cost while meeting user-specified quality constraints. The search space for optimization is mainly generated through controlled deviation from the design surface and tolerances on positional and normal continuity between neighboring panels. A novel 6-dimensional metric space allows us to quickly compute approximate inter-panel distances, which dramatically improves the performance of the optimization and enables the handling of complex arrangements with thousands of panels. The practical relevance of our system is demonstrated by paneling solutions for real, cutting-edge architectural freeform design projects.

  1. Geometric Computing for Freeform Architecture

    KAUST Repository

    Wallner, J.; Pottmann, Helmut

    2011-01-01

    Geometric computing has recently found a new field of applications, namely the various geometric problems which lie at the heart of rationalization and construction-aware design processes of freeform architecture. We report on our work in this area

  2. Geometric Rationalization for Freeform Architecture

    KAUST Repository

    Jiang, Caigui

    2016-01-01

    The emergence of freeform architecture provides interesting geometric challenges with regards to the design and manufacturing of large-scale structures. To design these architectural structures, we have to consider two types of constraints. First

  3. ‘Action’ on structured freeform surfaces

    Science.gov (United States)

    Whitehouse, David J.

    2018-06-01

    Surfaces are becoming more complex partly due to the more complicated function required of them and partly due to the introduction of different manufacturing processes. These have thrown into relief the need to consider new ways of measuring and characterizing such surfaces and more importantly to make such characterization more relevant by tying together the geometry and the function more closely. The surfaces which have freeform and structure have been chosen to be a carrier for this investigation because so far there has been little work carried out in this neglected but potentially important area. This necessitates the development of a strategy for their characterization. In this article, some ways have been found of identifying possible strategies for tackling this characterization problem but also linking this characterization to performance and manufacture, based in part on the principles of least action and on the way that nature has evolved to solve the marriage of flexible freeform geometry, structure and function. Recommendations are made for the most suitable surface parameter to use which satisfies the requirement for characterizing structured freeform surfaces as well as utilizing ‘Action’ to predict functionality.

  4. Design of a novel freeform lens for LED uniform illumination and conformal phosphor coating.

    Science.gov (United States)

    Hu, Run; Luo, Xiaobing; Zheng, Huai; Qin, Zong; Gan, Zhiqiang; Wu, Bulong; Liu, Sheng

    2012-06-18

    A conformal phosphor coating can realize a phosphor layer with uniform thickness, which could enhance the angular color uniformity (ACU) of light-emitting diode (LED) packaging. In this study, a novel freeform lens was designed for simultaneous realization of LED uniform illumination and conformal phosphor coating. The detailed algorithm of the design method, which involves an extended light source and double refractions, was presented. The packaging configuration of the LED modules and the modeling of the light-conversion process were also presented. Monte Carlo ray-tracing simulations were conducted to validate the design method by comparisons with a conventional freeform lens. It is demonstrated that for the LED module with the present freeform lens, the illumination uniformity and ACU was 0.89 and 0.9283, respectively. The present freeform lens can realize equivalent illumination uniformity, but the angular color uniformity can be enhanced by 282.3% when compared with the conventional freeform lens.

  5. Design and Fabrication of a Free-Form Reciprocal Roof

    DEFF Research Database (Denmark)

    Parigi, Dario

    2015-01-01

    The paper presents the framework and the design and construction process of a freeform reciprocal pavilion realized during a one-week long workshop with the students of the 1st semester of the Master of Science in Architecture and Design, fall 2014, at Aalborg University. The workshop didactic...... of relations between design parameters and a wide array of measurable performances. Due to the reciprocal structures geometric complexity, the shape generation process is handled using the Reciprocalizer, a software tool developed by the author that embeds in a computational environment the constructional...... logic of reciprocal structures. It enables to engage in real time in iterative processes that allows unfolding the geometric complexity and turn it into a source of inspiration for expanding the design space and triggering the development of unique, adapted and integrated design solutions. Reciprocal...

  6. Validation of calibration procedures for freeform parts on CMMs

    DEFF Research Database (Denmark)

    Savio, Enrico; De Chiffre, Leonardo

    2003-01-01

    The paper describes the validation of a new method for establishment of traceability of freeform measurements on coordinate measuring machines currently being considered for development as a new ISO standard. The method deals with calibration by: i) repeated measurements of a given uncalibrated...

  7. Characterisation of surface roughness for ultra-precision freeform surfaces

    International Nuclear Information System (INIS)

    Li Huifen; Cheung, C F; Lee, W B; To, S; Jiang, X Q

    2005-01-01

    Ultra-precision freeform surfaces are widely used in many advanced optics applications which demand for having surface roughness down to nanometer range. Although a lot of research work has been reported on the study of surface generation, reconstruction and surface characterization such as MOTIF and fractal analysis, most of them are focused on axial symmetric surfaces such as aspheric surfaces. Relative little research work has been found in the characterization of surface roughness in ultra-precision freeform surfaces. In this paper, a novel Robust Gaussian Filtering (RGF) method is proposed for the characterisation of surface roughness for ultra-precision freeform surfaces with known mathematic model or a cloud of discrete points. A series of computer simulation and measurement experiments were conducted to verify the capability of the proposed method. The experimental results were found to agree well with the theoretical results

  8. Freeform lens design for LED collimating illumination.

    Science.gov (United States)

    Chen, Jin-Jia; Wang, Te-Yuan; Huang, Kuang-Lung; Liu, Te-Shu; Tsai, Ming-Da; Lin, Chin-Tang

    2012-05-07

    We present a simple freeform lens design method for an application to LED collimating illumination. The method is derived from a basic geometric-optics analysis and construction approach. By using this method, a highly collimating lens with LED chip size of 1.0 mm × 1.0 mm and optical simulation efficiency of 86.5% under a view angle of ± 5 deg is constructed. To verify the practical performance of the lens, a prototype of the collimator lens is also made, and an optical efficiency of 90.3% with a beam angle of 4.75 deg is measured.

  9. Acylinder and freeform optical manufacturing

    Science.gov (United States)

    Fess, Edward; Wolfs, Frank; DeFisher, Scott; Ross, James

    2015-10-01

    Aspheric cylinders have the ability to improve optical performance over standard cylindrical surfaces. Over the last several years there has also been development into the application and functionality of utilizing freeform surfaces to improve optical performance. Freeforms have the ability to not only improve image quality over a greater field of view, but can open up the design space of an optical system making it more compact. Freeform geometries, much like aspheric cylinders, may not have an axis of rotation to spin the optic about during manufacturing. This leads to costly fabrication processes and custom metrology set ups, which may inhibit their use. Over the last several years, OptiPro Systems has developed and optimized our eSX grinding, UFF and USF polishing, UltraSurf metrology, and ProSurf software programming technologies to make the processing of these complex geometries much easier and deterministic. In this paper we will discuss the challenges associated with manufacturing complex shapes like aspheric cylinders as well as freeform geometries, and how several technologies working together can overcome them. The technologies focus on metrology feedback to a grinding and polishing machine that is controlled through an iterative computer aided manufacturing software system. We will also present examples of these hard to manufacture shapes with results.

  10. Freeform electronics for advanced healthcare

    KAUST Repository

    Hussain, Muhammad Mustafa

    2017-02-16

    Freeform (physically flexible, stretchable and reconfigurable) electronics can be critical enabler for advanced personalized healthcare. With increased global population and extended average lifetime of mankind, it is more important than ever to integrate advanced electronics into our daily life for advanced personalized healthcare. In this paper, we discuss some critical criteria to design such electronics with enabling applications.

  11. Freeform electronics for advanced healthcare

    KAUST Repository

    Hussain, Muhammad Mustafa; Hussain, Aftab M.; Nassar, Joanna M.; Kutbee, Arwa T.; Gumus, Abdurrahman; Hanna, Amir

    2017-01-01

    Freeform (physically flexible, stretchable and reconfigurable) electronics can be critical enabler for advanced personalized healthcare. With increased global population and extended average lifetime of mankind, it is more important than ever to integrate advanced electronics into our daily life for advanced personalized healthcare. In this paper, we discuss some critical criteria to design such electronics with enabling applications.

  12. Freeform optics for photovoltaic concentration

    OpenAIRE

    Benitez Gimenez, Pablo; Miñano Dominguez, Juan Carlos

    2012-01-01

    Freeform surfaces are the key of the state-of-the-art nonimaging optics to solve the challenges in concentration photovoltaics. Different families (FK, XR, FRXI) will be presented, based on the SMS 3D design method and Köhler homogenization.

  13. Partial null astigmatism-compensated interferometry for a concave freeform Zernike mirror

    Science.gov (United States)

    Dou, Yimeng; Yuan, Qun; Gao, Zhishan; Yin, Huimin; Chen, Lu; Yao, Yanxia; Cheng, Jinlong

    2018-06-01

    Partial null interferometry without using any null optics is proposed to measure a concave freeform Zernike mirror. Oblique incidence on the freeform mirror is used to compensate for astigmatism as the main component in its figure, and to constrain the divergence of the test beam as well. The phase demodulated from the partial nulled interferograms is divided into low-frequency phase and high-frequency phase by Zernike polynomial fitting. The low-frequency surface figure error of the freeform mirror represented by the coefficients of Zernike polynomials is reconstructed from the low-frequency phase, applying the reverse optimization reconstruction technology in the accurate model of the interferometric system. The high-frequency surface figure error of the freeform mirror is retrieved from the high-frequency phase adopting back propagating technology, according to the updated model in which the low-frequency surface figure error has been superimposed on the sag of the freeform mirror. Simulations verified that this method is capable of testing a wide variety of astigmatism-dominated freeform mirrors due to the high dynamic range. The experimental result using our proposed method for a concave freeform Zernike mirror is consistent with the null test result employing the computer-generated hologram.

  14. Geometric Rationalization for Freeform Architecture

    KAUST Repository

    Jiang, Caigui

    2016-06-20

    The emergence of freeform architecture provides interesting geometric challenges with regards to the design and manufacturing of large-scale structures. To design these architectural structures, we have to consider two types of constraints. First, aesthetic constraints are important because the buildings have to be visually impressive. Sec- ond, functional constraints are important for the performance of a building and its e cient construction. This thesis contributes to the area of architectural geometry. Specifically, we are interested in the geometric rationalization of freeform architec- ture with the goal of combining aesthetic and functional constraints and construction requirements. Aesthetic requirements typically come from designers and architects. To obtain visually pleasing structures, they favor smoothness of the building shape, but also smoothness of the visible patterns on the surface. Functional requirements typically come from the engineers involved in the construction process. For exam- ple, covering freeform structures using planar panels is much cheaper than using non-planar ones. Further, constructed buildings have to be stable and should not collapse. In this thesis, we explore the geometric rationalization of freeform archi- tecture using four specific example problems inspired by real life applications. We achieve our results by developing optimization algorithms and a theoretical study of the underlying geometrical structure of the problems. The four example problems are the following: (1) The design of shading and lighting systems which are torsion-free structures with planar beams based on quad meshes. They satisfy the functionality requirements of preventing light from going inside a building as shad- ing systems or reflecting light into a building as lighting systems. (2) The Design of freeform honeycomb structures that are constructed based on hex-dominant meshes with a planar beam mounted along each edge. The beams intersect without

  15. Freeform optics: a non-contact "test plate" for manufacturing, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this NASA SBIR Phase I study is to determine the feasibility of measuring precision (fractional wave) freeform optics using non-contact areal (imaging)...

  16. Photon sources for absorptiometric measurements

    International Nuclear Information System (INIS)

    Witt, R.M.; Sandrik, J.M.; Cameron, J.R.

    1976-01-01

    Photon absorptiometry is defined and the requirements of photon sources for these measurements are described. Both x-ray tubes and radionuclide sources are discussed, including the advantages of each in absorptiometric systems

  17. Zometool Rationalization of Freeform Surfaces.

    Science.gov (United States)

    Zimmer, Henrik; Kobbelt, Leif

    2014-10-01

    An ever broader availability of freeform designs together with an increasing demand for product customization has lead to a rising interest in efficient physical realization of such designs, the trend toward personal fabrication. Not only large-scale architectural applications are (becoming increasingly) popular but also different consumer-level rapid-prototyping applications, including toy and 3D puzzle creation. In this work we present a method for do-it-yourself reproduction of freeform designs without the typical limitation of state-of-the-art approaches requiring manufacturing custom parts using semi-professional laser cutters or 3D printers. Our idea is based on a popular mathematical modeling system (Zometool) commonly used for modeling higher dimensional polyhedra and symmetric structures such as molecules and crystal lattices. The proposed method extends the scope of Zometool modeling to freeform, disk-topology surfaces. While being an efficient construction system on the one hand (consisting only of a single node type and nine different edge types), this inherent discreteness of the Zometool system, on the other hand gives rise to a hard approximation problem. We base our method on a marching front approach, where elements are not added in a greedy sense, but rather whole regions on the front are filled optimally, using a set of problem specific heuristics to keep complexity under control.

  18. 3D printed plano-freeform optics for non-coherent discontinuous beam shaping

    Science.gov (United States)

    Assefa, Bisrat G.; Saastamoinen, Toni; Biskop, Joris; Kuittinen, Markku; Turunen, Jari; Saarinen, Jyrki

    2018-06-01

    The design, fabrication, and characterization of freeform optics for LED-based complex target irradiance distribution are challenging. Here, we investigate a 3D printing technology called Printoptical® technology in order to relax or push forward both the fabrication limits and LED-based applications of thick freeform lenses with small slope features. The freeform designs are carried out with an assumption of small-sized LED source using an existing point-source-based Tailoring method, which is available in the semi-commercial software. The numerical methods of the designs are characterized by ray-tracing software. The irradiance patterns of the 3D printed freeform lenses are promising considering the average shape conformity deviation of around ± 40 µm and center area surface roughness around ± 12 nm, which is to our knowledge by far the best result reported for 3D printed freeform lenses with a thickness greater than 1 mm. Applications of freeform lenses with discontinuous target irradiance distribution patterns are expected in eco-friendly energy efficient lighting such as in zebra-cross lighting.

  19. 3D printed plano-freeform optics for non-coherent discontinuous beam shaping

    Science.gov (United States)

    Assefa, Bisrat G.; Saastamoinen, Toni; Biskop, Joris; Kuittinen, Markku; Turunen, Jari; Saarinen, Jyrki

    2018-03-01

    The design, fabrication, and characterization of freeform optics for LED-based complex target irradiance distribution are challenging. Here, we investigate a 3D printing technology called Printoptical® technology in order to relax or push forward both the fabrication limits and LED-based applications of thick freeform lenses with small slope features. The freeform designs are carried out with an assumption of small-sized LED source using an existing point-source-based Tailoring method, which is available in the semi-commercial software. The numerical methods of the designs are characterized by ray-tracing software. The irradiance patterns of the 3D printed freeform lenses are promising considering the average shape conformity deviation of around ± 40 µm and center area surface roughness around ± 12 nm, which is to our knowledge by far the best result reported for 3D printed freeform lenses with a thickness greater than 1 mm. Applications of freeform lenses with discontinuous target irradiance distribution patterns are expected in eco-friendly energy efficient lighting such as in zebra-cross lighting.

  20. T-Spline Based Unifying Registration Procedure for Free-Form Surface Workpieces in Intelligent CMM

    Directory of Open Access Journals (Sweden)

    Zhenhua Han

    2017-10-01

    Full Text Available With the development of the modern manufacturing industry, the free-form surface is widely used in various fields, and the automatic detection of a free-form surface is an important function of future intelligent three-coordinate measuring machines (CMMs. To improve the intelligence of CMMs, a new visual system is designed based on the characteristics of CMMs. A unified model of the free-form surface is proposed based on T-splines. A discretization method of the T-spline surface formula model is proposed. Under this discretization, the position and orientation of the workpiece would be recognized by point cloud registration. A high accuracy evaluation method is proposed between the measured point cloud and the T-spline surface formula. The experimental results demonstrate that the proposed method has the potential to realize the automatic detection of different free-form surfaces and improve the intelligence of CMMs.

  1. Solid freeform fabrication of biomaterials

    Science.gov (United States)

    Chu, Tien-Min Gabriel

    1999-12-01

    The biological performance of porous Hydroxyapatite (HA) is closely related to the pore architecture in the implants. The study on the effect of architecture to the biological performance of porous HA requires new manufacturing methods that can fabricate implants with controlled pores channels. In this thesis, four highly loaded HA and alumina suspensions were formulated and three different processes involving Solid Freeform Fabrication (SFF) were developed. An aqueous HA suspension in acrylamides was first formulated and the UV-curing properties were evaluated. With a medical grade HA powder, two non-aqueous HA suspensions were formulated: a 40 vol.% HA suspension in Hexanediol Diacrylate (HDDA) and a 40 vol.% HA suspension in 1:1 mix of Propoxylated Neopentyl Glycol Diacrylate (PNPGDA) and Isobomyl Acrylate (EBA). A 50 vol.% Alumina suspension in PNPGDA/IBA was also formulated. The effect of dispersant to the viscosity of the suspensions was characterized. In the Stereolithography (SL) method, the curing parameters of HA/HDDA and HA/PNPGDA/IBA were determined. Prototype HA implants with 1,700 mum internal channels were built directly on an SL Apparatus (SLA). The designed internal channel patterns were preserved after sintering. In the Ink-jet printing method, the high temperature flow behaviors of the suspensions were characterized. The effects of solids loading to the viscosity of the suspensions were modeled with Krieger-Dougherty equation. Leveling theory developed in paint industry was employed to analyze the self-leveling capability of the suspensions. In the indirect SL method, the thermal curing behavior of HA and alumina suspensions were characterized. The total cure time was measured and the curing kinetics was modeled. Negative molds for the implants were designed and built on SLA with epoxy resin. HA/PNPGDA/IBA was cast into the mold and cured in an oven. The binders and the epoxy mold were pyrolyzed and the green bodies sintered. Internal channels

  2. Freeform aberrations in phase space: an example.

    Science.gov (United States)

    Babington, James

    2017-06-01

    We consider how optical propagation and aberrations of freeform systems can be formulated in phase space. As an example system, a freeform prism is analyzed and discussed. Symmetry considerations and their group theory descriptions are given some importance. Numerical aberrations are also highlighted and put into the context of the underlying aberration theory.

  3. Freeform surface descriptions. Part I: Mathematical representations

    Science.gov (United States)

    Broemel, Anika; Lippmann, Uwe; Gross, Herbert

    2017-10-01

    Optical systems can benefit strongly from freeform surfaces; however, the choice of the right surface representation is not trivial and many aspects must be considered. In this work, we discuss the general approach classical globally defined representations, as well as the basic mathematics and properties of the most commonly used descriptions and present a new description developed by us for describing freeform surfaces.

  4. Geometric Computing for Freeform Architecture

    KAUST Repository

    Wallner, J.

    2011-06-03

    Geometric computing has recently found a new field of applications, namely the various geometric problems which lie at the heart of rationalization and construction-aware design processes of freeform architecture. We report on our work in this area, dealing with meshes with planar faces and meshes which allow multilayer constructions (which is related to discrete surfaces and their curvatures), triangles meshes with circle-packing properties (which is related to conformal uniformization), and with the paneling problem. We emphasize the combination of numerical optimization and geometric knowledge.

  5. Non-uniformly sampled grids in double pole coordinate system for freeform reflector construction

    Science.gov (United States)

    Ma, Donglin; Pacheco, Shaun; Feng, Zexin; Liang, Rongguang

    2015-08-01

    We propose a new method to design freeform reflectors by nonuniformly sampling the source intensity distribution in double pole coordinate system. In double pole coordinate system, there is no pole for the whole hemisphere because both poles of the spherical coordinate system are moved to southernmost point of the sphere and overlapped together. With symmetric definition of both angular coordinates in the modified double pole coordinate system, a better match between the source intensity distribution and target irradiance distribution can be achieved for reflectors with large acceptance solid angle, leading to higher light efficiency and better uniformity on the target surface. With non-uniform sampling of the source intensity, we can design circular freeform reflector to obtain uniform rectangular illumination pattern. Aided by the feedback optimization, the freeform reflector can achieve the collection efficiency for ideal point source over 0.7 and relative standard deviation (RSD) less than 0.1.

  6. Advances in the production of freeform optical surfaces

    Science.gov (United States)

    Tohme, Yazid E.; Luniya, Suneet S.

    2007-05-01

    Recent market demands for free-form optics have challenged the industry to find new methods and techniques to manufacture free-form optical surfaces with a high level of accuracy and reliability. Production techniques are becoming a mix of multi-axis single point diamond machining centers or deterministic ultra precision grinding centers coupled with capable measurement systems to accomplish the task. It has been determined that a complex software tool is required to seamlessly integrate all aspects of the manufacturing process chain. Advances in computational power and improved performance of computer controlled precision machinery have driven the use of such software programs to measure, visualize, analyze, produce and re-validate the 3D free-form design thus making the process of manufacturing such complex surfaces a viable task. Consolidation of the entire production cycle in a comprehensive software tool that can interact with all systems in design, production and measurement phase will enable manufacturers to solve these complex challenges providing improved product quality, simplified processes, and enhanced performance. The work being presented describes the latest advancements in developing such software package for the entire fabrication process chain for aspheric and free-form shapes. It applies a rational B-spline based kernel to transform an optical design in the form of parametrical definition (optical equation), standard CAD format, or a cloud of points to a central format that drives the simulation. This software tool creates a closed loop for the fabrication process chain. It integrates surface analysis and compensation, tool path generation, and measurement analysis in one package.

  7. Four-Mirror Freeform Reflective Imaging Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — Central Objectives: The research involves a revelation of the solution space for revolutionary families of four-mirror freeform reflective imaging systems. A...

  8. Functional webs for freeform architecture

    KAUST Repository

    Deng, Bailin

    2011-08-01

    Rationalization and construction-aware design dominate the issue of realizability of freeform architecture. The former means the decomposition of an intended shape into parts which are sufficiently simple and efficient to manufacture; the latter refers to a design procedure which already incorporates rationalization. Recent contributions to this topic have been concerned mostly with small-scale parts, for instance with planar faces of meshes. The present paper deals with another important aspect, namely long-range parts and supporting structures. It turns out that from the pure geometry viewpoint this means studying families of curves which cover surfaces in certain well-defined ways. Depending on the application one has in mind, different combinatorial arrangements of curves are required. We here restrict ourselves to so-called hexagonal webs which correspond to a triangular or tri-hex decomposition of a surface. The individual curve may have certain special properties, like being planar, being a geodesic, or being part of a circle. Each of these properties is motivated by manufacturability considerations and imposes constraints on the shape of the surface. We investigate the available degrees of freedom, show numerical methods of optimization, and demonstrate the effectivity of our approach and the variability of construction solutions derived from webs by means of actual architectural designs.

  9. Null testing of nonrotational symmetry transmission optical freeform: design, modeling, and inspection on the basis of Fermat principles

    Science.gov (United States)

    Qiu, Gufeng; Cui, Xudong

    2015-11-01

    We present a general design method for a type of transmission freeforms without rotational symmetry and achieve the null testing by putting a well-designed Fermat reflector on the transmitting optical path. The design principle of the reflector is given, and an eccentric spherical surface with 1-mm deviation is used as an example of testing freeform. We fabricated the reflector and the freeform with the single-point diamond turning machine. Both conventional interference inspection and our approach give consistent results. The design error is less than 106 mm, and the measurement accuracy is nearly completely determined by the fabrication precision. This approach can also be applied to the inspections of reflecting freeforms with low costs.

  10. Design a freeform microlens array module for any arbitrary-shape collimated beam shaping and color mixing

    Science.gov (United States)

    Chen, Enguo; Wu, Rengmao; Guo, Tailiang

    2014-06-01

    Collimated beam shaping with freeform surface usually employs a predefined mapping to tailor one or multiple freeform surfaces. Limitation on those designs is that the source, the freeform optics and the target are in fixed one-to-one correspondence with each other. To overcome this drawback, this paper presents a kind of freeform microlens array module integrated with an ultra-thin freeform microlens array and a condenser lens to reshape any arbitrary-shape collimated beam into a prescribed uniform rectangular illumination and achieve color mixing. The design theory is explicitly given, and some key issues are addressed. Several different application examples are given, and the target is obtained with high uniformity and energy efficiency. This freeform microlens array module, which shows better flexibility and practicality than the regular designs, can be used not only to reshape any arbitrary-shape collimated beam (or a collimated beam integrated with several sub-collimated beams), but also most importantly to achieve color mixing. With excellent optical performance and ultra-compact volume, this optical module together with the design theory can be further introduced into other applications and will have a huge market potential in the near future.

  11. Nodal aberration theory applied to freeform surfaces

    Science.gov (United States)

    Fuerschbach, Kyle; Rolland, Jannick P.; Thompson, Kevin P.

    2014-12-01

    When new three-dimensional packages are developed for imaging optical systems, the rotational symmetry of the optical system is often broken, changing its imaging behavior and making the optical performance worse. A method to restore the performance is to use freeform optical surfaces that compensate directly the aberrations introduced from tilting and decentering the optical surfaces. In order to effectively optimize the shape of a freeform surface to restore optical functionality, it is helpful to understand the aberration effect the surface may induce. Using nodal aberration theory the aberration fields induced by a freeform surface in an optical system are explored. These theoretical predications are experimentally validated with the design and implementation of an aberration generating telescope.

  12. Towards Free-Form Kinetic Structures

    DEFF Research Database (Denmark)

    Parigi, Dario; Kirkegaard, Poul Henning

    2012-01-01

    of pin-slot paths starting from the local displacements of element [2] [3]. In the design of kinetic structures, in particular when complex three dimensional and non regular configurations are involved, the functionality is frequently related to a global displacement capability of the assembly rather...... for the generation of free-form kinetic structures....

  13. Detection and reconstruction of freeform sweeps

    KAUST Repository

    Barton, Michael; Pottmann, Helmut; Wallner, Johannes

    2014-01-01

    We study the difficult problem of deciding if parts of a freeform surface can be generated, or approximately generated, by the motion of a planar profile through space. While this task is basic for understanding the geometry of shapes as well

  14. Freeform optics applications in photovoltaic concentration

    OpenAIRE

    Miñano Dominguez, Juan Carlos; Benitez Gimenez, Pablo; Zamora Herranz, Pablo; Mendes Lopes, Joao; Buljan, Marina; Santamaria Galdon, Maria Asuncion

    2012-01-01

    Freeform surfaces are the key of the state-of-the-art nonimaging optics to solve the challenges in concentration photovoltaics. Different families (FK, XR, FRXI) will be presented, based on the SMS 3D design method and Köhler homogenization.

  15. Worthwhile optical method for free-form mirrors qualification

    Science.gov (United States)

    Sironi, G.; Canestrari, R.; Toso, G.; Pareschi, G.

    2013-09-01

    We present an optical method for free-form mirrors qualification developed by the Italian National Institute for Astrophysics (INAF) in the context of the ASTRI (Astrofisica con Specchi a Tecnologia Replicante Italiana) Project which includes, among its items, the design, development and installation of a dual-mirror telescope prototype for the Cherenkov Telescope Array (CTA) observatory. The primary mirror panels of the telescope prototype are free-form concave mirrors with few microns accuracy required on the shape error. The developed technique is based on the synergy between a Ronchi-like optical test performed on the reflecting surface and the image, obtained by means of the TraceIT ray-tracing proprietary code, a perfect optics should generate in the same configuration. This deflectometry test allows the reconstruction of the slope error map that the TraceIT code can process to evaluate the measured mirror optical performance at the telescope focus. The advantages of the proposed method is that it substitutes the use of 3D coordinates measuring machine reducing production time and costs and offering the possibility to evaluate on-site the mirror image quality at the focus. In this paper we report the measuring concept and compare the obtained results to the similar ones obtained processing the shape error acquired by means of a 3D coordinates measuring machine.

  16. 3D freeform printing of silk fibroin.

    Science.gov (United States)

    Rodriguez, Maria J; Dixon, Thomas A; Cohen, Eliad; Huang, Wenwen; Omenetto, Fiorenzo G; Kaplan, David L

    2018-04-15

    Freeform fabrication has emerged as a key direction in printing biologically-relevant materials and structures. With this emerging technology, complex structures with microscale resolution can be created in arbitrary geometries and without the limitations found in traditional bottom-up or top-down additive manufacturing methods. Recent advances in freeform printing have used the physical properties of microparticle-based granular gels as a medium for the submerged extrusion of bioinks. However, most of these techniques require post-processing or crosslinking for the removal of the printed structures (Miller et al., 2015; Jin et al., 2016) [1,2]. In this communication, we introduce a novel method for the one-step gelation of silk fibroin within a suspension of synthetic nanoclay (Laponite) and polyethylene glycol (PEG). Silk fibroin has been used as a biopolymer for bioprinting in several contexts, but chemical or enzymatic additives or bulking agents are needed to stabilize 3D structures. Our method requires no post-processing of printed structures and allows for in situ physical crosslinking of pure aqueous silk fibroin into arbitrary geometries produced through freeform 3D printing. 3D bioprinting has emerged as a technology that can produce biologically relevant structures in defined geometries with microscale resolution. Techniques for fabrication of free-standing structures by printing into granular gel media has been demonstrated previously, however, these methods require crosslinking agents and post-processing steps on printed structures. Our method utilizes one-step gelation of silk fibroin within a suspension of synthetic nanoclay (Laponite), with no need for additional crosslinking compounds or post processing of the material. This new method allows for in situ physical crosslinking of pure aqueous silk fibroin into defined geometries produced through freeform 3D printing. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights

  17. Compact illumination optic with three freeform surfaces for improved beam control.

    Science.gov (United States)

    Sorgato, Simone; Mohedano, Rubén; Chaves, Julio; Hernández, Maikel; Blen, José; Grabovičkić, Dejan; Benítez, Pablo; Miñano, Juan Carlos; Thienpont, Hugo; Duerr, Fabian

    2017-11-27

    Multi-chip and large size LEDs dominate the lighting market in developed countries these days. Nevertheless, a general optical design method to create prescribed intensity patterns for this type of extended sources does not exist. We present a design strategy in which the source and the target pattern are described by means of "edge wavefronts" of the system. The goal is then finding an optic coupling these wavefronts, which in the current work is a monolithic part comprising up to three freeform surfaces calculated with the simultaneous multiple surface (SMS) method. The resulting optic fully controls, for the first time, three freeform wavefronts, one more than previous SMS designs. Simulations with extended LEDs demonstrate improved intensity tailoring capabilities, confirming the effectiveness of our method and suggesting that enhanced performance features can be achieved by controlling additional wavefronts.

  18. Imaging Freeform Optical Systems Designed with NURBS Surfaces

    Science.gov (United States)

    2015-12-01

    reflective, anastigmat 1 Introduction The imaging freeform optical systems described here are designed using non-uniform rational basis-spline (NURBS...code, but to succeed in designing NURBS freeform optical systems an optimization code is required. The motivation for developing the optical design

  19. Synthesis of freeform refractive surfaces forming various radiation patterns using interpolation

    Science.gov (United States)

    Voznesenskaya, Anna; Mazur, Iana; Krizskiy, Pavel

    2017-09-01

    Optical freeform surfaces are very popular today in such fields as lighting systems, sensors, photovoltaic concentrators, and others. The application of such surfaces allows to obtain systems with a new quality with a reduced number of optical components to ensure high consumer characteristics: small size, weight, high optical transmittance. This article presents the methods of synthesis of refractive surface for a given source and the radiation pattern of various shapes using a computer simulation cubic spline interpolation.

  20. Automated inspection of gaps on the free-form shape parts by laser scanning technologies

    Science.gov (United States)

    Zhou, Sen; Xu, Jian; Tao, Lei; An, Lu; Yu, Yan

    2018-01-01

    In industrial manufacturing processes, the dimensional inspection of the gaps on the free-form shape parts is critical and challenging, and is directly associated with subsequent assembly and terminal product quality. In this paper, a fast measuring method for automated gap inspection based on laser scanning technologies is presented. The proposed measuring method consists of three steps: firstly, the relative position is determined according to the geometric feature of measuring gap, which considers constraints existing in a laser scanning operation. Secondly, in order to acquire a complete gap profile, a fast and effective scanning path is designed. Finally, the range dimension of the gaps on the free-form shape parts including width, depth and flush, correspondingly, is described in a virtual environment. In the future, an appliance machine based on the proposed method will be developed for the on-line dimensional inspection of gaps on the automobile or aerospace production line.

  1. Integrated manufacture of a freeform off-axis multi-reflective imaging system without optical alignment.

    Science.gov (United States)

    Li, Zexiao; Liu, Xianlei; Fang, Fengzhou; Zhang, Xiaodong; Zeng, Zhen; Zhu, Linlin; Yan, Ning

    2018-03-19

    Multi-reflective imaging systems find wide applications in optical imaging and space detection. However, it is faced with difficulties in adjusting the freeform mirrors with high accuracy to guarantee the optical function. Motivated by this, an alignment-free manufacture approach is proposed to machine the optical system. The direct optical performance-guided manufacture route is established without measuring the form error of freeform optics. An analytical model is established to investigate the effects of machine errors to serve the error identification and compensation in machining. Based on the integrated manufactured system, an ingenious self-designed testing configuration is constructed to evaluate the optical performance by directly measuring the wavefront aberration. Experiments are carried out to manufacture a three-mirror anastigmat, surface topographical details and optical performance shows agreement to the designed expectation. The final system works as an off-axis infrared imaging system. Results validate the feasibility of the proposed method to achieve excellent optical application.

  2. Detection and reconstruction of freeform sweeps

    KAUST Repository

    Barton, Michael

    2014-05-01

    We study the difficult problem of deciding if parts of a freeform surface can be generated, or approximately generated, by the motion of a planar profile through space. While this task is basic for understanding the geometry of shapes as well as highly relevant for manufacturing and building construction, previous approaches were confined to special cases like kinematic surfaces or "moulding" surfaces. The general case remained unsolved so far. We approach this problem by a combination of local and global methods: curve analysis with regard to "movability", curve comparison by common substring search in curvature plots, an exhaustive search through all planar cuts enhanced by quick rejection procedures, the ordering of candidate profiles and finally, global optimization. The main applications of our method are digital reconstruction of CAD models exhibiting sweep patches, and aiding in manufacturing freeform surfaces by pointing out those parts which can be approximated by sweeps. © 2014 The Author(s) Computer Graphics Forum © 2014 The Eurographics Association and John Wiley & Sons Ltd. Published by John Wiley & Sons Ltd.

  3. Measuring radon source magnitude in residential buildings

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Boegel, M.L.; Nero, A.V.

    1981-08-01

    A description is given of procedures used in residences for rapid grab-sample and time-dependent measurements of the air-exchange rate and radon concentration. The radon source magnitude is calculated from the results of simultaneous measurements of these parameters. Grab-sample measurements in three survey groups comprising 101 US houses showed the radon source magnitude to vary approximately log-normally with a geometric mean of 0.37 and a range of 0.01 to 6.0 pCi 1 -1 h -1 . Successive measurements in six houses in the northeastern United States showed considerable variability in source magnitude within a given house. In two of these houses the source magnitude showed a strong correlation with the air-exchange rate, suggesting that soil gas influx can be an important transport process for indoor radon

  4. Design and evaluation of a freeform lens by using a method of luminous intensity mapping and a differential equation

    Science.gov (United States)

    Essameldin, Mahmoud; Fleischmann, Friedrich; Henning, Thomas; Lang, Walter

    2017-02-01

    Freeform optical systems are playing an important role in the field of illumination engineering for redistributing the light intensity, because of its capability of achieving accurate and efficient results. The authors have presented the basic idea of the freeform lens design method at the 117th annual meeting of the German Society of Applied Optics (DGAOProceedings). Now, we demonstrate the feasibility of the design method by designing and evaluating a freeform lens. The concepts of luminous intensity mapping, energy conservation and differential equation are combined in designing a lens for non-imaging applications. The required procedures to design a lens including the simulations are explained in detail. The optical performance is investigated by using a numerical simulation of optical ray tracing. For evaluation, the results are compared with another recently published design method, showing the accurate performance of the proposed method using a reduced number of mapping angles. As a part of the tolerance analyses of the fabrication processes, the influence of the light source misalignments (translation and orientation) on the beam-shaping performance is presented. Finally, the importance of considering the extended light source while designing a freeform lens using the proposed method is discussed.

  5. Cartesian oval representation of freeform optics in illumination systems.

    Science.gov (United States)

    Michaelis, D; Schreiber, P; Bräuer, A

    2011-03-15

    The geometrical method for constructing optical surfaces for illumination purpose developed by Oliker and co-workers [Trends in Nonlinear Analysis (Springer, 2003)] is generalized in order to obtain freeform designs in arbitrary optical systems. The freeform is created by a set of primitive surface elements, which are generalized Cartesian ovals adapted to the given optical system. Those primitives are determined by Hamiltonian theory of ray optics. The potential of this approach is demonstrated by some examples, e.g., freeform lenses with collimating front elements.

  6. Solid Freeform Fabrication Proceedings -1999

    Science.gov (United States)

    1999-08-11

    with a Coordinate Measuring Machine Irenee Tyvaerf, Georges Fader, Emannuelle Rouhaud", "Universite de Technologie de Troyes , bClemson University...de Troyes , France Prof. Georges Fadel, Clemson University Prof. Emannuelle Rouhaud, Universite de Technologie de Troyes , France Abstract Industries

  7. Measurements of magnetic field sources in schools

    International Nuclear Information System (INIS)

    Johnson, G.B.

    1992-01-01

    The Electrical Systems Division of the Electric Power Research Institute (EPRI) has initiated several research projects to investigate magnetic field levels, their characteristics, and their sources. This paper describes measurements of magnetic field sources in schools. Magnetic field measurements were made at four schools in the service areas of two utility companies. Magnetic field measurements included profiles of the magnetic field versus distance near power lines, around the perimeter of the school buildings, and at several locations within each school. Twenty-four hour measurements were also made to record the temporal variation of the magnetic field at several locations at each school. The instrumentation, measurement techniques, and magnetic field sources identified are discussed

  8. Virtual-stereo fringe reflection technique for specular free-form surface testing

    Science.gov (United States)

    Ma, Suodong; Li, Bo

    2016-11-01

    Due to their excellent ability to improve the performance of optical systems, free-form optics have attracted extensive interest in many fields, e.g. optical design of astronomical telescopes, laser beam expanders, spectral imagers, etc. However, compared with traditional simple ones, testing for such kind of optics is usually more complex and difficult which has been being a big barrier for the manufacture and the application of these optics. Fortunately, owing to the rapid development of electronic devices and computer vision technology, fringe reflection technique (FRT) with advantages of simple system structure, high measurement accuracy and large dynamic range is becoming a powerful tool for specular free-form surface testing. In order to obtain absolute surface shape distributions of test objects, two or more cameras are often required in the conventional FRT which makes the system structure more complex and the measurement cost much higher. Furthermore, high precision synchronization between each camera is also a troublesome issue. To overcome the aforementioned drawback, a virtual-stereo FRT for specular free-form surface testing is put forward in this paper. It is able to achieve absolute profiles with the help of only one single biprism and a camera meanwhile avoiding the problems of stereo FRT based on binocular or multi-ocular cameras. Preliminary experimental results demonstrate the feasibility of the proposed technique.

  9. Additive manufacturing for freeform mechatronics design: from concepts to applications

    NARCIS (Netherlands)

    Baars, G. van; Smeltink, J.; Werff, J. van der; Limpens, M.; Barink, M.; Berg, D. van den; Vreugd, J. de; Witvoet, G.; Galaktionov, O.S.

    2015-01-01

    This article presents developments of freeform mechatronics concepts, enabled by industrial Additive Manufacturing (AM), aiming at breakthroughs for precision engineering challenges such as lightweight, advanced thermal control, and integrated design. To assess potential impact in future

  10. High dose rate brachytherapy source measurement intercomparison.

    Science.gov (United States)

    Poder, Joel; Smith, Ryan L; Shelton, Nikki; Whitaker, May; Butler, Duncan; Haworth, Annette

    2017-06-01

    This work presents a comparison of air kerma rate (AKR) measurements performed by multiple radiotherapy centres for a single HDR 192 Ir source. Two separate groups (consisting of 15 centres) performed AKR measurements at one of two host centres in Australia. Each group travelled to one of the host centres and measured the AKR of a single 192 Ir source using their own equipment and local protocols. Results were compared to the 192 Ir source calibration certificate provided by the manufacturer by means of a ratio of measured to certified AKR. The comparisons showed remarkably consistent results with the maximum deviation in measurement from the decay-corrected source certificate value being 1.1%. The maximum percentage difference between any two measurements was less than 2%. The comparisons demonstrated the consistency of well-chambers used for 192 Ir AKR measurements in Australia, despite the lack of a local calibration service, and served as a valuable focal point for the exchange of ideas and dosimetry methods.

  11. Geometric Modeling and Reasoning of Human-Centered Freeform Products

    CERN Document Server

    Wang, Charlie C L

    2013-01-01

    The recent trend in user-customized product design requires the shape of products to be automatically adjusted according to the human body’s shape, so that people will feel more comfortable when wearing these products.  Geometric approaches can be used to design the freeform shape of products worn by people, which can greatly improve the efficiency of design processes in various industries involving customized products (e.g., garment design, toy design, jewel design, shoe design, and design of medical devices, etc.). These products are usually composed of very complex geometric shapes (represented by free-form surfaces), and are not driven by a parameter table but a digital human model with free-form shapes or part of human bodies (e.g., wrist, foot, and head models).   Geometric Modeling and Reasoning of Human-Centered Freeform Products introduces the algorithms of human body reconstruction, freeform product modeling, constraining and reconstructing freeform products, and shape optimization for improving...

  12. Reconstruction of freeform surfaces for metrology

    International Nuclear Information System (INIS)

    El-Hayek, N; Nouira, H; Anwer, N; Damak, M; Gibaru, O

    2014-01-01

    The application of freeform surfaces has increased since their complex shapes closely express a product's functional specifications and their machining is obtained with higher accuracy. In particular, optical surfaces exhibit enhanced performance especially when they take aspheric forms or more complex forms with multi-undulations. This study is mainly focused on the reconstruction of complex shapes such as freeform optical surfaces, and on the characterization of their form. The computer graphics community has proposed various algorithms for constructing a mesh based on the cloud of sample points. The mesh is a piecewise linear approximation of the surface and an interpolation of the point set. The mesh can further be processed for fitting parametric surfaces (Polyworks ® or Geomagic ® ). The metrology community investigates direct fitting approaches. If the surface mathematical model is given, fitting is a straight forward task. Nonetheless, if the surface model is unknown, fitting is only possible through the association of polynomial Spline parametric surfaces. In this paper, a comparative study carried out on methods proposed by the computer graphics community will be presented to elucidate the advantages of these approaches. We stress the importance of the pre-processing phase as well as the significance of initial conditions. We further emphasize the importance of the meshing phase by stating that a proper mesh has two major advantages. First, it organizes the initially unstructured point set and it provides an insight of orientation, neighbourhood and curvature, and infers information on both its geometry and topology. Second, it conveys a better segmentation of the space, leading to a correct patching and association of parametric surfaces

  13. Accurate shear measurement with faint sources

    International Nuclear Information System (INIS)

    Zhang, Jun; Foucaud, Sebastien; Luo, Wentao

    2015-01-01

    For cosmic shear to become an accurate cosmological probe, systematic errors in the shear measurement method must be unambiguously identified and corrected for. Previous work of this series has demonstrated that cosmic shears can be measured accurately in Fourier space in the presence of background noise and finite pixel size, without assumptions on the morphologies of galaxy and PSF. The remaining major source of error is source Poisson noise, due to the finiteness of source photon number. This problem is particularly important for faint galaxies in space-based weak lensing measurements, and for ground-based images of short exposure times. In this work, we propose a simple and rigorous way of removing the shear bias from the source Poisson noise. Our noise treatment can be generalized for images made of multiple exposures through MultiDrizzle. This is demonstrated with the SDSS and COSMOS/ACS data. With a large ensemble of mock galaxy images of unrestricted morphologies, we show that our shear measurement method can achieve sub-percent level accuracy even for images of signal-to-noise ratio less than 5 in general, making it the most promising technique for cosmic shear measurement in the ongoing and upcoming large scale galaxy surveys

  14. Radon measurements: the sources of uncertainties

    International Nuclear Information System (INIS)

    Zhukovsky, Michael; Onischenko, Alexandra; Bastrikov, Vladislav

    2008-01-01

    Full text: Radon measurements are quite complicated process and the correct estimation of uncertainties is very important. The sources of uncertainties for grab sampling, short term measurements (charcoal canisters), long term measurements (track detectors) and retrospective measurements (surface traps) are analyzed. The main sources of uncertainties for grab sampling measurements are: systematic bias of reference equipment; random Poisson and non-Poisson errors during calibration; random Poisson and non-Poisson errors during measurements. These sources are also common both for short term measurements (charcoal canisters) and long term measurements (track detectors). Usually during the calibration the high radon concentrations are used (1-5 kBq/m 3 ) and the Poisson random error rarely exceed some percents. Nevertheless the dispersion of measured values even during the calibration usually exceeds the Poisson dispersion expected on the basis of counting statistic. The origins of such non-Poisson random errors during calibration are different for different kinds of instrumental measurements. At present not all sources of non-Poisson random errors are trustworthy identified. The initial calibration accuracy of working devices rarely exceeds the value 20%. The real radon concentrations usually are in the range from some tens to some hundreds Becquerel per cubic meter and for low radon levels Poisson random error can reach up to 20%. The random non-Poisson errors and residual systematic biases are depends on the kind of measurement technique and the environmental conditions during radon measurements. For charcoal canisters there are additional sources of the measurement errors due to influence of air humidity and the variations of radon concentration during the canister exposure. The accuracy of long term measurements by track detectors will depend on the quality of chemical etching after exposure and the influence of season radon variations. The main sources of

  15. Calorimetric measurement of strong γ emitting sources

    International Nuclear Information System (INIS)

    Brangier, B.; Herczeg, C.; Henry, R.

    1968-01-01

    This publication gives the principle and a description of an adiabatic calorimeter for measuring the real activity of strong gamma-emitting sources by absorbing the emitted energy in a mass of copper. Because of the difficulty of evaluating the amount self- absorption, we have built a calorimeter for measuring the self- absorption, and a description of it is given.The results of these three measurements are fairly satisfactory. The calibration and the actual measurements obtained are given with a few corrections made necessary by the design of the apparatus. The correlation of the various results is discussed. (author) [fr

  16. Beam emittance measurements on multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Lee, Y.; Leung, K.N. [and others

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 {mu}m patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma.

  17. Beam emittance measurements on multicusp ion sources

    International Nuclear Information System (INIS)

    Sarstedt, M.; Lee, Y.; Leung, K.N.

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 μm patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma

  18. Precision reconstruction of manufactured free-form components

    Science.gov (United States)

    Ristic, Mihailo; Brujic, Djordje; Ainsworth, Iain

    2000-03-01

    Manufacturing needs in many industries, especially the aerospace and the automotive, involve CAD remodeling of manufactured free-form parts using NURBS. This is typically performed as part of 'first article inspection' or 'closing the design loop.' The reconstructed model must satisfy requirements such as accuracy, compatibility with the original CAD model and adherence to various constraints. The paper outlines a methodology for realizing this task. Efficiency and quality of the results are achieved by utilizing the nominal CAD model. It is argued that measurement and remodeling steps are equally important. We explain how the measurement was optimized in terms of accuracy, point distribution and measuring speed using a CMM. Remodeling steps include registration, data segmentation, parameterization and surface fitting. Enforcement of constraints such as continuity was performed as part of the surface fitting process. It was found necessary that the relevant algorithms are able to perform in the presence of measurement noise, while making no special assumptions about regularity of data distribution. In order to deal with real life situations, a number of supporting functions for geometric modeling were required and these are described. The presented methodology was applied using real aeroengine parts and the experimental results are presented.

  19. High Brightness HDR Projection Using Dynamic Freeform Lensing

    KAUST Repository

    Damberg, Gerwin

    2016-05-03

    Cinema projectors need to compete with home theater displays in terms of image quality. High frame rate and spatial resolution as well as stereoscopic 3D are common features today, but even the most advanced cinema projectors lack in-scene contrast and, more important, high peak luminance, both of which are essential perceptual attributes of images appearing realistic. At the same time, HDR image statistics suggest that the average image intensity in a controlled ambient viewing environment such as the cinema can be as low as 1% for cinematic HDR content and not often higher than 18%, middle gray in photography. Traditional projection systems form images and colors by blocking the source light from a lamp, therefore attenuating between 99% and 82% of light, on average. This inefficient use of light poses significant challenges for achieving higher peak brightness levels. In this work, we propose a new projector architecture built around commercially available components, in which light can be steered to form images. The gain in system efficiency significantly reduces the total cost of ownership of a projector (fewer components and lower operating cost), and at the same time increases peak luminance and improves black level beyond what is practically achievable with incumbent projector technologies. At the heart of this computational display technology is a new projector hardware design using phase modulation in combination with a new optimization algorithm that is capable of on-the-fly computation of freeform lens surfaces. © 2016 ACM.

  20. Solid freeform fabrication of biological materials

    Science.gov (United States)

    Wang, Jiwen

    This thesis investigates solid freeform fabrication of biological materials for dental restoration and orthopedic implant applications. The basic approach in this study for solid freeform fabrication of biological materials is micro-extrusion of single or multiple slurries for 3D components and inkjet color printing of multiple suspensions for functionally graded materials (FGMs). Common issues associated with micro-extrusion and inkjet color printing are investigated. These common issues include (i) formulation of stable slurries with a pseudoplastic property, (ii) cross-sectional geometry of the extrudate as a function of the extrusion parameters, (iii) fabrication path optimization for extrusion process, (iv) extrusion optimization for multi-layer components, (v) composition control in functionally graded materials, and (vi) sintering optimization to convert the freeform fabricated powder compact to a dense body for biological applications. The present study clearly shows that the rheological and extrusion behavior of dental porcelain slurries depend strongly on the pH value of the slurry and extrusion conditions. A slurry with pseudoplastic properties is a basic requirement for obtaining extruded lines with rectangular cross-sections. The cross-sectional geometry of the extrudate is also strongly affected by extrusion parameters including the extrusion nozzle height, nozzle moving speed, extrusion rate, and critical nozzle height. Proper combinations of these extrusion parameters are necessary in order to obtain single line extrudates with near rectangular cross-sections and 3D objects with dimensional accuracy, uniform wall thickness, good wall uprightness, and no wall slumping. Based on these understandings, single-wall, multi-wall, and solid teeth have been fabricated via micro-extrusion of the dental slurry directly from a CAD digital model in 30 min. Inkjet color printing using stable Al2O3 and ZrO 2 aqueous suspensions has been developed to fabricate

  1. A novel method of freeform surface grinding with a soft wheel based on industrial robots

    Science.gov (United States)

    Sha, Sheng-chun; Guo, Xiao-ling

    2011-08-01

    In order to meet the growing demand for high-quality images, optical elements of freeform surface are more and more applied to imaging system. However the fabrication of freeform surface optical elements is much more difficult than that of traditional spherical ones. Recent research on freeform surface manufacture often deals with precision machine tools which have limitations on dimensions and are always expensive. Little has been researched on industrial robots. In this paper, a new method of freeform surface grinding based on industrial robots was found. This method could be applied to both whole surface grinding as well as partial surface grinding. The diameter of lenses to be ground would not be restricted to the machine tool's size. In this method a high-speed-rotating soft wheel was used. The relation between removing amount and grinding time which could be called removing function was established and measured. The machining precision was achieved by means of controlling the grinding time instead of the machine tool or industrial robot itself. There are two main factors affecting the removing function: i).rotating speed of the soft wheel; ii).pressure between the wheel and the work piece. In this paper, two groups of experiments have been conducted. One is the removing function tested at constant rotating speed while under different pressure. The other is that tested under a certain pressure with variable speed. Tables and curves which can show the effect of speed and pressure on the removing efficiency have been obtained. Cause for inaccuracy between experiment data and calculated result according to the theory and the non-linearity in the curves was analyzed. Through these analyses the removing function could be concluded under certain condition including rotating speed and pressure. Finally several experiments were performed to verify the appropriateness of the removing function. It could also be concluded that this method was more efficient in comparison

  2. Propulsion Design With Freeform Fabrication (PDFF)

    Science.gov (United States)

    Barnes, Daudi; McKinnon, James; Priem, Richard

    2010-01-01

    The nation is challenged to decrease the cost and schedule to develop new space transportation propulsion systems for commercial, scientific, and military purposes. Better design criteria and manufacturing techniques for small thrusters are needed to meet current applications in missile defense, space, and satellite propulsion. The requirements of these systems present size, performance, and environmental demands on these thrusters that have posed significant challenges to the current designers and manufacturers. Designers are limited by manufacturing processes, which are complex, costly, and time consuming, and ultimately limited in their capabilities. The PDFF innovation vastly extends the design opportunities of rocket engine components and systems by making use of the unique manufacturing freedom of solid freeform rapid prototype manufacturing technology combined with the benefits of ceramic materials. The unique features of PDFF are developing and implementing a design methodology that uses solid freeform fabrication (SFF) techniques to make propulsion components with significantly improved performance, thermal management, power density, and stability, while reducing development and production costs. PDFF extends the design process envelope beyond conventional constraints by leveraging the key feature of the SFF technique with the capability to form objects with nearly any geometric complexity without the need for elaborate machine setup. The marriage of SFF technology to propulsion components allows an evolution of design practice to harmonize material properties with functional design efficiency. Reduced density of materials when coupled with the capability to honeycomb structure used in the injector will have significant impact on overall mass reduction. Typical thrusters in use for attitude control have 60 90 percent of its mass in the valve and injector, which is typically made from titanium. The combination of material and structure envisioned for use in

  3. Efficient free-form surface representation with application in orthodontics

    Science.gov (United States)

    Yamany, Sameh M.; El-Bialy, Ahmed M.

    1999-03-01

    Orthodontics is the branch of dentistry concerned with the study of growth of the craniofacial complex. The detection and correction of malocclusion and other dental abnormalities is one of the most important and critical phases of orthodontic diagnosis. This paper introduces a system that can assist in automatic orthodontics diagnosis. The system can be used to classify skeletal and dental malocclusion from a limited number of measurements. This system is not intended to deal with several cases but is aimed at cases more likely to be encountered in epidemiological studies. Prior to the measurement of the orthodontics parameters, the position of the teeth in the jaw model must be detected. A new free-form surface representation is adopted for the efficient and accurate segmentation and separation of teeth from a scanned jaw model. THe new representation encodes the curvature and surface normal information into a 2D image. Image segmentation tools are then sued to extract structures of high/low curvature. By iteratively removing these structures, individual teeth surfaces are obtained.

  4. Fast free-form deformable registration via calculus of variations

    International Nuclear Information System (INIS)

    Lu Weiguo; Chen Mingli; Olivera, Gustavo H; Ruchala, Kenneth J; Mackie, Thomas R

    2004-01-01

    In this paper, we present a fully automatic, fast and accurate deformable registration technique. This technique deals with free-form deformation. It minimizes an energy functional that combines both similarity and smoothness measures. By using calculus of variations, the minimization problem was represented as a set of nonlinear elliptic partial differential equations (PDEs). A Gauss-Seidel finite difference scheme is used to iteratively solve the PDE. The registration is refined by a multi-resolution approach. The whole process is fully automatic. It takes less than 3 min to register two three-dimensional (3D) image sets of size 256 x 256 x 61 using a single 933 MHz personal computer. Extensive experiments are presented. These experiments include simulations, phantom studies and clinical image studies. Experimental results show that our model and algorithm are suited for registration of temporal images of a deformable body. The registration of inspiration and expiration phases of the lung images shows that the method is able to deal with large deformations. When applied to the daily CT images of a prostate patient, the results show that registration based on iterative refinement of displacement field is appropriate to describe the local deformations in the prostate and the rectum. Similarity measures improved significantly after the registration. The target application of this paper is for radiotherapy treatment planning and evaluation that incorporates internal organ deformation throughout the course of radiation therapy. The registration method could also be equally applied in diagnostic radiology

  5. High-efficiency free-form condenser overcoming rotational symmetry limitations.

    Science.gov (United States)

    Miñano, Juan C; Benítez, Pablo; Blen, José; Santamaría, Asunción

    2008-12-08

    Conventional condensers using rotational symmetric devices perform far from their theoretical limits when transferring optical power from sources such as arc lamps or halogen bulbs to the rectangular entrance of homogenizing prisms (target). We present a free-form condenser design (calculated with the SMS method) that overcomes the limitations inherent to rotational devices and can send to the target 1.8 times the power sent by an equivalent elliptical condenser for a 4:1 target aspect ratio and 1.5 times for 16:9 target and for practical values of target etendue.

  6. Advanced free-form micro tooling

    DEFF Research Database (Denmark)

    Tosello, Guido; Gavillet, J.

    2011-01-01

    -beam lithography and nano imprinting lithography [Che05][Che09] have high manufacturing cost and a low throughput. The aim was obtain large tool area with nano structures patterning without using energy intensive nano machining (e.g. focus ion beam, X-ray lithography, etc) but, instead, by exploiting the advantage......The present deliverable contains the report of the work and results achieved within the framework of WP 2.2 in Tasks 2.2.4 “Advanced free-form micro tooling” in experimental research done regarding practical applications of methods of applying nano structures to tooling solutions. As part of Task 2.......2.4, tests based on three different chemical-based-batch techniques to establish surface nano (i.e. sub-μm) structures on large tools area were performed. The three approached regarded: o Scheme 1  The use of Ø500nm nanobeads deposition for direct patterning of a Ø4inch. silicon wafer and subsequent nickel...

  7. Freeform object design and simultaneous manufacturing

    Science.gov (United States)

    Zhang, Wei; Zhang, Weihan; Lin, Heng; Leu, Ming C.

    2003-04-01

    Today's product design, especially the consuming product design, focuses more and more on individuation, originality, and the time to market. One way to meet these challenges is using the interactive and creationary product design methods and rapid prototyping/rapid tooling. This paper presents a novel Freeform Object Design and Simultaneous Manufacturing (FODSM) method that combines the natural interaction feature in the design phase and simultaneous manufacturing feature in the prototyping phase. The natural interactive three-dimensional design environment is achieved by adopting virtual reality technology. The geometry of the designed object is defined through the process of "virtual sculpting" during which the designer can touch and visualize the designed object and can hear the virtual manufacturing environment noise. During the designing process, the computer records the sculpting trajectories and automatically translates them into NC codes so as to simultaneously machine the designed part. The paper introduced the principle, implementation process, and key techniques of the new method, and compared it with other popular rapid prototyping methods.

  8. Measuring Modularity in Open Source Code Bases

    Directory of Open Access Journals (Sweden)

    Roberto Milev

    2009-03-01

    Full Text Available Modularity of an open source software code base has been associated with growth of the software development community, the incentives for voluntary code contribution, and a reduction in the number of users who take code without contributing back to the community. As a theoretical construct, modularity links OSS to other domains of research, including organization theory, the economics of industry structure, and new product development. However, measuring the modularity of an OSS design has proven difficult, especially for large and complex systems. In this article, we describe some preliminary results of recent research at Carleton University that examines the evolving modularity of large-scale software systems. We describe a measurement method and a new modularity metric for comparing code bases of different size, introduce an open source toolkit that implements this method and metric, and provide an analysis of the evolution of the Apache Tomcat application server as an illustrative example of the insights gained from this approach. Although these results are preliminary, they open the door to further cross-discipline research that quantitatively links the concerns of business managers, entrepreneurs, policy-makers, and open source software developers.

  9. Freeform Optics: current challenges for future serial production

    Science.gov (United States)

    Schindler, C.; Köhler, T.; Roth, E.

    2017-10-01

    One of the major developments in optics industry recently is the commercial manufacturing of freeform surfaces for optical mid- and high performance systems. The loss of limitation on rotational symmetry enables completely new optical design solutions - but causes completely new challenges for the manufacturer too. Adapting the serial production from radial-symmetric to freeform optics cannot be done just by the extension of machine capabilities and software for every process step. New solutions for conventional optics productions or completely new process chains are necessary.

  10. Optimization of freeform lightpipes for light-emitting-diode projectors.

    Science.gov (United States)

    Fournier, Florian; Rolland, Jannick

    2008-03-01

    Standard nonimaging components used to collect and integrate light in light-emitting-diode-based projector light engines such as tapered rods and compound parabolic concentrators are compared to optimized freeform shapes in terms of transmission efficiency and spatial uniformity. We show that the simultaneous optimization of the output surface and the profile shape yields transmission efficiency within the étendue limit up to 90% and spatial uniformity higher than 95%, even for compact sizes. The optimization process involves a manual study of the trends for different shapes and the use of an optimization algorithm to further improve the performance of the freeform lightpipe.

  11. A task specific uncertainty analysis method for least-squares-based form characterization of ultra-precision freeform surfaces

    International Nuclear Information System (INIS)

    Ren, M J; Cheung, C F; Kong, L B

    2012-01-01

    In the measurement of ultra-precision freeform surfaces, least-squares-based form characterization methods are widely used to evaluate the form error of the measured surfaces. Although many methodologies have been proposed in recent years to improve the efficiency of the characterization process, relatively little research has been conducted on the analysis of associated uncertainty in the characterization results which may result from those characterization methods being used. As a result, this paper presents a task specific uncertainty analysis method with application in the least-squares-based form characterization of ultra-precision freeform surfaces. That is, the associated uncertainty in the form characterization results is estimated when the measured data are extracted from a specific surface with specific sampling strategy. Three factors are considered in this study which include measurement error, surface form error and sample size. The task specific uncertainty analysis method has been evaluated through a series of experiments. The results show that the task specific uncertainty analysis method can effectively estimate the uncertainty of the form characterization results for a specific freeform surface measurement

  12. A method of LED free-form tilted lens rapid modeling based on scheme language

    Science.gov (United States)

    Dai, Yidan

    2017-10-01

    According to nonimaging optical principle and traditional LED free-form surface lens, a new kind of LED free-form tilted lens was designed. And a method of rapid modeling based on Scheme language was proposed. The mesh division method was applied to obtain the corresponding surface configuration according to the character of the light source and the desired energy distribution on the illumination plane. Then 3D modeling software and the Scheme language programming are used to generate lens model respectively. With the help of optical simulation software, a light source with the size of 1mm*1mm*1mm in volume is used in experiment, and the lateral migration distance of illumination area is 0.5m, in which total one million rays are computed. We could acquire the simulated results of both models. The simulated output result shows that the Scheme language can prevent the model deformation problems caused by the process of the model transfer, and the degree of illumination uniformity is reached to 82%, and the offset angle is 26°. Also, the efficiency of modeling process is greatly increased by using Scheme language.

  13. Fabrication of high precision metallic freeform mirrors with magnetorheological finishing (MRF)

    Science.gov (United States)

    Beier, Matthias; Scheiding, Sebastian; Gebhardt, Andreas; Loose, Roman; Risse, Stefan; Eberhardt, Ramona; Tünnermann, Andreas

    2013-09-01

    The fabrication of complex shaped metal mirrors for optical imaging is a classical application area of diamond machining techniques. Aspherical and freeform shaped optical components up to several 100 mm in diameter can be manufactured with high precision in an acceptable amount of time. However, applications are naturally limited to the infrared spectral region due to scatter losses for shorter wavelengths as a result of the remaining periodic diamond turning structure. Achieving diffraction limited performance in the visible spectrum demands for the application of additional polishing steps. Magnetorheological Finishing (MRF) is a powerful tool to improve figure and finish of complex shaped optics at the same time in a single processing step. The application of MRF as a figuring tool for precise metal mirrors is a nontrivial task since the technology was primarily developed for figuring and finishing a variety of other optical materials, such as glasses or glass ceramics. In the presented work, MRF is used as a figuring tool for diamond turned aluminum lightweight mirrors with electroless nickel plating. It is applied as a direct follow-up process after diamond machining of the mirrors. A high precision measurement setup, composed of an interferometer and an advanced Computer Generated Hologram with additional alignment features, allows for precise metrology of the freeform shaped optics in short measuring cycles. Shape deviations less than 150 nm PV / 20 nm rms are achieved reliably for freeform mirrors with apertures of more than 300 mm. Characterization of removable and induced spatial frequencies is carried out by investigating the Power Spectral Density.

  14. Sources and protective measures of indoor radon

    International Nuclear Information System (INIS)

    Gou Quanlu; Wang Hengde

    1993-01-01

    This paper presents the relative contribution to indoor radon 222 Rn of various sources in twenty three rooms of three kinds in Taiyuan area. The results show that the major sources in this area are radon emanation from surfaces of soil and building materials and that from outdoor air, while the contribution of water and gas consumed in the rooms is less important. These results suggest a basis for taking suitable protective measures against indoor radon. Some materials are also recommended which are effective in restraining radon exhalation and low in price, by testing more than ten kinds of materials and comparing them using cost-effectiveness analysis technique, such as painting materials, polyvinyl alcohol (CH 2 :CHOH)n, etc. Their sealing effects on radon exhalation were examined with home-made REM-89 Radon Exhalation Monitor. The deposition effects of negative ion generator and humidifier on radon progeny were also tested. The maximum deposition may reach 70-90%, which proves they are also effective and economical in radon protection. (2 tabs., 3 figs.)

  15. Aircrew radiation exposure: sources-risks-measurement

    International Nuclear Information System (INIS)

    Duftschmid, K.E.

    1994-05-01

    A short review is given on the actual aircrew exposure and its sources. The resulting risks for harmful effects to the health and discuss methods for in-flight measurements of exposure is evaluated. An idea for a fairly simple and economic approach to a practical, airborne active dosimeter for the assessment of individual crew exposure is presented. The exposure of civil aircrew to cosmic radiation, should not be considered a tremendous risk to the health, there is no reason for panic. However, being significantly higher than the average exposure to radiation workers, it can certainly not be neglected. As recommended by ICRP, aircrew exposure has to be considered occupational radiation exposure and aircrews are certainly entitled to the same degree of protection, as other ground-based radiation workers have obtained by law, since long time. (author)

  16. Structural optimization of free-form reciprocal structures

    DEFF Research Database (Denmark)

    Parigi, Dario

    2014-01-01

    This paper presents an optimization algorithm for the design of structurally efficient free-form reciprocal structures. Because of the geometric complexity of reciprocal structures, only a few structural studies have been carried out so far, and we have a limited knowledge of the relation between...

  17. Design of compact freeform lens for application specific Light-Emitting Diode packaging.

    Science.gov (United States)

    Wang, Kai; Chen, Fei; Liu, Zongyuan; Luo, Xiaobing; Liu, Sheng

    2010-01-18

    Application specific LED packaging (ASLP) is an emerging technology for high performance LED lighting. We introduced a practical design method of compact freeform lens for extended sources used in ASLP. A new ASLP for road lighting was successfully obtained by integrating a polycarbonate compact freeform lens of small form factor with traditional LED packaging. Optical performance of the ASLP was investigated by both numerical simulation based on Monte Carlo ray tracing method and experiments. Results demonstrated that, comparing with traditional LED module integrated with secondary optics, the ASLP had advantages of much smaller size in volume (approximately 1/8), higher system lumen efficiency (approximately 8.1%), lower cost and more convenience for customers to design and assembly, enabling possible much wider applications of LED for general road lighting. Tolerance analyses were also conducted. Installation errors of horizontal and vertical deviations had more effects on the shape and uniformity of radiation pattern compared with rotational deviation. The tolerances of horizontal, vertical and rotational deviations of this lens were 0.11 mm, 0.14 mm and 2.4 degrees respectively, which were acceptable in engineering.

  18. LED surgical lighting system with multiple free-form surfaces for highly sterile operating theater application.

    Science.gov (United States)

    Liu, Peng; Zhang, Yaqin; Zheng, Zhenrong; Li, Haifeng; Liu, Xu

    2014-06-01

    Although the ventilation system is widely employed in the operating theater, a strictly sterile surgical environment still cannot be ensured because of laminar disturbance, which is mainly caused by the surgical lighting system. Abandoning traditional products, we propose an LED surgical lighting system, which can alleviate the laminar disturbance and provide an appropriate lighting condition for surgery. It contains a certain amount of LED lens units, which are embedded in the ceiling and arranged around the air supply smallpox. The LED lens unit integrated with an LED light source and a free-form lens is required to produce a uniform circular illumination with a large tolerance to the change of lighting distance. To achieve such a dedicated lens, two free-form refractive surfaces, which are converted into two ordinary differential equations by the design method presented in this paper, are used to deflect the rays. The results show that the LED surgical lighting system can provide an excellent illumination environment for surgery, and, apparently, the laminar disturbance also can be relieved.

  19. Photogrammetric measurement of 3D freeform millimetre-sized objects with micro features: an experimental validation of the close-range camera calibration model for narrow angles of view

    Science.gov (United States)

    Percoco, Gianluca; Sánchez Salmerón, Antonio J.

    2015-09-01

    The measurement of millimetre and micro-scale features is performed by high-cost systems based on technologies with narrow working ranges to accurately control the position of the sensors. Photogrammetry would lower the costs of 3D inspection of micro-features and would be applicable to the inspection of non-removable micro parts of large objects too. Unfortunately, the behaviour of photogrammetry is not known when photogrammetry is applied to micro-features. In this paper, the authors address these issues towards the application of digital close-range photogrammetry (DCRP) to the micro-scale, taking into account that in literature there are research papers stating that an angle of view (AOV) around 10° is the lower limit to the application of the traditional pinhole close-range calibration model (CRCM), which is the basis of DCRP. At first a general calibration procedure is introduced, with the aid of an open-source software library, to calibrate narrow AOV cameras with the CRCM. Subsequently the procedure is validated using a reflex camera with a 60 mm macro lens, equipped with extension tubes (20 and 32 mm) achieving magnification of up to 2 times approximately, to verify literature findings with experimental photogrammetric 3D measurements of millimetre-sized objects with micro-features. The limitation experienced by the laser printing technology, used to produce the bi-dimensional pattern on common paper, has been overcome using an accurate pattern manufactured with a photolithographic process. The results of the experimental activity prove that the CRCM is valid for AOVs down to 3.4° and that DCRP results are comparable with the results of existing and more expensive commercial techniques.

  20. Photogrammetric measurement of 3D freeform millimetre-sized objects with micro features: an experimental validation of the close-range camera calibration model for narrow angles of view

    International Nuclear Information System (INIS)

    Percoco, Gianluca; Sánchez Salmerón, Antonio J

    2015-01-01

    The measurement of millimetre and micro-scale features is performed by high-cost systems based on technologies with narrow working ranges to accurately control the position of the sensors. Photogrammetry would lower the costs of 3D inspection of micro-features and would be applicable to the inspection of non-removable micro parts of large objects too. Unfortunately, the behaviour of photogrammetry is not known when photogrammetry is applied to micro-features.In this paper, the authors address these issues towards the application of digital close-range photogrammetry (DCRP) to the micro-scale, taking into account that in literature there are research papers stating that an angle of view (AOV) around 10° is the lower limit to the application of the traditional pinhole close-range calibration model (CRCM), which is the basis of DCRP.At first a general calibration procedure is introduced, with the aid of an open-source software library, to calibrate narrow AOV cameras with the CRCM. Subsequently the procedure is validated using a reflex camera with a 60 mm macro lens, equipped with extension tubes (20 and 32 mm) achieving magnification of up to 2 times approximately, to verify literature findings with experimental photogrammetric 3D measurements of millimetre-sized objects with micro-features. The limitation experienced by the laser printing technology, used to produce the bi-dimensional pattern on common paper, has been overcome using an accurate pattern manufactured with a photolithographic process.The results of the experimental activity prove that the CRCM is valid for AOVs down to 3.4° and that DCRP results are comparable with the results of existing and more expensive commercial techniques. (paper)

  1. Mobile source air toxics mitigation measures.

    Science.gov (United States)

    2013-10-01

    In accordance with the Federal Highway Administration (FHWA) Interim Guidance Update on Mobile Source Air Toxic Analysis in NEPA Documents (September 30, 2009), transportation projects subject to the National Environmental Policy Act (NEPA) mus...

  2. Digitally switchable multi-focal lens using freeform optics.

    Science.gov (United States)

    Wang, Xuan; Qin, Yi; Hua, Hong; Lee, Yun-Han; Wu, Shin-Tson

    2018-04-16

    Optical technologies offering electrically tunable optical power have found a broad range of applications, from head-mounted displays for virtual and augmented reality applications to microscopy. In this paper, we present a novel design and prototype of a digitally switchable multi-focal lens (MFL) that offers the capability of rapidly switching the optical power of the system among multiple foci. It consists of a freeform singlet and a customized programmable optical shutter array (POSA). Time-multiplexed multiple foci can be obtained by electrically controlling the POSA to switch the light path through different segments of the freeform singlet rapidly. While this method can be applied to a broad range of imaging and display systems, we experimentally demonstrate a proof-of-concept prototype for a multi-foci imaging system.

  3. Towards freeform curved blazed gratings using diamond machining

    Science.gov (United States)

    Bourgenot, C.; Robertson, D. J.; Stelter, D.; Eikenberry, S.

    2016-07-01

    Concave blazed gratings greatly simplify the architecture of spectrographs by reducing the number of optical components. The production of these gratings using diamond-machining offers practically no limits in the design of the grating substrate shape, with the possibility of making large sag freeform surfaces unlike the alternative and traditional method of holography and ion etching. In this paper, we report on the technological challenges and progress in the making of these curved blazed gratings using an ultra-high precision 5 axes Moore-Nanotech machine. We describe their implementation in an integral field unit prototype called IGIS (Integrated Grating Imaging Spectrograph) where freeform curved gratings are used as pupil mirrors. The goal is to develop the technologies for the production of the next generation of low-cost, compact, high performance integral field unit spectrometers.

  4. Electron beam freeforming of stainless steel using solid wire feed

    International Nuclear Information System (INIS)

    Wanjara, P.; Brochu, M.; Jahazi, M.

    2007-01-01

    The use of electron beam technology for freeforming build-ups on 321 stainless steel substrates was investigated in this work by using 347 stainless steel as a filler metal. The electron beam freeforming studies indicated that line build-ups could be deposited on the substrate material for optimized processing conditions and a slight linear thickening of the re-build occurred as a function of the deposited layer. The evolution in the formation of the Ti (C, N) (Nb, Ti) carbonitrides and Nb (C, N) precipitates was demonstrated to counteract the formation of detrimental Cr-carbides usually observed during welding stainless steels. The mechanical properties of the re-build were similar to the properties of the base metal, showing that homogeneous properties can be expected in the repaired components

  5. Source preparations for alpha and beta measurements

    Energy Technology Data Exchange (ETDEWEB)

    Holm, E. [Risoe National Lab., Roskilde (Denmark)

    2001-01-01

    Regarding alpha particle emitters subject for environmental studies, electrodeposition or co-precipitation as fluorides are the most common methods. For electro deposition stainless steel is generally used as cathode material but also other metals such as Ni, Ag, and Cu showed promising results. The use of other anode material than platinum, such as graphite should be investigated. For other purposes such as optimal resolution other more sophisticated methods are used but often resulting in poorer recovery. For beta particle emitters the type of detection system will decide the source preparation. Similar methods as for alpha particle emitters, electrodeposition or precipitation techniques can be used. Due to the continuous energy distribution of the beta pulse height distribution a high resolution is not required. Thicker sources from the precipitates or a stable isotopic carrier can be accepted but correction for absorption in the source must be done. (au)

  6. Experimental characterization of variable output refractive beamshapers using freeform elements

    Science.gov (United States)

    Shultz, Jason A.; Smilie, Paul J.; Dutterer, Brian S.; Davies, Matthew A.; Suleski, Thomas J.

    2014-09-01

    We present experimental results from variable output refractive beam shapers based on freeform optical surfaces. Two freeform elements in close proximity comprise a beam shaper that maps a circular Gaussian input to a circular `flat-top' output. Different lateral relative shifts between the elements result in a varying output diameter while maintaining the uniform irradiance distribution. We fabricated the beam shaping elements in PMMA using multi-axis milling on a Moore Nanotech 350FG diamond machining center and tested with a 632.8 nm Gaussian input. Initial optical testing confirmed both the predicted beam shaping and variable functionality, but with poor output uniformity. The effects of surface finish on optical performance were investigated using LightTrans VirtualLabTM to perform physical optics simulations of the milled freeform surfaces. These simulations provided an optimization path for determining machining parameters to improve the output uniformity of the beam shaping elements. A second variable beam shaper based on a super-Gaussian output was designed and fabricated using the newly determined machining parameters. Experimental test results from the second beam shaper showed outputs with significantly higher quality, but also suggest additional areas of study for further improvements in uniformity.

  7. APPROXIMATION OF FREE-FORM CURVE – AIRFOIL SHAPE

    Directory of Open Access Journals (Sweden)

    CHONG PERK LIN

    2013-12-01

    Full Text Available Approximation of free-form shape is essential in numerous engineering applications, particularly in automotive and aircraft industries. Commercial CAD software for the approximation of free-form shape is based almost exclusively on parametric polynomial and rational parametric polynomial. The parametric curve is defined by vector function of one independent variable R(u = (x(u, y(u, z(u, where 0≤u≤1. Bézier representation is one of the parametric functions, which is widely used in the approximating of free-form shape. Given a string of points with the assumption of sufficiently dense to characterise airfoil shape, it is desirable to approximate the shape with Bézier representation. The expectation is that the representation function is close to the shape within an acceptable working tolerance. In this paper, the aim is to explore the use of manual and automated methods for approximating section curve of airfoil with Bézier representation.

  8. Theory of aberration fields for general optical systems with freeform surfaces.

    Science.gov (United States)

    Fuerschbach, Kyle; Rolland, Jannick P; Thompson, Kevin P

    2014-11-03

    This paper utilizes the framework of nodal aberration theory to describe the aberration field behavior that emerges in optical systems with freeform optical surfaces, particularly φ-polynomial surfaces, including Zernike polynomial surfaces, that lie anywhere in the optical system. If the freeform surface is located at the stop or pupil, the net aberration contribution of the freeform surface is field constant. As the freeform optical surface is displaced longitudinally away from the stop or pupil of the optical system, the net aberration contribution becomes field dependent. It is demonstrated that there are no new aberration types when describing the aberration fields that arise with the introduction of freeform optical surfaces. Significantly it is shown that the aberration fields that emerge with the inclusion of freeform surfaces in an optical system are exactly those that have been described by nodal aberration theory for tilted and decentered optical systems. The key contribution here lies in establishing the field dependence and nodal behavior of each freeform term that is essential knowledge for effective application to optical system design. With this development, the nodes that are distributed throughout the field of view for each aberration type can be anticipated and targeted during optimization for the correction or control of the aberrations in an optical system with freeform surfaces. This work does not place any symmetry constraints on the optical system, which could be packaged in a fully three dimensional geometry, without fold mirrors.

  9. Machining and metrology systems for free-form laser printer mirrors

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    optical systems were designed and manufactured for the individual laser wavelength to be ... The design objective in utilizing a free-form mirror has resulted in a corresponding ... Since mass production of these free-form mirrors is required, the ...

  10. Aberration analysis for freeform surface terms overlay on general decentered and tilted optical surfaces.

    Science.gov (United States)

    Yang, Tong; Cheng, Dewen; Wang, Yongtian

    2018-03-19

    Aberration theory helps designers to better understand the nature of imaging systems. However, the existing aberration theory of freeform surfaces has many limitations. For example, it only works in the special case when the central area of the freeform surface is used. In addition, the light footprint is limited to a circle, which does not match the case of an elliptical footprint for general systems. In this paper, aberrations generated by freeform surface term overlay on general decentered and tilted optical surfaces are analyzed. For the case when the off-axis section of a freeform surface is used, the aberration equation for using stop and nonstop surfaces is discussed, and the aberrations generated by Zernike terms up to Z 17/18 are analyzed in detail. To solve the problem of the elliptical light footprint for tilted freeform surfaces, the scaled pupil vector is used in the aberration analysis. The mechanism of aberration transformation is discovered, and the aberrations generated by different Zernike terms in this case are calculated. Finally we proposed aberration equations for freeform terms on general decentered and tilted freeform surfaces. The research result given in this paper offers an important reference for optical designers and engineers, and it is of great importance in developing analytical methods for general freeform system design, tolerance analysis, and system assembly.

  11. Source term measurements on vitrified HLW

    International Nuclear Information System (INIS)

    Hough, A.; Marples, J.A.C.

    1988-01-01

    The equilibrium concentrations of Tc-99, Np-237, Pu-239/240 and Am-241 have been measured in the presence of materials likely to be present in a vitrified HLW repository: glass, iron, backfill and rock. Results were measured under both oxidising and reducing conditions and at pH values set by the backfill bentonite and cement. Under reducing conditions and with cementitious backfills, the equilibrium concentrations ranged from three to 30 times allowed drinking water levels for the four isotopes. (author)

  12. Microflown based monopole sound sources for reciprocal measurements

    NARCIS (Netherlands)

    Bree, H.E. de; Basten, T.G.H.

    2008-01-01

    Monopole sound sources (i.e. omni directional sound sources with a known volume velocity) are essential for reciprocal measurements used in vehicle interior panel noise contribution analysis. Until recently, these monopole sound sources use a sound pressure transducer sensor as a reference sensor. A

  13. Evaluation of Sources of Uncertainties in Solar Resource Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sengupta, Manajit [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-25

    This poster presents a high-level overview of sources of uncertainties in solar resource measurement, demonstrating the impact of various sources of uncertainties -- such as cosine response, thermal offset, spectral response, and others -- on the accuracy of data from several radiometers. The study provides insight on how to reduce the impact of some of the sources of uncertainties.

  14. The magnet measurement facility for the Advanced Photon Source

    International Nuclear Information System (INIS)

    Kim, S.H.; Doose, C.; Hogrefe, R.; Kim, K.; Merl, R.

    1993-01-01

    A magnet measurement facility has been developed to measure the prototype and production magnets for the Advance Photon Source. The measurement facility is semi-automatic in measurement control and data analysis. One dipole system and three rotating coil measurement systems for quadrupole and sextupole magnets and corresponding probe coils are described

  15. Procedures for measurement of anisotropy factor of neutron sources

    International Nuclear Information System (INIS)

    Creazolla, P.G.; Camargo, A.; Astuto, A.; Silva, F.; Pereira, W.W.

    2017-01-01

    Radioisotope sources of neutrons allow the production of reference fields for calibration of neutron measurement devices for radioprotection and analysis purposes. When the emission rate of these sources is isotropic, no correction is necessary. However, variations in the source capsule material and variations in the concentration of the emitting material may produce differences in its neutron emission rate relative to the source axis, this effect is called anisotropy. A proposed procedure for measuring the anisotropy factor of the sources belonging to the IRD/LNMRI/LN Neutron Metrology Laboratory using a Precision Long Counter (PLC) detector will be presented

  16. The OpenPMU Platform for Open Source Phasor Measurements

    OpenAIRE

    Laverty, David M.; Best, Robert J.; Brogan, Paul; Al-Khatib, Iyad; Vanfretti, Luigi; Morrow, D John

    2013-01-01

    OpenPMU is an open platform for the development of phasor measurement unit (PMU) technology. A need has been identified for an open-source alternative to commercial PMU devices tailored to the needs of the university researcher and for enabling the development of new synchrophasor instruments from this foundation. OpenPMU achieves this through open-source hardware design specifications and software source code, allowing duplicates of the OpenPMU to be fabricated under open-source licenses. Th...

  17. Data format standard for sharing light source measurements

    Science.gov (United States)

    Gregory, G. Groot; Ashdown, Ian; Brandenburg, Willi; Chabaud, Dominique; Dross, Oliver; Gangadhara, Sanjay; Garcia, Kevin; Gauvin, Michael; Hansen, Dirk; Haraguchi, Kei; Hasna, Günther; Jiao, Jianzhong; Kelley, Ryan; Koshel, John; Muschaweck, Julius

    2013-09-01

    Optical design requires accurate characterization of light sources for computer aided design (CAD) software. Various methods have been used to model sources, from accurate physical models to measurement of light output. It has become common practice for designers to include measured source data for design simulations. Typically, a measured source will contain rays which sample the output distribution of the source. The ray data must then be exported to various formats suitable for import into optical analysis or design software. Source manufacturers are also making measurements of their products and supplying CAD models along with ray data sets for designers. The increasing availability of data has been beneficial to the design community but has caused a large expansion in storage needs for the source manufacturers since each software program uses a unique format to describe the source distribution. In 2012, the Illuminating Engineering Society (IES) formed a working group to understand the data requirements for ray data and recommend a standard file format. The working group included representatives from software companies supplying the analysis and design tools, source measurement companies providing metrology, source manufacturers creating the data and users from the design community. Within one year the working group proposed a file format which was recently approved by the IES for publication as TM-25. This paper will discuss the process used to define the proposed format, highlight some of the significant decisions leading to the format and list the data to be included in the first version of the standard.

  18. A Sketching Interface for Freeform 3D Modeling

    Science.gov (United States)

    Igarashi, Takeo

    This chapter introduces Teddy, a sketch-based modeling system to quickly and easily design freeform models such as stuffed animals and other rotund objects. The user draws several 2D freeform strokes interactively on the screen and the system automatically constructs plausible 3D polygonal surfaces. Our system supports several modeling operations, including the operation to construct a 3D polygonal surface from a 2D silhouette drawn by the user: it inflates the region surrounded by the silhouette making a wide area fat, and a narrow area thin. Teddy, our prototype system, is implemented as a Java program, and the mesh construction is done in real-time on a standard PC. Our informal user study showed that a first-time user masters the operations within 10 minutes, and can construct interesting 3D models within minutes. We also report the result of a case study where a high school teacher taught various 3D concepts in geography using the system.

  19. RAPID FREEFORM SHEET METAL FORMING: TECHNOLOGY DEVELOPMENT AND SYSTEM VERIFICATION

    Energy Technology Data Exchange (ETDEWEB)

    Kiridena, Vijitha [Ford Scientific Research Lab., Dearborn, MI (United States); Verma, Ravi [Boeing Research and Technology (BR& T), Seattle, WA (United States); Gutowski, Timothy [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Roth, John [Pennsylvania State Univ., University Park, PA (United States)

    2018-03-31

    The objective of this project is to develop a transformational RApid Freeform sheet metal Forming Technology (RAFFT) in an industrial environment, which has the potential to increase manufacturing energy efficiency up to ten times, at a fraction of the cost of conventional technologies. The RAFFT technology is a flexible and energy-efficient process that eliminates the need for having geometry-specific forming dies. The innovation lies in the idea of using the energy resource at the local deformation area which provides greater formability, process control, and process flexibility relative to traditional methods. Double-Sided Incremental Forming (DSIF), the core technology in RAFFT, is a new concept for sheet metal forming. A blank sheet is clamped around its periphery and gradually deformed into a complex 3D freeform part by two strategically aligned stylus-type tools that follow a pre-described toolpath. The two tools, one on each side of the blank, can form a part with sharp features for both concave and convex shapes. Since deformation happens locally, the forming force at any instant is significantly decreased when compared to traditional methods. The key advantages of DSIF are its high process flexibility, high energy-efficiency, low capital investment, and the elimination of the need for massive amounts of die casting and machining. Additionally, the enhanced formability and process flexibility of DSIF can open up design spaces and result in greater weight savings.

  20. Freeform inkjet printing of cellular structures with bifurcations.

    Science.gov (United States)

    Christensen, Kyle; Xu, Changxue; Chai, Wenxuan; Zhang, Zhengyi; Fu, Jianzhong; Huang, Yong

    2015-05-01

    Organ printing offers a great potential for the freeform layer-by-layer fabrication of three-dimensional (3D) living organs using cellular spheroids or bioinks as building blocks. Vascularization is often identified as a main technological barrier for building 3D organs. As such, the fabrication of 3D biological vascular trees is of great importance for the overall feasibility of the envisioned organ printing approach. In this study, vascular-like cellular structures are fabricated using a liquid support-based inkjet printing approach, which utilizes a calcium chloride solution as both a cross-linking agent and support material. This solution enables the freeform printing of spanning and overhang features by providing a buoyant force. A heuristic approach is implemented to compensate for the axially-varying deformation of horizontal tubular structures to achieve a uniform diameter along their axial directions. Vascular-like structures with both horizontal and vertical bifurcations have been successfully printed from sodium alginate only as well as mouse fibroblast-based alginate bioinks. The post-printing fibroblast cell viability of printed cellular tubes was found to be above 90% even after a 24 h incubation, considering the control effect. © 2014 Wiley Periodicals, Inc.

  1. Friction Freeform Fabrication of Superalloy Inconel 718: Prospects and Problems

    Science.gov (United States)

    Dilip, J. J. S.; Janaki Ram, G. D.

    2014-01-01

    Friction Freeform Fabrication is a new solid-state additive manufacturing process. The present investigation reports a detailed study on the prospects of this process for additive part fabrication in superalloy Inconel 718. Using a rotary friction welding machine and employing alloy 718 consumable rods in solution treated condition, cylindrical-shaped multi-layer friction deposits (10 mm diameter) were successfully produced. In the as-deposited condition, the deposits showed very fine grain size with no grain boundary δ phase. The deposits responded well to direct aging and showed satisfactory room-temperature tensile properties. However, their stress rupture performance was unsatisfactory because of their layered microstructure with very fine grain size and no grain boundary δ phase. The problem was overcome by heat treating the deposits first at 1353 K (1080 °C) (for increasing the grain size) and then at 1223 K (950 °C) (for precipitating the δ phase). Overall, the current study shows that Friction Freeform Fabrication is a very useful process for additive part fabrication in alloy 718.

  2. Measuring Conflict in a Multi-Source Environment as a Normal Measure

    OpenAIRE

    Wei, Pan; Ball, John E.; Anderson, Derek T.; Harsh, Archit; Archibald, Christopher

    2018-01-01

    In a multi-source environment, each source has its own credibility. If there is no external knowledge about credibility then we can use the information provided by the sources to assess their credibility. In this paper, we propose a way to measure conflict in a multi-source environment as a normal measure. We examine our algorithm using three simulated examples of increasing conflict and one experimental example. The results demonstrate that the proposed measure can represent conflict in a me...

  3. Application research of tune measurement system in Hefei light source

    International Nuclear Information System (INIS)

    Sun Baogen; He Duohui; Xu Hongliang; Lu Ping; Wang Junhua; Gao Yunfeng; Wang Lin; Liu Jinying

    2002-01-01

    The author introduces the measurement and research of some beam parameters using tune measurement system for Hefei Light Source (HLS), which include the betatron tune, beta function, natural chromaticity, corrected chromaticity, and central frequency. Additionally, it also describes the measurement of the influence of DC clearing electrodes on the betatron tune shift and gives some measurement results. The measurement results are compared with the theoretical values and they are in good agreement

  4. Freeform étendue-preserving optics for light and color mixing

    Science.gov (United States)

    Sorgato, Simone; Mohedano, Rubén.; Chaves, Julio; Cvetkovic, Aleksandra; Hernández, Maikel; Benítez, Pablo; Miñano, Juan C.; Thienpont, Hugo; Duerr, Fabian

    2015-09-01

    Today's SSL illumination market shows a clear trend towards high flux packages with higher efficiency and higher CRI, realized by means of multiple color chips and phosphors. Such light sources require the optics to provide both near- and far-field color mixing. This design problem is particularly challenging for collimated luminaries, since traditional diffusers cannot be employed without enlarging the exit aperture and reducing brightness (so increasing étendue). Furthermore, diffusers compromise the light output ratio (efficiency) of the lamps to which they are applied. A solution, based on Köhler integration, consisting of a spherical cap comprising spherical microlenses on both its interior and exterior sides was presented in 2012. When placed on top of an inhomogeneous multichip Lambertian LED, this so-called Shell-Mixer creates a homogeneous (both spatially and angularly) virtual source, also Lambertian, where the images of the chips merge. The virtual source is located at the same position with essentially the same size of the original source. The diameter of this optics was 3 times that of the chip-array footprint. In this work, we present a new version of the Shell-Mixer, based on the Edge Ray Principle, where neither the overall shape of the cap nor the surfaces of the lenses are constrained to spheres or rotational Cartesian ovals. This new Shell- Mixer is freeform, only twice as large as the original chip-array and equals the original model in terms of brightness, color uniformity and efficiency.

  5. Integrating optical, mechanical, and test software (with applications to freeform optics)

    Science.gov (United States)

    Genberg, Victor; Michels, Gregory; Myer, Brian

    2017-10-01

    Optical systems must perform under environmental conditions including thermal and mechanical loading. To predict the performance in the field, integrated analysis combining optical and mechanical software is required. Freeform and conformal optics offer many new opportunities for optical design. The unconventional geometries can lead to unconventional, and therefore unintuitive, mechanical behavior. Finite element (FE) analysis offers the ability to predict the deformations of freeform optics under various environments and load conditions. To understand the impact on optical performance, the deformations must be brought into optical analysis codes. This paper discusses several issues related to the integrated optomechanical analysis of freeform optics.

  6. Procedure for measurement of anisotropy factor for neutron sources

    International Nuclear Information System (INIS)

    Creazolla, Prycylla Gomes

    2017-01-01

    Radioisotope neutron sources allow the production of reference fields for calibration of neutron detectors for radiation protection and analysis purposes. When the emission rate of these sources is isotropic, no correction is necessary. However, variations in source encapsulation and in the radioactive material concentration produce differences in its neutron emission rate, relative to the source axis, this effect is called anisotropy. In this study, is describe a procedure for measuring the anisotropy factor of neutron sources performed in the Laboratório de Metrologia de Neutrons (LN) using a Precision Long Counter (PLC) detector. A measurement procedure that takes into account the anisotropy factor of neutron sources contributes to solve some issues, particularly with respect to the high uncertainties associated with neutron dosimetry. Thus, a bibliographical review was carried out based on international standards and technical regulations specific to the area of neutron fields, and were later reproduced in practice by means of the procedure for measuring the anisotropy factor in neutron sources of the LN. The anisotropy factor is determined as a function of the angle of 90° in relation to the cylindrical axis of the source. This angle is more important due to its high use in measurements and also of its higher neutron emission rate if compared with other angles. (author)

  7. Laser driven white light source for BRDF measurement

    DEFF Research Database (Denmark)

    Amdemeskel, Mekbib Wubishet; Thorseth, Anders; Dam-Hansen, Carsten

    2017-01-01

    In this paper, we will present a setup with laser driven light source (LDLS) for measuring a 2D bidirectional reflectance distribution function (BRDF). We have carried out measurements to acquire the BRDF of different samples based on our setup: which consists of a new laser driven broadband light...... source (UV-VIS-NIR), spectroradiometer and sample holder stepper motor in a dark UV-protected environment. Here, we introduced a special kind of light source which has a bright, stable, broad spectral range and well collimated light output to give a very good angular resolution. The experimental results...

  8. Residual stress measurement using the pulsed neutron source at LANSCE

    International Nuclear Information System (INIS)

    Bourke, M.A.M.; Goldstone, J.A.; Holden, T.M.

    1991-01-01

    The presence of residual stress in engineering components can effect their mechanical properties and structural integrity. Neutron diffraction is the only measuring technique which can make spatially resolved non-destructive strain measurements in the interior of components. By recording the change in the crystalline interplanar spacing, elastic strains can be measured for individual lattice reflections. Using a pulsed neutron source, all the lattice reflections are recorded in each measurement which allows anisotropic effects to be studied. Measurements made at the Manuel Lujan Jr Neutron Scattering Centre (LANSCE) demonstrate the potential for stress measurements on a pulsed source and indicate the advantages and disadvantages over measurements made on a reactor. 15 refs., 7 figs

  9. SSL Freeform Generator v1.00

    Science.gov (United States)

    Kuchnik, Michael

    2014-01-01

    The Orion spacecraft utilizes a system of Compact Unique Identifiers (CUIs) to identify telemetry measurements in the process of communicating with the ground. While avionic systems are still in development, simulation of telemetric data must be used for the development of dependent systems. The SuperScript Language (SSL) developed by Honeywell Aerospace provides users a programming language for simulation of this data. The use of tools that provide SSL generation capabilities at a higher level allows for faster and more efficient generation of simulation waveforms. Previous SSL Generator implementations such as Orion Scripted Interface Generator (OrionSIG) relied on software supported routines to generate simulation points for the SSL scripts. This provided relevant simulation capabilities, but was reduced in flexibility by the available software routines available. For this approach, software supported routines have been entirely dropped. Rather, the user is required to enter their own simulation waveform input. This allows arbitrarily complex functions to be utilized simulated with maximum degree of freedom for the user.: The idea for this version of the SSL Generator was a mapping of arbitrary waveforms to Orion CUI telemetry data. The SSL Generator implemented offers a higher degree of freedom to the user than previous versions while attempting to maintain abstraction from the underlying SSL script and the Orion CUI data types. As such, many mappings of waveforms to CUIs will simply not work. Certain implementation decisions were made to minimize the damage caused by these unintended side-effects, such as saturation of values exceeding the maximum or minimum bounds of the data type. Other details, such as signed values being represented in unsigned data types, present problems which cant be fixed to an acceptable degree of intended behavior without user input. Awareness of the limitations of all layers of the software stack will increase the productivity of

  10. The Purdue Mechanics Freeform Classroom: A New Approach to Engineering Mechanics Education

    OpenAIRE

    Rhoads, Jeffrey F.; Nauman, Eric; Holloway, Beth M; Krousgrill, Charles Morton

    2014-01-01

    The [REMOVED] Mechanics Freeform Classroom: A New Approach to Engineering Mechanics EducationMotivated by the need to address the broad spectrum of learning styles embraced by today’sengineering students, a desire to encourage active, peer-to-peer, and self-learning, and a goal ofinteracting with every student despite ever-expanding enrollments, the mechanics faculty at[REMOVED] University have developed the [REMOVED] Mechanics Freeform Classroom(PMFC) -- a new approach to engineering mechani...

  11. User-Generated Free-Form Gestures for Authentication: Security and Memorability

    OpenAIRE

    Sherman, Michael; Clark, Gradeigh; Yang, Yulong; Sugrim, Shridatt; Modig, Arttu; Lindqvist, Janne; Oulasvirta, Antti; Roos, Teemu

    2014-01-01

    This paper studies the security and memorability of free-form multitouch gestures for mobile authentication. Towards this end, we collected a dataset with a generate-test-retest paradigm where participants (N=63) generated free-form gestures, repeated them, and were later retested for memory. Half of the participants decided to generate one-finger gestures, and the other half generated multi-finger gestures. Although there has been recent work on template-based gestures, there are yet no metr...

  12. Evaluation of Parameters Affecting Magnetic Abrasive Finishing on Concave Freeform Surface of Al Alloy via RSM Method

    Directory of Open Access Journals (Sweden)

    Mehrdad Vahdati

    2016-01-01

    Full Text Available The attempts of researchers in industries to obtain accurate and high quality surfaces led to the invention of new methods of finishing. Magnetic abrasive finishing (MAF is a relatively new type of finishing in which the magnetic field is used to control the abrasive tools. Applications such as the surface of molds are ones of the parts which require very high surface smoothness. Usually this type of parts has freeform surface. In this study, the effect of magnetic abrasive process parameters on freeform surfaces of parts made of aluminum is examined. This method is obtained through combination of magnetic abrasive process and Control Numerical Computer (CNC. The use of simple hemisphere for installation on the flat area of the magnets as well as magnets’ spark in curve form is a measure done during testing the experiments. The design of experiments is based on response surface methodology. The gap, the rotational speed of the spindle, and the feed rate are found influential and regression equations governing the process are also determined. The impact of intensity of the magnetic field is obtained using the finite element software of Maxwell. Results show that in concave areas of the surface, generally speaking, the surface roughness decreases to 0.2 μm from its initial 1.3 μm roughness. However, in some points the lowest surface roughness of 0.08 μm was measured.

  13. Freeform Compliant CMOS Electronic Systems for Internet of Everything Applications

    KAUST Repository

    Shaikh, Sohail F.

    2017-01-17

    The state-of-the-art electronics technology has been an integral part of modern advances. The prevalent rise of the mobile device and computational technology in the age of information technology offers exciting applications that are attributed to sophisticated, enormously reliable, and most mature CMOS-based electronics. We are accustomed to high performance, cost-effective, multifunctional, and energy-efficient scaled electronics. However, they are rigid, bulky, and brittle. The convolution of flexibility and stretchability in electronics for emerging Internet of Everything application can unleash smart application horizon in unexplored areas, such as robotics, healthcare, smart cities, transport, and entertainment systems. While flexible and stretchable device themes are being remarkably chased, the realization of the fully compliant electronic system is unaddressed. Integration of data processing, storage, communication, and energy management devices complements a compliant system. Here, a comprehensive review is presented on necessity and design criteria for freeform (physically flexible and stretchable) compliant high-performance CMOS electronic systems.

  14. Novel freeform optical surface design with spiral symmetry

    Science.gov (United States)

    Zamora, Pablo; Benítez, Pablo; Miñano, Juan C.; Vilaplana, Juan

    2011-10-01

    Manufacturing technologies as injection molding or embossing specify their production limits for minimum radii of the vertices or draft angle for demolding, for instance. These restrictions may limit the system optical efficiency or affect the generation of undesired artifacts on the illumination pattern when dealing with optical design. A novel manufacturing concept is presented here, in which the optical surfaces are not obtained from the usual revolution symmetry with respect to a central axis (z axis), but they are calculated as free-form surfaces describing a spiral trajectory around z axis. The main advantage of this new concept lies in the manufacturing process: a molded piece can be easily separated from its mold just by applying a combination of rotational movement around axis z and linear movement along axis z, even for negative draft angles. The general designing procedure will be described in detail.

  15. IR-laser assisted additive freeform optics manufacturing.

    Science.gov (United States)

    Hong, Zhihan; Liang, Rongguang

    2017-08-02

    Computer-controlled additive manufacturing (AM) processes, also known as three-dimensional (3D) printing, create 3D objects by the successive adding of a material or materials. While there have been tremendous developments in AM, the 3D printing of optics is lagging due to the limits in materials and tight requirements for optical applicaitons. We propose a new precision additive freeform optics manufacturing (AFOM) method using an pulsed infrared (IR) laser. Compared to ultraviolet (UV) curable materials, thermally curable optical silicones have a number of advantages, such as strong UV stability, non-yellowing, and high transmission, making it particularly suitable for optical applications. Pulsed IR laser radiation offers a distinct advantage in processing optical silicones, as the high peak intensity achieved in the focal region allows for curing the material quickly, while the brief duration of the laser-material interaction creates a negligible heat-affected zone.

  16. Multi-Scalar Modelling for Free-form Timber Structures

    DEFF Research Database (Denmark)

    Poinet, Paul; Nicholas, Paul; Tamke, Martin

    2016-01-01

    .The research explores the design probe of free-form structures composed of glue-laminated timber beams and looks at the different types of data that need to be shared among each discipline and across multiple scales from which different levels of resolution can be defined. A particular focus lies...... in the segmentation strategy of glue-laminated timber structures that depend on structural requirements and the different types of constraints related to fabrication, transportation and assembly. Where current working practices decouple segmentation processes within a discrete digital workflow, this research aims...... and techniques as a means to work within a continuous design environment in which an abstract network of timber beams is iteratively updated through geometrical and structural optimizations at different levels of resolution....

  17. Low noise constant current source for bias dependent noise measurements

    International Nuclear Information System (INIS)

    Talukdar, D.; Bose, Suvendu; Bardhan, K. K.; Chakraborty, R. K.

    2011-01-01

    A low noise constant current source used for measuring the 1/f noise in disordered systems in ohmic as well as nonohmic regime is described. The source can supply low noise constant current starting from as low as 1 μA to a few tens of milliampere with a high voltage compliance limit of around 20 V. The constant current source has several stages, which can work in a standalone manner or together to supply the desired value of load current. The noise contributed by the current source is very low in the entire current range. The fabrication of a low noise voltage preamplifier modified for bias dependent noise measurements and based on the existing design available in the MAT04 data sheet is also described.

  18. Preparation of protactinium measurement source by electroplating method

    International Nuclear Information System (INIS)

    Li Zongwei; Yang Weifan; Fang Keming; Yuan Shuanggui; Guo Junsheng; Pan Qiangyan

    1998-01-01

    An electroplating method for the preparation of Pa sources is described, and the main factors (such as pH value of solution, electroplating time and current density) influencing the electroplating of Pa are tested and discussed with 233 Pa as a tracer. A thin and uniform electroplating Pa-Layer of 1 mg/cm 2 thick on thin stainless steel disk was obtained. The Pa source was measured by a HPGe detector to determine the chemical efficiency

  19. Ion implanted Na22 source for positron lifetime measurements

    International Nuclear Information System (INIS)

    Fluss, M.J.; Smedeskjaer, L.C.

    1979-04-01

    A new positron source-sample fabrication technique, intended for high temperature positron annihilation measurements, was developed. The method makes use of a mass separator to implant pure Na 22 into the sample surface. The application of this technique to Cu is described. A brief discussion of the origin of the source component is given, and different possibilities of correcting for it are pointed out. 3 references

  20. Use of β-ray source for measurement of adsorption

    International Nuclear Information System (INIS)

    Kawakami, Hirokane; Nishimura, Keigo; Oshima, Takayoshi

    1987-01-01

    A research project has been carried out with the goal of determining the mass of a neutrino from β-decay measurements. During a study seeking the development of a β-ray source for this purpose, it was found that the amount of residual gas adsorbed on a cooled β-ray source can be measured successfully. Electrons emitted from a β-ray source is measured by an electron spectrometer. A sharp, nearly symmetric peak is obtained if all electrons have the same energy. If gas is adsorbed on the surface of the source, on the other hand, the resultant spectrum has a rather different profile due to energy loss caused by the gas. The difference between the energy loss spectrum and the original spectrum must be proportional to the amount of the adsorbed gas. In this study, a 109 Cd source with an electron energy peak at 18 keV is selected and the number of molecules adsorbed on the source, cooled to -35 deg C at 5 x 10 -7 Torr, is determined. Assuming that the gas is water vapor, it is shown that the adsorbed layer is of a two-molecular thickness on the average. It is also found that the thickness is reversible at varrying temperatures and does not change for two days. This gas amount is 7,500 time as large as that in the case of physical adsorption of water. (Nogami, K.)

  1. Radioactive Sources in Medicine: Impact of Additional Security Measures

    International Nuclear Information System (INIS)

    Classic, K. L.; Vetter, R. J.; Nelson, K. L.

    2004-01-01

    For many years, medical centers and hospitals have utilized appropriate security measures to prevent theft or unauthorized use of radioactive materials. Recent anxiety about orphan sources and terrorism has heightened concern about diversion of radioactive sources for purposes of constructing a radiological dispersion device. Some medical centers and hospitals may have responded by conducting threat assessments and incorporating additional measures into their security plans, but uniform recommendations or regulations have not been promulgated by regulatory agencies. The International Atomic Energy Agency drafted interim guidance for the purpose of assisting member states in deciding what security measures should be taken for various radioactive sources. The recommendations are aimed at regulators, but suppliers and users also may find the recommendations to be helpful. The purpose of this paper is to describe threat assessments and additional security actions that were taken by one large and one medium-sized medical center and the impact these measures had on operations. Both medical centers possess blood bank irradiators, low-dose-rate therapy sources, and Mo-99/Tc-99m generators that are common to many health care organizations. Other medical devices that were evaluated include high-dose-rate after loaders, intravascular brachytherapy sources, a Co-60 stereotactic surgery unit, and self-shielded irradiators used in biomedical research. This paper will discuss the impact additional security has had on practices that utilize these sources, cost of various security alternatives, and the importance of a security culture in assuring the integrity of security measures without negatively impacting beneficial use of these sources. (Author) 10 refs

  2. Inversion of Atmospheric Tracer Measurements, Localization of Sources

    Science.gov (United States)

    Issartel, J.-P.; Cabrit, B.; Hourdin, F.; Idelkadi, A.

    When abnormal concentrations of a pollutant are observed in the atmosphere, the question of its origin arises immediately. The radioactivity from Tchernobyl was de- tected in Sweden before the accident was announced. This situation emphasizes the psychological, political and medical stakes of a rapid identification of sources. In tech- nical terms, most industrial sources can be modeled as a fixed point at ground level with undetermined duration. The classical method of identification involves the cal- culation of a backtrajectory departing from the detector with an upstream integration of the wind field. We were first involved in such questions as we evaluated the ef- ficiency of the international monitoring network planned in the frame of the Com- prehensive Test Ban Treaty. We propose a new approach of backtracking based upon the use of retroplumes associated to available measurements. Firstly the retroplume is related to inverse transport processes, describing quantitatively how the air in a sam- ple originates from regions that are all the more extended and diffuse as we go back far in the past. Secondly it clarifies the sensibility of the measurement with respect to all potential sources. It is therefore calculated by adjoint equations including of course diffusive processes. Thirdly, the statistical interpretation, valid as far as sin- gle particles are concerned, should not be used to investigate the position and date of a macroscopic source. In that case, the retroplume rather induces a straightforward constraint between the intensity of the source and its position. When more than one measurements are available, including zero valued measurements, the source satisfies the same number of linear relations tightly related to the retroplumes. This system of linear relations can be handled through the simplex algorithm in order to make the above intensity-position correlation more restrictive. This method enables to manage in a quantitative manner the

  3. Development of negative heavy ion sources for plasma potential measurement

    International Nuclear Information System (INIS)

    Sasao, M.; Okabe, Y.; Fujisawa, A.; Iguchi, H.; Fujita, J.; Yamaoka, H.; Wada, M.

    1991-10-01

    A plasma sputter negative ion source was studied for its applicability to the potential measurement of a fusion plasma. Both the beam current density and the beam energy spread are key issues. Energy spectra of a self extracted Au - beam from the source were measured under the condition of a constant work function of the production surface. The full width of half maximum (FWHM) increases from 3 eV to 9 eV monotonically as the target voltage increases from 50 V to 300 V, independently from the target surface work function of 2.2 - 3 eV. (author)

  4. An optical distance sensor : tilt robust differential confocal measurement with mm range and nm uncertainty

    NARCIS (Netherlands)

    Cacace, L.A.

    2009-01-01

    Compared with conventional high-end optical systems, application of freeform optics offers many advantages. Their widespread use, however, is held back by the lack of a suitable measurement method.The NANOMEFOS project aims at realizing a universal freeform measurement machine to fill that void.The

  5. Measuring device for strong gamma-ray sources; Dispositif de mesure des fortes sources emettrices {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Engelman, J; Vagner, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    We are given the description of a hollow argon-filled cylindrical ionisation chamber which is to be used to measure gamma-emitting sources. The instrument is currently used at the Measures Department in routine gauging of some radioelements. Sources are introduced into the central part of the chamber through a remote handling device. Measures are directly registered, it is not worth while removing the source from the container; a deviation of the source has little effect on the ionization current. The chamber was gauged to test such elements as: {sup 198}Au, {sup 60}Co, {sup 192}Ir, {sup 24}Na, {sup 137}Cs. Its measuring power approximately ranges from 100 micro-curies to 5 curies. (author) [French] On decrit une chambre d'ionisation cylindrique creuse, a remplissage d'argon, destinee a la mesure des sources emettrices {gamma}. Cet appareil est utilise couramment par la Section Mesures pour l'etalonnage de routine d'un certain nombre de radioelements. Les sources sont mises en place au centre de la chambre par un dispositif de manipulation a distance. La mesure est faite directement, sans qu'il soit necessaire d'extraire la source de son container; un decentrement de la source n'a en effet pas d'influence sensible sur le courant d'ionisation. Cette chambre d'ionisation a ete etalonnee pour divers radioelements: {sup 198}Au, {sup 60}Co, {sup 192}Ir, {sup 24}Na, {sup 137}Cs. La flamme d'activite mesurable s'etend de 100 microcuries a 5 curies, environ. (auteur)

  6. Measurement of radiation skyshine with D-T neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, S.; Nishitani, T. E-mail: nisitani@naka.jaeri.go.jp; Ochiai, K.; Kaneko, J.; Hori, J.; Sato, S.; Yamauchi, M.; Tanaka, R.; Nakao, M.; Wada, M.; Wakisaka, M.; Murata, I.; Kutsukake, C.; Tanaka, S.; Sawamura, T.; Takahashi, A

    2003-09-01

    The D-T neutron skyshine experiments have been carried out at the Fusion Neutronics Source (FNS) of JAERI with the neutron yield of {approx}1.7x10{sup 11} n/s. The concrete thickness of the roof and the wall of a FNS target room are 1.15 and 2 m, respectively. The FNS skyshine port with a size of 0.9x0.9 m{sup 2} was open during the experimental period. The radiation dose rate outside the target room was measured a maximum distance of 550 m from the D-T target point with a spherical rem-counter. Secondary gamma-rays were measured with high purity Ge detectors and NaI scintillation counters. The highest neutron dose was about 9x10{sup -22} Sv/(source neutron) at a distance of 30 m from the D-T target point and the dose rate was attenuated to 4x10{sup -24} Sv/(source neutron) at a distance of 550 m. The measured neutron dose distribution was analyzed with Monte Carlo code MCNP-4B and a simple line source model. The MCNP calculation overestimates the neutron dose in the distance range larger than 230 m. The line source model agrees well with the experimental results within the distance of 350 m.

  7. Absorptivity Measurements and Heat Source Modeling to Simulate Laser Cladding

    Science.gov (United States)

    Wirth, Florian; Eisenbarth, Daniel; Wegener, Konrad

    The laser cladding process gains importance, as it does not only allow the application of surface coatings, but also additive manufacturing of three-dimensional parts. In both cases, process simulation can contribute to process optimization. Heat source modeling is one of the main issues for an accurate model and simulation of the laser cladding process. While the laser beam intensity distribution is readily known, the other two main effects on the process' heat input are non-trivial. Namely the measurement of the absorptivity of the applied materials as well as the powder attenuation. Therefore, calorimetry measurements were carried out. The measurement method and the measurement results for laser cladding of Stellite 6 on structural steel S 235 and for the processing of Inconel 625 are presented both using a CO2 laser as well as a high power diode laser (HPDL). Additionally, a heat source model is deduced.

  8. Radioactivity measurements of metallic 192Ir sources by calorimetric methods

    International Nuclear Information System (INIS)

    Genka, Tsuguo; Iwamoto, Seikichi; Takeuchi, Norio

    1992-01-01

    The necessity of establishing the traceability of dose measurement in brachytherapy 192 Ir sources is realized by physicians and researchers in the medical field. Standard sources of various shapes such as open-quotes hairpin,close quotes open-quotes single pin,close quotes open-quotes thin wire,close quotes and open-quotes seedclose quotes for calibrating ionization chambers in hospitals are being demanded. Nominal activities of not only these source products but also the standard sources have been so far specified by open-quotes apparentclose quotes values. Determination of open-quotes absoluteclose quotes activity by an established means such as 4pi-beta-gamma coincidence counting is not practical because quantitative dissolution of metallic iridium is very difficult. We tried to determine the open-quotes absoluteclose quotes activity by a calorimetric method in a fully nondestructive way

  9. Measurement-device-independent quantum communication with an untrusted source

    Science.gov (United States)

    Xu, Feihu

    2015-07-01

    Measurement-device-independent quantum key distribution (MDI-QKD) can provide enhanced security compared to traditional QKD, and it constitutes an important framework for a quantum network with an untrusted network server. Still, a key assumption in MDI-QKD is that the sources are trusted. We propose here a MDI quantum network with a single untrusted source. We have derived a complete proof of the unconditional security of MDI-QKD with an untrusted source. Using simulations, we have considered various real-life imperfections in its implementation, and the simulation results show that MDI-QKD with an untrusted source provides a key generation rate that is close to the rate of initial MDI-QKD in the asymptotic setting. Our work proves the feasibility of the realization of a quantum network. The network users need only low-cost modulation devices, and they can share both an expensive detector and a complicated laser provided by an untrusted network server.

  10. Measurement and correction of chromaticity in Hefei light source

    International Nuclear Information System (INIS)

    Sun Baogen; Xu Hongliang; He Duohui; Wang Junhua; Lu Ping

    2001-01-01

    The measurement and correction of chromaticity for Hefei light source is introduced. The natural chromaticity is obtained by detecting the variation of the betatron tune with the main dipole field strength. The correction chromaticity is obtained by detecting the variation of the betatron tune with the RF frequency. The theoretic analysis and formula for the two methods is given. The measurement results of chromaticity are given

  11. Do energy efficiency measures promote the use of renewable sources?

    International Nuclear Information System (INIS)

    Marques, Antonio C.; Fuinhas, Jose A.

    2011-01-01

    This paper analyses the factors behind the deployment of renewable energy, focusing particularly on the effect of energy efficiency policies and measures. The impact of these factors is appraised within the context of several phases of the use of renewable sources. We therefore apply the quantile regression technique to a set of 21 European Countries in two time spans: from 1990 to 1998, and from 1999 to 2006. We control variables of policy, environment, socioeconomic characteristics, and electricity generation. For the second period, energy efficiency policies and measures concerning renewable sources effectively promote renewables, namely in the take-off phase. We shed light on the lobbying effect of traditional energy industries, showing that it depends both on the period under analysis, and on the kind of traditional energy source.

  12. Spectroscopic measurements of an H- ion source discharge

    International Nuclear Information System (INIS)

    Keller, R.; Smith, H.V. Jr.

    1985-01-01

    Spectral emission lines from an H - Penning surface-plasma source (SPS), the 4X source, are examined in the visible and near ultraviolet. Electron distribution temperatures are deduced from integral line-strength measurements. These temperatures are surprisingly low, about 0.5 eV. Electron density values of about 1.5 x 10 14 cm -3 and H-atom energies between 2 and 2.6 eV are determined from the measured Balmer-line profiles. Assuming the H - energy is identical to the H-atom energy, an emittance limit of 0.006 π x cm x mrad is deduced for this source with a 5.4-mm aperture

  13. Miniature electron bombardment evaporation source: evaporation rate measurement

    International Nuclear Information System (INIS)

    Nehasil, V.; Masek, K.; Matolin, V.; Moreau, O.

    1997-01-01

    Miniature electron beam evaporation sources which operate on the principle of vaporization of source material, in the form of a tip, by electron bombardment are produced by several companies specialized in UHV equipment. These sources are used primarily for materials that are normally difficult to deposit due to their high evaporation temperature. They are appropriate for special applications such as heteroepitaxial thin film growth requiring a very low and well controlled deposition rate. A simple and easily applicable method of evaporation rate control is proposed. The method is based on the measurement of ion current produced by electron bombardment of evaporated atoms. The absolute evaporation flux values were measured by means of the Bayard-Alpert ion gauge, which enabled the ion current vs evaporation flux calibration curves to be plotted. (author). 1 tab., 4 figs., 6 refs

  14. Security measures in transport of radiation source in Jordan

    Energy Technology Data Exchange (ETDEWEB)

    Mohammad, Alslman [Korea Advanced Institute of Science and Technology, Kaist Daejeon (Korea, Republic of); Choi, Kwang Sik [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2011-05-15

    Radioactive materials are used in Jordan for peaceful applications in medicine, industry, agriculture, environmental science, education and research and military applications. Most of these radioactive sources used are imported, therefore trans-boundary movement is a significant factor in consideration of security measures during movement of these sources. After 11/9 2001 event, IAEA efforts began to focus and concentrate on security in transport of radioactive materials, after the emergence of risks of using these sources in terrorist activities. In 2002, Efforts were initiated by the IAEA to provide additional guidance for security in the transport of radioactive materials, based upon the new security requirements in the Recommendations on the Transport of Dangerous Goods. This paper reviews some of the measures relating to the transport of radioactive materials in Jordan

  15. Effects of neutron source type on soil moisture measurement

    Science.gov (United States)

    Irving Goldberg; Norman A. MacGillivray; Robert R. Ziemer

    1967-01-01

    A number of radioisotopes have recently become commercially available as alternatives to radium-225 in moisture gauging devices using alpha-neutron sources for determining soil moisture, for well logging, and for other industrial applications in which hydrogenous materials are measured.

  16. Source apportionment of hydrocarbons measured in the Eagle Ford shale

    Science.gov (United States)

    Roest, G. S.; Schade, G. W.

    2016-12-01

    The rapid development of unconventional oil and gas in the US has led to hydrocarbon emissions that are yet to be accurately quantified. Emissions from the Eagle Ford Shale in southern Texas, one of the most productive shale plays in the U.S., have received little attention due to a sparse air quality monitoring network, thereby limiting studies of air quality within the region. We use hourly atmospheric hydrocarbon and meteorological data from three locations in the Eagle Ford Shale to assess their sources. Data are available from the Texas commission of environmental quality (TCEQ) air quality monitors in Floresville, a small town southeast of San Antonio and just north of the shale area; and Karnes city, a midsize rural city in the center of the shale. Our own measurements were carried out at a private ranch in rural Dimmit County in southern Texas from April to November of 2015. Air quality monitor data from the TCEQ were selected for the same time period. Non-negative matrix factorization in R (package NMF) was used to determine likely sources and their contributions above background. While the TCEQ monitor data consisted mostly of hydrocarbons, our own data include both CO, CO2, O3, and NOx. We find that rural Dimmit County hydrocarbons are dominated by oil and gas development sources, while central shale hydrocarbons at the TCEQ monitoring sites have a mix of sources including car traffic. However, oil and gas sources also dominate hydrocarbons at Floresville and Karnes City. Toxic benzene is nearly exclusively due to oil and gas development sources, including flaring, which NMF identifies as a major hydrocarbon source in Karnes City. Other major sources include emissions of light weight alkanes (C2-C5) from raw natural gas emissions and a larger set of alkanes (C2-C10) from oil sources, including liquid storage tanks.

  17. Efficient color mixing through étendue conservation using freeform optics

    Science.gov (United States)

    Sorgato, Simone; Mohedano, Rubén.; Chaves, Julio; Cvetkovic, Aleksandra; Hernández, Maikel; Benitez, Pablo; Miñano, Juan C.; Thienpont, Hugo; Duerr, Fabian

    2015-08-01

    Today's SSL illumination market shows a clear trend to high flux packages with higher efficiency and higher CRI, realized by means of multiple color chips and phosphors. Such light sources require the optics to provide both near- and far-field color mixing. This design problem is particularly challenging for collimated luminaries, since traditional diffusers cannot be employed without enlarging the exit aperture and reducing brightness. Furthermore, diffusers compromise the light output ratio (efficiency) of the lamps to which they are applied. A solution, based on Köhler integration, consisting of a spherical cap comprising spherical microlenses on both its interior and exterior sides was presented in 2012. The diameter of this so-called Shell-Mixer was 3 times that of the chip array footprint. A new version of the Shell-Mixer, based on the Edge Ray Principle and conservation of etendue, where neither the outer shape of the cap nor the surfaces of the lenses are constrained to spheres or 2D Cartesian ovals will be shown in this work. The new shell is freeform, only twice as large as the original chip-array and equals the original model in terms of color uniformity, brightness and efficiency.

  18. Bayesian source term determination with unknown covariance of measurements

    Science.gov (United States)

    Belal, Alkomiet; Tichý, Ondřej; Šmídl, Václav

    2017-04-01

    Determination of a source term of release of a hazardous material into the atmosphere is a very important task for emergency response. We are concerned with the problem of estimation of the source term in the conventional linear inverse problem, y = Mx, where the relationship between the vector of observations y is described using the source-receptor-sensitivity (SRS) matrix M and the unknown source term x. Since the system is typically ill-conditioned, the problem is recast as an optimization problem minR,B(y - Mx)TR-1(y - Mx) + xTB-1x. The first term minimizes the error of the measurements with covariance matrix R, and the second term is a regularization of the source term. There are different types of regularization arising for different choices of matrices R and B, for example, Tikhonov regularization assumes covariance matrix B as the identity matrix multiplied by scalar parameter. In this contribution, we adopt a Bayesian approach to make inference on the unknown source term x as well as unknown R and B. We assume prior on x to be a Gaussian with zero mean and unknown diagonal covariance matrix B. The covariance matrix of the likelihood R is also unknown. We consider two potential choices of the structure of the matrix R. First is the diagonal matrix and the second is a locally correlated structure using information on topology of the measuring network. Since the inference of the model is intractable, iterative variational Bayes algorithm is used for simultaneous estimation of all model parameters. The practical usefulness of our contribution is demonstrated on an application of the resulting algorithm to real data from the European Tracer Experiment (ETEX). This research is supported by EEA/Norwegian Financial Mechanism under project MSMT-28477/2014 Source-Term Determination of Radionuclide Releases by Inverse Atmospheric Dispersion Modelling (STRADI).

  19. Three-dimensional printing of freeform helical microstructures: a review.

    Science.gov (United States)

    Farahani, R D; Chizari, K; Therriault, D

    2014-09-21

    Three-dimensional (3D) printing is a fabrication method that enables creation of structures from digital models. Among the different structures fabricated by 3D printing methods, helical microstructures attracted the attention of the researchers due to their potential in different fields such as MEMS, lab-on-a-chip systems, microelectronics and telecommunications. Here we review different types of 3D printing methods capable of fabricating 3D freeform helical microstructures. The techniques including two more common microfabrication methods (i.e., focused ion beam chemical vapour deposition and microstereolithography) and also five methods based on computer-controlled robotic direct deposition of ink filament (i.e., fused deposition modeling, meniscus-confined electrodeposition, conformal printing on a rotating mandrel, UV-assisted and solvent-cast 3D printings) and their advantages and disadvantages regarding their utilization for the fabrication of helical microstructures are discussed. Focused ion beam chemical vapour deposition and microstereolithography techniques enable the fabrication of very precise shapes with a resolution down to ∼100 nm. However, these techniques may have material constraints (e.g., low viscosity) and/or may need special process conditions (e.g., vacuum chamber) and expensive equipment. The five other techniques based on robotic extrusion of materials through a nozzle are relatively cost-effective, however show lower resolution and less precise features. The popular fused deposition modeling method offers a wide variety of printable materials but the helical microstructures manufactured featured a less precise geometry compared to the other printing methods discussed in this review. The UV-assisted and the solvent-cast 3D printing methods both demonstrated high performance for the printing of 3D freeform structures such as the helix shape. However, the compatible materials used in these methods were limited to UV-curable polymers and

  20. Dynamic Aperture Measurements at the Advanced Light Source

    International Nuclear Information System (INIS)

    Decking, W.; Robin, D.

    1999-01-01

    A large dynamic aperture for a storage ring is of importance for long lifetimes and a high injection efficiency. Measurements of the dynamic aperture of the third generation synchrotron light source Advanced Light Source (ALS) using beam excitation with kicker magnets are presented. The experiments were done for various accelerator conditions, allowing us to investigate the influence of different working points, chromaticities, insertion devices, etc.. The results are compared both with tracking calculations and a simple model for the dynamic aperture yielding good agreements. This gives us confidence in the predictability of the nonlinear accelerator model. This is especially important for future ALS upgrades as well as new storage ring designs

  1. Study of localized photon source in space of measures

    International Nuclear Information System (INIS)

    Lisi, M.

    2010-01-01

    In this paper we study a three-dimensional photon transport problem in an interstellar cloud, with a localized photon source inside. The problem is solved indirectly, by defining the adjoint of an operator acting on an appropriate space of continuous functions. By means of sun-adjoint semi groups theory of operators in a Banach space of regular Borel measures, we prove existence and uniqueness of the solution of the problem. A possible approach to identify the localization of the photon source is finally proposed.

  2. The error sources appearing for the gamma radioactive source measurement in dynamic condition

    International Nuclear Information System (INIS)

    Sirbu, M.

    1977-01-01

    The error analysis for the measurement of the gamma radioactive sources, placed on the soil, with the help of the helicopter are presented. The analysis is based on a new formula that takes account of the attenuation gamma ray factor in the helicopter walls. They give a complete error formula and an error diagram. (author)

  3. Absolute measurement of LDR brachytherapy source emitted power: Instrument design and initial measurements.

    Science.gov (United States)

    Malin, Martha J; Palmer, Benjamin R; DeWerd, Larry A

    2016-02-01

    Energy-based source strength metrics may find use with model-based dose calculation algorithms, but no instruments exist that can measure the energy emitted from low-dose rate (LDR) sources. This work developed a calorimetric technique for measuring the power emitted from encapsulated low-dose rate, photon-emitting brachytherapy sources. This quantity is called emitted power (EP). The measurement methodology, instrument design and performance, and EP measurements made with the calorimeter are presented in this work. A calorimeter operating with a liquid helium thermal sink was developed to measure EP from LDR brachytherapy sources. The calorimeter employed an electrical substitution technique to determine the power emitted from the source. The calorimeter's performance and thermal system were characterized. EP measurements were made using four (125)I sources with air-kerma strengths ranging from 2.3 to 5.6 U and corresponding EPs of 0.39-0.79 μW, respectively. Three Best Medical 2301 sources and one Oncura 6711 source were measured. EP was also computed by converting measured air-kerma strengths to EPs through Monte Carlo-derived conversion factors. The measured EP and derived EPs were compared to determine the accuracy of the calorimeter measurement technique. The calorimeter had a noise floor of 1-3 nW and a repeatability of 30-60 nW. The calorimeter was stable to within 5 nW over a 12 h measurement window. All measured values agreed with derived EPs to within 10%, with three of the four sources agreeing to within 4%. Calorimeter measurements had uncertainties ranging from 2.6% to 4.5% at the k = 1 level. The values of the derived EPs had uncertainties ranging from 2.9% to 3.6% at the k = 1 level. A calorimeter capable of measuring the EP from LDR sources has been developed and validated for (125)I sources with EPs between 0.43 and 0.79 μW.

  4. Lunar occultations for gamma-ray source measurements

    Science.gov (United States)

    Koch, David G.; Hughes, E. B.; Nolan, Patrick L.

    1990-01-01

    The unambiguous association of discrete gamma-ray sources with objects radiating at other wavelengths, the separation of discrete sources from the extended emission within the Galaxy, the mapping of gamma-ray emission from nearby galaxies and the measurement of structure within a discrete source cannot presently be accomplished at gamma-ray energies. In the past, the detection processes used in high-energy gamma-ray astronomy have not allowed for good angular resolution. This problem can be overcome by placing gamma-ray detectors on the moon and using the horizon as an occulting edge to achieve arcsec resolution. For purposes of discussion, this concept is examined for gamma rays above 100 MeV for which pair production dominates the detection process and locally-generated nuclear gamma rays do not contribute to the background.

  5. Comparison of optical design methods of freeform surfaces for imaging applications

    Science.gov (United States)

    Agócs, Tibor

    2015-09-01

    Optical systems based on freeform optical components offer many advantages over conventional systems in imaging applications, e.g. superior image quality, compact and lightweight designs. There are a few well established manufacturing method that can be used for the generation of freeform surfaces with low surface form error and low surface roughness, in the case of freeform mirrors e.g. diamond turning, nickel plating and post-polishing. Metrology is evolving rapidly, although developments are still needed in order to verify the manufactured surface with the necessary accuracy. Optical design methods of freeform surfaces are also lagging behind, many algorithms address non-imaging applications, but in the field of imaging (image-forming) only a few exists and works with various limitations. We compare the available techniques in freeform optical design for imaging and explore the advantages, disadvantages and boundary conditions of the different methods. We also intend to identify the most useful concepts and investigate how they can be embedded into commercially available optical design software.

  6. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yuan-Pei; Zhang, Bing, E-mail: yypspore@gmail.com, E-mail: zhang@physics.unlv.edu [Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China)

    2017-09-20

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  7. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    International Nuclear Information System (INIS)

    Yang, Yuan-Pei; Zhang, Bing

    2017-01-01

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  8. The rotation measures of radio sources and their interpretation

    International Nuclear Information System (INIS)

    Vallee, J.P.; Kronberg, P.P.

    1975-01-01

    Rotation measures of 251 discrete radio sources have been determined after incorporating new polarization data at short wavelenghts. These have been applied to a 'slab' model-fitting technique to determine the most likely spiral arm magnetic field structure. The best agreement is obtained for a longitudinal spiral arm magnetic field, directed toward (lII approximately 90 0 , bII approximately 0 0 ), but perturbed by an anomaly towards the North Galactic Spur. (orig.) [de

  9. Bayesian statistics in radionuclide metrology: measurement of a decaying source

    International Nuclear Information System (INIS)

    Bochud, F. O.; Bailat, C.J.; Laedermann, J.P.

    2007-01-01

    The most intuitive way of defining a probability is perhaps through the frequency at which it appears when a large number of trials are realized in identical conditions. The probability derived from the obtained histogram characterizes the so-called frequentist or conventional statistical approach. In this sense, probability is defined as a physical property of the observed system. By contrast, in Bayesian statistics, a probability is not a physical property or a directly observable quantity, but a degree of belief or an element of inference. The goal of this paper is to show how Bayesian statistics can be used in radionuclide metrology and what its advantages and disadvantages are compared with conventional statistics. This is performed through the example of an yttrium-90 source typically encountered in environmental surveillance measurement. Because of the very low activity of this kind of source and the small half-life of the radionuclide, this measurement takes several days, during which the source decays significantly. Several methods are proposed to compute simultaneously the number of unstable nuclei at a given reference time, the decay constant and the background. Asymptotically, all approaches give the same result. However, Bayesian statistics produces coherent estimates and confidence intervals in a much smaller number of measurements. Apart from the conceptual understanding of statistics, the main difficulty that could deter radionuclide metrologists from using Bayesian statistics is the complexity of the computation. (authors)

  10. Timing jitter measurements at the SLC electron source

    International Nuclear Information System (INIS)

    Sodja, J.; Browne, M.J.; Clendenin, J.E.

    1989-03-01

    The SLC thermionic gun and electron source produce a beam of up to 15 /times/ 10 10 /sub e//minus/ in a single S-band bunch. A 170 keV, 2 ns FWHM pulse out of the gun is compressed by means of two subharmonic buncher cavities followed by an S-band buncher and a standard SLAC accelerating section. Ceramic gaps in the beam pipe at the output of the gun allow a measure of the beam intensity and timing. A measurement at these gaps of the timing jitter, with a resolution of <10 ps, is described. 3 refs., 5 figs

  11. Parametric design of a part with free-form surfaces

    Institute of Scientific and Technical Information of China (English)

    KIM Yeoung-il; KIM Li-ra; JUN Cha-soo

    2006-01-01

    3D solid models for parts with regular-form surfaces (PRFSs) are effectively generated using traditional parametric design techniques. A new model is obtained by changing some parameters defining the model. The parts with free-form surfaces(PFFSs), however, cannot be defined by several parameters. Usually they are defined by some geometric elements like profile curves. The traditional parametric design approaches have not easily dealt with the PFFSs. A method for generating a solid model and an engineering drawing for PFFSs is proposed in this paper: First, the new profiles are generated from input point data. Second,the profile information is extracted from the existing model. Last, the old profiles are replaced with the new profiles. This method can preserve the associative information of the existing model and automatically generate the drawing including views, dimensions, and annotations. The proposed method has been implemented using a commercial CAD/CAM system, Unigraphics, and API functions written in C-language, and were applied to the blades of a turbine generator. Some illustrative examples are provided in order to show the effectiveness of the proposed method.

  12. Electron Beam Freeform Fabrication of Titanium Alloy Gradient Structures

    Science.gov (United States)

    Brice, Craig A.; Newman, John A.; Bird, Richard Keith; Shenoy, Ravi N.; Baughman, James M.; Gupta, Vipul K.

    2014-01-01

    Historically, the structural optimization of aerospace components has been done through geometric methods. A monolithic material is chosen based on the best compromise between the competing design limiting criteria. Then the structure is geometrically optimized to give the best overall performance using the single material chosen. Functionally graded materials offer the potential to further improve structural efficiency by allowing the material composition and/or microstructural features to spatially vary within a single structure. Thus, local properties could be tailored to the local design limiting criteria. Additive manufacturing techniques enable the fabrication of such graded materials and structures. This paper presents the results of a graded material study using two titanium alloys processed using electron beam freeform fabrication, an additive manufacturing process. The results show that the two alloys uniformly mix at various ratios and the resultant static tensile properties of the mixed alloys behave according to rule-of-mixtures. Additionally, the crack growth behavior across an abrupt change from one alloy to the other shows no discontinuity and the crack smoothly transitions from one crack growth regime into another.

  13. Quantitative optimization of solid freeform deposition of aqueous hydrogels

    International Nuclear Information System (INIS)

    Kang, K H; Hockaday, L A; Butcher, J T

    2013-01-01

    Many soft tissues exhibit complex anatomical geometry that is challenging to replicate for regenerative medicine applications. Solid freeform fabrication (SFF) has emerged as an attractive approach for creating 3D tissues, but a detailed understanding of how specific fabrication parameters affect accuracy and viability has not been established to date. In this study, we evaluate the effects of printing parameters of the Fab-Home 3D printing system on accuracy using alginate, photocrosslinkable polyethylene-glycol diacrylate (PEG-DA) and gelatin as commonly used model hydrogel materials. Print accuracy and resolution along the length, width and height were determined based on quantitative image analysis. The effects of extrusion parameters on cell viability were assessed using porcine aortic valve interstitial cells (PAVIC) as a model cell type. We observed that pressure, pathheight and pathspace all significantly affected print accuracy and resolution. Printing conditions did not affect PAVIC viability within the ranges applied. We predicted that optimal pressure, pathheight and pathspace values would be increased linearly with increasing nozzle diameter, and we confirmed that the predicted values generate accurate 3D geometries while poorly chosen parameters yield inaccurate, unpredictable geometries. This systematic optimization strategy therefore improves the accuracy of 3D printing platforms for biofabrication and tissue engineering applications. (paper)

  14. A gamma-source method of measuring soil moisture

    International Nuclear Information System (INIS)

    Al-Jeboori, M.A.; Ameen, I.A.

    1986-01-01

    Water content in soil column was measured using NaI scintillation detector 5 mci Cs-137 as a gamma source. The measurements were done with a back scatter gauge, restricted with scattering angle less to than /2 overcome the effect of soil type. A 3 cm air gap was maintained between the front of the detector and the wall of the soil container in order to increase the counting rate. The distance between the center of the source and the center of the back scattering detector was 14 cm. The accuracy of the measurements was 0.63. For comparision, a direct rays method was used to measure the soil moisture. The results gave an error of 0.65. Results of the two methods were compared with the gravimetric method which gave an error of 0.18 g/g and 0.17 g/g for direct and back method respectively. The quick direct method was used to determine the gravimetric and volumetric percentage constants, and were found to be 1.62 and 0.865 respectively. The method then used to measure the water content in the layers of soil column.(6 tabs., 4 figs., 12 refs.)

  15. Closed-Loop Process Control for Electron Beam Freeform Fabrication and Deposition Processes

    Science.gov (United States)

    Taminger, Karen M. (Inventor); Hafley, Robert A. (Inventor); Martin, Richard E. (Inventor); Hofmeister, William H. (Inventor)

    2013-01-01

    A closed-loop control method for an electron beam freeform fabrication (EBF(sup 3)) process includes detecting a feature of interest during the process using a sensor(s), continuously evaluating the feature of interest to determine, in real time, a change occurring therein, and automatically modifying control parameters to control the EBF(sup 3) process. An apparatus provides closed-loop control method of the process, and includes an electron gun for generating an electron beam, a wire feeder for feeding a wire toward a substrate, wherein the wire is melted and progressively deposited in layers onto the substrate, a sensor(s), and a host machine. The sensor(s) measure the feature of interest during the process, and the host machine continuously evaluates the feature of interest to determine, in real time, a change occurring therein. The host machine automatically modifies control parameters to the EBF(sup 3) apparatus to control the EBF(sup 3) process in a closed-loop manner.

  16. Multi-scale freeform surface texture filtering using a mesh relaxation scheme

    International Nuclear Information System (INIS)

    Jiang, Xiangqian; Abdul-Rahman, Hussein S; Scott, Paul J

    2013-01-01

    Surface filtering algorithms using Fourier, Gaussian, wavelets, etc, are well-established for simple Euclidean geometries. However, these filtration techniques cannot be applied to today's complex freeform surfaces, which have non-Euclidean geometries, without distortion of the results. This paper proposes a new multi-scale filtering algorithm for freeform surfaces that are represented by triangular meshes based on a mesh relaxation scheme. The proposed algorithm is capable of decomposing a freeform surface into different scales and separating surface roughness, waviness and form from each other, as will be demonstrated throughout the paper. Results of applying the proposed algorithm to computer-generated as well as real surfaces are represented and compared with a lifting wavelet filtering algorithm. (paper)

  17. Evaluating the performance of free-formed surface parts using an analytic network process

    Science.gov (United States)

    Qian, Xueming; Ma, Yanqiao; Liang, Dezhi

    2018-03-01

    To successfully design parts with a free-formed surface, the critical issue of how to evaluate and select a favourable evaluation strategy before design is raised. The evaluation of free-formed surface parts is a multiple criteria decision-making (MCDM) problem that requires the consideration of a large number of interdependent factors. The analytic network process (ANP) is a relatively new MCDM method that can systematically deal with all kinds of dependences. In this paper, the factors, which come from the life-cycle and influence the design of free-formed surface parts, are proposed. After analysing the interdependence among these factors, a Hybrid ANP (HANP) structure for evaluating the part’s curved surface is constructed. Then, a HANP evaluation of an impeller is presented to illustrate the application of the proposed method.

  18. New strategies and developments in transparent free-form design: From facetted to nearly smooth envelopes

    KAUST Repository

    Baldassini, Niccolo

    2009-09-01

    Free-form geometries in architecture pose new challenges to designers and engineers. Form, structure and fabrication processes are closely linked, which makes the realization of complex architectural free-form structures even harder. Free-form transparent design today is mainly based on triangularly facetted forms or quadrilateral meshes supported by a structure composed of rectilinear bars, with strong shape restrictions. After a brief review of the history, we report on some very recent progress in this area. Beginning with a presentation of improved methods for triangle mesh design, we also discuss experiences in coupling triangular glass panels with continuous curved structures, seeking an optimised structural behaviour and simplified connections. Furthermore, we present how the results of research on planar quadrilateral (PQ) meshes lead the way to optimized beam layouts and the breakdown of free-form shapes using planar quadrilateral panels. PQ meshes are rooted in discrete differential geometry, an active area of mathematical research. Using recent projects as examples, we discuss how transparent free-form envelopes with a smooth visual appearance are achievable if the structure is designed to adhere to the limits of current glazing technology and the surfaces are reasonably simple (e.g. rotational, overall developable, or of a small scale). In section 6 we show how the latter restriction can be relaxed: the theoretical and computational methodology for PQ meshes can easily be extended to create nearly smooth approximations of free-form surfaces by single-curved panels. This has a strong impact on glass panelling design, since it avoids expensive double-curvature glass and exploits cold-bending technology. We elaborate on how this discretisation technique goes hand in hand with the technology for construction of the structure, glazing system and structural joints. Our approach has been tested in three case studies, each one validating a particular aspect of

  19. Design of multisegmented freeform lens for LED fishing/working lamp with high efficiency.

    Science.gov (United States)

    Lai, Min-Feng; Anh, Nguyen Doan Quoc; Gao, Jia-Zhi; Ma, Hsin-Yi; Lee, Hsiao-Yi

    2015-10-01

    A novel LED fishing/working light is proposed to enhance the lighting efficiency of a fishing boat. The study is focused on the freeform secondary lens design so as to create a lamp that attracts fish and sheds light on the deck for the crew's work. The experimental results show that the proposed multisegmented freeform lens can deliver the proposed aim, giving 3 times as much illuminating power as the traditional high-intensity discharge fishing lamp does with the same input of electrical power.

  20. Analytic free-form lens design for imaging applications with high aspect ratio

    Science.gov (United States)

    Duerr, Fabian; Benítez, Pablo; Miñano, Juan Carlos; Meuret, Youri; Thienpont, Hugo

    2012-10-01

    A new three-dimensional analytic optics design method is presented that enables the coupling of three ray sets with only two free-form lens surfaces. Closely related to the Simultaneous Multiple Surface method in three dimensions (SMS3D), it is derived directly from Fermat's principle, leading to multiple sets of functional differential equations. The general solution of these equations makes it possible to calculate more than 80 coefficients for each implicit surface function. Ray tracing simulations of these free-form lenses demonstrate superior imaging performance for applications with high aspect ratio, compared to conventional rotational symmetric systems.

  1. Geometric buckling measurements using the pulsed neutron source method

    Energy Technology Data Exchange (ETDEWEB)

    Sjoestrand, N G; Mednis, J; Nilsson, T

    1959-03-15

    The geometric buckling of cylindrical reactors with one or both ends rounded has been determined by pulsed source measurements with small polyethylene geometries. The results were in general accord with theoretical calculations. The diffusion parameters of polyethylene were also determined. The diffusion length was 2.12 {+-} 0.03 cm, and for the capture cross section of hydrogen a value of 0.337 {+-} 0.005 barns was found. The effect of control rods was studied using thin cadmium rods in water. Good agreement was found for axial, central rods, whereas the theoretical predictions for the effect of diagonal rods were too high.

  2. Geometric buckling measurements using the pulsed neutron source method

    International Nuclear Information System (INIS)

    Sjoestrand, N.G.; Mednis, J.; Nilsson, T.

    1959-03-01

    The geometric buckling of cylindrical reactors with one or both ends rounded has been determined by pulsed source measurements with small polyethylene geometries. The results were in general accord with theoretical calculations. The diffusion parameters of polyethylene were also determined. The diffusion length was 2.12 ± 0.03 cm, and for the capture cross section of hydrogen a value of 0.337 ± 0.005 barns was found. The effect of control rods was studied using thin cadmium rods in water. Good agreement was found for axial, central rods, whereas the theoretical predictions for the effect of diagonal rods were too high

  3. Wavelet based free-form deformations for nonrigid registration

    Science.gov (United States)

    Sun, Wei; Niessen, Wiro J.; Klein, Stefan

    2014-03-01

    In nonrigid registration, deformations may take place on the coarse and fine scales. For the conventional B-splines based free-form deformation (FFD) registration, these coarse- and fine-scale deformations are all represented by basis functions of a single scale. Meanwhile, wavelets have been proposed as a signal representation suitable for multi-scale problems. Wavelet analysis leads to a unique decomposition of a signal into its coarse- and fine-scale components. Potentially, this could therefore be useful for image registration. In this work, we investigate whether a wavelet-based FFD model has advantages for nonrigid image registration. We use a B-splines based wavelet, as defined by Cai and Wang.1 This wavelet is expressed as a linear combination of B-spline basis functions. Derived from the original B-spline function, this wavelet is smooth, differentiable, and compactly supported. The basis functions of this wavelet are orthogonal across scales in Sobolev space. This wavelet was previously used for registration in computer vision, in 2D optical flow problems,2 but it was not compared with the conventional B-spline FFD in medical image registration problems. An advantage of choosing this B-splines based wavelet model is that the space of allowable deformation is exactly equivalent to that of the traditional B-spline. The wavelet transformation is essentially a (linear) reparameterization of the B-spline transformation model. Experiments on 10 CT lung and 18 T1-weighted MRI brain datasets show that wavelet based registration leads to smoother deformation fields than traditional B-splines based registration, while achieving better accuracy.

  4. Advanced freeform optics enabling ultra-compact VR headsets

    Science.gov (United States)

    Benitez, Pablo; Miñano, Juan C.; Zamora, Pablo; Grabovičkić, Dejan; Buljan, Marina; Narasimhan, Bharathwaj; Gorospe, Jorge; López, Jesús; Nikolić, Milena; Sánchez, Eduardo; Lastres, Carmen; Mohedano, Ruben

    2017-06-01

    We present novel advanced optical designs with a dramatically smaller display to eye distance, excellent image quality and a large field of view (FOV). This enables headsets to be much more compact, typically occupying about a fourth of the volume of a conventional headset with the same FOV. The design strategy of these optics is based on a multichannel approach, which reduces the distance from the eye to the display and the display size itself. Unlike conventional microlens arrays, which are also multichannel devices, our designs use freeform optical surfaces to produce excellent imaging quality in the entire field of view, even when operating at very oblique incidences. We present two families of compact solutions that use different types of lenslets: (1) refractive designs, whose lenslets are composed typically of two refractive surfaces each; and (2) light-folding designs that use prism-like three-surface lenslets, in which rays undergo refraction, reflection, total internal reflection and refraction again. The number of lenslets is not fixed, so different configurations may arise, adaptable for flat or curved displays with different aspect ratios. In the refractive designs the distance between the optics and the display decreases with the number of lenslets, allowing for displaying a light-field when the lenslet becomes significantly small than the eye pupil. On the other hand, the correlation between number of lenslets and the optics to display distance is broken in light-folding designs, since their geometry permits achieving a very short display to eye distance with even a small number of lenslets.

  5. PWFA plasma source - interferometric diagnostics for Li vapor density measurements

    International Nuclear Information System (INIS)

    Sivakumaran, V.; Mohandas, K.K.; Singh, Sneha; Ravi Kumar, A.V.

    2015-01-01

    A prototype (40 cm long) plasma source based on Li heat pipe oven has been developed for the Plasma Wakefield Acceleration (PWFA) experiments at IPR (IPR), Gujarat as a part of the ongoing Accelerator Programme. Li vapor in the oven is produced by heating solid Li in helium buffer gas. A uniform column of Li plasma is generated by UV photo ionization (193 nm) of the Li vapor in the heat pipe oven. In these experiments, an accurate measurement of Li vapor density is important as it has got a direct consequence on the plasma electron density. In the present experiment, the vapor density is measured optically by using Hook method (spectrally resolved white light interferometry). The hook like structure formed near the vicinity of the Li 670.8 nm resonance line was recorded with a white light Mach Zehnder interferometer crossed with an imaging spectrograph to estimate the Li vapor density. The vapor density measurements have been carried out as a function of external oven temperature and the He buffer gas pressure. This technique has the advantage of being insensitive to line broadening and line shape, and its high dynamic range even with optically thick absorption line. Here, we present the line integrated Lithium vapor density measurement using Hook method and also compare the same with other optical diagnostic techniques (White light absorption and UV absorption) for Li vapor density measurements. (author)

  6. Gasdynamic measurements for the LASL intense neutron source

    International Nuclear Information System (INIS)

    Johnston, S.C.

    1978-02-01

    Measurements made on a two-dimensional simulation of the Los Alamos Scientific Laboratory (LASL) Intense Neutron Source (INS) experiment are discussed. The purpose of this work was to characterize the supersonic INS channel flow under conditions of large amounts of energy deposition. Nozzle channel wall pressure measurements, cold flow leakage rates, vacuum channel pressure and Mach number, leakage flow rates with mass addition to and momentum extraction from the main flow, and flow visualization photographs are given. Energy addition up to thirty percent of the theoretical maximum was achieved via mass addition to and momentum extraction from the main channel flow. In this range, both a weak and strong regime for leakage flow were identified. These regimes differed by about twenty percent in leakage flow rates

  7. Spectroscopic measurements of anode plasma with cryogenic pulsed ion sources

    International Nuclear Information System (INIS)

    Yoneda, H.; Urata, T.; Ohbayashi, K.; Kim, Y.; Horioka, K.; Kasuya, K.

    1987-01-01

    In ion beam diodes, electromagnetic wave is coupled to ion beam. Ion is extracted from anode plasma, which is produced early in the power pulse. However, exact mechanism of anode plasma production, expansion and ion extraction process is unknown. In particularly, anode plasma expansion is seemed to be one of the reasons of rapid impedance collapse of the diode, which is serious problem in high power experiments. Some experimental results showed that anode plasma expansion velocity was about 5 times larger than that inferred from simple thermal velocity. Several explanations for these results were proposed; for example, electron collisionarity in anode plasma, fast neutral gas particle, diamagnetism. To solve this question, it is necessary to measure the characteristic of anode plasma with space and time resolution. The authors made spectroscopic measurements to investigate variety of electron temperature, electron density, expansion velocity of anode plasma with various ion sources

  8. Greenhouse Gas Source Attribution: Measurements Modeling and Uncertainty Quantification

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhen [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Safta, Cosmin [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Sargsyan, Khachik [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Najm, Habib N. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); van Bloemen Waanders, Bart Gustaaf [Sandia National Lab. (SNL-CA), Livermore, CA (United States); LaFranchi, Brian W. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Ivey, Mark D. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Schrader, Paul E. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Michelsen, Hope A. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Bambha, Ray P. [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2014-09-01

    In this project we have developed atmospheric measurement capabilities and a suite of atmospheric modeling and analysis tools that are well suited for verifying emissions of green- house gases (GHGs) on an urban-through-regional scale. We have for the first time applied the Community Multiscale Air Quality (CMAQ) model to simulate atmospheric CO2 . This will allow for the examination of regional-scale transport and distribution of CO2 along with air pollutants traditionally studied using CMAQ at relatively high spatial and temporal resolution with the goal of leveraging emissions verification efforts for both air quality and climate. We have developed a bias-enhanced Bayesian inference approach that can remedy the well-known problem of transport model errors in atmospheric CO2 inversions. We have tested the approach using data and model outputs from the TransCom3 global CO2 inversion comparison project. We have also performed two prototyping studies on inversion approaches in the generalized convection-diffusion context. One of these studies employed Polynomial Chaos Expansion to accelerate the evaluation of a regional transport model and enable efficient Markov Chain Monte Carlo sampling of the posterior for Bayesian inference. The other approach uses de- terministic inversion of a convection-diffusion-reaction system in the presence of uncertainty. These approaches should, in principle, be applicable to realistic atmospheric problems with moderate adaptation. We outline a regional greenhouse gas source inference system that integrates (1) two ap- proaches of atmospheric dispersion simulation and (2) a class of Bayesian inference and un- certainty quantification algorithms. We use two different and complementary approaches to simulate atmospheric dispersion. Specifically, we use a Eulerian chemical transport model CMAQ and a Lagrangian Particle Dispersion Model - FLEXPART-WRF. These two models share the same WRF

  9. sources

    Directory of Open Access Journals (Sweden)

    Shu-Yin Chiang

    2002-01-01

    Full Text Available In this paper, we study the simplified models of the ATM (Asynchronous Transfer Mode multiplexer network with Bernoulli random traffic sources. Based on the model, the performance measures are analyzed by the different output service schemes.

  10. Mesh-free free-form lensing - I. Methodology and application to mass reconstruction

    Science.gov (United States)

    Merten, Julian

    2016-09-01

    Many applications and algorithms in the field of gravitational lensing make use of meshes with a finite number of nodes to analyse and manipulate data. Specific examples in lensing are astronomical CCD images in general, the reconstruction of density distributions from lensing data, lens-source plane mapping or the characterization and interpolation of a point spread function. We present a numerical framework to interpolate and differentiate in the mesh-free domain, defined by nodes with coordinates that follow no regular pattern. The framework is based on radial basis functions (RBFs) to smoothly represent data around the nodes. We demonstrate the performance of Gaussian RBF-based, mesh-free interpolation and differentiation, which reaches the sub-percent level in both cases. We use our newly developed framework to translate ideas of free-form mass reconstruction from lensing on to the mesh-free domain. By reconstructing a simulated mock lens we find that strong-lensing only reconstructions achieve <10 per cent accuracy in the areas where these constraints are available but provide poorer results when departing from these regions. Weak-lensing only reconstructions give <10 per cent accuracy outside the strong-lensing regime, but cannot resolve the inner core structure of the lens. Once both regimes are combined, accurate reconstructions can be achieved over the full field of view. The reconstruction of a simulated lens, using constraints that mimics real observations, yields accurate results in terms of surface-mass density, Navarro-Frenk-White profile (NFW) parameters, Einstein radius and magnification map recovery, encouraging the application of this method to real data.

  11. 3D Printing PDMS Elastomer in a Hydrophilic Support Bath via Freeform Reversible Embedding.

    Science.gov (United States)

    Hinton, Thomas J; Hudson, Andrew; Pusch, Kira; Lee, Andrew; Feinberg, Adam W

    2016-10-10

    Polydimethylsiloxane (PDMS) elastomer is used in a wide range of biomaterial applications including microfluidics, cell culture substrates, flexible electronics, and medical devices. However, it has proved challenging to 3D print PDMS in complex structures due to its low elastic modulus and need for support during the printing process. Here we demonstrate the 3D printing of hydrophobic PDMS prepolymer resins within a hydrophilic Carbopol gel support via freeform reversible embedding (FRE). In the FRE printing process, the Carbopol support acts as a Bingham plastic that yields and fluidizes when the syringe tip of the 3D printer moves through it, but acts as a solid for the PDMS extruded within it. This, in combination with the immiscibility of hydrophobic PDMS in the hydrophilic Carbopol, confines the PDMS prepolymer within the support for curing times up to 72 h while maintaining dimensional stability. After printing and curing, the Carbopol support gel releases the embedded PDMS prints by using phosphate buffered saline solution to reduce the Carbopol yield stress. As proof-of-concept, we used Sylgard 184 PDMS to 3D print linear and helical filaments via continuous extrusion and cylindrical and helical tubes via layer-by-layer fabrication. Importantly, we show that the 3D printed tubes were manifold and perfusable. The results demonstrate that hydrophobic polymers with low viscosity and long cure times can be 3D printed using a hydrophilic support, expanding the range of biomaterials that can be used in additive manufacturing. Further, by implementing the technology using low cost open-source hardware and software tools, the FRE printing technique can be rapidly implemented for research applications.

  12. Student Evaluation of Teaching: A Study Exploring Student Rating Instrument Free-Form Text Comments

    Science.gov (United States)

    Stupans, Ieva; McGuren, Therese; Babey, Anna Marie

    2016-01-01

    Student rating instruments are recognised to be valid indicators of effective instruction, providing a valuable tool to improve teaching. However, free-form text comments obtained from the open-ended question component of such surveys are only infrequently analysed comprehensively. We employed an innovative, systematic approach to the analysis of…

  13. Solid freeform fabrication of piezoelectric actuators by a micro-casting method

    NARCIS (Netherlands)

    Bos, B.; Gorter, H.; Dortmans, L.J.M.G.

    2004-01-01

    In recent years, there has been much interest in the manufacturing of piezoceramic actuators by Solid Freeform Fabrication (SFF) methods, following developments in polymer and metal shaping. With these methods, actuator shapes can be realized that are impossible or very difficult to obtain by

  14. Integrated Front–Rear-Grid Optimization of Free-Form Solar Cells

    NARCIS (Netherlands)

    Gupta, D.K.; Barink, M.; Galagan, Y.; Langelaar, M.

    2016-01-01

    Free-form solar cells expand solar power beyond traditional rectangular geometries. With the flexibility of being installed on objects of daily use, they allow making better use of available space and are expected to bring in new possibilities of generating solar power in the coming future. In

  15. A numerical method for the design of free-form reflectors for lighting applications

    NARCIS (Netherlands)

    Prins, C.R.; Thije Boonkkamp, ten J.H.M.; Roosmalen, van J.; IJzerman, W.L.; Tukker, T.W.

    2013-01-01

    In this article we present a method for the design of fully free-form reflectors for illumination systems. We derive an elliptic partial differential equation of the Monge-Ampère type for the surface of a reflector that converts an arbitrary parallel beam of light into a desired intensity output

  16. Determining the VLF/ULF source height using phase measurements

    Science.gov (United States)

    Ryabov, A.; Kotik, D. S.

    2012-12-01

    Generation of ULF/VLF waves in the ionosphere using powerful RF facilities has been studied for the last 40 years, both theoretically and experimentally. During this time, it was proposed several mechanisms for explaining the experimental results: modulation of ionospheric currents based on thermal nonlinearity, ponderomotive mechanisms for generation both VLF and ULF signals, cubic nonlinearity, etc. According mentioned above mechanisms the VLF/ULF signal source could be located in the lower or upper ionosphere. The group velocity of signal propagation in the ionosphere is significantly smaller than speed of light. As a result the appreciable time delay of the received signals will occur at the earth surface. This time delay could be determine by measuring the phase difference between received and reference signals, which are GPS synchronized. The experiment on determining the time delay of ULF signal propagation from the ionospheric source was carried out at SURA facility in 2012 and the results are presented in this paper. The comparison with numerical simulation of the time delay using the adjusted IRI model and ionosonde data shows well agreement with the experimental observations. The work was supported by RFBR grant 11-02-00419-a and RF Ministry of education and science by state contract 16.518.11.7066.

  17. Pulsed Source Measurements on a Uranium-Water Subcritical Assembly

    International Nuclear Information System (INIS)

    Gibson, I.H.; Walker, J.

    1964-01-01

    An unreflected assembly of natural uranium and light water has been used in conjunction with a pulsed source of neutrons for decay-time measurements at different bucklings. Four different lattice pitches over the range 3.94 cm to 5.08 cm were obtained by using different pairs of accurately machined lattice plates and in each case the uranium was in the form of bars 109.8 cm long and 3.0 cm diameter. The fuel- was mounted horizontally and loadings up to approximately 6 t were involved. Spatial harmonics were eliminated or selected by appropriate placing of a small scintillation detector. Experimental results showing the dependence of decay constant on buckling are presented and compared with theoretical values. (author) [fr

  18. Measuring The Variability Of Gamma-Ray Sources With AGILE

    International Nuclear Information System (INIS)

    Chen, Andrew W.; Vercellone, Stefano; Pellizzoni, Alberto; Tavani, Marco

    2005-01-01

    Variability in the gamma-ray flux above 100 MeV at various time scales is one of the primary characteristics of the sources detected by EGRET, both allowing the identification of individual sources and constraining the unidentified source classes. We present a detailed simulation of the capacity of AGILE to characterize the variability of gamma-ray sources, discussing the implications for source population studies

  19. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: an electronic brachytherapy source.

    Science.gov (United States)

    Rivard, Mark J; Davis, Stephen D; DeWerd, Larry A; Rusch, Thomas W; Axelrod, Steve

    2006-11-01

    A new x-ray source, the model S700 Axxent X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, S700 Source exhibited depth dose behavior similar to low-energy photon-emitting low dose rate sources 125I and l03Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages.

  20. MEASURING THE SOURCES OF THE INTERGALACTIC IONIZING FLUX

    International Nuclear Information System (INIS)

    Cowie, L. L.; Barger, A. J.; Trouille, L.

    2009-01-01

    We use a wide-field (0.9 deg 2 ) X-ray sample with optical and Galaxy Evolution Explorer (GALEX) ultraviolet observations to measure the contribution of active galactic nuclei (AGNs) to the ionizing flux as a function of redshift. Our analysis shows that the AGN contribution to the metagalactic ionizing background peaks at around z = 2. The measured values of the ionizing background from the AGNs are lower than previous estimates and confirm that ionization from AGNs is insufficient to maintain the observed ionization of the intergalactic medium (IGM) at z > 3. We show that only X-ray sources with broad lines in their optical spectra have detectable ionizing flux and that the ionizing flux seen in an AGN is not correlated with its X-ray color. We also use the GALEX observations of the GOODS-N region to place a 2σ upper limit of 0.008 on the average ionization fraction f ν (700 A)/f ν (1500 A) for 626 UV selected galaxies in the redshift range z = 0.9-1.4. We then use this limit to estimate an upper bound to the galaxy contribution in the redshift range z = 0-5. If the z ∼ 1.15 ionization fraction is appropriate for higher-redshift galaxies, then contributions from the galaxy population are also too low to account for the IGM ionization at the highest redshifts (z > 4).

  1. Solid Freeform and Additive Fabrication - 2000: Symposium Held in San Francisco, California on April 23-26, 2000

    National Research Council Canada - National Science Library

    Danforth, Stephen

    2000-01-01

    Solid freeform (SFF) and additive fabrication processes are defining a revolutionary new approach for materials manufacturing that is leading to a capability for producing parts quicker, cheaper and with more...

  2. Back-trajectory modeling of high time-resolution air measurement data to separate nearby sources

    Science.gov (United States)

    Strategies to isolate air pollution contributions from sources is of interest as voluntary or regulatory measures are undertaken to reduce air pollution. When different sources are located in close proximity to one another and have similar emissions, separating source emissions ...

  3. Sources of Variation in Sweat Chloride Measurements in Cystic Fibrosis

    Science.gov (United States)

    Blackman, Scott M.; Raraigh, Karen S.; Corvol, Harriet; Rommens, Johanna M.; Pace, Rhonda G.; Boelle, Pierre-Yves; McGready, John; Sosnay, Patrick R.; Strug, Lisa J.; Knowles, Michael R.; Cutting, Garry R.

    2016-01-01

    Rationale: Expanding the use of cystic fibrosis transmembrane conductance regulator (CFTR) potentiators and correctors for the treatment of cystic fibrosis (CF) requires precise and accurate biomarkers. Sweat chloride concentration provides an in vivo assessment of CFTR function, but it is unknown the degree to which CFTR mutations account for sweat chloride variation. Objectives: To estimate potential sources of variation for sweat chloride measurements, including demographic factors, testing variability, recording biases, and CFTR genotype itself. Methods: A total of 2,639 sweat chloride measurements were obtained in 1,761 twins/siblings from the CF Twin-Sibling Study, French CF Modifier Gene Study, and Canadian Consortium for Genetic Studies. Variance component estimation was performed by nested mixed modeling. Measurements and Main Results: Across the tested CF population as a whole, CFTR gene mutations were found to be the primary determinant of sweat chloride variability (56.1% of variation) with contributions from variation over time (e.g., factors related to testing on different days; 13.8%), environmental factors (e.g., climate, family diet; 13.5%), other residual factors (e.g., test variability; 9.9%), and unique individual factors (e.g., modifier genes, unique exposures; 6.8%) (likelihood ratio test, P < 0.001). Twin analysis suggested that modifier genes did not play a significant role because the heritability estimate was negligible (H2 = 0; 95% confidence interval, 0.0–0.35). For an individual with CF, variation in sweat chloride was primarily caused by variation over time (58.1%) with the remainder attributable to residual/random factors (41.9%). Conclusions: Variation in the CFTR gene is the predominant cause of sweat chloride variation; most of the non-CFTR variation is caused by testing variability and unique environmental factors. If test precision and accuracy can be improved, sweat chloride measurement could be a valuable biomarker

  4. Generalised perturbation theory and source of information through chemical measurements

    International Nuclear Information System (INIS)

    Lelek, V.; Marek, T.

    2001-01-01

    It is important to make all analyses and collect all information from the work of the new facility (which the transmutation demonstration unit will surely be) to be sure that the operation corresponds to the forecast or to correct the equations of the facility. The behaviour of the molten salt reactor and in particular the system of measurement are very different from that of the solid fuel reactor. Key information from the long time kinetics could be the nearly on line knowledge of the fuel composition. In this work it is shown how to include it into the control and use such data for the correction of neutron cross-sections for the high actinides or other characteristics. Also the problem of safety - change of the boundary problem to the initial problem - is mentioned. The problem is transformed into the generalised perturbation theory in which the adjoint function is obtained through the solution of the equations with right hand side having the form of source. Such an approach should be a theoretical base for the calculation of the sensitivity coefficients. (authors)

  5. Optimal Measurement Conditions for Spatiotemporal EEG/MEG Source Analysis.

    Science.gov (United States)

    Huizenga, Hilde M.; Heslenfeld, Dirk J.; Molenaar, Peter C. M.

    2002-01-01

    Developed a method to determine the required number and position of sensors for human brain electromagnetic source analysis. Studied the method through a simulation study and an empirical study on visual evoked potentials in one adult male. Results indicate the method is fast and reliable and improves source precision. (SLD)

  6. Measurement of the equivalent fundamental-mode source strength

    International Nuclear Information System (INIS)

    Spriggs, G.D.; Busch, R.D.

    1997-01-01

    The steady-state multiplication, M, of a subcritical system that is in equilibrium with an external/intrinsic source is defined as the total neutron-production rate divided by the external/ intrinsic neutron source rate, S. The total neutron-production rate, in this context, is the sum of the fission-production rate plus the source rate. Because the system is in equilibrium, the total neutron-production rate is identically equal to the loss rate from the system due to absorption plus leakage. If the source S is distributed identically to the fission source distribution (i.e., angle, energy, and space), then M will be related to the effective multiplication factor of the system, k eff , as M = 1/1-k eff

  7. Grain Refinement of Freeform Fabricated Ti-6Al-4V Alloy Using Beam/Arc Modulation

    Science.gov (United States)

    Mitzner, Scott; Liu, Stephen; Domack, Marcia S.; Hafley, Robert A.

    2012-01-01

    Grain refinement can significantly improve the mechanical properties of freeform-fabricated Ti-6Al-4V alloy, promoting increased strength and enhanced isotropy compared with coarser grained material. Large beta-grains can lead to a segregated microstructure, in regard to both alpha-phase morphology and alpha-lath orientation. Beam modulation, which has been used in conventional fusion welding to promote grain refinement, is explored in this study for use in additive manufacturing processes including electron beam freeform fabrication (EBF(sup 3)) and gas-tungsten arc (GTA) deposition to alter solidification behavior and produce a refined microstructure. The dynamic molten pool size induced by beam modulation causes rapid heat flow variance and results in a more competitive grain growth environment, reducing grain size. Consequently, improved isotropy and strength can be achieved with relatively small adjustments to deposition parameters.

  8. Antimalarial measures - type, sources of advice and compliance ...

    African Journals Online (AJOL)

    1994-06-01

    Jun 1, 1994 ... pharmacies as well as actual behaviour in this regard and sources of advice accessed ... pharmacies and 53 'care providers' (members of travel parties). Doctors ... TPS Drug Information Services, Johannesburg. L Baker, DIP.

  9. National Management Measures to Control Nonpoint Source Pollution from Forestry

    Science.gov (United States)

    This report helps forest owners protect lakes and streams from polluted runoff that can result from forestry activities. The report will also help states to implement their nonpoint source control programs.

  10. Automatic fitting of conical envelopes to free-form surfaces for flank CNC machining

    OpenAIRE

    Bo P.; Bartoň M.; Pottmann H.

    2017-01-01

    We propose a new algorithm to detect patches of free-form surfaces that can be well approximated by envelopes of a rotational cone under a rigid body motion. These conical envelopes are a preferable choice from the manufacturing point of view as they are, by-definition, manufacturable by computer numerically controlled (CNC) machining using the efficient flank (peripheral) method with standard conical tools. Our geometric approach exploits multi-valued vector fields that consist of vectors in...

  11. Advances in Design and Fabrication of Free-Form Reciprocal Structures

    DEFF Research Database (Denmark)

    Parigi, Dario

    2016-01-01

    The paper presents the advances in design and fabrication of free-form Reciprocal Structures, and their application a during a one-week long workshop with the students of the 1st semester of the Master of Science in Architecture and Design, fall 2015, at Aalborg University. Two new factors were...... introduced and tested: a new version of the software Reciprocalizer, and an evolution of the Reciprocalizer Robot. The workshop didactic framework Performance Aided/Assisted Design (PAD) is presented....

  12. 3D Printing PDMS Elastomer in a Hydrophilic Support Bath via Freeform Reversible Embedding

    OpenAIRE

    Hinton, Thomas J.; Hudson, Andrew; Pusch, Kira; Lee, Andrew; Feinberg, Adam W.

    2016-01-01

    Polydimethylsiloxane (PDMS) elastomer is used in a wide range of biomaterial applications including microfluidics, cell culture substrates, flexible electronics, and medical devices. However, it has proved challenging to 3D print PDMS in complex structures due to its low elastic modulus and need for support during the printing process. Here we demonstrate the 3D printing of hydrophobic PDMS prepolymer resins within a hydrophilic Carbopol gel support via freeform reversible embedding (FRE). In...

  13. Why are freeform telescopes less alignment sensitive than a traditional unobscured TMA?

    Science.gov (United States)

    Thompson, Kevin P.; Schiesser, Eric; Rolland, Jannick P.

    2015-10-01

    As freeform optical systems emerge as interesting and innovative solutions for imaging in 3D packages there is an assumption they are going to be more sensitive particularly at assembly. While it is true that the clocking of the component becomes a relatively weak new tolerance, for the most effective new class of freeform systems the alignment sensitivity is actually lower in most cases than for a comparable traditional unobscured three mirror anastigmatic (TMA) telescope. Traditional unobscured TMA telescopes, whose designs emerged in the mid-70s and which begin to appear as hardware in the literature in the early 90s, are based on using increasingly offset apertures with otherwise coaxial rotationally symmetric mirrors. The mirrors (typically 3 to correct spherical, coma, and astigmatism) have evolved to contain more high order terms as the designs are pushed to more compact and wider field packages - the NIRCAM camera for the JWST is an excellent example of this [1]. As the higher order terms are added, the mirrors become increasingly sensitive to decenters and tilts. An emerging class of freeform telescopes that provide wider field of view and/or faster f/numbers than the traditional TMA are based on a strategy where the surface shape remains a low order Zernike-type surface even in compact, unobscured packages. This optical design strategy results in an optical form that is not only higher performance but simultaneously less sensitive to alignment.

  14. Isogeometric analysis of free-form Timoshenko curved beams including the nonlinear effects of large deformations

    Science.gov (United States)

    Hosseini, Seyed Farhad; Hashemian, Ali; Moetakef-Imani, Behnam; Hadidimoud, Saied

    2018-03-01

    In the present paper, the isogeometric analysis (IGA) of free-form planar curved beams is formulated based on the nonlinear Timoshenko beam theory to investigate the large deformation of beams with variable curvature. Based on the isoparametric concept, the shape functions of the field variables (displacement and rotation) in a finite element analysis are considered to be the same as the non-uniform rational basis spline (NURBS) basis functions defining the geometry. The validity of the presented formulation is tested in five case studies covering a wide range of engineering curved structures including from straight and constant curvature to variable curvature beams. The nonlinear deformation results obtained by the presented method are compared to well-established benchmark examples and also compared to the results of linear and nonlinear finite element analyses. As the nonlinear load-deflection behavior of Timoshenko beams is the main topic of this article, the results strongly show the applicability of the IGA method to the large deformation analysis of free-form curved beams. Finally, it is interesting to notice that, until very recently, the large deformations analysis of free-form Timoshenko curved beams has not been considered in IGA by researchers.

  15. Neutron source strength determination for on-line reactivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, J.E.; Sluijs, A.R. van der

    1988-01-01

    A method is described to determine the effective neutron source strength in a nuclear reactor, which must be known when calculating the time-varying reactivity from inverse reactor kinetics for a reactor at low power. When for an initially subcritical reactor the reactivity is changed and kept constant after the change, the effective source strength can be determined from a linear regression of reactor power to a function proportional to the emission rate of delayed neutrons, which can be calculated from the reactor power history. In view of the relatively strong noise present in the reactor power signal at low power, a grouping method for the regression is preferred over the least-squares method. Experiments with a reactor simulator with known source strength showed good agreement. Application to actual reactor signals gave consistent and satisfactory results.

  16. Protocol of source shielding maintenance in a level measurement systems

    International Nuclear Information System (INIS)

    Gonzales, E.; Figueroa, J.

    1996-01-01

    Maintenance labor of the source shielding and locking system is not performed in many Venezuelan enterprises that employ radioactive level gauge in large container. The lack of maintenance and the ambient long lasting action have produced impairment of many devices and their given parts rise to economical and radiological protection problems. In order to help to solve the mentioned problems, principally to reduce the unjustified dose to workers, the IVIC Health Physics Service worked out a protocol to perform, in a safety way, the maintenance of source shielding and its locking system. This protocol is presented in this paper. (authors)

  17. Robust Spatial Approximation of Laser Scanner Point Clouds by Means of Free-form Curve Approaches in Deformation Analysis

    Science.gov (United States)

    Bureick, Johannes; Alkhatib, Hamza; Neumann, Ingo

    2016-03-01

    In many geodetic engineering applications it is necessary to solve the problem of describing a measured data point cloud, measured, e. g. by laser scanner, by means of free-form curves or surfaces, e. g., with B-Splines as basis functions. The state of the art approaches to determine B-Splines yields results which are seriously manipulated by the occurrence of data gaps and outliers. Optimal and robust B-Spline fitting depend, however, on optimal selection of the knot vector. Hence we combine in our approach Monte-Carlo methods and the location and curvature of the measured data in order to determine the knot vector of the B-Spline in such a way that no oscillating effects at the edges of data gaps occur. We introduce an optimized approach based on computed weights by means of resampling techniques. In order to minimize the effect of outliers, we apply robust M-estimators for the estimation of control points. The above mentioned approach will be applied to a multi-sensor system based on kinematic terrestrial laserscanning in the field of rail track inspection.

  18. The design of an ultra-thin and multiple channels optical receiving antenna system with freeform lenses

    Science.gov (United States)

    Zhang, Lingyun; Cheng, Dewen; Hu, Yuan; Song, Weitao; Wang, Yongtian

    2014-11-01

    Visible Light Communications (VLC) has become an emerging area of research since it can provide higher data transmission speed and wider bandwidth. The white LEDs are very important components of the VLC system, because it has the advantages of higher brightness, lower power consumption, and a longer lifetime. More importantly, their intensity and color are modulatable. Besides the light source, the optical antenna system also plays a very important role in the VLC system since it determines the optical gain, effective working area and transmission rate of the VLC system. In this paper, we propose to design an ultra-thin and multiple channels optical antenna system by tiling multiple off-axis lenses, each of which consists of two reflective and two refractive freeform surfaces. The tiling of multiple systems and detectors but with different band filters makes it possible to design a wavelength division multiplexing VLC system to highly improve the system capacity. The field of view of the designed antenna system is 30°, the entrance pupil diameter is 1.5mm, and the thickness of the system is under 4mm. The design methods are presented and the results are discussed in the last section of this paper. Besides the optical gain is analyzed and calculated. The antenna system can be tiled up to four channels but without the increase of thickness.

  19. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: An electronic brachytherapy source

    International Nuclear Information System (INIS)

    Rivard, Mark J.; Davis, Stephen D.; DeWerd, Larry A.; Rusch, Thomas W.; Axelrod, Steve

    2006-01-01

    A new x-ray source, the model S700 Axxent trade mark sign X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, P (5) were 0.20, 0.24, and 0.29 for the 40, 45, and 50 kV voltage settings, respectively. For 1 125 I and 103 Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages

  20. Measurement of radon in Spanish houses: characterization of its sources

    International Nuclear Information System (INIS)

    1998-01-01

    The determination of radon concentrations in-house are analyzed by different universities. The programs of Cantabria, Valencia, Barcelona and La Laguna Universities are presented. These programs study the environmental impact of radon in Barcelona and Madrid and characterize the radon sources

  1. Stable source reconstruction from a finite number of measurements in the multi-frequency inverse source problem

    DEFF Research Database (Denmark)

    Karamehmedovic, Mirza; Kirkeby, Adrian; Knudsen, Kim

    2018-01-01

    setting: From measurements made at a finite set of frequencies we uniquely determine and reconstruct sources in a subspace spanned by finitely many Fourier-Bessel functions. Further, we obtain a constructive criterion for identifying a minimal set of measurement frequencies sufficient for reconstruction......, and under an additional, mild assumption, the reconstruction method is shown to be stable." Our analysis is based on a singular value decomposition of the source-to-measurement forward operators and the distribution of positive zeros of the Bessel functions of the first kind. The reconstruction method...

  2. Identifying and correcting epigenetics measurements for systematic sources of variation.

    NARCIS (Netherlands)

    Perrier, Flavie; Novoloaca, Alexei; Ambatipudi, Srikant; Baglietto, Laura; Ghantous, Akram; Perduca, Vittorio; Barrdahl, Myrto; Harlid, Sophia; Ong, Ken K; Cardona, Alexia; Polidoro, Silvia; Nøst, Therese Haugdahl; Overvad, Kim; Omichessan, Hanane; Dollé, Martijn; Bamia, Christina; Huerta, José Marìa; Vineis, Paolo; Herceg, Zdenko; Romieu, Isabelle; Ferrari, Pietro

    2018-01-01

    Methylation measures quantified by microarray techniques can be affected by systematic variation due to the technical processing of samples, which may compromise the accuracy of the measurement process and contribute to bias the estimate of the association under investigation. The quantification of

  3. Orbital electron capture measurements with an internal-source spectrometer

    International Nuclear Information System (INIS)

    Gerner, C.P.

    1978-01-01

    Electron-capture measurements have been performed on 131 Ba and on 106 Agsup(m). For 131 Ba the L/K-and M/L-capture rations of the allowed decay have been measured to the 1048 keV level in 131 Cs. The Qsub(EC) value, the exchange- and overlap-correction factors Xsup(L/K) and Xsup(M/L) and the reduced capture ratios have been determined. For 106 Agsup(m) the L/K-capture ratio of the allowed decay has been measured to the 2757 keV level in 106 Pd. The Q value, the exchange- and overlap-correction factor Xsup(L/K) and the reduced L/K- capture ratio have been derived. The measurements indicate that agreement between experimentally determined capture ratios and exchange-corrected theoretical predictions is fairly good, both for allowed and for first-forbidden non-unique transitions. (Auth./C.F.)

  4. Gamma-ray measurements at the WNR white neutron source

    International Nuclear Information System (INIS)

    Nelson, R.O.; Wender, S.A.; Mayo, D.R.

    1994-01-01

    Photon production data have been acquired in the incident neutron energy range, 1 n γ 56 Fe, and 207,208 Pb. These data are useful both for testing nuclear reaction models at intermediate energies and for numerous applied purposes. BGO detectors do not have the good energy resolution of Ge detectors, but have much greater detection efficiency for gamma rays with energies greater than a few MeV. We have used an array of 5 BGO detectors to measure cross sections and angular distributions for photon production from C and N. A large, well-shielded BGO detector has been used to measure fast neutron capture in the giant resonance region with a maximum gamma-ray energy of 52 MeV. We present results of our study of the isovector giant quadrupole resonance in 41 Ca via these capture measurements. Recent measurements of inclusive photon spectra from our neutron proton Bremsstrahlung experiment have been made using a gamma-ray telescope to detect gamma-rays in the energy range, 40 γ < 300 MeV. This detector is briefly described. The advantages and disadvantages of these detector systems are discussed using examples from our measurements. The status of current measurements is presented

  5. 76 FR 53897 - EPA Seeking Input Materials Measurement; Municipal Solid Waste (MSW), Recycling, and Source...

    Science.gov (United States)

    2011-08-30

    ... Measurement; Municipal Solid Waste (MSW), Recycling, and Source Reduction Measurement in the U.S. AGENCY... Subjects Environmental protection, municipal solid waste (MSW) characterization, MSW management, recycling, measurement, data, data collection, construction and demolition (C&D) recycling, source reduction, life cycle...

  6. Evaluating measurements of carbon dioxide emissions using a precision source--A natural gas burner.

    Science.gov (United States)

    Bryant, Rodney; Bundy, Matthew; Zong, Ruowen

    2015-07-01

    A natural gas burner has been used as a precise and accurate source for generating large quantities of carbon dioxide (CO2) to evaluate emissions measurements at near-industrial scale. Two methods for determining carbon dioxide emissions from stationary sources are considered here: predicting emissions based on fuel consumption measurements-predicted emissions measurements, and direct measurement of emissions quantities in the flue gas-direct emissions measurements. Uncertainty for the predicted emissions measurement was estimated at less than 1%. Uncertainty estimates for the direct emissions measurement of carbon dioxide were on the order of ±4%. The relative difference between the direct emissions measurements and the predicted emissions measurements was within the range of the measurement uncertainty, therefore demonstrating good agreement. The study demonstrates how independent methods are used to validate source emissions measurements, while also demonstrating how a fire research facility can be used as a precision test-bed to evaluate and improve carbon dioxide emissions measurements from stationary sources. Fossil-fuel-consuming stationary sources such as electric power plants and industrial facilities account for more than half of the CO2 emissions in the United States. Therefore, accurate emissions measurements from these sources are critical for evaluating efforts to reduce greenhouse gas emissions. This study demonstrates how a surrogate for a stationary source, a fire research facility, can be used to evaluate the accuracy of measurements of CO2 emissions.

  7. Free-form Flexible Lithium-Ion Microbattery

    KAUST Repository

    Kutbee, Arwa T.; Ghoneim, Mohamed T.; Ahmed, Sally; Hussain, Muhammad Mustafa

    2016-01-01

    Wearable electronics need miniaturized, safe and flexible power sources. Lithium ion battery is a strong candidate as high performance flexible battery. The development of flexible materials for battery electrodes suffers from the limited material

  8. Measures to remove impediments to better utilization. Renewable energy sources

    International Nuclear Information System (INIS)

    Diekmann, J.; Eichelbroenner, M.; Langniss, O.

    1997-01-01

    The utilization of renewable energy sources meets with a number of obstacles created in particular by economic framework conditions, regulatory provisions, lengthy administrative procedures, insufficient information, and to some part also to the reluctance of bankers and utilities. This is why an action programme was put underway by the Forum fuer Zukunftsenergien, together with the Berlin-based DIW (German economic research institute) and the Stuttgart-based DLR (German aerospace research institute), financed from public funds of the Federal Ministry of Economics. Under this programme, almost 900 operators of systems for electricity generation from wind power, hydropower, biomass, ambient heat, solar thermal energy and by photovoltaic conversion have been interviewed. Based on the information obtained, the article reveals the existing impediments and proposed action for overcoming the obstacles. (orig.) [de

  9. Measurements on the source properties of a hollow cathode

    NARCIS (Netherlands)

    Vogels, J.M.M.J.; Konings, L.U.E.; Koelman, J.M.V.A.; Schram, D.C.; Bötticher, W.; Wenk, H.; Schulz-Gulde, E.

    1983-01-01

    The ion production rate of a hollow cathode in a magnetized arc has been measured. At low magnetic fields supersonic ion drifts have been observed. The ionized fraction of the gas flow decreases with increasing flow and the ion flux saturates at high flow rates

  10. Use of radioactive sources in measuring characteristics of snowpacks

    Science.gov (United States)

    Henry W. Anderson; Philip M. McDonald; Lloyd W. Gay

    1963-01-01

    Use of radioactive probes inserted in mountain snowpacks may make possible more accurate appraisal and prediction of snowmelt water. Commercially available gamma and neutron probes were tested for their ability to measure snow density, ice lenses, and the thermal quality of individual layers in the snowpack.

  11. A review of international sources for road safety measures assessment.

    NARCIS (Netherlands)

    Yannis, G. Weijermars, W. & Kauppila, J.

    2012-01-01

    The efficiency assessment of road safety measures is considered to be an extremely useful tool in decision making; in particular, cost-benefit and cost-effectiveness analyses are carried out in several countries, in a more or less systematic way. The objective of this paper is to present findings

  12. Portable waveguide display system with a large field of view by integrating freeform elements and volume holograms.

    Science.gov (United States)

    Han, Jian; Liu, Juan; Yao, Xincheng; Wang, Yongtian

    2015-02-09

    A compact waveguide display system integrating freeform elements and volume holograms is presented here for the first time. The use of freeform elements can broaden the field of view, which limits the applications of a holographic waveguide. An optimized system can achieve a diagonal field of view of 45° when the thickness of the waveguide planar is 3mm. Freeform-elements in-coupler and the volume holograms out-coupler were designed in detail in our study, and the influence of grating configurations on diffraction efficiency was analyzed thoroughly. The off-axis aberrations were well compensated by the in-coupler and the diffraction efficiency of the optimized waveguide display system could reach 87.57%. With integrated design, stability and reliability of this monochromatic display system were achieved and the alignment of the system was easily controlled by the record of the volume holograms, which makes mass production possible.

  13. Design of an off-axis visual display based on a free-form projection screen to realize stereo vision

    Science.gov (United States)

    Zhao, Yuanming; Cui, Qingfeng; Piao, Mingxu; Zhao, Lidong

    2017-10-01

    A free-form projection screen is designed for an off-axis visual display, which shows great potential in applications such as flight training for providing both accommodation and convergence cues for pilots. The method based on point cloud is proposed for the design of the free-form surface, and the design of the point cloud is controlled by a program written in the macro-language. In the visual display based on the free-form projection screen, when the error of the screen along Z-axis is 1 mm, the error of visual distance at each filed is less than 1%. And the resolution of the design for full field is better than 1‧, which meet the requirement of resolution for human eyes.

  14. Active control of residual tool marks for freeform optics functionalization by novel biaxial servo assisted fly cutting.

    Science.gov (United States)

    Zhu, Zhiwei; To, Suet; Zhang, Shaojian

    2015-09-01

    The inherent residual tool marks (RTM) with particular patterns highly affect optical functions of the generated freeform optics in fast tool servo or slow tool servo (FTS/STS) diamond turning. In the present study, a novel biaxial servo assisted fly cutting (BSFC) method is developed for flexible control of the RTM to be a functional micro/nanotexture in freeform optics generation, which is generally hard to achieve in FTS/STS diamond turning. In the BSFC system, biaxial servo motions along the z-axis and side-feeding directions are mainly adopted for primary surface generation and RTM control, respectively. Active control of the RTM from the two aspects, namely, undesired effect elimination or effective functionalization, are experimentally demonstrated by fabricating a typical F-theta freeform surface with scattering homogenization and two functional microstructures with imposition of secondary phase gratings integrating both reflective and diffractive functions.

  15. Sources of errors in the measurements of underwater profiling radiometer

    Digital Repository Service at National Institute of Oceanography (India)

    Silveira, N.; Suresh, T.; Talaulikar, M.; Desa, E.; Matondkar, S.G.P.; Lotlikar, A.

    to meet the stringent quality requirements of marine optical data for satellite ocean color sensor validation, development of algorithms and other related applications, it is very essential to take great care while measuring these parameters. There are two... of the pelican hook. The radiometer dives vertically and the cable is paid out with less tension, keeping in tandem with the descent of the radiometer while taking care to release only the required amount of cable. The operation of the release mechanism lever...

  16. A Comparative Evaluation of 3 Different Free-Form Deformable Image Registration and Contour Propagation Methods for Head and Neck MRI: The Case of Parotid Changes During Radiotherapy.

    Science.gov (United States)

    Broggi, Sara; Scalco, Elisa; Belli, Maria Luisa; Logghe, Gerlinde; Verellen, Dirk; Moriconi, Stefano; Chiara, Anna; Palmisano, Anna; Mellone, Renata; Fiorino, Claudio; Rizzo, Giovanna

    2017-06-01

    To validate and compare the deformable image registration and parotid contour propagation process for head and neck magnetic resonance imaging in patients treated with radiotherapy using 3 different approaches-the commercial MIM, the open-source Elastix software, and an optimized version of it. Twelve patients with head and neck cancer previously treated with radiotherapy were considered. Deformable image registration and parotid contour propagation were evaluated by considering the magnetic resonance images acquired before and after the end of the treatment. Deformable image registration, based on free-form deformation method, and contour propagation available on MIM were compared to Elastix. Two different contour propagation approaches were implemented for Elastix software, a conventional one (DIR_Trx) and an optimized homemade version, based on mesh deformation (DIR_Mesh). The accuracy of these 3 approaches was estimated by comparing propagated to manual contours in terms of average symmetric distance, maximum symmetric distance, Dice similarity coefficient, sensitivity, and inclusiveness. A good agreement was generally found between the manual contours and the propagated ones, without differences among the 3 methods; in few critical cases with complex deformations, DIR_Mesh proved to be more accurate, having the lowest values of average symmetric distance and maximum symmetric distance and the highest value of Dice similarity coefficient, although nonsignificant. The average propagation errors with respect to the reference contours are lower than the voxel diagonal (2 mm), and Dice similarity coefficient is around 0.8 for all 3 methods. The 3 free-form deformation approaches were not significantly different in terms of deformable image registration accuracy and can be safely adopted for the registration and parotid contour propagation during radiotherapy on magnetic resonance imaging. More optimized approaches (as DIR_Mesh) could be preferable for critical

  17. Towards efficient 5-axis flank CNC machining of free-form surfaces via fitting envelopes of surfaces of revolution

    OpenAIRE

    Bo P.; Bartoň M.; Plakhotnik D.; Pottmann H.

    2016-01-01

    We introduce a new method that approximates free-form surfaces by envelopes of one-parameter motions of surfaces of revolution. In the context of 5-axis computer numerically controlled (CNC) machining, we propose a flank machining methodology which is a preferable scallop-free scenario when the milling tool and the machined free-form surface meet tangentially along a smooth curve. We seek both an optimal shape of the milling tool as well as its optimal path in 3D space and propose an optimiza...

  18. Magnetic measurements of the injector synchrotron magnets for the Advanced Photon Source

    International Nuclear Information System (INIS)

    Kim, S.H.; Carnegie, D.W.; Doose, C.L.; Hogrefe, R.; Kim, K.; Merl, R.; Turner, L.R.

    1993-01-01

    The magnetic measurement data of the dipole, quadrupole, and sextupole magnets for the Advanced Photon Source injector synchrotron are summarized. Magnet design and magnetic measurements of the field strength, field shape, and multipole coefficients are described

  19. Magnetic measurements of the injector synchrotron magnets for the advanced photon source

    Science.gov (United States)

    Kim, S. H.; Carnegie, D. W.; Doose, C. L.; Hogrefe, R.; Kim, K.; Merl, R.; Turner, L. R.

    1994-07-01

    The magnetic measurement data of the dipole, quadrupole, and sextupole magnets for the Advanced Photon Source injector synchrotron are summarized. Magnet design and magnetic measurements of the field strength, field shape, and multipole coefficients are described.

  20. Determination of Free-Form and Peptide Bound Pyrraline in the Commercial Drinks Enriched with Different Protein Hydrolysates

    Directory of Open Access Journals (Sweden)

    Zhili Liang

    2016-07-01

    Full Text Available Pyrraline, a causative factor for the recent epidemics of diabetes and cardiovascular disease, is also employed as an indicator to evaluate heat damage and formation of advanced glycation end-products (AGEs in foods. Peptide-enriched drinks (PEDs are broadly consumed worldwide due to rapid rate of absorption and perceived health effects. It can be hypothesized that PED is an important source of pyrraline, especially peptide bound pyrraline (Pep-Pyr. In this study we determined free-form pyrraline (Free-Pyr and Pep-Pyr in drinks enriched with whey protein hydrolysate (WPH, soy protein hydrolysate (SPH and collagen protein hydrolysate (CPH. A detection method was developed using ultrahigh-performance liquid chromatography with UV-visible detector coupled with tandem mass spectrometry after solid-phase extraction (SPE. The SPE led to excellent recovery rates ranging between 93.2% and 98.5% and a high reproducibility with relative standard deviations (RSD of <5%. The limits of detection and quantification obtained were 30.4 and 70.3 ng/mL, respectively. Pep-Pyr was identified as the most abundant form (above 96 percent of total pyrraline, whereas Free-Pyr was present in a small proportion (less than four percent of total pyrraline. The results indicate that PED is an important extrinsic source of pyrraline, especially Pep-Pyr. As compared with CPH- and SPH-enriched drinks, WPH-enriched drinks contained high content of Pep-Pyr. The Pep-Pyr content is associated with the distribution of peptide lengths and the amino acid compositions of protein in PEDs.

  1. Design of off-axial Gregory telescope design with freeform mirror corrector

    Science.gov (United States)

    Bazhanov, Yu.; Vlakhko, V.

    2017-08-01

    In this paper a well-known approach is used for calculation of off-axis three-mirror telescope. It includes usage of conic cross-sections properties, each of the sections forming a stigmatic image. To create a compact optical system, a flat mirror aberration corrector is introduced, which is at later stage transformed into a free-form surface in order to compensate field aberrations. Similarly, one can introduce such a corrector in finalized layout for its further optimization and getting a suitable form, including the conversion of multimirrors axial optical system into decentered one. As an example, off-axial Gregory telescope embodiment is used for infrared waveband region, due to the fact that, unlike the Cassegrain telescope, it provides a real exit pupil, and usage of the mirror corrector brings several advantages. Firstly, this feature may be used to include cold stop or adaptive mirror in the exit pupil, wherein corrector is introduced into a converging beam before the focus of the first mirror. Secondly, when placing corrector in the exit pupil of the optical system it is possible to eliminate high and low order aberrations of center point, which in turn improves optical system f-number, and minimize field aberrations. As another example, off-axial Ritchey-Chretien telescope embodiment is used as a good fit for visible region systems. Analysis and calculation results of optical systems with free-form correctors with surfaces, defined by Power polynomial series are presented in this paper. Advantages of different freeform surfaces usage depends on optical system layouts specifics.

  2. Measured Performance of a Low Temperature Air Source Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R. K. [Johnson Research LLC, Pueblo West, CO (United States)

    2013-09-01

    A 4-ton Low Temperature Heat Pump (LTHP) manufactured by Hallowell International was installed in a residence near New Haven, Connecticut and monitored over two winters of operation. After attending to some significant service issues, the heat pump operated as designed. This report should be considered a review of the dual compressor 'boosted heat pump' technology. The Low Temperature Heat Pumpsystem operates with four increasing levels of capacity (heat output) as the outdoor temperature drops. The system was shown to select capacity correctly, supplying the appropriate amount of heat to the house across the full range of outdoor temperatures. The system's Coefficient of Performance (Seasonal COP, or SCOP) over two entire winters was calculated, based on measured data, to be 3.29over the first winter and 2.68 over the second winter. A second seasonal efficiency calculation by a different method yielded a SCOP of 2.78 for the first winter and 2.83 for the second winter. This second seasonal efficiency calculation was determined by comparing measured heat pump energy use to the in situ energy use with resistance heat alone. This method is the ratio of the slopes of thedaily energy use load lines.

  3. Sources and performance criteria of uncertainty of reference measurement procedures.

    Science.gov (United States)

    Mosca, Andrea; Paleari, Renata

    2018-05-29

    This article wants to focus on the today available Reference Measurement Procedures (RMPs) for the determination of various analytes in Laboratory Medicine and the possible tools to evaluate their performance in the laboratories who are currently using them. A brief review on the RMPs has been performed by investigating the Joint Committee for Traceability in Laboratory Medicine (JCTLM) database. In order to evaluate their performances, we have checked the organization of three international ring trials, i.e. those regularly performed by the IFCC External Quality assessment scheme for Reference Laboratories in Laboratory Medicine (RELA), by the Center for Disease Control and Prevention (CDC) cholesterol network and by the IFCC Network for HbA 1c . Several RMPs are available through the JCTLM database, but the best way to collect information about the RMPs and their uncertainties is to look at the reference measurement service providers (RMS). This part of the database and the background on how to listed in the database is very helpful for the assessment of expanded uncertainty (MU) and performance in general of RMPs. Worldwide, 17 RMS are listed in the database, and for most of the measurands more than one RMS is able to run the relative RMPs, with similar expanded uncertainties. As an example, for a-amylase, 4 SP offer their services with MU between 1.6 and 3.3%. In other cases (such as total cholesterol, the U may span over a broader range, i.e. from 0.02 to 3.6%). With regard to the performance evaluation, the approach is often heterogenous, and it is difficult to compare the performance of laboratories running the same RMP for the same measurand if involved in more than one EQAS. The reference measurement services have been created to help laboratory professionals and manufacturers to implement the correct metrological traceability, and the JCTLM database is the only correct way to retrieve all the necessary important information to this end. Copyright © 2018

  4. Interactive Modeling of Architectural Freeform Structures - Combining Geometry with Fabrication and Statics

    KAUST Repository

    Jiang, Caigui

    2014-09-01

    This paper builds on recent progress in computing with geometric constraints, which is particularly relevant to architectural geometry. Not only do various kinds of meshes with additional properties (like planar faces, or with equilibrium forces in their edges) become available for interactive geometric modeling, but so do other arrangements of geometric primitives, like honeycomb structures. The latter constitute an important class of geometric objects, with relations to “Lobel” meshes, and to freeform polyhedral patterns. Such patterns are particularly interesting and pose research problems which go beyond what is known for meshes, e.g. with regard to their computing, their flexibility, and the assessment of their fairness.

  5. Alignment engineering in liquid crystalline elastomers: Free-form microstructures with multiple functionalities

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Hao; Cerretti, Giacomo; Wiersma, Diederik S., E-mail: camilla.parmeggiani@lens.unifi.it, E-mail: wiersma@lens.unifi.it [European Laboratory for Non Linear Spectroscopy (LENS), University of Florence, via Nello Carrara 1, 50019 Sesto Fiorentino (Italy); Wasylczyk, Piotr [European Laboratory for Non Linear Spectroscopy (LENS), University of Florence, via Nello Carrara 1, 50019 Sesto Fiorentino (Italy); Faculty of Physics, Institute of Experimental Physics, University of Warsaw, ul. Hoza 69, Warszawa 00-681 (Poland); Martella, Daniele [European Laboratory for Non Linear Spectroscopy (LENS), University of Florence, via Nello Carrara 1, 50019 Sesto Fiorentino (Italy); Dipartimento di Chimica “Ugo Schiff,” University of Florence, via della Lastruccia 3-13, 50019 Sesto Fiorentino (Italy); Parmeggiani, Camilla, E-mail: camilla.parmeggiani@lens.unifi.it, E-mail: wiersma@lens.unifi.it [European Laboratory for Non Linear Spectroscopy (LENS), University of Florence, via Nello Carrara 1, 50019 Sesto Fiorentino (Italy); CNR-INO, via Nello Carrara 1, 50019 Sesto Fiorentino (Italy)

    2015-03-16

    We report a method to fabricate polymer microstructures with local control over the molecular orientation. Alignment control is achieved on molecular level in a structure of arbitrary form that can be from 1 to 100 μm in size, by fixing the local boundary conditions with micro-grating patterns. The method makes use of two-photon polymerization (Direct Laser Writing) and is demonstrated specifically in liquid-crystalline elastomers. This concept allows for the realization of free-form polymeric structures with multiple functionalities which are not possible to realize with existing techniques and which can be locally controlled by light in the micrometer scale.

  6. 2π absolute measurement research for α-electroplating source covering ZnS(Ag)

    International Nuclear Information System (INIS)

    Zhu Tianxia

    1999-01-01

    2π absolute measurement can be completed after the quantitative deposit (5 +- 1) mg/cm 2 with ZnS(Ag) on surface of the alpha electroplating source. The measuring efficiency is 100%. This method is suitable for both of electroplating ordinary sample and electroplating standard (of reference) source

  7. Free-form Flexible Lithium-Ion Microbattery

    KAUST Repository

    Kutbee, Arwa T.

    2016-03-02

    Wearable electronics need miniaturized, safe and flexible power sources. Lithium ion battery is a strong candidate as high performance flexible battery. The development of flexible materials for battery electrodes suffers from the limited material choices. In this work, we present integration strategy to rationally design materials and processes to report flexible inorganic lithium-ion microbattery with no restrictions on the materials used. The battery shows an enhanced normalized capacity of 147 μAh/cm2 when bent.

  8. Freeform Lens Design for Scattering Data with General Radiant Fields

    Science.gov (United States)

    Gutiérrez, Cristian E.; Sabra, Ahmad

    2018-05-01

    We show the existence of a lens, when its lower face is given, such that it refracts radiation emanating from a planar source, with a given field of directions, into the far field that preserves a given distribution of energies. Conditions are shown under which the lens obtained is physically realizable. It is shown that the upper face of the lens satisfies a pde of Monge-Ampère type.

  9. Source term determination from subcritical multiplication measurements at Koral-1 reactor

    International Nuclear Information System (INIS)

    Blazquez, J.B.; Barrado, J.M.

    1978-01-01

    By using an AmBe neutron source two independent procedures have been settled for the zero-power experimental fast-reactor Coral-1 in order to measure the source term which appears in the point kinetical equations. In the first one, the source term is measured when the reactor is just critical with source by taking advantage of the wide range of the linear approach to critical for Coral-1. In the second one, the measurement is made in subcritical state by making use of the previous calibrated control rods. Several applications are also included such as the measurement of the detector dead time, the determinations of the reactivity of small samples and the shape of the neutron importance of the source. (author)

  10. An Integrated Reverse Engineering Approach for Accuracy Control of Free-Form Objects

    Directory of Open Access Journals (Sweden)

    Pathak Vimal Kumar

    2016-12-01

    Full Text Available Computer-aided tools help in shortening and eradicating numerous repetitive tasks that reduces the gap between digital model and actual product. Use of these tools assists in realizing free-form objects such as custom fit products as described by a stringent interaction with the human body. Development of such a model presents a challenging situation for reverse engineering (RE which is not analogous with the requirement for generating simple geometric models. Hence, an alternating way of producing more accurate three-dimensional models is proposed. For creating accurate 3D models, point clouds are processed through filtering, segmentation, mesh smoothing and surface generation. These processes help in converting the initial unorganized point data into a 3D digital model and simultaneously influence the quality of model. This study provides an optimum balance for the best accuracy obtainable with maximum allowable deviation to lessen computer handling and processing time. A realistic non trivial case study of free-form prosthetic socket is considered. The accuracy obtained for the developed model is acceptable for the use in medical applications and FEM analysis.

  11. Design of an ultra-thin near-eye display with geometrical waveguide and freeform optics.

    Science.gov (United States)

    Cheng, Dewen; Wang, Yongtian; Xu, Chen; Song, Weitao; Jin, Guofan

    2014-08-25

    Small thickness and light weight are two important requirements for a see-through near-eye display which are achieved in this paper by using two advanced technologies: geometrical waveguide and freeform optics. A major problem associated with the geometrical waveguide is the stray light which can severely degrade the display quality. The causes and solutions to this problem are thoroughly studied. A mathematical model of the waveguide is established and a non-sequential ray tracing algorithm is developed, which enable us to carefully examine the stray light of the planar waveguide and explore a global searching method to find an optimum design with the least amount of stray light. A projection optics using freeform surfaces on a wedge shaped prism is also designed. The near-eye display integrating the projection optics and the waveguide has a field of view of 28°, an exit pupil diameter of 9.6mm and an exit pupil distance of 20mm. In our final design, the proportion of the stray light energy over the image output energy of the waveguide is reduced to 2%, the modulation transfer function values across the entire field of the eyepiece are above 0.5 at 30 line pairs/mm (lps/mm). A proof-of-concept prototype of the proposed geometrical waveguide near-eye display is developed and demonstrated.

  12. Optimization of freeform surfaces using intelligent deformation techniques for LED applications

    Science.gov (United States)

    Isaac, Annie Shalom; Neumann, Cornelius

    2018-04-01

    For many years, optical designers have great interests in designing efficient optimization algorithms to bring significant improvement to their initial design. However, the optimization is limited due to a large number of parameters present in the Non-uniform Rationaly b-Spline Surfaces. This limitation was overcome by an indirect technique known as optimization using freeform deformation (FFD). In this approach, the optical surface is placed inside a cubical grid. The vertices of this grid are modified, which deforms the underlying optical surface during the optimization. One of the challenges in this technique is the selection of appropriate vertices of the cubical grid. This is because these vertices share no relationship with the optical performance. When irrelevant vertices are selected, the computational complexity increases. Moreover, the surfaces created by them are not always feasible to manufacture, which is the same problem faced in any optimization technique while creating freeform surfaces. Therefore, this research addresses these two important issues and provides feasible design techniques to solve them. Finally, the proposed techniques are validated using two different illumination examples: street lighting lens and stop lamp for automobiles.

  13. Design method of freeform light distribution lens for LED automotive headlamp based on DMD

    Science.gov (United States)

    Ma, Jianshe; Huang, Jianwei; Su, Ping; Cui, Yao

    2018-01-01

    We propose a new method to design freeform light distribution lens for light-emitting diode (LED) automotive headlamp based on digital micro mirror device (DMD). With the Parallel optical path architecture, the exit pupil of the illuminating system is set in infinity. Thus the principal incident rays of micro lens in DMD is parallel. DMD is made of high speed digital optical reflection array, the function of distribution lens is to distribute the emergent parallel rays from DMD and get a lighting pattern that fully comply with the national regulation GB 25991-2010.We use DLP 4500 to design the light distribution lens, mesh the target plane regulated by the national regulation GB 25991-2010 and correlate the mesh grids with the active mirror array of DLP4500. With the mapping relations and the refraction law, we can build the mathematics model and get the parameters of freeform light distribution lens. Then we import its parameter into the three-dimensional (3D) software CATIA to construct its 3D model. The ray tracing results using Tracepro demonstrate that the Illumination value of target plane is easily adjustable and fully comply with the requirement of the national regulation GB 25991-2010 by adjusting the exit brightness value of DMD. The theoretical optical efficiencies of the light distribution lens designed using this method could be up to 92% without any other auxiliary lens.

  14. Production of Curved Precast Concrete Elements for Shell Structures and Free-form Architecture using the Flexible Mould Method

    NARCIS (Netherlands)

    Schipper, H.R.; Grünewald, S.; Eigenraam, P.; Raghunath, P.; Kok, M.A.D.

    2014-01-01

    Free-form buildings tend to be expensive. By optimizing the production process, economical and well-performing precast concrete structures can be manufactured. In this paper, a method is presented that allows producing highly accurate double curved-elements without the need for milling two expensive

  15. A portable measurement system for subcriticality measurements by the Cf-source-driven neutron noise analysis method

    International Nuclear Information System (INIS)

    Mihalczo, J.T.; Ragan, G.E.; Blakeman, E.D.

    1987-01-01

    A portable measurement system consisting of a personal computer used as a Fourier analyzer and three detection channels (with associated electronics that provide the signals to analog-to-digital (A/D) convertors) has been assembled to measure subcriticality by the 252 Cf-source-driven neutron noise analysis method. 8 refs

  16. Localisation of a neutron source using measurements and calculation of the neutron flux and its gradient

    CERN Document Server

    Linden, P; Dahl, B; Pázsit, I; Por, G

    1999-01-01

    We have performed laboratory measurements of the neutron flux and its gradient in a static model experiment, similar to a model problem proposed in Pazsit (Ann. Nucl. Energy 24 (1997) 1257). The experimental system consists of a radioactive neutron source located in a water tank. The measurements are performed using a recently developed very small optical fibre detector. The measured values of the flux and its gradient are then used to test the possibility of localising the source. The results show that it is possible to measure the flux on the circumference of a circle and from this calculate the flux gradient vector. Then, by comparison of the measured quantities with corresponding MCNP calculations, both the direction and the distance to the source are found and thus the position of the source can be determined.

  17. Tritium and the environment: sources, measurement and transfer; Le tritium et l'environnement: sources, mesures et transferts

    Energy Technology Data Exchange (ETDEWEB)

    Guetat, P.; Douche, C.; Hubinois, J.C. [CEA Valduc, 21 - Is-sur-Tille (France)

    2008-10-15

    Within the framework of a seminar on environmental and health impact of tritium organized by article 31 EURATOM expert group in November 2007, it was expected to make a point on tritium knowledge and to define R and D and regulatory axes. This document presents the different sources of tritium, different methods of measurement associated to tritium processes and survey, transfer in the biosphere compartments in normal and accidental conditions. It suggests some R and D subjects and discusses some regulatory aspects. (authors)

  18. Dosimetric measurements of an 192Ir HDR source with a diamond detector

    International Nuclear Information System (INIS)

    Rustgi, Surendra N.

    1996-01-01

    Purpose: To study the feasibility of using a diamond detector for the dosimetry of a high dose rate (HDR) 192 Ir source and to compare the measurement results with published data and calculations from a commercial treatment planning system. Materials and methods: The sensitive volume of the diamond detector consists of a disk of 0.26 mm thickness and 3 mm diameter. The detector was applied an external bias of +100 V and was preirradiated to a dose of 500 cGy to stabilize its response. The 192 Ir source from the Nucletron microSelectron unit has an active diameter of 0.6 mm and a length of 3.5 mm. Photon fluence anisotropy factors in air were measured at distances of 5 and 10 cm from two sources and compared with TLD measurements. Dose profiles and isodose distributions were measured at several distances from the source and compared with calculations from a Nucletron treatment planning system. These dose calculations in water use a point source approximation with the anisotropy factors independent of the radial distance from the source. Results: The photon fluence around the 192 Ir HDR source, measured with a diamond detector at distances of 5 and 10 cm from the source, is very anisotropic. Compared to the source transverse direction, the photon fluence intensity along the source axis reduces to approximately 60%. Measurements performed on two sources indicate that the photon anisotropy does not change with distance in air. Within experimental uncertainty, similar results were obtained with TLD rods and are in excellent agreement with published anisotropy factors 1 . Dose profiles, measured with the diamond detector in a water phantom, at distances of 1,2,3 and 5 cm from the source, are found to be in excellent agreement with the Nucletron planning system calculations. Similar excellent agreement is observed between the measured and calculated isodose curves in planes parallel to the source plane. Conclusion: The diamond detector has been demonstrated to be suitable

  19. Measurements of bremsstrahlung spectra of Lanzhou ECR Ion Source No. 3 (LECR3)

    International Nuclear Information System (INIS)

    Zhao, H.Y.; Zhao, H.W.; Ma, X.W.; Zhang, S.F.; Feng, W.T.; Zhu, X.L.; Zhang, Z.M.; He, W.; Sun, L.T.; Feng, Y.C.; Cao, Y.; Li, J.Y.; Li, X.X.; Wang, H.; Ma, B.H.

    2006-01-01

    In order to diagnose the electron cyclotron resonance (ECR) plasma, electron bremsstrahlung spectra were measured by a HPGe detector on Lanzhou ECR Ion Source No. 3 at IMP. The ion source was operated with argon under various working conditions, including different microwave power, mixing gas, extraction high voltage (HV), and so on. Some of the measured spectra are presented in this article. The dependence of energetic electron population on mixing gas and extraction HV is also described. Additionally, we are looking forward to further measurements on SECRAL (Superconducting ECR Ion Source with Advanced design at Lanzhou)

  20. Experience and problems of the automated measuring and sorting of sealed radiation sources

    International Nuclear Information System (INIS)

    Shmidt, G.

    1979-01-01

    It has been shown that with the help of a serial device for samples changing and a mini-computer with a suitable software it is possible to organize the radioactivity measuring and sorting of sealed gamma-sources with activity in the microcuri region. Application of the computer permits to rise accuracy of the data on the radiation sources radioactivity, sorted according to the preset activity level groups and, in the casa of necessity, to perform the activity measurements with lower error. The method listed, gives the working-time economy of nearly 4 hours in measuring and sorting of some 500 sealed radiation sources [ru

  1. Distributed 3D Source Localization from 2D DOA Measurements Using Multiple Linear Arrays

    Directory of Open Access Journals (Sweden)

    Antonio Canclini

    2017-01-01

    Full Text Available This manuscript addresses the problem of 3D source localization from direction of arrivals (DOAs in wireless acoustic sensor networks. In this context, multiple sensors measure the DOA of the source, and a central node combines the measurements to yield the source location estimate. Traditional approaches require 3D DOA measurements; that is, each sensor estimates the azimuth and elevation of the source by means of a microphone array, typically in a planar or spherical configuration. The proposed methodology aims at reducing the hardware and computational costs by combining measurements related to 2D DOAs estimated from linear arrays arbitrarily displaced in the 3D space. Each sensor measures the DOA in the plane containing the array and the source. Measurements are then translated into an equivalent planar geometry, in which a set of coplanar equivalent arrays observe the source preserving the original DOAs. This formulation is exploited to define a cost function, whose minimization leads to the source location estimation. An extensive simulation campaign validates the proposed approach and compares its accuracy with state-of-the-art methodologies.

  2. A measurement-based generalized source model for Monte Carlo dose simulations of CT scans.

    Science.gov (United States)

    Ming, Xin; Feng, Yuanming; Liu, Ransheng; Yang, Chengwen; Zhou, Li; Zhai, Hezheng; Deng, Jun

    2017-03-07

    The goal of this study is to develop a generalized source model for accurate Monte Carlo dose simulations of CT scans based solely on the measurement data without a priori knowledge of scanner specifications. The proposed generalized source model consists of an extended circular source located at x-ray target level with its energy spectrum, source distribution and fluence distribution derived from a set of measurement data conveniently available in the clinic. Specifically, the central axis percent depth dose (PDD) curves measured in water and the cone output factors measured in air were used to derive the energy spectrum and the source distribution respectively with a Levenberg-Marquardt algorithm. The in-air film measurement of fan-beam dose profiles at fixed gantry was back-projected to generate the fluence distribution of the source model. A benchmarked Monte Carlo user code was used to simulate the dose distributions in water with the developed source model as beam input. The feasibility and accuracy of the proposed source model was tested on a GE LightSpeed and a Philips Brilliance Big Bore multi-detector CT (MDCT) scanners available in our clinic. In general, the Monte Carlo simulations of the PDDs in water and dose profiles along lateral and longitudinal directions agreed with the measurements within 4%/1 mm for both CT scanners. The absolute dose comparison using two CTDI phantoms (16 cm and 32 cm in diameters) indicated a better than 5% agreement between the Monte Carlo-simulated and the ion chamber-measured doses at a variety of locations for the two scanners. Overall, this study demonstrated that a generalized source model can be constructed based only on a set of measurement data and used for accurate Monte Carlo dose simulations of patients' CT scans, which would facilitate patient-specific CT organ dose estimation and cancer risk management in the diagnostic and therapeutic radiology.

  3. A measurement-based generalized source model for Monte Carlo dose simulations of CT scans

    Science.gov (United States)

    Ming, Xin; Feng, Yuanming; Liu, Ransheng; Yang, Chengwen; Zhou, Li; Zhai, Hezheng; Deng, Jun

    2017-03-01

    The goal of this study is to develop a generalized source model for accurate Monte Carlo dose simulations of CT scans based solely on the measurement data without a priori knowledge of scanner specifications. The proposed generalized source model consists of an extended circular source located at x-ray target level with its energy spectrum, source distribution and fluence distribution derived from a set of measurement data conveniently available in the clinic. Specifically, the central axis percent depth dose (PDD) curves measured in water and the cone output factors measured in air were used to derive the energy spectrum and the source distribution respectively with a Levenberg-Marquardt algorithm. The in-air film measurement of fan-beam dose profiles at fixed gantry was back-projected to generate the fluence distribution of the source model. A benchmarked Monte Carlo user code was used to simulate the dose distributions in water with the developed source model as beam input. The feasibility and accuracy of the proposed source model was tested on a GE LightSpeed and a Philips Brilliance Big Bore multi-detector CT (MDCT) scanners available in our clinic. In general, the Monte Carlo simulations of the PDDs in water and dose profiles along lateral and longitudinal directions agreed with the measurements within 4%/1 mm for both CT scanners. The absolute dose comparison using two CTDI phantoms (16 cm and 32 cm in diameters) indicated a better than 5% agreement between the Monte Carlo-simulated and the ion chamber-measured doses at a variety of locations for the two scanners. Overall, this study demonstrated that a generalized source model can be constructed based only on a set of measurement data and used for accurate Monte Carlo dose simulations of patients’ CT scans, which would facilitate patient-specific CT organ dose estimation and cancer risk management in the diagnostic and therapeutic radiology.

  4. Directivity of Spherical Polyhedron Sound Source Used in Near-Field HRTF Measurements

    International Nuclear Information System (INIS)

    Yu Guang-Zheng; Xie Bo-Sun; Rao Dan

    2010-01-01

    The omnidirectional character is one of important requirements for the sound source used in near-field head-related transfer function (HRTF) measurements. Based on the analysis on the radiation sound pressure and directivity character of various spherical polyhedron sound sources, a spherical dodecahedral sound source with radius of 0.035m is proposed and manufactured. Theoretical and measured results indicate that the sound source is approximately omnidirectional below the frequency of 8 kHz. In addition, the sound source has reasonable magnitude response from 350Hz to 20kHz and linear phase characteristics. Therefore, it is suitable for the near-field HRTF measurements. (fundamental areas of phenomenology(including applications))

  5. Radio measurements in the fields of gamma-ray sources. Pt. 1

    International Nuclear Information System (INIS)

    Sieber, W.; Schlickeiser, R.

    1982-01-01

    The γ-ray source CG 195+04 has been searched for radio counterparts at wavelengths between 2.8 cm and 18 cm with the 100-m telescope of the Max-Planck-Institut fuer Radioastronomie, Bonn. We have detected a number of sources and measured their spectra. Our positions may form the basis for future surveys in other frequency ranges. Different physical emission models suggest compactness of the γ-ray source. (orig.)

  6. THE Q/U IMAGING EXPERIMENT: POLARIZATION MEASUREMENTS OF RADIO SOURCES AT 43 AND 95 GHz

    Energy Technology Data Exchange (ETDEWEB)

    Huffenberger, K. M. [Department of Physics, Florida State University, P.O. Box 3064350, Tallahassee, FL 32306-4350 (United States); Araujo, D.; Zwart, J. T. L. [Department of Physics and Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Bischoff, C.; Buder, I. [Kavli Institute for Cosmological Physics, Department of Physics, Enrico Fermi Institute, The University of Chicago, Chicago, IL 60637 (United States); Chinone, Y.; Hasegawa, M. [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Cleary, K. [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, 1200 E. California Blvd M/C 249-17, Pasadena, CA 91125 (United States); Kusaka, A. [Physics Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Monsalve, R. [School of Earth and Space Exploration, Arizona State University, 781 E. Terrace Road, Tempe, AZ 85287 (United States); Næss, S. K. [Department of Astrophysics, University of Oxford, Keble Road, Oxford, OX1 3RH (United Kingdom); Newburgh, L. B. [Dunlap Institute, University of Toronto, 50 St. George Street, Toronto, ON M5S 3H4 (Canada); Reeves, R. [CePIA, Departamento de Astronomía, Universidad de Concepción (Chile); Ruud, T. M.; Eriksen, H. K. [Institute of Theoretical Astrophysics, University of Oslo, P.O. Box 1029 Blindern, NO-0315 Oslo (Norway); Wehus, I. K.; Gaier, T. [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States); Dickinson, C. [Jodrell Bank Centre for Astrophysics, Alan Turing Building, School of Physics and Astronomy, The University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); Gundersen, J. O., E-mail: huffenbe@physics.fsu.edu [Department of Physics, University of Miami, 1320 Campo Sano Drive, Coral Gables, FL 33146 (United States); Collaboration: QUIET Collaboration; and others

    2015-06-10

    We present polarization measurements of extragalactic radio sources observed during the cosmic microwave background polarization survey of the Q/U Imaging Experiment (QUIET), operating at 43 GHz (Q-band) and 95 GHz (W-band). We examine sources selected at 20 GHz from the public, >40 mJy catalog of the Australia Telescope (AT20G) survey. There are ∼480 such sources within QUIET’s four low-foreground survey patches, including the nearby radio galaxies Centaurus A and Pictor A. The median error on our polarized flux density measurements is 30–40 mJy per Stokes parameter. At signal-to-noise ratio > 3 significance, we detect linear polarization for seven sources in Q-band and six in W-band; only 1.3 ± 1.1 detections per frequency band are expected by chance. For sources without a detection of polarized emission, we find that half of the sources have polarization amplitudes below 90 mJy (Q-band) and 106 mJy (W-band), at 95% confidence. Finally, we compare our polarization measurements to intensity and polarization measurements of the same sources from the literature. For the four sources with WMAP and Planck intensity measurements >1 Jy, the polarization fractions are above 1% in both QUIET bands. At high significance, we compute polarization fractions as much as 10%–20% for some sources, but the effects of source variability may cut that level in half for contemporaneous comparisons. Our results indicate that simple models—ones that scale a fixed polarization fraction with frequency—are inadequate to model the behavior of these sources and their contributions to polarization maps.

  7. Complementarity between innovation knowledge sources: Does the innovation performance measure matter?

    Directory of Open Access Journals (Sweden)

    Ana Mª Serrano-Bedia

    2018-01-01

    Full Text Available We analyse complementarity between different knowledge sources (internal, external and/or cooperation employing a wide range of innovation performance measures (product, process, organizational, and commercial. The empirical study uses 2014 Spanish CIS data and studies complementarities by performing conditional complementarity/substitutability tests. The results show evidence of conditional complementarity in product innovation performance between external and internal knowledge sources in absence of cooperation and of conditional substitute relationship between external and cooperation knowledge sources in presence of internal source. In product and process innovation performance we found a conditional substitute relationship between internal and cooperation sources when external source is used and not used, respectively. This relationship turns to conditional complementarity in organisational innovation in absence of external knowledge source. Therefore, when designing innovation strategy, managers must consider their objectives on a priority basis, since not all the strategies have the same effects on innovation performance.

  8. Evaluation of antinociceptive activity of nanoliposome-encapsulated and free-form diclofenac in rats and mice.

    Science.gov (United States)

    Goh, Jun Zheng; Tang, Sook Nai; Chiong, Hoe Siong; Yong, Yoke Keong; Zuraini, Ahmad; Hakim, Muhammad Nazrul

    2015-01-01

    Diclofenac is a nonsteroidal anti-inflammatory drug (NSAID) that exhibits anti-inflammatory, antinociceptive, and antipyretic activities. Liposomes have been shown to improve the therapeutic efficacy of encapsulated drugs. The present study was conducted to compare the antinociceptive properties between liposome-encapsulated and free-form diclofenac in vivo via different nociceptive assay models. Liposome-encapsulated diclofenac was prepared using the commercialized proliposome method. Antinociceptive effects of liposome-encapsulated and free-form diclofenac were evaluated using formalin test, acetic acid-induced abdominal writhing test, Randall-Selitto paw pressure test, and plantar test. The results of the writhing test showed a significant reduction of abdominal constriction in all treatment groups in a dose-dependent manner. The 20 mg/kg liposome-encapsulated diclofenac demonstrated the highest antinociceptive effect at 78.97% compared with 55.89% in the free-form group at equivalent dosage. Both liposome-encapsulated and free-form diclofenac produced significant results in the late phase of formalin assay at a dose of 20 mg/kg, with antinociception percentages of 78.84% and 60.71%, respectively. Significant results of antinociception were also observed in both hyperalgesia assays. For Randall-Sellito assay, the highest antinociception effect of 71.38% was achieved with 20 mg/kg liposome-encapsulated diclofenac, while the lowest antinociceptive effect of 17.32% was recorded with 0 mg/kg liposome formulation, whereas in the plantar test, the highest antinociceptive effect was achieved at 56.7% with 20 mg/kg liposome-encapsulated diclofenac, and the lowest effect was shown with 0 mg/kg liposome formulation of 8.89%. The present study suggests that liposome-encapsulated diclofenac exhibits higher antinociceptive efficacy in a dose-dependent manner in comparison with free-form diclofenac.

  9. Measurement-device-independent quantum key distribution with correlated source-light-intensity errors

    Science.gov (United States)

    Jiang, Cong; Yu, Zong-Wen; Wang, Xiang-Bin

    2018-04-01

    We present an analysis for measurement-device-independent quantum key distribution with correlated source-light-intensity errors. Numerical results show that the results here can greatly improve the key rate especially with large intensity fluctuations and channel attenuation compared with prior results if the intensity fluctuations of different sources are correlated.

  10. Free-form nanostructured tools for plastic injection moulding

    DEFF Research Database (Denmark)

    Kafka, Jan; Sonne, Mads Rostgaard; Lam, Yee Cheong

    realized and successfully transferred to plastic parts during injection moulding.As an example, we present theory and results regarding the imprint of pillar nanostructures on a semi-spherical mold surface, followed by injection molding of the same. The deformation of the flexible stamp is characterized...... by measurement of inter-pillar distance on various points on the sphere, and compared to predictions provided by a geometrical model. Moulded plastic parts show good replication of the pillar structure.There are various practical advantages to the new process: the application of the coating is possible on both...

  11. Total luminous flux measurement for flexible surface sources with an integrating sphere photometer

    International Nuclear Information System (INIS)

    Yu, Hsueh-Ling; Liu, Wen-Chun

    2014-01-01

    Applying an integrating sphere photometer for total luminous flux measurement is a widely used method. However, the measurement accuracy depends on the spatial uniformity of the integrating sphere, especially when the test sample has a different light distribution from that of the standard source. Therefore, spatial correction is needed to eliminate the effect caused by non-uniformity. To reduce the inconvenience of spatial correction but retain the measurement accuracy, a new type of working standard is designed for flexible and curved surface sources. Applying this new type standard source, the measurement deviation due to different orientations is reduced by an order of magnitude compared with using a naked incandescent lamp as the standard source. (paper)

  12. The optical properties of a double focusing bending magnet measured with a thin alpha source

    International Nuclear Information System (INIS)

    Armitage, S.A.; Eastham, D.A.

    1978-01-01

    The focusing properties of the 90 0 inflector magnet for the Nuclear Structure Facility (NSF) tandem at Daresbury Laboratory have been measured in the 2rho configuration using very thin alpha sources and a position-sensitive detector. (Auth.)

  13. Some problems of neutron source multiplication method for site measurement technology in nuclear critical safety

    International Nuclear Information System (INIS)

    Shi Yongqian; Zhu Qingfu; Hu Dingsheng; He Tao; Yao Shigui; Lin Shenghuo

    2004-01-01

    The paper gives experiment theory and experiment method of neutron source multiplication method for site measurement technology in the nuclear critical safety. The measured parameter by source multiplication method actually is a sub-critical with source neutron effective multiplication factor k s , but not the neutron effective multiplication factor k eff . The experiment research has been done on the uranium solution nuclear critical safety experiment assembly. The k s of different sub-criticality is measured by neutron source multiplication experiment method, and k eff of different sub-criticality, the reactivity coefficient of unit solution level, is first measured by period method, and then multiplied by difference of critical solution level and sub-critical solution level and obtained the reactivity of sub-critical solution level. The k eff finally can be extracted from reactivity formula. The effect on the nuclear critical safety and different between k eff and k s are discussed

  14. Finite element approximation for time-dependent diffusion with measure-valued source

    Czech Academy of Sciences Publication Activity Database

    Seidman, T.; Gobbert, M.; Trott, D.; Kružík, Martin

    2012-01-01

    Roč. 122, č. 4 (2012), s. 709-723 ISSN 0029-599X R&D Projects: GA AV ČR IAA100750802 Institutional support: RVO:67985556 Keywords : measure-valued source * diffusion equation Subject RIV: BA - General Mathematics Impact factor: 1.329, year: 2012 http://library.utia.cas.cz/separaty/2012/MTR/kruzik-finite element approximation for time - dependent diffusion with measure-valued source.pdf

  15. Optimized spectroscopic scheme for enhanced precision CO measurements with applications to urban source attribution

    Science.gov (United States)

    Nottrott, A.; Hoffnagle, J.; Farinas, A.; Rella, C.

    2014-12-01

    Carbon monoxide (CO) is an urban pollutant generated by internal combustion engines which contributes to the formation of ground level ozone (smog). CO is also an excellent tracer for emissions from mobile combustion sources. In this work we present an optimized spectroscopic sampling scheme that enables enhanced precision CO measurements. The scheme was implemented on the Picarro G2401 Cavity Ring-Down Spectroscopy (CRDS) analyzer which measures CO2, CO, CH4 and H2O at 0.2 Hz. The optimized scheme improved the raw precision of CO measurements by 40% from 5 ppb to 3 ppb. Correlations of measured CO2, CO, CH4 and H2O from an urban tower were partitioned by wind direction and combined with a concentration footprint model for source attribution. The application of a concentration footprint for source attribution has several advantages. The upwind extent of the concentration footprint for a given sensor is much larger than the flux footprint. Measurements of mean concentration at the sensor location can be used to estimate source strength from a concentration footprint, while measurements of the vertical concentration flux are necessary to determine source strength from the flux footprint. Direct measurement of vertical concentration flux requires high frequency temporal sampling and increases the cost and complexity of the measurement system.

  16. Monte Carlo calculations and experimental measurements of dosimetric parameters of the IRA-103Pd source

    International Nuclear Information System (INIS)

    Sadeghi, Mahdi; Hosseini, Hamed; Raisali, Gholamreza

    2008-01-01

    Full text: The use of 103 Pd seed sources for permanent prostate implantation has become a popular brachytherapy application. As recommended by AAPM the dosimetric characteristics of the new source must be determined using experimental and Monte Carlo simulations, before its use in clinical applications thus The goal of this report is the experimental and theoretical determination of the dosimetric characteristics of this source following the recommendations in the AAPM TG-43U1 protocol. Figure 1 shows the geometry of the IRA- 103 Pd source. The source consists of a cylindrical silver core, 0.3 cm long x 0.05 cm in diameter, onto which 0.5 nm layer of 103 Pd has been uniformly adsorbed. The effective active length of source is 0.3 cm and the silver core encapsulated inside a hollow titanium tube with 0.45 cm long, 0.07 cm and 0.08 inner and outer diameters and two caps. The Monte Carlo N-Particle (MCNP) code, version 4C, was used to determine the relevant dosimetric parameters of the source. The geometry of the Monte Carlo simulation performed in this study consisted of a sphere with 30 cm diameter. Dose distributions around this source were measured in two Perspex phantom using enough TLD chips. For these measurements, slabs of Perspex material were machined to accommodate the source and TLD chips. A value of 0.67± 1% cGy.h -1 .U -1 for, Λ, was calculated as the ratio of d(r 0 ,θ 0 ) and s K , that may be compared with Λ values obtained for 103 Pd sources. Result of calculations and measurements values of dosimetric parameters of the source including radial dose function, g(r), and anisotropy function, F(r,θ), has been shown in separate figures. The radial dose function, g(r), for the IRA- 103 Pd source and other 103 Pd sources is included in Fig. 2. Comparison between measured and Monte Carlo simulated dose function, g(r), and anisotropy function, F(r,θ), of this source demonstrated that they are in good agreement with each other and The value of Λ is

  17. Implementation of 252Cf-source-driven power spectrum density measurement system

    International Nuclear Information System (INIS)

    Ren Yong; Wei Biao; Feng Peng; Li Jiansheng; Ye Cenming

    2012-01-01

    The principle of 252 Cf-source-driven power spectrum density measurement method is introduced. A measurement system and platform is realized accordingly, which is a combination of hardware and software, for measuring nuclear parameters. The detection method of neutron pulses based on an ultra-high-speed data acquisition card (three channels, 1 GHz sampling rate, 1 ns synchronization) is described, and the data processing process and the power spectrum density algorithm on PC are designed. This 252 Cf-source-driven power spectrum density measurement system can effectively obtain the nuclear tag parameters of nuclear random processes, such as correlation function and power spectrum density. (authors)

  18. Response of a BGO detector to photon and neutron sources simulations and measurements

    CERN Document Server

    Vincke, H H; Fabjan, Christian Wolfgang; Otto, T

    2002-01-01

    In this paper Monte Carlo simulations (FLUKA) and measurements of the response of a BGO detector are reported. %For the measurements different radioactive sources were used to irradiate the BGO crystal. For the measurements three low-energy photon emitters $\\left({}^{60}\\rm{Co},\\right.$ ${}^{54}\\rm{Mn},$ $\\left. {}^{137}\\rm{Cs}\\right)$ were used to irradiate the BGO from various distances and angles. The neutron response was measured with an Am--Be neutron source. Simulations of the experimental irradiations were carried out. Our study can also be considered as a benchmark for FLUKA in terms of its reliability to predict the detector response of a BGO scintillator.

  19. Sources

    International Nuclear Information System (INIS)

    Duffy, L.P.

    1991-01-01

    This paper discusses the sources of radiation in the narrow perspective of radioactivity and the even narrow perspective of those sources that concern environmental management and restoration activities at DOE facilities, as well as a few related sources. Sources of irritation, Sources of inflammatory jingoism, and Sources of information. First, the sources of irritation fall into three categories: No reliable scientific ombudsman to speak without bias and prejudice for the public good, Technical jargon with unclear definitions exists within the radioactive nomenclature, and Scientific community keeps a low-profile with regard to public information. The next area of personal concern are the sources of inflammation. This include such things as: Plutonium being described as the most dangerous substance known to man, The amount of plutonium required to make a bomb, Talk of transuranic waste containing plutonium and its health affects, TMI-2 and Chernobyl being described as Siamese twins, Inadequate information on low-level disposal sites and current regulatory requirements under 10 CFR 61, Enhanced engineered waste disposal not being presented to the public accurately. Numerous sources of disinformation regarding low level radiation high-level radiation, Elusive nature of the scientific community, The Federal and State Health Agencies resources to address comparative risk, and Regulatory agencies speaking out without the support of the scientific community

  20. Regularity of the wear control of radioactive sources from the nuclear measurers

    International Nuclear Information System (INIS)

    Ferreira L, M.

    2006-01-01

    The control of radioactive sources in Brazil is regulated by the CNEN (National Comissao of Nuclear Energy). The Laboratory of Descontaminacao of the IPEN (Institute of Energy Y Nuclear Investigations) it offers to the companies that work with nuclear measurers, essays for control of the source wear according to the ISO 9978/1992 through the smear tests Y of leakage. The analyses are taken in alpha Y beta detectors of low bottom radiation with annual detection limits around 1 Bq. Certificates of the accepted analyses by the CNEN for sources that already passed its time of validity assured by the makers, but its continue operational are emitted. The smear test is repeated the whole year, while the leakage test repeats to every two years. A balance of the last two years of the activities of the laboratory shows the regularity of the clients Y the growth of companies specialized in radioprotection with official of radioprotection, credited by the regulatory authority that its act as intermediaries in the process, contacting the clients, gathering the samples next to the proprietors of sources Y hiring our services. Overalls, proves that the inspection activities by part of the regulatory authority are fulfil. In 2004, 192 sources were analyzed by the smear method Y 86 sources by leakage. In 2005, 232 sources were analyzed by the smear method Y 60 sources by leakage. All the leakage tests was made in sources of Americium of oneself Y only client that brings the sources so that they dismantle them to him in the Sources production laboratory of the IPEN. By the quantity Y age of the sources that were analyzed in those two years, it is proven that the number of sources without use conditions (total activity measured by the two added methods smaller than 180Bq) it doesn't arrive to 2%. (Author)

  1. Characterization of the γ background in epithermal neutron scattering measurements at pulsed neutron sources

    International Nuclear Information System (INIS)

    Pietropaolo, A.; Tardocchi, M.; Schooneveld, E.M.; Senesi, R.

    2006-01-01

    This paper reports the characterization of the different components of the γ background in epithermal neutron scattering experiments at pulsed neutron sources. The measurements were performed on the VESUVIO spectrometer at ISIS spallation neutron source. These measurements, carried out with a high purity germanium detector, aim to provide detailed information for the investigation of the effect of the γ energy discrimination on the signal-to-background ratio. It is shown that the γ background is produced by different sources that can be identified with their relative time structure and relative weight

  2. On-line measurement of microwave power in ECR ion source

    International Nuclear Information System (INIS)

    Zhou Changgeng; Kang Wu; Hu Yonghong; Li Yan; Lou Benchao; Zu Xiulan; Xiong Riheng; Chen Junguang; Li Xiaoyun

    2005-01-01

    It is a new technology to apply an ECR ion source to the neutron generator. Because of the structure limitation, working state of the ECR ion source could not be judged by the color of gas discharging in discharge chamber. Therefore, it was hard to estimate if the ECR ion source was working properly in the neutron generator. The method to resolve the problem was described in this paper. The microwave power was measured on-line by a directional coupler and a small microwave power meter. The ion beam current could be educed from the measured incidence microwave power, and discharge state in discharge chamber could be determined. (authors)

  3. Methane source identification in Boston, Massachusetts using isotopic and ethane measurements

    Science.gov (United States)

    Down, A.; Jackson, R. B.; Plata, D.; McKain, K.; Wofsy, S. C.; Rella, C.; Crosson, E.; Phillips, N. G.

    2012-12-01

    Methane has substantial greenhouse warming potential and is the principle component of natural gas. Fugitive natural gas emissions could be a significant source of methane to the atmosphere. However, the cumulative magnitude of natural gas leaks is not yet well constrained. We used a combination of point source measurements and ambient monitoring to characterize the methane sources in the Boston urban area. We developed distinct fingerprints for natural gas and multiple biogenic methane sources based on hydrocarbon concentration and isotopic composition. We combine these data with periodic measurements of atmospheric methane and ethane concentration to estimate the fractional contribution of natural gas and biogenic methane sources to the cumulative urban methane flux in Boston. These results are used to inform an inverse model of urban methane concentration and emissions.

  4. Brightness measurement of an electron impact gas ion source for proton beam writing applications

    Energy Technology Data Exchange (ETDEWEB)

    Liu, N.; Santhana Raman, P. [Centre for Ion Beam Applications, Department of Physics, National University of Singapore, Singapore 117542 (Singapore); Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117583 (Singapore); Xu, X.; Pang, R.; Kan, J. A. van, E-mail: phyjavk@nus.edu.sg [Centre for Ion Beam Applications, Department of Physics, National University of Singapore, Singapore 117542 (Singapore); Khursheed, A. [Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117583 (Singapore)

    2016-02-15

    We are developing a high brightness nano-aperture electron impact gas ion source, which can create ion beams from a miniature ionization chamber with relatively small virtual source sizes, typically around 100 nm. A prototype source of this kind was designed and successively micro-fabricated using integrated circuit technology. Experiments to measure source brightness were performed inside a field emission scanning electron microscope. The total output current was measured to be between 200 and 300 pA. The highest estimated reduced brightness was found to be comparable to the injecting focused electron beam reduced brightness. This translates into an ion reduced brightness that is significantly better than that of conventional radio frequency ion sources, currently used in single-ended MeV accelerators.

  5. Angular and mass resolved energy distribution measurements with a gallium liquid metal ion source

    International Nuclear Information System (INIS)

    Marriott, Philip

    1987-06-01

    Ionisation and energy broadening mechanisms relevant to liquid metal ion sources are discussed. A review of experimental results giving a picture of source operation and a discussion of the emission mechanisms thought to occur for the ionic species and droplets emitted is presented. Further work is suggested by this review and an analysis system for angular and mass resolved energy distribution measurements of liquid metal ion source beams has been constructed. The energy analyser has been calibrated and a series of measurements, both on and off the beam axis, of 69 Ga + , Ga ++ and Ga 2 + ions emitted at various currents from a gallium source has been performed. A comparison is made between these results and published work where possible, and the results are discussed with the aim of determining the emission and energy spread mechanisms operating in the gallium liquid metal ion source. (author)

  6. Measurement of the activity of an artificial neutrino source based on 37Ar

    International Nuclear Information System (INIS)

    Abdurashitov, D. N.; Veretenkin, E. P.; Gavrin, V. N.; Gorbachev, V. V.; Ibragimova, T. V.; Kalikhov, A. V.; Mirmov, I. N.; Shikhin, A. A.; Yants, V. E.; Barsanov, V. I.; Dzhanelidze, A. A.; Zlokazov, S. B.; Markov, S. Yu.; Shakirov, Z. N.; Cleveland, B. T.

    2007-01-01

    The activity of an artificial neutrino source based on 37 Ar was measured by a specially developed method of directly counting 37 Ar decays in a proportional counter. This source was used to irradiate the target of the SAGE radiochemical gallium-germanium neutrino telescope at the Baksan Neutrino Observatory (Institute for Nuclear Research, Russian Academy of Sciences, Moscow), whereupon the measurements were performed at the Institute of Reactor Materials (Zarechny, Sverdlovsk oblast, Russia). The method used to prepare gaseous samples for measurements in proportional counters and the counting procedure are described. The measured activity of the 37 Ar neutrino source is 405.1 ± 3.7 kCi (corrected for decays that occurred within the period between the instant of activity measurement and the commencement of the irradiation of Ga target at 04:00 Moscow time, 30.04.2004)

  7. Flux density measurements of radio sources at 2.14 millimeter wavelength

    International Nuclear Information System (INIS)

    Cogdell, J.R.; Davis, J.H.; Ulrich, B.T.; Wills, B.J.

    1975-01-01

    Flux densities of galactic and extragalactic sources, and planetary temperatures, have been measured at 2.14 mm wavelength (140 GHz). Results are presented for OJ 287; the galactic sources DR 21, W3, and Orion A; the extragalactic sources PKS 0106plus-or-minus01, 3C 84, 3C 120, BL Lac, 3C 216, 3C 273, 3C 279, and NGC 4151; and the Sun, Venus, Mars, and Jupiter. Also presented is the first measurement of the 2.14-mm temperature of Uranus. The spectra of some of these sources are discussed. The flux density scale was calibrated absolutely. The measurements were made with a new continuum receiver on the 4.88-m radio telescope of The University of Texas

  8. A method for measuring power signal background and source strength in a fission reactor

    International Nuclear Information System (INIS)

    Baers, B.; Kall, L.; Visuri, P.

    1977-01-01

    Theory and experimental verification of a novel method for measuring power signal bias and source strength in a fission reactor are reported. A minicomputer was applied in the measurements. The method is an extension of the inverse kinetics method presented by Mogilner et al. (Auth.)

  9. A method for the coherence measurement of the supercontinuum source using Michelson interferometer

    International Nuclear Information System (INIS)

    Semenova, V A; Tsypkin, A V; Putilin, S E; Bespalov, V G

    2014-01-01

    Coherent properties of supercontinuum sources are highly significant for various applications, including low-coherence interferometry and optical frequency metrology. We propose a fast method for the spatial and temporal self-coherence of the SC measurement using Michelson interferometer without a mirror movement. Furthermore, we present self-coherence measurements of the supercontinuum, generated in microstructured fiber at 780 nm.

  10. Statistical measurement of the gamma-ray source-count distribution as a function of energy

    Science.gov (United States)

    Zechlin, H.-S.; Cuoco, A.; Donato, F.; Fornengo, N.; Regis, M.

    2017-01-01

    Photon counts statistics have recently been proven to provide a sensitive observable for characterizing gamma-ray source populations and for measuring the composition of the gamma-ray sky. In this work, we generalize the use of the standard 1-point probability distribution function (1pPDF) to decompose the high-latitude gamma-ray emission observed with Fermi-LAT into: (i) point-source contributions, (ii) the Galactic foreground contribution, and (iii) a diffuse isotropic background contribution. We analyze gamma-ray data in five adjacent energy bands between 1 and 171 GeV. We measure the source-count distribution dN/dS as a function of energy, and demonstrate that our results extend current measurements from source catalogs to the regime of so far undetected sources. Our method improves the sensitivity for resolving point-source populations by about one order of magnitude in flux. The dN/dS distribution as a function of flux is found to be compatible with a broken power law. We derive upper limits on further possible breaks as well as the angular power of unresolved sources. We discuss the composition of the gamma-ray sky and capabilities of the 1pPDF method.

  11. Development of source range measurement instrument in Xi'an pulsed reactor

    CERN Document Server

    Wang Li

    2002-01-01

    Source range measurement instrument in Xi'an pulsed reactor is key equipment of low-side measuring in source range. At the same time, it is also weighty component of out-of-pile neutron-flux level observation system. The authors have done some researching and renovating based on the similar type devices used in nuclear reactor to improve the meter sensitivity, measuring range, noise proof features, reliability in running and maintainability which belong to the main performance index of the instrument. The design ideas, configurations, working principle, performance indexes, technique features and effect in utilizing are introduced briefly

  12. Radiation measurement practice for understanding statistical fluctuation of radiation count using natural radiation sources

    International Nuclear Information System (INIS)

    Kawano, Takao

    2014-01-01

    It is known that radiation is detected at random and the radiation counts fluctuate statistically. In the present study, a radiation measurement experiment was performed to understand the randomness and statistical fluctuation of radiation counts. In the measurement, three natural radiation sources were used. The sources were fabricated from potassium chloride chemicals, chemical fertilizers and kelps. These materials contain naturally occurring potassium-40 that is a radionuclide. From high schools, junior high schools and elementary schools, nine teachers participated to the radiation measurement experiment. Each participant measured the 1-min integration counts of radiation five times using GM survey meters, and 45 sets of data were obtained for the respective natural radiation sources. It was found that the frequency of occurrence of radiation counts was distributed according to a Gaussian distribution curve, although the obtained 45 data sets of radiation counts superficially looked to be fluctuating meaninglessly. (author)

  13. Electrical shielding box measurement of the negative hydrogen beam from Penning ion gauge ion source.

    Science.gov (United States)

    Wang, T; Yang, Z; Dong, P; long, J D; He, X Z; Wang, X; Zhang, K Z; Zhang, L W

    2012-06-01

    The cold-cathode Penning ion gauge (PIG) type ion source has been used for generation of negative hydrogen (H(-)) ions as the internal ion source of a compact cyclotron. A novel method called electrical shielding box dc beam measurement is described in this paper, and the beam intensity was measured under dc extraction inside an electrical shielding box. The results of the trajectory simulation and dc H(-) beam extraction measurement were presented. The effect of gas flow rate, magnetic field strength, arc current, and extraction voltage were also discussed. In conclusion, the dc H(-) beam current of about 4 mA from the PIG ion source with the puller voltage of 40 kV and arc current of 1.31 A was extrapolated from the measurement at low extraction dc voltages.

  14. Stability check source measurements with a secondary standard dosimeter in SSDL-Pakistan

    International Nuclear Information System (INIS)

    Salman, S.; Mahmoud, K.; Orfi, S.D.

    1988-01-01

    The stability check source is an integral part of a Secondary Standard Dosimetry System. The purpose of the stability check source is to confirm that the overall response of the dosimeter has not changed significantly since the instrument was calibrated. In case any change in the sensitivity of the ionization chamber or measuring assembly occurs the same is reflected in the reference check source measurements. Stability check source measurements are taken in a Primary Standard Dosimetry Laboratory (PSDL) at the time of calibration of secondary standard dosimeter and mean time (in seconds) to the reference setting of 50 scale divisions with ambient conditions of air at 20 deg. C, 101.3 kPa and 50% RH is quoted in a calibration certificate. This quoted stability check source time figure is the basis for future confirmation of overall response of the secondary standard dosimeter system. This note presents the results of stability check source measurements carried out in SSDL Pakistan over a period of five years

  15. Methods and apparatus for safely handling radioactive sources in measuring-while-drilling tools

    International Nuclear Information System (INIS)

    Wraight, P.D.

    1989-01-01

    This patent describes a method for removing a chemical radioactive source from a MWD tool which is coupled in a drill string supported by a drilling rig while a borehole is drilled and includes logging means for measuring formation characteristics in response to irradiation of the adjacent formations by the radioactive source during the drilling operation. The steps of the method are: halting the drilling operation and then removing the drill string from the borehole for moving the MWD tool to a work station at the surface where the source is at a safe working distance from the drilling rig and will be accessible by way of one end of the MWD tool; positioning a radiation shield at a location adjacent to the one end of the MWD tool where the shield is ready for receiving the source as it is moved away from the other end of the MWD tool and then moving the source away from the other end of the MWD tool for enclosing the source within the shield; and once the source is enclosed within the shield; removing the shield together with the enclosed source from the MWD tool for transferring the enclosed source to another work station

  16. Single-source gamma radiation procedures for improved calibration and measurements in porous media

    International Nuclear Information System (INIS)

    Oostrom, M.; Hofstee, C.; Dane, H.; Lenhard, R.J.

    1998-01-01

    When dual-energy gamma radiation systems are employed for measurements in porous media, count rates from both sources are often used to compute parameter values. However, for several applications, the count rates of just one source are insufficient. These applications include the determination of volumetric liquid content values in two-liquid systems and salt concentration values in water-saturated porous media. Single-energy gamma radiation procedures for three applications are described in this paper. Through an error analysis, single-source procedures are shown to reduce the probable error in the determinations considerably. Example calculations and simple column experiments were conducted for each application to compare the performance of the new single-source and standard dual-source methods. In all cases, the single-source methods provided more reliable data than the traditional dual-source methods. In addition, a single-source calibration procedure is proposed to determine incident count rates indirectly. This procedure, which requires packing under saturated conditions, can be used in all single- and dual-source applications and yields accurate porosity and dry bulk density values

  17. Unaccounted source of systematic errors in measurements of the Newtonian gravitational constant G

    International Nuclear Information System (INIS)

    DeSalvo, Riccardo

    2015-01-01

    Many precision measurements of G have produced a spread of results incompatible with measurement errors. Clearly an unknown source of systematic errors is at work. It is proposed here that most of the discrepancies derive from subtle deviations from Hooke's law, caused by avalanches of entangled dislocations. The idea is supported by deviations from linearity reported by experimenters measuring G, similarly to what is observed, on a larger scale, in low-frequency spring oscillators. Some mitigating experimental apparatus modifications are suggested. - Highlights: • Source of discrepancies on universal gravitational constant G measurements. • Collective motion of dislocations results in breakdown of Hook's law. • Self-organized criticality produce non-predictive shifts of equilibrium point. • New dissipation mechanism different from loss angle and viscous models is necessary. • Mitigation measures proposed may bring coherence to the measurements of G

  18. Ground motion measurements at the LBL Light Source site, the Bevatron and at SLAC

    International Nuclear Information System (INIS)

    Green, M.A.; Majer, E.I.; More, V.D.; O'Connell, D.R.; Shilling, R.C.

    1986-12-01

    This report describes the technique for measuring ground motion at the site of the 1.0 to 2.0 GeV Synchrotron Radiation Facility which was known as the Advanced Light Source (in 1983 when the measurements were taken). The results of ground motion measurements at the Light Source site at Building 6 at LBL are presented. As comparison, ground motion measurements were made at the Byerly Tunnel, the Bevatron, Blackberry Canyon, and SLAC at the Spear Ring. Ground Motion at the Light Source site was measured in a band from 4 to 100 Hz. The measured noise is primarily local in origin and is not easily transported through LBL soils. The background ground motion is for the most part less than 0.1 microns. Localized truck traffic near Building 6 and the operation of the cranes in the building can result in local ground motions of a micron or more for short periods of time. The background motion at Building 6 is between 1 and 2 orders of magnitude higher than ground motion in a quiet seismic tunnel, which is representative of quiet sites worldwide. The magnitude of the ground motions at SLAC and the Bevatron are comparable to ground motions measured at the Building 6 Light Source site. However, the frequency signature of each site is very different

  19. On-line measurement of the microwave power in ECR ion source

    International Nuclear Information System (INIS)

    Zhou Changgeng; Kang Wu; Hu Yonghong; Li Yan; Lou Benchao; Zu Xiulan; Xiong Riheng; Chen Junguang

    2005-01-01

    It is a new technology that ECR ion source is applied in the neutron generator. Because of effect of the structure, working state of ECR ion source could not be judged by the color of gas discharging in discharging chamber as doing in high frequency ion source. Therefore, state adjusting of ECR ion source was difficult in running of the neutron generator. The method to resolve the question is described in this paper. The micro-wave power was measured in case of running by using the method of directional coupler adding small microwave power meter. Because both were in the direct proportion, the ion beam current could be educed from microwave incidence power measured, and discharge state in discharge chamber could be judged. Finally, the neutron generator might be operated in best running state. (authors)

  20. Unaccounted source of systematic errors in measurements of the Newtonian gravitational constant G

    Science.gov (United States)

    DeSalvo, Riccardo

    2015-06-01

    Many precision measurements of G have produced a spread of results incompatible with measurement errors. Clearly an unknown source of systematic errors is at work. It is proposed here that most of the discrepancies derive from subtle deviations from Hooke's law, caused by avalanches of entangled dislocations. The idea is supported by deviations from linearity reported by experimenters measuring G, similarly to what is observed, on a larger scale, in low-frequency spring oscillators. Some mitigating experimental apparatus modifications are suggested.

  1. Measuring Prosocial Tendencies in Germany: Sources of Validity and Reliablity of the Revised Prosocial Tendency Measure

    Science.gov (United States)

    Rodrigues, Johannes; Ulrich, Natalie; Mussel, Patrick; Carlo, Gustavo; Hewig, Johannes

    2017-01-01

    The prosocial tendencies measure (PTM; Carlo and Randall, 2002) is a widely used measurement for prosocial tendencies in English speaking participants. This instrument distinguishes between six different types of prosocial tendencies that partly share some common basis, but also can be opposed to each other. To examine these constructs in Germany, a study with 1067 participants was conducted. The study investigated the structure of this German version of the PTM-R via exploratory factor analysis, confirmatory factor analysis, correlations with similar constructs in subsamples as well as via measurement invariance test concerning the original English version. The German translation showed a similar factor structure to the English version in exploratory factor analysis and in confirmatory factor analysis. Measurement invariance was found between the English and German language versions of the PTM and support for the proposed six-factor structure (altruistic, anonymous, compliant, dire, emotional and public prosocial behavior) was also found in confirmatory factor analysis. Furthermore, the expected interrelations of these factors of prosocial behavior tendencies were obtained. Finally, correlations of the prosocial behavior tendencies with validating constructs and behaviors were found. Thus, the findings stress the importance of seeing prosocial behavior not as a single dimension construct, but as a factored construct which now can also be assessed in German speaking participants. PMID:29270144

  2. A portable measurement system for subcriticality measurements by the CF-source-driven neutron noise analysis method

    International Nuclear Information System (INIS)

    Mihalczo, J.T.; Ragan, G.E.; Blakeman, E.D.

    1988-01-01

    A portable measurement system consisting of a personal computer used as a Fourier analyzer and three detection channels (with associated electronics that provide the signals to analog-to-digital (A/D) convertors) has been assembled to measure subcriticality by the /sup 252/Cf-source-driven neutron noise analysis method. The /sup 252/Cf-source-driven neutron noise analysis method for obtaining the subcritical neutron multiplication factor of a configuration of fissile material requires measurement of the frequency-dependent cross-power spectral density (CPSD), G/sub 23/(ω), between a pair of detectors (Nos. 2 and 3) located in or near the fissile material and CPSDs G/sub 12/(ω) and G/sub 13/(ω) between these same detectors and a source of neutrons emanating from an ionization chamber (No. 1) containing /sup 252/Cf, also positioned in or near the fissile material. The auto-power spectral density (APSD), G/sub 11/(ω), of the source is also required. A particular ratio of spectral densities, G/sub 12//sup */G/sub 13//G/sub 11/G/sub 23/ (/sup */ denotes complex conjugation), is then formed. This ratio is related to the subcritical neutron multiplication factor and is independent of detector efficiencies

  3. A 6.13MeV gamma reference source, measurement of the emission rate

    International Nuclear Information System (INIS)

    Robert, Andre; Blondel, Maurice; Morel, Jean; Thomas, Claude.

    1977-08-01

    A 6.13MeV γ reference source has been produced by using 13 C(α, nγ) 16 O reaction occurring in an intimate 13 C and 238 Pu mixture. With two walls made leak proof this standard source is easy handled and convenient to the calibration of detectors. The 6.13MeV gamma ray is emitted without Doeppler effect, is measured with an uncertainty of 6% by three independent methods [fr

  4. Design of γ measurement system of neutron source strength standard with a manganese sulphate bath method

    International Nuclear Information System (INIS)

    Wang Xiaoqiong; Wang Pan; Chen Mingchi; Zhang Hui

    2010-01-01

    It mostly introduced the hardware and software design and test of Measurement System of Neutron Source Strength Standard with a Manganese Sulphate Bath Method. Hardware of system mainly contains six modules named detector, high voltage source, head amplifier, main amplifier, single channel pulse-amplitude analyzer and data acquisition system. The software program of system data acquisition is made up of four functional modules: user login, parameter setting, data collection, and data saving. (authors)

  5. Source profiles of volatile organic compounds (VOCs) measured in China: Part I

    Science.gov (United States)

    Liu, Ying; Shao, Min; Fu, Linlin; Lu, Sihua; Zeng, Limin; Tang, Dagang

    The profiles of major volatile organic compound (VOC) sources in China, including vehicle exhaust, gasoline vapor, paint, asphalt, industrial and residential coal burning, biomass burning, and the petrochemical industry, were experimentally determined. Source samples were taken using a dilution chamber for mobile and stationary sources, biomass burning in an actual Chinese farmer's house, and ambient air in a petrochemical industrial area. The concentrations of 92 VOC species were quantified using canister sampling and a gas chromatography-flame ionization detection/mass spectrometry system, and VOC source profiles were developed for source apportionment of VOCs in the Pearl River Delta region. Based on the measurement of source profiles, possible tracers for various emission sources were identified; e.g., 2-methylpentane and 1,3-butadiene could be used as tracers for vehicle exhaust; the characteristic compounds of architectural coating were aromatics such as toluene and m, p-xylene; the light hydrocarbons, namely n-butane, trans-2-butene, and n-pentane, dominated the composition of gasoline vapor; and n-nonane, n-decane, and n-undecane were found to be typical of diesel vapor and asphalt application processes. As different emission sources are characterized by overlapping VOC species, the ratio of possible VOC tracers could be used to assess the contribution of various sources. The ratios between n-butane and isobutane, 1,3-butadiene and isoprene, and the ratios of aromatics (e.g., toluene to benzene and ethylbenzene to m, p-xylene) in the measured sources were compared.

  6. Source modelling of train noise - Literature review and some initial measurements

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Xuetao; Jonasson, Hans; Holmberg, Kjell

    2000-07-01

    A literature review of source modelling of railway noise is reported. Measurements on a special test rig at Surahammar and on the new railway line between Arlanda and Stockholm City are reported and analyzed. In the analysis the train is modelled as a number of point sources with or without directivity and each source is combined with analytical sound propagation theory to predict the sound propagation pattern best fitting the measured data. Wheel/rail rolling noise is considered to be the most important noise source. The rolling noise can be modelled as an array of moving point sources, which have a dipole-like horizontal directivity and some kind of vertical directivity. In general it is necessary to distribute the point sources on several heights. Based on our model analysis the source heights for the rolling noise should be below the wheel axles and the most important height is about a quarter of wheel diameter above the railheads. When train speeds are greater than 250 km/h aerodynamic noise will become important and even dominant. It may be important for low frequency components only if the train speed is less than 220 km/h. Little data are available for these cases. It is believed that aerodynamic noise has dipole-like directivity. Its spectrum depends on many factors: speed, railway system, type of train, bogies, wheels, pantograph, presence of barriers and even weather conditions. Other sources such as fans, engine, transmission and carriage bodies are at most second order noise sources, but for trains with a diesel locomotive engine the engine noise will be dominant if train speeds are less than about 100 km/h. The Nord 2000 comprehensive model for sound propagation outdoors, together with the source model that is based on the understandings above, can suitably handle the problems of railway noise propagation in one-third octave bands although there are still problems left to be solved.

  7. Broadband light source for fiber-optic measurement system in spaceborne applications

    Science.gov (United States)

    Rößner, Max R.; Müller, Mathias S.; Buck, Thorbjörn C.; Koch, Alexander W.

    2012-01-01

    Measuring temperatures, mechanical loads and derived quantities precisely and reliably play an important role in spaceflight. With spacecraft becoming increasingly complex, upscaling of present telemetry techniques can become cumbersome. Additionally, there are entirely new sensory requirements, resulting from emerging technologies such as smart structures, active vibration damping and composite material health monitoring. It has been demonstrated in preceding studies that these measurements can be advantageously and efficiently carried out by means of fiber-optic systems. The most prominent fiber-optic strain and temperature sensor is the fiber Bragg grating. Typically, multiple fiber Bragg gratings are used to translate entire temperature and strain fields into an optical wavelength information. For the interrogation of these sensors, a broadband or scanning light source is required. Additional requirements with respect to the light source are high intensity and unpolarized illumination of the gratings. These constraints can be met by a light source that is based on amplified spontaneous emission in a rare-earth-doped fiber. In the presented work, a compact light source, adapted for measurement applications and targeted towards space applications, has been developed. The design of this light source is presented, as well as its implementation. The light source has been designed and tested for selected core aspects of space robustness and the results of these tests are summarized.

  8. Determination of noise sources and space-dependent reactor transfer functions from measured output signals only

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, J.E.; van Dam, H.; Kleiss, E.B.J.; van Uitert, G.C.; Veldhuis, D.

    1982-01-01

    The measured cross power spectral densities of the signals from three neutron detectors and the displacement of the control rod of the 2 MW research reactor HOR at Delft have been used to determine the space-dependent reactor transfer function, the transfer function of the automatic reactor control system and the noise sources influencing the measured signals. From a block diagram of the reactor with control system and noise sources expressions were derived for the measured cross power spectral densities, which were adjusted to satisfy the requirements following from the adopted model. Then for each frequency point the required transfer functions and noise sources could be derived. The results are in agreement with those of autoregressive modelling of the reactor control feed-back loop. A method has been developed to determine the non-linear characteristics of the automatic reactor control system by analysing the non-gaussian probability density function of the power fluctuations.

  9. Determination of noise sources and space-dependent reactor transfer functions from measured output signals only

    International Nuclear Information System (INIS)

    Hoogenboom, J.E.

    1982-01-01

    The measured cross power spectral densities of the signals from three neutron detectors and the displacement of the control rod of the 2 MW research reactor HOR at Delft have been used to determine the space-dependent reactor transfer function, the transfer function of the automatic reactor control system and the noise sources influencing the measured signals. From a block diagram of the reactor with control system and noise sources expressions were derived for the measured cross power spectral densities, which were adjusted to satisfy the requirements following from the adopted model. Then for each frequency point the required transfer functions and noise sources could be derived. The results are in agreement with those of autoregressive modelling of the reactor control feed-back loop. A method has been developed to determine the non-linear characteristics of the automatic reactor control system by analysing the non-gaussian probability density function of the power fluctuations. (author)

  10. Analysis of rod drop and pulsed source measurements of reactivity in the Winfrith SGHWR

    International Nuclear Information System (INIS)

    Brittain, I.

    1970-05-01

    Reactivity measurements by the rod-drop and pulsed source methods in the Winfrith SGHWR are seriously affected by spatial harmonics. A method of calculation is described which enables the spatial harmonics to be calculated in non-uniform cores in two or three dimensions, and thus allows a much more rigorous analysis of the experimental results than the usual point model. The method is used to analyse all the rod-drop measurements made during commissioning of the Winfrith SGHWR, and to comment on the results of pulsed source measurements. The reactivity worths of banks of ten and twelve shut-down tubes deduced from rod-drop and pulsed source experiments are in satisfactory agreement with each other and also with AIMAZ calculated values. The ability to calculate higher spatial harmonics in nonuniform cores is thought to be new, and may have a wider application to reactor kinetics through the method of Modal Analysis. (author)

  11. Measurement and simulation of the time-dependent behavior of the UMER source

    International Nuclear Information System (INIS)

    Haber, I.; Feldman, D.; Fiorito, R.; Friedman, A.; Grote, D.P.; Kishek, R.A.; Quinn, B.; Reiser, M.; Rodgers, J.; O'Shea, P.G.; Stratakis, D.; Tian, K.; Vay, J.-L.; Walter, M.

    2007-01-01

    Control of the time-dependent characteristics of the beam pulse, beginning when it is born from the source, is important for obtaining adequate beam intensity on a target. Recent experimental measurements combined with the new mesh-refinement capability in WARP have improved the understanding of time-dependent beam characteristics beginning at the source, as well as the predictive ability of the simulation codes. The University of Maryland Electron Ring (UMER), because of its ease of operation and flexible diagnostics has proved particularly useful for benchmarking WARP by comparing simulation to measurement. One source of significant agreement has been in the ability of three-dimensional WARP simulations to predict the onset of virtual cathode oscillations in the vicinity of the cathode grid in the UMER gun, and the subsequent measurement of the predicted oscillations

  12. Determination of delayed neutrons source in the frequency domain based on in-pile oscillation measurements

    International Nuclear Information System (INIS)

    Yedvab, Y.; Reiss, I.; Bettan, M.; Harari, R.; Grober, A.; Ettedgui, H.; Caspi, E. N.

    2006-01-01

    A method for determining delayed neutrons source in the frequency domain based on measuring power oscillations in a non-critical reactor is presented. This method is unique in the sense that the delayed neutrons source is derived from the dynamic behavior of the reactor, which serves as the measurement system. An algorithm for analyzing power oscillation measurements was formulated, which avoids the need for a multi-parameter non-linear fit process used by other methods. Using this algorithm results of two sets of measurements performed in IRR-I and IRR-II (Israeli Research Reactors I and II) are presented. The agreement between measured values from both reactors and calculated values based on Keepin (and JENDL-3.3) group parameters is very good. (authors)

  13. Corrections to air kerma rate measurements of 125I brachytherapy sources to free space conditions

    International Nuclear Information System (INIS)

    Shipley, D.R.; Duane, S.

    1994-05-01

    Air kerma rate measurements have been made between 40 cm and 100 cm from one of a set of 125 I reference sources within the facilities of Amersham International plc. Monte Carlo techniques have been used to calculate the air kerma rate components over the same range of distances from this source. After comparing the calculated data with measurements, the compliance of the data with the inverse square law was investigated, and corrections were derived to obtain the air kerma rate at 1 m in free space from each source. Simulations of the experimental setup with an isotropic monoenergetic point source close to the effective energy of 125 I were found to reproduce the air kerma rate measurements reasonably accurately, and indicated that the contribution due to scattered photons was significant. The overall correction (which is defined as the product of individual corrections for chamber size effect, air attenuation and radiation scatter) required to the inverse square law to obtain the air kerma rate at 1 m in free space was found to be 0.981, 0.984 and 0.980, respectively, for air kerma rate measurements at 40 cm, 60 cm and 100 cm from the 125 I reference source. The total uncertainty in these corrections was estimated to be 0.88% at the 1σ level. (author)

  14. Sub-micrometre accurate free-form optics by three-dimensional printing on single-mode fibres

    Science.gov (United States)

    Gissibl, Timo; Thiele, Simon; Herkommer, Alois; Giessen, Harald

    2016-01-01

    Micro-optics are widely used in numerous applications, such as beam shaping, collimation, focusing and imaging. We use femtosecond 3D printing to manufacture free-form micro-optical elements. Our method gives sub-micrometre accuracy so that direct manufacturing even on single-mode fibres is possible. We demonstrate the potential of our method by writing different collimation optics, toric lenses, free-form surfaces with polynomials of up to 10th order for intensity beam shaping, as well as chiral photonic crystals for circular polarization filtering, all aligned onto the core of the single-mode fibres. We determine the accuracy of our optics by analysing the output patterns as well as interferometrically characterizing the surfaces. We find excellent agreement with numerical calculations. 3D printing of microoptics can achieve sufficient performance that will allow for rapid prototyping and production of beam-shaping and imaging devices. PMID:27339700

  15. Neutron total cross section measurements of gold and tantalum at the nELBE photoneutron source

    CERN Document Server

    Hannaske, Roland; Beyer, Roland; Junghans, Arnd; Bemmerer, Daniel; Birgersson, Evert; Ferrari, Anna; Grosse, Eckart; Kempe, Mathias; Kögler, Toni; Marta, Michele; Massarczyk, Ralph; Matic, Andrija; Schramm, Georg; Schwengner, Ronald; Wagner, Andreas

    2014-01-01

    Neutron total cross sections of 197 Au and nat Ta have been measured at the nELBE photoneutron source in the energy range from 0.1 - 10 MeV with a statistical uncertainty of up to 2 % and a total systematic uncertainty of 1 %. This facility is optimized for the fast neutron energy range and combines an excellent t ime structure of the neutron pulses (electron bunch width 5 ps) with a short flight path of 7 m. Because of the low instantaneous neutron flux transmission measurements of neutron total cross sections are possible, that exhibit very different beam and back ground conditions than found at other neutron sources.

  16. Orphan Sources and Fresh Fallout: Virtual Exercise in Mobile Measurement (ORPEX)

    Energy Technology Data Exchange (ETDEWEB)

    Dowdall, M. (Norwegian Radiation Protection Authority, OEsteraas (Norway)); Smethurst, M.A. (Univ. of Exeter and Avalonia Geophysics, Cornwall Campus, Penryn (United Kingdom)); Andersson, K. (Technical Univ. of Denmark. Risoe National Lab. for Sustainable Energy, Roskilde (Denmark)); Aage, H.K. (Danish Emergency Management Agency, Birkeroed (Denmark)); Palsson, S.E. (Icelandic Radiation Protection Institute, Reykjavik (Iceland))

    2011-10-15

    In recent years carborne gamma spectrometry has expanded from its role as a geological survey platform to serving as a useful asset in the field of emergency response to radiological and nuclear situations. Its two main applications are searching for orphan sources and for surveying in the aftermath of an accident involving the release of radioactive materials. Despite this expansion, the opportunities for gaining practical experience in the field are limited by cost considerations and practicability. These limitations are exacerbated by the fact that data generated and displayed in the field differ significantly from gamma spectral data generated in a laboratory environment. As a means of exercising existing emergency measuring/surveying capability and introducing carborne measurements to a larger group, a virtual exercise was devised. The exercise ORPEX (Orphan Sources and Fresh Fallout Virtual Exercise in Mobile Measurement) featured two typical emergency scenarios in which carborne measuring systems might be deployed: firstly a search for multiple orphan sources and secondly surveying to delineate patchy fallout from a local release point. In the first scenario, synthetic spectral data were generated for imaginary point sources and inserted into genuine carborne measurements from in the Trondheim area of Norway. Participants were presented with a typical software tool and data in a range of typical formats and asked to report the source locations and isotopes within a time limit. In the second scenario, synthetic spectral data representing fallout from a local fire involving radioactive material were added to real carborne data from the Trondheim area. Participants were asked to produce maps that identify and characterise the regions of contamination within the same time limit. Fourteen individual organisations from seven different countries supplied results. Results from participants indicate that for strong sources of isotopes with simple spectra featuring

  17. Orphan Sources and Fresh Fallout: Virtual Exercise in Mobile Measurement (ORPEX)

    International Nuclear Information System (INIS)

    Dowdall, M.; Smethurst, M.A.; Andersson, K.; Aage, H.K.; Palsson, S.E.

    2011-10-01

    In recent years carborne gamma spectrometry has expanded from its role as a geological survey platform to serving as a useful asset in the field of emergency response to radiological and nuclear situations. Its two main applications are searching for orphan sources and for surveying in the aftermath of an accident involving the release of radioactive materials. Despite this expansion, the opportunities for gaining practical experience in the field are limited by cost considerations and practicability. These limitations are exacerbated by the fact that data generated and displayed in the field differ significantly from gamma spectral data generated in a laboratory environment. As a means of exercising existing emergency measuring/surveying capability and introducing carborne measurements to a larger group, a virtual exercise was devised. The exercise ORPEX (Orphan Sources and Fresh Fallout Virtual Exercise in Mobile Measurement) featured two typical emergency scenarios in which carborne measuring systems might be deployed: firstly a search for multiple orphan sources and secondly surveying to delineate patchy fallout from a local release point. In the first scenario, synthetic spectral data were generated for imaginary point sources and inserted into genuine carborne measurements from in the Trondheim area of Norway. Participants were presented with a typical software tool and data in a range of typical formats and asked to report the source locations and isotopes within a time limit. In the second scenario, synthetic spectral data representing fallout from a local fire involving radioactive material were added to real carborne data from the Trondheim area. Participants were asked to produce maps that identify and characterise the regions of contamination within the same time limit. Fourteen individual organisations from seven different countries supplied results. Results from participants indicate that for strong sources of isotopes with simple spectra featuring

  18. Radio weak lensing shear measurement in the visibility domain - II. Source extraction

    Science.gov (United States)

    Rivi, M.; Miller, L.

    2018-05-01

    This paper extends the method introduced in Rivi et al. (2016b) to measure galaxy ellipticities in the visibility domain for radio weak lensing surveys. In that paper, we focused on the development and testing of the method for the simple case of individual galaxies located at the phase centre, and proposed to extend it to the realistic case of many sources in the field of view by isolating visibilities of each source with a faceting technique. In this second paper, we present a detailed algorithm for source extraction in the visibility domain and show its effectiveness as a function of the source number density by running simulations of SKA1-MID observations in the band 950-1150 MHz and comparing original and measured values of galaxies' ellipticities. Shear measurements from a realistic population of 104 galaxies randomly located in a field of view of 1 \\deg ^2 (i.e. the source density expected for the current radio weak lensing survey proposal with SKA1) are also performed. At SNR ≥ 10, the multiplicative bias is only a factor 1.5 worse than what found when analysing individual sources, and is still comparable to the bias values reported for similar measurement methods at optical wavelengths. The additive bias is unchanged from the case of individual sources, but it is significantly larger than typically found in optical surveys. This bias depends on the shape of the uv coverage and we suggest that a uv-plane weighting scheme to produce a more isotropic shape could reduce and control additive bias.

  19. The differential Howland current source with high signal to noise ratio for bioimpedance measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jinzhen; Li, Gang; Lin, Ling, E-mail: linling@tju.edu.cn [State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, People' s Republic of China, and Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin University, Tianjin (China); Qiao, Xiaoyan [College of Physics and Electronic Engineering, Shanxi University, Shanxi (China); Wang, Mengjun [School of Information Engineering, Hebei University of Technology, Tianjin (China); Zhang, Weibo [Institute of Acupuncture and Moxibustion China Academy of Chinese Medical Sciences, Beijing (China)

    2014-05-15

    The stability and signal to noise ratio (SNR) of the current source circuit are the important factors contributing to enhance the accuracy and sensitivity in bioimpedance measurement system. In this paper we propose a new differential Howland topology current source and evaluate its output characters by simulation and actual measurement. The results include (1) the output current and impedance in high frequencies are stabilized after compensation methods. And the stability of output current in the differential current source circuit (DCSC) is 0.2%. (2) The output impedance of two current circuits below the frequency of 200 KHz is above 1 MΩ, and below 1 MHz the output impedance can arrive to 200 KΩ. Then in total the output impedance of the DCSC is higher than that of the Howland current source circuit (HCSC). (3) The SNR of the DCSC are 85.64 dB and 65 dB in the simulation and actual measurement with 10 KHz, which illustrates that the DCSC effectively eliminates the common mode interference. (4) The maximum load in the DCSC is twice as much as that of the HCSC. Lastly a two-dimensional phantom electrical impedance tomography is well reconstructed with the proposed HCSC. Therefore, the measured performance shows that the DCSC can significantly improve the output impedance, the stability, the maximum load, and the SNR of the measurement system.

  20. E-line: A new crystal collimator beam line for source size measurements at CHESS

    Energy Technology Data Exchange (ETDEWEB)

    White, Jeffrey A. [CHESS, Cornell High Energy Synchrotron Source, Cornell University, Ithaca, NY 14850-8001 (United States)], E-mail: jaw7@cornell.edu; Revesz, Peter; Finkelstein, Ken [CHESS, Cornell High Energy Synchrotron Source, Cornell University, Ithaca, NY 14850-8001 (United States)

    2007-11-11

    A new X-ray beam line has been constructed at cornell high energy synchrotron source (CHESS) to measure the vertical and horizontal source size of the positron particle beam. The cornell laboratory of elementary particle physics (LEPP) operates the storage ring (CESR) for X-ray generation for the CHESS user community by circulating electrons and their antimatter counterpart positrons in counter-rotating beams. As the laboratory reduces the emittances of particle beams to increase X-ray brilliance, there has been an increasing need for diagnostic tools to measure and monitor source size. A beam line front end that accesses the positron synchrotron light has been fitted with an experimental chamber and apparatus of compact design capable of horizontal and vertical source size measurement using the 'crystal collimator' technique, and an additional setup for vertical beam position monitoring using a luminescence-based X-ray video beam position monitoring system. The crystal collimators each consist of two Si(2 2 0) crystals in a dispersive (+,+) arrangement that diffract X-rays to a fluorescent material coated on a view port observed with a CCD camera. Measurements of the positron vertical beam size using the crystal collimation method at E-line are compared with measurements of visible synchrotron light at a remotely located dedicated port on the storage ring.

  1. E-line: A new crystal collimator beam line for source size measurements at CHESS

    International Nuclear Information System (INIS)

    White, Jeffrey A.; Revesz, Peter; Finkelstein, Ken

    2007-01-01

    A new X-ray beam line has been constructed at cornell high energy synchrotron source (CHESS) to measure the vertical and horizontal source size of the positron particle beam. The cornell laboratory of elementary particle physics (LEPP) operates the storage ring (CESR) for X-ray generation for the CHESS user community by circulating electrons and their antimatter counterpart positrons in counter-rotating beams. As the laboratory reduces the emittances of particle beams to increase X-ray brilliance, there has been an increasing need for diagnostic tools to measure and monitor source size. A beam line front end that accesses the positron synchrotron light has been fitted with an experimental chamber and apparatus of compact design capable of horizontal and vertical source size measurement using the 'crystal collimator' technique, and an additional setup for vertical beam position monitoring using a luminescence-based X-ray video beam position monitoring system. The crystal collimators each consist of two Si(2 2 0) crystals in a dispersive (+,+) arrangement that diffract X-rays to a fluorescent material coated on a view port observed with a CCD camera. Measurements of the positron vertical beam size using the crystal collimation method at E-line are compared with measurements of visible synchrotron light at a remotely located dedicated port on the storage ring

  2. Validating criticality calculations for spent fuel with 252Cf-source-driven noise measurements

    International Nuclear Information System (INIS)

    Mihalczo, J.T.; Krass, A.W.; Valentine, T.E.

    1992-01-01

    The 252 Cf-Source-driven noise analysis method can be used for measuring the subcritical neutron multiplication factor k of arrays of spent light water reactor (LWR) fuel. This type of measurement provides a parameter that is directly related to the criticality state of arrays of LWR fuel. Measurements of this parameter can verify the criticality safety margins of spent LWR fuel configurations and thus could be a means of obtaining the information to justify burnup credit for spent LWR transportation/storage casks. The practicality of a measurement depends on the ability to install the hardware required to perform the measurement. Source chambers containing the 252 Cf at the required source intensity for this application have been constructed and have operated successfully for ∼10 years and can be fabricated to fit into control rod guide tubes of PWR fuel elements. Fission counters especially developed for spent-fuel measurements are available that would allow measurements of a special 3 x 3 spent fuel array and a typical burnup credit rail cask with spent fuel in unborated water. Adding a moderator around these fission counters would allow measurements with the typical burnup credit rail cask with borated water and the special 3 x 3 array with borated water. The recent work of Ficaro on modifying the KENO Va code to calculate by the Monte Carlo method the time sequences of pulses at two detectors near a fissile assembly from the fission chain multiplication process, initiated by a 252 Cf source in the assembly allows a direct computer calculation of the noise analysis data from this measurement method

  3. A new mini-extrapolation chamber for beta source uniformity measurements

    International Nuclear Information System (INIS)

    Oliveira, M.L.; Caldas, L.V.E.

    2006-01-01

    According to recent international recommendations, beta particle sources should be specified in terms of absorbed dose rates to water at the reference point. However, because of the clinical use of these sources, additional information should be supplied in the calibration reports. This additional information include the source uniformity. A new small volume extrapolation chamber was designed and constructed at the Calibration Laboratory at Instituto de Pesquisas Energeticas e Nucleares, IPEN, Brazil, for the calibration of 90 Sr+ 90 Y ophthalmic plaques. This chamber can be used as a primary standard for the calibration of this type of source. Recent additional studies showed the feasibility of the utilization of this chamber to perform source uniformity measurements. Because of the small effective electrode area, it is possible to perform independent measurements by varying the chamber position by small steps. The aim of the present work was to study the uniformity of a 90 Sr+ 90 Y plane ophthalmic plaque utilizing the mini extrapolation chamber developed at IPEN. The uniformity measurements were performed by varying the chamber position by steps of 2 mm in the source central axis (x-and y-directions) and by varying the chamber position off-axis by 3 mm steps. The results obtained showed that this small volume chamber can be used for this purpose with a great advantage: it is a direct method, being unnecessary a previously calibration of the measurement device in relation to a reference instrument, and it provides real -time results, reducing the time necessary for the study and the determination of the uncertainties related to the measurements. (authors)

  4. Monte Carlo calculations and experimental measurements of dosimetric parameters of the IRA-103Pd brachytherapy source

    International Nuclear Information System (INIS)

    Sadeghi, Mahdi; Raisali, Gholamreza; Hosseini, S. Hamed; Shavar, Arzhang

    2008-01-01

    This article presents a brachytherapy source having 103 Pd adsorbed onto a cylindrical silver rod that has been developed by the Agricultural, Medical, and Industrial Research School for permanent implant applications. Dosimetric characteristics (radial dose function, anisotropy function, and anisotropy factor) of this source were experimentally and theoretically determined in terms of the updated AAPM Task group 43 (TG-43U1) recommendations. Monte Carlo simulations were used to calculate the dose rate constant. Measurements were performed using TLD-GR200A circular chip dosimeters using standard methods employing thermoluminescent dosimeters in a Perspex phantom. Precision machined bores in the phantom located the dosimeters and the source in a reproducible fixed geometry, providing for transverse-axis and angular dose profiles over a range of distances from 0.5 to 5 cm. The Monte Carlo N-particle (MCNP) code, version 4C simulation techniques have been used to evaluate the dose-rate distributions around this model 103 Pd source in water and Perspex phantoms. The Monte Carlo calculated dose rate constant of the IRA- 103 Pd source in water was found to be 0.678 cGy h -1 U -1 with an approximate uncertainty of ±0.1%. The anisotropy function, F(r,θ), and the radial dose function, g(r), of the IRA- 103 Pd source were also measured in a Perspex phantom and calculated in both Perspex and liquid water phantoms

  5. Measurement of electron beams profile of pierce type electron source using sensor of used Tv tube

    International Nuclear Information System (INIS)

    Darsono; Suhartono; Suprapto; Elin Nuraini

    2015-01-01

    The measurement of an electron beam profile has been performed using electron beam monitor based on method of phosphorescent materials. The main components of the electron beam monitor consists of a fluorescent sensor using a used Tv tube, CCTV camera to record images on a Tv screen, video adapter as interface between CCTV and laptop, and the laptop as a viewer and data processing. Two Pierce-type electron sources diode and triode was measured the shape of electron beam profile in real time. Results of the experiments showed that the triode electron source of Pierce type gave the shape of electron beam profiles better than that of the diode electron source .The anode voltage is not so influential on the beam profile shape. The focused voltage in the triode electron source is so influence to the shape of the electron beam profile, but above 5 kV no great effect. It can be concluded that the electron beam monitor can provide real time observations and drawings shape of the electron beam profile displayed on the used Tv tube glass screen which is the real picture of the shape of the electron beam profile. Triode electron source produces a better electron beam profile than that of the diode electron source. (author)

  6. Measurement of electron emission due to energetic ion bombardment in plasma source ion implantation

    Science.gov (United States)

    Shamim, M. M.; Scheuer, J. T.; Fetherston, R. P.; Conrad, J. R.

    1991-11-01

    An experimental procedure has been developed to measure electron emission due to energetic ion bombardment during plasma source ion implantation. Spherical targets of copper, stainless steel, graphite, titanium alloy, and aluminum alloy were biased negatively to 20, 30, and 40 kV in argon and nitrogen plasmas. A Langmuir probe was used to detect the propagating sheath edge and a Rogowski transformer was used to measure the current to the target. The measurements of electron emission coefficients compare well with those measured under similar conditions.

  7. Measurements on Pb27+ Sources for the CERN Heavy Ion Injection Chain

    CERN Document Server

    Chamings, J A

    2004-01-01

    CERN, the world's largest particle physics laboratory near Geneva, is currently in the process of building the Large Hadron Collider (LHC). Lead-208 will be used in this accelerator and to meet the injection requirements much work is required to find a suitable and reliable heavy ion source. The work in this report covers two ion sources, the Laser Ion Source (LIS), and the Electron Cyclotron Resonance Ion Source (ECRIS). An emittance measurement, using a pepper pot and CCD camera, was completed on the recently re-installed LIS, measured and analysed to be 140mm.mrad un-normalised and 0.8mm.mrad normalised 4rms for the maximum intensity charge state, Pb27+. A Visual Basic Program was modified to allow Charge State Distribution (CSD) and other scans of the ECRIS at CERN to be taken. Chapter 5 presents the results of the CSD scans taken. This program provided a new method to take 1 dimensional transverse beam profiles. From this a direct emittance measurement was formed for the first time since the source was o...

  8. Advances in Mineral Dust Source Composition Measurement with Imaging Spectroscopy at the Salton Sea, CA

    Science.gov (United States)

    Green, R. O.; Realmuto, V. J.; Thompson, D. R.; Mahowald, N. M.; Pérez García-Pando, C.; Miller, R. L.; Clark, R. N.; Swayze, G. A.; Okin, G. S.

    2015-12-01

    Mineral dust emitted from the Earth's surface is a principal contributor to direct radiative forcing over the arid regions, where shifts in climate have a significant impact on agriculture, precipitation, and desert encroachment around the globe. Dust particles contribute to both positive and negative forcing, depending on the composition of the particles. Particle composition is a function of the surface mineralogy of dust source regions, but poor knowledge of surface mineralogy on regional to global scales limits the skill of Earth System models to predict shifts in regional climate around the globe. Earth System models include the source, emission, transport and deposition phases of the dust cycle. In addition to direct radiative forcing contributions, mineral dust impacts include indirect radiative forcing, modification of the albedo and melting rates of snow and ice, kinetics of tropospheric photochemistry, formation and deposition of acidic aerosols, supply of nutrients to aquatic and terrestrial ecosystems, and impact on human health and safety. We demonstrate the ability to map mineral dust source composition in the Salton Sea dust source region with imaging spectroscopy measurements acquired as part of the NASA HyspIRI preparatory airborne campaign. These new spectroscopically derived compositional measurements provide a six orders of magnitude improvement over current atlases for this dust source region and provide a pathfinder example for a remote measurement approach to address this critical dust composition gap for global Earth System models.

  9. Radioactivity determination of sealed pure beta-sources by surface dose measurements and Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Seongmoon [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Choi, Kanghyuk; Son, Kwang-Jae; Lee, Jun Sig [Hanaro Applications Research, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ye, Sung-Joon, E-mail: sye@snu.ac.kr [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Center for Convergence Research on Robotics, Advance Institutes of Convergence Technology, Seoul National University, Suwon (Korea, Republic of)

    2016-04-21

    This study aims to determine the activity of a sealed pure beta-source by measuring the surface dose rate using an extrapolation chamber. A conversion factor (cGy s{sup −1} Bq{sup −1}), which was defined as the ratio of surface dose rate to activity, can be calculated by Monte Carlo simulations of the extrapolation chamber measurement. To validate this hypothesis the certified activities of two standard pure beta-sources of Sr/Y-90 and Si/P-32 were compared with those determined by this method. In addition, a sealed test source of Sr/Y-90 was manufactured by the HANARO reactor group of KAERI (Korea Atomic Energy Research Institute) and used to further validate this method. The measured surface dose rates of the Sr/Y-90 and Si/P-32 standard sources were 4.615×10{sup −5} cGy s{sup −1} and 2.259×10{sup −5} cGy s{sup −1}, respectively. The calculated conversion factors of the two sources were 1.213×10{sup −8} cGy s{sup −1} Bq{sup −1} and 1.071×10{sup −8} cGy s{sup −1} Bq{sup −1}, respectively. Therefore, the activity of the standard Sr/Y-90 source was determined to be 3.995 kBq, which was 2.0% less than the certified value (4.077 kBq). For Si/P-32 the determined activity was 2.102 kBq, which was 6.6% larger than the certified activity (1.971 kBq). The activity of the Sr/Y-90 test source was determined to be 4.166 kBq, while the apparent activity reported by KAERI was 5.803 kBq. This large difference might be due to evaporation and diffusion of the source liquid during preparation and uncertainty in the amount of weighed aliquot of source liquid. The overall uncertainty involved in this method was determined to be 7.3%. We demonstrated that the activity of a sealed pure beta-source could be conveniently determined by complementary combination of measuring the surface dose rate and Monte Carlo simulations.

  10. The inductively coupled plasma as a source for the measurement of fundamental spectroscopic constants

    International Nuclear Information System (INIS)

    Farnsworth, P.B.

    1993-01-01

    Inductively coupled plasmas (ICPs) are stable, robust sources for the generation of spectra from neutral and singly ionized atoms. They are used extensively for analytical spectrometry, but have seen limited use for the measurement of fundamental spectroscopic constants. Several properties of the ICP affect its suitability for such fundamental measurements. They include: spatial structure, spectral background, noise characteristics, electron densities and temperatures, and the state of equilibrium in the plasma. These properties are particularly sensitive to the means by which foreign atoms are introduced into the plasma. With some departures from the operating procedures normally used in analytical measurements, the ICP promise to be a useful source for the measurement of fundamental atomic constants. (orig.)

  11. Orphan Sources and Fresh Fallout: Virtual Exercise in Mobile Measurement (ORPEX)

    DEFF Research Database (Denmark)

    Dowdall, M.; Smethurst, M.A.; Andersson, Kasper Grann

    In recent years carborne gamma spectrometry has expanded from its role as a geological survey platform to serving as a useful asset in the field of emergency response to radiological and nuclear situations. Its two main applications are searching for orphan sources and for surveying in the afterm......In recent years carborne gamma spectrometry has expanded from its role as a geological survey platform to serving as a useful asset in the field of emergency response to radiological and nuclear situations. Its two main applications are searching for orphan sources and for surveying...... spectral data were generated for imaginary point sources and inserted into genu-ine carborne measurements from in the Trondheim area of Norway. Participants were presented with a typical software tool and data in a range of typical formats and asked to report the source locations and isotopes within a time...

  12. Source-to-detector distance and beam center do not affect radiographic measurements of acetabular morphology

    International Nuclear Information System (INIS)

    Goldman, Ashton H.; Hoover, Kevin B.

    2017-01-01

    Multiple radiographic acquisition techniques have been evaluated for their effect on measurements of acetabular morphology. This cadaveric study examined the effect of two acquisition parameters not previously evaluated: beam center position and source-to-detector distance. This study also evaluated the effect of reader differences on measurements. Following calibration of measurements between two readers using five clinical radiographs (training), radiographs were obtained from two cadavers using four different source-to-detector distances and three different radiographic centers for a total of 12 radiographic techniques (experimental). Two physician readers acquired four types of measurements from each cadaver radiograph: lateral center edge angle, peak-to-edge distance, Sharp's angle, and the Tonnis angle. All measurements were evaluated for intra-class correlation coefficient (ICC), kappa statistics for hip dysplasia, and factors that resulted in measurement differences using a mixed statistical model. After training of the two physician readers, there was strong agreement in their hip morphology measurements (ICC 0.84-0.93), agreement in the presence of hip dysplasia (κ = 0.58-1.0), and no measurement difference between physician readers (p = 0.12-1.0). Experimental cadaver measurements showed moderate-to-strong agreement of the readers (ICC 0.74-0.93) and complete agreement on dysplasia (κ = 1). After accounting for reader and radiographic technique, there was no difference in hip morphology measurements (p = 0.83-0.99). In this cadaveric study, measurements of hip morphology were not affected by varying source-to-detector distance or beam center. We conclude that these acquisition parameters are not likely to affect the diagnosis of hip dysplasia in a clinical setting. (orig.)

  13. Source-to-detector distance and beam center do not affect radiographic measurements of acetabular morphology

    Energy Technology Data Exchange (ETDEWEB)

    Goldman, Ashton H. [Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA (United States); Hoover, Kevin B. [Virginia Commonwealth University, Department of Radiology, 1250 E Marshall St. 3rd Floor, PO Box 980615, Richmond, VA (United States)

    2017-04-15

    Multiple radiographic acquisition techniques have been evaluated for their effect on measurements of acetabular morphology. This cadaveric study examined the effect of two acquisition parameters not previously evaluated: beam center position and source-to-detector distance. This study also evaluated the effect of reader differences on measurements. Following calibration of measurements between two readers using five clinical radiographs (training), radiographs were obtained from two cadavers using four different source-to-detector distances and three different radiographic centers for a total of 12 radiographic techniques (experimental). Two physician readers acquired four types of measurements from each cadaver radiograph: lateral center edge angle, peak-to-edge distance, Sharp's angle, and the Tonnis angle. All measurements were evaluated for intra-class correlation coefficient (ICC), kappa statistics for hip dysplasia, and factors that resulted in measurement differences using a mixed statistical model. After training of the two physician readers, there was strong agreement in their hip morphology measurements (ICC 0.84-0.93), agreement in the presence of hip dysplasia (κ = 0.58-1.0), and no measurement difference between physician readers (p = 0.12-1.0). Experimental cadaver measurements showed moderate-to-strong agreement of the readers (ICC 0.74-0.93) and complete agreement on dysplasia (κ = 1). After accounting for reader and radiographic technique, there was no difference in hip morphology measurements (p = 0.83-0.99). In this cadaveric study, measurements of hip morphology were not affected by varying source-to-detector distance or beam center. We conclude that these acquisition parameters are not likely to affect the diagnosis of hip dysplasia in a clinical setting. (orig.)

  14. Measurements of neutron intensity from liquid deuterium moderator of the cold neutron source of KUR

    International Nuclear Information System (INIS)

    Kawai, Takeshi; Ebisawa, Toru; Akiyoshi, Tsunekazu; Tasaki, Seiji

    1990-01-01

    The neutron spectra from the liquid deuterium moderator of the cold neutron source of KUR were measured by the time of flight (TOF) method similar to the previous measurements for the liquid hydrogen moderator. The cold neutron gain factor is found to be about 20 ∼ 28 times for the wavelength longer than 6 A. Cold neutron intensities from the liquid deuterium moderator and from the liquid hydrogen moderator are compared and discussed. (author)

  15. Measurement and diagnosis system for 1.2 MV repetitive pulsed power source

    International Nuclear Information System (INIS)

    Li Yawei; Deng Jianjun; Xie Min; Feng Zongming; Liu Yuntao; Ma Chenggang

    2010-01-01

    In order to analyze the discharge performance and improve the design of the power system, a set of measurement and diagnosis system for the 1.2 MV repetitive pulsed power source, which supplies the drive power for a high power microwave source, has been designed by studying the high-voltage, high-current testing technology, data acquisition, signal processing, fault diagnosis, virtual instruments and electromagnetic compatibility technology, etc. A resistive-capacitive divider and a Rogowski coil are adopted in measurement; ADLINK corporation's PXI chips are used in data acquisition; data transmission system, condition monitoring and data analysis are developed by LabVIEW. This system can realize on-line monitoring and data analysis for the repetitive pulsed power source. (authors)

  16. Size of nuclear sources from measurements of proton-proton correlations at small relative momentum

    International Nuclear Information System (INIS)

    Rebreyend, D.; Kox, S.; Merchez, F.; Noren, B.; Perrin, C.; Khelfaoui, B.; Gondrand, J.C.; Bondorf, J.P.

    1990-01-01

    This contribution will present recent measurements performed on light heavy ion reactions at intermediate energies. Nuclear source sizes were determined by measuring the correlation at small relative momentum, between two protons detected in the EMRIC set-up. This technique allows the determination of the extent of the emitting source by constructing a correlation function for the coincident protons and analyzing it in the framework of a final state interaction model. We found the apparent source size to be large compared to the dimension of the studied system and low sensitivity of the extracted radii as a function of the target mass and detection angle. We will show that simulations may be needed to fully estimate the correlation induced by detectors with small angular acceptance

  17. Elevated temperature characterization of electron beam freeform fabricated Ti–6Al–4V and dispersion strengthened Ti–8Al–1Er

    International Nuclear Information System (INIS)

    Bush, R.W.; Brice, C.A.

    2012-01-01

    Highlights: ► Electron beam freeform fabrication process. ► Ti–6Al–4V and rare-earth dispersion Ti alloy. ► Tensile, creep, and oxidation properties comparable to alloys made with conventional fabrication methods. ► Fabrication process allows use of rare-earth dispersion Ti alloy. - Abstract: Electron beam freeform fabrication is an additive manufacturing process that can be used to build fully dense, structural metallic parts directly from a three-dimensional computer model. This technique can replace conventional fabrication methods, such as forging or machining from plate, and enable significant cost, time, and tool savings. Additionally, this method enables the fabrication of alloys with novel compositions that are not well suited to production via ingot metallurgy processes. Ti–8Al–1Er is an experimental dispersion strengthened titanium alloy composition that requires rapid cooling to achieve optimal properties and thus is not amenable to ingot metallurgy production methods. Oxide dispersion strengthened alloys, such as Ti–8Al–1Er are known to have excellent thermal stability and improved high temperature properties. In this work, the room temperature tensile, elevated temperature tensile, creep properties and oxidation resistance of electron beam additive manufactured Ti–6Al–4V and Ti–8Al–1Er were measured and compared to those of laser beam additive manufactured Ti–8Al–1Er and wrought Ti–6Al–4V. Elevated temperature tensile properties were measured between 93° and 538 °C. Creep tests were performed between 425° and 455 °C at stresses between 345 and 483 MPa. It was found that the elevated temperature properties of the electron beam additive manufactured products are comparable to those of wrought forms. The elevated temperature strengths of Ti–8Al–1Er are comparable to those of Ti–6Al–4V in percentage of room temperature strength retained at temperature. Based on a Larson–Miller analysis of the creep test

  18. Elevated temperature characterization of electron beam freeform fabricated Ti-6Al-4V and dispersion strengthened Ti-8Al-1Er

    Energy Technology Data Exchange (ETDEWEB)

    Bush, R.W., E-mail: ralph.bush@usafa.edu [Department of Engineering Mechanics, 2354 Fairchild Dr., U.S. Air Force Academy, USAF Academy, CO 80840 (United States); Brice, C.A. [Lockheed Martin Aeronautics Co., Fort Worth, TX (United States)

    2012-09-30

    Highlights: Black-Right-Pointing-Pointer Electron beam freeform fabrication process. Black-Right-Pointing-Pointer Ti-6Al-4V and rare-earth dispersion Ti alloy. Black-Right-Pointing-Pointer Tensile, creep, and oxidation properties comparable to alloys made with conventional fabrication methods. Black-Right-Pointing-Pointer Fabrication process allows use of rare-earth dispersion Ti alloy. - Abstract: Electron beam freeform fabrication is an additive manufacturing process that can be used to build fully dense, structural metallic parts directly from a three-dimensional computer model. This technique can replace conventional fabrication methods, such as forging or machining from plate, and enable significant cost, time, and tool savings. Additionally, this method enables the fabrication of alloys with novel compositions that are not well suited to production via ingot metallurgy processes. Ti-8Al-1Er is an experimental dispersion strengthened titanium alloy composition that requires rapid cooling to achieve optimal properties and thus is not amenable to ingot metallurgy production methods. Oxide dispersion strengthened alloys, such as Ti-8Al-1Er are known to have excellent thermal stability and improved high temperature properties. In this work, the room temperature tensile, elevated temperature tensile, creep properties and oxidation resistance of electron beam additive manufactured Ti-6Al-4V and Ti-8Al-1Er were measured and compared to those of laser beam additive manufactured Ti-8Al-1Er and wrought Ti-6Al-4V. Elevated temperature tensile properties were measured between 93 Degree-Sign and 538 Degree-Sign C. Creep tests were performed between 425 Degree-Sign and 455 Degree-Sign C at stresses between 345 and 483 MPa. It was found that the elevated temperature properties of the electron beam additive manufactured products are comparable to those of wrought forms. The elevated temperature strengths of Ti-8Al-1Er are comparable to those of Ti-6Al-4V in percentage of room

  19. Bremsstrahlung and Ion Beam Current Measurements with SuSI ECR Ion Source

    International Nuclear Information System (INIS)

    Ropponen, T.

    2012-01-01

    This series of slides presents: the Superconducting Source for Ions (SuSI), the X-ray measurement setup, the different collimation schemes, the flat B operation versus B(min) operation, and the impact of tuning ∇B while keeping fixed field profile

  20. Exposition by inhalation to the formaldehyde in the air. Source, measures and concentrations

    International Nuclear Information System (INIS)

    Del Gratta, F.; Durif, M.; Fagault, Y.; Zdanevitch, I.

    2004-12-01

    This document presents the main techniques today available to characterize the formaldehyde concentrations in the air for different contexts: urban and rural areas or around industrial installations but also indoor and occupational area. It provides information to guide laboratories and research departments. A synthesis gives also the main emissions sources of these compounds as reference concentrations measured in different environments. (A.L.B.)

  1. Low geometry counter for the absolute measurement of the activity of alpha-emitting sources

    International Nuclear Information System (INIS)

    Garcia-Torano, E.; Acena, M.L.

    1989-01-01

    A low-geometry counter is described which allows the absolute determination of the activity for alpha-emitting sources. A Si implanted detector is used to obtain the spectrum of the sample. Two samples are measured with this counter and a 2 π gridded ion chamber. The results an their uncertainties for both instruments are discussed. (Author)

  2. Measuring light spectrum as a main indicator of artificial sources quality

    Directory of Open Access Journals (Sweden)

    Piotr Dąbrowski

    2015-05-01

    Full Text Available Objective: To compare different artificial light sources in different places where plant breeding is conduced. Methods: Measurements were conducted outdoor, in room, in greenhouse, under four panels with light emitting diodes, in phytotron, in dark room with various light sources and inside Sanyo versatile environmental chamber. The measurements were made by using SpectraPen SP100 (PSI, Czech Republic device. Results: Our result showed that spectrum measured outdoor during sunny day had only one peak at the wavelength of 485 nm (ca. 60000 relative units. On cloudy day, the trend of light spectrum curve was similar, but with lower values. At room conditions, the curve was more flat than outdoor. Under greenhouse conditions, the curve was similar to that measured outdoor. A few additional peaks on the curve appeared by adding high pressure sodium lamp. There were changes of curve under LED panels. Conclusions: It must be underlined that the most similar spectrum curve to daylight light has incandescent bulb and this light source should be preferred as support of daylight in greenhouses and as main source in phytotrons. Using high pressure sodium lamp in greenhouses as support of daylight cause increase in the red/far-red ratio and occurrence of a new peak on spectrum curve. The new possibilities are creating by LED panels with red and blue diodes.

  3. Estimating values for the moisture source load and buffering capacities from indoor climate measurements

    NARCIS (Netherlands)

    Schijndel, van A.W.M.

    2008-01-01

    The objective of this study is to investigate the potential for estimating values for the total size of human induced moisture source load and the total buffering (moisture storage) capacity of the interior objects with the use of relatively simple measurements and the use of heat, air, and moisture

  4. Using Generalizability Theory to Disattenuate Correlation Coefficients for Multiple Sources of Measurement Error.

    Science.gov (United States)

    Vispoel, Walter P; Morris, Carrie A; Kilinc, Murat

    2018-05-02

    Over the years, research in the social sciences has been dominated by reporting of reliability coefficients that fail to account for key sources of measurement error. Use of these coefficients, in turn, to correct for measurement error can hinder scientific progress by misrepresenting true relationships among the underlying constructs being investigated. In the research reported here, we addressed these issues using generalizability theory (G-theory) in both traditional and new ways to account for the three key sources of measurement error (random-response, specific-factor, and transient) that affect scores from objectively scored measures. Results from 20 widely used measures of personality, self-concept, and socially desirable responding showed that conventional indices consistently misrepresented reliability and relationships among psychological constructs by failing to account for key sources of measurement error and correlated transient errors within occasions. The results further revealed that G-theory served as an effective framework for remedying these problems. We discuss possible extensions in future research and provide code from the computer package R in an online supplement to enable readers to apply the procedures we demonstrate to their own research.

  5. HDR 192Ir source speed measurements using a high speed video camera

    International Nuclear Information System (INIS)

    Fonseca, Gabriel P.; Viana, Rodrigo S. S.; Yoriyaz, Hélio; Podesta, Mark; Rubo, Rodrigo A.; Sales, Camila P. de; Reniers, Brigitte; Verhaegen, Frank

    2015-01-01

    Purpose: The dose delivered with a HDR 192 Ir afterloader can be separated into a dwell component, and a transit component resulting from the source movement. The transit component is directly dependent on the source speed profile and it is the goal of this study to measure accurate source speed profiles. Methods: A high speed video camera was used to record the movement of a 192 Ir source (Nucletron, an Elekta company, Stockholm, Sweden) for interdwell distances of 0.25–5 cm with dwell times of 0.1, 1, and 2 s. Transit dose distributions were calculated using a Monte Carlo code simulating the source movement. Results: The source stops at each dwell position oscillating around the desired position for a duration up to (0.026 ± 0.005) s. The source speed profile shows variations between 0 and 81 cm/s with average speed of ∼33 cm/s for most of the interdwell distances. The source stops for up to (0.005 ± 0.001) s at nonprogrammed positions in between two programmed dwell positions. The dwell time correction applied by the manufacturer compensates the transit dose between the dwell positions leading to a maximum overdose of 41 mGy for the considered cases and assuming an air-kerma strength of 48 000 U. The transit dose component is not uniformly distributed leading to over and underdoses, which is within 1.4% for commonly prescribed doses (3–10 Gy). Conclusions: The source maintains its speed even for the short interdwell distances. Dose variations due to the transit dose component are much lower than the prescribed treatment doses for brachytherapy, although transit dose component should be evaluated individually for clinical cases

  6. Evaluation of antinociceptive activity of nanoliposome-encapsulated and free-form diclofenac in rats and mice

    Directory of Open Access Journals (Sweden)

    Goh JZ

    2014-12-01

    Full Text Available Jun Zheng Goh,1 Sook Nai Tang,1 Hoe Siong Chiong,1,2 Yoke Keong Yong,3 Ahmad Zuraini,1 Muhammad Nazrul Hakim1,4 1Department of Biomedical Sciences, Universiti Putra Malaysia, Serdang, Selangor, Malaysia; 2InQpharm Group, Kuala Lumpur, Malaysia; 3Department of Human Anatomy, 4Halal Product Research Institute, Universiti Putra Malaysia, Serdang, Selangor, Malaysia Abstract: Diclofenac is a nonsteroidal anti-inflammatory drug (NSAID that exhibits anti-inflammatory, antinociceptive, and antipyretic activities. Liposomes have been shown to improve the therapeutic efficacy of encapsulated drugs. The present study was conducted to compare the antinociceptive properties between liposome-encapsulated and free-form diclofenac in vivo via different nociceptive assay models. Liposome-encapsulated diclofenac was prepared using the commercialized proliposome method. Antinociceptive effects of liposome-encapsulated and free-form diclofenac were evaluated using formalin test, acetic acid-induced abdominal writhing test, Randall–Selitto paw pressure test, and plantar test. The results of the writhing test showed a significant reduction of abdominal constriction in all treatment groups in a dose-dependent manner. The 20 mg/kg liposome-encapsulated diclofenac demonstrated the highest antinociceptive effect at 78.97% compared with 55.89% in the free-form group at equivalent dosage. Both liposome-encapsulated and free-form diclofenac produced significant results in the late phase of formalin assay at a dose of 20 mg/kg, with antinociception percentages of 78.84% and 60.71%, respectively. Significant results of antinociception were also observed in both hyperalgesia assays. For Randall–Sellito assay, the highest antinociception effect of 71.38% was achieved with 20 mg/kg liposome-encapsulated diclofenac, while the lowest antinociceptive effect of 17.32% was recorded with 0 mg/kg liposome formulation, whereas in the plantar test, the highest antinociceptive effect

  7. Integration Strategy for Free-form Lithium Ion Battery: Material, Design to System level Applications

    KAUST Repository

    Kutbee, Arwa T.

    2017-10-31

    Power supply in any electronic system is a crucial necessity. Especially so in fully compliant personalized advanced healthcare electronic self-powered systems where we envision seamless integration of sensors and actuators with data management components in a single freeform platform to augment the quality of our healthcare, smart living and sustainable future. However, the status-quo energy storage (battery) options require packaging to protect the indwelling toxic materials against harsh physiological environment and vice versa, compromising its mechanical flexibility, conformability and wearability at the highest electrochemical performance. Therefore, clean and safe energy storage solutions for wearable and implantable electronics are needed to replace the commercially used unsafe lithium-ion batteries. This dissertation discusses a highly manufacturable integration strategy for a free-form lithium-ion battery towards a genuine mechanically compliant wearable system. We sequentially start with the optimization process for the preparation of all solid-state material comprising a ‘’Lithium-free’’ lithium-ion microbattery with a focus on thin film texture optimization of the cathode material. State of the art complementary metal oxide semiconductor technology was used for the thin film based battery. Additionally, this thesis reports successful development of a transfer-less scheme for a flexible battery with small footprint and free form factor in a high yield production process. The reliable process for the flexible lithium-ion battery achieves an enhanced energy density by three orders of magnitude compared to the available rigid ones. Interconnection and bonding procedures of the developed batteries are discussed for a reliable back end of line process flexible, stretchable and stackable modules. Special attention is paid to the advanced bonding, handling and packaging strategies of flexible batteries towards system-level applications. Finally, this

  8. Physics of the 252Cf-source-driven noise analysis measurement

    International Nuclear Information System (INIS)

    Valentine, T.E.; Mihalczo, J.T.; Perez, R.B.; Mattingly, J.K.

    1997-01-01

    The 252 Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method's broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between detectors, coherences, and ratios of spectral densities. All of these measured parameters can also be calculated using the MCNP-DSP Monte Carlo code. This paper presents a review of the time-domain signatures obtained from this measurement

  9. Galvanically Decoupled Current Source Modules for Multi-Channel Bioimpedance Measurement Systems

    Directory of Open Access Journals (Sweden)

    Roman Kusche

    2017-10-01

    Full Text Available Bioimpedance measurements have become a useful technique in the past several years in biomedical engineering. Especially, multi-channel measurements facilitate new imaging and patient monitoring techniques. While most instrumentation research has focused on signal acquisition and signal processing, this work proposes the design of an excitation current source module that can be easily implemented in existing or upcoming bioimpedance measurement systems. It is galvanically isolated to enable simultaneous multi-channel bioimpedance measurements with a very low channel-coupling. The system is based on a microcontroller in combination with a voltage-controlled current source circuit. It generates selectable sinusoidal excitation signals between 0.12 and 1.5 mA in a frequency range from 12 to 250 kHz, whereas the voltage compliance range is ±3.2 V. The coupling factor between two current sources, experimentally galvanically connected with each other, is measured to be less than −48 dB over the entire intended frequency range. Finally, suggestions for developments in the future are made.

  10. Assessment of grid optimisation measures for the German transmission grid using open source grid data

    Science.gov (United States)

    Böing, F.; Murmann, A.; Pellinger, C.; Bruckmeier, A.; Kern, T.; Mongin, T.

    2018-02-01

    The expansion of capacities in the German transmission grid is a necessity for further integration of renewable energy sources into the electricity sector. In this paper, the grid optimisation measures ‘Overhead Line Monitoring’, ‘Power-to-Heat’ and ‘Demand Response in the Industry’ are evaluated and compared against conventional grid expansion for the year 2030. Initially, the methodical approach of the simulation model is presented and detailed descriptions of the grid model and the used grid data, which partly originates from open-source platforms, are provided. Further, this paper explains how ‘Curtailment’ and ‘Redispatch’ can be reduced by implementing grid optimisation measures and how the depreciation of economic costs can be determined considering construction costs. The developed simulations show that the conventional grid expansion is more efficient and implies more grid relieving effects than the evaluated grid optimisation measures.

  11. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    Energy Technology Data Exchange (ETDEWEB)

    Burns, R.E. Jr.; O`Brien, J.M. Jr. [Atlan-Tech, Rosewll, GA (United States)

    1993-12-31

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison.

  12. Influence of neutron scattering and source extent on the measurement of neutron energy spectra at ASDEX

    International Nuclear Information System (INIS)

    Huebner, K.; Baetzner, R.; Roos, M.; Robouch, B.V.; Ingrosso, L.; Wurz, H.

    1987-08-01

    The problem of nuclear emulsion measurements at ASDEX is considered. Besides the application of the VINIA-3DAMC software, this needs a description of the plasma neutron source, a model of the ASDEX structure, and calculation of the response of the nuclear emulsion to the incoming spectral neutron fluence. The latter is essential for comparing the numerical results with measurements at ASDEX. To treat this part, the NEPMC software was developed. The aim of the present work is to demonstrate the feasibility, reliability and usefulness of the method. Therefore simplified treatments for the ASDEX model, the plasma neutron source and the track statistics in the NEPMC software were used. Such calculations are of interest not only for nuclear emulsion measurements as well as any other neutron diagnostics, but also for all problems of neutron shielding for other diagnostics. (orig./GG)

  13. Analysis of insertion device magnet measurements for the Advanced Light Source

    International Nuclear Information System (INIS)

    Marks, S.; Humphries, D.; Kincaid, B.M.; Schlueter, R.; Wang, C.

    1993-07-01

    The Advanced Light Source (ALS), which is currently being commissioned at Lawrence Berkeley Laboratory, is a third generation light source designed to produce XUV radiation of unprecedented brightness. To meet the high brightness goal the storage ring has been designed for very small electron beam emittance and the undulators installed in the ALS are built to a high degree of precision. The allowable magnetic field errors are driven by electron beam and radiation requirements. Detailed magnetic measurements and adjustments are performed on each undulator to qualify it for installation in the ALS. The first two ALS undulators, IDA and IDB, have been installed. This paper describes the program of measurements, data analysis, and adjustments carried out for these two devices. Calculations of the radiation spectrum, based upon magnetic measurements, are included. Final field integral distributions are also shown. Good field integral uniformity has been achieved using a novel correction scheme, which is also described

  14. Systematic investigation of background sources in neutron flux measurements with a proton-recoil silicon detector

    Energy Technology Data Exchange (ETDEWEB)

    Marini, P., E-mail: marini@cenbg.in2p3.fr [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France); Mathieu, L. [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France); Acosta, L. [Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, México D.F. 01000 (Mexico); Aïche, M.; Czajkowski, S.; Jurado, B.; Tsekhanovich, I. [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France)

    2017-01-01

    Proton-recoil detectors (PRDs), based on the well known standard H(n,p) elastic scattering cross section, are the preferred instruments to perform precise quasi-absolute neutron flux measurements above 1 MeV. The limitations of using a single silicon detector as PRD at a continuous neutron beam facility are investigated, with the aim of extending such measurements to neutron energies below 1 MeV. This requires a systematic investigation of the background sources affecting the neutron flux measurement. Experiments have been carried out at the AIFIRA facility to identify these sources. A study on the role of the silicon detector thickness on the background is presented and an energy limit on the use of a single silicon detector to achieve a neutron flux precision better than 1% is given.

  15. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    International Nuclear Information System (INIS)

    Burns, R.E. Jr.; O'Brien, J.M. Jr.

    1993-01-01

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison

  16. Measures Against-Illicit Trafficking of Nuclear Materials and Other Radioactive Sources

    International Nuclear Information System (INIS)

    Barakat, M.B.; Nassef, M.H.; El Mongy, S.A.

    2008-01-01

    Since the early nineties, illicit trafficking (IT) of nuclear materials and radioactive sources appeared as a new trend which raised the concern of the international community due to the grave consequences that would merge if these materials or radioactive sources fell into the hands of terrorist groups. However, by the end of the last century illicit trafficking of nuclear materials and radioactive sources lost its considerable salience, in spite of seizure of considerable amounts of 2 '3'5U (76% enrichment) in Bulgaria (May 1999) and also 235 U (30% enrichment) in Georgia (April 2000). Nevertheless, IT should be always considered as a continued and viable threat to the international community. Awareness of the problem should be developed and maintained among concerned circles as the first step towards combating illicit trafficking of nuclear materials and radioactive sources. Illicit trafficking of nuclear and radioactive materials needs serious consideration and proper attention by the governmental law enforcement authorities. Measures to combat with IT of nuclear material or radioactive sources should be effective in recovery, of stolen, removed or lost nuclear materials or radioactive sources due to the failure of the physical protection system or the State System Accounting and Control (SSAC) system which are normally applied for protecting these materials against illegal actions. Measures such as use of modern and efficient radiation monitoring equipment at the borders inspection points, is an important step in preventing the illicit trafficking of nuclear and radioactive materials across the borders. Also providing radiological training to specific personnel and workers in this field will minimize the consequences of a radiological attack in case of its occurrence. There is a real need to start to enter into cooperative agreements to strengthen borders security under the umbrella of IAEA to faster as an international cooperation in the illicit trafficking

  17. Apparatus for measuring moisture in moving bulk material using a lithium-7 radiation source

    International Nuclear Information System (INIS)

    Ashe, J.B.

    1976-01-01

    A nucleonic device is described for measuring the moisture content of bulk materials using a radioisotopic fast-neutron source such as lithium-7 admixed with an alpha-particle emitter such as americium-241 as a means of minimizing the thickness of the layer of bulk material required proximate to the moisture sensor for a neutron-reflection moisture gauge for proper operation of said gauge. Minimization of the required thickness of the bulk material permits use of a neutron-reflection moisture gauge for measurements of bulk materials on lightly-loaded belts and other types of conveyors where measurements have previously been impracticable

  18. Lithium Blanket Module dosimetry measurements at the LOTUS 14-MeV neutron source facility

    International Nuclear Information System (INIS)

    Tsang, F.Y.; Leo, W.R.; Sahraoui, C.; Wuthrich, S.; Harker, Y.D.

    1986-01-01

    This paper describes the measurements and results of the dosimeter material reaction rates inside the Lithium Blanket Module (LBM) after irradiation by the LOTUS 14-MeV neutron source at the Ecole Polytechnique Federale de Lausanne. The measurement program has been designed to utilize sets of passive dosimeter materials in the form of foils and wires. The dosimetry materials reaction thresholds and interaction response ranges chosen for this series of measurements encompass the entire neutron spectra along the full length of the LBM fuel rods

  19. Measurements of Linac4 H$^{-}$ ion source beam with a magnetized Einzel lens electron dump

    CERN Document Server

    Midttun, O; Scrivens, R

    2014-01-01

    Linac4 is a part of the upgrade of CERN’s accelerator complex for increased luminosity in the LHC. A new system to extract the ion beam from the plasma generator has been designed and tested, in order to improve the reliability and beam optics of the pulsed H- ion source. This paper presents the successfully implemented extraction system and three different beam measurements. The simulations compare well to the measurements and show that the plasma density was too low for the extraction system design during the measurements.

  20. Measuring impairment when diagnosing adolescent ADHD: Differentiating problems due to ADHD versus other sources.

    Science.gov (United States)

    Vazquez, Alejandro L; H Sibley, Margaret; Campez, Mileini

    2018-04-13

    The DSM-5 requires clinicians to link ADHD symptoms to clinically meaningful impairments in daily life functioning. Measuring impairment during ADHD assessments may be particularly challenging in adolescence, when ADHD is often not the sole source of a youth's difficulties. Existing impairment rating scales are criticized for not specifying ADHD as the source of impairment in their instructions, leading to potential problems with rating scale specificity. The current study utilized a within subjects design (N = 107) to compare parent report of impairment on two versions of a global impairment measure: one that specified ADHD as the source of impairment (Impairment Rating Scale-ADHD) and a standard version that did not (Impairment Rating Scale). On the standard family impairment item, parents endorsed greater impairment as compared to the IRS-ADHD. This finding was particularly pronounced when parents reported high levels of parenting stress. More severe ADHD symptoms were associated with greater concordance between the two versions. Findings indicate that adolescent family related impairments reported during ADHD assessments may be due to sources other than ADHD symptoms, such as developmental maladjustment. To prevent false positive diagnoses, symptom-specific wording may optimize impairment measures when assessing family functioning in diagnostic assessments for adolescents with ADHD. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Comparison of sources of submicron particle number concentrations measured at two sites in Rochester, NY.

    Science.gov (United States)

    Kasumba, John; Hopke, Philip K; Chalupa, David C; Utell, Mark J

    2009-09-01

    Sources contributing to the submicron particles (100-470 nm) measured between January 2002 and December 2007 at two different New York State Department of Environmental Conservation (NYS DEC) sites in Rochester, NY were identified and apportioned using a bilinear receptor model, positive matrix factorization (PMF). Measurements of aerosol size distributions and number concentrations for particles in the size range of 10-500 nm have been made since December 2001 to date in Rochester. The measurements are being made using a scanning mobility particle sizer (SMPS) consisting of a DMA and a CPC (TSI models 3071 and 3010, respectively). From December 2001 to March 2004, particle measurements were made at the NYS DEC site in downtown Rochester, but it was moved to the eastside of Rochester in May 2004. Each measurement period was divided into three seasons i.e., winter (December, January, and February), summer (June, July, and August), and the transitional periods (March, April, May, September, October, and November) so as to avoid experimental uncertainty resulting from too large season-to-season variability in ambient temperature and solar photon intensity that would lead to unstable/non-stationary size distributions. Therefore, the seasons were analyzed independently for possible sources. Ten sources were identified at both sites and these include traffic, nucleation, residential/commercial heating, industrial emissions, secondary nitrate, ozone- rich secondary aerosol, secondary sulfate, regionally transported aerosol, and a mixed source of nucleation and traffic. These results show that the measured total outdoor particle number concentrations in Rochester generally vary with similar temporal patterns, suggesting that the central monitoring site data can be used to estimate outdoor exposure in other parts of the city.

  2. Interpretation of UV radiometric measurements of spectrally non-uniform sources

    International Nuclear Information System (INIS)

    Murphy, P.J.; Gardner, D.G.

    1988-01-01

    Narrow bandpass UV radiometers are used in a variety of high-temperature measurement applications. Significant systematic errors, in the form of an apparent wavelength shift in the system response curve, may be introduced when interpreting data obtained from spectrally nonuniform sources. Theoretical calculations, using transmission curves from commercially available narrow bandpass filters, show that the apparent shift in the system spectral response is a function of temperature for a blackbody source. A brief comparison between the theoretical analysis and experimentaal data is presented

  3. Monte Carlo calculations and measurements of spectra from a C-14 source

    International Nuclear Information System (INIS)

    Borg, J.

    1996-05-01

    To perform Monte Carlo simulations it is necessary to model the physical geometries i.e., the source and detector geometry. However, a complete model of the physical geometry may not be possible or may result in a very low calculation efficiency. Substituting the complete source model with a simplified model is one way of increasing the calculation efficiency. In this report, the study of a simplified model of a 14 C source is described. Results of Monte Carlo calculations with the EGS4 code are compared with measurements with a β spectrometer consisting of two coaxial Si detectors, and a low-energy photon spectrometer being a Si(Li) detector. Calculations and measurements show generally good agreement. However, the difference (a factor of 4) between calculated and measured response to electrons for the Si(Li) detector indicates that this detector has a dead layer about 12 μm thick instead of 0.2 μm as reported by the manufacturer. The efficiency of the calculations is increased by a factor of 10, when the complete source model is replaced by the simplified source model. This reduces the calculation time of detector responses to a few days instead of weeks on the NRC SGI R4400 computers. Good agreement between measured and calculated data also verifies that the MC code EGS4 is a reliable and useful tool for simulating coupled electron and photon transport for particles with energies down to a few keV. (au) 3 tabs., 15 ills., 11 refs

  4. Thickness measurement for the different metals by using Cs-137 gamma source with gamma transmission technique

    International Nuclear Information System (INIS)

    Bueyuek, B.; Tugrul, B.

    2009-01-01

    The purpose of this study is an experimental analysis of thickness measurement for various metals with the gamma transmission technique using Cs-137 as the radioisotope source. Lead, steel, brass, and aluminum, which are frequently used metals in industry, were chosen for the experiments. As the radioisotope source Cs-137 was preferred for the study since it has long half-life, it is mono energetic, and it penetrates the metals that were studied. Experiments were observed in the constant experimental geometry. Calibration curves for the four metal samples were plotted using the obtained results. To test the plotted calibration curves, counts for determining thickness measurement were collected for each sample and the obtained relative count values were used in conjunction with the plotted calibration curves for each sample to determine its thickness. The thicknesses of the samples have been measured with a micrometer and the results were comparatively analyzed with the measurement results obtained by the gamma transmission technique. The results of the analyses revealed that the thickness measurement values obtained with the gamma transmission technique and the thickness measurement values obtained with the conventional technique significantly converge to each other and the difference between the two values is at an acceptable level. Therefore the reliability of thickness measurements with the gamma transmission technique and the resulting calibration curves have been demonstrated.

  5. Lower-energy neutron sources for increasing the sensitivity of nuclear gages for measuring the water content of bulk materials

    International Nuclear Information System (INIS)

    Bailey, S.M.

    1977-01-01

    The sensitivity of a gage using a nuclear source for measuring the water content of bulk materials, such as plastic concrete, is increased by use of a lithium or fluorine neutron nuclear source. 3 figures

  6. The continental source of glyoxal estimated by the synergistic use of spaceborne measurements and inverse modelling

    Directory of Open Access Journals (Sweden)

    A. Richter

    2009-11-01

    Full Text Available Tropospheric glyoxal and formaldehyde columns retrieved from the SCIAMACHY satellite instrument in 2005 are used with the IMAGESv2 global chemistry-transport model and its adjoint in a two-compound inversion scheme designed to estimate the continental source of glyoxal. The formaldehyde observations provide an important constraint on the production of glyoxal from isoprene in the model, since the degradation of isoprene constitutes an important source of both glyoxal and formaldehyde. Current modelling studies underestimate largely the observed glyoxal satellite columns, pointing to the existence of an additional land glyoxal source of biogenic origin. We include an extra glyoxal source in the model and we explore its possible distribution and magnitude through two inversion experiments. In the first case, the additional source is represented as a direct glyoxal emission, and in the second, as a secondary formation through the oxidation of an unspecified glyoxal precursor. Besides this extra source, the inversion scheme optimizes the primary glyoxal and formaldehyde emissions, as well as their secondary production from other identified non-methane volatile organic precursors of anthropogenic, pyrogenic and biogenic origin.

    In the first inversion experiment, the additional direct source, estimated at 36 Tg/yr, represents 38% of the global continental source, whereas the contribution of isoprene is equally important (30%, the remainder being accounted for by anthropogenic (20% and pyrogenic fluxes. The inversion succeeds in reducing the underestimation of the glyoxal columns by the model, but it leads to a severe overestimation of glyoxal surface concentrations in comparison with in situ measurements. In the second scenario, the inferred total global continental glyoxal source is estimated at 108 Tg/yr, almost two times higher than the global a priori source. The extra secondary source is the largest contribution to the global glyoxal

  7. A small-plane heat source method for measuring the thermal conductivities of anisotropic materials

    Science.gov (United States)

    Cheng, Liang; Yue, Kai; Wang, Jun; Zhang, Xinxin

    2017-07-01

    A new small-plane heat source method was proposed in this study to simultaneously measure the in-plane and cross-plane thermal conductivities of anisotropic insulating materials. In this method the size of the heat source element is smaller than the sample size and the boundary condition is thermal insulation due to no heat flux at the edge of the sample during the experiment. A three-dimensional model in a rectangular coordinate system was established to exactly describe the heat transfer process of the measurement system. Using the Laplace transform, variable separation, and Laplace inverse transform methods, the analytical solution of the temperature rise of the sample was derived. The temperature rises calculated by the analytical solution agree well with the results of numerical calculation. The result of the sensitivity analysis shows that the sensitivity coefficients of the estimated thermal conductivities are high and uncorrelated to each other. At room temperature and in a high-temperature environment, experimental measurements of anisotropic silica aerogel were carried out using the traditional one-dimensional plane heat source method and the proposed method, respectively. The results demonstrate that the measurement method developed in this study is effective and feasible for simultaneously obtaining the in-plane and cross-plane thermal conductivities of the anisotropic materials.

  8. Measurements of beam current density and proton fraction of a permanent-magnet microwave ion source

    Energy Technology Data Exchange (ETDEWEB)

    Waldmann, Ole; Ludewigt, Bernhard [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, California 94720 (United States)

    2011-11-15

    A permanent-magnet microwave ion source has been built for use in a high-yield, compact neutron generator. The source has been designed to produce up to 100 mA of deuterium and tritium ions. The electron-cyclotron resonance condition is met at a microwave frequency of 2.45 GHz and a magnetic field strength of 87.5 mT. The source operates at a low hydrogen gas pressure of about 0.15 Pa. Hydrogen beams with a current density of 40 mA/cm{sup 2} have been extracted at a microwave power of 450 W. The dependence of the extracted proton beam fraction on wall materials and operating parameters was measured and found to vary from 45% for steel to 95% for boron nitride as a wall liner material.

  9. Measurements of beam current density and proton fraction of a permanent-magnet microwave ion source.

    Science.gov (United States)

    Waldmann, Ole; Ludewigt, Bernhard

    2011-11-01

    A permanent-magnet microwave ion source has been built for use in a high-yield, compact neutron generator. The source has been designed to produce up to 100 mA of deuterium and tritium ions. The electron-cyclotron resonance condition is met at a microwave frequency of 2.45 GHz and a magnetic field strength of 87.5 mT. The source operates at a low hydrogen gas pressure of about 0.15 Pa. Hydrogen beams with a current density of 40 mA/cm(2) have been extracted at a microwave power of 450 W. The dependence of the extracted proton beam fraction on wall materials and operating parameters was measured and found to vary from 45% for steel to 95% for boron nitride as a wall liner material. © 2011 American Institute of Physics

  10. RECENT BEAM MEASUREMENTS AND NEW INSTRUMENTATION AT THE ADVANCED LIGHT SOURCE

    International Nuclear Information System (INIS)

    Sannibale, Fernando; Baptiste, Kenneth; Barry, Walter; Chin, Michael; Filippetto, Daniele; Jaegerhofer, Lukas; Julian, James; Kwiatkowski, Slawomir; Low, Raymond; Plate, David; Portmann, Gregory; Robin, David; Scarvie, Tomas; Stupakov, Gennady; Weber, Jonah; Zolotorev, Max

    2008-01-01

    The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and used in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years

  11. Measurement of performance parameters of plasma source for plasma opening switch on Qiangguang-Ⅰ generator

    International Nuclear Information System (INIS)

    Luo Weixi; Zeng Zhengzhong; Lei Tianshi; Wang Liangping; Hu Yixiang; Sun Tieping; Huang Tao

    2012-01-01

    The plasma source (cable guns) of the plasma opening switch (POS) on Qiangguang Ⅰ generator was chosen as the study object. The plasma source performance was investigated by using charge collectors. Experimental results show that the plasma ejection density is positively correlated with the structural parameter, the distance between gun core tip and muzzle plane, and the plasma ejection velocity is negatively correlated with the parameter. The increasing rate of plasma ejection density is less than that of drive current. As far as a plasma source with tens of cable plasma guns is concerned, the influence of single cable gun's discharge dispersancy on plasma uniformity is little. Analysis of uncertainty shows that the uncertainty of measurement can be reduced by increasing the number of experiments and averaging the results. The combined standard uncertainty of plasma ejection density is less than 10%. (authors)

  12. Simulation of neutron multiplicity measurements using Geant4. Open source software for nuclear arms control

    Energy Technology Data Exchange (ETDEWEB)

    Kuett, Moritz

    2016-07-07

    Nuclear arms control, including nuclear safeguards and verification technologies for nuclear disarmament typically use software as part of many different technological applications. This thesis proposes to use three open source criteria for such software, allowing users and developers to have free access to a program, have access to the full source code and be able to publish modifications for the program. This proposition is presented and analyzed in detail, together with the description of the development of ''Open Neutron Multiplicity Simulation'', an open source software tool to simulate neutron multiplicity measurements. The description includes physical background of the method, details of the developed program and a comprehensive set of validation calculations.

  13. A novel method for direct localized sound speed measurement using the virtual source paradigm

    DEFF Research Database (Denmark)

    Byram, Brett; Trahey, Gregg E.; Jensen, Jørgen Arendt

    2007-01-01

    ) mediums. The inhomogeneous mediums were arranged as an oil layer, one 6 mm thick and the other 11 mm thick, on top of a water layer. To complement the phantom studies, sources of error for spatial registration of virtual detectors were simulated. The sources of error presented here are multiple sound...... registered virtual detector. Between a pair of registered virtual detectors a spherical wave is propagated. By beamforming the received data the time of flight between the two virtual sources can be calculated. From this information the local sound speed can be estimated. Validation of the estimator used...... both phantom and simulation results. The phantom consisted of two wire targets located near the transducer's axis at depths of 17 and 28 mm. Using this phantom the sound speed between the wires was measured for a homogeneous (water) medium and for two inhomogeneous (DB-grade castor oil and water...

  14. Characterization of the main error sources of chromatic confocal probes for dimensional measurement

    International Nuclear Information System (INIS)

    Nouira, H; El-Hayek, N; Yuan, X; Anwer, N

    2014-01-01

    Chromatic confocal probes are increasingly used in high-precision dimensional metrology applications such as roughness, form, thickness and surface profile measurements; however, their measurement behaviour is not well understood and must be characterized at a nanometre level. This paper provides a calibration bench for the characterization of two chromatic confocal probes of 20 and 350 µm travel ranges. The metrology loop that includes the chromatic confocal probe is stable and enables measurement repeatability at the nanometer level. With the proposed system, the major error sources, such as the relative axial and radial motions of the probe with respect to the sample, the material, colour and roughness of the measured sample, the relative deviation/tilt of the probe and the scanning speed are identified. Experimental test results show that the chromatic confocal probes are sensitive to these errors and that their measurement behaviour is highly dependent on them. (paper)

  15. 228Ra and 226Ra measurement on a BaSO4 co-precipitation source

    International Nuclear Information System (INIS)

    Medley, Peter; Martin, Paul; Bollhöfer, Andreas; Parry, David

    2015-01-01

    One of the most commonly-used methods for determination of 226 Ra, particularly in water samples, utilises co-precipitation of Ra with BaSO 4 , followed by microfiltration to produce a source for alpha counting. This paper describes two extensions to BaSO 4 co-precipitation methods which enable determination of 228 Ra using the same source. The adaptations presented here do not introduce any contaminants that will affect the separation of radium or alpha counting for 226 Ra, and can be used for re-analysis of already existing sources prepared by BaSO 4 co-precipitation. The first adaptation uses detection of 228 Ac on the source by gamma spectrometry. The detection efficiency is high, allowing analysis of water samples at sufficiently low activity to be suitable in testing for compliance with drinking water quality standards. As 228 Ac grows in quickly, taking less than 2 days to reach equilibrium with the 228 Ra parent, this can also be useful in radiological emergency response situations. The second adaptation incorporates a method for the digestion of BaSO 4 sources, allowing separation of thorium and subsequent determination of 228 Th activity. Although ingrowth periods for 228 Th can be lengthy, very low detection limits for 228 Ra can be achieved with this technique. - Highlights: • We developed two methods for 228 Ra measurement on Ba(Ra)SO 4 co-precipitation sources. • Measurement by gamma spectrometry using the daughter 228 Ac is rapid. • Detection limits are suitable for assessment of drinking water quality. • The second approach uses alpha spectrometry on a separated Th fraction. • This is more sensitive than gamma spectrometry after an ingrowth period greater than about 1 month

  16. Investigation of uniformity field generated from freeform lens with UV LED exposure system

    Science.gov (United States)

    Ciou, F. Y.; Chen, Y. C.; Pan, C. T.; Lin, P. H.; Lin, P. H.; Hsu, F. T.

    2015-03-01

    In the exposure process, the intensity and uniformity of light in the exposure area directly influenced the precision of products. UV-LED (Ultraviolet Light-Emitting Diode) exposure system was established to reduce the radiation leakage and increase the energy efficiency for energy saving. It is a trend that conventional mercury lamp could be replaced with UV-LED exposure system. This study was based on the law of conservation of energy and law of refraction of optical field distributing on the target plane. With these, a freeform lens with uniform light field of main exposure area could be designed. The light outside the exposure area could be concentrated into the area to improve the intensity of light. The refraction index and UV transmittance of Polydimethylsiloxane (PDMS) is 1.43 at 385 nm wavelength and 85-90%, respectively. The PDMS was used to fabricate the optics lens for UV-LEDs. The average illumination and the uniformity could be obtained by increasing the number of UV-LEDs and the spacing of different arrangement modes. After exposure process with PDMS lens, about 5% inaccuracy was obtained. Comparing to 10% inaccuracy of general exposure system, it shows that it is available to replace conventional exposure lamp with using UV-LEDs.

  17. New paradigms in internal architecture design and freeform fabrication of tissue engineering porous scaffolds.

    Science.gov (United States)

    Yoo, Dongjin

    2012-07-01

    Advanced additive manufacture (AM) techniques are now being developed to fabricate scaffolds with controlled internal pore architectures in the field of tissue engineering. In general, these techniques use a hybrid method which combines computer-aided design (CAD) with computer-aided manufacturing (CAM) tools to design and fabricate complicated three-dimensional (3D) scaffold models. The mathematical descriptions of micro-architectures along with the macro-structures of the 3D scaffold models are limited by current CAD technologies as well as by the difficulty of transferring the designed digital models to standard formats for fabrication. To overcome these difficulties, we have developed an efficient internal pore architecture design system based on triply periodic minimal surface (TPMS) unit cell libraries and associated computational methods to assemble TPMS unit cells into an entire scaffold model. In addition, we have developed a process planning technique based on TPMS internal architecture pattern of unit cells to generate tool paths for freeform fabrication of tissue engineering porous scaffolds. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. Freeform drop-on-demand laser printing of 3D alginate and cellular constructs

    International Nuclear Information System (INIS)

    Xiong, Ruitong; Zhang, Zhengyi; Chai, Wenxuan; Huang, Yong; Chrisey, Douglas B

    2015-01-01

    Laser printing is an orifice-free printing approach and has been investigated for the printing of two-dimensional patterns and simple three-dimensional (3D) constructs. To demonstrate the potential of laser printing as an effective bioprinting technique, both straight and Y-shaped tubes have been freeform printed using two different bioinks: 8% alginate solution and 2% alginate-based mouse fibroblast suspension. It has been demonstrated that 3D cellular tubes, including constructs with bifurcated overhang structures, can be adequately fabricated under optimal printing conditions. The post-printing cell viabilities immediately after printing as well as after 24 h incubation are above 60% for printed straight and Y-shaped fibroblast tubes. During fabrication, overhang and spanning structures can be printed using a dual-purpose crosslinking solution, which also functions as a support material. The advancement distance of gelation reaction front after a cycle time of the receiving platform downward motion should be estimated for experimental planning. The optimal downward movement step size of receiving platform should be chosen to be equal to the height of ungelled portion of a previously printed layer. (paper)

  19. Characterization of New PEEK/HA Composites with 3D HA Network Fabricated by Extrusion Freeforming

    Directory of Open Access Journals (Sweden)

    Mohammad Vaezi

    2016-05-01

    Full Text Available Addition of bioactive materials such as calcium phosphates or Bioglass, and incorporation of porosity into polyetheretherketone (PEEK has been identified as an effective approach to improve bone-implant interfaces and osseointegration of PEEK-based devices. In this paper, a novel production technique based on the extrusion freeforming method is proposed that yields a bioactive PEEK/hydroxyapatite (PEEK/HA composite with a unique configuration in which the bioactive phase (i.e., HA distribution is computer-controlled within a PEEK matrix. The 100% interconnectivity of the HA network in the biocomposite confers an advantage over alternative forms of other microstructural configurations. Moreover, the technique can be employed to produce porous PEEK structures with controlled pore size and distribution, facilitating greater cellular infiltration and biological integration of PEEK composites within patient tissue. The results of unconfined, uniaxial compressive tests on these new PEEK/HA biocomposites with 40% HA under both static and cyclic mode were promising, showing the composites possess yield and compressive strength within the range of human cortical bone suitable for load bearing applications. In addition, preliminary evidence supporting initial biological safety of the new technique developed is demonstrated in this paper. Sufficient cell attachment, sustained viability in contact with the sample over a seven-day period, evidence of cell bridging and matrix deposition all confirmed excellent biocompatibility.

  20. Generating Free-Form Grid Truss Structures from 3D Scanned Point Clouds

    Directory of Open Access Journals (Sweden)

    Hui Ding

    2017-01-01

    Full Text Available Reconstruction, according to physical shape, is a novel way to generate free-form grid truss structures. 3D scanning is an effective means of acquiring physical form information and it generates dense point clouds on surfaces of objects. However, generating grid truss structures from point clouds is still a challenge. Based on the advancing front technique (AFT which is widely used in Finite Element Method (FEM, a scheme for generating grid truss structures from 3D scanned point clouds is proposed in this paper. Based on the characteristics of point cloud data, the search box is adopted to reduce the search space in grid generating. A front advancing procedure suit for point clouds is established. Delaunay method and Laplacian method are used to improve the quality of the generated grids, and an adjustment strategy that locates grid nodes at appointed places is proposed. Several examples of generating grid truss structures from 3D scanned point clouds of seashells are carried out to verify the proposed scheme. Physical models of the grid truss structures generated in the examples are manufactured by 3D print, which solidifies the feasibility of the scheme.

  1. Characterization of New PEEK/HA Composites with 3D HA Network Fabricated by Extrusion Freeforming.

    Science.gov (United States)

    Vaezi, Mohammad; Black, Cameron; Gibbs, David M R; Oreffo, Richard O C; Brady, Mark; Moshrefi-Torbati, Mohamed; Yang, Shoufeng

    2016-05-26

    Addition of bioactive materials such as calcium phosphates or Bioglass, and incorporation of porosity into polyetheretherketone (PEEK) has been identified as an effective approach to improve bone-implant interfaces and osseointegration of PEEK-based devices. In this paper, a novel production technique based on the extrusion freeforming method is proposed that yields a bioactive PEEK/hydroxyapatite (PEEK/HA) composite with a unique configuration in which the bioactive phase (i.e., HA) distribution is computer-controlled within a PEEK matrix. The 100% interconnectivity of the HA network in the biocomposite confers an advantage over alternative forms of other microstructural configurations. Moreover, the technique can be employed to produce porous PEEK structures with controlled pore size and distribution, facilitating greater cellular infiltration and biological integration of PEEK composites within patient tissue. The results of unconfined, uniaxial compressive tests on these new PEEK/HA biocomposites with 40% HA under both static and cyclic mode were promising, showing the composites possess yield and compressive strength within the range of human cortical bone suitable for load bearing applications. In addition, preliminary evidence supporting initial biological safety of the new technique developed is demonstrated in this paper. Sufficient cell attachment, sustained viability in contact with the sample over a seven-day period, evidence of cell bridging and matrix deposition all confirmed excellent biocompatibility.

  2. A Robot Trajectory Optimization Approach for Thermal Barrier Coatings Used for Free-Form Components

    Science.gov (United States)

    Cai, Zhenhua; Qi, Beichun; Tao, Chongyuan; Luo, Jie; Chen, Yuepeng; Xie, Changjun

    2017-10-01

    This paper is concerned with a robot trajectory optimization approach for thermal barrier coatings. As the requirements of high reproducibility of complex workpieces increase, an optimal thermal spraying trajectory should not only guarantee an accurate control of spray parameters defined by users (e.g., scanning speed, spray distance, scanning step, etc.) to achieve coating thickness homogeneity but also help to homogenize the heat transfer distribution on the coating surface. A mesh-based trajectory generation approach is introduced in this work to generate path curves on a free-form component. Then, two types of meander trajectories are generated by performing a different connection method. Additionally, this paper presents a research approach for introducing the heat transfer analysis into the trajectory planning process. Combining heat transfer analysis with trajectory planning overcomes the defects of traditional trajectory planning methods (e.g., local over-heating), which helps form the uniform temperature field by optimizing the time sequence of path curves. The influence of two different robot trajectories on the process of heat transfer is estimated by coupled FEM models which demonstrates the effectiveness of the presented optimization approach.

  3. In situ 3D nanoprinting of free-form coupling elements for hybrid photonic integration

    Science.gov (United States)

    Dietrich, P.-I.; Blaicher, M.; Reuter, I.; Billah, M.; Hoose, T.; Hofmann, A.; Caer, C.; Dangel, R.; Offrein, B.; Troppenz, U.; Moehrle, M.; Freude, W.; Koos, C.

    2018-04-01

    Hybrid photonic integration combines complementary advantages of different material platforms, offering superior performance and flexibility compared with monolithic approaches. This applies in particular to multi-chip concepts, where components can be individually optimized and tested. The assembly of such systems, however, requires expensive high-precision alignment and adaptation of optical mode profiles. We show that these challenges can be overcome by in situ printing of facet-attached beam-shaping elements. Our approach allows precise adaptation of vastly dissimilar mode profiles and permits alignment tolerances compatible with cost-efficient passive assembly techniques. We demonstrate a selection of beam-shaping elements at chip and fibre facets, achieving coupling efficiencies of up to 88% between edge-emitting lasers and single-mode fibres. We also realize printed free-form mirrors that simultaneously adapt beam shape and propagation direction, and we explore multi-lens systems for beam expansion. The concept paves the way to automated assembly of photonic multi-chip systems with unprecedented performance and versatility.

  4. Metallurgical Mechanisms Controlling Mechanical Properties of Aluminum Alloy 2219 Produced By Electron Beam Freeform Fabrication

    Science.gov (United States)

    Domack, Marcia S.; Taminger, Karen M. B.; Begley, Matthew

    2006-01-01

    The electron beam freeform fabrication (EBF3) layer-additive manufacturing process has been developed to directly fabricate complex geometry components. EBF3 introduces metal wire into a molten pool created on the surface of a substrate by a focused electron beam. Part geometry is achieved by translating the substrate with respect to the beam to build the part one layer at a time. Tensile properties have been demonstrated for electron beam deposited aluminum and titanium alloys that are comparable to wrought products, although the microstructures of the deposits exhibit features more typical of cast material. Understanding the metallurgical mechanisms controlling mechanical properties is essential to maximizing application of the EBF3 process. In the current study, mechanical properties and resulting microstructures were examined for aluminum alloy 2219 fabricated over a range of EBF3 process variables. Material performance was evaluated based on tensile properties and results were compared with properties of Al 2219 wrought products. Unique microstructures were observed within the deposited layers and at interlayer boundaries, which varied within the deposit height due to microstructural evolution associated with the complex thermal history experienced during subsequent layer deposition. Microstructures exhibited irregularly shaped grains, typically with interior dendritic structures, which were described based on overall grain size, morphology, distribution, and dendrite spacing, and were correlated with deposition parameters. Fracture features were compared with microstructural elements to define fracture paths and aid in definition of basic processing-microstructure-property correlations.

  5. Development of a hybrid scaffold with synthetic biomaterials and hydrogel using solid freeform fabrication technology

    International Nuclear Information System (INIS)

    Shim, Jin-Hyung; Park, Min; Park, Jaesung; Cho, Dong-Woo; Kim, Jong Young

    2011-01-01

    Natural biomaterials such as hyaluronic acid, gelatin and collagen provide excellent environments for tissue regeneration. Furthermore, gel-state natural biomaterials are advantageous for encapsulating cells and growth factors. In cell printing technology, hydrogel which contains cells was printed directly to form three-dimensional (3D) structures for tissue or organ regeneration using various types of printers. However, maintaining the 3D shape of the printed structure, which is made only of the hydrogel, is very difficult due to its weak mechanical properties. In this study, we developed a hybrid scaffold consisting of synthetic biomaterials and natural hydrogel using a multi-head deposition system, which is useful in solid freeform fabrication technology. The hydrogel was intentionally infused into the space between the lines of a synthetic biomaterial-based scaffold. The cellular efficacy of the hybrid scaffold was validated using rat primary hepatocytes and a mouse pre-osteoblast MC3T3-E1 cell line. In addition, the collagen hydrogel, which encapsulates cells, was dispensed and the viability of the cells observed. We demonstrated superior effects of the hybrid scaffold on cell adhesion and proliferation and showed the high viability of dispensed cells.

  6. Solid freeform-fabricated scaffolds designed to carry multicellular mesenchymal stem cell spheroids for cartilage regeneration

    Directory of Open Access Journals (Sweden)

    G-S Huang

    2013-10-01

    Full Text Available Three-dimensional (3D cellular spheroids have recently emerged as a new trend to replace suspended single cells in modern cell-based therapies because of their greater regeneration capacities in vitro. They may lose the 3D structure during a change of microenvironment, which poses challenges to their translation in vivo. Besides, the conventional microporous scaffolds may have difficulty in accommodating these relatively large spheroids. Here we revealed a novel design of microenvironment for delivering and sustaining the 3D spheroids. Biodegradable scaffolds with macroporosity to accommodate mesenchymal stem cell (MSC spheroids were made by solid freeform fabrication (SFF from the solution of poly(D,L-lactide-co-glycolide. Their internal surface was modified with chitosan following air plasma treatment in order to preserve the morphology of the spheroids. It was demonstrated that human MSC spheroids loaded in SFF scaffolds produced a significantly larger amount of cartilage-associated extracellular matrix in vitro and in NOD/SCID mice compared to single cells in the same scaffolds. Implantation of MSC spheroid-loaded scaffolds into the chondral defects of rabbit knees showed superior cartilage regeneration. This study establishes new perspectives in designing the spheroid-sustaining microenvironment within a tissue engineering scaffold for in vivo applications.

  7. High order statistical signatures from source-driven measurements of subcritical fissile systems

    International Nuclear Information System (INIS)

    Mattingly, J.K.

    1998-01-01

    This research focuses on the development and application of high order statistical analyses applied to measurements performed with subcritical fissile systems driven by an introduced neutron source. The signatures presented are derived from counting statistics of the introduced source and radiation detectors that observe the response of the fissile system. It is demonstrated that successively higher order counting statistics possess progressively higher sensitivity to reactivity. Consequently, these signatures are more sensitive to changes in the composition, fissile mass, and configuration of the fissile assembly. Furthermore, it is shown that these techniques are capable of distinguishing the response of the fissile system to the introduced source from its response to any internal or inherent sources. This ability combined with the enhanced sensitivity of higher order signatures indicates that these techniques will be of significant utility in a variety of applications. Potential applications include enhanced radiation signature identification of weapons components for nuclear disarmament and safeguards applications and augmented nondestructive analysis of spent nuclear fuel. In general, these techniques expand present capabilities in the analysis of subcritical measurements

  8. Measurement of acoustic characteristics of Japanese Buddhist temples in relation to sound source location and direction.

    Science.gov (United States)

    Soeta, Yoshiharu; Shimokura, Ryota; Kim, Yong Hee; Ohsawa, Tomohiro; Ito, Ken

    2013-05-01

    Although temples are important buildings in the Buddhist community, the acoustic quality has not been examined in detail. Buddhist monks change the location and direction according to the ceremony, and associated acoustical changes have not yet been examined scientifically. To discuss the desired acoustics of temples, it is necessary to know the acoustic characteristics appropriate for each phase of a ceremony. In this study, acoustic measurements were taken at various source locations and directions in Japanese temples. A directional loudspeaker was used as the source to provide vocal acoustic fields, and impulse responses were measured and analyzed. The speech transmission index was higher and the interaural cross-correlation coefficient was lower for the sound source directed toward the side wall than that directed toward the altar. This suggests that the change in direction improves speech intelligibility, and the asymmetric property of direct sound and complex reflections from the altar and side wall increases the apparent source width. The large and coupled-like structure of the altar of a Buddhist temple may have reinforced the reverberation components and the table in the altar, which is called the "syumidan," may have decreased binaural coherence.

  9. MEASURING THE UNDETECTABLE: PROPER MOTIONS AND PARALLAXES OF VERY FAINT SOURCES

    International Nuclear Information System (INIS)

    Lang, Dustin; Hogg, David W.; Jester, Sebastian; Rix, Hans-Walter

    2009-01-01

    The near future of astrophysics involves many large solid-angle, multi-epoch, multiband imaging surveys. These surveys will, at their faint limits, have data on a large number of sources that are too faint to be detected at any individual epoch. Here, we show that it is possible to measure in multi-epoch data not only the fluxes and positions, but also the parallaxes and proper motions of sources that are too faint to be detected at any individual epoch. The method involves fitting a model of a moving point source simultaneously to all imaging, taking account of the noise and point-spread function (PSF) in each image. By this method it is possible to measure the proper motion of a point source with an uncertainty close to the minimum possible uncertainty given the information in the data, which is limited by the PSF, the distribution of observation times (epochs), and the total signal-to-noise in the combined data. We demonstrate our technique on multi-epoch Sloan Digital Sky Survey (SDSS) imaging of the SDSS Southern Stripe (SDSSSS). We show that with our new technique we can use proper motions to distinguish very red brown dwarfs from very high-redshift quasars in these SDSS data, for objects that are inaccessible to traditional techniques, and with better fidelity than by multiband imaging alone. We rediscover all 10 known brown dwarfs in our sample and present nine new candidate brown dwarfs, identified on the basis of significant proper motion.

  10. Study of principle error sources in gamma spectrometry. Application to cross sections measurement

    International Nuclear Information System (INIS)

    Majah, M. Ibn.

    1985-01-01

    The principle error sources in gamma spectrometry have been studied in purpose to measure cross sections with great precision. Three error sources have been studied: dead time and pile up which depend on counting rate, and coincidence effect that depends on the disintegration scheme of the radionuclide in question. A constant frequency pulse generator has been used to correct the counting loss due to dead time and pile up in cases of long and short disintegration periods. The loss due to coincidence effect can reach 25% and over, depending on the disintegration scheme and on the distance source-detector. After establishing the correction formula and verifying its validity for four examples: iron 56, scandium 48, antimony 120 and gold 196 m, an application has been done by measuring cross sections of nuclear reactions that lead to long disintegration periods which need short distance source-detector counting and thus correcting the loss due to dead time effect, pile up and coincidence effect. 16 refs., 45 figs., 25 tabs. (author)

  11. Inversion of GPS-measured coseismic displacements for source parameters of Taiwan earthquake

    Science.gov (United States)

    Lin, J. T.; Chang, W. L.; Hung, H. K.; Yu, W. C.

    2016-12-01

    We performed a method of determining earthquake location, focal mechanism, and centroid moment tensor by coseismic surface displacements from daily and high-rate GPS measurements. Unlike commonly used dislocation model where fault geometry is calculated nonlinearly, our method makes a point source approach to evaluate these parameters in a solid and efficient way without a priori fault information and can thus provide constrains to subsequent finite source modeling of fault slip. In this study, we focus on the resolving ability of GPS data for moderate (Mw=6.0 7.0) earthquakes in Taiwan, and four earthquakes were investigated in detail: the March 27 2013 Nantou (Mw=6.0), the June 2 2013 Nantou (Mw=6.3) , the October 31 2013 Ruisui (Mw=6.3), and the March 31 2002 Hualien (ML=6.8) earthquakes. All these events were recorded by the Taiwan continuous GPS network with data sampling rates of 30-second and 1 Hz, where the Mw6.3 Ruisui earthquake was additionally recorded by another local GPS network with a sampling rate of 20 Hz. Our inverted focal mechanisms of all these earthquakes are consistent with the results of GCMT and USGS that evaluates source parameters by dynamic information from seismic waves. We also successfully resolved source parameters of the Mw6.3 Ruisui earthquake within only 10 seconds following the earthquake occurrence, demonstrating the potential of high-rate GPS data on earthquake early warning and real-time determination of earthquake source parameters.

  12. Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurements

    Science.gov (United States)

    Voutta, R.; Gerstl, S.; Casalbuoni, S.; Grau, A. W.; Holubek, T.; Saez de Jauregui, D.; Bartolini, R.; Cox, M. P.; Longhi, E. C.; Rehm, G.; Schouten, J. C.; Walker, R. P.; Migliorati, M.; Spataro, B.

    2016-05-01

    The beam heat load is an important input parameter needed for the cryogenic design of superconducting insertion devices. Theoretical models taking into account the different heating mechanisms of an electron beam to a cold bore predict smaller values than the ones measured with several superconducting insertion devices installed in different electron storage rings. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG) has been built. COLDDIAG is equipped with temperature sensors, pressure gauges, mass spectrometers as well as retarding field analyzers which allow to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. COLDDIAG was installed in a straight section of the Diamond Light Source (DLS). In a previous paper the experimental equipment as well as the installation of COLDDIAG in the DLS are described [S. Gerstl et al., Phys. Rev. ST Accel. Beams 17, 103201 (2014)]. In this paper we present an overview of all the measurements performed with COLDDIAG at the DLS and their detailed analysis, as well as impedance bench measurements of the cold beam vacuum chamber performed at the Karlsruhe Institute of Technology after removal from the DLS. Relevant conclusions for the cryogenic design of superconducting insertion devices are drawn from the obtained results.

  13. Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurements

    Directory of Open Access Journals (Sweden)

    R. Voutta

    2016-05-01

    Full Text Available The beam heat load is an important input parameter needed for the cryogenic design of superconducting insertion devices. Theoretical models taking into account the different heating mechanisms of an electron beam to a cold bore predict smaller values than the ones measured with several superconducting insertion devices installed in different electron storage rings. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG has been built. COLDDIAG is equipped with temperature sensors, pressure gauges, mass spectrometers as well as retarding field analyzers which allow to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. COLDDIAG was installed in a straight section of the Diamond Light Source (DLS. In a previous paper the experimental equipment as well as the installation of COLDDIAG in the DLS are described [S. Gerstl et al., Phys. Rev. ST Accel. Beams 17, 103201 (2014]. In this paper we present an overview of all the measurements performed with COLDDIAG at the DLS and their detailed analysis, as well as impedance bench measurements of the cold beam vacuum chamber performed at the Karlsruhe Institute of Technology after removal from the DLS. Relevant conclusions for the cryogenic design of superconducting insertion devices are drawn from the obtained results.

  14. Measuring the Plasma Density of a Ferroelectric Plasma Source in an Expanding Plasma

    International Nuclear Information System (INIS)

    Dunaevsky, A.; Fisch, N.J.

    2003-01-01

    The initial density and electron temperature at the surface of a ferroelectric plasma source were deduced from floating probe measurements in an expanding plasma. The method exploits negative charging of the floating probe capacitance by fast flows before the expanding plasma reaches the probe. The temporal profiles of the plasma density can be obtained from the voltage traces of the discharge of the charged probe capacitance by the ion current from the expanding plasma. The temporal profiles of the plasma density, at two different distances from the surface of the ferroelectric plasma source, could be further fitted by using the density profiles for the expanding plasma. This gives the initial values of the plasma density and electron temperature at the surface. The method could be useful for any pulsed discharge, which is accompanied by considerable electromagnetic noise, if the initial plasma parameters might be deduced from measurements in expanding plasma

  15. Measurement and calculation of radiation sources in the primary cooling system of JOYO

    International Nuclear Information System (INIS)

    Suzuki, S.; Iizawa, K.; Ohtani, N.; Kobayashi, T.; Horie, J.; Handa, H.

    1987-01-01

    Production and transfer of radiation sources in the primary cooling system are important consideration in the LMFBR plant from the viewpoint of radiation protection and shielding design. These items were evaluated with calculations and/or measurements in the Japanese experimental fast reactor JOYO. In this study, calculations were made with the DOT3.5 0 two-dimensional discrete ordinate transport code to determine the neutron flux and production rate distributions of radiation sources in the reactor vessel. Using the DOT results, the behavior in primary coolant sodium of the CP (radioactive corrosion products) which were released from the reactor structural material was also calculationally analyzed with the PSYCHE code developed by PNC. These analytical results were compared with the measured results to get the verification of analysis methods and to estimate the accuracy of calculations

  16. Understanding data sources to measure patient retention in HIV care in sub-Saharan Africa.

    Science.gov (United States)

    Clouse, Kate; Phillips, Tamsin; Myer, Landon

    2017-07-01

    Antiretroviral therapy (ART) programs in sub-Saharan Africa are moving towards universal treatment, yet the success of these programs is threatened by gaps within the continuum of HIV care. In this commentary, we seek to draw attention to the advantages and limitations of different data sources currently used for measuring retention in HIV care. Within the context of a piecemeal combination of imperfect data sources, selecting a gold standard of collecting retention data is difficult. Currently, our data systems for measuring retention provide an incomplete picture of the health of our national ART systems and, thus, the health of our patients. © The Author 2017. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Acoustical source reconstruction from non-synchronous sequential measurements by Fast Iterative Shrinkage Thresholding Algorithm

    Science.gov (United States)

    Yu, Liang; Antoni, Jerome; Leclere, Quentin; Jiang, Weikang

    2017-11-01

    Acoustical source reconstruction is a typical inverse problem, whose minimum frequency of reconstruction hinges on the size of the array and maximum frequency depends on the spacing distance between the microphones. For the sake of enlarging the frequency of reconstruction and reducing the cost of an acquisition system, Cyclic Projection (CP), a method of sequential measurements without reference, was recently investigated (JSV,2016,372:31-49). In this paper, the Propagation based Fast Iterative Shrinkage Thresholding Algorithm (Propagation-FISTA) is introduced, which improves CP in two aspects: (1) the number of acoustic sources is no longer needed and the only making assumption is that of a "weakly sparse" eigenvalue spectrum; (2) the construction of the spatial basis is much easier and adaptive to practical scenarios of acoustical measurements benefiting from the introduction of propagation based spatial basis. The proposed Propagation-FISTA is first investigated with different simulations and experimental setups and is next illustrated with an industrial case.

  18. Measurement of thermal conductivity of uranium metal using transient plane source technique

    International Nuclear Information System (INIS)

    Subramanian, G.G.S.; Bapuji, T.; Panneerselvam, G.; Antony, M.P.; Nagarajan, K.

    2012-01-01

    Thermo physical properties of fuel, cladding and structural materials play a significant role in the reactor operation. Thermal conductivity is one of the most important physical properties of the fuel which determines the maximum linear heat rating of the fuel in a reactor. As part of this study, the thermal conductivity of uranium metal was measured using a transient plane source (TPS) by Hot-disc method

  19. X-ray stress measurement by use of synchrotron radiation source

    International Nuclear Information System (INIS)

    Yoshioka, Yasuo; Matsui, Hisaaki; Moro-oka, Toshimasa; Hasegawa, Ken-ichi; Nakajima, Tetsuo.

    1986-01-01

    In the field of X-ray stress measurement of polycrystalline materials, a diffraction plane at higher Bragg angle has to be selected in order to obtain the precise value of stress. However, the stress measurement on an optional (hkl) plane desired is not always possible because the X-ray beam exited from a metal target has a dispersive wave length. Recently, we have been able to use the synchrotron radiation source (SR) as an excellent X-ray source. In Japan, the facility of synchrotron radiation (Photon Factory, PF) was constructed in the National Laboratory for High Energy Physics (KEK) at Tsukuba academic city. The use of this SR enables the stress measurements on many (hkl) planes with high accuracy in the higher Bragg angle region by providing an X-ray beam having an optional wave length. We have started the X-ray stress analysis by use of the synchrotron radiation source. This paper reports the system of measurement and some results of preliminaly experiments. Since a monochromatic X-ray beam is required for the stress measurement, we used a beam line which consists of a double crystal monochrometer and a focusing mirror. X-rays between 4 KeV (λ = 0.31 nm) and 10 KeV (λ = 0.12 nm) are available with this optical system. We adopted a constant Bragg angle of 2θ = 154 deg for all the diffraction planes. A PSPC having a carbon fiber anode is made and used as a detector with the use of a fast digital signal processor. We could observe the diffraction profiles from (200), (211), (220), (310) and (321) crystal plane of alpha iron, respectively, and the residual stresses in these planes except the (200) plane were measured with high accuracy in a short time. Such feature especially suits the stress analysis of the material which has preferred orientation or stress gradient. (author)

  20. The Dynamic Method for Time-of-Flight Measurement of Thermal Neutron Spectra from Pulsed Sources

    International Nuclear Information System (INIS)

    Pepelyshev, Yu.N.; Tulaev, A.B.; Bobrakov, V.F.

    1994-01-01

    The time-of-flight method for a measurement of thermal neutron spectra in the pulsed neutron sources with high efficiency of neutron registration, more than 10 5 times higher in comparison with traditional one, is described. The main problems connected with the electric current technique for time-of-flight spectra measurement are examined. The methodical errors, problems of a special neutron detector design and other questions are discussed. Some experimental results, spectra from surfaces of the water and solid methane moderators, obtained in the pulsed reactor IBR-2 (Dubna, Russia) are presented. 4 refs., 5 figs

  1. A fission ionization detector for neutron flux measurements at a spallation source

    Energy Technology Data Exchange (ETDEWEB)

    Wender, S.A. (Los Alamos National Lab., Los Alamos, NM (United States)); Balestrini, S. (Los Alamos National Lab., Los Alamos, NM (United States)); Brown, A. (Los Alamos National Lab., Los Alamos, NM (United States)); Haight, R.C. (Los Alamos National Lab., Los Alamos, NM (United States)); Laymon, C.M. (Los Alamos National Lab., Los Alamos, NM (United States)); Lee, T.M. (Los Alamos National Lab., Los Alamos, NM (United States)); Lisowski, P.W. (Los Alamos National Lab., Los Alamos, NM (United States)); McCorkle, W. (Los Alamos National Lab., Los Alamos, NM (United States)); Nelson, R.O. (Los Alamos National Lab., Los Alamos, NM (United States)); Parker, W. (Los Alamos National Lab., Los Alamos, NM (United States)); Hill, N.W. (Oak Ridge National Lab., Oak Ridge, TN (United States))

    1993-11-15

    The construction of a neutron flux monitor that can measure absolute neutron intensities in the neutron energy range from below 1 MeV to over 500 MeV is described. The detector consists of an ionization chamber with several thin deposits of fissionable material. The ionization chamber is thin enough that it does not significantly affect the neutron beam and may be left in the neutron flight path during experimental measurements to continuously monitor the beam flux. The use of this monitor at the continuous-energy spallation neutron source at the WNR target area at LAMPF is described. (orig.)

  2. A fission ionization detector for neutron flux measurements at a spallation source

    International Nuclear Information System (INIS)

    Wender, S.A.; Balestrini, S.; Brown, A.; Haight, R.C.; Laymon, C.M.; Lee, T.M.; Lisowski, P.W.; McCorkle, W.; Nelson, R.O.; Parker, W.; Hill, N.W.

    1993-01-01

    The construction of a neutron flux monitor that can measure absolute neutron intensities in the neutron energy range from below 1 MeV to over 500 MeV is described. The detector consists of an ionization chamber with several thin deposits of fissionable material. The ionization chamber is thin enough that it does not significantly affect the neutron beam and may be left in the neutron flight path during experimental measurements to continuously monitor the beam flux. The use of this monitor at the continuous-energy spallation neutron source at the WNR target area at LAMPF is described. (orig.)

  3. Electron Source Brightness and Illumination Semi-Angle Distribution Measurement in a Transmission Electron Microscope.

    Science.gov (United States)

    Börrnert, Felix; Renner, Julian; Kaiser, Ute

    2018-05-21

    The electron source brightness is an important parameter in an electron microscope. Reliable and easy brightness measurement routes are not easily found. A determination method for the illumination semi-angle distribution in transmission electron microscopy is even less well documented. Herein, we report a simple measurement route for both entities and demonstrate it on a state-of-the-art instrument. The reduced axial brightness of the FEI X-FEG with a monochromator was determined to be larger than 108 A/(m2 sr V).

  4. The dynamic method for time-of-flight measurement of thermal neutron spectra from pulsed sources

    International Nuclear Information System (INIS)

    Pepyolyshev, Yu.N.; Chuklyaev, S.V.; Tulaev, A.B.; Bobrakov, V.F.

    1995-01-01

    A time-of-flight method for measurement of thermal neutron spectra in pulsed neutron sources with an efficiency more than 10 5 times higher than the standard method is described. The main problems associated with the electric current technique for time-of-flight spectra measurement are examined. The methodical errors, problems of special neutron detector design and other questions are discussed. Some experimental results for spectra from the surfaces of water and solid methane moderators obtained at the IBR-2 pulsed reactor (Dubna, Russia) are presented. (orig.)

  5. Ion source plasma parameters measurement based on Langmuir probe with commercial frequency sweep

    International Nuclear Information System (INIS)

    Xie, Y.H.; Hu, C.D.; Liu, S.; Shong, S.H.; Jiang, C.C.; Liu, Z.M.

    2010-01-01

    Langmuir probe is one of the main diagnostic tools to measure the plasma parameters in the ion source. In this article, the commercial frequency power, which is sine wave of 50 Hz, was supplied on the Langmuir probe to measure the plasma parameters. The best feature of this probe sweep voltage is that it does not need extra design. The probe I-V characteristic curve can be got in less than 5 ms and the plasma parameters, the electron temperature and the electron density, varying with the time can be got in one plasma discharge of 400 ms.

  6. Apportionment of urban aerosol sources in Cork (Ireland) by synergistic measurement techniques.

    Science.gov (United States)

    Dall'Osto, Manuel; Hellebust, Stig; Healy, Robert M; O'Connor, Ian P; Kourtchev, Ivan; Sodeau, John R; Ovadnevaite, Jurgita; Ceburnis, Darius; O'Dowd, Colin D; Wenger, John C

    2014-09-15

    The sources of ambient fine particulate matter (PM2.5) during wintertime at a background urban location in Cork city (Ireland) have been determined. Aerosol chemical analyses were performed by multiple techniques including on-line high resolution aerosol time-of-flight mass spectrometry (Aerodyne HR-ToF-AMS), on-line single particle aerosol time-of-flight mass spectrometry (TSI ATOFMS), on-line elemental carbon-organic carbon analysis (Sunset_EC-OC), and off-line gas chromatography/mass spectrometry and ion chromatography analysis of filter samples collected at 6-h resolution. Positive matrix factorization (PMF) has been carried out to better elucidate aerosol sources not clearly identified when analyzing results from individual aerosol techniques on their own. Two datasets have been considered: on-line measurements averaged over 2-h periods, and both on-line and off-line measurements averaged over 6-h periods. Five aerosol sources were identified by PMF in both datasets, with excellent agreement between the two solutions: (1) regional domestic solid fuel burning--"DSF_Regional," 24-27%; (2) local urban domestic solid fuel burning--"DSF_Urban," 22-23%; (3) road vehicle emissions--"Traffic," 15-20%; (4) secondary aerosols from regional anthropogenic sources--"SA_Regional" 9-13%; and (5) secondary aged/processed aerosols related to urban anthropogenic sources--"SA_Urban," 21-26%. The results indicate that, despite regulations for restricting the use of smoky fuels, solid fuel burning is the major source (46-50%) of PM2.5 in wintertime in Cork, and also likely other areas of Ireland. Whilst wood combustion is strongly associated with OC and EC, it was found that peat and coal combustion is linked mainly with OC and the aerosol from these latter sources appears to be more volatile than that produced by wood combustion. Ship emissions from the nearby port were found to be mixed with the SA_Regional factor. The PMF analysis allowed us to link the AMS cooking organic

  7. Design of x-ray diagnostic beam line for a synchrotron radiation source and measurement results

    Energy Technology Data Exchange (ETDEWEB)

    Garg, Akash Deep, E-mail: akash-deep@rrcat.gov.in; Karnewar, A.K.; Ojha, A.; Shrivastava, B.B.; Holikatti, A.C.; Puntambekar, T.A.; Navathe, C.P.

    2014-08-01

    Indus-2 is a 2.5 GeV synchrotron radiation source (SRS) operational at the Raja Ramanna Centre for Advanced Technology (RRCAT) in India. We have designed, developed and commissioned x-ray diagnostic beam line (X-DBL) at the Indus-2. It is based on pinhole array imaging (8–18 keV). We have derived new equations for online measurements of source position and emission angle with pinhole array optics. Measured values are compared with the measurements at an independent x-ray beam position monitor (staggered pair blade monitor) installed in the X-DBL. The measured values are close to the theoretical expected values within ±12 µm (or ±1.5 μrad) for sufficiently wide range of the beam movements. So, beside the beam size and the beam emittance, online information for the vertical position and angle is also used in the orbit steering. In this paper, the various design considerations of the X-DBL and online measurement results are presented.

  8. EMF Rapid Program Engineering Projects, Project 1, Development of Recommendations for Guidelines for Field Source Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Electric Research and Management, Inc.

    1997-03-11

    The goal of this project is to develop a protocol for measuring the electric and magnetic fields around sources. Data from these measurements may help direct future biological effects research by better defining the complexity of magnetic and electric fields to which humanity is exposed, as well asprovide the basis for rigorous field exposure analysis and risk assessment once the relationship between field exposure and biological response. is better understood. The data base also should have sufficient spatial and temporal characteristics to guide electric and magnetic field management. The goal of Task A is to construct a set of characteristics that would be ideal to have for guiding and interpreting biological studies and for focusing any future effort at field management. This ideal set will then be quantified and reduced according to the availability (or possible development of) instrumentation to measure the desired characteristics. Factors that also will be used to define pragmatic data sets will be the cost of collecting the data, the cost of developing an adequate data base, and the needed precision in measuring specific characteristics. A field, electric or magnetic, will always be ,some function of time and space. The first step in this section of the protocol development will be to determine what span of time and what portion of space are required to quantify the electric and magnetic fields around sources such as appliances and electrical apparatus. Constraints on time will be set by examining measurement limitations and biological data requirements.

  9. Transverse Beam Halo Measurements at High Intensity Neutrino Source (HINS) using Vibrating Wire Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, M.; Hanna, B.; Scarpine, V.; Shiltsev, V.; Steimel, J.; Artinian, S.; Arutunian, S.

    2015-02-26

    The measurement and control of beam halos will be critical for the applications of future high-intensity hadron linacs. In particular, beam profile monitors require a very high dynamic range when used for the transverse beam halo measurements. In this study, the Vibrating Wire Monitor (VWM) with aperture 60 mm was installed at the High Intensity Neutrino Source (HINS) front-end to measure the transverse beam halo. A vibrating wire is excited at its resonance frequency with the help of a magnetic feedback loop, and the vibrating and sensitive wires are connected through a balanced arm. The sensitive wire is moved into the beam halo region by a stepper motor controlled translational stage. We study the feasibility of the vibrating wire for the transverse beam halo measurements in the low-energy front-end of the proton linac.

  10. Oceans circulation and electron cyclotron resonance sources: Measurement of the AR-39 isotopic ratio in Seawater

    International Nuclear Information System (INIS)

    Gaelens, M.; Loiselet, M.; Ryckewaert, G.; Pardo, R.C.; Scott, R.H.; Vondrasek, R.; Collon, Ph.; Kutchera, W.

    2004-01-01

    The radionuclide 39 Ar is produced in the atmosphere by cosmic rays and has an isotopic abundance of 8.1x10 -16 . Because its half life (T 1/2 =269 years) is well matched to the time periods involved in the oceanic currents around the Earth, the measurement of the 39 Ar isotopic ratio is an ideal tool to date ocean water from different depths. It would complement the information gained by the 14 C measurements (T 1/2 =5730 years). However, the measurement of the isotopic ratio 39 Ar/ 40 Ar is a technical challenge: 1 L of modern ocean water contains ∼6500 atoms of 39 Ar, and produces ∼17 decays per year. Although it has been possible to detect the 39 Ar decays in large volumes of sea water by using the low level counting technique, the possibility of measuring the number of 39 Ar atoms faster and in smaller samples using the accelerator mass spectrometry (AMS) technique would be a major breakthrough for this type of measurement. The development of a viable AMS method for 39 Ar has been underway for several years at Argonne National Laboratory, and is presently hampered by the presence of stable 39 K ions coming from the ion source. Although the intensity of this isobaric contaminant is low (∼pA extracted from the source), it has to be compared with the 39 Ar beam intensity (atoms per minutes). In order to separate these two beams (whose mass difference is only 1.6x10 -5 ), the intensity of the 39 K beam coming from the ion source has to be reduced by several orders of magnitude. This reduction has been investigated both at Argonne National Laboratory and at Louvain-la-Neuve. Two techniques have been tried out. In the first, a quartz liner is used to provide a clean surface, while in the second these impurities are buried in a SiO 2 layer formed in situ by running the source with a mixture of silane and oxygen. The 39 K background has been reduced by a factor of 100 with these treatments. These techniques and their results obtained both at Argonne and Louvain

  11. Moving gantry method for electron beam dose profile measurement at extended source-to-surface distances.

    Science.gov (United States)

    Fekete, Gábor; Fodor, Emese; Pesznyák, Csilla

    2015-03-08

    A novel method has been put forward for very large electron beam profile measurement. With this method, absorbed dose profiles can be measured at any depth in a solid phantom for total skin electron therapy. Electron beam dose profiles were collected with two different methods. Profile measurements were performed at 0.2 and 1.2 cm depths with a parallel plate and a thimble chamber, respectively. 108cm × 108 cm and 45 cm × 45 cm projected size electron beams were scanned by vertically moving phantom and detector at 300 cm source-to-surface distance with 90° and 270° gantry angles. The profiles collected this way were used as reference. Afterwards, the phantom was fixed on the central axis and the gantry was rotated with certain angular steps. After applying correction for the different source-to-detector distances and incidence of angle, the profiles measured in the two different setups were compared. Correction formalism has been developed. The agreement between the cross profiles taken at the depth of maximum dose with the 'classical' scanning and with the new moving gantry method was better than 0.5 % in the measuring range from zero to 71.9 cm. Inverse square and attenuation corrections had to be applied. The profiles measured with the parallel plate chamber agree better than 1%, except for the penumbra region, where the maximum difference is 1.5%. With the moving gantry method, very large electron field profiles can be measured at any depth in a solid phantom with high accuracy and reproducibility and with much less time per step. No special instrumentation is needed. The method can be used for commissioning of very large electron beams for computer-assisted treatment planning, for designing beam modifiers to improve dose uniformity, and for verification of computed dose profiles.

  12. Composition and Sources of Particulate Matter Measured near Houston, TX: Anthropogenic-Biogenic Interactions

    Directory of Open Access Journals (Sweden)

    Jeffrey K. Bean

    2016-05-01

    Full Text Available Particulate matter was measured in Conroe, Texas (~60 km north of downtown Houston, Texas during the September 2013 DISCOVER-AQ campaign to determine the sources of particulate matter in the region. The measurement site is influenced by high biogenic emission rates as well as transport of anthropogenic pollutants from the Houston metropolitan area and is therefore an ideal location to study anthropogenic-biogenic interactions. Data from an Aerosol Chemical Speciation Monitor (ACSM suggest that on average 64 percent of non-refractory PM1 was organic material, including a high fraction (27%–41% of organic nitrates. There was little diurnal variation in the concentrations of ammonium sulfate; however, concentrations of organic and organic nitrate aerosol were consistently higher at night than during the day. Potential explanations for the higher organic aerosol loadings at night include changing boundary layer height, increased partitioning to the particle phase at lower temperatures, and differences between daytime and nighttime chemical processes such as nitrate radical chemistry. Positive matrix factorization was applied to the organic aerosol mass spectra measured by the ACSM and three factors were resolved—two factors representing oxygenated organic aerosol and one factor representing hydrocarbon-like organic aerosol. The factors suggest that the measured aerosol was well mixed and highly processed, consistent with the distance from the site to major aerosol sources, as well as the high photochemical activity.

  13. Measurements of gamma-ray dose from a moderated 252Cf source

    International Nuclear Information System (INIS)

    McDonald, J.C.; Griffith, R.V.; Plato, P.; Miklos, J.

    1983-06-01

    The gamma-ray dose fraction from a moderated 252 Cf source was determined by using three types of dosimetry systems. Measurements were carried out in air at a distance of 35 cm from the surface of the moderating sphere (50 cm from the source which is at the center of the sphere) to the geometrical center of each detector. The moderating sphere is 0.8-mm-thick stainless steel shell filled with D 2 O and covered with 0.5 mm of cadmium. Measurements were also carried out with instruments and dosimeters positioned at the surface of a 40 cm x 40 cm x 15 cm plexiglass irradiation phantom whose front surface was also 35 cm from the surface of the moderating sphere. A-150 tissue-equivalent (TE) plastic ionization chambers and a TE proportional counter (TEPC) were used to measure tissue dose, from which the neutron dose equivalent was computed. The ratio of gamma-ray dose to the neutron dose equivalent was determined by using a relatively neutron-insensitive Geiger-Mueller (GM) counter and thermoluminescent dosimeters (TLD). In addition, the event-size spectrum measured by the TEPC was also used to compute the gamma-ray dose fraction. The average value for the ratio of gamma-ray dose to neutron dose equivalent was found to be 0.18 with an uncertainty of about +-18%

  14. Measurements of the cesium flow from a surface-plasma H- ion source

    International Nuclear Information System (INIS)

    Smith, H.V.; Allison, P.W.

    1979-01-01

    A surface ionization gauge (SIG) was constructed and used to measure the Cs 0 flow rate through the emission slit of a surface-plasma source (SPS) of H - ions with Penning geometry. The equivalent cesium density in the SPS discharge is deduced from these flow measurements. For dc operation the optimum H - current occurs at an equivalent cesium density of approx. 7 x 10 12 cm -3 (corresponding to an average cesium consumption rate of 0.5 mg/h). For pulsed operation the optimum H - current occurs at an equivalent cesium density of approx. 2 x 10 13 cm -3 (1-mg/h average cesium consumption rate). Cesium trapping by the SPS discharge was observed for both dc and pulsed operation. A cesium energy of approx. 0.1 eV is deduced from the observed time of flight to the SIG. In addition to providing information on the physics of the source, the SIG is a useful diagnostic tool for source startup and operation

  15. World energy consumption 1800-2000: definitions and measurements, information sources, results

    International Nuclear Information System (INIS)

    Martin-Amouroux, Jean-Marie

    2015-10-01

    A first article discusses definitions and measurements used to assess world energy consumption, notably the differences between primary, secondary, final and useful levels. The author identifies the different sources of primary energies (endo-somatic and exo-somatic), the various measurement units, and the spatial organisation of consumption statistics (national data bases, regional consolidations). The second article comments the available sources of information and their history (existing long chronological series at the world scale before and after World War 2), presents the evolution of world energy consumption according to Palmer Putnam, indicates and comments national studies on energy consumption for very long periods (USA, UK, France, and other countries). Then the author discusses the assessment of non commercial consumptions. He mentions and comments studies performed in the USA, in France, in Italy and in other countries, and also some assessments of biomass consumption. He finally discusses the availability of statistics on the evolution of world population. The third article presents and comments results obtained for the evolution of world consumption (world consumption per source of primary energy, per region) for the evolution of energy consumption in Africa, in Northern America, in Latin America, in Asia, in Russia and Eastern Europe and in Western Europe since 1800. Tables give these evolutions for coal, oil, natural gas, electricity, and biomass

  16. Investigation of particle transport through the measurement of the electron source in the Texas Experimental Tokamak

    International Nuclear Information System (INIS)

    Klepper, C.C.

    1985-01-01

    The spatial distribution of the electron source was measured spectroscopically in the Texas Experimental Tokamak. The method used involves the measurement of the emissivity of the Balmer α and β lines of neutral hydrogen. Modeling of the corresponding atomic transitions provides a relation between the emissivities and the electron source from the ionization of neutrals. Toroidal distributions were obtained by means of a set of relatively calibrated photodiode amplifier-filter packages referred to as plasma light monitors. Such monitors were distributed toroidally, and attached primarily to radial ports. Specially constructed, absolutely calibrated monitors provided absolute calibration. A scanning, rotating mirror system provided in-out brightness profiles. A TV camera system, viewing the limiter through a tangential port, provided a qualitative description of the poloidal asymmetry. Such description was necessary for the inversion of the rotating mirror data. Using electron density profiles obtained by means of far-infrared interferometry, and integrating the electron sources, the global particle confinement time (tau/sub p/) was computed. Parameter scans were performed in ohmically heated plasmas, varying the toroidal field, the plasma current, the electron density, and the plasma position with respect to the center of the poloidal ring limiter. It was found that tau/sub p/ peaks for a critical density that is independent of the other parameters

  17. Target-ion source unit ionization efficiency measurement by method of stable ion beam implantation

    CERN Document Server

    Panteleev, V.N; Fedorov, D.V; Moroz, F.V; Orlov, S.Yu; Volkov, Yu.M

    The ionization efficiency is one of the most important parameters of an on-line used target-ion source system exploited for production of exotic radioactive beams. The ionization efficiency value determination as a characteristic of a target-ion source unit in the stage of its normalizing before on-line use is a very important step in the course of the preparation for an on-line experiment. At the IRIS facility (Petersburg Nuclear Physics Institute, Gatchina) a reliable and rather precise method of the target-ion source unit ionization efficiency measurement by the method of stable beam implantation has been developed. The method worked out exploits an off-line mass-separator for the implantation of the ion beams of selected stable isotopes of different elements into a tantalum foil placed inside the Faraday cup in the focal plane of the mass-separator. The amount of implanted ions has been measured with a high accuracy by the current integrator connected to the Faraday cup. After the implantation of needed a...

  18. Inverse modeling of the Chernobyl source term using atmospheric concentration and deposition measurements

    Science.gov (United States)

    Evangeliou, Nikolaos; Hamburger, Thomas; Cozic, Anne; Balkanski, Yves; Stohl, Andreas

    2017-07-01

    This paper describes the results of an inverse modeling study for the determination of the source term of the radionuclides 134Cs, 137Cs and 131I released after the Chernobyl accident. The accident occurred on 26 April 1986 in the Former Soviet Union and released about 1019 Bq of radioactive materials that were transported as far away as the USA and Japan. Thereafter, several attempts to assess the magnitude of the emissions were made that were based on the knowledge of the core inventory and the levels of the spent fuel. More recently, when modeling tools were further developed, inverse modeling techniques were applied to the Chernobyl case for source term quantification. However, because radioactivity is a sensitive topic for the public and attracts a lot of attention, high-quality measurements, which are essential for inverse modeling, were not made available except for a few sparse activity concentration measurements far from the source and far from the main direction of the radioactive fallout. For the first time, we apply Bayesian inversion of the Chernobyl source term using not only activity concentrations but also deposition measurements from the most recent public data set. These observations refer to a data rescue attempt that started more than 10 years ago, with a final goal to provide available measurements to anyone interested. In regards to our inverse modeling results, emissions of 134Cs were estimated to be 80 PBq or 30-50 % higher than what was previously published. From the released amount of 134Cs, about 70 PBq were deposited all over Europe. Similar to 134Cs, emissions of 137Cs were estimated as 86 PBq, on the same order as previously reported results. Finally, 131I emissions of 1365 PBq were found, which are about 10 % less than the prior total releases. The inversion pushes the injection heights of the three radionuclides to higher altitudes (up to about 3 km) than previously assumed (≈ 2.2 km) in order to better match both concentration

  19. Inverse modeling of the Chernobyl source term using atmospheric concentration and deposition measurements

    Directory of Open Access Journals (Sweden)

    N. Evangeliou

    2017-07-01

    Full Text Available This paper describes the results of an inverse modeling study for the determination of the source term of the radionuclides 134Cs, 137Cs and 131I released after the Chernobyl accident. The accident occurred on 26 April 1986 in the Former Soviet Union and released about 1019 Bq of radioactive materials that were transported as far away as the USA and Japan. Thereafter, several attempts to assess the magnitude of the emissions were made that were based on the knowledge of the core inventory and the levels of the spent fuel. More recently, when modeling tools were further developed, inverse modeling techniques were applied to the Chernobyl case for source term quantification. However, because radioactivity is a sensitive topic for the public and attracts a lot of attention, high-quality measurements, which are essential for inverse modeling, were not made available except for a few sparse activity concentration measurements far from the source and far from the main direction of the radioactive fallout. For the first time, we apply Bayesian inversion of the Chernobyl source term using not only activity concentrations but also deposition measurements from the most recent public data set. These observations refer to a data rescue attempt that started more than 10 years ago, with a final goal to provide available measurements to anyone interested. In regards to our inverse modeling results, emissions of 134Cs were estimated to be 80 PBq or 30–50 % higher than what was previously published. From the released amount of 134Cs, about 70 PBq were deposited all over Europe. Similar to 134Cs, emissions of 137Cs were estimated as 86 PBq, on the same order as previously reported results. Finally, 131I emissions of 1365 PBq were found, which are about 10 % less than the prior total releases. The inversion pushes the injection heights of the three radionuclides to higher altitudes (up to about 3 km than previously assumed (≈ 2.2 km in order

  20. (CH4)-C-14 Measurements in Greenland Ice: Investigating Last Glacial Termination CH4 Sources

    DEFF Research Database (Denmark)

    Petrenko, V. V.; Smith, A. M.; Brook, E. J.

    2009-01-01

    by direct cosmogenic C-14 production in ice. C-14 of CO was measured to better understand this process and correct the sample (CH4)-C-14. Corrected results suggest that wetland sources were likely responsible for the majority of the Younger Dryas-Preboreal CH4 rise.......The cause of a large increase of atmospheric methane concentration during the Younger Dryas-Preboreal abrupt climatic transition (similar to 11,600 years ago) has been the subject of much debate. The carbon-14 (C-14) content of methane ((CH4)-C-14) should distinguish between wetland and clathrate...... contributions to this increase. We present measurements of (CH4)-C-14 in glacial ice, targeting this transition, performed by using ice samples obtained from an ablation site in west Greenland. Measured (CH4)-C-14 values were higher than predicted under any scenario. Sample (CH4)-C-14 appears to be elevated...

  1. Measurement of minority carrier lifetime in silicon solar cells using an a. c. light source

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, A.; Gupta, R.S.; Srivastava, G.P. (Delhi Univ., New Delhi (India). Dept. of Electronic Sciences); Jain, V.K. (Solid State Physics Lab., Delhi (India)); Chilana, G.S. (Delhi Univ. (India). Dept. of Physics and Astrophysics)

    1990-06-01

    A simple technique for the measurement of minority carriers lifetimes is proposed. It is based on the modification of the junction structure by the addition of a d.c. bias to the a.c. source. This always keeps the solar cell in the forward biased condition and also keeps it in the operating range. This method provides a direct measurement of minority carriers lifetimes. The lifetime is found to increase from 2.89 {mu}s at 30deg C to 4.55 {mu}s at 120deg C. The lifetime reduces to 1.45 {mu}s at liquid air temperature. Based on these lifetime measurements, the diffusion length of the carriers has also been calculated. (orig.).

  2. Resistive plate chamber neutron and gamma sensitivity measurement with a {sup 252}Cf source

    Energy Technology Data Exchange (ETDEWEB)

    Abbrescia, M.; Altieri, S.; Baratti, V.; Barnaba, O.; Belli, G.; Bruno, G.; Colaleo, A.; DeVecchi, C.; Guida, R. E-mail: roberto.guida@pv.infn.it; Iaselli, G.; Imbres, E.; Loddo, F.; Maggi, M.; Marangelli, B.; Musitelli, G.; Nardo, R.; Natali, S.; Nuzzo, S.; Pugliese, G.; Ranieri, A.; Ratti, S.; Riccardi, C.; Romano, F.; Torre, P.; Vicini, A.; Vitulo, P.; Volpe, F

    2003-06-21

    A bakelite double gap Resistive Plate Chamber (RPC), operating in avalanche mode, has been exposed to the radiation emitted from a {sup 252}Cf source to measure its neutron and gamma sensitivity. One of the two gaps underwent the traditional electrodes surface coating with linseed oil. RPC signals were triggered by fission events detected using BaF{sub 2} scintillators. A Monte Carlo code, inside the GEANT 3.21 framework with MICAP interface, has been used to identify the gamma and neutron contributions to the total number of collected RPC signals. A neutron sensitivity of (0.63{+-}0.02)x10{sup -3} (average energy 2 MeV) and a gamma sensitivity of (14.0{+-}0.5)x10{sup -3} (average energy 1.5 MeV) have been measured in double gap mode. Measurements done in single gap mode have shown that both neutron and gamma sensitivity are independent of the oiling treatment.

  3. An experiment to measure the electron neutrino mass using a cryogenic tritium source

    International Nuclear Information System (INIS)

    Fackler, O.; Jeziorski, B.; Kolos, W.; Monkhorst, H.; Mugge, M.; Sticker, H.; Szalewicz, K.; White, R.M.; Woerner, R.

    1985-01-01

    An experiment has been performed to determine the electron neutrino mass with the precision of a few eV by measuring the tritium beta decay energy distribution near the endpoint. Key features of the experiment are a 2 eV resolution electrostatic spectrometer and a high-activity frozen tritium source. It is important that the source have electronic wavefunctions which can be accurately calculated. These calculations have been made for tritium and the HeT + daughter ion and allow determination of branching fractions to 0.1% and energy of the excited states to 0.1 eV. The excited final molecular state calculations and the experimental apparatus are discussed. 4 refs., 5 figs

  4. Contribution to the study of luminous sources for uranium isotope measurements by emission spectrometry

    International Nuclear Information System (INIS)

    Leichnam, J.P.; Capitini, R.

    1964-01-01

    After a brief summary of results obtained with different hollow cathode luminous sources, the reasons for which they cannot be more widely used are given: an insufficient luminosity when uranium oxides are used in the cathode hollow; the large amount of sample required when it is metallic; the impossibility of effecting a chemical purification of the sample. Electrode-less discharge tubes excited by high frequency whose qualities (luminosity, stability, rapidity of preparation starting from small amounts of sample in various chemical forms, in particular iron) satisfy the conditions laid down for the measurement of uranium 235 by interferometry are used. Tho production process for such lamps is given together with the method of excitation. Examples of recordings obtained with an interferometer of the 'HYPEAC' type and a small grating spectrometer give an idea of the spectral qualities of these sources. (authors) [fr

  5. A new ion source for fission-yield measurements of rare-earth isotopes

    International Nuclear Information System (INIS)

    Pilzer, E.H.; Engler, G.

    1987-01-01

    A new integrated target-ion source for fission-yield measurements of rare-earth isotopes has been developed for the Soreq on-line isotope separator (SOLIS). The source is heated by electron bombardment to a temperature of 2400 0 C and ionization takes place in a rhenium hot cavity. To overcome the problem of impurities which reduce the ionization efficiency, a ZrC disk was inserted in the cavity. Calculations show that because of its high thermionic emission, ZrC enhances ionization performance considerably. For example, in the presence of 10 -5 mbar of cesium impurity, the ionization efficiency of a rhenium hot cavity for the rare-earth terbium is 6%. However, with a ZrC disk, the efficiency increases to 97%. (orig.)

  6. Tropical forests are a net carbon source based on aboveground measurements of gain and loss

    Science.gov (United States)

    Baccini, A.; Walker, W.; Carvalho, L.; Farina, M.; Sulla-Menashe, D.; Houghton, R. A.

    2017-10-01

    The carbon balance of tropical ecosystems remains uncertain, with top-down atmospheric studies suggesting an overall sink and bottom-up ecological approaches indicating a modest net source. Here we use 12 years (2003 to 2014) of MODIS pantropical satellite data to quantify net annual changes in the aboveground carbon density of tropical woody live vegetation, providing direct, measurement-based evidence that the world’s tropical forests are a net carbon source of 425.2 ± 92.0 teragrams of carbon per year (Tg C year-1). This net release of carbon consists of losses of 861.7 ± 80.2 Tg C year-1 and gains of 436.5 ± 31.0 Tg C year-1. Gains result from forest growth; losses result from deforestation and from reductions in carbon density within standing forests (degradation or disturbance), with the latter accounting for 68.9% of overall losses.

  7. Chemical characterization and source apportionment of submicron aerosols measured in Senegal during the 2015 SHADOW campaign

    Science.gov (United States)

    Rivellini, Laura-Hélèna; Chiapello, Isabelle; Tison, Emmanuel; Fourmentin, Marc; Féron, Anaïs; Diallo, Aboubacry; N'Diaye, Thierno; Goloub, Philippe; Canonaco, Francesco; Prévôt, André Stephan Henry; Riffault, Véronique

    2017-09-01

    The present study offers the first chemical characterization of the submicron (PM1) fraction in western Africa at a high time resolution, thanks to collocated measurements of nonrefractory (NR) species with an Aerosol Chemical Speciation Monitor (ACSM), black carbon and iron concentrations derived from absorption coefficient measurements with a 7-wavelength Aethalometer, and total PM1 determined by a TEOM-FDMS (tapered element oscillating microbalance-filtered dynamic measurement system) for mass closure. The field campaign was carried out over 3 months (March to June 2015) as part of the SHADOW (SaHAran Dust Over West Africa) project at a coastal site located in the outskirts of the city of Mbour, Senegal. With an averaged mass concentration of 5.4 µg m-3, levels of NR PM1 in Mbour were 3 to 10 times lower than those generally measured in urban and suburban polluted environments. Nonetheless the first half of the observation period was marked by intense but short pollution events (NR PM1 concentrations higher than 15 µg m-3), sea breeze phenomena and Saharan desert dust outbreaks (PM10 up to 900 µg m-3). During the second half of the campaign, the sampling site was mainly under the influence of marine air masses. The air masses on days under continental and sea breeze influences were dominated by organics (36-40 %), whereas sulfate particles were predominant (40 %) for days under oceanic influence. Overall, measurements showed that about three-quarters of the total PM1 were explained by NR PM1, BC (black carbon) and Fe (a proxy for dust) concentrations, leaving approximately one-quarter for other refractory species. A mean value of 4.6 % for the Fe / PM1 ratio was obtained. Source apportionment of the organic fraction, using positive matrix factorization (PMF), highlighted the impact of local combustion sources, such as traffic and residential activities, which contribute on average to 52 % of the total organic fraction. A new organic aerosol (OA) source

  8. Measuring the fractal dimension of the seismic source through the high-frequency fall-off of source spectra

    International Nuclear Information System (INIS)

    Wu, Z.L.; Chen, Y.T.; Kim, S.G.

    1995-09-01

    Using the Wigner-distribution estimation, the high-frequency fall-off of source spectra was estimated. The technique was applied to the analysis of the source spectra of the July 22, 1994, Vladivostok M6.4 deep-focus earthquake and that of the July 22, 1994, Northern Japan Sea M5.7 deep-focus earthquake. It is shown that the high-frequency fall-off of the source spectra of these two earthquakes may be characterized by two parts. Between the first corner frequency f 1 and the second corner frequency f 2 , the high-frequency fall-off of the source spectra can be represented by f 5.0 : above f 2 , the high-frequency fall-off can be represented by f 1.4 . In the perspective of the fractal geometry of earthquake source, it seems that the deep-focus earthquakes under consideration may be characterized as being composed of some 'sub events'. On the other hand, each sub event has its complex structure. (author). 12 refs, 3 figs, 1 tab

  9. A measurement-based X-ray source model characterization for CT dosimetry computations.

    Science.gov (United States)

    Sommerville, Mitchell; Poirier, Yannick; Tambasco, Mauro

    2015-11-08

    The purpose of this study was to show that the nominal peak tube voltage potential (kVp) and measured half-value layer (HVL) can be used to generate energy spectra and fluence profiles for characterizing a computed tomography (CT) X-ray source, and to validate the source model and an in-house kV X-ray dose computation algorithm (kVDoseCalc) for computing machine- and patient-specific CT dose. Spatial variation of the X-ray source spectra of a Philips Brilliance and a GE Optima Big Bore CT scanner were found by measuring the HVL along the direction of the internal bow-tie filter axes. Third-party software, Spektr, and the nominal kVp settings were used to generate the energy spectra. Beam fluence was calculated by dividing the integral product of the spectra and the in-air NIST mass-energy attenuation coefficients by in-air dose measurements along the filter axis. The authors found the optimal number of photons to seed in kVDoseCalc to achieve dose convergence. The Philips Brilliance beams were modeled for 90, 120, and 140 kVp tube settings. The GE Optima beams were modeled for 80, 100, 120, and 140 kVp tube settings. Relative doses measured using a Capintec Farmer-type ionization chamber (0.65 cc) placed in a cylindrical polymethyl methacrylate (PMMA) phantom and irradiated by the Philips Brilliance, were compared to those computed with kVDoseCalc. Relative doses in an anthropomorphic thorax phantom (E2E SBRT Phantom) irradiated by the GE Optima were measured using a (0.015 cc) PTW Freiburg ionization chamber and compared to computations from kVDoseCalc. The number of photons required to reduce the average statistical uncertainty in dose to measurement over all 12 PMMA phantom positions was found to be 1.44%, 1.47%, and 1.41% for 90, 120, and 140 kVp, respectively. The maximum percent difference between calculation and measurement for all energies, measurement positions, and phantoms was less than 3.50%. Thirty-five out of a total of 36 simulation conditions were

  10. Measures against illicit trafficking of nuclear material and radioactive sources in the Republic of Belarus

    International Nuclear Information System (INIS)

    Piotoukh, O.

    2001-01-01

    Full text: The Republic of Belarus strives to take an active part in international cooperation in the field of prevention and interception of illicit uses of nuclear material and radioactive sources through: multilateral international agreements and bilateral interagency treatments; information exchange within the IAEA Illicit Trafficking Database; participation in different international seminars, workshops, conferences including those under the IAEA auspices etc. Belarus is constantly improving regulatory, legal and technical aspects of activities aimed at: accounting, control and ensuring of physical protection of nuclear material and security of radioactive sources; exercising efficient control over their export and import; detecting cases of their illicit uses and illegal cross-border movements and informing of such cases through the IAEA Illicit Trafficking Database; developing and providing training opportunities for personnel. Through Resolution 'On Measures for Physical Protection of Nuclear Materials' issued by the Council of Ministers in 1993, Committee for Supervision of Industrial and Nuclear Safety (PROMATOMNADZOR) was appointed as the authority responsible for ensuring physical protection of nuclear materials and facilities. Through Resolution 'On Measures for Fulfillment of Provisions of the Non-Proliferation Treaty' issued by the Council of Ministers in 1993, Promatomnadzor was designated as the national competent authority responsible for the establishment and maintenance of the State System of Accounting and Control of nuclear material. The system accounts all the nuclear material meeting the criteria defined in the Safeguards Agreement with the IAEA. The system includes two levels: i.e. on-site accounting and control and state accounting and control exercised by Promatomnadzor. Apart from reporting to the Agency, the system also provides for national tasks being accomplished: control over uses of nuclear material, its physical protection, access

  11. Airborne remote sensing and in situ measurements of atmospheric CO2 to quantify point source emissions

    Science.gov (United States)

    Krings, Thomas; Neininger, Bruno; Gerilowski, Konstantin; Krautwurst, Sven; Buchwitz, Michael; Burrows, John P.; Lindemann, Carsten; Ruhtz, Thomas; Schüttemeyer, Dirk; Bovensmann, Heinrich

    2018-02-01

    Reliable techniques to infer greenhouse gas emission rates from localised sources require accurate measurement and inversion approaches. In this study airborne remote sensing observations of CO2 by the MAMAP instrument and airborne in situ measurements are used to infer emission estimates of carbon dioxide released from a cluster of coal-fired power plants. The study area is complex due to sources being located in close proximity and overlapping associated carbon dioxide plumes. For the analysis of in situ data, a mass balance approach is described and applied, whereas for the remote sensing observations an inverse Gaussian plume model is used in addition to a mass balance technique. A comparison between methods shows that results for all methods agree within 10 % or better with uncertainties of 10 to 30 % for cases in which in situ measurements were made for the complete vertical plume extent. The computed emissions for individual power plants are in agreement with results derived from emission factors and energy production data for the time of the overflight.

  12. Industrial point source CO2 emission strength estimation with aircraft measurements and dispersion modelling.

    Science.gov (United States)

    Carotenuto, Federico; Gualtieri, Giovanni; Miglietta, Franco; Riccio, Angelo; Toscano, Piero; Wohlfahrt, Georg; Gioli, Beniamino

    2018-02-22

    CO 2 remains the greenhouse gas that contributes most to anthropogenic global warming, and the evaluation of its emissions is of major interest to both research and regulatory purposes. Emission inventories generally provide quite reliable estimates of CO 2 emissions. However, because of intrinsic uncertainties associated with these estimates, it is of great importance to validate emission inventories against independent estimates. This paper describes an integrated approach combining aircraft measurements and a puff dispersion modelling framework by considering a CO 2 industrial point source, located in Biganos, France. CO 2 density measurements were obtained by applying the mass balance method, while CO 2 emission estimates were derived by implementing the CALMET/CALPUFF model chain. For the latter, three meteorological initializations were used: (i) WRF-modelled outputs initialized by ECMWF reanalyses; (ii) WRF-modelled outputs initialized by CFSR reanalyses and (iii) local in situ observations. Governmental inventorial data were used as reference for all applications. The strengths and weaknesses of the different approaches and how they affect emission estimation uncertainty were investigated. The mass balance based on aircraft measurements was quite succesful in capturing the point source emission strength (at worst with a 16% bias), while the accuracy of the dispersion modelling, markedly when using ECMWF initialization through the WRF model, was only slightly lower (estimation with an 18% bias). The analysis will help in highlighting some methodological best practices that can be used as guidelines for future experiments.

  13. Biosignal PI, an Affordable Open-Source ECG and Respiration Measurement System

    Directory of Open Access Journals (Sweden)

    Farhad Abtahi

    2014-12-01

    Full Text Available Bioimedical pilot projects e.g., telemedicine, homecare, animal and human trials usually involve several physiological measurements. Technical development of these projects is time consuming and in particular costly. A versatile but affordable biosignal measurement platform can help to reduce time and risk while keeping the focus on the important goal and making an efficient use of resources. In this work, an affordable and open source platform for development of physiological signals is proposed. As a first step an 8–12 leads electrocardiogram (ECG and respiration monitoring system is developed. Chips based on iCoupler technology have been used to achieve electrical isolation as required by IEC 60601 for patient safety. The result shows the potential of this platform as a base for prototyping compact, affordable, and medically safe measurement systems. Further work involves both hardware and software development to develop modules. These modules may require development of front-ends for other biosignals or just collect data wirelessly from different devices e.g., blood pressure, weight, bioimpedance spectrum, blood glucose, e.g., through Bluetooth. All design and development documents, files and source codes will be available for non-commercial use through project website, BiosignalPI.org.

  14. Crowd-sourcing as an analytical method: Metrology of smartphone measurements in heritage science.

    Science.gov (United States)

    Brigham, Rosie; Grau-Bove, Josep; Rudnicka, Anna; Cassar, May; Strlic, Matija

    2018-04-12

    This research assesses the precision, repeatability and accuracy of crowd-sourced scientific measurements, and whether their quality is sufficient to provide usable results. Measurements of colour and area were chosen because of the possibility of producing them with smartphone cameras. The quality of measurements was estimated experimentally by comparing data contributed by anonymous participants in heritage sites with reference measurements of known accuracy and precision. Participants performed the measurements by taking photographs with their smartphones, from which colour and dimensional data could be extracted. The results indicate that smartphone measurements provided by citizen-scientists can be used to measure changes of colour, but that the performance is strongly dependent on the measured colour coordinate and ranges from a minimum detectable colour change or difference between colours of ΔE 3.1 to ΔE 17.2. The same method is able to measure areas when the difference in colour with the neighbouring areas is higher than ΔE 10. These results render the method useful in some heritage science contexts, but higher precision would be desirable: the human eye can detect differences as small as ΔE 2, and a light-fast pigment fades approximately ΔE 8 in its lifetime. There is scope for further research in the automatization of the post-processing of user contributions and the effect of contextual factors (such as detail in the instructions) in the quality of the raw data. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Situational awareness of hazards: Validation of multi-source radiation measurements

    Science.gov (United States)

    Hultquist, C.; Cervone, G.

    2016-12-01

    Citizen-led movements producing scientific hazard data during disasters are increasingly common. After the Japanese earthquake-triggered tsunami in 2011, and the resulting radioactive releases at the damaged Fukushima Daiichi nuclear power plants, citizens monitored on-ground levels of radiation with innovative mobile devices built from off-the-shelf components. To date, the citizen-led SAFECAST project has recorded 50 million radiation measurements worldwide, with the majority of these measurements from Japan. The analysis of data which are multi-dimensional, not vetted, and provided from multiple devices presents big data challenges due to their volume, velocity, variety, and veracity. While the SAFECAST project produced massive open-source radiation measurements at specific coordinates and times, the reliability and validity of the overall data have not yet been assessed. The nuclear disaster provides a case for assessing the SAFECAST data with official aerial remote sensing radiation data jointly collected by the governments of the United States and Japan. A spatial and statistical assessment of SAFECAST requires several preprocessing steps. First, SAFECAST ionized radiation sensors collected data using different units of measure than the government data, and they had to be converted. Secondly, the normally occurring radiation and decay rates of Cesium from deposition surveys were used to properly compare measurements in space and time. Finally, the GPS located points were selected within overlapping extents at multiple spatial resolutions. Quantitative measures were used to assess the similarity and differences in the observed measurements. Radiation measurements from the same geographic extents show similar spatial variations and statistically significant correlations. The results suggest that actionable scientific data for disasters and emergencies can be inferred from non-traditional and not vetted data generated through citizen science projects. This

  16. Measurement of greenhouse gases (GHGs) and source apportionment in Bakersfield, CA during CALNEX 2010

    Science.gov (United States)

    Guha, A.; Gentner, D. R.; Goldstein, A.; Provencal, R. A.; Gardner, A.; Calnex Bakersfield Science Team

    2010-12-01

    The California Global Warming Solutions Act 2006 creates a need to validate and improve the GHG inventory of the State, which has been largely based on activity and emission factor based estimates. As part of CALNEX 2010, we conducted measurements at the Bakersfield supersite of CO2, CH4, and N2O using fast response laser analyzers (LGR Inc.) to document the ambient mixing ratios of GHGs and analyze their major sources in the region, with an emphasis on understanding emissions of methane (CH4) and nitrous oxide (N2O). The site was located downwind of the urban center during the day and usually experienced a reversal of wind direction at night. Bakersfield is an urban area with heavy industrialization including petroleum refineries, oilfields, manufacturing, and cogeneration plants, all of which can be sources of the abovementioned GHGs. The site was close to a highway and potentially subject to vehicular CH4 and N2O emissions. Hence, CO and a broad variety of VOCs, which can serve as tracers (particularly for vehicle emissions), were included in the measurements to help with source apportionment. In addition to typical urban and industrial sources, Kern County is a rich agricultural region and includes a large number of cattle feedlots, dairies, settling ponds and landfills which are assumed to be some of the largest anthropogenic sources of methane in the State. Additionally, the agricultural industry uses significant amounts of fertilizers, which can lead to production of N2O from the soils along with emissions from controlled biomass burning of agricultural waste. The three GHGs studied show a strong diurnal pattern with concentrations building up in the night-time as the planetary boundary layer (PBL) becomes smaller and reversal in wind direction causes the site to become downwind of some GHG sources like landfills and feedlots. The mean background concentrations at the site (CNO2= 323 ppb; CCO2 = 390 ppm) during the day were consistent with those from the

  17. A Radon Chamber without Radium Source for Detector Calibration and Radon Measurements

    International Nuclear Information System (INIS)

    Al-Azmi, D.; Karunakara, N.

    2008-01-01

    A radon chamber of volume 216 liters was designed and constructed for calibration of radon detectors and radon test measurements. The main feature of this chamber is that the active 226 Ra source, to generate the 222 Rn inside the chamber volume, is not required. Instead, 222 Rn from soil gas is utilized for this purpose. The supply of radon comes from the soil gas. Soil gas is drawn from the soil to fill the chamber with high radon concentration levels (∼ 80 kBq/m3). Desired radon concentration levels can be obtained by drawing the soil gas for different time durations and/or flow rate (author)

  18. RF radiation measurement for the Advanced Photon Source (AS) personnel safety system

    International Nuclear Information System (INIS)

    Song, J.J.; Kim, J.; Otocki, R.; Zhou, J.

    1995-01-01

    The Advanced Photon Source (APS) booster and storage ring RF system consists of five 1-MW klystrons, four 5-cell cavities, and sixteen single-cell cavities. The RF power is distributed through many hundreds of feet of WR2300 waveguide with H-hybrids and circulators. In order to protect personnel from the danger of RF radiation due to loose flanges or other openings in the waveguide system, three detector systems were implemented: an RF radiation detector, a waveguide pressure switch, and a Radiax aperture detector (RAD). This paper describes RF radiation measurements on the WR 2300 waveguide system

  19. Simple emittance measurement of H- beams from a large plasma source

    International Nuclear Information System (INIS)

    Guharay, S.K.; Tsumori, K.; Hamabe, M.; Takeiri, Y.; Kaneko, O.; Kuroda, T.

    1996-03-01

    An emittance meter is developed using pepper-pot method. Kapton foils are used to detect intensity distributions of small beamlets at the 'image' plane of the pepper-pot. Emittance of H - beams from a large plasma source for the neutral beam injector of the Large Helical Device (LHD) has been measured. The normalized emittance (95%) of a 6 mA H - beam with emission current density of about 10 mA/cm 2 is ∼0.59 mm mrad. The present system is very simple, and it eliminates many complexities of the existing schemes. (author)

  20. POLICIES AND MEASURES FOR RENEWABLE ENERGY SOURCES AND ACHIEVEMENT OF TARGETS BY 2020 IN CROATIA

    Directory of Open Access Journals (Sweden)

    Igor Raguzin

    2010-01-01

    Full Text Available This paper is considering set up a longer-term perspective and plan of actions for the development of renewable energy infrastructure in Croatia in accordance with the new Croatian Energy Sector Development Strategy. Overall target till the year 2020 has been calculated in accordance with effort sharing methodology used for Directive 2009/28/EC. The paper presents some main existing policies and measures for achieving this ambitious target, including feed-in tariffs, guarantees of origin, and greenhouse gas emissions taxation. It is addressed the necessity for creating enabling environment for promotion of renewable energy sources and gradually remove barriers for its stronger penetration on the energy market.

  1. PRISMA - a spectrometer for the measurement of coherent excitations on a pulsed spallation neutron source

    International Nuclear Information System (INIS)

    Andreani, C.; Cilloco, F.; Petrillo, C.; Sacchetti, F.; Windsor, C.G.

    1986-04-01

    The measurement of nuclear and magnetic excitation spectra from single crystal samples remains central to condensed matter physics. The requirements in terms of the range and resolution of the scattering vector Q and energy transfer h/2πω are reviewed and typical experiments with a well defined cross-section are chosen. The performance and limitations of existing instruments are reviewed. A design for a new spectrometer, PRISMA, to be installed on the UK spallation neutron source, ISIS, is presented. Its performance for chosen experiments is given in terms of the Q and h/2πω range covered in a single scan, the resolution and the count rate. (author)

  2. Phased Array Noise Source Localization Measurements Made on a Williams International FJ44 Engine

    Science.gov (United States)

    Podboy, Gary G.; Horvath, Csaba

    2010-01-01

    A 48-microphone planar phased array system was used to acquire noise source localization data on a full-scale Williams International FJ44 turbofan engine. Data were acquired with the array at three different locations relative to the engine, two on the side and one in front of the engine. At the two side locations the planar microphone array was parallel to the engine centerline; at the front location the array was perpendicular to the engine centerline. At each of the three locations, data were acquired at eleven different engine operating conditions ranging from engine idle to maximum (take off) speed. Data obtained with the array off to the side of the engine were spatially filtered to separate the inlet and nozzle noise. Tones occurring in the inlet and nozzle spectra were traced to the low and high speed spools within the engine. The phased array data indicate that the Inflow Control Device (ICD) used during this test was not acoustically transparent; instead, some of the noise emanating from the inlet reflected off of the inlet lip of the ICD. This reflection is a source of error for far field noise measurements made during the test. The data also indicate that a total temperature rake in the inlet of the engine is a source of fan noise.

  3. WormGender - Open-Source Software for Automatic Caenorhabditis elegans Sex Ratio Measurement.

    Directory of Open Access Journals (Sweden)

    Marta K Labocha

    Full Text Available Fast and quantitative analysis of animal phenotypes is one of the major challenges of current biology. Here we report the WormGender open-source software, which is designed for accurate quantification of sex ratio in Caenorhabditis elegans. The software functions include, i automatic recognition and counting of adult hermaphrodites and males, ii a manual inspection feature that enables manual correction of errors, and iii flexibility to use new training images to optimize the software for different imaging conditions. We evaluated the performance of our software by comparing manual and automated assessment of sex ratio. Our data showed that the WormGender software provided overall accurate sex ratio measurements. We further demonstrated the usage of WormGender by quantifying the high incidence of male (him phenotype in 27 mutant strains. Mutants of nine genes (brc-1, C30G12.6, cep-1, coh-3, him-3, him-5, him-8, skr-1, unc-86 showed significant him phenotype. The WormGender is written in Java and can be installed and run on both Windows and Mac platforms. The source code is freely available together with a user manual and sample data at http://www.QuantWorm.org/. The source code and sample data are also available at http://dx.doi.org/10.6084/m9.figshare.1541248.

  4. Measurement error in mobile source air pollution exposure estimates due to residential mobility during pregnancy.

    Science.gov (United States)

    Pennington, Audrey Flak; Strickland, Matthew J; Klein, Mitchel; Zhai, Xinxin; Russell, Armistead G; Hansen, Craig; Darrow, Lyndsey A

    2017-09-01

    Prenatal air pollution exposure is frequently estimated using maternal residential location at the time of delivery as a proxy for residence during pregnancy. We describe residential mobility during pregnancy among 19,951 children from the Kaiser Air Pollution and Pediatric Asthma Study, quantify measurement error in spatially resolved estimates of prenatal exposure to mobile source fine particulate matter (PM 2.5 ) due to ignoring this mobility, and simulate the impact of this error on estimates of epidemiologic associations. Two exposure estimates were compared, one calculated using complete residential histories during pregnancy (weighted average based on time spent at each address) and the second calculated using only residence at birth. Estimates were computed using annual averages of primary PM 2.5 from traffic emissions modeled using a Research LINE-source dispersion model for near-surface releases (RLINE) at 250 m resolution. In this cohort, 18.6% of children were born to mothers who moved at least once during pregnancy. Mobile source PM 2.5 exposure estimates calculated using complete residential histories during pregnancy and only residence at birth were highly correlated (r S >0.9). Simulations indicated that ignoring residential mobility resulted in modest bias of epidemiologic associations toward the null, but varied by maternal characteristics and prenatal exposure windows of interest (ranging from -2% to -10% bias).

  5. Salmonellosis outbreaks in the United States due to fresh produce: sources and potential intervention measures.

    Science.gov (United States)

    Hanning, Irene B; Nutt, J D; Ricke, Steven C

    2009-01-01

    Foodborne Salmonella spp. is a leading cause of foodborne illness in the United States each year. Traditionally, most cases of salmonellosis were thought to originate from meat and poultry products. However, an increasing number of salmonellosis outbreaks are occurring as a result of contaminated produce. Several produce items specifically have been identified in outbreaks, and the ability of Salmonella to attach or internalize into vegetables and fruits may be factors that make these produce items more likely to be sources of Salmonella. In addition, environmental factors including contaminated water sources used to irrigate and wash produce crops have been implicated in a large number of outbreaks. Salmonella is carried by both domesticated and wild animals and can contaminate freshwater by direct or indirect contact. In some cases, direct contact of produce or seeds with contaminated manure or animal wastes can lead to contaminated crops. This review examines outbreaks of Salmonella due to contaminated produce, the potential sources of Salmonella, and possible control measures to prevent contamination of produce.

  6. Automated tune measurements in the Advanced Light Source storage ring using a LabVIEW application

    International Nuclear Information System (INIS)

    Hinkson, J.A.; Chin, M.; Kim, C.H.; Nishimura, H.

    1994-06-01

    Horizontal and vertical betatron tunes and the synchrotron tune are measured frequently during storage ring commissioning. The measurements are tedious and subject to human errors. Automating this kind of repetitive measurement is underway using LabVIEW for Windows, a software application supplied by National Instruments Corporation, that provides acquisition, graphing, and analysis of data as well as instrument control through the General Purpose Interface Bus (GPIB). We have added LabVIEW access to the Advanced Light Source (ALS) data base and control system. LabVIEW is a fast and efficient tool for accelerator commissioning and beam physics studies. Hardware used to perform tune measurements include a tracking generator (or a white noise generator), strip line electrodes for external ''citation of the beam, button monitors, and a spectrum analyzer. All three tunes are displayed simultaneously on the spectrum analyzer. Our program automatically identifies three tunes by applying and analyzing small variations and reports the results. This routine can be encapsulated in other applications, for instance, in a chromaticity measurement and correction program

  7. Experimental sources of variation in avian energetics: estimated basal metabolic rate decreases with successive measurements.

    Science.gov (United States)

    Jacobs, Paul J; McKechnie, Andrew E

    2014-01-01

    Basal metabolic rate (BMR) is one of the most widely used metabolic variables in endotherm ecological and evolutionary physiology. Surprisingly few studies have investigated how BMR is influenced by experimental and analytical variables over and above the standardized conditions required for minimum normothermic resting metabolism. We tested whether avian BMR is affected by habituation to the conditions experienced during laboratory gas exchange measurements by measuring BMR five times in succession in budgerigars (Melopsittacus undulatus) housed under constant temperature and photoperiod. Both the magnitude and the variability of BMR decreased significantly with repeated measurements, from 0.410 ± 0.092 W (n = 9) during the first measurement to 0.285 ± 0.042 W (n = 9) during the fifth measurement. Thus, estimated BMR decreased by ∼30% within individuals solely on account of the number of times they had previously experienced the experimental conditions. The most likely explanation for these results is an attenuation with repeated exposure of the acute stress response induced by birds being handled and placed in respirometry chambers. Our data suggest that habituation to experimental conditions is potentially an important determinant of observed BMR, and this source of variation needs to be taken into account in future studies of metabolic variation among individuals, populations, and species.

  8. Design of a high order Campbelling mode measurement system using open source hardware

    Energy Technology Data Exchange (ETDEWEB)

    Izarra, G. de [CEA, DEN,DER, Experimental Programs Laboratory, Cadarache F-13108 Saint-Paul-lez-Durance (France); Elter, Zs. [Chalmers University of Technology, Department of Physics, Division of Subatomic and Plasma Physics, SE-412 96 Göteborg (Sweden); CEA, DEN,DER, Instrumentation, Sensors and Dosimetry Laboratory, Cadarache F-13108 Saint-Paul-lez-Durance (France); Jammes, C. [CEA, DEN,DER, Instrumentation, Sensors and Dosimetry Laboratory, Cadarache F-13108 Saint-Paul-lez-Durance (France)

    2016-12-11

    This paper reviews a new real-time measurement instrument dedicated for online neutron monitoring with fission chambers in nuclear reactors. The instrument implements the higher order Campbelling methods and self-monitoring capabilities on an open source development board. The board includes an CPU/FPGA System on a Chip. The feasibility of the measurement instrument was tested both in laboratory with a signal generator and in the Minerve reactor. It is shown that the instrument provides reliable and robust count rate estimation over a wide reactor power range based on the third order statistics of the fission chamber signal. In addition, the system is able to identify whether the measured count rate change is due to the malfunction of the detector or due to the change in the neutron flux. The applied self-monitoring method is based on the spectral properties of the fission chamber signal. During the experimental verification, the considered malfunction was the change of the polarization voltage. - Highlights: • A new online High Order Campelling measurement system is proposed. • It includes a fission chamber failure detection system. • The complete architecture of the measurement system is given. • Test on reactor show its accuracy over a wide count rate range.

  9. Initial time-resolved particle beam profile measurements at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Yang, B.X.; Lumpkin, A.H.

    1995-01-01

    The commissioning of the 7-GeV Advanced Photon Source (APS) storage ring began in early 1995. Characterization of the stored particle beam properties involved time-resolved transverse and longitudinal profile measurements using optical synchrotron radiation (OSR) monitors. Early results include the observation of the beam on a single turn, measurements of the transverse beam sizes after damping using a 100 μs integration time (σ x ∼ 150 ± 25 μm, σ γ ∼ 65 ± 25 μm, depending on vertical coupling), and measurement of the bunch length (σ τ ∼ 25 to 55 ps, depending on the charge per bunch). The results are consistent with specifications and predictions based on the 8.2 nm-rad natural emittance, the calculated lattice parameters, and vertical coupling less than 10%. The novel, single-element focusing mirror for the photon transport line and the dual-sweep streak camera techniques which allow turn-by-turn measurements will also be presented. The latter measurements are believed to be the first of their kind on a storage ring in the USA

  10. Measurement of the energy and power radiated by a pulsed blackbody x-ray source

    International Nuclear Information System (INIS)

    Chandler, Gordon Andrew; McDaniel, Dillon Heirman; Jorgenson, Roy E.; Warne, Larry Kevin; Dropinski, Steven Clark; Hanson, Donald L.; Johnson, William Arthur; York, Mathew William; Lewis, D.F.; Korde, R.; Haslett, C.L.; Wall, D.L.; Ruggles, Laurence E.; Ramirez, L.E.; Stygar, William A.; Porter, John Larry Jr.; McKenney, John Lee; Bryce, Edwin Anthony; Cuneo, Michael Edward; Torres, Jose A.; Mills, Jerry Alan; Leeper, Ramon Joe; McGurn, John Stephen; Fehl, David Lee; Spielman, R. B.; Pyle, John H.; Mazarakis, Michael Gerrassimos; Ives III, Harry Crockett; Seamen, Johann F.; Simpson, Walter W.

    2006-01-01

    We have developed a diagnostic system that measures the spectrally integrated (i.e. the total) energy and power radiated by a pulsed blackbody x-ray source. The total-energy-and-power (TEP) diagnostic system is optimized for blackbody temperatures between 50 and 350 eV. The system can view apertured sources that radiate energies and powers as high as 2 MJ and 200 TW, respectively, and has been successfully tested at 0.84 MJ and 73 TW on the Z pulsed-power accelerator. The TEP system consists of two pinhole arrays, two silicon-diode detectors, and two thin-film nickel bolometers. Each of the two pinhole arrays is paired with a single silicon diode. Each array consists of a 38 x 38 square array of 10-(micro)m-diameter pinholes in a 50-(micro)m-thick tantalum plate. The arrays achromatically attenuate the x-ray flux by a factor of ∼1800. The use of such arrays for the attenuation of soft x rays was first proposed by Turner and co-workers [Rev. Sci. Instrum. 70, 656 (1999)RSINAK0034-674810.1063/1.1149385]. The attenuated flux from each array illuminates its associated diode; the diode's output current is recorded by a data-acquisition system with 0.6-ns time resolution. The arrays and diodes are located 19 and 24 m from the source, respectively. Because the diodes are designed to have an approximately flat spectral sensitivity, the output current from each diode is proportional to the x-ray power. The nickel bolometers are fielded at a slightly different angle from the array-diode combinations, and view (without pinhole attenuation) the same x-ray source. The bolometers measure the total x-ray energy radiated by the source and--on every shot--provide an in situ calibration of the array-diode combinations. Two array-diode pairs and two bolometers are fielded to reduce random uncertainties. An analytic model (which accounts for pinhole-diffraction effects) of the sensitivity of an array-diode combination is presented

  11. An update on measurements of helium-production reactions with a spallation neutron source

    International Nuclear Information System (INIS)

    Haight, R.C.; Bateman, F.B.; Chadwick, M.B.

    1995-01-01

    This report gives the status, updated since the last Research Coordination Meeting, of alpha-particle production cross sections, emission spectra and angular distributions which we are measuring at the spallation source of fast neutrons at the Los Alamos Meson Physics Facility (LAMPF). Detectors at angles of 30, 60, 90 and 135 degrees are used to identify alpha particles, measure their energy spectra, and indicate the time-of-flight, and hence the energy, of the neutrons inducing the reaction. The useful neutron energy ranges from less than 1 MeV to approximately 50 MeV for the present experimental setup. Targets under study at present include C, N, 0, 27 Al, Si, 51 V, 56 Fe, 59 CO, 58,60 Ni, 89 Y and 93 Nb. Data for 59 Co have been re-analyzed. The results illustrate the capabilities of the approach, agreement with literature values, and comparisons with nuclear reaction model calculations

  12. Measurement of spherical compound refractive X-ray lens at ANKA synchrotron radiation source

    International Nuclear Information System (INIS)

    Dudchik, Yu.I.; Simon, R.; Baumbach, T.

    2007-01-01

    Parameters of compound refractive X-ray lens were measured at ANKA synchrotron radiation source. The lens consists of 224 spherical concave epoxy microlenses formed inside glass capillary. The curvature radius of individual microlens is equal to 100 microns. Measured were: X-ray focal spot, lens focal length and gain in intensity. The energy of X-ray beam was equal to 12 keV and 14 keV. It is shown that when X-ray lens is used, the gain in intensity of the X-ray beam in some cases may exceed value of 100. Tested lens is suitable to focus X-rays into, at least, 2-microns in size spot. (authors)

  13. A heat source probe for measuring thermal conductivity in waste rock dumps

    International Nuclear Information System (INIS)

    Blackford, M.G.; Harries, J.R.

    1985-10-01

    The development and use of a heat source probe to measure the thermal conductivity of the material in a waste rock dump is described. The probe releases heat at a constant rate into the surrounding material and the resulting temperature rise is inversely related to the thermal conductivity. The probe was designed for use in holes in the dump which are lined with 50 mm i.d. polyethylene liners. The poor thermal contact between the probe and the liner and the unknown conductivity of the backfill material around the liner necessitated long heating and cooling times (>10 hours) to ensure that the thermal conductivity of the dump material was being measured. Temperature data acquired in the field were analysed by comparing them with temperatures calculated using a two-dimensional cylindrical model of the probe and surrounding material, and the heat transfer code HEATRAN

  14. White source gamma-ray production spectral measurement facilities in the USA

    International Nuclear Information System (INIS)

    Larson, D.C.; Dickens, J.K.; Nelson, R.O.; Wender, S.A.

    1991-01-01

    The two primary neutron sources for measuring gamma-ray production (GRP) cross sections for basic and applied work in the USA are the Oak Ridge Electron Linear Accelerator (ORELA) located at the Oak Ridge National Laboratory (ORNL) and the Weapons Neutron Research (WNR) facility located at the Los Alamos National Laboratory (LANL). ORELA is based on a 180-MeV electron linear accelerator, while the WNR facility uses the Los Alamos Meson Physics Facility 800 MeV proton beam to produce neutrons. The facilities collectively cover the neutron-energy range from thermal to over 700 MeV. The paper describes the present capabilities for GRP measurements at each facility. 18 refs

  15. Automatic device for measuring β-emitting sources: P.A.P.A. β-meters

    International Nuclear Information System (INIS)

    Colomer, J.; Valentin, M.

    1969-01-01

    The apparatus described is designed for measuring β-emitting elements by the absorption method; it is suitable for carrying out a large number of routine analyses. A mechanical device pushes an aluminium absorption set automatically between the source and the detector; the movement is programmed for cutting on and off by a transistorized electronic unit, with printing out and punching of the results on tape; then this can be mathematically processed by a computer (tracing of absorption spectra, extrapolation and calculation of the activity). The detector is either a β-probe or a proportional counter with a specially designed loop. For routine measurements, the accuracy obtained, with all corrections made, is from 5 to 8 per cent; the reproducibility is about 2 per cent. (authors) [fr

  16. Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Torrisi, Giuseppe [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); University Mediterranea of Reggio Calabria, Reggio Calabria (Italy); Mascali, David; Neri, Lorenzo; Leonardi, Ornella; Celona, Luigi; Castro, Giuseppe; Agnello, Riccardo; Caruso, Antonio; Passarello, Santi; Longhitano, Alberto; Gammino, Santo [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); Sorbello, Gino [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); University of Catania, Catania, Italy and INFN-LNS, Catania (Italy); Isernia, Tommaso [University Mediterranea of Reggio Calabria, Reggio Calabria (Italy)

    2016-02-15

    The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

  17. In vivo crystalline lens measurements with novel swept-source optical coherent tomography: an investigation on variability of measurement

    Science.gov (United States)

    Shoji, Takuhei; Kato, Naoko; Ishikawa, Sho; Ibuki, Hisashi; Yamada, Norihiro; Kimura, Itaru; Shinoda, Kei

    2017-01-01

    Objective To evaluate the reproducibility of in vivo crystalline lens measurements obtained by novel commercially available swept-source (SS) optical coherence tomography (OCT) specifically designed for anterior segment imaging. Methods and analysis One eye from each of 30 healthy subjects was randomly selected using the CASIA2 (Tomey, Nagoya, Japan) in two separate visits within a week. Each eye was imaged twice. After image scanning, the anterior and posterior lens curvatures and lens thickness were calculated automatically by the CASIA2 built-in program at 0 dioptre (D) (static), −1 D, −3 D and −5 D accommodative stress. The intraobserver and intervisit reproducibility coefficient (RC) and intraclass correlation coefficient (ICC) were calculated. Results The intraobserver and intervisit RCs ranged from 0.824 to 1.254 mm and 0.789 to 0.911 mm for anterior lens curvature, from 0.276 to 0.299 mm and 0.221 to 0.270 mm for posterior lens curvature and from 0.065 to 0.094 mm and 0.054 to 0.132 mm for lens thickness, respectively. The intraobserver and intervisit ICCs ranged from 0.831 to 0.865 and 0.828 to 0.914 for anterior lens curvature, from 0.832 to 0.898 and 0.840 to 0.933 for posterior lens curvature and from 0.980 to 0.992 and 0.942 to 0.995 for lens thickness. High ICC values were observed for each measurement regardless of accommodative stress. RCs in younger subjects tended to be larger than those in older subjects. Conclusions This novel anterior segment SS-OCT instrument produced reliable in vivo crystalline lens measurement with good repeatability and reproducibility regardless of accommodation stress. PMID:29354706

  18. On the Measurement of the Velocity of Light Emitted by an Ultrarelativistic Source

    Science.gov (United States)

    Kupryaev, N. V.

    2015-01-01

    By analytical calculations it has been shown that in papers on the measurement of the velocity of light published in 2011 in the journals Uspekhi Fizicheskikh Nauk [Physics-Uspekhi] and Pis'ma v ZhETF [JRTP Letters], in actual fact the velocity of a light pulse from a relativistic clot of electrons was not measured. All that was done was to compare the velocity of light emitted by an ultrarelativistic source with the velocity of light from a fixed source, i.e., both in the first and second variants (one independent quantity was compared with another), in essence, it was simply postulated. In the first variant a glass plate was used as the fixed light source, and in the second variants, a synchrotron pulse was used as the reference signal. The velocity of light was calculated using a calculated time based on the postulate of the special theory of relativity (STR) on the invariance of the velocity of light. This, of course, contradicts the Newton-Ritz hypothesis on ballistic addition of velocities, but at the present time this idea is not taken seriously. Practically none of the serious contemporary critics of STR, apart, of course, from amateurs, holds this point of view. The result cannot be considered as a direct experimental confirmation of the second postulate of Einstein's special theory of relativity, i.e., its main part, which speaks of the constancy of the velocity of light in all inertial reference frames, but only of that part which speaks of the independence of the velocity of light on motion of the source. Moreover, this same result stands as equal proof of the so-called theory of the luminiferous ether, which held sway up to the creation of the special theory of relativity and which has now been revived, i.e., it does not distinguish between these two theories. It is fundamentally impossible in principle to measure the velocity of light by the proposed method, it is only possible to postulate it.

  19. Challenges and Opportunities for Using Crowd-Sourced Air Pollution Measurements for Education and Outreach

    Science.gov (United States)

    Stanier, C. O.; Dong, C.; Janechek, N. J.; Bryngelson, N.; Schultz, P.; Heimbinder, M.

    2017-12-01

    As part of the CLE4R air quality education project, the University of Iowa has been working with AirBeam low-cost consumer-grade fine particulate matter (PM2.5) sensors in educational and outreach settings, both in K-12 environments and in informal settings such as science days and technology fairs. Users are attracted to the AirBeam device, in part, because of the easy creation of crowd-sourced maps of air pollution. With over 1000 AirBeam devices in use, extensive measurements are now available at aircasting.org. The AirBeam sensor is a portable, low-cost sensor which measures light scattering due to aerosols as a single bin converting the detected signal to a particle count and uses a calibration fit to estimate particle mass. The AirBeam is able to detect particle sizes of 0.5 - 2.5 µm, concentrations up to 400 µg m-3, and with a time resolution of 1 s. A corresponding Android device is used to visualize, record, and upload measured data to a community website (aircasting.org) that maps the spatial and temporal resolved data. The non-profit vendor's website constructs crowdsourced maps of air quality, environmental, and meteorological variables. As of April 1st, 2017, through the CLE4R project, 109 people had used the AirBeam sensors for educational purposes, for a total of 271 person hours. In the poster, we will explain the outreach that was done, and share best practices for education and outreach using consumer-grade PM sensors. Strengths and needed improvements to the technology for these outreach, education, and classroom uses will also be detailed. Sources of particles that can be artificially generated for educational use, including authentic smoke, spray smoke, and various dust sources will be enumerated. For use in K-12 classrooms, requirements for robust startup, operation, and ease-of-use are high. Mapping of concentrations is a desirable attribute but adds additional sources of failure to the hardware-software system used for education/outreach.

  20. Measurements and modeling of intra-ELM tungsten sourcing and transport in DIII-D

    Science.gov (United States)

    Abrams, T.; Leonard, A. W.; Thomas, D. M.; McLean, A. G.; Makowski, M. A.; Wang, H. Q.; Unterberg, E. A.; Briesemeister, A. R.; Rudakov, D. L.; Bykov, I.; Donovan, D.

    2017-10-01

    Intra-ELM tungsten erosion profiles in the DIII-D divertor, acquired via W I spectroscopy with high temporal and spatial resolution, are consistent with SDTrim.SP sputtering modeling using measured ion saturation currents and impact energies during ELMs as input and an ad-hoc 2% C2+ impurity flux. The W sputtering profile peaks close to the OSP both during and between ELMs in the favorable BT direction. In reverse BT the W source peaks close to the OSP between ELMs but strongly broadens and shifts outboard during ELMs, heuristically consistent with radially outward ion transport via ExB drifts. Ion impact energies during ELMs (inferred taking the ratio of divertor heat flux to the ion saturation current) are found to be approximately equal to Te,ped, lower than the 4*Te,ped value predicted by the Fundamenski/Moulton free streaming model. These impact energies imply both D main ions and C impurities contribute strongly to W sputtering during ELMs on DIII-D. This work represents progress towards a predictive model to link upstream conditions (i.e., pedestal height) and SOL impurity levels to the ELM-induced W impurity source at both the strike-point and far-target regions in the ITER divertor. Correlations between ELM size/frequency and SOL W fluxes measured via a midplane deposition probe will also be presented. Work supported by US DOE under DE-FC02-04ER54698.

  1. MicroRNA Expression Varies according to Glucose Tolerance, Measurement Platform, and Biological Source

    Directory of Open Access Journals (Sweden)

    S. Dias

    2017-01-01

    Full Text Available Dysregulated microRNA (miRNA expression is observed during type 2 diabetes (T2D, although the consistency of miRNA expression across measurement platform and biological source is uncertain. Here we report miRNA profiling in the whole blood and serum of South African women with different levels of glucose tolerance, using next generation sequencing (NGS and quantitative real time PCR (qRT-PCR. Whole blood-derived miRNAs from women with newly diagnosed T2D (n=4, impaired glucose tolerance (IGT (n=4, and normal glucose tolerance (NGT (n=4 were subjected to NGS, whereafter transcript levels of selected miRNAs were quantified in the whole blood and serum of these women using qRT-PCR. Of the five significantly differentially expressed miRNAs identified by NGS, only the directional increase of miR-27b in women with IGT compared to NGT was confirmed in whole blood and serum, using qRT-PCR. Functional enrichment of miR-27b gene targets identified biological pathways associated with glucose transport and insulin regulation. In conclusion, this study showed poor correlation in miRNA expression profiled using NGS and qRT-PCR and in whole blood and serum. The consistent increased expression of miR-27b in women with IGT compared to NGT across measurement platform and biological source holds potential as a biomarker for risk stratification in our population.

  2. Eddy covariance methane flux measurements over a grazed pasture: effect of cows as moving point sources

    Science.gov (United States)

    Felber, R.; Münger, A.; Neftel, A.; Ammann, C.

    2015-06-01

    Methane (CH4) from ruminants contributes one-third of global agricultural greenhouse gas emissions. Eddy covariance (EC) technique has been extensively used at various flux sites to investigate carbon dioxide exchange of ecosystems. Since the development of fast CH4 analyzers, the instrumentation at many flux sites has been amended for these gases. However, the application of EC over pastures is challenging due to the spatially and temporally uneven distribution of CH4 point sources induced by the grazing animals. We applied EC measurements during one grazing season over a pasture with 20 dairy cows (mean milk yield: 22.7 kg d-1) managed in a rotational grazing system. Individual cow positions were recorded by GPS trackers to attribute fluxes to animal emissions using a footprint model. Methane fluxes with cows in the footprint were up to 2 orders of magnitude higher than ecosystem fluxes without cows. Mean cow emissions of 423 ± 24 g CH4 head-1 d-1 (best estimate from this study) correspond well to animal respiration chamber measurements reported in the literature. However, a systematic effect of the distance between source and EC tower on cow emissions was found, which is attributed to the analytical footprint model used. We show that the EC method allows one to determine CH4 emissions of cows on a pasture if the data evaluation is adjusted for this purpose and if some cow distribution information is available.

  3. Measurement of Neutron Energy Spectrum Emitted by Cf-252 Source Using Time-of-Flight Method

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheol Ho; Son, Jaebum; Kim, Tae Hoon; Lee, Sangmin; Kim, Yong-Kyun [Hanyang University, Seoul (Korea, Republic of)

    2016-10-15

    The techniques proposed to detect the neutrons usually require the detection of a secondary recoiling nucleus in a scintillator (or other type of detector) to indicate the rare collision of a neutron with a nucleus. This is the same basic technique, in this case detection of a recoil proton that was used by Chadwick in the 1930 s to discover and identify the neutron and determine its mass. It is primary technique still used today for detection of fast neutron, which typically involves the use of a hydrogen based organic plastic or liquid scintillator coupled to a photo-multiplier tube. The light output from such scintillators is a function of the cross section and nuclear kinematics of the n + nucleus collision. With the exception of deuterated scintillators, the scintillator signal does not necessarily produce a distinct peak in the scintillator spectrum directly related to the incident neutron energy. Instead neutron time-of-flight (TOF) often must be utilized to determine the neutron energy, which requires generation of a prompt start signal from the nuclear source emitting the neutrons. This method takes advantage of the high number of prompt gamma rays. The Time-of-Flight method was used to measure neutron energy spectrum emitted by the Cf-252 neutron source. Plastic scintillator that has a superior discrimination ability of neutron and gamma-ray was used as a stop signal detector and liquid scintillator was used as a stat signal detector. In experiment, neutron and gamma-ray spectrum was firstly measured and discriminated using the TOF method. Secondly, neutron energy spectrum was obtained through spectrum analysis. Equation of neutron energy spectrum that was emitted by Cf-252 source using the Gaussian fitting was obtained.

  4. Measurements on low level plutonium sources using Rad Elec Electret Ion Chambers

    International Nuclear Information System (INIS)

    Levinskas, D.; Teagarden, J.; Wilkes, E.

    1998-01-01

    This is a technique for measuring gross alpha particle emission from interior contaminated surfaces. The technique utilizes electret ionization chambers (EICs), which consist of a charged Teflon plate (the electret) and an electrically-conductive plastic chamber of 145 ml volume. To measure very low levels of alpha contamination, the EIC is left in place on the surface to be measured for about 48 hours. The change in the surface charge of the electret is a measure of the ionization during the measurement period. The rate of change of the charge is converted into an activity using an appropriate calibration factor. This system has the ability to make accurate gross alpha contamination measurements while being subject to a high airborne radon concentration, such as might occur in certain buildings or during an atmospheric inversion. Previous studies of the effectiveness of these EIC's focused on levels of alpha contamination much higher than is allowed for unrestricted release of material at the Rocky Flats Environmental Technology Site (RFETS). This study evaluated the performance of EIC's at levels from 100 disintegrations per minute (dpm) per 100 cm 2 to below 20 dpm per 100 cm 2 (all measurements are referenced to a 4π geometry). The EIC's were found to be within 5% accuracy, as compared to a gas flow proportional counter calibrated with a NIST-traceable source. Test results indicate that the EIC, left in place for 48 hours, can detect alpha contamination as low as 6.4 ± 3.0 dpm/100 cm 2 to a 95% confidence level

  5. A unified free-form representation applied to the shape optimization of the hohlraum with octahedral 6 laser entrance holes

    International Nuclear Information System (INIS)

    Jiang, Shaoen; Ding, Yongkun; Huang, Yunbao; Li, Haiyan; Jing, Longfei; Huang, Tianxuan

    2016-01-01

    The hohlraum is very crucial for indirect laser driven Inertial Confinement Fusion. Usually, its shape is designed as sphere, cylinder, or rugby with some kind of fixed functions, such as ellipse or parabola. Recently, a spherical hohlraum with octahedral 6 laser entrance holes (LEHs) has been presented with high flux symmetry [Lan et al., Phys. Plasmas 21, 010704 (2014); 21, 052704 (2014)]. However, there is only one shape parameter, i.e., the hohlraum to capsule radius ratio, being optimized. In this paper, we build the hohlraum with octahedral 6LEHs with a unified free-form representation, in which, by varying additional shape parameters: (1) available hohlraum shapes can be uniformly and accurately represented, (2) it can be used to understand why the spherical hohlraum has higher flux symmetry, (3) it allows us to obtain a feasible shape design field satisfying flux symmetry constraints, and (4) a synthetically optimized hohlraum can be obtained with a tradeoff of flux symmetry and other hohlraum performance. Finally, the hohlraum with octahedral 6LEHs is modeled, analyzed, and then optimized based on the unified free-form representation. The results show that a feasible shape design field with flux asymmetry no more than 1% can be obtained, and over the feasible design field, the spherical hohlraum is validated to have the highest flux symmetry, and a synthetically optimal hohlraum can be found with closing flux symmetry but larger volume between laser spots and centrally located capsule

  6. A unified free-form representation applied to the shape optimization of the hohlraum with octahedral 6 laser entrance holes

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Shaoen; Ding, Yongkun [Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang 621900 (China); Center for Applied Physics and Technology, Peking University, Beijing 100871 (China); Huang, Yunbao, E-mail: Huangyblhy@gmail.com, E-mail: scmyking-2008@163.com; Li, Haiyan [Key Laboratory of Computer Integrated Manufacturing System, Guangdong University of Technology, Guangzhou 510006 (China); Jing, Longfei, E-mail: Huangyblhy@gmail.com, E-mail: scmyking-2008@163.com; Huang, Tianxuan [Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang 621900 (China)

    2016-01-15

    The hohlraum is very crucial for indirect laser driven Inertial Confinement Fusion. Usually, its shape is designed as sphere, cylinder, or rugby with some kind of fixed functions, such as ellipse or parabola. Recently, a spherical hohlraum with octahedral 6 laser entrance holes (LEHs) has been presented with high flux symmetry [Lan et al., Phys. Plasmas 21, 010704 (2014); 21, 052704 (2014)]. However, there is only one shape parameter, i.e., the hohlraum to capsule radius ratio, being optimized. In this paper, we build the hohlraum with octahedral 6LEHs with a unified free-form representation, in which, by varying additional shape parameters: (1) available hohlraum shapes can be uniformly and accurately represented, (2) it can be used to understand why the spherical hohlraum has higher flux symmetry, (3) it allows us to obtain a feasible shape design field satisfying flux symmetry constraints, and (4) a synthetically optimized hohlraum can be obtained with a tradeoff of flux symmetry and other hohlraum performance. Finally, the hohlraum with octahedral 6LEHs is modeled, analyzed, and then optimized based on the unified free-form representation. The results show that a feasible shape design field with flux asymmetry no more than 1% can be obtained, and over the feasible design field, the spherical hohlraum is validated to have the highest flux symmetry, and a synthetically optimal hohlraum can be found with closing flux symmetry but larger volume between laser spots and centrally located capsule.

  7. Measurement and apportionment of radon source terms for modeling indoor environments

    International Nuclear Information System (INIS)

    Harley, N.H.

    1992-01-01

    During the present 2 1/2 year contract period, we have made significant Progress in modeling the source apportionment of indoor 222 Rn and in 222 Rn decay product dosimetry. Two additional areas were worked on which we believe are useful for the DOE Radon research Program. One involved an analysis of the research house data, grouping the hourly house 222 Rn measurements into 2 day, 7 day and 90 day intervals to simulate the response of passive monitors. Another area requiring some attention resulted in a publication of 3 years of our indoor/outdoor measurements in a high-rise apartment. Little interest has been evinced in apartment measurements yet 20% of the US population lives in multiple-family dwellings, not in contact with the ground. These data together with a summary of all other published data on apartments showed that apartments have only about 50% greater 222 Rn concentration than the measured outdoor 222 Rn. Apartment dwellers generally represent a low risk group regarding 222 Rn exposure. The following sections describe the main projects in some detail

  8. Fusion Neutronic Source deuterium endash tritium neutron spectrum measurements using natural diamond detectors

    International Nuclear Information System (INIS)

    Krasilnikov, A.V.; Kaneko, J.; Isobe, M.; Maekawa, F.; Nishitani, T.

    1997-01-01

    Two natural diamond detectors (NDDs) operating at room temperature were used for Fusion Neutronics Source (FNS) deuterium endash tritium (DT) neutron spectra measurements at different points around the tritium target and for different deuteron beam energies. Energy resolution of both NDDs were measured, with values 1.95% and 2.8%. Due to the higher energy resolution of one of the two NDDs studied it was possible to measure the shape of the DT neutron energy distribution and its broadening due to deuteron scattering inside the target. The influence of pulse pileup on the energy resolution of the combined system (NDD+electronics) at count rates up to 3.8x10 5 counts/s was investigated. A 3.58% energy resolution for the spectrometric system based on NDD and a 0.25 μs shaping time amplifier has been measured at a count rate of 5.7x10 5 counts/s. It is shown that special development of a fast pulse signal processor is necessary for NDD based spectrometry at count rates of approximately 10 6 counts/s. copyright 1997 American Institute of Physics

  9. Phase loop bandwidth measurements on the advanced photon source 352 MHz rf systems

    International Nuclear Information System (INIS)

    Horan, D.; Nassiri, A.; Schwartz, C.

    1997-01-01

    Phase loop bandwidth tests were performed on the Advanced Photon Source storage ring 352-MHz rf systems. These measurements were made using the HP3563A Control Systems Analyzer, with the rf systems running at 30 kilowatts into each of the storage ring cavities, without stored beam. An electronic phase shifter was used to inject approximately 14 degrees of stimulated phase shift into the low-level rf system, which produced measureable response voltage in the feedback loops without upsetting normal rf system operation. With the PID (proportional-integral-differential) amplifier settings at the values used during accelerator operation, the measurement data revealed that the 3-dB response for the cavity sum and klystron power-phase loops is approximately 7 kHz and 45 kHz, respectively, with the cavities the primary bandwidth-limiting factor in the cavity-sum loop. Data were taken at various PID settings until the loops became unstable. Crosstalk between the two phase loops was measured

  10. Resolution and drift measurements on the Advanced Photon Source beam position monitors

    International Nuclear Information System (INIS)

    Chung, Y.; Kahana, E.

    1994-01-01

    The resolution and long-term drift of the Advanced Photon Source (APS) beam position monitor (BPM) electronics were measured using the charged particle beams in the ESRF storage ring with various beam current and configurations (single bunch, 8 and 16 equally spaced bunches, and 1/3-fill). The energy of the stored electrons was 6 GeV. The integrated BPM electronics system as used for this work is capable of measuring the beam position on a turn-by-turn basis, which can be accumulated for N turns (N = 2 n , n = 1, 2, ... , 11). Estimation of the BPM resolution apart from the low-frequency beam motion was made by measuring the standard deviation in the measured beam position with different Ns. The analysis of the results indicates a BPM resolution of 18/√ N [μm] for the APS storage ring, which is equivalent to 0.07 μm/√Hz. For the miniature insertion device BPM with 2.8 times higher sensitivity, the resolution will be 0.02 μm/√Hz. The long-term drift of the BPM electronics independent of the actual beam motion was measured at 2 μm/hr, which settled after approximately 1.5 hours. This drift can be attributed mainly to the temperature effect. Comparison of the results with the laboratory measurements shows good agreement. Implication of the BPM resolution limit on the proposed global and local beam position feedback systems for the APS storage ring will also be discussed

  11. Resolution and drift measurements on the advanced photon source beam position monitor

    International Nuclear Information System (INIS)

    Chung, Y.; Kahana, E.

    1995-01-01

    The resolution and long-term drift of the Advanced Photon Source (APS) beam position monitor (BPM) electronics were measured using the charged particle beams in the ESRF storage ring with various beam current and configurations (single bunch, 8 and 16 equally spaced bunches, and 1/3-fill). The energy of the stored electrons was 6 GeV. The integrated BPM electronics system as used for this work is capable of measuring the beam position on a turn-by-turn basis, which can be accumulated for N turns (N=2 n , n=1,2,...,11) . Estimation of the BPM resolution apart from the low-frequency beam motion was made by measuring the standard deviation in the measured beam position with different Ns. The analysis of the results indicates a BPM resolution of 18/√N [μm] for the APS storage ring, which is equivalent to 0.07 μm/√Hz. For the miniature insertion device BPM with 2.8 times higher sensitivity, the resolution will be 0.02 μm/√Hz. The long-term drift of the BPM electronics independent of the actual beam motion was measured at 2 μm/hr, which settled after approximately 1.5 hours. This drift can be attributed mainly to the temperature effect. Comparison of the results with the laboratory measurements shows good agreement. Implication of the BPM resolution limit on the proposed global and local beam position feedback systems for the APS storage ring will also be discussed. copyright 1995 American Institute of Physics

  12. Meeting water needs for sustainable development: an overview of approaches, measures and data sources

    Science.gov (United States)

    Lissner, Tabea; Reusser, Dominik E.; Sullivan, Caroline A.; Kropp, Jürgen P.

    2013-04-01

    An essential part of a global transition towards sustainability is the Millennium Development Goals (MDG), providing a blueprint of goals to meet human needs. Water is an essential resource in itself, but also a vital factor of production for food, energy and other industrial products. Access to sufficient water has only recently been recognized as a human right. One central MDG is halving the population without access to safe drinking water and sanitation. To adequately assess the state of development and the potential for a transition towards sustainability, consistent and meaningful measures of water availability and adequate access are thus fundamental. Much work has been done to identify thresholds and definitions to measure water scarcity. This includes some work on defining basic water needs of different sectors. A range of data and approaches has been made available from a variety of sources, but all of these approaches differ in their underlying assumptions, the nature of the data used, and consequently in the final results. We review and compare approaches, methods and data sources on human water use and human water needs. This data review enables identifying levels of consumption in different countries and different sectors. Further comparison is made between actual water needs (based on human and ecological requirements), and recognised levels of water abstraction. The results of our review highlight the differences between different accounts of water use and needs, and reflect the importance of standardised approaches to data definitions and measurements, making studies more comparable across space and time. The comparison of different use and allocation patterns in countries enables levels of water use to be identified which allow for an adequate level of human wellbeing to be maintained within sustainable water abstraction limits. Recommendations are provided of how data can be defined more clearly to make comparisons of water use more meaningful and

  13. Inverse kinetics method with source term for subcriticality measurements during criticality approach in the IPEN/MB-01 research reactor

    International Nuclear Information System (INIS)

    Loureiro, Cesar Augusto Domingues; Santos, Adimir dos

    2009-01-01

    In reactor physics tests which are performed at the startup after refueling the commercial PWRs, it is important to monitor subcriticality continuously during criticality approach. Reactivity measurements by the inverse kinetics method are widely used during the operation of a nuclear reactor and it is possible to perform an online reactivity measurement based on the point reactor kinetics equations. This technique is successful applied at sufficiently high power level or to a core without an external neutron source where the neutron source term in point reactor kinetics equations may be neglected. For operation at low power levels, the contribution of the neutron source must be taken into account and this implies the knowledge of a quantity proportional to the source strength, and then it should be determined. Some experiments have been performed in the IPEN/MB-01 Research Reactor for the determination of the Source Term, using the Least Square Inverse Kinetics Method (LSIKM). A digital reactivity meter which neglects the source term is used to calculate the reactivity and then the source term can be determined by the LSIKM. After determining the source term, its value can be added to the algorithm and the reactivity can be determined again, considering the source term. The new digital reactivity meter can be used now to monitor reactivity during the criticality approach and the measured value for the reactivity is more precise than the meter which neglects the source term. (author)

  14. The measurement results of radioactive sources in Turkish hardcoal enterprise (TTK)

    International Nuclear Information System (INIS)

    Gonul, Bicher

    2006-01-01

    Full text: In Health Department of TTK there are 3 roentgen equipments. Because of these equipments reflecting X-ray, therefore they categorized as the group of producing radioactive source.Each equipment has the capacity of 100 MA. According to radiation safeyt regulations and codes of practice, the equipment is used under the licence certificate of number 99/4173. In 2000, due to change of responsible personnel in the department, when TTK applied for changing licence, the application was rejected because responsible personel had to be graduate from radiology branch. On 5 May 2003, as referred to in article four of radiation safety regulations, educational seminar on the subject of personnel responsible for radiation protection and to protect personnel to be assigned in dangerous and extraordinary situations from radiation was given by Turkish Atomic Energy Authority (TAEK) in Safety and Training Department of TTK. It came on the scene that the personnel working in Health Department of TTK had to be trained and certificated by TAEK. For this purpose, TTK applied for the examination done by TAEA on 21 June 2003. But this application was not accepted as the personel had to be graduated from radiology branch.To renew the licience according to the radiation regulations, the application will be done again to TAEK after preparing necesarry conditions.The dosimeter results of the personnel at roentgen equipment in Health Department of TTK are measured and in the hand of TTK. For BERTHOLD type Cs-137 model equipment used for measuring density in filtration unit, Catalagz? Washery Plant has providing and using licence under the certificate of number KRY0049.02.001 dated on 26 May 2005 according to radiation safety regulations and statutes given by TAEA .As referred to in article 15 of radiation safety regulations published in official paper having number of 23999 and dated on 24 March 2006, the areas which can be subjected to over the annual dosage of 1mSv are named as

  15. A new oxidation flow reactor for measuring secondary aerosol formation of rapidly changing emission sources

    Science.gov (United States)

    Simonen, Pauli; Saukko, Erkka; Karjalainen, Panu; Timonen, Hilkka; Bloss, Matthew; Aakko-Saksa, Päivi; Rönkkö, Topi; Keskinen, Jorma; Dal Maso, Miikka

    2017-04-01

    Oxidation flow reactors (OFRs) or environmental chambers can be used to estimate secondary aerosol formation potential of different emission sources. Emissions from anthropogenic sources, such as vehicles, often vary on short timescales. For example, to identify the vehicle driving conditions that lead to high potential secondary aerosol emissions, rapid oxidation of exhaust is needed. However, the residence times in environmental chambers and in most oxidation flow reactors are too long to study these transient effects ( ˜ 100 s in flow reactors and several hours in environmental chambers). Here, we present a new oxidation flow reactor, TSAR (TUT Secondary Aerosol Reactor), which has a short residence time ( ˜ 40 s) and near-laminar flow conditions. These improvements are achieved by reducing the reactor radius and volume. This allows studying, for example, the effect of vehicle driving conditions on the secondary aerosol formation potential of the exhaust. We show that the flow pattern in TSAR is nearly laminar and particle losses are negligible. The secondary organic aerosol (SOA) produced in TSAR has a similar mass spectrum to the SOA produced in the state-of-the-art reactor, PAM (potential aerosol mass). Both reactors produce the same amount of mass, but TSAR has a higher time resolution. We also show that TSAR is capable of measuring the secondary aerosol formation potential of a vehicle during a transient driving cycle and that the fast response of TSAR reveals how different driving conditions affect the amount of formed secondary aerosol. Thus, TSAR can be used to study rapidly changing emission sources, especially the vehicular emissions during transient driving.

  16. Source selection for cluster weak lensing measurements in the Hyper Suprime-Cam survey

    Science.gov (United States)

    Medezinski, Elinor; Oguri, Masamune; Nishizawa, Atsushi J.; Speagle, Joshua S.; Miyatake, Hironao; Umetsu, Keiichi; Leauthaud, Alexie; Murata, Ryoma; Mandelbaum, Rachel; Sifón, Cristóbal; Strauss, Michael A.; Huang, Song; Simet, Melanie; Okabe, Nobuhiro; Tanaka, Masayuki; Komiyama, Yutaka

    2018-03-01

    We present optimized source galaxy selection schemes for measuring cluster weak lensing (WL) mass profiles unaffected by cluster member dilution from the Subaru Hyper Suprime-Cam Strategic Survey Program (HSC-SSP). The ongoing HSC-SSP survey will uncover thousands of galaxy clusters to z ≲ 1.5. In deriving cluster masses via WL, a critical source of systematics is contamination and dilution of the lensing signal by cluster members, and by foreground galaxies whose photometric redshifts are biased. Using the first-year CAMIRA catalog of ˜900 clusters with richness larger than 20 found in ˜140 deg2 of HSC-SSP data, we devise and compare several source selection methods, including selection in color-color space (CC-cut), and selection of robust photometric redshifts by applying constraints on their cumulative probability distribution function (P-cut). We examine the dependence of the contamination on the chosen limits adopted for each method. Using the proper limits, these methods give mass profiles with minimal dilution in agreement with one another. We find that not adopting either the CC-cut or P-cut methods results in an underestimation of the total cluster mass (13% ± 4%) and the concentration of the profile (24% ± 11%). The level of cluster contamination can reach as high as ˜10% at R ≈ 0.24 Mpc/h for low-z clusters without cuts, while employing either the P-cut or CC-cut results in cluster contamination consistent with zero to within the 0.5% uncertainties. Our robust methods yield a ˜60 σ detection of the stacked CAMIRA surface mass density profile, with a mean mass of M200c = [1.67 ± 0.05(stat)] × 1014 M⊙/h.

  17. Using NDACC column measurements of carbonyl sulfide to estimate its sources and sinks

    Science.gov (United States)

    Wang, Yuting; Marshall, Julia; Palm, Mathias; Deutscher, Nicholas; Roedenbeck, Christian; Warneke, Thorsten; Notholt, Justus; Baker, Ian; Berry, Joe; Suntharalingam, Parvadha; Jones, Nicholas; Mahieu, Emmanuel; Lejeune, Bernard; Hannigan, James; Conway, Stephanie; Strong, Kimberly; Campbell, Elliott; Wolf, Adam; Kremser, Stefanie

    2016-04-01

    Carbonyl sulfide (OCS) is taken up by plants during photosynthesis through a similar pathway as carbon dioxide (CO2), but is not emitted by respiration, and thus holds great promise as an additional constraint on the carbon cycle. It might act as a sort of tracer of photosynthesis, a way to separate gross primary productivity (GPP) from the net ecosystem exchange (NEE) that is typically derived from flux modeling. However the estimates of OCS sources and sinks still have significant uncertainties, which make it difficult to use OCS as a photosynthetic tracer, and the existing long-term surface-based measurements are sparse. The NDACC-IRWG measures the absorption of OCS in the atmosphere, and provides a potential long-term database of OCS total/partial columns, which can be used to evaluate OCS fluxes. We have retrieved OCS columns from several NDACC sites around the globe, and compared them to model simulation with OCS land fluxes based on the simple biosphere model (SiB). The disagreement between the measurements and the forward simulations indicates that (1) the OCS land fluxes from SiB are too low in the northern boreal region; (2) the ocean fluxes need to be optimized. A statistical linear flux model describing OCS is developed in the TM3 inversion system, and is used to estimate the OCS fluxes. We performed flux inversions using only NOAA OCS surface measurements as an observational constraint and with both surface and NDACC OCS column measurements, and assessed the differences. The posterior uncertainties of the inverted OCS fluxes decreased with the inclusion of NDACC data comparing to those using surface data only, and could be further reduced if more NDACC sites were included.

  18. Studies of longitudinal profile of electron bunches and impedance measurements at Indus-2 synchrotron radiation source

    Energy Technology Data Exchange (ETDEWEB)

    Garg, Akash Deep, E-mail: akash-deep@rrcat.gov.in [Beam Diagnostics Section (BDS), Indus Operations, Beam Dynamics and Diagnostics Division (IOBDD), Raja Ramanna Centre for Advanced Technology, Indore 452 013, M.P. (India); Homi Bhabha National Institute (HBNI) at Raja Ramanna Centre for Advanced Technology, Indore (India); Yadav, S.; Kumar, Mukesh; Shrivastava, B.B.; Karnewar, A.K.; Ojha, A.; Puntambekar, T.A. [Beam Diagnostics Section (BDS), Indus Operations, Beam Dynamics and Diagnostics Division (IOBDD), Raja Ramanna Centre for Advanced Technology, Indore 452 013, M.P. (India)

    2016-04-01

    Indus-2 is a 3rd generation synchrotron radiation source at the Raja Ramanna Centre for Advanced Technology (RRCAT) in India. We study the longitudinal profile of electrons in Indus-2 by using dual sweep synchroscan streak camera at visible diagnostic beamline. In this paper, the longitudinal profiles of electron bunch are analyzed by filling beam current in a single bunch mode. These studies are carried at injection energy (550 MeV) and at ramped beam energy (2.5 GeV). The effects of the wakefield generated interactions between the circulating electrons and the surrounding vacuum chamber are analyzed in terms of measured effects on longitudinal beam distribution. The impedance of the storage ring is obtained by fitting the solutions of Haissinski equation to the measured bunch lengthening with different impedance models. The impedance of storage ring obtained by a series R+L impedance model indicates a resistance (R) of 1350±125 Ω, an inductance (L) of 180±25 nH and broadband impedance of 2.69 Ω. These results are also compared with the values obtained from measured synchronous phase advancing and scaling laws. These studies are very useful in better understanding and control of the electromagnetic interactions.

  19. Radioactivity measurements in Egyptian Phosphate Mines and Their Significance As a Source of Hazardous Radioactive Waste

    International Nuclear Information System (INIS)

    Hussein, A.Z.; Hussein, M.I.; Abdel Hady, M.L.

    1999-01-01

    Phosphate mines that may contain radioactive traces in the composition of their ores represent source of hazardous radioactive waste in the environment. Radioactivity measurements have been conducted in nine underground phosphate mines in the Egyptian Eastern Desert in order to estimate the occupational radiation exposure of mine workers in those mining sites. Measurements were carried out of airborne radon and its short- lived decay products (progeny) and thoron progeny, as well as radiation from mines walls, ceilings and floors. Conventional, well established techniques, methods and instrumentation were used to make these measurements. Comparison of experimental data and theoretical predictions showed partial agreement between these two sets of data. This result is partly attributed to the complex layout of these mines, which causes undesirable ventilation conditions, such as recirculation airflow patterns, which could not be adequately identified or quantified. The radiation data obtained were used to estimate the maximum Annual Dose (MAD), and other important occupational radiation exposure variables. These calculations indicate that in eight out of the nine mines surveyed, the MAD exceeded (by a factor of up to 7) the maximum recommended level by ICRP 60. Numbers of suggestions are made in order to reduce the MAD in the affected mines. This study could help in the estimation of the environmental impact of these mine operations on the environment

  20. Studies on space charge neutralization and emittance measurement of beam from microwave ion source

    Energy Technology Data Exchange (ETDEWEB)

    Misra, Anuraag; Goswami, A.; Sing Babu, P.; Srivastava, S.; Pandit, V. S., E-mail: pandit@vecc.gov.in, E-mail: vspandit12@gmail.com [Variable Energy Cyclotron Centre, 1-AF, Bidhannagar, Kolkata 700 064 (India)

    2015-11-15

    A 2.45 GHz microwave ion source together with a beam transport system has been developed at VECC to study the problems related with the injection of high current beam into a compact cyclotron. This paper presents the results of beam profile measurement of high current proton beam at different degrees of space charge neutralisation with the introduction of neon gas in the beam line using a fine leak valve. The beam profiles have been measured at different pressures in the beam line by capturing the residual gas fluorescence using a CCD camera. It has been found that with space charge compensation at the present current level (∼5 mA at 75 keV), it is possible to reduce the beam spot size by ∼34%. We have measured the variation of beam profile as a function of the current in the solenoid magnet under the neutralised condition and used these data to estimate the rms emittance of the beam. Simulations performed using equivalent Kapchinsky-Vladimirsky beam envelope equations with space charge neutralization factor are also presented to interpret the experimental results.

  1. Measurement of the energy spectrum from the neutron source p lanned for IGISOL

    CERN Document Server

    Mattera, A; Rakopoulos, V; Lantz, M; Pomp, S; Solders, A; Al-Adili, A; Andersson, P; Hjalmarsson, A; Valldor-Blücher, B; Prokofiev, A; Passoth, E; Gentile, A; Bortot, D; Esposito, A; Introini, M V; Pola, A; Penttilä, H; Gorelov, D; Rinta-Antila, S

    2014-01-01

    We report on the characterisation measurements of the energ y spectra from a Be (p,xn) neutron source to be installed at the IGISOL-JYFLTRA P facility for studies of neutron-induced independent fission yields. The measurements were performed at The Svedberg Laboratory (Uppsala, Sweden), during 50 hours of beam-time in June, 2012. A 30 MeV p roton beam impinged on a mock-up of the proton-neutron converter; this was a 5 mm-thick beryllium disc inserted in an aluminium holder, with a 1-cm t hick layer of cool- ing water on the backside. The geometry of the mock-up has bee n chosen to reproduce the one that will be used as the IGISOL-JYFLTRAP so urce. During the experiment, two configurations for the neutron so urce have been used: a fast neutron field, produced using the bare target; an d a moderated field, obtained adding a 10 cm-thick Polyethylene block after the t arget assembly. The neutron fields have been measured using an Extended Range Bonner Sphere Spectrometer (ERBSS), able to simultaneously determine ...

  2. Measurement system of correlation functions of microwave single photon source in real time

    Science.gov (United States)

    Korenkov, A.; Dmitriev, A.; Astafiev, O.

    2018-02-01

    Several quantum setups, such as quantum key distribution networks[1] and quantum simulators (e.g. boson sampling), by their design rely on single photon sources (SPSs). These quantum setups were demonstrated to operate in optical frequency domain. However, following the steady advances in circuit quantum electrodynamics, a proposal has been made recently[2] to demonstrate boson sampling with microwave photons. This in turn requires the development of reliable microwave SPS. It's one of the most important characteristics are the first-order and the second-order correlation functions g1 and g2. The measurement technique of g1 and g2 is significantly different from that in the optical domain [3],[4] because of the current unavailability of microwave single-photon detectors. In particular, due to high levels of noise present in the system a substantial amount of statistics in needed to be acquired. This work presents a platform for measurement of g1 and g2 that processes the incoming data in real time, maximizing the efficiency of data acquisition. The use of field-programmable gate array (FPGA) electronics, common in similar experiments[3] but complex in programming, is avoided; instead, the calculations are performed on a standard desktop computer. The platform is used to perform the measurements of the first-order and the second-order correlation functions of the microwave SPS.

  3. The CENNS-10 liquid argon detector to measure CEvNS at the Spallation Neutron Source

    Science.gov (United States)

    Tayloe, R.

    2018-04-01

    The COHERENT collaboration is deploying a suite of low-energy detectors in a low-background corridor of the ORNL Spallation Neutron Source (SNS) to measure coherent elastic neutrino-nucleus scattering (CEvNS) on an array of nuclear targets employing different detector technologies. A measurement of CEvNS on different nuclei will test the N2-dependence of the CEvNS cross section and further the physics reach of the COHERENT effort. The first step of this program has been realized recently with the observation of CEvNS in a 14.6 kg CsI detector. Operation and deployment of Ge and NaI detectors are also underway. A 22 kg, single-phase, liquid argon detector (CENNS-10) started data-taking in Dec. 2016 and will provide results on CEvNS from a lighter nucleus. Initial results indicate that light output, pulse-shape discrimination, and background suppression are sufficient for a measurement of CEvNS on argon.

  4. Measurement of Dα sources for particle confinement time determination in TEXTOR

    International Nuclear Information System (INIS)

    Gray, D.S.; Boedo, J.A.; Conn, R.W.; Finken, K.H.; Mank, G.; Pospieszczyk, A.; Samm, U.

    1993-01-01

    An important quantity in the study of tokamak discharges is the global particle confinement time, defined for each ionic species i by the equation below, where N i is the total population of the species in the plasma and S i is the source rate (ionization rate) of the species: τ pi N i /(S i - dN i /dt). Of particular significance is the confinement time of the main plasma component, deuterium; here, in most cases of interest, the time derivative is negligible and the confinement time is given by N/S. The deuterium content N can be estimated from the electron content, measured by interferometry, if Z eff is known. A common method of estimating the fueling rate S is to measure the emission of D α light from recycling neutrals in the plasma boundary, since collisional-radiative modeling has shown that, for plasma conditions typical in the tokamak edge, the rate of ionization of D atoms and the rate of emission of D α photons are related by a factor that varies only weakly with electron density and temperature. This paper describes the use of a CCD video camera at TEXTOR for the purpose of spatially resolving the D α light in order to measure more accurately the total emission so that τ p can be determined reliably. (author) 5 refs., 5 figs

  5. Bubble detector's evaluation for neutron field measurement in a very known source

    Energy Technology Data Exchange (ETDEWEB)

    Ramalho, Eduardo; Silva, Ademir X. da, E-mail: ademir@nuclear.ufrj.b, E-mail: jdantas@con.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear; Reina, Luiz, E-mail: reina@ien.gov.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Facure, Alessandro, E-mail: facure@cnen.gov.b [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    Measurements on neutron fields, mainly for dosimetric purposes, have been a major concern for ionizing radiation workers, because of the radiation protection issues. The present work aims to study the using of bubble detectors in neutron dosimetry and the Bubble Detector Spectrometer (BDS) was chosen for this task. Several experiments were performed in order to obtain spectra from such devices and their respective analysis and then they were compared to those which were obtained by other ways. An Am-Be calibration neutron source from Instituto de Radioprotecao e Dosimetria/Comissao Nacional de Energia Nuclear (IRD/CNEN) was used and its spectrum was compared to the one obtained by BDS. The possibility of the use of such devices as ambient dosimeters was also evaluated. Despite the uncertainties, especially in the lowest energy thresholds, the spectrum from BDS is in good agreement with the known ones and the use of BDS as a dosimeter demands a more detailed study due to some characteristics of the Am-Be source that produce high uncertainties in low energy thresholds. (author)

  6. Measurements of strongly localized potential well profiles in an inertial electrostatic fusion neutron source

    International Nuclear Information System (INIS)

    Yoshikawa, K.; Takiyama, K.; Koyama, T.

    2001-01-01

    Direct measurements of localized electric fields are made by the laser-induced fluorescence (LIF) method by use of the Stark effects in the central cathode core region of an Inertial-Electrostatic Confinement Fusion (IECF) neutron (proton) source, which is expected for various applications, such as luggage security inspection, non-destructive testing, land mine detector, or positron emitter production for cancer detection, currently producing continuously about 10 7 n/sec D-D neutrons. Since 1967 when the first fusion reaction was successfully proved experimentally in a very compact IECF device, potential well formation due to space charge associated with spherically converging ion beams has been a central key issue to be clarified in the beam-beam colliding fusion, which is the major mechanism of the IECF neutron source. Many experiments, but indirect, were made so far to clarify the potential well, but none of them produced definitive evidence, however. Results by the present LIF method show a double well potential profile with a slight concave for ion beams with relatively larger angular momenta, whereas for ions with smaller angular momenta, potential but much steeper peak to develop. (author)

  7. Tropical forests are a net carbon source based on aboveground measurements of gain and loss.

    Science.gov (United States)

    Baccini, A; Walker, W; Carvalho, L; Farina, M; Sulla-Menashe, D; Houghton, R A

    2017-10-13

    The carbon balance of tropical ecosystems remains uncertain, with top-down atmospheric studies suggesting an overall sink and bottom-up ecological approaches indicating a modest net source. Here we use 12 years (2003 to 2014) of MODIS pantropical satellite data to quantify net annual changes in the aboveground carbon density of tropical woody live vegetation, providing direct, measurement-based evidence that the world's tropical forests are a net carbon source of 425.2 ± 92.0 teragrams of carbon per year (Tg C year -1 ). This net release of carbon consists of losses of 861.7 ± 80.2 Tg C year -1 and gains of 436.5 ± 31.0 Tg C year -1 Gains result from forest growth; losses result from deforestation and from reductions in carbon density within standing forests (degradation or disturbance), with the latter accounting for 68.9% of overall losses. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  8. Security measurements and radiological protection in the source panoramic irradiators and storage in pool

    International Nuclear Information System (INIS)

    Del Valle O, C.

    1996-01-01

    The aim of this paper is to investigate and to study the safety and protecting measurements that must be taken into account in the design and the use of panoramic source irradiators with wet storage or pool, concerning to category IV. The generic characteristics in plants of kind, as well as their description, are mentioned in this paper. The devices, that comply the security and control systems based on their redundancy, diversity and independence, are examined. Likewise, it describes the design requirements of the overcast, of the irradiators, of the source frame, of the transporting system of product, of the procedure access, of the security system of the irradiator shelf control, of the irradiation room, of the irradiation storage pool, of the ventilation system, for the protection in case of fire of fire, for electric energy failures, for the warning symbols and signs. It contains scope about the organization and responsibilities that must be taken into account in plants of this type. A detailed plan has been made for its operation and maintenance, enclosing instructions and registers for this reason. The statement of emergency events and their respective answers, the analysis of cases and reasons that causes accidents and its implementation and regular inspection procedures for the improvement of the plant are also studied. (author). 2 refs

  9. Characterization of a pulsed x-ray source for fluorescent lifetime measurements

    International Nuclear Information System (INIS)

    Blankespoor, S.C.; Derenzo, S.E.; Moses, W.W.; Rossington, C.S.; Ito, M.; Oba, K.

    1994-01-01

    To search for new, fast, inorganic scintillators, the authors have developed a bench-top pulsed x-ray source for determining fluorescent lifetimes and wavelengths of compounds in crystal or powdered form. This source uses a light-excited x-ray tube which produces x-rays when light from a laser diode strikes its photocathode. The x-ray tube has a tungsten anode, a beryllium exit window, a 30 kV maximum tube bias, and a 50 μA maximum average cathode current. The laser produces 3 x 10 7 photons at 650 nm per ∼100 ps pulse, with up to 10 7 pulses/sec. The time spread for the laser diode, x-ray tube, and a microchannel plate photomultiplier tube is less than 120 ps fwhm. The mean x-ray energy at tube biases of 20, 25, and 30 kV is 9.4, 10.3, and 11.1 keV, respectively. The authors measured 140, 230, and 330 x-ray photons per laser diode pulse per steradian, at tube biases of 20, 25, and 30 kV, respectively. Background x-rays due to dark current occur at a rate of 1 x 10 6 and 3 x 10 6 photons/sec/steradian at biases of 25 and 30 kV, respectively. Data characterizing the x-ray output with an aluminum filter in the x-ray beam are also presented

  10. Technique for measuring cooling patterns in ion source grids by infrared scanning

    International Nuclear Information System (INIS)

    Grisham, L.R.; Eubank, H.P.; Kugel, H.W.

    1980-02-01

    Many plasma sources designed for neutral beam injection heating of plasmas now employ copper beam acceleration grids which are water-cooled by small capillary tubes fed from one or more headers. To prevent thermally-induced warpage of these grids it is essential that one be able to detect inhomogeneities in the cooling. Due to the very strong thermal coupling between adjacent cooling lines and the concomitant rapid equilibration times, it is not practical to make such measurements in a direct manner with a contact thermometer. We have developed a technique whereby we send a burst of hot water through an initially cool grid, followed by a burst of cool water, and record the transient thermal behavior usng an infrared television camera. This technique, which would be useful for any system with cooling paths that are strongly coupled thermally, has been applied to a number of sources built for the PLT and PDX tokamaks, and has proven highly effective in locating cooling deficiencies and blocked capillary tubes

  11. Chorus source region localization in the Earth's outer magnetosphere using THEMIS measurements

    Directory of Open Access Journals (Sweden)

    O. Agapitov

    2010-06-01

    Full Text Available Discrete ELF/VLF chorus emissions, the most intense electromagnetic plasma waves observed in the Earth's radiation belts and outer magnetosphere, are thought to propagate roughly along magnetic field lines from a localized source region near the magnetic equator towards the magnetic poles. THEMIS project Electric Field Instrument (EFI and Search Coil Magnetometer (SCM measurements were used to determine the spatial scale of the chorus source localization region on the day side of the Earth's outer magnetosphere. We present simultaneous observations of the same chorus elements registered onboard several THEMIS spacecraft in 2007 when all the spacecraft were in the same orbit. Discrete chorus elements were observed at 0.15–0.25 of the local electron gyrofrequency, which is typical for the outer magnetosphere. We evaluated the Poynting flux and wave vector distribution and obtained chorus wave packet quasi-parallel propagation to the local magnetic field. Amplitude and phase correlation data analysis allowed us to estimate the characteristic spatial correlation scale transverse to the local magnetic field to be in the 2800–3200 km range.

  12. Gas Injection And Fast Pressure-Rise Measurements For The Linac4 H− Source

    CERN Document Server

    Mahner, E; Lettry, J; Mattei, S; O'Neil, M; Neupert, H; Pasquino, C; Schmitzer, C

    2013-01-01

    In the era of the Large Hadron Collider, the CERN injector complex comprising the 34 years old Linac2 with its primary proton source, is presently upgraded with a new linear accelerator for H− (Linac4). The design, construction, and test of volume production and cesiated RF-driven H− ion sources is presently ongoing with the final goal of producing an H− beam with 80 mA beam current, 45 keV beam energy, 500 s pulse length, and a repetition rate of 2 Hz. In order to have quantitative information of the hydrogen gas density at the moment of plasma ignition the dynamic vacuum properties of the plasma generator were studied experimentally. We describe the experimental setup and present fast pressure-rise measurements for different parameters of the gas injection system, such as gas species (H2, He, N2, Ar), piezo valve voltage pulse length (200 - 500 s), and injection pressure (400 - 2800 mbar). The obtained data are compared with a conductance model of the plasma generator.

  13. Development of AN Open-Source Automatic Deformation Monitoring System for Geodetical and Geotechnical Measurements

    Science.gov (United States)

    Engel, P.; Schweimler, B.

    2016-04-01

    The deformation monitoring of structures and buildings is an important task field of modern engineering surveying, ensuring the standing and reliability of supervised objects over a long period. Several commercial hardware and software solutions for the realization of such monitoring measurements are available on the market. In addition to them, a research team at the Neubrandenburg University of Applied Sciences (NUAS) is actively developing a software package for monitoring purposes in geodesy and geotechnics, which is distributed under an open source licence and free of charge. The task of managing an open source project is well-known in computer science, but it is fairly new in a geodetic context. This paper contributes to that issue by detailing applications, frameworks, and interfaces for the design and implementation of open hardware and software solutions for sensor control, sensor networks, and data management in automatic deformation monitoring. It will be discussed how the development effort of networked applications can be reduced by using free programming tools, cloud computing technologies, and rapid prototyping methods.

  14. Reconstruction of Chernobyl source parameters using gamma dose rate measurements in town Pripjat

    Directory of Open Access Journals (Sweden)

    M. M. Talerko

    2010-06-01

    Full Text Available With the help of mathematical modeling of atmospheric transport the calculations of accidental release dispersion from the Chernobyl NPP to town Pripjat during period from 26 till 29 April 1986 have been carried out. Data of gamma rate measurements which was made in 31 points of the town were used. Based on the solution of atmospheric transport inverse problem the reconstruction of Chernobyl source parameters has been made including release intensity and effective source height. The input of main dose-forming radionuclides into the exposure dose during the first 40 hours after the accident (the period of population residence in the town before the evacuation has been estimated. According to the calculations the 131I deposition density averaged over the town territory was about 5.2 × 104 kBq/m2 (on 29.04.86. Minimum and maximum 131I deposition values were 2.8 × 104 kBq/m2 (western part, distance to the unit is 4.5 km and 1.2 × 105 kBq/m2 (north-eastern part of town, 2 km from the unit accordingly. For the moment of the evacuation dated April 27, deposition values were about 90 percent of these values.

  15. Reference-Frame-Independent and Measurement-Device-Independent Quantum Key Distribution Using One Single Source

    Science.gov (United States)

    Li, Qian; Zhu, Changhua; Ma, Shuquan; Wei, Kejin; Pei, Changxing

    2018-04-01

    Measurement-device-independent quantum key distribution (MDI-QKD) is immune to all detector side-channel attacks. However, practical implementations of MDI-QKD, which require two-photon interferences from separated independent single-photon sources and a nontrivial reference alignment procedure, are still challenging with current technologies. Here, we propose a scheme that significantly reduces the experimental complexity of two-photon interferences and eliminates reference frame alignment by the combination of plug-and-play and reference frame independent MDI-QKD. Simulation results show that the secure communication distance can be up to 219 km in the finite-data case and the scheme has good potential for practical MDI-QKD systems.

  16. Exposition by inhalation to the formaldehyde in the air. Source, measures and concentrations; Exposition par inhalation au formaldehyde dans l'air. Source, mesures et concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Del Gratta, F.; Durif, M.; Fagault, Y.; Zdanevitch, I

    2004-12-15

    This document presents the main techniques today available to characterize the formaldehyde concentrations in the air for different contexts: urban and rural areas or around industrial installations but also indoor and occupational area. It provides information to guide laboratories and research departments. A synthesis gives also the main emissions sources of these compounds as reference concentrations measured in different environments. (A.L.B.)

  17. The online measured black carbon aerosol and source orientations in the Nam Co region, Tibet.

    Science.gov (United States)

    Zhang, Xin; Ming, Jing; Li, Zhongqin; Wang, Feiteng; Zhang, Guoshuai

    2017-11-01

    Equivalent black carbon (eBC) mass concentrations were measured by an aethalometer (AE-31) in the Nam Co, central Tibet from 2010 to 2014. Different from previous filter-sampling studies (Ming et al., J Environ Sci 22(11):1748-1756, 2010; Zhao et al., Environ Sci Pollut Res 20:5827-5838, 2013), the first high-resolution online eBC measurement conducted in central Tibet is reported here, allowing to discuss the diurnal variations as well as seasonal variabilities of eBC. Average daily eBC concentration was 74 ± 50 ng/m 3 , reflecting a global background level. Meteorological conditions influenced eBC concentrations largely at seasonal scale, which are higher in February-May but lower in June-January. The highest eBC concentrations (greater than 210 ng/m 3 ) were more associated with the W and WSW winds smaller than 6 m/s. The diurnal variations of eBC showed plateaus from 10:00 to 15:00 with seasonal variations, associated with local anthropogenic activities, such as indigenous Tibetan burning animal waste and tourism traffic. The PBLHs showed a co-variance with eBC concentrations, implicating close sources. The aerosol optical depths derived from the MODIS data over the Nam Co Observatory Station (NCOS)-included sub-area (30° N-40° N, 90° E-100° E) showed significant relationship with eBC concentrations. This suggests that nearby or short-distance sources other than long-distance transported pollutants could be important contributors to eBC concentrations at the NCOS, different from the conclusions suggested by previous studies.

  18. Characteristics of prepared gamma-ray calibration sources for radioactivity measurement of environmental and radiation control samples

    International Nuclear Information System (INIS)

    Samat, S.B.; Oi, Yoshihiro; Taki, Mitsumasa; Manabe, Iwao; Yoshida, Makoto; Minami, Kentaro

    1995-03-01

    Several types of calibration source having different density were prepared using one or combinations of those materials, namely foam cement, liquid, glass beads, polystyrene foam bead and hard plastic bead for gamma-ray spectrometry of the samples with different densities and shapes(variable height with constant base area). For each type of the source, a few sources were prepared to examine characteristics in such cases as (a) different heights but constant density, and (b) constant height and constant density. For the foam cement source, several sources with different densities and a constant height were prepared. All the sources were measured with a gamma-ray spectrometry system and the results were discussed. This report also presents the results obtained from the experiments for the evaluation of (1) the variation of detector efficiency-energy with gamma-ray energy, and (2) the variation of detector efficiency with density of the sources. (author)

  19. SU-E-I-79: Source Geometry Dependence of Gamma Well-Counter Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Park, M; Belanger, A; Kijewski, M [Brigham and Women’s Hospital and Harvard Medical School, Boston, MA (United States)

    2015-06-15

    Purpose: To determine the effect of liquid sample volume and geometry on counting efficiency in a gamma well-counter, and to assess the relative contributions of sample geometry and self-attenuation. Gamma wellcounters are standard equipment in clinical and preclinical studies, for measuring patient blood radioactivity and quantifying animal tissue uptake for tracer development and other purposes. Accurate measurements are crucial. Methods: Count rates were measured for aqueous solutions of 99m- Tc at four liquid volume values in a 1-cm-diam tube and at six volume values in a 2.2-cm-diam vial. Total activity was constant for all volumes, and data were corrected for decay. Count rates from a point source in air, supported by a filter paper, were measured at seven heights between 1.3 and 5.7 cm from the bottom of a tube. Results: Sample volume effects were larger for the tube than for the vial. For the tube, count efficiency relative to a 1-cc volume ranged from 1.05 at 0.05 cc to 0.84 at 3 cc. For the vial, relative count efficiency ranged from 1.02 at 0.05 cc to 0.87 at 15 cc. For the point source, count efficiency relative to 1.3 cm from the tube bottom ranged from 0.98 at 1.8 cm to 0.34 at 5.7 cm. The relative efficiency of a 3-cc liquid sample in a tube compared to a 1-cc sample is 0.84; the average relative efficiency for the solid sample in air between heights in the tube corresponding to the surfaces of those volumes (1.3 and 4.8 cm) is 0.81, implying that the major contribution to efficiency loss is geometry, rather than attenuation. Conclusion: Volume-dependent correction factors should be used for accurate quantitation radioactive of liquid samples. Solid samples should be positioned at the bottom of the tube for maximum count efficiency.

  20. Context matters! sources of variability in weekend physical activity among families: a repeated measures study

    Directory of Open Access Journals (Sweden)

    Robert J. Noonan

    2017-04-01

    Full Text Available Abstract Background Family involvement is an essential component of effective physical activity (PA interventions in children. However, little is known about the PA levels and characteristics of PA among families. This study used a repeated measures design and multiple data sources to explore the variability and characteristics of weekend PA among families. Methods Families (including a ‘target’ child aged 9–11 years, their primary caregiver(s and siblings aged 6–8 years were recruited through primary schools in Liverpool, UK. Participants completed a paper-based PA diary and wore an ActiGraph GT9X accelerometer on their left wrist for up to 16 weekend days. ActiGraph.csv files were analysed using the R-package GGIR version 1.1–4. Mean minutes of moderate-to-vigorous PA (MVPA for each weekend of measurement were calculated using linear mixed models, and variance components were estimated for participant (inter-individual, weekend of measurement, and residual error (intra-individual. Intraclass correlation coefficients (ICC were calculated from the proportion of total variance accounted for by inter-individual sources, and used as a measure of reliability. Diary responses were summed to produce frequency counts. To offer contextual insight into weekend PA among family units, demographic, accelerometer, and diary data were combined to form two case studies representative of low and high active families. Results Twenty-five participants from 7 families participated, including 7 ‘target’ children (mean age 9.3 ± 1.1 years, 4 boys, 6 siblings (mean age 7.2 ± 0.7 years; 4 boys and 12 adults (7 mothers and 5 fathers. There was a high degree of variability in target children’s (ICC = 0.55, siblings (ICC = 0.38, and mothers’ MVPA (ICC = 0.58, but not in fathers’ MVPA (ICC = 0.83. Children’s weekend PA was mostly unstructured in nature and undertaken with friends, whereas a greater proportion of parents’ weekend