WorldWideScience

Sample records for measure blood pressure

  1. Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure.

    NARCIS (Netherlands)

    Kiers, H.D.; Hofstra, J.M.; Wetzels, J.F.M.

    2008-01-01

    Mean arterial pressure (MAP) is often used as an index of overall blood pressure. In recent years, the use of automated oscillometric blood pressure measurement devices is increasing. These devices directly measure and display MAP; however, MAP is often calculated from systolic blood pressure (SBP)

  2. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    Science.gov (United States)

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  3. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    Science.gov (United States)

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  4. Blood Pressure Measurement: Clinic, Home, Ambulatory, and Beyond

    Science.gov (United States)

    Drawz, Paul E.; Abdalla, Mohamed; Rahman, Mahboob

    2014-01-01

    Blood pressure has traditionally been measured in the clinic setting using the auscultory method and a mercury sphygmomanometer. Technological advances have led to improvements in measuring clinic blood pressure and allowed for measuring blood pressures outside the clinic. This review outlines various methods for evaluating blood pressure and the clinical utility of each type of measurement. Home blood pressures and 24 hour ambulatory blood pressures have improved our ability to evaluate risk for target organ damage and hypertension related morbidity and mortality. Measuring home blood pressures may lead to more active participation in health care by patients and has the potential to improve blood pressure control. Ambulatory blood pressure monitoring enables the measuring nighttime blood pressures and diurnal changes, which may be the most accurate predictors of risk associated with elevated blood pressure. Additionally, reducing nighttime blood pressure is feasible and may be an important component of effective antihypertensive therapy. Finally, estimating central aortic pressures and pulse wave velocity are two of the newer methods for assessing blood pressure and hypertension related target organ damage. PMID:22521624

  5. Home blood pressure measurement in elderly patients with cognitive impairment: comparison of agreement between relative-measured blood pressure and automated blood pressure measurement.

    Science.gov (United States)

    Plichart, Matthieu; Seux, Marie-Laure; Caillard, Laure; Chaussade, Edouard; Vidal, Jean-Sébastien; Boully, Clémence; Hanon, Olivier

    2013-08-01

    Home blood pressure measurement (HBPM) is recommended by guidelines for hypertension management. However, this method might be difficult to use in elderly individuals with cognitive disorders. Our aim was to assess the agreement and the feasibility of HBPM by a relative as compared with 24-h ambulatory blood pressure monitoring (ABPM) in elderly patients with dementia. Sixty outpatients with dementia aged 75 years and older with office hypertension (≥140/90 mmHg) were subjected successively to HBPM by a trained relative and 24-h ABPM. The order of the two methods was randomized. Current guidelines' thresholds for the diagnosis of hypertension were used. The mean (SD) age of the patients was 80.8 (6.1) years (55% women) and the mean (SD) mini-mental state examination score was 20.1 (6.9). The feasibility of relative-HBPM was very high, with a 97% success rate (defined by ≥12/18 measurements reported). The blood pressure measurements were highly correlated between the two methods (r=0.75 and 0.64 for systolic blood pressure and diastolic blood pressure, respectively; Pmethods for the diagnosis of sustained hypertension and white-coat hypertension was excellent (overall agreement, 92%; κ coefficient, 0.81; 95% CI, 0.61-0.93). Similar results were found for daytime-ABPM. In cognitively impaired elderly patients, HBPM by a relative using an automated device was a good alternative to 24-h ABPM.

  6. Blood pressure and anthropometric measurements in healthy ...

    African Journals Online (AJOL)

    Methods. We measured the blood pressures of 650 healthy, randomly ... In addition, blood pressure measurement should be a part of the routine clinical examination of children. ... familial risk factors.2 ... common cause of elevated blood pressure in children.4 They ... sphygmomanometer (Accoson, hospital model BS 274,.

  7. [Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm].

    Science.gov (United States)

    Saul, F; Aristidou, Y; Klaus, D; Wiemeyer, A; Lösse, B

    1995-09-01

    Indirectly measured blood pressure at the wrist or upper arm was compared with directly measured values in the aortic arch during routinely performed diagnostic cardiac catheterization in 100 patients (31-80 years, mean 59.3 years, 60% males). The noninvasive measurements were carried out by oscillometric devices, NAiS Blood Pressure Watch for measurements at the wrist, and Hestia OZ80 at the upper arm. Systolic blood pressure measured at the wrist was 4.3 +/- 14.1 mm Hg, and the diastolic value 6.0 +/- 8.9 mm Hg higher than when measured at the aortic arch; the difference was significant in both cases. Correlation coefficients were 0.85 for systolic and 0.71 for diastolic blood pressure. In 16% of the patients the systolic blood pressure at the wrist differed more than +/- 20 mm Hg. The diastolic blood pressure at the wrist measured more than +/- 20 mm Hg higher than in the aorta in 5% of the patients. At the upper arm mean systolic values were not different to the aorta. The diastolic pressure was 9.3 +/- 9.8 mm Hg higher in the aorta than at the upper arm. To verify the accuracy of values measured with the NAiS Blood Pressure Watch compared with the standard technique at the upper arm, sequential measurements were made at wrist and ipsilateral upper arm in the same group of 100 patients. The systolic blood pressure at the left wrist was 3.4 +/- 13.3 mm Hg higher and the diastolic pressure 3.8 +/- 9.5 mm Hg lower than at the upper arm. Only 53% of systolic values lay within a range of +/- 10 mm Hg. The correspondence between wrist and upper arm values was better for diastolic blood pressure, the values differing by less than +/- 10 mm Hg in two-thirds of patients. Self-measurement of arterial blood pressure with an oscillometric device at the wrist can be recommended only in individual cases with a difference of simultaneously measured values at the upper arm of less than +/- 10 mm Hg for systolic and diastolic blood pressures. The standard method for indirectly

  8. Context-aware patient guidance during blood pressure self-measurement

    DEFF Research Database (Denmark)

    Sandager, Puk; Lindahl, Camilla; Schlütter, Jacob Mørup

    2013-01-01

    The importance of accurate measurement of blood pressure in the screening and management of hypertension during pregnancy is well established. Blood pressure levels can be measured manually by healthcare staff or by using a blood pressure self-measurement device, either at home or in the clinic...... the blood pressure self-measurement process. Preliminary results indicate that such active and context-aware guidance leads to more reliable measurements by inhibiting non-adherent patient behavior...

  9. Palpatory method of measuring diastolic blood pressure

    Directory of Open Access Journals (Sweden)

    Dinesh Sahu

    2010-01-01

    Conclusion: The palpatory method would be very useful where frequent blood pressure measurement are being done manually like in wards, in busy OPD, patient on treadmill and also whenever stethoscope is not available. The blood pressure can be measured in noisy environment too.

  10. Blood pressure measurement: one arm or both arm?

    Science.gov (United States)

    Kulkarni, Prasad K; Shekhar, Susheela; Reddy, B N; Nirmala, B C

    2011-09-01

    Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.

  11. Peripheral vascular effects on auscultatory blood pressure measurement.

    Science.gov (United States)

    Rabbany, S Y; Drzewiecki, G M; Noordergraaf, A

    1993-01-01

    Experiments were conducted to examine the accuracy of the conventional auscultatory method of blood pressure measurement. The influence of the physiologic state of the vascular system in the forearm distal to the site of Korotkoff sound recording and its impact on the precision of the measured blood pressure is discussed. The peripheral resistance in the arm distal to the cuff was changed noninvasively by heating and cooling effects and by induction of reactive hyperemia. All interventions were preceded by an investigation of their effect on central blood pressure to distinguish local effects from changes in central blood pressure. These interventions were sufficiently moderate to make their effect on central blood pressure, recorded in the other arm, statistically insignificant (i.e., changes in systolic [p cooling experiments was statistically significant (p < 0.001). Moreover, both measured systolic (p < 0.004) and diastolic (p < 0.001) pressure decreases during the reactive hyperemia experiments were statistically significant. The findings demonstrate that alteration in vascular state generates perplexing changes in blood pressure, hence confirming experimental observations by earlier investigators as well as predictions by our model studies.

  12. The optimal scheme of self blood pressure measurement as determined from ambulatory blood pressure recordings

    NARCIS (Netherlands)

    Verberk, Willem J.; Kroon, Abraham A.; Kessels, Alfons G. H.; Lenders, Jacques W. M.; Thien, Theo; van Montfrans, Gert A.; Smit, Andries J.; de Leeuw, Peter W.

    Objective To determine how many self-measurements of blood pressure (BP) should be taken at home in order to obtain a reliable estimate of a patient's BP. Design Participants performed self blood pressure measurement (SBPM) for 7 days (triplicate morning and evening readings). In all of them, office

  13. TREATMENT OF HYPERTENSION USING TELEMEDICAL HOME BLOOD PRESSURE MEASUREMENTS

    DEFF Research Database (Denmark)

    Hoffmann-Petersen, N; Lauritzen, T; Bech, J N

    2015-01-01

    OBJECTIVE: Telemonitoring of home blood pressure measurements (TBPM) is a new and promising supplement to diagnosis, control and treatment of hypertension. We wanted to compare the outcome of antihypertensive treatment based on TBPM and conventional monitoring of blood pressure. DESIGN AND METHOD...... of the measurements and subsequent communication by telephone or E-mail. In the control group, patients received usual care. Primary outcome was reduction in daytime ambulatory blood pressure measurements (ABPM) from baseline to 3 months' follow-up. RESULTS: In both groups, daytime ABPM decreased significantly....../181), p = 0.34. Blood pressure reduction in the TBPM group varied with the different practices. CONCLUSIONS: No further reduction in ABPM or number of patients reaching blood pressure targets was observed when electronic transmission of TBPM was applied in the treatment of hypertension by GPs. Thus...

  14. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

    Directory of Open Access Journals (Sweden)

    Glik Zehava

    2009-10-01

    Full Text Available Abstract Background Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. Methods In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1 determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2 discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. Results Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. Conclusion The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.

  15. Serial blood pressure measurements

    Directory of Open Access Journals (Sweden)

    N.R. Koehler

    2002-05-01

    Full Text Available The objective of the present investigation was to study the effects of a 60-s interval of venous congestion between two noninvasive measurements of arterial blood pressure (ABP on the fluctuation of ABP, assessed by the standard deviation of the differences between two readings. ABP was measured in 345 successive patients, at rest, four times each. For 269 participants, one pair of readings was obtained with a 60-s interval and the other pair without an interval. For 76 patients, the first pair was read at the same interval, and the second pair had venous congestion interposed and there was no waiting interval. There was no increased ABP oscillation, either when there was no interval between ABP readings, or when venous congestion was interposed compared to pairs of ABP measurements performed with a 60-s interval. There was no increase in ABP oscillations when successive ABP readings were taken without an interval or even with venous congestion interposed. Contrary to the present belief, there seems to be no loss of reliability when blood pressure recordings are taken immediately one after another, in the clinical setting.

  16. Comparison of ambulatory blood pressure monitoring and office blood pressure measurements in obese children and adolescents.

    Science.gov (United States)

    Renda, Rahime

    2018-04-01

    Obesity in adults has been related to hypertension and abnormal nocturnal dipping of blood pressure, which are associated with poor cardiovascular and renal outcomes. Here, we aimed to resolve the relationship between the degree of obesity, the severity of hypertension and dipping status on ambulatory blood pressure in obese children. A total 72 patients with primary obesity aged 7 to 18 years (mean: 13.48 ± 3.25) were selected. Patients were divided into three groups based on body mass index (BMİ) Z-score. Diagnosis and staging of ambulatory hypertension based on 24-h blood pressure measurements, obtained from ambulatory blood pressure monitoring. Based on our ambulatory blood pressure data, 35 patients (48.6%) had hypertension, 7 (20%) had ambulatory prehypertension, 21 (60%) had hypertension, and 7 patients (20%) had severe ambulatory hypertension. There was a significant relationship between severity of hypertension and the degree of obesity (p lood pressure results and loads were similar between groups. Diastolic and mean arterial blood pressure levels during the night, diastolic blood pressure loads, and heart rate during the day were significantly higher in Group 3 (p lood pressure at night, mean arterial pressure at night, diastolic blood pressure loads and heart rate at day. Increase in BMI Z-score does not a significant impact on daytime blood pressure and nocturnal dipping status.

  17. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.

    Science.gov (United States)

    Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio

    2004-06-01

    It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (pforearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (pforearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.

  18. [Invasive arterial blood pressure measurement using an aneroid pressure system in cattle].

    Science.gov (United States)

    Mosing, M; Franz, S; Iff, I; Schwendenwein, I

    2009-06-01

    The aim of this study was to compare the results of invasive arterial blood pressure measurement using an electronic pressure transducer (EPT) or an aneroid pressure system (APS) in cattle. A catheter was placed in the auricular artery of 11 adult cattle and connected to a pressure transducer via pressure line. The aneroid system was connected to the same catheter using a three-way stop-cock in the pressure line. On five occasions three consecutive measurements were performed with the APS. The mean blood pressure values of the EPT were recorded before each individual measurement. Values from each device were compared using Passing and Bablok regression of agreement and a Bland and Altman difference plot. One hundred and forty-seven paired measurements were analysed. The average bias between the two methods (EPT vs. APS) was -1.6 mmHg (95 % confidence interval [CI]: -3.0 to -0.2 mmHg). The coefficient of correlation was 1.0084. The aneroid system showed an almost perfect agreement with the EPT. This study shows that it can be used in a clinical setting as well as under field conditions to measure arterial blood pressure in cattle.

  19. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.

    Science.gov (United States)

    Gholamhosseini, Hamid; Meintjes, Andries; Baig, Mirza; Linden, Maria

    2016-01-01

    The increasing availability of low cost and easy to use personalized medical monitoring devices has opened the door for new and innovative methods of health monitoring to emerge. Cuff-less and continuous methods of measuring blood pressure are particularly attractive as blood pressure is one of the most important measurements of long term cardiovascular health. Current methods of noninvasive blood pressure measurement are based on inflation and deflation of a cuff with some effects on arteries where blood pressure is being measured. This inflation can also cause patient discomfort and alter the measurement results. In this work, a mobile application was developed to collate the PhotoPlethysmoGramm (PPG) waveform provided by a pulse oximeter and the electrocardiogram (ECG) for calculating the pulse transit time. This information is then indirectly related to the user's systolic blood pressure. The developed application successfully connects to the PPG and ECG monitoring devices using Bluetooth wireless connection and stores the data onto an online server. The pulse transit time is estimated in real time and the user's systolic blood pressure can be estimated after the system has been calibrated. The synchronization between the two devices was found to pose a challenge to this method of continuous blood pressure monitoring. However, the implemented continuous blood pressure monitoring system effectively serves as a proof of concept. This combined with the massive benefits that an accurate and robust continuous blood pressure monitoring system would provide indicates that it is certainly worthwhile to further develop this system.

  20. Auscultatory versus oscillometric measurement of blood pressure in octogenarians

    DEFF Research Database (Denmark)

    Rosholm, Jens-Ulrik; Pedersen, Sidsel Arnspang; Matzen, Lars

    2012-01-01

    Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement.......Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement....

  1. Signal quality measures for unsupervised blood pressure measurement

    International Nuclear Information System (INIS)

    Abdul Sukor, J; Redmond, S J; Lovell, N H; Chan, G S H

    2012-01-01

    Accurate systolic and diastolic pressure estimation, using automated blood pressure measurement, is difficult to achieve when the transduced signals are contaminated with noise or interference, such as movement artifact. This study presents an algorithm for automated signal quality assessment in blood pressure measurement by determining the feasibility of accurately detecting systolic and diastolic pressures when corrupted with various levels of movement artifact. The performance of the proposed algorithm is compared to a manually annotated reference scoring (RS). Based on visual representations and audible playback of Korotkoff sounds, the creation of the RS involved two experts identifying sections of the recorded sounds and annotating sections of noise contamination. The experts determined the systolic and diastolic pressure in 100 recorded Korotkoff sound recordings, using a simultaneous electrocardiograph as a reference signal. The recorded Korotkoff sounds were acquired from 25 healthy subjects (16 men and 9 women) with a total of four measurements per subject. Two of these measurements contained purposely induced noise artifact caused by subject movement. Morphological changes in the cuff pressure signal and the width of the Korotkoff pulse were extracted features which were believed to be correlated with the noise presence in the recorded Korotkoff sounds. Verification of reliable Korotkoff pulses was also performed using extracted features from the oscillometric waveform as recorded from the inflatable cuff. The time between an identified noise section and a verified Korotkoff pulse was the key feature used to determine the validity of possible systolic and diastolic pressures in noise contaminated Korotkoff sounds. The performance of the algorithm was assessed based on the ability to: verify if a signal was contaminated with any noise; the accuracy, sensitivity and specificity of this noise classification, and the systolic and diastolic pressure

  2. Blood pressure

    Science.gov (United States)

    Normal blood pressure is important for proper blood flow to the body's organs and tissues. The force of the blood on the walls of the arteries is called blood pressure. Blood pressure is measured both as the heart ...

  3. Challenges in standardization of blood pressure measurement at the population level.

    Science.gov (United States)

    Tolonen, Hanna; Koponen, Päivikki; Naska, Androniki; Männistö, Satu; Broda, Grazyna; Palosaari, Tarja; Kuulasmaa, Kari

    2015-04-10

    Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed. The European Health Examination Survey (EHES) Pilot project was conducted in 2009-2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization. The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement. It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.

  4. Development of a Blood Pressure Measurement Instrument with Active Cuff Pressure Control Schemes

    Directory of Open Access Journals (Sweden)

    Chung-Hsien Kuo

    2017-01-01

    Full Text Available This paper presents an oscillometric blood pressure (BP measurement approach based on the active control schemes of cuff pressure. Compared with conventional electronic BP instruments, the novelty of the proposed BP measurement approach is to utilize a variable volume chamber which actively and stably alters the cuff pressure during inflating or deflating cycles. The variable volume chamber is operated with a closed-loop pressure control scheme, and it is activated by controlling the piston position of a single-acting cylinder driven by a screw motor. Therefore, the variable volume chamber could significantly eliminate the air turbulence disturbance during the air injection stage when compared to an air pump mechanism. Furthermore, the proposed active BP measurement approach is capable of measuring BP characteristics, including systolic blood pressure (SBP and diastolic blood pressure (DBP, during the inflating cycle. Two modes of air injection measurement (AIM and accurate dual-way measurement (ADM were proposed. According to the healthy subject experiment results, AIM reduced 34.21% and ADM reduced 15.78% of the measurement time when compared to a commercial BP monitor. Furthermore, the ADM performed much consistently (i.e., less standard deviation in the measurements when compared to a commercial BP monitor.

  5. Directly measuring spinal cord blood flow and spinal cord perfusion pressure via the collateral network: correlations with changes in systemic blood pressure.

    Science.gov (United States)

    Kise, Yuya; Kuniyoshi, Yukio; Inafuku, Hitoshi; Nagano, Takaaki; Hirayasu, Tsuneo; Yamashiro, Satoshi

    2015-01-01

    During thoracoabdominal surgery in which segmental arteries are sacrificed over a large area, blood supply routes from collateral networks have received attention as a means of avoiding spinal cord injury. The aim of this study was to investigate spinal cord blood supply through a collateral network by directly measuring spinal cord blood flow and spinal cord perfusion pressure experimentally. In beagle dogs (n = 8), the thoracoabdominal aorta and segmental arteries L1-L7 were exposed, and a temporary bypass was created for distal perfusion. Next, a laser blood flow meter was placed on the spinal dura mater in the L5 region to measure the spinal cord blood flow. The following were measured simultaneously when the direct blood supply from segmental arteries L2-L7 to the spinal cord was stopped: mean systemic blood pressure, spinal cord perfusion pressure (blood pressure within the aortic clamp site), and spinal cord blood flow supplied via the collateral network. These variables were then investigated for evidence of correlations. Positive correlations were observed between mean systemic blood pressure and spinal cord blood flow during interruption of segmental artery flow both with (r = 0.844, P flow with and without distal perfusion (r = 0.803, P network from outside the interrupted segmental arteries, and high systemic blood pressure (∼1.33-fold higher) was needed to obtain the preclamping spinal cord blood flow, whereas 1.68-fold higher systemic blood pressure was needed when distal perfusion was halted. Spinal cord blood flow is positively correlated with mean systemic blood pressure and spinal cord perfusion pressure under spinal cord ischemia caused by clamping a wide range of segmental arteries. In open and endovascular thoracic and thoracoabdominal surgery, elevating mean systemic blood pressure is a simple and effective means of increasing spinal cord blood flow, and measuring spinal cord perfusion pressure seems to be useful for monitoring

  6. Blood pressure measurement of all five fingers by strain gauge plethysmography

    DEFF Research Database (Denmark)

    Hirai, M; Nielsen, S L; Lassen, N A

    1976-01-01

    of the other fingers was measured using a 24-mm-wide cuff. Blood pressure at the proximal phalanx was higher than that at the intermediate phalanx in all fingers except finger V. The difference of blood pressure values corresponded well with circumference of the finger. In 15 normal subjects, blood pressure...... at the proximal phalanx was compared in fingers I, III, IV, and V, using 16, 20, 24 and 24 mm wide cuffs. Finger blood pressure was closest to arm systolic blood pressure when a 24-mm or 27-mm-wide cuff was used in fingers I, III, and IV, and with a 20-mm-wide cuff in finger V. As the standard deviation......The aim of the present paper was to study the methodological problems involved in measuring systolic blood pressure in all five fingers by the strain gauge technique. In 24 normal subjects, blood pressure at the proximal phalanx of finger I and both at the proximal and the intermediate phalanx...

  7. A novel approach to office blood pressure measurement: 30-minute office blood pressure vs daytime ambulatory blood pressure

    NARCIS (Netherlands)

    Wel, M.C. van der; Buunk, I.E.; Weel, C. van; Thien, Th.; Bakx, J.C.

    2011-01-01

    PURPOSE: Current office blood pressure measurement (OBPM) is often not executed according to guidelines and cannot prevent the white-coat effect. Serial, automated, oscillometric OBPM has the potential to overcome both these problems. We therefore developed a 30-minute OBPM method that we compared

  8. Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure

    NARCIS (Netherlands)

    Imholz, B. P.; Settels, J. J.; van der Meiracker, A. H.; Wesseling, K. H.; Wieling, W.

    1990-01-01

    The aim of the study was to evaluate whether invasive blood pressure responses to orthostatic stress can be replaced by non-invasive continuous finger blood pressure responses. DESIGN - Intrabrachial and Finapres blood pressures were simultaneously measured during passive head up tilt and during

  9. [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].

    Science.gov (United States)

    Zhou, Xia; Wu, Wenli; Bao, Shudi

    2015-07-01

    IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.

  10. The position of the arm during blood pressure measurement in sitting position.

    Science.gov (United States)

    Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo

    2006-12-01

    Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.

  11. Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability.

    Science.gov (United States)

    Stergiou, George S; Parati, Gianfranco; Vlachopoulos, Charalambos; Achimastos, Apostolos; Andreadis, Emanouel; Asmar, Roland; Avolio, Alberto; Benetos, Athanase; Bilo, Grzegorz; Boubouchairopoulou, Nadia; Boutouyrie, Pierre; Castiglioni, Paolo; de la Sierra, Alejandro; Dolan, Eamon; Head, Geoffrey; Imai, Yutaka; Kario, Kazuomi; Kollias, Anastasios; Kotsis, Vasilis; Manios, Efstathios; McManus, Richard; Mengden, Thomas; Mihailidou, Anastasia; Myers, Martin; Niiranen, Teemu; Ochoa, Juan Eugenio; Ohkubo, Takayoshi; Omboni, Stefano; Padfield, Paul; Palatini, Paolo; Papaioannou, Theodore; Protogerou, Athanasios; Redon, Josep; Verdecchia, Paolo; Wang, Jiguang; Zanchetti, Alberto; Mancia, Giuseppe; O'Brien, Eoin

    2016-09-01

    Office blood pressure measurement has been the basis for hypertension evaluation for almost a century. However, the evaluation of blood pressure out of the office using ambulatory or self-home monitoring is now strongly recommended for the accurate diagnosis in many, if not all, cases with suspected hypertension. Moreover, there is evidence that the variability of blood pressure might offer prognostic information that is independent of the average blood pressure level. Recently, advancement in technology has provided noninvasive evaluation of central (aortic) blood pressure, which might have attributes that are additive to the conventional brachial blood pressure measurement. This position statement, developed by international experts, deals with key research and practical issues in regard to peripheral blood pressure measurement (office, home, and ambulatory), blood pressure variability, and central blood pressure measurement. The objective is to present current achievements, identify gaps in knowledge and issues concerning clinical application, and present relevant research questions and directions to investigators and manufacturers for future research and development (primary goal).

  12. Blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, Christina H.; Toftegaard, Thomas Skjødeberg

    2013-01-01

    a reliable blood pressure reading. Results: We found that the patients did not adhere to given instructions when performing blood pressure self-measurement in the waiting room. None of the 81 patients adhered to all six inves- tigated recommendations, while around a quarter adhered to five out of six...

  13. Automatic Blood Pressure Measurements During Exercise

    Science.gov (United States)

    Weaver, Charles S.

    1985-01-01

    Microprocessor circuits and a computer algorithm for automatically measuring blood pressure during ambulatory monitoring and exercise stress testing have been under development at SRI International. A system that records ECG, Korotkov sound, and arm cuff pressure for off-line calculation of blood pressure has been delivered to NASA, and an LSLE physiological monitoring system that performs the algorithm calculations in real-time is being constructed. The algorithm measures the time between the R-wave peaks and the corresponding Korotkov sound on-set (RK-interval). Since the curve of RK-interval versus cuff pressure during deflation is predictable and slowly varying, windows can be set around the curve to eliminate false Korotkov sound detections that result from noise. The slope of this curve, which will generally decrease during exercise, is the inverse of the systolic slope of the brachial artery pulse. In measurements taken during treadmill stress testing, the changes in slopes of subjects with coronary artery disease were markedly different from the changes in slopes of healthy subjects. Measurements of slope and O2 consumption were also made before and after ten days of bed rest during NASA/Ames Research Center bed rest studies. Typically, the maximum rate of O2 consumption during the post-bed rest test is less than the maximum rate during the pre-bed rest test. The post-bed rest slope changes differ from the pre-bed rest slope changes, and the differences are highly correlated with the drop in the maximum rate of O2 consumption. We speculate that the differences between pre- and post-bed rest slopes are due to a drop in heart contractility.

  14. Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots.

    Science.gov (United States)

    Acierno, Mark J; da Cunha, Anderson; Smith, Julie; Tully, Thomas N; Guzman, David Sanchez-Migallon; Serra, Verna; Mitchell, Mark A

    2008-11-15

    To determine the level of agreement between direct and indirect blood pressure measurements obtained from healthy Hispaniolan Amazon parrots (Amazona ventralis) anesthetized with isoflurane. Validation study. 16 healthy adult Hispaniolan Amazon parrots. Parrots were anesthetized, and a 26-gauge, 19-mm catheter was placed percutaneously in the superficial ulnar artery for direct measurement of systolic, mean, and diastolic arterial pressures. Indirect blood pressure measurements were obtained with a Doppler ultrasonic flow detector and an oscillometric unit. The Bland-Altman method was used to compare direct and indirect blood pressure values. There was substantial disagreement between direct systolic arterial blood pressure and indirect blood pressure measurements obtained with the Doppler detector from the wing (bias, 24 mm Hg; limits of agreement, -37 to 85 mm Hg) and from the leg (bias, 14 mm Hg; limits of agreement, -14 to 42 mm Hg). Attempts to obtain indirect blood pressure measurements with the oscillometric unit were unsuccessful. Results suggested that there was substantial disagreement between indirect blood pressure measurements obtained with a Doppler ultrasonic flow detector in anesthetized Hispaniolan Amazon parrots and directly measured systolic arterial blood pressure.

  15. Second measurement of morning systolic blood pressure is more closely associated with albuminuria.

    Science.gov (United States)

    Sakabe, Kazumi; Fukui, Michiaki; Ushigome, Emi; Hamaguchi, Masahide; Tanaka, Toru; Atsuta, Haruhiko; Ohnishi, Masayoshi; Oda, Yohei; Hasegawa, Goji; Nakamura, Naoto

    2012-08-01

    It is important to control blood pressure as well as to control blood glucose for the prevention of diabetic nephropathy. However, to our knowledge, there are no reports investigating which blood pressure, including morning, evening and clinic, is more closely associated with albuminuria and whether one measurement is sufficient or not in patients with Type 2 diabetes. We measured morning, evening and clinic blood pressure and compared the area under the curve (AUC) of blood pressure for urinary albumin excretion equal to or more than 30 mg/g creatinine using receiver-operating characteristic curve analyses and odds ratio for albuminuria defined as urinary albumin excretion equal to or more than 30 mg/g creatinine in 858 patients with Type 2 diabetes. Odds ratio (95% confidence interval (CI)) of morning, evening and clinic systolic blood pressure for albuminuria was 1.034 (1.024 - 1.044), 1.033 (1.023 - 1.043) and 1.013 (1.055 - 1.021), respectively (p AUC of morning, evening and clinic systolic blood pressure was 0.644 (0.628 - 0.700) (p AUC of the second morning systolic blood pressure was greater than the first (p = 0.033). The second measurement of morning systolic blood pressure is more closely associated with albuminuria than the first measurement of the morning in addition to clinic systolic blood pressure.

  16. Student measurement of blood pressure using a simulator arm compared with a live subject's arm.

    Science.gov (United States)

    Lee, Jennifer J; Sobieraj, Diana M; Kuti, Effie L

    2010-06-15

    To compare accuracy of blood pressure measurements using a live subject and a simulator arm, and to determine students' preferences regarding measurement. This was a crossover study comparing blood pressure measurements from a live subject and a simulator arm. Students completed an anonymous survey instrument defining opinions on ease of measurement. Fifty-seven students completed blood pressure measurements on live subjects while 72 students completed blood pressure measurements using the simulator arm. There were no significant systematic differences between the 2 measurement techniques. Systolic blood pressure measurements from a live subject arm were less likely to be within 4 mm Hg compared with measurements of a simulator arm. Diastolic blood pressure measurements were not significantly different between the 2 techniques. Accuracy of student measurement of blood pressure using a simulator arm was similar to the accuracy with a live subject. There was no difference in students' preferences regarding measurement techniques.

  17. Polynomial analysis of ambulatory blood pressure measurements

    NARCIS (Netherlands)

    Zwinderman, A. H.; Cleophas, T. A.; Cleophas, T. J.; van der Wall, E. E.

    2001-01-01

    In normotensive subjects blood pressures follow a circadian rhythm. A circadian rhythm in hypertensive patients is less well established, and may be clinically important, particularly with rigorous treatments of daytime blood pressures. Polynomial analysis of ambulatory blood pressure monitoring

  18. Noninvasive blood pressure measurement scheme based on optical fiber sensor

    Science.gov (United States)

    Liu, Xianxuan; Yuan, Xueguang; Zhang, Yangan

    2016-10-01

    Optical fiber sensing has many advantages, such as volume small, light quality, low loss, strong in anti-jamming. Since the invention of the optical fiber sensing technology in 1977, optical fiber sensing technology has been applied in the military, national defense, aerospace, industrial, medical and other fields in recent years, and made a great contribution to parameter measurement in the environment under the limited condition .With the rapid development of computer, network system, the intelligent optical fiber sensing technology, the sensor technology, the combination of computer and communication technology , the detection, diagnosis and analysis can be automatically and efficiently completed. In this work, we proposed a noninvasive blood pressure detection and analysis scheme which uses optical fiber sensor. Optical fiber sensing system mainly includes the light source, optical fiber, optical detector, optical modulator, the signal processing module and so on. wavelength optical signals were led into the optical fiber sensor and the signals reflected by the human body surface were detected. By comparing actual testing data with the data got by traditional way to measure the blood pressure we can establish models for predicting the blood pressure and achieve noninvasive blood pressure measurement by using spectrum analysis technology. Blood pressure measurement method based on optical fiber sensing system is faster and more convenient than traditional way, and it can get accurate analysis results in a shorter period of time than before, so it can efficiently reduce the time cost and manpower cost.

  19. Automated Office Blood Pressure Measurement.

    Science.gov (United States)

    Myers, Martin G

    2018-04-01

    Manual blood pressure (BP) recorded in routine clinical practice is relatively inaccurate and associated with higher readings compared to BP measured in research studies in accordance with standardized measurement guidelines. The increase in routine office BP is the result of several factors, especially the presence of office staff, which tends to make patients nervous and also allows for conversation to occur. With the disappearance of the mercury sphygmomanometer because of environmental concerns, there is greater use of oscillometric BP recorders, both in the office setting and elsewhere. Although oscillometric devices may reduce some aspects of observer BP measurement error in the clinical setting, they are still associated with higher BP readings, known as white coat hypertension (for diagnosis) or white coat effect (with treated hypertension). Now that fully automated sphygmomanometers are available which are capable of recording several readings with the patient resting quietly, there is no longer any need to have office staff present when BP is being recorded. Such readings are called automated office blood pressure (AOBP) and they are both more accurate than conventional manual office BP and not associated with the white coat phenomena. AOBP readings are also similar to the awake ambulatory BP and home BP, both of which are relatively good predictors of cardiovascular risk. The available evidence suggests that AOBP should now replace manual or electronic office BP readings when screening patients for hypertension and also after antihypertensive drug therapy is initiated. Copyright © 2018. The Korean Society of Cardiology.

  20. Nurse-measured or ambulatory blood pressure in routine hypertension care

    NARCIS (Netherlands)

    Veerman, D. P.; van Montfrans, G. A.

    1993-01-01

    Nurses are considered to evoke less white-coat hypertension, and might therefore be able to estimate average blood pressure as well as and more conveniently than ambulatory monitoring. The objective of the present study was to determine the correspondence between blood pressure measured by a doctor

  1. Diurnal blood pressure changes.

    Science.gov (United States)

    Asayama, Kei; Satoh, Michihiro; Kikuya, Masahiro

    2018-05-23

    The definition of diurnal blood pressure changes varies widely, which can be confusing. Short-term blood pressure variability during a 24-h period and the dipping status of diurnal blood pressure can be captured by ambulatory blood pressure monitoring, and these metrics are reported to have prognostic significance for cardiovascular complications. Morning blood pressure surge also indicates this risk, but its effect may be limited to populations with specific conditions. Meanwhile, the combined use of conventional office blood pressure and out-of-office blood pressure allows us to identify people with white-coat and masked hypertension. Current home devices can measure nocturnal blood pressure during sleep more conveniently than ambulatory monitoring; however, we should pay attention to blood pressure measurement conditions regardless of whether they are in a home, ambulatory, or office setting. The relatively poor reproducibility of diurnal blood pressure changes, including the nocturnal fall of blood pressure, is another underestimated issue to be addressed. Although information on diurnal blood pressure changes is expected to be used more effectively in the future, we should also keep in mind that blood pressure levels have remained central to the primary and secondary prevention of blood pressure-related cardiovascular diseases in clinical practice.

  2. The impact of arm position on the measurement of orthostatic blood pressure.

    Science.gov (United States)

    Guss, David A; Abdelnur, Diego; Hemingway, Thomas J

    2008-05-01

    Blood pressure is a standard vital sign in patients evaluated in an Emergency Department. The American Heart Association has recommended a preferred position of the arm and cuff when measuring blood pressure. There is no formal recommendation for arm position when measuring orthostatic blood pressure. The objective of this study was to assess the impact of different arm positions on the measurement of postural changes in blood pressure. This was a prospective, unblinded, convenience study involving Emergency Department patients with complaints unrelated to cardiovascular instability. Repeated blood pressure measurements were obtained using an automatic non-invasive device with each subject in a supine and standing position and with the arm parallel and perpendicular to the torso. Orthostatic hypotension was defined as a difference of >or= 20 mm Hg systolic or >or= 10 mm Hg diastolic when subtracting standing from supine measurements. There were four comparisons made: group W, arm perpendicular supine and standing; group X, arm parallel supine and standing; group Y, arm parallel supine and perpendicular standing; and group Z, arm perpendicular supine and parallel standing. There were 100 patients enrolled, 55 men, mean age 44 years. Four blood pressure measurements were obtained on each patient. The percentage of patients meeting orthostatic hypotension criteria in each group was: W systolic 6% (95% CI 1%, 11%), diastolic 4% (95% CI 0%, 8%), X systolic 8% (95% CI 3%, 13%), diastolic 9% (95% CI 3%, 13%), Y systolic 19% (95% CI 11%, 27%), diastolic 30% (95% CI 21%, 39%), Z systolic 2% (95% CI 0%, 5%), diastolic 2% (95% CI 0%, 5%). Comparison of Group Y vs. X, Z, and W was statistically significant (p postural changes in blood pressure. The combination of the arm parallel when supine and perpendicular when standing may significantly overestimate the orthostatic change. Arm position should be held constant in supine and standing positions when assessing for orthostatic

  3. A novel wearable device for continuous, non-invasion blood pressure measurement.

    Science.gov (United States)

    Xin, Qin; Wu, Jianping

    2017-08-01

    In this paper, we have developed a wearable cuffless device for daily blood pressure (BP) measurement. We incorporated the light based sensor and other hard wares in a small volume for BP detection. With optimized algorithm, the real-time BP reading could be achieved, the data could be presented in the screen and be transmitted by internet of things (IoT) for history data comparison and multi-terminal viewing. Thus, further analysis provides the probability for diet or sports suggestion and alarm. We have measured BP from more than 60 subjects, compare to traditional mercury blood pressure meter, no obvious error in both systolic blood pressure (SBP) and diastolic blood pressure (DBP) are detected. Such device can be used for continues non-invasion BP detection, and further data docking and health analysis could be achieved. Copyright © 2017. Published by Elsevier Ltd.

  4. Prospective blood pressure measurement in renal transplant recipients.

    Science.gov (United States)

    David, V G; Yadav, B; Jeyaseelan, L; Deborah, M N; Jacob, S; Alexander, S; Varughese, S; John, G T

    2014-05-01

    Blood pressure (BP) control at home is difficult when managed only with office blood pressure monitoring (OBPM). In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM) was compared with ambulatory blood pressure monitoring (ABPM) as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2(nd), 4(th), 6(th), and 9(th) months and all the three methods: OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%). Systolic BP (SBP) and diastolic BP (DBP) measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa: 0.88 vs. 89% specificity, Kappa: 0.71). HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa: 0.71 vs. 50% specificity Kappa: 0.54). In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  5. Prospective blood pressure measurement in renal transplant recipients

    Directory of Open Access Journals (Sweden)

    V G David

    2014-01-01

    Full Text Available Blood pressure (BP control at home is difficult when managed only with office blood pressure monitoring (OBPM. In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM was compared with ambulatory blood pressure monitoring (ABPM as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2 nd , 4 th , 6 th , and 9 th months and all the three methods : OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%. Systolic BP (SBP and diastolic BP (DBP measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa : 0.88 vs. 89% specificity, Kappa : 0.71. HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa : 0.71 vs. 50% specificity Kappa : 0.54. In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  6. Reliable blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, C. H.; Rasmussen, Niels H

    2014-01-01

    Background: Patients often fail to adhere to clinical recommendations when using current blood pressure self-measurement (BPSM) methods and equipment. As existing BPSM equipment is not able to detect non-adherent behavior, this could result in misdiagnosis and treatment error. To overcome...... patients scheduled for self-measuring their blood pressure (BP) in the waiting room at an obstetrics department's outpatient clinic to perform an additional BPSM using ValidAid. We then compared the automatically measured and classified values from ValidAid with our manual observations. Results: We found...

  7. The position of the arm during blood pressure measurement in sitting position.

    NARCIS (Netherlands)

    Adiyaman, A.; Verhoeff, R.; Lenders, J.W.M.; Deinum, J.; Thien, Th.

    2006-01-01

    OBJECTIVE: Determining the influence of the position of the arm on blood pressure measurement in the sitting position. METHODS: Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in

  8. Poor Reliability of Wrist Blood Pressure Self-Measurement at Home: A Population-Based Study.

    Science.gov (United States)

    Casiglia, Edoardo; Tikhonoff, Valérie; Albertini, Federica; Palatini, Paolo

    2016-10-01

    The reliability of blood pressure measurement with wrist devices, which has not previously been assessed under real-life circumstances in general population, is dependent on correct positioning of the wrist device at heart level. We determined whether an error was present when blood pressure was self-measured at the wrist in 721 unselected subjects from the general population. After training, blood pressure was measured in the office and self-measured at home with an upper-arm device (the UA-767 Plus) and a wrist device (the UB-542, not provided with a position sensor). The upper-arm-wrist blood pressure difference detected in the office was used as the reference measurement. The discrepancy between office and home differences was the home measurement error. In the office, systolic blood pressure was 2.5% lower at wrist than at arm (P=0.002), whereas at home, systolic and diastolic blood pressures were higher at wrist than at arm (+5.6% and +5.4%, respectively; Pblood pressure values likely because of a poor memory and rendition of the instructions, leading to the wrong position of the wrist. © 2016 American Heart Association, Inc.

  9. Using the area under the curve to reduce measurement error in predicting young adult blood pressure from childhood measures.

    Science.gov (United States)

    Cook, Nancy R; Rosner, Bernard A; Chen, Wei; Srinivasan, Sathanur R; Berenson, Gerald S

    2004-11-30

    Tracking correlations of blood pressure, particularly childhood measures, may be attenuated by within-person variability. Combining multiple measurements can reduce this error substantially. The area under the curve (AUC) computed from longitudinal growth curve models can be used to improve the prediction of young adult blood pressure from childhood measures. Quadratic random-effects models over unequally spaced repeated measures were used to compute the area under the curve separately within the age periods 5-14 and 20-34 years in the Bogalusa Heart Study. This method adjusts for the uneven age distribution and captures the underlying or average blood pressure, leading to improved estimates of correlation and risk prediction. Tracking correlations were computed by race and gender, and were approximately 0.6 for systolic, 0.5-0.6 for K4 diastolic, and 0.4-0.6 for K5 diastolic blood pressure. The AUC can also be used to regress young adult blood pressure on childhood blood pressure and childhood and young adult body mass index (BMI). In these data, while childhood blood pressure and young adult BMI were generally directly predictive of young adult blood pressure, childhood BMI was negatively correlated with young adult blood pressure when childhood blood pressure was in the model. In addition, racial differences in young adult blood pressure were reduced, but not eliminated, after controlling for childhood blood pressure, childhood BMI, and young adult BMI, suggesting that other genetic or lifestyle factors contribute to this difference. 2004 John Wiley & Sons, Ltd.

  10. The effect of hemiplegia on blood pressure measurement in the elderly.

    OpenAIRE

    Dewar, R.; Sykes, D.; Mulkerrin, E.; Nicklason, F.; Thomas, D.; Seymour, R.

    1992-01-01

    The blood pressure in both arms of 103 unselected hemiplegic patients was measured using a random-zero sphygmomanometer. Although for the whole sample the mean blood pressure in the paretic and unaffected arm was similar, a significant difference was found when the patients were subdivided according to the tone of the arm. The blood pressure was higher in paretic arms of patients with a spastic stroke and lower in the affected arm if the tone was flaccid. No other characteristics were associa...

  11. Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences

    NARCIS (Netherlands)

    van der Hoeven, Niels V.; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A.; van den Born, Bert-Jan H.

    2013-01-01

    There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age ( <50 or ≥60 years) and

  12. Agreement of high definition oscillometry with direct arterial blood pressure measurement at different blood pressure ranges in horses under general anaesthesia.

    Science.gov (United States)

    Tünsmeyer, Julia; Hopster, Klaus; Feige, Karsten; Kästner, Sabine Br

    2015-05-01

    To determine the agreement of high definition oscillometry (HDO) with direct arterial blood pressure measurements in normotensive, hypotensive and hypertensive horses during general anaesthesia. Experimental study. Seven healthy warmblood horses, aged 3-11 years, weighing 470-565 kg. Measurements from a HDO device with the cuff placed around the base of the tail were compared with pressures measured invasively from the facial artery. High blood pressures were induced by intravenous (IV) administration of dobutamine (5 μg kg(-1) minute(-1)) over ten minutes followed by norepinephrine (0.1 mg kg(-1) IV) and low pressures by increasing the inspired fraction of isoflurane and administration of nitroglycerine (0.05 mg kg(-1) IV). For analysis three pressure levels were determined: high (MAP>110 mmHg), normal (60 mmHgstandard deviation for SAP, MAP and DAP were 0.1 ± 19.4 mmHg, 0.5 ± 14.0, 4.7 ± 15.6, respectively. At high pressure levels bias and SD were 26.1 ± 37.3 (SAP), 4.2 ± 19.4 (MAP), 1.5 ± 16.8 (DAP) and at low pressures -20.0 ± 20.9 (SAP), -11.4 ± 19.6 (MAP), -4.7 ± 20.1 (DAP), with HDO measurements at a MAP <50 mmHg often failing. Good agreement with invasive arterial blood pressures was obtained with HDO at normotensive levels in horses. At high and low pressure ranges HDO was unreliable. Therefore, if haemodynamic instability is expected, invasive measurement remains preferable. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  13. Comparison of exercise blood pressure measured by technician and an automated system.

    Science.gov (United States)

    Garcia-Gregory, J A; Jackson, A S; Studeville, J; Squires, W G; Owen, C A

    1984-05-01

    We evaluated the automated system Blood Pressure Measuring System (BPMS) developed by NASA on 277 adult males who elected to have a treadmill test as part of their annual physical. The BPMS uses acoustic transduction with a computer-assisted ECG gating to detect nonsynchronous noise. The BPMS readings were compared to pressures simultaneously measured by trained technicians. For all stages of work, BPMS readings were higher for systolic and lower for diastolic than technician readings. At peak stages of work, BPMS systolic pressures were about 20 mmHg higher than technician readings. Within each 3-min workstage, BPMS readings were found to be more inconsistent than technician readings. The standard errors of measurement for BPMS were from two to three times higher than technician values. These data showed automated blood pressure readings were significantly different than technician values and subject to more random fluctuations. These findings demonstrate the need to view exercise blood pressure measured by automated systems with caution.

  14. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    Science.gov (United States)

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  15. Simultaneously Measured Interarm Blood Pressure Difference and Stroke: An Individual Participants Data Meta-Analysis.

    Science.gov (United States)

    Tomiyama, Hirofumi; Ohkuma, Toshiaki; Ninomiya, Toshiharu; Mastumoto, Chisa; Kario, Kazuomi; Hoshide, Satoshi; Kita, Yoshikuni; Inoguchi, Toyoshi; Maeda, Yasutaka; Kohara, Katsuhiko; Tabara, Yasuharu; Nakamura, Motoyuki; Ohkubo, Takayoshi; Watada, Hirotaka; Munakata, Masanori; Ohishi, Mitsuru; Ito, Norihisa; Nakamura, Michinari; Shoji, Tetsuo; Vlachopoulos, Charalambos; Yamashina, Akira

    2018-06-01

    We conducted individual participant data meta-analysis to examine the validity of interarm blood pressure difference in simultaneous measurement as a marker to identify subjects with ankle-brachial pressure index blood pressure difference >5 mm Hg as being associated with a significant odds ratio for the presence of ankle-brachial pressure index blood pressure difference >15 mm Hg was associated with a significant Cox stratified adjusted hazard ratio for subsequent stroke (hazard ratio, 2.42; 95% confidence interval, 1.27-4.60; P blood pressure differences, measured simultaneously in both arms, may be associated with vascular damage in the systemic arterial tree. These differences may be useful for identifying subjects with an ankle-brachial pressure index of blood pressure in both arms at the first visit. © 2018 American Heart Association, Inc.

  16. Observational study comparing non-invasive blood pressure measurement at the arm and ankle during caesarean section.

    Science.gov (United States)

    Drake, M J P; Hill, J S

    2013-05-01

    Upper-arm non-invasive blood pressure measurement during caesarean section can be uncomfortable and unreliable because of movement artefact in the conscious parturient. We aimed to determine whether ankle blood pressure measurement could be used instead in this patient group by comparing concurrent arm and ankle blood pressure measured throughout elective caesarean section under regional anaesthesia in 64 term parturients. Bland-Altman analysis of mean difference (95% limits of agreement [range]) between the ankle and arm was 11.2 (-20.3 to +42.7 [-67 to +102]) mmHg for systolic arterial pressure, -0.5 (-21.0 to +19.9 [-44 to +91]) mmHg for mean arterial pressure and -3.8 (-25.3 to +17.8 [-41 to +94]) mmHg for diastolic arterial pressure. Although ankle blood pressure measurement is well tolerated and allows greater mobility of the arms than measurement from the arm, the degree of discrepancy between the two sites is unacceptable to allow routine use of ankle blood pressure measurement, especially for systolic arterial pressure. However, ankle blood pressure measurement may be a useful alternative in situations where arm blood pressure measurement is difficult or impossible. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  17. Association of adiposity measures with blood lipids and blood pressure in children aged 8-11 years.

    Science.gov (United States)

    Vizcaíno, Vicente Martínez; Aguilar, Fernando Salcedo; Martínez, Montserrat Solera; López, Mairena Sánchez; Gutiérrez, Ricardo Franquelo; Rodríguez-Artalejo, Fernando

    2007-09-01

    To examine the association of body mass index (BMI), triceps skinfold thickness (TST) and percentage body fat (%BF) from bioelectrical impedance analysis (BIA) with blood lipids, systolic blood pressure (SBP) and diastolic blood pressure (DBP) in children. Cross-sectional study was conducted on 1280 schoolchildren aged 8-11 years from the Cuenca province (Spain). Data collection was conducted under standardized conditions, taking several measurements of each variable to enhance accuracy. Analyses were performed using age-adjusted correlation coefficients, and multiple linear regression adjusted for age, BMI, TST and %BF. Correlations between %BF and apolipoprotein (apo) B, total cholesterol, low-density lipoprotein cholesterol (LDL-c), total cholesterol/HDL-c ratio and DBP were higher than those for BMI and TST. In contrast, the correlations between BMI, and apo A-I and SBP were higher than those for %BF and TST. The results were similar across the sexes. The correlations between each of the three measures of body fatness, and blood lipids and blood pressure were highest in children with greatest BMI and %BF. When analyses were adjusted for the three body fatness measures, %BF showed stronger associations than did BMI or TST with blood lipids and blood pressure, with the exception of apo A-I and SBP, which were more closely associated with BMI. %BF from BIA is more strongly associated than either BMI or TST with most of the blood lipid fractions in schoolchildren aged 8-11 years.

  18. Placental weight, birth measurements, and blood pressure at age 8 years.

    OpenAIRE

    Moore, V M; Miller, A G; Boulton, T J; Cockington, R A; Craig, I H; Magarey, A M; Robinson, J S

    1996-01-01

    OBJECTIVE: To examine relationships between blood pressure during childhood and both placental weight and body size at birth, in an Australian population. DESIGN: A follow up study of a birth cohort, undertaken when cohort members were aged 8 years. SETTING: Adelaide, South Australia. SUBJECTS: 830 children born in the Queen Victoria Hospital in Adelaide, South Australia, during 1975-6. MAIN OUTCOME MEASURES: Systolic and diastolic blood pressure measured when the children were aged 8 years. ...

  19. Influence on Calculated Blood Pressure of Measurement Posture for the Development of Wearable Vital Sign Sensors

    Directory of Open Access Journals (Sweden)

    Shouhei Koyama

    2017-01-01

    Full Text Available We studied a wearable blood pressure sensor using a fiber Bragg grating (FBG sensor, which is a highly accurate strain sensor. This sensor is installed at the pulsation point of the human body to measure the pulse wave signal. A calibration curve is built that calculates the blood pressure by multivariate analysis using the pulse wave signal and a reference blood pressure measurement. However, if the measurement height of the FBG sensor is different from the reference measurement height, an error is included in the reference blood pressure. We verified the accuracy of the blood pressure calculation with respect to the measurement height difference and the posture of the subject. As the difference between the measurement height of the FBG sensor and the reference blood pressure measurement increased, the accuracy of the blood pressure calculation decreased. When the measurement height was identical and only posture was changed, good accuracy was achieved. In addition, when calibration curves were built using data measured in multiple postures, the blood pressure of each posture could be calculated from a single calibration curve. This will allow miniaturization of the necessary electronics of the sensor system, which is important for a wearable sensor.

  20. Influence of short-term blood pressure variability on blood pressure determinations

    NARCIS (Netherlands)

    Bos, W. J.; van Goudoever, J.; van Montfrans, G. A.; Wesseling, K. H.

    1992-01-01

    To evaluate the effect of blood pressure variability on Riva Rocci Korotkoff blood pressure determinations, we studied the intra-arterial pressure during Riva Rocci Korotkoff determinations in 25 patients. In 50 measurements with a cuff deflation rate of 2.5 mm Hg/sec, the systolic intra-arterial

  1. Repeated Blood Pressure Measurements in Childhood in Prediction of Hypertension in Adulthood.

    Science.gov (United States)

    Oikonen, Mervi; Nuotio, Joel; Magnussen, Costan G; Viikari, Jorma S A; Taittonen, Leena; Laitinen, Tomi; Hutri-Kähönen, Nina; Jokinen, Eero; Jula, Antti; Cheung, Michael; Sabin, Matthew A; Daniels, Stephen R; Raitakari, Olli T; Juonala, Markus

    2016-01-01

    Hypertension may be predicted from childhood risk factors. Repeated observations of abnormal blood pressure in childhood may enhance prediction of hypertension and subclinical atherosclerosis in adulthood compared with a single observation. Participants (1927, 54% women) from the Cardiovascular Risk in Young Finns Study had systolic and diastolic blood pressure measurements performed when aged 3 to 24 years. Childhood/youth abnormal blood pressure was defined as above 90th or 95th percentile. After a 21- to 31-year follow-up, at the age of 30 to 45 years, hypertension (>140/90 mm Hg or antihypertensive medication) prevalence was found to be 19%. Carotid intima-media thickness was examined, and high-risk intima-media was defined as intima-media thickness >90th percentile or carotid plaques. Prediction of adulthood hypertension and high-risk intima-media was compared between one observation of abnormal blood pressure in childhood/youth and multiple observations by improved Pearson correlation coefficients and area under the receiver operating curve. When compared with a single measurement, 2 childhood/youth observations improved the correlation for adult systolic (r=0.44 versus 0.35, Phypertension in adulthood (0.63 for 2 versus 0.60 for 1 observation, P=0.003). When compared with 2 measurements, third observation did not provide any significant improvement for correlation or prediction (P always >0.05). A higher number of childhood/youth observations of abnormal blood pressure did not enhance prediction of adult high-risk intima-media thickness. Compared with a single measurement, the prediction of adult hypertension was enhanced by 2 observations of abnormal blood pressure in childhood/youth. © 2015 American Heart Association, Inc.

  2. Difference in blood pressure measurements between arms: methodological and clinical implications.

    Science.gov (United States)

    Clark, Christopher E

    2015-01-01

    Differences in blood pressure measurements between arms are commonly encountered in clinical practice. If such differences are not excluded they can delay the diagnosis of hypertension and can lead to poorer control of blood pressure levels. Differences in blood pressure measurements between arms are associated cross sectionally with other signs of vascular disease such as peripheral arterial disease or cerebrovascular disease. Differences are also associated prospectively with increased cardiovascular mortality and morbidity and all cause mortality. Numbers of publications on inter-arm difference are rising year on year, indicating a growing interest in the phenomenon. The prevalence of an inter-arm difference varies widely between reports, and is correlated with the underlying cardiovascular risk of the population studied. Prevalence is also sensitive to the method of measurement used. This review discusses the prevalence of an inter-arm difference in different populations and addresses current best practice for the detection and the measurement of a difference. The evidence for clinical and for vascular associations of an inter-arm difference is presented in considering the emerging role of an inter-arm blood pressure difference as a novel risk factor for increased cardiovascular morbidity and mortality. Competing aetiological explanations for an inter-arm difference are explored, and gaps in our current understanding of this sign, along with areas in need of further research, are considered.

  3. Measurement of digital blood pressure after local cooling

    DEFF Research Database (Denmark)

    Nielsen, S L; Lassen, N A

    1977-01-01

    A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between...... the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women...

  4. Measures of total stress-induced blood pressure responses are associated with vascular damage.

    Science.gov (United States)

    Nazzaro, Pietro; Seccia, Teresa; Vulpis, Vito; Schirosi, Gabriella; Serio, Gabriella; Battista, Loredana; Pirrelli, Anna

    2005-09-01

    The role of cardiovascular reactivity to study hypertension, and the assessment methods, are still controversial. We aimed to verify the association of hypertension and vascular damage with several measures of cardiovascular response. We studied 40 patients with normal-high (132 +/- 1/87 +/- 1 mm Hg) blood pressure (Group 1) and 80 untreated hypertensive subjects. Postischemic forearm vascular resistance (mFVR) served to differentiate hypertensive subjects (142 +/- 2/92 +/- 1 mm Hg v 143 +/- 2/94 +/- 2 mm Hg, P = NS) with a lower (Group 2) and higher (Group 3) hemodynamic index of vascular damage (4.8 +/- .05 v 6.3 +/- .09, P blood pressure, heart rate, forearm blood flow, and vascular resistance. Reactivity measures included: a) change from baseline, b) residualized score, c) cumulative change from baseline and residualized score, and d) total reactivity as area-under-the-curve (AUC), including changes occurring during baseline and recovery phases. The AUC of systolic blood pressure, diastolic blood pressure, and mFVR progressively increased in the groups (P AUC of SBP, DBP, and forearm blood flow and resistance demonstrated the highest (P AUC of SBP (beta = 0.634) and forearm blood flow (beta = -0.337) were predictive (P blood pressure stress response, as AUC, including baseline and recovery phases, was significantly better associated with hypertension and vascular damage than the other reactivity measures studied.

  5. [Measuring the blood pressure in both arms is of little use; longitudinal study into blood pressure differences between both arms and its reproducibility in patients with diabetes mellitus type 2].

    Science.gov (United States)

    Kleefstra, N; Houweling, S T; Meyboom-de Jong, B; Bilo, H J G

    2007-07-07

    To determine the prevalence of inter-arm blood pressure differences > 10 mmHg in patients with diabetes mellitus type 2 (DM2) and to determine whether these differences are consistent over time. Descriptive. In an evaluation study of 169 DM2 patients from 5 general practices in 2003 and 2004, different methods of oscillatory measurement were used to investigate inter-arm blood pressure differences > 10 mmHg systolic or diastolic. These methods were: one measurement in each arm non-simultaneously (method A), one measurement simultaneously (B) and the mean of two simultaneous measurements (C). With method A an inter-arm blood pressure difference was found in 33% of patients. This percentage diminished to 9 with method C. In 44% (n = 7) of the patients in whom method C detected a relevant blood pressure difference, this difference was not found with method A. In 79% of patients the inter-arm blood pressure difference was not reproduced after one year. In daily practice, one non-simultaneous blood pressure measurement in each arm (method A) was of little value for identification of patients with inter-arm blood pressure differences. The reproducibility was poor one year later. Bilateral blood pressure measurement is therefore of little value.

  6. Clinical comparison of automatic, noninvasive measurements of blood pressure in the forearm and upper arm.

    Science.gov (United States)

    Schell, Kathleen; Bradley, Elisabeth; Bucher, Linda; Seckel, Maureen; Lyons, Denise; Wakai, Sandra; Bartell, Deborah; Carson, Elizabeth; Chichester, Melanie; Foraker, Teresa; Simpson, Kathleen

    2005-05-01

    When the upper arm (area from shoulder to elbow) is inaccessible and/or a standard-sized blood pressure cuff does not fit, some healthcare workers use the forearm to measure blood pressure. To compare automatic noninvasive measurements of blood pressure in the upper arm and forearm. A descriptive, correlational comparison study was conducted in the emergency department of a 1071-bed teaching hospital. Subjects were 204 English-speaking patients 6 to 91 years old in medically stable condition who had entered the department on foot or by wheelchair and who had no exclusions to using their left upper extremity. A Welch Allyn Vital Signs 420 series monitor was used to measure blood pressure in the left upper arm and forearm with the subject seated and the upper arm or forearm at heart level. Pearson r correlation coefficients between measurements in the upper arm and forearm were 0.88 for systolic blood pressure and 0.76 for diastolic blood pressure (P upper arm and forearm differed significantly (t = 2.07, P = .04). A Bland-Altman analysis indicated that the distances between the mean values and the limits of agreement for the 2 sites ranged from 15 mm Hg (mean arterial pressure) to 18.4 mm Hg (systolic pressure). Despite strict attention to correct cuff size and placement of the upper arm or forearm at heart level, measurements of blood pressure obtained noninvasively in the arm and forearm of seated patients in stable condition are not interchangeable.

  7. Proportion and characteristics of patients who measure their blood pressure at home: Nationwide survey in Slovenia

    Directory of Open Access Journals (Sweden)

    Petek-Šter Marija

    2009-01-01

    Full Text Available Introduction. Home blood pressure monitoring has several advantages over blood pressure monitoring at a physician's office, and has become a useful instrument in the management of hypertension. Objective. To explore the rate and characteristics of patients who measure their blood pressure at home. Methods. A sample of 2,752 patients with diagnosis of essential arterial hypertension was selected from 12596 consecutive office visitors. Data of 2,639 patients was appropriate for analysis. The data concerning home blood pressure measurement and patients' characteristics were obtained from the patients' case histories. Results 1,835 (69.5% out of 2,639 patients measured their blood pressure at home. 1,284 (70.0% of home blood pressure patients had their own blood pressure measurement device. There were some important differences between these two groups: home blood pressure patients were more frequently male, of younger age, better educated, from urban area, mostly non-smokers, more likely to have diabetes mellitus and ischemic heart disease and had higher number of co-morbidities and were on other drugs beside antihypertensive medication. Using the logistic regression analysis we found that the most powerful predictors of home blood pressure monitoring had higher education level than primary school OR=1.80 (95% CI 1.37-2.37, non-smoking OR=2.16 (95% CI 1.40-3.33 and having a physician in urban area OR=1.32 (95% CI 1.02-1.71. Conclusion. Home blood pressure monitoring is popular in Slovenia. Patients who measured blood pressure at home were different from patients who did not. Younger age, higher education, non-smoking, having a physician in urban area and longer duration of hypertension were predictors of home blood pressure monitoring.

  8. A comparison of blood pressure measurements in newborns.

    LENUS (Irish Health Repository)

    O'Shea, Joyce

    2012-02-01

    Blood pressure monitoring is an essential component of neonatal intensive care. We compared invasive and noninvasive (Dinamap, Marquette, and Dash) recordings in newborns and also noninvasive values obtained from upper and lower limbs. Infants\\' blood pressure was recorded every 6 hours for 72 hours using three noninvasive devices and compared with invasive readings taken simultaneously. Twenty-five babies were enrolled in the study, with birth weights of 560 to 4500 g and gestation 24 + 1 to 40 + 5 weeks. Three hundred thirty-two recordings were obtained. Comparison between invasive and noninvasive readings revealed that all three noninvasive monitors overread mean blood pressure. There was no significant difference between the cuff recordings obtained from the upper or lower limbs. All three noninvasive devices overestimated mean blood pressure values compared with invasive monitoring. Clinicians may be falsely reassured by noninvasive monitoring. Mean blood pressure values obtained from the upper and lower limb are similar.

  9. Differences in blood pressure by measurement technique in neurocritically ill patients: A technological assessment.

    Science.gov (United States)

    Lele, Abhijit V; Wilson, Daren; Chalise, Prabhakar; Nazzaro, Jules; Krishnamoorthy, Vijay; Vavilala, Monica S

    2018-01-01

    Blood pressure data may vary by measurement technique. We performed a technological assessment of differences in blood pressure measurement between non-invasive blood pressure (NIBP) and invasive arterial blood pressure (ABP) in neurocritically ill patients. After IRB approval, a prospective observational study was performed to study differences in systolic blood pressure (SBP), mean arterial pressure (MAP), and cerebral perfusion pressure (CPP) values measured by NIBP arm, ABP at level of the phlebostatic axis (ABP heart) and ABP at level of the external auditory meatus (ABP brain) at 30 and 45-degree head of bed elevation (HOB) using repeated measure analysis of covariance and correlation coefficients. Overall, 168 patients were studied with median age of 57 ± 15 years, were mostly female (57%), with body mass index ≤30 (66%). Twenty-three percent (n = 39) had indwelling intracranial pressure monitors, and 19.7% (n = 33) received vasoactive agents. ABP heart overestimated ABP brain for SBP (11.5 ± 2.7 mmHg, p ABP heart overestimated NIBP arm for SBP (8 ± 1.5 mmHg, p ABP heart overestimates MAP compared to ABP brain and NIBP arm. Using ABP heart data overestimates CPP and may be responsible for not achieving SBP, MAP or CPP targets aimed at the brain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Prevalence of masked uncontrolled hypertension according to the number of office blood pressure measurements.

    Science.gov (United States)

    Vinyoles, E; Camafort, M; Domenech, M; Coca, A; Sobrino, J

    2015-11-01

    The reported prevalence of masked uncontrolled hypertension (MUCH) varies because many studies are not comparable as they use different measurement methodologies. To evaluate the influence of the number of office blood pressure readings on the prevalence of MUCH we conducted a cross-sectional, multicenter study in treated hypertensive patients. We carried out an observational, cross-sectional, multicenter study in 33 Spanish hospital-based hypertension units, involving 35 investigators and 12 Autonomous Communities. Six blood pressure readings and a 24-h ambulatory blood pressure monitoring were performed in treated hypertensive patients. The means of the first 3 readings (P123), the 2nd, 3rd and 4th readings (P234), the 3rd, 4th and 5th readings (P345) and the last 3 readings (P456) were compared with mean 24-h blood pressure. MUCH was defined as office blood pressure <140/90mmHg and 24-h blood pressure ≥130/80mmHg, considering the first 3 readings (MUCH123), the 2nd, 3rd and 4th readings (MUCH234), the 3rd, 4th and 5th readings (MUCH345) and the last 3 readings (MUCH456). We included 498 hypertensive patients. Mean (standard deviation) office blood pressure measurements were: (P123) 141(18)/82(11); (P234) 139(17)/81(11); (P345) 138(17)/81(11) and (P456) 137(16)/80(10) mmHg. Mean 24-h blood pressure was 127(13.8)/75(9.5) mmHg. The correlation coefficients between ambulatory and office systolic/diastolic blood pressure were (P123):0.48/0.50; (P234):0.50/0.52; (P345):0.50/0.54; and (P456):0.50/0.55 (p<0.001, all). The prevalences of MUCH123, MUCH234, MUCH345 and MUCH456 were 14.5%, 18.9%, 19.5% and 21.1%, respectively. The prevalence of MUCH diagnosis depends on the serial office blood pressure readings, being much higher for the last three blood pressure readings. Discarding the first and second office blood pressure measures seems to be the most accurate method for diagnosing MUCH. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Medicina

  11. How important is the recommended slow cuff pressure deflation rate for blood pressure measurement?

    Science.gov (United States)

    Zheng, Dingchang; Amoore, John N; Mieke, Stephan; Murray, Alan

    2011-10-01

    Cuff pressure deflation rate influences blood pressure (BP) measurement. However, there is little quantitative clinical evidence on its effect. Oscillometric pulses recorded from 75 subjects at the recommended deflation rate of 2-3 mmHg per second were analyzed. Some pulses were removed to realize six faster rates (2-7 times faster than the original). Systolic, diastolic, and mean arterial blood pressures (SBP, DBP, MAP) were determined from the original and six reconstructed oscillometric waveforms. Manual measurement was based on the appearance of oscillometric pulse peaks, and automatic measurement on two model envelopes (linear and polynomial) fitted to the sequence of oscillometric pulse amplitudes. The effects of deflation rate on BP determination and within-subject BP variability were analyzed. For SBP and DBP determined from the manual measurement, different deflation rates resulted in significant changes (both p deflation rate effect (all p > 0.3). Faster deflation increased the within-subject BP variability (all p deflation rate, and for the automatic model-based techniques, the deflation rate had little effect.

  12. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    Directory of Open Access Journals (Sweden)

    Daniel D. Reidpath

    2012-06-01

    Full Text Available Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers using mercury sphygmomanometers. Method: Fifty-six adult volunteers participated in the research. Data were collected by five qualified health workers, and six non-health workers. Participants were randomly allocated to have their blood pressure measured on four consecutive occasions by alternating a qualified health worker with a non-health worker. Descriptive statistics and graphs, and mixed effects linear models to account for the repeated measurement were used in the analysis. Results: Blood pressure readings by non-health workers were more reliable than those taken by qualified health workers. There was no significant difference between the readings taken by qualified health workers and those taken by non-health workers for systolic blood pressure. Non-health workers were, on average, 5–7 mmHg lower in their measures of blood pressure than the qualified health workers (95%HPD: −2.9 to −10.0 for diastolic blood pressure. Conclusion: The results provide empirical evidence that supports the practice of non-health workers using electronic devices for BP measurement in community-based research and screening. Non-health workers recorded blood pressures that differed from qualified health workers by no more than 10 mmHg. The approach is promising, but more research is needed to establish the generalisability of the results.

  13. Continuous Blood Pressure Monitoring in Daily Life

    Science.gov (United States)

    Lopez, Guillaume; Shuzo, Masaki; Ushida, Hiroyuki; Hidaka, Keita; Yanagimoto, Shintaro; Imai, Yasushi; Kosaka, Akio; Delaunay, Jean-Jacques; Yamada, Ichiro

    Continuous monitoring of blood pressure in daily life could improve early detection of cardiovascular disorders, as well as promoting healthcare. Conventional ambulatory blood pressure monitoring (ABPM) equipment can measure blood pressure at regular intervals for 24 hours, but is limited by long measuring time, low sampling rate, and constrained measuring posture. In this paper, we demonstrate a new method for continuous real-time measurement of blood pressure during daily activities. Our method is based on blood pressure estimation from pulse wave velocity (PWV) calculation, which formula we improved to take into account changes in the inner diameter of blood vessels. Blood pressure estimation results using our new method showed a greater precision of measured data during exercise, and a better accuracy than the conventional PWV method.

  14. Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm.

    Science.gov (United States)

    Goldstein, Lara Nicole; Wells, Mike; Sliwa, Karen

    2014-07-25

    Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically relevant (i.e. a difference of ≥10 mmHg). This was a prospective cross-sectional study in an urban ED making use of a convenience sample of 201 patients (18 - 50 years of age) who were not in need of emergency medical treatment. BP was measured in the supine position on both arms and ankles with the correct size cuff according to the manufacturer's guidelines. The arm and ankle BP measurements were compared. There was a clinically and statistically significant difference between arm and ankle systolic BP (SBP) and mean arterial pressure (MAP) (-13 mmHg, 95% confidence interval (CI) -28 - 1 mmHg and -5 mmHg, 95% CI -13 - 4 mmHg, respectively), with less difference in diastolic BP (DBP) (2 mmHg, 95% CI -7 - 10 mmHg). Only 37% of SBP measurements and 83% of MAP measurements were within an error range of 10 mmHg, while 95% of DBP measurements agreed within 10 mmHg. While the average differences (or the bias) were generally not large, large variations in individual patients (indicating poor precision) made the prediction of arm BP from ankle measurements unreliable. Ankle BP cannot be used as a substitute for arm BP in the ED.

  15. Recommendations for blood pressure measuring devices for office/clinic use in low resource settings

    NARCIS (Netherlands)

    Parati, G.; Mendis, S.; Abegunde, D.; Asmar, R.; Mieke, S.; Murray, A.; Shengelia, B.; Steenvoorden, G.; Montfrans, G. van; O'Brien, E.

    2005-01-01

    This paper, which summarizes the conclusions of a WHO Expert meeting, is aimed at proposing indications to develop technical specifications for an accurate and affordable blood pressure measuring device for office/ clinic use in low resource settings. Blood pressure measuring devices to be used in

  16. Arterial blood pressure measurement and pulse wave analysis—their role in enhancing cardiovascular assessment

    International Nuclear Information System (INIS)

    Avolio, Alberto P; Butlin, Mark; Walsh, Andrew

    2010-01-01

    The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blood pressure obtained from the brachial cuff. Although the measurement is taken in a peripheral limb, the values are generally assumed to reflect the pressure throughout the arterial tree in large conduit arteries. Since the arterial pressure pulse becomes modified as it travels away from the heart towards the periphery, this is generally true for mean and diastolic pressure, but not for systolic pressure, and so pulse pressure. The relationship between central and peripheral pulse pressure depends on propagation characteristics of arteries. Hence, while the sphygmomanometer gives values of two single points on the pressure wave (systolic and diastolic pressure), there is additional information that can be obtained from the time-varying pulse waveform that enables an improved quantification of the systolic load on the heart and other central organs. This topical review will assess techniques of pressure measurement that relate to the use of the cuff sphygmomanometer and to the non-invasive registration and analysis of the peripheral and central arterial pressure waveform. Improved assessment of cardiovascular function in relation to treatment and management of high blood pressure will result from future developments in the indirect measurement of arterial blood pressure that involve the conventional cuff sphygmomanometer with the addition of information derived from the peripheral arterial pulse. (topical review)

  17. Blood pressure measurements in the ankle are not equivalent to ...

    African Journals Online (AJOL)

    Background. Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. Objective. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically ...

  18. Does a colour-coded blood pressure diary improve blood pressure control for patients in general practice: the CoCo trial.

    Science.gov (United States)

    Steurer-Stey, Claudia; Zoller, Marco; Chmiel Moshinsky, Corinne; Senn, Oliver; Rosemann, Thomas

    2010-04-14

    Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM) has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary.Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries). Randomised controlled study. 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system). EXPECTED RESULTS/CONCLUSION: The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range 140/>90 mmHg, red: blood pressure in danger zone > 180 mmHg/>110 mmHg) lead to better self-monitoring compared with the conventional (non-colour-coded) blood pressure booklet. The colour-coded, visualised information supports improved perception (awareness and interpretation) of blood pressure and triggers correct behaviour, in the means of improved adherence to the recommended treatment as well as better communication between patients and doctors resulting in improved blood pressure control. ClinicalTrials.gov ID NCT01013467.

  19. Does a colour-coded blood pressure diary improve blood pressure control for patients in general practice: The CoCo trial

    Directory of Open Access Journals (Sweden)

    Senn Oliver

    2010-04-01

    Full Text Available Abstract Background Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. Objective Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. Outcome Primary outcome: Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary. Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries. Methods/Design Randomised controlled study. Population: 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system. Expected results/conclusion The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range ≤ 140/≤ 90 mmHg, yellow: blood pressure >140/>90 mmHg, red: blood pressure in danger zone > 180 mmHg/>110 mmHg lead to better self-monitoring compared with the conventional (non-colour-coded blood pressure booklet. The colour-coded, visualised information supports improved perception (awareness and interpretation of blood pressure and triggers correct behaviour, in the means of improved adherence to the recommended treatment as well as better communication between patients and doctors resulting in improved blood pressure control. Trial registration ClinicalTrials.gov ID NCT01013467

  20. Aortic blood pressure measured via EIT: investigation of different measurement settings.

    Science.gov (United States)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Adler, Andy; Grychtol, Bartłomiej; Solà, Josep; Thiran, Jean-Philippe

    2015-06-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.

  1. Aortic blood pressure measured via EIT: investigation of different measurement settings

    International Nuclear Information System (INIS)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Solà, Josep; Adler, Andy; Grychtol, Bartłomiej; Thiran, Jean-Philippe

    2015-01-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss–Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss–Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg. (paper)

  2. Blood pressure documentation in the emergency department

    Science.gov (United States)

    Daniel, Ana Carolina Queiroz Godoy; Machado, Juliana Pereira; Veiga, Eugenia Velludo

    2017-01-01

    ABSTRACT Objective To analyze the frequency of blood pressure documentation performed by nursing professionals in an emergency department. Methods This is a cross-sectional, observational, descriptive, and analytical study, which included medical records of adult patients admitted to the observation ward of an emergency department, between March and May 2014. Data were obtained through a collection instrument divided into three parts: patient identification, triage data, and blood pressure documentation. For statistical analysis, Pearson’s correlation coefficient was used, with a significance level of α<0.05. Results One hundred fifty-seven records and 430 blood pressure measurements were analyzed with an average of three measurements per patient. Of these measures, 46.5% were abnormal. The mean time from admission to documentation of the first blood pressure measurement was 2.5 minutes, with 42 minutes between subsequent measures. There is no correlation between the systolic blood pressure values and the mean time interval between blood pressure documentations: 0.173 (p=0.031). Conclusion The present study found no correlation between frequency of blood pressure documentation and blood pressure values. The frequency of blood pressure documentation increased according to the severity of the patient and decreased during the length of stay in the emergency department. PMID:28444085

  3. Smart blood pressure holter.

    Science.gov (United States)

    İlhan, İlhan

    2018-03-01

    In this study, a wireless blood pressure holter that can be used with smart mobile devices was developed. The developed blood pressure holter consists of two parts, which are a smart mobile device and a cuff. The smart mobile device is used as a recording, control and display device through a developed interface, while the cuff was designed to take measurements from the arm. Resistor-Capacitor (RC) and digital filters were used on the cuff that communicates with the smart mobile device via Bluetooth. The blood pressure was estimated using the Simple Hill Climbing Algorithm (HCA). It is possible to measure instantaneous or programmable blood pressure and heart rate values at certain intervals using this holter. The test was conducted with 30 individuals at different ages with the guidance of a specialist health personnel. The results showed that an accuracy at 93.89% and 91.95% rates could be obtained for systolic and diastolic pressure values, respectively, when compared with those obtained using a traditional sphygmomanometer. The accuracy level for the heart rate was measured as 97.66%. Furthermore, this device was tested day and night in the holter mode in terms of working time, the continuity of the Bluetooth connection and the reliability of the measurement results. The test results were evaluated separately in terms of measurement accuracy, working time, the continuity of the Bluetooth connection and the reliability of the measurement results. The measurement accuracy for systolic, diastolic blood pressure and heart rate values was obtained as 93.89%, 91.95% and 97.66%, respectively. The maximum number of measurements which can be conducted with four 1000 mA alkaline batteries at 20 min intervals was found approximately 79 (little more than 24 h). In addition, it was determined that the continuity of the Bluetooth connection and the reliability of the measurement results were automatically achieved through the features in the interface developed for the

  4. Design of a Continuous Blood Pressure Measurement System Based on Pulse Wave and ECG Signals.

    Science.gov (United States)

    Li, Jian-Qiang; Li, Rui; Chen, Zhuang-Zhuang; Deng, Gen-Qiang; Wang, Huihui; Mavromoustakis, Constandinos X; Song, Houbing; Ming, Zhong

    2018-01-01

    With increasingly fierce competition for jobs, the pressures on people have risen in recent years, leading to lifestyle and diet disorders that result in significantly higher risks of cardiovascular disease. Hypertension is one of the common chronic cardiovascular diseases; however, mainstream blood pressure measurement devices are relatively heavy. When multiple measurements are required, the user experience and the measurement results may be unsatisfactory. In this paper, we describe the design of a signal collection module that collects pulse waves and electrocardiograph (ECG) signals. The collected signals are input into a signal processing module to filter the noise and amplify the useful physiological signals. Then, we use a wavelet transform to eliminate baseline drift noise and detect the feature points of the pulse waves and ECG signals. We propose the concept of detecting the wave shape associated with an instance, an approach that minimizes the impact of atypical pulse waves on blood pressure measurements. Finally, we propose an improved method for measuring blood pressure based on pulse wave velocity that improves the accuracy of blood pressure measurements by 58%. Moreover, the results meet the american medical instrument promotion association standards, which demonstrate the feasibility of our measurement system.

  5. Reproduction of pressure field in ultrasonic-measurement-integrated simulation of blood flow.

    Science.gov (United States)

    Funamoto, Kenichi; Hayase, Toshiyuki

    2013-07-01

    Ultrasonic-measurement-integrated (UMI) simulation of blood flow is used to analyze the velocity and pressure fields by applying feedback signals of artificial body forces based on differences of Doppler velocities between ultrasonic measurement and numerical simulation. Previous studies have revealed that UMI simulation accurately reproduces the velocity field of a target blood flow, but that the reproducibility of the pressure field is not necessarily satisfactory. In the present study, the reproduction of the pressure field by UMI simulation was investigated. The effect of feedback on the pressure field was first examined by theoretical analysis, and a pressure compensation method was devised. When the divergence of the feedback force vector was not zero, it influenced the pressure field in the UMI simulation while improving the computational accuracy of the velocity field. Hence, the correct pressure was estimated by adding pressure compensation to remove the deteriorating effect of the feedback. A numerical experiment was conducted dealing with the reproduction of a synthetic three-dimensional steady flow in a thoracic aneurysm to validate results of the theoretical analysis and the proposed pressure compensation method. The ability of the UMI simulation to reproduce the pressure field deteriorated with a large feedback gain. However, by properly compensating the effects of the feedback signals on the pressure, the error in the pressure field was reduced, exhibiting improvement of the computational accuracy. It is thus concluded that the UMI simulation with pressure compensation allows for the reproduction of both velocity and pressure fields of blood flow. Copyright © 2012 John Wiley & Sons, Ltd.

  6. Promoting sustainability in quality improvement: an evaluation of a web-based continuing education program in blood pressure measurement.

    Science.gov (United States)

    Block, Lauren; Flynn, Sarah J; Cooper, Lisa A; Lentz, Caroline; Hull, Tammie; Dietz, Katherine B; Boonyasai, Romsai T

    2018-01-10

    The accuracy of blood pressure measurement is variable in office-based settings. Even when staff training programs are effective, knowledge and skills decay over time, supporting the need for ongoing staff training. We evaluated whether a web-based continuing education program in blood pressure measurement reinforced knowledge and skills among clinical staff and promoted sustainability of an existing quality improvement program. Medical assistants and nurses at six primary care clinics within a health system enrolled in a 30-min online educational program designed to refresh their knowledge of blood pressure measurement. A 20-question pre- and post-intervention survey addressed learners' knowledge and attitudes. Direct observation of blood pressure measurement technique before and after the intervention was performed. Differences in responses to pre- and post-module knowledge and attitudes questions and in observation data were analyzed using chi-square tests and simple logistic regression. All 88 clinical staff members participated in the program and completed the evaluation survey. Participants answered 80.6% of questions correctly before the module and 93.4% afterwards (p blood pressure measurement were high at baseline and did not improve significantly. Prior to the intervention, staff adhered to 9 of 18 elements of the recommended technique during at least 90% of observations. Following the program, staff was more likely to explain the protocol, provide a rest period, measure an average blood pressure, and record the average blood pressure, but less likely to measure blood pressure with the arm at heart level and use the right arm. We designed, implemented, and evaluated a web-based educational program to improve knowledge, skills, and attitudes in blood pressure measurement and use of an automated device among nurses and medical assistants in ambulatory care. The program reinforced knowledge related to recommended blood pressure measurement technique

  7. Analysis of baseline, average, and longitudinally measured blood pressure data using linear mixed models.

    Science.gov (United States)

    Hossain, Ahmed; Beyene, Joseph

    2014-01-01

    This article compares baseline, average, and longitudinal data analysis methods for identifying genetic variants in genome-wide association study using the Genetic Analysis Workshop 18 data. We apply methods that include (a) linear mixed models with baseline measures, (b) random intercept linear mixed models with mean measures outcome, and (c) random intercept linear mixed models with longitudinal measurements. In the linear mixed models, covariates are included as fixed effects, whereas relatedness among individuals is incorporated as the variance-covariance structure of the random effect for the individuals. The overall strategy of applying linear mixed models decorrelate the data is based on Aulchenko et al.'s GRAMMAR. By analyzing systolic and diastolic blood pressure, which are used separately as outcomes, we compare the 3 methods in identifying a known genetic variant that is associated with blood pressure from chromosome 3 and simulated phenotype data. We also analyze the real phenotype data to illustrate the methods. We conclude that the linear mixed model with longitudinal measurements of diastolic blood pressure is the most accurate at identifying the known single-nucleotide polymorphism among the methods, but linear mixed models with baseline measures perform best with systolic blood pressure as the outcome.

  8. Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Robert Koprowski

    2017-01-01

    Full Text Available Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject’s left hand. Results. The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is 0.69±0.26 (p<0.05. The phase shift calculated for the maximum correlation is equal to 60±40° (p<0.05. When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (p<0.3. Conclusions. Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement. For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases. The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase.

  9. Office blood pressure or ambulatory blood pressure for the prediction of cardiovascular events.

    Science.gov (United States)

    Mortensen, Rikke Nørmark; Gerds, Thomas Alexander; Jeppesen, Jørgen Lykke; Torp-Pedersen, Christian

    2017-11-21

    To determine the added value of (i) 24-h ambulatory blood pressure relative to office blood pressure and (ii) night-time ambulatory blood pressure relative to daytime ambulatory blood pressure for 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events. A total of 7927 participants were included from the International Database on Ambulatory blood pressure monitoring in relation to Cardiovascular Outcomes. We used cause-specific Cox regression to predict 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events. Discrimination of 10-year outcomes was assessed by time-dependent area under the receiver operating characteristic curve (AUC). No differences in predicted risks were observed when comparing office blood pressure and ambulatory blood pressure. The median difference in 10-year risks (1st; 3rd quartile) was -0.01% (-0.3%; 0.1%) for cardiovascular mortality and -0.1% (-1.1%; 0.5%) for cardiovascular events. The difference in AUC (95% confidence interval) was 0.65% (0.22-1.08%) for cardiovascular mortality and 1.33% (0.83-1.84%) for cardiovascular events. Comparing daytime and night-time blood pressure, the median difference in 10-year risks was 0.002% (-0.1%; 0.1%) for cardiovascular mortality and -0.01% (-0.5%; 0.2%) for cardiovascular events. The difference in AUC was 0.10% (-0.08 to 0.29%) for cardiovascular mortality and 0.15% (-0.06 to 0.35%) for cardiovascular events. Ten-year predictions obtained from ambulatory blood pressure are similar to predictions from office blood pressure. Night-time blood pressure does not improve 10-year predictions obtained from daytime measurements. For an otherwise healthy population sufficient prognostic accuracy of cardiovascular risks can be achieved with office blood pressure. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  10. Student Nurses' Knowledge in Relation to Blood Pressure Measurement by Sphygmomanometry and Auscultation.

    Science.gov (United States)

    Torrance, Colin; Serginson, Eve

    1996-01-01

    British nursing students (78 of 93) completed a questionnaire about blood pressure; 90% were not familiar with Korotkoff sounds or auscultary gap; most thought blood pressure was the same in both arms; 63% knew resting was essential before measurement; 59% assessed the arm for cuff size; only 25% thought the cuff should be placed at heart level.…

  11. ORANGE JUICE AND BLOOD PRESSURE

    Directory of Open Access Journals (Sweden)

    M. F. VALIM

    2009-01-01

    Full Text Available

    Blood pressure is the force of blood against artery walls. It is measured in millimeters of mercury (mm Hg and recorded as two numbers: systolic pressure (as the heart contracts over diastolic pressure (as the heart relaxes between beats. High blood pressure (hypertension is defined as chronically elevated high blood pressure, with systolic blood pressure (SBP of 140 mm Hg or greater, and diastolic blood pressure (DBP of 90 mm Hg or greater. High blood pressure (HBP, smoking, abnormal blood lipid levels, obesity and diabetes are risk factors for coronary heart disease, the leading cause of death in the US. Lifestyle modifications such as engaging in regular physical activity, quitting smoking and eating a healthy diet (limiting intake of saturated fat and sodium and increasing consumption of fiber, fruits and vegetables are advocated for the prevention, treatment, and control of HBP. As multiple factors influence blood pressure, the effects of each factor are typically modest, particularly in normotensive subjects, yet the combined effects can be substantial. Nutrition plays an important role in influencing blood pressure. Orange juice should be included as part of any low sodium diet and/or any blood pressure reducing eating plan, as it is sodium free, fat-free and can help meet recommended levels of potassium intake that may contribute to lower BP.

  12. Hybrid Optical Unobtrusive Blood Pressure Measurements

    Directory of Open Access Journals (Sweden)

    Guangfei Zhang

    2017-07-01

    Full Text Available Blood pressure (BP is critical in diagnosing certain cardiovascular diseases such as hypertension. Some previous studies have proved that BP can be estimated by pulse transit time (PTT calculated by a pair of photoplethysmography (PPG signals at two body sites. Currently, contact PPG (cPPG and imaging PPG (iPPG are two feasible ways to obtain PPG signals. In this study, we proposed a hybrid system (called the ICPPG system employing both methods that can be implemented on a wearable device, facilitating the measurement of BP in an inconspicuous way. The feasibility of the ICPPG system was validated on a dataset with 29 subjects. It has been proved that the ICPPG system is able to estimate PTT values. Moreover, the PTT measured by the new system shows a correlation on average with BP variations for most subjects, which could facilitate a new generation of BP measurement using wearable and mobile devices.

  13. Beat-to-Beat Blood Pressure Monitor

    Science.gov (United States)

    Lee, Yong Jin

    2012-01-01

    This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

  14. Sodium-blood pressure interrelationship in pregnancy.

    Science.gov (United States)

    Franx, A; Steegers, E A; de Boo, T; Thien, T; Merkus, J M

    1999-03-01

    In non-pregnant individuals, a strong positive association of sodium intake with blood pressure has been established, but the relationship between sodium intake and blood pressure in human pregnancy remains obscure up to date. The aim of this prospective observational cohort study was to assess the relationship between urinary sodium excretion (as a measure for intake) and blood pressure from the early second trimester onwards throughout pregnancy. The study group consisted of 667 low-risk women with singleton pregnancies, of whom 350 were nulliparous and 317 parous. Blood pressure was measured in a standardised fashion at predetermined intervals from the first antenatal visit prior to 16 weeks gestation until delivery. Urinary sodium excretion was measured in 24-h urine collections on at least four occasions between 16 and 38 weeks gestation. Main outcome measures were the coefficients of correlation between changes in urinary sodium output and changes in blood pressure during six different gestational epochs. No significant correlations were found between changes in urinary sodium output and changes in blood pressure. Correlation coefficients were alike for nulliparous and parous women and for different gestational intervals. Prior to 32 weeks gestation, no differences were observed in sodium excretion between women who remained normotensive and those who developed gestational hypertension. These results suggest that changes in sodium intake are not associated with blood pressure changes in low-risk pregnant women. Blood pressure increases as observed in the second half of normotensive and hypertensive pregnancies are unlikely to be caused by changes in renal sodium handling.

  15. In the aftermath of SPRINT: further comparison of unattended automated office blood pressure measurement and 24-hour blood pressure monitoring.

    Science.gov (United States)

    Seidlerová, Jitka; Gelžinský, Julius; Mateřánková, Markéta; Ceral, Jiří; König, Petr; Filipovský, Jan

    2018-03-22

    Several papers reported that unattended automated office blood pressure (uAutoOBP) is closely related to daytime ambulatory blood pressure monitoring (ABPM). In the present study, we aim to study uAutoOBP and its relation to 24-hour ABPM and ABPM variability. Stable treated hypertensive subjects were examined in two Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP three times with auscultatory method (AuscOBP) by the physician. ABPM was performed within one week from the clinical visit. Data on 98 subjects aged 67.7 ± 9.3 years with 24-hour ABPM 120.3 ± 10.6/72.7 ± 7.9 mm Hg are reported. uAutoOBP was lower than 24-hour (by -5.2 ± 11.3/-0.5 ± 6.9 mm Hg) and daytime (by -6.7 ± 12.82.4 ± 8.0 mm Hg) ABPM and the individual variability of the difference was very large (up to 30 mm Hg). The correlation coefficients between ABPM and uAutoOBP were similar compared to AuscOBP (p ≥ .17). Variability of uAutoOBP, but not AuscOBP, readings during one clinical visit was related to short-term blood pressure variability of ABPM. The difference between AuscOBP and uAutoOBP was larger in patients with white-coat effect compared to other blood pressure control groups (25.1 ± 7.0 vs. 2.2 ± 10.3 mm Hg; p = .0036). Our study shows that uAutoOBP is not good predictor of ambulatory blood pressure monitoring, not even of the daytime values. It might, however, indicate short-term blood pressure variability and, when compared with AuscOBP, also detect patients with white-coat effect.

  16. Relevance to Home Blood Pressure Monitoring Protocol of Blood Pressure Measurements Taken Before First- Morning Micturition and in the Afternoon

    Directory of Open Access Journals (Sweden)

    Antonio Eduardo Monteiro de Almeida

    2014-10-01

    Full Text Available Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM. Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM as gold-standard and measurements taken before morning micturition (BM and in the afternoon (AM, for the best diagnosis of systemic arterial hypertension (SAH, and their association with prognostic markers. Methods: After undergoing 24-hour wakefulness ABPM, 158 participants (84 women were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM; and with post-morning-micturition and evening measurements (PM+EM. All patients underwent echocardiography (for left ventricular hypertrophy - LVH and urinary albumin measurement (for microalbuminuria - MAU. Result: Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM and (PM+EM, and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM versus (PM+EM were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM and (PM+EM were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions: The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers.

  17. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    OpenAIRE

    Daniel D. Reidpath; Mei Lee Ling; Shajahan Yasin; Kanason Rajagobal; Pascale Allotey

    2012-01-01

    Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers usin...

  18. Out-of-office blood pressure: from measurement to control

    Directory of Open Access Journals (Sweden)

    Baguet JP

    2012-05-01

    Full Text Available Jean-Philippe Baguet1,21Department of Cardiology, University Hospital, 2Bioclinic Radiopharmaceutics Laboratory, INSERM U1039, Joseph Fourier University, Grenoble, FranceAbstract: Hypertension is an important risk factor for the development of cardiovascular disease, and is a major cause of morbidity and mortality worldwide. Traditionally, hypertension diagnosis and treatment and clinical evaluations of antihypertensive efficacy have been based on office blood pressure (BP measurements; however, there is increasing evidence that office measures may provide inadequate or misleading estimates of a patient’s true BP status and level of cardiovascular risk. The introduction, and endorsement by treatment guidelines, of 24-hour ambulatory BP monitoring and self (or home BP monitoring has facilitated more reliable and reproducible estimations of true BP, including the identification of white-coat and masked hypertension, and evaluation of BP variability. In addition, ambulatory BP monitoring enables accurate assessment of treatment effectiveness over 24 hours and both ambulatory and self BP monitoring may lead to better tailoring of therapy according to BP profile and concomitant disease. This review describes the clinical benefits and limitations of out-of-office assessments and their applications for effective management of hypertension and attainment of BP control.Keywords: ambulatory, ABPM, SBPM, blood pressure measurement, hypertension

  19. Inter-arm blood pressure differences in pregnant women.

    Science.gov (United States)

    Poon, L C Y; Kametas, N; Strobl, I; Pachoumi, C; Nicolaides, K H

    2008-08-01

    To determine the prevalence of blood pressure inter-arm difference (IAD) in early pregnancy and to investigate its possible association with maternal characteristics. A cross-sectional observational study. Routine antenatal visit in a university hospital. A total of 5435 pregnant women at 11-14 weeks of gestation. Blood pressure was taken from both arms simultaneously with a validated automated device. The presence of inter-arm blood pressure difference of 10 mmHg or more. The IAD in systolic and diastolic blood pressure was 10 mmHg or more in 8.3 and 2.3% of the women, respectively. Systolic IAD was found to be significantly related to systolic blood pressure and pulse pressure, and diastolic IAD was found to be significantly related to maternal age, diastolic blood pressure and pulse pressure. The systolic and diastolic IAD were higher in the hypertensive group compared with the normotensive group and absolute IAD increased with increasing blood pressure. About 31.0 and 23.9% of cases of hypertension would have been underreported if the left arm and the right arm were used, respectively, in measuring the blood pressure. There is a blood pressure IAD in a significant proportion of the pregnant population, and its prevalence increases with increasing blood pressure. By measuring blood pressure only on one arm, there is a one in three chance of underreporting hypertension. Therefore, it would be prudent that during the booking visit blood pressure should be taken in both arms and thus provide guidance for subsequent blood pressure measurements during the course of pregnancy.

  20. A Comparison and Calibration of a Wrist-Worn Blood Pressure Monitor for Patient Management: Assessing the Reliability of Innovative Blood Pressure Devices

    Science.gov (United States)

    Melville, Sarah; Teskey, Robert; Philip, Shona; Simpson, Jeremy A; Lutchmedial, Sohrab

    2018-01-01

    Background Clinical guidelines recommend monitoring of blood pressure at home using an automatic blood pressure device for the management of hypertension. Devices are not often calibrated against direct blood pressure measures, leaving health care providers and patients with less reliable information than is possible with current technology. Rigorous assessments of medical devices are necessary for establishing clinical utility. Objective The purpose of our study was 2-fold: (1) to assess the validity and perform iterative calibration of indirect blood pressure measurements by a noninvasive wrist cuff blood pressure device in direct comparison with simultaneously recorded peripheral and central intra-arterial blood pressure measurements and (2) to assess the validity of the measurements thereafter of the noninvasive wrist cuff blood pressure device in comparison with measurements by a noninvasive upper arm blood pressure device to the Canadian hypertension guidelines. Methods The cloud-based blood pressure algorithms for an oscillometric wrist cuff device were iteratively calibrated to direct pressure measures in 20 consented patient participants. We then assessed measurement validity of the device, using Bland-Altman analysis during routine cardiovascular catheterization. Results The precalibrated absolute mean difference between direct intra-arterial to wrist cuff pressure measurements were 10.8 (SD 9.7) for systolic and 16.1 (SD 6.3) for diastolic. The postcalibrated absolute mean difference was 7.2 (SD 5.1) for systolic and 4.3 (SD 3.3) for diastolic pressures. This is an improvement in accuracy of 33% systolic and 73% diastolic with a 48% reduction in the variability for both measures. Furthermore, the wrist cuff device demonstrated similar sensitivity in measuring high blood pressure compared with the direct intra-arterial method. The device, when calibrated to direct aortic pressures, demonstrated the potential to reduce a treatment gap in high blood

  1. Blood Pressure Test

    Science.gov (United States)

    ... pressure monitors may have some limitations. Tracking your blood pressure readings It can be helpful in diagnosing or ... more Stage 2 high blood pressure (hypertension) Elevated blood pressure and stages 1 and 2 high blood pressure ( ...

  2. Should blood pressure be measured with the cuff on a bare arm?

    NARCIS (Netherlands)

    Thien, T.; Keltjens, E.B.; Lenders, J.W.M.; Deinum, J.

    2015-01-01

    OBJECTIVE: To establish whether the results of blood pressure (BP) measurements are affected by wearing clothing underneath the BP cuff during measurement. METHODS: Normotensive and hypertensive patients (n=133; 65 men) of an outpatient clinic participated in this study. BP was measured according to

  3. Ambulatory blood pressure monitoring-derived short-term blood pressure variability in primary hyperparathyroidism.

    Science.gov (United States)

    Concistrè, A; Grillo, A; La Torre, G; Carretta, R; Fabris, B; Petramala, L; Marinelli, C; Rebellato, A; Fallo, F; Letizia, C

    2018-04-01

    Primary hyperparathyroidism is associated with a cluster of cardiovascular manifestations, including hypertension, leading to increased cardiovascular risk. The aim of our study was to investigate the ambulatory blood pressure monitoring-derived short-term blood pressure variability in patients with primary hyperparathyroidism, in comparison with patients with essential hypertension and normotensive controls. Twenty-five patients with primary hyperparathyroidism (7 normotensive,18 hypertensive) underwent ambulatory blood pressure monitoring at diagnosis, and fifteen out of them were re-evaluated after parathyroidectomy. Short-term-blood pressure variability was derived from ambulatory blood pressure monitoring and calculated as the following: 1) Standard Deviation of 24-h, day-time and night-time-BP; 2) the average of day-time and night-time-Standard Deviation, weighted for the duration of the day and night periods (24-h "weighted" Standard Deviation of BP); 3) average real variability, i.e., the average of the absolute differences between all consecutive BP measurements. Baseline data of normotensive and essential hypertension patients were matched for age, sex, BMI and 24-h ambulatory blood pressure monitoring values with normotensive and hypertensive-primary hyperparathyroidism patients, respectively. Normotensive-primary hyperparathyroidism patients showed a 24-h weighted Standard Deviation (P blood pressure higher than that of 12 normotensive controls. 24-h average real variability of systolic BP, as well as serum calcium and parathyroid hormone levels, were reduced in operated patients (P blood pressure variability is increased in normotensive patients with primary hyperparathyroidism and is reduced by parathyroidectomy, and may potentially represent an additional cardiovascular risk factor in this disease.

  4. Reliability of blood pressure measurement and cardiovascular risk prediction

    NARCIS (Netherlands)

    van der Hoeven, N.V.

    2016-01-01

    High blood pressure is one of the leading risk factors for cardiovascular disease, but difficult to reliably assess because there are many factors which can influence blood pressure including stress, exercise or illness. The first part of this thesis focuses on possible ways to improve the

  5. Differences in blood pressure measurements in the forearm and upper arm of obese otherwise healthy first year medical students

    Directory of Open Access Journals (Sweden)

    Suganthi V, Navin Rajaratnam, Suzanne Maria D’cruz

    2014-07-01

    Full Text Available Background: The prevalence of obesity is increasing in Indian youth and obesity is associated with complications like systemic hypertension. Often, due to the non-availability of appropriate sized cuffs, standard cuff bladders are used to measure blood pressure in the forearms of obese young adults. Aim: To compare the upper arm arterial blood pressure measured using an appropriate cuff with the forearm arterial blood pressure measured using a standard cuff and conventional sphygmomanometry in obese otherwise healthy first year medical students. Materials and Methods: Blood pressure was measured in 27 obese otherwise healthy first year medical students after five minutes of rest using a mercury sphygmomanometer with the subjects seated and the arm and forearm at heart level, using an appropriate sized cuff for the upper arm according to American Heart Association standards and a standard cuff for the fore arm. Results: A statistically significant difference in both systolic [t-test (paired = -6.921; df = 26; sig = .000 (2- tailed] and diastolic blood pressure [t-test (paired = -8.508; df = 26; sig = .000 (2- tailed] was found, with the blood pressure readings being higher in the forearm. The correlations between upper arm and forearm systolic and diastolic blood pressure were 0.785 (p = .000 and 0.870 (p = .000. Conclusion: Both systolic and diastolic blood pressure measurements were significantly higher in the forearm. Further studies with larger sample size should be conducted to confirm that forearm blood pressure measurements using standard cuff bladders cannot be considered equal to upper arm measurements made using an appropriate sized cuff in all young obese individuals

  6. Definition of ambulatory blood pressure targets for diagnosis and treatment of hypertension in relation to clinic blood pressure: prospective cohort study.

    Science.gov (United States)

    Head, Geoffrey A; Mihailidou, Anastasia S; Duggan, Karen A; Beilin, Lawrence J; Berry, Narelle; Brown, Mark A; Bune, Alex J; Cowley, Diane; Chalmers, John P; Howe, Peter R C; Hodgson, Jonathan; Ludbrook, John; Mangoni, Arduino A; McGrath, Barry P; Nelson, Mark R; Sharman, James E; Stowasser, Michael

    2010-04-14

    Twenty-four hour ambulatory blood pressure thresholds have been defined for the diagnosis of mild hypertension but not for its treatment or for other blood pressure thresholds used in the diagnosis of moderate to severe hypertension. We aimed to derive age and sex related ambulatory blood pressure equivalents to clinic blood pressure thresholds for diagnosis and treatment of hypertension. We collated 24 hour ambulatory blood pressure data, recorded with validated devices, from 11 centres across six Australian states (n=8575). We used least product regression to assess the relation between these measurements and clinic blood pressure measured by trained staff and in a smaller cohort by doctors (n=1693). Mean age of participants was 56 years (SD 15) with mean body mass index 28.9 (5.5) and mean clinic systolic/diastolic blood pressure 142/82 mm Hg (19/12); 4626 (54%) were women. Average clinic measurements by trained staff were 6/3 mm Hg higher than daytime ambulatory blood pressure and 10/5 mm Hg higher than 24 hour blood pressure, but 9/7 mm Hg lower than clinic values measured by doctors. Daytime ambulatory equivalents derived from trained staff clinic measurements were 4/3 mm Hg less than the 140/90 mm Hg clinic threshold (lower limit of grade 1 hypertension), 2/2 mm Hg less than the 130/80 mm Hg threshold (target upper limit for patients with associated conditions), and 1/1 mm Hg less than the 125/75 mm Hg threshold. Equivalents were 1/2 mm Hg lower for women and 3/1 mm Hg lower in older people compared with the combined group. Our study provides daytime ambulatory blood pressure thresholds that are slightly lower than equivalent clinic values. Clinic blood pressure measurements taken by doctors were considerably higher than those taken by trained staff and therefore gave inappropriate estimates of ambulatory thresholds. These results provide a framework for the diagnosis and management of hypertension using ambulatory blood pressure values.

  7. Development of a wireless blood pressure measuring device with smart mobile device.

    Science.gov (United States)

    İlhan, İlhan; Yıldız, İbrahim; Kayrak, Mehmet

    2016-03-01

    Today, smart mobile devices (telephones and tablets) are very commonly used due to their powerful hardware and useful features. According to an eMarketer report, in 2014 there were 1.76 billion smartphone users (excluding users of tablets) in the world; it is predicted that this number will rise by 15.9% to 2.04 billion in 2015. It is thought that these devices can be used successfully in biomedical applications. A wireless blood pressure measuring device used together with a smart mobile device was developed in this study. By means of an interface developed for smart mobile devices with Android and iOS operating systems, a smart mobile device was used both as an indicator and as a control device. The cuff communicating with this device through Bluetooth was designed to measure blood pressure via the arm. A digital filter was used on the cuff instead of the traditional analog signal processing and filtering circuit. The newly developed blood pressure measuring device was tested on 18 patients and 20 healthy individuals of different ages under a physician's supervision. When the test results were compared with the measurements made using a sphygmomanometer, it was shown that an average 93.52% accuracy in sick individuals and 94.53% accuracy in healthy individuals could be achieved with the new device. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Low Blood Pressure

    Science.gov (United States)

    ... a problem. Sometimes blood pressure that is too low can also cause problems. Blood pressure is the ... reading is 90/60 or lower, you have low blood pressure. Some people have low blood pressure ...

  9. Use of ambulatory blood pressure measurement in the definition of resistant hypertension: a review of the evidence.

    Science.gov (United States)

    Persu, Alexandre; O'Brien, Eoin; Verdecchia, Paolo

    2014-11-01

    Resistant hypertension as defined by the European Society of Hypertension and American Heart Association is a blood pressure that remains uncontrolled despite concomitant intake of at least three antihypertensive drugs (one of them preferably being a diuretic) at full doses. This definition is still based on office rather than out-of-office blood pressure measurement. In this review we propose a new, stricter definition of resistant hypertension based on ambulatory blood pressure measurement. The main arguments in favor of this are: (1) in patients with resistant hypertension, ambulatory blood pressure is an independent predictor of cardiovascular morbidity whereas, after adjustment for conventional risk factors, conventional blood pressure has little added value; (2) white-coat resistant hypertension (uncontrolled office with normal ambulatory blood pressure) is frequent (30-40% of patients with apparently resistant hypertension) carrying a prognosis similar to that of controlled hypertension, and intensification of blood pressure lowering treatment, or the use of nondrug treatment strategies such as renal denervation or carotid baroreceptor stimulation, is not justified; (3) masked resistant hypertension (controlled office with elevated ambulatory blood pressure) is frequent (approximately one-third of patients with controlled office blood pressure on triple antihypertensive therapy) and associated with an increased risk of cardiovascular events; in such patients, treatment intensification should be considered; (4) the current definition of resistant hypertension (office blood pressure ⩾ 140/90 mm Hg on triple antihypertensive therapy) allows a substantial proportion of patients with spurious or white-coat resistant hypertension to undergo renal denervation in the absence of proven long-term benefits.

  10. The feasibility and reliability of capillary blood pressure measurements in the fingernail fold

    NARCIS (Netherlands)

    de Graaff, Jurgen C.; Ubbink, Dirk Th; Lagarde, Sjoerd M.; Jacobs, Michael J. H. M.

    2002-01-01

    Capillary blood pressure is an essential parameter in the study of the (patho-)physiology of microvascular perfusion. Currently, capillary pressure measurements in humans are performed using a servo-nulling micropressure system containing an oil-water interface, which suffers some drawbacks. In

  11. Healing of ulcers on the feet correlated with distal blood pressure measurements in occlusive arterial disease

    DEFF Research Database (Denmark)

    Holstein, P; Lassen, N A

    1980-01-01

    The frequency of healing in subchronic ulcers in 66 feet in 62 patients with arterial occlusive disease was correlated with the systolic digital blood pressure (SDBP) and the systolic ankle blood pressure (SABP), both measured with a strain gauge, and with the skin perfusion pressure on the heel...

  12. Contributions of mean and shape of blood pressure distribution to worldwide trends and variations in raised blood pressure

    DEFF Research Database (Denmark)

    Overvad, Kim

    2018-01-01

    interventions to control blood pressure in the hypertensive population). Our aim was to quantify the contributions of these two phenomena to the worldwide trends in the prevalence of raised blood pressure. Methods: We pooled 1018 population-based studies with blood pressure measurements on 88.6 million......, where relevant. We used a linear mixed effect model to quantify the association between (probit-transformed) prevalence of raised blood pressure and age-group- and sex-specific mean blood pressure. We calculated the contributions of change in mean SBP and DBP, and of change in the prevalence...... participants from 1985 to 2016. We first calculated mean systolic blood pressure (SBP), mean diastolic blood pressure (DBP) and prevalence of raised blood pressure by sex and 10-year age group from 20-29 years to 70-79 years in each study, taking into account complex survey design and survey sample weights...

  13. Hybrid optical unobtrusive blood pressure measurements

    NARCIS (Netherlands)

    Zhang, G.; Shan, C.; Kirenko, I.; Long, X.; Aarts, R.M.

    2017-01-01

    Blood pressure (BP) is critical in diagnosing certain cardiovascular diseases such as hypertension. Some previous studies have proved that BP can be estimated by pulse transit time (PTT) calculated by a pair of photoplethysmography (PPG) signals at two body sites. Currently, contact PPG (cPPG) and

  14. Sleep deprivation increases blood pressure in healthy normotensive elderly and attenuates the blood pressure response to orthostatic challenge.

    Science.gov (United States)

    Robillard, Rébecca; Lanfranchi, Paola A; Prince, François; Filipini, Daniel; Carrier, Julie

    2011-03-01

    To determine how aging affects the impact of sleep deprivation on blood pressure at rest and under orthostatic challenge. Subjects underwent a night of sleep and 24.5 h of sleep deprivation in a crossover counterbalanced design. Sleep laboratory. Sixteen healthy normotensive men and women: 8 young adults (mean 24 years [SD 3.1], range 20-28 years) and 8 elderly adults (mean 64.1 years [SD 3.4], range 60-69 years). Sleep deprivation. Brachial cuff arterial blood pressure and heart rate were measured in semi-recumbent and upright positions. These measurements were compared across homeostatic sleep pressure conditions and age groups. Sleep deprivation induced a significant increase in systolic and diastolic blood pressure in elderly but not young adults. Moreover, sleep deprivation attenuated the systolic blood pressure orthostatic response in both age groups. Our results suggest that sleep deprivation alters the regulatory mechanisms of blood pressure and might increase the risk of hypertension in healthy normotensive elderly.

  15. DETERMINANTS OF SUBOPTIMAL BLOOD PRESSURE CONTROL IN HYPERTENSIVE PATIENTS: 24-HOUR AMBULATORY BLOOD PRES-SURE MONITORING

    Directory of Open Access Journals (Sweden)

    Mansoor Moazenzadeh

    2010-12-01

    Full Text Available Abstract    INTRODUCTION: The study was conducted to define the determinants of suboptimal blood pressure (BP control among hypertensive patients under treatment and explore a predictive model for detecting the patients at risk for increased BP.    METHODS: We enrolled 97 patients (40 males, 57 females under treatment for hypertension between June 2006 and May 2007 in Shafa hospital, Kerman, Iran. BP was measured at clinic twice within 5-minute intervals. After setting up ambulatory blood pressure monitoring (ABPM, BP was measured at 30-minute intervals during the day and 60-minute intervals during the night. The frequency of increased BP (more than 140/90 mmHg was included in a regression model as dependent variable and all the others such as age, sex, body mass index (BMI, drugs and baseline clinical measurements as the predictors.    RESULTS: Increased BP was detected in 44% (95% CI: 38.79%-49.65% of all measurements during 24-hour monitoring. The frequency of increased BP had a significant relationship with BMI (b=0.35, P=0.001. Clinic's pulse pressure was a significant predicting factor for BP increase (P=0.02.    CONCLUSION: BMI and pulse pressure are the best predictors for being hypertensive during lifetime. Ineffective treatment of hypertension is frequent among the hypertensive patients.      Keywords: Blood pressure control, Pulse pressure, Ambulatory blood pressure monitoring (ABPM, BMI.

  16. Attended and Unattended Automated Office Blood Pressure Measurements Have Better Agreement With Ambulatory Monitoring Than Conventional Office Readings.

    Science.gov (United States)

    Andreadis, Emmanuel A; Geladari, Charalampia V; Angelopoulos, Epameinondas T; Savva, Florentia S; Georgantoni, Anna I; Papademetriou, Vasilios

    2018-04-07

    Automated office blood pressure (AOBP) measurement is superior to conventional office blood pressure (OBP) because it eliminates the "white coat effect" and shows a strong association with ambulatory blood pressure. We conducted a cross-sectional study in 146 participants with office hypertension, and we compared AOBP readings, taken with or without the presence of study personnel, before and after the conventional office readings to determine whether their variation in blood pressure showed a difference in blood pressure values. We also compared AOBP measurements with daytime ambulatory blood pressure monitoring and conventional office readings. The mean age of the studied population was 56±12 years, and 53.4% of participants were male. Bland-Altman analysis revealed a bias (ie, mean of the differences) of 0.6±6 mm Hg systolic for attended AOBP compared with unattended and 1.4±6 and 0.1±6 mm Hg bias for attended compared with unattended systolic AOBP when measurements were performed before and after conventional readings, respectively. A small bias was observed when unattended and attended systolic AOBP measurements were compared with daytime ambulatory blood pressure monitoring (1.3±13 and 0.6±13 mm Hg, respectively). Biases were higher for conventional OBP readings compared with unattended AOBP (-5.6±15 mm Hg for unattended AOBP and oscillometric OBP measured by a physician, -6.8±14 mm Hg for unattended AOBP and oscillometric OBP measured by a nurse, and -2.1±12 mm Hg for unattended AOBP and auscultatory OBP measured by a second physician). Our findings showed that independent of the presence or absence of medical staff, AOBP readings revealed similar values that were closer to daytime ambulatory blood pressure monitoring than conventional office readings, further supporting the use of AOBP in the clinical setting. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  17. Body mass index and blood pressure measurement during pregnancy.

    LENUS (Irish Health Repository)

    Hogan, Jennifer L

    2012-02-01

    OBJECTIVE: The accurate measurement of blood pressure requires the use of a large cuff in subjects with a high mid-arm circumference (MAC). This prospective study examined the need for a large cuff during pregnancy and its correlation with maternal obesity. METHODS: Maternal body mass index (BMI), fat mass, and MAC were measured. RESULTS: Of 179 women studied, 15.6% were obese. With a BMI of level 1 obesity, 44% needed a large cuff and with a BMI of level 2 obesity 100% needed a large cuff. CONCLUSION: All women booking for antenatal care should have their MAC measured to avoid the overdiagnosis of pregnancy hypertension.

  18. Combination of phlebography and sanguinous measurement of venous blood pressure

    International Nuclear Information System (INIS)

    Weber, J.

    1988-01-01

    Phlebographic visualisation offers the highest spatial resolution of all imaging methods both in respect of veins of the leg and pelvis and of the abdomen. Phlebography offers optimal conditions for assessing morphological changes at the veins and in their direct neighbourhood. No quantitative information is available via phlebography if haemodynamics are disturbed; qualitative information is yielded merely to a restricted extent (by assessing flow velocity and collaterals). Direct sanguinous measurement of venous blood pressure is particularly suitable for the quantitative and qualitative assessment of disturbed haemodynamic conditions; in this respect it stands out among the function tests based on the employment of apparatures. If it is combined with phlebography, it is possible not only to optimise the diagnostic yield in the hands of one investigator, but also to reduce the invasiveness of both methods to one single puncture, since the puncture needle is at the same time also an instrument to measure the pressure. The article points out the possibilities and limitations of combining a) ascending phlebography of the leg and pelvis with peripheral venous pressure measurement (phlebodynamometry) and b) visualisation of the veins of the pelvis and vena cava inferior with central sanguinous venous pressure measurement (CP). Indicatious and technical execution are described. (orig.) [de

  19. Central blood pressure and chronic kidney disease

    Science.gov (United States)

    Ohno, Yoichi; Kanno, Yoshihiko; Takenaka, Tsuneo

    2016-01-01

    In this review, we focused on the relationship between central blood pressure and chronic kidney diseases (CKD). Wave reflection is a major mechanism that determines central blood pressure in patients with CKD. Recent medical technology advances have enabled non-invasive central blood pressure measurements. Clinical trials have demonstrated that compared with brachial blood pressure, central blood pressure is a stronger risk factor for cardiovascular (CV) and renal diseases. CKD is characterized by a diminished renal autoregulatory ability, an augmented direct transmission of systemic blood pressure to glomeruli, and an increase in proteinuria. Any elevation in central blood pressure accelerates CKD progression. In the kidney, interstitial inflammation induces oxidative stress to handle proteinuria. Oxidative stress facilitates atherogenesis, increases arterial stiffness and central blood pressure, and worsens the CV prognosis in patients with CKD. A vicious cycle exists between CKD and central blood pressure. To stop this cycle, vasodilator antihypertensive drugs and statins can reduce central blood pressure and oxidative stress. Even in early-stage CKD, mineral and bone disorders (MBD) may develop. MBD promotes oxidative stress, arteriosclerosis, and elevated central blood pressure in patients with CKD. Early intervention or prevention seems necessary to maintain vascular health in patients with CKD. PMID:26788468

  20. Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences.

    Science.gov (United States)

    van der Hoeven, Niels V; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A; van den Born, Bert-Jan H

    2013-11-01

    There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age (simultaneous and three sequential BP measurements were taken in each patient. Starting measurement type and starting arm for sequential measurements were randomized. Mean BP and inter-arm BP differences of the first pair and reproducibility of inter-arm BP differences of the first and second pair were compared between both methods. Mean systolic BP was 1.3±7.5 mm Hg lower during sequential compared with simultaneous measurement (Psequential measurement was on average higher than the second, suggesting an order effect. Absolute systolic inter-arm BP differences were smaller on simultaneous (6.2±6.7/3.3±3.5 mm Hg) compared with sequential BP measurement (7.8±7.3/4.6±5.6 mm Hg, PSimultaneous measurement of BP at both arms reduces order effects and results in smaller inter-arm BP differences, thereby potentially reducing unnecessary referral and diagnostic procedures. ©2013 Wiley Periodicals, Inc.

  1. An Investigation of Pulse Transit Time as a Non-Invasive Blood Pressure Measurement Method

    International Nuclear Information System (INIS)

    McCarthy, B M; O'Flynn, B; Mathewson, A

    2011-01-01

    The objective of this paper is to examine the Pulse Transit Method (PTT) as a non-invasive means to track Blood Pressure over a short period of time. PTT was measured as the time it takes for an ECG R-wave to propagate to the finger, where it is detected by a photoplethysmograph sensor. The PTT method is ideal for continuous 24-hour Blood Pressure Measurement (BPM) since it is both cuff-less and non-invasive and therefore comfortable and unobtrusive for the patient. Other techniques, such as the oscillometric method, have shown to be accurate and reliable but require a cuff for operation, making them unsuitable for long term monitoring. Although a relatively new technique, the PTT method has shown to be able to accurately track blood pressure changes over short periods of time, after which re-calibration is necessary. The purpose of this study is to determine the accuracy of the method.

  2. Exploring pharmacist-customer communication: the established blood pressure measurement episode.

    Science.gov (United States)

    Cavaco, Afonso Neves; Romano, João P

    2010-10-01

    To characterize the communication ritual in the pharmacist-customer dyad during a blood pressure measurement and counselling episode. A Portuguese urban community pharmacy. An exploratory, cross-sectional design was used. Participants were purposively selected and data collected via audio recording, as well as demographics and clinical information via questionnaire. Encounters' verbal content was transcribed verbatim, utterances identified, time stamped, and classified according to a coding scheme of fifteen categories. All data was statistically analyzed using SPSSv17. Four dialogue structures: speaker turn, interactivity, turn density and turn duration measurements. From a total of 51 participants, 72.5% were female with a median age of 66 years. The average systolic blood pressure was 140 mmHg, while the diastolic was 78 mmHg. The blood pressure measurement episode lasted for 5:35 min, with an average of 81 utterances. From all utterances registered, 55.3% were produced by the customer. Visits averaged 38 speaker turns, with an interactivity rate of approximately 7 turns per episode minute. For pharmacists, turn duration averaged 7.0 s and turn density 2.1 utterances. The customers' turns comprised a mean of 8.0 s, with 2.4 utterances. Longer episodes were related to more speaker turns and greater customer turn density and duration, but lower dialogue interactivity. The interactivity rate was also lower when the customers' utterances increased. Pharmacists asked more questions (essentially closed ones), while the customers gave more information. No significant associations were observed between elderly/non-elderly and gender in relation to all communication variables. However, an increased number of speaker turns and closed-questions were associated to a higher systolic pressure. It seems that pharmacists tend to control the content of the dialogue, while customers have more influence on the visit duration and interactivity. Specific hypertensive episodes induce

  3. Oscillometric blood pressure measurement: a simple method in screening for peripheral arterial disease

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels; Bruce, Christopher

    2008-01-01

    Blood pressure at the ankle level is a reliable indicator of peripheral arterial disease (PAD) and the ankle brachial index (ABI) is a useful non-invasive screening tool for the early detection of atherosclerosis. In the first part of the study, systolic blood pressures obtained by oscillometry...... of PAD was sufficiently high in subjects over the age of 60 years to warrant screening. The ankle brachial index based on measurements with an oscillometric device was shown reliable in the exclusion of PAD, thereby fulfilling an important criterion for the use in screening....

  4. Inconsistency between simultaneous blood pressure measurements in the arm, forearm, and leg in anesthetized children.

    Science.gov (United States)

    Keidan, Ilan; Sidi, Avner; Ben-Menachem, Erez; Tene, Yael; Berkenstadt, Haim

    2014-02-01

    To determine the accuracy and precision of simultaneous noninvasive blood pressure (NIBP) measurement in the arm, forearm, and ankle in anesthetized children. Prospective, randomized study. University medical center. 101 ASA physical status 1 and 2 children (aged 1-8 yrs) scheduled for elective surgery with general anesthesia. Simultaneous NIBP measurements were recorded at the arm, forearm, and ankle at 5-minute intervals. The systolic blood pressure difference between the arm-forearm or the arm-ankle was within the ± 10% range in 63% and 29% of measurements, and within the ± 20% range in 85% and 67% of measurements, respectively. The diastolic blood pressure difference between the arm-forearm or the arm-ankle was within the ± 10% range in 42% and 44% and within the ± 20% range in 67% and 74% of measurements, respectively. In patients in whom the initial three NIBP measurements were within the ± 20% range between the forearm and arm, 86% of the subsequent measurements were also within that limit. Forearm and ankle NIBP measurements are unreliable and inconsistent with NIBP measured in the arm of anesthetized children. These alternative BP measurement sites are not reliable in accuracy (comparison with reference "gold" standard) and precision (reproducibility). Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Contributions of mean and shape of blood pressure distribution to worldwide trends and variations in raised blood pressure: a pooled analysis of 1018 population-based measurement studies with 88.6 million participants.

    Science.gov (United States)

    2018-03-19

    Change in the prevalence of raised blood pressure could be due to both shifts in the entire distribution of blood pressure (representing the combined effects of public health interventions and secular trends) and changes in its high-blood-pressure tail (representing successful clinical interventions to control blood pressure in the hypertensive population). Our aim was to quantify the contributions of these two phenomena to the worldwide trends in the prevalence of raised blood pressure. We pooled 1018 population-based studies with blood pressure measurements on 88.6 million participants from 1985 to 2016. We first calculated mean systolic blood pressure (SBP), mean diastolic blood pressure (DBP) and prevalence of raised blood pressure by sex and 10-year age group from 20-29 years to 70-79 years in each study, taking into account complex survey design and survey sample weights, where relevant. We used a linear mixed effect model to quantify the association between (probit-transformed) prevalence of raised blood pressure and age-group- and sex-specific mean blood pressure. We calculated the contributions of change in mean SBP and DBP, and of change in the prevalence-mean association, to the change in prevalence of raised blood pressure. In 2005-16, at the same level of population mean SBP and DBP, men and women in South Asia and in Central Asia, the Middle East and North Africa would have the highest prevalence of raised blood pressure, and men and women in the high-income Asia Pacific and high-income Western regions would have the lowest. In most region-sex-age groups where the prevalence of raised blood pressure declined, one half or more of the decline was due to the decline in mean blood pressure. Where prevalence of raised blood pressure has increased, the change was entirely driven by increasing mean blood pressure, offset partly by the change in the prevalence-mean association. Change in mean blood pressure is the main driver of the worldwide change in

  6. Invasively Measured Aortic Systolic Blood Pressure and Office Systolic Blood Pressure in Cardiovascular Risk Assessment: A Prospective Cohort Study

    DEFF Research Database (Denmark)

    Laugesen, Esben; Knudsen, Søren T; Hansen, Klavs W

    2016-01-01

    Aortic systolic blood pressure (BP) represents the hemodynamic cardiac and cerebral burden more directly than office systolic BP. Whether invasively measured aortic systolic BP confers additional prognostic value beyond office BP remains debated. In this study, office systolic BP and invasively......) and with myocardial infarction in patients without diabetes mellitus (hazard ratio, 1.07 [95% confidence interval, 1.02-1.12] and 1.05 [95% confidence interval, 1.01-1.10], respectively). In models including both BP measurements, aortic BP lost statistical significance and aortic BP did not confer improvement...

  7. High Blood Pressure

    Science.gov (United States)

    ... normal blood pressure 140/90 or higher is high blood pressure Between 120 and 139 for the top number, ... prehypertension. Prehypertension means you may end up with high blood pressure, unless you take steps to prevent it. High ...

  8. The measurement of digital systolic blood pressure by strain gauge technique

    DEFF Research Database (Denmark)

    Nielsen, P E; Bell, G; Lassen, N A

    1972-01-01

    The systolic blood pressure on the finger, toe, and ankle has been measured by a strain gauge technique in 10 normal subjects aged 17-31 years and 14 normal subjects aged 43-57 years. The standard deviation in repeated measurements lies between 2 and 6 mm Hg. The finger pressure in the younger...... group was significantly higher than the corresponding arm pressure (+ 9.3 mm Hg, S.D. 6.8), but equalled this in the older group (- 0.5 mm Hg, S.D. 6.6). In the two groups the ankle pressures were + 19.3 mm Hg (S.D. 7.5) and + 23.6 mm Hg (S.D. 9.5) higher than the systolic arm pressures. The toe...... pressures were lower than the arm pressures, in the two groups - 4.8 mm Hg (S.D. 6.6) and - 9.8 mm Hg (S.D. 10.7) respectively. The ankle-toe gradient was in the younger group 24.3 mm Hg (S.D. 7.3) and in the older group 33.3 mm Hg (S.D. 12.1). Using mean minus 2.5 X S.D. as the lower limit of normality...

  9. [Central blood pressure and vascular damage].

    Science.gov (United States)

    Pérez-Lahiguera, Francisco; Rodilla, Enrique; Costa, José Antonio; Pascual, José María

    2015-07-20

    The aim of this study was to assess the relationship between central blood pressure and vascular damage. This cross-sectional study involved 393 never treated hypertensive patients (166 women). Clinical blood pressure (BP), 24h blood pressure (BP24h) and central blood pressure (CBP) were measured. Vascular organ damage (VOD) was assessed by calculating the albumin/creatinine ratio (ACR), wave pulse pressure velocity and echocardiographic left ventricular mass index (LVMI). Patients with VOD had higher values of BP, BP24h, and CBP than patients without ACR. When comparing several systolic BP, systolic BP24h had a higher linear correlation with CBP (Z Steiger test: 2.26; P=.02) and LVMI (Z Steiger test: 3.23; P=.01) than PAC. In a multiple regression analysis corrected by age, sex and metabolic syndrome, all pressures were related with VOD but systolic BP24h showed the highest correlation. In a logistic regression analysis, having the highest tercile of systolic BP24h was the stronger predictor of VOD (multivariate odds ratio: 3.4; CI 95%: 2.5-5.5, P=.001). CBP does not have more correlation with VOD than other measurements of peripheral BP. Systolic BP24h is the BP measurement that best predicts VOD. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  10. Low Blood Pressure (Hypotension)

    Science.gov (United States)

    ... lowest at night and rises sharply on waking. Blood pressure: How low can you go? What's considered low ... low blood pressure. Medications that can cause low blood pressure Some medications can cause low blood pressure, including: ...

  11. Laser Doppler flowmetry for bone blood flow measurement: correlation with microsphere estimates and evaluation of the effect of intracapsular pressure on femoral head blood flow

    International Nuclear Information System (INIS)

    Swiontkowski, M.F.; Tepic, S.; Perren, S.M.; Moor, R.; Ganz, R.; Rahn, B.A.

    1986-01-01

    Laser Doppler flowmetry (LDF) was used to measure bone blood flow in the rabbit femoral condyles. To correlate the LDF output signal blood cell flux to in vivo blood flow, simultaneous measurements using LDF and 85 Sr-labeled microspheres were made in an adult rabbit model. There was no correlation between the two methods for blood flow in the femoral condyles and the correlation between the two methods for blood flow in the femoral head does not achieve statistical significance. An LDF signal of 0.4 V was approximately equal to a microsphere measured flow rate of 0.4 ml blood/g bone/min. The strength of the correlation in the latter case may have been affected by (a) large arteriovenous shunts, (b) inadequate mixing of the microspheres with a left ventricular injection, and (c) insufficient numbers of microspheres present in the bone samples. When LDF was used to evaluate the effect of elevated intracapsular pressure on femoral head blood flow in skeletally mature rabbits, femoral head subchondral bone blood flow declined with increasing intracapsular pressure from a baseline value of 0.343 +/- 0.036 to a value of 0.127 +/- 0.27 at 120 cm of water pressure. The decline in femoral head blood flow was statistically significant at pressures of 40 cm of water or higher (p less than 0.001), and evaluation of sections of the proximal femora made from preterminal disulphine blue injections confirmed these findings. Intracapsular tamponade has an adverse effect on femoral head blood flow beginning well below central venous pressure and should be considered in the pathophysiology of posttraumatic and nontraumatic necrosis of the femoral head. Laser Doppler flowmetry was easy to use and appears to be a reproducible technique for evaluating femoral head blood flow, offering distinct advantages over the microsphere technique for measuring bone blood flow

  12. Cantilever arrayed blood pressure sensor for arterial applanation tonometry.

    Science.gov (United States)

    Lee, Byeungleul; Jeong, Jinwoo; Kim, Jinseok; Kim, Bonghwan; Chun, Kukjin

    2014-03-01

    The authors developed a cantilever-arrayed blood pressure sensor array fabricated by (111) silicon bulk-micromachining for the non-invasive and continuous measurement of blood pressure. The blood pressure sensor measures the blood pressure based on the change in the resistance of the piezoresistor on a 5-microm-thick-arrayed perforated membrane and 20-microm-thick metal pads. The length and the width of the unit membrane are 210 and 310 microm, respectively. The width of the insensible zone between the adjacent units is only 10 microm. The resistance change over contact force was measured to verify the performance. The good linearity of the result confirmed that the polydimethylsiloxane package transfers the forces appropriately. The measured sensitivity was about 4.5%/N. The maximum measurement range and the resolution of the fabricated blood pressure sensor were greater than 900 mmHg (= 120 kPa) and less than 1 mmHg (= 133.3 Pa), respectively.

  13. Hypertension (High Blood Pressure)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Hypertension (High Blood Pressure) KidsHealth / For Teens / Hypertension (High Blood Pressure) What's ... rest temperature diet emotions posture medicines Why Is High Blood Pressure Bad? High blood pressure means a person's heart ...

  14. Letter to editor: Blood pressure, hypertension and lead exposure.

    Science.gov (United States)

    Yang, Wen-Yi; Staessen, Jan A

    2018-02-19

    A significant association of office diastolic blood pressure with low-level blood lead exposure was reported in a Brazilian adult population. However, caution should be taken to interpret these results. The multivariable-adjusted association with blood pressure was positive for diastolic blood pressure, but inverse for systolic blood pressure. The association sizes were infinitesimal without clinical relevance. The outcome measures, i.e. blood pressure and the prevalence of hypertension were analysed across categories of the blood lead distribution - not in relation to blood lead as continuous variable. Blood pressure was the average of two oscillometric office readings, whereas ambulatory monitoring is the state-of-the-art.

  15. Correlates of blood pressure in Yanomami Indians of northwestern Brazil.

    Science.gov (United States)

    Crews, D E; Mancilha-Carvalho, J J

    1993-01-01

    We determined associations of measures of body habitus with blood pressure for 100 adult Yanomami Indians (61 men, 39 women) examined during February and March 1990. Measurements included body weight and height, four skinfolds (triceps, subscapular, suprailiac, abdomen), four circumferences (wrist, upper arm, abdomen, hip), systolic and diastolic blood pressures, pulse rate, and estimated age. Various indices of fat distribution were determined from the measurements of skinfolds, circumferences, weight, and height. Estimated age averaged 35.0 years in men and 33.4 years in women (range: 15 to 63 years). Mean systolic and diastolic blood pressures were low in both men (104.8/70.4 mm Hg) and women (94.8/63.5 mm Hg), as was body mass index (men: 20.7; women: 21.4 kg/m2). In Yanomami women, all four skinfolds, wrist circumference, and the indices of hip and abdominal fat were significant correlates of systolic blood pressure, while the abdominal skinfold and wrist and hip circumferences correlated significantly with diastolic blood pressure. Among men, there was a negative correlation between estimated age and systolic blood pressure and a positive correlation between BMI and upper arm and hip circumferences and systolic blood pressure. There was a significant positive correlation between wrist, upper arm, and hip circumferences and diastolic blood pressure among Yanomami men. We used stepwise regression to generate sex-specific predictive equations for blood pressure. For men, estimated age and hip circumference, and for women, abdominal skinfold measurement and age were included in the model for systolic blood pressure. Among men, wrist circumference and height, and among women, wrist circumference alone entered the model for diastolic blood pressure. On the basis of these results, we suggest that even in a low-blood pressure, low-body fat, no-salt setting, systolic blood pressure is associated with the amount and placement of adipose tissue. However, diastolic blood

  16. Peripheral arterial volume distensibility: significant differences with age and blood pressure measured using an applied external pressure

    International Nuclear Information System (INIS)

    Zheng, Dingchang; Murray, Alan

    2011-01-01

    A new arterial distensibility measurement technique was assessed in 100 healthy normotensive subjects. Arterial transmural pressures on the whole right arm were reduced with a 50 cm long cuff inflated to 10, 20, 30 and 40 mmHg. The electrocardiogram, and finger and ear photoplethysmograms were recorded simultaneously. Arm pulse propagation time, pulse wave velocity (PWV) and arterial volume distensibility were determined. With a 40 mmHg reduction in transmural pressure, arm pulse propagation time increased from 61 to 83 ms, PWV decreased from 12 to 8 m s −1 and arterial distensibility increased from 0.102% to 0.232% per mmHg (all P < 0.0001). At all cuff pressures, arterial distensibility was significantly related to resting mean arterial pressure (MAP), diastolic blood pressure (DBP) and age, and for systolic blood pressure at 30 and 40 mmHg (all P < 0.05). At 40 mmHg cuff pressure, arterial distensibility fell by 54% for a MAP increase from 75 to 105 mmHg, 57% for a DBP increase from 60 to 90 mmHg and 47% for an age increase from 20 to 70 years. These changes were more than double than those without cuff pressure. Our technique showed that systemic volume distensibility of the peripheral arm artery reduced with age, with a greater effect at higher external and lower transmural pressures

  17. Heat-washout measurements compared to distal blood pressure and perfusion in orthopaedic patients with foot ulcers

    DEFF Research Database (Denmark)

    Midttun, M; Azad, B B S; Broholm, R

    2015-01-01

    Distal blood pressure and local skin perfusion pressure were compared to measurement of blood flow rate (BFR) measured by the heat-washout method in orthopaedic patients with and without diabetes, all with a foot ulcer in one foot, compared to healthy controls. The correlation was good between heat......-washout and distal blood pressure in patients with diabetes with and without an ulcer (P = 0·024 and 0·059, respectively). The correlation was weak in patients without diabetes with and without an ulcer, most probably due to power problems (P = 0·118 and 0·116, respectively). The correlation in the healthy controls...... the surrounding tissue, and therefore, measurements are easier made in these subjects. BFR in the first toe increased significantly in all patients when the foot was moved from heart level to 50 cm below heart level (P = between 0·03 and 0·05) as previously seen in patients with claudication...

  18. Ambulatory blood pressure profiles in familial dysautonomia.

    Science.gov (United States)

    Goldberg, Lior; Bar-Aluma, Bat-El; Krauthammer, Alex; Efrati, Ori; Sharabi, Yehonatan

    2018-02-12

    Familial dysautonomia (FD) is a rare genetic disease that involves extreme blood pressure fluctuations secondary to afferent baroreflex failure. The diurnal blood pressure profile, including the average, variability, and day-night difference, may have implications for long-term end organ damage. The purpose of this study was to describe the circadian pattern of blood pressure in the FD population and relationships with renal and pulmonary function, use of medications, and overall disability. We analyzed 24-h ambulatory blood pressure monitoring recordings in 22 patients with FD. Information about medications, disease severity, renal function (estimated glomerular filtration, eGFR), pulmonary function (forced expiratory volume in 1 s, FEV1) and an index of blood pressure variability (standard deviation of systolic pressure) were analyzed. The mean (± SEM) 24-h blood pressure was 115 ± 5.6/72 ± 2.0 mmHg. The diurnal blood pressure variability was high (daytime systolic pressure standard deviation 22.4 ± 1.5 mmHg, nighttime 17.2 ± 1.6), with a high frequency of a non-dipping pattern (16 patients, 73%). eGFR, use of medications, FEV1, and disability scores were unrelated to the degree of blood pressure variability or to dipping status. This FD cohort had normal average 24-h blood pressure, fluctuating blood pressure, and a high frequency of non-dippers. Although there was evidence of renal dysfunction based on eGFR and proteinuria, the ABPM profile was unrelated to the measures of end organ dysfunction or to reported disability.

  19. Worldwide trends in blood pressure from 1975 to 2015

    DEFF Research Database (Denmark)

    Linneberg, Allan René; Sørensen, Thorkild I.A.

    2017-01-01

    BACKGROUND: Raised blood pressure is an important risk factor for cardiovascular diseases and chronic kidney disease. We estimated worldwide trends in mean systolic and mean diastolic blood pressure, and the prevalence of, and number of people with, raised blood pressure, defined as systolic blood...... pressure of 140 mm Hg or higher or diastolic blood pressure of 90 mm Hg or higher. METHODS: For this analysis, we pooled national, subnational, or community population-based studies that had measured blood pressure in adults aged 18 years and older. We used a Bayesian hierarchical model to estimate trends...... from 1975 to 2015 in mean systolic and mean diastolic blood pressure, and the prevalence of raised blood pressure for 200 countries. We calculated the contributions of changes in prevalence versus population growth and ageing to the increase in the number of adults with raised blood pressure. FINDINGS...

  20. Diagnostic accuracy of manual office blood pressure measurement in ambulatory hypertensive patients in Korea.

    Science.gov (United States)

    Kim, Sehun; Park, Jin Joo; Lee, Seung-Ah; Cho, Youngjin; Yoon, Yeonyee E; Oh, Il-Young; Yoon, Chang-Hwan; Suh, Jung-Won; Cho, Young-Seok; Youn, Tae-Jin; Cho, Goo-Yeong; Chae, In-Ho; Lee, Hae-Young; Shin, Jinho; Park, Sungha; Choi, Dong-Ju

    2018-01-01

    Currently, office blood pressure (OBP) is the most widely used method of measuring blood pressure (BP) in daily clinical practice. However, data on the diagnostic accuracy of OBP in reference to ambulatory blood pressure (ABP) are scarce in Korea. In retrospective and prospective cohorts, manual OBP and ABP measurements were compared among ambulatory hypertensive patients. Hypertension was defined as systolic OBP ≥ 140 mmHg and/or diastolic OBP ≥ 90 mmHg, and systolic ABP ≥ 130 mmHg and/or diastolic ABP ≥ 80 mmHg. In the retrospective cohort (n = 903), the mean OBP1 (before ABP measurement) was higher than ABP in both systolic (138 ± 17 mmHg vs. 123 ± 13 mmHg, p ABP ( r 2 = 0.038, p ABP, which is the reference method for measuring BP, was 43.9%. The prospective cohort (n = 57) showed similar results. In a subgroup analysis, male patients had higher false negative results (masked or under-treated hypertension) than did female patients (26.1% vs. 17.8%, p = 0.003), whereas female patients had a higher false positive rate (white-coat or over-treated hypertension) than did male patients (28.7% vs. 15.2%, p ABP. Men and women have different patterns of discordance. These findings indicate that management of hypertensive patients with manual OBP measurements may be suboptimal and encourages the use of ABP in ambulatory hypertensive patients.

  1. Number of blood pressure measurements needed for screening of hypertension in children and adolescents

    Directory of Open Access Journals (Sweden)

    Madarina Julia

    2009-08-01

    Conclusions It is necessary to measure blood pressure repeatedly to minimize the risk of over-diagnosing in hypertension in children and adolescents. Using the average of three measurements in three visits is recommended, but drawing conclusions based on two measurements in two occasions have yielded sufficiently high specificity.

  2. COMPARISON OF HIGH-DEFINITION OSCILLOMETRIC AND DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT IN ANESTHETIZED CHEETAHS (ACINONYX JUBATUS).

    Science.gov (United States)

    Sant Cassia, Emma V; Boswood, Adrian; Tordiffe, Adrian S W

    2015-09-01

    Blood pressure measurement reveals important insights into the health of conscious and anesthetized individuals. This is of particular interest in cheetahs (Acinonyx jubatus), which in captivity are known to suffer from chronic diseases that may be associated with hypertension and which often require immobilization for transport or veterinary treatment. Invasive testing methods are considered the gold standard but are not practical in many settings. Consequently, it is important to evaluate the use of noninvasive methods in this species. Measurements for systolic, diastolic, and mean arterial pressure obtained using high-definition oscillometry (HDO) at the coccygeal artery were compared to simultaneous direct measurements obtained via catheterization of the femoral or dorsal pedal artery in eight anesthetized captive cheetahs during nine anesthetic events. Overall, HDO and direct measurements agreed most closely for mean arterial pressure, and the poorest agreement was observed for systolic pressure. There was a tendency for low diastolic pressures to be underestimated and for high diastolic pressures to be overestimated. Across all three parameters, HDO measurements from the tail overestimated directly measured pressures in the femoral artery and underestimated those in the dorsal pedal artery. HDO agreed most closely with directly measured dorsal pedal pressures. Mean arterial pressure showed the greatest precision (standard deviation of 10.2 mm Hg) and lowest bias (-1.2 mm Hg), with 75.9% of readings within 10 mm Hg of the direct dorsal pedal pressure. Agreement with systolic pressure was hindered by a high bias (-10.4 mm Hg), but if a correction factor of +10 mm Hg was applied to all systolic measurements, agreement was improved and 65.7% of readings were within 10 mm Hg of the direct pressure. When compared to criteria defined by the American College of Veterinary Internal Medicine for validation of blood pressure devices, results were favorable, but a

  3. Office blood pressure or ambulatory blood pressure for the prediction of cardiovascular events

    DEFF Research Database (Denmark)

    Mortensen, Rikke Nørmark; Gerds, Thomas Alexander; Jeppesen, Jørgen Lykke

    2017-01-01

    Aims: To determine the added value of (i) 24-h ambulatory blood pressure relative to office blood pressure and (ii) night-time ambulatory blood pressure relative to daytime ambulatory blood pressure for 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events. Methods...... and results: A total of 7927 participants were included from the International Database on Ambulatory blood pressure monitoring in relation to Cardiovascular Outcomes. We used cause-specific Cox regression to predict 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events....... Discrimination of 10-year outcomes was assessed by time-dependent area under the receiver operating characteristic curve (AUC). No differences in predicted risks were observed when comparing office blood pressure and ambulatory blood pressure. The median difference in 10-year risks (1st; 3rd quartile) was -0...

  4. Prognostic significance of distal blood pressure measurements in patients with severe ischaemia

    DEFF Research Database (Denmark)

    Paaske, William; Tønnesen, K H

    1980-01-01

    The clinical course was followed and the ankle and toe blood pressures were measured with the strain gauge technique on 5 occasions during 2 years in 43 patients with pain at rest and/or ischaemic ulceration due to severe ischaemia of the legs on the basis of occlusive arterial disease. Although...

  5. Classification of peripheral occlusive arterial diseases based on symptoms, signs and distal blood pressure measurements

    DEFF Research Database (Denmark)

    Tønnesen, K H; Noer, Ivan; Paaske, William

    1980-01-01

    Systolic blood pressures at toe and ankle were measured in 459 consecutive patients with occlusive arterial disease. Fifty-eight per cent had intermittent claudication with arterial disease of all degrees of severity. Seventeen per cent complained of rest pain having toe systolic pressures below 30...

  6. Segmental blood pressure after total hip replacement

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Soelberg, M; Henriksen, Jens Henrik Sahl

    1992-01-01

    Twenty-nine patients due to have a total hip replacement had their systemic systolic and segmental blood pressures measured prior to operation and 1 and 6 weeks postoperatively. No patients had signs of ischemia. The segmental blood pressure was measured at the ankle and at the toes. A significant...... drop was found in all pressures 1 week postoperatively. The decrease followed the systemic pressure and was restored to normal after 6 weeks. In a group of six patients with preoperatively decreased ankle pressure, a significant transient further decrease in the ankle-toe gradient pressure was found...... on the operated side. None of the patients had symptoms from the lowered pressure. We conclude that in patients without signs of ischemia, the postoperative segmental pressure decrease is reversible and therefore not dangerous....

  7. Agreement between specific measures of adiposity and associations with high blood pressure in black South African women.

    Science.gov (United States)

    Kruger, Herculina S; Botha-Ravyse, Chrisna; Havemann-Nel, Lize; Doubell, Maretha; van Rooyen, Johannes M

    2017-11-01

    To derive percentage body fat (%BF) cut-points according to body mass index (BMI) categories for adult black South African women and to investigate the agreement between adiposity classifications according to WHO BMI and %BF cut-points. The secondary aim was to determine the association between these different adiposity measures and high blood pressure. Black women aged 29-65 years (n = 435) from Ikageng, South Africa, were included in this cross-sectional study. Socio-demographic and anthropometric data were collected (weight, height and BMI). %BF using dual-energy X-ray absorptiometry and blood pressure were measured. There was significant agreement between three %BF categories: low/normal (high blood pressure (OR = 1.75, 95% CI 1.09-2.81 versus OR = 1.92, 95% CI 1.15-3.23, respectively). Despite significant agreement between BMI and %BF categories, considerable misclassification occurred in the overweight range. Participants with excessive %BF had a greater odds of high blood pressure than those in the highest BMI category. © 2017 Wiley Periodicals, Inc.

  8. Blood pressure modifies retinal susceptibility to intraocular pressure elevation.

    Directory of Open Access Journals (Sweden)

    Zheng He

    Full Text Available Primary open angle glaucoma affects more than 67 million people. Elevated intraocular pressure (IOP is a risk factor for glaucoma and may reduce nutrient availability by decreasing ocular perfusion pressure (OPP. An interaction between arterial blood pressure and IOP determines OPP; but the exact contribution that these factors have for retinal function is not fully understood. Here we sought to determine how acute modifications of arterial pressure will affect the susceptibility of neuronal function and blood flow to IOP challenge. Anaesthetized (ketamine:xylazine Long-Evan rats with low (∼60 mmHg, sodium nitroprusside infusion, moderate (∼100 mmHg, saline, or high levels (∼160 mmHg, angiotensin II of mean arterial pressure (MAP, n = 5-10 per group were subjected to IOP challenge (10-120 mmHg, 5 mmHg steps every 3 minutes. Electroretinograms were measured at each IOP step to assess bipolar cell (b-wave and inner retinal function (scotopic threshold response or STR. Ocular blood flow was measured using laser-Doppler flowmetry in groups with similar MAP level and the same IOP challenge protocol. Both b-wave and STR amplitudes decreased with IOP elevation. Retinal function was less susceptible to IOP challenge when MAP was high, whereas the converse was true for low MAP. Consistent with the effects on retinal function, higher IOP was needed to attenuated ocular blood flow in animals with higher MAP. The susceptibility of retinal function to IOP challenge can be ameliorated by acute high BP, and exacerbated by low BP. This is partially mediated by modifications in ocular blood flow.

  9. Ambulatory heart rate is underestimated when measured by an Ambulatory Blood Pressure device

    NARCIS (Netherlands)

    Vrijkotte, T.G.M.; de Geus, E.J.C.

    1999-01-01

    Objective: To test the validity of ambulatory heart rate (HR) assessment with a cuff ambulatory blood pressure (ABP) monitor. Design: Cross-instrument comparison of HR measured intermittently by a cuff ABP monitor (SpaceLabs, Redmond, Washington, USA), with HR derived from continuous

  10. Ambulatory heart rate is underestimated when measured by an ambulatory blood pressure device

    NARCIS (Netherlands)

    Vrijkotte, T. G.; de Geus, E. J.

    2001-01-01

    To test the validity of ambulatory heart rate (HR) assessment with a cuff ambulatory blood pressure (ABP) monitor. Cross-instrument comparison of HR measured intermittently by a cuff ABP monitor (SpaceLabs, Redmond, Washington, USA), with HR derived from continuous electrocardiogram (ECG) recordings

  11. Ambulatory heart rate is underestimated when measured by an ambulatory blood pressure device

    NARCIS (Netherlands)

    Vrijkotte, T.G.M.; de Geus, E.J.C.

    2001-01-01

    Objective: To test the validity of ambulatory heart rate (HR) assessment with a cuff ambulatory blood pressure (ABP) monitor. Design: Cross-instrument comparison of HR measured intermittently by a cuff ABP monitor (SpaceLabs, Redmond, Washington, USA), with HR derived from continuous

  12. High Blood Pressure Facts

    Science.gov (United States)

    ... Stroke Heart Disease Cholesterol Salt Million Hearts® WISEWOMAN High Blood Pressure Facts Recommend on Facebook Tweet Share Compartir On ... Top of Page CDC Fact Sheets Related to High Blood Pressure High Blood Pressure Pulmonary Hypertension Heart Disease Signs ...

  13. High Blood Pressure (Hypertension)

    Science.gov (United States)

    ... Print Page Text Size: A A A Listen High Blood Pressure (Hypertension) Nearly 1 in 3 American adults has ... weight. How Will I Know if I Have High Blood Pressure? High blood pressure is a silent problem — you ...

  14. Intensive versus conventional blood pressure monitoring in a general practice population. The Blood Pressure Reduction in Danish General Practice trial: a randomized controlled parallel group trial

    DEFF Research Database (Denmark)

    Klarskov, Pia; Bang, Lia E; Schultz-Larsen, Peter

    2018-01-01

    To compare the effect of a conventional to an intensive blood pressure monitoring regimen on blood pressure in hypertensive patients in the general practice setting. Randomized controlled parallel group trial with 12-month follow-up. One hundred and ten general practices in all regions of Denmark....... One thousand forty-eight patients with essential hypertension. Conventional blood pressure monitoring ('usual group') continued usual ad hoc blood pressure monitoring by office blood pressure measurements, while intensive blood pressure monitoring ('intensive group') supplemented this with frequent...... a reduction of blood pressure. Clinical Trials NCT00244660....

  15. Effects of external pressure loading on human skin blood flow measured by 133Xe clearance

    International Nuclear Information System (INIS)

    Holloway, G.A. Jr.; Daly, C.H.; Kennedy, D.; Chimoskey, J.

    1976-01-01

    Forearm skin blood flow was measured during external pressure loading in normal human subjects using 133 Xe washout from intracutaneous injection sites. Pressures ranging between 5 and 150 mmHg were applied through a 3-cm-diameter disc placed over the site of flow determination. The pressure was maintained constant by a servo-controlled loading mechanism. Flow decreased with pressures from 5 to 10 and 30 to 150 mmHg, but remained constant with pressures from 10 to 30 mmHg. Reactive hyperemia occurred following removal of pressures of 90 mmHg or greater, but did not occur following removal of lower pressures. The pressure-flow curve for parasacral skin of paraplegic subjects closely paralleled the pressure-flow curve of normal skin at pressures tested: 5 to 15 mmHg. These data are interpreted to demonstrate autoregulation of skin blood flow. Autoregulation in parasacral skin of paraplegic subjects suggests a peripheral mechanism. The occurrence of hyperemia at pressures which exceed the ability of skin to autoregulate suggests that both autoregulation and post occlusion hyperemia may have the same mechanism

  16. EVALUATION OF THE BLOOD PRESSURE MEASURING KNOWLEDGE OF THE NURSES WHO ARE WORKING IN A MEDICAL FACULTY HOSPITAL

    Directory of Open Access Journals (Sweden)

    Tahir Kemal SAHIN

    2006-02-01

    Full Text Available Objective: The aim of this study is to determine the right knowledge of blood pressure measurement of the nurses who working in clinics. Materials and Method: 103 nurses who are working in Meram Medical Faculty Hospital were included to this descriptive study. Sampling method was stratified proportional random sampling method, with strata for the number of nurses at clinics. A questionnaire, which was formed of some questions about standard measuring methods of blood pressure, was applied to the nurses. Results: It was determined that 55.3% to 98.1% of the nurses answered the most of the questions correctly. But, they gave different answers to the questions about choosing the arm for measurement, inflation level of the cuff, deflation speed and how many measurements should be done for true result. It was found that the female nurses had much more knowledge about the tension of wrapping the cuff around the arm and the correct positioning of the stethescope than the male ones. Oppositely, the male nurses had higher correct answer rate about deflation of the cuff than the female nurses. Conclusion: It was concluded that the knowledge of blood pressure measurement of the nurses was partly insufficient. Periodical educational studies should be done for the nurses to complete the blood pressure measurement knowledge of them. [TAF Prev Med Bull 2006; 5(1.000: 8-18

  17. A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study

    NARCIS (Netherlands)

    Schoot, T.S.; Weenk, M.; Belt, T.H. van de; Engelen, L.J.L.P.G.; Goor, H. van; Bredie, S.J.H.

    2016-01-01

    BACKGROUND: Cuffless blood pressure (BP) monitoring devices, based on pulse transit time, are being developed as an easy-to-use, more convenient, fast, and relatively cheap alternative to conventional BP measuring devices based on cuff occlusion. Thereby they may provide a great alternative to BP

  18. [Determination of arm circumference for correct measurement of blood pressure. Results of an intervention study].

    Science.gov (United States)

    Oliveras Puig, A; Dalfó-Pibernat, A; Jdid Rosàs, N; Mayor Isaac, E; Pérez-Romero, L; Gibert Llorach, E; Dalfó-Baqué, A

    2015-01-01

    To assess the effectiveness of an intervention to promote standardized arm circumference measurement as way to choose appropriate cuff size to measure blood pressure. A before-after intervention study was performed in a basic health care area in Barcelona. Doctors, nurses and pharmacy staff participated by filling out an anonymous self-administered questionnaire pre- and post-intervention (3m). Variables included: demographics, type of professional, years since they finished their studies, availability of different cuff sizes, if arm circumference measurement were obtained or not, knowledge about the cutoff values for each cuff size and type of blood pressure monitor. The written results were given to the participants and presented in sessions. Pre- and post-intervention: 74.3 and 67.3% answered the questionnaires (P=ns), respectively. Determination of arm circumference varied from 1.3 to 19.1% (P=.009). A total of 37.3% and 44.1% declared that they had 2 or more available cuff sizes (P=ns). Knowledge about the correct measurement of the cuffs was 2.7 to 33.8% regarding the standard cuff size (P=.0198) and 0 to 23.5% for obese subjects (P<.05). When more than one cuff was available, reasons for the choice went from: «making a rough guess» or «when velcro stops sticking» before and after the intervention. All blood pressure devices in our primary health care center were electronic and automatic as were those of the 9 pharmacies. The intervention increased the determination of arm circumference prior to the reading of the blood pressure and the knowledge about the cutoff interval for standard and obese cuff size after intervention. There was greater availability of different sized cuffs. Despite this, the choice of the appropriate cuff size was not made based on arm circumference. Copyright © 2014 SEHLELHA. Published by Elsevier Espana. All rights reserved.

  19. Increased nocturnal blood pressure in enuretic children with polyuria.

    Science.gov (United States)

    Kruse, Anne; Mahler, Birgitte; Rittig, Soren; Djurhuus, Jens Christian

    2009-10-01

    We investigated the association between nocturnal blood pressure and urine production in children with enuresis. A total of 39 consecutive children with a mean age of 9.8 years (range 6.2 to 14.9) with monosymptomatic nocturnal enuresis completed a bladder diary, including 2 weeks of basic documentation and 2 with desmopressin titration from 120 to 240 microg sublingually. Arterial blood pressure was measured every 30 minutes during 24 hours and during 4 additional nights using an ambulatory blood pressure monitor. Furthermore, 10 healthy children were recruited into the study who completed a bladder diary for 5 days while measuring arterial blood pressures with documentation of all intake and voided volumes. Patients with nocturnal polyuria had significantly higher nocturnal mean arterial pressure than patients without polyuria and controls (p polyuria than in children without polyuria. There was a significant positive correlation between average nocturnal mean arterial pressure and nocturnal urine volume in the whole study. The association between nocturnal blood pressure and urine volume, and the role of blood pressure should be investigated in a larger group of children with enuresis who have nocturnal polyuria.

  20. Blood pressure associates with standing balance in elderly outpatients.

    Directory of Open Access Journals (Sweden)

    Jantsje H Pasma

    Full Text Available OBJECTIVES: Assessment of the association of blood pressure measurements in supine and standing position after a postural change, as a proxy for blood pressure regulation, with standing balance in a clinically relevant cohort of elderly, is of special interest as blood pressure may be important to identify patients at risk of having impaired standing balance in routine geriatric assessment. MATERIALS AND METHODS: In a cross-sectional cohort study, 197 community-dwelling elderly referred to a geriatric outpatient clinic of a middle-sized teaching hospital were included. Blood pressure was measured intermittently (n = 197 and continuously (subsample, n = 58 before and after a controlled postural change from supine to standing position. The ability to maintain standing balance was assessed during ten seconds of side-by-side, semi-tandem and tandem stance, with both eyes open and eyes closed. Self-reported impaired standing balance and history of falls were recorded by questionnaires. Logistic regression analyses were used to examine the association between blood pressure and 1 the ability to maintain standing balance; 2 self-reported impaired standing balance; and 3 history of falls, adjusted for age and sex. RESULTS: Blood pressure decrease after postural change, measured continuously, was associated with reduced ability to maintain standing balance in semi-tandem stance with eyes closed and with increased self-reported impaired standing balance and falls. Presence of orthostatic hypotension was associated with reduced ability to maintain standing balance in semi-tandem stance with eyes closed for both intermittent and continuous measurements and with increased self-reported impaired standing balance for continuous measurements. CONCLUSION: Continuous blood pressure measurements are of additional value to identify patients at risk of having impaired standing balance and may therefore be useful in routine geriatric care.

  1. Pulse Oximeter Derived Blood Pressure Measurement in Patients With a Continuous Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Hellman, Yaron; Malik, Adnan S; Lane, Kathleen A; Shen, Changyu; Wang, I-Wen; Wozniak, Thomas C; Hashmi, Zubair A; Munson, Sarah D; Pickrell, Jeanette; Caccamo, Marco A; Gradus-Pizlo, Irmina; Hadi, Azam

    2017-05-01

    Currently, blood pressure (BP) measurement is obtained noninvasively in patients with continuous flow left ventricular assist device (LVAD) by placing a Doppler probe over the brachial or radial artery with inflation and deflation of a manual BP cuff. We hypothesized that replacing the Doppler probe with a finger-based pulse oximeter can yield BP measurements similar to the Doppler derived mean arterial pressure (MAP). We conducted a prospective study consisting of patients with contemporary continuous flow LVADs. In a small pilot phase I inpatient study, we compared direct arterial line measurements with an automated blood pressure (ABP) cuff, Doppler and pulse oximeter derived MAP. Our main phase II study included LVAD outpatients with a comparison between Doppler, ABP, and pulse oximeter derived MAP. A total of five phase I and 36 phase II patients were recruited during February-June 2014. In phase I, the average MAP measured by pulse oximeter was closer to arterial line MAP rather than Doppler (P = 0.06) or ABP (P < 0.01). In phase II, pulse oximeter MAP (96.6 mm Hg) was significantly closer to Doppler MAP (96.5 mm Hg) when compared to ABP (82.1 mm Hg) (P = 0.0001). Pulse oximeter derived blood pressure measurement may be as reliable as Doppler in patients with continuous flow LVADs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  2. [Blood pressure variability: clinical interest or simple curiosity?].

    Science.gov (United States)

    Ciaroni, Stefano

    2007-03-14

    Blood pressure variability is a physiological phenomenon influenced by many internal and external factors. This variability could be also influenced by pathological conditions such as arterial hypertension. Two forms must be mainly distinguished: the blood pressure variability at long and short-term. The latter could only be studied by continuous recordings. In this article will be analysed the interest of measuring blood pressure variability, its cardiovascular prognosis and the therapeutic tools when it is increased.

  3. Adaptive control with self-tuning for non-invasive beat-by-beat blood pressure measurement.

    Science.gov (United States)

    Nogawa, Masamichi; Ogawa, Mitsuhiro; Yamakoshi, Takehiro; Tanaka, Shinobu; Yamakoshi, Ken-ichi

    2011-01-01

    Up to now, we have successfully carried out the non-invasive beat-by-beat measurement of blood pressure (BP) in the root of finger, superficial temporal and radial artery based on the volume-compensation technique with reasonable accuracy. The present study concerns with improvement of control method for this beat-by-beat BP measurement. The measurement system mainly consists of a partial pressurization cuff with a pair of LED and photo-diode for the detection of arterial blood volume, and a digital self-tuning control method. Using healthy subjects, the performance and accuracy of this system were evaluated through comparison experiments with the system using a conventional empirically tuned PID controller. The significant differences of BP measured in finger artery were not showed in systolic (SBP), p=0.52, and diastolic BP (DBP), p=0.35. With the advantage of the adaptive control with self-tuning method, which can tune the control parameters without disturbing the control system, the application area of the non-invasive beat-by-beat measurement method will be broadened.

  4. High Blood Pressure (Hypertension) (For Parents)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Hypertension (High Blood Pressure) KidsHealth / For Parents / Hypertension (High Blood Pressure) What's ... High Blood Pressure) Treated? Print What Is Hypertension (High Blood Pressure)? Blood pressure is the pressure of blood against ...

  5. Nocturnal variations in peripheral blood flow, systemic blood pressure, and heart rate in humans

    DEFF Research Database (Denmark)

    Sindrup, J H; Kastrup, J; Christensen, H

    1991-01-01

    Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage uni.......0001). The synchronism of the nocturnal subcutaneous hyperemia and the decrease in systemic mean arterial blood pressure point to a common, possibly central nervous or humoral, eliciting mechanism.......Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage unit...

  6. The EDAPA Project (Education of self-measurement of blood pressure in Grottaglie

    Directory of Open Access Journals (Sweden)

    S. Lenti

    2013-05-01

    Full Text Available AIM OF THE STUDY The EDAPA Project (Education of self-measurement of blood pressure was conceived to train hypertensive patients in self blood pressure monitoring (SBPM and to survey their feedback, including patient’ assessment, by recording their related cardiovascular diseases (CVD risks factors and lifestyle habits. METHODS The project was conducted during the year 2006. Initially we met Grottaglie’s citizens and illustrated to participants the importance of SBPM at home in the overall management of hypertension, that might lead to a better control of BP and cardiovascular outcomes. After explaining the correct technique for SBPM, we distributed semiautomatic devices (OMRON M6 and asked the participants to fill in the Hypertension Questionnaire Form and to record their own blood pressure values in a diary. RESULTS Among almost 3,000 citizens interviewed, 370 (198 M, 172 F; mean age: 60 years agreed to take part in our study. They were hypertensive for almost 10 years, but waited 3 years before beginning therapy. They measured BP 4 times a month and, in the same sitting, 66% of them carried out only 1 measurement, 29% of them 2 measurements and only 2.5% carried out 3 measurements. Taking as reference BP value of 135/85 mmHg, we registered 28% of the population as normotensive and the remaining 72% as hypertensive. Among the hypertensives, 30% showed a good control, 55% showed a bad one and the remaining 15% was not aware of being hypertensive. Adding non-treated hypertensives to those treated but not controlled, we noticed that 70% of the participants was not properly controlled. Regarding risk factors, almost 64% showed hypercholesterolemia; 18% were smokers; 35% of males and 28% of females showed hyperglicemia and 63% of the latter had a waist line > 88 cm; 32% used to consume alcohol (46% males and 15% females; 26% had a metabolic syndrome; 13% was affected by vascular brain injuries, 30% by peripheral artheriopaty, 35% had heart

  7. Gingival blood flow under total combs by functional pressure evaluated with laser-Doppler flowmetry, a non-invasive method of blood flow measurement

    International Nuclear Information System (INIS)

    Hengl, St.

    1996-09-01

    Gingival blood flow under total-combs by functional pressure evaluated with Laser-Doppler Flowmetry, a non-invasive method of blood flow measurement. Microcirculation of gum's capillary system can be measured non-invasive by Laser-Doppler-Flowmetry (LDF). Circulation, defined by the number of floating erythrocytes per unit of time, is measured by a fibro-optical Laser-Doppler-Flowmetry. The task was to examine, if there is any change of gum's circulation during strain and relief. Circulation on defined measurepoints, divided on the four quadrants, was determined among maximal strain and subsequent relief, on one probationer (complete denture bearer). Before every measure session systemic pressure was taken. LDF-value was taken on top of jaw-comb, in doing so, to get reproducible result and a satisfying fixation of the probe, there was made an artificial limb of the upper and lower comb. In the upper comb a dynamometer-box, which determined minimal and maximal comb pressure, was integrated. The received results of the LDF-measurement, expressed as perfusion units (PU) were lower under applied pressure than by pressure points more distant. Hyperemia, resulting during relief, seemed the more intense, the less perfusion was before. This new, non-invasive kind of circulation measurement seems to be quite predestined to be used for gingival diagnostic under artificial limb in the future. (author)

  8. Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized camelids

    OpenAIRE

    Aarnes, Turi K.; Hubbell, John A.E.; Lerche, Phillip; Bednarski, Richard M.

    2012-01-01

    This study assessed the accuracy of the oscillometric method for arterial blood pressure (ABP) monitoring in anesthetized camelids. Twenty camelids were anesthetized and systolic ABP (SABP), mean ABP (MABP), and diastolic ABP (DABP) were measured directly and using the oscillometric method. The mean difference between SABP measurements was −9.9 ± 21.9 mmHg with a range of −76 to 54 mmHg, and the 95% limits of agreement (LOA) were −33 to 53 mmHg. The difference between DABP measurements was −1...

  9. Blood Pressure Medicines

    Science.gov (United States)

    High blood pressure, also called hypertension, usually has no symptoms. But it can cause serious problems such as stroke, heart ... kidney failure. If you cannot control your high blood pressure through lifestyle changes such as losing weight and ...

  10. Blood pressure normalization post-jugular venous balloon angioplasty.

    Science.gov (United States)

    Sternberg, Zohara; Grewal, Prabhjot; Cen, Steven; DeBarge-Igoe, Frances; Yu, Jinhee; Arata, Michael

    2015-05-01

    This study is the first in a series investigating the relationship between autonomic nervous system dysfunction and chronic cerebrospinal venous insufficiency in multiple sclerosis patients. We screened patients for the combined presence of the narrowing of the internal jugular veins and symptoms of autonomic nervous system dysfunction (fatigue, cognitive dysfunction, sleeping disorders, headache, thermal intolerance, bowel/bladder dysfunction) and determined systolic and diastolic blood pressure responses to balloon angioplasty. The criteria for eligibility for balloon angioplasty intervention included ≥ 50% narrowing in one or both internal jugular veins, as determined by the magnetic resonance venography, and ≥ 3 clinical symptoms of autonomic nervous system dysfunction. Blood pressure was measured at baseline and post-balloon angioplasty. Among patients who were screened, 91% were identified as having internal jugular veins narrowing (with obstructing lesions) combined with the presence of three or more symptoms of autonomic nervous system dysfunction. Balloon angioplasty reduced the average systolic and diastolic blood pressure. However, blood pressure categorization showed a biphasic response to balloon angioplasty. The procedure increased blood pressure in multiple sclerosis patients who presented with baseline blood pressure within lower limits of normal ranges (systolic ≤ 105 mmHg, diastolic ≤ 70 mmHg) but decreased blood pressure in patients with baseline blood pressure above normal ranges (systolic ≥ 130 mmHg, diastolic ≥ 80 mmHg). In addition, gender differences in baseline blood pressure subcategories were observed. The coexistence of internal jugular veins narrowing and symptoms of autonomic nervous system dysfunction suggests that the two phenomena may be related. Balloon angioplasty corrects blood pressure deviation in multiple sclerosis patients undergoing internal jugular vein dilation. Further studies should investigate the

  11. [Ambulatory blood pressure monitoring (ABPM) in elderly].

    Science.gov (United States)

    Palade, D; Iliescu, D; Cotârleţ, Laura; Pandele, G I

    2010-01-01

    Comparison of blood pressure values measured by two methods. 94 hypertensive patients (66 women and 28 men in relation to 2.36/1) were assessed classically and also by ABPM. For statistic evaluation we have used t - Student test, chi2 test, Pearson correlation coefficient and variation coefficient (cv%). It shows significant differences between mean values of systolic and diastolic blood pressure obtained by the 2 methods. ABPM measured values are more accurate compared to clinic, bringing also information on pattern hypertensive therapy.

  12. Discarding the first of three nurse-auscultatory or oscillometric blood pressure measurements does not improve the association of office blood pressure with ABPM.

    Science.gov (United States)

    Graves, John W; Grossardt, Brandon R

    2010-06-01

    Guidelines for office blood pressure (BP) measurements recommend two or more readings at each visit. It has been suggested that discarding the first reading may improve the diagnostic utility of office readings. We compare two methods of office BP measurement to determine whether discarding the first BP affects their association with ambulatory blood pressure monitoring (ABPM) readings. We studied measurements in 313 mildly hypertensive patients (181 men, median age 51 years) at the end of the washout phase of a hypertension treatment trial. All patients had three auscultatory readings by a trained nurse using a mercury manometer before a 24-h ABPM and three automated readings (Omron 705 CP) to American Heart Association standards after ABPM. Daytime ABPM (09:00-21:00) of systolic BP and diastolic BP were compared with office methods using first only, second and third only, and all three readings. Associations were assessed using Bland-Altman plots and Pearson's correlations. Bland-Altman plots revealed no differences between office methods and daytime ABPM regardless of whether the first reading was included or discarded. Results were similar for both systolic BP and diastolic BP. The Pearson correlations of office method readings with ABPM readings were lowest using the first measurement alone; however, discarding the first measurement did not improve the correlation compared with using all three readings. Discarding the first office BP reading does not change the association of office BP with ABPM or improve the correlation with ABPM values in hypertensive patients.

  13. Utility of the theory of planned behavior to predict nursing staff blood pressure monitoring behaviours.

    Science.gov (United States)

    Nelson, Joan M; Cook, Paul F; Ingram, Jennifer C

    2014-02-01

    To evaluate constructs from the theory of planned behavior (TPB, Ajzen 2002) - attitudes, sense of control, subjective norms and intentions - as predictors of accuracy in blood pressure monitoring. Despite numerous initiatives aimed at teaching blood pressure measurement techniques, many healthcare providers measure blood pressures incorrectly. Descriptive, cohort design. Medical assistants and licensed practical nurses were asked to complete a questionnaire on TPB variables. These nursing staff's patients had their blood pressures measured and completed a survey about techniques used to measure their blood pressure. We correlated nursing staff's responses on the TBP questionnaire with their intention to measure an accurate blood pressure and with the difference between their actual blood pressure measurement and a second measurement taken by a researcher immediately after the clinic visit. Patients' perceptions of MAs' and LPNs' blood pressure measurement techniques were examined descriptively. Perceived control and social norm predicted intention to measure an accurate blood pressure, with a negative relationship between knowledge and intention. Consistent with the TPB, intention was the only significant predictor of blood pressure measurement accuracy. Theory of planned behavior constructs predicted the healthcare providers' intention to measure blood pressure accurately and intention predicted the actual accuracy of systolic blood pressure measurement. However, participants' knowledge about blood pressure measurement had an unexpected negative relationship with their intentions. These findings have important implications for nursing education departments and organisations which traditionally invest significant time and effort in annual competency training focused on knowledge enhancement by staff. This study suggests that a better strategy might involve efforts to enhance providers' intention to change, particularly by changing social norms or increasing

  14. Radioisotope method for assessing skin blood pressure

    International Nuclear Information System (INIS)

    Tarkowska, A.; Misiunia, P.; Woytowicz, A.; Olewinski, T.

    1979-01-01

    A method of measuring the skin blood pressure (SBP) evolved by Holstein and Lassen is described. The method is based on determination of the force of pressure causing blockade of Na 131 I clearance from the site of its intradermal injection. Using this method it was found that in the lower extremities in healthy subjects the SBP approached the diastolic pressure measured by the conventional method in the brachial artery. On the other hand in patients with obliterative arteriosclerosis and in Buerger's disease the SBP was considerably lower than the diastolic arterial pressure. The authors think that the method gives a good insight into the state of blood supply to the extremities in healthy subjects and in peripheral vascular failure. (author)

  15. Clinical study on influences of enteric coated aspirin on blood pressure and blood pressure variability.

    Science.gov (United States)

    Ji, A-L; Chen, W-W; Huang, W-J

    2016-12-01

    We investigated the effects of oral administration of enteric coated aspirin (ASA) on blood pressure and blood pressure variability of hypertension patients before sleep. We observed 150 hypertension cases, classified as Grade 1-2, from September 2006 to March 2008. They are divided into a control group with 30 cases, ASA I group with 60 cases and ASA II group with 60 cases randomly. Subjects in the control group had proper diets, were losing weight, exercising and maintaining a healthy mentality and were taking 30 mg Adalat orally once a day. Based on the treatment of control group, patients in ASA I group were administered 0.1 g Bayaspirin (produced by Bayer Company) at drought in the morning. Also, based on the treatment of control group, patients in ASA II group were administered 0.1 g Bayaspirin at draught before sleep. The course of treatment is 3 months and then after the treatment, decreasing blood pressure and blood pressure variability conditions in three groups will be compared. Through the comparison of ASA II group with the control group, they have differences in terms of systolic blood pressure (SBP), diastolic blood pressure (DBP), decreasing range of blood pressure and blood pressure variability (p sleep has synergistic effects on decreasing blood pressure of hypertension patients and improving blood pressure variability.

  16. Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure.

    Science.gov (United States)

    Kikuya, Masahiro; Chonan, Kenichi; Imai, Yutaka; Goto, Eiji; Ishii, Masao

    2002-04-01

    Self-measurement of blood pressure (BP) might offer some advantages in diagnosis and therapeutic evaluation and in patient management of hypertension. Recently, wrist-cuff devices for self-measurement of BP have gained more than one-third of the world market share. In the present study, we validated wrist-cuff devices and compared the results between wrist- and arm-cuff devices. The factors affecting the accuracy of wrist-cuff devices were also studied. The research group to assess the validity of automated blood pressure measuring device consisted of 13 institutes in Japan, which validated two wrist-cuff devices (WC-1 and WC-2) and two arm-cuff devices (AC-1 and AC-2). They used a crossover method, where the comparison was done between auscultation, by two observers by means of a double stethoscope on one arm and the device on the opposite arm or wrist. There was good inter-observer agreement for the auscultation method in each institute (systolic blood pressure (SBP), -0.1 +/- 2.8 mmHg; diastolic blood pressure (DBP), -0.1 +/- 2.6 mmHg, n = 498). The mean difference between auscultation and the device was minimal both in arm-cuff devices (mean difference for AC-1, 2.2/1.9 mmHg, n = 97 and for AC-2, 5.1/2.9 mmHg, n = 136, SBP/DBP) and wrist-cuff devices (mean difference for WC-1, -2.1/1.2 mmHg, n = 173 mmHg and for WC-2, -2.3/-5.6 mmHg, n = 92). The standard deviation of the difference (SDD) in wrist-cuff devices, however (SDD for WC-1, 9.7/7.3 mmHg and for WC-2, 10.2/8.6 mmHg), was larger than that of the arm-cuff devices (SDD for AC-1, 5.6/6.6 mmHg and for AC-2, 6.3/5.1 mmHg). Grading of AC-1 and AC-2 based on criteria of British Hypertension Society was A/A and B/A, respectively, while that of WC-1 and WC-2 was C/B and D/B, respectively. Using the same validation protocol, the results of validation for one device were divergent in each institute. In wrist-cuff devices, the BP value obtained in palmar flexion was significantly higher and that obtained in palmar

  17. Dark chocolate and blood pressure: a novel study from Jordan.

    Science.gov (United States)

    Al-Safi, Saafan A; Ayoub, Nehad M; Al-Doghim, Imad; Aboul-Enein, Faisal H

    2011-11-01

    The goal of this study was to assess the effect of dark chocolate intake on cardiovascular parameters like blood pressure and heart rate values in a normotensive population. This is a randomized cross-sectional study involving a total of 14,310 adults that were selected from various regions of Jordan. Well-trained pharmacy students interviewed participants in the outpatient settings. Participants reported their weekly intake of dark chocolate that has been further classified into mild (1-2 bars/week), moderate (3-4 bars/week), and high intake ( > 4 bars/week). For each participant, the systolic blood pressure (SBP), diastolic blood pressure (DBP), and heart rate were measured three times with (10-15) minute intervals in the sitting position and the resting state. The arterial blood pressure (ABP) was calculated from the measured SBP and DBP values. All measured blood pressure values were significantly decreased for participants who reported higher dark chocolate consumption. Our results showed that heart rate values were not affected by variable intake of dark chocolate. In addition, increasing dark chocolate intake was associated with a significant decrease of blood pressure values in participants irrespective of the family history of hypertension or the age of the individual. However, heart rate values were unaffected. Higher intake of dark chocolate can be associated with lower values of blood pressure, while its effect on heart rate values was not consistent.

  18. Elevated preoperative blood pressures in adult surgical patients are highly predictive of elevated home blood pressures.

    Science.gov (United States)

    Schonberger, Robert B; Nwozuzu, Adambeke; Zafar, Jill; Chen, Eric; Kigwana, Simon; Monteiro, Miriam M; Charchaflieh, Jean; Sophanphattana, Sophisa; Dai, Feng; Burg, Matthew M

    2018-04-01

    Blood pressure (BP) measurement during the presurgical assessment has been suggested as a way to improve longitudinal detection and treatment of hypertension. The relationship between BP measured during this assessment and home blood pressure (HBP), a better indicator of hypertension, is unknown. The purpose of the present study was to determine the positive predictive value of presurgical BP for predicting elevated HBP. We prospectively enrolled 200 patients at a presurgical evaluation clinic with clinic blood pressures (CBPs) ≥130/85 mm Hg, as measured using a previously validated automated upper-arm device (Welch Allyn Vital Sign Monitor 6000 Series), to undergo daily HBP monitoring (Omron Model BP742N) between the index clinic visit and their day of surgery. Elevated HBP was defined, per American Heart Association guidelines, as mean systolic HBP ≥135 mm Hg or mean diastolic HBP ≥85 mm Hg. Of the 200 participants, 188 (94%) returned their home blood pressure monitors with valid data. The median number of HBP recordings was 10 (interquartile range, 7-14). Presurgical CBP thresholds of 140/90, 150/95, and 160/100 mm Hg yielded positive predictive values (95% confidence interval) for elevated HBP of 84.1% (0.78-0.89), 87.5% (0.81-0.92), and 94.6% (0.87-0.99), respectively. In contrast, self-reported BP control, antihypertensive treatment, availability of primary care, and preoperative pain scores demonstrated poor agreement with elevated HBP. Elevated preoperative CBP is highly predictive of longitudinally elevated HBP. BP measurement during presurgical assessment may provide a way to improve longitudinal detection and treatment of hypertension. Copyright © 2018 American Heart Association. Published by Elsevier Inc. All rights reserved.

  19. Role of Ambulatory and Home Blood Pressure Monitoring in Clinical Practice: A Narrative Review

    Science.gov (United States)

    Shimbo, Daichi; Abdalla, Marwah; Falzon, Louise; Townsend, Raymond R.; Muntner, Paul

    2015-01-01

    Hypertension, a common cardiovascular disease (CVD) risk factor, is usually diagnosed and treated based on blood pressure readings obtained in the clinic setting. Blood pressure may differ considerably when measured in the clinic versus outside of the clinic setting. Over the past several decades, evidence has accumulated on two approaches for measuring out-of-clinic blood pressure: ambulatory blood pressure monitoring (ABPM) and home blood pressure monitoring (HBPM). Blood pressure measures on ABPM and HBPM each have a stronger association with CVD outcomes than clinic blood pressure. Controversy exists whether ABPM or HBPM is superior for estimating CVD risk, and under what circumstances these methods should be used in clinical practice for assessing out-of-clinic blood pressure. This review describes ABPM and HBPM procedures, the blood pressure phenotypic measures that can be ascertained, and the evidence that supports the use of each approach to measure out-of-clinic blood pressure. This review also describes barriers to the successful implementation of ABPM and HBPM in clinical practice, proposes core competencies for the conduct of these procedures, and highlights important areas for future research. PMID:26457954

  20. A modified isometric test to evaluate blood pressure control with ...

    African Journals Online (AJOL)

    Blood pressure at rest is not predictive of roundthe- clock values. Blood pressure should therefore be measured during effort to evaluate hypertension and its response to treatment. The effect of sustained-release verapamil (240 mg taken once a day) on blood pressure at rest and during isometric effort was therefore ...

  1. Is the area under blood pressure curve the best parameter to evaluate 24-h ambulatory blood pressure monitoring data?

    Science.gov (United States)

    Nobre, Fernando; Mion, Décio

    2005-10-01

    Ambulatory blood pressure monitoring (ABPM) provides relevant data about blood pressure over a 24-h period. The analysis of parameters to determine the blood pressure profile from these data is of great importance. To calculate areas under systolic and diastolic blood pressure curves (SBP-AUC/DBP-AUC) and compare with systolic and diastolic blood pressure load (SBPL/DBPL) and 24-h systolic and diastolic blood pressure (24-h SBP/24-h DBP) in order to determine which provides the best correlation with left ventricular mass index (LVMI). ABPM measurements (1143 individuals) were analyzed to obtain 24-h SBP/24-h DBP, SBPL/DBPL, and SBP-AUC/ DBP-AUC, using Spacelabs (90207) and CardioSistemas devices. Left ventricular mass was determined using an echocardiograph HP Sonos 5500 and LVMI was calculated. The correlations between all possible pairs within the group 24-h SBP/SBPL/SBP-AUC and 24-h DBP/DBPL/DBP-AUC were high and statistically significant. The correlations between 24-h SBP/24-h DBP and SBP-AUC/DBP-AUC with SBPL/DBPL close to 100%, were lower than those mentioned above. The correlations of the parameters obtained by ABPM with LVMI were also high and statistically significant, except for blood pressure load between 90 and 100%, and for 24-h SBP of 135 mmHg or less and SBPL higher than 50%. SBPL/DBPL and SBP-AUC/DBP-AUC can be used for the evaluation of ABPM data owing to the strong correlation with 24-h SBP/24-h DBP and with LVMI, except when SBPL is close to 100% or 24-h SBP is below 135 mmHg but SBPL is above 50%. SBP-AUC/DBP-AUC, however, are a better alternative because they do not have the limitations of blood pressure load or even of 24-h blood pressure present.

  2. Does the Position or Contact Pressure of the Stethoscope Make Any Difference to Clinical Blood Pressure Measurements

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-01-01

    Abstract This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP. PMID:25546675

  3. The distal blood pressure predicts healing of amputations on the feet

    DEFF Research Database (Denmark)

    Holstein, P

    1984-01-01

    The healing of digital and transmetatarsal forefoot amputations was compared with the systolic digital and ankle blood pressure, both measured with a strain-gauge, and with the skin perfusion pressure on the forefoot measured with the isotope washout technique. In 85 out of 134 legs (63 per cent......) the amputation healed. The frequency of healing correlated statistically significantly with all three measures of distal blood pressures, the closest correlation being with the systolic digital blood pressure (SDBP). As measured in 110 cases the healing rates were: SDBP less than 20 mm Hg: four out of 23; SDBP...

  4. A Modern Method to Monitor Office Blood Pressure

    Directory of Open Access Journals (Sweden)

    Emiliya Khazan

    2017-10-01

    Full Text Available The diagnosis and management of hypertension relies on accurate and precise blood pressure (BP measurements and monitoring techniques. Variability in traditional office based BP readings can contribute to misclassification and potential misdiagnosis of hypertension, leading to inappropriate treatment and possibly avoidable adverse drug events. Both home blood pressure monitoring (HBPM and 24-hour ambulatory blood pressure monitoring (ABPM can improve characterization of BP status over traditional office values and can predict cardiovascular morbidity and mortality risk; however, they are limited by availability and/or practical use in many situations. Available in-office blood pressure measuring methods include manual auscultation, automated oscillometric, and automated office blood pressure (AOBP devices. A strong correlation exists between AOBP and awake ABPM measurements and has been linked to better prediction of end-organ damage and white coat response compared to standard office BP methods. While AOBP does not provide nocturnal BP readings, it can be utilized in several outpatient settings, and has the capability to decrease utilization of ABPM, white coat effect, and improve optimization of cardiovascular assessment, evaluation, and therapeutic assessment in clinical practice. Hypertension affects over 80 million adults in the United States (US and is a major risk factor for cardiovascular morbidity and mortality [1]. The condition’s ubiquitous nature and broad impact potentially makes understanding the diagnosis and treatment of hypertension key elements of managing cardiovascular risk. Though much attention is paid to the treatment of hypertension, from 2009 to 2012, 45.9% of US patients with hypertension were uncontrolled [1]. Appreciating the aspects of proper assessment of blood pressure is crucial and creates the foundation for approaching hypertension management. Until recently, hypertension was defined as an appropriately

  5. Ambulatory (24 h) blood pressure and arterial stiffness measurement in Marfan syndrome patients: a case control feasibility and pilot study.

    Science.gov (United States)

    Hillebrand, Matthias; Nouri, Ghazaleh; Hametner, Bernhard; Parragh, Stephanie; Köster, Jelena; Mortensen, Kai; Schwarz, Achim; von Kodolitsch, Yskert; Wassertheurer, Siegfried

    2016-05-06

    The aim of this work is the investigation of measures of ambulatory brachial and aortic blood pressure and indices of arterial stiffness and aortic wave reflection in Marfan patients. A case-control study was conducted including patients with diagnosed Marfan syndrome following Ghent2 nosology and healthy controls matched for sex, age and daytime brachial systolic blood pressure. For each subject a 24 h ambulatory blood pressure and 24 h pulse wave analysis measurement was performed. All parameters showed a circadian pattern whereby pressure dipping was more pronounced in Marfan patients. During daytime only Marfan patients with aortic root surgery showed increased pulse wave velocity. In contrast, various nighttime measurements, wave reflection determinants and circadian patterns showed a significant difference. The findings of our study provide evidence that ambulatory measurement of arterial stiffness parameters is feasible and that these determinants are significantly different in Marfan syndrome patients compared to controls in particular at nighttime. Further investigation is therefore indicated.

  6. Association between routine and standardized blood pressure measurements and left ventricular hypertrophy among patients on hemodialysis.

    Science.gov (United States)

    Khangura, Jaspreet; Culleton, Bruce F; Manns, Braden J; Zhang, Jianguo; Barnieh, Lianne; Walsh, Michael; Klarenbach, Scott W; Tonelli, Marcello; Sarna, Magdalena; Hemmelgarn, Brenda R

    2010-06-24

    Left ventricular (LV) hypertrophy is common among patients on hemodialysis. While a relationship between blood pressure (BP) and LV hypertrophy has been established, it is unclear which BP measurement method is the strongest correlate of LV hypertrophy. We sought to determine agreement between various blood pressure measurement methods, as well as identify which method was the strongest correlate of LV hypertrophy among patients on hemodialysis. This was a post-hoc analysis of data from a randomized controlled trial. We evaluated the agreement between seven BP measurement methods: standardized measurement at baseline; single pre- and post-dialysis, as well as mean intra-dialytic measurement at baseline; and cumulative pre-, intra- and post-dialysis readings (an average of 12 monthly readings based on a single day per month). Agreement was assessed using Lin's concordance correlation coefficient (CCC) and the Bland Altman method. Association between BP measurement method and LV hypertrophy on baseline cardiac MRI was determined using receiver operating characteristic curves and area under the curve (AUC). Agreement between BP measurement methods in the 39 patients on hemodialysis varied considerably, from a CCC of 0.35 to 0.94, with overlapping 95% confidence intervals. Pre-dialysis measurements were the weakest predictors of LV hypertrophy while standardized, post- and inter-dialytic measurements had similar and strong (AUC 0.79 to 0.80) predictive power for LV hypertrophy. A single standardized BP has strong predictive power for LV hypertrophy and performs just as well as more resource intensive cumulative measurements, whereas pre-dialysis blood pressure measurements have the weakest predictive power for LV hypertrophy. Current guidelines, which recommend using pre-dialysis measurements, should be revisited to confirm these results.

  7. Interarm blood pressure difference in people with diabetes: measurement and vascular and mortality implications: a cohort study.

    Science.gov (United States)

    Clark, Christopher E; Steele, Anna M; Taylor, Rod S; Shore, Angela C; Ukoumunne, Obioha C; Campbell, John L

    2014-06-01

    Differences in blood pressure between arms are associated with vascular disease and increased mortality; this has not been reported in diabetes. We explored these associations, and assessed reference standard and pragmatic measurement techniques, in people with diabetes and in nondiabetic controls. A prospective cohort study in Devon, England, recruited 727 people with type 1 or type 2 diabetes and 285 nondiabetic controls. Simultaneous repeated measurements of bilateral blood pressure were made at recruitment. Data were used to inform a pragmatic measurement strategy. Interarm differences were examined for cross-sectional associations with target organ disease and prospective mortality associations (median follow-up 52 months). We found 8.6% of participants with diabetes and 2.9% of controls had systolic interarm differences ≥10 mmHg. Single pairs of blood pressure measurements had high negative predictive values (97-99%) for excluding interarm differences. Systolic interarm differences ≥10 mmHg in diabetes were associated with peripheral arterial disease (odds ratio [OR] 3.4 [95% CI 1.2-9.3]). Differences ≥15 mmHg were associated with diabetic retinopathy (OR 5.7 [1.5-21.6]) and chronic kidney disease (OR 7.0 [1.7-29.8]). Systolic interarm differences were associated prospectively with increased cardiovascular mortality: hazard ratios 3.5 (1.0-13.0) for ≥10 mmHg and 9.0 (2.0-41.0) for ≥15 mmHg. Blood pressure should be measured in both arms during initial assessment in diabetes. Systolic interarm differences can be excluded with a single pair of measurements. In the population with diabetes, systolic differences may be associated with an increased risk of morbidity and mortality. © 2014 by the American Diabetes Association.

  8. Use of Repeated Blood Pressure and Cholesterol Measurements to Improve Cardiovascular Disease Risk Prediction

    DEFF Research Database (Denmark)

    Paige, Ellie; Barrett, Jessica; Pennells, Lisa

    2017-01-01

    The added value of incorporating information from repeated blood pressure and cholesterol measurements to predict cardiovascular disease (CVD) risk has not been rigorously assessed. We used data on 191,445 adults from the Emerging Risk Factors Collaboration (38 cohorts from 17 countries with data...

  9. When tight blood pressure control is not for everyone: a new model for performance measurement in hypertension.

    Science.gov (United States)

    Steinman, Michael A; Goldstein, Mary K

    2010-04-01

    Many patients with hypertension have legitimate reasons to forego standard blood pressure targets yet are nonetheless included in performance measurement systems. An approach to performance measurement incorporating clinical reasoning was developed to determine which patients to include in a performance measure. A 10-member multispecialty advisory panel refined a taxonomy of situations in which the balance of benefits and harms of anti-hypertensive treatment does not clearly favor tight blood pressure control (measurement for blood pressure control. These included (1) patients who have suffered adverse effects from multiple classes of antihypertensive medications; (2) patients already taking four or more antihypertensive medications; (3) patients with terminal disease, moderate to severe dementia, or other conditions that overwhelmingly dominate the patient's clinical status; and (4) other patient factors, including comfort care orientation and poor medication adherence despite attempts to remedy adherence difficulties. Several general principles also emerged. Performance measurement should focus on patients for whom the benefits of treatment clearly outweigh the harms and should incorporate a longitudinal approach. In addition, the criteria for exempting a patient from performance measurement should be more strict in patients at higher risk of adverse health outcomes from hypertension and more lenient for patients at lower risk. Incorporating "real world" clinical principles and judgment into performance measurement systems may improve targeting of care and, by accounting for patient case mix, allow for better comparison of performance between institutions.

  10. Ambulatory Blood Pressure Monitoring: Five Decades of More Light and Less Shadows

    Science.gov (United States)

    Nobre, Fernando; Mion Junior, Décio

    2016-01-01

    Casual blood pressure measurements have been extensively questioned over the last five decades. A significant percentage of patients have different blood pressure readings when examined in the office or outside it. For this reason, a change in the paradigm of the best manner to assess blood pressure has been observed. The method that has been most widely used is the Ambulatory Blood Pressure Monitoring - ABPM. The method allows recording blood pressure measures in 24 hours and evaluating various parameters such as mean BP, pressure loads, areas under the curve, variations between daytime and nighttime, pulse pressure variability etc. Blood pressure measurements obtained by ABPM are better correlated, for example, with the risks of hypertension. The main indications for ABPM are: suspected white coat hypertension and masked hypertension, evaluation of the efficacy of the antihypertensive therapy in 24 hours, and evaluation of symptoms. There is increasing evidence that the use of ABPM has contributed to the assessment of blood pressure behaviors, establishment of diagnoses, prognosis and the efficacy of antihypertensive therapy. There is no doubt that the study of 24-hour blood pressure behavior and its variations by ABPM has brought more light and less darkness to the field, which justifies the title of this review. PMID:27168473

  11. Accuracy of home blood pressure readings: monitors and operators.

    Science.gov (United States)

    Stryker, Trina; Wilson, Merne; Wilson, Thomas W

    2004-06-01

    To evaluate the accuracy of automated digital blood pressure monitoring devices and operators in the community. Also, we tested the effects of a simple education program, and looked for arm-arm differences. Subjects who had bought their own automated digital blood pressure monitor were recruited via an advertisement in the local newspaper. On arrival, they were asked to record their blood pressure exactly as they would at home. The investigator noted any technique deficiencies then corrected them. Blood pressures were then recorded by the investigator and the subject, on opposite arms, simultaneously, and repeated with the arms switched. Finally, subjects recorded their blood pressure again. The subjects' readings were compared to the average of monitor and mercury readings using Bland-Altman methods. A total of 80 subjects were tested. Before educating, subjects' systolic blood pressure (SBP) readings were +5.8+/-6.4 (standard deviation) mmHg greater than the mean of all readings, and diastolic blood pressure (DBP) were +1.3+/-4.0 mmHg; after educating they were +1.3+/-4.0 and -1.3+/-2.7 respectively. The monitors, as a group, were accurate, and met British Hypertension Society and AAMI highest standards. We found no differences among monitors that had been validated (n=26) and those that had not. There were differences between the arms: 5.3+/-5.2 mmHg for SBP and 3.4+/-3.3 mmHg for DBP. Most patients had never been informed by anyone of proper blood pressure measuring techniques. We conclude that home blood pressure measurement, as practiced in our community, is prone to error, mostly due to mistakes by the operator. These can easily be corrected, so that readings become more accurate. Attention should be paid to arm-arm differences.

  12. Blood Pressure Percentiles for School Children

    Directory of Open Access Journals (Sweden)

    İsmail Özanli

    2016-06-01

    Full Text Available Objective: The prevalence of hypertension in childhood and adolescence is gradually increasing. We aimed to in­vestigate the blood pressure (BP values of children aged 7-18 years. Methods: This study was conducted in a total of 3375 (1777 females, 1598 males children from 27 schools. Blood pressures of children were measured using sphyg­momanometer appropriate to arm circumference. Results: A positive relationship was found between sys­tolic blood pressure (SBP and diastolic blood pressure (DBP and the body weight, height, age and body mass index (BMI in male and female children. SBP was high­er in males than females after the age of 13. DBP was higher in males than the females after the age of 14. The mean annual increase of SBP was 2.06 mmHg in males and 1.54 mmHg in females. The mean annual increase of DBP was 1.52 mmHg in males and 1.38 mmHg in fe­males. Conclusion: In this study, we identified the threshold val­ues for blood pressure in children between the age of 7 and 18 years in Erzurum province. It is necessary to com­bine and evaluate data obtained from various regions for the identification of BP percentiles according to the age, gender and height percentiles of Turkish children.

  13. The diagnostic value of supine blood pressure in hypertension.

    Science.gov (United States)

    Krzesiński, Paweł; Stańczyk, Adam; Gielerak, Grzegorz; Piotrowicz, Katarzyna; Banak, Małgorzata; Wójcik, Agnieszka

    2016-04-01

    Correct blood pressure (BP) measurement is crucial in the diagnosis of arterial hypertension (AH), and controversy exists whether supine BP should be treated as equal to sitting BP. The aim of this study was to evaluate the relation of supine BP to sitting BP and ambulatory BP with regard to identification of diagnostic cut-offs for hypertension. This study included 280 patients with AH (mean age: 44.3 ±10.6 years). The following measurements of BP were performed and analyzed: 1) sitting office blood pressure measurement (OSBP and ODBP); 2) supine BP (supSBP and supDBP), measured automatically (5 times with a 2-minute interval) during evaluation by the Niccomo device (Medis, Germany); 3) 24-hour ambulatory blood pressure (ABP) monitoring. The mean supSBP and supDBP were found to be lower than OSBP and ODBP (130.9 ±14.2 vs. 136.6 ±15.5 mm Hg and 84.8 ±9.4 vs. 87.8 ±10.2 mm Hg, respectively; p AUC: 0.820 vs. 0.550; sensitivity 80.7% vs. 57.4%; specificity 83.2% vs. 52.7%; p blood pressure during a 10-minute supine rest was lower than in the sitting position. The supine blood pressure ≥ 130/80 mm Hg was found to be a specific and sensitive threshold for hypertension.

  14. High blood pressure in acute ischemic stroke and clinical outcome.

    Science.gov (United States)

    Manabe, Yasuhiro; Kono, Syoichiro; Tanaka, Tomotaka; Narai, Hisashi; Omori, Nobuhiko

    2009-11-16

    This study aimed to evaluate the prognostic value of acute phase blood pressure in patients with acute ischemic stroke by determining whether or not it contributes to clinical outcome. We studied 515 consecutive patients admitted within the first 48 hours after the onset of ischemic strokes, employing systolic and diastolic blood pressure measurements recorded within 36 hours after admission. High blood pressure was defined when the mean of at least 2 blood pressure measurements was ≥200 mmHg systolic and/or ≥110 mmHg diastolic at 6 to 24 hours after admission or ≥180 mmHg systolic and/or ≥105 mmHg diastolic at 24 to 36 hours after admission. The high blood pressure group was found to include 16% of the patients. Age, sex, diabetes mellitus, hypercholesterolemia, atrial fibrillation, ischemic heart disease, stroke history, carotid artery stenosis, leukoaraiosis, NIH Stroke Scale (NIHSS) on admission and mortality were not significantly correlated with either the high blood pressure or non-high blood pressure group. High blood pressure on admission was significantly associated with a past history of hypertension, kidney disease, the modified Rankin Scale (mRS) on discharge and the length of stay. On logistic regression analysis, with no previous history of hypertension, diabetes mellitus, atrial fibrillation, and kidney disease were independent risk factors associated with the presence of high blood pressure [odds ratio (OR), 1.85 (95% confidence interval (CI): 1.06-3.22), 1.89 (95% CI: 1.11-3.22), and 3.31 (95% CI: 1.36-8.04), respectively]. Multi-organ injury may be presented in acute stroke patients with high blood pressure. Patients with high blood pressure had a poor functional outcome after acute ischemic stroke.

  15. From pioneering to implementing automated blood pressure measurement in clinical practice: Thomas Pickering's legacy

    DEFF Research Database (Denmark)

    Stolarz-Skrzypek, Katarzyna; Thijs, Lutgarde; Wizner, Barbara

    2010-01-01

    Thomas G. Pickering spent most of his scientific career in carrying out research on clinical hypertension and blood pressure (BP) measurement. In our review of Pickering's seminal work, we first focused on white-coat hypertension and masked hypertension, two terms that he had introduced. Next, we...

  16. Measurement of blood pressure for the diagnosis and management of hypertension in different ethnic groups: one size fits all.

    Science.gov (United States)

    Gill, Paramjit; Haque, M Sayeed; Martin, Una; Mant, Jonathan; Mohammed, Mohammed A; Heer, Gurdip; Johal, Amanpreet; Kaur, Ramandeep; Schwartz, Claire; Wood, Sally; Greenfield, Sheila M; McManus, Richard J

    2017-02-08

    Hypertension is a major risk factor for cardiovascular disease and prevalence varies by ethnic group. The diagnosis and management of blood pressure are informed by guidelines largely based on data from white populations. This study addressed whether accuracy of blood pressure measurement in terms of diagnosis of hypertension varies by ethnicity by comparing two measurement modalities (clinic blood pressure and home monitoring) with a reference standard of ambulatory BP monitoring in three ethnic groups. Cross-sectional population study (June 2010 - December 2012) with patients (40-75 years) of white British, South Asian and African Caribbean background with and without a previous diagnosis of hypertension recruited from 28 primary care practices. The study compared the test performance of clinic BP (using various protocols) and home-monitoring (1 week) with a reference standard of mean daytime ambulatory measurements using a threshold of 140/90 mmHg for clinic and 135/85 mmHg for out of office measurement. A total of 551 participants had complete data of whom 246 were white British, 147 South Asian and 158 African Caribbean. No consistent difference in accuracy of methods of blood pressure measurement was observed between ethnic groups with or without a prior diagnosis of hypertension: for people without hypertension, clinic measurement using three different methodologies had high specificity (75-97%) but variable sensitivity (33-65%) whereas home monitoring had sensitivity of 68-88% and specificity of 64-80%. For people with hypertension, detection of a raised blood pressure using clinic measurements had sensitivities of 34-69% with specificity of 73-92% and home monitoring had sensitivity (81-88%) and specificity (55-65%). For people without hypertension, ABPM remains the choice for diagnosing hypertension compared to the other modes of BP measurement regardless of ethnicity. Differences in accuracy of home monitoring and clinic monitoring (higher sensitivity

  17. Types of Blood Pressure Medications

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Types of Blood Pressure Medications Updated:Nov 6,2017 Prescription blood pressure ... This content was last reviewed October 2017. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  18. Controlling your high blood pressure

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000101.htm Controlling your high blood pressure To use the sharing features on this page, ... JavaScript. Hypertension is another term used to describe high blood pressure. High blood pressure can lead to: Stroke Heart ...

  19. A pitfall in the measurement of arterial blood pressure in the ischaemic limb during elevation

    DEFF Research Database (Denmark)

    Bülow, J; Jelnes, Rolf

    1987-01-01

    In order to evaluate if elevation of the ischaemic limb above heart level is an alternative to the conventionally applied method with external counterpressure for estimation of skin perfusion pressure, femoral and popliteal artery pressures were measured directly in eight patients with occlusion...... of the superficial femoral artery. The measurements were done in the horizontal position and during elevation of the calf above heart level. During elevation relative blood flow, measured by arterio-venous oxygen saturation differences, decreased compared with the horizontal position. In contrast the popliteal...... arterial pressure decreased only by 20% of the value expected from the degree of elevation of the calf above the level of the heart. Thus, it could be calculated that calf vascular resistance increased two- to three-fold on average during elevation. Four patients were reexamined with the venous pressure...

  20. Validation of the HONSUN LD-578 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol.

    Science.gov (United States)

    Zhang, Yi; Wang, Jie; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2009-06-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor LD-578 (HONSUN Group, Shanghai, China) for home blood pressure monitoring according to the International Protocol. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese using a mercury sphygmomanometer (two observers) and the LD-578 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was performed using the ESHIP Analyzer. The LD-578 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 32 of 45, 41 of 45, and 45 of 45 measurements (required 25, 35, and 40), respectively. The device also achieved the targets for phase 2.1, with 67 of 99, 90 of 99, and 98 of 99 differences within 5, 10, and 15 mmHg, respectively, for systolic blood pressure, and with 69 of 99, 95 of 99, and 98 of 99 within 5, 10, and 15 mmHg, respectively, for diastolic blood pressure. In phase 2.2, 24 participants had at least two of the three device-observers differences within 5 mmHg (required >or=22) for systolic and diastolic blood pressure. The HONSUN upper arm blood pressure monitor LD-578 can be recommended for home use in adults.

  1. Association of betaine with blood pressure in dialysis patients.

    Science.gov (United States)

    Wang, Lulu; Zhao, Mingming; Liu, Wenjin; Li, Xiurong; Chu, Hong; Bai, Youwei; Sun, Zhuxing; Gao, Chaoqing; Zheng, Lemin; Yang, Junwei

    2018-02-01

    Mechanisms underlying elevated blood pressure in dialysis patients are complex as a variety of non-traditional factors are involved. We sought to explore the association of circulating betaine, a compound widely distributed in food, with blood pressure in dialysis patients. We used baseline data of an ongoing cohort study involving patients on hemodialysis. Plasma betaine was measured by high performance liquid chromatography in 327 subjects. Blood pressure level was determined by intradialytic ambulatory blood pressure monitoring. The mean age of the patients was 52.6 ± 11.9 years, and 58.4% were male. Average interdialytic ambulatory systolic and diastolic blood pressure were 138.4 ± 22.7 mm Hg and 84.4 ± 12.5 mm Hg, respectively. Mean plasma betaine level was 37.6 μmol/L. Multiple linear regression analysis revealed significant associations of betaine with both systolic blood pressure (β = -3.66, P = .003) and diastolic blood pressure (β = -2.00, P = .004). The associations persisted even after extensive adjustment for cardiovascular covariates. Subgroup analysis revealed that the association between betaine and blood pressure was mainly limited to female patients. Our data suggest that alteration of circulating betaine possibly contributes to blood pressure regulation in these patients. ©2018 Wiley Periodicals, Inc.

  2. Cuffless differential blood pressure estimation using smart phones.

    Science.gov (United States)

    Chandrasekaran, Vikram; Dantu, Ram; Jonnada, Srikanth; Thiyagaraja, Shanti; Subbu, Kalyan Pathapati

    2013-04-01

    Smart phones today have become increasingly popular with the general public for their diverse functionalities such as navigation, social networking, and multimedia facilities. These phones are equipped with high-end processors, high-resolution cameras, and built-in sensors such as accelerometer, orientation-sensor, and light-sensor. According to comScore survey, 26.2% of U.S. adults use smart phones in their daily lives. Motivated by this statistic and the diverse capability of smart phones, we focus on utilizing them for biomedical applications. We present a new application of the smart phone with its built-in camera and microphone replacing the traditional stethoscope and cuff-based measurement technique, to quantify vital signs such as heart rate and blood pressure. We propose two differential blood pressure estimating techniques using the heartbeat and pulse data. The first method uses two smart phones whereas the second method replaces one of the phones with a customized external microphone. We estimate the systolic and diastolic pressure in the two techniques by computing the pulse pressure and the stroke volume from the data recorded. By comparing the estimated blood pressure values with those measured using a commercial blood pressure meter, we obtained encouraging results of 95-100% accuracy.

  3. Association between routine and standardized blood pressure measurements and left ventricular hypertrophy among patients on hemodialysis

    Directory of Open Access Journals (Sweden)

    Walsh Michael

    2010-06-01

    Full Text Available Abstract Background Left ventricular (LV hypertrophy is common among patients on hemodialysis. While a relationship between blood pressure (BP and LV hypertrophy has been established, it is unclear which BP measurement method is the strongest correlate of LV hypertrophy. We sought to determine agreement between various blood pressure measurement methods, as well as identify which method was the strongest correlate of LV hypertrophy among patients on hemodialysis. Methods This was a post-hoc analysis of data from a randomized controlled trial. We evaluated the agreement between seven BP measurement methods: standardized measurement at baseline; single pre- and post-dialysis, as well as mean intra-dialytic measurement at baseline; and cumulative pre-, intra- and post-dialysis readings (an average of 12 monthly readings based on a single day per month. Agreement was assessed using Lin's concordance correlation coefficient (CCC and the Bland Altman method. Association between BP measurement method and LV hypertrophy on baseline cardiac MRI was determined using receiver operating characteristic curves and area under the curve (AUC. Results Agreement between BP measurement methods in the 39 patients on hemodialysis varied considerably, from a CCC of 0.35 to 0.94, with overlapping 95% confidence intervals. Pre-dialysis measurements were the weakest predictors of LV hypertrophy while standardized, post- and inter-dialytic measurements had similar and strong (AUC 0.79 to 0.80 predictive power for LV hypertrophy. Conclusions A single standardized BP has strong predictive power for LV hypertrophy and performs just as well as more resource intensive cumulative measurements, whereas pre-dialysis blood pressure measurements have the weakest predictive power for LV hypertrophy. Current guidelines, which recommend using pre-dialysis measurements, should be revisited to confirm these results.

  4. Acute effects of consumption of energy drinks on intraocular pressure and blood pressure

    Directory of Open Access Journals (Sweden)

    Ilechie AA

    2011-04-01

    Full Text Available A Alex Ilechie, Sandra TettehDepartment of Optometry, University of Cape Coast, GhanaBackground: Energy drinks contain a wide variety of ingredients including caffeine, for which there have been conflicting reports regarding its effects on intraocular pressure (IOP and blood pressure. The aim of this study was to investigate the acute effects of an energy drink (Red Bull® on the IOP and blood pressure of healthy young adults.Methods: Thirty healthy university students of either gender, aged 18–30 (mean 23.20 ± 2.81 years were randomly selected to participate in this study. The subjects were randomly divided into two groups (experimental and control and were asked to abstain from caffeine for 48 hours prior to and during the study. Baseline IOP and blood pressure were measured. The experimental group (n = 15 consumed one can of the energy drink (containing 85 mg of caffeine in 250 mL and measurements were repeated at 30, 60, and 90 minutes, while the control group drank 250 mL of water and were tested over the same time period.Results: When compared with baseline, a significant decrease (P < 0.05 in mean IOP at 60 and 90 minutes was observed in the experimental group. There was no corresponding change in systolic or diastolic blood pressure.Conclusion: Our results suggest that energy drinks (ie, Red Bull produce a significant reduction in IOP but have no effect on blood pressure. These findings may be interpreted as reflecting the effect of the combination of caffeine and taurine in the Red Bull energy drink. This effect may result from the known hypotensive effect of taurine, and warrants further study.Keywords: acute effect, intraocular pressure, blood pressure, glaucoma, caffeine, taurine

  5. Heritability of blood pressure traits and the genetic contribution to blood pressure variance explained by four blood-pressure-related genes.

    NARCIS (Netherlands)

    Rijn, M.J. van; Schut, A.F.; Aulchenko, Y.S.; Deinum, J.; Sayed-Tabatabaei, F.A.; Yazdanpanah, M.; Isaacs, A.; Axenovich, T.I.; Zorkoltseva, I.V.; Zillikens, M.C.; Pols, H.A.; Witteman, J.C.; Oostra, B.A.; Duijn, C.M. van

    2007-01-01

    OBJECTIVE: To study the heritability of four blood pressure traits and the proportion of variance explained by four blood-pressure-related genes. METHODS: All participants are members of an extended pedigree from a Dutch genetically isolated population. Heritability and genetic correlations of

  6. Prevalence of end-digit preference in recorded blood pressure by ...

    African Journals Online (AJOL)

    2012-03-15

    Mar 15, 2012 ... (BP) measuring device eliminates the risk of exposure to mercury. ... Results: There was a large and significant fall in end-digit zero when BP readings that were ..... positioning, an inadequate rest period and the posture of the .... electronic blood pressure measurement influence recorded blood pressure?

  7. The impact of arm circumference on noninvasive oscillometric blood pressure referenced with intra-aortic blood pressure.

    Science.gov (United States)

    Shangguan, Qing; Wu, Yanqing; Xu, Jinsong; Su, Hai; Li, Juxiang; Hong, Kui; Cheng, Xiaoshu

    2015-12-01

    To investigate the influence of arm circumference (AC) on the brachial blood pressure (BP) measured with an adult cuff. This study included 208 patients (150 men, 61.0±8.0 years) for coronary angiography. Intra-aortic BP and noninvasive right brachial oscillometric BP (noninvasive BP) were measured simultaneously before coronary angiography. The noninvasive BP was measured using an electronic oscillometric device with an adult cuff (12×22 cm). The mid-ACs were measured. Thus, proper cuff-arm (≤26 cm) and small cuff (>26 cm) groups were created. The difference in intra-aortic and noninvasive BP was calculated as BPi-n. The correlation coefficients (r) between noninvasive and invasive systolic blood pressure (SBP), mean artery pressure, and diastolic blood pressure (DBP) were 0.88, 0.76, and 0.58, respectively. The SBPi-n was higher (7.9±1.6 vs. 5.2±1.1 mmHg), but the DBPi-n (3.9±1.4 vs. 6.1±1.0 mmHg, P26 cm. Among the four subgroups divided by 20-23, 24-26, 27-30, and 31-37 cm of AC, as the AC increased, the SBPi-n increased, but DBP decreased, resulting in noninvasive SBP 4.6 mmHg higher and noninvasive DBP 4.6 mmHg lower in the 31-37 cm group in comparison with the 20-23 cm group. When an adult cuff was used, the noninvasive oscillometric SBP was overestimated, but DBP was underestimated in the individuals with large arms against the intra-aortic BP.

  8. Could self-measured office blood pressure be a hypertension screening tool for limited-resources settings?

    Science.gov (United States)

    Salazar, Martin R; Espeche, Walter G; Stavile, Rodolfo N; Balbín, Eduardo; Leiva Sisnieguez, Betty C; Leiva Sisnieguez, Carlos E; March, Carlos E; Cor, Susana; Eugenio Acero, Irma; Carbajal, Horacio A

    2018-05-01

    Blood pressure (BP) was assessed by patients themselves in recently published trials. Self-measured office blood pressure (SMOBP) seems particularly interesting for limited health resources regions. The aim of our study was to evaluate the relationship between SMOBP values and those estimated by ambulatory blood pressure monitoring (ABPM). Six hundred seventy-seven patients were evaluated using both, SMOBP and ABPM. The differences between SMOBP and daytime ABPM were evaluated with paired "t" test. The correlations among SMOBP and ABPM were estimated using Pearson's r. The accuracy of SMOBP to identify abnormal ABPM was determined using area under ROC curve (AUC). Sensitivity, specificity, and positive and negative predictive values were calculated for different SMOBP cut-points. Using the average of three readings, systolic SMOBP was higher (3.7 (14.2) mmHg, p 95%) to identify individuals with hypertension in the ABPM; SMOBP < 130/80 mmHg reasonably discarded abnormal ABPM. In conclusion, a high proportion of individuals could be classified adequately using SMOBP, reducing the necessity of healthcare resources and supporting its utility for screening purposes.

  9. Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Zhang, Lu; Kang, Yuan-Yuan; Zeng, Wei-Fang; Li, Yan; Wang, Ji-Guang

    2015-04-01

    The present study aimed to evaluate the accuracy of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (17 women, mean age 46 years) using a mercury sphygmomanometer (two observers) and the Rossmax CF175 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The Rossmax CF175 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 78/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 81/99, 96/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-nine participants, for both of systolic and diastolic blood pressure, had at least two of the three device-observers differences within 5 mmHg (required ≥24). Only one participant for diastolic blood pressure had all three device-observers comparisons greater than 5 mmHg. The Rossmax automated oscillometric upper-arm blood pressure monitor CF175 fulfilled the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  10. Non-invasive pulmonary blood flow analysis and blood pressure mapping derived from 4D flow MRI

    Science.gov (United States)

    Delles, Michael; Rengier, Fabian; Azad, Yoo-Jin; Bodenstedt, Sebastian; von Tengg-Kobligk, Hendrik; Ley, Sebastian; Unterhinninghofen, Roland; Kauczor, Hans-Ulrich; Dillmann, Rüdiger

    2015-03-01

    In diagnostics and therapy control of cardiovascular diseases, detailed knowledge about the patient-specific behavior of blood flow and pressure can be essential. The only method capable of measuring complete time-resolved three-dimensional vector fields of the blood flow velocities is velocity-encoded magnetic resonance imaging (MRI), often denoted as 4D flow MRI. Furthermore, relative pressure maps can be computed from this data source, as presented by different groups in recent years. Hence, analysis of blood flow and pressure using 4D flow MRI can be a valuable technique in management of cardiovascular diseases. In order to perform these tasks, all necessary steps in the corresponding process chain can be carried out in our in-house developed software framework MEDIFRAME. In this article, we apply MEDIFRAME for a study of hemodynamics in the pulmonary arteries of five healthy volunteers. The study included measuring vector fields of blood flow velocities by phase-contrast MRI and subsequently computing relative blood pressure maps. We visualized blood flow by streamline depictions and computed characteristic values for the left and the right pulmonary artery (LPA and RPA). In all volunteers, we observed a lower amount of blood flow in the LPA compared to the RPA. Furthermore, we visualized blood pressure maps using volume rendering and generated graphs of pressure differences between the LPA, the RPA and the main pulmonary artery. In most volunteers, blood pressure was increased near to the bifurcation and in the proximal LPA, leading to higher average pressure values in the LPA compared to the RPA.

  11. Validation of the Kingyield BP210 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension-International Protocol.

    Science.gov (United States)

    Zeng, Wei-Fang; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2012-02-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor BP210 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese participants (21 women, 51 years of mean age) using a mercury sphygmomanometer (two observers) and the BP210 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was conducted using the ESHIP analyzer. The BP210 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 33/45, 44/45, and 44/45 measurements, respectively. The device also achieved the targets for phase 2.1, with 77/99, 95/99, and 97/99 differences within 5, 10, and 15 mmHg, respectively for systolic blood pressure, and with 78/99, 97/99, and 99/99 within 5, 10, and 15 mmHg, respectively for diastolic blood pressure. In phase 2.2, 29 and 25 participants had at least two of the three device-observers differences within 5 mmHg (required≥22) for systolic blood pressure and diastolic blood pressure, respectively. The Kingyield wrist blood pressure monitor BP210 has passed the International Protocol requirements, and hence can be recommended for home use in adults.

  12. Office blood pressure measurement alone often misclassifies treatment status in children with primary hypertension.

    Science.gov (United States)

    Samuel, Joyce P; Bell, Cynthia S; Hebert, Sean A; Varughese, Arun; Samuels, Joshua A; Tyson, Jon E

    2017-12-01

    Clinicians frequently rely on office blood pressure (BP) measurements alone to assess hypertension control, despite widespread acceptance of 24-h ambulatory blood pressure monitoring (ABPM) as the reference standard in the initial diagnosis of hypertension. This study was designed to investigate how often the hypertensive status differed between concurrent office BP versus ABPM measurements, and whether any patient-specific characteristics predict the risk for misclassification by office BP. This study evaluated 42 children with primary hypertension who underwent repeated ambulatory monitoring (190 total recordings) with concurrent office BP measurement as part of their participation in n-of-1 trials. In nearly 40% of the visits, the treatment status by office measurement was opposite to the status by ambulatory monitoring. Office BP underestimated the ambulatory hypertensive status (masked uncontrolled hypertension) in 25% of visits and overestimated ambulatory BP (white coat effect) in 14% of visits. The difference between office BP and ambulatory monitoring was consistent within patients across repeated visits. Patients whose office measurement underestimated or overestimated the ambulatory BP at the first visit were more likely to show persistent discrepancy at subsequent visits. The underuse of ambulatory monitoring in management decisions of children treated for primary hypertension may result in systematic misclassification of hypertension control.

  13. Serotonin and Blood Pressure Regulation

    Science.gov (United States)

    Morrison, Shaun F.; Davis, Robert Patrick; Barman, Susan M.

    2012-01-01

    5-Hydroxytryptamine (5-HT; serotonin) was discovered more than 60 years ago as a substance isolated from blood. The neural effects of 5-HT have been well investigated and understood, thanks in part to the pharmacological tools available to dissect the serotonergic system and the development of the frequently prescribed selective serotonin-reuptake inhibitors. By contrast, our understanding of the role of 5-HT in the control and modification of blood pressure pales in comparison. Here we focus on the role of 5-HT in systemic blood pressure control. This review provides an in-depth study of the function and pharmacology of 5-HT in those tissues that can modify blood pressure (blood, vasculature, heart, adrenal gland, kidney, brain), with a focus on the autonomic nervous system that includes mechanisms of action and pharmacology of 5-HT within each system. We compare the change in blood pressure produced in different species by short- and long-term administration of 5-HT or selective serotonin receptor agonists. To further our understanding of the mechanisms through which 5-HT modifies blood pressure, we also describe the blood pressure effects of commonly used drugs that modify the actions of 5-HT. The pharmacology and physiological actions of 5-HT in modifying blood pressure are important, given its involvement in circulatory shock, orthostatic hypotension, serotonin syndrome and hypertension. PMID:22407614

  14. Orthostatic circulatory control in the elderly evaluated by non-invasive continuous blood pressure measurement

    NARCIS (Netherlands)

    Imholz, B. P.; Dambrink, J. H.; Karemaker, J. M.; Wieling, W.

    1990-01-01

    1. Continuous orthostatic responses of blood pressure and heart rate were measured in 40 healthy and active elderly subjects over 70 years of age in order to assess the time course and rapidity of orthostatic cardiovascular adaptation in old age. 2. During the first 30 s (initial phase) the effects

  15. Measurement of bone blood flow in sheep

    International Nuclear Information System (INIS)

    Rosenthal, M.S.; Lehner, C.E.; Pearson, D.W.; Kanikula, T.; Adler, G.; Venci, R.; Lanphier, E.H.; DeLuca, P.M. Jr.

    1984-01-01

    Bone blood flow in sheep tibia has been estimated via the measurement of the perfusion limited clearance of 41 Ar from the bone mineral matrix following fast neutron activation of 44 Ca. Tibia blood flows were estimated for the intact sheep, and after the installation of an intramedullary pressure tap to elevate bone marrow pressure by saline infusion. The results indicate that normal blood flow in the tibia is in the range of 1.1 to 3.7 ml/100ml-min in the intact animal and at normal marrow pressure. With an elevated intramedullary pressure of approximately 100 mmHg, the bone blood flow measured varied around 0.5 to 1.1 ml/100ml-min. 12 refs., 5 figs., 1 tab

  16. Effects of Malaria on Blood Pressure, Heart Rate, Electrocardiogram ...

    African Journals Online (AJOL)

    The effect of malaria on blood pressure, heart rate, electrocardiogram and the cardiovascular responses to postural change were studied in malaria patients. Blood pressure was measured by the sphygmomanometric-auscultatory method. Standard ECG machine was used to record the electrocardiogram. Heart rate was ...

  17. Mid-regional pro-atrial natriuretic peptide and blood pressure in adolescents

    DEFF Research Database (Denmark)

    Goharian, Tina S; Gimsing, Anders N; Goetze, Jens P

    2015-01-01

    Little is known about blood pressure in relation to circulating natriuretic peptide concentrations and gender in generally healthy adolescents. We studied 15-year-old females and males (n = 335) from the Danish site of the European Youth Heart Study (EYHS). Blood pressure was measured using...... a standardized protocol, sexual maturity was assessed according to Tanner stage, and as a surrogate for atrial natriuretic peptide, we measured mid-regional pro-atrial natriuretic peptide (MR-proANP) in plasma. Compared with boys, girls had lower systolic blood pressure (SBP) (mean ± SD: 109.6 ± 9.9 mmHg vs 116.......9 ± 11.4 mmHg, p blood pressure...

  18. Occlusion cuff for routine measurement of digital blood pressure and blood flow

    DEFF Research Database (Denmark)

    Lassen, N A; Krähenbühl, B; Hirai, M

    1977-01-01

    A miniaturized blood pressure cuff made of plastic material and applicable to fingers and toes is described. The cuff was compared to rubber cuffs and to bladder-free cuffs. It was found to be more reliable than the former type and much easier to use than the latter type. It is recommended for us...

  19. Studies Comparing Ambulatory Blood Pressure and Home Blood Pressure on Cardiovascular Disease and Mortality Outcomes: A Systematic Review

    Science.gov (United States)

    Shimbo, Daichi; Abdalla, Marwah; Falzon, Louise; Townsend, Raymond R.; Muntner, Paul

    2015-01-01

    Ambulatory blood pressure monitoring (ABPM) is more commonly recommended for assessing out-of-clinic blood pressure than home blood pressure monitoring (HBPM). We conducted a systematic review to examine whether ABPM or HBPM is more strongly associated with cardiovascular disease events and/or mortality. Of 1,007 abstracts published through July 20, 2015, nine articles, reporting results from seven cohorts, were identified. After adjustment for blood pressure on HBPM, blood pressure on ABPM was associated with an increased risk of outcomes in two of four cohorts for systolic blood pressure and two of three cohorts for diastolic blood pressure. After adjustment for blood pressure on ABPM, systolic blood pressure on HBPM was associated with outcomes in zero of three cohorts; an association was present in one of two cohorts for diastolic blood pressure on HBPM. There is a lack of strong empiric evidence supporting ABPM or HBPM over the other approach for predicting cardiovascular events or mortality. PMID:26822864

  20. A Study on Anthropometric Measurements, Blood Pressure, Blood Sugar and Food Intakes Among Different Social Status and Ethnicities

    Directory of Open Access Journals (Sweden)

    Jafarirad

    2016-09-01

    Full Text Available Background Metabolic syndrome is a disorder that increases the risk of cardiovascular disease and diabetes. Objectives The aim of the study was to evaluate some risk factors of the metabolic syndrome and food intakes among people who lived in Ahvaz City, Iran. Methods It was a filed study that was conducted on 211 subjects who participated in health exhibition. Socioeconomic status and ethnicity were asked by a general questionnaire. Weight, height, body mass index, waist circumference (WC and WC to hip circumference ratio (WHR were obtained. Blood sugar was measured by a glucometer. Systolic and diastolic blood pressures were obtained and dietary intakes were assessed by a brief instrument. Results There was a significant difference in weight, height, WC, WHR and systolic blood pressure among different jobs. Workers had more intakes of cake and sweets. Arab subjects had more intakes of bread and fishes and Persians more intakes of vegetables. Soda, chocolate and candy were more consumed by Kurd ethnicity. Conclusions Job may be accounted as an important effective socioeconomic factor related to metabolic syndrome risk factors; also different cultures due to different ethnicities may have an influence on lifestyle and dietary intakes.

  1. Prognostic value of blood pressure measured during hospitalization after acute myocardial infarction: an insight from survival trials

    DEFF Research Database (Denmark)

    Yap, Yee Guan; Duong, Trinh; Bland, J Martin

    2007-01-01

    , CAMIAT, SWORD, TRACE and DIAMOND-MI studies with left ventricular ejection fraction less than 40% or asymptomatic ventricular arrhythmia surviving more than 45 days after MI were pooled. Systolic and diastolic blood pressures and pulse pressures were measured soon after MI (median 6 days, range 0-53 days...

  2. Effects of endurance training on blood pressure, blood pressure-regulating mechanisms, and cardiovascular risk factors.

    Science.gov (United States)

    Cornelissen, Véronique A; Fagard, Robert H

    2005-10-01

    Previous meta-analyses of randomized controlled trials on the effects of chronic dynamic aerobic endurance training on blood pressure reported on resting blood pressure only. Our aim was to perform a comprehensive meta-analysis including resting and ambulatory blood pressure, blood pressure-regulating mechanisms, and concomitant cardiovascular risk factors. Inclusion criteria of studies were: random allocation to intervention and control; endurance training as the sole intervention; inclusion of healthy sedentary normotensive or hypertensive adults; intervention duration of > or =4 weeks; availability of systolic or diastolic blood pressure; and publication in a peer-reviewed journal up to December 2003. The meta-analysis involved 72 trials, 105 study groups, and 3936 participants. After weighting for the number of trained participants and using a random-effects model, training induced significant net reductions of resting and daytime ambulatory blood pressure of, respectively, 3.0/2.4 mm Hg (Phypertensive study groups (-6.9/-4.9) than in the others (-1.9/-1.6; Pendurance training decreases blood pressure through a reduction of vascular resistance, in which the sympathetic nervous system and the renin-angiotensin system appear to be involved, and favorably affects concomitant cardiovascular risk factors.

  3. High blood pressure - children

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007696.htm High blood pressure - children To use the sharing features on this page, please enable JavaScript. High blood pressure (hypertension) is an increase in the force of ...

  4. High blood pressure - infants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007329.htm High blood pressure - infants To use the sharing features on this page, please enable JavaScript. High blood pressure (hypertension) is an increase in the force of ...

  5. High blood pressure medications

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007484.htm High blood pressure medicines To use the sharing features on this page, please enable JavaScript. Treating high blood pressure will help prevent problems such as heart disease, ...

  6. Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Huang, Jinhua; Li, Zhijie; Li, Guimei; Liu, Zhaoying

    2015-10-01

    This study aimed to evaluate the accuracy of the Andon KD-5965 upper-arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults, with 20 women using a mercury sphygmomanometer (two observers) and the Andon KD-5965 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 70/99, 91/99, and 98/99, respectively, for systolic blood pressure and 81/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-five and 29 participants, for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required≥24). Two and one participants for systolic and diastolic blood pressure, respectively, had all three device-observers comparisons greater than 5 mmHg. According to the validation results, with better performance for diastolic blood pressure than that for systolic blood pressure, the Andon automated oscillometric upper-arm blood pressure monitor KD-5965 fulfilled the requirements of the European Society of Hypertension International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  7. Simultaneous blood pressure measurement in both arms in hypertensive and nonhypertensive adult patients.

    Science.gov (United States)

    Fonseca-Reyes, Salvador; Forsyth-MacQuarrie, Avril M; García de Alba-García, Javier Eduardo

    2012-08-01

    When blood pressure (BP) is taken for the first time, it should be measured in both arms; follow-up measurements should be taken in the arm with the highest BP. However, in clinical practice, this recommendation is rarely followed. Identify the degree of differences in BP between the right and the left arm in individuals with normal and high BP. We measured BP in 111 hypertensive and 80 normotensive patients in both arms at the same time using identical Omron HEM 725 CIC automatic sphygmomanometers. The devices were then switched to the other arm and another set of readings was taken. The absolute and relative difference in BP between arms was calculated from the average of these two readings. We categorized differences as at least 5, at least 10, and at least 20 mmHg for systolic blood pressure/diastolic blood pressure (SBP/DBP). The BP was higher in the right arm, with no statistical significance. The relative differences were also not significant: SBP 1.1±7.1 and DBP 0.21±5.0. However, the absolute differences were significant at an individual level, with a systolic difference of 5.4±4.8 mmHg and a diastolic difference of 3.9 ±3.2 mmHg. The percentages of absolute SBP/DBP differences more than 5 mmHg (21.4%/20.4%) and more than 10 mmHg (15.7%/4.7%) were considerable. The range of arm differences was clinically significant; in hypertensives, the SBP/DBP was -13.2 to +15/-9.2 to +9.6 mmHg and in nonhypertensives it was -12.9 to +15.6/-9.7 to +10.1 mmHg. Although on average there was no clinically significant relative difference between arms, absolute differences at an individual level were often clinically significant. Failure to determine interarm BP differences will lead to erroneous clinical decisions.

  8. Blood pressure and pain sensitivity in children and adolescents.

    Science.gov (United States)

    Drouin, Sammantha; McGrath, Jennifer J

    2013-06-01

    Elevated blood pressure is associated with diminished pain sensitivity. While this finding is well established in adults, it is less clear when the relation between blood pressure and pain sensitivity emerges across the life course. Evidence suggests this phenomenon may exist during childhood. Children (N = 309; 56% boys) aged 10-15 years and their parents participated. Blood pressure readings were taken during a resting baseline. Maximum pain intensity was rated using a visual analogue scale (rated 0-10) in response to a finger prick pain induction. Parent-measured resting blood pressure was inversely associated with boys' pain ratings only. Cross-sectionally, lower pain ratings were related to higher SBP, univariately. Longitudinally, pain ratings predicted higher DBP, even after controlling for covariates. Determining when and how the relation between blood pressure and pain sensitivity emerges may elucidate the pathophysiology of hypertension. Copyright © 2013 Society for Psychophysiological Research.

  9. Allergic rhinitis and arterial blood pressure: a population-based study.

    Science.gov (United States)

    Sakallioglu, O; Polat, C; Akyigit, A; Cetiner, H; Duzer, S

    2018-05-01

    To investigate the likelihood of allergic rhinitis and potential co-morbidities, and to assess whether allergic rhinitis is associated with arterial blood pressure and hypertension. In this population-based study, 369 adults with allergic rhinitis and asthma were assessed via a questionnaire and immunoglobulin E levels. There were four groups: control (n = 90), allergic rhinitis (n = 99), asthma (n = 87) and hypertension (n = 93). Arterial blood pressure was measured in all groups. There were no significant differences in systolic or diastolic blood pressure between males and females in any group. Pairwise comparisons revealed no significant differences between: the control and allergic rhinitis groups, the control and asthma groups, or the allergic rhinitis and asthma groups. The systolic and diastolic blood pressure values of males and females were significantly higher in the hypertension group than the allergic rhinitis group. There were no significant differences in systolic blood pressure or diastolic blood pressure for seasonal and perennial allergic rhinitis patients. Rhinitis was not associated with increased blood pressure. Allergic rhinitis can coincide with asthma and hypertension. The findings do not support the need for blood pressure follow up in allergic rhinitis patients.

  10. Psoriasis and high blood pressure.

    Science.gov (United States)

    Salihbegovic, Eldina Malkic; Hadzigrahic, Nermina; Suljagic, Edin; Kurtalic, Nermina; Sadic, Sena; Zejcirovic, Alema; Mujacic, Almina

    2015-02-01

    Psoriasis is a chronic skin ailment which can be connected with an increased occurrence of other illnesses, including high blood pressure. A prospective study has been conducted which included 70 patients affected by psoriasis, both genders, older than 18 years. Average age being 47,14 (SD= ±15,41) years, from that there were 36 men or 51,43 and 34 women or 48,57%. Average duration of psoriasis was 15,52 (SD=±12,54) years. Frequency of high blood pressure in those affected by psoriasis was 54,28%. Average age of the patients with psoriasis and high blood pressure was 53,79 year (SD=±14,15) and average duration of psoriasis was 17,19 years (SD=±13,51). Average values of PASI score were 16,65. Increase in values of PASI score and high blood pressure were statistically highly related (r=0,36, p=0,0001). Psoriasis was related to high blood pressure and there was a correlation between the severity of psoriasis and high blood pressure.

  11. How Accurate Are Home Blood Pressure Devices in Use? A Cross-Sectional Study.

    Directory of Open Access Journals (Sweden)

    Marcel Ruzicka

    Full Text Available Out of office blood pressure measurements, using either home monitors or 24 hour ambulatory monitoring, is widely recommended for management of hypertension. Though validation protocols, meant to be used by manufacturers, exist for blood pressure monitors, there is scant data in the literature about the accuracy of home blood pressure monitors in actual clinical practice. We performed a chart review in the blood pressure assessment clinic at a tertiary care centre.We assessed the accuracy of home blood pressure monitors used by patients seen in the nephrology clinic in Ottawa between the years 2011 to 2014. We recorded patient demographics and clinical data, including the blood pressure measurements, arm circumference and the manufacturer of the home blood pressure monitor. The average of BP measurements performed with the home blood pressure monitor, were compared to those with the mercury sphygmomanometer. We defined accuracy based on a difference of 5 mm Hg in the blood pressure values between the home monitor and mercury sphygmomanometer readings. The two methods were compared using a Bland-Altman plot and a student's t-test.The study included 210 patients. The mean age of the study population was 67 years and 61% was men. The average mid-arm circumference was 32.2 cms. 30% and 32% of the home BP monitors reported a mean systolic and diastolic BP values, respectively, different from the mercury measurements by 5 mm Hg or more. There was no significant difference between the monitors that were accurate versus those that were not when grouped according to the patient characteristics, cuff size or the brand of the home monitor.An important proportion of home blood pressure monitors used by patients seen in our nephrology clinic were inaccurate. A re-validation of the accuracy and safety of the devices already in use is prudent before relying on these measurements for clinical decisions.

  12. High Blood Pressure in Adolescents of Curitiba: Prevalence and Associated Factors.

    Science.gov (United States)

    Bozza, Rodrigo; Campos, Wagner de; Barbosa Filho, Valter Cordeiro; Stabelini Neto, Antonio; Silva, Michael Pereira da; Maziero, Renato Silva Barbosa

    2016-05-01

    Arterial hypertension is a major public health problem and has increased considerably in young individuals in past years. Thus, identifying factors associated with this condition is important to guide intervention strategies in this population. To determine high blood pressure prevalence and its associated factors in adolescents. A random sample of 1,242 students enrolled in public schools of the city of Curitiba (PR) was selected. Self-administered questionnaires provided family history of hypertension, daily energy expenditure, smoking habit, daily fat intake, and socioeconomic status. Waist circumference was measured following standardized procedures, and blood pressure was measured with appropriate cuffs in 2 consecutive days to confirm high blood pressure. Relative frequency and confidence interval (95%CI) indicated high blood pressure prevalence. Bivariate and multivariate analyses assessed the association of risk factors with high blood pressure. The high blood pressure prevalence was 18.2% (95%CI 15.2-21.6). Individuals whose both parents had hypertension [odds ratio (OR), 2.22; 95%CI 1.28-3.85] and those with high waist circumference (OR, 2.1; 95%CI 1.34-3.28) had higher chances to develop high blood pressure. Positive family history of hypertension and high waist circumference were associated with high blood pressure in adolescents. These factors are important to guide future interventions in this population.

  13. High Blood Pressure in Adolescents of Curitiba: Prevalence and Associated Factors

    Directory of Open Access Journals (Sweden)

    Rodrigo Bozza

    2016-01-01

    Full Text Available Abstract Background: Arterial hypertension is a major public health problem and has increased considerably in young individuals in past years. Thus, identifying factors associated with this condition is important to guide intervention strategies in this population. Objective: To determine high blood pressure prevalence and its associated factors in adolescents. Methods: A random sample of 1,242 students enrolled in public schools of the city of Curitiba (PR was selected. Self-administered questionnaires provided family history of hypertension, daily energy expenditure, smoking habit, daily fat intake, and socioeconomic status. Waist circumference was measured following standardized procedures, and blood pressure was measured with appropriate cuffs in 2 consecutive days to confirm high blood pressure. Relative frequency and confidence interval (95%CI indicated high blood pressure prevalence. Bivariate and multivariate analyses assessed the association of risk factors with high blood pressure. Results: The high blood pressure prevalence was 18.2% (95%CI 15.2-21.6. Individuals whose both parents had hypertension [odds ratio (OR, 2.22; 95%CI 1.28-3.85] and those with high waist circumference (OR, 2.1; 95%CI 1.34-3.28 had higher chances to develop high blood pressure. Conclusion: Positive family history of hypertension and high waist circumference were associated with high blood pressure in adolescents. These factors are important to guide future interventions in this population.

  14. Preventing High Blood Pressure

    Science.gov (United States)

    ... Heart Disease Cholesterol Salt Million Hearts® WISEWOMAN Preventing High Blood Pressure: Healthy Living Habits Recommend on Facebook Tweet Share ... meal and snack options can help you avoid high blood pressure and its complications. Be sure to eat plenty ...

  15. The Role of Central Blood Pressure Monitoring in the Management of Hypertension.

    Science.gov (United States)

    Ochoa, Adrian; Patarroyo-Aponte, Gabriel; Rahman, Mahboob

    2018-04-19

    Central blood pressure is a novel predictor of cardiovascular risk that can be measured in the clinical setting using currently available technology. This paper will review current available methods of central blood pressure monitoring as well as its impact in cardiac and renal disease. Both aortic and carotid systolic blood pressure are independently associated with cardiovascular mortality and serious cardiac events. Furthermore, studies show that systolic aortic blood pressure has been shown to be superior predictor of cardiovascular as compared to brachial blood pressure. Inhibitors of the renin angiotensin axis may have a beneficial effect on central blood pressure; however, long term studies evaluating the impact of lowering central blood pressure on clinical outcomes are lacking. Central blood pressure is a good predictor of cardiovascular risk. As more studies emerge demonstrating the value of central blood pressure as a therapeutic target, it is possible that targeting central blood pressure may become an important part of the armamentarium to lower cardiovascular risk.

  16. 21 CFR 868.1200 - Indwelling blood oxygen partial pressure (PO2) analyzer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Indwelling blood oxygen partial pressure (PO2... Indwelling blood oxygen partial pressure (PO2) analyzer. (a) Identification. An indwelling blood oxygen... electrode) and that is used to measure, in vivo, the partial pressure of oxygen in blood to aid in...

  17. Blood Pressure Out of the Office: Its Time Has Finally Come.

    Science.gov (United States)

    Krakoff, Lawrence R

    2016-03-01

    The diagnosis of hypertension includes measurement of blood pressure out of the office by either 24-hour ambulatory monitoring or home blood pressure monitoring. These methods have led to recognition of "white coat hypertension" (WCH) and "masked hypertension" (MH). Research in the 1930s first demonstrated that blood pressures in the office were often far different from those out of the office, at a time when there was no effective treatment. International attention was focused on another imminent world war and a highly controversial election in the United States. Hypertension was not a priority for concern. From the 1950s onward: (i) epidemiology linked hypertension to risk of cardiovascular disease, (ii) effective and safe drugs for treatment of hypertension appeared, (iii) randomized clinical trials demonstrated that drug treatment of hypertension is highly effective for prevention of cardiovascular disease, and (iv) advances in technology led to development of small, portable devices for recording blood pressure noninvasively at home or during usual activities. Accurate measurement of blood pressure in "real life" is now necessary and feasible for appropriate diagnosis and assessment of treatment. Out-of-office blood pressure measurement is emerging as the standard of care for hypertension. © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Sphygmomanometric and ambulatory blood pressures as forerunners of carotid and femoral intima-media thickness.

    NARCIS (Netherlands)

    Dechering, D.G.; Wizner, B.; Adiyaman, A.; Nawrot, T.; Jin, Y.; Richart, T.; Kuznetsova, T.; Struijker-Boudier, H.A.; Thien, Th.; Staessen, J.A.

    2009-01-01

    OBJECTIVE: Studies directly comparing the associations of intima-media thickness with blood pressure (BP) on manual sphygmomanometric blood pressure measurement (SBPM) and 24-h ambulatory blood pressure measurement (ABPM) are scarce and have a cross-sectional design. METHODS: At baseline, we

  19. Lack of association between systolic blood pressure and blood viscosity in normotensive healthy subjects.

    Science.gov (United States)

    Irace, Concetta; Carallo, Claudio; Scavelli, Faustina; Loprete, Antonio; Merante, Valentina; Gnasso, Agostino

    2012-01-01

    A direct relationship between blood pressure and viscosity has frequently been reported, although clear data are not available. To better understand the relationship between these two variables, we evaluated blood viscosity and blood pressure in a group of healthy subjects without cardiovascular risk factors. Healthy subjects were selected from participants in a campaign of prevention of cardiovascular disease (n = 103). They underwent blood sampling for measurement of plasma and blood viscosity, haematocrit, blood lipids and glucose. The quantity and distribution of body fat was assessed by body mass index and waist/hip ratio, respectively. Systolic blood pressure (SBP) correlated significantly with age (r = 0.222) and waist/hip ratio (r = 0.374). Diastolic blood pressure (DBP) correlated significantly with waist/hip ratio (r = 0.216), haematocrit (r = 0.333) and blood viscosity (r = 0.258). Multiple linear regression analyses demonstrated that the only variable significantly associated with SBP was age, while haematocrit was the only variable significantly associated with DBP. Blood viscosity was closely related to waist/hip ratio. These findings show that SBP, in healthy subjects, is not influenced by haematocrit and blood viscosity. In contrast, DBP is related to the values of haematocrit. Among classical cardiovascular risk factors, waist/hip ratio is closely related to blood viscosity.

  20. Associations between bacterial infections and blood pressure in pregnancy.

    Science.gov (United States)

    Petry, Clive J; Ong, Ken K; Hughes, Ieuan A; Acerini, Carlo L; Dunger, David B

    2017-10-01

    To test the hypothesis that bacterial infections in pregnancy are related to maternal blood pressure. Bacterial infection was assessed using antibiotic usage as a surrogate and its association with blood pressure in pregnancy tested in the Cambridge Baby Growth Study. Antibiotic usage in pregnancy was self-reported in questionnaires. Blood pressure measurements at four time points in pregnancy were collected from the hospital notes of 622 women. Using all the available blood pressure readings (adjusted for weeks gestation) antibiotic usage was associated with a higher mean arterial blood pressure across pregnancy: antibiotics used 85(84, 87)mmHg vs. no antibiotics used 83 (83, 84) mmHg (β=2.3 (0.6, 4.0) mmHg, p=9.6×10 -3 , from 621 individuals). Further analysis revealed that antibiotic usage was associated with diastolic (β=2.3 (0.6, 4.0) mmHg; p=7.0×10 -3 ) more than systolic blood pressure (β=1.4(-0.9, 3.7)mmHg; p=0.2). The effect size associated with antibiotic usage appeared to rise slightly after the first trimester. Bacterial infection in pregnancy, as assessed by self-reported antibiotic usage, is associated with small rises in blood pressure. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  1. Dorsalis pedis arterial pressure is lower than noninvasive arm blood pressure in normotensive patients under sevoflurane anesthesia.

    Science.gov (United States)

    Chen, Yan; Wang, Enqin; Zhu, Yuan; Li, Yongshuai; Lu, Kaizhi

    2016-02-01

    It is widely known that blood pressure (BP) in the lower extremity is higher than in the upper extremity. However, whether this phenomenon remains the same during general anesthesia is still unclear. This study aims to investigate the difference between invasive dorsalis pedis artery (DPA) pressure and the most commonly used noninvasive arm pressure during sevoflurane anesthesia. A total of 50 normotensive Chinese patients were enrolled in this observational study. Invasive DPA pressure, noninvasive arm pressure, and systemic vascular resistance index were assessed simultaneously. BP data during the entire surgery were analyzed through a Bland-Altman plot for repeated measures. The concordance of BP variation in the DPA and the arm was analyzed using four-quadrant plots and linear regression. The time-dependent changes in BP and the systemic vascular resistance index were also evaluated. Data from 46 effective cases were analyzed. Bias (95% limits of agreement) was -7.40 mmHg (-20.36 to +5.57 mmHg) for mean blood pressure, +3.54 mmHg (-20.32 to +27.41 mmHg) for systolic blood pressure, and -10.20 mmHg (-23.66 to +3.26 mmHg) for diastolic blood pressure, respectively. The concordance of BP variation at the two measurement sites was clinically acceptable. DPA pressure and vascular resistance in the lower limb decreased gradually during surgery. DPA pressure tends to be lower than arm pressure under sevoflurane anesthesia, especially the mean blood pressure and the diastolic blood pressure. Hence, noninvasive arm BP monitoring is recommend to be retained when invasive BP is measured at the DPA, so as to allow clinicians to comprehensively evaluate the BP condition of the patients and make appropriate therapeutic decisions.

  2. Associations between cadmium levels in blood and urine, blood pressure and hypertension among Canadian adults

    Energy Technology Data Exchange (ETDEWEB)

    Garner, Rochelle E., E-mail: rochelle.garner@canada.ca [Health Analysis Division, Statistics Canada, Ottawa, Ontario (Canada); Levallois, Patrick [Direction de la santé environnementale et de la toxicologie, Institut National de Santé Publique du Québec, Québec City, Québec (Canada); Axe santé des populations et pratiques optimales en santé, Centre de Recherche du CHU de Québec-Université Laval, Québec City, Québec (Canada)

    2017-05-15

    Background: Cadmium has been inconsistently related to blood pressure and hypertension. The present study seeks to clarify the relationship between cadmium levels found in blood and urine, blood pressure and hypertension in a large sample of adults. Methods: The study sample included participants ages 20 through 79 from multiple cycles of the Canadian Health Measures Survey (2007 through 2013) with measured blood cadmium (n=10,099) and urinary cadmium (n=6988). Linear regression models examined the association between natural logarithm transformed cadmium levels and blood pressure (separate models for systolic and diastolic blood pressure) after controlling for known covariates. Logistic regression models were used to examine the association between cadmium and hypertension. Models were run separately by sex, smoking status, and body mass index category. Results: Men had higher mean systolic (114.8 vs. 110.8 mmHg, p<0.01) and diastolic (74.0 vs. 69.6 mmHg, p<0.01) blood pressure compared to women. Although, geometric mean blood (0.46 vs. 0.38 µg/L, p<0.01) and creatinine-adjusted standardized urinary cadmium levels (0.48 vs. 0.38 µg/L, p<0.01) were higher among those with hypertension, these differences were no longer significant after adjustment for age, sex and smoking status. In overall regression models, increases in blood cadmium were associated with increased systolic (0.70 mmHg, 95% confidence interval [CI]=0.25–1.16, p<0.01) and diastolic blood pressure (0.74 mmHg, 95% CI=0.30–1.19, p<0.01). The associations between urinary cadmium, blood pressure and hypertension were not significant in overall models. Model stratification revealed significant and negative associations between urinary cadmium and hypertension among current smokers (OR=0.61, 95% CI=0.44–0.85, p<0.01), particularly female current smokers (OR=0.52, 95% CI=0.32–0.85, p=0.01). Conclusion: This study provides evidence of a significant association between cadmium levels, blood pressure

  3. Associations between cadmium levels in blood and urine, blood pressure and hypertension among Canadian adults

    International Nuclear Information System (INIS)

    Garner, Rochelle E.; Levallois, Patrick

    2017-01-01

    Background: Cadmium has been inconsistently related to blood pressure and hypertension. The present study seeks to clarify the relationship between cadmium levels found in blood and urine, blood pressure and hypertension in a large sample of adults. Methods: The study sample included participants ages 20 through 79 from multiple cycles of the Canadian Health Measures Survey (2007 through 2013) with measured blood cadmium (n=10,099) and urinary cadmium (n=6988). Linear regression models examined the association between natural logarithm transformed cadmium levels and blood pressure (separate models for systolic and diastolic blood pressure) after controlling for known covariates. Logistic regression models were used to examine the association between cadmium and hypertension. Models were run separately by sex, smoking status, and body mass index category. Results: Men had higher mean systolic (114.8 vs. 110.8 mmHg, p<0.01) and diastolic (74.0 vs. 69.6 mmHg, p<0.01) blood pressure compared to women. Although, geometric mean blood (0.46 vs. 0.38 µg/L, p<0.01) and creatinine-adjusted standardized urinary cadmium levels (0.48 vs. 0.38 µg/L, p<0.01) were higher among those with hypertension, these differences were no longer significant after adjustment for age, sex and smoking status. In overall regression models, increases in blood cadmium were associated with increased systolic (0.70 mmHg, 95% confidence interval [CI]=0.25–1.16, p<0.01) and diastolic blood pressure (0.74 mmHg, 95% CI=0.30–1.19, p<0.01). The associations between urinary cadmium, blood pressure and hypertension were not significant in overall models. Model stratification revealed significant and negative associations between urinary cadmium and hypertension among current smokers (OR=0.61, 95% CI=0.44–0.85, p<0.01), particularly female current smokers (OR=0.52, 95% CI=0.32–0.85, p=0.01). Conclusion: This study provides evidence of a significant association between cadmium levels, blood pressure

  4. Diet, blood pressure, and multicollinearity.

    Science.gov (United States)

    Reed, D; McGee, D; Yano, K; Hankin, J

    1985-01-01

    Recent reports of an inverse association between dietary calcium intake and hypertension stimulated this analysis of the relationship of blood pressure to more than 20 dietary factors among a group of 8000 Japanese men in Hawaii. Reported intakes of potassium, calcium, protein, and milk were all inversely associated with blood pressure levels when examined one at a time while controlling for other risk factors. Alcohol intake was directly associated with blood pressure, and was treated as a confounding variable in the analysis. The association of potassium intake with blood pressure was relatively stronger than the associations for other nutrients, but the intake of potassium was so highly correlated with intakes of calcium, milk, and protein that it was not statistically possible to identify the independent association of potassium and blood pressure. Calcium intake was strongly correlated with milk and potassium intakes, and only calcium from dairy sources was associated with blood pressure. These data thus indicate that several dietary factors are inversely related to blood pressure levels independently of other risk factors such as age, body mass, and alcohol intake. The high degree of intercorrelation (multicollinearity) among these dietary factors, however, indicates that the independent role of any specific nutrient cannot be conclusively separated from the possible effects of other nutrients in this type of study.

  5. Intensive versus conventional blood pressure monitoring in a general practice population. The Blood Pressure Reduction in Danish General Practice trial: a randomized controlled parallel group trial.

    Science.gov (United States)

    Klarskov, Pia; Bang, Lia E; Schultz-Larsen, Peter; Gregers Petersen, Hans; Benee Olsen, David; Berg, Ronan M G; Abrahamsen, Henrik; Wiinberg, Niels

    2018-01-17

    To compare the effect of a conventional to an intensive blood pressure monitoring regimen on blood pressure in hypertensive patients in the general practice setting. Randomized controlled parallel group trial with 12-month follow-up. One hundred and ten general practices in all regions of Denmark. One thousand forty-eight patients with essential hypertension. Conventional blood pressure monitoring ('usual group') continued usual ad hoc blood pressure monitoring by office blood pressure measurements, while intensive blood pressure monitoring ('intensive group') supplemented this with frequent home blood pressure monitoring and 24-hour ambulatory blood pressure monitoring. Mean day- and night-time systolic and diastolic 24-hour ambulatory blood pressure. Change in systolic and diastolic office blood pressure and change in cardiovascular risk profile. Of the patients, 515 (49%) were allocated to the usual group, and 533 (51%) to the intensive group. The reductions in day- and night-time 24-hour ambulatory blood pressure were similar (usual group: 4.6 ± 13.5/2.8 ± 82 mmHg; intensive group: 5.6 ± 13.0/3.5 ± 8.2 mmHg; P = 0.27/P = 0.20). Cardiovascular risk scores were reduced in both groups at follow-up, but more so in the intensive than in the usual group (P = 0.02). An intensive blood pressure monitoring strategy led to a similar blood pressure reduction to conventional monitoring. However, the intensive strategy appeared to improve patients' cardiovascular risk profile through other effects than a reduction of blood pressure. Clinical Trials NCT00244660. © The Author 2018. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Influence of Individual Differences on the Calculation Method for FBG-Type Blood Pressure Sensors.

    Science.gov (United States)

    Koyama, Shouhei; Ishizawa, Hiroaki; Fujimoto, Keisaku; Chino, Shun; Kobayashi, Yuka

    2016-12-28

    In this paper, we propose a blood pressure calculation and associated measurement method that by using a fiber Bragg grating (FBG) sensor. There are several points at which the pulse can be measured on the surface of the human body, and when a FBG sensor located at any of these points, the pulse wave signal can be measured. The measured waveform is similar to the acceleration pulse wave. The pulse wave signal changes depending on several factors, including whether or not the individual is healthy and/or elderly. The measured pulse wave signal can be used to calculate the blood pressure using a calibration curve, which is constructed by a partial least squares (PLS) regression analysis using a reference blood pressure and the pulse wave signal. In this paper, we focus on the influence of individual differences from calculated blood pressure based on each calibration curve. In our study, the calculated blood pressure from both the individual and overall calibration curves were compared, and our results show that the calculated blood pressure based on the overall calibration curve had a lower measurement accuracy than that based on an individual calibration curve. We also found that the influence of the individual differences on the calculated blood pressure when using the FBG sensor method were very low. Therefore, the FBG sensor method that we developed for measuring the blood pressure was found to be suitable for use by many people.

  7. Alcohol: Does It Affect Blood Pressure?

    Science.gov (United States)

    Alcohol: Does it affect blood pressure? Does drinking alcohol affect your blood pressure? Answers from Sheldon G. Sheps, M.D. Drinking too much alcohol can raise blood pressure to unhealthy levels. Having ...

  8. Comparison of an implantable telemetry device and an oscillometric monitor for measurement of blood pressure in anaesthetized and unrestrained green iguanas (Iguana iguana).

    Science.gov (United States)

    Chinnadurai, Sathya K; DeVoe, Ryan; Koenig, Amie; Gadsen, Nadia; Ardente, Amanda; Divers, Stephen J

    2010-09-01

    The objective of this study was to compare an implanted direct blood pressure monitor and a non-invasive oscillometric unit for use in anesthetized and awake green iguanas. Prospective experimental trial. Four male and four female adult green iguanas (Iguana iguana) weighing 1833 +/- 534 g. For each animal, the carotid artery was surgically exposed and the catheter tip of the pressure transducer was placed in the aortic arch. Non-invasive blood pressure was measured using a cuff over the left femoral region. Pulse rate, respiratory rate and arterial blood pressure (ABP) measurements were taken every 5 minutes. Direct ABP measurements consisted of recording numerical values and graphic output. Simultaneous direct and indirect measurements were repeated in awake animals. The oscillometric device failed to provide a reading in over 80% of attempts, and failed to provide readings that correlated with direct measurements. The implanted direct transducer was capable of detecting blood pressures throughout all ABP ranges examined. The implantable transducer was a reliable means of determining blood pressure in this study, while the oscillometric device was unreliable and often failed to provide any reading. We do not recommend using the oscillometric device as described in a research or clinical setting for green iguanas. The advantages of an implantable device include the ability to monitor awake and anesthetized subjects remotely and continuously. These monitors are small, biocompatible and function across a wide range of ABP.

  9. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...... device for monitoring blood pressure in 35 patients with cirrhosis and 35 healthy matched controls. During the daytime, SBP, DBP, and MAP were significantly lower in the patients than in the controls (median 118 vs. 127; 70 vs. 78; 86 vs. 94 mm Hg, P blood pressures...... were almost similar in the two groups (108 vs. 110; 65 vs. 67; 78 vs. 82 mm Hg, NS). Conversely, HR was significantly higher in the patients both in the daytime (86 vs. 72/min, P blood pressure and HR from daytime...

  10. High Blood Pressure (Hypertension)

    Science.gov (United States)

    ... other risk factors, like diabetes, you may need treatment. How does high blood pressure affect pregnant women? A few women will get ... HIV, Birth Control Heart Health for Women Pregnancy Menopause More Women's Health ... High Blood Pressure--Medicines to Help You Women and Diabetes Heart ...

  11. Validation of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Liu, Ming; Li, Yan; Wang, Ji-Guang

    2014-02-01

    The present study aimed to evaluate the accuracy of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (14 women, mean age of 47 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM63S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The AVITA BPM63S device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 68/99, 89/99, and 96/99, respectively, for systolic blood pressure, and 75/99, 95/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-four and 25 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required ≥24). One and two participants for systolic and diastolic blood pressure, respectively, had all three device-observers differences greater than 5 mmHg. The AVITA BPM63S automated oscillometric upper arm blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement at home in adults.

  12. African Americans and High Blood Pressure

    Science.gov (United States)

    ANSWERS by heart Lifestyle + Risk Reduction High Blood Pressure What About African Americans and High Blood Pressure? African Americans in the U.S. have a higher prevalence of high blood pressure (HBP) than ...

  13. Blood pressure as a therapeutic target in stroke.

    Science.gov (United States)

    Armario, Pedro; de la Sierra, Alejandro

    2009-01-01

    Stroke, as a clinical manifestation of the cardiovascular diseases, is one of the leading causes of death and disability in both developed and developing countries. Hypertension is by far, the most important risk factor for stroke. Epidemiological data indicate that the risk of stroke increases with both systolic and diastolic blood pressure elevation, from levels of 115/75 mmHg. It is also evident that most adults worldwide have values above these limits, thus emphasizing the importance of blood pressure as a risk factor for stroke. Clinical trials of antihypertensive treatment, both in studies that have compared active drugs against placebo or in those comparing different types of drugs have clearly demonstrated a protective effect of blood pressure reduction in the prevention of stroke. The degree of protection is directly related to blood pressure reduction and, the lower the level, the better the prognosis. Although data on secondary stroke prevention are scarcer, studies also seem to indicate that lowering blood pressure with antihypertensive treatment protects against stroke recurrence. At the present moment there is still uncertainty on 2 different aspects regarding the relationship between antihypertensive treatment and stroke. First, the blood pressure management during acute stroke has not adequately investigated in clinical trials. Second, the possibility of a protective role of specific types of antihypertensive drugs beyond blood pressure reduction is a matter of debate. Independently of these unresolved issues, prevention of hypertension development by lifestyle changes and adequate treatment and control to the hypertensive population will be a very effective measure in reducing stroke incidence, stroke recurrence, and stroke mortality.

  14. The Relationship Between Preoperative and Primary Care Blood Pressure Among Veterans Presenting from Home for Surgery. Is There Evidence for Anesthesiologist-Initiated Blood Pressure Referral?

    Science.gov (United States)

    Schonberger, Robert B.; Burg, Matthew M.; Holt, Natalie; Lukens, Carrie L.; Dai, Feng; Brandt, Cynthia

    2011-01-01

    Background American College of Cardiology/American Heart Association guidelines describe the perioperative evaluation as “a unique opportunity to identify patients with hypertension,” however factors such as anticipatory stress or medication noncompliance may induce a bias toward higher blood pressure, leaving clinicians unsure about how to interpret preoperative hypertension. Information describing the relationship between preoperative intake blood pressure and primary care measurements could help anesthesiologists make primary care referrals for improved blood pressure control in an evidence-based fashion. We hypothesized that the preoperative examination provides a useful basis for initiating primary care blood pressure referral. Methods We analyzed retrospective data on 2807 patients who arrived from home for surgery and who were subsequently evaluated within 6 months after surgery in the primary care center of the same institution. After descriptive analysis, we conducted multiple linear regression analysis to identify day-of-surgery (DOS) factors associated with subsequent primary care blood pressure. We calculated the sensitivity, specificity, and positive and negative predictive value of different blood pressure referral thresholds using both a single-measurement and a two-stage screen incorporating recent preoperative and DOS measurements for identifying patients with subsequently elevated primary care blood pressure. Results DOS systolic blood pressure (SBP) was higher than subsequent primary care SBP by a mean bias of 5.5mmHg (95% limits of agreement +43.8 to −32.8). DOS diastolic blood pressure (DBP) was higher than subsequent primary care DBP by a mean bias of 1.5mmHg (95% limits of agreement +13.0 to −10.0). Linear regression of DOS factors explained 19% of the variability in primary care SBP and 29% of the variability in DBP. Accounting for the observed bias, a two-stage SBP referral screen requiring preoperative clinic SBP≥140mmHg and DOS

  15. Relationship between systemic hemodynamics and ambulatory blood pressure level are sex dependent.

    Science.gov (United States)

    Alfie, J; Waisman, G D; Galarza, C R; Magi, M I; Vasvari, F; Mayorga, L M; Cámera, M I

    1995-12-01

    Sex-related differences in systemic hemodynamics were analyzed by means of cardiac index and systemic vascular resistance according to the level of daytime ambulatory blood pressure. In addition, we assessed the relations between ambulatory blood pressure measurements and systemic hemodynamics in male and female patients. We prospectively included 52 women and 53 men referred to our unit for evaluation of arterial hypertension. Women and men were grouped according to the level of daytime mean arterial pressure: or = 110 mm Hg. Patients underwent noninvasive evaluation of resting hemodynamics (impedance cardiography) and 24-hour ambulatory blood pressure monitoring. Compared with women men with lower daytime blood pressure had a 12% higher systemic vascular resistance index (P = NS) and a 14% lower cardiac index (P < .02), whereas men with higher daytime blood pressure had a 25% higher vascular resistance (P < .003) and a 21% lower cardiac index (P < .0004). Furthermore, in men systemic vascular resistance correlated positively with both daytime and nighttime systolic and diastolic blood pressures, whereas cardiac index correlated negatively only with daytime diastolic blood pressure. In contrast, women did not exhibit any significant correlation between hemodynamic parameters and ambulatory blood pressure measurements. In conclusion, sex-related differences in systemic hemodynamics were more pronounced in the group with higher daytime hypertension. The relations between systemic hemodynamics and ambulatory blood pressure level depended on the sex of the patient. In men a progressive circulatory impairment underlies the increasing level of ambulatory blood pressure, but this was not observed in women.

  16. Blood Pressure Variability and Cognitive Function Among Older African Americans: Introducing a New Blood Pressure Variability Measure.

    Science.gov (United States)

    Tsang, Siny; Sperling, Scott A; Park, Moon Ho; Helenius, Ira M; Williams, Ishan C; Manning, Carol

    2017-09-01

    Although blood pressure (BP) variability has been reported to be associated with cognitive impairment, whether this relationship affects African Americans has been unclear. We sought correlations between systolic and diastolic BP variability and cognitive function in community-dwelling older African Americans, and introduced a new BP variability measure that can be applied to BP data collected in clinical practice. We assessed cognitive function in 94 cognitively normal older African Americans using the Mini-Mental State Examination (MMSE) and the Computer Assessment of Mild Cognitive Impairment (CAMCI). We used BP measurements taken at the patients' three most recent primary care clinic visits to generate three traditional BP variability indices, range, standard deviation, and coefficient of variation, plus a new index, random slope, which accounts for unequal BP measurement intervals within and across patients. MMSE scores did not correlate with any of the BP variability indices. Patients with greater diastolic BP variability were less accurate on the CAMCI verbal memory and incidental memory tasks. Results were similar across the four BP variability indices. In a sample of cognitively intact older African American adults, BP variability did not correlate with global cognitive function, as measured by the MMSE. However, higher diastolic BP variability correlated with poorer verbal and incidental memory. By accounting for differences in BP measurement intervals, our new BP variability index may help alert primary care physicians to patients at particular risk for cognitive decline.

  17. Validation of the iHealth BP7 wrist blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Wang, Qing; Zhao, Huadong; Chen, Wan; Li, Ni; Wan, Yi

    2014-02-01

    The aim of this study was to validate the iHealth BP7 wireless wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. A total of 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained for validation. The ESH-IP revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. The device produced 66, 87, and 97 measurements within 5, 10, and 15 mmHg for systolic blood pressure (SBP) and 72, 93, and 99 mmHg for diastolic blood pressure (DBP), respectively. The mean±SD device-observer difference was -0.7±6.9 mmHg for SBP and -1.0±5.1 mmHg for DBP. The number of participants with two or three device-observer differences within 5 mmHg was 25 for SBP and 26 for DBP; furthermore, there were three participants for SBP and one participant for DBP, with none of the device-observer differences within 5 mmHg. On the basis of the validation results, the iHealth BP7 wireless wrist blood pressure monitor can be recommended for self-measurement in an adult population.

  18. Blood pressure in childhood : epidemiological probes into the aetiology of high blood pressure

    NARCIS (Netherlands)

    A. Hofman (Albert)

    1983-01-01

    textabstractHigh arterial blood pressure takes a heavy toll in western populations (1 ). Its causes are still largely unknown, but its sequelae, a variety of cardiovascular and renal diseases, have been referred to as "a modern scourge" (2). High blood pressure of unknown cause, or

  19. Validation of the Andon KD-5851 upper arm blood pressure monitor, for self-measurement according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Wu, Lili; Jiao, Yinghui; Wang, Chengdong; Chen, Lei; Di, Dalin; Zhang, Haiyan

    2015-08-01

    This study aimed to validate the Andon KD-5851 upper arm blood pressure (BP) monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. A total of 33 eligible participants were included in the study. Sequential measurements of BPs were performed using a mercury sphygmomanometer and the device, and the data analysis was carried out following precisely the ESH-IP revision 2010. The device had 82, 98, and 99 measurements within 5, 10, and 15 mmHg for systolic blood pressure and 85, 95, and 99 measurements for diastolic blood pressure, respectively. The average device-observer difference was -0.53±4.00 mmHg for systolic blood pressure and -1.15±4.06 mmHg for diastolic blood pressure. The device passed all the criteria according to the ESH-IP revision 2010. According to the validation results on the basis of the ESH-IP revision 2010, the Andon KD-5851 upper arm BP monitor can be recommended for self/home measurement in adults. Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved.

  20. Cell Phone Information Seeking Explains Blood Pressure in African American Women.

    Science.gov (United States)

    Jones, Lenette M; Veinot, Tiffany C; Pressler, Susan J

    2018-05-01

    Although cell phone use and Internet access via cell phone is not marked by racial disparities, little is known about how cell phone use relates to blood pressure and health information seeking behaviors. The purposes of this study were to (a) describe Internet activities, cell phone use, and information seeking; (b) determine differences in blood pressure and information seeking between cell phone information seekers and nonseekers; and (c) examine cell phone information seeking as a predictor of blood pressure in African American women. Participants ( N = 147) completed a survey and had their blood pressure measured. Independent-sample t tests showed a significant difference in systolic blood pressure in cell phone information seekers and nonseekers. Linear regression revealed cell phone information seeking as an independent predictor of systolic blood pressure, despite confounders. It is possible that cell phone information seekers were using health information to make decisions about self-management of blood pressure.

  1. Reference data for distal blood pressure in healthy elderly and middle-aged individuals measured with the strain gauge technique. Part I: Resting distal blood pressure

    DEFF Research Database (Denmark)

    Arveschoug, Anne Kirstine; Vammen, Birthe; Yoshinaka, Emmy

    2008-01-01

    pressure and DBPtoe - DBPankle) were found in the new reference data compared to the old. No significant difference between the mean values of the gradient (DBPankle - systolic arm blood pressure) was found between the old and new reference data, although the variation was significantly wider in the new......Objective. Most patients referred to our department for distal blood pressure (DBP) determination on suspicion of arterial peripheral vascular disease (apvd) are more than 60 years of age, whereas the only available reference data for resting pressure are based on data from healthy individuals aged....... Material and methods. Group I comprised 31 healthy persons aged between 61 and 87 years and group II 14 healthy middle-aged hospital staff members aged between 45 and 58 years. Strict rules of inclusion were followed. Results. For group I, significantly greater gradients (DBPtoe - systolic arm blood...

  2. Effect of hematocrit and systolic blood pressure on cerebral blood flow in newborn infants

    International Nuclear Information System (INIS)

    Younkin, D.P.; Reivich, M.; Jaggi, J.L.; Obrist, W.D.; Delivoria-Papadopoulos, M.

    1987-01-01

    The effects of hematocrit and systolic blood pressure on cerebral blood flow were measured in 15 stable, low birth weight babies. CBF was measured with a modification of the xenon-133 ( 133 Xe) clearance technique, which uses an intravenous bolus of 133 Xe, an external chest detector to estimate arterial 133 Xe concentration, eight external cranial detectors to measure cephalic 133 Xe clearance curves, and a two-compartmental analysis of the cephalic 133 Xe clearance curves to estimate CBF. There was a significant inverse correlation between hematocrit and CBF, presumably due to alterations in arterial oxygen content and blood viscosity. Newborn CBF varied independently of systolic blood pressure between 60 and 84 mm Hg, suggesting an intact cerebrovascular autoregulatory mechanism. These results indicate that at least two of the factors that affect newborn animal CBF are operational in human newborns and may have important clinical implications

  3. Comparing Measures of General and Abdominal Adiposity as Predictors of Blood Pressure in College Students

    Science.gov (United States)

    Abshire, Demetrius A.; Mudd-Martin, Gia; Moser, Debra K.; Lennie, Terry A.

    2018-01-01

    Objective: To compare anthropometric measures of body mass index (BMI), waist circumference (WC), waist-to-height ratio (WHtR), and sagittal abdominal diameter (SAD) as predictors of blood pressure in college students. Participants: Students (N = 116) were recruited from November 2012 to May 2014 at an urban university and rural community…

  4. Validation of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure measuring devices in adults according to the International Protocol.

    Science.gov (United States)

    Altunkan, Sekip; Ilman, Nevzat; Altunkan, Erkan

    2007-04-01

    A variety of automatic blood measurement devices with diverse features have been introduced to the medical markets recently. Among these devices, models that measure at the wrist have become increasingly popular in self measurements. The objective of this study was to evaluate the accuracy of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure devices against the mercury sphygmomanometer in adults according to the International Protocol criteria. Fifty-four patients over 30 years of age were studied and classified based on the International Protocol range. Blood pressure measurements at the wrist with the Samsung SBM-100A and Microlife BP 3BU1-5 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential blood pressure measurements were taken. A total of 33 participants with randomly distributed arm circumferences were selected for both of the validation studies. During each validation study, 99 measurements were obtained for comparison from 33 participants. The first phase was performed on 15 participants and if the device passed this phase, 18 more participants were selected. Mean discrepancies and standard deviations of the device-sphygmomanometer were 0.9+/-9.2 and -2.7+/-9.3 mmHg for systolic blood pressure and -1.4+/-8.0 mmHg and 1.4+/-5.7 for diastolic blood pressure in the Samsung and Microlife study groups, respectively. The Samsung SBM-100A passed Phase 1 in 15 participants. Despite the fact that Microlife BP 3BU1-5 passed Phase 1 for diastolic pressure, it failed according to the systolic pressure criteria. Eighteen patients were added and Phase 2 was continued, in which Samsung SBM-100A failed to meet the criteria of Phases 2.1 and 2.2 for adults in systolic and diastolic blood pressure. It was found that the Microlife BP 3BU1-5 does not meet the criteria of either of Phases 2.1 and 2.2 for systolic blood pressure and Phase 2.2 for diastolic blood pressure. In this study, Samsung SBM

  5. Effects of aerobic exercise and drug therapy on blood pressure and ...

    African Journals Online (AJOL)

    EB

    Key words: Aerobic exercise, drug therapy, blood pressure, randomised controlled trial. African Health Sciences 2013; (1): .... body fat and displayed it on the screen of the meter. ... inelastible tape measure (Butterfly, China). Blood pressure ...

  6. Casual and ambulatory blood pressure monitoring in children with renal scarring

    Directory of Open Access Journals (Sweden)

    Miloševski Gordana

    2005-01-01

    Full Text Available INTRODUCTION Renal scarring is the most common cause of arterial hypertension in children. High blood pressure (BP and microalbuminuria contribute to the progression of chronic renal disease. OBJECTIVE The aims of the study were: to assess BP in children with renal scarring by continuous ambulatory blood pressure measurement (ABPM in comparison to the casual method (CBP, and to determine the correlation between ambulatory blood pressure (ABP and/or casual blood pressure (CBP values and proteinuria in children with renal scarring. METHOD This forward-looking study comprised thirty-five children (26 girls and 9 boys, aged between 3-13 years, 10.4±3.9, X+SD. Blood pressure was measured using the casual method (CBP with a mercury manometer; BP was measured three times and the average was taken as a referent value. ABPM was performed using the oscillometric method with the Space Labs device, model 90207. RESULTS 45.71% of patients were classified as hypertensive by ABPM, while only 22.6% of CBP measurements were above the 95th percentile (p<0.01. "White coat hypertension" was present in 40% of the patients. Non-dipping BP alteration was detected in 37.14% of the patients. CONCLUSION Nocturnal systolic hypertension (systolic non-dipping alteration is very frequent in children with renal scarring. Nocturnal diastolic blood pressure, detectable only via ABPM, is positively correlated with proteinuria and may be an initial sign of the progression of renal scarring. ABPM is more sensitive than CBP in the evaluation of BP in children with renal scarring.

  7. Insight of Human Stroke from blood flow and blood pressure

    Science.gov (United States)

    Chen, Zhi; Ivanov, Plamen Ch.; Hu, Kun; Stanley, H. Eugene

    2003-03-01

    Stroke is is one of the leading cause of death and disability in the world. It is well believed that stroke is caused by the disturbance of cerebrovascular autoregulation. We investigate the blood flow on the left and right middle cerebral artery and beat-to-beat blood pressure simultaneously measured from the finger, for both subjects with stroke and healthy subjects. Synchronization technique is used to distinguish the difference between these two groups.

  8. Home readings of blood pressure in assessment of hypertensive subjects

    DEFF Research Database (Denmark)

    Nielsen, P.E.; Myschetzky, P; Andersen, A R

    1986-01-01

    Out-patient clinic blood pressure (OPC-BP) was compared to home blood pressure (Home-BP) measured three times daily during a two week period in 122 consecutively referred hypertensive subjects. A semi-automatic device (TM-101) including a microphone for detection of Korotkoff-sounds, self......-deflation of cuff pressure and digital display of blood pressure was used. Mean difference between OPC-BP and Home-BP was systolic +13 mm Hg (range -21 - +100 mg Hg) and diastolic +5 mm Hg (range -27 - +36 mm Hg). Although a significant correlation could be demonstrated between Home-BP and OPC-BP, the inter...

  9. Blood pressure changes during barium enema

    International Nuclear Information System (INIS)

    Roach, S.C.; Martin, O.J.D.; Owen, A.; Martin, D.F.

    2001-01-01

    AIMS: To document blood pressure changes during barium enema examination and to determine at what point in the examination changes are likely to occur. METHODS AND RESULTS: Blood pressure measurements were taken at seven points during the course of barium enema examination in 107 consecutive patients. We found that patients over the age of 60 years had statistically significant decreases in blood pressure when they were stood up during the course of the examination. Many of these patients were asymptomatic. Patients who had symptoms (15/107, 14%) when standing up had a degree of hypotension. The duration of barium enema examination is longer in those patients who experience symptoms. CONCLUSION: During a barium enema examination hypotension occurs at the point of standing up more frequently in patients over 60 years and in those who suffer symptoms at this time. Patients who fall into one of these groups should be considered at risk of fainting at this point in the examination. A modified technique to avoid standing should be considered in at-risk patients. Roach, S.C. et al. (2001)

  10. Microalbuminuria Measured by three Different Methods, Blood Pressure and Cardiovascular Risk Factors in Elderly Swedish Males

    Directory of Open Access Journals (Sweden)

    Gösta Florvall

    2008-01-01

    Full Text Available Microalbuminuria is associated with hypertension and is a strong risk factor for subsequent chronic disease, both renal and coronary heart disease (CHD, Presently there are several methods available for measurement of microalbuminuria. The aim of this study was to evaluate if the three different methods gave similar information or if one of the assays were superior to the others. Blood pressure, inflammatory markers and cardiovascular mortality and morbidity were correlated with urine albumin analysed with a point-of-care testing (POCT instrument, nephelometric determination of albumin and albumin/creatinine ratio in elderly males. The study population consisted of 103 diabetic and 603 nondiabetic males (age 77 years in a cross-sectional study. We analyzed urine albumin with a HemoCue® Urine Albumin POCT instrument and a ProSpec® nephelometer and albumin/creatinine ratio. There were strong correlations between both systolic and diastolic blood pressure and all three urine albumin methods (p < 0.0001. There were also significant correlations between the different urine albumin measurements and serum amyloid A component, high-sensitivity C-reactive protein and interleukin-6. The three different urine albumin methods studied provided similar information in relation to cardiovascular disease. There was a strong correlation between systolic and diastolic blood pressure and microalbuminuria in both the whole study population and in nondiabetic males emphasizing the role of hypertension in glomerular damage. The good correlation between the studied urine albumin measurements show that all three methods can be used for monitoring urine albumin excretion.

  11. Endurance training in mild hypertension - effects on ambulatory blood pressure and neural circulatory control.

    Science.gov (United States)

    Narkiewicz; Somers

    1997-10-01

    This review examines the effects of a single bout of exercise and of endurance training on blood pressure in patients with hypertension. Possible autonomic mechanisms that mediate these changes in blood pressure are reviewed briefly. Blood pressure rises during exercise. During the second half hour after exercise blood pressure is lower. This p;ost-exercise reduction in blood pressure is associated with a decrease in muscle sympathetic nerve activity, an increase in baroreflex gain and a reduction in the level of blood pressure (set point) at which baroreflex activation occurs. The post-exercise fall in blood pressure appears to be limited to several hours and is not likely to explain any chronic reduction in blood pressure from endurance training. Endurance training elicits modest (approximately 4-5 mmHg) reductions in blood pressure. Because of the intrinsic variability of blood pressure, the decreases in blood pressure after endurance training is evident, especially when multiple measurements of blood pressure are obtained. Studies using 24 h blood pressure measurements suggest that, although endurance training lowers daytime blood pressure, blood pressure during sleep remains unchanged. The mechanism underlying the reduction in blood pressure in endurance training is not known. Although physical fitness is known to attenuate the sympathetic response to acute exercise, whether resting sympathetic drive is decreased with endurance training remains controversial. The slowing of heart rate that accompanies endurance training is also associated with an increase in variability of heart rate. The slower heart rate, increased variability of heart rate and lower blood pressure after endurance training are accompanied by an increase in baroreflex sensitivity. Even though the antihypertensive effect of endurance training is modest, the favourable effects of physical fitness on other risk factors for cardiovascular disease make exercise training an important approach in

  12. Does the position or contact pressure of the stethoscope make any difference to clinical blood pressure measurements: an observational study.

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-12-01

    This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP.

  13. Seaweed intake and blood pressure levels in healthy pre-school Japanese children

    Directory of Open Access Journals (Sweden)

    Yamamoto Keiko

    2011-08-01

    Full Text Available Abstract Background Few studies have examined whether dietary factors might affect blood pressure in children. We purposed to investigate whether seaweed intake is associated with blood pressure level among Japanese preschool children. Methods The design of the study was cross-sectional and it was conducted in autumn 2006. Subjects were healthy preschoolers aged 3-6 years in Aichi, Japan. Blood pressure and pulse were measured once by an automated sphygmomanometer, which uses oscillometric methods. Dietary data, including seaweed intake, were assessed using 3-day dietary records covering 2 consecutive weekdays and 1 weekend day. Of a total of 533 children, 459 (86.1 percent agreed to be enrolled in our study. Finally, blood pressure measurement, complete dietary records and parent-reported height and weight were obtained for 223 boys and 194 girls. Results When we examined Spearman's correlation coefficients, seaweed intake was significantly negatively related to systolic blood pressure in girls (P = 0.008. In the one-way analysis of covariance for blood pressure and pulse after adjustments for age and BMI, the boys with the lowest, middle and highest tertiles of seaweed intake had diastolic blood pressure readings of 62.8, 59.3 and 59.6 mmHg, respectively (P = 0.11, trend P = 0.038. Girls with higher seaweed intake had significantly lower systolic blood pressure readings (102.4, 99.2 and 96.9 mmHg for girls with the lowest, middle and highest tertiles of seaweed intake, respectively; P = 0.037, trend P = 0.030. Conclusion Our study showed that seaweed intake was negatively related to diastolic blood pressure in boys and to systolic blood pressure in girls. This suggests that seaweed might have beneficial effects on blood pressure among children.

  14. Secular trends of blood pressure in A-bomb survivors

    International Nuclear Information System (INIS)

    Sasaki, Hideo; Kodama, Kazunori; Kitano, Koei

    1986-01-01

    There has been controversy about whether or not radiation exposure plays a major role in advancing age. To preliminarily study this relationship, a statistical analysis was made on blood pressure measurements in a cohort of A-bomb survivors for Adult Health Study carried out during a 22-year period from 1958 through 1980. Systolic blood pressure increased with advancing age in both men and women between 30 and 80 years. During the years 1974 through 1980, it tended to increase in both men and women aged in their thirties and fourties. Diastolic blood pressure for men increased between the ages of 30 and 60 years, and decreased between the ages of 60 and 80 years. It tended to increase from year to year for men. For women, it decreased prior to the 1970's, and thereafter, tended to increase. The parameters, including systolic and diastolic blood pressures and pulse pressure, were independent of exposure doses in the subgroups according to age or sex. (Namekawa, K.)

  15. Child Abuse, Resting Blood Pressure, and Blood Pressure Reactivity to Psychosocial Stress.

    Science.gov (United States)

    Gooding, Holly C; Milliren, Carly E; Austin, S Bryn; Sheridan, Margaret A; McLaughlin, Katie A

    2016-01-01

    Childhood trauma is associated with hypertension in adults. It is unknown whether childhood trauma predicts elevated blood pressure earlier in development. We investigated whether the trauma of child abuse was associated with blood pressure in adolescents. The sample included 145 adolescents aged 13-17 years, 40% with exposure to child abuse. The mean age of participants was 14.93 years (SD = 1.33); 58% were female. The majority self-identified as non-Hispanic White (43%), with the remainder identifying as non-Hispanic Black (17%), Hispanic (17%), or other/mixed race (23%). We used established age/sex/height-specific cutoffs to determine the prevalence of prehypertension and hypertension in the sample. We used two-sample t tests to examine associations of abuse with resting systolic blood pressure (SBP) and diastolic blood pressure (DBP) and blood pressure reactivity to the Trier Social Stress Test and a frustration task. We used linear regression to adjust for potential confounders including sociodemographic variables, body mass index, smoking, and psychopathology. Mean resting SBP and DBP were 114.07 mmHg and 61.35 mmHg in those with a history of abuse and 111.39 mmHg and 56.89 mmHg in those without a history of abuse. This difference was significant for DBP only. Twelve percent of participants met criteria for prehypertension or hypertension based on resting blood pressure values; this did not differ between those with and without an abuse history. Child abuse was associated with lower DBP and SBP reactivity to laboratory stress tasks and reduced DBP reactivity to frustration. These associations were robust to adjustment for potential confounders. Child abuse is associated with higher resting DBP and blunted DBP and SBP reactivity to laboratory stress in adolescence. These findings suggest a potential pathway by which child abuse leads to hypertension. © The Author 2015. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All

  16. Association of PNC, BC, and PM2.5 Measured at a Central Monitoring Site with Blood Pressure in a Predominantly Near Highway Population

    Directory of Open Access Journals (Sweden)

    Mei Chung

    2015-03-01

    Full Text Available Elevated blood pressure is an indicator of cardiovascular stress and increased risk of cardiovascular-related morbidity and mortality. There is emerging evidence suggesting air pollutants, including particulate matter (PM, could promote hypertension, thereby increasing cardiovascular disease risk. Repeated measurement analyses were conducted to examine the associations of three types of PM with systolic blood pressure (SBP, diastolic blood pressure (DBP, and pulse pressure (PP in 220 participants, (mean age = 58.5 years from the Community Assessment of Freeway Exposure and Health study (CAFEH, most of whom live near a major highway. Ambient levels of air pollutants including particle number concentration (PNC; a measure of ultrafine particle (UFP concentration, fine PM (PM2.5, Particle diameter <2.5 µm, and black carbon (BC were measured at a central site <7 km from the study areas. Central sites are good at capturing short-term temporal trends in pollution associated with meteorological changes over regional areas. Linear mixed-effect models that accounted for repeated measures within one person were used to examine the associations between blood pressure variables and daily average of ambient PNC, PM2.5, or BC, controlling for demographic characteristics and major confounders including temperature. Our PNC model predicted that a higher PNC of 10,000 particles/cm3 was associated with higher DBP of 2.40 mmHg (p = 0.03, independent of other factors in the model. There were no significant associations for PM2.5 or BC. Post hoc subgroup analyses by obesity status showed that positive associations of DBP with PNC were more pronounced among obese individuals than non-obese individuals. These results suggested that PNC levels are associated with increased blood pressure, which may contribute to cardiovascular disease risk. More research is needed to assess the relationship between PNC and blood pressure and to address possible residual confounding.

  17. Home Monitoring of Blood Pressure: Patients' Perception and Role ...

    African Journals Online (AJOL)

    measuring devices, patients' emotional response to their blood pressure readings and actions taken in response. ... pressure, their response regarding different readings, and the .... pivotal position for providing pharmaceutical care services ...

  18. 21 CFR 870.1100 - Blood pressure alarm.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...

  19. Prevalence of end-digit preference in recorded blood pressure by ...

    African Journals Online (AJOL)

    2012-03-15

    Mar 15, 2012 ... Original Research: Prevalence of end-digit preference in recorded blood pressure by nurses. 73. Vol 55 No 1. S Afr Fam Pract 2013. Introduction. The accurate measurement and recording of blood pressure (BP) is critical to many processes. These include the diagnosis of hypertension, the decision to start.

  20. Association between ambient temperature and blood pressure and blood pressure regulators: 1831 hypertensive patients followed up for three years.

    Directory of Open Access Journals (Sweden)

    Qing Chen

    Full Text Available Several studies have suggested an association between ambient air temperature and blood pressure. However, this has not been reliably confirmed by longitudinal studies. Also, whether the reaction to temperature stimulation is modified by other factors such as antihypertensive medication is rarely investigated. The present study explores the relationship between ambient temperature and blood pressure, without and with antihypertensive medication, in a study of 1,831 hypertensive patients followed up for three years, in two or four weekly check ups, accumulating 62,452 follow-up records. Both baseline and follow-up blood pressure showed an inverse association with ambient temperature, which explained 32.4% and 65.6% of variation of systolic blood pressure and diastolic blood pressure (P<0.05 respectively. The amplitude of individual blood pressure fluctuation with temperature throughout a year (a 29 degrees centigrade range was 9.4/7.3 mmHg. Medication with angiotensin converting enzyme inhibitor benazepril attenuated the blood pressure fluctuation by 2.4/1.3 mmHg each year, though the inverse association of temperature and blood pressure remained. Gender, drinking behavior and body mass index were also found to modify the association between temperature and diastolic blood pressure. The results indicate that ambient temperature may negatively regulate blood pressure. Hypertensive patients should monitor and treat blood pressure more carefully in cold days, and it could be especially important for the males, thinner people and drinkers.

  1. Different systolic blood pressure targets for people with history of stroke or transient ischaemic attack: PAST-BP (Prevention After Stroke—Blood Pressure) randomised controlled trial

    Science.gov (United States)

    McManus, Richard J; Roalfe, Andrea; Fletcher, Kate; Taylor, Clare J; Martin, Una; Virdee, Satnam; Greenfield, Sheila; Hobbs, F D Richard

    2016-01-01

    Objective To assess whether using intensive blood pressure targets leads to lower blood pressure in a community population of people with prevalent cerebrovascular disease. Design Open label randomised controlled trial. Setting 99 general practices in England, with participants recruited in 2009-11. Participants People with a history of stroke or transient ischaemic attack whose systolic blood pressure was 125 mm Hg or above. Interventions Intensive systolic blood pressure target (different target, patients in both arms were actively managed in the same way with regular reviews by the primary care team. Main outcome measure Change in systolic blood pressure between baseline and 12 months. Results 529 patients (mean age 72) were enrolled, 266 to the intensive target arm and 263 to the standard target arm, of whom 379 were included in the primary analysis (182 (68%) intensive arm; 197 (75%) standard arm). 84 patients withdrew from the study during the follow-up period (52 intensive arm; 32 standard arm). Mean systolic blood pressure dropped by 16.1 mm Hg to 127.4 mm Hg in the intensive target arm and by 12.8 mm Hg to 129.4 mm Hg in the standard arm (difference between groups 2.9 (95% confidence interval 0.2 to 5.7) mm Hg; P=0.03). Conclusions Aiming for target below 130 mm Hg rather than 140 mm Hg for systolic blood pressure in people with cerebrovascular disease in primary care led to a small additional reduction in blood pressure. Active management of systolic blood pressure in this population using a blood pressure. Trial registration Current Controlled Trials ISRCTN29062286. PMID:26919870

  2. Prospective clinical study to evaluate an oscillometric blood pressure monitor in pet rabbits.

    Science.gov (United States)

    Bellini, Luca; Veladiano, Irene A; Schrank, Magdalena; Candaten, Matteo; Mollo, Antonio

    2018-02-27

    Rabbits are particularly sensitive to develop hypotension during sedation or anaesthesia. Values of systolic or mean non-invasive arterial blood pressure below 80 or 60 mmHg respectively are common under anaesthesia despite an ongoing surgery. A reliable method of monitoring arterial blood pressure is extremely important, although invasive technique is not always possible due to the anatomy and dimension of the artery. The aim of this study was to evaluate the agreement between a new oscillometric device for non-invasive arterial blood pressure measurement and the invasive method. Moreover the trending ability of the device, ability to identify changes in the same direction with the invasive methods, was evaluated as well as the sensibility of the device in identifying hypotension arbitrarily defined as invasive arterial blood pressure below 80 or 60 mmHg. Bland-Altman analysis for repeated measurements showed a poor agreement between the two methods; the oscillometric device overestimated the invasive arterial blood pressure, particularly at high arterial pressure values. The same analysis repeated considering oscillometric measurement that match invasive mean pressure lower or equal to 60 mmHg showed a decrease in biases and limits of agreement between methods. The trending ability of the device, evaluated with both the 4-quadrant plot and the polar plot was poor. Concordance rate of mean arterial blood pressure was higher than systolic and diastolic pressure although inferior to 90%. The sensibility of the device in detecting hypotension defined as systolic or mean invasive arterial blood pressure lower than 80 or 60 mmHg was superior for mean oscillometric pressure rather than systolic. A sensitivity of 92% was achieved with an oscillometric measurement for mean pressure below 65 mmHg instead of 60 mmHg. Non-invasive systolic blood pressure is less sensitive as indicator of hypotension regardless of the cutoff limit considered. Although mean invasive

  3. High Blood Pressure in Pregnancy

    Science.gov (United States)

    ... of the baby. Controlling your blood pressure during pregnancy and getting regular prenatal care are important for ... your baby. Treatments for high blood pressure in pregnancy may include close monitoring of the baby, lifestyle ...

  4. High blood pressure - medicine-related

    Science.gov (United States)

    Drug-induced hypertension is high blood pressure caused by using a chemical substance or medicine. ... of the arteries There are several types of high blood pressure : Essential hypertension has no cause that can be ...

  5. Pressure passive cerebral blood flow and breakdown of the blood-brain barrier in experimental fetal asphyxia

    DEFF Research Database (Denmark)

    Lou, H C; Lassen, N A; Tweed, W A

    1979-01-01

    reaching CBF values up to 6 times normal at normal MABP of about 60 to 70 mmHg, and severe ischemia reaching CBF values close to zero in large cortical areas at MABP of 30 mmHg. CVP remained essentially unchanged at 10--15 mmHg. The severe and prolonged asphyxia rendered the blood-brain barrier leaky......Cerebral blood flow (CBF) was studied in non-exteriorized near-term sheep fetuses using the radioactive microsphere technique. By partially occluding the umbilical vessels for a period of 1--1 1/2 hours a progressive and severe asphyxia with a final arterial pH of 6.90 was achieved. Varying...... the mean arterial blood pressure in the fetuses by blood withdrawal or infusion in this state, CBF was measured at different perfusion pressures (mean arterial blood pressure (MABP) minus central venous pressure (CVP)). A passive flow/pressure relationship--loss of autoregulation--was found, with hyperemia...

  6. Worldwide trends in blood pressure from 1975 to 2015: a pooled analysis of 1479 population-based measurement studies with 19·1 million participants.

    Science.gov (United States)

    2017-01-07

    Raised blood pressure is an important risk factor for cardiovascular diseases and chronic kidney disease. We estimated worldwide trends in mean systolic and mean diastolic blood pressure, and the prevalence of, and number of people with, raised blood pressure, defined as systolic blood pressure of 140 mm Hg or higher or diastolic blood pressure of 90 mm Hg or higher. For this analysis, we pooled national, subnational, or community population-based studies that had measured blood pressure in adults aged 18 years and older. We used a Bayesian hierarchical model to estimate trends from 1975 to 2015 in mean systolic and mean diastolic blood pressure, and the prevalence of raised blood pressure for 200 countries. We calculated the contributions of changes in prevalence versus population growth and ageing to the increase in the number of adults with raised blood pressure. We pooled 1479 studies that had measured the blood pressures of 19·1 million adults. Global age-standardised mean systolic blood pressure in 2015 was 127·0 mm Hg (95% credible interval 125·7-128·3) in men and 122·3 mm Hg (121·0-123·6) in women; age-standardised mean diastolic blood pressure was 78·7 mm Hg (77·9-79·5) for men and 76·7 mm Hg (75·9-77·6) for women. Global age-standardised prevalence of raised blood pressure was 24·1% (21·4-27·1) in men and 20·1% (17·8-22·5) in women in 2015. Mean systolic and mean diastolic blood pressure decreased substantially from 1975 to 2015 in high-income western and Asia Pacific countries, moving these countries from having some of the highest worldwide blood pressure in 1975 to the lowest in 2015. Mean blood pressure also decreased in women in central and eastern Europe, Latin America and the Caribbean, and, more recently, central Asia, Middle East, and north Africa, but the estimated trends in these super-regions had larger uncertainty than in high-income super-regions. By contrast, mean blood pressure might have increased in east and southeast

  7. Blood pressure standards for Saudi children and adolescents

    International Nuclear Information System (INIS)

    AlSalloum, Abdullah A.; El Mouzan, Mohammad I.; AlHerbish, Abdullah S.; AlOmar, Ahmad A.; Qurashi, Mansour M.

    2009-01-01

    Blood pressure levels may vary in children because of genetic, ethnic and socioeconomic factors. To date, there have been no large national studies in Saudi Arabia on blood pressure in children. Therefore, we sought to establish representative blood pressure reference centiles for Saudi Arabian children and adolescents. We selected a sample of children and adolescents aged from birth to 18 years by multi-stage probability sampling of the Saudi population. The selected sample represented Saudi children from the whole country. Data were collected through a house-to-house survey of all selected households in all 13 regions in the country. Data were analyzed to study the distribution pattern of systolic (SBP) and diastolic blood pressure (DBP) and to develop reference values. The 90th percentile of SBP and DBP values for each age were compared with values from a Turkish and an American study. A total of 16 226 Saudi children and adolescents from birth to 18 years were studied. Blood pressure rose steadily with age in both boys and girls. The average annual increase in SBP was 1.66 mm Hg for boys and1.44 mm Hg for girls. The average annual increase in DBP was 0.83 mm Hg for boys and 0.77 mm Hg for girls. DBP rose sharply in boys at the age of 18 years. Values for the 90th percentile of both SBP and DBP varied in Saudi children from their Turkish and American counterparts for all age groups. Blood pressure values in this study differed from those from other studies in developing countries and in the United States, indicating that comparison across studies is difficult and from that every population should use their own normal standards to define measured blood pressure levels in children. (author)

  8. The hidden magnitude of raised blood pressure and elevated blood ...

    African Journals Online (AJOL)

    Conclusions: The prevalence of undiagnosed raised blood pressure and elevated blood sugar was high in Ethiopia and only very small percentage of people had been aware of their high blood pressure and elevated blood sugar. Policy makers in the health sector including other health development partners need to ...

  9. Dysglycemia induces abnormal circadian blood pressure variability

    Directory of Open Access Journals (Sweden)

    Kumarasamy Sivarajan

    2011-11-01

    Full Text Available Abstract Background Prediabetes (PreDM in asymptomatic adults is associated with abnormal circadian blood pressure variability (abnormal CBPV. Hypothesis Systemic inflammation and glycemia influence circadian blood pressure variability. Methods Dahl salt-sensitive (S rats (n = 19 after weaning were fed either an American (AD or a standard (SD diet. The AD (high-glycemic-index, high-fat simulated customary human diet, provided daily overabundant calories which over time lead to body weight gain. The SD (low-glycemic-index, low-fat mirrored desirable balanced human diet for maintaining body weight. Body weight and serum concentrations for fasting glucose (FG, adipokines (leptin and adiponectin, and proinflammatory cytokines [monocyte chemoattractant protein-1 (MCP-1 and tumor necrosis factor-α (TNF-α] were measured. Rats were surgically implanted with C40 transmitters and blood pressure (BP-both systolic; SBP and diastolic; DBP and heart rate (HR were recorded by telemetry every 5 minutes during both sleep (day and active (night periods. Pulse pressure (PP was calculated (PP = SBP-DBP. Results [mean(SEM]: The AD fed group displayed significant increase in body weight (after 90 days; p Conclusion These data validate our stated hypothesis that systemic inflammation and glycemia influence circadian blood pressure variability. This study, for the first time, demonstrates a cause and effect relationship between caloric excess, enhanced systemic inflammation, dysglycemia, loss of blood pressure control and abnormal CBPV. Our results provide the fundamental basis for examining the relationship between dysglycemia and perturbation of the underlying mechanisms (adipose tissue dysfunction induced local and systemic inflammation, insulin resistance and alteration of adipose tissue precursors for the renin-aldosterone-angiotensin system which generate abnormal CBPV.

  10. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices.

    Science.gov (United States)

    Martina, Jerson R; Westerhof, Berend E; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F M; de Mol, Bas A J M; Lahpor, Jaap R

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean ± SD) of systolic, diastolic, mean, and pulse pressures were -7.6 ± 5.8, -7.0 ± 5.2, -6.9 ± 5.1, and -0.6 ± 4.5 mm Hg, respectively (all blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)max (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)max (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)max during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.

  11. Validation of Transtek blood pressure monitor TMB-1491 for self-measurement according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Tian, Huiyong; Zeng, Sijian; Zhong, Xiaoyan; Gong, Wei; Liu, Wenjun

    2015-10-01

    Transtek blood pressure monitor TMB-1491 is an automatic upper arm device designed for self/home measurement in adult populations. This study aimed to evaluate its accuracy according to the European Society of Hypertension International Protocol revision 2010. The protocol requirements were followed precisely with the recruitment of 33 adult individuals on whom same-left-arm sequential systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements were obtained in this study (three pairs for each of the 33 participants). The device produced 74, 95 and 99 measurements within 5, 10, and 15 mmHg for SBP and 85, 97, and 99 for DBP, respectively. The mean±SD device-observer difference was -0.6±4.4 mmHg for SBP and -0.6±3.4 mmHg for DBP. The number of participants with two or three device-observer difference within 5 mmHg was 24 for SBP and 29 for DBP. In addition, none of the participants had a device-observer difference within 5 mmHg for SBP, and three of the participants had the same for DBP. Transtek TMB-1491 has passed all phases of European Society of Hypertension International Protocol revision 2010 and can be recommended for self/home measurement in adult populations.

  12. Blood pressure monitors for home

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007482.htm Blood pressure monitors for home To use the sharing features ... may ask you to keep track of your blood pressure at home. To do this, you will need ...

  13. Comparison study of upper arm and forearm non-invasive blood pressures in adult Emergency Department patients.

    Science.gov (United States)

    Schimanski, Karen; Jull, Andrew; Mitchell, Nancy; McLay, Jessica

    2014-12-01

    Forearm blood pressures have been suggested as an alternative site to measure blood pressures when the upper arm is unavailable. However there is little evidence utilising clinical populations to support this substitution. To determine agreement between blood pressures measured in the left upper arm and forearm using a singular oscillometric non-invasive device in adult Emergency Department patients. The secondary objective was to explore the relationship of blood pressure differences with age, sex, ethnicity, smoking history and obesity. Single centre comparison study. Adult Emergency Department, Tertiary Trauma Centre. Forty-four participants who met inclusion/exclusion criteria selected sequentially from the Emergency Department arrival board. A random assignment of order of measurement for left upper arm and forearm blood pressures was utilised. Participants were eligible if they were aged 18 years or older, had been assigned an Australasian Triage Scale code of 2, 3, 4, or 5, were able to consent, and able to have blood pressures measured on their left arm whilst lying at a 45° angle. The Bland-Altman method of statistical analysis was used, with the level of agreement for clinical acceptability for the systolic, diastolic and mean arterial pressure defined as ±10 mmHg. The forearm measure overestimated systolic (mean difference 2.2 mmHg, 95% limits of agreement ±19 mmHg), diastolic (mean difference 3.4 mmHg, 95% limits of agreement ±14.4 mmHg), and mean arterial pressures (mean difference 4.1 mmHg, 95% limits of agreement ±13.7 mmHg). The systolic measure was not significantly different from zero. Evidence of better agreement was found with upper arm/forearm systolic measures below 140 mmHg compared to systolic measures above 140 mmHg using the Levene's test (p=0.002, F-statistic=11.09). Blood pressure disparity was not associated with participant characteristics. Forearm measures cannot routinely replace upper arm measures for blood pressure measurement

  14. Perceived unfairness at work, social and personal resources, and resting blood pressure.

    Science.gov (United States)

    Ford, Michael T

    2014-02-01

    By drawing from theoretical perspectives suggesting that unfair conditions threaten fundamental psychological needs, perceived unfairness at work was proposed and tested as a predictor of resting blood pressure. As part of the Midlife Development in the United States Biomarkers project, participants completed questionnaires measuring perceived unfairness, self-esteem and coworker support. Resting blood pressure readings were also recorded as part of a larger physical examination. Results indicate that perceived unfairness at work was associated with higher resting diastolic and systolic blood pressure. Perceived unfairness was most strongly related to diastolic and systolic blood pressure among women with low levels of coworker support. Contrary to predictions, self-esteem did not moderate the association between perceived unfairness and blood pressure. These results suggest that high blood pressure may be a mechanism linking unfairness to negative health outcomes and point to coworker support as a moderator of the perceived unfairness-blood pressure relationship among women. Further research is needed exploring the mediating mechanisms linking unfair treatment at work to blood pressure and health. Copyright © 2013 John Wiley & Sons, Ltd.

  15. Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor.

    Science.gov (United States)

    Stens, Jurre; Oeben, Jeroen; Van Dusseldorp, Ab A; Boer, Christa

    2016-10-01

    Nexfin beat-to-beat arterial blood pressure monitoring enables continuous assessment of hemodynamic indices like cardiac index (CI), pulse pressure variation (PPV) and stroke volume variation (SVV) in the perioperative setting. In this study we investigated whether Nexfin adequately reflects alterations in these hemodynamic parameters during a provoked fluid shift in anesthetized and mechanically ventilated patients. The study included 54 patients undergoing non-thoracic surgery with positive pressure mechanical ventilation. The provoked fluid shift comprised 15° Trendelenburg positioning, and fluid responsiveness was defined as a concomitant increase in stroke volume (SV) >10 %. Nexfin blood pressure measurements were performed during supine steady state, Trendelenburg and supine repositioning. Hemodynamic parameters included arterial blood pressure (MAP), CI, PPV and SVV. Trendelenburg positioning did not affect MAP or CI, but induced a decrease in PPV and SVV by 3.3 ± 2.8 and 3.4 ± 2.7 %, respectively. PPV and SVV returned back to baseline values after repositioning of the patient to baseline. Bland-Altman analysis of SVV and PPV showed a bias of -0.3 ± 3.0 % with limits of agreement ranging from -5.6 to 6.2 %. The SVV was more superior in predicting fluid responsiveness (AUC 0.728) than the PVV (AUC 0.636), respectively. The median bias between PPV and SVV was different for patients younger [-1.5 % (-3 to 0)] or older [+2 % (0-4.75)] than 55 years (P < 0.001), while there were no gender differences in the bias between PPV and SVV. The Nexfin monitor adequately reflects alterations in PPV and SVV during a provoked fluid shift, but the level of agreement between PPV and SVV was low. The SVV tended to be superior over PPV or Eadyn in predicting fluid responsiveness in our population.

  16. Epidural blood patch for refractory low CSF pressure headache

    DEFF Research Database (Denmark)

    Madsen, Søren Aalbæk; Fomsgaard, Jonna Storm; Jensen, Rigmor

    2011-01-01

    primary effect parameter was total headache burden defined as area under the curve (AUC: intensity × duration) and as secondary effect parameters we identified: intensity (VAS 0-10), frequency (days per month), duration in hours (total hours/month) and also medication days (days on medication...... of non-invasive/conservative measures and invasive measures with epidural blood patch providing the cornerstone of the invasive measures. In the present pilot study we therefore aimed to evaluate the treatment efficacy of epidural blood patch (EBP) in treatment-refractory low-pressure headache. Our......Once believed an exceedingly rare disorder, recent evidence suggests that low cerebrospinal fluid (CSF) pressure headache has to be considered an important cause of new daily persistent headaches, particularly among young and middle-aged individuals. Treatment of low CSF pressure headache consists...

  17. Epidural blood patch for refractory low CSF pressure headache

    DEFF Research Database (Denmark)

    Madsen, Søren Aalbæk; Fomsgaard, Jonna Storm; Jensen, Rigmor

    2011-01-01

    of non-invasive/conservative measures and invasive measures with epidural blood patch providing the cornerstone of the invasive measures. In the present pilot study we therefore aimed to evaluate the treatment efficacy of epidural blood patch (EBP) in treatment-refractory low-pressure headache. Our......Once believed an exceedingly rare disorder, recent evidence suggests that low cerebrospinal fluid (CSF) pressure headache has to be considered an important cause of new daily persistent headaches, particularly among young and middle-aged individuals. Treatment of low CSF pressure headache consists...... primary effect parameter was total headache burden defined as area under the curve (AUC: intensity × duration) and as secondary effect parameters we identified: intensity (VAS 0-10), frequency (days per month), duration in hours (total hours/month) and also medication days (days on medication...

  18. Association between blood pressure and Alzheimer disease measured up to 27 years prior to diagnosis: the HUNT Study.

    Science.gov (United States)

    Gabin, Jessica Mira; Tambs, Kristian; Saltvedt, Ingvild; Sund, Erik; Holmen, Jostein

    2017-05-31

    A lot of attention has been paid to the relationship of blood pressure and dementia because epidemiological research has reported conflicting evidence. Observational data has shown that midlife hypertension is a risk factor for cognitive decline and dementia later in life, whereas there is evidence that low blood pressure is predictive in later life. The aim of the present study was to examine the association between dementia and blood pressure measured up to 27 years (mean 17.6 years) prior to ascertainment. In Nord-Trøndelag County, Norway, incident dementia data were collected during 1995-2011, and the diagnoses were validated by a panel of experts in the field. By using the subjects' personal identification numbers, the dementia data were linked to data from the Nord-Trøndelag Health Study (the HUNT Study), a large, population-based health study performed in 1984-1986 (HUNT 1) and 1995-1997 (HUNT 2). A total of 24,638 participants of the HUNT Study were included in the present study, 579 of whom were diagnosed with Alzheimer disease, mixed Alzheimer/vascular dementia, or vascular dementia. Multiple logistic regression analyses were conducted to analyze the association between dementia and blood pressure data from HUNT 1 and HUNT 2. Over the age of 60 years, consistent inverse associations were observed between systolic blood pressure and all-cause dementia, mixed Alzheimer/vascular dementia, and Alzheimer disease, but not with vascular dementia, when adjusting for age, sex, education, and other relevant covariates. This was observed for systolic blood pressure in both HUNT 1 and HUNT 2, regardless of antihypertensive medication use. There was an adverse association between systolic blood pressure, pulse pressure, and Alzheimer disease in individuals treated with antihypertensive medication under the age of 60 years. Our data are in line with those in previous studies demonstrating an inverse association between dementia and systolic blood pressure in

  19. Genetic influence on blood pressure measured in the office, under laboratory stress and during real life

    NARCIS (Netherlands)

    Wang, Xiaoling; Ding, Xiuhua; Su, Shaoyong; Harshfield, Gregory; Treiber, Frank; Snieder, Harold

    To determine to what extent the genetic influences on blood pressure (BP) measured in the office, under psychologically stressful conditions in the laboratory and during real life are different from each other. Office BP, BP during a video game challenge and a social stressor interview, and 24-h

  20. From pioneering to implementing automated blood pressure measurement in clinical practice: Thomas Pickering's legacy

    DEFF Research Database (Denmark)

    Stolarz-Skrzypek, Katarzyna; Thijs, Lutgarde; Wizner, Barbara

    2010-01-01

    Thomas G. Pickering spent most of his scientific career in carrying out research on clinical hypertension and blood pressure (BP) measurement. In our review of Pickering's seminal work, we first focused on white-coat hypertension and masked hypertension, two terms that he had introduced. Next, we...... highlighted the early publications of Pickering on diurnal BP variability and on the clinical application of self-measured BP. Pickering's work inspired many investigators worldwide and constituted a solid basis for further research. Pickering's original ideas led to algorithms for risk stratification...

  1. Common High Blood Pressure Myths

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Common High Blood Pressure Myths Updated:May 4,2018 Knowing the facts ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  2. Blood Pressure vs. Heart Rate

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Blood Pressure vs. Heart Rate (Pulse) Updated:Nov 13,2017 ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  3. Medications for High Blood Pressure

    Science.gov (United States)

    ... Consumers Home For Consumers Consumer Updates Medications for High Blood Pressure Share Tweet Linkedin Pin it More sharing options ... age and you cannot tell if you have high blood pressure by the way you feel, so have your ...

  4. High blood pressure and diet

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007483.htm High blood pressure and diet To use the sharing features on ... diet is a proven way to help control high blood pressure . These changes can also help you lose weight ...

  5. Blood Pressure Management in Cardiovascular Risk Stratification. Procedure, Progression, Process.

    NARCIS (Netherlands)

    Adiyaman, A.

    2009-01-01

    In this thesis we have explored different aspects of blood pressure measurement and related it to the risk of cardiovascular disease. In the first part we showed that when the arm is positioned under heart level, for example when the arm is placed on a desk or a chair support, the blood pressure and

  6. Walnut consumption in a weight reduction intervention: effects on body weight, biological measures, blood pressure and satiety.

    Science.gov (United States)

    Rock, Cheryl L; Flatt, Shirley W; Barkai, Hava-Shoshana; Pakiz, Bilge; Heath, Dennis D

    2017-12-04

    Dietary strategies that help patients adhere to a weight reduction diet may increase the likelihood of weight loss maintenance and improved long-term health outcomes. Regular nut consumption has been associated with better weight management and less adiposity. The objective of this study was to compare the effects of a walnut-enriched reduced-energy diet to a standard reduced-energy-density diet on weight, cardiovascular disease risk factors, and satiety. Overweight and obese men and women (n = 100) were randomly assigned to a standard reduced-energy-density diet or a walnut-enriched (15% of energy) reduced-energy diet in the context of a behavioral weight loss intervention. Measurements were obtained at baseline and 3- and 6-month clinic visits. Participants rated hunger, fullness and anticipated prospective consumption at 3 time points during the intervention. Body measurements, blood pressure, physical activity, lipids, tocopherols and fatty acids were analyzed using repeated measures mixed models. Both study groups reduced body weight, body mass index and waist circumference (time effect p weight was -9.4 (0.9)% vs. -8.9 (0.7)% (mean [SE]), for the standard vs. walnut-enriched diet groups, respectively. Systolic blood pressure decreased in both groups at 3 months, but only the walnut-enriched diet group maintained a lower systolic blood pressure at 6 months. The walnut-enriched diet group, but not the standard reduced-energy-density diet group, reduced total cholesterol and low-density lipoprotein cholesterol (LDL-C) at 6 months, from 203 to 194 mg/dL and 121 to 112 mg/dL, respectively (p weight loss that is comparable to a standard reduced-energy-density diet in the context of a behavioral weight loss intervention. Although weight loss in response to both dietary strategies was associated with improvements in cardiovascular disease risk factors, the walnut-enriched diet promoted more favorable effects on LDL-C and systolic blood pressure. The trial

  7. Blood pressure change does not associate with Center of Pressure movement after postural transition in geriatric outpatients

    NARCIS (Netherlands)

    Timmermans, Sjoerd T.; Reijnierse, Esmee M.; Pasma, J.H.; Trappenburg, Marijke C.; Blauw, Gerard J.; Maier, Andrea B.; Meskers, Carel G M

    2018-01-01

    Background: Orthostatic hypotension (OH), a blood pressure drop after postural change, is associated with impaired standing balance and falls in older adults. This study aimed to assess the association between blood pressure (BP) and a measure of quality of standing balance, i.e. Center of

  8. Inter-arm blood pressure differences compared with ambulatory monitoring: a manifestation of the 'white-coat' effect?

    Science.gov (United States)

    Martin, Una; Holder, Roger; Hodgkinson, James; McManus, Richard

    2013-02-01

    Inter-arm difference in blood pressure of >10 mmHg is associated with peripheral vascular disease, but it is unclear how much of the difference in sequential right and left arm blood pressure measurements might be due to a 'white-coat' effect. To use ambulatory blood pressure monitoring (ABPM) to better understand the clinical significance of inter-arm differences in blood pressure. Retrospective study in a teaching hospital in Birmingham. Anonymised clinical data collected from 784 patients attending a single hospital-based hypertension clinic were retrospectively analysed. Each participant had blood pressure measured sequentially in both arms, followed by ABPM over the subsequent 24 hours. Data were available for 710 (91%) patients, of whom 39.3% (279) had a blood pressure difference of 10 mmHg or more between each arm. Compared to daytime systolic ABPM, the difference was 25.1 mmHg using the arm with the highest reading, but only 15.5 mmHg if the lower reading was taken (mean difference 9.6 mmHg (95% confidence interval [CI] = 9.0 mmHg to 10.3 mmHg)). However, differences between mean right (20.7 mmHg) or left (19.9 mmHg) arm blood pressure and daytime systolic ABPM were very similar. Compared with ABPM, use of the higher of the left and right arm readings measured sequentially appears to overestimate true mean blood pressure. As there is no significant difference in the extent of disparity with ABPM by left or right arm, this is unlikely to be due to arm dominance and may be due to the 'white-coat' effect reducing blood pressure on repeated measurement. Where a large inter-arm blood pressure difference is detected with sequential measurement, healthcare professionals should re-measure the blood pressure in the original arm.

  9. Noise exposure at school and blood pressure in adolescents

    Directory of Open Access Journals (Sweden)

    Fadhilah Ihsani

    2017-01-01

    Full Text Available Background The increasing prevalence of primary hypertension has motivated researchers to identify influencing factors, one of which is noise. There have been few studies on a relationships between noise exposure and blood pressure in children, and none have dealt exclusively with adolescents. Objective To assess for an association between noise exposure at school and blood pressure in adolescents.   Methods To identify noisy and quiet schools, the mean noise levels of 192 senior high schools in Medan were measured using sound level meters. One noisy school and one quiet school were randomly selected for inclusion (mean noise levels of  68.2 and  53.8 dB, respectively. Students from both schools underwent blood pressure measurements by mercury sphygmomanometer. Their Body weights and heights were obtained for body mass index calculations. Subjects filled questionnaires and their parents were interviewed regarding history of illnesses. Results Of the 271 adolescents recruited, 136 (50.2% were from the noisy school. Adolescents from the noisy school had higher mean systolic and diastolic blood pressures [121.6 (SD 13.87 mmHg and 71.1 (SD 8.15 mmHg, respectively], than those from the quiet school [111.8 (SD 12.61 mmHg and 63.8 (SD 8.05 mmHg, respectively]. After adjusting for other factors, noise had a significant, moderate, positive association with systolic and diastolic blood pressures [β = 0.452; B = 6.21 (95% CI 3.86-8.55 mmHg; and β = 0.473; B = 4.18 (95% CI 2.41 to 5.94 mmHg, respectively]. Conclusion Adolescents from a noisy school have a greater risk of higher systolic and diastolic blood pressures than those from a quiet school.

  10. A blood pressure monitor with robust noise reduction system under linear cuff inflation and deflation.

    Science.gov (United States)

    Usuda, Takashi; Kobayashi, Naoki; Takeda, Sunao; Kotake, Yoshifumi

    2010-01-01

    We have developed the non-invasive blood pressure monitor which can measure the blood pressure quickly and robustly. This monitor combines two measurement mode: the linear inflation and the linear deflation. On the inflation mode, we realized a faster measurement with rapid inflation rate. On the deflation mode, we realized a robust noise reduction. When there is neither noise nor arrhythmia, the inflation mode incorporated on this monitor provides precise, quick and comfortable measurement. Once the inflation mode fails to calculate appropriate blood pressure due to body movement or arrhythmia, then the monitor switches automatically to the deflation mode and measure blood pressure by using digital signal processing as wavelet analysis, filter bank, filter combined with FFT and Inverse FFT. The inflation mode succeeded 2440 measurements out of 3099 measurements (79%) in an operating room and a rehabilitation room. The new designed blood pressure monitor provides the fastest measurement for patient with normal circulation and robust measurement for patients with body movement or severe arrhythmia. Also this fast measurement method provides comfortableness for patients.

  11. Evaluation of the impact of atmospheric pressure in different seasons on blood pressure in patients with arterial hypertension.

    Science.gov (United States)

    Kamiński, Marek; Cieślik-Guerra, Urszula I; Kotas, Rafał; Mazur, Piotr; Marańda, Witold; Piotrowicz, Maciej; Sakowicz, Bartosz; Napieralski, Andrzej; Trzos, Ewa; Uznańska-Loch, Barbara; Rechciński, Tomasz; Kurpesa, Małgorzata

    2016-01-01

    Atmospheric pressure is the most objective weather factor because regardless of if outdoors or indoors it affects all objects in the same way. The majority of previous studies have used the average daily values of atmospheric pressure in a bioclimatic analysis and have found no correlation with blood pressure changes. The main objective of our research was to assess the relationship between atmospheric pressure recorded with a frequency of 1 measurement per minute and the results of 24-h blood pressure monitoring in patients with treated hypertension in different seasons in the moderate climate of the City of Łódź (Poland). The study group consisted of 1662 patients, divided into 2 equal groups (due to a lower and higher average value of atmospheric pressure). Comparisons between blood pressure values in the 2 groups were performed using the Mann-Whitney U test. We observed a significant difference in blood pressure recorded during the lower and higher range of atmospheric pressure: on the days of the spring months systolic (p = 0.043) and diastolic (p = 0.005) blood pressure, and at nights of the winter months systolic blood pressure (p = 0.013). A significant inverse relationship between atmospheric pressure and blood pressure during the spring days and, only for systolic blood pressure, during winter nights was observed. Int J Occup Med Environ Health 2016;29(5):783-792. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  12. Severe obesity and high blood pressure among children, Philadelphia health centers, 2010.

    Science.gov (United States)

    Nguyen, John V; Robbins, Jessica M; Houck, Kevin L; Nobis, Elizabeth A; Inman, Katelyn A; Khan, Khudsiya S; Robbins, Susan W

    2014-04-01

    Child obesity is a major health problem particularly affecting disadvantaged population groups. Severe obesity carries additional health risks for children. In the context of the childhood obesity epidemic, high blood pressure among children is of increasing concern. Chart reviews were carried out to examine the prevalence of severe obesity and its association with high blood pressure measurements among randomly selected patients aged 3 to 17 years who had well-child care visits at 8 public community health centers during 2010. A majority of the 691 patients reviewed were African American (58%); an additional 16% were Hispanic. The prevalence of severe obesity was 7.7% (95% confidence interval = 5.8% to 9.9%) and the prevalence of high blood pressure measurements was 17.5% (95% confidence interval = 14.8% to 20.6%). Patients who were severely obese were more than twice as likely as other children to have high blood pressure values. Severe obesity is associated with substantially increased frequency of high blood pressure measurements in children, and should be investigated further as a potential marker for hypertension in children. Primary care providers should be prepared to diagnose and treat hypertension in severely obese children.

  13. Use of home blood-pressure monitoring in the detection, treatment and surveillance of hypertension.

    Science.gov (United States)

    Manning, Gillian; Donnelly, Richard

    2005-11-01

    Use of home blood-pressure monitoring is increasing but the technique and the equipment have limitations. We provide an overview of recent evidence in this rapidly evolving field. Home blood-pressure monitoring is an acceptable method for screening patients for hypertension. There is increasing evidence supporting the predictive power of home blood pressure for stroke risk even in the general population. The identification of white-coat and masked hypertension remains an important role for home blood-pressure monitoring. Unvalidated equipment and poor patient technique are major concerns. The purchase of devices needs to be linked to a simple patient-education programme, which is perhaps an opportunity for collaboration between healthcare providers and commercial companies. Devices that store the blood-pressure measurements in the memory are preferred to ensure accuracy of reporting. Data-transmission systems providing automatic storage, transmission and reporting of blood pressure, direct involvement of the patient and potentially a reduced number of hospital/general practitioner visits, offer significant advantages. To reduce patient anxiety, overuse of home blood-pressure monitoring should be avoided but there is the potential for self-modification of treatment, subject to certain safeguards. Self-monitoring of blood pressure is developing rapidly, linked to increasing awareness of the impact of reducing high blood pressure on public health and the marketing/advertising strategies used to sell automatic devices. Home blood-pressure monitoring has a role in the detection and management of blood pressure, but not at the expense of careful blood-pressure measurement in the office and adherence to national guidelines.

  14. The association between smoking and blood pressure in men: a cross-sectional study.

    Science.gov (United States)

    Li, Guoju; Wang, Hailing; Wang, Ke; Wang, Wenrui; Dong, Fen; Qian, Yonggang; Gong, Haiying; Hui, Chunxia; Xu, Guodong; Li, Yanlong; Pan, Li; Zhang, Biao; Shan, Guangliang

    2017-10-10

    Cigarette smoking is a known risk factor for cardiovascular disease (CVD), but the association between smoking and blood pressure is unclear. Thus, the current study examined the association between cigarette smoking and blood pressure in men. Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP) and pulse pressure (PP) were examined using digital blood pressure measuring device, and smoking status was determined with China National Health Survey. The ANCOVA showed that the adjusted DBP and MAP were lower in current smokers versus nonsmokers and the adjusted SBP was lower in current smokers versus former smokers (P smoking on blood pressure indices except PP was observed. Smoking cessation was significantly associated with an increased risk of hypertension. However, current smoking was not a risk factor of hypertension.

  15. Blood Pressure Drugs and AMD

    Science.gov (United States)

    ... Patient Stories Español Eye Health / News Research News: Blood Pressure Drugs and AMD Leer en Español: Noticias de ... also found an association between AMD and high blood pressure, but this has been inconsistent. To help clarify ...

  16. What Is High Blood Pressure?

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More What is High Blood Pressure? Updated:Feb 27,2018 First, let’s define high ... resources . This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  17. Inter-Arm Difference in Brachial Blood Pressure in the General Population of Koreans.

    Science.gov (United States)

    Song, Bo Mi; Kim, Hyeon Chang; Shim, Jee-Seon; Lee, Myung Ha; Choi, Dong Phil

    2016-05-01

    We investigated the inter-arm difference in blood pressure of the general Korean population to identify associated factors. A total of 806 participants aged 30 to 64 years without history of major cardiovascular disease were analyzed in this cross-sectional study. They participated in the Cardiovascular and Metabolic Disease Etiology Research Center cohort study that began in 2013. Brachial blood pressure was measured simultaneously for both arms using an automated oscillometric device equipped with two cuffs in seated position. After five minutes of rest, systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured three times. The average of the three measurements was used for analysis. Multivariate logistic regression models were used to identify factors associated with inter-arm differences in blood pressure. The mean inter-arm difference was 3.3 mmHg for SBP and 2.0 mmHg for DBP. Large inter-arm differences (≥10 mmHg) in SBP and in DBP were found in 3.7% and 0.9% of subjects, respectively. A large inter-arm difference in SBP was associated with mean SBP (p=0.002) and C-reactive protein (p=0.014) while a large inter-arm different in DBP was only associated with body mass index (p=0.015). Sex, age, and anti-hypertensive medication use were not associated with differences in inter-arm blood pressure. Large inter-arm difference in blood pressure is only present in a small portion of healthy Korean adults. Our findings suggest that high SBP, chronic inflammation, and obesity may be associated with larger difference in inter-arm blood pressure.

  18. Improvement of a sensor unit for wrist blood pressure monitoring system

    Science.gov (United States)

    Koo, Sangjun; Kwon, Jongwon; Park, Yongman; Ayuzenara, Odgerel; Kim, Hiesik

    2007-12-01

    A blood pressure sensor unit for ubiquitous healthcare monitoring was newly developed. The digital wrist band-type blood pressure devices for home are popular already in the market. It is useful for checking blood pressure level at home and control of hypertension. Especially, it is very essential home device to check the health condition of blood circulation disease. Nowadays many product types are available. But the measurement of blood pressure is not accurate enough compared with the mechanical type. It needs to be upgraded to assure the precise health data enough to use in the hospital. The structure, feature and output signal of capacitor type pressure sensors are analyzed. An improved design of capacitor sensor is suggested. It shows more precise health data after use on a wrist band type health unit. They can be applied for remote u-health medical service.

  19. A pressão arterial está sendo medida? Is the blood pressure being measured?

    Directory of Open Access Journals (Sweden)

    Débora C. Alavarce

    2000-03-01

    Full Text Available A medida da pressão arterial faz parte do exame físico e deve ser realizada em toda consulta médica. Para avaliar se a pressão arterial é medida nas consultas médicas, foram consultados 500 prontuários de pacientes de primeira consulta ambulatorial, sendo 335 (67% provenientes de clínicas médicas e cirúrgicas e 165 (33% das clínicas ginecológica e obstétrica. A pressão arterial foi anotada em 39% das consultas realizadas (135±32/85±19 mm Hg, sendo que em 11% destas anotações a pressão diastólica estava acima de 90 mm Hg. Em relação ao diagnóstico prévio de hipertensão arterial verificou-se que: a em 62% dos prontuários não havia esta informação; b 20% referiram ter hipertensão, e em 79% destes a pressão arterial foi anotada; e c 18% referiram não ter hipertensão e 46% destes tiveram registro da pressão arterial. Portanto, a maior parte dos pacientes não teve sua pressão arterial anotada.The blood pressure measure is part of the physical exam and it should be accomplished in every medical consultation. To verify the blood pressure measured in the accomplished medical consultations record of first they were consulted it consults 500 patient's ambulatorial being 335 (67% coming of medical and surgical clinics and 165 (33% of the gynecological and obstetric clinics. The blood pressure was written down in 39% of the accomplished consultations (135+32 mm Hg 85+19 mm Hg, and 11% of this annotations the pressure diastólica was above 90 mm Hg. In relation to the previous diagnosis of hypertension it was verified that: a in 62% of the records there was not this information; b 20% referred to have hypertension, and in 79% of these the arterial pressure was scored; and c 18% referred not to have hypertension and 46% of these had registration of the arterial pressure. Therefore, most of the patients didn't have its logged arterial pressure.

  20. High blood pressure and eye disease

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000999.htm High blood pressure and eye disease To use the sharing features on this page, please enable JavaScript. High blood pressure can damage blood vessels in the retina . The ...

  1. Miniaturized Blood Pressure Telemetry System with RFID Interface

    Directory of Open Access Journals (Sweden)

    Michele Caldara

    2016-08-01

    Full Text Available This work deals with the development and characterization of a potentially implantable blood pressure telemetry system, based on an active Radio-Frequency IDentification (RFID tag, International Organization for Standardization (ISO 15693 compliant. This approach aims to continuously measure the average, systolic and diastolic blood pressure of the small/medium animals. The measured pressure wave undergoes embedded processing and results are stored onboard in a non-volatile memory, providing the data under interrogation by an external RFID reader. In order to extend battery lifetime, RFID energy harvesting has been investigated. The paper presents the experimental characterization in a laboratory and preliminary in-vivo tests. The device is a prototype mainly intended, in a future engineered version, for monitoring freely moving test animals for pharmaceutical research and drug safety assessment purposes, but it could have multiple uses in environmental and industrial applications.

  2. High blood pressure and visual sensitivity

    Science.gov (United States)

    Eisner, Alvin; Samples, John R.

    2003-09-01

    The study had two main purposes: (1) to determine whether the foveal visual sensitivities of people treated for high blood pressure (vascular hypertension) differ from the sensitivities of people who have not been diagnosed with high blood pressure and (2) to understand how visual adaptation is related to standard measures of systemic cardiovascular function. Two groups of middle-aged subjects-hypertensive and normotensive-were examined with a series of test/background stimulus combinations. All subjects met rigorous inclusion criteria for excellent ocular health. Although the visual sensitivities of the two subject groups overlapped extensively, the age-related rate of sensitivity loss was, for some measures, greater for the hypertensive subjects, possibly because of adaptation differences between the two groups. Overall, the degree of steady-state sensitivity loss resulting from an increase of background illuminance (for 580-nm backgrounds) was slightly less for the hypertensive subjects. Among normotensive subjects, the ability of a bright (3.8-log-td), long-wavelength (640-nm) adapting background to selectively suppress the flicker response of long-wavelength-sensitive (LWS) cones was related inversely to the ratio of mean arterial blood pressure to heart rate. The degree of selective suppression was also related to heart rate alone, and there was evidence that short-term changes of cardiovascular response were important. The results suggest that (1) vascular hypertension, or possibly its treatment, subtly affects visual function even in the absence of eye disease and (2) changes in blood flow affect retinal light-adaptation processes involved in the selective suppression of the flicker response from LWS cones caused by bright, long-wavelength backgrounds.

  3. Anxiety: A Cause of High Blood Pressure?

    Science.gov (United States)

    ... of high blood pressure? Can anxiety cause high blood pressure? Answers from Sheldon G. Sheps, M.D. Anxiety doesn't cause long-term high blood pressure (hypertension). But episodes of anxiety can cause dramatic, ...

  4. Definition of hypertension: the impact of number of visits for blood pressure measurement.

    Science.gov (United States)

    Figueiredo, Daniela; Azevedo, Ana; Pereira, Marta; de Barros, Henrique

    2009-01-01

    A diagnosis of hypertension should be based on multiple blood pressure (BP) measurements, taken on at least two separate occasions. We aimed to assess the impact of considering different criteria for a definition of hypertension, based on number of visits for blood pressure measurement, on estimates of hypertension prevalence, awareness, treatment and control, and on its association with two variables definitely related to hypertension: body mass index and left ventricular hypertrophy. We used data from a cross-sectional study of 739 participants, aged > or = 45 years, randomly selected from a non-institutionalized Portuguese population, from January 2001 to December 2003. Main outcome measures were prevalence of hypertension (systolic BP > or = 140 mmHg and/or diastolic BP > or = 90 mmHg or current antihypertensive drug therapy) based on BP measurements on one visit, on BP measurements on a second visit or on fulfilling the same criteria on the two different visits. Estimated hypertension prevalence was 63.4% (95% CI: 59.8-66.9) using BP measurements from the first visit (HTN1) and 60.2% (95% CI: 56.6-63.8) using BP measurements from the second visit (HTN2). If both visits are used as criteria the estimated hypertension prevalence (HTN(Final)) was 56.3% (95% CI: 52.7-60.0), p (McNemar test) hypertension prevalence have a similar strong and independent association with body mass index (OR = 2.71 for body mass index > or = 30 with HTN(Final)) and with left ventricular hypertrophy (OR = 3.21 for HTN(Final) with left ventricular hypertrophy). In many individuals labeled as hypertensive on a single evaluation, hypertension was not confirmed on reassessment, leading to a significant overestimation of 12.6% of the true prevalence. For this reason BP should be measured on at least two office visits both for clinical purposes and in epidemiological studies. On the other hand, this did not reflect on the association between hypertension and body mass index or left

  5. Blood pressure patterns in women with gestational hypertension or mild preeclampsia at term.

    Science.gov (United States)

    van der Tuuk, K; Tajik, P; Koopmans, C M; van den Berg, P P; Mol, B W J; van Pampus, M G; Groen, H

    2017-03-01

    Gestational hypertension (GH) and mild preeclampsia (PE) represent the most common medical complications of pregnancy, with the majority of cases developing at or near term. There is little knowledge of the course of blood pressure over time in these women. We explored the pattern of systolic and diastolic blood pressure over time in women with GH or mild PE at term participating in the HYPITAT trial, and we attempted to identify clinical factors influencing these blood pressure patterns and the impact of severe hypertension on clinical management. We used data from the HYPITAT trial, that included women with a singleton pregnancy with a fetus in cephalic position between 36 and 41 weeks of gestation with the diagnosis of GH or mild PE. Blood pressure measurements were performed from randomization or admission until delivery or discharge from the hospital. We included the highest blood pressure of each day. We evaluated systolic and diastolic blood pressure change over time, as well as the influence of clinical characteristics and laboratory findings on the course of blood pressure. We used univariate and multivariate regression analysis with a backward stepwise algorithm for the selection of variables. The model with the best fit (lowest AIC) was selected as the final model. We also compared mode of delivery for women with and without severe hypertension. We studied 1076 women who had 4188 blood pressure measurements done. The systolic blood pressure showed a significant non-linear increase over time and for the diastolic blood pressure the pattern was also non-linear. In the multivariable model of systolic blood pressure change over time, nulliparity, ethnicity, systolic blood pressure (at baseline), BMI and LDH at randomization influenced the course of blood pressure. In the diastolic blood pressure model ALT and the baseline diastolic blood pressure had a significant influence. When we explored the association between blood pressure and mode of delivery, it

  6. Self-monitored blood pressure: a role in clinical practice?

    Science.gov (United States)

    Padfield, Paul L

    2002-02-01

    Electronic self-monitoring of blood pressure is increasing in popularity and most international guidelines on the management of hypertension approve cautious use of the technique in the assessment of potentially hypertensive individuals. A recent editorial in the Archives of Internal Medicine suggested that it was "appropriate to encourage the widespread use of self recorded BP as an important adjunct to the clinical care of the patient with hypertension". Such a statement is based on increasing evidence that self-monitoring of blood pressure gives similar information to daytime ambulatory blood pressure -- a now well-established technology in the management of hypertension. Suggested strategies for the use of self-monitoring of blood pressure include monitoring in individuals whose clinical risk status is low enough that they need not necessarily be given medical therapy simply on the basis of a clinic pressure (i.e. at a 10 year risk of cardiovascular disease below 20%). The threshold for defining 'normotension/hypertension' is now regarded as being broadly similar for ABPM and SBPM and is set at 135/85 mmHg. In a recent meta-analysis of all available studies the average difference between these techniques, using the same patients, is -1.7/1.2 mmHg. There is some evidence that careful use of self-monitoring may improve blood pressure control in patients who are otherwise resistant to care. Self-monitoring of blood pressure has now been shown in at least one major prospective study to predict outcome better than clinic pressures and in that setting it now has equivalence to the use of ABPM. There remain issues regarding the availability of validated devices, the quality of training of patients in their use and the possibility that inaccurate recording might occur, either deliberately or by accident. Self-monitoring of blood pressure may well not give the same readings as carefully measured blood pressure by research nurses but its use is clearly superior to

  7. Diabetes and blood pressure (image)

    Science.gov (United States)

    People with diabetes have a higher risk for heart attacks and strokes. Your doctor or nurse should check your blood pressure ... People with diabetes have a higher risk for heart attacks and strokes. Your doctor or nurse should check your blood pressure ...

  8. Impact of calibration on estimates of central blood pressures.

    Science.gov (United States)

    Soender, T K; Van Bortel, L M; Møller, J E; Lambrechtsen, J; Hangaard, J; Egstrup, K

    2012-12-01

    Using the Sphygmocor device it is recommended that the radial pressure wave is calibrated for brachial systolic blood pressure (SBP) and diastolic blood pressure (DBP). However it has been suggested that brachial-to-radial pressure amplification causes underestimation of central blood pressures (BPs) using this calibration. In the present study we examined if different calibrations had an impact on estimates of central BPs and on the clinical interpretation of our results. On the basis of ambulatory BP measurements, patients were categorized into patients with controlled, uncontrolled or resistant hypertension. We first calibrated the radial pressure wave as recommended and afterwards recalibrated the same pressure wave using brachial DBP and calculated mean arterial pressure. Recalibration of the pressure wave generated significantly higher estimates of central SBP (P=0.0003 and Plost in patients with resistant hypertension (P=0.15). We conclude that calibration with DBP and mean arterial pressure produces higher estimates of central BPs than recommended calibration. The present study also shows that this difference between the two calibration methods can produce more than a systematic error and has an impact on interpretation of clinical results.

  9. Validation of the Medipro MediCare 100f upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Yi, Jun; Wan, Yi; Pan, Feng; Yu, Xiaorong; Zhao, Huadong; Shang, Fujun; Xu, Yongyong

    2011-08-01

    The validation of sphygmomanometer is important in accurate blood pressure measurement. This study presents the validation results by the Medipro MediCare 100f upper arm blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. A total of 99 couples of test device and reference blood pressure measurements were obtained during the study (three pairs for each of the 33 participants). The device produced 73, 93, and 98 measurements within 5, 10, and 15 mmHg for systolic blood pressure (SBP) and 79, 93, and 96 for diastolic blood pressure (DBP), respectively. The mean standard deviation device-observer difference was 1.4 ± 5.2 mmHg for SBP and 0.02±5.8 mmHg for DBP. The number of participants with two or three of the device-observer differences within 5 mmHg was 24 for SBP and 30 for DBP, whereas there was no participant with none of the device-observer differences within 5 mmHg. According to the results of the validation study based on the ESH-IP revision 2010, the Medipro MediCare 100f can be recommended for self-measurement in an adult population.

  10. Social Stress Induced Pressure Breathing and Consequent Blood Pressure Oscillation

    NARCIS (Netherlands)

    Fokkema, Dirk S.; Koolhaas, Jaap M.; Meulen, Jan van der; Schoemaker, Regien

    1986-01-01

    A large amplitude blood pressure oscillation occurs during social defeat in a territorial fight between male rats, and during the application of a psychosocial stimulus associated with this defeat. Synchronous recording of blood pressure, intrathoracic pressure and diaphragm activity shows that the

  11. Maternal first-trimester dietary intake and childhood blood pressure: the Generation R Study.

    Science.gov (United States)

    van den Hil, Leontine C L; Rob Taal, H; de Jonge, Layla L; Heppe, Denise H M; Steegers, Eric A P; Hofman, Albert; van der Heijden, Albert J; Jaddoe, Vincent W V

    2013-10-01

    Suboptimal maternal dietary intake during pregnancy might lead to fetal cardiovascular adaptations and higher blood pressure in the offspring. The aim of the present study was to investigate the associations of maternal first-trimester dietary intake with blood pressure in children at the age of 6 years. We assessed first-trimester maternal daily dietary intake by a FFQ and measured folate, homocysteine and vitamin B₁₂ concentrations in the blood, in a population-based prospective cohort study among 2863 mothers and children. Childhood systolic and diastolic blood pressure was measured using a validated automatic sphygmomanometer. First-trimester maternal daily intake of energy, fat, protein and carbohydrate was not associated with childhood blood pressure. Furthermore, maternal intake of micronutrients was not associated with childhood blood pressure. Also, higher maternal vitamin B₁₂ concentrations were associated with a higher diastolic blood pressure (0·31 mmHg per standard deviation increase in vitamin B₁₂ (95% CI 0·06, 0·56)). After taking into account multiple testing, none of the associations was statistically significant. Maternal first-trimester folate and homocysteine concentrations were not associated with childhood blood pressure. The results from the present study suggest that maternal Fe intake and vitamin B₁₂ concentrations during the first trimester of pregnancy might affect childhood blood pressure, although the effect estimates were small and were not significant after correction for multiple testing. Further studies are needed to replicate these findings, to elucidate the underlying mechanisms and to assess whether these differences in blood pressure persist in later life.

  12. Associations of ambulatory blood pressure with urinary caffeine and caffeine metabolite excretions.

    Science.gov (United States)

    Guessous, Idris; Pruijm, Menno; Ponte, Belén; Ackermann, Daniel; Ehret, Georg; Ansermot, Nicolas; Vuistiner, Philippe; Staessen, Jan; Gu, Yumei; Paccaud, Fred; Mohaupt, Markus; Vogt, Bruno; Pechère-Bertschi, Antoinette; Pechère-Berstchi, Antoinette; Martin, Pierre-Yves; Burnier, Michel; Eap, Chin B; Bochud, Murielle

    2015-03-01

    Intake of caffeinated beverages might be associated with reduced cardiovascular mortality possibly via the lowering of blood pressure. We estimated the association of ambulatory blood pressure with urinary caffeine and caffeine metabolites in a population-based sample. Families were randomly selected from the general population of Swiss cities. Ambulatory blood pressure monitoring was conducted using validated devices. Urinary caffeine, paraxanthine, theophylline, and theobromine excretions were measured in 24 hours urine using ultrahigh performance liquid chromatography tandem mass spectrometry. We used mixed models to explore the associations of urinary excretions with blood pressure although adjusting for major confounders. The 836 participants (48.9% men) included in this analysis had mean age of 47.8 and mean 24-hour systolic and diastolic blood pressure of 120.1 and 78.0 mm Hg. For each doubling of caffeine excretion, 24-hour and night-time systolic blood pressure decreased by 0.642 and 1.107 mm Hg (both P values theobromine excretion was not associated with blood pressure. Anti-hypertensive therapy, diabetes mellitus, and alcohol consumption modify the association of caffeine urinary excretion with systolic blood pressure. Ambulatory systolic blood pressure was inversely associated with urinary excretions of caffeine and other caffeine metabolites. Our results are compatible with a potential protective effect of caffeine on blood pressure. © 2014 American Heart Association, Inc.

  13. Contributions of social context to blood pressure: findings from a multilevel analysis of social capital and systolic blood pressure.

    Science.gov (United States)

    Hamano, Tsuyoshi; Fujisawa, Yoshikazu; Yamasaki, Masayuki; Ito, Katsuhisa; Nabika, Toru; Shiwaku, Kuninori

    2011-06-01

    In recent years, few studies have quantified the effect of residential context on blood pressure. Although these studies have emphasized the importance of socioeconomic influences such as education or poverty levels, the association between the features of social structure such as social capital and blood pressure remain unclear. Therefore, we investigated whether social capital was associated with systolic blood pressure after controlling for individual potential confounders. We analyzed data from the Shimane Study conducted from 2006 to 2008 in rural mountainous regions of Japan. After excluding the missing data and data of participants taking hypertension medication, we conducted a multilevel analysis of the data for 335 individuals nested within 30 postcode sectors. Systolic blood pressure increased with increasing age and body mass index. We also found that a higher systolic blood pressure was observed among smokers and those taking medication for diabetes. Regarding the contextual effects of social capital, systolic blood pressure increased with an increasing proportion of lack of fairness, after adjustment for individual confounders. To the best of our knowledge, this study is the first to investigate the association between social capital and systolic blood pressure by using a multilevel methodological framework. Surprisingly, we found that lack of fairness had a strong effect on systolic blood pressure. However, we could not find any significant associations between other items of social capital and systolic blood pressure. Further studies are needed to clarify the mechanism by which lack of fairness may have an effect on systolic blood pressure.

  14. MEthods of ASsessing blood pressUre: identifying thReshold and target valuEs (MeasureBP): a review & study protocol.

    Science.gov (United States)

    Blom, Kimberly C; Farina, Sasha; Gomez, Yessica-Haydee; Campbell, Norm R C; Hemmelgarn, Brenda R; Cloutier, Lyne; McKay, Donald W; Dawes, Martin; Tobe, Sheldon W; Bolli, Peter; Gelfer, Mark; McLean, Donna; Bartlett, Gillian; Joseph, Lawrence; Featherstone, Robin; Schiffrin, Ernesto L; Daskalopoulou, Stella S

    2015-04-01

    Despite progress in automated blood pressure measurement (BPM) technology, there is limited research linking hard outcomes to automated office BPM (OBPM) treatment targets and thresholds. Equivalences for automated BPM devices have been estimated from approximations of standardized manual measurements of 140/90 mmHg. Until outcome-driven targets and thresholds become available for automated measurement methods, deriving evidence-based equivalences between automated methods and standardized manual OBPM is the next best solution. The MeasureBP study group was initiated by the Canadian Hypertension Education Program to close this critical knowledge gap. MeasureBP aims to define evidence-based equivalent values between standardized manual OBPM and automated BPM methods by synthesizing available evidence using a systematic review and individual subject-level data meta-analyses. This manuscript provides a review of the literature and MeasureBP study protocol. These results will lay the evidenced-based foundation to resolve uncertainties within blood pressure guidelines which, in turn, will improve the management of hypertension.

  15. Blood pressure and serum creatinine in obese female.

    Science.gov (United States)

    Asrin, M; Nessa, A; Hasan, M I; Das, R K

    2015-01-01

    Obesity is increasing in developed as well as in developing countries. This analytical cross sectional study was carried out to document the relation between blood pressure, serum creatinine and body mass index in female and to assess potential health differences among obese female and normal weight female. This study was done in the Department of Physiology, Mymensingh Medical College, Mymensingh, Bangladesh from July 2012 to June 2013. Seventy female persons volunteered as subjects. Among them 35 were within normal weight (BMI 18.5-24.9kg/m²) and 35 were obese (BMI≥30kg/m²). Non probability purposive type of sampling technique was used to select the subjects. Measurement of body mass index and blood pressure were done as per procedure. Serum creatinine level was estimated by enzymatic colorimetric method. The results were calculated and analyzed by using SPSS (statistical package for social science, version 17.0), scientific electronic calculator and simultaneously with a computer assisted program like Microsoft excel. Unpaired 't' test was applied to find the significance of difference regarding serum creatinine and blood pressure levels in obese female. The value of p was 1% to indicate highly significant and 5% to indicate simply significant or statistically significant. The mean±SE of systolic blood pressure, diastolic blood pressure and serum creatinine levels were 135.71±1.58mmHg, 88.74±0.95mmHg and 1.03±0.01mg/dl respectively; significant at 1% level for obese group of BMI (phigh BMI is significantly related to increased levels of serum creatinine & blood pressure in obese female which indicate the obese subjects are prone to cardiovascular & metabolic risk.

  16. Influence of partial pressure of oxygen in blood samples on measurement performance in glucose-oxidase-based systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-11-01

    Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Aliquots of 20 venous samples were adjusted to the following pO2 values: oxygen sensitive. © 2013 Diabetes Technology Society.

  17. Ambulatory Blood Pressure Monitoring in Clinical Practice: A Review

    Science.gov (United States)

    Viera, Anthony J.; Shimbo, Daichi

    2016-01-01

    Ambulatory blood pressure monitoring offers the ability to collect blood pressure readings several times an hour across a 24-hour period. Ambulatory blood pressure monitoring facilitates the identification of white-coat hypertension, the phenomenon whereby certain individuals who are not on antihypertensive medication show elevated blood pressure in a clinical setting but show non-elevated blood pressure averages when assessed by ambulatory blood pressure monitoring. Additionally, readings can be segmented into time windows of particular interest, e.g., mean daytime and nighttime values. During sleep, blood pressure typically decreases, or dips, such that mean sleep blood pressure is lower than mean awake blood pressure. A non-dipping pattern and nocturnal hypertension are strongly associated with increased cardiovascular morbidity and mortality. Approximately 70% of individuals dip ≥10% at night, while 30% have non-dipping patterns, when blood pressure remains similar to daytime average, or occasionally rises above daytime average. The various blood pressure categorizations afforded by ambulatory blood pressure monitoring are valuable for clinical management of high blood pressure since they increase accuracy for diagnosis and the prediction of cardiovascular risk. PMID:25107387

  18. What Physical Fitness Component Is Most Closely Associated With Adolescents' Blood Pressure?

    Science.gov (United States)

    Nunes, Heloyse E G; Alves, Carlos A S; Gonçalves, Eliane C A; Silva, Diego A S

    2017-12-01

    This study aimed to determine which of four selected physical fitness variables, would be most associated with blood pressure changes (systolic and diastolic) in a large sample of adolescents. This was a descriptive and cross-sectional, epidemiological study of 1,117 adolescents aged 14-19 years from southern Brazil. Systolic and diastolic blood pressure were measured by a digital pressure device, and the selected physical fitness variables were body composition (body mass index), flexibility (sit-and-reach test), muscle strength/resistance (manual dynamometer), and aerobic fitness (Modified Canadian Aerobic Fitness Test). Simple and multiple linear regression analyses revealed that aerobic fitness and muscle strength/resistance best explained variations in systolic blood pressure for boys (17.3% and 7.4% of variance) and girls (7.4% of variance). Aerobic fitness, body composition, and muscle strength/resistance are all important indicators of blood pressure control, but aerobic fitness was a stronger predictor of systolic blood pressure in boys and of diastolic blood pressure in both sexes.

  19. Ambulatory blood pressure monitoring in daily clinical practice - the Spanish ABPM Registry experience.

    Science.gov (United States)

    Gorostidi, Manuel; Banegas, José R; de la Sierra, Alejandro; Vinyoles, Ernest; Segura, Julián; Ruilope, Luis M

    2016-01-01

    Many patients are hypertensive at the medical settings but show normal blood pressure out of the doctor's office, and are classified as white-coat hypertensives. On the other hand, many patients with controlled hypertension at the clinic show ambulatory blood pressure levels above the thresholds considered for an adequate blood pressure control, known as having masked hypertension. Using data from the Spanish Ambulatory Blood Pressure Monitoring Registry (Spanish ABPM Registry), a national program developed to promote the use of the ambulatory technique for hypertension management in daily practice, we have reviewed the main strengths of this approach, that is the ability to detect discrepancies of blood pressure status with respect to office blood pressure measurement, and to better assess accurate rates of hypertension control. White-coat hypertension within patients with elevated office blood pressure, and masked hypertension within office-controlled patients affected one of three patients in each office status. On the other hand, rates of ambulatory blood pressure control (50%) doubled those of office blood pressure control (25%), still remaining half the patients uncontrolled. We think that a systematic use of ambulatory blood pressure monitoring, and strategies to improve blood pressure control constitute key priorities in hypertension management. © 2015 Stichting European Society for Clinical Investigation Journal Foundation.

  20. High Blood Pressure: Medicines to Help You

    Science.gov (United States)

    ... For Consumers Consumer Information by Audience For Women High Blood Pressure--Medicines to Help You Share Tweet Linkedin Pin ... Click here for the Color Version (PDF 533KB) High blood pressure is a serious illness. High blood pressure is ...

  1. Cerebral blood volume changes in cats with acute increased intracranial pressure

    International Nuclear Information System (INIS)

    Kondo, Takashi; Kano, Mitsumasa; Ikeda, Takuya.

    1984-01-01

    We measured the changes in cerebral blood volume in cats with increased intracranial pressure with a high-speed CT scanner, employing contrast effects by the iodine agent. In acute increased intracranial pressure caused by raising the extradural pressure by 20 mmHg, cerebral blood volume showed a significant decrease by 32% in comparison with that at normal intracranial pressure. There was also a tendency that a decline of iodine was delayed with time at increased intracranial pressure than that at normal pressure. This was supposed to be a delay of cerebral circulation due to venous congestion. This experimental model and measuring method provide the changes in CBV in the same individual without any tedious procedure, and therefore this is a reliable method with respect to precision. (author)

  2. Effect of overtime work on 24-hour ambulatory blood pressure.

    Science.gov (United States)

    Hayashi, T; Kobayashi, Y; Yamaoka, K; Yano, E

    1996-10-01

    Recently, the adverse effects of long working hours on the cardiovascular systems of workers in Japan, including "Karoshi" (death from overwork), have been the focus of social concern. However, conventional methods of health checkups are often unable to detect the early signs of such adverse effects. To evaluate the influence of overtime work on the cardiovascular system, we compared 24-hour blood pressure measurements among several groups of male white-collar workers. As a result, for those with normal blood pressure and those with mild hypertension, the 24-hour average blood pressure of the overtime groups was higher than that of the control groups; for those who periodically did overtime work, the 24-hour average blood pressure and heart rate during the busy period increased. These results indicate that the burden on the cardiovascular system of white-collar workers increases with overtime work.

  3. Quantitative and qualitative retinal microvascular characteristics and blood pressure.

    Science.gov (United States)

    Cheung, Carol Y; Tay, Wan T; Mitchell, Paul; Wang, Jie J; Hsu, Wynne; Lee, Mong L; Lau, Qiangfeng P; Zhu, Ai L; Klein, Ronald; Saw, Seang M; Wong, Tien Y

    2011-07-01

    The present study examined the effects of blood pressure on a spectrum of quantitative and qualitative retinal microvascular signs. Retinal photographs from the Singapore Malay Eye Study, a population-based cross-sectional study of 3280 (78.7% response) persons aged 40-80 years, were analyzed. Quantitative changes in the retinal vasculature (branching angle, vascular tortuosity, fractal dimension, and vascular caliber) were measured using a semi-automated computer-based program. Qualitative signs, including focal arteriolar narrowing (FAN), arteriovenous nicking (AVN), opacification of the arteriolar wall (OAW), and retinopathy (e.g., microaneurysms, retinal hemorrhages), were assessed from photographs by trained technicians. After excluding persons with diabetes and ungradable photographs, 1913 persons provided data for this analysis. In multivariable linear regression models controlling for age, sex, BMI, use of antihypertensive medication, and other factors, retinal arteriolar branching asymmetry ratio, arteriolar tortuosity, venular tortuosity, fractal dimension, arteriolar caliber, venular caliber, FAN, AVN, and retinopathy were independently associated with mean arterial blood pressure. In contrast, arteriolar/venular branching angle, venular branching asymmetry ratio and OAW were not related to blood pressure. Retinal arteriolar caliber (sβ = -0.277) and FAN (sβ = 0.170) had the strongest associations with mean arterial blood pressure, and higher blood pressure levels were associated with increasing number of both quantitative and qualitative retinal vascular signs (P trend qualitative retinal vascular signs, with the number of signs increasing with higher blood pressure levels.

  4. Validation of the SCIAN LD-735 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2016-08-01

    This study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor SCIAN LD-735 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were measured sequentially in 33 adult Chinese participants (10 women, mean age 44.8 years) using a mercury sphygmomanometer (two observers) and the SCIAN LD-735 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The SCIAN LD-735 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 86/99, 97/99, and 98/99, respectively, for systolic blood pressure and 85/99, 98/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. In total, 30 and 33 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The SCIAN wrist blood pressure monitor LD-735 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  5. Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2017-08-01

    The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (19 men, 45.7 years of mean age) using a mercury sphygmomanometer (two observers) and the AVITA BPM17 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM17 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 94/99, 98/99, and 98/99, respectively, for systolic blood pressure and 92/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Overall, 32 participants for both systolic and diastolic blood pressure, respectively, had at least two of the three device-observerss differences within 5 mmHg (required ≥24). None had all the three device-observers comparisons greater than 5 mmHg for systolic and diastolic blood pressure. The AVITA wrist blood pressure monitor BPM17 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  6. Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized camelids.

    Science.gov (United States)

    Aarnes, Turi K; Hubbell, John A E; Lerche, Phillip; Bednarski, Richard M

    2012-08-01

    This study assessed the accuracy of the oscillometric method for arterial blood pressure (ABP) monitoring in anesthetized camelids. Twenty camelids were anesthetized and systolic ABP (SABP), mean ABP (MABP), and diastolic ABP (DABP) were measured directly and using the oscillometric method. The mean difference between SABP measurements was -9.9 ± 21.9 mmHg with a range of -76 to 54 mmHg, and the 95% limits of agreement (LOA) were -33 to 53 mmHg. The difference between DABP measurements was -1.8 ± 15.6 mmHg with a range of -81 to 36 mmHg, and the 95% LOA were -32 to 29 mmHg. The difference between MABP measurements was -2.9 ± 17.0 mmHg with a range of -81 to 36 mmHg, and the 95% LOA were -30 to 36 mmHg. Accurate ABP monitoring in anesthetized camelids cannot be accomplished using the oscillometric method.

  7. Multicomponent exercise decreases blood pressure, heart rate and double product in normotensive and hypertensive older patients with high blood pressure.

    Science.gov (United States)

    Coelho-Júnior, Hélio José; Asano, Ricardo Yukio; Gonçalvez, Ivan de Oliveira; Brietzke, Cayque; Pires, Flávio Oliveira; Aguiar, Samuel da Silva; Feriani, Daniele Jardim; Caperuto, Erico Chagas; Uchida, Marco Carlos; Rodrigues, Bruno

    2018-02-26

    The present study aimed to investigate the effects of a 6-month multicomponent exercise program on blood pressure, heart rate, and double product of uncontrolled and controlled normotensive and hypertensive older patients. The study included 183 subjects, 97 normotensives, of which 53 were controlled normotensives (CNS), and 44 uncontrolled normotensives (UNS), as well as 86 hypertensives, of which 43 were controlled hypertensives (CHS), and 43 uncontrolled hypertensives (UHS). Volunteers were recruited and blood pressure and heart rate measurements were made before and after a 6-month multicomponent exercise program. The program of physical exercise was performed twice a week for 26 weeks. The physical exercises program was based on functional and walking exercises. Exercise sessions were performed at moderate intensity. The results indicated that UHS showed a marked decrease in systolic (-8.0mmHg), diastolic (-11.1mmHg), mean (-10.1mmHg), and pulse pressures, heart rate (-6.8bpm), and double product (-1640bpmmmHg), when compared to baseline. Similarly, diastolic (-5.5mmHg) and mean arterial (-4.8mmHg) pressures were significantly decreased in UNS. Concomitantly, significant changes could be observed in the body mass index (-0.9kg/m 2 ; -1.5kg/m 2 ) and waist circumference (-3.3cm; only UHS) of UNS and UHS, which may be associated with the changes observed in blood pressure. In conclusion, the data of the present study indicate that a 6-month multicomponent exercise program may lead to significant reductions in blood pressure, heart rate, and double product of normotensive and hypertensive patients with high blood pressure values. Copyright © 2018 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  8. High Blood Pressure - Multiple Languages

    Science.gov (United States)

    ... Being 8 - High Blood Pressure - Amarɨñña / አማርኛ (Amharic) MP3 Siloam Family Health Center Arabic (العربية) Expand Section ... Being 8 - High Blood Pressure - myanma bhasa (Burmese) MP3 Siloam Family Health Center Chinese, Simplified (Mandarin dialect) ( ...

  9. HIGH BLOOD PRESSURE: DOES THIS CONCERN ME?

    CERN Multimedia

    2007-01-01

    To find out, the Medical Service's nurses are organising A HIGH BLOOD PRESSURE SCREENING AND PREVENTION CAMPAIGN from Monday, 26th to Thursday, 29th March 2007 at the Infirmary - Building 57 - ground floor A blood pressure test, advice, information and, if necessary, referral for specialist medical treatment will be offered to any person working on the CERN site. High blood pressure is a silent threat to health. So come and get your blood pressure checked.

  10. HIGH BLOOD PRESSURE: DOES THIS CONCERN ME?

    CERN Multimedia

    2007-01-01

    To find out, the Medical Service's nurses are organising A HIGH BLOOD PRESSURE SCREENING AND PREVENTION CAMPAIGN from Monday, 26th to Thursday, 29th March 2007 at the Infirmary - Building 57 - ground floor A blood pressure test, advice, information and, if necessary, referral for specialist medical treatment will be offered to any person working on the CERN site. High blood pressure is a stealth threat to health. So come and get your blood pressure checked.

  11. Influence of sleep apnea severity on blood pressure variability of patients with hypertension.

    Science.gov (United States)

    Steinhorst, Ana P; Gonçalves, Sandro C; Oliveira, Ana T; Massierer, Daniela; Gus, Miguel; Fuchs, Sandra C; Moreira, Leila B; Martinez, Denis; Fuchs, Flávio D

    2014-05-01

    Obstructive sleep apnea (OSA) is a risk factor for the development of hypertension and cardiovascular disease. Apnea overloads the autonomic cardiovascular control system and may influence blood pressure variability, a risk for vascular damage independent of blood pressure levels. This study investigates the hypothesis that blood pressure variability is associated with OSA. In a cross-sectional study, 107 patients with hypertension underwent 24-h ambulatory blood pressure monitoring and level III polysomnography to detect sleep apnea. Pressure variability was assessed by the first derivative of blood pressure over time, the time rate index, and by the standard deviation of blood pressure measurements. The association between the apnea-hypopnea index and blood pressure variability was tested by univariate and multivariate methods. The 57 patients with apnea were older, had higher blood pressure, and had longer duration of hypertension than the 50 patients without apnea. Patients with apnea-hypopnea index (AHI) ≥ 10 had higher blood pressure variability assessed by the standard deviation than patients with AHI variability assessed by the time rate index presented a trend for association during sleep (P = 0.07). Daytime blood pressure variability was not associated with the severity of sleep apnea. Sleep apnea increases nighttime blood pressure variability in patients with hypertension and may be another pathway linking sleep abnormalities to cardiovascular disease.

  12. Effects of salt substitute on home blood pressure differs according to age and degree of blood pressure in hypertensive patients and their families.

    Science.gov (United States)

    Hu, Jihong; Zhao, Liancheng; Thompson, Brian; Zhang, Yawei; Wu, Yangfeng

    2018-02-05

    It is known that home blood pressure (HBP) is a more reliable assessment of hypertension treatments than clinical blood pressure (BP). Despite this, HBP response to a salt substitute has only been evaluated by one study which, did not look at the salt substitute's effect on family members and did not analyze by age, gender, or BP degree. The aim of this current study was to assess the effects of a low-sodium and high-potassium salt substitute on HBP among hypertensive patients and their family members. A total of 220 households (including 220 hypertensive patients and 380 their families) were randomly assigned to the regular salt or salt substitute groups. HBP was measured at the beginning, 3rd, 6th, and 12th months. Among the patients (n = 220), only home systolic blood pressure (HSBP) was significantly reduced, by an adjusted baseline BP of 4.2 mm Hg (95% CI: 1.3-7.0 mm Hg), in the salt substitute group compared with those in the regular salt group at each visit (all P blood pressure (HDBP) at any visit. Among the family members, HSBP and HDBP were not significantly different between the groups. Furthermore, Individuals ≥60 years old, hypertensive patients with stage-2 hypertension, family members with hypertension, and women experienced greater HSBP reduction. Older subjects, those with higher blood pressure, and women experienced greater home blood pressure reduction from the salt substitute compared to regular salt.

  13. Effects of hormone therapy on blood pressure.

    Science.gov (United States)

    Issa, Zeinab; Seely, Ellen W; Rahme, Maya; El-Hajj Fuleihan, Ghada

    2015-04-01

    Although hormone therapy remains the most efficacious option for the management of vasomotor symptoms of menopause, its effects on blood pressure remain unclear. This review scrutinizes evidence of the mechanisms of action of hormone therapy on signaling pathways affecting blood pressure and evidence from clinical studies. Comprehensive Ovid MEDLINE searches were conducted for the terms "hypertension" and either of the following "hormone therapy and menopause" or "selective estrogen receptor modulator" from year 2000 to November 2013. In vitro and physiologic studies did not reveal a clear deleterious effect of hormone therapy on blood pressure. The effect of oral therapy was essentially neutral in large trials conducted in normotensive women with blood pressure as primary outcome. Results from all other trials had several limitations. Oral therapy had a neutral effect on blood pressure in hypertensive women. Transdermal estrogen and micronized progesterone had a beneficial effect on blood pressure in normotensive women and, at most, a neutral effect on hypertensive women. In general, tibolone and raloxifene had a neutral effect on blood pressure in both hypertensive and normotensive women. Large randomized trials are needed to assess the effect of oral hormone therapy on blood pressure as a primary outcome in hypertensive women and the effect of transdermal preparations on both normotensive and hypertensive women. Transdermal preparations would be the preferred mode of therapy for hypertensive women, in view of their favorable physiologic and clinical profiles. The decision regarding the use of hormone therapy should be individualized, and blood pressure should be monitored during the course of treatment.

  14. Blood pressure regulation in diabetic autonomic neuropathy

    DEFF Research Database (Denmark)

    Hilsted, J

    1985-01-01

    Defective blood pressure responses to standing, exercise and epinephrine infusions have been demonstrated in diabetic patients with autonomic neuropathy. The circulatory mechanisms underlying blood pressure responses to exercise and standing up in these patients are well characterized: In both...... which may contribute to exercise hypotension in these patients. During hypoglycemia, blood pressure regulation seems intact in patients with autonomic neuropathy. This is probably due to release of substantial amounts of catecholamines during these experiments. During epinephrine infusions a substantial...... blood pressure fall ensues in patients with autonomic neuropathy, probably due to excessive muscular vasodilation. It is unresolved why blood pressure regulation is intact during hypoglycemia and severely impaired--at similar catecholamine concentrations--during epinephrine infusions....

  15. Thirty years of research on diagnostic and therapeutic thresholds for the self-measured blood pressure at home.

    NARCIS (Netherlands)

    Staessen, J.A.; Thijs, L.; Ohkubo, T.; Kikuya, M.; Richart, T.; Boggia, J.; Adiyaman, A.; Dechering, D.G.; Kuznetsova, T.; Thien, Th.; Leeuw, P. de; Imai, Y.; O'brien, E.; Parati, G.

    2008-01-01

    OBJECTIVE: The goal of this review study is to summarize 30 years of research on cut-off limits for the self-measured blood pressure. METHODS: We reviewed two meta-analyses, several prospective outcome studies in populations and hypertensive patients, studies in pregnant women, three clinical trials

  16. Inter-arm blood pressure differences compared with ambulatory monitoring: a manifestation of the ‘white-coat’ effect?

    Science.gov (United States)

    Martin, Una; Holder, Roger; Hodgkinson, James; McManus, Richard

    2013-01-01

    Background Inter-arm difference in blood pressure of >10 mmHg is associated with peripheral vascular disease, but it is unclear how much of the difference in sequential right and left arm blood pressure measurements might be due to a ‘white-coat’ effect. Aim To use ambulatory blood pressure monitoring (ABPM) to better understand the clinical significance of inter-arm differences in blood pressure. Design and setting Retrospective study in a teaching hospital in Birmingham. Method Anonymised clinical data collected from 784 patients attending a single hospital-based hypertension clinic were retrospectively analysed. Each participant had blood pressure measured sequentially in both arms, followed by ABPM over the subsequent 24 hours. Result Data were available for 710 (91%) patients, of whom 39.3% (279) had a blood pressure difference of 10 mmHg or more between each arm. Compared to daytime systolic ABPM, the difference was 25.1 mmHg using the arm with the highest reading, but only 15.5 mmHg if the lower reading was taken (mean difference 9.6 mmHg (95% confidence interval [CI] = 9.0 mmHg to 10.3 mmHg)). However, differences between mean right (20.7 mmHg) or left (19.9 mmHg) arm blood pressure and daytime systolic ABPM were very similar. Conclusion Compared with ABPM, use of the higher of the left and right arm readings measured sequentially appears to overestimate true mean blood pressure. As there is no significant difference in the extent of disparity with ABPM by left or right arm, this is unlikely to be due to arm dominance and may be due to the ‘white-coat’ effect reducing blood pressure on repeated measurement. Where a large inter-arm blood pressure difference is detected with sequential measurement, healthcare professionals should re-measure the blood pressure in the original arm. PMID:23561681

  17. Understanding Blood Pressure Readings

    Science.gov (United States)

    ... Venous Thromboembolism Aortic Aneurysm More Understanding Blood Pressure Readings Updated:Jun 1,2018 What do your blood ... and Live Our Interactive Cardiovascular Library has detailed animations and illustrations to help you learn about conditions, ...

  18. Blood pressure measurement method and inter-arm differences: a meta-analysis.

    Science.gov (United States)

    Verberk, Willem J; Kessels, Alfons G H; Thien, Theo

    2011-11-01

    Screening for inter-arm difference (IAD) of blood pressure (BP) at each first visit is recommended by numerous guidelines whereas it is unclear whether the method by which IAD is measured has significant influence on the IAD value. A systematic review is made of the studies reporting on double-arm measurements and the association of IAD with procedure characteristics (Medline/PubMed, Embase, and Cochrane Library). The mean absolute IAD was 5.4 ± 1.7 and 3.6 ± 1.2 mm Hg for systolic and diastolic BP, respectively. Of all subjects 14% had a systolic IAD ≥10 mm Hg, 4% a systolic IAD ≥20 mm Hg, and 7% a diastolic IAD ≥10 mm Hg. The relative risk (RR) of obtaining a systolic IAD ≥10 and 20 mm Hg and a diastolic IAD ≥10 mm Hg is higher when measuring sequentially instead of simultaneously (2.2 (95% CI: 1.4-3.6), P arms, with one or two automatic devices and multiple readings should be taken.

  19. Cuffless and Continuous Blood Pressure Estimation from the Heart Sound Signals

    Directory of Open Access Journals (Sweden)

    Rong-Chao Peng

    2015-09-01

    Full Text Available Cardiovascular disease, like hypertension, is one of the top killers of human life and early detection of cardiovascular disease is of great importance. However, traditional medical devices are often bulky and expensive, and unsuitable for home healthcare. In this paper, we proposed an easy and inexpensive technique to estimate continuous blood pressure from the heart sound signals acquired by the microphone of a smartphone. A cold-pressor experiment was performed in 32 healthy subjects, with a smartphone to acquire heart sound signals and with a commercial device to measure continuous blood pressure. The Fourier spectrum of the second heart sound and the blood pressure were regressed using a support vector machine, and the accuracy of the regression was evaluated using 10-fold cross-validation. Statistical analysis showed that the mean correlation coefficients between the predicted values from the regression model and the measured values from the commercial device were 0.707, 0.712, and 0.748 for systolic, diastolic, and mean blood pressure, respectively, and that the mean errors were less than 5 mmHg, with standard deviations less than 8 mmHg. These results suggest that this technique is of potential use for cuffless and continuous blood pressure monitoring and it has promising application in home healthcare services.

  20. Cuff inflation during ambulatory blood pressure monitoring and heart rate

    Directory of Open Access Journals (Sweden)

    Mia Skov-Madsen

    2008-11-01

    Full Text Available Mia Skov-Madsen, My Svensson, Jeppe Hagstrup ChristensenDepartment of Nephrology, Aarhus University Hospital, Aalborg, DenmarkIntroduction: Twenty four-hour ambulatory blood pressure monitoring is a clinically validated procedure in evaluation of blood pressure (BP. We hypothesised that the discomfort during cuff inflation would increase the heart rate (HR measured with 24-h ambulatory BP monitoring compared to a following HR measurement with a 24-h Holter monitor.Methods: The study population (n = 56 were recruited from the outpatient’s clinic at the Department of Nephrology, Aalborg Hospital, Aarhus University Hospital at Aalborg, Denmark. All the patients had chronic kidney disease (CKD. We compared HR measured with a 24-h Holter monitor with a following HR measured by a 24-h ambulatory BP monitoring.Results: We found a highly significant correlation between the HR measured with the Holter monitor and HR measured with 24-h ambulatory blood pressure monitoring (r = 0.77, p < 0.001. Using the Bland-Altman plot, the mean difference in HR was only 0.5 beat/min during 24 hours with acceptable limits of agreement for both high and low HR levels. Dividing the patients into groups according to betablocker treatment, body mass index, age, sex, angiotensin-converting enzyme inhibitor treatment, statins treatment, diuretic treatment, or calcium channel blocker treatment revealed similar results as described above.Conclusion: The results indicate that the discomfort induced by cuff inflation during 24-h ambulatory BP monitoring does not increase HR. Thus, 24-h ambulatory BP monitoring may be a reliable measurement of the BP among people with CKD.Keywords: ambulatory blood pressure monitoring, Holter monitoring, heart rate, chronic kidney disease, hypertension

  1. Relation of blood pressure and organ damage: comparison between feasible, noninvasive central hemodynamic measures and conventional brachial measures.

    Science.gov (United States)

    Lindroos, Annika S; Langén, Ville L; Kantola, Ilkka; Salomaa, Veikko; Juhanoja, Eeva P; Sivén, Sam S; Jousilahti, Pekka; Jula, Antti M; Niiranen, Teemu J

    2018-06-01

    The present cross-sectional study investigated whether central SBP and pulse pressure (PP) measured noninvasively with a novel cuff-based stand-alone monitor are more strongly associated with hypertensive end-organ damage than corresponding brachial measures. We investigated the cross-sectional association of central versus brachial SBP and PP with echocardiographic left ventricular mass index (LVMI), LV hypertrophy (LVH), carotid intima-media thickness (IMT), and increased IMT (IMT ≥ 75th percentile) among 246 participants drawn from the general population (mean age 57.2 years, 55.3% women). All blood pressure (BP) measures were positively correlated with LVMI and IMT (P area under curve (AUC) for SBP: 0.74 versus 0.76, P = 0.16; AUC for PP: 0.75 versus 0.73, P = 0.35] and IMT (AUC for SBP: 0.61 versus 0.61, P = 0.67; AUC for PP: 0.63 versus 0.61, P = 0.29). Our findings suggest that central SBP and PP measured with a stand-alone noninvasive BP monitor do not improve diagnostic accuracy for end-organ damage over corresponding brachial measures.

  2. Skin necrosis in a critically ill patient due to a blood pressure cuff

    Directory of Open Access Journals (Sweden)

    Devbhandari Mohan

    2006-01-01

    Full Text Available The non-invasive method of blood pressure measurement is regarded as a safe procedure and the reports of any serious complications are rare. We report a unique case of extensive skin necrosis due to an intermittently inflating blood pressure cuff in a 65-year-old critically ill lady following a third time redo mitral valve surgery. A brief review of the literature on complications associated with noninvasive method of measurement of blood pressure is presented along with possible mechanisms of skin injury and ways to avoid it.

  3. Twenty-four-hour blood pressure among Greenlanders and Danes: relationship to diet and lifestyle

    DEFF Research Database (Denmark)

    Jørgensen, Marit Eika; Pedersen, M.B.; Siggaard, Cecilie

    2002-01-01

    Greenlanders have a lower rate of cardiovascular mortality and morbidity than Danes, possibly due to lower blood pressure. However, 24-h blood pressure has never been measured in Greenlanders. The aim of this study was to compare the 24-h blood pressure of Greenlanders and Danes, and to analyse t...

  4. Effects of adrenalectomy, adrenal regeneration, and renal irradiation on blood pressure

    International Nuclear Information System (INIS)

    Rosenblum, M.; Casarett, G.W.

    1979-01-01

    Adrenalectomized, adrenal-enucleated and adrenal-intact rats were sham-irradiated or received an x-ray dose of 1100 rad bilaterally to temporarily exteriorized kidneys. Systolic blood pressures were measured at 10, 25, 40, 60, and 80 days after irradiation. At 100 days after irradiation the rats were sacrificed for gross pathologic examination and renal histopathologic studies of the kidneys. Adrenalectomy alone caused a significant drop in blood pressure which persisted throughout the experiment; adrenal regeneration in adrenal-enucleated rats or in those adrenalectomized rats in which adrenal tissue regenerated caused a significant increase in systolic blood pressure after 80 days postirradiation. Irradiation of adrenal-intact, adrenal-regenerating, or adrenalectomized rats did not cause significant elevation of blood pressure in comparison with that of the corresponding nonirradiated controls. Rats showing subtle renal histological changes usually showed somewhat higher blood pressures than rats showing no renal histological changes; a few rats which became severely hypertensive showed considerable histopathological changes in kidneys and other organs

  5. Measuring systolic arterial blood pressure. Possible errors from extension tubes or disposable transducer domes.

    Science.gov (United States)

    Rothe, C F; Kim, K C

    1980-11-01

    The purpose of this study was to evaluate the magnitude of possible error in the measurement of systolic blood pressure if disposable, built-in diaphragm, transducer domes or long extension tubes between the patient and pressure transducer are used. Sinusoidal or arterial pressure patterns were generated with specially designed equipment. With a long extension tube or trapped air bubbles, the resonant frequency of the catheter system was reduced so that the arterial pulse was amplified as it acted on the transducer and, thus, gave an erroneously high systolic pressure measurement. The authors found this error to be as much as 20 mm Hg. Trapped air bubbles, not stopcocks or connections, per se, lead to poor fidelity. The utility of a continuous catheter flush system (Sorenson, Intraflow) to estimate the resonant frequency and degree of damping of a catheter-transducer system is described, as are possibly erroneous conclusions. Given a rough estimate of the resonant frequency of a catheter-transducer system and the magnitude of overshoot in response to a pulse, the authors present a table to predict the magnitude of probable error. These studies confirm the variability and unreliability of static calibration that may occur using some safety diaphragm domes and show that the system frequency response is decreased if air bubbles are trapped between the diaphragms. The authors conclude that regular procedures should be established to evaluate the accuracy of the pressure measuring systems in use, the transducer should be placed as close to the patient as possible, the air bubbles should be assiduously eliminated from the system.

  6. Title: variations and sensitivities of some blood pressure monitors ...

    African Journals Online (AJOL)

    Blood pressure is the pressure exerted by circulating blood upon the walls of blood vessels. Accuracy in blood pressure meters is of essence to health, especially in blood pressure monitoring and treatment. The aim of this research was to compare the readings and the sensitivities of some blood pressure monitors in use ...

  7. Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya

    2018-01-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.

  8. High blood pressure - adults

    Science.gov (United States)

    ... pressure is found. This is called essential hypertension. High blood pressure that is caused by another medical condition or medicine you are taking is called secondary hypertension. Secondary hypertension may be due to: Chronic ...

  9. Relationship of central and peripheral blood pressure to left ventricular mass in hypertensive patients.

    Science.gov (United States)

    Pérez-Lahiguera, Francisco J; Rodilla, Enrique; Costa, Jose A; Gonzalez, Carmen; Martín, Joaquin; Pascual, Jose M

    2012-12-01

    The purpose of the present study was to assess the relationship of central and peripheral blood pressure to left ventricular mass. Cross-sectional study that included 392 never treated hypertensive individuals. Measurement of office, 24-h ambulatory, and central blood pressure (obtained using applanation tonometry) and determination of left ventricular mass by echocardiography were performed in all patients. In a multiple regression analysis, with adjustment for age, gender and metabolic syndrome, 24-h blood pressure was more closely related to ventricular mass than the respective office and central blood pressures. Systolic blood pressures always exhibited a higher correlation than diastolic blood pressures in all 3 determinations. The correlation between left ventricular mass index and 24-h systolic blood pressure was higher than that of office (P<.002) or central systolic blood pressures (P<.002). Changes in 24-h systolic blood pressure caused the greatest variations in left ventricular mass index (P<.001). In our population of untreated middle-aged hypertensive patients, left ventricular mass index is more closely related to 24-h ambulatory blood pressure than to office or central blood pressure. Central blood pressure does not enable us to better identify patients with left ventricular hypertrophy. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  10. Effect of Ramadan Fasting on Blood Pressure and Lipid Profiles

    Directory of Open Access Journals (Sweden)

    Maryam sadat Amirkalali sijavandi

    2015-09-01

    Full Text Available Introduction: Ramadan is a holy month for Muslims during which avoid from eating, drinking and sexual intercourse for about 13-17 hours. The aim of this study was surveying the effects of Islamic fasting in Ramadan on lipid profile and blood pressure.Materials and Methods: we designed this study in two phases, a week before and a week after Ramadan month. Eighty nine healthy subjects with 20-50 years old were participated in this study. Blood sampling for lipid profile measurement was done in the morning and blood pressure was measured in the afternoon with digital sphygmomanometer. Statistical analysis was performed with SPSS version 16.0 software.Results: In a week after Ramadan, body weight and body mass index (BMI decreased in both sexes, comparing with the week before Ramadan measurements (p

  11. [Unhealthy behavior associated with the development of high blood pressure in adolescents].

    Science.gov (United States)

    Sánchez-Zamorano, Luisa María; Burguete-García, Ana Isabel; Flores-Sánchez, Guillermo; Salmerón-Castro, Jorge; Lazcano-Ponce, Eduardo C; Diaz-Benitez, Cinthya E

    2017-04-03

    This article aims to evaluate the association between unhealthy behavior pattern and prevalence and incidence of high blood pressure in adolescents. Based on data from a cohort study with a baseline population of 2,813 adolescents enrolled in a public school system, the study measured the baseline prevalence and incidence of high blood pressure as a function of smoking, alcohol and illegal drug use, and physical activity. These variables were used to build a model called "unhealthy behavior pattern", and its relationship was evaluated in relation to high blood pressure in adolescents, using multiple logistic regression models. Prevalence of high blood pressure was 8.67%. Accumulated incidence of high blood pressure was 7.58%. In the multivariate analysis of high blood pressure adjusted by degree of adiposity, there was an association with the unhealthy behavior pattern in males (OR = 3.13; 95%CI: 1.67-5.84). The association between incidence of high blood pressure and unhealthy behavior pattern was observed in females (OR = 2.34; 95%CI: 1.11-4.95). In conclusion, high blood pressure is present in the adolescent population, associated with unhealthy behaviors like smoking, alcohol and illegal drug use, and physical inactivity, independently of the degree of adiposity.

  12. Home Blood Pressure Monitoring as an Alternative to Confirm Diagnoses of Hypertension in Adolescents with Elevated Office Blood Pressure from a Brazilian State Capital

    Science.gov (United States)

    Póvoa, Thaís Inacio Rolim; Jardim, Thiago Veiga; Carneiro, Carolina de Souza; Ferreira, Vanessa Roriz; Mendonça, Karla Lorena; de Morais, Polyana Resende Silva; Nascente, Flávia Miquetichuc Nogueira; de Souza, Weimar Kunz Sebba Barroso; Sousa, Ana Luiza Lima; Jardim, Paulo César Brandão Veiga

    2017-01-01

    Background Regional differences of using home blood pressure monitoring (HBPM) as an alternative to ambulatory blood pressure monitoring (ABPM) in hypertensive adolescents are unknown. Objectives Define if HBPM is an option to confirm diagnoses of hypertension in adolescents from a Brazilian capital with elevated office blood pressure (BP). Methods Adolescents (12-18years) from public and private schools with BP > 90th percentile were studied to compare and evaluate the agreement among office BP measurements, HBPM and ambulatory BP monitoring. Office BP measurements, HBPM and ABPM were performed according to guidelines recommendations. Semi-automatic devices were used for BP measurements. Values of p ABPM values (120.3 ± 12.6 mmHg x 121.5 ± 9.8 mmHg - p = 0.111 and 69.4 ± 7.7 mmHg x 70.2 ± 6.6 mmHg - p = 0.139) and lower than the office measurement values (127.3 ± 13.8 mmHg over 74.4 ± 9.5 mmHg - p ABPM. Conclusions HBPM is an option to confirm diagnoses of hypertension in adolescents from a Brazilian state capital with elevated office BP and can be used as an alternative to ABPM. PMID:28793045

  13. Ambulatory versus home versus clinic blood pressure: the association with subclinical cerebrovascular diseases: the Ohasama Study.

    Science.gov (United States)

    Hara, Azusa; Tanaka, Kazushi; Ohkubo, Takayoshi; Kondo, Takeo; Kikuya, Masahiro; Metoki, Hirohito; Hashimoto, Takanao; Satoh, Michihiro; Inoue, Ryusuke; Asayama, Kei; Obara, Taku; Hirose, Takuo; Izumi, Shin-Ichi; Satoh, Hiroshi; Imai, Yutaka

    2012-01-01

    The usefulness of ambulatory, home, and casual/clinic blood pressure measurements to predict subclinical cerebrovascular diseases (silent cerebrovascular lesions and carotid atherosclerosis) was compared in a general population. Data on ambulatory, home, and casual/clinic blood pressures and brain MRI to detect silent cerebrovascular lesions were obtained in 1007 subjects aged ≥55 years in a general population of Ohasama, Japan. Of the 1007 subjects, 583 underwent evaluation of the extent of carotid atherosclerosis. Twenty-four-hour, daytime, and nighttime ambulatory and home blood pressure levels were closely associated with the risk of silent cerebrovascular lesions and carotid atherosclerosis (all Ppressure values were simultaneously included in the same regression model, each of the ambulatory blood pressure values remained a significant predictor of silent cerebrovascular lesions, whereas home blood pressure lost its predictive value. Of the ambulatory blood pressure values, nighttime blood pressure was the strongest predictor of silent cerebrovascular lesions. The home blood pressure value was more closely associated with the risk of carotid atherosclerosis than any of the ambulatory blood pressure values when home and one of the ambulatory blood pressure values were simultaneously included in the same regression model. The casual/clinic blood pressure value had no significant association with the risk of subclinical cerebrovascular diseases. Although the clinical indications for ambulatory blood pressure monitoring and home blood pressure measurements may overlap, the clinical significance of each method for predicting target organ damage may differ for different target organs.

  14. Reactive rise in blood pressure upon cuff inflation: cuff inflation at the arm causes a greater rise in pressure than at the wrist in hypertensive patients.

    Science.gov (United States)

    Charmoy, Alexia; Würzner, Grégoire; Ruffieux, Christiane; Hasler, Christopher; Cachat, François; Waeber, Bernard; Burnier, Michel

    2007-10-01

    Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (Pblood pressure response to cuff inflation was independent of baseline blood pressure. The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of blood pressure.

  15. Diurnal changes of blood pressure values (24 h blood pressures in women with polycystic ovary syndrome

    Directory of Open Access Journals (Sweden)

    Barbara Grzechocińska

    2011-06-01

    Full Text Available Background: More attention is being paid lately to polycystic ovary syndrome (PCOS not only in the aspect of fertility but also according to long-term metabolic and cardiovascular abnormalities. Observations of women with PCOS show that the occurrence of blood hypertension is more frequent after the menopause. There are few articles concerning the predictable symptoms of blood hypertension. It seems that twenty-four hour blood pressure monitoring and assessment of changes of diurnal rhythm could be useful in this group of patients.Aim of the study: The purpose of this study was to assess diurnal changes of blood pressure in women with polycystic ovary syndrome.Material and methods: 26 women with PCOS diagnosed according to Rotterdam consensus criteria and Androgen Excess Society (AES criteria were included in our study. The mean age of the examined women was 29.5 years and the mean BMI (body mass index was 24.7 kg/m2. The control group consisted of 12 age-matched women, without PCOS. Twenty-four hour Holter monitoring of ambulatory blood pressure was performed during normal daily activity in all patients. Halberg’s cosinor method was used to analyse daily biorhythm.Results: Results show the diurnal changes of systolic blood pressure in the preclinical phase in 30% and diastolic in 15% of PCOS women. In this group no physiological decrease of blood pressure at night time was observed.

  16. Alanine increases blood pressure during hypotension

    Science.gov (United States)

    Conlay, L. A.; Maher, T. J.; Wurtman, R. J.

    1990-01-01

    The effect of L-alanine administration on blood pressure (BP) during haemorrhagic shock was investigated using anesthetized rats whose left carotid arteries were cannulated for BP measurement, blood removal, and drug administration. It was found that L-alanine, in doses of 10, 25, 50, 100, and 200 mg/kg, increased the systolic BP of hypotensive rats by 38 to 80 percent (while 100 mg/kg pyruvate increased BP by only 9.4 mmhg, not significantly different from saline). The results suggest that L-alanine might influence cardiovascular function.

  17. Estimation of blood pressure from non-invasive data.

    Science.gov (United States)

    Shukla, Satya Narayan

    2017-07-01

    Blood pressure (BP) is one of the most important physiological parameter that can provide crucial information for health care. The widely used cuff based technology is not very convenient or comfortable as it occludes the blood flow in the arteries during the time of measurement. In past, Phonocardiogram (PCG), Electrocardiogram (ECG) and Photoplethysmogram (PPG) signals have been used to predict the BP values. In this paper, we propose to estimate the blood pressure from PPG using Multi Task Gaussian Processes (MTGPs) and compare with Artificial Neural networks (ANNs). Both MTGPs and ANNs are evaluated on the clinical data obtained from MIMIC Database. The performance of the proposed method is found to be comparable or better than the existing methods of computing BP from non-invasive data.

  18. Validation of the AVITA BPM15S wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Zhang, Lu; Li, Yan; Wang, Ji-Guang

    2014-06-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM15S for home blood pressure monitoring according to the International Protocol revision 2010 of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 Chinese adults (15 women, mean age 51 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM15S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM15S device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg were 85/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 82/99, 96/99, and 98/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Thirty-two and 28 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥ 24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The AVITA wrist blood pressure monitor BPM15S fulfilled the requirements of the International Protocol revision 2010 and hence can be recommended for home use in an adult population.

  19. 21 CFR 870.1120 - Blood pressure cuff.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...

  20. Effect of cocoa on blood pressure.

    Science.gov (United States)

    Ried, Karin; Fakler, Peter; Stocks, Nigel P

    2017-04-25

    High blood pressure is an important risk factor for cardiovascular disease, contributing to about 50% of cardiovascular events worldwide and 37% of cardiovascular-related deaths in Western populations. Epidemiological studies suggest that cocoa-rich products reduce the risk of cardiovascular disease. Flavanols found in cocoa have been shown to increase the formation of endothelial nitric oxide which promotes vasodilation and therefore blood pressure reduction. Here we update previous meta-analyses on the effect of cocoa on blood pressure. To assess the effects on blood pressure of chocolate or cocoa products versus low-flavanol products or placebo in adults with or without hypertension when consumed for two weeks or longer. This is an updated version of the review initially published in 2012. In this updated version, we searched the following electronic databases from inception to November 2016: Cochrane Hypertension Group Specialised Register, CENTRAL, MEDLINE and Embase. We also searched international trial registries, and the reference lists of review articles and included trials. Randomised controlled trials (RCTs) investigating the effects of chocolate or cocoa products on systolic and diastolic blood pressure in adults for a minimum of two weeks duration. Two review authors independently extracted data and assessed the risks of bias in each trial. We conducted random-effects meta-analyses on the included studies using Review Manager 5. We explored heterogeneity with subgroup analyses by baseline blood pressure, flavanol content of control group, blinding, age and duration. Sensitivity analyses explored the influence of unusual study design. Thirty-five trials (including 40 treatment comparisons) met the inclusion criteria. Of these, we added 17 trials (20 treatment comparisons) to the 18 trials (20 treatment comparisons) in the previous version of this updated review.Trials provided participants with 30 to 1218 mg of flavanols (mean = 670 mg) in 1.4 to 105

  1. Cocoa, blood pressure, and cardiovascular health.

    Science.gov (United States)

    Ferri, Claudio; Desideri, Giovambattista; Ferri, Livia; Proietti, Ilenia; Di Agostino, Stefania; Martella, Letizia; Mai, Francesca; Di Giosia, Paolo; Grassi, Davide

    2015-11-18

    High blood pressure is an important risk factor for cardiovascular disease and cardiovascular events worldwide. Clinical and epidemiological studies suggest that cocoa-rich products reduce the risk of cardiovascular disease. According to this, cocoa has a high content in polyphenols, especially flavanols. Flavanols have been described to exert favorable effects on endothelium-derived vasodilation via the stimulation of nitric oxide-synthase, the increased availability of l-arginine, and the decreased degradation of NO. Cocoa may also have a beneficial effect by protecting against oxidative stress alterations and via decreased platelet aggregation, decreased lipid oxidation, and insulin resistance. These effects are associated with a decrease of blood pressure and a favorable trend toward a reduction in cardiovascular events and strokes. Previous meta-analyses have shown that cocoa-rich foods may reduce blood pressure. Long-term trials investigating the effect of cocoa products are needed to determine whether or not blood pressure is reduced on a chronic basis by daily ingestion of cocoa. Furthermore, long-term trials investigating the effect of cocoa on clinical outcomes are also needed to assess whether cocoa has an effect on cardiovascular events. A 3 mmHg systolic blood pressure reduction has been estimated to decrease the risk of cardiovascular and all-cause mortality. This paper summarizes new findings concerning cocoa effects on blood pressure and cardiovascular health, focusing on putative mechanisms of action and "nutraceutical " viewpoints.

  2. A Pilot Study: Comparison of Arm Versus Ankle Noninvasive Blood Pressure Measurement at 2 Different Levels of Backrest Elevation.

    Science.gov (United States)

    Henley, Nicole; Quatrara, Beth D; Conaway, Mark

    2015-01-01

    Standard practice for obtaining noninvasive blood pressure includes arm blood pressure (BP) cuff placement at the level of the heart; however, some critical care patients cannot have BPs taken in their arm because of various conditions, and ankle BPs are frequently used as substitutes. The aim of this study was to determine if there was a significant variation between upper arm and ankle BP measurements at different backrest elevations with consideration of peripheral edema factors. After institutional review board approval was obtained, a pilot study was implemented to evaluate noninvasive BP measurements of the arm and ankle with backrest elevation at 0° and 30° in a population of medical intensive care unit patients. Participants served as their own controls and were randomly assigned to left- versus right-side BP readings. Data were also collected on presence of arm versus ankle edema. A total of 30 participants enrolled in the study and provided 120 BP measurements. Blood pressure readings were analyzed in terms of diastolic and systolic findings as well as backrest elevations and edema presence. Thirteen participants presented with either arm or ankle edema. There was a statistical difference between the systolic arm and ankle BP measurements in the 0° (P = .008) and 30° (P arm and ankle diastolic BP is greater for participants without ankle edema (P = .038, r = 0.54) than for participants with ankle edema (P = .650, r = 0.14), but it is not statistically significant (P = .47). Even though ankle BPs are often substituted for arm BPs when the arm is unable to be used, ankle BPs and arm BPs are not interchangeable. Adjustments in backrest elevation and considerations of edema do not normalize the differences. Blood pressures obtained from the ankle are significantly greater than those obtained from the arm. This information needs to be considered when arms are not available and legs are used as surrogates for the upper arm.

  3. Fall in blood pressure during radiation therapy

    International Nuclear Information System (INIS)

    Larsson, L.E.; Lindahl, J.; Unsgaard, B.

    1976-01-01

    Blood pressure and heart rate at rest in the supine and standing positions were followed before, during and after irradiation for malignant tumours in 114 patients. A statistically significant gradual reduction in blood pressure during the treatment period was established. This was more marked in older patients and in patients with higher initial blood pressure but was not related to the region irradiated or the type of tumour treated. Particularly if the patient experiences vertigo and nausea on change of position, it seems advisable to check the blood pressure during treatment. (author)

  4. Substantial effect of acute hydration on blood pressure in patients with autonomic failure

    DEFF Research Database (Denmark)

    Mehlsen, J; Boesen, F

    1987-01-01

    fraction were measured in the supine position. Measurements were repeated after rapid infusion of 11 of isotonic saline. Acute hydration resulted in increased supine mean blood pressure levels (P less than 0.01) despite normal plasma volumes in all patients. The postural reductions in mean blood pressure......The effect of acute hydration on arterial blood pressure levels was investigated in ten patients with severe postural hypotension due to autonomic failure. Blood pressure and heart rate were determined in the supine and 60-degree head-up tilted position. Plasma volume and left ventricular ejection...... were reduced from 40 mmHg before to 20 mmHg after saline (median values, P less than 0.01). The results indicate that normal plasma volumes do not ensure optimal circulatory status in patients with autonomic failure. Acute hydration with isotonic saline may be used for immediate corrections of blood...

  5. Closure of digital arteries in high vascular tone states as demonstrated by measurement of systolic blood pressure in the fingers

    DEFF Research Database (Denmark)

    Krähenbühl, B; Nielsen, S L; Lassen, N A

    1977-01-01

    by direct cooling or intra-arterial noradrenaline infusion caused a marked drop in FSP in the exposed fingers, but not in the non-exposed fingers of the same hand. The fact that the non-exposed fingers retained the normal (arm systolic) pressure level is taken to indicate that palmar arch blood pressure......Finger systolic blood pressure (FSP) was measured indirectly in normal subjects and patients with primary Raynaud phenomenon by applying a thin-walled plastic cuff around the finger and a strain gauge more distally to detect volume changes. Inducing a high vascular tone in one or more fingers...... also remained normal. In the high vascular tone state, a large transmural pressure difference must apparently be established before the digital arteries are forced open. The lowered opening pressure constitutes a manifestation of the closure phenomenon of the digital arteries described in patients...

  6. Standing orthostatic blood pressure measurements cannot be replaced by sitting measurements.

    Science.gov (United States)

    Breeuwsma, Anna C; Hartog, Laura C; Kamper, Adriaan M; Groenier, Klaas H; Bilo, Henk Jg; Kleefstra, Nanne; Van Hateren, Kornelis Jj

    2017-08-01

    As many elderly patients are not able to stand for several minutes, sitting orthostatic blood pressure (BP) measurements are sometimes used as an alternative. We aimed to investigate the difference in BP response and orthostatic hypotension (OH) prevalence between the standard postural change to the sitting and the standing position in a cross-sectional observational study. BP was measured with a continuous BP measurement device during two postural changes, from supine to the sitting and from supine to the standing position. Linear mixed models were used to investigate the differences in changes (Δ) of systolic BP (SBP) and diastolic BP (DBP) between the two postural changes. The prevalence and the positive and negative proportions of agreement of OH were calculated of the two postural changes. One hundred and four patients with a mean age of 69 years were included. ΔSBP was significantly larger in the standing position compared with the sitting between 0 and 44 s. ΔDBP was significantly larger in the sitting position compared with the standing 75-224 s after postural change. The prevalence of OH was 66.3% (95% confidence interval (CI) 57.2, 75.4) in the standing position and 67.3% (95% CI 58.3, 76.3) in the sitting position. The positive proportion of agreement was 74.8% and the negative proportion of agreement was 49.3%. A clear difference was seen in BP response between the two postural changes. Although no significant difference in prevalence of OH was observed, the positive and negative proportion of agreement of the prevalence of OH were poor to moderate, which indicates a different outcome between both postural changes.

  7. Automated measurement of office, home and ambulatory blood pressure in atrial fibrillation.

    Science.gov (United States)

    Kollias, Anastasios; Stergiou, George S

    2014-01-01

    1. Hypertension and atrial fibrillation (AF) often coexist and are strong risk factors for stroke. Current guidelines for blood pressure (BP) measurement in AF recommend repeated measurements using the auscultatory method, whereas the accuracy of the automated devices is regarded as questionable. This review presents the current evidence on the feasibility and accuracy of automated BP measurement in the presence of AF and the potential for automated detection of undiagnosed AF during such measurements. 2. Studies evaluating the use of automated BP monitors in AF are limited and have significant heterogeneity in methodology and protocols. Overall, the oscillometric method is feasible for static (office or home) and ambulatory use and appears to be more accurate for systolic than diastolic BP measurement. 3. Given that systolic hypertension is particularly common and important in the elderly, the automated BP measurement method may be acceptable for self-home and ambulatory monitoring, but not for professional office or clinic measurement. 4. An embedded algorithm for the detection of asymptomatic AF during routine automated BP measurement with high diagnostic accuracy has been developed and appears to be a useful screening tool for elderly hypertensives. © 2013 Wiley Publishing Asia Pty Ltd.

  8. Blood Pressure and Intracranial Aneurysms in Autosomal Dominant Polycystic Kidney Disease

    Directory of Open Access Journals (Sweden)

    Mariusz Niemczyk

    2014-12-01

    Full Text Available Background/Aims: Autosomal dominant polycystic kidney disease (ADPKD is correlated with an increased frequency of both intracranial aneurysms (ICANs, and arterial hypertension (AH. The aim of our study was to search for the association between blood pressure (BP and ICANs in ADPKD patients. Methods: Sixty-eight adult, pre-dialysis phase ADPKD patients underwent both screening for ICANs with magnetic resonance angiography of the brain, and ambulatory blood pressure monitoring (ABPM. Results: ICANs were diagnosed in 10 patients (ICAN(+ group, while in 58 were not (ICAN(- group. The nighttime maximum diastolic blood pressure (DBP, maximum increase in DBP from measurement to measurement (positive delta of DBP at night, and the standard deviation of the daytime mean arterial pressure were significantly higher in ICAN(+ compared to ICAN(- patients. Additionally, in a subgroup of patients after 45 years-of-age, ICAN(+ patients had significantly higher maximum 24-hour and daytime systolic blood pressure, maximum 24-hour, daytime, nighttime DBP, maximum daytime and nighttime positive delta of DBP compared to ICAN(- cases. Conclusions: Development of ICANs in hypertensive ADPKD patients is accompanied with higher values of some BP parameters measured by ABPM. Hypertensive ADPKD patients with substantial fluctuations in BP assessed by ABPM, especially those after 45 years-of-age, should become candidates for screening for ICANs.

  9. Limitations of the usual blood-pressure hypothesis and importance of variability, instability, and episodic hypertension.

    Science.gov (United States)

    Rothwell, Peter M

    2010-03-13

    Although hypertension is the most prevalent treatable vascular risk factor, how it causes end-organ damage and vascular events is poorly understood. Yet, a widespread belief exists that underlying usual blood pressure can alone account for all blood-pressure-related risk of vascular events and for the benefits of antihypertensive drugs, and this notion has come to underpin all major clinical guidelines on diagnosis and treatment of hypertension. Other potentially informative measures, such as variability in clinic blood pressure or maximum blood pressure reached, have been neglected, and effects of antihypertensive drugs on such measures are largely unknown. Clinical guidelines recommend that episodic hypertension is not treated, and the potential risks of residual variability in blood pressure in treated hypertensive patients have been ignored. This Review discusses shortcomings of the usual blood-pressure hypothesis, provides background to accompanying reports on the importance of blood-pressure variability in prediction of risk of vascular events and in accounting for benefits of antihypertensive drugs, and draws attention to clinical implications and directions for future research. Copyright 2010 Elsevier Ltd. All rights reserved.

  10. Validation of the OMRON M7 (HEM-780-E) blood pressure measuring device in a population requiring large cuff use according to the International Protocol of the European Society of Hypertension.

    Science.gov (United States)

    El Feghali, Ramzi N; Topouchian, Jirar A; Pannier, Bruno M; El Assaad, Hiba A; Asmar, Roland G

    2007-06-01

    A high percentage of hypertensive patients present an arm circumference of over 32 cm; the use of a large cuff is therefore recommended. Validation studies are usually performed in the general population using a standard-size cuff. The aim of this study was to assess the accuracy of the Omron M7 device in a population with an arm circumference ranging from 32 to 42 cm. A validation study was performed according to the International Protocol of the European Society of Hypertension. This protocol is divided into two phases: the first phase is performed on 15 selected participants (45 pairs of blood-pressure measurements); if the device passes this phase, 18 supplementary participants are included (54 pairs of blood-pressure measurements), making a total number of 33 participants (99 pairs of blood-pressure measurements), on whom the analysis is performed. For each participant, four blood-pressure measurements were performed simultaneously by two trained observers, using mercury sphygmomanometers fitted with a Y tube; the measurements alternated with three by the test device. The difference between the blood-pressure value given by the device and that obtained by the two observers (mean of the two observations) was calculated for each measure. The 99 pairs of blood-pressure differences were classified into three categories (Society of Hypertension protocol. The Omron M7 device passed the first and the second phases of the validation process. The average differences between the two observers were 1.5+/-3.2 and -0.5+/-2.2 mmHg for systolic blood pressure and diastolic blood pressure, and those between the device and the mercury sphygmomanometer were -1.6+/-6.7 for systolic blood pressure and -0.12+/-4.0 mmHg for diastolic blood pressure Readings that differ by less than 5, 10 and 15 mmHg for systolic blood-pressure and diastolic blood-pressure values fulfill the recommendation criteria of the European Society of Hypertension protocol. The Omron M7 (HEM-780-E) device

  11. Long-term facial artery catheter implantation for serial arterial blood sampling and invasive arterial blood pressure measurement in horses.

    Science.gov (United States)

    Dias, Deborah Penteado Martins; Teixeira, Luisa Gouvêa; Canola, Paulo Aléscio; Albernaz, Raquel Mincarelli; Marques, José Antônio; Neto, José Corrêa de Lacerda

    2012-06-01

    The purpose of this investigation was to evaluate surgical catheter implantation in the facial artery of horses and the long-term maintenance of such arteries using heparin and ascorbic acid as filling solution. Nine horses were implanted with a polyurethane catheter. The catheters were flushed with a heparin/ascorbic acid solution every 8h and remained patent for 25 days. Arterial blood samples were collected twice a day, and one exercise test that included serial blood samples and arterial pressure recordings was performed on a treadmill. Polyurethane catheters surgically implanted in the facial artery can be kept patent by filling with a heparin/ascorbic acid solution and provide convenient invasive arterial access in horses which is suitable for use for serial blood sampling and blood pressure recordings, even during exercise on treadmill. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Validation of the YuWell YE690A upper-arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Chen, Qi; Lei, Lei; Li, Yan; Wang, Ji-Guang

    2017-10-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor YuWell YE690A for blood pressure measurement according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were measured sequentially in 33 adult Chinese (12 women, 44.2 years of mean age) using a mercury sphygmomanometer (two observers) and the YE690A device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The YuWell YE690A device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 79/99, 96/99, and 97/99, respectively, for systolic blood pressure and 72/99, 95/99, and 98/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Thirty-one and 25 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥24). No participant for systolic and two participants for diastolic blood pressure had all the three device-observer comparisons greater than 5 mmHg. The YuWell blood pressure monitor YE690A has passed the requirements of the International Protocol revision 2010 and hence can be recommended for blood pressure measurement in adults.

  13. Why use Finapres or Portapres rather than intra-arterial or intermittent non-invasive techniques of blood pressure measurement?

    NARCIS (Netherlands)

    Langewouters, G. J.; Settels, J. J.; Roelandt, R.; Wesseling, K. H.

    1998-01-01

    In the clinic, blood pressure is measured almost exclusively using non-invasive intermittent techniques, of which the auscultatory (Riva-Rocci/Korotkoff, RRK) and the computerized oscillometric method are most often used. However, both methods only provide a momentary value. In addition, the

  14. What Is High Blood Pressure Medicine?

    Science.gov (United States)

    ... a medicine calendar. • Set a reminder on your smartphone. What types of medicine may be prescribed? One ... High Blood Pressure Medicine? What are their side effects? For many people, high blood pressure medicine can ...

  15. Blood pressure measurement in epidemiological investigations in teenagers

    International Nuclear Information System (INIS)

    Coppieters, Yves; Parent, Florence; Berghmans, Luc; Godin, Isabelle; Leveque, Alain

    2001-01-01

    Background: The use of sphygmomanometers may lead to problems in investigations on health of young people. The purpose of this paper is to present the validation of the blood pressure (BP) collected during the survey 'Youth Heart Health' in Hainaut by using second sample of young people in Hainaut for which BP was measured by a manual taking of tension and by an electronic device. Methods: Validation was done with a control sample of 343 young with five successive BP measures: twice with the mercury sphygmomanometer and three with DXL. We compared the manual and the electronic measures in order to study the correlation between the two methods. The control sample was used in order to compare the BP measurements with the results of the survey on the health of young people in Hainaut. Results: The differences between manual systolic BP and Dinamap measures are significant (differences in averages 3.6 mmHg; d.s. 7.8; 95% CI: 2.8-4.4 mmHg; p < 0.001) and the regression coefficient is -0.015. Diastolic BP is significantly higher with the manual method than with Dinamap (differences in means: 8.2 mmHg; d.s. 7.0; 95% CI: 7.4-8.9 mmHg; p < 0.001) and the coefficient of regression is 0.096. We observe a difference in BP between the general survey and the control group (10.3 mmHg for systolic manual control and of 10.9 mmHg for systolic electronic control; 3.3 mmHg for diastolic manual control and of 11.5 mmHg for diastolic electronic control). Conclusions: The values of BP of the 'Youth Heart Health' are significantly higher. These observations indicate the difficulties in the choice of the tool for measurements of BP in epidemiological investigations in the teenagers. In order to decrease skews of observations in the measurement of BP, it is recommended to use a valid electronic instrument. Dinamap XL is an instrument of choice in such studies of young people. Environmental and organisational factors may also explain the observed difference, which means that survey

  16. Blood Pressure Quiz | NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... this page please turn Javascript on. Feature: High Blood Pressure Blood Pressure Quiz Past Issues / Fall 2011 Table of Contents Blood pressure changes throughout the day. It… is highest while ...

  17. Continuous blood pressure recordings simultaneously with functional brain imaging: studies of the glymphatic system

    Science.gov (United States)

    Zienkiewicz, Aleksandra; Huotari, Niko; Raitamaa, Lauri; Raatikainen, Ville; Ferdinando, Hany; Vihriälä, Erkki; Korhonen, Vesa; Myllylä, Teemu; Kiviniemi, Vesa

    2017-03-01

    The lymph system is responsible for cleaning the tissues of metabolic waste products, soluble proteins and other harmful fluids etc. Lymph flow in the body is driven by body movements and muscle contractions. Moreover, it is indirectly dependent on the cardiovascular system, where the heart beat and blood pressure maintain force of pressure in lymphatic channels. Over the last few years, studies revealed that the brain contains the so-called glymphatic system, which is the counterpart of the systemic lymphatic system in the brain. Similarly, the flow in the glymphatic system is assumed to be mostly driven by physiological pulsations such as cardiovascular pulses. Thus, continuous measurement of blood pressure and heart function simultaneously with functional brain imaging is of great interest, particularly in studies of the glymphatic system. We present our MRI compatible optics based sensing system for continuous blood pressure measurement and show our current results on the effects of blood pressure variations on cerebral brain dynamics, with a focus on the glymphatic system. Blood pressure was measured simultaneously with near-infrared spectroscopy (NIRS) combined with an ultrafast functional brain imaging (fMRI) sequence magnetic resonance encephalography (MREG, 3D brain 10 Hz sampling rate).

  18. Influence of lifestyle, coping, and job stress on blood pressure in men and women.

    Science.gov (United States)

    Lindquist, T L; Beilin, L J; Knuiman, M W

    1997-01-01

    We designed this study to clarify the role of work stress on long-term blood pressure control and in particular to investigate whether perceived work stress directly affected resting blood pressure levels or whether there were indirect effects mediated by coping mechanisms and lifestyle. Men (n = 337) and women (n = 317) working in a government tax office completed questionnaires for assessment of work-related stress, coping strategies, and lifestyle. Seven resting blood pressure measurements were recorded serially on each of two occasions a week apart. Men had higher blood pressures (119.6/68.6 versus 110.9/65.6 mm Hg) than women; they used more "maladaptive" coping strategies, drank more alcohol, and ate less healthily but exercised more than women. There were no direct associations between measures of work stress and blood pressure. In univariate and regression analyses, both body mass index and lifestyle factors in the form of alcohol consumption, exercise, and diet were related to blood pressure in men and women. Various "adaptive" or "maladaptive" coping mechanisms were identified and independently related to both job stress and blood pressure levels. Women were more likely to use "healthier" or adaptive coping mechanisms than men. Thus, work stress per se had no direct effect on blood pressure, but the ways that individuals reported coping with stress were significantly related to blood pressure, with blood pressure elevation effects appearing to be mediated largely by dietary and drinking habits and physical inactivity. The results point to the need to target individual coping strategies and lifestyle as much as the working environment in workplace cardiovascular health promotion programs.

  19. Benzodiazepine Consumption Is Associated With Lower Blood Pressure in Ambulatory Blood Pressure Monitoring (ABPM): Retrospective Analysis of 4938 ABPMs.

    Science.gov (United States)

    Mendelson, Nitsan; Gontmacher, Bella; Vodonos, Allina; Novack, Victor; Abu-AjAj, Muhammad; Wolak, Arik; Shalev, Haddar; Wolak, Talya

    2018-03-10

    The effect of chronic benzodiazepine use on blood pressure has not been documented. We aimed to evaluate whether regular benzodiazepine use can be associated to the results of ambulatory blood pressure monitoring (ABPM). A retrospective analysis of the ABPM database between 2009 and 2015 was performed. The study groups were divided according to benzodiazepine treatment at least 3 months before ABPM. Generalized estimating equation (GEE) model analysis was conducted to estimate the association between benzodiazepine treatment and ABPM test measurements. Multivariable COX regression survival analysis model for mortality and cardiovascular (CV) events was performed. A total of 4,938 ABPM studies were included in final analysis, 670 ABPMs of benzodiazepine-treated patients, and 4,268 of untreated patients. The benzodiazepine-treated group was significantly older, with a predominance of female patients, comprised more diabetic patients and consumed more antihypertensive medications. Adjustment for age, gender, diabetes mellitus, and number of antihypertensive medications, showed an association between benzodiazepine treatment and significantly lower ABPM measurements. When the analysis was split into those ≥60 years old and the other ABPM measurements only among ≥60 years old. Multivariable Cox regression survival analysis showed that regular benzodiazepine consumption was not associated with increased mortality or CV events (mean follow-up period of 42.4 ± 19.8 and 42.1 ± 20.0 months, respectively). Long-term use of benzodiazepines by ≥60 years old was independently associated with lower diastolic and systolic blood pressure in all parameters of ABPM, but not among younger patients.

  20. Ambulatory blood pressure monitoring in patients with hyperthyroidism before the introduction of therapy and on therapy

    Directory of Open Access Journals (Sweden)

    Stojanović Miloš

    2017-01-01

    Full Text Available The increased secretion of thyroid gland hormones affects the cardiovascular system by increasing heart rate and often by increasing systolic and diastolic blood pressure. We examined the influence of elevated thyroid hormone on blood pressure. Blood pressure monitoring was performed prior to the introduction of therapy in people with increased FT4 and on therapy when FT4 was in the normal range. We analyzed 32 people, of which 26 women had normal blood pressure values measured by blood pressure monitoring. Average age 45 and body mass index 27 kg/m2. Blood pressure was measured by monitoring blood pressure for 24 hours. On average, before the introduction of the therapy, it was 133/83 mmHg P 96 / min. The blood pressure on average on therapy with tireosuppressive was 128/82 mmHg P 74 / min. The Wilcoxon-Mann-Whitney paired test shows a significant P <0.05 higher systolic blood pressure and pulse rate during the day and night before the treatment, when FT4 was higher, than the time when medication was taking, when the FT4 was in the normal range. No significant difference was found for diastolic blood pressure before the introduction of therapy and during therapy with tireosuppressives. When values of FT4 are increased, monitoring of blood pressure shows significantly higher values of systolic blood pressure and pulse during day and night compared to systolic blood pressure and pulse values when FT4 is in the normal range.

  1. Pulmonary blood flow distribution measured by radionuclide computed tomography

    International Nuclear Information System (INIS)

    Maeda, H.; Itoh, H.; Ishii, Y.

    1982-01-01

    Distributions of pulmonary blood flow per unit lung volume were measured in sitting patients with a radionuclide computed tomography (RCT) by intravenously administered Tc-99m macroaggregates of human serum albumin (MAA). Four different types of distribution were distinguished, among which a group referred as type 2 had a three zonal blood flow distribution as previously reported (West and co-workers, 1964). The pulmonary arterial pressure (Pa) and the venous pressure (Pv) were determined in this group of distribution. These values showed satifactory agreements with the pulmonary artery pressure (Par) and the capillary wedged pressure (Pcw) measured by Swan-Ganz catheter in eighteen supine patients. Those good correlations enable to establish a noninvasive methodology for measurement of pulmonary vascular pressures

  2. Correlation of Noninvasive Blood Pressure and Invasive Intra-arterial Blood Pressure in Patients Treated with Vasoactive Medications in a Neurocritical Care Unit.

    Science.gov (United States)

    Saherwala, Ali A; Stutzman, Sonja E; Osman, Mohamed; Kalia, Junaid; Figueroa, Stephen A; Olson, DaiWai M; Aiyagari, Venkatesh

    2018-03-22

    The correlation between noninvasive (oscillometric) blood pressure (NBP) and intra-arterial blood pressure (IAP) in critically ill patients receiving vasoactive medications in a Neurocritical Care Unit has not been systematically studied. The purpose of this study is to examine the relationship between simultaneously measured NBP and IAP recordings in these patients. Prospective observational study of patients (N = 70) admitted to a neurocritical care unit receiving continuous vasopressor or antihypertensive infusions. Paired NBP/IAP observations along with covariate and demographic data were abstracted via chart audit. Analysis was performed using SAS v9.4. A total of 2177 paired NBP/IAP observations from 70 subjects (49% male, 63% white, mean age 59 years) receiving vasopressors (n = 21) or antihypertensive agents (n = 49) were collected. Paired t test analysis showed significant differences between NBP versus IAP readings: ([systolic blood pressure (SBP): mean = 136 vs. 140 mmHg; p blood pressure (DBP): mean = 70 vs. 68 mmHg, p blood pressure (MAP): mean = 86 vs. 90 mmHg, p blood pressures. Pearson correlation coefficients show strong positive correlations for paired MAP (r = 0.82), SBP (r = 0.84), and DBP (r = 0.73) recordings. An absolute NBP-IAP SBP difference of > 20 mmHg was seen in ~ 20% of observations of nicardipine, ~ 25% of observations of norepinephrine, and ~ 35% of observations of phenylephrine. For MAP, the corresponding numbers were ~ 10, 15, and 25% for nicardipine, norepinephrine, and phenylephrine, respectively. Despite overall strong positive correlations between paired NBP and IAP readings of MAP and SBP, clinically relevant differences in blood pressure are frequent. When treating with vasoactive infusions targeted to a specific BP goal, it is important to keep in mind that NBP and IAP values are not interchangeable.

  3. The Utility of Ambulatory Blood Pressure Monitoring for Diagnosing White Coat Hypertension in Older Adults.

    Science.gov (United States)

    Reynolds, Kristi; Bowling, C Barrett; Sim, John J; Sridharan, Lakshmi; Harrison, Teresa N; Shimbo, Daichi

    2015-11-01

    The beneficial effect of antihypertensive medication on reducing the risk of cardiovascular disease (CVD) events is supported by data from randomized controlled trials of older adults with hypertension. However, in clinical practice, overtreatment of hypertension in older adults may lead to side effects and an increased risk of falls. The diagnosis and treatment of hypertension is primarily based on blood pressure measurements obtained in the clinic setting. Ambulatory blood pressure monitoring (ABPM) complements clinic blood pressure by measuring blood pressure in the out-of-clinic setting. ABPM can be used to identify white coat hypertension, defined as elevated clinic blood pressure and non-elevated ambulatory blood pressure. White coat hypertension is common in older adults but does not appear to be associated with an increased risk of CVD events among this population. Herein, we review the current literature on ABPM in the diagnoses of white coat hypertension in older adults, including its potential role in preventing overtreatment.

  4. The Utility of Ambulatory Blood Pressure Monitoring for Diagnosing White Coat Hypertension in Older Adults

    Science.gov (United States)

    Reynolds, Kristi; Bowling, C. Barrett; Sim, John J.; Sridharan, Lakshmi; Harrison, Teresa N.; Shimbo, Daichi

    2015-01-01

    The beneficial effect of antihypertensive medication on reducing the risk of cardiovascular disease (CVD) events is supported by data from randomized controlled trials of older adults with hypertension. However, in clinical practice, overtreatment of hypertension in older adults may lead to side effects and an increased risk of falls. The diagnosis and treatment of hypertension is primarily based on blood pressure measurements obtained in the clinic setting. Ambulatory blood pressure monitoring (ABPM) complements clinic blood pressure by measuring blood pressure in the out-of-clinic setting. ABPM can be used to identify white coat hypertension, defined as elevated clinic blood pressure and non-elevated ambulatory blood pressure. White coat hypertension is common in older adults but does not appear to be associated with an increased risk of CVD events among this population. Herein, we review the current literature on ABPM in the diagnoses of white coat hypertension in older adults, including its potential role in preventing overtreatment. PMID:26400076

  5. Hypertension in diabetes as related to nephropathy. Early blood pressure changes

    DEFF Research Database (Denmark)

    Feldt-Rasmussen, B; Borch-Johnsen, K; Mathiesen, E R

    1985-01-01

    We measured the blood pressure under standardized conditions in three groups of patients with type I (insulin-dependent) diabetes: group 1, patients with Albustix-negative urine and normal urinary albumin excretion rate below 20 micrograms/min; group 2, patients with Albustix-negative urine and e...... that arterial hypertension is an early feature in the developing of diabetic nephropathy, with blood pressure rising before the presence of clinical proteinuria.......We measured the blood pressure under standardized conditions in three groups of patients with type I (insulin-dependent) diabetes: group 1, patients with Albustix-negative urine and normal urinary albumin excretion rate below 20 micrograms/min; group 2, patients with Albustix-negative urine...... and elevated urinary albumin excretion rate 20 to 200 micrograms/min; and group 3, patients with Albustix-positive urine at the time of diagnosis of diabetic nephropathy, that is, proteinuria greater than 0.5 g/24 hr on four consecutive visits with an interval of more than 1 month. We also studied blood...

  6. Different Relevance of Peripheral, Central or Nighttime Blood Pressure Measurements in the Prediction of Chronic Kidney Disease Progression in Patients with Mild or No-Proteinuria.

    Science.gov (United States)

    Kuczera, Piotr; Kwiecień, Katarzyna; Adamczak, Marcin; Bączkowska, Teresa; Gozdowska, Jolanta; Madziarska, Katarzyna; Augustyniak-Bartosik, Hanna; Klinger, Marian; Durlik, Magdalena; Ritz, Eberhard; Wiecek, Andrzej

    2018-05-10

    Arterial hypertension is one of the leading factors aggravating the course of chronic kidney disease (CKD). It seems that the novel parameters used in the assessment of the blood pressure (BP) load (i.e. central blood pressure, nighttime blood pressure) may be more precise in predicting the cardiovascular risk and the progression of CKD in comparison with the traditional peripheral blood pressure measurements in the office conditions. The aim of the study was to assess the impact of the central, or nighttime blood pressure on the progression of CKD in patients with mild or no-proteinuria (autosomal, dominant polycystic kidney disease or IgA nephropathy). In each of the enrolled 46 patients with CKD stage 3 or 4, serum creatinine concentration was assessed, eGFR (MDRD) was calculated, also central blood pressure and pulse wave velocity (PWV) was assessed and the 24-hour ambulatory blood pressure monitoring (ABPM) was conducted at the beginning of the study and then repeated after one-year observation period. During the observation period mean eGFR decreased from 44.1 (33.2-50.6) mL/min to 36.7 (29.7-46.3) mL/min. No significant differences were observed in the peripheral blood pressure or central blood pressure parameters. After one-year observation period the values of diastolic blood pressure dipping during the night significantly decreased from 16 (13-19) mmHg to 12 (10-15) mmHg; pblood pressure did not change significantly during a one-year observation period despite the significant decline of eGFR and seems not to participate in the CKD progression. 2. Reduced magnitude of the diastolic dipping, which reflects the increase of diastolic blood pressure load during the nighttime, may play an important role in the pathogenesis of deterioration of kidney function in these patients. © 2018 The Author(s). Published by S. Karger AG, Basel.

  7. Inter-arm blood pressure difference in type 2 diabetes: a barrier to effective management?

    Science.gov (United States)

    Clark, Christopher E; Greaves, Colin J; Evans, Philip H; Dickens, Andy; Campbell, John L

    2009-06-01

    Previous studies have identified a substantial prevalence of a blood pressure difference between arms in various populations, but not patients with type 2 diabetes. Recognition of such a difference would be important as a potential cause of underestimation of blood pressure. To measure prevalence of an inter-arm blood pressure difference in patients with type 2 diabetes, and to estimate how frequently blood pressure measurements could be erroneously underestimated if an inter-arm difference is unrecognised. Cross-sectional study. Five surgeries covered by three general practices, Devon, England. Patients with type 2 diabetes underwent bilateral simultaneous blood pressure measurements using a validated protocol. Mean blood pressures were calculated for each arm to derive mean systolic and diastolic differences, and to estimate point prevalence of predefined magnitudes of difference. A total of 101 participants were recruited. Mean age was 66 years (standard deviation [SD] = 13.9 years); 59% were male, and mean blood pressure was 138/79 mmHg (SD = 15/10 mmHg). Ten participants (10%; 95% confidence interval [CI] = 4 to 16) had a systolic inter-arm difference > or =10 mmHg; 29 (29%; 95% CI = 20 to 38) had a diastolic difference >/=5 mmHg; and three (3%; 95% CI = 0 to 6) a diastolic difference > or =10 mmHg. No confounding variable was observed to account for the magnitude of an inter-arm difference. A systolic inter-arm difference > or =10 mmHg was observed in 10% of patients with diabetes. Failure to recognise this would misclassify half of these as normotensive rather than hypertensive using the lower-reading arm. New patients with type 2 diabetes should be screened for an inter-arm blood pressure difference.

  8. Choice of marker for assessment of RV dysfunction in acute pulmonary embolism : NT-proBNP, pulmonary artery systolic pressure, mean arterial pressure, or blood pressure index.

    Science.gov (United States)

    Ates, H; Ates, I; Kundi, H; Yilmaz, F M

    2017-12-01

    We aimed to examine the value of NT-proBNP, pulmonary artery systolic pressure (PASP), blood pressure index (BPI), and mean arterial pressure (MAP) in the determination of right ventricular dysfunction (RVD) in patients with acute pulmonary embolism (APE). A total of 547 patients diagnosed with APE were included in the study. Demographic characteristics and comorbid conditions of patients were recorded in patient files. For blood pressure measurement, a calibrated digital blood pressure monitor was used at regular intervals. Blood samples were taken from patients at the time of admission for hemogram, biochemical, and hemostasis blood tests. Echocardiography was performed on all patients to detect RVD and evaluate pulmonary artery pressure. PASP (p blood pressure (p blood cell (p AUC ± SE = 0.975 ± 0.006; p < 0.001) was found to be the best predictor of RVD with a higher sensitivity (92.8%) and specificity (100%). We found that BPI had a better diagnostic discrimination for RVD compared with PASP and NT-proBNP.

  9. Relationship Between Urinary Nitrate Excretion and Blood Pressure in the InChianti Cohort.

    Science.gov (United States)

    Smallwood, Miranda J; Ble, Alessandro; Melzer, David; Winyard, Paul G; Benjamin, Nigel; Shore, Angela C; Gilchrist, Mark

    2017-07-01

    Inorganic nitrate from the oxidation of endogenously synthesized nitric oxide (NO) or consumed in the diet can be reduced to NO via a complex enterosalivary circulation pathway. The relationship between total nitrate exposure by measured urinary nitrate excretion and blood pressure in a large population sample has not been assessed previously. For this cross-sectional study, 24-hour urinary nitrate excretion was measured by spectrophotometry in the 919 participants from the InChianti cohort at baseline and blood pressure measured with a mercury sphygmomanometer. After adjusting for age and sex only, diastolic blood pressure was 1.9 mm Hg lower in subjects with ≥2 mmol urinary nitrate excretion compared with those excreting nitrate in 24 hours: systolic blood pressure was 3.4 mm Hg (95% confidence interval (CI): -3.5 to -0.4) lower in subjects for the same comparison. Effect sizes in fully adjusted models (for age, sex, potassium intake, use of antihypertensive medications, diabetes, HS-CRP, or current smoking status) were marginally larger: systolic blood pressure in the ≥2 mmol urinary nitrate excretion group was 3.9 (CI: -7.1 to -0.7) mm Hg lower than in the comparison nitrate exposure are associated with lower blood pressure. These differences are at least equivalent to those seen from substantial (100 mmol) reductions in sodium intake. © American Journal of Hypertension, Ltd 2017. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  10. Circadian melatonin concentration rhythm is lost in pregnant women with altered blood pressure rhythm.

    Science.gov (United States)

    Tranquilli, A L; Turi, A; Giannubilo, S R; Garbati, E

    2004-03-01

    We assessed the correlation between the rhythm of melatonin concentration and circadian blood pressure patterns in normal and hypertensive pregnancy. Ambulatory 24-h blood pressure and blood samples every 4 h were monitored in 16 primigravidae who had shown an abnormal circadian blood pressure pattern (eight pre-eclamptic and eight normotensive) in pregnancy and 6-12 months after pregnancy. The circadian rhythm was analyzed by chronobiological measures. Eight normotensive women with maintained blood pressure rhythm served as controls. During pregnancy, melatonin concentration was significantly higher in pre-eclamptic than in normotensive women (pre-eclampsia, 29.4 +/- 1.9 pg/ml, normotensin, altered rhythm, 15.6 +/- 2.1; controls, 22.7 +/- 1.8; p lost in all pregnant women with loss of blood pressure rhythm. After pregnancy, normotensive women showed a reappearance of both melatonin and blood pressure rhythm, whereas pre-eclamptic women showed a reappearance of blood pressure but not melatonin rhythm. The loss of blood pressure rhythm in pregnancy is consistent with the loss of melatonin concentration rhythm. In pre-eclamptic women, the normalization of blood pressure rhythm, while melatonin rhythm remained altered, suggests a temporal or causal priority of circadian concentration of melatonin in the determination of blood pressure trend.

  11. DASH diet to lower high blood pressure

    Science.gov (United States)

    ... patientinstructions/000770.htm DASH diet to lower high blood pressure To use the sharing features on this page, ... Hypertension. The DASH diet can help lower high blood pressure and cholesterol and other fats in your blood. ...

  12. The relationship between blood viscosity and blood pressure in a random sample of the population aged 55 to 74 years.

    Science.gov (United States)

    Fowkes, F G; Lowe, G D; Rumley, A; Lennie, S E; Smith, F B; Donnan, P T

    1993-05-01

    Blood viscosity is elevated in hypertensive subjects, but the association of viscosity with arterial blood pressure in the general population, and the influence of social, lifestyle and disease characteristics on this association, are not established. In the Edinburgh Artery Study, 1592 men and women aged 55-74 years selected randomly from the general population attended a university clinic. A fasting blood sample was taken for the measurement of blood viscosity and its major determinants (haematocrit, plasma viscosity and fibrinogen). Systolic pressure was related univariately to blood viscosity (P viscosity (P index. Diastolic pressure was related univariately to blood viscosity (P viscosity (P viscosity and systolic pressure was confined to males. Blood viscosity was associated equally with systolic and diastolic pressures in males, and remained independently related on multivariate analysis adjusting for age, sex, body mass index, social class, smoking, alcohol intake, exercise, angina, HDL and non-HDL cholesterol, diabetes mellitus, plasma viscosity, fibrinogen, and haematocrit.

  13. Circadian blood pressure patterns and blood pressure control in patients with chronic kidney disease.

    Science.gov (United States)

    Di Daniele, Nicola; Fegatelli, Danilo Alunni; Rovella, Valentina; Castagnola, Veronica; Gabriele, Marco; Scuteri, Angelo

    2017-12-01

    Hypertension is a major risk factor for chronic kidney disease (CKD), and CKD progression is associated with suboptimal blood pressure (BP) control. Here we evaluate the impact of CKD on the attainment of BP control and the circadian BP profile in older subjects. In this observational study, we studied 547 patients referred to the hypertension clinic, of whom 224 (40.9%) had CKD. Blood pressure (BP) control and circadian BP patterns were evaluated by 24-hour ambulatory BP monitoring. Circadian BP variability was measured as the within-subject SD of BP, the percentage of measurements exceeding normal values, hypotension, and dipping status. The attainment of adequate BP control was similar in subjects with or without CKD (around 31%). Logistic regression analysis indicated that CKD was not a determinant of adequate BP control (OR 1.004; 95% CI 0.989-1.019; p = 0.58). Patients with CKD presented as twice as higher prevalence of reverse dipper (night-time peak) for systolic BP and episodes of hypotension during daytime, independently of BP control. Knowledge of the circadian pattern of BP in hypertensive subjects with CKD could inform better than attainment of BP target about risky condition for CKD progression and cognitive decline and allow a more personalized antihypertensive treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Prevalence of pre-high blood pressure and high blood pressure among non-overweight children and adolescents using international blood pressure references in developed regions in China.

    Science.gov (United States)

    Tian, Changwei; Xu, Shuang; Wang, Hua; Wang, Wenming; Shen, Hui

    2017-09-01

    There is a lack of data on the prevalence of pre-high blood pressure (PreHBP) and high blood pressure (HBP), based on recent international blood pressure references, in non-overweight children and adolescents. To describe the prevalence of PreHBP and HBP in non-overweight children and adolescents in developed regions of China. In total, 588 097 non-overweight children and adolescents aged 6-17 years from the National Surveys on Chinese Students' Constitution and Health in 2015 were included. The prevalence of PreHBP was 13.41% and subjects in urban areas had a higher prevalence of PreHBP (14.14%) than those in rural areas (12.92%). Subjects in regions with a high (13.56%) or moderate (13.61%) socioeconomic status showed a higher prevalence of PreHBP than those in regions with a relatively low socioeconomic status (12.76%). A similar pattern was found for the prevalence of HBP, and the prevalence of HBP was 18.25% for all participants, 20.55% for subjects in urban areas, 16.71% in rural areas, 18.76% in high socioeconomic areas, 18.62% in moderate socioeconomic areas and 16.70% in relatively low socioeconomic areas. A large proportion of non-overweight children and adolescents had elevated blood pressure and there were urban-rural and socioeconomic disparities in the prevalence of elevated blood pressure.

  15. Inter-arm Differences in Simultaneous Blood Pressure Measurements in Ambulatory Patients without Cardiovascular Diseases.

    Science.gov (United States)

    Kim, Kyoung Bog; Oh, Mi Kyeong; Kim, Haa Gyoung; Ki, Ji Hoon; Lee, Soo Hee; Kim, Su Min

    2013-03-01

    It has traditionally been known that there is normally a difference in blood pressure (BP) between the two arms; there is at least 20 mm Hg difference in the systolic blood pressure (SBP) and 10 mm Hg difference in the diastolic blood pressure (DBP). However, recent epidemiologic studies have shown that there are between-arm differences of arm differences in simultaneous BP measurements obtained from ambulatory patients without cardiovascular diseases and to identify the factors associated these differences. We examined 464 patients who visited the outpatient clinic of Gangneung Asan Hospital clinical department. For the current analysis, we excluded patients with ischemic heart disease, stroke, arrhythmia, congestive heart failure, or hyperthyroidism. Simultaneous BP measurements were obtained using the Omron MX3 BP monitor in both arms. The inter-arm difference (IAD) in BP was expressed as the relative difference (right-arm BP [R] minus left-arm BP [L]: R - L) and the absolute difference (|R - L|). The mean absolute IAD in SBP and DBP were 3.19 ± 2.38 and 2.41 ± 1.59 mm Hg, respectively, in men and 2.61 ± 2.18 and 2.25 ± 2.01 mm Hg, respectively, in women. In men, there were 83.8% of patients with the IAD in SBP of ≤ 6 mm Hg, 98.1% with the IAD in SBP of ≤ 10 mm Hg, 96.5% with the IAD in DBP of ≤ 6 mm Hg and 0% with the IAD in DBP of > 10 mm Hg. In women, 89.6% of patients had IAD in SBP of ≤ 6 mm Hg, 92.1% with IAD in DBP of ≤ 6 mm Hg, and 0% with IAD in SBP of > 10 mm Hg or IAD in DBP of > 10 mm Hg. Gangneung Asan Hospital clinical series of patients showed that the absolute IAD in SBP had a significant correlation with cardiovascular risk factors such as the 10-year Framingham cardiac risk scores and higher BP in men and higher BP in women. However, the absolute IAD in SBP and DBP had no significant correlation with the age, obesity, smoking, drinking, hyperlipidemia, diabetes, metabolic syndrome, and renal function. Our results showed that there

  16. Effects of Ramadan fasting on blood pressure in hypertensive patients: a systematic review

    Directory of Open Access Journals (Sweden)

    Maryam Alinezhad-Namaghi

    2016-03-01

    Full Text Available Ramadan is a holy month for Muslims and fasting in this month is the rule for any healthy matured person. Nutritional and behavioral changes occurred during Ramadan fasting may lead to several physiological change, such as blood pressure (2. Studies evaluated the effects of Ramadan fasting on blood pressure in hypertensive patients, are scarce and reported inadequate results. In this paper a systematic review was performed to accumulate the results of published literature designed to evaluate blood pressure changes in hypertensive patients due to Ramadan fasting. All prospective, English studies which evaluated the effects of Ramadan fasting on blood pressure in hypertensive patients and measured systolic and diastolic blood pressure twice at least ( before Ramadan and during last week of Ramadan or after Ramadan fasting were included in systematic review . Five studies reported the effect of Ramadan fasting on blood pressure in hypertensive patients in full text. Although significant reduction in systolic blood pressure during Ramadan fasting were seen in 3 studies (3-5, other 3 studies reported no significant difference between systolic blood pressure before and after Ramadan fasting (6, 7. Among 6 studies that reviewed in this paper, 4 studies reported no significant changes in diastolic blood pressure (4, 6, 7. While 2 other studies reported significant reduction in systolic blood pressure after Ramadan fasting (3, 5. This systematic review suggested that Ramadan fasting can be safe in treated essential hypertensive patients with continuation of previous medications. Also it can improve systolic and diastolic blood pressures.

  17. Methylmercury and elemental mercury differentially associate with blood pressure among dental professionals

    Science.gov (United States)

    Goodrich, Jaclyn M.; Wang, Yi; Gillespie, Brenda; Werner, Robert; Franzblau, Alfred; Basu, Niladri

    2013-01-01

    Methylmercury-associated effects on the cardiovascular system have been documented though discrepancies exist, and most studied populations experience elevated methylmercury exposures. No paper has investigated the impact of low-level elemental (inorganic) mercury exposure on cardiovascular risk in humans. The purpose of this study was to increase understanding of the association between mercury exposure (methylmercury and elemental mercury) and blood pressure measures in a cohort of dental professionals that experience background exposures to both mercury forms. Dental professionals were recruited during the 2010 Michigan Dental Association Annual Convention. Mercury levels in hair and urine samples were analyzed as biomarkers of methylmercury and elemental mercury exposure, respectively. Blood pressure (systolic, diastolic) was measured using an automated device. Distribution of mercury in hair (mean, range: 0.45, 0.02–5.18 μg/g) and urine (0.94, 0.03–5.54 μg/L) correspond well with the US National Health and Nutrition Examination Survey. Linear regression models revealed significant associations between diastolic blood pressure (adjusted for blood pressure medication use) and hair mercury (n = 262, p = 0.02). Urine mercury results opposed hair mercury in many ways. Notably, elemental mercury exposure was associated with a significant systolic blood pressure decrease (n = 262, p = 0.04) that was driven by the male population. Associations between blood pressure and two forms of mercury were found at exposure levels relevant to the general population, and associations varied according to type of mercury exposure and gender. PMID:22494934

  18. Blood Pressure Matters: Keep Hypertension in Check

    Science.gov (United States)

    ... 2016 Print this issue Blood Pressure Matters Keep Hypertension in Check En español Send us your comments ... 1 in 3 adults in the U.S. has high blood pressure, but many don’t realize it. High blood ...

  19. Validation of the SEJOY BP-1307 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Lei, Lei; Chen, Yi; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2017-12-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor SEJOY BP-1307 (also called JOYTECH DBP-1307) for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese individuals (13 women, 45.1 years of mean age) using a mercury sphygmomanometer (two observers) and the SEJOY BP-1307 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The average±SD of the device-observer differences was 0.2±4.1 and -1.7±4.7 mmHg for systolic and diastolic blood pressure, respectively. The SEJOY BP-1307 device achieved the criteria in both part 1 and part 2 of the validation study. The SEJOY upper-arm blood pressure monitor BP-1307 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  20. High Blood Pressure: Unique to Older Adults

    Science.gov (United States)

    ... our e-newsletter! Aging & Health A to Z High Blood Pressure Hypertension Unique to Older Adults This section provides ... Pressure Targets are Different for Very Old Adults High blood pressure (also called hypertension) increases your chance of having ...

  1. Revalidation of game for teaching blood pressure auscultatory measurement: a pilot study.

    Science.gov (United States)

    Bellan, Margarete Consorti; Alves, Vanessa Cortez; Neves, Mayza Luzia Dos Santos; Lamas, José Luiz Tatagiba

    2017-01-01

    To adapt a pre-existing educational game, making it specific to the teaching of blood pressure auscultatory measurement, and to apply this game in a pilot study. The original game cards were altered by the authors and submitted to content validation by six experts in the field. After redesigns, the game was applied to 30 subjects, who answered a questionnaire (pre-test and post-test) on auscultatory measurement. Data were analyzed descriptively and by the paired Student's t-test and paired Wilcoxon test. Throughout the content validation process, 17 of the 28 original cards were modified. Of these 17 cards, 13 obtained 80% agreement, and the rest were modified according to the judges' suggestions. The obtained grades significantly increased between pre- and the post-test. It was concluded that the reformulated game presented satisfactory evidence of content validity. Its use as a teaching-learning method was effective for this sample.

  2. Validation of the Omron HEM-7201 upper arm blood pressure monitor, for self-measurement in a high-altitude environment, according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Cho, K; Tian, M; Lan, Y; Zhao, X; Yan, L L

    2013-08-01

    Few studies have been conducted on blood pressure monitors and their use at high altitude. This study is the first to evaluate the accuracy of an automatic blood pressure monitor in a high-altitude environment following a standard validation protocol. The Omron HEM-7201 upper arm blood pressure monitor was tested for accuracy in Lhasa, Tibet, China (3650 m above sea level) according to the European Society of Hypertension International Protocol revision 2010 (ESH-IP2). Thirty-three participants received 9-10 sequential blood pressure measurements alternating between a mercury sphygmomanometer and the device. The mean device-observer measurement difference was 1.0±5.9 mm Hg for systolic blood pressure (SBP) and -3.1±4.6 mm Hg for diastolic blood pressure (DBP). Of the 99 measurement pairs analyzed, 72, 90 and 97 device readings were within 5, 10 and 15 mm Hg, respectively, of the observer measurements for SBP, and 68, 92 and 99 readings for DBP. The number of participants with at least two out of three measurements within 5 mm Hg was 27 for SBP and 25 for DBP. Three participants had no measurements within 5 mm Hg for either SBP or DBP. As a result, the Omron HEM-7201 passes the ESH-IP2 validation criteria and can therefore be recommended for use in adults in this setting.

  3. Cost-effectiveness of Intensive Blood Pressure Management

    DEFF Research Database (Denmark)

    Richman, Ilana B; Fairley, Michael; Jørgensen, Mads Emil

    2016-01-01

    Importance: Among high-risk patients with hypertension, targeting a systolic blood pressure of 120 mm Hg reduces cardiovascular morbidity and mortality compared with a higher target. However, intensive blood pressure management incurs additional costs from treatment and from adverse events......-effectiveness of intensive blood pressure management among 68-year-old high-risk adults with hypertension but not diabetes. We used the Systolic Blood Pressure Intervention Trial (SPRINT) to estimate treatment effects and adverse event rates. We used Centers for Disease Control and Prevention Life Tables to project age...... and accrued $155 261 in lifetime costs, while intensive management yielded 10.5 QALYs and accrued $176 584 in costs. Intensive blood pressure management cost $23 777 per QALY gained. In a sensitivity analysis, serious adverse events would need to occur at 3 times the rate observed in SPRINT and be 3 times...

  4. Home and Office Blood Pressure Control among Treated Hypertensive Patients in Japan: Findings from the Japan Home versus Office Blood Pressure Measurement Evaluation (J-HOME Study

    Directory of Open Access Journals (Sweden)

    Nariyasu Mano

    2010-02-01

    Full Text Available Appropriate control of blood pressure (BP is essential for prevention of future cardiovascular events. However, BP control among treated hypertensive patients has been insufficient. Recently, the usefulness of self-measured BP at home (home BP measurement for the management of hypertension has been reported in many studies. We evaluated BP control both at home and in the office among treated hypertensive patients in primary care settings in Japan (the J-HOME study. We found poor control of home and office BPs and clarified some factors affecting control. We also examined factors associated with the magnitude of the white-coat effect, the morning–evening BP difference, and home heart rate in this J-HOME study.

  5. Inner ocular blood flow responses to an acute decrease in blood pressure in resting humans

    International Nuclear Information System (INIS)

    Ikemura, Tsukasa; Kashima, Hideaki; Yamaguchi, Yuji; Miyaji, Akane; Hayashi, Naoyuki

    2015-01-01

    Whether inner ocular vessels have an autoregulatory response to acute fluctuations in blood pressure is unclear. We tried to examine the validity of acute hypotension elicited by thigh-cuff release as to assess the dynamic autoregulation in the ocular circulation. Blood flow velocity in the superior nasal and inferior temporal retinal arterioles, and in the retinal and choroidal vasculature were measured with the aid of laser speckle flowgraphy before and immediately after an acute decrease in blood pressure in 20 healthy subjects. Acute hypotension was induced by a rapid release of bilateral thigh occlusion cuffs that had been inflated to 220 mmHg for 2 min. The ratio of the relative change in retinal and choroidal blood flow velocity to the relative change in mean arterial blood pressure (MAP) was calculated. Immediately after cuff release, the MAP and blood flows in the all ocular target vessels decreased significantly from the baseline values obtained before thigh-cuff release. The ratio of the relative change in inner ocular blood flow velocity to that in the MAP exceeded 1% / %mmHg. An explicit dynamic autoregulation in inner ocular vessels cannot be demonstrated in response to an acute hypotension induced by the thigh-cuff release technique. (paper)

  6. The correlation between serum leptin and blood pressure after exposure to noise at work

    Directory of Open Access Journals (Sweden)

    Muayad S Rahma

    2013-01-01

    Full Text Available Several epidemiologic studies have reported that exposure to noise is associated with cardiovascular disease. The increased body weight is often associated with metabolic as well as increased blood pressure. The aim of this study is to investigate the correlation between the elevation of blood pressure and serum leptin hormones due to the effects of noise in the work place. A total of 80 volunteer males where included in this study with an age range between of 20 and 45 years, they were divided in two groups equally, the 1 st group were exposed to noise in the workplace while the 2 nd group were not. The individual noise exposure was determined by using a sound level meter. The range of noise was 80-100 dBA. Body Mass Index was also taken for each individual by a standard measure, blood pressure was measured by OMRON sphygmomanometer and serum leptin was measured through venous blood sample analysis enzyme linked immunosorbent assay. Spearman rank order correlation was used to examine the correlations between Blood pressure value (Systolic, Diastolic and Leptin. All the relationships between parameters showed a positive correlation. Systolic and diastolic blood pressure values had a significant correlation to leptin hormone level in comparison to the control. There was a significant relation between leptin and blood pressure. leptin effects on the sympathetic nervous system may provide a partial explanation. Therefore, Leptin might have diverse cardiovascular actions.

  7. Lean mass influences overnight changes in hydration, blood pressure and strength in community-dwelling older women.

    Science.gov (United States)

    Benton, Melissa J; Schlairet, Maura C

    2016-10-01

    We evaluated the hypothesis that greater lean mass promotes better overnight hydration, improved postural blood pressure and greater strength. Thirty women, aged 71 ± 0.9 years (mean ± SE), completed one measurement in a euhydrated state and another the following morning after an overnight fast. Measurements included hydration, lean mass, orthostatic blood pressure and strength. Participants were grouped by fat-free mass index (FFMI), with cut-points defined as low (blood pressure. On day 1, women with low FFMI experienced significant postural systolic blood pressure changes from sitting to standing (-11.3 ± 4.0 mmHg, p postural blood pressure and loss of strength that increases the risk for early morning falls.

  8. Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device

    Directory of Open Access Journals (Sweden)

    Jong-Gu Choi

    2011-01-01

    Full Text Available To measure precise blood pressure (BP and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.

  9. High Blood Pressure

    Science.gov (United States)

    ... factors Diabetes High blood pressure Family history Obesity Race/ethnicity Full list of causes and risk factors ... give Give monthly Memorials and tributes Donate a car Donate gently used items Stock donation Workplace giving ...

  10. High Blood Pressure

    Science.gov (United States)

    ... kidney disease, diabetes, or metabolic syndrome Read less Unhealthy lifestyle habits Unhealthy lifestyle habits can increase the risk of high blood pressure. These habits include: Unhealthy eating patterns, such as eating too much sodium ...

  11. Association between general and abdominal obesity with high blood pressure: difference between genders.

    Science.gov (United States)

    Silva, Alison O; Silva, Micaelly V; Pereira, Lisley K N; Feitosa, Wallacy M N; Ritti-Dias, Raphael M; Diniz, Paula R B; Oliveira, Luciano M F T

    2016-01-01

    To assess the association between general and abdominal obesity with high blood pressure in adolescents of both genders from the public school system. This was an epidemiological, descriptive, exploratory study, with a quantitative approach and local scope whose sample consisted of 481 high school students (aged 14-19), selected by using a random cluster sampling strategy. Blood pressure was measured through the use of automated monitor and was considered high when the pressure values were at or above the 95th percentile. The analyses were performed using the chi-squared test and binary logistic regression. The prevalence of high blood pressure was 6.4%, and it was higher among boys (9.0% vs. 4.7%, phigh blood pressure was associated with general (OR=6.4; phigh blood pressure only in boys, regardless of age. Copyright © 2015 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  12. Use of paravascular admittance waveforms to monitor relative change in arterial blood pressure

    Science.gov (United States)

    Zielinski, Todd M.; Hettrick, Doug; Cho, Yong

    2010-04-01

    Non-invasive methods to monitor ambulatory blood pressure often have limitations that can affect measurement accuracy and patient adherence [1]. Minimally invasive measurement of a relative blood pressure surrogate with an implantable device may provide a useful chronic diagnostic and monitoring tool. We assessed a technique that uses electrocardiogram and paravascular admittance waveform morphology analysis to one, measure a time duration (vascular tone index, VTI in milliseconds) change from the electrocardiogram R-wave to admittance waveform peak and two, measure the admittance waveform minimum, maximum and magnitude as indicators of change in arterial compliance/distensibility or pulse pressure secondary to change in afterload. Methods: Five anesthetized domestic pigs (32 ± 4.2 kg) were used to study the effects of phenylephrine (1-5 ug/kg/min) on femoral artery pressure and admittance waveform morphology measured with a quadrapolar electrode array catheter placed next to the femoral artery to assess the relative change in arterial compliance due to change in peripheral vascular tone. Results: Statistical difference was observed (p blood pressure may be suitable for implantable devices to detect progression of cardiovascular disease such as hypertension.

  13. Reproducibility of blood pressure variation in older ambulatory and bedridden subjects.

    Science.gov (United States)

    Tsuchihashi, Takuya; Kawakami, Yasunobu; Imamura, Tsuyoshi; Abe, Isao

    2002-06-01

    We investigated the influence of ambulation on the reproducibility of circadian blood pressure variation in older nursing home residents. Ambulatory blood pressure monitoring was performed twice in 37 older nursing home residents. Nursing home in Japan. Subjects included 18 ambulatory nursing home residents who had no limitation on physical activity and 19 bedridden residents who did not participate in physical activity. Twenty-four-hour, daytime, and nighttime blood pressure levels and their variability. The 24-hour and daytime variability of systolic blood pressure (SBP) was significantly greater in ambulatory than in bedridden subjects, whereas nighttime variability was similar. Significant correlations in SBP averaged for the whole day, daytime, and nighttime were observed between the two examinations in ambulatory (r =.80-.83) and bedridden (r =.83-.91) subjects, but the variabilities of SBP for the whole day and during the daytime of the first measurement were correlated with those of the second measurement in bedridden (r =.67 and r =.47, respectively) but not in ambulatory (r =.39 and r =.28, respectively) subjects. Significant correlations were found between the nocturnal SBP changes at two occasions in both ambulatory (r =.50) and bedridden (r =.51) subjects, but the dipper versus nondipper profiles, defined as reduction in SBP of greater than 10% versus not, showed low reproducibility in ambulatory subjects; five ambulatory (28%) and one bedridden (5%) subjects showed divergent profiles between the two examinations. The reproducibility of blood pressure variation in nursing home residents is influenced by ambulation.

  14. Validation of the iHealth BP3 upper-arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Chen, Can; Shang, Fujun; Wang, Jiepin; Chen, Jianghong; Ji, Na; Wan, Yi

    2012-12-01

    This study aimed to evaluate the performance of the iHealth BP3 upper-arm blood pressure monitor, which is designed for clinic use and self-measurement of blood pressure using Apple touch devices as an interface. The European Society of Hypertension International Protocol (ESH-IP) revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. Ninty-nine couples of test device and reference blood pressure measurements were obtained during the study (three pairs for each of the 33 participants). The 33 participants, age 47.1±12.3 years (age range 27-69 years) and arm circumference 30.0±4.4 cm, had a mean systolic blood pressure (SBP) of 143.9±27.4 mmHg and a mean diastolic blood pressure (DBP) of 90.1±18.3 mmHg. The device passed all of the requirements fulfilling the standards of the protocol, and the mean±SD device-observer difference was 2.8±4.2 mmHg for SBP and -0.4±3.5 mmHg for DBP. According to the results of the validation study on the basis of the ESH-IP revision 2010, the iHealth BP3 can be recommended for clinic use and self-measurement in an adult population. © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.

  15. Validation of the blood pressure measurement device Erkameter 125 PRO according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Beime, Beate; Deutsch, Cornelia; Krüger, Ralf; Zimmermann, Erik; Bramlage, Peter

    2016-12-01

    The aim of the present study was to validate the blood pressure (BP) measurement device Erkameter 125 PRO according to the International Protocol revision 2010 of the European Society of Hypertension (ESH-IP2). In 33 patients aged 32-79 years, BP measurements were performed alternately using the Erkameter 125 PRO and the reference mercury sphygmomanometer according to ESH-IP revision 2010. For the analysis, a total of 99 comparisons were included. All absolute differences between the test device and the reference were within 10 mmHg for systolic blood pressure (SBP), and all except one for diastolic blood pressure (DBP). A total of 93 out of 99 comparisons for SBP showed an absolute difference within 5 mmHg and 92 out of 99 for DBP. The mean±SD difference between the Erkameter 125 PRO and the standard reference was -0.5±3.5 mmHg for SBP and 0.5±3.5 mmHg for DBP. As to part 2 of ESH-IP 2010, all patients had a minimum of two out of three measurements within 5 mmHg difference for SBP and 31 out of 33 patients for DBP. The Erkameter 125 PRO fulfilled the requirements of parts 1 and 2 of the ESH-IP revision 2010 and can be recommended for office BP measurements in adults.

  16. Blood pressure in ICSI-conceived adolescents

    NARCIS (Netherlands)

    Belva, F.; Roelants, M.; de Schepper, J.; Roseboom, T. J.; Bonduelle, M.; Devroey, P.; Painter, R. C.

    2012-01-01

    Do young adolescents conceived by ICSI display a higher blood pressure than spontaneously conceived (SC) adolescents? In our study, 14-year-old male and female ICSI teenagers were not found to have increased blood pressure at rest. Only limited data are available regarding the cardiovascular risk of

  17. Trend of blood pressure in hypertensive and normotensive volunteers during Ramadan fasting.

    Science.gov (United States)

    Norouzy, Abdolreza; Hasanzade Daloee, Mahdi; Khoshnasab, Amir Hosein; Khoshnasab, Adeleh; Farrokhi, Javad; Nematy, Mohsen; Safarian, Mohammad; Nezafati, Pouya; Alinezhad-Namaghi, Maryam

    2017-10-01

    It is believed that Ramadan fasting regulates blood pressure, heart rate, and other cardiovascular risk factors. This study aimed to investigate the effect of Ramadan fasting on ambulatory blood pressure in hypertensive patients. This prospective, observational study was carried out in two groups: one group included hypertensive patients treated with two antihypertensive agents (n=6) and the other group included healthy individuals (n=12). We performed 24-h blood pressure monitoring at four time points: before Ramadan, during the first and last 10 days of Ramadan, and 1 month after Ramadan. All hypertensive patients followed their twice-daily treatment regimen. Mean 24-h blood pressure (as well as mean blood pressure values during awake and sleep periods), body weight, and waist circumference were measured in the two groups. There were no significant differences in the trends of systolic and diastolic blood pressure between the hypertensive and nonhypertensive groups during Ramadan and 1 month after it. However, the trends of variations in heart rate and body weight were not significantly different in the two groups (PRamadan in hypertensive patients (P=0.018), whereas it improved during the post-Ramadan period in comparison with the second period of measurements (P=0.019). Furthermore, there was a significant decline in heart rate during the post-Ramadan measurement compared with that before Ramadan in the nonhypertensive group (P=0.008).In addition, there was a significant weight gain in the third period in comparison with the previous period in the hypertensive group (73.1±11 vs. 72.2±12; P=0.011). This finding indicates that Ramadan fasting might be nonthreatening for patients with essential hypertension if the treatment regimen is complied with.

  18. Anxiety and blood pressure prior to dental treatment.

    NARCIS (Netherlands)

    Benjamins, C.; Schuurs, A.H.; Asscheman, H.; Hoogstraten, J.

    1990-01-01

    Assessed dental anxiety and blood pressure immediately prior to a dental appointment in 24 patients attending a university dental clinic or a clinic for anxious dental patients in the Netherlands. Blood pressure was assessed by 2 independent methods, and the interchangeability of the blood-pressure

  19. Dietary fiber and blood pressure control.

    Science.gov (United States)

    Aleixandre, A; Miguel, M

    2016-04-01

    In the past few years, new strategies to control blood pressure levels are emerging by developing new bioactive components of foods. Fiber has been linked to the prevention of a number of cardiovascular diseases and disorders. β-Glucan, the main soluble fiber component in oat grains, was initially linked to a reduction in plasma cholesterol. Several studies have shown afterward that dietary fiber may also improve glycaemia, insulin resistance and weight loss. The effect of dietary fiber on arterial blood pressure has been the subject of far fewer studies than its effect on the above-mentioned variables, but research has already shown that fiber intake can decrease arterial blood pressure in hypertensive rats. Moreover, certain fibers can improve arterial blood pressure when administered to hypertensive and pre-hypertensive subjects. The present review summarizes all those studies which attempt to establish the antihypertensive effects of dietary fiber, as well as its effect on other cardiovascular risk factors.

  20. Racial Differences in Abnormal Ambulatory Blood Pressure Monitoring Measures: Results From the Coronary Artery Risk Development in Young Adults (CARDIA) Study

    Science.gov (United States)

    Lewis, Cora E.; Diaz, Keith M.; Carson, April P.; Kim, Yongin; Calhoun, David; Yano, Yuichiro; Viera, Anthony J.; Shimbo, Daichi

    2015-01-01

    BACKGROUND Several ambulatory blood pressure monitoring (ABPM) measures have been associated with increased cardiovascular disease risk independent of clinic blood pressure (BP). African Americans have higher clinic BP compared with Whites but few data are available on racial differences in ABPM measures. METHODS We compared ABPM measures between African American (n = 178) and White (n = 103) participants at the Year 5 Coronary Artery Risk Development in Young Adults study visit. BP was measured during a study visit and the second and third measurements were averaged. ABPM was conducted over the following 24 hours. RESULTS Mean ± SD age of participants was 29.8±3.8 years and 30.8±3.5 years for African Americans and Whites, respectively. Mean daytime systolic BP (SBP) was 3.90 (SD 1.18) mm Hg higher among African Americans compared with Whites (P ABPM was higher among African Americans compared with Whites. CONCLUSIONS These data suggest racial differences in several ABPM measures exist. PMID:25376639

  1. Aortic and peripheral blood pressure during isometric and dynamic exercise

    NARCIS (Netherlands)

    Blum, V.; Carrière, E.G.J.; Kolsters, W.; Mosterd, W.L.; Schiereck, P.; Wesseling, K.H.

    1997-01-01

    The purpose of this study was to compare aortic blood pressure (AOR) to peripheral measurements by the Riva-Rocci/Korotkov (RRK) and Finapres continuous finger pressure (FIN) methods during dynamic and static exercise. A tip manometer was introduced in the ascending aorta after coronary angiography

  2. Autologous Transfusion of Stored Red Blood Cells Increases Pulmonary Artery Pressure

    Science.gov (United States)

    Pinciroli, Riccardo; Stowell, Christopher P.; Wang, Lin; Yu, Binglan; Fernandez, Bernadette O.; Feelisch, Martin; Mietto, Cristina; Hod, Eldad A.; Chipman, Daniel; Scherrer-Crosbie, Marielle; Bloch, Kenneth D.; Zapol, Warren M.

    2014-01-01

    Rationale: Transfusion of erythrocytes stored for prolonged periods is associated with increased mortality. Erythrocytes undergo hemolysis during storage and after transfusion. Plasma hemoglobin scavenges endogenous nitric oxide leading to systemic and pulmonary vasoconstriction. Objectives: We hypothesized that transfusion of autologous blood stored for 40 days would increase the pulmonary artery pressure in volunteers with endothelial dysfunction (impaired endothelial production of nitric oxide). We also tested whether breathing nitric oxide before and during transfusion could prevent the increase of pulmonary artery pressure. Methods: Fourteen obese adults with endothelial dysfunction were enrolled in a randomized crossover study of transfusing autologous, leukoreduced blood stored for either 3 or 40 days. Volunteers were transfused with 3-day blood, 40-day blood, and 40-day blood while breathing 80 ppm nitric oxide. Measurements and Main Results: The age of volunteers was 41 ± 4 years (mean ± SEM), and their body mass index was 33.4 ± 1.3 kg/m2. Plasma hemoglobin concentrations increased after transfusion with 40-day and 40-day plus nitric oxide blood but not after transfusing 3-day blood. Mean pulmonary artery pressure, estimated by transthoracic echocardiography, increased after transfusing 40-day blood (18 ± 2 to 23 ± 2 mm Hg; P transfusing 3-day blood (17 ± 2 to 18 ± 2 mm Hg; P = 0.5). Breathing nitric oxide decreased pulmonary artery pressure in volunteers transfused with 40-day blood (17 ± 2 to 12 ± 1 mm Hg; P Transfusion of autologous leukoreduced blood stored for 40 days was associated with increased plasma hemoglobin levels and increased pulmonary artery pressure. Breathing nitric oxide prevents the increase of pulmonary artery pressure produced by transfusing stored blood. Clinical trial registered with www.clinicaltrials.gov (NCT 01529502). PMID:25162920

  3. Differences Between Right and Left Arm Blood Pressures in the Elderly

    OpenAIRE

    Hashimoto, Fred; Hunt, William C.; Hardy, Linda

    1984-01-01

    Recommendations vary on whether blood pressures should be measured in the right or in the left arm because no frequency distributions for a pressure difference between the arms exist. We took a total of 12 blood pressure determinations in both arms of 174 elderly persons and analyzed the data by a least-squares components of variance method. The mean difference between the arms (right minus left) was 0.93 mm of mercury for systole and 0.70 mm of mercury for diastole. For systole the proportio...

  4. Effects of occupational noise exposure on changes in blood pressure of workers

    Directory of Open Access Journals (Sweden)

    Hossein Ali Yousefi Rizi

    2013-01-01

    Full Text Available    BACKGROUND: In most industries, workers are exposed to loud noise. Noise is considered as a nonspecific biological stressor that have adverse effects on human physiology. It is associated with hypertension which is in turn one of the most important preventable risk factors of cardiovascular disorders. This study aimed to evaluate the effects of noise on changes of workers' blood pressure.    METHODS: This cross-sectional study was performed on 90 individuals who were exposed to noise at one of the industries in Isfahan, Iran. Noise levels (in dBA were measured by means of a sound level meter. Data was collected using a demographic questionnaire and physical examination. Blood pressure was measured by a sphygmomanometer at workplace. The collected data was analyzed by t-tests.    RESULTS: The workers aged 31.5 ± 5.2 years and were exposed to mean noise level of 97.5 ± 10.1 dBA which was significantly above the standard level (85 dBA.The relationships between blood pressure, heart rate, and noise level were not significant. However, Pearson’s correlation indicated systolic blood pressure to have significant correlations with age (correlation coefficient = 0.302 and work experience (correlation coefficient = 0.299.    CONCLUSION: Workers exposed to noise levels above the standard, especially in the metal industry but their blood pressures haven’t any associated with noise. it mention that any changes in blood pressure resulting from occupational noise are likely to be small, careful controls, large sample sizes, and long time exposure to noise would be take to identify significant effects.       Keywords: Noise Exposure, Blood Pressure, Young Workers, Cardiovascular Disease, Metal Industries

  5. Age- and Functional Status-Dependent Association Between Blood Pressure and Cognition

    DEFF Research Database (Denmark)

    Ogliari, Giulia; Sabayan, Behnam; Mari, Daniela

    2015-01-01

    OBJECTIVES: To evaluate whether the relationship between blood pressure (BP) measures and cognitive function is different according to age and functional status in older outpatients. DESIGN: Cross-sectional. SETTING: Outpatient hospital-based Milan Geriatrics 75+ Cohort Study. PARTICIPANTS......: Individuals aged 75 and older (N = 1,540). MEASUREMENTS: Blood pressure, Mini-Mental State Examination (MMSE), basic activities of daily living (ADLs), and instrumental activities of daily living (IADLs) were assessed. Associations between BP measures and MMSE score were first analyzed in the total population...... using linear regression models and were then further examined according to strata of age, ADLs, and IADLs. All analyses were adjusted for sociodemographic factors and presence of comorbidities. RESULTS: In the total population, higher systolic BP (SBP), diastolic BP (DBP), pulse pressure (PP), and mean...

  6. Interarm difference in blood pressure

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels

    2014-01-01

    The present study aimed at examining the interarm difference in blood pressure and its use as an indicator of peripheral arterial disease (PAD). Data were included from consecutive patients referred from their general practitioner to our vascular laboratory for possible PAD aged 50 years or older...... without known cardiac disease, renal disease, or diabetes mellitus. 824 patients (453 women) with mean age of 72 years (range: 50-101) were included. 491 patients had a diagnosis of hypertension and peripheral arterial disease (PAD) was present in 386 patients. Systolic blood pressure was 143 ± 24 mm......Hg and 142 ± 24 mmHg on the right and left arm, respectively (P = 0.015). The interarm difference was greater in patients with hypertension (P = 0.002) and PAD (P blood pressure was reproducible...

  7. Noninvasive estimation of pulmonary arterial pressure by analysis of pulmonary blood-flow distribution

    International Nuclear Information System (INIS)

    Konstam, M.A.; Strauss, H.W.; Alpert, N.M.; Miller, S.W.; Murphy, R.X.; Greene, R.E.; McKusick, K.A.

    1979-01-01

    To determine whether a correlation exists between pulmonary arterial (PA) pressure (P/sub a/) and the distribution of pulmonary blood flow, this distribution was measured in four upright dogs in the control state and during intravenous infusions of epinephrine or prostaglandin F/sub 2α/. During suspension of respiration, 15 mCi of Xe-133 were injected intravenously, and perfusion and equilibration lung images were recorded with a scintillation camera. The procedure was performed several times on each dog, with and without pharmacological elevation of PA pressure by 5 to 50 cm H 2 O. For each scintigram, the relative blood flow per unit ventilated lung volume (F) was plotted against centimeters above the hilum (h). Pulmonary arterial pressure was derived from each curve, assuming the relation F = B(P/sub a/ - hD) 2 , where B = constant and D = specific gravity of blood. Calculated PA pressure correlated strongly (r = 0.83) with measured PA pressure, suggesting a possible means of noninvasive estimation of PA pressure

  8. Risk Stratification by Ambulatory Blood Pressure Monitoring Across JNC Classes of Conventional Blood Pressure

    DEFF Research Database (Denmark)

    Brguljan-Hitij, Jana; Thijs, Lutgarde; Li, Yan

    2014-01-01

    BACKGROUND: Guidelines propose classification of conventional blood pressure (CBP) into normotension (<120/<80 mm Hg), prehypertension (120-139/80-89 mm Hg), and hypertension (≥140/≥90 mm Hg). METHODS: To assess the potential differential contribution of ambulatory blood pressure (ABP) in predict......BACKGROUND: Guidelines propose classification of conventional blood pressure (CBP) into normotension (ABP......%) and of cardiovascular (-34%), cardiac (-33%), or cerebrovascular (-47%) events. Multivariable-adjusted hazard ratios (HRs) for stroke associated with 24-hour and daytime diastolic ABP (+5 mm Hg) were higher (P ≤ 0.045) in normotension than in prehypertension and hypertension (1.98 vs.1.19 vs.1.28 and 1.73 vs.1.09 vs. 1.......24, respectively) with similar trends (0.03 ≤ P ≤ 0.11) for systolic ABP (+10 mm Hg). However, HRs for fatal endpoints and cardiac events associated with ABP did not differ significantly (P ≥ 0.13) across CBP categories. Of normotensive and prehypertensive participants, 7.5% and 29.3% had masked hypertension...

  9. Hypertension Canada's 2016 Canadian Hypertension Education Program Guidelines for Blood Pressure Measurement, Diagnosis, Assessment of Risk, Prevention, and Treatment of Hypertension.

    Science.gov (United States)

    Leung, Alexander A; Nerenberg, Kara; Daskalopoulou, Stella S; McBrien, Kerry; Zarnke, Kelly B; Dasgupta, Kaberi; Cloutier, Lyne; Gelfer, Mark; Lamarre-Cliche, Maxime; Milot, Alain; Bolli, Peter; Tremblay, Guy; McLean, Donna; Tobe, Sheldon W; Ruzicka, Marcel; Burns, Kevin D; Vallée, Michel; Prasad, G V Ramesh; Lebel, Marcel; Feldman, Ross D; Selby, Peter; Pipe, Andrew; Schiffrin, Ernesto L; McFarlane, Philip A; Oh, Paul; Hegele, Robert A; Khara, Milan; Wilson, Thomas W; Penner, S Brian; Burgess, Ellen; Herman, Robert J; Bacon, Simon L; Rabkin, Simon W; Gilbert, Richard E; Campbell, Tavis S; Grover, Steven; Honos, George; Lindsay, Patrice; Hill, Michael D; Coutts, Shelagh B; Gubitz, Gord; Campbell, Norman R C; Moe, Gordon W; Howlett, Jonathan G; Boulanger, Jean-Martin; Prebtani, Ally; Larochelle, Pierre; Leiter, Lawrence A; Jones, Charlotte; Ogilvie, Richard I; Woo, Vincent; Kaczorowski, Janusz; Trudeau, Luc; Petrella, Robert J; Hiremath, Swapnil; Drouin, Denis; Lavoie, Kim L; Hamet, Pavel; Fodor, George; Grégoire, Jean C; Lewanczuk, Richard; Dresser, George K; Sharma, Mukul; Reid, Debra; Lear, Scott A; Moullec, Gregory; Gupta, Milan; Magee, Laura A; Logan, Alexander G; Harris, Kevin C; Dionne, Janis; Fournier, Anne; Benoit, Geneviève; Feber, Janusz; Poirier, Luc; Padwal, Raj S; Rabi, Doreen M

    2016-05-01

    Hypertension Canada's Canadian Hypertension Education Program Guidelines Task Force provides annually updated, evidence-based recommendations to guide the diagnosis, assessment, prevention, and treatment of hypertension. This year, we present 4 new recommendations, as well as revisions to 2 previous recommendations. In the diagnosis and assessment of hypertension, automated office blood pressure, taken without patient-health provider interaction, is now recommended as the preferred method of measuring in-office blood pressure. Also, although a serum lipid panel remains part of the routine laboratory testing for patients with hypertension, fasting and nonfasting collections are now considered acceptable. For individuals with secondary hypertension arising from primary hyperaldosteronism, adrenal vein sampling is recommended for those who are candidates for potential adrenalectomy. With respect to the treatment of hypertension, a new recommendation that has been added is for increasing dietary potassium to reduce blood pressure in those who are not at high risk for hyperkalemia. Furthermore, in selected high-risk patients, intensive blood pressure reduction to a target systolic blood pressure ≤ 120 mm Hg should be considered to decrease the risk of cardiovascular events. Finally, in hypertensive individuals with uncomplicated, stable angina pectoris, either a β-blocker or calcium channel blocker may be considered for initial therapy. The specific evidence and rationale underlying each of these recommendations are discussed. Hypertension Canada's Canadian Hypertension Education Program Guidelines Task Force will continue to provide annual updates. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  10. Reliability of blood pressure parameters for dry weight estimation in hemodialysis patients.

    Science.gov (United States)

    Susantitaphong, Paweena; Laowaloet, Suthanit; Tiranathanagul, Khajohn; Chulakadabba, Adhisabandh; Katavetin, Pisut; Praditpornsilpa, Kearkiat; Tungsanga, Kriang; Eiam-Ong, Somchai

    2013-02-01

    Chronic volume overload resulting from interdialytic weight gain and inadequate fluid removal plays a significant role in poorly controlled high blood pressure. Although bioimpedance has been introduced as an accurate method for assessing hydration status, the instrument is not available in general hemodialysis (HEMO) centers. This study was conducted to explore the correlation between hydration status measured by bioimpedance and blood pressure parameters in chronic HEMO patients. Multifrequency bioimpedance analysis was used to determine pre- and post-dialysis hydration status in 32 stable HEMO patients. Extracellular water/total body water (ECW/TBW) determined by sum of segments from bioimpedance analysis was used as an index of hydration status. The mean age was 57.9 ± 16.4 years. The mean dry weight and body mass index were 57.7 ± 14.5 kg and 22.3 ± 4.7 kg/m(2), respectively. Pre-dialysis ECW/TBW was significantly correlated with only pulse pressure (r = 0.5, P = 0.003) whereas post-dialysis ECW/TBW had significant correlations with pulse pressure, systolic blood pressure, and diastolic blood pressure (r = 0.6, P = 0.001, r = 0.4, P = 0.04, r = -0.4, and P = 0.02, respectively). After dialysis, the mean values of ECW/TBW, systolic blood pressure, mean arterial pressure, and pulse pressure were significantly decreased. ECW/TBW was used to classify the patients into normohydration (≤ 0.4) and overhydration (>0.4) groups. Systolic blood pressure, mean arterial pressure, and pulse pressure significantly reduced after dialysis in the normohydration group but did not significantly change in the overhydration group. Pre-dialysis pulse pressure, post-dialysis pulse pressure, and post-dialysis systolic blood pressure in the overhydration group were significantly higher than normohydration group. Due to the simplicity and cost, blood pressure parameters, especially pulse pressure, might be a simple reference for clinicians to determine hydration status in HEMO

  11. Self-monitoring of blood pressure during pregnancy

    DEFF Research Database (Denmark)

    Lihme, Frederikke F; Madsen, Mette E; Lykke, Jacob A

    2017-01-01

    arterial blood pressure (MAP) and were compared using the paired sample t-test. Mean values and differences of systolic and diastolic pressure were plotted in Bland-Altman plots to test the agreement of the measurements. Finally, a mean evaluation score was calculated. RESULTS: One hundred pregnant women...... and instructed each participant in correct measurement and then took three measurements on both arms. The participant then repeated the measurements and filled an evaluation questionnaire. We used a validated semiautomatic device for all measurements. Mean values were calculated for systolic, diastolic and mean...... were included in the study. Mean values of systolic, diastolic and MAP were 110.6, 69.7 and 83.3 mmHg, respectively, as assessed by the hospital staff. The corresponding self-measurements were 111.4, 70.2 and 83.9 mmHg, respectively. Mean differences between hospital and self-measurements were 0.79 mm...

  12. Postaerobic Exercise Blood Pressure Reduction in Very Old Persons With Hypertension.

    Science.gov (United States)

    Oliveira, Joana; Mesquita-Bastos, José; Argel de Melo, Cristina; Ribeiro, Fernando

    2016-01-01

    A single bout of aerobic exercise acutely decreases blood pressure, even in older adults with hypertension. Nonetheless, blood pressure responses to aerobic exercise in very old adults with hypertension have not yet been documented. Therefore, this study aimed to assess the effect of a single session of aerobic exercise on postexercise blood pressure in very old adults with hypertension. Eighteen older adults with essential hypertension were randomized into exercise (N = 9, age: 83.4 ± 3.2 years old) or control (N = 9, age: 82.7 ± 2.5 years old) groups. The exercise group performed a session of aerobic exercise constituting 2 periods of 10 minutes of walking at an intensity of 40% to 60% of the heart rate reserve. The control group rested for the same period of time. Anthropometric variables and medication status were evaluated at baseline. Heart rate and systolic and diastolic blood pressures were measured at baseline, after exercise, and at 20 and 40 minutes postexercise. Systolic blood pressure showed a significant interaction for group × time (F3,24 = 6.698; P = .002; ηp(2) = 0.153). In the exercise group, the systolic blood pressure at 20 (127.3 ± 20.9 mm Hg) and 40 minutes (123.7 ± 21.0 mm Hg) postexercise was significantly lower in comparison with baseline (135.6 ± 20.6 mm Hg). Diastolic blood pressure did not change. Heart rate was significantly higher after the exercise session. In the control group, no significant differences were observed. A single session of aerobic exercise acutely reduces blood pressure in very old adults with hypertension and may be considered an important nonpharmacological strategy to control hypertension in this age group.

  13. Blood in the gastric lumen increases splanchnic blood flow and portal pressure in portal-hypertensive rats.

    Science.gov (United States)

    Chen, L; Groszmann, R J

    1996-10-01

    In portal-hypertensive humans, portal blood flow and pressure increase after a meal. These hemodynamic changes may increase variceal rupture risk. The aim of this study was to determine whether blood in the stomach lumen increases splanchnic flow and portal pressure (PP) in portal-hypertensive rats. superior mesenteric artery flow and PP were measured in conscious, unrestrained, fasted partial portal vein-ligated rats with chronically implanted Doppler flow probes or portal vein catheters before and after gavage with heparinized, warmed blood from donor rats, air, standard meal, or empty tube. Percentage of changes in flow and pressure from baseline were significantly greater after gavage with blood (an increase of 22.6% +/- 3.5% and an increase of 16.4% +/- 3.1%, respectively) than empty tube (an increase of 3.4% +/- 0.6% and a decrease of 5.4% +/- 3.5%, respectively) (P empty tube (P calories probably contributes to these hemodynamic changes. In patients with variceal hemorrhage, blood in the stomach may increase the risk of persistent variceal bleeding or rebleeding.

  14. Blood pressure response to low level static contractions

    DEFF Research Database (Denmark)

    Fallentin, Nils; Jørgensen, Kurt

    1992-01-01

    The present study re-examines the 15% MVC concept, i.e. the existence of a circulatory steady-state in low intensity static contractions below 15% of maximal voluntary contraction (MVC). Mean arterial blood pressure was studied during static endurance contractions of the elbow flexor and extensor...... 0.7) min for elbow extension]. Mean arterial blood pressure exhibited a continuous and progressive increase during the 10% MVC contractions indicating that the 15% MVC concept would not appear to be valid. The terminal blood pressure value recorded at the point of exhaustion in the 10% MVC elbow...... the circulation to the muscles was arrested just prior to the cessation of the contraction, blood pressure only partly recovered and remained elevated for as long as the occlusion persisted, indicating the level of pressure-raising muscle chemoreflexes. Based on blood pressure recordings obtained during...

  15. High blood pressure in older subjects with cognitive impairment.

    Science.gov (United States)

    Mossello, Enrico; Simoni, David

    2016-06-22

    High blood pressure and cognitive impairment often coexist in old age, but their pathophysiological association is complex. Several longitudinal studies have shown that high blood pressure at midlife is a risk factor for cognitive impairment and dementia, although this association is much less clear in old age. The effect of blood pressure lowering in reducing the risk of dementia is only borderline significant in clinical trials of older subjects, partly due to the insufficient follow-up time. Conversely, dementia onset is associated with a decrease of blood pressure values, probably secondary to neurodegeneration. Prognostic effect of blood pressure values in cognitively impaired older subjects is still unclear, with aggressive blood pressure lowering being potentially harmful in this patients category. Brief cognitive screening, coupled with simple motor assessment, are warranted to identify frail older subjects who need a more cautious approach to antihypertensive treatment. Values obtained with ambulatory blood pressure monitoring seem more useful than clinical ones to predict the outcome of cognitively impaired older subjects. Future studies should identify the most appropriate blood pressure targets in older subjects with cognitive impairment.

  16. The effect of orthostatic stress on multiscale entropy of heart rate and blood pressure

    International Nuclear Information System (INIS)

    Turianikova, Zuzana; Javorka, Kamil; Calkovska, Andrea; Javorka, Michal; Baumert, Mathias

    2011-01-01

    Cardiovascular control acts over multiple time scales, which introduces a significant amount of complexity to heart rate and blood pressure time series. Multiscale entropy (MSE) analysis has been developed to quantify the complexity of a time series over multiple time scales. In previous studies, MSE analyses identified impaired cardiovascular control and increased cardiovascular risk in various pathological conditions. Despite the increasing acceptance of the MSE technique in clinical research, information underpinning the involvement of the autonomic nervous system in the MSE of heart rate and blood pressure is lacking. The objective of this study is to investigate the effect of orthostatic challenge on the MSE of heart rate and blood pressure variability (HRV, BPV) and the correlation between MSE (complexity measures) and traditional linear (time and frequency domain) measures. MSE analysis of HRV and BPV was performed in 28 healthy young subjects on 1000 consecutive heart beats in the supine and standing positions. Sample entropy values were assessed on scales of 1–10. We found that MSE of heart rate and blood pressure signals is sensitive to changes in autonomic balance caused by postural change from the supine to the standing position. The effect of orthostatic challenge on heart rate and blood pressure complexity depended on the time scale under investigation. Entropy values did not correlate with the mean values of heart rate and blood pressure and showed only weak correlations with linear HRV and BPV measures. In conclusion, the MSE analysis of heart rate and blood pressure provides a sensitive tool to detect changes in autonomic balance as induced by postural change

  17. Non-invasive estimation of blood pressure using ultrasound contrast agents

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup; Jensen, Jørgen Arendt

    2009-01-01

    Local blood pressure measurements provide important information on the state of health of organs in the body and can be used to diagnose diseases in the heart, lungs, and kidneys. This paper presents an experimental setup for investigating the ambient pressure sensitivity of a contrast agent using...

  18. Cuff size influences blood pressure measurement in obese children and adolescents

    DEFF Research Database (Denmark)

    Muhamed, P. K.; Olsen, M. H.; Holm, Jens-Christian

    2016-01-01

    Introduction: Recently, we established that a group ofobese children and adolescents had a higher blood pressure(BP) than a healthy control group. In the present study, weinvestigate whether the higher BP in the obese group wasinfluenced by BP cuff sizes.Methods: A total of 104 obese patients aged...... sizes had a significant impact on BP measurements.Despite the influence of cuff size, multiple regressionanalyses revealed that systolic BP was 68 mmHg higherand diastolic BP 32 mmHg higher in the obese groupthan in the control group. A step function, i.e. a sudden fallin BP, was seen at the point...... of switching from small to mediumcuff size in the control group, which suggests that systolicBP was overestimated when using small cuff size andunderestimated when using medium cuff size in subjectswith an AC near 23 cm.Conclusions: BP was higher in the obese group than inthe control group although BP...

  19. Waist-to-Height Ratio as an Indicator of High Blood Pressure in Urban Indian School Children.

    Science.gov (United States)

    Mishra, P E; Shastri, L; Thomas, T; Duggan, C; Bosch, R; McDonald, C M; Kurpad, A V; Kuriyan, R

    2015-09-01

    To examine the utility of waist-to-height ratio to identify risk of high blood pressure when compared to body mass index and waist circumference in South Indian urban school children. Secondary data analysis from a cross-sectional study. Urban schools around Bangalore, India. 1913 children (58.1% males) aged 6-16 years with no prior history of chronic illness (PEACH study). Height, weight, waist circumference and of blood pressure were measured. Children with blood pressure ?90th percentile of age-, sex-, and height-adjusted standards were labelled as having high blood pressure. 13.9% had a high waist-to-height ratio, 15.1% were overweight /obese and 21.7% had high waist circumference. High obesity indicators were associated with an increased risk of high blood pressure. The adjusted risk ratios (95% CI) of high systolic blood pressure with waist-to-height ratio, body mass index and waist circumference were 2.48 (1.76, 3.47), 2.59 (1.66, 4.04) and 2.38 (1.74, 3.26), respectively. Similar results were seen with high diastolic blood pressure. Obesity indicators, especially waist-to-height ratio due to its ease of measurement, can be useful initial screening tools for risk of high blood pressure in urban Indian school children.

  20. Serum leptin levels correlation with high blood pressure in adult females

    International Nuclear Information System (INIS)

    Haque, Z.; Shahid, K.U.; Mazahir, I.; Lakho, G.R.; Nafees, M.

    2006-01-01

    To measure serum leptin levels and compare them in lean and obese subjects and to identify correlation between serum leptin levels, heart rate and hypertension in lean and obese subjects among adult females. Seventy female subjects with different body mass indices were selected from OPD of Jinnah Medical and Dental College Hospital (OPD), Karachi. Heart rate was counted manually; blood pressure was measured by mercury sphygmomanometer while serum leptin was measured using enzyme-linked immunoassay. The outcomes hypertension and heart rate were correlated to risk factor leptin. Mean heart rate, systolic and diastolic blood pressure and serum leptin levels of obese people were 90+-1, 142+-2, 89+-1 and 24.13+-1.7 respectively, which were significantly higher as compared to lean subjects (p<0.05). All the parameters correlated positively and significantly with increasing BMI. There was a relationship of tachycardia and hypertension with high serum leptin levels in obesity. Serum leptin levels increase with the level of obesity. Hyper-leptinemia is associated with tachycardia and increases in both systolic and diastolic blood pressure in obesity via complex mechanisms. (author)

  1. Effect of partial sports massage on blood pressure and heart rate

    Directory of Open Access Journals (Sweden)

    T.D. Pystupa

    2013-12-01

    Full Text Available With the growing popularity and demand for different types of massages (including sports is a growing need for research on specific forms. There is also a need to study the advantages and effects on various body functions. The objective was to study the effect of partial sports massage on blood pressure and heart rate in both men and women. Material and methods. Research has been extended 80 healthy men and women are physically active (age 20-25 years. Blood pressure and heart rate were made on the left arm automatic digital device (model HEM - 907. The device is intended to measure blood pressure. It is established that it is possible to verify the existing beliefs. This promotes more efficient use of massage therapy. Conclusions . Sports massage has an effect on hemodynamic changes, the increase (decrease in blood pressure acceleration (deceleration of the heart rate. It depends on what part of the body exposed to the massage procedure.

  2. Comparison of Doppler and oscillometric ankle blood pressure measurement in patients with angiographically documented lower extremity arterial occlusive disease.

    Science.gov (United States)

    Nukumizu, Yoshihito; Matsushita, Masahiro; Sakurai, Tsunehisa; Kobayashi, Masayoshi; Nishikimi, Naomichi; Komori, Kimihiro

    2007-01-01

    To assess the reliability of the oscillometric method in patients with peripheral vascular disease, ankle blood pressure measurement by Doppler and oscillometry was compared. This study represents a prospective, non-blinded examination of pressure measurements in 168 patients. Twenty-two patients were included who had abdominal aortic aneurysms (AAA) and 146 had peripheral arterial occlusive disease (PAOD). Patients with PAOD were divided into 2 groups according to angiography results: a crural artery occlusion group (CAO, n = 32), and a no crural artery occlusion group (NCAO, n = 114). All subjects underwent pressure measurement by both Doppler and oscillometry. The correlation coefficient was 0.928 in AAA patients and 0.922 in PAOD patients. In CAO patients, there were significantly fewer patients whose oscillometric pressure was equivalent to the Doppler pressure (DP), as compared to NCAO patients, because the oscillometric pressure (OP) was 10% higher than DP in 44% of CAO patients. A high correlation exists between Doppler and oscillometric ankle pressure measurements irrespective of the type of vascular disease. However, the oscillometric method could not be substituted for the Doppler method completely, because there were several patients whose OP was greater than DP especially in those with crural artery occlusive disease.

  3. Chronobiometric assessment of autogenic training effects upon blood pressure and heart rate.

    Science.gov (United States)

    Watanabe, Y; Halberg, F; Cornélissen, G; Saito, Y; Fukuda, K; Otsuka, K; Kikuchi, T

    1996-12-01

    Autogenic training, a method of self-hypnosis, lowers the extent of within-day variation of systolic blood pressure assessed by the circadian double amplitude. The blood pressure and heart rate of ten patients, conventionally diagnosed as having hypertension or white-coat hypertension, were automatically monitored at 30-min intervals for 7 days before autogenic training and again for 7 days, at 1 or 2 months after the start of autogenic training (practiced three times daily). The circadian double amplitude of systolic blood pressure of the patients investigated was 3 to 17 mm Hg lower on autogenic training. In 5 patients, reductions by 7 to 17 mm Hg were statistically significant. These results are regarded as provisional statistics, the utility of which depends on replication. By contrast, the over-all group reduction of the circadian double amplitude of systolic blood pressure by 8 mm Hg on the average can be taken at face value. Autogenic training also lowered the circadian double amplitude of diastolic blood pressure, but the effect was small as was the effect of autogenic training upon the MESOR (a rhythm adjusted mean) and acrophase (a measure of the timing of over-all high values recurring each day). The effect of autogenic training upon the circadian double amplitude of systolic blood pressure suggests its trial as first-line treatment of patients with an excessive circadian blood pressure amplitude, a condition which, even in the absence of an elevated 24-hr, average of blood pressure, is associated with a large increase in the risk of developing ischemic stroke or nephropathy.

  4. Blood pressure among rural Montenegrin children in relation to poverty and gender.

    Science.gov (United States)

    Martinovic, Milica; Belojevic, Goran; Evans, Gary W; Asanin, Bogdan; Lausevic, Dragan; Kovacevic, Natasa Duborija; Samardzic, Mira; Jaksic, Marina; Pantovic, Snezana

    2014-06-01

    Health inequalities may begin during childhood. The aim of this study was to investigate the main effect of poverty and its interactive effect with gender on children's blood pressure. The study was performed in two elementary schools from a rural region near Podgorica, the capital of Montenegro. A questionnaire including questions on family monthly income, children's physical activity and the consumption of junk food was self-administered by parents of 434 children (223 boys and 211 girls) aged 6-13 years. Children's poverty level was assessed using the recommendations from the National Study on Poverty in Montenegro. Children's body weight and height were measured and body mass index-for-gender-and-age percentile was calculated. An oscillometric monitor was used for measurement of children's resting blood pressure in school. A two-factorial analysis of variance with body mass index percentile, physical activity and junk food as covariates showed an interaction of gender and poverty on children's blood pressure, pointing to synergy between poverty and female gender, with statistical significance for raised diastolic pressure (F = 5.462; P = 0.021). Neither physical activity nor the consumption of junk food explained the interactive effect of poverty and gender on blood pressure. We show that poverty is linked to elevated blood pressure for girls but not boys, and this effect is statistically significant for diastolic pressure. The results are discussed in the light of gender differences in stress and coping that are endemic to poverty. © The Author 2013. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  5. Cross-Sectional and longitudinal associations of objectively-measured physical activity on blood pressure: evaluation in 37 countries

    Directory of Open Access Journals (Sweden)

    Mehdi Menai

    2017-09-01

    Full Text Available Background: We examined the cross-sectional and longitudinal associations of objectively measured physical activity (step counts and blood pressure (BP among adults spanning 37countries.Methods: Across 37 countries, we used data from a pool of 9238 adult owners of Withings’ Pulse activity trackers, which measures steps taken each day, and Wireless Blood Pressure Monitor, which measures BP. Analyses were adjusted on age, sex, number of days where the tracker was worn, and number of BP measurements. Data was collected from 2009 to 2013.Results: Subjects had a mean ± standard deviation (SD age of 51.6 ± 11.3 years and a body mass index (BMI of 28.7±5.5 kg/m2. A 1-month increase of more than 3000 steps per day was associated with a decrease of systolic BP (SBP and diastolic BP (DBP among the obese (1.57mm Hg and 1.29 mm Hg respectively, both P<0.001 and the overweight population (0.79mm Hg and 0.84 mm Hg respectively, both P≤0.001, but not in the normal weight population(P=0.60 and P=0.36 respectively.Conclusion: One-month increases in daily step counts was associated with a decrease of SBP and DBP in a large obese and overweight free living population.

  6. Association between different measurements of blood pressure variability by ABP monitoring and ankle-brachial index

    Directory of Open Access Journals (Sweden)

    Moreira Leila B

    2010-11-01

    Full Text Available Abstract Background Blood pressure (BP variability has been associated with cardiovascular outcomes, but there is no consensus about the more effective method to measure it by ambulatory blood pressure monitoring (ABPM. We evaluated the association between three different methods to estimate BP variability by ABPM and the ankle brachial index (ABI. Methods and Results In a cross-sectional study of patients with hypertension, BP variability was estimated by the time rate index (the first derivative of SBP over time, standard deviation (SD of 24-hour SBP; and coefficient of variability of 24-hour SBP. ABI was measured with a doppler probe. The sample included 425 patients with a mean age of 57 ± 12 years, being 69.2% women, 26.1% current smokers and 22.1% diabetics. Abnormal ABI (≤ 0.90 or ≥ 1.40 was present in 58 patients. The time rate index was 0.516 ± 0.146 mmHg/min in patients with abnormal ABI versus 0.476 ± 0.124 mmHg/min in patients with normal ABI (P = 0.007. In a logistic regression model the time rate index was associated with ABI, regardless of age (OR = 6.9, 95% CI = 1.1- 42.1; P = 0.04. In a multiple linear regression model, adjusting for age, SBP and diabetes, the time rate index was strongly associated with ABI (P Conclusion Time rate index is a sensible method to measure BP variability by ABPM. Its performance for risk stratification of patients with hypertension should be explored in longitudinal studies.

  7. Selective serotonin reuptake inhibitors and intraoperative blood pressure.

    Science.gov (United States)

    van Haelst, Ingrid M M; van Klei, Wilton A; Doodeman, Hieronymus J; Kalkman, Cor J; Egberts, Toine C G

    2012-02-01

    The influence of selective serotonin reuptake inhibitors (SSRIs) on blood pressure is poorly understood. We hypothesized that if SSRIs have an influence on blood pressure, this might become manifest in changes in intraoperative blood pressure. We aimed to study the association between perioperative use of SSRIs and changes in intraoperative blood pressure by measuring the occurrence of intraoperative hyper- and hypotension. We conducted a retrospective observational follow-up study among patients who underwent elective primary total hip arthroplasty. The index group included users of SSRIs. The reference group included a random sample (ratio 1:3) of nonusers of an antidepressant agent. The outcome was the occurrence of intraoperative hypo- and hypertensive episodes (number, mean and total duration, and area under the curve (AUC)). The outcome was adjusted for confounding factors using regression techniques. The index group included 20 users of an SSRI. The reference group included 60 nonusers. Users of SSRIs showed fewer intraoperative hypotensive episodes, a shorter mean and total duration, and a smaller AUC when compared to the reference group. After adjustment for confounders, SSRI use was associated with a significantly shorter total duration of hypotension: mean difference of -29.4 min (95% confidence interval (CI) -50.4 to -8.3). Two users of an SSRI and two patients in the reference group had a hypertensive episode. Continuation of treatment with SSRIs before surgery was associated with a briefer duration of intraoperative hypotension.

  8. 24-h blood pressure in Space: The dark side of being an astronaut

    NARCIS (Netherlands)

    Karemaker, John M.; Berecki-Gisolf, Janneke

    2009-01-01

    Inflight 24-h profiles of blood pressure (BP) and heart rate (HR) were recorded in 2 ESA-astronauts by automatic upper arm cuff measurements. In one astronaut this was combined with Portapres (TM) continuous finger blood pressure recordings. It was the intention to contrast the latter to 24-h

  9. Traffic-related air pollution and noise and children's blood pressure: results from the PIAMA birth cohort study.

    Science.gov (United States)

    Bilenko, Natalya; van Rossem, Lenie; Brunekreef, Bert; Beelen, Rob; Eeftens, Marloes; Hoek, Gerard; Houthuijs, Danny; de Jongste, Johan C; van Kempen, Elise; Koppelman, Gerard H; Meliefste, Kees; Oldenwening, Marieke; Smit, Henriette A; Wijga, Alet H; Gehring, Ulrike

    2015-01-01

    Elevation of a child's blood pressure may cause possible health risks in later life. There is evidence for adverse effects of exposure to air pollution and noise on blood pressure in adults. Little is known about these associations in children. We investigated the associations of air pollution and noise exposure with blood pressure in 12-year-olds. Blood pressure was measured at age 12 years in 1432 participants of the PIAMA birth cohort study. Annual average exposure to traffic-related air pollution [NO2, mass concentrations of particulate matter with diameters of less than 2.5 µm (PM2.5) and less than 10 µm (PM10), and PM2.5 absorbance] at the participants' home and school addresses at the time of blood pressure measurements was estimated by land-use regression models. Air pollution exposure on the days preceding blood pressure measurements was estimated from routine air monitoring data. Long-term noise exposure was assessed by linking addresses to modelled equivalent road traffic noise levels. Associations of exposures with blood pressure were analysed by linear regression. Effects are presented for an interquartile range increase in exposure. Long-term exposure to NO2 and PM2.5 absorbance were associated with increased diastolic blood pressure, in children who lived at the same address since birth [adjusted mean difference (95% confidence interval) [mmHg] 0.83 (0.06 to 1.61) and 0.75 (-0.08 to 1.58), respectively], but not with systolic blood pressure. We found no association of blood pressure with short-term air pollution or noise exposure. Long-term exposure to traffic-related air pollution may increase diastolic blood pressure in children. © The European Society of Cardiology 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  10. Does blood pressure change in treated hypertensive patients depending on whether it is measured by a physician or a nurse?

    Science.gov (United States)

    Coll De Tuero, Gabriel; Sanmartin Albertos, Maria; Vargas Vila, Susanna; Trèmols Iglesias, Susanna; Saez Zafra, Marc; Barceló Rado, Antonia

    2004-01-01

    To determine whether there are differences between blood pressure (BP) measured by the nurse (NBP), BP measured by the physician (PBP) and self-measured BP in treated hypertensive patients and, if found, to evaluate their clinical importance. An observational study is carried out with hypertensive patients recruited from two village-based community health centres in Catalonia (Spain) serving an area with a total population of 2800 inhabitants. All patients treated for hypertension visiting the health centre on a specific day of the week and during the same timetable between October 2000 and May 2001 were included. The difference between physician-systolic BP and nurse-systolic BP was 5.16 mmHg (95% CI 2.62-7.7; pself-measured systolic BP was 4.67 mmHg (95% CI 0.89-8.44; p=0.016). The differences between nurse-systolic BP and self-measured systolic BP were not significant (0.49 mmHg; 95% CI 3.71-2.71; p=0.758). With regards to diastolic BP, no significant differences were found between the different ways of measurement. NBP gave the following values: sensitivity (Sn) of 92% and specificity (Sp) of 60%; positive predictive value (PPV) of 65.7% and negative predictive value (NPV) of 90% with a positive coefficient of probability (CP+) of 2.3 and a negative coefficient of probability (CP-) of 0.133. PBP gave the following results: Sn=72%; Sp=66.7%; PPV=64.3%; NPV=74.1%; CP+=2.16 and CP- = 0.420. Systolic BP measured by the nurse in treated hypertensive patients is significantly lower than the readings obtained by the physician, and are almost identical to ambulatory BP monitoring. Blood pressure determination by the nurse is desirable not only for diagnosis but also to evaluate the level of control of blood pressure during the follow-up of treated hypertensive patients.

  11. Significant role of the cardiopostural interaction in blood pressure regulation during standing.

    Science.gov (United States)

    Xu, Da; Verma, Ajay K; Garg, Amanmeet; Bruner, Michelle; Fazel-Rezai, Reza; Blaber, Andrew P; Tavakolian, Kouhyar

    2017-09-01

    Cardiovascular and postural control systems have been studied independently despite the increasing evidence showing the importance of cardiopostural interaction in blood pressure regulation. In this study, we aimed to assess the role of the cardiopostural interaction in relation to cardiac baroreflex in blood pressure regulation under orthostatic stress before and after mild exercise. Physiological variables representing cardiovascular control (heart rate and systolic blood pressure), lower limb muscle activation (electromyography), and postural sway (center of pressure derived from force and moment data during sway) were measured from 17 healthy participants (25 ± 2 yr, 9 men and 8 women) during a sit-to-stand test before and after submaximal exercise. The cardiopostural control (characterized by baroreflex-mediated muscle-pump effect in response to blood pressure changes, i.e., muscle-pump baroreflex) was assessed using wavelet transform coherence and causality analyses in relation to the baroreflex control of heart rate. Significant cardiopostural blood pressure control was evident counting for almost half of the interaction time with blood pressure changes that observed in the cardiac baroreflex (36.6-72.5% preexercise and 34.7-53.9% postexercise). Thus, cardiopostural input to blood pressure regulation should be considered when investigating orthostatic intolerance. A reduction of both cardiac and muscle-pump baroreflexes in blood pressure regulation was observed postexercise and was likely due to the absence of excessive venous pooling and a less stressed system after mild exercise. With further studies using more effective protocols evoking venous pooling and muscle-pump activity, the cardiopostural interaction could improve our understanding of the autonomic control system and ultimately lead to a more accurate diagnosis of cardiopostural dysfunctions. NEW & NOTEWORTHY We examined the interaction between cardiovascular and postural control systems during

  12. THE EFFECT OF HORMONE THERAPY ON MEAN BLOOD PRESSURE AND VISIT-TO-VISIT BLOOD PRESSURE VARIABILITY IN POSTMENOPAUSAL WOMEN: RESULTS FROM THE WOMEN’S HEALTH INITIATIVE RANDOMIZED CONTROLLED TRIALS

    Science.gov (United States)

    Shimbo, Daichi; Wang, Lu; Lamonte, Michael J.; Allison, Matthew; Wellenius, Gregory A.; Bavry, Anthony A.; Martin, Lisa W.; Aragaki, Aaron; Newman, Jonathan D.; Swica, Yael; Rossouw, Jacques E.; Manson, JoAnn E.; Wassertheil-Smoller, Sylvia

    2014-01-01

    Objectives Mean and visit-to-visit variability (VVV) of blood pressure are associated with an increased cardiovascular disease risk. We examined the effect of hormone therapy on mean and VVV of blood pressure in postmenopausal women from the Women’s Health Initiative (WHI) randomized controlled trials. Methods Blood pressure was measured at baseline and annually in the two WHI hormone therapy trials in which 10,739 and 16,608 postmenopausal women were randomized to conjugated equine estrogens (CEE, 0.625 mg/day) or placebo, and CEE plus medroxyprogesterone acetate (MPA, 2.5 mg/day) or placebo, respectively. Results At the first annual visit (Year 1), mean systolic blood pressure was 1.04 mmHg (95% CI 0.58, 1.50) and 1.35 mmHg (95% CI 0.99, 1.72) higher in the CEE and CEE+MPA arms respectively compared to corresponding placebos. These effects remained stable after Year 1. CEE also increased VVV of systolic blood pressure (ratio of VVV in CEE vs. placebo, 1.03, Pblood pressure increased at Year 1, and the differences in the CEE and CEE+MPA arms vs. placebos also continued to increase after Year 1. Further, both CEE and CEE+MPA significantly increased VVV of systolic blood pressure (ratio of VVV in CEE vs. placebo, 1.04, Pblood pressure. PMID:24991872

  13. Real-time measurement of blood pressure with Nexfin in a patient with thalidomide-related phocomelia.

    Science.gov (United States)

    Earle, Rosie; Vaghadia, Himat; Shanahan, Enda; Tang, Raymond; Sawka, Andrew

    2016-11-01

    We report the novel application of photoplethysmographic technology with the Nexfin HD monitor for real-time measurement of blood pressure (BP) in a patient with tetraamelia. The patient was a 58-year-old man with tetraamelia secondary to thalidomide exposure in utero, who presented for surgical excision of a maxillary schwannoma. Because difficulty of cuff use on rudimentary limbs and failure to gain invasive arterial access due to abnormalities of limb vasculature, this population is known to pose some unique challenges for BP measurement. Nexfin may offer an alternative noninvasive method to detect BP in patients with phocomelia during the perioperative period. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Surgical treatment reduces blood pressure in children with unilateral congenital hydronephrosis.

    Science.gov (United States)

    Al-Mashhadi, Ammar; Nevéus, Tryggve; Stenberg, Arne; Karanikas, Birgitta; Persson, A Erik G; Carlström, Mattias; Wåhlin, Nils

    2015-04-01

    Renal disorders can cause hypertension, but less is known about the influence of hydronephrosis on blood pressure. Hydronephrosis due to pelvo-ureteric junction obstruction (PUJO) is a fairly common condition (incidence in newborns of 0.5-1%). Although hypertensive effects of hydronephrosis have been suggested, this has not been substantiated by prospective studies in humans [1-3]. Experimental studies with PUJO have shown that animals with induced hydronephrosis develop salt-sensitive hypertension, which strongly correlate to the degree of obstruction [4-7]. Moreover, relief of the obstruction normalized blood pressure [8]. In this first prospective study our aim was to study the blood pressure pattern in pediatric patients with hydronephrosis before and after surgical correction of the ureteral obstruction. Specifically, we investigated if preoperative blood pressure is reduced after surgery and if split renal function and renographic excretion curves provide any prognostic information. Twelve patients with unilateral congenital hydronephrosis were included in this prospective study. Ambulatory blood pressure (24 h) was measured preoperatively and six months after surgery. Preoperative evaluations of bilateral renal function by Tc99m-MAG3 scintigraphy, and renography curves, classified according to O'Reilly, were also performed. As shown in the summary figure, postoperative systolic (103 ± 2 mmHg) and diastolic (62 ± 2 mmHg) blood pressure were significantly lower than those obtained preoperatively (110 ± 4 and 69 ± 2 mmHg, respectively), whereas no changes in circadian variation or pulse pressure were observed. Renal functional share of the hydronephrotic kidney ranged from 11 to 55%. There was no correlation between the degree of renal function impairment and the preoperative excretory pattern, or between the preoperative excretory pattern and the blood pressure reduction postoperatively. However, preoperative MAG3 function of the affected kidney correlated

  15. Reference data for distal blood pressure in healthy elderly and middle-aged individuals measured with the strain gauge technique. Part II: Distal blood pressure after exercise

    DEFF Research Database (Denmark)

    Arveschoug, Anne Kirstine; Vammen, Birthe; Yoshinaka, Emmy

    2008-01-01

    collected in the early 1970s from healthy individuals in the age range 21-26 years. Our aims were to collect new reference data for DBP at ankle level after exercise based on older populations, and to compare between reference data for different age groups to find out whether the normal values are dependent......Objective. Distal blood pressure (DBP) determination after an exercise test is used on suspicion of arterial peripheral vascular disease (apvd). In our department. the average age of these patients is about 60 years. The usual reference values for pressures after exercise were based on data...... on age. Material and methods. DBP after exercise was measured using the strain-gauge technique on individuals in two groups: group I comprising 25 healthy persons aged between 61 and 82 years, and group II 14 healthy persons aged between 45 and 58 years. Strict rules of inclusion were followed. Results...

  16. Diagnosis of childhood hypertension: is blood pressure height ratio ...

    African Journals Online (AJOL)

    Blood pressure was also recorded according to the standard method. Systolic and diastolic blood pressure to height ratio were then calculated. Receiver operating curves was used to assess the ability of systolic blood and diastolic blood pressure height ratio to discriminate childhood prehypertension and hypertension.

  17. Inter-arm blood pressure difference in hospitalized elderly patients--is it consistent?

    Science.gov (United States)

    Grossman, Alon; Weiss, Avraham; Beloosesky, Yichayaou; Morag-Koren, Nira; Green, Hefziba; Grossman, Ehud

    2014-07-01

    Inter-arm blood pressure difference (IAD) is recognized as a risk factor for cardiovascular mortality. Its reproducibility in the elderly is unknown. The authors determined the prevalence and reproducibility of IAD in hospitalized elderly patients. Blood pressure was measured simultaneously in both arms on two different days in elderly individuals hospitalized in a geriatric ward. The study included 364 elderly patients (mean age, 85±5 years). Eighty-four patients (23%) had systolic IAD >10 and 62 patients (17%) had diastolic IAD >10 mm Hg. A total of 319 patients had two blood pressure measurements. Systolic and diastolic IAD remained in the same category in 203 (64%) and 231 (72%) patients, respectively. Correlations of systolic and diastolic IAD between the two measurements were poor. Consistency was not affected by age, body mass index, comorbidities, or treatment. IAD is extremely common in hospitalized elderly patients, but, because of poor consistency, its clinical significance in this population is uncertain. ©2014 Wiley Periodicals, Inc.

  18. How to Prevent High Blood Pressure: MedlinePlus Health Topic

    Science.gov (United States)

    ... Spanish Understanding Blood Pressure Readings (American Heart Association) Weightlifting: Bad for Your Blood Pressure? (Mayo Foundation for ... High Blood Pressure High Blood Pressure in Pregnancy Nutrition Quitting Smoking Stress National Institutes of Health The ...

  19. Blood pressure-lowering treatment strategies based on cardiovascular risk versus blood pressure: A meta-analysis of individual participant data.

    Science.gov (United States)

    Karmali, Kunal N; Lloyd-Jones, Donald M; van der Leeuw, Joep; Goff, David C; Yusuf, Salim; Zanchetti, Alberto; Glasziou, Paul; Jackson, Rodney; Woodward, Mark; Rodgers, Anthony; Neal, Bruce C; Berge, Eivind; Teo, Koon; Davis, Barry R; Chalmers, John; Pepine, Carl; Rahimi, Kazem; Sundström, Johan

    2018-03-01

    Clinical practice guidelines have traditionally recommended blood pressure treatment based primarily on blood pressure thresholds. In contrast, using predicted cardiovascular risk has been advocated as a more effective strategy to guide treatment decisions for cardiovascular disease (CVD) prevention. We aimed to compare outcomes from a blood pressure-lowering treatment strategy based on predicted cardiovascular risk with one based on systolic blood pressure (SBP) level. We used individual participant data from the Blood Pressure Lowering Treatment Trialists' Collaboration (BPLTTC) from 1995 to 2013. Trials randomly assigned participants to either blood pressure-lowering drugs versus placebo or more intensive versus less intensive blood pressure-lowering regimens. We estimated 5-y risk of CVD events using a multivariable Weibull model previously developed in this dataset. We compared the two strategies at specific SBP thresholds and across the spectrum of risk and blood pressure levels studied in BPLTTC trials. The primary outcome was number of CVD events avoided per persons treated. We included data from 11 trials (47,872 participants). During a median of 4.0 y of follow-up, 3,566 participants (7.5%) experienced a major cardiovascular event. Areas under the curve comparing the two treatment strategies throughout the range of possible thresholds for CVD risk and SBP demonstrated that, on average, a greater number of CVD events would be avoided for a given number of persons treated with the CVD risk strategy compared with the SBP strategy (area under the curve 0.71 [95% confidence interval (CI) 0.70-0.72] for the CVD risk strategy versus 0.54 [95% CI 0.53-0.55] for the SBP strategy). Compared with treating everyone with SBP ≥ 150 mmHg, a CVD risk strategy would require treatment of 29% (95% CI 26%-31%) fewer persons to prevent the same number of events or would prevent 16% (95% CI 14%-18%) more events for the same number of persons treated. Compared with treating

  20. Blood pressure-lowering treatment strategies based on cardiovascular risk versus blood pressure: A meta-analysis of individual participant data.

    Directory of Open Access Journals (Sweden)

    Kunal N Karmali

    2018-03-01

    Full Text Available Clinical practice guidelines have traditionally recommended blood pressure treatment based primarily on blood pressure thresholds. In contrast, using predicted cardiovascular risk has been advocated as a more effective strategy to guide treatment decisions for cardiovascular disease (CVD prevention. We aimed to compare outcomes from a blood pressure-lowering treatment strategy based on predicted cardiovascular risk with one based on systolic blood pressure (SBP level.We used individual participant data from the Blood Pressure Lowering Treatment Trialists' Collaboration (BPLTTC from 1995 to 2013. Trials randomly assigned participants to either blood pressure-lowering drugs versus placebo or more intensive versus less intensive blood pressure-lowering regimens. We estimated 5-y risk of CVD events using a multivariable Weibull model previously developed in this dataset. We compared the two strategies at specific SBP thresholds and across the spectrum of risk and blood pressure levels studied in BPLTTC trials. The primary outcome was number of CVD events avoided per persons treated. We included data from 11 trials (47,872 participants. During a median of 4.0 y of follow-up, 3,566 participants (7.5% experienced a major cardiovascular event. Areas under the curve comparing the two treatment strategies throughout the range of possible thresholds for CVD risk and SBP demonstrated that, on average, a greater number of CVD events would be avoided for a given number of persons treated with the CVD risk strategy compared with the SBP strategy (area under the curve 0.71 [95% confidence interval (CI 0.70-0.72] for the CVD risk strategy versus 0.54 [95% CI 0.53-0.55] for the SBP strategy. Compared with treating everyone with SBP ≥ 150 mmHg, a CVD risk strategy would require treatment of 29% (95% CI 26%-31% fewer persons to prevent the same number of events or would prevent 16% (95% CI 14%-18% more events for the same number of persons treated. Compared with

  1. Caffeine: How Does It Affect Blood Pressure?

    Science.gov (United States)

    ... naturally increase your blood pressure, such as exercise, weightlifting or hard physical labor. To see if caffeine ... blood pressure and stress indices in healthy individuals. Nutrition Journal. 2016;15:26. Cano-Marquina A, et ...

  2. Ambulatory blood pressure monitoring - comparison with office ...

    African Journals Online (AJOL)

    ambulatory blood pressure recordings in private practice ... position according to established guidelines. ... white-coat effect was defined as a difference of at least 20 .... patients with hypertension: Importance of blood pressure response to ...

  3. Tail-Cuff Technique and Its Influence on Central Blood Pressure in the Mouse.

    Science.gov (United States)

    Wilde, Elena; Aubdool, Aisah A; Thakore, Pratish; Baldissera, Lineu; Alawi, Khadija M; Keeble, Julie; Nandi, Manasi; Brain, Susan D

    2017-06-27

    Reliable measurement of blood pressure in conscious mice is essential in cardiovascular research. Telemetry, the "gold-standard" technique, is invasive and expensive and therefore tail-cuff, a noninvasive alternative, is widely used. However, tail-cuff requires handling and restraint during measurement, which may cause stress affecting blood pressure and undermining reliability of the results. C57Bl/6J mice were implanted with radio-telemetry probes to investigate the effects of the steps of the tail-cuff technique on central blood pressure, heart rate, and temperature. This included comparison of handling techniques, operator's sex, habituation, and influence of hypertension induced by angiotensin II. Direct comparison of measurements obtained by telemetry and tail-cuff were made in the same mouse. The results revealed significant increases in central blood pressure, heart rate, and core body temperature from baseline following handling interventions without significant difference among the different handling technique, habituation, or sex of the investigator. Restraint induced the largest and sustained increase in cardiovascular parameters and temperature. The tail-cuff readings significantly underestimated those from simultaneous telemetry recordings; however, "nonsimultaneous" telemetry, obtained in undisturbed mice, were similar to tail-cuff readings obtained in undisturbed mice on the same day. This study reveals that the tail-cuff technique underestimates the core blood pressure changes that occur simultaneously during the restraint and measurement phases. However, the measurements between the 2 techniques are similar when tail-cuff readings are compared with telemetry readings in the nondisturbed mice. The differences between the simultaneous recordings by the 2 techniques should be recognized by researchers. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  4. Influence of Partial Pressure of Oxygen in Blood Samples on Measurement Performance in Glucose-Oxidase-Based Systems for Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-01-01

    Background Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Methods Aliquots of 20 venous samples were adjusted to the following pO2 values: pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 pO2 pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p pO2 values pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. PMID:24351177

  5. Baseline Blood Pressure, the 2017 ACC/AHA High Blood Pressure Guidelines, and Long-Term Cardiovascular Risk in SPRINT.

    Science.gov (United States)

    Vaduganathan, Muthiah; Pareek, Manan; Qamar, Arman; Pandey, Ambarish; Olsen, Michael H; Bhatt, Deepak L

    2018-02-05

    The 2017 American College of Cardiology (ACC)/American Heart Association (AHA) guidelines include lower thresholds to define hypertension than previous guidelines. Little is known about the impact of these guideline changes in patients with or at high risk for cardiovascular disease. In this exploratory analysis using baseline blood pressure assessments in Systolic Blood Pressure Intervention Trial (SPRINT), we evaluated the prevalence and associated cardiovascular prognosis of patients newly reclassified with hypertension based on the 2017 ACC/AHA (systolic blood pressure ≥130 mm Hg or diastolic blood pressure ≥80 mm Hg) compared with the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation and Treatment of High Blood Pressure (JNC 7) guidelines (systolic blood pressure ≥140 mm Hg or diastolic blood pressure ≥90 mm Hg). The primary endpoint was the composite of myocardial infarction, other acute coronary syndromes, stroke, heart failure, or cardiovascular death. In 4683 patients assigned to the standard treatment arm of SPRINT, 2328 (49.7%) met hypertension thresholds by JNC 7 guidelines, and another 1424 (30.4%) were newly reclassified as having hypertension based on the 2017 ACC/AHA guidelines. Over 3.3-year median follow-up, 319 patients experienced the primary endpoint (87 of whom were newly reclassified with hypertension based on the revised guidelines). Patients with hypertension based on prior guidelines compared with those newly identified with hypertension based on the new guidelines had similar risk of the primary endpoint (2.3 [95% confidence interval {CI}, 2.0-2.7] vs 2.0 [95% CI, 1.6-2.4] events per 100 patient-years; adjusted HR, 1.10 [95% CI, 0.84-1.44]; P = .48). The 2017 ACC/AHA high blood pressure guidelines are expected to significantly increase the prevalence of patients with hypertension (perhaps to a greater extent in higher-risk patient cohorts compared with the general population) and

  6. Racial differences in the impact of social support on nocturnal blood pressure.

    Science.gov (United States)

    Cooper, Denise C; Ziegler, Michael G; Nelesen, Richard A; Dimsdale, Joel E

    2009-06-01

    To investigate whether black and white adults benefit similarly from perceived social support in relation to blood pressure (BP) dipping during sleep. The Interpersonal Support Evaluation List (ISEL, 12-item version), which measures the perceived availability of several types of functional social support, was examined for interactive effects with race on dipping of mean arterial pressure (MAP), systolic blood pressure (SBP), and diastolic blood pressure (DBP) derived from 24-hour ambulatory blood pressure monitoring (ABPM). The sample consisted of 156 young to middle-aged adults (61 blacks, 95 whites; mean age = 35.7 years). Mean ISEL scores did not differ between racial groups. Controlling for age, body mass index (BMI), resting BP, and socioeconomic status (SES), the interaction of social support by race yielded associations with nighttime dipping in MAP and DBP (p social support increased, white adults received cardiovascular benefits as suggested by enhanced nocturnal dipping of BP, but black adults accrued risks as evidenced by blunted declines in BP during sleep.

  7. Relation of urinary calcium and magnesium excretion to blood pressure

    DEFF Research Database (Denmark)

    Kesteloot, Hugo; Tzoulaki, Ioanna; Brown, Ian J

    2011-01-01

    Data indicate an inverse association between dietary calcium and magnesium intakes and blood pressure (BP); however, much less is known about associations between urinary calcium and magnesium excretion and BP in general populations. The authors assessed the relation of BP to 24-hour excretion...... of calcium and magnesium in 2 cross-sectional studies. The International Study of Macro- and Micro-Nutrients and Blood Pressure (INTERMAP) comprised 4,679 persons aged 40-59 years from 17 population samples in China, Japan, the United Kingdom, and the United States, and the International Cooperative Study...... on Salt, Other Factors, and Blood Pressure (INTERSALT) comprised 10,067 persons aged 20-59 years from 52 samples around the world. Timed 24-hour urine collections, BP measurements, and nutrient data from four 24-hour dietary recalls (INTERMAP) were collected. In multiple linear regression analyses...

  8. Stress and High Blood Pressure: What's the Connection?

    Science.gov (United States)

    Stress and high blood pressure: What's the connection? Stress and long-term high blood pressure may not be linked, but taking steps to reduce your stress can improve your general health, including your blood ...

  9. Toe blood pressure and leg muscle oxygenation with body posture.

    Science.gov (United States)

    Rosales-Velderrain, Armando; Cardno, Michael; Mateus, Jaime; Kumar, Ravindra; Schlabs, Thomas; Hargens, Alan R

    2011-05-01

    In 1980 Katkov and Chestukhin measured blood pressures and oxygenation invasively at various body tilt angles at different locations on the body, including the foot. To our knowledge, such measurements have not been performed noninvasively. Therefore, the purpose of this study was to measure toe blood pressure (TBP) and lower limb muscle oxygenation noninvasively at various body tilt angles, and to assess the use of a Finometer for noninvasive TBP measurements. Our noninvasive results are compared with those performed by Katkov and Chestukhin. We hypothesized that: 1) the Finometer provides a noninvasive measurement of TBP at different tilt angles; and 2) muscle oxygenation is highest with 0 and -6 degrees, and decreases with increased head-up tilt (HUT). There were 10 subjects who were exposed to different body tilt angles (-6, 0, 10, 30, 70, and 90 degrees). At each angle we measured TBP noninvasively with a Finometer and muscle tissue oxygenation by near infrared spectroscopy. We found a strong correlation between TBP using the Finometer and TBP predicted by adding the hydrostatic component due to body tilt to the standard arm blood pressure measurement. At 10, 30, 70, and 90 degrees both TBP and tissue oxygenation were significantly different from the 0 degree (supine) level. Oxygenation decreased and TBP increased with higher HUT angles. No differences were observed in TBP or oxygenation between -6 and 0 degree. The Finometer accurately measures TBP noninvasively with body tilt. Also, muscle oxygenation is highest at small HUT angles and decreases with increased HUT.

  10. Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Guo, Wan-Gang; Li, Bing-Ling; He, Yong; Xue, Yu-Sheng; Wang, Hai-Yan; Zheng, Qiang-Sun; Xiang, Ding-Cheng

    2014-08-01

    To validate the Andon KD-5917 automatic upper arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Sequential same-left-arm measurements of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were obtained in 33 participants using the mercury sphygmomanometer and the test device. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained in the study. The device produced 73, 98, and 99 measurements within 5, 10, and 15 mmHg for SBP and 86, 98, and 99 for DBP, respectively. The mean ± SD device-observer difference was 3.07 ± 3.68 mmHg for SBP and -0.89 ± 3.72 mmHg for DBP. The number of patients with two or three of the device-observer difference within 5 mmHg was 26 for SBP and 29 for DBP, and no patient had a device-observer difference within 5 mmHg. The Andon KD-5917 automatic upper arm blood pressure monitor can be recommended for clinical use and self-measurement in an adult population on the basis of the European Society of Hypertension International Protocol revision 2010.

  11. Frequency of diarrhoea as a predictor of elevated blood pressure in children

    Science.gov (United States)

    Miranda, Juan Jaime; Davies, Alisha R.; Smith, George Davey; Smeeth, Liam; Cabrera, Lilia; Gilman, Robert H.; García, Héctor H.; Ortega, Ynes R.; Cama, Vitaliano A.

    2009-01-01

    Background Diarrhoeal illness is a major public health problem for children worldwide, particularly among developing countries, and is a proxy condition for severe dehydration. It has been hypothesized that severe dehydration in the first 6 months of life could be associated with increased blood pressure later in life. This study aimed to explore whether frequency of diarrhoea is associated with elevated blood pressure in children in a setting with a high incidence of diarrhoeal disease. Methods The present study is a cross-sectional study of blood pressure among children from a longitudinal child diarrhoeal disease cohort in Lima, Peru. From 2001 to 2006, daily diarrhoeal surveillance was made. Children were revisited in 2006 and blood pressure was measured. Diarrhoeal exposures were evaluated in terms of total number of diarrhoea days, number of episodes of diarrhoea, persistent diarrhoeal episodes and by the quartiles of daily incidence and episode incidence of diarrhoea. Results The overall incidence of diarrhoeal episodes at age under 1 year was 4.35 (95% confidence interval: 3.79-4.98) and under 5 years was 2.80 (95% confidence interval: 2.69-2.92). No association was observed between the total number of diarrhoeal days, diarrhoeal episodes or diarrhoeal incidence rates with childhood blood pressure. There was weak evidence that hospital admission due to severe dehydration in the first year of life showed a gradient towards an increase in both, systolic and diastolic blood pressure. Conclusion In the first study to date to examine the association in a setting with a high incidence of diarrhoeal disease, diarrhoeal frequency did not show an association with increased blood pressure. Our observations of elevated levels of blood pressure among those admitted into hospitals in the first year of life are in line with the original hypothesis of dehydration in early infancy and high blood pressure. However, the effect of episodes of severe dehydration on later blood

  12. Ambulatory blood pressure and blood lipids in a multiethnic sample of healthy adults.

    Science.gov (United States)

    James, Gary D; Van Berge-Landry, Helene M; Morrison, Lynn A; Reza, Angela M; Nicolaisen, Nicola M; Bindon, James R; Brown, Daniel E

    2013-01-01

    Elevated blood pressure (BP), elevated serum cholesterol, and aberrant lipoprotein fractions (low levels of high-density lipoprotein (HDL) and high levels of low-density lipoprotein fractions and triglycerides) have all been used as measures that assess the "metabolic syndrome" and more recently in indexes of allostatic load, which are designed to assess the degree of integrated metabolic pathology. While there are ample data regarding the interrelationships of these measures in various pathophysiological settings, there are limited data regarding the interrelationship of ambulatory BP (ABP) and blood lipids in healthy subjects. The present study evaluates ABP-blood lipid relationships in a multiethnic sample of healthy adults. The subjects were 37 men (age = 40.9 ± 10.7 years) and 42 women (age = 35.8 ± 10.4 years) who were employed as hotel workers in Hawaii. Each wore an ABP monitor for one midweek workday and had pressures averaged in three daily microenvironments (work, home, and during sleep). They also had fasting blood samples taken for lipid profiling. Multivariate analysis of covariance shows that there was a strong inverse relationship between HDL and both systolic (P act as a group in healthy adults but that higher HDL is associated with lower BP. This latter finding is consistent with research that shows that HDL promotes vasodilation via its effect on endothelial nitric oxide synthase. Copyright © 2013 Wiley Periodicals, Inc.

  13. Calcium Supplements: Do They Interfere with Blood Pressure Drugs?

    Science.gov (United States)

    ... with blood pressure drugs? Is it true that calcium supplements may interact with blood pressure medications? Answers ... G. Sheps, M.D. Yes. In large amounts, calcium supplements may interact with some blood pressure medications. ...

  14. Snapshot: Blood Pressure in the U.S.

    Science.gov (United States)

    ... please visit this page: About CDC.gov . Home Blood Pressure: Make Control Your Goal Infographic Recommend on Facebook ... Compartir Copy the code below to use the Blood Pressure Infographic on your web page or social media ...

  15. Goat Meat Does Not Cause Increased Blood Pressure

    Directory of Open Access Journals (Sweden)

    Katsunori Sunagawa

    2014-01-01

    Full Text Available While there are persistent rumors that the consumption of goat meat dishes increases blood pressure, there is no scientific evidence to support this. Two experiments were conducted to clarify whether or not blood pressure increases in conjunction with the consumption of goat meat dishes. In experiment 1, 24 Dahl/Iwai rats (15 weeks old, body weight 309.3±11.1 g were evenly separated into 4 groups. The control group (CP was fed a diet containing 20% chicken and 0.3% salt on a dry matter basis. The goat meat group (GM was fed a diet containing 20% goat meat and 0.3% salt. The goat meat/salt group (GS was fed a diet containing 20% goat meant and 3% to 4% salt. The Okinawan mugwort (Artemisia Princeps Pampan/salt group (GY was fed a diet containing 20% goat meat, 3% to 4% salt and 5% of freeze-dried mugwort powder. The experiment 1 ran for a period of 14 weeks during which time the blood pressure of the animals was recorded. The GS, and GY groups consumed significantly more water (p<0.01 than the CP and GM groups despite the fact that their diet consumption levels were similar. The body weight of animals in the CP, GM, and GS groups was similar while the animals in the GY group were significantly smaller (p<0.01. The blood pressure in the GM group was virtually the same as the CP group throughout the course of the experiment. In contrast, while the blood pressure of the animals in the GS and GY group from 15 to 19 weeks old was the same as the CP group, their blood pressures were significantly higher (p<0.01 after 20 weeks of age. The GY group tended to have lower blood pressure than the GS group. In experiment 2, in order to clarify whether or not the increase in blood pressure in the GS group and the GY group in experiment 1 was caused by an excessive intake of salt, the effects on blood pressure of a reduction of salt in diet were investigated. When amount of salt in the diet of the GS and GY group was reduced from 4% to 0.3%, the animal

  16. The Impact of Resonance Frequency Breathing on Measures of Heart Rate Variability, Blood Pressure, and Mood

    Directory of Open Access Journals (Sweden)

    Patrick R. Steffen

    2017-08-01

    Full Text Available Heart rate variability biofeedback (HRVB significantly improves heart rate variability (HRV. Breathing at resonance frequency (RF, approximately 6 breaths/min constitutes a key part of HRVB training and is hypothesized to be a pathway through which biofeedback improves HRV. No studies to date, however, have experimentally examined whether RF breathing impacts measures of HRV. The present study addressed this question by comparing three groups: the RF group breathed at their determined RF for 15 min; the RF + 1 group breathed at 1 breath/min higher than their determined RF for 15 min; and the third group sat quietly for 15 min. After this 15-min period, all groups participated in the Paced Auditory Serial Addition Task (PASAT for 8 min, and then sat quietly during a 10-min recovery period. HRV, blood pressure, and mood were measured throughout the experiment. Groups were not significantly different on any of the measures at baseline. After the breathing exercise, the RF group reported higher positive mood than the other two groups and a significantly higher LF/HF HRV ratio relative to the control group, a key goal in HRVB training (p < 0.05. Additionally, the RF group showed lower systolic blood pressure during the PASAT and during the recovery period relative to the control group, with the RF + 1 group not being significantly different from either group (p < 0.05. Overall, RF breathing appears to play an important role in the positive effect HRVB has on measures of HRV.

  17. Changes in subcutaneous blood flow during locally applied negative pressure to the skin

    DEFF Research Database (Denmark)

    Skagen, K; Henriksen, O

    1983-01-01

    The effect of locally applied subatmospheric pressure on subcutaneous blood flow was studied in 12 healthy subjects. Blood flow was measured on the forearm by the local 133Xe wash-out technique. Air suction between 10 mmHg and 250 mmHg was applied to the skin. Subatmospheric pressure of 20 mm...

  18. Brachial versus central blood pressure and vascular stiffness

    DEFF Research Database (Denmark)

    Rasmussen, Susanne; Hansen, Tine; Frimodt-Møller, Marie

    2010-01-01

    Central blood pressure (BP) estimates the true load imposed on the left ventricle to a higher degree than does brachial BP. Increased aortic pulse wave velocity (aPWV) and central BP are risk markers for cardiovascular disease. Both can be measured by simple and noninvasive methods. Guidelines...

  19. Brachial versus central blood pressure and vascular stiffness

    DEFF Research Database (Denmark)

    Rasmussen, Susanne; Hansen, Tine; Frimodt-Møller, Marie

    2009-01-01

    Central blood pressure (BP) estimates the true load imposed on the left ventricle to a higher degree than does brachial BP. Increased aortic pulse wave velocity (aPWV) and central BP are risk markers for cardiovascular disease. Both can be measured by simple and noninvasive methods. Guidelines...

  20. High beat-to-beat blood pressure variability in atrial fibrillation compared to sinus rhythm.

    Science.gov (United States)

    Olbers, Joakim; Gille, Adam; Ljungman, Petter; Rosenqvist, Mårten; Östergren, Jan; Witt, Nils

    2018-02-07

    Atrial fibrillation (AF) is associated with an increased risk for cardiovascular morbidity and mortality, not entirely explained by thromboembolism. The underlying mechanisms for this association are largely unknown. Similarly, high blood pressure (BP) increases the risk for cardiovascular events. Despite this the interplay between AF and BP is insufficiently studied. The purpose of this study was to examine and quantify the beat-to-beat blood pressure variability in patients with AF in comparison to a control group of patients with sinus rhythm. We studied 33 patients - 21 in atrial fibrillation and 12 in sinus rhythm - undergoing routine coronary angiography. Invasive blood pressure was recorded at three locations: radial artery, brachial artery and ascending aorta. Blood pressure variability, defined as average beat-to-beat blood pressure difference, was calculated for systolic and diastolic blood pressure at each site. We observed a significant difference (p blood pressure variability between the atrial fibrillation and sinus rhythm groups at all locations. Systolic blood pressure variability roughly doubled in the atrial fibrillation group compared to the sinus rhythm group (4.9 and 2.4 mmHg respectively). Diastolic beat-to-beat blood pressure variability was approximately 6 times as high in the atrial fibrillation group compared to the sinus rhythm group (7.5 and 1.2 mmHg respectively). No significant difference in blood pressure variability was seen between measurement locations. Beat-to-beat blood pressure variability in patients with atrial fibrillation was substantially higher than in patients with sinus rhythm. Hemodynamic effects of this beat-to-beat variation in blood pressure may negatively affect vascular structure and function, which may contribute to the increased cardiovascular morbidity and mortality seen in patients with atrial fibrillation.