Comparing maximum intercuspal contacts of virtual dental patients and mounted dental casts.
Delong, Ralph; Ko, Ching-Chang; Anderson, Gary C; Hodges, James S; Douglas, W H
2002-12-01
Quantitative measures of occlusal contacts are of paramount importance in the study of chewing dysfunction. A tool is needed to identify and quantify occlusal parameters without occlusal interference caused by the technique of analysis. This laboratory simulation study compared occlusal contacts constructed from 3-dimensional images of dental casts and interocclusal records with contacts found by use of conventional methods. Dental casts of 10 completely dentate adults were mounted in a semi-adjustable Denar articulator. Maximum intercuspal contacts were marked on the casts using red film. Intercuspal records made with an experimental vinyl polysiloxane impression material recorded maximum intercuspation. Three-dimensional virtual models of the casts and interocclusal records were made using custom software and an optical scanner. Contacts were calculated between virtual casts aligned manually (CM), aligned with interocclusal records scanned seated on the mandibular casts (C1) or scanned independently (C2), and directly from virtual interocclusal records (IR). Sensitivity and specificity calculations used the marked contacts as the standard. Contact parameters were compared between method pairs. Statistical comparisons used analysis of variance and the Tukey-Kramer post hoc test (P= CM/C1 = CM/C2 > C2/IR > CM/IR > C1/IR, where ">" means "closer than." Within the limits of this study, occlusal contacts calculated from aligned virtual casts accurately reproduce articulator contacts.
Directory of Open Access Journals (Sweden)
Marcelo Matida Hamata
2009-02-01
Full Text Available Fabrication of occlusal splints in centric relation for temporomandibular disorders (TMD patients is arguable, since this position has been defined for asymptomatic stomatognathic system. Thus, maximum intercuspation might be employed in patients with occlusal stability, eliminating the need for interocclusal records. This study compared occlusal splints fabricated in centric relation and maximum intercuspation in muscle pain reduction of TMD patients. Twenty patients with TMD of myogenous origin and bruxism were divided into 2 groups treated with splints in maximum intercuspation (I or centric relation (II. Clinical, electrognathographic and electromyographic examinations were performed before and 3 months after therapy. Data were analyzed by the Student's t test. Differences at 5% level of probability were considered statistically significant. There was a remarkable reduction in pain symptomatology, without statistically significant differences (p>0.05 between the groups. There was mandibular repositioning during therapy, as demonstrated by the change in occlusal contacts on the splints. Electrognathographic examination demonstrated a significant increase in maximum left lateral movement for group I and right lateral movement for group II (p0.05 in the electromyographic activities at rest after utilization of both splints. In conclusion, both occlusal splints were effective for pain control and presented similar action. The results suggest that maximum intercuspation may be used for fabrication of occlusal splints in patients with occlusal stability without large discrepancies between centric relation and maximum intercuspation. Moreover, this technique is simpler and less expensive.
Hamata, Marcelo Matida; Zuim, Paulo Renato Junqueira; Garcia, Alicio Rosalino
2009-01-01
Fabrication of occlusal splints in centric relation for temporomandibular disorders (TMD) patients is arguable, since this position has been defined for asymptomatic stomatognathic system. Thus, maximum intercuspation might be employed in patients with occlusal stability, eliminating the need for interocclusal records. This study compared occlusal splints fabricated in centric relation and maximum intercuspation in muscle pain reduction of TMD patients. Twenty patients with TMD of myogenous origin and bruxism were divided into 2 groups treated with splints in maximum intercuspation (I) or centric relation (II). Clinical, electrognathographic and electromyographic examinations were performed before and 3 months after therapy. Data were analyzed by the Student's t test. Differences at 5% level of probability were considered statistically significant. There was a remarkable reduction in pain symptomatology, without statistically significant differences (p>0.05) between the groups. There was mandibular repositioning during therapy, as demonstrated by the change in occlusal contacts on the splints. Electrognathographic examination demonstrated a significant increase in maximum left lateral movement for group I and right lateral movement for group II (p0.05) in the electromyographic activities at rest after utilization of both splints. In conclusion, both occlusal splints were effective for pain control and presented similar action. The results suggest that maximum intercuspation may be used for fabrication of occlusal splints in patients with occlusal stability without large discrepancies between centric relation and maximum intercuspation. Moreover, this technique is simpler and less expensive.
Hamata,Marcelo Matida; Zuim,Paulo Renato Junqueira; Garcia,Alicio Rosalino
2009-01-01
Fabrication of occlusal splints in centric relation for temporomandibular disorders (TMD) patients is arguable, since this position has been defined for asymptomatic stomatognathic system. Thus, maximum intercuspation might be employed in patients with occlusal stability, eliminating the need for interocclusal records. This study compared occlusal splints fabricated in centric relation and maximum intercuspation in muscle pain reduction of TMD patients. Twenty patients with TMD of myogenous o...
The effect of impression volume and double-arch trays on the registration of maximum intercuspation.
Hahn, Sara M; Millstein, Philip L; Kinnunen, Taru H; Wright, Robert F
2009-12-01
The type of double-arch trays used may affect occlusion. The purpose of this study was to determine what effect, if any, double-arch tray design and impression material volume had on the registration of maximum intercuspation (MI). Quadrant impressions were made on articulated fracture-resistant dental casts mounted in maximum intercuspation occlusion. Three types of sideless double-arch impression trays were used: First Bite with nylon webbing, Sultan's 3-Way with double crosshatch webbing, and Premium's 3-in-1 Tray with single crosshatch webbing. Vinyl polysiloxane impression material (Aquasil Ultra Rigid Fast Set) was distributed at 2 different volumes (5.4 ml and 8.3 ml), and 60 impressions were made (n=10). A weight of 1.2 kg was placed on the upper arm of an Artex articulator, ensuring complete closure. The impressions were allowed to polymerize for 5 minutes. After polymerization, specimens were placed on a light box, and a camera set at a fixed distance was used to capture the light transmission that was projected through the impression material. The camera transferred the information to an image analysis program (ImageJ). This system allowed the different amounts of light projected through the impression to be translated into a gray scale value (GSV), which was assigned a thickness value, in millimeters, of a specified occlusal contact area. To assess reliability of the experimental design, 10 control impressions were made by directly applying impression material onto the typodont. These were analyzed in the same manner as the impressions made with trays. A 2-way ANOVA comparing volume by tray type was used (alpha=.05). This was followed by a Tukey HSD test. There was no main effect for volume of impression material (P=.71). Tray type was significantly different (Precord making.
Wang, X-R; Zhang, Y; Xing, N; Xu, Y-F; Wang, M-Q
2013-05-01
Data are inconsistent concerning whether the level of the surface electromyographic (SEMG) activity of jaw-closing muscles increases when biting forces elevated during maximal voluntary clenching (MVC). In this study, T-Scan III system and BioEMG III system were used to record bite force, occlusal contacts and SEMG activity of the anterior temporalis (TA) and of the masseter muscles (MM) simultaneously. Recordings were obtained from 16 healthy young adult males during different conditions: (i) a fast MVC from resting position to intercuspal position (ICP); (ii) mandibular movements from ICP to protrusive or lateral edge-to-edge positions with teeth in contact with biting; (iii) a fast MVC in protrusive and lateral edge-to-edge positions. A higher level of SEMG activity was associated with a higher bite force during occluding movements (P < 0.05). However, during fast MVC from rest to ICP, the largest number of occlusal contacts was achieved and distributed more symmetrically, the highest level of biting force was obtained, but the SEMG activity of the jaw elevator muscles was reduced compared with its maximum level (P < 0.05). This phenomenon was not observed during the fast MVC in protrusive or lateral edge-to-edge positions. The present results that a lower SEMG activity was associated with the largest number of occlusal contacts and the highest level of bite force during centric MVC demonstrated a complex integration of jaw-closing muscles when a stable occlusion is present. © 2013 Blackwell Publishing Ltd.
Sheikholeslam, A; Riise, C
1983-05-01
The effects of an intercuspal occlusal interference on the pattern of activity of the anterior temporal and masseter muscles during submaximal and maximal bite, were studied in eleven volunteers with complete, natural dentitions. The results show that, during maximal and submaximal bite an occlusal interference (about 0.5 mm) in the intercuspal position is able to disturb the almost symmetric pattern of muscular activity in the anterior temporal and masseter muscles. Further, the level of muscular activity during maximal bite decreased significantly in all muscles studied. In some subjects, the decrease of muscular activity could still be observed one week after insertion of the interfering contact. After eliminating the interference, the muscular co-ordination pattern improved and the level of muscular activity increased significantly.
Effect of occlusal contact stability on the jaw closing point during tapping movements.
Nishigawa, Keisuke; Suzuki, Yoshitake; Ishikawa, Teruaki; Bando, Eiichi
2012-04-01
We studied the relationship between tapping point reproducibility and stability of occlusal contacts at maximum intercuspation. Tapping movements of 12 adult volunteers who had dentition with natural teeth were recorded, and distances between the tapping point (TP) and the intercuspal position (ICP) at the incisal point were calculated. Occlusal contacts at the ICP of individual subjects were also evaluated with black-colored silicone impression material. The correlation between TP-ICP distance and occlusal contact stability was studied. TP-ICP distance exhibited negative correlations with the total number of teeth showing occlusal contact at the ICP. Standard deviations of TP-ICP distance also negatively correlated with the extension of occlusal contact area over dentition. This finding indicates that occlusal contacts at the ICP affect the kinematic behavior of tapping movements. The results of this study also suggest that jaw movement data may provide useful clinical information for the evaluation of occlusal contact at ICP. Copyright © 2011 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Ferrario, V F; Sforza, C; Serrao, G; Colombo, A; Schmitz, J H
1999-07-01
In 13 healthy subjects (eight men and five women, mean age, 22 years), an aluminum intercuspal interference (height, 0.25 mm) was placed on the maxillary right first premolar to study its effect on the contractile symmetry of the right and left masseter and anterior temporalis muscles when measured through a Percentage Overlapping Coefficient (POC), derived from surface electromyographic recordings of maximum voluntary teeth clenching. Additionally, and to estimate the potential of the experimental intercuspal interference to induce lateral displacement of the mandible, a Torque Coefficient (TC) was derived from surface electromyographic recordings. The conclusion was that the experimental occlusal interference gave rise to asymmetric contractile activity in the studied mandibular elevator muscles as well as a potential to displace the mandible in a lateral direction.
Accuracy of Buccal Scan Procedures for the Registration of Habitual Intercuspation.
Zimmermann, M; Ender, A; Attin, T; Mehl, A
2018-04-09
Accurate reproduction of the jaw relationship is important in many fields of dentistry. Maximum intercuspation can be registered with digital buccal scan procedures implemented in the workflow of many intraoral scanning systems. The aim of this study was to investigate the accuracy of buccal scan procedures with intraoral scanning devices for the registration of habitual intercuspation in vivo. The hypothesis was that there is no statistically significant difference for buccal scan procedures compared to registration methods with poured model casts. Ten individuals (full dentition, no dental rehabilitations) were subjects for five different habitual intercuspation registration methods: (CI) poured model casts, manual hand registration, buccal scan with inEOS X5; (BC) intraoral scan, buccal scan with CEREC Bluecam; (OC4.2) intraoral scan, buccal scan with CEREC Omnicam software version 4.2; (OC4.5β) intraoral scan, buccal scan with CEREC Omnicam version 4.5β; and (TR) intraoral scan, buccal scan with Trios 3. Buccal scan was repeated three times. Analysis of rotation (Rot) and translation (Trans) parameters was performed with difference analysis software (OraCheck). Statistical analysis was performed with one-way analysis of variance and the post hoc Scheffé test ( p0.05) differences in terms of translation between groups CI_Trans (98.74±112.01 μm), BC_Trans (84.12±64.95 μm), OC4.2_Trans (60.70±35.08 μm), OC4.5β_Trans (68.36±36.67 μm), and TR_Trans (66.60±64.39 μm). For rotation, there were no significant differences ( p>0.05) for groups CI_Rot (0.23±0.25°), BC_Rot (0.73±0.52°), OC4.2_Rot (0.45±0.31°), OC4.5β_Rot (0.50±0.36°), and TR_Rot (0.47±0.65°). Intraoral scanning devices allow the reproduction of the static relationship of the maxillary and mandibular teeth with the same accuracy as registration methods with poured model casts.
Hu, Z W; Li, W W; Zhang, X Y; Fan, B L; Wang, Y; Sun, Y C
2016-08-01
To develop a aided mechanical appliance for rapid reconstruction of three-dimensional(3D)relationship of dentition model after scanning and evaluation of its accuracy. The appliance was designed by forward engineering software and fabricated by a high precision computer numerical control(CNC)system. It contained upper and lower body, magnetic pedestal and three pillars. Nine 3 mm diameter hemispheres were distributed equally on the axial surface of each pedestal. Faro Edge 1.8m was used to directly obtain center of each hemisphere(contact method), defined as known center. A pair of die-stone standard dentition model were fixed in intercuspal position and then fixed on the magnetic pedestals with low expansion ratio plaster. Activity 880 dental scanner was used to scan casts after the plaster was completely set. In Geomagic 2012, the centers of each hemisphere were fitted and defined as scanning centers. Scanning centers were aligned to known centers by reference point system to finish the 3D reconstruction of the intercuspal occlusion for the dentition casts. An observation coordinate system was interactively established. The straight-line distances in the X(coronal), Y(saggital), and Z(vertical)between the remaining 6 pairs of center points derived from contact method and fitting method were measured respectively and analyzed using a paired t-test. The differences of the straight-line distances of the remaining 6 pairs of center points between the two methods were X:(-0.05±0.10)mm, Y:(0.02±0.06)mm, and Z:(0.01 ± 0.05)mm. The results of paired t-test showed no significant differences(P>0.05). The mechanical appliance can help to reconstruct 3D jaw relation by scanning single upper and lower dentition model with usual commercial available dental cast scanning system.
Optimal design of the gerotor (2-ellipses) for reducing maximum contact stress
Energy Technology Data Exchange (ETDEWEB)
Kwak, Hyo Seo; Li, Sheng Huan [Dept. of Mechanical Convergence Technology, Pusan National University, Busan (Korea, Republic of); Kim, Chul [School of Mechanical Design and Manufacturing, Busan Institute of Science and Technology, Busan (Korea, Republic of)
2016-12-15
The oil pump, which is used as lubricator of engines and auto transmission, supplies working oil to the rotating elements to prevent wear. The gerotor pump is used widely in the automobile industry. When wear occurs due to contact between an inner rotor and an outer rotor, the efficiency of the gerotor pump decreases rapidly, and elastic deformation from the contacts also causes vibration and noise. This paper reports the optimal design of a gerotor with a 2-ellipses combined lobe shape that reduces the maximum contact stress. An automatic program was developed to calculate Hertzian contact stress of the gerotor using the Matlab and the effect of the design parameter on the maximum contact stress was analyzed. In addition, the method of theoretical analysis for obtaining the contact stress was verified by performing the fluid-structural coupled analysis using the commercial software, Ansys, considering both the driving force of the inner rotor and the fluid pressure, which is generated by working oil.
Fatigue life prediction method for contact wire using maximum local stress
Energy Technology Data Exchange (ETDEWEB)
Kim, Yong Seok; Haochuang, Li; Seok, Chang Sung; Koo, Jae Mean [Sungkyunkwan University, Suwon (Korea, Republic of); Lee, Ki Won; Kwon, Sam Young; Cho, Yong Hyeon [Korea Railroad Research Institute, Uiwang (Korea, Republic of)
2015-01-15
Railway contact wires supplying electricity to trains are exposed to repeated mechanical strain and stress caused by their own weight and discontinuous contact with a pantograph during train operation. Since the speed of railway transportation has increased continuously, railway industries have recently reported a number of contact wire failures caused by mechanical fatigue fractures instead of normal wear, which has been a more common failure mechanism. To secure the safety and durability of contact wires in environments with increased train speeds, a bending fatigue test on contact wire has been performed. The test equipment is too complicated to evaluate the fatigue characteristics of contact wire. Thus, the axial tension fatigue test was performed for a standard specimen, and the bending fatigue life for the contact wire structure was then predicted using the maximum local stress occurring at the top of the contact wire. Lastly, the tested bending fatigue life of the structure was compared with the fatigue life predicted by the axial tension fatigue test for verification.
Fatigue life prediction method for contact wire using maximum local stress
International Nuclear Information System (INIS)
Kim, Yong Seok; Haochuang, Li; Seok, Chang Sung; Koo, Jae Mean; Lee, Ki Won; Kwon, Sam Young; Cho, Yong Hyeon
2015-01-01
Railway contact wires supplying electricity to trains are exposed to repeated mechanical strain and stress caused by their own weight and discontinuous contact with a pantograph during train operation. Since the speed of railway transportation has increased continuously, railway industries have recently reported a number of contact wire failures caused by mechanical fatigue fractures instead of normal wear, which has been a more common failure mechanism. To secure the safety and durability of contact wires in environments with increased train speeds, a bending fatigue test on contact wire has been performed. The test equipment is too complicated to evaluate the fatigue characteristics of contact wire. Thus, the axial tension fatigue test was performed for a standard specimen, and the bending fatigue life for the contact wire structure was then predicted using the maximum local stress occurring at the top of the contact wire. Lastly, the tested bending fatigue life of the structure was compared with the fatigue life predicted by the axial tension fatigue test for verification.
Abduo, Jaafar
2017-01-01
This study evaluated and compared the effect of conventional and digital wax-ups on three lateral occlusion variables: contact number, contact area, and steepness. Dental casts of 10 patients with Angle Class I relationship were included in the study. All patients required fixed prosthodontic treatment that would affect lateral occlusion. The casts of all patients received conventional and digital wax-ups. For pretreatment, conventional wax-up, and digital wax-up casts, contact number, contact area, and occlusion steepness were measured at four lateral positions, that is, at excursions of 0.5, 1.0, 2.0, and 3.0 mm from maximal intercuspation. Lateral occlusion scheme variables were affected by use of diagnostic wax-ups. For all types of casts, contact number decreased as excursion increased. The two types of wax-ups had similar contact number patterns, and contact number was significantly greater for these casts than for pretreatment casts in the earlier stages of excursion. Similarly, contact area gradually decreased with increasing excursion in the pretreatment and conventional and digital wax-up casts. There was only a minimal decrease in occlusion steepness as excursion increased. However, lateral occlusion was generally steeper for digital wax-up casts.
Choi, Y J; Lim, H; Chung, C J; Park, K H; Kim, K H
2014-06-01
This study was performed to examine the longitudinal changes in bite force and occlusal contact area after mandibular setback surgery via intraoral vertical ramus osteotomy (IVRO). Patients with mandibular prognathism who underwent IVRO (surgical group: 39 men and 39 women) were compared with subjects with class I skeletal and dental relationships (control group; 32 men and 35 women). The surgical group was divided into two subgroups: 1-jaw surgery (n = 30) and 2-jaw surgery (n = 48). Bite force and contact area were measured in maximum intercuspation with the Dental Prescale System before treatment, within 1 month before surgery, and at 1, 3, 6, 9, 12, and 24 months postsurgery. A linear mixed model was used to investigate the time-dependent changes and associated factors. Bite force and contact area decreased during presurgical orthodontic treatment, were minimal at 1 month postsurgery, and increased gradually thereafter. The 1-jaw and 2-jaw subgroups showed no significant differences in bite force. The time-dependent changes in bite force were significantly different according to the contact area (P contact area gradually increase throughout the postsurgical evaluation period. Increasing the occlusal contact area may be essential for improving bite force after surgery. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Christensen, L V; Rassouli, N M
1995-07-01
In 12 subjects, a rigid unilateral intercuspal interference (minimum mean height of 0.24 mm) was placed on either the right or left mandibular second premolar and first molar (sagittal physiological equilibrium point of the hemimandibular dental arch). During brisk and forceful clenching on the interference, bipolar surface electromyograms were obtained from the right and left masseter muscles. On the side opposite the interference, myoelectric clenching activity was significantly reduced. Correlation analyses showed that the interference elicited a non-linear (complex) co-ordination of the amplitude, but not the duration, of bilateral masseteric clenching activity, i.e. frequently there was significant motor facilitation on the side of the interference, and significant motor inhibition on the side opposite the interference. Theoretical considerations predicted that brief clenching on the interference would easily lead to frontal plane rotatory motions of the mandible which, indeed, occurred clinically.
Fracture analysis of randomized implant-supported fixed dental prostheses
Esquivel-Upshaw, Josephine F.; Mehler, Alex; Clark, Arthur E.; Neal, Dan; Anusavice, Kenneth J.
2014-01-01
Objective Fractures of posterior fixed dental all-ceramic prostheses can be caused by one or more factors including prosthesis design, flaw distribution, direction and magnitude of occlusal loading, and nature of supporting infrastructure (tooth root/implant), and presence of adjacent teeth. This clinical study of implant-supported, all-ceramic fixed dental prostheses, determined the effects of (1) presence of a tooth distal to the most distal retainer; (2) prosthesis loading either along the non-load bearing or load bearing areas; (3) presence of excursive contacts or maximum intercuspation contacts in the prosthesis; and (4) magnitude of bite force on the occurrence of veneer ceramic fracture. Methods 89 implant-supported FDPs were randomized as either a three-unit posterior metal-ceramic (Au-Pd-Ag alloy and InLine POM, Ivoclar, Vivadent) FDP or a ceramic-ceramic (ZirCAD and ZirPress, Ivoclar, Vivadent) FDP. Two implants (Osseospeed, Dentsply) and custom abutments (Atlantis, Dentsply) supported these FDPs, which were cemented with resin cement (RelyX Universal Cement). Baseline photographs were made with markings of teeth from maximum intercuspation (MI) and excursive function. Patients were recalled at 6 months and 1 to 3 years. Fractures were observed, their locations recorded, and images compared with baseline photographs of occlusal contacts. Conclusion No significant relationship exists between the occurrence of fracture and: (1) the magnitude of bite force; (2) a tooth distal to the most distal retainer; and (3) contacts in load-bearing or non-load-bearing areas. However, there was a significantly higher likelihood of fracture in areas with MI contacts only. Clinical Significance This clinical study demonstrates that there is a need to evaluate occlusion differently with implant-supported prostheses than with natural tooth supported prostheses because of the absence of a periodontal ligament. Implant supported prostheses should have minimal occlusion and
OCCLUSION AND ARTICULATION IN BRUXISM AND BRUXOMANIA INVESTIGATED WITH THE SYSTEM T-SCAN III.
Mariana Dimova
2014-01-01
Aim: To be analyzed common features of occlusal relationships in patients with bruxism and bruxomania at maximum intercuspation (MIP) and eccentric jaw movements. Materials and Methods: 30 patients (22 women and 8 men, mean aged of 42,8 ± 13,3) with bruxism and/or bruxomania are examined with the system T-Scan III. Sequence of records is - at maximum intercuspation (MIP); in manual leading to central relation and in eccentric jaw movements. In the same sequence is investigated control ...
OCCLUSION AND ARTICULATION IN BRUXISM AND BRUXOMANIA INVESTIGATED WITH THE SYSTEM T-SCAN III.
Directory of Open Access Journals (Sweden)
Mariana Dimova
2014-11-01
Full Text Available Aim: To be analyzed common features of occlusal relationships in patients with bruxism and bruxomania at maximum intercuspation (MIP and eccentric jaw movements. Materials and Methods: 30 patients (22 women and 8 men, mean aged of 42,8 ± 13,3 with bruxism and/or bruxomania are examined with the system T-Scan III. Sequence of records is - at maximum intercuspation (MIP; in manual leading to central relation and in eccentric jaw movements. In the same sequence is investigated control group - 30 people (15 women and 15 men aged between 21 and 45 who didn’t have bruxism and/or bruxomania and dentition is preserved. Results: In the control group 85% of cases there is a balance of forces in both halves of the dental arch. In patients with bruxism is established uneven distribution of forces in MIP and articulation blockages (95%. There are three major reasons that impede spontaneous bilateral closing - force outliers (93% of cases; low force outliers (82% and presence of interceptive contacts and sliding occurring in the beginning of occlusion time until MIP (in all patients. Conclusions: In order to achieve a balanced occlusion in patients with bruxism and/or bruxomania required are correct diagnosis, registration and removal of preliminary contacts, articulation blockages and infraocclusion. Occlusal analysis is objective and an indicator of subsequent treatment only when it is a combination of clinical, instrumental and computerized occlusal analysis.
Sixty-eight years of experimental occlusal interference studies: what have we learned?
Clark, G T; Tsukiyama, Y; Baba, K; Watanabe, T
1999-12-01
Understanding is needed regarding the effect that occlusal interferences have on the teeth, periodontium, and especially on jaw function. This article summarizes research in which experimental occlusal interferences have been placed on the teeth of animals and human volunteers. Data from 18 human and 10 animals studies were reviewed. Experimental occlusal interferences were grouped into those that alter intercuspal position and those contacting on lateral jaw movement only. The outcome of these interferences were analyzed according to their local pulpal-periodontal, jaw function, or bruxism effects. Experimental occlusal interferences in maximum intercuspation had a deleterious effect on periodontal and pulpal tissues of the affected tooth; sometimes this produces a disruption of smooth jaw function and occasionally jaw muscle pain and clicking. Experimental occlusal interferences that contact only in a lateral jaw movement are infrequently harmful to jaw function. Furthermore, no reliable evidence demonstrates that occlusal interferences can cause nocturnal bruxism, or stop it. Transient local tooth pain, loosening of the tooth, a slight change in postural muscle tension levels, chewing stroke patterns, and sometimes a clicking joint can be induced by an experimental occlusal interference. Because such findings are present in relatively asymptomatic patients, these data do not prove that occlusal interferences are causally related to a chronic jaw muscle pain or temporomandibular joint dysfunction problems.
Fuentes, Aler D; Martin, Conchita; Bull, Ricardo; Santander, Hugo; Gutiérrez, Mario F; Miralles, Rodolfo
2016-07-01
There is scarce knowledge regarding the influence of a natural mediotrusive contact on mandibular and cervical muscular activity. The purpose of this study was to analyze the EMG activity of the anterior temporalis (AT) and sternocleidomastoid (SCM) muscles during awake grinding in healthy subjects with or without a natural mediotrusive occlusal contact. Fifteen subjects with natural mediotrusive occlusal contact (Group 1) and 15 subjects without natural mediotrusive occlusal contact (Group 2) participated. Bilateral surface EMG activity of AT and SCM muscles was recorded during unilateral eccentric or concentric tooth grinding tasks. EMG activity was normalized against the activity recorded during maximal voluntary clenching in intercuspal position (IP) for AT muscles and during maximal intentional isometric head-neck rotation to each side, for SCM muscles. EMG activity of AT and SCM muscles showed no statistical difference between groups. EMG activity of AT muscle was higher in the working side (WS) than in the non-WS (NWS) in Group 1 during concentric grinding (0.492 vs 0.331, p = 0.047), whereas no difference was observed in Group 2. EMG activity of SCM was similar between working and NWSs in both groups and tasks. Asymmetry indexes (AIs) were not significantly different between groups. These findings in healthy subjects support the assumption that during awake tooth grinding, central nerve control predominates over peripheral inputs, and reinforce the idea of a functional link between the motor-neuron pools that control jaw and neck muscles.
Directory of Open Access Journals (Sweden)
Agus Risdiyanto
2012-12-01
Full Text Available This paper discussed the influence of tightness or contacts pressure on copper busbar joints to determine changes in the value of the initial contact resistance and the maximum temperature at the joint due to high current load. The test sample was copper busbar 3 x 30 mm with configuration of bolted overlapping joint. Increasing contact pressure at the joint was measured to find out its effect on the value of contact resistance. The applied pressure was 6 to 36 MPa. Procedure of contact resistance measurement refer to the ASTM B539 standard using four-wire method. The sample subsequently loaded with the current of 350 A for 60 minutes and the maximum temperature at the joint was measured. The result showed that increasing contact pressure at the busbar joint will reduce the contact resistance and maximum temperature. The increase of contact pressure from 6 to 30 MPa causes decreasing contact resistance from 16 μΩ to 11 μΩ. Further increasing of contact pressure more than 30 MPa did not affect the contact resistance significantly. The lowest temperatur of busbar joint of 54°C was reached at a contact pressure of 36 Mpa.
Riise, C; Sheikholeslam, A
1984-07-01
Quantitative electromyography (EMG) was used to study, in eleven volunteers with complete, natural dentitions, the effects of an experimental intercuspal occlusal interference on the pattern of activity of the anterior temporal and masseter muscles during mastication. The results show that a small occlusal interference (about 0.5 mm) in the intercuspal position can change the co-ordination of muscular activity during mastication. In general, there was a prolonged contraction time as well as a reduction of the activity in all the investigated elevators, especially on the side of the interference. Furthermore, after 48 h several subjects preferred to chew unilaterally. After removal of the interference, the pattern of co-ordination of muscular activity returned almost to the pre-experimental pattern within 2 weeks.
Ocular surface displacement with and without contact lenses during non-contact tonometry.
Rimayanti, Ulfah; Kiuchi, Yoshiaki; Uemura, Shohei; Takenaka, Joji; Mochizuki, Hideki; Kaneko, Makoto
2014-01-01
To evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP) reading changes caused by wearing soft contact lenses (CLs). One eye each in 21 subjects was studied. The cornea was photographed using a high-speed camera at 5,000 frames/sec during non-contact tonometry without contact lenses (NCL), with -5.0 diopters (D), -0.5 D and +5.0 D CL. The displacement of the ocular surface and the factors affecting displacement at the IOP reading and maximum displacement time were investigated. The IOP readings while wearing +5 D CL were significantly higher than those obtained while wearing -5 D CL. The ocular surface displacement between +5 D CL and other groups were significantly different. A significant positive correlation was found between the ocular surface displacement of subjects at the IOP reading time and the IOP obtained with the non-contact tonometer. A significant negative correlation was found between the ocular surface curvature and the IOP obtained using the non-contact tonometer. The radius of curvature of the ocular surface affected the displacement during the IOP reading and maximum displacement time. Our results indicate that soft contact lens use changes the ocular surface behavior and IOP readings during non-contact tonometry. The radius of curvature of the eye affects the ocular surface displacement and IOP readings in this situation.
Simulation Results: Optimization of Contact Ratio for Interdigitated Back-Contact Solar Cells
Directory of Open Access Journals (Sweden)
Vinay Budhraja
2017-01-01
Full Text Available In the fabrication of interdigitated back contact (IBC solar cells, it is very important to choose the right size of contact to achieve the maximum efficiency. Line contacts and point contacts are the two possibilities, which are being chosen for IBC structure. It is expected that the point contacts would give better results because of the reduced recombination rate. In this work, we are simulating the effect of contact size on the performance of IBC solar cells. Simulations were done in three dimension using Quokka, which numerically solves the charge carrier transport. Our simulation results show that around 10% of contact ratio is able to achieve optimum cell efficiency.
Ocular surface displacement with and without contact lenses during non-contact tonometry.
Directory of Open Access Journals (Sweden)
Ulfah Rimayanti
Full Text Available PURPOSE: To evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP reading changes caused by wearing soft contact lenses (CLs. METHODS: One eye each in 21 subjects was studied. The cornea was photographed using a high-speed camera at 5,000 frames/sec during non-contact tonometry without contact lenses (NCL, with -5.0 diopters (D, -0.5 D and +5.0 D CL. The displacement of the ocular surface and the factors affecting displacement at the IOP reading and maximum displacement time were investigated. RESULTS: The IOP readings while wearing +5 D CL were significantly higher than those obtained while wearing -5 D CL. The ocular surface displacement between +5 D CL and other groups were significantly different. A significant positive correlation was found between the ocular surface displacement of subjects at the IOP reading time and the IOP obtained with the non-contact tonometer. A significant negative correlation was found between the ocular surface curvature and the IOP obtained using the non-contact tonometer. The radius of curvature of the ocular surface affected the displacement during the IOP reading and maximum displacement time. CONCLUSIONS: Our results indicate that soft contact lens use changes the ocular surface behavior and IOP readings during non-contact tonometry. The radius of curvature of the eye affects the ocular surface displacement and IOP readings in this situation.
Favot, Louis-Marc; Berry-Kromer, Valérie; Haboussi, Mohamed; Thiebaud, Frédéric; Ben Zineb, Tarak
2014-03-01
The study dealt with full dental prosthetic reconstruction on four implants. The aim was to analyse the influence of material parameters on the mechanical behaviour of the restored mandible compared to the natural mandible. A finite element model of an edentulous mandible with prosthetic rehabilitation was established. Four materials were investigated for the framework of the prosthesis (zirconia, titanium, gold and nickel-titanium (NiTi)), as well as three cortical bone thicknesses. Various muscles were employed to simulate the main stages of mastication. Three distinct phases of mastication were modelled: maximum intercuspation, incisal clench and unilateral molar clench. The zirconia framework demonstrated the highest stresses and NiTi the weakest. The highest stresses in the framework were obtained during maximum intercuspation. The highest stresses at the bone-implant interface were recorded on the working axial implant during unilateral molar clench and on tilted implants during maximum intercuspation. The influence of the framework's material stiffness on the stresses at the bone-implant interface was insignificant for axial implants (except the right implant during unilateral molar clench) and slightly more significant for tilted implants. Mandibular flexion decreased with an increase of the cortical bone thickness and the stiffness of the prosthetic framework's material. Among all materials, NiTi allowed a better preservation of the mandibular flexure, during all the mastication stages. Compared to stiffer materials, NiTi also permitted physiological mechanical conditions at the bone/implant interface, in almost all mastication stages. Copyright © 2013 Elsevier Ltd. All rights reserved.
Kingston, David C; Acker, Stacey M
2018-01-23
In high knee flexion, contact between the posterior thigh and calf is expected to decrease forces on tibiofemoral contact surfaces, therefore, thigh-calf contact needs to be thoroughly characterized to model its effect. This study measured knee angles and intersegmental contact parameters in fifty-eight young healthy participants for six common high flexion postures using motion tracking and a pressure sensor attached to the right thigh. Additionally, we introduced and assessed the reliability of a method for reducing noise in pressure sensor output. Five repetitions of two squatting, two kneeling, and two unilateral kneeling movements were completed. Interactions of posture by sex occurred for thigh-calf and heel-gluteal center of force, and thigh-calf contact area. Center of force in thigh-calf regions was farther from the knee joint center in females, compared to males, during unilateral kneeling (82 and 67 mm respectively) with an inverted relationship in the heel-gluteal region (331 and 345 mm respectively), although caution is advised when generalizing these findings from a young, relatively fit sample to a population level. Contact area was larger in females when compared to males (mean of 155.61 and 137.33 cm 2 across postures). A posture main effect was observed in contact force and sex main effects were present in onset and max angle. Males had earlier onset (121.0°) and lower max angle (147.4°) with onset and max angles having a range between movements of 8° and 3° respectively. There was a substantial total force difference of 139 N between the largest and smallest activity means. Force parameters measured in this study suggest that knee joint contact models need to incorporate activity-specific parameters when estimating loading. Copyright © 2017 Elsevier Ltd. All rights reserved.
Assessment of occlusion after placement of stainless steel crowns in children - a pilot study.
Gallagher, S; O'Connell, B C; O'Connell, A C
2014-10-01
Many stainless steel crowns (SSCs) disrupt the occlusion in children, but stabilisation appears to occur within a short period post-placement. The extent and mechanism of these short-term occlusal changes in children are unknown. This study sought to determine whether placement of a SSC changes the maximum intercuspation position (MIP) in children, whether the MIP returns to normal within 4 weeks and whether local anaesthesia had an effect on the child's ability to achieve MIP. The T-Scan(®) III was used for the measurement of occlusal contacts. Reliability and reproducibility of the system was determined using a calibration exercise where MIP recordings were taken of eleven children not undergoing any dental treatment. For the main study, the percentage of total occlusal force on each tooth was recorded in 20 children preoperatively, after local anaesthesia, after SSC placement and 4 weeks postoperatively. There was no significant difference in MIP (P = 0·435) preoperatively and post-administration of local anaesthesia. There was a significant difference between the preoperative force on a tooth and the reading after crown placement (P = 0·0013, Wilcoxon test). By 4 weeks, there was no significant difference overall between post-SSC placement and the preoperative value for the tooth (P = 0·3). Administration of local anaesthesia did not affect the ability of a child to attain MIP. Maximum intercuspation position was disturbed by the placement of a SSC in seven of 20 cases. When MIP was disturbed, in most cases, it returned to preoperative status within 4 weeks of crown placement. © 2014 John Wiley & Sons Ltd.
Optimal contact definition for reconstruction of Contact Maps
Directory of Open Access Journals (Sweden)
Stehr Henning
2010-05-01
contacts and structural alignments based on maximum contact map overlap.
Savrai, R. A.; Makarov, A. V.; Osintseva, A. L.; Malygina, I. Yu.
2018-02-01
Mechanical testing of the AISI 321 corrosion resistant austenitic steel for contact gigacycle fatigue has been conducted with the application of a new method of contact fatigue testing with ultrasonic frequency of loading according to a pulsing impact "plane-to-plane" contact scheme. It has been found that the contact endurance (the ability to resist the fatigue spalling) of the AISI 321 steel under contact gigacycle fatigue loading is determined by its plasticity margin and the possibility of additional hardening under contact loading. It is demonstrated that the appearance of localized deep and long areas of spalling on a material surface can serve as a qualitative characteristic for the loss of the fatigue strength of the AISI 321 steel under impact contact fatigue loading. The value of surface microhardness measured within contact spots and the maximum depth of contact damages in the peripheral zone of contact spots can serve as quantitative criteria for that purpose.
Maximum speed of dewetting on a fiber
Chan, Tak Shing; Gueudre, Thomas; Snoeijer, Jacobus Hendrikus
2011-01-01
A solid object can be coated by a nonwetting liquid since a receding contact line cannot exceed a critical speed. We theoretically investigate this forced wetting transition for axisymmetric menisci on fibers of varying radii. First, we use a matched asymptotic expansion and derive the maximum speed
Effects of bruxism on the maximum bite force
Directory of Open Access Journals (Sweden)
Todić Jelena T.
2017-01-01
Full Text Available Background/Aim. Bruxism is a parafunctional activity of the masticatory system, which is characterized by clenching or grinding of teeth. The purpose of this study was to determine whether the presence of bruxism has impact on maximum bite force, with particular reference to the potential impact of gender on bite force values. Methods. This study included two groups of subjects: without and with bruxism. The presence of bruxism in the subjects was registered using a specific clinical questionnaire on bruxism and physical examination. The subjects from both groups were submitted to the procedure of measuring the maximum bite pressure and occlusal contact area using a single-sheet pressure-sensitive films (Fuji Prescale MS and HS Film. Maximal bite force was obtained by multiplying maximal bite pressure and occlusal contact area values. Results. The average values of maximal bite force were significantly higher in the subjects with bruxism compared to those without bruxism (p 0.01. Maximal bite force was significantly higher in the males compared to the females in all segments of the research. Conclusion. The presence of bruxism influences the increase in the maximum bite force as shown in this study. Gender is a significant determinant of bite force. Registration of maximum bite force can be used in diagnosing and analysing pathophysiological events during bruxism.
Ueki, Koichiro; Moroi, Akinori; Sotobori, Megumi; Ishihara, Yuri; Marukawa, Kohei; Iguchi, Ran; Kosaka, Akihiko; Ikawa, Hiroumi; Nakazawa, Ryuichi; Higuchi, Masatoshi
2014-10-01
The purpose of this study was to evaluate the relationship between lip closing force, occlusal contact area and occlusal force after orthognathic surgery in skeletal Class III patients. The subjects consisted of 54 patients (28 female and 26 male) diagnosed with mandibular prognathism who underwent sagittal split ramus osteotomy with and without Le Fort I osteotomy. Maximum and minimum lip closing forces, occlusal contact area and occlusal force were measured pre-operatively, 6 months and 1 year post-operative. Maximum and minimum lip closing forces, occlusal contact area and occlusal force increased with time after surgery, however a significant increase was not found in the occlusal contact area in women. In increased ratio (6 months/pre-operative and 1 year/pre-operative), the maximum lip closing force was significantly correlated with the occlusal contact area (P contact area and lip closing force, and an increase ratio in maximum lip closing force was associated with an increased ratio in occlusal contact area. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Directory of Open Access Journals (Sweden)
Mariana Dimova
2014-06-01
Full Text Available The study and documentation of occlusal-articulation relationships has a high diagnostic significance in patients with bruxism and bruxomania. The study aims on the basis of registration of occlusal contacts via articulating paper and the T-Scan system to evaluate the advantages and disadvantages of both methods in occlusal diagnosis of patients with bruxism and bruxomania. Material and Methods: 40 patients with bruxism and / or bruxomania (29 women and 11 men aged between 21 and 77 years from October 2010 to February 2014 was conducted computerized occlusal analysis using the systems T-Scan II (in 12 patients, T-Scan III (in 28 patients and the software T-Scan III. All patients were subjected to registration of occlusal relationships in centric occlusion (CO with articulating paper Bausch PROGRESS 100 µ and Bausch® Arti-Fol® 8 µ. Results and Discussion: In 90.0% of patients it is established unevenly distributed, irregular in size and intensity occlusal contacts. Essential factor for preventing the spontaneous bilateral closure with balanced forces is the presence of interceptive contacts and sliding occurring in the first frame of the occlusion time until the maximum intercuspation - MIP. Conclusion: Registration with articulating paper visualizes cumulative picture of the contacts in CO and interceptive contacts without being able to distinguish them in size and time of onset. Computerized occlusal analysis objectively and quantitatively determines interceptive contacts and distinguishes them from contacts in MIP and gives real meaning to the terms "strong" and "light contacts".
Assessment of wheel propeller contact pressure upon soil with use of tire universal performance
Directory of Open Access Journals (Sweden)
Z. A. Godzhaev
2016-01-01
Full Text Available A maximum contact pressure is a key parameter characterizing a level of ecological impact of tractor propellers on the soil. The maximum pressure upon the soil varies with internal pressure in tires and vertical load of a wheel. An universal tire performance can be used at an assessment of change of contact pressure of a wheel propeller upon the soil. The authors offered a technique of definition and regulation of the maximum contact pressure of the wheel propeller upon the basic basis. This technique allows to set parameters for monitoring systems and regulation of the maximum pressure upon the soil by measurement of a tire deflection and change of pressure in tires. At statistical tests for determination of the maximum contact pressure it is necessary to consider the universal performance of the tire nomographically. This nomogram allows to consider visually influence of loading and internal pressure in the tire on a size of the maximum contact pressure. An internal pressure decrease in the tire makes it possible to reduce the maximum pressure upon the soil at constant loading. The authors investigated universal performances of the tires in the range of change of internal air pressure from 160 to 90 kPas. Change of internal pressure from 150 to 100 kPas reduce for the tire 15,5R38 the maximum contact pressure upon 13 kPas (9,6 percent: from 135 to 122 kPas. That corresponds to the admissible level of pressure upon the soil at its humidity in a layer of 0-30 cm: 0,5-0,6 minimum moisture-holding capacity during the spring period and 0,6-0,7 minimum moisture-holding capacity during the autumn period. In case of use of the tire 16,9R38 the maximum pressure upon the soil decreases from 84 to 75 kPas, that is by 10,4 percent.
Langohr, G Daniel G; Willing, Ryan; Medley, John B; Athwal, George S; Johnson, James A
2016-04-01
Implant design parameters can be changed during reverse shoulder arthroplasty (RSA) to improve range of motion and stability; however, little is known regarding their impact on articular contact mechanics. The purpose of this finite element study was to investigate RSA contact mechanics during abduction for different neck-shaft angles, glenosphere sizes, and polyethylene cup depths. Finite element RSA models with varying neck-shaft angles (155°, 145°, 135°), sizes (38 mm, 42 mm), and cup depths (deep, normal, shallow) were loaded with 400 N at physiological abduction angles. The contact area and maximum contact stress were computed. The contact patch and the location of maximum contact stress were typically located inferomedially in the polyethylene cup. On average for all abduction angles investigated, reducing the neck-shaft angle reduced the contact area by 29% for 155° to 145° and by 59% for 155° to 135° and increased maximum contact stress by 71% for 155° to 145° and by 286% for 155° to 135°. Increasing the glenosphere size increased the contact area by 12% but only decreased maximum contact stress by 2%. Decreasing the cup depth reduced the contact area by 40% and increased maximum contact stress by 81%, whereas increasing the depth produced the opposite effect (+52% and -36%, respectively). The location of the contact patch and maximum contact stress in this study matches the area of damage seen frequently on clinical retrievals. This finding suggests that damage to the inferior cup due to notching may be potentiated by contact stresses. Increasing the glenosphere diameter improved the joint contact area and did not affect maximum contact stress. However, although reducing the neck-shaft angle and cup depth can improve range of motion, our study shows that this also has some negative effects on RSA contact mechanics, particularly when combined. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc
Feng, Dong-Xia; Nguyen, Anh V
2017-10-01
The floatability of solid particles on the water surface governs many natural phenomena and industrial processes including film flotation and froth flotation separation of coal and valuable minerals. For many years, the contact angle (CA) has been postulated as the key factor in determining the particle floatability. Indeed, the maximum force (tenacity) supporting the flotation of fine spheres was conjectured to occur when the apical angle of the contact circle is equal to the contact angle. In this paper, the model predictions are reviewed and compared with experimental results. It is shown that CA can be affected by many physical and chemical factors such as surface roughness and chemical heterogeneity and can have a range of values known as the CA hysteresis. This multiple-valued CA invalidates the available theories on the floatability of spheres. Even the intuitive replacement of CA by the advancing (maximum) CA in the classical theories can be wrong. A few new examples are also reviewed and analyzed to demonstrate the significance of CA variation in controlling the particle floatability. They include the pinning of the contact line at the sharp edge, known as the Gibbs inequality condition, and the nearby interaction among floating particles, known as lateral inter-particle interaction. It is concluded that our quantitative understanding of the floatability of real particles being irregular and heterogeneous both morphologically and chemically is still far from being satisfactory. Copyright © 2017 Elsevier B.V. All rights reserved.
Relationship between oral status and maximum bite force in preschool children
Directory of Open Access Journals (Sweden)
Ching-Ming Su
2009-03-01
Conclusion: By combining the results of this study, it was concluded that associations of bite force with factors like age, maximum mouth opening and the number of teeth in contact were clearer than for other variables such as body height, body weight, occlusal pattern, and tooth decay or fillings.
Numerical simulations of rough contacts between viscoelastic materials
Spinu, S.; Cerlinca, D.
2017-08-01
The durability of the mechanical contact is often plagued by surface-related phenomena like rolling contact fatigue, wear or crack propagation, which are linked to the important gradients of stress arising in the contacting bodies due to interaction at the asperity level. The semi-analytical computational approach adopted in this paper is based on a previously reported algorithm capable of simulating the contact between bodies with arbitrary limiting surfaces and viscoelastic behaviour, which is enhanced and adapted for the contact of real surfaces with microtopography. As steep slopes at the asperity level inevitably lead to localized plastic deformation at the tip of the asperities that are first brought into contact, the viscoelastic behaviour is amended by limiting the maximum value of the pressure on the contact area to that of the material hardness, according to the Tabor equation. In this manner, plasticity is considered in a simplified manner that assures the knowledge of the contact area and of the pressure distribution without estimation of the residual state. The main advantage of this approach is the preservation of the algorithmic complexity, allowing the simulation of very fine meshes capable of capturing particular features of the investigated contacting surface. The newly advanced model is expected to predict the contact specifics of rough surfaces as resulting from various manufacturing processes, thus assisting the design of durable machine elements using elastomers or rubbers.
Contact mechanics: contact area and interfacial separation from small contact to full contact
International Nuclear Information System (INIS)
Yang, C; Persson, B N J
2008-01-01
We present a molecular dynamics study of the contact between a rigid solid with a randomly rough surface and an elastic block with a flat surface. The numerical calculations mainly focus on the contact area and the interfacial separation from small contact (low load) to full contact (high load). For a small load the contact area varies linearly with the load and the interfacial separation depends logarithmically on the load. For a high load the contact area approaches the nominal contact area (i.e. complete contact), and the interfacial separation approaches zero. The numerical results have been compared with analytical theory and experimental results. They are in good agreement with each other. The present findings may be very important for soft solids, e.g. rubber, or for very smooth surfaces, where complete contact can be reached at moderately high loads without plastic deformation of the solids
Dynamic Multi-Rigid-Body Systems with Concurrent Distributed Contacts: Theory and Examples
International Nuclear Information System (INIS)
TRINKLE, JEFFREY C.; TZITZOURIS, J.A.; PANG, J.S.
2001-01-01
Consider a system of rigid bodies with multiple concurrent contacts. The multi-rigid-body contact problem is to predict the accelerations of the bodies and the normal friction loads acting at the contacts. This paper presents theoretical results for the multi-rigid-body contact problem under the assumptions that one or more contacts occur over locally planar, finite regions and that friction forces are consistent with the maximum work inequality. Existence and uniqueness results are presented for this problem under mild assumptions on the system inputs. In addition, the performance of two different time-stepping methods for integrating the dynamics are compared on two simple multi-body systems
Shriram, Duraisamy; Parween, Rizuwana; Lee, Yee Han Dave; Subburaj, Karupppasamy
2017-07-01
Knee osteoarthritis that prevalently occurs at the medial compartment is a progressive chronic disorder affecting the articular cartilage of the knee joint, and lead to loss of joint functionality. Valgus braces have been used as a treatment procedure to unload the medial compartment for patients with medial osteoarthritis. Valgus braces through the application of counteracting external valgus moment shift the load from medial compartment towards the lateral compartment. Previous biomechanical studies focused only on the changes in varus moments before and after wearing the brace. The objective of this study was to investigate the influence of opposing external valgus moment applied by knee braces on the lateral tibial cartilage contact conditions using a 3D finite element model of the knee joint. Finite element simulations were performed on the knee joint model without and with the application of opposing valgus moment to mimic the unbraced and braced conditions. Lateral tibial cartilage contact pressures and contact area, and tibial rotation (varus-valgus and internal-external) were estimated for the complete walking gait cycle. The opposing valgus moment increased the maximum contact pressure and contact area on the lateral tibial cartilage compared to the normal gait moment. A peak contact pressure of 8.2 MPa and maximum cartilage loaded area of 28% (loaded cartilage nodes) on the lateral cartilage with the application of external valgus moment were induced at 50% of the gait cycle. The results show that the use of opposing valgus moment may significantly increase the maximum contact pressures and contact area on the lateral tibial cartilage and increases the risk of articular cartilage damage on the lateral compartment.
Behaviour of contact layer material between cermet fuel element core and can
International Nuclear Information System (INIS)
Gavrilin, S.S.; Permyakov, L.N.; Simakov, G.A.; Chernikov, A.S.
1996-01-01
The structural state of the contact layer between the shell of the Zr1Nb alloy and cermet fuel element core containing up to 70% of uranium dioxides is experimental studied. The silumin alloy was used as contact material. The results of studies on interaction zones, formed on the Zr1Nb - silumin boundary after fuel elements manufacture and also under temperature conditions, modeling the maximum design and hypothetical accidents accompanied by the contact material melting, are presented [ru
[Influences of balancing-side interference on jaw function].
Baba, K
1991-03-01
The influences of experimental balancing-side interference on the jaw function were investigated on 6 subjects. A specially designed onlay was fabricated for the lower second molar, which acted as an artificial balancing-side interference in the lateral mandibular position. The subjects were asked to do maximum clenching, lateral gliding and gum chewing with and without the device. Electromyographic activity of the masseter and the anterior and posterior temporal muscles were measured and the related mandibular movement was simultaneously recorded during these tasks. Introduction of the experimental interference caused alteration in the muscle activity as follows: 1. When the subjects exerted maximum clenching efforts in the lateral mandibular position, the ratio of the temporal muscle activity on the working-side to the balancing-side decreased, while that of the masseter muscle remained unchanged. 2. There was a tendency for the activity in the working-side posterior temporal muscle to increase during gliding from intercuspation. The ratio of the temporal muscle activity on the working-side to the balancing-side decreased during gliding into intercuspation. 3. Prolongation of the occlusal phase associated with the increase of the muscle activity was observed during gum chewing on the side opposite to the interference. It was suggested that the balancing-side interference might provoke a specific muscle activity in the temporal muscles during parafunctional clenching or grinding.
Methyldibromoglutaronitrile in rinse-off products causes allergic contact dermatitis
DEFF Research Database (Denmark)
Jensen, C D; Johansen, J D; Menné, T
2004-01-01
BACKGROUND: The frequency of sensitivity to the cosmetic preservative methyldibromoglutaronitrile (MDBGN) has increased significantly in Europe. Most cases of allergic contact dermatitis from MDBGN are caused by leave-on cosmetic products. The risk of developing allergic contact dermatitis from...... series of MDBGN to determine their patch test threshold values. RESULTS: Seven presensitized individuals (37%) developed allergic contact dermatitis from the soap containing MDBGN. The mean dose of MDBGN per application was 2.2 micro g cm-2 and the reactions appeared between days 6 and 34. All nine...... rinse-off products has been less studied. OBJECTIVES: To investigate the allergic response elicited in presensitized individuals from exposure to a rinse-off product preserved with the maximum permitted level of MDBGN. METHODS: Nineteen contact allergic individuals and nine controls participated...
Morimoto, Yusuke; Ferretti, Mario; Ekdahl, Max; Smolinski, Patrick; Fu, Freddie H
2009-01-01
The purpose of this study was to compare the tibiofemoral contact area and pressure after single-bundle (SB) and double-bundle (DB) anterior cruciate ligament (ACL) reconstruction by use of 2 femoral and 2 tibial tunnels in intact cadaveric knees. Tibiofemoral contact area and mean and maximum pressures were measured by pressure-sensitive film (Fujifilm, Valhalla, NY) inserted between the tibia and femur. The knee was subjected to a 1,000-N axial load by use of a uniaxial testing machine at 0 degrees , 15 degrees , 30 degrees , and 45 degrees of flexion. Three conditions were evaluated: (1) intact ACL, (2) SB ACL reconstruction (n = 10 knees), and (3) DB ACL reconstruction (n = 9 knees). When compared with the intact knee, DB ACL reconstruction showed no significant difference in tibiofemoral contact area and mean and maximum pressures. SB ACL reconstruction had a significantly smaller contact area on the lateral and medial tibiofemoral joints at 30 degrees and 15 degrees of flexion. SB ACL reconstruction also had significantly higher mean pressures at 15 degrees of flexion on the medial tibiofemoral joint and at 0 degrees and 15 degrees of flexion on the lateral tibiofemoral joint, as well as significantly higher maximum pressures at 15 degrees of flexion on the lateral tibiofemoral joint. SB ACL reconstruction resulted in a significantly smaller tibiofemoral contact area and higher pressures. DB ACL more closely restores the normal contact area and pressure mainly at low flexion angles. Our findings suggest that the changes in the contact area and pressures after SB ACL reconstruction may be one of the causes of osteoarthritis on long-term follow-up. DB ACL reconstruction may reduce the incidence of osteoarthritis by closely restoring contact area and pressure.
Charge loss between contacts of CdZnTe pixel detectors
International Nuclear Information System (INIS)
Bolotnikov, A.E.; Cook, W.R.; Harrison, F.A.; Wong, A.-S.; Schindler, S.M.; Eichelberger, A.C.
1999-01-01
The surface of Cd 1-x Zn x Te (CZT) material has high resistivity but is not a perfect dielectric. Even a small surface conductivity can affect the electric field distribution, and therefore, the charge collection efficiency of a CZT pixel detector. The paper describes studies of this phenomenon for several contact configurations made on a single CZT detector. We have determined the maximum inter-contact separation at which the surface inter-pixel charge loss can be neglected. (author)
Methylisothiazolinone in rinse-off products causes allergic contact dermatitis
DEFF Research Database (Denmark)
Yazar, K; Lundov, Michael Dyrgaard; Faurschou, A
2015-01-01
the potential to cause allergic contact dermatitis. METHODS: Nineteen MI-allergic subjects and 19 controls without MI allergy applied two liquid hand soaps five times per day on areas of 5 × 10 cm(2) on the ventral side of their forearms. One soap contained 100 ppm MI, the maximum allowed concentration......BACKGROUND: In recent years, the prevalence of contact allergy to the preservative methylisothiazolinone (MI) has increased dramatically. Cosmetic products are one of the major sources of exposure. OBJECTIVES: To examine whether allowed concentrations of MI in cosmetic rinse-off products have...
Measurement of Capillary Radius and Contact Angle within Porous Media.
Ravi, Saitej; Dharmarajan, Ramanathan; Moghaddam, Saeed
2015-12-01
The pore radius (i.e., capillary radius) and contact angle determine the capillary pressure generated in a porous medium. The most common method to determine these two parameters is through measurement of the capillary pressure generated by a reference liquid (i.e., a liquid with near-zero contact angle) and a test liquid. The rate of rise technique, commonly used to determine the capillary pressure, results in significant uncertainties. In this study, we utilize a recently developed technique for independently measuring the capillary pressure and permeability to determine the equivalent minimum capillary radii and contact angle of water within micropillar wick structures. In this method, the experimentally measured dryout threshold of a wick structure at different wicking lengths is fit to Darcy's law to extract the maximum capillary pressure generated by the test liquid. The equivalent minimum capillary radii of different wick geometries are determined by measuring the maximum capillary pressures generated using n-hexane as the working fluid. It is found that the equivalent minimum capillary radius is dependent on the diameter of pillars and the spacing between pillars. The equivalent capillary radii of micropillar wicks determined using the new method are found to be up to 7 times greater than the current geometry-based first-order estimates. The contact angle subtended by water at the walls of the micropillars is determined by measuring the capillary pressure generated by water within the arrays and the measured capillary radii for the different geometries. This mean contact angle of water is determined to be 54.7°.
Charge loss between contacts of CdZnTe pixel detectors
Bolotnikov, A E; Harrison, F A; Wong, A S; Schindler, S M; Eichelberger, A C
1999-01-01
The surface of Cd sub 1 sub - sub x Zn sub x Te (CZT) material has high resistivity but is not a perfect dielectric. Even a small surface conductivity can affect the electric field distribution, and therefore, the charge collection efficiency of a CZT pixel detector. The paper describes studies of this phenomenon for several contact configurations made on a single CZT detector. We have determined the maximum inter-contact separation at which the surface inter-pixel charge loss can be neglected. (author)
Shot Noise Suppression in a Quantum Point Contact with Short Channel Length
International Nuclear Information System (INIS)
Jeong, Heejun
2015-01-01
An experimental study on the current shot noise of a quantum point contact with short channel length is reported. The experimentally measured maximum energy level spacing between the ground and the first excited state of the device reached up to 7.5 meV, probably due to the hard wall confinement by using shallow electron gas and sharp point contact geometry. The two-dimensional non-equilibrium shot noise contour map shows noise suppression characteristics in a wide range of bias voltage. Fano factor analysis indicates spin-polarized transport through a short quantum point contact. (paper)
Solar cell contact pull strength as a function of pull-test temperature
Yasui, R. K.; Berman, P. A.
1972-01-01
Four types of solar cell contacts were given pull-strength tests at temperatures between -173 and +165 C. Contacts tested were: (1) solder-coated titanium-silver contacts on n-p cells, (2) palladium-containing titanium-silver contacts on n-p cells, (3) titanium-silver contacts on 0.2-mm-thick n-p cells, and (4) solder-coated electroless-nickel-plated contacts on p-n cells. Maximum pull strength was demonstrated at temperatures significantly below the air mass zero cell equilibrium temperature of +60 C. At the lowest temperatures, the chief failure mechanism was silicon fracture along crystallographic planes; at the highest temperatures, it was loss of solder strength. In the intermediate temperatures, many failure mechanisms operated. Pull-strength tests give a good indication of the suitability of solar cell contact systems for space use. Procedures used to maximize the validity of the results are described.
Essential Oil of Amomum maximum Roxb. and Its Bioactivities against Two Stored-Product Insects.
Guo, Shan-Shan; You, Chun-Xue; Liang, Jun-Yu; Zhang, Wen-Juan; Yang, Kai; Geng, Zhu-Feng; Wang, Cheng-Fang; Du, Shu-Shan; Lei, Ning
2015-01-01
Amomum maximum Roxb. is a perennial herb distributed in South China and Southeast Asia. The objective of this work was to analyze the chemical constituents and assess insecticidal and repellent activities of the essential oil from Amomum maximum fruits against Tribolium castaneum (Herbst) and Liposcelis bostrychophila (Badonnel). The essential oil was obtained by hydrodistillation and analyzed by gas chromatography-flame ionization detector and gas chromatography-mass spectrometry. The main components of the essential oil were identified to be β-pinene (23.39%), β-caryophyllene (16.43%), α-pinene (7.55%), sylvestrene (6.61%) and ç-cadinene (4.19%). It was found that the essential oil of A. maximum fruits possessed contact and fumigant toxicities against T. castaneum adults (LD50 = 29.57 μg/adult and LC(50) = 23.09 mg/L air, respectively) and showed contact toxicity against L. bostrychophila (LD(50) = 67.46 μg/cm(2)). Repellency of the crude oil was also evaluated. After 2 h treatment, the essential oil possessed 100% repellency at 78.63 nL/cm(2) against T. castaneum and 84% repellency at 63.17 nL/cm(2) against L. bostrychophila. The results indicated that the essential oil of A. maximum fruits had the potential to be developed as a natural insecticide and repellent for control of T. castaneum and L. bostrychophila.
Factors influencing bacterial adhesion to contact lenses.
Dutta, Debarun; Cole, Nerida; Willcox, Mark
2012-01-01
The process of any contact lens related keratitis generally starts with the adhesion of opportunistic pathogens to contact lens surface. This article focuses on identifying the factors which have been reported to affect bacterial adhesion to contact lenses. Adhesion to lenses differs between various genera/species/strains of bacteria. Pseudomonas aeruginosa, which is the predominant causative organism, adheres in the highest numbers to both hydrogel and silicone hydrogel lenses in vitro. The adhesion of this strain reaches maximum numbers within 1h in most in vitro studies and a biofilm has generally formed within 24 h of cells adhering to the lens surface. Physical and chemical properties of contact lens material affect bacterial adhesion. The water content of hydroxyethylmethacrylate (HEMA)-based lenses and their iconicity affect the ability of bacteria to adhere. The higher hydrophobicity of silicone hydrogel lenses compared to HEMA-based lenses has been implicated in the higher numbers of bacteria that can adhere to their surfaces. Lens wear has different effects on bacterial adhesion, partly due to differences between wearers, responses of bacterial strains and the ability of certain tear film proteins when bound to a lens surface to kill certain types of bacteria.
Calculation of force and time of contact formation at diffusion metal joining
Energy Technology Data Exchange (ETDEWEB)
Sukhanov, V E [Tsentral' nyj Nauchno-Issledovatel' skij Inst. Chernoj Metallurgii, Moscow (USSR); Grushevskij, A V [Moskovskij Stankoinstrumental' nyj Inst., Moscow (USSR); Surovtsev, A P
1989-03-01
An analytical model of contact for mation at diffusion joining is suggested. It is based on the introduction of a rough surface with roughnesses in the form of absolutely rigid spherical segnunts into a smooth laminar body. Mathematical expressions, permitting to calculate maximum welding force (pressure) providing close contact of the surfaces welded and time for contact formation between rough surfaces joined, are obtained. Divergence of calculational and experimental data does not exceed 20%. It is confirmed that the most intensive formation of joining occurs in the initial period of welding -the stage of formation of a physical contact, when deformation processes proceed in tensively. Finite formation of a strength joint occurs at the stage of diffusion interaction.
Riise, C; Sheikholeslam, A
1982-09-01
The effects of an intercuspal occlusal interference on the pattern of postural activity of the anterior temporal and masseter muscles were studied in eleven volunteers with complete, natural dentitions. The results indicate that, in man, there is postural activity in the anterior temporal and sometimes in the masseter muscles. The pattern of postural activity is influenced by the occurrence of an experimental occlusal interference, sometimes as early as 1 h after the insertion. After 48 h there was a significant increase of the activity in the anterior temporal muscles. This increased activity persisted until the interference was removed 1 week later and had almost disappeared 1 week after the removal.
Kern, Andrew M; Anderson, Donald D
2015-09-18
Acute injury severity, altered joint kinematics, and joint incongruity are three important mechanical factors linked to post-traumatic osteoarthritis (PTOA). Finite element analysis (FEA) was previously used to assess the influence of increased contact stress due to joint incongruity on PTOA development. While promising agreement with PTOA development was seen, the inherent complexities of contact FEA limited the numbers of subjects that could be analyzed. Discrete element analysis (DEA) is a simplified methodology for contact stress computation, which idealizes contact surfaces as a bed of independent linear springs. In this study, DEA was explored as an expedited alternative to FEA contact stress exposure computation. DEA was compared to FEA using results from a previously completed validation study of two cadaveric human ankles, as well as a previous study of post-operative contact stress exposure in 11 patients with tibial plafond fracture. DEA-computed maximum contact stresses were within 19% of those experimentally measured, with 90% of the contact area having computed contact stress values within 1MPa of those measured. In the 11 fractured ankles, maximum contact stress and contact area differences between DEA and FEA were 0.85 ± 0.64 MPa and 22.5 ± 11.5mm(2). As a predictive measure for PTOA development, both DEA and FEA had 100% concordance with presence of OA (KL grade ≥ 2) and >95% concordance with KL grade at 2 years. These results support DEA as a reasonable alternative to FEA for computing contact stress exposures following surgical reduction of a tibial plafond fracture. Copyright © 2015 Elsevier Ltd. All rights reserved.
Frictionless contact analysis of a functionally graded piezoelectric layered half-plane
International Nuclear Information System (INIS)
Ke Liaoliang; Yang Jie; Kitipornchai, Sritawat; Wang Yuesheng
2008-01-01
This paper investigates the frictionless contact problem of a layered half-plane made of functionally graded piezoelectric material (FGPM) in the plane strain state under the action of a rigid punch whose shape may be flat, triangular or cylindrical. It is assumed that the punch is a perfect electrical insulator with zero electric charge distribution. The electroelastic properties of the FGPM layer vary exponentially along the thickness direction. By using the Fourier integral transform technique, the problem is reduced to a Cauchy singular integral equation which is then numerically solved to determine the contact pressure, contact region, maximum indentation depth, normal stress, electrical potential and electric displacement fields. The stress intensity factor is also given to quantitatively characterize the singularity behavior of the contact pressure at the ends of a flat and triangular punch. Numerical results show that both the material property gradient of the FGPM layer and the punch geometry have a significant influence on the contact performance of the FGPM layered half-plane
Effect of Tabor parameter on hysteresis losses during adhesive contact
Ciavarella, M.; Greenwood, J. A.; Barber, J. R.
2017-01-01
The Tabor parameter μ is conventionally assumed to determine the range of applicability of the classical 'JKR' solution for adhesive elastic contact of a sphere and a plane, with the variation of the contact area and approach with load, and in particular the maximum tensile force (the pull-off force) being well predicted for μ > 5 . Here we show that the hysteretic energy loss during a contact separation cycle is significantly overestimated by the JKR theory, even at quite large values of μ. This stems from the absence of long-range tensile forces in the JKR theory, which implies that jump into contact is delayed until the separation α = 0 . We develop an approximate solution based on the use of Wu's solution with van der Waals interactions for jump-in, and the JKR theory for jump out of contact, and show that for μ > 5 , the predicted hysteresis loss is then close to that found by direct numerical solutions using the Lennard-Jones force law. We also show how the same method can be adapted to allow for contact between bodies with finite support stiffness.
Precision of jaw-closing movements for different jaw gaps.
Hellmann, Daniel; Becker, Georg; Giannakopoulos, Nikolaos N; Eberhard, Lydia; Fingerhut, Christopher; Rammelsberg, Peter; Schindler, Hans J
2014-02-01
Jaw-closing movements are basic components of physiological motor actions precisely achieving intercuspation without significant interference. The main purpose of this study was to test the hypothesis that, despite an imperfect intercuspal position, the precision of jaw-closing movements fluctuates within the range of physiological closing movements indispensable for meeting intercuspation without significant interference. For 35 healthy subjects, condylar and incisal point positions for fast and slow jaw-closing, interrupted at different jaw gaps by the use of frontal occlusal plateaus, were compared with uninterrupted physiological jaw closing, with identical jaw gaps, using a telemetric system for measuring jaw position. Examiner-guided centric relation served as a clinically relevant reference position. For jaw gaps ≤4 mm, no significant horizontal or vertical displacement differences were observed for the incisal or condylar points among physiological, fast, and slow jaw-closing. However, the jaw positions under these three closing conditions differed significantly from guided centric relation for nearly all experimental jaw gaps. The findings provide evidence of stringent neuromuscular control of jaw-closing movements in the vicinity of intercuspation. These results might be of clinical relevance to occlusal intervention with different objectives. © 2013 Eur J Oral Sci.
Effect of the cut off frequency on rough point and flat surface contacts
International Nuclear Information System (INIS)
Meng, Fan Ming
2012-01-01
In the past years, contact between two bodies has been studied from various ways that do not consider the cut off frequency effect on the contact mechanism. This paper reports the correlation between rough point contact and flat surface contact at different cut off frequencies of filter. The similarity and difference between the two types of contact mechanisms are presented for materials with linear or elastic perfectly plastic deformation. The conjugate gradient method (CGM) is used for analysing the rough point contact, while the rough flat surface contact is studied with an improved CGM in which the influence coefficient for the elastic deformation of the rough flat surface is obtained with finite element method. Numerical results show that for the above two types of contacts, their von Mises stress and maximum shear stress are greatly affected by the cut-off frequency of a high pass filter. Moreover, a decrease in the cut-off frequency leads to an increase in the contact area and a decrease in the approach for the rough flat surface contact, while the opposite variations is for the point contact between rough bodies with the small radii
In vivo cartilage contact deformation in the healthy human tibiofemoral joint.
Bingham, J T; Papannagari, R; Van de Velde, S K; Gross, C; Gill, T J; Felson, D T; Rubash, H E; Li, G
2008-11-01
In vivo cartilage contact deformation is instrumental for understanding human joint function and degeneration. This study measured the total deformation of contacting articular cartilage in the human tibiofemoral joint during in vivo weight-bearing flexion. Eleven healthy knees were magnetic resonance (MR) scanned and imaged with a dual fluoroscopic system while the subject performed a weight-bearing single-leg lunge. The tibia, femur and associated articulating cartilage were constructed from the MR images and combined with the dual fluoroscopic images to determine in vivo cartilage contact deformation from full extension to 120 degrees of flexion. In both compartments, minimum peak compartmental contact deformation occurred at 30 degrees of flexion (24 +/- 6% medial, 17 +/- 7% lateral) and maximum peak compartmental deformation occurred at 120 degrees of flexion (30 +/- 13% medial, 30 +/- 10% lateral) during the weight-bearing flexion from full extension to 120 degrees. Average medial contact areas and peak contact deformations were significantly greater than lateral compartment values (P In addition, cartilage thickness in regions of contact was on average 1.4- and 1.1-times thicker than the average thickness of the tibial and femoral cartilage surfaces, respectively (P line knowledge for investigating the effects of various knee injuries on joint contact biomechanics and the aetiology of cartilage degeneration.
Mink, Justine E.
2013-11-25
We show that contact engineering plays an important role to extract the maximum performance from energy harvesters like microbial fuel cells (MFCs). We experimented with Schottky and Ohmic methods of fabricating contact areas on silicon in an MFC contact material study. We utilized the industry standard contact material, aluminum, as well as a metal, whose silicide has recently been recognized for its improved performance in smallest scale integration requirements, cobalt. Our study shows that improvements in contact engineering are not only important for device engineering but also for microsystems. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Occupational contact urticaria and protein contact dermatitis.
Doutre, Marie-Sylvie
2005-01-01
Irritant dermatitis and eczema are the most prevalent occupational skin diseases. Less common are immediate contact reactions such as contact urticaria and protein contact dermatitis. Occupational contact urticaria can be subdivided into two categories, immunological and non immunological. However, some agents can induce these two types of reactions. Contact urticaria to natural rubber latex is particularly frequent among health care personnel, but contact urticaria to a wide variety of other substances occurs in many other occupations. Among those at risk are cooks, bakers, butchers, restaurant personnel, veterinarians, hairdressers, florists, gardeners, and forestry workers. Protein contact dermatitis in some of these occupations is caused principally by proteins of animal or plant origin, especially among individuals with a history of atopic dermatitis. Diagnosis requires careful interrogation, clinical examination and skin tests (open tests and prick tests with immediate lecture) to identify a particular contact allergen.
International Nuclear Information System (INIS)
Lee, L.Y.W.; Chen, J.C.; Nelson, R.A.
1984-01-01
Objective was to apply the technique of using a microthermocouple flush-mounted at the boiling surface for the measurement of the local-surface-temperature history in film and transition boiling on high temperature surfaces. From this measurement direct liquid-solid contact in film and transition boiling regimes was observed. In pool boiling of saturated, distilled, deionized water on an aluminum-coated copper surface, the time-averaged, local-liquid-contact fraction increased with decreasing surface superheat. Average contact duration increased monotonically with decreasing surface superheat, while frequency of liquid contact reached a maximum of approx. 50 contacts/s at a surface superheat of approx. 100 K and decreased gradually to 30 contacts/s near the critical heat flux. The liquid-solid contact duration distribution was dominated by short contacts 4 ms at low surface superheats, passing through a relatively flat contact duration distribution at about 80 0 K. Results of this paper indicate that liquid-solid contacts may be the dominant mechanism for energy transfer in the transition boiling process
Which soft contact lens power is better for piggyback fitting in keratoconus?
Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; Flores-Rodríguez, Patricia; González-Méijome, Jose Manuel
2013-02-01
To evaluate the impact of differente soft contact lens power in the anterior corneal curvature and regularity in subjects with keratoconus. Nineteen subjects (30 eyes) with keratoconus were included in the study. Six corneal topographies were taken with Pentacam Eye System over the naked eye and successively with soft lens (Senofilcon A) powers of -3.00, -1.50, 0.00, +1.50 and +3.00 D. Corneal measurements of mean central keratometry (MCK), maximum tangential curvature (TK), maximum front elevation (MFE) and eccentricity (Ecc) at 6 and 8 mm diameters as well as anterior corneal surface high order aberrations (i.e. total RMS, spherical- and coma-like and secondary astigmatism) were evaluated. Negative- and plano-powered soft lenses flattened (ppowered lenses did not induce any significant changes (p>0.05 in all cases) in MCK in comparison to the naked eye. The TK power decreased with negative lenses (psoft lens power in comparison to the naked eye (p>0.05 in all cases). Corneal eccentricity increased at 8 mm diameter for all lens powers (p0.05). Statistically differences were found in coma-like and secondary astigmatism (both ppowered soft contact lenses provide a flatter anterior surface in comparison to positive-powered lenses in subjects with keratoconus and thus they might be more suitable for piggyback contact lens fitting. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Aspects Concerning Modelling Contact Pressure of Polymeric Materials Used in Robotic Soft Elements
Directory of Open Access Journals (Sweden)
Florina-Carmen Ciornei
2015-06-01
Full Text Available Compliant materials are used in applications of robotics for final elements of robotic systems. Contact pressure between a spherical indenter and a linear viscoelastic halfspace is modeled for a cosine normal load. The Maxwell viscoelastic halfspace is described by relaxation function and creep function. For the working frequency domain, the material does not present obvious relaxation. Only for very low frequencies, the pressure variation presents a maximum during approaching delayed with respect to maximum force
Yang, C.; Persson, B. N. J.
2007-01-01
We report a molecular dynamics study of the contact between a rigid solid with a randomly rough surface and an elastic block with a flat surface. We study the contact area and the interfacial separation from small contact (low load) to full contact (high load). For small load the contact area varies linearly with the load and the interfacial separation depends logarithmically on the load. For high load the contact area approaches to the nominal contact area (i.e., complete contact), and the i...
Contact angle control of sessile drops on a tensioned web
Park, Janghoon; Kim, Dongguk; Lee, Changwoo
2018-04-01
In this study, the influence of the change of tension applied to flexible and thin web substrate on the contact angle of sessile drop in roll-to-roll system was investigated. Graphene oxide and deionized water solutions were used in the experiments. Tension was changed to 29, 49, and 69 N, and the casting distance of the micropipette and the material was set to 10, 20, and 40 mm, and the droplet volume was set to 10, 20, and 30 μL, respectively. Statistical analysis of three variables and analysis of the variance methodology showed that the casting distance was most significant for the contact angle change, and the most interesting tension variable was also affected. The change in tension caused the maximum contact angle to change by 5.5°. The tension was not uniform in the width direction. When the droplet was applied in the same direction in the width direction, it was confirmed that the tension unevenness had great influence on the contact angle up to 11°. Finally, the casting distance, which has a large effect on the contact angle, was calibrated in the width direction to reduce the width direction contact angle deviation to 1%. This study can be applied to fine patterning research using continuous inkjet printing and aerosol jet printing, which are roll-to-roll processes based on droplet handling.
Dynamic characterization of contact interactions of micro-robotic leg structures
Ryou, Jeong Hoon; Oldham, Kenn Richard
2014-05-01
Contact dynamics of microelectromechanical systems (MEMS) are typically complicated and it is consequently difficult to model all dynamic characteristics observed in time-domain responses involving impact. This issue becomes worse when a device, such as a mobile micro-robot, is not clamped to a substrate and has a complex mechanical structure. To characterize such a contact interaction situation, two walking micro-robot prototypes are tested having intentionally simple structures with different dimensions (21.2 mm × 16.3 mm × 0.75 mm and 32 mm × 25.4 mm × 4.1 mm) and weights (0.16 and 2.7 g). Contact interaction behaviors are characterized by analyzing experimental data under various excitation signals. A numerical approach was used to derive a novel contact model consisting of a coefficient of restitution matrix that uses modal vibration information. Experimental validation of the simulation model shows that it captures various dynamic features of the contact interaction when simulating leg behavior more accurately than previous contact models, such as single-point coefficient of restitution or compliant ground models. In addition, this paper shows that small-scale forces can be added to the simulation to improve model accuracy, resulting in average errors across driving conditions on the order of 2-6% for bounce frequency, maximum foot height, and average foot height, although there is substantial variation from case to case.
Correa, Nekane; Vadillo, Ernesto G.; Santamaria, Javier; Blanco-Lorenzo, Julio
2018-01-01
This study investigates the influence on the wheel-rail contact forces of the running speed and the shape and position of weld defects along the track. For this purpose, a vertical dynamic model in the space domain is used. The model is obtained from the transformation between the domains of frequency and space using a Rational Fraction Polynomials (RFP) method, which is modified with multiobjective genetic algorithms in order to improve the fitting of track receptance and to assist integration during simulations. This produces a precise model with short calculation times, which is essential to this study. The wheel-rail contact is modelled using a non-linear Hertz spring. The contact forces are studied for several types of characteristic welds. The way in which forces vary as a function of weld position and running speed is studied for each type of weld. This paper studies some of the factors that affect the maximum forces when the vehicle moves over a rail weld, such as weld geometry, parametric excitation and contact stiffness. It is found that the maximum force in the wheel-rail contact when the vehicle moves over a weld is not always proportional to the running speed. The paper explains why it is not proportional in specific welds.
Martinelli, Nicolo; Baretta, Silvia; Pagano, Jenny; Bianchi, Alberto; Villa, Tomaso; Casaroli, Gloria; Galbusera, Fabio
2017-11-25
Mobile-bearing ankle implants with good clinical results continued to increase the popularity of total ankle arthroplasty to address endstage ankle osteoarthritis preserving joint movement. Alternative solutions used fixed-bearing designs, which increase stability and reduce the risk of bearing dislocation, but with a theoretical increase of contact stresses leading to a higher polyethylene wear. The purpose of this study was to investigate the contact stresses, pressure and area in the polyethylene component of a new total ankle replacement with a fixed-bearing design, using 3D finite element analysis. A three-dimensional finite element model of the Zimmer Trabecular Metal Total Ankle was developed and assembled based on computed tomography images. Three different sizes of the polyethylene insert were modeled, and a finite element analysis was conducted to investigate the contact pressure, the von Mises stresses and the contact area of the polyethylene component during the stance phase of the gait cycle. The peak value of pressure was found in the anterior region of the articulating surface, where it reached 19.8 MPa at 40% of the gait cycle. The average contact pressure during the stance phase was 6.9 MPa. The maximum von Mises stress of 14.1 MPa was reached at 40% of the gait cycle in the anterior section. In the central section, the maximum von Mises stress of 10.8 MPa was reached at 37% of the gait cycle, whereas in the posterior section the maximum stress of 5.4 MPa was reached at the end of the stance phase. The new fixed-bearing total ankle replacement showed a safe mechanical behavior and many clinical advantages. However, advanced models to quantitatively estimate the wear are need. To the light of the clinical advantages, we conclude that the presented prosthesis is a good alternative to the other products present in the market.
Inferring Pairwise Interactions from Biological Data Using Maximum-Entropy Probability Models.
Directory of Open Access Journals (Sweden)
Richard R Stein
2015-07-01
Full Text Available Maximum entropy-based inference methods have been successfully used to infer direct interactions from biological datasets such as gene expression data or sequence ensembles. Here, we review undirected pairwise maximum-entropy probability models in two categories of data types, those with continuous and categorical random variables. As a concrete example, we present recently developed inference methods from the field of protein contact prediction and show that a basic set of assumptions leads to similar solution strategies for inferring the model parameters in both variable types. These parameters reflect interactive couplings between observables, which can be used to predict global properties of the biological system. Such methods are applicable to the important problems of protein 3-D structure prediction and association of gene-gene networks, and they enable potential applications to the analysis of gene alteration patterns and to protein design.
How pinning and contact angle hysteresis govern quasi-static liquid drop transfer.
Chen, H; Tang, T; Zhao, H; Law, K-Y; Amirfazli, A
2016-02-21
This paper presents both experimental and numerical simulations of liquid transfer between two solid surfaces with contact angle hysteresis (CAH). Systematic studies on the role of the advancing contact angle (θa), receding contact angle (θr) and CAH in determining the transfer ratio (volume of the liquid transferred onto the acceptor surface over the total liquid volume) and the maximum adhesion force (Fmax) were performed. The transfer ratio was found to be governed by contact line pinning at the end of the transfer process caused by CAH of surfaces. A map based on θr of the two surfaces was generated to identify the three regimes for liquid transfer: (I) contact line pinning occurs only on the donor surface, (II) contact line pinning occurs on both surfaces, and (III) contact line pinning occurs only on the acceptor surface. With this map, an empirical equation is provided which is able to estimate the transfer ratio by only knowing θr of the two surfaces. The value of Fmax is found to be strongly influenced by the contact line pinning in the early stretching stage. For symmetric liquid bridges between two identical surfaces, Fmax may be determined only by θa, only by θr, or by both θa and θr, depending on the magnitude of the contact angles. For asymmetric bridges, Fmax is found to be affected by the period when contact lines are pinned on both surfaces.
Contact angle and local wetting at contact line.
Li, Ri; Shan, Yanguang
2012-11-06
This theoretical study was motivated by recent experiments and theoretical work that had suggested the dependence of the static contact angle on the local wetting at the triple-phase contact line. We revisit this topic because the static contact angle as a local wetting parameter is still not widely understood and clearly known. To further clarify the relationship of the static contact angle with wetting, two approaches are applied to derive a general equation for the static contact angle of a droplet on a composite surface composed of heterogeneous components. A global approach based on the free surface energy of a thermodynamic system containing the droplet and solid surface shows the static contact angle as a function of local surface chemistry and local wetting state at the contact line. A local approach, in which only local forces acting on the contact line are considered, results in the same equation. The fact that the local approach agrees with the global approach further demonstrates the static contact angle as a local wetting parameter. Additionally, the study also suggests that the wetting described by the Wenzel and Cassie equations is also the local wetting of the contact line rather than the global wetting of the droplet.
[Sport injuries in full contact and semi-contact karate].
Greier, K; Riechelmann, H; Ziemska, J
2014-03-01
Karate enjoys great popularity both in professional and recreational sports and can be classified into full, half and low contact styles. The aim of this study was the analysis of sports injuries in Kyokushinkai (full contact) and traditional Karate (semi-contact). In a retrospective study design, 215 active amateur karateka (114 full contact, 101 semi-contact) were interviewed by means of a standardised questionnaire regarding typical sport injuries during the last 36 months. Injuries were categorised into severity grade I (not requiring medical treatment), grade II (single medical treatment), grade III (several outpatient medical treatments) and grade IV (requiring hospitalisation). In total, 217 injuries were reported in detail. 125 injuries (58%) occurred in full contact and 92 (42%) in semi-contact karate. The time related injury rate of full contact karateka was 1.9/1000 h compared to 1.3/1000 h of semi-contact karateka (p injuries were musculoskeletal contusions (33% full contact, 20% semi-contact), followed by articular sprains with 19% and 16%. The lower extremity was affected twice as often in full contact (40%) as in semi-contact (20%) karate. Training injuries were reported by 80% of the full contact and 77% of the semi-contact karateka. Most injuries, both in training and competition, occurred in kumite. 75% of the reported injuries of full contact and 70% of semi-contact karateka were classified as low grade (I or II). The high rate of injuries during training and kumite (sparring) points to specific prevention goals. The emphasis should be put on proprioceptive training and consistent warm-up. In the actual competition the referees play a vital role regarding prevention. © Georg Thieme Verlag KG Stuttgart · New York.
Understanding channel and contact effects on transport in 1-dimensional nanotransistors.
Energy Technology Data Exchange (ETDEWEB)
Swartzentruber, Brian S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Delker, Collin James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Yoo, Jinkyoung [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Janes, David B. [Purdue Univ., West Lafayette, IN (United States)
2015-02-01
Nanowire transistors are generally formed by metal contacts to a uniformly doped nanowire. The transistor can be modeled as a series combination of resistances from both the channel and the contacts. In this study, a simple model is proposed consisting of a resistive channel in series with two Schottky metal-semiconductor contacts modeled using the WKB approximation. This model captures several phenomena commonly observed in nanowire transistor measurements, including the mobility as a function of gate potential, mobility reduction with respect to bulk mobility, and non-linearities in output characteristics. For example, the maximum measured mobility as a function of gate voltage in a nanowire transistor can be predicted based on the semiconductor bulk mobility in addition to barrier height and other properties of the contact. The model is then extended to nanowires with axial p-n junctions having an inde- pendent gate over each wire segment by splitting the channel resistance into a series component for each doping segment. Finally, the contact-channel model is applied to low-frequency noise analysis in nanowire devices, where the noise can be generated in both the channel and the contacts. Because contacts play a major, yet often neglected, role in nanowire transistor operation, they must be accounted for in order to extract meaningful parameters from I-V and noise measurements.
Contacts, non-linear transport effects and failure in multi-walled carbon nanotubes
International Nuclear Information System (INIS)
Berger, C; Yi, Y; Gezo, J; Poncharal, P; Heer, W A de
2003-01-01
Pristine arc-produced multi-walled carbon nanotubes are contacted to liquid mercury in situ in a transmission electron microscope. The conductance G(V) for all tubes increases with increasing bias voltage V. This is related to the electronic density of the nanotubes. Similar G(V) behaviour is observed for HOPG-graphite contacted in air with Hg, with dG(V)/dV∼0.3G 0 . Variations observed in the conductance are related to nanotube-Hg contact effects. For tubes barely touching the Hg surface, the conductance is low (typically G(V=0)∼0.1-0.5G 0 ); G(V) may maximize around V=1.5-2 V or continue to increase linearly depending on the MWNT-Hg contact. For good contacts the maximum low-bias conductance is 1G 0 . Non-conducting tubes are observed having a low-bias conductance smaller than 10 -3 G 0 . High-voltage tube failure usually occurs at the contact with Hg for clean tubes, or at tube defects. An important phenomenon is the formation of a Hg bubble near the contact nanotube-Hg surface when the nanotube is negatively biased, under high bias current conditions, indicating the heating effect of hot electrons injected into the mercury
Accuracy of perioperative mandibular positions in orthognathic surgery.
Borba, A M; Ribeiro-Junior, O; Brozoski, M A; Cé, P S; Espinosa, M M; Deboni, M C Z; Miloro, M; Naclério-Homem, M G
2014-08-01
Mandibular position is an important parameter used for the diagnosis of dentofacial deformities, as well as for orthognathic surgery planning and execution. Centric relation (anterior and superior relationship of the mandibular condyles interposed by the thinnest portion of their disks against the articular eminencies), centric occlusion (when lower teeth contact upper teeth at centric relation), and maximal intercuspation (complete interdigitation of lower and upper teeth) are not often addressed as factors that influence the results of orthognathic surgery, although these relationships are critical to ensure accuracy during the surgery. The present study assessed occlusal measurements taken before and after the induction of general anaesthesia from consecutive orthognathic surgery subjects. The variables assessed included the differences between these occlusal measurements, patient age, gender, type of deformity, and type of proposed orthognathic surgical procedure. The results demonstrated statistically significant differences for mandibular retrusion from maximal intercuspation to centric occlusion position, whereas the mandible appeared not to change significantly from centric occlusion after the induction of general anaesthesia. Patient age and the type of deformity appeared to influence the results. While in most instances centric occlusion can be adequately reproduced under general anaesthesia, for some specific orthognathic cases more accurate results might be obtained if the mandible-first sequence is used. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
CONTACT ANGLE OF YUCCA MOUNTAIN WELDED TUFF WITH WATER AND BRINES
International Nuclear Information System (INIS)
H. Kalia
2006-01-01
A number of tests were performed to acquire contact angles between Yucca Mountain welded tuff from Topopah Springs Lower Lithophysal geologic unit and various brine solutions. The tests were performed on core disks received from Sample Management Facility (SMF), oven dried to a constant weight and the core disks vacuum saturated in: distilled water, J-13 water, calcium chloride brine and sodium chloride brine to constant weight. The contact angles were acquired from eight points on the surface of the core disks, four on rough surface, and four on polished surface. The contact angle was measured by placing a droplet of the test fluid, distilled water, J-13 water, calcium chloride brine and sodium chloride brine on the core disks. The objective of this test was to acquire contact angles as a potential input to estimating capillary forces in accumulated dust on the waste packages and drip shields slated for the proposed High-Level Radioactive Waste Repository at Yucca Mountain, Nevada. It was noted that once the droplet contacts the test surface, it continues to spread hence the contact angle continues to decrease with elapsed time. The maximum observed angle was at time 0 or when the drop contacted the rock surface. The measured contact angle, in all cases has significant scatter. In general, the time zero contact angles for core disks saturated in sodium chloride brine were smaller than those saturated in calcium chloride brine, distilled water, and J-13 water. The contact angles for samples saturated in distilled water, J-13 water and calcium chloride brine at time zero were similar. There was slight difference between the observed contact angles for smooth and rough surface of the test samples. The contact angles for smooth surfaces were smaller than for the rough surfaces
Contact and Non-contact Measurements of Grinding Pins
Directory of Open Access Journals (Sweden)
Magdziak Marek
2015-01-01
Full Text Available The paper presents the results of contact and non-contact measurements of external profiles of selected grinding pins. The measurements were conducted in order to choose the appropriate measuring technique in the case of the considered measurement task. In the case of contact measurements the coordinate measuring machine ACCURA II was applied. The used coordinate measuring machine was equipped with the contact scanning probe VAST XT and the Calypso inspection software. Contact coordinate measurements were performed by using of different measurement strategies. The applied strategies included different scanning velocities and distances between measured points. Non-contact measurements were conducted by means of the tool presetter produced by the Mahr company. On the basis of gained results the guidelines concerning measurements of grinding pins were formulated. The measurements of analyzed grinding pins performed by means of the non-contact measuring system are characterized by higher reproducibility than the contact measurements. The low reproducibility of contact measurements may be connected with the inaccuracy of the selected coordinate measuring machine and the measuring probe, the measurement parameters and environmental conditions in the laboratory where the coordinate measuring machine is located. Moreover, the paper presents the possible application of results of conducted investigations. The results of non-contact measurements can be used in the simulation studies of grinding processes. The simulations may reduce the costs of machining processes.
Experimental Investigations on Microshock Waves and Contact Surfaces
Kai, Yun; Garen, Walter; Teubner, Ulrich
2018-02-01
The present work reports on progress in the research of a microshock wave. Because of the lack of a good understanding of the propagation mechanism of the microshock flow system (shock wave, contact surface, and boundary layer), the current work concentrates on measuring microshock flows with special attention paid to the contact surface. A novel setup involving a glass capillary (with a 200 or 300 μ m hydraulic diameter D ) and a high-speed magnetic valve is applied to generate a shock wave with a maximum initial Mach number of 1.3. The current work applies a laser differential interferometer to perform noncontact measurements of the microshock flow's trajectory, velocity, and density. The current work presents microscale measurements of the shock-contact distance L that solves the problem of calculating the scaling factor Sc =Re ×D /(4 L ) (introduced by Brouillette), which is a parameter characterizing the scaling effects of shock waves. The results show that in contrast to macroscopic shock waves, shock waves at the microscale have a different propagation or attenuation mechanism (key issue of this Letter) which cannot be described by the conventional "leaky piston" model. The main attenuation mechanism of microshock flow may be the ever slower moving contact surface, which drives the shock wave. Different from other measurements using pressure transducers, the current setup for density measurements resolves the whole microshock flow system.
International Nuclear Information System (INIS)
Kim, Tae Young; Negash, Assmelash; Cho, Gyubaek
2017-01-01
Highlights: • A design concept of a direct contact thermoelectric generator (DCTEG) is proposed. • Power generation characteristics of the DCTEG on a diesel engine are examined. • Maximum power output of ∼45 W and conversion efficiency of ∼2.0% are obtained. • Effect of clearance on energy conversion of the DCTEG is numerically investigated. • A 132% increase in output power with a flush mounted configuration is obtained. - Abstract: This paper proposes the concept of a direct contact thermoelectric generator (DCTEG) to enhance the practicality and widen the application areas of thermoelectric generators (TEGs). In the DCTEG, one thermoelectric module (TEM) surface is directly exposed to a heat source, and the other surface is in direct contact with a coolant flow. The current direct-contact configuration is beneficial for system fabrication, maintenance, long-term reliability, and maximizing energy usage in cooperation with other energy systems because of its simple configuration and lack of interfaces between the TEMs and heat sources. In order to validate the proposed concept experimentally, a DCTEG was constructed by fabricating customized TEMs and exhaust gas and coolant channels with openings to mount the TEMs. A diesel engine served as a heat source by providing hot exhaust gas into the DCTEG, while the coolant (water–ethylene glycol mixture) was pumped into the coolant channels to remove heat. Based on the experimental results obtained under various engine operating conditions, the power generation of the DCTEG was characterized in the form of current–voltage and power–voltage curves. The maximum output power of 43 W and conversion efficiency of 2.0% were obtained under the highest engine load and rotation speed conditions. A series of numerical simulations was carried out to investigate the effect of the system configuration on the DCTEG power generation performance with the clearance between the TEM surfaces and exhaust gas
Takeuchi, Hisahiro; Bando, Eiichi; Abe, Susumu
2008-07-01
To establish standardized evaluating methods for jaw movements analysis. In this paper, we investigated evaluating parameters for 6 degree-of-freedom jaw movements data. Recorded data of jaw border movements from 20 male adults were employed as basic samples. The main parameters were as follows: 1. The displacement of an intercondylar midpoint: the length of a straight line between 2 positions of this point, the intercuspal position and other jaw position. 2. The angle of intercondylar axes: the angle between 2 position of the intercondylar axis, the intercuspal position and other jaw position. 3. The angle of incisal-condylar planes: the angle between 2 position of the plane, the intercuspal position and other jaw position (this plane was defined with the incisal point and condylar points of both sides 4. The mandibular motion range index: quantitative values calculated with 2 of 3 parameters described above. The mandibular motion range index showed a close correlation with respective projected areas of the incisal paths, with the projected area of sagittal border movements on the sagittal plane r = 0.82 (p movements on the frontal plane: left lateral border movements r = 0.92 (p movements r = 0.84 (p movements data and relative relationship between the intercuspal position and other jaw position. They were independent of reference coordinate systems and could measure jaw movement quantitatively.
Searl, Jeff; Knollhoff, Stephanie; Barohn, Richard J.
2017-01-01
Purpose: This preliminary study on lingual-alveolar contact pressures (LACP) in people with amyotrophic lateral sclerosis (ALS) had several aims: (a) to evaluate whether the protocol induced fatigue, (b) to compare LACP during speech (LACP-Sp) and during maximum isometric pressing (LACP-Max) in people with ALS (PALS) versus healthy controls, (c)…
Dynamic characterization of contact interactions of micro-robotic leg structures
International Nuclear Information System (INIS)
Ryou, Jeong Hoon; Oldham, Kenn Richard
2014-01-01
Contact dynamics of microelectromechanical systems (MEMS) are typically complicated and it is consequently difficult to model all dynamic characteristics observed in time-domain responses involving impact. This issue becomes worse when a device, such as a mobile micro-robot, is not clamped to a substrate and has a complex mechanical structure. To characterize such a contact interaction situation, two walking micro-robot prototypes are tested having intentionally simple structures with different dimensions (21.2 mm × 16.3 mm × 0.75 mm and 32 mm × 25.4 mm × 4.1 mm) and weights (0.16 and 2.7 g). Contact interaction behaviors are characterized by analyzing experimental data under various excitation signals. A numerical approach was used to derive a novel contact model consisting of a coefficient of restitution matrix that uses modal vibration information. Experimental validation of the simulation model shows that it captures various dynamic features of the contact interaction when simulating leg behavior more accurately than previous contact models, such as single-point coefficient of restitution or compliant ground models. In addition, this paper shows that small-scale forces can be added to the simulation to improve model accuracy, resulting in average errors across driving conditions on the order of 2–6% for bounce frequency, maximum foot height, and average foot height, although there is substantial variation from case to case. (paper)
Improving consensus contact prediction via server correlation reduction.
Gao, Xin; Bu, Dongbo; Xu, Jinbo; Li, Ming
2009-05-06
Protein inter-residue contacts play a crucial role in the determination and prediction of protein structures. Previous studies on contact prediction indicate that although template-based consensus methods outperform sequence-based methods on targets with typical templates, such consensus methods perform poorly on new fold targets. However, we find out that even for new fold targets, the models generated by threading programs can contain many true contacts. The challenge is how to identify them. In this paper, we develop an integer linear programming model for consensus contact prediction. In contrast to the simple majority voting method assuming that all the individual servers are equally important and independent, the newly developed method evaluates their correlation by using maximum likelihood estimation and extracts independent latent servers from them by using principal component analysis. An integer linear programming method is then applied to assign a weight to each latent server to maximize the difference between true contacts and false ones. The proposed method is tested on the CASP7 data set. If the top L/5 predicted contacts are evaluated where L is the protein size, the average accuracy is 73%, which is much higher than that of any previously reported study. Moreover, if only the 15 new fold CASP7 targets are considered, our method achieves an average accuracy of 37%, which is much better than that of the majority voting method, SVM-LOMETS, SVM-SEQ, and SAM-T06. These methods demonstrate an average accuracy of 13.0%, 10.8%, 25.8% and 21.2%, respectively. Reducing server correlation and optimally combining independent latent servers show a significant improvement over the traditional consensus methods. This approach can hopefully provide a powerful tool for protein structure refinement and prediction use.
Improving consensus contact prediction via server correlation reduction
Directory of Open Access Journals (Sweden)
Xu Jinbo
2009-05-01
Full Text Available Abstract Background Protein inter-residue contacts play a crucial role in the determination and prediction of protein structures. Previous studies on contact prediction indicate that although template-based consensus methods outperform sequence-based methods on targets with typical templates, such consensus methods perform poorly on new fold targets. However, we find out that even for new fold targets, the models generated by threading programs can contain many true contacts. The challenge is how to identify them. Results In this paper, we develop an integer linear programming model for consensus contact prediction. In contrast to the simple majority voting method assuming that all the individual servers are equally important and independent, the newly developed method evaluates their correlation by using maximum likelihood estimation and extracts independent latent servers from them by using principal component analysis. An integer linear programming method is then applied to assign a weight to each latent server to maximize the difference between true contacts and false ones. The proposed method is tested on the CASP7 data set. If the top L/5 predicted contacts are evaluated where L is the protein size, the average accuracy is 73%, which is much higher than that of any previously reported study. Moreover, if only the 15 new fold CASP7 targets are considered, our method achieves an average accuracy of 37%, which is much better than that of the majority voting method, SVM-LOMETS, SVM-SEQ, and SAM-T06. These methods demonstrate an average accuracy of 13.0%, 10.8%, 25.8% and 21.2%, respectively. Conclusion Reducing server correlation and optimally combining independent latent servers show a significant improvement over the traditional consensus methods. This approach can hopefully provide a powerful tool for protein structure refinement and prediction use.
An elastic-plastic contact model for line contact structures
Zhu, Haibin; Zhao, Yingtao; He, Zhifeng; Zhang, Ruinan; Ma, Shaopeng
2018-06-01
Although numerical simulation tools are now very powerful, the development of analytical models is very important for the prediction of the mechanical behaviour of line contact structures for deeply understanding contact problems and engineering applications. For the line contact structures widely used in the engineering field, few analytical models are available for predicting the mechanical behaviour when the structures deform plastically, as the classic Hertz's theory would be invalid. Thus, the present study proposed an elastic-plastic model for line contact structures based on the understanding of the yield mechanism. A mathematical expression describing the global relationship between load history and contact width evolution of line contact structures was obtained. The proposed model was verified through an actual line contact test and a corresponding numerical simulation. The results confirmed that this model can be used to accurately predict the elastic-plastic mechanical behaviour of a line contact structure.
Equilibrium contact angle or the most-stable contact angle?
Montes Ruiz-Cabello, F J; Rodríguez-Valverde, M A; Cabrerizo-Vílchez, M A
2014-04-01
It is well-established that the equilibrium contact angle in a thermodynamic framework is an "unattainable" contact angle. Instead, the most-stable contact angle obtained from mechanical stimuli of the system is indeed experimentally accessible. Monitoring the susceptibility of a sessile drop to a mechanical stimulus enables to identify the most stable drop configuration within the practical range of contact angle hysteresis. Two different stimuli may be used with sessile drops: mechanical vibration and tilting. The most stable drop against vibration should reveal the changeless contact angle but against the gravity force, it should reveal the highest resistance to slide down. After the corresponding mechanical stimulus, once the excited drop configuration is examined, the focus will be on the contact angle of the initial drop configuration. This methodology needs to map significantly the static drop configurations with different stable contact angles. The most-stable contact angle, together with the advancing and receding contact angles, completes the description of physically realizable configurations of a solid-liquid system. Since the most-stable contact angle is energetically significant, it may be used in the Wenzel, Cassie or Cassie-Baxter equations accordingly or for the surface energy evaluation. © 2013 Elsevier B.V. All rights reserved.
Contact detection acceleration in pebble flow simulation for pebble bed reactor systems
Energy Technology Data Exchange (ETDEWEB)
Li, Y.; Ji, W. [Department of Mechanical, Aerospace, and Nuclear Engineering Rensselaer, Polytechnic Institute, 110 8th street, Troy, NY 12180 (United States)
2013-07-01
Pebble flow simulation plays an important role in the steady state and transient analysis of thermal-hydraulics and neutronics for Pebble Bed Reactors (PBR). The Discrete Element Method (DEM) and the modified Molecular Dynamics (MD) method are widely used to simulate the pebble motion to obtain the distribution of pebble concentration, velocity, and maximum contact stress. Although DEM and MD present high accuracy in the pebble flow simulation, they are quite computationally expensive due to the large quantity of pebbles to be simulated in a typical PBR and the ubiquitous contacts and collisions between neighboring pebbles that need to be detected frequently in the simulation, which greatly restricted their applicability for large scale PBR designs such as PBMR400. Since the contact detection accounts for more than 60% of the overall CPU time in the pebble flow simulation, the acceleration of the contact detection can greatly enhance the overall efficiency. In the present work, based on the design features of PBRs, two contact detection algorithms, the basic cell search algorithm and the bounding box search algorithm are investigated and applied to pebble contact detection. The influence from the PBR system size, core geometry and the searching cell size on the contact detection efficiency is presented. Our results suggest that for present PBR applications, the bounding box algorithm is less sensitive to the aforementioned effects and has superior performance in pebble contact detection compared with basic cell search algorithm. (authors)
Contact detection acceleration in pebble flow simulation for pebble bed reactor systems
International Nuclear Information System (INIS)
Li, Y.; Ji, W.
2013-01-01
Pebble flow simulation plays an important role in the steady state and transient analysis of thermal-hydraulics and neutronics for Pebble Bed Reactors (PBR). The Discrete Element Method (DEM) and the modified Molecular Dynamics (MD) method are widely used to simulate the pebble motion to obtain the distribution of pebble concentration, velocity, and maximum contact stress. Although DEM and MD present high accuracy in the pebble flow simulation, they are quite computationally expensive due to the large quantity of pebbles to be simulated in a typical PBR and the ubiquitous contacts and collisions between neighboring pebbles that need to be detected frequently in the simulation, which greatly restricted their applicability for large scale PBR designs such as PBMR400. Since the contact detection accounts for more than 60% of the overall CPU time in the pebble flow simulation, the acceleration of the contact detection can greatly enhance the overall efficiency. In the present work, based on the design features of PBRs, two contact detection algorithms, the basic cell search algorithm and the bounding box search algorithm are investigated and applied to pebble contact detection. The influence from the PBR system size, core geometry and the searching cell size on the contact detection efficiency is presented. Our results suggest that for present PBR applications, the bounding box algorithm is less sensitive to the aforementioned effects and has superior performance in pebble contact detection compared with basic cell search algorithm. (authors)
Optimization of Contact Force and Pull-in Voltage for Series based MEMS Switch
Directory of Open Access Journals (Sweden)
Abhijeet KSHIRSAGAR
2010-04-01
Full Text Available Cantilever based metal-to-metal contact type MEMS series switch has many applications namely in RF MEMS, Power MEMS etc. A typical MEMS switch consists of a cantilever as actuating element to make the contact between the two metal terminals of the switch. The cantilever is pulled down by applying a pull-in voltage to the control electrode that is located below the middle portion of the cantilever while only the tip portion of the cantilever makes contact between the two terminals. Detailed analysis of bending of the cantilever for different pull-in voltages reveals some interesting facts. At low pull-in voltage the cantilever tip barely touches the two terminals, thus resulting in very less contact area. To increase contact area a very high pull-in voltage is applied, but it lifts the tip from the free end due to concave curving of the cantilever in the middle region of the cantilever where the electrode is located. Again it results in less contact area. Furthermore, the high pull-in voltage produces large stress at the base of the cantilever close to the anchor. Therefore, an optimum, pull-in voltage must exist at which the concave curving is eliminated and contact area is maximum. In this paper authors report the finding of optimum contact force and pull-in voltage.
In situ electric fields causing electro-stimulation from conductor contact of charged human
International Nuclear Information System (INIS)
Nagai, T.; Hirata, A.
2010-01-01
Contact currents flow from/into a human body when touching an object such as a metal structure with a different electric potential. These currents can stimulate muscle and peripheral nerves. In this context, computational analyses of in situ electric fields caused by the contact current have been performed, while their effectiveness for transient contact currents has not well been investigated. In the present study, using an anatomically based human model, a dispersive finite-difference time-domain model was utilised to computed transient contact current and in situ electric fields from a charged human. Computed in situ electric fields were highly localised in the hand. In order to obtain an insight into the relationship between in situ electric field and electro-stimulation, cell-maximum and 5-mm averaged in situ electric fields were computed and compared with strength-duration curves. The comparison suggests that both measures could be larger than thresholds derived from the strength- duration curves with parameters used in previous studies. (authors)
Reducing contact resistance in graphene devices through contact area patterning.
Smith, Joshua T; Franklin, Aaron D; Farmer, Damon B; Dimitrakopoulos, Christos D
2013-04-23
Performance of graphene electronics is limited by contact resistance associated with the metal-graphene (M-G) interface, where unique transport challenges arise as carriers are injected from a 3D metal into a 2D-graphene sheet. In this work, enhanced carrier injection is experimentally achieved in graphene devices by forming cuts in the graphene within the contact regions. These cuts are oriented normal to the channel and facilitate bonding between the contact metal and carbon atoms at the graphene cut edges, reproducibly maximizing "edge-contacted" injection. Despite the reduction in M-G contact area caused by these cuts, we find that a 32% reduction in contact resistance results in Cu-contacted, two-terminal devices, while a 22% reduction is achieved for top-gated graphene transistors with Pd contacts as compared to conventionally fabricated devices. The crucial role of contact annealing to facilitate this improvement is also elucidated. This simple approach provides a reliable and reproducible means of lowering contact resistance in graphene devices to bolster performance. Importantly, this enhancement requires no additional processing steps.
An investigation of rugby scrimmaging posture and individual maximum pushing force.
Wu, Wen-Lan; Chang, Jyh-Jong; Wu, Jia-Hroung; Guo, Lan-Yuen
2007-02-01
Although rugby is a popular contact sport and the isokinetic muscle torque assessment has recently found widespread application in the field of sports medicine, little research has examined the factors associated with the performance of game-specific skills directly by using the isokinetic-type rugby scrimmaging machine. This study is designed to (a) measure and observe the differences in the maximum individual pushing forward force produced by scrimmaging in different body postures (3 body heights x 2 foot positions) with a self-developed rugby scrimmaging machine and (b) observe the variations in hip, knee, and ankle angles at different body postures and explore the relationship between these angle values and the individual maximum pushing force. Ten national rugby players were invited to participate in the examination. The experimental equipment included a self-developed rugby scrimmaging machine and a 3-dimensional motion analysis system. Our results showed that the foot positions (parallel and nonparallel foot positions) do not affect the maximum pushing force; however, the maximum pushing force was significantly lower in posture I (36% body height) than in posture II (38%) and posture III (40%). The maximum forward force in posture III (40% body height) was also slightly greater than for the scrum in posture II (38% body height). In addition, it was determined that hip, knee, and ankle angles under parallel feet positioning are factors that are closely negatively related in terms of affecting maximum pushing force in scrimmaging. In cross-feet postures, there was a positive correlation between individual forward force and hip angle of the rear leg. From our results, we can conclude that if the player stands in an appropriate starting position at the early stage of scrimmaging, it will benefit the forward force production.
Effect of Ankle Joint Contact Angle and Ground Contact Time on Depth Jump Performance.
Phillips, Joshua H; Flanagan, Sean P
2015-11-01
Athletes often need to both jump high and get off the ground quickly, but getting off the ground quickly can decrease the vertical ground reaction force (VGRF) impulse, impeding jump height. Energy stored in the muscle-tendon complex during the stretch-shortening cycle (SSC) may mitigate the effects of short ground contact times (GCTs). To take advantage of the SSC, several coaches recommend "attacking" the ground with the foot in a dorsiflexed (DF) position at contact. However, the efficacy of this technique has not been tested. This investigation tested the hypotheses that shorter GCTs would lead to smaller vertical depth jump heights (VDJH), and that this difference could be mitigated by instructing the athletes to land in a DF as opposed to a plantar flexed (PF) foot position. Eighteen healthy junior college athletes performed depth jumps from a 45-cm box onto force platforms under instruction to achieve one of the 2 objectives (maximum jump height [hmax] or minimal GCT [tmin]), with one of the 2 foot conditions (DF or PF). These variations created 4 distinct jump conditions: DF-hmax, DF-tmin, PF-hmax, and PF-tmin. For all variables examined, there were no significant interactions. For all 4 conditions, the ankle was PF during landing, but the DF condition was 28.87% less PF than the PF condition. The tmin conditions had a 23.48% shorter GCT than hmax. There were no significant main effects for jump height. The peak impact force for tmin was 22.14% greater than hmax and 19.11% greater for DF compared with PF conditions. A shorter GCT did not necessitate a smaller jump height, and a less PF foot did not lead to improvements in jump height or contact time during a depth jump from a 45-cm box. The same jump height was attained in less PF and shorter GCT conditions by larger impact forces. To decrease contact time while maintaining jump height, athletes should be instructed to "get off the ground as fast as possible." This cue seems to be more important than foot
Modeling contact angle hysteresis of a liquid droplet sitting on a cosine wave-like pattern surface.
Promraksa, Arwut; Chen, Li-Jen
2012-10-15
A liquid droplet sitting on a hydrophobic surface with a cosine wave-like square-array pattern in the Wenzel state is simulated by using the Surface Evolver to determine the contact angle. For a fixed drop volume, multiple metastable states are obtained at two different surface roughnesses. Unusual and non-circular shape of the three-phase contact line of a liquid droplet sitting on the model surface is observed due to corrugation and distortion of the contact line by structure of the roughness. The contact angle varies along the contact line for each metastable state. The maximum and minimum contact angles among the multiple metastable states at a fixed viewing angle correspond to the advancing and the receding contact angles, respectively. It is interesting to observe that the advancing/receding contact angles (and contact angle hysteresis) are a function of viewing angle. In addition, the receding (or advancing) contact angles at different viewing angles are determined at different metastable states. The contact angle of minimum energy among the multiple metastable states is defined as the most stable (equilibrium) contact angle. The Wenzel model is not able to describe the contact angle along the three-phase contact line. The contact angle hysteresis at different drop volumes is determined. The number of the metastable states increases with increasing drop volume. Drop volume effect on the contact angles is also discussed. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.
Prioritized Contact Transport Stream
Hunt, Walter Lee, Jr. (Inventor)
2015-01-01
A detection process, contact recognition process, classification process, and identification process are applied to raw sensor data to produce an identified contact record set containing one or more identified contact records. A prioritization process is applied to the identified contact record set to assign a contact priority to each contact record in the identified contact record set. Data are removed from the contact records in the identified contact record set based on the contact priorities assigned to those contact records. A first contact stream is produced from the resulting contact records. The first contact stream is streamed in a contact transport stream. The contact transport stream may include and stream additional contact streams. The contact transport stream may be varied dynamically over time based on parameters such as available bandwidth, contact priority, presence/absence of contacts, system state, and configuration parameters.
Scheman, Andrew; Severson, David
2016-01-01
Data on the prevalence of contact allergy in North America are currently reported by groups of academic contact allergy specialists at select academic centers. Sampling of data from numerous centers across North America, including practices performing more limited patch testing, would provide a broader perspective of contact allergen prevalence in North America. The American Contact Dermatitis Society Contact Allergy Management Program is an ideal tool for collection of epidemiologic data regarding contact allergy prevalence in North America. The aim of the study was to identify the relative prevalence of contact allergy to common contact allergens in North America. Mapping of Contact Allergy Management Program (CAMP) data was performed to allow analysis of how frequently searches were performed for various contact allergens. The number of searches performed for specific allergens provides a measure of the relative prevalence of contact allergy to these allergens. The top 35 allergens for the period from November 18, 2012 to November 18, 2013 are reported. Although these data are useful, specific recommendations for minor alterations to CAMP are discussed, which will allow future CAMP data to be stratified and more powerful. With minor modifications, CAMP can provide a quantum leap in the reporting of contact allergy epidemiologic data in North America.
The Value Range of Contact Stiffness Factor between Pile and Soil Based on Penalty Function
Chen, Sandy H. L.; Wu, Xinliu
2018-03-01
The value range of contact stiffness factor based on penalty function is studied when we use finite element software ANSYS to analyze contact problems, take single pile and soil of a certain project for example, the normal contact between pile and soil is analyzed with 2D simplified model in horizontal load. The study shows that when adopting linear elastic model to simulate soil, the maximum contact pressure and penetration approach steady value as the contact stiffness factor increases. The reasonable value range of contact stiffness factor reduces as the underlying element thickness decreases, but the rule reverses when refers to the soil stiffness. If choose DP model to simulate soil, the stiffness factor should be magnified 100 times compares to the elastic model regardless of the soil bears small force and still in elastic deformation stage or into the plastic deformation stage. When the soil bears big force and into plastic deformation stage, the value range of stiffness factor relates to the plastic strain range of the soil, and reduces as the horizontal load increases.
A Numerical Simulation of Elastoplastic Contact Analysis of Compressor by Overspeeding
Directory of Open Access Journals (Sweden)
Aihua Liao
2014-04-01
Full Text Available This study analyzes the stress distribution of 3D elastoplastic contact problems by using the FE parametric quadratic programming (PQP method derived from a 3D FE model based on parametric variational principle (PVP. We numerically analyze a 24-blade compressor by combining centrifugal loading with interference-fit one. To accelerate computation, calculation is simplified by structural modeling via multisubstructuring, aiming to deal with FE-simulated computer aided design (CAD conveniently. We then analyze the relationships between the maximum residual stresses of the compressor posterior to prestressing and overspeed rpms, and we also study the distribution and magnitude of the contact stresses of the compressor in working conditions after overspeed prestressing. Moreover, we thoroughly discuss the distribution and magnitude of the contact stresses of shaft-shaft sleeve-impeller in working conditions. Relative displacement can be prevented and contact stress can be kept uniform due to the nonuniform initial amount of interference in overspeed prestressing. This paper summarizes the FEM simulation results and provides reference data for improving the design and processing of compressor impellers, indicating that overspeed is indispensable in manufacture.
Alternative current source based Schottky contact with additional electric field
Mamedov, R. K.; Aslanova, A. R.
2017-07-01
Additional electric field (AEF) in the Schottky contacts (SC) that covered the peripheral contact region wide and the complete contact region narrow (as TMBS diode) SC. Under the influence of AEF is a redistribution of free electrons produced at certain temperatures of the semiconductor, and is formed the space charge region (SCR). As a result of the superposition of the electric fields SCR and AEF occurs the resulting electric field (REF). The REF is distributed along a straight line perpendicular to the contact surface, so that its intensity (and potential) has a minimum value on the metal surface and the maximum value at a great distance from the metal surface deep into the SCR. Under the influence of AEF as a sided force the metal becomes negative pole and semiconductor - positive pole, therefore, SC with AEF becomes an alternative current source (ACS). The Ni-nSi SC with different diameters (20-1000 μm) under the influence of the AEF as sided force have become ACS with electromotive force in the order of 0.1-1.0 mV, which are generated the electric current in the range of 10-9-10-7 A, flowing through the external resistance 1000 Ohm.
Chen, Sun-Zen; Peng, Shiang-Hau; Ting, Tzu-Yu; Wu, Po-Shien; Lin, Chun-Hao; Chang, Chin-Yeh; Shyue, Jing-Jong; Jou, Jwo-Huei
2012-10-01
We demonstrate the feasibility of using direct contact-printing in the fabrication of monochromatic and polychromatic organic light-emitting diodes (OLEDs). Bright devices with red, green, blue, and white contact-printed light-emitting layers with a respective maximum luminance of 29 000, 29 000, 4000, and 18 000 cd/m2 were obtained with sound film integrity by blending a polymeric host into a molecular host. For the red OLED as example, the maximum luminance was decreased from 29 000 to 5000 cd/m2 as only the polymeric host was used, or decreased to 7000 cd/m2 as only the molecular host was used. The markedly improved device performance achieved in the devices with blended hosts may be attributed to the employed polymeric host that contributed a good film-forming character, and the molecular host that contributed a good electroluminescence character.
Approximate maximum parsimony and ancestral maximum likelihood.
Alon, Noga; Chor, Benny; Pardi, Fabio; Rapoport, Anat
2010-01-01
We explore the maximum parsimony (MP) and ancestral maximum likelihood (AML) criteria in phylogenetic tree reconstruction. Both problems are NP-hard, so we seek approximate solutions. We formulate the two problems as Steiner tree problems under appropriate distances. The gist of our approach is the succinct characterization of Steiner trees for a small number of leaves for the two distances. This enables the use of known Steiner tree approximation algorithms. The approach leads to a 16/9 approximation ratio for AML and asymptotically to a 1.55 approximation ratio for MP.
Nelde, Peter Hans
1995-01-01
Examines the phenomenon of language contact and recent trends in linguistic contact research, which focuses on language use, language users, and language spheres. Also discusses the role of linguistic and cultural conflicts in language contact situations. (13 references) (MDM)
Characteristics of Plantar Loads in Maximum Forward Lunge Tasks in Badminton.
Hu, Xiaoyue; Li, Jing Xian; Hong, Youlian; Wang, Lin
2015-01-01
Badminton players often perform powerful and long-distance lunges during such competitive matches. The objective of this study is to compare the plantar loads of three one-step maximum forward lunges in badminton. Fifteen right-handed male badminton players participated in the study. Each participant performed five successful maximum lunges at three directions. For each direction, the participant wore three different shoe brands. Plantar loading, including peak pressure, maximum force, and contact area, was measured by using an insole pressure measurement system. Two-way ANOVA with repeated measures was employed to determine the effects of the different lunge directions and different shoes, as well as the interaction of these two variables, on the measurements. The maximum force (MF) on the lateral midfoot was lower when performing left-forward lunges than when performing front-forward lunges (p = 0.006, 95% CI = -2.88 to -0.04%BW). The MF and peak pressures (PP) on the great toe region were lower for the front-forward lunge than for the right-forward lunge (MF, p = 0.047, 95% CI = -3.62 to -0.02%BW; PP, p = 0.048, 95% CI = -37.63 to -0.16 KPa) and left-forward lunge (MF, p = 0.015, 95% CI = -4.39 to -0.38%BW; PP, p = 0.008, 95% CI = -47.76 to -5.91 KPa). These findings indicate that compared with the front-forward lunge, left and right maximum forward lunges induce greater plantar loads on the great toe region of the dominant leg of badminton players. The differences in the plantar loads of the different lunge directions may be potential risks for injuries to the lower extremities of badminton players.
Simulated epidemics in an empirical spatiotemporal network of 50,185 sexual contacts.
Directory of Open Access Journals (Sweden)
Luis E C Rocha
2011-03-01
Full Text Available Sexual contact patterns, both in their temporal and network structure, can influence the spread of sexually transmitted infections (STI. Most previous literature has focused on effects of network topology; few studies have addressed the role of temporal structure. We simulate disease spread using SI and SIR models on an empirical temporal network of sexual contacts in high-end prostitution. We compare these results with several other approaches, including randomization of the data, classic mean-field approaches, and static network simulations. We observe that epidemic dynamics in this contact structure have well-defined, rather high epidemic thresholds. Temporal effects create a broad distribution of outbreak sizes, even if the per-contact transmission probability is taken to its hypothetical maximum of 100%. In general, we conclude that the temporal correlations of our network accelerate outbreaks, especially in the early phase of the epidemics, while the network topology (apart from the contact-rate distribution slows them down. We find that the temporal correlations of sexual contacts can significantly change simulated outbreaks in a large empirical sexual network. Thus, temporal structures are needed alongside network topology to fully understand the spread of STIs. On a side note, our simulations further suggest that the specific type of commercial sex we investigate is not a reservoir of major importance for HIV.
Directory of Open Access Journals (Sweden)
Xiao Guo
2017-10-01
Full Text Available Electrostatic properties of asymmetrically contacted carbon nanotube barrier-free bipolar diode photodetector are studied by solving the Poisson equation self-consistently with equilibrium carrier statistics. For electric field parallel to tube’s axis, the maximum electric field occurs near contact but decays rapidly in a few nanometers, followed by a slowly increasing trend when it extends to the center of channel. By considering the field ionization and the diffusion effect of exciton, a model of estimation on quantum efficiency for the device is made. We find that the quantum efficiency increases with increasing exciton lifetime, decreasing diffusion constant and channel length. For devices with a channel length shorter than 50 nm, the contribution of field ionization to the quantum efficiency can reach 60%.
Evaluation of anti-tuberculosis antibodies in healthy contact and non-contacts persons
International Nuclear Information System (INIS)
Aziz, N; Bukhari, M.H; Muneer, M; Tayyab, M; Chaudhry, N.A.
2006-01-01
This study was conducted to see the presence of the antimycobacterial antibodies in healthy household contacts of tuberculosis patients and healthy normal subjects who have never been in contact with tuberculosis patients. A total of 200 subjects, 120 with history of household contact and 80 without such history were included in the study. Routine Haematological investigations were performed and all the sera of 200 subjects were tested who 19M, 19G and IgA anti tuberculosis antibodies using ELISA technique. There was no difference in the average age of the household contacts and non-contacts. The complaints of pyrexia, night sweats and loss of weight was more in house hold contacts as compared to non-contacts. The awareness about BCG vaccination was equal among the household contacts and non-contacts. The combined serological positivity of the household contacts was 65.8% and the combined serological positivity for non-contacts was 34.1%. There was no statistically significant difference in the presence of 19M among household contacts as compared to non-contacts. However both IgG and 19A were present in significantly higher number of household contacts as compared to non contacts. This study concludes that the persons living in the house with a patient suffering from active pulmonary tuberculosis (household contact) have more chances of being infected with Mycobacterium tuberculosis as compared to the healthy non-contacts. (author)
Effect of skin hydration on the dynamics of fingertip gripping contact.
André, T; Lévesque, V; Hayward, V; Lefèvre, P; Thonnard, J-L
2011-11-07
The dynamics of fingertip contact manifest themselves in the complex skin movements observed during the transition from a stuck state to a fully developed slip. While investigating this transition, we found that it depended on skin hydration. To quantify this dependency, we asked subjects to slide their index fingertip on a glass surface while keeping the normal component of the interaction force constant with the help of visual feedback. Skin deformation inside the contact region was imaged with an optical apparatus that allowed us to quantify the relative sizes of the slipping and sticking regions. The ratio of the stuck skin area to the total contact area decreased linearly from 1 to 0 when the tangential force component increased from 0 to a maximum. The slope of this relationship was inversely correlated to the normal force component. The skin hydration level dramatically affected the dynamics of the contact encapsulated in the course of evolution from sticking to slipping. The specific effect was to reduce the tendency of a contact to slip, regardless of the variations of the coefficient of friction. Since grips were more unstable under dry skin conditions, our results suggest that the nervous system responds to dry skin by exaggerated grip forces that cannot be simply explained by a change in the coefficient of friction.
International Nuclear Information System (INIS)
He Jun; Guo Yongjin; Lin Zhongqin
2008-01-01
The theoretical equation of thermosonic bond strength involving interfacial deformation and microcontact phenomena is presented in this study. The constitutive equation of gold considering the ultrasonic softening mechanism was developed based on the thermosonic bonding experiments and coded into the FE software. The numerical model of bonding was established to estimate the surface exposure and the effective normal pressure. The real contact area was calculated by a microcontact model. Accordingly, the nominal bond strength can be obtained and verified by the experimental data. It is found that a better conjunction exists at the edge of the contact area because large surface exposure is produced there, which is also proved by the SEM image of a sheared ball bond. Increasing the bonding force or the ultrasonic power will increase the interfacial plastic deformation, the nominal and real contact areas, but decreases the effective normal pressure. The contact ratio increases to a maximum with the increase in the bonding force, and then decreases while it continues to decrease with the increase in the ultrasonic power. In addition, both the stress analysis and experimental result show that cratering and damage to the pad structure are easily produced below the edge region of the contact area under an excessive bonding force or ultrasonic power
Utanohara, Yuri; Hayashi, Ryo; Yoshikawa, Mineka; Yoshida, Mitsuyoshi; Tsuga, Kazuhiro; Akagawa, Yasumasa
2008-09-01
It is clinically important to evaluate tongue function in terms of rehabilitation of swallowing and eating ability. We have developed a disposable tongue pressure measurement device designed for clinical use. In this study we used this device to determine standard values of maximum tongue pressure in adult Japanese. Eight hundred fifty-three subjects (408 male, 445 female; 20-79 years) were selected for this study. All participants had no history of dysphagia and maintained occlusal contact in the premolar and molar regions with their own teeth. A balloon-type disposable oral probe was used to measure tongue pressure by asking subjects to compress it onto the palate for 7 s with maximum voluntary effort. Values were recorded three times for each subject, and the mean values were defined as maximum tongue pressure. Although maximum tongue pressure was higher for males than for females in the 20-49-year age groups, there was no significant difference between males and females in the 50-79-year age groups. The maximum tongue pressure of the seventies age group was significantly lower than that of the twenties to fifties age groups. It may be concluded that maximum tongue pressures were reduced with primary aging. Males may become weaker with age at a faster rate than females; however, further decreases in strength were in parallel for male and female subjects.
... Consumers Consumer Information by Audience For Women Contact Lens Care Share Tweet Linkedin Pin it More sharing ... www.fda.gov/medwatch Learn More about Contact Lens Care Other Tips on Contact Lenses Decorative Contact ...
Prediction of static friction coefficient in rough contacts based on the junction growth theory
Spinu, S.; Cerlinca, D.
2017-08-01
The classic approach to the slip-stick contact is based on the framework advanced by Mindlin, in which localized slip occurs on the contact area when the local shear traction exceeds the product between the local pressure and the static friction coefficient. This assumption may be too conservative in the case of high tractions arising at the asperities tips in the contact of rough surfaces, because the shear traction may be allowed to exceed the shear strength of the softer material. Consequently, the classic frictional contact model is modified in this paper so that gross sliding occurs when the junctions formed between all contacting asperities are independently sheared. In this framework, when the contact tractions, normal and shear, exceed the hardness of the softer material on the entire contact area, the material of the asperities yields and the junction growth process ends in all contact regions, leading to gross sliding inception. This friction mechanism is implemented in a previously proposed numerical model for the Cattaneo-Mindlin slip-stick contact problem, which is modified to accommodate the junction growth theory. The frictionless normal contact problem is solved first, then the tangential force is gradually increased, until gross sliding inception. The contact problems in the normal and in the tangential direction are successively solved, until one is stabilized in relation to the other. The maximum tangential force leading to a non-vanishing stick area is the static friction force that can be sustained by the rough contact. The static friction coefficient is eventually derived as the ratio between the latter friction force and the normal force.
Apparent contact angle and contact angle hysteresis on liquid infused surfaces.
Semprebon, Ciro; McHale, Glen; Kusumaatmaja, Halim
2016-12-21
We theoretically investigate the apparent contact angle and contact angle hysteresis of a droplet placed on a liquid infused surface. We show that the apparent contact angle is not uniquely defined by material parameters, but also has a dependence on the relative size between the droplet and its surrounding wetting ridge formed by the infusing liquid. We derive a closed form expression for the contact angle in the limit of vanishing wetting ridge, and compute the correction for small but finite ridge, which corresponds to an effective line tension term. We also predict contact angle hysteresis on liquid infused surfaces generated by the pinning of the contact lines by the surface corrugations. Our analytical expressions for both the apparent contact angle and contact angle hysteresis can be interpreted as 'weighted sums' between the contact angles of the infusing liquid relative to the droplet and surrounding gas phases, where the weighting coefficients are given by ratios of the fluid surface tensions.
Evaluation of metal–nanowire electrical contacts by measuring contact end resistance
International Nuclear Information System (INIS)
Park, Hongsik; Beresford, Roderic; Xu, Jimmy; Ha, Ryong; Choi, Heon-Jin; Shin, Hyunjung
2012-01-01
It is known, but often unappreciated, that the performance of nanowire (NW)-based electrical devices can be significantly affected by electrical contacts between electrodes and NWs, sometimes to the extent that it is really the contacts that determine the performance. To correctly understand and design NW device operation, it is thus important to carefully measure the contact resistance and evaluate the contact parameters, specific contact resistance and transfer length. A four-terminal pattern or a transmission line model (TLM) pattern has been widely used to measure contact resistance of NW devices and the TLM has been typically used to extract contact parameters of NW devices. However, the conventional method assumes that the electrical properties of semiconducting NW regions covered by a metal are not changed after electrode formation. In this study, we report that the conventional methods for contact evaluation can give rise to considerable errors because of an altered property of the NW under the electrodes. We demonstrate that more correct contact resistance can be measured from the TLM pattern rather than the four-terminal pattern and correct contact parameters including the effects of changed NW properties under electrodes can be evaluated by using the contact end resistance measurement method. (paper)
Rolling Contact Fatigue Failure Mechanisms of Plasma-Nitrided Ductile Cast Iron
Wollmann, D.; Soares, G. P. P. P.; Grabarski, M. I.; Weigert, N. B.; Escobar, J. A.; Pintaude, G.; Neves, J. C. K.
2017-05-01
Rolling contact fatigue (RCF) of a nitrided ductile cast iron was investigated. Flat washers machined from a pearlitic ductile cast iron bar were quenched and tempered to maximum hardness, ground, polished and divided into four groups: (1) specimens tested as quenched and tempered; (2) specimens plasma-nitrided for 8 h at 400 °C; (3) specimens plasma-nitrided and submitted to a diffusion process for 16 h at 400 °C; and (4) specimens submitted to a second tempering for 24 h at 400 °C. Hardness profiles, phase analyses and residual stress measurements by x-ray diffraction, surface roughness and scanning electron microscopy were applied to characterize the surfaces at each step of this work. Ball-on-flat washer tests were conducted with a maximum contact pressure of 3.6 GPa, under flood lubrication with a SAE 90 API GL-5 oil at 50 °C. Test ending criterion was the occurrence of a spalling. Weibull analysis was used to characterize RCF's lifetime data. Plasma-nitrided specimens exhibited a shorter RCF lifetime than those just quenched and tempered. The effects of nitriding on the mechanical properties and microstructure of the ductile cast iron are discussed in order to explain the shorter endurance of nitrided samples.
Contextualizing Intergroup Contact: Do Political Party Cues Enhance Contact Effects?
DEFF Research Database (Denmark)
Sønderskov, Kim Mannemar; Thomsen, Jens Peter Frølund
2015-01-01
This article examines intergroup contact effects in different political contexts. We expand on previous efforts of social psychologists by incorporating the messages of political parties as a contextual trigger of group membership awareness in contact situations. We argue that the focus among...... political parties on us-them categorizations heightens the awareness of group memberships. This focus in turn enhances the positive intergroup contact effect by stimulating majority members to perceive contacted persons as prototypical outgroup members. A multilevel analysis of 22 countries and almost 37......,000 individuals confirms that the ability of intergroup contact to reduce antiforeigner sentiment increases when political parties focus intensively on immigration issues and cultural differences. Specifically, both workplace contact and interethnic friendship become more effective in reducing antiforeigner...
Measuring contact area in a sliding human finger-pad contact.
Liu, X; Carré, M J; Zhang, Q; Lu, Z; Matcher, S J; Lewis, R
2018-02-01
The work outlined in this paper was aimed at achieving further understanding of skin frictional behaviour by investigating the contact area between human finger-pads and flat surfaces. Both the static and the dynamic contact areas (in macro- and micro-scales) were measured using various techniques, including ink printing, optical coherence tomography (OCT) and Digital Image Correlation (DIC). In the studies of the static measurements using ink printing, the experimental results showed that the apparent and the real contact area increased with load following a piecewise linear correlation function for a finger-pad in contact with paper sheets. Comparisons indicated that the OCT method is a reliable and effective method to investigate the real contact area of a finger-pad and allow micro-scale analysis. The apparent contact area (from the DIC measurements) was found to reduce with time in the transition from the static phase to the dynamic phase while the real area of contact (from OCT) increased. The results from this study enable the interaction between finger-pads and contact object surface to be better analysed, and hence improve the understanding of skin friction. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Characteristics of Plantar Loads in Maximum Forward Lunge Tasks in Badminton.
Directory of Open Access Journals (Sweden)
Xiaoyue Hu
Full Text Available Badminton players often perform powerful and long-distance lunges during such competitive matches. The objective of this study is to compare the plantar loads of three one-step maximum forward lunges in badminton.Fifteen right-handed male badminton players participated in the study. Each participant performed five successful maximum lunges at three directions. For each direction, the participant wore three different shoe brands. Plantar loading, including peak pressure, maximum force, and contact area, was measured by using an insole pressure measurement system. Two-way ANOVA with repeated measures was employed to determine the effects of the different lunge directions and different shoes, as well as the interaction of these two variables, on the measurements.The maximum force (MF on the lateral midfoot was lower when performing left-forward lunges than when performing front-forward lunges (p = 0.006, 95% CI = -2.88 to -0.04%BW. The MF and peak pressures (PP on the great toe region were lower for the front-forward lunge than for the right-forward lunge (MF, p = 0.047, 95% CI = -3.62 to -0.02%BW; PP, p = 0.048, 95% CI = -37.63 to -0.16 KPa and left-forward lunge (MF, p = 0.015, 95% CI = -4.39 to -0.38%BW; PP, p = 0.008, 95% CI = -47.76 to -5.91 KPa.These findings indicate that compared with the front-forward lunge, left and right maximum forward lunges induce greater plantar loads on the great toe region of the dominant leg of badminton players. The differences in the plantar loads of the different lunge directions may be potential risks for injuries to the lower extremities of badminton players.
International Nuclear Information System (INIS)
Cuthrell, R.E.
1976-01-01
Electrical contacts must function properly in many types of components used in nuclear weapon systems. Design, application, and testing of these components require detailed knowledge of chemical and physical phenomena associated with stockpile storage, stockpile testing, and operation. In the past, investigation of these phenomena has led to significant discoveries on the effects of surface contaminants, friction and wear, and the mechanics of closure on contact performance. A recent investigation of contact arcing phenomena which revealed that, preceding contact closure, arcs may occur at voltages lower than had been previously known is described. This discovery is important, since arcing may damage contacts, and repetitive testing of contacts performed as part of a quality assurance program might produce cumulative damage that would yield misleading life-test data and could prevent proper operation of the contacts at some time in the future. This damage can be avoided by determining the conditions under which arcing occurs, and ensuring that these conditions are avoided in contact testing
Plate-shaped non-contact ultrasonic transporter using flexural vibration.
Ishii, Takahiko; Mizuno, Yosuke; Koyama, Daisuke; Nakamura, Kentaro; Harada, Kana; Uchida, Yukiyoshi
2014-02-01
We developed a plate-shaped non-contact transporter based on ultrasonic vibration, exploiting a phenomenon that a plate can be statically levitated at the place where its gravity and the acoustic radiation force are balanced. In the experiment, four piezoelectric zirconate titanate elements were attached to aluminum plates, on which lattice flexural vibration was excited at 22.3 kHz. The vibrating plates were connected to a loading plate via flexible posts that can minimize the influence of the flexure induced by heavy loads. The distribution of the vibration displacement on the plate was predicted through finite-element analysis to find the appropriate positions of the posts. The maximum levitation height of this transporter was 256 μm with no load. When two vibrating plates were connected to a loading plate, the maximum transportable load was 4.0 kgf. Copyright © 2013. Published by Elsevier B.V.
Current voltage characteristics of composite superconductors with high contact resistance
International Nuclear Information System (INIS)
Akhmetov, A.A.; Baev, V.P.
1984-01-01
An experimental study has been made of current-voltage characteristics of composite superconductors with contact resistance between superconducting filaments and normal metal with high electrical conductivity. It is shown that stable resistive states exist in such conductors over a wide range of currents. The presence of resistive states is interpreted in terms of the resistive domain concept. The minimum and maximum currents of resistive states are found to be dependent on the electrical resistance of normal metal and magnetic field. (author)
Troeltzsch, M; Troeltzsch, M; Cronin, R J; Brodine, A H; Frankenberger, R; Messlinger, K
2011-06-01
Although an interaction of malocclusion, parafunction, and temporomandibular joint disorders (TMD) can be inferred from the experience of daily practice, scientific evidence to corroborate this hypothesis does not exist. However, there are indications that TMD and headaches may be intertwined. The purpose of this study was to identify the presence or absence of an association of occlusal interferences, parafunction, TMD, or physiologic, muscular, or prosthodontic factors with the occurrence of headache. In a private practice population of 1031 subjects (436 men and 595 women, mean age 49.6 years) the demographic parameters, headache and general pain history, habits and general personal information were recorded. Clinical examination for dental, muscular, and temporomandibular joint pathology was accomplished. Data were statistically analyzed using the Mann-Whitney U, Kruskal-Wallis, and Chi-Square tests (α = .05). A multinomial logistic regression analysis was performed with respect to confounding variables. Headache affliction was found to affect women more frequently than men (1.7:1). Students and non academics were more prone to suffer from headache. Parafunction (P=.001), TMD (P=.001) and gross differences between centric occlusion and maximum intercuspation of more than a 3 mm visible track marked with 8 μm articulation foil (P=.001) significantly influenced the presence of headache. Headache intensity and frequency decreased with age. While tension-type headache was most frequently diagnosed, the parameters studied were not significantly associated with one certain headache diagnosis more frequently than others. Stomatognathic factors of TMD, parafunction, and gross differences between centric occlusion and maximum intercuspation of more than 3 mm are associated with headache. These findings should be interpreted with caution due to the cross-sectional nature of this study. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry
International Nuclear Information System (INIS)
Siswanto, W. A.; Nagentrau, M.; Tobi, A. L. Mohd; Tamin, M. N.
2016-01-01
We compared the quasi-static and dynamic simulation responses on elastic-plastic deformation of advanced alloys using Finite element (FE) method with an explicit numerical algorithm. A geometrical model consisting of a cylinder-on-flat surface contact under a normal load and sliding motion was examined. Two aeroengine materials, Ti-6Al-4V and Super CMV (Cr-Mo-V) alloy, were employed in the FE analysis. The FE model was validated by comparative magnitudes of the FE-predicted maximum contact pressure variation along the contact half-width length with the theoretical Hertzian contact solution. Results show that the (compressive) displacement of the initial contact surface steadily increases for the quasi-static load case, but accumulates at an increasing rate to the maximum level for the dynamic loading. However, the relatively higher stiffness and yield strength of the Super CMV alloy resulted in limited deformation and low plastic strain when compared to the Ti-6Al-4V alloy. The accumulated equivalent plastic strain of the material point at the initial contact position was nearly a thousand times higher for the dynamic load case (for example, 6.592 for Ti-6Al-4V, 1.0 kN) when compared to the quasi-static loading (only 0.0072). During the loading step, the von Mises stress increased with a decreasing and increasing rate for the quasi-static and dynamic load case, respectively. A sudden increase in the stress magnitude to the respective peak value was registered due to the additional constraint to overcome the static friction of the mating surfaces during the sliding step
Energy Technology Data Exchange (ETDEWEB)
Siswanto, W. A.; Nagentrau, M.; Tobi, A. L. Mohd [Faculty of Mechanical and Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, Batu Pahat (Malaysia); Tamin, M. N. [Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, Johor Bahru (Malaysia)
2016-11-15
We compared the quasi-static and dynamic simulation responses on elastic-plastic deformation of advanced alloys using Finite element (FE) method with an explicit numerical algorithm. A geometrical model consisting of a cylinder-on-flat surface contact under a normal load and sliding motion was examined. Two aeroengine materials, Ti-6Al-4V and Super CMV (Cr-Mo-V) alloy, were employed in the FE analysis. The FE model was validated by comparative magnitudes of the FE-predicted maximum contact pressure variation along the contact half-width length with the theoretical Hertzian contact solution. Results show that the (compressive) displacement of the initial contact surface steadily increases for the quasi-static load case, but accumulates at an increasing rate to the maximum level for the dynamic loading. However, the relatively higher stiffness and yield strength of the Super CMV alloy resulted in limited deformation and low plastic strain when compared to the Ti-6Al-4V alloy. The accumulated equivalent plastic strain of the material point at the initial contact position was nearly a thousand times higher for the dynamic load case (for example, 6.592 for Ti-6Al-4V, 1.0 kN) when compared to the quasi-static loading (only 0.0072). During the loading step, the von Mises stress increased with a decreasing and increasing rate for the quasi-static and dynamic load case, respectively. A sudden increase in the stress magnitude to the respective peak value was registered due to the additional constraint to overcome the static friction of the mating surfaces during the sliding step.
Influence of occlusal contact area on cusp defection and stress distribution.
Costa, Anna Karina Figueiredo; Xavier, Thaty Aparecida; Paes-Junior, Tarcisio José Arruda; Andreatta-Filho, Oswaldo Daniel; Borges, Alexandre Luiz Souto
2014-11-01
The purpose of this study was to evaluate the effect of occlusal contact area for loading on the cuspal defection and stress distribution in a first premolar restored with a high elastic modulus restorative material. The Rhinoceros 4.0 software was used for modeling the three-dimensional geometries of dental and periodontal structures and the inlay restoration. Thus, two different models, intact and restored teeth with three occlusal contact areas, 0.1, 0.5 and 0.75 mm(2), on enamel at the occlusal surface of buccal and lingual cusps. Finite element analysis (FEA) was performed with the program ANSYS (Workbench 13.0), which generated a mesh with tetrahedral elements with greater refinement in the regions of interest, and was constrained at the bases of cortical and trabecular bone in all axis and loaded with 100 N normal to each contact area. To analysis of maximum principal stress, the smaller occlusal contact area showed greater compressive stress in region of load application for both the intact and inlay restored tooth. However, tensile stresses at the occlusal isthmus were similar for all three tested occlusal contact areas (60 MPa). To displacement of the cusps was higher for teeth with inlay (0.46-0.48 mm). For intact teeth, the smaller contact area showed greater displacement (0.10 mm). For teeth with inlays, the displacement of the cusps were similar in all types of occlusal area. Cuspal displacement was higher in the restored tooth when compared to the intact tooth, but there were no significant variations even with changes in the occlusal contact area. RELEVANCE CLINICAL: Occlusal contacts have a great influence on the positioning of teeth being able to maintain the position and stability of the mandible. Axial loads would be able to generate more uniform stress at the root presenting a greater concentration of load application in the point and the occlusal surface. Thus, is necessary to analyze the relationship between these occlusal contacts as dental
Effect of thermal contact resistances on fast charging of large format lithium ion batteries
International Nuclear Information System (INIS)
Ye, Yonghuang; Saw, Lip Huat; Shi, Yixiang; Somasundaram, Karthik; Tay, Andrew A.O.
2014-01-01
Highlights: • The effect of thermal contact resistance on thermal performance of large format lithium ion batteries. • The effect of temperature gradient on electrochemical performance of large format batteries during fast charging. • The thermal performance of lithium ion battery utilizing pulse charging protocol. • Suggestions on battery geometry design optimization to improve thermal performance. - Abstract: A two dimensional electrochemical thermal model is developed on the cross-plane of a laminate stack plate pouch lithium ion battery to study the thermal performance of large format batteries. The effect of thermal contact resistance is taken into consideration, and is found to greatly increase the maximum temperature and temperature gradient of the battery. The resulting large temperature gradient would induce in-cell non-uniformity of charging-discharging current and state of health. Simply increasing the cooling intensity is inadequate to reduce the maximum temperature and narrow down the temperature difference due to the poor cross-plane thermal conductivity. Pulse charging protocol does not help to mitigate the temperature difference on the bias of same total charging time, because of larger time-averaged heat generation rate than constant current charging. Suggestions on battery geometry optimizations for both prismatic/pouch battery and cylindrical battery are proposed to reduce the maximum temperature and mitigate the temperature gradient within the lithium ion battery
Yu, Ying-Song; Xia, Xue-Lian; Zheng, Xu; Huang, Xianfu; Zhou, Jin-Zhi
2017-09-01
In this paper, evaporation of sessile water droplets containing fluorescent polystyrene (PS) microparticles on polydimethylsiloxane (PDMS) surfaces with different curing ratios was studied experimentally using laser confocal microscopy. At the beginning, there were some microparticles located at the contact line and some microparticles moved towards the line. Due to contact angle hysteresis, at first both the contact line and the microparticles were pinned. With the depinning contact line, the microparticles moved together spontaneously. Using the software ImageJ, the location of contact lines at different time were acquired and the circle centers and radii of the contact lines were obtained via the least square method. Then the average distance of two neighbor contact lines at a certain time interval was obtained to characterize the motion of the contact line. Fitting the distance-time curve at the depinning contact line stage with polynomials and differentiating the polynomials with time, we obtained the velocity and acceleration of both the contact line and the microparticles located at the line. The velocity and the maximum acceleration were, respectively, of the orders of 1 μm/s and 20-200 nm/s2, indicating that the motion of the microparticles located at the depinning contact line was quasi-static. Finally, we presented a theoretical model to describe the quasi-static process, which may help in understanding both self-pinning and depinning of microparticles.
International Nuclear Information System (INIS)
Anon.
1979-01-01
This chapter presents a historic overview of the establishment of radiation guidelines by various national and international agencies. The use of maximum permissible dose and maximum permissible body burden limits to derive working standards is discussed
Directory of Open Access Journals (Sweden)
Meltem Önder
2009-03-01
Full Text Available Allergic contact dermatitis is the delayed type hypersensitivity reaction to exogenous agents. Allergic contact dermatitis may clinically present acutely after allergen exposure and initial sensitization in a previously sensitized individual. Acute phase is characterized by erythematous, scaly plaques. In severe cases vesiculation and bullae in exposed areas are very characteristic. Repeated or continuous exposure of sensitized individual with allergen result in chronic dermatitis. Lichenification, erythematous plaques, hyperkeratosis and fissuring may develop in chronic patients. Allergic contact dermatitis is very common dermatologic problem in dermatology daily practice. A diagnosis of contact dermatitis requires the careful consideration of patient history, physical examination and patch testing. The knowledge of the clinical features of the skin reactions to various contactans is important to make a correct diagnosis of contact dermatitis. It can be seen in every age, in children textile product, accessories and touch products are common allergens, while in adults allergic contact dermatitis may be related with topical medicaments. The contact pattern of contact dermatitis depends on fashion and local traditions as well. The localization of allergic reaction should be evaluated and patients’ occupation and hobbies should be asked. The purpose of this review is to introduce to our collaques up dated allergic contact dermatitis literatures both in Turkey and in the World.
Determination of the mass-transfer coefficient in liquid phase in a stream-bubble contact device
Dmitriev, A. V.; Dmitrieva, O. S.; Madyshev, I. N.
2016-09-01
One of the most effective energy saving technologies is the improvement of existing heat and mass exchange units. A stream-bubble contact device is designed to enhance the operation efficiency of heat and mass exchange units. The stages of the stream-bubble units that are proposed by the authors for the decarbonization process comprise contact devices with equivalent sizes, whose number is determined by the required performance of a unit. This approach to the structural design eliminates the problems that arise upon the transition from laboratory samples to industrial facilities and makes it possible to design the units of any required performance without a decrease in the effectiveness of mass exchange. To choose the optimal design that provides the maximum effectiveness of the mass-exchange processes in units and their intensification, the change of the mass-transfer coefficient is analyzed with the assumption of a number of parameters. The results of the study of the effect of various structural parameters of a stream-bubble contact device on the mass-transfer coefficient in the liquid phase are given. It is proven that the mass-transfer coefficient increases in the liquid phase, in the first place, with the growth of the level of liquid in the contact element, because the rate of the liquid run-off grows in this case and, consequently, the time of surface renewal is reduced; in the second place, with an increase in the slot diameter in the downpipe, because the jet diameter and, accordingly, their section perimeter and the area of the surface that is immersed in liquid increase; and, in the third place, with an increase in the number of slots in the downpipe, because the area of the surface that is immersed in the liquid of the contact element increases. Thus, in order to increase the mass-transfer coefficient in the liquid phase, it is necessary to design the contact elements with a minimum width and a large number of slots and their increased diameter; in
Experimental investigation on the electrical contact behavior of rolling contact connector
Energy Technology Data Exchange (ETDEWEB)
Chen, Junxing; Yang, Fei, E-mail: yfei2007@mail.xjtu.edu.cn; Luo, Kaiyu; Zhu, Mingliang; Wu, Yi; Rong, Mingzhe [State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049 (China)
2015-12-15
Rolling contact connector (RCC) is a new technology utilized in high performance electric power transfer systems with one or more rotating interfaces, such as radars, satellites, wind generators, and medical computed tomography machines. Rolling contact components are used in the RCC instead of traditional sliding contacts to transfer electrical power and/or signal. Since the requirement of the power transmission is increasing in these years, the rolling electrical contact characteristics become more and more important for the long-life design of RCC. In this paper, a typical form of RCC is presented. A series of experimental work are carried out to investigate the rolling electrical contact characteristics during its lifetime. The influence of a variety of factors on the electrical contact degradation behavior of RCC is analyzed under both vacuum and air environment. Based on the surface morphology and elemental composition changes in the contact zone, which are assessed by field emission scanning electron microscope and confocal laser scanning microscope, the mechanism of rolling electrical contact degradation is discussed.
Stress-life relation of the rolling-contact fatigue spin rig
Butler, Robert H; Carter, Thomas L
1957-01-01
The rolling-contact fatigue spin rig was used to test groups of SAE 52100 9.16-inch-diameter balls lubricated with a mineral oil at 600,000-, 675,000-, and 750,000-psi maximum Hertz stress. Cylinders of AISI M-1 vacuum and commercial melts and MV-1 (AISI M-50) were used as race specimens. Stress-life exponents produced agree closely with values accepted in industry. The type of failure obtained in the spin rig was similar to the subsurface fatigue spells found in bearings.
Hypersensitivity to contact inhibition provides a clue to cancer resistance of naked mole-rat.
Seluanov, Andrei; Hine, Christopher; Azpurua, Jorge; Feigenson, Marina; Bozzella, Michael; Mao, Zhiyong; Catania, Kenneth C; Gorbunova, Vera
2009-11-17
The naked mole-rat is the longest living rodent with a maximum lifespan exceeding 28 years. In addition to its longevity, naked mole-rats have an extraordinary resistance to cancer as tumors have never been observed in these rodents. Furthermore, we show that a combination of activated Ras and SV40 LT fails to induce robust anchorage-independent growth in naked mole-rat cells, while it readily transforms mouse fibroblasts. The mechanisms responsible for the cancer resistance of naked mole-rats were unknown. Here we show that naked mole-rat fibroblasts display hypersensitivity to contact inhibition, a phenomenon we termed "early contact inhibition." Contact inhibition is a key anticancer mechanism that arrests cell division when cells reach a high density. In cell culture, naked mole-rat fibroblasts arrest at a much lower density than those from a mouse. We demonstrate that early contact inhibition requires the activity of p53 and pRb tumor suppressor pathways. Inactivation of both p53 and pRb attenuates early contact inhibition. Contact inhibition in human and mouse is triggered by the induction of p27(Kip1). In contrast, early contact inhibition in naked mole-rat is associated with the induction of p16(Ink4a). Furthermore, we show that the roles of p16(Ink4a) and p27(Kip1) in the control of contact inhibition became temporally separated in this species: the early contact inhibition is controlled by p16(Ink4a), and regular contact inhibition is controlled by p27(Kip1). We propose that the additional layer of protection conferred by two-tiered contact inhibition contributes to the remarkable tumor resistance of the naked mole-rat.
Directory of Open Access Journals (Sweden)
S. V. LOSKUTOV
2018-05-01
Full Text Available Purpose. To determine the contribution of the real contact spots distribution in the total conductivity of the conductors contact. Methodology. The electrical contact resistance research was carried out on models. The experimental part of this work was done on paper with a graphite layer with membranes (the first type and conductive liquids with discrete partitions (the second type. Findings. It is shown that the contact electrical resistance is mainly determined by the real area of metal contact. The experimental dependence of the electrical resistance of the second type model on the distance between the electrodes and the potential distribution along the sample surface for the first type model were obtained. The theoretical model based on the principle of electric field superposition was considered. The dependences obtained experimentally and calculated by using the theoretical model are in good agreement. Originality. The regularity of the electrical contact resistance formation on a large number of membranes was researched for the first time. A new model of discrete electrical contact based on the liquid as the conducting environment with nuclear membrane partitions was developed. The conclusions of the additivity of contact and bulk electrical resistance were done. Practical value. Based on these researches, a new experimental method of kinetic macroidentation that as a parameter of the metal surface layer deformation uses the real contact area was developed. This method allows to determine the value of average contact stresses, yield point, change of the stress on the depth of deformation depending on the surface treatment.
National audit of a system for rectal contact brachytherapy
Directory of Open Access Journals (Sweden)
Laia Humbert-Vidan
2017-01-01
Full Text Available Background and purpose: Contact brachytherapy is used for the treatment of early rectal cancer. An overview of the current status of quality assurance of the rectal contact brachytherapy systems in the UK, based on a national audit, was undertaken in order to assist users in optimising their own practices. Material and methods: Four UK centres using the Papillon 50 contact brachytherapy system were audited. Measurements included beam quality, output and radiation field size and uniformity. Test frequencies and tolerances were reviewed and compared to both existing recommendations and published reviews on other kV and electronic brachytherapy systems. External validation of dosimetric measurements was provided by the National Physical Laboratory. Results: The maximum host/audit discrepancy in beam quality determination was 6.5%; this resulted in absorbed dose variations of 0.2%. The host/audit agreement in absorbed dose determination was within 2.2%. The median of the radiation field uniformity measurements was 2.7% and the host/audit agreement in field size was within 1Â mm. Test tolerances and frequencies were within the national recommendations for kV units. Conclusions: The dosimetric characterisation of the Papillon 50 was validated by the audit measurements for all participating centres, thus providing reassurance that the implementation had been performed within the standards stated in previously published audit work and recommendations for kV and electronic brachytherapy units. However, optimised and standardised quality assurance testing could be achieved by reducing some methodological differences observed. Keywords: Contact brachytherapy, Electronic brachytherapy, Audit
Friction and universal contact area law for randomly rough viscoelastic contacts.
Scaraggi, M; Persson, B N J
2015-03-18
We present accurate numerical results for the friction force and the contact area for a viscoelastic solid (rubber) in sliding contact with hard, randomly rough substrates. The rough surfaces are self-affine fractal with roughness over several decades in length scales. We calculate the contribution to the friction from the pulsating deformations induced by the substrate asperities. We also calculate how the area of real contact, A(v, p), depends on the sliding speed v and on the nominal contact pressure p, and we show how the contact area for any sliding speed can be obtained from a universal master curve A(p). The numerical results are found to be in good agreement with the predictions of an analytical contact mechanics theory.
Current knowledge on biomarkers for contact sensitization and allergic contact dermatitis
DEFF Research Database (Denmark)
Koppes, Sjors A.; Engebretsen, Kristiane A.; Agner, Tove
2017-01-01
Contact sensitization is common and affects up to 20% of the general population. The clinical manifestation of contact sensitization is allergic contact dermatitis. This is a clinical expression that is sometimes difficult to distinguish from other types of dermatitis, for example irritant...... and atopic dermatitis. Several studies have examined the pathogenesis and severity of allergic contact dermatitis by measuring the absence or presence of various biomarkers. In this review, we provide a non-systematic overview of biomarkers that have been studied in allergic contact dermatitis. These include...... genetic variations and mutations, inflammatory mediators, alarmins, proteases, immunoproteomics, lipids, natural moisturizing factors, tight junctions, and antimicrobial peptides. We conclude that, despite the enormous amount of data, convincing specific biomarkers for allergic contact dermatitis are yet...
Coordinate transformation in the model of long Josephson contacts: geometrically equivalent contacts
International Nuclear Information System (INIS)
Semerdzhieva, E.G.; Boyadzhiev, T.L.; ); Shukrinov, Yu.M.; Physical Technical Institute Dushanbe, 734063
2005-01-01
The transition from model of long Josephson variable-width contact to the contact model with coordinate-dependent Josephson current amplitude is realized by transforming the coordinates. This sets up a correspondence between Josephson contacts of variable width and quasi-one-dimensional contacts of variable thickness barrier layer. It is shown, that for contacts of exponentially varying width the barrier layer of the corresponding quasi-one-dimensional contact contains the distributed resistive inhomogeneity which is an attractor to magnetic flux vortices. With numerical experiments, a 'critical current-magnetic field' dependence for a resistive microinhomogeneity Josephson contact was plotted, and its comparison with the critical curve for a contact of exponentially varying width was made. Thus, this demonstrates that the distributed inhomogeneity may be replaced by a local one at the JC end what technologically, may offer definite advantages
INFLUENCE OF MODIFIED BIOFLAVONOIDS UPON EFFECTOR LYMPHOCYTES IN MURINE MODEL OF CONTACT SENSITIVITY
Directory of Open Access Journals (Sweden)
D. Z. Albegova
2015-01-01
Full Text Available Contact sensitivity reaction (CSR to 2,4-dinitrofluorobenzene (DNFB in mice is a model of in vivo immune response, being an experimental analogue to contact dermatitis in humans. CSR sensitization phase begins after primary contact with antigen, lasting for 10-15 days in humans, and 5-7 days, in mice. Repeated skin exposure to the sensitizing substance leads to its recognition and triggering immune inflammatory mechanisms involving DNFB-specific effector T lymphocytes. The CSR reaches its maximum 18-48 hours after re-exposure to a hapten. There is only scarce information in the literature about effects of flavonoids on CSR, including both stimulatory and inhibitory effects. Flavonoids possessed, predominantly, suppressive effects against the CSR development. In our laboratory, a model of contact sensitivity was reproduced in CBA mice by means of cutaneous sensitization by 2,4-dinitrofluorobenzene. The aim of the study was to identify the mechanisms of immunomodulatory action of quercetin dihydrate and modified bioflavonoids, using the method of adoptive transfer contact sensitivity by splenocytes and T-lymphocytes. As shown in our studies, a 30-min pre-treatment of splenocytes and T-lymphocytes from sensitized mice with modified bioflavonoids before the cell transfer caused complete prevention of contact sensitivity reaction in syngeneic recipient mice. Meanwhile, this effect was not associated with cell death induction due to apoptosis or cytotoxicity. Quercetin dihydrate caused only partially suppression the activity of adaptively formed T-lymphocytes, the contact sensitivity effectors. It was shown that the modified bioflavonoid more stronger suppress adoptive transfer of contact sensitivity in comparison with quercetin dehydrate, without inducing apoptosis of effector cells. Thus, the modified bioflavonoid is a promising compound for further studies in a model of contact sensitivity, due to its higher ability to suppress transfer of CSR with
Hehne, H J; Riede, U N; Hauschild, G; Schlageter, M
1981-02-01
By means of section material, 24 partial and 58 subtotal meniscectomies were performed and the loss of tibio-femoral contact was evaluated by the Touchier-method planimetrically. In cases of partial resection this loss was 12% only, where as in subtotal resection 46%, where by the remaining contact zones lay in the central-, anyway meniscusfree area. The diagram of the chondral splitting lines showed a maximum of compression here, consecutively the remaining contact zone is reduced to the in earlier times most affected cartilage areas. The result correlates to the appearance of chondromalacies of the central tibial plateau in our own section cases and of postoperative osteoarthritis after subtotal meniscectomies in literature. Subtotal meniscectomies lead to incongruence and increased pressure. a pseudo-regeneration seems not to compensate the meniscus function sufficiently. A result for the clinic one should, when possible, resect menisci only partially.
First contact diagnosis and management of contact lens-related complications.
Fagan, Xavier J; Jhanji, Vishal; Constantinou, Marios; Amirul Islam, F M; Taylor, Hugh R; Vajpayee, Rasik B
2012-08-01
To describe the spectrum of contact lens-related problems in cases presenting to a tertiary referral eye hospital. A retrospective case record analysis of 111 eyes of 97 consecutive patients was undertaken over a period of five months at the Royal Victorian Eye and Ear Hospital, Melbourne, Australia. Contact lens-related complications (CLRC) were classified into microbial keratitis, sterile corneal infiltrates, corneal epitheliopathy and contact lens-related red eye (CLARE). Main parameters examined were nature of the first contact, clinical diagnosis, and management pattern. Forty-two percent of the initial presentations were to health care practitioners (HCPs) other than ophthalmologists. Mean duration from the onset of symptoms to presentation was 6.3 ± 10.9 days. Forty-nine percent (n = 54) of patients had an associated risk factor, most commonly overnight use of contact lenses (n = 14, 13 %). Most common diagnosis at presentation was corneal epitheliopathy (68 %) followed by sterile infiltrates (10 %), CLARE (8 %) and microbial keratitis (6 %). No significant differences were found in the pattern of treatment modalities administered by ophthalmologists and other HCPs. HCPs other than ophthalmologists are the first contact for contact lens-related problems in a significant proportion of patients. These HCPs manage the majority of CLRC by direct treatment or immediate referral.
Anton, Alexandra; Neuburger, Matthias; Böhringer, Daniel; Jordan, Jens F
2013-07-01
The aim of the present study was to compare the measurement of intraocular pressure (IOP) through a therapeutic soft contact lens with the "native" measurement. We additionally investigate whether a rebound tonometer (RT) or non-contact tonometer (NCT) is more suitable to measure IOP through a bandage contact lens. The IOP was determined using each of the two methods, three times successively with (lens measurement) and without (native measurement) a soft contact lens. The Icare tonometer (Icare® TA01i, Icare Finland Oy, 23 subjects) and the Airpuff tonometer (Nidek NT 53OP, Nidek CO., LTD, Hiroishi Gamagori, Aichi, Japan, 16 subjects) were used. We compared the mean values (validity parameter) and standard deviation (precision parameter) of the three individual measurements in each case using the paired t-test. In addition, we conducted a power analysis to estimate the maximum error in the measurement caused by the contact lens (power level set to 0.8). With the Airpuff tonometer we detected no statistically significant between the lens and the native measurement (15.6 ± 2.6 vs. 15.3 ± 2.6 mmHg; p = 0.42). The power analysis revealed that the maximum error caused by the contact lens was 1.2 mmHg. The Icare tonometry, however, trended toward higher values in the contact lens measurements (17.5 ± 4.3 vs. 16.4 ± 3.5 mmHg in the native measurements; p = 0.05). Interestingly, this difference exhibited a statistically significant correlation with the corneal thickness (0.03 mmHg per μm corneal thickness; p = 0.04). The use of NCT and RT for IOP measurement over a soft contact lens is feasible. The accuracy appears to be sufficient for the most common clinical applications.
Energy Technology Data Exchange (ETDEWEB)
Fediai, Artem, E-mail: artem.fediai@nano.tu-dresden.de; Ryndyk, Dmitry A. [Institute for Materials Science and Max Bergman Center of Biomaterials, TU Dresden, 01062 Dresden (Germany); Center for Advancing Electronics Dresden, TU Dresden, 01062 Dresden (Germany); Seifert, Gotthard [Theoretical Chemistry, TU Dresden, 01062 Dresden (Germany); Center for Advancing Electronics Dresden, TU Dresden, 01062 Dresden (Germany); Dresden Center for Computational Materials Science, TU Dresden, 01062 Dresden (Germany); Mothes, Sven; Schroter, Michael; Claus, Martin [Chair for Electron Devices and Integrated Circuits, TU Dresden, 01062 Dresden (Germany); Center for Advancing Electronics Dresden, TU Dresden, 01062 Dresden (Germany); Cuniberti, Gianaurelio [Institute for Materials Science and Max Bergman Center of Biomaterials, TU Dresden, 01062 Dresden (Germany); Center for Advancing Electronics Dresden, TU Dresden, 01062 Dresden (Germany); Dresden Center for Computational Materials Science, TU Dresden, 01062 Dresden (Germany)
2016-09-05
Using a dedicated combination of the non-equilibrium Green function formalism and large-scale density functional theory calculations, we investigated how incomplete metal coverage influences two of the most important electrical properties of carbon nanotube (CNT)-based transistors: contact resistance and its scaling with contact length, and maximum current. These quantities have been derived from parameter-free simulations of atomic systems that are as close as possible to experimental geometries. Physical mechanisms that govern these dependences have been identified for various metals, representing different CNT-metal interaction strengths from chemisorption to physisorption. Our results pave the way for an application-oriented design of CNT-metal contacts.
Microwave non-contact imaging of subcutaneous human body tissues.
Kletsov, Andrey; Chernokalov, Alexander; Khripkov, Alexander; Cho, Jaegeol; Druchinin, Sergey
2015-10-01
A small-size microwave sensor is developed for non-contact imaging of a human body structure in 2D, enabling fitness and health monitoring using mobile devices. A method for human body tissue structure imaging is developed and experimentally validated. Subcutaneous fat tissue reconstruction depth of up to 70 mm and maximum fat thickness measurement error below 2 mm are demonstrated by measurements with a human body phantom and human subjects. Electrically small antennas are developed for integration of the microwave sensor into a mobile device. Usability of the developed microwave sensor for fitness applications, healthcare, and body weight management is demonstrated.
Computational stress and damage modelling for rolling contact fatigue
DEFF Research Database (Denmark)
Cerullo, Michele
Rolling contact fatigue in radial roller bearings is studied by means of a 2D plane strain nite element program. The Dang Van multiaxial fatigue criterion is firstly used, in a macroscopic study modeling the bearing raceway, to investigate the region where fatigue cracks are more likely to nucleate...... and of compressive residual stresses are also analyzed. The stress history of a material point at the depth where the maximum Dang Van damage factor is reached is then recorded and used in a subsequent micro-mechanical analysis. The stress history is applied as periodic boundary conditions in a representative volume...
Coupled biomechanical response of the cornea assessed by non-contact tonometry. A simulation study.
Directory of Open Access Journals (Sweden)
Miguel Á Ariza-Gracia
Full Text Available The mechanical response of the cornea subjected to a non-contact air-jet tonometry diagnostic test represents an interplay between its geometry, the corneal material behavior and the loading. The objective is to study this interplay to better understand and interpret the results obtained with a non-contact tonometry test. A patient-specific finite element model of a healthy eye, accounting for the load free configuration, was used. The corneal tissue was modeled as an anisotropic hyperelastic material with two preferential directions. Three different sets of parameters within the human experimental range obtained from inflation tests were considered. The influence of the IOP was studied by considering four pressure levels (10-28 mmHg whereas the influence of corneal thickness was studied by inducing a uniform variation (300-600 microns. A Computer Fluid Dynamics (CFD air-jet simulation determined pressure loading exerted on the anterior corneal surface. The maximum apex displacement showed a linear variation with IOP for all materials examined. On the contrary, the maximum apex displacement followed a cubic relation with corneal thickness. In addition, a significant sensitivity of the apical displacement to the corneal stiffness was also obtained. Explanation to this behavior was found in the fact that the cornea experiences bending when subjected to an air-puff loading, causing the anterior surface to work in compression whereas the posterior surface works in tension. Hence, collagen fibers located at the anterior surface do not contribute to load bearing. Non-contact tonometry devices give useful information that could be misleading since the corneal deformation is the result of the interaction between the mechanical properties, IOP, and geometry. Therefore, a non-contact tonometry test is not sufficient to evaluate their individual contribution and a complete in-vivo characterization would require more than one test to independently determine
Contact isotopic- and contact ion-exchange between two adsorbents
International Nuclear Information System (INIS)
Bunzl, K.; Mohan, R.; Haimerl, M.
1975-01-01
The kinetics of contact ion exchange processes between an ion exchange membrane and resin ion exchange beads, stirred in pure water, was investigated. A general criterion was derived, which indicates whether diffusion of the ions between the intermingling electric double layers or the collision frequency between the two adsorbents is the rate dermining step. Since the latter process proved to be rate controlling under our experimental conditions, the corresponding rate equations were derived under various initial and boundary conditions. Experimentally, the kinetics of contact isotopic exchange of Cs + - and Na + -ions as well as of the reverse contact ion exchange process of Cs + -versus Na + -ions were investigated by using Na 22 and Cs 137 radioisotopes. The experiments reveal in quantitative accord with the theory that the rate of collision controlled contact ion exchange processes depends mainly on the 'exchange coefficient', the separation factor and the collision frequency. While the latter two quantities were determined independently by separate experiments, the 'exchange coefficient' was evaluated from a contact isotopic exchange experiment. (orig.) [de
ComplexContact: a web server for inter-protein contact prediction using deep learning
Zeng, Hong; Wang, Sheng; Zhou, Tianming; Zhao, Feifeng; Li, Xiufeng; Wu, Qing; Xu, Jinbo
2018-01-01
ComplexContact (http://raptorx2.uchicago.edu/ComplexContact/) is a web server for sequence-based interfacial residue-residue contact prediction of a putative protein complex. Interfacial residue-residue contacts are critical for understanding how proteins form complex and interact at residue level. When receiving a pair of protein sequences, ComplexContact first searches for their sequence homologs and builds two paired multiple sequence alignments (MSA), then it applies co-evolution analysis and a CASP-winning deep learning (DL) method to predict interfacial contacts from paired MSAs and visualizes the prediction as an image. The DL method was originally developed for intra-protein contact prediction and performed the best in CASP12. Our large-scale experimental test further shows that ComplexContact greatly outperforms pure co-evolution methods for inter-protein contact prediction, regardless of the species.
ComplexContact: a web server for inter-protein contact prediction using deep learning
Zeng, Hong
2018-05-20
ComplexContact (http://raptorx2.uchicago.edu/ComplexContact/) is a web server for sequence-based interfacial residue-residue contact prediction of a putative protein complex. Interfacial residue-residue contacts are critical for understanding how proteins form complex and interact at residue level. When receiving a pair of protein sequences, ComplexContact first searches for their sequence homologs and builds two paired multiple sequence alignments (MSA), then it applies co-evolution analysis and a CASP-winning deep learning (DL) method to predict interfacial contacts from paired MSAs and visualizes the prediction as an image. The DL method was originally developed for intra-protein contact prediction and performed the best in CASP12. Our large-scale experimental test further shows that ComplexContact greatly outperforms pure co-evolution methods for inter-protein contact prediction, regardless of the species.
ComplexContact: a web server for inter-protein contact prediction using deep learning.
Zeng, Hong; Wang, Sheng; Zhou, Tianming; Zhao, Feifeng; Li, Xiufeng; Wu, Qing; Xu, Jinbo
2018-05-22
ComplexContact (http://raptorx2.uchicago.edu/ComplexContact/) is a web server for sequence-based interfacial residue-residue contact prediction of a putative protein complex. Interfacial residue-residue contacts are critical for understanding how proteins form complex and interact at residue level. When receiving a pair of protein sequences, ComplexContact first searches for their sequence homologs and builds two paired multiple sequence alignments (MSA), then it applies co-evolution analysis and a CASP-winning deep learning (DL) method to predict interfacial contacts from paired MSAs and visualizes the prediction as an image. The DL method was originally developed for intra-protein contact prediction and performed the best in CASP12. Our large-scale experimental test further shows that ComplexContact greatly outperforms pure co-evolution methods for inter-protein contact prediction, regardless of the species.
Current knowledge on biomarkers for contact sensitization and allergic contact dermatitis.
Koppes, Sjors A; Engebretsen, Kristiane A; Agner, Tove; Angelova-Fischer, Irena; Berents, Teresa; Brandner, Johanna; Brans, Richard; Clausen, Maja-Lisa; Hummler, Edith; Jakasa, Ivone; Jurakić-Tončic, Ružica; John, Swen M; Khnykin, Denis; Molin, Sonja; Holm, Jan O; Suomela, Sari; Thierse, Hermann-Josef; Kezic, Sanja; Martin, Stefan F; Thyssen, Jacob P
2017-07-01
Contact sensitization is common and affects up to 20% of the general population. The clinical manifestation of contact sensitization is allergic contact dermatitis. This is a clinical expression that is sometimes difficult to distinguish from other types of dermatitis, for example irritant and atopic dermatitis. Several studies have examined the pathogenesis and severity of allergic contact dermatitis by measuring the absence or presence of various biomarkers. In this review, we provide a non-systematic overview of biomarkers that have been studied in allergic contact dermatitis. These include genetic variations and mutations, inflammatory mediators, alarmins, proteases, immunoproteomics, lipids, natural moisturizing factors, tight junctions, and antimicrobial peptides. We conclude that, despite the enormous amount of data, convincing specific biomarkers for allergic contact dermatitis are yet to be described. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Quaternionic contact Einstein structures and the quaternionic contact Yamabe problem
Ivanov, Stefan; Vassilev, Dimiter
2014-01-01
A partial solution of the quaternionic contact Yamabe problem on the quaternionic sphere is given. It is shown that the torsion of the Biquard connection vanishes exactly when the trace-free part of the horizontal Ricci tensor of the Biquard connection is zero and this occurs precisely on 3-Sasakian manifolds. All conformal transformations sending the standard flat torsion-free quaternionic contact structure on the quaternionic Heisenberg group to a quaternionic contact structure with vanishing torsion of the Biquard connection are explicitly described. A "3-Hamiltonian form" of infinitesimal conformal automorphisms of quaternionic contact structures is presented.
Contact Dermatitis in Pediatrics.
Pelletier, Janice L; Perez, Caroline; Jacob, Sharon E
2016-08-01
Contact dermatitis is an umbrella term that describes the skin's reaction to contacted noxious or allergenic substances. The two main categories of contact dermatitis are irritant type and allergic type. This review discusses the signs, symptoms, causes, and complications of contact dermatitis. It addresses the testing, treatment, and prevention of contact dermatitis. Proper management of contact dermatitis includes avoidance measures for susceptible children. Implementation of a nickel directive (regulating the use of nickel in jewelry and other products that come into contact with the skin) could further reduce exposure to the most common allergens in the pediatric population. [Pediatr Ann. 2016;45(8):e287-e292.]. Copyright 2016, SLACK Incorporated.
Effects of contact structure on the transient evolution of HIV virulence.
Directory of Open Access Journals (Sweden)
Sang Woo Park
2017-03-01
Full Text Available Early in an epidemic, high densities of susceptible hosts select for relatively high parasite virulence; later in the epidemic, lower susceptible densities select for lower virulence. Thus over the course of a typical epidemic the average virulence of parasite strains increases initially, peaks partway through the epidemic, then declines again. However, precise quantitative outcomes, such as the peak virulence reached and its timing, may depend sensitively on epidemiological details. Fraser et al. proposed a model for the eco-evolutionary dynamics of HIV that incorporates the tradeoffs between transmission and virulence (mediated by set-point viral load, SPVL and their heritability between hosts. Their model used implicit equations to capture the effects of partnership dynamics that are at the core of epidemics of sexually transmitted diseases. Our models combine HIV virulence tradeoffs with a range of contact models, explicitly modeling partnership formation and dissolution and allowing for individuals to transmit disease outside of partnerships. We assess summary statistics such as the peak virulence (corresponding to the maximum value of population mean log10 SPVL achieved throughout the epidemic across models for a range of parameters applicable to the HIV epidemic in sub-Saharan Africa. Although virulence trajectories are broadly similar across models, the timing and magnitude of the virulence peak vary considerably. Previously developed implicit models predicted lower virulence and slower progression at the peak (a maximum of 3.5 log10 SPVL compared both to more realistic models and to simple random-mixing models with no partnership structure at all (both with a maximum of ≈ 4.7 log10 SPVL. In this range of models, the simplest random-mixing structure best approximates the most realistic model; this surprising outcome occurs because the dominance of extra-pair contact in the realistic model swamps the effects of partnership structure.
Projecting social contact matrices in 152 countries using contact surveys and demographic data.
Directory of Open Access Journals (Sweden)
Kiesha Prem
2017-09-01
Full Text Available Heterogeneities in contact networks have a major effect in determining whether a pathogen can become epidemic or persist at endemic levels. Epidemic models that determine which interventions can successfully prevent an outbreak need to account for social structure and mixing patterns. Contact patterns vary across age and locations (e.g. home, work, and school, and including them as predictors in transmission dynamic models of pathogens that spread socially will improve the models' realism. Data from population-based contact diaries in eight European countries from the POLYMOD study were projected to 144 other countries using a Bayesian hierarchical model that estimated the proclivity of age-and-location-specific contact patterns for the countries, using Markov chain Monte Carlo simulation. Household level data from the Demographic and Health Surveys for nine lower-income countries and socio-demographic factors from several on-line databases for 152 countries were used to quantify similarity of countries to estimate contact patterns in the home, work, school and other locations for countries for which no contact data are available, accounting for demographic structure, household structure where known, and a variety of metrics including workforce participation and school enrolment. Contacts are highly assortative with age across all countries considered, but pronounced regional differences in the age-specific contacts at home were noticeable, with more inter-generational contacts in Asian countries than in other settings. Moreover, there were variations in contact patterns by location, with work-place contacts being least assortative. These variations led to differences in the effect of social distancing measures in an age structured epidemic model. Contacts have an important role in transmission dynamic models that use contact rates to characterize the spread of contact-transmissible diseases. This study provides estimates of mixing patterns for
Projecting social contact matrices in 152 countries using contact surveys and demographic data.
Prem, Kiesha; Cook, Alex R; Jit, Mark
2017-09-01
Heterogeneities in contact networks have a major effect in determining whether a pathogen can become epidemic or persist at endemic levels. Epidemic models that determine which interventions can successfully prevent an outbreak need to account for social structure and mixing patterns. Contact patterns vary across age and locations (e.g. home, work, and school), and including them as predictors in transmission dynamic models of pathogens that spread socially will improve the models' realism. Data from population-based contact diaries in eight European countries from the POLYMOD study were projected to 144 other countries using a Bayesian hierarchical model that estimated the proclivity of age-and-location-specific contact patterns for the countries, using Markov chain Monte Carlo simulation. Household level data from the Demographic and Health Surveys for nine lower-income countries and socio-demographic factors from several on-line databases for 152 countries were used to quantify similarity of countries to estimate contact patterns in the home, work, school and other locations for countries for which no contact data are available, accounting for demographic structure, household structure where known, and a variety of metrics including workforce participation and school enrolment. Contacts are highly assortative with age across all countries considered, but pronounced regional differences in the age-specific contacts at home were noticeable, with more inter-generational contacts in Asian countries than in other settings. Moreover, there were variations in contact patterns by location, with work-place contacts being least assortative. These variations led to differences in the effect of social distancing measures in an age structured epidemic model. Contacts have an important role in transmission dynamic models that use contact rates to characterize the spread of contact-transmissible diseases. This study provides estimates of mixing patterns for societies for which
Contact allergy and allergic contact dermatitis in adolescents: prevalence measures and associations
DEFF Research Database (Denmark)
Mørtz, Charlotte G; Lauritsen, Jens Martin; Bindslev-Jensen, Carsten
2002-01-01
The aims of this cross-sectional study were to establish the prevalence measures of contact allergy and allergic contact dermatitis in 8th grade schoolchildren (aged 12-16 years) in Odense, Denmark, and to examine the associations with atopic dermatitis, inhalant allergy and hand eczema. Contact...... allergy to a standard series allergen was found in 15.2% of schoolchildren. The point prevalence of allergic contact dermatitis was 0.7% and the lifetime prevalence 7.2%, predominantly in girls. The most common contact allergens were nickel (8.6%) and fragrance mix (1.8%). Nickel allergy was clinically...... relevant in 69% and fragrance allergy in 29% of cases. A significant association was found between contact allergy and hand eczema while no association was found between contact allergy and atopic dermatitis or inhalant allergy. In the future this cohort of schoolchildren will be followed with regard...
Current knowledge on biomarkers for contact sensitization and allergic contact dermatitis
Koppes, Sjors A.; Engebretsen, Kristiane A.; Agner, Tove; Angelova-Fischer, Irena; Berents, Teresa; Brandner, Johanna; Brans, Richard; Clausen, Maja-Lisa; Hummler, Edith; Jakasa, Ivone; Jurakić-Tončic, Ružica; John, Swen M.; Khnykin, Denis; Molin, Sonja; Holm, Jan O.; Suomela, Sari; Thierse, Hermann-Josef; Kezic, Sanja; Martin, Stefan F.; Thyssen, Jacob P.
2017-01-01
Contact sensitization is common and affects up to 20% of the general population. The clinical manifestation of contact sensitization is allergic contact dermatitis. This is a clinical expression that is sometimes difficult to distinguish from other types of dermatitis, for example irritant and
Relationship between the real contact area and contact force in pre-sliding regime
International Nuclear Information System (INIS)
Song Baojiang; Yan Shaoze
2017-01-01
The pre-sliding regime is typically neglected in the dynamic modelling of mechanical systems. However, the change in contact state caused by static friction may decrease positional accuracy and control precision. To investigate the relationship between contact status and contact force in pre-sliding friction, an optical experimental method is presented in this paper. With this method, the real contact state at the interface of a transparent material can be observed based on the total reflection principle of light by using an image processing technique. A novel setup, which includes a pair of rectangular trapezoidal blocks, is proposed to solve the challenging issue of accurately applying different tangential and normal forces to the contact interface. The improved Otsu’s method is used for measurement. Through an experimental study performed on polymethyl methacrylate (PMMA), the quantity of contact asperities is proven to be the dominant factor that affects the real contact area. The relationship between the real contact area and the contact force in the pre-sliding regime is studied, and the distribution of static friction at the contact interface is qualitatively discussed. New phenomena in which the real contact area expands along with increasing static friction are identified. The aforementioned relationship is approximately linear at the contact interface under a constant normal pressure, and the distribution of friction stress decreases from the leading edge to the trailing edge. (paper)
... There is a risk of eye infection from bacteria in swimming pool water, hot tubs, lakes and the ocean Replace your contact lens storage case every 3 months or as directed by your eye care professional. Other Risks of Contact Lenses Other risks of contact lenses include pink eye ( ...
Noneczematous Contact Dermatitis
Foti, Caterina; Vestita, Michelangelo; Angelini, Gianni
2013-01-01
Irritant or allergic contact dermatitis usually presents as an eczematous process, clinically characterized by erythematoedematovesicous lesions with intense itching in the acute phase. Such manifestations become erythematous-scaly as the condition progresses to the subacute phase and papular-hyperkeratotic in the chronic phase. Not infrequently, however, contact dermatitis presents with noneczematous features. The reasons underlying this clinical polymorphism lie in the different noxae and contact modalities, as well as in the individual susceptibility and the various targeted cutaneous structures. The most represented forms of non-eczematous contact dermatitis include the erythema multiforme-like, the purpuric, the lichenoid, and the pigmented kinds. These clinical entities must obviously be discerned from the corresponding “pure” dermatitis, which are not associated with contact with exogenous agents. PMID:24109520
Apparent Contact Angle and Contact Angle Hysteresis on Liquid Infused Surfaces
Semprebon, Ciro; McHale, Glen; Kusumaatmaja, Halim
2016-01-01
We theoretically investigate the apparent contact angle and contact angle hysteresis of a droplet placed on a liquid infused surface. We show that the apparent contact angle is not uniquely defined by material parameters, but also has a strong dependence on the relative size between the droplet and its surrounding wetting ridge formed by the infusing liquid. We derive a closed form expression for the contact angle in the limit of vanishing wetting ridge, and compute the correction for small b...
Contact with turf algae alters the coral microbiome: contact versus systemic impacts
Pratte, Zoe A.; Longo, Guilherme O.; Burns, Andrew S.; Hay, Mark E.; Stewart, Frank J.
2018-03-01
Coral reefs are degrading to algae-dominated reefs worldwide, with alterations of coral microbiomes commonly co-occurring with reef demise. The severe thermal anomaly during the 2016 El Niño event in the South Pacific killed many corals and stressed others. We examined the microbiome of turf algae and of the coral Porites sp. in contact with turf during this thermal event to investigate algal turf effects on the coral microbiome during a period of environmental stress. The microbial composition of turf did not differ between coral-contacted and non-contacted turfs. However, microbiomes of corals in direct contact with turf were similar to those of the turf microbiome, but differed significantly from coral portions 5 cm from the point of turf/coral contact and from portions of the coral that looked most healthy, regardless of location. Although the majority of significant differences occurred in coral samples at the point of contact, a small subset of microbial taxa was enriched in coral tissues taken 5 cm from turf contact compared to all other sample types, including samples from areas of the coral that appeared most healthy. These results suggest that the coral microbiome is susceptible to colonization by microbes from turf, but not vice versa. Results also suggest that algal contact elicits a subtle shift in the coral microbiome just beyond the contact site. The combination of turf microbiome stability and coral microbiome vulnerability at areas of contact may contribute to the continued decline in coral cover and increase in algal cover associated with coral-algae phase shifts.
Patients with multiple contact allergies
DEFF Research Database (Denmark)
Carlsen, Berit Christina; Andersen, Klaus Ejner; Menné, Torkil
2008-01-01
Patients with multiple contact allergies, also referred to as polysensitized, are more frequent than predicted from prevalence of single sensitivities. The understanding of why some people develop multiple contact allergies, and characterization of patients with multiple contact allergies...... of developing multiple contact allergies. Evidence of allergen clusters among polysensitized individuals is also reviewed. The literature supports the idea that patients with multiple contact allergies constitute a special entity within the field of contact allergy. There is no generally accepted definition...... of patients with multiple contact allergies. We suggest that contact allergy to 3 or more allergens are defined as multiple contact allergies....
Power density of piezoelectric transformers improved using a contact heat transfer structure.
Shao, Wei Wei; Chen, Li Juan; Pan, Cheng Liang; Liu, Yong Bin; Feng, Zhi Hua
2012-01-01
Based on contact heat transfer, a novel method to increase power density of piezoelectric transformers is proposed. A heat transfer structure is realized by directly attaching a dissipater to the piezoelectric transformer plate. By maintaining the vibration mode of the transformer and limiting additional energy losses from the contact interface, an appropriate design can improve power density of the transformer on a large scale, resulting from effective suppression of its working temperature rise. A prototype device was fabricated from a rectangular piezoelectric transformer, a copper heat transfer sheet, a thermal grease insulation pad, and an aluminum heat radiator. The experimental results show the transformer maintains a maximum power density of 135 W/cm(3) and an efficiency of 90.8% with a temperature rise of less than 10 °C after more than 36 h, without notable changes in performance. © 2012 IEEE
[MAXIMUM SINGLE DOSE OF COLLOIDAL SILVER NEGATIVELY AFFECTS ERYTHROPOIESIS IN VITRO].
Tishevskayal, N V; Zakharovl, Y M; Bolotovl, A A; Arkhipenko, Yu V; Sazontova, T G
2015-01-01
Erythroblastic islets (EI) of rat bone marrow were cultured for 24 h in the presence of silver nanoparticles (1.07 · 10(-4) mg/ml; 1.07 · 10(-3) mg/ml; and 1.07 · 10(-2) mg/mL). The colloidal silver at 1.07 · 10(-3) mg/ml concentration inhibited the formation of new Elby disrupting contacts of bone marrow macrophages with CFU-E (erythropoiesis de novo) by 65.3% (p Colloidal silver nanoparticles suppressed the reconstruction of erythropoiesis and inhibited the formation of new EI by disrupting contacts of CFU-E and central macrophages with matured erythroidal "crown" (erythropoiesis de repeto). The colloidal silver concentration of 1.07 · 10(-3) mg/ml in the culture medium also reduced the number of self-reconstructing EI by 67.5% (p colloidal silver reduced this value by 93.7% (p Silver nanoparticles retarded maturation of erythroid cells at the stage of oxiphylic normoblast denucleation: 1.07 · 10(-3) mg/ml colloidal silver increased the number of mature El by 53% (p colloidal silver in concentration equivalent to the maximum single dose is related to the effect of silver nanoparticles rather than glycerol present in the colloidal suspension.
Noda, Kei; Wada, Yasuo; Toyabe, Toru
2015-10-28
Effects of contact-area-limited doping for pentacene thin-film transistors with a bottom-gate, top-contact configuration were investigated. The increase in the drain current and the effective field-effect mobility was achieved by preparing hole-doped layers underneath the gold contact electrodes by coevaporation of pentacene and 2,3,5,6-tetrafluoro-7,7,8,8-tetracyanoquinodimethane (F4TCNQ), confirmed by using a thin-film organic transistor advanced simulator (TOTAS) incorporating Schottky contact with a thermionic field emission (TFE) model. Although the simulated electrical characteristics fit the experimental results well only in the linear regime of the transistor operation, the barrier height for hole injection and the gate-voltage-dependent hole mobility in the pentacene transistors were evaluated with the aid of the device simulation. This experimental data analysis with the simulation indicates that the highly-doped semiconducting layers prepared in the contact regions can enhance the charge carrier injection into the active semiconductor layer and concurrent trap filling in the transistor channel, caused by the mitigation of a Schottky energy barrier. This study suggests that both the contact-area-limited doping and the device simulation dealing with Schottky contact are indispensable in designing and developing high-performance organic thin-film transistors.
Ahmad, Samir Mahmmod; Leong, Cheow Siu; Sopian, K.; Zaidi, Saleem H.
2018-03-01
Formation of an Ohmic contact requires a suitable firing temperature, appropriate doping profile, and contact dimensions within resolution limits of the screen-printing process. In this study, the role of the peak firing temperature in standard rapid thermal annealing (RTA) six-zone conveyor belt furnace (CBF) and two inexpensive alternate RTA systems [a custom-designed, three-zone, 5″-diameter quartz tube furnace (QTF) and a tabletop, 3″-diameter rapid thermal processing (RTP)] has been investigated. In addition, the role of sheet resistance and contact area in achieving low-resistance ohmic contacts has been examined. Electrical measurements of ohmic contacts between silver paste/ n +-emitter layer with varying sheet resistances and aluminum paste/ p-doped wafer were carried out in transmission line method configuration. Experimental measurements of the contact resistivity ( ρ c) exhibited the lowest values for CBF at 0.14 mΩ cm2 for Ag and 100 mΩ cm2 for Al at a peak firing temperature of 870°C. For the QTF configuration, lowest measured contact resistivities were 3.1 mΩ cm2 for Ag and 74.1 mΩ cm2 for Al at a peak firing temperature of 925°C. Finally, for the RTP configuration, lowest measured contact resistivities were 1.2 mΩ cm2 for Ag and 68.5 mΩ cm2 for Al at a peak firing temperature of 780°C. The measured contact resistivity exhibits strong linear dependence on sheet resistance. The contact resistivity for Ag decreases with contact area, while for Al the opposite behavior is observed.
An approximate JKR solution for a general contact, including rough contacts
Ciavarella, M.
2018-05-01
In the present note, we suggest a simple closed form approximate solution to the adhesive contact problem under the so-called JKR regime. The derivation is based on generalizing the original JKR energetic derivation assuming calculation of the strain energy in adhesiveless contact, and unloading at constant contact area. The underlying assumption is that the contact area distributions are the same as under adhesiveless conditions (for an appropriately increased normal load), so that in general the stress intensity factors will not be exactly equal at all contact edges. The solution is simply that the indentation is δ =δ1 -√{ 2 wA‧ /P″ } where w is surface energy, δ1 is the adhesiveless indentation, A‧ is the first derivative of contact area and P‧‧ the second derivative of the load with respect to δ1. The solution only requires macroscopic quantities, and not very elaborate local distributions, and is exact in many configurations like axisymmetric contacts, but also sinusoidal waves contact and correctly predicts some features of an ideal asperity model used as a test case and not as a real description of a rough contact problem. The solution permits therefore an estimate of the full solution for elastic rough solids with Gaussian multiple scales of roughness, which so far was lacking, using known adhesiveless simple results. The result turns out to depend only on rms amplitude and slopes of the surface, and as in the fractal limit, slopes would grow without limit, tends to the adhesiveless result - although in this limit the JKR model is inappropriate. The solution would also go to adhesiveless result for large rms amplitude of roughness hrms, irrespective of the small scale details, and in agreement with common sense, well known experiments and previous models by the author.
International Nuclear Information System (INIS)
Herrmann, K.
1994-03-01
In this work the properties of josephson step contacts are investigated. After a short introduction into Josephson step contacts the structure, properties and the Josphson contacts of YBa 2 Cu 3 O 7-x high-T c superconductors is presented. The fabrication of HTSC step contacts and the microstructure is discussed. The electric properties of these contacts are measured together with the Josephson emission and the magnetic field dependence. The temperature dependence of the stationary transport properties is given. (WL)
International Nuclear Information System (INIS)
Fujimoto, Nozomu; Maruyama, Soh; Sudo, Yukio; Fujii, Sadao; Niguma, Yoshinori.
1988-10-01
This report presents the results of quantitative evaluation on the effects of the dominant parameters on the maximum fuel temperature in the core thermal hydraulic design of the High Temperature Engineering Test Reactor(HTTR) of 30 MW in thermal power, 950 deg C in reactor outlet coolant temperature and 40 kg/cm 2 G in coolant pressure. The dominant parameters investigated are 1) Gap conductance. 2) Effect of eccertricity of fuel compacts in graphite sleeve. 3) Effect of spacer ribs on heat transfer coefficients. 4) Contact probability of fuel compact and graphite sleeve. 5) Validity of uniform radial power density in the fuel compacts. 6) Effect of impurity gas on gap conductance. 7) Effect of FP gas on gap conductance. The effects of these items on the maximum fuel temperature were quantitalively identified as hot spot factors. A probability of the appearance of the maximum fuel temperature was also evaluated in this report. (author)
Adhikari, Badri; Cheng, Jianlin
2017-08-29
Residue-residue contacts are key features for accurate de novo protein structure prediction. For the optimal utilization of these predicted contacts in folding proteins accurately, it is important to study the challenges of reconstructing protein structures using true contacts. Because contact-guided protein modeling approach is valuable for predicting the folds of proteins that do not have structural templates, it is necessary for reconstruction studies to focus on hard-to-predict protein structures. Using a data set consisting of 496 structural domains released in recent CASP experiments and a dataset of 150 representative protein structures, in this work, we discuss three techniques to improve the reconstruction accuracy using true contacts - adding secondary structures, increasing contact distance thresholds, and adding non-contacts. We find that reconstruction using secondary structures and contacts can deliver accuracy higher than using full contact maps. Similarly, we demonstrate that non-contacts can improve reconstruction accuracy not only when the used non-contacts are true but also when they are predicted. On the dataset consisting of 150 proteins, we find that by simply using low ranked predicted contacts as non-contacts and adding them as additional restraints, can increase the reconstruction accuracy by 5% when the reconstructed models are evaluated using TM-score. Our findings suggest that secondary structures are invaluable companions of contacts for accurate reconstruction. Confirming some earlier findings, we also find that larger distance thresholds are useful for folding many protein structures which cannot be folded using the standard definition of contacts. Our findings also suggest that for more accurate reconstruction using predicted contacts it is useful to predict contacts at higher distance thresholds (beyond 8 Å) and predict non-contacts.
Rolling contact fatigue in a vacuum test equipment and coating analysis
Danyluk, Michael
2014-01-01
This book deals with wear and performance testing of thin solid film lubrication and hard coatings in an ultra-high vacuum (UHV), a process which enables rapid accumulation of stress cycles compared with testing in oil at atmospheric pressure. The authors' lucid and authoritative narrative broadens readers' understanding of the benefits of UHV testing: a cleaner, shorter test is achieved in high vacuum, disturbance rejection by the deposition controller may be optimized for maximum fatigue life of the coating using rolling contact fatigue testing (RCF) in a high vacuum, and RCF testing in UHV
Contact angle measurements of a polyphenyl ether to 190 C on M-50 steel
Jones, W. R., Jr.
1981-01-01
Contact angle measurements were performed for a polyphenyl ether on steel in nitrogen. A tilting plate and a sessile drop apparatus were used. Surface tension was measured with a maximum bubble pressure apparatus. Critical surface energies of spreading were found to be 30.1 and 31.3 dynes/cm. It was concluded that the polyphenyl ether is inherently autophobic and will not spread on its own surface film.
Effect of implanted doses of N+-ions on the contact resistance of copper contacts
International Nuclear Information System (INIS)
Dubravec, B.; Kovac, P.; Lipka, F.; Padysak, M.
1997-01-01
The paper deals with the effect of implanted doses of N + ions on the contact resistance. Dependencies of the contact resistance versus contact force R c =f(F c ) and microhardness of implanted surfaces were measured for three implanted profiles. The influence of the aggressive environs on the contact resistance of implanted contact is given too
Cosmic shear measurement with maximum likelihood and maximum a posteriori inference
Hall, Alex; Taylor, Andy
2017-06-01
We investigate the problem of noise bias in maximum likelihood and maximum a posteriori estimators for cosmic shear. We derive the leading and next-to-leading order biases and compute them in the context of galaxy ellipticity measurements, extending previous work on maximum likelihood inference for weak lensing. We show that a large part of the bias on these point estimators can be removed using information already contained in the likelihood when a galaxy model is specified, without the need for external calibration. We test these bias-corrected estimators on simulated galaxy images similar to those expected from planned space-based weak lensing surveys, with promising results. We find that the introduction of an intrinsic shape prior can help with mitigation of noise bias, such that the maximum a posteriori estimate can be made less biased than the maximum likelihood estimate. Second-order terms offer a check on the convergence of the estimators, but are largely subdominant. We show how biases propagate to shear estimates, demonstrating in our simple set-up that shear biases can be reduced by orders of magnitude and potentially to within the requirements of planned space-based surveys at mild signal-to-noise ratio. We find that second-order terms can exhibit significant cancellations at low signal-to-noise ratio when Gaussian noise is assumed, which has implications for inferring the performance of shear-measurement algorithms from simplified simulations. We discuss the viability of our point estimators as tools for lensing inference, arguing that they allow for the robust measurement of ellipticity and shear.
Electrical contacts principles and applications
Slade, Paul G
2013-01-01
Covering the theory, application, and testing of contact materials, Electrical Contacts: Principles and Applications, Second Edition introduces a thorough discussion on making electric contact and contact interface conduction; presents a general outline of, and measurement techniques for, important corrosion mechanisms; considers the results of contact wear when plug-in connections are made and broken; investigates the effect of thin noble metal plating on electronic connections; and relates crucial considerations for making high- and low-power contact joints. It examines contact use in switch
International Nuclear Information System (INIS)
Czaplewski, David A; Nordquist, Christopher D; Dyck, Christopher W; Patrizi, Gary A; Kraus, Garth M; Cowan, William D
2012-01-01
We present lifetime limitations and failure analysis of many packaged RF MEMS ohmic contacting switches with Au–Au, Au–Ir, and Au–Pt contact materials operating with 100 µN of contact force per contact in hermetically sealed glass wall packages. All metals were tested using the same switch design in a controlled environment to provide a comparison between the performance of the different materials and their corresponding failure mechanisms. The switch lifetimes of the different contact materials varied from several hundred cycles to 200 million cycles with different mechanisms causing failures for different contact materials. Switches with Au–Au contacts failed due to adhesion when thoroughly cleaned while switches with dissimilar metal contacts (Au–Ir and Au–Pt) operated without adhesion failures but failed due to carbon accumulation on the contacts even in a clean, packaged environment as a result of the catalytic behavior of the contact materials. Switch lifetimes correlated inversely with catalytic behavior of the contact metals. The data suggests the path to increase switch lifetime is to use favorable catalytic materials as contacts, design switches with higher contact forces to break through any residual contamination, and use cleaner, probably smaller, packages. (paper)
Czech Academy of Sciences Publication Activity Database
Graf, Sylvie; Paolini, S.; Rubin, M.
2014-01-01
Roč. 44, č. 96 (2014), 536–547 ISSN 0046-2772 R&D Projects: GA ČR GA13-25656S Institutional support: RVO:68081740 Keywords : intergroup contact * negative contact * outgroup attitudes Subject RIV: AN - Psychology Impact factor: 1.712, year: 2014
Federal Laboratory Consortium — Description:The FTA32 goniometer provides video-based contact angle and surface tension measurement. Contact angles are measured by fitting a mathematical expression...
Piotrowski, Jerzy
1991-10-01
Investigation of contact mechanical nonlinearities of a mathematical model of corrugation revealed that the typical shape of contact patch resembles a falling drop of water. A contact patch of that shape was approximated with a figure composed of two parts of ellipses with different eccentricities. The contact pressure distribution was assumed as a smoothing ensemble of two paraboloidal distributions. The description of a general case of double half elliptical contact area was given but a special case of double half elliptical contact is more interesting as it possesses some Hertzian properties. It was shown how three geometrical parameters of double half elliptical contact can be chosen when actual, non-Hertzian contact is known. A linear theory was written which indicates that the lateral vibrations of the rail may be excited only due to shape variation on corrugation even if any other cause for these vibrations does not exist. For nonlinear theory a computer program, based on FASTSIM algorithm by Kalker, was written. The aim is to calculate the creep forces and frictional power density distribution over the contact area. Also, a graphic program visualizing the solution was written. Numerical results are not provided; unattended and unsolved problems relevant for this type of contact are listed.
2013-03-06
...] National Contact Center; Information Collection; National Contact Center Customer Evaluation Survey AGENCY... National Contact Center customer evaluation surveys. In this request, the previously approved surveys have... several months. These temporary surveys will allow the National Contact Center to compare its customer...
A contact angle hysteresis model based on the fractal structure of contact line.
Wu, Shuai; Ma, Ming
2017-11-01
Contact angle is one of the most popular concept used in fields such as wetting, transport and microfludics. In practice, different contact angles such as equilibrium, receding and advancing contact angles are observed due to hysteresis. The connection among these contact angles is important in revealing the chemical and physical properties of surfaces related to wetting. Inspired by the fractal structure of contact line, we propose a single parameter model depicting the connection of the three angles. This parameter is decided by the fractal structure of the contact line. The results of this model agree with experimental observations. In certain cases, it can be reduced to other existing models. It also provides a new point of view in understanding the physical nature of the contact angle hysteresis. Interestingly, some counter-intuitive phenomena, such as the binary receding angles, are indicated in this model, which are waited to be validated by experiments. Copyright © 2017 Elsevier Inc. All rights reserved.
Mechanical Contact Experiments and Simulations
DEFF Research Database (Denmark)
Nielsen, Chris Valentin; Martins, P; Zhang, W.
2011-01-01
Mechanical contact is studied under dynamic development by means of a combined numerical and experimental investigation. The experiments are designed to allow dynamical development of non-planar contact areas with significant expansion in all three directions as the load is increased. Different....... The overall investigation serves for testing and validating the numerical implementation of the mechanical contact, which is one of the main contributions to a system intended for 3D simulation of resistance welding. Correct modelling of contact between parts to be welded, as well as contact with electrodes......, is crucial for satisfactory modelling of the resistance welding process. The resistance heating at the contact interfaces depends on both contact area and pressure, and as the contact areas develop dynamically, the presented tests are relevant for assessing the validity and accuracy of the mechanical contact...
Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...
Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...
Churchill, Nathan W; Hutchison, Michael G; Di Battista, Alex P; Graham, Simon J; Schweizer, Tom A
2017-01-01
There is growing concern about how participation in contact sports affects the brain. Retrospective evidence suggests that contact sports are associated with long-term negative health outcomes. However, much of the research to date has focused on former athletes with significant health problems. Less is known about the health of current athletes in contact and collision sports who have not reported significant medical issues. In this cross-sectional study, advanced magnetic resonance imaging (MRI) was used to evaluate multiple aspects of brain physiology in three groups of athletes participating in non-contact sports ( N = 20), contact sports ( N = 22), and collision sports ( N = 23). Diffusion tensor imaging was used to assess white matter microstructure based on measures of fractional anisotropy (FA) and mean diffusivity (MD); resting-state functional MRI was used to evaluate global functional connectivity; single-voxel spectroscopy was used to compare ratios of neural metabolites, including N -acetyl aspartate (NAA), creatine (Cr), choline, and myo-inositol. Multivariate analysis revealed structural, functional, and metabolic measures that reliably differentiated between sport groups. The collision group had significantly elevated FA and reduced MD in white matter, compared to both contact and non-contact groups. In contrast, the collision group showed significant reductions in functional connectivity and the NAA/Cr metabolite ratio, relative to only the non-contact group, while the contact group overlapped with both non-contact and collision groups. For brain regions associated with contact sport participation, athletes with a history of concussion also showed greater alterations in FA and functional connectivity, indicating a potential cumulative effect of both contact exposure and concussion history on brain physiology. These findings indicate persistent differences in brain physiology for athletes participating in contact and collision sports
Evaluation of contact sensitivity to topical drugs in patients with contact dermatitis
Directory of Open Access Journals (Sweden)
Bilge Bülbül Şen
2013-03-01
Full Text Available Background and Design: Topical drugs are an important group of contact allergens. The present study aimed to evaluate contact sensitivity to topical drugs in patients with contact dermatitis. Materials and Methods: Between 2003 and 2008, 129 patients were followed up at the Department of Dermatology at Ankara University School of Medicine with clinically suspected contact sensitivity to topical drugs. In this study, the patch test reactions to the European Standard Battery and topical drugs used by the patients and medicament patch test results were evaluated. Results: Positive patch test reaction to one or more allergens was found in 80 (62.0% of 129 patients included in the study. Sixty-one of the 80 patients (61/129, 47.3% had positive patch test reaction to medicaments. Medicament sensitivity was detected in 37.9% (49/129 of subjects. Nitrofurazone was found to be the most common allergen (18.6%. Discussion: The present study showed that topical drugs are a frequent cause of allergic contact dermatitis. Therefore, the probability of contact sensitivity to topical drugs should also be considered in patients with the clinical diagnosis of allergic contact dermatitis and, suspected cases should be evaluated further with patch testing in order to find the responsible allergens.
Maximum Acceleration Recording Circuit
Bozeman, Richard J., Jr.
1995-01-01
Coarsely digitized maximum levels recorded in blown fuses. Circuit feeds power to accelerometer and makes nonvolatile record of maximum level to which output of accelerometer rises during measurement interval. In comparison with inertia-type single-preset-trip-point mechanical maximum-acceleration-recording devices, circuit weighs less, occupies less space, and records accelerations within narrower bands of uncertainty. In comparison with prior electronic data-acquisition systems designed for same purpose, circuit simpler, less bulky, consumes less power, costs and analysis of data recorded in magnetic or electronic memory devices. Circuit used, for example, to record accelerations to which commodities subjected during transportation on trucks.
Möhlhenrich, Stephan Christian; Kamal, Mohammad; Peters, Florian; Fritz, Ulrike; Hölzle, Frank; Modabber, Ali
2016-04-01
The most common way to move the mandible during orthognathic surgery is by bilateral sagittal split osteotomy (BSSO). The high-oblique sagittal split osteotomy (HSSO) is an alternative, although its use is limited by potential complications, mainly to do with the position of the condyle and reduced contact with bone. The aim of this study was to find out the optimal intercondylar distance and area of contact with the surface of the bone for mandibular advancement and setback in BSSO and HSSO. Data from computed tomographic (CT) images from 40 patients were loaded into special planning software, and virtual operations done for mandibular advancement and setback at 3, 5, 8, and 10mm using BSSO and HSSO, which resulted in 640 individual mandibular displacements. The resultant area of bony contact and intercondylar distance were calculated by the software. The mean (SD) areas of contact with the bony surface after 10mm advancement for HSSO and BSSO were 193.94 (63.76) mm(2) and 967.92 (229.21) mm(2), respectively, and after 10mm setback 202.64 (62.30) mm(2) and 1108.86 (247.38) mm(2). The mean corresponding intercondylar distance after maximum advancement were 86.76 (6.40) mm and 86.59 (6.24) mm, and after maximum setback 74.90 (5.73) mm and 73.06 (6.06) mm. There were significant differences between the two for the area of contact with the surface at each displacement distance (parea of bony contact can be expected at any displacement distance for BSSO, so the changes in intercondylar distance should not be considered when deciding which osteotomy to select. Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Piotrowski, J.
2010-07-01
This paper presents two extensions of Kalker's algorithm Fastsim of the simplified theory of rolling contact. The first extension is for solving tangential contact problems with the coefficient of friction depending on slip velocity. Two friction laws have been considered: with and without recuperation of the static friction. According to the tribological hypothesis for metallic bodies shear failure, the friction law without recuperation of static friction is more suitable for wheel and rail than the other one. Sample results present local quantities inside the contact area (division to slip and adhesion, traction) as well as global ones (creep forces as functions of creepages and rolling velocity). For the coefficient of friction diminishing with slip, the creep forces decay after reaching the maximum and they depend on the rolling velocity. The second extension is for solving tangential contact problems with friction anisotropy characterised by a convex set of the permissible tangential tractions. The effect of the anisotropy has been shown on examples of rolling without spin and in the presence of pure spin for the elliptical set. The friction anisotropy influences tangential tractions and creep forces. Sample results present local and global quantities. Both extensions have been described with the same language of formulation and they may be merged into one, joint algorithm.
This picture shows a skin inflammation (dermatitis) caused by contact with a material that causes an allergic reaction in this person. Contact dermatitis is a relatively common condition, and can be caused ...
[News on occupational contact dermatitis].
Crépy, Marie-Noëlle; Bensefa-Colas, Lynda
2014-03-01
Contact dermatitis--irritant contact dermatitis, allergic contact dermatitis and protein contact dermatitis--are the most common occupational skin diseases, most often localized to the hands. Contact urticaria is rarer The main occupational irritants are wet work, detergents and disinfectants, cutting oils, and solvents. The main occupational allergens are rubber additives, metals (chromium, nickel, cobalt), plastics (epoxy resins, acrylic), biocides and plants. Diagnosis is based on clinical examination, medical history and allergy testing. For a number of irritating or sensitizing agents, irritant or allergic dermatitis can be notified as occupational diseases. The two main prevention measures are reducing skin contact with irritants and complete avoidance of skin contact with offending allergens.
Paulsen, Evy; Andersen, Klaus E
2016-02-01
Lettuce (Lactuca sativa L.) and its varieties are important vegetable crops worldwide. They are also well-known, rarely reported, causes of contact allergy. As lettuce allergens and extracts are not commercially available, the allergy may be underdiagnosed. The aims of this article are to present new data on lettuce contact allergy and review the literature. Lettuce is weakly allergenic, and occupational cases are mainly reported. Using aimed patch testing in Compositae-allergic patients, two recent Danish studies showed prevalence rates of positive lettuce reactions of 11% and 22%. The majority of cases are non-occupational, and may partly be caused by cross-reactivity. The sesquiterpene lactone mix seems to be a poor screening agent for lettuce contact allergy, as the prevalence of positive reactions is significantly higher in non-occupationally sensitized patients. Because of the easy degradability of lettuce allergens, it is recommended to patch test with freshly cut lettuce stem and supplement this with Compositae mix. As contact urticaria and protein contact dermatitis may present as dermatitis, it is important to perform prick-to-prick tests, and possibly scratch patch tests as well. Any person who is occupationally exposed to lettuce for longer periods, especially atopics, amateur gardeners, and persons keeping lettuce-eating pets, is potentially at risk of developing lettuce contact allergy. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Mixed Lubricated Line Contacts
Faraon, I.C.
2005-01-01
The present work deals with friction in mixed lubricated line contacts. Components in systems are becoming smaller and due to, for instance power transmitted, partial contact may occur. In industrial applications, friction between the moving contacting surfaces cannot be avoided, therefore it is
New Cosmetic Contact Allergens
Directory of Open Access Journals (Sweden)
An Goossens
2015-02-01
Full Text Available Allergic and photo-allergic contact dermatitis, and immunologic contact urticaria are potential immune-mediated adverse effects from cosmetics. Fragrance components and preservatives are certainly the most frequently observed allergens; however, all ingredients must be considered when investigating for contact allergy.
Neutron spectra unfolding with maximum entropy and maximum likelihood
International Nuclear Information System (INIS)
Itoh, Shikoh; Tsunoda, Toshiharu
1989-01-01
A new unfolding theory has been established on the basis of the maximum entropy principle and the maximum likelihood method. This theory correctly embodies the Poisson statistics of neutron detection, and always brings a positive solution over the whole energy range. Moreover, the theory unifies both problems of overdetermined and of underdetermined. For the latter, the ambiguity in assigning a prior probability, i.e. the initial guess in the Bayesian sense, has become extinct by virtue of the principle. An approximate expression of the covariance matrix for the resultant spectra is also presented. An efficient algorithm to solve the nonlinear system, which appears in the present study, has been established. Results of computer simulation showed the effectiveness of the present theory. (author)
Maximum Power from a Solar Panel
Directory of Open Access Journals (Sweden)
Michael Miller
2010-01-01
Full Text Available Solar energy has become a promising alternative to conventional fossil fuel sources. Solar panels are used to collect solar radiation and convert it into electricity. One of the techniques used to maximize the effectiveness of this energy alternative is to maximize the power output of the solar collector. In this project the maximum power is calculated by determining the voltage and the current of maximum power. These quantities are determined by finding the maximum value for the equation for power using differentiation. After the maximum values are found for each time of day, each individual quantity, voltage of maximum power, current of maximum power, and maximum power is plotted as a function of the time of day.
International Nuclear Information System (INIS)
Kashan, M A M; Kalavally, V; Ramakrishnan, N; Lee, H W
2016-01-01
We report the characteristics and sensitivity dependence over the contact surface in coupled resonating sensors (CRSs) made of high aspect ratio resonant micropillars attached to a quartz crystal microbalance (QCM). Through experiments and simulation, we observed that when the pillars of resonant heights were placed in maximum displacement regions the resonance frequency of the QCM increased following the coupled resonance characteristics, as the pillar offered elastic loading to the QCM surface. However, the same pillars when placed in relatively lower displacement regions, in spite of their resonant dimension, offered inertial loading and resulted in a decrease in QCM resonance frequency, as the displacement amplitude was insufficient to couple the vibrations from the QCM to the pillars. Accordingly, we discovered that the coupled resonance characteristics not only depend on the resonant structure dimensions but also on the contact regions in the acoustic device. Further analysis revealed that acoustic pressure at the contact surface also influences the resonance frequency characteristics and sensitivity of the CRS. To demonstrate the significance of the present finding for sensing applications, humidity sensing is considered as the example measurand. When a sensing medium made of resonant SU-8 pillars was placed in a maximum displacement region on a QCM surface, the sensitivity increased by 14 times in comparison to a resonant sensing medium placed in a lower displacement region of a QCM surface. (paper)
Contact and symplectic topology
Colin, Vincent; Stipsicz, András
2014-01-01
Symplectic and contact geometry naturally emerged from the mathematical description of classical physics. The discovery of new rigidity phenomena and properties satisfied by these geometric structures launched a new research field worldwide. The intense activity of many European research groups in this field is reflected by the ESF Research Networking Programme "Contact And Symplectic Topology" (CAST). The lectures of the Summer School in Nantes (June 2011) and of the CAST Summer School in Budapest (July 2012) provide a nice panorama of many aspects of the present status of contact and symplectic topology. The notes of the minicourses offer a gentle introduction to topics which have developed in an amazing speed in the recent past. These topics include 3-dimensional and higher dimensional contact topology, Fukaya categories, asymptotically holomorphic methods in contact topology, bordered Floer homology, embedded contact homology, and flexibility results for Stein manifolds.
Cohen, Philip R
2014-01-01
Follicular contact dermatitis clinically presents as individual papules that include a central hair follicle. Pathologic features involve the follicle and the surrounding dermis: spongiosis and vesicle formation of the follicular epithelium associated with perifollicular and perivascular lymphocytic inflammation. Using the PubMed database, an extensive literature search was performed on follicular contact dermatitis and neomycin. Relevant papers were reviewed and the clinical and pathologic features, the associated chemicals (including a more detailed description of neomycin), the hypothesized pathogenesis, and the management of follicular contact dermatitis were described. Several agents-either as allergens or irritants-have been reported to elicit follicular contact dermatitis. Several hypotheses have been suggested for the selective involvement of the follicles in follicular contact dermatitis: patient allergenicity, characteristics of the agent, vehicle containing the agent, application of the agent, and external factors. The differential diagnosis of follicular contact dermatitis includes not only recurrent infundibulofolliculitis, but also drug eruption, mite infestation, viral infection, and dermatoses that affect hair follicles. The primary therapeutic intervention for follicular contact dermatitis is withdrawal of the causative agent; treatment with a topical corticosteroid preparation may also promote resolution of the dermatitis. In conclusion, follicular contact dermatitis may be secondary to allergens or irritants; topical antibiotics, including neomycin, may cause this condition. Several factors may account for the selective involvement of the hair follicle in this condition. Treatment of the dermatitis requires withdrawal of the associated topical agent; in addition, topical corticosteroids may be helpful to promote resolution of lesions. PMID:25516854
Contact materials for nanoelectronics
Alshareef, Husam N.
2011-02-01
In this article, we review current research activities in contact material development for electronic and nanoelectronic devices. A fundamental issue in contact materials research is to understand and control interfacial reactions and phenomena that modify the expected device performance. These reactions have become more challenging and more difficult to control as new materials have been introduced and as device sizes have entered the deep nanoscale. To provide an overview of this field of inquiry, this issue of MRS Bulletin includes articles on gate and contact materials for Si-based devices, junction contact materials for Si-based devices, and contact materials for alternate channel substrates (Ge and III-V), nanodevices. © 2011 Materials Research Society.
Contact Lens-Related Eye Infections
... Español Eye Health / Eye Health A-Z Contact Lens-Related Eye Infections Sections Contact Lens-Related Eye ... Six Steps to Avoid Contact Lens Infections Contact Lens-Related Eye Infections Leer en Español: Infecciones relacionadas ...
Directory of Open Access Journals (Sweden)
Nassear Rasheid Hmoad
2016-03-01
Full Text Available Among all the common mechanical transmission elements, gears still playing the most dominant role especially in the heavy duty works offering extraordinary performance under extreme conditions and that the cause behind the extensive researches concentrating on the enhancement of its durability to do its job as well as possible. Contact stress distribution within the teeth domain is considered as one of the most effective parameters characterizing gear life, performance, efficiency, and application so that it has been well sought for formal gear profiles and paid a lot of attention for moderate tooth shapes. The aim of this work is to investigate the effect of pressure angle, speed ratio, and correction factor on the maximum contact and bending stress value and principal stresses distribution for symmetric and asymmetric spur gear. The analytical investigation adopted Hertz equations to find the contact stress value, distribution, and the contact zone width while the numerical part depends on Ansys software version 15, as a FE solver with Lagrange and penalty contact algorithm. The most fruitful points to be noticed are that the increasing of pressure angle and speed ratio trends to minimize all the induced stresses for the classical gears and the altered teeth shape with larger loaded side pressure angle than the unloaded side one behave better than the symmetric teeth concerning the stress reduction.
Application of the maximum entropy production principle to electrical systems
International Nuclear Information System (INIS)
Christen, Thomas
2006-01-01
For a simple class of electrical systems, the principle of the maximum entropy production rate (MaxEP) is discussed. First, we compare the MaxEP principle and the principle of the minimum entropy production rate and illustrate the superiority of the MaxEP principle for the example of two parallel constant resistors. Secondly, we show that the Steenbeck principle for the electric arc as well as the ohmic contact behaviour of space-charge limited conductors follow from the MaxEP principle. In line with work by Dewar, the investigations seem to suggest that the MaxEP principle can also be applied to systems far from equilibrium, provided appropriate information is available that enters the constraints of the optimization problem. Finally, we apply the MaxEP principle to a mesoscopic system and show that the universal conductance quantum, e 2 /h, of a one-dimensional ballistic conductor can be estimated
Are diverse societies less cohesive? Testing contact and mediated contact theories.
McKenna, Sarah; Lee, Eunro; Klik, Kathleen A; Markus, Andrew; Hewstone, Miles; Reynolds, Katherine J
2018-01-01
Previous research has demonstrated that there is a negative relationship between ethnic diversity in a local community and social cohesion. Often the way social cohesion is assessed, though, varies across studies and only some aspects of the construct are included (e.g., trust). The current research explores the relationship between diversity and social cohesion across a number of indicators of social cohesion including neighbourhood social capital, safety, belonging, generalized trust, and volunteering. Furthermore, social psychological theories concerning the role of positive contact and its impact on feelings of threat are investigated. Using a sample of 1070 third generation 'majority' Australians and structural equation modelling (SEM), findings suggest ethnic diversity is related to positive intergroup contact, and that contact showed beneficial impacts for some indicators of social cohesion both directly and indirectly through reducing perceived threat. When interethnic contact and perceived threat are included in the model there is no direct negative effect between diversity and social cohesion. The theoretical implications of these findings are outlined including the importance of facilitating opportunities for positive contact in diverse communities.
Focusing on Contact Lens Safety
... their practices. Decorative contacts (also called “costume,” colored,” “fashion,” or “plano” contacts). The FDA has often warned ... Lenses Decorative Contact Lenses Hydrogen Peroxide Solution Related Consumer Updates 'Colored' and Decorative Contact Lenses: A Prescription ...
Contact-impact algorithms on parallel computers
International Nuclear Information System (INIS)
Zhong Zhihua; Nilsson, Larsgunnar
1994-01-01
Contact-impact algorithms on parallel computers are discussed within the context of explicit finite element analysis. The algorithms concerned include a contact searching algorithm and an algorithm for contact force calculations. The contact searching algorithm is based on the territory concept of the general HITA algorithm. However, no distinction is made between different contact bodies, or between different contact surfaces. All contact segments from contact boundaries are taken as a single set. Hierarchy territories and contact territories are expanded. A three-dimensional bucket sort algorithm is used to sort contact nodes. The defence node algorithm is used in the calculation of contact forces. Both the contact searching algorithm and the defence node algorithm are implemented on the connection machine CM-200. The performance of the algorithms is examined under different circumstances, and numerical results are presented. ((orig.))
Qaisi, Ramy M.; Smith, Casey; Ghoneim, Mohamed T.; Yu, Qingkai; Hussain, Muhammad Mustafa
2013-01-01
We demonstrate a buried contact based novel test structure for direct contact resistivity measurement of graphene-metal interfaces. We also observe excellent contact resistivity 1 μO-cm2 without any additional surface modification suggesting that the intrinsic Au-graphene contact is sufficient for achieving devices with low contact resistance. The chemical mechanical polishing less test structure and data described herein highlights an ideal methodology for systematic screening and engineering of graphene-metal contact resistivity to enable low power high speed carbon electronics. © 2013 IEEE.
Qaisi, Ramy M.
2013-08-01
We demonstrate a buried contact based novel test structure for direct contact resistivity measurement of graphene-metal interfaces. We also observe excellent contact resistivity 1 μO-cm2 without any additional surface modification suggesting that the intrinsic Au-graphene contact is sufficient for achieving devices with low contact resistance. The chemical mechanical polishing less test structure and data described herein highlights an ideal methodology for systematic screening and engineering of graphene-metal contact resistivity to enable low power high speed carbon electronics. © 2013 IEEE.
Bordel-Gómez, Ma T; Miranda-Romero, A; Castrodeza-Sanz, J
2010-01-01
general. Women became sensitized at a younger age than men, and the frequency of positive results in the patch tests increased with age, reaching a maximum at between 60 and 69 years of age, when the greatest rate of sensitization occurred. Comparison of our results with other Spanish data showed a progressive and constant increase in sensitization to nickel sulfate, fragrance blends, balsam of Peru, and rosin, and a decrease in sensitization to potassium dichromate. The inclusion of new allergens such as palladium chloride, diallyl disulfide, and p-toluene sulfonamide formaldehyde improved the sensitivity of the standard battery in the detection of contact sensitization. We therefore recommend further studies of these allergens.
Hydrogenation of passivated contacts
Energy Technology Data Exchange (ETDEWEB)
Nemeth, William; Yuan, Hao-Chih; LaSalvia, Vincenzo; Stradins, Pauls; Page, Matthew R.
2018-03-06
Methods of hydrogenation of passivated contacts using materials having hydrogen impurities are provided. An example method includes applying, to a passivated contact, a layer of a material, the material containing hydrogen impurities. The method further includes subsequently annealing the material and subsequently removing the material from the passivated contact.
Mathematical Modeling of Contact Problems of Elasticity Theory with Continuous Unilateral Contact
Directory of Open Access Journals (Sweden)
I. V. Stankevich
2015-01-01
Full Text Available The work [1] presents the formulation and numerical solution of the problem concerning the unilateral discrete contact interaction of an elastic body and a rigid half-space. However, many parts and components of engineering structures have a pronounced continuous contact within a given surface [2, 3]. In this paper we consider a special case of this option of contact interaction when, the elastic body of finite size, subjected to external forces, is based on a rigid half-space. Contact occurs through a dedicated contact surface, which in general can change their sizes.Developed to solve this problem, a numerical algorithm is a further adaptation and development of the approaches described in [1]. The paper shows results of solving the model problem of the elasticity theory with and without taking friction into account. In the latter case, were additionally obtained numerical data characterizing the convergence of the solution.
DEFF Research Database (Denmark)
Paulsen, Evy; Christensen, Lars P; Andersen, Klaus Ejner
2012-01-01
The tomato plant (Solanum lycopersicum) is an important crop worldwide. Whereas immediate-type reactions to tomato fruits are well known, contact dermatitis caused by tomatoes or tomato plants is rarely reported. The aims of this study were to present new data on contact sensitization to tomato...... plants and review the literature on contact dermatitis caused by both plants and fruits. An ether extract of tomato plants made as the original oleoresin plant extracts, was used in aimed patch testing, and between 2005 and 2011. 8 of 93 patients (9%) tested positive to the oleoresin extracts....... This prevalence is in accordance with the older literature that reports tomato plants as occasional sensitizers. The same applies to tomato fruits, which, in addition, may cause protein contact dermatitis. The allergens of the plant are unknown, but both heat-stable and heat-labile constituents seem...
Comparing the occlusal contact area of individual teeth during low-level clenching.
Nishimori, Hideta; Iida, Takashi; Kamiyama, Hirona; Komoda, Yoshihiro; Obara, Ryoko; Uchida, Takashi; Kawara, Misao; Komiyama, Osamu
2017-09-14
The aim of this study was to investigate the occlusal contact area (OCA) in individual teeth during low-level tooth clenching in 24 healthy participants. Before measurements were made, the 100% maximum voluntary contraction (MVC) was determined. At baseline, all subjects were instructed to close their mouth and touch the opposing teeth with minimal force. Occlusal contact was recorded during three jaw motor tasks (baseline, 20% MVC, and 40% MVC) using a blue silicone material. OCA thickness was determined from images and defined on five levels: level 1 (0-149 µm), level 2 (0-89 µm), level 3 (0-49 µm), level 4 (0-29 µm), and level 5 (0-4 µm). Premolar and molar OCAs increased significantly from baseline to 20% MVC and 40% MVC. The OCA of each anterior tooth did not change significantly with increasing clenching intensity at all levels. Our findings suggest that premolar and molar OCAs may be altered by low-intensity clenching, affecting the teeth and periodontal tissues.
The Physical Effects of Contact and Close-Distance Gunfire on Sweatshirt Fleece.
Kusluski, Michael A
2018-05-01
Powder stippling caused by the impact of propellant particles during close-distance gunfire has been previously described on skin and solid objects only. Additionally, radial tearing has been described as clear evidence of a contact-distance shot, requiring no further testing. Patterns of discrete perforating holes (referred to here as "stippling perforations") and other physical damage on sweatshirt fleece fabrics were prepared. Using the firearm and ammunition in this study, stippling perforations were observed to a maximum muzzle-to-target distance of 35 cm (10 inches). In addition, radial tearing and disintegration were present (and often more extensive) at greater than contact distance. The presence of stippling perforations could augment muzzle-to-target distance estimates generated using the Griess test, or allow distance estimates when the Griess test is not feasible. Unlike what has been previously reported, testing on the original evidence (or similar substitute) is warranted when physical damage is used to estimate shooting distance. © 2017 American Academy of Forensic Sciences.
International Nuclear Information System (INIS)
Tove, P.A.
1975-08-01
Contacts to semiconductors play an important role in most semiconductor devices. These devices range from microelectronics to power components, from high-sensitivity light or radiation detectors to light-emitting of microwave-generating components. Silicon is the dominating material but compound semiconductors are increasing in importance. The following survey is an attempt to classify contact properties and the physical mechanisms involved, as well as fabrication methods and methods of investigation. The main interest is in metal-semiconductor type contacts where a few basic concepts are dealt with in some detail. (Auth.)
Contact sensitization and allergic contact dermatitis in patients with eczematous lesions
Directory of Open Access Journals (Sweden)
Perpetua U Ibekwe
2018-01-01
Conclusions: Most ACD patients showed contact sensitization to leather products, metal, and perfume use. This knowledge is important when considering preventive measures. However, further studies are needed to provide more insight into contact allergy in Nigeria.
EFFECTS OF A SAND RUNNING SURFACE ON THE KINEMATICS OF SPRINTING AT MAXIMUM VELOCITY
Directory of Open Access Journals (Sweden)
P E Alcaraz
2011-05-01
Full Text Available Performing sprints on a sand surface is a common training method for improving sprint-specific strength. For maximum specificity of training the athlete’s movement patterns during the training exercise should closely resemble those used when performing the sport. The aim of this study was to compare the kinematics of sprinting at maximum velocity on a dry sand surface to the kinematics of sprinting on an athletics track. Five men and five women participated in the study, and flying sprints over 30 m were recorded by video and digitized using biomechanical analysis software. We found that sprinting on a sand surface was substantially different to sprinting on an athletics track. When sprinting on sand the athletes tended to ‘sit’ during the ground contact phase of the stride. This action was characterized by a lower centre of mass, a greater forward lean in the trunk, and an incomplete extension of the hip joint at take-off. We conclude that sprinting on a dry sand surface may not be an appropriate method for training the maximum velocity phase in sprinting. Although this training method exerts a substantial overload on the athlete, as indicated by reductions in running velocity and stride length, it also induces detrimental changes to the athlete’s running technique which may transfer to competition sprinting.
Fabricating customized hydrogel contact lens
Childs, Andre; Li, Hao; Lewittes, Daniella M.; Dong, Biqin; Liu, Wenzhong; Shu, Xiao; Sun, Cheng; Zhang, Hao F.
2016-10-01
Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fabricated hydrogel is highly transparent, with refractive indices ranging from 1.42 to 1.45 in the spectra range from 400 nm to 800 nm. The Young’s modulus (1.47 MPa) and hydrophobicity (with a sessile drop contact angle of 40.5°) have also been characterized experimentally. Retinal imaging using optical coherence tomography in rats wearing our customized contact lenses has the quality comparable to the control case without the contact lens. Our method could significantly reduce the cost and the lead time for fabricating soft contact lenses with customized shapes, and benefit the laboratorial-used contact lenses in pre-clinical studies.
Intercellular contact: its influence on the Dsub(q) of mammalian cell survival curves
International Nuclear Information System (INIS)
Durand, R.E.; Sutherland, R.M.
1975-01-01
Cell survival in tissues exposed to a given dose of ionizing radiation is usually greater than that of similar cells grown individually in vitro, despite the fact that the radiosensitivities (D 0 ) are virtually identical under the two conditions. An analogous increase in cell survival is observed when Chinese hamster V79-171 cells are grown in suspension culture and irradiated as multicell spheroids. Unfortunately, the information gained from the survival curves so obtained is limited by the inhomogeneity of the cell population with respect to both degree of contact and cell cycle position. The latter can be studied using synchronized small spheroids. The ratio of Dsub(q) of spheroid cells to Dsub(q) of single cells increased as the cells progressed through the cell cycle, from a minimum of 1.3 for G 1 phase cells to a maximum of 2.2 for late S-phase cells. The enhanced survival, or 'contact effect', developed slowly as the spheroids grew, after an initial latent period of about one generation cycle of the cells. A second effect of intercellular contact on mammalian cell survival has also been observed. When cells are assayed under conditions in which intercellular contact is maintained, the net cellular survival is increased further. This effect is different from the usual repair of potentially lethal damage, in that it occurs much more slowly and results in modification of the survival-curve shoulder. Not all cell types tested have shown enhanced survival when grown as spheroids. Several MNNG-induced mutants of the Chinese hamster V79-171 line have been isolated and sublines which do and do not show the contact effect are now available. These may permit study of the mechanism(s) of contact effects. (author)
Experiences of offspring searching for and contacting their donor siblings and donor.
Jadva, Vasanti; Freeman, Tabitha; Kramer, Wendy; Golombok, Susan
2010-04-01
This study investigates a new phenomenon whereby individuals conceived by donor insemination are searching for and contacting their donor and/or 'donor siblings' (i.e. donor offspring conceived by the same donor who are their genetic half siblings). On-line questionnaires were completed by members of the Donor Sibling Registry (DSR), a US-based registry that facilitates contact between donor conception families who share the same donor. Of the 165 donor offspring who completed the survey, 15% were searching for their donor siblings, 13% were searching for their donor, and 64% were searching for both. Differences were found according to family type and age of disclosure. Fewer offspring from heterosexual couple families had told their father about their search when compared with offspring from lesbian couple families who had told their co-parent. Offspring who had found out about their conception after age 18 were more likely to be searching for medical reasons, whereas those who had found out before age 18 tended to be searching out of curiosity. Some offspring had discovered large numbers of half siblings (maximum=13). The majority of offspring who had found their donor relations reported positive experiences and remained in regular contact with them. Copyright (c) 2010 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.
Frequency shift and hysteresis suppression in contact-mode AFM using contact stiffness modulation
Directory of Open Access Journals (Sweden)
Belhaq M.
2012-07-01
Full Text Available In this paper the frequency response shift and hysteresis suppression of contact-mode atomic force microscopy is investigated using parametric modulation of the contact stiffness. Based on the Hertzian contact theory, a lumped single degree of freedom oscillator is considered for modeling the cantilever dynamics contact-mode atomic force microscopy. We use the technique of direct partition of motion and the method of multiple scales to obtain, respectively, the slow dynamic and the corresponding slow flow of the system. As results, this study shows that the amplitude of the contact stiffness modulation has a significant effect on the frequency response. Specifically, increasing the amplitude of the stiffness modulation suppresses hysteresis, decreases the peak amplitude and produces shifts towards higher and lower frequencies.
2013-05-22
...] National Contact Center; Submission for OMB Review; National Contact Center Customer Evaluation Survey... regarding the National Contact Center customer evaluation surveys. In this request, the previously approved... customer service levels to those of private industry contact centers. A notice was published in the Federal...
DEFF Research Database (Denmark)
Alberti, Mark; la Cour, Morten
2018-01-01
PURPOSE: To compare gas-foveal contact in face-down positioning (FDP) and nonsupine positioning (NSP), to analyze causes of gas-foveal separation and to determine how gas-foveal contact affects clinical outcome after idiopathic macular hole repair. METHODS: Single center, randomized controlled...... study. Participants with an idiopathic macular hole were allocated to either FDP or NSP. Primary outcome was gas-foveal contact, calculated by analyzing positioning in relation to intraocular gas fill. Positioning was measured with an electronic device recording positioning for 72 hours postoperatively....... RESULTS: Positioning data were available for 33/35 in the FDP group and 35/37 in the NSP group, thus results are based on 68 analyzed participants. Median gas-foveal contact was 99.82% (range 73.6-100.0) in the FDP group and 99.57% (range 85.3-100.0) in the NSP group (P = 0.22). In a statistical model...
Kreiss, Gunilla; Holmgren, Hanna; Kronbichler, Martin; Ge, Anthony; Brant, Luca
2017-11-01
The conventional no-slip boundary condition leads to a non-integrable stress singularity at a moving contact line. This makes numerical simulations of two-phase flow challenging, especially when capillarity of the contact point is essential for the dynamics of the flow. We will describe a modeling methodology, which is suitable for numerical simulations, and present results from numerical computations. The methodology is based on combining a relation between the apparent contact angle and the contact line velocity, with the similarity solution for Stokes flow at a planar interface. The relation between angle and velocity can be determined by theoretical arguments, or from simulations using a more detailed model. In our approach we have used results from phase field simulations in a small domain, but using a molecular dynamics model should also be possible. In both cases more physics is included and the stress singularity is removed.
Mathematical Modeling of Contact Problems of Elasticity Theory with Unilateral Discrete Contact
Directory of Open Access Journals (Sweden)
I. V. Stankevich
2015-01-01
Full Text Available Development and operation of modern machinery and latest technology require reliable estimates of the strength characteristics of the critical elements of structures and technological equipment under the impact of high-intensity thermomechanical loading, accompanied, as a rule, by complex contact interaction. Mathematical modeling of stress-strain state of such parts and components in the contact area, based on adequate mathematical models, modern numerical methods and efficient algorithms that implement the direct determination of displacement fields, strains and stresses, is the main tool that allows fast acquisition of data required for the calculations of strength and durability. The paper considers an algorithm for constructing the numerical solution of the contact problem of elasticity theory in relation to the body, which has an obvious one-sided discrete contact interaction with an elastic half-space. The proposed algorithm is specially designed to have a correction of the tangential forces at discrete contact points, allowing us to achieve sufficiently accurate implementation of the adopted law of friction. The algorithm is embedded in a general finite element technology, with which the application code is generated. Numerical study of discrete unilateral contact interaction of an elastic plate and a rigid half-space showed a high efficiency of the developed algorithm and the application code that implements it.
Non-contact ultrasound techniques
International Nuclear Information System (INIS)
Khazali Mohd Zin
2001-01-01
Non-contact ultrasound plays significant role in material characterisation and inspection. Unlike conventional ultrasonic techniques, non-contact ultrasonic is mostly applicable to areas where the former has its weaknesses and limitations. It is interesting to note that the non-contact ultrasonic technique has an important significant application in industry. The technique is signified by the fact that the object to be inspected is further away from the ultrasonic source, no couplant is needed and inconsistent pressure between the transducer and the specimen can be eliminated. The paper discusses some of the non-contact ultrasound technique and its applications. (Author)
Colors and contact dermatitis.
Bonamonte, Domenico; Foti, Caterina; Romita, Paolo; Vestita, Michelangelo; Angelini, Gianni
2014-01-01
The diagnosis of skin diseases relies on several clinical signs, among which color is of paramount importance. In this review, we consider certain clinical presentations of both eczematous and noneczematous contact dermatitis in which color plays a peculiar role orientating toward the right diagnosis. The conditions that will be discussed include specific clinical-morphologic subtypes of eczematous contact dermatitis, primary melanocytic, and nonmelanocytic contact hyperchromia, black dermographism, contact chemical leukoderma, and others. Based on the physical, chemical, and biologic factors underlying a healthy skin color, the various skin shades drawing a disease picture are thoroughly debated, stressing their etiopathogenic origins and histopathologic aspects.
The importance of contact quality
DEFF Research Database (Denmark)
van Bakel, Marian; Gerritsen, Marinel; van Oudenhoven, Jan Pieter
Establishing contact between expatriates and a local host has been found to reap benefits with regard to Interaction Adjustment, Host National Social Support, Open-mindedness, and Social Initiative. This longitudinal study examines the role of the quality of contact for these four aspects....... Expatriates in the Netherlands were randomly divided into an experimental group (n = 33) of which 21 developed high-quality contact with their host, and a control group (n = 32) without host. The results show that contact quality plays an important role and suggest that the higher the quality of the contact......, the more benefit the expatriate experienced. Moreover, expatriates with low-quality contact did not experience a detrimental effect....
FreeContact: fast and free software for protein contact prediction from residue co-evolution.
Kaján, László; Hopf, Thomas A; Kalaš, Matúš; Marks, Debora S; Rost, Burkhard
2014-03-26
20 years of improved technology and growing sequences now renders residue-residue contact constraints in large protein families through correlated mutations accurate enough to drive de novo predictions of protein three-dimensional structure. The method EVfold broke new ground using mean-field Direct Coupling Analysis (EVfold-mfDCA); the method PSICOV applied a related concept by estimating a sparse inverse covariance matrix. Both methods (EVfold-mfDCA and PSICOV) are publicly available, but both require too much CPU time for interactive applications. On top, EVfold-mfDCA depends on proprietary software. Here, we present FreeContact, a fast, open source implementation of EVfold-mfDCA and PSICOV. On a test set of 140 proteins, FreeContact was almost eight times faster than PSICOV without decreasing prediction performance. The EVfold-mfDCA implementation of FreeContact was over 220 times faster than PSICOV with negligible performance decrease. EVfold-mfDCA was unavailable for testing due to its dependency on proprietary software. FreeContact is implemented as the free C++ library "libfreecontact", complete with command line tool "freecontact", as well as Perl and Python modules. All components are available as Debian packages. FreeContact supports the BioXSD format for interoperability. FreeContact provides the opportunity to compute reliable contact predictions in any environment (desktop or cloud).
International Nuclear Information System (INIS)
1991-01-01
The meaning of the term 'maximum concentration at work' in regard of various pollutants is discussed. Specifically, a number of dusts and smokes are dealt with. The valuation criteria for maximum biologically tolerable concentrations for working materials are indicated. The working materials in question are corcinogeneous substances or substances liable to cause allergies or mutate the genome. (VT) [de
PREFACE: Non-contact AFM Non-contact AFM
Giessibl, Franz J.; Morita, Seizo
2012-02-01
This special issue is focussed on high resolution non-contact atomic force microscopy (AFM). Non-contact atomic force microscopy was established approximately 15 years ago as a tool to image conducting and insulating surfaces with atomic resolution. Since 1998, an annual international conference has taken place, and although the proceedings of these conferences are a useful source of information, several key developments warrant devoting a special issue to this subject. In the theoretic field, the possibility of supplementing established techniques such as scanning tunneling microscopy (STM) and Kelvin probe microscopy with atomically resolved force micrsoscopy poses many challenges in the calculation of contrast and contrast reversal. The surface science of insulators, self-assembled monolayers and adsorbates on insulators is a fruitful field for the application of non-contact AFM: several articles in this issue are devoted to these subjects. Atomic imaging and manipulation have been pioneered using STM, but because AFM allows the measurement of forces, AFM has had a profound impact in this field as well. Three-dimensional force spectroscopy has allowed many important insights into surface science. In this issue a combined 3D tunneling and force microscopy is introduced. Non-contact AFM typically uses frequency modulation to measure force gradients and was initially used mainly in a vacuum. As can be seen in this issue, frequency modulation is now also used in ambient conditions, allowing better spatial and force resolution. We thank all of the contributors for their time and efforts in making this special issue possible. We are also very grateful to the staff of IOP Publishing for handling the administrative aspects and for steering the refereeing process. Non-contact AFM contents Relation between the chemical force and the tunnelling current in atomic point contacts: a simple model Pavel Jelínek, Martin Ondrácek and Fernando Flores Theoretical simulation of
DEFF Research Database (Denmark)
Paulsen, Evy; Andersen, Klaus E
2016-01-01
Lettuce (Lactuca sativa L.) and its varieties are important vegetable crops worldwide. They are also well-known, rarely reported, causes of contact allergy. As lettuce allergens and extracts are not commercially available, the allergy may be underdiagnosed. The aims of this article are to present...... person who is occupationally exposed to lettuce for longer periods, especially atopics, amateur gardeners, and persons keeping lettuce-eating pets, is potentially at risk of developing lettuce contact allergy.......Lettuce (Lactuca sativa L.) and its varieties are important vegetable crops worldwide. They are also well-known, rarely reported, causes of contact allergy. As lettuce allergens and extracts are not commercially available, the allergy may be underdiagnosed. The aims of this article are to present...... new data on lettuce contact allergy and review the literature. Lettuce is weakly allergenic, and occupational cases are mainly reported. Using aimed patch testing in Compositae-allergic patients, two recent Danish studies showed prevalence rates of positive lettuce reactions of 11% and 22...
2010-07-01
... cylinders having an internal diameter of 13.0 cm and a 15.5 cm stroke length, the rounded displacement would... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Maximum engine power, displacement... Maximum engine power, displacement, power density, and maximum in-use engine speed. This section describes...
International Nuclear Information System (INIS)
Basu, A; Adams, G G; McGruer, N E
2016-01-01
Direct contact, ohmic MEMS switches for RF applications have several advantages over other conventional switching devices. Advantages include lower insertion loss, higher isolation, and better switching figure-of-merit (cut-off frequency). The most important aspect of a direct-contact RF MEMS switch is the metal microcontact which can dictate the lifetime and reliability of the switch. Therefore, an understanding of contact reliability is essential for developing robust MEMS switches. This paper discusses and reviews the most important work done over the past couple of decades toward understanding ohmic micro-contacts. We initially discuss the contact mechanics and multi-physics models for studying Hertzian and multi-asperity contacts. We follow this with a discussion on models and experiments for studying adhesion. We then discuss experimental setups and the development of contact test stations by various groups for accelerated testing of microcontacts, as well as for analysis of contact reliability issues. Subsequently, we analyze a number of material transfer mechanisms in microcontacts under hot and cold switching conditions. We finally review the material properties that can help determine the selection of contact materials. A trade-off between contact resistance and high reliability is almost always necessary during selection of contact material; this paper discusses how the choice of materials can help address such trade-offs. (paper)
Credal Networks under Maximum Entropy
Lukasiewicz, Thomas
2013-01-01
We apply the principle of maximum entropy to select a unique joint probability distribution from the set of all joint probability distributions specified by a credal network. In detail, we start by showing that the unique joint distribution of a Bayesian tree coincides with the maximum entropy model of its conditional distributions. This result, however, does not hold anymore for general Bayesian networks. We thus present a new kind of maximum entropy models, which are computed sequentially. ...
Czech Academy of Sciences Publication Activity Database
Voca, S.; Graf, Sylvie
2018-01-01
Roč. 12, č. 1 (2018), s. 47-57 ISSN 2309-3455 R&D Projects: GA ČR(CZ) GA17-14387S Institutional support: RVO:68081740 Keywords : positive intergroup contact * negative intergroup contact * extended intergroup contact * mass-mediated intergroup contact * willingness to engage in intergroup contact * empathy * outgroup trust Subject RIV: AN - Psychology OBOR OECD: Psychology (including human - machine relations)
Effect of contact deformation on contact electrification: a first-principles calculation
International Nuclear Information System (INIS)
Zhang, Yuanyue; Shao, Tianmin
2013-01-01
The effect of contact deformation on contact electrification of metallic materials was studied by the first-principles method. The results of charge population and the densities of states of the deformed contact models demonstrated that the magnitude of the transferred charge increased with deformation. The mechanism of the effect of deformation was investigated by studying the electronic properties of the deformed surface slabs. The results showed that crystal deformation led to a change in the electrostatic potential of the metal, where the number of nearly free electrons and unoccupied orbitals for charge transfer increased, and their energy barrier decreased. (paper)
International Nuclear Information System (INIS)
Di Bartolomeo, A; Giubileo, F; Iemmo, L; Romeo, F; Santandrea, S; Gambardella, U
2013-01-01
We produced graphene-based field-effect transistors by contacting mono- and bi-layer graphene by sputtering Ni or Ti as metal electrodes. We performed electrical characterization of the devices by measuring their transfer and output characteristics. We clearly observed the presence of a double-dip feature in the conductance curve for Ni-contacted transistors, and we explain it in terms of charge transfer and graphene doping under the metal contacts. We also studied the contact resistance between the graphene and the metal electrodes with larger values of ∼30 kΩμm 2 recorded for Ti contacts. Importantly, we prove that the contact resistance is modulated by the back-gate voltage. (paper)
Maximum Entropy in Drug Discovery
Directory of Open Access Journals (Sweden)
Chih-Yuan Tseng
2014-07-01
Full Text Available Drug discovery applies multidisciplinary approaches either experimentally, computationally or both ways to identify lead compounds to treat various diseases. While conventional approaches have yielded many US Food and Drug Administration (FDA-approved drugs, researchers continue investigating and designing better approaches to increase the success rate in the discovery process. In this article, we provide an overview of the current strategies and point out where and how the method of maximum entropy has been introduced in this area. The maximum entropy principle has its root in thermodynamics, yet since Jaynes’ pioneering work in the 1950s, the maximum entropy principle has not only been used as a physics law, but also as a reasoning tool that allows us to process information in hand with the least bias. Its applicability in various disciplines has been abundantly demonstrated. We give several examples of applications of maximum entropy in different stages of drug discovery. Finally, we discuss a promising new direction in drug discovery that is likely to hinge on the ways of utilizing maximum entropy.
African Journals Online (AJOL)
Principal Contact. Ehouan Etienne Ehile Professor University of Abobo-Adjamé 02 BP 801 Abidjan 02. Phone: (+225) 2030 4201. Fax: (+225) 2030 4203. Email: eh_ehile@yahoo.fr. Support Contact. Irie Zoro Bi Email: banhiakalou@yahoo.fr. ISSN: 1812-0741. AJOL African Journals Online. HOW TO USE AJOL.
Low temperature deposition of bifacial CIGS solar cells on Al-doped Zinc Oxide back contacts
Energy Technology Data Exchange (ETDEWEB)
Cavallari, Nicholas, E-mail: nicholas.cavallari@imem.cnr.it [IMEM-CNR, Parco Area delle Scienze 37/a, 43124 Parma (Italy); Department of Mathematical, Physical and Computer Sciences, University of Parma, Parco Area delle Scienze 7/a, 43124 Parma (Italy); Pattini, Francesco; Rampino, Stefano; Annoni, Filippo [IMEM-CNR, Parco Area delle Scienze 37/a, 43124 Parma (Italy); Barozzi, Mario [FBK—CMM—Micro Nano Facility, Via Sommarive 18, 38123 Trento (Italy); Bronzoni, Matteo; Gilioli, Edmondo; Gombia, Enos [IMEM-CNR, Parco Area delle Scienze 37/a, 43124 Parma (Italy); Maragliano, Carlo [Solar Bankers LLC, Phoenix, AZ (United States); Mazzer, Massimo [IMEM-CNR, Parco Area delle Scienze 37/a, 43124 Parma (Italy); Pepponi, Giancarlo [FBK—CMM—Micro Nano Facility, Via Sommarive 18, 38123 Trento (Italy); Spaggiari, Giulia; Fornari, Roberto [IMEM-CNR, Parco Area delle Scienze 37/a, 43124 Parma (Italy); Department of Mathematical, Physical and Computer Sciences, University of Parma, Parco Area delle Scienze 7/a, 43124 Parma (Italy)
2017-08-01
Highlights: • AZO and CIGS were deposited by Low-Temperature Pulsed Electron Deposition (LT-PED). • CIGS/AZO contacts with ohmic behavior and resistance of 1.07 Ω cm{sup 2} were fabricated. • LT-PED deposition of AZO and CIGS prevents formation of Ga{sub 2}O{sub 3} interlayer. • CIGS-based bifacial solar cells with AZO back contact were realized. • Front PV efficiency of 9.3% and equivalent bifacial efficiency of 11.6% were achieved. - Abstract: We report on the fabrication and characterization of Cu(In,Ga)Se{sub 2} (CIGS)-based thin film bifacial solar cells using Al-doped ZnO (AZO) as cost-effective and non-toxic transparent back contact. We show that, by depositing both CIGS and AZO by Low Temperature Pulsed Electron Deposition at a maximum temperature of 250 °C, a good ohmic contact is formed between the two layers and good quality solar cells can be fabricated as a result. Photovoltaic efficiencies as high as 9.3% (front illumination), 5.1% (backside illumination) and 11.6% (bifacial illumination) have been obtained so far. These values are remarkably higher than those previously reported in the literature. We demonstrate that this improvement is ascribed to the low-temperature deposition process that avoids the formation of Ga{sub 2}O{sub 3} at the CIGS/AZO interface and favours the formation of a low-resistivity contact in agreement with device simulations.
Vakis, Antonis I.; Polycarpou, Andreas A.
2010-06-01
In the effort to achieve Tbit/inch2 recording densities, thermal fly-height control (TFC) nanotechnology was developed to effectively reduce the clearance (which is of the order of a few nanometres) at the head-disk interface (HDI) of hard-disk drives. In this work, we present a model of the HDI that can predict the dynamic flying and nanotribological contacting behaviour, allowing for accurate predictions and characterization of the operating regime as a function of TFC actuation. A geometric model for TFC is presented and an improved definition of contact at the interface is developed in the presence of nanoscale topographical roughness and dynamic microwaviness. A new methodology is proposed for the calculation of the nominal area of contact, which affects both near- and at-contact behaviour, while the stiffening of the air bearing force with TFC actuation is also accounted for. Slider behaviour is analysed by quantifying the approach, jump-to-contact, lubricant and solid contact regimes of operation and identifying the critical and optimum TFC actuations. The feasibility of near-contact, light molecularly thin lubricant contact versus solid contact recording is explored under the effect of the interfacial forces and stresses present at the HDI. The clearance and the state of vibrations are analysed and design guidelines are proposed for improved performance.
International Nuclear Information System (INIS)
Vakis, Antonis I; Polycarpou, Andreas A
2010-01-01
In the effort to achieve Tbit/inch 2 recording densities, thermal fly-height control (TFC) nanotechnology was developed to effectively reduce the clearance (which is of the order of a few nanometres) at the head-disk interface (HDI) of hard-disk drives. In this work, we present a model of the HDI that can predict the dynamic flying and nanotribological contacting behaviour, allowing for accurate predictions and characterization of the operating regime as a function of TFC actuation. A geometric model for TFC is presented and an improved definition of contact at the interface is developed in the presence of nanoscale topographical roughness and dynamic microwaviness. A new methodology is proposed for the calculation of the nominal area of contact, which affects both near- and at-contact behaviour, while the stiffening of the air bearing force with TFC actuation is also accounted for. Slider behaviour is analysed by quantifying the approach, jump-to-contact, lubricant and solid contact regimes of operation and identifying the critical and optimum TFC actuations. The feasibility of near-contact, light molecularly thin lubricant contact versus solid contact recording is explored under the effect of the interfacial forces and stresses present at the HDI. The clearance and the state of vibrations are analysed and design guidelines are proposed for improved performance.
Maximum Quantum Entropy Method
Sim, Jae-Hoon; Han, Myung Joon
2018-01-01
Maximum entropy method for analytic continuation is extended by introducing quantum relative entropy. This new method is formulated in terms of matrix-valued functions and therefore invariant under arbitrary unitary transformation of input matrix. As a result, the continuation of off-diagonal elements becomes straightforward. Without introducing any further ambiguity, the Bayesian probabilistic interpretation is maintained just as in the conventional maximum entropy method. The applications o...
deGroh, Kim; Berger, Lauren; Roberts, Lily
2009-01-01
The purpose of this study was to determine the effect of atomic oxygen (AO) exposure on the hydrophilicity of nine different polymers for biomedical applications. Atomic oxygen treatment can alter the chemistry and morphology of polymer surfaces, which may increase the adhesion and spreading of cells on Petri dishes and enhance implant growth. Therefore, nine different polymers were exposed to atomic oxygen and water-contact angle, or hydrophilicity, was measured after exposure. To determine whether hydrophilicity remains static after initial atomic oxygen exposure, or changes with higher fluence exposures, the contact angles between the polymer and water droplet placed on the polymer s surface were measured versus AO fluence. The polymers were exposed to atomic oxygen in a 100-W, 13.56-MHz radio frequency (RF) plasma asher, and the treatment was found to significantly alter the hydrophilicity of non-fluorinated polymers. Pristine samples were compared with samples that had been exposed to AO at various fluence levels. Minimum and maximum fluences for the ashing trials were set based on the effective AO erosion of a Kapton witness coupon in the asher. The time intervals for ashing were determined by finding the logarithmic values of the minimum and maximum fluences. The difference of these two values was divided by the desired number of intervals (ideally 10). The initial desired fluence was then multiplied by this result (2.37), as was each subsequent desired fluence. The flux in the asher was determined to be approximately 3.0 x 10(exp 15) atoms/sq cm/sec, and each polymer was exposed to a maximum fluence of 5.16 x 10(exp 20) atoms/sq cm.
Elastic contact mechanics: percolation of the contact area and fluid squeeze-out.
Persson, B N J; Prodanov, N; Krick, B A; Rodriguez, N; Mulakaluri, N; Sawyer, W G; Mangiagalli, P
2012-01-01
The dynamics of fluid flow at the interface between elastic solids with rough surfaces depends sensitively on the area of real contact, in particular close to the percolation threshold, where an irregular network of narrow flow channels prevails. In this paper, numerical simulation and experimental results for the contact between elastic solids with isotropic and anisotropic surface roughness are compared with the predictions of a theory based on the Persson contact mechanics theory and the Bruggeman effective medium theory. The theory predictions are in good agreement with the experimental and numerical simulation results and the (small) deviation can be understood as a finite-size effect. The fluid squeeze-out at the interface between elastic solids with randomly rough surfaces is studied. We present results for such high contact pressures that the area of real contact percolates, giving rise to sealed-off domains with pressurized fluid at the interface. The theoretical predictions are compared to experimental data for a simple model system (a rubber block squeezed against a flat glass plate), and for prefilled syringes, where the rubber plunger stopper is lubricated by a high-viscosity silicon oil to ensure functionality of the delivery device. For the latter system we compare the breakloose (or static) friction, as a function of the time of stationary contact, to the theory prediction.
Kwok, L Stephen; Kuznetsov, Valerian A; Ho, Arthur; Coroneo, Minas T
2003-04-01
Peripheral light-focusing (PLF) is an occult form of ultraviolet radiation (UVR) hazardous to the human eye. In PLF, obliquely incident light is refracted from the peripheral cornea to concentrated sites inside the anterior segment. In the current study, the directionality of this phenomenon for UVR and whether PLF is established in outdoor settings exposed to sunlight were investigated. The protection provided by a UV-blocking contact lens was also evaluated. UVA and UVB sensors were placed on the nasal limbus of an anatomically based model eye. The temporal limbus was exposed to a UV light source placed at various angles behind the frontal plane. PLF was quantified with the sensor output. The ensemble was mounted in the orbit of a mannequin head and exposed to sunlight in three insolation environments within the region of Sydney, Australia. PLF for UVA and UVB was determined with no eyewear or with sunglasses and commercially available soft contact lenses, with and without UV-blocking capability. The intensity of UVA peaked at approximately 120 degrees incidence, the level at which the UVB response was also at its maximum. The intensification of UVA was up to x18.3. The intensity of PLF for UVA and UVB was reduced by an order of magnitude by a UV-blocking contact lens, whereas a clear contact lenses had a much lesser effect. Only the UV-blocking contact lens achieved a significant effect on UVA and UVB irradiance in the urban, beach, and mountain locales (P UV-blocking soft contact lenses. Sunglasses may be unable to shield oblique rays, unless side protection is incorporated. Contact lenses can offer UVR protection against all angles of incidence, including the peak-response angle. They can also protect the eye in settings in which the wearing of sunglasses is not feasible or convenient.
advance. Your help is appreciated. Contact us by email Email doepatentscomments@osti.gov NOTE: Email us by phone Phone Phone (865) 241-5275 Contact us in writing Mail U.S. Department of Energy Office of non-federal websites. Their policies may differ from this site. Javascript Not Enabled Email Link
DEFF Research Database (Denmark)
Andersen, K. E.; Johansen, J. D.; Bruze, M.
2001-01-01
The elicitation response in allergic contact dermatitis is dose dependent, but the time-concentration relationship for elicitation has not previously been described. In this study 27 isoeugenol-sensitive patients participated in serial dilution patch tests with isoeugenol and a double-blinded Rep......The elicitation response in allergic contact dermatitis is dose dependent, but the time-concentration relationship for elicitation has not previously been described. In this study 27 isoeugenol-sensitive patients participated in serial dilution patch tests with isoeugenol and a double......-blinded Repeated Open Application Test (ROAT) using two concentrations of isoeugenol, 0.2 and 0.05%. Seven controls without isoeugenol allergy were also included. The participants applied 3.72 +/- 1.57 (mean +/- SD) mg/cm(2) of coded isoeugenol solutions twice a day to a 3 x 3 cm(2) area on the volar aspect...... of the right and left arm, respectively. For each test site the applications continued until a reaction appeared or for a maximum of 28 days. The minimal criteria for a positive reaction regarded as allergic contact dermatitis was persistent erythema at the ROAT test site. All controls were negative and 16...
Energy Technology Data Exchange (ETDEWEB)
Lan Chun; Srisungsitthisunti, Pornsak; Amama, Placidus B; Fisher, Timothy S; Xu Xianfan; Reifenberger, Ronald G [Birck Nanotechnology Center, Purdue University, West Lafayette, IN 47907 (United States)], E-mail: lan0@physics.purdue.edu
2008-03-26
A technique of measuring contact resistance between an individual nanotube and a deposited metallic film is described. Using laser ablation to sequentially shorten the contact length between a nanotube and the evaporated metallic film, the linear resistivity of the nanotube as well as the specific contact resistivity between the nanotube and metallic film can be determined. This technique can be generally used to measure the specific contact resistance that develops between a metallic film and a variety of different nanowires and nanotubes.
Weighted Maximum-Clique Transversal Sets of Graphs
Chuan-Min Lee
2011-01-01
A maximum-clique transversal set of a graph G is a subset of vertices intersecting all maximum cliques of G. The maximum-clique transversal set problem is to find a maximum-clique transversal set of G of minimum cardinality. Motivated by the placement of transmitters for cellular telephones, Chang, Kloks, and Lee introduced the concept of maximum-clique transversal sets on graphs in 2001. In this paper, we study the weighted version of the maximum-clique transversal set problem for split grap...
Introduction to contact mechanics
Fischer-Cripps, Anthony C
2000-01-01
Contact mechanics deals with the elastic or plastic contact between two solid objects, and is thus intimately connected with such topics as fracture, hardness, and elasticity.This text, intended for advanced undergraduates, begins with an introduction to the mechanical properties of materials, general fracture mechanics, and fractures in brittle solids.This is followed by a detailed discussion of stresses and the nature of elastic and elastic-plastic contact.
Solar cell with back side contacts
Nielson, Gregory N; Okandan, Murat; Cruz-Campa, Jose Luis; Resnick, Paul J; Wanlass, Mark Woodbury; Clews, Peggy J
2013-12-24
A III-V solar cell is described herein that includes all back side contacts. Additionally, the positive and negative electrical contacts contact compoud semiconductor layers of the solar cell other than the absorbing layer of the solar cell. That is, the positive and negative electrical contacts contact passivating layers of the solar cell.
Campbell, Darren; Carnell, Sarah Maria; Eden, Russell John
2013-05-01
Contact angle, as a representative measure of surface wettability, is often employed to interpret contact lens surface properties. The literature is often contradictory and can lead to confusion. This literature review is part of a series regarding the analysis of hydrogel contact lenses using contact angle techniques. Here we present an overview of contact angle terminology, methodology, and analysis. Having discussed this background material, subsequent parts of the series will discuss the analysis of contact lens contact angles and evaluate differences in published laboratory results. The concepts of contact angle, wettability and wetting are presented as an introduction. Contact angle hysteresis is outlined and highlights the advantages in using dynamic analytical techniques over static methods. The surface free energy of a material illustrates how contact angle analysis is capable of providing supplementary surface characterization. Although single values are able to distinguish individual material differences, surface free energy and dynamic methods provide an improved understanding of material behavior. The frequently used sessile drop, captive bubble, and Wilhelmy plate techniques are discussed. Their use as both dynamic and static methods, along with the advantages and disadvantages of each technique, is explained. No single contact angle technique fully characterizes the wettability of a material surface, and the application of complimenting methods allows increased characterization. At present, there is not an ISO standard method designed for soft materials. It is important that each contact angle technique has a standard protocol, as small protocol differences between laboratories often contribute to a variety of published data that are not easily comparable.
International Nuclear Information System (INIS)
Biondi, L.
1998-01-01
The charging for a service is a supplier's remuneration for the expenses incurred in providing it. There are currently two charges for electricity: consumption and maximum demand. While no problem arises about the former, the issue is more complicated for the latter and the analysis in this article tends to show that the annual charge for maximum demand arbitrarily discriminates among consumer groups, to the disadvantage of some [it
Occupational issues of allergic contact dermatitis
DEFF Research Database (Denmark)
Andersen, Klaus E
2003-01-01
Occupational contact dermatitis is often of multifactorial origin, and it is difficult to determine the relative significance of the various contributing factors. Contact allergies are relevant in 20-50% of recognised occupational contact dermatitis cases. The reported frequency in different...... of the reported contact allergies is often uncertain. Many occupational contact dermatitis patients with documented contact allergies develop chronic eczema, in spite of work changes and attempted allergen avoidance. Recognition/non-recognition of a notified case may be based on circumstantial evidence, because......-effect relationships to be established with increased certainty. For prevention of allergic contact dermatitis it was a major step forward, with mandatory ingredient labelling of cosmetic products. However, improved labelling of the presence of contact allergens in household and industrial products is needed...
Directory of Open Access Journals (Sweden)
Trisna Yuliharti Tersinanda
2013-07-01
Full Text Available Normal 0 false false false EN-US X-NONE X-NONE Allergic contact dermatitis is an immunologic reaction that tends to involve the surrounding skin and may even spread beyond affected sites. This skin disease is one of the more frequent, and costly dermatologic problems. Recent data from United Kingdom and United States suggest that the percentage of occupational contact dermatitis due to allergy may be much higher, thus raising the economic impact of occupational allergic contact dermatitis. There is not enough data about the epidemiology of allergic contact dermatitis in Indonesia, however based on research that include beautician in Denpasar, about 27,6 percent had side effect of cosmetics, which is 25,4 percent of it manifested as allergic contact dermatitis. Diagnosis of allergic contact dermatitis is based on anamnesis, physical examination, patch test, and this disease should be distinguished from other eczematous skin disease. The management is prevention of allergen exposure, symptomatic treatment, and physicochemical barrier /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin-top:0in; mso-para-margin-right:0in; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0in; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}
Andersson, P. B. U.; Kropp, W.
2008-11-01
Rolling resistance, traction, wear, excitation of vibrations, and noise generation are all attributes to consider in optimisation of the interaction between automotive tyres and wearing courses of roads. The key to understand and describe the interaction is to include a wide range of length scales in the description of the contact geometry. This means including scales on the order of micrometres that have been neglected in previous tyre/road interaction models. A time domain contact model for the tyre/road interaction that includes interfacial details is presented. The contact geometry is discretised into multiple elements forming pairs of matching points. The dynamic response of the tyre is calculated by convolving the contact forces with pre-calculated Green's functions. The smaller-length scales are included by using constitutive interfacial relations, i.e. by using nonlinear contact springs, for each pair of contact elements. The method is presented for normal (out-of-plane) contact and a method for assessing the stiffness of the nonlinear springs based on detailed geometry and elastic data of the tread is suggested. The governing equations of the nonlinear contact problem are solved with the Newton-Raphson iterative scheme. Relations between force, indentation, and contact stiffness are calculated for a single tread block in contact with a road surface. The calculated results have the same character as results from measurements found in literature. Comparison to traditional contact formulations shows that the effect of the small-scale roughness is large; the contact stiffness is only up to half of the stiffness that would result if contact is made over the whole element directly to the bulk of the tread. It is concluded that the suggested contact formulation is a suitable model to include more details of the contact interface. Further, the presented result for the tread block in contact with the road is a suitable input for a global tyre/road interaction model
Microbial adherence to cosmetic contact lenses.
Chan, Ka Yin; Cho, Pauline; Boost, Maureen
2014-08-01
To investigate whether cosmetic contact lenses (CCL) with surface pigments affect microbial adherence. Fifteen brands of CCL were purchased from optical, non-optical retail outlets, and via the Internet. A standardized rub-off test was performed on each CCL (five lenses per brand) to confirm the location of the pigments. The rub-off test comprised gentle rubbing on the surfaces of each CCL with wetted cotton buds for a maximum of 20 rubs per surface. A new set of CCL (five lenses per brand) were incubated in Pseudomonas aeruginosa overnight. Viable counts of adhered bacteria were determined by the number of colony-forming units (CFU) on agar media on each lens. The adherence of P. aeruginosa as well as Staphylococcus aureus and Serratia marcescens to three brands of CCL (A-C) (five lenses per brand) were also compared to their adherences on their clear counterparts. Only two of the 15 brands of CCL tested (brands B and C) had pigments that did not detach with the rub-off test. The remaining 13 brands of CCL all failed the rub-off test and these lenses showed higher P. aeruginosa adherence (8.7 × 10(5)-1.9 × 10(6) CFU/lens). Brands B and C lenses showed at least six times less bacterial adhesion than the other 13 brands. Compared to their clear counterparts, bacterial adherence to brands B and C lenses did not differ significantly, whereas brand A lenses showed significantly higher adherence. Surface pigments on CCL resulted in significantly higher bacterial adherence. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Halperin, Eran; Crisp, Richard J; Husnu, Shenel; Trzesniewski, Kali H; Dweck, Carol S; Gross, James J
2012-12-01
Intergroup contact plays a crucial role in moderating long-term conflicts. Unfortunately, the motivation to make contact with outgroup members is usually very low in such conflicts. We hypothesized that one limiting factor is the belief that groups cannot change, which leads to increased intergroup anxiety and decreased contact motivation. To test this hypothesis, we experimentally manipulated beliefs about group malleability in the context of the conflict between Greek and Turkish Cypriots and then assessed intergroup anxiety and motivation to engage in intergroup contact. Turkish Cypriots who were led to believe that groups can change (with no mention of the specific groups involved) reported lower levels of intergroup anxiety and higher motivation to interact and communicate with Greek Cypriots in the future, compared with those who were led to believe that groups cannot change. This effect of group malleability manipulation on contact motivation was mediated by intergroup anxiety. PsycINFO Database Record (c) 2012 APA, all rights reserved.
Contact Allergy in Danish Healthcare Workers
DEFF Research Database (Denmark)
Schwensen, Jakob F; Menné, Torkil; Sommerlund, Mette
2016-01-01
Contact dermatitis in healthcare workers is a pan-European problem. We conducted a retrospective observational study of the patch-test results of 1402 healthcare workers and 1402 matched controls with contact dermatitis who were treated at 3 hospitals departments in Denmark between 2007 and 2014....... The primary objective was to determine whether healthcare work was associated with contact allergy to thiuram mix. Unadjusted univariate analyses revealed that healthcare work was significantly associated with occupational contact dermatitis and hand dermatitis. Contact allergy to thiuram mix was more common...... in healthcare workers was significantly associated with having occupational contact dermatitis, hand dermatitis and older age. In conclusion, we report here a potential problem of contact allergy to thiurams in healthcare workers with contact dermatitis. Legislative authorities may in the future focus...
Full Text Available ... the United States. All contact lenses are medical devices that require a prescription and proper fitting by an eye-care professional. Retailers that sell contacts without a ...
De Felício, Cláudia Maria; Mapelli, Andrea; Sidequersky, Fernanda Vincia; Tartaglia, Gianluca M; Sforza, Chiarella
2013-06-01
Mandibular kinematic and standardized surface electromyography (sEMG) characteristics of masticatory muscles of subjects with short lasting TMD of mild-moderate severity were examined. Volunteers were submitted to clinical examination and questionnaire of severity. Ten subjects with TMD (age 27.3years, SD 7.8) and 10 control subjects without TMD, matched by age, were selected. Mandibular movements were recorded during free maximum mouth opening and closing (O-C) and unilateral, left and right, gum chewing. sEMG of the masseter and temporal muscles was performed during maximum teeth clenching either on cotton rolls or in intercuspal position, and during gum chewing. sEMG indices were obtained. Subjects with TMD, relative to control subjects, had lower relative mandibular rotation at the end of mouth opening, larger mean number of intersection between interincisal O-C paths during mastication and smaller asymmetry between working and balancing side, with participation beyond the expected of the contralateral muscles (Pkinematic parameters and the EMG indices of the static test, although some changes in the mastication were observed. Copyright © 2013 Elsevier Ltd. All rights reserved.
Fragrance allergic contact dermatitis.
Cheng, Judy; Zug, Kathryn A
2014-01-01
Fragrances are a common cause of allergic contact dermatitis in Europe and in North America. They can affect individuals at any age and elicit a spectrum of reactions from contact urticaria to systemic contact dermatitis. Growing recognition of the widespread use of fragrances in modern society has fueled attempts to prevent sensitization through improved allergen identification, labeling, and consumer education. This review provides an overview and update on fragrance allergy. Part 1 discusses the epidemiology and evaluation of suspected fragrance allergy. Part 2 reviews screening methods, emerging fragrance allergens, and management of patients with fragrance contact allergy. This review concludes by examining recent legislation on fragrances and suggesting potential additions to screening series to help prevent and detect fragrance allergy.
Space time manifolds and contact structures
Directory of Open Access Journals (Sweden)
K. L. Duggal
1990-01-01
Full Text Available A new class of contact manifolds (carring a global non-vanishing timelike vector field is introduced to establish a relation between spacetime manifolds and contact structures. We show that odd dimensional strongly causal (in particular, globally hyperbolic spacetimes can carry a regular contact structure. As examples, we present a causal spacetime with a non regular contact structure and a physical model [Gödel Universe] of Homogeneous contact manifold. Finally, we construct a model of 4-dimensional spacetime of general relativity as a contact CR-submanifold.
Nature Contacts: Employee Wellness in Healthcare.
Trau, Deborah; Keenan, Kimberly A; Goforth, Meggan; Large, Vernon
2016-04-01
This study was designed to ascertain the amount of outdoor, indoor, and indirect nature contact exposures hospital employees have in a workweek. Hospital employees have been found particularly vulnerable to work-related stress. Increasing the nature contact exposure for hospital employees can reduce perceived stress; stress-related health behaviors; and stress-related health outcomes from outdoor, indoor, and indirect exposures to nature. Staff on the fourth floor postsurgical unit of a large hospital (N = 42) were ask to participate in an employee questionnaire "nature contact questionnaire". This 16-item nature environment questionnaire measures the amount and types of nature contact exposures employees have during a workweek. Majority of employees reported few, if any, nature contact exposures, specifically in the area of outdoor nature contacts with limited indoor and indirect contacts. These results indicated that employees on the fourth floor postsurgical floor have limited ability to reduce stress through nature contact exposures which could impact their perceived levels of work stress and stress-related behaviors and health outcomes. Nature contact exposures are both a relatively easy and an inexpensive way to improve employee stress. These findings indicate limitations to employees' exposure to nature contacts. Healthcare environments would benefit from a concerted effort to provide increased outdoor, indoor, and indirect nature contact exposures for employees. © The Author(s) 2015.
Energy Technology Data Exchange (ETDEWEB)
Bravetti, Alessandro, E-mail: alessandro.bravetti@iimas.unam.mx [Instituto de Investigaciones en Matemáticas Aplicadas y en Sistemas, Universidad Nacional Autónoma de México, A. P. 70543, México, DF 04510 (Mexico); Cruz, Hans, E-mail: hans@ciencias.unam.mx [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, A. P. 70543, México, DF 04510 (Mexico); Tapias, Diego, E-mail: diego.tapias@nucleares.unam.mx [Facultad de Ciencias, Universidad Nacional Autónoma de México, A.P. 70543, México, DF 04510 (Mexico)
2017-01-15
In this work we introduce contact Hamiltonian mechanics, an extension of symplectic Hamiltonian mechanics, and show that it is a natural candidate for a geometric description of non-dissipative and dissipative systems. For this purpose we review in detail the major features of standard symplectic Hamiltonian dynamics and show that all of them can be generalized to the contact case.
Contact materials for nanoelectronics
Alshareef, Husam N.; Quevedo-Ló pez, Manuel Angel Quevedo; Majhi, Prashant
2011-01-01
In this article, we review current research activities in contact material development for electronic and nanoelectronic devices. A fundamental issue in contact materials research is to understand and control interfacial reactions and phenomena
Directory of Open Access Journals (Sweden)
T Nguyen
2017-06-01
Full Text Available This paper studies the contact of general rough curved surfaces having nearly identical geometries, assuming the contact at each differential area obeys the model proposed by Greenwood and Williamson. In order to account for the most general gross geometry, principles of differential geometry of surface are applied. This method while requires more rigorous mathematical manipulations, the fact that it preserves the original surface geometries thus makes the modeling procedure much more intuitive. For subsequent use, differential geometry of axis-symmetric surface is considered instead of general surface (although this “general case” can be done as well in Chapter 3.1. The final formulas for contact area, load, and frictional torque are derived in Chapter 3.2.
Establishing an upper bound on contact resistivity of ohmic contacts to n-GaN nanowires
International Nuclear Information System (INIS)
Blanchard, Paul; Bertness, Kris A; Harvey, Todd; Sanford, Norman
2014-01-01
Contact resistivity ρ c is an important figure of merit in evaluating and improving the performance of electronic and optoelectronic devices. Due to the small size, unique morphology, and uncertain transport properties of semiconductor nanowires (NWs), measuring ρ c of contacts to NWs can be particularly challenging. In this work, Si-doped n-GaN NWs were grown by molecular beam epitaxy. Four-contact structures with 20 nm Ti/200 nm Al contacts were fabricated on individual NWs by photolithography, and the contacts were annealed to achieve ohmic behavior. Two-point resistances R 23 and four-point collinear resistances R 23collinear were measured between the middle two contacts on each NW. These resistances were then modeled by taking into account the non-uniform distribution of current flow along the length of each contact. Contrary to the assumption that the resistance difference R 23 −R 23collinear is equal to the total contact resistance R c , the distributed-current-flow contact model shows that R 23 −R 23collinear ≪ R c when ρ c is sufficiently small. Indeed, the measured R 23 −R 23collinear was so small in these devices that it was within the measurement uncertainty, meaning that it was not possible to directly calculate ρ c from these data. However, it was possible to calculate an upper bound on ρ c for each device based on the largest possible value of R 23 −R 23collinear . In addition, we took into account the large uncertainties in the NW transport properties by numerically maximizing ρ c with respect to the uncertainty range of each measured and assumed parameter in the contact model. The resulting upper limits on ρ c ranged from 4.2 × 10 −6 to 7.6 × 10 −6 Ω cm 2 , indicating that 20 nm Ti/200 nm Al is a good choice of ohmic contact for moderately-doped n-GaN NWs. The measurement and numerical analysis demonstrated here offer a general approach to modeling ohmic contact resistivity via NW four
Occlusal stability in shortened dental arches.
Witter, D J; Creugers, N H; Kreulen, C M; de Haan, A F
2001-02-01
Shortened dental arches consisting of anterior and premolar teeth have been shown to meet oral functional demands. However, the occlusal stability may be at risk as a result of tooth migration. The aim of this nine-year study was to investigate occlusal stability in shortened dental arches as a function over time. Occlusal stability indicators were: 'interdental spacing', 'occlusal contacts of anterior teeth in Intercuspal Position', 'overbite', 'occlusal tooth wear', and 'alveolar bone support'. Subjects with shortened dental arches (n = 74) were compared with subjects with complete dental arches (controls, n = 72). Repeated-measurement regression analyses were applied to assess age-dependent variables in the controls and to relate the occlusal changes to the period of time since the treatment that led to the shortened dental arches. Compared with complete dental arches, shortened dental arches had similar overbite and occlusal tooth wear. They showed more interdental spacing in the premolar regions, more anterior teeth in occlusal contact, and lower alveolar bone scores. Since the differences remained constant over time, we conclude that shortened dental arches can provide long-term occlusal stability. Occlusal changes were self-limiting, indicating a new occlusal equilibrium.
Caero, Jennifer E; Cohen, Philip R
2012-09-15
Fiddler's neck refers to an irritant contact dermatitis on the submandibular neck of violin and viola players and an allergic contact dermatitis to nickel from the bracket attaching the violin to the chin rest on the violinist's supraclavicular neck. A 26-year-old woman developed submandibular and supraclavicular left neck lesions corresponding to the locations of the chin rest and bracket that was attached to her violin that held it against her neck when she played. Substitution of a composite chin rest, which did not contain nickel, and the short-term application of a low potency topical corticosteroid cream, resulted in complete resolution of the allergic contact dermatitis supraclavicular neck lesion. The irritant contact dermatitis submandibular neck lesion persisted. In conclusion, violin players are predisposed to developing irritant contact dermatitis or allergic contact dermatitis from the chin rest. We respectfully suggest that the submandibular neck lesions from contact with the chin rest be referred to as 'fiddler's neck - type 1,' whereas the supraclavicular neck lesions resulting from contact of the bracket holding the chin rest in place be called 'fiddler's neck - type 2.' A composite chin rest should be considered in patients with a preceding history of allergic contact dermatitis to nickel.
Manlove, Kezia R; Cassirer, E Frances; Plowright, Raina K; Cross, Paul C; Hudson, Peter J
2017-07-01
Understanding both contact and probability of transmission given contact are key to managing wildlife disease. However, wildlife disease research tends to focus on contact heterogeneity, in part because the probability of transmission given contact is notoriously difficult to measure. Here, we present a first step towards empirically investigating the probability of transmission given contact in free-ranging wildlife. We used measured contact networks to test whether bighorn sheep demographic states vary systematically in infectiousness or susceptibility to Mycoplasma ovipneumoniae, an agent responsible for bighorn sheep pneumonia. We built covariates using contact network metrics, demographic information and infection status, and used logistic regression to relate those covariates to lamb survival. The covariate set contained degree, a classic network metric describing node centrality, but also included covariates breaking the network metrics into subsets that differentiated between contacts with yearlings, ewes with lambs, and ewes without lambs, and animals with and without active infections. Yearlings, ewes with lambs, and ewes without lambs showed similar group membership patterns, but direct interactions involving touch occurred at a rate two orders of magnitude higher between lambs and reproductive ewes than between any classes of adults or yearlings, and one order of magnitude higher than direct interactions between multiple lambs. Although yearlings and non-reproductive bighorn ewes regularly carried M. ovipneumoniae, our models suggest that a contact with an infected reproductive ewe had approximately five times the odds of producing a lamb mortality event of an identical contact with an infected dry ewe or yearling. Consequently, management actions targeting infected animals might lead to unnecessary removal of young animals that carry pathogens but rarely transmit. This analysis demonstrates a simple logistic regression approach for testing a priori
[Contact allergy to henna tattoos].
Steinkjer, Bjarte; Stangeland, Katarina Zak; Mikkelsen, Carsten Sauer
2011-03-18
Tattoos with henna colours have become very popular and the prevalence of contact allergy seems to increase. This is a short review article based on our own clinical experience and literature identified through a search in PubMed with the words "henna", "paraphenylendiamin" and "allergic contact dermatitis." A case report is included. It is well documented that many experience skin reactions after henna tattoos. The cause is almost always contact allergy to the azo compound paraphenylendiamin, which is added to speed up the process and make the colour darker. Most people, including children, get henna tattoos during vacations in Asia or the Mediterranean. Established contact allergy is permanent. Many hair-colour products contain paraphenylendiamin, and persons with contact allergy against the product may develop a very strong contact allergic eczema by use of such substances. Acute reactions are treated with local cortisone products, or with systemic steroids. Cross reaction to substances with a similar chemical structure may occur. Tattoos with paraphenylendiamin-containing henna colours should be avoided.
Bias dependent specic contact resistance of phase change material to metal contacts
Roy, Deepu; in 't Zandt, Micha; Wolters, Robertus A.M.
2010-01-01
Knowledge of contact resistance of phase change materials (PCM) to metal electrodes is important for scaling, device modeling and optimization of phase change random access memory (PCRAM) cells. In this article, we report the systematic determination of the speci_c contact resistance (_c) with
49 CFR 230.24 - Maximum allowable stress.
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Maximum allowable stress. 230.24 Section 230.24... Allowable Stress § 230.24 Maximum allowable stress. (a) Maximum allowable stress value. The maximum allowable stress value on any component of a steam locomotive boiler shall not exceed 1/4 of the ultimate...
Electrical characterisation of ruthenium Schottky contacts on n-Ge (1 0 0)
Energy Technology Data Exchange (ETDEWEB)
Chawanda, Albert, E-mail: albert.chawanda@up.ac.za [Department of Physics, University of Pretoria, Pretoria 0002 (South Africa); Department of Physics, Midlands State University, Bag 9055, Gweru (Zimbabwe); Nyamhere, Cloud [Department of Physics, Nelson Mandela Metropolitan University, Box 7700, Port Elizabeth 6031 (South Africa); Auret, Francois D.; Nel, Jacqueline M.; Mtangi, Wilbert; Diale, Mmatsae [Department of Physics, University of Pretoria, Pretoria 0002 (South Africa)
2012-05-15
Ruthenium (Ru) Schottky contacts were fabricated on n-Ge (1 0 0) by electron beam deposition. Current-voltage (I-V), deep level transient spectroscopy (DLTS), and Laplace-DLTS techniques were used to characterise the as-deposited and annealed Ru/n-Ge (1 0 0) Schottky contacts. The variation of the electrical properties of the Ru samples annealed between 25 Degree-Sign C and 575 Degree-Sign C indicates the formation of two phases of ruthenium germanide. After Ru Schottky contacts fabrication, an electron trap at 0.38 eV below the conduction band with capture cross section of 1.0 Multiplication-Sign 10{sup -14} cm{sup -2} is the only detectable electron trap. The hole traps at 0.09, 0.15, 0.27 and 0.30 eV above the valence band with capture cross sections of 7.8 Multiplication-Sign 10{sup -13} cm{sup -2}, 7.1 Multiplication-Sign 10{sup -13} cm{sup -2}, 2.4 Multiplication-Sign 10{sup -13} cm{sup -2} and 6.2 Multiplication-Sign 10{sup -13} cm{sup -2}, respectively, were observed in the as-deposited Ru Schottky contacts. The hole trap H(0.30) is the prominent single acceptor level of the E-centre, and H(0.09) is the third charge state of the E-centre. H(0.27) shows some reverse annealing and reaches a maximum concentration at 225 Degree-Sign C and anneals out after 350 Degree-Sign C. This trap is strongly believed to be V-Sb{sub 2} complex formed from the annealing of V-Sb defect centre.
Manda, Hortance; Shah, Pankhil; Polsomboon, Suppaluck; Chareonviriyaphap, Theeraphap; Castro-Llanos, Fanny; Morrison, Amy; Burrus, Roxanne G; Grieco, John P; Achee, Nicole L
2013-01-01
Previous studies have demonstrated contact irritant and spatial repellent behaviors in Aedes aegypti following exposure to sublethal concentrations of chemicals. These sublethal actions are currently being evaluated in the development of a push-pull strategy for Ae. aegypti control. This study reports on mosquito escape responses after exposure to candidate chemicals for a contact irritant focused push-pull strategy using varying concentrations and focal application. Contact irritancy (escape) behavior, knockdown and 24 hour mortality rates were quantified in populations of female Ae. aegypti under laboratory conditions and validated in the field (Thailand and Peru) using experimental huts. Evaluations were conducted using varying concentrations and treatment surface area coverage (SAC) of three pyrethroid insecticides: alphacypermethrin, lambacyhalothrin and deltamethrin. Under laboratory conditions, exposure of Ae. aegypti to alphacypermethrin using the standard field application rate (FAR) resulted in escape responses at 25% and 50% SAC that were comparable with escape responses at 100% SAC. Significant escape responses were also observed at time of exit (by four hours) and 40% increase in escape using ½FAR of alphacypermethrin at 75% SAC compared to a matched chemical-free control. In Peru, however, the maximum increase in Ae. aegypti escape from alphacypermethrin-treated huts was 11%. Results presented here suggest a potential role for sublethal and focal application of contact irritant chemicals in an Ae. aegypti push-pull strategy to reduce human-vector contact inside treated homes. However, the impact of an increase in escape response on dengue virus transmission is currently unknown and will depend on rate of biting on human hosts prior to house exiting.
Jamari, Jamari; Schipper, Dirk J.
2007-01-01
This paper presents theoretical and experimental results of the residual or plastic deformation and the plastic contact area of an elastic–plastic contact of ellipsoid bodies after unloading. There are three regime responses of the deformation and contact area: elastic, elastic–plastic and fully
Contact allergy epidemics and their controls
DEFF Research Database (Denmark)
Thyssen, Jacob Pontoppidan; Johansen, Jeanne Duus; Menné, Torkil
2007-01-01
Contact dermatitis can be severe and lead to sick leave as well as significant healthcare expenses. The aim of this review is to present the published knowledge on 6 historical epidemics of contact allergy to apply this knowledge on the prevention and control of future contact allergy epidemics. ...... to prevent contact allergy epidemics. It is essential that dermatologist, scientists, administrators, and consumers organize and structure known methods to accelerate the control of emerging contact allergens....
Straylight Measurements in Contact Lens Wear
van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.
2010-01-01
Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens
Rosenberger, Matthew R.; Chen, Sihan; Prater, Craig B.; King, William P.
2017-01-01
This paper reports the design, fabrication, and characterization of micromechanical devices that can present an engineered contact stiffness to an atomic force microscope (AFM) cantilever tip. These devices allow the contact stiffness between the AFM tip and a substrate to be easily and accurately measured, and can be used to calibrate the cantilever for subsequent mechanical property measurements. The contact stiffness devices are rigid copper disks of diameters 2-18 μm integrated onto a soft silicone substrate. Analytical modeling and finite element simulations predict the elastic response of the devices. Measurements of tip-sample interactions during quasi-static force measurements compare well with modeling simulation, confirming the expected elastic response of the devices, which are shown to have contact stiffness 32-156 N m-1. To demonstrate one application, we use the disk sample to calibrate three resonant modes of a U-shaped AFM cantilever actuated via Lorentz force, at approximately 220, 450, and 1200 kHz. We then use the calibrated cantilever to determine the contact stiffness and elastic modulus of three polymer samples at these modes. The overall approach allows cantilever calibration without prior knowledge of the cantilever geometry or its resonance modes, and could be broadly applied to both static and dynamic measurements that require AFM calibration against a known contact stiffness.
Gosálbez, J; Wright, W M D; Jiang, W; Carrión, A; Genovés, V; Bosch, I
2018-08-01
In this paper, the study of frequency-dependent ultrasonic attenuation in strongly heterogeneous cementitious materials is addressed. To accurately determine the attenuation over a wide frequency range, it is necessary to have suitable excitation techniques. We have analysed two kinds of ultrasound techniques: contact ultrasound and airborne non-contact ultrasound. The mathematical formulation for frequency-dependent attenuation has been established and it has been revealed that each technique may achieve similar results but requires specific different calibration processes. In particular, the airborne non-contact technique suffers high attenuation due to energy losses at the air-material interfaces. Thus, its bandwidth is limited to low frequencies but it does not require physical contact between transducer and specimen. In contrast, the classical contact technique can manage higher frequencies but the measurement depends on the pressure between the transducer and the specimen. Cement specimens have been tested with both techniques and frequency attenuation dependence has been estimated. Similar results were achieved at overlapping bandwidth and it has been demonstrated that the airborne non-contact ultrasound technique could be a viable alternative to the classical contact technique. Copyright © 2018 Elsevier B.V. All rights reserved.
Contact lens surface by electron beam
International Nuclear Information System (INIS)
Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin
2011-01-01
Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility
... Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados ... truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non- ...
Contact radiotherapy. Report of technological assessment
International Nuclear Information System (INIS)
Ortholan, Cecile; Melin, Nicole; Lee-Robin, Sun Hae; David, Denis Jean; Pages, Frederique; Devaud, Christine; Noel, Georges; Biga, Julie; Moty-Monnereau, Celine; Canet, Philippe; Lascols, Sylvie; Lamas, Muriel; Ramdine, Jessica; Tuil, Louise
2008-10-01
This report aims at assessing safety, indications, the role in therapeutic strategy, and efficiency of contact radiotherapy. It also aims at answering questions like: is the contact radiotherapy technique validated? What are the indications for contact radiotherapy? What about the efficiency and safety of contact radiotherapy? After a presentation of preliminary notions on radiotherapy (radiation types, dose, and irradiation techniques), the report presents this specific technique of contact radiotherapy: definition, devices, use recommendations, issues of radiation protection, modalities of performance of a contact radiotherapy session, and concerned pathologies. Then, based on a literature survey, this report addresses the various concerned tumours (skin, rectum, brain, breast), indicates some general information about these tumours (epidemiological data, anatomy and classification, therapeutic options, radiotherapy), and proposes an assessment of the efficiency and safety of contact radiotherapy
A Feasibility Study on the Worn Area Estimation by Measuring a Contact Resistance (I)
International Nuclear Information System (INIS)
Lee, Young-Ho; Kim, Hyung-Kyu
2007-01-01
In order to improve the fretting wear resistance of the nuclear fuel rod with considering the effect of the contacting spring shape, it is necessary to examine the formation procedure of the worn area during the fretting wear experiments with including its shape, size and the debris removal path. This is because the wear volume and the maximum wear depth are dominantly affected by the worn area and the wear resistance of the nuclear fuel rod was dominantly affected by the spring shape rather than the test environment and the contact mode (i.e. impact, sliding, rubbing, etc.). Unfortunately, it is almost impossible to archive the size and shape of the worn area on real-time basis because the contact surfaces are always hidden. If we could measure the worn area properties during fretting wear tests, it enables us to promptly estimate the wear resistance or behavior with various contacting spring shapes. Generally, fretting wear degradation is generated by the localized plastic deformation, fracture and finally detachment of wear debris. Generally, wear debris easily oxidized by frictional heat, test environment, etc. From the previous studies, most of the wear debris was detached from the worn surface in the distilled water condition while the wear debris in the dry condition remained on or adhered to the worn surface. At this time, it is reasonable that the accumulated wear debris on the worn surface is existed in the form of oxide. If small amount of electric current was applied between the contacting surfaces, wear debris could be an obstacle to flow the electric current. This means that the variation of the contact resistance under constant electric current during the fretting wear tests has much information on the formation of the worn area even though the applying current could accelerate the oxidation of the generated wear debris. So, in this study, fretting wear tests have been performed with applying an electric current in room temperature air in order to
Contact and non-contact ultrasonic measurement in the food industry: a review
International Nuclear Information System (INIS)
Mohd Khairi, Mohd Taufiq; Ibrahim, Sallehuddin; Md Yunus, Mohd Amri; Faramarzi, Mahdi
2016-01-01
The monitoring of the food manufacturing process is vital since it determines the safety and quality level of foods which directly affect the consumers’ health. Companies which produce high quality products will gain trust from consumers. This factor helps the companies to make profits. The use of efficient and appropriate sensors for the monitoring process can also reduce cost. The food assessing process based on an ultrasonic sensor has attracted the attention of the food industry due to its excellent capabilities in several applications. The utilization of low or high frequencies for the ultrasonic transducer has provided an enormous benefit for analysing, modifying and guaranteeing the quality of food. The contact and non-contact ultrasonic modes for measurement also contributed significantly to the food processing. This paper presents a review of the application of the contact and non-contact mode of ultrasonic measurement focusing on safety and quality control areas. The results from previous researches are shown and elaborated. (topical review)
Contact and non-contact ultrasonic measurement in the food industry: a review
Taufiq Mohd Khairi, Mohd; Ibrahim, Sallehuddin; Yunus, Mohd Amri Md; Faramarzi, Mahdi
2016-01-01
The monitoring of the food manufacturing process is vital since it determines the safety and quality level of foods which directly affect the consumers’ health. Companies which produce high quality products will gain trust from consumers. This factor helps the companies to make profits. The use of efficient and appropriate sensors for the monitoring process can also reduce cost. The food assessing process based on an ultrasonic sensor has attracted the attention of the food industry due to its excellent capabilities in several applications. The utilization of low or high frequencies for the ultrasonic transducer has provided an enormous benefit for analysing, modifying and guaranteeing the quality of food. The contact and non-contact ultrasonic modes for measurement also contributed significantly to the food processing. This paper presents a review of the application of the contact and non-contact mode of ultrasonic measurement focusing on safety and quality control areas. The results from previous researches are shown and elaborated.
A maximum power point tracking for photovoltaic-SPE system using a maximum current controller
Energy Technology Data Exchange (ETDEWEB)
Muhida, Riza [Osaka Univ., Dept. of Physical Science, Toyonaka, Osaka (Japan); Osaka Univ., Dept. of Electrical Engineering, Suita, Osaka (Japan); Park, Minwon; Dakkak, Mohammed; Matsuura, Kenji [Osaka Univ., Dept. of Electrical Engineering, Suita, Osaka (Japan); Tsuyoshi, Akira; Michira, Masakazu [Kobe City College of Technology, Nishi-ku, Kobe (Japan)
2003-02-01
Processes to produce hydrogen from solar photovoltaic (PV)-powered water electrolysis using solid polymer electrolysis (SPE) are reported. An alternative control of maximum power point tracking (MPPT) in the PV-SPE system based on the maximum current searching methods has been designed and implemented. Based on the characteristics of voltage-current and theoretical analysis of SPE, it can be shown that the tracking of the maximum current output of DC-DC converter in SPE side will track the MPPT of photovoltaic panel simultaneously. This method uses a proportional integrator controller to control the duty factor of DC-DC converter with pulse-width modulator (PWM). The MPPT performance and hydrogen production performance of this method have been evaluated and discussed based on the results of the experiment. (Author)
Full Text Available ... Cleveland. "This is far from the truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ...
Full Text Available ... Costume Contacts May Contain Chemicals Harmful to Eyes Four Ways Over-the-Counter Costume Contact Lenses Can ... was in severe pain and on medication for four weeks, and couldn't see well enough to ...
Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...
Full Text Available ... glow-in-the-dark lizard lenses, costume contacts can certainly add a spooky, eye-popping touch. But ... consideration as a standard contact lens because they can be purchased over-the-counter or on the ...
Full Text Available ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to ... wear costume contact lenses for Halloween or any time of year, follow these guidelines: Get an eye ...
Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...
Full Text Available ... Cleveland. "This is far from the truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager ... the lenses. Never share contact lenses with another person. Get follow up exams with your eye care ...
Nezafati, Kaveh A; Carroll, Bryan; Storrs, Frances J; Cruz, Ponciano D
2013-01-01
The American Contact Dermatitis Society (ACDS) is the principal organization representing the subspecialty of contact dermatitis in the United States. The aim of this study was to characterize ACDS members with respect to demographic characteristics, patch-test practices, and sentiments regarding the Society and its journal Dermatitis. We conducted cross-sectional postal and online surveys of ACDS members. More than a third of ACDS members responded to the survey, 92% of whom practice dermatology, and most of whom are community practitioners. Responders manage patients with allergic and irritant dermatitis at a similar frequency. On average, they patch test 4 patients per week using 66 allergens per patient, which often include customized trays. Almost half of these practitioners learned patch testing from their residency programs. Most of the responders read and value the Society journal, value the Contact Allergen Management Program database, and attend society meetings. The ACDS is comprised overwhelmingly of dermatologists who are primarily community-based, young relative to the start of their practices, and use the Society's resources for continuing education.
A planar PDMS micropump using in-contact minimized-leakage check valves
International Nuclear Information System (INIS)
Ni, Junhui; Li, Beizhi; Huang, Fengliang; Wang, Bin; Lin, Qiao
2010-01-01
We present a micropump with a simple planar design featuring compliant in-contact check valves in a single layer, which allows for a simple structure and easy system integration. The micropump, based on poly(dimethylsiloxane) (PDMS), primarily consists of a pneumatically driven thin membrane, a pump chamber, and two in-plane check valves. The pair of check valves is based on an in-contact flap–stopper configuration and is able to minimize leakage flow, greatly enhancing the reliability and performance of the micropump. Systematic experimental characterization of the micropump has been performed in terms of the frequency response of the pumping flow rate with respect to factors including device geometry (e.g. chamber height) and operating parameters (e.g. pneumatic driving pressure and backpressure). The results demonstrate that this micropump is capable of reliably generating a maximum flow rate of 41 µL min −1 and operating against a high backpressure of up to 25 kPa. In addition, a lumped-parameter theoretical model for the planar micropump is also developed for accurate analysis of the device behavior. These results demonstrate the capability of this micropump for diverse applications in lab-on-a-chip systems.
Lee, SeungGeun; Forman, Charles A.; Lee, Changmin; Kearns, Jared; Young, Erin C.; Leonard, John T.; Cohen, Daniel A.; Speck, James S.; Nakamura, Shuji; DenBaars, Steven P.
2018-06-01
We report the first demonstration of III–nitride vertical-cavity surface-emitting lasers (VCSELs) with tunnel junction (TJ) intracavity contacts grown completely by metal–organic chemical vapor deposition (MOCVD). For the TJs, n++-GaN was grown on in-situ activated p++-GaN after buffered HF surface treatment. The electrical properties and epitaxial morphologies of the TJs were first investigated on TJ LED test samples. A VCSEL with a TJ intracavity contact showed a lasing wavelength of 408 nm, a threshold current of ∼15 mA (10 kA/cm2), a threshold voltage of 7.8 V, a maximum output power of 319 µW, and a differential efficiency of 0.28%.
Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...
Full Text Available ... contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering ... Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at ...
Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...
Full Text Available ... Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados ... truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non- ...
Nigerian Food Journal: Contact
African Journals Online (AJOL)
Nigerian Food Journal. ... Nigerian Food Journal: Contact. Journal Home > About the Journal > Nigerian Food Journal: Contact. Log in or Register to get access to full text downloads. ... Mailing Address. Department of Food Science and Technology University of Agriculture, Makurdi, Nigeria ...
Lake Basin Fetch and Maximum Length/Width
Minnesota Department of Natural Resources — Linear features representing the Fetch, Maximum Length and Maximum Width of a lake basin. Fetch, maximum length and average width are calcuated from the lake polygon...
Maximum permissible voltage of YBCO coated conductors
Energy Technology Data Exchange (ETDEWEB)
Wen, J.; Lin, B.; Sheng, J.; Xu, J.; Jin, Z. [Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai (China); Hong, Z., E-mail: zhiyong.hong@sjtu.edu.cn [Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai (China); Wang, D.; Zhou, H.; Shen, X.; Shen, C. [Qingpu Power Supply Company, State Grid Shanghai Municipal Electric Power Company, Shanghai (China)
2014-06-15
Highlights: • We examine three kinds of tapes’ maximum permissible voltage. • We examine the relationship between quenching duration and maximum permissible voltage. • Continuous I{sub c} degradations under repetitive quenching where tapes reaching maximum permissible voltage. • The relationship between maximum permissible voltage and resistance, temperature. - Abstract: Superconducting fault current limiter (SFCL) could reduce short circuit currents in electrical power system. One of the most important thing in developing SFCL is to find out the maximum permissible voltage of each limiting element. The maximum permissible voltage is defined as the maximum voltage per unit length at which the YBCO coated conductors (CC) do not suffer from critical current (I{sub c}) degradation or burnout. In this research, the time of quenching process is changed and voltage is raised until the I{sub c} degradation or burnout happens. YBCO coated conductors test in the experiment are from American superconductor (AMSC) and Shanghai Jiao Tong University (SJTU). Along with the quenching duration increasing, the maximum permissible voltage of CC decreases. When quenching duration is 100 ms, the maximum permissible of SJTU CC, 12 mm AMSC CC and 4 mm AMSC CC are 0.72 V/cm, 0.52 V/cm and 1.2 V/cm respectively. Based on the results of samples, the whole length of CCs used in the design of a SFCL can be determined.
Measuring The Contact Resistances Of Photovoltaic Cells
Burger, D. R.
1985-01-01
Simple method devised to measure contact resistances of photovoltaic solar cells. Method uses readily available equipment and applicable at any time during life of cell. Enables evaluation of cell contact resistance, contact-end resistance, contact resistivity, sheet resistivity, and sheet resistivity under contact.
Directory of Open Access Journals (Sweden)
Luanfang Duan
2018-03-01
Full Text Available In the present work, the contact heat transfer between the granular materials and heating plates inside plate rotary heat exchanger (PRHE was investigated. The heat transfer coefficient is dominated by the contact heat transfer coefficient at hot wall surface of the heating plates and the heat penetration inside the solid bed. A plot scale PRHE with a diameter of Do = 273 mm and a length of L = 1000 mm has been established. Quartz sand with dp = 2 mm was employed as the experimental material. The operational parameters were in the range of ω = 1 – 8 rpm, and F = 15, 20, 25, 30%, and the effect of these parameters on the time-average contact heat transfer coefficient was analyzed. The time-average contact heat transfer coefficient increases with the increase of rotary speed, but decreases with the increase of the filling degree. The measured data of time-average heat transfer coefficients were compared with theoretical calculations from Schlünder’s model, a good agreement between the measurements and the model could be achieved, especially at a lower rotary speed and filling degree level. The maximum deviation between the calculated data and the experimental data is approximate 10%. Keywords: Rotary heat exchanger, Contact heat transfer, Granular material, Heating plate, Overloaded
Large deformation contact mechanics of a pressurized long rectangular membrane. II. Adhesive contact
Srivastava, Abhishek; Hui, Chung-Yuen
2013-01-01
In part I of this work, we presented a theory for adhesionless contact of a pressurized neo-Hookean plane-strain membrane to a rigid substrate. Here, we extend our theory to include adhesion using a fracture mechanics approach. This theory is used to study contact hysteresis commonly observed in experiments. Detailed analysis is carried out to highlight the differences between frictionless and no-slip contact. Membrane detachment is found to be strongly dependent on adhesion: for low adhesion, the membrane ‘pinches-off’, whereas for large adhesions, it detaches unstably at finite contact (‘pull-off’). Expressions are derived for the critical adhesion needed for pinch-off to pull-off transition. Above a threshold adhesion, the membrane exhibits bistability, two stable states at zero applied pressure. The condition for bistability for both frictionless and no-slip boundary conditions is obtained explicitly. PMID:24353472
Receiver function estimated by maximum entropy deconvolution
Institute of Scientific and Technical Information of China (English)
吴庆举; 田小波; 张乃铃; 李卫平; 曾融生
2003-01-01
Maximum entropy deconvolution is presented to estimate receiver function, with the maximum entropy as the rule to determine auto-correlation and cross-correlation functions. The Toeplitz equation and Levinson algorithm are used to calculate the iterative formula of error-predicting filter, and receiver function is then estimated. During extrapolation, reflective coefficient is always less than 1, which keeps maximum entropy deconvolution stable. The maximum entropy of the data outside window increases the resolution of receiver function. Both synthetic and real seismograms show that maximum entropy deconvolution is an effective method to measure receiver function in time-domain.
Occupational contact dermatitis in hairdressers
DEFF Research Database (Denmark)
Schwensen, Jakob F; Johansen, Jeanne Duus; Veien, Niels K
2013-01-01
BACKGROUND: Occupational contact dermatitis among hairdressers is frequent, owing to daily exposure to irritants and allergens. OBJECTIVES: To identify sensitization to the most common allergens associated with the occupation of hairdressing. METHODS: Patch test results of 399 hairdressers and 1995...... matched controls with contact dermatitis, registered by the Danish Contact Dermatitis Group between January 2002 and December 2011, were analysed. All patients were patch tested with the European baseline series, and hairdressers were additionally tested with the hairdressing series. RESULTS: Occupational...... contact dermatitis (p dermatitis was less commonly observed among hairdressers (21.3%) than among controls (29.4%) (p
Computational dosimetry for grounded and ungrounded human models due to contact current
International Nuclear Information System (INIS)
Chan, Kwok Hung; Hattori, Junya; Laakso, Ilkka; Hirata, Akimasa; Taki, Masao
2013-01-01
This study presents the computational dosimetry of contact currents for grounded and ungrounded human models. The uncertainty of the quasi-static (QS) approximation of the in situ electric field induced in a grounded/ungrounded human body due to the contact current is first estimated. Different scenarios of cylindrical and anatomical human body models are considered, and the results are compared with the full-wave analysis. In the QS analysis, the induced field in the grounded cylindrical model is calculated by the QS finite-difference time-domain (QS-FDTD) method, and compared with the analytical solution. Because no analytical solution is available for the grounded/ungrounded anatomical human body model, the results of the QS-FDTD method are then compared with those of the conventional FDTD method. The upper frequency limit for the QS approximation in the contact current dosimetry is found to be 3 MHz, with a relative local error of less than 10%. The error increases above this frequency, which can be attributed to the neglect of the displacement current. The QS or conventional FDTD method is used for the dosimetry of induced electric field and/or specific absorption rate (SAR) for a contact current injected into the index finger of a human body model in the frequency range from 10 Hz to 100 MHz. The in situ electric fields or SAR are compared with the basic restrictions in the international guidelines/standards. The maximum electric field or the 99th percentile value of the electric fields appear not only in the fat and muscle tissues of the finger, but also around the wrist, forearm, and the upper arm. Some discrepancies are observed between the basic restrictions for the electric field and SAR and the reference levels for the contact current, especially in the extremities. These discrepancies are shown by an equation that relates the current density, tissue conductivity, and induced electric field in the finger with a cross-sectional area of 1 cm 2 . (paper)
Wang, Guangye; Huang, Wenjun; Song, Qi; Liang, Jinfeng
2017-11-01
This study aims to analyze the contact areas and pressure distributions between the femoral head and mortar during normal walking using a three-dimensional finite element model (3D-FEM). Computed tomography (CT) scanning technology and a computer image processing system were used to establish the 3D-FEM. The acetabular mortar model was used to simulate the pressures during 32 consecutive normal walking phases and the contact areas at different phases were calculated. The distribution of the pressure peak values during the 32 consecutive normal walking phases was bimodal, which reached the peak (4.2 Mpa) at the initial phase where the contact area was significantly higher than that at the stepping phase. The sites that always kept contact were concentrated on the acetabular top and leaned inwards, while the anterior and posterior acetabular horns had no pressure concentration. The pressure distributions of acetabular cartilage at different phases were significantly different, the zone of increased pressure at the support phase distributed at the acetabular top area, while that at the stepping phase distributed in the inside of acetabular cartilage. The zones of increased contact pressure and the distributions of acetabular contact areas had important significance towards clinical researches, and could indicate the inductive factors of acetabular osteoarthritis. Copyright © 2016. Published by Elsevier Taiwan.
Experimental investigation of direct contact three phase boiling heat transfer
International Nuclear Information System (INIS)
Bruce, W.D.
1981-01-01
The system which was studied in the present work consisted of one liquid undergoing vaporization by contact with a hotter immiscible liquid. The liquids and vapor were contacted in a counterflow spray column with only differential increases in vapor quality. Experiments yielded vertical temperature profiles, flow rates of the phases, liquid holdups, pressure drops, and a characterization of flow patterns. A micro-computer was utilized for measuring temperatures in the column at the rate of 1500 to 1600 times per second at several depths. Analysis of the experimental data indicate that the maximum temperature difference between the phases is 0.5F 0 , and that a temperature crossover occurs at the lower end of the column. The heat transfer fluid undergoes flash vaporization at its inlet at the top of the column, and much of its sensible heat is tranferred to the dispersed phase near the top of the column. Temperature profiles along the length of the boiler are nearly flat, and very little heat transfer occurs in the lower part of the boiler. A chemical method was developed for measuring effective interfacial area in a direct contact boiler. The theoretical basis of the method is discussed, and physico-chemical data necessary for application of the technique are reported. Water solubility of methyl salicylate was measured as a function of temperature, and the second order reaction rate coefficient for saponification of methyl salicylate by sodium hydroxide was determined from sodium hydroxide concentration versus time data and a computer model of a well-mixed semibatch reactor. The activation energy for the reaction was found to be 9.58 kilocalories per gram mole
Influence of the contacting scheme in simulations of radial silicon nanorod solar cells
International Nuclear Information System (INIS)
Voigt, Felix; Stelzner, Thomas; Christiansen, Silke H.
2012-01-01
Silicon nanorod solar cells were simulated using the Silvaco Technical Computer Aided Design (TCAD) software suite. For reasons of speed optimization the simulations were performed in cylinder coordinates taking advantage of the model's symmetry. Symmetric doping was assumed with a dopant density of 10 18 cm −3 in the p-type core and in the n-type shell, and the location of the pn-junction was chosen such that the space charge region was located adjacent to the shell surface. Two contact configurations were explored. In configuration A the cathode contact was wrapped around the semiconductor nanorod, while in configuration B the cathode was assumed just on top of the nanorod. In both cases the anode was located at the bottom of the rod. Cell efficiency was optimized with regard to rod radius and rod length. Optimization was performed in a three-step procedure consisting in radius optimization, length optimization and again radius optimization. A maximum in efficiency with respect to rod length L was visible in configuration A, leading to an optimum value of L = 48 μm. This maximum is explained by the combination of an increase of short-circuit current density J sc and a decrease of open-circuit voltage U oc with L. In configuration B, J sc also increases with L, but U oc stays rather constant and the maximum in efficiency only appears at very large values of L ≈ 12 mm. We restricted the rod length to L ≤ 100 μm for further optimization, in order to stay in an experimentally feasible range. During the optimization of rod radius R in configuration A the open circuit voltage increased continuously, while short circuit current density stayed rather constant. This leads to an increase in efficiency with R, which only stops at very large radii, where R starts to be comparable with L. In configuration B efficiency is almost independent of R, provided that the radius is large enough to comprise a well-formed space charge region, here only a shallow maximum can be
Influence of the contacting scheme in simulations of radial silicon nanorod solar cells
Energy Technology Data Exchange (ETDEWEB)
Voigt, Felix, E-mail: felix.voigt@uni-oldenburg.de [Institute of Photonic Technology, Jena (Germany); Institute of Physics, University of Oldenburg (Germany); Stelzner, Thomas [Institute of Photonic Technology, Jena (Germany); Christiansen, Silke H. [Institute of Photonic Technology, Jena (Germany); Max Planck Institute for the Science of Light, Erlangen (Germany)
2012-10-01
Silicon nanorod solar cells were simulated using the Silvaco Technical Computer Aided Design (TCAD) software suite. For reasons of speed optimization the simulations were performed in cylinder coordinates taking advantage of the model's symmetry. Symmetric doping was assumed with a dopant density of 10{sup 18} cm{sup -3} in the p-type core and in the n-type shell, and the location of the pn-junction was chosen such that the space charge region was located adjacent to the shell surface. Two contact configurations were explored. In configuration A the cathode contact was wrapped around the semiconductor nanorod, while in configuration B the cathode was assumed just on top of the nanorod. In both cases the anode was located at the bottom of the rod. Cell efficiency was optimized with regard to rod radius and rod length. Optimization was performed in a three-step procedure consisting in radius optimization, length optimization and again radius optimization. A maximum in efficiency with respect to rod length L was visible in configuration A, leading to an optimum value of L = 48 {mu}m. This maximum is explained by the combination of an increase of short-circuit current density J{sub sc} and a decrease of open-circuit voltage U{sub oc} with L. In configuration B, J{sub sc} also increases with L, but U{sub oc} stays rather constant and the maximum in efficiency only appears at very large values of L Almost-Equal-To 12 mm. We restricted the rod length to L {<=} 100 {mu}m for further optimization, in order to stay in an experimentally feasible range. During the optimization of rod radius R in configuration A the open circuit voltage increased continuously, while short circuit current density stayed rather constant. This leads to an increase in efficiency with R, which only stops at very large radii, where R starts to be comparable with L. In configuration B efficiency is almost independent of R, provided that the radius is large enough to comprise a well-formed space
Contact Quality in Participation
DEFF Research Database (Denmark)
Simonsen, Jesper; Jensen, Olav Storm
2016-01-01
We investigate the concept of participation from the perspective of quality of the contact in the communicative interactions between participants. We argue for the need for an academic-personal competence that qualifies the human contact central in all Participatory Design (PD) activities as a way...
McCarty, C A; Thomason, J J; Gordon, K; Hurtig, M; Bignell, W
2015-11-01
To add to the existing data on impact loading of the metacarpophalangeal (MCP) joint as a precursor to assessing the potential role of impact in joint disease. To examine the effect of impact loading on contact areas of the first phalanx (P1) and proximal sesamoids (PS) with the third metacarpal (McIII) under 3 hoof-strike conditions (toe-first, flat, heel-first). Randomised, repeated controlled experiment using cadaver material. Eight cadaver limbs were subjected to randomised, repeated controlled trials where the hoof was struck by a pendulum impact machine (impact velocity 3.55 m/s) under 3 strike conditions. Data from pressure sensitive film placed over medial and lateral McIII condyles and lateromedially across the dorsal aspect of McIII were quantified: total areas of P1 and PS contact (cm(2) ) at maximum recorded pressure; centroid locations of contact areas relative to the sagittal ridge (cm) and transverse ridge (cm) and dispersion of pixels (cm(4) ) for each McIII condyle (medial/lateral). The effect of the strike conditions on each variable were statistically tested using repeated-measures ANOVA (α = 0.05). Contact area between P1 and McIII condyles fell in well-defined areas bounded by the sagittal and transverse ridge, contact areas from PS were smaller and widely dispersed across McIII palmar border. Ratio of contact area of P1 to PS was 2.83 (Pcontact area (P>0.54) CONCLUSIONS: Contact at impact (primarily from P1 and distally situated on McIII), contrasts with contact areas at midstance from both P1 and PS, symmetrically placed. Under impact, the greatest contact area was on the dorsal aspect of the medial condyle and coincides with the area subjected to the greatest increase in subchondral bone stiffening in joint disease. © 2014 EVJ Ltd.
Nanoscale roughness contact in a slider-disk interface.
Hua, Wei; Liu, Bo; Yu, Shengkai; Zhou, Weidong
2009-07-15
The nanoscale roughness contact between molecularly smooth surfaces of a slider-disk interface in a hard disk drive is analyzed, and the lubricant behavior at very high shear rate is presented. A new contact model is developed to study the nanoscale roughness contact behavior by classifying various forms of contact into slider-lubricant contact, slider-disk elastic contact and plastic contact. The contact pressure and the contact probabilities of the three types of contact are investigated. The new contact model is employed to explain and provide insight to an interesting experimental result found in a thermal protrusion slider. The protrusion budget for head surfing in the lubricant, which is the ideal state for contact recording, is also discussed.
Nanoscale roughness contact in a slider-disk interface
International Nuclear Information System (INIS)
Hua Wei; Liu Bo; Yu Shengkai; Zhou Weidong
2009-01-01
The nanoscale roughness contact between molecularly smooth surfaces of a slider-disk interface in a hard disk drive is analyzed, and the lubricant behavior at very high shear rate is presented. A new contact model is developed to study the nanoscale roughness contact behavior by classifying various forms of contact into slider-lubricant contact, slider-disk elastic contact and plastic contact. The contact pressure and the contact probabilities of the three types of contact are investigated. The new contact model is employed to explain and provide insight to an interesting experimental result found in a thermal protrusion slider. The protrusion budget for head surfing in the lubricant, which is the ideal state for contact recording, is also discussed.
Directory of Open Access Journals (Sweden)
Renu M Magdum
2013-01-01
Full Text Available Aim: To study the corneal endothelial changes after soft contact lens wear, to correlate these changes with the duration of soft contact lens wear, and to study the pattern of use and preferences of contact lens among young adults. Materials and Methods: This observational study was carried out in 100 eyes of 50 soft contact lens users aged between 19 and 27 years. Both eyes of 50 medical students who had never worn contact lenses served as controls. Data from each subject were collected using a structured questionnaire of 24 items that included demographic profile, pattern of contact lens use, symptoms, brand name, number of years worn, and hours of daily wear. These data were analyzed using Chi square for association. Specular microscopy was done using TOPCON SP-3000P. Computerized morphometry was used to evaluate central corneal thickness, size, shape, mean cellular density, hexagonality, coefficient of variation, and polymegathism of the corneal cells . Results: It was found that central corneal thickness was 0.532 ± 0.0309 mm in lens users and 0.514 ± 0.03 mm in controls, cell density was 2570.91 ± 432.06 cells/mm 2 in lens users and 2723.17 ± 327.64 cells/mm 2 in controls, while hexagonality was 54.81 ± 39.72% in lens users and 67.65 ± 36.49% in controls. Conclusion: Despite the known effects of long duration of soft contact lens use on corneal endothelial cell morphology, this study could not draw a significant correlation between them. However, a significant difference was found in the corneal endothelial thickness, cell density, and hexagonality. Among the soft contact lens users, 62% used soft disposable type while 38% used soft extended wear contact lens. Contact lenses were preferred over spectacles for better cosmetic appearance, comfort, and wider visual field.
Baker, Kate C; Crockett, Carolyn M; Lee, Grace H; Oettinger, Brooke C; Schoof, Valérie; Thom, Jinhee P
2012-01-01
Pair housing for caged macaques in the laboratory generally allows unrestricted tactile contact but, less commonly, may involve limited contact via grooming-contact bars or perforated panels. The purpose of using this protected contact housing, which prevents entry into pair-mates' cages, typically is to accommodate research and management requirements. The study used behavioral data collected on 12 pairs of female longtailed macaques (Macaca fascicularis) at the Washington National Primate Research Center and 7 pairs of female rhesus macaques (Macaca mulatta) housed at the Tulane National Primate Research Center to assess the relative benefits of protected versus full protected contact. The study collected data in stable pairs housed first in protected contact followed by full contact. Species combined, the study found the presence of the panel was associated with lower levels of social grooming and higher levels of self-grooming, abnormal behavior, and tension-related behavior. Within species, only the protected- versus full-contact contrasts for abnormal and tension were statistically significant-and only for rhesus macaques. Results suggest that for female rhesus macaques, potential disadvantages or inconveniences of full contact should be balanced against the improved behavioral profile in comparison to protected contact. The use of protected contact among female longtailed macaques does not appear to require the same cost-benefit analysis. Copyright © Taylor & Francis Group, LLC
Zhang, Bo
2018-04-14
The thermal stability and contact resistance of TaAlN thin films as electrical contacts to SiGe thermoelectric elements are reported. We demonstrate that a sharp interface is maintained after the device annealed at 800°C for over 100h, indicating that no interdiffusion takes place between TaAlN and SiGe. A specific contact resistivity of (2.1±1.3)×10−6Ω-cm2 for p-type SiGe and (2.8±1.6)×10−5 Ω-cm2 for n-type SiGe is demonstrated after the high temperature annealing. These results show that TaAlN is a promising contact material for high temperature thermoelectrics such as SiGe.
Body contact and body language
DEFF Research Database (Denmark)
Winther, Helle
2008-01-01
and the boundaries between self and world. In western societies, the modern premises for contact are in some ways developing from close contact to virtual communication. With this breadth of perspective in mind, the question is whether conscious and experimental work with body contact and body language in move......ment psychology and education provide potential for intense personal development as well as for social and cultural learning processes. This performative research project originates from the research project entitled, Movement Psychology: The Language of the Body and the Psychology of Movement based......Body contact and body language are unique and existential and, although culturally dependent and socially embodied, they are also universal communication forms. For small children all over the world, warm, close and nourishing body contact is fundamental to their embodied experience of themselves...
Full Text Available ... Get follow up exams with your eye care provider. If you notice redness, swelling, excessive discharge, pain or discomfort from wearing contact lenses, remove the lenses and seek immediate medical attention from an ophthalmologist. Related resources: Learn how to properly care for contact lenses . ...
DEFF Research Database (Denmark)
Andersen, Klaus Ejner; Benezra, C; Burrows, D
1987-01-01
In recent years, there has been a dramatic rise in our understanding of contact dermatitis. This paper is a review of our knowledge of the mechanisms involved in contact dermatitis and related phenomena, the investigation of these events and the emergence of significant new allergens during...
Full Text Available ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to enhance their costumes. From ... MD, professor of ophthalmology at Case Western Reserve University in Cleveland. "This is far ... Use Facts About Colored Contacts and Halloween Safety Colored ...
Directory of Open Access Journals (Sweden)
Yunfeng Shan
2008-01-01
Full Text Available Genomes and genes diversify during evolution; however, it is unclear to what extent genes still retain the relationship among species. Model species for molecular phylogenetic studies include yeasts and viruses whose genomes were sequenced as well as plants that have the fossil-supported true phylogenetic trees available. In this study, we generated single gene trees of seven yeast species as well as single gene trees of nine baculovirus species using all the orthologous genes among the species compared. Homologous genes among seven known plants were used for validation of the finding. Four algorithms—maximum parsimony (MP, minimum evolution (ME, maximum likelihood (ML, and neighbor-joining (NJ—were used. Trees were reconstructed before and after weighting the DNA and protein sequence lengths among genes. Rarely a gene can always generate the “true tree” by all the four algorithms. However, the most frequent gene tree, termed “maximum gene-support tree” (MGS tree, or WMGS tree for the weighted one, in yeasts, baculoviruses, or plants was consistently found to be the “true tree” among the species. The results provide insights into the overall degree of divergence of orthologous genes of the genomes analyzed and suggest the following: 1 The true tree relationship among the species studied is still maintained by the largest group of orthologous genes; 2 There are usually more orthologous genes with higher similarities between genetically closer species than between genetically more distant ones; and 3 The maximum gene-support tree reflects the phylogenetic relationship among species in comparison.
Emotional Satisfaction of Customer Contacts
Güngör, Hüseyin
2007-01-01
For marketing and customer services researchers and professionals who are interested in customer contacts, customer satisfaction and loyalty issues. Contact centers are playing a pivotal role in customer services of the 21st century. Nevertheless, despite their growing importance and presence, contact centers are increasingly becoming the center for customer frustration, and frequently associated with negative comments in the media. Therefore, this research explores the Emotional, Cognitive, ...
Geometry-Dependent Electrostatics near Contact Lines
International Nuclear Information System (INIS)
Chou, Tom
2001-01-01
Long-ranged electrostatic interactions in electrolytes modify contact angles on charged substrates in a scale and geometry-dependent manner. For angles measured at scales smaller than the typical Debye screening length, the wetting geometry near the contact line must be explicitly considered. Using variational and asymptotic methods, we derive new transcendental equations for the contact angle as functions of the electrostatic potential only at the three phase contact line. Analytic expressions are found in certain limits and compared with predictions for contact angles measured with lower resolution. An estimate for electrostatic contributions to line tension is also given
Chang, Joonho; Freivalds, Andris; Sharkey, Neil A; Kong, Yong-Ku; Mike Kim, H; Sung, Kiseok; Kim, Dae-Min; Jung, Kihyo
2017-11-01
A cadaver study was conducted to investigate the effects of triggering conditions (trigger grip span, contact location, and internal tendon force) on index finger triggering force and the force efficiency of involved tendons. Eight right human cadaveric hands were employed, and a motion simulator was built to secure and control the specimens. Index finger triggering forces were investigated as a function of different internal tendon forces (flexor digitorum profundus + flexor digitorum superficialis = 40, 70, and 100 N), trigger grip spans (40, 50, and 60 mm), and contact locations between the index finger and a trigger. Triggering forces significantly increased when internal tendon forces increased from 40 to 100 N. Also, trigger grip spans and contact locations had significant effects on triggering forces; maximum triggering forces were found at a 50 mm span and the most proximal contact location. The results revealed that only 10-30% of internal tendon forces were converted to their external triggering forces. Copyright © 2017 Elsevier Ltd. All rights reserved.
Association between Contact allergy and Psoriasis
DEFF Research Database (Denmark)
Bangsgaard, Nannie
2011-01-01
6. SUMMERY 6.1 Summery in English Allergic contact dermatitis (ACD) and psoriasis are the two most prevalent skin diseases in the western world. ACD is the clinical manifestation of contact allergy. Contact allergy and psoriasis are both due to inflammatory mechanisms involving the innate...... and adaptive immune system. Psoriasis is conceived to be an autoimmune disease. Recent studies have suggested an inverse relation between contact allergy and autoimmune diseases. The association between contact allergy and psoriasis could reveal mechanistic insights into both inflammatory processes....... The overall aim of this PhD study was to investigate the association between contact allergy and autoimmune disease, with focus on psoriasis. The work was done in three study parts. Part I Epidemiological studies. Part II Sensitization study and Part III Experimental studies. In part I the association between...
New aspects in allergic contact dermatitis
DEFF Research Database (Denmark)
Mørtz, Charlotte G; Andersen, Klaus Ejner
2008-01-01
PURPOSE OF REVIEW: To give selected new information on contact allergy and allergic contact dermatitis with focus on diagnostic procedures and pitfalls. RECENT FINDINGS: Recent studies dealing with common contact allergens have improved our understanding of the relationship between positive patch...... contact dermatitis. The main culprits include fragrance chemicals, preservatives, and hair dyes. We are all more or less exposed to cosmetics and topical drugs on a daily basis. The labelling requirements given in the Cosmetics Directive is of great help in tracing the causative allergenic ingredients...... tests and the clinical interpretation and consequences for the patient. SUMMARY: Nickel allergy is still the most common contact allergy in Europe in spite of full implementation of the EU Nickel Directive in 2001. Contact allergens in cosmetics and topical drugs are another common cause of allergic...
Rovira-Lastra, B; Flores-Orozco, E I; Ayuso-Montero, R; Peraire, M; Martinez-Gomis, J
2016-04-01
The aim of this cross-sectional study was to determine the preferred chewing side and whether chewing side preference is related to peripheral, functional or postural lateral preferences. One hundred and forty-six adults with natural dentition performed three masticatory assays, each consisting of five trials of chewing three pieces of silicon placed into a latex bag for 20 cycles, either freestyle or unilaterally on the right- or left-hand side. Occlusal contact area in the intercuspal position, maximum bite force, masticatory performance and cycle duration were measured and the lateral asymmetry of these variables was calculated. Laterality tests were performed to determine handedness, footedness, earedness and eyedness as functional preferences, and hand-clasping, arm-folding and leg-crossing as postural lateral preferences. The preferred chewing side was determined using three different methods: assessment of the first chewing cycle for each trial, calculation of the asymmetry index from all cycles and application of a visual analogue scale. Bivariate relationship and multiple linear regression analyses were performed. Among unilateral chewers, 77% of them preferred the right side for chewing. The factors most closely related to the preferred chewing side were asymmetry of bite force, asymmetry of masticatory performance and earedness, which explained up to 16% of the variance. Although several functional or postural lateral preferences seem to be related to the preferred chewing side, peripheral factors such as asymmetry of bite force and of masticatory performance are the most closely related to the preferred chewing side in adults with natural dentition. © 2015 John Wiley & Sons Ltd.
Souza, Juliana A; Pasinato, Fernanda; Corrêa, Eliane C R; da Silva, Ana Maria T
2014-01-01
The aim of this study was to evaluate body posture and the distribution of plantar pressure at physiologic rest of the mandible and during maximal intercuspal positions in subjects with and without temporomandibular disorder (TMD). Fifty-one subjects were assessed by the Diagnostic Criteria for Research on Temporomandibular Disorders and divided into a symptomatic group (21) and an asymptomatic group (30). Postural analysis for both groups was conducted using photogrammetry (SAPo version 0.68; University of São Paulo, São Paulo, Brazil). The distribution of plantar pressures was evaluated by means of baropodometry (Footwork software), at physiologic rest and maximal intercuspal positions. Of 18 angular measurements, 3 (17%) were statistically different between the groups in photogrammetric evaluation. The symptomatic group showed more pronounced cervical distance (P = .0002), valgus of the right calcaneus (P = .0122), and lower pelvic tilt (P = .0124). The baropodometry results showed the TMD subjects presented significantly higher rearfoot and lower forefoot distribution than those in the asymptomatic group. No differences were verified in maximal intercuspal position in the between-group analysis and between the 2 mandibular positions in the within-group analysis. Subjects with and without TMD presented with global body posture misalignment. Postural changes were more pronounced in the subjects with TMD. In addition, symptomatic subjects presented with abnormal plantar pressure distribution, suggesting that TMD may have an influence on the postural system. Copyright © 2014 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
Full Text Available ... eye-care team . Consumer warning about the improper use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering buying approved by the FDA? Check the FDA's database of approved contact lenses . Related Stories Prevent Infection ...
Timeliness of contact tracing among flight passengers for influenza A/H1N1 2009
Directory of Open Access Journals (Sweden)
Swaan Corien M
2011-12-01
laboratory confirmation in relation to maximum time to provide postexposure prophylaxis when deciding to install contact tracing measures. International standardization of CT guidelines is recommended.
Maximum neutron flux in thermal reactors
International Nuclear Information System (INIS)
Strugar, P.V.
1968-12-01
Direct approach to the problem is to calculate spatial distribution of fuel concentration if the reactor core directly using the condition of maximum neutron flux and comply with thermal limitations. This paper proved that the problem can be solved by applying the variational calculus, i.e. by using the maximum principle of Pontryagin. Mathematical model of reactor core is based on the two-group neutron diffusion theory with some simplifications which make it appropriate from maximum principle point of view. Here applied theory of maximum principle are suitable for application. The solution of optimum distribution of fuel concentration in the reactor core is obtained in explicit analytical form. The reactor critical dimensions are roots of a system of nonlinear equations and verification of optimum conditions can be done only for specific examples
DEFF Research Database (Denmark)
Schwensen, Jakob F; Menné, Torkil; Andersen, Klaus E
2014-01-01
, MCI/MI and BIT between 2009 and 2013 were included. RESULTS: MI contact allergy showed a significantly increased trend in prevalence from 1.8% in 2009 to 4.2% in 2012 (p dermatitis mainly drove the increase in 2012. Adjusted logistic regression analysis showed that MI...... sensitization was significantly associated with occupational exposures, hand and facial dermatitis, age > 40 years, and the occupational groups of tile setters/terrazzo workers, machine operators, and painters. MCI/MI contact allergy was significantly associated with the following high-risk occupations......BACKGROUND: In recent years, the prevalence of contact allergy to isothiazolinones has reached epidemic levels. Few studies have presented data on occupations at risk of developing contact allergy to isothiazolinones. OBJECTIVES: To present demographics and examine risk factors for sensitization...
A real-time non-contact monitoring method of subsea pipelines
Directory of Open Access Journals (Sweden)
Song Dalei
2015-01-01
Full Text Available To monitoring the subsea pipeline in real-time, a special potentiometric sensor array and a potential prediction model are presented in this paper. Firstly, to measure the potential of seawater, a special potentiometric sensor array with Ag/AgCl all-solid-state reference electrodes is first developed in this paper. Secondly, according to the obtained distribution law of electric field intensities a prediction model of the pipeline potentials is developed. Finally, the potentiometric sensor array is applied in sink experiment and the prediction model is validated by the sink measurements. The maximum error for pipeline potential prediction model is 1.1 mV. The proposed non-contact monitoring method for subsea pipeline can predict the potential of sea pipeline in real-time, thus providing important information for further subsea pipeline maintenance.
Directory of Open Access Journals (Sweden)
Courtenay B Bombara
Full Text Available Information on contacts between individuals within a population is crucial to inform disease control strategies, via parameterisation of disease spread models. In this study we investigated the use of dog-borne video cameras-in conjunction with global positioning systems (GPS loggers-to both characterise dog-to-dog contacts and to estimate contact rates. We customized miniaturised video cameras, enclosed within 3D-printed plastic cases, and attached these to nylon dog collars. Using two 3400 mAh NCR lithium Li-ion batteries, cameras could record a maximum of 22 hr of continuous video footage. Together with a GPS logger, collars were attached to six free roaming domestic dogs (FRDDs in two remote Indigenous communities in northern Australia. We recorded a total of 97 hr of video footage, ranging from 4.5 to 22 hr (mean 19.1 per dog, and observed a wide range of social behaviours. The majority (69% of all observed interactions between community dogs involved direct physical contact. Direct contact behaviours included sniffing, licking, mouthing and play fighting. No contacts appeared to be aggressive, however multiple teeth baring incidents were observed during play fights. We identified a total of 153 contacts-equating to 8 to 147 contacts per dog per 24 hr-from the videos of the five dogs with camera data that could be analysed. These contacts were attributed to 42 unique dogs (range 1 to 19 per video which could be identified (based on colour patterns and markings. Most dog activity was observed in urban (houses and roads environments, but contacts were more common in bushland and beach environments. A variety of foraging behaviours were observed, included scavenging through rubbish and rolling on dead animal carcasses. Identified food consumed included chicken, raw bones, animal carcasses, rubbish, grass and cheese. For characterising contacts between FRDD, several benefits of analysing videos compared to GPS fixes alone were identified in
Directory of Open Access Journals (Sweden)
Г. С. Курчин
2017-03-01
Full Text Available In Russia development of mineral resources is carried out on a truly grand scale, and mining industry is in its essence a basic sector, supporting and facilitating the development of national economy. It predetermines the need of safe and responsible attitude towards riches of our subsoil – mineral resources. With this in mind, one of the key requirements to extraction technologies is minimization of mining losses and ore dilution.The biggest ore losses in the mining block take place in the process of development of contact areas between the ore body and surrounding rocks, due to differences between development pattern and surface of geological contact. Complexity of the contact between ore and surrounding rocks is traditionally characterized by so called «stochastic contact zone». Technological difficulty of extracting ore from the ore – wallrock contact is determined by volatility of geometric parameters in «stochastic contact zone» in the plane of geological contact.Current paper focuses on the issues of standard-setting for mining losses and ore dilution in the process of near-contact zone development. A method is suggested to estimate standard values of losses and ore dilution in stochastic zones. Authors have developed an algorithm of defining the shape of the contact. In the stochastic zone the contact can have a rectangular, sinusoidal, serrate and straight-line shapes. Research has established a relation between the contact shape and amounts of mining losses and ore dilution, formulas to calculate standard values are presented. Using suggested method, standard values for contact ore losses can be obtained in a quicker and more reliable way.
2010-07-27
...-17530; Notice No. 2] RIN 2130-ZA03 Inflation Adjustment of the Ordinary Maximum and Aggravated Maximum... remains at $250. These adjustments are required by the Federal Civil Penalties Inflation Adjustment Act [email protected] . SUPPLEMENTARY INFORMATION: The Federal Civil Penalties Inflation Adjustment Act of 1990...
Amino acid empirical contact energy definitions for fold recognition in the space of contact maps
Directory of Open Access Journals (Sweden)
Fogolari Federico
2003-02-01
Full Text Available Abstract Background Contradicting evidence has been presented in the literature concerning the effectiveness of empirical contact energies for fold recognition. Empirical contact energies are calculated on the basis of information available from selected protein structures, with respect to a defined reference state, according to the quasi-chemical approximation. Protein-solvent interactions are estimated from residue solvent accessibility. Results In the approach presented here, contact energies are derived from the potential of mean force theory, several definitions of contact are examined and their performance in fold recognition is evaluated on sets of decoy structures. The best definition of contact is tested, on a more realistic scenario, on all predictions including sidechains accepted in the CASP4 experiment. In 30 out of 35 cases the native structure is correctly recognized and best predictions are usually found among the 10 lowest energy predictions. Conclusion The definition of contact based on van der Waals radii of alpha carbon and side chain heavy atoms is seen to perform better than other definitions involving only alpha carbons, only beta carbons, all heavy atoms or only backbone atoms. An important prerequisite for the applicability of the approach is that the protein structure under study should not exhibit anomalous solvent accessibility, compared to soluble proteins whose structure is deposited in the Protein Data Bank. The combined evaluation of a solvent accessibility parameter and contact energy allows for an effective gross screening of predictive models.
Half-width at half-maximum, full-width at half-maximum analysis
Indian Academy of Sciences (India)
addition to the well-defined parameter full-width at half-maximum (FWHM). The distribution of ... optical side-lobes in the diffraction pattern resulting in steep central maxima [6], reduc- tion of effects of ... and broad central peak. The idea of.
Liu, Haihu; Ju, Yaping; Wang, Ningning; Xi, Guang; Zhang, Yonghao
2015-09-01
behavior of daughter droplets is significantly different in both branch channels. Also, it is found that the contact angle hysteresis is strengthened with decreasing the viscosity ratio, leading to an earlier droplet breakup and a decrease in the maximum length that the droplet can reach before the breakup. These simulation results manifest that the present multiphase LBM can be a useful substitute to Ba et al. [Phys. Rev. E 88, 043306 (2013)PLEEE81539-375510.1103/PhysRevE.88.043306] for modeling the contact angle hysteresis, and it can be easily implemented with higher computational efficiency.
Full Text Available ... eye-care professional. Retailers that sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. "Many of the lenses found online or in beauty salons, novelty shops or in pop-up ... contact lenses from a retailer that does not ask for a prescription. ...
Heinemann, Martina; Groot, R.A. de
1997-01-01
Ab initio molecular dynamics is used to study the contribution of a single Al atom to an aluminum breakpoint contact during the final stages of breaking and the initial stages of the formation of such a contact. A hysteresis effect is found in excellent agreement with experiment and the form of the
Ageing without detailed balance in the bosonic contact and pair-contact processes: exact results
International Nuclear Information System (INIS)
Baumann, Florian; Henkel, Malte; Pleimling, Michel; Richert, Jean
2005-01-01
Ageing in systems without detailed balance is studied in the exactly solvable bosonic contact process and the critical bosonic pair-contact process. The two-time correlation function and the two-time response function are explicitly found. In the ageing regime, the dynamical scaling of these is analysed and exact results for the ageing exponents and the scaling functions are derived. For the critical bosonic pair-contact process, the autocorrelation and autoresponse exponents agree but the ageing exponents a and b are shown to be distinct
Two-dimensional maximum entropy image restoration
International Nuclear Information System (INIS)
Brolley, J.E.; Lazarus, R.B.; Suydam, B.R.; Trussell, H.J.
1977-07-01
An optical check problem was constructed to test P LOG P maximum entropy restoration of an extremely distorted image. Useful recovery of the original image was obtained. Comparison with maximum a posteriori restoration is made. 7 figures
Contact angle and surface tension measurements of a five-ring polyphenyl ether
Jones, W. R., Jr.
1986-01-01
Contact angle measurements were performed for a five-ring polyphenyl ether isomeric mixture on M-50 steel in a dry nitrogen atmosphere. Two different techniques were used: (1) a tilting plate apparatus, and (2) a sessile drop apparatus. Measurements were made for the temperature range 25 to 190 C. Surface tension was measured by a differential maximum bubble pressure technique over the range 23 to 220 C in room air. The critical surface energy of spreading (gamma /sub c/) was determined for the polyphenyl ether by plotting the cosine of the contact angle (theta) versus the surface tension (gamma /sub LV/). The straight line intercept at cosine theta = 1 is defined as gamma (sub c). Gamma (sub c) was found to be 30.1 dyn/cm for the tilting plate technique and 31.3 dyn/cm for the sessile drop technique. These results indicate that the polyphenyl ether is inherently autophobic (i.e., it will not spread on its own surface film until its surface tension is less than gamma /sub c/). This phenomenon is discussed in light of the wettability and wear problems encountered with this fluid.
International Nuclear Information System (INIS)
Enslin, J.H.R.
1990-01-01
A well engineered renewable remote energy system, utilizing the principal of Maximum Power Point Tracking can be m ore cost effective, has a higher reliability and can improve the quality of life in remote areas. This paper reports that a high-efficient power electronic converter, for converting the output voltage of a solar panel, or wind generator, to the required DC battery bus voltage has been realized. The converter is controlled to track the maximum power point of the input source under varying input and output parameters. Maximum power point tracking for relative small systems is achieved by maximization of the output current in a battery charging regulator, using an optimized hill-climbing, inexpensive microprocessor based algorithm. Through practical field measurements it is shown that a minimum input source saving of 15% on 3-5 kWh/day systems can easily be achieved. A total cost saving of at least 10-15% on the capital cost of these systems are achievable for relative small rating Remote Area Power Supply systems. The advantages at larger temperature variations and larger power rated systems are much higher. Other advantages include optimal sizing and system monitor and control
7 CFR 3565.210 - Maximum interest rate.
2010-01-01
... 7 Agriculture 15 2010-01-01 2010-01-01 false Maximum interest rate. 3565.210 Section 3565.210... AGRICULTURE GUARANTEED RURAL RENTAL HOUSING PROGRAM Loan Requirements § 3565.210 Maximum interest rate. The interest rate for a guaranteed loan must not exceed the maximum allowable rate specified by the Agency in...
Solar Cels With Reduced Contact Areas
Daud, T.; Crotty, G. T.; Kachare, A. H.; Lewis, J. T.
1987-01-01
Efficiency of silicon solar cells increased about 20 percent using smaller metal-contact area on silicon at front and back of each cell. Reduction in contact area reduces surface recombination velocity under contact and thus reduces reverse saturation current and increases opencircuit voltage..
Characteristics of molybdenum bilayer back contacts for Cu(In,Ga)Se2 solar cells on Ti foils
International Nuclear Information System (INIS)
Roger, Charles; Noël, Sébastien; Sicardy, Olivier; Faucherand, Pascal; Grenet, Louis; Karst, Nicolas; Fournier, Hélène; Roux, Frédéric; Ducroquet, Frédérique; Brioude, Arnaud; Perraud, Simon
2013-01-01
Molybdenum back contact properties are critical for Cu(In,Ga)Se 2 (CIGS) solar cell performance on metallic substrates. In this work, we investigated the properties of sputter-deposited Mo bilayer back contacts on Ti foils. The morphology, electrical resistivity, optical reflectance and residual mechanical stress of the bottom Mo layer were modified by varying the working pressure during its deposition. Working pressures ranging from 0.27 Pa to 4.00 Pa were used. The top Mo layer was deposited using constant conditions at a pressure of 0.13 Pa. It was demonstrated that unlike a Mo monolayer, the use of a Mo bilayer allows controlling the mechanical stress at the Mo/CIGS interface without degrading the optical reflectance and the electrical resistance of the back contact. It was also found that the morphology of the bottom Mo layer affects the growth of the top Mo layer, resulting in a modified back contact surface morphology. This induces changes in the crystalline orientation of the CIGS layer. The resulting solar cell characteristics strongly vary as a function of the bottom Mo layer deposition pressure. A bottom Mo layer growth at 2.93 Pa allows improving the solar cell conversion efficiency by 1.5 times compared to a bottom Mo layer deposited at 0.27 Pa. Using the improved Mo bilayer back contact, a maximum solar cell efficiency of 10.0% was obtained without sodium addition nor anti-reflection coating. - Highlights: • Mo bilayer back contacts for Cu(In,Ga)Se 2 solar cells were grown on Ti substrates. • The sputtering pressure of the bottom Mo layer was varied between 0.27 Pa and 4 Pa. • The top Mo layer controls the optical and electrical properties of the back contact. • The structure of the bottom Mo layer influences the morphology of the top Mo layer. • The back contact affects the CIGS texture, device series resistance and efficiency
DEFF Research Database (Denmark)
Mose, Anja P; Lundov, Michael Dyrgaard; Zachariae, Claus
2012-01-01
Background. Painters are among the occupational groups that most commonly experience occupational contact dermatitis, but few investigations exist concerning this occupation. Objectives. To characterize painters with contact dermatitis and identify the most common allergens associated...... with the occupation. Materials and methods. All patch test results of 219 painters and 1095 matched controls registered by the Danish Contact Dermatitis Group between 2001 and 2010 were analysed. Results. Hand eczema (p contact dermatitis (p
Contact activation: a revision.
Schmaier, A H
1997-07-01
In conclusion, a revised view of the contact system has been presented. This system has little to do with the initiation of hemostasis. Like lupus anticoagulants, deficiencies of contact proteins give prolonged APTTs but may be risk factors for thrombosis. BK from kininogens is a potent modulator of vascular biology inducing vasodilation, tissue plasminogen activator release, and prostacyclin liberation. Kininogens, themselves, are selective inhibitors of alpha-thrombin-induced platelet activation preventing alpha-thrombin from cleaving the cloned thrombin receptor after arginine41. Kininogens' alpha-thrombin inhibitory activity exists in intact kininogens, BK, and all of BK's breakdown products. HK also is the pivotal protein for contact protein assembly on endothelium. It is the receptor for prekallikrein which when bound to HK becomes activated to kallikrein by an endothelial cell enzyme system independent of activated forms of plasma factor XII. Prekallikrein activation on endothelial cells results in kinetically favorable single chain urokinase and plasminogen activation. Thus the "physiologic, negatively charged surface" for contact system activation is really the assembly of these proteins on cell membranes and activation by membrane-associated enzymes.
Dynamics of the Molten Contact Line
Sonin, Ain A.; Duthaler, Gregg; Liu, Michael; Torresola, Javier; Qiu, Taiqing
1999-01-01
The purpose of this program is to develop a basic understanding of how a molten material front spreads over a solid that is below its melting point, arrests, and freezes. Our hope is that the work will contribute toward a scientific knowledge base for certain new applications involving molten droplet deposition, including the "printing" of arbitrary three-dimensional objects by precise deposition of individual molten microdrops that solidify after impact. Little information is available at this time on the capillarity-driven motion and arrest of molten contact line regions. Schiaffino and Sonin investigated the arrest of the contact line of a molten microcrystalline wax spreading over a subcooled solid "target" of the same material. They found that contact line arrest takes place at an apparent liquid contact angle that depends primarily on the Stefan number S=c(T(sub f) -T(sub t)/L based on the temperature difference between the fusion point and the target temperature, and proposed that contact line arrest occurs when the liquid's dynamic contact angle approaches the angle of attack of the solidification front just behind the contact line. They also showed, however, that the conventional continuum equations and boundary conditions have no meaningful solution for this angle. The solidification front angle is determined by the heat flux just behind the contact line, and the heat flux is singular at that point. By comparing experiments with numerical computations, Schiaffino and Sonin estimated that the conventional solidification model must break down within a distance of order 0.1 - 1 microns of the contact line. The physical mechanism for this breakdown is as yet undetermined, and no first-principles theory exists for the contact angle at arrest. Schiaffino and Sonin also presented a framework for understanding how to moderate Weber number molten droplet deposition in terms of similarity laws and experimentation. The study is based on experiments with three molten
Allergic contact dermatitis from octylisothiazolinone
DEFF Research Database (Denmark)
Mose, Anja Pahlow; Frost, Simon; Ohlund, Ulf
2013-01-01
Octylisothiazolinone is a biocide that has been reported as a moderate, but rare contact allergen.......Octylisothiazolinone is a biocide that has been reported as a moderate, but rare contact allergen....
Exchange of tears under a contact lens is driven by distortions of the contact lens.
Maki, Kara L; Ross, David S
2014-12-01
We studied the flow of the post-lens tear film under a soft contact lens to understand how the design parameters of contact lenses can affect ocular health. When a soft contact lens is inserted, the blinking eyelid causes the lens to stretch in order to conform to the shape of the eye. The deformed contact lens acts to assume its un-deformed shape and thus generates a suction pressure in the post-lens tear film. In consequence, the post-lens tear fluid moves; it responds to the suction pressure. The suction pressure may draw in fresh fluid from the edge of the lens, or it may eject fluid there, as the lens reassumes its un-deformed shape. In this article, we develop a mathematical model of the flow of the post-lens tear fluid in response to the mechanical suction pressure of a deformed contact lens. We predict the amount of exchange of fluid exchange under a contact lens and we explore the influence of the eye's shape on the rate of exchange of fluid. © The Author 2014. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.
Characterization of CdTe and (CdZn)Te detectors with different metal contacts
Pekárek, J.; Belas, E.; Grill, R.; Uxa, Å.; James, R. B.
2013-09-01
In the present work we studied an influence of different types of surface etching and surface passivation of high resistivity CdZnTe-based semiconductor detector material. The aim was to find the optimal conditions to improve the properties of metal-semiconductor contact. The main effort was to reduce the leakage current and thus get better X-ray and gamma-ray spectrum, i.e. to create a detector operating at room temperature based on this semiconductor material with sufficient energy resolution and the maximum charge collection efficiency. Individual surface treatments were characterized by I-V characteristics, spectral analysis and by determination of the profile of the internal electric field.
On contact modelling in isogeometric analysis
Cardoso, R. P. R.; Adetoro, O. B.
2017-11-01
IsoGeometric Analysis (IGA) has proved to be a reliable numerical tool for the simulation of structural behaviour and fluid mechanics. The main reasons for this popularity are essentially due to: (i) the possibility of using higher order polynomials for the basis functions; (ii) the high convergence rates possible to achieve; (iii) the possibility to operate directly on CAD geometry without the need to resort to a mesh of elements. The major drawback of IGA is the non-interpolatory characteristic of the basis functions, which adds a difficulty in handling essential boundary conditions and makes it particularly challenging for contact analysis. In this work, the IGA is expanded to include frictionless contact procedures for sheet metal forming analyses. Non-Uniform Rational B-Splines (NURBS) are going to be used for the modelling of rigid tools as well as for the modelling of the deformable blank sheet. The contact methods developed are based on a two-step contact search scheme, where during the first step a global search algorithm is used for the allocation of contact knots into potential contact faces and a second (local) contact search scheme where point inversion techniques are used for the calculation of the contact penetration gap. For completeness, elastoplastic procedures are also included for a proper description of the entire IGA of sheet metal forming processes.
Wound-Related Allergic/Irritant Contact Dermatitis.
Alavi, Afsaneh; Sibbald, R Gary; Ladizinski, Barry; Saraiya, Ami; Lee, Kachiu C; Skotnicki-Grant, Sandy; Maibach, Howard
2016-06-01
To provide information from a literature review about the prevention, recognition, and treatment for contact dermatitis. This continuing education activity is intended for physicians and nurses with an interest in skin and wound care. After participating in this educational activity, the participant should be better able to:1. Identify signs and symptoms of and diagnostic measures for contact dermatitis.2. Identify causes and risks for contact dermatitis.3. Select appropriate treatment for contact dermatitis and its prevention. Contact dermatitis to wound care products is a common, often neglected problem. A review was conducted to identify articles relevant to contact dermatitis.A PubMed English-language literature review was conducted for appropriate articles published between January 2000 and December 2015.Contact dermatitis is both irritant (80% of cases) or allergic (20% of cases). Frequent use of potential contact allergens and impaired barrier function of the skin can lead to rising sensitization in patients with chronic wounds. Common known allergens to avoid in wound care patients include fragrances, colophony, lanolin, and topical antibiotics.Clinicians should be cognizant of the allergens in wound care products and the potential for sensitization. All medical devices, including wound dressings, adhesives, and bandages, should be labeled with their complete ingredients, and manufacturers should be encouraged to remove common allergens from wound care products, including topical creams, ointments, and dressings.
Contact Lens Related Corneal Ulcer
Loh, KY; Agarwal, P
2010-01-01
A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...
RISK FACTORS FOR CONTACT LENS COMPLICATIONS
Directory of Open Access Journals (Sweden)
Mirna Štabuc Šilih
2016-04-01
Full Text Available Contact lenses are freely available without professional examination and fitting, as well as without adequate introduction and instructions on handling, disinfection and storage. Contact lenses may have physiological, metabolic and anatomic effect on the eyes, which is manifested both on the eyelids, lacrimal film, conjunctiva and in all layers of the cornea - the epithelium, stroma and the endothelium. We can see these complications too often at our everyday work. The purpose of this paper is to draw attention to the potential complications due to inappropriate use of contact lenses.Contact lenses are otherwise a safe and effective method of correcting visual acuity; they are also useful for therapeutic purposes. Complications related to contact lenses wear could be largely avoided with an appropriate professional approach and the compliance of contact lens wearers. It is important to discuss with patients their medical history, their desires and expectations, their working and living environment; followed by professional examination of patients and appropriate fitting of contact lenses. Patients should receive detailed oral and written instructions and be subscribed to regular checks. But unfortunately, all this is not enough, if patients do not comply every day with given instructions.
Contact Estimation in Robot Interaction
Directory of Open Access Journals (Sweden)
Filippo D'Ippolito
2014-07-01
Full Text Available In the paper, safety issues are examined in a scenario in which a robot manipulator and a human perform the same task in the same workspace. During the task execution, the human should be able to physically interact with the robot, and in this case an estimation algorithm for both interaction forces and a contact point is proposed in order to guarantee safety conditions. The method, starting from residual joint torque estimation, allows both direct and adaptive computation of the contact point and force, based on a principle of equivalence of the contact forces. At the same time, all the unintended contacts must be avoided, and a suitable post-collision strategy is considered to move the robot away from the collision area or else to reduce impact effects. Proper experimental tests have demonstrated the applicability in practice of both the post-impact strategy and the estimation algorithms; furthermore, experiments demonstrate the different behaviour resulting from the adaptation of the contact point as opposed to direct calculation.
Contact Dermatitis for the Practicing Allergist.
Bernstein, David I
2015-01-01
This article provides an overview of important practice recommendations from the recently updated Contact Dermatitis Practice Parameter. This updated parameter provides essential recommendations pertaining to clinical history, physical examination, and patch testing evaluation of patients suspected of allergic contact dermatitis. In addition to providing guidance for performing and interpreting closed patch testing, the updated parameter provides concrete recommendations for assessing metal hypersensitivity in patients receiving prosthetic devices, for evaluating workers with occupational contact dermatitis, and also for addressing allergic contact dermatitis in children. Finally, the document provides practical recommendations useful for educating patients regarding avoidance of exposure to known contact sensitizers in the home and at work. The Contact Dermatitis Parameter is designed as a practical, evidence-based clinical tool to be used by allergists and dermatologists who routinely are called upon to evaluate patients with skin disorders. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Influence of interfacial layer on contact resistance
Roy, D.; In 't Zand, M.A.A.; Delhounge, R.; Klootwijk, J.H.; Wolters, Robertus A.M.
2008-01-01
The contact resistance between two materials is dependent on the intrinsic properties of the materials in contact and the presence and properties of an interfacial layer at the contact. This article presents the difference in contact resistance measurements with and without the presence of a process
Inferring epidemic contact structure from phylogenetic trees.
Directory of Open Access Journals (Sweden)
Gabriel E Leventhal
Full Text Available Contact structure is believed to have a large impact on epidemic spreading and consequently using networks to model such contact structure continues to gain interest in epidemiology. However, detailed knowledge of the exact contact structure underlying real epidemics is limited. Here we address the question whether the structure of the contact network leaves a detectable genetic fingerprint in the pathogen population. To this end we compare phylogenies generated by disease outbreaks in simulated populations with different types of contact networks. We find that the shape of these phylogenies strongly depends on contact structure. In particular, measures of tree imbalance allow us to quantify to what extent the contact structure underlying an epidemic deviates from a null model contact network and illustrate this in the case of random mixing. Using a phylogeny from the Swiss HIV epidemic, we show that this epidemic has a significantly more unbalanced tree than would be expected from random mixing.
Reimer, Nils Karl; Becker, Julia C; Benz, Angelika; Christ, Oliver; Dhont, Kristof; Klocke, Ulrich; Neji, Sybille; Rychlowska, Magdalena; Schmid, Katharina; Hewstone, Miles
2017-01-01
Previous research has shown that (a) positive intergroup contact with an advantaged group can discourage collective action among disadvantaged-group members and (b) positive intergroup contact can encourage advantaged-group members to take action on behalf of disadvantaged outgroups. Two studies investigated the effects of negative as well as positive intergroup contact. Study 1 ( n = 482) found that negative but not positive contact with heterosexual people was associated with sexual-minority students' engagement in collective action (via group identification and perceived discrimination). Among heterosexual students, positive and negative contacts were associated with, respectively, more and less LGB (lesbian, gay, bisexual) activism. Study 2 ( N = 1,469) found that only negative contact (via perceived discrimination) predicted LGBT (lesbian, gay, bisexual, and transgender) students' collective action intentions longitudinally while only positive contact predicted heterosexual/cisgender students' LGBT activism. Implications for the relationship between intergroup contact, collective action, and social change are discussed.
Soft-contact-lenses-induced complications
Directory of Open Access Journals (Sweden)
Suvajac Gordana
2008-01-01
Full Text Available Background/Aim. Soft contact lenses occupy significant place in ophthalmology, both in the correction of refraction anomalies and in the treatment of many eye diseases. The number of patients that wear soft contact lenses for the purpose of correcting ametropia is constantly increasing. Due to the increasing number of wearers, the percentage of complications that can lead to serious eye damage and serious vision loss is also increasing. The aim of this study was to point out the most common complications related to soft contact lens use. Methods. In the period from 1995−2004 this prospective study included 510 patients wearing soft contact lenses for correcting ametropia. None of the patients wore contact lenses before and none suffered from any system or local diseases that could affected the development of eventual complications. The study took seven years with the patients who wore conventional lenses and three years with those who wore replacement contact lenses. All the necessary ophthalmologic examinations were done (visual acuity, refractokeratometry, the quantity of tear film, biomicroscopic examination of anterior eye segment. All the complications were filmed by video camera. Results. Of all the patients, 19 had blepharitis, 73 suffered from “dry eye”, 57 had conjunctival hyperemia, 12 had conjunctivitis, 34 had gigantopapillary conjunctivitis (GPC, 93 had punctiform epitheliopathy, 20 had corneal infiltration, one patient had keratitis, 91 had corneal vascularisation, and 95 patients had corneal deposits. Conclusion. Both the type and frequency of complications related to soft contact lens use in our group of patients, proved to be significant. Some of this complications (keratitis can significantly damage vision and lead to loss of vision and sometimes can require operative treatment.
Response function of a moving contact line
Perrin, H.; Belardinelli, D.; Sbragaglia, M.; Andreotti, B.
2018-04-01
The hydrodynamics of a liquid-vapor interface in contact with a heterogeneous surface is largely impacted by the presence of defects at the smaller scales. Such defects introduce morphological disturbances on the contact line and ultimately determine the force exerted on the wedge of liquid in contact with the surface. From the mathematical point of view, defects introduce perturbation modes, whose space-time evolution is governed by the interfacial hydrodynamic equations of the contact line. In this paper we derive the response function of the contact line to such generic perturbations. The contact line response may be used to design simplified one-dimensional time-dependent models accounting for the complexity of interfacial flows coupled to nanoscale defects, yet offering a more tractable mathematical framework to explore contact line motion through a disordered energy landscape.
1/4-pinched contact sphere theorem
DEFF Research Database (Denmark)
Ge, Jian; Huang, Yang
2016-01-01
Given a closed contact 3-manifold with a compatible Riemannian metric, we show that if the sectional curvature is 1/4-pinched, then the contact structure is universally tight. This result improves the Contact Sphere Theorem in [EKM12], where a 4/9-pinching constant was imposed. Some tightness...
Port-contact systems in bilateral telemanipulation
Secchi, C; Stramigioli, Stefano; Fantuzzi, C.
2007-01-01
In this paper we develop one of the first control applications of the recently proposed port-contact framework. We show how it is possible to model and control a bilateral telemanipulation system using port-contact systems and we develop a port-contact impedance controller that allows to impose a
MXLKID: a maximum likelihood parameter identifier
International Nuclear Information System (INIS)
Gavel, D.T.
1980-07-01
MXLKID (MaXimum LiKelihood IDentifier) is a computer program designed to identify unknown parameters in a nonlinear dynamic system. Using noisy measurement data from the system, the maximum likelihood identifier computes a likelihood function (LF). Identification of system parameters is accomplished by maximizing the LF with respect to the parameters. The main body of this report briefly summarizes the maximum likelihood technique and gives instructions and examples for running the MXLKID program. MXLKID is implemented LRLTRAN on the CDC7600 computer at LLNL. A detailed mathematical description of the algorithm is given in the appendices. 24 figures, 6 tables
Spreading depression analysis of contact behaviour of rats.
Tikal, K
1977-08-01
Social contact behaviour induced by spreading cortical depression was studied in rats. The controls looked for and remained in contact, whereas between the rats with spreading cortical depression and their other partners there was no contact. This phenomenon is due mainly to the absence of an active urge for contact. The contact behaviour of rats is evidently controlled by the cerebral cortex or by subcortical areas of the brain which are inhibited after the elicitation of spreading depression. The experiments show that the contact behaviour of rats has at least two components - an active urge for contact and passive tolerance of contact.
Scalable algorithms for contact problems
Dostál, Zdeněk; Sadowská, Marie; Vondrák, Vít
2016-01-01
This book presents a comprehensive and self-contained treatment of the authors’ newly developed scalable algorithms for the solutions of multibody contact problems of linear elasticity. The brand new feature of these algorithms is theoretically supported numerical scalability and parallel scalability demonstrated on problems discretized by billions of degrees of freedom. The theory supports solving multibody frictionless contact problems, contact problems with possibly orthotropic Tresca’s friction, and transient contact problems. It covers BEM discretization, jumping coefficients, floating bodies, mortar non-penetration conditions, etc. The exposition is divided into four parts, the first of which reviews appropriate facets of linear algebra, optimization, and analysis. The most important algorithms and optimality results are presented in the third part of the volume. The presentation is complete, including continuous formulation, discretization, decomposition, optimality results, and numerical experimen...
Effect of corneal cross-linking on contact lens tolerance in keratoconus.
Ünlü, Metin; Yüksel, Erdem; Bilgihan, Kamil
2017-07-01
The aim was to investigate changes in corneal sensation and rigid gas-permeable (RGP) contact lens tolerance after corneal cross-linking (CXL) on patients with keratoconus. Thirty eyes of 30 patients, who were RGP lens intolerant, were treated with CXL. The main outcome measures were corneal sensation evaluation by Cochet-Bonnet esthesiometry, sub-basal nerve fibre assessment by corneal in vivo confocal microscopy and RGP contact lens tolerance evaluation with the Likert scale and wearing time. All eyes were evaluated preoperatively and post-operatively at one, three and six months after CXL procedure. The mean age was 25.3 ± 6.2 years. Preoperatively, the maximum keratometry (Kmax) in study eyes was 56.89 ± 4.60 D. Six months after CXL, it reduced to 56.03 ± 4.85 D (p = 0.01). Preoperative mean corneal sensation was 0.44 ± 0.05 g/mm 2 , (range: 0.40 to 0.55); it was significantly decreased at the first month and increased to preoperative values after six months. The sub-basal nerve plexus could not be visualised in 90 per cent of the patients by confocal microscopy at one month post-operatively. Gradual restoration of corneal innervation with almost similar preoperative levels at post-operative month six was noted. There were significant differences in Likert scores between preoperative and third and sixth months after CXL. Likert scale scores correlated significantly with corneal sensitivity. It can be concluded that increased RGP contact lens tolerance after CXL may be associated with the potential role of decreased corneal sensitivity and corneal flattening after CXL. © 2016 Optometry Australia.
Iliev, Stanimir; Pesheva, Nina; Iliev, Pavel
2018-04-01
We report here on the contact angle hysteresis, appearing when a liquid meniscus is in contact with doubly sinusoidal wavelike patterned surfaces in Wenzel's wetting regime. Using the full capillary model we obtain numerically the contact angle hysteresis as a function of the surface roughness factor and the equilibrium contact angle for a block case and a kink case contact line depinning mechanism. We find that the dependencies of the contact angle hysteresis on the surface roughness factor are different for the different contact line depinning mechanisms. These dependencies are different also for the two types of rough surfaces we studied. The relations between advancing, receding, and equilibrium contact angles are investigated. A comparison with the existing asymptotical, numerical, and experimental results is carried out.
[Determination of joint contact area using MRI].
Yoshida, Hidenori; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji
2009-10-20
Elevated contact stress on the articular joints has been hypothesized to contribute to articular cartilage wear and joint pain. However, given the limitations of using contact stress and areas from human cadaver specimens to estimate articular joint stress, there is need for an in vivo method to obtain such data. Magnetic resonance imaging (MRI) has been shown to be a valid method of quantifying the human joint contact area, indicating the potential for in vivo assessment. The purpose of this study was to describe a method of quantifying the tibiofemoral joint contact area using MRI. The validity of this technique was established in porcine cadaver specimens by comparing the contact area obtained from MRI with the contact area obtained using pressure-sensitive film (PSF). In particular, we assessed the actual condition of contact by using the ratio of signal intensity of MR images of cartilage surfaces. Two fresh porcine cadaver knees were used. A custom loading apparatus was designed to apply a compressive load to the tibiofemoral joint. We measured the contact area by using MRI and PSF methods. When the ratio of signal intensity of the cartilage surface was 0.9, the error of the contact area between the MR image and PSF was about 6%. These results suggest that this MRI method may be a valuable tool in quantifying joint contact area in vivo.
Determination of joint contact area using MRI
International Nuclear Information System (INIS)
Yoshida, Hidenori; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji
2009-01-01
Elevated contact stress on the articular joints has been hypothesized to contribute to articular cartilage wear and joint pain. However, given the limitations of using contact stress and areas from human cadaver specimens to estimate articular joint stress, there is need for an in vivo method to obtain such data. Magnetic resonance imaging (MRI) has been shown to be a valid method of quantifying the human joint contact area, indicating the potential for in vivo assessment. The purpose of this study was to describe a method of quantifying the tibiofemoral joint contact area using MRI. The validity of this technique was established in porcine cadaver specimens by comparing the contact area obtained from MRI with the contact area obtained using pressure-sensitive film (PSF). In particular, we assessed the actual condition of contact by using the ratio of signal intensity of MR images of cartilage surfaces. Two fresh porcine cadaver knees were used. A custom loading apparatus was designed to apply a compressive load to the tibiofemoral joint. We measured the contact area by using MRI and PSF methods. When the ratio of signal intensity of the cartilage surface was 0.9, the error of the contact area between the MR image and PSF was about 6%. These results suggest that this MRI method may be a valuable tool in quantifying joint contact area in vivo. (author)
DEFF Research Database (Denmark)
Jacobsen, Kåre Wedel; Falkenberg, Jesper Toft; Papior, Nick Rübner
2016-01-01
Using ab-initio methods we investigate the possibility of three-terminalgraphene "T-junction" devices and show that these all-graphene edge contactsare energetically feasible when the 1D interface itself is free from foreignatoms. We examine the energetics of various junction structures as a func......Using ab-initio methods we investigate the possibility of three-terminalgraphene "T-junction" devices and show that these all-graphene edge contactsare energetically feasible when the 1D interface itself is free from foreignatoms. We examine the energetics of various junction structures...... to be in therange of 1-10 kΩμm which is comparable to the best contact resistance reportedfor edge-contacted graphene-metal contacts. We conclude that conductingall-carbon T-junctions should be feasible....
Directory of Open Access Journals (Sweden)
Hortance Manda
Full Text Available BACKGROUND: Previous studies have demonstrated contact irritant and spatial repellent behaviors in Aedes aegypti following exposure to sublethal concentrations of chemicals. These sublethal actions are currently being evaluated in the development of a push-pull strategy for Ae. aegypti control. This study reports on mosquito escape responses after exposure to candidate chemicals for a contact irritant focused push-pull strategy using varying concentrations and focal application. METHODS: Contact irritancy (escape behavior, knockdown and 24 hour mortality rates were quantified in populations of female Ae. aegypti under laboratory conditions and validated in the field (Thailand and Peru using experimental huts. Evaluations were conducted using varying concentrations and treatment surface area coverage (SAC of three pyrethroid insecticides: alphacypermethrin, lambacyhalothrin and deltamethrin. RESULTS: Under laboratory conditions, exposure of Ae. aegypti to alphacypermethrin using the standard field application rate (FAR resulted in escape responses at 25% and 50% SAC that were comparable with escape responses at 100% SAC. Significant escape responses were also observed at <100% SAC using ½FAR of all test compounds. In most trials, KD and 24 hour mortality rates were higher in mosquitoes that did not escape than in those that escaped. In Thailand, field validation studies indicated an early time of exit (by four hours and 40% increase in escape using ½FAR of alphacypermethrin at 75% SAC compared to a matched chemical-free control. In Peru, however, the maximum increase in Ae. aegypti escape from alphacypermethrin-treated huts was 11%. CONCLUSIONS/SIGNIFICANCE: Results presented here suggest a potential role for sublethal and focal application of contact irritant chemicals in an Ae. aegypti push-pull strategy to reduce human-vector contact inside treated homes. However, the impact of an increase in escape response on dengue virus transmission is
Nöremark, Maria; Widgren, Stefan
2014-03-17
During outbreak of livestock diseases, contact tracing can be an important part of disease control. Animal movements can also be of relevance for risk-based surveillance and sampling, i.e. both when assessing consequences of introduction or likelihood of introduction. In many countries, animal movement data are collected with one of the major objectives to enable contact tracing. However, often an analytical step is needed to retrieve appropriate information for contact tracing or surveillance. In this study, an open source tool was developed to structure livestock movement data to facilitate contact-tracing in real time during disease outbreaks and for input in risk-based surveillance and sampling. The tool, EpiContactTrace, was written in the R-language and uses the network parameters in-degree, out-degree, ingoing contact chain and outgoing contact chain (also called infection chain), which are relevant for forward and backward tracing respectively. The time-frames for backward and forward tracing can be specified independently and search can be done on one farm at a time or for all farms within the dataset. Different outputs are available; datasets with network measures, contacts visualised in a map and automatically generated reports for each farm either in HTML or PDF-format intended for the end-users, i.e. the veterinary authorities, regional disease control officers and field-veterinarians. EpiContactTrace is available as an R-package at the R-project website (http://cran.r-project.org/web/packages/EpiContactTrace/). We believe this tool can help in disease control since it rapidly can structure essential contact information from large datasets. The reproducible reports make this tool robust and independent of manual compilation of data. The open source makes it accessible and easily adaptable for different needs.
Directory of Open Access Journals (Sweden)
Rossana Mastrandrea
Full Text Available Given their importance in shaping social networks and determining how information or transmissible diseases propagate in a population, interactions between individuals are the subject of many data collection efforts. To this aim, different methods are commonly used, ranging from diaries and surveys to decentralised infrastructures based on wearable sensors. These methods have each advantages and limitations but are rarely compared in a given setting. Moreover, as surveys targeting friendship relations might suffer less from memory biases than contact diaries, it is interesting to explore how actual contact patterns occurring in day-to-day life compare with friendship relations and with online social links. Here we make progresses in these directions by leveraging data collected in a French high school and concerning (i face-to-face contacts measured by two concurrent methods, namely wearable sensors and contact diaries, (ii self-reported friendship surveys, and (iii online social links. We compare the resulting data sets and find that most short contacts are not reported in diaries while long contacts have a large reporting probability, and that the durations of contacts tend to be overestimated in the diaries. Moreover, measured contacts corresponding to reported friendship can have durations of any length but all long contacts do correspond to a reported friendship. On the contrary, online links that are not also reported in the friendship survey correspond to short face-to-face contacts, highlighting the difference of nature between reported friendships and online links. Diaries and surveys suffer moreover from a low sampling rate, as many students did not fill them, showing that the sensor-based platform had a higher acceptability. We also show that, despite the biases of diaries and surveys, the overall structure of the contact network, as quantified by the mixing patterns between classes, is correctly captured by both networks of self
Mastrandrea, Rossana; Fournet, Julie; Barrat, Alain
2015-01-01
Given their importance in shaping social networks and determining how information or transmissible diseases propagate in a population, interactions between individuals are the subject of many data collection efforts. To this aim, different methods are commonly used, ranging from diaries and surveys to decentralised infrastructures based on wearable sensors. These methods have each advantages and limitations but are rarely compared in a given setting. Moreover, as surveys targeting friendship relations might suffer less from memory biases than contact diaries, it is interesting to explore how actual contact patterns occurring in day-to-day life compare with friendship relations and with online social links. Here we make progresses in these directions by leveraging data collected in a French high school and concerning (i) face-to-face contacts measured by two concurrent methods, namely wearable sensors and contact diaries, (ii) self-reported friendship surveys, and (iii) online social links. We compare the resulting data sets and find that most short contacts are not reported in diaries while long contacts have a large reporting probability, and that the durations of contacts tend to be overestimated in the diaries. Moreover, measured contacts corresponding to reported friendship can have durations of any length but all long contacts do correspond to a reported friendship. On the contrary, online links that are not also reported in the friendship survey correspond to short face-to-face contacts, highlighting the difference of nature between reported friendships and online links. Diaries and surveys suffer moreover from a low sampling rate, as many students did not fill them, showing that the sensor-based platform had a higher acceptability. We also show that, despite the biases of diaries and surveys, the overall structure of the contact network, as quantified by the mixing patterns between classes, is correctly captured by both networks of self-reported contacts and
Pizza makers' contact dermatitis.
Lembo, Serena; Lembo, Claudio; Patruno, Cataldo; Balato, Anna; Balato, Nicola; Ayala, Fabio
2014-01-01
Contact eczema to foods, spices, and food additives can occur in occupational and nonoccupational settings in those who grow, handle, prepare, or cook food. Pizza is one of the most eaten foods in every continent, and pizza making is a common work in many countries. We aimed to evaluate the occurrence and the causes of contact dermatitis in pizza makers in Naples. We performed an observational study in 45 pizza makers: all the enrolled subjects had to answer a questionnaire designed to detect personal history of respiratory or cutaneous allergy, atopy; work characteristics and timing were also investigated. Every subject attended the dermatology clinic for a complete skin examination, and when needed, patients were patch tested using the Italian baseline series of haptens integrated with an arbitrary pizza makers series. Our results reported that 13.3% of the enrolled pizza makers (6/45) presented hand eczema, and that 8.9% (4/45) were affected by occupational allergic contact dermatitis. Diallyl disulfide and ammonium persulfate were the responsible substances. Performing patch tests in pizza makers and food handlers affected by hand contact dermatitis is useful. We propose a specific series of haptens for this wide working category.
Pettengill, James B; Moeller, David A
2012-09-01
The origins of hybrid zones between parapatric taxa have been of particular interest for understanding the evolution of reproductive isolation and the geographic context of species divergence. One challenge has been to distinguish between allopatric divergence (followed by secondary contact) versus primary intergradation (parapatric speciation) as alternative divergence histories. Here, we use complementary phylogeographic and population genetic analyses to investigate the recent divergence of two subspecies of Clarkia xantiana and the formation of a hybrid zone within the narrow region of sympatry. We tested alternative phylogeographic models of divergence using approximate Bayesian computation (ABC) and found strong support for a secondary contact model and little support for a model allowing for gene flow throughout the divergence process (i.e. primary intergradation). Two independent methods for inferring the ancestral geography of each subspecies, one based on probabilistic character state reconstructions and the other on palaeo-distribution modelling, also support a model of divergence in allopatry and range expansion leading to secondary contact. The membership of individuals to genetic clusters suggests geographic substructure within each taxon where allopatric and sympatric samples are primarily found in separate clusters. We also observed coincidence and concordance of genetic clines across three types of molecular markers, which suggests that there is a strong barrier to gene flow. Taken together, our results provide evidence for allopatric divergence followed by range expansion leading to secondary contact. The location of refugial populations and the directionality of range expansion are consistent with expectations based on climate change since the last glacial maximum. Our approach also illustrates the utility of combining phylogeographic hypothesis testing with species distribution modelling and fine-scale population genetic analyses for inferring
[Eye contact effects: A therapeutic issue?
Baltazar, M; Conty, L
2016-12-01
The perception of a direct gaze - that is, of another individual's gaze directed at the observer that leads to eye contact - is known to influence a wide range of cognitive processes and behaviors. We stress that these effects mainly reflect positive impacts on human cognition and may thus be used as relevant tools for therapeutic purposes. In this review, we aim (1) to provide an exhaustive review of eye contact effects while discussing the limits of the dominant models used to explain these effects, (2) to illustrate the therapeutic potential of eye contact by targeting those pathologies that show both preserved gaze processing and deficits in one or several functions that are targeted by the eye contact effects, and (3) to propose concrete ways in which eye contact could be employed as a therapeutic tool. (1) We regroup the variety of eye contact effects into four categories, including memory effects, activation of prosocial behavior, positive appraisals of self and others and the enhancement of self-awareness. We emphasize that the models proposed to account for these effects have a poor predictive value and that further descriptions of these effects is needed. (2) We then emphasize that people with pathologies that affect memory, social behavior, and self and/or other appraisal, and self-awareness could benefit from eye contact effects. We focus on depression, autism and Alzheimer's disease to illustrate our proposal. To our knowledge, no anomaly of eye contact has been reported in depression. Patients suffering from Alzheimer disease, at the early and moderate stage, have been shown to maintain a normal amount of eye contact with their interlocutor. We take into account that autism is controversial regarding whether gaze processing is preserved or altered. In the first view, individuals are thought to elude or omit gazing at another's eyes while in the second, individuals are considered to not be able to process the gaze of others. We adopt the first stance
Current contact device for a superconducting magnet coil
International Nuclear Information System (INIS)
Hieronymus, H.
1987-01-01
The invention concerns a current supply device for a superconducting magnet coil to be shortcircuited, with a separating device per coil end, which contains a fixed cooled contact and a moving contact connected to a power supply device and a mechanical actuating device for closing and opening the contacts. When closing the heated contact on to the cooled contact, relatively large quantities of heat can be transferred to the cooled contact and therefore to the connected superconducting coil end and can cause normal conduction there. The invention therefore provides that the mass ratio of the cooled contact to the moving contact is at least 5:1, preferably at least 10:1, and that the cooled contact part is provided, at the end away from the contact area, with means for increasing the area, for example cooling fins and is connected to the coil end has a thermal resistance between the contact area and the coil end of at least 0.2 k/W, preferably at least 0.5 k/W per 1000 A of current to be transmitted. (orig.) [de
Directory of Open Access Journals (Sweden)
Xinge Yu
2012-06-01
Full Text Available Bottom-contact pentacene field-effect transistors were fabricated with a PMMA dielectric layer, and the air stability of the transistors was investigated. To characterize the device stability, the field-effect transistors were exposed to ambient conditions for 30 days and subsequently characterized. The degradation of electrical performance was traced to study the variation of field-effect mobility, saturation current and off-state current. By investigating the morphology variance of the pentacene film at the channel and source/drain (S/D contact regions by atomic force microscopy, it was clear that the morphology of the pentacene film adhered to the S/D degenerated dramatically. Moreover, by studying the variation of contact resistance in detail, it was found that the S/D contact effect was the main reason for the degradation in performance.
Applications of contact predictions to structural biology
Directory of Open Access Journals (Sweden)
Felix Simkovic
2017-05-01
Full Text Available Evolutionary pressure on residue interactions, intramolecular or intermolecular, that are important for protein structure or function can lead to covariance between the two positions. Recent methodological advances allow much more accurate contact predictions to be derived from this evolutionary covariance signal. The practical application of contact predictions has largely been confined to structural bioinformatics, yet, as this work seeks to demonstrate, the data can be of enormous value to the structural biologist working in X-ray crystallography, cryo-EM or NMR. Integrative structural bioinformatics packages such as Rosetta can already exploit contact predictions in a variety of ways. The contribution of contact predictions begins at construct design, where structural domains may need to be expressed separately and contact predictions can help to predict domain limits. Structure solution by molecular replacement (MR benefits from contact predictions in diverse ways: in difficult cases, more accurate search models can be constructed using ab initio modelling when predictions are available, while intermolecular contact predictions can allow the construction of larger, oligomeric search models. Furthermore, MR using supersecondary motifs or large-scale screens against the PDB can exploit information, such as the parallel or antiparallel nature of any β-strand pairing in the target, that can be inferred from contact predictions. Contact information will be particularly valuable in the determination of lower resolution structures by helping to assign sequence register. In large complexes, contact information may allow the identity of a protein responsible for a certain region of density to be determined and then assist in the orientation of an available model within that density. In NMR, predicted contacts can provide long-range information to extend the upper size limit of the technique in a manner analogous but complementary to experimental
Definition and detection of contact in atomistic simulations
Solhjoo, Soheil; Vakis, Antonis I.
In atomistic simulations, contact depends on the accurate detection of contacting atoms as well as their contact area. While it is common to define contact between atoms based on the so-called ‘contact distance’ where the interatomic potential energy reaches its minimum, this discounts, for example,
Definition and detection of contact in atomistic simulations
Solhjoo, Soheil; Vakis, Antonis I.
2015-01-01
In atomistic simulations, contact depends on the accurate detection of contacting atoms as well as their contact area. While it is common to define contact between atoms based on the so-called ‘contact distance’ where the interatomic potential energy reaches its minimum, this discounts, for example,
Nordic project food contact materials
DEFF Research Database (Denmark)
Li, Ågot; Tesdal Håland, Julie; Petersen, Jens Højslev
Denmark, Finland, Faroe Islands, Iceland, Norway and Sweden have in 2013––2015 conducted a Nordic project on food contact materials. Food contact materials are used in all stages of food production and can be a general source of contamination. The food safety authorities in most of the Nordic...... countries have had a limited focus on the FCM area with the exception of Denmark and Finland. The aim of the project was therefore to control establishments producing, importing or using plastic food contact materials as well as to increase the knowledge of the inspectors performing these controls....... The focus of the inspections was to control the declaration of compliance (DoC) for plastic food contact materials. The requirement for a Doc is mandatory in order to ensure that the FCM complies with the legislation. In addition some products were analyzed for phthalates....
A ROSAT Survey of Contact Binary Stars
Geske, M. T.; Gettel, S. J.; McKay, T. A.
2006-01-01
Contact binary stars are common variable stars that are all believed to emit relatively large fluxes of X-rays. In this work we combine a large new sample of contact binary stars derived from the ROTSE-I telescope with X-ray data from the ROSAT All Sky Survey (RASS) to estimate the X-ray volume emissivity of contact binary stars in the Galaxy. We obtained X-ray fluxes for 140 contact binaries from the RASS, as well as two additional stars observed by the XMM-Newton observatory. From these data we confirm the emission of X-rays from all contact binary systems, with typical luminosities of approximately 1.0×1030 ergs s-1. Combining calculated luminosities with an estimated contact binary space density, we find that contact binaries do not have strong enough X-ray emission to account for a significant portion of the Galactic X-ray background.
Allergic contact dermatitis to plastic banknotes.
Mohamed, M; Delaney, T A; Horton, J J
1999-08-01
Allergic contact dermatitis to ultraviolet (UV) cured acrylates occurs predominantly in occupationally exposed workers. Two men presented with dermatitis coinciding with the location of banknotes in their pockets. Patch testing confirmed allergic contact dermatitis to multiple acrylates and Australian plastic banknotes. This is the first report of contact allergy to acrylates present in Australian plastic banknotes.
Fusaro, R. L.
1981-01-01
A pin-on-disk type of friction and wear apparatus was used to study the effect of load, contact stress and rider area of contact on the friction and wear properties of polyimide-bonded graphite fluoride films. Different rider area contacts were obtained by initially generating flats (with areas of 0.0035, 0.0071, 0.0145, and 0.0240 cm) on 0.476-cm radius hemispherically-tipped riders. Different projected contact stresses were obtained by applying loads of 2.5-to 58.8-N to the flats. Two film wear mechanisms were observed. The first was found to be a linear function of contact stress and was independent of rider area of contact. The second was found to increase exponentially as the stress increased. The second also appeared to be a function of rider contact area. Wear equations for each mechanism were empirically derived from the experimental data. In general, friction coefficients increased with increasing rider contact area and with sliding duration. This was related to the build-up of thick rider transfer films.
Fusaro, R. L.
1980-01-01
A pin on disk type of friction and wear apparatus was used to study the effect of load, contact stress and rider area of contact on the friction and wear properties of polyimide bonded graphite fluoride films. Different rider area contacts were obtained by initially generating flats (with areas of 0.0035, 0.0071, 0.0145, and 0.0240 cm) on 0.476-cm radius hemispherically tipped riders. Different projected contact stresses were obtained by applying loads of 2.5- to 58.8-N to the flats. Two film wear mechanisms were observed. The first was found to be a linear function of contact stress and was independent of rider area of contact. The second was found to increase exponentially as the stress increased. The second also appeared to be a function of rider contact area. Wear equations for each mechanism were empirically derived from the experimental data. In general, friction coefficients increased with increasing rider contact area and with sliding duration. This was related to the build up of thick rider transfer films.
Characteristics of molybdenum bilayer back contacts for Cu(In,Ga)Se{sub 2} solar cells on Ti foils
Energy Technology Data Exchange (ETDEWEB)
Roger, Charles, E-mail: charles.rgr@gmail.com [CEA, LITEN, 17 Rue des Martyrs, 38054 Grenoble Cedex 9 (France); Noël, Sébastien; Sicardy, Olivier; Faucherand, Pascal; Grenet, Louis; Karst, Nicolas; Fournier, Hélène; Roux, Frédéric [CEA, LITEN, 17 Rue des Martyrs, 38054 Grenoble Cedex 9 (France); Ducroquet, Frédérique [IMEP-LAHC, Minatec, Grenoble-INP, CNRS UMR 5130, 38016 Grenoble (France); Brioude, Arnaud [Laboratoire des Multimatériaux et Interfaces, UMR 5615, Villeurbanne (France); Perraud, Simon [CEA, LITEN, 17 Rue des Martyrs, 38054 Grenoble Cedex 9 (France)
2013-12-02
Molybdenum back contact properties are critical for Cu(In,Ga)Se{sub 2} (CIGS) solar cell performance on metallic substrates. In this work, we investigated the properties of sputter-deposited Mo bilayer back contacts on Ti foils. The morphology, electrical resistivity, optical reflectance and residual mechanical stress of the bottom Mo layer were modified by varying the working pressure during its deposition. Working pressures ranging from 0.27 Pa to 4.00 Pa were used. The top Mo layer was deposited using constant conditions at a pressure of 0.13 Pa. It was demonstrated that unlike a Mo monolayer, the use of a Mo bilayer allows controlling the mechanical stress at the Mo/CIGS interface without degrading the optical reflectance and the electrical resistance of the back contact. It was also found that the morphology of the bottom Mo layer affects the growth of the top Mo layer, resulting in a modified back contact surface morphology. This induces changes in the crystalline orientation of the CIGS layer. The resulting solar cell characteristics strongly vary as a function of the bottom Mo layer deposition pressure. A bottom Mo layer growth at 2.93 Pa allows improving the solar cell conversion efficiency by 1.5 times compared to a bottom Mo layer deposited at 0.27 Pa. Using the improved Mo bilayer back contact, a maximum solar cell efficiency of 10.0% was obtained without sodium addition nor anti-reflection coating. - Highlights: • Mo bilayer back contacts for Cu(In,Ga)Se{sub 2} solar cells were grown on Ti substrates. • The sputtering pressure of the bottom Mo layer was varied between 0.27 Pa and 4 Pa. • The top Mo layer controls the optical and electrical properties of the back contact. • The structure of the bottom Mo layer influences the morphology of the top Mo layer. • The back contact affects the CIGS texture, device series resistance and efficiency.
Eye contact and Cross-cultural Communication
Institute of Scientific and Technical Information of China (English)
刘西娟
2009-01-01
It is commonly agreed by contemporary schohrs that it is important to understand the role of culture and its characteristics and potential impact on individuals engaged in cross-cultural communication.Nonverbal Communication often reveals basic culture traits.Eye contact,as a mediunq to convey emodon.attitudes and intention.phys an undeniably vital role in communication.The concentration of this paper is to discuss the functions of eye contact in communication,different information conveyed by eve contact on the basis of different cultures and the importance of understanding and respecting the rituals of eye contact in cross-culmral communication.
Emotional Satisfaction of Customer Contacts
Güngör, Hüseyin
2007-01-01
For marketing and customer services researchers and professionals who are interested in customer contacts, customer satisfaction and loyalty issues. Contact centers are playing a pivotal role in customer services of the 21st century. Nevertheless, despite their growing importance and presence,
2013-02-12
... maximum penalty amount of $75,000 for each violation, except that if the violation results in death... the maximum civil penalty for a violation is $175,000 if the violation results in death, serious... Penalties for a Violation of the Hazardous Materials Transportation Laws or Regulations, Orders, Special...
Im, K. H.; Chang, M.; Hsu, D. K.; Song, S. J.; Cho, H.; Park, J. W.; Kweon, Y. S.; Sim, J. K.; Yang, I. Y.
2007-03-01
Advanced materials are to be required to have specific functions associated with extremely environments. One of them is carbon/carbon(C/C) composite material, which has obvious advantages over conventional materials. The C/Cs have become to be utilized as parts of aerospace applications and its low density, high thermal conductivity and excellent mechanical properties at elevated temperatures make it an ideal material for aircraft brake disks. Because of permeation of coupling medium such as water, it is desirable to perform contact-less nondestructive evaluation to assess material properties and part homogeneity. In this work, a C/C composite material was characterized with non-contact and contact ultrasonic methods using a scanner with automatic-data acquisition function. Also through transmission mode was performed because of the main limitation for air-coupled transducers, which is the acoustic impedance mismatch between most materials and air. Especially ultrasonic images and velocities for C/C composite disk brake were compared and found to be consistent to some degree with the non-contact and contact ultrasonic measurement methods. Low frequency through-transmission scans based on both amplitude of the ultrasonic pulse was used for mapping out the material property inhomogeneity. Measured results were compared with those obtained by the dry-coupling ultrasonic UT system and through transmission method in immersion. Finally, feasibility has been found to measure and compare ultrasonic velocities of C/C composites with using the contact/noncontact peak-delay measurement method based on the pulse overlap method.
Fuentes, Aler D; Sforza, Chiarella; Miralles, Rodolfo; Ferreira, Cláudia L; Mapelli, Andrea; Lodetti, Gianluigi; Martin, Conchita
2017-05-01
The aim of this study was to investigate whether the presence of a natural mediotrusive contact influences electromyographic (EMG) pattern activity in patients with temporomandibular disorders (TMDs). Bilateral surface EMG activity of the anterior temporalis (AT), masseter (MM), and sternocleidomastoid (SCM) muscles was recorded in 43 subjects during unilateral chewing and tooth grinding. Thirteen patients had TMD and a natural mediotrusive contact (Group 1), 15 had TMD without a natural mediotrusive contact (Group 2), and 15 were healthy subjects without mediotrusive contacts (Group 3). All subjects were examined according to the Research Diagnostic Criteria for TMD (RDC/TMD). All EMG values were standardized as the percentage of EMG activity recorded during maximum isometric contraction on cotton rolls. EMG activity from all muscles measured showed no significant differences between groups during chewing and grinding. Overall, in all groups, the EMG activity during chewing was higher in the working side than the non-working side in AT and MM muscles. During grinding, these differences were only found in masseter muscles (mainly in eccentric grinding). SCM EMG activity did not show significant differences during chewing and grinding tasks. Symmetry, muscular balance, and absence of lateral jaw displacement were common findings in all groups. EMG results suggest that the contribution of a natural mediotrusive occlusal contact to EMG patterns in TMD patients is minor. Therefore, the elimination of this occlusal feature for therapeutic purposes could be not indicated.
Epidemic contact tracing via communication traces.
Directory of Open Access Journals (Sweden)
Katayoun Farrahi
Full Text Available Traditional contact tracing relies on knowledge of the interpersonal network of physical interactions, where contagious outbreaks propagate. However, due to privacy constraints and noisy data assimilation, this network is generally difficult to reconstruct accurately. Communication traces obtained by mobile phones are known to be good proxies for the physical interaction network, and they may provide a valuable tool for contact tracing. Motivated by this assumption, we propose a model for contact tracing, where an infection is spreading in the physical interpersonal network, which can never be fully recovered; and contact tracing is occurring in a communication network which acts as a proxy for the first. We apply this dual model to a dataset covering 72 students over a 9 month period, for which both the physical interactions as well as the mobile communication traces are known. Our results suggest that a wide range of contact tracing strategies may significantly reduce the final size of the epidemic, by mainly affecting its peak of incidence. However, we find that for low overlap between the face-to-face and communication interaction network, contact tracing is only efficient at the beginning of the outbreak, due to rapidly increasing costs as the epidemic evolves. Overall, contact tracing via mobile phone communication traces may be a viable option to arrest contagious outbreaks.
Epidemic contact tracing via communication traces.
Farrahi, Katayoun; Emonet, Rémi; Cebrian, Manuel
2014-01-01
Traditional contact tracing relies on knowledge of the interpersonal network of physical interactions, where contagious outbreaks propagate. However, due to privacy constraints and noisy data assimilation, this network is generally difficult to reconstruct accurately. Communication traces obtained by mobile phones are known to be good proxies for the physical interaction network, and they may provide a valuable tool for contact tracing. Motivated by this assumption, we propose a model for contact tracing, where an infection is spreading in the physical interpersonal network, which can never be fully recovered; and contact tracing is occurring in a communication network which acts as a proxy for the first. We apply this dual model to a dataset covering 72 students over a 9 month period, for which both the physical interactions as well as the mobile communication traces are known. Our results suggest that a wide range of contact tracing strategies may significantly reduce the final size of the epidemic, by mainly affecting its peak of incidence. However, we find that for low overlap between the face-to-face and communication interaction network, contact tracing is only efficient at the beginning of the outbreak, due to rapidly increasing costs as the epidemic evolves. Overall, contact tracing via mobile phone communication traces may be a viable option to arrest contagious outbreaks.
Harikrishnan, A. R.; Dhar, Purbarun; Agnihotri, Prabhat K.; Gedupudi, Sateesh; Das, Sarit K.
2018-04-01
Dynamic wettability and contact angle hysteresis can be correlated to shed insight onto any solid-liquid interaction. Complex fluids are capable of altering the expected hysteresis and dynamic wetting behavior due to interfacial interactions. We report the effect of capillary number on the dynamic advancing and receding contact angles of surfactant-based nanocolloidal solutions on hydrophilic, near hydrophobic, and superhydrophobic surfaces by performing forced wetting and de-wetting experiments by employing the embedded needle method. A segregated study is performed to infer the contributing effects of the constituents and effects of particle morphology. The static contact angle hysteresis is found to be a function of particle and surfactant concentrations and greatly depends on the nature of the morphology of the particles. An order of estimate of line energy and a dynamic flow parameter called spreading factor and the transient variations of these parameters are explored which sheds light on the dynamics of contact line movement and response to perturbation of three-phase contact. The Cox-Voinov-Tanner law was found to hold for hydrophilic and a weak dependency on superhydrophobic surfaces with capillary number, and even for the complex fluids, with a varying degree of dependency for different fluids.
Effect of 3D fractal dimension on contact area and asperity interactions in elastoplastic contact
Directory of Open Access Journals (Sweden)
Abdeljalil Jourani
2016-05-01
Full Text Available Few models are devoted to investigate the effect of 3D fractal dimension Ds on contact area and asperity interactions. These models used statistical approaches or two-dimensional deterministic simulations without considering the asperity interactions and elastic–plastic transition regime. In this study, a complete 3D deterministic model is adopted to simulate the contact between fractal surfaces which are generated using a modified two-variable Weierstrass–Mandelbrot function. This model incorporates the asperity interactions and considers the different deformation modes of surface asperities which range from entirely elastic through elastic-plastic to entirely plastic contact. The simulations reveal that the elastoplastic model is more appropriate to calculate the contact area ratio and pressure field. It is also shown that the influence of the asperity interactions cannot be neglected, especially at lower fractal dimension Ds and higher load.
Contact lens rehabilitation following repaired corneal perforations
Titiyal, Jeewan S; Sinha, Rajesh; Sharma, Namrata; Sreenivas, V; Vajpayee, Rasik B
2006-01-01
Background Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. Method Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. Results Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60%) required aphakic contact lenses. The best corrected visual acuity (BCVA) of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25%) eyes with spectacle correction and 37 (92.5%) eyes with the use of contact lens (p < 0.001). The best-corrected visual acuity with spectacles was 0.20 ± 0.13 while the same with contact lens was 0.58 ± 0.26. All the patients showed an improvement of ≥ 2 lines over spectacles in the snellen's acuity chart with contact lens. Conclusion Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries. PMID:16536877
International Nuclear Information System (INIS)
Wang, P.-Y.; Hou, S.-S.
2005-01-01
In this paper, performance analysis and comparison based on the maximum power and maximum power density conditions have been conducted for an Atkinson cycle coupled to variable temperature heat reservoirs. The Atkinson cycle is internally reversible but externally irreversible, since there is external irreversibility of heat transfer during the processes of constant volume heat addition and constant pressure heat rejection. This study is based purely on classical thermodynamic analysis methodology. It should be especially emphasized that all the results and conclusions are based on classical thermodynamics. The power density, defined as the ratio of power output to maximum specific volume in the cycle, is taken as the optimization objective because it considers the effects of engine size as related to investment cost. The results show that an engine design based on maximum power density with constant effectiveness of the hot and cold side heat exchangers or constant inlet temperature ratio of the heat reservoirs will have smaller size but higher efficiency, compression ratio, expansion ratio and maximum temperature than one based on maximum power. From the view points of engine size and thermal efficiency, an engine design based on maximum power density is better than one based on maximum power conditions. However, due to the higher compression ratio and maximum temperature in the cycle, an engine design based on maximum power density conditions requires tougher materials for engine construction than one based on maximum power conditions
Measuring social contacts in the emergency department.
Directory of Open Access Journals (Sweden)
Douglas W Lowery-North
Full Text Available Infectious individuals in an emergency department (ED bring substantial risks of cross infection. Data about the complex social and spatial structure of interpersonal contacts in the ED will aid construction of biologically plausible transmission risk models that can guide cross infection control.We sought to determine the number and duration of contacts among patients and staff in a large, busy ED. This prospective study was conducted between 1 July 2009 and 30 June 2010. Two 12-hour shifts per week were randomly selected for study. The study was conducted in the ED of an urban hospital. There were 81 shifts in the planned random sample of 104 (78% with usable contact data, during which there were 9183 patient encounters. Of these, 6062 (66% were approached to participate, of which 4732 (78% agreed. Over the course of the year, 88 staff members participated (84%. A radiofrequency identification (RFID system was installed and the ED divided into 89 distinct zones structured so copresence of two individuals in any zone implied a very high probability of contact <1 meter apart in space. During study observation periods, patients and staff were given RFID tags to wear. Contact events were recorded. These were further broken down with respect to the nature of the contacts, i.e., patient with patient, patient with staff, and staff with staff. 293,171 contact events were recorded, with a median of 22 contact events and 9 contacts with distinct individuals per participant per shift. Staff-staff interactions were more numerous and longer than patient-patient or patient-staff interactions.We used RFID to quantify contacts between patients and staff in a busy ED. These results are useful for studies of the spread of infections. By understanding contact patterns most important in potential transmission, more effective prevention strategies may be implemented.
2010-02-05
... for OMB Review; National Contact Center Customer Evaluation Survey AGENCY: Citizen Services and Communications, Federal Consumer Information Center, GSA. ACTION: Notice of request for comments regarding a... collection requirement regarding the National Contact Center customer evaluation survey. A request for public...
Ohmic contacts to InN-based materials
Directory of Open Access Journals (Sweden)
Sai P. O.
2016-10-01
Full Text Available The key aspects of ohmic contact formation to InN-based materials were investigated. Detailed analysis of studies conducted over the past three decades, allows determining the basic principles of such contacts. The contact structure properties and optimal conditions for them are presented. Different types of metallization are considered, the advantages and disadvantages of each are determined, including the basic requirements that such contact must meet. There is emphasis on the using multilayer metallization with the barrier layers. In the case of the InAlN/GaN systems, the general approaches of forming ohmic contacts were considered.
Energy Technology Data Exchange (ETDEWEB)
Heland, Joerg; Rick, Frank; Sarnes, Bernhard [DB Systemtechnik GmbH, Muenchen (Germany); Puschmann, Rainer [Siemens AG, Erlangen (Germany). Infrastructure and Cities
2012-07-15
The reliable energy transmission from overhead contact line to pantograph of traction units without interruption decides on the successful operation of high-speed railway lines. Measurements of contact wire position and contact forces are suited to assess interaction of overhead contact line and pantograph. Chinese Railways actually implement the biggest electrification program for high-speed lines worldwide. For these projects contact wire position and contact forces are monitored by procedures developed in Germany. The experience confirms that keeping the contact wire position within the specified limits lead to a superior energy transmission up to 350 km/h. (orig.)
Effect of contact angle on the orientation, stability, and assembly of dense floating cubes.
Daniello, Robert; Khan, Kashan; Donnell, Michael; Rothstein, Jonathan P
2014-02-01
In this paper, the effect of contact angle, density, and size on the orientation, stability, and assembly of floating cubes was investigated. All the cubes tested were more dense than water. Floatation occurred as a result of capillary stresses induced by deformation of the air-water interface. The advancing contact angle of the bare acrylic cubes was measured to be 85°. The contact angle of the cubes was increased by painting the cubes with a commercially available superhydrophobic paint to reach an advancing contact angle of 150°. Depending on their size, density, and contact angle, the cubes were observed to float in one of three primary orientations: edge up, vertex up, and face up. An experimental apparatus was built such that the sum of the gravitational force, buoyancy force, and capillary forces could be measured using a force transducer as a function of cube position as it was lowered through the air-water interface. Measurements showed that the maximum capillary forces were always experienced for the face up orientation. However, when floatation was possible in the vertex up orientation, it was found to be the most stable cube orientation because it had the lowest center of gravity. A series of theoretical predictions were performed for the cubes floating in each of the three primary orientations to calculate the net force on the cube. The theoretical predictions were found to match the experimental measurements well. A cube stability diagram of cube orientation as a function of cube contact angle and size was prepared from the predictions of theory and found to match the experimental observations quite well. The assembly of cubes floating face up and vertex up were also studied for assemblies of two, three, and many cubes. Cubes floating face up were found to assemble face-to-face and form regular square lattice patterns with no free interface between cubes. Cubes floating vertex up were found to assemble in a variety of different arrangements
European Surveillance System on Contact Allergies (ESSCA)
DEFF Research Database (Denmark)
Uter, W; Amario-Hita, J C; Balato, A
2017-01-01
BACKGROUND: Contact allergy is a common condition and can severely interfere with daily life or professional activities. Due to changes in exposures, such as introduction of new substances, new products or formulations and regulatory intervention, the spectrum of contact sensitization changes....... OBJECTIVE: To evaluate the current spectrum of contact allergy to allergens present in the European baseline series (EBS) across Europe. METHODS: Retrospective analysis of data collected by the European Surveillance System on Contact Allergies (ESSCA, www.essca-dc.org) in consecutively patch-tested patients......, 2013/14, in 46 departments in 12 European countries. RESULTS: Altogether, 31 689 patients were included in the analysis. Compared to a similar analysis in 2004, the prevalence of contact allergy to methylisothiazolinone went up to around 20% in several departments. In comparison, contact allergy...
Contact angle measurement with a smartphone.
Chen, H; Muros-Cobos, Jesus L; Amirfazli, A
2018-03-01
In this study, a smartphone-based contact angle measurement instrument was developed. Compared with the traditional measurement instruments, this instrument has the advantage of simplicity, compact size, and portability. An automatic contact point detection algorithm was developed to allow the instrument to correctly detect the drop contact points. Two different contact angle calculation methods, Young-Laplace and polynomial fitting methods, were implemented in this instrument. The performance of this instrument was tested first with ideal synthetic drop profiles. It was shown that the accuracy of the new system with ideal synthetic drop profiles can reach 0.01% with both Young-Laplace and polynomial fitting methods. Conducting experiments to measure both static and dynamic (advancing and receding) contact angles with the developed instrument, we found that the smartphone-based instrument can provide accurate and practical measurement results as the traditional commercial instruments. The successful demonstration of use of a smartphone (mobile phone) to conduct contact angle measurement is a significant advancement in the field as it breaks the dominate mold of use of a computer and a bench bound setup for such systems since their appearance in 1980s.
Contact angle measurement with a smartphone
Chen, H.; Muros-Cobos, Jesus L.; Amirfazli, A.
2018-03-01
In this study, a smartphone-based contact angle measurement instrument was developed. Compared with the traditional measurement instruments, this instrument has the advantage of simplicity, compact size, and portability. An automatic contact point detection algorithm was developed to allow the instrument to correctly detect the drop contact points. Two different contact angle calculation methods, Young-Laplace and polynomial fitting methods, were implemented in this instrument. The performance of this instrument was tested first with ideal synthetic drop profiles. It was shown that the accuracy of the new system with ideal synthetic drop profiles can reach 0.01% with both Young-Laplace and polynomial fitting methods. Conducting experiments to measure both static and dynamic (advancing and receding) contact angles with the developed instrument, we found that the smartphone-based instrument can provide accurate and practical measurement results as the traditional commercial instruments. The successful demonstration of use of a smartphone (mobile phone) to conduct contact angle measurement is a significant advancement in the field as it breaks the dominate mold of use of a computer and a bench bound setup for such systems since their appearance in 1980s.
Occlusal factors are not related to self-reported bruxism.
Manfredini, Daniele; Visscher, Corine M; Guarda-Nardini, Luca; Lobbezoo, Frank
2012-01-01
To estimate the contribution of various occlusal features of the natural dentition that may identify self-reported bruxers compared to nonbruxers. Two age- and sex-matched groups of self-reported bruxers (n = 67) and self-reported nonbruxers (n = 75) took part in the study. For each patient, the following occlusal features were clinically assessed: retruded contact position (RCP) to intercuspal contact position (ICP) slide length ( 4 mm, a deep bite), horizontal overlap (> 4 mm was considered a large horizontal overlap), incisor dental midline discrepancy (bruxism (dependent variable). Accuracy values to predict self-reported bruxism were unacceptable for all occlusal variables. The only variable remaining in the final regression model was laterotrusive interferences (P = .030). The percentage of explained variance for bruxism by the final multiple regression model was 4.6%. This model including only one occlusal factor showed low positive (58.1%) and negative predictive values (59.7%), thus showing a poor accuracy to predict the presence of self-reported bruxism (59.2%). This investigation suggested that the contribution of occlusion to the differentiation between bruxers and nonbruxers is negligible. This finding supports theories that advocate a much diminished role for peripheral anatomical-structural factors in the pathogenesis of bruxism.
a-Si:H/c-Si heterojunction front- and back contacts for silicon solar cells with p-type base
Energy Technology Data Exchange (ETDEWEB)
Rostan, Philipp Johannes
2010-07-01
This thesis reports on low temperature amorphous silicon back and front contacts for high-efficiency crystalline silicon solar cells with a p-type base. The back contact uses a sequence of intrinsic amorphous (i-a-Si:H) and boron doped microcrystalline (p-{mu}c-Si:H) silicon layers fabricated by Plasma Enhanced Chemical Vapor Deposition (PECVD) and a magnetron sputtered ZnO:Al layer. The back contact is finished by evaporating Al onto the ZnO:Al and altogether prepared at a maximum temperature of 220 C. Analysis of the electronic transport of mobile charge carriers at the back contact shows that the two high-efficiency requirements low back contact series resistance and high quality c-Si surface passivation are in strong contradiction to each other, thus difficult to achieve at the same time. The preparation of resistance- and effective lifetime samples allows one to investigate both requirements independently. Analysis of the majority charge carrier transport on complete Al/ZnO:Al/a-Si:H/c-Si back contact structures derives the resistive properties. Measurements of the effective minority carrier lifetime on a-Si:H coated wafers determines the back contact surface passivation quality. Both high-efficiency solar cell requirements together are analyzed in complete photovoltaic devices where the back contact series resistance mainly affects the fill factor and the back contact passivation quality mainly affects the open circuit voltage. The best cell equipped with a diffused emitter with random texture and a full-area a-Si:H/c-Si back contact has an independently confirmed efficiency {eta} = 21.0 % with an open circuit voltage V{sub oc} = 681 mV and a fill factor FF = 78.7 % on an area of 1 cm{sup 2}. An alternative concept that uses a simplified a-Si:H layer sequence combined with Al-point contacts yields a confirmed efficiency {eta} = 19.3 % with an open circuit voltage V{sub oc} = 655 mV and a fill factor FF = 79.5 % on an area of 2 cm{sup 2}. Analysis of the
Directory of Open Access Journals (Sweden)
Sharma Vinod
2010-01-01
Full Text Available Allergic contact dermatitis (ACD in children, until recently, was considered rare. ACD was considered as a disorder of the adult population and children were thought to be spared due to a lack of exposure to potential allergens and an immature immune system. Prevalence of ACD to even the most common allergens in children, like poison ivy and parthenium, is relatively rare as compared to adults. However, there is now growing evidence of contact sensitization of the pediatric population, and it begins right from early childhood, including 1-week-old neonates. Vaccinations, piercing, topical medicaments and cosmetics in younger patients are potential exposures for sensitization. Nickel is the most common sensitizer in almost all studies pertaining to pediatric contact dermatitis. Other common allergens reported are cobalt, fragrance mix, rubber, lanolin, thiomersol, neomycin, gold, mercapto mix, balsum of Peru and colophony. Different factors like age, sex, atopy, social and cultural practices, habit of parents and caregivers and geographic changes affect the patterns of ACD and their variable clinical presentation. Patch testing should be considered not only in children with lesions of a morphology suggestive of ACD, but in any child with dermatitis that is difficult to control.
HARDINESS, WORLD ASSUMPTIONS, MOTIVATION OF ATHLETES OF CONTACT AND NOT CONTACT KINDS OF SPORT
Directory of Open Access Journals (Sweden)
Elena Vladimirovna Molchanova
2017-04-01
Full Text Available Investigation of personal psychological specificity of athletes of contact (freestyle wrestling and not contact (archery kinds of sport were carried out. Pronounced deviation in hardiness, world assumptions, motives for sport doing were obtained. In particularly, archery athletes possess higher values of hardiness and positively view the world, than wrestlers, while possess less motives for sport doing as “successful for life quality and skills” and “physical perfection”. Thus for athletes not contact kinds of sports rather coping in permanent stressed conditions are predicted. The obtained results are practically important for counseling work of sport psychologists and moreover they could be a basement for training teach programs and challenge stress overcoming programs.
: (505) 665-3664 ethics@lanl.gov Journalist queries Communications Office (505) 667-7000 Media contacts programs and employee resources. General Employee directory Emergency communication Communications Office (505) 667-7000 Ethics & Audits Internal Audit: (505) 665-3104 Ethics Office: (505) 667-7506 Fax
Journal of Business Research: Contact
African Journals Online (AJOL)
Principal Contact. Goski Alabi Mrs Institute of Professional Studies (IPS) P. 0 Box 149 Institute Of Professional Studies (IPS) Legon, Accra Ghana Phone: +233 24 64 52798. Fax: +233 21 513539. Email: goskia@yahoo.com. Support Contact. Anthony Afeadie. Phone: +233 21 500171. Email: ipsjournal@yahoo.com.
CONTACT LENS RELATED CORNEAL ULCER
Directory of Open Access Journals (Sweden)
AGARWAL P
2010-01-01
Full Text Available A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are:overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. The presenting symptoms of contact lens related corneal ulcers include eye discomfort, foreign body sensation and lacrimation. More serious symptoms are redness (especially circum-corneal injection, severe pain, photophobia, eye discharge and blurring of vision. The diagnosis is established by a thorough slit lamp microscopic examination with fluorescein staining and corneal scraping for Gram stain and culture of the infective organism. Delay in diagnosing and treatment can cause permanent blindness, therefore an early referral to ophthalmologist and commencing of antimicrobial therapy can prevent visual loss.
Liu, Feng; Williams, Sophie; Jin, Zhongmin; Fisher, John
2013-11-01
Head contact on the rim of the cup causes stress concentration and consequently increased wear. The head contact on the rim of the cup may in addition cause an offset load and torque on the cup. The head-rim contact resulting from microseparation or subluxation has been investigated. An analytical model has been developed to calculate the offset loading and resultant torque on the cup as a function of the translational displacement of the head under simplified loading condition of the hip joint at heel strike during a walking cycle. The magnitude of the torque on the cup was found to increase with the increasing translational displacement, larger diameter heads, eccentric cups, and the coefficient of friction of the contact. The effects of cup inclination, cup rim radius, and cup coverage angle on the magnitude of the torque were found to be relatively small with a maximum variation in the torque magnitude being lower than 20%. This study has shown an increased torque due to the head loading on the rim of the cup, and this may contribute to the incidence of cup loosening. Particularly, metal-on-metal hip joints with larger head diameters may produce the highest offset loading torque.
Marx, Sebastian; Lauenborg, Bo; Kern, Jami R
2018-02-06
To evaluate the tolerability of and subject and investigator satisfaction with delefilcon A (DAILIES TOTAL1 ® ) daily disposable contact lenses in first-time contact lens wearers. This European multicenter, open-label, single-arm, two-week trial enrolled first-time contact lens wearers and fitted them with delefilcon A contact lenses. Assessments were made at dispensing and at Weeks 1 and 2. Subject-reported outcomes included comfort, quality of vision, convenience, and intent to purchase, which were ranked by agreement responses. Investigator-reported outcomes included slit-lamp biomicroscopy findings and lens fit satisfaction. Ninety-two subjects were included in the per protocol dataset. Mean scores at Weeks 1 and 2 for subject-reported quality of vision and ocular comfort were significantly higher with delefilcon A contact lenses than with the subjects' habitual spectacles during the day, at the end of the day, and overall (all p ≤ 0.02). Ninety-one percent of subjects reported that their study lenses were more comfortable than expected, 98% agreed that they were convenient to use, and 92% were interested in purchasing the lenses (all p disposable contact lenses. Copyright © 2017. Published by Elsevier Ltd.
Lithium-drifted silicon detector with segmented contacts
Tindall, Craig S.; Luke, Paul N.
2006-06-13
A method and apparatus for creating both segmented and unsegmented radiation detectors which can operate at room temperature. The devices include a metal contact layer, and an n-type blocking contact formed from a thin layer of amorphous semiconductor. In one embodiment the material beneath the n-type contact is n-type material, such as lithium compensated silicon that forms the active region of the device. The active layer has been compensated to a degree at which the device may be fully depleted at low bias voltages. A p-type blocking contact layer, or a p-type donor material can be formed beneath a second metal contact layer to complete the device structure. When the contacts to the device are segmented, the device is capable of position sensitive detection and spectroscopy of ionizing radiation, such as photons, electrons, and ions.
Variable reluctance switch avoids contact corrosion and contact bounce
Watson, P. C.
1967-01-01
Variable reluctance switch avoids contact corrosion and bounce in a hostile environment. It consists of a wire-wound magnetic core and moveable bridge piece that alters the core flux pattern to produce an electrical output useful for switching control media.
Biomechanical analysis of the contact phase in drop jumps performed in water and on dry land
Directory of Open Access Journals (Sweden)
Caroline Ruschel
2016-03-01
Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2016v18n1p41 Plyometric training in the aquatic environment has been used as way of reducing loads through the action of buoyancy. However, little is known about the biomechanical characteristics of plyometric exercises in water, which can assist in the prescription of training in this environment. This study aimed to analyze the vertical component of the ground reaction force and contact duration of drop jumps (DJ performed on land and at hip level water immersion. Participants were 22 male athletes (19.1 ± 3.7 years, who performed three maximum DJs in water and on dry land. Peak force and duration of braking and propulsion sub-phases of the DJ contact were analyzed with the use of two underwater force platforms, a 2-D waterproofed electrogoniometer, acquisition systems ADS2000-IP and TeleMyo 2400TG2, and a signal synchronizer. The effect of immersion was investigated through comparison tests for dependent samples (p <0.05. In water, the following results were observed: (a reduction of 41.8% (p <0.001, d = 2.24 and 23.8% (p <0.001, d = 1.50 of peak forces during braking and propulsion sub-phases respectively; and (b increase of 41.8% in the braking (p <0.001, d = 1.41 and 12.3% in the propulsion contact times (p = 0.006, d = 0.75. The aquatic environment can be an alternative when one aims to reduce the load during the DJ contact; however, the longer duration increasing of contact sub-phases in water at hip immersion may compromise the proper functioning of the stretch-shortening cycle in water.
Shai, Nadav; Yifrach, Eden; van Roermund, Carlo W T; Cohen, Nir; Bibi, Chen; IJlst, Lodewijk; Cavellini, Laetitia; Meurisse, Julie; Schuster, Ramona; Zada, Lior; Mari, Muriel C; Reggiori, Fulvio M; Hughes, Adam L; Escobar-Henriques, Mafalda; Cohen, Mickael M; Waterham, Hans R; Wanders, Ronald J A; Schuldiner, Maya; Zalckvar, Einat
2018-01-01
The understanding that organelles are not floating in the cytosol, but rather held in an organized yet dynamic interplay through membrane contact sites, is altering the way we grasp cell biological phenomena. However, we still have not identified the entire repertoire of contact sites, their
The contact sport of rough surfaces
Carpick, Robert W.
2018-01-01
Describing the way two surfaces touch and make contact may seem simple, but it is not. Fully describing the elastic deformation of ideally smooth contacting bodies, under even low applied pressure, involves second-order partial differential equations and fourth-rank elastic constant tensors. For more realistic rough surfaces, the problem becomes a multiscale exercise in surface-height statistics, even before including complex phenomena such as adhesion, plasticity, and fracture. A recent research competition, the “Contact Mechanics Challenge” (1), was designed to test various approximate methods for solving this problem. A hypothetical rough surface was generated, and the community was invited to model contact with this surface with competing theories for the calculation of properties, including contact area and pressure. A supercomputer-generated numerical solution was kept secret until competition entries were received. The comparison of results (2) provides insights into the relative merits of competing models and even experimental approaches to the problem.
Improvements To Micro Contact Performance And Reliability
2016-12-22
layers approximately 0.2mm thick. The extruder is controlled in both the x and y directions by servo motors while the plate height is controlled with a...and contact area as the contacts pressed together and shared more surface area as the contacts elastically or plastically pressed together[164]. Figure...CrossRef 33. M. Braunovic, N. K. Myshkin, and V. V. Konchits, Electrical contacts: funda- mentals, applications and technology. CRC press , 2010, vol
LCLS Maximum Credible Beam Power
International Nuclear Information System (INIS)
Clendenin, J.
2005-01-01
The maximum credible beam power is defined as the highest credible average beam power that the accelerator can deliver to the point in question, given the laws of physics, the beam line design, and assuming all protection devices have failed. For a new accelerator project, the official maximum credible beam power is determined by project staff in consultation with the Radiation Physics Department, after examining the arguments and evidence presented by the appropriate accelerator physicist(s) and beam line engineers. The definitive parameter becomes part of the project's safety envelope. This technical note will first review the studies that were done for the Gun Test Facility (GTF) at SSRL, where a photoinjector similar to the one proposed for the LCLS is being tested. In Section 3 the maximum charge out of the gun for a single rf pulse is calculated. In Section 4, PARMELA simulations are used to track the beam from the gun to the end of the photoinjector. Finally in Section 5 the beam through the matching section and injected into Linac-1 is discussed
Non-conformal contact mechanical characteristic analysis on spherical components
Energy Technology Data Exchange (ETDEWEB)
Zhen-zhi, G.; Bin, H.; Zheng-ming, G.; Feng-mei, Y.; Jin, Q [The 2. Artillery Engineering Univ., Xi' an (China)
2017-03-15
Non-conformal spherical-contact mechanical problems is a three-dimensional coordination or similar to the coordination spherical contact. Due to the complexity of the problem of spherical-contact and difficulties of solving higher-order partial differential equations, problems of three-dimensional coordination or similar to the coordination spherical-contact is still no exact analytical method for solving. It is based on three-dimensional taper model is proposed a model based on the contour surface of the spherical contact and concluded of the formula of the contact pressure and constructed of finite element model by contact pressure distribution under the non-conformal spherical. The results shows spherical contact model can reflect non-conformal spherical-contacting mechanical problems more than taper-contacting model, and apply for the actual project.
Fragrance contact allergy in Iran.
Firooz, A; Nassiri-Kashani, M; Khatami, A; Gorouhi, F; Babakoohi, S; Montaser-Kouhsari, L; Davari, P; Dowlati, Y
2010-12-01
Fragrances are considered as one of the most common causes of allergic contact dermatitis. About 1-4% of the general population suffer from fragrance contact allergy (FCA). To determine the frequency of FCA and its clinical relevance in a sample of Iranian patients with history of contact and/or atopic dermatitis from January 2004 to December 2008. Standardized patch testing with 28-allergen screening series recommended by the German Contact Dermatitis Research Group and European Standard Series was used at six dermatological clinics in Iran. Fragrance allergens comprised of fragrance mix I (FM I), Myroxylon pereirae (MP; balsam of Peru), Lyral, turpentine and FM II. Fragrance contact allergy was detected in 7.2% of the patients. The frequency of positive reactions to FM I, MP and FM II were 3.7% (41/1105), 2.8% (32/1135) and 1.1% (3/267) respectively. 82.4% of the reactions to fragrance allergens were clinically relevant. The most common involved areas were hands (68.4%) and face (35.4%). Fragrance allergy predominantly affected women aged more than 40 years (P=0.008). Positive reaction to more than two allergens was significantly higher in FCA patients compared with other contact dermatitis patients (P<0.0001), and FM I, nickel and MP were the most frequent allergens in these patients. Despite less frequency of FCA in comparison with some European countries, its clinical relevance in Iranian patients seems to be high. It mostly affects the hands and the face predominantly in women aged more than 40 years. © 2010 The Authors. Journal compilation © 2010 European Academy of Dermatology and Venereology.
DEFF Research Database (Denmark)
Friis, Ulrik F; Menné, Torkil; Schwensen, Jakob F
2014-01-01
BACKGROUND: Irritant contact dermatitis (ICD) is a common diagnosis in patients with occupational contact dermatitis (OCD). Studies are lacking on the usefulness of material safety data sheets (MSDSs) in making the diagnosis of ICD. OBJECTIVE: To characterize irritant exposures leading...... to the diagnosis of occupational ICD (OICD), and to evaluate the occurrence of concomitant exposures to contact allergens. METHODS: We included 316 patients with suspected occupational hand dermatitis, referred to the Department of Dermato-Allergology, Copenhagen University Hospital Gentofte, Denmark during......), mechanical traumas (n = 19), and oils (n = 15). Exposure to specific irritant chemicals was found in 9 patients, and was identified from MSDSs/ingredients labelling in 8 of these patients. Review of MSDSs and ingredients labelling showed that 41 patients were exposed to 41 moderate to potent contact...
Contact angle distribution of particles at fluid interfaces.
Snoeyink, Craig; Barman, Sourav; Christopher, Gordon F
2015-01-27
Recent measurements have implied a distribution of interfacially adsorbed particles' contact angles; however, it has been impossible to measure statistically significant numbers for these contact angles noninvasively in situ. Using a new microscopy method that allows nanometer-scale resolution of particle's 3D positions on an interface, we have measured the contact angles for thousands of latex particles at an oil/water interface. Furthermore, these measurements are dynamic, allowing the observation of the particle contact angle with high temporal resolution, resulting in hundreds of thousands of individual contact angle measurements. The contact angle has been found to fit a normal distribution with a standard deviation of 19.3°, which is much larger than previously recorded. Furthermore, the technique used allows the effect of measurement error, constrained interfacial diffusion, and particle property variation on the contact angle distribution to be individually evaluated. Because of the ability to measure the contact angle noninvasively, the results provide previously unobtainable, unique data on the dynamics and distribution of the adsorbed particles' contact angle.
Katsaounis, Theodoros; Kotsovos, Konstantinos; Gereige, Issam; Al-Saggaf, Ahmed; Tzavaras, Athanasios
2017-01-01
A customized 2D computational tool has been developed to simulate bifacial rear local contact PERC type PV structures based on the numerical solution of the transport equations through the finite element method. Simulations were performed under various device material parameters and back contact geometry configurations in order to optimize bifacial solar cell performance under different simulated illumination conditions. Bifacial device maximum power output was also compared with the monofacial equivalent one and the industrial standard Al-BSF structure. The performance of the bifacial structure during highly diffused irradiance conditions commonly observed in the Middle East region due to high concentrations of airborne dust particles was also investigated. Simulation results demonstrated that such conditions are highly favorable for the bifacial device because of the significantly increased diffuse component of the solar radiation which enters the back cell surface.
Katsaounis, Theodoros
2017-09-18
A customized 2D computational tool has been developed to simulate bifacial rear local contact PERC type PV structures based on the numerical solution of the transport equations through the finite element method. Simulations were performed under various device material parameters and back contact geometry configurations in order to optimize bifacial solar cell performance under different simulated illumination conditions. Bifacial device maximum power output was also compared with the monofacial equivalent one and the industrial standard Al-BSF structure. The performance of the bifacial structure during highly diffused irradiance conditions commonly observed in the Middle East region due to high concentrations of airborne dust particles was also investigated. Simulation results demonstrated that such conditions are highly favorable for the bifacial device because of the significantly increased diffuse component of the solar radiation which enters the back cell surface.
Shoe allergic contact dermatitis.
Matthys, Erin; Zahir, Amir; Ehrlich, Alison
2014-01-01
Foot dermatitis is a widespread condition, affecting men and women of all ages. Because of the location, this condition may present as a debilitating problem to those who have it. Allergic contact dermatitis involving the feet is frequently due to shoes or socks. The allergens that cause shoe dermatitis can be found in any constituent of footwear, including rubber, adhesives, leather, dyes, metals, and medicaments. The goal of treatment is to identify and minimize contact with the offending allergen(s). The lack of product information released from shoe manufacturers and the continually changing trends in footwear present a challenge in treating this condition. The aim of this study is to review the current literature on allergic contact shoe dermatitis; clinical presentation, allergens, patch testing, and management will be discussed. PubMed and MEDLINE databases were used for the search, with a focus on literature updates from the last 15 years.
Takagaki, Shunsuke; Yamada, Hirofumi; Noda, Kei
2018-03-01
Contact effects in organic thin-film transistors (OTFTs) were examined by using our previously proposed parameter extraction method from the electrical characteristics of a single staggered-type device. Gate-voltage-dependent contact resistance and channel mobility in the linear regime were evaluated for bottom-gate/top-contact (BGTC) pentacene TFTs with active layers of different thicknesses, and for pentacene TFTs with contact-doped layers prepared by coevaporation of pentacene and tetrafluorotetracyanoquinodimethane (F4TCNQ). The extracted parameters suggested that the influence of the contact resistance becomes more prominent with the larger active-layer thickness, and that contact-doping experiments give rise to a drastic decrease in the contact resistance and a concurrent considerable improvement in the channel mobility. Additionally, the estimated energy distributions of trap density in the transistor channel probably reflect the trap filling with charge carriers injected into the channel regions. The analysis results in this study confirm the effectiveness of our proposed method, with which we can investigate contact effects and circumvent the influences of characteristic variations in OTFT fabrication.
A study on occlusal stability in shortened dental arches.
Sarita, Paulo T N; Kreulen, Cees M; Witter, Dick J; van't Hof, Martin; Creugers, Nico H J
2003-01-01
The aim of this study was to verify the hypothesis that shortened dental arches constitute a risk to occlusal stability. Using cluster samples, 725 subjects with shortened dental arches comprising intact anterior regions and zero to eight occluding pairs of posterior teeth and 125 subjects with complete dental arches were selected. Subjects with shortened dental arches were classified into eight categories according to arch length and symmetry. Parameters for occlusal stability were interdental spacing, occlusal tooth wear, occlusal contact of incisors in intercuspal position, and vertical and horizontal overlap. Additionally, tooth mobility and overeruption of unopposed teeth were assessed. Influence of independent variables (dental arch category, age, gender, and residence) on the parameters for occlusal stability was assessed by one-way ANOVA and Tukey's multiple range tests. Extreme shortened dental arches (zero to two pairs of occluding premolars) had significantly more interdental spacing, occlusal contact of incisors, and vertical overlap compared to complete dental arches. Occlusal wear and prevalence of mobile teeth were highest in these categories. The category with three to four occluding premolars had significantly more interdental spacing and, for the older age group, more anterior teeth in occlusal contact compared to complete dental arches. Age was consistently associated with increased changes in occlusal integrity. Signs of increased risk to occlusal stability seemed to occur in extreme shortened dental arches, whereas no such evidence was found for intermediate categories of shortened dental arches.
de Groot, Anton; Jagtman, Berend A; Woutersen, Marjolijn
2018-01-01
A case of allergic contact dermatitis from neem oil is presented. Neem oil (synonyms: Melia azadirachta seed oil [INCI name], nim oil, margosa oil) is a vegetable (fixed) oil obtained from the seed of the neem tree Azadirachta indica by cold pressing. Contact allergy to neem oil has been described
A thermodynamic model of contact angle hysteresis.
Makkonen, Lasse
2017-08-14
When a three-phase contact line moves along a solid surface, the contact angle no longer corresponds to the static equilibrium angle but is larger when the liquid is advancing and smaller when the liquid is receding. The difference between the advancing and receding contact angles, i.e., the contact angle hysteresis, is of paramount importance in wetting and capillarity. For example, it determines the magnitude of the external force that is required to make a drop slide on a solid surface. Until now, fundamental origin of the contact angle hysteresis has been controversial. Here, this origin is revealed and a quantitative theory is derived. The theory is corroborated by the available experimental data for a large number of solid-liquid combinations. The theory is applied in modelling the contact angle hysteresis on a textured surface, and these results are also in quantitative agreement with the experimental data.
13 CFR 107.840 - Maximum term of Financing.
2010-01-01
... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Maximum term of Financing. 107.840... COMPANIES Financing of Small Businesses by Licensees Structuring Licensee's Financing of An Eligible Small Business: Terms and Conditions of Financing § 107.840 Maximum term of Financing. The maximum term of any...
Contact fatigue in rolling-element bearings
CSIR Research Space (South Africa)
Fernandes, PJL
1997-06-01
Full Text Available to the "cyclone pitting effect" also observed in gear teeth \\[1\\]. The initiation of surface cracks under rollin~sliding contact can be significantly accelerated by the presence of stress concentration sites on the contact surf... formed by rolling and rollin~sliding contact fatigue may progress to form a more severe form of damage known as flaking \\[3\\]. This results in the formation of large, irregular pits which cause rapid deterioration...
Antibacterial surface design - Contact kill
Kaur, Rajbir; Liu, Song
2016-08-01
Designing antibacterial surfaces has become extremely important to minimize Healthcare Associated Infections which are a major cause of mortality worldwide. A previous biocide-releasing approach is based on leaching of encapsulated biocides such as silver and triclosan which exerts negative impacts on the environment and potentially contributes to the development of bacterial resistance. This drawback of leachable compounds led to the shift of interest towards a more sustainable and environmentally friendly approach: contact-killing surfaces. Biocides that can be bound onto surfaces to give the substrates contact-active antibacterial activity include quaternary ammonium compounds (QACs), quaternary phosphoniums (QPs), carbon nanotubes, antibacterial peptides, and N-chloramines. Among the above, QACs and N-chloramines are the most researched contact-active biocides. We review the engineering of contact-active surfaces using QACs or N-chloramines, the modes of actions as well as the test methods. The charge-density threshold of cationic surfaces for desired antibacterial efficacy and attempts to combine various biocides for the generation of new contact-active surfaces are discussed in detail. Surface positive charge density is identified as a key parameter to define antibacterial efficacy. We expect that this research field will continue to attract more research interest in view of the potential impact of self-disinfective surfaces on healthcare-associated infections, food safety and corrosion/fouling resistance required on industrial surfaces such as oil pipes and ship hulls.
Energy Technology Data Exchange (ETDEWEB)
NONE
1997-03-01
Development of high performance spin valves formed by amorphous magnetic layer and head-medium interface with nano-thickness molecular film for realizing an ultra-high density of 20 Gbit/in{sup 2} using contact recording. The giant magnetoresistance effect was investigated for spin valves using very thin amorphous magnetic layer. In amorphous-CoFeB/Cu/ Co spin valves, the maximum MR ratio of 6% was achieved at the thickness of the amorphous layer of 2 nm. The spin valves with the amorphous layer exhibit very good thermal stability. Design guideline for molecularly thin lubricant was established using newly derived lubrication equation considering lubricant porosity. Novel method for accurately measuring surface force due to molecularly thin lubricant was developed by using Michelson interferometry to detect cantilever displacement, which enabled two-dimensional transient force measurement. (NEDO)
Pinotti, Roberto
The problem of mass behavior after man's future contacts with other intelligences in the universe is not only a challenge for social scientists and political leaders all over the world, but also a cultural time bomb as well. In fact, since the impact of CETI (Contact with Extraterrestrial Intelligence) on human civilization, with its different cultures, might cause a serious socio-anthropological shock, a common and predetermined worldwide strategy is necessary in releasing the news after the contact, in order to keep possible manifestations of fear, panic and hysteria under control. An analysis of past studies in this field and of parallel historical situations as analogs suggests a definite "authority crisis" in the public as a direct consequence of an unexpected release of the news, involving a devastating "chain reaction" process (from both the psychological and sociological viewpoints) of anomie and maybe the collapse of today's society. The only way to prevent all this is to prepare the world's public opinion concerning contact before releasing the news, and to develop a long-term strategy through the combined efforts of scientists, political leaders, intelligence agencies and the mass media, in order to create the cultural conditions in which a confrontation with ETI won't affect mankind in a traumatic way. Definite roles and tasks in this multi-level model are suggested.
Pulsed Current Static Electrical Contact Experiment
National Research Council Canada - National Science Library
Jones, Harry N; Neri, Jesse M; Boyer, Craig N; Cooper, Khershed P; Meger, Robert A
2006-01-01
.... The voltage developed across the interface is directly related to the contact temperature and pressure, the number of a-spots, the thermophysical and mechanical properties of the contacting materials...
20 CFR 226.52 - Total annuity subject to maximum.
2010-04-01
... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false Total annuity subject to maximum. 226.52... COMPUTING EMPLOYEE, SPOUSE, AND DIVORCED SPOUSE ANNUITIES Railroad Retirement Family Maximum § 226.52 Total annuity subject to maximum. The total annuity amount which is compared to the maximum monthly amount to...
Review of prediction for thermal contact resistance
Institute of Scientific and Technical Information of China (English)
无
2010-01-01
Theoretical prediction research on thermal contact resistance is reviewed in this paper. In general, modeling or simulating the thermal contact resistance involves several aspects, including the descriptions of surface topography, the analysis of micro mechanical deformation, and the thermal models. Some key problems are proposed for accurately predicting the thermal resistance of two solid contact surfaces. We provide a perspective on further promising research, which would be beneficial to understanding mechanisms and engineering applications of the thermal contact resistance in heat transport phenomena.
Contact conditions in skin-pass rolling
DEFF Research Database (Denmark)
Kijima, Hideo; Bay, Niels
2007-01-01
The special contact conditions in skin-pass rolling of steel strip is analysed by studying plane strain upsetting of thin sheet with low reduction applying long narrow tools and dry friction conditions. An extended sticking region is estimated by an elasto-plastic FEM analysis of the plane strain...... upsetting. This sticking region causes a highly inhomogeneous elasto-plastic deformation with large influence of work-hardening and friction. A numerical analysis of skin-pass rolling shows the same contact conditions, i.e. an extended sticking region around the center of the contact zone. The calculated...... size of the sticking region with varying contact length and pressure/reduction is experimentally verified by plane strain upsetting tests measuring the local surface deformation of the work pieces after unloading....
Performance and Metastability of CdTe Solar Cells with a Te Back-Contact Buffer Layer
Moore, Andrew
Thin-film CdTe photovoltaics are quickly maturing into a viable clean-energy solution through demonstration of competitive costs and performance stability with existing energy sources. Over the last half decade, CdTe solar technology has achieved major gains in performance; however, there are still aspects that can be improved to progress toward their theoretical maximum efficiency. Perhaps equally valuable as high photovoltaic efficiency and a low levelized cost of energy, is device reliability. Understanding the root causes for changes in performance is essential for accomplishing long-term stability. One area for potential performance enhancement is the back contact of the CdTe device. This research incorporated a thin-film Te-buffer layer into the contact structure, between the CdTe and contact metal. The device performance and characteristics of many different back contact configurations were rigorously studied. CdTe solar cells fabricated with the Te-buffer contact showed short-circuit current densities and open-circuit voltages that were on par with the traditional back-contacts used at CSU. However, the Te-buffer contact typically produced 2% larger fill-factors on average, leading to greater conversation efficiency. Furthermore, using the Te buffer allowed for incorporation of 50% less Cu, which is used for p-type doping but is also known to decrease lifetime and stability. This resulted in an additional 3% fill-factor gain with no change in other parameters compared to the standard-Cu treated device. In order to better understand the physical mechanisms of the Te-buffer contact, electrical and material properties of the Te layer were extracted and used to construct a simple energy band diagram. The Te layer was found to be highly p-type (>1018 cm-3) and possess a positive valence-band offset of 0.35-0.40 eV with CdTe. An existing simulation model incorporating the Te-layer properties was implemented and validated by comparing simulated results of Cd
Metal Contacts to Gallium Arsenide.
Ren, Fan
1991-07-01
While various high performance devices fabricated from the gallium arsenide (GaAs) and related materials have generated considerable interest, metallization are fundamental components to all semiconductor devices and integrated circuits. The essential roles of metallization systems are providing the desired electrical paths between the active region of the semiconductor and the external circuits through the metal interconnections and contacts. In this work, in-situ clean of native oxide, high temperature n-type, low temperature n-type and low temperature p-type ohmic metal systems have been studied. Argon ion mill was used to remove the native oxide prior to metal deposition. For high temperature process n-type GaAs ohmic contacts, Tungsten (W) and Tungsten Silicide (WSi) were used with an epitaxial grown graded Indium Gallium Arsenide (InGaAs) layer (0.2 eV) on GaAs. In addition, refractory metals, Molybdenum (Mo), was incorporated in the Gold-Germanium (AuGe) based on n-type GaAs ohmic contacts to replace conventional silver as barrier to prevent the reaction between ohmic metal and chlorine based plasma as well as the ohmic metallization intermixing which degrades the device performance. Finally, Indium/Gold-Beryllium (In/Au-Be) alloy has been developed as an ohmic contact for p-type GaAs to reduce the contact resistance. The Fermi-level pinning of GaAs has been dominated by the surface states. The Schottky barrier height of metal contacts are about 0.8 V regardless of the metal systems. By using p-n junction approach, barrier height of pulsed C-doped layers was achieved as high as 1.4 V. Arsenic implantation into GaAs method was also used to enhance the barrier height of 1.6 V.
Are You Sure You Want to Contact Us? Quantifying the Leakage of PII via Website Contact Forms
Directory of Open Access Journals (Sweden)
Starov Oleksii
2016-01-01
Full Text Available The majority of commercial websites provide users the ability to contact them via dedicated contact pages. In these pages, users are typically requested to provide their names, email addresses, and reason for contacting the website. This effectively makes contact pages a gateway from being anonymous or pseudonymous, i.e., identified via stateful and stateless identifiers, to being eponymous. As such, the environment where users provide their personally identifiable information (PII has to be trusted and free from intentional and unintentional information leaks. In this paper, we report on the first large-scale study of PII leakage via contact pages of the 100,000 most popular sites of the web. We develop a reliable methodology for identifying and interacting with contact forms as well as techniques that allow us to discover the leakage of PII towards thirdparties, even when that information is obfuscated. Using these methods, we witness the leakage of PII towards third-parties in a wide range of ways, including the leakage through third-party form submissions, third-party scripts that collect PII information from a first-party page, and unintended leakage through a browser’s Referer header. To recover the lost control of users over their PII, we design and develop Formlock, a browser extension that warns the user when contact forms are using PII-leaking practices, and provides the ability to comprehensively lock-down a form so that a user’s details cannot be, neither accidentally, nor intentionally, leaked to third parties
Acrylate Systemic Contact Dermatitis.
Sauder, Maxwell B; Pratt, Melanie D
2015-01-01
Acrylates, the 2012 American Contact Dermatitis Society allergen of the year, are found in a range of products including the absorbent materials within feminine hygiene pads. When fully polymerized, acrylates are nonimmunogenic; however, if not completely cured, the monomers can be potent allergens.A 28-year-old woman is presented, who had her teeth varnished with Isodan (Septodont, Saint-Maur-des-Fossés, France) containing HEMA (2-hydroxyethyl methacrylate) with no initial reaction. Approximately 1 month later, the patient developed a genital dermatitis secondary to her feminine hygiene pads. The initial reaction resolved, but 5 months later, the patient developed a systemic contact dermatitis after receiving a second varnishing.The patient was dramatically patch test positive to many acrylates. This case demonstrates a reaction to likely unpolymerized acrylates within a feminine hygiene pad, as well as broad cross-reactivity or cosensitivity to acrylates, and possibly a systemic contact dermatitis with systemic re-exposure to unpolymerized acrylates.
Contact symmetries and Hamiltonian thermodynamics
International Nuclear Information System (INIS)
Bravetti, A.; Lopez-Monsalvo, C.S.; Nettel, F.
2015-01-01
It has been shown that contact geometry is the proper framework underlying classical thermodynamics and that thermodynamic fluctuations are captured by an additional metric structure related to Fisher’s Information Matrix. In this work we analyse several unaddressed aspects about the application of contact and metric geometry to thermodynamics. We consider here the Thermodynamic Phase Space and start by investigating the role of gauge transformations and Legendre symmetries for metric contact manifolds and their significance in thermodynamics. Then we present a novel mathematical characterization of first order phase transitions as equilibrium processes on the Thermodynamic Phase Space for which the Legendre symmetry is broken. Moreover, we use contact Hamiltonian dynamics to represent thermodynamic processes in a way that resembles the classical Hamiltonian formulation of conservative mechanics and we show that the relevant Hamiltonian coincides with the irreversible entropy production along thermodynamic processes. Therefore, we use such property to give a geometric definition of thermodynamically admissible fluctuations according to the Second Law of thermodynamics. Finally, we show that the length of a curve describing a thermodynamic process measures its entropy production
Ohmic contacts to semiconducting diamond
Zeidler, James R.; Taylor, M. J.; Zeisse, Carl R.; Hewett, C. A.; Delahoussaye, Paul R.
1990-10-01
Work was carried out to improve the electron beam evaporation system in order to achieve better deposited films. The basic system is an ion pumped vacuum chamber, with a three-hearth, single-gun e-beam evaporator. Four improvements were made to the system. The system was thoroughly cleaned and new ion pump elements, an e-gun beam adjust unit, and a more accurate crystal monitor were installed. The system now has a base pressure of 3 X 10(exp -9) Torr, and can easily deposit high-melting-temperature metals such as Ta with an accurately controlled thickness. Improved shadow masks were also fabricated for better alignment and control of corner contacts for electrical transport measurements. Appendices include: A Thermally Activated Solid State Reaction Process for Fabricating Ohmic Contacts to Semiconducting Diamond; Tantalum Ohmic Contacts to Diamond by a Solid State Reaction Process; Metallization of Semiconducting Diamond: Mo, Mo/Au, and Mo/Ni/Au; Specific Contact Resistance Measurements of Ohmic Contracts to Diamond; and Electrical Activation of Boron Implanted into Diamond.
Contact engineering for nano-scale CMOS
Hussain, Muhammad Mustafa
2012-09-10
High performance computation with longer battery lifetime is an essential component in our today\\'s digital electronics oriented life. To achieve these goals, field effect transistors based complementary metal oxide semiconductor play the key role. One of the critical requirements of transistor structure and fabrication is efficient contact engineering. To catch up with high performance information processing, transistors are going through continuous scaling process. However, it also imposes new challenges to integrate good contact materials in a small area. This can be counterproductive as smaller area results in higher contact resistance thus reduced performance for the transistor itself. At the same time, discovery of new one or two-dimensional materials like nanowire, nanotube, or atomic crystal structure materials, introduces new set of challenges and opportunities. In this paper, we are reviewing them in a synchronized fashion: fundamentals of contact engineering, evolution into non-planar field effect transistors, opportunities and challenges with one and two-dimensional materials and a new opportunity of contact engineering from device architecture perspective. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Occupational contact dermatitis in blue-collar workers
DEFF Research Database (Denmark)
Schwensen, Jakob F; Menné, Torkil; Veien, Niels K
2014-01-01
BACKGROUND: Blue-collar workers have a high risk of occupational contact dermatitis, but epidemiological studies are scarce. OBJECTIVES: To investigate allergic contact dermatitis in blue-collar workers with dermatitis registered by the Danish Contact Dermatitis Group. METHODS: A retrospective...... analysis of patch test data from 1471 blue-collar workers and 1471 matched controls tested between 2003 and 2012 was performed. A logistic regression was used to test for associations. RESULTS: The blue-collar workers often had occupational hand dermatitis (p dermatitis was less commonly......, and methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI). The following occupations were additionally identified as risk factors for contact sensitization to MCI/MI and MI, epoxy resins, and potassium dichromate, respectively: painting, construction work, and tile setting/terrazzo work. CONCLUSION: Contact allergy...
The Touch "Taboo" and the Art of Contact: An Exploration of Contact Improvisation for Prisoners
Houston, Sara
2009-01-01
The article examines the experience of participating in Contact Improvisation by male prisoners. It specifically focuses on issues of touch for this participant group and how inmates can learn different ways of acting from acquiring Contact skills, contributing to their rehabilitation. The paper looks at the culture in prisons that propagates a…
Maximum likely scale estimation
DEFF Research Database (Denmark)
Loog, Marco; Pedersen, Kim Steenstrup; Markussen, Bo
2005-01-01
A maximum likelihood local scale estimation principle is presented. An actual implementation of the estimation principle uses second order moments of multiple measurements at a fixed location in the image. These measurements consist of Gaussian derivatives possibly taken at several scales and/or ...
Moving contact lines on vibrating surfaces
Solomenko, Zlatko; Spelt, Peter; Scott, Julian
2017-11-01
Large-scale simulations of flows with moving contact lines for realistic conditions generally requires a subgrid scale model (analyses based on matched asymptotics) to account for the unresolved part of the flow, given the large range of length scales involved near contact lines. Existing models for the interface shape in the contact-line region are primarily for steady flows on homogeneous substrates, with encouraging results in 3D simulations. Introduction of complexities would require further investigation of the contact-line region, however. Here we study flows with moving contact lines on planar substrates subject to vibrations, with applications in controlling wetting/dewetting. The challenge here is to determine the change in interface shape near contact lines due to vibrations. To develop further insight, 2D direct numerical simulations (wherein the flow is resolved down to an imposed slip length) have been performed to enable comparison with asymptotic theory, which is also developed further. Perspectives will also be presented on the final objective of the work, which is to develop a subgrid scale model that can be utilized in large-scale simulations. The authors gratefully acknowledge the ANR for financial support (ANR-15-CE08-0031) and the meso-centre FLMSN for use of computational resources. This work was Granted access to the HPC resources of CINES under the allocation A0012B06893 made by GENCI.
Electrical Contacts in Monolayer Arsenene Devices.
Wang, Yangyang; Ye, Meng; Weng, Mouyi; Li, Jingzhen; Zhang, Xiuying; Zhang, Han; Guo, Ying; Pan, Yuanyuan; Xiao, Lin; Liu, Junku; Pan, Feng; Lu, Jing
2017-08-30
Arsenene, arsenic analogue of graphene, as an emerging member of two-dimensional semiconductors (2DSCs), is quite promising in next-generation electronic and optoelectronic applications. The metal electrical contacts play a vital role in the charge transport and photoresponse processes of nanoscale 2DSC devices and even can mask the intrinsic properties of 2DSCs. Here, we present a first comprehensive study of the electrical contact properties of monolayer (ML) arsenene with different electrodes by using ab initio electronic calculations and quantum transport simulations. Schottky barrier is always formed with bulk metal contacts owing to the Fermi level pinning (pinning factor S = 0.33), with electron Schottky barrier height (SBH) of 0.12, 0.21, 0.25, 0.35, and 0.50 eV for Sc, Ti, Ag, Cu, and Au contacts and hole SBH of 0.75 and 0.78 eV for Pd and Pt contacts, respectively. However, by contact with 2D graphene, the Fermi level pinning effect can be reduced due to the suppression of metal-induced gap states. Remarkably, a barrier free hole injection is realized in ML arsenene device with graphene-Pt hybrid electrode, suggestive of a high device performance in such a ML arsenene device. Our study provides a theoretical foundation for the selection of favorable electrodes in future ML arsenene devices.
Contact Dynamics of EHL Contacts under Time Varying Conditions
Venner, Cornelis H.; Popovici, G.; Wijnant, Ysbrand H.; Dalmaz, G.; Lubrecht, A.A.; Priest, M
2004-01-01
By means of numerical simulations of two situations with time varying operating conditions it is shown that the dynamic behaviour of Elasto-Hydrodynamically Lubricated contacts in terms of vibrations can be characterized as: Changes in the mutual approach lead to film thickness changes in the inlet
Microbial contamination of soft contact lenses & accessories in asymptomatic contact lens users
Directory of Open Access Journals (Sweden)
Deeksha V Thakur
2014-01-01
Full Text Available Background & objectives: With increasing use of soft contact lenses the incidence of contact lens induced infections is also increasing. This study was aimed to assess the knowledge of new and existing contact lens users about the risk of microbial contamination associated with improper use and maintenance of contact lenses, type of microbial flora involved and their potential to cause ophthalmic infections. Methods: Four samples each from 50 participants (n=200 were collected from the lenses, lens care solutions, lens care solution bottles and lens cases along with a questionnaire regarding their lens use. The samples were inoculated onto sheep blood agar, Mac Conkey′s agar and Sabouraud′s dextrose agar. Organisms were identified using standard laboratory protocols. Results: Overall rate of microbial contamination among the total samples was 52 per cent. The most and the least contaminated samples were found to be lens cases (62% and lens care solution (42%, respectively. The most frequently isolated contaminant was Staphylococcus aureus (21% followed by Pseudomonas species (19.5%. Majority (64% of the participants showed medium grade of compliance to lens cleaning practices. Rate of contamination was 100 and 93.75 per cent respectively in those participants who showed low and medium compliance to lens care practices as compared to those who had high level of compliance (43.75% ( p0 <0.05. Interpretation & conclusions: Lens care practices amongst the participants were not optimum which resulted into high level contamination. Hence, creating awareness among the users about the lens care practices and regular cleaning and replacements of lens cases are required.
Reliability growth of thin film resistors contact
Directory of Open Access Journals (Sweden)
Lugin A. N.
2010-10-01
Full Text Available Necessity of resistive layer growth under the contact and in the contact zone of resistive element is shown in order to reduce peak values of current flow and power dissipation in the contact of thin film resistor, thereby to increase the resistor stability to parametric and catastrophic failures.
Jet Fuel-Associated Occupational Contact Dermatitis.
Contestable, James J
2017-03-01
Occupational contact dermatitis is a ubiquitous problem. Sailors onboard U.S. Navy vessels are at high risk given the multitude of potential workplace exposures. Solvents, petrochemicals, and fuels are abundant and can cause irritant or allergic contact dermatitis. Symptoms of contact dermatitis can cause inability to work and, if chronic, may require a change in rating or job. Prevention of this issue requires patient education about the risks and correct personnel protective equipment. Even with preventative strategies in place, exposures and cases of contact dermatitis will occur. Treatment consists of topical steroids and immunomodulators, as well as barrier creams and emollients. The goal of treatment is to fully restore the skin's natural barrier and prevent further exposure. A classic case of jet fuel-associated contact dermatitis is reviewed. A literature review utilizing PubMed, Google Scholar, and Google Search was conducted to elucidate our understanding of this issue, current occupational health guidelines, preventative approaches, and treatments. This case report provides guidance and recommendations for providers who encounter contact dermatitis related to petrochemicals, such as jet fuel. The literature review revealed limited knowledge surrounding in vivo human skin effects of jet fuel, specifically JP-5. Even larger gaps were found in our understanding of, and guidelines for, protective modalities against jet fuel exposure and dermatitis. A case is presented to facilitate recognition of jet fuel contact dermatitis and guidance for treatment and prevention. Given our current limited knowledge and guidelines concerning protective equipment and skin protectants, multiple proposals for future studies are suggested. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.
International Nuclear Information System (INIS)
Wang, Yiping; Shi, Xusheng; Huang, Qunwu; Cui, Yong; Kang, Xue
2017-01-01
Highlights: • Direct-contact liquid film cooling dense-array solar cells was first proposed. • Average temperature was controlled well below 80 °C. • The maximum temperature difference was less than 10 °C. • The heat transfer coefficient reached up to 11.91 kW/(m"2·K) under 589X. - Abstract: This paper presented a new method of cooling dense-array solar cells in high concentrating photovoltaic system by direct-contact liquid film, and water was used as working fluid. An electric heating plate was designed to simulate the dense-array solar cells in high concentrating photovoltaic system. The input power of electric heating plate simulated the concentration ratios. By heat transfer experiments, the effect of water temperatures and flow rates on heat transfer performance was investigated. The results indicated that: the average temperature of simulated solar cells was controlled well below 80 °C under water temperature of 30 °C and flow rate of 300 L/h when concentration ratio ranged between 300X and 600X. The maximum temperature difference among temperature measurement points was less than 10 °C, which showed the temperature distribution was well uniform. The heat transfer coefficient reached up to 11.91 kW/(m"2·K) under concentration ratio of 589X. To improve heat transfer performance and obtain low average temperature of dense-array solar cells, lower water temperature and suitable water flow rate are preferred.
Association between atopic dermatitis and contact sensitization
DEFF Research Database (Denmark)
Hamann, Carsten R; Hamann, Dathan; Egeberg, Alexander
2017-01-01
BACKGROUND: It is unclear whether patients with atopic dermatitis (AD) have an altered prevalence or risk for contact sensitization. Increased exposure to chemicals in topical products together with impaired skin barrier function suggest a higher risk, whereas the immune profile suggests a lower...... contact dermatitis is suspected....... risk. OBJECTIVE: To perform a systematic review and meta-analysis of the association between AD and contact sensitization. METHODS: The PubMed/Medline, Embase, and Cochrane databases were searched for articles that reported on contact sensitization in individuals with and without AD. RESULTS...
Maximum gravitational redshift of white dwarfs
International Nuclear Information System (INIS)
Shapiro, S.L.; Teukolsky, S.A.
1976-01-01
The stability of uniformly rotating, cold white dwarfs is examined in the framework of the Parametrized Post-Newtonian (PPN) formalism of Will and Nordtvedt. The maximum central density and gravitational redshift of a white dwarf are determined as functions of five of the nine PPN parameters (γ, β, zeta 2 , zeta 3 , and zeta 4 ), the total angular momentum J, and the composition of the star. General relativity predicts that the maximum redshifts is 571 km s -1 for nonrotating carbon and helium dwarfs, but is lower for stars composed of heavier nuclei. Uniform rotation can increase the maximum redshift to 647 km s -1 for carbon stars (the neutronization limit) and to 893 km s -1 for helium stars (the uniform rotation limit). The redshift distribution of a larger sample of white dwarfs may help determine the composition of their cores
Contact conductance between graphene and quantum wires
International Nuclear Information System (INIS)
Li Haidong; Zheng Yisong
2009-01-01
The contact conductance between graphene and two quantum wires which serve as the leads to connect graphene and electron reservoirs is theoretically studied. Our investigation indicates that the contact conductance depends sensitively on the graphene-lead coupling configuration. When each quantum wire couples solely to one carbon atom, the contact conductance vanishes at the Dirac point if the two carbon atoms coupling to the two leads belong to the same sublattice of graphene. We find that such a feature arises from the chirality of the Dirac electron in graphene. Such a chirality associated with conductance zero disappears when a quantum wire couples to multiple carbon atoms. The general result irrelevant to the coupling configuration is that the contact conductance decays rapidly with the increase of the distance between the two leads. In addition, in the weak graphene-lead coupling limit, when the distance between the two leads is much larger than the size of the graphene-lead contact areas and the incident electron energy is close to the Dirac point, the contact conductance is proportional to the square of the product of the two graphene-lead contact areas, and inversely proportional to the square of the distance between the two leads
Moving droplets : The measurement of contact lines
Poelma, C.; Franken, M.J.Z.; Kim, H.; Westerweel, J.
2014-01-01
Contact lines are the locations where a gas, liquid and a solid meet. From everyday experience we know that such contact lines can be mobile, for example in the case of a water droplet sliding over a glass surface. However, the continuum description of the flow towards or away from a contact line
Hassan, Iffat; Rasool, Farhan; Akhtar, Saniya; Kamili, Afifa; Rather, Parvaiz; Kanth, Raihana; Bhat, Yasmeen; Rather, Shagufta; Mubashir, Syed; Yaseen, Atiya; Bashir, Safia
2018-01-01
Tulip, belonging to the genus Tulipa and family Liliaceae, is a spring-blooming perennial that grows from bulbs. Owing to manual handling, contact dermatitis can occur in professionals at any stage of the growth cycle of the tulip plant. To determine the clinical pattern of contact dermatitis resulting from tulip plant cultivation, and to assess contact allergy in workers coming into contact with this plant. One hundred and sixty-four tulip workers were screened, and 48 patients with suspected contact dermatitis were patch tested with 39 allergens, including haptens from the Indian baseline series, a plant series, and extracts from different parts of the tulip plant. Thirty-nine positive patch test reactions were observed in 21 patients. Seventeen patients showed positive reactions to either α-methylene-γ-butyrolactone or to tulip plant extract. Clinical relevance was observed for 13 of 17 positive patch test reactions. Contact dermatitis is an important health hazard in workers dealing with tulip bulbs. Further studies to identify and isolate other possible tulip allergens, and to quantify the amounts of allergens in different parts of the tulip plant, are recommended. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Surgical outcome in headache due to mucosal contact
International Nuclear Information System (INIS)
Goto, Fumiyuki; Yabe, Haruna; Ogawa, Kaoru
2010-01-01
Headaches is classified as primary and secondary, with secondary originating in head and neck conditions, the most important etiology being acute sinusitis. Headache due to mucosal contact, rarely encountered by otorhinolaryngologists, is an important secondary headache, whose criteria are defined by the International Classification of Headache Disorders to include intermittent pain localized in the periorbital and medial canthal or temporozygomatic regions, evidence that pain is attributable to mucosal contact and the presence of mucosal contact in the absence of acute rhinosinusitis, obtained using clinical examinations, nasal endoscopy, and/or computed tomography (CT). After mucosal contact is surgically corrected pain usually disappears permanently within 7 days. We reviewed mucosal contact headaches in 63 subjects undergoing nasal or paranasal surgery from April 2007 to March 2008. Of those 7 were diagnosed with headaches due to contact points in nasal mucosa, ranging from canthal to the temporozygomatic. The most common contact, between the middle turbinate and nasal septum, was seen in 6 of the 7. Surgery eliminated symptoms in 4 and ameliorated them in 3 indicating effective headache management. Subjects with severe headaches or localized periorbital and medial canthal pain regions, mucosal contact involvement is ruled out when CT allows no lesions. When mucosal contact headache is suspected, however surgery should be considered as a last resort. (author)
Revealing the Maximum Strength in Nanotwinned Copper
DEFF Research Database (Denmark)
Lu, L.; Chen, X.; Huang, Xiaoxu
2009-01-01
boundary–related processes. We investigated the maximum strength of nanotwinned copper samples with different twin thicknesses. We found that the strength increases with decreasing twin thickness, reaching a maximum at 15 nanometers, followed by a softening at smaller values that is accompanied by enhanced...
49 CFR 195.406 - Maximum operating pressure.
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false Maximum operating pressure. 195.406 Section 195.406 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS... HAZARDOUS LIQUIDS BY PIPELINE Operation and Maintenance § 195.406 Maximum operating pressure. (a) Except for...
Numerical Modeling of Electrical Contact Conductance of Rough Bodies
Directory of Open Access Journals (Sweden)
M. V. Murashov
2015-01-01
Full Text Available Since the beginning of the 20th century to the present time, efforts have been made to develop a model of the electrical contact conductance. The development of micro- and nanotechnologies make contact conductance problem more essential. To conduct borrowing from a welldeveloped thermal contact conductance models on the basis of thermal and electrical conductivity analogy is often not possible due to a number of fundamental differences. While some 3Dmodels of rough bodies deformation have been developed in one way or another, a 3D-model of the electrical conductance through rough bodies contact is still not. A spatial model of electrical contact of rough bodies is proposed, allows one to calculate the electrical contact conductance as a function of the contact pressure. Representative elements of the bodies are parallelepipeds with deterministic roughness on the contacting surfaces. First the non-linear elastic-plastic deformation of rough surface under external pressure is solved using the finite element software ANSYS. Then the solution of electrostatic problem goes on the same finite element mesh. Aluminum AD1 is used as the material of the contacting bodies with properties that account for cold work hardening of the surface. The numerical model is built within the continuum mechanics and nanoscale effects are not taken into account. The electrical contact conductance was calculated on the basis of the concept of electrical resistance of the model as the sum of the electrical resistances of the contacting bodies and the contact itself. It was assumed that there is no air in the gap between the bodies. The dependence of the electrical contact conductance on the contact pressure is calculated as well as voltage and current density distributions in the contact bodies. It is determined that the multi-asperity contact mode, adequate to real roughness, is achieved at pressures higher than 3MPa, while results within the single contact spot are
Maximum spectral demands in the near-fault region
Huang, Yin-Nan; Whittaker, Andrew S.; Luco, Nicolas
2008-01-01
The Next Generation Attenuation (NGA) relationships for shallow crustal earthquakes in the western United States predict a rotated geometric mean of horizontal spectral demand, termed GMRotI50, and not maximum spectral demand. Differences between strike-normal, strike-parallel, geometric-mean, and maximum spectral demands in the near-fault region are investigated using 147 pairs of records selected from the NGA strong motion database. The selected records are for earthquakes with moment magnitude greater than 6.5 and for closest site-to-fault distance less than 15 km. Ratios of maximum spectral demand to NGA-predicted GMRotI50 for each pair of ground motions are presented. The ratio shows a clear dependence on period and the Somerville directivity parameters. Maximum demands can substantially exceed NGA-predicted GMRotI50 demands in the near-fault region, which has significant implications for seismic design, seismic performance assessment, and the next-generation seismic design maps. Strike-normal spectral demands are a significantly unconservative surrogate for maximum spectral demands for closest distance greater than 3 to 5 km. Scale factors that transform NGA-predicted GMRotI50 to a maximum spectral demand in the near-fault region are proposed.
Grotevant, Harold D; Rueter, Martha; Von Korff, Lynn; Gonzalez, Christopher
2011-05-01
This study examined the relation between three variables related to adoptive family relationships (post-adoption contact between adoptive and birth family members, adoption communicative openness, and satisfaction with contact) and adoptee externalizing behavior in adolescence and emerging adulthood. The study included 190 families of infant-placed, domestic adoptees during childhood, adolescence, and emerging adulthood. Structural equation modeling (SEM) was used to analyze predictors of externalizing behavior from contact (adoptive parents and adolescent reports), adoption communicative openness (adoptive mothers), and satisfaction with contact (adoptive parents and adolescent). Externalizing behavior showed moderate stability across childhood, adolescence, and emerging adulthood. Contact and adoption communicative openness were related to each other, but not to externalizing behaviors in adolescence or emerging adulthood. Controlling for the effect of Childhood Externalizing, adoptive families most satisfied with contact reported relative declines in adoptee externalizing behavior during adolescence compared to those in less satisfied families. Satisfaction was also indirectly associated with Emerging Adult Externalizing, through its effect on Adolescent Externalizing. Although contact and adoption communicative openness were highly correlated with each other, neither was related to adoptees' externalizing behavior in adolescence or emerging adulthood. Family-level satisfaction with contact was more predictive of externalizing outcomes. © 2010 The Authors. Journal of Child Psychology and Psychiatry © 2010 Association for Child and Adolescent Mental Health.
Directory of Open Access Journals (Sweden)
Wenjian Xu
Full Text Available The prevalence of childhood sexual abuse (CSA is high among Western men who have sex with men (MSM, and CSA is associated with certain socio-demographic variables and with human immunodeficiency virus (HIV status. Little is known about CSA among Chinese MSM; therefore, we explored the prevalence and frequency of non-contact (e.g., sexual invitations, exhibitionism and contact (e.g., intercourse, genital contact forms of CSA in an Internet-based sample of MSM in China. We also examined the associations between the participants' socio-demographic characteristics and HIV status, and their histories of CSA.We surveyed MSM from 30 Chinese provinces in 2014-2015; 1,030 (mean age = 25.15 years, SD = 6.32 and 1,020 (mean age = 25.05 years, SD = 5.95 respondents were eligible for inclusion in the non-contact and contact CSA groups, respectively.Prevalence of non-contact and contact CSA was 36.2% and 29.8%, respectively; 20.4% and 15.0% had experienced non-contact and contact CSA ≥ 3 times, respectively. Most respondents were young adults, well educated, single, had never "come out," and self-identified as gay or bisexual men. Univariate analyses showed that respondents who had experienced contact CSA were more likely to be HIV-positive than those who had never experienced contact CSA. Multivariate analyses showed that non-contact CSA was associated with less education, being in a relationship with a woman or a man, and having "come out." Contact CSA was associated with less education, higher income, and being in a relationship with a man. Respondents who had experienced non-contact CSA ≥ 3 times were more likely to be less educated, "out," and to be in a relationship with a woman or a man. Respondents who had experienced contact CSA ≥ 3 times were more likely to be less educated and to be in a relationship with a man.It is necessary to pay closer attention to CSA among MSM and other sexual minorities in China.
Maximum allowable load on wheeled mobile manipulators
International Nuclear Information System (INIS)
Habibnejad Korayem, M.; Ghariblu, H.
2003-01-01
This paper develops a computational technique for finding the maximum allowable load of mobile manipulator during a given trajectory. The maximum allowable loads which can be achieved by a mobile manipulator during a given trajectory are limited by the number of factors; probably the dynamic properties of mobile base and mounted manipulator, their actuator limitations and additional constraints applied to resolving the redundancy are the most important factors. To resolve extra D.O.F introduced by the base mobility, additional constraint functions are proposed directly in the task space of mobile manipulator. Finally, in two numerical examples involving a two-link planar manipulator mounted on a differentially driven mobile base, application of the method to determining maximum allowable load is verified. The simulation results demonstrates the maximum allowable load on a desired trajectory has not a unique value and directly depends on the additional constraint functions which applies to resolve the motion redundancy
Robust Maximum Association Estimators
A. Alfons (Andreas); C. Croux (Christophe); P. Filzmoser (Peter)
2017-01-01
textabstractThe maximum association between two multivariate variables X and Y is defined as the maximal value that a bivariate association measure between one-dimensional projections αX and αY can attain. Taking the Pearson correlation as projection index results in the first canonical correlation
Contact Lens Visual Rehabilitation in Keratoconus and Corneal Keratoplasty
Directory of Open Access Journals (Sweden)
Yelda Ozkurt
2012-01-01
Full Text Available Keratoconus is the most common corneal distrophy. It’s a noninflammatory progressive thinning process that leads to conical ectasia of the cornea, causing high myopia and astigmatism. Many treatment choices include spectacle correction and contact lens wear, collagen cross linking, intracorneal ring segments implantation and finally keratoplasty. Contact lenses are commonly used to reduce astigmatism and increase vision. There are various types of lenses are available. We reviewed soft contact lenses, rigid gas permeable contact lenses, piggyback contact lenses, hybrid contact lenses and scleral-semiscleral contact lenses in keratoconus management. The surgical option is keratoplasty, but even after sutur removal, high astigmatism may stil exists. Therefore, contact lens is an adequate treatment option to correct astigmatism after keratoplasty.
Contact activation of blood-plasma coagulation
Golas, Avantika
Surface engineering of biomaterials with improved hemocompatibility is an imperative, given the widespread global need for cardiovascular devices. Research summarized in this dissertation focuses on contact activation of FXII in buffer and blood plasma frequently referred to as autoactivation. The extant theory of contact activation imparts FXII autoactivation ability to negatively charged, hydrophilic surfaces. According to this theory, contact activation of plasma involves assembly of proteins comprising an "activation complex" on activating surfaces mediated by specific chemical interactions between complex proteins and the surface. This work has made key discoveries that significantly improve our core understanding of contact activation and unravel the existing paradigm of plasma coagulation. It is shown herein that contact activation of blood factor XII (FXII, Hageman factor) in neat-buffer solution exhibits a parabolic profile when scaled as a function of silanized-glass-particle activator surface energy (measured as advancing water adhesion tension t°a=g° Iv costheta in dyne/cm, where g°Iv is water interfacial tension in dyne/cm and theta is the advancing contact angle). Nearly equal activation is observed at the extremes of activator water-wetting properties --36 moderated by adsorption of plasma proteins unrelated to coagulation through an "adsorption-dilution" effect that blocks FXII contact with hydrophobic activator surfaces. The adsorption-dilution effect explains the apparent specificity for hydrophilic activators pursued by earlier investigators. Finally a comparison of FXII autoactivation in buffer, serum, protein cocktail, and plasma solutions is shown herein. Activation of blood plasma coagulation in vitro by contact with material surfaces is demonstrably dependent on plasma-volume-to-activator-surface-area ratio. However, activation of factor XII dissolved in buffer, protein cocktail, heat-denatured serum, and FXI deficient plasma does not
Ma, Yue; Yin, Fei; Zhang, Tao; Zhou, Xiaohua Andrew; Li, Xiaosong
2016-01-01
Spatial scan statistics are widely used in various fields. The performance of these statistics is influenced by parameters, such as maximum spatial cluster size, and can be improved by parameter selection using performance measures. Current performance measures are based on the presence of clusters and are thus inapplicable to data sets without known clusters. In this work, we propose a novel overall performance measure called maximum clustering set-proportion (MCS-P), which is based on the likelihood of the union of detected clusters and the applied dataset. MCS-P was compared with existing performance measures in a simulation study to select the maximum spatial cluster size. Results of other performance measures, such as sensitivity and misclassification, suggest that the spatial scan statistic achieves accurate results in most scenarios with the maximum spatial cluster sizes selected using MCS-P. Given that previously known clusters are not required in the proposed strategy, selection of the optimal maximum cluster size with MCS-P can improve the performance of the scan statistic in applications without identified clusters.
Homotopy classification of contact foliations on open contact manifolds
Indian Academy of Sciences (India)
64
Let ξt, t ∈ [0, 1] be a continuous family of contact structures defined by the ... here is based on ideas that can be found in [5] and [8] and may be known to experts. ..... the bigger rectangle represents the set U ×Iε1 and the central dotted line.
Estimation of contact resistance in proton exchange membrane fuel cells
Energy Technology Data Exchange (ETDEWEB)
Zhang, Lianhong; Liu, Ying; Song, Haimin; Wang, Shuxin [School of Mechanical Engineering, Tianjin University, 92 Weijin Road, Nankai District, Tianjin 300072 (China); Zhou, Yuanyuan; Hu, S. Jack [Department of Mechanical Engineering, The University of Michigan, Ann Arbor, MI 48109-2125 (United States)
2006-11-22
The contact resistance between the bipolar plate (BPP) and the gas diffusion layer (GDL) is an important factor contributing to the power loss in proton exchange membrane (PEM) fuel cells. At present there is still not a well-developed method to estimate such contact resistance. This paper proposes two effective methods for estimating the contact resistance between the BPP and the GDL based on an experimental contact resistance-pressure constitutive relation. The constitutive relation was obtained by experimentally measuring the contact resistance between the GDL and a flat plate of the same material and processing conditions as the BPP under stated contact pressure. In the first method, which was a simplified prediction, the contact area and contact pressure between the BPP and the GDL were analyzed with a simple geometrical relation and the contact resistance was obtained by the contact resistance-pressure constitutive relation. In the second method, the contact area and contact pressure between the BPP and GDL were analyzed using FEM and the contact resistance was computed for each contact element according to the constitutive relation. The total contact resistance was then calculated by considering all contact elements in parallel. The influence of load distribution on contact resistance was also investigated. Good agreement was demonstrated between experimental results and predictions by both methods. The simplified prediction method provides an efficient approach to estimating the contact resistance in PEM fuel cells. The proposed methods for estimating the contact resistance can be useful in modeling and optimizing the assembly process to improve the performance of PEM fuel cells. (author)
Directory of Open Access Journals (Sweden)
Valentin L. Popov
2014-04-01
Full Text Available The Method of Dimensionality Reduction (MDR is a method of calculation and simulation of contacts of elastic and viscoelastic bodies. It consists essentially of two simple steps: (a substitution of the three-dimensional continuum by a uniquely defined one-dimensional linearly elastic or viscoelastic foundation (Winkler foundation and (b transformation of the three-dimensional profile of the contacting bodies by means of the MDR-transformation. As soon as these two steps are completed, the contact problem can be considered to be solved. For axial symmetric contacts, only a small calculation by hand is required which does not exceed elementary calculus and will not be a barrier for any practically-oriented engineer. Alternatively, the MDR can be implemented numerically, which is almost trivial due to the independence of the foundation elements. In spite of their simplicity, all the results are exact. The present paper is a short practical guide to the MDR.