WorldWideScience

Sample records for maximum probing depth

  1. The maximum economic depth of groundwater abstraction for irrigation

    Science.gov (United States)

    Bierkens, M. F.; Van Beek, L. P.; de Graaf, I. E. M.; Gleeson, T. P.

    2017-12-01

    Over recent decades, groundwater has become increasingly important for agriculture. Irrigation accounts for 40% of the global food production and its importance is expected to grow further in the near future. Already, about 70% of the globally abstracted water is used for irrigation, and nearly half of that is pumped groundwater. In many irrigated areas where groundwater is the primary source of irrigation water, groundwater abstraction is larger than recharge and we see massive groundwater head decline in these areas. An important question then is: to what maximum depth can groundwater be pumped for it to be still economically recoverable? The objective of this study is therefore to create a global map of the maximum depth of economically recoverable groundwater when used for irrigation. The maximum economic depth is the maximum depth at which revenues are still larger than pumping costs or the maximum depth at which initial investments become too large compared to yearly revenues. To this end we set up a simple economic model where costs of well drilling and the energy costs of pumping, which are a function of well depth and static head depth respectively, are compared with the revenues obtained for the irrigated crops. Parameters for the cost sub-model are obtained from several US-based studies and applied to other countries based on GDP/capita as an index of labour costs. The revenue sub-model is based on gross irrigation water demand calculated with a global hydrological and water resources model, areal coverage of crop types from MIRCA2000 and FAO-based statistics on crop yield and market price. We applied our method to irrigated areas in the world overlying productive aquifers. Estimated maximum economic depths range between 50 and 500 m. Most important factors explaining the maximum economic depth are the dominant crop type in the area and whether or not initial investments in well infrastructure are limiting. In subsequent research, our estimates of

  2. Option-4 algorithm for Florida pocket depth probe: reduction in the variance of site-specific probeable crevice depth measurements.

    Science.gov (United States)

    Breen, H J; Rogers, P; Johnson, N W; Slaney, R

    1999-08-01

    Clinical periodontal measurement is plagued by many sources of error which result in aberrant values (outliers). This study sets out to compare probeable crevice depth measurements (PCD) selected by the option-4 algorithm against those recorded with a conventional double-pass method and to quantify any reduction in site-specific PCD variances. A single clinician recorded full-mouth PCD at 1 visit in 32 subjects (mean age 45.5 years) with moderately advanced chronic adult periodontitis. PCD was recorded over 2 passes at 6 sites per tooth with the Florida Pocket Depth Probes, a 3rd generation probe. The option-4 algorithm compared the 1st pass site-specific PCD value (PCD1) to the 2nd pass site-specific PCD value (PCD2) and, if the difference between these values was >1.00 mm, allowed the recording of a maximum of 2 further measurements (3rd and 4th pass measurements PCD3 and PCD4): 4 site-specific measure-meets were considered to be the maximum subject and tissue tolerance. The algorithm selected the 1st 2 measurements whose difference was difference Y) (Y=[(A-B)/A]X 100) and a 75% reduction in the median site-specific variance of PCD1/PCD2.

  3. Mid-depth temperature maximum in an estuarine lake

    Science.gov (United States)

    Stepanenko, V. M.; Repina, I. A.; Artamonov, A. Yu; Gorin, S. L.; Lykossov, V. N.; Kulyamin, D. V.

    2018-03-01

    The mid-depth temperature maximum (TeM) was measured in an estuarine Bol’shoi Vilyui Lake (Kamchatka peninsula, Russia) in summer 2015. We applied 1D k-ɛ model LAKE to the case, and found it successfully simulating the phenomenon. We argue that the main prerequisite for mid-depth TeM development is a salinity increase below the freshwater mixed layer, sharp enough in order to increase the temperature with depth not to cause convective mixing and double diffusion there. Given that this condition is satisfied, the TeM magnitude is controlled by physical factors which we identified as: radiation absorption below the mixed layer, mixed-layer temperature dynamics, vertical heat conduction and water-sediments heat exchange. In addition to these, we formulate the mechanism of temperature maximum ‘pumping’, resulting from the phase shift between diurnal cycles of mixed-layer depth and temperature maximum magnitude. Based on the LAKE model results we quantify the contribution of the above listed mechanisms and find their individual significance highly sensitive to water turbidity. Relying on physical mechanisms identified we define environmental conditions favouring the summertime TeM development in salinity-stratified lakes as: small-mixed layer depth (roughly, ~wind and cloudless weather. We exemplify the effect of mixed-layer depth on TeM by a set of selected lakes.

  4. Determination of the maximum-depth to potential field sources by a maximum structural index method

    Science.gov (United States)

    Fedi, M.; Florio, G.

    2013-01-01

    A simple and fast determination of the limiting depth to the sources may represent a significant help to the data interpretation. To this end we explore the possibility of determining those source parameters shared by all the classes of models fitting the data. One approach is to determine the maximum depth-to-source compatible with the measured data, by using for example the well-known Bott-Smith rules. These rules involve only the knowledge of the field and its horizontal gradient maxima, and are independent from the density contrast. Thanks to the direct relationship between structural index and depth to sources we work out a simple and fast strategy to obtain the maximum depth by using the semi-automated methods, such as Euler deconvolution or depth-from-extreme-points method (DEXP). The proposed method consists in estimating the maximum depth as the one obtained for the highest allowable value of the structural index (Nmax). Nmax may be easily determined, since it depends only on the dimensionality of the problem (2D/3D) and on the nature of the analyzed field (e.g., gravity field or magnetic field). We tested our approach on synthetic models against the results obtained by the classical Bott-Smith formulas and the results are in fact very similar, confirming the validity of this method. However, while Bott-Smith formulas are restricted to the gravity field only, our method is applicable also to the magnetic field and to any derivative of the gravity and magnetic field. Our method yields a useful criterion to assess the source model based on the (∂f/∂x)max/fmax ratio. The usefulness of the method in real cases is demonstrated for a salt wall in the Mississippi basin, where the estimation of the maximum depth agrees with the seismic information.

  5. In-vitro accuracy and reproducibility evaluation of probing depth measurements of selected periodontal probes

    Directory of Open Access Journals (Sweden)

    K.N. Al Shayeb

    2014-01-01

    Conclusion: Depth measurements with the Chapple UB-CF-15 probe were more accurate and reproducible compared to measurements with the Vivacare TPS and Williams 14 W probes. This in vitro model may be useful for intra-examiner calibration or clinician training prior to the clinical evaluation of patients or in longitudinal studies involving periodontal evaluation.

  6. TRENDS IN ESTIMATED MIXING DEPTH DAILY MAXIMUMS

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, R; Amy DuPont, A; Robert Kurzeja, R; Matt Parker, M

    2007-11-12

    Mixing depth is an important quantity in the determination of air pollution concentrations. Fireweather forecasts depend strongly on estimates of the mixing depth as a means of determining the altitude and dilution (ventilation rates) of smoke plumes. The Savannah River United States Forest Service (USFS) routinely conducts prescribed fires at the Savannah River Site (SRS), a heavily wooded Department of Energy (DOE) facility located in southwest South Carolina. For many years, the Savannah River National Laboratory (SRNL) has provided forecasts of weather conditions in support of the fire program, including an estimated mixing depth using potential temperature and turbulence change with height at a given location. This paper examines trends in the average estimated mixing depth daily maximum at the SRS over an extended period of time (4.75 years) derived from numerical atmospheric simulations using two versions of the Regional Atmospheric Modeling System (RAMS). This allows for differences to be seen between the model versions, as well as trends on a multi-year time frame. In addition, comparisons of predicted mixing depth for individual days in which special balloon soundings were released are also discussed.

  7. Probe depth matters in dermal microdialysis sampling of benzoic acid after topical application

    DEFF Research Database (Denmark)

    Holmgaard, R; Benfeldt, E; Bangsgaard, N

    2012-01-01

    -2 mm) and deep (>2 mm) positioning of the linear MD probe in the dermis of human abdominal skin, followed by topical application of 4 mg/ml of benzoic acid (BA) in skin chambers overlying the probes. Dialysate was sampled every hour for 12 h and analysed for BA content by high-performance liquid...... chromatography. Probe depth was measured by 20-MHz ultrasound scanning. The area under the time-versus-concentration curve (AUC) describes the drug exposure in the tissue during the experiment and is a relevant parameter to compare for the 3 dermal probe depths investigated. The AUC(0-12) were: superficial...... significantly different from each other (p value paper demonstrates that there is an inverse relationship between the depth of the probe in the dermis and the amount of drug sampled following topical penetration ex vivo. The result is of relevance to the in vivo situation, and it can...

  8. An indentation depth-force sensing wheeled probe for abnormality identification during minimally invasive surgery.

    Science.gov (United States)

    Liu, H; Puangmali, P; Zbyszewski, D; Elhage, O; Dasgupta, P; Dai, J S; Seneviratne, L; Althoefer, K

    2010-01-01

    This paper presents a novel wheeled probe for the purpose of aiding a surgeon in soft tissue abnormality identification during minimally invasive surgery (MIS), compensating the loss of haptic feedback commonly associated with MIS. Initially, a prototype for validating the concept was developed. The wheeled probe consists of an indentation depth sensor employing an optic fibre sensing scheme and a force/torque sensor. The two sensors work in unison, allowing the wheeled probe to measure the tool-tissue interaction force and the rolling indentation depth concurrently. The indentation depth sensor was developed and initially tested on a homogenous silicone phantom representing a good model for a soft tissue organ; the results show that the sensor can accurately measure the indentation depths occurring while performing rolling indentation, and has good repeatability. To validate the ability of the wheeled probe to identify abnormalities located in the tissue, the device was tested on a silicone phantom containing embedded hard nodules. The experimental data demonstrate that recording the tissue reaction force as well as rolling indentation depth signals during rolling indentation, the wheeled probe can rapidly identify the distribution of tissue stiffness and cause the embedded hard nodules to be accurately located.

  9. Simultaneous surface and depth neural activity recording with graphene transistor-based dual-modality probes.

    Science.gov (United States)

    Du, Mingde; Xu, Xianchen; Yang, Long; Guo, Yichuan; Guan, Shouliang; Shi, Jidong; Wang, Jinfen; Fang, Ying

    2018-05-15

    Subdural surface and penetrating depth probes are widely applied to record neural activities from the cortical surface and intracortical locations of the brain, respectively. Simultaneous surface and depth neural activity recording is essential to understand the linkage between the two modalities. Here, we develop flexible dual-modality neural probes based on graphene transistors. The neural probes exhibit stable electrical performance even under 90° bending because of the excellent mechanical properties of graphene, and thus allow multi-site recording from the subdural surface of rat cortex. In addition, finite element analysis was carried out to investigate the mechanical interactions between probe and cortex tissue during intracortical implantation. Based on the simulation results, a sharp tip angle of π/6 was chosen to facilitate tissue penetration of the neural probes. Accordingly, the graphene transistor-based dual-modality neural probes have been successfully applied for simultaneous surface and depth recording of epileptiform activity of rat brain in vivo. Our results show that graphene transistor-based dual-modality neural probes can serve as a facile and versatile tool to study tempo-spatial patterns of neural activities. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Multi-approach analysis of maximum riverbed scour depth above subway tunnel

    Directory of Open Access Journals (Sweden)

    Jun Chen

    2010-12-01

    Full Text Available When subway tunnels are routed underneath rivers, riverbed scour may expose the structure, with potentially severe consequences. Thus, it is important to identify the maximum scour depth to ensure that the designed buried depth is adequate. There are a range of methods that may be applied to this problem, including the fluvial process analysis method, geological structure analysis method, scour formula method, scour model experiment method, and numerical simulation method. However, the application ranges and forecasting precision of these methods vary considerably. In order to quantitatively analyze the characteristics of the different methods, a subway tunnel passing underneath a river was selected, and the aforementioned five methods were used to forecast the maximum scour depth. The fluvial process analysis method was used to characterize the river regime and evolution trend, which were the baseline for examination of the scour depth of the riverbed. The results obtained from the scour model experiment and the numerical simulation methods are reliable; these two methods are suitable for application to tunnel projects passing underneath rivers. The scour formula method was less accurate than the scour model experiment method; it is suitable for application to lower risk projects such as pipelines. The results of the geological structure analysis had low precision; the method is suitable for use as a secondary method to assist other research methods. To forecast the maximum scour depth of the riverbed above the subway tunnel, a combination of methods is suggested, and the appropriate analysis method should be chosen with respect to the local conditions.

  11. Multi-approach analysis of maximum riverbed scour depth above subway tunnel

    OpenAIRE

    Jun Chen; Hong-wu Tang; Zui-sen Li; Wen-hong Dai

    2010-01-01

    When subway tunnels are routed underneath rivers, riverbed scour may expose the structure, with potentially severe consequences. Thus, it is important to identify the maximum scour depth to ensure that the designed buried depth is adequate. There are a range of methods that may be applied to this problem, including the fluvial process analysis method, geological structure analysis method, scour formula method, scour model experiment method, and numerical simulation method. However, the applic...

  12. Assessment of geomechanical properties, maximum depth and excavation damaged zone aspects - Expert report

    International Nuclear Information System (INIS)

    Amann, F.; Löw, S.; Perras, M.

    2015-11-01

    This comprehensive report published by the Swiss National Nuclear Safety Inspectorate ENSI discusses the expert report published on the need for the assessment of geomechanical properties and maximum depth of repositories for high, medium and low-activity nuclear wastes. Also, aspects concerning excavation damaged zones (EDZ) are considered. These are all criteria for the selection of sites as part of Phase 2 of the Swiss waste disposal project. Four questions are examined: are NAGRA’s documented basic considerations and calculations on Opalinus Clay comprehensive enough and correct, are the calculations on maximum depth correct, are the proposed storage perimeters correct with respect to depth and will NAGRA be able to take possible excavation damaged zones (EDZ) into account? Literature and references concerning the subject are quoted

  13. Maximum Neutral Buoyancy Depth of Juvenile Chinook Salmon: Implications for Survival during Hydroturbine Passage

    Energy Technology Data Exchange (ETDEWEB)

    Pflugrath, Brett D.; Brown, Richard S.; Carlson, Thomas J.

    2012-03-01

    This study investigated the maximum depth at which juvenile Chinook salmon Oncorhynchus tshawytscha can acclimate by attaining neutral buoyancy. Depth of neutral buoyancy is dependent upon the volume of gas within the swim bladder, which greatly influences the occurrence of injuries to fish passing through hydroturbines. We used two methods to obtain maximum swim bladder volumes that were transformed into depth estimations - the increased excess mass test (IEMT) and the swim bladder rupture test (SBRT). In the IEMT, weights were surgically added to the fishes exterior, requiring the fish to increase swim bladder volume in order to remain neutrally buoyant. SBRT entailed removing and artificially increasing swim bladder volume through decompression. From these tests, we estimate the maximum acclimation depth for juvenile Chinook salmon is a median of 6.7m (range = 4.6-11.6 m). These findings have important implications to survival estimates, studies using tags, hydropower operations, and survival of juvenile salmon that pass through large Kaplan turbines typical of those found within the Columbia and Snake River hydropower system.

  14. A generic statistical methodology to predict the maximum pit depth of a localized corrosion process

    International Nuclear Information System (INIS)

    Jarrah, A.; Bigerelle, M.; Guillemot, G.; Najjar, D.; Iost, A.; Nianga, J.-M.

    2011-01-01

    Highlights: → We propose a methodology to predict the maximum pit depth in a corrosion process. → Generalized Lambda Distribution and the Computer Based Bootstrap Method are combined. → GLD fit a large variety of distributions both in their central and tail regions. → Minimum thickness preventing perforation can be estimated with a safety margin. → Considering its applications, this new approach can help to size industrial pieces. - Abstract: This paper outlines a new methodology to predict accurately the maximum pit depth related to a localized corrosion process. It combines two statistical methods: the Generalized Lambda Distribution (GLD), to determine a model of distribution fitting with the experimental frequency distribution of depths, and the Computer Based Bootstrap Method (CBBM), to generate simulated distributions equivalent to the experimental one. In comparison with conventionally established statistical methods that are restricted to the use of inferred distributions constrained by specific mathematical assumptions, the major advantage of the methodology presented in this paper is that both the GLD and the CBBM enable a statistical treatment of the experimental data without making any preconceived choice neither on the unknown theoretical parent underlying distribution of pit depth which characterizes the global corrosion phenomenon nor on the unknown associated theoretical extreme value distribution which characterizes the deepest pits. Considering an experimental distribution of depths of pits produced on an aluminium sample, estimations of maximum pit depth using a GLD model are compared to similar estimations based on usual Gumbel and Generalized Extreme Value (GEV) methods proposed in the corrosion engineering literature. The GLD approach is shown having smaller bias and dispersion in the estimation of the maximum pit depth than the Gumbel approach both for its realization and mean. This leads to comparing the GLD approach to the GEV one

  15. Aluminum-thin-film packaged fiber Bragg grating probes for monitoring the maximum tensile strain of composite materials.

    Science.gov (United States)

    Im, Jooeun; Kim, Mihyun; Choi, Ki-Sun; Hwang, Tae-Kyung; Kwon, Il-Bum

    2014-06-10

    In this paper, new fiber Bragg grating (FBG) sensor probes are designed to intermittently detect the maximum tensile strain of composite materials, so as to evaluate the structural health status. This probe is fabricated by two thin Al films bonded to an FBG optical fiber and two supporting brackets, which are fixed on the surface of composite materials. The residual strain of the Al packaged FBG sensor probe is induced by the strain of composite materials. This residual strain can indicate the maximum strain of composite materials. Two types of sensor probes are prepared-one is an FBG with 18 μm thick Al films, and the other is an FBG with 36 μm thick Al films-to compare the thickness effect on the detection sensitivity. These sensor probes are bonded on the surfaces of carbon fiber reinforced plastics composite specimens. In order to determine the strain sensitivity between the residual strain of the FBG sensor probe and the maximum strain of the composite specimen, tensile tests are performed by universal testing machine, under the loading-unloading test condition. The strain sensitivities of the probes, which have the Al thicknesses of 18 and 36 μm, are determined as 0.13 and 0.23, respectively.

  16. Soil texture and depth influence on the neutron probe calibration

    International Nuclear Information System (INIS)

    Santos, Reginaldo Ferreira; Carlesso, Reimar

    1998-01-01

    The neutron probe is an equipment used on determination of the soil water content, based on the fast neutron attenuation. Therefore, there is a calibration need in the field and, consequently, to verify the soil texture and depth influence for to determining the calibration curves in relation to the water content. The study was developed at Santa Maria's Federal University in a lisimeter group, protected from the rains with transparent plastic. There different soil textures, three depths (10, 30 and 50 cm from the soil surface) and four replicates were used. Linear regression equations between neutron counts and soil water contents were made. The results showed that there was interference of the texture and depth of the soil, analyzed jointly, on the calibration curves, and the observed and estimated values varied form o,02 to 0,06 cm3/cm3 of the soil water content and the correlation coefficients were 0,86 0,95 and 0,89 for clayray, franc-silt-clayey and franc-sandy, respectively. For soil texture and depth, analyzed separately, the differences among the values observed in the field and the estimated ones, varied from 0,0 to 0,02 cm3/cm3 soil water content and presented correlation coefficients between 0,97 and 1,0. (author)

  17. ABOUT RATIONING MAXIMUM ALLOWABLE DEFECT DEPTH ON THE SURFACE OF STEEL BILLETS IN PRODUCTION OF HOT-ROLLED STEEL

    Directory of Open Access Journals (Sweden)

    PARUSOV E. V.

    2017-01-01

    Full Text Available Formulation of the problem. Significant influence on the quality of rolled steel have various defects on its surface, which in its turn inherited from surface defects of billet and possible damage to the surface of rolled steel in the rolling mill line. One of the criteria for assessing the quality indicators of rolled steel is rationing of surface defects [1; 2; 3; 6; 7]. Current status of the issue. Analyzing the different requirements of regulations to the surface quality of the rolled high-carbon steels, we can conclude that the maximum allowable depth of defects on the surface of billet should be in the range of 2.0...5.0 mm (depending on the section of the billet, method of its production and further the destination Purpose. Develop a methodology for calculating the maximum allowable depth of defects on the steel billet surface depending on the requirements placed on the surface quality of hot-rolled steel. Results. A simplified method of calculation, allowing at the rated depth of defects on the surface of the hot-rolled steel to make operatively calculation of the maximum allowable depth of surface defects of steel billets before heating the metal in the heat deformation was developed. The findings shows that the maximum allowable depth of surface defects is reduced with increasing diameter rolled steel, reducing the initial section steel billet and degrees of oxidation of the metal in the heating furnace.

  18. The Hengill geothermal area, Iceland: Variation of temperature gradients deduced from the maximum depth of seismogenesis

    Science.gov (United States)

    Foulger, G. R.

    1995-04-01

    Given a uniform lithology and strain rate and a full seismic data set, the maximum depth of earthquakes may be viewed to a first order as an isotherm. These conditions are approached at the Hengill geothermal area S. Iceland, a dominantly basaltic area. The likely strain rate calculated from thermal and tectonic considerations is 10 -15 s -1, and temperature measurements from four drill sites within the area indicate average, near-surface geothermal gradients of up to 150 °C km -1 throughout the upper 2 km. The temperature at which seismic failure ceases for the strain rates likely at the Hengill geothermal area is determined by analogy with oceanic crust, and is about 650 ± 50 °C. The topographies of the top and bottom of the seismogenic layer were mapped using 617 earthquakes located highly accurately by performing a simultaneous inversion for three-dimensional structure and hypocentral parameters. The thickness of the seismogenic layer is roughly constant and about 3 km. A shallow, aseismic, low-velocity volume within the spreading plate boundary that crosses the area occurs above the top of the seismogenic layer and is interpreted as an isolated body of partial melt. The base of the seismogenic layer has a maximum depth of about 6.5 km beneath the spreading axis and deepens to about 7 km beneath a transform zone in the south of the area. Beneath the high-temperature part of the geothermal area, the maximum depth of earthquakes may be as shallow as 4 km. The geothermal gradient below drilling depths in various parts of the area ranges from 84 ± 9 °Ckm -1 within the low-temperature geothermal area of the transform zone to 138 ± 15 °Ckm -1 below the centre of the high-temperature geothermal area. Shallow maximum depths of earthquakes and therefore high average geothermal gradients tend to correlate with the intensity of the geothermal area and not with the location of the currently active spreading axis.

  19. Beveled fiber-optic probe couples a ball lens for improving depth-resolved fluorescence measurements of layered tissue: Monte Carlo simulations

    International Nuclear Information System (INIS)

    Jaillon, Franck; Zheng Wei; Huang Zhiwei

    2008-01-01

    In this study, we evaluate the feasibility of designing a beveled fiber-optic probe coupled with a ball lens for improving depth-resolved fluorescence measurements of epithelial tissue using Monte Carlo (MC) simulations. The results show that by using the probe configuration with a beveled tip collection fiber and a flat tip excitation fiber associated with a ball lens, discrimination of fluorescence signals generated in different tissue depths is achievable. In comparison with a flat-tip collection fiber, the use of a large bevel angled collection fiber enables a better differentiation between the shallow and deep tissue layers by changing the excitation-collection fiber separations. This work suggests that the beveled fiber-optic probe coupled with a ball lens has the potential to facilitate depth-resolved fluorescence measurements of epithelial tissues

  20. All-fiber probe for optical coherence tomography with an extended depth of focus by a high-efficient fiber-based filter

    Science.gov (United States)

    Qiu, Jianrong; Shen, Yi; Shangguan, Ziwei; Bao, Wen; Yang, Shanshan; Li, Peng; Ding, Zhihua

    2018-04-01

    Although methods have been proposed to maintain high transverse resolution over an increased depth range, it is not straightforward to scale down the bulk-optic solutions to minimized probes of optical coherence tomography (OCT). In this paper, we propose a high-efficient fiber-based filter in an all-fiber OCT probe to realize an extended depth of focus (DOF) while maintaining a high transverse resolution. Mode interference in the probe is exploited to modulate the complex field with controllable radial distribution. The principle of DOF extension by the fiber-based filter is theoretically analyzed. Numerical simulations are conducted to evaluate the performances of the designed probes. A DOF extension ratio of 2.6 over conventional Gaussian beam is obtainable in one proposed probe under a focused beam diameter of 4 . 6 μm. Coupling efficiencies of internal interfaces of the proposed probe are below -40 dB except the last probe-air interface, which can also be depressed to be -44 dB after minor modification in lengths for the filter. Length tolerance of the proposed probe is determined to be - 28 / + 20 μm, which is readily satisfied in fabrication. With the merits of extended-DOF, high-resolution, high-efficiency and easy-fabrication, the proposed probe is promising in endoscopic applications.

  1. Effects of countermovement depth on kinematic and kinetic patterns of maximum vertical jumps.

    Science.gov (United States)

    Mandic, Radivoj; Jakovljevic, Sasa; Jaric, Slobodan

    2015-04-01

    Although maximum height (H(max)), muscle force (F), and power output (P), have been routinely obtained from maximum vertical jumps for various purposes, a possible role of the countermovement depth (H(cmd)) on the same variables remains largely unexplored. Here we hypothesized that (1) the optimum H(cmd) for maximizing H(max) exists, while (2) an increase in H(cmd) would be associated with a decrease in both F and P. Professional male basketball players (N=11) preformed maximum countermovement jumps with and without arm swing while varying H(cmd)±25 cm from its preferred value. Although regression models revealed a presence of optimum H(cmd) for maximizing H(max), H(max) revealed only small changes within a wide range of H(cmd). The preferred H(cmd) was markedly below its optimum value (p vertical jumps should be taken with caution since both of them could be markedly confounded by H(cmd). Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. On the applicability of extreme value statistics in the prediction of maximum pit depth in heavily corroded non-piggable buried pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Alfonso, L. [Universidad Autonoma de la Ciudad de Mexico, Mexico D.F. 09790 (Mexico); Caleyo, F.; Hallen, J. M.; Araujo, J. [ESIQIE, Instituto Politecnico Nacional, Mexico D.F. (Mexico)

    2010-07-01

    Pitting corrosion entails serious risks in industrial plants, since a perforation resulting from a single pit can cause the failure of in-service components like water pipes, heat exchangers or oil tanks. A number of statistical methods have been suggested to estimate the maximum pit depth. Over the years, a successful application of extreme value analysis has been found in the application of the Gumbel distribution to predict the maximum pit depth from a smaller number of samples with small area. There is a lack of studies devoted to the applicability of the Gumbel method to the prediction of maximum pitting-corrosion depth. The aim of the work presented in this paper is to introduce a new strategy for the application of the Gumbel method in real pipelines. The methodology proposed is based on the fact that the clustered pattern of the pit depth distribution is less pronounced when the analysis is restricted to sections of the pipeline that exhibits similar characteristics.

  3. Measurement of the Depth of Maximum of Extensive Air Showers above 10(18) eV

    NARCIS (Netherlands)

    Abraham, J.; Abreu, P.; Aglietta, M.; Ahn, E. J.; Allard, D.; Allekotte, I.; Allen, J.; Alvarez-Muniz, J.; Ambrosio, M.; Anchordoqui, L.; Andringa, S.; Anticic, T.; Anzalone, A.; Aramo, C.; Arganda, E.; Arisaka, K.; Arqueros, F.; Asorey, H.; Assis, P.; Aublin, J.; Ave, M.; Avila, G.; Baecker, T.; Badagnani, D.; Balzer, M.; Barber, K. B.; Barroso, S. L. C.; Barbosa, A. F.; Baughman, B.; Bauleo, P.; Beatty, J. J.; Becker, B. R.; Becker, K. H.; Belletoile, A.; Bellido, J. A.; BenZvi, S.; Berat, C.; Bergmann, T.; Bertou, X.; Biermann, P. L.; Billoir, P.; Blanch-Bigas, O.; Blanco, F.; Blanco, M.; Bleve, C.; Bluemer, H.; Bohacova, M.; Boncioli, D.; Bonifazi, C.; Bonino, R.; Borodai, N.; Brack, J.; Brogueira, P.; Brown, W. C.; Bruijn, R.; Buchholz, P.; Bueno, A.; Burton, R. E.; Busca, N. G.; Caballero-Mora, K. S.; Caramete, L.; Caruso, R.; Castellina, A.; Catalano, O.; Cataldi, G.; Cazon, L.; Cester, R.; Chauvin, J.; Chiavassa, A.; Chinellato, J. A.; Chou, A.; Chudoba, J.; Clay, R. W.; Colombo, E.; Coluccia, M. R.; Conceicao, R.; Contreras, F.; Cook, H.; Cooper, M. J.; Coppens, J.; Cordier, A.; Cotti, U.; Coutu, S.; Covault, C. E.; Creusot, A.; Criss, A.; Cronin, J.; Curutiu, A.; Dagoret-Campagne, S.; Dallier, R.; Daumiller, K.; Dawson, B. R.; de Almeida, R. M.; De Domenico, M.; De Donato, C.; de Jong, S. J.; De la Vega, G.; de Mello Junior, W. J. M.; de Mello Neto, J. R. T.; De Mitri, I.; de Souza, V.; de Vries, K. D.; Decerprit, G.; del Peral, L.; Deligny, O.; Della Selva, A.; Delle Fratte, C.; Dembinski, H.; Di Giulio, C.; Diaz, J. C.; Diaz Castro, M. L.; Diep, P. N.; Dobrigkeit, C.; D'Olivo, J. C.; Dong, P. N.; Dorofeev, A.; dos Anjos, J. C.; Dova, M. T.; D'Urso, D.; Dutan, I.; DuVernois, M. A.; Ebr, J.; Engel, R.; Erdmann, M.; Escobar, C. O.; Etchegoyen, A.; Facal San Luis, P.; Falcke, H.; Farrar, G.; Fauth, A. C.; Fazzini, N.; Ferrero, A.; Fick, B.; Filevich, A.; Filipcic, A.; Fleck, I.; Fliescher, S.; Fracchiolla, C. E.; Fraenkel, E. D.; Froehlich, U.; Fulgione, W.; Gamarra, R. F.; Gambetta, S.; Garcia, B.; Garcia Gamez, D.; Garcia-Pinto, D.; Garrido, X.; Gelmini, G.; Gemmeke, H.; Ghia, P. L.; Giaccari, U.; Giller, M.; Glass, H.; Goggin, L. M.; Gold, M. S.; Golup, G.; Gomez Albarracin, F.; Gomez Berisso, M.; Goncalves, P.; Gonzalez, D.; Gonzalez, J. G.; Gora, D.; Gorgi, A.; Gouffon, P.; Gozzini, S. R.; Grashorn, E.; Grebe, S.; Grigat, M.; Grillo, A. F.; Guardincerri, Y.; Guarino, F.; Guedes, G. P.; Hague, J. D.; Halenka, V.; Hansen, P.; Harari, D.; Harmsma, S.; Harton, J. L.; Haungs, A.; Hebbeker, T.; Heck, D.; Herve, A. E.; Hojvat, C.; Holmes, V. C.; Homola, P.; Horandel, J. R.; Horneffer, A.; Hrabovsky, M.; Huege, T.; Hussain, M.; Iarlori, M.; Insolia, A.; Ionita, F.; Italiano, A.; Jiraskova, S.; Kadija, K.; Kaducak, M.; Kampert, K. H.; Karova, T.; Kasper, P.; Kegl, B.; Keilhauer, B.; Keivani, A.; Kelley, J.; Kemp, E.; Kieckhafer, R. M.; Klages, H. O.; Kleifges, M.; Kleinfeller, J.; Knapik, R.; Knapp, J.; Koang, D. -H.; Krieger, A.; Kroemer, O.; Kruppke-Hansen, D.; Kuehn, F.; Kuempel, D.; Kulbartz, K.; Kunka, N.; Kusenko, A.; La Rosa, G.; Lachaud, C.; Lago, B. L.; Lautridou, P.; Leao, M. S. A. B.; Lebrun, D.; Lebrun, P.; Lee, J.; Leigui de Oliveira, M. A.; Lemiere, A.; Letessier-Selvon, A.; Lhenry-Yvon, I.; Lopez, R.; Lopez Agueera, A.; Louedec, K.; Lozano Bahilo, J.; Lucero, A.; Ludwig, M.; Lyberis, H.; Maccarone, M. C.; Macolino, C.; Maldera, S.; Mandat, D.; Mantsch, P.; Mariazzi, A. G.; Marin, V.; Maris, I. C.; Marquez Falcon, H. R.; Marsella, G.; Martello, D.; Martinez Bravo, O.; Mathes, H. J.; Matthews, J.; Matthews, J. A. J.; Matthiae, G.; Maurizio, D.; Mazur, P. O.; McEwen, M.; Medina-Tanco, G.; Melissas, M.; Melo, D.; Menichetti, E.; Menshikov, A.; Meurer, C.; Micanovic, S.; Micheletti, M. I.; Miller, W.; Miramonti, L.; Mollerach, S.; Monasor, M.; Ragaigne, D. Monnier; Montanet, F.; Morales, B.; Morello, C.; Moreno, E.; Moreno, J. C.; Morris, C.; Mostafa, M.; Mueller, S.; Muller, M. A.; Mussa, R.; Navarra, G.; Navarro, J. L.; Navas, S.; Necesal, P.; Nellen, L.; Nhung, P. T.; Nierstenhoefer, N.; Nitz, D.; Nosek, D.; Nozka, L.; Nyklicek, M.; Oehlschlaeger, J.; Olinto, A.; Oliva, P.; Olmos-Gilbaja, V. M.; Ortiz, M.; Pacheco, N.; Pakk Selmi-Dei, D.; Palatka, M.; Pallotta, J.; Palmieri, N.; Parente, G.; Parizot, E.; Parlati, S.; Parra, A.; Parrisius, J.; Parsons, R. D.; Pastor, S.; Paul, T.; Pavlidou, V.; Payet, K.; Pech, M.; Pekala, J.; Pelayo, R.; Pepe, I. M.; Perrone, L.; Pesce, R.; Petermann, E.; Petrera, S.; Petrinca, P.; Petrolini, A.; Petrov, Y.; Petrovic, J.; Pfendner, C.; Piegaia, R.; Pierog, T.; Pimenta, M.; Pirronello, V.; Platino, M.; Ponce, V. H.; Pontz, M.; Privitera, P.; Prouza, M.; Quel, E. J.; Rautenberg, J.; Ravel, O.; Ravignani, D.; Redondo, A.; Revenu, B.; Rezende, F. A. S.; Ridky, J.; Riggi, S.; Risse, M.; Ristori, P.; Riviere, C.; Rizi, V.; Robledo, C.; Rodriguez, G.; Rodriguez Martino, J.; Rodriguez Rojo, J.; Rodriguez-Cabo, I.; Rodriguez-Frias, M. D.; Ros, G.; Rosado, J.; Rossler, T.; Roth, M.; Rouille-d'Orfeuil, B.; Roulet, E.; Rovero, A. C.; Salamida, F.; Salazar, H.; Salina, G.; Sanchez, F.; Santander, M.; Santo, C. E.; Santos, E.; Santos, E. M.; Sarazin, F.; Sarkar, S.; Sato, R.; Scharf, N.; Scherini, V.; Schieler, H.; Schiffer, P.; Schmidt, A.; Schmidt, F.; Schmidt, T.; Scholten, O.; Schoorlemmer, H.; Schovancova, J.; Schovanek, P.; Schroeder, F.; Schulte, S.; Schuessler, F.; Schuster, D.; Sciutto, S. J.; Scuderi, M.; Segreto, A.; Semikoz, D.; Settimo, M.; Shadkam, A.; Shellard, R. C.; Sidelnik, I.; Siffert, B. B.; Sigl, G.; Smialkowski, A.; Smida, R.; Snow, G. R.; Sommers, P.; Sorokin, J.; Spinka, H.; Squartini, R.; Stasielak, J.; Stephan, M.; Strazzeri, E.; Stutz, A.; Suarez, F.; Suomijarvi, T.; Supanitsky, A. D.; Susa, T.; Sutherland, M. S.; Swain, J.; Szadkowski, Z.; Tamashiro, A.; Tamburro, A.; Tapia, A.; Tarutina, T.; Tascau, O.; Tcaciuc, R.; Tcherniakhovski, D.; Tegolo, D.; Thao, N. T.; Thomas, D.; Tiffenberg, J.; Timmermans, C.; Tkaczyk, W.; Todero Peixoto, C. J.; Tome, B.; Tonachini, A.; Travnicek, P.; Tridapalli, D. B.; Tristram, G.; Trovato, E.; Tueros, M.; Ulrich, R.; Unger, M.; Urban, M.; Valdes Galicia, J. F.; Valino, I.; Valore, L.; van den Berg, A. M.; Vazquez, J. R.; Vazquez, R. A.; Veberic, D.; Venters, T.; Verzi, V.; Videla, M.; Villasenor, L.; Vorobiov, S.; Voyvodic, L.; Wahlberg, H.; Wahrlich, P.; Wainberg, O.; Warner, D.; Watson, A. A.; Westerhoff, S.; Whelan, B. J.; Wieczorek, G.; Wiencke, L.; Wilczynska, B.; Wilczynski, H.; Williams, C.; Winchen, T.; Winnick, M. G.; Wundheiler, B.; Yamamoto, T.; Younk, P.; Yuan, G.; Yushkov, A.; Zas, E.; Zavrtanik, D.; Zavrtanik, M.; Zaw, I.; Zepeda, A.; Ziolkowski, M.

    2010-01-01

    We describe the measurement of the depth of maximum, X-max, of the longitudinal development of air showers induced by cosmic rays. Almost 4000 events above 10(18) eV observed by the fluorescence detector of the Pierre Auger Observatory in coincidence with at least one surface detector station are

  4. Monte Carlo simulation of the electron and X-ray depth distribution for quantitative electron probe microanalysis of PWR spent fuels

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyoung Mun; Lee, Hyung Kwon; Son, Young Zoon; Chun, Yong Bum [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-10-15

    Electron probe microanalysis requires several corrections to quantify an element of a specimen. The X-rays produced by the primary beam are created at some depth in the specimen. This distribution is usually represented as the function {Phi}(pz), and it is possible to calculate the correction factors for atomic number and absorption effects. The electron and X-ray depth distributions for a quantitative electron probe micro analysis were simulated by the CASINO Monte Carlo program to quantify some elements of the PWR spent fuel with 50 GWd/tU of burnup and 2 years of cooling time

  5. Monte Carlo simulation of the electron and X-ray depth distribution for quantitative electron probe microanalysis of PWR spent fuels

    International Nuclear Information System (INIS)

    Kwon, Hyoung Mun; Lee, Hyung Kwon; Son, Young Zoon; Chun, Yong Bum

    2011-01-01

    Electron probe microanalysis requires several corrections to quantify an element of a specimen. The X-rays produced by the primary beam are created at some depth in the specimen. This distribution is usually represented as the function Φ(pz), and it is possible to calculate the correction factors for atomic number and absorption effects. The electron and X-ray depth distributions for a quantitative electron probe micro analysis were simulated by the CASINO Monte Carlo program to quantify some elements of the PWR spent fuel with 50 GWd/tU of burnup and 2 years of cooling time

  6. At site and regional analysis of maximum annual and seasonal discharges and precipitation depths in the upper Hron region

    International Nuclear Information System (INIS)

    Kohnova, S.; Hlavcova, K.

    2004-01-01

    In this presentation authors deal with the regional analysis of maximum annual and seasonal discharges and precipitation depths in the upper Hron region (Slovak Republic). This work has two objectives: (1) At site and regional analysis of annual and seasonal maximum design discharges in the upper Hron region; (2) Analysis of annual and seasonal maximum design precipitations in the connection of extreme runoff condition in the upper Hron region

  7. Depth Probing Soft X-ray Microprobe (DPSXRM) for High Resolution Probing of Earth's Microstructural Samples

    Science.gov (United States)

    Dikedi, P. N.

    2015-12-01

    The Cambrian explosion; occurrence of landslides in very dry weather conditions; rockslides; dead, shriveled-up and crumbled leaves possessing fossil records with the semblance of well preserved, flat leaves; abundance of trilobite tracks in lower and higher rock layers; and sailing stones are enigmas demanding demystifications. These enigmas could be elucidated when data on soil structure, texture and strength are provided by some device with submicrometre accuracy; for these and other reasons, the design of a Depth Probing Soft X-ray Microprobe (DPSXRM), is being proposed; it is expected to deliver soft X-rays, at spatial resolution, ϛ≥600nm and to probe at the depth of 0.5m in 17s. The microprobe is portable compared to a synchrotron radiation facility (Diamond Light Source has land size of 43,300m2); spatial resolution,ϛ , of the DPSXRM surpasses those of the X-ray Fluorescence microanalysis (10µm), electron microprobe (1-3µm) and ion microprobe (5->30µm); the DPSXRM has allowance for multiple targets. Vanadium and Manganese membranes are proposed owing to respective 4.952KeV VKα1 and 5.899KeV MnKα1 X-rays emitted, which best suits micro-probing of Earth's microstructural samples. Compound systems like the Kirk-Patrick and Baez and Wolter optics, aspheric mirrors like elliptical and parabolic optics, small apertures and Abbe sine condition are employed to reduce or remove astigmatism, obliquity, comatic and spherical aberrations—leading to good image quality. Results show that 5.899KeV MnKα1 and 4.952KeV VKα1 soft X-rays will travel a distance of 2.75mm to form circular patches of radii 2.2mm and 2.95mm respectively. Zone plate with nth zone radius of 1.5mm must be positioned 1.5mm and 2mm from the electron gun if circular patches must be formed from 4.952KeV VKα1 and 5.899KeV MnKα1 soft X-rays respectively. The focal lengths of 0.25μm≤ƒ≤1.50μm and 0.04μm≤ƒ≤0.2μm covered by 4.952KeV VKα1 and 5.899KeV Mn Kα1 soft X-Rays, will

  8. The Hengill geothermal area, Iceland: variation of temperature gradients deduced from the maximum depth of seismogenesis

    Science.gov (United States)

    Foulger, G.R.

    1995-01-01

    Given a uniform lithology and strain rate and a full seismic data set, the maximum depth of earthquakes may be viewed to a first order as an isotherm. These conditions are approached at the Hengill geothermal area, S. Iceland, a dominantly basaltic area. The temperature at which seismic failure ceases for the strain rates likely at the Hengill geothermal area is determined by analogy with oceanic crust, and is about 650 ?? 50??C. The topographies of the top and bottom of the seismogenic layer were mapped using 617 earthquakes. The thickness of the seismogenic layer is roughly constant and about 3 km. A shallow, aseismic, low-velocity volume within the spreading plate boundary that crosses the area occurs above the top of the seismogenic layer and is interpreted as an isolated body of partial melt. The base of the seismogenic layer has a maximum depth of about 6.5 km beneath the spreading axis and deepens to about 7 km beneath a transform zone in the south of the area. -from Author

  9. Spatio-temporal distribution of Diaphanosoma brachyurum (Cladocera: Sididae in freshwater reservoir ecosystems: importance of maximum water depth and macrophyte beds for avoidance of fish predation

    Directory of Open Access Journals (Sweden)

    Jong-Yun Choi

    2014-10-01

    Full Text Available In empirical studies, Cladocera is commonly utilized as a primary food source for predators such as fish, thus, predator avoidance are important strategies to sustain their population in freshwater ecosystems. In this study, we tested the hypothesis that water depth is an important factor in determining the spatial distribution of Diaphanosoma brachyurum Liévin, 1848 in response to fish predation. Quarterly monitoring was implemented at three water layers (i.e., water surface and middle and bottom layers in 21 reservoirs located in the southeastern part of South Korea. D. brachyurum individuals were frequently observed at the study sites and exhibited different spatial patterns of distribution in accordance with the maximum depth of the reservoirs. In the reservoirs with a maximum depth of more than 6 m, high densities of D. brachyurum were observed in the bottom layers; however, in the shallower reservoirs (maximum depth <6 m, D. brachyurum were concentrated in the surface layer. Moreover, during additional surveys, we observed a trend in which D. brachyurum densities increased as the maximum depth or macrophyte biomass increased. Gut contents analysis revealed that predatory fishes in each reservoir frequently consumed D. brachyurum; however, the consumption rate abruptly decreased in reservoirs where the maximum depth was more than 11 m or in the shallow reservoirs supporting a macrophyte bed. Interestingly, the reservoirs more than 11-m depth supported high densities of D. brachyurum in the bottom layer and in the surface macrophyte bed. Based on these results, reservoirs with a maximum depth of more than 11 m or those with a macrophyte bed may provide a refuge for D. brachyurum to avoid fish predation. Compared with other cladoceran species, D. brachyurum readily exploits various types of refugia (in this study, the deep layer or surface macrophyte bed, which may help explain why this species is abundant in various types of reservoirs.

  10. Countermovement depth - a variable which clarifies the relationship between the maximum power output and height of a vertical jump.

    Science.gov (United States)

    Gajewski, Jan; Michalski, Radosław; Buśko, Krzysztof; Mazur-Różycka, Joanna; Staniak, Zbigniew

    2018-01-01

    The aim of this study was to identify the determinants of peak power achieved during vertical jumps in order to clarify relationship between the height of jump and the ability to exert maximum power. One hundred young (16.8±1.8 years) sportsmen participated in the study (body height 1.861 ± 0.109 m, body weight 80.3 ± 9.2 kg). Each participant performed three jump tests: countermovement jump (CMJ), akimbo countermovement jump (ACMJ), and spike jump (SPJ). A force plate was used to measure ground reaction force and to determine peak power output. The following explanatory variables were included in the model: jump height, body mass, and the lowering of the centre of mass before launch (countermovement depth). A model was created using multiple regression analysis and allometric scaling. The model was used to calculate the expected power value for each participant, which correlated strongly with real values. The value of the coefficient of determination R2 equalled 0.89, 0.90 and 0.98, respectively, for the CMJ, ACMJ, and SPJ jumps. The countermovement depth proved to be a variable strongly affecting the maximum power of jump. If the countermovement depth remains constant, the relative peak power is a simple function of jump height. The results suggest that the jump height of an individual is an exact indicator of their ability to produce maximum power. The presented model has a potential to be utilized under field condition for estimating the maximum power output of vertical jumps.

  11. Control strategy of maximum vertical jumps: The preferred countermovement depth may not be fully optimized for jump height

    Directory of Open Access Journals (Sweden)

    Mandic Radivoj

    2016-09-01

    Full Text Available The aim of the present study was to explore the control strategy of maximum countermovement jumps regarding the preferred countermovement depth preceding the concentric jump phase. Elite basketball players and physically active non-athletes were tested on the jumps performed with and without an arm swing, while the countermovement depth was varied within the interval of almost 30 cm around its preferred value. The results consistently revealed 5.1-11.2 cm smaller countermovement depth than the optimum one, but the same difference was more prominent in non-athletes. In addition, although the same differences revealed a marked effect on the recorded force and power output, they reduced jump height for only 0.1-1.2 cm. Therefore, the studied control strategy may not be based solely on the countermovement depth that maximizes jump height. In addition, the comparison of the two groups does not support the concept of a dual-task strategy based on the trade-off between maximizing jump height and minimizing the jumping quickness that should be more prominent in the athletes that routinely need to jump quickly. Further research could explore whether the observed phenomenon is based on other optimization principles, such as the minimization of effort and energy expenditure. Nevertheless, future routine testing procedures should take into account that the control strategy of maximum countermovement jumps is not fully based on maximizing the jump height, while the countermovement depth markedly confound the relationship between the jump height and the assessed force and power output of leg muscles.

  12. Control strategy of maximum vertical jumps: The preferred countermovement depth may not be fully optimized for jump height.

    Science.gov (United States)

    Mandic, Radivoj; Knezevic, Olivera M; Mirkov, Dragan M; Jaric, Slobodan

    2016-09-01

    The aim of the present study was to explore the control strategy of maximum countermovement jumps regarding the preferred countermovement depth preceding the concentric jump phase. Elite basketball players and physically active non-athletes were tested on the jumps performed with and without an arm swing, while the countermovement depth was varied within the interval of almost 30 cm around its preferred value. The results consistently revealed 5.1-11.2 cm smaller countermovement depth than the optimum one, but the same difference was more prominent in non-athletes. In addition, although the same differences revealed a marked effect on the recorded force and power output, they reduced jump height for only 0.1-1.2 cm. Therefore, the studied control strategy may not be based solely on the countermovement depth that maximizes jump height. In addition, the comparison of the two groups does not support the concept of a dual-task strategy based on the trade-off between maximizing jump height and minimizing the jumping quickness that should be more prominent in the athletes that routinely need to jump quickly. Further research could explore whether the observed phenomenon is based on other optimization principles, such as the minimization of effort and energy expenditure. Nevertheless, future routine testing procedures should take into account that the control strategy of maximum countermovement jumps is not fully based on maximizing the jump height, while the countermovement depth markedly confound the relationship between the jump height and the assessed force and power output of leg muscles.

  13. Maximum material thickness for extreme ultra-violet and X-ray backlighter probing of dense plasma

    International Nuclear Information System (INIS)

    Huang, H.; Tallents, G.J.

    2008-01-01

    Extreme ultra-violet (EUV) lasers, X-ray lasers and other backlighter sources can be used to probe high-energy density materials if their brightness can overcome self-emission from the material. We investigate the maximum plasma thickness of aluminum, silicon and iron that can be probed with EUV or X-ray photons of energy 89-1243 eV before self-emission from the plasma overwhelms the backlighter output. For a uniform plasma, backlighter transmission decreases exponentially with increasing thickness of the material following Beer's law at a rate dependent on the plasma opacity. We evaluate the plasma opacity with the Los Alamos TOPS opacity data. The self-emission is assumed to be either that of a black body to arise from a plasma in LTE or to only consist of free-free and free-bound emission. It is shown that at higher plasma temperature (≥40 eV), EUV radiation (e.g. photon energy=89 eV) can probe a greater thickness of plasma than X-ray radiation (e.g. photon energy=1243 eV)

  14. Measurement of the Depth of Maximum of Extensive Air Showers above 10^18 eV

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, J.; /Buenos Aires, CONICET; Abreu, P.; /Lisbon, IST; Aglietta, M.; /Turin U. /INFN, Turin; Ahn, E.J.; /Fermilab; Allard, D.; /APC, Paris; Allekotte, I.; /Centro Atomico Bariloche /Buenos Aires, CONICET; Allen, J.; /New York U.; Alvarez-Muniz, J.; /Santiago de Compostela U.; Ambrosio, M.; /Naples U.; Anchordoqui, L.; /Wisconsin U., Milwaukee; Andringa, S.; /Lisbon, IST /Boskovic Inst., Zagreb

    2010-02-01

    We describe the measurement of the depth of maximum, X{sub max}, of the longitudinal development of air showers induced by cosmic rays. Almost 4000 events above 10{sup 18} eV observed by the fluorescence detector of the Pierre Auger Observatory in coincidence with at least one surface detector station are selected for the analysis. The average shower maximum was found to evolve with energy at a rate of (106{sub -21}{sup +35}) g/cm{sup 2}/decade below 10{sup 18.24 {+-} 0.05}eV, and (24 {+-} 3) g/cm{sup 2}/decade above this energy. The measured shower-to-shower fluctuations decrease from about 55 to 26 g/cm{sup 2}. The interpretation of these results in terms of the cosmic ray mass composition is briefly discussed.

  15. The deconvolution of sputter-etching surface concentration measurements to determine impurity depth profiles

    International Nuclear Information System (INIS)

    Carter, G.; Katardjiev, I.V.; Nobes, M.J.

    1989-01-01

    The quasi-linear partial differential continuity equations that describe the evolution of the depth profiles and surface concentrations of marker atoms in kinematically equivalent systems undergoing sputtering, ion collection and atomic mixing are solved using the method of characteristics. It is shown how atomic mixing probabilities can be deduced from measurements of ion collection depth profiles with increasing ion fluence, and how this information can be used to predict surface concentration evolution. Even with this information, however, it is shown that it is not possible to deconvolute directly the surface concentration measurements to provide initial depth profiles, except when only ion collection and sputtering from the surface layer alone occur. It is demonstrated further that optimal recovery of initial concentration depth profiles could be ensured if the concentration-measuring analytical probe preferentially sampled depths near and at the maximum depth of bombardment-induced perturbations. (author)

  16. Depth sectioning using electron energy loss spectroscopy

    International Nuclear Information System (INIS)

    D'Alfonso, A J; Findlay, S D; Allen, L J; Cosgriff, E C; Kirkland, A I; Nellist, P D; Oxley, M P

    2008-01-01

    The continued development of electron probe aberration correctors for scanning transmission electron microscopy has enabled finer electron probes, allowing atomic resolution column-by-column electron energy loss spectroscopy. Finer electron probes have also led to a decrease in the probe depth of focus, facilitating optical slicing or depth sectioning of samples. The inclusion of post specimen aberration corrected image forming lenses allows for scanning confocal electron microscopy with further improved depth resolution and selectivity. We show that in both scanning transmission electron microscopy and scanning confocal electron microscopy geometries, by performing a three dimensional raster scan through a specimen and detecting electrons scattered with a characteristic energy loss, it will be possible to determine the location of isolated impurities embedded within the bulk.

  17. Similar mid-depth Atlantic water mass provenance during the Last Glacial Maximum and Heinrich Stadial 1

    Science.gov (United States)

    Howe, Jacob N. W.; Huang, Kuo-Fang; Oppo, Delia W.; Chiessi, Cristiano M.; Mulitza, Stefan; Blusztajn, Jurek; Piotrowski, Alexander M.

    2018-05-01

    The delivery of freshwater to the North Atlantic during Heinrich Stadial 1 (HS1) is thought to have fundamentally altered the operation of Atlantic meridional overturning circulation (AMOC). Although benthic foraminiferal carbon isotope records from the mid-depth Atlantic show a pronounced excursion to lower values during HS1, whether these shifts correspond to changes in water mass proportions, advection, or shifts in the carbon cycle remains unclear. Here we present new deglacial records of authigenic neodymium isotopes - a water mass tracer that is independent of the carbon cycle - from two cores in the mid-depth South Atlantic. We find no change in neodymium isotopic composition, and thus water mass proportions, between the Last Glacial Maximum (LGM) and HS1, despite large decreases in carbon isotope values at the onset of HS1 in the same cores. We suggest that the excursions of carbon isotopes to lower values were likely caused by the accumulation of respired organic matter due to slow overturning circulation, rather than to increased southern-sourced water, as typically assumed. The finding that there was little change in water mass provenance in the mid-depth South Atlantic between the LGM and HS1, despite decreased overturning, suggests that the rate of production of mid-depth southern-sourced water mass decreased in concert with decreased production of northern-sourced intermediate water at the onset of HS1. Consequently, we propose that even drastic changes in the strength of AMOC need not cause a significant change in South Atlantic mid-depth water mass proportions.

  18. On the control of irrigation through soil moisture measurement using a neutron depth probe in horizontal subsurface measuring circuits

    International Nuclear Information System (INIS)

    Schaecke, B.; Schaecke, E.

    1977-01-01

    An outline is given of the advantages inherent in soil moisture measurement by means of a neutron probe in horizontal subsurface measuring circuits for irrigation control. Preliminary experience for the setting up of a field calibration curve and for practical measurement are submitted. This technique includes the following advantages: almost complete covering of the upper soil range which is of interest to irrigation control; good measuring density; suitable distribution of measuring points per unit area; possibility of continuous probe passage; optimal repeatability of measurements; exploration of a unit area with but few measuring circuits; no obstacles to tillage, drilling, intercultivation and harvest operations; and complete conservation of crop and plot which is not reached with any other soil moisture measurement technique so far available. Making use of the above advantages, the new technique allows automatic irrigation control with only one neutron depth probe. (author)

  19. A simulation study of Linsley's approach to infer elongation rate and fluctuations of the EAS maximum depth from muon arrival time distributions

    International Nuclear Information System (INIS)

    Badea, A.F.; Brancus, I.M.; Rebel, H.; Haungs, A.; Oehlschlaeger, J.; Zazyan, M.

    1999-01-01

    The average depth of the maximum X m of the EAS (Extensive Air Shower) development depends on the energy E 0 and the mass of the primary particle, and its dependence from the energy is traditionally expressed by the so-called elongation rate D e defined as change in the average depth of the maximum per decade of E 0 i.e. D e = dX m /dlog 10 E 0 . Invoking the superposition model approximation i.e. assuming that a heavy primary (A) has the same shower elongation rate like a proton, but scaled with energies E 0 /A, one can write X m = X init + D e log 10 (E 0 /A). In 1977 an indirect approach studying D e has been suggested by Linsley. This approach can be applied to shower parameters which do not depend explicitly on the energy of the primary particle, but do depend on the depth of observation X and on the depth X m of shower maximum. The distribution of the EAS muon arrival times, measured at a certain observation level relatively to the arrival time of the shower core reflect the pathlength distribution of the muon travel from locus of production (near the axis) to the observation locus. The basic a priori assumption is that we can associate the mean value or median T of the time distribution to the height of the EAS maximum X m , and that we can express T = f(X,X m ). In order to derive from the energy variation of the arrival time quantities information about elongation rate, some knowledge is required about F i.e. F = - ∂ T/∂X m ) X /∂(T/∂X) X m , in addition to the variations with the depth of observation and the zenith-angle (θ) dependence, respectively. Thus ∂T/∂log 10 E 0 | X = - F·D e ·1/X v ·∂T/∂secθ| E 0 . In a similar way the fluctuations σ(X m ) of X m may be related to the fluctuations σ(T) of T i.e. σ(T) = - σ(X m )· F σ ·1/X v ·∂T/∂secθ| E 0 , with F σ being the corresponding scaling factor for the fluctuation of F. By simulations of the EAS development using the Monte Carlo code CORSIKA the energy and angle

  20. RELATIONSHIPS BETWEEN INITIAL PROBING DEPTH AND CHANGES IN THE CLINICAL PARAMETERS FOLLOWING NON-SURGICAL PERIODONTAL TREATMENT IN CHRONIC PERIODONTITIS

    Directory of Open Access Journals (Sweden)

    Süleyman Emre MESELİ

    2017-10-01

    Full Text Available Purpose: The aim of this study was to evaluate the relationship between initial probing depth (IPD and changes in clinical parameters following non-surgical periodontal treatment (NPT in chronic periodontitis patients. Subjects and Methods: A total of 1672 periodontal pockets having 3mm≤IPD≤9mm of depth in 15 chronic periodontitis patients were included. NPT consisting of oral hygiene instructions, scaling and root planing was applied in two sessions. Probing depth (PD, clinical attachment level, gingival recessions (GR were measured before and eight weeks after treatment. Pocket sites were grouped according to their IPD and root number as single- or multi-rooted teeth. Results: Other than the sites having 3 mm IPD, PD reduction and GR increase were significant in all groups (p<0.001. Attachment gains (AG were significant in all single-rooted teeth (p<0.001 again except those having IPD=3mm. However, AG was significant in multi-rooted teeth having only 7mm≤IPD≤9mm (p<0.05. Positive correlations were observed between IPD and PD reduction, GR increase and AG in single-rooted teeth (p<0.001. Furthermore, positive correlations were found between IPD and PD reduction and GR increase in multi-rooted teeth (p<0.001, but there was no correlation between IPD and AG. Conclusion: NPT may lead to positive association between IPD and PD reduction as well as GR increase, which is independent from tooth root anatomy.

  1. Microscopic measurement of penetration depth in YBa2Cu3O7-δ thin films by scanning Hall probe microscopy

    International Nuclear Information System (INIS)

    Oral, A.; Bending, S.J.; Humphreys, R.G.; Henini, M.

    1997-01-01

    We have used a low noise scanning Hall probe microscope to measure the penetration depth microscopically in a YBa 2 Cu 3 O 7-δ thin film as a function of temperature. The instrument has high magnetic field (approx. 2.9x10 -8 T Hz -1/2 at 77 K) and spatial resolution (approx. 0.85 μm). Magnetic field profiles of single vortices in the superconducting film have been successfully measured and the microscopic penetration depth of the superconductor has been extracted. We find surprisingly large variations in values of λ for different vortices within the scanning field. (author)

  2. Do different probing depths exhibit striking differences in microbial profiles?

    Science.gov (United States)

    Pérez-Chaparro, Paula Juliana; McCulloch, John Anthony; Mamizuka, Elsa Masae; Moraes, Aline da Costa Lima; Faveri, Marcelo; Figueiredo, Luciene Cristina; Duarte, Poliana Mendes; Feres, Magda

    2018-01-01

    To perform a thorough characterization of the subgingival microbiota of shallow, moderate and deep sites in subjects with chronic periodontitis (ChP). Subgingival samples were collected from subjects with ChP (n = 3/category of probing depth: ≤3, 4-6 and ≥7 mm) and periodontal health (PH). Individual samples were submitted to 16S rDNA high- throughput sequencing and the analysis was made using mothur and R packages. Nine subjects with ChP and seven with PH were included and 101 samples were evaluated. Thirteen phyla, 118 genera and 211 OTUs were detected. Taxa from Chloroflexi and Spirochaetes phyla were associated with initial stages of disease. Fretibacterium, Eubacterium[XI][G-6], Desulfobulbus, Peptostreptococcaceae[XI][G-1] and [G-3], Bacteroidetes[G-3], Bacteroidaceae[G-1] genera and Filifactor alocis, Fretibacterium fastidiosum, Johnsonella spHOT166, Peptostreptococcaceae[XIII][G-1]HOT113, Porphyromonas endodontalis and Treponema sp. HOT258, which are not conventionally associated with disease, increased with the deepening of the pockets and/or were elevated in ChP; while Streptococcus, Corynebacterium and Bergeyella genera were associated with PH (p oral microorganisms and newly identified periodontal taxa, some of them not-yet-cultured. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Interpretation of the depths of maximum of extensive air showers measured by the Pierre Auger Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, Pedro; et al.

    2013-02-01

    To interpret the mean depth of cosmic ray air shower maximum and its dispersion, we parametrize those two observables as functions of the first two moments of the ln A distribution. We examine the goodness of this simple method through simulations of test mass distributions. The application of the parameterization to Pierre Auger Observatory data allows one to study the energy dependence of the mean ln A and of its variance under the assumption of selected hadronic interaction models. We discuss possible implications of these dependences in term of interaction models and astrophysical cosmic ray sources.

  4. Evidence of localized amorphous silicon clustering from Raman depth-probing of silicon nanocrystals in fused silica

    International Nuclear Information System (INIS)

    Barba, D; Martin, F; Ross, G G

    2008-01-01

    Silicon nanocrystals (Si-nc) and amorphous silicon (α-Si) produced by silicon implantation in fused silica have been studied by micro-Raman spectroscopy. Information regarding the Raman signature of the α-Si phonon excitation was extracted from Raman depth-probing measurements using the phenomenological phonon confinement model. The spectral deconvolution of the Raman measurements recorded at different laser focusing depths takes into account both the Si-nc size variation and the Si-nc spatial distribution within the sample. The phonon peak associated with α-Si around 470 cm -1 is greatest for in-sample laser focusing, indicating that the formation of amorphous silicon is more important in the region containing a high concentration of silicon excess, where large Si-nc are located. As also observed for Si-nc systems prepared by SiO x layer deposition, this result demonstrates the presence of α-Si in high excess Si implanted Si-nc systems

  5. Validation of calculated tissue maximum ratio obtained from measured percentage depth dose (PPD) data for high energy photon beam ( 6 MV and 15 MV)

    International Nuclear Information System (INIS)

    Osei, J.E.

    2014-07-01

    During external beam radiotherapy treatments, high doses are delivered to the cancerous cell. Accuracy and precision of dose delivery are primary requirements for effective and efficiency in treatment. This leads to the consideration of treatment parameters such as percentage depth dose (PDD), tissue air ratio (TAR) and tissue phantom ratio (TPR), which show the dose distribution in the patient. Nevertheless, tissue air ratio (TAR) for treatment time calculation, calls for the need to measure in-air-dose rate. For lower energies, measurement is not a problem but for higher energies, in-air measurement is not attainable due to the large build-up material required for the measurement. Tissue maximum ratio (TMR) is the quantity required to replace tissue air ratio (TAR) for high energy photon beam. It is known that tissue maximum ratio (TMR) is an important dosimetric function in radiotherapy treatment. As the calculation methods used to determine tissue maximum ratio (TMR) from percentage depth dose (PDD) were derived by considering the differences between TMR and PDD such as geometry and field size, where phantom scatter or peak scatter factors are used to correct dosimetric variation due to field size difference. The purpose of this study is to examine the accuracy of calculated tissue maximum ratio (TMR) data with measured TMR values for 6 MV and 15 MV photon beam at Sweden Ghana Medical Centre. With the help of the Blue motorize water phantom and the Omni pro-Accept software, Pdd values from which TMRs are calculated were measured at 100 cm source-to-surface distance (SSD) for various square field sizes from 5x5 cm to 40x40 cm and depth of 1.5 cm to 25 cm for 6 MV and 15 MV x-ray beam. With the same field sizes, depths and energies, the TMR values were measured. The validity of the calculated data was determined by making a comparison with values measured experimentally at some selected field sizes and depths. The results show that; the reference depth of maximum

  6. Mobile Probing and Probes

    DEFF Research Database (Denmark)

    Duvaa, Uffe; Ørngreen, Rikke; Weinkouff Mathiasen, Anne-Gitte

    2013-01-01

    Mobile probing is a method, developed for learning about digital work situations, as an approach to discover new grounds. The method can be used when there is a need to know more about users and their work with certain tasks, but where users at the same time are distributed (in time and space......). Mobile probing was inspired by the cultural probe method, and was influenced by qualitative interview and inquiry approaches. The method has been used in two subsequent projects, involving school children (young adults at 15-17 years old) and employees (adults) in a consultancy company. Findings point...... to mobile probing being a flexible method for uncovering the unknowns, as a way of getting rich data to the analysis and design phases. On the other hand it is difficult to engage users to give in depth explanations, which seem easier in synchronous dialogs (whether online or face2face). The development...

  7. Mobile Probing and Probes

    DEFF Research Database (Denmark)

    Duvaa, Uffe; Ørngreen, Rikke; Weinkouff, Anne-Gitte

    2012-01-01

    Mobile probing is a method, which has been developed for learning about digital work situations, as an approach to discover new grounds. The method can be used when there is a need to know more about users and their work with certain tasks, but where users at the same time are distributed (in time...... and space). Mobile probing was inspired by the cultural probe method, and was influenced by qualitative interview and inquiry approaches. The method has been used in two subsequent projects, involving school children (young adults at 15-17 years old) and employees (adults) in a consultancy company. Findings...... point to mobile probing being a flexible method for uncovering the unknowns, as a way of getting rich data to the analysis and design phases. On the other hand it is difficult to engage users to give in depth explanations, which seem easier in synchronous dialogs (whether online or face2face...

  8. Eddy-current probe design

    International Nuclear Information System (INIS)

    Kincaid, T.G.; McCary, R.O.

    1983-01-01

    This paper describes theoretical and experimental work directed toward finding the optimum probe dimensions and operating frequency for eddy current detection of half-penny surface cracks in nonmagnetic conducting materials. The study applies to probes which excite an approximately uniform spatial field over the length of the crack at the surface of the material. In practical terms, this means that the probe is not smaller than the crack length in any of its critical dimensions. The optimization of a simple coil probe is first analyzed in detail. It is shown that signal-to-noise ratio and lift-off discrimination are maximized by a pancake coil with mean radius not greater than the crack length, operated at a frequency which gives a skin depth equal to the crack depth. The results obtained for the simple coil are then used as a basis for discussion of the design of coils with ferrite cores and shields, and for the design of recording head type probes

  9. The Galileo Probe: How it Has Changed Our Understanding of Jupiter

    Science.gov (United States)

    Young, Richard E.

    2003-01-01

    similarly affected but attained their deep equilibrium mixing ratios before the maximum depth sampled by the probe. Processes that might be capable of producing such effects on the condensibles are still under investigation. Measured isotopic ratios of noble gases and other heavy elements are solar, and (D + (Sup 3)He)/H is the same to within measurement uncertainties as in the local interstellar medium. No thick clouds were detected, and in particular no significant water cloud, but the PES location clearly affected the probe measurements of clouds. In fact, the probe data must be understood in the context of the location of the PES, which was within what is termed a 5 micron hot spot, a local clearing in the clouds that is bright near the 5 microns spectral region. The thermal structure at the PES was determined from approximately 1000 km above the 1 bar pressure level (10(exp -9 bars)) to 132 km 1 bar (22bars). The probe showed the atmosphere to have a generally sub-adiabatic temperature gradient (static stability) of = 0.1 K/km to as deep as the probe made measurements. In the upper atmosphere the probe derived a maximum positive vertical temperature gradient of approximately 5 K/km, and maximum temperature of = 900 K. The energy sources producing the warm upper atmosphere have yet to be completely identified. At first glance, Doppler tracking of the probe indicates that the long observed cloud level zonal winds extend to levels at least as deep as the probe made measurements. Zonal wind increases from = 80 m/s at pressures less than a bar to about 180 m/s near 5 bars, and remains approximately constant with depth thereafter. However, there is a question as to whether the winds measured from probe tracking are representative of the general wind field, or are considerably influenced by localized winds associated with the PES.

  10. A very accurate method for sentinel lymph node investigation: Gamma detecting probe associated with SPECT examination for depth

    International Nuclear Information System (INIS)

    Ascoli, G.; Cinti, P.; Nonni, M.; Rossi, B.

    2002-01-01

    Aim: aim of this study is to magnify the lymphoscintigraphy examination by gamma probe with SPECT acquisition for very accurate detection of depth of axilla node in patients affected by melanoma. Methods: according to physiological peculiarities the lymphatic system plays a very important role and represents the most important barrier to neoplastic cells spreading. The 'sentinel node' is the first lymph node draining the affected area. The tendency for surgery is a 'preventive' axillary dissection, even in presence of a clinically negative examination. In fact a high percentage of clinically negative lymph node shows a positive histology (presence of metastatic cells). The nuclear medicine method for researching 'sentinel node' is represented by a regional lymphoscintigraphy with normal gamma camera with a large field of view followed by examination with gamma detecting probe and, in following day, controlled in operating room to confirm the presence of the node early identified. We have completed this protocol with SPECT examination of affected axilla by use of injected laboratory capillary around axilla to perform an exact investigation of node depth. Discussion: Our experience in 150 cases in 18 months shows 100% of axilla 'sentinel node' detection, 25 cases with positive histologic examination and subsequently axillary dissection. Conclusions: In conclusion the scintigraphic examination with lymphoscintigraphy represents a good tool for management of patient with melanoma and the use of ''targeting' with collimated SPECT represent a very aid for the surgeon in reduction time for detection and dissection of lymph node, with high reduction of anesthesia duration

  11. Depth-profiling using X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Pijolat, M.; Hollinger, G.

    1980-12-01

    The possibilities of X-ray photoelectron spectroscopy (or ESCA) for depth-profiling into shallow depths (approximately 10-100 A) have been studied. The method of ion-sputtering removal has first been investigated in order to improve its depth-resolution (approximately 50-150 A). A procedure which eliminates the effects due to the resolution function of the instrumental probe (analysed depth approximately 50 A) has been settled; but it is not yet sufficient, and the sputter - broadening due to the ion-induced damages must be taken into account (broadening function approximately 50 A for approximately 150 A removal). Because of serious difficulties in estimating the broadening function an alternative is to develop non destructive methods, so a new method based on the dependence of the analysed depth with the electron emission angle is presented. The extraction of the concentration profile from angular distribution experiments is achieved, in the framework of a flat-layer model, by minimizing the difference between theoretical and experimental relative intensities. The applicability and limitations of the method are discussed on the basis of computer simulation results. The depth probed is of the order of 3 lambda (lambda being the value of the inelastic mean free path, typically 10-20 A) and the depth-resolution is of the order of lambda/3 [fr

  12. Influence of spatial and temporal spot distribution on the ocular surface quality and maximum ablation depth after photoablation with a 1050 Hz excimer laser system.

    Science.gov (United States)

    Mrochen, Michael; Schelling, Urs; Wuellner, Christian; Donitzky, Christof

    2009-02-01

    To investigate the effect of temporal and spatial distributions of laser spots (scan sequences) on the corneal surface quality after ablation and the maximum ablation of a given refractive correction after photoablation with a high-repetition-rate scanning-spot laser. IROC AG, Zurich, Switzerland, and WaveLight AG, Erlangen, Germany. Bovine corneas and poly(methyl methacrylate) (PMMA) plates were photoablated using a 1050 Hz excimer laser prototype for corneal laser surgery. Four temporal and spatial spot distributions (scan sequences) with different temporal overlapping factors were created for 3 myopic, 3 hyperopic, and 3 phototherapeutic keratectomy ablation profiles. Surface quality and maximum ablation depth were measured using a surface profiling system. The surface quality factor increased (rough surfaces) as the amount of temporal overlapping in the scan sequence and the amount of correction increased. The rise in surface quality factor was less for bovine corneas than for PMMA. The scan sequence might cause systematic substructures at the surface of the ablated material depending on the overlapping factor. The maximum ablation varied within the scan sequence. The temporal and spatial distribution of the laser spots (scan sequence) during a corneal laser procedure affected the surface quality and maximum ablation depth of the ablation profile. Corneal laser surgery could theoretically benefit from smaller spot sizes and higher repetition rates. The temporal and spatial spot distributions are relevant to achieving these aims.

  13. A new probe for in situ TDR moisture measurement

    Energy Technology Data Exchange (ETDEWEB)

    Yokuda, E. (EG and G Idaho, Inc., Idaho Falls, ID (United States)); Smith, R. (Sonsub Services, Inc., Houston, TX (United States))

    1993-01-01

    This paper explains the development of a new Time Domain Reflectometry (TDR) probe which can be inserted through waste and soil to a depth of 14 feet with minimal labor and minimal soil disturbance. TDR has been used for 10 years as a method for measuring soil moisture contents. Conventional TDR probes are 30 centimeters long and therefore are difficult to insert at depths below a few feet. Recently, a probe has been developed which can be inserted to depths of 14 feet with the use of a vibratory drill. Quality objectives for the instrument, preliminary data, and suggestions for future developments are presented.

  14. A new probe for in situ TDR moisture measurement

    International Nuclear Information System (INIS)

    Yokuda, E.; Smith, R.

    1993-01-01

    This paper explains the development of a new Time Domain Reflectometry (TDR) probe which can be inserted through waste and soil to a depth of 14 feet with minimal labor and minimal soil disturbance. TDR has been used for 10 years as a method for measuring soil moisture contents. Conventional TDR probes are 30 centimeters long and therefore are difficult to insert at depths below a few feet. Recently, a probe has been developed which can be inserted to depths of 14 feet with the use of a vibratory drill. Quality objectives for the instrument, preliminary data, and suggestions for future developments are presented

  15. A new probe for in situ TDR moisture measurement

    Energy Technology Data Exchange (ETDEWEB)

    Yokuda, E. [EG and G Idaho, Inc., Idaho Falls, ID (United States); Smith, R. [Sonsub Services, Inc., Houston, TX (United States)

    1993-05-01

    This paper explains the development of a new Time Domain Reflectometry (TDR) probe which can be inserted through waste and soil to a depth of 14 feet with minimal labor and minimal soil disturbance. TDR has been used for 10 years as a method for measuring soil moisture contents. Conventional TDR probes are 30 centimeters long and therefore are difficult to insert at depths below a few feet. Recently, a probe has been developed which can be inserted to depths of 14 feet with the use of a vibratory drill. Quality objectives for the instrument, preliminary data, and suggestions for future developments are presented.

  16. Depth-selective X-ray absorption spectroscopy by detection of energy-loss Auger electrons

    Energy Technology Data Exchange (ETDEWEB)

    Isomura, Noritake, E-mail: isomura@mosk.tytlabs.co.jp [Toyota Central R& D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192 (Japan); Soejima, Narumasa; Iwasaki, Shiro [Toyota Central R& D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192 (Japan); Nomoto, Toyokazu; Murai, Takaaki [Aichi Synchrotron Radiation Center (AichiSR), 250-3 Minamiyamaguchi-cho, Seto, Aichi 489-0965 (Japan); Kimoto, Yasuji [Toyota Central R& D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192 (Japan)

    2015-11-15

    Graphical abstract: - Highlights: • A unique XAS method is proposed for depth profiling of chemical states. • PEY mode detecting energy-loss electrons enables a variation in the probe depth. • Si K-edge XAS spectra of the Si{sub 3}N{sub 4}/SiO{sub 2}/Si multilayer films have been investigated. • Deeper information was obtained in the spectra measured at larger energy loss. • Probe depth could be changed by the selection of the energy of detected electrons. - Abstract: A unique X-ray absorption spectroscopy (XAS) method is proposed for depth profiling of chemical states in material surfaces. Partial electron yield mode detecting energy-loss Auger electrons, called the inelastic electron yield (IEY) mode, enables a variation in the probe depth. As an example, Si K-edge XAS spectra for a well-defined multilayer sample (Si{sub 3}N{sub 4}/SiO{sub 2}/Si) have been investigated using this method at various kinetic energies. We found that the peaks assigned to the layers from the top layer to the substrate appeared in the spectra in the order of increasing energy loss relative to the Auger electrons. Thus, the probe depth can be changed by the selection of the kinetic energy of the energy loss electrons in IEY-XAS.

  17. Depth-selective X-ray absorption spectroscopy by detection of energy-loss Auger electrons

    International Nuclear Information System (INIS)

    Isomura, Noritake; Soejima, Narumasa; Iwasaki, Shiro; Nomoto, Toyokazu; Murai, Takaaki; Kimoto, Yasuji

    2015-01-01

    Graphical abstract: - Highlights: • A unique XAS method is proposed for depth profiling of chemical states. • PEY mode detecting energy-loss electrons enables a variation in the probe depth. • Si K-edge XAS spectra of the Si_3N_4/SiO_2/Si multilayer films have been investigated. • Deeper information was obtained in the spectra measured at larger energy loss. • Probe depth could be changed by the selection of the energy of detected electrons. - Abstract: A unique X-ray absorption spectroscopy (XAS) method is proposed for depth profiling of chemical states in material surfaces. Partial electron yield mode detecting energy-loss Auger electrons, called the inelastic electron yield (IEY) mode, enables a variation in the probe depth. As an example, Si K-edge XAS spectra for a well-defined multilayer sample (Si_3N_4/SiO_2/Si) have been investigated using this method at various kinetic energies. We found that the peaks assigned to the layers from the top layer to the substrate appeared in the spectra in the order of increasing energy loss relative to the Auger electrons. Thus, the probe depth can be changed by the selection of the kinetic energy of the energy loss electrons in IEY-XAS.

  18. Proposing a Novel, Three-level Definition of Periodontitis 
using Probing Depth, Clinical Attachment Loss and Bleeding on Probing: Analysis of a Rural Chinese Population.

    Science.gov (United States)

    Pei, Xi Yan; He, Lu; Ouyang, Xiang Ying

    To propose a novel, three-level (severe, moderate, mild) case definition using probing depth (PD), clinical attachment loss (CAL) and bleeding on probing (BOP) for epidemiologic studies on periodontitis. Case definitions (DEF) 1-30 with PD, CAL and BOP were made. Based on data from epidemiologic research in Chengde (Hebei Province, China) in 1992, prevalence of periodontitis by DEF1-30 was calculated and compared with a reference (definitions by Centers for Disease Control and Prevention/American Academy of Periodontology in 2012). Sensitivity, specificity, Youden Index, Cohen's kappa coefficient (CKC) and the area under the receiver operator characteristic curve (AUC) were calculated for the definitions selected. DEF1 and DEF18 for periodontitis, DEF2, DEF3, DEF19 for moderate and severe periodontitis, and DEF5, DEF13, DEF14, DEF21 and DEF25 for severe periodontitis, which were similar for estimation of periodontitis prevalence compared with the reference, were selected. DEF18 for periodontitis, DEF19 for moderate and severe periodontitis, and DEF5 for severe periodontitis were selected because they showed higher values for the Youden Index, CKC and AUC, and formed a three-level definition. A novel three-level case classification of periodontitis using three parameters of PD, CAL and BOP was proposed. The estimated periodontitis prevalence according to the novel proposed definition is close to the prevalence according to the CDC/AAP definition.

  19. Detection and depth determination of corrosion defects in embedded bolts using ultrasonic testing technique

    International Nuclear Information System (INIS)

    Lin, Shan; Fukutomi, Hiroyuki; Yuya, Hideki; Ito, Keisuke

    2011-01-01

    A great number of anchor bolts are used to fix various components to concrete foundation in thermal and nuclear power plants. As aging power plants degrade, it is feared that defects resulted from corrosion may occur underground. In this paper, a measurement method utilizing the phased array technique is developed to detect such defects. Measurement results show that this method can detect local and circumferential corrosion defects introduced artificially, but defect echo position appears to be farther away from the bolt head than is actually the case. A finite element simulation of wave propagation shows that longitudinal waves excited by a phased array probe are mode converted and reflected at the defect and at bolt wall, which results in the position of the defect echo appearing to be farther away than the defect actually is. Moreover, an approach for determining the depth of defects using measurement results is also proposed based on numerical results. The depths determined by the proposed approach agree with the actual depths with a maximum error of 1.8 mm and a RMSE of 1.06 mm. (author)

  20. Maximizing Reading Narrative Text Ability by Probing Prompting Learning Technique

    Directory of Open Access Journals (Sweden)

    Wiwied Pratiwi

    2017-12-01

    Full Text Available The objective of this research was to know whether Probing Prompting Learning Technique can be used to get the maximum effect of students’ reading narrative ability in teaching and learning process. This research was applied collaborative action reEsearch, this research was done in two cycle. The subject of this research was 23 students at tenth grade of SMA Kartikatama Metro. The result of the research showed that the Probing Prompting Learning Technique is useful and effective to help students get maximum effect of their reading. Based on the results of the questionnaire obtained an average percentage of 95%, it indicated that application of Probing Prompting Learning Technique in teaching l reading was appropriately applied. In short that students’ responses toward Probing Prompting Learning Technique in teaching reading was positive. In conclusion, Probing Prompting Learning Technique can get maximum effect of students’ reading ability. In relation to the result of the reserach, some suggestion are offered to english teacher, that  the use of Probing Prompting learning Technique in teaching reading will get the maximum effect of students’ reading abilty.

  1. Determination of degree of compacting and of moisture content by radiometric probes

    International Nuclear Information System (INIS)

    Martinec, J.; Paul, P.

    1977-01-01

    A survey is given of radiometric probes used for measuring bulk density and moisture content. Surface probes are used in depths of up to 20 cm with an accuracy of 10%, drive-in probes are used to depths of up to 50 cm with a 4% error, depth probes are used for measuring in depths of 30 to 50 cm with an accuracy of roughly 5% and bulk density in depths of 10 to 150 cm may be measured with an accuracy of 2% using a lysimeter. Changes in the bulk density and soil moisture of the subsoil of an airport runway were studied radiometrically in dependence on time and depth. The dependence is represented graphically. The results of radiometric measurements were compared with the conventional method using a lysimeter probe; the comparison showed that the results were lower by about 7% for the moisture content and higher by about 8% for the bulk density. Radiometric measurements for determining bulk density and soil moisture are advantageous in that they allow the measurement of a great number of sites without any major disturbance of the measured material and results are available immediately on measurement. The economic effect is significant in a large number of measurements carried out on a surface having the same chemical composition and similar grain size which does not necessitate calibration of the instruments to be made more than once a week. The NZK-201 probe by Tesla does not provide sufficiently accurate information on the moisture and density of the earths probed

  2. Methodical comparison of neutron depth probes and long-term soil moisture measurements on loess, sandy loess, and boulder clay

    International Nuclear Information System (INIS)

    Neue, H.U.

    1980-01-01

    Three measuring instruments were tested: 0.05 mCi Cf-252, 100 mCi Am-241/Be, 500 mCi Am-241/Be. The advantages - measurement in undisturbed soil profiles, large depths of measurement, reproducibility of measurements in the same place over several years - and the disadvantages - radiation protection, resolution, variations of measured volume in dependence of moisture, background influences etc. - have been critically checked by experiment. In addition, annual soil moisture curves have been measured over two years by parallel use of the free probes on a loess, sandy loess, and boulder clay site. The results were compared and discussed with a view to the soil water dynamics of these sites. (orig./HP) [de

  3. The performance and radiation exposure of some neutron probes in measuring the water content of the topsoil layer

    International Nuclear Information System (INIS)

    Arslan, A.; Razzouk, A.K.; Al-Ain, F.

    1997-01-01

    The use of neutron scattering technique for determining the soil surface water content is not popular due to the radiation escaping from the soil surface and the large errors in measurement. To compare the radiation exposure and the performance of different techniques statistically, 3 sites were selected. Five different neutron probe models and different adaptors were used with the depth probes. Exposure to neutrons and γ radiations, at various distances from the probes, were determined. In situ calibration curves were determined using different models of depth probes with a Solo surface reflector block, CPN surface adaptor, and different numbers of plastic Teflon parallelepiped, as well as surface Troxler 3401-B probes. Depth neutron probe readings increased with increasing number of Teflon plastic blocks deposited on the soil surface. The intercept of the straight line regression analysis of CR (count ratio, surface count over standard count) v. percentage water content on a volume basis decreased with increasing number of blocks deposited on the soil surface at all sites. The determination coefficient values of any depth probe with a Solo surface reflector or a block of 4-8 cm thickness were higher than those of a Troxler 3401-B surface probe or CPN 503 depth probe with its surface adaptor. The least exposure to radiation was with a depth probe with surface reflectors. This study proves the possibility of measuring the moisture content of the soil surface by using a depth neutron probe with a block laid on the surface, without danger of receiving the threshold dose of radiation. (authors)

  4. A portable storage maximum thermometer

    International Nuclear Information System (INIS)

    Fayart, Gerard.

    1976-01-01

    A clinical thermometer storing the voltage corresponding to the maximum temperature in an analog memory is described. End of the measurement is shown by a lamp switch out. The measurement time is shortened by means of a low thermal inertia platinum probe. This portable thermometer is fitted with cell test and calibration system [fr

  5. Intrauterine photoacoustic and ultrasound imaging probe

    Science.gov (United States)

    Miranda, Christopher; Barkley, Joel; Smith, Barbara S.

    2018-04-01

    Intrauterine photoacoustic and ultrasound imaging are probe-based imaging modalities with translational potential for use in detecting endometrial diseases. This deep-tissue imaging probe design allows for the retrofitting of commercially available endometrial sampling curettes. The imaging probe presented here has a 2.92-mm diameter and approximate length of 26 cm, which allows for entry into the human endometrial cavity, making it possible to use photoacoustic imaging and high-resolution ultrasound to characterize the uterus. We demonstrate the imaging probes' ability to provide structural information of an excised pig uterus using ultrasound imaging and detect photoacoustic signals at a radial depth of 1 cm.

  6. Intercomparison On Depth Dose Measurement

    International Nuclear Information System (INIS)

    Rohmah, N; Akhadi, M

    1996-01-01

    Intercomparation on personal dose evaluation system has been carried out between CSRSR-NAEA of Indonesia toward Standard Laboratory of JAERI (Japan) and ARL (Australia). The intercomparison was in 10 amm depth dose measurement , Hp (10), from the intercomparison result could be stated that personal depth dose measurement conducted by CSRSR was sufficiently good. Deviation of dose measurement result using personal dosemeter of TLD BG-1 type which were used by CSRSR in the intercomparison and routine photon personal dose monitoring was still in internationally agreed limit. Maximum deviation of reported doses by CSRSR compared to delivered doses for dosemeter irradiation by JAERI was -10.0 percent and by ARL was +29 percent. Maximum deviation permitted in personal dose monitoring is ± 50 percent

  7. Dual-Frequency Bistatic Radar Probing of Mars: Potential and Pitfalls for Depth Sounding at Centimeter Wavelengths

    Science.gov (United States)

    Simpson, R. A.; Tyler, G. L.; Paetzold, M.; Haeusler, B.; Asmar, S. W.

    2009-12-01

    Early spacecraft-to-Earth bistatic radar (BSR) probing of Mars' surface emphasized measurement of rms surface slopes on scales of centimeters to a few meters, information of particular interest to the design and deployment of landers and rovers. Shorter wavelengths yielded higher values, consistent with fractal models in which surface texture becomes rougher as the measuring instrument senses more detail. Although Mars Express (MEX) has found the smoothest extraterrestrial solid surface yet observed by radar (0.17 deg rms in the north polar region), its antenna pattern typically illuminates only part of the scattering surface, making rms slope determination difficult. With careful calibration, however, the ratio of echo power in its two orthogonal polarizations can be used to infer the dielectric constant of the surface material from the Fresnel reflection coefficients. Early results showed larger dielectric constant at 12.6 cm than 3.6 cm, consistent with materials which become more densely packed at depth; as the data collection continued, regional variations became apparent. More puzzling, are cases in which the derived dielectric constant is 30 percent larger at the shorter wavelength, suggesting a centimeter of crust (invisible at 12.6 cm wavelength) overlying less dense regolith below. Duricrust layers have been inferred in some of these areas from thermal measurements; and a layer of gravel, stripped of finer particles, could produce similar effects. Earth-to-spacecraft BSR could improve measurement sensitivity by factors of 100-1000; spacecraft-to-spacecraft experiments could improve surface coverage. All three configurations, including the conventional 'downlink' experiments now being conducted, can provide basic information on surface structure to depths of a few centimeters.

  8. Extended depth of field imaging through multicore optical fibers.

    Science.gov (United States)

    Orth, Antony; Ploschner, Martin; Maksymov, Ivan S; Gibson, Brant C

    2018-03-05

    Compact microendoscopes use multicore optical fibers (MOFs) to visualize hard-to-reach regions of the body. These devices typically have a large numerical aperture (NA) and are fixed-focus, leading to blurry images from a shallow depth of field with little focus control. In this work, we demonstrate a method to digitally adjust the collection aperture and therefore extend the depth of field of lensless MOF imaging probes. We show that the depth of field can be more than doubled for certain spatial frequencies, and observe a resolution enhancement of up to 78% at a distance of 50μm from the MOF facet. Our technique enables imaging of complex 3D objects at a comparable working distance to lensed MOFs, but without the requirement of lenses, scan units or transmission matrix calibration. Our approach is implemented in post processing and may be used to improve contrast in any microendoscopic probe utilizing a MOF and incoherent light.

  9. Non-destructive microstructural analysis with depth resolution

    Energy Technology Data Exchange (ETDEWEB)

    Zolotoyabko, E. E-mail: zloto@tx.technion.ac.il; Quintana, J.P

    2003-01-01

    A depth-sensitive X-ray diffraction technique has been developed with the aim of studying microstructural modifications in inhomogeneous polycrystalline materials. In that method, diffraction profiles are measured at different X-ray energies varied by small steps. X-rays at higher energies probe deeper layers of material. Depth-resolved structural information is retrieved by comparing energy-dependent diffraction profiles. The method provides non-destructive depth profiling of the preferred orientation, grain size, microstrain fluctuations and residual strains. This technique is applied to the characterization of seashells. Similarly, energy-variable X-ray diffraction can be used for the non-destructive characterization of different laminated structures and composite materials.

  10. Intrauterine photoacoustic and ultrasound imaging probe.

    Science.gov (United States)

    Miranda, Christopher; Barkley, Joel; Smith, Barbara

    2018-04-01

    Intrauterine photoacoustic and ultrasound imaging are probe-based imaging modalities with translational potential for use in detecting endometrial diseases. This deep-tissue imaging probe design allows for the retrofitting of commercially available endometrial sampling curettes. The imaging probe presented here has a 2.92-mm diameter and approximate length of 26 cm, which allows for entry into the human endometrial cavity, making it possible to use photoacoustic imaging and high-resolution ultrasound to characterize the uterus. We demonstrate the imaging probes' ability to provide structural information of an excised pig uterus using ultrasound imaging and detect photoacoustic signals at a radial depth of 1 cm. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  11. ACCURACY ANALYSIS OF KINECT DEPTH DATA

    Directory of Open Access Journals (Sweden)

    K. Khoshelham

    2012-09-01

    Full Text Available This paper presents an investigation of the geometric quality of depth data obtained by the Kinect sensor. Based on the mathematical model of depth measurement by the sensor a theoretical error analysis is presented, which provides an insight into the factors influencing the accuracy of the data. Experimental results show that the random error of depth measurement increases with increasing distance to the sensor, and ranges from a few millimetres up to about 4 cm at the maximum range of the sensor. The accuracy of the data is also found to be influenced by the low resolution of the depth measurements.

  12. Multi-point probe for testing electrical properties and a method of producing a multi-point probe

    DEFF Research Database (Denmark)

    2011-01-01

    A multi-point probe for testing electrical properties of a number of specific locations of a test sample comprises a supporting body defining a first surface, a first multitude of conductive probe arms (101-101'''), each of the probe arms defining a proximal end and a distal end. The probe arms...... of contact with the supporting body, and a maximum thickness perpendicular to its perpendicular bisector and its line of contact with the supporting body. Each of the probe arms has a specific area or point of contact (111-111''') at its distal end for contacting a specific location among the number...... of specific locations of the test sample. At least one of the probe arms has an extension defining a pointing distal end providing its specific area or point of contact located offset relative to its perpendicular bisector....

  13. Corrosion pit depth extreme value prediction from limited inspection data

    International Nuclear Information System (INIS)

    Najjar, D.; Bigerelle, M.; Iost, A.; Bourdeau, L.; Guillou, D.

    2004-01-01

    Passive alloys like stainless steels are prone to localized corrosion in chlorides containing environments. The greater the depth of the localized corrosion phenomenon, the more dramatic the related damage that can lead to a structure weakening by fast perforation. In practical situations, because measurements are time consuming and expensive, the challenge is usually to predict the maximum pit depth that could be found in a large scale installation from the processing of a limited inspection data. As far as the parent distribution of pit depths is assumed to be of exponential type, the most successful method was found in the application of the statistical extreme-value analysis developed by Gumbel. This study aims to present a new and alternative methodology to the Gumbel approach with a view towards accurately estimating the maximum pit depth observed on a ferritic stainless steel AISI 409 subjected to an accelerated corrosion test (ECC1) used in automotive industry. This methodology consists in characterising and modelling both the morphology of pits and the statistical distribution of their depths from a limited inspection dataset. The heart of the data processing is based on the combination of two recent statistical methods that avoid making any choice about the type of the theoretical underlying parent distribution of pit depths: the Generalized Lambda Distribution (GLD) is used to model the distribution of pit depths and the Bootstrap technique to determine a confidence interval on the maximum pit depth. (authors)

  14. Depth of maximum of air-shower profiles at the Pierre Auger Observatory. I. Measurements at energies above 10.sup.17.8./sup.  eV

    Czech Academy of Sciences Publication Activity Database

    Aab, A.; Abreu, P.; Aglietta, M.; Boháčová, Martina; Chudoba, Jiří; Ebr, Jan; Mandát, Dušan; Nečesal, Petr; Palatka, Miroslav; Pech, Miroslav; Prouza, Michael; Řídký, Jan; Schovánek, Petr; Trávníček, Petr; Vícha, Jakub

    2014-01-01

    Roč. 90, č. 12 (2014), "122005-1"-"122005-25" ISSN 1550-7998 R&D Projects: GA MŠk(CZ) 7AMB14AR005; GA MŠk(CZ) LG13007; GA ČR(CZ) GA14-17501S Institutional support: RVO:68378271 Keywords : astroparticle physics * Pierre Auger Observatory * cosmic rays * air showers * depth of maximum * Xmax Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 4.643, year: 2014

  15. A comparison of different neutron probes calibration method for the soil surface and their radiation effect on the users

    Energy Technology Data Exchange (ETDEWEB)

    Arslan, A; Razzouk, A K; Al-Ain, F [Atomic Energy commission , Damascus (Syrian Arab Republic). Dept of Radiation Agriculture

    1996-08-01

    In situ calibration curves were installed for the soil surface using different models of depth neutron probes and different adaptors. depth beutron probe readings increased with increasing the number of teflon plastic blocks deposited on the soil surface. The intercept of the straight line regression analysis decreased with increasing of teflon plastics blocks deposited on the soil surface in all sites. The least exposure was with depth probe with surface reflectors. This study proves the possibility of measuring the moisture content of the soil surface by using a depth probe with a block laid on the surface, without a danger of receiving the thresgold of radiation dose. (author). 10 Refs., 2 Figs., 8 Tabs.

  16. Quantitative operando visualization of the energy band depth profile in solar cells.

    Science.gov (United States)

    Chen, Qi; Mao, Lin; Li, Yaowen; Kong, Tao; Wu, Na; Ma, Changqi; Bai, Sai; Jin, Yizheng; Wu, Dan; Lu, Wei; Wang, Bing; Chen, Liwei

    2015-07-13

    The energy band alignment in solar cell devices is critically important because it largely governs elementary photovoltaic processes, such as the generation, separation, transport, recombination and collection of charge carriers. Despite the expenditure of considerable effort, the measurement of energy band depth profiles across multiple layers has been extremely challenging, especially for operando devices. Here we present direct visualization of the surface potential depth profile over the cross-sections of operando organic photovoltaic devices using scanning Kelvin probe microscopy. The convolution effect due to finite tip size and cantilever beam crosstalk has previously prohibited quantitative interpretation of scanning Kelvin probe microscopy-measured surface potential depth profiles. We develop a bias voltage-compensation method to address this critical problem and obtain quantitatively accurate measurements of the open-circuit voltage, built-in potential and electrode potential difference.

  17. Maximum likelihood positioning for gamma-ray imaging detectors with depth of interaction measurement

    International Nuclear Information System (INIS)

    Lerche, Ch.W.; Ros, A.; Monzo, J.M.; Aliaga, R.J.; Ferrando, N.; Martinez, J.D.; Herrero, V.; Esteve, R.; Gadea, R.; Colom, R.J.; Toledo, J.; Mateo, F.; Sebastia, A.; Sanchez, F.; Benlloch, J.M.

    2009-01-01

    The center of gravity algorithm leads to strong artifacts for gamma-ray imaging detectors that are based on monolithic scintillation crystals and position sensitive photo-detectors. This is a consequence of using the centroids as position estimates. The fact that charge division circuits can also be used to compute the standard deviation of the scintillation light distribution opens a way out of this drawback. We studied the feasibility of maximum likelihood estimation for computing the true gamma-ray photo-conversion position from the centroids and the standard deviation of the light distribution. The method was evaluated on a test detector that consists of the position sensitive photomultiplier tube H8500 and a monolithic LSO crystal (42mmx42mmx10mm). Spatial resolution was measured for the centroids and the maximum likelihood estimates. The results suggest that the maximum likelihood positioning is feasible and partially removes the strong artifacts of the center of gravity algorithm.

  18. Maximum likelihood positioning for gamma-ray imaging detectors with depth of interaction measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lerche, Ch.W. [Grupo de Sistemas Digitales, ITACA, Universidad Politecnica de Valencia, 46022 Valencia (Spain)], E-mail: lerche@ific.uv.es; Ros, A. [Grupo de Fisica Medica Nuclear, IFIC, Universidad de Valencia-Consejo Superior de Investigaciones Cientificas, 46980 Paterna (Spain); Monzo, J.M.; Aliaga, R.J.; Ferrando, N.; Martinez, J.D.; Herrero, V.; Esteve, R.; Gadea, R.; Colom, R.J.; Toledo, J.; Mateo, F.; Sebastia, A. [Grupo de Sistemas Digitales, ITACA, Universidad Politecnica de Valencia, 46022 Valencia (Spain); Sanchez, F.; Benlloch, J.M. [Grupo de Fisica Medica Nuclear, IFIC, Universidad de Valencia-Consejo Superior de Investigaciones Cientificas, 46980 Paterna (Spain)

    2009-06-01

    The center of gravity algorithm leads to strong artifacts for gamma-ray imaging detectors that are based on monolithic scintillation crystals and position sensitive photo-detectors. This is a consequence of using the centroids as position estimates. The fact that charge division circuits can also be used to compute the standard deviation of the scintillation light distribution opens a way out of this drawback. We studied the feasibility of maximum likelihood estimation for computing the true gamma-ray photo-conversion position from the centroids and the standard deviation of the light distribution. The method was evaluated on a test detector that consists of the position sensitive photomultiplier tube H8500 and a monolithic LSO crystal (42mmx42mmx10mm). Spatial resolution was measured for the centroids and the maximum likelihood estimates. The results suggest that the maximum likelihood positioning is feasible and partially removes the strong artifacts of the center of gravity algorithm.

  19. High bit depth infrared image compression via low bit depth codecs

    Science.gov (United States)

    Belyaev, Evgeny; Mantel, Claire; Forchhammer, Søren

    2017-08-01

    Future infrared remote sensing systems, such as monitoring of the Earth's environment by satellites, infrastructure inspection by unmanned airborne vehicles etc., will require 16 bit depth infrared images to be compressed and stored or transmitted for further analysis. Such systems are equipped with low power embedded platforms where image or video data is compressed by a hardware block called the video processing unit (VPU). However, in many cases using two 8-bit VPUs can provide advantages compared with using higher bit depth image compression directly. We propose to compress 16 bit depth images via 8 bit depth codecs in the following way. First, an input 16 bit depth image is mapped into 8 bit depth images, e.g., the first image contains only the most significant bytes (MSB image) and the second one contains only the least significant bytes (LSB image). Then each image is compressed by an image or video codec with 8 bits per pixel input format. We analyze how the compression parameters for both MSB and LSB images should be chosen to provide the maximum objective quality for a given compression ratio. Finally, we apply the proposed infrared image compression method utilizing JPEG and H.264/AVC codecs, which are usually available in efficient implementations, and compare their rate-distortion performance with JPEG2000, JPEG-XT and H.265/HEVC codecs supporting direct compression of infrared images in 16 bit depth format. A preliminary result shows that two 8 bit H.264/AVC codecs can achieve similar result as 16 bit HEVC codec.

  20. The maximum significant wave height in the Southern North Sea

    NARCIS (Netherlands)

    Bouws, E.; Tolman, H.L.; Holthuijsen, L.H.; Eldeberky, Y.; Booij, N.; Ferier, P.

    1995-01-01

    The maximum possible wave conditions along the Dutch coast, which seem to be dominated by the limited water depth, have been estimated in the present study with numerical simulations. Discussions with meteorologists suggest that the maximum possible sustained wind speed in North Sea conditions is

  1. Multisensor Capacitance Probes for Simultaneously Monitoring Rice Field Soil-Water- Crop-Ambient Conditions.

    Science.gov (United States)

    Brinkhoff, James; Hornbuckle, John; Dowling, Thomas

    2017-12-26

    Multisensor capacitance probes (MCPs) have traditionally been used for soil moisture monitoring and irrigation scheduling. This paper presents a new application of these probes, namely the simultaneous monitoring of ponded water level, soil moisture, and temperature profile, conditions which are particularly important for rice crops in temperate growing regions and for rice grown with prolonged periods of drying. WiFi-based loggers are used to concurrently collect the data from the MCPs and ultrasonic distance sensors (giving an independent reading of water depth). Models are fit to MCP water depth vs volumetric water content (VWC) characteristics from laboratory measurements, variability from probe-to-probe is assessed, and the methodology is verified using measurements from a rice field throughout a growing season. The root-mean-squared error of the water depth calculated from MCP VWC over the rice growing season was 6.6 mm. MCPs are used to simultaneously monitor ponded water depth, soil moisture content when ponded water is drained, and temperatures in root, water, crop and ambient zones. The insulation effect of ponded water against cold-temperature effects is demonstrated with low and high water levels. The developed approach offers advantages in gaining the full soil-plant-atmosphere continuum in a single robust sensor.

  2. Constraining the CMB optical depth through the dispersion measure of cosmological radio transients

    International Nuclear Information System (INIS)

    Fialkov, A.; Loeb, A.

    2016-01-01

    The dispersion measure of extragalactic radio transients can be used to measure the column density of free electrons in the intergalactic medium. The same electrons also scatter the Cosmic Microwave Background (CMB) photons, affecting precision measurements of cosmological parameters. We explore the connection between the dispersion measure of radio transients existing during the Epoch of Reionization (EoR) and the total optical depth for the CMB showing that the existence of such transients would provide a new sensitive probe of the CMB optical depth. As an example, we consider the population of FRBs. Assuming they exist during the EoR, we show that: (i) such sources can probe the reionization history by measuring the optical depth to sub-percent accuracy, and (ii) they can be detected with high significance by an instrument such as the Square Kilometer Array.

  3. Constraining the CMB optical depth through the dispersion measure of cosmological radio transients

    Energy Technology Data Exchange (ETDEWEB)

    Fialkov, A.; Loeb, A., E-mail: anastasia.fialkov@cfa.harvard.edu, E-mail: aloeb@cfa.harvard.edu [Institute for Teory and Computation, Harvard University, 60 Garden Street, MS-51, Cambridge, MA, 02138 (United States)

    2016-05-01

    The dispersion measure of extragalactic radio transients can be used to measure the column density of free electrons in the intergalactic medium. The same electrons also scatter the Cosmic Microwave Background (CMB) photons, affecting precision measurements of cosmological parameters. We explore the connection between the dispersion measure of radio transients existing during the Epoch of Reionization (EoR) and the total optical depth for the CMB showing that the existence of such transients would provide a new sensitive probe of the CMB optical depth. As an example, we consider the population of FRBs. Assuming they exist during the EoR, we show that: (i) such sources can probe the reionization history by measuring the optical depth to sub-percent accuracy, and (ii) they can be detected with high significance by an instrument such as the Square Kilometer Array.

  4. Development and application of VISAR probe with higher signal-collecting efficiency and adjusted depth of field

    International Nuclear Information System (INIS)

    Zhao Jianheng; Sun Chengwei; Ma Ruchao

    2001-01-01

    The new design of optical fiber VISAR probes has been described. It consists of optical fibers and two lenses, and has simpler structure and lower cost than others. If the size of the image near the end face of collecting fiber is larger than the diameter of the core fiber, the distance between the probe and the target can be decreased. Requirement for the precision in the design is lower in this way, and is easier to build up. At the same time, the signal-collecting efficiency is improved in some degree. During the process of designing the probe, the technique for manufacturing the lens of plexiglass is developed. The lens of plexiglass is used to replace the lens of glass, which can reduce the cost of the probe. The factors affecting the collecting efficiency are analyzed

  5. A study of estimating cutting depth for multi-pass nanoscale cutting by using atomic force microscopy

    International Nuclear Information System (INIS)

    Lin, Zone-Ching; Hsu, Ying-Chih

    2012-01-01

    This paper studies two models for estimating cutting depth of multi-pass nanoscale cutting by using an atomic force microscopy (AFM) probe. One estimates cutting depth for multi-pass nanoscale cutting by using regression equations of nanoscale contact pressure factor (NCP factor) while the other uses equation of specific down force energy (SDFE). This paper proposes taking a diamond-coated probe of AFM as the cutting tool to carry out multi-pass nanoscale cutting experiments on the surface of sapphire substrate. In the process of experimentation, different down forces are set, and the probe shape of AFM is known, then using each down force to multi-pass cutting the sapphire substrate. From the measured experimental data of a central cutting depth of the machining groove by AFM, this paper calculates the specific down force energy of each down force. The experiment results reveal that the specific down force energy of each case of multi-pass nanoscale cutting for different down forces under a probe of AFM is close to a constant value. This paper also compares the nanoscale cutting results from estimating cutting depths for each pass of multi-pass among the experimental results and the calculating results obtained by the two theories models. It is found that the model of specific down force energy can calculate cutting depths for each nanoscale cutting pass by one equation. It is easier to use than the multi-regression equations of the nanoscale contact pressure factor. Besides, the estimations of cutting depth results obtained by the model of specific down force energy are closer to that of the experiment results. It shows that the proposed specific down force energy model in this paper is an acceptable model.

  6. Urethral alarm probe for permanent prostate implants

    International Nuclear Information System (INIS)

    Cutajar, D.; Lerch, M.; Takacs, G.

    2008-01-01

    We have developed a urethral dosimetry system for real time dose verification along the urethra during permanent implant prostate brachytherapy. The urethral alarm uses 'spectroscopic dosimetry' to calculate the dose rate along the urethra in real time. The application of spectroscopic dosimetry for the urethral alarm probe was verified using Monte Carlo calculations. In phantom depth dose measurements as well as isotropy measurements were performed to verify the usefulness of the urethra alarm probe as an in vivo real time dosimeter. (author)

  7. Evaluation of the Transient Eddy Current Potential Drop of a Four Point Probe

    Science.gov (United States)

    Bowler, J. R.

    2009-03-01

    The transient electrical potential drop of a four point probe has been calculated for the case where a current pulse is injected into a conductive plate via two surface contact electrodes and the voltage measured between two other contact electrodes. The four contact points can be co-linear but this is not always case. For example, they can form a rectangle. Usually such probes carry direct current or alternating current and are used to measure electrical conductivity, crack dimensions or variations of conductivity and magnetic permeability with depth. However, the advantage of a current pulse excitation is that information on the variations of material properties with depth can be acquired rapidly and conveniently. What is needed is a means to infer material properties such as the conductivity variations with depth from the transient field measurements. Here, as an initial step in developing this analysis, we report on the evaluation of transient potential drop signals for four point probes on a homogeneous conductive plates.

  8. The use of neutron probes to determine evapotranspiration

    International Nuclear Information System (INIS)

    Can, O.; Kurttas, Y. S. K.

    2009-01-01

    Water is an essential requirement for life on the planet. It is often the single most limiting factor in crop and livestock production. Water is a scarce resource in many urban and rural environments worldwide. According to the FAO, the global demand for fresh water is doubling every 21 years. The quality of the finite water supplies is also under threat from industrial, agricultural and domestic sources of pollution. The majority of crops are grown under rain-fed conditions and adequate water supply is the main factor limiting crop production in semi-arid and sub-humid regions. On the other hand, currently 20% of the world's arable land is under irrigation providing 35 to 40% of all agricultural production. Irrigation mismanagement poses a serious threat to the environment through groundwater pollution and salinization. It is therefore, essential that water resources be used efficiently by regular monitoring of soil-water status in the unsaturated zone. The neutron depth probe, a nuclear-based technique, is utilized worldwide for this purpose. For a given region, the water balance is given by I+P-(D+ET)-R=±ΔS where P is the rainfall integrated over Δt (mm), I is the irrigation integrated over Δt (mm), ET is the evapotranspiration integrated over Δt (mm), R is the runoff integrated over Δt (mm), D is the water draining from the soil at depth L integrated over Δt (mm), and ΔS is the change in soil-water storage in layer during the interval Δt (mm) The most commonly used values of Δt are a few days, a week, a month, and a year. The increase or decrease of soil moisture in a given soil depth, can easily monitor with neutron probes. When the neutron probe calibration is done, the amount of moisture in the soil at the desired frequency and depth can be learned quickly. In 2006 a study for the evapotranspiration of satsuma mandarin tree has been identified. In a irrigation period (01-31.08.2006) for four soil layer, ET : 78,04 mm. in 0-30 cm depth, ET: 50,01 mm

  9. Size matters: Perceived depth magnitude varies with stimulus height.

    Science.gov (United States)

    Tsirlin, Inna; Wilcox, Laurie M; Allison, Robert S

    2016-06-01

    Both the upper and lower disparity limits for stereopsis vary with the size of the targets. Recently, Tsirlin, Wilcox, and Allison (2012) suggested that perceived depth magnitude from stereopsis might also depend on the vertical extent of a stimulus. To test this hypothesis we compared apparent depth in small discs to depth in long bars with equivalent width and disparity. We used three estimation techniques: a virtual ruler, a touch-sensor (for haptic estimates) and a disparity probe. We found that depth estimates were significantly larger for the bar stimuli than for the disc stimuli for all methods of estimation and different configurations. In a second experiment, we measured perceived depth as a function of the height of the bar and the radius of the disc. Perceived depth increased with increasing bar height and disc radius suggesting that disparity is integrated along the vertical edges. We discuss size-disparity correlation and inter-neural excitatory connections as potential mechanisms that could account for these results. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Spatiotemporal fusion of multiple-satellite aerosol optical depth (AOD) products using Bayesian maximum entropy method

    Science.gov (United States)

    Tang, Qingxin; Bo, Yanchen; Zhu, Yuxin

    2016-04-01

    Merging multisensor aerosol optical depth (AOD) products is an effective way to produce more spatiotemporally complete and accurate AOD products. A spatiotemporal statistical data fusion framework based on a Bayesian maximum entropy (BME) method was developed for merging satellite AOD products in East Asia. The advantages of the presented merging framework are that it not only utilizes the spatiotemporal autocorrelations but also explicitly incorporates the uncertainties of the AOD products being merged. The satellite AOD products used for merging are the Moderate Resolution Imaging Spectroradiometer (MODIS) Collection 5.1 Level-2 AOD products (MOD04_L2) and the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Deep Blue Level 2 AOD products (SWDB_L2). The results show that the average completeness of the merged AOD data is 95.2%,which is significantly superior to the completeness of MOD04_L2 (22.9%) and SWDB_L2 (20.2%). By comparing the merged AOD to the Aerosol Robotic Network AOD records, the results show that the correlation coefficient (0.75), root-mean-square error (0.29), and mean bias (0.068) of the merged AOD are close to those (the correlation coefficient (0.82), root-mean-square error (0.19), and mean bias (0.059)) of the MODIS AOD. In the regions where both MODIS and SeaWiFS have valid observations, the accuracy of the merged AOD is higher than those of MODIS and SeaWiFS AODs. Even in regions where both MODIS and SeaWiFS AODs are missing, the accuracy of the merged AOD is also close to the accuracy of the regions where both MODIS and SeaWiFS have valid observations.

  11. Laser measure of sea salinity, temperature and turbidity in depth

    Science.gov (United States)

    Hirschberg, J. G.; Wouters, A. W.; Byrne, J. D.

    1974-01-01

    A method is described in which a pulsed laser is used to probe the sea. Backscattered light is analyzed in time, intensity and wavelength. Tyndall, Raman and Brillouin scattering are used to obtain the backscatter turbidity, sound velocity, salinity, and the temperature as a function of depth.

  12. Variations in depth-dose data between open and wedge fields for 4-MV x-rays

    International Nuclear Information System (INIS)

    Sewchand, W.; Khan, F.M.; Williamson, J.

    1978-01-01

    Central-axis depth-dose data for 4-MV x rays, including tissue-maximum ratios, were measured for wedge fields. Comparison with corresponding open-field data revealed differences in magnitude which increased with depth, field size, and wedge thickness. However, phantom scatter correction factors for the wedge fields differed less than 1% from corresponding open-field factors. The differences in central-axis percent depth doses between the two types of fields indicate beam hardening by the wedge filter. This study also implies that the derivation of tissue-maximum ratios from central-axis percent depth is as valid for wedge as for open fields

  13. A Novel Method for Remote Depth Estimation of Buried Radioactive Contamination.

    Science.gov (United States)

    Ukaegbu, Ikechukwu Kevin; Gamage, Kelum A A

    2018-02-08

    Existing remote radioactive contamination depth estimation methods for buried radioactive wastes are either limited to less than 2 cm or are based on empirical models that require foreknowledge of the maximum penetrable depth of the contamination. These severely limits their usefulness in some real life subsurface contamination scenarios. Therefore, this work presents a novel remote depth estimation method that is based on an approximate three-dimensional linear attenuation model that exploits the benefits of using multiple measurements obtained from the surface of the material in which the contamination is buried using a radiation detector. Simulation results showed that the proposed method is able to detect the depth of caesium-137 and cobalt-60 contamination buried up to 40 cm in both sand and concrete. Furthermore, results from experiments show that the method is able to detect the depth of caesium-137 contamination buried up to 12 cm in sand. The lower maximum depth recorded in the experiment is due to limitations in the detector and the low activity of the caesium-137 source used. Nevertheless, both results demonstrate the superior capability of the proposed method compared to existing methods.

  14. Nuclear borehole probes - theory and experiments

    International Nuclear Information System (INIS)

    Joergensen, J.L.; Korsbech, U.; Gynther Nielsen, K.; Oelgaard, P.L.

    1985-06-01

    The report gives a summary of the theoretical and expeimental work on borehole probes that has been performed since 1971 at The Department of Electrophysics, The Technical University of Denmark. The first part of the report concerns the use of a spectral natural gamma-ray probe (SNG-probe), which is used for measurements of the spectral distribution of the gamma-rays of the geological strata around a borehole. In general the spectrum is divided into three parts - the gamma-rays from potassium-40, from thorium-232 and daughters, and from uranium-238 and daughters. A set of curves showing the intensities of the gamm-radiation from K, Th, and U versus depth is called a SNG-log. If proper calibrated, the SNG-log gives the concentration of Th, U, and K in the formation surrounding the borehole. Initially the basis for an interpretation of SNG-logs is discussed. Then follows a description og some SNG-problems designed and built by The Department of Electrophysics, and a discussion of the calibration of SNG-probes. Some examples of SNG-logs are presented, and some general comments on the use of SNG-logs are given. The second part of the report concerns mainly the development of theoretical models for neutron-neutron probes, gamma-gamma probes, and pulsed-neutron probes. The purpose of this work has been to examine how well the models correlate with measured results and - where reasonable agreement is found - to use the models in studies of the factors that affect the probe responses in interpretation of experimental results and in probe design. (author)

  15. Automatic maximum entropy spectral reconstruction in NMR

    International Nuclear Information System (INIS)

    Mobli, Mehdi; Maciejewski, Mark W.; Gryk, Michael R.; Hoch, Jeffrey C.

    2007-01-01

    Developments in superconducting magnets, cryogenic probes, isotope labeling strategies, and sophisticated pulse sequences together have enabled the application, in principle, of high-resolution NMR spectroscopy to biomolecular systems approaching 1 megadalton. In practice, however, conventional approaches to NMR that utilize the fast Fourier transform, which require data collected at uniform time intervals, result in prohibitively lengthy data collection times in order to achieve the full resolution afforded by high field magnets. A variety of approaches that involve nonuniform sampling have been proposed, each utilizing a non-Fourier method of spectrum analysis. A very general non-Fourier method that is capable of utilizing data collected using any of the proposed nonuniform sampling strategies is maximum entropy reconstruction. A limiting factor in the adoption of maximum entropy reconstruction in NMR has been the need to specify non-intuitive parameters. Here we describe a fully automated system for maximum entropy reconstruction that requires no user-specified parameters. A web-accessible script generator provides the user interface to the system

  16. A new method for intraoperative localization of epilepsy focus by means of a gamma probe

    International Nuclear Information System (INIS)

    Carneiro Filho, Omar; Vilela Filho, Osvaldo; Ragazzo, Paulo Cesar; Fonseca, Lea Mirian Barbosa da

    2014-01-01

    Objective: to evaluate the utility of a new multimodal image-guided intervention technique to detect epileptogenic areas with a gamma probe as compared with intraoperative electrocorticography. Materials and methods: two symptomatic patients with refractory epilepsy underwent magnetic resonance imaging, videoelectroencephalography, brain SPECT scan, neuropsychological evaluation and were submitted to gamma probe-assisted surgery. Results: in patient 1, maximum radioactive count was initially observed on the temporal gyrus at about 3.5 cm posteriorly to the tip of the left temporal lobe. After corticotomy, the gamma probe indicated maximum count at the head of the hippocampus, in agreement with the findings of intraoperative electrocorticography. In patient 2, maximum count was observed in the occipital region at the transition between the temporal and parietal lobes (right hemisphere). During the surgery, the area of epileptogenic activity mapped at electrocorticography was also delimited, demarcated, and compared with the gamma probe findings. After lesionectomy, new radioactive counts were performed both in the patients and on the surgical specimens (ex-vivo). Conclusion: the comparison between intraoperative electrocorticography and gamma probe-assisted surgery showed similarity of both methods. The advantages of gamma probe include: noninvasiveness, low cost and capacity to demonstrate decrease in the radioactive activity at the site of excision after lesionectomy. (author)

  17. Solid-state NMR paramagnetic relaxation enhancement immersion depth studies in phospholipid bilayers

    KAUST Repository

    Chu, Shidong; Maltsev, Sergey B.; Emwas, Abdul-Hamid M.; Lorigan, Gary A.

    2010-01-01

    A new approach for determining the membrane immersion depth of a spin-labeled probe has been developed using paramagnetic relaxation enhancement (PRE) in solid-state NMR spectroscopy. A DOXYL spin label was placed at different sites of 1-palmitoyl-2

  18. Endoscopic optical coherence tomography with a focus-adjustable probe.

    Science.gov (United States)

    Liao, Wenchao; Chen, Tianyuan; Wang, Chengming; Zhang, Wenxin; Peng, Zhangkai; Zhang, Xiao; Ai, Shengnan; Fu, Deyong; Zhou, Tieying; Xue, Ping

    2017-10-15

    We present a focus-adjustable endoscopic probe for optical coherence tomography (OCT), which is able to acquire images with different focal planes and overcome depth-of-focus limitations by image fusing. The use of a two-way shape-memory-alloy spring enables the probe to adjust working distance over 1.5 mm, providing a large scanning range with high resolution and no sensitivity loss. Equipped with a homemade hollow-core ultrasonic motor, the probe is capable of performing an unobstructed 360 deg field-of-view distal scanning. Both the axial resolution and the best lateral resolution are ∼4  μm, with a sensitivity of 100.3 dB. Spectral-domain OCT imaging of phantom and biological tissues with the probe is also demonstrated.

  19. First results on a laser-heated emissive probe

    International Nuclear Information System (INIS)

    Madani, R.; Klinger, T.; Ionita, C.; Schrittwieser, R.

    2004-01-01

    The floating potential V(fl,em) of a probe, emitting a sufficiently high electron current, yields a fairly accurate approximation of Φ(pl). This is an advantage in comparison to the conventional Langmuir probe where, after determination of the electron temperature T e , the plasma potential can only be derived indirectly from the formula Φ(pl) = V(fl) + α*T e , where α is a function of the ratio of the electron to the ion saturation currents (α is around 2.4 in a magnetized hydrogen plasma). In addition, an emissive probe also works if there are electron drifts or beams in the plasma. Emissive probes are usually realised by small directly heated loops of W-wire. Drawbacks of this design are the limited lifetime, the low electron emissivity of W and the voltage drop across the wire. We have developed a new type of emissive probe, which is heated by an infrared high-power diode laser with a maximum output power of 50 W. The probe consists of a small cylinder of LaB 6 . The probe was inserted into the edge region of the VINETA helicon discharge plasma. Basic features of emissive probes were checked. (authors)

  20. Probing around implants and teeth with healthy or inflamed peri-implant mucosa/gingival. A histologic comparison in cynomolgus monkeys. (Macaca fascicularis)

    DEFF Research Database (Denmark)

    Schou, Søren; Holmstrup, Palle; Stoltze, K.

    2002-01-01

    Osseointegrated oral implants; teeth; phathology; peri-implant mucositis; gingivitis; peri-implantitis; periodontitis; diagnosis; probing depth; non-human primates; cynomolgus monkeys: Macaca fascicularis......Osseointegrated oral implants; teeth; phathology; peri-implant mucositis; gingivitis; peri-implantitis; periodontitis; diagnosis; probing depth; non-human primates; cynomolgus monkeys: Macaca fascicularis...

  1. Survey on depth distribution of underground structures for consideration of human intrusion into TRU waste repository

    International Nuclear Information System (INIS)

    Sakamoto, Yoshiaki; Senoo, Muneaki; Sugimoto, Junichiro; Ohishi, Kiyotaka; Okishio, Masanori; Shimizu, Haruo.

    1996-01-01

    Depth distributions of some kinds of underground structure in Japan have been investigated to get an information about suitable depth of underground repository for TRU waste that is arising from reprocessing and MOX fuel fabrication plants. The underground structures investigated in this work were foundation pile of multistoried building, that of elevated expressway, that of JR shinkansen railway, tunnel of subway and wells. The major depth distribution of the underground structures except for the wells was in range from 30 to 50m, and their maximum depth was less than 100m. On the other hand, the 99% of wells was less than 300m in depth. Maximum depth of the other underground structures has been also investigated for a survey of the utilization of underground by artificial structures in Japan. (author)

  2. Versatile Gaussian probes for squeezing estimation

    Science.gov (United States)

    Rigovacca, Luca; Farace, Alessandro; Souza, Leonardo A. M.; De Pasquale, Antonella; Giovannetti, Vittorio; Adesso, Gerardo

    2017-05-01

    We consider an instance of "black-box" quantum metrology in the Gaussian framework, where we aim to estimate the amount of squeezing applied on an input probe, without previous knowledge on the phase of the applied squeezing. By taking the quantum Fisher information (QFI) as the figure of merit, we evaluate its average and variance with respect to this phase in order to identify probe states that yield good precision for many different squeezing directions. We first consider the case of single-mode Gaussian probes with the same energy, and find that pure squeezed states maximize the average quantum Fisher information (AvQFI) at the cost of a performance that oscillates strongly as the squeezing direction is changed. Although the variance can be brought to zero by correlating the probing system with a reference mode, the maximum AvQFI cannot be increased in the same way. A different scenario opens if one takes into account the effects of photon losses: coherent states represent the optimal single-mode choice when losses exceed a certain threshold and, moreover, correlated probes can now yield larger AvQFI values than all single-mode states, on top of having zero variance.

  3. Advanced characterization of carrier profiles in germanium using micro-machined contact probes

    DEFF Research Database (Denmark)

    Clarysse, T.; Konttinen, M.; Parmentier, B.

    2012-01-01

    of new concepts based on micro machined, closely spaced contact probes (10 μm pitch). When using four probes to perform sheet resistance measurements, a quantitative carrier profile extraction based on the evolution of the sheet resistance versus depth along a beveled surface is obtained. Considering...... the properties of both approaches on Al+ implants in germanium with different anneal treatments....

  4. A Miniature Four-Hole Probe for Measurement of Three-Dimensional Flow with Large Gradients

    Directory of Open Access Journals (Sweden)

    Ravirai Jangir

    2014-01-01

    Full Text Available A miniature four-hole probe with a sensing area of 1.284 mm2 to minimise the measurement errors due to the large pressure and velocity gradients that occur in highly three-dimensional turbomachinery flows is designed, fabricated, calibrated, and validated. The probe has good spatial resolution in two directions, thus minimising spatial and flow gradient errors. The probe is calibrated in an open jet calibration tunnel at a velocity of 50 m/s in yaw and pitch angles range of ±40 degrees with an interval of 5 degrees. The calibration coefficients are defined, determined, and presented. Sensitivity coefficients are also calculated and presented. A lookup table method is used to determine the four unknown quantities, namely, total and static pressures and flow angles. The maximum absolute errors in yaw and pitch angles are 2.4 and 1.3 deg., respectively. The maximum absolute errors in total, static, and dynamic pressures are 3.4, 3.9, and 4.9% of the dynamic pressures, respectively. Measurements made with this probe, a conventional five-hole probe and a miniature Pitot probe across a calibration section, demonstrated that the errors due to gradient and surface proximity for this probe are considerably reduced compared to the five-hole probe.

  5. A comparison of conventional maximum intensity projection with a new depth-specific topographic mapping technique in the CT analysis of proximal tibial subchondral bone density

    International Nuclear Information System (INIS)

    Johnston, James D.; Kontulainen, Saija A.; Masri, Bassam A.; Wilson, David R.

    2010-01-01

    The objective was to identify subchondral bone density differences between normal and osteoarthritic (OA) proximal tibiae using computed tomography osteoabsorptiometry (CT-OAM) and computed tomography topographic mapping of subchondral density (CT-TOMASD). Sixteen intact cadaver knees from ten donors (8 male:2 female; mean age:77.8, SD:7.4 years) were categorized as normal (n = 10) or OA (n = 6) based upon CT reconstructions. CT-OAM assessed maximum subchondral bone mineral density (BMD). CT-TOMASD assessed average subchondral BMD across three layers (0-2.5, 2.5-5 and 5-10 mm) measured in relation to depth from the subchondral surface. Regional analyses of CT-OAM and CT-TOMASD included: medial BMD, lateral BMD, and average BMD of a 10-mm diameter area that searched each medial and lateral plateau for the highest ''focal'' density present within each knee. Compared with normal knees, both CT-OAM and CT-TOMASD demonstrated an average of 17% greater whole medial compartment density in OA knees (p 0.05). CT-TOMASD focal region analyses revealed an average of 24% greater density in the 0- to 2.5-mm layer (p = 0.003) and 36% greater density in the 2.5- to 5-mm layer (p = 0.034) in OA knees. Both CT-OAM and TOMASD identified higher medial compartment density in OA tibiae compared with normal tibiae. In addition, CT-TOMASD indicated greater focal density differences between normal and OA knees with increased depth from the subchondral surface. Depth-specific density analyses may help identify and quantify small changes in subchondral BMD associated with OA disease onset and progression. (orig.)

  6. Correlation of gingival thickness with gingival width, probing depth, and papillary fill in maxillary anterior teeth in students of a dental college in Navi Mumbai.

    Science.gov (United States)

    Singh, Jyotsna; Rathod, Varsha J; Rao, Prajakta R; Patil, Aardra A; Langade, Deepak G; Singh, Roshan K

    2016-01-01

    The gingival biotype is of utmost importance for esthetics and biologic function. Anatomical characteristic of periodontium such as gingival thickness (GT), width of keratinized gingiva, and alveolar bone morphology will determine the behavior of periodontium when subjected to physical, chemical, or bacterial insult or during therapeutic procedure. The aim of this study was to correlate the GT with gingival width (GW), probing depth (PD), and papillary fill (PF) in relation to maxillary anterior region. Undergraduate dental students and interns from a dental college in Navi Mumbai were enrolled in the study according to the inclusion criteria. Six teeth per subject were assessed; a total of 2178 maxillary anterior teeth were examined. Subjects were examined clinically for GT, width of keratinized gingiva, pocket depth, and interdental PF. The data obtained was tabulated and subjected to statistical analysis. Spearman's correlation analysis test was performed to find the correlation of GT with GW, PD, and PF. Positive correlation was found between GT and GW ( r = 0.241). No significant correlation could be found between GT and PD; and between GT and PF. The present study confirmed a positive correlation between GT and GW. A weak negative correlation was found between GT and PD.

  7. Clinical Application of Colour Modulation of Gamma Energy and Depth by Dual-Channel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Kaplan, E.; Ben-Porath, M. [Veterans Administration Hospital, Hines, IL (United States)

    1969-01-15

    A dual-channel scanning system has been described permitting the simultaneous imaging in individual color of the distribution of two gamma-emitting radioisotopes. In those cases where two organs are adjacent and concentrate the same isotope, they may be displayed in separate color if one of the organs concentrates another gamma-emitting isotope with a different energy. This is accomplished by individual color readout of this isotope and the display of the subtraction of this isotope from the common isotope in another color. By using two facing scintillation probes on either side of the individual being scanned, two overlapping organs at different depths concentrating the same isotope can be color differentiated by a dual-channel playout of each probe. The principal application of these dual-channel scanning methods to date has been the simultaneous display of the liver and pancreas in individual colors using {sup 198}Au and {sup 75}selenomethionine. Characteristic scans have been obtained which differentiate a number of disease states from the normal pancreas and liver. The pancreatic and liver diseases studied and characterized are carcinoma of the pancreas, pancreatic insufficiency, acute recurrent pancreatitis, pancreatic pseudocyst and Laennec's cirrhosis, hepatoma and metastatic malignancy in the liver. The uptake of {sup 75}selenomethionine in malignant lesions in many instances produces positive scans of these tumors in contrasting color to the liver. Depth discrimination in color with the two-probe system has permitted the lateralization of intracranial lesions, the color of the display being proportional to the depth of the lesion. The discrimination of depth and gamma-ray energy by dual-channel color scanning and its general application in visualizing other organs has been accomplished. (author)

  8. Nutrient availability at Mer Bleue bog measured by PRSTM probes

    Science.gov (United States)

    Wang, M.; Moore, T. R.; Talbot, J.

    2015-12-01

    Bogs, covering ~0.7 million km2 in Canada, store a large amount of C and N. As nutrient deficient ecosystems, it's critical to examine the nutrient availabilities and seasonal dynamics. We used Plant Root Simulators (PRSTM) at Mer Bleue bog to provide some baseline data on nutrient availability and its variability. In particular, we focused on ammonium, nitrate, phosphate, calcium, magnesium and potassium, iron, sulphate and aluminum. We placed PRS probes at a depth of 5 - 15 cm in pristine plots and plots with long term N, P and K fertilization for 4 weeks and determined the availability of these nutrients, from spring through to fall. Probes were also placed beneath the water table in hummock and hollow microtopography and along a transect including part of the bog which had been drained through the creation of a ditch 80 years ago. The result showed that there was limited available ammonium, nitrate and phosphate in the bog, the seasonal variation of nutrient availabilities probably due to mineralization, an increase in the availability of some nutrients between different water table depths or as a result of drainage, and the relative availability of nutrients compared to the input from fertilization. We suggest that PRS probes could be a useful tool to examine nutrient availability and dynamics in wetlands, with careful consideration of installing condition, for example, proper exposure period, depth relative to water table etc.

  9. Bilateral differences in peak force, power, and maximum plie depth during multiple grande jetes

    NARCIS (Netherlands)

    Wyon, M.; Harris, J.; Brown, D.D.; Clark, F.

    2013-01-01

    A lateral bias has been previously reported in dance training. The aim of this study was to investigate whether there are any bilateral differences in peak forces, power, and maximum knee flexion during a sequence of three grand jetes and how they relate to leg dominance. A randomised observational

  10. Diffusion probe for gas sampling in undisturbed soil

    DEFF Research Database (Denmark)

    Petersen, Søren O

    2014-01-01

    Soil-atmosphere fluxes of trace gases such as methane (CH4) and nitrous oxide (N2O) are determined by complex interactions between biological activity and soil conditions. Soil gas concentration profiles may, in combination with other information about soil conditions, help to understand emission...... controls. This note describes a simple and robust diffusion probe for soil gas sampling as part of flux monitoring programs. It can be deployed with minimum disturbance of in-situ conditions, also at sites with a high or fluctuating water table. Separate probes are used for each sampling depth...... on peat soils used for grazing showed soil gas concentrations of CH4 and N2O as influenced by topography, site conditions, and season. The applicability of the diffusion probe for trace gas monitoring is discussed....

  11. Multi-site and multi-depth near-infrared spectroscopy in a model of simulated (central) hypovolemia: Lower body negative pressure

    NARCIS (Netherlands)

    S.A. Bartels (Sebastiaan); R. Bezemer (Rick); F.J.W. Wallis de Vries (Floris); D.M.J. Milstein (Dan); A.A.P. Lima (Alexandre ); T.G.V. Cherpanath (Thomas); A.H. van den Meiracker (Anton); J. van Bommel (Jasper); M. Heger (Michal); J.M. Karemaker (John); C. Ince (Can)

    2011-01-01

    textabstractPurpose: To test the hypothesis that the sensitivity of near-infrared spectroscopy (NIRS) in reflecting the degree of (compensated) hypovolemia would be affected by the application site and probing depth. We simultaneously applied multi-site (thenar and forearm) and multi-depth (15-2.5

  12. Redesign of a Low Energy Probe Head

    CERN Document Server

    Rao, Yi-Nong; Ries, Thomas

    2005-01-01

    The present situation of the low energy probe LE2 in TRIUMF cyclotron is that the thickness of the finger 5 is uniform over a radial length of 3.25 inch and its weight which amounts to ~447 g is affecting its re-circulating ball mechanism and causing it to fall below the median plane over its range of movement. We therefore re-design it in order to reduce its weight. First, we made simulations and determined the optimum thickness of the probe head vs its radial length. These simulation results are found to be in good agreement with experimental measurements made. Finally, we calculated the temperature rise caused by the beam power dumped on the probe, and figured out the maximum current of beam that can be dumped on the finger.

  13. Magnetic Probe Construction using Thick-film Technology

    International Nuclear Information System (INIS)

    Takahashi, H.; Sakakibara, S.; Kubota, Y.; Yamada, H.

    2001-01-01

    Thick-film technology has been successfully adapted for the design and fabrication of magnetic probes of a new type suitable for use in the simultaneous ultra-high vacuum and high-temperature environment of a nuclear fusion device. The maximum usable temperature is expected to be around 900 degrees C. This new probe has a specific sensitivity (coupling area per unit volume) an order of magnitude higher than a conventional coil. The new probe in one implementation is capable of simultaneously measuring magnetic field in three orthogonal directions about a single spatial point and in two frequency ranges. Low-frequency coils have a measured coupling area of 296-323 cm squared and a frequency response of about 300 kHz. High-frequency coils have a design coupling area of 12-15 cm squared

  14. In situ lake pollutant survey using prompt-gamma probe

    International Nuclear Information System (INIS)

    Jiunnhsing Chao; Chien Chung

    1991-01-01

    An aluminium-made neutron-gamma probe, consisting of a 1.5 μg 252 Cf neutron source and a high purity germanium detector, was mounted on a mobile floating platform to survey chlorine pollutant concentration in lake water in situ. Laboratory tests for determining the probe operating depth and in situ field trials of a polluted lake were conducted; evaluation of radiation exposure to workers on board was carried out. The polluted chlorine concentration in lake water was found to be 86 ppm, with minimal radiation exposure for the operating crew on board. (author)

  15. SNAP: Small Next-generation Atmospheric Probe Concept

    Science.gov (United States)

    Sayanagi, K. M.; Dillman, R. A.; Atkinson, D. H.; Li, J.; Saikia, S.; Simon, A. A.; Spilker, T. R.; Wong, M. H.; Hope, D.

    2017-12-01

    We present a concept for a small, atmospheric probe that could be flexibly added to future missions that orbit or fly-by a giant planet as a secondary payload, which we call the Small Next-generation Atmospheric Probe (SNAP). SNAP's main scientific objectives are to determine the vertical distribution of clouds and cloud-forming chemical species, thermal stratification, and wind speed as a function of depth. As a case study, we present the advantages, cost and risk of adding SNAP to the future Uranus Orbiter and Probe flagship mission; in combination with the mission's main probe, SNAP would perform atmospheric in-situ measurements at a second location, and thus enable and enhance the scientific objectives recommended by the 2013 Planetary Science Decadal Survey and the 2014 NASA Science Plan to determine atmospheric spatial variabilities. We envision that the science objectives can be achieved with a 30-kg entry probe 0.5m in diameter (less than half the size of the Galileo probe) that reaches 5-bar pressure-altitude and returns data to Earth via the carrier spacecraft. As the baseline instruments, the probe will carry an Atmospheric Structure Instrument (ASI) that measures the temperature, pressure and acceleration, a carbon nanotube-based NanoChem atmospheric composition sensor, and an Ultra-Stable Oscillator (USO) to conduct a Doppler Wind Experiment (DWE). We also catalog promising technologies currently under development that will strengthen small atmospheric entry probe missions in the future. While SNAP is applicable to multiple planets, we examine the feasibility, benefits and impacts of adding SNAP to the Uranus Orbiter and Probe flagship mission. Our project is supported by NASA PSDS3 grant NNX17AK31G.

  16. Electronic structure of Pt-Co cathode catalysts in membrane electrolyte assembly observed by X-ray absorption fine structure spectroscopy with different probing depth

    International Nuclear Information System (INIS)

    Kobayashi, M.; Hidai, S.; Niwa, H.; Harada, Y.; Oshima, M.; Ofuchi, H.; Nakamori, Y.; Aoki, T.

    2010-01-01

    Electronic structures of Pt-Co cathode and Pt-Ru anode catalysts in membrane electrolyte assemblies (MEAs) for polymer electrolyte fuel cell have been investigated using X-ray absorption near edge structure (XANES) spectroscopy, and the changes of electronic structures accompanied with degradation have been observed by comparison between spectra obtained by fluorescence-yield (FY) and conversion-electron-yield (CEY) methods, probing depths of which are several hundreds μm and ∼100 nm, respectively. The Co K XANES spectra of the as-fabricated MEA show that the Co atoms in the cathode are metallic and oxidized Co ions exist at the interface between the cathode and electrolyte. The spectra of the long-time operated MEA suggest that the oxidation of Co makes progress with degradation of the cathode catalysts. In contrast to the Co K XANES spectra, the line shape of the Ru K XANES spectra is unchanged even after the long-time operation.

  17. No support for Heincke's law in hagfish (Myxinidae): lack of an association between body size and the depth of species occurrence.

    Science.gov (United States)

    Schumacher, E L; Owens, B D; Uyeno, T A; Clark, A J; Reece, J S

    2017-08-01

    This study tests for interspecific evidence of Heincke's law among hagfishes and advances the field of research on body size and depth of occurrence in fishes by including a phylogenetic correction and by examining depth in four ways: maximum depth, minimum depth, mean depth of recorded specimens and the average of maximum and minimum depths of occurrence. Results yield no evidence for Heincke's law in hagfishes, no phylogenetic signal for the depth at which species occur, but moderate to weak phylogenetic signal for body size, suggesting that phylogeny may play a role in determining body size in this group. © 2017 The Fisheries Society of the British Isles.

  18. High resolution axicon-based endoscopic FD OCT imaging with a large depth range

    Science.gov (United States)

    Lee, Kye-Sung; Hurley, William; Deegan, John; Dean, Scott; Rolland, Jannick P.

    2010-02-01

    Endoscopic imaging in tubular structures, such as the tracheobronchial tree, could benefit from imaging optics with an extended depth of focus (DOF). This optics could accommodate for varying sizes of tubular structures across patients and along the tree within a single patient. In the paper, we demonstrate an extended DOF without sacrificing resolution showing rotational images in biological tubular samples with 2.5 μm axial resolution, 10 ìm lateral resolution, and > 4 mm depth range using a custom designed probe.

  19. An optical fiber expendable seawater temperature/depth profile sensor

    Science.gov (United States)

    Zhao, Qiang; Chen, Shizhe; Zhang, Keke; Yan, Xingkui; Yang, Xianglong; Bai, Xuejiao; Liu, Shixuan

    2017-10-01

    Marine expendable temperature/depth profiler (XBT) is a disposable measuring instrument which can obtain temperature/depth profile data quickly in large area waters and mainly used for marine surveys, scientific research, military application. The temperature measuring device is a thermistor in the conventional XBT probe (CXBT)and the depth data is only a calculated value by speed and time depth calculation formula which is not an accurate measurement result. Firstly, an optical fiber expendable temperature/depth sensor based on the FBG-LPG cascaded structure is proposed to solve the problems of the CXBT, namely the use of LPG and FBG were used to detect the water temperature and depth, respectively. Secondly, the fiber end reflective mirror is used to simplify optical cascade structure and optimize the system performance. Finally, the optical path is designed and optimized using the reflective optical fiber end mirror. The experimental results show that the sensitivity of temperature and depth sensing based on FBG-LPG cascade structure is about 0.0030C and 0.1%F.S. respectively, which can meet the requirements of the sea water temperature/depth observation. The reflectivity of reflection mirror is in the range from 48.8% to 72.5%, the resonant peak of FBG and LPG are reasonable and the whole spectrum are suitable for demodulation. Through research on the optical fiber XBT (FXBT), the direct measurement of deep-sea temperature/depth profile data can be obtained simultaneously, quickly and accurately. The FXBT is a new all-optical seawater temperature/depth sensor, which has important academic value and broad application prospect and is expected to replace the CXBT in the future.

  20. Movable Thomson scattering system based on optical fiber (TS-probe)

    International Nuclear Information System (INIS)

    Narihara, K.; Hayashi, H.

    2009-01-01

    This paper proposes a movable compact Thomson scattering (TS) system based on optical fibers (TS-probe). A TS-probe consists of a probe head, optical fiber, a laser-diode, polychromators and lock-in amplifiers. A laser beam optics and light collection optics are mounted rigidly on a probe head with a fixed scattering position. Laser light and scattered light are transmitted by flexible optical fibers, enabling us to move the TS-prove head freely during plasma discharge. The light signal scattered from an amplitude-modulated laser is detected against the plasma light based on the principle of the lock-in amplifier. With a modulated laser power of 300W, the scattered signal from a sheet plasma of 15 mm depth and n e -10 19 m -3 will be measured with 10% accuracy by setting the integrating time to 0.1 s. The TS-probe head is like a 1/20 model of the currently operating LHD-TS. (author)

  1. Optical probe for porosity defect detection on inner diameter surfaces of machined bores

    Science.gov (United States)

    Kulkarni, Ojas P.; Islam, Mohammed N.; Terry, Fred L.

    2010-12-01

    We demonstrate an optical probe for detection of porosity inside spool bores of a transmission valve body with diameters down to 5 mm. The probe consists of a graded-index relay rod that focuses a laser beam spot onto the inner surface of the bore. Detectors, placed in the specular and grazing directions with respect to the incident beam, measure the change in scattered intensity when a surface defect is encountered. Based on the scattering signatures in the two directions, the system can also validate the depth of the defect and distinguish porosity from bump-type defects coming out of the metal surface. The system can detect porosity down to a 50-μm lateral dimension and ~40 μm in depth with >3-dB contrast over the background intensity fluctuations. Porosity detection systems currently use manual inspection techniques on the plant floor, and the demonstrated probe provides a noncontact technique that can help automotive manufacturers meet high-quality standards during production.

  2. Depth profiling of helium in Ni and Nb; comparison of different methods

    International Nuclear Information System (INIS)

    Scherzer, B.M.U.; Bay, H.L.; Behrisch, R.; Boergesen, P.; Roth, J.

    1978-01-01

    Depth profiles of 30 keV 3 He + and 4 He + implanted in polycrystalline nickel and single crystal niobium have been measured using the nuclear reactions He(p,p)He and 3 He(d,α) 1 H. The formalism for obtaining depth profiles from Rutherford backscattering spectra has been generalized for the application to nuclear reaction spectra. The profiles obtained by the two different methods agree within the errors introduced by the uncertainties of the reaction cross-section and electronic stopping power data. The 3 He(d,α) 1 H method is a factor of 10-100 more sensitive and has about a factor of 5 better depth resolution than the He(p,p)He method. However, the latter method allows to probe much larger depths and is simultaneously applicable to 4 He as well as to 3 He. Within the experimental uncertainties the depth profiles for 3 He and 4 He are identical. (Auth.)

  3. Application of Piezocomposite Twin, Side by Side, Phased Array UT Probes for the Inspection of Stainless Steel

    International Nuclear Information System (INIS)

    Delaide, M.; Dumas, Ph

    2005-01-01

    UT probes to be used for the examination of coarse-grain structure must allow to detect and size cracks, with a high reliability level. The combination of TRL probes, with phased array and piezocomposite technologies allows to improve probes performances and inspection speed. Single element crystals are replaced by matrix arrays, allowing to deflect and skew the beams, to change the inspection depth. This paper describes the designing, the manufacturing and the characterisation of several probes

  4. Fast reciprocating probe system on the EAST superconducting tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, W.; Chang, J. F.; Wan, B. N.; Xu, G. S.; Li, B.; Xu, C. S.; Yan, N.; Wang, L.; Liu, S. C.; Jiang, M.; Liu, P. [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei 230031 (China); Xiao, C. J. [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei 230031 (China); Department of Physics and Engineering Physics, Plasma Physics Laboratory, University of Saskatchewan, Saskatoon SK S7N 5E2 (Canada)

    2010-11-15

    A new fast reciprocating probe system (FRPS) has been built and installed on the outer midplane of the EAST tokamak to investigate the profiles of the boundary plasma parameters such as electron density and temperature. The system consists of a two-stage motion drive mechanism: slow motion and fast motion. The fast motion is powered by a servo motor, which drives the probe horizontally up to 50 cm to scan the edge region of the EAST tokamak. The maximum velocity achieved is 2 m/s. High velocity and flexible control of the fast motion are the remarkable features of this FRPS. A specially designed connector installed at the front end of the probe shaft makes it easy to install or replace the probe head on FRPS. During the latest experimental campaign in the spring of 2010, a probe head with seven tips, including two tips for a Mach probe, has been used. An example is given for simultaneous profile measurements of the plasma temperature, plasma density, and the plasma flow velocity.

  5. Supporting Situation Assessment through Attention Guidance: A Cost-Benefit and Depth of Processing Analysis

    National Research Council Canada - National Science Library

    Horrey, William J; Wickens, Christopher D

    2001-01-01

    ...). For half the trials, an automated system guided their attention to high-threat units. On two trials a memory probe was administered to assess the depth of processing of information, and on the final trial an automation failure was presented...

  6. Evaluation of canister weld flaw depth for concrete storage cask

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Tae Chul; Cho, Chun Hyung [Korea Radioactive Waste Agency, Daejeon (Korea, Republic of); Jung, Sung Hun; Lee, Young Oh; Jung, In Su [Korea Nuclear Engineering and Service Corp, Daejeon (Korea, Republic of)

    2017-03-15

    Domestically developed concrete storage casks include an internal canister to maintain the confinement integrity of radioactive materials. In this study, we analyzed the depth of flaws caused by loads that propagate canister weld cracks under normal, off-normal and accident conditions, and evaluated the maximum allowable weld flaw depth needed to secure the structural integrity of the canister weld and to reduce the welding time of the internal canister lid of the concrete storage cask. Structural analyses for normal, off-normal and accident conditions were performed using the general-purpose finite element analysis program ABAQUS; the allowable flaw depth was assessed according to ASME B and PV Code Section XI. Evaluation results revealed an allowable canister weld flaw depth of 18.75 mm for the concrete storage cask, which satisfies the critical flaw depth recommended in NUREG-1536.

  7. Investigation of UT procedure for crack depth sizing by phased array UT in Ni-based alloy weld

    International Nuclear Information System (INIS)

    Hirasawa, Taiji; Fukutomi, Hiroyuki

    2013-01-01

    Recently, it has been reported that the primary water stress corrosion cracking (PWSCC) has occurred in nickel based alloy weld components such as steam generator safe end weld, reactor vessel safe end weld, and so on, in PWR. Defect detection and sizing are important in order to ensure the reliable operation and life extension of nuclear power plants. In the reactor vessel safe end weld, it was impossible to measure crack depth of PWSCC. The cracks have occurred in the axial direction of the safe end weld. Furthermore, the cracks had some features such as deep, large aspect ratio (ratio of crack depth and length), sharp geometry of crack tip, and so on. Therefore, development and improvement of defect depth sizing capabilities by ultrasonic testing (UT) have been required. Phased array UT technique was applied with regard to defect depth sizing at the inside inspection in Ni-based alloy welds. Phased array UT was examined a standard block specimen with side drilled holes (SDHs). From the experimental results, the performance of linear array probes and dual matrix array probe were investigated. In the basis of the results, UT procedure for defect depth sizing was investigated and proposed. The UT procedure was applied to the defect depth measurement in Ni-based alloy weld specimen with electric discharge machine (EDM) notches. From these results, good accuracy of defect depth sizing by phased array UT for the inside inspection was shown. Therefore, it was clarified the effectiveness of the UT procedure for defect depth sizing in Ni-based alloy weld. (author)

  8. Electromagnetic methods for measuring materials properties of cylindrical rods and array probes for rapid flaw inspection

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Haiyan [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    The case-hardening process modifies the near-surface permeability and conductivity of steel, as can be observed through changes in alternating current potential drop (ACPD) along a rod. In order to evaluate case depth of case hardened steel rods, analytical expressions are derived for the alternating current potential drop on the surface of a homogeneous rod, a two-layered and a three-layered rod. The case-hardened rod is first modeled by a two-layer rod that has a homogeneous substrate with a single, uniformly thick, homogeneous surface layer, in which the conductivity and permeability values differ from those in the substrate. By fitting model results to multi-frequency ACPD experimental data, estimates of conductivity, permeability and case depth are found. Although the estimated case depth by the two-layer model is in reasonable agreement with the effective case depth from the hardness profile, it is consistently higher than the effective case depth. This led to the development of the three-layer model. It is anticipated that the new three-layered model will improve the results and thus makes the ACPD method a novel technique in nondestructive measurement of case depth. Another way to evaluate case depth of a case hardened steel rod is to use induction coils. Integral form solutions for an infinite rod encircled by a coaxial coil are well known, but for a finite length conductor, additional boundary conditions must be satisfied at the ends. In this work, calculations of eddy currents are performed for a two-layer conducting rod of finite length excited by a coaxial circular coil carrying an alternating current. The solution is found using the truncated region eigenfunction expansion (TREE) method. By truncating the solution region to a finite length in the axial direction, the magnetic vector potential can be expressed as a series expansion of orthogonal eigenfunctions instead of as a Fourier integral. Closed-form expressions are derived for the electromagnetic

  9. Confocal spectroscopic imaging measurements of depth dependent hydration dynamics in human skin in-vivo

    Science.gov (United States)

    Behm, P.; Hashemi, M.; Hoppe, S.; Wessel, S.; Hagens, R.; Jaspers, S.; Wenck, H.; Rübhausen, M.

    2017-11-01

    We present confocal spectroscopic imaging measurements applied to in-vivo studies to determine the depth dependent hydration profiles of human skin. The observed spectroscopic signal covers the spectral range from 810 nm to 2100 nm allowing to probe relevant absorption signals that can be associated with e.g. lipid and water-absorption bands. We employ a spectrally sensitive autofocus mechanism that allows an ultrafast focusing of the measurement spot on the skin and subsequently probes the evolution of the absorption bands as a function of depth. We determine the change of the water concentration in m%. The water concentration follows a sigmoidal behavior with an increase of the water content of about 70% within 5 μm in a depth of about 14 μm. We have applied our technique to study the hydration dynamics of skin before and after treatment with different concentrations of glycerol indicating that an increase of the glycerol concentration leads to an enhanced water concentration in the stratum corneum. Moreover, in contrast to traditional corneometry we have found that the application of Aluminium Chlorohydrate has no impact to the hydration of skin.

  10. Confocal spectroscopic imaging measurements of depth dependent hydration dynamics in human skin in-vivo

    Directory of Open Access Journals (Sweden)

    P. Behm

    2017-11-01

    Full Text Available We present confocal spectroscopic imaging measurements applied to in-vivo studies to determine the depth dependent hydration profiles of human skin. The observed spectroscopic signal covers the spectral range from 810 nm to 2100 nm allowing to probe relevant absorption signals that can be associated with e.g. lipid and water-absorption bands. We employ a spectrally sensitive autofocus mechanism that allows an ultrafast focusing of the measurement spot on the skin and subsequently probes the evolution of the absorption bands as a function of depth. We determine the change of the water concentration in m%. The water concentration follows a sigmoidal behavior with an increase of the water content of about 70% within 5 μm in a depth of about 14 μm. We have applied our technique to study the hydration dynamics of skin before and after treatment with different concentrations of glycerol indicating that an increase of the glycerol concentration leads to an enhanced water concentration in the stratum corneum. Moreover, in contrast to traditional corneometry we have found that the application of Aluminium Chlorohydrate has no impact to the hydration of skin.

  11. Shave-off depth profiling: Depth profiling with an absolute depth scale

    International Nuclear Information System (INIS)

    Nojima, M.; Maekawa, A.; Yamamoto, T.; Tomiyasu, B.; Sakamoto, T.; Owari, M.; Nihei, Y.

    2006-01-01

    Shave-off depth profiling provides profiling with an absolute depth scale. This method uses a focused ion beam (FIB) micro-machining process to provide the depth profile. We show that the shave-off depth profile of a particle reflected the spherical shape of the sample and signal intensities had no relationship to the depth. Through the introduction of FIB micro-sampling, the shave-off depth profiling of a dynamic random access memory (DRAM) tip was carried out. The shave-off profile agreed with a blue print from the manufacturing process. Finally, shave-off depth profiling is discussed with respect to resolutions and future directions

  12. Design of ultrasonic probe and evaluation of ultrasonic waves on E.coli in Sour Cherry Juice

    Directory of Open Access Journals (Sweden)

    B Hosseinzadeh Samani

    2015-09-01

    Whatman filter paper using a vacuum pump (Mehmandoost et al., 2011. Afterwards, the samples were poured into a reactor with diameter and height of 80 and 50 mm, respectively. It is necessary to mention that the dimensions of the reactor were optimized during pretests. Probe design: One of the most common types of horns used for ultrasonic machining technologies is step type horn (Naď, 2010. For obtaining the governing equations on deformation along the step type horn in steady state conditions, Eq. (1 was used. In the solution of the mentioned differential equation, the answers are divided into two subsets and each of the answers is obtained considering the boundary conditions (Hosseinzadeh et al., 2013: (1\tc^2.[(∂S/∂x/(S(x.(∂u(x,t/∂x+(∂^2 u(x,t/〖∂x〗^2 ]=(∂^2 u(x,t/〖∂t〗^2 From Eq. (1, it can be concluded that: (2\tu(x,t=(A cos⁡〖ωx/c〗+B sin⁡〖ωx/c(C cos⁡〖ωt+D sin⁡ωt 〗 〗 The boundary conditions for Eq. (2 are written as follows: (3\t{■(a (∂u(x/∂x=0,x=0@b (∂u(x/∂x=0,x=l@c u(0=u_in } One of the most important parts in probe design is preventing stress concentration in locations in which the area changes. To avoid this problem, the displacement in this section must be equal to zero (Hosseinzadeh et al., 2013. For obtaining the probe length, the displacement equation and the l1 parameter are used: σ=-E.u_in.ω/c.sin⁡〖(ω.x/c〗 (4 In order to determine the maximum axial stress in step type probe, Eq. (3 and (4 are derived and set equal to zero. Therefore, the maximum stress will be equal to: σ_max=π.E.u_in/l (5 Optimization and Modeling using Response Surface Method: Response surface methodology (RSM has an important application in the design, development and formulation of new products, as well as in the improvement of existing product designs. It defines the effect of the independent variables, alone or in combination, on processes. In addition, to analyzing the effects of the independent variables, this

  13. Determination of the magnetic penetration depth in a superconducting Pb film

    International Nuclear Information System (INIS)

    Brisbois, J.; Silhanek, A. V.; Raes, B.; Van de Vondel, J.; Moshchalkov, V. V.

    2014-01-01

    By means of scanning Hall probe microscopy technique, we accurately map the magnetic field pattern produced by Meissner screening currents in a thin superconducting Pb stripe. The obtained field profile allows us to quantitatively estimate the Pearl length Λ without the need of pre-calibrating the Hall sensor. This fact contrasts with the information acquired through the spatial field dependence of an individual flux quantum where the scanning height and the magnetic penetration depth combine in a single inseparable parameter. The derived London penetration depth λ L coincides with the values previously reported for bulk Pb once the kinetic suppression of the order parameter is properly taken into account

  14. Nuclear method for determination of nitrogen depth distributions in single seeds. [/sup 14/N tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Sundqvist, B; Gonczi, L; Koersner, I; Bergman, R; Lindh, U

    1974-01-01

    (d,p) reactions in /sup 14/N were used for probing single kernels of seed for nitrogen content and nitrogen depth distributions. Comparison with the Kjeldahl method was made on individual peas and beans. The results were found to be strongly correlated. The technique to obtain depth distributions of nitrogen was also used on high- and low-lysine varieties of barley for which large differences in nitrogen distributions were found.

  15. Volumetric humidity timely variation, at different depths, in soils of a toposequence of the Reconcavo Baiano - Brazil

    International Nuclear Information System (INIS)

    Ribeiro, Antonio Carlos; Costa, Liovando Marciano da; Paiva, Arlicelio de Queiroz; Souza, Luciano da Silva; Santana, Marlete Bastos

    1997-01-01

    Aiming the time basis volumetric humidity evaluation, at different depths, the present work has been developed in a Reconcavo Baiano toposequence consisting of three different soils, in accordance with the distances from the toposequence begin. A neutron probe has been used for determination of the soil water contents. The relative counting of the neutron probe has been converted to gravimetric humidity by using regression equation for each type of soil

  16. Dealing with imperfection: quantifying potential length scale artefacts from nominally spherical indenter probes

    International Nuclear Information System (INIS)

    Constantinides, G; Silva, E C C M; Blackman, G S; Vliet, K J Van

    2007-01-01

    Instrumented nanoindenters are commonly employed to extract elastic, plastic or time-dependent mechanical properties of the indented material surface. In several important cases, accurate determination of the indenter probe radii is essential for the proper analytical interpretation of the experimental response, and it cannot be circumvented by an experimentally determined expression for the contact area as a function of depth. Current approaches quantify the indenter probe radii via inference from a series of indents on a material with known elastic modulus (e.g., fused quartz) or through the fitting of two-dimensional projected images acquired via atomic force microscopy (AFM) or scanning electron microscopy (SEM) images. Here, we propose a more robust methodology, based on concepts of differential geometry, for the accurate determination of three-dimensional indenter probe geometry. The methodology is presented and demonstrated for four conospherical indenters with probe radii of the order of 1-10 μm. The deviation of extracted radii with manufacturer specifications is emphasized and the limits of spherical approximations are presented. All four probes deviate from the assumed spherical geometry, such that the effective radii are not independent of distance from the probe apex. Significant errors in interpretation of material behaviour will result if this deviation is unaccounted for during the analysis of indentation load-depth responses obtained from material surfaces of interest, including observation of an artificial length scale that could be misinterpreted as an effect attributable to material length scales less than tens of nanometres in size or extent

  17. Effects of Mach number on pitot-probe displacement in a turbulent boundary layer

    Science.gov (United States)

    Allen, J. M.

    1974-01-01

    Experimental pitot-probe-displacement data have been obtained in a turbulent boundary layer at a local free-stream Mach number of 4.63 and unit Reynolds number of 6.46 million meter. The results of this study were compared with lower Mach number results of previous studies. It was found that small probes showed displacement only, whereas the larger probes showed not only displacement but also distortion of the shape of the boundary-layer profile. The distortion pattern occurred lower in the boundary layer at the higher Mach number than at the the lower Mach number. The maximum distortion occurred when the center of the probe was about one probe diameter off the test surface. For probes in the wall contact position, the indicated Mach numbers were, for all probes tested, close to the true profile. Pitot-probe displacement was found to increase significantly with increasing Mach number.

  18. MASEX '83, a survey of the turbidity maximum in the Weser Estuary

    International Nuclear Information System (INIS)

    Fanger, H.U.; Neumann, L.; Ohm, K.; Riethmueller, R.

    1986-01-01

    A one-week survey of the turbidity maximum in the Weser Estuary was conducted in the Fall of 1983 using the survey ship RV 'Victor Hensen'. Supplemental measurements were taken using in-situ current - conductivity - temperature - turbidity meters. The thickness of the bottom mud was determined using a gamma-ray transmission probe and compared with core sample analysis. The location of no-net tidal averaged bottom flow was determined to be at km 57. The off-ship measurements were taken using a CTD probe combined with a light attenuation meter. A comparison between salinity and attenuation gives insight into the relative importance of erosion, sedimentation and advective transport. (orig.) [de

  19. Fluorenyl benzothiadiazole and benzoselenadiazole near-IR fluorescent probes for two-photon fluorescence imaging (Conference Presentation)

    Science.gov (United States)

    Belfield, Kevin D.; Yao, Sheng; Kim, Bosung; Yue, Xiling

    2016-03-01

    Imaging biological samples with two-photon fluorescence (2PF) microscopy has the unique advantage of resulting high contrast 3D resolution subcellular image that can reach up to several millimeters depth. 2PF probes that absorb and emit at near IR region need to be developed. Two-photon excitation (2PE) wavelengths are less concerned as 2PE uses wavelengths doubles the absorption wavelength of the probe, which means 2PE wavelengths for probes even with absorption at visible wavelength will fall into NIR region. Therefore, probes that fluoresce at near IR region with high quantum yields are needed. A series of dyes based on 5-thienyl-2, 1, 3-benzothiadiazole and 5-thienyl-2, 1, 3-benzoselenadiazole core were synthesized as near infrared two-photon fluorophores. Fluorescence maxima wavelengths as long as 714 nm and fluorescence quantum yields as high as 0.67 were achieved. The fluorescence quantum yields of the dyes were nearly constant, regardless of solvents polarity. These diazoles exhibited large Stokes shift (GM), and high two-photon fluorescence figure of merit (FM , 1.04×10-2 GM). Cells incubated on a 3D scaffold with one of the new probes (encapsulated in Pluronic micelles) exhibited bright fluorescence, enabling 3D two-photon fluorescence imaging to a depth of 100 µm.

  20. Prediction of lake depth across a 17-state region in the United States

    Science.gov (United States)

    Oliver, Samantha K.; Soranno, Patricia A.; Fergus, C. Emi; Wagner, Tyler; Winslow, Luke A.; Scott, Caren E.; Webster, Katherine E.; Downing, John A.; Stanley, Emily H.

    2016-01-01

    Lake depth is an important characteristic for understanding many lake processes, yet it is unknown for the vast majority of lakes globally. Our objective was to develop a model that predicts lake depth using map-derived metrics of lake and terrestrial geomorphic features. Building on previous models that use local topography to predict lake depth, we hypothesized that regional differences in topography, lake shape, or sedimentation processes could lead to region-specific relationships between lake depth and the mapped features. We therefore used a mixed modeling approach that included region-specific model parameters. We built models using lake and map data from LAGOS, which includes 8164 lakes with maximum depth (Zmax) observations. The model was used to predict depth for all lakes ≥4 ha (n = 42 443) in the study extent. Lake surface area and maximum slope in a 100 m buffer were the best predictors of Zmax. Interactions between surface area and topography occurred at both the local and regional scale; surface area had a larger effect in steep terrain, so large lakes embedded in steep terrain were much deeper than those in flat terrain. Despite a large sample size and inclusion of regional variability, model performance (R2 = 0.29, RMSE = 7.1 m) was similar to other published models. The relative error varied by region, however, highlighting the importance of taking a regional approach to lake depth modeling. Additionally, we provide the largest known collection of observed and predicted lake depth values in the United States.

  1. Marketable yield of onion under different irrigation depths, with and without mulch

    Directory of Open Access Journals (Sweden)

    Daniel F. de Carvalho

    Full Text Available ABSTRACT The objectives of this study were to obtain the onion crop coefficients and evaluate the influence of different irrigation depths (0, 22, 45, 75 and 100% of crop evapotranspiration on marketable yield and quality of onion bulbs cultivated with and without mulch of elephant grass. The experiment was carried out in Seropédica, RJ, Brazil, from May to September 2012, in a Red Yellow Argisol. The experimental design was in randomized blocks in split plots, with 10 treatments and seven replicates. Irrigation management was performed through soil water balance using the Time Domain Reflectometry technique, with probes installed horizontally at 7.5 and 22.5 cm depths. The use of mulch allowed the application of smaller irrigation depths, leading to lower crop coefficient (18% in stage II and 3% in stage III in comparison to the crop without mulch. Irrigation depths associated with the use of mulch influenced the evaluated production variables, proving to be an alternative to increase marketable yield and quality of onion bulbs, with lower irrigation depth.

  2. There’s plenty of light at the bottom: statistics of photon penetration depth in random media

    Science.gov (United States)

    Martelli, Fabrizio; Binzoni, Tiziano; Pifferi, Antonio; Spinelli, Lorenzo; Farina, Andrea; Torricelli, Alessandro

    2016-01-01

    We propose a comprehensive statistical approach describing the penetration depth of light in random media. The presented theory exploits the concept of probability density function f(z|ρ, t) for the maximum depth reached by the photons that are eventually re-emitted from the surface of the medium at distance ρ and time t. Analytical formulas for f, for the mean maximum depth 〈zmax〉 and for the mean average depth reached by the detected photons at the surface of a diffusive slab are derived within the framework of the diffusion approximation to the radiative transfer equation, both in the time domain and the continuous wave domain. Validation of the theory by means of comparisons with Monte Carlo simulations is also presented. The results are of interest for many research fields such as biomedical optics, advanced microscopy and disordered photonics. PMID:27256988

  3. Temperature of the Icelandic crust: Inferred from electrical conductivity, temperature surface gradient, and maximum depth of earthquakes

    Science.gov (United States)

    Björnsson, Axel

    2008-02-01

    Two different models of the structure of the Icelandic crust have been presented. One is the thin-crust model with a 10-15 km thick crust beneath the axial rift zones, with an intermediate layer of partially molten basalt at the base of the crust and on the top of an up-domed asthenosphere. The thick-crust model assumes a 40 km thick and relatively cold crust beneath central Iceland. The most important and crucial parameter to distinguish between these different models is the temperature distribution with depth. Three methods are used to estimate the temperature distribution with depth. First, the surface temperature gradient measured in shallow wells drilled outside geothermal areas. Second, the thickness of the seismogenic zone which is associated with a 750 °C isothermal surface. Third, the depth to a layer with high electrical conductivity which is associated with partially molten basalt with temperature around 1100 °C at the base of the crust. Combination of these data shows that the temperature gradient can be assumed to be nearly linear from the surface down to the base of the crust. These results are strongly in favour of the thin-crust model. The scattered deep seismic reflectors interpreted as Moho in the thick-crust model could be caused by phase transitions or reflections from melt pockets in the mantle.

  4. Nuclear critical opalescence and electromagnetic probes

    International Nuclear Information System (INIS)

    Delorme, J.

    1980-01-01

    A description of nuclear critical opalescence is presented with emphasis on the information which can be gained from electromagnetic probes. The connection with standard nuclear physics treatments is given. Experimental possibilities are reviewed. Present information from electron scattering is shown to be unconclusive. The maximum sensitivity to critical phenomena would be attained by measurements of longitudinal spin form factors. Photopion reactions are analyzed in this spirit and found to be promising

  5. Intracranial depth electrodes implantation in the era of image-guided surgery

    Directory of Open Access Journals (Sweden)

    Ricardo Silva Centeno

    2011-08-01

    Full Text Available The advent of modern image-guided surgery has revolutionized depth electrode implantation techniques. Stereoelectroencephalography (SEEG, introduced by Talairach in the 1950s, is an invasive method for three-dimensional analysis on the epileptogenic zone based on the technique of intracranial implantation of depth electrodes. The aim of this article is to discuss the principles of SEEG and their evolution from the Talairach era to the image-guided surgery of today, along with future prospects. Although the general principles of SEEG have remained intact over the years, the implantation of depth electrodes, i.e. the surgical technique that enables this method, has undergone tremendous evolution over the last three decades, due the advent of modern imaging techniques, computer systems and new stereotactic techniques. The use of robotic systems, the constant evolution of imaging and computing techniques and the use of depth electrodes together with microdialysis probes will open up enormous prospects for applying depth electrodes and SEEG both for investigative use and for therapeutic use. Brain stimulation of deep targets and the construction of "smart" electrodes may, in the near future, increase the need to use this method.

  6. Intracranial depth electrodes implantation in the era of image-guided surgery.

    Science.gov (United States)

    Centeno, Ricardo Silva; Yacubian, Elza Márcia Targas; Caboclo, Luis Otávio Sales Ferreira; Júnior, Henrique Carrete; Cavalheiro, Sérgio

    2011-08-01

    The advent of modern image-guided surgery has revolutionized depth electrode implantation techniques. Stereoelectroencephalography (SEEG), introduced by Talairach in the 1950s, is an invasive method for three-dimensional analysis on the epileptogenic zone based on the technique of intracranial implantation of depth electrodes. The aim of this article is to discuss the principles of SEEG and their evolution from the Talairach era to the image-guided surgery of today, along with future prospects. Although the general principles of SEEG have remained intact over the years, the implantation of depth electrodes, i.e. the surgical technique that enables this method, has undergone tremendous evolution over the last three decades, due the advent of modern imaging techniques, computer systems and new stereotactic techniques. The use of robotic systems, the constant evolution of imaging and computing techniques and the use of depth electrodes together with microdialysis probes will open up enormous prospects for applying depth electrodes and SEEG both for investigative use and for therapeutic use. Brain stimulation of deep targets and the construction of "smart" electrodes may, in the near future, increase the need to use this method.

  7. Rooting depth and root depth distribution of Trifolium repens × T. uniflorum interspecific hybrids.

    Science.gov (United States)

    Nichols, S N; Hofmann, R W; Williams, W M; van Koten, C

    2016-05-20

    Traits related to root depth distribution were examined in Trifolium repens × T. uniflorum backcross 1 (BC 1 ) hybrids to determine whether root characteristics of white clover could be improved by interspecific hybridization. Two white clover cultivars, two T. uniflorum accessions and two BC 1 populations were grown in 1 -m deep tubes of sand culture. Maximum rooting depth and root mass distribution were measured at four harvests over time, and root distribution data were fitted with a regression model to provide measures of root system shape. Morphological traits were measured at two depths at harvest 3. Root system shape of the hybrids was more similar to T. uniflorum than to white clover. The hybrids and T. uniflorum had a higher rate of decrease in root mass with depth than white clover, which would result in higher proportions of root mass in the upper profile. Percentage total root mass at 100-200 mm depth was higher for T. uniflorum than white clover, and for Crusader BC 1 than 'Crusader'. Roots of the hybrids and T. uniflorum also penetrated deeper than those of white clover. T. uniflorum had thicker roots at 50-100 mm deep than the other entries, and more of its fine root mass at 400-500 mm. The hybrids and white clover had more of their fine root mass higher in the profile. Consequently, T. uniflorum had a higher root length density at 400-500 mm than most entries, and a smaller decrease in root length density with depth. These results demonstrate that rooting characteristics of white clover can be altered by hybridization with T. uniflorum, potentially improving water and nutrient acquisition and drought resistance. Root traits of T. uniflorum are likely to be adaptations to soil moisture and fertility in its natural environment. © The Author 2016. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Probing Ionic Liquid Aqueous Solutions Using Temperature of Maximum Density Isotope Effects

    Directory of Open Access Journals (Sweden)

    Mohammad Tariq

    2013-03-01

    Full Text Available This work is a new development of an extensive research program that is investigating for the first time shifts in the temperature of maximum density (TMD of aqueous solutions caused by ionic liquid solutes. In the present case we have compared the shifts caused by three ionic liquid solutes with a common cation—1-ethyl-3-methylimidazolium coupled with acetate, ethylsulfate and tetracyanoborate anions—in normal and deuterated water solutions. The observed differences are discussed in terms of the nature of the corresponding anion-water interactions.

  9. Critical Assessment of the Surface Tension determined by the Maximum Pressure Bubble Method

    OpenAIRE

    Benedetto, Franco Emmanuel; Zolotucho, Hector; Prado, Miguel Oscar

    2015-01-01

    The main factors that influence the value of surface tension of a liquid measured with the Maximum Pressure Bubble Method are critically evaluated. We present experimental results showing the effect of capillary diameter, capillary depth, bubble spheroidicity and liquid density at room temperature. We show that the decrease of bubble spheroidicity due to increase of capillary immersion depth is not sufficient to explain the deviations found in the measured surface tension values. Thus, we pro...

  10. Time domain diffuse Raman spectrometer based on a TCSPC camera for the depth analysis of diffusive media.

    Science.gov (United States)

    Konugolu Venkata Sekar, S; Mosca, S; Tannert, S; Valentini, G; Martelli, F; Binzoni, T; Prokazov, Y; Turbin, E; Zuschratter, W; Erdmann, R; Pifferi, A

    2018-05-01

    We present a time domain diffuse Raman spectrometer for depth probing of highly scattering media. The system is based on, to the best of our knowledge, a novel time-correlated single-photon counting (TCSPC) camera that simultaneously acquires both spectral and temporal information of Raman photons. A dedicated non-contact probe was built, and time domain Raman measurements were performed on a tissue mimicking bilayer phantom. The fluorescence contamination of the Raman signal was eliminated by early time gating (0-212 ps) the Raman photons. Depth sensitivity is achieved by time gating Raman photons at different delays with a gate width of 106 ps. Importantly, the time domain can provide time-dependent depth sensitivity leading to a high contrast between two layers of Raman signal. As a result, an enhancement factor of 2170 was found for our bilayer phantom which is much higher than the values obtained by spatial offset Raman spectroscopy (SORS), frequency offset Raman spectroscopy (FORS), or hybrid FORS-SORS on a similar phantom.

  11. Study of sapphire probe tip wear when scanning on different materials

    International Nuclear Information System (INIS)

    Nicolet, Anaïs; Küng, Alain; Meli, Felix

    2012-01-01

    The accuracy of today's coordinate measuring machines (CMM) has reached a level at which exact knowledge of each component is required. The role of the probe tip is particularly crucial as it is in contact with the sample surface. Understanding how the probe tip wears off will help to narrow the measurement errors. In this work, wear of a sapphire sphere was studied for different scanning conditions and with different sample materials. Wear depth on the probe was investigated using an automated process in situ on the METAS micro-CMM and completed by measurements with an atomic force microscope. We often found a linear dependence between the wear depth and the scan length ranging from 0.5 to 9 nm m −1 , due to variations in scan speed, contact force or sample material. In the case of steel, the wear rate is proportional to the scan speed, while for aluminum several processes seem to interact. A large amount of debris was visible after the tests. Except for aluminum, wear was visible only on the sphere and not on the sample. Sapphire/steel is the worst combination in terms of wear, whereas the combination sapphire/ceramic exhibits almost no wear. (paper)

  12. A new XRF probe for in-situ determining concentration of multi-elements in ocean sediments

    International Nuclear Information System (INIS)

    Ge Liangquan; Lai Wanchang; Zhou Sichun; Lin Ling; Lin Yanchang; Ren Jiafu

    2001-01-01

    The author introduces a new X-ray fluorescence probe for in-situ determining the concentration of multi-elements in ocean sediments. The probe consists of Si-Pin X-ray detector with an electro-thermal colder, two isotope sources, essential electrical signal processing units and a notebook computer. More than 10 elements can be simultaneously determined at a detection limit of (10-200) x 10 -6 and precision of 5%-30% without liquid Nitrogen supply. tests show that the probe can perform the analytical tasks under the water at the depth of less than 1000 meters

  13. Direct depth distribution measurement of deuterium in bulk tungsten exposed to high-flux plasma

    Directory of Open Access Journals (Sweden)

    C. N. Taylor

    2017-05-01

    Full Text Available Understanding tritium retention and permeation in plasma-facing components is critical for fusion safety and fuel cycle control. Glow discharge optical emission spectroscopy (GD-OES is shown to be an effective tool to reveal the depth profile of deuterium in tungsten. Results confirm the detection of deuterium. A ∼46 μm depth profile revealed that the deuterium content decreased precipitously in the first 7 μm, and detectable amounts were observed to depths in excess of 20 μm. The large probing depth of GD-OES (up to 100s of μm enables studies not previously accessible to the more conventional techniques for investigating deuterium retention. Of particular applicability is the use of GD-OES to measure the depth profile for experiments where high deuterium concentration in the bulk material is expected: deuterium retention in neutron irradiated materials, and ultra-high deuterium fluences in burning plasma environment.

  14. Nuclear critical opalescence and electromagnetic probes

    International Nuclear Information System (INIS)

    Delorme, J.

    1981-01-01

    A description of nuclear critical opalescence is presented with emphasis on the information which can be gained from electromagnetic probes. The connection with standard nuclear physics treatments is given. Experimental possibilities are reviewed. Present information from electron scattering is shown to be unconclusive. The maximum sensitivity to critical phenomena would be attained by measurements of longitudinal spin form factors. Photopion reactions are analyzed in this spirit and found to be promising. (orig.)

  15. Temperature and SAR measurement errors in the evaluation of metallic linear structures heating during MRI using fluoroptic (registered) probes

    Energy Technology Data Exchange (ETDEWEB)

    Mattei, E [Department of Technologies and Health, Italian National Institute of Health, Rome (Italy); Triventi, M [Department of Technologies and Health, Italian National Institute of Health, Rome (Italy); Calcagnini, G [Department of Technologies and Health, Italian National Institute of Health, Rome (Italy); Censi, F [Department of Technologies and Health, Italian National Institute of Health, Rome (Italy); Kainz, W [Center for Devices and Radiological Health, Food and Drug Administration, Rockville, MD (United States); Bassen, H I [Center for Devices and Radiological Health, Food and Drug Administration, Rockville, MD (United States); Bartolini, P [Department of Technologies and Health, Italian National Institute of Health, Rome (Italy)

    2007-03-21

    The purpose of this work is to evaluate the error associated with temperature and SAR measurements using fluoroptic (registered) temperature probes on pacemaker (PM) leads during magnetic resonance imaging (MRI). We performed temperature measurements on pacemaker leads, excited with a 25, 64, and 128 MHz current. The PM lead tip heating was measured with a fluoroptic (registered) thermometer (Luxtron, Model 3100, USA). Different contact configurations between the pigmented portion of the temperature probe and the PM lead tip were investigated to find the contact position minimizing the temperature and SAR underestimation. A computer model was used to estimate the error made by fluoroptic (registered) probes in temperature and SAR measurement. The transversal contact of the pigmented portion of the temperature probe and the PM lead tip minimizes the underestimation for temperature and SAR. This contact position also has the lowest temperature and SAR error. For other contact positions, the maximum temperature error can be as high as -45%, whereas the maximum SAR error can be as high as -54%. MRI heating evaluations with temperature probes should use a contact position minimizing the maximum error, need to be accompanied by a thorough uncertainty budget and the temperature and SAR errors should be specified.

  16. Energy-depth relation of electrons in bulk targets by Monte-Carlo calculations

    International Nuclear Information System (INIS)

    Gaber, M.; Fitting, H.J.

    1984-01-01

    Monte-Carlo calculations are used to calculate the energy of penetrating electrons as a function of the depth in thick targets of Ti, Fe, Cu, As, In, and Au. It is shown that the mean energy ratio anti E(z)/E 0 decays exponentially with depth z and depends on the backscattering coefficient eta/sub B/ of the bulk material and the maximum range R(E 0 ) of the primary electrons with initial energy E 0 . Thereby a normalized plot anti E/E 0 as a function of the reduced depth z/R becomes possible. (author)

  17. An improved hand-held four-detector gamma-probe for radioassisted oncological surgery

    CERN Document Server

    Dusi, W; Bollini, D; Moroni, C; Ricard, M

    2000-01-01

    The performance of an improved intraoperative gamma-probe for radioassisted oncological surgery is presented and discussed. The probe is based on a square array of four 5x5 mm sup 2 coplanar CdTe room temperature semiconductor detectors and each detector has an independent read out electronic chain, allowing an original handling of the signal. Therefore, the search for gamma-emission hot points may be carried out in two different, independent ways: (1) Finding out the position of the probe corresponding to the maximum value of the total counting rate, on the basis of a trial and error procedure (typical for the conventional probe; (2) Finding out the position of the probe where both the differences between the counting rate performed by orthogonal, adjacent halves of the array vanish (differential method). This makes the new probe sensitive to the bidimensional gradient of the gamma-ray flux, measured on the scanned plane. Furthermore, the algebraic sign of the difference indicates in which direction the prob...

  18. A simple formula for depth dose calculation for Co-60 teletherapy beam dosimetry

    International Nuclear Information System (INIS)

    Tripathi, U.B.; Kelkar, N.Y.

    1979-01-01

    Knowledge of dose at all points of interest in the plane of tumour is essential for treatment planning. A very simple formula for scatter dose calculation along the central axis of a Co-60 beam has been derived. This formula uses primary dose at depth d, scatter air ratio at the depth of maximum ionisation and the effective depth of the volume, irradiating the medium. The method for calculation of percentage depth dose at any point in the principal plane has been explained in detail. The simple form of the formulation will help in improving the treatment plans for treatments of lesions using Co-60 teletherapy machines. (orig.) [de

  19. Influence of different frequencies and insertion depths on the diagnostic accuracy of liver elastography by acoustic radiation force impulse imaging (ARFI)

    Energy Technology Data Exchange (ETDEWEB)

    Potthoff, Andrej, E-mail: potthoff.andrej@mh-hannover.de [Department of Gastroenterology, Hepatology and Endocrinology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Attia, Dina; Pischke, Sven; Kirschner, Janina; Mederacke, Ingmar; Wedemeyer, Heiner; Manns, Michael P.; Gebel, Michael J.; Rifai, Kinan [Department of Gastroenterology, Hepatology and Endocrinology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany)

    2013-08-15

    Background: Acoustic Radiation Force Impulse Imaging (ARFI) is an innovative elastography for staging of liver fibrosis. We evaluated the diagnostic accuracy of different probes to perform ARFI at different insertion depths. Methods: In a prospective study, 89 chronic HCV infected patients underwent ARFI elastography using both available probes (c-ARFI: C4-1-MHz; l-ARFI: L9-4 MHz) in comparison to Fibroscan{sup ®}. Variability of ARFI elastography at different insertion depths was systematically evaluated in 39 patients (44%). According to Fibroscan{sup ®} elastography, 32 patients (36%) presented with liver cirrhosis, 23 patients (26%) had significant fibrosis and 34 patients (38%) had no significant fibrosis. Results: Mean propagation velocity with c-ARFI was 1.70 ± 0.67 m/s and 1.91 ± 0.87 m/s with l-ARFI. Results of both probes were correlated to each other (p < 0.001; r = 0.70) and to Fibroscan{sup ®} (p < 0.001, r = 0.82 and 0.84, respectively). In patients with significant fibrosis or with cirrhosis, mean values by l-ARFI were significantly higher than by c-ARFI (p < 0.001). For detection of liver cirrhosis, AUROC was 0.97 for c-ARFI (cut-off level 1.72 m/s) and 0.90 for l-ARFI (cut-off 2.04 m/s). Correlation coefficients of c-ARFI with Fibroscan{sup ®} were highest at an insertion depth of 5–6 cm (r = 0.882 and 0.864, respectively, p < 0.001) and at 3–4 cm for l-ARFI (r = 0.850 and 0.838, respectively, p < 0.001). Conclusions: ARFI elastography with the linear and with the convex probes showed comparable validity and accuracy in the estimation of liver stiffness. The linear probe gave higher ARFI values. The most accurate insertion depth was 5–6 cm for c-ARFI and 3–4 cm for l-ARFI indicating that measurements should not be performed close to the liver capsule.

  20. Distribution of phytoplankton groups within the deep chlorophyll maximum

    KAUST Repository

    Latasa, Mikel

    2016-11-01

    The fine vertical distribution of phytoplankton groups within the deep chlorophyll maximum (DCM) was studied in the NE Atlantic during summer stratification. A simple but unconventional sampling strategy allowed examining the vertical structure with ca. 2 m resolution. The distribution of Prochlorococcus, Synechococcus, chlorophytes, pelagophytes, small prymnesiophytes, coccolithophores, diatoms, and dinoflagellates was investigated with a combination of pigment-markers, flow cytometry and optical and FISH microscopy. All groups presented minimum abundances at the surface and a maximum in the DCM layer. The cell distribution was not vertically symmetrical around the DCM peak and cells tended to accumulate in the upper part of the DCM layer. The more symmetrical distribution of chlorophyll than cells around the DCM peak was due to the increase of pigment per cell with depth. We found a vertical alignment of phytoplankton groups within the DCM layer indicating preferences for different ecological niches in a layer with strong gradients of light and nutrients. Prochlorococcus occupied the shallowest and diatoms the deepest layers. Dinoflagellates, Synechococcus and small prymnesiophytes preferred shallow DCM layers, and coccolithophores, chlorophytes and pelagophytes showed a preference for deep layers. Cell size within groups changed with depth in a pattern related to their mean size: the cell volume of the smallest group increased the most with depth while the cell volume of the largest group decreased the most. The vertical alignment of phytoplankton groups confirms that the DCM is not a homogeneous entity and indicates groups’ preferences for different ecological niches within this layer.

  1. Contributions of depth filter components to protein adsorption in bioprocessing.

    Science.gov (United States)

    Khanal, Ohnmar; Singh, Nripen; Traylor, Steven J; Xu, Xuankuo; Ghose, Sanchayita; Li, Zheng J; Lenhoff, Abraham M

    2018-04-16

    Depth filtration is widely used in downstream bioprocessing to remove particulate contaminants via depth straining and is therefore applied to harvest clarification and other processing steps. However, depth filtration also removes proteins via adsorption, which can contribute variously to impurity clearance and to reduction in product yield. The adsorption may occur on the different components of the depth filter, that is, filter aid, binder, and cellulose filter. We measured adsorption of several model proteins and therapeutic proteins onto filter aids, cellulose, and commercial depth filters at pH 5-8 and ionic strengths filter component in the adsorption of proteins with different net charges, using confocal microscopy. Our findings show that a complete depth filter's maximum adsorptive capacity for proteins can be estimated by its protein monolayer coverage values, which are of order mg/m 2 , depending on the protein size. Furthermore, the extent of adsorption of different proteins appears to depend on the nature of the resin binder and its extent of coating over the depth filter surface, particularly in masking the cation-exchanger-like capacity of the siliceous filter aids. In addition to guiding improved depth filter selection, the findings can be leveraged in inspiring a more intentional selection of components and design of depth filter construction for particular impurity removal targets. © 2018 Wiley Periodicals, Inc.

  2. Investigating Surface and Interface Phenomena in LiFeBO3 Electrodes Using Photoelectron Spectroscopy Depth Profiling

    DEFF Research Database (Denmark)

    Maibach, Julia; Younesi, Reza; Schwarzburger, Nele

    2014-01-01

    The formation of surface and interface layers at the electrodes is highly important for the performance and stability of lithium ion batteries. To unravel the surface composition of electrode materials, photoelectron spectroscopy (PES) is highly suitable as it probes chemical surface and interface...... properties with high surface sensitivity. Additionally, by using synchrotron-generated hard x-rays as excitation source, larger probing depths compared to in-house PES can be achieved. Therefore, the combination of in-house soft x-ray photoelectron spectroscopy and hard x-ray photoelectron spectroscopy...

  3. Photoswitchable non-fluorescent thermochromic dye-nanoparticle hybrid probes

    OpenAIRE

    Harrington, Walter N.; Haji, Mwafaq R.; Galanzha, Ekaterina I.; Nedosekin, Dmitry A.; Nima, Zeid A.; Watanabe, Fumiya; Ghosh, Anindya; Biris, Alexandru S.; Zharov, Vladimir P.

    2016-01-01

    Photoswitchable fluorescent proteins with controllable light?dark states and spectral shifts in emission in response to light have led to breakthroughs in the study of cell biology. Nevertheless, conventional photoswitching is not applicable for weakly fluorescent proteins and requires UV light with low depth penetration in bio-tissue. Here we introduce a novel concept of photoswitchable hybrid probes consisting of thermochromic dye and absorbing nanoparticles, in which temperature-sensitive ...

  4. PZT Thin-Film Micro Probe Device with Dual Top Electrodes

    Science.gov (United States)

    Luo, Chuan

    Lead zirconate titanate (PZT) thin-film actuators have been studied intensively for years because of their potential applications in many fields. In this dissertation, a PZT thin-film micro probe device is designed, fabricated, studied, and proven to be acceptable as an intracochlear acoustic actuator. The micro probe device takes the form of a cantilever with a PZT thin-film diaphragm at the tip of the probe. The tip portion of the probe will be implanted in cochlea later in animal tests to prove its feasibility in hearing rehabilitation. The contribution of the dissertation is three-fold. First, a dual top electrodes design, consisting of a center electrode and an outer electrode, is developed to improve actuation displacement of the PZT thin-film diaphragm. The improvement by the dual top electrodes design is studied via a finite element model. When the dimensions of the dual electrodes are optimized, the displacement of the PZT thin-film diaphragm increases about 30%. A PZT thin-film diaphragm with dual top electrodes is fabricated to prove the concept, and experimental results confirm the predictions from the finite element analyses. Moreover, the dual electrode design can accommodate presence of significant residual stresses in the PZT thin-film diaphragm by changing the phase difference between the two electrodes. Second, a PZT thin-film micro probe device is fabricated and tested. The fabrication process consists of PZT thin-film deposition and deep reactive ion etching (DRIE). The uniqueness of the fabrication process is an automatic dicing mechanism that allows a large number of probes to be released easily from the wafer. Moreover, the fabrication is very efficient, because the DRIE process will form the PZT thin-film diaphragm and the special dicing mechanism simultaneously. After the probes are fabricated, they are tested with various possible implantation depths (i.e., boundary conditions). Experimental results show that future implantation depths

  5. Ultra-shallow junction (USJ) sheet resistance measurements with a non-penetrating four point probe

    International Nuclear Information System (INIS)

    Benjamin, M.C.; Hillard, R.J.; Borland, J.O.

    2005-01-01

    An accurate method to measure the four point probe (4PP) sheet resistance (R S ) of ultra shallow junction (USJ) Source-Drain Extension structures is described. The method utilizes Elastic Material probes (EM-probes) to form non-penetrating contacts to the silicon surface [R.J. Hillard, P.Y. Hung, William Chism, C. Win Ye, W.H. Howland, L.C. Tan, C.E. Kalnas, Characterization and Metrology for ULSI Technology, AIP Conference proceedings 683 (2003) 802.]. The probe design is kinematic and the force is controlled to ensure elastic deformation of the probe material. The probe material is such that large direct tunneling currents can flow through the native oxide thereby forming a low impedance contact. Sheet resistance measurements on USJ implanted P+/N structures with Secondary Ion Mass Spectroscopy (SIMS) junction depths less than 15 nm have been measured. The method is demonstrated on implanted USJ structures and found to be consistent with expectations

  6. Development of a combined OCT-Raman probe for the prospective in vivo clinical melanoma skin cancer screening

    Science.gov (United States)

    Mazurenka, M.; Behrendt, L.; Meinhardt-Wollweber, M.; Morgner, U.; Roth, B.

    2017-10-01

    A combined optical coherence tomography (OCT)-Raman probe was designed and built into a spectral domain OCT head, and its performance was evaluated and compared to the most common Raman probe setups, based on a fiber bundle and confocal free space optics. Due to the use of the full field of view of an OCT scanning lens, the combined probe has a superior performance within maximum permissible exposure limits, compared to the other two probes. Skin Raman spectra, recorded in vivo, further prove the feasibility of the OCT-Raman probe for the future in vivo clinical applications in skin cancer screening.

  7. SU-E-T-610: Phosphor-Based Fiber Optic Probes for Proton Beam Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Darafsheh, A; Soldner, A; Liu, H; Kassaee, A; Zhu, T; Finlay, J [Univ Pennsylvania, Philadelphia, PA (United States)

    2015-06-15

    Purpose: To investigate feasibility of using fiber optics probes with rare-earth-based phosphor tips for proton beam radiation dosimetry. We designed and fabricated a fiber probe with submillimeter resolution (<0.5 mm3) based on TbF3 phosphors and evaluated its performance for measurement of proton beam including profiles and range. Methods: The fiber optic probe with TbF3 phosphor tip, embedded in tissue-mimicking phantoms was irradiated with double scattering proton beam with energy of 180 MeV. Luminescence spectroscopy was performed by a CCD-coupled spectrograph to analyze the emission spectra of the fiber tip. In order to measure the spatial beam profile and percentage depth dose, we used singular value decomposition method to spectrally separate the phosphors ionoluminescence signal from the background Cerenkov radiation signal. Results: The spectra of the TbF3 fiber probe showed characteristic ionoluminescence emission peaks at 489, 542, 586, and 620 nm. By using singular value decomposition we found the contribution of the ionoluminescence signal to measure the percentage depth dose in phantoms and compared that with measurements performed with ion chamber. We observed quenching effect at the spread out Bragg peak region, manifested as under-responding of the signal, due to the high LET of the beam. However, the beam profiles were not dramatically affected by the quenching effect. Conclusion: We have evaluated the performance of a fiber optic probe with submillimeter resolution for proton beam dosimetry. We demonstrated feasibility of spectral separation of the Cerenkov radiation from the collected signal. Such fiber probes can be used for measurements of proton beams profile and range. The experimental apparatus and spectroscopy method developed in this work provide a robust platform for characterization of proton-irradiated nanophosphor particles for ultralow fluence photodynamic therapy or molecular imaging applications.

  8. A new XRF probe for in-situ determining concentration of multi-elements in ocean sediments

    CERN Document Server

    Ge Liang Quan; Zhou Si Chun; Lin Ling; Lin Yan Chang; Ren Jia Fu

    2001-01-01

    The author introduces a new X-ray fluorescence probe for in-situ determining the concentration of multi-elements in ocean sediments. The probe consists of Si-Pin X-ray detector with an electro-thermal colder, two isotope sources, essential electrical signal processing units and a notebook computer. More than 10 elements can be simultaneously determined at a detection limit of (10-200) x 10 sup - sup 6 and precision of 5%-30% without liquid Nitrogen supply. tests show that the probe can perform the analytical tasks under the water at the depth of less than 1000 meters

  9. Development of Ultrasonic Modulation Probe for Fluorescence Tomography Based on Acousto-Optic Effect

    Directory of Open Access Journals (Sweden)

    Trinh Quang Duc

    2011-01-01

    Full Text Available We have developed an ultrasonic probe for fluorescence modulation to image fluorescence within biological tissues. The probe consists of a focused ultrasonic transducer mounted on actuators for mechanical fan scanning, which can be used in contact with the measuring object aiming for clinical application. The mechanical fan scanning employed in the probe has a beneficial feature of portability. As a result, fluorescent beads, which were localized with the diameter of 2 mm at 20 mm depth in a pork meat tissue, were detected with resolution of 3 mm. The system performance denotes the feasibility of development towards the final goal of ultrasonic fluorescence modulation tomography for clinical applications.

  10. Deuterium depth profiles in metals using imaging field desorption

    International Nuclear Information System (INIS)

    Panitz, J.A.

    1976-01-01

    Depth profiles of 80 eV deuterium ions implanted in-situ into (110) tungsten have been measured by Imaging, Field-Desorption Mass Spectrometry. The relative abundance of deuterium was measured from the surface to a depth of 300A with less than 3A depth resolution by controlled field-evaporation of the specimen, and time-of-flight mass spectroscopy. The position of the depth distribution maximum (57 +- 3A from the surface) is shown to be in close agreement with that predicted theoretically for low energy deuterium implants using an amorphous-solid model. Structure in the distribution is attributed to surface morphology and channeling phenomena in the near surface region. Implanted impurity species from the ion source and tungsten surface have also been observed. For C + , C 2+ and 0 + , penetration is limited to less than 30A, with abundance decreasing exponentially from the surface. These results are interpreted in the context of the CTR first-wall impurity problem, and are used to suggest a novel method for in-situ characterization of low energy plasma species in operating CTR devices

  11. Method for Predicting Void Ratio and Triaxial Friction Angle from Laboratory CPT at Shallow Depths

    DEFF Research Database (Denmark)

    Larsen, Kim André; Ibsen, Lars Bo

    In this report an investigation of the relationship between the tip resistance, qc of a laboratory CPT-probe versus the relative density, Dr and friction angle, ∏ of Aalborg University Sand No. 0 is carried out. A method for estimating the relative density and the triaxial friction angle from...... the cone resistance of the laboratory probe is proposed. The suggested method deals with the fact that the friction angle is depended of the stress level especially at low stresses. The method includes a calibration of the cone resistance from the laboratory CPT at shallow depths i.e. low values of d...

  12. Studies of impurity recycling by the collector probe technique

    International Nuclear Information System (INIS)

    Hildebrandt, D.; Grote, H.; Herrmann, A.; Laux, M.; Pech, P.; Reiner, H.D.; Wolff, H.

    1987-01-01

    In order to study recycling effects of the nonintrinsic impurity Li discharges with and without LiD-pellet injection were investigated. The observed maximum impurity level of Li in the SOL plasma of discharges without injection reaches less than 10% of that observed in discharges with injection. The measurements offer the possibility to distinguish between influxes from the wall and those which reach the collector probe via the core plasma. The time evolution, orientation and radial dependence of the impurity fluxes are characteristic features of their origin. The consideration of all these features facilitates a better understanding of collector probe measurements in the SOL-plasma. (orig.)

  13. Soil gas measurements at high permeabilities and below foundation depth

    International Nuclear Information System (INIS)

    Johner, H.U; Surbeck, H.

    2000-01-01

    We started a project of soil gas measurements beneath houses. Since the foundations of houses often lie deeper than 0.5 to 1 m - the depth where soil gas measurements are often made - the first approach was to apply the method developed previously to deeper soil layers. The radon availability index (RAI), which was defined empirically, proved to be a reliable indicator for radon problems in nearby houses. The extreme values of permeability, non-Darcy flow and scale dependence of permeability stimulated the development of a multi-probe method. A hydrological model was applied to model the soil gas transport. The soil gas measurements below foundation depth provided a wealth of new information. A good classification of soil properties could be achieved. If soil gas measurements are to be made, the low permeability layer has to be traversed. A minimum depth of 1 .5 m is suggested, profiles to below the foundation depth are preferable. There are also implications for mitigation works. A sub-slab suction system should reach the permeable layer to function well. This also holds for radon wells. If a house is located on a slope, it is most convenient to install the sub-slab suction system on the hillside, as the foundation reaches the deepest levels there

  14. Efficient oligonucleotide probe selection for pan-genomic tiling arrays

    Directory of Open Access Journals (Sweden)

    Zhang Wei

    2009-09-01

    Full Text Available Abstract Background Array comparative genomic hybridization is a fast and cost-effective method for detecting, genotyping, and comparing the genomic sequence of unknown bacterial isolates. This method, as with all microarray applications, requires adequate coverage of probes targeting the regions of interest. An unbiased tiling of probes across the entire length of the genome is the most flexible design approach. However, such a whole-genome tiling requires that the genome sequence is known in advance. For the accurate analysis of uncharacterized bacteria, an array must query a fully representative set of sequences from the species' pan-genome. Prior microarrays have included only a single strain per array or the conserved sequences of gene families. These arrays omit potentially important genes and sequence variants from the pan-genome. Results This paper presents a new probe selection algorithm (PanArray that can tile multiple whole genomes using a minimal number of probes. Unlike arrays built on clustered gene families, PanArray uses an unbiased, probe-centric approach that does not rely on annotations, gene clustering, or multi-alignments. Instead, probes are evenly tiled across all sequences of the pan-genome at a consistent level of coverage. To minimize the required number of probes, probes conserved across multiple strains in the pan-genome are selected first, and additional probes are used only where necessary to span polymorphic regions of the genome. The viability of the algorithm is demonstrated by array designs for seven different bacterial pan-genomes and, in particular, the design of a 385,000 probe array that fully tiles the genomes of 20 different Listeria monocytogenes strains with overlapping probes at greater than twofold coverage. Conclusion PanArray is an oligonucleotide probe selection algorithm for tiling multiple genome sequences using a minimal number of probes. It is capable of fully tiling all genomes of a species on

  15. Pulsed-laser atom-probe field-ion microscopy

    International Nuclear Information System (INIS)

    Kellogg, G.L.; Tsong, T.T.

    1980-01-01

    A time-of-flight atom-probe field-ion microscope has been developed which uses nanosecond laser pulses to field evaporate surface species. The ability to operate an atom-probe without using high-voltage pulses is advantageous for several reasons. The spread in energy arising from the desorption of surface species prior to the voltage pulse attaining its maximum amplitude is eliminated, resulting in increased mass resolution. Semiconductor and insulator samples, for which the electrical resistivity is too high to transmit a short-duration voltage pulse, can be examined using pulsed-laser assisted field desorption. Since the electric field at the surface can be significantly smaller, the dissociation of molecular adsorbates by the field can be reduced or eliminated, permitting well-defined studies of surface chemical reactions. In addition to atom-probe operation, pulsed-laser heating of field emitters can be used to study surface diffusion of adatoms and vacancies over a wide range of temperatures. Examples demonstrating each of these advantages are presented, including the first pulsed-laser atom-probe (PLAP) mass spectra for both metals (W, Mo, Rh) and semiconductors (Si). Molecular hydrogen, which desorbs exclusively as atomic hydrogen in the conventional atom probe, is shown to desorb undissociatively in the PLAP. Field-ion microscope observations of the diffusion and dissociation of atomic clusters, the migration of adatoms, and the formation of vacancies resulting from heating with a 7-ns laser pulse are also presented

  16. The selection of ultrasonic transducers for inspection of pipeline girth welds. Vol. 2. Evaluation of a unique creeping wave probe for examination of the cap region in pipeline girth welds

    Energy Technology Data Exchange (ETDEWEB)

    Fingerhut, M P; Glover, A G; Dorling, D V

    1988-10-01

    This work is part of a program aimed at developing an ultrasonic inspection design for the nondestructive evaluation of pipeline girth welds made by the mechanized gas metal arc (GMA) welding process for onshore and offshore pipeline construction. The feasibility of using creeping waves for examination of the cap region was investigated and, as a result, a specification for an experimental creeping wave transducer developed and a probe was designed to provide a beam oriented nearly perpendicular to expected defects in the cap region of the weld. The performance of this experimental creeping wave transducer was evaluated with respect to its ability to detect simulated and real weld defects in the cap region of mechanized GMA welds in 9.5 mm material. The probe was successful in detecting planar lack of sidewall fusion welding defects with a signal-to-noise ratio of greater than 12 dB, at depths of up to 4.2 mm from the plate surface. This indicates maximum pipe wall thicknesses of 10.9 mm may be satisfactorily examined before additional probes are required, assuming complete coverage in the root region is provided by other probes. The creeping wave probe not only performed well in the detection of real weld defects in the cap region for which it was intended, but also showed potential for detecting and discriminating some planar defects in the root region. 9 refs., 23 figs., 3 tabs.

  17. Depth enhancement of S3D content and the psychological effects

    Science.gov (United States)

    Hirahara, Masahiro; Shiraishi, Saki; Kawai, Takashi

    2012-03-01

    Stereoscopic 3D (S3D) imaging technologies are widely used recently to create content for movies, TV programs, games, etc. Although S3D content differs from 2D content by the use of binocular parallax to induce depth sensation, the relationship between depth control and the user experience remains unclear. In this study, the user experience was subjectively and objectively evaluated in order to determine the effectiveness of depth control, such as an expansion or reduction or a forward or backward shift in the range of maximum parallactic angles in the cross and uncross directions (depth bracket). Four types of S3D content were used in the subjective and objective evaluations. The depth brackets of comparison stimuli were modified in order to enhance the depth sensation corresponding to the content. Interpretation Based Quality (IBQ) methodology was used for the subjective evaluation and the heart rate was measured to evaluate the physiological effect. The results of the evaluations suggest the following two points. (1) Expansion/reduction of the depth bracket affects preference and enhances positive emotions to the S3D content. (2) Expansion/reduction of the depth bracket produces above-mentioned effects more notable than shifting the cross/uncross directions.

  18. Depth Estimates for Slingram Electromagnetic Anomalies from Dipping Sheet-like Bodies by the Normalized Full Gradient Method

    Science.gov (United States)

    Dondurur, Derman

    2005-11-01

    The Normalized Full Gradient (NFG) method was proposed in the mid 1960s and was generally used for the downward continuation of the potential field data. The method eliminates the side oscillations which appeared on the continuation curves when passing through anomalous body depth. In this study, the NFG method was applied to Slingram electromagnetic anomalies to obtain the depth of the anomalous body. Some experiments were performed on the theoretical Slingram model anomalies in a free space environment using a perfectly conductive thin tabular conductor with an infinite depth extent. The theoretical Slingram responses were obtained for different depths, dip angles and coil separations, and it was observed from NFG fields of the theoretical anomalies that the NFG sections yield the depth information of top of the conductor at low harmonic numbers. The NFG sections consisted of two main local maxima located at both sides of the central negative Slingram anomalies. It is concluded that these two maxima also locate the maximum anomaly gradient points, which indicates the depth of the anomaly target directly. For both theoretical and field data, the depth of the maximum value on the NFG sections corresponds to the depth of the upper edge of the anomalous conductor. The NFG method was applied to the in-phase component and correct depth estimates were obtained even for the horizontal tabular conductor. Depth values could be estimated with a relatively small error percentage when the conductive model was near-vertical and/or the conductor depth was larger.

  19. Spatial resolution in depth-controlled surface sensitive x-ray techniques

    International Nuclear Information System (INIS)

    Yun, W.B.; Viccaro, P.J.

    1992-01-01

    The spatial resolution along the surface normal and the total depth probed are two important parameters in depth-controlled surface sensitive X-ray techniques employing grazing incidence geometry. The two parameters are analyzed in terms of optical properties (refractive indices) of the media involved and parameters of the incident X-ray beam: beam divergence, X-ray energy, and spectral bandwidth. We derive analytical expressions of the required beam divergence and spectral bandwidth of the incident beam as a function of the two parameters. Sample calculations are made for X-ray energies between 0.1 and 100 keV and for solid Be, Cu, and Au, representing material matrices consisting of low, medium, and high atomic number elements. A brief discussion on obtaining the required beam divergence and spectral bandwidth from present X-ray sources and optics is given

  20. The use of small diameter probing equipment for contaminated site investigation

    International Nuclear Information System (INIS)

    Christy, T.M.; Spradlin, S.C.

    1992-01-01

    The past decade has witnessed a dramatic increase in the number of contaminated sites being investigated in the United States. This increase in subsurface investigation has spurred a corresponding increase in the development of subsurface sampling tools and methods. The past five years, in particular, have seen the development of small diameter (1 double-prime to 1.4 double-prime O.D.) percussion driven probing tools which can be used for the recovery of soil vapor, soil core and groundwater samples. This development has placed heretofore unavailable tools at the disposal of site investigators. Mechanized, vehicle mounted soil probe systems apply both static force and hydraulically powered percussion hammers for tool placement. Static down forces up to 3,000 lbs combined with percussion hammers of eight (8) horsepower continuous output are typical on equipment available to the field investigator. Using these energies, probing tools have been used for sampling a variety of media at depths exceeding 70 feet. Advantages of probing equipment which have contributed to its increasing usage in recent years include: ease of mobilization, absence of borehole cuttings, minimization of surface disturbance, and speed of sample collection. This paper focuses on the field application of hydraulic probing equipment including: the suitability of probing operations with respect to various Boil types and lithologies to probing operations; sampler types and recovery quantities for various media, and innovative probing applications presently being tested

  1. A Water Temperature Simulation Model for Rice Paddies With Variable Water Depths

    Science.gov (United States)

    Maruyama, Atsushi; Nemoto, Manabu; Hamasaki, Takahiro; Ishida, Sachinobu; Kuwagata, Tsuneo

    2017-12-01

    A water temperature simulation model was developed to estimate the effects of water management on the thermal environment in rice paddies. The model was based on two energy balance equations: for the ground and for the vegetation, and considered the water layer and changes in the aerodynamic properties of its surface with water depth. The model was examined with field experiments for water depths of 0 mm (drained conditions) and 100 mm (flooded condition) at two locations. Daily mean water temperatures in the flooded condition were mostly higher than in the drained condition in both locations, and the maximum difference reached 2.6°C. This difference was mainly caused by the difference in surface roughness of the ground. Heat exchange by free convection played an important role in determining water temperature. From the model simulation, the temperature difference between drained and flooded conditions was more apparent under low air temperature and small leaf area index conditions; the maximum difference reached 3°C. Most of this difference occurred when the range of water depth was lower than 50 mm. The season-long variation in modeled water temperature showed good agreement with an observation data set from rice paddies with various rice-growing seasons, for a diverse range of water depths (root mean square error of 0.8-1.0°C). The proposed model can estimate water temperature for a given water depth, irrigation, and drainage conditions, which will improve our understanding of the effect of water management on plant growth and greenhouse gas emissions through the thermal environment of rice paddies.

  2. Study on particle behavior in the expansion of fluidized bed using a simple optical probe. Kogaku probe wo mochiita ryudoso no bocho sonai ryushi kyodo ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Y; Miyamoto, M [Yamaguchi University, Yamaguchi (Japan). Faculty of Engineering; Chimura, T [Toyota Motor Co. Ltd., Tokyo (Japan); Idei, Y [Ube Industries, Ltd., Tokyo (Japan)

    1991-09-25

    In order to clarify the relationship between the heat transfer rate and the expansion bed in a group of horizontal pipes in a freeboard region (an area of the heat-transfer pipe exposed above the height of static particle bed from the beginning) in a cold model of the fluidized bed, particle behavior was measured using an optical measuring method. The light axis position was set higher than the heat-transfer as X {sub p} in a direction perpendicular from the distributor, and the static bed height was set to L {sub c}. The frequency of particles and particle lumps coming to presence between the light axes is termed V {prime}{sub p}(time-averaged dimensionless amount of the optical probe output). The V {prime}{sub p} decreases with an increase in the flow velocity, and, when the difference between the probe tip and the static bed height, X {sub p}{minus} L {sub c} is small, it shows the minimum value at a certain flow velocity and then rises again. The root mean square value of the probe output, V {prime}{sub f} increased with an increase in the flow velocity, reached its maximum, then decreased to the minimum, and rose again. The flow velocity that takes the maximum heat transfer rate can be identified from the relationship among the dimensionless amount of the maximum expansion bed height and the average expansion bed height, the dimensionless height of X {sub p} when V {prime}{sub p} and V {prime}{sub f} obtained at each X {sub p} show the extreme values, and the dimensionless height of the heat-transfer pipes when the average transfer rate takes the maximum value. 6 refs., 5 figs.

  3. Microbial diversity from chlorophyll maximum, oxygen minimum and bottom zones in the southwestern Atlantic Ocean

    Science.gov (United States)

    Medina-Silva, Renata; de Oliveira, Rafael R.; Pivel, Maria A. G.; Borges, Luiz G. A.; Simão, Taiz L. L.; Pereira, Leandro M.; Trindade, Fernanda J.; Augustin, Adolpho H.; Valdez, Fernanda P.; Eizirik, Eduardo; Utz, Laura R. P.; Groposo, Claudia; Miller, Dennis J.; Viana, Adriano R.; Ketzer, João M. M.; Giongo, Adriana

    2018-02-01

    Conspicuous physicochemical vertical stratification in the deep sea is one of the main forces driving microbial diversity in the oceans. Oxygen and sunlight availability are key factors promoting microbial diversity throughout the water column. Ocean currents also play a major role in the physicochemical stratification, carrying oxygen down to deeper zones as well as moving deeper water masses up towards shallower depths. Water samples within a 50-km radius in a pockmark location of the southwestern Atlantic Ocean were collected and the prokaryotic communities from different water depths - chlorophyll maximum, oxygen minimum and deep-sea bottom (down to 1355 m) - were described. At phylum level, Proteobacteria were the most frequent in all water depths, Cyanobacteria were statistically more frequent in chlorophyll maximum zone, while Thaumarchaeota were significantly more abundant in both oxygen minimum and bottom waters. The most frequent microorganism in the chlorophyll maximum and oxygen minimum zones was a Pelagibacteraceae operational taxonomic unit (OTU). At the bottom, the most abundant genus was the archaeon Nitrosopumilus. Beta diversity analysis of the 16S rRNA gene sequencing data uncovered in this study shows high spatial heterogeneity among water zones communities. Our data brings important contribution for the characterisation of oceanic microbial diversity, as it consists of the first description of prokaryotic communities occurring in different oceanic water zones in the southwestern Atlantic Ocean.

  4. Inspection of welded zone and flat plate using flexible ECA probe

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Jun; Lee, Kyu Sung; Shin, Chung Ho; Lee, Kyoung Jun; Jang, Yoon Young [ANSCO Inc., Daejeon (Korea, Republic of)

    2016-08-15

    This paper aims to compare the ability to detect notch defects existing in the plate and welded area using a flexible ECA (eddy current array) probe with OmniScan MX and MS-5800E. The characteristics of signals with various frequencies and lift-offs were also compared. As a result, when signals of frequencies 500, 1000, and 1500 kHz were used, the amplitude of the signal increased, as the depth of the notch increased, but reduced linearly in accordance with the lift-off variation. In addition, the detection sensitivity of the weld defect was found to be closely related to the contact surface of the probe and specimen. In this paper, it was demonstrated that the detection sensitivity was excellent when the contact surface of the probe and the specimen was sufficient, but it was poor when the contact surface was insufficient.

  5. Development of Compact, Modular Lunar Heat Flow Probes

    Science.gov (United States)

    Nagihara, S.; Zacny, K.; Hedlund, M.; Taylor, P. T.

    2014-01-01

    Geothermal heat flow measurements are a high priority for the future lunar geophysical network missions recommended by the latest Decadal Survey and previously the International Lunar Network. Because the lander for such a mission will be relatively small, the heat flow instrumentation must be a low-mass and low-power system. The instrument needs to measure both thermal gradient and thermal conductivity of the regolith penetrated. It also needs to be capable of excavating a deep enough hole (approx. 3 m) to avoid the effect of potential long-term changes of the surface thermal environment. The recently developed pneumatic excavation system can largely meet the low-power, low-mass, and the depth requirements. The system utilizes a stem which winds out of a pneumatically driven reel and pushes its conical tip into the regolith. Simultaneously, gas jets, emitted from the cone tip, loosen and blow away the soil. The thermal sensors consist of resistance temperature detectors (RTDs) embedded on the stem and an insitu thermal conductivity probe attached to the cone tip. The thermal conductivity probe consists of a short 'needle' (2.4-mm diam. and 15- to 20-mm length) that contains a platinum RTD wrapped in a coil of heater wire. During a deployment, when the penetrating cone reaches a desired depth, it stops blowing gas, and the stem pushes the needle into the yet-to-be excavated, undisturbed bottom soil. Then, it begins heating and monitors the temperature. Thermal conductivity of the soil can determined from the rate of temperature increase with time. When the measurement is complete, the system resumes excavation until it reaches the next targeted depth.

  6. Neuro-fuzzy GMDH based particle swarm optimization for prediction of scour depth at downstream of grade control structures

    Directory of Open Access Journals (Sweden)

    Mohammad Najafzadeh

    2015-03-01

    Full Text Available In the present study, neuro-fuzzy based-group method of data handling (NF-GMDH as an adaptive learning network was utilized to predict the maximum scour depth at the downstream of grade-control structures. The NF-GMDH network was developed using particle swarm optimization (PSO. Effective parameters on the scour depth include sediment size, geometry of weir, and flow characteristics in the upstream and downstream of structure. Training and testing of performances were carried out using non-dimensional variables. Datasets were divided into three series of dataset (DS. The testing results of performances were compared with the gene-expression programming (GEP, evolutionary polynomial regression (EPR model, and conventional techniques. The NF-GMDH-PSO network produced lower error of the scour depth prediction than those obtained using the other models. Also, the effective input parameter on the maximum scour depth was determined through a sensitivity analysis.

  7. Nuclear probes in physical and geochemical studies of natural diamonds

    International Nuclear Information System (INIS)

    Sellschop, J.P.F.

    In this review the emphasis is directed to the use of nuclear particles for the analysis of impurities in diamond from an interest in both the observed physical properties and genesis of diamond and the inter-relation between these two aspects. However (nuclear) radiation can be used more specifically: from the inter-relation of elemental impurities chemical and geochemical information can be deduced, from energy variation depth distributions of selected impurities can be determined, the prospect of lattice location of impurities exists from the use of extremely finely collimated beams of nuclear particles, which are used also for probing the inter-atomic fields, and finally all nuclear probes excite luminescence in diamonds

  8. Contact mechanics of reverse total shoulder arthroplasty during abduction: the effect of neck-shaft angle, humeral cup depth, and glenosphere diameter.

    Science.gov (United States)

    Langohr, G Daniel G; Willing, Ryan; Medley, John B; Athwal, George S; Johnson, James A

    2016-04-01

    Implant design parameters can be changed during reverse shoulder arthroplasty (RSA) to improve range of motion and stability; however, little is known regarding their impact on articular contact mechanics. The purpose of this finite element study was to investigate RSA contact mechanics during abduction for different neck-shaft angles, glenosphere sizes, and polyethylene cup depths. Finite element RSA models with varying neck-shaft angles (155°, 145°, 135°), sizes (38 mm, 42 mm), and cup depths (deep, normal, shallow) were loaded with 400 N at physiological abduction angles. The contact area and maximum contact stress were computed. The contact patch and the location of maximum contact stress were typically located inferomedially in the polyethylene cup. On average for all abduction angles investigated, reducing the neck-shaft angle reduced the contact area by 29% for 155° to 145° and by 59% for 155° to 135° and increased maximum contact stress by 71% for 155° to 145° and by 286% for 155° to 135°. Increasing the glenosphere size increased the contact area by 12% but only decreased maximum contact stress by 2%. Decreasing the cup depth reduced the contact area by 40% and increased maximum contact stress by 81%, whereas increasing the depth produced the opposite effect (+52% and -36%, respectively). The location of the contact patch and maximum contact stress in this study matches the area of damage seen frequently on clinical retrievals. This finding suggests that damage to the inferior cup due to notching may be potentiated by contact stresses. Increasing the glenosphere diameter improved the joint contact area and did not affect maximum contact stress. However, although reducing the neck-shaft angle and cup depth can improve range of motion, our study shows that this also has some negative effects on RSA contact mechanics, particularly when combined. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc

  9. Turbulence Measurements from a Moored Platform at Mid-Depth in a Swift Tidal Channel

    Science.gov (United States)

    Hay, Alex; Lueck, Rolf; Wolk, Fabian; McMillan, Justine

    2014-05-01

    Results are presented from a turbulence experiment with a 3-m long streamlined floatation body, instrumented with velocity shear probes, fast-response thermistors, a 1 MHz Acoustic Doppler Current Profiler (AD2CP), and an Acoustic Doppler Velocimeter (ADV). The system was deployed over seven tidal cycles at mid-depth in a 30-m deep tidal channel in the lower Bay of Fundy, Canada. Peak flow speeds exceeded 2 m s-1, and while 10-min time scale average speeds were similar between ebb and flood, the variances were markedly higher during flood. Turbulent kinetic energy (TKE) dissipation rates measured with the shear probes exhibit a pronounced flood/ebb contrast: O(10-4) W kg-1 peak values during flood, but lower by an order of magnitude during ebb. Dissipation rates follow u3 scaling over a wide range of flow speeds between 0.5 and 2.5 m s-1. Below 0.5 m s-1 an asymmetry in the mounting arrangement caused the floatation body to pitch upward, biasing the measured dissipation values high. The ADV on the platform registered mean speed - used to implement Taylor's hypothesis - which was corroborated with the platform-mounted ADCP. Additional ADCPs were also deployed on a nearby bottom pod, sampling at turbulence resolving rates - up to 8 Hz. Comparisons between the shear probe and acoustic estimates of the TKE spectrum and dissipation rate - at comparable depths - are presented.

  10. Multipoint Observations of Energetic Particle Injections and Substorm Activity During a Conjunction Between Magnetospheric Multiscale (MMS) and Van Allen Probes

    Science.gov (United States)

    Turner, D. L.; Fennell, J. F.; Blake, J. B.; Claudepierre, S. G.; Clemmons, J. H.; Jaynes, A. N.; Leonard, T.; Baker, D. N.; Cohen, I. J.; Gkioulidou, M.; Ukhorskiy, A. Y.; Mauk, B. H.; Gabrielse, C.; Angelopoulos, V.; Strangeway, R. J.; Kletzing, C. A.; Le Contel, O.; Spence, H. E.; Torbert, R. B.; Burch, J. L.; Reeves, G. D.

    2017-11-01

    This study examines multipoint observations during a conjunction between Magnetospheric Multiscale (MMS) and Van Allen Probes on 7 April 2016 in which a series of energetic particle injections occurred. With complementary data from Time History of Events and Macroscale Interactions during Substorms, Geotail, and Los Alamos National Laboratory spacecraft in geosynchronous orbit (16 spacecraft in total), we develop new insights on the nature of energetic particle injections associated with substorm activity. Despite this case involving only weak substorm activity (maximum AE energy wave activity is also established from Van Allen Probes and MMS. Drift mapping using a simplified magnetic field model provides estimates of the dispersionless injection boundary locations as a function of universal time, magnetic local time, and L shell. The analysis reveals that at least five electron injections, which were localized in magnetic local time, preceded a larger injection of both electrons and ions across nearly the entire nightside of the magnetosphere near geosynchronous orbit. The larger ion and electron injection did not penetrate to L < 6.6, but several of the smaller electron injections penetrated to L < 6.6. Due to the discrepancy between the number, penetration depth, and complexity of electron versus ion injections, this event presents challenges to the current conceptual models of energetic particle injections.

  11. Molecular engineering of two-photon fluorescent probes for bioimaging applications

    Science.gov (United States)

    Liu, Hong-Wen; Liu, Yongchao; Wang, Peng; Zhang, Xiao-Bing

    2017-03-01

    During the past two decades, two-photon microscopy (TPM), which utilizes two near-infrared photons as the excitation source, has emerged as a novel, attractive imaging tool for biological research. Compared with one-photon microscopy, TPM offers several advantages, such as lowering background fluorescence in living cells and tissues, reducing photodamage to biosamples, and a photobleaching phenomenon, offering better 3D spatial localization, and increasing penetration depth. Small-molecule-based two-photon fluorescent probes have been well developed for the detection and imaging of various analytes in biological systems. In this review, we will give a general introduction of molecular engineering of two-photon fluorescent probes based on different fluorescence response mechanisms for bioimaging applications during the past decade. Inspired by the desired advantages of small-molecule two-photon fluorescent probes in biological imaging applications, we expect that more attention will be devoted to the development of new two-photon fluorophores and applications of TPM in areas of bioanalysis and disease diagnosis.

  12. In situ neutron depth profiling: A powerful method to probe lithium transport in micro-batteries

    NARCIS (Netherlands)

    Oudenhoven, J.F.M.; Labohm, F.; Mulder, M.; Niessen, R.A.H.; Mulder, F.M.; Notten, P.H.L.

    2011-01-01

    In situ neutron depth profiling (NDP) offers the possibility to observe lithium transport inside micro-batteries during battery operation. It is demonstrated that NDP results are consistent with the results of electrochemical measurements, and that the use of an enriched6LiCoO2 cathode offers more

  13. Characterization of axial probes used in eddy current testing

    International Nuclear Information System (INIS)

    Wache, G.; Nourrisson, Ph.; Garet, Th.

    2001-01-01

    Customized reference tubes reduced sensitivity discrepancies able to be observed from one probe to the other, due to the gain setting adjustment required for a pre-definite level in amplitude response of the artificial notch. The use of a reference circuit in place of a reference part, makes characterization of the probe matched to its generator more accurate: - the material dependence is cancelled during the compensation process, - the reference signal can be adjusted more accurately in amplitude and phase response, - the manufacturing cost is reduced compared to the one necessary for machining the reference part, - the amplitude and phase response of the reference circuit can be simply modelled by using the transformer relations, such as one can appreciate the variations of the probe definition parameters and its connexion to the generator, and makes them optimal for use. The method proposed by ALSTOM for the characterization of the condenser and exchanger tubing probes, takes in account the amplitude and phase response of a reference circuit versus frequency, such it can be done by using SURECA tubing provided by ASCOT: it allows to control that the frequency values of the probe required for use are inside the useful bandwidth defined by the - 6 dB attenuation from the maximum amplitude response of the reference circuit versus frequency. Examples coming from measurements done among more than 200 probes, for which faults have been observed and replacements made by the manufacturer, are displayed and commented. (authors)

  14. Synthesis and application of a highly selective copper ions fluorescent probe based on the coumarin group

    Science.gov (United States)

    He, Guangjie; Liu, Xiangli; Xu, Jinhe; Ji, Liguo; Yang, Linlin; Fan, Aiying; Wang, Songjun; Wang, Qingzhi

    2018-02-01

    A highly selective copper ions fluorescent probe based on the coumarin-type Schiff base derivative 1 (probe) was produced by condensation reaction between coumarin carbohydrazide and 1H-indazole-3-carbaldehyde. The UV-vis spectroscopy showed that the maximum absorption peak of compound 1 appeared at 439 nm. In the presence of Cu2 + ions, the maximum peak decreased remarkably compared with other physiological important metal ions and a new absorption peak at 500 nm appeared. The job's plot experiments showed that complexes of 1:2 binding mode were formed in CH3CN:HEPES (3:2, v/v) solution. Compound 1 exhibited a strong blue fluorescence. Upon addition of copper ions, the fluorescence gradually decreased and reached a plateau with the fluorescence quenching rate up to 98.73%. The detection limit for Cu2 + ions was estimated to 0.384 ppm. Fluorescent microscopy experiments demonstrated that probe 1 had potential to be used to investigate biological processes involving Cu2 + ions within living cells.

  15. Miniature probe for the delivery and monitoring of a photopolymerizable material

    Science.gov (United States)

    Schmocker, Andreas; Khoushabi, Azadeh; Schizas, Constantin; Bourban, Pierre-Etienne; Pioletti, Dominique P.; Moser, Christophe

    2015-12-01

    Photopolymerization is a common method to cure materials initially in a liquid state, such as dental implants or bone or tissue fillers. Recent advances in the development of biocompatible gel- and cement-systems open up an avenue for in situ photopolymerization. For minimally invasive surgery, such procedures require miniaturized surgical endoscopic probes to activate and control photopolymerization in situ. We present a miniaturized light probe in which a photoactive material can be (1) mixed, pressurized, and injected, (2) photopolymerized/photoactivated, and (3) monitored during the chemical reaction. The device is used to implant and cure poly(ethylene glycol) dimethacrylate-hydrogel-precursor in situ with ultraviolet A (UVA) light (365 nm) while the polymerization reaction is monitored in real time by collecting the fluorescence and Raman signals generated by the 532-nm excitation light source. Hydrogels could be delivered, photopolymerized, and monitored by the probe up to a curing depth of 4 cm. The size of the photopolymerized samples could be correlated to the fluorescent signal collected by the probe, and the reproducibility of the procedure could be demonstrated. The position of the probe tip inside a bovine caudal intervertebral disc could be estimated in vitro based on the collected fluorescence and Raman signal.

  16. Sowing Depth Effects on Vetch Yield in Maragheh Dry Lands

    Directory of Open Access Journals (Sweden)

    J Asghari Meidany

    2013-12-01

    Full Text Available Increases forage production and economic production in rainfed condition requires attention to agricultural issues such as determination of appropriate sowing depth. So in order to determine the effect of different sowing depths of vetch this experiment was conducted in Agricultural Research Station of Maragheh as strip plot based on randomized complete block design with three species of vetch V. sativa , V. dasycarpa-kouhak and V. narbonensis velox67 as main plots and three sowing depth as sub factor. Results showed that the effect of sowing depth on Vicia yield was significant at the 1% level and the maximum yield of wet hay, dry hay, straw and seed depth of belong to 8-10 cm depth and respectively are 5.364, 3.416, 4.389 and 1.081 ton per ha whereas the minimum yield of wet hay, dry hay, straw and seed depth of belong to 2-4 cm depth and respectively are 4.888, 2.318, 3.729 and 0.825. Among the three Vicia species the highest yield of wet hay, dry hay , straw and seed belongs to V. dasykarpa and respectively are 5.632, 3.532, 4.614 and 1.065 ton/ha. Soil moisture study in the field of these vetches at the time of 10 % vetch flowering showed water differences. V.dasycarpa had lower water depletion from soil. The amount of average soil water for species included: V. dasycarpa 26.31, V. sativa 23.76 and V. narbonesis 22.5.

  17. Modulation depth analysis in fast pulsations of solar radio emission

    International Nuclear Information System (INIS)

    Chernov, G.P.; Kurts, Yu.; Akademie der Wissenschaften der DDR, Berlin

    1990-01-01

    A model of millisecond pulsations due to a pulsation regime of a whistler spectrum is confirmed by the statistical analysis of the modulation depth in five type IV bursts; a modulation depth distribution ΔI/I versus the period (p) grows linearly (with the different slope) up to the maximum at the value ΔI/I ≅ 0.5-0.6. The same dependence ΔI/I(p) for spikes, observed during the same events, testifies also in favour of this model. The overlap on fast pulsations of fiber bursts and of sudden reductions are displayed in the ΔI/I(p) distribution by diffuse tails which are naturally explained by the known models of this fine structure

  18. METHOD FOR DETERMINING THE MAXIMUM ARRANGEMENT FACTOR OF FOOTWEAR PARTS

    Directory of Open Access Journals (Sweden)

    DRIŞCU Mariana

    2014-05-01

    Full Text Available By classic methodology, designing footwear is a very complex and laborious activity. That is because classic methodology requires many graphic executions using manual means, which consume a lot of the producer’s time. Moreover, the results of this classical methodology may contain many inaccuracies with the most unpleasant consequences for the footwear producer. Thus, the costumer that buys a footwear product by taking into consideration the characteristics written on the product (size, width can notice after a period that the product has flaws because of the inadequate design. In order to avoid this kind of situations, the strictest scientific criteria must be followed when one designs a footwear product. The decisive step in this way has been made some time ago, when, as a result of powerful technical development and massive implementation of electronical calculus systems and informatics, This paper presents a product software for determining all possible arrangements of a footwear product’s reference points, in order to automatically acquire the maximum arrangement factor. The user multiplies the pattern in order to find the economic arrangement for the reference points. In this purpose, the user must probe few arrangement variants, in the translation and rotate-translation system. The same process is used in establishing the arrangement factor for the two points of reference of the designed footwear product. After probing several variants of arrangement in the translation and rotation and translation systems, the maximum arrangement factors are chosen. This allows the user to estimate the material wastes.

  19. Ion energy loss at maximum stopping power in a laser-generated plasma

    International Nuclear Information System (INIS)

    Cayzac, W.

    2013-01-01

    In the frame of this thesis, a new experimental setup for the measurement of the energy loss of carbon ions at maximum stopping power in a hot laser-generated plasma has been developed and successfully tested. In this parameter range where the projectile velocity is of the same order of magnitude as the thermal velocity of the plasma free electrons, large uncertainties of up to 50% are present in the stopping-power description. To date, no experimental data are available to perform a theory benchmarking. Testing the different stopping theories is yet essential for inertial confinement fusion and in particular for the understanding of the alpha-particle heating of the thermonuclear fuel. Here, for the first time, precise measurements were carried out in a reproducible and entirely characterized beam-plasma configuration. It involved a nearly fully-stripped ion beam probing a homogeneous fully-ionized plasma. This plasma was generated by irradiating a thin carbon foil with two high-energy laser beams and features a maximum electron temperature of 200 eV. The plasma conditions were simulated with a two-dimensional radiative hydrodynamic code, while the ion-beam charge-state distribution was predicted by means of a Monte-Carlo code describing the charge-exchange processes of projectile ions in plasma. To probe at maximum stopping power, high-frequency pulsed ion bunches were decelerated to an energy of 0.5 MeV per nucleon. The ion energy loss was determined by a time-of-flight measurement using a specifically developed chemical-vapor-deposition diamond detector that was screened against any plasma radiation. A first experimental campaign was carried out using this newly developed platform, in which a precision better than 200 keV on the energy loss was reached. This allowed, via the knowledge of the plasma and of the beam parameters, to reliably test several stopping theories, either based on perturbation theory or on a nonlinear T-Matrix formalism. A preliminary

  20. Classification of permafrost active layer depth from remotely sensed and topographic evidence

    International Nuclear Information System (INIS)

    Peddle, D.R.; Franklin, S.E.

    1993-01-01

    The remote detection of permafrost (perennially frozen ground) has important implications to environmental resource development, engineering studies, natural hazard prediction, and climate change research. In this study, the authors present results from two experiments into the classification of permafrost active layer depth within the zone of discontinuous permafrost in northern Canada. A new software system based on evidential reasoning was implemented to permit the integrated classification of multisource data consisting of landcover, terrain aspect, and equivalent latitude, each of which possessed different formats, data types, or statistical properties that could not be handled by conventional classification algorithms available to this study. In the first experiment, four active layer depth classes were classified using ground based measurements of the three variables with an accuracy of 83% compared to in situ soil probe determination of permafrost active layer depth at over 500 field sites. This confirmed the environmental significance of the variables selected, and provided a baseline result to which a remote sensing classification could be compared. In the second experiment, evidence for each input variable was obtained from image processing of digital SPOT imagery and a photogrammetric digital elevation model, and used to classify active layer depth with an accuracy of 79%. These results suggest the classification of evidence from remotely sensed measures of spectral response and topography may provide suitable indicators of permafrost active layer depth

  1. Ethical issues in the use of in-depth interviews: literature review and discussion

    OpenAIRE

    Allmark, Peter; Boote, Jonathan; Chambers, E.; Clarke, Amanda; McDonnell, A.; Thompson, Andrew; Tod, Angela

    2009-01-01

    This paper reports a literature review on the topic of ethical issues in in-depth interviews. The review returned three types of article: general discussion, issues in particular studies, and studies of interview-based research ethics. Whilst many of the issues discussed in these articles are generic to research ethics, such as confidentiality, they often had particular manifestations in this type of research. For example, privacy was a significant problem as interviews sometimes probe unexpe...

  2. Using electron irradiation to probe iron-based superconductors

    Science.gov (United States)

    Cho, Kyuil; Kończykowski, M.; Teknowijoyo, S.; Tanatar, M. A.; Prozorov, R.

    2018-06-01

    High-energy electron irradiation at low temperatures is an efficient and controlled way to create vacancy–interstitial Frenkel pairs in a crystal lattice, thereby inducing nonmagnetic point-like scattering centers. In combination with London penetration depth and resistivity measurements, the electron irradiation was used as a phase-sensitive probe to study the superconducting order parameter in iron-based superconductors (FeSCs), lending strong support to sign-changing s ± pairing. Here, we review the key results of the effect of electron irradiation in FeSCs.

  3. A new fluorescent pH probe for extremely acidic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yu [School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Taishan College, Shandong University, Jinan 250100 (China); Jiang, Zheng [School of Life Science, Shandong University, Jinan 250100 (China); Taishan College, Shandong University, Jinan 250100 (China); Xiao, Yu [School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Taishan College, Shandong University, Jinan 250100 (China); Bi, Fu-Zhen [School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Miao, Jun-Ying, E-mail: miaojy@sdu.edu.cn [School of Life Science, Shandong University, Jinan 250100 (China); Zhao, Bao-Xiang, E-mail: bxzhao@sdu.edu.cn [School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China)

    2014-04-01

    A new coumarin-based fluorescent probe can detect highly acidic conditions in both solution and bacteria with high selectivity and sensitivity. Highlights: • A new fluorescence probe for very low pH was synthesized and characterized. • The probe can monitor pH in solution and bacteria. • The two-step protonation of N atoms of the probe leads to fluorescence quenching. Abstract: A novel turn-off fluorescent probe based on coumarin and imidazole moiety for extremely acidic conditions was designed and developed. The probe with pKa = 2.1 is able to respond to very low pH value (below 3.5) with high sensitivity relying on fluorescence quenching at 460 nm in fluorescence spectra or the ratios of absorbance maximum at 380 nm to that at 450 nm in UV–vis spectra. It can quantitatively detect pH value based on equilibrium equation, pH = pKa -log[(Ix - Ib)/(Ia - Ix)]. It had very short response time that was less than 1 min, good reversibility and nearly no interference from common metal ions. Moreover, using ¹H NMR analysis and theoretical calculation of molecular orbital, we verified that a two-step protonation process of two N atoms of the probe leaded to photoinduced electron transfer (PET), which was actually the mechanism of the fluorescence quenching phenomenon under strongly acidic conditions. Furthermore, the probe was also applied to imaging strong acidity in bacteria, E.coli and had good effect. This work illustrates that the new probe could be a practical and ideal pH indicator for strongly acidic conditions with good biological significance.

  4. Six Degree-of-Freedom Haptic Simulation of Probing Dental Caries Within a Narrow Oral Cavity.

    Science.gov (United States)

    Wang, Dangxiao; Zhao, Xiaohan; Shi, Youjiao; Zhang, Yuru; Hou, Jianxia; Xiao, Jing

    2016-01-01

    Haptic simulation of handling pathological tissues is a crucial component to enhance virtual surgical training systems. In this paper, we introduce a configuration-based optimization approach to simulate the exploration and diagnosis of carious tissues in dental operations. To simulate the six Degree-of-Freedom (6DoF) haptic interaction between the dental probe and the oral tissues, we introduce two interaction states, the sliding state and the penetration state, which simulate the exploration on the surface of and inside of the caries, respectively. Penetration criteria considering a contact force threshold are defined to trigger the switch between the two states. By utilizing a simplified friction model based on the optimization approach, various multi-region frictional contacts between the probe and carious tissues are simulated. To simulate the exploration within the carious tissues for diagnosing the depth of the caries, a dynamic sphere tree is used to constrain the insertion/extraction of the probe within carious tissues along a fixed direction while enabling simulation of additional contacts of the probe with neighboring oral tissues during the insertion/extraction process. Experimental results show that decays with different levels of stiffness and friction coefficients can be stably simulated. Preliminary user studies show that users could easily identify the invisible boundary between the decay and healthy tissues and correctly rank the depth of target decays within a required time limit. The proposed approach could be used for training delicate motor skill of probing target carious teeth in a narrow oral cavity, which requires collaborated control of tool posture and insertion/extraction force, while avoiding damages to adjacent healthy tissues of the tongue and gingiva.

  5. Laser-Doppler acoustic probing of granular media with in-depth property gradient and varying pore pressures

    International Nuclear Information System (INIS)

    Bodet, L.; Dhemaied, A.; Mourgues, R.; Tournat, V.; Rejiba, F.

    2012-01-01

    Non-contacting ultrasonic techniques recently proved to be efficient in the physical modeling of seismic-wave propagation at various application scales, as for instance in the context of geological analogue and seismic modeling. An innovative experimental set-up is proposed here to perform laser-Doppler acoustic probing of unconsolidated granular media with varying pore pressures. The preliminary experiments presented here provide reproducible results and exploitable data, thus validating both the proposed medium preparation and pressure gradient generation procedure.

  6. Genetic Algorithm for Opto-thermal Skin Hydration Depth Profiling Measurements

    Science.gov (United States)

    Cui, Y.; Xiao, Perry; Imhof, R. E.

    2013-09-01

    Stratum corneum is the outermost skin layer, and the water content in stratum corneum plays a key role in skin cosmetic properties as well as skin barrier functions. However, to measure the water content, especially the water concentration depth profile, within stratum corneum is very difficult. Opto-thermal emission radiometry, or OTTER, is a promising technique that can be used for such measurements. In this paper, a study on stratum corneum hydration depth profiling by using a genetic algorithm (GA) is presented. The pros and cons of a GA compared against other inverse algorithms such as neural networks, maximum entropy, conjugate gradient, and singular value decomposition will be discussed first. Then, it will be shown how to use existing knowledge to optimize a GA for analyzing the opto-thermal signals. Finally, these latest GA results on hydration depth profiling of stratum corneum under different conditions, as well as on the penetration profiles of externally applied solvents, will be shown.

  7. Predicting scour beneath subsea pipelines from existing small free span depths under steady currents

    Directory of Open Access Journals (Sweden)

    Jun Y. Lee

    2017-06-01

    Full Text Available An equation was developed to predict current-induced scour beneath subsea pipelines in areas with small span depths, S. Current equations for scour prediction are only applicable to partially buried pipelines. The existence of small span depths (i.e. S/D < 0.3 are of concern because the capacity for scour is higher at smaller span depths. Furthermore, it is impractical to perform rectification works, such as installing grout bags, under a pipeline with a small S/D. Full-scale two-dimensional computational fluid dynamics (CFD simulations were performed using the Reynolds-averaged Navier–Stokes approach and the Shear stress transport k–ω turbulence model. To predict the occurrence of scour, the computed maximum bed shear stress beneath the pipe was converted to the dimensionless Shields parameter, and compared with the critical Shields parameter based on the mean sediment grain size. The numerical setup was verified, and a good agreement was found between model-scale CFD data and experimental data. Field data were obtained to determine the mean grain size, far field current velocity and to measure the span depths along the surveyed pipe length. A trend line equation was fitted to the full-scale CFD data, whereby the maximum Shields parameter beneath the pipe can be calculated based on the undisturbed Shields parameter and S/D.

  8. Determining clinical photon beam spectra from measured depth dose with the Cimmino algorithm

    International Nuclear Information System (INIS)

    Bloch, P.; Altschuler, M.D.; Bjaerngard, B.E.; Kassaee, A.; McDonough, J.

    2000-01-01

    A method to determine the spectrum of a clinical photon beam from measured depth-dose data is described. At shallow depths, where the range of Compton-generated electrons increases rapidly with photon energy, the depth dose provides the information to discriminate the spectral contributions. To minimize the influence of contaminating electrons, small (6x6cm2 ) fields were used. The measured depth dose is represented as a linear combination of basis functions, namely the depth doses of monoenergetic photon beams derived by Monte Carlo simulations. The weights of the basis functions were obtained with the Cimmino feasibility algorithm, which examines in each iteration the discrepancy between predicted and measured depth dose. For 6 and 15 MV photon beams of a clinical accelerator, the depth dose obtained from the derived spectral weights was within about 1% of the measured depth dose at all depths. Because the problem is ill conditioned, solutions for the spectrum can fluctuate with energy. Physically realistic smooth spectra for these photon beams appeared when a small margin (about ±1%) was attributed to the measured depth dose. The maximum energy of both derived spectra agreed with the measured energy of the electrons striking the target to within 1 MeV. The use of a feasibility method on minimally relaxed constraints provides realistic spectra quickly and interactively. (author)

  9. Mechanical solution of the maximum point of dynamic abutment pressure under deep long-wall working face

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, F.; Ma, Q. [Shandong University of Science and Technology, Tai' an (China). College of Resource and Environmental Engineering

    2002-06-01

    The paper studies the dynamic relationship between abutment pressure and overburden collapse precess with advancing of working face. The result shows that the abutment pressure reaches its maximum value when the working face dimension is 1.27 times of the mining depth. This result confirms the statistical result from the strata movement surveys that overburden reaches its full movement stage when extracting dimension reaches 1.2 1.4 times of the mining depth. 12 refs., 2 figs.

  10. Synopsis of moisture monitoring by neutron probe in the unsaturated zone at Area G

    International Nuclear Information System (INIS)

    Vold, E.

    1997-01-01

    Moisture profiles from neutron probe data provide valuable information in site characterization and to supplement ground water monitoring efforts. The neutron probe precision error (reproducibility) is found to be about 0.2 vol% under in situ field conditions where the slope in moisture content with depth is varying slowly. This error is about 2 times larger near moisture spikes (e.g., at the vapor phase notch), due to the sensitivity of the probe response to vertical position errors on the order of 0.5 inches. Calibrations were performed to correct the downhole probe response to the volumetric moisture content determined on core samples. Calibration is sensitive to borehole diameter and casing type, requiring 3 separate calibration relations for the boreholes surveyed here. Power law fits were used for calibration in this study to assure moisture content results greater than zero. Findings in the boreholes reported here confirm the broad features seen previously in moisture profiles at Area G, a near-surface region with large moisture variability, a very dry region at greater depths, and a moisture spike at the vapor phase notch (VPN). This feature is located near the interface between the vitrified and vitrified stratigraphic units and near the base of the mesa. This report describes the in-field calibration methods used for the neutron moisture probe measurements and summarizes preliminary results of the monitoring program in the in-situ monitoring network at Area G. Reported results include three main areas: calibration studies, profiles from each of the vertical boreholes at Area G, and time-dependent variations in a select subset of boreholes. Results are reported here for the vertical borehole network. Results from the horizontal borehole network will be described when available

  11. High Resolution Depth-Resolved Imaging From Multi-Focal Images for Medical Ultrasound

    DEFF Research Database (Denmark)

    Diamantis, Konstantinos; Dalgarno, Paul A.; Greenaway, Alan H.

    2015-01-01

    An ultrasound imaging technique providing subdiffraction limit axial resolution for point sources is proposed. It is based on simultaneously acquired multi-focal images of the same object, and on the image metric of sharpness. The sharpness is extracted by image data and presents higher values...... calibration curves combined with the use of a maximum-likelihood algorithm is then able to estimate, with high precision, the depth location of any emitter fron each single image. Estimated values are compared with the ground truth demonstrating that an accuracy of 28.6 µm (0.13λ) is achieved for a 4 mm depth...

  12. Numerical simulation of permafrost depth during a future glaciation, Campine area, Northern Belgium

    International Nuclear Information System (INIS)

    Govaerts, Joan; Weetjens, Eef; Beerten, Koen

    2012-01-01

    Document available in extended abstract form only. Given the long time frames involved and their potential detrimental effects, climate changes are considered in the safety assessment of long-term geological disposal of radioactive waste. One such effect that climate changes may govern is the re-appearance of permafrost in north-western Europe. This condition already existed during previous glaciations (e.g., Weichselian glacial, 115-11 ka BP), and may have several consequences for the hydrosphere, geosphere, biosphere and repository. Here, we present calculations of permafrost depth based on the climatic scenario with the Weichselian (last glacial) as an analog to estimate the permafrost depth during a future glaciation. Whereas the lateral extent of permafrost can be deduced from surface features, not much is known about the maximum depth of permafrost during a cold stage in the Campine region. Realistic values of the latent heat of melting of pure water, and thermal conductivity of dry or frozen and unfrozen saturated sand and clay are used as input parameters. In addition, detailed and refined climatic scenarios for the last glacial are used to improve the quality of boundary conditions, together with a more advanced description of freezing/thawing processes. To describe heat transport in the subsoil of the Mol site, the one-dimensional enthalpy conservation equation is used with heat transport only occurring by conduction. In the first calculation case, the temperature at the top of the soil layer is set equal to the air temperatures of a realistic glacial cycle (Weichselian glaciation). In a second calculation case, the insulating effects of the surface cover are considered, and the air temperatures are converted into surface temperatures by making use of the 'n-factor concept', which yields an empirical relationship between the mean annual surface temperature, T s , and the mean annual air temperature, T a . In Figure 1 the permafrost pro-gradation front

  13. Calibration of a neutron probe for determining the humidity in deep alluvial soils

    International Nuclear Information System (INIS)

    Ferrer, A.; Rivero, H.; Lopez, F.; Cantillo, O.

    1993-01-01

    Preliminary data for the calibration of a neutron probe in deep alluvial soils for determining the humidity are reported. Comparisons of Neutron flow behaviour with the depth of the land are established. A characteristic curve of amount of detected neutrons according to the humidity percentage (from 50 to 100 % of the field humidity) is obtained

  14. Pump-probe studies of travelling coherent longitudinal acoustic phonon oscillations in GaAs

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Y.; Qi, J.; Tolk, Norman [Department of Physics and Astronomy, Vanderbilt University, Nashville, TN, 37235 (United States); Miller, J. [Naval air Warfare Center Weapons Division, China Lake, CA 93555 (United States); Cho, Y.J.; Liu, X.; Furdyna, J.K. [Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States); Shahbazyan, T.V. [Department of Physics, Jackson State University, MS 39217 (United States)

    2008-07-01

    We report comprehensive studies of long-lived oscillations in femtosecond optical pump-probe measurements on GaAs based systems. The oscillations arise from a photo-generated coherent longitudinal acoustic phonon wave at the sample surface, which subsequently travels from the surface into the GaAs substrate, thus providing information on the optical properties of the material as a function of time/depth. Wavelength-dependent studies of the oscillations near the bandgap of GaAs indicate strong correlations to the optical properties of GaAs. We also use the coherent longitudinal acoustic phonon waves to probe a thin buried Ga{sub 0.1}In{sub 0.9}As layers non-invasively. The observed phonon oscillations experience a reduction in amplitude and a phase change at wavelengths near the bandgap of the GaAs, when it passes through the thin Ga{sub x}In{sub 1-x}As layer. The layer depth and thicknesses can be extracted from the oscillation responses. A model has been developed that satisfactorily characterizes the experimental results. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  15. Efficiency of subsoiling depth according to the slope of the land

    Directory of Open Access Journals (Sweden)

    Daniel Pena Pereira

    2012-12-01

    Full Text Available The effectiveness of subsoiling by measuring the depths achieved in different classes of slope of a forest plantation was evaluated. This operation was made with a fertilizer trawling subsoiler with a single smooth parabolic rod depending on seven groups of slope and the maximum lateral inclination of the tractor to perform the subsoiling. It was determined the number and breadth of slope classes by Sturges formula. Data were assessed by regression analysis for data with repetition at 5% significance level. The proposed regression model was adequate to describe the values given that it presented significant result for the F test. For the adjustment of the regression equation, the coefficient of determination was 78.95%, representing the the depth values that are explained by the slope. Thus, it can be said that the depth of subsoiling decreases as the steepness of the ground increases and is a limiter for the quality of the mechanized soil preparation. The results demonstrate that slopes up to 40% allowed the operation of subsoiling to reach the minimum depth of 0.50 m for forest cultivation.

  16. Use of gamma probe in 131I thyroid uptake studies

    International Nuclear Information System (INIS)

    Sarmento, Andrea Gondim Leitao

    2002-11-01

    Evaluation of thyroid uptake by administration of radioactive iodine is a well-defined procedure to assess patient thyroid function. In general, nuclear medicine institutions use gamma cameras coupled to pinhole collimators to perform uptake studies. With the growing use of intraoperative gamma probes in the radioguided surgical techniques, several institutions are purchasing this new and portable equipment, which can technically be also employed to assess patient's thyroid function, permitting further other applications of gamma cameras. The aim of the study was to compare thyroid uptake trails carried out with both gamma camera and intraoperative gamma probe, in order to evaluate the possible use of gamma probe for this purpose. At first a preliminary study of feasibility was carried out using a neck phantom to verify equipment efficiency with known activities of 131 I. Henceforth, work data from 12 patients undergone studies of thyroid uptakes were evaluated, 24 hours after oral administration of 370 kBq of 131 I. The maximum difference observed between the values obtained with both equipment was 60%, which demonstrated the feasibility of the proposed protocol and made clear that gamma probe can be useful for thyroid uptake studies. (author)

  17. Knee Kinetics during Squats of Varying Loads and Depths in Recreationally Trained Females.

    Science.gov (United States)

    Flores, Victoria; Becker, James; Burkhardt, Eric; Cotter, Joshua

    2018-03-06

    The back squat exercise is typically practiced with varying squat depths and barbell loads. However, depth has been inconsistently defined, resulting in unclear safety precautions when squatting with loads. Additionally, females exhibit anatomical and kinematic differences to males which may predispose them to knee joint injuries. The purpose of this study was to characterize peak knee extensor moments (pKEMs) at three commonly practiced squat depths of above parallel, parallel, and full depth, and with three loads of 0% (unloaded), 50%, and 85% depth-specific one repetition maximum (1RM) in recreationally active females. Nineteen females (age, 25.1 ± 5.8 years; body mass, 62.5 ± 10.2 kg; height, 1.6 ± 0.10 m; mean ± SD) performed squats of randomized depth and load. Inverse dynamics were used to obtain pKEMs from three-dimensional knee kinematics. Depth and load had significant interaction effects on pKEMs (p = 0.014). Significantly greater pKEMs were observed at full depth compared to parallel depth with 50% 1RM load (p = 0.001, d = 0.615), and 85% 1RM load (p = 0.010, d = 0.714). Greater pKEMs were also observed at full depth compared to above parallel depth with 50% 1RM load (p = 0.003, d = 0.504). Results indicate effect of load on female pKEMs do not follow a progressively increasing pattern with either increasing depth or load. Therefore, when high knee loading is a concern, individuals are must carefully consider both the depth of squat being performed and the relative load they are using.

  18. Use of Neutron Probe to Quantify the Soil Moisture Flux in Layers of Cultivated Soil by Chickpea

    International Nuclear Information System (INIS)

    El- Gendy, R.W.

    2008-01-01

    This work aims to use the neutron moisture meter and the soil moisture retention curve to quantify the soil moisture flux in the soil profile of Nubarria soil in Egypt at 15, 30, 45, and 60-cm depths during the growth season of Chickpea. This method depends on the use of in situ θ measurements via neutron moisture meter and soil matric suction using model of the soil moisture retention curve at different soil depths, which can be determined in situ. Total hydraulic potential values at the different soil depths were calculated as a function (θ) using the derivative model. The gradient of hydraulic potential at any soil depth can be obtained by detecting of the hydraulic potential within the soil profile. The soil water fluxes at the different soil depths were calculated using In situ measured unsaturated hydraulic conductivity and the gradient of hydraulic potential, which correlated with soil moisture contents as measured by neutron probe. Values of hydraulic potentials after and before irrigation indicate that the direction of soil moisture movement was downward after irrigation and was different before next irrigation. Collecting active roots for water absorption of chickpea were defined from direction of soil water movement from up and down to a certain soil depth was 19 cm depth from the soil surface. Active rooting depth was 53 cm depth, which separates between evapotranspiration and gravity effects The soil water fluxes after and before the next irrigation of chickpea were 1.2453, 0.8613, 0.8197 and 0.6588 cm/hr and 0.0037, - 0.0270,- 0.1341, and 0.2545 cm/hr at 15, 30, 45 and 60 cm depths, respectively. The negative values at 30 and 45 cm depth before the next irrigation indicates there were up ward movement for soil water flux, where finding collecting active roots for water absorption of chickpea at 19 cm depth. Direction of soil water movement, soil water flux, collecting active roots for water absorption and active rooting depth can be determined using

  19. Near-field examination of perovskite-based superlenses and superlens-enhanced probe-object coupling.

    Science.gov (United States)

    Kehr, S C; Liu, Y M; Martin, L W; Yu, P; Gajek, M; Yang, S-Y; Yang, C-H; Wenzel, M T; Jacob, R; von Ribbeck, H-G; Helm, M; Zhang, X; Eng, L M; Ramesh, R

    2011-01-01

    A planar slab of negative-index material works as a superlens with sub-diffraction-limited resolution, as propagating waves are focused and, moreover, evanescent waves are reconstructed in the image plane. Here we demonstrate a superlens for electric evanescent fields with low losses using perovskites in the mid-infrared regime. The combination of near-field microscopy with a tunable free-electron laser allows us to address precisely the polariton modes, which are critical for super-resolution imaging. We spectrally study the lateral and vertical distributions of evanescent waves around the image plane of such a lens, and achieve imaging resolution of λ/14 at the superlensing wavelength. Interestingly, at certain distances between the probe and sample surface, we observe a maximum of these evanescent fields. Comparisons with numerical simulations indicate that this maximum originates from an enhanced coupling between probe and object, which might be applicable for multifunctional circuits, infrared spectroscopy and thermal sensors.

  20. Near-field examination of perovskite-based superlenses and superlens-enhanced probe-object coupling

    Science.gov (United States)

    Kehr, S.C.; Liu, Y.M.; Martin, L.W.; Yu, P.; Gajek, M.; Yang, S.-Y.; Yang, C.-H.; Wenzel, M.T.; Jacob, R.; von Ribbeck, H.-G.; Helm, M.; Zhang, X.; Eng, L.M.; Ramesh, R.

    2011-01-01

    A planar slab of negative-index material works as a superlens with sub-diffraction-limited resolution, as propagating waves are focused and, moreover, evanescent waves are reconstructed in the image plane. Here we demonstrate a superlens for electric evanescent fields with low losses using perovskites in the mid-infrared regime. The combination of near-field microscopy with a tunable free-electron laser allows us to address precisely the polariton modes, which are critical for super-resolution imaging. We spectrally study the lateral and vertical distributions of evanescent waves around the image plane of such a lens, and achieve imaging resolution of λ/14 at the superlensing wavelength. Interestingly, at certain distances between the probe and sample surface, we observe a maximum of these evanescent fields. Comparisons with numerical simulations indicate that this maximum originates from an enhanced coupling between probe and object, which might be applicable for multifunctional circuits, infrared spectroscopy and thermal sensors. PMID:21427720

  1. Productivity response of calcareous nannoplankton to Eocene Thermal Maximum 2 (ETM2

    Directory of Open Access Journals (Sweden)

    M. Dedert

    2012-05-01

    Full Text Available The Early Eocene Thermal Maximum 2 (ETM2 at ~53.7 Ma is one of multiple hyperthermal events that followed the Paleocene-Eocene Thermal Maximum (PETM, ~56 Ma. The negative carbon excursion and deep ocean carbonate dissolution which occurred during the event imply that a substantial amount (103 Gt of carbon (C was added to the ocean-atmosphere system, consequently increasing atmospheric CO2(pCO2. This makes the event relevant to the current scenario of anthropogenic CO2 additions and global change. Resulting changes in ocean stratification and pH, as well as changes in exogenic cycles which supply nutrients to the ocean, may have affected the productivity of marine phytoplankton, especially calcifying phytoplankton. Changes in productivity, in turn, may affect the rate of sequestration of excess CO2 in the deep ocean and sediments. In order to reconstruct the productivity response by calcareous nannoplankton to ETM2 in the South Atlantic (Site 1265 and North Pacific (Site 1209, we employ the coccolith Sr/Ca productivity proxy with analysis of well-preserved picked monogeneric populations by ion probe supplemented by analysis of various size fractions of nannofossil sediments by ICP-AES. The former technique of measuring Sr/Ca in selected nannofossil populations using the ion probe circumvents possible contamination with secondary calcite. Avoiding such contamination is important for an accurate interpretation of the nannoplankton productivity record, since diagenetic processes can bias the productivity signal, as we demonstrate for Sr/Ca measurements in the fine (<20 μm and other size fractions obtained from bulk sediments from Site 1265. At this site, the paleoproductivity signal as reconstructed from the Sr/Ca appears to be governed by cyclic changes, possibly orbital forcing, resulting in a 20–30% variability in Sr/Ca in dominant genera as obtained by ion probe. The ~13 to 21

  2. Comparison in performance of sediment microbial fuel cells according to depth of embedded anode.

    Science.gov (United States)

    An, Junyeong; Kim, Bongkyu; Nam, Jonghyeon; Ng, How Yong; Chang, In Seop

    2013-01-01

    Five rigid graphite plates were embedded in evenly divided sections of sediment, ranging from 2 cm (A1) to 10 cm (A5) below the top sediment layer. The maximum power and current of the MFCs increased in depth order; however, despite the increase in the internal resistance, the power and current density of the A5 MFC were 2.2 and 3.5 times higher, respectively, than those of the A1 MFC. In addition, the anode open circuit potentials (OCPs) of the sediment microbial fuel cells (SMFCs) became more negative with sediment depth. Based on these results, it could be then concluded that as the anode-embedding depth increases, that the anode environment is thermodynamically and kinetically favorable to anodophiles or electrophiles. Therefore, the anode-embedding depth should be considered an important parameter that determines the performance of SMFCs, and we posit that the anode potential could be one indicator for selecting the anode-embedding depth. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. An MR/MRI compatible core holder with the RF probe immersed in the confining fluid

    Science.gov (United States)

    Shakerian, M.; Balcom, B. J.

    2018-01-01

    An open frame RF probe for high pressure and high temperature MR/MRI measurements was designed, fabricated, and tested. The open frame RF probe was installed inside an MR/MRI compatible metallic core holder, withstanding a maximum pressure and temperature of 5000 psi and 80 °C. The open frame RF probe was tunable for both 1H and 19F resonance frequencies with a 0.2 T static magnetic field. The open frame structure was based on simple pillars of PEEK polymer upon which the RF probe was wound. The RF probe was immersed in the high pressure confining fluid during operation. The open frame structure simplified fabrication of the RF probe and significantly reduced the amount of polymeric materials in the core holder. This minimized the MR background signal detected. Phase encoding MRI methods were employed to map the spin density of a sulfur hexafluoride gas saturating a Berea core plug in the core holder. The SF6 was imaged as a high pressure gas and as a supercritical fluid.

  4. Influence of probe motion on laser probe temperature in circulating blood.

    Science.gov (United States)

    Hehrlein, C; Splinter, R; Littmann, L; Tuntelder, J R; Tatsis, G P; Svenson, R H

    1991-01-01

    The purpose of this study was to evaluate the effect of probe motion on laser probe temperature in various blood flow conditions. Laser probe temperatures were measured in an in vitro blood circulation model consisting of 3.2 nm-diameter plastic tubes. A 2.0 mm-diameter metal probe attached to a 300 microns optical quartz fiber was coupled to an argon laser. Continuous wave 4 watts and 8 watts of laser power were delivered to the fiber tip corresponding to a 6.7 +/- 0.5 and 13.2 +/- 0.7 watts power setting at the laser generator. The laser probe was either moved with constant velocity or kept stationary. A thermocouple inserted in the lateral portion of the probe was used to record probe temperatures. Probe temperature changes were found with the variation of laser power, probe velocity, blood flow, and duration of laser exposure. Probe motion significantly reduced probe temperatures. After 10 seconds of 4 watts laser power the probe temperature in stagnant blood decreased from 303 +/- 18 degrees C to 113 +/- 17 degrees C (63%) by moving the probe with a velocity of 5 cm/sec. Blood flow rates of 170 ml/min further decreased the probe temperature from 113 +/- 17 degrees C to 50 +/- 8 degrees C (56%). At 8 watts of laser power a probe temperature reduction from 591 +/- 25 degrees C to 534 +/- 36 degrees C (10%) due to 5 cm/sec probe velocity was noted. Probe temperatures were reduced to 130 +/- 30 degrees C (78%) under the combined influence of 5 cm/sec probe velocity and 170 ml/min blood flow.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. In-line optical fiber metallic mirror reflector for monolithic common path optical coherence tomography probes.

    Science.gov (United States)

    Singh, Kanwarpal; Reddy, Rohith; Sharma, Gargi; Verma, Yogesh; Gardecki, Joseph A; Tearney, Guillermo

    2018-03-01

    Endoscopic optical coherence tomography probes suffer from various artifacts due to dispersion imbalance and polarization mismatch between reference and sample arm light. Such artifacts can be minimized using a common path approach. In this work, we demonstrate a miniaturized common path probe for optical coherence tomography using an inline fiber mirror. A common path optical fiber probe suitable for performing high-resolution endoscopic optical coherence tomography imaging was developed. To achieve common path functionality, an inline fiber mirror was fabricated using a thin gold layer. A commercially available swept source engine was used to test the designed probe in a cadaver human coronary artery ex vivo. We achieved a sensitivity of 104 dB for this probe using a swept source optical coherence tomography system. To test the probe, images of a cadaver human coronary artery were obtained, demonstrating the quality that is comparable to those obtained by OCT systems with separate reference arms. Additionally, we demonstrate recovery of ranging depth by use of a Michelson interferometer in the detection path. We developed a miniaturized monolithic inline fiber mirror-based common path probe for optical coherence tomography. Owing to its simplicity, our design will be helpful in endoscopic applications that require high-resolution probes in a compact form factor while reducing system complexity. Lasers Surg. Med. 50:230-235, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  6. The depth distribution of bubbles and fracture in He+ and D+ irradiated copper

    International Nuclear Information System (INIS)

    Johnson, P.B.; Mazey, D.J.

    1982-01-01

    Transmission electron microscopy is used to investigate the spatial arrangement and distribution with depth of gas bubbles produced in Cu by irradiation at 320 K to a level approx. equal to 4 x 10 21 30 keV He + m -2 . At the depth of maximum bubble size the bubbles are random and large (up to approx. equal to 10 nm across). At both shallower and greater depths the gas bubbles are smaller (approx. equal to 2 nm diam), much more uniform in size and ordered on an fcc superlattice with a lattice constant of a 1 approx. equal to 7.7 nm which (in contrast to the average bubble size) is independent of depth. It is suggested that blistering results from fracture, at a depth near the mean projected range, between large randomly-ordered bubbles which have evolved from smaller bubbles of uniform size arranged on a superlattice. For the particular case of D + irradiation of Cu at 120 K evidence is found to suggest that the fracture mechanisms involved in blistering and flaking are quite different. (orig.)

  7. Statistically sound evaluation of trace element depth profiles by ion beam analysis

    International Nuclear Information System (INIS)

    Schmid, K.; Toussaint, U. von

    2012-01-01

    This paper presents the underlying physics and statistical models that are used in the newly developed program NRADC for fully automated deconvolution of trace level impurity depth profiles from ion beam data. The program applies Bayesian statistics to find the most probable depth profile given ion beam data measured at different energies and angles for a single sample. Limiting the analysis to % level amounts of material allows one to linearize the forward calculation of ion beam data which greatly improves the computation speed. This allows for the first time to apply the maximum likelihood approach to both the fitting of the experimental data and the determination of confidence intervals of the depth profiles for real world applications. The different steps during the automated deconvolution will be exemplified by applying the program to artificial and real experimental data.

  8. Maximum likelihood estimation of the position of a radiating source in a waveguide

    International Nuclear Information System (INIS)

    Hinich, M.J.

    1979-01-01

    An array of sensors is receiving radiation from a source of interest. The source and the array are in a one- or two-dimensional waveguide. The maximum-likelihood estimators of the coordinates of the source are analyzed under the assumptions that the noise field is Gaussian. The Cramer-Rao lower bound is of the order of the number of modes which define the source excitation function. The results show that the accuracy of the maximum likelihood estimator of source depth using a vertical array in a infinite horizontal waveguide (such as the ocean) is limited by the number of modes detected by the array regardless of the array size

  9. Integration time for the perception of depth from motion parallax.

    Science.gov (United States)

    Nawrot, Mark; Stroyan, Keith

    2012-04-15

    The perception of depth from relative motion is believed to be a slow process that "builds-up" over a period of observation. However, in the case of motion parallax, the potential accuracy of the depth estimate suffers as the observer translates during the viewing period. Our recent quantitative model for the perception of depth from motion parallax proposes that relative object depth (d) can be determined from retinal image motion (dθ/dt), pursuit eye movement (dα/dt), and fixation distance (f) by the formula: d/f≈dθ/dα. Given the model's dynamics, it is important to know the integration time required by the visual system to recover dα and dθ, and then estimate d. Knowing the minimum integration time reveals the incumbent error in this process. A depth-phase discrimination task was used to determine the time necessary to perceive depth-sign from motion parallax. Observers remained stationary and viewed a briefly translating random-dot motion parallax stimulus. Stimulus duration varied between trials. Fixation on the translating stimulus was monitored and enforced with an eye-tracker. The study found that relative depth discrimination can be performed with presentations as brief as 16.6 ms, with only two stimulus frames providing both retinal image motion and the stimulus window motion for pursuit (mean range=16.6-33.2 ms). This was found for conditions in which, prior to stimulus presentation, the eye was engaged in ongoing pursuit or the eye was stationary. A large high-contrast masking stimulus disrupted depth-discrimination for stimulus presentations less than 70-75 ms in both pursuit and stationary conditions. This interval might be linked to ocular-following response eye-movement latencies. We conclude that neural mechanisms serving depth from motion parallax generate a depth estimate much more quickly than previously believed. We propose that additional sluggishness might be due to the visual system's attempt to determine the maximum dθ/dα ratio

  10. Observation of quantized vortices by cryocooler-based scanning Hall probe microscope

    Energy Technology Data Exchange (ETDEWEB)

    Tokunaga, Y.; Konishi, Y.; Tokunaga, M.; Tamegai, T

    2004-10-01

    We have developed a scanning Hall probe microscope (SHPM) system utilizing closed-cycle cryocooler. The Hall probe used in this system is fabricated from a GaAs/GaAlAs two-dimensional electron gas. A stepping-motor-driven XYZ translator is used with a resolution better than 0.1 {mu}m and maximum scan range of 20 x 20 mm{sup 2}. The spatial resolution of the system is about 5 {mu}m and magnetic resolution is about 100 mG. By using this system, we have successfully resolved the quantized vortices on the cleaved surface of Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+y} single crystal.

  11. Spatiotemporal variability of snow depth across the Eurasian continent from 1966 to 2012

    Science.gov (United States)

    Zhong, Xinyue; Zhang, Tingjun; Kang, Shichang; Wang, Kang; Zheng, Lei; Hu, Yuantao; Wang, Huijuan

    2018-01-01

    Snow depth is one of the key physical parameters for understanding land surface energy balance, soil thermal regime, water cycle, and assessing water resources from local community to regional industrial water supply. Previous studies by using in situ data are mostly site specific; data from satellite remote sensing may cover a large area or global scale, but uncertainties remain large. The primary objective of this study is to investigate spatial variability and temporal change in snow depth across the Eurasian continent. Data used include long-term (1966-2012) ground-based measurements from 1814 stations. Spatially, long-term (1971-2000) mean annual snow depths of >20 cm were recorded in northeastern European Russia, the Yenisei River basin, Kamchatka Peninsula, and Sakhalin. Annual mean and maximum snow depth increased by 0.2 and 0.6 cm decade-1 from 1966 through 2012. Seasonally, monthly mean snow depth decreased in autumn and increased in winter and spring over the study period. Regionally, snow depth significantly increased in areas north of 50° N. Compared with air temperature, snowfall had greater influence on snow depth during November through March across the former Soviet Union. This study provides a baseline for snow depth climatology and changes across the Eurasian continent, which would significantly help to better understanding climate system and climate changes on regional, hemispheric, or even global scales.

  12. On-line depth measurement for laser-drilled holes based on the intensity of plasma emission

    Science.gov (United States)

    Ho, Chao-Ching; Chiu, Chih-Mu; Chang, Yuan-Jen; Hsu, Jin-Chen; Kuo, Chia-Lung

    2014-09-01

    The direct time-resolved depth measurement of blind holes is extremely difficult due to the short time interval and the limited space inside the hole. This work presents a method that involves on-line plasma emission acquisition and analysis to obtain correlations between the machining processes and the optical signal output. Given that the depths of laser-machined holes can be estimated on-line using a coaxial photodiode, this was employed in our inspection system. Our experiments were conducted in air under normal atmospheric conditions without gas assist. The intensity of radiation emitted from the vaporized material was found to correlate with the depth of the hole. The results indicate that the estimated depths of the laser-drilled holes were inversely proportional to the maximum plasma light emission measured for a given laser pulse number.

  13. Atom probe, AFM and STM study on vacuum fired stainless steel

    International Nuclear Information System (INIS)

    Stupnik, A.; Frank, P.; Leisch, M.

    2008-01-01

    Full text: Stainless steel is one of the most commonly used structural materials for vacuum equipment. An efficient method to reduce the outgassing rate from stainless steel is a high temperature bakeout in vacuum (vacuum firing). This procedure reduces significantly the amount of dissolved hydrogen in the bulk. For the outgassing process the recombination rate of hydrogen atoms to the molecules plays the determining role and recombination is strongly related to the surface structure and composition. To get more detailed information about the surface morphology and composition AFM, STM and atom probe studies were carried out. Experiments on AISI 304L stainless steel samples show that the surface reconstructs completely during vacuum firing and large atomically flat terraces bounded by bunched steps and facets are formed. The large flat terraces can be assigned to (111) planes. The bunched steps and facets are corresponding in orientation almost to (110) planes and (100) planes. Surface inspection after vacuum firing by Auger electron spectroscopy (AES) gives reason for a composition change indicated by a reduction of the chromium signal in relation to the iron and nickel signal. Since the information depth of AES covers several atomic layers not only the top atomic layer of the sample surface is probed. For this reason 3D atom probe was used as well suited tool to investigate the segregation behavior of this alloy with the goal to examine the change in local chemical composition due to the high temperature treatment. As a result of vacuum firing the atom probe experiments show a significant enrichment of nickel at the top surface layer. In the second atomic layer chromium enrichment is detected. After vacuum firing the average composition below the second atomic layer shows certain chromium depletion up to 2 nm in depth. The observed changes in surface chemistry influence recombination and desorption probability from the surface and may contribute to the present

  14. Evaluation of Depth of Field for depth perception in DVR

    KAUST Repository

    Grosset, A.V.Pascal; Schott, Mathias; Bonneau, Georges-Pierre; Hansen, Charles D.

    2013-01-01

    In this paper we present a user study on the use of Depth of Field for depth perception in Direct Volume Rendering. Direct Volume Rendering with Phong shading and perspective projection is used as the baseline. Depth of Field is then added to see its impact on the correct perception of ordinal depth. Accuracy and response time are used as the metrics to evaluate the usefulness of Depth of Field. The onsite user study has two parts: static and dynamic. Eye tracking is used to monitor the gaze of the subjects. From our results we see that though Depth of Field does not act as a proper depth cue in all conditions, it can be used to reinforce the perception of which feature is in front of the other. The best results (high accuracy & fast response time) for correct perception of ordinal depth occurs when the front feature (out of the two features users were to choose from) is in focus and perspective projection is used. © 2013 IEEE.

  15. Evaluation of Depth of Field for depth perception in DVR

    KAUST Repository

    Grosset, A.V.Pascal

    2013-02-01

    In this paper we present a user study on the use of Depth of Field for depth perception in Direct Volume Rendering. Direct Volume Rendering with Phong shading and perspective projection is used as the baseline. Depth of Field is then added to see its impact on the correct perception of ordinal depth. Accuracy and response time are used as the metrics to evaluate the usefulness of Depth of Field. The onsite user study has two parts: static and dynamic. Eye tracking is used to monitor the gaze of the subjects. From our results we see that though Depth of Field does not act as a proper depth cue in all conditions, it can be used to reinforce the perception of which feature is in front of the other. The best results (high accuracy & fast response time) for correct perception of ordinal depth occurs when the front feature (out of the two features users were to choose from) is in focus and perspective projection is used. © 2013 IEEE.

  16. How Choice of Depth Horizon Influences the Estimated Spatial Patterns and Global Magnitude of Ocean Carbon Export Flux

    Science.gov (United States)

    Palevsky, Hilary I.; Doney, Scott C.

    2018-05-01

    Estimated rates and efficiency of ocean carbon export flux are sensitive to differences in the depth horizons used to define export, which often vary across methodological approaches. We evaluate sinking particulate organic carbon (POC) flux rates and efficiency (e-ratios) in a global earth system model, using a range of commonly used depth horizons: the seasonal mixed layer depth, the particle compensation depth, the base of the euphotic zone, a fixed depth horizon of 100 m, and the maximum annual mixed layer depth. Within this single dynamically consistent model framework, global POC flux rates vary by 30% and global e-ratios by 21% across different depth horizon choices. Zonal variability in POC flux and e-ratio also depends on the export depth horizon due to pronounced influence of deep winter mixing in subpolar regions. Efforts to reconcile conflicting estimates of export need to account for these systematic discrepancies created by differing depth horizon choices.

  17. A new method for intraoperative localization of epilepsy focus by means of a gamma probe; Um novo metodo para a localizacao intraoperatoria de foco de epilepsia mediante utilizacao de gamaprobe

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro Filho, Omar, E-mail: dromarcarneiro@gmail.com [Centro Brasileiro de Medicina Nuclear e Imagem Molecular (CEBRAMEN), Goiania, GO (Brazil); Instituto de Medicina Nuclear, Goiania, GO (Brazil); Vilela Filho, Osvaldo [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Hospital das Clinicas. Servico de Neurocirurgia; Ragazzo, Paulo Cesar [Instituto de Neurologia de Goiania, GO (Brazil). Servico de Eplepsia e Neurofisiologia; Fonseca, Lea Mirian Barbosa da [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Radiologia

    2014-01-15

    Objective: to evaluate the utility of a new multimodal image-guided intervention technique to detect epileptogenic areas with a gamma probe as compared with intraoperative electrocorticography. Materials and methods: two symptomatic patients with refractory epilepsy underwent magnetic resonance imaging, videoelectroencephalography, brain SPECT scan, neuropsychological evaluation and were submitted to gamma probe-assisted surgery. Results: in patient 1, maximum radioactive count was initially observed on the temporal gyrus at about 3.5 cm posteriorly to the tip of the left temporal lobe. After corticotomy, the gamma probe indicated maximum count at the head of the hippocampus, in agreement with the findings of intraoperative electrocorticography. In patient 2, maximum count was observed in the occipital region at the transition between the temporal and parietal lobes (right hemisphere). During the surgery, the area of epileptogenic activity mapped at electrocorticography was also delimited, demarcated, and compared with the gamma probe findings. After lesionectomy, new radioactive counts were performed both in the patients and on the surgical specimens (ex-vivo). Conclusion: the comparison between intraoperative electrocorticography and gamma probe-assisted surgery showed similarity of both methods. The advantages of gamma probe include: noninvasiveness, low cost and capacity to demonstrate decrease in the radioactive activity at the site of excision after lesionectomy. (author)

  18. Adaptation of spectral distribution of synchrotron radiation to X-ray depth lithography

    International Nuclear Information System (INIS)

    Maid, B.; Ehrfeld, W.; Hormes, J.; Mohr, J.; Muenchmeyer, D.

    1989-05-01

    Plastic microstructures with extremly high aspect ratios can be fabricated by X-ray depth lithography with synchrotron radiation. In order to minimize the expenditure in terms of irradiation the spectrum of the synchrotron radiation source has to be adapted to the irradiation task. It is characterized by the height of the microstructure and the maximum admissible dose ratio permitting the resist to develop in the depth without destruction of the surface as a result of radiation damage. Expenditure in terms of irradiation is minimum if an ideal sharp cutoff filter, profiting from the maximum permissible dose ratio, filters out the long-waved portion of the spectrum without attenuating the intensity of the short-waved portion of the spectrum. By the example of a typical resist-developer system the location of the filter edge was determined at different structural heights for the Bonn synchrotron and the ELSA electron stretching facility (Bonn). To be capable of building the ideal sharp cutoff filter, the thickness of an absorber was adapted for different materials in such a way that the maximum permissible dose ratio was obtained. If a thin reflector foil is used which is hit by glazing radiation, the expenditure in terms of irradiation can be reduced because of the steeper filter characteristic of resists with small maximum dose ratios. The short-waved transmitted beam is used for irradiation, with the filter edge set by the angle between the foil and the beam. The technical feasibility of a reflection filter was demonstrated on the model of a reflector foil consisting of 30 nm titanium on 7.5 μm polyimide substrate by transmission measurements performed at different angles. (orig./HP) [de

  19. Experimental study on depth of paraffin wax over floating absorber plate in built-in storage solar water heater

    Directory of Open Access Journals (Sweden)

    R Sivakumar

    2015-11-01

    Full Text Available The aim of this article is to study the effect of depth of phase change material over the absorber surface of an integrated collector-storage type flat plate solar water heater. Flat plate solar water heaters are extensively used all over the world to utilize the natural source of solar energy. In order to utilize the solar energy during off-sunshine hours, it is inevitable to store and retain solar thermal energy as long as possible. Here, phase change material is not used for heat storage, but to minimize losses during day and night time only. The depth of phase change material over a fixed depth of water in a solar thermal collector is an important geometric parameter that influences the maximum temperature rise during peak solar irradiation and hence the losses. From the results of the studies for different masses of paraffin wax phase change material layers, the optimum depth corresponding to the maximum heat gain till evening is found to be 2 mm, and the heat retention till the next day morning is found to be 4 mm.

  20. Assessment of digital panoramic radiography's diagnostic value in angular bony lesions with 5 mm or deeper pocket depth in mandibular molars

    Directory of Open Access Journals (Sweden)

    Bardia Vadiati Saberi

    2017-01-01

    Conclusion: Based on this study, bone probing is a reliable method in vertical alveolar bone defect measurements. While the information obtained from digital panoramic radiographs should be used with caution and the ability of digital panoramic radiography in the determination of defect depth is limited.

  1. Strong-field Photoionization of Sputtered Neutral Molecules for Molecular Depth Profiling

    Science.gov (United States)

    Willingham, D; Brenes, D. A.; Wucher, A

    2009-01-01

    Molecular depth profiles of an organic thin film of guanine vapor deposited onto a Ag substrate are obtained using a 40 keV C60 cluster ion beam in conjunction with time-of-flight secondary ion mass spectrometric (ToF-SIMS) detection. Strong-field, femtosecond photoionization of intact guanine molecules is used to probe the neutral component of the profile for direct comparison with the secondary ion component. The ability to simultaneously acquire secondary ions and photoionized neutral molecules reveals new fundamental information about the factors that influence the properties of the depth profile. Results show that there is an increased ionization probability for protonated molecular ions within the first 10 nm due to the generation of free protons within the sample. Moreover, there is a 50% increase in fragment ion signal relative to steady state values 25 nm before reaching the guanine/Ag interface as a result of interfacial chemical damage accumulation. An altered layer thickness of 20 nm is observed as a consequence of ion beam induced chemical mixing. In general, we show that the neutral component of a molecular depth profile using the strong-field photoionization technique can be used to elucidate the effects of variations in ionization probability on the yield of molecular ions as well as to aid in obtaining accurate information about depth dependent chemical composition that cannot be extracted from TOF-SIMS data alone. PMID:20495665

  2. Efficient Depth Enhancement Using a Combination of Color and Depth Information.

    Science.gov (United States)

    Lee, Kyungjae; Ban, Yuseok; Lee, Sangyoun

    2017-07-01

    Studies on depth images containing three-dimensional information have been performed for many practical applications. However, the depth images acquired from depth sensors have inherent problems, such as missing values and noisy boundaries. These problems significantly affect the performance of applications that use a depth image as their input. This paper describes a depth enhancement algorithm based on a combination of color and depth information. To fill depth holes and recover object shapes, asynchronous cellular automata with neighborhood distance maps are used. Image segmentation and a weighted linear combination of spatial filtering algorithms are applied to extract object regions and fill disocclusion in the object regions. Experimental results on both real-world and public datasets show that the proposed method enhances the quality of the depth image with low computational complexity, outperforming conventional methods on a number of metrics. Furthermore, to verify the performance of the proposed method, we present stereoscopic images generated by the enhanced depth image to illustrate the improvement in quality.

  3. Eddy current testing probe with dual half-cylindrical coils

    Science.gov (United States)

    Bae, Byung-Hoon; Choi, Jung-Mi; Kim, Soo-Yong

    2000-02-01

    We have developed a new eddy current probe composed of a dual half-cylindrical (2HC) coil as an exciting coil and a sensing coil that is placed in the small gap of the 2HC coil. The 2HC coil induces a linear eddy current on the narrow region within the target medium. The magnitude of eddy current has a maximum peak with the narrow width, underneath the center of the exciting 2HC coil. Because of the linear eddy current, the probe can be used to detect not only the existence of a crack but also its direction in conducting materials. Using specimen with a machined crack, and varying the exciting frequency from 0.5 to 100 kHz, we investigated the relationships between the direction of crack and the output voltage of the sensing coil.

  4. Extending the fundamental imaging-depth limit of multi-photon microscopy by imaging with photo-activatable fluorophores.

    Science.gov (United States)

    Chen, Zhixing; Wei, Lu; Zhu, Xinxin; Min, Wei

    2012-08-13

    It is highly desirable to be able to optically probe biological activities deep inside live organisms. By employing a spatially confined excitation via a nonlinear transition, multiphoton fluorescence microscopy has become indispensable for imaging scattering samples. However, as the incident laser power drops exponentially with imaging depth due to scattering loss, the out-of-focus fluorescence eventually overwhelms the in-focal signal. The resulting loss of imaging contrast defines a fundamental imaging-depth limit, which cannot be overcome by increasing excitation intensity. Herein we propose to significantly extend this depth limit by multiphoton activation and imaging (MPAI) of photo-activatable fluorophores. The imaging contrast is drastically improved due to the created disparity of bright-dark quantum states in space. We demonstrate this new principle by both analytical theory and experiments on tissue phantoms labeled with synthetic caged fluorescein dye or genetically encodable photoactivatable GFP.

  5. Wave Loads on Ships Sailing in Restricted Water Depth

    DEFF Research Database (Denmark)

    Vidic-Perunovic, Jelena; Jensen, Jørgen Juncher

    2003-01-01

    depth for a container vessel. The results show that if the water depth is less than two times the draft of the vessel, the wave-induced bending moment becomes significant larger than in deep water with the same sea state description. The peak in the frequency response function for the wave bending......The wave-induced bending moment in ships is the most important sea load parameter for ships larger than 100m in length. Hence, any rational ship design procedure must include a reasonable accurate determination of this load and a large amount of various hydrodynamic formulations have been published......, ranging from semi-empirical formulas to three-dimensional non-linear procedures. A review of the state-of-the art can be found in ISSC.VI.1 (2000). These procedures must be combined with operational and sea state information to predict the probability distribution of the maximum wave-induced bending...

  6. Pulsed eddy current differential probe to detect the defects in a stainless steel pipe

    Science.gov (United States)

    Angani, C. S.; Park, D. G.; Kim, C. G.; Leela, P.; Kishore, M.; Cheong, Y. M.

    2011-04-01

    Pulsed eddy current (PEC) is an electromagnetic nondestructive technique widely used to detect and quantify the flaws in conducting materials. In the present study a differential Hall-sensor probe which is used in the PEC system has been fabricated for the detection of defects in stainless steel pipelines. The differential probe has an exciting coil with two Hall-sensors. A stainless steel test sample with electrical discharge machining (EDM) notches under different depths of 1-5 mm was made and the sample was laminated by plastic insulation having uniform thickness to simulate the pipelines in nuclear power plants (NPPs). The driving coil in the probe is excited by a rectangular current pulse and the resultant response, which is the difference of the two Hall-sensors, has been detected as the PEC probe signal. The discriminating time domain features of the detected pulse such as peak value and time to zero are used to interpret the experimental results with the defects in the test sample. A feature extraction technique such as spectral power density has been devised to infer the PEC response.

  7. Depth resolution and preferential sputtering in depth profiling of sharp interfaces

    International Nuclear Information System (INIS)

    Hofmann, S.; Han, Y.S.; Wang, J.Y.

    2017-01-01

    Highlights: • Interfacial depth resolution from MRI model depends on sputtering rate differences. • Depth resolution critically depends on the dominance of roughness or atomic mixing. • True (depth scale) and apparent (time scale) depth resolutions are different. • Average sputtering rate approximately yields true from apparent depth resolution. • Profiles by SIMS and XPS are different but similar to surface concentrations. - Abstract: The influence of preferential sputtering on depth resolution of sputter depth profiles is studied for different sputtering rates of the two components at an A/B interface. Surface concentration and intensity depth profiles on both the sputtering time scale (as measured) and the depth scale are obtained by calculations with an extended Mixing-Roughness-Information depth (MRI)-model. The results show a clear difference for the two extreme cases (a) preponderant roughness and (b) preponderant atomic mixing. In case (a), the interface width on the time scale (Δt(16–84%)) increases with preferential sputtering if the faster sputtering component is on top of the slower sputtering component, but the true resolution on the depth scale (Δz(16–84%)) stays constant. In case (b), the interface width on the time scale stays constant but the true resolution on the depth scale varies with preferential sputtering. For similar order of magnitude of the atomic mixing and the roughness parameters, a transition state between the two extremes is obtained. While the normalized intensity profile of SIMS represents that of the surface concentration, an additional broadening effect is encountered in XPS or AES by the influence of the mean electron escape depth which may even cause an additional matrix effect at the interface.

  8. Depth resolution and preferential sputtering in depth profiling of sharp interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, S. [Max Planck Institute for Intelligent Systems (formerly MPI for Metals Research), Heisenbergstrasse 3, D-70569 Stuttgart (Germany); Han, Y.S. [Department of Physics, Shantou University, 243 Daxue Road, Shantou, 515063 Guangdong (China); Wang, J.Y., E-mail: wangjy@stu.edu.cn [Department of Physics, Shantou University, 243 Daxue Road, Shantou, 515063 Guangdong (China)

    2017-07-15

    Highlights: • Interfacial depth resolution from MRI model depends on sputtering rate differences. • Depth resolution critically depends on the dominance of roughness or atomic mixing. • True (depth scale) and apparent (time scale) depth resolutions are different. • Average sputtering rate approximately yields true from apparent depth resolution. • Profiles by SIMS and XPS are different but similar to surface concentrations. - Abstract: The influence of preferential sputtering on depth resolution of sputter depth profiles is studied for different sputtering rates of the two components at an A/B interface. Surface concentration and intensity depth profiles on both the sputtering time scale (as measured) and the depth scale are obtained by calculations with an extended Mixing-Roughness-Information depth (MRI)-model. The results show a clear difference for the two extreme cases (a) preponderant roughness and (b) preponderant atomic mixing. In case (a), the interface width on the time scale (Δt(16–84%)) increases with preferential sputtering if the faster sputtering component is on top of the slower sputtering component, but the true resolution on the depth scale (Δz(16–84%)) stays constant. In case (b), the interface width on the time scale stays constant but the true resolution on the depth scale varies with preferential sputtering. For similar order of magnitude of the atomic mixing and the roughness parameters, a transition state between the two extremes is obtained. While the normalized intensity profile of SIMS represents that of the surface concentration, an additional broadening effect is encountered in XPS or AES by the influence of the mean electron escape depth which may even cause an additional matrix effect at the interface.

  9. Integrated ultrasound and gamma imaging probe for medical diagnosis

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Cinti, M. N.; Polito, C.; Orlandi, C.; Fabbri, A.; Vincentis, G. De

    2016-01-01

    In the last few years, integrated multi-modality systems have been developed, aimed at improving the accuracy of medical diagnosis correlating information from different imaging techniques. In this contest, a novel dual modality probe is proposed, based on an ultrasound detector integrated with a small field of view single photon emission gamma camera. The probe, dedicated to visualize small organs or tissues located at short depths, performs dual modality images and permits to correlate morphological and functional information. The small field of view gamma camera consists of a continuous NaI:Tl scintillation crystal coupled with two multi-anode photomultiplier tubes. Both detectors were characterized in terms of position linearity and spatial resolution performances in order to guarantee the spatial correspondence between the ultrasound and the gamma images. Finally, dual-modality images of custom phantoms are obtained highlighting the good co-registration between ultrasound and gamma images, in terms of geometry and image processing, as a consequence of calibration procedures

  10. Experimental evidence concerning the significant information depth of electron backscatter diffraction (EBSD)

    Energy Technology Data Exchange (ETDEWEB)

    Wisniewski, Wolfgang, E-mail: wolfgang.w@uni-jena.de [Otto-Schott-Institut, Jena University, Fraunhoferstr. 6, 07743 Jena (Germany); Saager, Stefan [Fraunhofer Institute for Organic Electronics, Electron Beam and Plasma Technology FEP, Winterbergstraße 28, 01277 Dresden (Germany); Böbenroth, Andrea [Fraunhofer Institute for the Microstructure of Materials and Systems IMWS, Walter-Huelse-Straße 1, 06120 Halle (Saale) (Germany); Rüssel, Christian [Otto-Schott-Institut, Jena University, Fraunhoferstr. 6, 07743 Jena (Germany)

    2017-02-15

    Experiments concerning the information depth of electron backscatter diffraction (EBSD) are performed on samples featuring an amorphous wedge on a crystalline substrate and a crystalline wedge on an amorphous substrate. The effects of the acceleration voltage and exemplary software settings on the ability to measure through an amorphous layer are presented. Changes in the EBSD-signal could be detected through a ≈142 nm thick layer of amorphous Si while orientation measurements could be performed through a ≈116 nm thick layer when using a voltage of 30 kV. The complexity of the information depth significant to a given EBSD-pattern and the multiple parameters influencing it are discussed. It is suggested that a “core information depth” is significant to high quality patterns while a larger “maximum information depth” becomes relevant when the pattern quality decreases or the sample is inhomogeneous within the information volume, i.e. in the form of partially crystalline materials or crystal layers in the nm scale. - Highlights: • Experimental evidence of the significant information depth of EBSD is presented. • Effects of the voltage and exemplary software settings are discussed. • Dependence of the significant information depth on the pattern quality is proposed. • The information depth may reach up to 142 nm in Si when using a voltage of 30 kV. • The information depth depends on the available technology.

  11. Estimation of foot pressure from human footprint depths using 3D scanner

    Science.gov (United States)

    Wibowo, Dwi Basuki; Haryadi, Gunawan Dwi; Priambodo, Agus

    2016-03-01

    The analysis of normal and pathological variation in human foot morphology is central to several biomedical disciplines, including orthopedics, orthotic design, sports sciences, and physical anthropology, and it is also important for efficient footwear design. A classic and frequently used approach to study foot morphology is analysis of the footprint shape and footprint depth. Footprints are relatively easy to produce and to measure, and they can be preserved naturally in different soils. In this study, we need to correlate footprint depth with corresponding foot pressure of individual using 3D scanner. Several approaches are used for modeling and estimating footprint depths and foot pressures. The deepest footprint point is calculated from z max coordinate-z min coordinate and the average of foot pressure is calculated from GRF divided to foot area contact and identical with the average of footprint depth. Evaluation of footprint depth was found from importing 3D scanner file (dxf) in AutoCAD, the z-coordinates than sorted from the highest to the lowest value using Microsoft Excel to make footprinting depth in difference color. This research is only qualitatif study because doesn't use foot pressure device as comparator, and resulting the maximum pressure on calceneus is 3.02 N/cm2, lateral arch is 3.66 N/cm2, and metatarsal and hallux is 3.68 N/cm2.

  12. The coefficient of friction of chrysotile gouge at seismogenic depths

    Science.gov (United States)

    Moore, Diane E.; Lockner, D.A.; Tanaka, H.; Iwata, K.

    2004-01-01

    We report new strength data for the serpentine mineral chrysotile at effective normal stresses, ??sn between 40 and 200 MPa in the temperature range 25??-280??C. Overall, the coefficient of friction, ?? (= shear stress/effective normal stress) of water-saturated chrysotile gouge increases both with increasing temperature and ??sn, but the rates vary and the temperature-related increases begin at ???100??C. As a result, a frictional strength minimum (?? = 0.1) occurs at low ??sn at about 100??C. Maximum strength (?? = 0.55) results from a combination of high normal stress and high temperature. The low-strength region is characterized by velocity strengthening and the high-strength region by velocity-weakening behavior. Thoroughly dried chrysotile has ?? = 0.7 and is velocity-weakening. The frictional properties of chrysolite can be explained in its tendency to adsorb large amounts of water that acts as a lubricant during shear. The water is progressively driven off the fiber surfaces with increasing temperature and pressure, causing chrysotile to approach its dry strength. Depth profiles for a chrysotile-lined fault constructed from these data would pass through a strength minimum at ???3 km depth, where sliding should be stable. Below that depth, strength increases rapidly as does the tendency for unstable (seismic) slip. Such a trend would not have been predicted from the room-temperature data. These results therefore illustrate the potential hazards of extrapolating room-temperature friction data to predict fault zone behavior at depth. This depth profile for chrysotile is consistent with the pattern of slip on the Hayward fault, which creeps aseismically at shallow depths but which may be locked below 5 km depth. ?? 2004 by V. H. Winston and Son, Inc. All rights reserved.

  13. Measuring the surface-heating of medical ultrasonic probes

    International Nuclear Information System (INIS)

    Kollmann, Chr; Vacariu, G; Fialka-Moser, V; Bergmann, H

    2004-01-01

    Due to converting losses the probe's surface itself is heated up, especially when emitting into air. Possible temperature increases in an ensemble of 15 different diagnostic and therapeutic ultrasound probes from 7 manufacturers in the frequency range between 0.05-7.5 MHz have been examined. Surface temperatures were detected by means of a calibrated IR-thermographic camera using a scheme of various power and pulse settings, as well as different imaging modalitites as used in clinical routine. Depending on the setup and the output power, the absolute surface temperatures of some of the probes emitting in air can be beyond 43 deg. C within 5-7 min.; a maximum surface temperature of 84 deg. C has been detected. Continuous mode or high pulse repetition frequencies on the therapeutic system side, small focused Doppler modes on the diagnostic system side combined with increased emitted acoustic intensities result in high surface temperatures. Within a worst case scenario a potential risk of negative skin changes (heat damage) or non-optimal therapeutic effects seems to be possible if a therapeutic system is used very often and if its emission continues unintentionally. In general the user should be aware that low emission intensities of e.g. 50 mW cm -2 could already produce hot surfaces

  14. Temperature-referenced high-sensitivity point-probe optical fiber chem-sensors based on cladding etched fiber Bragg gratings

    OpenAIRE

    Zhou, Kaiming; Chen, Xianfeng F.; Zhang, Lin; Bennion, Ian

    2004-01-01

    Point-probe optical fiber chem-sensors have been implemented using cladding etched fiber Bragg gratings. The sensors possess refractive index sensing capability that can be utilized to measure chemical concentrations. The Bragg wavelength shift reaches 8 nm when the index of surrounding medium changes from 1.33 to 1.44, giving maximum sensitivity more than 10 times higher than that of previously reported devices. More importantly, the dual-grating configuration of the point-probe sensors offe...

  15. Knee Joint Kinetics in Relation to Commonly Prescribed Squat Loads and Depths

    Science.gov (United States)

    Cotter, Joshua A.; Chaudhari, Ait M.; Jamison, Steve T.; Devor, Steven T.

    2014-01-01

    Controversy exists regarding the safety and performance benefits of performing the squat exercise to depths beyond 90° of knee flexion. Our aim was to compare the net peak external knee flexion moments (pEKFM) experienced over typical ranges of squat loads and depths. Sixteen recreationally trained males (n = 16; 22.7 ± 1.1 yrs; 85.4 ± 2.1 kg; 177.6 ± 0.96 cm; mean ± SEM) with no previous lower limb surgeries or other orthopedic issues and at least one year of consistent resistance training experience while utilizing the squat exercise performed single repetition squat trials in a random order at squat depths of above parallel, parallel, and below parallel. Less than one week before testing, one repetition maximum (1RM) values were found for each squat depth. Subsequent testing required subjects to perform squats at the three depths with three different loads: unloaded, 50% 1RM, and 85% 1RM (nine total trials). Force platform and kinematic data were collected to calculate pEKFM. To assess differences among loads and depths, a two-factor (load and depth) repeated-measures ANOVA with significance set at the P Squat 1RM significantly decreased 13.6% from the above parallel to parallel squat and another 3.6% from the parallel to the below parallel squat (P squat depth and load were increased (P ≤ 0.02). Slopes of pEKFM were greater from unloaded to 50% 1RM than when progressing from 50% to 85% 1RM (P squat loads used with increasing depths are not enough to offset increases in pEKFM. PMID:23085977

  16. Four-probe measurements with a three-probe scanning tunneling microscope

    International Nuclear Information System (INIS)

    Salomons, Mark; Martins, Bruno V. C.; Zikovsky, Janik; Wolkow, Robert A.

    2014-01-01

    We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe

  17. Four-probe measurements with a three-probe scanning tunneling microscope

    Energy Technology Data Exchange (ETDEWEB)

    Salomons, Mark [National Institute for Nanotechnology, National Research Council of Canada, Edmonton, Alberta T6G 2M9 (Canada); Martins, Bruno V. C.; Zikovsky, Janik; Wolkow, Robert A., E-mail: rwolkow@ualberta.ca [National Institute for Nanotechnology, National Research Council of Canada, Edmonton, Alberta T6G 2M9 (Canada); Department of Physics, University of Alberta, Edmonton, Alberta T6G 2E1 (Canada)

    2014-04-15

    We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe.

  18. Four-probe measurements with a three-probe scanning tunneling microscope.

    Science.gov (United States)

    Salomons, Mark; Martins, Bruno V C; Zikovsky, Janik; Wolkow, Robert A

    2014-04-01

    We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe.

  19. Real-time depth monitoring and control of laser machining through scanning beam delivery system

    International Nuclear Information System (INIS)

    Ji, Yang; Grindal, Alexander W; Fraser, James M; Webster, Paul J L

    2015-01-01

    Scanning optics enable many laser applications in manufacturing because their low inertia allows rapid movement of the process beam across the sample. We describe our method of inline coherent imaging for real-time (up to 230 kHz) micron-scale (7–8 µm axial resolution) tracking and control of laser machining depth through a scanning galvo-telecentric beam delivery system. For 1 cm trench etching in stainless steel, we collect high speed intrapulse and interpulse morphology which is useful for further understanding underlying mechanisms or comparison with numerical models. We also collect overall sweep-to-sweep depth penetration which can be used for feedback depth control. For trench etching in silicon, we show the relationship of etch rate with average power and scan speed by computer processing of depth information without destructive sample post-processing. We also achieve three-dimensional infrared continuous wave (modulated) laser machining of a 3.96 × 3.96 × 0.5 mm 3 (length × width × maximum depth) pattern on steel with depth feedback. To the best of our knowledge, this is the first successful demonstration of direct real-time depth monitoring and control of laser machining with scanning optics. (paper)

  20. Mesophotic coral depth acclimatization is a function of host-specific symbiont physiology

    KAUST Repository

    Ziegler, Maren

    2015-02-06

    Mesophotic coral ecosystems receive increasing attention owing to their potential as deep coral refuges in times of global environmental change. Here, the mechanisms of coral holobiont photoacclimatization over a 60 m depth gradient in the central Red Sea were examined for the four coral genera Porites, Leptoseris, Pachyseris, and Podabacia. General acclimatization strategies were common to all host-symbiont combinations, e.g., Symbiodinium cell densities and photoprotective (PP) to light-harvesting pigment ratios both significantly decreased with water depth. Porites harbored Symbiodinium type C15 over the whole 60 m depth range, while Pachyseris and Podabacia had limited vertical distributions and hosted mainly Symbiodinium type C1. Symbiodinium type C15 had generally higher xanthophyll de-epoxidation rates and lower maximum quantum yields than C1, and also exhibited a strong photoacclimatory signal over depth that relates to the large distribution range of Porites. Interestingly, the coral host had an effect on Symbiodinium pigment composition. When comparing Symbiodinium type C1 in Podabacia and Pachyseris, the ß-carotene chl a−1, the peridinin chl a−1, and diadinoxanthin chl a−1 ratios were significantly different between host species. Our data support a view that depth acclimatization of corals in the mesophotics is facilitated by Symbiodinium physiology, which in turn is host-specific.

  1. Mesophotic coral depth acclimatization is a function of host-specific symbiont physiology

    KAUST Repository

    Ziegler, Maren; Roder, Cornelia; Bü chel, Claudia; Voolstra, Christian R.

    2015-01-01

    Mesophotic coral ecosystems receive increasing attention owing to their potential as deep coral refuges in times of global environmental change. Here, the mechanisms of coral holobiont photoacclimatization over a 60 m depth gradient in the central Red Sea were examined for the four coral genera Porites, Leptoseris, Pachyseris, and Podabacia. General acclimatization strategies were common to all host-symbiont combinations, e.g., Symbiodinium cell densities and photoprotective (PP) to light-harvesting pigment ratios both significantly decreased with water depth. Porites harbored Symbiodinium type C15 over the whole 60 m depth range, while Pachyseris and Podabacia had limited vertical distributions and hosted mainly Symbiodinium type C1. Symbiodinium type C15 had generally higher xanthophyll de-epoxidation rates and lower maximum quantum yields than C1, and also exhibited a strong photoacclimatory signal over depth that relates to the large distribution range of Porites. Interestingly, the coral host had an effect on Symbiodinium pigment composition. When comparing Symbiodinium type C1 in Podabacia and Pachyseris, the ß-carotene chl a−1, the peridinin chl a−1, and diadinoxanthin chl a−1 ratios were significantly different between host species. Our data support a view that depth acclimatization of corals in the mesophotics is facilitated by Symbiodinium physiology, which in turn is host-specific.

  2. An experimental study of simultaneous ablation with dual probes in radiofrequency thermal ablation

    International Nuclear Information System (INIS)

    Jang, Il Soo; Rhim, Hyun Chul; Koh, Byung Hee; Cho, On Koo; Seo, Heung Suk; Kim, Yong Soo; Kim, Young Sun; Heo, Jeong Nam

    2003-01-01

    To determine the differences between sequential ablation with a single probe and simultaneous ablation with dual probes. Using two 14-gauge expandable probes (nine internal prongs with 4-cm deployment), radiofrequency was applied sequentially (n=8) or simultaneously (n=8) to ten ex-vivo cow livers. Before starting ablation, two RF probes with an inter-probe space of 2 cm (n=8) or 3 cm (n=8) were inserted. In the sequential group, switching the connecting cable to an RF generator permitted ablation with the second probe just after ablation with the first probe had finished. In the simultaneous group, single ablation was performed only after connecting the shafts of both RF probes using a connection device. Each ablation lasted 7 minutes at a target temperature of 105-110 .deg. C. The size and shape of the ablated area, and total ablation time were then compared between the two groups. With 2-cm spacing, the group, mean length and overlapping width of ablated lesions were, respectively, 5.20 and 5.05 cm in the sequential group (n=4), and 5.81 and 5.65 cm in the simultaneous group (n=4). With 3-cm spacing, the corresponding figures were 4.99 and 5.60 cm in the sequential group (n=4), and 6.04 and 6.78 cm in the simultaneous group (n=4). With 2-cm spacing, the mean depth of the proximal waist was 0.58 cm in the sequential (group and 0.28 cm in the simultaneous group, while with 3-cm spacing, the corresponding figures were 1.65 and 1.48 cm. In neither group was there a distal waist. Mean total ablation time was 23.4 minutes in the sequential group and 14 minutes in the simultaneous group. In terms of ablation size and ablation time, simultaneous radiofrequency ablation with dual probes is superior to sequential ablation with a single probe. A simultaneous approach will enable an operator to overcome difficulty in probe repositioning during overlapping ablation, resulting in complete ablation with a successful safety margin

  3. Determination of crack depth in aluminum using eddy currents and GMR sensors

    Science.gov (United States)

    Lopes Ribeiro, A.; Pasadas, D.; Ramos, H. G.; Rocha, T.

    2015-03-01

    In this paper we use eddy currents to determine the depth of linear cracks in aluminum plates. A constant field probe is used to generate the spatially uniform excitation field and a single axis giant magneto-resistor (GMR) sensor is used to measure the eddy currents magnetic field. Different depths were machined in one aluminum plate with 4 mm of thickness. By scanning those cracks the magnetic field components parallel and perpendicular to the crack's line were measured when the eddy currents were launched perpendicularly to the crack's line. To characterize one crack in a plate of a given thickness and material, the experimental procedure was defined. The plate surface is scanned to detect and locate one crack. The acquired data enables the determination of the crack's length and orientation. A second scanning is performed with the excitation current perpendicular to the crack and the GMR sensing axis perpendicular and parallel to the crack's line.

  4. Depth of cure of bulk-fill flowable composite resins.

    Science.gov (United States)

    Pedalino, Inaam; Hartup, Grant R; Vandewalle, Kraig S

    2015-01-01

    In recent years, manufacturers have introduced flowable composite resins that reportedly can be placed in increments of 4 mm or greater. The purpose of this study was to evaluate the depth of cure of bulk-fill flowable composite resins (SureFil SDR Flow, Grandio Flow, and Venus Bulk Fill) and a conventional flowable composite resin (Revolution Formula 2). Depth of cure was measured in terms of bottom-maximum Knoop hardness number (KHN) ratios and the International Organization for Standardization (ISO) 4049 scrape technique. Shades A2 and A3 of SureFil SDR Flow, Grandio Flow, and Revolution Formula 2 were tested. Venus Bulk Fill was tested in its only available shade (universal). Specimens in thicknesses of 2, 3, 4, 5, and 6 mm were polymerized for 20 or 40 seconds, and a hardness tester was used to determine the hardness ratios for each shade at each thickness. For the scraping technique, after specimens were exposed to the curing light, unpolymerized composite resin was removed with a plastic instrument, the polymerized composite was measured, and the length was divided by 2 per ISO guidelines. According to the KHN ratios and the scrape test, Venus Bulk Fill predictably exceeded the manufacturer's claim of a 4-mm depth of cure at both 20 and 40 seconds of curing time. The overall results for depth of cure showed that Venus Bulk Fill ≥ SureFil SDR Flow ≥ Grandio Flow ≥ Revolution Formula 2.

  5. Mobile Game Probes

    DEFF Research Database (Denmark)

    Borup Lynggaard, Aviaja

    2006-01-01

    This paper will examine how probes can be useful for game designers in the preliminary phases of a design process. The work is based upon a case study concerning pervasive mobile phone games where Mobile Game Probes have emerged from the project. The new probes are aimed towards a specific target...... group and the goal is to specify the probes so they will cover the most relevant areas for our project. The Mobile Game Probes generated many interesting results and new issues occurred, since the probes came to be dynamic and favorable for the process in new ways....

  6. Predicting Maximum Lake Depth from Surrounding Topography

    Science.gov (United States)

    Lake volume aids understanding of the physical and ecological dynamics of lakes, yet is often not readily available. The data needed to calculate lake volume (i.e. bathymetry) are usually only collected on a lake by lake basis and are difficult to obtain across broad regions. ...

  7. Possible concepts for an in situ Saturn probe mission

    Science.gov (United States)

    Coustenis, Athena; Lebreton, Jean-Pierre; Mousis, Olivier; Atkinson, David H.; Lunine, Jonathan I.; Reh, Kim R.; Fletcher, Leigh N.; Simon-Miller, Amy A.; Atreya, Sushil; Brinckerhoff, William B.; Cavalie, Thibault; Colaprete, Anthony; Gautier, Daniel; Guillot, Tristan; Mahaffy, Paul R.; Marty, Bernard; Morse, Andy; Sims, Jon; Spilker, Tom; Spilker, Linda

    2014-05-01

    In situ exploration of Saturn's atmosphere would bring insights in two broad themes: the formation history of our solar system and the processes at play in planetary atmospheres. The science case for in situ measurements at Saturn are developed in [1] and two companion abstracts (see Mousis et al., and Atkinson et al.). They are summarized here. Measurements of Saturn's bulk chemical and isotopic composition would place important constraints on the volatile reservoirs in the protosolar nebula and hence on the formation mechanisms. An in situ probe, penetrating from the upper atmosphere (μbar level) into the convective weather layer to a minimum depth of 10 bar, would also contribute to our knowledge of Saturn's atmospheric structure, dynamics, composition, chemistry and cloud-forming processes. Different mission architectures are envisaged, all based on an entry probe that would descend through Saturn's stratosphere and troposphere under parachute down to a minimum of 10 bars [1]. Future studies will focus on the trade-offs between science return and the added design complexity of a probe that could operate at pressures larger than 10 bars. Accelerometry measurements may also be performed during the entry phase in the higher part of the stratosphere prior to starting measurements under parachute. A carrier system would be required to deliver the probe along its interplanetary trajectory to the desired atmospheric entry point at Saturn. The entry site would be carefully selected. Three possible mission configurations are currently under study (with different risk/cost trades): • Configuration 1: Probe + Carrier. After probe delivery, the carrier would follow its path and be destroyed during atmospheric entry, but could perform pre-entry science. The carrier would not be used as a radio relay, but the probe would transmit its data to the ground system via a direct-to-Earth (DTE) RF link; • Configuration 2: Probe + Carrier/Relay. The probe would detach from the

  8. Standard values of maximum tongue pressure taken using newly developed disposable tongue pressure measurement device.

    Science.gov (United States)

    Utanohara, Yuri; Hayashi, Ryo; Yoshikawa, Mineka; Yoshida, Mitsuyoshi; Tsuga, Kazuhiro; Akagawa, Yasumasa

    2008-09-01

    It is clinically important to evaluate tongue function in terms of rehabilitation of swallowing and eating ability. We have developed a disposable tongue pressure measurement device designed for clinical use. In this study we used this device to determine standard values of maximum tongue pressure in adult Japanese. Eight hundred fifty-three subjects (408 male, 445 female; 20-79 years) were selected for this study. All participants had no history of dysphagia and maintained occlusal contact in the premolar and molar regions with their own teeth. A balloon-type disposable oral probe was used to measure tongue pressure by asking subjects to compress it onto the palate for 7 s with maximum voluntary effort. Values were recorded three times for each subject, and the mean values were defined as maximum tongue pressure. Although maximum tongue pressure was higher for males than for females in the 20-49-year age groups, there was no significant difference between males and females in the 50-79-year age groups. The maximum tongue pressure of the seventies age group was significantly lower than that of the twenties to fifties age groups. It may be concluded that maximum tongue pressures were reduced with primary aging. Males may become weaker with age at a faster rate than females; however, further decreases in strength were in parallel for male and female subjects.

  9. A Ratiometric Acoustogenic Probe for in Vivo Imaging of Endogenous Nitric Oxide.

    Science.gov (United States)

    Reinhardt, Christopher J; Zhou, Effie Y; Jorgensen, Michael D; Partipilo, Gina; Chan, Jefferson

    2018-01-24

    Photoacoustic (PA) imaging is an emerging imaging modality that utilizes optical excitation and acoustic detection to enable high resolution at centimeter depths. The development of activatable PA probes can expand the utility of this technology to allow for detection of specific stimuli within live-animal models. Herein, we report the design, development, and evaluation of a series of Acoustogenic Probe(s) for Nitric Oxide (APNO) for the ratiometric, analyte-specific detection of nitric oxide (NO) in vivo. The best probe in the series, APNO-5, rapidly responds to NO to form an N-nitroso product with a concomitant 91 nm hypsochromic shift. This property enables ratiometric PA imaging upon selective irradiation of APNO-5 and the corresponding product, tAPNO-5. Moreover, APNO-5 displays the requisite photophysical characteristics for in vivo PA imaging (e.g., high absorptivity, low quantum yield) as well as high biocompatibility, stability, and selectivity for NO over a variety of biologically relevant analytes. APNO-5 was successfully applied to the detection of endogenous NO in a murine lipopolysaccharide-induced inflammation model. Our studies show a 1.9-fold increase in PA signal at 680 nm and a 1.3-fold ratiometric turn-on relative to a saline control.

  10. Traversing probe system

    Science.gov (United States)

    Mashburn, Douglas N.; Stevens, Richard H.; Woodall, Harold C.

    1977-01-01

    This invention comprises a rotatable annular probe-positioner which carries at least one radially disposed sensing probe, such as a Pitot tube having a right-angled tip. The positioner can be coaxially and rotatably mounted within a compressor casing or the like and then actuated to orient the sensing probe as required to make measurements at selected stations in the annulus between the positioner and compressor casing. The positioner can be actuated to (a) selectively move the probe along its own axis, (b) adjust the yaw angle of the right-angled probe tip, and (c) revolve the probe about the axis common to the positioner and casing. A cam plate engages a cam-follower portion of the probe and normally rotates with the positioner. The positioner includes a first-motor-driven ring gear which effects slidable movement of the probe by rotating the positioner at a time when an external pneumatic cylinder is actuated to engage the cam plate and hold it stationary. When the pneumatic cylinder is not actuated, this ring gear can be driven to revolve the positioner and thus the probe to a desired circumferential location about the above-mentioned common axis. A second motor-driven ring gear included in the positioner can be driven to rotate the probe about its axis, thus adjusting the yaw angle of the probe tip. The positioner can be used in highly corrosive atmosphere, such as gaseous uranium hexafluoride.

  11. Traversing probe system

    International Nuclear Information System (INIS)

    Mashburn, D.N.; Stevens, R.H.; Woodall, H.C.

    1977-01-01

    This invention comprises a rotatable annular probe-positioner which carries at least one radially disposed sensing probe, such as a Pitot tube having a right-angled tip. The positioner can be coaxially and rotatably mounted within a compressor casing or the like and then actuated to orient the sensing probe as required to make measurements at selected stations in the annulus between the positioner and compressor casing. The positioner can be actuated to (a) selectively move the probe along its own axis, (b) adjust the yaw angle of the right-angled probe tip, and (c) revolve the probe about the axis common to the positioner and casing. A cam plate engages a cam-follower portion of the probe and normally rotates with the positioner. The positioner includes a first-motor-driven ring gear which effects slidable movement of the probe by rotating the positioner at a time when an external pneumatic cylinder is actuated to engage the cam plate and hold it stationary. When the pneumatic cylinder is not actuated, this ring gear can be driven to revolve the positioner and thus the probe to a desired circumferential location about the above-mentioned common axis. A second motor-driven ring gear included in the positioner can be driven to rotate the probe about its axis, thus adjusting the yaw angle of the probe tip. The positioner can be used in highly corrosive atmosphere, such as gaseous uranium hexafluoride. 10 claims, 6 figures

  12. Influence of probe geometry on the response of an electrostatic probe

    DEFF Research Database (Denmark)

    Johansson, Torben; Crichton, George C; McAllister, Iain Wilson

    1999-01-01

    The response of an electrostatic probe is examined with reference to the probe geometry. The study involves the evaluation of the probe lambda function, from which response-related characteristic parameters can be derived. These parameters enable the probe detection sensitivity Se and spatial...

  13. Depth profile of strain and composition in Si/Ge dot multilayers by microscopic phonon Raman spectroscopy

    International Nuclear Information System (INIS)

    Tan, P.H.; Bougeard, D.; Abstreiter, G.; Brunner, K.

    2005-01-01

    We characterized strain and Ge content depending on depth in a self-assembled Si/Ge dot multilayer by scanning a microscopic Raman probe at a (110) cleavage plane. The multilayer structure was deposited by molecular-beam epitaxy on a (001) Si substrate and consisted of 80 periods, each of them composed by 25 nm Si spacers and 8 monolayer Ge forming laterally and vertically uncorrelated islands with a height of 2 nm and a lateral diameter of about 20 nm. An average biaxial strain of -3.5% within the core regions of islands is determined from the splitting of longitudinal and transversal optical Ge-Ge phonon modes observed in polarized Raman measurements. The absolute mode frequencies further enable analysis of a Ge content of 0.82. The analyzed strain and composition of islands are nearly independent from depths below the sample surface. This indicates well-controlled deposition parameters and negligible intermixing during deposition of subsequent layers. These Raman results are in agreement with x-ray diffraction data. Small, local Raman frequency shifts were observed and discussed with respect to partial elastic strain relaxation of the multilayer stack after cleavage, undefined Raman-scattering geometries at the sample edge, and local heating by the laser probe

  14. Probing neural tissue with airy light-sheet microscopy: investigation of imaging performance at depth within turbid media

    Science.gov (United States)

    Nylk, Jonathan; McCluskey, Kaley; Aggarwal, Sanya; Tello, Javier A.; Dholakia, Kishan

    2017-02-01

    Light-sheet microscopy (LSM) has received great interest for fluorescent imaging applications in biomedicine as it facilitates three-dimensional visualisation of large sample volumes with high spatiotemporal resolution whilst minimising irradiation of, and photo-damage to the specimen. Despite these advantages, LSM can only visualize superficial layers of turbid tissues, such as mammalian neural tissue. Propagation-invariant light modes have played a key role in the development of high-resolution LSM techniques as they overcome the natural divergence of a Gaussian beam, enabling uniform and thin light-sheets over large distances. Most notably, Bessel and Airy beam-based light-sheet imaging modalities have been demonstrated. In the single-photon excitation regime and in lightly scattering specimens, Airy-LSM has given competitive performance with advanced Bessel-LSM techniques. Airy and Bessel beams share the property of self-healing, the ability of the beam to regenerate its transverse beam profile after propagation around an obstacle. Bessel-LSM techniques have been shown to increase the penetration-depth of the illumination into turbid specimens but this effect has been understudied in biologically relevant tissues, particularly for Airy beams. It is expected that Airy-LSM will give a similar enhancement over Gaussian-LSM. In this paper, we report on the comparison of Airy-LSM and Gaussian-LSM imaging modalities within cleared and non-cleared mouse brain tissue. In particular, we examine image quality versus tissue depth by quantitative spatial Fourier analysis of neural structures in virally transduced fluorescent tissue sections, showing a three-fold enhancement at 50 μm depth into non-cleared tissue with Airy-LSM. Complimentary analysis is performed by resolution measurements in bead-injected tissue sections.

  15. Probing and Tapping: Are We Inserting Pedicle Screws Correctly?

    Science.gov (United States)

    Prasad, Vishal; Mesfin, Addisu; Lee, Robert; Reigrut, Julie; Schmidt, John

    2016-11-01

    Although there are a significant number of research publications on the topic of bone morphology and the strength of bone, the clinical significance of a failed pedicle screw is often revision surgery and the potential for further postoperative complications; especially in elderly patients with osteoporotic bone. The purpose of this report is to quantify the mechanical strength of the foam-screw interface by assessing probe/pilot hole diameter and tap sizes using statistically relevant sample sizes under highly controlled test conditions. The study consisted of two experiments and used up to three different densities of reference-grade polyurethane foam (ASTM 1839), including 0.16, 0.24, and 0.32 g/cm 3 . All screws and rods were provided by K2M Inc. and screws were inserted to a depth of 25 mm. A series of pilot holes, 1.5, 2.2, 2.7, 3.2, 3.7, 4.2, 5.0, and 6.0 mm in diameter were drilled through the entire depth of the material. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 720). A 3.0-mm pilot hole was drilled and tapped with: no tap, 3.5-, 4.5-, 5.5-, and 6.5-mm taps. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 300). The size of the probe/pilot hole had a nonlinear, parabolic effect on pullout strength. This shape suggests an optimum-sized probe hole for a given size pedicle screw. Too large or too small of a probe hole causes a rapid falloff in pullout strength. The tap data demonstrated that not tapping and undertapping by two or three sizes did not significantly alter the pullout strength of the screws. The data showed an exponential falloff of pullout strength when as tap size increased to the diameter of the screw. In the current study, the data show that an ideal pilot hole size half the diameter of the screw is a starting point. Also, that if tapping was necessary, to use a tap two sizes smaller than the screw being implanted. A similar optimum pilot hole or tap size may be

  16. Simulation and experiment for depth sizing of cracks in anchor bolts by ultrasonic phased array technology

    Science.gov (United States)

    Lin, Shan

    2018-04-01

    There have been lots of reports about the occurrence of cracks in bolts in aging nuclear and thermal power plants. Sizing of such cracks is crucial for assessing the integrity of bolts. Currently, hammering and visual tests are used to detect cracks in bolts. However, they are not applicable for sizing cracks. Although the tip diffraction method is well known as a crack sizing technique, reflection echoes from threads make it difficult to apply this technique to bolts. This paper addresses a method for depth sizing of cracks in bolts by means of ultrasonic phased array technology. Numerical results of wave propagation in bolts by the finite element method (FEM) shows that a peak associated within the vicinity of a crack tip can be observed in the curve of echo intensity versus refraction angle for deep cracks. The refraction angle with respect to this peak decreases as crack depth increases. Such numerical results are verified by experiments on bolt specimens that have electrical discharge machining notches or fatigue cracks with different depths. In the experiment, a 10-MHz linear array probe is used. Depth of cracks in bolts using the refraction angle associated with the peak is determined and compared to actual depths. The comparison shows that accurately determining a crack depth from the inspection results is possible.

  17. What Can Radiocarbon Depth Profiles Tell Us About The LGM Circulation?

    Science.gov (United States)

    Burke, A.; Stewart, A.; Adkins, J. F.; Ferrari, R. M.; Thompson, A. F.; Jansen, M. F.

    2014-12-01

    Published reconstructions of radiocarbon in the Atlantic sector of the Southern Ocean indicate that there is a mid-depth maximum in radiocarbon age during the last glacial maximum (LGM). This is in contrast to the modern ocean where intense mixing between water masses along shared density surfaces (isopycnals) results in a relatively homogenous radiocarbon profile. A recent study (Ferrari et al. 2014) suggested that the extended Antarctic sea ice cover during the LGM necessitated a shallower boundary between the upper and lower branches of the meridional overturning circulation (MOC). This shoaled boundary lay above major topographic features and their associated strong diapycnal mixing, which isolated dense southern-sourced water in the lower branch of the overturning circulation. This isolation would have allowed radiocarbon to decay, and thus provides a possible explanation for the mid-depth radiocarbon age bulge. We test this hypothesis using an idealized, 2D, residual-mean dynamical model of the global overturning circulation. Concentration distributions of a decaying tracer that is advected by the simulated overturning are compared to published radiocarbon data. We test the sensitivity of the mid-depth radiocarbon age to changes in sea ice extent, wind strength, and isopycnal and diapycnal diffusion. The mid-depth radiocarbon age bulge is most likely caused by the different circulation geometry, associated with increased sea ice extent. In particular, with an LGM-like sea ice extent the upper and lower branches of the MOC no longer share isopycnals, so radiocarbon-rich northern-sourced water is no longer mixed rapidly into the southern-sourced water. However, this process alone cannot explain the magnitude of the glacial radiocarbon anomalies; additional isolation (e.g. from reduced air-sea gas exchange associated with the increased sea ice) is required. Ferrari, R., M. F. Jansen, J. F. Adkins, A. Burke, A. L. Stewart, and A. F. Thompson (2014), Antarctic sea

  18. The Oxford Probe: an open access five-hole probe for aerodynamic measurements

    Science.gov (United States)

    Hall, B. F.; Povey, T.

    2017-03-01

    The Oxford Probe is an open access five-hole probe designed for experimental aerodynamic measurements. The open access probe can be manufactured by the end user via additive manufacturing (metal or plastic). The probe geometry, drawings, calibration maps, and software are available under a creative commons license. The purpose is to widen access to aerodynamic measurement techniques in education and research environments. There are many situations in which the open access probe will allow results of comparable accuracy to a well-calibrated commercial probe. We discuss the applications and limitations of the probe, and compare the calibration maps for 16 probes manufactured in different materials and at different scales, but with the same geometrical design.

  19. The Oxford Probe: an open access five-hole probe for aerodynamic measurements

    International Nuclear Information System (INIS)

    Hall, B F; Povey, T

    2017-01-01

    The Oxford Probe is an open access five-hole probe designed for experimental aerodynamic measurements. The open access probe can be manufactured by the end user via additive manufacturing (metal or plastic). The probe geometry, drawings, calibration maps, and software are available under a creative commons license. The purpose is to widen access to aerodynamic measurement techniques in education and research environments. There are many situations in which the open access probe will allow results of comparable accuracy to a well-calibrated commercial probe. We discuss the applications and limitations of the probe, and compare the calibration maps for 16 probes manufactured in different materials and at different scales, but with the same geometrical design. (paper)

  20. Variation in Depth Dose Data between Open and Wedge Fields for 6 MV X-Rays

    International Nuclear Information System (INIS)

    U, Hong; Ryu, M. S. Samuel; Park, In Kyu

    1989-01-01

    Central axis depth dose data for 6 MV X-rays, including tissue maximum ratios, were measured for wedge fields according to Tatcher equation. In wedge fields, the differences in magnitude which increased with depth, field size, and wedge thickness increased when compared with the corresponding open field data. However, phantom scatter correction factors for wedge fields differed less that 1% from the corresponding open field factors. The differences in central axis percent depth dose between two types of fields indicated beam hardening by the wedge filter. The deviation of percent depth doses and scatter correction factors between the effective wedge field and the nominal wedge field at same angle was negligible. The differences were less than 3.26% between the nominal or effective wedge fields and the open fields for percent depth doses to the depth 7cm in 6cm x 6cm field. For larger (10cm x 10cm) field size, however, the deviation of percent depth doses between the nominal or effective wedge fields and the open fields were greater-dosimetric errors were 3.56% at depth 7cm and nearly 5.30% at 12cm. We suggest that the percent depth doses of individual wedge and wedge transmission factors should be considered for the dose calculation or monitor setting in the treatment of deep seated tumor

  1. Depth estimation of laser glass drilling based on optical differential measurements of acoustic response

    Science.gov (United States)

    Gorodesky, Niv; Ozana, Nisan; Berg, Yuval; Dolev, Omer; Danan, Yossef; Kotler, Zvi; Zalevsky, Zeev

    2016-09-01

    We present the first steps of a device suitable for characterization of complex 3D micro-structures. This method is based on an optical approach allowing extraction and separation of high frequency ultrasonic sound waves induced to the analyzed samples. Rapid, non-destructive characterization of 3D micro-structures are limited in terms of geometrical features and optical properties of the sample. We suggest a method which is based on temporal tracking of secondary speckle patterns generated when illuminating a sample with a laser probe while applying known periodic vibration using an ultrasound transmitter. In this paper we investigated lasers drilled through glass vias. The large aspect ratios of the vias possess a challenge for traditional microscopy techniques in analyzing depth and taper profiles of the vias. The correlation of the amplitude vibrations to the vias depths is experimentally demonstrated.

  2. Probe Techniques. Introductory Remarks

    Energy Technology Data Exchange (ETDEWEB)

    Emeleus, K. G. [School of Physics and Applied Mathematics, Queen' s University, Belfast (United Kingdom)

    1968-04-15

    In this brief introduction to the session on probes, the history of theii development is first touched on briefly. Reference is then made to the significance of the work to be described by Medicus, for conductivity and recombination calculations, and by Lam and Su, for a wide range of medium and higher pressure plasmas. Finally, a number of other probe topics are mentioned, including multiple probes; probes in electronegative plasmas; resonance probes; probes in noisy discharges; probes as oscillation detectors; use of probes where space-charge is not negligible. (author)

  3. Minimum critical crack depths in pressure vessels guidelines for nondestructive testing

    International Nuclear Information System (INIS)

    Crossley, M.R.; Townley, C.H.A.

    1983-09-01

    Estimates of the minimum critical depths which can be expected in high quality vessels designed to certain British and American Code rules are given. A simple means of allowing for fatigue crack growth in service is included. The data which are presented can be used to decide what sensitivity and what reporting levels should be employed during an ultrasonic inspection of a pressure vessel. It is emphasised that the minimum crack depths are those which would be relevant to a vessel in which the material is stressed to its maximum permitted value during operation. Stresses may, in practice, be significantly less than this. Less restrictive inspection standards may be established, if it were considered worthwhile to carry out a detailed stress analysis of the particular vessel under examination. (author)

  4. Probe-diverse ptychography

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, I., E-mail: isaac.russellpeterson@rmit.edu.au [ARC Centre of Excellence for Coherent X-ray Science, the University of Melbourne, School of Physics, Victoria 3010 (Australia); Harder, R. [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States); Robinson, I.K. [Research Complex at Harwell, Didcot, Oxfordshire OX11 0DE (United Kingdom); London Centre for Nanotechnology, University College London, London WC1H 0AH (United Kingdom)

    2016-12-15

    We propose an extension of ptychography where the target sample is scanned separately through several probes with distinct amplitude and phase profiles and a diffraction image is recorded for each probe and each sample translation. The resulting probe-diverse dataset is used to iteratively retrieve high-resolution images of the sample and all probes simultaneously. The method is shown to yield significant improvement in the reconstructed sample image compared to the image obtained using the standard single-probe ptychographic phase-retrieval scheme.

  5. Results of performance testing the Russian RPV temperature measurement probe used for annealing

    International Nuclear Information System (INIS)

    Nakos, J.T.; Selsky, S.

    1998-03-01

    This paper provides information on three (3) topics related to temperature measurements in an annealing procedure: (1) results of a series of experiments performed by CNIITMASH of the Russian consortium MOHT on their reactor pressure vessel (RPV) temperature measurement probe, (2) a discussion regarding uncertainties and errors in RPV temperature measurements, and (3) predictions from a thermal model of a spherical RPV temperature measurement probe. MOHT teamed with MPR Associates and was to perform the Annealing Demonstration Project (ADP) on behalf of the US Department of Energy, ESEERCo, EPRI, CRIEPI, Framatome, and Consumers Power Co. at the Midland plant. Experimental results show that the CNIITMASH probe errors are a maximum of about 27 C (49 F) during a 15 C/hr (27 F/hr) heat-up but only about 3 C (5.4 F) (0.6%) during the hold portion at 470 C (878 F). These errors are much smaller than those obtained from a similar series of experiments performed by Sandia National Laboratories (Sandia). The discussion about uncertainties and errors shows that results presented as a temperature difference provides a measure of the probe error. Qualitative agreement is shown between the model predictions, the experimental results of the CNIITMASH probe and the experimental results of a series of similar experiments performed by Sandia

  6. Accurate Depth of Radiofrequency-Induced Lesions in Renal Sympathetic Denervation Based on a Fine Histological Sectioning Approach in a Porcine Model.

    Science.gov (United States)

    Sakaoka, Atsushi; Terao, Hisako; Nakamura, Shintaro; Hagiwara, Hitomi; Furukawa, Toshihito; Matsumura, Kiyoshi; Sakakura, Kenichi

    2018-02-01

    Ablation lesion depth caused by radiofrequency-based renal denervation (RDN) was limited to radiofrequency-RDN cannot ablate a substantial percentage of renal sympathetic nerves. We aimed to define the true lesion depth achieved with radiofrequency-RDN using a fine sectioning method and to investigate biophysical parameters that could predict lesion depth. Radiofrequency was delivered to 87 sites in 14 renal arteries from 9 farm pigs at various ablation settings: 2, 4, 6, and 9 W for 60 seconds and 6 W for 120 seconds. Electric impedance and electrode temperature were recorded during ablation. At 7 days, 2470 histological sections were obtained from the treated arteries. Maximum lesion depth increased at 2 to 6 W, peaking at 6.53 (95% confidence interval, 4.27-8.78) mm under the 6 W/60 s condition. It was not augmented by greater power (9 W) or longer duration (120 seconds). There were statistically significant tendencies at 6 and 9 W, with higher injury scores in the media, nerves, arterioles, and fat. Maximum lesion depth was positively correlated with impedance reduction and peak electrode temperature (Pearson correlation coefficients were 0.59 and 0.53, respectively). Lesion depth was 6.5 mm for radiofrequency-RDN at 6 W/60 s. The impedance reduction and peak electrode temperature during ablation were closely associated with lesion depth. Hence, these biophysical parameters could provide prompt feedback during radiofrequency-RDN procedures in the clinical setting. © 2018 The Authors.

  7. RBS and ERDA determinations of depth distributions of high-dose carbon ions implanted in silicon for silicon-carbide synthesis study

    International Nuclear Information System (INIS)

    Intarasiri, S.; Kamwanna, T.; Hallen, A.; Yu, L.D.; Janson, M.S.; Thongleum, C.; Possnert, G.; Singkarat, S.

    2006-01-01

    For ion beam synthesis of silicon carbide (SiC), a knowledge of the depth distribution of implanted carbon ions in silicon is crucial for successful development. Based on its simplicity and availability, we selected Rutherford backscattering spectrometry (RBS) as an analysis technique for this purpose. A self-developed computer program dedicated to extract depth profiles of lighter impurities in heavier matrix is established. For control, calculated results are compared with an other ion beam analysis (IBA) technique superior for studying lighter impurity in heavier substrate i.e. elastic recoil detection analysis (ERDA). The RBS was performed with a 1.7-MV Tandetron accelerator using He 2+ as the probe ions. The ERDA was performed with a 5-MV Pelletron accelerator using I 8+ as the probe ions. This work shows that the RBS-extracted data had no significant deviations from those of ERDA and simulations by SRIM2003 and SIIMPL computer codes. We also found that annealing at temperatures as high as 1000 deg. C had quite limited effect on the redistribution of carbon in silicon

  8. Solid-state NMR paramagnetic relaxation enhancement immersion depth studies in phospholipid bilayers

    KAUST Repository

    Chu, Shidong

    2010-11-01

    A new approach for determining the membrane immersion depth of a spin-labeled probe has been developed using paramagnetic relaxation enhancement (PRE) in solid-state NMR spectroscopy. A DOXYL spin label was placed at different sites of 1-palmitoyl-2-stearoyl-sn-glycero-3-phosphocholine (PSPC) phospholipid bilayers as paramagnetic moieties and the resulting enhancements of the longitudinal relaxation (T1) times of 31P nuclei on the surface of the bilayers were measured by a standard inversion recovery pulse sequence. The 31P NMR spin-lattice relaxation times decrease steadily as the DOXYL spin label moves closer to the surface as well as the concentration of the spin-labeled lipids increase. The enhanced relaxation vs. the position and concentration of spin-labels indicate that PRE induced by the DOXYL spin label are significant to determine longer distances over the whole range of the membrane depths. When these data were combined with estimated correlation times τc, the r-6-weighted, time-averaged distances between the spin-labels and the 31P nuclei on the membrane surface were estimated. The application of using this solid-state NMR PRE approach coupled with site-directed spin labeling (SDSL) may be a powerful method for measuring membrane protein immersion depth. © 2010 Elsevier Inc. All rights reserved.

  9. CFHT's SkyProbe: True Atmospheric Attenuation Measurement in the Telescope Field

    Science.gov (United States)

    Cuillandre, J.-C.; Magnier, E. A.; Isani, S.; Sabin, D.; Knight, W.; Kras, S.; Lai, K.

    Developed at the Canada France Hawaii Telescope (CFHT), SkyProbe is a system that allows the direct measurement of the true attenuation by clouds. This measurement is performed approximately once per min, directly on the field viewed by the telescope. It has been possible to make this system relatively inexpensively due to low cost CCD cameras available on the amateur market. A crucial addition to this hardware is the recent availability of a full-sky photometry catalog at the appropriate depth: the Tycho catalog from the Hipparcos mission. A very important element in the SkyProbe data set creation is the automatic data analysis pipeline, Elixir, developed at CFHT for the improved operation of the CFHT wide-field imagers CFH12K and MegaCam. SkyProbe's FITS images are processed in real time, and the pipeline output (a zero point attenuation) provides the current sky transmission to the observers and aids immediate decision making. These measurements are also attached to the archived data, adding a key tool for future use by other astronomers. Specific features of the detector, such as intra pixel quantum efficiency variations, must be taken into consideration since the data are strongly undersampled.

  10. Design and array signal suggestion of array type pulsed eddy current probe for health monitoring of metal tubes

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Young Kil [Dept. of Electrical Engineering, Kunsan National University, Kunsan (Korea, Republic of)

    2015-10-15

    An array type probe for monitoring metal tubes is proposed in this paper which utilizes peak value and peak time of a pulsed eddy current(PEC) signal. The probe consists of an array of encircling coils along a tube and the outside of coils is shielded by ferrite to prevent source magnetic fields from directly affecting sensor signals since it is the magnetic fields produced by eddy currents that reflect the condition of metal tubes. The positions of both exciter and sensor coils are consecutively moved automatically so that manual scanning is not necessary. At one position of send-receive coils, peak value and peak time are extracted from a sensor PEC signal and these data are accumulated for all positions to form an array type peak value signal and an array type peak time signal. Numerical simulation was performed using the backward difference method in time and the finite element method for spatial analysis. Simulation results showed that peak value increases and the peak appears earlier as the defect depth or length increases. The proposed array signals are shown to be excellent in reflecting the defect location as well as variations of defect depth and length within the array probe.

  11. Atom-probe field-ion-microscope mass spectrometer

    International Nuclear Information System (INIS)

    Nishikawa, Osamu

    1983-01-01

    The titled analyzer, called simply atom-probe, has been developed by combining a field ion microscope (FIM) and a mass spectrometer, and is divided into the time-of-flight type, magnetic sector type, and quadrupole type depending on the types of mass spectrometers. In this paper, the author first describes on the principle and construction of a high resolution, time-of-flight atom-probe developed and fabricated in his laboratory. The feature of the atom-probe lies in the analysis of atoms and molecules in hyper-fine structure region one by one utilizing the high resolution of FIM. It also has the advantages of directly determining the composition by a ratio of the numbers of respective ions because of a constant detection sensitivity regardless of mass numbers, of the resolution as high as single atom layer in depth direction, and of detecting the positional relationship among detected ions by the order of detection in a sample. To determine the composition in a hyperfine structure region, the limited small number of atoms and molecules in the region must be identified distinctly one by one. In the analyzed result of Ni-silicide formed by heating Si evaporated on a Ni tip at 1000 K for 5 minutes, each isotope was not only clearly separated, but also their abundance ratio was very close to the natural abundance ratio. The second half of the paper reports on the analysis of TiC promising for a cold cathode material, adsorption of CO and alcohol, and the composition and structure of silicides, as a few application examples. (Wakatsuki, Y.)

  12. Electrical resistivity probes

    Science.gov (United States)

    Lee, Ki Ha; Becker, Alex; Faybishenko, Boris A.; Solbau, Ray D.

    2003-10-21

    A miniaturized electrical resistivity (ER) probe based on a known current-voltage (I-V) electrode structure, the Wenner array, is designed for local (point) measurement. A pair of voltage measuring electrodes are positioned between a pair of current carrying electrodes. The electrodes are typically about 1 cm long, separated by 1 cm, so the probe is only about 1 inch long. The electrodes are mounted to a rigid tube with electrical wires in the tube and a sand bag may be placed around the electrodes to protect the electrodes. The probes can be positioned in a borehole or on the surface. The electrodes make contact with the surrounding medium. In a dual mode system, individual probes of a plurality of spaced probes can be used to measure local resistance, i.e. point measurements, but the system can select different probes to make interval measurements between probes and between boreholes.

  13. Interacting Effects Induced by Two Neighboring Pits Considering Relative Position Parameters and Pit Depth

    Directory of Open Access Journals (Sweden)

    Yongfang Huang

    2017-04-01

    Full Text Available For pre-corroded aluminum alloy 7075-T6, the interacting effects of two neighboring pits on the stress concentration are comprehensively analyzed by considering various relative position parameters (inclination angle θ and dimensionless spacing parameter λ and pit depth (d with the finite element method. According to the severity of the stress concentration, the critical corrosion regions, bearing high susceptibility to fatigue damage, are determined for intersecting and adjacent pits, respectively. A straightforward approach is accordingly proposed to conservatively estimate the combined stress concentration factor induced by two neighboring pits, and a concrete application example is presented. It is found that for intersecting pits, the normalized stress concentration factor Ktnor increases with the increase of θ and λ and always reaches its maximum at θ = 90°, yet for adjacent pits, Ktnor decreases with the increase of λ and the maximum value appears at a slight asymmetric location. The simulations reveal that Ktnor follows a linear and an exponential relationship with the dimensionless depth parameter Rd for intersecting and adjacent cases, respectively.

  14. Monte Carlo Simulation of Quantitative Electron Probe Microanalysis of the PWR Spent Fuel with a Pt Coating

    International Nuclear Information System (INIS)

    Kwon, Hyoung Mun; Lee, Hyung Kwon; Son, Young Zoon; Chun, Yong Bum

    2012-01-01

    The PWR spent fuel sample should be coated with conducting material in order to provide a path for electrons and to prevent charging. Generally, the ZAF method has been used for quantitative electron probe microanalysis of conducting samples. However, the coated samples are not applicable for the ZAF method. Probe current, primary electron energy and x-ray produced by the primary beam are attenuated within the coating films. The electron and X-ray depth distributions for a quantitative electron probe micro analysis were simulated by the CASINO Monte Carlo program [2] to evaluate the x-ray attenuation within the Pt coating films. The target samples are the PWR spent fuels with 50 GWd/tU of burnup , 6 years of cooling time and a Pt coating film (3, 5, 7, 10 and 15 nm thickness)

  15. Monte Carlo Simulation of Quantitative Electron Probe Microanalysis of the PWR Spent Fuel with a Pt Coating

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyoung Mun; Lee, Hyung Kwon; Son, Young Zoon; Chun, Yong Bum [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    The PWR spent fuel sample should be coated with conducting material in order to provide a path for electrons and to prevent charging. Generally, the ZAF method has been used for quantitative electron probe microanalysis of conducting samples. However, the coated samples are not applicable for the ZAF method. Probe current, primary electron energy and x-ray produced by the primary beam are attenuated within the coating films. The electron and X-ray depth distributions for a quantitative electron probe micro analysis were simulated by the CASINO Monte Carlo program [2] to evaluate the x-ray attenuation within the Pt coating films. The target samples are the PWR spent fuels with 50 GWd/tU of burnup , 6 years of cooling time and a Pt coating film (3, 5, 7, 10 and 15 nm thickness)

  16. Constraints on pulsar masses from the maximum observed glitch

    Science.gov (United States)

    Pizzochero, P. M.; Antonelli, M.; Haskell, B.; Seveso, S.

    2017-07-01

    Neutron stars are unique cosmic laboratories in which fundamental physics can be probed in extreme conditions not accessible to terrestrial experiments. In particular, the precise timing of rotating magnetized neutron stars (pulsars) reveals sudden jumps in rotational frequency in these otherwise steadily spinning-down objects. These 'glitches' are thought to be due to the presence of a superfluid component in the star, and offer a unique glimpse into the interior physics of neutron stars. In this paper we propose an innovative method to constrain the mass of glitching pulsars, using observations of the maximum glitch observed in a star, together with state-of-the-art microphysical models of the pinning interaction between superfluid vortices and ions in the crust. We study the properties of a physically consistent angular momentum reservoir of pinned vorticity, and we find a general inverse relation between the size of the maximum glitch and the pulsar mass. We are then able to estimate the mass of all the observed glitchers that have displayed at least two large events. Our procedure will allow current and future observations of glitching pulsars to constrain not only the physics of glitch models but also the superfluid properties of dense hadronic matter in neutron star interiors.

  17. Design, validation and annotation of transcriptome-wide oligonucleotide probes for the oligochaete annelid Eisenia fetida.

    Directory of Open Access Journals (Sweden)

    Ping Gong

    Full Text Available High density oligonucleotide probe arrays have increasingly become an important tool in genomics studies. In organisms with incomplete genome sequence, one strategy for oligo probe design is to reduce the number of unique probes that target every non-redundant transcript through bioinformatic analysis and experimental testing. Here we adopted this strategy in making oligo probes for the earthworm Eisenia fetida, a species for which we have sequenced transcriptome-scale expressed sequence tags (ESTs. Our objectives were to identify unique transcripts as targets, to select an optimal and non-redundant oligo probe for each of these target ESTs, and to annotate the selected target sequences. We developed a streamlined and easy-to-follow approach to the design, validation and annotation of species-specific array probes. Four 244K-formatted oligo arrays were designed using eArray and were hybridized to a pooled E. fetida cRNA sample. We identified 63,541 probes with unsaturated signal intensities consistently above the background level. Target transcripts of these probes were annotated using several sequence alignment algorithms. Significant hits were obtained for 37,439 (59% probed targets. We validated and made publicly available 63.5K oligo probes so the earthworm research community can use them to pursue ecological, toxicological, and other functional genomics questions. Our approach is efficient, cost-effective and robust because it (1 does not require a major genomics core facility; (2 allows new probes to be easily added and old probes modified or eliminated when new sequence information becomes available, (3 is not bioinformatics-intensive upfront but does provide opportunities for more in-depth annotation of biological functions for target genes; and (4 if desired, EST orthologs to the UniGene clusters of a reference genome can be identified and selected in order to improve the target gene specificity of designed probes. This approach is

  18. Fluorescent eosin probe in investigations of structural changes in glycated proteins

    Science.gov (United States)

    Pravdin, A. B.; Kochubey, V. I.; Mel'Nikov, A. G.

    2010-08-01

    The possibility of using the luminescent-kinetic probe method to investigate structural changes in bovine serum albumin (BSA) upon nonenzymatic thermal glycation is studied. An increase in the glycation time lead to a decrease in the intensity of the probe (eosin) fluorescence and to a long-wavelength shift of its maximum, as well as to an increase in the eosin phosphorescence intensity, which indicates that eosin binds to hydrophobic regions of protein at any times of incubation of BSA with glucose. From a decrease in the rate constant of the triplet-triplet energy transfer between the donor (eosin) and acceptor (anthracene) bound to proteins, it is found that the changes observed in the spectral characteristics of eosin are caused by structural changes in albumin globules as a result of glycosylation.

  19. Assessment of an ultrasonic sensor and a capacitance probe for measurement of two-phase mixture level

    International Nuclear Information System (INIS)

    Kim, Chang Hyun; Lee, Dong Won; No, Hee Cheon

    2004-01-01

    We perform a comparison of two-phase mixture levels measured by an ultrasonic sensor and a two-wire type capacitance probe with visual data under the same experimental conditions. A series of experiments are performed with various combinations of airflow and initial water level using a test vessel with a height of 2m and an inner diameter of 0.3 m under atmospheric pressure and room temperature. The ultrasonic sensor measures the two-phase mixture level with a maximum error of 1.77% with respect to the visual data. The capacitance probe severely under-predicts the level data in the high void fraction region. The cause of the error is identified as the change of the dielectric constant as the void fraction changes when the probe is applied to the measurement of the two-phase mixture levels. A correction method for the capacitance probe is proposed by correcting the change of dielectric constant of the two-phase mixture. The correction method for the capacitance probe produces a r.m.s. error of 5.4%. (author)

  20. Global view of F-region electron density and temperature at solar maximum

    International Nuclear Information System (INIS)

    Brace, L.H.; Theis, R.F.; Hoegy, W.R.

    1982-01-01

    Dynamics Explorer-2 is permitting the first measurements of the global structure of the F-regions at very high levels of solar activity (S>200). Selected full orbits of Langmuir probe measurements of electron temperature, T/sub e/, and density, N/sub e/, are shown to illustrate this global structure and some of the ionospheric features that are the topic of other papers in this issue. The ionospheric thermal structure is of particular interest because T/sub e/ is a sensitive indicator of the coupling of magnetospheric energy into the upper atmosphere. A comparison of these heating effects with those observed at solar minimum shows that the magnetospheric sources are more important at solar maximum, as might have been expected. Heating at the cusp, the auroral oval and the plasma-pause is generally both greater and more variable. Electron cooling rate calculations employing low latitude measurements indicate that solar extreme ultraviolet heating of the F region at solar maximum is enhanced by a factor that is greater than the increase in solar flux. Some of this enhanced electron heating arises from the increase in electron heating efficiency at the higher N/sub e/ of solar maximum, but this appears insufficient to completely resolve the discrepancy

  1. An Exploration of the Needling Depth in Acupuncture: The Safe Needling Depth and the Needling Depth of Clinical Efficacy

    Directory of Open Access Journals (Sweden)

    Jaung-Geng Lin

    2013-01-01

    Full Text Available Objective. To explore the existing scientific information regarding safe needling depth of acupuncture points and the needling depth of clinical efficacy. Methods. We searched the PubMed, EMBASE, Cochrane, Allied and Complementary Medicine (AMED, The National Center for Complementary and Alternative Medicine (NCCAM, and China National Knowledge Infrastructure (CNKI databases to identify relevant monographs and related references from 1991 to 2013. Chinese journals and theses/dissertations were hand searched. Results. 47 studies were recruited and divided into 6 groups by measuring tools, that is, MRI, in vivo evaluation, CT, ultrasound, dissected specimen of cadavers, and another group with clinical efficacy. Each research was analyzed for study design, definition of safe depth, and factors that would affect the measured depths. Depths of clinical efficacy were discussed from the perspective of de-qi and other clinical observations. Conclusions. Great inconsistency in depth of each point measured from different subject groups and tools exists. The definition of safe depth should be established through standardization. There is also lack of researches to compare the clinical efficacy. A well-designed clinical trial selecting proper measuring tools to decide the actual and advisable needling depth for each point, to avoid adverse effects or complications and promote optimal clinical efficacy, is a top priority.

  2. Estimation of calcaneal loading during standing from human footprint depths using 3D scanner

    Science.gov (United States)

    Wibowo, Dwi Basuki; Haryadi, Gunawan Dwi; Widodo, Achmad; Rahayu, Sri Puji

    2017-01-01

    This research studies the relationship between footprint depths and load in the calcaneal area when human standing in an upright posture. Footprint depths are deformation in the calcaneal area obtained from the z-value extraction of the Boolean operation acquired from unloaded foot scanning using 3D scanner and loaded foot using foot plantar scanner. To compare peak loads estimated from footprint depth maximum, force sensing resistor (FSR) sensor is attached over the shoe insole with zero heel height in the calcaneal area. Twenty participants were selected from students of Mechanical Engineering Department Diponegoro University with the average the age and the body weight 19.5 years and 55.27 kg respectively. Results that were relatively accurate was found on the calcaneal loading estimation by footprint depth is presented by curve and data distribution which are in good agreement with the result of the measurement. A significant difference in estimating calcaneal loading is mainly caused by plantar foot position of research subjects which is not perpendicular to foot ankle and hallux. In addition, plantar foot position which bends to front/back/side affects the result of footprint depths.

  3. High spatial resolution Kelvin probe force microscopy with coaxial probes

    International Nuclear Information System (INIS)

    Brown, Keith A; Westervelt, Robert M; Satzinger, Kevin J

    2012-01-01

    Kelvin probe force microscopy (KPFM) is a widely used technique to measure the local contact potential difference (CPD) between an AFM probe and the sample surface via the electrostatic force. The spatial resolution of KPFM is intrinsically limited by the long range of the electrostatic interaction, which includes contributions from the macroscopic cantilever and the conical tip. Here, we present coaxial AFM probes in which the cantilever and cone are shielded by a conducting shell, confining the tip–sample electrostatic interaction to a small region near the end of the tip. We have developed a technique to measure the true CPD despite the presence of the shell electrode. We find that the behavior of these probes agrees with an electrostatic model of the force, and we observe a factor of five improvement in spatial resolution relative to unshielded probes. Our discussion centers on KPFM, but the field confinement offered by these probes may improve any variant of electrostatic force microscopy. (paper)

  4. Evaluation of a three-dimensional ultrasound localisation system incorporating probe pressure correction for use in partial breast irradiation.

    Science.gov (United States)

    Harris, E J; Symonds-Taylor, R; Treece, G M; Gee, A H; Prager, R W; Brabants, P; Evans, P M

    2009-10-01

    This work evaluates a three-dimensional (3D) freehand ultrasound-based localisation system with new probe pressure correction for use in partial breast irradiation. Accuracy and precision of absolute position measurement was measured as a function of imaging depth (ID), object depth, scanning direction and time using a water phantom containing crossed wires. To quantify the improvement in accuracy due to pressure correction, 3D scans of a breast phantom containing ball bearings were obtained with and without pressure. Ball bearing displacements were then measured with and without pressure correction. Using a single scan direction (for all imaging depths), the mean error was <1.3 mm, with the exception of the wires at 68.5 mm imaged with an ID of 85 mm, which gave a mean error of -2.3 mm. Precision was greater than 1 mm for any single scan direction. For multiple scan directions, precision was within 1.7 mm. Probe pressure corrections of between 0 mm and 2.2 mm have been observed for pressure displacements of 1.1 mm to 4.2 mm. Overall, anteroposterior position measurement accuracy increased from 2.2 mm to 1.6 mm and to 1.4 mm for the two opposing scanning directions. Precision is comparable to that reported for other commercially available ultrasound localisation systems, provided that 3D image acquisition is performed in the same scan direction. The existing temporal calibration is imperfect and a "per installation" calibration would further improve the accuracy and precision. Probe pressure correction was shown to improve the accuracy and will be useful for the localisation of the excision cavity in partial breast radiotherapy.

  5. A multi-step electrochemical etching process for a three-dimensional micro probe array

    International Nuclear Information System (INIS)

    Kim, Yoonji; Youn, Sechan; Cho, Young-Ho; Park, HoJoon; Chang, Byeung Gyu; Oh, Yong Soo

    2011-01-01

    We present a simple, fast, and cost-effective process for three-dimensional (3D) micro probe array fabrication using multi-step electrochemical metal foil etching. Compared to the previous electroplating (add-on) process, the present electrochemical (subtractive) process results in well-controlled material properties of the metallic microstructures. In the experimental study, we describe the single-step and multi-step electrochemical aluminum foil etching processes. In the single-step process, the depth etch rate and the bias etch rate of an aluminum foil have been measured as 1.50 ± 0.10 and 0.77 ± 0.03 µm min −1 , respectively. On the basis of the single-step process results, we have designed and performed the two-step electrochemical etching process for the 3D micro probe array fabrication. The fabricated 3D micro probe array shows the vertical and lateral fabrication errors of 15.5 ± 5.8% and 3.3 ± 0.9%, respectively, with the surface roughness of 37.4 ± 9.6 nm. The contact force and the contact resistance of the 3D micro probe array have been measured to be 24.30 ± 0.98 mN and 2.27 ± 0.11 Ω, respectively, for an overdrive of 49.12 ± 1.25 µm.

  6. Advances in Probes and Methods for Clinical EPR Oximetry

    Science.gov (United States)

    Hou, Huagang; Khan, Nadeem; Jarvis, Lesley A.; Chen, Eunice Y.; Williams, Benjamin B.; Kuppusamy, Periannan

    2015-01-01

    EPR oximetry, which enables reliable, accurate, and repeated measurements of the partial pressure of oxygen in tissues, provides a unique opportunity to investigate the role of oxygen in the pathogenesis and treatment of several diseases including cancer, stroke, and heart failure. Building on significant advances in the in vivo application of EPR oximetry for small animal models of disease, we are developing suitable probes and instrumentation required for use in human subjects. Our laboratory has established the feasibility of clinical EPR oximetry in cancer patients using India ink, the only material presently approved for clinical use. We now are developing the next generation of probes, which are both superior in terms of oxygen sensitivity and biocompatibility including an excellent safety profile for use in humans. Further advances include the development of implantable oxygen sensors linked to an external coupling loop for measurements of deep-tissue oxygenations at any depth, overcoming the current limitation of 10 mm. This paper presents an overview of recent developments in our ability to make meaningful measurements of oxygen partial pressures in human subjects under clinical settings. PMID:24729217

  7. The endo-rectal probe prototype for the TOPEM project

    Energy Technology Data Exchange (ETDEWEB)

    Musico, Paolo, E-mail: Paolo.Musico@ge.infn.it

    2016-07-11

    The TOPEM project was funded by INFN with the aim of studying the design of a TOF-PET system dedicated to prostate imaging. During last year a big effort was put into building the prototype of the endo-rectal probe from all point of view: mechanical, thermal, electrical. A dedicated integrated circuit was adopted to have the minimum dimensions: the TOFPET ASIC. The system is composed by a LYSO pixellated crystal which is seen by a 128 SiPM matrix on both surfaces: this permits Depth Of Interaction (DOI) measurement. The 4 needed ASICs are handled by a FPGA board which transmits the acquired data over an UDP connection. The external container was made using 3-D printing technology: internal channels on the external surface permit the flowing of controlled temperature (≈35 °C) water. Electronic components power is dissipated using an internal air flow kept at lower temperature (≈20 °C). The probe is MR compatible: a dedicated small antenna can be accommodated in the container. This will permit simultaneous imaging in MRI and PET systems.

  8. Defects in heavily phosphorus-doped Si epitaxial films probed by monoenergetic positron beams

    International Nuclear Information System (INIS)

    Uedono, Akira; Tanigawa, Shoichiro; Suzuki, Ryoichi; Ohgaki, Hideaki; Mikado, Tomohisa.

    1994-01-01

    Vacancy-type defects in heavily phosphorus-doped Si epitaxial films were probed by monoenergetic positron beams. Doppler broadening profiles of the annihilation radiation and lifetime spectra of positrons were measured for the epitaxial films grown on the Si substrates by plasma chemical vapor deposition. For the as-deposited film, divacancy-phosphorus complexes were found with high concentration. After 600degC annealing, vacancy clusters were formed near the Si/Si interface, while no drastic change in the depth distribution of the divacancy-phosphorus complexes was observed. By 900degC annealing, the vacancy clusters were annealed out; however, the average number of phosphorus atoms coupled with divacancies increased. The relationship between the vacancy-type defects probed by the positron annihilation technique and the carrier concentration was confirmed. (author)

  9. Defects in heavily phosphorus-doped Si epitaxial films probed by monoenergetic positron beams

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Suzuki, Ryoichi; Ohgaki, Hideaki; Mikado, Tomohisa

    1994-11-01

    Vacancy-type defects in heavily phosphorus-doped Si epitaxial films were probed by monoenergetic positron beams. Doppler broadening profiles of the annihilation radiation and lifetime spectra of positrons were measured for the epitaxial films grown on the Si substrates by plasma chemical vapor deposition. For the as-deposited film, divacancy-phosphorus complexes were found with high concentration. After 600degC annealing, vacancy clusters were formed near the Si/Si interface, while no drastic change in the depth distribution of the divacancy-phosphorus complexes was observed. By 900degC annealing, the vacancy clusters were annealed out; however, the average number of phosphorus atoms coupled with divacancies increased. The relationship between the vacancy-type defects probed by the positron annihilation technique and the carrier concentration was confirmed. (author).

  10. Approximate maximum parsimony and ancestral maximum likelihood.

    Science.gov (United States)

    Alon, Noga; Chor, Benny; Pardi, Fabio; Rapoport, Anat

    2010-01-01

    We explore the maximum parsimony (MP) and ancestral maximum likelihood (AML) criteria in phylogenetic tree reconstruction. Both problems are NP-hard, so we seek approximate solutions. We formulate the two problems as Steiner tree problems under appropriate distances. The gist of our approach is the succinct characterization of Steiner trees for a small number of leaves for the two distances. This enables the use of known Steiner tree approximation algorithms. The approach leads to a 16/9 approximation ratio for AML and asymptotically to a 1.55 approximation ratio for MP.

  11. An image fiber based fluorescent probe with associated signal processing scheme for biomedical diagnostics

    International Nuclear Information System (INIS)

    Vaishakh, M; Murukeshan, V M; Seah, L K

    2008-01-01

    A dual-modality image fiber based fluorescent probe that can be used for depth sensitive imaging and suppression of fluorescent emissions with nanosecond lifetime difference is proposed and illustrated in this paper. The system can give high optical sectioning and employs an algorithm for obtaining phase sensitive images. The system can find main application in in vivo biomedical diagnostics for detecting biochemical changes for distinguishing malignant tissue from healthy tissue

  12. Probes for the development of medium deep geothermal energy; Sonden zur Erschliessung der mitteltiefen Geothermie

    Energy Technology Data Exchange (ETDEWEB)

    Stuckmann, Uwe; Gottschalk, Daniel [REHAU AG und Co., Rehau (Germany)

    2011-10-24

    Compared to the near-surface geothermal energy, higher temperatures can be developed in the medium-depth geothermal energy (400 to 1,000 meters). Thus, the efficiency of geothermal power plants can be increased. The significantly higher yield performance and extraction performance are opposite to the higher costs of installation. At high thermal gradients of the surface one may completely dispense with the heat pump and directly heat. Geothermal probes at the current state of the art are reaching the limits of its applicability. Only newly developed geothermal probes offer a pressure resistance and temperature resistance in order to exploit these deeper regions. Such projects will be accompanied by the mining authority according to the power of approval. Extensive financial supports are available with the market incentive program of the Federal Government. Thus, the use of geothermal probes is possible in deeper regions. The feasibility and cost of future projects will be affected positively.

  13. Weighted halfspace depth

    Czech Academy of Sciences Publication Activity Database

    Kotík, Lukáš; Hlubinka, D.; Vencálek, O.

    Vol. 46, č. 1 (2010), s. 125-148 ISSN 0023-5954 Institutional research plan: CEZ:AV0Z10750506 Keywords : data depth * nonparametric multivariate analysis * strong consistency of depth * mixture of distributions Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.461, year: 2010 http://library.utia.cas.cz/separaty/2010/SI/kotik-weighted halfspace depth.pdf

  14. Minimum decoding trellis length and truncation depth of wrap-around Viterbi algorithm for TBCC in mobile WiMAX

    Directory of Open Access Journals (Sweden)

    Liu Yu-Sun

    2011-01-01

    Full Text Available Abstract The performance of the wrap-around Viterbi decoding algorithm with finite truncation depth and fixed decoding trellis length is investigated for tail-biting convolutional codes in the mobile WiMAX standard. Upper bounds on the error probabilities induced by finite truncation depth and the uncertainty of the initial state are derived for the AWGN channel. The truncation depth and the decoding trellis length that yield negligible performance loss are obtained for all transmission rates over the Rayleigh channel using computer simulations. The results show that the circular decoding algorithm with an appropriately chosen truncation depth and a decoding trellis just a fraction longer than the original received code words can achieve almost the same performance as the optimal maximum likelihood decoding algorithm in mobile WiMAX. A rule of thumb for the values of the truncation depth and the trellis tail length is also proposed.

  15. DNA probes

    International Nuclear Information System (INIS)

    Castelino, J.

    1992-01-01

    The creation of DNA probes for detection of specific nucleotide segments differs from ligand detection in that it is a chemical rather than an immunological reaction. Complementary DNA or RNA is used in place of the antibody and is labelled with 32 P. So far, DNA probes have been successfully employed in the diagnosis of inherited disorders, infectious diseases, and for identification of human oncogenes. The latest approach to the diagnosis of communicable and parasitic infections is based on the use of deoxyribonucleic acid (DNA) probes. The genetic information of all cells is encoded by DNA and DNA probe approach to identification of pathogens is unique because the focus of the method is the nucleic acid content of the organism rather than the products that the nucleic acid encodes. Since every properly classified species has some unique nucleotide sequences that distinguish it from every other species, each organism's genetic composition is in essence a finger print that can be used for its identification. In addition to this specificity, DNA probes offer other advantages in that pathogens may be identified directly in clinical specimens

  16. Counting probe

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki; Yuasa, Kazuhiro; Hayashi, Tomoaki

    1976-01-01

    Electron counting method has been devised and experimented for the purpose of measuring electron temperature and density, the most fundamental quantities to represent plasma conditions. Electron counting is a method to count the electrons in plasma directly by equipping a probe with the secondary electron multiplier. It has three advantages of adjustable sensitivity, high sensitivity of the secondary electron multiplier, and directional property. Sensitivity adjustment is performed by changing the size of collecting hole (pin hole) on the incident front of the multiplier. The probe is usable as a direct reading thermometer of electron temperature because it requires to collect very small amount of electrons, thus it doesn't disturb the surrounding plasma, and the narrow sweep width of the probe voltage is enough. Therefore it can measure anisotropy more sensitively than a Langmuir probe, and it can be used for very low density plasma. Though many problems remain on anisotropy, computer simulation has been carried out. Also it is planned to provide a Helmholtz coil in the vacuum chamber to eliminate the effect of earth magnetic field. In practical experiments, the measurement with a Langmuir probe and an emission probe mounted to the movable structure, the comparison with the results obtained in reverse magnetic field by using a Helmholtz coil, and the measurement of ionic sound wave are scheduled. (Wakatsuki, Y.)

  17. Minimum disturbance rewards with maximum possible classical correlations

    Energy Technology Data Exchange (ETDEWEB)

    Pande, Varad R., E-mail: varad_pande@yahoo.in [Department of Physics, Indian Institute of Science Education and Research Pune, 411008 (India); Shaji, Anil [School of Physics, Indian Institute of Science Education and Research Thiruvananthapuram, 695016 (India)

    2017-07-12

    Weak measurements done on a subsystem of a bipartite system having both classical and nonClassical correlations between its components can potentially reveal information about the other subsystem with minimal disturbance to the overall state. We use weak quantum discord and the fidelity between the initial bipartite state and the state after measurement to construct a cost function that accounts for both the amount of information revealed about the other system as well as the disturbance to the overall state. We investigate the behaviour of the cost function for families of two qubit states and show that there is an optimal choice that can be made for the strength of the weak measurement. - Highlights: • Weak measurements done on one part of a bipartite system with controlled strength. • Weak quantum discord & fidelity used to quantify all correlations and disturbance. • Cost function to probe the tradeoff between extracted correlations and disturbance. • Optimal measurement strength for maximum extraction of classical correlations.

  18. Characterization of power induced heating and damage in fiber optic probes for near-field scanning optical microscopy

    Science.gov (United States)

    Dickenson, Nicholas E.; Erickson, Elizabeth S.; Mooren, Olivia L.; Dunn, Robert C.

    2007-05-01

    Tip-induced sample heating in near-field scanning optical microscopy (NSOM) is studied for fiber optic probes fabricated using the chemical etching technique. To characterize sample heating from etched NSOM probes, the spectra of a thermochromic polymer sample are measured as a function of probe output power, as was previously reported for pulled NSOM probes. The results reveal that sample heating increases rapidly to ˜55-60°C as output powers reach ˜50nW. At higher output powers, the sample heating remains approximately constant up to the maximum power studied of ˜450nW. The sample heating profiles measured for etched NSOM probes are consistent with those previously measured for NSOM probes fabricated using the pulling method. At high powers, both pulled and etched NSOM probes fail as the aluminum coating is damaged. For probes fabricated in our laboratory we find failure occurring at input powers of 3.4±1.7 and 20.7±6.9mW for pulled and etched probes, respectively. The larger half-cone angle for etched probes (˜15° for etched and ˜6° for pulled probes) enables more light delivery and also apparently leads to a different failure mechanism. For pulled NSOM probes, high resolution images of NSOM probes as power is increased reveal the development of stress fractures in the coating at a taper diameter of ˜6μm. These stress fractures, arising from the differential heating expansion of the dielectric and the metal coating, eventually lead to coating removal and probe failure. For etched tips, the absence of clear stress fractures and the pooled morphology of the damaged aluminum coating following failure suggest that thermal damage may cause coating failure, although other mechanisms cannot be ruled out.

  19. Mobile probes

    DEFF Research Database (Denmark)

    Ørngreen, Rikke; Jørgensen, Anna Neustrup; Noesgaard, Signe Schack

    2016-01-01

    A project investigating the effectiveness of a collection of online resources for teachers' professional development used mobile probes as a data collection method. Teachers received questions and tasks on their mobile in a dialogic manner while in their everyday context as opposed...... to in an interview. This method provided valuable insight into the contextual use, i.e. how did the online resource transfer to the work practice. However, the research team also found that mobile probes may provide the scaffolding necessary for individual and peer learning at a very local (intra-school) community...... level. This paper is an initial investigation of how the mobile probes process proved to engage teachers in their efforts to improve teaching. It also highlights some of the barriers emerging when applying mobile probes as a scaffold for learning....

  20. Effect of secondary structure on single nucleotide polymorphism detection with a porous microarray matrix; implications for probe selection

    NARCIS (Netherlands)

    Anthony, R. M.; Schuitema, A. R. J.; Chan, A. B.; Boender, P. J.; Klatser, P. R.; Oskam, L.

    2003-01-01

    Oligonucleotide arrays capable of detecting single nucleotide polymorphisms (SNPs) from amplified nucleic acid have many applications. The expected SNP is usually placed approximately in the center of the probe to ensure the maximum shift in Tm between complementary and SNP sequences. Unfortunately,

  1. Development of surgical gamma probes with TlBr semiconductors and CsI(Tl) scintillators crystals

    International Nuclear Information System (INIS)

    Costa, Fabio Eduardo da

    2006-01-01

    Radio guided surgery, using probes with radiation detectors, has been prominence in the medical area in the last decade. This technique consists in injecting a radioactive substance to concentrate in tumour and assist the localization during the surgical procedure. The radio guided surgeries allowing the identification of lymph node has revolutioned the behavior of tumour in initial stadium when are being spread by lymphatic way. The conditions imposed to the surgery due the proximity between some lymph nodes, demands of the probes, a small diameters and capacity of individual identification of these lymph nodes radiolabelled by a specific tracer. The international market supplies these probes with CdTe semiconductors and scintillators, but there is some time lack a promptly technical assistance in the Brazilian market. This work developed probes with national technology, using CsI(Tl) scintillators crystals and, in substitution to CdTe crystals semiconductors, the TlBr crystal, that is a new semiconductor detector in a world-wide development, with advantages in relation to the CdTe. Both crystals have been grown in IPEN. All the necessary electronics, specially, the preamplifier, that was also a restrictive factor for development of these types of probe in the country, have been developed with components found in the national market. Systematic measures of spatial resolution, spatial selectivity, maximum sensitivity and quality of the shielding have been carried the probes development. The results have shown that the probes, one with the CsI(Tl) crystal and another with TlBr semiconductor presented the requested performance in the international literature for radio guided probes. (author)

  2. Depth of magnetic basement in Iran based on fractal spectral analysis of aeromagnetic data

    Science.gov (United States)

    Teknik, Vahid; Ghods, Abdolreza

    2017-06-01

    To estimate the shape of sedimentary basins, a critical parameter in hydrocarbon exploration, we calculated the depth of magnetic basement by applying a fractal spectral method to the aeromagnetic map of Iran. The depth of magnetic basement is a close proxy for the shape of sedimentary basins provided that igneous basement is strongly magnetized relative to the overlying sediments and there is no interbedding magnetic layer in the sediments. The shape of the power spectrum of magnetic anomalies is sensitive to the depth of magnetic basement, the thickness of the magnetic layer, the fractal parameter of magnetization and the size of the window used for the calculation of the power spectrum. Using a suite of synthetic tests, we have shown that the estimation of the depth of magnetic basement of up to 20 km is not very sensitive to the often unknown fractal parameter and thus the spectral method is a reliable tool to calculate the depth of magnetic basement. The depth of magnetic basement is in the range of 7-16 km in the Zagros, east Alborz, Tabas, Jazmurian and Makran regions, showing a close correlation with depths estimated from the maximum thickness of stratigraphic columns. We have also found new sedimentary basins in Bostan Abad, Bijar and south of Orumiyeh Lake. The significant depth of the magnetic basement in the Makran, Jazmurain depression, southeast Caspian Sea, Tabas, Great Kavir, south of Orumiyeh Lake, Bostan Abad and Bijar sedimentary basins makes them future prospects for hydrocarbon explorations. The depth of magnetic basement is strongly reduced over the Neyriz and Kermanshah Ophiolites, but it does not show any meaningful correlation with other outcrops of ophiolitic rocks in Iran.

  3. Vortex imaging in superconducting films by scanning Hall probe microscopy

    International Nuclear Information System (INIS)

    Oral, A.; Bending, S.J.; Humphreys, R.G.

    1996-01-01

    The authors have used a low noise Scanning Hall Probe Microscope (SHPM) to study vortex structures in superconducting films. The microscope has high magnetic field (∼2.9 x 10 -8 T/√Hz at 77K) and spatial resolution, ∼0.85 μm. Magnetic field profiles of single vortices in High T c YBa 2 Cu 3 O 7-δ thin films have been successfully measured and the microscopic penetration depth of the superconductor has been extracted as a function of temperature. Flux penetration into the superconductor has been imaged in real time (∼8s/frame)

  4. An investigation into the depth of penetration of low level laser therapy through the equine tendon in vivo

    Directory of Open Access Journals (Sweden)

    Ryan Teresa

    2007-05-01

    Full Text Available Abstract Low level laser therapy (LLLT is frequently used in the treatment of wounds, soft tissue injury and in pain management. The exact penetration depth of LLLT in human tissue remains unspecified. Similar uncertainty regarding penetration depth arises in treating animals. This study was designed to test the hypothesis that transmission of LLLT in horses is increased by clipping the hair and/or by cleaning the area to be treated with alcohol, but is unaffected by coat colour. A LLLT probe (810 nm, 500 mW was applied to the medial aspect of the superficial flexor tendon of seventeen equine forelimbs in vivo. A light sensor was applied to the lateral aspect, directly opposite the laser probe to measure the amount of light transmitted. Light transmission was not affected by individual horse, coat colour or leg. However, it was associated with leg condition (F = 4.42, p = 0.0032. Tendons clipped dry and clipped and cleaned with alcohol, were both associated with greater transmission of light than the unprepared state. Use of alcohol without clipping was not associated with an increase in light transmission. These results suggest that, when applying laser to a subcutaneous structure in the horse, the area should be clipped and cleaned beforehand.

  5. Determination of linear defect depths from eddy currents disturbances

    Science.gov (United States)

    Ramos, Helena Geirinhas; Rocha, Tiago; Pasadas, Dário; Ribeiro, Artur Lopes

    2014-02-01

    One of the still open problems in the inspection research concerns the determination of the maximum depth to which a surface defect goes. Eddy current testing being one of the most sensitive well established inspection methods, able to detect and characterize different type of defects in conductive materials, is an adequate technique to solve this problem. This paper reports a study concerning the disturbances in the magnetic field and in the lines of current due to a machined linear defect having different depths in order to extract relevant information that allows the determination of the defect characteristics. The image of the eddy currents (EC) is paramount to understand the physical phenomena involved. The EC images for this study are generated using a commercial finite element model (FLUX). The excitation used produces a uniform magnetic field on the plate under test in the absence of defects and the disturbances due to the defects are compared with those obtained from experimental measurements. In order to increase the limited penetration depth of the method giant magnetoresistors (GMR) are used to lower the working frequency. The geometry of the excitation planar coil produces a uniform magnetic field on an area of around the GMR sensor, inducing a uniform eddy current distribution on the plate. In the presence of defects in the material surface, the lines of currents inside the material are deviated from their uniform direction and the magnetic field produced by these currents is sensed by the GMR sensor. Besides the theoretical study of the electromagnetic system, the paper describes the experiments that have been carried out to support the theory and conclusions are drawn for cracks having different depths.

  6. Accuracy of probing attachment levels using a new computerized cemento-enamel junction probe.

    Science.gov (United States)

    Deepa, R; Prakash, Shobha

    2012-01-01

    The assessment of clinical attachment level (CAL) represents the gold standard for diagnosing and monitoring periodontal disease. The aim of the present study was to evaluate the performance of the newly introduced cemento-enamel junction (CEJ) probe in detecting CAL, using CEJ as a fixed reference point, and to compare the CEJ probe with the Florida stent probe (FSP) as well as with a standard manual probe, University of North Carolina-15 (UNC-15). Three examiners recorded the probing attachment level in 384 sites in case group (chronic periodontitis), and in 176 sites, in control group (healthy periodontal status), using the three probes. Subjects included both the sexes and ranged from 35 to 45 years. The experimental design was structured to balance the intra- and inter-examiner consistency at the same site during the two visits. CEJ probe showed higher intra-and inter-examiner consistency over both FSP and UNC-15 in both the case and control groups. Frequency distribution of differences of various magnitudes of repeated measurements ≤1 mm was in the higher range of 86.8% to 87.5% for CEJ probe. The FSP was more reproducible than UNC-15 in detecting relative attachment level (RAL). CEJ automated probe was found to have greatest potential for accuracy and consistency in detecting CAL than FSP and UNC-15. The automated probes appeared to be more reproducible than manual probes.

  7. Study of time variation of terrestrial gamma radiation due to depth distribution of soil moisture content

    International Nuclear Information System (INIS)

    Yoshioka, Katsuhiro

    1994-01-01

    An empirical equation was deduced from studies of time variations of terrestrial gamma exposure rate and soil moisture content with depth distribution in the surface layer. It was definitely suggested that the variation of terrestrial gamma exposure rate is most strongly influenced by the change of soil moisture content at 5 cm depth. The seasonal variation with a relative maximum in early autumn and a relative minimum in early spring was clearly obtained in the consequence of long time measurements of terrestrial gamma exposure rate and degree of soil dryness. The diurnal change and phase difference due to the effect of depth were also obtained in the dynamic characteristics of soil moisture content at 3 different depths. From the comparison between measured terrestrial gamma exposure rate and that evaluated from soil moisture content using the empirical equation, it was seen that seasonal variations of the both agreed fairly well as a whole. (author)

  8. Post-cure depth of cure of bulk fill dental resin-composites.

    Science.gov (United States)

    Alrahlah, A; Silikas, N; Watts, D C

    2014-02-01

    To determine the post-cure depth of cure of bulk fill resin composites through using Vickers hardness profiles (VHN). Five bulk fill composite materials were examined: Tetric EvoCeram(®) Bulk Fill, X-tra base, Venus(®) Bulk Fill, Filtek™ Bulk Fill, SonicFill™. Three specimens of each material type were prepared in stainless steel molds which contained a slot of dimensions (15 mm × 4 mm × 2 mm), and a top plate. The molds were irradiated from one end. All specimens were stored at 37°C for 24h, before measurement. The Vickers hardness was measured as a function of depth of material, at 0.3mm intervals. Data were analysed by one-way ANOVA using Tukey post hoc tests (α=0.05). The maximum VHN ranged from 37.8 to 77.4, whilst the VHN at 80% of max.VHN ranged from 30.4 to 61.9. The depth corresponding to 80% of max.VHN, ranged from 4.14 to 5.03 mm. One-way ANOVA showed statistically significant differences between materials for all parameters tested. SonicFill exhibited the highest VHN (pFill the lowest (p≤0.001). SonicFill and Tetric EvoCeram Bulk Fill had the greatest depth of cure (5.03 and 4.47 mm, respectively) and was significant's different from X-tra base, Venus Bulk Fill and Filtek Bulk Fill (p≤0.016). Linear regression confirmed a positive regression between max.VHN and filler loading (r(2)=0.94). Bulk fill resin composites can be cured to an acceptable post-cure depth, according to the manufacturers' claims. SonicFill and Tetric EvoCeram Bulk Fill had the greatest depth of cure among the composites examined. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. Improving Focal Depth Estimates: Studies of Depth Phase Detection at Regional Distances

    Science.gov (United States)

    Stroujkova, A.; Reiter, D. T.; Shumway, R. H.

    2006-12-01

    The accurate estimation of the depth of small, regionally recorded events continues to be an important and difficult explosion monitoring research problem. Depth phases (free surface reflections) are the primary tool that seismologists use to constrain the depth of a seismic event. When depth phases from an event are detected, an accurate source depth is easily found by using the delay times of the depth phases relative to the P wave and a velocity profile near the source. Cepstral techniques, including cepstral F-statistics, represent a class of methods designed for the depth-phase detection and identification; however, they offer only a moderate level of success at epicentral distances less than 15°. This is due to complexities in the Pn coda, which can lead to numerous false detections in addition to the true phase detection. Therefore, cepstral methods cannot be used independently to reliably identify depth phases. Other evidence, such as apparent velocities, amplitudes and frequency content, must be used to confirm whether the phase is truly a depth phase. In this study we used a variety of array methods to estimate apparent phase velocities and arrival azimuths, including beam-forming, semblance analysis, MUltiple SIgnal Classification (MUSIC) (e.g., Schmidt, 1979), and cross-correlation (e.g., Cansi, 1995; Tibuleac and Herrin, 1997). To facilitate the processing and comparison of results, we developed a MATLAB-based processing tool, which allows application of all of these techniques (i.e., augmented cepstral processing) in a single environment. The main objective of this research was to combine the results of three focal-depth estimation techniques and their associated standard errors into a statistically valid unified depth estimate. The three techniques include: 1. Direct focal depth estimate from the depth-phase arrival times picked via augmented cepstral processing. 2. Hypocenter location from direct and surface-reflected arrivals observed on sparse

  10. Empirical equations for the representation of depth dose data for computerized treatment planning

    International Nuclear Information System (INIS)

    Kornelsen, R.O.; Young, M.E.J.

    1975-01-01

    Equations of the form P = 100 (1 - (1 - exp ( -d/Q) )sup(M)) and TAR = S (1 - (1 - exp (-d/Q) ) sup(M) ) have been used to represent the variation of central axis percentage depth dose P or tissue-air ratio (TAR) with depth d below the dose maximum. These equations were originally developed for the representation of cobalt 60 depth dose data but have also been fitted to the central axis depth dose data published in the British Journal of Radiology Supplement 11, for radiations ranging in energy from 1.5 mm Cu HVT to 8 MV. Values of the constants Q and M for standard field sizes are presented together with an estimate of the goodness of fit in each case. Two different approaches have been used in determining the dose at points other than those on the central axis. In the simpler method, used for rotation techniques, the off-axis ratio (OAR) was calculated from the equation: OAR = k 1 + (1 - k 1 ) 1/(1 + exp (k 2 (x - 0.5 w)))] where x is the off-axis distance, w the field width at the depth and k 1 and k 2 are constants. In the more accurate method, used for fixed field techniques, different equations were used within the main beam, within the geometrical penumbra and outside the beam. (author)

  11. DNA probes

    Energy Technology Data Exchange (ETDEWEB)

    Castelino, J

    1993-12-31

    The creation of DNA probes for detection of specific nucleotide segments differs from ligand detection in that it is a chemical rather than an immunological reaction. Complementary DNA or RNA is used in place of the antibody and is labelled with {sup 32}P. So far, DNA probes have been successfully employed in the diagnosis of inherited disorders, infectious diseases, and for identification of human oncogenes. The latest approach to the diagnosis of communicable and parasitic infections is based on the use of deoxyribonucleic acid (DNA) probes. The genetic information of all cells is encoded by DNA and DNA probe approach to identification of pathogens is unique because the focus of the method is the nucleic acid content of the organism rather than the products that the nucleic acid encodes. Since every properly classified species has some unique nucleotide sequences that distinguish it from every other species, each organism`s genetic composition is in essence a finger print that can be used for its identification. In addition to this specificity, DNA probes offer other advantages in that pathogens may be identified directly in clinical specimens 10 figs, 2 tabs

  12. Probe measurements for impurity transport in the scrape-off layer of JIPP T-II

    International Nuclear Information System (INIS)

    Mohri, M.; Satake, T.; Hashiba, H.; Yamashina, T.; Amemiya, S.

    1982-05-01

    Impurity transport processes in the scrape-off layer of the JIPP T-II device have been studied by a probe method. A cubical silicon probe was inserted and exposed to 20 identical tokamak discharges in the scrape-off region. Deposited impurities were analyzed with use of AES, RBS and PIXE equipments. The main metallic impurities were molybdenum and iron whose deposition behavior was almost the same on any side of the probe, and their fluxes were observed to be 1.2 x 10 13 /cm 2 .discharge on the electron drift side and 5.2 x 10 13 /cm 2 .discharge on the ion drift side, respectively at the distance of 18.3 cm from the center line of the plasma. The mean transport energy of the impurities striking the probe surface was estimated from the depth concentration profile applying the LSS theory for iron as 90 eV on the electron drift side and 250 eV on the ion drift side, respectively. The e-folding length of the scrape-off plasma density was measured by the radial distribution of a deposited tantalum amount to be 0.64 cm on the electron drift side and 1.73 cm on the ion drift side, respectively. (author)

  13. Prestack depth migration

    International Nuclear Information System (INIS)

    Postma, R.W.

    1991-01-01

    Two lines form the southern North Sea, with known velocity inhomogeneities in the overburden, have been pre-stack depth migrated. The pre-stack depth migrations are compared with conventional processing, one with severe distortions and one with subtle distortions on the conventionally processed sections. The line with subtle distortions is also compared with post-stack depth migration. The results on both lines were very successful. Both have already influenced drilling decisions, and have caused a modification of structural interpretation in the respective areas. Wells have been drilled on each of the lines, and well tops confirm the results. In fact, conventional processing led to incorrect locations for the wells, both of which were dry holes. The depth migrated sections indicate the incorrect placement, and on one line reveals a much better drilling location. This paper reports that even though processing costs are high for pre-stack depth migration, appropriate use can save millions of dollars in dry-hole expense

  14. Analysis of deuterium in V-Fe5at.% film by atom probe tomography (APT)

    International Nuclear Information System (INIS)

    Gemma, R.; Al-Kassab, T.; Kirchheim, R.; Pundt, A.

    2011-01-01

    Research highlights: → Deuterium distribution in V-Fe thin film was investigated by atom probe tomography. → Correct analysis was possible at analysis temperatures below 30 K. → Inhomogeneous distribution of D atoms was nevertheless observed. → This was interpreted by trapping effect at misfit dislocation. → Atom probe analysis provides detailed information on local chemistry of M-D system. - Abstract: V-Fe5at.% 2 and 10-nm thick single layered films were prepared by ion beam sputtering on W substrate. They were loaded with D from gas phase at 0.2 Pa and at 1 Pa, respectively. Both lateral and depth D distribution of these films was investigated in detail by atom probe tomography. The results of analysis are in good agreement between the average deuterium concentration and the value, expected from electromotive force measurement on a similar flat film. An enrichment of deuterium at the V/W interface was observed for both films. The origin of this D-accumulation was discussed in respect to electron transfer, mechanical stress and misfit dislocations.

  15. Corneal ablation depth readout of the MEL 80 excimer laser compared to Artemis three-dimensional very high-frequency digital ultrasound stromal measurements.

    Science.gov (United States)

    Reinstein, Dan Z; Archer, Timothy J; Gobbe, Marine

    2010-12-01

    To evaluate the accuracy of the ablation depth readout for the MEL 80 excimer laser (Carl Zeiss Meditec). Artemis 1 very high-frequency digital ultrasound measurements were obtained before and at least 3 months after LASIK in 121 eyes (65 patients). The Artemis-measured ablation depth was calculated as the maximum difference in stromal thickness before and after treatment. Laser in situ keratomileusis was performed using the MEL 80 excimer laser and the Hansatome microkeratome (Bausch & Lomb). The Aberration Smart Ablation profile was used in 56 eyes and the Tissue Saving Ablation profile was used in 65 eyes. All ablations were centered on the corneal vertex. Comparative statistics and linear regression analysis were performed between the laser readout ablation depth and Artemis-measured ablation depth. The mean maximum myopic meridian was -6.66±2.40 diopters (D) (range: -1.50 to -10.00 D) for Aberration Smart Ablation-treated eyes and -6.50±2.56 D (range: -1.34 to -11.50 D) for Tissue Saving Ablation-treated eyes. The MEL 80 readout was found to overestimate the Artemis-measured ablation depth by 20±12 μm for Aberration Smart Ablation and by 21±12 μm for Tissue Saving Ablation profiles. The accuracy of ablation depth measurement was improved by using the Artemis stromal thickness profile measurements before and after surgery to exclude epithelial changes. The MEL 80 readout was found to overestimate the achieved ablation depth. The linear regression equations could be used by MEL 80 users to adjust the ablation depth for predicted residual stromal thickness calculations without increasing the risk of ectasia due to excessive keratectomy depth as long as a suitable flap thickness bias is included. Copyright 2010, SLACK Incorporated.

  16. Effect of Roots on Infiltration Process around a Tree - an Application of Tension-TDR Probes

    Science.gov (United States)

    -Lun Li, Sheng; Liang, Wei-Li

    2014-05-01

    The infiltration processe around a tree is usually complex because of preferential pathways around roots. In order to clarify the effect of tree roots on the infiltration process, we simultaneously measured volumetric water content (θ) and metric potential (ψ) with a high-density installation of Tensio-TDR probes, which could provid in situ soil-water characteristic curves in a small area around tree roots. A tension-TDR probe includes a coiled time domain reflectometry (TDR) probe around the porous cup of a standard tensiometer. The investigation was carried out around a Taiwanese cedar (Taiwania cryptomerioides) in a mixed coniferous forested stand. There were 24 soil moisture sensors and 12 Tensio-TDR probes installed in different depths of two soil profiles, respectively. The result suggested that the Tensio-TDR probe is better to determine the occurrence of preferential flow around tree roots than soil moisture sensors. Woody roots promoted the occurrence of lateral flows and caused rapid increases of θ in the deeper soil layers. Soil porosity was high in the area with fine roots where infiltration was dominated by vertical flows. We also compared the difference betweenthe field and laboratory soil-water characteristic curves, which were determined by the θ and ψ datasets from the field and the measurement using pressure plate method in a laboratory, respectively.

  17. High bit depth infrared image compression via low bit depth codecs

    DEFF Research Database (Denmark)

    Belyaev, Evgeny; Mantel, Claire; Forchhammer, Søren

    2017-01-01

    images via 8 bit depth codecs in the following way. First, an input 16 bit depth image is mapped into 8 bit depth images, e.g., the first image contains only the most significant bytes (MSB image) and the second one contains only the least significant bytes (LSB image). Then each image is compressed.......264/AVC codecs, which are usually available in efficient implementations, and compare their rate-distortion performance with JPEG2000, JPEG-XT and H.265/HEVC codecs supporting direct compression of infrared images in 16 bit depth format. A preliminary result shows that two 8 bit H.264/AVC codecs can...

  18. Can a Soft Robotic Probe Use Stiffness Control Like a Human Finger to Improve Efficacy of Haptic Perception?

    Science.gov (United States)

    Sornkarn, Nantachai; Nanayakkara, Thrishantha

    2017-01-01

    When humans are asked to palpate a soft tissue to locate a hard nodule, they regulate the stiffness, speed, and force of the finger during examination. If we understand the relationship between these behavioral variables and haptic information gain (transfer entropy) during manual probing, we can improve the efficacy of soft robotic probes for soft tissue palpation, such as in tumor localization in minimally invasive surgery. Here, we recorded the muscle co-contraction activity of the finger using EMG sensors to address the question as to whether joint stiffness control during manual palpation plays an important role in the haptic information gain. To address this question, we used a soft robotic probe with a controllable stiffness joint and a force sensor mounted at the base to represent the function of the tendon in a biological finger. Then, we trained a Markov chain using muscle co-contraction patterns of human subjects, and used it to control the stiffness of the soft robotic probe in the same soft tissue palpation task. The soft robotic experiments showed that haptic information gain about the depth of the hard nodule can be maximized by varying the internal stiffness of the soft probe.

  19. Electroacoustic Process Study of Plasma Sparker Under Different Water Depth

    KAUST Repository

    Huang, Yifan

    2015-01-05

    The plasma sparker has been applied in oceanic high-resolution seismic exploration for decades. Normally it is towed on the water surface. This is suitable for shallow water, but if the water depth is great, the resolution will decrease dramatically, especially in the horizontal direction. This paper proposes the concept of a deep-towed plasma sparker and presents an experimental study of plasma sparker performance in terms of electric parameters, bubble behavior, and acoustic characteristics. The results show that hydrostatic pressure at a source depth ranging from 1 to 2000 m has a negligible influence on the electric parameters but a strong influence on bubble behavior, wherein both the maximum bubble radius and oscillation period are decreased. The collapse pulse vanishes when the source depth reaches 1000 m or deeper, and no bubble oscillation can be distinguished. The source level (evaluated by the expansion pulse) is also decreased as the source depth increases; moreover, the greater the discharge energy, the smaller the source level loss. The discharge energy per electrode should be greater than 20 J for the deep-towed plasma sparker, which can make the source level loss induced by hydrostatic pressure smaller than the transmission loss. The fast Fourier transform (FFT) results show that the dominant energy is around 20 kHz, which is mainly induced by the expansion pulse and its oscillation. According to the simulation results, the fundamental frequency of the acoustic waveform increases with source depth in accord with a log linear trend, and also reaches tens of kilohertz in deep water. So, before the development of deep-towed plasma sparker, a new technical solution will need to be developed to solve this problem. © 1976-2012 IEEE.

  20. The Influence of Prosodic Stress Patterns and Semantic Depth on Novel Word Learning in Typically Developing Children.

    Science.gov (United States)

    Gladfelter, Allison; Goffman, Lisa

    2013-01-01

    The goal of this study was to investigate the effects of prosodic stress patterns and semantic depth on word learning. Twelve preschool-aged children with typically developing speech and language skills participated in a word learning task. Novel words with either a trochaic or iambic prosodic pattern were embedded in one of two learning conditions, either in children's stories (semantically rich) or picture matching games (semantically sparse). Three main analyses were used to measure word learning: comprehension and production probes, phonetic accuracy, and speech motor stability. Results revealed that prosodic frequency and density influence the learnability of novel words, or that there are prosodic neighborhood density effects. The impact of semantic depth on word learning was minimal and likely depends on the amount of experience with the novel words.

  1. Probe Storage

    NARCIS (Netherlands)

    Gemelli, Marcellino; Abelmann, Leon; Engelen, Johannes Bernardus Charles; Khatib, M.G.; Koelmans, W.W.; Zaboronski, Olog; Campardo, Giovanni; Tiziani, Federico; Laculo, Massimo

    2011-01-01

    This chapter gives an overview of probe-based data storage research over the last three decades, encompassing all aspects of a probe recording system. Following the division found in all mechanically addressed storage systems, the different subsystems (media, read/write heads, positioning, data

  2. Campbell penetration depth in Fe-based superconductors

    International Nuclear Information System (INIS)

    Prommapan, Plegchart

    2011-01-01

    A 'true' critical current density, j c , as opposite to commonly measured relaxed persistent (Bean) current, j B , was extracted from the Campbell penetration depth, λ c (T,H) measured in single crystals of LiFeAs, and optimally electron-doped Ba(Fe 0.954 Ni 0.046 ) 2 As 2 (FeNi122). In LiFeAs, the effective pinning potential is nonparabolic, which follows from the magnetic field - dependent Labusch parameter α. At the equilibrium (upon field - cooling), α(H) is non-monotonic, but it is monotonic at a finite gradient of the vortex density. This behavior leads to a faster magnetic relaxation at the lower fields and provides a natural dynamic explanation for the fishtail (second peak) effect. We also find the evidence for strong pinning at the lower fields.The inferred field dependence of the pinning potential is consistent with the evolution from strong pinning, through collective pinning, and eventually to a disordered vortex lattice. The value of j c (2 K) ≅ 1.22 x 10 6 A/cm 2 provide an upper estimate of the current carrying capability of LiFeAs. Overall, vortex behavior of almost isotropic, fully-gapped LiFeAs is very similar to highly anisotropic d-wave cuprate superconductors, the similarity that requires further studies in order to understand unconventional superconductivity in cuprates and pnictides. In addition to LiFeAs, we also report the magnetic penetration depth in BaFe 2 As 2 based superconductors including irradiation of FeNi122. In unirradiated FeNi122, the maximum critical current value is, j c (2K) ≅ 3.3 x 10 6 A/cm 2 . The magnetic-dependent feature was observed near the transition temperature in FeTe 0.53 Se 0.47 and irradiated FeNi122. Because of this feature, further studies are required in order to properly calibrate the Campbell penetration depth. Finally, we detected the crossing between the magnetic penetration depth and London penetration depth in optimally hold-doped Ba 0.6 K 0.4 Fe 2 As 2 (BaK122) and isovalent doped BaFe 2 (As 0

  3. Real-time scintillation probe measurement of left ventricular function

    International Nuclear Information System (INIS)

    Green, M.V.; Ostrow, H.G.; Bacharach, S.L.; Allen, S.I.; Bonow, R.O.; Johnston, G.S.

    1981-01-01

    The micro-processor based system described in this report was designed for maximum flexibility and utility. While the principle function of the system is to acquire, create, analyze and display (in real-time) left ventricular time activity (or volume) curves, provision is also made to acquire additional physiologic signals (e.g., ECG, flowmeter, etc.) and to calculate and display relationships between these various data. The system was designed for interactive use so that the system user can alter the course of a series of measurements based on previous results. These general capabilities are illustrated with several examples. In the first, LV function was measured continuously in a subject from (supine) rest through exercise and recovery. The second example illustrates the use of the system in acquiring (LV) pressure-volume loops. Several technical problems, such as correction for LV background radiation, appear at present to limit the probes applicability. Even now, however, probe systems are demonstrably useful in the study of global left ventricular function when this function is changing rapidly with time in response to various interventions. (orig.) [de

  4. Sea Water Characterization at Ujung Kulon Coastal Depth as Raw Water Source for Desalination and Potential Energy

    Directory of Open Access Journals (Sweden)

    Mugisidi Dan

    2018-01-01

    Full Text Available Fresh water is basic need for life while the source is limited. Therefore, sea water is used as fresh water through desalination process. Sea water has different physical and chemical properties ranging from the surface to the seabed. The energy potential that can be obtained from the hydrostatic pressure also changes according to the depth. As part of the research of the utilization of sea water into fresh water, the aim of this study is to know the characteristics of sea water in the depth that can be utilized as source of fresh water. The sea water samples were taken at 11km from Ujung Kulon beach with depth of 0m, 20m, 40m, 60m, 80m, and 100m under the surface. The results showed that the physical properties at every depth were below the maximum allowable drinking water except for the amount of dissolved solids. Chemical characteristics at any depth above allowable level were fluoride, hardness (CaCo3, chloride, sodium, sulphate, and (KMnO4. In addition to the properties, pressure is one of the considerations in this study to determine the depth of sea water as sources for desalination. Pressure increased by 36.11% as the depth of the sea increased.

  5. Sea Water Characterization at Ujung Kulon Coastal Depth as Raw Water Source for Desalination and Potential Energy

    Science.gov (United States)

    Mugisidi, Dan; Heriyani, Okatrina

    2018-02-01

    Fresh water is basic need for life while the source is limited. Therefore, sea water is used as fresh water through desalination process. Sea water has different physical and chemical properties ranging from the surface to the seabed. The energy potential that can be obtained from the hydrostatic pressure also changes according to the depth. As part of the research of the utilization of sea water into fresh water, the aim of this study is to know the characteristics of sea water in the depth that can be utilized as source of fresh water. The sea water samples were taken at 11km from Ujung Kulon beach with depth of 0m, 20m, 40m, 60m, 80m, and 100m under the surface. The results showed that the physical properties at every depth were below the maximum allowable drinking water except for the amount of dissolved solids. Chemical characteristics at any depth above allowable level were fluoride, hardness (CaCo3), chloride, sodium, sulphate, and (KMnO4). In addition to the properties, pressure is one of the considerations in this study to determine the depth of sea water as sources for desalination. Pressure increased by 36.11% as the depth of the sea increased.

  6. Modular Rake of Pitot Probes

    Science.gov (United States)

    Dunlap, Timothy A.; Henry, Michael W.; Homyk, Raymond P.

    2004-01-01

    The figure presents selected views of a modular rake of 17 pitot probes for measuring both transient and steady-state pressures in a supersonic wind tunnel. In addition to pitot tubes visible in the figure, the probe modules contain (1) high-frequency dynamic-pressure transducers connected through wires to remote monitoring circuitry and (2) flow passages that lead to tubes that, in turn, lead to remote steady-state pressure transducers. Prior pitot-probe rakes were fabricated as unitary structures, into which the individual pitot probes were brazed. Repair or replacement of individual probes was difficult, costly, and time-consuming because (1) it was necessary to remove entire rakes in order to unbraze individual malfunctioning probes and (2) the heat of unbrazing a failed probe and of brazing a new probe in place could damage adjacent probes. In contrast, the modules in the present probe are designed to be relatively quickly and easily replaceable with no heating and, in many cases, without need for removal of the entire rake from the wind tunnel. To remove a malfunctioning probe, one first removes a screw-mounted V-cross-section cover that holds the probe and adjacent probes in place. Then one removes a screw-mounted cover plate to gain access to the steady-state pressure tubes and dynamicpressure wires. Next, one disconnects the tube and wires of the affected probe. Finally, one installs a new probe in the reverse of the aforementioned sequence. The wire connections can be made by soldering, but to facilitate removal and installation, they can be made via miniature plugs and sockets. The connections between the probe flow passages and the tubes leading to the remote pressure sensors can be made by use of any of a variety of readily available flexible tubes that can be easily pulled off and slid back on for removal and installation, respectively.

  7. STM-SQUID probe microscope

    International Nuclear Information System (INIS)

    Hayashi, Tadayuki; Tachiki, Minoru; Itozaki, Hideo

    2007-01-01

    We have developed a STM-SQUID probe microscope. A high T C SQUID probe microscope was combined with a scanning tunneling microscope for investigation of samples at room temperature in air. A high permeability probe needle was used as a magnetic flux guide to improve the spatial resolution. The probe with tip radius of less than 100 nm was prepared by microelectropolishing. The probe was also used as a scanning tunneling microscope tip. Topography of the sample surface could be measured by the scanning tunneling microscope with high spatial resolution prior to observation by SQUID microscopy. The SQUID probe microscope image could be observed while keeping the distance from the sample surface to the probe tip constant. We observed a topographic image and a magnetic image of Ni fine pattern and also a magnetically recorded hard disk. Furthermore we have investigated a sample vibration method of the static magnetic field emanating from a sample with the aim of achieving a higher signal-to-noise (S/N) ratio

  8. Characterization of coating probe with Ti-DLC for electrical scanning probe microscope

    International Nuclear Information System (INIS)

    Shia Xiaolei; Guo Liqiu; Bai Yang; Qiao Lijie

    2011-01-01

    In electrical scanning probe microscope (ESPM) applications, the wear and conductivity of the probe are undoubtedly serious concerns since they affect the integrity of the measurements. This study investigates the characterization of Ti doped diamond-like-carbon (DLC) as coating material on a silicon cantilever for ESPM. We deposited a layer of Ti-DLC thin film on the surface of Si cantilever by magnetron sputtering. The morphology and composition of the Ti-DLC films were characterized by scanning electron microscopy and Raman spectroscopy, respectively. We also compared the wear resistance, electric conductivity and scanning image quality of the Ti-DLC-coated probes with those of commercially available conductive probes. The results showed that the electric conductivity and the scanning image quality of the Ti-DLC-coated probes were the same as the commercial conductive probes, while the wear resistance and service life was significantly better.

  9. Broadband seismic noise attenuation versus depth at the Albuquerque Seismological Laboratory

    Science.gov (United States)

    Hutt, Charles R.; Ringler, Adam; Gee, Lind

    2017-01-01

    maximum burial depth within the budget when there is interest in using the data for low‐frequency applications. For long‐term deployments like the permanent observatories of the GSN and similar networks, 100–200 m depth in hard rock is desirable to achieve lowest noise, although 30–60 m may be acceptable.

  10. Physiological and biomechanical responses to walking underwater on a non-motorised treadmill: effects of different exercise intensities and depths in middle-aged healthy women.

    Science.gov (United States)

    Benelli, Piero; Colasanti, Franca; Ditroilo, Massimiliano; Cuesta-Vargas, Antonio; Gatta, Giorgio; Giacomini, Francesco; Lucertini, Francesco

    2014-01-01

    Non-motorised underwater treadmills are commonly used in fitness activities. However, no studies have examined physiological and biomechanical responses of walking on non-motorised treadmills at different intensities and depths. Fifteen middle-aged healthy women underwent two underwater walking tests at two different depths, immersed either up to the xiphoid process (deep water) or the iliac crest (shallow water), at 100, 110, 120, 130 step-per-minute (spm). Oxygen consumption (VO2), heart rate (HR), blood lactate concentration, perceived exertion and step length were determined. Compared to deep water, walking in shallow water exhibited, at all intensities, significantly higher VO2 (+13.5%, on average) and HR (+8.1%, on average) responses. Water depth did not influence lactate concentration, whereas perceived exertion was higher in shallow compared to deep water, solely at 120 (+40%) and 130 (+39.4%) spm. Average step length was reduced as the intensity increased (from 100 to 130 spm), irrespective of water depth. Expressed as a percentage of maximum, average VO2 and HR were: 64-76% of peak VO2 and 71-90% of maximum HR, respectively at both water depths. Accordingly, this form of exercise can be included in the "vigorous" range of exercise intensity, at any of the step frequencies used in this study.

  11. Defence in depth in nuclear safety learning from 'pre-symptomatic diseases'

    International Nuclear Information System (INIS)

    Fukuyama, Shigeru

    2011-01-01

    Traditional Chinese medicine argued 'pre-symptomatic diseases', which encouraged for a physician to treat before the ailment occurred. This article described such prophylactic concept was compared to that of defense in depth in nuclear safety, which suggested encouragement of daily activities with safety awareness, preventive maintenance and appropriate treatment for incidents of aged plants would reduce or mitigate their effects. Area of safety culture was also included. Importance of human resources development for safety culture and need of establishment of database concerning new knowledge and experiences were highly recommended. In reality various slight events, whose level of the International Nuclear Event Scale (INES) were less than 2, occurred before a large accident happened to occur. Efforts to reduce events whose level of INES was less than 2 or precursor of accidents would prevent level 3 serious accidents as maximum accident of defense in depth or mitigate the extension to a larger accident. (T. Tanaka)

  12. A novel probe of intrinsic electronic structure: hard X-ray photoemission spectroscopy

    International Nuclear Information System (INIS)

    Takata, Y.; Tamasaku, K.; Nishino, Y.; Miwa, D.; Yabashi, M.; Ikenaga, E.; Horiba, K.; Arita, M.; Shimada, K.; Namatame, H.; Nohira, H.; Hattori, T.; Soedergren, S.; Wannberg, B.; Taniguchi, M.; Shin, S.; Ishikawa, T.; Kobayashi, K.

    2005-01-01

    We have realized hard X-ray (HX) photoemission spectroscopy (PES) with high throughput and high-energy resolution for core level and valence band studies using high-energy and high-brilliance synchrotron radiation at SPring-8. This is a brand new method because large escape depth of high-energy photoelectrons enables us to probe intrinsic bulk states free from surface condition. By use of a newly developed electron energy analyzer and well-focused X-rays, high-energy resolution of 75 meV (E/ΔE 79,000) was realized for 5.95 keV photoelectrons

  13. Muons in air showers at the Pierre Auger Observatory: Measurement of atmospheric production depth

    Science.gov (United States)

    Aab, A.; Abreu, P.; Aglietta, M.; Ahlers, M.; Ahn, E. J.; Al Samarai, I.; Albuquerque, I. F. M.; Allekotte, I.; Allen, J.; Allison, P.; Almela, A.; Alvarez Castillo, J.; Alvarez-Muñiz, J.; Alves Batista, R.; Ambrosio, M.; Aminaei, A.; Anchordoqui, L.; Andringa, S.; Aramo, C.; Arqueros, F.; Asorey, H.; Assis, P.; Aublin, J.; Ave, M.; Avenier, M.; Avila, G.; Badescu, A. M.; Barber, K. B.; Bäuml, J.; Baus, C.; Beatty, J. J.; Becker, K. H.; Bellido, J. A.; Berat, C.; Bertou, X.; Biermann, P. L.; Billoir, P.; Blanco, F.; Blanco, M.; Bleve, C.; Blümer, H.; Boháčová, M.; Boncioli, D.; Bonifazi, C.; Bonino, R.; Borodai, N.; Brack, J.; Brancus, I.; Brogueira, P.; Brown, W. C.; Buchholz, P.; Bueno, A.; Buscemi, M.; Caballero-Mora, K. S.; Caccianiga, B.; Caccianiga, L.; Candusso, M.; Caramete, L.; Caruso, R.; Castellina, A.; Cataldi, G.; Cazon, L.; Cester, R.; Chavez, A. G.; Cheng, S. H.; Chiavassa, A.; Chinellato, J. A.; Chudoba, J.; Cilmo, M.; Clay, R. W.; Cocciolo, G.; Colalillo, R.; Collica, L.; Coluccia, M. R.; Conceição, R.; Contreras, F.; Cooper, M. J.; Coutu, S.; Covault, C. E.; Criss, A.; Cronin, J.; Curutiu, A.; Dallier, R.; Daniel, B.; Dasso, S.; Daumiller, K.; Dawson, B. R.; de Almeida, R. M.; De Domenico, M.; de Jong, S. J.; de Mello Neto, J. R. T.; De Mitri, I.; de Oliveira, J.; de Souza, V.; del Peral, L.; Deligny, O.; Dembinski, H.; Dhital, N.; Di Giulio, C.; Di Matteo, A.; Diaz, J. C.; Díaz Castro, M. L.; Diep, P. N.; Diogo, F.; Dobrigkeit, C.; Docters, W.; D'Olivo, J. C.; Dong, P. N.; Dorofeev, A.; Dorosti Hasankiadeh, Q.; Dova, M. T.; Ebr, J.; Engel, R.; Erdmann, M.; Erfani, M.; Escobar, C. O.; Espadanal, J.; Etchegoyen, A.; Facal San Luis, P.; Falcke, H.; Fang, K.; Farrar, G.; Fauth, A. C.; Fazzini, N.; Ferguson, A. P.; Fernandes, M.; Fick, B.; Figueira, J. M.; Filevich, A.; Filipčič, A.; Fox, B. D.; Fratu, O.; Fröhlich, U.; Fuchs, B.; Fuji, T.; Gaior, R.; García, B.; Garcia Roca, S. T.; Garcia-Gamez, D.; Garcia-Pinto, D.; Garilli, G.; Gascon Bravo, A.; Gate, F.; Gemmeke, H.; Ghia, P. L.; Giaccari, U.; Giammarchi, M.; Giller, M.; Glaser, C.; Glass, H.; Gomez Albarracin, F.; Gómez Berisso, M.; Gómez Vitale, P. F.; Gonçalves, P.; Gonzalez, J. G.; Gookin, B.; Gorgi, A.; Gorham, P.; Gouffon, P.; Grebe, S.; Griffith, N.; Grillo, A. F.; Grubb, T. D.; Guardincerri, Y.; Guarino, F.; Guedes, G. P.; Hansen, P.; Harari, D.; Harrison, T. A.; Harton, J. L.; Haungs, A.; Hebbeker, T.; Heck, D.; Heimann, P.; Herve, A. E.; Hill, G. C.; Hojvat, C.; Hollon, N.; Holt, E.; Homola, P.; Hörandel, J. R.; Horvath, P.; Hrabovský, M.; Huber, D.; Huege, T.; Insolia, A.; Isar, P. G.; Islo, K.; Jandt, I.; Jansen, S.; Jarne, C.; Josebachuili, M.; Kääpä, A.; Kambeitz, O.; Kampert, K. H.; Kasper, P.; Katkov, I.; Kégl, B.; Keilhauer, B.; Keivani, A.; Kemp, E.; Kieckhafer, R. M.; Klages, H. O.; Kleifges, M.; Kleinfeller, J.; Krause, R.; Krohm, N.; Krömer, O.; Kruppke-Hansen, D.; Kuempel, D.; Kunka, N.; La Rosa, G.; LaHurd, D.; Latronico, L.; Lauer, R.; Lauscher, M.; Lautridou, P.; Le Coz, S.; Leão, M. S. A. B.; Lebrun, D.; Lebrun, P.; Leigui de Oliveira, M. A.; Letessier-Selvon, A.; Lhenry-Yvon, I.; Link, K.; López, R.; Lopez Agüera, A.; Louedec, K.; Lozano Bahilo, J.; Lu, L.; Lucero, A.; Ludwig, M.; Lyberis, H.; Maccarone, M. C.; Malacari, M.; Maldera, S.; Maller, J.; Mandat, D.; Mantsch, P.; Mariazzi, A. G.; Marin, V.; Mariş, I. C.; Marsella, G.; Martello, D.; Martin, L.; Martinez, H.; Martínez Bravo, O.; Martraire, D.; Masías Meza, J. J.; Mathes, H. J.; Mathys, S.; Matthews, A. J.; Matthews, J.; Matthiae, G.; Maurel, D.; Maurizio, D.; Mayotte, E.; Mazur, P. O.; Medina, C.; Medina-Tanco, G.; Melissas, M.; Melo, D.; Menichetti, E.; Menshikov, A.; Messina, S.; Meyhandan, R.; Mićanović, S.; Micheletti, M. I.; Middendorf, L.; Minaya, I. A.; Miramonti, L.; Mitrica, B.; Molina-Bueno, L.; Mollerach, S.; Monasor, M.; Monnier Ragaigne, D.; Montanet, F.; Morello, C.; Moreno, J. C.; Mostafá, M.; Moura, C. A.; Muller, M. A.; Müller, G.; Münchmeyer, M.; Mussa, R.; Navarra, G.; Navas, S.; Necesal, P.; Nellen, L.; Nelles, A.; Neuser, J.; Niechciol, M.; Niemietz, L.; Niggemann, T.; Nitz, D.; Nosek, D.; Novotny, V.; Nožka, L.; Ochilo, L.; Olinto, A.; Oliveira, M.; Ortiz, M.; Pacheco, N.; Pakk Selmi-Dei, D.; Palatka, M.; Pallotta, J.; Palmieri, N.; Papenbreer, P.; Parente, G.; Parra, A.; Pastor, S.; Paul, T.; Pech, M.; PÈ©kala, J.; Pelayo, R.; Pepe, I. M.; Perrone, L.; Pesce, R.; Petermann, E.; Peters, C.; Petrera, S.; Petrolini, A.; Petrov, Y.; Piegaia, R.; Pierog, T.; Pieroni, P.; Pimenta, M.; Pirronello, V.; Platino, M.; Plum, M.; Porcelli, A.; Porowski, C.; Prado, R. R.; Privitera, P.; Prouza, M.; Purrello, V.; Quel, E. J.; Querchfeld, S.; Quinn, S.; Rautenberg, J.; Ravel, O.; Ravignani, D.; Revenu, B.; Ridky, J.; Riggi, S.; Risse, M.; Ristori, P.; Rizi, V.; Roberts, J.; Rodrigues de Carvalho, W.; Rodriguez Cabo, I.; Rodriguez Fernandez, G.; Rodriguez Rojo, J.; Rodríguez-Frías, M. D.; Ros, G.; Rosado, J.; Rossler, T.; Roth, M.; Roulet, E.; Rovero, A. C.; Rühle, C.; Saffi, S. J.; Saftoiu, A.; Salamida, F.; Salazar, H.; Saleh, A.; Salesa Greus, F.; Salina, G.; Sánchez, F.; Sanchez-Lucas, P.; Santo, C. E.; Santos, E.; Santos, E. M.; Sarazin, F.; Sarkar, B.; Sarmento, R.; Sato, R.; Scharf, N.; Scherini, V.; Schieler, H.; Schiffer, P.; Schmidt, A.; Scholten, O.; Schoorlemmer, H.; Schovánek, P.; Schulz, A.; Schulz, J.; Sciutto, S. J.; Segreto, A.; Settimo, M.; Shadkam, A.; Shellard, R. C.; Sidelnik, I.; Sigl, G.; Sima, O.; Śmiałkowski, A.; Šmída, R.; Snow, G. R.; Sommers, P.; Sorokin, J.; Squartini, R.; Srivastava, Y. N.; Stanič, S.; Stapleton, J.; Stasielak, J.; Stephan, M.; Stutz, A.; Suarez, F.; Suomijärvi, T.; Supanitsky, A. D.; Sutherland, M. S.; Swain, J.; Szadkowski, Z.; Szuba, M.; Taborda, O. A.; Tapia, A.; Tartare, M.; Thao, N. T.; Theodoro, V. M.; Tiffenberg, J.; Timmermans, C.; Todero Peixoto, C. J.; Toma, G.; Tomankova, L.; Tomé, B.; Tonachini, A.; Torralba Elipe, G.; Torres Machado, D.; Travnicek, P.; Trovato, E.; Tueros, M.; Ulrich, R.; Unger, M.; Urban, M.; Valdés Galicia, J. F.; Valiño, I.; Valore, L.; van Aar, G.; van den Berg, A. M.; van Velzen, S.; van Vliet, A.; Varela, E.; Vargas Cárdenas, B.; Varner, G.; Vázquez, J. R.; Vázquez, R. A.; Veberič, D.; Verzi, V.; Vicha, J.; Videla, M.; Villaseñor, L.; Vlcek, B.; Vorobiov, S.; Wahlberg, H.; Wainberg, O.; Walz, D.; Watson, A. A.; Weber, M.; Weidenhaupt, K.; Weindl, A.; Werner, F.; Whelan, B. J.; Widom, A.; Wiencke, L.; Wilczyńska, B.; Wilczyński, H.; Will, M.; Williams, C.; Winchen, T.; Wittkowski, D.; Wundheiler, B.; Wykes, S.; Yamamoto, T.; Yapici, T.; Younk, P.; Yuan, G.; Yushkov, A.; Zamorano, B.; Zas, E.; Zavrtanik, D.; Zavrtanik, M.; Zaw, I.; Zepeda, A.; Zhou, J.; Zhu, Y.; Zimbres Silva, M.; Ziolkowski, M.; Pierre Auger Collaboration

    2014-07-01

    The surface detector array of the Pierre Auger Observatory provides information about the longitudinal development of the muonic component of extensive air showers. Using the timing information from the flash analog-to-digital converter traces of surface detectors far from the shower core, it is possible to reconstruct a muon production depth distribution. We characterize the goodness of this reconstruction for zenith angles around 60° and different energies of the primary particle. From these distributions, we define Xmaxμ as the depth along the shower axis where the production of muons reaches maximum. We explore the potentiality of Xmaxμ as a useful observable to infer the mass composition of ultrahigh-energy cosmic rays. Likewise, we assess its ability to constrain hadronic interaction models.

  14. Results of testing the E9 multiple probe lateral logging device in deep wells in the eastern Pre-caucasus

    Energy Technology Data Exchange (ETDEWEB)

    Boyarchuk, A.F.; Kochetkov, V.T.; Kucherov, R.A.

    1981-07-01

    The integrated lateral logging device E9 developed for investigating deep and extra-deep wells, permitting measurement of apparent resistances by three probes at different depths, is described. It is heat and pressure resistant (up to 200/degree/C, 120 MPa). The tests showed that under certain favorable conditions the device is fairly effective.

  15. Impact of the depth of the wells and multifractal analysis on stochastic resonance in a triple-well system

    International Nuclear Information System (INIS)

    Arathi, S; Rajasekar, S

    2011-01-01

    We analyze the stochastic resonance in a symmetric triple-well system with the depths of the wells being different. The system is subjected to a weak periodic force and Gaussian white noise with strength D. We show that the optimum value of noise intensity (D MAX ) is minimum, while the signal-to-noise ratio is maximum when the ratio (R) of the depths of the middle and side wells is 1. At D MAX , the particle enters the middle well twice during every period of the external periodic force. When the depths of the three wells are equal (R=1), the mean residence time (T MR ) in each well is T/4, where T is the period of the driving force. T MR varies with parameter R; however, periodicity in switching is observed at D MAX for any value of R. The generalized dimensions D q decrease with an increase in noise intensity D, reach a minimum at D=D MAX and then increase for all values of R. The α-f(α) spectrum is always of incomplete concave shape with f(α min )=0, while f(α max )≠0 at any value of D and, moreover, the maximum value of α is minimum at D=D MAX .

  16. Maximum permissible dose

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    This chapter presents a historic overview of the establishment of radiation guidelines by various national and international agencies. The use of maximum permissible dose and maximum permissible body burden limits to derive working standards is discussed

  17. Monitoring massive fracture growth at 2-km depths using surface tiltmeter arrays

    Science.gov (United States)

    Wood, M.D.

    1979-01-01

    Tilt due to massive hydraulic fractures induced in sedimentary rocks at depths of up to 2.2 km have been recorded by surface tiltmeters. Injection of fluid volumes up to 4 ?? 105 liters and masses of propping agent up to 5 ?? 105 kg is designed to produce fractures approximately 1 km long, 50-100 m high and about 1 cm wide. The surface tilt data adequately fit a dislocation model of a tensional fault in a half-space. Theoretical and observational results indicate that maximum tilt occurs at a distance off the strike of the fracture equivalent to 0.4 of the depth to the fracture. Azimuth and extent of the fracture deduced from the geometry of the tilt field agree with other kinds of geophysical measurements. Detailed correlation of the tilt signatures with pumping parameters (pressure, rate, volume, mass) have provided details on asymmetry in geometry and growth rate. Whereas amplitude variations in tilt vary inversely with the square of the depth, changes in flow rate or pressure gradient can produce a cubic change in width. These studies offer a large-scale experimental approach to the study of problems involving fracturing, mass transport, and dilatancy processes. ?? 1979.

  18. Dopant density from maximum-minimum capacitance ratio of implanted MOS structures

    International Nuclear Information System (INIS)

    Brews, J.R.

    1982-01-01

    For uniformly doped structures, the ratio of the maximum to the minimum high frequency capacitance determines the dopant ion density per unit volume. Here it is shown that for implanted structures this 'max-min' dopant density estimate depends upon the dose and depth of the implant through the first moment of the depleted portion of the implant. A a result, the 'max-min' estimate of dopant ion density reflects neither the surface dopant density nor the average of the dopant density over the depletion layer. In particular, it is not clear how this dopant ion density estimate is related to the flatband capacitance. (author)

  19. Positron Annihilation Spectroscopy as a Novel Interfacial Probe for Thin Polymeric Films and Nano-Composites

    Science.gov (United States)

    Awad, Somia; Chen, Hongmin; Maina, Grace; Lee, L. James; Gu, Xiaohong; Jean, Y. C.

    2010-03-01

    Positron annihilation spectroscopy (PAS) has been developed as a novel probe to characterize the sub-nanometer defect, free volume, profile from the surface, interfaces, and to the bulk in polymeric materials when a variable mono-energy slow positron beam is used. Free-volume hole sizes, fractions, and distributions are measurable as a function of depth at the high precision. PAS has been successfully used to study the interfacial properties of polymeric nanocomposites at different chemical bonding. In nano-scale thin polymeric films, such as in PS/SiO2, and PU/ZnO, significant variations of Tg as a function of depth and of wt% oxide are observed. Variations of Tg are dependent on strong or weak interactions between polymers and nano-scale oxides surfaces.

  20. Proximal Probes Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Proximal Probes Facility consists of laboratories for microscopy, spectroscopy, and probing of nanostructured materials and their functional properties. At the...

  1. Complexity and Dynamical Depth

    Directory of Open Access Journals (Sweden)

    Terrence Deacon

    2014-07-01

    Full Text Available We argue that a critical difference distinguishing machines from organisms and computers from brains is not complexity in a structural sense, but a difference in dynamical organization that is not well accounted for by current complexity measures. We propose a measure of the complexity of a system that is largely orthogonal to computational, information theoretic, or thermodynamic conceptions of structural complexity. What we call a system’s dynamical depth is a separate dimension of system complexity that measures the degree to which it exhibits discrete levels of nonlinear dynamical organization in which successive levels are distinguished by local entropy reduction and constraint generation. A system with greater dynamical depth than another consists of a greater number of such nested dynamical levels. Thus, a mechanical or linear thermodynamic system has less dynamical depth than an inorganic self-organized system, which has less dynamical depth than a living system. Including an assessment of dynamical depth can provide a more precise and systematic account of the fundamental difference between inorganic systems (low dynamical depth and living systems (high dynamical depth, irrespective of the number of their parts and the causal relations between them.

  2. Depth data research of GIS based on clustering analysis algorithm

    Science.gov (United States)

    Xiong, Yan; Xu, Wenli

    2018-03-01

    The data of GIS have spatial distribution. Geographic data has both spatial characteristics and attribute characteristics, and also changes with time. Therefore, the amount of data is very large. Nowadays, many industries and departments in the society are using GIS. However, without proper data analysis and mining scheme, GIS will not exert its maximum effectiveness and will waste a lot of data. In this paper, we use the geographic information demand of a national security department as the experimental object, combining the characteristics of GIS data, taking into account the characteristics of time, space, attributes and so on, and using cluster analysis algorithm. We further study the mining scheme for depth data, and get the algorithm model. This algorithm can automatically classify sample data, and then carry out exploratory analysis. The research shows that the algorithm model and the information mining scheme can quickly find hidden depth information from the surface data of GIS, thus improving the efficiency of the security department. This algorithm can also be extended to other fields.

  3. Introduction of argon beam coagulation functionality to robotic procedures using the ABC D-Flex probe: equivalency to an existing laparoscopic instrument

    Science.gov (United States)

    Merchel, Renée. A.; Barnes, Kelli S.; Taylor, Kenneth D.

    2015-03-01

    INTRODUCTION: The ABC® D-Flex Probe utilizes argon beam coagulation (ABC) technology to achieve hemostasis during minimally invasive surgery. A handle on the probe allows for integration with robotic surgical systems and introduces ABC to the robotic toolbox. To better understand the utility of D-Flex, this study compares the performance of the D-Flex probe to an existing ABC laparoscopic probe through ex vivo tissue analysis. METHODS: Comparisons were performed to determine the effect of four parameters: ABC device, tissue type, activation duration, and distance from tissue. Ten ABC D-Flex probes were used to create 30 burn samples for each comparison. Ex vivo bovine liver and porcine muscle were used as tissue models. The area and depth of each burn was measured using a light microscope. The resulting dimensional data was used to correlate tissue effect with each variable. RESULTS: D-Flex created burns which were smaller in surface area than the laparoscopic probe at all power levels. Additionally, D-Flex achieved thermal penetration levels equivalent to the laparoscopic probe. CONCLUSION: D-Flex implements a small 7F geometry which creates a more focused beam. When used with robotic precision, quick localized superficial hemostasis can be achieved with minimal collateral damage. Additionally, D-Flex achieved equivalent thermal penetration levels at lower power and argon flow-rate settings than the laparoscopic probe.

  4. An atomic-force-microscopy study of the structure of surface layers of intact fibroblasts

    Science.gov (United States)

    Khalisov, M. M.; Ankudinov, A. V.; Penniyaynen, V. A.; Nyapshaev, I. A.; Kipenko, A. V.; Timoshchuk, K. I.; Podzorova, S. A.; Krylov, B. V.

    2017-02-01

    Intact embryonic fibroblasts on a collagen-treated substrate have been studied by atomic-force microscopy (AFM) using probes of two types: (i) standard probes with tip curvature radii of 2-10 nm and (ii) special probes with a calibrated 325-nm SiO2 ball radius at the tip apex. It is established that, irrespective of probe type, the average maximum fibroblast height is on a level of 1.7 μm and the average stiffness of the probe-cell contact amounts to 16.5 mN/m. The obtained AFM data reveal a peculiarity of the fibroblast structure, whereby its external layers move as a rigid shell relative to the interior and can be pressed inside to a depth dependent on the load only.

  5. Assessment of an ultrasonic sensor and a capacitance probe for measurement of two-phase mixture level

    International Nuclear Information System (INIS)

    Kim, Chang Hyun; Lee, Dong Won; No, Hee Cheon

    2004-01-01

    We performed a comparison of two-phase mixture levels measured by an ultrasonic sensor and a two-wire type capacitance probe with visual data under the same experimental conditions. A series of experiments are performed with various combinations of airflow and initial water level using a test vessel with a height of 2m and an inner diameter of 0.3m. The ultrasonic sensor measured the two-phase mixture level with a maximum error of 1.77% with respect to the visual data. The capacitance probe severely under-predicted the level data in the high void fraction region. The cause of the error was identified as the change of the dielectric constant as the void fraction changes when the probe is applied to the measurement of the two-phase mixture levels. A correction method for the capacitance probe is proposed by correcting the change of the dielectric constant of the two-phase mixture. The correction method for the capacitance probe produces a r.m.s. error of 5.4%. The present experimental data are compared with the existing pool void fraction correlations based on drift-flux model. The Kataoka-Ishii correlation has the best agreement with the present experimental data with an r.m.s error of 2.5%

  6. Methodology for Calculating Latency of GPS Probe Data

    Energy Technology Data Exchange (ETDEWEB)

    Young, Stanley E [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Wang, Zhongxiang [University of Maryland; Hamedi, Masoud [University of Maryland

    2017-10-01

    Crowdsourced GPS probe data, such as travel time on changeable-message signs and incident detection, have been gaining popularity in recent years as a source for real-time traffic information to driver operations and transportation systems management and operations. Efforts have been made to evaluate the quality of such data from different perspectives. Although such crowdsourced data are already in widespread use in many states, particularly the high traffic areas on the Eastern seaboard, concerns about latency - the time between traffic being perturbed as a result of an incident and reflection of the disturbance in the outsourced data feed - have escalated in importance. Latency is critical for the accuracy of real-time operations, emergency response, and traveler information systems. This paper offers a methodology for measuring probe data latency regarding a selected reference source. Although Bluetooth reidentification data are used as the reference source, the methodology can be applied to any other ground truth data source of choice. The core of the methodology is an algorithm for maximum pattern matching that works with three fitness objectives. To test the methodology, sample field reference data were collected on multiple freeway segments for a 2-week period by using portable Bluetooth sensors as ground truth. Equivalent GPS probe data were obtained from a private vendor, and their latency was evaluated. Latency at different times of the day, impact of road segmentation scheme on latency, and sensitivity of the latency to both speed-slowdown and recovery-from-slowdown episodes are also discussed.

  7. Comparison of polycrystalline Cu(In,Ga)Se2 device efficiency with junction depth and interfacial structure

    International Nuclear Information System (INIS)

    Nelson, A.J.; Gabor, A.M.; Contreras, M.A.; Tuttle, J.R.; Noufi, R.; Sobol, P.E.; Asoka-Kumar, P.; Lynn, K.G.

    1995-01-01

    X-ray photoemission spectroscopy (XPS) and positron annihilation spectroscopy (PAS) have been used to characterize the surface versus bulk composition, electronic, and physical structure of polycrystalline Cu(In,Ga)Se 2 thin-film interfaces. Angle-resolved high-resolution photoemission measurements on the valence-band electronic structure and Cu 2p, In 3d, Ga 2p, and Se 3d core lines were used to evaluate the surface and near surface chemistry of CuInSe 2 and Cu(In,Ga)Se 2 device grade thin films. XPS compositional depth profiles were also acquired from the near surface region. PAS was used as a nondestructive, depth-sensitive probe for open-volume-type defects. Results of these measurements are related to device efficiencies to show the effects of compositional variations and defect concentrations in the near surface region on device performance. copyright 1995 American Institute of Physics

  8. Development of conductivity probe and temperature probe for in-situ measurements in hydrological studies

    International Nuclear Information System (INIS)

    Chandra, U.; Galindo, B.J.; Castagnet, A.C.G.

    1981-05-01

    A conductivity probe and a temperature probe have been developed for in-situ measurements in various hydrological field studies. The conductivity probe has platinum electrodes and is powered with two 12 volt batteries. The sensing element of the temperature probe consists of a resistor of high coefficient of temperature. Response of the conductivity probe is measured in a milliampere mater while the resistance of the thermistor is read by a digital meter. The values of conductivity and temperature are derived from respective calibration. The probes are prototype and their range of measurement can be improved depending upon the requirement of the field problem. (Author) [pt

  9. Reactions on catalytic probe surface during oxygen plasma treatment of polyether sulphone: Reakcije na površini katalitične sonde med plazemsko obdelavo polieter sulfona:

    OpenAIRE

    Mozetič, Miran

    1998-01-01

    Experiments on the behavior of a nickel catalytic probe during activation of the surface of polyether sulphone in oxygen plasma are described. The temperature of the probe mounted 30 cm apart from inductively coupled RF oxygen plasma was measured for the case of empty dischaarge vessel and the case a sample with the dimensions of 8 cm x 1.2 cm x 0.4 cm was mounted in the middle of the discharge coil. It was found that both the maximum temperature and the first time derivative of the probe was...

  10. Sediment mixing and accumulation rate effects on radionuclide depth profiles in Hudson estuary sediments

    International Nuclear Information System (INIS)

    Olsen, C.R.; Simpson, H.J.; Peng, T.; Bopp, R.F.; Trier, R.M.

    1981-01-01

    Measured anthropogenic radionuclide profiles in sediment cores from the Hudson River estuary were compared with profiles computed by using known input histories of radionuclides to the estuary and mixing coefficients which decreased exponentially with depth in the sediment. Observed 134 Cs sediment depth profiles were used in the mixing rate computation because reactor releases were the only significant source for this nuclide, whereas the inputs of 137 Cs and /sup 239.240/Pu to the estuary were complicated by runoff or erosion in upstream areas, in addition to direct fallout from precipitation. Our estimates for the rates of surface sediment mixing in the low salinity reach of the estuary range from 0.25 to 1 cm 2 /yr, or less. In some areas of the harbor adjacent to New York City, were fine-particle accumulation rates are generally >3 cm/yr, and often as high as 10 to 20 cm/yr, sediment mixing rates as high as 10 cm 2 /yr would have little effect on radionuclide peak distributions. Consequently, anthropogenic radionuclide maximum activities in subsurface sediments of the Hudson appear to be useful as time-stratigraphic reference levels, which can be correlated with periods of maximum radionuclide inputs for estimating rates and patterns of sediment accumulation

  11. Laser-heated emissive plasma probe.

    Science.gov (United States)

    Schrittwieser, Roman; Ionita, Codrina; Balan, Petru; Gstrein, Ramona; Grulke, Olaf; Windisch, Thomas; Brandt, Christian; Klinger, Thomas; Madani, Ramin; Amarandei, George; Sarma, Arun K

    2008-08-01

    Emissive probes are standard tools in laboratory plasmas for the direct determination of the plasma potential. Usually they consist of a loop of refractory wire heated by an electric current until sufficient electron emission. Recently emissive probes were used also for measuring the radial fluctuation-induced particle flux and other essential parameters of edge turbulence in magnetized toroidal hot plasmas [R. Schrittwieser et al., Plasma Phys. Controlled Fusion 50, 055004 (2008)]. We have developed and investigated various types of emissive probes, which were heated by a focused infrared laser beam. Such a probe has several advantages: higher probe temperature without evaporation or melting and thus higher emissivity and longer lifetime, no deformation of the probe in a magnetic field, no potential drop along the probe wire, and faster time response. The probes are heated by an infrared diode laser with 808 nm wavelength and an output power up to 50 W. One probe was mounted together with the lens system on a radially movable probe shaft, and radial profiles of the plasma potential and of its oscillations were measured in a linear helicon discharge.

  12. Laser-heated emissive plasma probe

    International Nuclear Information System (INIS)

    Schrittwieser, Roman; Ionita, Codrina; Balan, Petru; Gstrein, Ramona; Grulke, Olaf; Windisch, Thomas; Brandt, Christian; Klinger, Thomas; Madani, Ramin; Amarandei, George; Sarma, Arun K.

    2008-01-01

    Emissive probes are standard tools in laboratory plasmas for the direct determination of the plasma potential. Usually they consist of a loop of refractory wire heated by an electric current until sufficient electron emission. Recently emissive probes were used also for measuring the radial fluctuation-induced particle flux and other essential parameters of edge turbulence in magnetized toroidal hot plasmas [R. Schrittwieser et al., Plasma Phys. Controlled Fusion 50, 055004 (2008)]. We have developed and investigated various types of emissive probes, which were heated by a focused infrared laser beam. Such a probe has several advantages: higher probe temperature without evaporation or melting and thus higher emissivity and longer lifetime, no deformation of the probe in a magnetic field, no potential drop along the probe wire, and faster time response. The probes are heated by an infrared diode laser with 808 nm wavelength and an output power up to 50 W. One probe was mounted together with the lens system on a radially movable probe shaft, and radial profiles of the plasma potential and of its oscillations were measured in a linear helicon discharge

  13. Laser-heated emissive plasma probe

    Science.gov (United States)

    Schrittwieser, Roman; Ionita, Codrina; Balan, Petru; Gstrein, Ramona; Grulke, Olaf; Windisch, Thomas; Brandt, Christian; Klinger, Thomas; Madani, Ramin; Amarandei, George; Sarma, Arun K.

    2008-08-01

    Emissive probes are standard tools in laboratory plasmas for the direct determination of the plasma potential. Usually they consist of a loop of refractory wire heated by an electric current until sufficient electron emission. Recently emissive probes were used also for measuring the radial fluctuation-induced particle flux and other essential parameters of edge turbulence in magnetized toroidal hot plasmas [R. Schrittwieser et al., Plasma Phys. Controlled Fusion 50, 055004 (2008)]. We have developed and investigated various types of emissive probes, which were heated by a focused infrared laser beam. Such a probe has several advantages: higher probe temperature without evaporation or melting and thus higher emissivity and longer lifetime, no deformation of the probe in a magnetic field, no potential drop along the probe wire, and faster time response. The probes are heated by an infrared diode laser with 808nm wavelength and an output power up to 50W. One probe was mounted together with the lens system on a radially movable probe shaft, and radial profiles of the plasma potential and of its oscillations were measured in a linear helicon discharge.

  14. The photosynthetic responses to stocking depth and algal mat density in the farmed seaweed Gracilaria lemaneiformis (Gracilariales, Rhodophyta).

    Science.gov (United States)

    Jiang, Heng; Zou, Dinghui; Chen, Weizhou; Yang, Yufeng

    2017-11-01

    The branches and mass of Gracilaria lemaneiformis increase with growth season, and the thalli sink to deeper depths with increasing biomass density during maricultivation. The changing depth and algal mat density may affect the physiology of the algae. In the present study, the photosynthetic behaviors regarding different biomass densities in G. lemaneiformis thalli collected from different stocking depths were determined, to examine how photosynthesis of this farmed alga was affected by the growth depths and algal mat densities. Our results showed that the chlorophyll a (Chl a), carotenoids (Car), phycoerythrin (PE) contents, and irradiance-saturated maximum photosynthetic rates (P max ) of the deeper layer-grown algae were significantly increased relative to the surface layer-grown algae. The P max , apparent photosynthetic efficiency (α) and dark respiration rate (R d ) of G. lemaneiformis thalli, were reduced, whereas the irradiance saturation points (I k ) were increased, with the increasing algal mat density. We proposed that appropriate measures are needed to trade off the stocking depth and biomass density, in an effort to maintain a relative high photosynthetic productivity during G. lemaneiformis maricultivation.

  15. Search for the maximum efficiency of a ribbed-surfaces device, providing a tight seal

    International Nuclear Information System (INIS)

    Boutin, Jeanne.

    1977-04-01

    The purpose of this experiment was to determine the geometrical characteristics of ribbed surfaces used to equip devices in translation or slow rotation motion and having to form an acceptable seal between slightly viscous fluids. It systematically studies the pressure loss coefficient lambda in function of the different parameters setting the form of ribs and their relative position on the opposite sides. It shows that the passages with two ribbed surfaces lead to highly better results than those with only one, the maximum value of lambda, equal to 0.5, being obtained with the ratios: pitch/clearance = 5, depth of groove/clearance = 1,2, and with their teeth face to face on the two opposite ribbed surfaces. With certain shapes, alternate position of ribs can lead to the maximum of lambda yet lower than 0.5 [fr

  16. Silver nanowires for highly reproducible cantilever based AFM-TERS microscopy: towards a universal TERS probe.

    Science.gov (United States)

    Walke, Peter; Fujita, Yasuhiko; Peeters, Wannes; Toyouchi, Shuichi; Frederickx, Wout; De Feyter, Steven; Uji-I, Hiroshi

    2018-04-26

    Tip-enhanced Raman scattering (TERS) microscopy is a unique analytical tool to provide complementary chemical and topographic information of surfaces with nanometric resolution. However, difficulties in reliably producing the necessary metallized scanning probe tips has limited its widespread utilisation, particularly in the case of cantilever-based atomic force microscopy. Attempts to alleviate tip related issues using colloidal or bottom-up engineered tips have so far not reported consistent probes for both Raman and topographic imaging. Here we demonstrate the reproducible fabrication of cantilever-based high-performance TERS probes for both topographic and Raman measurements, based on an approach that utilises noble metal nanowires as the active TERS probe. The tips show 10 times higher TERS contrasts than the most typically used electrochemically-etched tips, and show a reproducibility for TERS greater than 90%, far greater than found with standard methods. We show that TERS can be performed in tapping as well as contact AFM mode, with optical resolutions around or below 15 nm, and with a maximum resolution achieved in tapping-mode of 6 nm. Our work illustrates that superior TERS probes can be produced in a fast and cost-effective manner using simple wet-chemistry methods, leading to reliable and reproducible high-resolution and high-sensitivity TERS, and thus renders the technique applicable for a broad community.

  17. Innovative SPM Probes for Energy-Storage Science: MWCNT-Nanopipettes to Nanobattery Probes

    Science.gov (United States)

    Larson, Jonathan; Talin, Alec; Pearse, Alexander; Kozen, Alexander; Reutt-Robey, Janice

    As energy-storage materials and designs continue to advance, new tools are needed to direct and explore ion insertion/de-insertion at well-defined battery materials interfaces. Scanned probe tips, assembled from actual energy-storage materials, permit SPM measures of local cathode-anode (tip-sample) interactions, including ion transfer. We present examples of ``cathode'' MWCNT-terminated STM probe tips interacting with Li(s)/Si(111) anode substrates. The MWCNT tip functions as both SPM probe and Li-nanopipette,[1] for controlled transport and manipulation of Li. Local field conditions for lithium ionization and transfer are determined and compared to electrostatic models. Additional lithium metallic and oxide tips have been prepared by thin film deposition on conventional W tips, the latter of which effectively functions as a nanobattery. We demonstrate use of these novel probe materials in the local lithiation of low-index Si anode interfaces, probing local barriers for lithium insertion. Prospects and limitations of these novel SPM probes will be discussed. U.S. Department of Energy Award Number DESC0001160.

  18. Geothermal long-term modelling of a solar coupled geothermal probe heat storage in Crailsheim; Geothermische Langzeitmodellierung eines solargekoppelten Erdsonden-Waermespeichers in Crailsheim

    Energy Technology Data Exchange (ETDEWEB)

    Homuth, Sebastian; Mikisek, Philipp; Goetz, Annette E.; Sass, Ingo [Technische Univ. Darmstadt (Germany). Fachgebiet Angewandte Geothermie

    2011-10-24

    The thermal variations of the subsurface in the vicinity of a seasonal solar coupled geothermal probe heat storage were modeled using FEFLOW {sup registered} over a period of thirty years. The geothermal probe heat storage consists of eighty boreholes in an area of 85 square meters. The geothermal probes have a depth of 55 m and are mainly located in limestones of the Upper Muschelkalk (Triassic). The geothermal probe heat storage is thermally loaded from April to September. The thermal discharge takes place from October to March. The thermal and hydraulic input data of the model are based on three 80 meter deep geothermal probes (GWM 1-3) in the vicinity of the storage. The cores were completely lithologically, facially and finely stratigraphically affiliated. Measurements of thermal conductivity, permeability, porosity and density of 76 representative samples from the geothermal probe GWM 3 and measurements of the main fracture directions in two reference digestions at Crailsheim enabled a most realistic modeling of the storage. The results of the long-term modeling can be used for a detailed forecasting of the thermal alterations in the subsurface.

  19. Profiling water content in soils with TDR: Comparison with the neutron probe technique

    International Nuclear Information System (INIS)

    Laurent, J.P.

    2000-01-01

    In November 1996, at a site on the Grenoble campus a 1.2-m-long neutron access tube, a 0.8-m fibreglass Trime access tube and three sets of 1-m twin-rod TDR probes were installed. Weekly measurements were made over a 9-month period. In addition, soil samples were taken from time to time with an auger, to determine gravimetric water-contents. The soil bulk density profile was initially characterised by gammametry using a Campbell TM probe. A Troxler TM 4300 was used for the neutron-probe measurements. The TDR signals, for further processing by TDR-SSI, were logged using a Trase 2000 from Soil Moisture Equipment Corporation TM . TDR methods were employed without any special calibration of the permittivity/water-content relationship: standard internal calibrations of the devices or Topp polynomial relation were always applied. The results of all these water-content profiling methods were compared in three ways: (i) the water-content profiles were plotted directly on the same graph for different dates; (ii) all the water contents measured at all dates and all depths were plotted against a corresponding 'reference', namely neutron probe or gravimetry; (iii) water balances were calculated for each method and their respective time-profiles analysed. There was fairly good agreement among the three profiling methods, indicating that TDR is now a viable alternative to nuclear techniques for soil water-content profiling. (author)

  20. Object-based spatial attention when objects have sufficient depth cues.

    Science.gov (United States)

    Takeya, Ryuji; Kasai, Tetsuko

    2015-01-01

    Attention directed to a part of an object tends to obligatorily spread over all of the spatial regions that belong to the object, which may be critical for rapid object-recognition in cluttered visual scenes. Previous studies have generally used simple rectangles as objects and have shown that attention spreading is reflected by amplitude modulation in the posterior N1 component (150-200 ms poststimulus) of event-related potentials, while other interpretations (i.e., rectangular holes) may arise implicitly in early visual processing stages. By using modified Kanizsa-type stimuli that provided less ambiguity of depth ordering, the present study examined early event-related potential spatial-attention effects for connected and separated objects, both of which were perceived in front of (Experiment 1) and in back of (Experiment 2) the surroundings. Typical P1 (100-140 ms) and N1 (150-220 ms) attention effects of ERP in response to unilateral probes were observed in both experiments. Importantly, the P1 attention effect was decreased for connected objects compared to separated objects only in Experiment 1, and the typical object-based modulations of N1 were not observed in either experiment. These results suggest that spatial attention spreads over a figural object at earlier stages of processing than previously indicated, in three-dimensional visual scenes with multiple depth cues.

  1. Theory of NMR probe design

    International Nuclear Information System (INIS)

    Schnall, M.D.

    1988-01-01

    The NMR probe is the intrinsic part of the NMR system which allows transmission of a stimulus to a sample and the reception of a resulting signal from a sample. NMR probes are used in both imaging and spectroscopy. Optimal probe design is important to the production of adequate signal/moise. It is important for anyone using NMR techniques to understand how NMR probes work and how to optimize probe design

  2. Comparison of experimental and theoretical depth doses in the ICRU sphere using 137Cs

    International Nuclear Information System (INIS)

    Williams, G.; Jankowski, J.; Swanson, W.P.; Drexler, G.

    1985-01-01

    To confirm the theoretical model used at the Gesellschaft fuer Strahlen- and Umweltforschung, mbH (GSF) to calculate photon depth-dose distributions in the International Commission on Radiological Units and Measurements (ICRU) sphere, an experiment was performed using 137 Cs (662 keV). Measurements were made for a unidirectional parallel beam and for planar-isotropic irradiation. The theory predicts that, for photons of this energy, the maximum dose occurs at the equator of the sphere, when a broad unidirectional parallel beam is incident along the polar (central) axis. The energy of photons from 137 Cs is well suited for a test of this sort because the ratio of equatorial maximum to central-axis maximum appears to have a broad maximum itself at about this energy. In the theory, charged particle equilibrium (CPE) is assumed and the kerma approximation is applied. It is possible that the degree to which CPE is attained affects the outcome, especially at the equator, but if sufficient charge-build-up occurs in the air at the sphere surface then the kerma approximation is acceptable and the calculated distributions should be closely representative of the absorbed-dose distributions

  3. Polarimetry of SN 2014J in M82 as a Probe of Its Dusty Environment

    Science.gov (United States)

    Wang, Lifan

    2014-10-01

    Late time polarimetry can effectively probe the circumstellar (CS) dust environment of SNe Ia. We propose to acquire imaging polarimetry of SN 2014J at three epochs between 200-400 days after the SN explosion. The delayed light from optical maximum may be scattered into the line of sight and reveal the scattering dust through polarization. Light echoes from interstellar dust at very large distances (> 10pc) from the SN will not be highly polarized in these observations due to the small scattering angle involved. Polarimetry at late time is thus an unambegeous probe of CS dust very close to the SN (at distances ~ 1 light year). Observations of the illusive CS matter is critical in constraining the progenitor systems of SNIa.

  4. Coronal in vivo forward-imaging of rat brain morphology with an ultra-small optical coherence tomography fiber probe

    Science.gov (United States)

    Xie, Yijing; Bonin, Tim; Löffler, Susanne; Hüttmann, Gereon; Tronnier, Volker; Hofmann, Ulrich G.

    2013-02-01

    A well-established navigation method is one of the key conditions for successful brain surgery: it should be accurate, safe and online operable. Recent research shows that optical coherence tomography (OCT) is a potential solution for this application by providing a high resolution and small probe dimension. In this study a fiber-based spectral-domain OCT system utilizing a super-luminescent-diode with the center wavelength of 840 nm providing 14.5 μm axial resolution was used. A composite 125 μm diameter detecting probe with a gradient index (GRIN) fiber fused to a single mode fiber was employed. Signals were reconstructed into grayscale images by horizontally aligning A-scans from the same trajectory with different depths. The reconstructed images can display brain morphology along the entire trajectory. For scans of typical white matter, the signals showed a higher reflection of light intensity with lower penetration depth as well as a steeper attenuation rate compared to the scans typical for gray matter. Micro-structures such as axon bundles (70 μm) in the caudate nucleus are visible in the reconstructed images. This study explores the potential of OCT to be a navigation modality in brain surgery.

  5. {sup 3}He spectrum at small atmospheric depths for different geomagnetic cutoff values

    Energy Technology Data Exchange (ETDEWEB)

    Papini, P. [Florence Univ. (Italy)]|[INFN, Florence (Italy); Grimani, C. [Perugia Univ. (Italy)]|[INFN, Perugia (Italy); Stephens, S.A. [Tata Institute of Fundamental Research, Bombay (International Commission on Radiation Units and Measurements)

    1995-09-01

    It is carried out a calculation to determine the energy spectra of secondary {sup 3}He at small atmospheric depths. It is produced in the spallation reaction of primary helium and heavier nuclei in the overlying atmosphere. It is examined the effect of the geomagnetic cut-off on the spectral shape of the secondary {sup 3}He nuclei. The calculations are being carried out for both solar minimum and maximum periods. Results from these calculations will be presented at the Conference.

  6. Cultural probes

    DEFF Research Database (Denmark)

    Madsen, Jacob Østergaard

    The aim of this study was thus to explore cultural probes (Gaver, Boucher et al. 2004), as a possible methodical approach, supporting knowledge production on situated and contextual aspects of occupation.......The aim of this study was thus to explore cultural probes (Gaver, Boucher et al. 2004), as a possible methodical approach, supporting knowledge production on situated and contextual aspects of occupation....

  7. Effect of Sleeve Plunge Depth on Microstructure and Mechanical Properties of Refill Friction Stir Spot Welding of 2198 Aluminum Alloy

    Science.gov (United States)

    Yue, Yumei; Shi, Yao; Ji, Shude; Wang, Yue; Li, Zhengwei

    2017-10-01

    Refill friction stir spot welding (RFSSW) is a new spot welding technology, by which spot joint without keyhole can be obtained. In this work, RFSSW was used to join 2-mm-thick 2198-T8 aluminum alloy sheets and effects of the sleeve plunge depth on microstructure and lap shear properties of the joints were mainly discussed. Results showed that when using small plunge depths of 2.4 and 2.6 mm, joints showed good formation and no defects were observed. Incomplete refilling defect was observed with increasing plunge depth due to material loss during welding. Size of the grains at sleeve-affected zone (SAZ) is smaller than that at the pin-affected zone, and the size becomes bigger with increasing the plunge depth. More secondary phase particles can be observed at SAZ with increasing the sleeve plunge depth. The lap shear failure load firstly increased and then decreased with increasing the sleeve plunge depth. The maximum failure load of 9819 N was attained with plug fracture mode when using 2.6 mm. Fracture morphologies show ductile fracture mode.

  8. Multiscale analysis of depth-dependent soil penetration resistance in a tropical soil

    Science.gov (United States)

    Paiva De Lima, Renato; Santos, Djail; Medeiros Bezerra, Joel; Machado Siqueira, Glécio; Paz González, Antonio

    2013-04-01

    Soil penetration resistance (PR) is widely used because it is linked to basic soil properties; it is correlated to root growth and plant production and is also used as a practical tool for assessing soil compaction and to evaluate the effects of soil management. This study investigates how results from multifractal analysis can quantify key elements of depth-dependent PR profiles and how this information can be used at the field scale. We analyzed multifractality of 50 PR vertical profiles, measured from 0 to 40 cm depth and randomly located on a 6.5 ha sugar cane field in north-eastern Brazil. According to the Soil Taxonomy, the studied soil was classified as an Orthic Podsol The scaling property of each profile was typified by singularity and Rényi spectra estimated by the method of moments. The Hurst exponent was used to parameterize the autocorrelation of the vertical PR data sets. Singularity and Rènyi spectra showed the vertical PR data sets exhibited a well-defined multifractal structure. Hurst exponent values were close to one indicating strong persistence in PR variation with soil depth. Also Hurst exponent was negatively and significantly correlated to coefficient of variation (CV) and skewness of the depth-dependent PR. Multifractal analysis added valuable information to describe the spatial arrangement of depth-dependent penetrometer data sets, which was not taken into account by classical statistical indices. Multifractal parameters were mapped over the experimental field and compared with mean, maximum and minimum values of PR; these maps showed the multifractal approach also may complete information provided by descriptive statistics at the field scale.

  9. Organic liquids-responsive β-cyclodextrin-functionalized graphene-based fluorescence probe: label-free selective detection of tetrahydrofuran.

    Science.gov (United States)

    Hu, Huawen; Xin, John H; Hu, Hong; Wang, Xiaowen; Lu, Xinkun

    2014-06-06

    In this study, a label-free graphene-based fluorescence probe used for detection of volatile organic liquids was fabricated by a simple, efficient and low-cost method. To fabricate the probe, a bio-based β-cyclodextrin (β-CD) was firstly grafted on reduced graphene surfaces effectively and uniformly, as evidenced by various characterization techniques such as Ultraviolet/Visible spectroscopy, Fourier transform infrared spectroscopy, X-ray diffraction, thermogravimetric analysis, scanning electron microscopy and transmission electron microscopy. The subsequent inclusion of Rhodamine B (RhB) into the inner cavities of the β-CD grafted on the graphene surfaces was achieved easily by a solution mixing method, which yielded the graphene-based fluorescent switch-on probe. In addition, the gradual and controllable quenching of RhB by Fluorescence Resonance Energy Transfer from RhB to graphene during the process of stepwise accommodation of the RhB molecules into the β-CD-functionalized graphene was investigated in depth. A wide range of organic solvents was examined using the as-fabricated fluorescence probe, which revealed the highest sensitivity to tetrahydrofuran with the detection limit of about 1.7 μg/mL. Some insight into the mechanism of the different responsive behaviors of the fluorescence sensor to the examined targets was also described.

  10. Organic Liquids-Responsive β-Cyclodextrin-Functionalized Graphene-Based Fluorescence Probe: Label-Free Selective Detection of Tetrahydrofuran

    Directory of Open Access Journals (Sweden)

    Huawen Hu

    2014-06-01

    Full Text Available In this study, a label-free graphene-based fluorescence probe used for detection of volatile organic liquids was fabricated by a simple, efficient and low-cost method. To fabricate the probe, a bio-based β-cyclodextrin (β-CD was firstly grafted on reduced graphene surfaces effectively and uniformly, as evidenced by various characterization techniques such as Ultraviolet/Visible spectroscopy, Fourier transform infrared spectroscopy, X-ray diffraction, thermogravimetric analysis, scanning electron microscopy and transmission electron microscopy. The subsequent inclusion of Rhodamine B (RhB into the inner cavities of the β-CD grafted on the graphene surfaces was achieved easily by a solution mixing method, which yielded the graphene-based fluorescent switch-on probe. In addition, the gradual and controllable quenching of RhB by Fluorescence Resonance Energy Transfer from RhB to graphene during the process of stepwise accommodation of the RhB molecules into the β-CD-functionalized graphene was investigated in depth. A wide range of organic solvents was examined using the as-fabricated fluorescence probe, which revealed the highest sensitivity to tetrahydrofuran with the detection limit of about 1.7 μg/mL. Some insight into the mechanism of the different responsive behaviors of the fluorescence sensor to the examined targets was also described.

  11. Effect of the depth base along the vertical on the electrical parameters of a vertical parallel silicon solar cell in open and short circuit

    Directory of Open Access Journals (Sweden)

    Gokhan Sahin

    2018-03-01

    Full Text Available This article presented a modeling study of effect of the depth base initiating on vertical parallel silicon solar cell’s photovoltaic conversion efficiency. After the resolution of the continuity equation of excess minority carriers, we calculated the electrical parameters such as the photocurrent density, the photovoltage, series resistance and shunt resistances, diffusion capacitance, electric power, fill factor and the photovoltaic conversion efficiency. We determined the maximum electric power, the operating point of the solar cell and photovoltaic conversion efficiency according to the depth z in the base. We showed that the photocurrent density decreases with the depth z. The photovoltage decreased when the depth base increases. Series and shunt resistances were deduced from electrical model and were influenced and the applied the depth base. The capacity decreased with the depth z of the base. We had studied the influence of the variation of the depth z on the electrical parameters in the base. Keywords: Depth base, Conversion efficiency, Electrical parameters, Open circuit, Short circuit

  12. Construction of an efficient two-photon fluorescent probe for imaging nitroreductase in live cells and tissues

    Science.gov (United States)

    Zhou, Liyi; Gong, Liang; Hu, Shunqin

    2018-06-01

    Compared with traditional confocal microscopy, two-photon fluorescence microscopy (TPFM), which excites a two-photon (TP) fluorophore by near-infrared light, provides improved three-dimensional image resolution with increased tissue-image depth (>500 μm) and an extended observation time. Therefore, the development of novel functional TP fluorophores has attracted great attention in recent years. Herein, a novel TP fluorophore CM-NH2, which have the donor-π-acceptor (D-π-A)-structure, was designed and synthesized. We further used this dye developed a new type of TP fluorescent probe CM-NO2 for detecting nitroreductase (NTR). Upon incubated with NTR for 15 min, CM-NO2 displayed a 90-fold fluorescence enhancement at 505 nm and the maximal TP action cross-section value after reaction was detected and calculated to be 200 GM at 760 nm. The probe exhibited excellent properties such as high sensitivity, high selectivity, low cytotoxicity, and high photostability. Moreover, the probe was utilized to image the tumor hypoxia in live HeLa cells. Finally, using the CM-NO2 to image NTR in tissues was demonstrated.

  13. Proposal of evaluation method of tsunami wave pressure using 2D depth-integrated flow simulation

    International Nuclear Information System (INIS)

    Arimitsu, Tsuyoshi; Ooe, Kazuya; Kawasaki, Koji

    2012-01-01

    To design and construct land structures resistive to tsunami force, it is most essential to evaluate tsunami pressure quantitatively. The existing hydrostatic formula, in general, tended to underestimate tsunami wave pressure under the condition of inundation flow with large Froude number. Estimation method of tsunami pressure acting on a land structure was proposed using inundation depth and horizontal velocity at the front of the structure, which were calculated employing a 2D depth-integrated flow model based on the unstructured grid system. The comparison between the numerical and experimental results revealed that the proposed method could reasonably reproduce the vertical distribution of the maximum tsunami pressure as well as the time variation of the tsunami pressure exerting on the structure. (author)

  14. All-optical in-depth detection of the acoustic wave emitted by a single gold nanorod

    Science.gov (United States)

    Xu, Feng; Guillet, Yannick; Ravaine, Serge; Audoin, Bertrand

    2018-04-01

    A single gold nanorod dropped on the surface of a silica substrate is used as a transient optoacoustic source of gigahertz hypersounds. We demonstrate the all-optical detection of the as-generated acoustic wave front propagating in the silica substrate. For this purpose, time-resolved femtosecond pump-probe experiments are performed in a reflection configuration. The fundamental breathing mode of the nanorod is detected at 23 GHz by interferometry, and the longitudinal acoustic wave radiated in the silica substrate is detected by time-resolved Brillouin scattering. By tuning the optical probe wavelength from 750 to 900 nm, hypersounds with wavelengths of 260-315 nm are detected in the silica substrate, with corresponding acoustic frequencies in the range of 19-23 GHz. To confirm the origin of these hypersounds, we theoretically analyze the influence of the acoustic excitation spectrum on the temporal envelope of the transient reflectivity. This analysis proves that the acoustic wave detected in the silica substrate results from the excitation of the breathing mode of the nanorod. These results pave the way for performing local in-depth elastic nanoscopy.

  15. Imaging of Fluoride Ion in Living Cells and Tissues with a Two-Photon Ratiometric Fluorescence Probe

    Directory of Open Access Journals (Sweden)

    Xinyue Zhu

    2015-01-01

    Full Text Available A reaction-based two-photon (TP ratiometric fluorescence probe Z2 has been developed and successfully applied to detect and image fluoride ion in living cells and tissues. The Z2 probe was designed designed to utilize an ICT mechanism between n-butylnaphthalimide as a fluorophore and tert-butyldiphenylsilane (TBDPS as a response group. Upon addition of fluoride ion, the Si-O bond in the Z2 would be cleaved, and then a stronger electron-donating group was released. The fluorescent changes at 450 and 540 nm, respectively, made it possible to achieve ratiometric fluorescence detection. The results indicated that the Z2 could ratiometrically detect and image fluoride ion in living cells and tissues in a depth of 250 μm by two-photon microscopy (TPM.

  16. Discrete Model Predictive Control-Based Maximum Power Point Tracking for PV Systems: Overview and Evaluation

    DEFF Research Database (Denmark)

    Lashab, Abderezak; Sera, Dezso; Guerrero, Josep M.

    2018-01-01

    The main objective of this work is to provide an overview and evaluation of discrete model predictive controlbased maximum power point tracking (MPPT) for PV systems. A large number of MPC based MPPT methods have been recently introduced in the literature with very promising performance, however......, an in-depth investigation and comparison of these methods have not been carried out yet. Therefore, this paper has set out to provide an in-depth analysis and evaluation of MPC based MPPT methods applied to various common power converter topologies. The performance of MPC based MPPT is directly linked...... with the converter topology, and it is also affected by the accurate determination of the converter parameters, sensitivity to converter parameter variations is also investigated. The static and dynamic performance of the trackers are assessed according to the EN 50530 standard, using detailed simulation models...

  17. Selective and Sensitive Detection of Cyanide Based on the Displacement Strategy Using a Water-Soluble Fluorescent Probe

    Science.gov (United States)

    La, Ming; Hao, Yuanqiang; Wang, Zhaoyang; Han, Guo-Cheng; Qu, Lingbo

    2016-01-01

    A water-soluble fluorescent probe (C-GGH) was used for the highly sensitive and selective detection of cyanide (CN−) in aqueous media based on the displacement strategy. Due to the presence of the recognition unit GGH (Gly-Gly-His), the probe C-GGH can coordinate with Cu2+ and consequently display ON-OFF type fluorescence response. Furthermore, the in situ formed nonfluorescent C-GGH-Cu2+ complex can act as an effective OFF-ON type fluorescent probe for sensing CN− anion. Due to the strong binding affinity of CN− to Cu2+, CN− can extract Cu2+ from C-GGH-Cu2+ complex, leading to the release of C-GGH and the recovery of fluorescent emission of the system. The probe C-GGH-Cu2+ allowed detection of CN− in aqueous solution with a LOD (limit of detection) of 0.017 μmol/L which is much lower than the maximum contaminant level (1.9 μmol/L) for CN− in drinking water set by the WHO (World Health Organization). The probe also displayed excellent specificity for CN− towards other anions, including F−, Cl−, Br−, I−, SCN−, PO4 3−, N3 −, NO3 −, AcO−, SO4 2−, and CO3 2−. PMID:26881185

  18. Selective and Sensitive Detection of Cyanide Based on the Displacement Strategy Using a Water-Soluble Fluorescent Probe

    Directory of Open Access Journals (Sweden)

    Ming La

    2016-01-01

    Full Text Available A water-soluble fluorescent probe (C-GGH was used for the highly sensitive and selective detection of cyanide (CN− in aqueous media based on the displacement strategy. Due to the presence of the recognition unit GGH (Gly-Gly-His, the probe C-GGH can coordinate with Cu2+ and consequently display ON-OFF type fluorescence response. Furthermore, the in situ formed nonfluorescent C-GGH-Cu2+ complex can act as an effective OFF-ON type fluorescent probe for sensing CN− anion. Due to the strong binding affinity of CN− to Cu2+, CN− can extract Cu2+ from C-GGH-Cu2+ complex, leading to the release of C-GGH and the recovery of fluorescent emission of the system. The probe C-GGH-Cu2+ allowed detection of CN− in aqueous solution with a LOD (limit of detection of 0.017 μmol/L which is much lower than the maximum contaminant level (1.9 μmol/L for CN− in drinking water set by the WHO (World Health Organization. The probe also displayed excellent specificity for CN− towards other anions, including F−, Cl−, Br−, I−, SCN−, PO43-, N3-, NO3-, AcO−, SO42-, and CO32-.

  19. Dual-probe decoherence microscopy: probing pockets of coherence in a decohering environment

    International Nuclear Information System (INIS)

    Jeske, Jan; Cole, Jared H; Müller, Clemens; Marthaler, Michael; Schön, Gerd

    2012-01-01

    We study the use of a pair of qubits as a decoherence probe of a nontrivial environment. This dual-probe configuration is modelled by three two-level systems (TLSs), which are coupled in a chain in which the middle system represents an environmental TLS. This TLS resides within the environment of the qubits and therefore its coupling to perturbing fluctuations (i.e. its decoherence) is assumed much stronger than the decoherence acting on the probe qubits. We study the evolution of such a tripartite system including the appearance of a decoherence-free state (dark state) and non-Markovian behaviour. We find that all parameters of this TLS can be obtained from measurements of one of the probe qubits. Furthermore, we show the advantages of two qubits in probing environments and the new dynamics imposed by a TLS that couples to two qubits at once. (paper)

  20. A new method for depth profiling reconstruction in confocal microscopy

    Science.gov (United States)

    Esposito, Rosario; Scherillo, Giuseppe; Mensitieri, Giuseppe

    2018-05-01

    Confocal microscopy is commonly used to reconstruct depth profiles of chemical species in multicomponent systems and to image nuclear and cellular details in human tissues via image intensity measurements of optical sections. However, the performance of this technique is reduced by inherent effects related to wave diffraction phenomena, refractive index mismatch and finite beam spot size. All these effects distort the optical wave and cause an image to be captured of a small volume around the desired illuminated focal point within the specimen rather than an image of the focal point itself. The size of this small volume increases with depth, thus causing a further loss of resolution and distortion of the profile. Recently, we proposed a theoretical model that accounts for the above wave distortion and allows for a correct reconstruction of the depth profiles for homogeneous samples. In this paper, this theoretical approach has been adapted for describing the profiles measured from non-homogeneous distributions of emitters inside the investigated samples. The intensity image is built by summing the intensities collected from each of the emitters planes belonging to the illuminated volume, weighed by the emitters concentration. The true distribution of the emitters concentration is recovered by a new approach that implements this theoretical model in a numerical algorithm based on the Maximum Entropy Method. Comparisons with experimental data and numerical simulations show that this new approach is able to recover the real unknown concentration distribution from experimental profiles with an accuracy better than 3%.

  1. Optimum soil frost depth to alleviate climate change effects in cold region agriculture.

    Science.gov (United States)

    Yanai, Yosuke; Iwata, Yukiyoshi; Hirota, Tomoyoshi

    2017-03-21

    On-farm soil frost control has been used for the management of volunteer potatoes (Solanum tuberosum L.), a serious weed problem caused by climate change, in northern Japan. Deep soil frost penetration is necessary for the effective eradication of unharvested small potato tubers; however, this process can delay soil thaw and increase soil wetting in spring, thereby delaying agricultural activity initiation and increasing nitrous oxide emissions from soil. Conversely, shallow soil frost development helps over-wintering of unharvested potato tubers and nitrate leaching from surface soil owing to the periodic infiltration of snowmelt water. In this study, we synthesised on-farm snow cover manipulation experiments to determine the optimum soil frost depth that can eradicate unharvested potato tubers without affecting agricultural activity initiation while minimising N pollution from agricultural soil. The optimum soil frost depth was estimated to be 0.28-0.33 m on the basis of the annual maximum soil frost depth. Soil frost control is a promising practice to alleviate climate change effects on agriculture in cold regions, which was initiated by local farmers and further promoted by national and local research institutes.

  2. Optimum soil frost depth to alleviate climate change effects in cold region agriculture

    Science.gov (United States)

    Yanai, Yosuke; Iwata, Yukiyoshi; Hirota, Tomoyoshi

    2017-03-01

    On-farm soil frost control has been used for the management of volunteer potatoes (Solanum tuberosum L.), a serious weed problem caused by climate change, in northern Japan. Deep soil frost penetration is necessary for the effective eradication of unharvested small potato tubers; however, this process can delay soil thaw and increase soil wetting in spring, thereby delaying agricultural activity initiation and increasing nitrous oxide emissions from soil. Conversely, shallow soil frost development helps over-wintering of unharvested potato tubers and nitrate leaching from surface soil owing to the periodic infiltration of snowmelt water. In this study, we synthesised on-farm snow cover manipulation experiments to determine the optimum soil frost depth that can eradicate unharvested potato tubers without affecting agricultural activity initiation while minimising N pollution from agricultural soil. The optimum soil frost depth was estimated to be 0.28-0.33 m on the basis of the annual maximum soil frost depth. Soil frost control is a promising practice to alleviate climate change effects on agriculture in cold regions, which was initiated by local farmers and further promoted by national and local research institutes.

  3. Model for resonant plasma probe.

    Energy Technology Data Exchange (ETDEWEB)

    Warne, Larry Kevin; Johnson, William Arthur; Hebner, Gregory Albert; Jorgenson, Roy E.; Coats, Rebecca Sue

    2007-04-01

    This report constructs simple circuit models for a hairpin shaped resonant plasma probe. Effects of the plasma sheath region surrounding the wires making up the probe are determined. Electromagnetic simulations of the probe are compared to the circuit model results. The perturbing effects of the disc cavity in which the probe operates are also found.

  4. Depth and stratigraphy of regolith. Site descriptive modelling SDM-Site Laxemar

    International Nuclear Information System (INIS)

    Nyman, Helena; Sohlenius, Gustav; Stroemgren, Maarten; Brydsten, Lars

    2008-06-01

    on the geographical distribution of Quaternary deposits. The average regolith depth in each domain was calculated by the use of available data. These average depths were used together with measured depths to interpolate the regolith depths in the model area. The six layers (Z1-Z6) were modelled in the same way. The six layers represent different types of regolith. The uppermost layer, Z1, is influenced by the impact from surface processes, e.g. roots and biological activity. The next layer (Z2) consists of peat. After that follows layer Z3, which is characterised by clay gyttja, followed by layer Z4 that consist of sand/gravel, glaciofluvial sediment or artificial fill. Layer Z5 correspond to glacial clay and the bottom layer Z6 correspond to till, which is resting directly upon the bedrock surface. The resulting model clearly shows the valleys with thick regolith depths, surrounded by higher areas with thin layers of regolith and bedrock outcrops. The glaciofluvial esker (The Tuna esker) is distinctly shown as north-south band with a thick layer of regolith in the western part of the model area. The maximum depth of regolith in the model is about 48 m, and the average depth in this area is 2.2 m with bedrock outcrops included and 3.7 m with outcrops excluded

  5. Depth and stratigraphy of regolith. Site descriptive modelling SDM-Site Laxemar

    Energy Technology Data Exchange (ETDEWEB)

    Nyman, Helena (SWECO Position, Stockholm (Sweden)); Sohlenius, Gustav (Geological Survey of Sweden (SGU), Uppsala (Sweden)); Stroemgren, Maarten; Brydsten, Lars (Umeaa Univ., Umeaa (Sweden))

    2008-06-15

    the geographical distribution of Quaternary deposits. The average regolith depth in each domain was calculated by the use of available data. These average depths were used together with measured depths to interpolate the regolith depths in the model area. The six layers (Z1-Z6) were modelled in the same way. The six layers represent different types of regolith. The uppermost layer, Z1, is influenced by the impact from surface processes, e.g. roots and biological activity. The next layer (Z2) consists of peat. After that follows layer Z3, which is characterised by clay gyttja, followed by layer Z4 that consist of sand/gravel, glaciofluvial sediment or artificial fill. Layer Z5 correspond to glacial clay and the bottom layer Z6 correspond to till, which is resting directly upon the bedrock surface. The resulting model clearly shows the valleys with thick regolith depths, surrounded by higher areas with thin layers of regolith and bedrock outcrops. The glaciofluvial esker (The Tuna esker) is distinctly shown as north-south band with a thick layer of regolith in the western part of the model area. The maximum depth of regolith in the model is about 48 m, and the average depth in this area is 2.2 m with bedrock outcrops included and 3.7 m with outcrops excluded

  6. A convenient colorimetric and ratiometric fluorescent probe for detection of cyanide based on BODIPY derivative in aqueous media

    Directory of Open Access Journals (Sweden)

    Yanhua Yu

    2017-06-01

    Full Text Available A convenient colorimetric and ratiometric fluorescent probe based on BODIPY derivative for cyanide detection has been synthesized, whose structural contains a dicyanovinyl group used as a sensing unit. Among the tested analytes, such as CN−, F−, Cl−, Br−, I−, ClO4−, AcO−, NO3−, H2PO4− HSO4−, S2− and N3−, only CN− could react with dicyanovinyl moiety by nucleophilic addition, which disrupted the π-conjugation of the probe and hindered the intramolecular charge transfer (ICT, leading a blue shift of absorption and fluorescence spectrum and a concomitant color change from yellow to light pink. The detection limit of this probe was calculated to be 0.98 μM, which is lower than the maximum concentration in drinking water (1.9 μM permitted by the World Health Organization (WHO. Moreover, the probe showed excellent selectivity and anti-interference ability towards CN− over other anions. The reaction mechanism was fully supported by 1H NMR and MS spectrum.

  7. Preconditioning of Antarctic maximum sea-ice extent by upper-ocean stratification on a seasonal timescale

    OpenAIRE

    Su, Zhan

    2017-01-01

    This study uses an observationally constrained and dynamically consistent ocean and sea ice state estimate. The author presents a remarkable agreement between the location of the edge of Antarctic maximum sea ice extent, reached in September, and the narrow transition band for the upper ocean (0–100 m depths) stratification, as early as April to June. To the south of this edge, the upper ocean has high stratification, which forbids convective fluxes to cross through; consequently, the ocean h...

  8. Characterization of near-field optical probes

    DEFF Research Database (Denmark)

    Vohnsen, Brian; Bozhevolnyi, Sergey I.

    1999-01-01

    Radiation and collection characteristics of four different near-field optical-fiber probes, namely, three uncoated probes and an aluminium-coated small-aperture probe, are investigated and compared. Their radiation properties are characterized by observation of light-induced topography changes...... in a photo-sensitive film illuminated with the probes, and it is confirmed that the radiated optical field is unambigiously confined only for the coated probe. Near-field optical imaging of a standing evanescent-wave pattern is used to compare the detection characteristics of the probes, and it is concluded...... that, for the imaging of optical-field intensity distributions containing predominantly evanescent-wave components, a sharp uncoated tip is the probe of choice. Complementary results obtained with optical phase-conjugation experiments with he uncoated probes are discussed in relation to the probe...

  9. Evaluation of the Gen-Probe DNA probe for the detection of legionellae in culture

    International Nuclear Information System (INIS)

    Edelstein, P.H.

    1986-01-01

    A commercial DNA probe kit designed to detect rRNA from legionellae was evaluated for its ability to correctly discriminate between legionellae and non-legionellae taken from culture plates. The probe kit, made by the Gen-Probe Corp. (San Diego, Calif.), was radiolabeled with 125 I, and probe bacterial RNA hybridization, detected in a simple one-tube system hybridization assay, was quantitated with a gamma counter. A total of 156 Legionella sp. strains were tested, of which 125 were Legionella pneumophila and the remainder were strains from 21 other Legionella spp. A total of 106 gram-negative non-legionellae, isolated from human respiratory tract (81%) and other body site (19%) specimens, were also tested; 14 genera and 28 species were represented. The probe easily distinguished all of the legionellae from the non-legionellae. The average legionellae/non-legionellae hybridization ratio was 42:1, and the lowest ratio was 2:1; a minor modification in the procedure increased the lowest ratio to 5:1. In addition to correctly identifying all Legionella species, the probe was able to separate some of the various species of Legionella. L. pneumophila strains hybridized more completely to the probe than did the other Legionella spp.; L. wadsworthii and L. oakridgensis hybridized only about 25% of the probe relative to L. pneumophila. Some strains of phenotypically identified L. pneumophila had much lower hybridization to the probe than other members of the species and may represent a new Legionella species. The simplicity of the technique and specificity of the probe make it a good candidate for confirming the identity of legionellae in culture

  10. Smart near-infrared fluorescence probes with donor-acceptor structure for in vivo detection of β-amyloid deposits.

    Science.gov (United States)

    Cui, Mengchao; Ono, Masahiro; Watanabe, Hiroyuki; Kimura, Hiroyuki; Liu, Boli; Saji, Hideo

    2014-03-05

    The deposition of β-amyloid (Aβ) plaques in the parenchymal and cortical brain is accepted as the main pathological hallmark of Alzheimer's disease (AD); however, early detection of AD still presents a challenge. With the assistance of molecular imaging techniques, imaging agents specifically targeting Aβ plaques in the brain may lead to the early diagnosis of AD. Herein, we report the design, synthesis, and evaluation of a series of smart near-infrared fluorescence (NIRF) imaging probes with donor-acceptor architecture bridged by a conjugated π-electron chain for Aβ plaques. The chemical structure of these NIRF probes is completely different from Congo Red and Thioflavin-T. Probes with a longer conjugated π system (carbon-carbon double bond) displayed maximum emission in PBS (>650 nm), which falls in the best range for NIRF probes. These probes were proved to have affinity to Aβ plaques in fluorescent staining of brain sections from an AD patient and double transgenic mice, as well as in an in vitro binding assay using Aβ(1-42) aggregates. One probe with high affinity (K(i) = 37 nM, K(d) = 27 nM) was selected for in vivo imaging. It can penetrate the blood-brain barrier of nude mice efficiently and is quickly washed out of the normal brain. Moreover, after intravenous injection of this probe, 22-month-old APPswe/PSEN1 mice exhibited a higher relative signal than control mice over the same period of time, and ex vivo fluorescent observations confirmed the existence of Aβ plaques. In summary, this probe meets most of the requirements for a NIRF contrast agent for the detection of Aβ plaques both in vitro and in vivo.

  11. Depth probing of the hydride formation process in thin Pd films by combined electrochemistry and fiber optics-based in situ UV/vis spectroscopy.

    Science.gov (United States)

    Wickman, Björn; Fredriksson, Mattias; Feng, Ligang; Lindahl, Niklas; Hagberg, Johan; Langhammer, Christoph

    2015-07-15

    We demonstrate a flexible combined electrochemistry and fiber optics-based in situ UV/vis spectroscopy setup to gain insight into the depth evolution of electrochemical hydride and oxide formation in Pd films with thicknesses of 20 and 100 nm. The thicknesses of our model systems are chosen such that the films are thinner or significantly thicker than the optical skin depth of Pd to create two distinctly different situations. Low power white light is irradiated on the sample and analyzed in three different configurations; transmittance through, and, reflectance from the front and the back side of the film. The obtained optical sensitivities correspond to fractions of a monolayer of adsorbed or absorbed hydrogen (H) and oxygen (O) on Pd. Moreover, a combined simultaneous readout obtained from the different optical measurement configurations provides mechanistic insights into the depth-evolution of the studied hydrogenation and oxidation processes.

  12. Copper nanoclusters as probes for turn-on fluorescence sensing of L-lysine.

    Science.gov (United States)

    Zhang, Mingming; Qiao, Juan; Zhang, Shufeng; Qi, Li

    2018-05-15

    Herein, a unique protocol based on copper nanoclusters (CuNCs) probe for turn-on fluorescence sensing of L-lysine was developed. The fluorescent CuNCs with ovalbumin as the stabilizer was prepared by a simple, one-step and green method. When 370 nm was used as the excitation wavelength, the resultant CuNCs exhibited a pale blue fluorescence with the maximum emission at 440 nm. Interestingly, existence of L-lysine evoked the obvious fluorescence intensity increase of CuNCs. The detection limit of the proposed method for L-lysine was 5.5 μM, with a good linear range from 10.0 μM to 1.0 mM (r 2 = 0.999). Moreover, the possible mechanism for enhanced fluorescence intensity of CuNCs by addition of L-lysine was explored and discussed briefly. Further, the as-prepared fluorescent CuNCs was successfully applied in detection of L-lysine in urine. Our results demonstrated that L-lysine could be monitored by the probe, providing new path for construction of CuNCs as fluorescent probes and showing great potential in quantification of L-lysine in real samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Where do pulse oximeter probes break?

    Science.gov (United States)

    Crede, S; Van der Merwe, G; Hutchinson, J; Woods, D; Karlen, W; Lawn, J

    2014-06-01

    Pulse oximetry, a non-invasive method for accurate assessment of blood oxygen saturation (SPO2), is an important monitoring tool in health care facilities. However, it is often not available in many low-resource settings, due to expense, overly sophisticated design, a lack of organised procurement systems and inadequate medical device management and maintenance structures. Furthermore medical devices are often fragile and not designed to withstand the conditions of low-resource settings. In order to design a probe, better suited to the needs of health care facilities in low-resource settings this study aimed to document the site and nature of pulse oximeter probe breakages in a range of different probe designs in a low to middle income country. A retrospective review of job cards relating to the assessment and repair of damaged or faulty pulse oximeter probes was conducted at a medical device repair company based in Cape Town, South Africa, specializing in pulse oximeter probe repairs. 1,840 job cards relating to the assessment and repair of pulse oximeter probes were reviewed. 60.2 % of probes sent for assessment were finger-clip probes. For all probes, excluding the neonatal wrap probes, the most common point of failure was the probe wiring (>50 %). The neonatal wrap most commonly failed at the strap (51.5 %). The total cost for quoting on the broken pulse oximeter probes and for the subsequent repair of devices, excluding replacement components, amounted to an estimated ZAR 738,810 (USD $98,508). Improving the probe wiring would increase the life span of pulse oximeter probes. Increasing the life span of probes will make pulse oximetry more affordable and accessible. This is of high priority in low-resource settings where frequent repair or replacement of probes is unaffordable or impossible.

  14. Tree tomato water requirements determined by neutron probe

    International Nuclear Information System (INIS)

    1994-01-01

    The dynamics of water was studied at ''La Tola'', experimental teaching center of the Central University of Ecuador, in a sandy-loan, typic durustoll soil in which trees tomato were growing. All the components of the crop water balance were determined. Real evapotranspiration (ETR) was estimated through the mass balance method, using every 5-10 days a neutron probe to access the volumetric humidity of the soil. The real evapotranspiration was in direct relation with the growth of the crop, reaching its maximum value of 3,8 mm day-1, at vegetative stage. The soil layer supplying most of the water for the consumptive use of the crop was between 0-40 cm being the root activity also greater in that layer

  15. Development of high pressure conductivity probe (HPCP) for secondary shut down system (SDS-2) of 500 MWe PHWR

    International Nuclear Information System (INIS)

    Sapra, M.K.; Kundu, S.; Mohan, L.R.

    2003-09-01

    The poison solution and the moderator in Secondary Shutdown System (SDS-2) of 500 MWe PHWR, are separated by their own liquid in liquid interface. This interface moves towards the calandria because of molecular diffusion, temperature difference and physical disturbances in the moderator level. It is proposed to install two numbers of high pressure conductivity probes (HPCP) to monitor the interface movement as well as to provide the safe annunciation value for interface location. On actuation of the SDS-2 signal, high-pressure helium will inject the poison into the moderator to shutdown the reactor. During poison injection, these probes will experience high pressure of nearly 85 kg/sq.cm. Global market survey indicated that conductivity probes having built in temperature sensor are available for a maximum pressure rating of 35 kg/sq.cm. Hence in order to meet the process requirement of SDS-2, the development of HPCP suitable for a pressure of 85 kg/sq.cm. was taken up. Two numbers of such probes were successfully designed, fabricated and evaluated for their performance. The developed conductivity probes fully meet the laid design and performance criteria. The aforesaid development work was a successful endeavour towards indigenisation of high-pressure conductivity probe for future applications. This report deals with the design aspects, fabrication technique, material and performance evajuation criteria and test results of HPCP. (author)

  16. Method of shaping of direction-characterization of sensitivity of ionizing radiation detection probe

    International Nuclear Information System (INIS)

    Czarnecki, J.; Jaszczuk, J.; Kruczyk, M.; Slapa, M.; Wroblewski, T.

    1986-01-01

    A method of shaping of direction-characterization of sensitivity of the ionizing radiation detection probe, especially equipped with small gamma detectors is described. Two detectors are placed coaxially in the bases of the cylindrical shield. One of them is uncovered in the highest degree and the second is not covered to a maximum. The signals from them are processed on the standarized sequences of electrical impulses (taking into account the heights and the widths of the amplitude). 2 figs., 1 tab. (A.S.)

  17. Design and technical evaluation of fibre-coupled Raman probes for the image-guided discrimination of cancerous skin

    International Nuclear Information System (INIS)

    Schleusener, J; Reble, C; Helfmann, J; Gersonde, I; Cappius, H-J; Glanert, M; Fluhr, J W; Meinke, M C

    2014-01-01

    Two different designs for fibre-coupled Raman probes are presented that are optimized for discriminating cancerous and normal skin by achieving high epithelial sensitivity to detect a major component of the Raman signal from the depth range of the epithelium. This is achieved by optimizing Raman spot diameters to the range of ≈200 µm, which distinguishes this approach from the common applications of either Raman microspectroscopy (1–5 µm) or measurements on larger sampling volume using spot sizes of a few mm. Video imaging with a depicted area in the order of a few cm, to allow comparing Raman measurements to the location of the histo-pathologic findings, is integrated in both designs. This is important due to the inhomogeneity of cancerous lesions. Video image acquisition is achieved using white light LED illumination, which avoids ambient light artefacts. The design requirements focus either on a compact light-weight configuration, for pen-like handling, or on a video-visible measurement spot to enable increased positioning accuracy. Both probes are evaluated with regard to spot size, Rayleigh suppression, background fluorescence, depth sensitivity, clinical handling and ambient light suppression. Ex vivo measurements on porcine ear skin correlates well with findings of other groups. (paper)

  18. Monte Carlo modeling of time-resolved fluorescence for depth-selective interrogation of layered tissue.

    Science.gov (United States)

    Pfefer, T Joshua; Wang, Quanzeng; Drezek, Rebekah A

    2011-11-01

    Computational approaches for simulation of light-tissue interactions have provided extensive insight into biophotonic procedures for diagnosis and therapy. However, few studies have addressed simulation of time-resolved fluorescence (TRF) in tissue and none have combined Monte Carlo simulations with standard TRF processing algorithms to elucidate approaches for cancer detection in layered biological tissue. In this study, we investigate how illumination-collection parameters (e.g., collection angle and source-detector separation) influence the ability to measure fluorophore lifetime and tissue layer thickness. Decay curves are simulated with a Monte Carlo TRF light propagation model. Multi-exponential iterative deconvolution is used to determine lifetimes and fractional signal contributions. The ability to detect changes in mucosal thickness is optimized by probes that selectively interrogate regions superficial to the mucosal-submucosal boundary. Optimal accuracy in simultaneous determination of lifetimes in both layers is achieved when each layer contributes 40-60% of the signal. These results indicate that depth-selective approaches to TRF have the potential to enhance disease detection in layered biological tissue and that modeling can play an important role in probe design optimization. Published by Elsevier Ireland Ltd.

  19. Flow of Energy through the Inner Magnetosphere during the March 17, 2015 solar storm as observed by the Van Allen Probes Radiation Belt Storm Probes Ion Composition Experiment (RBSPICE)

    Science.gov (United States)

    Manweiler, J. W.; Madanian, H.; Gerrard, A. J.; Patterson, J. D.; Mitchell, D. G.; Lanzerotti, L. J.

    2017-12-01

    On March 17, 2015, a large solar storm impacted the Earth's magnetosphere with a maximum negative Dst of -232 nT. We report on the temporal and spatial evolution of the proton energetic particle distributions in phase space during this storm, as measured by the Radiation Belt Storm Probes Ion Composition Experiment (RBSPICE) instrument on board each of the Van Allen Probes. We characterize the distribution prior to onset of the storm to provide a definition of quiet time conditions. We then show how the distribution evolves during the storm noting key changes of the distribution as a function of L and MLT and showing how the pitch angle distributions change throughout the storm. These observations displayed a number of interesting features of the storm including high beta plasma conditions and multiple injections of protons into the inner magnetosphere. We present the radial changes of the distribution at storm onset and following the evolution of the distribution during storm recovery. We compare observations of the East/West asymmetry in the proton distribution before versus after onset using both Van Allen Probes A and B spacecraft observations. Finally, we note interesting changes in the distribution showing an anomalous dropout in mid-energies of the distribution and observe an outward radial propagation of this dropout during recovery.

  20. Effect of the depth base along the vertical on the electrical parameters of a vertical parallel silicon solar cell in open and short circuit

    Science.gov (United States)

    Sahin, Gokhan; Kerimli, Genber

    2018-03-01

    This article presented a modeling study of effect of the depth base initiating on vertical parallel silicon solar cell's photovoltaic conversion efficiency. After the resolution of the continuity equation of excess minority carriers, we calculated the electrical parameters such as the photocurrent density, the photovoltage, series resistance and shunt resistances, diffusion capacitance, electric power, fill factor and the photovoltaic conversion efficiency. We determined the maximum electric power, the operating point of the solar cell and photovoltaic conversion efficiency according to the depth z in the base. We showed that the photocurrent density decreases with the depth z. The photovoltage decreased when the depth base increases. Series and shunt resistances were deduced from electrical model and were influenced and the applied the depth base. The capacity decreased with the depth z of the base. We had studied the influence of the variation of the depth z on the electrical parameters in the base.

  1. Visual Discomfort and Depth-of-Field

    Directory of Open Access Journals (Sweden)

    Louise O'Hare

    2013-05-01

    Full Text Available Visual discomfort has been reported for certain visual stimuli and under particular viewing conditions, such as stereoscopic viewing. In stereoscopic viewing, visual discomfort can be caused by a conflict between accommodation and convergence cues that may specify different distances in depth. Earlier research has shown that depth-of-field, which is the distance range in depth in the scene that is perceived to be sharp, influences both the perception of egocentric distance to the focal plane, and the distance range in depth between objects in the scene. Because depth-of-field may also be in conflict with convergence and the accommodative state of the eyes, we raised the question of whether depth-of-field affects discomfort when viewing stereoscopic photographs. The first experiment assessed whether discomfort increases when depth-of-field is in conflict with coherent accommodation–convergence cues to distance in depth. The second experiment assessed whether depth-of-field influences discomfort from a pre-existing accommodation–convergence conflict. Results showed no effect of depth-of-field on visual discomfort. These results suggest therefore that depth-of-field can be used as a cue to depth without inducing discomfort in the viewer, even when cue conflicts are large.

  2. Unstability of the Fulde-Ferrell state in d-wave superconductors by calculating the magnetic penetration depth

    International Nuclear Information System (INIS)

    Rabani, H.; Shahzamanian, M.A.; Yavary, H.

    2007-01-01

    Full text: Fulde, Ferrell, Larkin and Ovchnnikov (FFLO), first proposed the possibility that a superconducting state with a periodic spatial variation of the gap parameter would become stable when a large Zeeman splinting is present [1,2]. The order parameter varies periodically in space when the Pauli paramagnetism or the Zeeman term dominates the orbital effect. The Zeeman splitting could be due to either a strong magnetic field or an internal exchange field. Under these fields there is a splitting of the Fermi surfaces of spin up and spin down electrons, and the condensed pair has a non-zero total momentum, 2q, which causes the phase of the superconducting order parameter to vary. This state is known as the FF state. We determine the penetration depth of the Fulde-Ferrell State (FF) for quasi-two dimensional (2D) d-wave superconductor by calculating the electromagnetic nonlocal kernel response function. The behavior of the penetration depth at low temperatures is an important probe to determine the stability of the FF state. We start from a mean field Hamiltonian for the FF state and we calculate the electromagnetic nonlocal response tensor relating the current density to an applied vector potential to determine the magnetic penetration depth. We show that a linear T dependence of the magnetic penetration depth in the FF state superconductor violates indeed the third law of thermodynamics and the FF state is unstable due to Nernst theorem. (authors)

  3. Determination of electron depth-dose curves for water, ICRU tissue, and PMMA and their application to radiation protection dosimetry

    International Nuclear Information System (INIS)

    Grosswendt, B.

    1994-01-01

    For monoenergetic electrons in the energy range between 60 keV and 10 MeV, normally incident on water, 4-element ICRU tissue and PMMA phantoms, depth-dose curves have been calculated using the Monte Carlo method. The phantoms' shape was that of a rectangular solid with a square front face of 30 cm x 30 cm and a thickness of 15 cm; it corresponds to that recommended by the ICRU for use in the procedure of calibrating radiation protection dosemeters. The depth-dose curves have been used to determine practical ranges, half-value depths, electron fluence to maximum absorbed dose conversion factors, and conversion factors between electron fluence and absorbed dose at depths d corresponding to 0.007 g.cm -2 , 0.3 g.cm -2 , and 1.0 g.cm -2 . The latter data can be used as fluence to dose equivalent conversion factors for extended parallel electron beams. (Author)

  4. A new intracavitary probe for detecting the site of origin of ectopic ventricular beats during one cardiac cycle.

    Science.gov (United States)

    Taccardi, B; Arisi, G; Macchi, E; Baruffi, S; Spaggiari, S

    1987-01-01

    An olive-shaped probe (25 X 12 mm) with 41 evenly distributed recording electrodes on its surface was introduced into the left ventricles of seven open-chest dogs via the left atrium. In two other dogs a cylindrical probe (40 X 3 mm) was used. Electrical stimuli were delivered at 66 endocardial, midwall, or epicardial sites in the left and right ventricular walls and the septum. Mechanical stimuli were also applied at various epicardial sites. On-line mapping of equipotential contour lines on the surface of the probe invariably revealed a clear-cut potential minimum on the electrode that faced the pacing site. Time of appearance of potential minimum was 3 to 5 msec after endocardial stimuli, 10 to 25 msec for midwall and epicardial pacing, and 30 msec or more for right ventricular stimulation. Simultaneous stimulation at two sites 1.2 cm apart gave rise to two separate minima on the maps. "Pseudoisochrones" derived from electrograms recorded by the new probe were slightly less accurate in indicating the site of origin of extrasystoles. We conclude that equipotential and "isochrone" contour maps recorded from an array of semidirect electrodes, regularly distributed on the surface of an intraventricular probe, provide information on the site of origin (location and intramural depth) of ectopic paced beats in a normal dog heart.

  5. NeuroMEMS: Neural Probe Microtechnologies

    Directory of Open Access Journals (Sweden)

    Sam Musallam

    2008-10-01

    Full Text Available Neural probe technologies have already had a significant positive effect on our understanding of the brain by revealing the functioning of networks of biological neurons. Probes are implanted in different areas of the brain to record and/or stimulate specific sites in the brain. Neural probes are currently used in many clinical settings for diagnosis of brain diseases such as seizers, epilepsy, migraine, Alzheimer’s, and dementia. We find these devices assisting paralyzed patients by allowing them to operate computers or robots using their neural activity. In recent years, probe technologies were assisted by rapid advancements in microfabrication and microelectronic technologies and thus are enabling highly functional and robust neural probes which are opening new and exciting avenues in neural sciences and brain machine interfaces. With a wide variety of probes that have been designed, fabricated, and tested to date, this review aims to provide an overview of the advances and recent progress in the microfabrication techniques of neural probes. In addition, we aim to highlight the challenges faced in developing and implementing ultralong multi-site recording probes that are needed to monitor neural activity from deeper regions in the brain. Finally, we review techniques that can improve the biocompatibility of the neural probes to minimize the immune response and encourage neural growth around the electrodes for long term implantation studies.

  6. Depth-acclimation of photosynthesis, morphology and demography of Posidonia oceanica and Cymodocea nodosa in the Spanish Mediterranean Sea

    DEFF Research Database (Denmark)

    Olesen, B.; Enríquez, Susana; Duarte, Carlos M.

    2002-01-01

    and roots at greater depths, thereby promoting the balance between photosynthesis and respiration in the shoots. C. nodosa, being a potentially fast-growing species compared to P. oceanica, had higher maximum photosynthetic and respiration rates as well as light compensation points for photosynthesis....... Photosynthetic efficiency at low light, however, was almost the same for the 2 species as suggested by the relatively small differences in mass-specific light absorption. Only C. nodosa acclimated physiologically to depth as light-use efficiency increased, and light compensation point declined significantly from...... shallow to deep water. P. oceanica, however, possessed low respiration rates and slightly lower light compensation points values than C. nodosa throughout the depth range. Shoot mortality and recruitment rates were unaffected by rooting depth. C. nodosa stand experienced fast shoot turnover compared to P...

  7. Establishment of a novel immunoassay system for rapid detection of 2,4-dichlorophenoxyacetic acid residues based on magnetic-fluorescent probes

    Directory of Open Access Journals (Sweden)

    WANG Yuanfeng

    2014-12-01

    Full Text Available A novel immunoassay system based on magnetic-fluorescent probes was established to detect 2.4-dichlorophenoxyacetic acid (2,4-D residue in liquid system in food and agricultural products.The composites of anti-2,4-D antibody bound to Fe3O4@SiO2-NH2 was employed as the solid phase as well as magnetic probe.The composites composed of 2,4-D-OVA labeled with CdTe@SiO2-NH2 as the fluorescent probe was used to produce fluorescent signal.2,4-D and its fluorescent probe competed binding the antibody on the surface of the magnetic probe.The optimization of 2,4-D-OVA dosage,coupling PH and reaction time in preparing the fluorescent probe were investigated.It showed that in the synthesis of fluorescent probe 8.2 was the optimal pH,70 min was the optimal coupling time,500 μL amount of 2,4-D-OVA.The standard curve was obtained with the concentration of 2,4-D and the maximum fluorescence intensity.The detection limit of the assay was gotten and it was 3.55×10-8.One reaction step and one washing step were needed.The assay significantly shortened the testing time and amplified the detection signal compared with classic ELISA.

  8. Neutron and gamma probes: Their use in agronomy. Second edition

    International Nuclear Information System (INIS)

    2003-01-01

    Water is an essential requirement for life on the planet. It is often the single most limiting factor in crop and livestock production. Water is a scarce resource in many urban and rural environments worldwide. According to the FAO, the global demand for fresh water is doubling every 21 years. The quality of the finite water supplies is also under threat from industrial, agricultural and domestic sources of pollution. The majority of crops are grown under rain-fed conditions and adequate water supply is the main factor limiting crop production in semi-arid and sub-humid regions. On the other hand, currently 20% of the world's arable land is under irrigation providing 35 to 40% of all agricultural production. Irrigation mismanagement poses a serious threat to the environment through groundwater pollution and salinization. It is therefore, essential that water resources be used efficiently by regular monitoring of soil-water status in the unsaturated zone. The neutron depth probe, a nuclear-based technique, is utilized worldwide for this purpose. The neutron moisture gauge, since its introduction some 40 years ago, can now be considered a routine method in soil water studies. Many developments have since been introduced, in particular electronic components, which have significantly improved performance and expanded applications. Although the neutron scattering method is routinely utilised in many developed countries, its use is still limited in developing countries due to several factors. Neutron depth probes contain radioactive sources, which will present health and environmental hazards if a probe is improperly used, stored or disposed of. National and international legislation and regulations must be complied with. The strategic objective of the sub-program Soil and Water Management and Crop Nutrition of the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture is to develop and promote the adoption of nuclear-based technologies for optimising soil

  9. Magnetotelluric Detection Thresholds as a Function of Leakage Plume Depth, TDS and Volume

    Energy Technology Data Exchange (ETDEWEB)

    Yang, X. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Buscheck, T. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mansoor, K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Carroll, S. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-04-21

    We conducted a synthetic magnetotelluric (MT) data analysis to establish a set of specific thresholds of plume depth, TDS concentration and volume for detection of brine and CO2 leakage from legacy wells into shallow aquifers in support of Strategic Monitoring Subtask 4.1 of the US DOE National Risk Assessment Partnership (NRAP Phase II), which is to develop geophysical forward modeling tools. 900 synthetic MT data sets span 9 plume depths, 10 TDS concentrations and 10 plume volumes. The monitoring protocol consisted of 10 MT stations in a 2×5 grid laid out along the flow direction. We model the MT response in the audio frequency range of 1 Hz to 10 kHz with a 50 Ωm baseline resistivity and the maximum depth up to 2000 m. Scatter plots show the MT detection thresholds for a trio of plume depth, TDS concentration and volume. Plumes with a large volume and high TDS located at a shallow depth produce a strong MT signal. We demonstrate that the MT method with surface based sensors can detect a brine and CO2 plume so long as the plume depth, TDS concentration and volume are above the thresholds. However, it is unlikely to detect a plume at a depth larger than 1000 m with the change of TDS concentration smaller than 10%. Simulated aquifer impact data based on the Kimberlina site provides a more realistic view of the leakage plume distribution than rectangular synthetic plumes in this sensitivity study, and it will be used to estimate MT responses over simulated brine and CO2 plumes and to evaluate the leakage detectability. Integration of the simulated aquifer impact data and the MT method into the NRAP DREAM tool may provide an optimized MT survey configuration for MT data collection. This study presents a viable approach for sensitivity study of geophysical monitoring methods for leakage detection. The results come in handy for rapid assessment of leakage detectability.

  10. Maximum entropy methods for extracting the learned features of deep neural networks.

    Science.gov (United States)

    Finnegan, Alex; Song, Jun S

    2017-10-01

    New architectures of multilayer artificial neural networks and new methods for training them are rapidly revolutionizing the application of machine learning in diverse fields, including business, social science, physical sciences, and biology. Interpreting deep neural networks, however, currently remains elusive, and a critical challenge lies in understanding which meaningful features a network is actually learning. We present a general method for interpreting deep neural networks and extracting network-learned features from input data. We describe our algorithm in the context of biological sequence analysis. Our approach, based on ideas from statistical physics, samples from the maximum entropy distribution over possible sequences, anchored at an input sequence and subject to constraints implied by the empirical function learned by a network. Using our framework, we demonstrate that local transcription factor binding motifs can be identified from a network trained on ChIP-seq data and that nucleosome positioning signals are indeed learned by a network trained on chemical cleavage nucleosome maps. Imposing a further constraint on the maximum entropy distribution also allows us to probe whether a network is learning global sequence features, such as the high GC content in nucleosome-rich regions. This work thus provides valuable mathematical tools for interpreting and extracting learned features from feed-forward neural networks.

  11. Defects introduced by Ar plasma exposure in GaAs probed by monoenergetic positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Kawano, Takao; Wada, Kazumi; Nakanishi, Hideo

    1994-10-01

    Ar-plasma-induced defects in n-type GaAs were probed by a monoenergetic positron beam. The depth distribution of the defects was obtained from measurements of Doppler broadening profiles of the annihilation radiation as a function of incident positron energy. The damaged layer induced by the exposure was found to extend far beyond the stopping range of Ar ions, and the dominant defects were identified as interstitial-type defects. After 100degC annealing, such defects were annealed. Instead, vacancy-type defects were found to be the dominant defects in the subsurface region. (author).

  12. Preventing probe induced topography correlated artifacts in Kelvin Probe Force Microscopy

    NARCIS (Netherlands)

    Polak, L.; Wijngaarden, Rinke J.

    2016-01-01

    Kelvin Probe Force Microscopy (KPFM) on samples with rough surface topography can be hindered by topography correlated artifacts. We show that, with the proper experimental configuration and using homogeneously metal coated probes, we are able to obtain amplitude modulation (AM) KPFM results on a

  13. Redox Probing Study of the Potential Dependence of Charge Transport Through Li2O2

    DEFF Research Database (Denmark)

    Knudsen, Kristian Bastholm; Luntz, Alan C.; Jensen, Søren Højgaard

    2015-01-01

    -of-the-art Liion technologies and the demand placed on batteries by technologies such as electrical vehicles. Here we present a redox probing study of the charge transfer across the main deposition product lithium peroxide, Li2O2, in the Li−O2 battery using outer-sphere redox shuttles. The change in heterogeneous......In the field of energy storage devices the pursuit for cheap, high energy density, reliable secondary batteries is at the top of the agenda. The Li−O2 battery is one of the possible technologies that, in theory, should be able to close the gap, which exists between the present state...... electron transfer exchange rate as a function of the potential and the Li2O2 layer thickness (∼depth-of-discharge) was determined using electrochemical impedance spectroscopy. The attenuation of the electron transfer exchange rate with film thickness is dependent on the probing potential, providing...

  14. Accuracy of micro four-point probe measurements on inhomogeneous samples: A probe spacing dependence study

    DEFF Research Database (Denmark)

    Wang, Fei; Petersen, Dirch Hjorth; Østerberg, Frederik Westergaard

    2009-01-01

    In this paper, we discuss a probe spacing dependence study in order to estimate the accuracy of micro four-point probe measurements on inhomogeneous samples. Based on sensitivity calculations, both sheet resistance and Hall effect measurements are studied for samples (e.g. laser annealed samples...... the probe spacing is smaller than 1/40 of the variation wavelength, micro four-point probes can provide an accurate record of local properties with less than 1% measurement error. All the calculations agree well with previous experimental results.......) with periodic variations of sheet resistance, sheet carrier density, and carrier mobility. With a variation wavelength of ¿, probe spacings from 0.0012 to 1002 have been applied to characterize the local variations. The calculations show that the measurement error is highly dependent on the probe spacing. When...

  15. Wearable probes for service design

    DEFF Research Database (Denmark)

    Mullane, Aaron; Laaksolahti, Jarmo Matti; Svanæs, Dag

    2014-01-01

    Probes are used as a design method in user-centred design to allow end-users to inform design by collecting data from their lives. Probes are potentially useful in service innovation, but current probing methods require users to interrupt their activity and are consequently not ideal for use...... by service employees in reflecting on the delivery of a service. In this paper, we present the ‘wearable probe’, a probe concept that captures sensor data without distracting service employees. Data captured by the probe can be used by the service employees to reflect and co-reflect on the service journey......, helping to identify opportunities for service evolution and innovation....

  16. Subring Depth, Frobenius Extensions, and Towers

    Directory of Open Access Journals (Sweden)

    Lars Kadison

    2012-01-01

    Full Text Available The minimum depth d(B,A of a subring B⊆A introduced in the work of Boltje, Danz and Külshammer (2011 is studied and compared with the tower depth of a Frobenius extension. We show that d(B,A < ∞ if A is a finite-dimensional algebra and Be has finite representation type. Some conditions in terms of depth and QF property are given that ensure that the modular function of a Hopf algebra restricts to the modular function of a Hopf subalgebra. If A⊇B is a QF extension, minimum left and right even subring depths are shown to coincide. If A⊇B is a Frobenius extension with surjective Frobenius, homomorphism, its subring depth is shown to coincide with its tower depth. Formulas for the ring, module, Frobenius and Temperley-Lieb structures are noted for the tower over a Frobenius extension in its realization as tensor powers. A depth 3 QF extension is embedded in a depth 2 QF extension; in turn certain depth n extensions embed in depth 3 extensions if they are Frobenius extensions or other special ring extensions with ring structures on their relative Hochschild bar resolution groups.

  17. Aspheric surface measurement using capacitive probes

    Science.gov (United States)

    Tao, Xin; Yuan, Daocheng; Li, Shaobo

    2017-02-01

    With the application of aspheres in optical fields, high precision and high efficiency aspheric surface metrology becomes a hot research topic. We describe a novel method of non-contact measurement of aspheric surface with capacitive probe. Taking an eccentric spherical surface as the object of study, the averaging effect of capacitive probe measurement and the influence of tilting the capacitive probe on the measurement results are investigated. By comparing measurement results from simultaneous measurement of the capacitive probe and contact probe of roundness instrument, this paper indicates the feasibility of using capacitive probes to test aspheric surface and proposes the compensation method of measurement error caused by averaging effect and the tilting of the capacitive probe.

  18. Cosmic shear measurement with maximum likelihood and maximum a posteriori inference

    Science.gov (United States)

    Hall, Alex; Taylor, Andy

    2017-06-01

    We investigate the problem of noise bias in maximum likelihood and maximum a posteriori estimators for cosmic shear. We derive the leading and next-to-leading order biases and compute them in the context of galaxy ellipticity measurements, extending previous work on maximum likelihood inference for weak lensing. We show that a large part of the bias on these point estimators can be removed using information already contained in the likelihood when a galaxy model is specified, without the need for external calibration. We test these bias-corrected estimators on simulated galaxy images similar to those expected from planned space-based weak lensing surveys, with promising results. We find that the introduction of an intrinsic shape prior can help with mitigation of noise bias, such that the maximum a posteriori estimate can be made less biased than the maximum likelihood estimate. Second-order terms offer a check on the convergence of the estimators, but are largely subdominant. We show how biases propagate to shear estimates, demonstrating in our simple set-up that shear biases can be reduced by orders of magnitude and potentially to within the requirements of planned space-based surveys at mild signal-to-noise ratio. We find that second-order terms can exhibit significant cancellations at low signal-to-noise ratio when Gaussian noise is assumed, which has implications for inferring the performance of shear-measurement algorithms from simplified simulations. We discuss the viability of our point estimators as tools for lensing inference, arguing that they allow for the robust measurement of ellipticity and shear.

  19. Emission Depth Distribution Function of Al 2s Photoelectrons in Al2O3

    Science.gov (United States)

    Hucek, S.; Zemek, J.; Jablonski, A.; Tilinin, I. S.

    The escape probability of Al 2s photoelectrons leaving an aluminum oxide sample (Al2O3) has been studied as a function of depth of origin. It has been found that the escape probability (the so-called emission depth distribution function - DDF) depends strongly on the photoelectron emission direction with respect to that of the incident X-ray beam. In particular, in the emission direction close to that of photon propagation, the DDF differs substantially from the simple Beer-Lambert law and exhibits a nonmonotonic behavior with a maximum in the near-surface region at a depth of about 10 Å. Experimental results are in good agreement with theoretical predictions based on Monte Carlo simulations of the electron transport and with analytical solution of the linearized Boltzmann kinetic equation with appropriate boundary conditions. Both theoretical approaches take into account multiple elastic scattering of photoelectrons on their way out of the sample. It is shown that the commonly used straight line approximation (SLA), which neglects elastic scattering effects, fails to describe adequately experimental data at emission directions close to minima of the differential photoelectric cross section.

  20. Diffusion studies on permeable nitroxyl spin probes through bilayer lipid membranes: A low frequency ESR study

    International Nuclear Information System (INIS)

    Meenakumari, V.; Benial, A. Milton Franklin; Utsumi, Hideo; Ichikawa, Kazuhiro; Yamada, Ken-ichi; Hyodo, Fuminori; Jawahar, A.

    2015-01-01

    Electron spin resonance (ESR) studies were carried out for permeable 2mM 14 N-labeled deutrated 3 Methoxy carbonyl-2,2,5,5-tetramethyl-pyrrolidine-1-oxyl (MC-PROXYL) in pure water and 1mM, 2mM, 3mM, 4mM concentration of 14N-labeled deutrated MC-PROXYL in 400mM concentration of liposomal solution by using a 300 MHz ESR spectrometer. The ESR parameters such as linewidth, hyperfine coupling constant, g-factor, partition parameter and permeability were reported for these samples. The line broadening was observed for the nitroxyl spin probe in the liposomal solution. The line broadening indicates that the high viscous nature of the liposomal solution. The partition parameter and permeability values indicate the maximum diffusion of nitroxyl spin probes in the bilayer lipid membranes at 2 mM concentration of nitroxyl radical. This study illustrates that ESR can be used to differentiate between the intra and extra- membrane water by loading the liposome vesicles with a lipid-permeable nitroxyl spin probe. From the ESR results, the spin probe concentration was optimized as 2mM in liposomal solution for ESR phantom studies/imaging, invivo and invitro experiments

  1. Diffraction enhanced kinetic depth X-ray imaging

    Science.gov (United States)

    Dicken, A.

    An increasing number of fields would benefit from a single analytical probe that can characterise bulk objects that vary in morphology and/or material composition. These fields include security screening, medicine and material science. In this study the X-ray region is shown to be an effective probe for the characterisation of materials. The most prominent analytical techniques that utilise X-radiation are reviewed. The study then focuses on methods of amalgamating the three dimensional power of kinetic depth X-ray (KDFX) imaging with the materials discrimination of angular dispersive X-ray diffraction (ADXRD), thus providing KDEX with a much needed material specific counterpart. A knowledge of the sample position is essential for the correct interpretation of diffraction signatures. Two different sensor geometries (i.e. circumferential and linear) that are able to collect end interpret multiple unknown material diffraction patterns and attribute them to their respective loci within an inspection volume are investigated. The circumferential and linear detector geometries are hypothesised, simulated and then tested in an experimental setting with the later demonstrating a greater ability at discerning between mixed diffraction patterns produced by differing materials. Factors known to confound the linear diffraction method such as sample thickness and radiation energy have been explored and quantified with a possible means of mitigation being identified (i.e. via increasing the sample to detector distance). A series of diffraction patterns (following the linear diffraction approach) were obtained from a single phantom object that was simultaneously interrogated via KDEX imaging. Areas containing diffraction signatures matched from a threat library have been highlighted in the KDEX imagery via colour encoding and match index is inferred by intensity. This union is the first example of its kind and is called diffraction enhanced KDEX imagery. Finally an additional

  2. Cantilevered probe detector with piezoelectric element

    Science.gov (United States)

    Adams, Jesse D; Sulchek, Todd A; Feigin, Stuart C

    2013-04-30

    A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

  3. The time domain triple probe method

    International Nuclear Information System (INIS)

    Meier, M.A.; Hallock, G.A.; Tsui, H.Y.W.; Bengtson, R.D.

    1994-01-01

    A new Langmuir probe technique based on the triple probe method is being developed to provide simultaneous measurement of plasma temperature, potential, and density with the temporal and spatial resolution required to accurately characterize plasma turbulence. When the conventional triple probe method is used in an inhomogeneous plasma, local differences in the plasma measured at each probe introduce significant error in the estimation of turbulence parameters. The Time Domain Triple Probe method (TDTP) uses high speed switching of Langmuir probe potential, rather than spatially separated probes, to gather the triple probe information thus avoiding these errors. Analysis indicates that plasma response times and recent electronics technology meet the requirements to implement the TDTP method. Data reduction techniques of TDTP data are to include linear and higher order correlation analysis to estimate fluctuation induced particle and thermal transport, as well as energy relationships between temperature, density, and potential fluctuations

  4. Application of the resonant 52(p,γ)53Mn reaction to the measurement of chromium depth distributions

    International Nuclear Information System (INIS)

    Switkowski, Z.E.; Petty, R.J.; Clark, G.J.

    1979-01-01

    A resonance in the 52 Cr(p,γ) 53 Mn reaction has been investigated as a probe for the quantitative determination of chromium depth distributions. The relevant nuclear parameters of this resonance were measured to be: resonance energy, Esub(p)1005.2 +- 0.2 keV, total width GAMMA < 100 eV, and resonance strength, (2J+1)GAMMAsub(p)GAMMAsub(γ)/GAMMA = 0.89 +-0.11 eV. As an example of the use of the nuclear resonance technique, the chromium profile of an electroplated chrome black solar absorber surface has been studied and the results are presented

  5. Transmit-receive eddy current probes

    International Nuclear Information System (INIS)

    Obrutsky, L.S.; Sullivan, S.P.; Cecco, V.S.

    1997-01-01

    In the last two decades, due to increased inspection demands, eddy current instrumentation has advanced from single-frequency, single-output instruments to multifrequency, computer-aided systems. This has significantly increased the scope of eddy current testing, but, unfortunately, it has also increased the cost and complexity of inspections. In addition, this approach has not always improved defect detectability or signal-to-noise. Most eddy current testing applications are still performed with impedance probes, which have well known limitations. However, recent research at AECL has led to improved eddy current inspections through the design and development of transmit-receive (T/R) probes. T/R eddy current probes, with laterally displaced transmit and receive coils, present a number of advantages over impedance probes. They have improved signal-to-noise ratio in the presence of variable lift-off compared to impedance probes. They have strong directional properties, permitting probe optimization for circumferential or axial crack detection, and possess good phase discrimination to surface defects. They can significantly increase the scope of eddy current testing permitting reliable detection and sizing of cracks in heat exchanger tubing as well as in welded areas of both ferritic and non-ferromagnetic components. This presentation will describe the operating principles of T/R probes with the help of computer-derived normalized voltage diagrams. We will discuss their directional properties and analyze the advantages of using single and multiple T/R probes over impedance probes for specific inspection cases. Current applications to surface and tube testing and some typical inspection results will be described. (author)

  6. Water cooled static pressure probe

    Science.gov (United States)

    Lagen, Nicholas T. (Inventor); Eves, John W. (Inventor); Reece, Garland D. (Inventor); Geissinger, Steve L. (Inventor)

    1991-01-01

    An improved static pressure probe containing a water cooling mechanism is disclosed. This probe has a hollow interior containing a central coolant tube and multiple individual pressure measurement tubes connected to holes placed on the exterior. Coolant from the central tube symmetrically immerses the interior of the probe, allowing it to sustain high temperature (in the region of 2500 F) supersonic jet flow indefinitely, while still recording accurate pressure data. The coolant exits the probe body by way of a reservoir attached to the aft of the probe. The pressure measurement tubes are joined to a single, larger manifold in the reservoir. This manifold is attached to a pressure transducer that records the average static pressure.

  7. Nuclear reactor vessel surface inspecting technique applying electric resistance probe

    International Nuclear Information System (INIS)

    Yamaguchi, T.; Enami, K.; Yoshioka, M.

    1975-01-01

    A new technique for inspecting the inner surface of the PWR type nuclear reactor vessel by use of an electric resistance probe is introduced, centering on a data processing system. This system is composed of a mini-computer, a system typewriter, an interface unit, a D-A converter and controller, and X-Y recorder and others. Its functions are judging flaws and making flaw detection maps. In order to judge flaws by flaw detection signals, three kinds of flaw judging methods have been developed. In case there is a flaw, its position and depth are calculated and listed on the system typewriter. The flaw detection maps are expressed in four kinds of modes and they are displayed on the X-Y recorder. (auth.)

  8. Atom-probe field-ion-microscopy study of Fe-Ti alloys

    International Nuclear Information System (INIS)

    Pickering, H.W.; Kuk, Y.; Sakurai, T.

    1980-01-01

    A newly developed high-performance atom-probe (field ion microscope) was employed for the composition analysis of Fe-Ti alloys and their interactions with ambient gas, such as H 2 and O 2 . With a mass resolution (m/Δm) better than 2000 and a spatial resolution of a few A, all isotopes of Fe and Ti and their hydrides and other compounds are clearly resolved during the depth profile study. Some of our findings are: (1) Titanium segregated on the surface and grain boundaries upon heating (greater than or equal to 900 0 C), in the form of oxides, and (2) some Ti in the bulk forms clusters of various sizes with C, O, and/or N as nuclei

  9. Radon depth migration

    International Nuclear Information System (INIS)

    Hildebrand, S.T.; Carroll, R.J.

    1993-01-01

    A depth migration method is presented that used Radon-transformed common-source seismograms as input. It is shown that the Radon depth migration method can be extended to spatially varying velocity depth models by using asymptotic ray theory (ART) to construct wavefield continuation operators. These operators downward continue an incident receiver-array plane wave and an assumed point-source wavefield into the subsurface. The migration velocity model is constrain to have longer characteristic wavelengths than the dominant source wavelength such that the ART approximations for the continuation operators are valid. This method is used successfully to migrate two synthetic data examples: (1) a point diffractor, and (2) a dipping layer and syncline interface model. It is shown that the Radon migration method has a computational advantage over the standard Kirchhoff migration method in that fewer rays are computed in a main memory implementation

  10. Resolution limit of probe-forming systems with magnetic quadrupole lens triplets and quadruplets

    International Nuclear Information System (INIS)

    Ponomarev, A.G.; Melnik, K.I.; Miroshnichenko, V.I.; Storizhko, V.E.; Sulkio-Cleff, B.

    2003-01-01

    Over the past decade, in MeV ion beam microanalysis efforts to achieve a spatial resolution better than 0.1 μm with a beam current of ∼100 pA have been connected with microprobes of new generation where the probe is formed by means of separated magnetic quadrupole lens structures . However, as was pointed out in , no dramatic improvements in spatial resolution have been produced so far. For better understanding of the situation the authors carried out theoretical studies of multiparameter sets of probe-forming systems based on separated triplets and quadruplets of magnetic quadrupole lenses. Comparisons were made between the highest current values attained at different systems for a given beam spot size. The maximum parasitic sextupole and octupole field components were found whose contributions to spot broadening are tolerable. It is shown that the use of modern electrostatic accelerators and precision magnetic quadrupole lenses makes it possible to eliminate the effect of chromatic aberrations and second- and third-order parasitic aberrations resulting from distortions of the quadrupole lens symmetry. Therefore probe-forming systems with triplets and quadruplets of magnetic quadrupole lenses have a lower theoretical spatial resolution limit which is restricted mainly by intrinsic spherical third-order aberrations in state-of-the-art microprobes

  11. The AMEMIYA probe. Theoretical background

    International Nuclear Information System (INIS)

    Belitz, Hans Joahim; Althausen, Bernhard; Uehara, Kazuya; Amemiya, Hiroshi

    2010-01-01

    The present probe was developed in order to measure the temperature T i of positive ions in the scrape-off layer (SOL) of tokamak where T i is usually larger than the electron temperature Ti so that the presheath in front of the probe need not be considered and the ions reach the probe with the thermal velocity. The axis of the cylindrical probe is placed parallel to the magnetic field. The important parameter are L/a, the ratio of the length to the radius of the cylindrical probe and κ, the ratio of the probe radius to (π/4) 1/2 , where is the mean ion Larmor radius. The ion current densities to the side and the end surfaces are expressed by the double integral, which can give an analytical formula with respect to the value of κ. If two electrodes with different lengths are placed parallel to the magnetic field, the difference of current densities can be reduced to κ and hence to Ti. Some examples of the application of the probe to tokamaks, JFT-2M and Textor, are demonstrated. (author)

  12. Azobenzene-caged sulforhodamine dyes: a novel class of ‘turn-on’ reactive probes for hypoxic tumor cell imaging

    Science.gov (United States)

    Chevalier, Arnaud; Piao, Wen; Hanaoka, Kenjiro; Nagano, Tetsuo; Renard, Pierre-Yves; Romieu, Anthony

    2015-12-01

    New sulforhodamine-based fluorescent ‘turn-on’ probes have been developed for the direct imaging of cellular hypoxia. Rapid access to this novel class of water-soluble ‘azobenzene-caged’ fluorophores was made possible through an easily-implementable azo-coupling reaction between a fluorescent primary arylamine derived from a sulforhodamine 101 scaffold (named SR101-NaphtNH 2 ) and a tertiary aniline whose N-substituents are neutral, cationic, or zwitterionic. The detection mechanism is based on the bioreductive cleavage of the azo bond that restores strong far-red fluorescence (emission maximum at 625 nm) by regenerating the original sulforhodamine SR101-NaphtNH 2 . This valuable fluorogenic response was obtained for the three ‘smart’ probes studied in this work, as shown by an in vitro assay using rat liver microsomes placed under aerobic and then under hypoxic conditions. Most importantly, the probe namely SR101-NaphtNH 2 -Hyp-diMe was successfully applied for imaging the hypoxic status of tumor cells (A549 cells).

  13. A fully automated and scalable timing probe-based method for time alignment of the LabPET II scanners

    Science.gov (United States)

    Samson, Arnaud; Thibaudeau, Christian; Bouchard, Jonathan; Gaudin, Émilie; Paulin, Caroline; Lecomte, Roger; Fontaine, Réjean

    2018-05-01

    A fully automated time alignment method based on a positron timing probe was developed to correct the channel-to-channel coincidence time dispersion of the LabPET II avalanche photodiode-based positron emission tomography (PET) scanners. The timing probe was designed to directly detect positrons and generate an absolute time reference. The probe-to-channel coincidences are recorded and processed using firmware embedded in the scanner hardware to compute the time differences between detector channels. The time corrections are then applied in real-time to each event in every channel during PET data acquisition to align all coincidence time spectra, thus enhancing the scanner time resolution. When applied to the mouse version of the LabPET II scanner, the calibration of 6 144 channels was performed in less than 15 min and showed a 47% improvement on the overall time resolution of the scanner, decreasing from 7 ns to 3.7 ns full width at half maximum (FWHM).

  14. Computer modelling of eddy current probes

    International Nuclear Information System (INIS)

    Sullivan, S.P.

    1992-01-01

    Computer programs have been developed for modelling impedance and transmit-receive eddy current probes in two-dimensional axis-symmetric configurations. These programs, which are based on analytic equations, simulate bobbin probes in infinitely long tubes and surface probes on plates. They calculate probe signal due to uniform variations in conductor thickness, resistivity and permeability. These signals depend on probe design and frequency. A finite element numerical program has been procured to calculate magnetic permeability in non-linear ferromagnetic materials. Permeability values from these calculations can be incorporated into the above analytic programs to predict signals from eddy current probes with permanent magnets in ferromagnetic tubes. These programs were used to test various probe designs for new testing applications. Measurements of magnetic permeability in magnetically biased ferromagnetic materials have been performed by superimposing experimental signals, from special laboratory ET probes, on impedance plane diagrams calculated using these programs. (author). 3 refs., 2 figs

  15. Complementary Characterization of Cu(In,Ga)Se₂ Thin-Film Photovoltaic Cells Using Secondary Ion Mass Spectrometry, Auger Electron Spectroscopy, and Atom Probe Tomography.

    Science.gov (United States)

    Jang, Yun Jung; Lee, Jihye; Jeong, Jeung-Hyun; Lee, Kang-Bong; Kim, Donghwan; Lee, Yeonhee

    2018-05-01

    To enhance the conversion performance of solar cells, a quantitative and depth-resolved elemental analysis of photovoltaic thin films is required. In this study, we determined the average concentration of the major elements (Cu, In, Ga, and Se) in fabricated Cu(In,Ga)Se2 (CIGS) thin films, using inductively coupled plasma atomic emission spectroscopy, X-ray fluorescence, and wavelengthdispersive electron probe microanalysis. Depth profiling results for CIGS thin films with different cell efficiencies were obtained using secondary ion mass spectrometry and Auger electron spectroscopy to compare the atomic concentrations. Atom probe tomography, a characterization technique with sub-nanometer resolution, was used to obtain three-dimensional elemental mapping and the compositional distribution at the grain boundaries (GBs). GBs are identified by Na increment accompanied by Cu depletion and In enrichment. Segregation of Na atoms along the GB had a beneficial effect on cell performance. Comparative analyses of different CIGS absorber layers using various analytical techniques provide us with understanding of the compositional distributions and structures of high efficiency CIGS thin films in solar cells.

  16. Contamination-free sounding rocket Langmuir probe

    Science.gov (United States)

    Amatucci, W. E.; Schuck, P. W.; Walker, D. N.; Kintner, P. M.; Powell, S.; Holback, B.; Leonhardt, D.

    2001-04-01

    A technique for removing surface contaminants from a sounding rocket spherical Langmuir probe is presented. Contamination layers present on probe surfaces can skew the collected data, resulting in the incorrect determination of plasma parameters. Despite following the usual probe cleaning techniques that are used prior to a launch, the probe surface can become coated with layers of adsorbed neutral gas in less than a second when exposed to atmosphere. The laboratory tests reported here show that by heating the probe from the interior using a small halogen lamp, adsorbed neutral particles can be removed from the probe surface, allowing accurate plasma parameter measurements to be made.

  17. Correlation between hypocenter depth, antecedent precipitation and earthquake-induced landslide spatial distribution

    Science.gov (United States)

    Fukuoka, Hiroshi; Watanabe, Eisuke

    2017-04-01

    Since Keefer published the paper on earthquake magnitude and affected area, maximum epicentral/fault distance of induced landslide distribution in 1984, showing the envelope of plots, a lot of studies on this topic have been conducted. It has been generally supposed that landslides have been triggered by shallow quakes and more landslides are likely to occur with heavy rainfalls immediately before the quake. In order to confirm this, we have collected 22 case records of earthquake-induced landslide distribution in Japan and examined the effect of hypocenter depth and antecedent precipitation. Earthquake magnitude by JMA (Japan Meteorological Agency) of the cases are from 4.5 to 9.0. Analysis on hycpocenter depth showed the deeper quake cause wider distribution. Antecedent precipitation was evaluated using the Soil Water Index (SWI), which was developed by JMA for issuing landslide alert. We could not find meaningful correlation between SWI and the earthquake-induced landslide distribution. Additionally, we found that smaller minimum size of collected landslides results in wider distribution especially between 1,000 to 100,000 m2.

  18. Waves of visibility: probing the depth of inter-ocular suppression with transient and sustained targets

    Directory of Open Access Journals (Sweden)

    Lisandro eKaunitz

    2014-07-01

    Full Text Available In order to study non-conscious visual processing, researchers render otherwise consciously perceived images into invisible stimuli. Through the years, several psychophysical techniques have been developed for this purpose. Yet the comparison of experimental results across techniques remains a difficult task as the depth of suppression depends on the interactions between the type of stimuli and the suppression methods employed. This poses a limit to the inferences that researchers make about the extent of non-conscious processes. We investigated the mechanisms underlying inter-ocular suppression during continuous flash suppression (CFS and dichoptic visual masking using a transient onset target stimulus and a variety of stimulus / mask temporal manipulations. We show that target duration, timing of target onset, and mask frequency are key aspects of inter-ocular suppression during CFS with transient targets. The differences between our results and sustained target CFS studies suggest that two distinct mechanisms are involved in the detection of transient and prolonged target stimuli during CFS. Our results provide insight into the dynamics of CFS together with evidence for similarities between transient target CFS and dichoptic visual masking.

  19. Depth sensitivity and source-detector separations for near infrared spectroscopy based on the Colin27 brain template.

    Directory of Open Access Journals (Sweden)

    Gary E Strangman

    Full Text Available Understanding the spatial and depth sensitivity of non-invasive near-infrared spectroscopy (NIRS measurements to brain tissue-i.e., near-infrared neuromonitoring (NIN - is essential for designing experiments as well as interpreting research findings. However, a thorough characterization of such sensitivity in realistic head models has remained unavailable. In this study, we conducted 3,555 Monte Carlo (MC simulations to densely cover the scalp of a well-characterized, adult male template brain (Colin27. We sought to evaluate: (i the spatial sensitivity profile of NIRS to brain tissue as a function of source-detector separation, (ii the NIRS sensitivity to brain tissue as a function of depth in this realistic and complex head model, and (iii the effect of NIRS instrument sensitivity on detecting brain activation. We found that increasing the source-detector (SD separation from 20 to 65 mm provides monotonic increases in sensitivity to brain tissue. For every 10 mm increase in SD separation (up to ~45 mm, sensitivity to gray matter increased an additional 4%. Our analyses also demonstrate that sensitivity in depth (S decreases exponentially, with a "rule-of-thumb" formula S=0.75*0.85(depth. Thus, while the depth sensitivity of NIRS is not strictly limited, NIN signals in adult humans are strongly biased towards the outermost 10-15 mm of intracranial space. These general results, along with the detailed quantitation of sensitivity estimates around the head, can provide detailed guidance for interpreting the likely sources of NIRS signals, as well as help NIRS investigators design and plan better NIRS experiments, head probes and instruments.

  20. Depth-resolved ballistic imaging in a low-depth-of-field optical Kerr gated imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Yipeng; Tan, Wenjiang, E-mail: tanwenjiang@mail.xjtu.edu.cn; Si, Jinhai; Ren, YuHu; Xu, Shichao; Hou, Xun [Key Laboratory for Physical Electronics and Devices of the Ministry of Education and Shaanxi Key Lab of Information Photonic Technique, School of Electronics and Information Engineering, Xi' an Jiaotong University, Xianning-xilu 28, Xi' an 710049 (China); Tong, Junyi [Departments of Applied Physics, Xi' an University of Technology, Xi' an 710048 (China)

    2016-09-07

    We demonstrate depth-resolved imaging in a ballistic imaging system, in which a heterodyned femtosecond optical Kerr gate is introduced to extract useful imaging photons for detecting an object hidden in turbid media and a compound lens is proposed to ensure both the depth-resolved imaging capability and the long working distance. Two objects of about 15-μm widths hidden in a polystyrene-sphere suspension have been successfully imaged with approximately 600-μm depth resolution. Modulation-transfer-function curves with the object in and away from the object plane have also been measured to confirm the depth-resolved imaging capability of the low-depth-of-field (low-DOF) ballistic imaging system. This imaging approach shows potential for application in research of the internal structure of highly scattering fuel spray.

  1. Probing Sub-GeV Dark Matter with Conventional Detectors

    DEFF Research Database (Denmark)

    Kouvaris, Chris; Pradler, Josef

    2017-01-01

    The direct detection of dark matter particles with mass below the GeV scale is hampered by soft nuclear recoil energies and finite detector thresholds. For a given maximum relative velocity, the kinematics of elastic dark matter nucleus scattering sets a principal limit on detectability. Here, we...... propose to bypass the kinematic limitations by considering the inelastic channel of photon emission from bremsstrahlung in the nuclear recoil. Our proposed method allows us to set the first limits on dark matter below 500 MeV in the plane of dark matter mass and cross section with nucleons. In situations...... where a dark-matter-electron coupling is suppressed, bremsstrahlung may constitute the only path to probe low-mass dark matter awaiting new detector technologies with lowered recoil energy thresholds....

  2. Dynamic pressure probe response tests for robust measurements in periodic flows close to probe resonating frequency

    Science.gov (United States)

    Ceyhun Şahin, Fatma; Schiffmann, Jürg

    2018-02-01

    A single-hole probe was designed to measure steady and periodic flows with high fluctuation amplitudes and with minimal flow intrusion. Because of its high aspect ratio, estimations showed that the probe resonates at a frequency two orders of magnitude lower than the fast response sensor cut-off frequencies. The high fluctuation amplitudes cause a non-linear behavior of the probe and available models are neither adequate for a quantitative estimation of the resonating frequencies nor for predicting the system damping. Instead, a non-linear data correction procedure based on individual transfer functions defined for each harmonic contribution is introduced for pneumatic probes that allows to extend their operating range beyond the resonating frequencies and linear dynamics. This data correction procedure was assessed on a miniature single-hole probe of 0.35 mm inner diameter which was designed to measure flow speed and direction. For the reliable use of such a probe in periodic flows, its frequency response was reproduced with a siren disk, which allows exciting the probe up to 10 kHz with peak-to-peak amplitudes ranging between 20%-170% of the absolute mean pressure. The effect of the probe interior design on the phase lag and amplitude distortion in periodic flow measurements was investigated on probes with similar inner diameters and different lengths or similar aspect ratios (L/D) and different total interior volumes. The results suggest that while the tube length consistently sets the resonance frequency, the internal total volume affects the non-linear dynamic response in terms of varying gain functions. A detailed analysis of the introduced calibration methodology shows that the goodness of the reconstructed data compared to the reference data is above 75% for fundamental frequencies up to twice the probe resonance frequency. The results clearly suggest that the introduced procedure is adequate to capture non-linear pneumatic probe dynamics and to

  3. Maximum Acceleration Recording Circuit

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Coarsely digitized maximum levels recorded in blown fuses. Circuit feeds power to accelerometer and makes nonvolatile record of maximum level to which output of accelerometer rises during measurement interval. In comparison with inertia-type single-preset-trip-point mechanical maximum-acceleration-recording devices, circuit weighs less, occupies less space, and records accelerations within narrower bands of uncertainty. In comparison with prior electronic data-acquisition systems designed for same purpose, circuit simpler, less bulky, consumes less power, costs and analysis of data recorded in magnetic or electronic memory devices. Circuit used, for example, to record accelerations to which commodities subjected during transportation on trucks.

  4. A Plasmonic Gold Nanostar Theranostic Probe for In Vivo Tumor Imaging and Photothermal Therapy

    Science.gov (United States)

    Liu, Yang; Ashton, Jeffrey R.; Moding, Everett J.; Yuan, Hsiangkuo; Register, Janna K.; Fales, Andrew M.; Choi, Jaeyeon; Whitley, Melodi J.; Zhao, Xiaoguang; Qi, Yi; Ma, Yan; Vaidyanathan, Ganesan; Zalutsky, Michael R.; Kirsch, David G.; Badea, Cristian T.; Vo-Dinh, Tuan

    2015-01-01

    Nanomedicine has attracted increasing attention in recent years, because it offers great promise to provide personalized diagnostics and therapy with improved treatment efficacy and specificity. In this study, we developed a gold nanostar (GNS) probe for multi-modality theranostics including surface-enhanced Raman scattering (SERS) detection, x-ray computed tomography (CT), two-photon luminescence (TPL) imaging, and photothermal therapy (PTT). We performed radiolabeling, as well as CT and optical imaging, to investigate the GNS probe's biodistribution and intratumoral uptake at both macroscopic and microscopic scales. We also characterized the performance of the GNS nanoprobe for in vitro photothermal heating and in vivo photothermal ablation of primary sarcomas in mice. The results showed that 30-nm GNS have higher tumor uptake, as well as deeper penetration into tumor interstitial space compared to 60-nm GNS. In addition, we found that a higher injection dose of GNS can increase the percentage of tumor uptake. We also demonstrated the GNS probe's superior photothermal conversion efficiency with a highly concentrated heating effect due to a tip-enhanced plasmonic effect. In vivo photothermal therapy with a near-infrared (NIR) laser under the maximum permissible exposure (MPE) led to ablation of aggressive tumors containing GNS, but had no effect in the absence of GNS. This multifunctional GNS probe has the potential to be used for in vivo biosensing, preoperative CT imaging, intraoperative detection with optical methods (SERS and TPL), as well as image-guided photothermal therapy. PMID:26155311

  5. Acoustic field of focusing phased array probe and the scanning system

    International Nuclear Information System (INIS)

    Murai, J.; Miura, S.; Ida, T.; Shiraiwa, T.; Miya, T.

    1997-01-01

    Acoustic field of a point focusing cylindrical linear array probe, in which focusing in the axial direction of cylinder is done by the phased linear array and focusing in the orthogonal direction is done geometrically, was studied by numerical calculation and an optimum design of phased array probe for focusing has been obtained. In generally speaking, the beam width at focus point decreases with decrease of width of each transducer element and with increase of synthetic aperture made by total elements. If the number of total array elements excited as one pulse is limited, the above conditions are contradicted. Thus, an optimum element width exists for the best focusing. On the above consideration, we can get focusing ability of phased array nearly as same as geometrical focusing. A developed transducer is a linear array of polymer piezoelectric material of cylindrical shape, of which radius is from 50 mm to 75 mm. The frequency is 10 Mhz and the beam width of 0.5 mm (depending on aperture) in the orthogonal direction to the cylinder axis and 0.7 mm width in the cylinder axis (phased array focusing) have been obtained. A delay circuit for exciting the transducer was newly designed to give maximum performance to the array regarding to accuracy, stability, easy control and etc. A c-scan ultrasonic testing system equipped with this transducer has sixteen times inspection speed compared to the single probe instrument.

  6. Neutron spectra unfolding with maximum entropy and maximum likelihood

    International Nuclear Information System (INIS)

    Itoh, Shikoh; Tsunoda, Toshiharu

    1989-01-01

    A new unfolding theory has been established on the basis of the maximum entropy principle and the maximum likelihood method. This theory correctly embodies the Poisson statistics of neutron detection, and always brings a positive solution over the whole energy range. Moreover, the theory unifies both problems of overdetermined and of underdetermined. For the latter, the ambiguity in assigning a prior probability, i.e. the initial guess in the Bayesian sense, has become extinct by virtue of the principle. An approximate expression of the covariance matrix for the resultant spectra is also presented. An efficient algorithm to solve the nonlinear system, which appears in the present study, has been established. Results of computer simulation showed the effectiveness of the present theory. (author)

  7. Maximum Power from a Solar Panel

    Directory of Open Access Journals (Sweden)

    Michael Miller

    2010-01-01

    Full Text Available Solar energy has become a promising alternative to conventional fossil fuel sources. Solar panels are used to collect solar radiation and convert it into electricity. One of the techniques used to maximize the effectiveness of this energy alternative is to maximize the power output of the solar collector. In this project the maximum power is calculated by determining the voltage and the current of maximum power. These quantities are determined by finding the maximum value for the equation for power using differentiation. After the maximum values are found for each time of day, each individual quantity, voltage of maximum power, current of maximum power, and maximum power is plotted as a function of the time of day.

  8. NATO Advanced Study Institute on Scanning Probe Microscopy : Characterization, Nanofabrication and Device Application of Functional Materials

    CERN Document Server

    Vilarinho, Paula Maria; Kingon, Angus; Scanning Probe Microscopy : Characterization, Nanofabrication and Device Application of Functional Materials

    2005-01-01

    As the characteristic dimensions of electronic devices continue to shrink, the ability to characterize their electronic properties at the nanometer scale has come to be of outstanding importance. In this sense, Scanning Probe Microscopy (SPM) is becoming an indispensable tool, playing a key role in nanoscience and nanotechnology. SPM is opening new opportunities to measure semiconductor electronic properties with unprecedented spatial resolution. SPM is being successfully applied for nanoscale characterization of ferroelectric thin films. In the area of functional molecular materials it is being used as a probe to contact molecular structures in order to characterize their electrical properties, as a manipulator to assemble nanoparticles and nanotubes into simple devices, and as a tool to pattern molecular nanostructures. This book provides in-depth information on new and emerging applications of SPM to the field of materials science, namely in the areas of characterisation, device application and nanofabrica...

  9. [The influence of probe geometry on the sensitivity of tissue oximeter using near infra-red spectroscopy].

    Science.gov (United States)

    Wang, F; Ding, H; Lin, F

    2000-08-01

    Based on the modified Lambert-Beer law under scattering media, near infra-red spectroscopy tissue oximeter measures the changes of absorber concentrations (such as oxy-hemoglobin, deoxy-hemoglobin, cytochrome aa3). This is made possible by recording the optical density change under different physiological status. This paper describes the average penetration depth, average photon path-length and spatial sensitive profile in multi-layered tissue model using Monte-Carlo method. The result shows the probe geometry of the sensor, which is the separation between the light source and the detector, has a great influence on the sensitivity of measurement. Increasing this separation properly allows the improvement of the sensitivity of measurement and the increase of the probability of looking at oxygenation deep under the surface tissue. But this improvement is limited by the decrease of signal-noise ratio. Optimum probe spacing should be estimated for special tissue structure.

  10. Self Focusing SIMS: Probing thin film composition in very confined volumes

    International Nuclear Information System (INIS)

    Franquet, Alexis; Douhard, Bastien; Melkonyan, Davit; Favia, Paola; Conard, Thierry; Vandervorst, Wilfried

    2016-01-01

    that all cluster constituents originate from the same collision cascade and are emitted in close proximity (<0.5 nm). As such, the composition information becomes confined (i.e. self focused) to the areas where all constituents are simultaneously present. The examples shown in this work are based on SiGe compounds and demonstrate that it becomes feasible to determine the composition of thin films in ultra narrow trenches (down to 20 nm in width) with good accuracy and sensitivity. Whereas for the case where the probing beam is focused to a dimension smaller than the width of the structure, the analyzed volume/data point becomes very small (< a few tens of nm 3 ), the simultaneous detection of many atoms from the multiple structures in the Self Focusing SIMS approach, represents effectively a much larger volume providing the abundant sensitivity as the analyzed area is now increased up to 100 μm 2 . On the other hand, the minimum depth probed (in each trench) is still governed by the depth resolution of SIMS, hence it is similar to the one encountered in SIMS experiments performed on blanket films. This can be as small as 1–2 nm/dec and is only limited by the energy of the sputter beam.

  11. Surface analysis and depth profiling of corrosion products formed in lead pipes used to supply low alkalinity drinking water.

    Science.gov (United States)

    Davidson, C M; Peters, N J; Britton, A; Brady, L; Gardiner, P H E; Lewis, B D

    2004-01-01

    Modern analytical techniques have been applied to investigate the nature of lead pipe corrosion products formed in pH adjusted, orthophosphate-treated, low alkalinity water, under supply conditions. Depth profiling and surface analysis have been carried out on pipe samples obtained from the water distribution system in Glasgow, Scotland, UK. X-ray diffraction spectrometry identified basic lead carbonate, lead oxide and lead phosphate as the principal components. Scanning electron microscopy/energy-dispersive x-ray spectrometry revealed the crystalline structure within the corrosion product and also showed spatial correlations existed between calcium, iron, lead, oxygen and phosphorus. Elemental profiling, conducted by means of secondary ion mass spectrometry (SIMS) and secondary neutrals mass spectrometry (SNMS) indicated that the corrosion product was not uniform with depth. However, no clear stratification was apparent. Indeed, counts obtained for carbonate, phosphate and oxide were well correlated within the depth range probed by SIMS. SNMS showed relationships existed between carbon, calcium, iron, and phosphorus within the bulk of the scale, as well as at the surface. SIMS imaging confirmed the relationship between calcium and lead and suggested there might also be an association between chloride and phosphorus.

  12. Updating default depths in the ISC bulletin

    Science.gov (United States)

    Bolton, Maiclaire K.; Storchak, Dmitry A.; Harris, James

    2006-09-01

    The International Seismological Centre (ISC) publishes the definitive global bulletin of earthquake locations. In the ISC bulletin, we aim to obtain a free depth, but often this is not possible. Subsequently, the first option is to obtain a depth derived from depth phases. If depth phases are not available, we then use the reported depth from a reputable local agency. Finally, as a last resort, we set a default depth. In the past, common depths of 10, 33, or multiples of 50 km have been assigned. Assigning a more meaningful default depth, specific to a seismic region will increase the consistency of earthquake locations within the ISC bulletin and allow the ISC to publish better positions and magnitude estimates. It will also improve the association of reported secondary arrivals to corresponding seismic events. We aim to produce a global set of default depths, based on a typical depth for each area, from well-constrained events in the ISC bulletin or where depth could be constrained using a consistent set of depth phase arrivals provided by a number of different reporters. In certain areas, we must resort to using other assumptions. For these cases, we use a global crustal model (Crust2.0) to set default depths to half the thickness of the crust.

  13. Pulse shape discrimination and classification methods for continuous depth of interaction encoding PET detectors

    International Nuclear Information System (INIS)

    Roncali, Emilie; Phipps, Jennifer E; Marcu, Laura; Cherry, Simon R

    2012-01-01

    In previous work we demonstrated the potential of positron emission tomography (PET) detectors with depth-of-interaction (DOI) encoding capability based on phosphor-coated crystals. A DOI resolution of 8 mm full-width at half-maximum was obtained for 20 mm long scintillator crystals using a delayed charge integration linear regression method (DCI-LR). Phosphor-coated crystals modify the pulse shape to allow continuous DOI information determination, but the relationship between pulse shape and DOI is complex. We are therefore interested in developing a sensitive and robust method to estimate the DOI. Here, linear discriminant analysis (LDA) was implemented to classify the events based on information extracted from the pulse shape. Pulses were acquired with 2×2×20 mm 3 phosphor-coated crystals at five irradiation depths and characterized by their DCI values or Laguerre coefficients. These coefficients were obtained by expanding the pulses on a Laguerre basis set and constituted a unique signature for each pulse. The DOI of individual events was predicted using LDA based on Laguerre coefficients (Laguerre-LDA) or DCI values (DCI-LDA) as discriminant features. Predicted DOIs were compared to true irradiation depths. Laguerre-LDA showed higher sensitivity and accuracy than DCI-LDA and DCI-LR and was also more robust to predict the DOI of pulses with higher statistical noise due to low light levels (interaction depths further from the photodetector face). This indicates that Laguerre-LDA may be more suitable to DOI estimation in smaller crystals where lower collected light levels are expected. This novel approach is promising for calculating DOI using pulse shape discrimination in single-ended readout depth-encoding PET detectors. (paper)

  14. Plasma diagnostics by electron guns and electric field probes on ISEE-1

    International Nuclear Information System (INIS)

    Pedersen, A.

    1982-01-01

    The use of electron guns to control the potential of a satellite with conductive surfaces is discussed with reference to the results of the ISEE-1 satellite experiment. The two electron guns carried by the satellite can emit electrons with energies up to 48 eV, and the emitted electron current has a maximum value of 0.5-1.0 mA. The satellite potential, with or without gun operation, can be measured with reference to one or two spherical electric field probes positioned on booms at a distance of 36 m from the satellite. The probes are biased with a negative current from a high-impedance source to be slightly positive (0.5-1.0 V) relative to the plasma, and the spacecraft is normally several volts more positive and can be further positively charged by operating the electron gun. Plasma diagnostics can be carried out by appropriate sweeps of gun currents and energy of emitted electrons to obtain information about density and characteristic energy of ambient electrons. 9 references

  15. Simplicial band depth for multivariate functional data

    KAUST Repository

    López-Pintado, Sara

    2014-03-05

    We propose notions of simplicial band depth for multivariate functional data that extend the univariate functional band depth. The proposed simplicial band depths provide simple and natural criteria to measure the centrality of a trajectory within a sample of curves. Based on these depths, a sample of multivariate curves can be ordered from the center outward and order statistics can be defined. Properties of the proposed depths, such as invariance and consistency, can be established. A simulation study shows the robustness of this new definition of depth and the advantages of using a multivariate depth versus the marginal depths for detecting outliers. Real data examples from growth curves and signature data are used to illustrate the performance and usefulness of the proposed depths. © 2014 Springer-Verlag Berlin Heidelberg.

  16. Real-time lossless compression of depth streams

    KAUST Repository

    Schneider, Jens

    2017-08-17

    Various examples are provided for lossless compression of data streams. In one example, a Z-lossless (ZLS) compression method includes generating compacted depth information by condensing information of a depth image and a compressed binary representation of the depth image using histogram compaction and decorrelating the compacted depth information to produce bitplane slicing of residuals by spatial prediction. In another example, an apparatus includes imaging circuitry that can capture one or more depth images and processing circuitry that can generate compacted depth information by condensing information of a captured depth image and a compressed binary representation of the captured depth image using histogram compaction; decorrelate the compacted depth information to produce bitplane slicing of residuals by spatial prediction; and generate an output stream based upon the bitplane slicing.

  17. Real-time lossless compression of depth streams

    KAUST Repository

    Schneider, Jens

    2017-01-01

    Various examples are provided for lossless compression of data streams. In one example, a Z-lossless (ZLS) compression method includes generating compacted depth information by condensing information of a depth image and a compressed binary representation of the depth image using histogram compaction and decorrelating the compacted depth information to produce bitplane slicing of residuals by spatial prediction. In another example, an apparatus includes imaging circuitry that can capture one or more depth images and processing circuitry that can generate compacted depth information by condensing information of a captured depth image and a compressed binary representation of the captured depth image using histogram compaction; decorrelate the compacted depth information to produce bitplane slicing of residuals by spatial prediction; and generate an output stream based upon the bitplane slicing.

  18. Development of Touch Probing System Using a Fiber Stylus

    Directory of Open Access Journals (Sweden)

    Hiroshi Murakami

    2016-08-01

    Full Text Available This paper presents a system that can be used for micro-hole measurement; the system comprises an optical fiber stylus that is 5 µm in diameter. The stylus deflects when it comes into contact with the measured surface; this deflection is measured optically. In this study, the design parameters of the optical system are determined using a ray-tracing method, and a prototype of the probing system is fabricated to verify ray-tracing simulation results; furthermore, the performance of the system is evaluated experimentally. The results show that the design parameters of this system can be determined using ray-tracing; the resolution of the measurement system using this shaft was approximately 3 nm, and the practicality of this system was confirmed by measuring the shape of a micro-hole 100 µm in diameter and 475 µm in depth.

  19. Human MLPA Probe Design (H-MAPD: a probe design tool for both electrophoresis-based and bead-coupled human multiplex ligation-dependent probe amplification assays

    Directory of Open Access Journals (Sweden)

    Hatchwell Eli

    2008-09-01

    Full Text Available Abstract Background Multiplex ligation-dependent probe amplification (MLPA is an efficient and reliable technique for gene dosage analysis. Currently MLPA can be conducted on two platforms: traditional electrophoresis-based, and FlexMAP bead-coupled. Since its introduction in 2002, MLPA has been rapidly adopted in both clinical and research situations. However, MLPA probe design is a time consuming process requiring many steps that address multiple criteria. There exist only one or two commercial software packages for traditional electrophoresis-based MLPA probe design. To our knowledge, no software is yet available that performs bead-coupled MLPA probe design. Results We have developed H-MAPD, a web-based tool that automates the generation and selection of probes for human genomic MLPA. The software performs physical-chemical property tests using UNAFold software, and uniqueness tests using the UCSC genome browser. H-MAPD supports both traditional electrophoresis-based assays, as well as FlexMAP bead-coupled MLPA. Conclusion H-MAPD greatly reduces the efforts for human genomic MLPA probe design. The software is written in Perl-CGI, hosted on a Linux server, and is freely available to non-commercial users.

  20. Mobile Probes in Mobile Learning

    DEFF Research Database (Denmark)

    Ørngreen, Rikke; Blomhøj, Ulla; Duvaa, Uffe

    In this paper experiences from using mobile probes in educational design of a mobile learning application is presented. The probing process stems from the cultural probe method, and was influenced by qualitative interview and inquiry approaches. In the project, the mobile phone was not only acting...... as an agent for acquiring empirical data (as the situation in hitherto mobile probe settings) but was also the technological medium for which data should say something about (mobile learning). Consequently, not only the content of the data but also the ways in which data was delivered and handled, provided...... a valuable dimension for investigating mobile use. The data was collected at the same time as design activities took place and the collective data was analysed based on user experience goals and cognitive processes from interaction design and mobile learning. The mobile probe increased the knowledge base...

  1. Neutron-based portable drug probe

    International Nuclear Information System (INIS)

    Womble, P. C.; Vourvopoulos, G.; Ball Howard, J.; Paschal, J.

    1999-01-01

    Based on previous measurements, a probe prototype for contraband detection utilizing the neutron technique of Pulsed Fast-Thermal Neutron Analysis (PFTNA) is being constructed. The prototype weighs less than 45 kg and is composed of a probe (5 cm diameter), a power pack and a data acquisition and display system. The probe is designed to be inserted in confined spaces such as the boiler of a ship or a tanker truck filled with liquid. The probe provides information on a) the elemental content, and b) the density variations of the interrogated object. By measuring elemental content, the probe can differentiate between innocuous materials and drugs. Density variations can be found through fast neutron transmission. In all cases, hidden drugs are identified through the measurement of the elemental content of the object, and the comparison of expected and measured elemental ratios

  2. Adjustable Pitot Probe

    Science.gov (United States)

    Ashby, George C., Jr.; Robbins, W. Eugene; Horsley, Lewis A.

    1991-01-01

    Probe readily positionable in core of uniform flow in hypersonic wind tunnel. Formed of pair of mating cylindrical housings: transducer housing and pitot-tube housing. Pitot tube supported by adjustable wedge fairing attached to top of pitot-tube housing with semicircular foot. Probe adjusted both radially and circumferentially. In addition, pressure-sensing transducer cooled internally by water or other cooling fluid passing through annulus of cooling system.

  3. A Conjugate of Pentamethine Cyanine and 18F as a Positron Emission Tomography/Near-Infrared Fluorescence Probe for Multimodality Tumor Imaging

    Directory of Open Access Journals (Sweden)

    Fei-Fei An

    2017-06-01

    Full Text Available The novel synthesis of a dual-modality, pentamethine cyanine (Cy5 fluorescent, 18F positron emission tomography (PET imaging probe is reported. The probe shows a large extinction coefficient and large quantum yield in the biologically transparent, near-infrared window (650–900 nm for in vivo fluorescent imaging. This fluorophore bears the isotope, 18F, giving a 18F-PET/near-infrared fluorescent (NIRF, bi-modal imaging probe, that combines the long-term stability of NIRF and the unlimited penetration depth of PET imaging. The bi-modal probe is labeled with 18F in a quick, one-step reaction, which is important in working with the rapid decay of 18F. The bi-modal probe bears a free carboxyl group, highlighting a PET/NIRF synthon that can be conjugated onto many advanced biomolecules for biomarker-specific in vivo dual-modal PET/NIR tumor imaging, confocal histology, and utility in multi-fluorophore, fluorescence-guided surgery. Its potential in vivo biocompatibility is explored in a quick proof-of-principal in vivo study. The dye is delivered to A549 xenograft flank-tumors to generate PET and NIRF signals at the tumor site. The tumor distribution is confirmed in ex vivo gamma counting and imaging. Pentamethine cyanine (Cy5 has the ability to preferentially accumulate in tumor xenografts. We substitute the PET/NIRF probe for Cy5, and explore this phenomenon.

  4. Correction of fluorescence for depth-specific optical and vascular properties using reflectance and differential path-length spectroscopy during PDT

    Science.gov (United States)

    van Zaane, F.; Middelburg, T. A.; de Bruijn, H. S.; van der Ploeg-van den Heuvel, A.; de Haas, E. R. M.; Sterenborg, H. J. C. M.; Neumann, H. A. M.; Robinson, D. J.

    2009-06-01

    Introduction: The rate of PpIX fluorescence photobleaching is routinely used as a dose metric for ALA-PDT. Diffuse reflection spectroscopy is often used to account for variations in tissue optical properties at the photosensitizer excitation and emission bands. It can be used to quantify changes in vascular parameters, such as blood volume fraction and saturation, and can aid understanding of tissue response to PDT. The volume and(/or) depth over which these signals are acquired are critical. The aim of this study is to use quantitative reflectance spectroscopy (DPS) to correct fluorescence for changes in tissue optical properties and monitor PDT. Materials & Methods: ALA was topically applied to hairless mice skin and the incubated spot was treated with PDT according to fractionated illumination schemes. DPS measurements of vascular parameters and optical properties were performed directly before and after illumination. Both the differential signal, delivery-and-collection-fiber signal and the collection fiber signal, which all probe different measurement volumes, are analyzed. Results & Conclusions: Analysis of DPS measurements shows that at the depth where most fluorescence originates, there is almost no blood present. During PDT vascular parameters at this depth stay constant. In more oxygenated layers of the tissue, the optical properties do change during PDT, suggesting that only a small part of PpIX fluorescence originates from the interesting depths where vascular response occurs. Correcting fluorescence emission spectra for optical changes at specific depths and not for the total of changes in a larger volume, as is usually done now, can improve PpIX photobleaching based treatment monitoring.

  5. Novel PET and Near Infrared Imaging Probes for the Specific Detection of Bacterial Infections Associated With Cardiac Devices.

    Science.gov (United States)

    Takemiya, Kiyoko; Ning, Xinghai; Seo, Wonewoo; Wang, Xiaojian; Mohammad, Rafi; Joseph, Giji; Titterington, Jane S; Kraft, Colleen S; Nye, Jonathan A; Murthy, Niren; Goodman, Mark M; Taylor, W Robert

    2018-04-13

    The aim of this study was to develop imaging agents to detect early stage infections in implantable cardiac devices. Bacteria ingest maltodextrins through the specific maltodextrin transporter. We developed probes conjugated with either a fluorescent dye (maltohexaose fluorescent dye probe [MDP]) or a F-18 (F18 fluoromaltohexaose) and determined their usefulness in a model of infections associated with implanted cardiac devices. Stainless steel mock-ups of medical devices were implanted subcutaneously in rats. On post-operative day 4, animals were injected with either Staphylococcus aureus around the mock-ups to induce a relatively mild infection or oil of turpentine to induce noninfectious inflammation. Animals with a sterile implant were used as control subjects. On post-operative day 6, either the MDP or F18 fluoromaltohexaose was injected intravenously, and the animals were scanned with the appropriate imaging device. Additional positron emission tomography imaging studies were performed with F18-fluorodeoxyglucose as a comparison of the specificity of our probes (n = 5 to 9 per group). The accumulation of the MDP in the infected rats was significantly increased at 1 h after injection when compared with the control and noninfectious inflammation groups (intensity ratio 1.54 ± 0.07 vs. 1.26 ± 0.04 and 1.20 ± 0.05, respectively; p F18 fluoromaltohexaose and F18 fluorodeoxyglucose significantly accumulated in the infected area 30 min after the injection (maximum standard uptake value ratio 4.43 ± 0.30 and 4.87 ± 0.28, respectively). In control rats, there was no accumulation of imaging probes near the device. In the noninfectious inflammation rats, no significant accumulation was observed with F18 fluoromaltohexaose, but F18 fluorodeoxyglucose accumulated in the mock-up area (maximum standard uptake value 2.53 ± 0.39 vs. 4.74 ± 0.46, respectively; p < 0.05). Our results indicate that maltohexaose-based imaging probes are potentially useful for the

  6. Evaporation from bare ground with different water-table depths based on an in-situ experiment in Ordos Plateau, China

    Science.gov (United States)

    Zhang, Zaiyong; Wang, Wenke; Wang, Zhoufeng; Chen, Li; Gong, Chengcheng

    2018-03-01

    The dynamic processes of ground evaporation are complex and are related to a multitude of factors such as meteorological influences, water-table depth, and materials in the unsaturated zone. To investigate ground evaporation from a homogeneous unsaturated zone, an in-situ experiment was conducted in Ordos Plateau of China. Two water-table depths were chosen to explore the water movement in the unsaturated zone and ground evaporation. Based on the experimental and calculated results, it was revealed that (1) bare ground evaporation is an atmospheric-limited stage for the case of water-table depth being close to the capillary height; (2) the bare ground evaporation is a water-storage-limited stage for the case of water-table depth being beyond the capillary height; (3) groundwater has little effect on ground-surface evaporation when the water depth is larger than the capillary height; and (4) ground evaporation is greater at nighttime than that during the daytime; and (5) a liquid-vapor interaction zone at nearly 20 cm depth is found, in which there exists a downward vapor flux on sunny days, leading to an increasing trend of soil moisture between 09:00 to 17:00; the maximum value is reached at midday. The results of this investigation are useful to further understand the dynamic processes of ground evaporation in arid areas.

  7. The Antartic Ice Borehole Probe

    Science.gov (United States)

    Behar, A.; Carsey, F.; Lane, A.; Engelhardt, H.

    2000-01-01

    The Antartic Ice Borehole Probe mission is a glaciological investigation, scheduled for November 2000-2001, that will place a probe in a hot-water drilled hole in the West Antartic ice sheet. The objectives of the probe are to observe ice-bed interactions with a downward looking camera, and ice inclusions and structure, including hypothesized ice accretion, with a side-looking camera.

  8. Improving the Curie depth estimation through optimizing the spectral block dimensions of the aeromagnetic data in the Sabalan geothermal field

    Science.gov (United States)

    Akbar, Somaieh; Fathianpour, Nader

    2016-12-01

    The Curie point depth is of great importance in characterizing geothermal resources. In this study, the Curie iso-depth map was provided using the well-known method of dividing the aeromagnetic dataset into overlapping blocks and analyzing the power spectral density of each block separately. Determining the optimum block dimension is vital in improving the resolution and accuracy of estimating Curie point depth. To investigate the relation between the optimal block size and power spectral density, a forward magnetic modeling was implemented on an artificial prismatic body with specified characteristics. The top, centroid, and bottom depths of the body were estimated by the spectral analysis method for different block dimensions. The result showed that the optimal block size could be considered as the smallest possible block size whose corresponding power spectrum represents an absolute maximum in small wavenumbers. The Curie depth map of the Sabalan geothermal field and its surrounding areas, in the northwestern Iran, was produced using a grid of 37 blocks with different dimensions from 10 × 10 to 50 × 50 km2, which showed at least 50% overlapping with adjacent blocks. The Curie point depth was estimated in the range of 5 to 21 km. The promising areas with the Curie point depths less than 8.5 km are located around Mountain Sabalan encompassing more than 90% of known geothermal resources in the study area. Moreover, the Curie point depth estimated by the improved spectral analysis is in good agreement with the depth calculated from the thermal gradient data measured in one of the exploratory wells in the region.

  9. Quantitative Auger depth profiling of LPCVD and PECVD silicon nitride films

    International Nuclear Information System (INIS)

    Keim, E.G.; Aite, K.

    1989-01-01

    Thin silicon nitride films (100-210 nm) with refractive indices varying from 1.90 to 2.10 were deposited on silicon substrates by low pressure chemical vapour deposition (LPCVD) and plasma enhanced chemical vapour deposition (PECVD). Rutherford backscattering spectrometry (RBS), ellipsometry, surface profiling measurements and Auger electron spectroscopy (AES) in combination with Ar + sputtering were used to characterize these films. We have found that the use of (p-p)heights of the Si LVV and N KLL Auger transitions in the first derivative of the energy distribution (dN(E)/dE) leads to an accurate determination of the silicon nitride composition in Auger depth profiles over a wide range of atomic Si/N ratios. Moreover, we have shown that the Si KLL Auger transition, generally considered to be a better probe than the low energy Si LVV Auger transition in determining the chemical composition of silicon nitride layers, leads to deviating results. (orig.)

  10. Layered compression for high-precision depth data.

    Science.gov (United States)

    Miao, Dan; Fu, Jingjing; Lu, Yan; Li, Shipeng; Chen, Chang Wen

    2015-12-01

    With the development of depth data acquisition technologies, access to high-precision depth with more than 8-b depths has become much easier and determining how to efficiently represent and compress high-precision depth is essential for practical depth storage and transmission systems. In this paper, we propose a layered high-precision depth compression framework based on an 8-b image/video encoder to achieve efficient compression with low complexity. Within this framework, considering the characteristics of the high-precision depth, a depth map is partitioned into two layers: 1) the most significant bits (MSBs) layer and 2) the least significant bits (LSBs) layer. The MSBs layer provides rough depth value distribution, while the LSBs layer records the details of the depth value variation. For the MSBs layer, an error-controllable pixel domain encoding scheme is proposed to exploit the data correlation of the general depth information with sharp edges and to guarantee the data format of LSBs layer is 8 b after taking the quantization error from MSBs layer. For the LSBs layer, standard 8-b image/video codec is leveraged to perform the compression. The experimental results demonstrate that the proposed coding scheme can achieve real-time depth compression with satisfactory reconstruction quality. Moreover, the compressed depth data generated from this scheme can achieve better performance in view synthesis and gesture recognition applications compared with the conventional coding schemes because of the error control algorithm.

  11. Probing Small Lakes on Titan Using the Cassini RADAR Altimeter

    Science.gov (United States)

    Mastrogiuseppe, M.; Poggiali, V.; Hayes, A.; Lunine, J. I.; Seu, R.; Lorenz, R. D.; Mitri, G.; Mitchell, K. L.; Janssen, M. A.; Casarano, D.; Notarnicola, C.; Le Gall, A. A.

    2017-12-01

    The T126 Cassini's final flyby of Titan has offered a unique opportunity to observe an area in the Northern Polar terrain, where several small - medium size (10 - 50 km) hydrocarbon lakes are present and have been previously imaged by Cassini. The successful observation allowed the radar to operate at the closest approach over several small lakes, using its altimetry mode for the investigation of depth and liquid composition. Herein we present the result of a dedicate processing previously applied to altimetric data acquired over Ligeia Mare where the radar revealed the bathymetry and composition of the sea [1,2]. We show that, the optimal geometry condition met during the T126 fly-by allowed the radar to probe Titan's lakes revealing that such small liquid bodies can exceed one-hundred meters of depth. [1] M. Mastrogiuseppe et al. (2014, Mar.). The bathymetry of a Titan Sea. Geophysical Research Letters. [Online]. 41 (5), pp. 1432-1437. Available: http://dx.doi.org/10.1002/2013GL058618 [2] M.Mastrogiuseppe et al. (2016, Oct). Radar Sounding Using the Cassini Altimeter: Waveform Modeling and Monte Carlo Approach for Data Inversion of Observations of Titan's Seas, IEEE Transactions On Geoscience And Remote Sensing, Vol. 54, No. 10, doi: 10.1109/TGRS.2016.2563426.

  12. Neutrons as a probe

    International Nuclear Information System (INIS)

    Iizumi, Masashi

    1993-01-01

    As an introduction to the symposium a brief overview will be given about the features of neutrons as a probe. First it will be pointed out that the utilization of neutrons as a probe for investigating the structural and dynamical properties of condensed matters is a benign gift eventuated from the release of atomic energy initiated by Enrico Fermi exactly half century ago. Features of neutrons as a probe are discussed in accordance with the four basic physical properties of neutrons as an elementary particle; (1) no electric charge (the interaction with matter is nuclear), (2) the mass of neutron is 1 amu, (3) spin is 1/2 and (4) neutrons have magnetic dipole moment. Overview will be given on the uniqueness of neutrons as a probe and on the variety in the way they are used in the wide research area from the pure science to the industrial applications. (author)

  13. Depth Profiling Analysis of Aluminum Oxidation During Film Deposition in a Conventional High Vacuum System

    Science.gov (United States)

    Kim, Jongmin; Weimer, Jeffrey J.; Zukic, Muamer; Torr, Douglas G.

    1994-01-01

    The oxidation of aluminum thin films deposited in a conventional high vacuum chamber has been investigated using x-ray photoelectron spectroscopy (XPS) and depth profiling. The state of the Al layer was preserved by coating it with a protective MgF2 layer in the deposition chamber. Oxygen concentrations in the film layers were determined as a function of sputter time (depth into the film). The results show that an oxidized layer is formed at the start of Al deposition and that a less extensively oxidized Al layer is deposited if the deposition rate is fast. The top surface of the Al layer oxidizes very quickly. This top oxidized layer may be thicker than has been previously reported by optical methods. Maximum oxygen concentrations measured by XPS at each Al interface are related to pressure to rate ratios determined during the Al layer deposition.

  14. Is visual short-term memory depthful?

    Science.gov (United States)

    Reeves, Adam; Lei, Quan

    2014-03-01

    Does visual short-term memory (VSTM) depend on depth, as it might be if information was stored in more than one depth layer? Depth is critical in natural viewing and might be expected to affect retention, but whether this is so is currently unknown. Cued partial reports of letter arrays (Sperling, 1960) were measured up to 700 ms after display termination. Adding stereoscopic depth hardly affected VSTM capacity or decay inferred from total errors. The pattern of transposition errors (letters reported from an uncued row) was almost independent of depth and cue delay. We conclude that VSTM is effectively two-dimensional. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Probe tests microweld strength

    Science.gov (United States)

    1965-01-01

    Probe is developed to test strength of soldered, brazed or microwelded joints. It consists of a spring which may be adjusted to the desired test pressure by means of a threaded probe head, and an indicator lamp. Device may be used for electronic equipment testing.

  16. Non-inductive current probe

    DEFF Research Database (Denmark)

    Bak, Christen Kjeldahl

    1977-01-01

    The current probe described is a low-cost, shunt resistor for monitoring current pulses in e.g., pulsed lasers. Rise time is......The current probe described is a low-cost, shunt resistor for monitoring current pulses in e.g., pulsed lasers. Rise time is...

  17. Vegetation root zone storage and rooting depth, derived from local calibration of a global hydrological model

    Science.gov (United States)

    van der Ent, R.; Van Beek, R.; Sutanudjaja, E.; Wang-Erlandsson, L.; Hessels, T.; Bastiaanssen, W.; Bierkens, M. F.

    2017-12-01

    The storage and dynamics of water in the root zone control many important hydrological processes such as saturation excess overland flow, interflow, recharge, capillary rise, soil evaporation and transpiration. These processes are parameterized in hydrological models or land-surface schemes and the effect on runoff prediction can be large. Root zone parameters in global hydrological models are very uncertain as they cannot be measured directly at the scale on which these models operate. In this paper we calibrate the global hydrological model PCR-GLOBWB using a state-of-the-art ensemble of evaporation fields derived by solving the energy balance for satellite observations. We focus our calibration on the root zone parameters of PCR-GLOBWB and derive spatial patterns of maximum root zone storage. We find these patterns to correspond well with previous research. The parameterization of our model allows for the conversion of maximum root zone storage to root zone depth and we find that these correspond quite well to the point observations where available. We conclude that climate and soil type should be taken into account when regionalizing measured root depth for a certain vegetation type. We equally find that using evaporation rather than discharge better allows for local adjustment of root zone parameters within a basin and thus provides orthogonal data to diagnose and optimize hydrological models and land surface schemes.

  18. Maximum temperature accounts for annual soil CO2 efflux in temperate forests of Northern China

    Science.gov (United States)

    Zhou, Zhiyong; Xu, Meili; Kang, Fengfeng; Jianxin Sun, Osbert

    2015-01-01

    It will help understand the representation legality of soil temperature to explore the correlations of soil respiration with variant properties of soil temperature. Soil temperature at 10 cm depth was hourly logged through twelve months. Basing on the measured soil temperature, soil respiration at different temporal scales were calculated using empirical functions for temperate forests. On monthly scale, soil respiration significantly correlated with maximum, minimum, mean and accumulated effective soil temperatures. Annual soil respiration varied from 409 g C m−2 in coniferous forest to 570 g C m−2 in mixed forest and to 692 g C m−2 in broadleaved forest, and was markedly explained by mean soil temperatures of the warmest day, July and summer, separately. These three soil temperatures reflected the maximum values on diurnal, monthly and annual scales. In accordance with their higher temperatures, summer soil respiration accounted for 51% of annual soil respiration across forest types, and broadleaved forest also had higher soil organic carbon content (SOC) and soil microbial biomass carbon content (SMBC), but a lower contribution of SMBC to SOC. This added proof to the findings that maximum soil temperature may accelerate the transformation of SOC to CO2-C via stimulating activities of soil microorganisms. PMID:26179467

  19. NASA SMART Probe: Breast Cancer Application

    Science.gov (United States)

    Mah, Robert W.; Norvig, Peter (Technical Monitor)

    2000-01-01

    There is evidence in breast cancer and other malignancies that the physiologic environment within a tumor correlates with clinical outcome. We are developing a unique percutaneous Smart Probe to be used at the time of needle biopsy of the breast. The Smart Probe will simultaneously measure multiple physiologic parameters within a breast tumor. Direct and indirect measurements of tissue oxygen levels, blood flow, pH, and tissue fluid pressure will be analyzed in real-time. These parameters will be interpreted individually and collectively by innovative neural network techniques using advanced intelligent software. The goals are 1) develop a pecutaneous Smart Probe with multiple sensor modalities and applying advanced Information Technologies to provide real time diagnostic information of the tissue at tip of the probe, 2) test the percutaneous Smart Probe in women with benign and malignant breast masses who will be undergoing surgical biopsy, 3) correlate probe sensor data with benign and malignant status of breast masses, 4) determine whether the probe can detect physiologic differences within a breast tumor, and its margins, and in adjacent normal breast tissue, 5) correlate probe sensor data with known prognostic factors for breast caner, including tumor size, tumor grade, axillary lymph node metastases, estrogen receptor and progesterone receptor status.

  20. Probing the recreational home –The cultural probe as a communicative tool for researcher and user

    OpenAIRE

    Kristav, Per

    2005-01-01

    How can qualitative, ethnographic and emotional aspects from probe users be mapped at the same time as they get something meaningful in return? The emphasis is here on intellectual rewards during probe work rather than future good designs that in a long term perspective can be beneficial for the probe user. This case study has elaborated the traditional use of cultural probes [1] with a selection of ten families with small children in the Öresund region. The idea was to evoke thoughts abou...